PBE Europe as Axell Wireless 60-0559SERIES UHF Signal Extender User Manual RECEIVER MULTICOUPLER
Axell Wireless UHF Signal Extender RECEIVER MULTICOUPLER
handbook
Pasadena Metro Radio System Maintenance Handbook For Canam Technology Inc. AFL Works Order Nō.: Q107519 AFL product part Nō’s.: 60-055900 60-056000 60-056100 PBL Location One UHF1/1A & UHF2 (This document) Tunnels 1 & 2 PBL location TWO & 800MHz BDA PBL UHF1/1A 1 & 2 Air Interface Maintenance Handbook H/book Number:-60-055900HBKM Issue No:-2 Date:-20/10/2003 Page:-1 of 85 Table of Contents AMENDMENT LIST RECORD SHEET ................................................................................................. 5 INTRODUCTION ....................................................................................................................................... 6 SCOPE ..........................................................................................................................................................................6 PURPOSE .....................................................................................................................................................................6 GLOSSARY OF TERMS .................................................................................................................................................7 AFL DRAWING SYMBOL KEYS ..................................................................................................................................8 1. 1.1 1.2 1.3 1.4 1.5 2. 3. SAFETY CONSIDERATIONS ....................................................................................................... 9 ELECTRIC SHOCK HAZARD ...........................................................................................................................9 RF RADIATION HAZARD ...............................................................................................................................9 CHEMICAL HAZARD ....................................................................................................................................10 LASER SAFETY .............................................................................................................................................11 EMERGENCY CONTACT NUMBERS ..............................................................................................................11 OVERVIEW/SYSTEM DESCRIPTION ..................................................................................... 12 SPECIFICATIONS ........................................................................................................................ 13 3.1 PARTS LISTS ................................................................................................................................................13 3.1.1 UHF1/1A & UHF2 Location ONE 60-055900 Parts List........................................................................13 3.1.1.1 F/O Air Interface 60-055901 Location ONE-UHF1 Parts List ........................................................13 3.1.1.2 F/O Air Interface 60-055902 Location ONE, UHF2 Parts List .......................................................15 3.1.1.3 F/O Air Interface 60-055903 Location ONE, UHF1A Parts List ....................................................17 3.2 TECHNICAL SPECIFICATIONS ......................................................................................................................18 3.2.1 UHF ONE to Tunnels 1 & 2 Technical Specification..............................................................................18 3.2.2 UHF1A Technical Specification ..............................................................................................................19 3.2.3 UHF ONE to Location TWO Technical Specification.............................................................................20 3.2.4 UHF TWO to Tunnels 1 & 2 Technical Specification.............................................................................21 3.2.5 UHF TWO to Location TWO Technical Specification............................................................................22 3.2.6 800MHz Bi-directional Amplifier to Location TWO Technical Specification........................................23 3.3 MECHANICAL SPECIFICATION (UHF1/1A & UHF2 WALL CASES) .........................................................24 4. 4.1 4.2 4.3 4.4 4.5 5. SYSTEM DRAWINGS .................................................................................................................. 25 DRG. NŌ. 60-055990, LOCATION ONE, UHF1/1A CASE OUTLINE DRAWING ........................................25 DRG. NŌ. 60-055994 LOCATION ONE, UHF1A (UPGRADE) CASE OUTLINE DRAWING ..........................26 DRG. NŌ. 60-055991, LOCATION ONE, UHF 2 CASE OUTLINE DRAWING ..............................................27 COMPLETE SYSTEM DIAGRAM SKETCH .....................................................................................................28 UHF1/1A & UHF2 SYSTEM DIAGRAM SKETCH .......................................................................................29 SUB-UNIT MODULES .................................................................................................................. 30 5.1 UHF 1 AIR INTERFACE (60-055901) ..........................................................................................................30 5.1.1 Bandpass Duplexers (02-013401) ............................................................................................................30 5.1.1.1 Description .......................................................................................................................................30 5.1.1.2 Technical Specification ....................................................................................................................30 5.1.2 2 & 4 Way UHF Splitters (05-002603 & 05-003401) .............................................................................31 5.1.2.1 Description .......................................................................................................................................31 5.1.2.2 Technical Specification (05-002603) ...............................................................................................31 5.1.2.3 Technical Specification 05-003401..................................................................................................31 5.1.3 ¼Watt 0- -30dB Switched Attenuator (10-000701).................................................................................32 5.1.3.1 General Application .........................................................................................................................32 5.1.3.2 Switched Attenuators .......................................................................................................................32 5.1.4 Low Noise Amplifiers (11-006102, 11-007302 & 11-007402) ...............................................................32 5.1.4.1 General Description..........................................................................................................................32 5.1.4.2 Technical Specification (11-006102) ...............................................................................................32 5.1.4.3 Drg. Nō. 11-006102, Low Noise Amplifier General Assembly.......................................................33 5.1.4.4 Drg. Nō. 11-006170, LNA RF Circuit Diagram ..............................................................................34 5.1.4.5 Drg. Nō. 11-006171, LNA DC Wiring Diagram .............................................................................35 PBL UHF1/1A 1 & 2 Air Interface Maintenance Handbook H/book Number:-60-055900HBKM Issue No:-2 Date:-20/10/2003 Page:-2 of 85 5.1.4.6 Drg. Nō. 11-003971, LNA DC Schematic Diagram ........................................................................36 5.1.4.7 Technical Specification (11-007302) ...............................................................................................37 5.1.4.8 Drg. Nō. 11-007302, LNA Assembly With Alarm Relay................................................................38 5.1.4.9 Drg. Nō. 11-007370, LNA RF Circuit Diagram ..............................................................................39 5.1.4.10 Drg. Nō. 11-007371, LNA DC Wiring Diagram .........................................................................40 5.1.4.11 Technical Specification (11-007402) ...........................................................................................41 5.1.4.12 Drg. Nō. 11-007402, LNA General Assembly.............................................................................42 5.1.4.13 Drg. Nō. 11-007470, LNA RF Circuit Diagram ..........................................................................43 5.1.4.14 Drg. Nō. 11-007471 LNA DC Wiring Diagram ..........................................................................44 5.1.5 5Watt Power Amplifier (12-001801) .......................................................................................................45 5.1.5.1 Description .......................................................................................................................................45 5.1.5.2 Technical Specification ....................................................................................................................45 5.1.5.3 Drg. Nō. 12-001801, 5Watt PA General Assembly Drawing ..........................................................46 5.1.5.4 Drg. Nō. 12-001870, 5Watt PA Circuit Diagram.............................................................................47 5.1.5.5 Drg. Nō. 12-001870C1, 5W PA Component List(1) .......................................................................48 5.1.5.6 Drg. Nō. 12-001870C2, 5W PA Component List(2) .......................................................................49 5.1.5.7 Drg. Nō. 80-008450, Power Amplifier/Alarm Board DC Wiring Details .......................................50 5.1.6 3 Stage Amplifier Alarm Boards (12-002201).........................................................................................51 5.1.6.1 Description .......................................................................................................................................51 5.1.6.2 Technical Specification ....................................................................................................................52 5.1.6.3 Drg. Nō. 12-002201, 3 Stage Alarm Board Assembly Drawing & Parts List..................................53 5.1.6.4 Drg. Nō. 12-002270, 3 Stage Alarm Board Circuit Diagram...........................................................54 5.1.6.5 Generic Wall Enclosure Alarm Wiring Sketch ................................................................................55 5.1.7 DC/DC Converter, 24V in, 12V 8A out (13-003011)..............................................................................56 5.1.7.1 Description .......................................................................................................................................56 5.1.7.2 Technical Specification ....................................................................................................................56 5.1.8 Channel Selective & Channel Control Modules (17-003012 & 17-002101) ...........................................57 5.1.8.1 Channel Selective Module Description ............................................................................................57 5.1.8.2 Drg. Nō. 17-003080, Generic Channel Module Block Diagram......................................................58 5.1.8.3 Channel Selectivity Control Module Description ............................................................................59 5.1.8.4 Channel Controller DIP Switch Configuration Frequencies ............................................................59 5.1.8.5 UHF1 Downlink Channel Module Configuration Table..................................................................60 5.1.8.6 UHF1 Uplink Channel Module Configuration Table.......................................................................60 5.1.8.7 UHF1A Downlink Channel Module Configuration Table...............................................................60 5.1.8.8 UHF1A Uplink Channel Module Configuration Table....................................................................61 5.1.8.9 UHF2 Downlink Channel Module Configuration Table..................................................................61 5.1.8.10 UHF2 Uplink Channel Module Configuration Table...................................................................61 5.1.9 Single & Dual 24Volt Relay Boards (20-001602 & 80-008902).............................................................62 5.1.9.1 24V Relay Boards (20-001602 & 80-008902) Description .............................................................62 5.1.9.2 Drg. Nō. 20-001602, Dual 24V Relay Board Assembly Drawing...................................................63 5.1.9.3 Drg. Nō. 20-001671, Dual 24V Relay Board Circuit Diagram........................................................64 5.1.9.4 Drg. Nō. 80-008970, Single Relay Board Circuit Diagram .............................................................65 5.1.10 SMA coaxial termination (93-930003) ................................................................................................66 5.1.10.1 Description ...................................................................................................................................66 5.1.11 24V 400W Flat-Pack Power Supply (96-300011) ...............................................................................66 5.1.11.1 Description ...................................................................................................................................66 5.1.11.2 Technical Specification ................................................................................................................66 5.2 UHF 2 AIR INTERFACE (60-055902) ..........................................................................................................67 5.2.1 Bandpass Filter (02-013401) See section 5.1.1........................................................................................67 5.2.2 4 Port Tx Hybrid Combiner (05-003019) ................................................................................................67 5.2.2.1 Description .......................................................................................................................................67 5.2.2.2 Technical Specification ....................................................................................................................67 5.2.3 Four Way Low Power Splitter (05-003401) See section 5.1.2 ................................................................68 5.2.4 ¼Watt 0- -30dB Switched Attenuator (10-000701) See section 5.1.3.....................................................68 5.2.5 Low Noise Amplifiers (11-007302 & 11-007402) See section 5.1.4 ......................................................68 5.2.6 3 Stage Amplifier Alarm Boards (12-002201) See section 5.1.6.............................................................68 5.2.7 20Watt Power Amplifier (12-004201) .....................................................................................................68 PBL UHF1/1A 1 & 2 Air Interface Maintenance Handbook H/book Number:-60-055900HBKM Issue No:-2 Date:-20/10/2003 Page:-3 of 85 5.2.7.1 Description .......................................................................................................................................68 5.2.7.2 Technical Specification ....................................................................................................................68 5.2.7.3 Drg. Nō. 12-004201, PA General Assembly....................................................................................69 5.2.7.4 Drg. Nō. 12-004270, PA Circuit Diagram .......................................................................................70 5.2.7.5 Drg. Nō. 12-004270C1, PA Parts List(1).........................................................................................71 5.2.7.6 Drg. Nō. 12-004270C2, PA Parts List(2).........................................................................................72 5.2.7.7 Drg. Nō. 12-003670, PA to Alarm Wiring Details ..........................................................................73 5.2.8 DC/DC Converter, 24V in, 12V 8A out (13-003011) See section 5.1.7..................................................74 5.2.9 Chan. Selec. & Chan. Contr. Mdls (17-003012 & 17-002101) See section 5.1.8 ...................................74 5.2.10 21MHz IF Filter Board (17-002502)....................................................................................................74 5.2.10.1 Description ...................................................................................................................................74 5.2.11 Single & Dual 24Volt Relay Boards (20-001602 & 80-008902) See section 5.1.9.............................74 5.2.12 SMA Coaxial Termination (93-930003) See section 5.1.10 ................................................................74 5.2.13 24V 400W Flat-Pack Power Supply (96-300011) See section 5.1.11 .................................................74 5.2.14 JWS75-15/A PSU (96-300045)............................................................................................................74 5.2.14.1 Description ...................................................................................................................................74 5.2.14.2 Technical Specification ................................................................................................................74 5.2.15 Single Mode Optical Coupler (98-100001)..........................................................................................75 5.2.15.1 Description ...................................................................................................................................75 5.2.16. Fibre Optic Receiver & Transmitter (98-200003 & 98-300003) .........................................................75 5.2.16.1 Description ...................................................................................................................................75 5.2.16.2 Technical Specification ................................................................................................................76 5.3 UHF1A 60-055903 470MHZ 3 CHANNEL BDA.........................................................................................77 6. 6.1 6.2 6.3 6.4 6.5 6.6 7. INSTALLATION............................................................................................................................ 78 INITIAL INSTALLATION RECORD ................................................................................................................78 GENERAL .....................................................................................................................................................78 ELECTRICAL CONNECTIONS .......................................................................................................................78 OPTICAL CONNECTIONS..............................................................................................................................78 RF CONNECTIONS .......................................................................................................................................79 COMMISSIONING..........................................................................................................................................79 MAINTENANCE............................................................................................................................ 80 7.1 GENERAL PROCEDURES ..............................................................................................................................80 7.1.1 Fault Finding ............................................................................................................................................80 7.1.2 Downlink..................................................................................................................................................81 7.1.3 Uplink.......................................................................................................................................................81 7.1.4 Fault repair ...............................................................................................................................................81 7.1.5 Checking service ......................................................................................................................................82 7.1.6 Service Support ........................................................................................................................................82 7.2 TOOLS & TEST EQUIPMENT........................................................................................................................82 7.3 CARE OF MODULES .....................................................................................................................................83 7.3.1 General Comments ...................................................................................................................................83 7.3.2 Module Removal (LNA’s, general procedure): .......................................................................................83 7.3.3 Module Replacement (general): ...............................................................................................................83 7.3.4 Power Amplifiers .....................................................................................................................................83 7.3.5 Low Power Amplifier Replacement.........................................................................................................84 7.3.6 Module Transportation:............................................................................................................................84 APPENDIX A INITIAL EQUIPMENT SET-UP CALCULATIONS............................................... 85 PBL UHF1/1A 1 & 2 Air Interface Maintenance Handbook H/book Number:-60-055900HBKM Issue No:-2 Date:-20/10/2003 Page:-4 of 85 AMENDMENT LIST RECORD SHEET Issue Nō. Date 06/02/03 02/10/2003 Incorporated by CMH Page No.’s Amended CMH Reason for new issue 1st Issue New UHF1A added Document Ref:-60-055900HBKM PBL UHF1/1A 1 & 2 Air Interface Maintenance Handbook H/book Number:-60-055900HBKM Issue No:-2 Date:-20/10/2003 Page:-5 of 85 INTRODUCTION Scope This handbook is for use solely with the equipment identified by the AFL Part Number shown on the front cover. It is not to be used with any other equipment unless specifically authorised by Aerial Facilities Limited. This is a controlled release document and, as such, becomes a part of Aerial Facilities’ Total Quality Management System. Alterations and modification may therefore only be performed by Aerial Facilities Ltd. Purpose The purpose of this handbook is to provide the user/maintainer with sufficient information to service and repair the equipment to the level agreed. Maintenance and adjustments to any deeper level must be performed by AFL, normally at the company’s repair facility in Chesham, England. This handbook has been prepared in accordance with BS 4884, and AFL’s Quality procedures, which maintain the company’s registration to ISO 9001: 1994 and to the R&TTE Directive of the European Parliament. Copies of the relevant certificates and the company Quality Manual can be supplied on application to the Quality Manager. This document fulfils the relevant requirements of Article 6 of the R&TTE Directive. Limitation of Information Notice This manual is written for the use of technically competent operators/service persons. No liability is accepted by AFL for use or misuse of this manual, the information contained therein, or the consequences of any actions resulting from the use of the said information, including, but not limited to, descriptive, procedural, typographical, arithmetical, or listing errors. Furthermore, AFL does not warrant the absolute accuracy of the information contained within this manual, or it’s completeness, fitness for purpose, or scope. AFL has a policy of continuous product development and enhancement, and as such, reserves the right to amend, alter, update and generally change the contents, appearance and pertinence of this document without notice. All AFL products carry a twelve month warranty from date of shipment. The warranty is expressly on a return to base repair or exchange basis and the warranty cover does not extend to on-site repair or complete unit exchange. PBL UHF1/1A 1 & 2 Air Interface Maintenance Handbook H/book Number:-60-055900HBKM Issue No:-2 Date:-20/10/2003 Page:-6 of 85 Glossary of Terms Repeater or Cell Enhancer Band Selective Repeater Channel Selective Repeater BTS C/NR Downlink (D.L.) Uplink (U.L.) EMC GND DC AC ID OIP3 LED M.S. N/A N/C NF RF Rx Tx S/N A Radio Frequency (RF) amplifier which can simultaneously amplify and re-broadcast Mobile Station (MS) and Base Transceiver Station (BTS) signals. A Cell Enhancer designed for operation on a range of channels within a specified frequency band. A Cell Enhancer, designed for operation on specified channel(s) within a specified frequency band. Channel frequencies may be factory set or on-site programmable. Base Transceiver Station Carrier-to-Noise Ratio RF signals transmitted from the BTS and to the MS RF signals transmitted from the MS to the BTS Electromagnetic Compatibility Ground Direct Current Alternating Current Identification Number Output Third Order Intercept Point = RFout +(C/I)/2 Light Emitting Diode Mobile Station Not Applicable No Connection Noise Figure Radio Frequency Receiver Transmitter Serial Number PBL UHF1/1A 1 & 2 Air Interface Maintenance Handbook H/book Number:-60-055900HBKM Issue No:-2 Date:-20/10/2003 Page:-7 of 85 AFL Drawing Symbol Keys PBL UHF1/1A 1 & 2 Air Interface Maintenance Handbook H/book Number:-60-055900HBKM Issue No:-2 Date:-20/10/2003 Page:-8 of 85 1. SAFETY CONSIDERATIONS 1.1 Electric Shock Hazard Electrical shocks due to faulty mains driven power supplies. Whilst ever potentially present in any electrical equipment, such a condition would be minimised by quality installation practice and thorough testing at: a) Original assembly. b) Commissioning. c) Regular intervals, thereafter. All test equipment to be in good working order prior to its use. High current power supplies can be dangerous because of the possibility of substantial arcing. Always switch off during disconnection and reconnection. 1.2 RF Radiation Hazard “CAUTION: This equipment is approved for antennas mounted on fixed outdoor permanent structures. A minimum separation distance of 2 metres must be maintained between the radiating elements and any nearby persons. A maximum antenna gain of 21 dBi may be used. Operating this equipment without regard to these restrictions will result in RF exposure levels above the limits allowed by FCC rules.” This equipment complies with part 90 of the FCC rules. Any changes or modifications not expressly approved by the manufacturer could void the user’s authority to operate the equipment. Antenna positions should be chosen to comply with requirements (both local & statutory) regarding exposure of personnel to RF radiation. When connected to an antenna, the unit is capable of producing RF field strengths, which may exceed guideline safe values especially if used with antennas having appreciable gain. In this regard the use of directional antennas with backscreens and a strict site rule that personnel must remain behind the screen while the RF power is on, is strongly recommended. RF radiation, (especially at UHF frequencies) arising from transmitter outputs connected to AFL’s equipment, must be considered a safety hazard. This condition might only occur in the event of cable disconnection, or because a ‘spare’ output has been left unterminated. Either of these conditions would impair the system’s efficiency. No investigation should be carried out until all RF power sources have been removed. This would always be a wise precaution, despite the severe mismatch between the impedance of an N type connector at 50Ω, and that of free space at 377Ω, which would severely mitigate against the efficient radiation of RF power. Radio frequency burns could also be a hazard, if any RF power carrying components were to be carelessly touched! Where the equipment is used near power lines, or in association with temporary masts not having lightning protection, the use of a safety earth connected to the case-earthing bolt is strongly advised. PBL UHF1/1A 1 & 2 Air Interface Maintenance Handbook H/book Number:-60-055900HBKM Issue No:-2 Date:-20/10/2003 Page:-9 of 85 1.3 Chemical Hazard Beryllium Oxide, also known as Beryllium Monoxide, or Thermalox™, is sometimes used in devices within equipment produced by Aerial Facilities Ltd. Beryllium oxide dust can be toxic if inhaled, leading to chronic respiratory problems. It is harmless if ingested or by contact. Products that contain beryllium are load terminations (dummy loads) and some power amplifiers. These products can be identified by a yellow and black “skull and crossbones” danger symbol (shown above). They are marked as hazardous in line with international regulations, but pose no threat under normal circumstances. Only if a component containing beryllium oxide has suffered catastrophic failure, or exploded, will there be any danger of the formation of dust. Any dust that has been created will be contained within the equipment module as long as the module remains sealed. For this reason, any module carrying the yellow and black danger sign should not be opened. If the equipment is suspected of failure, or is at the end of its life-cycle, it must be returned to Aerial Facilities Ltd for disposal. To return such equipment, please contact the Quality Department, who will give you a Returned Materials Authorisation (RMA) number. Please quote this number on the packing documents, and on all correspondence relating to the shipment. PolyTetraFluoroEthylene, (P.T.F.E.) and P.T.F.E. Composite Materials Many modules/components in AFL equipment contain P.T.F.E. as part of the RF insulation barrier. This material should never be heated to the point where smoke or fumes are evolved. Any person feeling drowsy after coming into contact with P.T.F.E. especially dust or fumes should seek medical attention. PBL UHF1/1A 1 & 2 Air Interface Maintenance Handbook H/book Number:-60-055900HBKM Issue No:-2 Date:-20/10/2003 Page:-10 of 85 1.4 Laser safety General good working practices adapted from EN60825-2: 1994 “Do not stare with unprotected eyes or with any unapproved optical device at the fibre ends or connector faces or point them at other people.” “Use only approved filtered or attenuating viewing aids.” “Any single or multiple fibre end or ends found not to be terminated (for example, matched, spliced) shall be individually or collectively covered when not being worked on. They shall not be readily visible and sharp ends shall not be exposed.” “When using test cords, the optical power source shall be the last connected and the first disconnected.” “Use only approved methods for cleaning and preparing optical fibres and optical connectors.” Always keep optical connectors covered to avoid physical damage Do not allow any dirt/foreign material ingress on the optical connector bulkheads. The optical fibre jumper cable maximum bend radius is 3cm, any smaller radii may result in optical cable breakage or excessive transmission losses. Caution: Do not get them wet, the FO units are NOT weather proof. 1.5 Emergency Contact Numbers The AFL Quality Department can be contacted on: Telephone Fax e-mail +44 (0)1494 777000 +44 (0)1494 777002 qa@aerial.co.uk PBL UHF1/1A 1 & 2 Air Interface Maintenance Handbook H/book Number:-60-055900HBKM Issue No:-2 Date:-20/10/2003 Page:-11 of 85 2. OVERVIEW/SYSTEM DESCRIPTION The AFL Off air Amplifiers for the Pasadena Blue line project are 2 way on-band RF amplifiers. Their application is as an interface between the donor radio sites and the Fibre optic receivers and transmitters which will extend coverage to the locations via the fibre optic link. There are two units one designated for the ‘UHF1’ frequencies the other for the ‘UHF2’ frequencies. Each unit is housed in an environmentally protected IP65 steel wall-mount case. Handles are provided for carrying the unit and the door is fitted with locks. The unit interfaces with ‘N’ type female connectors for RF connections and heavy duty connectors for routing of AC power supply input and alarm output wiring. Cable glands are provided for routing of the Fibre optic cable in to the unit. To provide adequate selectivity in the Downlink and Uplink paths, combline design bandpass quadplexers and duplexers are used at the air interface ports. In addition each channel to be passed is selected by a 15kHz or 25KHz Channel module which provides a high level of rejection at adjacent channels. To provide the required gain to reach the required signal levels, low-noise amplifiers (LNA’s) are used in each path, these being followed by power amplifier modules in the uplink to provide the required intermodulation performance. Gain adjustment is available locally using switched attenuators. Note that “Downlink” refers to the RF path from the base station (donor site) to the FO transmitter and that “Uplink” refers to the RF path from the FO receiver to the remote base station. PBL UHF1/1A 1 & 2 Air Interface Maintenance Handbook H/book Number:-60-055900HBKM Issue No:-2 Date:-20/10/2003 Page:-12 of 85 3. SPECIFICATIONS Parts Lists 3.1 3.1.1 UHF1/1A & UHF2 Location ONE 60-055900 Parts List AFL Part Nō. Part Description 60-055901 PBL F/O AIR INTERFACE LOC1 UHF1 60-055902 PBL F/O AIR INTERFACE LOC1 UHF2 3.1.1.1 02-013401 05-002603 05-003401 10-000701 11-006102 11-007302 11-007402 12-001801 12-002201 12-002220 12-002826 13-003011 17-000126 17-001523 17-002020 17-002021 17-002101 17-002103 17-003012 17-003022 17-003023 17-003024 17-003025 17-003028 17-003029 17-009723 17-009727 20-001602 80-008902 80-032320 80-032322 90-010021 Qty. F/O Air Interface 60-055901 Location ONE-UHF1 Parts List 6P CL FILTER (0.5 min BW) LARGE SMA ASSY UHF 3dB SPLITTER SMA 4 WAY SPLITTER LOW POWER 1/4W0-30dB SWITCHED ATTENUATOR LNA 380-500MHz 1W WITH RELAY LNA. 380-500MHz 20dB (C/W RELAY) GA LNA. 380-500MHz 30dB (C/W RELAY) GA UHF PWR AMP.450MHz 5W SMA ALARMS 3 STAGE AMPLIFIER ALARM BOARD 3 STAGE ALARM PCB COVER ALARM BOARD ACRYLIC LENS DC/DC CONVERTER 24-12V 8A PCB SUB-ASS CELL ENHANCER LABEL 6 DIGIT GREY C.E. HEATSINK BLANKING PLATE CASE 620 x 620 x 250 SCHROFF CUSTOM BASE PLATE 585 x 570mm FOR 17-002020 CHANNEL CONTROL MODULE 26WAY RIBBON CABLE LEAD CHAN MOD 450MHz, 15kHz B/W MODULE PATTERNED LEAVE SUBRACK SIDE PANEL SUBRACK REAR BRACKET BOTTOM MODULE GUIDE MODULE SQUARE LEAVE TOP MODULE GUIDE EQUIP. MTG PLATE No.4 EQUIP. MTG PLATE No.8 24V RELAY BOARD 24V RELAY PCB ASSEMBLY POWER AMP HEATSINK 10W 900MHz POWER SUPPLY HEATSINK 10W RF CABLE SUPFLEX SMA R/A MALE 100mm 15 PBL UHF1/1A 1 & 2 Air Interface Maintenance Handbook H/book Number:-60-055900HBKM Issue No:-2 Date:-20/10/2003 Page:-13 of 85 90-010022 90-010026 90-010027 90-010028 90-010130 90-010131 90-010134 90-010135 91-030002 91-500011 91-500015 91-500016 91-510010 91-510013 91-510014 91-600005 91-600007 91-600014 91-620002 91-640003 91-700017 92-280033 92-400017 93-540035 93-930003 96-300011 96-500003 96-500005 96-700002 96-700005 96-900018 96-920011 96-920012 97-000002 97-300010 97-400010 97-600001 97-600002 97-900004 RF CABLE SUPFLEX SMA R/A MALE 200mm RF CABLE HIFLEX SMA R/A MALE 150mm RF CABLE HIFLEX SMA R/A MALE 250mm RF CABLE HIFLEX SMA R/A MALE 350mm RF CABLE SMA R/A-N PANEL JACK 100mm RF CABLE SMA R/A-N PANEL JACK 200mm RF CABLE SMA R/A-N PANEL JACK 400mm RF CABLE SMA R/A-N PANEL JACK 500mm N ADAPTOR PANEL FEMALE:FEMALE PWR 3POLE PNL PLUG SEALED IP68 PWR CON CAP SEALED with INT. THREAD PWR 6POLE PNL PLUG SEALED IP68 PWR 3POLE FREE SOC.SEALED IP68 PWR CON CAP SEALED with Ext. THREAD PWR 6POLE FREE SOC.SEALED IP68 'D' 9 WAY SOCKET S/B TERM 'D' 9 WAY BLACK SHELL 'D' 9 WAY SOCKET S/B (NON FILTERED) 'D' 25 WAY SOCKET/IDC TERMS MISC 26 WAY RIBBON CABLE SOCK. ICD 15 WAY 0.1' CONNECTOR Captive Screw GASKET FOR N TYPE CONNECTOR 1K3 0.25W 1% RES MRS25 M:F SMA COAX TERMINATION [RADIAL] 24 V 400 W FLATPACK PWR SUPPLY AC FILTER 110V 5A DC INPUT FILTERS LED.GREEN 5mm SEALED IP66 LED.RED 5mm SEALED IP66 AC TRIP SWITCH (5 AMP M.C.B.) PROXIMITY SWITCH PROXIMITY SWITCH MAGNET BLACK MODULE CAGE RUNNER SUPPLY I/P COVERS BLACK PLASTIC HANDLE 37311 SUBRACK FRONT HORIZ SUBRACK M2.5 STD TAP RUBBER FOOT FOR CELL ENHANCERS 12 12 PBL UHF1/1A 1 & 2 Air Interface Maintenance Handbook H/book Number:-60-055900HBKM Issue No:-2 Date:-20/10/2003 Page:-14 of 85 3.1.1.2 F/O Air Interface 60-055902 Location ONE, UHF2 Parts List AFL Part Nō. 02-013401 05-002603 05-003019 05-003401 10-000701 11-007302 11-007402 12-002201 12-002220 12-002826 12-004201 13-003011 17-000126 17-002020 17-002021 17-002101 17-002103 17-002502 17-003012 17-003022 17-003023 17-003024 17-003025 17-003028 17-003029 17-009723 17-009726 20-001602 80-008902 80-031820 80-032320 80-032322 90-010021 90-010022 90-010024 90-010025 90-010026 90-010027 90-010028 90-010030 90-010131 90-010135 Part Description Qty. 6P CL FLTR(0.5 min BW) LARGE SMA ASSY UHF 3dB SPLITTER SMA 4 PORT THC 3dB 450MHz SMA TYPE 4 WAY SPLITTER LOW POWER 1/4W0-30dB SWITCHED ATTENUATOR LNA. 380-500MHz 20dB (C/W RELAY) GA LNA. 380-500MHz 30dB (C/W RELAY) GA 3 STAGE AMPLIFIER ALARM BOARD 3 STAGE ALARM PCB COVER ALARM BOARD ACRYLIC LENS PWR AMP.450MHz 20W version CLASS A DC/DC CONVERTER 24-12V 8A PCB SUB-ASS CELL ENHANCER LABEL 6 DIGIT CASE 620 x 620 x 250 SCHROFF CUSTOM BASE PLATE 585 x 570mm FOR 17-002020 CHANNEL CONTROL MODULE 26WAY RIBBON CABLE LEAD IF FILTER BOARD 21.4MHz 30kHz CHAN MOD 450MHz, 15kHz B/W MODULE PATTERNED LEAVE SUBRACK SIDE PANEL SUBRACK REAR BRACKET BOTTOM MODULE GUIDE MODULE SQUARE LEAVE TOP MODULE GUIDE EQUIP. MTG PLATE No.4 EQUIP. MTG PLATE No.7 24V RELAY BOARD 24V RELAY PCB ASSEMBLY POWER AMP HEATSINK 20W 900MHz POWER AMP HEATSINK 10W 900MHz POWER SUPPLY HEATSINK 10W RF CABLE SUPFLEX SMA R/A MALE 100mm 20 RF CABLE SUPFLEX SMA R/A MALE 200mm RF CABLE SUPFLEX SMA R/A MALE 400mm RF CABLE SUPFLEX SMA R/A MALE 500mm RF CABLE HIFLEX SMA R/A MALE 150mm RF CABLE HIFLEX SMA R/A MALE 250mm RF CABLE HIFLEX SMA R/A MALE 350mm RF CABLE HIFLEX SMA R/A MALE 600mm RF CABLE SMA R/A-N PANEL JACK 200mm RF CABLE SMA R/A-N PANEL JACK 500mm PBL UHF1/1A 1 & 2 Air Interface Maintenance Handbook H/book Number:-60-055900HBKM Issue No:-2 Date:-20/10/2003 Page:-15 of 85 91-030002 91-500011 91-500015 91-500016 91-510010 91-510013 91-510014 91-600005 91-600007 91-600014 91-620002 91-640003 91-700017 91-800014 91-800019 92-120009 92-280033 92-400017 93-540035 93-930003 96-300011 96-300045 96-500003 96-500005 96-700002 96-700005 96-900018 96-920011 96-920012 97-000002 97-300010 97-400010 97-600001 97-600002 97-900004 98-100001 98-200003 98-300003 98-500004 N ADAPTOR PANEL FEMALE:FEMALE PWR 3POLE PNL PLUG SEALED IP68 PWR CON CAP SEALED with INT. THREAD PWR 6POLE PNL PLUG SEALED IP68 PWR 3POLE FREE SOC.SEALED IP68 PWR CON CAP SEALED with Ext. THREAD PWR 6POLE FREE SOC.SEALED IP68 'D' 9 WAY SOCKET S/B TERM 'D' 9 WAY BLACK SHELL 'D' 9 WAY SOCKET S/B (NON FILTERED) 'D' 25 WAY SOCKET/IDC TERMS MISC 26 WAY RIBBON CABLE SOCK. ICD 15 WAY 0.1' CONNECTOR 3 WAY TERMINAL BLOCK OPTICAL BARREL ADAPT M20 IP68 CABLE GLAND Captive Screw GASKET FOR N TYPE CONNECTOR 1K3 0.25W 1% RES MRS25 M:F SMA COAX TERMINATION [RADIAL] 24 V 400 W FLATPACK PWR SUPPLY JWS75-15/A PSU (COUTANT LAMBDA) AC FILTER 110V 5A DC INPUT FILTERS LED.GREEN 5mm SEALED IP66 LED.RED 5mm SEALED IP66 AC TRIP SWITCH (5 AMP M.C.B.) PROXIMITY SWITCH PROXIMITY SWITCH MAGNET BLACK MODULE CAGE RUNNER SUPPLY I/P COVERS BLACK PLASTIC HANDLE 37311 SUBRACK FRONT HORIZ SUBRACK M2.5 STD TAP RUBBER FOOT FOR CELL ENHANCERS 1 x 2 SINGLE MODE OPTICAL COUPLR 1310 FIBRE OPTIC Rx 6325 1310nm <2.2GHz FIBRE OPTIC Tx 6325 1310nm <2.2GHz FC/APC-FC/APC FIBREOPTIC CABLE 0.5M 16 16 PBL UHF1/1A 1 & 2 Air Interface Maintenance Handbook H/book Number:-60-055900HBKM Issue No:-2 Date:-20/10/2003 Page:-16 of 85 3.1.1.3 F/O Air Interface 60-055903 Location ONE, UHF1A Parts List AFL Part Nō. 02-013401 05-002603 05-003401 10-000701 11-007402 12-002201 12-002220 12-016301 13-003011 17-000126 17-002020 17-003012 17-003022 17-003023 17-003024 17-003025 17-003028 17-003029 20-001602 80-031820 80-032320 91-030002 91-500011 91-500015 91-500016 91-600005 91-600007 93-540035 93-930003 96-300011 96-500005 96-700002 96-700005 96-920011 96-920012 97-400010 97-900004 Part Description 6P CL FILTER (0.5 min BW)LARGE SMA ASSY UHF 3dB SPLITTER SMA 4 WAY SPLITTER LOW POWER 1/4W0-30dB SWITCHED ATTENUATOR LNA. 380-500MHz 30dB (C/W RELAY) GA 3 STAGE AMPLIFIER ALARM BOARD 3 STAGE ALARM PCB COVER PA 380-470MHz 20W CLASS A DC/DC CONVERTER 24-12V 8A PCB SUB-ASS CELL ENHANCER LABEL 6 DIGIT CASE 620 x 620 x 250 SCHROFF CUSTOM CHAN MOD 450MHz, 15kHz (8p) BW MODULE PATTERNED LEAVE SUBRACK SIDE PANEL SUBRACK REAR BRACKET BOTTOM MODULE GUIDE MODULE SQUARE LEAVE TOP MODULE GUIDE 24V RELAY BOARD 20W PA HEATSINK (NEEDS 17-000526) 10W PA HEATSINK (NEEDS 17-000526) N ADAPTOR PANEL FEMALE:FEMALE PWR 3POLE PNL PLUG SEALED IP68 PWR CON CAP SEALED with INT. THREAD PWR 6POLE PNL PLUG SEALED IP68 'D' 9 WAY SOCKET S/B TERM 'D' 9 WAY BLACK SHELL 1K3 0.25W 1% RES MRS25 M:F SMA COAX TERMINATION [RADIAL] 24 V 400 W FLATPACK PWR SUPPLY DC INPUT FILTERS LED.GREEN 5mm SEALED IP66 LED.RED 5mm SEALED IP66 PROXIMITY SWITCH PROXIMITY SWITCH MAGNET BLACK PLASTIC HANDLE 37311 RUBBER FOOT FOR CELL ENHANCERS Qty. 32 32 16 32 16 PBL UHF1/1A 1 & 2 Air Interface Maintenance Handbook H/book Number:-60-055900HBKM Issue No:-2 Date:-20/10/2003 Page:-17 of 85 3.2 3.2.1 Technical Specifications UHF ONE to Tunnels 1 & 2 Technical Specification Frequency Range: Band Width Nō. of Paths Downlink Gain Uplink Gain RF Connector RF Impedance VSWR Gain Adjustment Downlink PA Uplink PA Duplexer UP/DN Isolation Passband Ripple Noise Figure Noise Figure In-Band Spurious Out-band Spurious up to 3GHz: Downlink Channels: Uplink Channels: 470.2125MHz 473.2125MHz 470.2625MHz 473.2625MHz 482.2375MHz 485.2375MHz Downlink :15kHz Uplink : 25kHz 82 dB min 70 dB min N type female 50Ω Better than 1.5:1 0 to 30 in 2dB steps 470.2125MHz, 470.2125MHz: 5WClass A Linear PA 482.2375MHz :20W Class A Linear PA 485.2375MHz : 1W Class A Linear 473.2625MHz, 473.2125MHz : 5W Class A Linear >80 dB <±1.5 dB Downlink <7 dB at maximum gain Uplink <18 dB at maximum gain Better than –13dBm downlink Better than –13dBm uplink (measure with 30KHz BW & max gain setting) Better than –90dBc PBL UHF1/1A 1 & 2 Air Interface Maintenance Handbook H/book Number:-60-055900HBKM Issue No:-2 Date:-20/10/2003 Page:-18 of 85 3.2.2 UHF1A Technical Specification Downlink Channels: Uplink Channels: 470.0875MHz 473.0875MHz Frequency Range: 470.1375MHz 473.1375MHz 470.3625MHz 473.3625MHz Downlink : 15kHz Band Width Uplink : 15kHz Nō. of Paths Nō. of RF Ports Downlink Gain 51 dB min Uplink Gain 40 dB min RF Connector N type female RF Impedance 50Ω VSWR Better than 1.5:1 Gain Adjustment 0 to 30 in 2dB steps Downlink Power 3 channels at -11dBm Uplink Power 3 channels at +20dBm Uplink PA 10Watts Class A Linear Passband Ripple <±1.5dB Duplexer UP/DN Isolation >80 dB Passband Ripple <±1.5 dB Noise Figure Downlink <5 dB at maximum gain Noise Figure Uplink <18 dB at maximum gain In-Band Spurious Better than –55dBm downlink Better than –55dBm uplink (measure with 30KHz BW & max gain setting) Out-band Spurious up to Better than –90dBc 3GHz: PBL UHF1/1A 1 & 2 Air Interface Maintenance Handbook H/book Number:-60-055900HBKM Issue No:-2 Date:-20/10/2003 Page:-19 of 85 3.2.3 UHF ONE to Location TWO Technical Specification Frequency Range: Band Width: No. of Paths Downlink Gain Uplink Gain RF Connector RF Impedance VSWR Gain Adjustment Downlink PA Uplink PA Duplexer UP/DN Isolation Passband Ripple Noise Figure Noise Figure In-Band Spurious Out-band Spurious up to 3GHz Downlink Channels: Uplink Channels: 470.2125MHz 473.2125MHz 470.2625MHz 473.2625MHz 482.2375MHz 485.2375MHz Downlink :15kHz Uplink : 25kHz 82 dB min 80 dB min N type female 50Ω Better than 1.5:1 0 to 30dB in 2dB steps 470.2125MHz, 470.2125MHz: 5WClass A Linear PA 482.2375MHz :20W Class A Linear PA 485.2375MHz : 1W Class A Linear 473.2625MHz, 473.2125MHz : 5W Class A Linear >80 dB <±1.5 dB Downlink <7dB at maximum gain Uplink <12dB Better than –13dBm downlink Better than –13dBm uplink (measure with 30KHz BW with max gain setting) Better than –90dBc PBL UHF1/1A 1 & 2 Air Interface Maintenance Handbook H/book Number:-60-055900HBKM Issue No:-2 Date:-20/10/2003 Page:-20 of 85 3.2.4 UHF TWO to Tunnels 1 & 2 Technical Specification Frequency Range: Band Width: Nō. of Paths: RF Connector: RF Impedance: VSWR: Downlink Gain: Uplink Gain: Gain Adjustment: Downlink PA: Uplink PA: Duplexer UP/DN Isolation: Passband Ripple: Noise Figure: Noise Figure: In-Band Spurious: Out-band Spurious up to 3GHz: Downlink Channels: Uplink Channels: 483.0625MHz 486.0625MHz 483.2875MHz 486.2875MHz 483.3125MHz 486.3125MHz 483.5625MHz 486.5625MHz Downlink :15kHz Uplink : 25kHz ,486.0625MHz, 486.5625MHz 15kHz ,486.2875MHz, 486.3125MHz N type female 50Ω Better than 1.5:1 90 dB min 68 dB min 0 to 30 in 2dB steps 20W Class A Linear 20W Class A Linear >80 dB <±1.5 dB Downlink <5 dB at maximum gain Uplink <12dB at maximum gain Better than –13dBm downlink Better than –13dBm uplink (measure with 30KHz BW with max gain setting) Better than –90dBc PBL UHF1/1A 1 & 2 Air Interface Maintenance Handbook H/book Number:-60-055900HBKM Issue No:-2 Date:-20/10/2003 Page:-21 of 85 3.2.5 UHF TWO to Location TWO Technical Specification Frequency Range: Band Width: Nō. of Paths: RF Connector: RF Impedance: VSWR: Downlink Gain: Uplink Gain: Gain Adjustment: Downlink PA: Uplink PA: Duplexer UP/DN Isolation: Passband Ripple: Noise Figure: Noise Figure: In-Band Spurious: Out-band Spurious up to 3GHz: Downlink Channels: Uplink Channels: 483.0625MHz 486.0625MHz 483.2875MHz 486.2875MHz 483.3125MHz 486.3125MHz 483.5625MHz 486.5625MHz Downlink :15kHz Uplink : 25kHz ,486.0625MHz, 486.5625MHz 15kHz ,486.2875MHz, 486.3125MHz N type female 50Ω Better than 1.5:1 90 dB min 78 dB min 0 to 30 in 2dB steps 20W Class A Linear 20W Class A Linear >80 dB <±1.5 dB Downlink <5 dB at maximum gain Uplink <12 dB at maximum gain Better than –13dBm downlink Better than –13dBm uplink (measure with 30KHz BW & max gain setting) Better than –90dBc PBL UHF1/1A 1 & 2 Air Interface Maintenance Handbook H/book Number:-60-055900HBKM Issue No:-2 Date:-20/10/2003 Page:-22 of 85 3.2.6 800MHz Bi-directional Amplifier to Location TWO Technical Specification Frequency Range: Band Width: No. of Paths: No. of RF Ports: No. of Fibre Connections: RF Connector: RF Impedance: VSWR: Downlink Gain: Uplink Gain: Gain Adjustment: Downlink PA: Downlink Power: Uplink PA: Uplink Power: Duplexer UP/DN Isolation: Passband Ripple: Noise Figure: In-Band Spurious: MTBF: Supply Input Voltage: Alarms Fitted: Downlink Channels: Uplink Channels: 857.9375MHz 812.9375MHz 859.7625MHz 814.7625MHz Downlink :15kHz Uplink : 25kHz N/A N type female 50Ω Better than 1.5:1 78 dB min 80 dB min 0 to 30 in 2dB steps 5W Class A Linear 2 Carriers at +18dBm 5W Class A Linear 2 Carriers at +18dBm >80 dB <±1.5 dB Uplink <6 dB at maximum gain Downlink <5 dB at maximum gain Better than –13dBm downlink Better than –13dBm uplink (measure with 30KHz BW with max gain setting) >50,000 hours 110V AC Alarm:- Volts free contacts Alarm indicator:- Red LED Power Indicator:-Green LED Door Intrusion:- Magnetic proximity switch PBL UHF1/1A 1 & 2 Air Interface Maintenance Handbook H/book Number:-60-055900HBKM Issue No:-2 Date:-20/10/2003 Page:-23 of 85 3.3 Mechanical Specification (UHF1/1A & UHF2 Wall Cases) Height: 620mm Width: Case size 620mm Depth: 250mm (excluding heatsinks, connectors, handles and feet) Fixings: 4 holes on 670(w) x 557(h)mm operational: -10°C to +55°C Temperature Range storage: -40°C to +70°C Weight: 70kg (approximately) RF Connectors: N type female Environmental Protection: IP65 (with door closed and all ports terminated) Case: To RAL 7032 Heatsinks: Matt black (where fitted) Finish: Handles: Black plastic Unit supplied with suitable supply input leads with Supply Cable: connector and appropriate length of cable PBL UHF1/1A 1 & 2 Air Interface Maintenance Handbook H/book Number:-60-055900HBKM Issue No:-2 Date:-20/10/2003 Page:-24 of 85 H/book Number:-60-055900HBKM Issue No:-2 Date:-20/10/2003 CHKD PBL UHF1/1A 1 & 2 Air Interface Maintenance Handbook Page:-25 of 85 GD APPD 15/10/02 DATE ALL DIMENSIONS ARE IN mm UNLESS OTHERWISE STATED PB DBS DRAWN 115V AC INPUT M6 EARTH STUD 620 [2'-0.4"] 555 [1'-9.9"] ALARM NO DECIMAL PLACE ± 1mm ONE DECIMAL PLACE ± 0.3mm TWO DECIMAL PLACES ± 0.1mm TOLERANCES SCALE - N A eri al Faci l i t i es Li mi ted E ngl and P roduct ref : UHF 1 1:5 670 [2'-2.4"] CE - 620 [2'-0.4"] 700 [2'-3.6"] THIS IS A PROPRIETARY DESIGN OF AERIAL FACILITIES LTD. REPRODUCTION OR USE OF THIS DESIGN BY OTHERS IS PERMISSIBLE ONLY IF EXPRESSLY AUTHORISED IN WRITING BY AERIAL FACILITIES LTD. PSU CA UTION Heavy DA NGE R Hi gh vol tage THIRD ANGLE PROJECTION ALARMS Tel : 01494 777000 Fax : 01494 777002 DOWNLINK OUTPUT UHF 1 Aerial Facilities Limited England CUSTOMER TITLE 250 [9.9"] DRAWING.No OUTLINE DRAWING 60-055990 PASADENA BLUE LINE. LOCATION 1.UHF1 ISSUE DATE 15/10/02 PRODUCTION ISSUE 1A DESCRIPTION 21/10/02 DECIMAL EQUIV'S 1B No 30/10/02 ECN2746 MATERIAL: MILD STEEL FINISH: PAINTED TO RAL 9017 SEMIGLOSS TRAFFIC BLACK WALL FIXINGS: M8 (5/16") RF CONNECTORS: N TYPE FEMALE ENVIRONMENTAL CLASS: IP65 DOWNLINK INPUT/UPLINK OUTPUT UHF 1 (ANTENNA) 2A UPLINK INPUT UHF 1 709 [2'-3.9"] BY DBS DBS DBS 4. SYSTEM DRAWINGS 4.1 Drg. Nō. 60-055990, Location ONE, UHF1/1A Case Outline Drawing H/book Number:-60-055900HBKM Issue No:-2 Date:-20/10/2003 CHKD PBL UHF1/1A 1 & 2 Air Interface Maintenance Handbook Page:-26 of 85 APPD GD 01/07/03 DATE ALL DIMENSIONS ARE IN mm UNLESS OTHERWISE STATED PB MNR DRAWN 115V AC INPUT M6 EARTH STUD 620 [2'-0.4"] 555 [1'-9.9"] AL ARM NO DECIMAL PLACE ± 1mm ONE DECIMAL PLACE ± 0.3mm TWO DECIMAL PLACES ± 0.1mm TOLERANCES SCALE - N A eri al Faci l i t i es Li mi t ed E ngl and P roduct r ef : UHF 1A 1:5 670 [2'-2.4"] CE - 620 [2'-0.4"] 700 [2'-3.6"] THIS IS A PROPRIETARY DESIGN OF AERIAL FACILITIES LTD. REPRODUCTION OR USE OF THIS DESIGN BY OTHERS IS PERMISSIBLE ONLY IF EXPRESSLY AUTHORISED IN WRITING BY AERIAL FACILITIES LTD. PSU CA UTION Heavy DA NGE R Hi gh vol tage OUTPUT TO UHF 1 ANTENNA (X1) THIRD ANGLE PROJECTION ALARMS Tel : 01494 777000 Fax : 01494 777002 Aerial Facilities Limited England 250 [9.9"] CUSTOMER TITLE OUTPUT TO UHF 2 (Z) DOWNLINK INPUT UHF 1 (X) 1A ISSUE DESCRIPTION PRODUCTION ISSUE DRAWING.No 60-055992 UPGRADE OUTLINE DRAWING PASADENA BLUE LINE. LOCATION 1.UHF1 No DATE 01/07/03 MATERIAL: MILD STEEL FINISH: PAINTED TO RAL 9017 SEMIGLOSS TRAFFIC BLACK WALL FIXINGS: M8 (5/16") RF CONNECTORS: N TYPE FEMALE ENVIRONMENTAL CLASS: IP65 DOWNLINK INPUT/UPLINK OUTPUT (ANTENNA) (J7) UPLINK OUTPUT UHF 1 (W) INPUT FROM UHF 2 (Y) 709 [2'-3.9"] BY MNR 4.2 Drg. Nō. 60-055994 Location one, UHF1A (Upgrade) Case Outline Drawing H/book Number:-60-055900HBKM Issue No:-2 Date:-20/10/2003 CHKD PBL UHF1/1A 1 & 2 Air Interface Maintenance Handbook Page:-27 of 85 GD APPD 15/10/02 DATE ALL DIMENSIONS ARE IN mm UNLESS OTHERWISE STATED PB DBS DRAWN CABLE GLANDS (FIBRE OPTICS) M6 EARTH STUD 620 [2'-0.4"] 555 [1'-9.9"] ALARM NO DECIMAL PLACE ± 1mm ONE DECIMAL PLACE ± 0.3mm TWO DECIMAL PLACES ± 0.1mm TOLERANCES SCALE - N A eri al Faci l i t i es Li mi t ed E ngl and P roduct ref : UHF 2 1:5 670 [2'-2.4"] CE - 620 [2'-0.4"] 700 [2'-3.6"] THIS IS A PROPRIETARY DESIGN OF AERIAL FACILITIES LTD. REPRODUCTION OR USE OF THIS DESIGN BY OTHERS IS PERMISSIBLE ONLY IF EXPRESSLY AUTHORISED IN WRITING BY AERIAL FACILITIES LTD. PSU CA UTI ON Heavy DA NGE R Hi gh vol tage THIRD ANGLE PROJECTION ALARMS 115V AC INPUT Tel : 01494 777000 Fax : 01494 777002 DOWNLINK INPUT UHF 1 Aerial Facilities Limited England CUSTOMER TITLE 250 [9.9"] MATERIAL: MILD STEEL FINISH: PAINTED TO RAL 9017 SEMIGLOSS TRAFFIC BLACK WALL FIXINGS: M8 (5/16") RF CONNECTORS: N TYPE FEMALE ENVIRONMENTAL CLASS: IP65 DOWNLINK INPUT/UPLINK OUTPUT UHF 2 (ANTENNA) DRAWING.No OUTLINE DRAWING 60-055991 PASADENA BLUE LINE. LOCATION 1.UHF2 ISSUE DATE 15/10/02 PRODUCTION ISSUE 1A DESCRIPTION 21/10/02 DECIMAL EQUIV'S 1B No 30/10/02 ECN2746 2A UPLINK OUTPUT UHF 1 709 [2'-3.9"] BY DBS DBS DBS 4.3 Drg. Nō. 60-055991, Location One, UHF 2 Case Outline Drawing H/book Number:-60-055900HBKM Issue No:-2 32dB 4 7 0 M Hz 20dB dB dB 20dB 4 8 5 M Hz dB T4 60-055902 1 2 - 0 0 4 2 0111 - 0 0 7 3 0 1 02-013401 30dB 20dB dB 4 8 6 M Hz - 7 2 d Bm + 1 8 d Bm 4 8 3 M Hz 32dB 11-007401 02-013401 UHF 2 60-055901 - 3 d Bm 20dB 20dB 20dB 20dB -23d Bm1 1 - 0 0 7 3 0 2 470. 2125M H z T3 15dB 11-007302 15dB 473. 3625M H z 15dB 473. 1375M H z 15dB -23d Bm1 1 - 0 0 7 3 0 2 470. 2625M H z 482. 2375M H z T9 30dB 30dB 473. 0875M H z 20dB 20dB -23d Bm 470. 3625M H z T1 2 30dB 11-007402 20dB 15dB 20dB 20dB 25dB 20dB 32dB -20d Bm 6dB 486. 5625M H z -20d Bm 6dB 486. 0625M H z 6dB -20d Bm 486. 2875M H z dB - 1 9 d Bm 11-007401 32dB 11-007401 32dB -20d Bm 6dB - 3 d Bm 11-007401 32dB 11-007401 - 2 7 d Bm 486. 3125M H z -35d B m 483. 5625M H z -35d B m 483. 0625M H z -35d B m 483. 2875M H z -35d B m 483. 3125M H z T9 dB dB -23d Bm1 1 - 0 0 7 4 0 2 470. 1375M H z -23d Bm 473. 2625M H z -22d Bm 1 2 - 0 0 1 8 0111 - 0 0 7 3 0 1 02-013401 5dB dB 473. 2125M H z 30dB 20dB 4 7 3 M Hz 5dB -22d Bm 1 1 - 0 0 6 1 0111 - 0 0 7 3 0 1 485. 2375M H z 02-013401 -12d Bm dB 16dB 32dB 4 8 2 M Hz 11-007401 02-013401 32dB 11-007401 02-013401 60-055903 UHF 1 - 6 2 d Bm + 2 0 d Bm dB 1 2 - 0 1 6 3 0111 - 0 0 7 4 0 1 02-013401 dB 30dB 30dB 4 7 3 M Hz - 6 2 d Bm + 2 0 d Bm 4 7 0 M Hz 20dB -23d Bm1 1 - 0 0 7 4 0 2 470. 0875M H z LO C A TIO N O N E J2 - 8 2 d Bm J1 J7 - 7 2 d Bm 11-007401 02-013401 UHF 1A T2 T1 - 1 5 d Bm - 1 5 d Bm - 1 5 d Bm - 1 5 d Bm W - 1 9 d Bm dB dB PBL UHF1/1A 1 & 2 Air Interface Maintenance Handbook Date:-20/10/2003 Page:-28 of 85 T6 T7 4 8 5 - 4 8 6 M Hz 1 9 d Bm 60-056104 1 7 d Bm dB dB 30dB dB 20dB 30dB 16dB AGC DET 20dB 20dB 20dB 20dB 20dB 20dB 20dB 20dB 20dB 4 8 3 M Hz 30dB 2 7 d Bm - 5 7 d Bm HL 4 8 3 - 4 8 6 M Hz 4 8 3 M Hz - 3 0 d Bm 20dB 813. 7625M H z 20dB 814. 4375M H z 20dB 815. 4375M H z 20dB 20dB 813. 2375M H z 812. 9375M H z 20dB 814. 7625M H z 20dB T1 1 814. 9375M H z 20dB 812. 7625M H z 20dB 1 7 d Bm 30dB 800MHz - 7 8 d Bm 8 0 0 M Hz V HF 1 8 d Bm - 6 0 d Bm - 6 0 d Bm - 6 2 d Bm L CX 2 0 d Bm 1 8 d Bm 8 1 2 - 8 1 5 M Hz 11-005902 11-006702 20dB VHF 8 5 7 - 8 6 0 M Hz 12-000201 30dB - 3 0 d Bm - 4 9 d Bm - 2 9 d Bm - 7 9 d Bm dB dB - 1 1 d Bm - 1 0 d Bm 1 9 d Bm 11-005902 L CX 1 8 d Bm - 5 0 d Bm - 5 0 d Bm 4 8 3 - 4 8 6 M Hz 02-007302 02-013401 02-010401 02-010401 J3 J4 2 0 d Bm L CX 2 0 d Bm 1 8 d Bm - 5 0 d Bm - 5 0 d Bm 4 7 0 - 4 7 5 M Hz 02-007302 - 5 7 d Bm 4 8 5 - 4 8 6 M Hz 2 6 d Bm 12-004201 20dB 11-007302 02-013401 dB - 2 0 d Bm - 2 0 d Bm 11-005902 858. 7625M H z 859. 4375M H z 860. 4375M H z 858. 2375M H z 857. 9375M H z 859. 7625M H z 859. 9375M H z 857. 7625M H z 02-007302 02-010401 02-010401 2 8 d Bm 4 7 0 - 4 7 5 M Hz 4 7 3 M Hz 02-007302 02-013401 20dB 11-006102 11-007302 11-007301 02-013401 AG C dB 16dB 20dB 20dB - 6 5 d Bm 4 8 5 - 4 8 6 M Hz 20dB dB AG C 11-007302 20dB 4 7 0 M Hz 02-013401 1 1 - 0 0 7 3 0022 - 0 1 3 4 0 1 dB 12-004201 AG C 3 0 d Bm 12-001801 11-006102 11-007302 - 1 0 d Bm - 1 1 d Bm - 3 0 d Bm 30dB 12-000201 8 1 2 - 8 1 5 M Hz 20dB 11-005902 11-006702 30dB A GC DET 20dB 11-007302 16dB 60-056102 - 4 9 d Bm - 3 0 d Bm - 7 9 d Bm - 2 9 d Bm 8 5 7 - 8 6 1 M Hz - 7 8 d Bm 02-007302 4 8 3 M Hz L O 02-007302 60-056105 - 1 5 d Bm - 1 5 d Bm T8 - 1 5 d Bm UNIT 1 60-056002 A GC DET dB 11-006102 11-007302 20dB 11-007302 UNIT 2 4 8 5 - 4 8 6 M Hz 4 7 3 M Hz 02-007302 02-007302 4 8 3 M Hz 4 7 0 M Hz 02-007302 60-056001 E UNIT 2 - 1 7 d BmH - 1 5 d Bm - 1 5 d Bm UNIT 1 02-007302 LO C A TIO N TW O J6 - 1 5 d Bm - 1 5 d Bm - 1 5 d Bm T5 TU N N E L O N E & TW O J5 4.4 Complete System Diagram Sketch 4.5 UHF1/1A & UHF2 System Diagram Sketch UHF 1A 11-007402 470.0875MHz 30dB 20dB 02-013401 -72dBm J7 32dB 470.1375MHz dB 30dB 12-016301 11-007402 15dB 473.1375MHz dB 30dB W -19dBm X dB 15dB 473.3625MHz 15dB 60-055903 T9 11-007402 32dB 15dB 11-007402 20dB dB 12-001801 11-007302 dB 20dB 470.2125MHz 20dB T3 20dB -23dBm 473.2625MHz -22dBm 5dB 30dB 20dB dB 473MHz 11-006101 11-007302 02-013401 16dB 20dB 473.2125MHz 485.2375MHz dB -12dBm 15dB -27dBm T9 60-055901 UHF 2 20dB -35dBm 483.2875MHz 11-007402 20dB -35dBm dB 483.0625MHz 483MHz 20dB 25dB -35dBm 483.5625MHz -72dBm 20dB -35dBm +18dBm 11-007402 483.3125MHz 32dB dB -22dBm 5dB 485MHz 02-013401 -3dBm -23dBm11-007302 470MHz 02-013401 20dB -23dBm11-007302 470.2625MHz 32dB -62dBm +20dBm 11-007302 482.2375MHz dB 482MHz 02-013401 473.0875MHz T12 473MHz 02-013401 J2 20dB dB -23dBm UHF 1 -82dBm 30dB 470.3625MHz -62dBm +20dBm 30dB J1 20dB -23dBm11-007402 470MHz 02-013401 -23dBm11-007402 11-007402 32dB -3dBm 11-007402 32dB 11-007402 -15dBm dB T1 32dB -15dBm 11-007402 32dB 486.3125MHz 6dB T4 02-013401 12-004201 11-007302 30dB 486MHz 20dB -20dBm 486.2875MHz 6dB dB -19dBm -20dBm 486.0625MHz T2 -15dBm -15dBm 6dB -20dBm 486.5625MHz 60-055902 6dB -20dBm LOCATION ONE PBL UHF1/1A 1 & 2 Air Interface Maintenance Handbook H/book Number:-60-055900HBKM Issue No:-2 Date:-20/10/2003 Page:-29 of 85 5. SUB-UNIT MODULES UHF 1 Air Interface (60-055901) 5.1 5.1.1 5.1.1.1 Bandpass Duplexers (02-013401) Description The bandpass filters are multi-section designs with a bandwidth dependent upon the passband frequencies, (both tuned to customer requirements). The response shape is basically Chebyshev with a passband design ripple of 0.1dB. The filters are of combline design, and are carefully aligned during manufacture in order to optimise the insertion loss, VSWR and intermodulation characteristics of the unit. The tuned elements are silver-plated to reduce surface ohmic losses and maintain a good VSWR figure and 50Ω load at the input and output ports. Note that the same filter is used for both UHF 1 & 2, but tuned differently depending on the required frequencies and bandwidth for each air interface. Being passive devices, the bandpass filters should have an extremely long operational life and require no maintenance. Should a filter be suspect, it is usually most time efficient to replace the module rather than attempt repair or re-tuning. No adjustments should be attempted without full network sweep analysis facilities to monitor both insertion loss and VSWR simultaneously. 5.1.1.2 Technical Specification PARAMETER Passband: FILTER 1 FILTER 2 Insertion Loss: FILTER 1 FILTER 2 Rejection: FILTER 1 SPECIFICATION 483.2-483.6 MHz 486.2-486.6 MHz 2.7 dB typical 2.7 dB typical 483.2-483.6 MHz > 80 dB FILTER 2 486.2-486.6 MHz > 80 dB Power Rating: Impedance: VSWR: Connectors: 250 Watt 50 ohm Better than 1.2:1 SMA female PBL UHF1/1A 1 & 2 Air Interface Maintenance Handbook H/book Number:-60-055900HBKM Issue No:-2 Date:-20/10/2003 Page:-30 of 85 5.1.2 5.1.2.1 2 & 4 Way UHF Splitters (05-002603 & 05-003401) Description The Splitter/Combiners used are UHF (300-500MHz) devices for accurately matching two or more RF signals to single or multiple ports, whilst maintaining an accurate 50Ω load to all inputs/outputs and ensuring that the VSWR and insertion losses are kept to a minimum. Any unused ports will be terminated with an appropriate 50Ω load. 5.1.2.2 Technical Specification (05-002603) PARAMETER Frequency Range: Bandwidth: Inputs: Outputs: Insertion Loss: Isolation: Return Loss (VSWR) – Input: Return Loss (VSWR) – Output: Impedance: Power Rating – Splitter: Power Rating – Combiner: Connectors: Size: Weight: 5.1.2.3 SPECIFICATION 380 - 520 MHz 140 MHz 3.5 dB (typical) >18 dB Better than 1.3:1 Better than 1.3:1 50 ς 20 Watts 0.5 Watt SMA female 54 x 44 x 21 mm (including connectors) 200 g Technical Specification 05-003401 PARAMETER Frequency range: Bandwidth: Rejection: Insertion loss: Connectors: Weight: operational Temperature range: storage SPECIFICATION 70 – 250MHz 180MHz >14dB (in band) SMA <1.5Kgm -10ΒC to +55ΒC -40ΒC to +70ΒC PBL UHF1/1A 1 & 2 Air Interface Maintenance Handbook H/book Number:-60-055900HBKM Issue No:-2 Date:-20/10/2003 Page:-31 of 85 5.1.3 ¼Watt 0- -30dB Switched Attenuator (10-000701) 5.1.3.1 General Application In many practical applications for Cell Enhancers etc., the gain in each path is found to be excessive. Therefore, provision is made within the unit for the setting of attenuation in each path, to reduce the gain. 5.1.3.2 Switched Attenuators The AFL switched attenuators are available in two different types; 0 – 30dB in 2 dB steps (as in this case), or 0 – 15dB in 1 dB steps. The attenuation is simply set using the four miniature toggle switches on the top of each unit. Each switch is clearly marked with the attenuation it provides, and the total attenuation in line is the sum of the values switched in. They are designed to maintain an accurate 50Ω impedance over their operating 5.1.4 Low Noise Amplifiers (11-006102, 11-007302 & 11-007402) 5.1.4.1 General Description The low noise amplifiers used are double or single stage solid-state low-noise amplifiers. Class A circuitry is used in the units to ensure excellent linearity over a very wide dynamic range. The active devices are very moderately rated to provide a long troublefree working life. There are no adjustments on these amplifiers, and in the unlikely event of failure then the entire amplifier should be replaced. Note that all three amplifiers use similar DC power circuit boards. 5.1.4.2 Technical Specification (11-006102) PARAMETER Frequency range: Bandwidth: Gain: 1dB Compression Point: 3rd order intercept: Input return loss: Output return loss: VSWR: Noise figure: Connectors: Supply: operational: Temperature range: storage: Weight: SPECIFICATION 70 – 500MHz <430MHz 15.5dB (typical) +31dBm (typical) +46dBm (typical) >20dB >20dB Better than 1.5:1 <4.8dB SMA female 530mA @ 10 to 24V DC (typical) -10°C to +60°C -40°C to +70°C 260gms PBL UHF1/1A 1 & 2 Air Interface Maintenance Handbook H/book Number:-60-055900HBKM Issue No:-2 Date:-20/10/2003 Page:-32 of 85 H/book Number:-60-055900HBKM Issue No:-2 Date:-20/10/2003 11-006102 380-500MHz 1W 12-24vDC ******** **/**/20** OR 0086 AFL 19 OUT 34 IN 4 PLACES see note 2 28 see note 2 31 CHKD PBL UHF1/1A 1 & 2 Air Interface Maintenance Handbook Page:-33 of 85 APPD 22/03/02 DATE ALL DIMENSIONS ARE IN mm UNLESS OTHERWISE STATED MNR DRAWN NO DECIMAL PLACE ± 1mm ONE DECIMAL PLACE ± 0.3mm TWO DECIMAL PLACES ± 0.1mm TOLERANCES SCALE THIS IS A PROPRIETARY DESIGN OF AERIAL FACILITIES LTD. REPRODUCTION OR USE OF THIS DESIGN BY OTHERS IS PERMISSIBLE ONLY IF EXPRESSLY AUTHORISED IN WRITING BY AERIAL FACILITIES LTD. 1.5:1 2. LIDS,ITEMS 2 & 3 AND LABELS,ITEMS 31,34 & 35,TO BE FITTED ON TEST 1. SOLDER JOINTS TO BE MADE USING IN REF. FREQ. POWER S/N DATE AFL DE V ICE S E LE C TR OS TA TI C S E N S I TI V E FOR H A ND LI N G OB S E R V E P RE C A U TI ON S ATTENTION AFL see note 2 21 RL1 R40 22 England Aerial Facilities Ltd 33 24 Tel : 01494 777000 Fax : 01494 777002 CON1 REG3 17 R 16 R 17 35 C 17 LABEL DETAILS - SCALE 1:1 L13 L14 J5 J4 26 30 No DRG.No RF PCB 11-006102 24 25 DATE 22/03/02 IN 2 PLACES DC PCB 32 ISSUE DESCRIPTION see note 3 IN 2 PLACES 34 PRODUCTION ISSUE 1A 27 10 25 20 WITH RELAY ASSEMBLY CUSTOMER TITLE R51 R50 R49 15 380-500MHz 1W AMPLIFIER 27 23 R43 R44 16 R4 5 C 16 C 15 R10 R 15 L12 L11 R9 R14 C9 C 11 R13 C12 C 14 11-006125 Issue.1 R 12 T2 L10 L6 L9 COMPONENTS TO BE ADDED TO 11-003912,ITEM 15,DC PCB SUB-ASSEMBLY BY MNR 5.1.4.3 Drg. Nō. 11-006102, Low Noise Amplifier General Assembly H/book Number:-60-055900HBKM Issue No:-2 Date:-20/10/2003 C1 PBL UHF1/1A 1 & 2 Air Interface Maintenance Handbook Page:-34 of 85 THIRD ANGL E PROJECTION RF IN No 1A R1 IS S UE C2 8.2pF DE S CRIP TI ON PRODUCTION ISSUE 910R R2 5R6 910R R3 DA TE 23/01/02 18nH L1 18nH L2 MNR CHK D DRA WN C3 3.3pF L3 18nH L4 18nH R4 100R C8 1nF APPD IB 2 3/01 /02 DA TE A LL DIME NS IONS A RE IN mm UNLE S S OTHE RWIS E S TA TE D CB MNR 6.8pF C4 R6 56R R12 10K R8 10K NO DE CIMA L P LA CE ± 1mm ONE DE CIMA L P LA CE ± 0. 3mm TWO DE CI MA L P LA CE S ± 0.1mm TOLE RA NCE S L9 180nH R13 0R0 R9 0R0 L7 180nH R14 R10 S CA LE N.T.S ARE NOT USED IN THIS BUILD T2 CYL5 ANY COMPONENTS IN L6 6.8nH L5 6.8nH R5 56R T1 CYL5 THIS IS A P ROP RIE TA RY DE S IGN OF A E RIA L FA CILITI E S LTD. RE P RODUCTION OR US E OF THI S DE S I GN B Y OTHE RS I S P E RMIS S IB LE ONLY I F E X P RE S S LY A UTHORIS E D I N WRITI NG B Y A E RI A L FA CI LI TI E S LTD. 220pF C7 R11 R7 C6 1nF 220pF C5 L8 L10 7.5nH C11 220pF C9 220pF 7.5nH 220pF C14 220pF C13 L11 18nH L12 18nH Tel : 01494 777000 Fax : 01494 777002 England Aerial Facilities Limited C12 6.8pF C10 6.8pF CUS TOME R TITLE 6.8pF C15 R15 100R L13 C17 8.2pF 10 DRA WI NG No (RF) CIRCUIT DIAGRAM R17 R16 0R0 11 11-006170 11 380-500MHz 1W AMPLIFIER 18nH L14 C16 3.3pF 18nH 10 12 (OPTIONAL) RF OUT RF OUT 12 5.1.4.4 Drg. Nō. 11-006170, LNA RF Circuit Diagram H/book Number:-60-055900HBKM Issue No:-2 Date:-20/10/2003 CHKD PBL UHF1/1A 1 & 2 Air Interface Maintenance Handbook Page:-35 of 85 APPD IB 23/01/02 DATE ALL DIMENSIONS ARE IN mm UNLESS OTHERWISE STATED CB MNR DRAWN RF IN -ve +6V 220mA -ve +6V 220mA DC INPUT NO DECIMAL PLACE ± 1mm ONE DECIMAL PLACE ± 0.3mm TWO DECIMAL PLACES ± 0.1mm TOLERANCES SCALE THIS IS A PROPRIETARY DESIGN OF AERIAL FACILITIES LTD. REPRODUCTION OR USE OF THIS DESIGN BY OTHERS IS PERMISSIBLE ONLY IF EXPRESSLY AUTHORISED IN WRITING BY AERIAL FACILITIES LTD. RF PCB FOR CIRCUIT DIAGRAM SEE 11-006170 CON2 - J5 CON2 - J4 Tel : 01494 777000 Fax : 01494 777002 DC PCB +8V SCHEMATIC DIAGRAM DRAWING.No RF OUT DATE 23/01/02 OC GOOD/0v BAD TTL ALARM/0v GOOD TTL VOLTAGE SET BY MNR RELAY CONTACT GOOD RELAY COMMON RELAY CONTACT BAD GROUND +12V DC I/P 9 WAY 'D' PIN OUTS CON1 11-006171 ISSUE DESCRIPTION PRODUCTION ISSUE 9 CON1 8 CON1 7 CON1 5 CON1 4 CON1 3 CON1 2 CON1 380-500MHz 1W AMPLIFIER CUSTOMER TITLE No 1A FOR CIRCUIT DIAGRAM SEE 11-003971 REG3 LM7808CT = ONLY APPLIES TO 11-006802 J5 2 J5 1 J4 2 J4 1 DC OUTPUT Aerial Facilities Limited England 5.1.4.5 Drg. Nō. 11-006171, LNA DC Wiring Diagram H/book Number:-60-055900HBKM Issue No:-2 Date:-20/10/2003 CHKD V _IN J1 J5 J4 J3 J4 J5 J3 J1 P1 J2 >12V DC I/P J2 C13 10u 1u C4 ZD3 5.1V 10u C14 C8 10u 0R R28 C5 1u IC3 IC2 100n C11 100n C17 I CL7660C I CL7660C 100R R38 C15 10u C9 10u 10u C16 10u C10 1K R52 1K R47 C7 470p C6 10u R40 R39 C18 1u LM337LM RE G2 LM337LM RE G1 C12 1u R41 R50 R51 R44 R43 V R1 R42 P2 R49 R45 PBL UHF1/1A 1 & 2 Air Interface Maintenance Handbook Page:-36 of 85 IB ALL DIMENSIONS ARE IN mm UNLESS OTHERWISE STATED APPD 24/09/01 DATE NO DECIMAL PLACE ± 1mm ONE DECIMAL PLACE ± 0.3mm TWO DECIMAL PLACES ± 0.1mm TOLERANCES SCALE THIS IS A PROPRIETARY DESIGN OF AERIAL FACILITIES LTD. REPRODUCTION OR USE OF THIS DESIGN BY OTHERS IS PERMISSIBLE ONLY IF EXPRESSLY AUTHORISED IN WRITING BY AERIAL FACILITIES LTD. 1. * IF APPLICABLE, VALUES WILL BE DETERMINED AT A HIGHER LEVEL BOM 2. CONNECTORS J1-5 TO BE FITTED AS NECESSARY CON 1 CON 1 CB DJL DRAWN V _OUT 100n C19 R46 1K R48 1K R53 470R R56 R55 R54 I C4:A 0R R29 I C4:B ZD1 1.23V 120R R2 R1 1K 8 R3 C1 1u 100K R5 100K R4 12 13 IC1:D LM324M 11 14 100K R6 THIRD ANGLE PROJECTION IC1: A LM324M 100K R57 Chesham(01494)778301 Fax (01494)778910 Aerial Facilities Limited England R7 120R R11 C2 100n 1K 9 - 3K 6 R12 10 R9 1K R8 I C1: B D1 LL4148 D2 LL4148 CUSTOMER TITLE LM324M 270K R10 LM324M I C1: C 270K R35 10K R32 P7 D3 R23 DRAWING.No CIRCUIT DIAGRAM 11-003971 ISSUE DESCRIPTION DC PCB FOR LNA's AND LPA's, No DATE BY DJL TAS PROTOTYPE ISSUE 24/9/01 26/11/01 PRODUCTION ISSUE(ECN2359) CON 1 CON 1 CON 1 1A P4 CON 1 AA B CW71 TR3 P5 DJL CON 1 R58 1K DJL RL1/1 4K 7 R25 R59 CON 1 17/4/02 25/7/02 4K 7 10K B CW71 TR2 R24 RL1 R18 22K ECN2686 P6 P8 R22 10K P3 ZD2 3V 3 R17 2K 2 ECN2518 TR1 LL4148 560R R19 TR5 B CW71 TR6 FZT751 3A 56R R27 TR4 B CW71 1K R16 2A RL1/2 R21 4K 7 R31 10K R20 2K 4 R15 4K 7 B CW71 TR8 4K 7 R36 C3 1U 3K R14 4K 7 B CW71 TR7 1K R33 10K R34 LE D1 4K 7 R13 5.1.4.6 Drg. Nō. 11-003971, LNA DC Schematic Diagram 5.1.4.7 Technical Specification (11-007302) PARAMETER Frequency range: Bandwidth: Gain: 1dB Compression Point: 3rd order intercept: Input/Output return loss: Noise figure: Connectors: Supply: operational: Temperature range: storage: Weight: Size: SPECIFICATION 380-500MHz <140MHz 20-22dB +23.5dB (typical) +36dB (typical) >20dB <1.3dB SMA female 200-230mA @ 24V DC -10°C to +55°C -30°C to +70°C <300gms 90 x 55 x 30.2 (case only) PBL UHF1/1A 1 & 2 Air Interface Maintenance Handbook H/book Number:-60-055900HBKM Issue No:-2 Date:-20/10/2003 Page:-37 of 85 H/book Number:-60-055900HBKM Issue No:-2 Date:-20/10/2003 11-007302 380-500MHz 20dB 10-24V DC ******** **/**/20** DE V ICE S 0086 AFL 19 OUT IN 34 IN 4 PLACES see note 2 28 see note 2 31 CHKD PBL UHF1/1A 1 & 2 Air Interface Maintenance Handbook Page:-38 of 85 APPD IB 9/7/02 DATE ALL DIMENSIONS ARE IN mm UNLESS OTHERWISE STATED CB DBS DRAWN NO DECIMAL PLACE ± 1mm ONE DECIMAL PLACE ± 0.3mm TWO DECIMAL PLACES ± 0.1mm TOLERANCES SCALE THIS IS A PROPRIETARY DESIGN OF AERIAL FACILITIES LTD. REPRODUCTION OR USE OF THIS DESIGN BY OTHERS IS PERMISSIBLE ONLY IF EXPRESSLY AUTHORISED IN WRITING BY AERIAL FACILITIES LTD. 1.5:1 2. LIDS,ITEMS 2 & 3 AND LABELS,ITEMS 31,34 & 35,TO BE FITTED ON TEST OR E LE C TR OS TA TI C S E N S I TI V E FOR H A ND LI N G OB S E R V E P RE C A U TI ON S 1. SOLDER JOINTS TO BE MADE USING REF. FREQ. GAIN S/N DATE AFL see note 2 ATTENTION 35 22 21 CPL1 W7 C2 C1 RL1 England W2 L5 R4 TR1 + C8 R16 27 L3 R2 C9 L1 W5 30 Aerial Facilities Ltd C5 C4 20 C21 W6 15 26 IN 2 PLACES R1 R19 RF OUT R39 Tel : 01494 777000 Fax : 01494 777002 24 CON1 REG3 J1 J3 J2 AFL COMPONENTS TO BE ADDED TO 11-003912,ITEM 15,DC PCB SUB-ASSEMBLY LABEL DETAILS - SCALE 1:1 J31 J32 C12 27 No 1A 10 25 24 33 ISSUE DESCRIPTION PRODUCTION ISSUE 17 DC PCB 25 32 LOW NOISE AMPLIFIER 380-500MHz 23 IN 3 PLACES CUSTOMER DRG.No 11-007302 (20dB) ASSEMBLY DRAWING (WITH RELAY) TITLE W1 16 R50 R49 R43 R44 DATE 9/7/02 RF PCB BY DBS 5.1.4.8 Drg. Nō. 11-007302, LNA Assembly With Alarm Relay H/book Number:-60-055900HBKM Issue No:-2 Date:-20/10/2003 CHKD PBL UHF1/1A 1 & 2 Air Interface Maintenance Handbook Page:-39 of 85 APPD IB 5/7/02 DATE ALL DIMENSIONS ARE IN mm UNLESS OTHERWISE STATED CB DBS DRAWN RF INPUT 51R R1 11303-3 CP L1 C4 1nF C3 3.3pF NO DECIMAL PLACE ± 1mm ONE DECIMAL PLACE ± 0.3mm TWO DECIMAL PLACES ± 0.1mm TOLERANCES L4 330nH Ø1.6x6 turns SCALE L2 CLY 2 TR2 CLY 2 1nF TR1 Ø1. 6x6 t urns L1 L3 330nH L5 C5 C6 R6 10K R3 100R 1nF 1nF R7 560R 1nF C13 1nF C12 L6 C10 R4 560R 100nH 100nH 1nF C9 10K 1nF R5 R2 0R0 100R W7 0R0 R19 C1 C7 3.3pF RF OUTPUT THIS IS A PROPRIETARY DESIGN OF AERIAL FACILITIES LTD. REPRODUCTION OR USE OF THIS DESIGN BY OTHERS IS PERMISSIBLE ONLY IF EXPRESSLY AUTHORISED IN WRITING BY AERIAL FACILITIES LTD. CP L2 11303-3 R8 51R R9 R11 W2 0R0 W1 0R0 W5 0R0 Tel : 01494 777000 Fax : 01494 777002 Aerial Facilities Limited England HE A DE R P IN J11 HE A DE R P IN J12 HE A DE R P IN J32 HE A DE R P IN J31 0R0 W6 0R0 R10 CUSTOMER TITLE 2A No 1A ISSUE DESCRIPTION PRODUCTION ISSUE ECN2718 DRAWING.No 11-007370 (20dB) RF PCB CIRCUIT DIAGRAM LOW NOISE AMPLIFIER 380-500MHz ATTENUATOR GROUP (Select values on Test) DATE 5/7/02 19/9/02 BY DBS DBS 5.1.4.9 Drg. Nō. 11-007370, LNA RF Circuit Diagram H/book Number:-60-055900HBKM Issue No:-2 Date:-20/10/2003 CHKD PBL UHF1/1A 1 & 2 Air Interface Maintenance Handbook Page:-40 of 85 APPD IB 8/7/02 DATE ALL DIMENSIONS ARE IN mm UNLESS OTHERWISE STATED CB DBS DRAWN RF IN -ve 5V 75mA -ve 5V 75mA DC INPUT NO DECIMAL PLACE ± 1mm ONE DECIMAL PLACE ± 0.3mm TWO DECIMAL PLACES ± 0.1mm TOLERANCES SCALE THIS IS A PROPRIETARY DESIGN OF AERIAL FACILITIES LTD. REPRODUCTION OR USE OF THIS DESIGN BY OTHERS IS PERMISSIBLE ONLY IF EXPRESSLY AUTHORISED IN WRITING BY AERIAL FACILITIES LTD. RF PCB FOR CIRCUIT DIAGRAM SEE 11-007370 J11 - J12 J31 - J32 J12 2 J11 1 J32 2 J31 1 DC OUTPUT Tel : 01494 777000 Fax : 01494 777002 Aerial Facilities Limited England DC PCB +8V ISSUE DESCRIPTION PRODUCTION ISSUE 9 CON1 8 CON1 7 CON1 5 CON1 4 CON1 3 CON1 2 CON1 DRAWING.No RF OUT DATE 8/7/02 OC GOOD/0v BAD TTL ALARM/0v GOOD TTL VOLTAGE SET BY DBS RELAY CONTACT GOOD RELAY COMMON RELAY CONTACT BAD GROUND 10-24V DC I/P 9 WAY 'D' PIN OUTS CON1 11-007371 (20dB) RF SCHEMATIC DIAGRAM LOW NOISE AMPLIFIER. 380-500MHz CUSTOMER TITLE No 1A FOR CIRCUIT DIAGRAM SEE 11-003971 REG3 LM7808CT 5.1.4.10 Drg. Nō. 11-007371, LNA DC Wiring Diagram 5.1.4.11 Technical Specification (11-007402) PARAMETER Frequency range: Bandwidth: Gain: 1dB Compression Point: 3rd order intercept: Input/Output return loss: Noise figure: Connectors: Supply: operational: Temperature range: storage: Weight: Size: SPECIFICATION 380-500MHz <140MHz 30-32dB +22dB (typical) +34dB (typical) >19dB <1.3dB SMA female 300-330mA @ 10-24V DC -10°C to +55°C -30°C to +70°C <300gms 90 x 55 x 30.2 (case only) PBL UHF1/1A 1 & 2 Air Interface Maintenance Handbook H/book Number:-60-055900HBKM Issue No:-2 Date:-20/10/2003 Page:-41 of 85 Issue No:-2 Date:-20/10/2003 11-007402 380-500MHz 30dB 10-24V DC ******** **/**/20** IN 4 PLACES see note 2 OR 0086 AFL 19 OUT IN 35 28 34 CHKD PBL UHF1/1A 1 & 2 Air Interface Maintenance Handbook Page:-42 of 85 APPD IB 9/7/02 DATE ALL DIMENSIONS ARE IN mm UNLESS OTHERWISE STATED CB DBS DRAWN NO DECIMAL PLACE ± 1mm ONE DECIMAL PLACE ± 0.3mm TWO DECIMAL PLACES ± 0.1mm TOLERANCES SCALE THIS IS A PROPRIETARY DESIGN OF AERIAL FACILITIES LTD. REPRODUCTION OR USE OF THIS DESIGN BY OTHERS IS PERMISSIBLE ONLY IF EXPRESSLY AUTHORISED IN WRITING BY AERIAL FACILITIES LTD. LABEL DETAILS - SCALE 1:1 see note 2 see note 2 1.5:1 2. LIDS,ITEMS 2 & 3 AND LABELS,ITEMS 31,34 & 35,TO BE FITTED ON TEST 1. SOLDER JOINTS TO BE MADE USING REF. FREQ. GAIN S/N DATE 31 AFL DE V ICE S E LE C TR OS TA TI C S E N S I TI V E FOR H A ND LI N G OB S E R V E P RE C A U TI ON S ATTENTION 22 21 CPL1 C24 C2 C1 TR3 C22 L7 England W2 C18 L5 R4 TR1 + J31 J32 C12 IC1 C14 ZD1 W1 No 1A 2A 27 23 ISSUE CUSTOMER DRG.No 11-007402 (30dB) ASSEMBLY DRAWING (WITH RELAY) DATE 9/7/02 DESCRIPTION 24/9/02 33 RF PCB PRODUCTION ISSUE 10 25 24 DC PCB 25 32 ECN2722 17 IN 3 PLACES LOW NOISE AMPLIFIER 380-500MHz 16 R57 R50 R49 R43 R44 TITLE C15 C16 C17 R15 R12 R14 C8 R16 L3 R2 C9 L1 Aerial Facilities Ltd C5 C4 W3 W4 R17 W5 IC4 27 R41 30 20 R55 C20 C21 W6 C23 W7 15 RL1 R54 R53 26 IN 2 PLACES R1 R19 RF OUT R39 Tel : 01494 777000 Fax : 01494 777002 24 CON1 REG3 J1 J3 J2 C1 9 COMPONENTS TO BE ADDED TO 11-003912,ITEM 15,DC PCB SUB-ASSEMBLY R1 8 AFL H/book Number:-60-055900HBKM R1 3 BY DBS DBS 5.1.4.12 Drg. Nō. 11-007402, LNA General Assembly H/book Number:-60-055900HBKM Issue No:-2 Date:-20/10/2003 CHKD PBL UHF1/1A 1 & 2 Air Interface Maintenance Handbook Page:-43 of 85 APPD IB 5/7/02 DATE ALL DIMENSIONS ARE IN mm UNLESS OTHERWISE STATED CB DBS DRAWN RF INPUT 51R R1 11303-3 CP L1 L1 NO DECIMAL PLACE ± 1mm ONE DECIMAL PLACE ± 0.3mm TWO DECIMAL PLACES ± 0.1mm TOLERANCES 1nF C3 3.3pF 330nH L3 L4 TR2 330nH Ø1.6x6 turns CLY 2 1nF 10K 100R R6 R3 C6 1nF 1nF R7 560R 1nF C13 1nF C12 560R R4 5R6 L6 C10 1nF W6 1.5pF 100nH 100nH L5 10K C9 R5 1K 5 R18 R2 10nF C20 0R0 R14 100R C5 1nF C17 1K 2 R15 10K 4V 7 L2 SCALE R17 ZD1 HE A DE R P I N J22 1K 5 R12 10K CLY 2 Ø1. 6x6 t urns 7660 I C1 R16 1nF TR1 10uF C15 1nF 2.2pF 1nF C18 C21 W7 0R0 R19 C1 C7 3.3pF C4 10uF C14 RF OUTPUT THIS IS A PROPRIETARY DESIGN OF AERIAL FACILITIES LTD. REPRODUCTION OR USE OF THIS DESIGN BY OTHERS IS PERMISSIBLE ONLY IF EXPRESSLY AUTHORISED IN WRITING BY AERIAL FACILITIES LTD. 1nF C23 L7 HE A DE R P IN J11 HE A DE R P IN J12 HE A DE R P IN J32 HE A DE R P IN J31 1nF C22 330nH 220pF C19 W4 68nH 11303-3 CP L2 1nF C2 W5 CLY 2 51R R8 R13 HE A DE R P I N J21 510R 22R R10 Tel : 01494 777000 Fax : 01494 777002 Aerial Facilities Limited England TR3 B CW61B 1K 2 W3 0R0 W1 1nF W2 R11 240R R9 240R CUSTOMER TITLE ISSUE DESCRIPTION PRODUCTION ISSUE No ECN2722 2A 1A DRAWING.No 11-007470 (30dB) RF PCB CIRCUIT DIAGRAM LOW NOISE AMPLIFIER 380-500MHz ATTENUATOR GROUP (Select values on test) DATE 5/7/02 24/9/02 BY DBS DBS 5.1.4.13 Drg. Nō. 11-007470, LNA RF Circuit Diagram H/book Number:-60-055900HBKM Issue No:-2 Date:-20/10/2003 CHKD PBL UHF1/1A 1 & 2 Air Interface Maintenance Handbook Page:-44 of 85 APPD IB 8/7/02 DATE ALL DIMENSIONS ARE IN mm UNLESS OTHERWISE STATED CB DBS DRAWN RF IN NO DECIMAL PLACE ± 1mm ONE DECIMAL PLACE ± 0.3mm TWO DECIMAL PLACES ± 0.1mm TOLERANCES -ve 5V 75mA SCALE Tel : 01494 777000 Fax : 01494 777002 Aerial Facilities Limited England J12 2 J11 1 J22 2 J32 2 J31 1 DC OUTPUT J21 1 J11 - J12 J21 - J22 J31 - J32 5V 8V -ve 5V 75mA DC INPUT THIS IS A PROPRIETARY DESIGN OF AERIAL FACILITIES LTD. REPRODUCTION OR USE OF THIS DESIGN BY OTHERS IS PERMISSIBLE ONLY IF EXPRESSLY AUTHORISED IN WRITING BY AERIAL FACILITIES LTD. RF PCB FOR CIRCUIT DIAGRAM SEE 11-007470 DC PCB +8V ISSUE DESCRIPTION PRODUCTION ISSUE 9 CON1 8 CON1 7 CON1 5 CON1 4 CON1 3 CON1 2 CON1 DRAWING.No RF OUT DATE 8/7/02 OC GOOD/0v BAD TTL ALARM/0v GOOD TTL VOLTAGE SET BY DBS RELAY CONTACT GOOD RELAY COMMON RELAY CONTACT BAD GROUND 10-24V DC I/P 9 WAY 'D' PIN OUTS CON1 11-007471 (30dB) SCHEMATIC DIAGRAM LOW NOISE AMPLIFIER. 380-500MHz CUSTOMER TITLE No 1A FOR CIRCUIT DIAGRAM SEE 11-003971 REG3 LM7808CT 5.1.4.14 Drg. Nō. 11-007471 LNA DC Wiring Diagram 5.1.5 5Watt Power Amplifier (12-001801) 5.1.5.1 Description The power amplifier fitted to this unit is a multi-stage, solid state class A power amplifier. All the semi-conductor devices are very conservatively rated to ensure low device junction temperatures and a long, trouble free working lifetime. The power amplifier should require no maintenance over its operating life. Under no circumstances should the cover be removed or the side adjustments disturbed unless it is certain that the amplifier has failed; since it is critically aligned during manufacture and any re-alignment will require extensive test equipment. 5.1.5.2 Technical Specification PARAMETER Frequency Range: Bandwidth: Maximum Output Power: Gain: 3rd Order Intercept Point: 1dB Compression Point: VSWR: Connectors: Supply: operational: Temperature range: storage: Size: Weight: SPECIFICATION 400 - 500MHz (tuned to spec.) 20MHz (typical, tuneable) >5W 30dB <+37dBm <+48dBm better than 1.45:1 SMA female 1.25A @ 24V DC -10°C to +55°C -40°C to +70°C 276 x 78 x 40mm (case only) 1.5 kg (excluding heatsink) PBL UHF1/1A 1 & 2 Air Interface Maintenance Handbook H/book Number:-60-055900HBKM Issue No:-2 Date:-20/10/2003 Page:-45 of 85 H/book Number:-60-055900HBKM Issue No:-2 Date:-20/10/2003 PBL UHF1/1A 1 & 2 Air Interface Maintenance Handbook Page:-46 of 85 IS S UE CR0521 PRODUCTION ISSUE DE S CRIP TI ON PRODUCTION ISSUE (CR0962) 2A No TITLE EDITED 2B DATE 16/9/92 27/1/94 23/12/98 08/11/01 DBS DJL SEW TAS CHK D DRA WN L1 L2 15 FB 2 C5 R E G1 APPD 14/09/92 DA TE 21 C6 L6 C7 15 15 L5 23 18 L4 FB 4 R2 C 13 NO DE CIMA L P LA CE ± 1mm ONE DE CIMA L P LA CE ± 0. 3mm TWO DE CI MAL P LACE S ± 0.1mm TOLE RA NCE S SCA LE TR 2 1:1 C 12 L3 FB 3 C 10 23 24 18 20 C8 C9 24V D C I NP U T 16 26 19 Fax (0494)764838 Little Chalfont(0494)763636 England Aerial Facilities Ltd OU TP U T IN 2 PLACES COMPLETE ALL SOLDERING USING ITEM FIT WITH CHAMFERED TAB IN DIRECTION SHOWN --> 14 C 11 R E G2 2 P0SNS PLAN VIEW WITH LID REMOVED THIRD ANGLE PROJECTION THIS IS A P ROP RIE TA RY DE S IGN OF A E RIA L FA CILITI E S LTD. RE P RODUCTION OR US E OF THI S DE SI GN B Y OTHE RS I S PE RMIS S IB LE ONLY I F EX P RE S S LY A UTHORIS E D I N WRITI NG BY A ERI AL FA CI LI TI ES LTD. TRIM 2 TABS TO SUIT PCB. FIT WITH CHAMFERED TAB IN DIRECTION SHOWN --> C4 TR 1 IN 4 POSNS FB 1 C 18 R1 12-1825-3 Issue 1 Aerial Facilities Limited C 14 C 15 11 13 C 16 C3 C 17 A LL DIME NS IONS A RE IN mm UNLE S S OTHE RWIS E S TA TE D DBS 12 C2 C1 I N P UT 25 IN 3 PLACES USED ON CUS TOME R TITLE 18 18 OR IN 2 POSNS 11 DRG. No 12-001801 POWER AMPLIFIER,450MHz,5W GENERAL ASSEMBLY IS S 2B 5.1.5.3 Drg. Nō. 12-001801, 5Watt PA General Assembly Drawing H/book Number:-60-055900HBKM Issue No:-2 Date:-20/10/2003 CHKD PBL UHF1/1A 1 & 2 Air Interface Maintenance Handbook Page:-47 of 85 APPD 19/09/92 DATE RF INPUT C2 1-14p 56p C1 C3 1-14p C4 27p TR1 TCC596 C15 10n 56p C6 ARE 50 ohm STRIPLINES C5 1-14p FB2 FB1 out L2 LM337T C18 560p R1 5R6 SCALE L6 1K R5 C10 1u Fax (0494)764838 Little Chalfont(0494)763636 Aerial Facilities Ltd England REFER TO COMPONENT LISTS 12-1870-C1 & C2 FOR COMPONENT VALUES REFER TO 12-1801-2 & 12-1802-3 FOR COMPONENT POSITIONS NO DECIMAL PLACE ± 1mm ONE DECIMAL PLACE ± 0.3mm TWO DECIMAL PLACES ± 0.1mm TOLERANCES adj REG1 C14 1u L1 in 1K CONDUCTORS SHOWN THUS: C16 1u 1n C20 R3 THIS IS A PROPRIETARY DESIGN OF AERIAL FACILITIES LTD. REPRODUCTION OR USE OF THIS DESIGN BY OTHERS IS PERMISSIBLE ONLY IF EXPRESSLY AUTHORISED IN WRITING BY AERIAL FACILITIES LTD. C17 220p MONITOR 1st STAGE ALL DIMENSIONS ARE IN mm UNLESS OTHERWISE STATED DBS DRAWN C19 24V DC INPUT 12-1801 USED ON 120p C7 in CUSTOMER TITLE L5 1u LM337T REG2 adj No 2A TR2 TP5015 out 1K R4 C9 DRG.No CIRCUIT DIAGRAM 12-001870 ISSUE DESCRIPTION DATE 27/1/94 19/9/92 2A ISS BY DBS DJL SEW RF OUTPUT 19/1/99 R2 1R2 C13 1u PRODUCTION ISSUE (CR0962) C8 1-14p 56p FB3 L3 REF. MONITOR 2nd STAGE CR0521 PRODUCTION ISSUE C12 10n 1n C21 POWER AMPLIFIER,450MHz,10W FB4 L4 C11 220p 1n C22 5.1.5.4 Drg. Nō. 12-001870, 5Watt PA Circuit Diagram 5.1.5.5 Drg. Nō. 12-001870C1, 5W PA Component List(1) PBL UHF1/1A 1 & 2 Air Interface Maintenance Handbook H/book Number:-60-055900HBKM Issue No:-2 Date:-20/10/2003 Page:-48 of 85 5.1.5.6 Drg. Nō. 12-001870C2, 5W PA Component List(2) PBL UHF1/1A 1 & 2 Air Interface Maintenance Handbook H/book Number:-60-055900HBKM Issue No:-2 Date:-20/10/2003 Page:-49 of 85 5.1.5.7 Drg. Nō. 80-008450, Power Amplifier/Alarm Board DC Wiring Details PBL UHF1/1A 1 & 2 Air Interface Maintenance Handbook H/book Number:-60-055900HBKM Issue No:-2 Date:-20/10/2003 Page:-50 of 85 5.1.6 5.1.6.1 3 Stage Amplifier Alarm Boards (12-002201) Description Amplifier Alarm Boards are fitted to monitor the bias conditions of AFL Class A amplifiers which remain constant in normal operation. Any departure from normal bias conditions is a result of device failure, excess temperature, over-driving or oscillation (excessive power). In normal operation, the Class A bias circuit of the amplifier develops a constant voltage of 1.20V across the collector current setting resistor. The Amplifier Alarm Board is a window comparator device, which is adjusted to sense a departure from this condition. Several different alarm outputs are provided to simplify interfacing, (Relay Contact, Open Collector, and TTL Logic Levels) The basic version of the Alarm Board (12-002801) monitors a single amplifier stage. A three-stage version (12-002201) is used on complex amplifiers where three separate comparators have their outputs logically combined to a common output stage. Failure of any one stage will activate the alarms. Note that the alarm board has a green Light Emitting Diode located near to the centre of the printed circuit board, which is illuminated on ‘Good’, and extinguished on ‘Alarm’. It is therefore a simple matter to identify an active module failure, by searching for an Alarm Board which has its green LED extinguished. A simple test of the alarm board is possible by shorting across the monitor inputs, pins 1 and 2, 3 and 4 or across pins 5 and 6. This last monitor input is inactive if the board has been converted to a two way alarm board. (Refer to relevant amplifier alarm wiring diagram.) 1) 2) 3) Volt-free change over relay contacts. Open collector NPN transistor pulls low on alarm. TTL driver. The use of precision voltage sources and resistors has eliminated the need for initial adjustment or calibration, and the board will function correctly with a wide variation in power supply voltage (8 to 30 volts, nominal supply is 12 or 24Volts). There are two selectable link options on the three-way board: LINK1 - Removed to convert to two-way alarm board. LINK2 - Removed to isolate 0V from chassis earth. The one way alarm board only has the 0V isolation link (LINK2) fitted. PBL UHF1/1A 1 & 2 Air Interface Maintenance Handbook H/book Number:-60-055900HBKM Issue No:-2 Date:-20/10/2003 Page:-51 of 85 5.1.6.2 Technical Specification PARAMETER SPECIFICATION Operating voltage: 8 to 30V (floating earth) Alarm Threshold: Vcc - 1.20 volt +15% Alarm output relay contacts: Max. switch current: 1.0Amp Max. switch volts: 120Vdc/60VA Max. switch power: 24W/60VA Min. switch load: 10.0µA/10.0mV Relay isolation: 1.5kV Mechanical life: >2x107 operations Relay approval: BT type 56 Connector details: 15-way 0.1" pitch operational: :-10°C to +55°C Temperature range: storage: :-40°C to +70°C 74 x 56mm (3 stage) PCB Size: 54 x 56mm (1 stage) PBL UHF1/1A 1 & 2 Air Interface Maintenance Handbook H/book Number:-60-055900HBKM Issue No:-2 Date:-20/10/2003 Page:-52 of 85 5.1.6.3 Drg. Nō. 12-002201, 3 Stage Alarm Board Assembly Drawing & Parts List PBL UHF1/1A 1 & 2 Air Interface Maintenance Handbook H/book Number:-60-055900HBKM Issue No:-2 Date:-20/10/2003 Page:-53 of 85 H/book Number:-60-055900HBKM Issue No:-2 Date:-20/10/2003 PBL UHF1/1A 1 & 2 Air Interface Maintenance Handbook Page:-54 of 85 D1 1.23v S R12D C1 1uF R2 120R R1 1K 8 I C3 IC2 IC1 , IC2 & IC3 = LM324A M A LL DIODE S = LL4148 UNLE SS MARK E D OTHE RWIS E R4 3K 6 R3 120R HI CON N R6 100K CON N R5 100K R7 100K LOW IC3 11 R8 100K C2 100n R11 1K VCC +7. 5v 0v 10 I C3 R12 13 12 270K R9 1K +7. 5v IC3 270K R10 14 No HI R13 100K IS S UE D E S C R I P TI ON CR0508 P RODUCTION I S S UE P RODUCTION I S S UE 2A 4K 7 R42 D3 D2 C7 1u R14 100K MONITOR 2 I NP UT LOW R15 100K D A TE 14/1/94 11/ 9/ 93 29/8/00 CON N MONITOR 1 INP UT CON N I C2 BY MRB MRB MNR RB I C1 RB 11/ 8/ 93 APPD D A TE C3 100n 10 A LL D I ME N S I ON S A R E I N mm U N LE S S OTH E R WI S E S TA TE D CHK D MRB D R A WN 11 100K R16 10 10 R20 IC2 270K IC2 270K 13 12 R18 4K 7 R29 V CC +7.5v 14 12 R30 2K2 D5 D4 11 N O D E C I MA L P LA C E ± 1mm ON E D E C I MA L P LA C E ± 0. 3mm TWO D E C I MA L P LA C E S ± 0. 1mm TOLE R A N C E S B Y A E R I A L FA C I LI TI E S LTD . 12 S C A LE N.T.S TH I S I S A P R OP R I E TA R Y D E S I GN OF A E R I A L FA C I LI TI E S LTD . R E P R OD U C TI ON OR U S E OF TH I S D E S I GN B Y OTH E R S I S P E R MI S S I B LE ON LY I F E X P R E S S LY A U TH OR I S E D I N WR I TI N G R19 1K R17 1K 11 R21 100K HI 13 RL2/ 2 NOT US E D B CW71 R22 100K MONI TOR 3 INP UT TR1 13 CON N CON N R23 100K RE L RL1 D8 +7.5v I C1 LED1 14 Tel : 01494 777000 Fax : 01494 777002 Aerial Facilities Limited England LOW 14 11 15 C8 1. 0 R27 1K RL1/2 BCW71 TR2 R25 1K 0v R36 3K V CC 10 13 12 R26 IC1 270K R34 4K7 R33 10K IC1 270K R28 TR4 B CW71 R38 1K R37 2K4 16 0v 1K R35 CONN CONN CONN B CW71 TR3 OP A MP 10 14 TR4 D7 D6 R40 LK2 D9 3v3 16 D R A WI N G N o CIRCUIT DIAGRAM 15 0V CONN A LARM 0v 14 CONN O/ C A LA RM 13 CONN +5v TTL IN 12 CONN 12-002270 17 R41 22K TTL A LA RM 11 CONN A LA RM CONTA CTS 2K 2 FZT751 BCW71 R39 560R TR6 17 3 STAGE AMPLIFIER ALARM BOARD C U S TOME R TI TLE R32 4K 7 R31 10K R24 100K C4 100n 15 LK 1 18 C6 100n +8v TO +30v 7 CONN 18 5.1.6.4 Drg. Nō. 12-002270, 3 Stage Alarm Board Circuit Diagram 5.1.6.5 Generic Wall Enclosure Alarm Wiring Sketch PBL UHF1/1A 1 & 2 Air Interface Maintenance Handbook H/book Number:-60-055900HBKM Issue No:-2 Date:-20/10/2003 Page:-55 of 85 5.1.7 5.1.7.1 DC/DC Converter, 24V in, 12V 8A out (13-003011) Description The DC/DC converter fitted is an AFL assembled, high power PCB unit with an 8 amp @ 12V output capability. The circuit is basically an O.E.M semiconductor regulator (one side of which has a heatsink mounting plate, that is usually bolted to the casing of a Cell Enhancer) and smoothing components built onto a printed circuit board with screw block terminations. Note: no circuit diagram of the O.E.M. regulator is available. This unit should not be repaired, only replaced. 5.1.7.2 Technical Specification PARAMETER Input Voltage Range: Output Voltage: Max. Current Load: Temperature Operation: Range: Storage: Size(PCB): Weight (Loaded PCB): SPECIFICATION 18-28V DC 12V±0.5V 8.0Amps -10°C to +55°C -40°C to +70°C 190 x 63mm 291gms PBL UHF1/1A 1 & 2 Air Interface Maintenance Handbook H/book Number:-60-055900HBKM Issue No:-2 Date:-20/10/2003 Page:-56 of 85 5.1.8 5.1.8.1 Channel Selective & Channel Control Modules (17-003012 & 17-002101) Channel Selective Module Description The channel selectivity module is employed when the Cell Enhancer requirement dictates that very narrow bandwidths (single operating channels), must be selected from within the operating passband. One channel selectivity module is required for each channel. The Channel Selectivity Module is an Up/Down frequency converter that mixes the incoming channel frequency with a synthesised local oscillator, so that it is down-converted to an Intermediate Frequency (IF) in the upper HF range. An eight pole crystal filter in the IF amplifier provides the required selectivity to define the operating passband of the Cell Enhancer to a single PMR channel. The same local oscillator then converts the selected IF signal back to the channel frequency. Selectivity is obtained from a fixed bandwidth block filter operating at an intermediate frequency (IF) in the low VHF range. This filter may be internal to the channel selectivity module (Crystal or SAW filter) or an externally mounted bandpass filter, (LC or Helical Resonator). Various IF bandwidths can therefore be accommodated. A synthesized Local Oscillator is employed in conjunction with high performance frequency mixers, to translate between the signal frequency and IF. The operating frequency of each channel selectivity module is set by the programming of channel selectivity module frequencies and is achieved digitally, via hard wired links, banks of DIP switches, or via an onboard RS232 control module, providing the ability to remotely set channel frequencies. Automatic Level Control (ALC) is provided within each channel selectivity module such that the output level is held constant for high level input signals. This feature prevents saturation of the output mixer and of the associated amplifiers. Alarms within the module inhibit the channel if the synthesised frequency is not locked. The synthesiser will not usually go out of lock unless a frequency far out of band is programmed. The channel selectivity module is extremely complex and, with the exception of channel frequency programming within the design bandwidth, it cannot be adjusted or repaired without extensive laboratory facilities and the necessary specialised personnel. If a fault is suspected with any channel selectivity module it should be tested by substitution and the complete, suspect module should then be returned to AFL for investigation. PBL UHF1/1A 1 & 2 Air Interface Maintenance Handbook H/book Number:-60-055900HBKM Issue No:-2 Date:-20/10/2003 Page:-57 of 85 5.1.8.2 Drg. Nō. 17-003080, Generic Channel Module Block Diagram PBL UHF1/1A 1 & 2 Air Interface Maintenance Handbook H/book Number:-60-055900HBKM Issue No:-2 Date:-20/10/2003 Page:-58 of 85 5.1.8.3 Channel Selectivity Control Module Description The control module consists of a bank of four, in-line data switches each of which control one channel module frequency setting. One controller can therefore control four channel modules. The following list shows the frequencies available for each switch setting. 5.1.8.4 IDC PIN 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 Channel Controller DIP Switch Configuration Frequencies 25-way Connector 13 25 12 24 11 23 10 22 21 20 19 18 17 16 15 14 --- Function Freq. bit 1 (12.5kHz) Freq. bit 2 (25kHz) Freq. bit 3 (50kHz) Freq. bit 4 (100kHz) Freq. bit 5 (200kHz) Freq. bit 6 (400kHz) Freq. bit 7 (800kHz) Freq. bit 8 (1.6MHz) Freq. bit 9 (3.2MHz) Freq. bit 10 (6.4MHz) Freq. bit 11 (12.8MHz) Freq. bit 12 (25.6MHz) Freq. bit 13 (51.2MHz) Freq. bit 14 (102.4MHz) Freq. bit 15 (204.8MHz) Freq. bit 16 (409.6MHz) Module alarm Gain bit 1 Gain bit 2 Gain bit 3 Gain bit 4 +5V 0V Switched 12V 0V --- PBL UHF1/1A 1 & 2 Air Interface Maintenance Handbook H/book Number:-60-055900HBKM Issue No:-2 Date:-20/10/2003 Page:-59 of 85 5.1.8.5 UHF1 Downlink Channel Module Configuration Table Setting Frequency Gain ALC DIP (off) Nō.’s B/W 5.1.8.6 D/L(2) 470.2625MHz 20dB -23dB 1,3,7,11,12,16 15KHz D/L(3) 470.2125MHz 20dB -23dB 1,7,11,12,16 15KHz UHF1 Uplink Channel Module Configuration Table Setting Frequency Gain ALC DIP (off) Nō.’s B/W 5.1.8.7 D/L(1) 482.2375MHz 15dB -23dB 1,2,13,16 15KHz U/L(1) 473.2625MHz 5dB -22dBm 1,3,5,6,9,11,12,16 30KHz U/L(2) 470.2125MHz 5dB -22dBm 1,5,6,9,11,12,16 30KHz U/L(3) 485.2375MHz 15dB -12dBm 1,2,5,6,7,8,13,16 30KHz UHF1A Downlink Channel Module Configuration Table Setting Frequency Gain ALC DIP (off) Nō.’s B/W D/L(1) D/L(2) 470.0875MHz 470.1375MHz 20dB 20dB -23dB -23dB 1,2,3,5,6,11,12,16 1,2,4,5,6,11,12,16 15KHz 15KHz D/L(3) 470.3625MHz 20dB -23dB 1,3,4,7,11,12,16 15KHz PBL UHF1/1A 1 & 2 Air Interface Maintenance Handbook H/book Number:-60-055900HBKM Issue No:-2 Date:-20/10/2003 Page:-60 of 85 5.1.8.8 UHF1A Uplink Channel Module Configuration Table Setting Frequency Gain ALC DIP (off) Nō.’s B/W 5.1.8.9 Setting Frequency Gain ALC DIP (off) Nō.’s B/W 5.1.8.10 Setting Frequency Gain ALC DIP (off) Nō.’s B/W D/L(1) D/L(2) D/L(3) 473.0875MHz 473.1375MHz 473.3625MHz 15dB 15dB 15dB -32dB -32dB -32dB 1,2,3,6,9,11,12,16 1,2,4,6,9,11,12,16 1,3,4,5,6,9,11,12,16 15KHz 15KHz 15KHz UHF2 Downlink Channel Module Configuration Table D/L(1) 483.3125MHz 20dB -35dBm 1,4,5,7,13,16 15KHz D/L(2) 483.2875MHz 20dB -35dBm 1,2,3,5,7,13,16 15KHz D/L(3) 483.0625MHz 20dB -35dBm 1,3,7,13,16 15KHz D/L(4) 483.5265MHz 20dB -35dBm 1,3,4,6,7,13,16 15KHz UHF2 Uplink Channel Module Configuration Table D/L(1) 486.3125MHz 6dB -20dBm 1,4,7,9,13,16 15KHz D/L(2) 486.2875MHz 6dB -20dBm 1,2,3,7,9,13,16 15KHz D/L(3) 486.0625MHz 6dB -20dBm 1,3,5,6,9,13,16 15KHz D/L(4) 486.5265MHz 6dB -20dBm 1,3,4,5,7,9,13,16 15KHz PBL UHF1/1A 1 & 2 Air Interface Maintenance Handbook H/book Number:-60-055900HBKM Issue No:-2 Date:-20/10/2003 Page:-61 of 85 5.1.9 5.1.9.1 Single & Dual 24Volt Relay Boards (20-001602 & 80-008902) 24V Relay Boards (20-001602 & 80-008902) Description The General Purpose Dual Relay Board (20-001602) allows the inversion of signals and the isolation of circuits. It is equipped with two dual pole change-over relays RL1 and RL2, with completely isolated wiring, accessed via screw terminals. Both relays are provided with polarity protection diodes and diodes for suppressing the transients caused by "flywheel effect" which can destroy switching transistors or induce spikes on neighbouring circuits. It’s common use is to amalgamate all the alarm signals into one, volts-free relay contact pair for the main alarm system. Note that the board is available for different voltages (12 or 24V) depending on the type of relays fitted at RL1 and RL2. The single relay board (80-008902) is electrically identical to the dual version but is proportionately smaller in size. It also has a single in-line IDC connector in place of the screw terminal blocks of the dual model and performs similar summary alarm functions. PBL UHF1/1A 1 & 2 Air Interface Maintenance Handbook H/book Number:-60-055900HBKM Issue No:-2 Date:-20/10/2003 Page:-62 of 85 5.1.9.2 Drg. Nō. 20-001602, Dual 24V Relay Board Assembly Drawing PBL UHF1/1A 1 & 2 Air Interface Maintenance Handbook H/book Number:-60-055900HBKM Issue No:-2 Date:-20/10/2003 Page:-63 of 85 5.1.9.3 Drg. Nō. 20-001671, Dual 24V Relay Board Circuit Diagram PBL UHF1/1A 1 & 2 Air Interface Maintenance Handbook H/book Number:-60-055900HBKM Issue No:-2 Date:-20/10/2003 Page:-64 of 85 5.1.9.4 Drg. Nō. 80-008970, Single Relay Board Circuit Diagram PBL UHF1/1A 1 & 2 Air Interface Maintenance Handbook H/book Number:-60-055900HBKM Issue No:-2 Date:-20/10/2003 Page:-65 of 85 5.1.10 SMA coaxial termination (93-930003) 5.1.10.1 Description When a combiner system is used to split or combine RF signals, in many cases it is most cost effective to use a standard stock item 4, 6 or 8 port device where, in fact, only a 3 - 6 port device is needed. In this case the splitter/combiner module has one of its ports terminated (both uplink & downlink) with an appropriate load in order to preserve the correct impedance of the device over the specified frequency range. This has the advantage of allowing future expansion capability should extra channels or other functions become necessary. Terminations are available for every type of RF connector that may be used, N type, 7/16th or SMA, in this case SMA. 5.1.11 24V 400W Flat-Pack Power Supply (96-300011) 5.1.11.1 Description The power supply unit is a switched-mode type capable of supplying 24V DC at 16.0Amps continuously. Equipment of this type typically requires approximately 10.0 Amps at 24V DC, so the PSU will be used conservatively ensuring a long operational lifetime. No routine maintenance of the PSU is required. If a fault is suspected, then the output voltage from the power supply may be measured on its output terminals. This is typically set to 24.5V. All the PSU’s used in AFL Cell Enhancers are capable of operation from either 110 or 220V nominal AC supplies. The line voltage is sensed automatically, so no adjustment or link setting is needed by the operator. No drawings of the PSU are available. 5.1.11.2 Technical Specification AC Input Supply: Voltage: 110 or 220V nominal - 90 to 132 or 180 to 264V (single phase, absolute limits) Frequency: 47 to 63Hz DC Output Supply: Voltage: 24V DC (nominal), 22 to 26V (absolute limits) Current: 16.0A Temperature operational: -10ΒC to +55ΒC range: storage: -40ΒC to +70ΒC PBL UHF1/1A 1 & 2 Air Interface Maintenance Handbook H/book Number:-60-055900HBKM Issue No:-2 Date:-20/10/2003 Page:-66 of 85 5.2 UHF 2 Air Interface (60-055902) 5.2.1 Bandpass Filter (02-013401) See section 5.1.1 5.2.2 4 Port Tx Hybrid Combiner (05-003019) 5.2.2.1 Description The 3dB Hybrid Combiner used is a device for accurately matching two or more RF signals to single or multiple ports, whilst maintaining an accurate 50Ω load to all inputs/outputs and ensuring that the VSWR and insertion losses are kept to a minimum. Any unused ports will be terminated with an appropriate 50Ω load. In UHF 2 this hybrid is used to combine the signals from the channel selective modules (from both UHF 1 & 2) in the downlink direction for onward transmission by fibre, and similar signals for both UHF 1 & 2 are combined before being further split into the uplink channel modules. 5.2.2.2 Technical Specification PARAMETER Frequency Range: Bandwidth: Inputs: Outputs: Insertion Loss: Isolation between Input or Output ports: Return Loss (VSWR) – Input: Return Loss (VSWR) – Output: Impedance: operation: Temperature Range storage: MTBF: Power Rating – Splitter: Power Rating – Combiner: Environmental: Connectors: Dimensions: Weight: SPECIFICATION ƒo ± 10% (50 – 500 MHz) ƒo ± 10% <3.5 dB >27 dB 1.3:1 1.3:1 50 Ω -10°C to +55°C -20°C to +70°C >180,000 hours Up to 150 Watts (load dependant) Available up to 100 Watts IP54 ‘N’ female 118 x 102 x 35 mm (including connectors) 0.5 kg PBL UHF1/1A 1 & 2 Air Interface Maintenance Handbook H/book Number:-60-055900HBKM Issue No:-2 Date:-20/10/2003 Page:-67 of 85 5.2.3 Four Way Low Power Splitter (05-003401) See section 5.1.2 5.2.4 ¼Watt 0- -30dB Switched Attenuator (10-000701) See section 5.1.3 5.2.5 Low Noise Amplifiers (11-007302 & 11-007402) See section 5.1.4 5.2.6 3 Stage Amplifier Alarm Boards (12-002201) See section 5.1.6 5.2.7 20Watt Power Amplifier (12-004201) 5.2.7.1 Description The power amplifiers fitted to this unit are multi-stage, solid state power amplifiers. Class A circuitry is employed throughout the units to ensure excellent linearity over a wide dynamic frequency range. All the semi-conductor devices are very conservatively rated to ensure low device junction temperatures and a long, trouble free working lifetime. The power amplifiers should require no maintenance over their operating lives. Under no circumstances should the cover be removed or the side adjustments disturbed unless it is certain that an amplifier has failed; since they are critically aligned during manufacture and any re-alignment will require extensive test equipment. 5.2.7.2 Technical Specification PARAMETER Frequency Range: Bandwidth: Maximum Output Power: Gain: 1dB Compression Point: 3rd Order Intercept Point: VSWR: Connectors: Supply: Size: Weight: Temperature operational: range: storage: SPECIFICATION 350 – 550MHz (tuned to spec.) 20MHz (tuned to spec.) >20W 30dB <+43dBm <+54dBm better than 1.45:1 SMA female 3.50A @ 24V DC 276 x 78 x 40mm (ex. connectors & heatsink) 1.5 kg (approximately, excluding heatsink) -10°C to +55°C -40°C to +70°C PBL UHF1/1A 1 & 2 Air Interface Maintenance Handbook H/book Number:-60-055900HBKM Issue No:-2 Date:-20/10/2003 Page:-68 of 85 5.2.7.3 Drg. Nō. 12-004201, PA General Assembly PBL UHF1/1A 1 & 2 Air Interface Maintenance Handbook H/book Number:-60-055900HBKM Issue No:-2 Date:-20/10/2003 Page:-69 of 85 H/book Number:-60-055900HBKM Issue No:-2 Date:-20/10/2003 RF INPUT C8 220pF C1 56pF C3 1uF C2 1-14pF FB1 IN REG.1 LM337T C4 1-14pF C5 47pF R1 1R2 C6 47pF C7 1nF TR1 TP5012 ARE 50 ohm STRIPLINES L2 1uH L1 OUT ADJ FB2 C10 1-14pF L3 R2 1KR ALARM REF R3 470R CHKD PBL UHF1/1A 1 & 2 Air Interface Maintenance Handbook Page:-70 of 85 APPD BB 3/8/98 DATE ALL DIMENSIONS ARE IN mm UNLESS OTHERWISE STATED GB DBS DRAWN NO DECIMAL PLACE ± 1mm ONE DECIMAL PLACE ± 0.3mm TWO DECIMAL PLACES ± 0.1mm TOLERANCES SCALE THIS IS A PROPRIETARY DESIGN OF AERIAL FACILITIES LTD. REPRODUCTION OR USE OF THIS DESIGN BY OTHERS IS PERMISSIBLE ONLY IF EXPRESSLY AUTHORISED IN WRITING BY AERIAL FACILITIES LTD. REFER TO 12-004211 FOR COMPONENT POSITIONS EXCEPT FOR THOSE MARKED (THEY ARE SPECIFIED ON 12-004201) CONDUCTORS SHOWN THUS: C9 1uF C11 1-14pF C12 56pF ALARM DET.1 C14 4.7uF C13 1-14pF C28 18pF L4 OUT C15 1-14pF IN C29 18pF C20 1uF R5 R47 C16 27pF C17 27pF Tel: (01494) 777000 Fax (01494)777002 C21 56pF C19 56pF D1 2OCTQ45 Aerial Facilities Limited England FB3 REG.2 LM337T ADJ +24v C30 1000pF C18 1uF No 1A 1B FB4 ISSUE DESCRIPTION CUSTOMER DRAWING.No CIRCUIT DIAGRAM 12-004270 DATE 3/8/98 C26 1-14pF BY PDC DBS RF OUTPUT 16/5/00 C25 1-14pF C27 56pF PRODUCTION ISSUE C24 15pF C23 15pF ALARM DET.2 CR1679 C22 1-14pF L5 R4 1KR POWER AMPLIFIER 450MHz 10/20W CLASS A TITLE TR2 PTB20031 C31 1nF 5.2.7.4 Drg. Nō. 12-004270, PA Circuit Diagram 5.2.7.5 CIRC. REF. Drg. Nō. 12-004270C1, PA Parts List(1) C1 93-200006 56pF CHIP CAP 10% TOL.(MIN) C2 93-130023 PCB MOUNT AIR TRIMMER 1-14pF C3 93-240003 1uF TANTALUM CHIP CAP 35V C4 93-130023 PCB MOUNT AIR TRIMMER 1-14pF C5 REFER TO GA 12-004201 FOR DETAILS C6 REFER TO GA 12-004201 FOR DETAILS C7 93-200020 1nF CHIP CAP 63V 10% C8 93-200014 220pF CHIP CAP 10% TOL (MIN) C9 93-240004 1uF TANTALUM CHIP CAP 35V NOT FITTED NOT FITTED C11 93-130023 PCB MOUNT AIR TRIMMER 1-14pF C12 93-200006 56pF CHIP CAP 10% TOL.(MIN) C13 93-130023 PCB MOUNT AIR TRIMMER 1-14pF C C14 93-240006 4.7uF TANTALUM CHIP CAP 35V C15 93-130023 PCB MOUNT AIR TRIMMER 1-14pF C16 REFER TO GA 12-004201 FOR DETAILS DESCRIPT ION AFL ST OCK REF. C10 C17 REFER TO GA 12-004201 FOR DETAILS C18 93-240003 1uF TANTALUM CHIP CAP 35V C19 93-200006 56pF CHIP CAP 10% TOL.(MIN) C20 93-240004 1uF TANTALUM CHIP CAP 35V C21 93-200006 56pF CHIP CAP 10% TOL.(MIN) C22 93-130023 PCB MOUNT AIR TRIMMER 1-14pF C23 93-200005 15pF CHIP CAP 10% TOL.(MIN) C24 93-200005 15pF CHIP CAP 10% TOL.(MIN) C25 93-130023 PCB MOUNT AIR TRIMMER 1-14pF C26 93-130023 PCB MOUNT AIR TRIMMER 1-14pF C27 93-200006 56pF CHIP CAP 10% TOL.(MIN) C28 93-200004 18pF CHIP CAP 10% TOL.(MIN) C29 93-200004 18pF CHIP CAP 10% TOL.(MIN) C30 93-200016 1000pF (1nF) CHIP CAP 10% TOL.(MIN) C31 REFER TO GA 12-004201 FOR DETAILS 2A 5/5/00 CR1679 1A 5/8/98 PROD. ISS. DAT E ISSUE CHANGE No ISSUE DAT E CHANGE No ISSUE DAT E CHANGE No ISSUE DAT E CHANGE No TITLE POWER AMPLIFIER,450MHz,10/20W Aerial Facilities Limited DRAWN DATE PDC 5/8/98 CIRCUIT COMPONENT LIST APPD CHKD GB CUSTOMER BB COMPONENT LIST FOR 12-004270C1 PBL UHF1/1A 1 & 2 Air Interface Maintenance Handbook H/book Number:-60-055900HBKM Issue No:-2 Date:-20/10/2003 Page:-71 of 85 5.2.7.6 CIRC. REF. Drg. Nō. 12-004270C2, PA Parts List(2) DESCRIPT ION AFL ST OCK REF. TR1 REFER TO GA 12-004201 FOR DETAILS TR2 REFER TO GA 12-004201 FOR DETAILS REG1 94-300002 LM337T, VOLTAGE REGULATOR REG2 94-300002 LM337T, VOLTAGE REGULATOR D1 94-120006 2OTQ45 45V DUAL SCHOTTKY DIODE R1 93-540075 1R2 2.5W RESISTOR R2 93-630037 1KR CHIP RESISTOR R3 93-630032 470R CHIP RESISTOR R4 93-630037 1KR CHIP RESISTOR R5 93-540083 47R 6W RESISTOR L1 90-500012 93-910001 1.25 ENAMELLED COPPER WIRE FERRITE BEAD L2 93-400004 1.0uH CHOKE SIGMA SC10 SERIES L3 90-500012 93-910001 1.25 ENAMELLED COPPER WIRE FERRITE BEAD 90-500012 1.25 ENAMELLED COPPER WIRE 93-910001 FERRITE BEAD 90-500012 1.25 ENAMELLED COPPER WIRE 93-910001 FERRITE BEAD L4 L5 2A 5/5/00 CR1679 1A 5/8/98 PROD. ISS. DAT E ISSUE CHANGE No ISSUE DAT E CHANGE No ISSUE DAT E CHANGE No ISSUE DAT E CHANGE No TITLE POWER AMPLIFIER,450MHz,10\20W Aerial Facilities Limited DRAWN DATE PDC 5/8/98 CIRCUIT COMPONENT LIST APPD CHKD GB CUSTOMER COMPONENT LIST FOR BB 12-004270C2 PBL UHF1/1A 1 & 2 Air Interface Maintenance Handbook H/book Number:-60-055900HBKM Issue No:-2 Date:-20/10/2003 Page:-72 of 85 5.2.7.7 Drg. Nō. 12-003670, PA to Alarm Wiring Details PBL UHF1/1A 1 & 2 Air Interface Maintenance Handbook H/book Number:-60-055900HBKM Issue No:-2 Date:-20/10/2003 Page:-73 of 85 5.2.8 DC/DC Converter, 24V in, 12V 8A out (13-003011) See section 5.1.7 5.2.9 Chan. Selec. & Chan. Contr. Mdls (17-003012 & 17-002101) See section 5.1.8 5.2.10 21MHz IF Filter Board (17-002502) 5.2.10.1 Description The above channel selective modules are fitted with a 21MHz filter board to narrow the channel bandwidth from 30kHz to 15kHz. 5.2.11 Single & Dual 24Volt Relay Boards (20-001602 & 80-008902) See section 5.1.9 5.2.12 SMA Coaxial Termination (93-930003) See section 5.1.10 5.2.13 24V 400W Flat-Pack Power Supply (96-300011) See section 5.1.11 5.2.14 JWS75-15/A PSU (96-300045) 5.2.14.1 Description The power supply unit is a switched-mode type capable of supplying 24V DC at 6.25Amps continuously. This PSU is used to provide power for the fibre optic modules which will typically require approximately 3.0 Amps at 24V DC, so the PSU will be used conservatively ensuring a long operational lifetime. No routine maintenance of the PSU is required. If a fault is suspected, then the output voltage from the power supply may be measured on its output terminals. This is typically set to 24.5V. All the PSU’s used in AFL Cell Enhancers are capable of operation from either 110 or 220V nominal AC supplies. The line voltage is sensed automatically, so no adjustment or link setting is needed by the operator. 5.2.14.2 Technical Specification Voltage: Frequency: Voltage: Current: AC Input Supply: 110 or 220V nominal 90 to 132 or 180 to 264V (absolute limits) 47 to 63Hz DC Output Supply: 24V DC (nominal) 22 to 26V (absolute limits) 6.25A PBL UHF1/1A 1 & 2 Air Interface Maintenance Handbook H/book Number:-60-055900HBKM Issue No:-2 Date:-20/10/2003 Page:-74 of 85 5.2.15 Single Mode Optical Coupler (98-100001) 5.2.15.1 Description Single or dual optical couplers are used whenever it is required to split optical signals for transmission to more than one destination or combine them to a single common input. The couplers are O.E.M devices and are not considered repairable. Any suspected faulty coupler should be replaced. 5.2.16. Fibre Optic Receiver & Transmitter (98-200003 & 98-300003) 5.2.16.1 Description The F/O units consist of a receiver & transmitter, which modulates the RF signal onto a laser carrier and transmits it via fibre/optic cable to a receiver unit some distance away where it is demodulated back to the original RF signal with very small values of accrued attenuation. Both transmitter and receiver modules have their own dedicated alarm outputs (volt-free relay contacts) which are integrated into the main alarm system. Being O.E.M devices, no drawings or circuit diagrams are available. Caution: The FO units are NOT weather proof. PBL UHF1/1A 1 & 2 Air Interface Maintenance Handbook H/book Number:-60-055900HBKM Issue No:-2 Date:-20/10/2003 Page:-75 of 85 5.2.16.2 Technical Specification PARAMETER Tx: Power Consumption: Rx: Frequency Range: Link noise figure: Link noise figure (max.): Total link gain: @30KHz B/W: CNR @ 5 Km link length: @200KHz B/W: @1.2MHz B/W: RF total input power: Input IP3: Optical budget: Max. link length: Response Flatness: Optical Output Power (Tx): Optical Wavelength: Fibre loss: Optical return loss: Optical Connector loss: SPECIFICATION 120mA @ 15V DC (320mA @ -10ΒC) 330mA @ 15V DC 0.1 – 2.2GHz 40dB (typical) <45dB 0dB >84dB >76dB >69dB 0dBm 26dBm 2 – 9.0dB 20Km <±1.0 dB 2.4 – 4.0mW 1310±10nm 0.38dB/Km -60dB 0.5dB per mated pair Rx ‘D’ Type Female Connector Pin Nō. Signal Description +15V DC Power Optional Data Output Power Ground RF Signal Strength Monitor Optical Power Monitor O.C. Alarm Optional Data Output Relay Alarm Contact 1 Relay Alarm Contact 2 Tx ‘D’ Type Female Connector Pin Nō. Signal Description +15V DC Power Optional Data Input Power Ground RF Signal Strength Monitor Laser Photodiode Current Monitor Laser Current Monitor Optional Data Input Relay Alarm Contact 1 Relay Alarm Contact 2 PBL UHF1/1A 1 & 2 Air Interface Maintenance Handbook H/book Number:-60-055900HBKM Issue No:-2 Date:-20/10/2003 Page:-76 of 85 5.3 UHF1A 60-055903 470MHz 3 Channel BDA There are no modules or components in UHF1A unit that have not been covered in earlier section of this document – see the tables in 3. SPECIFICATIONS for channel module frequencies, and the diagrams in section 4. SYSTEM DRAWINGS for expected signal levels. PBL UHF1/1A 1 & 2 Air Interface Maintenance Handbook H/book Number:-60-055900HBKM Issue No:-2 Date:-20/10/2003 Page:-77 of 85 6. INSTALLATION 6.1 Initial Installation Record When this equipment is initially commissioned, please use the equipment set-up record sheet in Appendix A. This will help both the installation personnel and AFL should these figures be needed for future reference or diagnosis. 6.2 General The size and weight of the wall units mean that they represent a significant health hazard unless they are mechanically installed in the correct manner. In the interests of safety this should be done before any electrical, RF, or optical connections are made. It is important in determining the location of the wall units that space is allowed for access to the front and underneath of the equipment. To enable maintenance to be carried out, the door must be able to fully open. The location must be served with a duct to allow the entry of cables into the unit. 6.3 Electrical Connections The mains power supply and the alarms are connected through an IP65 connector which should need no further attention once connected. It is recommended that the AC power connection is approved by a qualified electrician, who must satisfy himself that the supply will be the correct voltage and of sufficient capacity. All electrical and RF connection should be completed and checked prior to power being applied for the first time. 6.4 Optical Connections The optical input and output ports are be located on a bracket fixed to the lower inside of the case. The optical fibres from the tunnels enter through a cable gland on the case underside The ports are supplied with a green plastic cover, which must be removed prior to the connection of the fibre cable. Ensure that transmitter and receiver fibre cable are identified to prevent misconnection. At the master site, the fibre transmitters are in the downlink path with the receivers in the uplink. At the remote sites the fibre transmitters are in the uplink with the receivers in the downlink. Where some of the fibre optic transmitter outputs are split with optical couplers to provide a connection to more than one remote site, care must be taken to ensure that the correct connections are made. Ensure that connections are kept clean and are fully tightened. PBL UHF1/1A 1 & 2 Air Interface Maintenance Handbook H/book Number:-60-055900HBKM Issue No:-2 Date:-20/10/2003 Page:-78 of 85 6.5 RF Connections All RF connections are made to the cable termination, located on the right-hand side of the wall enclosure. Care must be taken to ensure that the correct connections are made with particular attention made to the base station TX/RX ports. In the event that the base transmitter is connected to the RX output of the rack, damage to the equipment may be done if the base station transmitter is then keyed. If the environment where the equipment is installed is deemed to be ‘wet’ i.e. water seepage through roofs or walls, then suitable methods to seal the RF N type connectors should be used, for example self amalgamating sealant tape. Ensure that connections are kept clean and are fully tightened. 6.6 Commissioning Once all connections are made the equipment is ready for commissioning. To commission the system the test equipment detailed in section 7.2 will be required. Using the system diagrams and the end-to-end test specification, the equipment should be tested to ensure correct operation. Typical RF levels that are not listed in the end-to-end specification, such as input levels to the fibre transmitters are detailed in the whole system diagram in section 4. On initial power up the system alarm indicators on the door of the equipment should be checked. A red LED illuminated indicates a fault and that particular module must be investigated before proceeding with the commissioning. A green LED illuminates, to indicate that the power supply is connected and valid. The individual fibre optic units are fitted with a pair of status indicators on their front panels. One is a green LED, which indicates that the unit is connected to a 15 Volt power supply. This indicator is common to both transmit and receive units. The second LED on the transmitter indicates that the laser is operating. On the receive unit the second LED indicates that a light signal is being received. When all the fibre connections are completed and power to each site is connected each fibre unit should show two illuminated indicators. In the event that any part of the system does not function correctly as expected, check all connections to ensure that they are to the correct port, that the interconnecting cables are not faulty and that they are tightened. The majority of commissioning difficulties arise from problems with the interconnecting cables and connectors. PBL UHF1/1A 1 & 2 Air Interface Maintenance Handbook H/book Number:-60-055900HBKM Issue No:-2 Date:-20/10/2003 Page:-79 of 85 7. MAINTENANCE 7.1 7.1.1 General Procedures Fault Finding In the event that the performance of the system is suspect, a methodical and logical approach to the problem will reveal the cause of the difficulty. The System consists of modules within a wall mounted, environmentally protected enclosure. Transmissions from the main base stations are passed though the system to the mobile radio equipment; this could be a handheld walkie-talkie, mobile telephone or a transceiver in a vehicle. This path is referred to as the downlink. The return signal path from the mobile radio equipment to the base station is referred to as the uplink. The first operation is to check the (optional) alarms of each of the active units and determine that the power supplies to the equipment are connected and active. This can be achieved remotely (via CEMS, the digital RS232 Cell Enhancer Management System, if fitted), or locally with the front door LED’s. The green LED on the front door should be illuminated, while the red alarm indicator should be off. If an Alarm is on, then that individual module must be removed and tested against the original test specification. The individual amplifier units have a green LED showing through a hole in their piggy-back alarm board (or directly through a hole in the amplifier lid), which is illuminated if the unit is working correctly. If an amplifier is suspect, check the DC power supply to the unit. If no other fault is apparent use a spectrum analyser to measure the incoming signal level at the input and then after reconnecting the amplifier input, measure the output level. Consult with the system diagram and amplifier specification to determine the expected gain and compare result. In the event that there are no alarms on and all units appear to be functioning it will be necessary to test the system in a logical manner to confirm correct operation. PBL UHF1/1A 1 & 2 Air Interface Maintenance Handbook H/book Number:-60-055900HBKM Issue No:-2 Date:-20/10/2003 Page:-80 of 85 7.1.2 Downlink Confirm that there is a signal at the expected frequency and strength from the base station. If this is not present then the fault may lay outside the system. To confirm this, inject a downlink frequency signal from a known source at the master site BTS input and check for output at the remote site feeder output. If a signal is not received at the output it will be necessary to follow the downlink path through the system to find a point at which the signal is lost. The expected downlink output for the given input can be found in the end-to-end test specification. 7.1.3 Uplink Testing the uplink involves a similar procedure to the downlink except that the frequencies used are those transmitted by the mobile equipment. 7.1.4 Fault repair Once a faulty component has been identified, a decision must be made on the appropriate course to carry out a repair. A competent engineer can quickly remedy typical faults such as faulty connections or cables. The exceptions to this are cable assemblies connecting bandpass filter assemblies that are manufactured to critical lengths to maintain a 50-ohm system. Care should be taken when replacing cables or connectors to ensure that items are of the correct specification. The repair of component modules such as amplifiers, tuned cavities or bandpass filters will not usually be possible in the field, as they frequently require specialist knowledge and test equipment to ensure correct operation. It is recommended that items of this type are replaced with a spare unit and the faulty unit returned to AFL for repair. If spare parts need to be ordered from AFL, be sure to quote the serial number of the Cell Enhancer/Repeater and the serial number [and frequencies] of the module(s) to be replaced. PBL UHF1/1A 1 & 2 Air Interface Maintenance Handbook H/book Number:-60-055900HBKM Issue No:-2 Date:-20/10/2003 Page:-81 of 85 7.1.5 Checking service Following the repair of any part of the system it is recommended that a full end-to-end test is carried out in accordance with the test specification and that the coverage is checked by survey. It is important to bear in mind that the system includes a radiating cable network and base stations that may be faulty or may have been damaged. 7.1.6 Service Support Advice and assistance with maintaining and servicing this system are available by contacting Aerial Facilities Ltd. 7.2 Tools & Test Equipment The minimum tools and test equipment needed to successfully service this AFL product are as follows:Spectrum analyser: Signal Generator: Attenuator: Test Antenna: Optical power meter: Digital multi-meter: Test cable x 2: Test cable x 2: Hand tools: 100kHz to 2GHz (Dynamic range = 90dB). 30MHz to 2GHz (-120dBm to 0dBm o/p level). 20dB, 10W, DC-2GHz, (N male – N female). Yagi or dipole for operating frequency. 1310 – 1550nM (-40 - +10dB) Universal Volt-Ohm-Amp meter. N male – N male, 2M long RG214. SMA male – N male, 1m long RG223. Philips #1&2 tip screwdriver. 3mm flat bladed screwdriver. SMA spanner and torque setter. PBL UHF1/1A 1 & 2 Air Interface Maintenance Handbook H/book Number:-60-055900HBKM Issue No:-2 Date:-20/10/2003 Page:-82 of 85 7.3 7.3.1 Care of Modules General Comments Many of the active modules contain semiconductor devices utilising MOS technology, which can be damaged by electrostatic discharge. Correct handling of such modules is mandatory to ensure their long-term reliability. To prevent damage to a module, it must be withdrawn/inserted with care. The module may have connectors on its underside, which might not be visible to the service operative. 7.3.2 Module Removal (LNA’s, general procedure): The following general rules should be followed to remove a module: Remove power to the unit Remove all visible connectors (RF, DC & alarm) Release module retaining screws. Slowly but firmly, pull the module straight out of its position. Take care not to twist/turn the module during withdrawal. (When the module is loose, care may be needed, as there may be concealed connections underneath). 7.3.3 Module Replacement (general): Carefully align the module into its location then slowly push the module directly straight into its position, taking care not to twist/turn it during insertion. Reconnect all connectors, RF, alarm, power etc.,(concealed connectors may have to be connected first). Replace retaining screws (if any). Double-check all connections before applying power. 7.3.4 Power Amplifiers 1) Remove power to the unit. (Switch off @ mains/battery, or remove DC in connector) 2) Remove alarm wires from alarm screw terminal block or disconnect multi-way alarm connector. 3) Carefully disconnect the RF input and output coaxial connectors (usually SMA) If alarm board removal is not required, go to step 5. 4) There is (usually) a plate attached to the alarm board which fixes it to the amplifier, remove its retaining screws and the alarm board can be withdrawn from the amplifier in its entirety. On certain types of amplifier the alarm board is not mounted on a dedicated mounting plate; in this case it will have to firstly be removed by unscrewing it from the mounting pillars, in most cases, the pillars will not have not have to be removed before lifting the amplifier. PBL UHF1/1A 1 & 2 Air Interface Maintenance Handbook H/book Number:-60-055900HBKM Issue No:-2 Date:-20/10/2003 Page:-83 of 85 5) If the amplifier to be removed has a heatsink attached, there may be several different ways it can have been assembled. The most commonly used method, is screws through the front of the heatsink to threaded screw holes (or nuts and bolts), into the amplifier within the main case. If the heatsink is mounted on the rear of the main case (e.g., against a wall in the case of wall mounted enclosures), then the fixing method for the heatsink will be from within the case, (otherwise the enclosure would have to be removed from the wall in order to remove the heatsink). When the heatsink has been removed, the amplifier may be unscrewed from the main casing by its four corner fixings and gently withdrawn. Fitting a new power amplifier module will be the exact reverse of the above. Note: Do not forget to apply fresh heatsink compound to the heatsink/main case joint and also between the amplifier and the main case. 7.3.5 Low Power Amplifier Replacement Disconnect the mains power supply and disconnect the 24V dc supply connector for the LPA. Disconnect the RF input and output cables from the LPA. Disconnect the alarm connector. Remove the alarm monitoring wires from (D type connector) pins 9 and 10. Remove the LPA module by removing the four retaining screws, replace with a new LPA module and secure it with the screws. Connect the RF cables to the LPA input and output connectors. Reconnect the wires to the alarm board connector pins 9 and 10. Reconnect the DC supply connector and turn the mains switch on. Note: Tighten SMA connectors using only a dedicated SMA torque spanner. If SMA connectors are over-tightened, irreparable damage will occur. . Do not use adjustable pliers to loosen/tighten SMA connectors. Also take care not to drop or knock the module as this can damage (or misalign in the case of tuned passive modules) sensitive internal components. Always store the modules in an environmentally friendly location 7.3.6 Module Transportation: To maintain the operation, performance and reliability of any module it must be stored and transported correctly. Any module not installed in a whole system must be kept in an antistatic bag or container. These bags or containers are normally identified by being pink or black, and are often marked with an ESD label. Any module sent back to AFL for investigation/repair must be so protected. Please contact AFL’s quality department before returning a module. PBL UHF1/1A 1 & 2 Air Interface Maintenance Handbook H/book Number:-60-055900HBKM Issue No:-2 Date:-20/10/2003 Page:-84 of 85 APPENDIX A INITIAL EQUIPMENT SET-UP CALCULATIONS GENERAL INFORMATION Client Name: AFL Equip. Model Nō. Site Name: Date: Model ANTENNA SYSTEMS Gain Azimuth Comments Type Loss Comments A - Service Antenna B – Donor Antenna Length C – Service Feeder D – Donor Feeder INITIAL PARAMETERS E – CE Output Power F – Antenna Isolation G – Input signal level from donor BTS Operating Voltage DOWNLINK CALCULATIONS Parameter Comments Input signal level (G) CE max. o/p power (E) Gain setting E-G Isolation required (Gain + 10dB) Service antenna gain (A) Service antenna feeder loss (C) Effective radiated power (ERP) E+A-C Attenuator setting CE gain-gain setting dBm dB dBm Value dBm dBm dB dB dB dB dBm dB If the input signal level in the uplink path is known and steady, use the following calculation table to determine the gain setting. If the CE features Automatic Gain Control the attenuator should be set to zero and if not, then the attenuation setting for both uplink and downlink should be similar. UPLINK CALCULATIONS Parameter Comments Input signal level CE max. o/p power (E) Gain setting Required isolation Donor antenna gain (B) Donor antenna feeder loss (D) Effective radiated power (ERP) E+B-D Attenuator setting (CE gain-gain setting) Value dBm dBm dB dB dB dB dBm dB PBL UHF1/1A 1 & 2 Air Interface Maintenance Handbook H/book Number:-60-055900HBKM Issue No:-2 Date:-20/10/2003 Page:-85 of 85
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.3 Linearized : No Encryption : Standard V1.2 (40-bit) User Access : Print, Fill forms, Extract, Assemble, Print high-res Modify Date : 2003:10:20 21:42:43+02:00 Create Date : 2003:10:20 21:41:25-01:00 Page Count : 85 Creation Date : 2003:10:20 22:41:25Z Mod Date : 2003:10:20 22:41:25Z Producer : Acrobat Distiller 5.0 (Windows) Author : chrish Metadata Date : 2003:10:20 22:41:25Z Creator : chrish Title : RECEIVER MULTICOUPLER Page Mode : UseNoneEXIF Metadata provided by EXIF.tools