Omron RFID Business Development Department V720SHMU01 RFID Transmitter User Manual
Omron Corporation, RFID Business Development Department RFID Transmitter
user manual
PRELIMINARY Electromagnetic Inductive RFID System V720-series User’s Manual USB Type RFID Unit V720S-HMU01 OMRON Corporation Manual Number SRFM-017 About this Manual: This manual describes the installation and operation of the V720-series Electromagnetic Inductive RFID System (V720S-HMU01) and includes the sections described below. Please read this manual carefully and be sure you understand the information provided before attempting to install and operate the System. Section 1 provides the features of the V720S-HMU01. Section 2 provides the specifications and performance characteristics of the V720S-HMU01. Section 3 provides the functions and operations of the V720S-HMU01. Section 4 provides the communications functions and provides details on communications–related data and commands. Section 5 provides the information of characteristics data. Section 6 provides user application software samples. * Prior to connect the RFID unit to the computer via USB, install the specified device driver into the computer referring to the Section 6 of this manual. Precautions Read and Understand this Manual Please read and understand this manual before using the products. Please consult your OMRON representative if you have any questions or comments. Warranty, Limitations of Liability < WARRANTY > OMRON's exclusive warranty is that the products are free from defects in materials and workmanship for a period of one year (or other period if specified) from date of sale by OMRON. OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, REGARDING NON-INFRINGEMENT, MERCHANTABILITY, OR FITNESS FOR PARTICULAR PURPOSE OF THE PRODUCTS. ANY BUYER OR USER ACKNOWLEDGES THAT THE BUYER OR USER ALONE HAS DETERMINED THAT THE PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE. OMRON DISCLAIMS ALL OTHER WARRANTIES, EXPRESS OR IMPLIED. < LIMITATIONS OF LIABILITY > OMRON SHALL NOT BE RESPONSIBLE FOR SPECIAL, INDIRECT, OR CONSEQUENTIAL DAMAGES, LOSS OF PROFITS OR COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED ON CONTRACT, WARRANTY, NEGLIGENCE, OR STRICT LIABILITY. In no event shall the responsibility of OMRON for any act exceed the individual price of the product on which liability is asserted. IN NO EVENT SHALL OMRON BE RESPONSIBLE FOR WARRANTY, REPAIR, OR OTHER CLAIMS REGARDING THE PRODUCTS UNLESS OMRON'S ANALYSIS CONFIRMS THAT THE PRODUCTS WERE PROPERLY HANDLED, STORED, INSTALLED, AND MAINTAINED AND NOT SUBJECT TO CONTAMINATION, ABUSE, MISUSE, OR INAPPROPRIATE MODIFICATION OR REPAIR. ii Application Considerations < SUITABILITY FOR USE > OMRON shall not be responsible for conformity with any standards, codes, or regulations that apply to the combination of the products in the customer's application or use of the products. At the customer's request, OMRON will provide applicable third party certification documents identifying ratings and limitations of use that apply to the products. This information by itself is not sufficient for a complete determination of the suitability of the products in combination with the end product, machine, system, or other application or use. The following are some examples of applications for which particular attention must be given. This is not intended to be an exhaustive list of all possible uses of the products, nor is it intended to imply that the uses listed may be suitable for the products: z Outdoor use, uses involving potential chemical contamination or electrical interference, or conditions or uses not described in this manual. z Nuclear energy control systems, combustion systems, railroad systems, aviation systems, medical equipment, amusement machines, vehicles, safety equipment, and installations subject to separate industry or government regulations. z Systems, machines, and equipment that could present a risk to life or property. Please know and observe all prohibitions of use applicable to the products. NEVER USE THE PRODUCTS FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY WITHOUT ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT THE OMRON PRODUCTS ARE PROPERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM. < PROGRAMMABLE PRODUCTS > OMRON shall not be responsible for the user's programming of a programmable product, or any consequence thereof. Disclaimers < PERFORMANCE DATA > Performance suitability conditions, performance data given in this manual is provided as a guide for the user in determining and does not constitute a warranty. It may represent the result of OMRON’s test and the users must correlate it to actual application requirements. Actual is subject to the OMRON Warranty and Limitations of Liability. iii < CHANGE IN SPECIFICATIONS > Product specifications and accessories may be changed at any time based on improvements and other reasons. It is our practice to change model numbers when published ratings or features are changed, or when significant construction changes are made. However, some specifications of the products may be changed without any notice. When in doubt, special model numbers may be assigned to fix or establish key specifications for your application on your request. Please consult with your OMRON representative at any time to confirm actual specifications of purchased products. < DIMENSIONS AND WEIGHTS > Dimensions and weights are nominal and are not to be used for manufacturing purposes, even when tolerances are shown. < ERRORS AND OMISSIONS > The information in this manual has been carefully checked and is believed to be accurate; however, no responsibility is assumed for clerical, typographical, or proofreading errors, or omissions. iv Safety Precautions This chapter provides important information for the safe use of this product. Ensure to read the information carefully before use. In the safety precautions below, severity is categorized as either “WARNING” or “CAUTION”. WARNING Caution Indicates a potentially hazardous situation which, if not avoided, could result in death or serious injury. Indicates a potentially hazardous situation which, if not avoided, may result in minor or moderate injury, or property damage. Property damage refers to extended damage caused to house/household goods or livestock/pets. ●Description of Symbols Prohibition Indicates an action or activity not permitted. Observe strictly Indicates the need to ensure the safe use of the product. Ensure to establish a solid grounding A label indicating that a device with a grounding terminal should always be grounded. Electric shock hazard A notification that alerts the possibility of electric shock under certain conditions. Do not disassemble A notification that prohibits disassembly when injuries caused by electric shocks may result. Please ensure that all cautions and prohibitions are adhered to, since non-compliance may lead to serious injury or damage, in certain circumstances. WARNING Never disassemble, repair, or modify the main unit and cables. Do not disassemble, repair, or modify this product. Doing so may result in electric shock, fire, or personal injury. Caution Do not drop the device or apply physical shock. Doing so may result in personal injury or device damage. Do not apply strong force to, or place heavy items on the device or cables. Doing so may deform or damage the device, resulting in electric shock or fire. Use and store the product in an environment that is specified in the catalog or operation manual. Failure to do so may cause failure of the device, electric shock, or fire. Do not use or store the device in the following locations: ・ Locations that do not satisfy the specified operating conditions (-10°C to +40°C, 25%RH to 85%RH,non-condensing). ・ Locations that do not satisfy the specified storage conditions (-25°C to +65°C, 25%RH to 85%RH,non-condensing). ・ Locations where the RFID Unit is exposed to direct sunlight. ・ Locations where the RFID Unit is exposed to dust, corrosive gas, saline, or flammable gas. ・ Locations where the RFID Unit is exposed to direct heat. ・ Locations subject to condensation due to high humidity. ・ Locations subject to vibration or impact that exceed the limits outlined in the specifications. ・ Locations where the device may be exposed to water, oil, or chemical agents. (This applies to the models other than waterproof types.) ・ Outdoor vi Store and carry the product in packed state. To avoid interferences with other systems, adhere to the following items and check them before using the product. The product uses a publicly available ISM frequency band of 13.56 MHz to communicate with Tags. Some transceivers, motors, monitoring devices, power supplies (power supply ICs), and other similar RFID systems may generate noise, which cause radio interference and may affect communication with Tags. If the product is required in the vicinity of these items, check for any interference prior to use. On the contrary, the system itself may affect radio station transmissions or medical devices. Be cautious when using the system in the environments where such effects might occur. To minimize noise effects, adhere to the following: ・ Establish a Class D grounding (former Class 3 grounding) for metal objects placed in the vicinity of the system. ・ Keep cables away from those with high voltages or heavy currents. Do not allow the device or cables to be soused or exposed to water. Doing so may result in electric shock, fire or failure of non-waterproof devices or cables. Connect the enclosed USB cable to the product for power supply. Failure to do so may damage the device or generate noise that affects receiving apparatus such as TV or radio. Connect the enclosed USB cable only between this product and a computer. Do not extend or modify the connection with other USB cable or USB adaptor. Handle the USB cable by the connector portion to prevent excessive stress on the connector. Failure to do so may result in poor contact or damage the device. Handle the USB cable by the connector portion to prevent excessive stress on the connector. Failure to do so may result in poor contact or damage the device. If the device fails or is exposed to water (non-waterproof devices or parts), or an unusual smell, smoke, or sparks are detected, immediately refrain from using the device and contact OMRON or a sales representative for service and repair. Continued use of the failed device may result in electric shock or fire. Adhere following instruction to prevent the power supply or AC adaptor belonged to the computer from affecting communication with tags. Keep the distances from the power supply or AC adaptor for the computer as described in 5-6 “Positional Relation Between Reader and Computer” when use the device. This product is not suitable for simultaneous connection of multiple units. Two or more products can not operate connecting with one computer. vii Precautions This chapter provides important information for international standards and copyright. Ensure to read the information carefully before use. Declarations V720S-HMU01 conform to the following laws and standards. 1) US standards FCC Part 15 Subpart C: 2006 FCC ID: OZGV720SHMU01 This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. FCC WARNING: Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment. NOTICE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: -Reorient or relocate the receiving antenna -Increase the separation between the equipment and receiver. -Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. -Consult the dealer or an experienced radio/TV technician for help. 2) Canadian standards RSS-Gen Issue 1: September 2005 RSS-210 Issue 6: September 2005 IC Number: 850L-72HMU01 This device complies with RSS-Gen of IC Rules. Operation is subject to the following two conditions: (1) this device may not cause interference, and (2) this device must accept any interference, including interference that may cause undesired operation of this device. ©Copyright OMRON Corporation 2007. All rights reserved. This document is protected by copyright and is intended solely for use in conjunction with the product. Notify your OMRON representative before copying or reproducing this document in any manner, for any other purpose viii TABLE OF CONTENTS SECTION 1 Product Outline.......................................................................... 1-1 1-1 Features ........................................................................................................................ 1-2 SECTION 2 Specifications and Performance ............................................... 2-1 2-1 Nomenclature and Descriptions ................................................................................. 2-2 2-2 Specifications................................................................................................................ 2-4 2-2-1 General Specifications................................................................................................. 2-4 2-2-2 Interface Specifications ............................................................................................... 2-4 2-3 Dimensions ................................................................................................................... 2-5 SECTION 3 RIFD Unit Operations ............................................................... 3-1 3-1 Outline of Operations.................................................................................................. 3-2 3-2 Tag Access Functions................................................................................................... 3-3 3-2-1 Tag Memory Map ........................................................................................................ 3-3 3-2-2 Single Access and FIFO Access Functions................................................................. 3-8 3-2-3 Lock Function .............................................................................................................. 3-9 SECTION 4 Controlling the RFID Unit ........................................................ 4-1 4-1 Communications Frames ............................................................................................ 4-2 4-1-1 CR Control ................................................................................................................... 4-2 4-2 Data Formats ............................................................................................................... 4-3 4-2-1 Command Code List.................................................................................................... 4-3 4-2-2 Communications Options ........................................................................................... 4-5 4-2-3 End Code List .............................................................................................................. 4-9 4-3 Commands and Responses during CR Control ........................................................ 4-10 4-3-1 General Commands (Commands sent to RFID Unit) .............................................. 4-10 4-3-2 Commands Common to the I-CODE1 and the I-CODESLI Chips ........................ 4-11 4-3-3 Commands Specific to the I-CODESLI Chip ........................................................... 4-15 4-3-4 Commands Specific to the I-CODE1 Chip................................................................ 4-18 4-3-5 Old Commands Specific to the I-CODE1 Chip ........................................................ 4-20 SECTION 5 Characteristics Data (Reference).............................................. 5-1 5-1 Communications Distance (Reference)...................................................................... 5-2 5-2 Diagram of Communications Range (Reference) ..................................................... 5-3 5-3 Communications Time (Reference)............................................................................ 5-6 5-3-1 Communications time ................................................................................................. 5-6 5-3-2 TAT (Turn Around Time)............................................................................................ 5-8 5-4 Effects of Surrounding Metal (Reference)................................................................. 5-9 5-5 Mutual Interference (Reference)................................................................................ 5-10 5-6 Positional Relation Between the Reader and the Computer (Reference) ............... 5-11 SECTION 6 Driver Installation .................................................................... 6-1 6-1 Before installation........................................................................................................ 6-2 6-2 Driver Installation ....................................................................................................... 6-3 ix SECTION 1 Product Outline The RFID Unit is a unit, which includes an antenna PCB and a control PCB with control and send-receive functions for communicating with OMRON V720-series Tags that use two types of Phillips Semiconductor I-CODE chips (product name: SL1 ICS30 01, commonly known as "I-CODE1", and product name: SL2 ICS20, commonly known as I-CODESLI); it also supports USB interface (USB2.0). The SL2 ICS20 chip fully conforms to ISO/IEC15693. 1-1 Features...................................................................................................................1-2 1-1 1-1 Features 1-1 Section 1-1 Features Computer USB 2.0 (Personal Computer) RFID Unit V720S-HMU01 V720 series Tag V720S-HMU01 Compact Body • 80 x 50 x t19.5mm Baud Rate and Communication Control Method for communicating with the Host Control Unit • The USB interface enables simple connection to the computer. • With the specified device driver, the reader works as a virtual COM port. • The baud rate in use is 9,600 bps (as a virtual COM port). • A normal CR control is used as the communications control method. (Note: the number-of-characters control method is not supported) User-friendly Command Structure • Easy-to-understand command structure. • Built-in repetitive data write command (enabled when writing identical data to tag memory areas). • Specifiable data code (hexadecimal or ASCII) using read/write command. Many Operating Modes • • 1-2 Supports two operating modes -- single access mode and FIFO access mode -- according to the status of the tags within the communications range. Support for four communication modes according to the communication method with the Tag (three types in single access mode; Trigger, Auto, and Repeat). SECTION 2 Specifications and Performance 2-1 Nomenclature and Descriptions ...........................................................................2-2 2-2 Specifications .........................................................................................................2-4 2-2-1 General Specifications...........................................................................................2-4 2-2-2 Interface Specifications .........................................................................................2-4 2-3 Dimensions .............................................................................................................2-5 2-1 2-1 Nomenclature and Descriptions 2-1 Section 2-1 Nomenclature and Descriptions V720S-HMU01 Antenna USB Connector LED Indicator Component Descriptions • USB Connector (USB Connector Mini B type) To connect to the computer, insert USB cable here. The USB interface is conforms to USB 2.0. • Antenna To read tag data, set the tags near the antenna area as shown below. The communication surface (antenna surface) is the top. • LED Indicator When the reader is communicating with the tag, the LED light is on. ! Caution As the antenna is built in at the top of the RFID Unit, the direction of communication with the tag is the upward. 2-2 2-2 Specifications 2-2 Section 2-2 Specifications 2-2-1 General Specifications Item Dimensions 80 × 50 × t 19.5 mm Mounting method Set on a flat surface Power supply voltage Current consumption 5.0 VDC (USB bus power) 100 mA max. Destruction: 10 to 150 Hz, 0.1-mm half amplitude at 15 m/s² in X, Y, and Z directions 10 times each for 8 minutes Destruction: 150 m/s² three times each in 6 directions Vibration resistance Shock resistance Ambient operating temperature Ambient storage temperature Ambient operating humidity Communications frequency Weight V720S-HMU01 -10 to +40℃ -25 to +65℃ 25%RH to 85%RH max. (with no condensation) 13.56 MHz Approx. 40 g Extremely low power radio station (Radio Law Article 4 Section 1 radio stations that discharge extremely low electric waves and specified by the Ministry of Posts and Radio standards Telecommunications ) In accordance with Radio Law enforcement regulation Article 6 Section 1, the field intensity is 500µV/m or less at distance of 3 m (322 MHz or less). *1 For the information of communications distance and area, refer to the data in 5-1 and 5-2 of section 5. 2-2-2 Interface Specifications Item Connectors Communications method Synchronous method Communications control method Baud rate Character format Error detection method Bit send order Details USB mini B Connector 2-wire half duplex serial (appears as a virtual COM port on USB ) Asynchronous mode or start-stop synchronous mode CR control (Number-of-characters control is not supported) 9,600 bps (Full speed device 12Mbps as a USB device) Start bits Data bits Parity Stop bits Even Total bits 11 Parity Least significant bit (LSB) first 2-3 2-3 Dimensions 2-3 Dimensions V720S-HMU01 2-4 Section 2-3 SECTION 3 RFID Unit Operations 3-1 Outline of Operations.............................................................................................3-2 3-2 Tag Access Functions............................................................................................3-3 3-2-1 Tag Memory Map...............................................................................................3-3 3-2-2 Single Access and FIFO Access Functions ......................................................3-8 3-2-3 Lock Function ....................................................................................................3-9 3-1 3-1 Outline of Operations 3-1 Section 3-1 Outline of Operations The RFID Unit reads or writes to the tags using commands sent from the host control unit, and returns the processing responses to the host control unit. Command Control Unit (Computer) RFID Unit V720S-HMU01 V720 series Tag Response The RFID Unit has three operating modes. The conditions for changing the mode are shown in the following diagram. (1) Command waiting mode In this mode, the COM port is open and ready to receive a command as a virtual COM port. (2) Oscillation mode This mode performs communications with the tags. When using FIFO access mode, oscillation mode continues until a STOP command or STOP signal is input. (3) Standby mode In this mode, the COM port is closed as a virtual COM port. Command waiting mode COM Port Close Commands from host received COM Port Open Responses to host sent Standby mode Note Oscillation mode As the first step, open the COM port so that the RFID unit will shift its mode from “Standby mode” to the “Command waiting mode”. 3-2 3-2 Tag Access Functions 3-2 Section 3-2 Tag Access Functions 3-2-1 Memory Map of Tag 3-2-1-1 I-CODE1 Chip (Philips IC product name : SL1 ICS30 01, SL ICS31 01) 1) Memory Map of I-CODE1 These specifications describe a Tag incorporating an IC chip I- CODE1 Label IC from Philips, which is accessed by the system. This chip consists of a 64-byte memory. The upper five blocks (Blocks 0 to 4) of the memory are used as a system area having functions that do not relate to user memory. OMRON offers special commands for accessing this area in order to ensure the great ease of these functions by the user. Refer to Command List for details. OMRON defines the blocks below Block 5 as the user memory area. Block 5 is page 00h, and the subsequent blocks are allocated as shown below. The memory is organized with four bytes as one page (4 bytes = 32 bits). One page is the minimum unit that can be read from and written to the memory. The memory allocation described in this user's manual is in accordance with OMRON's memory allocation scheme. OMRON Bank Page B Hex C Hex D Hex E Hex F Hex 0 Hex 1 Hex 00 Hex 2 Hex 3 Hex 4 Hex 5 Hex 6 Hex 7 Hex 8 Hex 9 Hex A Hex Byte 0 Byte 1 Byte 2 SNR SNR Write-protect QUIET/EAS Family code/application ID or user area User area Byte 3 PHILIPS Block 10 11 12 13 14 15 Special Note Block 4 can be used as part of the user memory when the Distinguished Tag Read/Write function by family code (FC) or application ID (AI) is not used. If such use is preferred, define this page as F Hex to use it as part of the user memory. In this case, the user memory area becomes 12 pages long. 3-3 3-2 Tag Access Functions Section 3-2 2) System Area of I-CODE1 The system area of I-CODE1 is mapped onto the memory. OMRON allocates the system area to pages B Hex to F Hex. (1) SNR(pages C Hex, B Hex) SNR is a tag-specific code and has been written into the memory during the chip production process. The RFID Unit is shipped with this page write-access inhibited (refer to page D Hex); there is no way of making this page rewritable by the user. (2) Write-access conditions (page D Hex) The pages are write-inhibited permanently if they are so indicated in the memory map. The factory settings are as follow. If the two bits of a particular page are 0.0, that page is write-protected. Page D Hex Byte 0 Byte 1 Byte 2 Byte 3 MSB LSB Page E Hex Page 2 Hex Page 6 Hex Page A Hex Page D Hex Page 1 Hex Page 5 Hex Page 9 Hex Page C Hex Page 0 Hex Page 4 Hex Page 8 Hex Page B Hex Page F Hex Page 3 Hex Page 7 Hex (3) QUIET/EAS (page E Hex) QUIET mode: All the functions of a tag are suspended completely. Use Reset Quiet Bit to resume these functions. (q=0: QUIET mode disabled; q=1: QUIET mode enabled) EAS mode: inhibition/permission of EAS function (e=0: EAS mode disabled; e=1: EAS mode enabled) Page Eh Byte 0 Byte 1 Byte 2 Byte 3 MSB × × × × × × × × × × × × × × × × × × × × × × × × × LSB × × × The pages marked with "×" in the table above are reserved for future use. (4) Family code/application ID (page F Hex) Family code and application ID are special areas for enabling the user to identify an IC that is suitable to a specific user application. Block Eh Byte 0 Byte 1 Byte 2 Byte 3 MSB LSB Family code Application ID User area User area 3-4 3-2 Tag Access Functions Section 3-2 3-2-1-2 I-CODESLI Chip (Philips IC product name : SL2 ICS20) In this module, processing is performed with the minimum access unit of one page (4 bytes), the maximum number of pages that can be processed simultaneously being one bank (16 pages), and up to a total of 16 banks (266 pages) being accessible. The I-CODE 2 user memory area spans 112 bytes, or 28 pages, from page 00 Hex to page 1B Hex. 1) Max. address space of ISO/IEC15693 chip with a 4 Bytes/page organization Bank 00 Hex Page 0 Hex 1 Hex 2 Hex 3 Hex 4 Hex 5 Hex 6 Hex 7 Hex 8 Hex 9 Hex A Hex 15 16 17 B Hex 27 31 Byte 2 Byte 3 Page 00 Hex to 1B Hex (28 pages =112 bytes) ⋮ ⋮ ⋮ ⋮ 0 Hex 1 Hex 240 241 ⋮ ⋮ Byte 1 ⋮ ⋮ F Hex 0 Hex 1 Hex ⋮ ⋮ 0F Hex Byte 0 I-CODESLI user memory area ⋮ 01 Hex Block F Hex 255 Caution The memory map above shows a memory area covered by the product. It complies with the ISO/IEC15693 standard. Proper operation is ensured for our Tag, which incorporates Philips' IC product SL2ICS20 (known as "I-CODESLI"), although this product incorporates a firmware allowing to access chips with a four bytes/page organization and fully compliant to ISO/IEC15693. Perform check test adequately when using other company’s tag or tags that incorporate other ISO/IEC15693 chips. 3-5 3-2 Tag Access Functions Section 3-2 2) System Area of I-CODESLI The I-CODESLI system area of is reserved in an area different from the user memory. Special commands are used for accessing the system area. Byte 0 Byte 1 Byte 2 UID UID EAS/AFI/DSFID Write-protect Byte 3 (1) UID UID is a tag-specific code and has been written into the memory during the chip production process. The RFID Unit is shipped with this page write-access inhibited; there is no way of making this page rewritable by the user. (2) EAS/AFI/DSFID EAS mode: Inhibition/permission of EAS function (e=0: EAS mode disabled; e=1: EAS mode enabled) Byte 1 MSB × × × × × × × LSB The pages marked with "×" in the table above are reserved for future use. (3) AFI AFI is a special area for enabling the user to identify a tag that is suitable to a specific user application. Byte 2 AFI upper 4 bits MSB AFI upper 4 bits AFI lower 4 bits 0,Y 0,Y 0,Y 0,Y 0,Y 0,Y 0,Y 0,Y 0,Y 0,Y 0,Y 0,Y 0,Y 0,Y 0,Y LSB AFI lower 4 bits Application area Example/reference All areas X area Y category of X area Limited to Y category Transportation Finance Recognition Telecommunication Medical care Multimedia Game Data storage Logistics Home delivery services Mail Airplane luggage Reservation Reservation Reservation Area not identified Selected extensively Mass-transit, bus, air plane Bank Access control Public telephone, CSM Internet Portable file *Remarks: X=1 to F Y=1 to F 3-6 3-2 Tag Access Functions Section 3-2 (4) DSFID DSFID indicates how the data is configured in the memory. MSB LSB Byte 3 DSFID (5) Write-access conditions The pages are write-inhibited permanently if they are so indicated in the memory map. The factory settings are as follow. If the bit of a particular page is 1, that page is write-protected. Byte 0 Byte 1 Byte 2 Byte 3 MSB Page 03 Page 02 Page 01 Page 00 LSB Page 0B Page 0A Page 09 Page 08 Page 07 Page 06 Page 05 Page 04 Page 13 Page 12 Page 11 Page 10 Page 0F Page 0E Page 0D Page 0C Page 1B Page 1A Page 19 Page 18 Page 17 Page 16 Page 15 Page 14 3-7 3-2 Tag Access Functions Section 3-2 3-2-2 Single Access and FIFO Access Functions Single Access Mode Use this mode to communicate with only one tag within the RFID Unit communications area. The time required for communications with the tag is shorter compared with FIFO access mode. FIFO Access Mode FIFO (First In First Out) access mode enables reading tags in order as they enter the antenna communications range. Tags with which communications have been completed are prohibited from being accessed again, so even if tags with which communications have been completed are still within range of the antenna, communications will be possible with new tags as they enter the communications range. When two or more tags enter the antenna communications range at the same time, a communications error will occur. When a tag to which access has been prohibited moves out of the communications area, communications with it will be possible again if it reenters the antenna communications range. The above diagram shows an example of a tag inspection line. When the distance between tags is small, two tags may enter the RFID Unit communications range at the same time. If this happens when in Single Access Mode, a communications error will occur, or even if read/write appears to have been performed, there is no way to know which of the two tags was read. In FIFO Access Mode, tags entering communications range can be read or written to in order, so this mode is suited to applications such as a tag inspection line, in which the order of access is important. 3-8 3-2 Tag Access Functions Section 3-2 3-2-3 Lock Function The lock function is a protection function provided to prevent the loss of data by unintentionally overwriting fixed data stored on the tags. This function can be set using the lock command. This function can be set using the lock command. There is a lock setting area in the tag system area, enabling user-defined areas to be write-protected one page at a time. If the write command is executed for a page that has been write-protected, a write processing error will occur. Note The lock function used with the V720 Series cannot be canceled. Pages that have been write-protected cannot be written to again, so be careful when using this function. 3-9 SECTION 4 Controlling the RFID Unit 4-1 Communications Frames .............................................. 4-2 4-1-1 CR Control ........................................................... 4-2 4-2 Data Formats ......................................................... 4-3 4-2-1 Command Code List ................................................... 4-3 4-2-2 Communications Options ............................................... 4-5 4-2-3 End Code List ........................................................ 4-9 4-3 Commands and Responses during CR Control........................... 4-10 4-3-1 General Commands (Commands sent to RFID Unit) ....................... 4-10 4-3-2 Commands Common to the I-CODE1 and the I-CODESLI Chips ............. 4-11 4-3-3 Commands Specific to the I-CODESLI Chip ............................... 4-15 4-3-4 Commands Specific to the I-CODE1 Chip................................. 4-18 4-3-5 Old Commands Specific to the I-CODE1 Chip ............................. 4-20 ! Caution The method for controlling the RFID Unit from the host control unit is the CR control method. CR control Data in the communications frame is handled as ASCII characters in 2-digit hexadecimal code (ASCII code). CR control simplifies operations with the host. In this manual, the codes are displayed as follows: ASCII characters: ’ ×× ‘ Control code using ASCII characters: ‘‘ Displayed as hexadecimal code: ×× Hex 4-1 4-1 Communications Frames 4-1 Section 4-1 Communications Frames 4-1-1 CR control The frame format consists of data in ASCII characters and a terminator. ' ' (ASCII: 0D Hex), the terminator, cannot be used in the data ASCII characters. The CR control method is useful when the RFID Unit is connected to a PC and the like. Data: 138 characters max Data 1 Data Data Terminator Data 2 No. of characters 1 to 138 ⋅⋅⋅⋅⋅⋅ Data n Terminator Details Command parameters (ASCII characters) Code ‘ ‘ (0D Hex), which indicates end of communications frame (Communications Control Procedure) When a character is first received, reception starts, and when is received, the frame ends. If the interval between data is greater than 2 sec, a communications error occurs. If a communications error occurs, a frame error end code (Error code: '18') is sent as the response from the RFID Unit to the host. 4-2 Data Formats 4-2 Section 4-2 Data Formats The data in the communications frames used for commands and responses use the following formats. Command The command data consists of the command, communications options, and parameters. The communications options are added only to commands 01 to 03. Command Communications option ⋅⋅⋅⋅⋅⋅ Parameter 1 Parameter n Response The response data consists of an end code and parameters. End code Parameter 1 ⋅⋅⋅⋅⋅⋅ Parameter n 4-2-1 Command Code List Commands specify RFID Unit processing. The commands are given in the following table. 1) General Commands (Commands sent to the RFID Unit) Command name Test ACK NACK STOP No. 10 11 12 13 Details Sends the received data to the host device. The host device received the data properly. The host device did not receive the data properly. Ends the command currently being executed. Stops antenna oscillation. 2) Commands Common to the I-CODE1 and the I-CODESLI Chips Command name Read Write Write identical data Read UID (SNR) Set write-protection No. 31 32 33 35 39 Details Reads tag memory data on a page basis. Writes data to tag memory on a page basis. Writes identical data to tag memory on a page basis. Reads tag serial numbers. Sets write-protection on a page basis 3) Commands Specific to the I-CODESLI Chip Command name Set AFI Set DSFID Read Tag info Read UID & data EAS Alarm Set EAS No. 36 37 3A 41 42 43 Details Overwrites and locks tag AFI. Overwrites and locks tag DSFID. Reads tag system information. Reads tag UID and memory data simultaneously. Sends EAS Alarm to the tag. Enables/disables and locks EAS. 4) Commands Specific to the I-CODE1 Chip Command name Read SNR Read Family Code and Application ID Set Family Code and Application ID Set EAS EAS No. 05 06 Details Reads tag serial numbers. Reads tag family codes and application IDs. 07 Writes tag family codes and application IDs. 08 24 Permits/prohibits EAS commands to the tags. Sends EAS commands to the tags. 4-3 4-2 Data Formats Section 4-2 5) Old Commands Specific to the I-CODE1 Chip (replaced by the Commands Common to the I-CODE1 and the I-CODESLI Chips) Command name Read Write Write identical data Set write-protection 4-4 No. 01 02 03 09 Details Reads tag memory data on a page basis. Writes data to tag memory on a page basis. Writes identical data to tag memory on a page basis. Sets write-protection on a page basis. 4-2 Data Formats Section 4-2 4-2-2 Communications Options The data code and communications mode can be specified as communications options. Data code specification is possible only when using CR control. Bit Setting details Tag type Data Communications mode code *Bits 6 and 7 must be 0. 1) Specifying Tag Type Setting Value I・CODE1 When accessing a tag equipped with I-CODE1 When accessing a tag equipped with I-CODESLI Addendum: when accessing the tag equipped with a chip with a four bytes/page organization and fully conforming to ISO/IEC15693 ISO/IEC15693 (4byte/page type) Details 2) Specifying Data Code Using CR Control Specify the data code to perform read/write communications between the RFID Unit and the host control unit. The specification concerns the data to be written/read to/from the user memory, as well as the test data. Setting Val ue Hex Details Two-character data consisting of 0 to 9 and A to F is handled as 2-digit hexadecimal data. Two characters occupy one byte of tag memory. Example: When 12345678 is written to page 0, tag memory is used as shown below. Page 0 ASCII Byte 0 Byte 1 Byte 2 Byte 3 12 34 56 78 One character of data occupies one byte of tag memory as ASCII or JIS8 unit code. Example: When ‘ABCD’ is written to page 0, tag memory is used as shown below. Byte 0 Byte 1 Byte 2 Byte 3 41 42 43 44 4-5 4-2 Data Formats Section 4-2 3) Specifying the Communications Mode The following seven communications modes are supported for different processing procedures and execution timing. Communications mode Single Trigger 0 Hex Single Auto 1 Hex Single Repeat 2 Hex FIFO Trigger 8 Hex FIFO Auto FIFO Continuous FIFO Repeat Note 4-6 No. Details After a command is received, communications with the tag is performed immediately and a response is sent. If there is no tag in communications range, a No Tag error is sent. After the response has been sent, the mode changes to sleep mode. Only one tag is permitted in communications range. After a command is received, this mode waits for a tag to enter communications range, and then performs communications with the tag. After the response has been sent, the mode changes to sleep mode. If a STOP command is received while waiting for a tag, the command is ended. Only one tag is permitted in communications range. After a command is received, this mode waits for a tag to enter communications range, and then performs communications with the tag. If this mode has been specified, the command is repeated sequentially until a STOP command is received. This mode is enabled only for read commands. Only one tag is permitted in communications range. After a command is received, communications with the tag is performed immediately and a response is sent. If there is no tag in communications range, a No Tag error is sent. Access is prohibited to tags with which communications have been completed, and the RFID Unit continues unmodulated oscillation. Tags with which communications have been completed do not respond to the next command. After the response has been sent, the mode changes to sleep mode. If a STOP command is received, oscillation stops. 9 Hex After a command is received, this mode waits for a tag to enter communications range, and then performs communications with the tag. Access is prohibited to tags with which communications have been completed, and the RFID Unit continues unmodulated oscillation. Tags with which communications have been completed do not respond to the next command. After the response has been sent, the mode changes to sleep mode. If a STOP command is received while waiting for a tag, the command is ended. A Hex After a command is received, this mode waits for a tag to enter communications range, and then performs communications with the tag. Access is prohibited to tags with which communications have been completed, and the RFID Unit continues unmodulated oscillation. Tags with which communications have been completed do not respond to the next command. After the response has been sent, when ACK is received, this mode again waits for a tag to enter communications range, and then performs communications with the tag. If a STOP command is received while waiting for a tag, the command is ended. B Hex After a command is received, this mode waits for a tag to enter communications range, and then performs communications with the tag. Access is prohibited to tags with which communications have been completed. Tags with which communications have been completed do not respond to the next command. If this mode has been specified, the command is repeated sequentially until a STOP command is received. Single repeat mode can only be specified for commands 01, 31, 35, 3A, 41, and 42. 4-2 Data Formats Section 4-2 4) Communications Modes Diagrams 1) Single Trigger Operation Sequence Host control unit to RIFD Unit command command RIFD Unit to host control unit response1 response2 No Tag Error Communications with tag Command processing Tag operation Command processing tag 1 2) Single Auto Operation Sequence Host control unit to RIFD Unit command command RIFD Unit to host control unit stop response1 response Communications with tag Tag detection Command processing Tag detection End processing tag 1 Tag operation 3) Single Repeat Operation Sequence H ost control unit to RIFD Unit R IFD U nit to host control unit com m and stop resp onse1 respon se2 resp onse3 respon se Tag detection C om m unications with tag Tag operation Tag detection C om m andTag detection C om m and processing processing tag 1 tag 2 C om m and processing Tag detection E nd processing tag 3 4-7 4-2 Data Formats Section 4-2 4) FIFO Trigger Operation Sequence Host control unit to RIFD Unit command command RIFD Unit to host control unit response1 response2 No Tag Error Communications with tag Command processing Tag operation Unmodulated oscillation Command processing Unmodulated oscillation tag 1 5) FIFO Auto Operation Sequence Host control unit to RFID Unit command command stop RFID Unit to host control unit response1 response Communications with tag Tag detection Command processing Unmodulated oscillation End processing Tag detection tag 1 Tag operation 6) FIFO Continuous Operation Sequence Host control unit to RIFD Unit ACK command NACK stop RIFD Unit to host control unit response1 response2 response2 response Communications with tag Tag detection Unmodulated oscillation tag 1 Tag operation Unmodulated oscillation Tag Command detection processing End processing tag 2 7) FIFO Repeat Operation Sequence Host control unit to RIFD Unit stop command RIFD Unit to host control unit response1 response2 Tag Command detection processing 4-8 response Tag detection Communications with tag Tag operation response3 tag 1 Tag detection Command processing tag 2 Command processing tag 3 Tag detection End processing 4-2 Data Formats Section 4-2 4-2-3 End Code List Communications between Host Device and RFID Unit End code Name Details 10 Parity Error • There is a character with a parity error in the command received. 11 Framing Error • There is a character with a framing error in the command received. 12 Overrun Error • There is a character with an overrun error in the command received. 14 Format Error • Command format does not match specifications. Examples: Command is not defined, page/address specifications are invalid, etc. 18 Frame Error • Characters are received more than 2 sec apart • Frame received exceeds 140 Communications between RFID Unit and Tags End code 70 71 72 Name Details • Interference, such as noise, has occurred during communications with Communications Error the tags, preventing normal completion. • Write command has been specified to a page that has been write-prohibited. • There is a tag area to which reading is possible, but writing is not possible. Write Error • Correct data cannot be written because the tag has exceeded its usable write life. • There was no tag in the communications area when the command No Tag Error was executed. • The specified pages do not exist (I-CODESLI). 79 Command Error • (see Comparison with ISO Error Code) 7A Address Error • The specified pages do not exist. Comparison with ISO Error Code When an ISO tag responds by returning an error, the unit responds with the end code shown in the following table. ISO code Details End code 01 Command not in use. Cannot recognize request command code. 79 02 Unrecognized command. Example: format error 79 03 Any unused command. 79 0F Unknown or unused error code. 79 10 Specified block cannot be used (not present). 7A 11 Specified block cannot be re-locked because it has been already locked. 00 12 The contents of the specified block cannot be changed because it is locked. 71 13 Writing to the specified block did not end normally. 71 14 Locking of the specified block did not end normally. 71 RFU 79 Others 4-9 4-3 Commands and Responses during CR Control 4-3 Section 4-3 Commands and Responses during CR Control 4-3-1 General Commands (Commands sent to the RFID Unit) 1) Test This command tests communications with the host. When this command is received, the RFID Unit sends the same data to the host. Command Command ‘1‘ ‘0‘ Test data ⋅⋅⋅⋅⋅⋅ Data 1 Data n Response End code ‘0‘ ‘0‘ Test data Data 1 ⋅⋅⋅⋅⋅⋅ Data n The test data returned is the same as the command data. 2) ACK Use this command when the communications mode is FIFO Continuous Mode. ACK is sent after the response has been received, and the next read operation is permitted. Command Command ‘1‘ ‘1‘ Response There is no response to ACK. 3) NACK If the host control unit does not receive a response normally, NACK is sent as a request to resend the response. When the RFID Unit receives the NACK command, it resends the immediately preceding response. Command Command ‘1‘ ‘2‘ Response The immediately preceding response data is resent. 4) STOP Use this command to stop the RFID Unit processing. When this command is received, the RFID Unit stops processing the current command and enters sleep mode. If the antenna is oscillating, the oscillation also stops. Command Command ‘1‘ ‘3‘ Response End code ‘0‘ ‘0‘ 4-3 Commands and Responses during CR Control 4-3-2 Section 4-3 Commands Common to the I-CODE1 and the I-CODESLI Chips 1) Read Use this command to read data from the tags. Data can be read from a user-specified page. Command This command sends the pages to be read as command parameters. The page specification is as follows: The bits that correspond to the pages to be read are set to 1, and all other bits are set to 0. This binary number is converted to hexadecimal and sent with the command. The pages are specified by the user. Command ‘ 3‘ Communications option Bank specification Page specification ‘1‘ Tag type Bank specification Page specification (settable value) (Settable value) I-CODE1 ‘ 00 ‘ ‘00’ to ‘FF’ ‘00’ to ‘FF’ ISO chip ‘00’ to ‘0F’ ‘00’ to ‘FF’ ‘00’ to ‘FF’ Response Returns the data read and the end code (normal end: ‘00’). The read data is returned sequentially in ascending order of the pages specified. If an error occurs, an error code is returned. In the case of a Tag equipped with I-CODE1, the read data is returned in the order: B⇒C⇒D⇒E⇒F⇒0⇒1⇒···⇒A. Read data*1 End code ‘0‘ *1 ‘0‘ Data 1 ・・・ Data n Number of data n = Number of specified pages x 8 (hexadecimal) Number of data n = Number of specified pages x 4 (ASCII) Command Example The following table gives the tag user memory details for the following example of commands and responses. Page 10 Byte 0 30 Hex 34 Hex 38 Hex 40 Hex 44 Hex 48 Hex 4C Hex 50 Hex 54 Hex 58 Hex 62 Hex Byte 1 31 Hex 35 Hex 39 Hex 41 Hex 45 Hex 49 Hex 4D Hex 51 Hex 55 Hex 59 Hex 63 Hex Byte 2 32 Hex 36 Hex 30 Hex 42 Hex 46 Hex 4A Hex 4E Hex 52 Hex 56 Hex 5A Hex 64 Hex Byte 3 33 Hex 37 Hex 30 Hex 43 Hex 47 Hex 4B Hex 4F Hex 53 Hex 57 Hex 61 Hex 65 Hex (1) Reading the following four pages: 1, 3, 5, and 6, using Single Trigger Mode with hexadecimal is as follows: Command ‘01 00 006A ‘ Response ‘00 34353637 40414243 48494A4B 4C4D4E4F ‘ (2) Reading the following four pages: 1, 3, 5, and 6, using Single Trigger Mode with ASCII is as follows: Command ‘01 10 006A ‘ Response ‘00 4567 @ABC HIJK LMNO ‘ 4-11 4-3 Commands and Responses during CR Control Section 4-3 2) Write Use this command to write tag data on a page basis. Data can be written to user-specified pages (except B Hex to E Hex for I-CODE1). The maximum number of pages which can be written to in a single operation is one bank, and writing to pages across banks is impossible. There is no need to perform the verify read process, since this command performs it as part of its execution. Command This command sends the data to be written as parameters. The page specification is as follows: The bits that correspond to the pages to be written are set to 1, and all other bits are set to 0. This binary number is converted to hexadecimal and sent with the command. Specify the write data sequentially in ascending order of the specified page. In the case of a Tag equipped with I-CODE1, specify the write data in the order: F⇒0⇒1⇒···⇒A. Command ‘ 3‘ Bank specification Page specification Write data*1 ‘2‘ Tag type *1 Communications option … Data 1 Bank specification (Settable value) I-CODE1 ‘ 00 ‘ ISO chip ‘00’ to ‘0F’ Data n Page specification (settable value) ‘00’ to ‘FF’ ‘00’ to ‘FF’ Number of data n = Number of specified pages x 8 (hexadecimal) Number of data n = Number of specified pages x 4 (ASCII) Response The response returns the end code (normal end: ‘00’). End code ‘0‘ ‘0‘ Command Example The following table gives details of tag user memory when executing the following command. Page 10 Byte 0 30 Hex 34 Hex 38 Hex 40 Hex 44 Hex 48 Hex 4C Hex 50 Hex 52 Hex 58 Hex 56 Hex Byte 1 31 Hex 35 Hex 39 Hex 41 Hex 45 Hex 49 Hex 4D Hex 51 Hex 46 Hex 59 Hex 37 Hex Byte 2 32 Hex 36 Hex 30 Hex 42 Hex 46 Hex 4A Hex 4E Hex 52 Hex 49 Hex 5A Hex 32 Hex Byte 3 33 Hex 37 Hex 30 Hex 43 Hex 47 Hex 4B Hex 4F Hex 53 Hex 44 Hex 61 Hex 30 Hex (1) Writing 52464944 hexadecimal to page 8, and 56373230 hexadecimal to page 10 using FIFO Repeat Mode, with hexadecimal: Command ‘02 0B 0500 52464944 56373230 ‘ Response ‘00 (2) Writing ‘RFID’ hexadecimal to page 8, and ‘V720’ hexadecimal to page 10 using FIFO Repeat Mode, with ASCII: Command ‘02 1B 0500 RFID V720 ‘ Response ‘00 ‘ Data written to tag memory is the same for both (1) and (2). 4-12 4-3 Commands and Responses during CR Control Section 4-3 3) Write identical data Use this command to write identical data to tags by the page. Data can be written to user-specified pages (except B Hex to E Hex for I-CODE1). This command is useful when writing the same data to multiple pages. The maximum number of pages which can be written to in a single operation is one bank, and writing to pages across banks is impossible. There is no need to perform the verify read process, since this command performs it as part of its execution. Command As parameters, the command sends specification of the pages to be written and the data to write to the specified pages one page at a time. The page specification is as follows: The bits that correspond to the pages to be written are set to 1, and all other bits are set to 0. This binary number is converted to hexadecimal and sent with the command. The write data is specified sequentially in ascending order of the pages specified. In the case of a Tag equipped with I-CODE1, specify the write data in the order: F⇒0⇒1⇒···⇒A. Command ‘ 3‘ *1 Communications option Bank specification Page specification Write data*1 ‘3‘ … Data 1 Tag type Bank specification (Settable value) I-CODE1 ‘ 00 ‘ ISO chip ‘00’ to ‘0F’ Data n Page specification (settable value) ‘00’ to ‘FF’ ‘00’ to ‘FF’ Number of data n = Number of specified pages x 8 (hexadecimal) Number of data n = Number of specified pages x 4 (ASCII) Response The response returns the end code (normal end: ‘00’). End code ‘0‘ ‘0‘ Command Example The following table gives details of tag user memory when executing the following command. Page 10 Byte 0 30 Hex 34 Hex 38 Hex 40 Hex 44 Hex 48 Hex 4C Hex 50 Hex 30 Hex 30 Hex 30 Hex Byte 1 31 Hex 35 Hex 39 Hex 41 Hex 45 Hex 49 Hex 4D Hex 51 Hex 30 Hex 30 Hex 30 Hex Byte 2 32 Hex 36 Hex 30 Hex 42 Hex 46 Hex 4A Hex 4E Hex 52 Hex 30 Hex 30 Hex 30 Hex Byte 3 33 Hex 37 Hex 30 Hex 43 Hex 47 Hex 4B Hex 4F Hex 53 Hex 30 Hex 30 Hex 30 Hex (1) Writing 30303030 hexadecimal to pages 8, 9, and 10 using FIFO Trigger Mode with hexadecimal: Command ‘03 08 0700 30303030 ‘ Response ‘00 (2) Writing ‘0000’ to pages 8, 9, and 10 using FIFO Trigger Mode with ASCII: Command ‘03 18 0700 0000 ‘ Response ‘00 Data written to tag memory is the same for both (1) and (2). 4-13 4-3 Commands and Responses during CR Control Section 4-3 4) Read UID (SNR) Use this command to read the serial numbers from the tags. Command Command ‘3’ Communications option ‘5’ Response The response returns the UID (SNR) read and the end code (normal end: 00). End code ‘0‘ ‘0‘ UID (SNR) ・・・ Data 1 Data 8 5) Set write-protection to Tag Use this command to write-prohibit tags. The maximum number of pages that can be write-protected in a single operation is one bank, and write-protecting pages across banks is impossible. Command This command sends the pages to be write-protected as command data. The page specification is achieved by setting the bit corresponding to each page to ON. When performing reading only, all the page specifications are set to OFF. Command ‘3‘ Communications option Bank Page specification specification ‘9‘ Tag type Bank I・CODE1 ‘00’ ISO chip ‘00’ to ‘0F’ Page specification (settable value) ‘00’ to ‘FF’ ‘00’ to ‘FF’ Response The response returns the setting status for write-protection and the end code (normal end: '00'). End code ‘0‘ 4-14 ‘0‘ Setting status Page specification specification Bank 4-3 Commands and Responses during CR Control Section 4-3 4-3-3 Commands Specific to the I-CODESLI Chip 1) Write, Lock AFI Use this command to change or lock tag AFI. Command Communications option Command ‘3‘ Process option Data ‘6‘ Process option Data Write AFI 01 Hex AFI = 00 to FF(Hex) Lock AFI 02 Hex 00 Hex Response The response returns the end code (normal end: ‘00’). End code ‘0‘ ‘0‘ 2) Write, Lock DSFID Use this command to change or lock tag DSFID. Command Command ‘3‘ Communications option Process option Data ‘7‘ Process option Data Write DSFID 01 Hex AFI = 00 to FF(Hex) Lock DSFID 02 Hex 00 Hex Response The response returns the end code (normal end: ‘00’). End code ‘0‘ ‘0‘ 4-15 4-3 Commands and Responses during CR Control Section 4-3 3) Read Tag Info Use this command to read tag system information. Command Command ‘3’ Communications option ‘A’ Response The response returns the information flag, UID, the information data, and the end code (normal end: '00'). The data returned in the information data is changed with the information flag. End code ‘0‘ Information flag UID ‘0‘ Information ・・・ Data 1 Data 8 ・・・ Data 1 Data n ・Information flag Bit IC information Memory size AFI DSFID ・Information (variable data length) VICC memory size DSFID AFI Number of blocks Block length IC information *Only information with the bit set by the information flag is stored. *Number of blocks = 00h (1 block) to FFh (256 block) *Block length = 00h (1 byte) to 1Fh (32 byte) 4) Read UID & Data Use this command to read UID and data from the tags at the same time. Data can be read from a user-specified page. The maximum number of pages that can be read in one operation is one bank (16 pages), and reading pages across banks is impossible. Command This command sends the pages to be read as command data. The page specification is achieved by setting the bit corresponding to each page to ON. Command ‘4‘ Communications option Bank specification Page specification ‘1‘ Tag type Bank ISO chip 00 to 0F Page 8 7 Response The response returns the UID and data read and the end code (normal end: 00). The read data is returned sequentially in the order of the pages specified. End code ‘0‘ ‘0‘ UID Data 1 ・・・ Read data* Data 8 Data 1 ・・・ * Number of read data n = Number of specified pages × page unit (4 bytes) 4-16 Data n 4-3 Commands and Responses during CR Control Section 4-3 5) EAS Alarm Command Requests EAS data to the tags. Command Command ‘4‘ Communications option ‘2‘ Response The response returns the EAS data read and the end code (normal end: 00). End code ‘0‘ ‘0‘ EAS data ‘F4CD460EABE509FE178D011C4B81926E415B5961F6F5D10D8F398B48A54EECF7’ 6) Set EAS Enables/disables and locks EAS to the tags. Command Command ‘4‘ Communications option Process option Data ‘3‘ Process option Data Enable EAS 01 HEX 00 HEX: disabled/01 HEX: enabled Lock EAS 02 Hex 00 Hex Response The response returns the end code (normal end: ‘00’). End code ‘0‘ ‘0‘ 4-17 4-3 Commands and Responses during CR Control Section 4-3 4-3-4 Commands Specific to the I-CODE1 Chip 1) Read Serial Nnumber Use this command to read tag serial numbers. Command Command ‘0‘ ‘5‘ Response The response returns the tag serial number read, and the end code (normal end: '00'). End code ‘0‘ ‘0‘ Tag serial number Data 1 …… Data n The tag serial number is 16 digits in hexadecimal code. 2) Read Family Code and Application ID Use this command to read tag family codes and application IDs. Command Command ‘0‘ ‘6‘ Response The response returns the tag family code, application ID read, and end code (normal end: '00'). End code ‘0‘ ‘0‘ Family Code Application ID ‘00’ to ‘FF’ ‘00’ to ‘FF’ 3) Write Family Code and Application ID Use this command to set the tag family codes and application IDs. Command Command ‘0‘ ‘7‘ Family Code Application ID ‘00’ to ‘FF’ ‘00’ to ‘FF’ Response The response returns the end code (normal end: ‘00’). End code ‘0‘ 4-18 ‘0‘ 4-3 Commands and Responses during CR Control Section 4-3 4) Set EAS mode Use this command to set whether to permit or prohibit tag EAS responses. Command Command ‘0‘ Set value ‘8‘ Set value: ’ 00 ‘ ’ 01 ‘ Permit Prohibit Response The response returns the end code (normal end: ‘00’). End code ‘0‘ ‘0‘ 5) EAS Sends EAS commands to the tags. EAS data, which is the response from the tags, is fixed data, as shown below. Command Command ‘2‘ ‘4‘ Response EAS data ‘ 2FB36270D5A7907FE8B18038D281497682DA9A866FAF8BB0F19CD112A57237EF ‘ Note If there is no tag in the communications area, undefined data of 64 characters will be returned. 4-19 4-3 Commands and Responses during CR Control Section 4-3 4-3-5 Old Commands Specific to the I-CODE1 Chip The command can be replaced by Section 4 “Commands Common to the I-CODE1 and the I-CODESLI Chips”. 1) Read Use this command to read data from the tags. Data can be read from a user-specified page. Command This command sends the pages to be read as command parameters. The page specification is as follows: The bits that correspond to the pages to be read are set to 1, and all other bits are set to 0. This binary number is converted to hexadecimal and sent with the command. The pages are specified by the user. Command ‘0‘ Page specification (4 characters) Communications option ‘ 1‘ Bit Page Settable Value 2 1 A 9 ‘00’ to ‘FF’ ‘00’ to ‘FF’ Response The response returns the data read and the end code (normal end: ‘00’).The read data is returned sequentially in ascending order of the pages specified. If an error occurs, an error code is returned.In the case of a Tag equipped with I-CODE1, the read data is returned in the order: B⇒C⇒D⇒E⇒F⇒0⇒1⇒···⇒A. Read data*1 End code ‘0‘ ‘0‘ Data 1 ⋅⋅⋅⋅⋅⋅ Data n *1 Number of data n = Number of specified pages x 8 (hexadecimal) Number of data n = Number of specified pages x 4 (ASCII) The following table gives the tag user memory details for the following example of commands and responses. Page 10 Byte 0 30 Hex 34 Hex 38 Hex 40 Hex 44 Hex 48 Hex 4C Hex 50 Hex 54 Hex 58 Hex 62 Hex Byte 1 31 Hex 35 Hex 39 Hex 41 Hex 45 Hex 49 Hex 4D Hex 51 Hex 55 Hex 59 Hex 63 Hex Byte 2 32 Hex 36 Hex 30 Hex 42 Hex 46 Hex 4A Hex 4E Hex 52 Hex 56 Hex 5A Hex 64 Hex Byte 3 33 Hex 37 Hex 30 Hex 43 Hex 47 Hex 4B Hex 4F Hex 53 Hex 57 Hex 61 Hex 65 Hex (1) Reading the following four pages: 1, 3, 5, and 6, using Single Trigger Mode with hexadecimal is as follows: Command ‘01 00 006A ‘ Response ‘00 34353637 40414243 48494A4B 4C4D4E4F ‘ (2) Reading the following four pages: 1, 3, 5, and 6, using Single Trigger Mode with ASCII is as follows: Command ‘01 10 006A ‘ Response ‘00 4567 @ABC HIJK LMNO ‘ 4-20 4-3 Commands and Responses during CR Control Section 4-3 2) Write Use this command to write data to tags on a page basis. Data is written to user-specified pages. There is no need to perform the verify read process, since this command performs it as part of its execution. Command This command sends the data to be written as parameters. The page specification is as follows: The bits that correspond to the pages to be written are set to 1, and all other bits are set to 0. This binary number is converted to hexadecimal and sent with the command. Specify the write data sequentially in ascending order of the pages specified. In the case of a Tag equipped with I-CODE1, specify the write data in the order: F⇒0⇒1⇒···⇒A. Command ‘0‘ Write data*1 ‘2‘ Bit Page ⋅⋅⋅⋅⋅⋅ Data 1 Settable Value *1 Page specification (4 characters) Communications option 2 1 A 9 ‘ 00’ to ‘ 07 ‘ ‘ 10’ to ‘ 17 ‘ Data n ‘00’ to ‘FF’ Number of data n = Number of specified pages x 8 (hexadecimal) Number of data n = Number of specified pages x 4 (ASCII) Response The response returns the end code (normal end: ‘00’). End code ‘0‘ ‘0‘ The following table gives details of tag user memory when executing the following command. Page 10 Byte 0 30 Hex 34 Hex 38 Hex 40 Hex 44 Hex 48 Hex 4C Hex 50 Hex 52 Hex 58 Hex 56 Hex Byte 1 31 Hex 35 Hex 39 Hex 41 Hex 45 Hex 49 Hex 4D Hex 51 Hex 46 Hex 59 Hex 37 Hex Byte 2 32 Hex 36 Hex 30 Hex 42 Hex 46 Hex 4A Hex 4E Hex 52 Hex 49 Hex 5A Hex 32 Hex Byte 3 33 Hex 37 Hex 30 Hex 43 Hex 47 Hex 4B Hex 4F Hex 53 Hex 44 Hex 61 Hex 30 Hex (1) Writing 52464944 hexadecimal to page 8, and 56373230 hexadecimal to page 10 using FIFO Repeat Mode, with hexadecimal: Command ‘02 0B 0500 52464944 56373230 ‘ Response ‘00 (2) Writing ‘RFID’ hexadecimal to page 8, and ‘V720’ hexadecimal to page 10 using FIFO Repeat Mode, with ASCII: Command ‘02 1B 0500 RFID V720 ‘ Response ‘00 ‘ Data written to tag memory is the same for both (1) and (2). 4-21 4-3 Commands and Responses during CR Control Section 4-3 3) Write identical data Use this command to write identical data to tags by the page. Data is written to user-specified pages. This command is useful when writing the same data to multiple pages (specification is required only once). There is no need to perform the verify read process, since this command performs it as part of its execution. Command As parameters, the command sends specification of the pages to be written and the data to write to the specified pages one page at a time. The page specification is as follows: The bits that correspond to the pages to be written are set to 1, and all other bits are set to 0. This binary number is converted to hexadecimal and sent with the command. Specify the write data sequentially in ascending order of the pages specified. In the case of a Tag equipped with I-CODE1, specify the write data in the order: F⇒0⇒1⇒···⇒A. Command ‘0‘ Write data*1 ‘ 3‘ Bit Page ⋅⋅⋅⋅⋅⋅ Data 1 Settable Value *1 Page specification (4 characters) Communications option 2 1 A 9 ‘ 00’ to ‘ 07 ‘ ‘ 10’ to ‘ 17 ‘ Data n ‘00’ to ‘FF’ Number of data n = Number of specified pages x 8 (hexadecimal) Number of data n = Number of specified pages x 4 (ASCII) Response The response returns the end code (normal end: ‘00’). End code ‘0‘ ‘0‘ Command Example The following table gives details of tag user memory when executing the following command. Page 10 Byte 0 30 Hex 34 Hex 38 Hex 40 Hex 44 Hex 48 Hex 4C Hex 50 Hex 30 Hex 30 Hex 30 Hex Byte 1 31 Hex 35 Hex 39 Hex 41 Hex 45 Hex 49 Hex 4D Hex 51 Hex 30 Hex 30 Hex 30 Hex Byte 2 32 Hex 36 Hex 30 Hex 42 Hex 46 Hex 4A Hex 4E Hex 52 Hex 30 Hex 30 Hex 30 Hex Byte 3 33 Hex 37 Hex 30 Hex 43 Hex 47 Hex 4B Hex 4F Hex 53 Hex 30 Hex 30 Hex 30 Hex (1) Writing 30303030 hexadecimal to pages 8, 9, and 10 using FIFO Trigger Mode with hexadecimal: Command ‘03 08 0700 30303030 ‘ Response ‘00 4-22 4-3 Commands and Responses during CR Control Section 4-3 (2) Writing ‘0000’ to pages 8, 9, and 10 using FIFO Trigger Mode with ASCII: Command ‘03 18 0700 0000 ‘ Response ‘00 Data written to tag memory is the same for both (1) and (2). 4) Set lock Use this command to write-prohibit tags. Command This command sends the pages to be write-protected as command data. The page specification is as follows: The bits that correspond to the pages to be write-protected are set to 1, and all other bits are set to 0. This binary number is converted to hexadecimal and sent with the command. To read the current write-prohibit settings, set the page specification to '0000'. Page specification (4 characters) Command ‘0‘ ‘9‘ Bit Page Settable Value 2 1 A 9 Page B Hex and C Hex must be 0. ‘00’ to ‘FF’ Response The response returns the setting status for write-protection and the end code (normal end: '00'). The page specification is as follows: The bits that correspond to the write-protect pages are set to 1, and all other bits are set to 0. End code ‘0‘ ‘0‘ Bit Page Value Note Setting status 2 1 A 9 Page B Hex and C Hex are 0. ‘00’ to ‘FF’ The lock function used with the V720 Series cannot be canceled. Pages that have been write-protected cannot be written to again, so be careful when using this function. 4-23 SECTION 5 Characteristics Data (Reference) 5-1 5-2 5-3 5-3-1 5-3-2 5-4 5-5 5-6 Communications Distance (Reference)................................................................5-2 Diagram of Communications Range (Reference)................................................5-3 Communications Time (Reference) ......................................................................5-7 Communications time ............................................................................................5-7 TAT (Turn Around Time) ........................................................................................5-8 Effects of Surrounding Metal (Reference)............................................................5-9 Mutual Interference (Reference)............................................................................5-10 Positional Relation Between Rreader and Computer (Reference) ....................5-11 5-1 5-1 Communications Distance (Reference) 5-1 Section 5-1 Communications Distance (Reference) The communications distance is given in the following table. The communications distance changes, however, depending on the tag inlet forming material, and the tag and RFID Unit mounting conditions, so check the conditions of use beforehand. 1) I-CODE1 Tag Inlet Model Specifications Shape Communication distance (reference) V720-D52P03 Inlet φ21 2 to 19mm V720-D52P04 Inlet Rectangle 16.5x22 3 to 19mm 2) I-CODESLI Tag Inlet and Tag (available soon) Model V720S-D13P01 Inlet V720S-D13P02 Inlet V720S-D13P06 Inlet V720S-D13P30 Tag V720S-D13P40 Tag Note 5-2 Specifications Shape ISO card 46 x 76 Half 46 x 43 32 x 72 ISO card 46 x 76 ISO card 46 x 76 Communication distance (reference) 0 to 45 mm 0 to 36 mm 0 to 35 mm 0 to 62 mm 0 to 42 mm The communications distances shown above are based on the use of standard tags at a temperature of 25°C. 5-2 Diagram of Communications Range (Reference) Diagram of Communications Range (Reference) A diagram of the V720S-HMU01 communications range is given below. The communications range differs, however, depending on the mounting conditions and the environmental conditions. X and Y directions represented in the following diagrams correspond to each direction of X and Y directions shown with arrows in the following figure. Y direction (Gaining the distance from the RFID unit) X direction (Positive) X direction (Negative) Tag Read/Write unit 1) I-CODE1 Tag Tag: V720-D52P03 タ グ:V720-D52P01 80 70 y方向(mm) 60 Y direction (mm) 5-2 Section 5-2 25℃ 50℃ 0℃ 50 40 30 20 10 -80 -70 -60 -50 -40 -30 -20 -10 0 10 20 30 40 50 60 70 80 x方向(m m ) X direction (mm) 5-3 5-2 Diagram of Communications Range (Reference) Y direction (mm) Tag: V720-D52P04 X direction (mm) 2) I-CODESLI Tag Y direction (mm) Tag: V720S-D13P01 X direction (mm) 5-4 Section 5-2 5-2 Diagram of Communications Range (Reference) Section 5-2 Y direction (mm) Tag: V720S-D13P02 X direction (mm) Y direction (mm) Tag: V720S-D13P06 X direction (mm) 5-5 5-2 Diagram of Communications Range (Reference) Y direction (mm) Tag: V720S-D13P30 X direction (mm) Y direction (mm) Tag: V720S-D13P40 X direction (mm) 5-6 Section 5-2 5-3 Communications TIme (Reference) 5-3 Section 5-3 Communications Time (Reference) The communications time given below includes the communications time and TAT (Turn Around Time). Command 1 RFID Unit Command 2 V720 series Tag Computer V720S-HMU01 Response 1 Computer Response 2 Command 1 Response 1 Command 2 RFID Unit Response 2 Tag Communications Time TAT 5-3-1 Communications time The communications time is the communications processing time between the RFID Unit and the tags. The communications time differs depending on the number of pages being written or read. Specifying Number of Pages to Be Written/Read Continuously Formulas Command Communications time (ms) I-CODE 1 I-CODE SLI Read T = 1.3N + 6.2 T = 1.3N + 6.0 Write T = 13N + 13.5 T = 13.6N + 15.5 N: No. of pages processed Not Specifying Number of Pages to Be Written/Read Continuously Formulas Command I-CODE1 Communications time (ms) I-CODESLI Read T = 1.3NR + 6.2 T = 1.3NR +6.0 Write T = 11.7NW + 1.3NR + 13.5 T = 12.3NW + 1.3NR + 15.5 NR = (Maximum number of specified pages – minimum number of specified pages) + 1 NW = No. of pages written Note 5-7 When using I-CODE1 tags, convert the pages Bh through Fh in the system area as shown below: Page B ⇒ Page -5 Page C ⇒ Page -4 Page D ⇒ Page -3 Page E ⇒ Page -2 Page F ⇒ Page -1 When using I-CODESLI tags, calculate the page numbers by converting them into decimal numbers. 5-3 Communications Time (Reference) Section 5-3 Example: Reading data from pages 1, 5, and 9 T = 1.3 × ( 9 - 1 + 1 ) + 6.2 = 17.9 ms (for I-CODE1) T = 1.3 × (9 - 1 + 1 ) + 6.0 = 17.7 ms (for I-CODESLI) Example: Reading data from pages C, 5, and 9 T = 1.3 × (9-(-4)+1) + 6.2 = 24.4ms (for I-CODE1) T = 1.3 × (12-5+1) + 6.0 = 16.6ms (for I-CODESLI) Example: Writing data to pages 2, 4, 9, and 10 T = 11.7 × 4 + 1.3 × ( 10 - 2 + 1 ) + 13.5 = 72ms (for I-CODE1) T = 12.3 × 4 + 1.3 × ( 10 - 2 + 1 ) + 15.5 = 76.4ms (for I-CODESLI) Communications Time Calculation Conditions • Communications mode: Single Trigger Mode • Communications errors must not occur, such as due to noises. 5-3-2 TAT (Turn Around Time) The TAT is the time taken from when the host control unit sends a command to the RFID Unit, to when a response is received and completed. The time differs depending on the baud rate and the communications control method setting. Example of TAT Calculation Example: Reading from page 0 to page 4 I-CODE1 (1)During command send 9[char.] × 11 [bits] / 9600[bps] × 1000[ms/s] ≈ 10.32ms I-CODESLI (1)During command send 11[char.] × 11 [bits] / 9600[bps] × 1000[ms/s] ≈ 12.61ms (2)During communications 6.5 + 6.2 = 12.7ms (2)During communications 6.5 + 6.0 = 12.5ms (3)During reception of response 43[char.] × 11 [bits] / 9600[bps] × 1000[ms/s] ≈ 49.27ms (3)During reception of response 43[char.] × 11 [bits] / 9600[bps] × 1000[ms/s] ≈ 49.27ms The TAT in to the above example is (1) + (2) + (3) = 72.29 ms. The TAT in to the above example is (1) + (2) + (3) = 74.38 ms. The calculations are performed according to the following conditions. • Communications mode : Single Trigger Mode • Communications control method : CR control • Baud rate : 9,600 bps • Data code specification : Hexadecimal • Commands sent from the host control unit are sent continuously without spaces between the characters. • Communications errors must not occur, such as due to noises. 5-8 5-4 Effects of Surrounding Metal (Reference) 5-4 Section 5-4 Effects of Surrounding Metal (Reference) If there is a metal backing plate on the RFID Unit, communication distance with the tags will be reduced. The data given below is for aluminum and iron. Metal plate 30 Tag Communications distance reduction (%) V720S-HMU01 Iron 100 Aluminum 80 60 40 20 20 40 60 80 100 120 Distance from metal backing plate (mm) X: distance between Metal and plate Measuring conditions Aluminum: 300 × 300 × t1.5 mm Iron: 300 × 300 × t1.0 mm Note 5-9 Communication distance with tags may be reduced due to metallic materials used in the operating environment such as a table or desk. The effect varies depending on the material. Make sure how the material has impact on it before operation. 5-5 Mutual Interference (Reference) 5-5 Section 5-5 Mutual Interference (Reference) If using multiple RFID Units near each other, keep a distance as shown below to prevent malfunction due to mutual interference. Parallel Antennas 100 mm or more Facing Antennas 250 mm or more Note 5-10 Mutual interference depends on the operating environment of the RFID Unit and tags, so be sure to check the environment before operation. 5-6 (R f 5-6 Positional Relation Between Reader and Compu Section 5-6 Positional Relation Between Reader and Computer (Reference) To minimize the effect of noise caused by computer (or the power supply circuit), keep the RFID unit away from the area described as below. The radius of 150mm or more of the DC jack for external AC adaptor. 50mm or more 50mm or more Keep the RFID unit away from this area. 50mm or more When you use the reader with desktop computer, keep it away from the joint of AC power supply cord. Note Effects of noise depend on the operating environment of the RFID Unit and the computer, so be sure to check the environment before operation. 5-11 Section 6 Driver Installation 6-1 6-2 Before Installation ...............................................................................................6-1 Driver Installation .................................................................................................6-2 6-1 6-1 Before Installation 6-1 6-1 Before Installation This section describes how to install the specified device driver (called “Driver”), which has to be installed in the computer to operate the RFID unit (V720S-HMU01). This Driver appears as a virtual COM port on the computer. [System Requirements] Make sure the computer to be connected with the RFID unit meets the system requirements for running the Driver as below. ●OS: Windows XP home/Professional or Windows 2000 Professional. ●USB port available (USB1.0 or USB2.0) ●The specified Driver installable. ●An administrator of the computer shall install the Driver. [How to obtain the Driver] Visit our Web site (http://www.omronrfid.com/) and download the Driver from the download page. If you download the Driver, the compressed file of V720S-HMU01.exe is stored in the computer. Note: The Driver must be installed before connecting the RFID unit to your computer. If you happen to connect the RFID unit to the computer before installation of the Driver, cancel the connection then start to install referring to “If you connect before installing” described in the end of this section. An administrator of the computer shall install the Driver. 6-2 Driver Installation [Decompression of the Driver] (1) Run the V720S-HMU01(E).exe downloaded from the Web site mentioned above. (2) The following dialog appears. 6-2 6-2 Driver Installation 6-2 (3) If you change the direction of the decompressed file, click “Change” then click “OK”. If you do not change the direction, just click “OK”. (4) The folder V720S-HMU01 appears in the directed folder. If you do not change the direction, the folder V720S-HMU01 appears in the same folder as V720S-HMU01.exe is placed. V720S-HMU01 folder includes following two folders, driver <= In this folder, the Driver is stored. utility <= Utilities to be used for identification of port numbers are stored. [Driver Installation] (1) Double click the setup.exe in the driver folder to start the installation process. (2) When the Install Driver dialog appears, click “Install”. If you use Windows XP SP2 or later version, the following page appears. On this page, click “Continue” to go back to the Install Driver page. This warning page appears twice. On each page, click “Continue”. If you use Windows 2000, this page does not appear. (3) Install Driver page appears again and installation is processed. Then, on the setup page, click OK to complete the install process. 6-3 6-2 Driver Installation 6-2 [Connection with RFID Unit] After installing the Driver, connect the RFID unit (V720S-HMU01) to the computer through USB connector. (1) Just after connecting the RFID unit to the computer, following page appears. (2) On the “Found New Hardware Wizard” page, Click “No, not this time” and then click “Next”. If you use the Windows 2000, this page is automatically skipped and the following page appears. (3) On the second “Found New Hardware Wizard” page, make sure “Install the software automatically [Recommended]” is checked then click the “Next” button. 6-4 6-2 Driver Installation 6-2 (4) When the “Hardware Installation” page appears over the third “Found New Hardware Wizard” page, click the “Continue” button. (5) On the last “Found New Hardware Wizard” page, click “Finish” button to complete the wizard. Now you are able to use the RFID unit. Caution ● Above pages shown from (1) to (5) appear twice because two software; USB Bridge software and Virtual COM software, have to be installed. In each time, implement in the same way according to the above procedures. 6-5 6-2 Driver Installation 6-2 [If you connect RFID unit before installing the Driver] If you connect the RFID unit to the computer before installing the Driver, you can not set up the Driver in the usual manner. After connecting the unit to the computer, one of following pages will appear. See which page appears on your computer window and follow the procedures corresponding to the page. (1) On the page as below, click the “Cancel” button and then remove the RFID unit. Start Driver installation according to the procedures described at the beginning of this section. (2) On the page as below, click the “Cancel” button and then remove the RFID unit. Start Driver installation according to the procedures described at the beginning of this section. 6-6 6-2 Driver Installation 6-2 (3) On the page as below, click the “Cancel” button and then remove the RFID unit. Start Driver installation according to the procedures described at the beginning of this section. If you have clicked the “Finish” on the page below, go to (4). (4) If you happen to click the “Finish” button, you have to delete the device. To delete the device, open the System Property window then click Hardware tab. On the Hardware page, click “Device Manager”. 6-7 6-2 Driver Installation 6-2 (5) On the Device Manager page, make sure OMRON V720S-HMU01 appears under the “Other Device”. (6) Point the OMRON V720S-HMU01 and click the right mouse button to open drop-down menu. Choose the “Delete” in the menu to complete deletion. After deleting the device, remove the RFID unit, then start to install the Driver again. [To See Port Number] Find the disPort.exe file in the utility folder that is extracted from the driver file, V720S-HMU01.exe. Click the disPort.exe file. Following dialogue appears. You can check what port number is assigned for the RFID unit (In the case of above dialogue, COM3: is assigned.) Caution ● Execution of dispPort.exe requires another file CP210xManufacturing.dll in the same folder. If you copy or move the dispPort.exe to use it, copy or move the CP210xManufacturing.dll file into the same place. 6-8 Revision History A manual revision code appears as a suffix to the manual number on the front cover of the manual. Manual No. SRFM-017A Revision code The following table outlines the changes made to the manual during each revision. Page numbers refer to the previous version. Revision code Date Dec, 2007 Revised content The first edition OMRON CORPORATION RFID BUSINESS DEVELOPMENT DEPARTMENT 3-4-10 Toranomon Minato-ku, Tokyo, 105-0001 Japan Tel: (81)3-3436-7317/ Fax: (81)3-3436-7387 Regional Headquarters OMRON ELECTRONICS LLC RFID DIVISION One Commerce Drive, Schaumburg, IL 60173 U.S.A. Tel: (1)888-303-RFID (7343) /Fax: (1)847-925-1260 OMRON EUROPE B.V. Wegalaan 57, NL-2132 JD Hoofddorp The Netherlands Tel: (31)23-568-1200/Fax: (31)23-568-1222 OMRON ASIA PACIFIC PTE. LTD. 83 Clemenceau Avenue, #11-01, UE Square, 239920 Singapore Tel: (65)835-3011/Fax: (65)835-2711 OMCC: OMRON (CHINA) CO., LTD. Rm.302, AZIA Center, 1233 Lujiazui Ring Road Pudong New Area, Shanghai 200120, PRC. Tel: (86)21-5888-1666 Fax: (86)21-58888-7633/7933 Up-to-date information on RFID Systems can be accessed at OMRON's web site at http://www.omronrfid.com/ Authorized Distributor: Manual No. SRFM017A Note: Specifications subject to change without notice. Printed in Japan
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.5 Linearized : No Page Count : 68 XMP Toolkit : XMP toolkit 2.9.1-14, framework 1.6 About : uuid:22098adc-b846-4a5f-8c3b-0447aba3de56 Modify Date : 2007:12:10 20:30:51+09:00 Create Date : 2007:12:10 20:30:49+09:00 Metadata Date : 2007:12:10 20:30:51+09:00 Document ID : uuid:32d03678-d965-44c1-86eb-31d61550ce8d Format : application/pdf Creator : PScript5.dll Version 5.2 Producer : Acrobat Distiller 6.0.1 (Windows)EXIF Metadata provided by EXIF.tools