Paradox Security Systems NV75MR Indoor Wireless PIR detector with Anti Mask and Pet Immunity User Manual NV75MR EI00
Paradox Security Systems Indoor Wireless PIR detector with Anti Mask and Pet Immunity NV75MR EI00
Users Manual
Table 1 1 - LED NV75MR 2 - EDGE Installation Manual V1.0 3 - PET IMM. Wireless 16 Meter Indoor Dual Mironel Optics, Anti-Mask, Pet Immunity Dual Detector 4 - MHz OFF ON DUAL SINGLE OFF ON 868 MHz 433 MHz Step 3 General Description The NV75MR is an indoor industry-leading wireless detector providing superior 16 meter detection with rock solid stability thanks to the revolutionary dual Mironel Mirror/Fresnel PIR optics. Combined with Paradox true Pet Immunity and best-in-the industry active Anti-Mask technology (EN Grade 3). The NV75MR provides an unmatched high security solution for any indoor installation. Please Read Wall Mount Installing the NV75MR (Step 1) Wall Mount x6 Installation Height: Pet Immune ON - 2.0m/6.6ft to 2.4m/7.8ft Pet Immune OFF - 2.0m/6.6ft to 2.8m/9ft (lever down)* *For installations higher than 2.6m, when needed, tilt the detector down a few degrees for best detection results; use of a bracket is recommended. Bracket Adjustment Screw Opening Tamper Screw Wall/Corner Power Up (30 sec.): Powering up the detector takes about 30 seconds, indicated with green/red flashing; indicates PIR stabilizing. Bracket Mount Anti-Mask Calibration: Once detector is stabilized, as mentioned above, open and close the tamper to initiate. Anti-Mask calibration may take up to 60 seconds. Keep away from the detector, at least 2 meters / 6 feet during calibration, indicated by flashing green/red LED. Once completed, the detector is ready. Note: Do not block the detector’s field of view. Corner Mount x4 Note: Use of a bracket reduces the detector’s security grade to 1. Creep Zone/Pet Selection Step 1 Step 2 Battery Tab OFF ON 1 2 ON 3 4 DIP Switch (Table 1) 11m Cover Tamper paradox.com 9m 13m 7m 16m PIR SENSITIVITY UP - Pet DOWN - Creep Remove detector assembly as described in Step 1. When selector is UP, Pet Mode; when DOWN, Creep Zone is active and there is no Pet Immunity. Above 2.4m Pet Immune should be OFF (lever down Pet OFF, see installation height note*. NV75MR-EI00/c 12/2016 LED Display Technical Specifications Feature LED Status Indicator Tamper open Specification Green: ON for 0.3 seconds every 30 seconds Description IR Movement Detection 2 detectors, 2 dual element sensors, 2 Mironel Optics PIR sensitivity level Green: Flashes 1-5 times according setting to the selected level Optics Two Mironel Mirror/W Fresnel optics with mechanical Pet / Creep Zone Alarm detection Red: ON for 3 seconds Coverage Booting/Tamper close Green/Red alternating flashes for 45 seconds 16 meters/52 feet; 90° - complies with EN50131-2-2 Grade 3 Anti-Masking Active IR with Dual detectors, blocking items up to 30cm and lens applied materials including clear lacquer; meets and exceeds EN50131-2-2 Grade 3 Pet Immunity Pet up to 50cm will not be detected Single/Dual Edge Infrared detection requires entry or exit in single-mode; in Dual-edge, entry and exit is required for both detectors Creep Zone Mechanically selectable Creep Zone detection 1.5m/4ft. (cancels Pet Immunity when active) Power Input 2 x 1.5 AA Alkaline batteries, up to 3 years for normal use with Active AntiMask detection Current Consumption Standby: 158uA, Max.: 18.3mA Low Battery 2.2V Frequency 433 or 868 MHz, internally selectable Operating Temperature -35º to 50º C (-31º to 122º F) Relative humidity 95% non-condensing Tamper Dual - Cover and Wall Dimensions 128 x 62 x 54 mm/ 5.1 x 2.4 x2.1 in Weight 120 gr/ 0.3 lb 160 gr / 0.4 lb (with batteries) Certifications CE, EN50131-2-2 Grade 2, Class II, EN 50131-6 Type C Anti-mask detection Flashes orange rapidly (pre-alarm state) and then flashes when in alarm. Beam Patterns Top View 90˚ 16m 14m 12m 10m 8m (52 ft) 6m 4m 2m 0m 2m 4m 6m 8m 10m 1.5m 60 cm 1.5m Creep Creep Zone Zone 12m 14m 16m (52 ft) Side View * Read installation height note* 2.8m 2.4m 2.1m Optimal 2.8m 2.8m 2.4m 2.4m 2.1m 2.1m Optimal Optimal 60cm 1.5m Creep Zone Both Detectors 3m Detector 1 5.5m Detector 2 10m 12m Pet Immune ON 16m (52 ft) Pet Immune OFF Warranty For complete warranty information on this product, please refer to the Limited Warranty Statement is found on the website: www.paradox.com/terms or contact your local distributor. Specifications may change without prior notice. Patents US, Canadian and international patents may apply. Paradox is a trademark or registered trademark of Paradox Security Systems paradox.com NV75MR-EI00/c 12/2016 FCC and Industry Canada Compliance Statement This device complies with FCC Rules Part 15 and with Industry Canada license exempt RSS standard(s). Operation is subject to two conditions: 1.This device may not cause harmful interference 2.This device must accept any interference that may be received or that may cause undesired operation. Le present appareil est conforme aux CNR d'Industrie Canada applicables aux appareils radio exempts de licence. L'exploitation est autorisee aux deux conditions suivantes : 1.l'appareil ne doit pas produire de brouillage, et 2.l'utilisateur de l'appareil doit accepter tout brouillage radioelectrique subi, meme si le brouillage est susceptible d'en compromettre le fonctionnement. FCC ID: KDYNV75MR IC: 2438A-NV75MR FCC WARNING This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: • Reorient or relocate the receiving antenna. • Increase the separation between the equipment and the receiver. • Connect the equipment into an outlet different from that to which the receiver is connected. • Consult the dealer or an experienced radio/TV technician for help. Changes or modifications to this equipment not expressly approved by the party responsible for compliance (Paradox Security Systems Ltd.) could void the user's authority to operate the equipment. paradox.com NV75MR-EI00/c 12/2016
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.6 Linearized : Yes Author : jonathanb Create Date : 2016:03:22 08:57:41Z Modify Date : 2017:01:24 15:22:29+02:00 Language : en XMP Toolkit : Adobe XMP Core 5.2-c001 63.139439, 2010/09/27-13:37:26 Creator Tool : FrameMaker 12.0.4 Metadata Date : 2017:01:24 15:22:29+02:00 Format : application/pdf Title : NV75MR-EI00.fm Creator : jonathanb Producer : Acrobat Distiller 10.1.16 (Windows) Document ID : uuid:26424c73-ef13-4955-8a8b-5dba490e2d20 Instance ID : uuid:f488e0ce-328e-42a1-9530-800a1e0fb41a Page Mode : UseOutlines Page Count : 3EXIF Metadata provided by EXIF.tools