Omron 6CYSIDV6800308 RFID System User Manual Z262 E1 04
Omron Corporation RFID System Z262 E1 04
Omron >
Contents
- 1. Manual 1
- 2. Manual 2
Manual 1
RFID System V680 Series User's Manual for Amplifiers, Antennas, and ID Tags (EEPROM) Amplifier and Antennas V680-HA63A V680-HS51 V680-HS52 V680-HS63 V680-HS65 V680-H01-V2 ID Tags V680-D1KP52MT V680-D1KP66T V680-D1KP66MT V680-D1KP66T-SP V680-D1KP58HT Cat. No.: Z262-E1-04 Introduction Thank you for purchasing a V680-series RFID System. This manual describes the functions, performance, and application methods needed for optimum use of the V680-series RFID System. Please observe the following items when using the RFID System. • Allow the RFID System to be installed and operated only by qualified specialist with a sufficient knowledge of electrical systems. • Read and understand this manual before attempting to use the RFID System and use the RFID System correctly. • Keep this manual in a safe and accessible location so that it is available for reference when required. READ AND UNDERSTAND THIS DOCUMENT Product Overview Section 2 Specifications and Performance Section 3 Communications Specifications Section 4 Installation Section 5 Chemical Resistance RFID System V680-HA63A V680-HS51 V680-HS52 V680-HS63 V680-HS65 V680-H01-V2 V680-D1KP52MT V680-D1KP66T V680-D1KP66MT V680-D1KP66T-SP V680-D1KP58HT Amplifier Antenna Antenna Antenna Antenna Antenna ID Tag ID Tag ID Tag ID Tag ID Tag User's Manual Section 1 Section 2 Section 3 Section 4 Section 5 Section 1 Introduction Introduction Introduction Introduction READ AND UNDERSTAND THIS DOCUMENT Please read and understand this document before using the products. Please consult your OMRON representative if you have any questions or comments. WARRANTY OMRON’s exclusive warranty is that the products are free from defects in materials and workmanship for a period of one year (or other period if specified) from date of sale by OMRON. OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, REGARDING NON-INFRINGEMENT, MERCHANTABILITY, OR FITNESS FOR PARTICULAR PURPOSE OF THE PRODUCTS. ANY BUYER OR USER ACKNOWLEDGES THAT THE BUYER OR USER ALONE HAS DETERMINED THAT THE PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE. OMRON DISCLAIMS ALL OTHER WARRANTIES, EXPRESS OR IMPLIED. LIMITATIONS OF LIABILITY OMRON SHALL NOT BE RESPONSIBLE FOR SPECIAL, INDIRECT, OR CONSEQUENTIAL DAMAGES, LOSS OF PROFITS OR COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED ON CONTRACT, WARRANTY, NEGLIGENCE, OR STRICT LIABILITY. In no event shall responsibility of OMRON for any act exceed the individual price of the product on which liability is asserted. IN NO EVENT SHALL OMRON BE RESPONSIBLE FOR WARRANTY, REPAIR, OR OTHER CLAIMS REGARDING THE PRODUCTS UNLESS OMRON’S ANALYSIS CONFIRMS THAT THE PRODUCTS WERE PROPERLY HANDLED, STORED, INSTALLED, AND MAINTAINED AND NOT SUBJECT TO CONTAMINATION, ABUSE, MISUSE, OR INAPPROPRIATE MODIFICATION OR REPAIR. SUITABILITY FOR USE THE PRODUCTS CONTAINED IN THIS DOCUMENT ARE NOT SAFETY RATED. THEY ARE NOT DESIGNED OR RATED FOR ENSURING SAFETY OF PERSONS, AND SHOULD NOT BE RELIED UPON AS A SAFETY COMPONENT OR PROTECTIVE DEVICE FOR SUCH PURPOSES. Please refer to separate catalogs for OMRON's safety rated products. OMRON shall not be responsible for conformity with any standards, codes, or regulations that apply to the combination of products in the customer’s application or use of the product. At the customer’s request, OMRON will provide applicable third party certification documents identifying ratings and limitations of use that apply to the products. This information by itself is not sufficient for a complete determination of the suitability of the products in combination with the end product, machine, system, or other application or use. The following are some examples of applications for which particular attention must be given. This is not intended to be an exhaustive list of all possible uses of the products, nor is it intended to imply that the uses listed may be suitable for the products: • Outdoor use, uses involving potential chemical contamination or electrical interference, or conditions or uses not described in this document. • Nuclear energy control systems, combustion systems, railroad systems, aviation systems, medical equipment, amusement machines, vehicles, safety equipment, and installations subject to separate industry or government regulations. • Systems, machines, and equipment that could present a risk to life or property. Please know and observe all prohibitions of use applicable to the products. NEVER USE THE PRODUCTS FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY WITHOUT ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT THE OMRON PRODUCT IS PROPERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM. PERFORMANCE DATA Performance data given in this document is provided as a guide for the user in determining suitability and does not constitute a warranty. It may represent the result of OMRON’s test conditions, and the users must correlate it to actual application requirements. Actual performance is subject to the OMRON Warranty and Limitations of Liability. CHANGE IN SPECIFICATIONS Product specifications and accessories may be changed at any time based on improvements and other reasons. It is our practice to change model numbers when published ratings or features are changed, or when significant construction changes are made. However, some specifications of the product may be changed without any notice. When in doubt, special model numbers may be assigned to fix or establish key specifications for your application on your request. Please consult with your OMRON representative at any time to confirm actual specifications of purchased products. DIMENSIONS AND WEIGHTS Dimensions and weights are nominal and are not to be used for manufacturing purposes, even when tolerances are shown. ERRORS AND OMISSIONS The information in this document has been carefully checked and is believed to be accurate; however, no responsibility is assumed for clerical, typographical, or proofreading errors, or omissions. PROGRAMMABLE PRODUCTS OMRON shall not be responsible for the user’s programming of a programmable product, or any consequence thereof. COPYRIGHT AND COPY PERMISSION This document shall not be copied for sales or promotions without permission. This document is protected by copyright and is intended solely for use in conjunction with the product. Please notify us before copying or reproducing this document in any manner, for any other purpose. If copying or transmitting this document to another, please copy or transmit it in its entirety. RFID System User's Manual Introduction Introduction Safety Precautions Alert Symbols for Safe Use The following symbols are used in this manual to indicate precautions that must be observed to ensure safe use of the V680-HS51, V680-HS52, V680-HS63, V680-HS65, V680-H01-V2, V680-HA63A, V680D1KP52MT, V680-D1KP66T, V680-D1KP66MT, V680-D1KP66T-SP, and V680-D1KP58HT. The precautions provided here contain important safety information. Be sure to observe these precautions. The following signal words are used in this manual. WARNING Indicates a potentially hazardous situation which, if not avoided, will result in minor or moderate injury, or may result in serious injury or death. Additionally, there may be significant property damage. Meanings of Alert Symbols Indicates general prohibitions for which there is no specific symbol. Warning WARNING These Products are not designed to be used either directly or indirectly in applications that detect human presence for the purpose of maintaining safety. Do not use these Products as a sensing means for protecting human lives. Regulations and Standards The Products conform to the following overseas regulations and standards. 1.The United States Amplifier Antenna This product complies with Part 15 Subpart C of the FCC Rules. FCC ID: E4E6CYSIDV6800406 V680-HA63A This product complies with Part 15 Subpart C of the FCC Rules. FCC ID: E4E6CYSIDV6800308 --- V680-HS51 V680-HS52 V680-HS63 V680-HS65 V680-H01-V2 FCC NOTICE This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference. (2) This device must accept any interference received, including interference that may cause undesired operation. FCC WARNING Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. Do not remove the ferrite core (TDK Type ZCAT1730-0730A:V680-HS52/-HS63/-HS65, TDK Type ZCAT15250430AP:V680-HS51, TDK Type ZCAT2035-0930:V680-H01-V2) installed on the cables to suppress RF interference. RFID System User's Manual Introduction Introduction 2. Europe Amplifier (Radio and Telecommunication Terminal Equipment Directive 1999/5/EC) V680-HA63A Radio: EMC: EN 300 330-2 EN 301 489-1 EN 301 489-3 Safety: EN 61010 --- Antenna V680-HS51 V680-HS52 V680-HS63 V680-HS65 V680-H01-V2 English Hereby, Omron, declares that the RFID System, V680-HS51 Series, V680-HS52 Series, V680-HS63 Series, V680-HS65 Series, V680-H01-V2 Series and V680-HA63A Series are in compliance with the essential requirements and other relevant provisions of Directive 1999/5/EC. Finnish Omron vakuuttaa täten että RFID Säännös, V680-HS51 Series, V680-HS52 Series, V680-HS63 Series, V680-HS65 Series, V680-H01-V2 Series, V680HA63A Series tyyppinen laite on direktiivin 1999/5/EY oleellisten vaatimusten ja sitä koskevien direktiivin muiden ehtojen mukainen. Dutch Hierbij verklaart Omron dat het toestel de RFID Systeem, V680-HS51 ´Serie, V680-HS52 ´Serie, V680-HS63 ´Serie, V680-HS65 ´Serie, V680-H01-V2 ´Serie, V680-HA63A ´Serie in overeenstemming is met de essentiële eisen en de andere relevante bepalingen van richtlijh 1999/5/EG. French Par la présente Omron déclare que la RFID Système, V680-HS51 Série, V680-HS52 Série, V680-HS63 Série, V680-HS65 Série, V680-H01-V2 Série, V680-HA63A Série sont conforme aux exigences essentielles et aux autres dispositions pertinentes de la directive 1999/5/CE. Swedish Härmed intygar Omron att den RFID System, V680-HS51 Serie, V680-HS52 Serie, V680-HS63 Serie, V680-HS65 Serie, V680-H01-V2 Serie, V680HA63A Serie stär l överensstämmelse med de väsentliga egenskapskrav och övriga relevanta bestämmelser som framgår av direktiv 1999/5/EG. Danish Undertegnede Omron erklærer herved, at følgende den RFID System, V680-HS51 Serie, V680-HS52 Serie, V680-HS63 Serie, V680-H01-V2 Serie, V680-HS65 Serie, 680-HA63A Serie overholder de væsentlige krav og øvrige relevante krav i direktiv 1999/5/EF. German Hiermit erklärt Omron, die RFID System, V680-HS51 Serie, V680-HS52 Serie, V680-HS63 Serie, V680-HS65 Serie, V680-H01-V2 Serie, V680-HA63A Serie in Übereinstimmung mit den grundlegenden Anforderungen und den anderen relevanten Vorschriften der Richtlinie 1999/5/EG befindet. (BMWi) Greek ME THN ΠAPOYSA Omron ΔHΛONEI RFID O’YO’ΓΗΜΑ, V680-HS51 O’EIPA, V680-HS52 O’EIPA, V680-HS63 O’EIPA, V680-HS65 O’EIPA, V680H01-V2 O’EIPA, V680-HA63A O’EIPA SYMMOPF ONETAI ΠPOS TIS OYSIOΔEIS AΠAITHSEIS KAI TIS ΛOIΠES SXETIKES ΔIATAΞEIS THS OΔHΓIAS 1999/5/EK. Italian Con la presente Omron dichiara che la RFID Sistema, V680-HS51Serie, V680-HS52Serie, V680-HS63 Serie,V680-HS65 Serie,V680-H01-V2 Serie, V680-HA63A Serie sono conforme ai requisiti essenziali ed alle altre disposizioni pertinenti stabilite dalla direttiva 1999/5/CE. Spanish Por medio de la presente Omron declara que el RFID Sistema, V680-HS51 Serie, V680-HS52 Serie, V680-HS63 Serie, V680-HS65 Serie, V680-H01-V2 Serie, V680-HA63A Serie esta conforme a los requisitos esenciales y cualesquiera otras disposiciones aplicables o exigibles de la Directiva 1999/5/CE. Portuguese Omron declara que a RFID Sistema, V680-HS51 Série, V680-HS52 Série, V680-HS63 Série, V680-HS65 Série, V680-H01-V2 Série, V680-HA63A Série ser conforme com os tequisitos essenciais e outras disposições da Directiva 1999/5/CE. Romanian Prin prezenta, Omron declar c acest V680-HS51, V680-HS52, V680-HS63, V680-HS65, V680-H01-V2, V680-HA63A este conform cu cerin ele principale çi cu celelalte prevederi relevanate ale Directivei 1999/5/EC. 3. Japan Amplifier Antenna Equipment using high frequencies: Inductive Reading/Writing Communications Equipment V680-HA63A V680-HS51 Conforming standards: Inductive Reading/Writing Communications Equipment; Standard: ARIB STD-T82 V680-HS52 EC-06019 V680-HS63 V680-HS65 Equipment using high frequencies: Inductive Reading/Writing Communications Equipment Conforming standards: Inductive Reading/Writing Communications Equipment; Standard: ARIB STD-T82 EC-@@@@@ --- V680-H01-V2 4. Canada Amplifier Antenna IC ID:850J-V68HA63A V680-HA63A V680-HS51 V680-HS52 V680-HS63 V680-HS65 IC ID:850J-V6800308 --- V680-H01-V2 This device complies with RSS-Gen of IC Rules. Operation is subject to the following two conditions:(1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. RFID System User's Manual Introduction Introduction 5. China Amplifier Antenna CMII ID:2008DJ0884 V680-HA63A V680-HS51 CMII ID:2007DJ0577 V680-HA63A V680-HS52-R CMII ID:2007DJ0575 V680-HA63A V680-HS52-W CMII ID:2007DJ0571 V680-HA63A V680-HS63-R CMII ID:2007DJ0573 V680-HA63A V680-HS63-W CMII ID:2008DJ0141 V680-HA63A V680-HS65-R CMII ID:2008DJ0142 V680-HA63A V680-HS65-W 6. Korea Amplifier OMR-V680-HA63A V680-HA63A Antenna V680-HS51 V680-HS52 V680-HS63 V680-HS65 7. Taiwan Amplifier CCAB07LP1220T4 V680-HA63A Antenna V680-HS51 V680-HS52 V680-HS63 V680-HS65 RFID System User's Manual Introduction Introduction 8. Hong Kong Amplifier LP407043 V680-HA63A Antenna V680-HS52 V680-HS63 9. Singapore Amplifier S0294-07 V680-HA63A Antenna V680-HS51 V680-HS52 V680-HS63 V680-HS65 10.Malaysia Amplifier A011578 V680-HA63A Antenna V680-HS51 V680-HS52 V680-HS63 V680-HS65 If the product is used in Malaysia, a label must be attached on-site to the side of the V680-HA63A. Please consult your OMRON sales representative for details. 11.Philippine Amplifier ESD-0702971C V680-HA63A Antenna V680-HS51 V680-HS52 V680-HS63 V680-HS65 12.Mexico Amplifier COFETEL:RLVOMV607-622-A2 V680-HA63A Antenna V680-HS51 V680-HS52 V680-HS63 V680-HS65 Este equipo opera a titulo secundario, consecuentemente, debe aceptar interferencias perjudiciales incluyendo equipos de la misma clase y puede no causar interferencias a sistemas operando a titulo primario. 13.Thailand The certification is unnecessary, so the product can be used. Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. Do not remove the ferrite core (TDK Type ZCAT1730-0730A:V680-HS52/-HS63/-HS65, TDK Type ZCAT15250430AP:V680-HS51, TDK Type ZCAT2035-0930:V680-H01-V2) installed on the cables to suppress RF interference. RFID System User's Manual Introduction Introduction Precautions for Safe Use Be sure to observe the following precautions to ensure safe use of the Products. 1. Do not use the Products in environments with flammable, explosive, or corrosive gasses. 2. Do not attempt to disassemble, repair, or modify any Product. 3. Tighten mounting screws securely. 4. Because a cable has a locking mechanism, make sure that it has been locked before using the cable. 5. Do not allow water or pieces of wire to enter from openings in the case. Doing so may cause fire or electric shock. 6. Turn OFF the Controller power supply before mounting or removing an Antenna or Amplifier. 7. Turn OFF the power supply to the Controller before changing settings. Attach a Setting switch protection Cover after setting Switch. 8. If an error is detected in any Product, immediately stop operation and turn OFF the power supply. Consult with an OMRON representative. 9. Dispose of the Products as industrial waste. 10. Observe all warnings and precautions given in the body of this manual. 11. Do not touch the product immediately after usage at high temperatures. Doing so may occasionally result in burning. 12. Do not open the back cover of the V680-H01-V2 antenna. 13. Do not install the Products near equipment that generates a large amount of heat, such as a heater, transformer, or high-capacity resistor. RFID System User's Manual Introduction Introduction Precautions for Correct Use Always observe the following precautions to prevent operation failures, malfunctions, and adverse effects on performance and equipment. 1. Installation Environment Do not use the Products in the following locations. • Locations exposed to direct sunlight • Locations exposed to corrosive gases, dust, metallic powder, or salts • Locations not within the specified operating temperature range • Locations subject to rapid changes in temperature or condensation • Locations not within the specified humidity range • Locations subject to direct vibration or shock outside the specified ranges • Locations subject to spray of water, oil, or chemicals 2. Installation The Products communicate with Tags using the 13.56-MHz frequency band. Some motors, inverters, and switching power supplies generate noise that can affect communications with the Tags and cause errors. If such devices are located near the Tags, always test operation in advance to confirm whether the system will be affected. • Observe the following precautions to minimize the effects of normal noise. (1) Ground all metal objects in the vicinity of the Products to 100 Ω or less. (2) Do not use the Products near high-voltage or high-current lines. • Do not use non-waterproof Products in an environment where mist is present. • Do not expose the Products to chemicals that adversely affect the Product materials. • When mounting the Products, tighten the screws to the following torques. V680-HS51: 6 N⋅m V680-HS52: 40 N⋅m V680-HS63: 1.2 N⋅m V680-HS65: 1.2 N⋅m V680-H01-V2: 1.2 N⋅m • Do not pull the Antenna connector over the power of 30 N. The Antenna connector may be broken. • Transmission will not be possible if the front and back panels are mistakenly reversed and the Unit is mounted to a metallic surface. V680-D1KP66MT • The transmission distance will be reduced when the Unit is not mounted to a metallic surface. V680-D1KP66MT • If multiple Antennas are mounted near each other, communications performance may decrease due to mutual interference. Refer to Installing Antennas on page 56 and check to make sure there is no mutual interference. • Depending on the operating environment, the case surface may become fogged, but basic performance will not be affected. RFID System User's Manual Introduction Introduction 3. Storage Do not store the Products in the following locations. • Locations exposed to direct sunlight • Locations exposed to corrosive gases, dust, metallic powder, or salts • Locations not within the specified storage temperature range • Locations subject to rapid changes in temperature or condensation • Locations not within the specified storage humidity range • Locations subject to direct vibration or shock outside the specified ranges • Locations subject to spray of water, oil, or chemicals 4. Cleaning • Do not clean the Products with paint thinner or the equivalent. Paint thinner, benzene, acetone, and kerosene or the equivalent will dissolve the resin materials and case coating. 5. Combination of the Amplifier • Use the V680-D1KP52MT, V680-D1KP66T, V680-D1KP66MT, and V680-D1KP66T-SP ID Tags in combination with only the V680-HA63A Amplifier. Do not use these ID Tags together with the V680HA63B Amplifier. RFID System User's Manual Introduction Introduction Meanings of Symbols 10 Meanings of Symbols Indicates particularly important points related to a function, including precautions and application advice. Indicates page numbers containing relevant information. RFID System User's Manual Introduction Introduction Table of Contents Safety Precautions Regulations and Standards Precautions for Safe Use Precautions for Correct Use Meanings of Symbols 10 Table of Contents 11 Section 1 Product Overview 13 Features 14 Product Configuration 15 Section 2 Specifications and Performance 17 Antennas with Separate Amplifier 18 Antennas with Built-in Amplifier 25 Amplifier 30 Tags 33 Section 3 Communications Specifications 43 Communications Distances 44 Communication Time (Reference) 53 Section 4 Installation 55 Installing Antennas 56 Mounting Amplifiers 65 Installing Tags 67 Section 5 Chemical Resistance 79 Chemical Resistance of the Antennas 80 Chemical Resistance of Tags 81 Degree of Protection 85 Revision History 88 RFID System User's Manual 11 Introduction Introduction 12 MEMO RFID System User's Manual Section 1 Section 1 Product Overview 14 Product Configuration 15 RFID System User's Manual Product Overview Features 13 Section 1 Product Overview Features The V680-series RFID System actively supports many different types of system, such as distributed-control Section 1 Features systems and many-product, small-lot production systems, with non-contact data communications using electromagnetic induction. Non-contact Data Communications The V680 Series uses electromagnetic induction to enable non-contact, bi-directional data communications between Antennas and Tags. EEPROM Memory EEPROM (non-volatile memory) is used for Tag memory. No battery is required, so there is no need to be concerned about battery service life. CRC Used for Transmission Error Detection A bi-directional 16-bit CRC (Cyclic Redundancy Check) has been added as the error detection method for wire transmissions between ID Controllers and Antennas, and for wireless transmissions between Antennas and Tags. This method maintains superior communications reliability even where problems such as noise occur. 1,000byte of Memory Tags have 1,000byte of memory. In addition to the ID data required on-site, data such as model numbers and inspection information can be input. Long Service Life of 100,000 Data Rewrites at Normal Temperatures When the Tag is used at temperatures of up to 25°C, each block of EEPROM data can be rewritten up to 100,000 times (in units of single block, 8-bytes). Superior Environmental Resistance and High Reliability Antennas and Tags now have greater environmental resistance and are not affected by vibration, oil, or water. 14 RFID System User's Manual Section 1 Product Overview Product Configuration A V680-series RFID System consists of an ID Controller, one or more Amplifiers, one or two Antennas, and Section 1 Product Configuration Tags. Select the models suitable for the application. Using Antennas with Separate Amplifiers Programmable Controller (SYSMAC CS/CJ Series) Host device Personal computer RS-232C RS-422 RS-485 CS1W-V680C11/12 V680-CA5D02-V ID Controller ID Sensor Units V680-CA5D01-V V68 0C1 RUN1 ERC NOR ERP ERH T/R M/ER V68 0C1 RUN2 ERC HEA D1 T/R ERP ERH HEA T/R D2 NOR M/ER CJ1W-V680C11/12 NOR M/ER TES TES ON ON HEA D1 HEA D1 DC2 INP 4V UT HEA D2 Antennas with Separate Amplifier Amplifiers V680-HA63A V680-HS51 V680-HS63 V680-D1KP66T V680-D1KP66MT V680-HS65 V680-D1KP66T-SP Tags V680-D1KP52MT V680-HS52 When embedding the V680-D1KP52MT into a metal surface, use the V680-HS51, V680-HS52 Antenna. Transmission will not be possible if the V680-HS63 Antenna is used. Use the V680-D1KP52MT, V680-D1KP66T, V680-D1KP66MT, and V680-D1KP66T-SP ID Tags in combination with only the V680-HA63A Amplifier, Do not use these ID Tags together with the V680-HA63B Amplifier. RFID System User's Manual 15 Section 1 Product Overview Using a V680-H01-V2 Antenna with Built-in Amplifier Programmable Controller (SYSMAC CS/CJ Series) Section 1 Product Configuration Host device Personal computer RS-232C RS-422 RS-485 CS1W-V680C11 ID Controller ID Sensor Units V680-CA5D01-V V700-A40-W CJ1W-V680C11 V68 0C1 RUN1 ERC NOR ERP ERH T/R M/ER TES ON HEA D1 Cable * Always use the specified Cable to connect a V680-H01-V2 Antenna. The V680-H01-V2 Antenna cannot be connected without using the specified Cable. Antennas with Built-in Amplifier V680-H01-V2 Tags V680-D1KP58HT 16 RFID System User's Manual Section 2 Specifications and Performance Section 2 18 Antennas with Built-in Amplifier 25 Amplifier 30 Tags 33 RFID System User's Manual Specifications and Performance Antennas with Separate Amplifier 17 Section 2 Specifications and Performance Antennas with Separate Amplifier V680-HS51 General Specifications Item Model V680-HS51 Section 2 Antennas with Separate Amplifier Ambient operating temperature −10 to 60°C (with no icing) Ambient storage temperature −25 to 75°C (with no icing) Ambient operating humidity 35% to 95% (with no condensation) Insulation resistance 20 MΩ min. (at 500 VDC) between connector terminals and case Dielectric strength 1,000 VAC, 50/60 Hz for 1 min between connector terminals and case Degree of protection IP67.(IEC60529) In-house standard for antenna oil resistance (former JEM standard equivalent to IP67g) Note: The connectors are not waterproof. Dielectric strength 10 to 2,000 Hz, 1.5-mm double amplitude, acceleration: 150 m/s2, 10 sweeps in each of 3 axis directions (up/down, left/right, and forward/backward) for 15 minutes each Shock resistance 1,000 m/s2, 3 times each in 6 directions (Total: 18 times) Dimensions M12 × 35 mm Material ABS resin, brass, and epoxy resin filler Weight Approx. 55 g Cable length Standard lengths of 2 m Dimensions • V680-HS51 12.5 (Unit : mm) dia. Toothed washer 26.2 12 M12 × 1 Connector Ferrite core Two lock nuts Mounting Hole Dimensions 24 33 35 Coaxial cable, 2.9 dia., standard length: 2 m (16.8 dia.) 50 25 (14.5 dia.) 17 9.6 dia. 21 dia 15 Insulation cover 18 RFID System User's Manual Case material Brass Communications surface ABS resin Fill resin Epoxy resin Cable PVC (black) Section 2 Specifications and Performance V680-HS52 General Specifications Item Model V680-HS52-W (Standard cable, waterproof connector) V680-HS52-R (Flexible cable, non-waterproof connector) −10 to 60°C (with no icing) Ambient storage temperature −25 to 75°C (with no icing) Ambient operating humidity 35% to 95% (with no condensation) Insulation resistance 20 MΩ min. (at 500 VDC) between connector terminals and case Dielectric strength 1,000 VAC, 50/60 Hz for 1 min between connector terminals and case Degree of protection IP67.(IEC60529) In-house standard for antenna oil resistance (former JEM standard equivalent to IP67g) Note: The connector specifications are IP67 and IP65.(IEC60529) Dielectric strength 10 to 500 Hz, 1.5-mm double amplitude, acceleration: 100 m/s2, 10 sweeps in each of 3 axis directions (up/down, left/right, and forward/backward) for 8 minutes each Shock resistance 500 m/s2, 3 times each in 6 directions (Total: 18 times) Dimensions M22 × 65 mm Material ABS resin, brass, and epoxy resin filler Weight Approx. 850 g (with 12.5 m cable) Cable length Standard lengths of 2 and 12.5 m Section 2 Antennas with Separate Amplifier Ambient operating temperature IP67.(IEC60529) In-house standard for antenna oil resistance (former JEM standard equivalent to IP67g) Note: The connectors are not waterproof. Dimensions • V680-HS52-W 22.5 dia. Two toothed washers Two lock nuts Mounting Hole Dimensions M22 × 1 Ferrite core Operation indicator 37 16.5 dia. 30 Connector 14.5 dia. 19.8 dia. 35 dia. 30 47.6 50 57 65 16.5 dia. Antenna 50 Insulation cover Coaxial cable, 5.5 dia., standard length: 2 m Case material Brass Communications surface ABS resin Fill resin Epoxy resin Cable PVC (gray) RFID System User's Manual 19 Section 2 Specifications and Performance • V680-HS52-R 22.5 dia. Two toothed washers Two lock nuts Mounting Hole Dimensions (39.5) 35 dia. 30 14.5 dia. 16.5 dia. 30 47.6 50 57 65 RFID System User's Manual Insulation cover Connector 16.5 dia. Ferrite core Operation indicator Antenna 19.8 dia. Section 2 Antennas with Separate Amplifier 20 M22 × 1 50 Coaxial cable, 5.3 dia., standard length: 2 m Insulation cover Case material Brass Communications surface ABS resin Fill resin Epoxy resin Cable PVC (black) Section 2 Specifications and Performance V680-HS63 General Specifications Item Model V680-HS63-W (Standard cable, waterproof connector) −10 to 60°C (with no icing) Ambient storage temperature −25 to 75°C (with no icing) Ambient operating humidity 35% to 95% (with no condensation) Insulation resistance 20 MΩ min. (at 500 VDC) between cable terminals and case Dielectric strength 1,000 VAC, 50/60Hz for 1 min between cable terminals and case Degree of protection IP67.(IEC60529) In-house standard for antenna oil resistance (former JEM standard equivalent to IP67g) Note: The connector specifications are IP67 and IP65.(IEC60529) Vibration resistance 10 to 500 Hz, 1.5-mm double amplitude, acceleration: 100 m/s2, 10 sweeps in each of 3 axis directions (up/down, left/right, and forward/backward) for 11 minutes each Shock resistance 500 m/s2, 3 times each in 6 directions (Total: 18 times) Dimensions 40 × 53 × 23 mm Material ABS resin case, epoxy resin filler Weight Approx. 850 g (with 12.5 m cable) Cable length Standard lengths of 2 and 12.5 m Section 2 Antennas with Separate Amplifier Ambient operating temperature V680-HS63-R (Flexible cable, non-waterproof connector) IP67.(IEC60529) In-house standard for antenna oil resistance (former JEM standard equivalent to IP67g) Note: The connectors are not waterproof. Dimensions • V680-HS63-W Antenna (Unit: mm) Ferrite core 30 53 16.5 dia. 14.5 dia. 27 16.5 dia. 40 28±0.1 37 Connector 50 Insulation cover Coaxial cable, 5.5 dia., standard length: 2 m 11 23 Operation indicator Note: Mounting Hole Dimensions Two, M4 or 4.5 dia. holes Coil center Case material ABS resin Fill resin Epoxy resin Cable PVC (gray) RFID System User's Manual 21 Section 2 Specifications and Performance V680-HS63-R Antenna Ferrite core 30 53 RFID System User's Manual 50 Coaxial cable, 5.3 dia., standard length: 2 m Insulation cover 11 Operation indicator Note: Mounting Hole Dimensions Coil center 16.5 dia. 16.5 dia. 14.5 dia. 40 28±0.1 27 23 Section 2 Antennas with Separate Amplifier 22 (39.5) (Unit: mm) Connector Two, M4 or 4.5 dia. holes Case material ABS resin Fill resin Epoxy resin Cable PVC (black) Section 2 Specifications and Performance V680-HS65 General Specifications Item Model V680-HS65-W (Standard cable, waterproof connector) V680-HS65-R (Flexible cable, non-waterproof connector) −25 to 70°C (with no icing) Ambient storage temperature −40 to 85°C (with no icing) Ambient operating humidity 35% to 95% (with no condensation) Insulation resistance 20 MΩ min. (at 500 VDC) between connector terminals and case Dielectric strength 1,000 VAC, 50/60 Hz for 1 min between connector terminals and case Degree of protection IP67 (IEC60529) In-house standard for antenna oil resistance (former JEM standard equivalent to IP67g) Note: The connector specifications are IP67 and IP65 (IEC 60529). Dielectric strength 10 to 500 Hz, 1.5-mm double amplitude, acceleration: 100 m/s2, 10 sweeps in each of 3 axis directions Section 2 Antennas with Separate Amplifier Ambient operating temperature IP67 (IEC60529) In-house standard for antenna oil resistance (former JEM standard equivalent to IP67g) Note: The connectors are not waterproof. (up/down, left/right, and forward/backward) for 11 minutes each Shock resistance 500 m/s2, 3 times each in 6 directions (Total: 18 times) Dimensions 100 × 100 × 30 mm Material ABS resin case, epoxy resin filler Weight Approx. 1100 g (with 12.5 m cable) Cable length Standard lengths of 2 and 12.5 m Dimensions • V680-HS65-W 4-4.5 dia. (Mounting holes) 50 Operation indicator (Unit: mm) 100 90±0.2 Ferrite core Connector 50 37 16.5 dia. 16.5 dia. 100 90±0.2 14.5 dia. 25 Bushing 30 10 50 10 20 30 14 Coaxial cable, 5.5 dia., standard length: 2 m Insulation cover 11 Case material ABS resin Fill resin Epoxy resin Cable PVC (gray) RFID System User's Manual 23 Section 2 Specifications and Performance V680-HS65-R 4-4.5 dia. (Mounting holes) 50 Operation indicator (Unit: mm) 100 90±0.2 Ferrite core 50 Bushing 30 10 20 30 User's Manual 50 10 14 RFID System 16.5 dia. 14.5 dia. 16.5 dia. 100 90±0.2 Section 2 Antennas with Separate Amplifier 24 Connector (39.5) 25 Coaxial cable, 5.3 dia., standard length: 2 m Insulation cover 11 Case material ABS resin Fill resin Epoxy resin Cable PVC (black) Section 2 Specifications and Performance Antennas with Built-in Amplifier V680-H01-V2 General Specifications Item Model V680-H01-V2 −10 to 55°C (with no icing) Ambient storage temperature −35 to 65°C (with no icing) Ambient operating humidity 35% to 85% (with no condensation) Insulation resistance 20 MΩ min. (at 100 VDC) between connector terminals and the rear plate Dielectric strength 1,000 VAC, 50/60 Hz for 1 min between connector terminals and the rear plate Degree of protection IP63.(IEC60529); Mounting direction: Communications surface facing up Dielectric strength 10 to 150 Hz, 0.35-mm single amplitude, acceleration: 50 m/s2, 10 sweeps in each of 3 axis directions (up/down, left/right, and forward/backward) for 8 minutes each Shock resistance 150 m/s2, 3 times each in 6 directions (Total: 18 times) Cable length 0.5 m (use an extension cable to connect to the Controller up to 30.5 m) LED indicators RUN, COMM, NORM, ERR, CNT-TYPE, TAG-TYPE, Error Code, Level Weight Approx. 900 g Section 2 Antennas with Built-in Amplifier Ambient operating temperature Communications Specifications Item Model V680-H01-V2 Communications method Electromagnetic induction Operating frequency 13.56 MHz ± 7KHz Modulation ASK RFID System User's Manual 25 Section 2 Specifications and Performance Dimensions MOUNTING SCREW HOLES (Unit : mm) Connector Vinyl Insulated Round Cord (5.8-dia.) (41/0.16-dia.) 2 Cores (17/0.08-dia.) 8 Cores Standard Length 0.5 m 142.5 235±0.2 Four, M4 or 4.5-dia. holes Twelve, Operation Indicator Four, 5-dia. holes (Mounting Holes) Communications sufrace 14 64.8 20-dia. 185 (25-dia.) 200 Ferrite Core 65 Section 2 Antennas with Built-in Amplifier 185±0.2 Senter of Coil 50 Four, Mounting bracket Setting switch protection Cover 30 38 142.5 235 7.5 (17) +50 500 13.5 40 (1) 250 26 RFID System User's Manual Case material PC/ASA resin Rear Panel Aluminum Cable PVC (45) Section 2 Specifications and Performance Operation Indicator name Color Meaning RUN Green Lit when the power is ON. COMM Yellow Lit when a command is being sent. NORM Green Lit when communications with a Tag are normal in Normal Communications Mode. ERR Red Section 2 Antennas with Built-in Amplifier Lit when an error occurs in communications with a Tag in Normal Communications Mode. CNT-TYPE Yellow Lit when in V680-CA@D Controller connection mode (SW1-1 setting: ON). TAG-TYPE Yellow For expansion (not used): Always OFF. LV6/7D Yellow Maintenance Mode: Lit at distance or speed level 6. Normal Communications Mode: Lit when a write protection error occurs. LV5/7A Yellow Maintenance Mode: Lit at distance or speed level 5 or higher. Normal Communications Mode: Lit when an address error occurs. LV4/76 Yellow Maintenance Mode: Lit at distance or speed level 4 or higher. Normal Communications Mode: Lit when a Tag memory error occurs. LV3/72 Yellow Maintenance Mode: Lit at distance or speed level 3 or higher. Normal Communications Mode: Lit when a no Tag error occurs. LV2/71 Yellow Maintenance Mode: Lit at distance or speed level 2 or higher. Normal Communications Mode: Lit when a verification error occurs. LV1/70 Yellow Maintenance Mode: Lit at distance or speed level 1 or higher. Normal Communications Mode: Lit when a Tag communications error occurs. The distance level will vary greatly depending on the surrounding environment. The setting position will serve as a guide, but use RUN mode to conduct a sufficient number of tests in the actual operating environment. Values of distance level 4 or above may not be displayed, but this will not affect the RUN mode performance and does not indicate a malfunction. Differences between the V680-H01 and the V680-H01-V2 As shown in the following table, the V680-H01-V2 provides additional indicators. Turn ON SW1-1(Antenna) when using the V680-CA1D/CA2D. display functions RUN (POWER/COMM) V680-H01-V2 V680-H01 SW1-1: OFF SW1-1: ON no switch OK OK OK COMM (POWER/COMM) OK OK OK NORM OK NO NO ERR OK NO NO CNT-TYPE OK OK NO TAG-TYPE --- --- --- LV6/7D OK NO NO LV5/7A OK NO NO LV4/76 OK NO NO LV3/72 OK NO NO LV2/71 OK NO NO LV1/70 OK NO NO RFID System User's Manual 27 Section 2 Specifications and Performance Setting Switch Section 2 Antennas with Built-in Amplifier Setting switch protection cover Note: Please attach a setting switch protection cover after setting switch. Setting Function Default setting SW1-1 Controller selection OFF:V680-CA5D01-V@, CS1W-V680C11, or CJ1W-V680C11 ON: V680-CA1D/-CA2D OFF SW1-2 Reserved by System (Always set this Switch to OFF.) --- SW1-3 Reserved by System (Always set this Switch to OFF.) --- SW1-4 Reserved by System (Always set this Switch to OFF.) --- Set SW1-1 on the V680-H01-V2 Antenna and the Controller as shown in the following table. Antenna setting V680-H01-V2 Controller setting V680-CA5D01-V@ CS1W-V680C11 CJ1W-V680C11 V680-CA1D V680-CA2D SW1-1: OFF SW4-8: OFF DM20000 + 100 × m+3=0000 SW1-1: ON SW4-8: ON See Note. DM20000 + 100 × m+3=0001 See Note. See Note. : Cannot be used. : Can be used.(Controller setting not required.) Note: The high-speed mode cannot be used by the controller's setting. Differences between the V680-H01 and the V680-H01-V2 As shown in the following table, the V680-H01-V2 supports additional maintenance functions. Turn ON SW1-1(Antenna) when using the V680-CA1D/CA2D. display functions 28 RFID System User's Manual V680-H01-V2 V680-H01 SW1-1: OFF SW1-1: ON no switch Communication Test Mode OK OK OK Noise Level Measurement Mode OK NO NO Distance Level Measurement Mode OK NO NO Speed Level Measurement Mode OK NO NO Communications Success Rate Measurement Mode OK NO NO Section 2 Specifications and Performance Cables (V680-H01-V2 exclusive use) Specifications Item Model V700-A40-W Number of conductors 10 Insulation resistance 5 MΩ min. (at 500 VDC) between terminals and sheath Dielectric strength 500 VAC, 1 min Section 2 Antennas with Built-in Amplifier Dimensions Item Model Length (L1) Weight L1 V700-A40-W 2M V700-A40-W 5M V700-A40-W 10M V700-A40-W 20M V700-A40-W 30M Approx.2m Approx. 5 m Approx.10m Approx. 20 m Approx. 30 m Approx. 150 g Approx.360 g Approx. 700 g Approx.1,350 g Approx.2,000 g 2,000 5,000 10,000 20,000 30,000 (Unit: mm) 49 L1±100 20 dia. 15 dia. 41.8 Connector (Controller end)) Connector (Antenna end)) Connection label Vinyl Insulated Round Cord Cable 6 dia. PVC RFID System User's Manual 29 Section 2 Specifications and Performance Amplifier V680-HA63A General Specifications Item Model V680-HA63A Section 2 Amplifier Ambient operating temperature −10 to 55°C (with no icing) Ambient storage temperature −25 to 65°C (with no icing) Ambient operating humidity 35% to 85% (with no condensation) Insulation resistance 20 MΩ min. (at 500 VDC) between cable terminals and case Dielectric strength 1,000 VAC, 50/60 Hz for 1 minute between cable terminals and case. Degree of protection IP67, IP65 (IEC 60529) Note: Not including connector at Controller end. (When V680-HS52-W, V680-HS63-W, and V680-HS65-W is connected) Dielectric strength 10 to 500 Hz, 1.5-mm double amplitude, acceleration:100 m/s2, 10 sweeps in each of 3 axis directions (up/down, left/right, and forward/backward) for 11 minutes each Shock resistance 500 m/s2, 3 times each in 6 directions (Total: 18 times) Dimensions 25 × 40 × 65 mm (Not including protrusions.) Materials PC Weight Approx. 650 g (with 10 m cable) Cable length Standard lengths of 5 and 10 m IP40 (IEC 60529) (When V680-HS51, V680-HS52-R, V680HS63-R, and V680-HS65-R is connected) Note: The maximum total cable extension is 50 m (including the Amplifier cable). A maximum of two extension cables can be connected. Dimensions 65 18 30 25 40 25 9.5 dia. Connector RFID System User's Manual 36 35.6 3.5 Connector 15 25 51 15 dia. 13.7 12.8 dia. Operation indicator Round, vinyl-insulated cable (5.8 dia.), standard length: 5 m, (41/0.16 dia) 2 conductors, (17/0.08 dia.) 8 conductors Case material PC resin Cable PVC Section 2 Specifications and Performance Nomenclature Antenna with Separate Amplifier connection port Operation indicators Section 2 Amplifier RUN COMM NORM ERR LV6/7D LV5/7A LV4/76 LV3/72 LV2/71 LV1/70 Controller connector Antenna Connection Port The Antenna connection port is connected a V680-series Antenna. Controller Connector The Controller connector is connected to Antenna connection port on the Controller. Operation Indicators (LEDs) Name Color RUN Green Lit when the power is ON. COMM NORM Yellow Meaning Lit when a command is being sent. Green Lit when communications with a Tag are normal in Normal Communications Mode. ERR Red Lit when an error occurs in communications with a Tag in Normal Communications Mode. LV6/7D Yellow Maintenance Mode: Lit at distance or speed level 6. Normal Communications Mode: Lit when a write protection error occurs. LV5/7A Yellow Maintenance Mode: Lit at distance or speed level 5 or higher. Normal Communications Mode: Lit when an address error occurs. LV4/76 Yellow Maintenance Mode: Lit at distance or speed level 4 or higher. Normal Communications Mode: Lit when a Tag memory error occurs. LV3/72 Yellow Maintenance Mode: Lit at distance or speed level 3 or higher. Normal Communications Mode: Lit when a no Tag error occurs. LV2/71 Yellow Maintenance Mode: Lit at distance or speed level 2 or higher. Normal Communications Mode: Lit when a verification error occurs. LV1/70 Yellow Maintenance Mode: Lit at distance or speed level 1 or higher. Normal Communications Mode: Lit when a Tag communications error occurs. The distance level will vary greatly depending on the surrounding environment. The setting position will serve as a guide, but use RUN mode to conduct a sufficient number of tests in the actual operating environment. Values of distance level 4 or above may not be displayed, but this will not affect the RUN mode performance and does not indicate a malfunction. RFID System User's Manual 31 Section 2 Specifications and Performance Cables (V680-HA63 exclusive use) Specifications Item Model V700-A43/V700-A44 Number of conductors 10 Insulation resistance 5 MΩ min. (at 500 VDC) between terminals and sheath Dielectric strength 500 VAC, 1 min Item Model Length (L1) Weight V700-A43 V700-A44 Approx.10m Approx. 20 m Approx. 700 g Approx.1,350 g L1±100 49 6 dia. 15 dia. 51 15.5 dia. Section 2 Amplifier Dimensions Connector (Amplifier end) Connector (Controller end)) Connection label (Unit: mm) Cable 32 RFID System User's Manual PVC Section 2 Specifications and Performance Tags Specifications and Dimensions V680-D1KP52MT • General Specifications Model V680-D1KP52MT 1,000 bytes (user area) Memory type EEPROM Data backup time 10 years after writing (85°C or less), 0.5 years after writing (85°C to 125°C) Total data backup time at high temperatures exceeding 125°C is 10 houres (See note.) Memory longevity 100,000 times per block (25°C) Ambient operating temperature −25 to 85°C (with no icing) Ambient storage temperature −40 to 125°C (with no icing) Ambient operating humidity 35% to 95% Degree of protection IP68 (IEC 60529) In-house standard for antenna oil resistance (former JEM standard equivalent to IP67g) Vibration resistance 10 to 2,000 Hz, 1.5-mm double amplitude, acceleration: 150 m/s2, 10 sweeps each in X, Y, and Z directions for 15 minutes each Shock resistance 500 m/s2, 3 times each in X, Y, and Z directions (Total: 18 times) Dimensions 8 dia. × 5 mm Materials Case: PPS resin, Fill resin: Epoxy resin Weight Approx. 0.5 g Metal countermeasures Yes Section 2 Tags Item Memory capacity Note: After string data at high temperatures, rewrite the data even if changes are not required, In this manual, high temperatures are those exceeding 125°C up to 180°C. • Dimensions R0.2 8 −0.1 dia. 5 −0.1 (Unit : mm) Case material PPS resin Fill resin Epoxy resin When embedding the V680-D1KP52MT into a metal surface, use the V680-HS51, V680-HS52 Antenna. Transmission will not be possible if the V680-HS63 Antenna is used. The side with the markings is the communications surface. Mount the Tag with this side facing the Antenna. The ID code is written in the memory of the Tag and may be affected by data retention characteristics at high temperatures. Take suitable precautions when using the READ ID command for Tags operating at high temperatures. RFID System User's Manual 33 Section 2 Specifications and Performance V680-D1KP66T/66MT • General Specifications Item Model V680-D1KP66T V680-D1KP66MT Section 2 Tags Memory capacity 1,000 bytes (user area) Memory type EEPROM Data backup time 10 years after writing (85°C or less), 0.5 years after writing (85°C to 125°C) Total data backup time at high temperatures exceeding 125°C is 10 houres (See note.) Memory longevity 100,000 times per block (25°C) Ambient operating temperature −25 to 85°C (with no icing) Ambient storage temperature −40 to 125°C (with no icing) Ambient operating humidity 35% to 95% Degree of protection IP68 (IEC 60529) In-house standard for antenna oil resistance (former JEM standard equivalent to IP67g) Vibration resistance 10 to 2,000 Hz, 1.5-mm double amplitude, acceleration: 150 m/s2,10 sweeps each in X, Y, and Z directions for 15 minutes each Shock resistance 500 m/s2, 3 times each in X, Y, and Z directions (Total: 18 times) Dimensions 34 × 34 × 3.5 mm Materials Case: PPS resin Weight Approx. 6 g Approx. 7.5 g Metal countermeasures None Yes Note: After string data at high temperatures, rewrite the data even if changes are not required, In this manual, high temperatures are those exceeding 125°C up to 180°C. The V680-D1KP66MT is designed to be mounted directly to metal. The V680-D1KP66T and V680D1KP66MT markings are shown in the following diagrams. V680-D1KP66MT V680-D1KP66MT V680-D1KP66T V680-D1KP66T XXXXXX XXXXXX MADE IN JAPAN MADE IN JAPAN The side with the markings is the communications surface. Mount the Tag with this side facing the Antenna. The ID code is written in the memory of the Tag and may be affected by data retention characteristics at high temperatures. Take suitable precautions when using the READ ID command for Tags operating at high temperatures. 34 RFID System User's Manual Section 2 Specifications and Performance • Dimensions V680-D1KP66T/66MT Four, R4 34 Four, R3 25+0.2 32 Mounting Hole Dimensions 25+0.2 Two, M3 25+0.2 Section 2 Tags Two, 3.5 dia. Two, 6 dia. 32 25+0.2 3.5+0.1 34 Case material PPS resin V600-A86 Attachment Four, R5.5 25+0.2 Two, 4 dia. Two, M3 37 34 15 25+0.2 16 25+0.2 25+0.2 15 34 3.5 37 10 Case material PPS resin Tag Heat Resistivity • Storing Tags under high temperatures will adversely affect the performance of the internal parts and the service life of the Tags. • An LTPD of 10% was determined during the evaluation for Tags that reached the end of their life after testing under the following test conditions. Heat cycle −10°C/+150°C, 30 minutes each for 1,000 cycles −100°C/+180°C,30 minutes each for 200 cycles High temperatures +150°C, 1,000 hours +180°C, 200 hours LTPD: Lot tolerance percent defective The lower limit of the malfunction rate for lots to be considered unacceptable during reliability testing. RFID System User's Manual 35 Section 2 Specifications and Performance V680-D1KP66T-SP • General Specifications Item Model V680-D1KP66T-SP Memory capacity 1,000 bytes (user area) Memory type EEPROM Data backup time 10 years after writing (85°C or less) Section 2 Tags Memory longevity 100,000 times per block (25°C) Ambient operating temperature when communicating −25 to 70°C (with no icing) Ambient operating temperature when not communicating −40 to110°C (with no icing) Ambient storage temperature −40 to 110°C (with no icing) Ambient operating humidity 35% to 95% Degree of protection IP67 Vibration resistance 10 to 2,000 Hz, 1.5-mm double amplitude, acceleration: 150 m/s2,10 sweeps each in X, Y, and Z directions for 15 minutes each Shock resistance 500 m/s2, 3 times each in X, Y, and Z directions (Total: 18 times) Dimensions 95 × 36.5 × 6.5 mm (excluding protruding parts) Materials External coatiog: Fluororesin (PFA) Tag body: PPS resin Weight Approx. 20 g Mounting method Two M5 screws Metal countermeasures None • Dimensions Four, R6 34 Two, 5.5 dia. (Mounting hole) (Unit: mm) Mounting Hole Dimensions Two, M5 36.5 34 80±0.2 1.3 6.5 2.5 max. 80±0.2 Case material PFA resin 95 The side with the markings is the communications surface. Mount the Tag with this side facing the Antenna. 36 RFID System User's Manual Section 2 Specifications and Performance V680-D1KP58HT • General Specifications Item Model V680-D1KP58HT 1,000 bytes (user area) Memory type EEPROM Data backup time 10 years after writing (85°C or less), 2 years after writing (85°C to 110°C) Total data backup time at high temperatures exceeding 110°C is 10 houres (See note.) Memory longevity 100,000 times per block (25°C) Ambient operating temperature −10 to 85°C (with no icing) Ambient storage temperature −40 to 110°C (with no icing) Degree of protection IP67 (IEC 60529) Vibration resistance 10 to 2,000 Hz, 1.5-mm double amplitude, acceleration: 150 m/s2,10 sweeps each in X, Y, and Z directions for 15 minutes each Shock resistance 500 m/s2, 3 times each in X, Y, and Z directions (Total: 18 times) Materials Coatiog: PPS resin Weight Approx. 90 g Section 2 Tags Memory capacity Note: After string data at high temperatures, rewrite the data even if changes are not required, In this manual, high temperatures are those exceeding 110°C up to 200°C. The maximum operating temperature during communication is 85°C. The temperature of the actual Tag must not be higher than 85°C when the Tag enters the Antenna's communications area. When using a Tag after storage at high temperature, perform tests before use, and make sure that the temperature of the Tag does not exceed 85°C during operation. RFID System User's Manual 37 Section 2 Specifications and Performance • Tag Heat Resistivity • Storing Tags under high temperatures will adversely affect the performance of the internal parts and the service life of the Tags. • An LTPD of 10% was determined during the evaluation for Tags that reached the end of their life after testing under the following test conditions • Heat cycle: Room temperature/200ÅãC, 30 minutes each for 2,000 cycles. Section 2 Tags • Normal operation has been confirmed after performing the above tests, although minor cracks may occur. LTPD: Lot tolerance percent defective The lower limit of the malfunction rate for lots to be considered unacceptable during reliability testing. • Reference Data (Evaluation Test Results) Heat Resistance Evaluation Results Defective Operation 10% 9% Room temp. / 180 Room temp. / 200 Room temp. / 220 Defective rate(%) 8% , 30min each , 30min each , 30min each 7% 6% 5% 4% 3% 2% 1% 0% 500 1000 1500 2000 Number of cycles 38 RFID System User's Manual 2500 3000 3500 4000 Section 2 Specifications and Performance • Dimensions V680-D1KP58HT (Unit: mm) 10±0.2 60 dia. 5° 5° 80 dia Section 2 Tags 14 dia Case material PPS resin Two, R2 The side with the markings is the communications surface. Mount the Tag with this side facing the Antenna. V680-A80 (Attachment) This Attachment is specifically designed to secure V680-D1KP58HT Tags to the workpiece. Applicable Tag model: V680-D1KP58HT 17 (Unit: mm) 20 dia. 12 dia. M12 3.2 dia. M12 11.5 15 50 40 Mounting Hole Dimensions 110 Provided Parts Nuts (M12): Split pin (3.2 × 20 mm): 1 RFID System User's Manual 39 Section 2 Specifications and Performance Memory Map Data Address Section 2 Tags 0000 0001 0002 0003 03E6 03E7 User area 1 byte EEPROM is used as memory in the Tags. The memory capacity available to the user is 1,000 bytes, including 0000H to 0003H (the Write Protection Setting Area). The access to the memory is executed at every block. 1 block is 8 bytes (8 addresses). 40 RFID System User's Manual Section 2 Specifications and Performance Write Protection Function The write protection function prevents important data, such as product information, stored in memory in a Tag from being inadvertently overwritten. After important data has been written to memory, it can be write-protected using the following method. The write protection function can be switched with SW4-7 (Write Protection Function Setting) of the V680-CA5D@@-V@ Controller or with word (Write Protection Function Setting) in the DM(m+2)CH Area words allocated to the C@1W- Section 2 Tags V680C@@ ID Sensor Unit. Setting the Write Protection Function Write protection is set in Tag addresses 0000H to 0003H. The setting for the most significant bit of address 0000H specifies whether or not write protection is enabled. Address Bit YES/ NO 0000H Upper two digits of start address (00H to 7FH) 0001H Lower two digits of start address (00H to FFH) 0002H Upper two digits of end address (00H to FFH) 0003H Lower two digits of end address (00H to FFH) • Write-protect Bit (Most significant bit of address 0000H) 1: Write-protected (Yes) 0: Not write-protected (No) • Write Protection Setting Area Start address: 0000H to 7FFFH End address: 0000H to FFFFH Write Protection Setting Examples • Settings to write-protect addresses 0008H through 03E7H: Address Bit 0000H 0001H 0003H 0002H • Settings to not write-protect any addresses: Address 0000H 0001H 0002H 0003H Bit The write protection function is a function of the V680-CA5D@@-V@ Controller and the C@1W-V680C@@ ID Sensor Unit. It is not supported by reader/writer units from other manufacturers. RFID System User's Manual 41 Section 2 Specifications and Performance MEMO Section 2 Tags 42 RFID System User's Manual
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.4 Linearized : No Modify Date : 2008:10:15 15:23:51+09:00 Create Date : 2008:10:15 15:23:25+09:00 Title : Z262-E1-04 Author : OMRON Creator : FrameMaker 7.0 Producer : Acrobat Distiller 8.1.0 (Windows) Page Count : 44 Mod Date : 2008:10:15 15:23:51+09:00 Creation Date : 2008:10:15 15:23:25+09:00 Metadata Date : 2008:10:15 15:23:51+09:00 Has XFA : NoEXIF Metadata provided by EXIF.tools