Onset Computer ONST6 HOBO RX Wireless Sensor Network User Manual RXW Temperatuer Sensor RXW TMB xxx Manual
Onset Computer Corporation HOBO RX Wireless Sensor Network RXW Temperatuer Sensor RXW TMB xxx Manual
Contents
- 1. User Manual_22241-2 RXW-SMx Manual.pdf
- 2. User Manual_22242-2 RXW-THC Manual.pdf
- 3. User Manual_22243-3 RXW-TMB Manual.pdf
- 4. User Manual_22244-2 RXW-RGx Manual.pdf
- 5. User Manual_22245-2 RXW-WCF Manual.pdf
- 6. User Manual_22246-2 RXW-LIA Manual.pdf
- 7. User Manual_22247-2 RXW-LIB Manual.pdf
- 8. User Manual_22248-2 RXMOD-RXW Manual.pdf
- 9. User Manual_22249-2 RXW-RPTR Manual.pdf
- 10. User Manual_22436-1 RXW-OBUS Manual.pdf
- 11. User Manual_22437-1 RXW-ANA Manual.pdf
- 12. User Manual_22438-1 RXW-SPER Manual.pdf
User Manual_22243-3 RXW-TMB Manual.pdf
HOBO® RX Wireless Sensor Network RXW Temperature Sensor (RXW-TMB-xxx) Manual This sensor measures temperature and is designed to work with the HOBO RX Wireless Sensor Network in which data is transmitted wirelessly from the sensor mote across the network to the RX3000 station and then uploaded to HOBOlink® web-based software. With HOBOlink, you can monitor sensor readings, view graphs, set up alarms, download data, and more. Specifications Sensor RXW Temperature Sensor Models: • RXW-TMB-900 (US) • RXW-TMB-868 (Europe) • RXW-TMB-922 (Australia/NZ) Items Included: • Cable ties Measurement Range -40° to 100°C (-40° to 212°F) Accuracy ±0.25°C from -40° to 0°C (±0.45°F from -40° to 32°F) ±0.20°C from 0° to 70°C (±0.36°F from 32° to 158°F) ±0.25°C from 70° to 100°C (±0.45°F from 158° to 212°F) Resolution 0.02°C (0.036°F) Drift <0.01°C (0.018°F) per year Response Time Without solar radiation shield: 2 minutes, 30 seconds in air moving 1 m/sec With RS3-B solar radiation shield: 5 minutes in air moving 1 m/sec Wireless Mote Operating Temperature Range -25° to 60°C (-13° to 140°F) with rechargeable batteries -40 to 70°C (-40 to 158°F) with lithium batteries Radio Power 12.6 mW (+11 dBm) non-adjustable Transmission Range At least 304.8 m (1,000 ft) line of sight at 1.8 m (6 ft) from the ground, 457.2 m (1,500 ft) typical Wireless Data Standard IEEE 802.15.4 Radio Operating Frequencies RXW-TMB-900: 904–924 MHz RXW-TMB-868: 866.5 MHz RXW-TMB-922: 916–924 MHz Modulation Employed OQPSK (Offset Quadrature Phase Shift Keying) Data Rate Up to 250 kbps, non-adjustable Duty Cycle <1% Maximum Number of Motes 50 motes per one RX Wireless Sensor Network Battery Type/ Power Source Two AA 1.2 V rechargeable NiMH batteries powered by built-in solar panel or two AA 1.5 V lithium batteries for operating conditions of -40 to 70°C (-40 to 158°F) Battery Life With NiMH batteries: Typical 3–5 years when operated in the temperature range -20° to 40°C (-4°F to 104°F) and positioned toward the sun (see Deployment and Mounting), operation outside this range will reduce the battery service life With lithium batteries: 1 year, typical use Dimensions Sensor: 5.1 x 33 mm (0.2 x 1.3 inches) Cable length: 5 m (16.4 ft) Mote: 16.2 x 8.59 x 4.14 cm (6.38 x 3.38 x 1.63 inches) Weight Sensor and cable: 82.5 g (2.91 oz) Mote: 223 g (7.87 oz) Materials Sensor: Stainless steel waterproof tip Mote: PCPBT, silicone rubber seal Environmental Rating Sensor and cable: Immersion in water up to 50°C (122°F) for 1 year Mote: IP67 Accessory: • Solar radiation shield (RS3-B) Compliance Marks RXW-TMB-900: See last page RXW-TMB-868: The CE Marking identifies this product as complying with all relevant directives in the European Union (EU). RXW-TMB-922: See last page 22243-3 RXW Temperature Sensor (RXW-TMB-xxx) Manual USB Port: Use this port to connect to the mote to a computer via USB cable if you need to update the firmware (see Updating Mote Firmware). Mote Components and Operation Mounting Tab Solar Panel Button: Push this button for 1 second to illuminate the LCD or 3 seconds for the mote to search for an RX Wireless Sensor Network to join (see Adding the Mote to the RX Wireless Sensor Network). Latch LCD Screen: The mote is equipped with an LCD screen that displays details about the current status. This example shows all symbols illuminated on the LCD screen followed by definitions of each symbol in the table. Eyelet Ground Wire Port Sensor Cable Sensor Mote Closed, Front Solar Panel Cable Sensor Mote Closed, Back LED Antenna LCD Symbol LCD Screen This is a signal strength indicator. The more bars, the stronger the signal between motes. This icon will blink when you press the button on the mote to search for a network to join (see Adding the Mote to the RX Wireless Sensor Network for details). Button LED Description The battery indicator shows the approximate battery charge remaining. USB Port Battery Holder This indicates that the mote is not part of a network. See Adding the Mote to the RX Wireless Sensor Network for details on how to add a mote to the network. Sensor Mote Opened Mounting Tab: Use the tabs at the top and bottom of the mote to mount it (see Deploying and Mounting). This indicates a problem with the sensor itself (the mote is operational). Check the sensor and make any adjustments to it as needed. Contact Onset Technical Support if the problem persists. Solar Panel: Position the solar panel towards the sun to charge the mote batteries (see Deploying and Mounting). Sensor Cable: This is the cable that connects the mote to the sensor. Adding the Mote to the RX Wireless Sensor Network Eyelet: Use this eyelet to attach a 3/16 inch padlock to the mote for security. The mote must join an RX Wireless Sensor Network before it can begin measuring temperature and transmitting data. This requires accessing the RX3000 Station and the mote at the same time so it is recommended that you complete these steps before deploying the mote. Latch: Use the two latches to open and close the mote door. Ground Wire Port: Use this port to connect a ground wire (see Deploying and Mounting). Antenna: This is the built-in antenna for the radio communications across the RX Wireless Sensor Network. Important: If you have not configured the RX3000 Station with the RXW Manager, follow the instructions in the RX3000 Quick Start before continuing. Solar Panel Cable: This cable connects the built-in solar panel to the mote circuitry. To add a mote to the RX Wireless Sensor Network: LEDs: The blue LED to the left of the LCD screen blinks at 4 seconds during normal operation. It blinks more frequently when initially joining a network. If the mote is not currently part of a network, the blue LED will be off. If the LED is on and not blinking, there is a problem with the mote. Contact Technical Support at www.onsetcomp.com/support/contact. The yellow-green LED to the upper right of the batteries only blinks during the process of joining a network. 1. If the LCD is blank on the RX3000 station, press any button to wake it up. Battery Holder: The location where the rechargeable AA batteries are installed as shown (see Battery Information). 1-800-LOGGERS www.onsetcomp.com RXW Temperature Sensor (RXW-TMB-xxx) Manual 2. Press the Select button once (which shows the number of smart sensors installed) and then press it again once if the HOBO RXW Manager is installed in the left slot (module 1) or twice if it is installed on the right slot (module 2). 7. Press the Search button (the magnifying glass) on the RX3000 Station to stop searching for motes. Press this button again to stop searching for motes Press this button to view the module where the RXW Manager is installed Measurements will be recorded at the logging interval specified in HOBOlink, transmitted to the RX3000 Station, and uploaded to HOBOlink at the next connection interval (readout). Use HOBOlink to monitor mote status and health. If a mote is temporarily offline, any logged data is saved until it is back online. In addition, if a mote is offline for 30 minutes, the RX3000 Station will automatically connect to HOBOlink and report the mote as missing. Once the mote is back online, any logged data will be uploaded the next time the RX3000 station connects to HOBOlink. 3. Press the Search button (the magnifying glass). The magnifying glass icon will blink while the RX3000 is in search mode. See the HOBOlink Help for details on how to change the logging and connection intervals, view data, check mote status, add the mote to a map, and more. Press this button so the station is ready to have motes join the network 4. Open the mote door and install the batteries if you have not already done so. Deployment and Mounting 5. Press the button on the mote for 3 seconds. The signal strength icon will flash and then cycle. Mounting and Positioning the Mote • Use cable ties to mount the mote via the holes on the mounting tabs. • Avoid mounting the mote near metal, which can cause interference with the signal. • Position the mote towards the sun, making sure the solar panel is oriented so that it receives optimal sunlight throughout each season. It may be necessary to periodically adjust the mote position as the path of the sunlight changes throughout the year or if tree and leaf growth alters the amount of sunlight reaching the solar panel. Press this button for 3 seconds for the mote to join the network 6. Watch the LCD on the mote. The signal strength icon and the LEDs will quickly blink while the mote searches for the wireless network. Once it has found the network, the icon will stop blinking and the signal strength bars will slowly cycle from left to right. As the mote completes its registration process with the network, the “x” icon to the right of the signal strength icon will flash and the yellowgreen LED will stop blinking. Once the registration is complete, the signal strength bars will stop cycling and remain solid and the channel count on the RX3000 LCD will be updated. This process may take up to five minutes. Note: The channel count on the LCD will increase by 2: one for temperature and one for the mote battery. 1-800-LOGGERS • Make sure the mote door is closed, with both latches fully locked to ensure a watertight seal. • Consider using a 3/16 inch padlock to restrict access to the mote. With the mote door closed, hook a padlock through the eyelet on the right side of the door and lock it. • To maximize the communication between motes, place the mote within 304.8–457.2 m (1,000–1,500 feet) and full line of sight with the next mote in the network and at least 1.8 m (6 feet) from the ground. • If there is an obstruction between two sensor motes or between the sensor mote and the RXW Manager, then use an RXW Repeater (RXW-RPTR-xxx) mounted higher than the two motes. For example, if there is a hill or mountain between the sensor mote and the RXW Manager, place a repeater at the top of the hill between the sensor mote and the RXW Manager. www.onsetcomp.com RXW Temperature Sensor (RXW-TMB-xxx) Manual • There should not be more than five motes in any direction from a repeater or the RXW Manager. Data logged by a wireless sensor must travel or “hop” across the wireless network from one mote to the next until it ultimately reaches the RXW Manager at the RX3000 station. To make sure the data can successfully travel across the network, the sensor mote should not be more than five hops away from a repeater or manager. above 50°C (122°F) is not recommended and may significantly reduce the life of the sensor. Maintenance The temperature sensor does not require any maintenance other than an occasional cleaning. If necessary, rinse the sensor and cable with mild soap and fresh water. The mote is designed for outdoor use, but should be inspected periodically. When inspecting the mote, do the following: • The RX Wireless Sensor Network can support a maximum of 50 motes. • Verify the mote is free of visible damage or cracks. • Use a #4-40 screw to attach a ground wire to the port on the back of the mote if you are deploying the mote in a location where lightning is a concern. • Make sure the mote is clean. Wipe off any dust or grime with a damp cloth. • Wipe off any water before opening the mote. • Make sure the mote remains in a vertical position once it is placed in its deployment location for optimal network communications. • Make sure the interior seal is intact and the latches are fully locked when the mote door is closed. Verifying Sensor Accuracy Sensor Mounting Guidelines • Mount the sensor so that at least 10 cm (4 inches) of the sensor cable is placed in the medium that is being measured. The temperature sensor is approximately 0.32 cm (0.126 inches) from the end of the stainless steel tip. It is recommended that you check the accuracy of the temperature sensor annually. The temperature sensor cannot be calibrated. Onset uses precision components to obtain accurate measurements. If the sensor is not providing accurate data, then it may be damaged or worn out if it has been in use for several years. • If the sensor cable is left on the ground, it is recommended that you use conduit to protect against animals, lawn mowers, exposure to chemicals, etc. Updating Mote Firmware • If you are mounting the sensor in water, place the sensor cable on the side of the mounting post facing downstream. This helps protect the sensor cable from getting damaged by floating debris. If a new firmware version is available for the mote, use HOBOlink to download the file to your computer. Connect the mote to the computer with a USB cable (open the mote door and use the USB port to the right of the LCD). The mote appears as a new storage device in the computer’s file storage manager. Copy the downloaded firmware file to the new storage device (the mote). After the file is copied, eject the storage device from the computer and disconnect the cable from the mote. The file will be installed automatically on the mote. Note to Mac® users: A message may appear indicating the disk has not ejected properly. The mote is operational and you can ignore the message. • The solar radiation shield (RS3-B) is strongly recommended when measuring outdoor air temperatures in direct sunlight. Solar radiation can significantly affect the air temperature readings. Use the cable ties included with the solar radiation shield (RS3-B) to secure the sensor in the radiation shield as shown (see the Solar Radiation Shield manual for additional assembly details). Battery Information The mote uses two 1.2 V rechargeable NiMH batteries, charged by the built-in solar panel. The quality and quantity of solar light can affect whether the battery is sufficiently charged to last through the night and cloudy periods. Make sure the mote is placed in a location that will receive several hours of sunlight each day. If the mote does not receive enough sunlight to recharge the batteries, the battery life is estimated at 3–4 months. When batteries are regularly recharged, expected battery life is estimated at 3–5 years. Battery life varies based on the ambient temperature where the mote is deployed, the logging interval, the number of tripped alarms, and other factors. Deployments in extremely cold or hot temperatures can impact battery life. Estimates are not guaranteed due to uncertainties in initial battery conditions and operating environment. • To minimize measurement errors due to ambient RF, keep the probe cable as far as possible from other cables. • Refer to the station manual and Tripod Setup Guide at www.onsetcomp.com/support/manuals for more information regarding setting up stations. Sensor Operating Environment The temperature sensor can be used in air, soil, or water. The sensor is designed to last at least one year in water as warm as 50°C (122°F). If the sensor is continually exposed to water for more than a year, it will eventually drift. Exposure to water 1-800-LOGGERS Mote operation will stop when battery voltage drops to 1.8 V. Mote operation will return if the battery recharges to 2.3 V. If the batteries are unable to be recharged, replace them with fresh rechargeable batteries. www.onsetcomp.com RXW Temperature Sensor (RXW-TMB-xxx) Manual To replace rechargeable batteries: 1. Open the mote door. 2. Remove the old batteries and install the new ones observing polarity. 3. Make sure the solar panel cable is plugged in. Make sure solar panel cable is installed when using rechargeable batteries You can use two 1.5 V lithium batteries (HWSB-LI) for operation at the extreme ends of the mote operating range. Lithium battery life is an estimated at 1 year, but varies based on the ambient temperature where the mote is deployed, the logging interval, the number of tripped alarms, and other factors. Estimates are not guaranteed due to uncertainties in initial battery conditions and operating environment. When using lithium batteries, you must disconnect the solar panel cable because the batteries will not be recharged. To install lithium batteries: 1. Open the mote door. 2. Remove any old batteries and install the new ones observing polarity. 3. Push in the side tab of the solar panel cable connector and pull the connector out of the cable port. 4. Place the connector in the slot on the inside of the mote door. Make sure the solar panel cables are tucked inside the door so that they do not interfere with the interior seal when the mote is closed. Store the solar panel connector here when using lithium batteries WARNING: Do not cut open, incinerate, heat above 85°C (185°F), or recharge the batteries. The batteries may explode if the logger is exposed to extreme heat or conditions that could damage or destroy the battery cases. Do not mix battery types, either by chemistry or age; batteries may rupture or explode. Do not dispose of the logger or batteries in fire. Do not expose the contents of the batteries to water. Dispose of the batteries according to local regulations. 1-800-LOGGERS www.onsetcomp.com RXW Temperature Sensor (RXW-TMB-xxx) Manual Federal Communication Commission Interference Statement This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one of the following measures: • Reorient or relocate the receiving antenna • Increase the separation between the equipment and receiver • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected • Consult the dealer or an experienced radio/TV technician for help This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. FCC Caution: Any changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate this equipment. Industry Canada Statements This device complies with Industry Canada license-exempt RSS standard(s). Operation is subject to the following two conditions: (1) this device may not cause interference, and (2) this device must accept any interference, including interference that may cause undesired operation of the device. Avis de conformité pour l’Industrie Canada Le présent appareil est conforme aux CNR d'Industrie Canada applicables aux appareils radio exempts de licence. L'exploitation est autorisée aux deux conditions suivantes : (1) l'appareil ne doit pas produire de brouillage, et (2) l'appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est susceptible d'en compromettre le fonctionnement. To comply with FCC and Industry Canada RF radiation exposure limits for general population, the logger must be installed to provide a separation distance of at least 20cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. 1-800-LOGGERS (564-4377) • 508-759-9500 www.onsetcomp.com/support/contact © 2018 Onset Computer Corporation. All rights reserved. Onset, HOBO, and HOBOlink are registered trademarks of Onset Computer Corporation. Mac is a registered trademark of Apple Inc. All other trademarks are the property of their respective companies. 22243-3
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.4 Linearized : No XMP Toolkit : Adobe XMP Core 5.2-c001 63.139439, 2010/09/27-13:37:26 Format : application/pdf Creator : Onset Computer Corporation Title : RXW Temperatuer Sensor (RXW-TMB-xxx) Manual Create Date : 2018:02:16 09:10:56-05:00 Creator Tool : PScript5.dll Version 5.2.2 Modify Date : 2018:02:16 09:11:45-05:00 Metadata Date : 2018:02:16 09:11:45-05:00 Producer : Acrobat Distiller 10.1.16 (Windows) Document ID : uuid:cd38d313-36b4-44d6-8bfd-fe01ac65688c Instance ID : uuid:010f49f0-4d1f-4c47-8b80-d8f3266f2c03 Page Count : 6 Author : Onset Computer Corporation Warning : [Minor] Ignored duplicate Info dictionaryEXIF Metadata provided by EXIF.tools
