Paxton Access 337937 Net2 Entry - VR Panel, surface mount User Manual manual
Paxton Access Ltd Net2 Entry - VR Panel, surface mount manual
manual
05/10/2013 Paxton Ins-30208-US Net2 Entry - Vandal Resistant Panel Technical Support 1.800.672.7298 Technical help is available: supportUS@paxton-access.com Monday - Friday from 02:00 AM - 8:00 PM (EST) Documentation on all Paxton products can be found on our web site - http://www.paxton-access.com/ Description of product The Net2 Entry panel is a robust door entry panel incorporating both door entry and access control functions. It is powered using power over Ethernet (PoE) and communicates with the other elements of the system using IPv6, providing 'plug and play' installation. Each panel is associated with a Net2 Entry control unit which is the interface to the door hardware. The panel is equipped with a keypad and a proximity token reader. A resident can use either the keypad or a token to gain entry. Installers gain access to the menu options using an engineer code or an engineer token. Net2 software is used to administer the access control functions. It must be v4.25 or a later version. 1. 2. 3. 4. 5. 6. 7. 8. Speaker Proximity reader Keypad LCD display IR LEDS for night time operation Microphone Color camera Light sensor Page 1 Installation To achieve the best camera performance, try to mount the panel facing away from direct sun or a bright light source. This will also help the user to read the LCD display. Decide how the units are to be connected. You can either run your own wired network or share the buildings existing data network. If using the owners network, the system uses IPv6 protocol and PoE (Power over Ethernet) so the network must support this switch type. Paxton recommend that the network cable is run to each location and terminated in a network box. A patch cable should then be used to link the unit to the network. This makes unit replacement or removal for building maintenance much easier. Where it is not practical to run a patch cable to the rear of the unit, it can be directly wired to the network cable via the supplied IDC module. Mounting The unit is supplied with the surface mount backbox. A flush mount backbox is also available (PN:337-857). Screws and wall plugs are provided in the fitting kit. A single hole must be drilled for the single data/power connection. Electrical power is supplied via the data cable (PoE) from the Net2 Entry controller. 1. 2. 3. 4. 5. Determine the height for the camera and then mark and drill the cable hole with reference to the diagram. Complete the installation of the mounting backbox - Surface or Flush. Connect the Net2 Entry panel to controller. Mount the panel in its backbox. Power up the panel from controller supply (PoE) or external PoE switch. The display will ask you to set up an Engineer code. The panel checks to see if any monitors also exist on the network. Any that are detected will now have the engineer code loaded and will store the panel ID that called them SURFACE BACKBOX FLUSH BACKBOX 132 Ø 5 x8 171 136 32.5 30.5 330 368 79 40.5 85 44 44 51 51 329 79 75 75 Ø 5 x8 39.5 79 39.5 79 Page 2 SURFACE MOUNT FLUSH MOUNT Page 3 Use the up and down arrows on the panel to view all the menu options. Use the key to Cancel Initializing a new system The first time the system is powered up the panel will request that the Language to be used is confirmed. It then asks for an Engineer code to be set up. Enter the required code and press the bell key. Confirm the code and press bell to complete the process. The Net2 Entry system uses a separate control unit to operate the door. To associate a panel with its control unit, the Serial Number of the control unit must be entered. Only one panel can be associated with a control unit. Multiple panel installations require a control unit for each panel. Calling a Monitor unit As Monitor units are added to the system, they will automatically become active. To call a monitor type in the monitor ID and press the Bell button. Single Occupancy When only one monitor ID is in use, pressing the Bell button will call the monitor. How an Occupant gains entry For access control, a Net2 system is required for administration. Once set up, a user can gain entry by presenting their token to the panel. For PIN or Code entry, the # key must be pressed first before pressing the numbers on the panel. Using the Engineer menu To access the Engineer menu from the default screen press *, enter the Engineer code and press the Bell button. Page 4 Use the up and down arrows on the panel to view all the menu options. 1. Door open time Use the key to Cancel from the Engineer menu - Press key 1. This is the time period that the lock will stay released once the open door button has been pressed on a monitor. This value may only be changed when not administered by Net2. 2. Volume settings 1. Set voice volume from the Engineer menu - Press key 2 from Volume settings menu - Press key 1 This sets the volume of the entry panel speaker. Use the up and down arrow buttons to adjust then press Bell. 2. Set keypress tone from Volume settings menu - Press key 2 This sets the tone that the entry panel will make when a key is pressed. Press 1. Click Press 2. Beep Press 3. Silent 3. Set door open tone from Volume settings menu - Press key 3 This sets the tone that the entry panel will make while the lock is released. Press 1. Beep Press 2. Buzz Press 3. Silent 3. Call timeout from the Engineer menu - Press key 3 This is the maximum time period that one call can last. This ensures that the entry panel is not held busy if a call is not terminated correctly. 4. View options from the Engineer menu - Press key 4 1. Allow video without being called from View options menu - Press key 1 This allows the camera to be viewed at any time even when not being used to grant access. Press 1. Yes Press 2. No 2. Allow audio without being called from View options menu - Press key 2 This allows the microphone to be turned on at any time even when not being used to grant access. Press 1. Yes Press 2. No 3. Open the Door without being called from View options menu - Press key 3 This allows the 'Unlock door' button to be used while viewing with the camera. The visitor does not need to initiate the call. Press 1. Yes Press 2. No Page 5 5. Panel settings 1. Set control unit from the Engineer menu - Press key 5 from Panel settings menu - Press key 1 This sets the control unit that the Net2 Entry panel is associated with. Enter the Serial Number of the control unit and then press Bell. 2. Factory reset from Panel settings menu - Press key 2 This returns the Entry panel to Factory settings Press 1. Yes Press 2. No 3. Backlight from Panel settings menu - Press key 3 This sets when the Entry panel backlight will be on. Press 1. Always on Press 2. Never on Press 3. Only on in low light 4. Video quality from Panel settings menu - Press key 4 This option slows the video rate to reduce the load on busy networks. Press 1. Low - busy networks Press 2. Med - small networks Press 3. High - private wiring 6. Operating Mode 1. Number only from the Engineer menu - Press key 6 from Set Operating mode menu - Press key 1 This requires the visitor to enter the number without the assistance of a list. 2. Numbered list from Set Operating mode menu - Press key 2 This displays the monitor IDs to the visitor as a numeric list with its name which they can scroll or enter the number. Menu will also respond to numeric input. 3. Text selection from Set Operating mode menu - Press key 3 This displays the monitor names to the visitor in alphabetical order which they can scroll through and select. Page 6 7. Engineer Access 1. Set Engineer Code from the Engineer menu - Press key 7 from Engineer Access menu - Press key 1 This allows the Engineer to change the Engineer code 2. Change Engineer Token from Engineer Access menu - Press key 2 This allows the engineer to add / change the Engineer token The engineer can create a token that can be presented to the proximity reader instead of using the engineer code to gain access to the Engineer Menu. 8. Language from the Engineer menu - Press key 8 This displays the language options available for this monitor. 9. About from the Engineer menu - Press key 9 This displays information about the panel. (e.g. the current version number) Page 7 Specifications Dimensions Electrical Width Height Depth 4 inch 11 inch 1 1/4 inch Min Max Power over Ethernet (POE) power rating 12.95W IEEE 802.3af class 0 1Mb/s multicast per panel during call Communication Ethernet bandwidth requirement 100kb/s multicast 100 Panels per system Min Features Max Camera system Full color I/R illumination Yes Audio system Two way Display Backlit LCD 125k/Hz Proximity reader Environment Operating temperature Min Max - 20 °C ( - 4 °F ) 50 °C ( 122 °F ) IP Rating Vandal resistance IP55 Paxton Access tokens External use High Product compliance and limitations Wiring methods shall be in accordance with the National Electrical Code (ANSI/NFPA70), local codes, and the authorities having jurisdiction. This device complies with Industry Canada licence-exempt RSS standard(s). Operation is subject to the following two conditions: (1) this device may not cause interference, and (2) this device must accept any interference, including interference that may cause undesired operation of the device. This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. Page 8
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.4 Linearized : Yes Create Date : 2013:05:10 12:26:57+01:00 Creator : Adobe InDesign CS6 (Windows) Modify Date : 2013:05:10 14:47:01+01:00 Tagged PDF : Yes XMP Toolkit : Adobe XMP Core 5.2-c001 63.139439, 2010/09/27-13:37:26 Metadata Date : 2013:05:10 14:47:01+01:00 Creator Tool : Adobe InDesign CS6 (Windows) Instance ID : uuid:d2528a75-adcf-46bb-9429-b6bde1256114 Original Document ID : adobe:docid:indd:819f26dc-d01d-11dd-90d3-83f836e1e099 Document ID : xmp.id:4E9E047E64B9E211A4EFB62AE5D277AA Rendition Class : proof:pdf Derived From Instance ID : xmp.iid:4D9E047E64B9E211A4EFB62AE5D277AA Derived From Document ID : xmp.did:7970A05779D1E111ADF0AEFBF671FF76 Derived From Original Document ID: adobe:docid:indd:819f26dc-d01d-11dd-90d3-83f836e1e099 Derived From Rendition Class : default History Action : converted History Parameters : from application/x-indesign to application/pdf History Software Agent : Adobe InDesign CS6 (Windows) History Changed : / History When : 2013:05:10 12:26:58+01:00 Format : application/pdf Producer : Adobe PDF Library 10.0.1 Trapped : False Page Count : 8EXIF Metadata provided by EXIF.tools