Omron 6CYSIDV6800308 RFID System User Manual Z262 E1 04

Omron Corporation RFID System Z262 E1 04

Contents

Manual 1

Download: Omron 6CYSIDV6800308 RFID System User Manual Z262 E1 04
Mirror Download [FCC.gov]Omron 6CYSIDV6800308 RFID System User Manual Z262 E1 04
Document ID1017907
Application ID4/Zm9bDPdbQt8TbhjoL9EQ==
Document DescriptionManual 1
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize168.88kB (2111011 bits)
Date Submitted2008-10-20 00:00:00
Date Available2008-10-20 00:00:00
Creation Date2008-10-15 15:23:25
Producing SoftwareAcrobat Distiller 8.1.0 (Windows)
Document Lastmod2008-10-15 15:23:51
Document TitleZ262-E1-04
Document CreatorFrameMaker 7.0
Document Author: OMRON

RFID System
V680 Series
User's Manual for Amplifiers, Antennas, and ID Tags
(EEPROM)
Amplifier and Antennas
V680-HA63A
V680-HS51
V680-HS52
V680-HS63
V680-HS65
V680-H01-V2
ID Tags
V680-D1KP52MT
V680-D1KP66T
V680-D1KP66MT
V680-D1KP66T-SP
V680-D1KP58HT
Cat. No.: Z262-E1-04
Introduction
Thank you for purchasing a V680-series RFID System. This manual describes the functions, performance,
and application methods needed for optimum use of the V680-series RFID System.
Please observe the following items when using the RFID System.
• Allow the RFID System to be installed and operated only by qualified specialist with a sufficient
knowledge of electrical systems.
• Read and understand this manual before attempting to use the RFID System and use the RFID System correctly.
• Keep this manual in a safe and accessible location so that it is available for reference when required.
READ AND UNDERSTAND THIS DOCUMENT
Product Overview
Section 2
Specifications and Performance
Section 3
Communications Specifications
Section 4
Installation
Section 5
Chemical Resistance
RFID System
V680-HA63A
V680-HS51
V680-HS52
V680-HS63
V680-HS65
V680-H01-V2
V680-D1KP52MT
V680-D1KP66T
V680-D1KP66MT
V680-D1KP66T-SP
V680-D1KP58HT
Amplifier
Antenna
Antenna
Antenna
Antenna
Antenna
ID Tag
ID Tag
ID Tag
ID Tag
ID Tag
User's Manual
Section 1 Section 2 Section 3 Section 4 Section 5
Section 1
Introduction
Introduction
Introduction
Introduction
READ AND UNDERSTAND THIS DOCUMENT
Please read and understand this document before using the products. Please consult your OMRON representative if you have any questions or comments.
WARRANTY
OMRON’s exclusive warranty is that the products are free from defects in materials and workmanship for a period of one year (or other period if specified)
from date of sale by OMRON.
OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, REGARDING NON-INFRINGEMENT, MERCHANTABILITY, OR FITNESS FOR PARTICULAR PURPOSE OF THE PRODUCTS. ANY BUYER OR USER ACKNOWLEDGES THAT THE BUYER OR USER ALONE HAS
DETERMINED THAT THE PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE. OMRON DISCLAIMS ALL OTHER
WARRANTIES, EXPRESS OR IMPLIED.
LIMITATIONS OF LIABILITY
OMRON SHALL NOT BE RESPONSIBLE FOR SPECIAL, INDIRECT, OR CONSEQUENTIAL DAMAGES, LOSS OF PROFITS OR COMMERCIAL LOSS IN
ANY WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED ON CONTRACT, WARRANTY, NEGLIGENCE, OR STRICT LIABILITY.
In no event shall responsibility of OMRON for any act exceed the individual price of the product on which liability is asserted.
IN NO EVENT SHALL OMRON BE RESPONSIBLE FOR WARRANTY, REPAIR, OR OTHER CLAIMS REGARDING THE PRODUCTS UNLESS OMRON’S
ANALYSIS CONFIRMS THAT THE PRODUCTS WERE PROPERLY HANDLED, STORED, INSTALLED, AND MAINTAINED AND NOT SUBJECT TO CONTAMINATION, ABUSE, MISUSE, OR INAPPROPRIATE MODIFICATION OR REPAIR.
SUITABILITY FOR USE
THE PRODUCTS CONTAINED IN THIS DOCUMENT ARE NOT SAFETY RATED. THEY ARE NOT DESIGNED OR RATED FOR ENSURING SAFETY OF
PERSONS, AND SHOULD NOT BE RELIED UPON AS A SAFETY COMPONENT OR PROTECTIVE DEVICE FOR SUCH PURPOSES. Please refer to
separate catalogs for OMRON's safety rated products.
OMRON shall not be responsible for conformity with any standards, codes, or regulations that apply to the combination of products in the customer’s application or use of the product.
At the customer’s request, OMRON will provide applicable third party certification documents identifying ratings and limitations of use that apply to the products. This information by itself is not sufficient for a complete determination of the suitability of the products in combination with the end product, machine,
system, or other application or use.
The following are some examples of applications for which particular attention must be given. This is not intended to be an exhaustive list of all possible uses
of the products, nor is it intended to imply that the uses listed may be suitable for the products:
• Outdoor use, uses involving potential chemical contamination or electrical interference, or conditions or uses not described in this document.
• Nuclear energy control systems, combustion systems, railroad systems, aviation systems, medical equipment, amusement machines, vehicles, safety
equipment, and installations subject to separate industry or government regulations.
• Systems, machines, and equipment that could present a risk to life or property.
Please know and observe all prohibitions of use applicable to the products.
NEVER USE THE PRODUCTS FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY WITHOUT ENSURING THAT THE SYSTEM
AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT THE OMRON PRODUCT IS PROPERLY RATED AND INSTALLED FOR
THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM.
PERFORMANCE DATA
Performance data given in this document is provided as a guide for the user in determining suitability and does not constitute a warranty. It may represent the
result of OMRON’s test conditions, and the users must correlate it to actual application requirements. Actual performance is subject to the OMRON Warranty
and Limitations of Liability.
CHANGE IN SPECIFICATIONS
Product specifications and accessories may be changed at any time based on improvements and other reasons.
It is our practice to change model numbers when published ratings or features are changed, or when significant construction changes are made. However,
some specifications of the product may be changed without any notice. When in doubt, special model numbers may be assigned to fix or establish key specifications for your application on your request. Please consult with your OMRON representative at any time to confirm actual specifications of purchased
products.
DIMENSIONS AND WEIGHTS
Dimensions and weights are nominal and are not to be used for manufacturing purposes, even when tolerances are shown.
ERRORS AND OMISSIONS
The information in this document has been carefully checked and is believed to be accurate; however, no responsibility is assumed for clerical, typographical,
or proofreading errors, or omissions.
PROGRAMMABLE PRODUCTS
OMRON shall not be responsible for the user’s programming of a programmable product, or any consequence thereof.
COPYRIGHT AND COPY PERMISSION
This document shall not be copied for sales or promotions without permission. This document is protected by copyright and is intended solely for use in conjunction with the product. Please notify us before copying or reproducing this document in any manner, for any other purpose. If copying or transmitting this
document to another, please copy or transmit it in its entirety.
RFID System
User's Manual
Introduction
Introduction
Safety Precautions
Alert Symbols for Safe Use
The following symbols are used in this manual to indicate precautions that must be observed to ensure safe
use of the V680-HS51, V680-HS52, V680-HS63, V680-HS65, V680-H01-V2, V680-HA63A, V680D1KP52MT, V680-D1KP66T, V680-D1KP66MT, V680-D1KP66T-SP, and V680-D1KP58HT. The precautions
provided here contain important safety information. Be sure to observe these precautions.
The following signal words are used in this manual.
WARNING
Indicates a potentially hazardous situation which, if not avoided, will result in minor or moderate injury, or may result in serious injury or death. Additionally, there may be significant
property damage.
Meanings of Alert Symbols
Indicates general prohibitions for which there is no specific symbol.
Warning
WARNING
These Products are not designed to be used either directly or indirectly in applications that detect human
presence for the purpose of maintaining safety. Do not use these Products as a sensing means for protecting human lives.
Regulations and Standards
The Products conform to the following overseas regulations and standards.
1.The United States
Amplifier
Antenna
This product complies with Part 15 Subpart C of the FCC Rules.
FCC ID: E4E6CYSIDV6800406
V680-HA63A
This product complies with Part 15 Subpart C of the FCC Rules.
FCC ID: E4E6CYSIDV6800308
---
V680-HS51
V680-HS52
V680-HS63
V680-HS65
V680-H01-V2
FCC NOTICE
This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions:
(1) This device may not cause harmful interference.
(2) This device must accept any interference received, including interference that may cause undesired operation.
FCC WARNING
Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment.
Do not remove the ferrite core (TDK Type ZCAT1730-0730A:V680-HS52/-HS63/-HS65, TDK Type ZCAT15250430AP:V680-HS51, TDK Type ZCAT2035-0930:V680-H01-V2) installed on the cables to suppress RF interference.
RFID System
User's Manual
Introduction
Introduction
2. Europe
Amplifier
(Radio and Telecommunication Terminal Equipment Directive 1999/5/EC)
V680-HA63A
Radio:
EMC:
EN 300 330-2
EN 301 489-1
EN 301 489-3
Safety: EN 61010
---
Antenna
V680-HS51
V680-HS52
V680-HS63
V680-HS65
V680-H01-V2
English
Hereby, Omron, declares that the RFID System, V680-HS51 Series, V680-HS52 Series, V680-HS63 Series, V680-HS65 Series, V680-H01-V2 Series and
V680-HA63A Series are in compliance with the essential requirements and other relevant provisions of Directive 1999/5/EC.
Finnish
Omron vakuuttaa täten että RFID Säännös, V680-HS51 Series, V680-HS52 Series, V680-HS63 Series, V680-HS65 Series, V680-H01-V2 Series, V680HA63A Series tyyppinen laite on direktiivin 1999/5/EY oleellisten vaatimusten ja sitä koskevien direktiivin muiden ehtojen mukainen.
Dutch
Hierbij verklaart Omron dat het toestel de RFID Systeem, V680-HS51 ´Serie, V680-HS52 ´Serie, V680-HS63 ´Serie, V680-HS65 ´Serie, V680-H01-V2
´Serie, V680-HA63A ´Serie in overeenstemming is met de essentiële eisen en de andere relevante bepalingen van richtlijh 1999/5/EG.
French
Par la présente Omron déclare que la RFID Système, V680-HS51 Série, V680-HS52 Série, V680-HS63 Série, V680-HS65 Série, V680-H01-V2 Série,
V680-HA63A Série sont conforme aux exigences essentielles et aux autres dispositions pertinentes de la directive 1999/5/CE.
Swedish
Härmed intygar Omron att den RFID System, V680-HS51 Serie, V680-HS52 Serie, V680-HS63 Serie, V680-HS65 Serie, V680-H01-V2 Serie, V680HA63A Serie stär l överensstämmelse med de väsentliga egenskapskrav och övriga relevanta bestämmelser som framgår av direktiv 1999/5/EG.
Danish
Undertegnede Omron erklærer herved, at følgende den RFID System, V680-HS51 Serie, V680-HS52 Serie, V680-HS63 Serie, V680-H01-V2 Serie,
V680-HS65 Serie, 680-HA63A Serie overholder de væsentlige krav og øvrige relevante krav i direktiv 1999/5/EF.
German
Hiermit erklärt Omron, die RFID System, V680-HS51 Serie, V680-HS52 Serie, V680-HS63 Serie, V680-HS65 Serie, V680-H01-V2 Serie, V680-HA63A
Serie in Übereinstimmung mit den grundlegenden Anforderungen und den anderen relevanten Vorschriften der Richtlinie 1999/5/EG befindet. (BMWi)
Greek
ME THN ΠAPOYSA Omron ΔHΛONEI RFID O’YO’ΓΗΜΑ, V680-HS51 O’EIPA, V680-HS52 O’EIPA, V680-HS63 O’EIPA, V680-HS65 O’EIPA, V680H01-V2 O’EIPA, V680-HA63A O’EIPA SYMMOPF ONETAI ΠPOS TIS OYSIOΔEIS AΠAITHSEIS KAI TIS ΛOIΠES SXETIKES ΔIATAΞEIS THS
OΔHΓIAS 1999/5/EK.
Italian
Con la presente Omron dichiara che la RFID Sistema, V680-HS51Serie, V680-HS52Serie, V680-HS63 Serie,V680-HS65 Serie,V680-H01-V2 Serie,
V680-HA63A Serie sono conforme ai requisiti essenziali ed alle altre disposizioni pertinenti stabilite dalla direttiva 1999/5/CE.
Spanish
Por medio de la presente Omron declara que el RFID Sistema, V680-HS51 Serie, V680-HS52 Serie, V680-HS63 Serie, V680-HS65 Serie, V680-H01-V2
Serie, V680-HA63A Serie esta conforme a los requisitos esenciales y cualesquiera otras disposiciones aplicables o exigibles de la Directiva 1999/5/CE.
Portuguese
Omron declara que a RFID Sistema, V680-HS51 Série, V680-HS52 Série, V680-HS63 Série, V680-HS65 Série, V680-H01-V2 Série, V680-HA63A
Série ser conforme com os tequisitos essenciais e outras disposições da Directiva 1999/5/CE.
Romanian
Prin prezenta, Omron declar c acest V680-HS51, V680-HS52, V680-HS63, V680-HS65, V680-H01-V2, V680-HA63A este conform cu cerin ele principale çi cu celelalte prevederi relevanate ale Directivei 1999/5/EC.
3. Japan
Amplifier
Antenna
Equipment using high frequencies: Inductive Reading/Writing Communications Equipment
V680-HA63A V680-HS51
Conforming standards: Inductive Reading/Writing Communications Equipment; Standard: ARIB STD-T82
V680-HS52
EC-06019
V680-HS63
V680-HS65
Equipment using high frequencies: Inductive Reading/Writing Communications Equipment
Conforming standards: Inductive Reading/Writing Communications Equipment; Standard: ARIB STD-T82
EC-@@@@@
---
V680-H01-V2
4. Canada
Amplifier
Antenna
IC ID:850J-V68HA63A
V680-HA63A
V680-HS51
V680-HS52
V680-HS63
V680-HS65
IC ID:850J-V6800308
---
V680-H01-V2
This device complies with RSS-Gen of IC Rules.
Operation is subject to the following two conditions:(1) this device may not cause harmful interference, and (2) this
device must accept any interference received, including interference that may cause undesired operation.
RFID System
User's Manual
Introduction
Introduction
5. China
Amplifier
Antenna
CMII ID:2008DJ0884
V680-HA63A
V680-HS51
CMII ID:2007DJ0577
V680-HA63A
V680-HS52-R
CMII ID:2007DJ0575
V680-HA63A
V680-HS52-W
CMII ID:2007DJ0571
V680-HA63A
V680-HS63-R
CMII ID:2007DJ0573
V680-HA63A
V680-HS63-W
CMII ID:2008DJ0141
V680-HA63A
V680-HS65-R
CMII ID:2008DJ0142
V680-HA63A
V680-HS65-W
6. Korea
Amplifier
OMR-V680-HA63A
V680-HA63A
Antenna
V680-HS51
V680-HS52
V680-HS63
V680-HS65
7. Taiwan
Amplifier
CCAB07LP1220T4
V680-HA63A
Antenna
V680-HS51
V680-HS52
V680-HS63
V680-HS65
RFID System
User's Manual
Introduction
Introduction
8. Hong Kong
Amplifier
LP407043
V680-HA63A
Antenna
V680-HS52
V680-HS63
9. Singapore
Amplifier
S0294-07
V680-HA63A
Antenna
V680-HS51
V680-HS52
V680-HS63
V680-HS65
10.Malaysia
Amplifier
A011578
V680-HA63A
Antenna
V680-HS51
V680-HS52
V680-HS63
V680-HS65
If the product is used in Malaysia, a label must be attached on-site to the side of the V680-HA63A.
Please consult your OMRON sales representative for details.
11.Philippine
Amplifier
ESD-0702971C
V680-HA63A
Antenna
V680-HS51
V680-HS52
V680-HS63
V680-HS65
12.Mexico
Amplifier
COFETEL:RLVOMV607-622-A2
V680-HA63A
Antenna
V680-HS51
V680-HS52
V680-HS63
V680-HS65
Este equipo opera a titulo secundario, consecuentemente, debe aceptar interferencias perjudiciales incluyendo
equipos de la misma clase y puede no causar interferencias a sistemas operando a titulo primario.
13.Thailand
The certification is unnecessary, so the product can be used.
Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment.
Do not remove the ferrite core (TDK Type ZCAT1730-0730A:V680-HS52/-HS63/-HS65, TDK Type ZCAT15250430AP:V680-HS51, TDK Type ZCAT2035-0930:V680-H01-V2) installed on the cables to suppress RF interference.
RFID System
User's Manual
Introduction
Introduction
Precautions for Safe Use
Be sure to observe the following precautions to ensure safe use of the Products.
1. Do not use the Products in environments with flammable, explosive, or corrosive gasses.
2. Do not attempt to disassemble, repair, or modify any Product.
3. Tighten mounting screws securely.
4. Because a cable has a locking mechanism, make sure that it has been locked before using the cable.
5. Do not allow water or pieces of wire to enter from openings in the case. Doing so may cause fire or
electric shock.
6. Turn OFF the Controller power supply before mounting or removing an Antenna or Amplifier.
7. Turn OFF the power supply to the Controller before changing settings.
Attach a Setting switch protection Cover after setting Switch.
8. If an error is detected in any Product, immediately stop operation and turn OFF the power supply. Consult
with an OMRON representative.
9. Dispose of the Products as industrial waste.
10. Observe all warnings and precautions given in the body of this manual.
11. Do not touch the product immediately after usage at high temperatures. Doing so may occasionally result
in burning.
12. Do not open the back cover of the V680-H01-V2 antenna.
13. Do not install the Products near equipment that generates a large amount of heat, such as a heater,
transformer, or high-capacity resistor.
RFID System
User's Manual
Introduction
Introduction
Precautions for Correct Use
Always observe the following precautions to prevent operation failures, malfunctions, and adverse effects on
performance and equipment.
1. Installation Environment
Do not use the Products in the following locations.
• Locations exposed to direct sunlight
• Locations exposed to corrosive gases, dust, metallic powder, or salts
• Locations not within the specified operating temperature range
• Locations subject to rapid changes in temperature or condensation
• Locations not within the specified humidity range
• Locations subject to direct vibration or shock outside the specified ranges
• Locations subject to spray of water, oil, or chemicals
2. Installation
The Products communicate with Tags using the 13.56-MHz frequency band. Some motors, inverters,
and switching power supplies generate noise that can affect communications with the Tags and cause
errors. If such devices are located near the Tags, always test operation in advance to confirm whether
the system will be affected.
• Observe the following precautions to minimize the effects of normal noise.
(1) Ground all metal objects in the vicinity of the Products to 100 Ω or less.
(2) Do not use the Products near high-voltage or high-current lines.
• Do not use non-waterproof Products in an environment where mist is present.
• Do not expose the Products to chemicals that adversely affect the Product materials.
• When mounting the Products, tighten the screws to the following torques.
V680-HS51: 6 N⋅m
V680-HS52: 40 N⋅m
V680-HS63: 1.2 N⋅m
V680-HS65: 1.2 N⋅m
V680-H01-V2: 1.2 N⋅m
• Do not pull the Antenna connector over the power of 30 N.
The Antenna connector may be broken.
• Transmission will not be possible if the front and back panels are mistakenly reversed and the Unit is
mounted to a metallic surface.
V680-D1KP66MT
• The transmission distance will be reduced when the Unit is not mounted to a metallic surface.
V680-D1KP66MT
• If multiple Antennas are mounted near each other, communications performance may decrease due
to mutual interference. Refer to Installing Antennas on page 56 and check to make sure there is no
mutual interference.
• Depending on the operating environment, the case surface may become fogged, but basic performance will not be affected.
RFID System
User's Manual
Introduction
Introduction
3. Storage
Do not store the Products in the following locations.
• Locations exposed to direct sunlight
• Locations exposed to corrosive gases, dust, metallic powder, or salts
• Locations not within the specified storage temperature range
• Locations subject to rapid changes in temperature or condensation
• Locations not within the specified storage humidity range
• Locations subject to direct vibration or shock outside the specified ranges
• Locations subject to spray of water, oil, or chemicals
4. Cleaning
• Do not clean the Products with paint thinner or the equivalent. Paint thinner, benzene, acetone, and
kerosene or the equivalent will dissolve the resin materials and case coating.
5. Combination of the Amplifier
• Use the V680-D1KP52MT, V680-D1KP66T, V680-D1KP66MT, and V680-D1KP66T-SP ID Tags in
combination with only the V680-HA63A Amplifier. Do not use these ID Tags together with the V680HA63B Amplifier.
RFID System
User's Manual
Introduction
Introduction
Meanings of Symbols
10
Meanings of Symbols
Indicates particularly important points related to a function, including precautions and application advice.
Indicates page numbers containing relevant information.
RFID System
User's Manual
Introduction
Introduction
Table of Contents
Safety Precautions
Regulations and Standards
Precautions for Safe Use
Precautions for Correct Use
Meanings of Symbols
10
Table of Contents
11
Section 1 Product Overview
13
Features
14
Product Configuration
15
Section 2 Specifications and Performance
17
Antennas with Separate Amplifier
18
Antennas with Built-in Amplifier
25
Amplifier
30
Tags
33
Section 3 Communications Specifications
43
Communications Distances
44
Communication Time (Reference)
53
Section 4 Installation
55
Installing Antennas
56
Mounting Amplifiers
65
Installing Tags
67
Section 5 Chemical Resistance
79
Chemical Resistance of the Antennas
80
Chemical Resistance of Tags
81
Degree of Protection
85
Revision History
88
RFID System
User's Manual
11
Introduction
Introduction
12
MEMO
RFID System
User's Manual
Section 1
Section 1
Product Overview
14
Product Configuration
15
RFID System
User's Manual
Product Overview
Features
13
Section 1
Product Overview
Features
The V680-series RFID System actively supports many different types of system, such as distributed-control
Section 1 Features
systems and many-product, small-lot production systems, with non-contact data communications using
electromagnetic induction.
„ Non-contact Data Communications
The V680 Series uses electromagnetic induction to enable non-contact, bi-directional data communications between Antennas and Tags.
„ EEPROM Memory
EEPROM (non-volatile memory) is used for Tag memory. No battery is required, so there is no need to
be concerned about battery service life.
„ CRC Used for Transmission Error Detection
A bi-directional 16-bit CRC (Cyclic Redundancy Check) has been added as the error detection method
for wire transmissions between ID Controllers and Antennas, and for wireless transmissions between
Antennas and Tags. This method maintains superior communications reliability even where problems
such as noise occur.
„ 1,000byte of Memory
Tags have 1,000byte of memory. In addition to the ID data required on-site, data such as model numbers and inspection information can be input.
„ Long Service Life of 100,000 Data Rewrites at Normal Temperatures
When the Tag is used at temperatures of up to 25°C, each block of EEPROM data can be rewritten up
to 100,000 times (in units of single block, 8-bytes).
„ Superior Environmental Resistance and High Reliability
Antennas and Tags now have greater environmental resistance and are not affected by vibration, oil, or
water.
14
RFID System
User's Manual
Section 1
Product Overview
Product Configuration
A V680-series RFID System consists of an ID Controller, one or more Amplifiers, one or two Antennas, and
Section 1 Product Configuration
Tags. Select the models suitable for the application.
„ Using Antennas with Separate Amplifiers
Programmable Controller
(SYSMAC CS/CJ Series)
Host device
Personal computer
RS-232C
RS-422
RS-485
CS1W-V680C11/12
V680-CA5D02-V
ID Controller
ID Sensor Units
V680-CA5D01-V
V68
0C1
RUN1
ERC
NOR
ERP
ERH
T/R
M/ER
V68
0C1
RUN2
ERC
HEA
D1
T/R
ERP
ERH
HEA
T/R D2
NOR
M/ER
CJ1W-V680C11/12
NOR
M/ER
TES
TES
ON
ON
HEA
D1
HEA
D1
DC2
INP 4V
UT
HEA
D2
Antennas with Separate
Amplifier
Amplifiers
V680-HA63A
V680-HS51
V680-HS63
V680-D1KP66T
V680-D1KP66MT
V680-HS65
V680-D1KP66T-SP
Tags
V680-D1KP52MT
V680-HS52
When embedding the V680-D1KP52MT into a metal surface, use the V680-HS51, V680-HS52 Antenna.
Transmission will not be possible if the V680-HS63 Antenna is used.
Use the V680-D1KP52MT, V680-D1KP66T, V680-D1KP66MT, and V680-D1KP66T-SP ID Tags in combination with only the
V680-HA63A Amplifier, Do not use these ID Tags together with the V680-HA63B Amplifier.
RFID System
User's Manual
15
Section 1
Product Overview
„ Using a V680-H01-V2 Antenna with Built-in Amplifier
Programmable Controller
(SYSMAC CS/CJ Series)
Section 1 Product Configuration
Host device
Personal computer
RS-232C
RS-422
RS-485
CS1W-V680C11
ID Controller
ID Sensor Units
V680-CA5D01-V
V700-A40-W
CJ1W-V680C11
V68
0C1
RUN1
ERC
NOR
ERP
ERH
T/R
M/ER
TES
ON
HEA
D1
Cable
* Always use the specified Cable to connect a
V680-H01-V2 Antenna. The V680-H01-V2
Antenna cannot be connected without using
the specified Cable.
Antennas with Built-in
Amplifier
V680-H01-V2
Tags
V680-D1KP58HT
16
RFID System
User's Manual
Section 2
Specifications and Performance
Section 2
18
Antennas with Built-in Amplifier
25
Amplifier
30
Tags
33
RFID System
User's Manual
Specifications and Performance
Antennas with Separate Amplifier
17
Section 2
Specifications and Performance
Antennas with Separate Amplifier
V680-HS51
„ General Specifications
Item
Model
V680-HS51
Section 2 Antennas with Separate Amplifier
Ambient operating
temperature
−10 to 60°C (with no icing)
Ambient storage
temperature
−25 to 75°C (with no icing)
Ambient operating
humidity
35% to 95% (with no condensation)
Insulation resistance
20 MΩ min. (at 500 VDC) between connector terminals and case
Dielectric strength
1,000 VAC, 50/60 Hz for 1 min between connector terminals and case
Degree of protection
IP67.(IEC60529)
In-house standard for antenna oil resistance (former JEM standard equivalent to IP67g)
Note: The connectors are not waterproof.
Dielectric strength
10 to 2,000 Hz, 1.5-mm double amplitude, acceleration: 150 m/s2, 10 sweeps in each of 3 axis directions (up/down, left/right, and forward/backward) for 15 minutes each
Shock resistance
1,000 m/s2, 3 times each in 6 directions (Total: 18 times)
Dimensions
M12 × 35 mm
Material
ABS resin, brass, and epoxy resin filler
Weight
Approx. 55 g
Cable length
Standard lengths of 2 m
„ Dimensions
• V680-HS51
12.5
(Unit : mm)
dia.
Toothed washer
26.2
12
M12 × 1
Connector
Ferrite core
Two lock nuts
Mounting Hole Dimensions
24
33
35
Coaxial cable, 2.9 dia.,
standard length: 2 m
(16.8 dia.)
50
25
(14.5 dia.)
17
9.6 dia.
21 dia
15
Insulation cover
18
RFID System
User's Manual
Case material
Brass
Communications
surface
ABS resin
Fill resin
Epoxy resin
Cable
PVC (black)
Section 2
Specifications and Performance
V680-HS52
„ General Specifications
Item
Model
V680-HS52-W
(Standard cable, waterproof connector)
V680-HS52-R
(Flexible cable, non-waterproof connector)
−10 to 60°C (with no icing)
Ambient storage
temperature
−25 to 75°C (with no icing)
Ambient operating
humidity
35% to 95% (with no condensation)
Insulation resistance
20 MΩ min. (at 500 VDC) between connector terminals and case
Dielectric strength
1,000 VAC, 50/60 Hz for 1 min between connector terminals and case
Degree of protection
IP67.(IEC60529)
In-house standard for antenna oil resistance
(former JEM standard equivalent to IP67g)
Note: The connector specifications are IP67 and
IP65.(IEC60529)
Dielectric strength
10 to 500 Hz, 1.5-mm double amplitude, acceleration: 100 m/s2, 10 sweeps in each of 3 axis directions
(up/down, left/right, and forward/backward) for 8 minutes each
Shock resistance
500 m/s2, 3 times each in 6 directions (Total: 18 times)
Dimensions
M22 × 65 mm
Material
ABS resin, brass, and epoxy resin filler
Weight
Approx. 850 g (with 12.5 m cable)
Cable length
Standard lengths of 2 and 12.5 m
Section 2 Antennas with Separate Amplifier
Ambient operating
temperature
IP67.(IEC60529)
In-house standard for antenna oil resistance
(former JEM standard equivalent to IP67g)
Note: The connectors are not waterproof.
„ Dimensions
• V680-HS52-W
22.5 dia.
Two toothed washers
Two lock nuts
Mounting Hole Dimensions
M22 × 1
Ferrite core
Operation indicator
37
16.5 dia.
30
Connector
14.5 dia.
19.8 dia.
35 dia.
30
47.6
50
57
65
16.5 dia.
Antenna
50
Insulation cover
Coaxial cable, 5.5 dia.,
standard length: 2 m
Case material
Brass
Communications
surface
ABS resin
Fill resin
Epoxy resin
Cable
PVC (gray)
RFID System
User's Manual
19
Section 2
Specifications and Performance
• V680-HS52-R
22.5 dia.
Two toothed washers
Two lock nuts
Mounting Hole Dimensions
(39.5)
35 dia.
30
14.5 dia.
16.5 dia.
30
47.6
50
57
65
RFID System
User's Manual
Insulation cover
Connector
16.5 dia.
Ferrite core
Operation indicator
Antenna
19.8 dia.
Section 2 Antennas with Separate Amplifier
20
M22 × 1
50
Coaxial cable, 5.3 dia.,
standard length: 2 m
Insulation cover
Case material
Brass
Communications
surface
ABS resin
Fill resin
Epoxy resin
Cable
PVC (black)
Section 2
Specifications and Performance
V680-HS63
„ General Specifications
Item
Model
V680-HS63-W
(Standard cable, waterproof connector)
−10 to 60°C (with no icing)
Ambient storage
temperature
−25 to 75°C (with no icing)
Ambient operating
humidity
35% to 95% (with no condensation)
Insulation resistance
20 MΩ min. (at 500 VDC) between cable terminals and case
Dielectric strength
1,000 VAC, 50/60Hz for 1 min between cable terminals and case
Degree of protection
IP67.(IEC60529)
In-house standard for antenna oil resistance
(former JEM standard equivalent to IP67g)
Note: The connector specifications are IP67 and
IP65.(IEC60529)
Vibration resistance
10 to 500 Hz, 1.5-mm double amplitude, acceleration: 100 m/s2, 10 sweeps in each of 3 axis directions
(up/down, left/right, and forward/backward) for 11 minutes each
Shock resistance
500 m/s2, 3 times each in 6 directions (Total: 18 times)
Dimensions
40 × 53 × 23 mm
Material
ABS resin case, epoxy resin filler
Weight
Approx. 850 g (with 12.5 m cable)
Cable length
Standard lengths of 2 and 12.5 m
Section 2 Antennas with Separate Amplifier
Ambient operating
temperature
V680-HS63-R
(Flexible cable, non-waterproof connector)
IP67.(IEC60529)
In-house standard for antenna oil resistance
(former JEM standard equivalent to IP67g)
Note: The connectors are not waterproof.
„ Dimensions
• V680-HS63-W
Antenna
(Unit: mm)
Ferrite core
30
53
16.5 dia.
14.5 dia.
27
16.5 dia.
40
28±0.1
37
Connector
50
Insulation cover
Coaxial cable, 5.5 dia.,
standard length: 2 m
11
23
Operation indicator
Note: Mounting Hole Dimensions
Two, M4 or 4.5 dia. holes
Coil center
Case material
ABS resin
Fill resin
Epoxy resin
Cable
PVC (gray)
RFID System
User's Manual
21
Section 2
Specifications and Performance
V680-HS63-R
Antenna
Ferrite core
30
53
RFID System
User's Manual
50
Coaxial cable, 5.3 dia.,
standard length: 2 m
Insulation cover
11
Operation indicator
Note: Mounting Hole Dimensions
Coil center
16.5 dia.
16.5 dia.
14.5 dia.
40
28±0.1
27
23
Section 2 Antennas with Separate Amplifier
22
(39.5)
(Unit: mm)
Connector
Two, M4 or 4.5 dia. holes
Case material
ABS resin
Fill resin
Epoxy resin
Cable
PVC (black)
Section 2
Specifications and Performance
V680-HS65
„ General Specifications
Item
Model
V680-HS65-W
(Standard cable, waterproof connector)
V680-HS65-R
(Flexible cable, non-waterproof connector)
−25 to 70°C (with no icing)
Ambient storage
temperature
−40 to 85°C (with no icing)
Ambient operating
humidity
35% to 95% (with no condensation)
Insulation resistance
20 MΩ min. (at 500 VDC) between connector terminals and case
Dielectric strength
1,000 VAC, 50/60 Hz for 1 min between connector terminals and case
Degree of protection
IP67 (IEC60529)
In-house standard for antenna oil resistance
(former JEM standard equivalent to IP67g)
Note: The connector specifications are IP67 and
IP65 (IEC 60529).
Dielectric strength
10 to 500 Hz, 1.5-mm double amplitude, acceleration: 100 m/s2, 10 sweeps in each of 3 axis directions
Section 2 Antennas with Separate Amplifier
Ambient operating
temperature
IP67 (IEC60529)
In-house standard for antenna oil resistance
(former JEM standard equivalent to IP67g)
Note: The connectors are not waterproof.
(up/down, left/right, and forward/backward) for 11 minutes each
Shock resistance
500 m/s2, 3 times each in 6 directions (Total: 18 times)
Dimensions
100 × 100 × 30 mm
Material
ABS resin case, epoxy resin filler
Weight
Approx. 1100 g (with 12.5 m cable)
Cable length
Standard lengths of 2 and 12.5 m
„ Dimensions
• V680-HS65-W
4-4.5 dia.
(Mounting holes)
50
Operation indicator
(Unit: mm)
100
90±0.2
Ferrite core
Connector
50
37
16.5 dia.
16.5 dia.
100
90±0.2
14.5 dia.
25
Bushing
30
10
50
10
20
30
14
Coaxial cable, 5.5 dia.,
standard length: 2 m
Insulation cover
11
Case material
ABS resin
Fill resin
Epoxy resin
Cable
PVC (gray)
RFID System
User's Manual
23
Section 2
Specifications and Performance
V680-HS65-R
4-4.5 dia.
(Mounting holes)
50
Operation indicator
(Unit: mm)
100
90±0.2
Ferrite core
50
Bushing
30
10
20
30
User's Manual
50
10
14
RFID System
16.5 dia.
14.5 dia.
16.5 dia.
100
90±0.2
Section 2 Antennas with Separate Amplifier
24
Connector
(39.5)
25
Coaxial cable, 5.3 dia.,
standard length: 2 m
Insulation cover
11
Case material
ABS resin
Fill resin
Epoxy resin
Cable
PVC (black)
Section 2
Specifications and Performance
Antennas with Built-in Amplifier
V680-H01-V2
„ General Specifications
Item
Model
V680-H01-V2
−10 to 55°C (with no icing)
Ambient storage
temperature
−35 to 65°C (with no icing)
Ambient operating
humidity
35% to 85% (with no condensation)
Insulation resistance
20 MΩ min. (at 100 VDC) between connector terminals and the rear plate
Dielectric strength
1,000 VAC, 50/60 Hz for 1 min between connector terminals and the rear plate
Degree of protection
IP63.(IEC60529); Mounting direction: Communications surface facing up
Dielectric strength
10 to 150 Hz, 0.35-mm single amplitude, acceleration: 50 m/s2, 10 sweeps in each of 3 axis directions
(up/down, left/right, and forward/backward) for 8 minutes each
Shock resistance
150 m/s2, 3 times each in 6 directions (Total: 18 times)
Cable length
0.5 m (use an extension cable to connect to the Controller up to 30.5 m)
LED indicators
RUN, COMM, NORM, ERR, CNT-TYPE, TAG-TYPE, Error Code, Level
Weight
Approx. 900 g
Section 2 Antennas with Built-in Amplifier
Ambient operating
temperature
„ Communications Specifications
Item
Model
V680-H01-V2
Communications method Electromagnetic induction
Operating frequency
13.56 MHz ± 7KHz
Modulation
ASK
RFID System
User's Manual
25
Section 2
Specifications and Performance
„ Dimensions
MOUNTING SCREW HOLES
(Unit : mm)
Connector
Vinyl Insulated Round Cord (5.8-dia.)
(41/0.16-dia.) 2 Cores (17/0.08-dia.) 8 Cores
Standard Length 0.5 m
142.5
235±0.2
Four, M4 or 4.5-dia. holes
Twelve, Operation Indicator
Four, 5-dia. holes
(Mounting Holes)
Communications sufrace
14
64.8
20-dia.
185
(25-dia.)
200
Ferrite Core
65
Section 2 Antennas with Built-in Amplifier
185±0.2
Senter of Coil
50
Four, Mounting bracket
Setting switch protection Cover
30 38
142.5
235
7.5
(17)
+50
500
13.5
40
(1)
250
26
RFID System
User's Manual
Case material
PC/ASA resin
Rear Panel
Aluminum
Cable
PVC
(45)
Section 2
Specifications and Performance
„ Operation Indicator
name
Color
Meaning
RUN
Green Lit when the power is ON.
COMM
Yellow Lit when a command is being sent.
NORM
Green Lit when communications with a Tag are normal in Normal Communications Mode.
ERR
Red
Section 2 Antennas with Built-in Amplifier
Lit when an error occurs in communications with a Tag in Normal Communications
Mode.
CNT-TYPE Yellow Lit when in V680-CA@D Controller connection mode (SW1-1 setting: ON).
TAG-TYPE Yellow For expansion (not used): Always OFF.
LV6/7D
Yellow Maintenance Mode: Lit at distance or speed level 6.
Normal Communications Mode: Lit when a write protection error occurs.
LV5/7A
Yellow Maintenance Mode: Lit at distance or speed level 5 or higher.
Normal Communications Mode: Lit when an address error occurs.
LV4/76
Yellow Maintenance Mode: Lit at distance or speed level 4 or higher.
Normal Communications Mode: Lit when a Tag memory error occurs.
LV3/72
Yellow Maintenance Mode: Lit at distance or speed level 3 or higher.
Normal Communications Mode: Lit when a no Tag error occurs.
LV2/71
Yellow Maintenance Mode: Lit at distance or speed level 2 or higher.
Normal Communications Mode: Lit when a verification error occurs.
LV1/70
Yellow Maintenance Mode: Lit at distance or speed level 1 or higher.
Normal Communications Mode: Lit when a Tag communications error occurs.
The distance level will vary greatly depending on the surrounding environment. The setting position will serve as a
guide, but use RUN mode to conduct a sufficient number of tests in the actual operating environment.
Values of distance level 4 or above may not be displayed, but this will not affect the RUN mode performance and does
not indicate a malfunction.
Differences between the V680-H01 and the V680-H01-V2
As shown in the following table, the V680-H01-V2 provides additional indicators.
Turn ON SW1-1(Antenna) when using the V680-CA1D/CA2D.
display functions
RUN (POWER/COMM)
V680-H01-V2
V680-H01
SW1-1: OFF
SW1-1: ON
no switch
OK
OK
OK
COMM (POWER/COMM)
OK
OK
OK
NORM
OK
NO
NO
ERR
OK
NO
NO
CNT-TYPE
OK
OK
NO
TAG-TYPE
---
---
---
LV6/7D
OK
NO
NO
LV5/7A
OK
NO
NO
LV4/76
OK
NO
NO
LV3/72
OK
NO
NO
LV2/71
OK
NO
NO
LV1/70
OK
NO
NO
RFID System
User's Manual
27
Section 2
Specifications and Performance
„ Setting Switch
Section 2 Antennas with Built-in Amplifier
Setting switch protection cover
Note: Please attach a setting switch protection cover after setting switch.
Setting
Function
Default setting
SW1-1
Controller selection
OFF:V680-CA5D01-V@, CS1W-V680C11, or CJ1W-V680C11
ON: V680-CA1D/-CA2D
OFF
SW1-2
Reserved by System (Always set this Switch to OFF.)
---
SW1-3
Reserved by System (Always set this Switch to OFF.)
---
SW1-4
Reserved by System (Always set this Switch to OFF.)
---
Set SW1-1 on the V680-H01-V2 Antenna and the Controller as shown in the following table.
Antenna setting
V680-H01-V2
Controller setting
V680-CA5D01-V@
CS1W-V680C11
CJ1W-V680C11
V680-CA1D
V680-CA2D
SW1-1: OFF
SW4-8: OFF
DM20000 + 100 × m+3=0000
SW1-1: ON
SW4-8: ON See Note.
DM20000 + 100 × m+3=0001 See Note.
See Note.
: Cannot be used.
: Can be used.(Controller setting not required.)
Note: The high-speed mode cannot be used by the controller's setting.
Differences between the V680-H01 and the V680-H01-V2
As shown in the following table, the V680-H01-V2 supports additional maintenance functions.
Turn ON SW1-1(Antenna) when using the V680-CA1D/CA2D.
display functions
28
RFID System
User's Manual
V680-H01-V2
V680-H01
SW1-1: OFF
SW1-1: ON
no switch
Communication Test Mode
OK
OK
OK
Noise Level Measurement
Mode
OK
NO
NO
Distance Level Measurement
Mode
OK
NO
NO
Speed Level Measurement
Mode
OK
NO
NO
Communications Success
Rate Measurement Mode
OK
NO
NO
Section 2
Specifications and Performance
Cables (V680-H01-V2 exclusive use)
„ Specifications
Item
Model
V700-A40-W
Number of conductors 10
Insulation resistance
5 MΩ min. (at 500 VDC) between terminals and sheath
Dielectric strength
500 VAC, 1 min
Section 2 Antennas with Built-in Amplifier
„ Dimensions
Item
Model
Length (L1)
Weight
L1
V700-A40-W 2M
V700-A40-W 5M
V700-A40-W 10M
V700-A40-W 20M
V700-A40-W 30M
Approx.2m
Approx. 5 m
Approx.10m
Approx. 20 m
Approx. 30 m
Approx. 150 g
Approx.360 g
Approx. 700 g
Approx.1,350 g
Approx.2,000 g
2,000
5,000
10,000
20,000
30,000
(Unit: mm)
49
L1±100
20 dia.
15 dia.
41.8
Connector (Controller end))
Connector (Antenna end))
Connection label
Vinyl Insulated Round Cord
Cable
6 dia.
PVC
RFID System
User's Manual
29
Section 2
Specifications and Performance
Amplifier
V680-HA63A
„ General Specifications
Item
Model
V680-HA63A
Section 2 Amplifier
Ambient operating
temperature
−10 to 55°C (with no icing)
Ambient storage
temperature
−25 to 65°C (with no icing)
Ambient operating
humidity
35% to 85% (with no condensation)
Insulation resistance
20 MΩ min. (at 500 VDC) between cable terminals and case
Dielectric strength
1,000 VAC, 50/60 Hz for 1 minute between cable terminals and case.
Degree of protection
IP67, IP65 (IEC 60529)
Note: Not including connector at Controller end.
(When V680-HS52-W, V680-HS63-W, and V680-HS65-W
is connected)
Dielectric strength
10 to 500 Hz, 1.5-mm double amplitude, acceleration:100 m/s2, 10 sweeps in each of 3 axis directions
(up/down, left/right, and forward/backward) for 11 minutes each
Shock resistance
500 m/s2, 3 times each in 6 directions (Total: 18 times)
Dimensions
25 × 40 × 65 mm (Not including protrusions.)
Materials
PC
Weight
Approx. 650 g (with 10 m cable)
Cable length
Standard lengths of 5 and 10 m
IP40 (IEC 60529)
(When V680-HS51, V680-HS52-R, V680HS63-R, and V680-HS65-R is connected)
Note: The maximum total cable extension is 50 m (including the Amplifier cable). A maximum of two extension cables can be
connected.
„ Dimensions
65
18
30
25
40
25
9.5 dia.
Connector
RFID System
User's Manual
36
35.6
3.5
Connector
15
25
51
15 dia.
13.7
12.8 dia.
Operation indicator
Round, vinyl-insulated cable (5.8 dia.), standard length: 5 m,
(41/0.16 dia) 2 conductors, (17/0.08 dia.) 8 conductors
Case material
PC resin
Cable
PVC
Section 2
Specifications and Performance
Nomenclature
Antenna with Separate Amplifier connection port
Operation indicators
Section 2 Amplifier
RUN
COMM
NORM
ERR
LV6/7D
LV5/7A
LV4/76
LV3/72
LV2/71
LV1/70
Controller connector
„ Antenna Connection Port
The Antenna connection port is connected a V680-series Antenna.
„ Controller Connector
The Controller connector is connected to Antenna connection port on the Controller.
„ Operation Indicators (LEDs)
Name
Color
RUN
Green Lit when the power is ON.
COMM
NORM
Yellow
Meaning
Lit when a command is being sent.
Green Lit when communications with a Tag are normal in Normal Communications Mode.
ERR
Red
Lit when an error occurs in communications with a Tag in Normal Communications Mode.
LV6/7D
Yellow
Maintenance Mode: Lit at distance or speed level 6.
Normal Communications Mode: Lit when a write protection error occurs.
LV5/7A
Yellow
Maintenance Mode: Lit at distance or speed level 5 or higher.
Normal Communications Mode: Lit when an address error occurs.
LV4/76
Yellow
Maintenance Mode: Lit at distance or speed level 4 or higher.
Normal Communications Mode: Lit when a Tag memory error occurs.
LV3/72
Yellow
Maintenance Mode: Lit at distance or speed level 3 or higher.
Normal Communications Mode: Lit when a no Tag error occurs.
LV2/71
Yellow
Maintenance Mode: Lit at distance or speed level 2 or higher.
Normal Communications Mode: Lit when a verification error occurs.
LV1/70
Yellow
Maintenance Mode: Lit at distance or speed level 1 or higher.
Normal Communications Mode: Lit when a Tag communications error occurs.
The distance level will vary greatly depending on the surrounding environment. The setting position will serve as a
guide, but use RUN mode to conduct a sufficient number of tests in the actual operating environment.
Values of distance level 4 or above may not be displayed, but this will not affect the RUN mode performance and does
not indicate a malfunction.
RFID System
User's Manual
31
Section 2
Specifications and Performance
Cables (V680-HA63 exclusive use)
„ Specifications
Item
Model
V700-A43/V700-A44
Number of conductors 10
Insulation resistance
5 MΩ min. (at 500 VDC) between terminals and sheath
Dielectric strength
500 VAC, 1 min
Item
Model
Length (L1)
Weight
V700-A43
V700-A44
Approx.10m
Approx. 20 m
Approx. 700 g
Approx.1,350 g
L1±100
49
6 dia.
15 dia.
51
15.5 dia.
Section 2 Amplifier
„ Dimensions
Connector (Amplifier end)
Connector (Controller end))
Connection label
(Unit: mm)
Cable
32
RFID System
User's Manual
PVC
Section 2
Specifications and Performance
Tags
Specifications and Dimensions
„ V680-D1KP52MT
• General Specifications
Model
V680-D1KP52MT
1,000 bytes (user area)
Memory type
EEPROM
Data backup time
10 years after writing (85°C or less), 0.5 years after writing (85°C to 125°C)
Total data backup time at high temperatures exceeding 125°C is 10 houres (See note.)
Memory longevity
100,000 times per block (25°C)
Ambient operating
temperature
−25 to 85°C (with no icing)
Ambient storage
temperature
−40 to 125°C (with no icing)
Ambient operating
humidity
35% to 95%
Degree of protection
IP68 (IEC 60529)
In-house standard for antenna oil resistance (former JEM standard equivalent to IP67g)
Vibration resistance
10 to 2,000 Hz, 1.5-mm double amplitude, acceleration: 150 m/s2, 10 sweeps each in X, Y, and Z
directions for 15 minutes each
Shock resistance
500 m/s2, 3 times each in X, Y, and Z directions (Total: 18 times)
Dimensions
8 dia. × 5 mm
Materials
Case: PPS resin, Fill resin: Epoxy resin
Weight
Approx. 0.5 g
Metal countermeasures
Yes
Section 2 Tags
Item
Memory capacity
Note: After string data at high temperatures, rewrite the data even if changes are not required, In this manual, high
temperatures are those exceeding 125°C up to 180°C.
• Dimensions
R0.2
8 −0.1 dia.
5 −0.1
(Unit : mm)
Case material
PPS resin
Fill resin
Epoxy resin
When embedding the V680-D1KP52MT into a metal surface, use the V680-HS51, V680-HS52 Antenna.
Transmission will not be possible if the V680-HS63 Antenna is used.
The side with the markings is the communications surface. Mount the Tag with this side facing the Antenna.
The ID code is written in the memory of the Tag and may be affected by data retention characteristics at high temperatures. Take suitable precautions when using the READ ID command for Tags operating at high temperatures.
RFID System
User's Manual
33
Section 2
Specifications and Performance
„ V680-D1KP66T/66MT
• General Specifications
Item
Model
V680-D1KP66T
V680-D1KP66MT
Section 2 Tags
Memory capacity
1,000 bytes (user area)
Memory type
EEPROM
Data backup time
10 years after writing (85°C or less), 0.5 years after writing (85°C to 125°C)
Total data backup time at high temperatures exceeding 125°C is 10 houres (See note.)
Memory longevity
100,000 times per block (25°C)
Ambient operating
temperature
−25 to 85°C (with no icing)
Ambient storage
temperature
−40 to 125°C (with no icing)
Ambient operating
humidity
35% to 95%
Degree of protection
IP68 (IEC 60529)
In-house standard for antenna oil resistance (former JEM standard equivalent to IP67g)
Vibration resistance
10 to 2,000 Hz, 1.5-mm double amplitude, acceleration: 150 m/s2,10 sweeps each in X, Y, and Z
directions for 15 minutes each
Shock resistance
500 m/s2, 3 times each in X, Y, and Z directions (Total: 18 times)
Dimensions
34 × 34 × 3.5 mm
Materials
Case: PPS resin
Weight
Approx. 6 g
Approx. 7.5 g
Metal countermeasures
None
Yes
Note: After string data at high temperatures, rewrite the data even if changes are not required, In this manual, high
temperatures are those exceeding 125°C up to 180°C.
The V680-D1KP66MT is designed to be mounted directly to metal. The V680-D1KP66T and V680D1KP66MT markings are shown in the following diagrams.
V680-D1KP66MT
V680-D1KP66MT
V680-D1KP66T
V680-D1KP66T
XXXXXX
XXXXXX
MADE IN JAPAN
MADE IN JAPAN
The side with the markings is the communications surface. Mount the Tag with this side facing the Antenna.
The ID code is written in the memory of the Tag and may be affected by data retention characteristics at high temperatures. Take suitable precautions when using the READ ID command for Tags operating at high temperatures.
34
RFID System
User's Manual
Section 2
Specifications and Performance
• Dimensions
V680-D1KP66T/66MT
Four, R4
34
Four, R3
25+0.2
32
Mounting Hole Dimensions
25+0.2
Two, M3
25+0.2
Section 2 Tags
Two, 3.5 dia.
Two, 6 dia.
32
25+0.2
3.5+0.1
34
Case material
PPS resin
V600-A86 Attachment
Four, R5.5
25+0.2
Two, 4 dia.
Two, M3
37
34
15
25+0.2
16
25+0.2
25+0.2
15
34
3.5
37
10
Case material
PPS resin
Tag Heat Resistivity
• Storing Tags under high temperatures will adversely affect the performance of the internal parts and
the service life of the Tags.
• An LTPD of 10% was determined during the evaluation for Tags that reached the end of their life after
testing under the following test conditions.
Heat cycle
−10°C/+150°C, 30 minutes each for 1,000 cycles
−100°C/+180°C,30 minutes each for 200 cycles
High temperatures
+150°C, 1,000 hours
+180°C, 200 hours
LTPD: Lot tolerance percent defective
The lower limit of the malfunction rate for lots to be considered unacceptable during reliability testing.
RFID System
User's Manual
35
Section 2
Specifications and Performance
„ V680-D1KP66T-SP
• General Specifications
Item
Model
V680-D1KP66T-SP
Memory capacity
1,000 bytes (user area)
Memory type
EEPROM
Data backup time
10 years after writing (85°C or less)
Section 2 Tags
Memory longevity
100,000 times per block (25°C)
Ambient operating
temperature when
communicating
−25 to 70°C (with no icing)
Ambient operating
temperature when not
communicating
−40 to110°C (with no icing)
Ambient storage
temperature
−40 to 110°C (with no icing)
Ambient operating
humidity
35% to 95%
Degree of protection
IP67
Vibration resistance
10 to 2,000 Hz, 1.5-mm double amplitude, acceleration: 150 m/s2,10 sweeps each in X, Y, and Z
directions for 15 minutes each
Shock resistance
500 m/s2, 3 times each in X, Y, and Z directions (Total: 18 times)
Dimensions
95 × 36.5 × 6.5 mm (excluding protruding parts)
Materials
External coatiog: Fluororesin (PFA)
Tag body: PPS resin
Weight
Approx. 20 g
Mounting method
Two M5 screws
Metal countermeasures
None
• Dimensions
Four, R6
34
Two, 5.5 dia.
(Mounting hole)
(Unit: mm)
Mounting Hole Dimensions
Two, M5
36.5
34
80±0.2
1.3
6.5 2.5 max.
80±0.2
Case material PFA resin
95
The side with the markings is the communications surface. Mount the Tag with this side facing the Antenna.
36
RFID System
User's Manual
Section 2
Specifications and Performance
„ V680-D1KP58HT
• General Specifications
Item
Model
V680-D1KP58HT
1,000 bytes (user area)
Memory type
EEPROM
Data backup time
10 years after writing (85°C or less), 2 years after writing (85°C to 110°C)
Total data backup time at high temperatures exceeding 110°C is 10 houres (See note.)
Memory longevity
100,000 times per block (25°C)
Ambient operating
temperature
−10 to 85°C (with no icing)
Ambient storage
temperature
−40 to 110°C (with no icing)
Degree of protection
IP67 (IEC 60529)
Vibration resistance
10 to 2,000 Hz, 1.5-mm double amplitude, acceleration: 150 m/s2,10 sweeps each in X, Y, and Z
directions for 15 minutes each
Shock resistance
500 m/s2, 3 times each in X, Y, and Z directions (Total: 18 times)
Materials
Coatiog: PPS resin
Weight
Approx. 90 g
Section 2 Tags
Memory capacity
Note: After string data at high temperatures, rewrite the data even if changes are not required, In this manual, high
temperatures are those exceeding 110°C up to 200°C.
The maximum operating temperature during communication is 85°C. The temperature of the actual Tag must not be
higher than 85°C when the Tag enters the Antenna's communications area. When using a Tag after storage at high temperature, perform tests before use, and make sure that the temperature of the Tag does not exceed 85°C during operation.
RFID System
User's Manual
37
Section 2
Specifications and Performance
• Tag Heat Resistivity
• Storing Tags under high temperatures will adversely affect the performance of the internal parts and
the service life of the Tags.
• An LTPD of 10% was determined during the evaluation for Tags that reached the end of their life after
testing under the following test conditions
• Heat cycle: Room temperature/200ÅãC, 30 minutes each for 2,000 cycles.
Section 2 Tags
• Normal operation has been confirmed after performing the above tests, although minor cracks may
occur.
LTPD: Lot tolerance percent defective
The lower limit of the malfunction rate for lots to be considered unacceptable during reliability testing.
• Reference Data (Evaluation Test Results)
Heat Resistance Evaluation Results
Defective Operation
10%
9%
Room temp. / 180
Room temp. / 200
Room temp. / 220
Defective rate(%)
8%
, 30min each
, 30min each
, 30min each
7%
6%
5%
4%
3%
2%
1%
0%
500
1000
1500
2000
Number of cycles
38
RFID System
User's Manual
2500
3000
3500
4000
Section 2
Specifications and Performance
• Dimensions
V680-D1KP58HT
(Unit: mm)
10±0.2
60 dia.
5°
5°
80 dia
Section 2 Tags
14 dia
Case material PPS resin
Two, R2
The side with the markings is the communications surface. Mount the Tag with this side facing the Antenna.
V680-A80 (Attachment)
This Attachment is specifically designed to secure V680-D1KP58HT Tags to the workpiece.
Applicable Tag model: V680-D1KP58HT
17
(Unit: mm)
20 dia.
12 dia.
M12
3.2 dia.
M12
11.5
15
50
40
Mounting Hole Dimensions
110
Provided Parts
Nuts (M12):
Split pin (3.2 × 20 mm): 1
RFID System
User's Manual
39
Section 2
Specifications and Performance
Memory Map
Data
Address
Section 2 Tags
0000
0001
0002
0003
03E6
03E7
User area
1 byte
EEPROM is used as memory in the Tags.
The memory capacity available to the user is 1,000 bytes, including 0000H to 0003H (the Write Protection Setting Area).
The access to the memory is executed at every block.
1 block is 8 bytes (8 addresses).
40
RFID System
User's Manual
Section 2
Specifications and Performance
Write Protection Function
The write protection function prevents important data, such as product information, stored in memory in
a Tag from being inadvertently overwritten.
After important data has been written to memory, it can be write-protected using the following method.
The write protection function can be switched with SW4-7 (Write Protection Function Setting) of the V680-CA5D@@-V@
Controller or with word (Write Protection Function Setting) in the DM(m+2)CH Area words allocated to the C@1W-
Section 2 Tags
V680C@@ ID Sensor Unit.
„ Setting the Write Protection Function
Write protection is set in Tag addresses 0000H to 0003H.
The setting for the most significant bit of address 0000H specifies whether or not write protection is enabled.
Address
Bit
YES/
NO
0000H
Upper two digits of start address (00H to 7FH)
0001H
Lower two digits of start address (00H to FFH)
0002H
Upper two digits of end address (00H to FFH)
0003H
Lower two digits of end address (00H to FFH)
• Write-protect Bit (Most significant bit of address 0000H)
1: Write-protected (Yes)
0: Not write-protected (No)
• Write Protection Setting Area
Start address: 0000H to 7FFFH
End address: 0000H to FFFFH
„ Write Protection Setting Examples
• Settings to write-protect addresses 0008H through 03E7H:
Address
Bit
0000H
0001H
0003H
0002H
• Settings to not write-protect any addresses:
Address
0000H
0001H
0002H
0003H
Bit
The write protection function is a function of the V680-CA5D@@-V@ Controller and the C@1W-V680C@@ ID Sensor
Unit. It is not supported by reader/writer units from other manufacturers.
RFID System
User's Manual
41
Section 2
Specifications and Performance
MEMO
Section 2 Tags
42
RFID System
User's Manual

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.4
Linearized                      : No
Modify Date                     : 2008:10:15 15:23:51+09:00
Create Date                     : 2008:10:15 15:23:25+09:00
Title                           : Z262-E1-04
Author                          : OMRON
Creator                         : FrameMaker 7.0
Producer                        : Acrobat Distiller 8.1.0 (Windows)
Page Count                      : 44
Mod Date                        : 2008:10:15 15:23:51+09:00
Creation Date                   : 2008:10:15 15:23:25+09:00
Metadata Date                   : 2008:10:15 15:23:51+09:00
Has XFA                         : No
EXIF Metadata provided by EXIF.tools
FCC ID Filing: E4E6CYSIDV6800308