Omega Engineering Daq 12 Users Manual Word Pro 12.lwp
DAQ-12 M3453
DAQ-12 to the manual ec8ddff5-0c4f-50b4-c55e-fa369bad8d54
2015-02-02
: Omega-Engineering Omega-Engineering-Daq-12-Users-Manual-439843 omega-engineering-daq-12-users-manual-439843 omega-engineering pdf
Open the PDF directly: View PDF .
Page Count: 31
Download | |
Open PDF In Browser | View PDF |
(1*,1((5,1* ,1& DAQ-12 Data Acquisition Adapter For 16 bit ISA compatible machines Users Manual INTERFACE CARDS FOR PERSONAL COMPUTERS OMEGA ENGINEERING, INC. One Omega Drive P.O. Box 4047 Stamford, CT 06907-4047 http://www.dasieee.com TEL: (203) 359-1660 FAX: (203) 359-7700 Toll free: 1-800-826-6342 E-mail: das@omega.com WARRANTY/DISCLAIMER OMEGA ENGINEERING, INC., warrants this unit to be free of defects in materials and workmanship for a period of 13 months from the date of purchase. OMEGA warranty adds an additional one (1) month grace period to the normal one (1) year product warranty to cover shipping and handling time. This ensures that OMEGA’s customers receive maximum coverage on each product. If the unit should malfunction, it must be returned to the factory for evaluation. OMEGA’s Customer Service Department will issue an Authorized Return (AR) number immediately upon phone or written request. Upon examination by OMEGA, if the unit is found to be defective it will be repaired or replaced at no charge. OMEGA’s warranty does not apply to defects resulting from any action of the purchaser, including but not limited to mishandling, improper interfacing, operation outside design limits, improper repair or unauthorized modification. This WARRANTY is VOID if the unit shows evidence of having been tampered with or shows evidence of being damaged as a result of excessive corrosion; or current, heat, moisture or vibration; improper specification; misapplication; misuse or other operating conditions outside of OMEGA’s control. Components which wear are not warranted, including but not limited to contact points, fuses and triacs. OMEGA is pleased to offer suggestions on the use of its various products. However, OMEGA neither assumes responsibility for any omissions or errors nor assumes liability for any damages that result from the use of its products in accordance with information provided from OMEGA, either verbal or written. OMEGA warrants only that the parts manufactured by it will be as specified and free of defects. OMEGA MAKES NO OTHER WARRANTIES OR REPRESENTATIONS OF ANY KIND WHATSOEVER, EXPRESSED OR IMPLIED, EXCEPT THAT OF TITLE, AND ALL IMPLIED WARRANTIES INCLUDING ANY WARRANTY OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE ARE HEREBY DISCLAIMED. LIMITATION OF LIABILITY: The remedies of purchaser set forth herein are exclusive and the total liability of OMEGA with respect to this order, whether based on contract, warranty, negligence, indemnification, strict liability or otherwise, shall not exceed the purchase price of the component upon which liability is based. In no event shall OMEGA be liable for consequential, incidental or special damages. CONDITIONS: Equipment sold by OMEGA is not intended to be used, nor shall it be used: (1) as a “Basic Component” under 10 CFR 21 (NRC), used in or with any nuclear installation or activity, medical application or used on humans. Should any Product(s) be used in or with any nuclear installation or activity, medical application, used on humans or misused in any way, OMEGA assumes no responsibility as set forth in our basic WARRANTY/DISCLAIMER language, and additionally, purchaser will indemnify OMEGA and hold OMEGA harmless from any liability or damage whatsoever arising out of the use of the Product(s) in such a manner. RETURN REQUESTS/INQUIRIES Direct all warranty and repair requests/inquiries to the OMEGA Customer Service Department. BEFORE RETURNING ANY PRODUCT(S) TO OMEGA, PURCHASER MUST OBTAIN AN AUTHORIZED RETURN (AR) NUMBER FROM OMEGA’S CUSTOMER SERVICE DEPARTMENT (IN ORDER TO AVOID PROCESSING DELAYS). THE ASSIGNED NUMBER SHOULD THEN BE MARKED ON THE OUTSIDE OF THE RETURN PACKAGE AND ON ANY CORRESPONDENCE. THE PURCHASER IS RESPONSIBLE FOR SHIPPING CHARGES, FREIGHT, INSURANCE AND PROPER PACKAGING TO PREVENT BREAKAGE IN TRANSIT. FOR WARRANTY RETURNS, please have the following information available BEFORE contacting OMEGA: (1) P.O. Number under which the product was purchased, (2) Model and serial number of the product under warranty, and (3) Repair instructions and/or specific problems relative to the product. FOR NON-WARRANTY REPAIRS, consult OMEGA for current repair charges. Have the following information available BEFORE contacting OMEGA: (1) P.O. Number to cover the cost of the repair, (2) Model and serial number of the product, and (3) Repair instructions relative to the product. OMEGA’s policy is to make running changes, not model changes, whenever an improvement is possible. This affords our customers the latest in technology and engineering. OMEGA is a registered trademark of OMEGA ENGINEERING, INC. © Copyright 1999 OMEGA ENGINEERING, INC. All rights reserved. This document may not be copied, photocopied, reproduced, translated or reduced to any electronic medium or machine readable form, in whole or in part, without prior written consent of OMEGA ENGINEERING, INC. DAQ-12 Users Manual 2 Declaration of Conformity Manufacturer's Name: Omega Engineering, Inc. Manufacturer’s Address: One Omega Drive Stamford, CT 06907-0047 Application of Council Directive: 89/336/EEC Standards to which Conformity is Declared: * EN50081-2 (EN55022, EN60555-2, EN60555-3) * EN50082-1 (IEC 801-2, IEC 801-3, & IEC 801-4) Type of Equipment: Information Technology Equipment Equipment Class: Light Industrial Equipment Product Name: ISA Data Acquisition Card Model Number : DAQ-12 DAQ-12 Users Manual 3 OMEGAnet On-line Service: http://www.omega.com Internet e-mail: info@omega.com Servicing North America: USA: ISO 9001 Certified Canada: One Omega Drive, Box 4047 Stamford, CT 06907-0047 Tel: (203) 359-1660 E-mail: info@omega.com 976 Bergar Laval (Quebec) H7L 5A1 Tel: (514) 856-6928 E-mail: info@omega.com FAX: (203) 359-7700 FAX: (514) 856-6886 For immediate technical or application assistance: USA and Canada: Sales Service: 1-800-826-6342 / 1-800-TC-OMEGA SM Customer Service: 1-800-622-2378/ 1-800-622-BEST SM Engineering Service: 1-800-872-9436 / 1-800-USA-WHEN SM TELEX: 996404 EASYLINK: 62968934 CABLE: OMEGA Mexico and Latin America: Tel: (001) 800-826-6342 En Espanol: (001) 203-359-7803 FAX: (001) 203-359-7807 E-mail: espanol@omega.com Servicing Europe: Benelux: Postbus 8034, 1180 LA Amstelveen, The Netherlands Tel: (31) 20 6418405 Toll Free in Benelux: 0800 0993344 E-mail: nl@omega.com Czech Republic: ul.Rude armady 1868, 733 01 Karvina-Hraniee Tel: 42 (69) 6311899 FAX: 42 (69) 6311114 Toll Free: 0800-1-66342 E-mail: czech@omega.com France: 9, rue Denis Papin, 78190 Trappes Tel: (33) 130-621-400 Toll Free in France: 0800-4-06342 E-mail: france@omega.com Germany/Austria: Daimlerstrasse 26, D-75392 Deckenpfronn, Germany Tel: 49 (07056) 3017 Toll Free in Germany: 0130 11 21 66 E-mail: germany@omega.com DAQ-12 Users Manual 4 United Kingdom: ISO 9002 Certified One Omega Drive, River Bend Technology Drive Northbank, Irlam, Manchester M44 5EX, England Tel: 44 (161) 777-6611 FAX: 44 (161) 777-6622 Toll Free in England: 0800-488-488 E-mail: info@omega.co.uk It is the policy of OMEGA to comply with all worldwide safety and EMC/EMI regulations that apply. OMEGA is constantly pursuing certification of it’s products to the European New Approach Directives. OMEGA will add the CE mark to every appropriate device upon certification. The information contained in this document is believed to be correct but OMEGA Engineering, Inc. accepts no liability for any errors it contains, and reserves the right to alter specifications without notice. WARNING: These products are not designed for use in, and should not be used for, patient connected applications. DAQ-12 Users Manual 5 Table of Contents 1. Introduction ......................................................... 8 1.1 Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 1.2 DAQ-12 Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9 2. Circuit Board Description and Configuration .............. 2.1 Analog to Digital Converter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.2 Digital to Analog Converters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.3 Digital Input/Output . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.4 Base Address . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.5 Clock Selection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.5.1 Internal Clock . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.5.2 External Clock . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.6 Trigger Selection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.7 Direct Memory Access . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.8 Interrupts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.8.1 External Interrupt . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3. External Connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4. Register Description and Programming . . . . . . . . . . . . . . . . . . . . . 4.1 Register Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4.1.1 4.1.2 4.1.3 4.1.4 4.1.5 4.1.6 4.1.7 4.1.8 4.1.9 Control Word Register . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Start of Conversion Register . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A/D Converter Data Register . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . D/A Converter 0 Register . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . D/A Converter 1 Register . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Clock Rate Register (low word) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Clock Rate Register (high word) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Multi-Function Timer Register . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8254 Control Word/Status Register . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4.2 Programming the 8254 Counter/Timer . . . . . . . . . . . . . . . . . . . . . . . . . . . . DAQ-12 Users Manual 10 10 14 16 16 17 18 19 20 21 22 22 23 25 25 25 27 27 28 28 28 28 28 28 29 6 List of Figures and Tables Figure 2-1. Jumper J1 Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Figure 2-2. Jumper J7 Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Figure 2-3. Jumper J6 Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Figure 2-4. Jumper J4 Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Figure 2-5. I/O Base Address Selection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Figure 2-6. Jumper J3 Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Figure 2-7. Sampling Rate External Clock Pulses . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Figure 2-8. Pre-Divider External Clock Pulses . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Figure 2-9. Jumper J2 Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Figure 2-10. Jumpers J8 and J9 Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Figure 2-11. Jumpers J10 and J11 Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Figure 3-1. 62 Pin Connector Diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Table 2-1. Recommended Input Ranges and Gain Settings . . . . . . . . . . . . . . . . . . . . . . . . . Table 2-2. A/D Conversion Format Examples . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Table 2-3. D/A Converter Mode Selection Options . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Table 4-1. DAQ-12 Address Map . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . DAQ-12 Users Manual 10 11 13 14 16 17 19 20 20 21 22 23 12 14 15 25 7 1. Introduction The DAQ-12 is a high speed data acquisition adapter for IBM AT and compatible machines offering eight differential analog input channels with 16-bit resolution, two analog output channels with 12-bit resolution and four digital input/output lines. Other features of the DAQ-12 include: Analog to Digital Converter 200 KHz maximum sampling rate Bipolar input ranges from ±10mV to ±10 volts Unipolar input ranges from 20mV to 10 volts Programmable gain selection Two DMA channels for continuous acquisition Internal or external clock and trigger Digital to Analog Converters Two independent analog output channels Output ranges of 0 to ±5 volts Internal or external voltage reference Two DMA channels for continuous output Other Features Interrupt on one of four sources including an external interrupt input High density D-62 connector for reduced noise 1.1 Installation 1. Configure the DAQ-12 utilizing the instructions in Chapter 2: Circuit Board Description and Configuration. 2. Ensure that power is not applied to the computer system. 3. Remove the cover according to the instructions provided by the system manufacturer. 4. Insert the DAC-16 into any vacant ISA expansion slot. The board is secured to the slot by installing the Option Retaining Bracket (ORB) screw. 5. Replace the system cover per manufacturer instructions. DAQ-12 Users Manual 8 1.2 DAQ-12 Specifications Bus Interface: ISA 16-bit I/O Address Range: 0000H - FFFFH Interrupt Levels: IRQ 2, 3, 4. 5, 6, 7, 10, 11, 12, 14, 15 DMA Levels: DRQ 5, 6, 7 DACK 5, 6, 7 Power Requirements: Power Supply I(t) I(ms) -5 volts --- --- +5 volts 1069.0 mA 1204.9mA -12 volts --- --- +12 volts 374.9 mA 491.4mA I(t) = Typical Current / I(ms) = Maximum Statisical Current DAQ-12 Users Manual 9 2. Circuit Board Description and Configuration The base address of the DAQ-12 is selected using switches SW1 and SW2. The operating mode of the DAQ-12 is controlled by jumpers J1 through J7, while DMA and interrupt selections are set with jumpers J8 through J11. Connections to external equipment are made through the high density 62-pin connector CN1. 2.1 Analog to Digital Converter The analog to digital (A/D) section of the DAQ-12 accepts up to 8 differential or 16 single ended inputs from the D-62 connector. These inputs pass through a multiplexer circuit which selects the channel to be converted. The selected input is then amplified and presented to the A/D converter to be digitized. The digital output of the A/D is latched into a buffer to be read by the computer. The multiplexer circuit (MUX) selects one of the analog input channels to be input to the A/D converter. The typical characteristics of the multiplexer circuit are: switching time: 0.5 us settling time: 3.0 us Before operating the DAQ-12, the multiplexer circuit must be configured to accept either differential or single-ended analog inputs. Single-ended mode measures the voltage difference between the input signal and the analog ground reference of the DAQ-12 (e.g. CH0+ and ground) while differential mode measures the voltage difference between two input signals (e.g. CH0+ and CH0-). Jumper J1 is used to configure the DAQ-12 for either single ended or differential inputs a shown in Figure 2-1. Once configured, the input channel is software selectable through the control word register. 5 6 7 8 1 2 3 4 8 Differential Channels J1 5 6 7 8 1 2 3 4 16 Single Ended Channels Figure 2-1. Jumper J1 Configuration DAQ-12 Users Manual 10 The amplifier stage of the A/D converter circuit performs two functions: (1) amplifies low level input signals and (2) converts this input signal into a voltage range acceptable to the A/D converter. Seven gain levels are software selectable for the amplifier stage of the A/D circuit. To support high level input signals, the DAQ-12 provides input gain selections of 1, 2, 4 and 8. For signals requiring greater amplification, the DAQ-12 provides input gains of 1, 10, 100 and 500. The gain setting is determined by the value written to the gain control register. In order to provide a full +10 volt input range and for greater overall versatility, the DAQ-12 is equipped with a 'divide by 2' pre-scaling circuit. With the pre-scaler enabled, the resultant high level input gain selections become ½, 1, 2 and 4 and the low level input gain selections become ½, 5, 50 and 250. Figure 2-2 illustrates jumper J7 (Pre-scaler) configuration options. NOTE: The unipolar / bipolar input selection is controlled by the A/D converter and is selected independent of the single-ended or differential input mode configuration of the multiplexer and amplifier circuits. J7 Disable Pre-Scaler (factory default) Enable Pre-Scaler Figure 2-2. Jumper J7 Configuration DAQ-12 Users Manual 11 Table 2-1 details the available gain settings and resulting input ranges for the various input configurations. Note that the 'gain byte' field in Table 2-1 is the value written to the DAQ-12's gain control register. (* indicates unipolar mode not available with gain of ½ ). Maximum Input Voltage Unipolar / Bipolar +10/±5 +1/±0.5 +0.1/±0.05 +0.02/±0.01 +10/±5 +5/±2.5 Amplifier Gain 1 10 100 500 1 2 J7 --1-2 1-2 1-2 1-2 1-2 1-2 Gain Byte (HEX) --00 01 02 03 80 81 +2.5/±1.25 +1.25/±0.625 4 8 1-2 1-2 82 83 N/A*/±10 +2/±1 +0.2/±0.1 +0.04/±0.02 N/A*/ ±10 +10/ ±5 +5/ ±2.5 +2.5/ ±1.25 ½ 5 50 250 ½ 1 2 4 2-3 2-3 2-3 2-3 2-3 2-3 2-3 2-3 00 01 02 03 80 81 82 83 Table 2-1. Recommended Input Ranges and Gain Settings DAQ-12 Users Manual 12 The final stage of the A/D converter circuit is the A/D converter IC. The converter must be configured for unipolar or bipolar input voltages as shown in Figure 2-3. When configured for unipolar operation, the analog input multiplied by the gain setting must be in the range of 0 volts (analog ground) to +10 volts. When configured for bipolar operation, the analog input multiplied by the gain setting must be in the range of -5 volts to +5 volts. J6 J6 4 5 6 4 5 6 1 2 3 1 2 3 Bipolar Unipolar Figure 2-3. Jumper J6 Configuration WARNING: The user must ensure that the maximum input voltage multiplied by the amplifier gain does not exceed the range of 0 to +10 volts for unipolar operation or -5 to +5 volts for bipolar operation. Although the A/D converter produces 12-bit digital 'codes' to represent the input voltage, the DAQ-12 converts these 'codes' into standard 16-bit signed integer values before returning them to the PC. When the A/D converter is configured for unipolar operation, the DAQ-12 returns values in the range of 0 to 4095. When configured for bipolar operation, values in the range of -2048 to +2047 are returned. In order to calculate the actual input voltage from the value provided by the DAQ-12, the user must know the configuration (unipolar / bipolar) and the gain setting used to acquire the data. Given this information, the input voltage can be calculated using the following equations: Unipolar mode: input = CODE * 4096 10V GAIN Bipolar mode: input = CODE * 2048 5V GAIN DAQ-12 Users Manual 13 Voltage -5 -2.5 0 2.5 5 10 0000 0000 0000 0000 Unipolar Code n/a n/a 0000 0000 0100 0000 1000 0000 1111 1111 1111 1111 0000 0000 0000 0000 0000 0000 1111 Bipolar Code 1000 0000 1100 0000 0000 0000 0100 0000 0111 1111 n/a 0000 0000 0000 0000 1111 Table 2-2. A/D Conversion Format Examples NOTE: The 'voltage' column is the voltage applied to the A/D converter. This voltage is equivalent to the input voltage multiplied by the amplifier gain. 2.2 Digital to Analog Converters The digital to analog (D/A) section of the DAQ-12 consists of two independent 12-bit multiplying D/A converters, and two independent two-stage output amplifiers. Digital data, (output to the D/A converter by the CPU), is converted to an analog voltage by the D/A converter, amplified by the output amplifiers and becomes output to the 62 pin connector at CN1. The D/A converters used on the DAQ-12 are 12-bit resolution converters. Of the 16 bits written to the D/A, only the 12 least significant bits (D0 - D11) are used for the conversion. The 4 most significant bits (D12 - D15) are ignored. The DAQ-12 implements multiplying D/A converters which makes the analog output proportional to a reference voltage applied to the D/A. Under normal circumstances, the reference voltage should be applied from the internal +5V reference source. An external reference voltage may also be supplied to the D/A. This input from the D-62 connector should not exceed 5 volts and has a typical input impedance of 7.5Kohms. The D/A reference voltage source is selected using jumper J4 as illustrated in Figure 2-4. D/A channel 0 reference Internal Source External Source 4 5 6 1 2 3 J4 Internal Source External Source D/A channel 1 reference Figure 2-4. Jumper J4 Configuration DAQ-12 Users Manual 14 The D/A converter channels may also be operated in unipolar mode: 0 to +5 volts, or bipolar mode: -5 to +5 volts. The output mode is selected using jumper J5 as shown in Figure 2-5. In addition, a gain selection jumper is provided to select an output gain of 1 or 2. When using an external voltage reference, this gain can be used to amplify the D/A output for small reference voltages. WARNING: When the internal voltage reference is used,the D/A gain MUST be set to the gain = 1 position. J5 5 6 7 8 1 2 3 4 Channel 0 select Channel 1 gain Channel 0 gain Channel 1 select Figure 2-5. Jumper J5 Configuration Table 2-3 lists configuration options for jumper J5. Bipolar Unipolar Gain = 1 Gain = 2 Channel 0 connect 1-5 open 1-5 connect 2-6 open 2-6 Channel 1 connect 3-7 open 3-7 connect 4-8 open 4-8 Table 2-3. D/A Converter Mode Selection Options When configured for unipolar operation, the output voltage can be calculated from the equation: A out = V ref * CODE * gain 4096 For bipolar operation, the equation becomes: A out = CODE - 1 * V ref * gain 2048 DAQ-12 Users Manual 15 2.3 Digital Input/Output The DAQ-12 offers four bits of digital output and four bits of digital input for control/monitoring of external digital devices. The four digital output lines are LS TTL compatible and will initialize low (0 volts) on power-up. The four digital inputs are also LS TTL compatible. There is no termination provided on the digital input lines and a read of an unused digital input will result in an indeterminate value. 2.4 Base Address The DAQ-12 uses 16 consecutive I/O address locations in the range 0 to 0FFFFH. Two six-position switches (SW1 and SW2) are used to select the base address. SW1 controls address lines A15 - A10, and SW2 controls A9 - A4. Address lines A3 - A0 are used internally by the DAQ-12 to select which register to access. When selecting a base address for the DAQ-12, an address selection switch in the "OFF" position corresponds to an address bit of "1" while a switch in the "ON" position corresponds to an address bit of "0". The base address of the DAQ-12 must be set on a 16 byte boundary, meaning A3 - A0 are "0". The address of the DAQ-12 as shipped from the factory is 0300H. This setting and other examples are shown in the Figure 2-5. x x x x x x O N x x x x x x SW1 1 2 3 4 5 6 O N 1 2 3 4 5 6 Bit=0 Bit=1 SW2 A A A A A A 15 14 13 12 11 10 0 0 0 0 0 0 0 O N A A A A A A 9 8 7 6 5 4 3 1 2 3 4 5 6 Example1: 0 1 1 0 0 0 0 O N A 1 2 3 4 5 6 D 0 1 1 0 1 0 1 2 3 4 5 6 Example 2: 0 Base I/O Address = 0300H 6 O N 0000 0 1 0 1 1 0 1 O N 1 2 3 4 5 6 xxxx Hex 0000 : 0 0001 : 1 0010 : 2 0011 : 3 0100 : 4 0101 : 5 0110 : 6 0111 : 7 1000 : 8 1001 : 9 1010 : A 1011 : B 1100 : C 1101 : D 1110 : E 1111 : F Base I/O Address = 6AD0H Figure 2-5. I/O Base Address Selection DAQ-12 Users Manual 16 2.5 Clock Selection The DAQ-12 is equipped with a programmable clock circuit to produce data sampling rates independent from the clock rate of the host computer. An onboard 8254 programmable interval timer, with a 10 MHz clock input and either two or three cascaded 16-bit timers, provides the sampling rate. This enables the sampling rate to be adjusted from 5 us between samples to almost a year between samples, in as small as 100ns increments. The DAQ-12's sampling rate can also be generated from an external clock input. This external clock can be connected directly to the A/D converter or through a 16-bit pre-divider, the multi-function timer. Samples are taken on the low to high transition of the clock. WARNING: For the DAQ-12, the maximum data sampling rate is 5us. This restricts clock frequency to a maximum of 200 KHz. Sampling rates in excess of 200 KHz may result in erratic operation and unpredictable results. The clock source, internal or external clock, is software selectable through the DAQ-12's control word register. The configuration of the clock source itself is controlled by jumper block J3 as shown in Figure 2-6, (* indicates factory default). Internal Timer: 2 timers cascaded connect 1-2, 4-8, 6-7* J3 5 1 6 2 7 3 8 4 3 timers cascaded connect 1-5, 2-6, 7-8 External Timer: w/o pre-divider connect 1-2, 3-7, 4-8 with pre-divider connect 1-5, 2-3, 7-8 Figure 2-6. Jumper J3 Configuration DAQ-12 Users Manual 17 2.5.1 Internal Clock Sampling rates for the internal clock can be calculated using the following equation: t = 100ns * [N1*N2] or f = 10MHz / [N1*N2] where N1 is the low 16-bits of the clock divider and N2 is the high 16-bits of the clock divider. The following criteria must be met when selecting values for N1 and N2: 2 < N1 < 65,535 2 < N2 < 65,535 N1 * N2 > 50 Using the equations above, the minimum and maximum data sampling rates for the internal clock can be calculated. Maximum sampling rate: Minimum Sampling Rate: N1 = 2, N2 = 25 N1 = 65535, N2 = 65535 t = 100 x 10 −9 * [(2)*(25)] t = 100 x 10 −9 * 50 t = 5 us t = 100 x 10 −9 * [(65535)*(65535)] t = 100 x 10 −9 * [4.295 x 10 9 ] t = 429.5 sec f = 10 x 10 6 / [(2)*(25)] f = 10 x 10 6 / 50 f = 200 Khz f = 10 x 10 6 / [(65535)*(65535)] f = 10 x 10 6 / [4.295 x 10 9 ] f = 2.328 mHz If extremely slow data sampling rates are needed, the third 8254 timer, the multi-function timer, can be cascaded with the other two to produce a 48-bit clock divider. The sampling rates are then calculated as follows: t = 100ns * [N1*N2*N3] or f = 10MHz / [N1*N2*N3] where N1 is the low 16-bits of the clock divider, N2 is the intermediate 16-bits of the clock divider, and N3 is the high 16-bits of the divider. The following criteria must be met when selecting values for N1, N2, and N3: 2 < N1 < 65,535 2 < N2 < 65,535 2 < N3 < 65,535 N1 * N2 * N3 > 50 DAQ-12 Users Manual 18 When configured for a 48-bit divider, the first sampling period will be slightly longer than the others because the first clock period is required to load the initial value of the multi-function timer. The following equation calculates the additional time of the first period: t add = 100ns * [N1 * N2] To minimize the amount of additional time required for the first sample, select clock dividers such that N1 and N2 are as small as possible and N3 is as large as possible. Using the equations above, the minimum and maximum data sampling rates and the amount of additional time required for the first sample can be calculated. Maximum sampling rate: Minimum sampling rate: N1 = 2, N2 = 5, N3 = 5 N1 = 65535, N2 = 65535, N3 = 65535 t = 100 x 10 −9 * [(2)*(5)*(5)] t = 100 x 10 −9 * 50 t = 5 us t = 100 x 10 −9 * [(65535)*(65535)*(65535)] t = 100 x 10 −9 * [2.815 x 10 14 ] t = 28.146 x 10 6 sec t = 325 days, 18 hours, 23 minutes, 29 sec f = 10 x 10 6 / [(2)*(5)*(5)] f = 10 x 10 6 / 50 f = 200 Khz t add = 100 x 10 −9 * [2 * 5] t add = 100 x 10 −9 * 10 t add = 1 us f = 10 x 10 6 / [(65535)*(65535)*(65535 )] f = 10 x 10 6 / [2.815 x 10 14 ] f = 35.529 nHz t add = 100 x 10 −9 * [65535 * 65535] t add = 100 x 10 −9 * [4.295 x 10 9 ] t add = 429.5 sec 2.5.2 External Clock The external clock input to the DAQ-12 is a TTL level (0 - 5 volt) signal. This input may be used to control the sampling rate directly, or it may be fed through a pre-divider (the multi-function timer) with the timer output controlling the A/D sampling rate. When used to control the sampling rate directly, the frequency of the external clock input may be varied from DC to 100 KHz as long as the width of the low and high portions of the clock are a minimum of 1 us each. The A/D conversion cycle will begin on each rising edge of the external clock input. (See Figure 2-7). 1 usec min 1 usec min 5 usec min Figure 2-7. Sampling Rate External Clock Pulses DAQ-12 Users Manual 19 When the multi-function timer is used as a pre-divider, the frequency of the external clock input may be varied from DC to 10 MHz as long as the high portion of the clock is at least 30ns and the low portion is at least 50ns. Except for the first period, the sampling rate of the DAQ-12 will be the external clock frequency divided by the count value written to the multi-function timer. Since one clock pulse is required to load the initial count value into the timer, the first sampling interval will be one clock cycle longer than the rest. The valid range of count values for the multi-function timer is 2 < count < 65,535 but the resulting sampling rate must be less than 200KHz to assure proper operation of the A/D converter circuitry. (See Figure 2-8). 30 nsec min 50 nsec min 100 nsec min Figure 2-8. Pre-Divider External Clock Pulses 2.6 Trigger Selection The DAQ-12 is capable of accepting an internal software trigger or an external hardware trigger. The trigger selection and trigger level bits in the DAQ-12 control word register select the trigger source and level. Upon reset, the trigger selection and trigger level bits default to the internal software trigger. When the internal trigger is used, an output to the start-of-conversion register will trigger the DAQ-12 to begin sampling the input. For triggering off an external event, the DAQ-12 accepts a level sensitive, TTL compatible trigger input from the D-62 connector. The trigger level bit in the DAQ-12 control word register determines which TTL level is used to trigger the A/D converter to begin sampling. When an internal clock source is used, a delay of not more than 225ns will occur between the trigger and the first data sample. When an external clock is used, the delay will be dependent on the frequency and duty cycle of the clock input. If these delays are unacceptable, the clock and trigger circuitry can be bypassed and a start of conversion pulse can be input directly into the A/D circuitry with a maximum delay of 25ns. If the user controls the start of conversion pulse directly, the sample will be taken on the low to high transition of the pulse, the pulse must have a duration of at least 5 us, and the duty cycle must be between 5 and 80 percent. Jumper J2, shown in Figure 2-9, configures start of conversion control. Start of Conversion: (* indicates factory default) J2 1 2 3 DAQ-12 controlled: connect 1-2* User controlled: connect 2-3 Figure 2-9. Jumper J2 Configuration DAQ-12 Users Manual 20 2.7 Direct Memory Access Direct Memory Access (DMA) transfers provide a way of transferring data from the DAQ-12's A/D converter into the personal computer's memory without using the Central Processing Unit (CPU). DMA capability enables other system software to be executed while data is being input from the DAQ-12. The DAQ-12 actually implements two DMA channels. The advantage of having two DMA channels is that one channel can be transferring data while the second channel is being programmed. When the first channel is finished, the second channel will automatically take over and continue the data transfer. The first channel can then be re-programmed while the second channel is transferring data. In this way, the DAQ-12 can acquire data continuously until terminated by the user. The DAQ-12 supports 16-bit DMA transfers on channels 5, 6, and 7. The DMA channel(s) are selected by jumpers J8 and J9 as shown in Figure 2-10. DMA Channel 1 DMA Channel 2 J9 J8 DRQ7 DACK7 DRQ6 DACK6 DRQ5 DACK5 DRQ7 DACK7 DRQ6 DACK6 DRQ5 DACK5 Figure 2-10. Jumpers J8 and J9 Configuration WARNING: To properly implement the DMA capability, the DRQ and DACK of each DMA channel must be jumpered to the same number, i.e. DRQ 5/DACK 5. If both DMA channels are to be used, each channel must be jumpered to a different number, i.e. channel 1 is jumpered to DRQ 5 /DACK 5 and channel 2 is jumpered to DRQ 7/DACK 7. DAQ-12 Users Manual 21 2.8 Interrupts The DAQ-12 is capable of generating an interrupt from one of four sources: 1. End of conversion signal 2. DMA terminal count 3. Multi-function timer output 4. External interrupt input The interrupt source is software selected through the DAQ-12 control word register. The interrupt level is selected using the jumpers J10 and J11 as shown in Figure 2-11. J11 IRQ 7 IRQ 6 IRQ 5 IRQ 4 IRQ 3 IRQ 2 IRQ 10 IRQ 11 IRQ 12 IRQ 15 IRQ 14 J10 Factory default = IRQ 5 Figure 2-11. Jumpers J10 and J11 Configuration 2.8.1 External Interrupt The external interrupt is a TTL compatible input from the D-62 connector. An interrupt request is generated on a high to low transition of this input. DAQ-12 Users Manual 22 3. External Connections The DAQ-12 is equipped with a high density 62-pin connector as shown in Figure 3-1. 22 2 - CH1+ 4 - CH2(CH10+) 6 - CH4+ 8 - CH5(CH13+) 10 - CH7+ 12 - AOUT0 14 - DOUT0 6 - DOUT3 18 - EXT TRIG 20 - DIN1 22 - CH0+ 24 - CH1(CH9+) 26 - CH3+ 28 - CH4(CH12+) 30 - CH6+ 32 - CH7(CH15+) 34 - AOUT1 36 - DOUT1 38 - EXT INT 40 - DIN3 42 - DIN0 43 - CH0(CH8+) 45 - CH2+ 47 - CH3(CH11+) 49 - CH5+ 51 - CH6(CH14+) 53 - VREF0 55 - VREF1 57 - DOUT2 59 - EXT CLK 61 - DIN2 1 2 3 4 5 6 7 8 9 10 11 12 13 23 24 25 26 44 45 46 47 27 28 48 49 29 50 30 31 32 33 34 35 14 36 15 43 37 16 38 51 52 53 54 55 56 57 58 59 17 39 60 18 40 19 41 61 62 20 42 21 Figure 3-1. 62 Pin Connector Diagram Analog Ground - 1, 3, 5, 7, 9, 11, 13, 44, 46, 48, 50, 52, 54 Digital Ground - 15, 17, 19, 21, 37, 39, 41, 56, 58, 60, 62 DAQ-12 Users Manual 23 CHx-, CHx+ : Analog inputs to the analog to digital converter. When using differential input mode, eight input channels are available (CH0+ to CH7+). When using single-ended inputs, 16 channels are available (CH0+ to CH15+). The first eight channels are input through the connections marked CH0+ to CH7+ and the second eight channels through CH0to CH7-. AOUT0, AOUT1: Analog outputs from the digital to analog converters. Polarity and maximum amplitude depend on the jumper settings and voltage references. Output resistance of the analog outputs is typically 70 ohms. VREF0, VREF1: External voltage references for the digital to analog converters. Input range is 0 to 5.0 volts with a no-load input resistance of 7.5 Kohms typical. EXT CLK, EXT TRG, EXT INT: External clock, trigger, and interrupt inputs respectively. Inputs are TTL compatible. DOUT0, DOUT1, DOUT2, DOUT3: TTL compatible digital output lines. DIN0, DIN1, DIN2, DIN3: TTL compatible input lines. DAQ-12 Users Manual 24 4. Register Description and Programming The DAQ-12 uses 16 consecutive I/O address locations in the range 0 to FFFFH. The card utilizes these addresses for the registers listed in Table 4-1. (* indicates registers located in 8254 counter). Base + 0, 1 Read/Write 16-bit Control Word Register Base + 2, 3 Write only Read only 16-bit Start Conversion Register 16-bit A/D Data Register Base + 4, 5 Write only 16-bit D/A Channel 0 Register Base + 6, 7 Write only 16-bit D/A Channel 1 Register Base + 8 Read/Write 8-bit Digital Input/Output Register Base 9 Read/Write 8-bit Gain Control Register Base A, B Reserved Base + C * Read/Write 8-bit Clock Rate Register (low) Base + D * Read/Write 8-bit Clock Rate Register (high) Base E * Read/Write 8-bit Multi-function Timer Register Base F * Read/Write 8-bit 8254 Control Word/Status Register Table 4-1. DAQ-12 Address Map 4.1 Register Description 4.1.1 Control Word Register The control word register defines and controls many of the DAQ-12'S data conversion functions. This register is 16-bit read/write. D15 D14 D13 D12 D11 D10 D9 D8 Write Read INT2 INT1 INT0 DMAEN DMACT LEVEL TRIG CLK INT2 INT1 INT0 DMAEN DMACH LEVEL TRIG CLK DAQ-12 Users Manual D7 D6 D5 D4 D3 D2 D1 D0 Write Read RUN 0 0 DMASL CHSL3 CHSL2 CHSL1 CHSL0 RUN EOC VALID DMASL CHSL3 CHSL2 CHSL1 CHSL0 25 INT2, INT1 and INT0 control the DAQ-12 interrupt source. INT2 INT1 INT0 DESCRIPTION 0 1 1 1 1 0 0 0 1 1 0 0 1 0 1 Interrupt disabled Interrupt timer 2 Interrupt on terminal count External interrupt Interrupt on end of conversion DMAEN - enables / disables DMA. When set, logic 1, DMA transfers are enabled. DMACT - enables the multi-channel DMA capability of the DAQ-12. When set, logic 1, a terminal count on the active DMA channel causes DMA transfers to begin on the "stand-by" channel. When cleared, logic 0, DMA transfers halt when the terminal count is reached on the active channel. DMACH - indicates which of the DAQ-12'S DMA channels is currently active to transfer data. Logic 0 indicates DMA channel 0, logic 1 indicates DMA channel 1. DMASL - When using differential input mode, eight input channels are available (CH0+ through CH7+). When using single-ended inputs, 16 channels are available (CH0+ through CH15+). The first eight channels are input through the connections marked CH0+ through CH7+ and the second eight channels through CH0- through CH7-. LEVEL - selects the edge of the external trigger input. When set, logic 1, A/D conversions will begin on the falling edge of the external trigger input. When cleared, logic 0, conversions will begin on the rising edge of the external trigger. IMPORTANT: LEVEL must be logic 0 when internal triggering is used. TRIG - selects between internal and external triggers. When set, logic 1, the external trigger is selected. CLK - selects between internal and external clock sources. When set, logic 1, the external clock source is selected. RUN - when set, logic 1, the A/D converter is placed in the 'run' mode and will begin converting data when a trigger is received. RUN may be cleared at any time by writing a "0" to it. When using DMA transfers, RUN is automatically cleared when a terminal count is received with DMACT set to "0". EOC - when set, indicates an end of conversion has taken place and the data is available in the A/D converter data register. DAQ-12 Users Manual 26 VALID - when set, logic 1, indicates at least one data sample was lost because it was read by the personal computer before the next sample was converted. Data was lost because the sampling rate was too fast for the computer to acquire the data. VALID is reset by writing to the start conversion register. CHSL2, CHSL1, CHSL0 - select the multiplexer channel for the analog input signal. (* denotes only available in single ended input mode). CHSL3 CHSL2 CHSL1 CHSL0 MUX channel 0 0 0 0 0 0 0 0 1 1 1 1 1 1 1 1 0 0 0 0 1 1 1 1 0 0 0 0 1 1 1 1 0 0 1 1 0 0 1 1 0 0 1 1 0 0 1 1 0 1 0 1 0 1 0 1 0 1 0 1 0 1 0 1 channel 0 channel 1 channel 2 channel 3 channel 4 channel 5 channel 6 channel 7 channel 8* channel 9* channel 10* channel 11* channel 12* channel 13* channel 14* channel 15* 4.1.2 Start of Conversion Register The start of conversion register is 16-bit write only and performs two functions: 1. When configured for internal triggering, writing a "0" to this register generates the software trigger, starting the data conversion process. 2. Writing a "0" to this register at any time resets the VALID bit in the control word register. This allows the VALID bit to be reset at any time during the conversion process or before the event of an external trigger. 4.1.3 A/D Converter Data Register An input to this register returns the last digital value converted by the A/D converter. This register is 16-bit read only. DAQ-12 Users Manual 27 4.1.4 D/A Converter 0 Register An output to this register causes the lower twelve bits of data to be converted to an analog output on D/A converter channel 0. The four most significant bits of data are ignored. This register is 16-bit write only. 4.1.5 D/A Converter 1 Register An output to this register causes the lower twelve bits of data to be converted to an analog output on D/A converter channel 1. The four most significant bits of data are ignored. This register is 16-bit write only. The remaining four registers are contained in an 8254 counter/timer. 4.1.6 Clock Rate Register (low word) The low word of the clock divider is contained in counter 0 of an 8254 counter/timer. The output of this counter is cascaded into the input of counter 1 to produce a 32-bit timer. Mode 2 must be selected for counter 0 with a minimum count of 2. This register is 8-bit read/write. 4.1.7 Clock Rate Register (high word) The high word of the clock divider is contained in counter 1 of the 8254 counter/timer. Mode 2 must be selected for counter 1 with a minimum count of 2. This register is 8-bit read/write. 4.1.8 Multi-Function Timer Register The multi-function timer is implemented using counter 2 of the 8254 counter/timer. Mode 2 must be selected for this timer with a minimum count of 2. This register is 8-bit read/write. 4.1.9 8254 Control Word/Status Register This register is used to program the mode and report the status of the 8254 counter/timer. This register is 8-bit read/write. DAQ-12 Users Manual 28 4.2 Programming the 8254 Counter/Timer This section provides programming information for the 8254 counter/timer as implemented on the DAQ-12. For more details on the 8254, consult the Intel Micro-processor and Peripheral Handbook. To program any of the counters contained in the 8254 counter/timer, three steps are required: 1. Write the configuration byte to the 8254 mode select/status register. This byte sets the operating mode of the selected counter. 2. Write the least significant byte of the count value to the selected counter register. 3. Write the most significant byte of the count value to the selected counter register. The following examples illustrate the programming sequence for each of the counters in the 8254. The variable 'base_address' is the base address of the DAQ-12 as defined by the address selection switches. Counter 0 - Clock rate register (low word) operating mode: minimum count value: configuration byte: Example: 2 2 0 / 0 / 1 / 1 / 0 / 1 / 0 / 0 = 34H Program the value 2675H into the low word of the clock rate register. output 34H to base_address + 0FH output 75H to base_address + 0CH output 26H to base_address + 0CH Example: Program the value 0008H into the low word of the clock rate register. output 34H to base_address + 0FH output 08H to base_address + 0CH output 00H to base_address + 0CH DAQ-12 Users Manual 29 Counter 1 - Clock rate register (high word) operating mode: minimum count value: configuration byte: Example: 2 2 0 / 1 / 1 / 1 / 0 / 1 / 0 / 0 = 74H Program the value 13A4H into the high word of the clock rate register. output 74H to base_address + 0FH output A4H to base_address + 0DH output 13H to base_address + 0DH Example: Program the value FFFFH into the high word of the clock rate register. output 74H to base_address + 0FH output FFH to base_address + 0DH output FFH to base_address + 0DH Counter 2 - Multi-function timer register operating mode: minimum count value: configuration byte: Example: 2 2 1 / 0 / 1 / 1 / 0 / 1 / 0 / 0 = B4H Program the value 000AH into the multi-function timer register. output B4H to base_address + 0FH output 0AH to base_address + 0EH output 00H to base_address + 0EH Example: Program the value 0100H into the multi-function timer register. output B4H to base_address + 0FH output 00H to base_address + 0EH output 01H to base_address + 0EH DAQ-12 Users Manual 30 DAQ-12 Users Manual Version 2.20 January 28, 1999 Part No. 940-0030-220
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.4 Linearized : No Create Date : 1999:03:02 16:15:57Z Creator : PSCRIPT.DRV Version 4.0 Modify Date : 2005:03:10 13:35:04-06:00 Page Count : 31 Creation Date : 1999:03:02 16:15:57Z Producer : Acrobat Distiller 3.01 for Windows Mod Date : 2005:03:10 13:35:04-06:00 Author : Omega Engineering Metadata Date : 2005:03:10 13:35:04-06:00 Title : Word Pro - daq-12.lwpEXIF Metadata provided by EXIF.tools