Paxton Access 390135 Proximity Panel Mount Reader User Manual INSTRUCTION PROXIMITY panel mount reader UL

Paxton Access Ltd Proximity Panel Mount Reader INSTRUCTION PROXIMITY panel mount reader UL

Contents

manual 2

PAGE 1Ins-40078-US   PROXIMITY panel mount reader - ULMountingCompatible with hands free tokensSuitabilitySecurity sensitive doors Wet environmentsTechnical SupportTechnical help is available:     Monday - Friday from 02:00 AM - 8:00 PM (EST)1.800.672.7298 supportUS@paxton-access.comDocumentation on all Paxton products can be found on our web site - http://www.paxton-access.com/This reader is designed to read Paxton Tokens (Hitag2) and EM4100 tokens.It will provide Clock and Data output for Paxton (Net2 / Switch2). Readers mounted togetherbetween readers12 inchesPaxton03/14/2012For instructions in alternative languages - http://paxton.info/1000
PAGE 2Cable extensionsRed 12v dc Brown Orange Green Yellow Blue Mauve Black/White Brown Yellow Reader 1 Orange Keypad 1 +12v 0v N.C. N.O. Com N.C. N.O. Com Alarm Output 0v Contact 0v Exit 0v Tamper PSU Rx Tx Relay 1 Relay 2 Exit Contact Tamper PSU OK 5v 12v Red Brown Orange Green Yellow Blue Mauve Black/White Brown Yellow Orange Reader 2 Keypad 2 Power Relay 1 Relay 2 Inputs Network CAT5 cable coding White/Green Green White/Orange Orange 1 2 3 4 Screen or spare cores from network cable CAUTION: for 12v d.c. readers only. For correct connection of old 5v readers, refer to  instructions. Serial number 241821   Test ID: 012345678901    z-1440 3  2 4 8 9 8  0 0 0 0 0  4  x R Green White/Green  1 Screen or spare cores from  network cable White/O r ang e  3 O r ang e  4 K 1   r e d a e R  d a p y e  1 12V Alarm Output R  l e a y 2 N.C. N. O . Com N.C. N. O . Com 0 V 0V Exit 0 V PSU 0V Contact T ampe r R  l e a y 1 V 2 1 V 5 K O T  e p m a  r t c a t n o C t i x E R  l e a y 1 x T U S P K eypad 2  Reader 2 s t u p n I  P  e w o  r R  l e a y 2 C A  n i d o c   e l b a c   5 T  g k r o w t e N +V out Red LED Amber LED Green LED Data/D0 Clock/D1 Media Detect 0V out Data Load Clock t u o   V + D E L   d e R D E L   r e b m A D E L   n e e r G 0 D / a t a D 1 D / k c o l C t c e t e D   a i d e M t u o   V 0 a t a D d a o L k c o l C Net2 2 WiringUse Max length TypeReader / Keypad 500 feet 8 core, shielded -  Beldon 9538, Alpha 1298C (22AWG)  or equivalentCable SpecicationPart number Description390-135-US PROXIMITY panel mount readerOptionsNet2 control unit Switch2 control unitRed 12VBrownOrangeGreenYellowBlueMauveExitContactBlackCard reader or keypad 12v 0vN.C.N.O.ComBellPowerDoor relayAlarmwitch2SControlunitInputsCAUTION: For 12V d.c. readers only. For correct connection of old readers, refer to instructions.Card reader or keypad Inputs Door relay  Power Alarm Bell 12V 0V N.C. N.O. COM CAUTION:  For 12Vd.c.  readers only.  For correct  connection of old readers,  refer to instructions.  Contact Exit Switch2 12V Red LED Amber LED Green LED Data/D0 Clock/D1 Media Detect 0V
PAGE 3Following the completed installation of this equipment, no further maintenance or testing is required.It is advisable to ensure that any third party backup power supplies or recovery procedures are checked regularly to ensure that the operation of the Paxton system is not compromised.MaintenanceDescriptionNot required Reader ts to studs on customer faciaParts KitReader installation and testThe panel mount reader is designed to t into a door entry panel. It ts behind a reader aperture of industry standard size (40 mm x 40 mm) and is supplied with a polycarbonate window to match.  See front page for tting detail.Holes are provided in each corner to t over 4 posts set in a 49 mm square formation.  Fixings are not provided as they will normally be supplied with the panel.When powered up, the reader will beep and all the LED's should display.  Presenting a user card to the reader will cause the LED's to briey change to a single Green or Red LED.Check the following FAQs section for assistance if any problems are encountered.FCC ComplianceThis device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Changes or modications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. The use of any add-on, expansion, memory or other module manufactured or supplied by the manufacturer's representative will invalidate the CAN/ULC-S319 certication. For CAN/ULC-S319 installations, terminals, leads and wiring methods must comply with CSA, C22.1, Canadian electrical code, Part 1, safety standards for electrical installations. Product compliance and limitations To comply as a UL listed installation, the following conditions must apply:-Server based functions  (Antipassback, Time and Attendance, etc) have not been evaluated by UL and cannot be used for UL 294 installations.The use of Wiegand readers and the conguration software has not been evaluated by 'UL' Wiring: - Where an equivalent cable / wire is used it must be ' UL Listed '              All interconnecting devices must be UL Listed.Wiring methods shall be in accordance with the National Electrical Code (ANSI/NFPA70), local codes, and the authorities having jurisdiction.This device complies with Industry Canada licence-exempt RSS standard(s). Operation is subject to the following two conditions: (1) this device may not cause interference, and (2) this device must accept any interference, including interference that may cause undesired operation of the device.
PAGE 412V DC150 mA125 kHz600 µs-35 °C  ( -31 °F ) +66 °C  ( + 151 °F )IPX710 feet2” 11/2”2 1/4 ”2 1/4 ”11/16 ”40 mm  (1 19/32”) 40 mm  (1 19/32”) -49 mm  (1 30/32”) 49 mm  (1 30/32”)Here is the list of topics about this product that receive the most technical support inquiries. We list them here to help you speed up the installation and trouble shooting process.Technical Help1 - Readers/Keypads not working.Q- Software settings - Conrm that the settings of the reader or keypad are correct. Q- Connections - Check the wiring and integrity of the connectors.  If possible, test this reader on the other port.Q- Cable - To conrm that an extended reader cable is not at fault, wire the reader directly to the port.Q- Supply voltage - Conrm that the voltage is within specication. (see table)Q- User token - Conrm that the user token used for testing is OK by presenting it to a known working reader.Q- Interference - Conrm whether the reader works when tested 'in hand' and not mounted on the wall. Q  Ensure PROXIMITY readers are not mounted back to back or that there is no interference from other RF devices. 2 - Net2.  What to do if a user has no access - Check the reader LEDs when a card is shown. Q- No LEDs - the reader has no power. Q- No change in display - try the card on a known working reader. If there is still no response, replace the card. Q- Green LED ashing when a card is presented;  check relay 1 LED to check for activity and also the lock wiring. Q- Red LED is ashing when a card is presented;  check the validity of the user at the PC. Q   Check user's access level and ensure they should have access by clicking on Current Validity. Q   Check the 'Valid Until' date and conrm this has not expired. Q- Reinstate the ACU from the doors screen. Select the ACU's you wish to reinstate and then click OK. 3 - Switch2 - Adding an additional card pack.QYou need to be in possession of the original enrolment card. Present the original enrolment card to the reader andQthe Amber LED will ash, Green & Red LEDs will be off, then present the Enrolment card from the new card pack;Qthe reader will beep and all LEDS will be lit. The additional cards will now be valid. Repeat this with each readerQand with any additional card packs. Any valid enrolment card can be used to add further packs. This is the sameQfor enrolling function card packs onto a system.4 - Switch2 - How to reset the controller.Q1.  Disconnect the power and remove the wires from the Green and Mauve terminalsQ2.  Insert a wire link between the Green and Mauve terminalsQ3.  Reconnect the power (the unit will bleep 4 times)Q4.  Disconnect the power and remove the link wire, reconnect the Green and Mauve wiresQ5.  Reconnect the power (the unit will bleep 3 times per second). The unit is ready to be enrolled.VoltageClock and data bit period Carrier frequencySpecicationsOperating temperatures - all itemsElectricalEnvironment DimensionsMin MaxWidth Height DepthCurrentCable lengthRead Range Token Keyfob Hands Free TokenOutdoor use Min MaxPanel mount reader Window sizeMounting studs - Square formation See front page for positionNot CompatibleReader xings are in metric to match industry standard access panel readersWaterproof