Ox Co OVS01 Vehicle detection sensor User Manual Users manual
Optex Co Ltd Vehicle detection sensor Users manual
Ox Co >
Users manual
VEHICLE DETECTION SENSOR OVS-01 BG / BGB OVS-01 CC / CCB OVS-01 PK / PKB for BARRIER GATE for CAR COUNTING for PARKING This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. FCC WARNING(For USA) Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. -NOTICEThis equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation.This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: -Reorient or relocate the receiving antenna. -Increase the separation between the equipment and receiver. -Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. -Consult the dealer or an experienced radio/TV technician for help. -NOTICE1.The antennas cannot be exchanged. 2.To comply with FCC RF exposure compliance requirements, aseparation distance of at least 20cm must be maintained between the antenna of this device and all persons. Vehicle Detection Sensor OVS-01 series 1) Product Line-Up Type designation Application OVS-01BG OVS-01BGB Barrier Gate OVS-01CC OVS-01CCB Car Counting OVS-01PK OVS-01PKB Parking OVS-01BG Operation Panel OVS-01CC Operation Panel OVS-01 PK Operation Panel Select Button Select Button Indicator Select Button Select Button Select Button 2) Specifications Item 1 Power Supply 2 Current Draw 3 Output 4 MW detection Range 5 Ultrasonic Detection Range 7 Mode Sensitivity OVS-01BGB 0.8 - 8m OVS-01CCB OVS-01CC 5 level (1,2,3,4,5) selectable by Select button OVS-01PKB OVS-01PK DC12-24V±10% Heater ON:150mA max. (Heater Off: 80mA max.) 2(Two) outputs ( Output 1/ Output 2 ) 1a Relay output 30V, 0.3A 0.8 - 5.5m 0.1 - 1.5m Fixed 0.8 - 3m Default 3 Anti Bump Sensitivity Anti Bump Timer 0.5,1.0, 2.0, 4.0sec selectable by Select button Default 2 sec 0.5,1.0, 2.0, 4.0sec selectable by Select button Default 2 sec Off Delay 0.5,1.0, 2.0, 4.0sec selectable by Select button Default 2 sec 0.5,1.0, 2.0, 4.0sec selectable by Select button Default 2 sec On Delay 0.5,1.0, 2.0, 4.0sec selectable by Select button Default 2 sec Output 1 NO/NC select Output 2 Relay/Trouble Maximum Range (MW) Behavior Type Location Human cancel Calibration Area Check Response Time Operating temperature Operating Humidity Protection Category 15 Sensor Aiming Adjust 16 17 18 19 20 21 OVS-01BG Off, Low, Mid. High selectable by Select button Default Mid. Re-detection Timer 10 11 12 13 14 Calibration Area Check Button Button Detection Speed Reset Frequency Indicator Narrow Lens Radio approved standard NO / NC selectable by select button Default NO Output 2 NO / Output 2 NC / Trouble output NO / Trouble output NC selectable by Select button Default Output 2 NO 8 level (2, 2.5, 3, 3.5, 4, 4.5, 6, 8m) 8 level (2, 2.5, 3, 3.5, 4, 4.5, 5, 5.5m) 8 level (2.4, 2.6, 2.8, 3, 3.2, 3.4, 3.6, 3.8m) selectable by Select button Default 4m selectable by Select button Default 4m selectable by Select button Default 3.2m Activation / Vehicular Protection selectable by Select button Corner / Center selectable by Select button Equipped By Calibration button By Area Check button 500ms 500ms 300ms -30 〜50℃ 93% max. IP65 Pan : ±30° Pan : ±15° Pan : ±30° Pan : ±15° Pan : ±30° Pan : ±15° Tilt:Not available Tilt:Not available Tilt:Not available Tilt:Not available Tilt:Not available Tilt:Not available 60km/h max. 20km/h max. 20km/h max. Back to default, Press one sec. " Area Check " and " Calibration " button same time MW : 24GHz, Ultrasonic : 58KHz 3 (Three) color LED Standby :Green, Area check : Not detect Green flashing, Detect Red, Calibration : Blue flashing Equipped Equipped FCC Parts 15 Subpart C:2013, ARIB STD-T73 1.2 and R & TTE 3) Installation OVS-01BG / BGB 1. Install the Base to Square Pillar or Wall 3. Adjust Sensor Angle, Maximum Range and Behavior Type 2. Wiring 4. Calibration Press the Calibration button Indicator *Blue LED flashing (8 sec.). *Blue LED fast flashing (2 sec.) *Blue LED to Green LED *Completed 5. Area Check Press the Area Check button 6. Set the Parameter Indicator *Green LED flashing *Red flashing when detecting Human, Vehicle Test pole *Press the Area Check button or Wait for 30 sec. with Green LED flashing *Completed Anti Bump Sensitivity Anti Bump Timer Off Delay Output 2 Output 1 7. System Check 8. Put the Cover OVS-01CC / CCB 1. Install the Base to Square Pillar or Wall 3. Adjust Sensor Angle and Maximum Range 2. Wiring 4. Calibration Press the Calibration button Indicator *Blue LED flashing (8 sec.). *Blue LED fast flashing (2 sec.) *Blue LED to Green LED *Completed 5. Area Check Press the Area Check button 6. Set the Parameter Indicator *Green LED flashing *Red flashing when detecting Human, Vehicle Test pole *Press the Area Check button or Wait for 30 sec. with Green LED flashing *Completed 7. System Check 8. Put the Cover Off Delay Output 2 Output 1 OVS-01PK / PKB 1. Install the Base to Square Pillar or Wall 3. Adjust Sensor Angle and Maximum Range 2. Wiring 4. Calibration Press the Calibration button Indicator *Blue LED flashing (8 sec.). *Blue LED fast flashing (2 sec.) *Blue LED to Green LED *Completed 5. Area Check Press the Area Check button Indicator *Green LED flashing *Red flashing when detecting Human, Vehicle Test pole *Press the Area Check button or Wait for 30 sec. with Green LED flashing *Completed 6. Set the Parameter Off Delay Output 2 Output 1 7. System Check 8. Put the Cover 4) How to check the Detection Area For the detection area checking, we recommend to use diameter 60mm pole (Height around 1m~1.5m) as standard. Example Bar Assumed Loop Coil area (LC1) Assumed Loop Coil area (LC2) [3] [1] [5] [4] [2] Checking Pole OVS-01BG Behavior Position :Activation OVS-01BG Behavior Position : Safety 1. Press the Area Check button 2. Check the Indicator turn to Green flashing 7. Check the checking pole to near the Bar [ 5 ] 8. Check the Indicator turn to Green LED flashing (Not detect pole) Area Check button 3. Put the Checking Pole to corner of assumed loop coil area [ 1 ] 4. Leave from detection area 5. Check the indicator turn to Red flashing 9. Press the Area Check button or wait for 30 sec. With Green LED flashing 10. Completed. 6. Repeat 3-5 for [ 2 ] [ 3 ] and [ 4 ] Checking Pole Example [1] Bar [2] S1 OVS-01BG 1. Press the " Area Check " button 2. Check the indicator turn on to Green LED flashing. 7. Check the checking pole to near the Bar [ 2 ] 8. Check the Indicator turn to Green LED flashing (Not detect pole) (keep Green flashing) Area Check button 3. Put the checking pole to expected area Top [ 1 ] 4. Leave from detection area 5. Check the indicator turn to Red flashing 9. Press the Area Check button or wait for 30 sec. With Green LED flashing 10. Completed. Other Precaution 1. The detection area of Ultrasonic sensor should not contact with anything, (the ground, flower pot, the box etc.) Example -5°OK. (Detection area is not contacting with the ground) -15°NG. (Detection area is contacting with the ground) Ground Ground Detection area of Ultrasonic Sensor 2. Mounting Height 60-80cm will have 100% performance. 3. Sensitivity Level (Human detection and Vehicle detection) The following are relation between Human cancel and Vehicle detection. Position 3 is used generally. Sensitivity Sensitivity High Low Not detect 100% not detect Two-Tree Human One Human High Low Around 92-95% not detect one Human Vehicle Detection around 99.999% Vehicle Detection Vehicle Detection around 99.9% around 97% Vehicle Detection Human Cancel 4. Anti-Bump function Anti Bump Sensitivity Off Low Mid Hig Anti Bump Time 0.5 1.0 2.0 4.0 Generally, Anti Bump Sensitivity position use " Off " position. Anti Bump Time function does not work in the Off position. However, If more safety is required to avoid the Bar contact with Vehicle, Anti-Bump function will be used. * General Application : Anti-Bump Function ( Sensitivity : Off) Gate Bar S2 Ticket Machine S1 S2 Ticket Machine Gate Bar S1 S2 Ticket Machine S1 Ticket Machine Gate Bar S2 S1 Gate Bar OVS-01BG OVS-01BG Gate Bar is down Gate Bar is Up Gate Bar is going down Gate Bar is Down * Use Anti Bump Function (Sensitivity Mid ) Gate Bar Gate Bar Gate Bar OVS-01BG S2 Ticket Machine S1 S2 S1 Ticket Machine S2 Ticket Machine S1 In this case, Bar have to be up immediately to avoid contacting with Vehicle. OVS-01BG Gate Bar is going down Gate Bar is Up Suddenly Vehicle comes back by slop etc. Note S2 Leave from the detection area S2 5) * After Vehicle leave from the detection area, Sensitivity is more sensitive for 0.5 or 1 or 2 or 4 sec. (selectable by Anti-Bump timer). (During Anti Bump function is working, Human cancel function dose not work.) * Sensitive level is selected. (Low, Mid. High ). Generally Mid position is used. Note : Anti Bump function works in the only Behavior position "Safety" 5. Off Delay Timer 0.5 Off delay Selectable Off delay time ( 0.5, 1, 2, 4 second) MW Detection Area OVS-01Sensor OVS -01 Sensor On Off 0.5 sec. Relay Output ON Off Off Delay time Off Delay time 6. Calibration * Calibration must be definitely executed after installation. * Calibration must be executed with stable parking condition.. It mean there are no Vehicle, human, Big plant pot and Box etc within the detection area when calibration is executed. Parking MW Detection Good ! Bad ! OVS-01 Calibration Button OVS-01 Sensor 7. Heater ・MW dose not work if snow is stuck to the surface of Ratome.. Radome ・Purpose of Heater is to melt the snow that is stuck to the surface of Redame. ・Heater will work when outside temperature become around 0 degree automatically. Radome surface keep around 4 degree or more by this heater. Snow is not stuck to surface of radome of 4 degree or more 1. Rain becomes snow if temperature becomes less 0 ℃. 2. 0 ℃ must be guaranteed because it is operating temperature range. 3. Heater which is attached to rear surface of radome solves this problem. 4. Heater dose not warm the electrical components inside OVS-01 5. Limit -20 degree is defined by the specification of MW, Ultrasonic Radome MW module Radome MW module Heater Radome MW module Snow Snow OK! No! OK! 8. Detection Area Ultrasonic Detection Area 250 Horizontal 150 100 100 50 50 Z [cm] 200 150 Y [cm] 200 -50 0 100 200 300 400 500 -50 0 -100 -100 -150 -150 -200 -200 -250 Vertical 250 100 -250 X [cm] MW area with Narrow Lens ・OVS-01BG / BGB This model dose not equip the narrow lens. 200 300 400 500 X [cm] MW area without Narrow Lens ・OVS-01CC / CCB / PK / PKB This model equip the narrow lens. 9. MW and Ultrasonic ・OVS-01 series equips MW and Ultrasonic sensor. ・Presence detection is possible by FMCW. ・Ultrasonic Sensor detect near side range. ・Detection logic ①MW detect a car first. ②When MW detect a car, Ultrasonic can be possible to detect. ③Output is OR gate of MW and Ultrasonic sensor. MW sensor detection area Ultrasonic sensor detection area *Car is detected by MW sensor first. *When MW detect a car, Ultra sonic sensor can be possible to detect MW sensor detection area Ultrasonic sensor detection area Human is not detected Human is not detected Car is detected by Ultrasonic sensor 10. Output * All OVS-01 series equips six terminals Power Supply DC12-24V Relay 1 output Relay 2 output Output 1 Output 2 (Sub output) (Main output) or Trouble output Select "Output 2 Relay / Trouble " by Select Button A Select NO or NC by Button Indicator (Red) Select Button A Button Indicator (Green) Select Trouble Output by Button B Select Output 2 by Button B Select Button B Select Button B Indicator (Green) Indicator (Green) Select R.N.O or R.N.C by Select Button B Select T.N.O or T.N.C by Select Button B Indicator (Green) Select Button B Indicator Select Button B Trouble Output When either MW or Ultrasonic sensor is failed (dead), it is outputted. However, This output do not understand that either Sensor is failed (dead).
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.5 Linearized : No Author : n-kageyama Create Date : 2016:02:10 09:36:28+09:00 Modify Date : 2016:02:10 09:37:16+09:00 XMP Toolkit : Adobe XMP Core 5.2-c001 63.139439, 2010/09/27-13:37:26 Format : application/pdf Title : OVS-01 取説_20160210.xlsx Creator : n-kageyama Creator Tool : PScript5.dll Version 5.2.2 Metadata Date : 2016:02:10 09:37:16+09:00 Producer : Acrobat Distiller 10.1.16 (Windows) Document ID : uuid:dae12eeb-3a2d-4af4-bd3f-6a2c5d5d2f44 Instance ID : uuid:e4242efb-0b13-4fa8-b9f2-3ebf0d2c2946 Page Count : 8EXIF Metadata provided by EXIF.tools