PAGE 1Ins-40049-US   PROXIMITY metal reader - ULMountingThis reader is designed to read Paxton Tokens (Hitag2) and EM4100 tokens.It will provide Clock and Data output for Paxton (Net2 / Switch2). Mounted on metal surfaceSuitabilitySecurity sensitive doors Wet environmentsTechnical SupportTechnical help is available:     Monday - Friday from 02:00 AM - 8:00 PM (EST)1.800.672.7298 supportUS@paxton-access.comDocumentation on all Paxton products can be found on our web site - http://www.paxton-access.com/Readers mounted togetherPaxton03/15/2012For instructions in alternative languages - http://paxton.info/1000
PAGE 2Cable extensionsRed 12v dc Brown Orange Green Yellow Blue Mauve Black/White Brown Yellow Reader 1 Orange Keypad 1 +12v 0v N.C. N.O. Com N.C. N.O. Com Alarm Output 0v Contact 0v Exit 0v Tamper PSU Rx Tx Relay 1 Relay 2 Exit Contact Tamper PSU OK 5v 12v Red Brown Orange Green Yellow Blue Mauve Black/White Brown Yellow Orange Reader 2 Keypad 2 Power Relay 1 Relay 2 Inputs Network CAT5 cable coding White/Green Green White/Orange Orange 1 2 3 4 Screen or spare cores from network cable CAUTION: for 12v d.c. readers only. For correct connection of old 5v readers, refer to  instructions. Serial number 241821   Test ID: 012345678901    z-1440 3  2 4 8 9 8  0 0 0 0 0  4  x R Green White/Green  1 Screen or spare cores from  network cable White/O r ang e  3 O r ang e  4 K 1   r e d a e R  d a p y e  1 12V Alarm Output R  l e a y 2 N.C. N. O . Com N.C. N. O . Com 0 V 0V Exit 0 V PSU 0V Contact T ampe r R  l e a y 1 V 2 1 V 5 K O T  e p m a  r t c a t n o C t i x E R  l e a y 1 x T U S P K eypad 2  Reader 2 s t u p n I  P  e w o  r R  l e a y 2 C A  n i d o c   e l b a c   5 T  g k r o w t e N +V out Red LED Amber LED Green LED Data/D0 Clock/D1 Media Detect 0V out Data Load Clock t u o   V + D E L   d e R D E L   r e b m A D E L   n e e r G 0 D / a t a D 1 D / k c o l C t c e t e D   a i d e M t u o   V 0 a t a D d a o L k c o l C Net2 2 WiringUse Max length TypeReader / Keypad 500 feet 8 core shielded, Beldon 9538, Alpha 1298C (22AWG)  or equivalentCable SpecicationPart number Description390-747-US PROXIMITY metal readerOptionsNet2 control unit Switch2 control unitRed 12VBrownOrangeGreenYellowBlueMauveExitContactBlackCard reader or keypad 12v 0vN.C.N.O.ComBellPowerDoor relayAlarmwitch2SControlunitInputsCAUTION: For 12V d.c. readers only. For correct connection of old readers, refer to instructions.Card reader or keypad Inputs Door relay  Power Alarm Bell 12V 0V N.C. N.O. COM CAUTION:  For 12Vd.c.  readers only.  For correct  connection of old readers,  refer to instructions.  Contact Exit Switch2 12V Red LED Amber LED Green LED Data/D0 Clock/D1 Media Detect 0V
PAGE 3Reader installation and testFollowing the completed installation of this equipment, no further maintenance or testing is required.It is advisable to ensure that any third party backup power supplies or recovery procedures are checked regularly to ensure that the operation of the Paxton system is not compromised.MaintenanceFCC ComplianceThis device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Changes or modications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. Drill a hole in the surface for the rear data cable. Secure the mounting plate to the surface with four screws as per tting diagram on page 1.  Suitable screws and xings are provided for tting the plate to a wall.  Mount the reader on its backplate and secure with the security screws using the Allen key supplied.   Ensure the data cable has free access at the rear.The reader will bleep and all the LEDS should display after powering on the control unit.  Presenting a user card to the reader will cause the LEDs to briey change to a single Green or Red LED.Check the following FAQs section for assistance if any problems are encountered.Parts listPart number DescriptionFitting Kit  fk1-058 4 off  - M5x20 Security button socket pin head machine screw4 off  - No8 x 11/2in pozi round woodscrew - zinc4 off - Wall plugs 35mm, red1 off  - 3mm socket pin head Allen keyThe use of any add-on, expansion, memory or other module manufactured or supplied by the manufacturer's representative will invalidate the CAN/ULC-S319 certication. For CAN/ULC-S319 installations, terminals, leads and wiring methods must comply with CSA, C22.1, Canadian electrical code, Part 1, safety standards for electrical installations. Product compliance and limitations To comply as a UL listed installation, the following conditions must apply:-Server based functions  (Antipassback, Time and Attendance, etc) have not been evaluated by UL and cannot be used for UL 294 installations.The use of Wiegand readers and the conguration software has not been evaluated by 'UL' Wiring: - Where an equivalent cable / wire is used it must be ' UL Listed '              All interconnecting devices must be UL Listed.Wiring methods shall be in accordance with the National Electrical Code (ANSI/NFPA70), local codes, and the authorities having jurisdiction.This device complies with Industry Canada licence-exempt RSS standard(s). Operation is subject to the following two conditions: (1) this device may not cause interference, and (2) this device must accept any interference, including interference that may cause undesired operation of the device.
PAGE 4-35 °C  ( -31 °F ) +66 °C  ( + 151 °F ) Waterproof IPX710 feet 12V DC110 mA125 kHz600 µs2 inch 11/2 inch3 inch 3 inch 1 inchVoltageClock and data bit period Carrier frequencySpecicationsOperating temperatures - all itemsElectricalEnvironment DimensionsMin MaxWidth Height DepthCurrentCable lengthRead Range Token Keyfob Hands Free TokenHere is the list of topics about this product that receive the most technical support inquiries. We list them here to help you speed up the installation and trouble shooting process.Outdoor use Min MaxTechnical Help1 - Readers/Keypads not working.Q- Software settings - Conrm that the settings of the reader or keypad are correct. Q- Connections - Check the wiring and integrity of the connectors.  If possible, test this reader on the other port.Q- Extended cable - Belden 9538/9540 should be used up to a maximum of 500 feet. Twisted pair alarm cable shouldQ  not be used. To conrm that an extended reader cable is not at fault, wire the reader directly to the port.Q- Supply voltage - Conrm that the voltage is within specication. (see table) Q- User token - Conrm that the user token used for testing is OK by presenting it to a known working reader.Q- Interference - Conrm whether the reader works when tested 'in hand' and not mounted on the wall. Q  PROXIMITY readers should not be mounted back to back or close to other RF devices.2 - Readers / Keypads - Extending cable.QOnly Belden CR9538 / 9540 or a UL equivalent can be used for cable extensions. The maximum run is 500 feet.3 - Net2 - Using a door reader as a desktop reader. QIt is possible to congure a door reader to operate as a desktop reader: Q1 - Select the doors menu in the left hand Net2 pane.Q2 - Click on the door you wish to change the reader to act as a desktop reader.Q3 - Under the relevant reader tab, change the reader operating mode to 'Desktop Reader'.Q4 - The PC displays 'Would you like to accept desktop reader events from this reader at the PC?' ; click 'Yes'Q     Now when you present a blank or existing token to that reader it will allow you to add this new token or editQ     the existing one.   NOTE:QRemember to return the operating mode to the original setting once the cards have been readQ             or users will not be able to gain access through the reader. Q KP Reader - Ensure that Keypad type is set to 'None', otherwise the Desktop reader option will not be available.4 - Net2.  What to do if a user has no access - Check the reader LED's when a card is shown. Q- No LED's - the reader has no power. Q- No change in display - try the card on a known working reader. If there is still no response, replace the card. Q- Green LED ashing when a card is presented;  check relay 1 LED to check for activity and also the lock wiring. Q- Red LED is ashing when a card is presented;  check the validity of the user at the PC. Q   Check user's access level and ensure they should have access by clicking on Current Validity. Q   Check the 'Expires end' date and conrm this has not been past. Q- Reinstate the ACU from the doors screen. Select the ACU's you wish to reinstate and then click OK.Not Compatible