Paxton Access 390135 Proximity Panel Mount Reader User Manual INSTRUCTION PROXIMITY metal reader UL
Paxton Access Ltd Proximity Panel Mount Reader INSTRUCTION PROXIMITY metal reader UL
Contents
- 1. manual 1
- 2. manual 2
manual 1
PAGE 1
Ins-40049-US PROXIMITY metal reader - UL
Mounting
This reader is designed to read Paxton Tokens (Hitag2) and EM4100 tokens.
It will provide Clock and Data output for Paxton (Net2 / Switch2).
Mounted on metal surface
Suitability
Security sensitive doors Wet environments
Technical Support
Technical help is available: Monday - Friday from 02:00 AM - 8:00 PM (EST)
1.800.672.7298 supportUS@paxton-access.com
Documentation on all Paxton products can be found on our web site - http://www.paxton-access.com/
Readers mounted together
Paxton
03/15/2012
For instructions in alternative languages - http://paxton.info/1000
PAGE 2
Cable extensions
Red 12v dc
Brown
Orange
Green
Yellow
Blue
Mauve
Black/White
Brown
Yellow
Reader 1
Orange
Keypad 1
+12v
0v
N.C.
N.O.
Com
N.C.
N.O.
Com
Alarm Output
0v
Contact
0v
Exit
0v
Tamper
PSU
Rx
Tx
Relay 1
Relay 2
Exit
Contact
Tamper
PSU
OK
5v
12v
Red
Brown
Orange
Green
Yellow
Blue
Mauve
Black/White
Brown
Yellow
Orange
Reader 2
Keypad 2
Power
Relay 1 Relay 2 Inputs
Network
CAT5 cable coding
White/Green
Green
White/Orange
Orange
1
2
3
4
Screen or spare cores
from network cable
CAUTION: for 12v d.c. readers only. For
correct connection of old 5v readers, refer to
instructions.
Serial number
241821
Test ID: 012345678901
z-1440
3 2 4 8 9 8 0 0 0 0 0 4
x R
Green
White/Green 1
Screen or spare cores from
network cable
White/O r ang e 3
O r ang e 4
K 1 r e d a e R d a
p y e 1
12V
Alarm Output
R l e a y 2
N.C.
N. O .
Com
N.C.
N. O .
Com
0 V
0V
Exit
0 V
PSU
0V
Contact
T ampe r
R l e a y 1
V 2
1
V
5
K O
T e p
m a r
t c a t n o C
t
i
x E
R l e a y 1
x T
U
S
P
K eypad 2 Reader 2
s t u p n I P e w o r
R l e a
y 2
C A n i d o c
e
l b a c
5 T g
k r
o w
t e N
+V out
Red LED
Amber LED
Green LED
Data/D0
Clock/D1
Media Detect
0V out
Data
Load
Clock
t u
o V +
D E L d e R
D E L
r e
b m A
D E L n e e r G
0 D / a t a
D
1 D / k c
o l C
t c e t e D
a i d e M
t u o V 0
a t a D
d a o L
k c o l C
Net2
2
Wiring
Use Max length Type
Reader / Keypad 500 feet 8 core shielded, Beldon 9538, Alpha 1298C (22AWG) or equivalent
Cable Specication
Part number Description
390-747-US PROXIMITY metal reader
Options
Net2 control unit
Switch2 control unit
Red 12V
Brown
Orange
Green
Yellow
Blue
Mauve
Exit
Contact
Black
Card reader or keypad
12v
0v
N.C.
N.O.
Com
Bell
PowerDoor relay
Alarm
witch
2
S
Control
unit
Inputs
CAUTION: For 12V d.c. readers only.
For correct connection of old readers,
refer to instructions.
Card reader or keypad
Inputs
Door relay Power
Alarm
Bell
12V
0V
N.C.
N.O.
COM
CAUTION: For 12Vd.c.
readers only. For correct
connection of old readers,
refer to instructions.
Contact
Exit
Switch2
12V
Red LED
Amber LED
Green LED
Data/D0
Clock/D1
Media Detect
0V
PAGE 3
Reader installation and test
Following the completed installation of this equipment, no further maintenance or testing is required.
It is advisable to ensure that any third party backup power supplies or recovery procedures are checked regularly
to ensure that the operation of the Paxton system is not compromised.
Maintenance
FCC Compliance
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:
(1) this device may not cause harmful interference, and (2) this device must accept any interference
received, including interference that may cause undesired operation. Changes or modications not expressly
approved by the party responsible for compliance could void the user's authority to operate the equipment.
Drill a hole in the surface for the rear data cable. Secure the mounting plate to the surface with four screws as per
tting diagram on page 1. Suitable screws and xings are provided for tting the plate to a wall.
Mount the reader on its backplate and secure with the security screws using the Allen key supplied. Ensure the
data cable has free access at the rear.
The reader will bleep and all the LEDS should display after powering on the control unit. Presenting a user card to
the reader will cause the LEDs to briey change to a single Green or Red LED.
Check the following FAQs section for assistance if any problems are encountered.
Parts list
Part number Description
Fitting Kit fk1-058 4 off - M5x20 Security button socket pin head machine screw
4 off - No8 x 11/2in pozi round woodscrew - zinc
4 off - Wall plugs 35mm, red
1 off - 3mm socket pin head Allen key
The use of any add-on, expansion, memory or other module manufactured or supplied by the manufacturer's
representative will invalidate the CAN/ULC-S319 certication.
For CAN/ULC-S319 installations, terminals, leads and wiring methods must comply with CSA, C22.1, Canadian
electrical code, Part 1, safety standards for electrical installations.
Product compliance and limitations
To comply as a UL listed installation, the following conditions must apply:-
Server based functions (Antipassback, Time and Attendance, etc) have not been evaluated by UL and cannot be used
for UL 294 installations.
The use of Wiegand readers and the conguration software has not been evaluated by 'UL'
Wiring: - Where an equivalent cable / wire is used it must be ' UL Listed '
All interconnecting devices must be UL Listed.
Wiring methods shall be in accordance with the National Electrical Code (ANSI/NFPA70), local codes, and the
authorities having jurisdiction.
This device complies with Industry Canada licence-exempt RSS standard(s). Operation is subject to the following two
conditions: (1) this device may not cause interference, and (2) this device must accept any interference, including
interference that may cause undesired operation of the device.
PAGE 4
-35 °C ( -31 °F ) +66 °C ( + 151 °F )
Waterproof IPX7
10 feet
12V DC
110 mA
125 kHz
600 µs
2 inch 11/2 inch
3 inch 3 inch 1 inch
Voltage
Clock and data bit period
Carrier frequency
Specications
Operating temperatures - all items
Electrical
Environment
Dimensions
Min Max
Width Height Depth
Current
Cable length
Read Range Token Keyfob Hands Free Token
Here is the list of topics about this product that receive the most technical support inquiries.
We list them here to help you speed up the installation and trouble shooting process.
Outdoor use
Min Max
Technical Help
1 - Readers/Keypads not working.
Q- Software settings - Conrm that the settings of the reader or keypad are correct.
Q- Connections - Check the wiring and integrity of the connectors. If possible, test this reader on the other port.
Q- Extended cable - Belden 9538/9540 should be used up to a maximum of 500 feet. Twisted pair alarm cable should
Q not be used. To conrm that an extended reader cable is not at fault, wire the reader directly to the port.
Q- Supply voltage - Conrm that the voltage is within specication. (see table)
Q- User token - Conrm that the user token used for testing is OK by presenting it to a known working reader.
Q- Interference - Conrm whether the reader works when tested 'in hand' and not mounted on the wall.
Q PROXIMITY readers should not be mounted back to back or close to other RF devices.
2 - Readers / Keypads - Extending cable.
QOnly Belden CR9538 / 9540 or a UL equivalent can be used for cable extensions. The maximum run is 500 feet.
3 - Net2 - Using a door reader as a desktop reader.
QIt is possible to congure a door reader to operate as a desktop reader:
Q1 - Select the doors menu in the left hand Net2 pane.
Q2 - Click on the door you wish to change the reader to act as a desktop reader.
Q3 - Under the relevant reader tab, change the reader operating mode to 'Desktop Reader'.
Q4 - The PC displays 'Would you like to accept desktop reader events from this reader at the PC?' ; click 'Yes'
Q Now when you present a blank or existing token to that reader it will allow you to add this new token or edit
Q the existing one.
NOTE:QRemember to return the operating mode to the original setting once the cards have been read
Q or users will not be able to gain access through the reader.
Q KP Reader - Ensure that Keypad type is set to 'None', otherwise the Desktop reader option will not be available.
4 - Net2. What to do if a user has no access - Check the reader LED's when a card is shown.
Q- No LED's - the reader has no power.
Q- No change in display - try the card on a known working reader. If there is still no response, replace the card.
Q- Green LED ashing when a card is presented; check relay 1 LED to check for activity and also the lock wiring.
Q- Red LED is ashing when a card is presented; check the validity of the user at the PC.
Q Check user's access level and ensure they should have access by clicking on Current Validity.
Q Check the 'Expires end' date and conrm this has not been past.
Q- Reinstate the ACU from the doors screen. Select the ACU's you wish to reinstate and then click OK.
Not Compatible