Panasonic of North America 96NKX-HNC600 DECT 6.0 Outdoor Camera User Manual 5 258223 KX HNC600 UPCS FCC15D
Panasonic Corporation of North America DECT 6.0 Outdoor Camera 5 258223 KX HNC600 UPCS FCC15D
Contents
- 1. Test Report
- 2. User Manual
Test Report
Report No. 258223-5 Test Report Product UPCS Transceiver in Outdoor Camera Name and address of the applicant Panasonic Corporation of North America Name and address of the manufacturer Panasonic System Networks Co., Ltd. 1-62, 4-chome, Minoshima, Hakata-ku Fukuoka 812-8531, Japan Model KX-HNC600 Rating 120 V AC (Mains) Trademark Panasonic Serial number Additional information DECT 6.0 Tested according to FCC Part 15, subpart D Isochronous UPCS Device, 1920 – 1930 MHz Industry Canada RSS 213, Issue 2 2 GHz License-exempt Personal Communications Service Devices (LE-PCS) Order number 258223 Tested in period 2014.05.07 to 2014.05.14 Issue date 2014.05.26 Name and address of the testing laboratory FCC No: 994405 IC OATS: 2040D-1 Instituttveien 6 Kjeller, Norway TEL: (+47) 22 96 03 30 FAX: (+47) 22 96 05 50 Prepared by [Frode Sveinsen] Approved by [G.Suhanthakumar] This report shall not be reproduced except in full without the written approval of Nemko. Opinions and interpretations expressed within this report are not part of the current accreditation. This report was originally distributed electronically with digital signatures. For more information contact Nemko. Template version: B Nemko Norway Nemko AS, Instituttveien 6, P.O. Box 96 Kjeller, 2007 Kjeller, Norway TEL +47 22 96 03 30 FAX +47 22 96 05 50 EMAIL info@nemko.com ENTERPRISE NUMBER NO974404532 nemko.com/no TEST REPORT FCC part 15D Report no.: 258223-5 FCC ID: ACJ96NKX-HNC600 CONTENTS 1.1 1.2 1.3 1.4 1.5 1.6 1.7 INFORMATION ................................................................................................................................. 3 Tested Item........................................................................................................................................ 3 Description of Tested Device............................................................................................................. 3 Exposure Evaluation .......................................................................................................................... 3 Test Environment .............................................................................................................................. 4 Test Engineer(s) ................................................................................................................................ 4 Test Equipment ................................................................................................................................. 4 Other Comments ............................................................................................................................... 4 2.1 2.2 TEST REPORT SUMMARY .............................................................................................................. 5 General .............................................................................................................................................. 5 Test Summary ................................................................................................................................... 6 3.1 3.2 3.3 3.4 3.5 3.6 3.7 3.8 3.9 3.10 3.11 3.12 3.13 3.14 3.15 3.16 3.17 3.18 3.19 3.20 3.21 3.22 TEST RESULTS ................................................................................................................................ 7 Power Line Conducted Emissions ..................................................................................................... 7 Coordination with fixed microwave .................................................................................................. 10 Digital Modulation Techniques ........................................................................................................ 10 Labeling Requirements ................................................................................................................... 10 Antenna Requirement...................................................................................................................... 11 Channel Frequencies ...................................................................................................................... 11 Automatic Discontinuation of Transmission .................................................................................... 12 Peak Power Output ......................................................................................................................... 13 Emission Bandwidth B ..................................................................................................................... 16 Power Spectral Density ................................................................................................................... 19 In-Band Unwanted Emissions, Conducted ...................................................................................... 22 Out-of-band Emissions, Conducted................................................................................................. 24 Carrier Frequency Stability .............................................................................................................. 30 Frame Repetition Stability ............................................................................................................... 31 Frame Period and Jitter ................................................................................................................... 31 Monitoring Threshold, Least Interfered Channel ............................................................................. 33 Threshold Monitoring Bandwidth ..................................................................................................... 35 Reaction Time and Monitoring Interval ............................................................................................ 36 Time and Spectrum Window Access Procedure ............................................................................. 38 Acknowledgements and Transmission Duration ............................................................................. 39 Dual Access Criteria Check ............................................................................................................. 41 Alternative Monitoring Interval ......................................................................................................... 45 4.1 4.2 4.3 4.4 4.5 TEST SETUPS ................................................................................................................................ 46 Frequency Measurements ............................................................................................................... 46 Timing Measurements ..................................................................................................................... 46 Conducted Emission Test................................................................................................................ 46 Power Line Conducted Emissions Test ........................................................................................... 46 Monitoring Tests .............................................................................................................................. 47 TEST EQUIPMENT USED .............................................................................................................. 48 Nemko Norway, Instituttveien 6, Kjeller, Norway Page 2 (48) TEST REPORT FCC part 15D Report no.: 258223-5 FCC ID: ACJ96NKX-HNC600 1.1 INFORMATION Tested Item Name : Model name : FCC ID : Industry Canada ID : Serial number : Hardware identity and/or version: Software identity and/or version : Tested to IC Radio Standard (RSS) : Test Site IC Reg. Number : Frequency Range : Number of Channels : Type of Modulation : Conducted Output Power : Antenna Connector : Number of Antennas : Antenna Diversity Supported : Power Supply : 1.2 Panasonic KX-HNC600 ACJ96NKX-HNC600 216A-KXHNC600 PNLB2371xx SW401 RSS-213 Issue 2, RSS-GEN Issue 3 IC 2040D-1 1921.536 – 1928.448 MHz 5 RF Channels, 5x12 = 60 TDMA Duplex Channels Digital (Gaussian Frequency Shift Keying) 62 mW (Peak) None No AC Adaptor Model: PNLV236 Description of Tested Device The EUT is an Indoor Camera with DECT Transmitter and is an initiating device as described in ANSI C63.17 and is designed to operate together with a DECT fixed part (i.e. a base station), which is the responding device. 1.3 Exposure Evaluation The EUT is a fixed device and the user manual contains a statement that it should be installed at least 20cm away from any persons. Nemko Norway, Instituttveien 6, Kjeller, Norway Page 3 (48) TEST REPORT FCC part 15D Report no.: 258223-5 FCC ID: ACJ96NKX-HNC600 1.4 Test Environment Temperature: 20.7 – 21.8 °C Relative humidity: 36 - 43 % Normal test voltage: 120 V AC (with AC Adaptor PNLV236) The values are the limit registered during the test period. 1.5 Test Engineer(s) Frode Sveinsen Thanh Tran 1.6 Test Equipment See list of test equipment in clause 6. 1.7 Other Comments The Monitoring and Time and Spectrum Window Access tests were performed with Test Set-Up 6 (Ref. clause 5). A clock signal from the companion device was used to synchronize the Pulse Pattern Generator and the Spectrum Analyzer to the start of the DECT time window. The EUT was limited by administrative commands to operate on only two frequency carriers. For the tests where the EUT was required to operate on only one frequency carrier, one carrier was blocked by applying a CW interfering signal from RF Generator 3. The Pulse Pattern Generator was used to apply time synchronized interference to time windows where this was required. This EUT supports Least Interfered Channel procedure (LIC), the Monitoring and Time and Spectrum Window Access tests were conducted as specified for EUTs that support LIC procedure. All tests except Power-Line Conducted Emissions were performed in conducted mode with a temporary antenna connector. Nemko Norway, Instituttveien 6, Kjeller, Norway Page 4 (48) TEST REPORT FCC part 15D Report no.: 258223-5 FCC ID: ACJ96NKX-HNC600 TEST REPORT SUMMARY 2.1 General All measurements are traceable to national standards. The tests were conducted on a sample of the equipment for the purpose of demonstrating compliance with FCC CFR47 Part 15D for Isochronous UPCS Devices and Industry Canada RSS-213 Issue 2 / RSS-GEN Issue 3. All tests were conducted is accordance with ANSI C63.4-2009 and ANSI C63.17-2006. Antenna Gain tests were made in a 3m fully-anechoic chamber. A description of the test facility is on file with the FCC and Industry Canada. New Submission Production Unit Class II Permissive Change Pre-production Unit PUB Equipment Code Family Listing THIS TEST REPORT APPLIES ONLY TO THE ITEM(S) AND CONFIGURATIONS TESTED. Deviations from, additions to, or exclusions from the test specifications are described in “Summary of Test Data”. Nemko Group authorizes the above named company to reproduce this report provided it is reproduced in its entirety and for use by the company’s employees only. Any reproduction of parts of this report requires approval in writing from Nemko Group. Any use which a third party makes of this report, or any reliance on or decisions to be made based on it, are the responsibility of such third parties. Nemko Group accepts no responsibility for damages suffered by any third party as a result of decisions made or actions based on this report. Nemko Norway, Instituttveien 6, Kjeller, Norway Page 5 (48) TEST REPORT FCC part 15D Report no.: 258223-5 FCC ID: ACJ96NKX-HNC600 2.2 Test Summary Name of test FCC CFR 47 Paragraph # IC RSS-213 Paragraph # Verdict Power Line Conducted Emission 15.107(a) 15.207(a) 6.3 RSS-GEN 7.2.2 Complies Coordination with fixed microwave 15.307(b) N/A Complies Digital Modulation Techniques 15.319(b) 6.1 Complies Labeling requirements 15.19(a)(3) RSS-GEN 5.2 Complies Antenna Requirement 15.317, 15.203 RSS-GEN 7.1.2 Complies Channel Frequencies 15.303 Complies Automatic discontinuation of transmission 15.319(f) 4.3.4(a) Complies Emission Bandwidth 15.323(a) 6.4 Complies In-band emissions 15.323(d) 6.7.2 Complies Out-of-band emissions 15.323(d) 6.7.1 Complies Output Power and Antenna Gain 15.319(c)(e), 15.31(e) 6.5 and 4.1(e) Complies Power Spectral Density 15.319(d) 4.3.2.1 Complies Carrier frequency stability 15.323(f) 6.2 Complies Frame repetition stability 15.323(e) 4.3.4(c) Complies Frame period and jitter 15.323(e) 4.3.4(c) Complies Monitoring threshold, Least interfered channel 15.323(c)(2);(5); (9) 4.3.4(b) Complies Monitoring of intended transmit window and maximum reaction time 15.323(c)(1) 4.3.4(b) Complies Threshold monitoring bandwidth 15.323(c)(7) 4.3.4(b) Complies Reaction time and monitoring interval 15.323(c)(1);(5); (7) 4.3.4(b) Complies Access criteria test interval 15.323(c)(4);(6) 4.3.4(b) N/A Access Criteria functional test 15.323(c)(4);(6) 4.3.4(b) N/A Acknowledgements 15.323(c)(4) 4.3.4(b) Complies Transmission duration 15.323(c)(3) 4.3.4(b) Complies Dual access criteria 15.323(c)(10) 4.3.4(b) Complies Alterative monitoring interval 15.323(c)(10);(11) 4.3.4(b) N/A Spurious Emissions (Radiated) 15.319(g) 15.109(a) 15.209(a) 4.3.3 RSS-GEN 7.2.3 N/A Only applies for equipment that transmits unacknowledged control and signaling information The client declares that the tested equipment does not implement this provision Not required if the Conducted Out-of-Band Emissions test is Passed Nemko Norway, Instituttveien 6, Kjeller, Norway Page 6 (48) TEST REPORT FCC part 15D Report no.: 258223-5 FCC ID: ACJ96NKX-HNC600 3.1 TEST RESULTS Power Line Conducted Emissions Para. No.: 15.207 (a) Test Performed By: Thanh Tran Date of Test: 13-May-2014 Measurement procedure: ANSI C63.4-2009 using 50 µH/50 ohms LISN. Test Results: Complies Measurement Data: See attached graph, (Peak detector). Highest measured value (L1 and N): (Plots show maximum of Phase L1 and N) Nemko Norway, Instituttveien 6, Kjeller, Norway Page 7 (48) TEST REPORT FCC part 15D Report no.: 258223-5 FCC ID: ACJ96NKX-HNC600 Standby Mode with PNLV236 Adaptor, 120V 60Hz: Frequency Level Af Limit Margin Det Position Verdict [MHz] [dBuV] [dB] [dBuV] [dB] 0.395000 39.00 10.20 58.00 19.00 QP L1 Pass 0.370000 29.00 10.20 48.50 19.50 AV L1 Pass 0.395000 36.50 10.20 48.00 11.50 AV L1 Pass 0.445000 20.20 10.20 47.00 26.80 AV L1 Pass 0.480000 11.20 10.20 46.30 35.10 AV L1 Pass 0.740000 22.10 10.20 46.00 23.90 AV L1 Pass 0.760000 19.40 10.20 46.00 26.60 AV L1 Pass 0.785000 17.40 10.20 46.00 28.60 AV Pass 0.815000 19.90 10.20 46.00 26.10 AV Pass 0.840000 18.90 10.20 46.00 27.10 AV Pass 0.945000 15.10 10.20 46.00 30.90 AV Pass 1.155000 17.10 10.20 46.00 28.90 AV Pass 1.180000 15.00 10.20 46.00 31.00 AV Pass 1.240000 11.70 10.20 46.00 34.30 AV L1 Pass 1.455000 13.90 10.20 46.00 32.10 AV L1 Pass 22.325000 14.30 11.30 50.00 35.70 AV Pass Det Position Verdict [Pass/Fail] Transmit Mode with PNLV236 Adaptor, 120V 60Hz: Frequency Level Af Limit Margin [MHz] [dBuV] [dB] [dBuV] [dB] 0.395000 39.20 10.20 58.00 18.80 QP L1 Pass 0.750000 30.30 10.20 56.00 25.70 QP Pass 0.170000 16.00 10.10 55.00 39.00 AV L1 Pass 0.370000 28.40 10.20 48.50 20.10 AV L1 Pass 0.395000 36.50 10.20 48.00 11.50 AV L1 Pass 0.570000 17.30 10.20 46.00 28.70 AV Pass 0.750000 9.00 10.20 46.00 37.00 AV Pass 0.785000 18.00 10.20 46.00 28.00 AV Pass [Pass/Fail] 0.830000 6.90 10.20 46.00 39.10 AV Pass 0.865000 17.00 10.20 46.00 29.00 AV Pass 0.950000 12.00 10.20 46.00 34.00 AV Pass 1.695000 10.70 10.20 46.00 35.30 AV L1 Pass 1.925000 12.20 10.20 46.00 33.80 AV L1 Pass 8.670000 15.10 10.60 50.00 34.90 AV L1 Pass 12.200000 13.00 10.70 50.00 37.00 AV L1 Pass 18.000000 11.30 11.00 50.00 38.70 AV L1 Pass 22.205000 15.20 11.30 50.00 34.80 AV Pass Nemko Norway, Instituttveien 6, Kjeller, Norway Page 8 (48) TEST REPORT FCC part 15D Report no.: 258223-5 FCC ID: ACJ96NKX-HNC600 Level [dBµV] 80 70 60 50 40 30 + ++ 20 10 150k 300k 500k 1M Frequency [Hz] 2M 3M 5M 7M 10M 30M MES 258223N_Qp MES 258223N_Av MES 258223N LIM EN 55022 V QP LIM EN 55022 V AV Standby Mode with PNLV236 Adaptor, 120V 60Hz Level [dBµV] 80 70 60 50 40 30 20 10 + + 150k 300k 500k + + 1M Frequency [Hz] 2M 3M 5M 7M 10M 30M MES 258223N_Qp MES 258223N_Av MES 258223N LIM EN 55022 V QP LIM EN 55022 V AV Transmit Mode with PNLV236 Adaptor, 120V 60Hz Nemko Norway, Instituttveien 6, Kjeller, Norway Page 9 (48) TEST REPORT FCC part 15D Report no.: 258223-5 FCC ID: ACJ96NKX-HNC600 3.2 Coordination with fixed microwave The affidavit from UTAM, Inc. is included in the documentation supplied by the applicant: Yes No Requirement, FCC 15.307 (b): Each application for certification of equipment operating under the provisions of this Subpart must be accompanied by an affidavit from UTAM, Inc. certifying that the applicant is a participating member of UTAM, Inc. In the event a grantee fails to fulfill the obligations attendant to participation in UTAM, Inc., the Commission may invoke administrative sanctions as necessary to preclude continued marketing and installation of devices covered by the grant of certification, including but not limited to revoking certification. 3.3 Digital Modulation Techniques The EUT uses Multi Carrier / Time Division Multiple Access / Time Division Duplex and Digital GFSK modulation. For further details see the operational description provided by the applicant. Requirement, FCC 15.319(b): All transmissions must use only digital modulation techniques. 3.4 Labeling Requirements See separate documents showing the label design and the placement of the label on the EUT. Requirements FCC 15.19 The FCC Identifier shall be displayed on the label, and the device(s) shall bear the following statement in a conspicuous location on the device or in the user manual if the device is too small: This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. The label itself shall be of a permanent type, not a paper label, and shall last the lifetime of the equipment. Nemko Norway, Instituttveien 6, Kjeller, Norway Page 10 (48) TEST REPORT FCC part 15D Report no.: 258223-5 FCC ID: ACJ96NKX-HNC600 3.5 Antenna Requirement Does the EUT have detachable antenna(s)? Yes No If detachable, is the antenna connector(s) non-standard? Yes No The tested equipment has only integral antennas. The conducted tests were performed on a sample with a temporary antenna connector. Requirement: FCC 15.203, 15.204, 15.317. 3.6 Channel Frequencies UPCS CHANNEL FREQUENCY (MHz) Upper Band Edge 1930.000 0 (Highest) 1928.448 1926.720 1924.992 1923.264 4 (Lowest) 1921.536 Lower Band Edge 1920.000 Requirement: FCC 15.303 Within 1920 -1930 MHz band for isochronous devices. Nemko Norway, Instituttveien 6, Kjeller, Norway Page 11 (48) TEST REPORT FCC part 15D Report no.: 258223-5 FCC ID: ACJ96NKX-HNC600 3.7 Automatic Discontinuation of Transmission Does the EUT transmit Control and Signaling Information? YES TYPE OF EUT : RESPONDING DEVICE INITIATING DEVICE NO The following tests simulate the reaction of the EUT in case of either absence of information to transmit or operational failure after a connection with the companion device is established. Number N/A Test EUT Reaction Verdict Pass Power removed from EUT Switch Off EUT N/A Pass Hook-On by EUT N/A Pass Power Removed from Companion Device Pass Switch Off Companion Device N/A Pass Hook-On by Companion Device N/A Pass - Connection breakdown, Cease of all transmissions - Connection breakdown, EUT transmits control and signaling information - Connection breakdown, Companion Device transmits control and signaling information - Not Applicable (Neither EUT nor Companion Device have On/Off switch or can perform Hook-On) Requirements, FCC 15.319(f) The device shall automatically discontinue transmission in case of either absence of information to transmit or operational failure. These provisions are not intended to preclude transmission of control and signaling information or use of repetitive codes used by certain digital technologies to complete frame or burst intervals. Nemko Norway, Instituttveien 6, Kjeller, Norway Page 12 (48) TEST REPORT FCC part 15D Report no.: 258223-5 FCC ID: ACJ96NKX-HNC600 3.8 Peak Power Output Test Method: ANSI C63.17, clause 6.1.2. Test Results: Complies Measurement Data: Maximum Conducted Output Power Channel No. Frequency (MHz) Maximum Conducted Output Power (dBm) Maximum Antenna Gain (dBi) Maximum Radiated Output Power (dBm) 1921.536 17.6 0.0* 17.6 1924.992 18.0 0.0* 18.0 1928.448 17.8 0.0* 17.8 *Antenna gain value is declared by the manufacturer. Limit: Conducted: 100 µW x SQRT(B) where B is the measured Emission Bandwidth in Hz FCC 15.319(c)(e): 20.76 dBm (119 mW) RSS-213, Issue 2: 20.51 dBm (113 mW) The antenna gain is below 3 dBi, no reduction in transmit power is necessary. Requirements, FCC 15.319(c)(e), RSS-213, Issue 2 Peak transmit power shall not exceed 100 microwatts multiplied by the square root of the emission bandwidth in Hertz. The peak transmit power shall be reduced by the amount in decibels that the maximum directional gain of the antenna exceeds 3 dBi. Nemko Norway, Instituttveien 6, Kjeller, Norway Page 13 (48) TEST REPORT FCC part 15D Report no.: 258223-5 FCC ID: ACJ96NKX-HNC600 Conducted Peak Output Power Lower Channel Upper Channel Nemko Norway, Instituttveien 6, Kjeller, Norway Page 14 (48) TEST REPORT FCC part 15D Report no.: 258223-5 FCC ID: ACJ96NKX-HNC600 Middle Channel Nemko Norway, Instituttveien 6, Kjeller, Norway Page 15 (48) TEST REPORT FCC part 15D Report no.: 258223-5 FCC ID: ACJ96NKX-HNC600 3.9 Emission Bandwidth B Test Method: ANSI C63.17, clause 6.1.3. Test Results: Complies Measurement Data: Channel No. Frequency (MHz) 26 dB Bandwidth B (kHz) 1921.536 1420 1928.448 1410 Channel No. Frequency (MHz) 99% Bandwidth (kHz) 1924.992 1266 Channel No. Frequency (MHz) 6 dB Bandwidth (kHz) 1921.536 N/A 1928.448 N/A Channel No. Frequency (MHz) 12 dB Bandwidth (kHz) 1921.536 N/A 1928.448 N/A Requirements, FCC 15.323(a) The 26 dB Bandwidth B shall be larger than 50 kHz and less than 2.5 MHz. Requirements, RSS-213 Issue 2, clause 6.4 The 99% Bandwidth shall be larger than 50 kHz and less than 2.5 MHz. No requirements for 6 and 12 dB Bandwidth, these values are only used for testing Monitoring Bandwidth if the Simple Compliance test fails (ANSI C63.17, clause 7.4). Nemko Norway, Instituttveien 6, Kjeller, Norway Page 16 (48) TEST REPORT FCC part 15D Report no.: 258223-5 FCC ID: ACJ96NKX-HNC600 Emission Bandwidth B, Lower Channel Emission Bandwidth B, Upper Channel Nemko Norway, Instituttveien 6, Kjeller, Norway Page 17 (48) TEST REPORT FCC part 15D Report no.: 258223-5 FCC ID: ACJ96NKX-HNC600 99% Bandwidth, Middle Channel Nemko Norway, Instituttveien 6, Kjeller, Norway Page 18 (48) TEST REPORT FCC part 15D Report no.: 258223-5 FCC ID: ACJ96NKX-HNC600 3.10 Power Spectral Density Test Method: ANSI C63.17, clause 6.1.5. Test Results: Complies Measurement Data: Channel No. Frequency (MHz) Power Spectral Density (dBm) 1921.536 1.1 1928.448 1.3 Averaged over 1000 sweeps. Requirements, FCC 15.319(d) The Power Spectral Density shall be less than 3 mW (4.77 dBm) when averaged over at least 100 sweeps. Nemko Norway, Instituttveien 6, Kjeller, Norway Page 19 (48) TEST REPORT FCC part 15D Report no.: 258223-5 FCC ID: ACJ96NKX-HNC600 Power Spectral Density Lower Channel: Overview Averaged, 1000 Sweeps Nemko Norway, Instituttveien 6, Kjeller, Norway Page 20 (48) TEST REPORT FCC part 15D Report no.: 258223-5 FCC ID: ACJ96NKX-HNC600 Upper Channel: Overview Averaged, 1000 Sweeps Nemko Norway, Instituttveien 6, Kjeller, Norway Page 21 (48) TEST REPORT FCC part 15D Report no.: 258223-5 FCC ID: ACJ96NKX-HNC600 3.11 In-Band Unwanted Emissions, Conducted Test Method: ANSI C63.17, clause 6.1.6.1. Test Results: Complies Measurement Data: See plots. Requirements, FCC 15.323(d): B < f ≤ 2B : at least 30 dB below max. permitted peak power 2B < f ≤ 3B : at least 50 dB below max. permitted peak power 3B < f ≤ UPCS Band Edge : at least 60 dB below max. permitted peak power Middle Channel Nemko Norway, Instituttveien 6, Kjeller, Norway Page 22 (48) TEST REPORT FCC part 15D Report no.: 258223-5 FCC ID: ACJ96NKX-HNC600 In-Band Unwanted Emissions, Conducted Lower Channel Upper Channel Nemko Norway, Instituttveien 6, Kjeller, Norway Page 23 (48) TEST REPORT FCC part 15D Report no.: 258223-5 FCC ID: ACJ96NKX-HNC600 3.12 Out-of-band Emissions, Conducted Test Method: ANSI C63.17, clause 6.1.6.2. Test Results: Complies Measurement Data: See plots. Requirements, FCC 15.323(d): f ≤ 1.25MHz outside UPCS band : 1.25MHz ≤ f ≤ 2.5MHz outside UPCS band : f ≥ 2.5MHz outside UPCS band : ≤ -9.5dBm ≤ -29.5 dBm ≤ -39.5 dBm Lower Channel: Nemko Norway, Instituttveien 6, Kjeller, Norway Page 24 (48) TEST REPORT FCC part 15D Report no.: 258223-5 FCC ID: ACJ96NKX-HNC600 Out-of-Band Emissions, Conducted Lower Channel: Nemko Norway, Instituttveien 6, Kjeller, Norway Page 25 (48) TEST REPORT FCC part 15D Report no.: 258223-5 FCC ID: ACJ96NKX-HNC600 Out-of-Band Emissions, Conducted Upper Channel: Nemko Norway, Instituttveien 6, Kjeller, Norway Page 26 (48) TEST REPORT FCC part 15D Report no.: 258223-5 FCC ID: ACJ96NKX-HNC600 Out-of-Band Emissions, Conducted Upper Channel: Nemko Norway, Instituttveien 6, Kjeller, Norway Page 27 (48) TEST REPORT FCC part 15D Report no.: 258223-5 FCC ID: ACJ96NKX-HNC600 Out-of-Band Emissions, Conducted Upper Channel: Nemko Norway, Instituttveien 6, Kjeller, Norway Page 28 (48) TEST REPORT FCC part 15D Report no.: 258223-5 FCC ID: ACJ96NKX-HNC600 Out-of-Band Emissions, Conducted Upper Channel: Nemko Norway, Instituttveien 6, Kjeller, Norway Page 29 (48) TEST REPORT FCC part 15D Report no.: 258223-5 FCC ID: ACJ96NKX-HNC600 3.13 Carrier Frequency Stability Test Method: ANSI C63.17, clause 6.2.1. Test Results: Complies Measurement Data: The Frequency Stability is measured with a R&S CMD60 DECT Tester. The CMD60 was logged by a computer programmed to get new readings as fast as possible (about 3 readings per second) over the noted time period or number of readings. The peak-to-peak difference was recorded and the mean value and deviation in ppm was calculated. The Carrier Frequency Stability over Power Supply Voltage and over Temperature is measured with a Frequency Domain Analyzer in histogram mode. Carrier Frequency Stability over Time at Nominal Temperature Average Mean Carrier Frequency (MHz) Max. Diff. (kHz) Min. Diff. (kHz) Max. Dev. (ppm) Limit 1926.726782 7.793 5.690 0.5 ±10 ppm Deviation ppm = ((Diff.) / Mean Carrier Freq.) x 10 Deviation (ppm) is calculated from 3000 readings. Frequency Stability over Power Supply Voltage at Nominal Temperature Voltage Measured Carrier Frequency (MHz) Difference (kHz) Deviation (ppm) Vnom 1924.979167 85% of Vnom 1924.976549 -1.1 -0.6 115% of Vnom 1924.977240 -1.6 -0.8 Limit ±10 ppm Deviation ppm = ((Mean – Measured Frequency) / Mean) x 10 Frequency Stability over Temperature Temperature Measured Carrier Frequency (MHz) Difference (kHz) Deviation (ppm) T = +20 °C 1924.979167 T = -20 °C 1924.978079 -2.6 -1.4 T = +50 °C 1924.977585 -1.9 -1.0 Limit ±10 ppm Deviation ppm = ((Mean – Measured Frequency) / Mean) x 10 Nemko Norway, Instituttveien 6, Kjeller, Norway Page 30 (48) TEST REPORT FCC part 15D Report no.: 258223-5 FCC ID: ACJ96NKX-HNC600 3.14 Frame Repetition Stability Test Method: ANSI C63.17, clause 6.2.2. Test Results: Complies Measurement Data: The envelope of the RF signal from the EUT is detected with a Crystal Detector and the mean and standard deviation of the frame repetition frequency is then gated over 100 frames and measured with a Frequency Domain Analyzer. The frame repetition stability is 3 times the standard deviation. Carrier Frequency (MHz) Mean (Hz) Standard Deviation (Hz) Frame Repetition Stability (ppm) 1924.992 99.999466 0.000015 0.455 Limit: Frame Repetition Stability ±10 ppm (TDMA) Ref. FCC 15.323(e), ANSI C63.17, clause 6.2.2 3.15 Frame Period and Jitter Test Method: ANSI C63.17, clause 6.2.3. Test Results: Complies Measurement Data: Carrier Frequency (MHz) Frame Period (ms) Max Jitter (µs) 3xStandard Deviation of Jitter (µs) 1924.992 99.999 -0.037 -0.025 Max Jitter = (1/ (Frame period + Pk-Pk/2)) - (1/Frame Period), when Pk-Pk and Frame Period are in Hz 3xSt.Dev.Jitter = 3x (1/(Frame Period + St.Dev) – 1/St.Dev) x 10 Limit: Frame Period 20 or 10 ms Max Jitter 25 µs 3 times St.Dev of Jitter 12.5 µs Ref. FCC 15.323(e), ANSI C63.17, clause 6.2.3 Nemko Norway, Instituttveien 6, Kjeller, Norway Page 31 (48) TEST REPORT FCC part 15D Report no.: 258223-5 FCC ID: ACJ96NKX-HNC600 Frame Repetition Stability, Gated over 100 Frames Frame Period and Jitter Nemko Norway, Instituttveien 6, Kjeller, Norway Page 32 (48) TEST REPORT FCC part 15D Report no.: 258223-5 FCC ID: ACJ96NKX-HNC600 3.16 Monitoring Threshold, Least Interfered Channel Monitoring Threshold Limits: Lower Threshold: TL = 15 log B - 184 + 30 - PEUT (dBm) Upper Threshold: TU = 15 log B - 184 + 50 - PEUT (dBm) B is measured Emission Bandwidth in Hz PEUT is measured Transmitter Power in dBm Calculated values: FCC 15.323 RSS-213, Issue 2 Lower Threshold -79.7 dBm -80.4 dBm Upper Threshold N/A -60.4 dBm Least Interfered Channel Procedure (LIC) may only be used by systems with more than 20 duplex system access channels. Systems with less than 20 duplex system access channels are not allowed to transmit when interferer level is above Lower Threshold. Upper Threshold has been removed from FCC 15D but still exists in the current Industry Canada RSS-213. Measurement Procedure: The Upper or Lower Threshold is found by the procedure defined in ANSI C63.17 clause 7.3.1 or 7.3.2. Least Interfered Channel Procedure NOT used: Lower Threshold N/A dBm -63.0 dBm Least Interfered Channel Procedure: Upper Threshold Least Interfered Channel (LIC) Procedure Test, FCC 15.323(b), (c)(2) and (c)(5) ANSI C63.17 clause 7.3.3 ref. Observation Verdict b) f1 TL + 13 dB, f2 at TL + 6 dB Transmission always on f2 Pass c) f1 TL + 6 dB, f2 at TL + 13 dB Transmission always on f1 Pass d) f1 TL + 7 dB, f2 at TL Transmission always on f2 Pass e) f1 TL, f2 at TL + 7 dB Transmission always on f1 Pass Nemko Norway, Instituttveien 6, Kjeller, Norway Page 33 (48) TEST REPORT FCC part 15D Report no.: 258223-5 FCC ID: ACJ96NKX-HNC600 Selected Channel Confirmation, FCC 15.323(c)(1) and (5) ANSI C63.17 clause 7.3.4 Observation Verdict b) Shall not transmit on f1 EUT transmits on f2 Pass d) Shall not transmit on f2 EUT transmits on f1 Pass Limits: FCC 15.323 RSS-213, Issue 2 Lower Threshold + 6 dB margin -73.7 dBm -74.4 dBm Upper Threshold + 6 dB margin N/A -54.4 dBm DELTA MARKER 2 3.03 s Ref 0 dBm * Att 10 dB RBW 300 kHz VBW 1 MHz SWT 5 s Delta 2 [T1 ] 30.77 dB 3.030000 s Marker 1 [T1 ] -50.58 dBm 329.924000 ms -10 SGL 1 PK * CLRWR TRG -20 -30 -40 -50 -60 -70 -80 -90 -100 Center 1.923264 GHz Date: 12.MAY.2014 500 ms/ 14:33:00 7.3.4 Selected Channel Confirmation, Connection 3.0s After Interferer Removed Nemko Norway, Instituttveien 6, Kjeller, Norway Page 34 (48) TEST REPORT FCC part 15D Report no.: 258223-5 FCC ID: ACJ96NKX-HNC600 3.17 Threshold Monitoring Bandwidth This test is only required if a dedicated monitoring receiver is used. However, if the test is not carried out the manufacturer shall declare and provide proper evidence that the monitoring is made through the radio receiver used for communication. Measurement Procedure: Simple Compliance Test, ANSI C63.17, clause 7.4.1 More Detailed Test, ANSI C63.17, clause 7.4.2 The test is passed if either the Simple Compliance Test or the More Detailed test is passed. During this test the spectrum analyzer is observed visually to see if the EUT transmits or not. Test Results: Test performed Observation Verdict No transmissions Pass More Detailed Test, at -6 dB points N/A N/A More Detailed Test, at -12 dB points N/A N/A Simple Compliance test, at ±30% of B The more detailed test must be pass at both the -6 and -12 dB points if the Simple Compliance test fails. Comment: The Simple Compliance Test was performed with the level at TU + UM + 10 dB to check that the EUT did not transmit at all. The tested EUT uses the same receiver for monitoring and communication, this test is therefore not required. However the test has been performed nonetheless and the test is passed. Limits, FCC 15.323(c)(7): The monitoring system bandwidth must be equal to or greater than the emission bandwidth of the intended transmission. Nemko Norway, Instituttveien 6, Kjeller, Norway Page 35 (48) TEST REPORT FCC part 15D Report no.: 258223-5 FCC ID: ACJ96NKX-HNC600 3.18 Reaction Time and Monitoring Interval Measurement Procedure ANSI C63.17, clause 7.5 Test results: By administrative commands and out-of-operating region interference, the EUT is restricted to operate on a single carrier frequency. Time-synchronized pulsed interference was then applied on the carrier at pulsed levels TU + UM to check that the EUT does not transmit at all. The level was raised 6 dB for part d) with 35 µs pulses. The pulses are synchronized with the EUT timeslots and applied centered within all timeslots. Pulse Width, ref. to ANSI C63.17 clause 7.5 Observation Verdict c) > largest of 50 µs and 50*SQRT(1.25/B) No transmissions Pass d) > largest of 35 µs and 35*SQRT(1.25/B), and with interference level raised 6 dB No transmissions Pass Comment: Since B is larger than 1.25 MHz the test was performed with pulse lengths of 50 µs and 35 µs. Limits, FCC 15.323(c)(1), (5) and (7) The maximum reaction time must be less than 50xSQRT (1.25/emission bandwidth in MHz) microseconds for signals at the applicable threshold level but shall not be required to be less than 50 microseconds. If a signal is detected that is 6 dB or more above the applicable threshold level, the maximum reaction time shall be 35xSQRT (1.25/emission bandwidth in MHz) microseconds but shall not be required to be less than 35 microseconds. Nemko Norway, Instituttveien 6, Kjeller, Norway Page 36 (48) TEST REPORT FCC part 15D Report no.: 258223-5 FCC ID: ACJ96NKX-HNC600 Ref * Att 0 dBm 10 dB RBW 1 MHz VBW 3 MHz SWT 10 ms -10 1 PK * CLRWR TRG -20 -30 -40 -50 -60 -70 -80 -90 -100 Center 1.923264 GHz Date: 12.MAY.2014 1 ms/ 14:26:59 50 µs Pulses Ref * Att 0 dBm 10 dB RBW 1 MHz VBW 3 MHz SWT 10 ms -10 1 PK * CLRWR TRG -20 -30 -40 -50 -60 -70 -80 -90 -100 Center 1.923264 GHz Date: 12.MAY.2014 1 ms/ 14:27:36 35 µs Pulses Nemko Norway, Instituttveien 6, Kjeller, Norway Page 37 (48) TEST REPORT FCC part 15D Report no.: 258223-5 FCC ID: ACJ96NKX-HNC600 3.19 Time and Spectrum Window Access Procedure This requirement is only for EUTs which transmit unacknowledged control and signaling information. Measurement Procedure: Timing for EUTs using control and signaling channel type transmissions: ANSI C63.17, clause 8.1 Test results: Access Criteria, ref. to ANSI C63.17 clause 8.1.1 Observation Verdict b) Check that the EUT transmits on the interference free time-slot N/A N/A b) The EUT must terminate or pause in its repetitive transmission of the control and signalling channel on the open channel to repeat the access criteria not less frequently than every 30 s N/A N/A If FCC 15.323(c)(6) option, If Random Waiting Interval is NOT implemented Access Criteria, ref. to ANSI C63.17 clause 8.1.2 b) Check that the EUT changes to an interference-free slot when interference is introduced on the time slot in use Observation Verdict N/A N/A If FCC 15.323(c)(6) option, Only if Random Waiting Interval is implemented Access Criteria, ref. to ANSI C63.17 clause 8.1.3 b-d) Check that the EUT uses random waiting interval before continuing transmission on an interfered time slot Comment: Observation Verdict N/A N/A The tested EUT does not transmit unacknowledged control and signaling information. Limits: FCC 15.323(c)(4): Once access to specific combined time and spectrum windows is obtained an acknowledgement from a system participant must be received by the initiating transmitter within one second or transmission must cease. Periodic acknowledgements must be received at least every 30 seconds or transmission must cease. Channels used exclusively for control and signaling information may transmit continuously for 30 seconds without receiving an acknowledgement, at which time the access criteria must be repeated. FCC 15.323(c)(6): If the selected combined time and spectrum windows are unavailable, the device may either monitor and select different windows or seek to use the same windows after waiting an amount of time, randomly chosen from a uniform random distribution between 10 and 150 milliseconds, commencing when the channel becomes available Nemko Norway, Instituttveien 6, Kjeller, Norway Page 38 (48) TEST REPORT FCC part 15D Report no.: 258223-5 FCC ID: ACJ96NKX-HNC600 3.20 Acknowledgements and Transmission Duration Measurement Procedure: Acknowledgements: ANSI C63.17, clause 8.2.1 Transmission Duration: ANSI C63.17, clause 8.2.2 During the test Initial transmission without acknowledgements the signal from the EUT to the companion device is blocked by circulators in addition to the tunable attenuator. The test Transmission time after loss of acknowledgements is performed by cutting-off the signal from the companion device by a RF switch and measuring the time until the EUT stops transmitting. The Transmission Duration test is performed by monitoring the slot in use and measuring the time until the EUT changes to a different slot. Test Results: Acknowledgements Test ref. to ANSI C63.17 clause 8.2.1 Observation Verdict a) Initial transmission without acknowledgements 0.32 sec Pass c) Transmission time after loss of acknowledgements 10.0 sec Pass Test ref. to ANSI C63.17 clause 8.2.2 Observation Verdict b) Transmission duration on same time and frequency window 2 minutes* Pass Transmission Duration Comment: *EUT stops transmitting after 2 minutes. Limits, FCC 15.323(c)(3) and (4) Occupation of the same combined time and spectrum windows by a device or group of cooperating devices continuously over a period of time longer than 8 hours is not permitted without repeating the access criteria. Once access to specific combined time and spectrum windows is obtained an acknowledgement from a system participant must be received by the initiating transmitter within one second or transmission must cease. Periodic acknowledgements must be received at least every 30 seconds or transmission must cease. Channels used exclusively for control and signaling information may transmit continuously for 30 seconds without receiving an acknowledgement, at which time the access criteria must be repeated. Nemko Norway, Instituttveien 6, Kjeller, Norway Page 39 (48) TEST REPORT FCC part 15D Report no.: 258223-5 FCC ID: ACJ96NKX-HNC600 DELTA MARKER 2 324 ms Ref 0 dBm * Att 10 dB RBW 1 MHz VBW 3 MHz SWT 2 s Delta 2 [T1 ] -0.00 dB 324.000000 ms Marker 1 [T1 ] -18.93 dBm 1.447924 s -10 SGL 1 PK * CLRWR TRG -20 -30 -40 -50 -60 -70 -80 -90 -100 Center 1.923264 GHz Date: 12.MAY.2014 200 ms/ 14:05:34 8.2.1a) Initial Transmission Without Acknowledgements DELTA MARKER 2 9.992 s Ref 0 dBm * Att 10 dB RBW 1 MHz VBW 3 MHz SWT 12 s Delta 2 [T1 ] -0.21 dB 9.992000 s Marker 1 [T1 ] -18.07 dBm 1.179924 s -10 SGL 1 PK * CLRWR TRG -20 -30 -40 -50 -60 -70 -80 -90 -100 Center 1.923264 GHz Date: 12.MAY.2014 1.2 s/ 13:43:01 8.2.1c) Transmission Time After Loss of Acknowledgements Nemko Norway, Instituttveien 6, Kjeller, Norway Page 40 (48) TEST REPORT FCC part 15D Report no.: 258223-5 FCC ID: ACJ96NKX-HNC600 3.21 Dual Access Criteria Check Measurement Procedure: EUTs that does not implement the Upper Threshold: ANSI C63.17, clause 8.3.1 EUTs that implement the Upper Threshold: ANSI C63.17, clause 8.3.2 This test is required for equipment that uses the access criteria in FCC 15.323(c)(10). Test Results: EUTs that Implements the Upper Threshold: Test ref. to ANSI C63.17 clause 8.3.2 Observation Verdict EUT can transmit Pass c) d) Transmission on interference-free receive time/spectrum window EUT transmits on interference free receive slot Pass e) f) Transmission on interference-free transmit time/spectrum window EUT transmits on interference free transmit slot Pass No connection possible Pass b) EUT is restricted to a single carrier f1 for TDMA systems. The Test is Pass if EUT can transmit g) Transmission not possible on any time/spectrum window Comment: See plots. Limits, FCC 15.323(c)(10) An initiating device may attempt to establish a duplex connection by monitoring both its intended transmit and receive time and spectrum windows. If both the intended transmit and receive time and spectrum windows meet the access criteria, then the initiating device can initiate a transmission in the intended transmit time and spectrum window. If the power detected by the responding device can be decoded as a duplex connection signal from the initiating device, then the responding device may immediately begin transmitting on the receive time and spectrum window monitored by the initiating device. Nemko Norway, Instituttveien 6, Kjeller, Norway Page 41 (48) TEST REPORT FCC part 15D Report no.: 258223-5 FCC ID: ACJ96NKX-HNC600 RESOLUTION BANDWIDTH 300 kHz Ref 0 dBm * Att 10 dB RBW 300 kHz VBW 1 MHz SWT 10 ms -10 1 PK * CLRWR TRG -20 -30 -40 -50 -60 -70 -80 -90 -100 Center 1.923264 GHz Date: 12.MAY.2014 1 ms/ 14:09:13 8.3.2c) EUT Transmits on Interference Free RECEIVE Slot, BEFORE RESOLUTION BANDWIDTH 300 kHz Ref 0 dBm * Att 10 dB RBW 300 kHz VBW 1 MHz SWT 10 ms -10 1 PK * CLRWR TRG -20 -30 -40 -50 -60 -70 -80 -90 -100 Center 1.923264 GHz Date: 12.MAY.2014 1 ms/ 14:10:22 8.3.2c) EUT Transmits on Interference Free RECEIVE Slot, AFTER Nemko Norway, Instituttveien 6, Kjeller, Norway Page 42 (48) TEST REPORT FCC part 15D Report no.: 258223-5 FCC ID: ACJ96NKX-HNC600 RESOLUTION BANDWIDTH 300 kHz Ref 0 dBm * Att 10 dB RBW 300 kHz VBW 1 MHz SWT 10 ms -10 1 PK * CLRWR TRG -20 -30 -40 -50 -60 -70 -80 -90 -100 Center 1.923264 GHz Date: 12.MAY.2014 1 ms/ 14:12:33 8.3.2e) EUT Transmits on Interference Free TRANSMIT Slot, BEFORE RESOLUTION BANDWIDTH 300 kHz Ref 0 dBm * Att 10 dB RBW 300 kHz VBW 1 MHz SWT 10 ms -10 1 PK * CLRWR TRG -20 -30 -40 -50 -60 -70 -80 -90 -100 Center 1.923264 GHz Date: 12.MAY.2014 1 ms/ 14:13:07 8.3.2e) EUT Transmits on Interference Free TRANSMIT Slot, AFTER Nemko Norway, Instituttveien 6, Kjeller, Norway Page 43 (48) TEST REPORT FCC part 15D Report no.: 258223-5 FCC ID: ACJ96NKX-HNC600 RESOLUTION BANDWIDTH 300 kHz Ref 0 dBm * Att 10 dB RBW 300 kHz VBW 1 MHz SWT 10 ms -10 1 PK * CLRWR TRG -20 -30 -40 -50 -60 -70 -80 -90 -100 Center 1.923264 GHz Date: 12.MAY.2014 1 ms/ 14:11:57 8.3.2g) No Connection Nemko Norway, Instituttveien 6, Kjeller, Norway Page 44 (48) TEST REPORT FCC part 15D Report no.: 258223-5 FCC ID: ACJ96NKX-HNC600 3.22 Alternative Monitoring Interval Test procedure described in ANSI C63.17 clause 8.4. This test is required if the EUT implements the provisions of FCC 15.323(c)(11). Test result: Not Tested. The tested EUT does not implement this provision. See manufacturers’ declaration. Nemko Norway, Instituttveien 6, Kjeller, Norway Page 45 (48) TEST REPORT FCC part 15D Report no.: 258223-5 FCC ID: ACJ96NKX-HNC600 4.1 Test Setups Frequency Measurements Modulation Domain Analyzer EUT Test equipment included: 5, 9, 19, 22, 28 Test Set-up 1 This setup is used for measuring Carrier frequency stability at normal and extreme temperatures. 4.2 Timing Measurements Crystal Detector Modulation Domain Analyzer EUT Test equipment included: 5, 7, 9, 19, 22 Test Set-up 2 This setup is used for measuring Frame repetition stability, Frame period and Jitter. 4.3 Conducted Emission Test 10 dB EUT Spectrum Analyzer Test equipment included: 1, 2, 9, 19, 22, 26 Test Set-up 3 This setup is used for all conducted emission tests. 4.4 Power Line Conducted Emissions Test Shielded Room EUT LISN Test Receiver Test equipment: 8, 17, 19, 22, 27 Test Set-Up 5 Nemko Norway, Instituttveien 6, Kjeller, Norway Page 46 (48) TEST REPORT FCC part 15D Report no.: 258223-5 FCC ID: ACJ96NKX-HNC600 4.5 Monitoring Tests Tunable Attenuator 10 dB Generator 1 CLK100 Companion Device Combining Device EUT Generator 2 Shielded Room Generator 3 Spectrum Analyzer Pulse Pattern Generator Sync signal Test equipment: 2, 3, 4, 6, 9, 10, 11, 12, 13, 14, 15, 19, 23, 24, 25, 26, 29 Test Set-Up 6 This test setup is used for all Monitoring and Time and Spectrum Access Procedure tests. The path loss from the signal generators to the EUT is measured with a power meter before the testing is started. The CLK100 is used to synchronize the Pulse-/ Pattern generator to the start of the DECT frame, this signal always comes from the base station. If the EUT is a DECT Portable Part (i.e. a handset) the CLK100 signal will come form the Companion Device. The sync signal to the Spectrum Analyzer is the CLK100 signal that is regenerated in the Pulse-/ Pattern Generator, this is used to synchronize the Spectrum Analyzer to the DECT frame when in zero span. The Pulse-/ Pattern Generator is used for tests that require time synchronized pulses or blocking of specific time slots. Nemko Norway, Instituttveien 6, Kjeller, Norway Page 47 (48) TEST REPORT FCC part 15D Report no.: 258223-5 FCC ID: ACJ96NKX-HNC600 Test Equipment Used To facilitate inclusion on each page of the test equipment used for related tests, each item of test equipment and ancillaries are identified (numbered) by the Testhouse. No. Model number Description Manufacturer Ref. no. Cal. date Cal. Due FSW26 Spectrum Analyzer Rohde & Schwarz LR 1504 2013.08.30 2014.08.30 SME03 Signal generator Rohde & Schwarz LR 1238 2013.03.19 2015.03.19 SMIQ03B Signal generator Rohde & Schwarz LR 1516 2012.11.02 2014.11.02 SMHU52 Signal generator Rohde & Schwarz LR 1240 Cal b4 use 53310A Modulation Domain Analyzer Hewlett Packard LR 1483 2013.08.14 2015.08.14 81104A Pulse-/ Pattern Generator Agilent LR 1502 2013.03.19 2015.03.19 8470B Crystal Detector Hewlett Packard LR 1207 N/A ESHS10 Measuring Receiver Rohde & Schwarz N- 3528 2012.06.28 2014.06.28 4768-10 Attenuator Narda LR1356 Cal b4 use 10 745-69 Step Attenuator Narda LR 1442 N/A 11 WE 1506A Power Splitter Weinchel LR 244 Cal b4 use 12 WE 1506A Power Splitter Weinchel LR 245 Cal b4 use 13 H-9 Hybrid Anzac LR 86 Cal b4 use 14 H-9 Hybrid Anzac LR 257 Cal b4 use 15 S212DS RF Switch Narda LR 1244 N/A 17 ESH3-Z5 Two Line V-Network Rohde & Schwarz LR 1076 Cal b4 use 19 6812B AC Power Source Agilent LR 1515 2013.10.28 2014.10.28 22 Model 87 V Multimeter Fluke N-4670 2013.10.07 2014.10.07 23 87H35-1 Circulator Racal-MESL s.no.: 140 N/A 24 87H35-1 Circulator Racal-MESL s.no.: 141 N/A 25 87H35-1 Circulator Racal-MESL s.no.: 142 N/A 26 U2000A USB Average Power Sensor Agilent LR 1523 2013.10.23 27 ESH3-Z2 Pulse Limiter Rohde & Schwarz LR 1074 Cal b4 use 28 CMD60 DECT Tester Rohde & Schwarz LR 1335 2012.11.01 2014.11.01 29 FSP30 Spectrum Analyzer Rohde & Schwarz LR1551 2013.02.25 2015.02.25 Nemko Norway, Instituttveien 6, Kjeller, Norway 2015.10.23 Page 48 (48)
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.6 Linearized : No Encryption : Standard V4.4 (128-bit) User Access : Print, Annotate, Fill forms, Extract, Print high-res Page Count : 48 XMP Toolkit : XMP toolkit 2.9.1-13, framework 1.6 About : uuid:40a4487a-e71c-11e3-0000-0c282a19bdd9 Producer : GPL Ghostscript 9.10 Keywords : () Modify Date : 2014:05:26 12:30:15+02:00 Create Date : 2014:05:26 12:30:15+02:00 Creator Tool : PDFCreator Version 1.7.2 Document ID : uuid:40a4487a-e71c-11e3-0000-0c282a19bdd9 Format : application/pdf Title : 5_258223 KX-HNC600 UPCS FCC15D Creator : sveinsenfr Description : () Author : sveinsenfr Subject :EXIF Metadata provided by EXIF.tools