Paradox Security Systems MG6130 Wireless Console User Manual MAGELLAN EP06
Paradox Security Systems Wireless Console MAGELLAN EP06
Contents
- 1. User Manual 1
- 2. User Manual 2
- 3. User Manual 3
User Manual 2
All-In-One Wireless Security System V2.0 Programming Guide Model # MG-6130 / MG-6160 We hope this product performs to your complete satisfaction. Should you have any questions or comments, please visit www.paradox.com and send us your comments. Table of Contents Things You Should Know ..................................... 2 About This Programming Guide........................................... Conventions ......................................................................... Installer Code (Default: 0000 / 000000) ............................... Maintenance Code (Default: 1111 / 111111) ....................... Master Code (Default: 1234 / 123456)................................. Wireless Output Assignment .............................. 14 Wireless Keypad Assignment ............................. 14 Wireless Repeater Assignment........................... 14 Wireless Programmable Output (PGM) Settings14 Entering Programming Mode ............................... 2 Single Digit Data Entry Method............................................ 2 Feature Select Programming Method .................................. 3 Decimal and Hexadecimal Values ....................................... 3 Wireless Supervision Options ............................ 14 Installer Quick Keys .............................................. 3 Appendix 1: PGM Event Table ............................ 18 Zone Programming................................................ 4 Appendix 2: Specifications ................................. 20 Remote Control Button Programming................. 5 Appendix 3: Connection Diagrams..................... 21 Wireless Repeater Options.................................. 16 Report Codes ....................................................... 11 Power Connections ........................................................... Telephone Line Connections ............................................ PGM Connections ............................................................. Hardwire Zone Connections.............................................. Connecting the Radio Antenna (MG-6160 only) ............... Connecting to a UIP-256................................................... X10 Transmitter Connections (MG-6160 only).................. Connecting Magellan to WinLoad ..................................... Connecting a Paradox Memory Key (PMC-4) ................... Tabletop Mounting ............................................................ Mounting Magellan on the Wall......................................... System Settings................................................... 13 Appendix 4: Ademco Contact ID Report Codes 28 Wireless Transmitter Assignment...................... 13 Appendix 5: Automatic Report Code List .......... 30 System Timers ....................................................... 6 On-board Programmable Outputs (PGMs) .......... 6 System Options ..................................................... 7 Communicator Settings ..................................... 10 21 22 23 24 24 25 25 26 26 27 27 Things You Should Know About This Programming Guide This programming guide should be used in conjunction with the Magellan Reference & Installation Manual which can be downloaded from our website at paradox.com. Use this guide to record the settings programmed for this console. Conventions This symbol designates a warning or important information. This symbol designates a suggestion or reminder. This symbol designates a reference to another section, manual or guide. This symbol designates a feature that can also be programmed in the Installer menu which can be accessed by pressing [menu] and then entering your [INSTALLER CODE]. The icon will then be followed by the path or buttons that have to be pressed in order to access the feature once in the Installer menu. For example: J[4] J[6] = Once in the Installer menu, press the [4] key and then press the [6] key to access the desired feature. Refer to the Installer Menu Overview on the back cover for more information on accessing and using the Installer menu. Installer Code (Default: 0000 / 000000) The Installer code is used to enter programming mode (see Entering Programming Mode on page 2), which allows you to program all the features, options and commands of the Magellan console except user codes. The Installer code can be 4 or 6 digits in length (see section [090] option [1] on page 7) where each digit can be any value from 0 to 9. See section [181] on page 13 to change the default code. Maintenance Code (Default: 1111 / 111111) The Maintenance code is similar to the Installer code. It can be used to enter programming mode (see Entering Programming Mode on page 2), which allows you to program all the features, options and commands except for the Magellan console’s communication settings (sections [108] to [112], sections [180] to [182]) as well as any user codes. The Maintenance code can be 4 or 6 digits in length (see section [090] option [1] on page 7) where each digit can be any value from 0 to 9. See section [182] on page 13 to change the default code (Installer only). Master Code (Default: 1234 / 123456) With the System Master code a user can use any arming method and can program user codes. The System Master code can be 4 or 6 digits in length (see section [090] option [1] on page 7), where each digit can be any digit from 0 to 9. The System Master code cannot be changed by the Installer or Maintenance code, but it can be reset to default. See section [200] on page 13 to reset to default. Entering Programming Mode Use the built-in keypad to access Magellan’s installer programming mode. To access programming mode: 1. 2. 3. 4. 5. Press and hold the [0] key. Enter your [INSTALLER CODE] or [MAINTENANCE CODE]. Enter the 3-digit [SECTION] you wish to program. Enter the required [DATA]. Press the [*] key to clear data or to go back one step. Press the [#] key to save changes. There are two methods that can be used to enter data when in programming mode: Single Digit Data Entry and Feature Select Programming methods. Single Digit Data Entry Method After entering programming mode, some sections will require that you enter decimal values from 000 to 255. Other sections will require that you enter hexadecimal values from 0 to F. The required data will be clearly indicated in this manual. When entering the final digit in a section, Magellan will automatically save and advance to the next section. Refer to Figure 1 on page 3 to see the keys and their equivalent decimal and/or hexadecimal value. Programming Guide Feature Select Programming Method After entering certain sections, eight options will be displayed where each option from [1] to [8] represents a specific feature. Press the key corresponding to the desired option and the option number will appear in the LCD screen. This means the option is ON. Press the key again to remove the digit from the LCD screen (a * appears), thereby, turning OFF the option. Press the [*] key to set all eight options to OFF. When the options are set, press the [#] key to save and advance to the next section. Decimal and Hexadecimal Values Figure 1: Decimal and Hexadecimal Values Hexadecimal only values: [1] = A [2] = B [3] = C [4] = D [5] = E [6] = F Decimal and Hexadecimal Values: Keys [0] to [9] = 0 to 9 Installer Quick Keys To access the Installer Quick keys, press and hold the [0] key from the Main keypad, enter the [INSTALLER CODE] and then press from the Center keypad: Key [1] =Test Report: Send the “Test Report” report code programmed in section [171] (page 12) to the monitoring station. Key [2] =Cancel Communication: Cancels all communication with the WinLoad software or with the monitoring station until the next reportable event. Key [3] =Answer WinLoad Software: Will force the console to answer an incoming call from the monitoring station that is using the WinLoad software. Key [4] =Call WinLoad Software: Will dial the PC telephone number programmed in section [115] (page 10) in order to initiate communication with a computer using the WinLoad software. Key [5] =Installer Test Mode: The installer test mode will allow you to perform walk tests where the siren will squawk to indicate opened zones. Press the [5] key again to exit. Magellan Zone Programming Zone Definitions ( J[4] J[6] ) 000 = Zone Disabled (default) 008 = Delayed Fire Zone 001 = Entry Delay 1 009 = 24Hr. Burglary Zone 002 = Entry Delay 2 010 = 24Hr. Hold-up Zone 003 = Follow Zone 011 = 24Hr. Buzzer Zone 004 = Follow / Stay Zone 012 = 24Hr. Gas Zone 005 = Instant Zone 013 = 24Hr. Heat Zone 006 = Instant / Stay Zone 014 = 24Hr. Water Zone 007 = Instant Fire Zone 015 = 24Hr. Freeze Zone Zone Options [1] = Auto-zone Shutdown (default) [6] = Intellizone† [2] = Bypassable Zone (default) [7] = Delay alarm transmission [3] = Future Use [8] = Force Zone (default)‡ [4] OFF OFF ON ON [5] OFF ON OFF ON Zone Alarm Type Audible alarm (default) Pulsed alarm Silent alarm Report only † Intellizone is not for use in UL installations. ‡ Force Arming is not permitted in UL installations. Section Description Zone Definition [001] Zone 1:_____________________________ ______/______/______ 1 2 Zone Options [002] Zone 2:_____________________________ ______/______/______ 1 2 [003] Zone 3:_____________________________ ______/______/______ 1 2 [004] Zone 4:_____________________________ ______/______/______ 1 2 [005] Zone 5:_____________________________ ______/______/______ 1 2 [006] Zone 6:_____________________________ ______/______/______ 1 2 [007] Zone 7:_____________________________ ______/______/______ 1 2 [008] Zone 8:_____________________________ ______/______/______ 1 2 [009] Zone 9:_____________________________ ______/______/______ 1 2 [010] Zone 10:____________________________ ______/______/______ 1 2 [011] Zone 11:____________________________ ______/______/______ 1 2 [012] Zone 12:____________________________ ______/______/______ 1 2 [013] Zone 13:____________________________ ______/______/______ 1 2 [014] Zone 14:____________________________ ______/______/______ 1 2 [015] Zone 15:____________________________ ______/______/______ 1 2 [016] Zone 16:____________________________ ______/______/______ 1 2 [017] Zone 17:____________________________ ______/______/______ 1 2 [018] Zone 18:____________________________ ______/______/______ 1 2 [019] Zone 19:____________________________ ______/______/______ 1 2 [020] Zone 20:____________________________ ______/______/______ 1 2 [021] Zone 21:____________________________ ______/______/______ 1 2 [022] Zone 22:____________________________ ______/______/______ 1 2 [023] Zone 23:____________________________ ______/______/______ 1 2 [024] Zone 24:____________________________ ______/______/______ 1 2 [025] Zone 25:____________________________ ______/______/______ 1 2 [026] Zone 26:____________________________ ______/______/______ 1 2 [027] Zone 27:____________________________ ______/______/______ 1 2 [028] Zone 28:____________________________ ______/______/______ 1 2 [029] Zone 29:____________________________ ______/______/______ 1 2 [030] Zone 30:____________________________ ______/______/______ 1 2 [031] Zone 31:____________________________ ______/______/______ 1 2 [032] Zone 32:____________________________ ______/______/______ 1 2 Programming Guide Remote Control Button Programming Section RC# Data (Default: 4DE0) Section RC# Data (Default: 4DE0) [040] Default 1-16 ______ ______ ______ ______ [041] ______ ______ ______ ______ [049] ______ ______ ______ ______ [042] ______ ______ ______ ______ [050] 10 ______ ______ ______ ______ [043] ______ ______ ______ ______ [051] 11 ______ ______ ______ ______ [044] ______ ______ ______ ______ [052] 12 ______ ______ ______ ______ [045] ______ ______ ______ ______ [053] 13 ______ ______ ______ ______ [046] ______ ______ ______ ______ [054] 14 ______ ______ ______ ______ [047] ______ ______ ______ ______ [055] 15 ______ ______ ______ ______ [048] ______ ______ ______ ______ [056] 16 ______ ______ ______ ______ Button Options Table MG-REM1 MG-REM2 0 - Button disabled 1 - Regular arming 2 - Stay arming 3 - Instant arming 4 - Force arming 5 - N/A 6 - N/A 7 - N/A 8 - Panic 1† 9 - Panic 2† A* - Panic 3† B* - PGM Activation (Event Group #7, see Appendix 1: PGM Event Table) C* - PGM Activation (Event Group #8, see Appendix 1: PGM Event Table) D* - Turn FM radio ON/OFF (MG-6160 only) E* - FM radio memory scan (MG-6160 only) F* - Non-medical alarm * = Hex values A to F are keys [17/1] to [22/6] from Magellan’s Center Keypad. Refer to Figure 1 on page 2. † = The panic feature (section [091] options [1] to [3]) must be enabled. The button of the MG-REM1 and MG-REM2 remote controls has been permanently programmed to disarm the system. However, when the system is disarmed and the Magellan console’s radio is on (MG-6160 only), the button can be used for volume control. The button’s functionality cannot be altered. The button of the MG-REM2 remote control has been permanently programmed to request feedback from the system. The button’s functionality cannot be altered. When section [040] is accessed, the console will display the contents of section [041] and copy the saved value of that section to all remote options: [041] to [56]. Magellan System Timers Section Data (value from 000 to 255) Description Defaults [060] ____/____/____ seconds Entry delay 1 ( J[4] J[4] ) [061] ____/____/____ seconds Entry delay 2 ( J[4] J[4] ) [062] ____/____/____ seconds Exit delay ( [063] ____/____/____ minutes Bell cut-off time ( [064] ____/____/____ x 15 minutes No movement time Disabled [065] ____/____/____ seconds (minimum 10 seconds) Intellizone delay 045 secs. [066] ____/____/____ seconds Recent closing delay Disabled [067] ____/____/____ times Auto-zone shutdown 005 times [068] ____/____/____ seconds PGM1 timer Disabled [069] ____/____/____ seconds PGM2 timer Disabled [070] ____/____/____ minutes Power failure report delay 015 mins. [071] ____/____/____ days Auto-test report Disabled [072] ____/____/____ rings Number of rings 008 rings [073] ____/____/____ seconds TLM fail timer 032 secs. [074] ____/____/____ seconds Answering machine override delay 030 secs. [075] ____/____/____ seconds Delay alarm transmission J[4] J[4] ) † 045 secs. † 045 secs. 060 secs. ‡ J[4] J[4] ) 004 mins. Disabled [076] ____/____/____ seconds (maximum 130 seconds) Delay between dialing attempts [077] ____/____/____ seconds Pager/voice delay 005 secs. [078] ____/____/____ seconds Remote panic disarm lock delay 020 secs. [079] ____/____/____ repetitions (maximum 10 repetitions) Voice reporting message repetitions 003 reps. [080] ____/____/____ days Closing delinquency delay Disabled [081] ____/____/____ (000 to 007**) Entry delay audio selection ( [082] ____/____/____ (000 to 007**) Exit delay audio selection ( [083] Future use Future use Future use [084] ____/____:____/____ Hours Auto-test report time Disabled [085] ____/____:____/____ Hours Auto-arm time ( Disabled J[4] J[4] ) J[4] J[4] ) J[8] J[3] ) 020 secs. 003 002 ** 000 = No tone; 001 = Beeping; 002 = Countdown; 003 = Tonality 1; 004 = Tonality 2; 005 = Tonality 3; 006 = Tonality 4; 007 = Radio tuner (MG-6160 only) † For UL installations, the Entry delay must not exceed 45 seconds. ‡ For UL installations, the Exit delay must not exceed 60 seconds. * For UL installations, the Bell cut-off time must be a minimum of 4 minutes; for cUL installations, the Bell cut-off time must be a minimum of 5 minutes. V For UL installations, the number of dialing attempts shall not exceed 10. On-board Programmable Outputs (PGMs) Section Description Event Group # Sub-group # Default [086] PGM1 Activation Event (____/____) (____/____) No event programmed [087] PGM1 Deactivation Event (____/____) (____/____) No event programmed [088] PGM2 Activation Event (____/____) (____/____) No event programmed [089] PGM2 Deactivation Event (____/____) (____/____) No event programmed Refer to Appendix 1: PGM Event Table on page 18 for the PGM events that can be used to program Magellan’s PGM outputs. Programming Guide System Options [090] General Options Bold = Default setting Option [091] ON [1] Access code length 6 digits 4 digits [2] Audible trouble warning (except AC power failures) Disabled Enabled [3] Lock master code Disabled Enabled [4] Use user code 16 as duress code Disabled Enabled [5] Console tamper supervision Disabled Enabled [6] Need code to bypass zones Disabled Enabled [7] PGM1 normal state N.O. N.C. [8] PGM2 normal state N.O. N.C. OFF ON General Options Bold = Default setting Option [092] OFF [1] Panic 1 (Emergency) Disabled Enabled [2] Panic 2 (Auxiliary) Disabled Enabled [3] Panic 3 (Fire) Disabled Enabled [4] Panic 1: Silent or audible alarm Silent Audible [5] Panic 2: Silent or audible alarm Silent Audible [6] Panic 3: Silent or audible alarm Silent Audible [7] PGM1 used as (MG-6160 only) Direct output X10 output 7 [8] PGM2 used as (MG-6160 only) Direct output X10 output 8 OFF ON Arming/Disarming Options Bold = Default setting Option [1] Auto-arm on time ( Disabled Enabled [2] Auto-arm on no movement † Disabled Enabled [3] Auto-arm in what arming mode † Regular Stay [4] Switch to Stay arming if no entry delay is opened Disabled Enabled [5] Regular arming switches to Force arming † Disabled Enabled [6] Stay arming switches to Force arming † Disabled Enabled [7] One-touch Regular/Force arming † Disabled Enabled [8] One-touch Stay arming Disabled Enabled OFF ON J[8] J[2] ) † † Force arming and Auto-arming are not for use in UL installations. [093] Arming/Disarming Options Bold = Default setting Option [1] Future use Future use Future use [2] Future use Future use Future use [3] Bell squawk when arming/disarming with remote control * Disabled Enabled [4] No exit delay when arming with remote control Disabled Enabled [5] Report system disarming Always After alarm only [6] Exit delay termination Disabled Enabled [7] Follow zones become Entry Delay 2 zones when Delay zone is bypassed Disabled Enabled [8] FM tuner ON when system is armed ( Disabled Enabled J[8] J[1] ) (MG-6160 only) * Bell Squawk on Arm must be enabled for UL installations. Magellan [094] Zone Options Bold = Default setting Option OFF ON [1] Stay delay zones Disabled Enabled [2] Report zone restore On Bell cut-off On zone closure [3] & [4] Tamper recognition options † See table See table See table See table [3] OFF OFF ON [4] OFF ON OFF ON ON - Disabled - Trouble only - Disarmed: Trouble only - Armed: Follow zone’s alarm type (page 4) - Disarmed: Audible alarm - Armed: Follow zone’s alarm type (page 4) [5] Generate tamper trouble if detected on bypassed zone No Yes [6] & [7] Wireless transmitter supervision options ‡ See table See table See table See table No Yes [8] [6] OFF OFF ON [7] OFF ON OFF ON ON - Disabled * - Trouble only - Disarmed: Trouble only - Armed: Follow zone’s alarm type (page 4) - Disarmed: Audible alarm - Armed: Follow zone’s alarm type (page 4) Generate supervision trouble if detected on bypassed zone † For UL installations, Tamper recognition options must be enabled. ‡ For UL installations, Wireless supervision options must be enabled. * For UL installations, if the zone is programmed as a wireless fire zone, supervision must be enabled and the check-in supervision time must be set at 80 minutes (section [096] option [7] on page 8). [095] Zone Options Bold = Default setting Option OFF ON [1] Zone 31 is hardwire zone 1 * Disabled Enabled [2] Zone 32 is hardwire zone 2 * Disabled Enabled [3] EOL (End-Of-Line) resistors † No EOL Use EOL resistors [4] Stay arm siren delay Disabled Enabled [5] Future use [6] Live Display Mode for Wireless Keypad (MG32WK) Disabled Enabled [7] & [8] Future use * For UL installations, if either or both of the hardwired zones are enabled, then section [095] option [3] option must be enabled. † This feature only applies to Magellan’s onboard zone inputs. Section [095] options [1] and [2] must be ON in order to use this feature. [096] General Options Bold = Default setting Option [1] & [2] [3] & [4] Doorbell 1 tone options [1] [2] OFF OFF - Tone 1 OFF ON - Tone 2 ON OFF - Tone 3 ON ON - Tone 4 Doorbell 2 tone options [3] [4] OFF OFF - Tone 1 OFF ON - Tone 2 ON OFF - Tone 3 ON ON - Tone 4 OFF ON See table See table See table See table See table See table See table See table [5] Daylight savings time Disabled Enabled [6] AC power failure warning * Disabled Enabled [7] Check-in supervision time 24Hrs 80 minutes [8] RF Jamming supervision * Disabled Enabled OFF ON * This option must be enabled for UL installations. [097] General Options Option Bold = Default setting [1] Volume boost on entry/exit delay Disabled Enabled [2] Volume boost in speakerphone mode Disabled Enabled [3] to [8] Future use Future use Future use Programming Guide [098] Dialer Options Bold = Default setting Option [1] & [2] Telephone line monitoring options * [1] [2] OFF OFF - TLM disabled OFF ON - Generate a trouble ON OFF - Generate audible alarm if armed ON ON - Silent alarms become audible OFF ON See table See table See table See table [3] Switch to pulse on 5th attempt Disabled Enabled [4] Call back Disabled Enabled [5] Alternate dialing Disabled Enabled [6] Force dial Disabled Enabled [7] DTMF dialing Disabled Enabled [8] Pulse ratio 1:2 1:1.5 * For UL installations, the telephone line monitoring must be enabled if off-premise transmission is used. [099] Dialer Options 2 * Option Bold = Default setting OFF ON [1] Use monitoring station telephone number 2 as Regular Backup [2] to [8] Future use Future use Future use * For UL installations, only one telephone number is allowed. [100] Event Call Direction Options for: Bold = Default setting Arming / Disarming Report Codes Option OFF ON [1] Call monitoring station telephone number 1 Disabled Enabled [2] Call monitoring station telephone number 2 Disabled Enabled [3] Call Pager telephone number Disabled Enabled [4] Future use Future use Future use Alarm / Alarm Restore Report Codes [101] [5] Call monitoring station telephone number 1 Disabled Enabled [6] Call monitoring station telephone number 2 Disabled Enabled [7] Call Pager telephone number Disabled Enabled [8] Future use Future use Future use Event Call Direction Options for: Bold = Default setting Tamper / Tamper Restore Report Codes Option OFF ON [1] Call monitoring station telephone number 1 Disabled Enabled [2] Call monitoring station telephone number 2 Disabled Enabled [3] Call Pager telephone number Disabled Enabled [4] Future use Future use Future use Trouble / Trouble Restore Report Codes [102] [5] Call monitoring station telephone number 1 Disabled Enabled [6] Call monitoring station telephone number 2 Disabled Enabled [7] Call Pager telephone number Disabled Enabled [8] Future use Future use Future use Event Call Direction Options for: Bold = Default setting Special Report Codes * Option OFF ON [1] Call monitoring station telephone number 1 Disabled Enabled [2] Call monitoring station telephone number 2 Disabled Enabled [3] Call Pager telephone number Disabled Enabled [4] to [8] Future use Future use Future use * For UL installations, only one telephone number is allowed. Magellan Communicator Settings Section Data Description [105] ____/____/____ Report format for monitoring station telephone number 1 ( J[4] J[3] ) [106] ____/____/____ Report format for monitoring station telephone number 2 ( J[4] J[3] ) 001 = Ademco slow (1400Hz 10BPS) 004 = Ademco Contact ID (default) 002 = Silent Knight (1400Hz 20BPS) 005 = SIA FSK [107] ____/____/____/____ Account number ( [108] ____/____/____/____ Panel identifier (for use with WinLoad software) ( [109] ____/____/____/____ Panel password (for use with WinLoad software) ( J[4] J[3] ) 003 = SESCOA (2300Hz 20BPS) 006 = ADEMCO Express (DTMF 4+2) † J[4] J[9] ) J[4] J[9] ) [110] Reserved for future use [111] Monitoring station telephone number 1 (32 digits maximum; if less than 32, press [ok] to accept) ( J[4] J[3] ) ___/___/___/___/___/___/___/___/___/___/___/___/___/___/___/___/___/___/___/___/___/___/___/___/___/___/___/___/___/___/___/___ Monitoring station telephone number 2 (32 digits maximum; if less than 32, press [ok] to accept) ( [112] J[4] J[3] ) ___/___/___/___/___/___/___/___/___/___/___/___/___/___/___/___/___/___/___/___/___/___/___/___/___/___/___/___/___/___/___/___ Pager Telephone # (32 digits maximum; if less than 32, press [ok] to accept) ( [113] J[4] J[3] ) ___/___/___/___/___/___/___/___/___/___/___/___/___/___/___/___/___/___/___/___/___/___/___/___/___/___/___/___/___/___/___/___ Numeric message sent with Pager Reporting (32 digits maximum; if less than 32, press [ok] to accept) ( [114] J[4] J[3] ) ___/___/___/___/___/___/___/___/___/___/___/___/___/___/___/___/___/___/___/___/___/___/___/___/___/___/___/___/___/___/___/___ PC telephone number for WinLoad (32 digits maximum; if less than 32, press [ok] to accept) [115] ___/___/___/___/___/___/___/___/___/___/___/___/___/___/___/___/___/___/___/___/___/___/___/___/___/___/___/___/___/___/___/___ Service telephone number* (32 digits maximum; if less than 32, press [ok] to accept) ( [116] J[4] J[3] ) (MG-6160 only) ___/___/___/___/___/___/___/___/___/___/___/___/___/___/___/___/___/___/___/___/___/___/___/___/___/___/___/___/___/___/___/___ * Using Magellan’s speakerphone feature (MG-6160 only), the Service telephone number allows the user to directly call the installer or maintenance staff if any problems arise. † If you are using any report format other than SIA in sections [105] and [106] and you would like to transmit an “A”, press [0] on the main keypad; if you would like to enter a space (non-reportable digit), press the [1] key on the center keypad. Table 1: Special Keys for Telephone Numbers Keys to press Action or Value [*] [#] Center [ACTION] (pause) key Add a 4-second pause to the telephone number. Press the key and a “P” will be inserted into the telephone number There are five personal telephone numbers used for voice reporting. These telephone numbers are programmed through the console’s communicator menu. ( J[4] J[3] ) 10 Programming Guide Report Codes Arming Report Codes Special Arming Report Codes Disarming Report Codes Default = FF Special Disarming Report Codes Section Data Section Data Section Data Section Data [120] [121] [122] [123] ____/____ User Code 1 [124] ____/____ Auto-arming [126] ____/____ User Code 1 ____/____ User Code 2 ____/____ Disarm via PC ____/____ User Code 3 ____/____ No movement ____/____ User Code 3 ____/____ Future use ____/____ User Code 4 ____/____ Partial arming ____/____ User Code 4 ____/____ Future use ____/____ User Code 5 [125] ____/____ Quick-arming [127] ____/____ User Code 5 ____/____ User Code 6 ____/____ Arming via PC ____/____ User Code 6 ____/____ User Code 7 ____/____ Future use ____/____ User Code 7 ____/____ User Code 8 ____/____ Future use ____/____ User Code 8 ____/____ User Code 9 [128] ____/____ User Code 9 ____/____ User Code 10 ____/____ User Code 10 ____/____ User Code 11 ____/____ User Code 11 ____/____ User Code 12 ____/____ User Code 12 ____/____ User Code 13 [129] ____/____ User Code 13 ____/____ User Code 14 ____/____ User Code 14 ____/____ User Code 15 ____/____ User Code 15 ____/____ User Code 16 ____/____ User Code 16 Alarm Report Codes Alarm Restore Report Codes Section Data Section Data Section Data [132] [133] [134] Magellan ____/____ End auto-arm ____/____ Late to close Alarm Report Codes [131] [130] ____/____ User Code 2 ____/____ Zone 1 ____/____ Zone 1 [143] ____/____ Zone 17 ____/____ Zone 2 ____/____ Zone 18 ____/____ Zone 3 ____/____ Zone 19 ____/____ Zone 3 ____/____ Zone 19 ____/____ Zone 4 ____/____ Zone 20 ____/____ Zone 4 ____/____ Zone 20 ____/____ Zone 5 [144] ____/____ Zone 21 ____/____ Zone 6 ____/____ Zone 22 ____/____ Zone 6 ____/____ Zone 22 ____/____ Zone 7 ____/____ Zone 23 ____/____ Zone 7 ____/____ Zone 23 ____/____ Zone 8 ____/____ Zone 24 ____/____ Zone 8 ____/____ Zone 24 ____/____ Zone 9 [145] ____/____ Zone 25 ____/____ Zone 9 [137] ____/____ Zone 21 [139] Data ____/____ Zone 18 [136] ____/____ Zone 17 Section ____/____ Zone 2 ____/____ Zone 5 [135] Default = FF Alarm Restore Report Codes ____/____ Zone 25 [140] [141] ____/____ Zone 10 ____/____ Zone 26 ____/____ Zone 10 ____/____ Zone 26 ____/____ Zone 11 ____/____ Zone 27 ____/____ Zone 11 ____/____ Zone 27 ____/____ Zone 12 ____/____ Zone 28 ____/____ Zone 12 ____/____ Zone 28 ____/____ Zone 13 ____/____ Zone 13 [146] ____/____ Zone 29 ____/____ Zone 14 [138] ____/____ Zone 30 ____/____ Zone 29 [142] ____/____ Zone 14 ____/____ Zone 30 ____/____ Zone 15 ____/____ Zone 31 ____/____ Zone 15 ____/____ Zone 31 ____/____ Zone 16 ____/____ Zone 32 ____/____ Zone 16 ____/____ Zone 32 11 Default = FF Special Alarm Report Codes Tamper Report Codes Tamper Report Codes Tamper Restore Report Codes Section Data Section Data Section Data Section Data [147] [148] ____/____ Emer. panic [149] ____/____ Zone 1 [153] ____/____ Zone 17 ____/____ Zone 18 ____/____ Zone 2 ____/____ Fire panic ____/____ Zone 3 ____/____ Zone 19 ____/____ Zone 3 ____/____ Recent closing ____/____ Zone 4 ____/____ Zone 20 ____/____ Zone shutdown [150] ____/____ Zone 5 [154] ____/____ Zone 21 ____/____ Zone 6 ____/____ Zone 22 ____/____ Zone 6 ____/____ Zone 7 ____/____ Zone 23 ____/____ Zone 7 ____/____ Future use ____/____ Zone 8 ____/____ Zone 24 ____/____ Zone 8 ____/____ Zone 9 [155] ____/____ Zone 25 ____/____ Zone 10 ____/____ Zone 11 ____/____ Zone 27 ____/____ Zone 11 ____/____ Zone 12 ____/____ Zone 28 ____/____ Zone 12 ____/____ Zone 13 [156] ____/____ Zone 29 [160] ____/____ Zone 13 ____/____ Zone 14 ____/____ Zone 30 ____/____ Zone 14 ____/____ Zone 15 ____/____ Zone 31 ____/____ Zone 15 ____/____ Zone 16 ____/____ Zone 32 ____/____ Zone 16 Section Data Section Data Section Data [165] ____/____ Zone 9 ____/____ Zone 26 System Troubles Restore Report Codes ____/____ Zone 17 [159] ____/____ Zone 10 System Trouble Report Codes [164] ____/____ Zone 5 ____/____ Paramedical Tamper Restore Report Codes [163] ____/____ Zone 4 [158] ____/____ Duress [152] [162] ____/____ Zone 1 ____/____ Zone 2 [151] [161] [157] ____/____ Aux. panic ____/____ Future use [168] ____/____ Future use Default = FF Special Report Codes Section Data [171] ____/____ Cold start ____/____ Zone 18 ____/____ AC failure ____/____ AC failure ____/____ Test report ____/____ Zone 19 ____/____ Battery failure ____/____ Battery failure ____/____ Future use ____/____ Zone 20 ____/____ Timer loss ____/____ Timer prog. ____/____ WinLoad logout ____/____ Zone 21 [166] ____/____ Unit tamper [169] ____/____ Unit tamp. rest. [172] ____/____ Installer logon ____/____ Zone 22 ____/____ Fail to comm. ____/____ Future use ____/____ Installer logout ____/____ Zone 23 ____/____ TX low battery ____/____ TX low battery ____/____ Delinquency ____/____ Zone 24 ____/____ TX superv. loss ____/____ TX superv. rest. ____/____ Future use ____/____ Zone 25 [167] ____/____ RF jamming supervision [167] ____/____ RF jamming supervision ____/____ Zone 26 ____/____ Future use ____/____ Future use ____/____ Zone 27 ____/____ Future use ____/____ Future use ____/____ Zone 28 ____/____ Future use ____/____ Future use ____/____ Zone 29 ____/____ Zone 30 ____/____ Zone 31 ____/____ Zone 32 12 Programming Guide Wireless Module Trouble Report Codes [173] [174] ____/____ PGM Supervision Loss Default = FF Wireless Module Trouble Restore Report Codes [175] ____/____ PGM Supervision Restored ____/____ PGM Tamper ____/____ PGM Tamper Restored ____/____ Keypad Supervision Loss ____/____ Keypad Supervision Restored ____/____ Keypad Battery Trouble ____/____ Keypad Battery Trouble Restored ____/____ Keypad AC Failure [176] ____/____ Keypad AC Restored ____/____ Repeater Supervision Lost ____/____ Repeater Supervision Restored ____/____ Repeater Battery Trouble ____/____ Repeater Battery Trouble Restored ____/____ Repeater AC Failure ____/____ Repeater AC Restored System Settings Section Data Description Default [180] ____/____/____ Installer code lock (Enter 147 to lock code, 000 to unlock code) 000 [181] ____/____/____/____/____/____ Installer code ( 000000 [182] ____/____/____/____/____/____ Maintenance code ( [199] Reset all programmable sections to factory default values [200] Reset Master code to default (123456) J[4] J[8] ) J[4] J[8] ) 111111 Wireless Transmitter Assignment Wireless transmitter assignment may be done through the console’s menu ( serial number in the corresponding section: Section Serial Number [201] [202] [203] [204] [205] [206] [207] [208] [209] [210] [211] [212] [213] [214] [215] [216] [217] [218] Magellan Section Zone 1: ____/____/____/____/____/____ Zone 2: ____/____/____/____/____/____ Zone 3: ____/____/____/____/____/____ Zone 4: ____/____/____/____/____/____ [219] Zone 5: ____/____/____/____/____/____ Zone 6: ____/____/____/____/____/____ Zone 7: ____/____/____/____/____/____ Zone 8: ____/____/____/____/____/____ Zone 9: ____/____/____/____/____/____ Zone 10: ____/____/____/____/____/____ Zone 11: ____/____/____/____/____/____ Zone 12: ____/____/____/____/____/____ Zone 13: ____/____/____/____/____/____ Zone 14: ____/____/____/____/____/____ Zone 15: ____/____/____/____/____/____ Zone 16: ____/____/____/____/____/____ Zone 17: ____/____/____/____/____/____ Zone 18: ____/____/____/____/____/____ [223] [220] [221] [222] [224] [225] [226] [227] [228] [229] [230] [231] [232] [233] [234] J[4] J[6] ). Alternatively, assign the transmitter by entering its Serial Number Zone 19: ____/____/____/____/____/____ Zone 20: ____/____/____/____/____/____ Zone 21: ____/____/____/____/____/____ Zone 22: ____/____/____/____/____/____ Zone 23: ____/____/____/____/____/____ Zone 24: ____/____/____/____/____/____ Zone 25: ____/____/____/____/____/____ Zone 26: ____/____/____/____/____/____ Zone 27: ____/____/____/____/____/____ Zone 28: ____/____/____/____/____/____ Zone 29: ____/____/____/____/____/____ Zone 30: ____/____/____/____/____/____ Zone 31: ____/____/____/____/____/____ Zone 32: ____/____/____/____/____/____ Wireless Doorbell 1: ____/____/____/____/____/____ Wireless Doorbell 2: ____/____/____/____/____/____ 13 Wireless Output Assignment Wireless output assignment may be done through the console’s menu ( number in the corresponding section: Section Serial Number Section J[4] J[7] ). Alternatively, assign the PGM by entering its serial Serial Number [235] PGM1: ____/____/____/____/____/____ [237] PGM3: ____/____/____/____/____/____ [236] PGM2: ____/____/____/____/____/____ [238] PGM4: ____/____/____/____/____/____ Wireless Keypad Assignment Wireless keypad assignment may be done through the console’s menu ( number in the corresponding section: Section Serial Number Section J[4] J[8] ). Alternatively, assign the keypad by entering its serial Serial Number [243] Keypad 1: ____/____/____/____/____/____ [245] Keypad 3: ____/____/____/____/____/____ [244] Keypad 2: ____/____/____/____/____/____ [246] Keypad 4: ____/____/____/____/____/____ Wireless Repeater Assignment Wireless repeater assignment may be done through the console’s menu ( serial number in the corresponding section: Section Serial Number [247] Section Repeater 1: ____/____/____/____/____/____ [248] J[4] J[9] ). Alternatively, assign the repeater by entering its Serial Number Repeater 2: ____/____/____/____/____/____ Wireless Programmable Output (PGM) Settings Section Description Event Group # (____/____) Sub-group # (____/____) Default [260] Wireless PGM1 Activation Event No event programmed [261] Wireless PGM1 Deactivation Event (____/____) (____/____) No event programmed [262] Wireless PGM2 Activation Event (____/____) (____/____) No event programmed [263] Wireless PGM2 Deactivation Event (____/____) (____/____) No event programmed [264] Wireless PGM3 Activation Event (____/____) (____/____) No event programmed [265] Wireless PGM3 Deactivation Event (____/____) (____/____) No event programmed [266] Wireless PGM4 Activation Event (____/____) (____/____) No event programmed [267] Wireless PGM4 Deactivation Event (____/____) (____/____) No event programmed Refer to Appendix 1: PGM Event Table on page 18 for the PGM events that can be used to program Magellan’s PGM outputs. Section Data Description Default [280] ____/____/____ (000 to 008) † Wireless PGM1 timer 000 [281] ____/____/____ (000 to 008) † Wireless PGM2 timer 000 [282] ____/____/____ (000 to 008) † Wireless PGM3 timer 000 [283] ____/____/____ (000 to 008) † Wireless PGM4 timer 000 † 000 = No delay; 001 = 1s delay; 002 = 5s delay; 003 = 15s delay; 004 = 30s delay; 005 = 1min delay; 006 = 5min delay; 007 = 15min delay; 008 = 30min delay. Wireless Supervision Options [290] Wireless Transmitter Supervision Zone Options * Option 14 Bold = Default setting OFF ON [1] Zone 1 supervision Disabled Enabled [2] Zone 2 supervision Disabled Enabled [3] Zone 3 supervision Disabled Enabled [4] Zone 4 supervision Disabled Enabled [5] Zone 5 supervision Disabled Enabled [6] Zone 6 supervision Disabled Enabled [7] Zone 7 supervision Disabled Enabled [8] Zone 8 supervision Disabled Enabled Programming Guide [291] Wireless Transmitter Supervision Zone Options * Option [292] ON [1] Zone 9 supervision Disabled Enabled [2] Zone 10 supervision Disabled Enabled [3] Zone 11 supervision Disabled Enabled [4] Zone 12 supervision Disabled Enabled [5] Zone 13 supervision Disabled Enabled [6] Zone 14 supervision Disabled Enabled [7] Zone 15 supervision Disabled Enabled [8] Zone 16 supervision Disabled Enabled OFF ON Wireless Transmitter Supervision Zone Options * Option [293] Bold = Default setting OFF Bold = Default setting [1] Zone 17 supervision Disabled Enabled [2] Zone 18 supervision Disabled Enabled [3] Zone 19 supervision Disabled Enabled [4] Zone 20 supervision Disabled Enabled [5] Zone 21 supervision Disabled Enabled [6] Zone 22 supervision Disabled Enabled [7] Zone 23 supervision Disabled Enabled [8] Zone 24 supervision Disabled Enabled OFF ON Wireless Transmitter Supervision Zone Options * Option Bold = Default setting [1] Zone 25 supervision Disabled Enabled [2] Zone 26 supervision Disabled Enabled [3] Zone 27 supervision Disabled Enabled [4] Zone 28 supervision Disabled Enabled [5] Zone 29 supervision Disabled Enabled [6] Zone 30 supervision Disabled Enabled [7] Zone 31 supervision Disabled Enabled [8] Zone 32 supervision Disabled Enabled * For UL installations, all programmed wireless zones must be supervised. For any wireless Fire zones in UL installations, the supervision option must be enabled (section [094] options [6] & [7]) and the check-in supervision time must be set at 80 minutes (section [096] option [7]). [294] Wireless PGM Supervision Options Option [295] Wireless PGM1 supervision Disabled Enabled [2] Wireless PGM2 supervision Disabled Enabled [3] Wireless PGM3 supervision Disabled Enabled [4] Wireless PGM4 supervision Disabled Enabled [5] to [8] Future Use OFF ON Wireless Keypad Supervision Options Bold = Default setting [1] Wireless Keypad 1 supervision Disabled Enabled [2] Wireless Keypad 2 supervision Disabled Enabled [3] Wireless Keypad 3 supervision Disabled Enabled [4] Wireless Keypad 4 supervision Disabled Enabled [5] to [8] Future Use OFF ON Wireless Repeater Supervision Options Option Magellan ON [1] Option [296] Bold = Default setting OFF Bold = Default setting [1] Wireless Repeater 1 supervision Disabled Enabled [2] Wireless Repeater 2 supervision Disabled Enabled [3] to [8] Future Use 15 [297] Wireless PGM Console Supervision Options (Follow Alarm/Follow Bell) Option Bold = Default setting OFF ON [1] PGM1 console supervision Disabled Enabled [2] PGM2 console supervision Disabled Enabled [3] PGM3 console supervision Disabled Enabled [4] PGM4 console supervision Disabled Enabled [5] to [8] Future Use Wireless Repeater Options Wireless Repeater Options Bold = Default setting Option MG-RPT1 #1 [300] OFF [1] Repeat Wireless Zone 1 Signals [2] Repeat Wireless Zone 2 Signals [3] Repeat Wireless Zone 3 Signals [4] Repeat Wireless Zone 4 Signals [5] Repeat Wireless Zone 5 Signals [6] Repeat Wireless Zone 6 Signals [7] Repeat Wireless Zone 7 Signals [8] Repeat Wireless Zone 8 Signals Wireless Repeater Options Bold = Default setting Option [1] Repeat Wireless Zone 9 Signals [2] Repeat Wireless Zone 10 Signals [3] Repeat Wireless Zone 11 Signals [4] Repeat Wireless Zone 12 Signals [5] Repeat Wireless Zone 13 Signals [6] Repeat Wireless Zone 14 Signals [7] Repeat Wireless Zone 15 Signals [8] Repeat Wireless Zone 16 Signals Option Bold = Default setting ON MG-RPT1 #1 [302] OFF [1] Repeat Wireless Zone 17 Signals [2] Repeat Wireless Zone 18 Signals [3] Repeat Wireless Zone 19 Signals [4] Repeat Wireless Zone 20 Signals [5] Repeat Wireless Zone 21 Signals [6] Repeat Wireless Zone 22 Signals [7] Repeat Wireless Zone 23 Signals [8] Repeat Wireless Zone 24 Signals 16 MG-RPT1 #1 [301] OFF Wireless Repeater Options ON ON MG-RPT1 #2 [306] OFF ON MG-RPT1 #2 [307] OFF ON MG-RPT1 #2 [308] OFF ON Programming Guide Wireless Repeater Options Bold = Default setting Option MG-RPT1 #1 [303] OFF [1] Repeat Wireless Zone 25 Signals [2] Repeat Wireless Zone 26 Signals [3] Repeat Wireless Zone 27 Signals [4] Repeat Wireless Zone 28 Signals [5] Repeat Wireless Zone 29 Signals [6] Repeat Wireless Zone 30 Signals [7] Repeat Wireless Zone 31 Signals [8] Repeat Wireless Zone 32 Signals Wireless Repeater Options Bold = Default setting Option [1] Repeat Wireless 2-Way PGM 1 Signals [2] Repeat Wireless 2-Way PGM 2 Signals [3] Repeat Wireless 2-Way PGM 3 Signals [4] Repeat Wireless 2-Way PGM 4 Signals [5] to [8] Future Use Option Bold = Default setting ON MG-RPT1 #1 [305] OFF [1] Repeat Wireless Keypad 1 Signals [2] Repeat Wireless Keypad 2 Signals [3] Repeat Wireless Keypad 3 Signals [4] Repeat Wireless Keypad 4 Signals [5] Repeat Doorbell 1 Signals [6] Repeat Doorbell 2 Signals [7] & [8] Future Use Magellan MG-RPT1 #1 [304] OFF Wireless Repeater Options ON ON MG-RPT1 #2 [309] OFF ON MG-RPT1 #2 [310] OFF ON MG-RPT1 #2 [311] OFF ON 17 Appendix 1: PGM Event Table Event Group # 00 = Zone closed 01 = Zone opened Sub-group # 01 to 32 = Zone number 99 = Any zone number 02 = System status 00 = N/A 01 = N/A 02 = Silent alarm 03 = Buzzer alarm 04 = Steady alarm 05 = Pulsed alarm 06 = Strobe 07 = Siren stopped 08 = Squawk ON* 09 = Squawk OFF* 10 = Ground start 11 = System disarmed 12 = System armed 13 = Entry delay engaged 99 = Any system status event 03 = Bell status 00 = Bell OFF 01 = Bell ON 02 = Bell Squawk Arm 03 = Bell Squawk Disarm 04 = Future use Future use 05 = Non-reportable event 00 = Telephone line trouble 01 = Future use 02 = Arm with no entry delay 03 = Arm in Stay mode 04 = Arm in Force mode 05 = Full arm when armed in Stay mode 06 = PC fail to communicate 07 = Future use 08 = Future use * Squawk ON/OFF is similar to Bell ON/OFF except it follows the arming/disarming even if section [093] option [3] is disabled (no bell squawk when arming/disarming with remote control). These 2 events are used to activate/deactivate a light, strobe, or any other PGM with squawk activation/deactivation capabilities. 05 = Non-reportable event (cont.) 09 = Doorbell 1 battery trouble 10 = Doorbell 1 battery trouble restore 11 = Doorbell 2 battery trouble 12 = Doorbell 2 battery trouble restore 13 = Utility Key 1 pressed (keys [1] and [9] from the center keypad) 14 = Utility Key 2 pressed (keys [2] and [10] from the center keypad) 15 = Utility Key 3 pressed (keys [3] and [11] from the center keypad) 16 = Utility Key 4 pressed (keys [4] and [12] from the center keypad) 17 = Utility Key 5 pressed (keys [5] and [13] from the center keypad) 18 = Utility Key 6 pressed (keys [6] and [14] from the center keypad) 19 = Utility Key 7 pressed (keys [7] and [15] from the center keypad) 20 = Utility Key 8 pressed (keys [8] and [16] from the center keypad) 21 = User remote access granted (MG-6160 only) 22 = User remote access denied (MG-6160 only) 23 = Tamper generated alarm 24 = Supervision loss generated alarm 99 = Any non-reportable event 06 = Remote access 07 = PGM activation (Remote control button option “B”; see page 5) 01 to 16 = User number 99 = Any user number 08 = PGM activation (Remote control button option “C”; see page 5) 09 = Cold Start zone 01 to 32 = Zone number 99 = Any zone number 10 = Future use Future use 11 = Smoke Maintenance signal 01 to 32 = Zone number 99 = Any zone number 18 Programming Guide Event Group # Sub-group # 12 = Delay zone alarm transmission 01 to 32 = Zone number 99 = Any zone number 13 = Arming with user 01 to 32 = User number 99 = Any user number 14 = Special arming 00 = Auto-arming 01 = Late to close 02 = No movement arming 03 = Partial arming 04 = Quick arming 05 = Arming through WinLoad 99 = Any special arming event 15 = Disarming with user 16 = Disarm after alarm with user * 01 to 16 = User number 99 = Any user number 17 = Alarm cancelled with user ** 18 = Special disarming 00 = Auto-arm cancelled 01 = Disarm through WinLoad 02 = Disarm through WinLoad after alarm * 03 = Alarm cancelled through WinLoad ** 04 = Non-medical alarm cancelled 99 = Any special disarming event 19 = Zone bypassed 20 = Zone in alarm 21 = Fire alarm 01 to 32 = Zone number 99 = Any zone number 22 = Zone alarm restore 23 = Fire alarm restore 24 = Special alarm 00 = Panic non-medical emergency 01 = Panic medical (this medical panic alarm is not UL approved) 02 = Panic fire 03 = Recent closing 04 = Global shutdown 05 = Duress alarm (User 16) 99 = Any special alarm event 25 = Zone shutdown 26 = Zone tampered 01 to 32 = Zone number 99 = Any zone number 27 = Zone tamper restore 28 = New trouble 00 = N/A 01 = AC failure 02 = Battery failure 03 = Clock loss 04 = Console tamper 05 = Fail to communicate to monitoring station 06 = Fail to communicate to voice report 07 = Fail to communicate to pager 08 = RF jamming supervision 99 = Any new trouble event 29 = Trouble restored 00 = Telephone line restored 01 = AC failure 02 = Battery failure 03 = Clock lost 04 = Console tamper restore 05 = N/A 06 = N/A 07 = N/A 08 = RF jamming restore 99 = Any trouble restore event 30 = Low battery on zone 31 = Low battery on zone restore 32 = Zone supervision trouble 01 to 32 = Zone number 99 = Any zone number 33 = Zone supervision restored * An armed system is or was in alarm and was disarmed by a user. ** A disarmed system is or was in alarm (e.g. 24Hr. zone) and was disarmed by a user. Magellan 19 Event Group # Sub-group # 34 = Special 00 = System power up 01 = Reporting test 02 = WinLoad logon 03 = WinLoad logoff 04 = Installer in programming mode 05 = Installer exited programming mode 06 = Closing delinquency delay elapsed 99 = Any special event 35 = Non-medical alarm 01 to 16 = User number 99 = Any user number 36 = Zone triggered a utility report 37 = Signal strength weak 1 01 to 32 = Zone number 99 = Any zone number 38 = Signal strength weak 2 39 = Signal strength weak 3 40 = Signal strength weak 4 41 & 42 = Reserved Reserved 43 = PGM supervision lost 44 = PGM supervision restored 45 = PGM tampered 46 = PGM tamper restored 01 to 04 = PGM number 99 = Any PGM number 47 = Wireless keypad supervision lost 48 = Wireless keypad supervision restored 49 = Wireless keypad battery trouble 50 = Wireless keypad battery trouble restored 51 = Wireless keypad AC failure 52 = Wireless keypad AC failure restored 01 to 04 = Keypad number 99 = Any keypad number 53 = Wireless repeater supervision lost 54 = Wireless repeater supervision restored 55 = Wireless repeater battery trouble 56 = Wireless repeater battery trouble restored 57 = Wireless repeater AC failure 58 = Wireless repeater AC failure restored 01 to 02 = Repeater number 99 = Any repeater number 80 = Fire delay started 01 to 32 = Zone number 99 = Any zone number 81= Fire delay cancelled 82 = PGM cold start 01 to 04 = PGM number 99 = Any PGM number 83 = Keypad cold start 01 to 04 = Keypad number 99 = Any keypad number 84 = Repeater cold start 01 to 02 = Repeater number 99 = Any repeater number Appendix 2: Specifications Input Voltage 12Vac to 16Vac* 20VA or 12Vdc to 18Vdc 1A Max. Current Consumption 1A Backup Battery 7.2Vdc NiMH rechargeable battery pack (order # 0780100178) 2 PGMs PGM1: N.O. solid-state relay (not polarized); Internal resistance 16 9(max.): Max. handling current 100mA PGM2: One low powered open-collector; Max. handling current 50mA Standby Battery Life Minimum 24 hours Temperature Range 0°C to 50°C (32°F to 122°F) Auxiliary Output When using an AC or DC power source, the auxiliary output provides 13.8V (200mA maximum)† Approvals * It is recommended that you use a 12Vac 1A transformer to power the Magellan console. The console will generate less heat when connected to a 12Vac transformer than when connected to a 16.5Vac transformer. † To achieve this value, use a minimum of 15Vdc. 20 Programming Guide Appendix 3: Connection Diagrams Power Connections Figure 2: Connecting the AC Transformer Back view of the Magellan console. 12Vac to 16Vac 1A Do not use any switchcontrolled outlets. Insert the transformer’s wires into the AC terminals. Figure 3: Connecting the DC Power Supply Back view of the Magellan console. Insert the transformer’s wires into the AC and COMMON terminals. 12Vdc to 18Vdc 1A DC Power Supply Figure 4: Connecting the Battery Back view of the Magellan console. 1. Insert the backup battery’s plug into the connector labelled BATT. 2. Slide in the battery pack horizontally, tilt the battery pack downward and then tuck it in Magellan’s battery compartment. 3. Snap in the battery compartment cover when finished. To order a battery pack, the battery pack’s part number is: Paradox #0780100178. Magellan 21 Figure 5: Auxiliary Output 13.8Vdc, 200mA Auxiliary Output Back view of the Magellan console. Telephone Line Connections Figure 6: Telephone Line Direct Connect Telephone Line Connection Note The Magellan console must be able to seize the telephone line and place a call in an emergency situation. It must be able to do this even if other equipment (telephones, answering machines, computer modems, etc.) already has the line in use. To do so, the Magellan console must be connected to a properly installed RJ31X (or RJ38X) jack that is electrically in series with and ahead of all other equipment attached to the same telephone line. Proper installation is depicted in the diagram below. If you have any questions concerning these instructions, you should consult your telephone company or a qualified installer about installing the RJ31X (or RJ38X) jack and the Magellan console for you. Back view of the Magellan console. To connect the telephone line directly to the console: 1. Connect a RJ31X to the R-1, T1, RING and TIP terminals as shown at right. 2. Connect the telephone company wires and the home telephone to the RJ31X. Figure 7: Line Plug Connection Back view of the Magellan console. Do not connect the RJ-11 cable into this plug. To connect the telephone line directly to the console: 1. Insert one end of the 4-pin RJ-11 cable into the line plug of the Magellan console. 2. Insert the other end of the RJ-11 cable into a standard telephone wall plug. 22 Programming Guide PGM Connections Figure 8: PGM1 Connections Back view of the Magellan console. Method 2 (exceeds 100mA) Method 1 (less than 100mA) Devices such as a light, etc. External DC Power Supply Devices such as a light, etc. External relay External DC Power Supply Figure 9: PGM2 Connections Back view of the Magellan console. Method 1 (less than 50mA) Devices such as a light, etc. Method 2 (exceeds 50mA) External DC Power Supply Method 3 (less than 50mA) External relay Devices such as a light, etc. External DC Power Supply Magellan Devices such as a light, etc. 23 Hardwire Zone Connections Figure 10: Hardwire Zone Connections Connecting the Radio Antenna (MG-6160 only) Figure 11: Connecting the Radio Antenna Back view of the Magellan console. If the radio reception is not very good, connect the supplied radio antenna to the ANT terminal of the Magellan console. Move the antenna around until the spot with the best reception is found. 24 Programming Guide Connecting to a UIP-256 Figure 12: Connecting to a UIP-256 Universal In-Field Programmer Connect the 10pin cable of the UIP-256 to the 10pin connector of the Magellan console Back view of the Magellan console. Standard DB-9 cable (9-pin serial cable) UIP-256 Universal In-Field Programmer Download latest firmware version of Magellan from the Paradox website at paradox.com X10 Transmitter Connections (MG-6160 only) Figure 13: Connecting the X10 Transmitter Back view of the Magellan console. 1. Connect one end of the inverted 4-pin RJ-11 cable into the X10 plug of the console. 2. Connect the other end of the inverted 4-pin RJ-11 cable into the X10 transmitter. 3. Plug the X10 transmitter into a standard wall outlet. For information on programming the X10 features of Magellan, refer to the X10 Operation User Guide which can be found and downloaded for free from our Web site at paradox.com. Do not connect the X10 transmitter into this plug. Inverted 4-pin RJ-11 cable X10 devices (transmitters, modules, etc.) are not supplied and cannot be purchased through Paradox Security Systems Ltd. Make sure that an inverted 4-pin RJ-11 cable is used when connecting the Magellan console to the X10 transmitter. Note the pin configuration below: Inverted 4-pin RJ-11 cable Magellan Console Pin 1 Pin 2 Pin 3 Pin 4 X10 Transmitter Pin 4 Pin 3 Pin 2 Pin 1 X10 transmitter Magellan 25 Connecting Magellan to WinLoad Figure 14: Connecting Magellan to WinLoad 4- to 10-pin cable (supplied with the 306 Adapter) 306 Adapter Computer containing WinLoad software Standard DB-9 cable (9-pin serial cable) Back view of the Magellan console. 4-pin connector cable Connecting a Paradox Memory Key (PMC-4) Figure 15: Connecting a Paradox Memory Key (PMC-4) PMC-4 Back view of the Magellan console. Jumper ON: Read from and/or write to memory key Jumper OFF: Write protected (Read from the memory key only) Download Data to Destination Console To download the data of a memory key into a console: 1. Remove power from the Magellan console (AC and battery) and connect the memory key to the 5-pin connector on the left side of the back of the console as shown above. 2. Re-apply both AC and battery power to the console. 3. Press the [OK] key and Magellan will begin downloading the data from the memory key. Copy Data to Memory Key from Source Console To copy the contents of a console into the memory key. The installer code of the Magellan console used to download data to the memory key must be the same installer code programmed in the Magellan console that is to download the contents from the same memory key. If the installer codes do not match, the contents of the memory key cannot be downloaded into the receiving console. Example: The contents of the Magellan console A will be copied into memory key B. The installer code for console A is 111111. In order to download the contents of memory key B into the Magellan console C, the installer code programmed in console C must also be 111111. 1. Remove power from the Magellan console (AC and battery) and connect the memory key to the 5-pin connector on the left side of the back of the console as shown above. Re-apply both AC and battery power to the console. 2. Press the [NEXT] key and then the [OK] key. Magellan will begin copying its data into the memory key. 26 Programming Guide Tabletop Mounting Figure 16: Tabletop Mounting To mount the Magellan console on a tabletop the wall plate has to be inserted beforehand: 1. Slide the wall plate’s tabs labeled B into the Magellan console’s open slots labeled D (see Figure 17 on page 27). 2. Insert two screws (included) through the wall plate’s screw holes labeled C into holes labeled E in the Magellan console (see Figure 17 on page 27). 3. Insert the two plastic feet (included) into the appropriate holes on the back plate of the Magellan console as shown at left. 4. Attach the two rubber stops (included) to the lower edge of the wall plate as shown at left. Plastic feet (x2) Back view of the Magellan console. Wall plate The plastic feet are used to raise the Magellan console to a slight angle for easy viewing while the rubber stops prevent the console from sliding when Magellan is being used. Rubber stops (x2) Tabletop mounting may not be an approved installation method by local regulations. It is recommended that the local regulations be verified prior to installing the Magellan console using this method. Tabletop Mounting Magellan on the Wall Figure 17: Mounting Magellan onto the Wall Plate To mount the wall plate: 1. Place the wall plate on the desired spot of the wall. 2. Drill and insert the screws into the holes labeled A at left. To mount the Magellan console: 1. 2. 3. 4. Place the console back plate flush against the mounted wall plate. Slide the Magellan’s open slots labeled D (see Inset 1 below) onto the wall plate’s tabs labeled B. Gently apply downward pressure to insert the wall plate’s tabs into Magellan’s open slots. Insert two screws through the wall plate’s screw holes labeled C and into Magellan’s back plate screw holes labeled E (see Inset 1 below). This will secure the console to the wall. Inset 1: Magellan’s Backplate A (x7) Magellan 27 Appendix 4: Ademco Contact ID Report Codes CID# Reporting Code Programming Value Medical Alarms - 100 CID# Reporting Code Programming Value CID# Notification appliance chk. #4 Programming Value 151 Gas detected 26 100 Medical alarm * 01 152 Refrigeration 27 101 Pendant transmitter 02 153 Loss of heat 28 330 System peripheral 4F 102 Fail to report in 03 154 Water leakage 29 331 Polling loop open 50 155 Foil break 2A 332 Polling loop short 51 Fire Alarms - 110 327 Reporting Code 4E System Peripheral Troubles - 330 and 340 110 Fire alarm 04 156 Day trouble 2B 333 Expansion module failure 52 111 Smoke 05 157 Low bottled gas level 2C 334 Repeater failure 53 112 Combustion 06 158 High temperature 2D 335 Local printer paper out 54 113 Water flow 07 159 Low temperature 2E 336 Local printer failure 55 114 Heat 08 161 Loss of air flow 2F 337 Exp. module DC loss 56 115 Pull station 09 162 Carbon monoxide detected 30 338 Exp. module low battery 57 116 Duct 0A 163 Tank level 31 339 Exp. module reset 58 117 Flame 0B 341 Exp. module tamper 59 118 Near alarm 0C Panic Alarms - 120 Fire Supervisory - 200 and 210 200 Fire supervisory 32 342 Exp. module AC loss 5A 201 Low water pressure 33 343 Exp. module self-test fail 5B Low CO2 34 344 RF receiver jam detect 5C 120 Panic Alarm 0D 202 121 Duress 0E 203 Gate valve sensor 35 122 Silent 0F 204 Low water level 36 350 Communication 5D 123 Audible 10 205 Pump activated 37 351 Telco 1 fault 5E 124 Duress - Access grated 206 Pump failure 38 352 Telco 2 fault 5F 125 Duress - Egress granted 353 Long range radio 60 12 Burglar Alarms - 130 System Troubles - 300 and 310 Communication Troubles - 350 and 360 300 System trouble 39 354 Fail to communicate 61 130 Burglary 13 301 AC loss 3A 355 Loss of radio supervision 62 131 Perimeter 14 302 Low system battery 3B 356 Loss of central polling 63 132 Interior 15 303 RAM checksum bad 3C 357 Long range radio VSWR prob. 64 133 24-hour 16 304 ROM checksum 3D 134 Entry/Exit 17 305 System reset 3E 370 Protection loop 65 135 Day/Night 18 306 Panel program changed 3F 371 Protection loop open 66 136 Outdoor 19 307 Self-test failure 40 372 Protection loop short 67 137 Tamper 1A 308 System shutdown 41 373 Fire trouble 68 138 Near alarm 1B 309 Battery test failure 42 374 Exit error alarm 69 139 Intrusion verified 1C 310 Ground fault 43 375 Panic zone trouble 6A General Alarms - 140 Protection Loop Troubles - 370 311 Battery missing/dead 44 376 Hold-up zone trouble 6B 140 General alarm 1D 312 Power supply over current limit 45 377 Swinger trouble 6C 141 Polling loop open 1E 313 Engineer reset 378 Cross-zone trouble 6D 142 Polling loop short 1F 143 Expansion module failure 20 320 Sounder/relay 47 380 Sensor trouble 6E 144 Sensor tamper 21 321 Bell 1 48 381 Loss of supervision - RF 6F 145 Expansion module tamper 22 322 Bell 2 49 382 Loss of supervision - RPM 70 146 Silent burglary 23 323 Alarm relay 4A 383 Sensor tamper 71 147 Sensor supervision failure 24 324 Trouble relay 4B 384 RF transmitter low battery 72 325 Reversing relay 4C 385 Smoke detector Hi sensitivity 73 326 Notification appliance chk. #3 4D 386 Smoke detector Low sensitivity 74 24-hour Non-burglary - 150 and 160 150 28 24-hour non-burglary 25 46 Sounder/Relay Troubles - 320 Sensor Troubles - 380 and 390 Programming Guide CID# Reporting Code Programming Value CID# Reporting Code Programming Value CID# Reporting Code Programming Value 387 Intrusion detector Hi sensitivity 75 451 Early open/close 9A 603 Periodic RF transmission BF 388 Intrusion detector Low sensitivity 76 452 Late open/close 9B 604 Fire test C0 389 Sensor self-test failure 77 453 Failed to open 9C 605 Status report to follow C1 391 Sensor watch trouble 78 454 Failed to close 9D 606 Listen-in to follow C2 392 Drift compensation error 79 455 Auto-arm failed 9E 607 Walk test mode C3 393 Maintenance alert 7A 456 Partial arm 9F 608 Periodic test - system trouble present C4 457 Exit error (user) A0 609 Video transmitter active C5 Open/Close - 400 400 Open/Close 7B 458 User on premises A1 611 Point test OK C6 401 Open/Close by user 7C 459 Recent close A2 612 Point not tested C7 402 Group open/close 7D 613 Intrusion zone walk tested C8 403 Automatic open/close 7E 461 Wrong code entry A3 614 Fire zone walk tested C9 404 Late to open/close 5E 462 Legal code entry A4 615 Panic zone walk tested CA 405 Deferred open/close 5F 463 Re-arm after alarm A5 616 Service request CB 406 Cancel 7F 464 Auto-arm time extended A6 621 Event log reset CC 407 Remote arm/disarm 80 465 Panic alarm reset A7 622 Event log 50% full CD 408 Quick arm 81 466 Service ON/OFF premises A8 623 Event log 90% full CE 409 Keyswitch open/close 82 624 Event log overflow CF Remote Access - 410 System - 460 Sounder Relay Disabled - 520 520 Sounder/Relay disabled A9 625 Time/Date reset D0 411 Call back request made 83 521 Bell 1 disabled AA 626 Time/Date inaccurate D1 412 Success - download access 84 522 Bell 2 disabled AB 627 Program mode entry D2 413 Unsuccessful access 85 523 Alarm relay disabled AC 628 Program mode exit D3 414 System shutdown 86 524 Trouble relay disabled AD 629 32-hour event log marker D4 415 Dialer shutdown 87 525 Reversing relay disabled AE 630 Schedule change D5 416 Successful upload 88 526 Notification appliance chk. #3 disabled AF 631 Exception schedule change D6 527 Notification appliance chk. #4 disabled B0 632 Access schedule change D7 654 System inactivity D8 Access Control - 420 and 430 421 Access denied 89 422 Access report by user 8A 531 Module added B1 423 Forced access 8B 532 Module removed B2 424 Egress denied 8C 425 Egress granted 8D 551 Dialer disabled B3 426 Access door propped open 8E 552 Radio transmitter disabled B4 427 Access point door status monitor trouble 8F 428 Access point request to exit 90 570 Zone bypass B5 429 Access program mode entry 91 571 Fire bypass B6 430 Access program mode exit 92 572 24Hr. zone bypass B7 431 Access threat level change 93 573 Burglary bypass B8 432 Access relay/trigger fail 94 574 Group bypass B9 433 Access RTE shunt 95 575 Swinger bypass BA 434 Access DSM shunt 96 576 Access zone shunt BB 577 Access point bypass BC Arming - 440 and 450 Modules - 530 Communication Disables - 550 and 560 Bypasses - 570 441 Armed Stay 97 442 Keyswitch armed Stay 98 601 Manual trigger test BD 450 Exception open/close 99 602 Periodic test report BE Magellan Test/Misc. - 600 29 Appendix 5: Automatic Report Code List System Event Default Contact ID Report Code when using sections [790] to [795] Default SIA Report Code when using sections [790] to [795] Arming with Master Code (##) 3 4A1 - Close by user CL - Closing Report Arming with User Code (##) 3 4A1 - Close by user CL - Closing Report Arming with Keyswitch (##) 3 4A9 - Keyswitch Close CS - Closing Keyswitch Auto Arming 3 4A3 - Automatic Close CA - Automatic Closing Arm with PC software 3 4A7 - Remote arm/disarm CL - Closing Report Late To Close 3 4A4 - Late to Close OT - Late to Close No Movement 3 4A4 - Late to Close NA - No Activity Partial arming 1 574 - Group bypass CG - Close Area Quick arming 3 408 - Quick arm CL - Closing Report Closing Delinquency 1 654 - System Inactivity CD - System Inactivity Disarm with Master Code (##) 1 4A1 - Open by user OP - Opening Report Disarm with User Code (##) 1 4A1 - Open by user OP - Opening Report Disarm with Keyswitch (##) 1 4A9 - Keyswitch Open OS - Opening Keyswitch Disarm after alarm* with Master Code (##) 1 4A1 - Open by user OP - Opening Report Disarm after alarm* with User Code (##) 1 4A1 - Open by user OP - Opening Report Disarm after alarm* with Keyswitch (##) 1 4A1 - Keyswitch Open OS - Opening Keyswitch Cancel alarm** with Master Code (##) 1 4A6 - Open by user OR - Disarm from Alarm Cancel alarm** with User Code (##) 1 4A6 - Open by user OR - Disarm from Alarm Cancel alarm** with Keyswitch (##) 1 4A6 - Keyswitch Open OS - Opening Keyswitch Auto Arming Cancellation 1 4A5 - Deferred Open/Close CE - Closing Extend Disarm with PC software 1 4A7 - Remote arm/disarm OP - Opening Report Disarm after an alarm with PC software 1 4A7 - Remote arm/disarm OR - Disarm From Alarm Quick disarm 1 408 - Quick disarm OP - Opening Report Zone Bypassed (##) 1 57A - Zone bypass UB - Untyped Zone Bypass Zone alarm (##) 1 13A - Burglary Alarm BA - Burglary Alarm Fire alarm (##) 1 11A - Fire alarm FA - Fire Alarm Zone alarm restore (##) 3 13A - Burglary Alarm Restore BH - Burglary Alarm Restore Fire alarm restore (##) 3 11A - Fire alarm Restore FH - Fire Alarm Restore Panic 1 - Emergency 1 12A - Panic alarm PA - Panic Alarm Panic 2 - Medical 1 1AA - Medical alarm MA - Medical Alarm Panic 3 - Fire 1 115 - Pull Station FA - Fire Alarm Recent closing 3 4AA - Open/Close CR - Recent Closing Global zone shutdown 1 574 - Group bypass CG - Close Area Duress alarm 1 121 - Duress HA - Hold-up Alarm Zone shutdown (##) 1 57A - Zone bypass UB - Untyped Zone Bypass Zone tampered (##) 1 144 - Sensor tamper TA - Tamper Alarm Zone tamper restore (##) 3 144 - Sensor tamper restore TR - Tamper Restoral Keypad Lockout 1 421 - Access denied JA - User Code Tamper * An armed system is or was in alarm and was disarmed by a user. ** A disarmed system is or was in alarm (e.g. 24Hr. zone) and was disarmed by a user. 30 Programming Guide System Event Default Contact ID Report Code when using sections [790] to [795] Default SIA Report Code when using sections [790] to [795] AC Failure 1 3A1 - AC loss AT - AC Trouble Battery Failure 1 3A9 - Battery test failure YT - System Battery Trouble Auxiliary supply trouble 1 3AA - System trouble YP - Power Supply Trouble Bell output current limit 1 321 - Bell 1 YA - Bell Fault Bell absent 1 321 - Bell 1 YA - Bell Fault Clock lost 1 626 - Time/Date inaccurate JT - Time Changed Fire loop trouble 1 373 - Fire trouble FT - Fire Trouble TLM trouble restore 3 351 - Telco 1 fault restore LR - Phone Line restoral AC Failure restore 3 3A1 - AC loss restore AR - AC Restoral Battery Failure restore 3 3A9 - Battery test restore YR - System Battery Restoral Auxiliary supply trouble restore 3 3AA - System trouble restore YQ - Power Supply restored Bell output current limit restore 3 321 - Bell 1 restore YH - Bell Restored Bell absent restore 3 321 - Bell 1 restore YH - Bell Restored Clock programmed 3 625 - Time/Date Reset JT - Time Changed Fire loop trouble restore 3 373 - Fire trouble restore FJ - Fire Trouble Restore Combus fault 1 333 - Expansion module failure ET - Expansion Trouble Module tamper 1 145 - Expansion module tamper TA - Tamper Alarm Module ROM_RAM_error 1 3A4 - Rom checksum bad YF - Parameter Checksum Fail Module TLM trouble 1 352 - Telco 2 fault LT - Phone Line trouble Module fail to communicate to monitoring station. 1 354 - Fail to communicate YC - Communication Fails Printer fault 1 336 - Local printer failure VT - Printer Trouble Module AC Failure 1 3A1 - AC loss AT - AC Trouble Module battery failure 1 3A9 - Battery test failure YT - System Battery Trouble Module Auxiliary supply trouble 1 3AA - System trouble YP - Power Supply Trouble Bus fault restore 3 333 - Expansion module failure restore ER - Expansion Restoral Module tamper restore 3 145 - Expansion module tamper restore TR - Tamper Restoral Module ROM_RAM_error restore 3 3A4 - Rom checksum bad restore YG - Parameter Changed Module TLM restore 3 352 - Telco 2 fault restore LR - Phone Line Restoral Printer fault restore 3 336 - Local printer failure restore VR - Printer Restore Module AC restore 3 3A1 - AC loss restore AR - AC Restoral Module battery restore 3 3A9 - Battery test failure restore YR - System Battery Restoral Module Auxiliary supply restore 3 3AA - System trouble restore YQ - Power Supply Restored Fail to communicate with monitoring station 1 354 - Fail to communicate YC - Communication Fails Module RF low battery 1 384 - RF transmitter low battery XT - Transmitter Battery Trouble Module RF battery restore 3 384 - RF transmitter battery restore XR - Transmitter Battery Restoral Module RF supervision trouble 1 381 - Loss of supervision - RF US - Untype Zone Supervision Module RF supervision restore 3 381 - Supervision restore - RF UR - Untyped Zone Restoral Cold Start 1 3A8 - System shutdown RR - Power Up Warm Start 1 3A5 - System reset YW - Watchdog Reset Test Report engaged 1 6A2 - Periodic test report TX - Test Report PC software communication finished 1 412 - Successful - download access RS - Remote Program Success Installer on site 1 627 - Program mode Entry LB - Local Program Installer programming finished 1 628 - Program mode Exit LS - Local Program Success Magellan 31 Warranty Paradox Security Systems Ltd. (“Seller”) warrants its products to be free from defects in materials and workmanship under normal use for a period of one year. Except as specifically stated herein, all express or implied warranties whatsoever, statutory or otherwise, including without limitation, any implied warranty of merchantability and fitness for a particular purpose, are expressly excluded. Because Seller does not install or connect the products and because the products may be used in conjunction with products not manufactured by Seller, Seller cannot guarantee the performance of the security system and shall not be responsible for circumstances resulting from the product’s inability to operate. Seller obligation and liability under this warranty is expressly limited to repairing or replacing, at Seller's option, any product not meeting the specifications. Returns must include proof of purchase and be within the warranty period. In no event shall the Seller be liable to the buyer or any other person for any loss or damages whether direct or indirect or consequential or incidental, including without limitation, any damages for lost profits stolen goods, or claims by any other party, caused by defective goods or otherwise arising from the improper, incorrect or otherwise faulty installation or use of the merchandise sold. Notwithstanding the preceding paragraph, the Seller’s maximum liability will be strictly limited to the purchase price of the defective product. Your use of this product signifies your acceptance of this warranty. BEWARE: Dealers, installers and/or others selling the product are not authorized to modify this warranty or make additional warranties that are binding on the Seller. Limitations of Alarm Systems It must be understood that while your Paradox alarm system is highly advanced and secure, it does not offer any guaranteed protection against burglary, fire or other emergency (fire and emergency options are only available on certain Paradox models). This is due to a number of reasons, including by not limited to inadequate or improper installation/positioning, sensor limitations, battery performance, wireless signal interruption, inadequate maintenance or the potential for the system or telephone lines to be compromised or circumvented. As a result, Paradox does not represent that the alarm system will prevent personal injury or property damage, or in all cases provide adequate warning or protection. Your security system should therefore be considered as one of many tools available to reduce risk and/or damage of burglary, fire or other emergencies, such other tools include but are not limited to insurance coverage, fire prevention and extinguish devices, and sprinkler systems. We also strongly recommend that you regularly maintain your security systems and stay aware of new and improved Paradox products and developments. Warning for Connections to Non-Traditional Telephony (e.g. VoIP) Paradox alarm equipment was designed to work effectively around traditional telephone systems. For those customers who are using a Paradox alarm panel connected to a non-traditional telephone system, such as "Voice Over Internet Protocol" (VoIP) that converts the voice signal from your telephone to a digital signal traveling over the Internet, you should be aware that your alarm system may not function as effectively as with traditional telephone systems. For example, if your VoIP equipment has no battery back-up, during a power failure your system's ability to transmit signals to the central station may be compromised. Or, if your VoIP connection becomes disabled, your telephone line monitoring feature may also be compromised. Other concerns would include, without limitation, Internet connection failures which may be more frequent than regular telephone line outages. We therefore strongly recommend that you discuss these and other limitations involved with operating an alarm system on a VoIP or other non-traditional telephone system with your installation company. They should be able to offer or recommend measures to reduce the risks involved and give you a better understanding. TBR-21 In order to comply with TBR-21, standard force dialing must be enabled. UL AND ULC WARNINGS UL AND C-UL INSTALLATION NOTES This equipment is UL listed in accordance with standard UL1023 (Household Burglar -- Alarm Systems Units), standard UL985 (Household Fire Warning Units) and standard UL1635 (Digital Alarm Communicator System Units). This equipment has the capability of being programmed with features not verified for use in UL installations. To stay within these standards, the installer should use the following guidelines when configuring the system: • All components of the system should be UL listed for the intended application. • If the system will be used for “Fire” detection, the installer should refer to NFPA Standards #72, Chapter 2. In addition, once installation is complete, the local fire authority must be notified of the installation. • This equipment must be verified by a qualified technician once every three years. • All keypads must use an anti-tamper switch. • Maximum allowed entry delay is 45 seconds. • Maximum allowed exit delay is 60 seconds. • Minimum 4 minutes for bell cut-off time. • The following features do not comply with UL requirements: Bypass Recall and Auto Trouble Shutdown. • Do not connect the primary indicating device to a relay. The installer must use the bell output. • To comply with UL985, the auxiliary power output should not exceed 200mA. • Do not connect the zone ground terminal with UL Listed products. • The metallic enclosure must be grounded to the cold water pipe. • All outputs are Class 2 or power-limited, except for the battery terminal.The Class 2 and power-limited fire alarm circuits shall be installed using CL3, CL3R, CL3P, or substitute cable permitted by the National Electrical Code, ANSI/NFPA 70. RECOMMENDED: • • • • • EOL resistor part #2011002000 For UL Installations: Universal UB1640W 16.5VAC min 40VA All outputs are rated from 11.3Vdc to 12.7Vdc 12Vdc 4Ah rechargeable acid/lead or gel cell backup battery (YUASA model #NP7-12 recommended) for residential use. Use a 7Ah battery to comply with fire requirements. Wheelock 46T-12 siren Legal © 2004-2006 Paradox Security Systems Ltd. All rights reserved. Specifications may change without prior notice. One or more of the following US patents may apply: 6215399, 6111256, 5751803, 5721542, 5287111, 5119069, 5077549, 5920259, 5886632. Canadian and international patents may also apply. Magellan is a trademark or registered trademark of Paradox Security Systems Ltd. or its affiliates in Canada, the United States and/or other countries. 32 Programming Guide NOTES Installer Menu Overview ready to arm menu Must enter the installer, maintenance or user code to access 1-bypass zones 2-alarm clock 3-time and date 4-system 1-language setup 2-user profile† 3-communicator central report? voice report? utility report? pager report? add service tel? (MG-6160 only) add tel. # 1 add tel.#1 add tel. # 1 add tel. # 1 tel.: 4-delays & tones entry delay 1? entry delay 2? exit delay? bell cutoff del? bell squawk? 5-system test test test test test 6-zone profile add add add add KEYPAD1? KEYPAD2? KEYPAD3? KEYPAD4? DELETE KEYPAD? modify label? 9-repeater profile add REPEATER1? add REPEATER2? DELETE Repeater? modify label? yes type: type: type: type: type: 11-passwords 5-chime zone 6-alarm memory 7-history log 8-utility setup 9-version number † = Master Code only = Installer Code only select user select trouble select user select zone All panics? no select TYPE: EMERGENCY AUXILIARY FIRE DURESS modify label? zone type wireless output? delete output? modify label? modify label? follow bell? remote access? alarm activation follow bell? zone activation? follow alarm? alarm activation follow arm? pulse on alarm? zone activation? follow stay arm? on for 1 sec? follow arm? console superv? on for 5 sec? follow stay arm? custom setup? on for 15 sec? console superv? no on for 30 sec? custom setup? modify button? on for 1 min? yes aNOTHER KEYPAD? on for 5 min? press button on for 15 min? on for 30 min? no select zone? select output? save profile? installer code maintenance code panel id pc password another output? 6-backlight adj. 7-contrast adj. 8-Brightness adj. ring volume? ring tone? 10-demo mode paradox.com PRINTED IN CANADA - 12/2006 follow zone? on for 1 sec? on for 5 sec? on for 15 sec? on for 30 sec? on for 1 min? on for 5 min? on for 15 min? on for 30 min? on all zones? master? yes user XX? Yes 1-radio on arm (MG-6160 only) 2-auto arming 3-auto arm time 4-lost remote 5-x10 setup (MG-6160 only) 9-Ring Set-up (MG6160 only) disarming trouble paramedic zone acti. PANIC yes select KEYPAD? 10-signal strEngth report format record alrm mes? record alrm mes? add message? open/close cover output1? output2? output3? output4? 8-keypad profile add add add add account number TEL#4 TEL.#5 report type? zones? remotes? reporting? hardware? select zone 7-output profile add backup # TEL#2 TEL#3 add tel. # 2 on time? on zone open? remote button? on exit delay? when armed? on entry delay? on alarm? house code? MAGELLAN-EP06 toggle on/off? on for 1 sec? on for 5 sec? on for 15 sec? on for 30 sec? on for 1 min? on for 5 min? on for 15 min? on for 30 min? on all remotes? master? yes user XX? Yes another output?
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.4 Linearized : No Page Count : 36 Page Mode : UseOutlines XMP Toolkit : XMP toolkit 2.9.1-13, framework 1.6 About : uuid:006fdf67-740d-4aeb-b13a-f61bcf67d24d Producer : Acrobat Distiller 6.0 (Windows) Modify Date : 2006:12:18 11:52:12Z Create Date : 2003:04:02 13:27:54Z Creator Tool : FrameMaker 7.2 Document ID : uuid:f914194e-4e1e-4f8c-8edd-611c77893293 Format : application/pdf Title : MAGELLAN_EP06.fm Creator : jkisielew Author : jkisielewEXIF Metadata provided by EXIF.tools