Onset Computer ONST6 HOBO RX Wireless Sensor Network User Manual 22244 2 RXW RGx Manual
Onset Computer Corporation HOBO RX Wireless Sensor Network 22244 2 RXW RGx Manual
Contents
- 1. User Manual_22241-2 RXW-SMx Manual.pdf
- 2. User Manual_22242-2 RXW-THC Manual.pdf
- 3. User Manual_22243-3 RXW-TMB Manual.pdf
- 4. User Manual_22244-2 RXW-RGx Manual.pdf
- 5. User Manual_22245-2 RXW-WCF Manual.pdf
- 6. User Manual_22246-2 RXW-LIA Manual.pdf
- 7. User Manual_22247-2 RXW-LIB Manual.pdf
- 8. User Manual_22248-2 RXMOD-RXW Manual.pdf
- 9. User Manual_22249-2 RXW-RPTR Manual.pdf
- 10. User Manual_22436-1 RXW-OBUS Manual.pdf
- 11. User Manual_22437-1 RXW-ANA Manual.pdf
- 12. User Manual_22438-1 RXW-SPER Manual.pdf
User Manual_22244-2 RXW-RGx Manual.pdf
HOBO® RX Wireless Sensor Network RXW Davis® 0.01" or 0.2 mm Rain Gauge Sensor (RXW-RGx-xxx) Manual This sensor measures rainfall and is designed to work with the HOBO RX Wireless Sensor Network in which data is transmitted wirelessly from the sensor mote across the network to the RX3000 station and then uploaded to HOBOlink® web-based software. With HOBOlink, you can monitor sensor readings, view graphs, set up alarms, download data, and more. Specifications Sensor RXW Davis 0.01" or 0.2 mm Rain Gauge Sensor Models: • RXW-RGE-900 and RXW-RGF-900 (US) • RXW-RGE-868 and RXW-RGF-868 (Europe) • RXW-RGE-922 and RXW-RGF-922 (Australia/NZ) Items Included: Measurement Range 0 to 10.2 cm (0 to 4 in.) per hour, maximum 4,000 tips per logging interval Accuracy ±4.0%, ±1 rainfall count between 0.2 and 50.0 mm (0.01 and 2.0 in.) per hour; ±5.0%, ±1 rainfall count between 50.0 and 100.0 mm (2.0 and 4.0 in.) per hour Resolution 0.01 in. (RXW-RGE-xxx) or 0.2 mm (RXW-RGF-xxx) Calibration Requires annual calibration; can be field calibrated Wireless Mote Operating Temperature Range Mote: -25° to 60°C (-13° to 140°F) with rechargeable batteries -40 to 70°C (-40 to 158°F) with lithium batteries Radio Power 12.6 mW (+11 dBm) non-adjustable Transmission Range At least 304.8 m (1,000 ft) line of sight at 1.8 m (6 ft) from the ground, 457.2 m (1,500 ft) typical Wireless Data Standard IEEE 802.15.4 Radio Operating Frequencies RXW-RGE-900 and RXW-RGF-900: 904–924 MHz RXW-RGE-868 and RXW-RGF-868: 866.5 MHz RXW-RGE-922 and RXW-RGF-922: 916–924 MHz Modulation Employed OQPSK (Offset Quadrature Phase Shift Keying) Data Rate Up to 250 kbps, non-adjustable Duty Cycle <1% Maximum Number of Motes 50 motes per one RX Wireless Sensor Network Battery Type/ Power Source Two AA 1.2V rechargeable NiMH batteries, powered by built-in solar panel or two AA 1.5 V lithium batteries for operating conditions of -40 to 70°C (-40 to 158°F) Battery Life With NiMH batteries: Typical 3–5 years when operated in the temperature range -20° to 40°C (-4°F to 104°F) and positioned toward the sun (see Deployment and Mounting), operation outside this range will reduce the battery service life With lithium batteries: 1 year, typical use Dimensions Sensor: 16.5 cm opening diameter (6.5 in.) x 24 cm (9.5 in.) high; 214 cm2 (33.2 in.2) collection area Cable length: 2 m (6.6 ft) Mote: 16.2 x 8.59 x 4.14 cm (6.38 x 3.38 x 1.63 inches) Weight Sensor and cable: 1.2 kg (2.7 lbs) Mote: 223 g (7.87 oz) Materials Sensor: UV-stabilized ABS plastic housing; tipping bucket mechanism with magnetic reed switch pivots on metal shaft Mote: PCPBT, silicone rubber seal Environmental Rating Sensor: Weatherproof Mote: IP67 • Cable ties Items required: • Electrical tape or weatherresistant cable ties If mounting on pole or mast: • 7/16 inch combination wrench If mounting on flat surface: • Drill with 5 mm (3/16 inch) drill bit • Adjustable wrench Accessories: • Guy wire kit (M-GWA) • 1.5 meter mast (M-MPB) • Mast level (M-MLA) Compliance Marks RXW-RGE-900 and RXW-RGF-900: See last page RXW-RGE-868 and RXW-RGF-868: The CE Marking identifies this product as complying with all relevant directives in the European Union (EU). RXW-RGE-922 and RXW-RGF-922: See last page 22244-2 Rain Gauge Smart Sensor (S-RGC-M002 & S-RGD-M002) Manual USB Port: Use this port to connect to the mote to a computer via USB cable if you need to update the firmware (see Updating Mote Firmware). Mote Components and Operation Mounting Tab Solar Panel Button: Push this button for 1 second to illuminate the LCD or 3 seconds for the mote to search for an RX Wireless Sensor Network to join (see Adding the Mote to the RX Wireless Sensor Network). Latch LCD Screen: The mote is equipped with an LCD screen that displays details about the current status. This example shows all symbols illuminated on the LCD screen followed by definitions of each symbol in the table. Eyelet Ground Wire Port Sensor Cable Sensor Mote Closed, Front Solar Panel Cable Sensor Mote Closed, Back LED Antenna LCD Symbol LCD Screen This is a signal strength indicator. The more bars, the stronger the signal between motes. This icon will blink when you press the button on the mote to search for a network to join (see Adding the Mote to the RX Wireless Sensor Network for details). Button LED Description The battery indicator shows the approximate battery charge remaining. USB Port Battery Holder This indicates that the mote is not part of a network. See Adding the Mote to the RX Wireless Sensor Network for details on how to add a mote to the network. Sensor Mote Opened Mounting Tab: Use the tabs at the top and bottom of the mote to mount it (see Deploying and Mounting). Sensor Components and Operation Solar Panel: Position the solar panel towards the sun to charge the mote batteries (see Deploying and Mounting). Rain enters the collector cone, passes through a debris-filtering screen, and collects in one chamber of the tipping mechanism. The tipping spoon tips when it has collected an amount of water equal to the increment in which the sensor measures (0.2 mm or 0.01 inch). As the spoon tips, it causes a switch closure and brings the second tipping spoon chamber into position. The rain water drains out through the screened drains in the base of the collector. Sensor Cable: This is the cable that connects the mote to the sensor. Eyelet: Use this eyelet to attach a 3/16 inch padlock to the mote for security. Latch: Use the two latches to open and close the mote door. Ground Wire Port: Use this port to connect a ground wire (see Deploying and Mounting). The sensor includes the components shown on the following diagrams. The sensor includes a hardware kit with the items most commonly needed for installation. The items you use from the kit depend on where you install the sensor. You may need to adapt or purchase additional hardware to fit your individual requirements. Antenna: This is the built-in antenna for the radio communications across the RX Wireless Sensor Network. Solar Panel Cable: This cable connects the built-in solar panel to the mote circuitry. LEDs: The blue LED to the left of the LCD screen blinks at 4 seconds during normal operation. It blinks more frequently when initially joining a network. If the mote is not currently part of a network, the blue LED will be off. If the LED is on and not blinking, there is a problem with the mote. Contact Technical Support at www.onsetcomp.com/support/contact. The yellow-green LED to the upper right of the batteries only blinks during the process of joining a network. Battery Holder: The location where the rechargeable AA batteries are installed as shown (see Battery Information). These are the internal components on the base. 1-800-LOGGERS www.onsetcomp.com Rain Gauge Smart Sensor (S-RGC-M002 & S-RGD-M002) Manual 5. Press the button on the mote for 3 seconds. The signal strength icon will flash and then cycle. Press this button for 3 seconds for the mote to join the network 6. Watch the LCD on the mote. The signal strength icon and the LEDs will quickly blink while the mote searches for the wireless network. Once it has found the network, the icon will stop blinking and the signal strength bars will slowly cycle from left to right. As the mote completes its registration process with the network, the “x” icon to the right of the signal strength icon will flash and the yellowgreen LED will stop blinking. Once the registration is complete, the signal strength bars will stop cycling and remain solid and the channel count on the RX3000 LCD will be updated. This process may take up to five minutes. Note: The channel count on the LCD will increase by 2: one for rainfall and one for the mote battery. Adding the Mote to the RX Wireless Sensor Network The mote must join an RX Wireless Sensor Network before it can begin measuring rainfall and transmitting data. This requires accessing the RX3000 Station and the mote at the same time so it is recommended that you complete these steps before deploying the mote. Important: If you have not configured the RX3000 Station with the RXW Manager, follow the instructions in the RX3000 Quick Start before continuing. 7. Press the Search button (the magnifying glass) on the RX3000 Station to stop searching for motes. To add a mote to the RX Wireless Sensor Network: 1. If the LCD is blank on the RX3000 station, press any button to wake it up. 2. Press the Select button once (which shows the number of smart sensors installed) and then press it again once if the HOBO RXW Manager is installed in the left slot (module 1) or twice if it is installed on the right slot (module 2). Press this button again to stop searching for motes Measurements will be recorded at the logging interval specified in HOBOlink, transmitted to the RX3000 Station, and uploaded to HOBOlink at the next connection interval (readout). Use HOBOlink to monitor mote status and health. If a mote is temporarily offline, any logged data is saved until it is back online. In addition, if a mote is offline for 30 minutes, the RX3000 Station will automatically connect to HOBOlink and report the mote as missing. Once the mote is back online, any logged data will be uploaded the next time the RX3000 station connects to HOBOlink. Press this button to view the module where the RXW Manager is installed 3. Press the Search button (the magnifying glass). The magnifying glass icon will blink while the RX3000 is in search mode. See the HOBOlink Help for details on how to change the logging and connection intervals, view data, check mote status, add the mote to a map, and more. Deployment and Mounting Mounting and Positioning the Mote • Use cable ties to mount the mote via the holes on the mounting tabs. Press this button so the station is ready to have motes join the network • Avoid mounting the mote near metal, which can cause interference with the signal. 4. Open the mote door and install the batteries if you have not already done so. 1-800-LOGGERS www.onsetcomp.com Rain Gauge Smart Sensor (S-RGC-M002 & S-RGD-M002) Manual • Position the mote towards the sun, making sure the solar panel is oriented so that it receives optimal sunlight throughout each season. It may be necessary to periodically adjust the mote position as the path of the sunlight changes throughout the year or if tree and leaf growth alters the amount of sunlight reaching the solar panel. the rain gauge at least 4 cm (1 inch) away from any steel or iron surface and make sure the reed switch is at least 4 cm (1 inch) away from any steel or iron objects (e.g. nails). • For the most accurate rainfall measurements, it is recommended that you mount the sensor upslope, about 3 meters (10 feet) away from the tripod, on a 1.5 meter high mounting pole (M-MPB). Alternatively, you can mount the sensor on the tripod mast. • Make sure the mote door is closed, with both latches fully locked to ensure a watertight seal. • Tall objects can interfere with accurate rain measurements. It is recommended that you place the rain bucket away from the obstruction by a distance greater than three times the height of the obstruction. If that is not possible, raise the rain bucket as high as possible to avoid shedding. • Consider using a 3/16 inch padlock to restrict access to the mote. With the mote door closed, hook a padlock through the eyelet on the right side of the door and lock it. • To maximize the communication between motes, place the mote within 304.8–457.2 m (1,000–1,500 feet) and full line of sight with the next mote in the network and at least 1.8 m (6 feet) from the ground. • Avoid splashing and puddles. Be sure the gauge is high enough above any surface that rain will not splash into the top of the collector. • If there is an obstruction between two sensor motes or between the sensor mote and the RXW Manager, then use an RXW Repeater (RXW-RPTR-xxx) mounted higher than the two motes. For example, if there is a hill or mountain between the sensor mote and the RXW Manager, place a repeater at the top of the hill between the sensor mote and the RXW Manager. • Vibration can significantly degrade accuracy of the tipping bucket mechanism. In windy locations make sure that the bucket will be vibration-free. Consider using guy wires to secure a pole or tower-mounted bucket. Preparing the Sensor for Mounting • There should not be more than five motes in any direction from a repeater or the RXW Manager. Data logged by a wireless sensor must travel or “hop” across the wireless network from one mote to the next until it ultimately reaches the RXW Manager at the RX3000 station. To make sure the data can successfully travel across the network, the sensor mote should not be more than five hops away from a repeater or manager. 1. Remove the cone from the base by turning over the bucket. Rotate the base counterclockwise until the latches on the cone line up with the latch openings in the base, then lift the base off the cone. • The RX Wireless Sensor Network can support a maximum of 50 motes. • Use a #4-40 screw to attach a ground wire to the port on the back of the mote if you are deploying the mote in a location where lightning is a concern. • Make sure the mote remains in a vertical position once it is placed in its deployment location for optimal network communications. 2. The tipping bucket on the base has been secured to avoid possible damage to the assembly. Carefully cut and remove the cable tie to release the bucket assembly. Sensor Mounting Guidelines Use the following guidelines to determine the best location for installing the sensor. • You must mount the rain gauge sensor so that it is level. As built-in bubble level is attached to the base to simplify this process. • Be sure there is an unobstructed path for water runoff from the drain screens. • The sensor contains a magnet-operated switch that may not operate correctly if you mount the rain gauge on or near any object that is attracted to a magnet. Mounting the Sensor on a Wooden Post or Flat Surface 1. With a 5 mm (3/16 inch) drill bit, drill two holes approximately 54 mm (2-1/8 inches) apart. Use the metal backing plate as a guide when marking the holes and a carpenter’s level to ensure the holes are level. • Exposure to winds can reduce the measured rainfall amounts. Mount the sensor where there are no obstructions of rainfall at low angles (such as trees, houses, fences) and as low as possible out of the wind. 2. Insert the 1/4 inch x 3 inch lag screws through the metal backing plate and the holes in the mounting base into the post. Make sure the base is level by checking the built-in bubble level. • If installing the sensor on a sheet metal roof, insulate the unit by making a platform out of wood. Mount the base of 1-800-LOGGERS www.onsetcomp.com Rain Gauge Smart Sensor (S-RGC-M002 & S-RGD-M002) Manual 3. Tighten the lag screws using an adjustable wrench or 7/16 inch wrench. Mounting the Sensor on a Pole or Mast 2. Place the cone back onto the base by putting the latches on the cone into the latch openings in the base and rotating the cone clockwise until the latches “lock” into place. As you reattach the cone, make sure to run the cable through the cable slot in the base or the cone will not fit snugly against the base. With the supplied U-bolt, the rain collector can be mounted on a pole having an outside diameter ranging from 32 to 44 mm (1-1/4 to 1-3/4 inch). A larger U-bolt (not supplied) can be used to mount to a pole with a maximum outside diameter of 64 mm (2-1/2 inch). To mount on a smaller pole, obtain a U-bolt that fits the base openings but has a shorter threaded section. If the included Ubolt is used with a smaller pole, the bolt will interfere with the rain collector cone. Place cable in groove to ensure the cone is properly aligned with the base Use the built-in bubble level to ensure the sensor is level. 1. While holding the mounting base against the pole, place the two ends of a U-bolt around the pole and through the two holes in the base. 2. Slide the metal backing plate over the bolt ends as they stick out toward the rain collector cone. Secure the backing plate with a washer, a lock washer, and a hex nut on each of the bolt ends. Adjust the height of the rain collector, then tighten the nuts. 3. Place the debris screen, pointed end up, into the cone. The screen prevents large bits of debris from blocking the funnel hole. If bird nesting is a problem, you can place a spike in the hole on top of the debris screen. Note that using a bird spike in the debris screen may make the screen more likely to be blown over or out in a high wind gust. 4. To prevent fraying or cutting the cable where it is exposed to weather, secure it so it does not whip about in the wind. Use electrical tape or weather resistant cable ties to secure the cable. Place tape or ties approximately every 1 to 1.6 m (3 to 5 ft). Do not use metal staples to secure cables as they can cut the cables. Make sure there are drip loops on both sides of the sensor housing, which must also be mounted horizontally as described under Sensor Mounting Guidelines. Completing the Sensor Installation Maintenance 1. To use bird spikes, insert one spike into each socket around the rim of the cone. The sockets are tapered; push firmly or tap lightly with a hammer for a more secure fit. Be careful; bird spikes may be sharp. Note: If you choose not to install the bird spikes, we recommend that you keep the packet of spikes in case birds become a problem in the future. 1-800-LOGGERS For greatest accuracy, you should thoroughly clean the sensor at least once or twice a year. 1. Separate the cone from the base. 2. Use a soft damp cloth to clean pollen, dirt, and other debris from the cone, cone screens, and bucket. www.onsetcomp.com Rain Gauge Smart Sensor (S-RGC-M002 & S-RGD-M002) Manual 3. Use a pipe cleaner to clear the funnel hole in the cone and the drain screens in the base. When all parts are clean, rinse with clear water. ejected properly. The mote is operational and you can ignore the message. Battery Information 4. Reattach the cone and replace the screen. The mote uses two 1.2 V rechargeable NiMH batteries, charged by the built-in solar panel. The quality and quantity of solar light can affect whether the battery is sufficiently charged to last through the night and cloudy periods. Make sure the mote is placed in a location that will receive several hours of sunlight each day. If the mote does not receive enough sunlight to recharge the batteries, the battery life is estimated at 3–4 months. When batteries are regularly recharged, expected battery life is estimated at 3–5 years. Battery life varies based on the ambient temperature where the mote is deployed, the logging interval, the number of tripped alarms, and other factors. Deployments in extremely cold or hot temperatures can impact battery life. Estimates are not guaranteed due to uncertainties in initial battery conditions and operating environment. The mote is designed for outdoor use, but should be inspected periodically. When inspecting the mote, do the following: • Verify the mote is free of visible damage or cracks. • Make sure the mote is clean. Wipe off any dust or grime with a damp cloth. • Wipe off any water before opening the mote. • Make sure the interior seal is intact and the latches are fully locked when the mote door is closed. Field Calibration The sensor is calibrated at the factory so the spoons tip (and record rainfall) for each 0.2 mm or 0.01 inch of rain. To adjust the calibration slightly, use a 5 mm (3/16 inch) wrench to rotate the adjustment screws located underneath the tipping spoons (see diagram in Sensor Components and Operation). Do not touch the reed switch. Mote operation will stop when battery voltage drops to 1.8 V. Mote operation will return if the battery recharges to 2.3 V. If the batteries are unable to be recharged, replace them with fresh rechargeable batteries. The adjustment guide embossed in the platform shows how far you must rotate both screws in turn to effect a 1% and a 2% change. To replace rechargeable batteries: 1. Open the mote door. 2. Remove the old batteries and install the new ones observing polarity. 3. Make sure the solar panel cable is plugged in. Make sure solar panel cable is installed when using rechargeable batteries Moving the screws in the positive (+) direction causes the spoons to tip more times (i.e. give a larger count) for a given amount of water. Modify both adjustment screws by the same amount. To check the accuracy of the sensor, compare it with a tube type rain gauge. Use a rain gauge with an aperture of at least 10.2 cm (4 inches). Any smaller and the readings obtained may not be accurate. Place the tube type rain gauge directly next to the sensor. Compare the totals on three storms to determine whether your rain collector needs calibration and by how much. Adjust the screws to fine-tune the reading for the next three storms if necessary. You can use two 1.5 V lithium batteries (HWSB-LI) for operation at the extreme ends of the mote operating range. Lithium battery life is an estimated at 1 year, but varies based on the ambient temperature where the mote is deployed, the logging interval, the number of tripped alarms, and other factors. Estimates are not guaranteed due to uncertainties in initial battery conditions and operating environment. When using lithium batteries, you must disconnect the solar panel cable because the batteries will not be recharged. Updating Mote Firmware If a new firmware version is available for the mote, use HOBOlink to download the file to your computer. Connect the mote to the computer with a USB cable (open the mote door and use the USB port to the right of the LCD). The mote appears as a new storage device in the computer’s file storage manager. Copy the downloaded firmware file to the new storage device (the mote). After the file is copied, eject the storage device from the computer and disconnect the cable from the mote. The file will be installed automatically on the mote. Note to Mac® users: A message may appear indicating the disk has not 1-800-LOGGERS To install lithium batteries: 1. Open the mote door. 2. Remove any old batteries and install the new ones observing polarity. 3. Push in the side tab of the solar panel cable connector and pull the connector out of the cable port. www.onsetcomp.com RXW Davis 0.01" or 0.2 mm Rain Gauge Sensor (RXW-RGx-xxx) Manual 4. Place the connector in the slot on the inside of the mote door. Make sure the solar panel cables are tucked inside the door so that they do not interfere with the interior seal when the mote is closed. Store the solar panel connector here when using lithium batteries WARNING: Do not cut open, incinerate, heat above 85°C (185°F), or recharge the batteries. The batteries may explode if the logger is exposed to extreme heat or conditions that could damage or destroy the battery cases. Do not mix battery types, either by chemistry or age; batteries may rupture or explode. Do not dispose of the logger or batteries in fire. Do not expose the contents of the batteries to water. Dispose of the batteries according to local regulations. Federal Communication Commission Interference Statement This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one of the following measures: • Reorient or relocate the receiving antenna • Increase the separation between the equipment and receiver • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected • Consult the dealer or an experienced radio/TV technician for help This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. FCC Caution: Any changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate this equipment. Industry Canada Statements This device complies with Industry Canada license-exempt RSS standard(s). Operation is subject to the following two conditions: (1) this device may not cause interference, and (2) this device must accept any interference, including interference that may cause undesired operation of the device. Avis de conformité pour l’Industrie Canada Le présent appareil est conforme aux CNR d'Industrie Canada applicables aux appareils radio exempts de licence. L'exploitation est autorisée aux deux conditions suivantes : (1) l'appareil ne doit pas produire de brouillage, et (2) l'appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est susceptible d'en compromettre le fonctionnement. To comply with FCC and Industry Canada RF radiation exposure limits for general population, the logger must be installed to provide a separation distance of at least 20cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. 1-800-LOGGERS (564-4377) • 508-759-9500 www.onsetcomp.com/support/contact © 2018 Onset Computer Corporation. All rights reserved. Onset, HOBO, and HOBOlink are registered trademarks of Onset Computer Corporation. Some material reprinted with permission from Davis Instruments Corporation. Davis is a registered trademark of Davis Instruments Corporation. Mac is a registered trademark of Apple Inc. All other trademarks are the property of their respective companies. 22244-2
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.4 Linearized : No XMP Toolkit : Adobe XMP Core 5.2-c001 63.139439, 2010/09/27-13:37:26 Create Date : 2018:02:16 10:05:16-05:00 Creator Tool : PScript5.dll Version 5.2.2 Modify Date : 2018:02:16 10:05:57-05:00 Metadata Date : 2018:02:16 10:05:57-05:00 Producer : Acrobat Distiller 10.1.16 (Windows) Format : application/pdf Title : RXW Davis 0.01" or 0.2 mm Rain Gauge Sensor (RXW-RGx-xxx) Manual Creator : Onset Computer Corporation Document ID : uuid:e58ee38e-93c8-45c0-8edd-7f033cc0752c Instance ID : uuid:12ca4363-dd9b-4ec4-87b5-85f88f398426 Page Count : 7 Author : Onset Computer Corporation Warning : [Minor] Ignored duplicate Info dictionaryEXIF Metadata provided by EXIF.tools
