LIGHTING
Corrosive elements. Combustible dusts.
Flammable gases and vapors. For proper
illumination in extreme conditions, you
need a company that pushes safety to
the extreme. Appleton has expanded
the boundaries of technology, efficiency
and performance to ensure your lighting
stays on – and safe. Because failure just
isn’t an option.
LIGHTING
Lighting
Lighting
Lighting
Description
Page
Enclosed and Gasketed — Area — HID
Mercmaster™ III Luminaires Family Tree
920
Mercmaster™ III Low Profile Luminaires
922
Mercmaster™ III HID 50—250 Watt Luminaires
941
Mercmaster™ III 400 Luminaire for Hazardous
and Wet Locations
976
ATX LN Series Wellglass Luminaires
995
Mercmaster™ II HID Luminaires
1005
Mercmaster™ Jr. Luminaires
1021
MMIII Low Profile
MMIII 50-250
MMIII 400
LN Series
MMII
MM Jr.
MM LED
MMIII Induction
MMIII Low Profile
Enclosed and Gasketed — Area — LED/Induction
Mercmaster™ LED Luminaires
1028
Mercmaster™ III Induction Luminaires
1037
Enclosed and Gasketed — Area — Fluorescent
Mercmaster™ III Low Profile Compact
Fluorescent Luminaires
1055
FV™ Series Nonmetallic Fluorescent Luminaires
1070
FR™ Enclosed and Gasketed; FZ™ and FD™
Hazardous Locations Luminaires
1075
ATX FE Series Nonmetallic Fluorescent
Luminaires
1081
ATX FL Series Light Duty Nonmetallic
Fluorescent Luminaires
1095
ATX FN Series Heavy Duty Nonmetallic
Fluorescent Luminaires
1100
RigMaster™ Metallic Fluorescent Luminaires
1106
RigMaster™ 304 Stainless Steel Fluorescent
Luminaires
1111
VRS™ and DRS™ Fluorescent Luminaires
1113
FV Series
FR Series
FL Series
FN Series
RigMaster™ Metallic
RigMaster™ 304 Stainless Steel — V
V
Enclosed and Gasketed — Area — Recessed Fluorescent
RE Series Recessed Fluorescent Luminaires
1119
VRS/DRS
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
913
Lighting
Lighting
Lighting
Description
Page
Enclosed and Gasketed — Area — Incandescent
Stylmaster™ Incandescent Luminaires
1126
V—51 Incandescent Luminaires
1135
REA™ 150 W Incandescent Luminaires
1147
®
Stylmaster
V—51
REA
Areamaster 100
Areamaster 250/400
Areamaster 1000
PN Series
Corroflood
Wallmaster — V
Enclosed and Gasketed — Floodlight
Areamaster™ 100 Wide—Beam Floodlights
1149
Areamaster™ 250/400 Integrally Ballasted
Floodlights
1155
Areamaster™ 1000 Floodlights
1162
ATX PN Series Floodlights – Zone 2, 21 and 22
1166
Corroflood™ 250/400 Stainless Steel Floodlights
1171
Wallmaster I/2 for Hazardous and Wet Locations
— Class I, Division 2/Zone 2
1174
V
TVA Obstruction, Approach and Boundary
Luminaires
1176
V
Stylmaster™ Strobe Luminaires
1180
Enclosed and Gasketed — Visual Signal
Enclosed and Gasketed — Emergency
Mercmaster™ III Emergency Battery Pack
1184
N2LS™ Series Emergency Luminaires
1200
Explosionproof — Area — HID
Code•Master Jr.™ HID Factory Sealed
Luminaires
1205
Code•Master 2™ HID Factory Sealed Luminaires
1216
TVA — V
Stylmaster Strobe MMIII Emergency
Battery Pack
N2LS
Explosionproof — Area — Induction
Code•Master 2™ Induction Lighting System
1231
Code•Master Jr
914
Code•Master 2™
Code•Master 2 Induction
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
Lighting
Lighting
Lighting
Description
Page
Explosionproof — Area — Fluorescent
Code•Master™ PLT Factory Sealed Luminaires
1240
APL Two and Four Lamp Fluorescent Factory
Sealed Luminaires
1252
EFU Fluorescent Factory Sealed Luminaires
1256
PAPL Portable Two and Four Lamp Fluorescent
Factory Sealed Luminaire
1260
ATX FD Series Cylindrical Fluorescent
Luminaires
1262
Code•Master PLT
APL
EFU
Explosionproof — Area — Incandescent
Code•Master™ Incandescent Factory Sealed
Luminaires
1269
A—51 Incandescent Factory Sealed Luminaires
1274
EDT Incandescent Luminaires
1288
®
PAPL
FD Series
Explosionproof — Floodlight
Code•Master 2™ HID Factory Sealed Floodlights
1289
EFL Series HID and Quartz Floodlights
1297
PB, PC & PL Series
1300
Explosionproof Floodlights
1306
V
Code•Master
A-51
EDT
Code•Master 2
EFL/PB/PC/PL
Explosionproof
Code•Master Strobe
TCH Series
AHL
Explosionproof — Visual Signal
Code•Master™ Factory Sealed Strobe
Luminaires
1308
Explosionproof — Portable
TCH Series Safety Flashlights
1314
AHL and EHL Incandescent Factory Sealed
Luminaires and Handlamps
1316
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
915
Lighting
Lighting
Lighting
Description
Page
Explosionproof — Emergency
Code•Master 2™ Emergency PLT Factory
Sealed Luminaires
1318
ELS Series Emergency Lighting System
1327
Increased Safety/Flameproof — Bulkhead
ATX HBE Series Round Bulkhead Luminaires
1133
ATX HBD Series Bulkhead Luminaires
1336
ATX HBN Series Round Bulkhead Luminaires
1341
ATX HBDC Series Cylindrical Bulkhead
Luminaires
1344
Code•Master 2 Emergency PLT
General Lighting — Area — High Bay
HBE/HBN Series
Baymaster 250/400™ High Bay Luminaires
1347
Baymaster Prismatic 250/400™ High Bay
Luminaires
1353
Super-Baymaster High Bay Luminaires
1358
Baymaster 1000™ High Bay Luminaires
1361
ELS Series
HBD Series
HBDC Series
V
General Lighting — Area — Low Bay
Lumenmaster 250™ Low Bay HID Prismatic
Luminaires
1365
Lumenmaster 400™ Low Bay HID Prismatic
Luminaires
1370
Baymaster
250/400
Baymaster
SuperPrismatic 250/400 Baymaster — V
Baymaster 1000
General Lighting — Area — Floodlights
Quartzlite™ 50 Floodlight
1375
Quartzlite™ 500/1500 Floodlight
1376
Areamaster Jr.™ HID Wide-Beam Floodlights
1379
Beam-Master™ Floodlights
1383
Lumenmaster 250
Quartzlite 50/500
916
Lumenmaster 400
Areamaster Jr
Beam-Master
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
Lighting
Lighting
Lighting
Description
Page
General Lighting — Area — Architectural
Wallmaster™ HPS/PSMH Luminaires
1386
Wallmaster™ 400 HPS/PSMH Luminaires
1390
Areamaster Squarelite™ 400 Sharp Cutoff
Luminaires
1395
Wallmaster
Wallmaster 400
Areamaster Squarelite
General Lighting — Area — Poles and Hangers
Round Tapered Steel Poles
1499
Hinged Steel Poles
1400
Square Tapered Steel Poles
1401
Square Steel Poles
1402
Floodlight Mounting Brackets
1403
UNJ
AL
JB
SSH
Flexible Fixture Hangers — Ordinary Location
AHG and UNJ Flexible Fixture Hangers
1407
AL Ball and Cushion Flexible Fixture Hangers
1408
JB and GS Flexible Fixture Hangers
1412
SSH Flexible Fixture Hangers
1414
SHC Flexible Fixture Hangers
1416
Flexible Fixture Hangers — Hook and Loop
1417
Flexible Fixture Hangers — Receptacle and
Hook and Loop
1420
Power Hook for Industrial High Bay Luminaires
1421
V
BKX Rigid Fixture Hangers
1422
CPU and EFHU Fixture Hangers
1424
V
Flexible Fixture Hangers, EXJF Couplings, ESD
and ESS Swivels
1427
EFHC and EFHCA Fixture Hangers and
Accessories
1430
GRF Conduit Outlet Boxes and Fixture Hanger
Covers and Canopies
1432
Fixture Hanger Bracket and Accessories
1434
Mounting Poles
SHC
Hook and Loop
Receptacle and
Power Hook — V
Hook and Loop
Flexible Fixture Hangers — Explosionproof
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
BKX
CPU
ESD
EFHC
GRF
Bracket
917
Lighting
Lighting
Lighting
Description
Page
McGill Temporary
HID Temporary Lighting
1436
String-O-Lights
1437
7000 Series Industrial Extension Lights
1439
7000-38 Series Industrial Extension Lights
1442
6000 Series Commercial-Duty Extension Lights
1443
5000 Series Industrial Extension Lights
1444
Industrial Extension Lights
1446
Handy Compact Fluorescent Work Light
1447
Rough Service Fluorescent Lamp
1448
Fluorescent Work Lights
1449
Battery Pack with Charger
1450
Fluorescent Industrial Extension Lights
1451
High Intensity Low-Voltage Extension Lights
1452
Mini-Powerpak Low-Voltage Extension Lights
1453
Fluorescent Hand Lamps — Explosionproof
1454
Tubular Fluorescent Inspection Light —
Explosionproof
1455
Industrial Extension Lights — Explosionproof
1456
Low-Voltage, High Intensity Hand Lamp —
Explosionproof
1457
HID Temp
String-O-Lights
7000/6000/5000
Extension Lights
Handy Compact
Rough Service
Fluorescent Work
Battery Pack
Industrial Extension
Lights
High Intensity
Mini-Powerpak
Hand Lamp
Tubular Inspection Light
Industrial Extension Lights
918
Low-Voltage,
High Intensity Hand Lamp
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
Lighting
Lighting
Lighting
Description
Page
McGill General
Incandescent Utility Lights
1458
Fluorescent Utility Lights
1460
McGill Lamp Protection
Protect-O-Sleeves
1461
Protect-O-Tubes
1463
Tubeloc Holders
1464
Protect-O-Globes
1465
Wire Lamp Guards and Wire Lamp Guard
Grounding Kit
1466
Utility Lights
Protect-O-Sleeves
Protect-O-Tubes
Tubeloc Holders
Protect-O-Globes
Wire Lamp Guard
McGill Lamp Changers
Fluorescent Lamp Changers
1467
Incandescent Lamp Changers
1468
Lamp Changer Accessories and Replacement
Parts
1470
Lamp Changers
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
919
Mercmaster™ III Luminaires Family Tree
Flexible
Pendant Mount
Pendant Mount
KPA75
KPA100
Ceiling Mount
25° Stan
KPC75
KPC100
KPCH75
KPCH100
K
K
Lighting: Enclosed and Gasketed — Area — HID
Lighting
KPAF75
KPAF100
Cone
Pendant Mount
POLYMERIC
REFRACTORS
NEMA 2 LPRF-2CP
NEMA 3 LPRF-3CP
NEMA 4 LPRF-4CP
NEMA 5 LPRF-5CP
MLBG SERIES
50 W-150 W HPS
50 W-175 W PSMH
Med. Base
26-84 W Fluorescent
5.50"/
139.7mm
• Fluorescent
• Metal Halide
100W Max.
(Lamp Extender
not required)
Standard Dome
CMR-4ST *
Deep Dome
CMR-4DD *
7.75"/
196.9mm
MLBR SERIES
50 W-150 W HPS
50 W-175 W PSMH
Med. Base
26-84 W Fluorescent
KPB SERIES
50 W-150 W HPS
100 W, 175 W,
200 W, 250 W PSMH (KPBG)
Mogul Base
5.50"/
139.7mm
Metal Halide
100W Max
Lamp Extender
30° Angle
CMR-4AN
GLASS REFRACTORS
Standard Dome Deep Dome
KR2-ST
KR2-DD
Standard Dome
CMR-4ST *
NEMA 1 LPG-R1
NEMA 3 LPG-R3
NEMA 5 LPG-R5
30° Angle
KR2-AN
POLYMERIC
REFRACTORS
NEMA 2 LPRF-2CP
NEMA 3 LPRF-3CP
NEMA 4 LPRF-4CP
NEMA 5 LPRF-5CP
KRG2
Refractor Guard
GLASS GLOBE
HID GLASS GLOBE
Clear
Amber
Blue
Green
Red
VPGL-1HR
VPGL-1AM
VPGL-1BL
VPGL-1GR
VPGL-1RE
5.63"/
143.0mm
GLASS GLOBE
Clear VPGL-3HR
Fluorescent
Clear VPGL-2HR
Amber VPGL-2AM
Blue VPGL-2BL
Green VPGL-2GR
Red VPGL-2RE
8.00"/
203.2mm
KGU1
HID
GlobeGuard
8.50"/
215.9mm
KGU2
Fluorescent
Globe Guard
(for 100 W HPS only)
Standard Dome
KR2-ST
Deep Dome
KR2-DD
GLASS GLOBE
6.75"/171.5mm
EXIT
Clear
Amber
Blue
Green
Red
9.25"/
235.0 mm
VPGL-2HR
VPGL-2AM
VPGL-2BL
VPGL-2GR
VPGL-2RE
KGU2
Globe Guard
Three-Way Exit Sign
CJEXRN
5.75"/146.1mm
DIA.
30° Angle
KR2-AN
5.69”/
144.5mm
* Standard and deep dome reflectors may interfere with bottom conduit entry if used with KPST and KPWB mounting hoods.
11.38"/
289.1mm
920
6.63”/
168.4mm
13.25"/336.6mm
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
KRG2
Refractor Guard
Mercmaster™ III Luminaires Family Tree
ing Mount
25° Stanchion Mount
KPC75
KPC100
KPS125
KPS150
90° Stanchion Mount
KPST125
KPST150
Wall Mount
KPWB75
KPWB100
Lighting
0"/
7mm
KPBR SERIES
50 W-150 W HPS
100 W, 175 W,
200 W, 250 W PSMH
Mogul Base
7.75"/
196.9mm
7.75"/
196.9mm
Metal Halide
100W Max
Lamp Extender
Standard Dome
CMR-4ST*
Standard Dome Deep Dome
CMR-4ST *
CMR-4DD *
30° Angle
CMR-4AN
OLYMERIC
FRACTORS
MA 2 LPRF-2CP
MA 3 LPRF-3CP
MA 4 LPRF-4CP
MA 5 LPRF-5CP
GLASS GLOBE
Clear VPGL-3HR
(for 100 W HPS only)
GLASS REFRACTORS
NEMA 1 LPG-R1
NEMA 3 LPG-R3
NEMA 5 LPG-R5
GLASS REFRACTORS
30° Angle
CMR-4AN
VPGL-2HR
VPGL-2AM
VPGL-2BL
VPGL-2GR
VPGL-2RE
NEMA 2 KPRF-400-2
NEMA 3 KPRF-400-5
Clear VPGL-4HR
KPBG-12
12” Wire Guard
KRG2
Refractor Guard
KRG2
Refractor Guard
16” Lens
Enclosed Reflector
KPR-4HB
GLASS GLOBE
30° Angle
KR2-AN
GLASS GLOBE
Clear
Amber
Blue
Green
Red
KPB400 SERIES
250 W-400 W HPS
250 W, 320 W, PSMH
350 W, 400 W PSMH
Mogul Base
GHB7000-NG
16” Wire Guard
KPGU400
Globe Guard
GU2
lobe Guard
* Standard and deep dome reflectors may interfere with bottom conduit entry if used with KPST and KPWB mounting hoods.
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
921
Lighting: Enclosed and Gasketed — Area — HID
KPB SERIES
50 W-150 W HPS
100 W, 175 W,
200 W, 250 W PSMH (KPBG)
Mogul Base
Mercmaster™ III Low Profile Luminaires
High Pressure Sodium and Pulse Start Metal Halide
Listed for simultaneous exposure to combustible dusts and flammable gases or vapors.
Class I, Division 2, Groups A, B, C, D
Class I, Zone 2, AEx nA nR IIC (Z2)
Class I, Zone 2, Ex nR IIC (Z) V
Class I, Zone 2, AEx nR IIC (ZB)
Class II, Division 1 and 2, Groups E, F, G
Class III
Simultaneous Exposure (Class I, Division 2/
Class II, Division 1)
Fixtures Outside Type (Salt Water)
Type 4X
IP66
Lighting: Enclosed and Gasketed — Area — HID
Lighting
Applications
• Enclosed and gasketed fixtures suitable for use in:
— Marine and wet locations
— A wide range of industrial, chemical processing and other
areas where flammable gases and vapors or combustible
dusts are present under conditions defined by the National
Electrical Code as Class I, Division 2; Class II, Division 1 and
2; and Class III
— Areas of low clearance, low ceiling heights or where fixture
weights must be minimized
— For Zone 2, the method of protection is AEx nA nR –
Restricted Breathing/Nonsparking or AEx nR – Restricted
Breathing
— Non-hazardous locations where severe weather conditions,
excessive moisture, dirt, dust, corrosive atmosphere or high
ambient temperatures are encountered
• Typical applications include:
— Pulp and paper mills
— Processing plants
— Chemical plants
— Oil refineries
— Foundries
— Manufacturing plants
— Storage areas
— Waste and sewage treatment
— Parking garages
— Other areas where dust, water, dirt and rough usage are a
problem
Features
• Compact light weight low profile design is suited for low
mounting heights in conjunction with lower wattage fixtures.
• Modular design allows scores of fixture component combinations
to meet installation and lighting needs. Uses same mounting
hoods and optical accessories as Mercmaster III.
• A choice of heat-resistant prismatic glass refractors (NEMA I, III
or V) or heat-resistant globes which thread directly into ballast
housing. Photometrics available upon request – contact your
local sales representative.
• Standard dome or 30° angle reflectors made of fiberglass
reinforced white polyester. Highly resistant to corrosive
atmospheres.
• Accommodates medium base lamps.
• A wide range of voltages available (120 to 600 Volt) and ballast
types (Reactor, CWA, CWI and Super CWA).
• Medium base lamp type and watts:
— HPS 50 W-150 W
— PSMH 50 W-175 W
• Hinge has high lip for added safety during installation
and servicing. Hinge and bolt construction assures 360º
compression at all points on ballast housing gasket for positive
sealing. Swing away design of captive bolt and nut simplifies
servicing.
• All Mercmaster III mounting hoods have provision for easy field
installation of fuses in fixtures (see fuse kits).
• Fixtures are for use in Class I, Zone 2 hazardous locations.
• The AEx nA nR / Ex nR (V) factory sealed Mercmaster III
prevents vapors and gases from entering the globe chamber.
There are no seals or putty required which will reduce
installation time and installation errors.
Low Profile Mercmaster III with Prismatic Globe and Guard
Standard Materials
• Mounting hoods, bodies and guard: cast copperfree
(4/10 of 1% max.) aluminum
• All hardware and catch assemblies: stainless steel
• Reflectors: Fiberglass reinforced white polyester
• Globes and Refractors: heat-resistant prismatic glass
Standard Finishes
• Mounting hoods, bodies and guards: baked gray epoxy-clad
finish, electrostatically applied for complete uniform protection
Options
• Quartz Auxiliary comes to full brightness immediately and
remains lit until the HID lamp attains 60-70% of full illumination.
Quartz Auxiliary supplied with relay switch and socket to accept
120 V quartz double-contact bayonet base lamp (not included).
Add suffix -E †.
• Guards with gray epoxy painted to match fixtures, supplied with
stainless steel screws. Add suffix -G before voltage suffix.
• Hot Restrike to restrike HPS lamp immediately when power is
restored after a momentary power interruption. Add suffix -R.
• Smart Starter incorporates a 1-1/2 minute timer and performs
as a conventional starter to normally start lamp. Removes
itself from circuit if lamp burns out or is removed from socket.
Eliminates starter failures caused by prolonged operation with
cycling or failing lamps and simplifies finding their location,
reducing maintenance and repair costs. Available for all fixtures.
Add suffix -S.
• Smart Hot Restrike will immediately restrike HPS lamp when
power is restored after a momentary power interruption. The
smart function removes the hot restrike ignitor from the circuit
if the lamp burns out or is removed from the socket. Eliminates
starter failures caused by prolonged operation with cycling or
failing lamps. Add suffix -SR.
• AEx nA nR fixtures, add suffix -Z2.
• AEx nR fixtures, add suffix -ZB.
• Ex nR fixtures, add suffix -Z V.
• Reflectors are available as standard dome and 30° angle
polyester. Order separately.
† Fixtures equipped with quartz auxiliary lamp do not comply with NEC/CEC V requirements and are not suitable for use in classified locations.
V CSA Certification Only.
922
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
Mercmaster™ III Low Profile Luminaires
High Pressure Sodium and Pulse Start Metal Halide
Listed for simultaneous exposure to combustible dusts and flammable gases or vapors.
Class I, Division 2, Groups A, B, C, D
Class I, Zone 2, AEx nA nR IIC (Z2)
Class I, Zone 2, Ex nR IIC (Z) V
Class I, Zone 2, AEx nR IIC (ZB)
Class II, Division 1 and 2, Groups E, F, G
Class III
Simultaneous Exposure (Class I, Division 2/
Class II, Division 1)
Certifications and Compliances *
Fixtures Outside Type (Salt Water)
Type 4X
IP66
Related Products
• Photocells for classified use are available, see PCD2 Series.
Lighting
• UL Listed: 60079-15
• UL Standard: 1598A, UL 844, Marine Type Electric Fixtures
Outside Type (Salt Water)
• CSA Certified: LR25428
Order using catalog numbering guide below or select catalog number from tables on following pages.
Catalog Numbering Guide
Series:
ML Mercmaster III
Low Profile
A
L
Lamp Type:
I - Incandescent
L - High Pressure
Sodium
H or P - Pulse Start
Metal Halide
H - 175 W Metal
Halide (available
with TT voltage
only) V
Mounting:
A - Pendant (rigid
mounting)
C - Ceiling
D - Pendant Cone Hood
F - Pendant (flexible
mounting)
R - 90° Stanchion
S - 25° Stanchion
W - Wall
15
2
G1
Hub Size:
2 - 3/4” NPT
3 - 1” NPT
4 - 1-1/4” NPT
stanchion
5 - 1-1/2” NPT
stanchion
Wattage:
10 - 100 W HPS, PSMH
15 - 150 W HPS, PSMH
and 60-150 W max.
Incandescent
17 - 175 W PSMH
17 - 175 W MH V
50 - 50 W HPS, PSMH
70 - 70 W HPS, PSMH
G
MT
R
Z2
Guard Options:
G - Cast Guard
N - No Guard
Optical Assembly: ➋
G1 - Globe
J1 - NEMA I Glass
Refractor
J3 - NEMA III Glass
Refractor
J5 - NEMA V Glass
Refractor
P2 - NEMA II Polymeric
Refractor
P3 - NEMA III Polymeric
Refractor
P4 - NEMA IV Polymeric
Refractor
P5 - NEMA V Polymeric
Refractor
Options:
E - Emergency Quartz ➎
F - Fuse Kit (Specify
Voltage) ➏
R - Hot Restrike ➌
S - Smart Starter ➍
SR - Smart Hot
Restrike ➌
H1 - Photocontrol 120 V
H2 - Photocontrol 208 V
H3 - Photocontrol 240 V
H4 - Photocontrol 277 V
C - Safety Cable
Adapted V
D - E-27 Export Socket
T - Terminal Blocks V
V - Anti-Vibration
Modifications V
X - Appledapter ➐
Mounting Hood
Adapter V
Suffix:
Voltage: ➊
LB - Incandescent, 120,
Z2 - Zone 2 suffix
60 Hz
(required for
MT - 120/208/240/277,
AEx nA nR
60 Hz
rating)
5MT - 120/208/240/
ZB - Zone 2 suffix
277/480, 60 Hz
(required for
48 - 480, 60 Hz
AEx nR)
125 - 120, 50 Hz
Z - Zone 2 suffix
225 - 225, 50 Hz
226 - 220, 60 Hz
(required for
245 - 240, 50 Hz
Ex nR) V
C2 - 208, 60 Hz, CWI V
C3 - 240, 60 Hz, CWI V
C6 - 480, 60 Hz, CWI V
C7 - 600, 60 Hz, CWI V
TT - 120/277/347, 60 Hz,
CWA V
* Compliance data varies for specific fixtures. Consult Appleton regarding suitability of specific fixtures for a particular application.
➊ Other voltages, frequencies available – contact your local sales representative. Voltages shown are limited to specific combinations; refer to following pages.
➋ Polymeric Refractor suitable for Class II, Groups F and G, NEMA 4X and Marine Type Electric Fixtures Outside Type (Salt Water) only (100 W PSMH Max.).
Reflectors ordered separately.
➌ Available for 50-150 W HPS fixtures only.
➍ Available for HPS or PSMH fixtures.
➎ Not suitable for hazardous location per NEC/CEC V.
➏ Canadian Electrical Code does NOT allow fusing in hazardous locations V.
➐ Appledapter is available for use with the pendant, ceiling and angled stanchion mounting only.
V CSA Certification Only.
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
923
Lighting: Enclosed and Gasketed — Area — HID
ML
Mercmaster™ III Low Profile Luminaires
High Pressure Sodium and Pulse Start Metal Halide
Listed for simultaneous exposure to combustible dusts and flammable gases or vapors.
Class I, Division 2, Groups A, B, C, D
Class I, Zone 2, AEx nA nR IIC (Z2)
Class I, Zone 2, Ex nR IIC (Z) V
Class I, Zone 2, AEx nR IIC (ZB)
Class II, Division 1 and 2, Groups E, F, G
Class III
Simultaneous Exposure (Class I, Division 2/
Class II, Division 1)
Fixtures Outside Type (Salt Water)
Type 4X
IP66
Lighting: Enclosed and Gasketed — Area — HID
Lighting
Illustrated Features
Vented Reflectors
Reflectors are thick, tough fiberglass-
reinforced white polyester, vented for
cooler operation. Quickly attach with
furnished stainless steel screws.
High Temperature Sockets
Medium base high-temperature porcelain
sockets.
Aluminum Inner Reflector
Solid aluminum inner reflector (for
refractor ballast housings only) improves
photometric efficiency.
Globe Chamber
Completely sealed from the ballast
housing and outside vapors/air (nR).
Electrical Protection
Ground wire provided to bond mounting
hood to ballast housing.
Fuses
Two screws secure fuse kit to mounting
boss in any Mercmaster mounting hood.
Fuse included.
Photocell
Available for all fixtures except cone and
ceiling mount. Installs through knock-out
in mounting hood. Provides continuous
ON-OFF dusk-to-dawn control.
Stainless Steel Inserts
Ballast bodies have stainless steel
threaded inserts to receive stainless steel
screws for reflectors and guard. Prevents
"freezing”, allowing guards and reflectors
to be easily removed and replaced at any
time, without damage to the housing.
Epoxy Finish
Ballast housing, hoods and guards are
copperfree aluminum with epoxy powder
coat finish.
Prismatic Glass Globes and Refractors
Heat-resistant globes and refractors
thread directly into ballast housing and
seal against a high-temperature
silicone rubber gasket.
Ballast Assembly
Utilizing non-sparking components
avoiding the ignition of gases or vapors
that may be present (nA).
Mounting Hood and Globe Gaskets
Silicone rubber gaskets seals out
moisture, dirt and dust. Stays flexible,
withstands high temperatures. Closure
design assures uniform gasket
compression.
Terminal Blocks (Zone 2)
A seven-point terminal block is provided
to facilitate wiring. Terminal block
accommodates wire size ranging from #8
to #24 AWG.
Cooler Operating Cone Hood
Larger sloped surface sheds dusts, dirt
and combustible fibers providing better
heat dissipation.
"Safety" High
Hinge
Extra-high hinge
provides additional
protection against
accidental
ballast housing
disengagement
during installation or
maintenance.
Stainless Steel
Latch Assembly
Captive, stainless
steel latch
assembly bolt
and nut closes
securely, resists
attack of corrosive
atmospheres.
Swing-away design
simplifies servicing.
V CSA Certification Only.
924
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
Mercmaster™ III Low Profile Luminaire Thermal Performance
Class I, Division 2; Class II, Division 1; Simultaneous exposure to hazardous conditions in both classifications
Temperature identification numbers of Mercmaster III Low Profile High Pressure Sodium and Pulse Start Metal Halide
Class I, Division 2, Groups A, B, C, D
Class I, Zone 2, AEx nA nR IIC (Z2)
Class I, Zone 2, Ex nR IIC (Z) V
Class I, Zone 2, AEx nR IIC (ZB)
Lamp
50
70
HPS
HPS
HPS
Class II, Division 1
Groups E, F and G
Simultaneous Exposure
Class I, Division 2 / Class II, Division 1
Supply
Wire
Temp.
(°F/°C)
Ambient
Temp.
(°F/°C)
Globe
Globe &
Reflector
Refractor
Globe
Globe &
Reflector
Refractor
Globe
Globe &
Reflector
194/90
104/40
T3
T3
T3B
T4A
T4A
T5
T3
T3
T3
194/90
131/55
T3
T3
T3A
T4A
T4A
T4A
T2D
T2D
T2D
194/90
149/65
T3
T3
T3A
T4
T4
T4A
T2C
T2C
T2C
194/90
104/40
T3
T3
T3
T4
T4
T5
T2B
T2B
T2D
194/90
131/55
T2D
T2D
T3
T3C
T3C
T4A
T2B
T2B
T2C
Class I, Division 2
Refractor
194/90
149/65
—
—
T3
—
—
T4
—
—
T2B
194/90
104/40
T2C
T2C
T2D
T4
T4
T4A
T2B
T2B
T2B
194/90
131/55
T2B
T2B
T2C
T3C
T3C
T4
T2A
T2A
T2A
194/90
149/65
—
—
—
—
—
—
—
—
—
104/40
T2A
T2A
T2B
T3A *
—
T4
325
—
T2
150
HPS
194/90
194/90
104/40
T3
T3
T3A
T4A
T4A
T6
T2D
T2D
T3
50
PSMH
194/90
131/55
T3
T3
T3
T4
T4
T5
T2C
T2C
T2D
70
PSMH
194/90
149/65
T3
T3
T3
T4
T4
T4A
T2B
T2B
T2D
194/90
104/40
T3
T3
T3
T3C
T3C
T4A
T2B
T2B
T2C
194/90
131/55
T2D
T2D
T3
T3C
T3C
T4A
T2A
T2A
T2B
230/110
149/65
—
—
T3
—
—
T4
—
—
T2B
194/90
104/40
T2A
T2A
T2B
T3B
T3B
T4A
T2
T2
T2A
100
PSMH
194/90
131/55
T2A
T2A
T2B
T3A *
T3A *
T4
T1
T1
T2
150
PSMH 230/110
104/40
350
350
325
—
—
T3B
—
—
T1
175
PSMH 230/110
104/40
350
350
325
—
—
T3B
—
—
T1
175
MH V
230/110
104/40
—
—
325
—
—
T3B
—
—
—
194/90
104/40
T3B
T3B
T3C
—
—
—
—
—
—
194/90
131/55
T3A
T3A
T3C
—
—
—
—
—
—
194/90
149/65
T3A
T3A
T3C
—
—
—
—
—
—
194/90
104/40
T3
T3
T3
—
—
—
—
—
—
194/90
131/55
T3
T3
T3
—
—
—
—
—
—
194/90
149/65
T2D
T2D
T3
—
—
—
—
—
—
60
100
150
Inc.
Inc.
Inc.
194/90
104/40
T2D
T2D
T3
—
—
—
—
—
—
194/90
131/55
T2B
T2B
T2D
—
—
—
—
—
—
194/90
149/65
T2B
T2B
T2D
—
—
—
—
—
—
“T” Numbers Represent the Maximum Lamp Temperature for Class I, Division 2 Locations and
Maximum Surface Temperature Under Dust Blanket for Class II, Division 1 Locations.
“T” #
T1
350
325
T2
T2A
T2B
T2C
T2D
T3
T3A
T3B
T3C
T4
T4A
T5
T6
Temp.
Range
(˚ºF)
664842
619662
574617
538572
502536
448500
421446
394419
358392
331356
322329
277320
250275
214248
187212
185
Temp.
Range
(°C)
351450
326350
301325
281300
261280
231260
216230
201215
181200
166180
161165
136160
121135
101120
86100
85
* “T” numbers are for Groups E and F only.
V CSA Certification only.
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
925
Lighting: Enclosed and Gasketed — Area — HID
100
Type
Fixtures Outside Type (Salt Water)
Type 4X
IP66
Lighting
Watts
Class II, Division 1 and 2, Groups E, F, G
Class III
Simultaneous Exposure (Class I, Division 2/
Class II, Division 1)
Mercmaster™ III Low Profile Luminaire Thermal Performance
Class I, Zone 2, AEx nA nR IIC, AEx nR IIC IP66, NEMA 4X
Temperature identification numbers of Mercmaster III Zone 2 Low Profile High Pressure Sodium and Pulse Start Metal Halide.
Class I, Division 2, Groups A, B, C, D
Class I, Zone 2, AEx nA nR IIC (Z2)
Class I, Zone 2, Ex nR IIC (Z) V
Class I, Zone 2, AEx nR IIC (ZB)
Class II, Division 1 and 2, Groups E, F, G
Class III
Simultaneous Exposure (Class I, Division 2/
Class II, Division 1)
Lamp
Lighting
Watts
50
HPS
70
Lighting: Enclosed and Gasketed — Area — HID
Type
HPS
100
HPS
150
HPS
50
PSMH
70
PSMH
100
PSMH
Supply Wire
Temp. (°F/°C)
Ambient
Temp. (°F/°C)
194/90
104/40
Fixtures Outside Type (Salt Water)
Type 4X
IP66
Class I, Zone 2 AEx nA nR IIC / Ex nR IIC
Globe w/
Globe
Reflector
Refractor
T6
T6
T6
Class I, Zone 2 AEx nR IIC
Globe w/
Globe
Reflector
Refractor
T6
T6
T6
194/90
131/55
T5
T5
T5
T5
T5
T5
194/90
149/65
T4
T4
T5
T4
T4
T5
194/90
104/40
T5
T5
T5
T5
T5
T5
194/90
131/55
T4
T4
T4
T4
T4
T4
194/90
149/65
—
—
T4
—
—
T4
194/90
104/40
T4
T4
T4
T4
T4
T4
194/90
131/55
T4
T4
T4
T4
T4
T4
194/90
104/40
T4
T4
T4
T4
T4
T4
194/90
104/40
T5
T5
T6
T5
T5
T6
194/90
131/55
T5
T5
T6
T5
T5
T6
194/90
149/65
T4
T4
T5
T4
T4
T5
194/90
104/40
T5
T5
T6
T5
T5
T6
194/90
131/55
T4
T4
T6
T4
T4
T6
230/110
149/65
—
—
T4
—
—
T4
194/90
104/40
T4
T4
T6
T4
T4
T6
194/90
131/55
T4
T4
T4
T4
T4
T4
150
PSMH
221/105
104/40
T3
T3
T4
T3
T3
T4
175
PSMH
221/105
104/40
T3
T3
T4
T3
T3
T4
175
MH V
230/110
104/40
—
—
T3
—
—
—
“T” Numbers represent the maximum surface temperature for luminaries with AEx nA nR, Ex nR and AEx nR rating:
The “T” number is established by separately determining the maximum temperature of the globe surface and ballast compartment. The hotter of the two is taken
to determine the “T” number for the overall fixture.
“T” Number
T1
T2
T3
T4
T5
T6
Temp. Range (°F)
547-842
394-572
277-392
214-275
187-212
185
Temp. Range (°C)
301-450
201-300
136-200
101-135
86-100
85
V CSA Certification Only.
926
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
Mercmaster™ III Low Profile Luminaires
50 W – 150 W HPS
High Power Factor (min. P.F. 90%). Medium base lamps.
Class I, Division 2, Groups A, B, C, D
Class I, Zone 2, AEx nA nR IIC (Z2)
Class I, Zone 2, Ex nR IIC (Z) V
Class I, Zone 2, AEx nR IIC (ZB)
Class II, Division 1 and 2, Groups E, F, G
Class III
Simultaneous Exposure (Class I, Division 2/
Class II, Division 1)
Lamp Type
Lamp Watts
Hub Size
(Inches)
Fixtures Outside Type (Salt Water)
Type 4X
IP66
Catalog Numbers ➌➍➎➏
With Globe
With Type V 8” Refractor ➋
Pendant — One Hub, Rigid Mounting
HPS
70
HPS
100
HPS
150
3/4
MLAL502G1N
1
MLAL503G1N
MLAL502J5N
MLAL503J5N
3/4
MLAL702G1N
MLAL702J5N
1
MLAL703G1N
MLAL703J5N
3/4
MLAL102G1N
MLAL102J5N
1
MLAL103G1N
MLAL103J5N
3/4
MLAL152G1N ➐
MLAL152J5N ➐
1
MLAL153G1N ➐
MLAL153J5N ➐
3/4
MLDL502G1N
MLDL502J5N
1
MLDL503G1N
MLDL503J5N
3/4
MLDL702G1N
MLDL702J5N
Lighting: Enclosed and Gasketed — Area — HID
Shown with Globe and Optional Guard
50
Lighting
HPS
Pendant Cone — One Hub, Rigid Mounting
HPS
HPS
HPS
Shown with Refractor
HPS
50
70
100
150
1
MLDL703G1N
MLDL703J5N
3/4
MLDL102G1N
MLDL102J5N
1
MLDL103G1N
MLDL103J5N
3/4
MLDL152G1N ➐
MLDL152J5N ➐
1
MLDL153G1N ➐
MLDL153J5N ➐
3/4
MLCL502G1N
MLCL502J5N
1
MLCL503G1N
MLCL503J5N
3/4
MLCL702G1N
MLCL702J5N
Ceiling — Five Hubs, Four Close-up Plugs
HPS
HPS
HPS
Shown with Globe
HPS
50
70
100
150
1
MLCL703G1N
MLCL703J5N
3/4
MLCL102G1N
MLCL102J5N
MLCL103G1N
MLCL103J5N
3/4
MLCL152G1N ➐
MLCL152J5N ➐
1
MLCL153G1N ➐
MLCL153J5N ➐
1
➊ For Flexible Pendant Mount, change A to F in catalog number (except 50 W HPS).
➋ To order fixture with NEMA Type I or NEMA Type III refractor, change final digit 5 in catalog number to 1 or 3.
➌ For fixtures with guards, substitute a G for the N before adding voltage suffix. See following pages for accessory ordering information.
➍ Add the following voltage and frequency designation before Z2 suffix:
Voltage Suffixes
Lamp Type Lamp Watts
LB
MT
5MT
48
125
225
226
235
245
C2 V
C3 V
C6 V
C7 V
TT V
Inc.
150 Max.
X
—
—
—
—
—
—
—
—
—
—
—
—
—
HPS
50
—
X
—
—
—
X
X
—
X
—
—
—
—
X
HPS
70
—
X
—
X
X
X
X
—
X
—
—
—
—
X
HPS
100
—
X
—
X
X
X
X
—
X
—
—
—
—
X
HPS
150
—
X
—
X
X
X
X
—
X
X
X
X
X
X
PSMH
50
—
X
—
X
—
—
—
—
—
—
—
—
—
X
PSMH
70
—
X
—
X
X
X
—
—
X
—
—
—
—
X
PSMH
100
—
X
—
X
X
X
—
—
X
—
—
—
—
X
PSMH
150
—
X
—
X
—
—
—
—
X
—
—
—
—
X
PSMH
175
—
X
X
X
—
—
—
—
X
—
—
—
—
X
175
—
X
—
—
—
—
—
—
—
X
X
X
X
X
MH V
Voltages:
LB - Incandescent, 120 V 60 Hz
125 - 120 V 50 Hz
245 - 240 V 50 Hz
MT - 120/208/240/277 V 60 Hz
225 - 225 V 50 Hz
C2 - 208 V 60 Hz, CWI V
226 - 220 V 60 Hz
C3 - 240 V 60 Hz, CWI V
C7 - 600 V 60 Hz, CWI V,
5MT - 120/208/240/277/480 V 60 Hz
48 - 480 V 60 Hz
235 - 230 V 50 Hz
C6 - 480 V 60 Hz, CWI V
TT - 120/277/347 V 60 Hz, CWA V
➎ Add Z2 suffix for factory sealed non-sparking/restricted breathing protection (AEx nA nR). Add ZB suffix for restricted breathing protection (AEx nR).
➏ Add Z for factory sealed restricted breathing protection (Ex nR) V.
➐ For 150 W HPS fixtures, use S-55 lamp type only.
V CSA Certification Only.
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
927
Mercmaster™ III Low Profile Luminaires
50 W – 150 W HPS
High Power Factor (min. P.F. 90%). Medium base lamps.
Class I, Division 2, Groups A, B, C, D
Class I, Zone 2, AEx nA nR IIC (Z2)
Class I, Zone 2, Ex nR IIC (Z) V
Class I, Zone 2, AEx nR IIC (ZB)
Class II, Division 1 and 2, Groups E, F, G
Class III
Simultaneous Exposure (Class I, Division 2/
Class II, Division 1)
Lighting: Enclosed and Gasketed — Area — HID
Lighting
Lamp Type
Wall — Five Hubs, Four Close-Up Plugs
Shown with Refractor and Optional Guard
Lamp Watts
HPS
50
HPS
70
HPS
100
HPS
150
HPS
50
Hub Size
(Inches)
Fixtures Outside Type (Salt Water)
Type 4X
IP66
Catalog Numbers ➌➍➎➏
With Globe
With Type V 8” Refractor ➋
3/4
MLWL502G1N
MLWL502J5N
1
MLWL503G1N
MLWL503J5N
3/4
MLWL702G1N
MLWL702J5N
1
MLWL703G1N
MLWL703J5N
3/4
MLWL102G1N
MLWL102J5N
1
MLWL103G1N
MLWL103J5N
3/4
MLWL152G1N ➐
MLWL152J5N ➐
1
MLWL153G1N ➐
MLWL153J5N ➐
1-1/4
MLSL504G1N
MLSL504J5N
1-1/2
MLSL505G1N
MLSL505J5N
1-1/4
MLSL704G1N
MLSL704J5N
25° Stanchion —
One Hub
HPS
HPS
Shown with Globe and Optional Guard
90° Stanchion —
One Hub
100
HPS
150
HPS
50
HPS
HPS
Shown with Refractor and Optional Guard
70
HPS
70
100
150
1-1/2
MLSL705G1N
MLSL705J5N
1-1/4
MLSL104G1N
MLSL104J5N
1-1/2
MLSL105G1N
MLSL105J5N
1-1/4
MLSL154G1N ➐
MLSL154J5N ➐
1-1/2
MLSL155G1N ➐
MLSL155J5N ➐
1-1/4
MLRL504G1N
MLRL504J5N
1-1/2
MLRL505G1N
MLRL505J5N
1-1/4
MLRL704G1N
MLRL704J5N
1-1/2
MLRL705G1N
MLRL705J5N
1-1/4
MLRL104G1N
MLRL104J5N
1-1/2
MLRL105G1N
MLRL105J5N
1-1/4
MLRL154G1N ➐
MLRL154J5N ➐
1-1/2
MLRL155G1N ➐
MLRL155J5N ➐
➊ For Flexible Pendant Mount, change A to F in catalog number (except 50 W HPS).
➋ To order fixture with NEMA Type I or NEMA Type III refractor, change final digit 5 in catalog number to 1 or 3.
➌ For fixtures with guards, substitute a G for the N before adding voltage suffix. See following pages for accessory ordering information.
➍ Add the following voltage and frequency designation before Z2 suffix:
Voltage Suffixes
Lamp Type Lamp Watts
LB
MT
5MT
48
125
225
226
235
245
C2 V
C3 V
C6 V
C7 V
TT V
Inc.
150 Max.
X
—
—
—
—
—
—
—
—
—
—
—
—
—
HPS
50
—
X
—
—
—
X
X
—
X
—
—
—
—
X
HPS
70
—
X
—
X
X
X
X
—
X
—
—
—
—
X
HPS
100
—
X
—
X
X
X
X
—
X
—
—
—
—
X
HPS
150
—
X
—
X
X
X
X
—
X
X
X
X
X
X
PSMH
50
—
X
—
X
—
—
—
—
—
—
—
—
—
X
PSMH
70
—
X
—
X
X
X
—
—
X
—
—
—
—
X
PSMH
100
—
X
—
X
X
X
—
—
X
—
—
—
—
X
PSMH
150
—
X
—
X
—
—
—
—
X
—
—
—
—
X
PSMH
175
—
X
X
X
—
—
—
—
X
—
—
—
—
X
175
—
X
—
—
—
—
—
—
—
X
X
X
X
X
MH V
Voltages:
LB - Incandescent, 120 V 60 Hz
125 - 120 V 50 Hz
245 - 240 V 50 Hz
MT - 120/208/240/277 V 60 Hz
225 - 225 V 50 Hz
C2 - 208 V 60 Hz, CWI V
226 - 220 V 60 Hz
C3 - 240 V 60 Hz, CWI V
C7 - 600 V 60 Hz, CWI V,
5MT - 120/208/240/277/480 V 60 Hz
48 - 480 V 60 Hz
235 - 230 V 50 Hz
C6 - 480 V 60 Hz, CWI V
TT - 120/277/347 V 60 Hz, CWA V
➎ Add Z2 suffix for factory sealed non-sparking/restricted breathing protection (AEx nA nR). Add ZB suffix for restricted breathing protection (AEx nR).
➏ Add Z for factory sealed restricted breathing protection (Ex nR) V.
➐ For 150 W HPS fixtures, use S-55 lamp type only.
V CSA Certification Only.
928
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
Mercmaster™ III Low Profile Luminaires
50 W - 175 W PSMH
High Power Factor (min. P.F. 90%). Medium base lamps.
Class I, Division 2, Groups A, B, C, D
Class I, Zone 2, AEx nA nR IIC (Z2)
Class I, Zone 2, Ex nR IIC (Z) V
Class I, Zone 2, AEx nR IIC (ZB)
Class II, Division 1 and 2, Groups E, F, G
Class III
Simultaneous Exposure (Class I, Division 2/
Class II, Division 1)
Lamp Type
Lamp Watts
Hub Size
(Inches)
Fixtures Outside Type (Salt Water)
Type 4X
IP66
Catalog Numbers ➌➍➎➏
With Globe
With Type V 8” Refractor ➋
Pendant — One Hub, Rigid Mounting
PSMH
70
PSMH
100
PSMH
150
PSMH
175
3/4
1
3/4
1
3/4
1
3/4
1
3/4
1
MLAH502G1N
MLAH503G1N
MLAH702G1N
MLAH703G1N
MLAH102G1N
MLAH103G1N
MLAP152G1N
MLAP153G1N
MLAP172G1N
MLAP173G1N
MLAH502J5N
MLAH503J5N
MLAH702J5N
MLAH703J5N
MLAH102J5N
MLAH103J5N
MLAP152J5N
MLAP153J5N
MLAP172J5N
MLAP173J5N
3/4
1
3/4
1
3/4
1
3/4
1
3/4
1
MLDH502G1N
MLDH503G1N
MLDH702G1N
MLDH703G1N
MLDH102G1N
MLDH103G1N
MLDP152G1N
MLDP153G1N
MLDP172G1N
MLDP173G1N
MLDH502J5N
MLDH503J5N
MLDH702J5N
MLDH703J5N
MLDH102J5N
MLDH103J5N
MLDP152J5N
MLDP153J5N
MLDP172J5N
MLDP173J5N
3/4
1
3/4
1
3/4
1
3/4
1
3/4
1
MLCH502G1N
MLCH503G1N
MLCH702G1N
MLCH703G1N
MLCH102G1N
MLCH103G1N
MLCP152G1N
MLCP153G1N
MLCP172G1N
MLCP173G1N
MLCH502J5N
MLCH503J5N
MLCH702J5N
MLCH703J5N
MLCH102J5N
MLCH103J5N
MLCP152J5N
MLCP153J5N
MLCP172J5N
MLCP173J5N
Lighting: Enclosed and Gasketed — Area — HID
50
Lighting
Shown with Globe and Optional Guard
PSMH
Pendant Cone — One Hub, Rigid Mounting
PSMH
50
PSMH
70
PSMH
100
PSMH
150
PSMH
Shown with Refractor
Ceiling — Five Hubs, Four Close-up Plugs
175
PSMH
50
PSMH
70
PSMH
100
PSMH
150
PSMH
175
Shown with Globe
➊ For Flexible Pendant Mount, change A to F in catalog number (except 50 W HPS).
➋ To order fixture with NEMA Type I or NEMA Type III refractor, change final digit 5 in catalog number to 1 or 3.
➌ For fixtures with guards, substitute a G for the N before adding voltage suffix. See following pages for accessory ordering information.
➍ Add the following voltage and frequency designation before Z2 suffix:
Voltage Suffixes
Lamp Type Lamp Watts
LB
MT
5MT
48
125
225
226
235
245
C2 V
C3 V
C6 V
C7 V
TT V
Inc.
150 Max.
X
—
—
—
—
—
—
—
—
—
—
—
—
—
HPS
50
—
X
—
—
—
X
X
—
X
—
—
—
—
X
HPS
70
—
X
—
X
X
X
X
—
X
—
—
—
—
X
HPS
100
—
X
—
X
X
X
X
—
X
—
—
—
—
X
HPS
150
—
X
—
X
X
X
X
—
X
X
X
X
X
X
PSMH
50
—
X
—
X
—
—
—
—
—
—
—
—
—
X
PSMH
70
—
X
—
X
X
X
—
—
X
—
—
—
—
X
PSMH
100
—
X
—
X
X
X
—
—
X
—
—
—
—
X
PSMH
150
—
X
—
X
—
—
—
—
X
—
—
—
—
X
PSMH
175
—
X
X
X
—
—
—
—
X
—
—
—
—
X
175
—
X
—
—
—
—
—
—
—
X
X
X
X
X
MH V
Voltages:
LB - Incandescent, 120 V 60 Hz
125 - 120 V 50 Hz
245 - 240 V 50 Hz
MT - 120/208/240/277 V 60 Hz
225 - 225 V 50 Hz
C2 - 208 V 60 Hz, CWI V
226 - 220 V 60 Hz
C3 - 240 V 60 Hz, CWI V
C7 - 600 V 60 Hz, CWI V,
5MT - 120/208/240/277/480 V 60 Hz
48 - 480 V 60 Hz
235 - 230 V 50 Hz
C6 - 480 V 60 Hz, CWI V
TT - 120/277/347 V 60 Hz, CWA V
➎ Add Z2 suffix for factory sealed non-sparking/restricted breathing protection (AEx nA nR). Add ZB suffix for restricted breathing protection (AEx nR).
➏ Add Z for factory sealed restricted breathing protection (Ex nR) V.
➐ For 150 W HPS fixtures, use S-55 lamp type only.
V CSA Certification Only.
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
929
Mercmaster™ III Low Profile Luminaires
50 W - 175 W PSMH
High Power Factor (min. P.F. 90%). Medium base lamps.
Class I, Division 2, Groups A, B, C, D
Class I, Zone 2, AEx nA nR IIC (Z2)
Class I, Zone 2, Ex nR IIC (Z) V
Class I, Zone 2, AEx nR IIC (ZB)
Class II, Division 1 and 2, Groups E, F, G
Class III
Simultaneous Exposure (Class I, Division 2/
Class II, Division 1)
Lamp Type
Lamp Watts
Hub Size
(Inches)
Fixtures Outside Type (Salt Water)
Type 4X
IP66
Catalog Numbers ➌➍➎➏
With Globe
With Type V 8” Refractor ➋
Lighting: Enclosed and Gasketed — Area — HID
Lighting
Wall — Five Hubs, Four Close-Up Plugs
Shown with Refractor and Optional Guard
PSMH
50
PSMH
70
PSMH
100
PSMH
150
PSMH
175
PSMH
50
PSMH
70
PSMH
100
PSMH
150
PSMH
175
PSMH
50
PSMH
70
PSMH
100
PSMH
150
PSMH
175
3/4
1
3/4
1
3/4
1
3/4
1
3/4
1
MLWH502G1N
MLWH503G1N
MLWH702G1N
MLWH703G1N
MLWH102G1N
MLWH103G1N
MLWP152G1N
MLWP153G1N
MLWP172G1N
MLWP173G1N
MLWH502J5N
MLWH503J5N
MLWH702J5N
MLWH703J5N
MLWH102J5N
MLWH103J5N
MLWP152J5N
MLWP153J5N
MLWP172J5N
MLWP173J5N
1-1/4
1-1/2
1-1/4
1-1/2
1-1/4
1-1/2
1-1/4
1-1/2
1-1/4
1-1/2
MLSH504G1N
MLSH505G1N
MLSH704G1N
MLSH705G1N
MLSH104G1N
MLSH105G1N
MLSP154G1N
MLSP155G1N
MLSP174G1N
MLSP175G1N
MLSH504J5N
MLSH505J5N
MLSH704J5N
MLSH705J5N
MLSH104J5N
MLSH105J5N
MLSP154J5N
MLSP155J5N
MLSP174J5N
MLSP175J5N
1-1/4
1-1/2
1-1/4
1-1/2
1-1/4
1-1/2
1-1/4
1-1/2
1-1/4
1-1/2
MLRH504G1N
MLRH505G1N
MLRH704G1N
MLRH705G1N
MLRH104G1N
MLRH105G1N
MLRP154G1N
MLRP155G1N
MLRP174G1N
MLRP175G1N
MLRH504J5N
MLRH505J5N
MLRH704J5N
MLRH705J5N
MLRH104J5N
MLRH105J5N
MLRP154J5N
MLRP155J5N
MLRP174J5N
MLRP175J5N
25° Stanchion —
One Hub
Shown with Globe and Optional Guard
90° Stanchion —
One Hub
Shown with Refractor and Optional Guard
➊ For Flexible Pendant Mount, change A to F in catalog number (except 50 W HPS).
➋ To order fixture with NEMA Type I or NEMA Type III refractor, change final digit 5 in catalog number to 1 or 3.
➌ For fixtures with guards, substitute a G for the N before adding voltage suffix. See following pages for accessory ordering information.
➍ Add the following voltage and frequency designation before Z2 suffix:
Voltage Suffixes
Lamp Type Lamp Watts
LB
MT
5MT
48
125
225
226
235
245
C2 V
C3 V
C6 V
C7 V
TT V
Inc.
150 Max.
X
—
—
—
—
—
—
—
—
—
—
—
—
—
HPS
50
—
X
—
—
—
X
X
—
X
—
—
—
—
X
HPS
70
—
X
—
X
X
X
X
—
X
—
—
—
—
X
HPS
100
—
X
—
X
X
X
X
—
X
—
—
—
—
X
HPS
150
—
X
—
X
X
X
X
—
X
X
X
X
X
X
PSMH
50
—
X
—
X
—
—
—
—
—
—
—
—
—
X
PSMH
70
—
X
—
X
X
X
—
—
X
—
—
—
—
X
PSMH
100
—
X
—
X
X
X
—
—
X
—
—
—
—
X
PSMH
150
—
X
—
X
—
—
—
—
X
—
—
—
—
X
PSMH
175
—
X
X
X
—
—
—
—
X
—
—
—
—
X
175
—
X
—
—
—
—
—
—
—
X
X
X
X
X
MH V
Voltages:
LB - Incandescent, 120 V 60 Hz
125 - 120 V 50 Hz
245 - 240 V 50 Hz
MT - 120/208/240/277 V 60 Hz
225 - 225 V 50 Hz
C2 - 208 V 60 Hz, CWI V
226 - 220 V 60 Hz
C3 - 240 V 60 Hz, CWI V
C7 - 600 V 60 Hz, CWI V,
5MT - 120/208/240/277/480 V 60 Hz
48 - 480 V 60 Hz
235 - 230 V 50 Hz
C6 - 480 V 60 Hz, CWI V
TT - 120/277/347 V 60 Hz, CWA V
➎ Add Z2 suffix for factory sealed non-sparking/restricted breathing protection (AEx nA nR). Add ZB suffix for restricted breathing protection (AEx nR).
➏ Add Z for factory sealed restricted breathing protection (Ex nR) V.
➐ For 150 W HPS fixtures, use S-55 lamp type only.
V CSA Certification Only.
930
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
Mercmaster™ III Low Profile Luminaire Mounting Hoods
High Pressure Sodium and Pulse Start Metal Halide
Listed for simultaneous exposure to combustible dusts and flammable gases or vapors.
Mounting Hoods
Description
Hub Size (Inches)
Catalog Number
One Hub, Rigid Mounting
3/4
KPA-75
1
KPA-100
3/4
KPAF-75
1
KPAF-100
3/4
KPCH-75
1
KPCH-100
Lighting
Pendant
Pendant — Flexible
One Hub, Flexible Mounting
One Hub, Rigid or Flexible Mounting
Ceiling
Five Hubs, Four Close-Up Plugs
3/4
KPC-75
1
KPC-100
3/4
KPWB-75
1
KPWB-100
Wall
Five Hubs, Four Close-Up Plugs
25° Stanchion
One Hub
1-1/4
KPS-125
1-1/2
KPS-150
1-1/4
KPST-125
1-1/2
KPST-150
90° Stanchion
One Hub
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
931
Lighting: Enclosed and Gasketed — Area — HID
Pendant Cone
Mercmaster™ III Low Profile Luminaire Ballast Bodies
High Pressure Sodium and Pulse Start Metal Halide
Listed for simultaneous exposure to combustible dusts and flammable gases or vapors.
Lighting
Ballast Bodies
Ballast Body for Glass Refractor
Ballast Body for Glass Globe or Polymeric Refractor
Lighting: Enclosed and Gasketed — Area — HID
High Pressure Sodium
High Power Factor (Min. P.F. 90%)
Lamp
Type
Inc.
Lamp
Watts
Pulse Start Metal Halide
Super Constant Wattage Autotransformer (Min. P.F. 90%)
Catalog Number ➍➎
For Globe
150 Max. MLBG15I
For Refractor
Voltage Suffixes
LB
MT
5MT
48
125
225
226
235
245 C2 V C3 V C6 V C7 V TT V
MLBR15I
X
—
—
—
—
—
—
—
—
—
—
—
—
—
HPS
50
MLBG50L ➊➋
MLBR50L ➊➋
—
X
—
—
—
X
X
—
X
—
—
—
—
X
HPS
70
MLBG70L ➊➋
MLBR70L ➊➋
—
X
—
X
X
X
X
—
X
—
—
—
—
X
HPS
100
MLBG10L ➊➋
MLBR10L ➊➋
—
X
—
X
X
X
X
—
X
—
—
—
—
X
HPS
150
MLBG15L ➊➋
MLBR15L ➊➋
—
X
—
X
X
X
X
—
X
X
X
X
X
X
PSMH
50
MLBG50H ➋➌ MLBR50H ➋➌
—
X
—
X
—
—
—
—
—
—
—
—
—
X
PSMH
70
MLBG70H ➋➌ MLBR70H ➋➌
—
X
—
X
X
X
—
—
X
—
—
—
—
X
PSMH
100
MLBG10H ➋➌ MLBR10H ➋➌
—
X
—
X
X
X
—
—
X
—
—
—
—
X
PSMH
150
MLBG15P ➋➌ MLBR15P ➋➌
—
X
—
X
—
—
—
—
X
—
—
—
—
X
PSMH
175
MLBG17P ➋➌ MLBR17P ➋➌
—
X
X
X
—
—
—
—
X
—
—
—
—
X
MH V
175
MLBG17H ➋
—
X
—
—
—
—
—
—
—
X
X
X
X
X
Voltages:
LB - Incandescent, 120 V 60 Hz
MT - 120/208/240/277 V 60 Hz
5MT - 120/208/240/277/480 V 60 Hz
48 - 480 V 60 Hz
125 - 120 V 50 Hz
225 - 225 V 50 Hz
226 - 220 V 60 Hz
MLBR17H ➋
235 - 230 V 50 Hz
245 - 240 V 50 Hz
C2 - 208 V 60 Hz, CWI V
C3 - 240 V 60 Hz, CWI V
C6 - 480 V 60 Hz, CWI V
C7 - 600 V 60 Hz, CWI V,
TT - 120/277/347 V 60 Hz, CWA V
➊ After voltage suffix add: -S for Smart Starter, -SR for Smart Hot Restrike, -R for ballast body with Hot Restrike Ignitor.
➋ Add -E after voltage suffix for ballast body with provision for Quartz Emergency Light. Not suitable for hazardous locations.
➌ After voltage suffix add: -S for Smart Starter.
➍ Add Z2 suffix for factory sealed non-sparking/restricted breathing protection (AEx nA nR). Add ZB suffix for restricted breathing protection (AEx nR).
➎ Add Z for factory sealed restricted breathing protection (Ex nR) V.
V CSA Certification Only.
932
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
Mercmaster™ III Low Profile Luminaire Accessories and Replacement Parts
High Pressure Sodium and Pulse Start Metal Halide
Listed for simultaneous exposure to combustible dusts and flammable gases or vapors.
Description
Catalog Number
Prismatic Glass Globes — Heat-Resistant
VPGL-1HR
VPGL-1AM
Blue
VPGL-1BL
Green
VPGL-1GR
Red
VPGL-1RE
IES/NEMA Distribution Curves
Catalog Number
Glass Globe
Light Distribution
Closed Prismatic Glass Refractors — All Heat-Resistant
LPG-R1
NEMA Type III
LPG-R3
NEMA Type V
LPG-R5
Closed Prismatic Polymeric Refractors — For Use with PSMH Lamps
100 W max. 104 °F/40 °C max. ambient temperature. Suitable for Class II, Division 1 and 2, Groups F, G;
NEMA 4X, UL 1598A Marine Type Electric Fixtures Outside Type (Salt Water)
Polymeric Refractor
NEMA Type II
LPRF-2CP
NEMA Type III
LPRF-3CP
NEMA Type IV
LPRF-4CP
NEMA Type V
LPRF-5CP
Description
Catalog Number
White Polyester Reflectors — Furnished with stainless steel screws
For Globe Fixtures
For Glass Refractor Fixtures
Standard Dome
Guards
30° Angle
Standard Dome
KR2-ST
Deep Dome
KR2-DD ➊
30° Angle
KR2-AN
Standard Dome
CMR-4ST ➋
Deep Dome
CMR-4DD ➊
30° Angle
CMR-4AN
Globe Guard
Refractor Guard
KGU1
KRG2
Globe Gasket
Refractor Gasket
VPGL-GK
KRF-GK
Globe Guard
Refractor Guard
Replacement Globe Gaskets — Silicone Rubber
Globe Gaskets
➊ Dark Skies Compliant.
➋ Standard and deep dome reflectors may interfere with bottom conduit entry if used with KPST and KPWB mounting hoods.
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
933
Lighting: Enclosed and Gasketed — Area — HID
Glass Refractor
NEMA Type I
Lighting
Clear
Amber
Mercmaster™ III Low Profile Luminaire Electrical Specifications and Fuse Kits
High Pressure Sodium and Pulse Start Metal Halide
Listed for simultaneous exposure to combustible dusts and flammable gases or vapors.
Lighting: Enclosed and Gasketed — Area — HID
Lighting
Class I, Division 2, Groups A, B, C, D
Class I, Zone 2, AEx nA nR IIC (Z2)
Class I, Zone 2, Ex nR IIC (Z) V
Class I, Zone 2, AEx nR IIC (ZB)
Electrical Specifications
Line
Type of
Starting
Voltage
Ballast ➊
Amps
50 Watt High Pressure Sodium
120
HX-HPF
0.58
208
HX-HPF
0.35
240
HX-HPF
0.31
277
HX-HPF
0.25
HX-HPF
0.26
347 V
70 Watt High Pressure Sodium
120
HX-HPF
0.90
208
HX-HPF
0.50
240
HX-HPF
0.44
277
HX-HPF
0.35
HX-HPF
0.30
347 V
480
HX-HPF
0.21
100 Watt High Pressure Sodium
120
HX-HPF
1.30
208
HX-HPF
0.76
240
HX-HPF
0.66
277
HX-HPF
0.60
HX-HPF
0.45
347 V
480
HX-HPF
0.33
480
C.W.I.
0.17
600
C.W.I.
0.14
150 Watt High Pressure Sodium ➋
120
HX-HPF
2.00
208
HX-HPF
1.15
240
HX-HPF
1.00
277
HX-HPF
0.85
HX-HPF
0.52
347 V
480
HX-HPF
0.50
480
C.W.I.
0.25
600
C.W.I.
0.19
50 Watt Pulse Start Metal Halide
120
HX-HPF
0.87
208
HX-HPF
0.51
240
HX-HPF
0.47
277
HX-HPF
0.32
HX-HPF
0.15
347 V
70 Watt Pulse Start Metal Halide
120
HX-HPF
0.80
208
HX-HPF
0.50
240
HX-HPF
0.43
277
HX-HPF
0.39
HX-HPF
0.20
347 V
480
HX-HPF
0.26
100 Watt Pulse Start Metal Halide
120
HX-HPF
1.20
208
HX-HPF
0.70
240
HX-HPF
0.61
277
HX-HPF
0.55
HX-HPF
0.40
347 V
480
HX-HPF
0.30
Class II, Division 1 and 2, Groups E, F, G
Class III
Simultaneous Exposure (Class I, Division 2/
Class II, Division 1)
Fixtures Outside Type (Salt Water)
Type 4X
IP66
Electrical Specifications
Line
Type of
Starting
Voltage
Ballast ➊
Amps
150 Watt Pulse Start Metal Halide
120
HX-HPF
1.75
208
HX-HPF
1.30
240
HX-HPF
0.85
277
HX-HPF
0.77
Super C.W.A.
0.65
347 V
480
Super C.W.A.
0.45
175 Watt Pulse Start Metal Halide
120
Super C.W.A.
0.90
208
Super C.W.A.
0.50
240
Super C.W.A.
0.35
277
Super C.W.A.
0.30
Super C.W.A.
0.25
347 V
480
Super C.W.A.
0.25
175 Watt Metal Halide V
120
C.W.A.
1.30
208
C.W.A.
0.75
240
C.W.A.
0.65
277
C.W.A.
0.55
347
C.W.A.
0.50
480
C.W.I.
0.20
600
C.W.I.
0.16
Fuse Kit for Field Installation
Operating
Amps
Total
Watts
0.58
0.33
0.29
0.25
0.21
64
64
64
64
68
0.82
0.48
0.41
0.36
0.30
0.21
94
94
94
94
94
94
1.15
0.67
0.60
0.52
0.39
0.31
0.30
0.24
130
130
130
130
130
135
130
130
1.70
0.95
0.85
0.72
0.56
0.47
0.42
0.35
188
188
188
188
188
189
190
190
Lamp
Watts
0.62
0.40
0.35
0.32
0.20
67
67
67
67
67
70W
0.85
0.52
0.44
0.39
0.28
0.23
95
95
95
95
88
95
1.15
0.70
0.58
0.50
0.40
0.35
130
130
130
130
129
140
50W
100W
150W
175W
Volts
120
208
240
277
347 V
120
208
240
277
347 V
480
120
208
240
277
347 V
480
120
208
240
277
347 V
480
120
208
240
277
347 V
480
Fuse Quantity
Required
1
2
2
1
1
1
2
2
1
1
2
1
2
2
1
1
2
1
2
2
1
1
2
1
2
2
1
1
2
Operating
Amps
Total
Watts
1.60
1.00
0.80
0.70
0.55
0.42
188
188
188
188
185
185
1.78
1.08
0.89
0.76
0.65
0.50
199
199
199
199
208
213
1.80
1.04
0.90
0.80
0.65
0.45
0.37
210
210
210
210
210
215
215
Fuse Kit Catalog Number
HPS
PSMH
F5
F3
F3
F3
F3
F2
F2
F2
F1
F1
F5
F4
F3
F3
F3
F3
F2
F2
F1
F2
F2
F1
F8
F6
F5
F4
F5
F3
F3
F3
F1
F2
F3
F2
F10
F10
F5
F5
F5
F5
F5
F4
F2
F2
F3
F3
—
F5
—
F3
—
F3
—
F2
F2
F2
—
F2
➊ C.W.A. – Constant Wattage Autotransformer. HX-HPF – High Reactance High Power Factor Autotransformer. Super C.W.A. – Super Constant Wattage Autotransformer.
➋ 150 W HPS units equipped with ballasts to operate 55 V lamps only.
V CSA Certification Only.
934
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
Mercmaster™ III Low Profile Luminaire Dimensions and Weights
High Pressure Sodium and Pulse Start Metal Halide
Listed for simultaneous exposure to combustible dusts and flammable gases or vapors.
Pendant (Rigid or Flex)
12.06”/306.0 mm
Pendant Cone
1.17”/
30.0 mm
Ceiling
12.06”/306.0 mm
25º Stanchion
13.62”/346.0 mm
1.75”/
45.0 mm
12.06”/306.0 mm
2.00”/
51.0 mm
15.28”/
388.0 mm
Lighting
5.59”/
142.0 mm
9.25”/
235.0 mm
12.05”/
306.0 mm
Wall Mount
17.01”/
432.0 mm
10.94”/
278.0 mm
90º Stanchion
3.38”/
85.8 mm
17.23”/438.0 mm
(4) Mounting Holes
0.31”/8.0 mm
7.60”/
193.0 mm
9.79”/249.0 mm
12.05”/
306.0 mm
12.06”/306.0 mm
Globe or Polymeric Refractor Ballast
Housing
8" Glass Refractor Ballast Housing
Standard Polyester Reflector
30º Angle Polyester Reflector
Globe, Guard and Refractors
Refractor Body, Refractor and Guard
Polymeric Refractor
Deep Dome
Mercmaster III Low Profile Ballast and Accessory Weights ➊
Globe Housing Ballast (Wt. Lbs/Kg) Refractor Housing Ballast (Wt. Lbs/Kg)
Watts
HPS
PSMH
HPS
PSMH
Mounting
Hoods
Wt.
Lbs/Kg
Refractors, Globes,
Guards and Reflectors
Wt.
Lbs/Kg
50
7.25/3.3
7.00/3.2
7.75/3.5
7.50/3.4
Pendant
2.25/1.0
8” Glass Refractor
5.25/2.4
70
8.25/3.7
7.75/3.5
8.75/4.0
8.25/3.7
Pendant Cone
2.50/1.1
Glass Globe
3.75/1.7
100
9.75/4.4
9.25/4.2
10.25/4.6
9.75/4.4
Ceiling
3.00/1.4
Refractor Guard
1.00/0.5
150
10.75/4.9
10.75/4.9
11.25/5.1
11.25/5.1
Wall
4.00/1.8
Globe Guard
1.00/0.5
175
—
11.00/5.0
—
11.50/5.2
25° Stanchion
3.25/1.5
Standard Dome
2.50/1.1
90° Stanchion
3.75/1.7
Deep Dome
5.00/2.3
30° Angle
2.50/1.1
Polymeric Refractor
2.43/1.1
➊ Weights are approximate. Add 0.25 lbs/0.1 kg for Quartz option.
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
935
Lighting: Enclosed and Gasketed — Area — HID
4.06”/
103.0 mm
PCD2 Series Factory Sealed Hazardous Location Photocontrol
For use in Class I, Division 2, Groups A, B, C, D locations
Maintains Class I, Division 2 rating for Mercmaster III – Low Profile, Mercmaster III, and Mercmaster III – 400 Series Luminaires, Mercmaster LED
Class I, Division 2, Groups A, B, C, D
NEMA 4X
Lighting
Applications
Materials
• Encapsulated photocontrol provides automatic dusk-to-dawn
lighting control in Class I, Division 2 locations.
• Typical applications include walkways, security areas and any
other outdoor lighting application.
• For use with Mercmaster III – Low Profile, Mercmaster III, and
Mercmaster III – 400 Series Luminaires.
• For remote mounting in FS Boxes.
• Encapsulated with epoxy sealing compound
• FS: aluminum
Certifications and Compliances
• UL Standard: 1604 – Hazardous (Classified) Locations
• cULus Recognized
Lighting: Enclosed and Gasketed — Area — HID
Features
• Factory sealed design eliminates the need for an explosionproof
enclosure.
• Can be easily installed in the field.
• Solid state design for performance and reliability.
• Available for 120, 208, 240, or 277 volts.
• 50-400 W HID, incandescent or fluorescent, 50/60 Hz.
• 1000 V.A. Voltage/Ampere
• Minimum time delay: 15 seconds to eliminate nuisiance tripping.
• Provided with (3) 18AWG stranded leads 6”/152.4mm in length.
• Will fit through standard 1/2” knockout.
Factory-Installed Photocontrol
Dimensions
Add to fixture catalog after voltage; i.e.: KPWBL1075MTH1.
Mercmaster III wall mounting hood
with photocontrol installed shown
Voltage Range
Suffix Designation
120 V, 50/60 Hz
H1
208 V, 50/60 Hz
H2
240 V, 50/60 Hz
H3
277 V, 50/60 Hz
H4
1.13”
28.7
mm
1.13”
28.7 mm
Photocontrol in FS Cover for Use with FS/FD Box
Supplied with two stainless steel screws. For neoprene gasket, order catalog number FS-GKR-1N.
Voltage Range
Catalog Number
120V, 50/60 Hz
FSKA-PC120D2
208-277V, 50/60 Hz
FSKA-PC247D2
1.375”
34.9
mm
1.375”
34.9 mm
2.56”
65.0
mm
2.56”
65.0 mm
1.13”
28.7 mm
Photocontrol for Field Installation
Max. Current
Catalog Number
120 V, 50/60 Hz
Voltage Range
8.3 Amp
PC120D2
208-277 V, 50/60 Hz
3.5 Amp
34.9 mm
PC247D2
2.56”
65.0 mm
936
1.375”
0.69”
17.5 mm
1.19”
30.2 mm
1.94”
49.2 mm
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
Mercmaster™ III Low Profile Luminaire Photometric Data
150 W HPS
Listed for simultaneous exposure to combustible dusts and flammable gases or vapors.
* Photometric data is based on a fixture with
a 150-watt clear High Pressure Sodium lamp
(16,000 lumen).
Zone
Lumens
For candlepower values of fixtures with other
HPS lamps, use the following multipliers: for
a 100 W (9,500 lumen) HPS lamp – 0.594; for a
70 W (6,400 lumen) HPS lamp – 0.40; for a 50 W
(4,000 lumen) HPS lamp – 0.25. For candlepower
values of fixture with guard, multiply by – 0.95.
Total Luminaire Efficiency = 83%
REPORT NUMBER: ML15LG
Lamps: 150 W High Pressure Sodium with Globe only *
CIE Type – Semi-Direct
28.58
10-20
123.97
20-30
304.16
30-40
513.64
0-180
3.9
Coefficients of Utilization – Zonal Cavity Method
40-50
889.19
90-270
3.9
Effective Floor Cavity Reflectance 0.20
50-60
1299.53
Diagonal
3.7
60-70
1506.73
70-80
1706.16
80-90
1800.53
Lumens % Lamp % Fixture
1 77 71 66 61 72 66 61 57 57 53 49 48 45 42 40 37 35 31
90-100
1791.58
0-30
4563.72
2.9
3.4
2 68 59 51 45 63 55 48 42 46 41 36 39 34 31 32 28 25 21
100-110
1652.69
0-40
970.35
6.1
7.3
3 61 50 42 35 56 46 39 33 39 33 28 32 27 23 26 22 19 16
110-120
1311.22
0-60
3159.07
19.7
23.8
4 55 43 35 28 50 40 32 26 34 27 22 28 23 18 22 18 15 12
120-130
351.25
0-90
8172.49
51.1
61.5
5 50 38 29 23 46 35 27 21 29 23 18 24 19 15 19 15 12
9
130-140
5.14
90-120
4755.49
29.7
35.8
6 46 33 25 19 42 31 23 18 26 20 15 21 16 12 17 13 10
7
140-150
0.00
90-130
5106.74
31.9
38.4
7 42 30 22 16 38 27 20 15 23 17 13 19 14 10 15 11
8
6
150-160
0.00
90-150
5111.87
31.9
38.4
8 39 27 19 14 36 25 18 13 21 15 11 17 12
9 14 10
7
5
160-170
0.00
90-180
5111.87
31.9
38.5
9 36 24 17 12 33 22 16 11 19 13
9 16 11
8 13
9
6
4
170-180
0.00
0-180
13284.37
83.0
100.0
10 33 22 15 11 31 20 14 10 17 12
8 15 10
7 12
8
5
4
Lumens
% Ceiling Rcc
80
70
50
30
10
0
% Walls Rw 70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0
Zonal Lumen Summary
Zone
0 91 91 91 91 85 85 85 85 75 75 75 65 65 65 55 55 55 51
Total Luminaire Efficiency = 73.2%
REPORT NUMBER: ML15LST
Lamps: 150 W High Pressure Sodium with
Standard Dome Reflector *
CIE Type – Direct
0-10
219.96
10-20
683.41
20-30
1267.92
30-40
1613.68
0-180
1.64
Coefficients of Utilization – Zonal Cavity Method
40-50
1967.79
90-270
1.64
Effective Floor Cavity Reflectance 0.20
50-60
2333.86
Diagonal
1.88
60-70
2328.33
70-80
1118.52
80-90
174.91
Spacing
Criteria
Plane
% Ceiling Rcc
80
70
50
30
10
0
% Walls Rw 70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0
Zonal Lumen Summary
Zone
0 87 87 87 87 85 85 85 85 81 81 81 78 78 78 75 75 75 73
Lumens % Lamp % Fixture
1 79 75 71 68 77 73 70 67 70 67 65 67 65 63 64 62 61 59
90-100
1.23
0-30
2171.29
13.6
18.5
2 70 63 58 53 68 62 57 52 59 55 51 57 53 50 55 52 49 47
100-110
0.00
0-40
3784.97
23.7
32.3
3 63 54 48 42 61 53 47 42 51 46 41 49 44 40 47 43 40 38
110-120
0.00
0-60
8086.62
50.5
69.1
4 57 47 40 35 55 46 39 34 44 38 34 42 37 33 41 36 33 31
120-130
0.00
0-90
11708.37
73.2
100.0
5 52 41 34 29 50 41 34 29 39 33 28 37 32 28 36 31 28 26
130-140
0.00
90-120
1.23
0.0
0.0
6 48 37 30 24 46 36 29 24 35 29 24 33 28 24 32 27 24 22
140-150
0.00
90-130
1.23
0.0
0.0
7 44 33 26 21 42 32 26 21 31 25 21 30 25 21 29 24 20 19
150-160
0.00
90-150
1.23
0.0
0.0
8 41 30 23 18 39 29 23 18 28 22 18 27 22 18 26 22 18 16
160-170
0.00
90-180
1.23
0.0
0.0
9 38 27 21 16 37 27 20 16 26 20 16 25 20 16 24 19 16 14
170-180
0.00
0-180
11709.6
73.2
100.0
10 35 25 19 15 34 24 18 14 24 18 14 23 18 14 22 18 14 13
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
937
Lighting: Enclosed and Gasketed — Area — HID
Zone
Spacing
Criteria
Plane
Lighting
0-10
Mercmaster™ III Low Profile Luminaire Photometric Data
150 W HPS
Listed for simultaneous exposure to combustible dusts and flammable gases or vapors.
* Photometric data is based on a fixture with
a 150-watt clear High Pressure Sodium lamp
(16,000 lumen).
Lighting: Enclosed and Gasketed — Area — HID
Lighting
Zone
Lumens
For candlepower values of fixtures with other
HPS lamps, use the following multipliers: for
a 100 W (9,500 lumen) HPS lamp – 0.594; for a
70 W (6,400 lumen) HPS lamp – 0.40; for a 50 W
(4,000 lumen) HPS lamp – 0.25. For candlepower
values of fixture with guard, multiply by – 0.95.
Total Luminaire Efficiency = 68.4%
REPORT NUMBER: ML15LAN
Lamps: 150 W High Pressure Sodium with
30° Angle Dome Reflector *
CIE Type – Direct
0-10
168.01
10-20
536.92
20-30
972.38
30-40
1342.99
0-180
2.3
40-50
1625.08
90-270
2.0
50-60
1721.88
Diagonal
1.8
60-70
1586.98
70-80
1369.71
80-90
995.76
Lumens % Lamp % Fixture
1 70 66 62 58 68 64 60 57 60 57 54 57 54 52 54 52 50 48
90-100
461.94
0-30
1677.30
10.5
15.3
2 63 56 50 45 60 54 49 44 51 46 42 48 44 41 45 42 39 37
100-110
127.24
0-40
3020.29
18.9
27.6
3 56 48 41 36 54 46 40 35 44 38 34 41 37 33 39 35 32 30
110-120
27.54
0-60
6367.25
39.8
58.2
4 51 42 35 29 49 40 34 29 38 32 28 36 31 27 34 30 26 24
120-130
4.31
0-90
10319.70
64.5
94.3
5 47 37 30 24 45 36 29 24 34 28 23 32 27 23 30 26 22 20
130-140
2.68
90-120
616.71
3.9
5.6
6 43 33 26 21 41 32 25 20 30 24 20 28 23 19 27 22 19 17
140-150
0.00
90-130
621.02
3.9
5.7
7 39 29 23 18 38 28 22 18 27 21 17 26 21 17 24 20 16 15
150-160
0.00
90-150
623.70
3.9
5.7
8 37 26 20 16 35 26 20 15 24 19 15 23 18 15 22 18 14 13
160-170
0.00
90-180
623.70
3.9
5.7
9 34 24 18 14 33 23 18 14 22 17 13 21 17 13 20 16 13 11
170-180
0.00
0-180
10943.41
68.4
100.0
10 32 22 16 12 31 22 16 12 21 15 12 20 15 12 19 15 11 10
Zone
Lumens
Spacing
Criteria
Plane
Coefficients of Utilization – Zonal Cavity Method
Effective Floor Cavity Reflectance 0.20
% Ceiling Rcc
80
70
50
30
10
0
% Walls Rw 70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0
Zonal Lumen Summary
Zone
0 80 80 80 80 78 78 78 78 74 74 74 70 70 70 66 66 66 64
Total Luminaire Efficiency = 77.6%
REPORT NUMBER: ML15LJ5
Lamps: 150 W High Pressure Sodium with
8” Prismatic Glass Refracter – NEMA Type V *
CIE Type – Semi-Direct
0-10
16.51
10-20
135.03
20-30
274.24
30-40
463.44
0-180
2.22
40-50
1125.38
90-270
2.20
50-60
1688.89
Diagonal
3.50
60-70
3137.76
70-80
2421.27
80-90
1145.98
90-100
411.16
0-30
425.77
2.7
3.4
2 66 56 49 42 62 54 47 41 49 43 38 44 39 35 40 36 32 29
100-110
632.32
0-40
889.22
5.6
7.2
3 58 46 38 31 54 44 36 30 40 33 27 36 30 25 32 27 23 21
110-120
448.30
0-60
3703.50
23.1
29.8
4 51 39 30 23 48 37 29 22 33 26 21 30 24 19 27 22 17 15
120-130
293.08
0-90
10408.50
65.1
83.8
5 46 34 25 18 43 32 24 18 29 22 16 26 20 15 23 18 13 11
130-140
154.61
90-120
1491.78
9.3
12.0
6 42 29 21 15 40 28 20 14 25 18 13 22 16 12 20 15 11
8
140-150
59.30
90-130
1784.86
11.2
14.4
7 39 26 18 12 36 25 17 12 22 15 11 20 14 10 18 13
9
7
150-160
9.99
90-150
1998.77
12.5
14.4
8 36 23 15 10 33 22 15 10 20 13
9 18 12
8 16 11
7
5
160-170
0.49
90-180
2009.26
12.6
16.2
9 33 21 14
9 31 20 13
8 18 12
8 16 11
7 15 10
6
4
170-180
0.00
0-180
12417.76
77.6
100.0
10 31 19 12
8 29 18 12
7 17 11
7 15 10
6 13
5
4
938
Spacing
Criteria
Plane
Coefficients of Utilization – Zonal Cavity Method
Effective Floor Cavity Reflectance 0.20
% Ceiling Rcc
80
70
50
30
10
0
% Walls Rw 70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0
Zonal Lumen Summary
Zone
0 89 89 89 89 86 86 86 86 79 79 79 73 73 73 68 68 68 65
Lumens % Lamp % Fixture
1 76 70 65 60 72 67 62 58 61 57 54 56 53 50 51 48 46 43
9
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
Mercmaster™ III Low Profile Luminaire Photometric Data
100 W PSMH
Listed for simultaneous exposure to combustible dusts and flammable gases or vapors.
* Photometric data is based on a fixture with
a 100-watt clear Pulse Start Metal Halide lamp
(8,500 lumen).
Zone
Lumens
For candlepower values of fixtures with other
PSMH lamps, use the following multipliers:
for a 50 W (3400 lumen) PSMH lamp – 0.40; for
a 70 W (5600 lumen) PSMH lamp – 0.66; for a
150 W (10,500 lumen) PSMH lamp – 1.24; for
a 175 W (17,500 lumen) PSMH lamp – 2.06.
For candlepower values of fixture with guard,
multiply by – 0.95.
Total Luminaire Efficiency = 85.7%
REPORT NUMBER: ML10HG
Lamps: 100 W Pulse Start Metal Halide with Globe only *
CIE Type – Semi-Direct
93.55
20-30
201.68
30-40
291.92
0-180
3.20
40-50
523.42
90-270
3.20
50-60
637.38
Diagonal
3.08
60-70
732.34
70-80
845.58
80-90
874.42
90-100
870.80
Spacing
Criteria
Plane
Coefficients of Utilization – Zonal Cavity Method
Effective Floor Cavity Reflectance 0.20
% Ceiling Rcc
% Walls Rw
Zonal Lumen Summary
70
50
30
10
0
70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0
0 95 95 95 95 89 89 89 89 78 78 78 68 68 68 58 58 58 54
Lumens % Lamp % Fixture
1 81 74 69 64 75 69 64 60 60 56 52 51 48 45 43 40 38 34
0-30
316.42
4.1
4.7
2 71 62 54 48 66 57 50 45 49 43 39 41 37 33 34 31 28 24
100-110 809.33
0-40
608.33
7.8
9.1
3 64 52 44 37 59 49 41 35 41 35 30 35 30 26 29 25 21 18
110-120 643.44
0-60
1769.13
22.7
26.5
4 57 45 37 30 53 42 34 28 36 29 24 30 25 20 25 20 17 14
120-130 139.00
0-90
4221.46
54.1
63.2
5 52 40 31 25 48 37 29 23 31 25 20 26 21 17 21 17 14 11
130-140
0.71
90-120 2323.56
29.8
34.8
6 48 35 27 21 44 33 25 19 28 21 17 23 18 14 19 15 11 9
140-150
0.00
90-130 2462.56
31.6
36.8
7 44 31 23 17 40 29 22 16 25 19 14 21 16 12 17 13 10 7
150-160
0.00
90-150 2463.27
31.6
36.8
8 41 28 20 15 37 26 19 14 22 16 12 19 14 10 16 11 8
6
160-170
0.00
90-180 2463.27
31.6
36.8
9 38 26 18 13 35 24 17 12 20 15 11 17 12 9 14 10 7
5
170-180
0.00
0-180
85.7
100.0
Zone
Zone
80
6684.73
Lumens
Total Luminaire Efficiency = 75.8%
CIE Type – Direct
10 35 23 16 12 32 22 15 11 19 13 9 16 11 8 13 9
6
5
REPORT NUMBER: ML10HST
Lamps: 100 W Pulse Start Metal Halide with
Standard Dome Reflector *
0-10
116.29
10-20
371.61
20-30
692.88
30-40
821.73
0-180
1.70
40-50
1064.03
90-270
1.70
50-60
1154.58
Diagonal
1.84
60-70
1134.19
70-80
470.22
80-90
83.66
Lumens % Lamp % Fixture
1 82 78 74 71 80 76 73 70 73 70 68 70 68 66 67 65 64 62
90-100
0.82
0-30
1180.78
15.1
20.0
2 73 66 61 56 71 65 60 55 62 58 54 60 56 53 57 54 51 50
100-110
0.00
0-40
2002.50
25.7
33.9
3 66 57 50 45 64 56 50 45 54 48 44 51 47 43 49 46 42 40
110-120
0.00
0-60
4221.11
54.1
71.4
4 60 50 43 37 58 49 42 37 47 41 36 45 40 36 43 39 35 33
120-130
0.00
0-90
5909.17
75.8
100.0
5 54 44 36 31 53 43 36 31 41 35 30 40 34 30 38 33 30 28
130-140
0.00
90-120
0.82
0.0
0.0
6 50 39 32 26 48 38 31 26 37 31 26 35 30 26 34 29 25 24
140-150
0.00
90-130
0.82
0.0
0.0
7 46 35 28 23 45 34 27 23 33 27 22 32 26 22 31 26 22 20
150-160
0.00
90-150
0.82
0.0
0.0
8 43 32 25 20 41 31 24 20 30 24 20 29 24 20 28 23 19 18
160-170
0.00
90-180
0.82
0.0
0.0
9 40 29 22 18 38 28 22 18 27 22 17 27 21 17 36 21 17 16
170-180
0.00
0-180
5910.00
75.8
100.0
10 37 26 20 16 36 26 20 16 25 20 16 24 19 16 24 19 15 14
Spacing
Criteria
Plane
Coefficients of Utilization – Zonal Cavity Method
Effective Floor Cavity Reflectance 0.20
% Ceiling Rcc
% Walls Rw
Zonal Lumen Summary
Zone
80
70
50
30
10
0
70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0
0 90 90 90 90 88 88 88 88 84 84 84 81 81 81 77 77 77 76
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
939
Lighting: Enclosed and Gasketed — Area — HID
21.19
10-20
Lighting
0-10
Mercmaster™ III Low Profile Luminaire Photometric Data
100 W PSMH
Listed for simultaneous exposure to combustible dusts and flammable gases or vapors.
* Photometric data is based on a fixture with
a 100-watt clear Pulse Start Metal Halide lamp
(8,500 lumen).
Lighting: Enclosed and Gasketed — Area — HID
Lighting
Zone
Lumens
For candlepower values of fixtures with other
PSMH lamps, use the following multipliers:
for a 50 W (3400 lumen) PSMH lamp – 0.40; for
a 70 W (5600 lumen) PSMH lamp – 0.66; for a
150 W (10,500 lumen) PSMH lamp – 1.24; for
a 175 W (17,500 lumen) PSMH lamp – 2.06.
For candlepower values of fixture with guard,
multiply by – 0.95.
Total Luminaire Efficiency = 71.3%
REPORT NUMBER: ML10HAN
Lamps: 100 W Pulse Start Metal Halide with
30° Angle Dome Reflector *
CIE Type – Direct
0-10
91.83
10-20
301.65
20-30
543.23
30-40
703.02
0-180
2.08
40-50
877.11
90-270
2.06
50-60
850.33
Diagonal
1.76
60-70
7753.51
70-80
667.27
80-90
471.44
Lumens % Lamp % Fixture
1 74 69 65 62 71 67 64 60 63 60 58 60 57 55 57 55 53 51
90-100
200.90
0-30
936.72
12.0
16.8
2 66 59 53 48 64 57 51 47 54 49 45 51 47 43 48 45 42 40
100-110
62.89
0-40
1639.74
21.0
29.5
3 59 51 44 38 57 49 43 38 46 41 36 44 39 35 41 37 34 32
110-120
14.42
0-60
3367.18
43.2
60.6
4 54 44 37 31 52 43 36 31 40 35 30 38 33 29 36 32 28 27
120-130
1.07
0-90
5281.39
67.7
95.0
5 49 39 32 26 47 38 31 26 36 30 25 34 29 25 32 28 24 22
130-140
0.00
90-120
278.21
3.6
5.0
6 45 35 28 23 43 34 27 22 32 26 22 30 25 21 29 24 21 19
140-150
0.00
90-130
279.28
3.6
5.0
7 42 31 24 20 40 30 24 19 29 23 19 27 22 18 26 22 18 16
150-160
0.00
90-150
279.28
3.6
5.0
8 39 28 22 17 37 28 21 17 26 21 17 25 20 16 24 19 16 14
160-170
0.00
90-180
279.28
3.6
5.0
9 36 26 19 15 35 25 19 15 24 19 15 23 18 14 22 17 14 13
170-180
0.00
0-180
5560.68
71.3
100.0
10 34 24 18 14 32 23 17 13 22 17 13 21 16 13 20 16 13 11
Zone
Lumens
Spacing
Criteria
Plane
Coefficients of Utilization – Zonal Cavity Method
Effective Floor Cavity Reflectance 0.20
% Ceiling Rcc
% Walls Rw
Zonal Lumen Summary
Zone
80
70
50
30
10
0
70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0
0 84 84 84 84 82 82 82 82 77 77 77 73 73 73 69 69 69 68
Total Luminaire Efficiency = 76.6%
REPORT NUMBER: ML10HJ5
Lamps: 100 W Pulse Start Metal Halide with
8” Prismatic Glass Refracter – NEMA Type V *
CIE Type – Semi-Direct
0-10
9.17
10-20
75.43
20-30
154.76
30-40
266.34
0-180
2.06
Coefficients of Utilization – Zonal Cavity Method
40-50
632.54
90-270
2.20
Effective Floor Cavity Reflectance 0.20
50-60
1155.59
Diagonal
3.26
60-70
1665.76
70-80
693.73
80-90
449.28
Lumens % Lamp % Fixture
1 77 71 67 62 73 68 64 60 63 59 56 58 55 52 53 51 49 46
90-100
177.44
0-30
239.35
3.1
4.0
2 67 58 51 45 64 56 49 44 51 46 41 47 42 38 43 39 36 33
100-110 288.25
0-40
505.69
6.5
8.5
3 59 48 40 34 56 46 39 32 42 36 30 38 33 28 34 30 26 24
110-120 208.52
0-60
2293.81
29.4
38.4
4 52 41 32 26 49 39 31 25 35 28 23 32 26 21 29 24 20 18
120-130 128.19
0-90
5102.58
65.4
85.4
5 47 35 26 20 44 33 25 19 30 23 18 27 21 17 25 20 15 13
130-140
56.80
90-120
674.20
8.6
11.3
6 43 30 22 16 40 29 21 15 26 19 14 24 18 13 21 16 12 10
140-150
14.94
90-130
802.38
10.3
13.4
7 39 27 19 13 37 25 18 13 23 16 12 21 15 11 19 14 10
8
150-160
0.10
90-150
874.12
11.2
13.4
8 36 24 16 11 34 23 15 10 21 14 10 19 13
9 17 12
8
6
160-170
0.00
90-180
874.22
11.2
14.6
9 33 21 14
9 31 20 14
9 19 12
8 17 11
8 15 10
7
5
170-180
0.00
0-180
5976.80
76.6
100.0
10 31 19 12
8 29 19 12
8 17 11
7 15 10
6 14
6
4
940
Spacing
Criteria
Plane
% Ceiling Rcc
% Walls Rw
Zonal Lumen Summary
Zone
80
70
50
30
10
0
70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0
0 89 89 89 89 85 85 85 85 79 79 79 73 73 73 68 68 68 65
9
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
Mercmaster™ III HID 50-250 Watt Luminaires
High Pressure Sodium and Pulse Start Metal Halide
Listed for simultaneous exposure to combustible dusts and flammable gases or vapors.
Class I, Division 2, Groups A, B, C, D
Class I, Zone 2, AEx nA nR IIC (Z2)
Class I, Zone 2, Ex nR IIC (Z) V
Class I, Zone 2, AEx nR IIC (ZB)
Class II, Division 1 and 2, Groups E, F, G
Class III
Simultaneous Exposure (Class I, Division 2/
Class II, Division 1)
Fixtures Outside Type (Salt Water)
Type 4X
IP66
Applications
Lighting
Pendant Mount Fixture
with Prismatic Glass Refractor
Straight Stanchion-Mount Fixture
with Prismatic Glass Refractor and
Guard
Features
• Modular design allows scores of fixture component
combinations to meet installation and lighting needs. Many
most-used combinations are offered prewired and assembled,
complete with lamp, packaged in a single carton and ready to
install.
• Mogul lamp types and wattages:
HPS 50W-150W
PSMH 70W-250W
• Choice of heat-resistant prismatic glass refractors (NEMA
distributions I, III and V), or heat-resistant prismatic glass globes
for hazardous area fixtures. Colored and clear polycarbonate
globes and Tuff-skin® † coated glass globes are available but are
NOT approved for use in classified areas. Fixtures with these
globes do NOT comply with code requirements, and should be
used in non-classified areas only. Globes and refractors thread
directly into ballast housing.
• Mounting hoods include cone-shaped pendant hood, standard
pendant, flexible pendant, ceiling and wall pendants (tapped
for 3/4” or 1” NPT), 25° angle stanchion, and 90° (straight)
stanchion (both tapped for 1-1/4” or 1-1/2” NPT).
• Cone hood fixtures for pendant mounting shed dust, dirt and
combustible fibers. Cone hood inhibits build-up that “insulates”
fixture and slows heat transfer, and provides increased surface
area for more effective heat dissipation.
Pendant Cone Fixture with
Prismatic Glass Globe and Guard
Ceiling Mount Fixture
with Prismatic Glass Globe, Guard
and Polyester 30° Angle Reflector
• Reflector choice includes standard dome and 30º angle types,
both made of Fiberglass reinforced white polyester. Highly
resistant to unusually corrosive applications. Reflectors are
vented for cooler, dirt-free operation and maintained lumen
output. They secure to ballast housing with stainless steel
screws threading into stainless steel inserts.
• For high corrosion resistance, fixture housing, mounting hoods
and guards are copperfree cast aluminum with baked epoxy
finish, electrostatically applied for uniformity. All exposed
hardware is stainless steel.
• Hinge has high lip for added safety during installation
and servicing. Hinge and bolt construction assures 360º
compression at all points on ballast housing gasket for positive
sealing. Swing-away design of captive bolt and nut simplifies
servicing.
• Body gaskets and globe gaskets are high-temperature silicone
rubber.
• Capacitors are non-PCB type, thermally isolated from ballast.
† Tuff-skin is a registered trademark of Thomas Manufacturing Corp., Parkton, Maryland.
V CSA Certification Only.
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
941
Lighting: Enclosed and Gasketed — Area — HID
• Enclosed and gasketed fixtures suitable for use in:
— Marine and wet locations
— A wide range of industrial, chemical processing and other
areas where flammable gases and vapors or combustible
dusts are present under conditions defined by the National
Electrical Code as Class I, Division 2; Class II, Division 1 and
2; and Class III
— For Zone 2, the method of protection is AEx nA nR –
Restricted Breathing/Nonsparking or AEx nR – Restricted
Breathing
— Non-hazardous locations where severe weather conditions,
excessive moisture, dirt, dust, corrosive atmosphere or
high ambient temperatures are encountered. 18% cooler
operation allows use in ambient temperatures up to
149°F/65°C depending on fixture component combinations
• Typical applications include:
— Pulp and paper mills
— Processing plants
— Chemical plants
— Oil refineries
— Foundries
— Manufacturing plants
— Storage areas
— Marine applications
• Fixtures have NEMA 4X listing.
• Suitability includes listing for use where there may be
simultaneous exposure to combustible dusts and flammable
gases and vapors. See listing pages for compliance data on
specific fixture component combinations.
Mercmaster™ III HID 50-250 Watt Luminaires
High Pressure Sodium and Pulse Start Metal Halide
Listed for simultaneous exposure to combustible dusts and flammable gases or vapors.
Lighting: Enclosed and Gasketed — Area — HID
Lighting
Class I, Division 2, Groups A, B, C, D
Class I, Zone 2, AEx nA nR IIC (Z2)
Class I, Zone 2, Ex nR IIC (Z) V
Class I, Zone 2, AEx nR IIC (ZB)
Class II, Division 1 and 2, Groups E, F, G
Class III
Simultaneous Exposure (Class I, Division 2/
Class II, Division 1)
• Mogul base porcelain socket with nickel-plated contacts has
392 °C/ 200 °C welded leads, prewired to the ballast. Assures
trouble-free operation in installations where high ambient
temperatures are encountered.
• HPS ballasts are High Power Factor (min. P.F. 90%).
• A wide range of voltages available (120 to 600 Volt) and ballast
types (Reactor, CWA, CWI and Super CWA).
• All Mercmaster III mounting hoods have provision for easy field
installation of fuses in fixtures (see fuse kit listings in this catalog
section).
• For electrical protection, a ground wire is provided on each
Mercmaster to bond hood and ballast housing.
• The AEx nA nR / Ex nR (V) factory sealed Mercmaster III
prevents vapors and gases from entering the globe chamber.
There are no seals or putty required which will reduce
installation time and installation errors.
• The AEx nR Mercmaster III fixture requires all wiring entries to
be sealed.
Standard Materials
• Mounting hoods, ballast bodies and guards: copperfree cast
aluminum (less than 4/10 of 1%)
• Exposed hardware: stainless steel; latch assemblies have
stainless steel bolt and captive nut; reflectors and guards attach
with strainless steel screws threading into stainless steel inserts.
• Reflectors: Fiberglass reinforced white polyester
• Globes: heat-resistant prismatic glass
• Refractors: heat-resistant prismatic glass
Standard Finishes
• Mounting hoods, ballast bodies, guards: epoxy powder coat
finish, electrostatically applied for complete, uniform surface
protection
• Reflectors: white polyester finish
Fixtures Outside Type (Salt Water)
Type 4X
IP66
• Hot Restrike will restrike HPS lamp immediately when power is
restored after a momentary power interruption. Add suffix -R.
• Smart Hot Restrike will immediately restrike HPS lamp when
power is restored after a momentary power interruption. The
smart function removes the hot restrike ignitor from the circuit
if the lamp burns out or is removed from the socket. Eliminates
starter failures caused by prolonged operation with cycling or
failing lamps. Add suffix -SR.
• Smart Starter incorporates a 1-1/2-minute timer and performs
as a conventional starter to normally start lamp. Removes
itself from circuit if lamp burns out or is removed from socket.
Eliminates starter failures caused by prolonged operation with
cycling or failing lamps and simplifies finding their location,
reducing maintenance and repair costs. Available for all HPS
and PSMH fixtures. Add suffix -S.
• Optional photocell for all fixtures except cone and ceiling mount
provides automatic “on-off” control.
• Quartz Auxiliary comes to full brightness immediately and
remains lit until the HID lamp attains 60-70% of full illumination.
Quartz Auxiliary supplied with relay switch and socket to accept
120 V quartz double contact bayonet base lamp (not included).
Add suffix -E to fixture catalog number. ‡
Certifications and Compliances
• UL Standard: UL 1598, UL 1598A, UL 844, UL 60079-0, UL
60079-15
• UL Listed: E10444
Related Products
• Classified area photo controls are also available.
Options
• AEx nA nR fixtures are available with a Class I, Zone 2 rating.
Add suffix -Z2.
• AEx nR fixtures are available with a Class I, Zone 2 rating. Add
suffix -ZB.
• Ex nR fixtures, add suffix -Z V.
• Fuses can be field-installed on Mercmaster III fixtures. Kits
include fuse block, wire connectors and screws for attaching to
mounting hood. Fixtures with fuses do not comply with Marine
Type Electric Fixtures Outside Type (Salt Water) requirements
for marine listing. For fuse kits, see Electrical Specifications and
Fuse Kits page.
‡ Fixtures equipped with a quartz auxiliary lamp do not comply with UL requirements and are not suitable for use in classified locations.
V CSA Certification Only.
942
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
Mercmaster™ III HID 50-250 Watt Luminaires
High Pressure Sodium and Pulse Start Metal Halide
Listed for simultaneous exposure to combustible dusts and flammable gases or vapors.
Class I, Division 2, Groups A, B, C, D
Class I, Zone 2, AEx nA nR IIC (Z2)
Class I, Zone 2, Ex nR IIC (Z) V
Class I, Zone 2, AEx nR IIC (ZB)
Class II, Division 1 and 2, Groups E, F, G
Class III
Simultaneous Exposure (Class I, Division 2/
Class II, Division 1)
Fixtures Outside Type (Salt Water)
Type 4X
IP66
Illustrated Features
Lighting
High Temperature Sockets
Mogul base high-temperature porcelain
sockets.
Aluminum Inner Reflector
Solid aluminum inner reflector (for
refractor ballast housings only) improves
photometric efficiency.
Globe Chamber (Zone 2)
Completely sealed from the ballast
housing and outside vapors/air (nA nR).
"Safety" High
Hinge
Extra-high hinge
provides additional
protection against
accidental
ballast housing
disengagement
during installation
or maintenance.
Stainless Steel
Latch Assembly
Captive, stainless
steel latch assembly
bolt and nut closes
securely, resists
attack of corrosive
atmospheres.
Swing-away design
simplifies servicing.
Terminal Blocks (Zone 2)
A seven-point terminal block is provided
to facilitate wiring. Terminal block
accommodates wire size ranging from #8
to #24 AWG.
Stainless Steel Inserts
Ballast bodies have stainless steel
threaded inserts to receive stainless steel
screws for reflectors and guard. Prevents
"freezing”, allowing guards and reflectors
to be easily removed and replaced at any
time, without damage to the housing.
Ballast Assembly (Zone 2)
Utilizing non-sparking components
avoiding the ignition of gases or vapors
that may be present (nA).
Mounting Hood and Globe Gaskets
Silicone rubber gasket seals out moisture,
dirt and dust. Stays flexible, withstands
high temperatures. Closure design
assures uniform gasket compression.
Electrical Protection
Ground wire provided to bond mounting
hood to ballast housing.
Epoxy Finish
Ballast housing, hoods and guards are
copperfree aluminum with epoxy powder
coat finish.
Photocell
Available for all fixtures except cone and
ceiling mount. Installs through knock-out
in mounting hood. Provides continuous
ON-OFF dusk-to-dawn control.
Heat-Resistant Globes and Refractors
Prismatic glass globes and refractors are
heat-resistant. They thread directly into the
ballast housing and seal against a hightemperature silicone rubber gasket.
Cooler Operating Cone Hood
Larger sloped surface sheds dusts, dirt
and combustible fibers providing better
heat dissipation.
Fuses
Two screws secure fuse kit to mounting
boss in any Mercmaster mounting hood.
Fuse included.
V CSA Certification Only.
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
943
Lighting: Enclosed and Gasketed — Area — HID
Vented Reflectors
Reflectors are thick, tough fiberglass-
reinforced white polyester, vented for
cooler operation. Quickly attach with
furnished stainless steel screws.
Mercmaster™ III HID 50-250 Watt Emergency Luminaires Accessories and Options
High Pressure Sodium and Pulse Start Metal Halide
Listed for simultaneous exposure to combustible dusts and flammable gases or vapors.
Lighting
Class I, Division 2, Groups A, B, C, D
Class I, Zone 2, AEx nA nR IIC (Z2)
Class I, Zone 2, Ex nR IIC (Z) V
Class I, Zone 2, AEx nR IIC (ZB)
Fixtures Outside Type (Salt Water)
Type 4X
IP66
Quartz Emergency Light for Pulse Start Metal Halide or High Pressure Sodium Fixtures *
Mercmaster fixtures for or metal halide and high pressure sodium lamps can be supplied with a
socket to accept a 150 W or 250 W, 120 V quartz lamp. This D.C. bayonet base socket is in addition
to the standard lamp socket. In the event of a momentary power interruption, the quartz lamp is
automatically switched on. The single ended quartz lamp remains energized until the HID restrikes
and reaches about 60% output.
Quartz Emergency Light
Lighting: Enclosed and Gasketed — Area — HID
Class II, Division 1 and 2, Groups E, F, G
Class III
Simultaneous Exposure (Class I, Division 2/
Class II, Division 1)
The quartz emergency lamp socket is wired to a 120 V tap on the ballast and is therefore
independent of the lighting fixture voltage. No special field wiring is necessary.
Description
Catalog Suffix
For fixture volts of 120, 208, 240 or 277
-MTE
For fixture volts of 480
-48E
Quartz Emergency Light for
HPS
Fixtures
QuartzPSMH
Emergencyor
Light
for Pulse
Start Metal Halide or
High Pressure Sodium Fixtures
HPS Smart
Hot Restrike Accessory for HPS Fixtures
Mercmaster fixtures for high pressure sodium lamps can be supplied with a special ignitor (starter
board). It instantly restrikes a hot high pressure sodium lamp when a momentary power interruption
occurs. This special ignitor, supplied in place of the standard ignitor, is a potted solid state device,
totally factory installed. It is not suitable for field installation.
The hot lamp restart option provides instant restart of 50, 70, 100 and 150 W HPS lamps after
power outages of up to 10 seconds. The lamps restrike instantly at almost full lumens. For power
interruptions of up to 30 seconds, the restart of the high pressure sodium lamp is also instant but
at less than full lumens. The hot lamp restart accessory does not accelerate cold lamp start up or
starting where the power outage is of a duration which has allowed the HPS lamp to cool.
Smart
Hot
Restrike
HPS Smart Hot Restrike Accessory
for HPS Fixtures
HPS Smart Hot Restrike Accessory for HPS Fixtures
Accessory Options
Additional Advantages of the Smart Hot Restrike:
• Protects against self destruction in the event of failed, missing or broken lamps, or socket or
Quartzfailure.
Emergency Light
lead wire
• Prevents “End of Life” lamps from continuous cycling over long periods of time.
• Remains unaffected by stray voltages, moderate overvoltages, as well as undervoltage
conditions.
• Drops into the background during normal lamp operation with exceptionally low insertion loss.
• Fully encapsulated construction assures electrical integrity and mechanical vibration protection.
• UL recognized component.
Quartz Emergency Light for Pulse Start Metal Halide or
High Pressure Sodium Fixtures
Description
For fixture watts of 50, 70, 100 or 150 (HPS only)
Catalog Suffix
-SR
Guards: Guards are die-cast copperfree aluminum with baked epoxy finish to match fixtures.
Fixture supplied with stainless steel mounting screws which thread into stainless steel inserts on
fixture housing to attach guard. To order fixture with guard, add suffix -G to catalog number before
adding voltage suffix.
➋ Reflectors: Standard dome and 30° angle polyester reflectors are shown elsewhere in this
catalog section.
➌ Hot Restrike: Instantly restrikes a hot HPS lamp when power is restored after a momentary
outage. Available factory-installed only. To order, add suffix -R to catalog number.
➍ Quartz Emergency Light: When ordered, HPS fixtures will be supplied with a prewired special
DC bayonet base socket to accept a 150W, 120V quartz lamp (not furnished) that automatically
switches on when a power outage occurs. Fixtures ordered with this quartz emergency lamp feature
do NOT comply with requirements for classified areas and should be used only in non-classified
locations. To order, add suffix -E to catalog number and specify if a relay switch is desired.
➎ Photocell and Fuses: Photocontrol are available within the Lighting Section.
Smart Starter: Performs as a conventional starter in lamp start-up. Removes itself from circuit at
end of lamp life or if lamp is out of socket. Add suffix -S to catalog number.
Smart Hot Restrike (HPS only): Will immediately restrike HPS lamp when power is restored after
a momentary power interruption. The smart function removes the hot restrike ignitor from the circuit
if the lamp burns out or is removed from the socket. Eliminates starter failures caused by prolonged
operation with cycling or failing lamps. Add suffix -SR to catalog number.
*NOTE: Fixtures equipped with quartz emergency light do not comply with UL requirements and are not suitable for use in classified locations.
V CSA Certification Only.
944
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
Mercmaster™ III HID 50-250 Watt Luminaires
High Pressure Sodium and Pulse Start Metal Halide
Listed for simultaneous exposure to combustible dusts and flammable gases or vapors.
Class I, Division 2, Groups A, B, C, D
Class I, Zone 2, AEx nA nR IIC (Z2)
Class I, Zone 2, Ex nR IIC (Z) V
Class I, Zone 2, AEx nR IIC (ZB)
Class II, Division 1 and 2, Groups E, F, G
Class III
Simultaneous Exposure (Class I, Division 2/
Class II, Division 1)
Fixtures Outside Type (Salt Water)
Type 4X
IP66
Order using catalog numbering guide below or select catalog number from tables on following pages.
Catalog Numbering Guide
KP
L
70
Lamp Type:
L - High Pressure
Sodium
H or P - Pulse Start
Metal Halide ➊
J5
Hub Size:
75 - 3/4” NPT
10 - 1” NPT
125 - 1-1/4” NPT
stanchion
150 - 1-1/2” NPT
stanchion
Wattage:
10 - 100 W HPS, PSMH
15 - 150 W HPS, PSMH
17 - 175 W PSMH
20 - 200 W PSMH
25 - 250 W PSMH
50 - 50 W HPS
(MT - Voltage Only)
70 - 70 W HPS, PSMH
17 - 175 W MH V
25 - 250 W MH V
G
Guard Options:
G - Guard
Blank - No Guard
Optical Assembly:
Blank - Glass Globe
J1 - NEMA I Glass
Refractor
J3 - NEMA III Glass
Refractor
J5 - NEMA V Glass
Refractor
G3 - Large Glass Globe
MT
R
Z2
Options:
E - Emergency Quartz
F - Fuse Kit (Specify
Voltage)
R - Hot Restrike
(50-150 W HPS
only)
S - Smart Starter
SR - Smart Hot
Restrike
K - Kynar Coating
H1 - Photocontrol
120 V
H2 - Photocontrol
208 V
H3 - Photocontrol
240 V
H4 - Photocontrol
277 V
C - Safety Cable
Adapted V
E40 - Export Socket
D - E-40 Export
Socket V
T - Terminal Blocks V
V - Anti-Vibration
Modifications V
X - Appledapter ➌
Mounting Hood
Adapter V
Voltage: ➋
MT - 120/208/240/277,
60 Hz
5MT - 120/208/240/
277/480, 60 Hz
48 - 480, 60 Hz
125 - 120, 50 Hz
225 - 225, 50 Hz
226 - 220, 60 Hz
235 - 230, 50 Hz
245 - 240, 50 Hz
C2 - 208, 60 Hz, CWI V
C3 - 240, 60 Hz, CWI V
C6 - 480, 60 Hz, CWI V
C7 - 600, 60 Hz, CWI V
TT - 120/277/347, 60 Hz,
CWA V
Lighting: Enclosed and Gasketed — Area — HID
Mounting:
A - Pendant (rigid
mounting)
C - Ceiling
CH - Pendant Cone Hood
F - Pendant (flexible
mounting)
ST - 90° Stanchion
S - 25° Stanchion
WB - Wall
10
Lighting
Series:
KP Mercmaster III
250
A
Suffix:
Z2 - Zone 2 suffix
(required for
AEx nA nR
rating)
ZB - Zone 2 suffix
(required for
AEx nR rating)
Z - Zone 2 suffix
(required for
Ex nR) V
Reflectors are ordered separately – see Accessories page.
➊ H - Lamp type is for 70W and 100W fixtures only.
P - Lamp type is for 175W, 200W and 250W fixtures only.
➋ Voltages shown are limited to specific combinations.
➌ Appledapter is available for use with the pendant, ceiling and angled stanchion mounting only.
V CSA Certification Only.
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
945
Mercmaster™ III HID 50-250 Watt Luminaire Thermal Performance
Class I, Division 2; Class II, Division 1; Simultaneous Exposure to Hazardous Conditions of Both Classifications
Temperature Identification Numbers of Mercmaster III fixtures.
Class I, Division 2, Groups A, B, C, D
Class I, Zone 2, AEx nA nR IIC (Z2)
Class I, Zone 2, Ex nR IIC (Z) V
Class I, Zone 2, AEx nR IIC (ZB)
Class II, Division 1 and 2, Groups E, F, G
Class III
Simultaneous Exposure (Class I, Division 2/
Class II, Division 1)
Fixtures Outside Type (Salt Water)
Type 4X
IP66
Mercmaster III fixtures are listed for “Simultaneous Exposure” to combinations of Class I, Division 2 and Class II, Division 1 hazardous
conditions.
Lighting: Enclosed and Gasketed — Area — HID
Lighting
“T” Numbers for Mercmaster III Fixtures
Lamp
Watts
Type
50
HPS
70
HPS
100
HPS
150
HPS
70
PSMH
100
PSMH
150
PSMH
175
PSMH
200
PSMH
250
PSMH
175
MH V
250
MH V
Supply
Wire
Temp.
(°F/°C)
194/90
194/90
194/90
194/90
194/90
194/90
194/90
194/90
194/90
194/90
194/90
194/90
194/90
194/90
194/90
194/90
194/90
194/90
194/90
194/90
194/90
257/125
194/90
194/90
221/105
194/90
194/90
194/90
194/90
194/90
194/90
194/90
Ambient
Temp.
(°F/°C)
104/40
131/55
149/65
104/40
131/55
149/65
104/40
104/40
131/55
149/65
104/40
104/40
131/55
104/40
131/55
149/65
104/40
131/55
149/65
104/40
131/55
149/65
104/40
131/55
149/65
104/40
131/55
104/40
131/55
104/40
131/55
104/40
Globe
T3C
T3A
T3A
T3B
T3A
T3
T2D
—
T2D
T2D
T2B
—
T2B
T3A
T3A
T3
T3
T3
T2D
T2B
T2A
T2A
T2B
T2A
T2A
T2B
T2B
T2
T2
T2B
T2A
325
Simultaneous Exposure
Class I, Division 2
Class II, Division 1 Groups E, F and G ➊ Class I, Division2 / Class II, Division 1
Globe &
G3
8”
Globe &
G3
8”
Globe &
G3
8”
Reflector Globe Refractor Globe Reflector Globe Refractor Globe Reflector Globe Refractor
T3B
—
T3C
T4A
T4
—
T6
T3A
T3
—
T3C
T3A
—
T3A
T4
T3B
—
T5
T3
T3
—
T3A
T3
—
T3A
T3C
T3C
—
T4A
T2D
T2D
—
T3
T3A
—
T3C
T4
T3C
—
T6
T3
T3
—
T3A
T3A
—
T3B
T3C
T3C
—
T5
T2D
T2D
—
T3
T3A
—
T3A
T3C
T3B
—
T4A
T2C
T2C
—
T3
T2D
T3
T3
—
T3A (EF) T3 (EF)
—
—
—
—
—
—
—
—
T3B
—
T4A
T4A
T2B
T2B
T2C
T2C
T2D
T3
T3
—
—
T4
T4
—
—
T2B
T2B
T2D
T2D
T2D
—
—
—
—
—
—
—
—
T2B
—
T2C
—
—
—
T3C
T2
—
—
T2B
—
—
—
T3 (EF)
—
—
—
—
—
—
—
T2A
—
T2B
—
—
—
—
—
—
—
—
T3A
—
T3A
—
—
—
T3C
—
—
—
—
T3A
—
T3A
—
—
—
T3C
—
—
—
—
T2
—
T3
—
—
—
T3C
—
—
—
—
T3
—
T3
—
—
—
T3C
—
—
—
T2B
T3
—
T3
—
—
—
T3C
—
—
—
T2A
T2D
—
T2D
—
—
—
T3C
—
—
—
—
T2B
—
T2B
—
—
—
T3C
—
—
—
T2B
T2A
—
T2B
—
—
—
T3C
—
—
—
T2A
T2
—
T2B
—
—
—
T3C
—
—
—
—
T2B
—
T2B
—
—
—
T3C
—
—
—
T2B
T2A
—
T2B
—
—
—
T3C
—
—
—
T2A
T2
—
T2B
—
—
—
—
—
—
—
—
T2B
—
T2B
—
—
—
T3B
—
—
—
—
T2B
—
T2B
—
—
—
—
—
—
—
—
T2
—
T2
—
—
—
—
—
—
—
—
T2
—
T2
—
—
—
—
—
—
—
—
T2B
—
T2B
—
—
—
T3C
—
—
—
—
T2A
—
T2B
—
—
—
T3C
—
—
—
—
325
—
T2
—
—
—
T3B
—
—
—
—
“T” Numbers Represent the Maximum Lamp Temperature for Class I, Division 2 Locations and
Maximum Surface Temperature Under Dust Blanket for Class II, Division 1 Locations.
“T”
Number
T1
350
325
T2
T2A
T2B
T2C
T2D
T3
T3A
T3B
T3C
T4
T4A
T5
T6
Temp.
Range
(˚ºF)
664842
619662
574617
538572
502536
448500
421446
394419
358392
331356
322329
277320
250275
214248
187212
185
Temp.
Range
(°C)
351450
326350
301325
281300
261280
231260
216230
201215
181200
166180
161165
136160
121135
101120
86100
85
➊ All Class II T Numbers are E, F, G unless otherwise indicated.
V CSA Certification Only.
946
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
Mercmaster™ III HID 50-250 Watt Luminaire Thermal Performance
Class I, Zone 2, AEx nA nR IIC; Class 1 Zone 2, AEx nR IIC; IP66; and NEMA 4X
Temperature Identification Numbers of Mercmaster III Fixtures.
Class I, Division 2, Groups A, B, C, D
Class I, Zone 2, AEx nA nR IIC (Z2)
Class I, Zone 2, Ex nR IIC (Z) V
Class I, Zone 2, AEx nR IIC (ZB)
Class II, Division 1 and 2, Groups E, F, G
Class III
Simultaneous Exposure (Class I, Division 2/
Class II, Division 1)
Fixtures Outside Type (Salt Water)
Type 4X
IP66
Operating Temperatures: “T” Numbers for Zone 2 Mercmaster III Fixtures
The “T” number is established by separately determining the maximum temperature of the globe surface and ballast compartment. The hotter of the two is taken
to determine the “T” number for the overall fixture.
Watts
Type
50
HPS
100
150
70
100
150
175
200
250
HPS
HPS
HPS
PSMH
PSMH
PSMH
PSMH
PSMH
PSMH
Ambient
Temp.
(°F/°C)
104/40
Globe
T4
Globe &
Reflector
T4
Refractor
Only
T6
G3/Refractor
& Reflector
T4
Globe
T4
Globe &
Reflector
T4
Refractor
Only
T6
G3/Refractor
& Reflector
T4
194/90
131/55
T4
T3
T5
T3
T4
T3
T5
T3
194/90
149/65
T3
T3
T4
T3
T3
T3
T4
T3
194/90
104/40
T4
T4
T4
T4
T6
T5
T6
T4
194/90
131/55
T4
T4
T4
T3
T5
T4
T5
T3
194/90
149/65
T4
T4
T3
T3
T4
T4
T5
T3
194/90
104/40
T4
T4
T4
T4
T5
T4
T6
T4
194/90
131/55
T4
T4
T3
T3
T4
T4
T5
T3
194/90
149/65
T4
T4
T3
T3
T4
T4
T4
T3
194/90
104/40
T4
T3
T3
T3
T4
T4
T5
T4
194/90
131/55
T3
T3
T3
T3
T4
T4
T4
T3
221/105
65
T3
T3
T3
T3
T4
T3
T4
T3
194/90
104/40
T4
T4
T4
—
T5
T4
T6
—
194/90
131/55
T3
T3
T3
—
T4
T4
T5
—
194/90
149/65
T3
T3
T3
—
T4
T3
T4
—
194/90
104/40
T3
T3
T3
—
T5
T4
T6
—
194/90
131/55
T3
T3
T3
—
T4
T4
T5
—
194/90
149/65
T3
T3
T3
—
T4
T3
T4
—
194/90
104/40
T4
T4
T4
—
T4
T4
T5
—
Class I, Zone 2 AEx nA nR IIC
Class I, Zone 2 AEx nR IIC
194/90
131/55
T3
T3
T3
—
T4
T3
T4
—
221/105
149/65
T3
T3
T3
—
T4
T3
T4
—
194/90
104/40
T3
T3
T4
—
T3
T3
T4
—
194/90
131/55
T3
T3
T3
—
T3
T3
T4
—
221/105
149/65
T3
T3
T3
—
T3
T3
T4
—
194/90
104/40
T3
T3
T4
—
T3
T3
T4
—
221/105
131/55
T3
T3
T3
—
T3
T3
T4
—
221/105
149/65
T3
T3
T3
—
T3
T3
T4
—
194/90
104/40
T3
T3
T3
—
T3
T3
T3
—
194/90
131/55
T3
T3
T3
—
T3
T3
T3
—
Lighting: Enclosed and Gasketed — Area — HID
70
Supply
Wire
Temp.
(°F/°C)
194/90
“T” Numbers Represent the Maximum Surface Temperature for Luminaries with AEx nA nR or AEx nR rating
“T” Number
T1
T2
T3
T4
T5
T6
Temp. Range (°F)
547-842
394-572
277-392
214-275
187-212
185
Temp. Range (°C)
301-450
201-300
136-200
101-135
86-100
85
V CSA Certification Only.
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
Lighting
Lamp
947
Mercmaster™ III HID 50-250 Watt Luminaire Classified Area Suitability
Class I, Division 2; Class II, Division 1; Simultaneous Exposure to Hazardous Conditions of Both Classifications
Maximum Temperatures in °F/°C Obtained from Tests in a 104 °F/40 °C Ambient, Vertical Position, Lamp Base Up, as per NEC.
Class I, Division 2, Groups A, B, C, D
Class I, Zone 2, AEx nA nR IIC (Z2)
Class I, Zone 2, Ex nR IIC (Z) V
Class I, Zone 2, AEx nR IIC (ZB)
Class II, Division 1 and 2, Groups E, F, G
Class III
Simultaneous Exposure (Class I, Division 2/
Class II, Division 1)
Fixtures Outside Type (Salt Water)
Type 4X
IP66
Fixture Selection Guide Indicates atmosphere for which fixture is suitable
Lighting
Denotes fixture with Globe Only. ➋ Denotes fixture with Globe and Reflector. ➌ Denotes fixture with 8” Refractor / G3 Globe
Ignition
°F/°C ➍
Minimum Fixture
“T” Number for
Chemical
581/305
T2
acrolein (inhibited)
428/220
arsine
butadiene
ethylene oxide
hydrogen
propylene oxide
propylnitrate
NA ➋
788/420
804/429
932/500
840/449
347/175
acetaldehyde
allyl alcohol
n-butyraldehyde
carbon monoxide
crotonaldehyde
cyclopropane
diethyl ether (ethyl ether)
diethylamine
ethylene
ethylenimine
Class I, Division 2 Chemical
Group A Atmospheres
acetylene
HPS (Watts)
50
70
100
PSMH (Watts)
150
70
100
175
➋➌ ➋➌ ➋➌ ➋➌
➋
➋➌ ➋➌
T2D
➋➌ ➋➌ ➋➌
➋
➋➌
350
350
T1
350
T3B
➋➌
➋➌
➋➌
➋➌
➋➌
➋➌
➋➌
➋➌
➋➌
➋➌
➋
➋
➋
➋
➋
➋➌
➋➌
➋➌
➋➌
347/175
712/378
424/218
1128/609
450/232
928/498
320/160
594/312
842/450
608/320
T3B
350
T2D
T1
T2C
T1
T3C
T2
T1
T2
➋➌
➋➌
➋➌
➋➌
➋➌
➋➌
➌
➋➌
➋➌
➋➌
➊ ➌
➋➌
➋➌
➋➌
➋➌
➋➌
➌
➋➌
➋➌
➋➌
ethly mercaptan
572/300
ethyl sulfide
hydrogen cyanide
200
250
➌
➋
Lighting: Enclosed and Gasketed — Area — HID
Group B Atmospheres
➋➌
➋➌
➋➌
➋➌
➋➌
➋➌
➋➌
➋➌
➋
➋➌
➋➌
➋➌
➋➌
➋➌
➋➌
➋➌
➋➌
➋
➋
➋
➋
➋➌ ➋➌ ➋➌
➋➌
➋➌ ➋➌ ➋➌
➋➌
➋➌ ➋➌ ➋➌
➋
➋
➋
➋
➋
➋➌ ➋➌ ➌
➋➌ ➋➌ ➋➌
➋➌ ➋➌ ➌
➋
➋
➋
Group C Atmospheres
➋➌ ➋➌
➋➌ ➋➌
➋➌ ➋➌
➋
➋
➋
➋
➋
➋
➋
➋
➋
➋
T2
➋➌ ➋➌ ➋➌ ➋➌
➋
➋➌ ➋➌
➌
➋
NA ➎
1000/538
T1
➋➌ ➋➌ ➋➌ ➋➌
➋
➋➌ ➋➌ ➋➌
➋
hydrogen sulfide
500/260
T2B
➋➌ ➋➌ ➋➌ ➋➌
➋
➋➌ ➋➌
morpholine
2-nitropropane
tetrahydrofuran
unsymmetrical dimethyl hydrazine
590/310
802/428
610/321
480/249
T2
350
T2
T2C
➋➌
➋➌
➋➌
➋➌
➋➌
➋➌
➋➌
➋➌
➋➌ ➋➌
➋➌ ➋➌
➋➌ ➋➌
➋➌
➌
➋
➋
➋
➋
➋➌ ➋➌ ➌
➋➌ ➋➌ ➋➌
➋➌ ➋➌ ➌
➋➌
➋
➋
➋
➋
867/464
869/465
898/481
1204/651
928/498
549/287
649/343
T1
T1
T1
T1
T1
T2A
325
➋➌
➋➌
➋➌
➋➌
➋➌
➋➌
➋➌
➋➌
➋➌
➋➌
➋➌
➋➌
➋➌
➋➌
➋➌
➋➌
➋➌
➋➌
➋➌
➋➌
➋➌
➋
➋
➋
➋
➋
➋
➋
➋➌
➋➌
➋➌
➋➌
➋➌
➋➌
➋➌
➋
➋
➋
➋
➋
➋
➋
➋➌ ➋➌
➋➌
➋➌ ➋➌
➋➌
➌
➋➌ ➋➌
➋
Group D Atmospheres
acetic acid (glacial)
acetone
acrylonitrile
ammonia
benzene
butane
1-butanol (butyl alcohol)
➋➌
➋➌
➋➌
➋➌
➋➌
➋➌
➋➌
➋➌
➋➌
➋➌
➋➌
➋➌
➋➌
➋➌
➋➌
➋➌
➋➌
➋➌
➋➌
➋➌
This classified area suitability chart is based on NEC requirements and Appleton and UL testing. However, the ultimate decision on suitability of these fixtures for
classified areas depends solely on the judgement of the owner, insurance company, inspector and/or authority having jurisdiction.
➍ Ignition temperatures shown should be regarded as approximations only. Per NFPA Bulletin 325M, ignition temperatures may vary according to such factors
as vapor/air mixture, size and space where ignition may occur, rate and duration of heating, oxygen concentration and other materials present.
➎ Not Available.
➏ A saturated hydrocarbon mixture. Also known by synonyms benzine, ligroin, petroleum, ether and naptha.
V CSA Certification Only.
948
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
Mercmaster™ III HID 50-250 Watt Classified Area Suitability
Class I, Division 2; Class II, Division 1; Simultaneous Exposure to Hazardous Conditions of Both Classifications
Maximum Temperatures in °F/°C Obtained from Tests in a 104 °F/40 °C Ambient, Vertical Position, Lamp Base Up, as per NEC.
Class I, Division 2, Groups A, B, C, D
Class I, Zone 2, AEx nA nR IIC (Z2)
Class I, Zone 2, Ex nR IIC (Z) V
Class I, Zone 2, AEx nR IIC (ZB)
Class II, Division 1 and 2, Groups E, F, G
Class III
Simultaneous Exposure (Class I, Division 2/
Class II, Division 1)
Fixtures Outside Type (Salt Water)
Type 4X
IP66
Fixture Selection Guide Indicates atmosphere for which fixture is suitable
Denotes fixture with Globe Only. ➋ Denotes fixture with Globe and Reflector. ➌ Denotes fixture with 8” Refractor / G3 Globe
PSMH (Watts)
761/405
797/425
350
350
➋➌ ➋➌ ➋➌ ➋➌
➋➌ ➋➌ ➋➌ ➋➌
➋
➋
➋➌ ➋➌ ➋➌
➋➌ ➋➌ ➋➌
➋
➋
isobutyl acetate
790/421
350
➋➌ ➋➌ ➋➌ ➋➌
➋
➋➌ ➋➌ ➋➌
➋
sec-butyl alcohol
di-isobutylene
ethane
ethanol (ethyl alcohol)
ethyl acetate
ethylene diamine (anhydrous)
ethylene dichloride
gasoline (56-60 octane)
heptanes
hexanes
isoprene
isopropyl ether
mesityl oxide
methane (natural gas)
methanol (methyl alcohol)
3-methyl-l-butanol (isoamyl alcohol)
methyl ethyl ketone
methyl isobutyl ketone
2-methyl-1-propanol (isobutyl alcohol)
2-methyl-1-propanol (tertiary butyl alcohol)
petroleum naphtha ➏
pyridine
octanes
pentanes
1-pentanol (amyl alcohol)
propane
1-propanol (propyl alcohol)
2-propanol (isopropyl alcohol)
propylene
styrene
toluene
vinyl acetate
649/343
736/391
882/472
685/363
799/426
725/385
775/413
536/280
399/204
433/223
743/395
829/443
651/344
999/537
725/385
662/350
759/404
838/448
779/415
892/478
550/288
900/482
403/206
500/260
572/300
810/432
774/412
750/399
851/455
914/490
896/480
756/402
325
350
T1
350
350
350
350
T2A
T3
T2D
350
350
325
T1
350
350
350
350
350
T1
T2A
T1
T3
T2B
T2
350
350
350
T1
T1
T1
350
➋➌
➋➌
➋➌
➋➌
➋➌
➋➌
➋➌
➋➌
➋➌
➋➌
➋➌
➋➌
➋➌
➋➌
➋➌
➋➌
➋➌
➋➌
➋➌
➋➌
➋➌
➋➌
➋➌
➋➌
➋➌
➋➌
➋➌
➋➌
➋➌
➋➌
➋➌
➋➌
➋➌
➋➌
➋➌
➋➌
➋➌
➋➌
➋➌
➋➌
➋➌
➋
➋
➋
➋
➋
➋
➋
➋
➋
➋
➋
➋
➋
➋
➋
➋
➋
➋
➋
➋
➋
➋
➋
➋
➋
➋
➋
➋
➋
➋
➋
➋
➋➌
➋➌
➋➌
➋➌
➋➌
➋➌
➋➌
➋➌
➋➌
➋➌
➋➌
➋➌
➋➌
➋➌
➋➌
➋➌
➋➌
➋➌
➋➌
➋➌
➋➌
➋➌
➋➌
➋➌
➋➌
➋➌
➋➌
➋➌
➋➌
➋➌
➋➌
➋➌
vinyl chloride
882/472
T1
➋➌ ➋➌ ➋➌ ➋➌
xylenes (o-xylene)
865/463
T1
➋➌ ➋➌ ➋➌ ➋➌
50
70
➋➌
➋➌
➋➌
➋➌
➋➌
➋➌
➋➌
➋➌
➋➌
➋➌
➋➌
➋➌
➋➌
➋➌
➋➌
➋➌
➋➌
➋➌
➋➌
➋➌
➋➌
➋➌
➋➌
➋➌
➋➌
➋➌
➋➌
➋➌
➋➌
➋➌
➋➌
➋➌
100
➋➌
➋➌
➋➌
➋➌
➋➌
➋➌
➋➌
➋➌
➋➌
➋
➋
➋
➋
➋➌
➋➌
➋➌
➋➌
➋➌
➋➌
➋➌
➋➌
➋➌
➋➌
➋➌
➋➌
➋➌
150
➋➌
➋➌
➋➌
➋➌
➋➌
➋➌
➋➌
➋➌
➋➌
➋➌
➋➌
➋➌
➋➌
➋➌
➋➌
➋➌
➋➌
➋➌
➋➌
➋➌
70
100
175
200
250
➋➌
➋➌
➋➌
➋➌
➋➌
➋➌
➋➌
➋➌
➋➌
➋➌
➋➌
➋➌
➋➌
➋➌
➋➌
➋
➋
➋
➋
➋
➋
➋
➋
➋➌
➋➌
➋➌
➋➌
➋➌
➋➌
➋➌
➋➌
➋➌
➋➌
➋➌
➋➌
➋➌
➋➌
➋➌
➋➌
➋➌
➋➌
➋➌
➋➌
➋➌
➋➌
➋➌
➋
➋
➋
➋
➋
➋
➋
➋
➋
➋
➋
➋
➋➌
➋➌
➋➌
➋➌
➋➌
➋➌
➋➌
➋➌
➋➌
➋➌
➋➌
➋➌
➋➌
➋➌
➋➌
➋
➋
➋
➋
➋
➋
➋
➋
➋
➋
➋➌ ➋➌ ➋➌
➋
➋
➋➌ ➋➌ ➋➌
➋
This classified area suitability chart is based on NEC requirements and Appleton and UL testing. However, the ultimate decision on suitability of these fixtures for
classified areas depends solely on the judgement of the owner, insurance company, inspector and/or authority having jurisdiction.
➍ Ignition temperatures shown should be regarded as approximations only. Per NFPA Bulletin 325M, ignition temperatures may vary according to such factors
as vapor/air mixture, size and space where ignition may occur, rate and duration of heating, oxygen concentration and other materials present.
➎ Not Available.
➏ A saturated hydrocarbon mixture. Also known by synonyms benzine, ligroin, petroleum, ether and naptha.
V CSA Certification Only.
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
949
Lighting: Enclosed and Gasketed — Area — HID
Class I, Division 2 Chemical
Group D Atmospheres
2-butanol (secondary butyl alcohol)
n-butyl acetate
Minimum Fixture
“T” Number for
Chemical
Lighting
HPS (Watts)
Ignition
°F/°C ➍
Mercmaster™ III HID 50-250 Watt Luminaire Classified Area Suitability
Class I, Zone 2, AEx nA nR IIC; Class 1 Zone 2, AEx nR IIC; IP66; and NEMA 4X
Maximum Temperatures in ºF/ºC Obtained from Tests in a 104 ºF/40 ºC Ambient, Vertical Position, Lamp Base Up.
Class I, Division 2, Groups A, B, C, D
Class I, Zone 2, AEx nA nR IIC (Z2)
Class I, Zone 2, Ex nR IIC (Z) V
Class I, Zone 2, AEx nR IIC (ZB)
Class II, Division 1 and 2, Groups E, F, G
Class III
Simultaneous Exposure (Class I, Division 2/
Class II, Division 1)
Fixtures Outside Type (Salt Water)
Type 4X
IP66
Fixture Selection Guide Indicates atmosphere for which fixture is suitable
Lighting: Enclosed and Gasketed — Area — HID
Lighting
➋ Denotes fixture with Globe and Reflector. ➌ Denotes fixture with 8” Refractor.
HPS (Watts)
PSMH (Watts)
Ignition
°F/°C ➍
Minimum Fixture
“T” Number for
Chemical
50
70
100
150
70
100
175
200
250
acetylene
581/305
T2
➋➌
➋➌
➋➌
➋➌
➋➌
➋➌
➋➌
➋➌
➋➌
acetylene
572/300
T2
➋➌
➋➌
➋➌
➋➌
➋➌
➋➌
➋➌
➋➌
➋➌
hydrogen
932/500
T1
➋➌
➋➌
➋➌
➋➌
➋➌
➋➌
➋➌
➋➌
➋➌
914/490
T1
➋➌
➋➌
➋➌
➋➌
➋➌
➋➌
➋➌
➋➌
➋➌
butadiene 1.3
797/425
T2
➋➌
➋➌
➋➌
➋➌
➋➌
➋➌
➋➌
➋➌
➋➌
carbon monoxide coke oven gas
1040/560
T1
➋➌
➋➌
➋➌
➋➌
➋➌
➋➌
➋➌
➋➌
➋➌
diethyl ether (ethyl ether)
320/160
T4
➋➌
➋➌
➋➌
➋➌
➋➌
ethylene
842/450
T1
➋➌
➋➌
➋➌
➋➌
➋➌
➋➌
➋➌
➋➌
➋➌
ethylenimine ethylene oxide
797/425
T2
➋➌
➋➌
➋➌
➋➌
➋➌
➋➌
➋➌
➋➌
➋➌
acetone
869/465
T1
➋➌
➋➌
➋➌
➋➌
➋➌
➋➌
➋➌
➋➌
➋➌
amyl acetate
707/375
T2
➋➌
➋➌
➋➌
➋➌
➋➌
➋➌
➋➌
➋➌
➋➌
ammonia
1204/651
T1
➋➌
➋➌
➋➌
➋➌
➋➌
➋➌
➋➌
➋➌
➋➌
benzene
928/498
T1
➋➌
➋➌
➋➌
➋➌
➋➌
➋➌
➋➌
➋➌
➋➌
butane
549/287
T3
➋➌
➋➌
➋➌
➋➌
➋➌
➋➌
➋➌
➋➌
1-butanol (butyl alcohol)
649/343
T2
➋➌
➋➌
➋➌
➋➌
➋➌
➋➌
➋➌
➋➌
n-butyl acetate cyclohexane
500/260
T3
➋➌
➋➌
➋➌
➋➌
➋➌
➋➌
➋➌
➋➌
ethyl methyl ketone
959/515
T1
➋➌
➋➌
➋➌
➋➌
➋➌
➋➌
➋➌
➋➌
➋➌
ethanol (ethyl alcohol)
685/363
T2
➋➌
➋➌
➋➌
➋➌
➋➌
➋➌
➋➌
➋➌
➋➌
ethyl acetate
799/426
T1
➋➌
➋➌
➋➌
➋➌
➋➌
➋➌
➋➌
➋➌
➋➌
heptanes
399/204
T3
➋➌
➋➌
➋➌
➋➌
➋➌
➋➌
➋➌
➋➌
hexanes
433/223
T3
➋➌
➋➌
➋➌
➋➌
➋➌
➋➌
➋➌
➋➌
isoprene isobutanol
806/430
T2
➋➌
➋➌
➋➌
➋➌
➋➌
➋➌
➋➌
➋➌
➋➌
mesityl oxide methyl acetate
932/500
T1
➋➌
➋➌
➋➌
➋➌
➋➌
➋➌
➋➌
➋➌
➋➌
methanol (methyl alcohol)
725/385
T2
➋➌
➋➌
➋➌
➋➌
➋➌
➋➌
➋➌
➋➌
➋➌
n-propyl acetate
932/500
T1
➋➌
➋➌
➋➌
➋➌
➋➌
➋➌
➋➌
➋➌
➋➌
n-butul acetate
788/420
T2
➋➌
➋➌
➋➌
➋➌
➋➌
➋➌
➋➌
➋➌
➋➌
pentanes
500/260
T3
➋➌
➋➌
➋➌
➋➌
➋➌
➋➌
➋➌
➋➌
propane
810/432
T2
➋➌
➋➌
➋➌
➋➌
➋➌
➋➌
➋➌
➋➌
➋➌
xylenes (o-xylene)
865/463
T1
➋➌
➋➌
➋➌
➋➌
➋➌
➋➌
➋➌
➋➌
➋➌
Class I, Division 2 Chemical
Group IIC
Group IIB
ethylene
Group IIA
➋➌
This classified area suitability chart is based on NEC requirements and Appleton and UL testing. However, the ultimate decision on suitability of these fixtures for
classified areas depends solely on the judgement of the owner, insurance company, inspector and/or authority having jurisdiction.
➍ Ignition temperatures shown should be regarded as approximations only. Per NFPA Bulletin 325M, ignition temperatures may vary according to such factors
as vapor/air mixture, size and space where ignition may occur, rate and duration of heating, oxygen concentration and other materials present.
V CSA Certification Only.
950
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
Mercmaster™ III HID 50-250 Watt Luminaires
50 W, 70 W, 100 W, 150 W HPS
High Reactance, High Power Factor (min. P.F. 90%). Heat-Resistant Prismatic Glass Globe or Closed Prismatic Glass Refractor. Mogul Base Lamps.
Class I, Division 2, Groups A, B, C, D
Class I, Zone 2, AEx nA nR IIC (Z2)
Class I, Zone 2, Ex nR IIC (Z) V
Class I, Zone 2, AEx nR IIC (ZB)
Class II, Division 1 and 2, Groups E, F, G
Class III
Simultaneous Exposure (Class I, Division 2/
Class II, Division 1)
Lamp Type
Lamp Watts
Hub Size
(Inches)
Fixtures Outside Type (Salt Water)
Type 4X
IP66
Catalog Numbers ➌➍➎
with Type V 8” Refractor
with Globe
or G3 Globe ➋
HPS
HPS
HPS
70
100
150
3/4
KPAL5075
KPAL5075J5
1
KPAL5010
KPAL5010J5
3/4
KPAL7075
KPAL7075J5
1
KPAL7010
KPAL7010J5
3/4
KPAL1075
KPAL1075J5
1
KPAL1010
KPAL1010J5
3/4
KPAL1575
KPAL1575J5
1
KPAL1510
KPAL1510J5
3/4
KPCHL5075
KPCHL5075J5
1
KPCHL5010
KPCHL5010J5
3/4
KPCHL7075
KPCHL7075J5
1
KPCHL7010
KPCHL7010J5
3/4
KPCHL1075
KPCHL1075J5
1
KPCHL1010
KPCHL1010J5
3/4
KPCHL1575
KPCHL1575J5
1
KPCHL1510
KPCHL1510J5
3/4
KPCL5075
KPCL5075J5
1
KPCL5010
KPCL5010J5
3/4
KPCL7075
KPCL7075J5
1
KPCL7010
KPCL7010J5
3/4
KPCL1075
KPCL1075J5
1
KPCL1010
KPCL1010J5
3/4
KPCL1575
KPCL1575J5
1
KPCL1510
KPCL1510J5
Lighting: Enclosed and Gasketed — Area — HID
HPS
50
Lighting
Pendant — One Hub, Rigid Mounting ➊
Pendant Cone — One Hub, Rigid Mounting
HPS
50
HPS
70
HPS
100
HPS
150
Ceiling — Five Hubs, Four Close-Up Plugs
HPS
50
HPS
70
HPS
100
HPS
150
➊ For Flexible Pendant Mount, change A to F in catalog number (except 50 W HPS).
➋ To order fixtures with large globe change J5 to G3; for fixture with NEMA Type I or NEMA Type III refractor, change final digit 5 in catalog number to 1 or 3.
➌ Add the following voltage and frequency designation before Z2 suffix:
Voltage Suffixes
Lamp Type Lamp Watts
MT
5MT
48
125
225
226
235
245
C2 V
C3 V
C6 V
C7 V
TT V
HPS
50
X
—
—
—
X
X
—
X
—
—
—
—
X
HPS
70
X
—
X
X
X
X
—
X
—
—
—
—
X
HPS
100
X
—
X
X
X
X
—
X
—
—
X
X
X
HPS
150
X
—
X
X
X
X
—
X
—
—
X
X
X
PSMH
70
X
—
X
X
X
—
—
X
—
—
—
—
X
PSMH
100
X
—
X
X
X
—
—
X
—
—
—
—
X
PSMH
150
X
—
X
X
X
—
—
X
—
—
—
—
X
PSMH
175
X
X
X
—
—
—
—
—
—
—
—
—
X
PSMH
200
X
—
X
—
—
—
—
—
—
—
—
—
X
PSMH
250
X
—
—
—
—
—
—
—
—
—
—
—
X
175
X
—
—
X
X
—
—
X
X
X
X
X
X
MH V
250
X
—
—
X
X
—
—
X
X
X
X
X
X
MH V
245 - 240 V 50 Hz
Voltages:
125 - 120 V 50 Hz
MT - 120/208/240/277 V 60 Hz
225 - 225 V 50 Hz
C2 - 208 V 60 Hz, CWI V
5MT - 120/208/240/277/480 V 60 Hz
226 - 220 V 60 Hz
C3 - 240 V 60 Hz, CWI V
C7 - 600 V 60 Hz, CWI V,
48 - 480 V 60 Hz
235 - 230 V 50 Hz
C6 - 480 V 60 Hz, CWI V
TT - 120/277/347 V 60 Hz, CWA V
➍ Add -Z2 suffix for factory sealed non-sparking/restricted breathing protection (AEx nA nR). Add -ZB suffix for restricted breathing protection (AEx nR).
➎ For fixtures with guards, add letter G before adding voltage designation.
V CSA Certification only.
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
951
Mercmaster™ III HID 50-250 Watt Luminaires
50 W, 70 W, 100 W, 150 W HPS
High Reactance, High Power Factor (min. P.F. 90%). Heat-Resistant Prismatic Glass Globe or Closed Prismatic Glass Refractor. Mogul Base Lamps.
Class I, Division 2, Groups A, B, C, D
Class I, Zone 2, AEx nA nR IIC (Z2)
Class I, Zone 2, Ex nR IIC (Z) V
Class I, Zone 2, AEx nR IIC (ZB)
Class II, Division 1 and 2, Groups E, F, G
Class III
Simultaneous Exposure (Class I, Division 2/
Class II, Division 1)
Lighting
Lamp Type
Wall — Five Hubs, Four Close-Up Plugs
HPS
50
HPS
70
HPS
Lighting: Enclosed and Gasketed — Area — HID
Lamp Watts
100
HPS
150
HPS
50
Hub Size
(Inches)
Fixtures Outside Type (Salt Water)
Type 4X
IP66
Catalog Numbers ➌➍➎
with Type V 8” Refractor
with Globe
or G3 Globe ➋
3/4
KPWBL5075
KPWBL5075J5
1
KPWBL5010
KPWBL5010J5
3/4
KPWBL7075
KPWBL7075J5
1
KPWBL7010
KPWBL7010J5
3/4
KPWBL1075
KPWBL1075J5
1
KPWBL1010
KPWBL1010J5
3/4
KPWBL1575
KPWBL1575J5
1
KPWBL1510
KPWBL1510J5
1-1/4
KPSL50125
KPSL50125J5
1-1/2
KPSL50150
KPSL50150J5
1-1/4
KPSL70125
KPSL70125J5
1-1/2
KPSL70150
KPSL70150J5
1-1/4
KPSL10125
KPSL10125J5
1-1/2
KPSL10150
KPSL10150J5
1-1/4
KPSL15125
KPSL15125J5
1-1/2
KPSL15150
KPSL15150J5
1-1/4
KPSTL50125
KPSTL50125J5
1-1/2
KPSTL50150
KPSTL50150J5
1-1/4
KPSTL70125
KPSTL70125J5
1-1/2
KPSTL70150
KPSTL70150J5
1-1/4
KPSTL10125
KPSTL10125J5
1-1/2
KPSTL10150
KPSTL10150J5
1-1/4
KPSTL15125
KPSTL15125J5
1-1/2
KPSTL15150
KPSTL15150J5
25° Stanchion — One Hub
HPS
70
HPS
100
HPS
150
HPS
50
90° Stanchion — One Hub
HPS
HPS
HPS
70
100
150
➊ For Flexible Pendant Mount, change A to F in catalog number (except 50 W HPS).
➋ To order fixtures with large globe change J5 to G3; for fixture with NEMA Type I or NEMA Type III refractor, change final digit 5 in catalog number to 1 or 3.
➌ Add the following voltage and frequency designation before Z2 suffix:
Voltage Suffixes
Lamp Type Lamp Watts
MT
5MT
48
125
225
226
235
245
C2 V
C3 V
C6 V
C7 V
TT V
HPS
50
X
—
—
—
X
X
—
X
—
—
—
—
X
HPS
70
X
—
X
X
X
X
—
X
—
—
—
—
X
HPS
100
X
—
X
X
X
X
—
X
—
—
X
X
X
HPS
150
X
—
X
X
X
X
—
X
—
—
X
X
X
PSMH
70
X
—
X
X
X
—
—
X
—
—
—
—
X
PSMH
100
X
—
X
X
X
—
—
X
—
—
—
—
X
PSMH
150
X
—
X
X
X
—
—
X
—
—
—
—
X
PSMH
175
X
X
X
—
—
—
—
—
—
—
—
—
X
PSMH
200
X
—
X
—
—
—
—
—
—
—
—
—
X
PSMH
250
X
—
—
—
—
—
—
—
—
—
—
—
X
175
X
—
—
X
X
—
—
X
X
X
X
X
X
MH V
250
X
—
—
X
X
—
—
X
X
X
X
X
X
MH V
Voltages:
125 - 120 V 50 Hz
245 - 240 V 50 Hz
MT - 120/208/240/277 V 60 Hz
225 - 225 V 50 Hz
C2 - 208 V 60 Hz, CWI V
5MT - 120/208/240/277/480 V 60 Hz
226 - 220 V 60 Hz
C3 - 240 V 60 Hz, CWI V
C7 - 600 V 60 Hz, CWI V,
235 - 230 V 50 Hz
C6 - 480 V 60 Hz, CWI V
TT - 120/277/347 V 60 Hz, CWA V
48 - 480 V 60 Hz
➍ Add -Z2 suffix for factory sealed non-sparking/restricted breathing protection (AEx nA nR). Add -ZB suffix for restricted breathing protection (AEx nR).
➎ For fixtures with guards, add letter G before adding voltage designation.
V CSA Certification only.
952
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
Mercmaster™ III HID 50-250 Watt
70 W, 100 W, 150 W, 175 W, 200 W, 250 W PSMH
High Reactance, High Power Factor (min. P.F. 90%). Heat-Resistant Prismatic Glass Globe or Closed Prismatic Glass Refractor. Mogul Base Lamps
Class I, Division 2, Groups A, B, C, D
Class I, Zone 2, AEx nA nR IIC (Z2)
Class I, Zone 2, Ex nR IIC (Z) V
Class I, Zone 2, AEx nR IIC (ZB)
Class II, Division 1 and 2, Groups E, F, G
Class III
Simultaneous Exposure (Class I, Division 2/
Class II, Division 1)
Lamp Type
Pendant — One Hub, Rigid Mounting ➊
Lamp Watts
PSMH
100
PSMH
150
PSMH
175
PSMH
200
PSMH
250 ➏
Pendant Cone — One Hub, Rigid Mounting
PSMH
70
PSMH
100
PSMH
150
PSMH
175
PSMH
200
PSMH
250 ➏
Ceiling — Five Hubs, Four Close-Up Plugs
PSMH
70
PSMH
100
PSMH
150
PSMH
175
PSMH
200
PSMH
250 ➏
3/4
1
3/4
1
3/4
1
3/4
1
3/4
1
3/4
1
KPAH7075
KPAH7010
KPAH1075
KPAH1010
KPAP1575
KPAP1510
KPAP1775
KPAP1710
KPAP2075
KPAP2010
KPAP2575
KPAP2510
KPAH7075J5
KPAH7010J5
KPAH1075J5
KPAH1010J5
KPAP1575J5
KPAP1510J5
KPAP1775J5
KPAP1710J5
KPAP2075J5
KPAP2010J5
KPAP2575J5
KPAP2510J5
3/4
1
3/4
1
3/4
1
3/4
1
3/4
1
3/4
1
KPCHH7075
KPCHH7010
KPCHH1075
KPCHH1010
KPCHP1575
KPCHP1510
KPCHP1775
KPCHP1710
KPCHP2075
KPCHP2010
KPCHP2575
KPCHP2510
KPCHH7075J5
KPCHH7010J5
KPCHH1075J5
KPCHH1010J5
KPCHP1575J5
KPCHP1510J5
KPCHP1775J5
KPCHP1710J5
KPCHP2075J5
KPCHP2010J5
KPCHP2575J5
KPCHP2510J5
3/4
1
3/4
1
3/4
1
3/4
1
3/4
1
3/4
1
KPCH7075
KPCH7075
KPCH1075
KPCH1010
KPCP1575
KPCP1510
KPCP1775
KPCP1710
KPCP2075
KPCP2010
KPCP2575
KPCP2510
KPCH7075J5
KPCH7010J5
KPCH1075J5
KPCH1010J5
KPCP1575J5
KPCP1510J5
KPCP1775J5
KPCP1710J5
KPCP2075J5
KPCP2010J5
KPCP2575J5
KPCP2510J5
Lighting: Enclosed and Gasketed — Area — HID
70
Catalog Numbers ➌➍➎
with Globe
with Type V 8” Refractor ➋
Lighting
PSMH
Hub Size
(Inches)
Fixtures Outside Type (Salt Water)
Type 4X
IP66
➊ For Flexible Pendant Mount, change A to F in catalog number (except 50 W HPS).
➋ To order fixtures with large globe change J5 to G3; for fixture with NEMA Type I or NEMA Type III refractor, change final digit 5 in catalog number to 1 or 3.
➌ Add the following voltage and frequency designation before Z2 suffix:
Voltage Suffixes
Lamp Type Lamp Watts
MT
5MT
48
125
225
226
235
245
C2 V
C3 V
C6 V
C7 V
TT V
HPS
50
X
—
—
—
X
X
—
X
—
—
—
—
X
HPS
70
X
—
X
X
X
X
—
X
—
—
—
—
X
HPS
100
X
—
X
X
X
X
—
X
—
—
X
X
X
HPS
150
X
—
X
X
X
X
—
X
—
—
X
X
X
PSMH
70
X
—
X
X
X
—
—
X
—
—
—
—
X
PSMH
100
X
—
X
X
X
—
—
X
—
—
—
—
X
PSMH
150
X
—
X
X
X
—
—
X
—
—
—
—
X
PSMH
175
X
X
X
—
—
—
—
—
—
—
—
—
X
PSMH
200
X
—
X
—
—
—
—
—
—
—
—
—
X
PSMH
250
X
—
—
—
—
—
—
—
—
—
—
—
X
175
X
—
—
X
X
—
—
X
X
X
X
X
X
MH V
250
X
—
—
X
X
—
—
X
X
X
X
X
X
MH V
Voltages:
125 - 120 V 50 Hz
245 - 240 V 50 Hz
MT - 120/208/240/277 V 60 Hz
225 - 225 V 50 Hz
C2 - 208 V 60 Hz, CWI V
5MT - 120/208/240/277/480 V 60 Hz
226 - 220 V 60 Hz
C3 - 240 V 60 Hz, CWI V
C7 - 600 V 60 Hz, CWI V,
235 - 230 V 50 Hz
C6 - 480 V 60 Hz, CWI V
TT - 120/277/347 V 60 Hz, CWA V
48 - 480 V 60 Hz
➍ Add -Z2 suffix for factory sealed non-sparking/restricted breathing protection (AEx nA nR). Add -ZB suffix for restricted breathing protection (AEx nR).
➎ For fixtures with guards, add letter G before adding voltage designation.
V CSA Certification only.
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
953
Mercmaster™ III HID 50-250 Watt Luminaires
70 W, 100 W, 150 W, 175 W, 200 W, 250 W PSMH
High Reactance, High Power Factor (min. P.F. 90%). Heat-Resistant Prismatic Glass Globe or Closed Prismatic Glass Refractor. Mogul Base Lamps.
Class I, Division 2, Groups A, B, C, D
Class I, Zone 2, AEx nA nR IIC (Z2)
Class I, Zone 2, Ex nR IIC (Z) V
Class I, Zone 2, AEx nR IIC (ZB)
Class II, Division 1 and 2, Groups E, F, G
Class III
Simultaneous Exposure (Class I, Division 2/
Class II, Division 1)
Lighting: Enclosed and Gasketed — Area — HID
Lighting
Lamp Type
Wall — Five Hubs, Four Close-Up Plugs
Lamp Watts
PSMH
70
PSMH
100
PSMH
150
PSMH
175
PSMH
200
PSMH
250 ➏
PSMH
70
PSMH
100
PSMH
150
PSMH
175
PSMH
200
PSMH
250 ➏
PSMH
70
PSMH
100
PSMH
150
PSMH
175
PSMH
200
PSMH
250 ➏
25° Stanchion — One Hub
Hub Size
(Inches)
Fixtures Outside Type (Salt Water)
Type 4X
IP66
Catalog Numbers ➌➍➎
with Globe
with Type V 8” Refractor ➋
3/4
1
3/4
1
3/4
1
3/4
1
3/4
1
3/4
1
KPWBH7075
KPWBH7010
KPWBH1075
KPWBH1010
KPWBP1575
KPWBP1510
KPWBP1775
KPWBP1710
KPWBP2075
KPWBP2010
KPWBP2575
KPWBP2510
KPWBH7075J5
KPWBH7010J5
KPWBH1075J5
KPWBH1010J5
KPWBP1575J5
KPWBP1510J5
KPWBP1775J5
KPWBP1710J5
KPWBP2075J5
KPWBP2010J5
KPWBP2575J5
KPWBP2510J5
1-1/4
1-1/2
1-1/4
1-1/2
1-1/4
1-1/2
1-1/4
1-1/2
1-1/4
1-1/2
1-1/4
1-1/2
KPSH70125
KPSH70150
KPSH10125
KPSH10150
KPSP15125
KPSP15150
KPSP17125
KPSP17150
KPSP20125
KPSP20150
KPSP25125
KPSP25150
KPSH70125J5
KPSH70150J5
KPSH10125J5
KPSH10150J5
KPSP15125J5
KPSP15150J5
KPSP17125J5
KPSP17150J5
KPSP20125J5
KPSP20150J5
KPSP25125J5
KPSP25150J5
1-1/4
1-1/2
1-1/4
1-1/2
1-1/4
1-1/2
1-1/4
1-1/2
1-1/4
1-1/2
1-1/4
1-1/2
KPSTH70125
KPSTH70150
KPSTH10125
KPSTH10150
KPSTP15125
KPSTP15150
KPSTP17125
KPSTP17150
KPSTP20125
KPSTP20150
KPSTP25125
KPSTP25150
KPSTH70125J5
KPSTH70150J5
KPSTH10125J5
KPSTH10150J5
KPSTP15125J5
KPSTP15150J5
KPSTP17125J5
KPSTP17150J5
KPSTP20125J5
KPSTP20150J5
KPSTP25125J5
KPSTP25150J5
90° Stanchion — One Hub
Shown with Globe and Optional Guard
➊ For Flexible Pendant Mount, change A to F in catalog number (except 50 W HPS).
➋ To order fixtures with large globe change J5 to G3; for fixture with NEMA Type I or NEMA Type III refractor, change final digit 5 in catalog number to 1 or 3.
➌ Add the following voltage and frequency designation before Z2 suffix:
Voltage Suffixes
Lamp Type Lamp Watts
MT
5MT
48
125
225
226
235
245
C2 V
C3 V
C6 V
C7 V
TT V
HPS
50
X
—
—
—
X
X
—
X
—
—
—
—
X
HPS
70
X
—
X
X
X
X
—
X
—
—
—
—
X
HPS
100
X
—
X
X
X
X
—
X
—
—
X
X
X
HPS
150
X
—
X
X
X
X
—
X
—
—
X
X
X
PSMH
70
X
—
X
X
X
—
—
X
—
—
—
—
X
PSMH
100
X
—
X
X
X
—
—
X
—
—
—
—
X
PSMH
150
X
—
X
X
X
—
—
X
—
—
—
—
X
PSMH
175
X
X
X
—
—
—
—
—
—
—
—
—
X
PSMH
200
X
—
X
—
—
—
—
—
—
—
—
—
X
PSMH
250
X
—
—
—
—
—
—
—
—
—
—
—
X
175
X
—
—
X
X
—
—
X
X
X
X
X
X
MH V
250
X
—
—
X
X
—
—
X
X
X
X
X
X
MH V
245 - 240 V 50 Hz
Voltages:
125 - 120 V 50 Hz
MT - 120/208/240/277 V 60 Hz
225 - 225 V 50 Hz
C2 - 208 V 60 Hz, CWI V
5MT - 120/208/240/277/480 V 60 Hz
226 - 220 V 60 Hz
C3 - 240 V 60 Hz, CWI V
C7 - 600 V 60 Hz, CWI V,
48 - 480 V 60 Hz
235 - 230 V 50 Hz
C6 - 480 V 60 Hz, CWI V
TT - 120/277/347 V 60 Hz, CWA V
➍ Add -Z2 suffix for factory sealed non-sparking/restricted breathing protection (AEx nA nR). Add -ZB suffix for restricted breathing protection (AEx nR).
➎ For fixtures with guards, add letter G before adding voltage designation.
V CSA Certification only.
954
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
Mercmaster™ III HID 50-250 Watt
175 W, 250 W MH V
High Reactance, High Power Factor (min. P.F. 90%). Heat-Resistant Prismatic Glass Globe or Closed Prismatic Glass Refractor. Mogul Base Lamps
Class I, Division 2, Groups A, B, C, D
Class I, Zone 2, AEx nA nR IIC (Z2)
Class I, Zone 2, Ex nR IIC (Z) V
Class I, Zone 2, AEx nR IIC (ZB)
Class II, Division 1 and 2, Groups E, F, G
Class III
Simultaneous Exposure (Class I, Division 2/
Class II, Division 1)
Lamp Type
Lamp Watts
Hub Size
(Inches)
Fixtures Outside Type (Salt Water)
Type 4X
IP66
Catalog Numbers ➌➍➎
with Globe
with Type V 8” Refractor ➋
Pendant — One Hub, Rigid Mounting ➊
175
MH V
250 ➏
KPAH1775
KPAH1775J5
1
KPAH1710
KPAH1710J5
3/4
KPAH2575
KPAH2575J5
1
KPAH2510
KPAH2510J5
3/4
KPCHH1775
KPCHH1775J5
1
KPCHH1710
KPCHH1710J5
3/4
KPCHH2575
KPCHH2575J5
1
KPCHH2510
KPCHH2510J5
3/4
KPCH1775
KPCH1775J5
1
KPCH1710
KPCH1710J5
3/4
KPCH2575
KPCH2575J5
1
KPCH2510
KPCH2510J5
Lighting: Enclosed and Gasketed — Area — HID
3/4
Lighting
MH V
Pendant Cone — One Hub, Rigid Mounting
MH V
175
MH V
250 ➏
Ceiling — Five Hubs, Four Close-Up Plugs
MH V
175
MH V
250 ➏
➊ For Flexible Pendant Mount, change A to F in catalog number (except 50 W HPS).
➋ To order fixtures with large globe change J5 to G3; for fixture with NEMA Type I or NEMA Type III refractor, change final digit 5 in catalog number to 1 or 3.
➌ Add the following voltage and frequency designation before Z2 suffix:
Voltage Suffixes
Lamp Type Lamp Watts
MT
5MT
48
125
225
226
235
245
C2 V
C3 V
C6 V
C7 V
TT V
HPS
50
X
—
—
—
X
X
—
X
—
—
—
—
X
HPS
70
X
—
X
X
X
X
—
X
—
—
—
—
X
HPS
100
X
—
X
X
X
X
—
X
—
—
X
X
X
HPS
150
X
—
X
X
X
X
—
X
—
—
X
X
X
PSMH
70
X
—
X
X
X
—
—
X
—
—
—
—
X
PSMH
100
X
—
X
X
X
—
—
X
—
—
—
—
X
PSMH
150
X
—
X
X
X
—
—
X
—
—
—
—
X
PSMH
175
X
X
X
—
—
—
—
—
—
—
—
—
X
PSMH
200
X
—
X
—
—
—
—
—
—
—
—
—
X
PSMH
250
X
—
—
—
—
—
—
—
—
—
—
—
X
175
X
—
—
X
X
—
—
X
X
X
X
X
X
MH V
250
X
—
—
X
X
—
—
X
X
X
X
X
X
MH V
245 - 240 V 50 Hz
Voltages:
125 - 120 V 50 Hz
MT - 120/208/240/277 V 60 Hz
225 - 225 V 50 Hz
C2 - 208 V 60 Hz, CWI V
5MT - 120/208/240/277/480 V 60 Hz
226 - 220 V 60 Hz
C3 - 240 V 60 Hz, CWI V
C7 - 600 V 60 Hz, CWI V,
48 - 480 V 60 Hz
235 - 230 V 50 Hz
C6 - 480 V 60 Hz, CWI V
TT - 120/277/347 V 60 Hz, CWA V
➍ Add -Z2 suffix for factory sealed non-sparking/restricted breathing protection (AEx nA nR). Add -ZB suffix for restricted breathing protection (AEx nR).
➎ For fixtures with guards, add letter G before adding voltage designation.
V CSA Certification only.
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
955
Mercmaster™ III HID 50-250 Watt
175 W, 250 W MH V
High Reactance, High Power Factor (min. P.F. 90%). Heat-Resistant Prismatic Glass Globe or Closed Prismatic Glass Refractor. Mogul Base Lamps
Class I, Division 2, Groups A, B, C, D
Class I, Zone 2, AEx nA nR IIC (Z2)
Class I, Zone 2, Ex nR IIC (Z) V
Class I, Zone 2, AEx nR IIC (ZB)
Class II, Division 1 and 2, Groups E, F, G
Class III
Simultaneous Exposure (Class I, Division 2/
Class II, Division 1)
Lighting: Enclosed and Gasketed — Area — HID
Lighting
Lamp Type
Wall — Five Hubs, Four Close-Up Plugs
MH V
Lamp Watts
175
MH V
250 ➏
MH V
175
Hub Size
(Inches)
Fixtures Outside Type (Salt Water)
Type 4X
IP66
Catalog Numbers ➌➍➎
with Globe
with Type V 8” Refractor ➋
KPWBH1775
3/4
KPWBH1775J5
1
KPWBH1710
KPWBH1710J5
3/4
KPWBH2575
KPWBH2575J5
1
KPWBH2510
KPWBH2510J5
1-1/4
KPSH17125
KPSH17125J5
1-1/2
KPSH17150
KPSH17150J5
1-1/4
KPSH25125
KPSH25125J5
1-1/2
KPSH25150
KPSH25150J5
1-1/4
KPSTH17125
KPSTH17125J5
1-1/2
KPSTH17150
KPSTH17150J5
1-1/4
KPSTH25125
KPSTH25125J5
1-1/2
KPSTH25150
KPSTH25150J5
25° Stanchion — One Hub
MH V
250 ➏
MH V
175
MH V
250 ➏
90° Stanchion — One Hub
Shown with Globe and Optional Guard
➊ For Flexible Pendant Mount, change A to F in catalog number (except 50 W HPS).
➋ To order fixtures with large globe change J5 to G3; for fixture with NEMA Type I or NEMA Type III refractor, change final digit 5 in catalog number to 1 or 3.
➌ Add the following voltage and frequency designation before Z2 suffix:
Voltage Suffixes
Lamp Type Lamp Watts
MT
5MT
48
125
225
226
235
245
C2 V
C3 V
C6 V
C7 V
TT V
HPS
50
X
—
—
—
X
X
—
X
—
—
—
—
X
HPS
70
X
—
X
X
X
X
—
X
—
—
—
—
X
HPS
100
X
—
X
X
X
X
—
X
—
—
X
X
X
HPS
150
X
—
X
X
X
X
—
X
—
—
X
X
X
PSMH
70
X
—
X
X
X
—
—
X
—
—
—
—
X
PSMH
100
X
—
X
X
X
—
—
X
—
—
—
—
X
PSMH
150
X
—
X
X
X
—
—
X
—
—
—
—
X
PSMH
175
X
X
X
—
—
—
—
—
—
—
—
—
X
PSMH
200
X
—
X
—
—
—
—
—
—
—
—
—
X
PSMH
250
X
—
—
—
—
—
—
—
—
—
—
—
X
175
X
—
—
X
X
—
—
X
X
X
X
X
X
MH V
250
X
—
—
X
X
—
—
X
X
X
X
X
X
MH V
245 - 240 V 50 Hz
Voltages:
125 - 120 V 50 Hz
MT - 120/208/240/277 V 60 Hz
225 - 225 V 50 Hz
C2 - 208 V 60 Hz, CWI V
5MT - 120/208/240/277/480 V 60 Hz
226 - 220 V 60 Hz
C3 - 240 V 60 Hz, CWI V
C7 - 600 V 60 Hz, CWI V,
48 - 480 V 60 Hz
235 - 230 V 50 Hz
C6 - 480 V 60 Hz, CWI V
TT - 120/277/347 V 60 Hz, CWA V
➍ Add -Z2 suffix for factory sealed non-sparking/restricted breathing protection (AEx nA nR). Add -ZB suffix for restricted breathing protection (AEx nR).
➎ For fixtures with guards, add letter G before adding voltage designation.
V CSA Certification only.
956
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
Mercmaster™ III HID 50-250 Watt PRE-PAK™ Luminaires
Factory-Assembled Fixtures
For 70 W, 100 W or 150 W High Pressure Sodium Lamps, or 100 W or 175 W Pulse Start Metal Halide Lamps. Mogul Base Lamps.
Class I, Division 2, Groups A, B, C, D
Class I, Zone 2, AEx nA nR IIC (Z2)
Class I, Zone 2, Ex nR IIC (Z) V
Class I, Zone 2, AEx nR IIC (ZB)
Class II, Division 1 and 2, Groups E, F, G
Class III
Simultaneous Exposure (Class I, Division 2/
Class II, Division 1)
Fixtures Outside Type (Salt Water)
Type 4X
IP66
These pre-packaged fixture component combinations are delivered fully assembled and packed in a single carton. They are available with
or without lamp, and with choice of globe or NEMA Type I, III or V refractors – all with or without guards. PRE-PAK units simplify ordering,
stocking and shipping, and result in savings on job-site assembly and installation time and costs.
Lighting
Catalog numbers do not include mounting hood or reflector. For mounting hood and reflectors selection, see below and order
separately. Hood and Reflector will be packaged separately.
Lamp Type
and Watts
100 W PSMH ➋
175 W PSMH
70 W HPS
100 W HPS
150 W HPS
175 W MH V
Ballast Assembly
with Globe Only
KPBU100H-MT
KPBU175P-MT
KPBU70L-MT
KPBU100L-MT
KPBU150L-MT
KPBU175H-TT
Ballast Assembly
with Globe and Guard
KPBU100HG-MT
KPBU175PG-MT
KPBU70LG-MT
KPBU100LG-MT
KPBU150LG-MT
KPBU175HG-TT
250 W MH V
KPBU250H-TT
KPBU250HG-TT
Ballast Assembly
with G3 Globe Only
—
—
—
KPBUG3100L-MT
—
—
—
Pendant
One Hub, Rigid Mounting
Hub Size
Catalog
(Inches)
Number
3/4
KPA-75
1
KPA-100
Pendant — Flexible
One Hub, Flexible Mounting
3/4
KPAF-75
1
KPAF-100
Pendant Cone
One Hub, Rigid
3/4
KPCH-75
1
KPCH-100
Ceiling
Five Hubs,
Four Close-Up Plugs
Wall
Five Hubs,
Four Close-Up Plugs
3/4
KPC-75
1
KPC-100
3/4
KPWB-75
1
KPWB-100
25° Stanchion
One Hub
90° Stanchion
One Hub
Ballast Assembly
with Refractor and Guard
KPBU100HJ5G-MT
KPBU175PJ5G-MT
KPBU70LJ5G-MT
KPBU100LJ5G-MT
KPBU150LJ5G-MT
KPBU175HJ5G-TT
KPBU250HJ5-TT
KPBU250HJ5G-TT
White Polyester Reflectors
Furnished with stainless steel screws
Mounting Hoods
Description
Ballast Assembly
with Refractor Only ➌
KPBU100HJ5-MT
KPBU175PJ5-MT
KPBU70LJ5-MT
KPBU100LJ5-MT
KPBU150LJ5-MT
KPBU175HJ5-TT
1-1/4
KPS-125
1-1/2
KPS-150
1-1/4
KPST-125
1-1/2
KPST-150
Description
Catalog
Number
Standard Dome
For Globe Fixtures
KR2-ST
30° Angle
For Globe Fixtures
KR2-AN
Standard Dome
For Glass Refractor Fixtures
CMR-4ST
30° Angle
For Glass Refractor Fixtures
CMR-4AN
➊ All catalog numbers above are fixtures without lamp. To order fixture complete with appropriate installed lamp, add suffix L to catalog number. All PRE-PAK fixtures
include multi-tap ballast for operation on 120 V, 208 V, 240 V or 277 V lines. Fixture component combinations listed are furnished completely assembled in a single
carton.
➋ 100 W fixtures use ED-28 mogul base lamps.
➌ Refractor catalog numbers listed are for NEMA Type V. To order fixture with Type III refractor, change J5 in catalog number to J3; for Type I refractor, change
J5 to J1.
➍ For CSA 120/277/347 Vac tri-tap ballast, change -MT to -TT V.
V CSA Certification only.
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
957
Lighting: Enclosed and Gasketed — Area — HID
PRE-PAK Fixtures ➊➍
Mercmaster™ III HID 50-250 Watt Luminaire Mounting Hoods
High Pressure Sodium and Pulse Start Metal Halide
Listed for simultaneous exposure to combustible dusts and flammable gases or vapors.
Mounting Hoods
Description
Hub Size (Inches)
Catalog Number
Lighting
Pendant
One Hub, Rigid Mounting
3/4
KPA-75
1
KPA-100
3/4
KPAF-75
1
KPAF-100
3/4
KPCH-75
1
KPCH-100
Pendant — Flexible
Lighting: Enclosed and Gasketed — Area — HID
One Hub, Flexible Mounting
Pendant Cone
One Hub, Rigid
Ceiling
Five Hubs, Four Close-Up Plugs
3/4
KPC-75
1
KPC-100
3/4
KPWB-75
1
KPWB-100
Wall
Five Hubs, Four Close-Up Plugs
25° Stanchion
One Hub
1-1/4
KPS-125
1-1/2
KPS-150
1-1/4
KPST-125
1-1/2
KPST-150
90° Stanchion
One Hub
958
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
Mercmaster™ III HID 50-250 Watt Luminaire Ballast Bodies
High Pressure Sodium and Pulse Start Metal Halide
Listed for simultaneous exposure to combustible dusts and flammable gases or vapors.
Class I, Division 2, Groups A, B, C, D
Class I, Zone 2, AEx nA nR IIC (Z2)
Class I, Zone 2, Ex nR IIC (Z) V
Class I, Zone 2, AEx nR IIC (ZB)
Class II, Division 1 and 2, Groups E, F, G
Class III
Simultaneous Exposure (Class I, Division 2/
Class II, Division 1)
Fixtures Outside Type (Salt Water)
Type 4X
IP66
Ballast Bodies
Ballast Body for Glass Refractor or G3 Globe (shown)
High Pressure Sodium
High Power Factor (Min. P.F. 90%)
Pulse Start Metal Halide
Super Constant Wattage Autotransformer (Min. P.F. 90%)
Catalog Number ➋➍➎➏
Lamp
Watts
HPS
For Globe
For G3 Globe ➊/
Refractor
Voltage Suffixes
MT
5MT
48
125
225
226
235
245
C2 V C3 V C6 V C7 V TT V
50 ➌
KPB50L
KPBR50L
X
—
—
—
X
X
—
X
—
—
—
—
X
HPS
70 ➌
KPB70L
KPBR70L
X
—
X
X
X
X
—
X
—
—
—
—
X
HPS
100 ➌
KPB100L
KPBR100L
X
—
X
X
X
X
—
X
—
—
X
X
X
HPS
150 ➌
KPB150L
KPBR150L
X
—
X
X
X
X
—
X
—
—
X
X
X
PSMH
70
KPB70H
KPBR70H
X
—
X
X
X
—
—
X
—
—
—
—
X
PSMH
100
KPB100H
KPBR100H
X
—
X
X
X
—
—
X
—
—
—
—
X
PSMH
150
KPB150P
KPBR150P
X
—
X
X
X
—
—
X
—
—
—
—
X
PSMH
175
KPB175P
KPBR175P
X
X
X
—
—
—
—
—
—
—
—
—
X
PSMH
200
KPB200P
KPBR200P
X
—
X
—
—
—
—
—
—
—
—
—
X
PSMH
250
KPBG250P
KPBR250P
X
—
—
—
—
—
—
—
—
—
—
—
X
MH V
175
KPB175H
KPBR175H
X
—
—
X
X
—
—
X
X
X
X
X
X
MH V
250
KPB250H
KPBR250H
X
—
—
X
X
—
—
X
X
X
X
X
X
Voltages:
LB - Incandescent, 120 V 60 Hz
MT - 120/208/240/277 V 60 Hz
5MT - 120/208/240/277/480 V 60 Hz
48 - 480 V 60 Hz
125 - 120 V 50 Hz
225 - 225 V 50 Hz
226 - 220 V 60 Hz
235 - 230 V 50 Hz
245 - 240 V 50 Hz
C2 - 208 V 60 Hz, CWI V
C3 - 240 V 60 Hz, CWI V
C6 - 480 V 60 Hz, CWI V
C7 - 600 V 60 Hz, CWI V,
TT - 120/277/347 V 60 Hz, CWA V
➊ For HPS version fixtures only.
➋ After voltage suffix add: -S for Smart Starter.
➌ After voltage suffix add: -SR for Smart Hot Restrike, -R for ballast body with Hot Restrike Ignitor.
➍ Add -E after voltage suffix for ballast body with provision for Quartz Emergency Light. Not suitable for hazardous locations.
➎ Add Z2 suffix for factory sealed non-sparking/restricted breathing protection (AEx nA nR). Add ZB suffix for restricted breathing protection (AEx nR).
➏ Add Z for factory sealed restricted breathing protection (Ex nR) V.
V CSA Certification only.
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
959
Lighting: Enclosed and Gasketed — Area — HID
Lamp
Type
Lighting
Ballast Body for Glass Globe (shown)
Mercmaster™ III HID 50-250 Watt Luminaire Optics
High Pressure Sodium and Pulse Start Metal Halide
Listed for simultaneous exposure to combustible dusts and flammable gases or vapors.
Description
Catalog Number
Prismatic Glass Globes — Heat-Resistant
Lighting
For use in areas where fixture is subject to
extreme thermal shock
Heat-Resistant
Clear
VPGL-2HR
Amber
VPGL-2AM
Blue
VPGL-2BL
Green
VPGL-2GR
Red
VPGL-2RE
Clear
VPGL3HR
Clear
VPGL-2HRT
Clear
VPGL-2PL
Amber
VPGL-2AMPL
Green
VPGL-2GRPL
Red
VPGL-2REPL
Lighting: Enclosed and Gasketed — Area — HID
Glass Globe
G3 Glass Globe
Tuff-Skin® Coated Prismatic Glass Globes — For Non-Classified Areas
For use in areas where fixture is subject to
extreme thermal shock
Heat-Resistant
Tuff-Skin® Glass Globe
Polycarbonate Globes — Impact-Resistant ➊
Use 100 watt lamp max. Do not use in
ambients exceeding 77 ºF/25 ºC.
Polycarbonate Globe
➊ Polycarbonate globes are shatter-resistant – for use in processing plants, canneries, dairies, bakeries or anywhere broken glass would prove a hazard. Ideally
suited for areas where vandalism, high replacement and high maintenance costs are a problem. Do not use in ambients exceeding 77 °F/25 °C. For burning in
vertical base-up positions only.
960
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
Mercmaster™ III HID 50-250 Watt Luminaire Optics
High Pressure Sodium and Pulse Start Metal Halide
Listed for simultaneous exposure to combustible dusts and flammable gases or vapors.
Light Distribution
IES/NEMA Distribution Curves
Catalog Number
Closed Prismatic Glass Refractors — Heat-Resistant
NEMA Type III
LPG-R3
NEMA Type V
LPG-R5
Closed Prismatic Polymeric Refractors
For use with PSMH lamps, 100 W max. 104 °F/40 °C max. ambient temperature.
Suitable for Class II, Division 1 and 2, Groups F, G; NEMA 4X, UL 1598A Marine Type Electric Fixtures Outside Type (Salt Water)
NEMA Type II
LPRF-2CP
NEMA Type III
LPRF-3CP
NEMA Type IV
LPRF-4CP
NEMA Type V
LPRF-5CP
Polymeric Refractor
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
961
Lighting: Enclosed and Gasketed — Area — HID
LPG-R1
Lighting
Glass Refractor
NEMA Type I
Mercmaster™ III HID 50-250 Watt Luminaire Accessories and Replacement Parts
High Pressure Sodium and Pulse Start Metal Halide
Listed for simultaneous exposure to combustible dusts and flammable gases or vapors.
Item
Description
Catalog Number
White Polyester Reflectors — Furnished with stainless steel screws
Lighting
For Globe Fixtures
Lighting: Enclosed and Gasketed — Area — HID
For Glass Refractor Fixtures ➋
Standard Dome
Standard Dome
KR2-ST
Deep Dome
KR2-DD ➊
30° Angle
KR2-AN
Standard Dome
CMR-4ST
Deep Dome
CMR-4DD ➊
30° Angle
CMR-4AN
Globe Guard
KGU2
G3 Globe/Refractor
Guard
KRG2
Globe Gasket
VPGL-GK
G3 Globe/Refractor
Gasket
KRF-GK
30° Angle
Guards
Globe Guard
Refractor Guard
Replacement Globe Gaskets — Silicone Rubber
Globe Gaskets
Retrofit Pendant Mounting Adapter
Permits use of Mercmaster III pendant hood
with 3/4” hub on existing V-51 mounting
hood.
LPAD-1
Mounting Adapter
➊ Dark Skies Compliant.
➋ Fixtures with refractors are not UL Listed when used with reflectors.
962
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
Mercmaster™ III HID 50-250 Watt Luminaire Ballast Weights and Fuse Kits
High Pressure Sodium and Pulse Start Metal Halide
Listed for simultaneous exposure to combustible dusts and flammable gases or vapors.
Class I, Division 2, Groups A, B, C, D
Class I, Zone 2, AEx nA nR IIC (Z2)
Class I, Zone 2, Ex nR IIC (Z) V
Class I, Zone 2, AEx nR IIC (ZB)
Class II, Division 1 and 2, Groups E, F, G
Class III
Simultaneous Exposure (Class I, Division 2/
Class II, Division 1)
Ballast Housing Weights
Fuse Kits
PSMH
(Wt. Lbs/Kg ➊➋)
—
15.75/7.1
16.75/7.6
17.25/7.8
17.75/8.1
18.5/8.4
19/8.6
Wt. Lbs/Kg ➊
2.25/1.0
2.5/1.1
3/1.4
4/1.8
3.25/1.5
3.75/1.7
5.25/2.4
3.75/1.7
1/0.5
1/0.5
Standard Dome
2.50/1.1
30° Angle
2.50/1.1
240
2
F5
—
277
347 V
480
120
208
240
277
1
1
2
1
2
2
1
1
2
1
2
2
1
F5
F2
F3
—
—
—
—
F2
—
—
—
—
—
—
F2
—
F5
F3
F3
F2
F2
F2
F9
F6
F5
F4
347 V
480
120
208
240
277
1
—
F2
2
1
2
2
1
—
—
—
—
—
F2
F8
F5
F5
F3
347 V
1
F3
F3
347 V
120
208
240
277
70
Component and Accessory Weights
Item
Mounting Hoods
Pendant
Pendant Cone
Ceiling
Wall
25° Stanchion
Straight Stanchion
Refractors, Globes and Guards
8” Glass Refractor/G3 Globe
Glass Globe
Globe Guard
Refractor Guard
Reflectors
347 V
480
120
208
Volts
120
208
240
277
50
100
347 V
480
120
208
240
277
150
347 V
480
120
208
240
277
175
200
250
Fuse Kit Catalog Number
Fuse Quantity
Required
1
2
2
1
1
1
2
2
1
1
2
1
2
2
1
1
2
1
2
HPS
F5
F3
F3
F2
F1
F5
F3
F3
F2
F1
F2
F8
F5
F5
F3
F1
F3
F10
F5
PSMH
—
—
—
—
F1
F4
F3
F3
F2
F2
F1
F6
F4
F3
F3
F2
F2
—
—
➊ Weights are approximate.
➋ Add 1 lbs/0.5 kg for HPS fixtures with Hot Restrike. Add 0.25 lbs/0.1 kg for Quartz Emergency Light.
V CSA Certification only.
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
963
Lighting: Enclosed and Gasketed — Area — HID
—
15.25/6.9
16.25/7.4
16.75/7.6
17.25/7.8
18/8.2
18.5/8.4
Lamp
Watts
Lighting
HPS
Lamp Watts
(Wt. Lbs/Kg ➊➋)
Globe Housing with Ballast
50
12.5/5.7
70
15/6.8
100
16/7.3
150
17/7.7
175
—
200
—
250
—
Refractor Housing with Ballast
50
13/5.9
70
15.5/7.0
100
16.5/7.5
150
17.5/7.9
175
—
200
—
250
—
Fixtures Outside Type (Salt Water)
Type 4X
IP66
Mercmaster™ III HID 50-250 Watt Luminaire Electrical Specifications
High Pressure Sodium and Pulse Start Metal Halide
Listed for simultaneous exposure to combustible dusts and flammable gases or vapors.
Class I, Division 2, Groups A, B, C, D
Class I, Zone 2, AEx nA nR IIC (Z2)
Class I, Zone 2, Ex nR IIC (Z) V
Class I, Zone 2, AEx nR IIC (ZB)
Class II, Division 1 and 2, Groups E, F, G
Class III
Simultaneous Exposure (Class I, Division 2/
Class II, Division 1)
Fixtures Outside Type (Salt Water)
Type 4X
IP66
Lighting: Enclosed and Gasketed — Area — HID
Lighting
Electrical Specifications
Line
Type of
Starting
Voltage
Ballast ➊
Amps
50 Watt High Pressure Sodium
120
HX-HPF
0.58
208
HX-HPF
0.35
240
HX-HPF
0.31
277
HX-HPF
0.25
HX-HPF
0.26
347 V
70 Watt High Pressure Sodium
120
HX-HPF
0.90
208
HX-HPF
0.50
240
HX-HPF
0.44
277
HX-HPF
0.35
HX-HPF
0.30
347 V
480
HX-HPF
0.21
100 Watt High Pressure Sodium
120
HX-HPF
1.30
208
HX-HPF
0.76
240
HX-HPF
0.66
277
HX-HPF
0.60
HX-HPF
0.45
347 V
480
HX-HPF
0.33
480
C.W.I.
0.17
600
C.W.I.
0.14
150 Watt High Pressure Sodium ➋
120
HX-HPF
2.00
208
HX-HPF
1.15
240
HX-HPF
1.00
277
HX-HPF
0.85
HX-HPF
0.52
347 V
480
HX-HPF
0.50
480
C.W.I.
0.25
600
C.W.I.
0.19
70 Watt Pulse Start Metal Halide
120
HX-HPF
0.80
208
HX-HPF
0.50
240
HX-HPF
0.43
277
HX-HPF
0.39
HX-HPF
0.20
347 V
480
HX-HPF
0.26
100 Watt Pulse Start Metal Halide
120
HX-HPF
1.20
208
HX-HPF
0.70
240
HX-HPF
0.61
277
HX-HPF
0.55
HX-HPF
0.40
347 V
480
HX-HPF
0.30
Operating
Amps
Total
Watts
0.58
0.33
0.29
0.25
0.21
64
64
64
64
68
0.82
0.48
0.41
0.36
0.30
0.21
94
94
94
94
94
94
1.15
0.67
0.60
0.52
0.39
0.31
0.30
0.24
130
130
130
130
130
135
130
130
1.70
0.95
0.85
0.72
0.56
0.47
0.42
0.35
188
188
188
188
188
189
190
190
0.85
0.52
0.44
0.39
0.28
0.23
95
95
95
95
88
95
1.15
0.70
0.58
0.50
0.40
0.35
130
130
130
130
129
140
Line
Type of
Starting
Voltage
Ballast ➊
Amps
150 Watt Pulse Start Metal Halide
120
HX-HPF
1.75
208
HX-HPF
1.30
240
HX-HPF
0.85
277
HX-HPF
0.77
Super C.W.A.
0.65
347 V
480
Super C.W.A.
0.45
175 Watt Pulse Start Metal Halide
120
Super C.W.A.
0.90
208
Super C.W.A.
0.50
240
Super C.W.A.
0.35
277
Super C.W.A.
0.30
Super C.W.A.
0.25
347 V
480
Super C.W.A.
0.25
Operating
Amps
Total
Watts
1.60
1.00
0.80
0.70
0.55
0.42
188
188
188
188
185
185
1.78
1.08
0.89
0.76
0.65
0.50
199
199
199
199
208
213
175 Watt Metal Halide V
120
C.W.A.
208
C.W.A.
240
C.W.A.
277
C.W.A.
347
C.W.A.
480
C.W.I.
600
C.W.I.
1.30
0.75
0.65
0.55
0.50
0.20
0.16
1.80
1.04
0.90
0.80
0.65
0.45
0.37
210
210
210
210
210
215
215
175 Watt Metal Halide V
120
Super C.W.A.
208
Super C.W.A.
240
Super C.W.A.
277
Super C.W.A.
480
Super C.W.A.
1.30
0.75
0.65
0.55
0.35
1.80
1.10
0.90
0.80
0.45
213
213
213
213
213
250 Watt Metal Halide V
120
Super C.W.A.
208
Super C.W.A.
240
Super C.W.A.
277
Super C.W.A.
480
Super C.W.A.
1.20
0.65
0.60
0.50
0.30
2.60
1.50
1.30
1.12
0.65
298
298
298
298
298
➊ C.W.A. – Constant Wattage Autotransformer. HX-HPF – High Reactance High Power Factor Autotransformer. Super C.W.A. – Super Constant Wattage Autotransformer.
➋ 150 W HPS units equipped with ballasts to operate 55 volt lamps only.
V CSA Certification only.
964
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
Mercmaster™ III HID 50-250 Watt Luminaire Dimensions
High Pressure Sodium and Pulse Start Metal Halide
Listed for simultaneous exposure to combustible dusts and flammable gases or vapors.
Ceiling
Pendant
(Rigid or Flex)
13.62”/345.9mm
1.17”/
29.7mm
12.06”/306.3mm
12.06”/306.3mm
1.75”/
44.5mm
Lighting
12.06”/306.3mm
Cone
5.59”/
142.0mm
5.87”/
149.1mm
5.87”/
149.1mm
11.00”/279.4mm
11.00”/279.4mm
11.00”/279.4mm
Wall
17.06”/433.3mm
Globe/Guard/Refractor
1.94”/49.3mm
2.62”/66.5mm
5.87”/
149.1mm
2.75”/69.9mm
6.00”/152.4mm
9.00”/228.6mm
6.50”/
165.1mm
8.00”/
203.2mm
11.00”/279.4mm
17.23”/437.6mm
4.75”/
9.79”/248.7mm
120.7mm
10.17”/
258.3mm
1.87”/47.5mm
15.07”/382.8mm
90º Straight Stanchion
4.00”/
101.6mm
5.87”/
0.94”/
149.1mm
23.9mm
1.94”/49.3mm
16.90”/429.3mm
14.90”/
378.5mm
5.87”/
149.1mm
11.00”/279.4mm
Polymeric Refractor
1.94”/
49.3mm
14.94”/379.5mm
6.06”/
153.9mm
11.00”/279.4mm
5.87”/149.1mm
5.50”/
139.7mm
13.38”/339.9mm
25° Angle Stanchion
6.06”/
153.9mm
8” Globe/Refractor
Body/Guard
13.38”/339.9mm
5.50”/
139.7mm
14.94”/379.5mm
11.00”/279.4mm
5.50”/
139.7mm
1.94”/
49.3mm
5.87”/
149.1mm
5.87”/
149.1mm
11.00”/279.4mm
7.75”/196.9mm
5.87”/149.1mm
7.75”/196.9mm
7.25”/184.2mm
7.78”/199.9mm
11.00”/
11.00”/
279.4mm
10.75”/
273.1mm
7.25”/184.2mm
7.78”/199.9mm
12.38”/
314.5mm
279.4mm
6.69”/
169.9mm
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
6.69”/
169.9mm
965
Lighting: Enclosed and Gasketed — Area — HID
5.87”/
149.1mm
PCD2 Series Factory Sealed Hazardous Location Photocontrol
For use in Class I, Division 2, Groups A, B, C, D locations
Maintains Class I, Division 2 rating for Mercmaster III – Low Profile, Mercmaster III, and Mercmaster III – 400 Series Luminaires, Mercmaster LED
Class I, Division 2, Groups A, B, C, D
NEMA 4X
Lighting
Applications
Materials
• Encapsulated photocontrol provides automatic dusk-to-dawn
lighting control in Class I, Division 2 locations.
• Typical applications include walkways, security areas and any
other outdoor lighting application.
• For use with Mercmaster III – Low Profile, Mercmaster III, and
Mercmaster III – 400 Series Luminaires.
• For remote mounting in FS Boxes.
• Encapsulated with epoxy sealing compound
• FS: aluminum
Certifications and Compliances
• UL Standard: 1604 – Hazardous (Classified) Locations
• cULus Recognized
Lighting: Enclosed and Gasketed — Area — HID
Features
• Factory sealed design eliminates the need for an explosionproof
enclosure.
• Can be easily installed in the field.
• Solid state design for performance and reliability.
• Available for 120, 208, 240, or 277 volts.
• 50-400 W HID incandescent or fluorescent, 50/60 Hz.
• 1000 VA Voltage/Ampere
• Minimum time delay: 15 seconds to eliminate nuisiance tripping.
• Provided with (3) 18AWG stranded leads 6”/152.4mm in length.
• Will fit through standard 1/2” knockout.
Factory-Installed Photocontrol
Dimensions
Add to fixture catalog after voltage; i.e.: KPWBL1075MTH1.
Mercmaster III wall mounting hood
with photocontrol installed shown
Voltage Range
Suffix Designation
120 V, 50/60 Hz
H1
208 V, 50/60 Hz
H2
240 V, 50/60 Hz
H3
277 V, 50/60 Hz
H4
1.13”
28.7
mm
1.13”
28.7 mm
Photocontrol in FS Cover for Use with FS/FD Box
Supplied with two stainless steel screws. For neoprene gasket, order catalog number FS-GKR-1N.
Voltage Range
Catalog Number
120V, 50/60 Hz
FSKA-PC120D2
208-277V, 50/60 Hz
FSKA-PC247D2
1.375”
34.9
mm
1.375”
34.9 mm
2.56”
65.0
mm
2.56”
65.0 mm
1.13”
28.7 mm
Photocontrol for Field Installation
Max. Current
Catalog Number
120 V, 50/60 Hz
Voltage Range
8.3 Amp
PC120D2
208-277 V, 50/60 Hz
3.5 Amp
34.9 mm
PC247D2
2.56”
65.0 mm
966
1.375”
0.69”
17.5 mm
1.19”
30.2 mm
1.94”
49.2 mm
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
Mercmaster™ III HID 50-250 Watt Luminaire Photometric Data
150 W HPS
Listed for simultaneous exposure to combustible dusts and flammable gases or vapors.
* Photometric data is based on fixtures with
150-watt clear High Pressure Sodium lamp
(16,000 lumen).
Zone
Lumens
50.74
10-20
164.55
20-30
310.47
Total Luminaire Efficiency = 86.1%
REPORT NUMBER: KP15LG
Lamps: 150 W High Pressure Sodium with Globe only *
CIE Type – Semi-Direct
Spacing
Criteria
Plane
30-40
611.05
0-180
2.82
Coefficients of Utilization – Zonal Cavity Method
40-50
961.13
90-270
2.82
Effective Floor Cavity Reflectance 0.20
50-60
1308.18
Diagonal
2.80
60-70
1542.35
70-80
1716.10
80-90
1799.18
% Ceiling Rcc
% Walls
70
50
30
10
0
Rw 70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0
0 95 95 95 95 89 89 89 89 77 77 77 67 67 67 57 57 57 53
Lumens % Lamp % Fixture
1 81 74 69 64 75 69 64 59 59 55 51 50 47 44 42 39 37 33
90-100 1802.19
0-30
525.75
3.3
3.8
2 71 62 54 47 65 57 50 44 49 43 38 41 36 32 33 30 27 23
100-110 1676.86
0-40
1136.81
7.1
8.3
3 64 52 44 37 58 48 41 34 41 35 30 34 29 25 28 24 20 17
110-120 1379.11
0-60
3406.12 21.3
24.7
4 57 45 36 30 53 42 34 28 35 29 24 29 24 20 24 19 16 13
120-130 441.46
0-90
8463.75 52.9
61.4
5 52 40 31 24 48 37 29 23 31 24 19 26 20 16 21 16 13 10
130-140
9.61
90-120 4858.16 30.4
35.3
6 48 35 26 20 44 32 25 19 27 21 16 23 17 13 18 14 11
8
140-150
3.33
90-130 5299.62 33.1
38.5
7 44 31 23 17 40 29 21 16 24 18 14 20 15 11 16 12
9
7
150-160
0.74
90-150 5312.56 33.2
38.5
8 40 28 20 15 37 26 19 14 22 16 12 18 13 10 15 11
8
6
160-170
0.00
90-180 5313.30 33.2
38.6
9 38 25 18 13 35 24 17 12 20 14 10 17 12
8 14 10
7
5
170-180
0.00
180-0 13777.05 86.1
100.0
7 13
6
4
Zone
0-10
Lumens
Total Luminaire Efficiency = 73.6%
266.98
CIE Type – Direct
10-20
799.41
20-30
1337.05
9 15 11
9
REPORT NUMBER: KP15LST
Lamps: 150 W High Pressure Sodium with
Standard Dome Reflector *
Spacing
Criteria
Plane
10 35 23 16 11 32 22 15 11 18 13
30-40
1732.06
0-180
1.46
Coefficients of Utilization - Zonal Cavity Method
40-50
2067.60
90-270
1.46
Effective Floor Cavity Reflectance 0.20
50-60
2317.60
Diagonal
1.68
60-70
2210.81
70-80
866.77
80-90
145.09
Lumens % Lamp % Fixture
1 79 76 72 69 77 74 71 68 71 68 66 68 66 64 65 64 62 60
90-100
14.46
0-30
2403.44 15.0
20.4
2 71 65 59 55 69 63 58 54 61 57 53 58 55 52 56 53 50 49
100-110
8.75
0-40
4135.50 25.8
35.1
3 64 56 49 44 62 55 49 44 52 47 43 50 46 42 48 45 41 40
110-120
7.93
0-60
8520.70 53.3
72.3
4 58 49 42 36 57 48 41 36 46 40 36 44 39 35 42 38 35 33
120-130
4.51
0-90
11743.37 73.4
99.7
5 53 43 36 31 52 42 35 30 40 35 30 39 34 30 38 33 29 28
130-140
2.16
90-120
31.14
0.2
0.3
6 49 38 31 26 47 38 31 26 36 30 26 35 30 25 34 29 25 24
140-150
0.48
90-130
35.65
0.2
0.3
7 45 34 27 23 44 34 27 23 33 27 22 31 26 22 30 26 22 20
150-160
0.00
90-150
38.29
0.2
0.3
8 42 31 24 20 40 31 24 20 30 24 20 29 23 19 28 23 19 18
160-170
0.00
90-180
38.29
0.2
0.3
9 39 28 22 18 38 28 22 18 27 21 17 26 21 17 25 21 17 16
170-180
0.00
180-0 11781.65 73.6
100.0
10 36 26 20 16 35 26 20 16 25 19 16 24 19 16 23 19 15 14
% Ceiling Rcc
% Walls
Zonal Lumen Summary
Zone
80
70
50
30
10
0
Rw 70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0
0 88 88 88 88 86 86 86 86 82 82 82 78 78 78 75 75 75 73
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
967
Lighting: Enclosed and Gasketed — Area — HID
Zonal Lumen Summary
Zone
80
Lighting
0-10
For candlepower values of fixtures with other
HPS lamps, use the following multipliers: for
70 W (6,400 lumen) HPS lamp – 0.40; for 50 W
(4,000 lumen) HPS lamp – 0.25. For candlepower
values of fixture with guard, multiply by 0.95.
Mercmaster™ III HID 50-250 Watt Luminaire Photometric Data
150 W HPS
Listed for simultaneous exposure to combustible dusts and flammable gases or vapors.
* Photometric data is based on fixtures with
150-watt clear High Pressure Sodium lamp
(16,000 lumen).
Lighting: Enclosed and Gasketed — Area — HID
Lighting
Zone
Lumens
Total Luminaire Efficiency = 73.1%
0-10
222.62
CIE Type - Direct
10-20
664.6
20-30
1084.32
30-40
1536.55
For candlepower values of fixtures with other
HPS lamps, use the following multipliers: for
70 W (6,400 lumen) HPS lamp – 0.40; for 50 W
(4,000 lumen) HPS lamp – 0.25. For candlepower
values of fixture with guard, multiply by 0.95.
REPORT NUMBER: KP15LAN
Lamps: 150 W High Pressure Sodium with
30° Angle Dome Reflector *
Spacing
Criteria
Plane
0-180
Coefficients of Utilization - Zonal Cavity Method
2.06
40-50
1771.90
90-270
1.58
50-60
1771.51
Diagonal
1.62
60-70
1668.93
70-80
1422.36
80-90
994.54
90-100
432.23
Effective Floor Cavity Reflectance 0.20
% Ceiling Rcc
% Walls
Zonal Lumen Summary
70
50
30
10
0
Rw 70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0
0 86 86 86 86 84 84 84 84 79 79 79 75 75 75 71 71 71 70
Lumens % Lamp % Fixture
1 76 71 67 63 73 69 65 62 65 62 59 62 59 57 58 56 54 52
0-30
1971.54 12.3
16.9
2 68 60 54 49 65 58 53 48 55 50 46 52 48 45 49 46 43 41
100-110 104.58
0-40
3508.09 21.9
30.0
3 61 52 45 39 59 50 44 39 48 42 37 45 40 36 43 39 35 33
110-120
20.99
0-60
7051.50 44.1
60.3
4 55 45 38 32 53 44 37 32 42 36 31 39 34 30 37 33 29 27
120-130
1.21
0-90
11137.33 69.6
95.2
5 50 40 33 27 49 39 32 27 37 31 26 35 30 25 33 29 25 23
130-140
0.04
90-120
557.80
3.5
4.8
6 46 36 28 23 45 35 28 23 33 27 22 31 26 22 30 25 21 20
140-150
0.00
90-130
559.01
3.5
4.8
7 43 32 25 20 41 31 25 20 30 24 19 28 23 19 27 22 19 17
150-160
0.00
90-150
559.04
3.5
4.8
8 40 29 22 18 38 28 22 17 27 21 17 26 21 17 25 20 16 15
160-170
0.00
90-180
559.04
3.5
4.8
9 37 26 20 16 36 26 20 16 25 19 15 24 19 15 23 18 15 13
170-180
0.00
180-0 11696.38 73.1
100.0
10 35 24 18 14 33 24 18 14 23 17 14 22 17 13 21 16 13 12
Zone
Lumens
Zone
80
Total Luminaire Efficiency = 81.1%
REPORT NUMBER: KP15LJR5
Lamps: 150 W High Pressure Sodium with
8” Prismatic Glass Refracter - NEMA Type V *
CIE Type - Semi- Direct
0-10
72.83
10-20
222.26
20-30
380.73
30-40
621.11
0-180
1.98
Coefficients of Utilization - Zonal Cavity Method
40-50
852.53
90-270
1.98
Effective Floor Cavity Reflectance 0.20
50-60
1765.29
Diagonal
3.40
60-70
3192.58
70-80
2366.61
80-90
1230.65
90-100
Spacing
Criteria
Plane
% Ceiling Rcc
% Walls
Zonal Lumen Summary
Zone
80
70
50
30
10
0
Rw 70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0
0 93 93 93 93 89 89 89 89 82 82 82 76 76 76 70 70 70 67
Lumens % Lamp % Fixture
1 80 73 68 63 76 70 65 61 64 60 56 58 55 52 53 50 48 45
450.14
0-30
675.83
4.2
5.2
2 69 59 51 45 65 56 49 43 51 45 40 46 41 37 41 37 34 31
100-110 712.41
0-40
1296.93
8.1
10.0
3 61 49 40 33 57 47 38 32 42 35 29 38 32 27 34 29 25 22
110-120 499.15
0-60
3914.76 24.5
30.2
4 54 42 32 25 51 40 31 24 35 28 22 32 26 21 28 23 19 16
120-130 323.44
0-90
10704.60 66.9
82.5
5 49 36 27 20 46 34 26 19 31 23 18 27 21 16 24 19 15 12
130-140 185.00
90-120 1661.70 10.4
12.8
6 45 32 23 16 42 30 22 16 27 20 14 24 18 13 21 16 12 10
140-150
81.31
90-130 1985.14 12.4
15.3
7 41 28 20 14 38 27 19 13 24 17 12 21 15 11 19 14 10
8
150-160
21.08
90-150 2251.45 14.1
15.3
8 38 25 17 12 36 24 16 11 22 15 10 19 14
6
160-170
2.81
90-180 2275.34 14.2
17.5
170-180
0.00
180-0 12979.94 81.1
100.0
968
9 35 23 15 10 33 22 15 10 20 13
10 33 21 14
9 31 20 13
9 18 12
9 17 12
8
9 18 12
8 16 11
7
5
8 16 11
7 15 10
6
5
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
Mercmaster™ III HID 50-250 Watt Luminaire Photometric Data
175 W PSMH
Listed for simultaneous exposure to combustible dusts and flammable gases or vapors.
* Photometric data is based on fixtures with a
175-watt clear Pulse Start Metal Halide lamp
(17,500 lumen).
Zone
Lumens
57.98
10-20
217.30
20-30
372.71
Total Luminaire Efficiency = 75.4%
REPORT NUMBER: KP17PG
Lamps: 175 W Pulse Start Metal Halide with Globe only *
CIE Type - General Diffuse
Lighting
0-10
For candlepower values of fixtures with other
PSMH lamps, use the following multipliers: for a
100 W (8,500 lumen) PSMH lamp – 0.49; for a 70
W (6,200 lumen) PSMH lamp – 0.36; for a 200 W
(21,000 lumen) PSMH lamp – 1.2. For candlepower
values of fixture with guard, multiply by 0.95.
30-40
696.29
Coefficients of Utilization - Zonal Cavity Method
40-50
1009.65
Effective Floor Cavity Reflectance 0.20
50-60
1226.57
% Ceiling Rcc
60-70
1473.76
% Walls Rw 70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0
70-80
1757.30
80-90
1902.34
Lumens
70
50
30
10
0
0 93 93 93 93 87 87 87 87 75 75 75 64 64 64 54 54 54 50
% Lamp % Fixture
1 79 73 68 63 73 68 63 59 58 54 50 48 45 43 40 37 35 31
90-100 1946.09
0-30
647.99
3.7
4.3
2 70 61 54 47 65 57 50 44 48 42 38 39 35 32 32 29 26 22
100-110 1829.51
0-40
1344.28
7.7
9.0
3 63 52 44 37 58 48 41 35 40 34 29 33 28 24 27 23 20 16
110-120 1657.20
0-60
3580.49
20.5
24.0
4 57 45 37 30 52 42 34 28 35 29 24 29 24 20 23 19 16 12
120-130 750.27
0-90
8713.89
49.8
58.4
5 52 40 31 25 47 37 29 23 31 24 20 25 20 16 20 16 13 10
130-140
14.15
90-120
5432.80
31.0
36.4
6 47 35 27 21 43 32 25 19 27 21 17 22 17 14 18 14 11
8
140-150
4.47
90-130
6183.06
35.3
41.4
7 44 31 23 18 40 29 22 17 24 18 14 20 15 12 16 12
9
7
150-160
0.52
90-150
6201.69
35.4
41.6
8 40 28 21 15 37 26 19 14 22 16 12 18 14 10 15 11
8
6
160-170
1.35
90-180
6203.74
35.4
41.6
9 37 26 18 13 34 24 17 13 20 15 11 17 12
9 13 10
7
5
170-180
0.18
180-0
14917.63
85.2
100.0
8 12
6
4
Zone
0-10
Lumens
Total Luminaire Efficiency = 72.3%
285.95
CIE Type - Direct
10-20
876.46
20-30
1472.88
9 15 11
9
REPORT NUMBER: KP17PST
Lamps: 175 W Pulse Start Metal Halide with
Standard Dome Reflector *
Spacing
Criteria
Plane
10 35 23 16 12 32 22 15 11 18 13
30-40
1924.39
0-180
1.50
Coefficients of Utilization - Zonal Cavity Method
40-50
2213.42
90-270
1.50
Effective Floor Cavity Reflectance 0.20
50-60
2305.55
Diagonal
1.66
60-70
2256.32
70-80
1115.75
80-90
198.05
% Ceiling Rcc
80
70
50
30
10
0
% Walls Rw 70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0
Zonal Lumen Summary
Zone
Lumens
0 86 86 86 86 84 84 84 84 80 80 80 77 77 77 74 74 74 72
% Lamp % Fixture
1 78 74 71 68 76 72 69 67 69 67 65 67 64 63 64 62 61 59
90-100
3.56
0-30
2635.28
15.1
20.8
2 70 63 58 54 68 62 57 53 59 55 52 57 54 50 55 52 49 48
100-110
0.00
0-40
4559.67
26.1
36.0
3 63 55 48 43 61 54 48 43 51 46 42 49 45 41 47 44 41 39
110-120
0.00
0-60
9078.64
51.9
71.8
4 57 48 41 36 56 47 40 35 45 39 35 43 38 34 42 37 34 32
120-130
0.00
0-90
12648.77
72.3
100.0
5 52 42 35 30 51 41 35 30 40 34 30 38 33 29 37 32 29 27
130-140
0.00
90-120
3.56
0.00
0.00
6 48 38 31 26 47 37 30 26 36 30 25 34 29 25 33 29 25 23
140-150
0.00
90-130
3.56
0.00
0.00
7 44 34 27 22 43 33 27 22 32 26 22 31 26 22 30 25 22 20
150-160
0.00
90-150
3.56
0.00
0.00
8 41 31 24 20 40 30 24 20 29 24 19 28 23 19 27 23 19 18
160-170
0.00
90-180
3.56
0.00
0.00
9 38 28 22 18 37 28 22 17 27 21 17 26 21 17 25 21 17 16
170-180
0.00
180-0
12652.33
72.3
100.0
10 36 26 20 16 35 25 20 16 25 19 16 24 19 15 23 19 15 14
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
969
Lighting: Enclosed and Gasketed — Area — HID
Zonal Lumen Summary
Zone
80
Mercmaster™ III HID 50-250 Watt Luminaire Photometric Data
175 W PSMH
Listed for simultaneous exposure to combustible dusts and flammable gases or vapors.
* Photometric data is based on fixtures with a
175-watt clear Pulse Start Metal Halide lamp
(17,500 lumen).
Lighting: Enclosed and Gasketed — Area — HID
Lighting
Zone
For candlepower values of fixtures with other
PSMH lamps, use the following multipliers: for
a 100 W (8,500 lumen) PSMH lamp – 0.49; for 70
W (6,200 lumen) PSMH lamp – 0.36; for a 200 W
(21,000 lumen) PSMH lamp – 1.2. For candlepower
values of fixture with guard, multiply by 0.95.
Lumens
Total Luminaire Efficiency = 67.1%
0-10
240.21
CIE Type - Direct
10-20
750.99
20-30
1195.39
30-40
1662.85
0-180
1.96
40-50
1830.67
90-270
1.70
50-60
1740.13
Diagonal
1.56
60-70
1571.75
70-80
1324.18
80-90
900.65
90-100
367.96
0-30
2186.59
12.5
18.6
2 63 56 51 46 61 55 49 45 52 47 44 49 45 42 46 43 41 39
100-110 107.38
0-40
3849.44
22.0
32.8
3 57 48 42 37 55 47 41 37 45 40 36 42 38 35 40 37 34 32
110-120
27.79
0-60
7420.24
42.4
63.2
4 51 42 36 31 50 41 35 30 39 34 30 37 33 29 35 31 28 26
120-130
5.54
0-90
11216.82
64.1
95.6
5 47 38 31 26 45 37 30 26 35 29 25 33 28 25 32 27 24 22
130-140
4.20
90-120
503.12
2.9
4.3
6 43 34 27 22 42 33 27 22 31 26 22 30 25 21 28 24 21 19
140-150
4.42
90-130
508.66
2.9
4.3
7 40 30 24 20 39 30 24 19 28 23 19 27 22 19 26 22 18 17
150-160
2.00
90-150
517.28
3.0
4.4
8 37 27 21 17 36 27 21 17 26 20 17 25 20 16 24 19 16 15
160-170
1.70
90-180
521.31
3.0
4.4
9 35 25 19 15 33 25 19 15 24 18 15 23 18 15 22 18 14 13
170-180
0.33
180-0 11738.13
67.1
100.0
10 32 23 17 14 31 23 17 14 22 17 13 21 16 13 20 16 13 12
Zone
Lumens
0-10
22.77
10-20
171.20
20-30
325.41
REPORT NUMBER: KP17PAN
Lamps: 175 W Pulse Start Metal Halide with
30° Angle Dome Reflector *
Spacing
Criteria
Plane
Coefficients of Utilization - Zonal Cavity Method
Effective Floor Cavity Reflectance 0.20
% Ceiling Rcc
80
70
50
30
10
0
% Walls Rw 70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0
Zonal Lumen Summary
Zone
Lumens
0 79 79 79 79 77 77 77 77 73 73 73 69 69 69 66 66 66 64
% Lamp % Fixture
1 70 66 62 59 68 64 61 58 60 58 55 57 55 53 54 52 51 49
Total Luminaire Efficiency = 81.1%
REPORT NUMBER: KP17PJR5
Lamps: 175 W Pulse Start Metal Halide with
8” Prismatic Glass Refracter - NEMA Type V *
CIE Type - Semi-Direct
Spacing
Criteria
Plane
30-40
531.35
0-180
1.66
Coefficients of Utilization - Zonal Cavity Method
40-50
1173.62
90-270
1.64
Effective Floor Cavity Reflectance 0.20
50-60
1165.11
Diagonal
1.92
60-70
3171.29
70-80
3719.35
80-90
1751.05
90-100
% Ceiling Rcc
80
70
50
30
10
0
% Walls Rw 70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0
Zonal Lumen Summary
Zone
Lumens
0 94 94 94 94 90 90 90 90 83 83 83 77 77 77 71 71 71 69
% Lamp % Fixture
1 78 71 65 60 74 68 62 57 62 57 53 57 53 49 51 48 46 43
523.23
0-30
519.38
3.0
3.7
2 67 57 48 41 63 54 46 39 49 42 36 44 38 33 39 35 31 28
100-110 716.53
0-40
1050.73
6.0
7.4
3 59 46 37 29 55 44 35 28 40 32 26 35 29 24 32 26 22 19
110-120 431.18
0-60
3389.46
19.4
23.9
4 52 39 30 22 49 37 28 21 33 26 20 30 23 18 26 21 16 14
120-130 265.20
0-90
12031.16
68.7
84.8
5 47 34 24 17 45 32 23 17 29 21 15 26 19 14 23 17 13 10
130-140 142.69
90-120
1670.94
9.5
11.8
6 43 30 21 14 41 28 20 14 25 18 12 23 16 11 20 15 10
8
140-150
57.09
90-130
1936.15
11.1
13.7
7 40 27 18 12 37 23 17 11 23 16 10 20 14
9 18 13
8
6
150-160
13.48
90-150
2135.93
12.2
15.1
8 37 24 16 10 35 23 15 10 20 14
8 16 11
7
5
9 18 12
160-170
2.44
90-180
2152.72
12.3
15.2
9 34 22 14
9 32 21 13
8 19 12
8 17 11
7 15 10
6
4
170-180
0.88
180-0
14183.88
81.1
100.0
10 32 20 12
8 30 19 12
7 17 11
7 16 10
6 14
5
4
970
9
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
Mercmaster™ III HID 50-250 Watt Luminaire Photometric Data
175 W PSMH
Listed for simultaneous exposure to combustible dusts and flammable gases or vapors.
* Photometric data is based on fixtures with a
175-watt clear Pulse Start Metal Halide lamp
(17,500 lumen).
Candela
657
668
784
Lumens
TOTAL LUMINAIRE EFFICIENCY = 70.8%
CIE Type – Semi-Direct
Spacing Criteria: 1.7
65
224
451
1194
705
45
55
65
75
85
90
95
105
115
125
135
145
155
165
175
180
871
1267
1309
1430
1528
1537
1552
1452
1339
68
19
13
7
1
2
7
711
1142
1303
1509
1661
Degree
0
5
15
Candela
2785
2797
2902
Lumens
25
2931
1358
35
2979
1821
45
55
65
75
85
2388
2393
2044
664
150
1874
2145
2034
856
183
90
24
95
105
115
125
135
145
155
165
175
180
5
16
91
5
7
8
2
2
2
11
COEFFICIENTS OF UTILIZATION - ZONAL CAVITY METHOD
ZONAL LUMEN SUMMARY
ZONE LUMENS %LAMP %FIXT.
0-30
740
4.2
6.0
0-40 1445
8.3 11.7
0-60 3297
18.8 26.6
0-90 7770
44.4 62.7
90-120 4444
25.4 35.9
90-130 4586
26.2 37.0
90-150 4613
26.4 37.2
90-180 4617
26.4 37.3
0-180 12387
70.8 100.0
1680
1532
1232
143
16
11
3
1
0
TOTAL LUMINAIRE EFFICIENCY = 65.6%
CIE Type – Direct
Spacing Criteria: 1.5
269
823
90°
950
60°
ZONAL LUMEN SUMMARY
ZONE LUMENS %LAMP %FIXT.
0-30 2450
14.0 21.3
0-40 4271
24.4 37.2
0-60 8290
47.4 72.2
0-90 11363
64.9 99.0
90-120
101
0.6
0.9
90-130
110
0.6
1.0
90-150
115
0.7
1.0
90-180
118
0.7
1.0
0-180 11481
65.6 100.0
11
17
73
9
3
2
2
0
1
45.0
2333
2467
2753
2891
3100
2719
2939
2801
2621
90.0
2333
2321
2337
2480
2544
1993
1791
776
392
135.0
2333
2205
2160
2242
2027
832
421
74
3
85 2729
967
117
5
0 709
662
461
175
8
11
3
5
3
3
5
6
11
3
11
8
13
3
11
5
8
3
6
5
11
19
29
13
3
5
5
5
3
6
5
16 247
21 109
90 56
11
2
0
1
0
4
0
2
0
1
0
0
6
1601
790
413
117
5
0
5
0
5
0
6
EFFECTIVE FLOOR CAVITY REFLECTANCE 0.20
70
50
30
10 70 50 30 10 50 30 10 50 30 10
78 73 73 73 73 64 64 64 56 56 56
53 62 57 53 49 49 46 43 42 39 37
40 54 48 42 37 41 36 32 34 31 27
31 49 40 34 29 34 29 25 29 25 21
25 44 35 29 24 30 25 20 25 21 17
21 40 31 24 20 26 21 17 22 18 14
18 37 27 21 16 23 18 14 20 15 12
15 34 25 18 14 21 16 12 18 13 10
13 31 22 16 12 19 14 11 16 12 9
11 29 20 15 11 17 13 9 15 11 8
10 27 18 13 9 16 11 8 14 10 7
50
48
35
28
24
21
18
16
15
13
12
11
10
30
48
33
26
21
17
15
13
11
10
9
8
10
48
31
23
18
14
12
10
9
7
7
6
0
0
44
28
20
15
12
9
8
7
6
5
4
REPORT NUMBER: KPB175PG3_ST
Lamps: 175 W Pulse Start Metal Halide ED28 Mogul Base with
G3 Globe and Standard Dome Reflector
180.0
2333
2141
2099
2120
1367
546
154
0
0
45°
2850
0° 15° 30°
Plane
0°
90°
180°
0
0
65
53
3
4
5
6
7
8
9
10
58
52
48
44
40
37
35
33
50
44
39
35
31
28
26
24
44
38
32
28
25
22
20
18
40
33
28
24
21
18
16
15
56
51
46
42
39
36
34
32
49
43
38
34
30
28
25
23
44
37
32
28
25
22
20
18
39
33
28
24
21
18
16
15
47
41
36
33
29
27
24
23
42
36
31
27
24
22
19
18
39
32
27
23
20
18
16
14
45
39
35
31
28
26
24
22
41
35
30
27
24
21
19
17
38
32
27
23
20
18
16
14
43
38
34
30
27
25
23
21
40
34
30
26
23
21
19
17
37
31
26
23
20
18
16
14
35
29
25
21
19
16
15
13
REPORT NUMBER: KPB175PG3_AN
Lamps: 175 W Pulse Start Metal Halide ED28 Mogul Base with
G3 Globe and 30° Angle Dome Reflector
Flux CIE Type – Direct
223
692
1170
1512
1427
1533
1349
1140
EFFECTIVE FLOOR CAVITY REFLECTANCE 0.20
RC
80
70
50
30
10
RW 70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10
0 78 78 78 78 76 76 76 76 73 73 73 69 69 69 66 66 66
1 71 67 64 62 69 66 63 61 63 61 59 60 58 57 58 56 55
2 64 58 53 49 62 57 52 48 54 50 47 52 49 46 50 47 45 43
1500
TOTAL LUMINAIRE EFFICIENCY = 58.2%
0.0
2333
2491
2904
3010
3471
2978
3296
3153
3175
90
95
105
115
125
135
145
155
165
175
180
70
78
67
59
53
48
43
40
37
34
32
29
80
50 30
78 78
61 57
51 45
44 37
38 31
33 26
29 23
26 20
24 17
22 16
20 14
COEFFICIENTS OF UTILIZATION - ZONAL CAVITY METHOD
75°
Candela Distribution
0
5
15
25
35
45
55
65
75
RC
RW
0
1
2
3
4
5
6
7
8
9
10
Spacing
Criteria
1.8
1.5
1.1
COEFFICIENTS OF UTILIZATION - ZONAL CAVITY METHOD
EFFECTIVE FLOOR CAVITY REFLECTANCE 0.20
RC
80
70
50
30
RW 70 50 30 10 70 50 30 10 50 30 10 50 30 10 50
0 69 69 69 69 67 67 67 67 63 63 63 60 60 60 57
1 61 57 54 51 59 56 53 50 53 50 48 50 48 46 48
10
0
30 10 0
57 57 56
46 45 43
2 55 49 44 40 53 48 43 40 45 42 38 43 40 37 41 38 36 34
ZONAL LUMEN SUMMARY
ZONE LUMENS %LAMP %FIXT.
0-30 2085
11.9 20.5
0-40 3597
20.6 35.3
0-60 6557
37.5 64.4
0-90 9755
55.7 95.8
90-120
412
2.4
4.1
90-130
415
2.4
4.1
90-150
420
2.4
4.1
90-180
423
2.4
4.2
0-180 10178
58.2 100.0
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
0-deg
90-deg
180-deg
3
4
5
6
7
8
9
10
49
45
41
38
35
33
30
28
42
37
33
30
27
24
22
20
37
32
27
24
21
19
17
16
33
27
23
20
18
16
14
12
48
43
40
37
34
32
29
28
41
36
32
29
26
24
22
20
36
31
27
24
21
19
17
15
32
27
23
20
17
15
14
12
39
34
31
28
25
23
21
19
35
30
26
23
20
18
17
15
31
26
22
19
17
15
14
12
37
33
29
26
24
22
20
19
34
29
25
22
20
18
16
15
31
26
22
19
17
15
13
12
35
31
28
25
23
21
19
18
32
28
24
22
19
17
16
14
30
25
21
19
16
15
13
12
28
24
20
17
15
13
12
11
971
Lighting: Enclosed and Gasketed — Area — HID
966
35
Lighting
25
REPORT NUMBER: KPB175PG3
Lamps: 175 W Pulse Start Metal Halide ED28 Mogul Base with
G3 Globe only
Legend
Degree
0
5
15
For candlepower values of fixtures with other
PSMH lamps, use the following multipliers: for a
100 W (8,500 lumen) PSMH lamp – 0.49; for a 70
W (6,200 lumen) PSMH lamp – 0.36; for a 200 W
(21,000 lumen) PSMH lamp – 1.2. For candlepower
values of fixture with guard, multiply by 0.95.
Mercmaster™ III HID 50-250 Watt Luminaire Photometric Data
100 W HPS
Listed for simultaneous exposure to combustible dusts and flammable gases or vapors.
Degree
0
5
Candela
269
267
Lumens
15
25
35
45
55
65
75
85
90
95
105
115
125
135
145
155
165
175
180
407
571
748
451
848
915
976
1021
1027
1019
953
791
54
13
13
4
0
0
1
117
267
442
380
735
908
1033
1113
Degree
Candela
0
5
1466
1473
15
25
35
45
55
65
75
85
90
95
105
115
125
135
145
155
165
175
180
1607
1675
1757
1316
1502
1377
465
92
16
3
6
40
5
3
3
2
0
1
1
For candlepower values of fixtures with other
HPS lamps, use the following multipliers: for a 70
W (6,400 lumen) HPS lamp – 0.68; for 50 W (4,000
lumen) HPS lamp – 0.43; for candlepower values
of fixture with guard, multiply by 0.95.
REPORT NUMBER: KPB100LG3
Lamps: 100 W High Pressure Sodium C100S54 ED23 - 1/2
Mogul Base with G3 Globe only
TOTAL LUMINAIRE EFFICIENCY = 84.1%
CIE Type – Semi-Direct
Spacing Criteria: 3.1
27
RC
RW
0
1
2
3
4
5
6
7
8
9
10
ZONAL LUMEN SUMMARY
ZONE LUMENS %LAMP %FIXT.
0-30 410
4.3
5.1
0-40
852
9.0
10.7
0-60 1967
20.7
24.6
0-90 5021
52.9
62.9
90-120 2845
29.9
35.6
90-130 2948
31.0
36.9
90-150 2965
31.2
37.1
90-180 2967
31.2
37.1
0-180 7988
84.1 100.0
1109
1002
734
103
9
8
2
0
0
Lumens
142
456
775
1071
1047
1316
1362
589
111
Candela Distribution
Plane
0°
90°
Criteria
1.9
1.7
35
45
55
65
75
180°
1.3
1923
1715
1981
1923
1879
85 1371
90
95
105
115
125
135
145
155
165
175
180
972
680
416
191
40
1
1
0
0
0
2
2
1830 1593 1256 1020 917
1564 1163 599 361 848
1862 1100 287 122 953
1751 869 104
0 869
1272 298
9
0 711
828
140
1
0 424
422
259
93
18
3
2
1
1
1
2
2
89
47
4
51
3
3
2
2
1
2
2
2
4
7
54
3
2
0
1
1
1
2
1
4 144
6 59
92 31
1
2
1
1
0
1
0
1
0
0
0
0
2
0
0
53
32
23
17
13
10
8
7
6
5
5
10
74
60
49
40
33
28
24
21
19
17
15
0
0
72
59
47
38
32
26
23
20
17
15
14
EFFECTIVE FLOOR CAVITY REFLECTANCE 0.20
RC
80
70
50
30
10
RW 70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10
0 77 77 77 77 75 75 75 75 71 71 71 67 67 67 64 64 64
1 68 64 61 57 66 62 59 56 59 56 54 56 54 52 53 51 50
0
0
62
48
70
93
79
69
62
56
51
47
43
40
37
34
70
87
78
70
63
57
52
48
44
41
38
36
COEFFICIENTS OF UTILIZATION - ZONAL CAVITY METHOD
EFFECTIVE FLOOR CAVITY REFLECTANCE 0.20
80
70
50
30
10
50 30 10 70 50 30 10 50 30 10 50 30 10 50 30
87 87 87 85 85 85 85 81 81 81 77 77 77 74 74
74 71 68 76 73 70 67 70 67 65 67 64 62 64 62
64 58 53 68 62 57 53 59 55 51 57 53 50 54 52
55 48 43 61 54 47 43 51 46 42 49 45 41 47 43
48 41 35 55 47 40 35 45 39 34 43 38 34 41 37
42 35 30 51 41 34 29 39 34 29 38 33 29 36 32
37 30 25 46 37 30 25 35 29 25 34 29 25 33 28
34 27 22 43 33 26 22 32 26 22 31 25 21 29 25
30 24 19 40 30 24 19 29 23 19 28 23 19 27 22
23 21 17 37 27 21 17 26 21 17 25 20 17 25 20
25 19 15 35 25 19 15 24 19 15 23 19 15 23 18
REPORT NUMBER: KPB100LG3_AN
Lamps: 100 W High Pressure Sodium C100S54 ED23 - 1/2
Mogul Base with G3 Globe and 30° Angle Reflector
TOTAL LUMINAIRE EFFICIENCY = 65.0%
0.0 45.0 90.0 135.0 180.0 Flux CIE Type – Direct
0 1270 1270 1270 1270 1270
Spacing
5 1317 1302 1271 1227 1211 122
15 1554 1471 1384 1341 1298 398
25 1779 1680 1528 1353 1246 694
10
57
36
26
20
16
13
11
9
8
7
6
RC
RW
0
1
2
3
4
5
6
7
8
9
10
ZONAL LUMEN SUMMARY
ZONE LUMENS %LAMP %FIXT.
0-30 1373
14.5
19.8
0-40 2445
25.7
35.3
0-60 4807
50.6
69.4
0-90 6869
72.3
99.2
90-120
45
0.5
0.6
90-130
53
0.6
0.8
90-150
56
0.6
0.8
90-180
58
0.6
0.8
0-180 6927
72.9 100.0
5
6
33
8
2
1
1
1
0
COEFFICIENTS OF UTILIZATION - ZONAL CAVITY METHOD
EFFECTIVE FLOOR CAVITY REFLECTANCE 0.20
80
70
50
30
10
50 30 10 70 50 30 10 50 30 10 50 30 10 50 30
93 93 93 87 87 87 87 76 76 76 66 66 66 57 57
72 67 62 73 67 62 58 58 54 50 49 46 43 41 39
60 52 46 64 56 49 43 48 42 37 40 36 32 33 30
51 43 36 57 47 40 34 40 34 29 34 29 24 28 24
44 36 29 51 41 33 27 35 28 23 29 24 20 24 19
39 30 24 47 36 28 22 30 24 19 25 20 16 21 17
34 26 20 43 32 24 19 27 21 16 23 17 13 19 14
31 23 17 40 28 21 16 24 18 14 20 15 13 17 13
28 20 15 37 26 19 14 22 16 12 19 14 10 15 11
25 18 13 34 23 17 12 20 14 10 17 12 9 14 10
23 16 11 32 21 15 11 18 13 9 16 11 8 13 9
REPORT NUMBER: KPB100LG3_ST
Lamps: 100 W High Pressure Sodium C100S54 ED23 - 1/2
Mogul Base with G3 Globe and Standard Dome Reflector
TOTAL LUMINAIRE EFFICIENCY = 72.9%
CIE Type – Direct
Spacing Criteria: 1.6
COEFFICIENTS OF UTILIZATION - ZONAL CAVITY METHOD
2 61 55 49 45 59 53 48 44 50 46 43 48 44 41 45 42 40 38
ZONAL LUMEN SUMMARY
ZONE LUMENS %LAMP %FIXT.
0-30 1213
12.8
19.7
0-40 2131
22.4
34.5
0-60 3932
41.4
63.7
0-90 5936
62.5
96.1
90-120
234
2.5
3.8
90-130
236
2.5
3.8
90-150
238
2.5
3.9
90-180
239
2.5
3.9
0-180 6175
65.0 100.0
Legend
Lighting: Enclosed and Gasketed — Area — HID
Lighting
* Photometric data is based on fixtures with a
100-watt clear High Pressure Sodium lamp
(9,400 lumen).
0-deg
90-deg
180-deg
3
4
5
6
7
8
9
10
55
50
46
42
39
36
34
32
47
41
37
33
30
27
25
23
41
35
30
26
23
21
19
17
36
30
25
22
19
17
15
14
53
48
44
41
38
35
33
31
46
40
36
32
29
26
24
22
40
34
30
26
23
21
19
17
36
30
25
22
19
17
15
13
44
38
34
30
28
25
23
21
39
33
29
25
22
20
18
17
35
29
25
21
19
16
15
13
41
36
32
29
26
24
22
20
37
32
28
24
22
20
18
16
34
28
24
21
18
16
14
13
39
35
31
28
25
23
21
20
36
31
27
24
21
19
17
16
33
28
24
20
18
16
14
13
31
26
22
19
17
15
13
12
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
Mercmaster™ III HID 50-250 Watt Luminaire Photometric Data
150 W HPS
Listed for simultaneous exposure to combustible dusts and flammable gases or vapors.
* Photometric data is based on fixtures with a
150-watt clear High Pressure Sodium lamp
(16,000 lumen).
Lumens
15
25
35
45
55
65
75
85
90
95
105
115
125
135
145
155
165
175
180
703
938
1107
892
1420
1542
1629
1675
1665
1643
1515
1072
51
20
19
6
1
0
2
202
442
672
710
1253
1529
1723
1824
Degree
Candela
46
1788
1599
1042
115
16
12
4
0
0
ZONAL LUMEN SUMMARY
ZONE LUMENS %LAMP %FIXT.
0-30
689
4.3
5.3
0-40
1361
8.5
10.5
0-60
3324
20.8
25.6
0-90
8400
52.5
64.7
90-120
4429
27.7
34.1
90-130
4544
28.4
35.0
90-150
4572
28.6
35.2
90-180
4576
28.6
35.3
0-180 12976
81.1 100.0
Lumens
TOTAL LUMINAIRE EFFICIENCY = 69.6%
0
5
2403
2391
15
2624
744
25
2678
1247
REPORT NUMBER: KPB150LG3
Lamps: 150 W High Pressure Sodium C100S54 ED23 - 1/2 Mogul
Base with G3 Globe only
TOTAL LUMINAIRE EFFICIENCY = 81.1%
CIE Type – Semi-Direct
Spacing Criteria: 3.0
RC
RW
0
1
2
3
4
5
6
7
8
9
10
10
30
56
38
29
23
19
16
14
12
11
10
9
10
56
36
26
20
16
13
11
9
8
7
6
0
0
53
32
23
17
13
10
8
7
6
5
4
REPORT NUMBER: KPB150LG3_ST
Lamps: 150 W High Pressure Sodium C100S54 ED23 - 1/2 Mogul
Base with G3 Globe and Standard Dome Reflector
CIE Type – Direct
Spacing Criteria: 1.6
230
70
90
76
67
60
54
49
45
41
38
36
33
COEFFICIENTS OF UTILIZATION - ZONAL CAVITY METHOD
EFFECTIVE FLOOR CAVITY REFLECTANCE 0.20
80
70
50
30
50 30 10 70 50 30 10 50 30 10 50 30 10 50
90 90 90 84 84 84 84 74 74 74 65 65 65 56
70 65 60 71 65 60 56 56 53 49 48 45 42 41
58 51 44 62 54 47 42 46 41 36 39 35 31 33
49 41 34 55 46 38 32 39 33 28 33 28 24 27
43 34 29 50 40 32 26 34 27 22 28 23 19 23
37 29 23 45 35 27 21 30 23 18 25 20 16 21
33 25 19 42 31 23 18 26 20 15 22 17 13 18
30 22 16 38 27 20 15 24 18 13 20 15 11 16
27 19 14 35 25 18 13 21 16 11 18 13 10 15
24 17 12 33 23 16 12 19 14 10 17 12 8 14
22 15 11 31 21 14 10 18 12 9 15 11 7 13
35
2705
1673
COEFFICIENTS OF UTILIZATION - ZONAL CAVITY METHOD
45
55
65
75
85
2250
2444
2246
655
147
1754
2161
2192
851
174
EFFECTIVE FLOOR CAVITY REFLECTANCE 0.20
RC
80
70
50
30
10
0
RW 70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0
0 83 83 83 83 81 81 81 81 77 77 77 74 74 74 70 70 70 69
1 75 71 68 65 73 70 67 64 66 64 62 64 62 60 61 59 58 56
90
26
95
105
115
125
135
145
155
165
175
180
6
11
73
7
6
4
4
2
2
1
ZONAL LUMEN SUMMARY
ZONE LUMENS %LAMP
0-30 2221
13.9
0-40
3895
24.3
0-60
7809
48.8
0-90 11027
68.9
90-120
92
0.6
90-130
104
0.6
90-150
109
0.7
90-180
112
0.7
0-180 11139
69.6
8
13
71
12
3
2
2
1
0
2 67 61 56 51 65 60 55 51 57 53 49 54 51 48 52 49 47 45
%FIXT.
19.9
35.0
70.1
99.0
0.8
0.9
1.0
1.0
100.0
3
4
5
6
7
8
9
10
Candela Distribution
TOTAL LUMINAIRE EFFICIENCY = 61.0%
0.0 45.0 90.0 135.0 180.0 Flux CIE Type – Direct
0 1964 1964 1964 1964 1964
Spacing
25 2755 2587 2288 2095 1853 1081
35
45
55
65
75
85
90
95
105
115
125
135
145
155
165
175
180
2924
2790
3166
3188
3145
2533
2763
2552
2937
2913
2547
927
1490 640
765 449
380 163
114
4
2
5
2
6
0
2
2
4
4
3
0
2
2
2
2415 1885 1276 1416
2015 780 518 1368
1945 410 157 1520
777 77
0 1380
408
1
2 1118
117
0
2 663
14
5
6
6
7
7
6
6
5
3
2
5
8
11
18
8
8
4
6
4
3
2
9
11 239
15 106
63 44
7
5
6
4
2
3
4
2
2
1
2
0
2
Plane
0°
Criteria
2.0
90°
1.7
180°
1.3
ZONAL LUMEN SUMMARY
ZONE LUMENS %LAMP %FIXT.
0-30
1886
11.8
19.3
0-40
3302
20.6
33.8
0-60
6190
38.7
63.5
0-90
9351
58.4
95.9
90-120
389
2.4
4.0
90-130
395
2.5
4.0
90-150
401
2.5
4.1
90-180
404
2.5
4.1
0-180
9754
61.0 100.0
52
46
40
36
32
29
27
24
46
39
33
29
26
23
20
19
41
34
28
24
21
18
16
15
59
53
48
44
41
38
35
33
51
45
39
35
32
29
26
24
46
38
33
29
25
23
20
18
41
34
28
24
21
18
16
15
49
43
38
34
30
28
25
23
44
37
32
28
25
22
20
18
40
33
28
24
21
18
16
14
47
41
36
32
29
27
24
22
43
36
31
27
24
22
20
18
39
33
27
24
20
18
16
14
45
39
35
31
28
26
24
22
41
35
31
27
24
22
19
17
38
32
27
23
20
18
16
14
37
30
25
22
19
16
15
13
REPORT NUMBER: KPB150LG3_AN
Lamps: 150 W High Pressure Sodium C100S54 ED23 - 1/2 Mogul
Base with G3 Globe and 30° Angle Reflector
COEFFICIENTS OF UTILIZATION - ZONAL CAVITY METHOD
Legend
5 2035 2007 1941 1871 1838 187
15 2375 2307 2140 2047 2037 619
61
55
50
46
42
39
36
34
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
0-deg
90-deg
180-deg
RC
RW
0
1
2
3
4
5
6
7
8
9
10
70
72
64
57
80
50 30
72 72
60 57
51 46
EFFECTIVE FLOOR CAVITY REFLECTANCE 0.20
70
50
30
10 70 50 30 10 50 30 10 50 30 10
72 70 70 70 70 66 66 66 63 63 63
54 62 58 55 53 55 53 50 52 50 48
42 55 50 45 41 47 43 40 45 41 39
50
60
50
42
10
30
60
48
40
0
10 0
60 58
47 45
37 36
52
47
43
39
36
34
32
30
44
39
34
31
28
25
23
21
34
28
24
20
18
16
14
13
37
32
29
26
24
22
20
18
33
29
25
22
20
18
16
15
31
26
22
19
17
15
13
12
38
33
28
25
22
20
18
16
50
45
41
38
35
33
30
29
43
38
33
30
27
24
22
21
38
32
28
24
22
19
17
16
33
28
24
20
18
16
14
12
41
36
32
28
26
23
21
20
36
31
27
24
21
19
17
15
33
27
23
20
17
15
14
12
39
34
30
27
25
22
21
19
35
30
26
23
20
18
16
15
32
26
22
19
17
15
13
12
29
24
21
18
15
14
12
11
973
Lighting: Enclosed and Gasketed — Area — HID
Candela
488
459
Lighting
Degree
0
5
For candlepower values of fixtures with other
HPS lamps, use the following multipliers: for a
70 W (6,400 lumen) HPS lamp – 0.40; for a 50 W
(4,000 lumen) HPS lamp – 0.25. For candlepower
values of fixture with guard, multiply by 0.95.
Mercmaster™ III HID 50-250 Watt Luminaire Photometric Data
250 W PSMH
Lighting: Enclosed and Gasketed — Area — HID
Lighting
* Photometric data is based on fixtures with a
250-watt clear Pulse Start Metal Halide lamp
(23,000 lumen).
Zone
0-10
10-20
Lumens
307.05
986.27
20-30
30-40
40-50
50-60
60-70
70-80
80-90
90-100
100-110
110-120
120-130
130-140
140-150
150-160
160-170
170-180
1556.63
2215.28
2539.71
2525.66
2313.2
1992.57
1470.76
689.06
177.72
46
10.39
6.24
5.71
3.95
2.26
.8
Zone
Lumens
0-10 382.83
10-20 1200.76
20-30
30-40
40-50
50-60
60-70
70-80
80-90
90-100
100-110
110-120
120-130
130-140
140-150
150-160
160-170
170-180
1987.77
2662.58
3136.15
3436.26
3412.32
1660.08
278.17
3.43
0
0
0
0
0
0
0
0
Candela Distribution
For candlepower values of fixtures with other
PSMH lamps, (21,000 lumen) PSMH lamp – 0.913.
For candlepower values of fixture with guard,
multiply by 0.95.
TOTAL LUMINAIRE EFFICIENCY = 67.4%
CIE Type – Direct
Spacing Criteria: 2.16
ZONAL LUMEN SUMMARY
ZONE
LUMENS %LAMP %FIXT.
0-30 2849.95 11.4
16.9
0-40 5065.22 20.3
30.1
0-60 10130.59 40.5
60.1
0-90
15907 63.6
94.4
90-120
912.78
3.7
5.4
90-130
923.17
3.7
5.5
90-150
935.11
3.7
5.5
90-180
942.12
3.8
5.6
0-180 16849.24 67.4
100.0
TOTAL LUMINAIRE EFFICIENCY = 72.6%
CIE Type – Direct
Spacing Criteria: 1.58
ZONAL LUMEN SUMMARY
ZONE
LUMENS %LAMP %FIXT.
0-30 3571.36 14.3
19.7
0-40 6233.94 24.9
34.3
0-60 12806.35 51.2
70.5
0-90 18156.91 72.6
100
90-120
3.43
0
0
90-130
3.43
0
0
90-150
3.43
0
0
90-180
3.43
0
0
0-180 18160.34. 72.6
100.0
TOTAL LUMINAIRE EFFICIENCY = 85.5%
RC
RW
0
1
2
3
4
5
6
7
8
9
10
70
79
70
62
56
51
47
43
40
37
34
32
COEFFICIENTS OF UTILIZATION - ZONAL CAVITY METHOD
EFFECTIVE FLOOR CAVITY REFLECTANCE 0.20
80
70
50
30
10
50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10
79 79 79 77 77 77 77 73 73 73 69 69 69 65 65 65
65 62 58 67 63 60 57 60 57 54 56 54 52 53 51 50
55 50 45 60 54 49 44 51 46 43 48 44 41 45 42 39
48 41 36 54 46 40 36 44 39 34 41 37 33 39 35 32
42 35 30 49 41 34 29 38 33 29 36 31 28 34 30 27
37 30 25 45 36 30 25 34 28 24 32 27 23 30 26 23
33 26 21 41 32 26 21 30 25 21 29 24 20 27 23 20
30 23 19 38 29 23 18 27 22 18 26 21 18 25 20 17
27 21 16 35 26 20 16 25 20 16 24 19 16 23 18 15
24 19 15 33 24 18 14 23 18 14 22 17 14 21 17 14
22 17 13 31 22 17 13 21 16 13 20 16 12 19 15 12
0
0
64
48
38
30
25
21
18
16
14
12
11
REPORT NUMBER: KPBG250PST
Lamps: 250 W Metal Halide Pulse Start
Mogul Base
RC
RW
0
1
2
3
4
5
6
7
8
9
10
70
86
78
70
63
57
52
48
44
41
38
35
COEFFICIENTS OF UTILIZATION - ZONAL CAVITY METHOD
EFFECTIVE FLOOR CAVITY REFLECTANCE 0.20
80
70
50
30
10
50 30 10 70 50 30 10 50 30 10 50 30 10 50 30
86 86 86 84 84 84 84 81 81 81 77 77 77 74 74
74 71 68 76 73 70 67 70 67 65 67 65 63 64 62
63 58 53 68 62 57 53 59 55 51 57 53 50 55 52
55 48 43 61 53 47 42 51 46 42 49 45 41 47 43
48 41 35 55 47 40 35 45 39 34 43 38 34 41 37
42 35 30 50 41 34 29 39 34 29 38 33 29 37 32
37 30 25 46 37 30 25 35 29 25 34 29 25 33 28
33 27 22 43 33 26 22 32 26 22 31 25 21 30 25
30 24 19 40 30 23 19 29 23 19 28 23 19 27 22
28 21 17 37 27 21 17 26 21 17 25 20 17 25 20
25 19 15 35 25 19 15 24 19 15 23 18 15 23 18
10
74
61
49
40
33
28
24
21
19
17
15
0
0
73
59
47
38
32
27
23
20
17
15
14
REPORT NUMBER: KPBG250PG
Lamps: 250 W Metal Halide Pulse Start
Mogul Base
Zone
0-10
74.54
10-20
20-30
30-40
304.58
486.47
948.61
40-50
1471.61
EFFECTIVE FLOOR CAVITY REFLECTANCE 0.20
50-60
60-70
70-80
80-90
1887.31
2239.17
2561.7
2747.67
RC
80
70
50
30
10
0
RW 70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0
0 94 94 94 94 87 87 87 87 76 76 76 65 65 65 55 55 55 51
1 80 74 68 63 74 68 63 59 58 54 51 49 46 43 40 38 36 31
90-100
2779.02
100-110
110-120
120-130
130-140
140-150
150-160
160-170
170-180
2564.95
2148.15
1109.49
37.55
3.93
.76
.09
.03
974
CIE Type – General Diffuse
REPORT NUMBER: KPBG250PAN
Lamps: 250 W Metal Halide Pulse Start
Mogul Base
COEFFICIENTS OF UTILIZATION - ZONAL CAVITY METHOD
2 71 61 54 47 65 57 50 44 48 42 38 40 36 32 32 29 26 22
ZONAL LUMEN SUMMARY
ZONE
LUMENS %LAMP %FIXT.
0-30
865.59
3.5
4.1
0-40
1814.2
7.3
8.5
0-60 5173.13 20.7
24.2
0-90 12721.67 50.9
59.5
90-120 7492.124
30
35.1
90-130 8601.61 34.4
40.3
90-150 8643.09 34.6
40.5
90-180 8643.97 34.6
40.5
0-180 21365.63 85.5
100.0
3
4
5
6
7
8
9
10
63
57
52
47
44
40
37
35
52
45
40
35
31
28
25
23
44
36
31
27
23
20
18
16
37
30
25
21
18
15
13
12
58
52
47
43
40
37
34
32
48
42
36
32
29
26
24
22
41
34
29
25
22
19
17
15
34
28
23
19
16
14
12
11
41
35
31
27
24
22
20
18
34
29
24
21
18
16
14
13
29
24
19
16
14
12
10
9
33
29
25
22
20
18
17
15
29
24
20
17
15
13
12
11
25
20
16
13
11
10
9
8
27
23
20
18
16
15
13
12
23
19
16
14
12
11
10
9
20
16
13
11
9
8
7
6
16
13
10
8
7
6
5
4
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
Mercmaster™ III HID 50-250 Watt Luminaire Photometric Data
250 W PSMH
Listed for simultaneous exposure to combustible dusts and flammable gases or vapors.
* Photometric data is based on fixtures with a
250-watt clear Pulse Start Metal Halide lamp
(23,000 lumen).
20-30
30-40
40-50
50-60
60-70
70-80
80-90
90-100
100-110
110-120
120-130
130-140
140-150
150-160
160-170
170-180
438.39
727.7
1709.75
2094.28
4828.69
4189.12
2131.34
748.43
1109.54
701.88
410.51
237.73
123.53
37.79
3.51
.32
Zone
Lumens
0-10
10-20
28.96
214.01
20-30
402.91
TOTAL LUMINAIRE EFFICIENCY = 79%
CIE Type – Semi-Direct
Spacing Criteria: 1.64
ZONAL LUMEN SUMMARY
ZONE LUMENS %LAMP %FIXT.
0-30 689.84
2.8
3.5
0-40 1417.54
5.7
7.2
0-60 5221.56
20.9
26.4
0-90 16370.71
65.5
82.9
90-120 2559.84
10.2
13
90-130 2970.35
11.9
15
90-150 3331.61
13.3
16.9
90-180 3373.23
13.5
17.1
0-180 19743.94
79 100.0
TOTAL LUMINAIRE EFFICIENCY = 84%
CIE Type – Semi-Direct
Spacing Criteria: 1.64
REPORT NUMBER: KPBR250PJ3
Lamps: 250 W Metal Halide Pulse Start
Mogul Base
RC
RW
0
1
2
3
4
5
6
7
8
9
10
70
91
77
66
58
52
47
43
39
36
33
31
COEFFICIENTS OF UTILIZATION - ZONAL CAVITY METHOD
EFFECTIVE FLOOR CAVITY REFLECTANCE 0.20
80
70
50
30
50 30 10 70 50 30 10 50 30 10 50 30 10 50
91 91 91 87 87 87 87 80 80 80 74 74 74 68
70 65 60 73 67 62 57 61 57 53 55 52 49 50
56 48 42 62 54 46 40 48 42 37 43 38 34 39
46 37 30 55 44 36 29 39 32 27 35 29 24 31
39 30 23 49 37 29 22 33 26 20 30 23 18 26
34 25 18 44 32 24 17 29 21 16 25 19 14 22
30 21 15 40 28 20 14 25 18 13 22 16 12 20
26 18 12 37 25 17 12 22 16 11 20 14 9 18
24 16 10 34 22 15 10 20 14 9 18 12 8 16
21 14 9 32 20 13 8 18 12 8 16 11 7 15
19 12 8 29 18 12 7 17 11 7 15 10 6 13
10
30
68
48
35
26
21
17
14
12
11
10
9
10
68
45
31
22
17
13
10
8
7
6
5
0
0
65
42
28
19
14
10
8
6
5
4
4
REPORT NUMBER: KPBR250PJ5
Lamps: 250 W Metal Halide Pulse Start
Mogul Base
30-40
678.83
40-50
1539.03
COEFFICIENTS OF UTILIZATION - ZONAL CAVITY METHOD
50-60
60-70
70-80
80-90
90-100
1537.39
4450.44
5789.28
3160.26
855.15
EFFECTIVE FLOOR CAVITY REFLECTANCE 0.20
RC
80
70
50
30
10
0
RW 70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0
0 97 97 97 97 93 93 93 93 86 86 86 80 80 80 74 74 74 71
1 80 72 66 60 76 69 63 57 63 58 53 57 53 49 52 48 45 42
100-110
1095.13
110-120
120-130
130-140
140-150
150-160
160-170
170-180
596.59
345.11
189.6
82.84
22.91
2.78
.71
ZONAL LUMEN SUMMARY
ZONE LUMENS %LAMP
0-30 645.89
2.6
0-40 1324.72
5.3
0-60 4401.15
17.6
0-90 17801.14
71.2
90-120 2546.87
10.2
90-130 2891.98
11.6
90-150 3164.41
12.7
90-180 3190.80
12.8
0-180 20991.94
84
%FIXT.
3.1
6.3
21
84.8
12.1
13.8
15.1
15.2
100.0
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
2 68 57 48 40 65 54 46 38 49 42 35 44 38 33 39 34 30 27
3
4
5
6
7
8
9
10
60
54
48
44
41
38
35
33
47
40
34
30
27
24
22
20
37
29
24
21
18
16
14
12
29
22
17
14
11
10
8
7
56
50
45
41
38
35
33
31
44
37
32
28
25
23
21
19
35
28
23
20
17
15
13
12
27
21
16
13
11
9
8
7
40
33
29
25
23
21
19
17
32
25
21
18
15
14
12
11
25
19
15
12
10
8
7
6
35
30
26
23
20
18
17
16
29
23
19
16
14
12
11
10
23
17
13
11
9
8
7
6
31
26
23
20
18
16
15
14
26
20
17
14
12
11
10
9
21
15
12
10
8
7
6
5
18
13
9
7
6
5
4
3
975
Lighting: Enclosed and Gasketed — Area — HID
Lumens
28.46
222.99
Lighting
Zone
0-10
10-20
For candlepower values of fixtures with other
PSMH lamps, (21,000 lumen) PSMH lamp – 0.913.
For candlepower values of fixture with guard,
multiply by 0.95.
Mercmaster™ III 400 Luminaire for Hazardous and Wet Locations
High Pressure Sodium and Pulse Start Metal Halide
Listed for simultaneous exposure to combustible dusts and flammable gases or vapors.
Class I, Division 2, Groups A, B, C, D
Class I, Zone 2, AEx nA nR IIC (Z2)
Class I, Zone 2, Ex nR IIC (Z) V
Class I, Zone 2, AEx nR IIC (ZB)
Class II, Division 1 and 2, Groups E, F, G
Class III
Simultaneous Exposure (Class I, Division 2/
Class II, Division 1)
Fixtures Outside Type (Salt Water)
Type 4X
IP66
Lighting: Enclosed and Gasketed — Area — HID
Lighting
Applications
• Enclosed and gasketed fixtures suitable for use in:
— Marine and wet locations
— A wide range of industrial, chemical processing and other areas
where flammable gases and vapors or combustible dusts are
present under conditions defined by the National Electrical
Code as Class I, Division 2; Class II, Division 1 and 2; and
Class III
— In applications involving medium and high mounting heights
— In applications where energy efficient, high lumen output is
required
— The AEx nA nR Mercmaster III fixture is factory sealed and
prevents vapors and gases from entering the globe chamber.
There are no seals or putty required.
— The AEx nR Mercmaster III fixture requires all wiring entries to
be sealed.
— Non-hazardous locations where severe weather conditions,
excessive moisture, dirt, dust, corrosive atmosphere or high
ambient temperatures are encountered
• Typical applications include:
— Pulp and paper mills
— Processing plants
— Chemical plants
— Oil refineries
— Foundries
— Manufacturing plants
— Storage areas
— Waste and sewage treatment
— Other areas where dust, water, dirt and rough usage are a
problem
Features
• Superior corrosion resistance.
• Choice of light sources: high pressure sodium, and pulse start
metal halide.
• Six mounting arrangements to suit any lighting layout: pendant,
ceiling, wall bracket, 25° (angle) stanchion, 90° (straight)
stanchion and cone.
• Hinge has high lip for added safety during installation and
servicing. Hinge and bolt construction assures 360º compression
at all points on ballast housing gasket for positive sealing. Swing
away design of captive bolt and nut simplifies servicing.
• Choice of optical assemblies: prismatic globe; enclosed reflec
tor with sealed lens; or Type V or Type II closed prismatic glass
refractor, with or without guards.
• Wide choice of photometric distributions.
• All fixtures designed to perform in a 104 ºF/40 ºC ambient temper
ature. Selected fixtures are suitable for ambient temperatures up
to 149 ºF/65 ºC.
• Mogul base porcelain lamp holder with nickel-plated contacts
has 392 °F/200 °C rated welded leads, pre-wired to the ballast.
Assures trouble-free operation in installations where high ambient
temperatures are encountered.
• For electrical protection, a ground wire is provided on each
Mercmaster to bond hood and ballast housing.
• Terminal blocks are provided for Zone 2 fixtures to facilitate wiring.
• Standard dome of 30º angle reflectors made of fiberglass rein
forced white polyester. Highly resistant to corrosive atmospheres.
• A wide range of voltages available (120 to 600 Volt) and ballast
types (CWA, CWI and Super CWA).
Enclosed Reflector
Prismatic Glass Globe
12” Glass Refractor
• One-piece ballast housing for each component provides even
heat dissipation for cooler operation and longer ballast life.
• All Mercmaster mounting hoods have provision for easy field in
stallation of fuses in fixtures (see fuse kit listings).
Standard Materials
• Mounting hoods and ballast bodies: cast copperfree (less than
4/10 of 1% copper) aluminum
• Reflectors: Fiberglass reinforced white polyester
• Guards, hardware and catch assemblies: stainless steel
• Globe: heat- and impact-resistant internally fluted glass
• Refractors: prismatic glass
• Enclosed reflector: etched Alzak aluminum with sealed, tempered
heat- and impact-resistant lens
• Body and globe gaskets: high-temperature silicone rubber
Standard Finishes
• Mounting hoods and guards: epoxy powder coat, electrostatically
applied for complete and uniform protection
Options
• AEx nA nR fixtures are available with a Class I, Zone 2 rating. Add
suffix -Z2.
• AEx nR fixtures are available with a Class I, Zone 2 rating. Add
suffix -ZB.
• Ex nR fixtures are available with a Class I, Zone 2 rating. Add
suffix -Z V.
• Quartz Auxiliary comes to full brightness immediately and
remains lit until the HID lamp attains 60-70% of full illumination.
Quartz Auxiliary supplied with relay switch and socket to accept
120V quartz double-contact bayonet base lamp (not included).
(Not suitable for hazardous locations.) Add suffix -E.
• Factory sealed photocontrol available. See PCD2 Series.
• Smart Starter incorporates a 1-1/2-minute timer and performs
as a conventional starter to normally start lamp. Removes
itself from circuit if lamp burns out or is removed from socket.
Eliminates starter failures caused by prolonged operation with
cycling or failing lamps and simplifies finding their location,
reducing maintenance and repair costs. Available for all HPS
and PSMH fixtures. Add suffix -S.
Certifications and Compliances
• UL Standard: UL 1598, UL 1598A, UL 844, UL 60079-0, UL
60079-15
• UL Listed: E10444
V CSA Certification only.
976
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
Mercmaster™ III 400 Luminaires for Hazardous and Wet Locations
High Pressure Sodium and Pulse Start Metal Halide
Listed for simultaneous exposure to combustible dusts and flammable gases or vapors.
Class I, Division 2, Groups A, B, C, D
Class I, Zone 2, AEx nA nR IIC (Z2)
Class I, Zone 2, Ex nR IIC (Z) V
Class I, Zone 2, AEx nR IIC (ZB)
Class II, Division 1 and 2, Groups E, F, G
Class III
Simultaneous Exposure (Class I, Division 2/
Class II, Division 1)
Fixtures Outside Type (Salt Water)
Type 4X
IP66
Illustrated Features
Lighting
High Temperature Sockets
Mogul base high-temperature porcelain
sockets.
Aluminum Inner Reflector
Solid aluminum inner reflector (for
refractor ballast housings only) improves
photometric efficiency.
Globe Chamber
Completely sealed from the ballast
housing and outside vapors/air (nR).
"Safety" High
Hinge
Extra-high hinge
provides additional
protection against
accidental
ballast housing
disengagement
during installation
or maintenance.
Stainless Steel
Latch Assembly
Captive, stainless
steel latch assembly
bolt and nut closes
securely, resists
attack of corrosive
atmospheres.
Swing-away design
simplifies servicing.
Terminal Blocks (Zone 2)
A seven-point terminal block is provided
to facilitate wiring. Terminal block
accommodates wire size ranging from #8
to #24 AWG.
Stainless Steel Inserts
Ballast bodies have stainless steel
threaded inserts to receive stainless steel
screws for reflectors and guard. Prevents
"freezing”, allowing guards and reflectors
to be easily removed and replaced at any
time, without damage to the housing.
Ballast Assembly
Utilizing non-sparking components
avoiding the ignition of gases or vapors
that may be present (nA).
Mounting Hood and Globe Gaskets
Silicone rubber gasket seals out moisture,
dirt and dust. Stays flexible, withstands
high temperatures. Closure design
assures uniform gasket compression.
Electrical Protection
Ground wire provided to bond mounting
hood to ballast housing.
Epoxy Finish
Ballast housing, hoods and guards are
copperfree aluminum with epoxy powder
coat finish.
Photocell
Available for all fixtures except cone and
ceiling mount. Installs through knock-out
in mounting hood. Provides continuous
ON-OFF dusk-to-dawn control.
Prismatic Glass Globes, Refractors
and Enclosed Reflector
Heat-resistant globes, refractors and
enclosed reflector thread into ballast
housing and seal against a high
temperature silicone rubber gasket.
Cooler Operating Cone Hood
Larger sloped surface sheds dusts, dirt
and combustible fibers providing better
heat dissipation.
Fuses
Two screws secure fuse kit to mounting
boss in any Mercmaster mounting hood.
Fuse included.
V CSA Certification only.
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
977
Lighting: Enclosed and Gasketed — Area — HID
Vented Reflectors
Reflectors are thick, tough fiberglass-
reinforced white polyester, vented for
cooler operation. Quickly attach with
furnished stainless steel screws.
Mercmaster™ III 400 Luminaires for Hazerdous and Wet Locations
High Pressure Sodium and Pulse Start Metal Halide
Listed for simultaneous exposure to combustible dusts and flammable gases or vapors.
Class I, Division 2, Groups A, B, C, D
Class I, Zone 2, AEx nA nR IIC (Z2)
Class I, Zone 2, Ex nR IIC (Z) V
Class I, Zone 2, AEx nR IIC (ZB)
Class II, Division 1 and 2, Groups E, F, G
Class III
Simultaneous Exposure (Class I, Division 2/
Class II, Division 1)
Fixtures Outside Type (Salt Water)
Type 4X
IP66
Order using catalog numbering guide below or select catalog number from tables on following pages.
Catalog Numbering Guide
Series:
KP Mercmaster III
400
Lighting: Enclosed and Gasketed — Area — HID
Lighting
KP
A
L
Lamp Type:
L - High Pressure
Sodium
P - Pulse Start
Metal Halide
Mounting:
A - Pendant (rigid
mounting)
C - Ceiling
CH - Pendant Cone Hood
F - Pendant (flexible
mounting)
ST - 90° Stanchion
S - 25° Stanchion
WB - Wall
40
10
Hub Size:
75 - 3/4” NPT
10 - 1” NPT
125 - 1-1/4” NPT
stanchion
150 - 1-1/2” NPT
stanchion
J5
G
MT
Guard Options: ➋
G - Globe Guard
BG - Refractor
Guard
NG - Enclosed
Relfector Guard
Blank - No Guard
Wattage:
Optical Assembly: ➊
25 - 250 W HPS, PSMH ➎ Blank - Glass Globe
32 - 320 W PSMH
J2 - NEMA II Glass
35 - 350 W PSMH
Refractor ➍
40 - 400 W PSMH & HPS J5 - NEMA V Glass
40 - 400 W MH V
Refractor ➍
R - Enclosed Refractor
with Sealed Lens
S
Z2
Options:
E - Emergency Quartz
F - Fuse Kit (Specify
Voltage)
S - Smart Starter
H1 - Photocontrol 120 V
H2 - Photocontrol 208 V
H3 - Photocontrol 240 V
H4 - Photocontrol 277 V
C - Safety Cable
Adapted V
E40 - Export Socket
D - E-40 Export
Socket V
T - Terminal Blocks V
V - Anti-Vibration
Modifications V
X - Appledapter ➏
Mounting Hood
Adapter V
Voltage: ➌
MT - 120/208/240/277,
60Hz
5MT - 120/208/240/
277/480, 60Hz
48 - 480, 60Hz
125 - 120, 50Hz
226 - 220, 60Hz
235 - 230, 50Hz
245 - 240, 50 Hz
C2 - 208, 60 Hz, CWI V
C3 - 240, 60 Hz, CWI V
C6 - 480, 60 Hz, CWI V
C7 - 600, 60 Hz, CWI V
TT - 120/277/347, 60 Hz,
CWA V
Suffix:
Z2 - Zone 2 suffix
(required for
AEx nA nR
rating)
ZB - Zone 2 suffix
(required for
AEx nR rating)
Z - Zone 2 suffix
(required for
Ex nR) V
Refer to “Mounting Hoods and Ballast” page for available Voltage Configuration.
NO DESIGNATION is required for fixtures with standard type globe.
NO DESIGNATION is required for fixtures without guards.
➌ Other voltages available. Contact your local sales representative.
➍ J2 and J5 refractions are not available with Z2 or ZB suffix.
➎ Available for 480 V, 50 Hz and 5MT ballast options. For MT and TT voltage suffix, see Mercmaster III 50-250 Luminaries.
➏ Appledapter is available for use with the pendant, ceiling and angled stanchion mounting only.
V CSA Certification only.
978
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
Mercmaster™ III 400 Luminaire Thermal Performance
Class I, Division 2; Class II, Division 1; Simultaneous Exposure to Hazardous Conditions on Both Classifications
Temperature identification numbers of Mercmaster III – 400 Fixtures.
Class I, Division 2, Groups A, B, C, D
Class I, Zone 2, AEx nA nR IIC (Z2)
Class I, Zone 2, Ex nR IIC (Z) V
Class I, Zone 2, AEx nR IIC (ZB)
Class II, Division 1 and 2, Groups E, F, G
Class III
Simultaneous Exposure (Class I, Division 2/
Class II, Division 1)
Fixtures Outside Type (Salt Water)
Type 4X
IP66
“T” Numbers
Lamp
250
250
HPS
HPS
PSMH
230/110 104/40
T2
T2
T2
T2
T3B
T3B
T4
T4A
325
325
325
325
230/110 131/55
325
325
T2
T2
—
—
T3B
T4A
—
—
T1
325
230/110 149/65
—
—
T2
T2
—
—
T3B
T4
—
—
T1
350
194/90 104/40
350
T3 *
T3 *
T3C
T3C
T1
T1
T1
350
T4
T4A
—
—
—
—
T1
T1
350
194/90 104/40 T2B
T2B
T2B
T2C
194/90 131/55 T2A
T2A
T2B
T2C
—
—
—
—
—
—
—
—
—
—
T2C
—
—
—
—
—
—
—
—
194/90 104/40 T2B
T2B
T2B
T2B
—
—
T3C
T3C
—
—
—
—
194/90 131/55 T2A
T2A
T2A
T2B
—
—
—
—
—
—
—
—
194/90 104/40 T2B
T2B
T2B
T2B
—
—
T3C
T3C
—
—
—
—
194/90 149/65
—
T3 (EF) T3 (EF)
320
PSMH
350
PSMH
194/90 131/55 T2A
T2A
T2A
T2B
—
—
—
—
—
—
—
—
400
PSMH
194/90 104/40 T2A
T2A
T2B
T2B
—
—
T3C
T3C
—
—
—
—
400
MH V
194/90 104/40
T2
T2A
T2A
—
—
T3A
T4
—
—
—
—
T2
“T” Numbers Represent the Maximum Lamp Temperature for Class I, Division 2 Locations and
Maximum Surface Temperature Under Dust Blanket for Class II, Division 1 Locations
“T”
Number
T1
350
325
T2
T2A
T2B
T2C
T2D
T3
T3A
T3B
T3C
T4
T4A
T5
T6
Temp.
Range
(˚ºF)
664842
619662
574617
538572
502536
448500
421446
394419
358392
331356
322329
277320
250275
214248
187212
185
Temp
Range
(ºC)
351450
326350
301325
281300
261280
231260
216230
201215
181200
166180
161165
136160
121135
101120
86100
85
➊ “T” numbers are for Groups E and F only.
V CSA Certification only.
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
979
Lighting: Enclosed and Gasketed — Area — HID
400
Type
Lighting
Watts
Class II, Division 1
Simultaneous Exposure
Supply
Class I, Division 2
Groups E, F and G
Class I, Division 2 / Class II, Division 1
Wire
Ambient
Temp.
Temp.
Globe &
Enclosed
Globe &
Enclosed
Globe &
Enclosed
(°F/°C) ➊ (°F/°C) ➊ Globe Reflector Refractor Reflector Globe Reflector Refractor Reflector Globe Reflector Refractor Reflector
Mercmaster™ III 400 Luminaire Thermal Performance
Class I, Zone 2, AEx nR IIC, AEx nA nR IIC, IP66, NEMA 4X
Temperature identification numbers of Mercmaster III – 400 Fixtures.
Class I, Division 2, Groups A, B, C, D
Class I, Zone 2, AEx nA nR IIC (Z2)
Class I, Zone 2, Ex nR IIC (Z) V
Class I, Zone 2, AEx nR IIC (ZB)
Class II, Division 1 and 2, Groups E, F, G
Class III
Simultaneous Exposure (Class I, Division 2/
Class II, Division 1)
Fixtures Outside Type (Salt Water)
Type 4X
IP66
“T” Numbers
Type
Supply
Wire
Temp.
(°F/°C) ➊
Ambient
Temp.
(°F/°C) ➊
Globe
Globe &
Reflector
Enclosed
Reflector
Globe
Globe &
Reflector
Enclosed
Reflector
HPS
230/110
104/40
T4
T4
T5
T4
T4
T5
HPS
230/110
131/55
T3
T3
T3
T3
T3
T3
HPS
230/110
149/65
—
—
T3
—
—
T3
Lighting
Lamp
Watts
250
Lighting: Enclosed and Gasketed — Area — HID
400
250
320
350
Class 1, Zone 2 AEx nA nR / Ex nR
Class 1, Zone 2 AEx nR
HPS
194/90
104/40
T4
T4
T5
T4
T4
T5
PSMH
194/90
104/40
T3
T3
T3
—
—
—
PSMH
194/90
131/55
T3
T3
T3
—
—
—
PSMH
194/90
104/40
—
—
T3
—
—
—
PSMH
194/90
104/40
T4
T4
T4
T4
T4
T4
PSMH
194/90
131/55
T3
T3
T4
T3
T3
T4
PSMH
194/90
104/40
T4
T4
T4
T4
T4
T4
PSMH
194/90
131/55
T3
T3
T4
T3
T3
T4
400
PSMH
167/75
104/40
T3
T3
T3
T3
T3
T3
400
MH V
167/75
104/40
T3
T3
T3
—
—
—
“T” Numbers represent the maximum surface temperature for luminaries with AEx nA nR and AEx nR rating:
To comply with AEx nR Requirements, all wiring entries must be sealed.
“T”
Number
T1
T2
T3
T4
T5
T6
Temp.
Range (°F)
547-842
394-572
277-392
214-275
187-212
185
Temp.
Range (°C)
301-450
201-300
136-200
101-135
86-100
85
➊ Use 194 °F/90 °C rated supply wire.
V CSA Certification only.
980
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
Mercmaster™ III 400 Luminaires for Hazerdous and Wet Locations
250 W, 400 W HPS
Listed for simultaneous exposure to combustible dusts and flammable gases or vapors.
Class I, Division 2, Groups A, B, C, D
Class I, Zone 2, AEx nA nR IIC (Z2)
Class I, Zone 2, Ex nR IIC (Z) V
Class I, Zone 2, AEx nR IIC (ZB)
Type
Mounting
Class II, Division 1 and 2, Groups E, F, G
Class III
Simultaneous Exposure (Class I, Division 2/
Class II, Division 1)
Lamp
Type
Lamp
Watts
Fixtures Outside Type (Salt Water)
Type 4X
IP66
Hub Size
(Inches)
With Globe
Catalog Numbers ➎
With Type V 12” Refractor
With Enclosed Reflector
3/4
KPAL2575
KPAL2575J5
KPAL2575R
Pendant — One Hub, Rigid Mounting
HPS
250
400
KPAL2510
KPAL2510J5
KPAL2510R
KPAL4075
KPAL4075J5
KPAL4075R
1
KPAL4010
KPAL4010J5
KPAL4010R
3/4
KPCHL2575
KPCHL2575J5
KPCHL2575R
Lighting: Enclosed and Gasketed — Area — HID
1
3/4
Lighting
HPS
Shown with Globe
Pendant Cone — One Hub, Rigid Mounting
HPS
HPS
250
400
1
KPCHL2510
KPCHL2510J5
KPCHL2510R
3/4
KPCHL4075
KPCHL4075J5
KPCHL4075R
1
KPCHL4010
KPCHL4010J5
KPCHL4010R
Shown with 12" Glass Refractor
Ceiling — Five Hubs, Four Close-Up Plugs
HPS
250
HPS
400
3/4
KPCL2575
KPCL2575J5
KPCL2575R
1
KPCL2510
KPCL2510J5
KPCL2510R
3/4
KPCL4075
KPCL4075J5
KPCL4075R
1
KPCL4010
KPCL4010J5
KPCL4010R
Shown with Enclosed Reflector
For Flexible Pendant Mount, change A to F in catalog number.
To order fixture with NEMA Type II refractor, change digits J5 in catalog number to J2. Refractor not available for Z, Z2 or ZB suffix.
For fixtures with guards, add suffix G before adding voltage suffix. BG for refractor. NG for enclosed reflector.
➍ Add the following voltage and frequency designations before Z, Z2 or ZB suffix:
Voltage Suffixes
Lamp Type Lamp Watts
MT
5MT
48
125
225
226
235
245
C2 V
C3 V
C6 V
C7 V
TT V
HPS
250
X
X
X
X
—
X
X
—
—
—
—
—
X
HPS
400
X
X
X
X
—
—
X
—
—
—
—
—
X
PSMH
250
—
X
X
X
—
—
X
—
—
—
—
—
—
PSMH
320
X
X
X
X
—
—
X
—
—
—
—
—
X
PSMH
350
X
X
X
X
—
—
X
—
—
—
—
—
X
PSMH
400
X
X
X
—
—
—
X
—
—
—
—
—
X
400
X
—
—
X
X
—
—
X
X
X
X
X
X
MH V
Voltages:
125 - 120 V 50 Hz
245 - 240 V 50 Hz
MT - 120/208/240/277 V 60 Hz
225 - 225 V 50 Hz
C2 - 208 V 60 Hz, CWI V
5MT - 120/208/240/277/480 V 60 Hz
226 - 220 V 60 Hz
C3 - 240 V 60 Hz, CWI V
C7 - 600 V 60 Hz, CWI V,
48 - 480 V 60 Hz
235 - 230 V 50 Hz
C6 - 480 V 60 Hz, CWI V
TT - 120/277/347 V 60 Hz, CWA V
➎ Add Z2 suffix for factory sealed non-sparking/restricted breathing protection (AEx nA nR). Add ZB suffix for restricted breathing protection (AEx nR).
➏ Add Z for factory sealed restricted breathing protection (Ex nR) V.
V CSA Certification only.
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
981
Mercmaster™ III 400 Luminaires for Hazardous and Wet Locations
250 W, 400 W HPS
Listed for simultaneous exposure to combustible dusts and flammable gases or vapors.
Class I, Division 2, Groups A, B, C, D
Class I, Zone 2, AEx nA nR IIC (Z2)
Class I, Zone 2, Ex nR IIC (Z) V
Class I, Zone 2, AEx nR IIC (ZB)
Type
Mounting
Class II, Division 1 and 2, Groups E, F, G
Class III
Simultaneous Exposure (Class I, Division 2/
Class II, Division 1)
Lamp
Type
Lamp
Watts
Hub Size
(Inches)
Fixtures Outside Type (Salt Water)
Type 4X
IP66
Catalog Numbers ➎
With Type V 12” Refractor
With Globe
With Enclosed Reflector
Lighting: Enclosed and Gasketed — Area — HID
Lighting
Wall Five Hubs, Four Close-Up Plugs
HPS
250
HPS
400
HPS
250
3/4
KPWBL2575
KPWBL2575J5
KPWBL2575R
1
KPWBL2510
KPWBL2510J5
KPWBL2510R
3/4
1
KPWBL4075
KPWBL4075J5
KPWBL4075R
KPWBL4010
KPWBL4010J5
KPWBL4010R
KPSL25125
KPSL25125J5
KPSL25125R
Shown with 12” Glass Refractor
25° Stanchion One Hub
HPS
400
HPS
250
HPS
400
1-1/4
1-1/2
KPSL25150
KPSL25150J5
KPSL25150R
1-1/4
KPSL40125
KPSL40125J5
KPSL40125R
1-1/2
KPSL40150
KPSL40150J5
KPSL40150R
Shown with Prismatic Glass Globe
and Optional Guard
90° Stanchion One Hub
1-1/4
KPSTL25125
KPSTL25125J5
KPSTL25125R
1-1/2
KPSTL25150
KPSTL25150J5
KPSTL25150R
1-1/4
KPSTL40125
KPSTL40125J5
KPSTL40125R
1-1/2
KPSTL40150
KPSTL40150J5
KPSTL40150R
Shown with Prismatic Glass Globe
and Optional Guard
For Flexible Pendant Mount, change A to F in catalog number.
To order fixture with NEMA Type II refractor, change digits J5 in catalog number to J2. Refractor not available for Z, Z2 or ZB suffix.
For fixtures with guards, add suffix G before adding voltage suffix. BG for refractor. NG for enclosed reflector.
➍ Add the following voltage and frequency designations before Z, Z2 or ZB suffix:
Voltage Suffixes
Lamp Type Lamp Watts
MT
5MT
48
125
225
226
235
245
C2 V
C3 V
C6 V
C7 V
TT V
HPS
250
X
X
X
X
—
X
X
—
—
—
—
—
X
HPS
400
X
X
X
X
—
—
X
—
—
—
—
—
X
PSMH
250
—
X
X
X
—
—
X
—
—
—
—
—
—
PSMH
320
X
X
X
X
—
—
X
—
—
—
—
—
X
PSMH
350
X
X
X
X
—
—
X
—
—
—
—
—
X
PSMH
400
X
X
X
—
—
—
X
—
—
—
—
—
X
400
X
—
—
X
X
—
—
X
X
X
X
X
X
MH V
Voltages:
125 - 120 V 50 Hz
245 - 240 V 50 Hz
MT - 120/208/240/277 V 60 Hz
225 - 225 V 50 Hz
C2 - 208 V 60 Hz, CWI V
5MT - 120/208/240/277/480 V 60 Hz
226 - 220 V 60 Hz
C3 - 240 V 60 Hz, CWI V
C7 - 600 V 60 Hz, CWI V,
48 - 480 V 60 Hz
235 - 230 V 50 Hz
C6 - 480 V 60 Hz, CWI V
TT - 120/277/347 V 60 Hz, CWA V
➎ Add Z2 suffix for factory sealed non-sparking/restricted breathing protection (AEx nA nR). Add ZB suffix for restricted breathing protection (AEx nR).
➏ Add Z for factory sealed restricted breathing protection (Ex nR) V.
V CSA Certification only.
982
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
Mercmaster™ III 400 Luminaires for Hazardous and Wet Locations
250 W, 320 W, 350 W, 400 W PSMH
Listed for simultaneous exposure to combustible dusts and flammable gases or vapors.
Class I, Division 2, Groups A, B, C, D
Class I, Zone 2, AEx nA nR IIC (Z2)
Class I, Zone 2, Ex nR IIC (Z) V
Class I, Zone 2, AEx nR IIC (ZB)
Type
Mounting
Class II, Division 1 and 2, Groups E, F, G
Class III
Simultaneous Exposure (Class I, Division 2/
Class II, Division 1)
Lamp
Type
Lamp
Watts
Hub Size
(Inches)
With Globe
Fixtures Outside Type (Salt Water)
Type 4X
IP66
Catalog Numbers ➎
With Type V 12” Refractor
With Enclosed Reflector
Pendant One Hub, Rigid Mounting
PSMH
320
PSMH
350
PSMH
400
3/4
KPAP2575
KPAP2575J5
KPAP2575R
1
KPAP2510
KPAP2510J5
KPAP2510R
3/4
KPAP3275
KPAP3275J5
KPAP3275R
1
KPAP3210
KPAP3210J5
KPAP3210R
3/4
KPAP3575
KPAP3575J5
KPAP3575R
1
KPAP3510
KPAP3510J5
KPAP3510R
3/4
KPAP4075
KPAP4075J5
KPAP4075R
1
KPAP4010
KPAP4010J5
KPAP4010R
3/4
KPCHP2575
KPCHP2575J5
KPCHP2575R
1
KPCHP2510
KPCHP2510J5
KPCHP2510R
3/4
KPCHP3275
KPCHP3275J5
KPCHP3275R
1
KPCHP3210
KPCHP3210J5
KPCHP3210R
3/4
KPCHP3575
KPCHP3575J5
KPCHP3575R
1
KPCHP3510
KPCHP3510J5
KPCHP3510R
3/4
KPCHP4075
KPCHP4075J5
KPCHP4075R
1
KPCHP4010
KPCHP4010J5
KPCHP4010R
3/4
KPCP2575
KPCP2575J5
KPCP2575R
1
KPCP2510
KPCP2510J5
KPCP2510R
3/4
KPCP3275
KPCP3275J5
KPCP3275R
1
KPCP3210
KPCP3210J5
KPCP3210R
3/4
KPCP3575
KPCP3575J5
KPCP3575R
1
KPCP3510
KPCP3510J5
KPCP3510R
3/4
KPCP4075
KPCP4075J5
KPCP4075R
1
KPCP4010
KPCP4010J5
KPCP4010R
Lighting: Enclosed and Gasketed — Area — HID
Shown with Globe
250 ➐
Lighting
PSMH
Pendant Cone One Hub, Rigid Mounting
PSMH
PSMH
PSMH
Shown with 12" Glass Refractor
PSMH
250 ➐
320
350
400
Ceiling Five Hubs, Four Close-Up Plugs
PSMH
PSMH
PSMH
Shown with Enclosed Refractor
PSMH
250 ➐
320
350
400
For Flexible Pendant Mount, change A to F in catalog number.
To order fixture with NEMA Type II refractor, change digits J5 in catalog number to J2. Refractor not available for Z, Z2 or ZB suffix.
For fixtures with guards, add suffix G before adding voltage suffix. BG for refractor. NG for enclosed reflector.
➍ Add the following voltage and frequency designations before Z, Z2 or ZB suffix:
Voltage Suffixes
Lamp Type Lamp Watts
MT
5MT
48
125
225
226
235
245
C2 V
C3 V
C6 V
C7 V
TT V
HPS
250
X
X
X
X
—
X
X
—
—
—
—
—
X
HPS
400
X
X
X
X
—
—
X
—
—
—
—
—
X
PSMH
250
—
X
X
X
—
—
X
—
—
—
—
—
—
PSMH
320
X
X
X
X
—
—
X
—
—
—
—
—
X
PSMH
350
X
X
X
X
—
—
X
—
—
—
—
—
X
PSMH
400
X
X
X
—
—
—
X
—
—
—
—
—
X
400
X
—
—
X
X
—
—
X
X
X
X
X
X
MH V
Voltages:
125 - 120 V 50 Hz
245 - 240 V 50 Hz
MT - 120/208/240/277 V 60 Hz
225 - 225 V 50 Hz
C2 - 208 V 60 Hz, CWI V
5MT - 120/208/240/277/480 V 60 Hz
226 - 220 V 60 Hz
C3 - 240 V 60 Hz, CWI V
C7 - 600 V 60 Hz, CWI V,
48 - 480 V 60 Hz
235 - 230 V 50 Hz
C6 - 480 V 60 Hz, CWI V
TT - 120/277/347 V 60 Hz, CWA V
➎ Add Z2 suffix for factory sealed non-sparking/restricted breathing protection (AEx nA nR). Add ZB suffix for restricted breathing protection (AEx nR).
➏ Add Z for factory sealed restricted breathing protection (Ex nR) V.
V CSA Certification only.
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
983
Mercmaster™ III 400 Luminaires for Hazardous and Wet Locations
250 W, 320 W, 350 W, 400 W PSMH
Listed for simultaneous exposure to combustible dusts and flammable gases or vapors.
Class I, Division 2, Groups A, B, C, D
Class I, Zone 2, AEx nA nR IIC (Z2)
Class I, Zone 2, Ex nR IIC (Z) V
Class I, Zone 2, AEx nR IIC (ZB)
Type
Mounting
Class II, Division 1 and 2, Groups E, F, G
Class III
Simultaneous Exposure (Class I, Division 2/
Class II, Division 1)
Lamp
Type
Lamp
Watts
Fixtures Outside Type (Salt Water)
Type 4X
IP66
Hub Size
(Inches)
With Globe
Catalog Numbers ➎
With Type V 12” Refractor
With Enclosed Reflector
3/4
KPWBP2575
KPWBP2575J5
KPWBP2575R
1
KPWBP2510
KPWBP2510J5
KPWBP2510R
3/4
KPWBP3275
KPWBP3275J5
KPWBP3275R
KPWBP3210
KPWBP3210J5
KPWBP3210R
KPWBP3575
KPWBP3575J5
KPWBP3575R
KPWBP3510
KPWBP3510J5
KPWBP3510R
KPWBP4075
KPWBP4075J5
KPWBP4075R
KPWBP4010
KPWBP4010J5
KPWBP4010R
1-1/4
KPSP25125
KPSP25125J5
KPSP25125R
1-1/2
KPSP25150
KPSP25150J5
KPSP25150R
1-1/4
KPSP32125
KPSP32125J5
KPSP32125R
1-1/2
KPSP32150
KPSP32150J5
KPSP32150R
1-1/4
KPSP35125
KPSP35125J5
KPSP35125R
1-1/2
KPSP35150
KPSP35150J5
KPSP35150R
1-1/4
KPSP40125
KPSP40125J5
KPSP40125R
1-1/2
KPSP40150
KPSP40150J5
KPSP40150R
1-1/4
KPSTP25125
KPSTP25125J5
KPSTP25125R
1-1/2
KPSTP25150
KPSTP25150J5
KPSTP25150R
1-1/4
KPSTP32125
KPSTP32125J5
KPSTP32125R
1-1/2
KPSTP32150
KPSTP32150J5
KPSTP32150R
1-1/4
KPSTP35125
KPSTP35125J5
KPSTP35125R
1-1/2
KPSTP35150
KPSTP35150J5
KPSTP35150R
1-1/4
KPSTP40125
KPSTP40125J5
KPSTP40125R
1-1/2
KPSTP40150
KPSTP40150J5
KPSTP40150R
Lighting
Wall Five Hubs, Four Close-Up Plugs
PSMH
PSMH
Lighting: Enclosed and Gasketed — Area — HID
PSMH
Shown with 12” Glass Refractor
250 ➐
320
350
PSMH
400
PSMH
250 ➐
PSMH
320
1
3/4
1
3/4
1
25° Stanchion One Hub
PSMH
Shown with Prismatic Glass Globe
and Optional Guard
350
PSMH
400
PSMH
250 ➐
90° Stanchion One Hub
PSMH
Shown with Prismatic Glass Globe
and Optional Guard
320
PSMH
350
PSMH
400
For Flexible Pendant Mount, change A to F in catalog number.
To order fixture with NEMA Type II refractor, change digits J5 in catalog number to J2. Refractor not available for Z, Z2 or ZB suffix.
For fixtures with guards, add suffix G before adding voltage suffix. BG for refractor. NG for enclosed reflector.
➍ Add the following voltage and frequency designations before Z, Z2 or ZB suffix:
Voltage Suffixes
Lamp Type Lamp Watts
MT
5MT
48
125
225
226
235
245
C2 V
C3 V
C6 V
C7 V
TT V
HPS
250
X
X
X
X
—
X
X
—
—
—
—
—
X
HPS
400
X
X
X
X
—
—
X
—
—
—
—
—
X
PSMH
250
—
X
X
X
—
—
X
—
—
—
—
—
—
PSMH
320
X
X
X
X
—
—
X
—
—
—
—
—
X
PSMH
350
X
X
X
X
—
—
X
—
—
—
—
—
X
PSMH
400
X
X
X
—
—
—
X
—
—
—
—
—
X
400
X
—
—
X
X
—
—
X
X
X
X
X
X
MH V
Voltages:
125 - 120 V 50 Hz
245 - 240 V 50 Hz
MT - 120/208/240/277 V 60 Hz
225 - 225 V 50 Hz
C2 - 208 V 60 Hz, CWI V
5MT - 120/208/240/277/480 V 60 Hz
226 - 220 V 60 Hz
C3 - 240 V 60 Hz, CWI V
C7 - 600 V 60 Hz, CWI V,
48 - 480 V 60 Hz
235 - 230 V 50 Hz
C6 - 480 V 60 Hz, CWI V
TT - 120/277/347 V 60 Hz, CWA V
➎ Add Z2 suffix for factory sealed non-sparking/restricted breathing protection (AEx nA nR). Add ZB suffix for restricted breathing protection (AEx nR).
➏ Add Z for factory sealed restricted breathing protection (Ex nR) V.
V CSA Certification only.
984
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
Mercmaster™ III 400 Luminaires for Hazardous and Wet Locations
400 W MH V
Listed for simultaneous exposure to combustible dusts and flammable gases or vapors.
Class I, Division 2, Groups A, B, C, D
Class I, Zone 2, AEx nA nR IIC (Z2)
Class I, Zone 2, Ex nR IIC (Z) V
Class I, Zone 2, AEx nR IIC (ZB)
Type
Mounting
Class II, Division 1 and 2, Groups E, F, G
Class III
Simultaneous Exposure (Class I, Division 2/
Class II, Division 1)
Lamp
Type
Lamp
Watts
Hub Size
(Inches)
With Globe
Fixtures Outside Type (Salt Water)
Type 4X
IP66
Catalog Numbers ➎
With Type V 12” Refractor
With Enclosed Reflector
Pendant One Hub, Rigid Mounting
400
KPAH4075
KPAH4075J5
KPAH4075R
1
KPAH4010
KPAH4010J5
KPAH4010R
3/4
KPCHH4075
KPCHH4075J5
KPCHH4075R
1
KPCHH4010
KPCHH4010J5
KPCHH4010R
3/4
KPCH4075
KPCH4075J5
KPCH4075R
1
KPCH4010
KPCH4010J5
KPCH4010R
Lighting: Enclosed and Gasketed — Area — HID
3/4
Lighting
MH V
Shown with Globe
Pendant Cone One Hub, Rigid Mounting
MH V
400
Shown with 12" Glass Refractor
Ceiling Five Hubs, Four Close-Up Plugs
MH V
400
Shown with Enclosed Refractor
For Flexible Pendant Mount, change A to F in catalog number.
To order fixture with NEMA Type II refractor, change digits J5 in catalog number to J2. Refractor not available for Z, Z2 or ZB suffix.
For fixtures with guards, add suffix G before adding voltage suffix. BG for refractor. NG for enclosed reflector.
➍ Add the following voltage and frequency designations before Z, Z2 or ZB suffix:
Voltage Suffixes
Lamp Type Lamp Watts
MT
5MT
48
125
225
226
235
245
C2 V
C3 V
C6 V
C7 V
TT V
HPS
250
X
X
X
X
—
X
X
—
—
—
—
—
X
HPS
400
X
X
X
X
—
—
X
—
—
—
—
—
X
PSMH
250
—
X
X
X
—
—
X
—
—
—
—
—
—
PSMH
320
X
X
X
X
—
—
X
—
—
—
—
—
X
PSMH
350
X
X
X
X
—
—
X
—
—
—
—
—
X
PSMH
400
X
X
X
—
—
—
X
—
—
—
—
—
X
400
X
—
—
X
X
—
—
X
X
X
X
X
X
MH V
Voltages:
125 - 120 V 50 Hz
245 - 240 V 50 Hz
MT - 120/208/240/277 V 60 Hz
225 - 225 V 50 Hz
C2 - 208 V 60 Hz, CWI V
5MT - 120/208/240/277/480 V 60 Hz
226 - 220 V 60 Hz
C3 - 240 V 60 Hz, CWI V
C7 - 600 V 60 Hz, CWI V,
48 - 480 V 60 Hz
235 - 230 V 50 Hz
C6 - 480 V 60 Hz, CWI V
TT - 120/277/347 V 60 Hz, CWA V
➎ Add Z2 suffix for factory sealed non-sparking/restricted breathing protection (AEx nA nR). Add ZB suffix for restricted breathing protection (AEx nR).
➏ Add Z for factory sealed restricted breathing protection (Ex nR) V.
➐ Available for 480 V, 50 Hz and 5MT ballast options. For MT and TT voltage suffix, see Mercmaster III 50-250 Luminaries.
V CSA Certification only.
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
985
Mercmaster™ III 400 Luminaires for Hazardous and Wet Locations
400 W MH V
Listed for simultaneous exposure to combustible dusts and flammable gases or vapors.
Class I, Division 2, Groups A, B, C, D
Class I, Zone 2, AEx nA nR IIC (Z2)
Class I, Zone 2, Ex nR IIC (Z) V
Class I, Zone 2, AEx nR IIC (ZB)
Type
Mounting
Class II, Division 1 and 2, Groups E, F, G
Class III
Simultaneous Exposure (Class I, Division 2/
Class II, Division 1)
Lamp
Type
Lamp
Watts
Fixtures Outside Type (Salt Water)
Type 4X
IP66
Hub Size
(Inches)
With Globe
Catalog Numbers ➎
With Type V 12” Refractor
With Enclosed Reflector
3/4
KPWBH4075
KPWBH4075J5
KPWBH4075R
KPWBH4010
KPWBH4010J5
KPWBH4010R
1-1/4
KPSH40125
KPSH40125J5
KPSH40125R
1-1/2
KPSH40150
KPSH40150J5
KPSH40150R
1-1/4
KPSTH40125
KPSTH40125J5
KPSTH40125R
1-1/2
KPSTH40150
KPSTH40150J5
KPSTH40150R
Lighting: Enclosed and Gasketed — Area — HID
Lighting
Wall Five Hubs, Four Close-Up Plugs
MH V
400
MH V
400
MH V
400
1
Shown with 12” Glass Refractor
25° Stanchion One Hub
Shown with Prismatic Glass Globe
and Optional Guard
90° Stanchion One Hub
Shown with Prismatic Glass Globe
and Optional Guard
For Flexible Pendant Mount, change A to F in catalog number.
To order fixture with NEMA Type II refractor, change digits J5 in catalog number to J2. Refractor not available for Z, Z2 or ZB suffix.
For fixtures with guards, add suffix G before adding voltage suffix. BG for refractor. NG for enclosed reflector.
➍ Add the following voltage and frequency designations before Z, Z2 or ZB suffix:
Voltage Suffixes
Lamp Type Lamp Watts
MT
5MT
48
125
225
226
235
245
C2 V
C3 V
C6 V
C7 V
TT V
HPS
250
X
X
X
X
—
X
X
—
—
—
—
—
X
HPS
400
X
X
X
X
—
—
X
—
—
—
—
—
X
PSMH
250
—
X
X
X
—
—
X
—
—
—
—
—
—
PSMH
320
X
X
X
X
—
—
X
—
—
—
—
—
X
PSMH
350
X
X
X
X
—
—
X
—
—
—
—
—
X
PSMH
400
X
X
X
—
—
—
X
—
—
—
—
—
X
400
X
—
—
X
X
—
—
X
X
X
X
X
X
MH V
Voltages:
125 - 120 V 50 Hz
245 - 240 V 50 Hz
MT - 120/208/240/277 V 60 Hz
225 - 225 V 50 Hz
C2 - 208 V 60 Hz, CWI V
5MT - 120/208/240/277/480 V 60 Hz
226 - 220 V 60 Hz
C3 - 240 V 60 Hz, CWI V
C7 - 600 V 60 Hz, CWI V,
48 - 480 V 60 Hz
235 - 230 V 50 Hz
C6 - 480 V 60 Hz, CWI V
TT - 120/277/347 V 60 Hz, CWA V
➎ Add Z2 suffix for factory sealed non-sparking/restricted breathing protection (AEx nA nR). Add ZB suffix for restricted breathing protection (AEx nR).
➏ Add Z for factory sealed restricted breathing protection (Ex nR) V.
V CSA Certification only.
986
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
Mercmaster™ III 400 Luminaire Mounting Hood and Ballast Bodies
High Pressure Sodium and Pulse Start Metal Halide - Hazardous and Wet Locations
Listed for simultaneous exposure to combustible dusts and flammable gases or vapors.
Class I, Division 2, Groups A, B, C, D
Class I, Zone 2, AEx nA nR IIC (Z2)
Class I, Zone 2, Ex nR IIC (Z) V
Class I, Zone 2, AEx nR IIC (ZB)
Class II, Division 1 and 2, Groups E, F, G
Class III
Simultaneous Exposure (Class I, Division 2/
Class II, Division 1)
Fixtures Outside Type (Salt Water)
Type 4X
IP66
Mounting Hoods
Description
Hub Size (Inches)
Catalog Number
Pendant
3/4
KPA-75
1
KPA-100
3/4
KPAF-75
1
KPAF-100
3/4
KPCH-75
1
KPCH-100
Lighting
One Hub, Rigid Mounting
Pendant — Flexible
One Hub, Flexible Mounting
Pendant Cone
Ceiling
Five Hubs, Four Close-Up Plugs
3/4
KPC-75
1
KPC-100
3/4
KPWB-75
1
KPWB-100
Wall
Five Hubs, Four Close-Up Plugs
25° Stanchion
One Hub
1-1/4
KPS-125
1-1/2
KPS-150
1-1/4
KPST-125
1-1/2
KPST-150
90° Stanchion
One Hub
Ballast Bodies
High Pressure Sodium — Constant Wattage (Min. P.F. 90%)
Pulse Start Metal Halide — Super Constant Wattage (Min. P.F. 90%)
Lamp
Type
HPS
HPS
PSMH
PSMH
PSMH
PSMH
MH V
Lamp
Watts
250
400
250
320
350
400
400
Catalog
Numbers ➋➍
KPB250L ➊➌
KPB400L ➊➌
KPB250P ➊➌
KPB320P ➊➌
KPB350P ➊➌
KPB400P ➊➌
KPB400H
Voltages:
MT - 120/208/240/277 V 60 Hz
5MT - 120/208/240/277/480 V 60 Hz
48 - 480 V 60 Hz
MT
X
X
—
X
X
X
X
5MT
X
X
X
X
X
X
—
48
X
X
X
X
X
X
—
125 - 120 V 50 Hz
225 - 225 V 50 Hz
226 - 220 V 60 Hz
235 - 230 V 50 Hz
125
X
X
X
X
X
—
X
225
—
—
—
—
—
—
X
Voltage Suffixes
226
235
245
X
X
—
—
X
—
—
X
—
—
X
—
—
X
—
—
X
—
—
—
X
245 - 240 V 50 Hz
C2 - 208 V 60 Hz, CWI V
C3 - 240 V 60 Hz, CWI V
C6 - 480 V 60 Hz, CWI V
C2 V
—
—
—
—
—
—
X
C3 V
—
—
—
—
—
—
X
C6 V
—
—
—
—
—
—
X
C7 V
—
—
—
—
—
—
X
TT V
X
X
X
X
X
X
X
C7 - 600 V 60 Hz, CWI V,
TT - 120/277/347 V 60 Hz, CWA V
➊ Add -S after voltage designation for ballast body with Smart Starter (HPS and PSMH only).
➋ Add -E after voltage designation for ballast body with provision for Quartz Emergency Light (not suitable for hazardous location).
➌ Add Z2 suffix for factory sealed non-sparking/restricted breathing protection (AEx nA nR). Add ZB suffix for restricted breathing protection (AEx nR).
➍ Add Z for factory sealed restricted breathing protection (Ex nR) V.
V CSA Certification only.
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
987
Lighting: Enclosed and Gasketed — Area — HID
One Hub, Rigid
Mercmaster™ III 400 Luminaire Optics and Accessories
High Pressure Sodium and Pulse Start Metal Halide - Hazardous and Wet Locations
Listed for simultaneous exposure to combustible dusts and flammable gases or vapors.
Description
Catalog Number
Lighting
Prismatic Glass Globes — Heat-Resistant
Clear
VPGL-4HR
Heat- and impact-resistant glass lens
KPR-4HB
Glass Globe
Lighting: Enclosed and Gasketed — Area — HID
Enclosed Reflector Assembly
Enclosed Reflector
Light Distribution
IES/NEMA Distribution Curves
Catalog Number
Closed Prismatic Glass Refractors ➌ — All Heat-Resistant
NEMA Type II
KPRF400-2
NEMA Type V
KPRF400-5
Glass Refractor
Item
Description
Catalog Number
White Polyester Reflectors Furnished with stainless steel screws
For use with globe fixtures
Standard and Deep Dome
Standard Dome
CMR4-ST ➊
30° Angle
CMR4-AN
Deep Dome
CMR4-DD ➊➋
Globe Guard
KPGU400
Refractor Guard
KPBG12
Enclosed Reflector Guard
GHB7000-NG
30° Angle
Guards
Globe Guard
Refractor Guard
Enclosed Reflector Guard
➊ Contact your local sales representative if used with KPWB or KPST mounting hoods.
➋ Complies Dark Skies.
➌ Not suitable for use with Z, Z2 or ZB suffixes (Zone 2).
988
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
Mercmaster™ III 400 Luminaire Electrical Specifications and Fuse Kits
High Pressure Sodium and Pulse Start Metal Halide - Hazardous and Wet Locations
Listed for simultaneous exposure to combustible dusts and flammable gases or vapors.
Class I, Division 2, Groups A, B, C, D
Class I, Zone 2, AEx nA nR IIC (Z2)
Class I, Zone 2, Ex nR IIC (Z) V
Class I, Zone 2, AEx nR IIC (ZB)
Class II, Division 1 and 2, Groups E, F, G
Class III
Simultaneous Exposure (Class I, Division 2/
Class II, Division 1)
Electrical Specifications
Electrical Specifications
Operating
Amps
Total
Watts
2.00
1.20
1.00
0.85
0.60
0.40
1.85
0.95
2.50
1.50
1.30
1.10
0.93
0.65
2.75
1.44
295
295
295
295
295
295
300
300
3.30
1.80
1.60
1.40
1.00
0.80
3.70
1.85
3.80
2.20
1.90
1.70
1.32
1.00
4.00
2.00
465
465
465
465
464
465
465
465
1.96
1.13
0.98
0.85
0.62
0.32
0.45
1.90
1.00
2.50
1.45
1.25
1.10
0.90
0.69
0.60
2.60
1.35
291
291
291
291
291
298
285
288
288
2.60
1.50
1.30
1.15
0.70
0.60
2.28
1.14
3.25
1.90
1.65
1.40
1.10
0.80
3.05
1.60
368
368
368
368
368
368
365
365
3.30
1.90
1.65
1.40
0.85
0.75
2.45
1.26
3.60
2.10
1.80
1.55
1.20
0.90
3.34
1.74
400
400
400
400
400
400
394
394
3.50
2.00
1.75
1.50
1.10
0.90
3.17
1.65
4.00
2.30
2.00
1.25
1.35
1.00
3.90
2.00
454
454
454
454
452
454
454
454
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
Line
Type of
Voltage
Ballast ➊
Frequency
400 Watt Metal Halide V
120
C.W.A.
60
208
C.W.A.
60
240
C.W.A.
60
277
C.W.A.
60
347
C.W.A.
60
480
C.W.I.
60
600
C.W.I.
60
120
C.W.A.
50
220
C.W.A.
50
240
C.W.A.
50
Starting
Amps
Operating
Amps
Total
Watts
3.25
1.90
1.80
1.70
1.40
0.85
0.30
2.70
1.50
1.50
4.00
2.30
2.00
1.75
1.75
1.00
0.70
4.10
2.10
2.10
458
458
458
458
458
462
475
462
462
462
Fuse Kit
Order fuses as a separate item by catalog number from right columns.
Lamp
Watts
250
250
320
350
400
Volts
120
208
240
277
347V
480
120
230
480
230
120
208
240
277
347V
480
120
230
120
208
240
277
347V
480
120
230
120
208
240
277
347V
480
120
230
Fuse
Quantity
Required
1
2
2
1
1
2
1
2
2
1
1
2
2
1
1
2
1
2
1
2
2
1
1
2
1
2
1
2
2
1
1
2
1
2
Fuse Catalog Number
HPS
F7
F4
F4
F3
F3
F2
F7
F4
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
F15
F8
F8
F5
F5
F5
F10
F6
PSMH
—
—
—
—
F3
—
—
—
F2
F3
F9
F6
F5
F4
F3
F3
F10
F5
F10
F7
F5
F5
F3
F3
F10
F5
F10
F7
F5
F5
F5
F3
F10
F5
MH V
—
—
—
—
F3
—
—
—
—
—
—
—
—
—
F3
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
F5
—
—
—
➊ C.W.A. – Constant Wattage Autotransformer. HX-HPF – High Reactance
High Power Factor Autotransformer.
Super C.W.A. – Super Constant Wattage Autotransformer.
V CSA Certification only.
989
Lighting: Enclosed and Gasketed — Area — HID
Starting
Amps
Lighting
Line
Type of
Voltage
Ballast ➊
Frequency
250 Watt High Pressure Sodium
120
C.W.A.
60
208
C.W.A.
60
240
C.W.A.
60
277
C.W.A.
60
C.W.A.
60
347V
480
C.W.A.
60
120
C.W.A.
50
230
C.W.A.
50
400 Watt High Pressure Sodium
120
C.W.A.
60
208
C.W.A.
60
240
C.W.A.
60
277
C.W.A.
60
C.W.A.
60
347V
480
C.W.A.
60
120
C.W.A.
50
230
C.W.A.
50
250 Watt Pulse Start Metal Halide
120
C.W.A.
60
208
C.W.A.
60
240
C.W.A.
60
277
C.W.A.
60
C.W.A.
60
347V
480
C.W.A.
60
480
Super C.W.A.
60
120
Super C.W.A.
50
230
Super C.W.A.
50
320 Watt Pulse Start Metal Halide
120
Super C.W.A.
60
208
Super C.W.A.
60
240
Super C.W.A.
60
277
Super C.W.A.
60
Super C.W.A.
60
347V
480
Super C.W.A.
60
120
Super C.W.A.
50
230
Super C.W.A.
50
350 Watt Pulse Start Metal Halide
120
Super C.W.A.
60
208
Super C.W.A.
60
240
Super C.W.A.
60
277
Super C.W.A.
60
Super C.W.A.
60
347V
480
Super C.W.A.
60
120
Super C.W.A.
50
230
Super C.W.A.
50
400 Watt Pulse Start Metal Halide
120
Super C.W.A.
60
208
Super C.W.A.
60
240
Super C.W.A.
60
277
Super C.W.A.
60
Super C.W.A.
60
347V
480
Super C.W.A.
60
120
Super C.W.A.
50
230
Super C.W.A.
50
Fixtures Outside Type (Salt Water)
Type 4X
IP66
Mercmaster™ III 400 Luminaire Dimensions and Weights
High Pressure Sodium and Pulse Start Metal Halide - Hazardous and Wet Locations
Listed for simultaneous exposure to combustible dusts and flammable gases or vapors.
Wall
Lighting: Enclosed and Gasketed — Area — HID
Lighting
Pendant with Globe,
Guard and Reflectors
25° Stanchion
Cone
Ceiling with Refractor
Enclosed Reflector and Guards
90° Stanchion
Deep Dome
Mercmaster III – 400 Ballast and Accessory Weights
Lamp Watts
Ballast Housing (Wt. Lbs/Kg)
HPS
PSMH
250
24.5/11.1
—
320
—
28.0/12.7
350
—
28.5/12.9
400
28.5/12.9
28.5/12.9
Mounting Hoods
and Reflectors
Pendant
Pendant Cone
Ceiling
Wall
25° Stanchion
90° Stanchion
Standard Dome
30° Angle
Wt. Lbs.
2.25/1.0
2.50/1.1
3.00/1.4
4.00/1.8
3.25/1.5
3.75/1.7
3.50/1.6
3.50/1.6
Globe Refractor, Enclosed
Reflector and Guards
Glass Globe
Globe Guard
12” Glass Refractor
Refractor Guard
Enclosed Reflector
Enclosed Reflector Guard
Wt. Lbs/Kg
7.0/3.2
3.0/1.4
12.0/5.4
4.5/2.0
11.0/5.0
2.0/0.9
Weights are approximate. Add 0.25 lb. for Quartz option.
990
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
PCD2 Series Factory Sealed Hazardous Location Photocontrol
For use in Class I, Division 2, Groups A, B, C, D locations
Maintains Class I, Division 2 rating for Mercmaster III – Low Profile, Mercmaster III, and Mercmaster III – 400 Series Luminaires, Mercmaster LED
Class I, Division 2, Groups A, B, C, D
NEMA 4X
Applications
Materials
• Encapsulated photocontrol provides automatic dusk-to-dawn
lighting control in Class I, Division 2 locations.
• Typical applications include walkways, security areas and any
other outdoor lighting application.
• For use with Mercmaster III – Low Profile, Mercmaster III, and
Mercmaster III – 400 Series Luminaires.
• For remote mounting in FS Boxes.
• Encapsulated with epoxy sealing compound
• FS: aluminum
Lighting
Certifications and Compliances
• UL Standard: 1604 – Hazardous (Classified) Locations
• cULus Recognized
Features
Factory-Installed Photocontrol
Dimensions
Add to fixture catalog after voltage; i.e.: KPWBL1075MTH1.
Mercmaster III wall mounting hood
with photocontrol installed shown
Lighting: Enclosed and Gasketed — Area — HID
• Factory sealed design eliminates the need for an explosionproof
enclosure.
• Can be easily installed in the field.
• Solid state design for performance and reliability.
• Available for 120, 208, 240, or 277 volts.
• 50-400 W HID, incandescent or fluorescent, 50/60 Hz.
• 1000 VA Voltage/Ampere
• Minimum time delay: 15 seconds to eliminate nuisiance tripping.
• Provided with (3) 18AWG stranded leads 6”/152.4 mm in length.
• Will fit through standard 1/2” knockout.
Voltage Range
Suffix Designation
120 V, 50/60 Hz
H1
208 V, 50/60 Hz
H2
240 V, 50/60 Hz
H3
277 V, 50/60 Hz
H4
1.13”
28.7
mm
1.13”
28.7 mm
Photocontrol in FS Cover for Use with FS/FD Box
Supplied with two stainless steel screws. For neoprene gasket, order catalog number FS-GKR-1N.
Voltage Range
Catalog Number
120V, 50/60 Hz
FSKA-PC120D2
208-277V, 50/60 Hz
FSKA-PC247D2
1.375”
34.9
mm
1.375”
34.9 mm
2.56”
65.0
mm
2.56”
65.0 mm
1.13”
28.7 mm
Photocontrol for Field Installation
Max. Current
Catalog Number
120 V, 50/60 Hz
Voltage Range
8.3 Amp
PC120D2
208-277 V, 50/60 Hz
3.5 Amp
34.9 mm
PC247D2
2.56”
65.0 mm
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
1.375”
0.69”
17.5 mm
1.19”
30.2 mm
1.94”
49.2 mm
991
Mercmaster™ III 400 Luminaire Photometric Data
400 W PSMH
Listed for simultaneous exposure to combustible dusts and flammable gases or vapors.
* Photometric data is based on a fixture with
a 400-watt clear Pulse Start Metal Halide lamp
(44,000 lumen).
Lighting: Enclosed and Gasketed — Area — HID
Lighting
Zone
For candlepower values of fixtures with other
PSMH lamps, use the following multipliers: for a 320
W (33,000 lumen) PSMH lamp – .750; for a 350 W
(37,000 lumen) PSMH lamp – .840. For candlepower
values of fixture with guard, multiply by – 0.95.
Lumens
Total Luminaire Efficiency = 92.6%
0-10
118.85
CIE Type - General Diffuse
10-20
488.36
20-30
948.99
30-40
1678.84
Coefficients of Utilization - Zonal Cavity Method
40-50
2714.15
Effective Floor Cavity Reflectance 0.20
50-60
3299.55
% Ceiling Rcc
60-70
3919.47
% Walls
70-80
4497.45
80-90
4892.41
90-100
REPORT NUMBER: KP40PG
Lamps: 400 W Pulse Start Metal Halide with Globe *
Lumens
70
50
30
10
0
0 100100100100 93 93 93 93 80 80 80 68 68 68 57 57 57 51
Zonal Lumen Summary
Zone
80
Rw 70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0
1 86 80 74 69 79 73 68 64 62 58 54 51 48 45 41 39 37 32
% Lamp % Fixture
4803.79
0-30
1556.19
3.5
3.8
2 76 67 59 52 70 61 54 48 51 45 41 42 37 33 33 30 27 22
100-110 4404.56
0-40
3235.03
7.4
7.9
3 68 57 48 41 62 52 44 38 45 37 32 35 30 26 28 24 20 16
110-120 3849.71
0-60
9248.74
21.0
22.7
4 62 49 40 33 56 45 37 30 37 31 26 30 25 21 24 20 16 13
120-130 3078.18
0-90
22558.07
51.3
55.4
5 56 43 34 27 51 40 31 25 33 26 21 27 21 17 21 17 13 10
130-140 1852.83
90-120 13058.07
29.7
32.0
6 51 38 29 23 47 35 27 21 29 23 18 24 18 14 18 14 11
8
140-150
185.86
90-130 16136.25
36.7
39.6
7 47 34 25 20 43 31 24 18 26 20 15 21 16 12 17 12
9
7
150-160
14.88
90-150 18174.93
41.3
44.6
8 44 31 22 17 40 28 21 16 24 17 13 19 14 10 15 11
8
6
160-170
1.78
90-180 18191.71
41.3
44.6
9 41 28 20 15 37 26 18 14 21 15 11 18 13
9 14 10
7
5
170-180
0.12
0-180
92.6
100.0
10 38 25 18 13 35 23 16 12 20 14 10 16 11
8 13
6
4
Zone
40749.78
9
Lumens
Total Luminaire Efficiency = 81.4%
0-10
561.93
CIE Type - Direct
10-20
1748.92
20-30
2859.54
30-40
4018.21
0-180
1.76
Coefficients of Utilization - Zonal Cavity Method
40-50
5254.58
90-270
1.76
Effective Floor Cavity Reflectance 0.20
50-60
5772.38
Diagonal
1.86
60-70
6052.84
70-80
5887.04
80-90
3512.71
90-100
137.17
0-30
5170.39
11.8
14.4
2 74 65 58 51 72 63 57 51 60 54 49 57 52 48 55 51 47 45
100-110
0.00
0-40
9188.60
20.9
25.7
3 66 55 47 40 64 54 46 40 51 44 39 49 43 38 46 42 37 35
110-120
0.00
0-60
20215.55
45.9
56.5
4 60 48 39 32 58 47 39 32 44 37 32 42 36 31 40 35 31 28
120-130
0.00
0-90
35668.14
81.1
99.6
5 55 42 33 27 53 41 33 27 39 32 26 37 31 26 36 30 26 24
130-140
0.00
90-120
137.17
0.3
0.4
6 50 37 29 23 48 36 28 23 35 28 22 33 27 22 32 26 22 20
140-150
0.00
90-130
137.17
0.3
0.4
7 46 33 25 20 44 33 25 19 31 24 19 30 24 19 29 23 19 17
150-160
0.00
90-150
137.17
0.3
0.4
8 43 30 22 17 41 30 22 17 28 22 17 27 21 17 26 21 17 15
160-170
0.00
90-180
137.17
0.3
0.4
9 40 28 20 15 38 27 20 15 26 19 15 25 19 15 24 19 15 13
170-180
0.00
0-180
35805.32
81.4
100.0
10 37 25 18 13 36 25 18 13 24 18 13 23 17 13 22 17 13 12
992
REPORT NUMBER: KP40PST
Lamps: 400 W Pulse Start Metal Halide with
Standard Dome Reflector *
Spacing
Criteria
Plane
% Ceiling Rcc
% Walls
Lumens
70
50
30
10
0
Rw 70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0
0 97 97 97 97 95 95 95 95 90 90 90 86 86 86 83 83 83 81
Zonal Lumen Summary
Zone
80
% Lamp % Fixture
1 84 78 73 68 81 76 71 67 72 69 65 69 66 63 66 63 61 59
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
Mercmaster™ III 400 Luminaire Photometric Data
400 W PSMH
Listed for simultaneous exposure to combustible dusts and flammable gases or vapors.
* Photometric data is based on a fixture with
a 400-watt clear Pulse Start Metal Halide lamp
(44,000 lumen).
Zone
For candlepower values of fixtures with other
PSMH lamps, use the following multipliers: for a 320
W (33,000 lumen) PSMH lamp – .750; for a 350 W
(37,000 lumen) PSMH lamp – .840. For candlepower
values of fixture with guard, multiply by – 0.95.
Lumens
Total Luminaire Efficiency = 76%
0-10
499.96
CIE Type - Direct
10-20
1605.38
20-30
2680.72
30-40
3841.49
0-180
2.28
Coefficients of Utilization - Zonal Cavity Method
40-50
4899.23
90-270
1.92
Effective Floor Cavity Reflectance 0.20
50-60
4819.21
Diagonal
1.84
60-70
4564.58
70-80
4063.65
80-90
3258.13
90-100
2105.14
100-110
762.24
110-120
138.12
0-30
120-130
77.59
130-140
73.07
140-150
150-160
Spacing
Criteria
Plane
% Ceiling Rcc
% Walls
80
70
50
30
Lighting
REPORT NUMBER: KP40PAN
Lamps: 400 W Pulse Start Metal Halide with
30° Angle Dome Reflector *
10
0
Rw 70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0
1 78 72 68 64 75 70 66 62 65 62 59 61 58 56 57 55 53 50
2 69 61 55 49 66 59 53 48 55 50 46 51 47 43 48 44 41 39
Zonal Lumen Summary
Zone
Lumens
% Lamp % Fixture
3 62 52 45 39 59 51 44 38 47 41 37 44 39 35 41 37 33 31
4786.06
10.9
14.3
4 56 46 38 32 54 44 37 31 41 35 30 38 33 29 36 31 28 26
0-40
8627.55
19.6
25.8
5 51 40 33 27 49 39 32 26 36 30 25 34 29 24 32 27 23 21
0-60
18345.99
41.7
54.9
6 47 36 28 23 45 35 28 22 32 26 22 30 25 21 29 24 20 18
25.07
0-90
30232.35
68.7
90.4
7 43 32 25 20 42 31 24 19 29 23 19 27 22 18 26 21 17 16
10.91
90-120
3005.49
6.8
9.0
8 40 29 22 17 39 28 22 17 27 21 16 25 20 16 24 19 15 14
160-170
5.30
90-130
3083.09
7.0
9.2
9 37 26 20 15 36 26 19 15 24 19 15 23 18 14 22 17 14 12
170-180
1.45
90-150
3181.23
7.2
9.5
10 35 24 18 14 34 24 17 13 22 17 13 21 16 13 20 15 12 11
90-180
3198.89
7.3
9.6
0-180
33431.25
76.0
100.0
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
993
Lighting: Enclosed and Gasketed — Area — HID
0 89 89 89 89 86 86 86 86 80 80 80 75 75 75 71 71 71 69
Mercmaster™ III 400 Luminaire Photometric Data
400 W PSMH
Listed for simultaneous exposure to combustible dusts and flammable gases or vapors.
* Photometric data is based on a fixture with
a 400-watt clear Pulse Start Metal Halide lamp
(44,000 lumen).
Lighting: Enclosed and Gasketed — Area — HID
Lighting
Zone
Lumens
For candlepower values of fixtures with other
PSMH lamps, use the following multipliers: for a 320
W (33,000 lumen) PSMH lamp – .750; for a 350 W
(37,000 lumen) PSMH lamp – .840. For candlepower
values of fixture with guard, multiply by – 0.95.
Total Luminaire Efficiency = 78.4%
REPORT NUMBER: KP40PJ5
Lamps: 400 W Pulse Start Metal Halide with
8” Prismatic Glass Refracter - NEMA Type V *
CIE Type - Semi-Direct
0-10
77.24
10-20
575.14
20-30
1061.45
30-40
1581.40
0-180
1.36
40-50
4468.52
90-270
1.40
50-60
4938.88
Diagonal
2.42
60-70
6338.26
70-80
5875.90
80-90
3886.90
90-100
1318.17
0-30
1713.83
3.9
5.0
1 77 71 66 61 73 68 63 59 62 58 54 57 53 50 52 49 47 44
100-110 1872.98
0-40
3295.23
7.5
9.6
2 67 58 50 44 64 55 48 42 50 44 39 45 41 37 41 37 34 31
110-120 1122.17
0-60
12702.64
28.9
36.8
3 59 48 40 33 56 46 38 32 42 35 30 38 32 27 34 29 25 23
120-130
616.83
0-90
28803.69
65.5
83.5
4 53 41 33 26 50 39 31 25 35 29 23 32 26 21 29 24 20 17
130-140
358.56
90-120
4313.33
9.8
12.5
5 48 36 27 21 45 34 26 20 31 24 18 28 22 17 25 20 16 13
140-150
224.03
90-130
4930.15
11.2
14.3
6 44 31 23 17 41 30 22 16 27 20 15 24 18 14 22 17 13 11
150-160
128.38
90-150
5512.75
12.5
16.0
7 40 28 20 14 38 26 19 14 24 17 13 22 16 12 19 14 11
9
160-170
50.79
90-180
5699.61
13.0
16.5
8 37 25 17 12 35 24 17 11 22 15 11 19 14 10 18 13
9
7
170-180
7.69
0-180
34503.3
78.4
100.0
9 34 22 15 10 32 21 15 10 20 13
Spacing
Criteria
Plane
Coefficients of Utilization - Zonal Cavity Method
Effective Floor Cavity Reflectance 0.20
% Floors Rfc
% Ceiling Rcc
Zonal Lumen Summary
Zone
Lumens
% Walls
20
80
70
30
9 30 20 13
9 18 12
8 16 11
8
6
8 16 11
7 15 10
7
5
Total Luminaire Efficiency = 64.2%
0-10
514.26
CIE Type - Direct
10-20
1734.49
20-30
3370.99
30-40
5333.06
0-180
2.32
Coefficients of Utilization - Zonal Cavity Method
40-50
7165.13
90-270
2.32
Effective Floor Cavity Reflectance 0.20
50-60
6195.93
Diagonal
2.04
60-70
2879.28
70-80
921.95
80-90
111.28
REPORT NUMBER: KP40PHB
Lamps: 400 W Pulse Start Metal Halide with
Enclosed Reflector (KPR-4HB) *
Spacing
Criteria
% Floors Rfc
% Ceiling Rcc
Zonal Lumen Summary
Zone
Lumens
0
9 18 12
Lumens
Plane
10
0 90 90 90 90 87 87 87 87 80 80 80 74 74 74 68 68 68 65
% Lamp % Fixture
10 32 20 14
Zone
50
Rw 70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0
% Walls
% Lamp % Fixture
20
80
70
50
30
10
0
Rw 70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0
0 76 76 76 76 75 75 75 75 71 71 71 68 68 68 65 65 65 64
90-100
0.14
0-30
5619.74
12.8
19.9
1 70 67 65 63 69 66 64 62 63 61 60 61 59 58 59 57 56 55
100-110
0.00
0-40
10952.81
24.9
38.8
2 64 59 55 51 62 58 54 50 55 52 49 53 51 48 51 49 47 46
110-120
0.00
0-60
24313.86
55.3
86.1
3 58 51 46 42 56 50 46 42 48 44 41 47 43 40 45 42 40 38
120-130
0.00
0-90
28226.37
64.2
100.0
4 53 45 39 35 51 44 39 35 43 38 34 41 37 34 40 36 33 32
130-140
0.00
90-120
0.14
0.0
0.0
5 48 40 34 30 47 39 34 29 38 33 29 36 32 29 35 31 28 27
140-150
0.00
90-130
0.14
0.0
0.0
6 44 35 29 25 43 35 29 25 34 29 25 32 28 25 31 28 24 23
150-160
0.00
90-150
0.14
0.0
0.0
7 41 32 26 22 39 31 26 22 30 25 22 29 25 21 28 24 21 20
160-170
0.00
90-180
0.14
0.0
0.0
8 37 29 23 19 36 28 23 19 27 22 19 26 22 19 26 22 19 17
170-180
0.00
0-180
28226.50
64.2
100.0
9 35 26 20 17 34 25 20 17 25 20 17 24 20 16 23 19 16 15
10 32 24 18 15 32 23 18 15 23 18 15 22 18 15 21 17 15 13
994
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
LN Series Wellglass Luminaires
Zone 2 and 22
Zone 2 and 22
II 3 GD
ATEX / IEC IP66
Applications
Lighting
Low Profile Ceiling Mount with
Prismatic Globe and Optional Guard
50-200 Watt 25° Stanchion Mount
with Prismatic Globe
50-200 Watt 90° Stanchion Mount
with Prismatic Globe and
Optional Guard
400 Watt Straight Stanchion Mount
with Prismatic Glass Globe and
Optional Guard
Features
• Power supply 230/240 V (+6% - 10%) 50 Hz.
• Instant relighting with auxiliary halogen lamps, depending on
model (lamps not supplied).
• Fast relighting for 70 W and 150 W sodium: 5 to 30 seconds
depending on the duration of the mains power supply failure.
• Connection via terminal block (0.003 x 0.006 in2 /
2 x 4 mm2 max.).
• Superior corrosion-resistance: copperfree die-cast mounting
hoods, ballast housing and guards have a gray epoxy powder
coat, electrostatically applied for complete and uniform
protection.
• Wide choice of light sources: high pressure sodium, metal
halide, mercury vapor and incandescent.
• Six mounting arrangements to suit any lighting layout – pendant,
ceiling, wall bracket, angled or straight stanchion and pendant
cone (for dust applications).
• Hinge has high lip for added safety during installation
and servicing. Hinge and bolt construction assures 360°
compression at all points on ballast housing gasket for positive
sealing. Swing away design of captive bolt and nut simplifies
servicing.
• All fixtures designed to perform in a -40 °F/-40 °C ambient
temperature up to 131 °F/55 °C.
• Standard dome or 30° angle reflectors made of fiberglass
reinforced white polyester. Highly resistant to corrosive
atmospheres and vented to improve fixture cooling
characteristics.
• Fixture housing mounting hoods and guards are die-cast
copperfree aluminum with epoxy powder coat finish.
• All exposed hardware is stainless steel and captive. Stainless
thread inserts in the ballast bodies prevent “freezing” of the
screws that affix guards and reflectors, simplifying removal for
service.
• One-piece ballast housing for each component provides even
heat dissipation for cooler operation and longer ballast life.
• Fixture bodies are provided with two silicone rubber O-Ring
style gaskets that will stay flexible and assure even compression
around their circumference. They easily withstand high
temperatures, moisture, dirt and dust for worry free operation.
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
Standard Materials
• Mounting hoods and ballast bodies: die-cast copperfree (4/10
of 1% max.) aluminum
• Hardware and catch assemblies: stainless steel
• Globe: heat and impact resistant internally fluted glass
• Gasket: high temperature silicon
• Reflector: fiberglass reinforced polyester
• Guards: polyester powder coat finished cast copperfree
aluminum (LN1 and LN2 sizes) or stainless steel (LN3 and LN4
sizes)
Standard Finishes
• Mounting hoods, ballast bodies and guards: epoxy powder coat
finish, electrostatically applied for complete, uniform surface
protection
• Reflectors: white polyester finish
995
Lighting: Enclosed and Gasketed — Area — HID
• Enclosed and gasketed fixtures suitable for use in:
— Marine and wet locations
— Areas where flammable gases, vapors or combustible dusts
are present under conditions defined by the IEC as Zone 2
and 22
— Applications where energy efficient, high lumen output is
required
— Non-hazardous locations where severe weather conditions,
excessive moisture, dirt, dust, corrosive atmosphere or high
ambient temperatures are encountered
• Typical applications include:
— Pulp and paper mills
— Processing plants
— Chemical plants
— Oil refineries
— Foundries
— Manufacturing plants
— Storage areas
— Waste and sewage treatment
— Other areas where dust, water, dirt and rough usage are a
problem
LN Series Wellglass Luminaires
Zone 2 and 22
Zone 2 and 22
II 3 GD
ATEX / IEC IP66
Lighting: Enclosed and Gasketed — Area — HID
Lighting
Certifications and Compliances
•
•
•
•
•
•
Gas: Certification Type LN
— Zone 2
— Conforming to ATEX 94/9/CE: CE
II3 G
— ATEX/IEC Protection: Ex nR II
— Ambient Temperature: 104 °F/40 °C to 131 °F/55 °C
— CE Declaration of Conformity: 50217
— ATEX Certificate: LCIE 08 ATEX 6036X
— IEC Certificate: LCIE Ex 08.003X
— Other Certifications: GOST
Dust: Certification Type LN
— Zone 22
— Conforming to ATEX 94/9/CE: CE
II3 D
— ATEX/IEC Protection: Ex tD A22
— Ambient Temperature: 104 °F/40 °C to 131 °F/55 °C
— CE Declaration of Conformity: 50217
— ATEX Certificate: LCIE 08 ATEX 6036X
— IEC Certificate: LCIE Ex 08.003X
— Other Certifications: GOST
Ex standards :EN / IEC 60079-0; 60079-15; 61241-0; 61241-1
Product standards: EN / IEC 60598-1
EMC standards: EN / IEC 55015; 61547
Other standards: EN / IEC 60529 (IP)
Order using catalog numbering guide below or select catalog number from tables on following pages.
Catalog Numbering Guide for LN Series Luminaires
LN
1
Series:
LN - LN Series
Zone 2, 22
ATEX/IEC Certified
A
Mounting:
A - Pendant
(Rigid
Mounting)
C - Ceiling
D - Pendant Cone
F - Pendant
(Flexible
Mounting)
R - Straight
Stanchion
S - 25° Stanchion
W - Wall
Body Size:
1 - Size 1 (MLBG)
2 - Size 2 (KPB)
3 - Size 3 (KPBR)
4 - Size 4 (KPB400)
996
H
70
A
Lamp Wattage:
70 - 70 W
80 - 80 W
85 - 85 W
Induction only
10 - 100 W
12 - 125 W
15 - 150 W
25 - 250 W
40 - 400 W
Lamp Type:
H - Metal Halide
L - Sodium
M - Mercury Vapor
Q - Induction
Z - Halogen/
Incandescent
G2
XA
Globe:
G2 - Glass Globe
VPGL-2HR
G4 - Glass Globe
VPGL-4HR
Hub Size:
A - M20
2 - 3/4" NPT
3 - 1" NPT
4 - 1-1/4" NPT
5 - 1-1/2" NPT
P
Options:
P - PTFE Coating
Voltage (Magnetic Ballast):
XA - 220 Vac 50 Hz
XJ - 230/240 Vac 50 Hz
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
LN Series Wellglass Luminaires
Zone 2 and 22
Zone 2 and 22
II 3 GD
ATEX / IEC IP66
T Rating for Zone 2 Locations
Not available for Zone 22 locations
Zone 2 T Rating Ambient Temperatures
Lighting
Zone 22 Surface Temperature for
Ambient T° = +131 °F/+55°C
Dust Surface
Cable
+122 °F/+50°C
+131 °F/+55°C
T Rating
T4
T4
T4
235 °F/113 °C
—
100 W HPS
T Rating
T4
T3
T3
289 °F/143 °C
—
100 W Incandescent
T Rating
T4
T3
T3
289 °F/143 °C
—
100 W Halogen
T Rating
T4
T3
T3
289 °F/143 °C
—
125 W Mercury
T Rating
T4
T3
T3
289 °F/143 °C
—
150 W HPS
T Rating
T4
T3
T3
289 °F/143 °C
—
150 W Halide
T Rating
T4
T3
T3
289 °F/143 °C
—
150 W Incandescent
T Rating
T4
T3
T3
289 °F/143 °C
—
150 W Halogen
T Rating
T4
T3
T3
289 °F/143 °C
—
250 W HPS
T Rating
T4
T4
T3
279 °F/137 °C
—
250 W Halide
T Rating
T4
T3
T3
289 °F/143 °C
—
250 W Mercury
T Rating
T4
T3
T3
289 °F/143 °C
—
T Rating
T3
T3
T3
Cable T°
–
183 °F/84 °C
192 °F/89 °C
333 °F/167 °C
192 °F/89 °C
340 °F/171 °C
189 °F/87 °C
340 °F/171 °C
192 °F/89 °C
400 W HPS
400 W Halide
400 W Mercury
T Rating
T3
T3
T3
Cable T°
–
180 °F/82 °C
189 °F/87 °C
T Rating
T3
T3
T3
Cable T°
–
183 °F/84 °C
192 °F/89 °C
“T” Numbers Represent the Maximum Lamp Temperature Locations and Maximum Surface Temperature Under Dust Blanket.
“T”
Number
T1
350
325
T2
T2A
T2B
T2C
T2D
T3
T3A
T3B
T3C
T4
T4A
T5
T6
Temp.
Range
(˚ºF)
664842
619662
574617
538572
502536
448500
421446
394419
358392
331356
322329
277320
250275
214248
187212
185
Temp.
Range
(°C)
351450
326350
301325
281300
261280
231260
216230
201215
181200
166180
161165
136160
121135
101120
86100
85
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
997
Lighting: Enclosed and Gasketed — Area — HID
+104 °F/+40°C
70 W HPS
LN Series Wellglass Luminaires
Zone 2 and 22
Zone 2 and 22
II 3 GD
ATEX / IEC IP66
Lamp
Type
Cable Entry
Lamp
Watts
Lampholder
Weight
Lbs/kg
Volume
(in3/dm3)
Catalog
Number
70
E27
16.31/7.4
2379.93/39
LN1AL702G2XJ
100
E40
19.84/9.0
3356.31/55
LN2AL102G2XJ
150
E40
19.84/9.0
3356.31/55
LN2AL152G2XJ
250
E40
35.27/16.0
4271.66/70
LN3AL252G4XJ
400
E40
41.89/19.0
5199.22/85.2
LN4AL402G4XJ
Lighting
Pendant
Lighting: Enclosed and Gasketed — Area — HID
HPS
1 x 3/4” NPT
Pendant Cone
HPS
1 x 3/4” NPT
70
E27
16.31/7.4
2379.93/39
LN1DL702G2XJ
100
E40
19.84/9.0
3356.31/55
LN2DL102G2XJ
150
E40
19.84/9.0
3356.31/55
LN2DL152G2XJ
250
E40
35.27/16.0
4271.66/70
LN3DL252G4XJ
400
E40
41.89/19.0
5199.22/85.2
LN4DL402G4XJ
Ceiling
HPS
5 x 1” NPT with:
- 4 x 1” NPT fitted plugs
- 2 x 1” NPT-M20 adaptors
- 2 x M20 plugs
70
E27
16.31/7.4
2379.93/39
LN1CL70AG2XJ
100
E40
19.84/9.0
3356.31/55
LN2CL10AG2XJ
150
E40
19.84/9.0
3356.31/55
LN2CL15AG2XJ
250
E40
35.27/16.0
4271.66/70
LN3CL25AG4XJ
400
E40
41.89/19.0
5199.22/85.2
LN4CL40AG4XJ
Wall
HPS
5 x 1” NPT with:
- 4 x 1” NPT fitted plugs
- 2 x 1” NPT-M20 adaptors
- 2 x M20 plugs
70
E27
16.31/7.4
2379.93/39
LN1WL70AG2XJ
100
E40
19.84/9.0
3356.31/55
LN2WL10AG2XJ
150
E40
19.84/9.0
3356.31/55
LN2WL15AG2XJ
250
E40
35.27/16.0
4271.66/70
LN3WL25AG4XJ
400
E40
41.89/19.0
5199.22/85.2
LN4WL40AG4XJ
25° Angled Stanchion
HPS
1 x1- 1/4” NPT
70
E27
16.31/7.4
2379.93/39
LN1SL704G2XJ
100
E40
19.84/9.0
3356.31/55
LN2SL104G2XJ
150
E40
19.84/9.0
3356.31/55
LN2SL154G2XJ
250
E40
35.27/16.0
4271.66/70
LN3SL254G4XJ
400
E40
41.89/19.0
5199.22/85.2
LN4SL404G4XJ
Straight Stanchion
HPS
998
1 x1- 1/4” NPT
70
E27
16.31/7.4
2379.93/39
LN1RL704G2XJ
100
E40
19.84/9.0
3356.31/55
LN2RL104G2XJ
150
E40
19.84/9.0
3356.31/55
LN2RL154G2XJ
250
E40
35.27/16.0
4271.66/70
LN3RL254G4XJ
400
E40
41.89/19.0
5199.22/85.2
LN4RL404G4XJ
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
LN Series Wellglass Luminaires
Zone 2 and 22
Zone 2 and 22
II 3 GD
ATEX / IEC IP66
Lamp Type
Cable Entry
Lamp
Watts
Lampholder
Weight
Lbs/kg
Volume
(in3/dm3)
Catalog
Number
100
E27
16.31/7.4
2379.93/39
LN1AZ102G2
150
E27
16.31/7.4
2379.93/39
LN1AZ152G2
100
E27
16.31/7.4
2379.93/39
LN1DZ102G2
150
E27
16.31/7.4
2379.93/39
LN1DZ152G2
Pendant
Inc./
Halogen
1 x 3/4” NPT
Inc./
Halogen
5 x 1” NPT with:
- 4 x 1” NPT fitted plugs
- 2 x 1” NPT-M20 adaptors
- 2 x M20 plugs
100
E27
16.31/7.4
2379.93/39
LN1CZ10AG2
150
E27
16.31/7.4
2379.93/39
LN1CZ15AG2
5 x 1” NPT with:
- 4 x 1” NPT fitted plugs
- 2 x 1” NPT-M20 adaptors
- 2 x M20 plugs
100
E27
16.31/7.4
2379.93/39
LN1WZ10AG2
150
E27
16.31/7.4
2379.93/39
LN1WZ15AG2
100
E27
16.31/7.4
2379.93/39
LN1SZ104G2
150
E27
16.31/7.4
2379.93/39
LN1SZ154G2
100
E27
16.31/7.4
2379.93/39
LN1RZ104G2
150
E27
16.31/7.4
2379.93/39
LN1RZ154G2
Pendant Cone
Ceiling
Wall
Inc./
Halogen
25° Angled Stanchion
Inc./
Halogen
1 x1- 1/4” NPT
Inc./
Halogen
1 x1- 1/4” NPT
Straight Stanchion
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
999
Lighting: Enclosed and Gasketed — Area — HID
1 x 3/4” NPT
Lighting
Inc./
Halogen
LN Series Wellglass Luminaires
Zone 2 and 22
Zone 2 and 22
II 3 GD
ATEX / IEC IP66
Lamp Type
Lamp
Watts
Lampholder
Weight
Lbs/kg
150
E27
16.31/7.4
250
E40
30.86/14.0
4271.66/70 LN3AM252G4XJ
400
E40
41.89/19.0
5199.22/85.2 LN4AM402G4XJ
150
E27
16.31/7.4
2379.93/39 LN1DM122G2XJ
250
E40
30.86/14.0
4271.66/70 LN3DM252G4XJ
400
E40
41.89/19.0
5199.22/85.2 LN4DM402G4XJ
5 x 1” NPT with:
- 4 x 1” NPT fitted plugs
- 2 x 1” NPT-M20 adaptors
- 2 x M20 plugs
150
E27
16.31/7.4
2379.93/39 LN1CM12AG2XJ
250
E40
30.86/14.0
4271.66/70 LN3CM25AG4XJ
400
E40
41.89/19.0
5199.22/85.2 LN4CM40AG4XJ
5 x 1” NPT with:
- 4 x 1” NPT fitted plugs
- 2 x 1” NPT-M20 adaptors
- 2 x M20 plugs
150
E27
16.31/7.4
2379.93/39 LN1WM12AG2XJ
250
E40
30.86/14.0
4271.66/70 LN3WM25AG4XJ
400
E40
41.89/19.0
5199.22/85.2 LN4WM40AG4XJ
150
E27
16.31/7.4
2379.93/39 LN1SM124G2XJ
250
E40
30.86/14.0
4271.66/70 LN3SM254G4XJ
400
E40
41.89/19.0
5199.22/85.2 LN4SM404G4XJ
150
E27
16.31/7.4
2379.93/39 LN1RM124G2XJ
250
E40
30.86/14.0
4271.66/70 LN3RM254G4XJ
400
E40
41.89/19.0
5199.22/85.2 LN4RM404G4XJ
Cable Entry
Volume
(in3/dm3)
Catalog
Number
Lighting: Enclosed and Gasketed — Area — HID
Lighting
Pendant
MV
1 x 3/4” NPT
2379.93/39 LN1AM122G2XJ
Pendant Cone
MV
1 x 3/4” NPT
Ceiling
MV
Wall
MV
25° Angled Stanchion
MV
1 x 1-1/4” NPT
Straight Stanchion
MV
1000
1 x 1-1/4” NPT
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
LN Series Wellglass Luminaires
Zone 2 and 22
Zone 2 and 22
II 3 GD
ATEX / IEC IP66
Lamp
Type
Cable Entry
Lamp
Watts
Lampholder
Weight
Lbs/kg
Volume
(in3/dm3)
Catalog
Number
150
E40
19.84/9.0
3356.31/55
LN2AH152G2XJ
4271.66/70
LN3AH252G4XJ
Pendant
1 x 3/4” NPT
250
E40
35.27/16.0
400
E40
41.89/19.0
5199.22/85.2 LN4AH402G4XJ
1 x 3/4” NPT
150
E40
19.84/9.0
3356.31/55
LN2DH152G2XJ
250
E40
35.27/16.0
4271.66/70
LN3DH252G4XJ
400
E40
41.89/19.0
5199.22/85.2 LN4DH402G4XJ
Ceiling
MH
5 x 1” NPT with:
- 4 x 1” NPT fitted plugs
- 2 x 1” NPT-M20 adaptors
- 2 x M20 plugs
150
E40
19.84/9.0
3356.31/55
LN2CH15AG2XJ
250
E40
35.27/16.0
4271.66/70
LN3CH25AG4XJ
400
E40
41.89/19.0
5199.22/85.2 LN4CH40AG4XJ
Wall
MH
5 x 1” NPT with:
- 4 x 1” NPT fitted plugs
- 2 x 1” NPT-M20 adaptors
- 2 x M20 plugs
150
E40
19.84/9.0
3356.31/55
LN2WH15AG2XJ
250
E40
35.27/16.0
4271.66/70
LN3WH25AG4XJ
400
E40
41.89/19.0
150
E40
19.84/9.0
5199.22/85.2 LN4WH40AG4XJ
25° Angled Stanchion
MH
1 x 1-1/4” NPT
250
E40
35.27/16.0
400
E40
41.89/19.0
3356.31/55
LN2SH154G2XJ
4271.66/70
LN3SH254G4XJ
5199.22/85.2 LN4SH404G4XJ
Straight Stanchion
MH
1 x 1-1/4” NPT
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
150
E40
19.84/9.0
3356.31/55
LN2RH154G2XJ
250
E40
35.27/16.0
4271.66/70
LN3RH254G4XJ
400
E40
41.89/19.0
5199.22/85.2 LN4RH404G4XJ
1001
Lighting: Enclosed and Gasketed — Area — HID
Pendant Cone
MH
Lighting
MH
LN Series Wellglass Luminaires
Zone 2 and 22
Item
Description
Catalog Number
White Polyester Reflectors — Furnished with stainless steel screws
Lighting
For Globe Fixtures – LN1 and LN2 sizes
Standard Dome
KR2-ST
30° Angle
KR2-AN
For Glass Refractor Fixtures † – LN3 and LN4 sizes
Lighting: Enclosed and Gasketed — Area — HID
Standard Dome
30° Angle
Standard Dome
CMR-4ST
30° Angle
CMR-4AN
Aluminum
KRGU2
Guards
For Globe Fixtures – LN1 and LN2 sizes
For Glass Refractor Fixtures
†
– LN3 and LN4 sizes
Stainless Steel
Globe Guard
KPGU400
Globe Guard
† Fixtures with refractors are not UL Listed when used with reflectors.
1002
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
LN Series Wellglass Luminaires
Zone 2 and 22
Ballast Body with Globe
LN2
LN3
LN4
13.52”/346.0 mm
13.52”/346.0 mm
Fix.
12.68”/322.0 mm
Fix.
12.68”/322.0 mm
Fix.
12.68”/322.0 mm
20.50”/520.7 mm
16.73”/425.0 mm
10.83”/275.0 mm
13.52”/346.0 mm
Fix.
12.68”/322.0 mm
Lighting: Enclosed and Gasketed — Area — HID
11.61”/295.0 mm
13.52”/346.0 mm
Lighting
LN1
Mounting Hoods
Pendant
Pendant Cone
12.06”/306.0 mm
Ceiling
12.06”/306.0 mm
1.17”/
30.0 mm
13.62”/346.0 mm
5.59”/
142.0 mm
12.06”/306.0 mm
1.75”/
45.0 mm
5.00”/
127.0 mm
0.375”/
9.5 mm
Dia. (+DFT)
2.00”/
50.8 mm
Dia. (+DFT)
0.56”/
14.3 mm
Dia. (+DFT)
2.50”/
63.5 mm
Dia. (+DFT)
Wall
17.01”/
432.0 mm
10.94”/
278.0 mm
25° Stanchion
3.38”/
85.8 mm
90° Stanchion
17.23”/438.0 mm
(4) Mounting Holes
0.31”/8.0 mm
4.06”/
103.0 mm
12.05”/
306.0 mm
2.00”/
51.0 mm
15.28”/
388.0 mm
9.79”/249.0 mm
9.25”/
235.0 mm
12.05”/
306.0 mm
12.06”/306.0 mm
7.60”/
193.0 mm
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
1003
LN Series Wellglass Luminaire Photometric Data
Zone 2 and 22
Polar curves for a 1000 lm flux, according to NF C 71-120
Luminaire symbol according to NF C 71-121
Longitudinal
Transverse
High Pressure Sodium
Lighting
70 W HP Sodium
Efficiency 74.6%
Lighting: Enclosed and Gasketed — Area — HID
Degrees
150 W HP Sodium
Efficiency 87.3%
250 W HP Sodium
Efficiency 89.1%
Degrees
Degrees
Degrees
400 W HP Sodium
Efficiency 82.3%
Metal Halide
150 W Metal Halide
Efficiency 82.4%
250 W Metal Halide
Efficiency 96.2%
Degrees
Degrees
400 W Metal Halide
Efficiency 89.8%
Degrees
Incandescent or Halogen
150 W HP Incandescent Halogen
Efficiency 90.6%
Degrees
Mercury Vapor
250 W Mercury Vapor
Efficiency 76%
Degrees
1004
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
Mercmaster™ II HID Luminaires
High Pressure Sodium and Pulse Start Metal Halide. Mogul Base
UNILETS® for Use with Threaded Metal Conduit.
Class I, Division 2, Groups A, B, C, D †
Class II, Division 1 and 2, Groups E, F, G ‡
Class III
Fixtures Outside Type (Salt Water)
Applications
• Superior corrosion-resistance: copperfree aluminum mounting
hoods, ballasts and guards with epoxy powder coat, inside
and out.
• Standard pendant mounting hood for rigid or flexible mounting.
Balanced round design automatically hangs plumb when used
with flexible hanger.
• Positive sealing. Hinge and bolt construction assures 360°
compression at all points on gasket.
• One-piece ballast housing for each component provides even
heat dissipation for cooler operation and longer ballast life.
• Heat barrier isolates capacitor from ballast. Standard non-PCB
biodegradable capacitors installed in separate compartment.
• Mogul socket is furnished with 392 °F/200 °C welded leads,
pre-wired to the ballast.
• Porcelain socket assures trouble-free operation in high ambient
installations.
• Guards protect globes from damage. Keyhole slots allow easy
installation and are secured with stainless steel screws.
• Prismatic glass globes and glass
refractors are standard (plastic refractors also available) and
thread directly into fixture housing. Eliminate glare and provide
uniform light distribution.
• Vented reflectors result in cooler, dirt-free operation, increased
lumen output.
• Reflectors secured to mounting hood with screws (furnished).
• Choice of reflector styles: white porcelain enamel or Fiberglass
reinforced polyester; standard dome or 30° angle.
• Optional photocell provides automatic “on-off” control.
• All Mercmaster mounting hoods have provision for easy field
installation of fuses in fixtures (see fuse kit listings).
Standard Materials
• Mounting hoods, ballast bodies and guards: copperfree (4/10 of
1% max.) aluminum
• Reflectors: fiberglass reinforced polyester
• Globes: 50 W-100 W, threaded prismatic glass; 150 W, 175 W
and 200W, threaded heat-resistant prismatic glass
• Refractors: 50 W to 150 W, heat-resistant prismatic glass and
plastic; 175 W to 200 W, prismatic glass
Standard Finishes
• Mounting hoods, ballast bodies, guards: epoxy powder-coat
finish. Two-coat baked finish, electrostatically applied for
complete uniform surface protection
• Polyester reflectors: natural finish
Options
• Fuses for fixtures. For fuse kits see Electrical Specifications and
Fuse Kits page.
• MH fixtures for Quartz Auxiliary lamps. Relay switch installed
in fixture when specified. Add suffix -MTE to fixture catalog
number for 120 V through 277 V, and suffix -480E to fixture
catalog number for 480 V fixture.
• Smart Hot Restrike emergency option, available for 50 W-150 W
HPS only. Add suffix -SR. See 50 W, 70 W, 100W, 150 W HPS
page.
• Hot Restrike option add suffix -R.
• Smart Starter available for HPS and PSMH. Add suffix -S.
Certifications and Compliances
• UL Standard: UL 1598, UL 1598A, UL 844
• UL Listed: E10444
† For specific Class I suitability of each fixture listed, see Thermal Suitability.
‡ For 175 W and 200 W fixtures, use 12” refractor only for Groups E, F and G. Heat-resistant glass globe supplied with 175 W and 200 W fixtures.
Note: Fixtures equipped with optional photocell or quartz auxilliary lamp do not comply with UL requirements and are not suitable for use in classfied locations.
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
1005
Lighting: Enclosed and Gasketed — Area — HID
Features
Lighting
• Enclosed and gasketed HID lighting fixtures for use in tunnels,
walkways, bridges, storage facilities, processing plants, parking
lots, foundries, manufacturing plants, power plants and other
locations where moisture, dirt, dust or corrosive atmospheres
are encountered.
• Fixtures suited for Class I, Division 2; Class II, Division 1 and
2; and Class III. Suitable for use in wet and outdoor saltwater
locations.
• Wide range of wattages and voltages. Choice of ballasts for 100
W-200 W PSMH; and 50 W-150 W HPS lamps in 120, 208, 240,
277 and 480 voltages.
• Choice of light sources: high pressure sodium and pulse start
metal halide.
• Choice of optical assembles: (1) prismatic globe with or without
guard through 200 W; or (2) Type V closed prismatic glass
refractor through 200 W. (Types II, III and IV also available
through 200 W. Also polycarbonate globes for 100 W max.)
• Choice of mounting hoods: pendant (rigid or flexible), 25° (angle)
stanchion, ceiling and wall mounting.
• Porcelain reflector for standard applications and Fiberglass
reinforced polyester reflector for installations where luminaire is
subject to exceptionally severe corrosive atmospheres.
Mercmaster™ II HID Luminaires
High Pressure Sodium and Pulse Start Metal Halide. Mogul Base
UNILETS® for Use with Threaded Metal Conduit.
Class I, Division 2, Groups A, B, C, D †
Class II, Division 1 and 2, Groups E, F, G ‡
Class III
Fixtures Outside Type (Salt Water)
Lighting: Enclosed and Gasketed — Area — HID
Lighting
Illustrated Features
High Temperature Sockets
Mogul base high temperature socket for
50W through 400W HID lamps.
Aluminum Inner Reflector
Solid aluminum inner reflector improves
photometric efficiency.
Stainless Steel
Latch Assembly
Captive, stainless
steel latch assembly
bolt and nut closes
securely, resists
attack of corrosive
atmospheres.
Swing-away design
simplifies servicing.
"Safety" High
Hinge
Extra-high hinge
provides additional
protection against
accidental
ballast housing
disengagement
during installation
or maintenance.
Hood/Ballast Gasket
Silicone rubber gasket seals out moisture,
dirt and dust.
Epoxy Finish
Ballast housing, hoods and guards are
copperfree aluminum with epoxy powder
coat finish.
Electrical Protection
Ground wire provided to bond mounting
hood to ballast housing. Fiber insulator
protects ballast and capacitor.
Photocell
Installs through knock-out in mounting
hood; provides continuous ON-OFF duskto-dawn control. Fixtures with optional
photocell or quartz auxiliary lamp do not
comply with UL requirements for use in
classified locations.
JB Series Box and
Flexible Hanger
Balanced Round
Design
Pendant fixtures
automatically hang
plumb. Fixtures and
hangers suitable for
Class I, Division 2
applications.
Fuses Mount to Hood Bosses
Two screws secure fuse kit to mounting
boss in any Mercmaster mounting hood.
† For specific Class I suitability of each fixture listed, see Thermal Suitability.
‡ For 175 W and 200 W fixtures, use 12” refractor only for Groups E, F and G. Heat-resistant glass globe supplied with 175 W and 200 W fixtures.
1006
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
Mercmaster™ II HID Luminaires
High Pressure Sodium and Pulse Start Metal Halide. Mogul Base
UNILETS® for Use with Threaded Metal Conduit.
Class I, Division 2, Groups A, B, C, D †
Class II, Division 1 and 2, Groups E, F, G ‡
Class III
Fixtures Outside Type (Salt Water)
The quartz emergency lamp socket is wired to a 120 V tap on the ballast and is therefore
independent of the lighting fixture voltage. No special field wiring is necessary.
Description
Catalog Suffix
For fixture volts of 120, 208, 240 or 277
-MTE
For fixture volts of 480
-480E
The hot lamp restart option provides instant restart of 50, 70, 100 and 150 W HPS lamps after
power outages of up to 10 seconds. The lamps restrike instantly at almost full lumens. For power
interruptions of up to 30 seconds, the restart of the high pressure sodium lamp is also instant but
at less than full lumens. The hot lamp restart accessory does not accelerate cold lamp start up or
starting where the power outage is of a duration which has allowed the HPS lamp to cool.
Encapsulated HPS
Smart Hot Restrike
Ignition Accessory
Additional Advantages of the Smart Hot Restrike:
• Protects against self destruction in the event of failed, missing or broken lamps, or socket or
lead wire failure.
• Prevents “End of Life” lamps from continuous cycling over long periods of time.
• Remains unaffected by stray voltages, moderate overvoltages, as well as undervoltage
conditions.
• Drops into the background during normal lamp operation with exceptionally low insertion loss.
• Fully encapsulated construction assures electrical integrity and mechanical vibration protection.
• UL recognized component.
Description
For fixture watts of 50, 70, 100 or 150 (HPS only)
Accessory Options
Catalog Suffix
-SR
Guards: Guards are die-cast copperfree aluminum with baked epoxy finish to match fixtures. Fixture
supplied with stainless steel mounting screws which thread into stainless steel inserts on fixture housing to
attach guard. To order fixture with guard, add suffix -G to catalog number before adding voltage suffix.
Reflectors: Standard dome and 30° angle polyester reflectors.
Hot Restrike: Instantly restrikes a hot HPS lamp when power is restored after a momentary
outage. Available factory-installed only. To order, add suffix -R to catalog number.
Quartz Emergency Light: When ordered, HPS fixtures will be supplied with a prewired special
DC bayonet base socket to accept a 150W, 120V quartz lamp (not furnished) that automatically
switches on when a power outage occurs. Fixtures ordered with this quartz emergency lamp feature
do NOT comply with requirements for classified areas and should be used only in non-classified
locations. To order, add suffix -E to catalog number and specify if a relay switch is desired.
Photocell and Fuses: Photocontrol.
Smart Starter: Performs as a conventional starter in lamp start-up. Removes itself from circuit at
end of lamp life or if lamp is out of socket. Add suffix -S to catalog number.
Smart Hot Restrike (HPS only): Will immediately restrike HPS lamp when power is restored after
a momentary power interruption. The smart function removes the hot restrike ignitor from the circuit
if the lamp burns out or is removed from the socket. Eliminates starter failures caused by prolonged
operation with cycling or failing lamps. Add suffix -SR to catalog number.
† For specific Class I suitability of each fixture listed, see Thermal Suitability.
‡ For 175 W and 200 W fixtures, use 12” refractor only for Groups E, F and G. Heat-resistant glass globe supplied with 175 W and 200 W fixtures.
* NOTE: Fixtures equipped with quartz emergency light do not comply with UL requirements and are not suitable for use in classified locations.
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
1007
Lighting: Enclosed and Gasketed — Area — HID
HPS Smart Hot Restrike Accessory for HPS Fixtures
Mercmaster fixtures for high pressure sodium lamps can be supplied with a special ignitor (starter
board). It instantly restrikes a hot high pressure sodium lamp when a momentary power interruption
occurs. This special ignitor, supplied in place of the standard ignitor, is a potted solid state device,
totally factory installed. It is not suitable for field installation.
Lighting
Quartz Emergency Light for Pulse Start Metal Halide or High Pressure Sodium Fixtures *
Mercmaster fixtures for or metal halide and high pressure sodium lamps can be supplied with
a socket to accept a 150 W 120 V quartz lamp. This D.C. bayonet base socket is in addition to
the standard lamp socket. In the event of a momentary power interruption, the quartz lamp is
automatically switched on. The single ended quartz lamp remains energized until the HID restrikes
and reaches about 60% output.
Mercmaster™ II HID Luminaire Thermal Suitability
Class I, Division 2, Groups A, B, C, D; Class II, Division 1, Groups E, F, G
UNILETS® for Use with Threaded Metal Conduit.
Lighting
Class I, Division 2, Groups A, B, C, D †
Class II, Division 1 and 2, Groups E, F, G ‡
Class III
Fixtures Outside Type (Salt Water)
The following table shows maximum operating temperatures
of Mercmaster fixtures for Class I, Division 2, in a 104 °F/
40 °C ambient in free air as rated by UL. As shown, the higher the
Temperature Identification Number, the cooler the fixture operates.
Keep this in mind when selecting a fixture for a specific chemical
listed on the Classified Area Suitability pages. Per the NEC. The
temperature marking shown on fixtures shall not exceed the
ignition temperature of the gas to be encountered. To illustrate, a
400W HPS fixture, which has a UL-NEC Temperature Identification
Number of 350 (619-662 °F/326-350/°C) does NOT exceed the
Group D Methane (natural gas) ignition temperature of 1004 °F/
540 °C, and is therefore suitable for use in atmospheres containing
that chemical.
Mercmaster II Thermal Suitability
Watts
Type
Supply
Wire
Temp.
(°F/°C)
50
HPS
194/90
104/40
T3
T3
T3A
T3A
T3B
T3B
T3B
T3B
70
HPS
194/90
104/40
T3
T3
T3A
T3A
T3B
T3B
T3B
T3B
100
HPS
194/90
104/40
T2C
T2C
T3
T3
T3B
T3B
T3B
T3B
150
HPS
194/90
104/40
T2A
T2A
T2B
T2B
➊
➊
➊
T3B
150
PSMH
194/90
104/40
T2B
T2B
T2D
T2D
—
—
—
—
175
PSMH
194/90
104/40
T2B
T2B
T2C
T2C
—
—
—
—
200
PSMH
194/90
104/40
T2
T2
T2B
T2B
—
—
—
—
Lighting: Enclosed and Gasketed — Area — HID
Lamp
Class I, Division 2, Groups A, B, C, D
Class II, Division 1, Groups E, F G
Ambient
Temp.
(°F/°C)
Globe
Globe &
Reflector
8”
Refractor
12”
Refractor
Globe
Globe &
Reflector
8”
Refractor
12”
Refractor
“T” Numbers Represent the Maximum Lamp Temperature for Class I, Division 2 Locations and
Maximum Surface Temperature Under Dust Blanket for Class II, Division 1 Locations.
“T”
Number
T1
350
325
T2
T2A
T2B
T2C
T2D
T3
T3A
T3B
T3C
T4
T4A
T5
T6
Temp.
Range
(˚ºF)
664842
619662
574617
538572
502536
448500
421446
394419
358392
331356
322329
277320
250275
214248
187212
185
Temp
Range
(°C)
351450
326350
301325
281300
261280
231260
216230
201215
181200
166180
161165
136160
121135
101120
86100
85
All HPS fixtures suitable for operation at -40 °F/-40 °C; PSMH at -20 °F/-29 °C.
† For specific Class I suitability of each fixture listed, see Thermal Suitability above.
‡ For 175 W and 200 W fixtures, use 12” refractor only for Groups E, F and G. Heat-resistant glass globe supplied with 175 W and 200 W fixtures.
➊ Pendant, ceiling and wall mount are suitable for groups E and F only with T3A rating. Stanchion mount is suitable for groups E, F and G with a T3B rating.
1008
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
Mercmaster™ II HID Luminaires
50 W, 70 W, 100 W, 150 W HPS
High Power Factor (Min. P.F. 90%). Suitable for Use in Wet Locations. Prismatic Glass Globe or Type V Closed Glass Refractor. Mogul Base Lamps.
Class I, Division 2, Groups A, B, C, D †
Class II, Division 1 and 2, Groups E, F, G ‡
Class III
Fixtures Outside Type (Salt Water)
With Globe,
With 8” Refractor
Lamp
Less Guard
(NEMA V)
Watts
Pendant — One Hub, Rigid or Flexible Mounting
70
100
3/4
LPAL5075 ➌
LPAL5075J ➌
LPAL5075R ➌
1
LPAL5010 ➌
LPAL5010J ➌
LPAL5010R ➌
3/4
LPAL7075 ➍
LPAL7075J ➍
LPAL7075R ➍
1
LPAL7010 ➍
LPAL7010J ➍
LPAL7010R ➍
3/4
LPAL1075 ➍
LPAL1075J ➍
LPAL1075R ➍
1
LPAL1010 ➍
LPAL1010J ➍
LPAL1010R ➍
3/4
LPAL1575 ➍
LPAL1575J ➍
LPAL1575R ➍
1
LPAL1510 ➍
LPAL1510J ➍
LPAL1510R ➍
3/4
LPCL5075 ➌
LPCL5075J ➌
LPCL5075R ➌
1
LPCL5010 ➌
LPCL5010J ➌
LPCL5010R ➌
3/4
LPCL7075 ➍
LPCL7075J ➍
LPCL7075R ➍
1
LPCL7010 ➍
LPCL7010J ➍
LPCL7010R ➍
3/4
LPCL1075 ➍
LPCL1075J ➍
LPCL1075R ➍
With 12” Refractor
Ceiling — Five Hubs, Four Close-Up Plugs
50
70
100
150
1
LPCL1010 ➍
LPCL1010J ➍
LPCL1010R ➍
3/4
LPCL1575 ➍
LPCL1575J ➍
LPCL1575R ➍
1
LPCL1510 ➍
LPCL1510J ➍
LPCL1510R ➍
3/4
LPWBL5075 ➌
LPWBL5075J ➌
LPWBL5075R ➌
1
LPWBL5010 ➌
LPWBL5010J ➌
LPWBL5010R ➌
3/4
LPWBL7075 ➍
LPWBL7075J ➍
LPWBL7075R ➍
1
LPWBL7010 ➍
LPWBL7010J ➍
LPWBL7010R ➍
3/4
LPWBL1075 ➍
LPWBL1075J ➍
LPWBL1075R ➍
1
LPWBL1010 ➍
LPWBL1010J ➍
LPWBL1010R ➍
3/4
LPWBL1575 ➍
LPWBL1575J ➍
LPWBL1575R ➍
1
LPWBL1510 ➍
LPWBL1510J ➍
LPWBL1510R ➍
1-1/4
LPSL50125 ➌
LPSL50125J ➌
LPSL50125R ➌
1-1/2
LPSL50150 ➌
LPSL50150J ➌
LPSL50150R ➌
1-1/4
LPSL70125 ➍
LPSL70125J ➍
LPSL70125R ➍
1-1/2
LPSL70150 ➍
LPSL70150J ➍
LPSL70150R ➍
1-1/4
LPSL10125 ➍
LPSL10125J ➍
LPSL10125R ➍
1-1/2
LPSL10150 ➍
LPSL10150J ➍
LPSL10150R ➍
1-1/4
LPSL15125 ➍
LPSL15125J ➍
LPSL15125R ➍
1-1/2
LPSL15150 ➍
LPSL15150J ➍
LPSL15150R ➍
Wall — Five Hubs, Four Close-Up Plugs
50
70
100
150
25° Stanchion — One Hub
50
70
100
150
† For specific Class I suitability of each fixture listed, see Thermal Suitability.
‡ For 175 W and 200 W fixtures, use 12” refractor only for Groups E, F and G. Heat-resistant glass globe supplied with 175 W and 200 W fixtures.
➊ To order fixture with guard, add suffix -G (before adding voltage suffix).
➋ Furnished with 8” NEMA V refractor — to order with NEMA I or III refractor, change J in the catalog number to J1 or J3.
Add voltage suffix -MTMED for Medium Base, 100W (order as special).
➌ Add voltage suffix -MT for 120, 208, 240 or 277 V.
➍ Add voltage suffix -MT for 120, 208, 240 or 277 V; -480 for 480 V.
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
1009
Lighting: Enclosed and Gasketed — Area — HID
150
With Globe ➊
Lighting
50
Catalog Numbers
With 8” Refractor ➋
Hub Size
(Inches)
Mercmaster™ II HID Luminaires
100 W, 150 W, 175 W, 200 W PSMH
Constant Wattage (Min. P.F. 90%). Suitable for Use in Wet Locations. Prismatic Glass Globe or Type V Closed Glass Refractor. Mogul Base Lamps.
Class I, Division 2, Groups A, B, C, D †
Class II, Division 1 and 2, Groups E, F, G ‡
Class III
Fixtures Outside Type (Salt Water)
Lighting
With Globe,
With 8” Refractor
Lamp
Less Guard
(NEMA V)
Watts
Pendant — One Hub, Rigid or Flexible Mounting
100
150
Lighting: Enclosed and Gasketed — Area — HID
175 ‡
200 ‡
Hub Size
(Inches)
With Globe ➊
Catalog Numbers
With 8” Refractor ➋
With 12” Refractor
3/4
LPAH1075 ➍
LPAH1075J ➍
LPAH1075R ➍
1
LPAH1010 ➍
LPAH1010J ➍
LPAH1010R ➍
3/4
LPAP1575 ➍
LPAP1575J ➍
LPAP1575R ➍
1
LPAP1510 ➍
LPAP1510J ➍
LPAP1510R ➍
3/4
LPAP1775 ➍
LPAP1775J ➍
LPAP1775R ➍
1
LPAP1710 ➍
LPAP1710J ➍
LPAP1710R ➍
3/4
LPAP2075 ➍
LPAP2075J ➍
LPAP2075R ➍
1
LPAP2010 ➍
LPAP2010J ➍
LPAP2010R ➍
3/4
LPCH1075 ➍
LPCH1075J ➍
LPCH1075R ➍
1
LPCH1010 ➍
LPCH1010J ➍
LPCH1010R ➍
3/4
LPCP1575 ➍
LPCP1575J ➍
LPCP1575R ➍
1
LPCP1510 ➍
LPCP1510J ➍
LPCP1510R ➍
3/4
LPCP1775 ➍
LPCP1775J ➍
LPCP1775R ➍
1
LPCP1710 ➍
LPCP1710J ➍
LPCP1710R ➍
3/4
LPCP2075 ➍
LPCP2075J ➍
LPCP2075R ➍
1
LPCP2010 ➍
LPCP2010J ➍
LPCP2010R ➍
3/4
LPWBH1075 ➍
LPWBH1075J ➍
LPWBH1075R ➍
1
LPWBH1010 ➍
LPWBH1010J ➍
LPWBH1010R ➍
3/4
LPWBP1575 ➍
LPWBP1575J ➍
LPWBP1575R ➍
1
LPWBP1510 ➍
LPWBP1510J ➍
LPWBP1510R ➍
3/4
LPWBP1775 ➍
LPWBP1775J ➍
LPWBP1775R ➍
Ceiling — Five Hubs, Four Close-Up Plugs
100
150
175 ‡
200 ‡
Wall — Five Hubs, Four Close-Up Plugs
100
150
175 ‡
200 ‡
1
LPWBP1710 ➍
LPWBP1710J ➍
LPWBP1710R ➍
3/4
LPWBP2075 ➍
LPWBP2075J ➍
LPWBP2075R ➍
1
LPWBP2010 ➍
LPWBP2010J ➍
LPWBP2010R ➍
1-1/4
LPSH1075 ➍
LPSH1075J ➍
LPSH1075R ➍
1-1/2
LPSH1010 ➍
LPSH1010J ➍
LPSH1010R ➍
1-1/4
LPSP15125 ➍
LPSP15125J ➍
LPSP15125R ➍
1-1/2
LPSP15150 ➍
LPSP15150J ➍
LPSP15150R ➍
1-1/4
LPSP17125 ➍
LPSP17125J ➍
LPSP17125R ➍
1-1/2
LPSP17150 ➍
LPSP17150J ➍
LPSP17150R ➍
1-1/4
LPSP20125 ➍
LPSP20125J ➍
LPSP20125R ➍
1-1/2
LPSP20150 ➍
LPSP20150J ➍
LPSP20150R ➍
25° Stanchion — One Hub
100
150
175 ‡
200 ‡
† For specific Class I suitability of each fixture listed, see Thermal Suitability.
‡ For 175 W and 200 W fixtures, use 12” refractor only for Groups E, F and G. Heat-resistant glass globe supplied with 175 W and 200 W fixtures.
➊ To order fixture with guard, add suffix -G (before adding voltage suffix).
➋ Furnished with 8” NEMA V refractor — to order with NEMA I or III refractor, change J in the catalog number to J1 or J3.
Add voltage suffix -MTMED for Medium Base, 100W (order as special).
➌ Add voltage suffix -MT for 120, 208, 240 or 277 V.
➍ Add voltage suffix -MT for 120, 208, 240 or 277 V; -480 for 480 V.
1010
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
Mercmaster™ II HID Luminaires Mounting Hoods and Ballast Bodies
High Pressure Sodium and Pulse Start Metal Halide. Mogul Base
Hoods and Ballast Housings are Copperfree Aluminum (4/10 of 1%).
Class I, Division 2, Groups A, B, C, D †
Class II, Division 1 and 2, Groups E, F, G ‡
Class III
Fixtures Outside Type (Salt Water)
Mounting Hoods
Description
Hub Size (Inches)
Catalog Number
Pendant
Lighting
3/4
LPA-75
1
LPA-100
3/4
LPC-75
1
LPC-100
3/4
LPWB-75
1
LPWB-100
One Hub, Rigid or Flexible Mounting
Ceiling
Wall
Five Hubs, Four Close-Up Plugs
25° Stanchion
1-1/4
LPS-125
1-1/2
LPS-150
One Hub
Mounting Adapter
Permits use of Mercmaster II pendant hood on existing
V-51 and Mercmaster I mounting hoods. Remove
Mercmaster I ballast body from existing mounting hood,
thread in adapter and attach wire to Mercmaster II.
LPAD-1
Mercmaster II Ballast Bodies
Type
Ballast Body Catalog Numbers
Globe/12”
8”
Refractor
Refractor
120V
208V
240V
277V
480V
50
LPB50L
LPBLH50R
-MT
-MT
-MT
-MT
—
Lamp
Watts
Add Voltage Suffixes ➊
High Pressure Sodium
High Power
Factor
(Min. P.F. 90%)
70
LPB70L
LPBLH70R
-MT
-MT
-MT
-MT
-480
100
LPB100L
LPBLH100R
-MT
-MT
-MT
-MT
-480
150
LPB150L
LPBLH150R
-MT
-MT
-MT
-MT
-480
100
LPB100H
LPBH100R
150
LPB150P
LPBP150R
-MT
-MT
-MT
-MT
-480
175
LPB175P
LPBP175R
-MT
-MT
-MT
-MT
-480
200
LPB200P
LPBP200R
-MT
-MT
-MT
-MT
-480
Pulse Start Metal Halide
Constant Wattage
(Min. P.F. 90%)
-MTMED -MTMED -MTMED -MTMED -480MED
† For specific Class I suitability of each fixture listed, see Thermal Suitability.
‡ For 175 W and 200 W fixtures, use 12” refractor only for Groups E, F and G. Heat-resistant glass globe supplied with 175 W and 200 W fixtures.
➊ MT (multi-volt) ballasts can be operated at an input voltage of either 120, 208, 240 or 277 V. 480 ballasts can be operated at input voltage of 480 V.
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
1011
Lighting: Enclosed and Gasketed — Area — HID
Five Hubs, Four Close-Up Plugs
Mercmaster™ II HID Luminaire Accessories
High Pressure Sodium and Pulse Start Metal Halide. Mogul Base
Screws furnished to Fasten Reflectors to Ballast Body. Refractors Thread Directly into Ballast Body.
Description
Catalog Number
Lighting: Enclosed and Gasketed — Area — HID
Lighting
Prismatic Glass Globes
Clear Heat-Resistant
VPGL-2HR
Amber
VPGL-2AM
Blue
VPGL-2BL
Green
VPGL-2GR
Red
VPGL-2RE
Coated Prismatic Tuff-Skin® Glass Globes
For use in areas where fixture is
subject to extreme thermal shock
Clear Heat-Resistant
VPGL-2HRT
Polycarbonate Globes – Impact-Resistant ➊
Use 100W Lamp max.; do not use in
ambients exceeding 77 °F/25 °C
Light
Distribution
IES/NECA
Distribution Curves
Clear
VPGL-2PL
Amber
VPGL-2AMPL
Green
VPGL-2GRPL
Red
VPGL-2REPL
8” Glass
(50-200 W ➊)
12” Glass
(50-200 W ➊)
12” Polycarbonate
(50-175 W ➋)
NEMA I
LPG-R1
—
—
NEMA II
—
LPRF-2CG
LPRF-2CP
NEMA III
LPG-R3
—
LPRF-3CP
NEMA IV
—
—
LPRF-4CP
NEMA V
LPG-R5
LPRF-5CG
LPRF-5CP
Closed Prismatic Refractors — 50 W-200 W ➊
8” Refractor
12” Refractor
➊ Polycarbonate globes are shatter-resistant – for use in processing plants, canneries, dairies, bakeries or anywhere broken glass would prove a hazard. Ideally
suited for areas where vandalism, high replacement and high maintenance costs are a problem. Do not use in ambients exceeding 77 °F/25 °C. For burning in
vertical base-up positions only.
Registered trademark of Thomas Manufacturing Corporation, Parkton, Md. It is recommended that guards be used with these globes.
➊ 150 W max. for HPS.
➋ 100 W max. for MH.
1012
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
Mercmaster™ II HID Luminaire Accessories and Weights
High Pressure Sodium and Pulse Start Metal Halide. Mogul Base
Screws furnished to Fasten Reflectors to Ballast Body. Refractors Thread Directly into Ballast Body.
Description
Catalog Number
Guard
KGU2
Guard for Glass Globe
Lighting
Steel Guards for 8” and 12” Refractors
LPRG2
Guard for 12” Refractor
LPBG12
3 machine screws furnished
LPRG-2
LPBG-12
Polyester Reflectors
Standard Dome
Standard Dome
KR2-ST
30° Angle
KR2-AN
30° Angle
Replacement Gaskets — Silicone Rubber
Globe and 12” Refractor Gasket
VPGL-GK
8” Refractor Gasket
KRF-GK
Photocell (Hazardous)
120 Volt
PC120D2
208 thru 277 Volt
PC247D2
Mounting Hood Weights
Type
Weight (Lbs/Kg)
Type
Weight (Lbs/Kg)
Pendant
3/1.4
Wall
5/2.3
Ceiling
5/2.3
Stanchion
4/1.8
Reflectors and Refractors — Weight includes globe and guard
Watts
HPS
50, 70
14
—
100
15
15
150
16
175
—
200
PSMH
Catalog
Wt. Lbs/Kg
Number
Standard Dome Reflector
Catalog
Wt. Lbs/Kg
Number
30° Angle Reflector
LPG-R1
13/5.9
—
5.25/2.4
LPG-R3
13/5.9
16
5.25/2.4
LPG-R5
13/5.9
2.5/1.1
KR2-AN
Catalog
Wt. Lbs/Kg
Number
12” Refractor
5.25/2.4
2.5/1.1
KR2-ST
Catalog
Wt. Lbs/Kg
Number
8” Refractor
LPRF-5CG
18
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
1013
Lighting: Enclosed and Gasketed — Area — HID
Guard for 8” Refractor
Mercmaster™ II HID Luminaire Electrical Specifications and Fuse Kits
High Pressure Sodium and Pulse Start Metal Halide. Mogul Base
UNILETS® for Use with Threaded Metal Conduit.
Class I, Division 2, Groups A, B, C, D †
Class II, Division 1 and 2, Groups E, F, G ‡
Class III
Fixtures Outside Type (Salt Water)
Fuse Kit
Lighting: Enclosed and Gasketed — Area — HID
Lighting
Electrical Specifications
Line
Type of
Starting
Voltage
Ballast
Amps
50 Watt High Pressure Sodium
120
HX-HPF
0.58
208
HX-HPF
0.35
240
HX-HPF
0.31
277
HX-HPF
0.25
70 Watt High Pressure Sodium
120
HX-HPF
0.90
208
HX-HPF
0.50
240
HX-HPF
0.44
277
HX-HPF
0.35
480
HX-HPF
0.21
100 Watt High Pressure Sodium
120
HX-HPF
1.30
208
HX-HPF
0.76
240
HX-HPF
0.66
277
HX-HPF
0.60
480
HX-HPF
0.33
150 Watt High Pressure Sodium
120
HX-HPF
2.00
208
HX-HPF
1.15
240
HX-HPF
1.00
277
HX-HPF
0.85
480
HX-HPF
0.50
100 Watt Pulse Start Metal Halide
120
HX-HPF
1.20
208
HX-HPF
0.70
240
HX-HPF
0.61
277
HX-HPF
0.55
480
HX-HPF
0.30
150 Watt Pulse Start Metal Halide
120
HX-HPF
1.75
208
HX-HPF
1.30
240
HX-HPF
0.85
277
HX-HPF
0.77
480
C.W.A.
0.45
175 Watt Pulse Start Metal Halide
120
C.W.A.
0.90
208
C.W.A.
0.50
240
C.W.A.
0.35
277
C.W.A.
0.30
480
C.W.A.
0.25
200 Watt Pulse Start Metal Halide
120
C.W.A.
2.10
208
C.W.A.
1.15
240
C.W.A.
1.10
277
C.W.A.
.75
480
C.W.A.
.58
Operating
Amps
Total
Watts
0.58
0.33
0.29
0.25
64
64
64
64
0.82
0.48
0.41
0.36
0.21
94
94
94
94
94
1.15
0.67
0.60
0.52
0.31
130
130
130
130
135
1.70
0.95
0.85
0.72
0.47
188
188
188
188
189
1.15
0.70
0.58
0.50
0.35
130
130
130
130
140
1.60
1.00
0.80
0.70
0.42
188
188
188
188
185
1.78
1.08
0.89
0.76
0.50
199
199
199
199
213
2.00
1.25
1.00
.85
.50
238
238
238
238
237
Order fuses as a separate item by catalog number from right columns.
Lamp
Watts
50
70
100
150
175
200
Volts
120
208
240
277
120
208
240
277
480
120
208
240
277
480
120
208
240
277
480
120
208
240
277
480
120
208
240
277
480
Fuse Quantity
Required
1
2
2
1
1
2
2
1
2
1
2
2
1
2
1
2
2
1
2
1
2
2
1
2
1
2
2
1
2
Fuse Kit Catalog Number
HPS
PSMH
F5
—
F3
—
F3
—
F2
—
F5
—
F3
—
F3
—
F2
—
F2
—
F8
F6
F5
F4
F5
F3
F3
F3
F3
F2
F10
F10
F5
F5
F5
F5
F5
F4
F3
F3
—
F5
—
F3
—
F3
—
F2
—
F2
—
F9
—
F6
—
F5
—
F4
—
F2
Fuses are filled with non-combustible granular material.
Fuse Kit includes fuse, fuse block, wire, mounting screws
and connectors. All mounting hoods have provisions
for easy field installation of fuses in fixtures.
† For specific Class I suitability of each fixture listed, see Thermal Suitability.
‡ For 175 W and 200 W fixtures, use 12” refractor only for Groups E, F and G. Heat-resistant glass globe supplied with 175 W and 200 W fixtures.
1014
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
Mercmaster™ II HID Luminaire Dimensions
High Pressure Sodium and Pulse Start Metal Halide. Mogul Base
UNILETS® for Use with Threaded Metal Conduit.
Lighting
25° Angle Stanchion Mount
Ceiling Mount
Wall Mount
Fixture with 8” Refractor
Fixture with Guard and Polyester Reflector
Fixture with 12” Refractor
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
Lighting: Enclosed and Gasketed — Area — HID
Pendant Mount
1015
Mercmaster™ II HID Luminaire Photometric Data
150 W HPS
UNILETS® for Use with Threaded Metal Conduit.
* Photometric data is based on fixtures with
150-watt clear High Pressure Sodium lamp
(16,000 lumen).
Total Luminaire Efficiency = 86.1%
CIE Type - Semi-Direct
Lighting
Plane
Spacing
Criteria
0-180
2.82
90-270
2.82
Diagonal
2.82
For candlepower values of fixtures with other
HPS lamps, use the following multipliers; for
100 W (9,500 lumen) HPS lamp – 0.594; for 70 W
(6,400 lumen) HPS lamp – 0.40; for 50 W (4,000
lumen) HPS lamp – 0.25. For candlepower
values of fixture with guard, multiply by 0.95.
REPORT NUMBER: LP15LGG
150 W High Pressure Sodium fixture with Globe only *
Coefficients of Utilization - Zonal Cavity Method
Effective Floor Cavity Reflectance 0.20
% Ceiling Rcc
Lighting: Enclosed and Gasketed — Area — HID
% Walls Rw
Zone
0-10
10-20
20-30
30-40
40-50
50-60
60-70
70-80
80-90
90-100
100-110
0
1
2
3
4
5
6
7
8
9
10
Lumens
50.74
164.55
310.47
611.05
961.13
1308.18
1542.35
1716.10
1799.18
1802.19
1676.86
80
70
441.46
9.61
3.33
0.74
0.00
0.00
Total Luminaire Efficiency = 73.6%
CIE Type - Direct
Plane
Spacing
Criteria
0-180
1.46
90-270
1.46
Diagonal
1.68
Lumens
266.98
799.41
1337.05
1732.06
2067.60
2317.60
2210.81
866.77
145.09
14.46
8.75
7.93
120-130
130-140
140-150
150-160
160-170
170-180
4.51
2.16
0.48
0.00
0.00
0.00
1016
10
0
30
10
70
50
30
10
50
30
10
50
30
10
50
30
10
0
95
81
71
64
57
52
48
44
40
38
35
95
74
62
52
45
40
35
31
28
25
23
95
69
54
44
36
31
26
23
20
18
16
95
64
47
37
30
24
20
17
15
13
11
89
75
65
58
53
48
44
40
37
35
32
89
69
57
48
42
37
32
29
26
24
22
89
64
50
41
34
29
25
21
19
17
15
89
59
44
34
28
23
19
16
14
12
11
77
59
49
41
35
31
27
24
22
20
18
77
55
43
35
29
24
21
18
16
14
13
77
51
38
30
24
19
16
14
12
10
9
67
50
41
34
29
26
23
20
18
17
15
67
47
36
29
24
20
17
15
13
12
11
67
44
32
25
20
16
13
11
10
8
7
57
42
33
28
24
21
18
16
15
14
13
57
39
30
24
19
16
14
12
11
10
9
57
37
27
20
16
13
11
9
8
7
6
53
33
23
17
13
10
8
7
6
5
4
Zonal Lumen Summary
Zone
0-30
0-40
0-60
0-90
Lumens
525.75
1136.81
3406.12
8463.75
% Lamp
3.3
7.1
21.3
52.9
% Fixture
3.8
8.3
24.7
61.4
Zone
90-120
90-130
90-150
90-180
0-180
Lumens
4858.16
5299.62
5312.56
5313.30
13777.05
% Lamp
30.4
33.1
33.2
33.2
86.1
% Fixture
35.3
38.5
38.5
38.6
100.0
REPORT NUMBER: LP15LST
150 W High Pressure Sodium fixture with Standard Dome Reflector *
Coefficients of Utilization - Zonal Cavity Method
Effective Floor Cavity Reflectance 0.20
% Ceiling Rcc
% Walls Rw
Zone
0-10
10-20
20-30
30-40
40-50
50-60
60-70
70-80
80-90
90-100
100-110
110-120
30
50
110-120 1379.11
120-130
130-140
140-150
150-160
160-170
170-180
50
70
0
1
2
3
4
5
6
7
8
9
10
80
70
50
30
10
0
70
50
30
10
70
50
30
10
50
30
10
50
30
10
50
30
10
0
88
79
71
64
58
53
49
45
42
39
36
88
76
65
56
49
43
38
34
31
28
26
88
72
59
49
42
36
31
27
24
22
20
88
69
55
44
36
31
26
23
20
18
16
86
77
69
62
57
52
47
44
40
38
35
86
74
63
55
48
42
38
34
31
28
26
86
71
58
49
41
35
31
27
24
22
20
86
68
54
44
36
30
26
23
20
18
16
82
71
61
52
46
40
36
33
30
27
25
82
68
57
47
40
35
30
27
24
21
19
82
66
53
43
36
30
26
22
20
17
16
78
68
58
50
44
39
35
31
29
26
24
78
66
55
46
39
34
30
26
23
21
19
78
64
52
42
35
30
25
22
19
17
16
75
65
56
48
42
38
34
30
28
25
23
75
64
53
45
38
33
29
26
23
21
19
75
62
50
41
35
29
25
22
19
17
15
73
60
49
40
33
28
24
20
18
16
14
Zonal Lumen Summary
Zone
0-30
0-40
0-60
0-90
Lumens
2403.44
4135.50
8520.70
11743.37
% Lamp
15.0
25.8
53.3
73.4
% Fixture
20.4
35.1
72.3
99.7
Zone
90-120
90-130
90-150
90-180
0-180
Lumens
31.14
35.65
38.29
38.29
11781.65
% Lamp
0.2
0.2
0.2
0.3
73.6
% Fixture
0.3
0.3
0.3
0.3
100.0
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
Mercmaster™ II HID Luminaire Photometric Data
150 W HPS
UNILETS® for Use with Threaded Metal Conduit.
* Photometric data is based on fixtures with
150-watt clear High Pressure Sodium lamp
(16,000 lumen).
Total Luminaire Efficiency = 73.1%
CIE Type - Direct
Plane
Spacing
Criteria
2.06
90-270
1.58
Diagonal
1.62
REPORT NUMBER: LP15LAN
150 W High Pressure Sodium fixture with 30° Angle Dome Reflector *
Coefficients of Utilization - Zonal Cavity Method
Effective Floor Cavity Reflectance 0.20
% Ceiling Rcc
% Walls Rw
Lumens
222.62
664.60
1084.32
1536.55
1771.90
1771.51
1668.93
1422.36
994.54
432.23
104.58
20.99
120-130
130-140
140-150
150-160
160-170
170-180
1.21
0.04
0.00
0.00
0.00
0.00
Total Luminaire Efficiency = 81.1%
CIE Type - Semi-Direct
Plane
Spacing
Criteria
0-180
1.98
90-270
1.98
Diagonal
3.40
0
1
2
3
4
5
6
7
8
9
10
Lumens
72.83
222.26
380.73
621.11
852.53
1765.29
3192.58
2366.61
1230.65
450.14
712.41
499.15
120-130
130-140
140-150
150-160
160-170
170-180
323.44
185.00
81.31
21.08
2.81
0.00
70
50
30
10
0
70
50
30
10
70
50
30
10
50
30
10
50
30
10
50
30
10
0
86
76
68
61
55
50
46
43
40
37
35
86
71
60
52
45
40
36
32
29
26
24
86
67
54
45
38
33
28
25
22
20
18
86
63
49
39
32
27
23
20
18
16
14
84
73
65
59
53
49
45
41
38
36
33
84
69
58
50
44
39
35
31
28
26
24
84
65
53
44
37
32
28
25
22
20
18
84
62
48
39
32
27
23
20
17
16
14
79
65
55
48
42
37
33
30
27
25
23
79
62
50
42
36
31
27
24
21
19
17
79
59
46
37
31
26
22
19
17
15
14
75
62
52
45
39
35
31
28
26
24
22
75
59
48
40
34
30
26
23
21
19
17
75
57
45
36
30
25
22
19
17
15
13
71
58
49
43
37
33
30
27
25
23
21
71
56
46
39
33
29
25
22
20
18
16
71
54
43
35
29
25
21
19
16
15
13
70
52
41
33
27
23
20
17
15
13
12
Zonal Lumen Summary
Zone
0-30
0-40
0-60
0-90
Lumens
1971.54
3508.09
7051.50
11137.33
% Lamp
12.3
21.9
44.1
69.6
% Fixture
16.9
30.0
60.3
95.2
Zone
90-120
90-130
90-150
90-180
0-180
Lumens
557.80
559.01
559.04
559.04
11696.38
% Lamp
3.5
3.5
3.5
3.5
73.1
% Fixture
4.8
4.8
4.8
4.8
100.0
REPORT NUMBER: LP15LJ
150 W High Pressure Sodium fixture with
8” Prismatic Glass Reractor - NEMA Type V *
Coefficients of Utilization - Zonal Cavity Method
Effective Floor Cavity Reflectance 0.20
% Ceiling Rcc
% Walls Rw
Zone
0-10
10-20
20-30
30-40
40-50
50-60
60-70
70-80
80-90
90-100
100-110
110-120
80
0
1
2
3
4
5
6
7
8
9
10
80
70
50
30
10
0
70
50
30
10
70
50
30
10
50
30
10
50
30
10
50
30
10
0
93
80
69
61
54
49
45
41
38
35
33
93
73
59
49
42
36
32
28
25
23
21
93
68
51
40
32
27
23
20
17
15
14
93
63
45
33
25
20
16
14
12
10
9
89
76
65
57
51
46
42
38
36
33
31
89
70
56
47
40
34
30
27
24
22
20
89
65
49
38
31
26
22
19
16
15
13
89
61
43
32
24
19
16
13
11
10
9
82
64
51
42
35
31
27
24
22
20
18
82
60
45
35
28
23
20
17
15
13
12
82
56
40
29
22
18
14
12
10
9
8
76
58
46
38
32
27
24
24
19
18
16
76
55
41
32
26
21
18
15
14
12
11
76
52
37
27
21
16
13
11
9
8
7
70
53
41
34
28
24
21
19
17
16
15
70
50
37
29
23
19
16
14
12
11
10
70
48
34
25
19
15
12
10
8
7
6
67
45
31
22
16
12
10
8
6
5
5
Zonal Lumen Summary
Zone
0-30
0-40
0-60
0-90
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
Lumens
675.83
1296.93
3914.76
10704.60
% Lamp
4.2
8.1
24.5
66.9
% Fixture
5.2
10.0
30.2
82.5
Zone
90-120
90-130
90-150
90-180
0-180
Lumens
1661.70
1985.14
2251.45
2275.34
12979.94
% Lamp
10.4
12.4
14.1
14.2
81.1
% Fixture
12.8
15.3
15.3
17.5
100.0
1017
Lighting: Enclosed and Gasketed — Area — HID
Zone
0-10
10-20
20-30
30-40
40-50
50-60
60-70
70-80
80-90
90-100
100-110
110-120
Lighting
0-180
For candlepower values of fixtures with other
HPS lamps, use the following multipliers; for
100 W (9,500 lumen) HPS lamp – 0.594; for 70 W
(6,400 lumen) HPS lamp – 0.40; for 50 W (4,000
lumen) HPS lamp – 0.25. For candlepower
values of fixture with guard, multiply by 0.95.
Mercmaster™ II HID Luminaire Photometric Data
175 W PSMH
UNILETS® for Use with Threaded Metal Conduit.
* Photometric data is based on fixtures with
175-watt clear Pulse Start Metal Halide lamp
(17,500 lumen).
Total Luminaire Efficiency = 75.4%
CIE Type - General Diffuse
Lighting
Plane
Spacing
Criteria
0-180
n/a
90-270
n/a
Diagonal
n/a
For candlepower values of fixtures with other
PSMH lamps, use the following multipliers:
for 250 W (23,750 lumen) PSMH lamp – 1.36;
for 100 W (8,500 lumen) PSMH lamp – 0.49.
For candlepower values of fixture with guard,
multiply by 0.95.
REPORT NUMBER: LP17PGG
175 W Pulse Start Metal Halide fixture with Globe only *
Coefficients of Utilization - Zonal Cavity Method
Effective Floor Cavity Reflectance 0.20
% Ceiling Rcc
Lighting: Enclosed and Gasketed — Area — HID
% Walls
Zone
0-10
10-20
20-30
30-40
40-50
50-60
60-70
70-80
80-90
90-100
100-110
Lumens
42.67
151.27
305.99
587.79
880.58
1114.51
1306.71
1568.03
1720.24
1797.50
1750.20
110-120
1559.14
120-130
130-140
140-150
150-160
160-170
170-180
391.09
7.81
3.19
0.61
0.18
0.00
Total Luminaire Efficiency = 63.8%
CIE Type - Direct
Plane
Spacing
Criteria
0-180
1.50
90-270
1.50
Diagonal
1.66
0
1
2
3
4
5
6
7
8
9
10
Lumens
271.72
817.50
1392.53
1749.97
2044.83
2121.25
1862.42
720.46
141.89
14.66
8.28
9.57
120-130
130-140
140-150
150-160
160-170
170-180
5.69
3.14
2.17
1.71
1.70
0.36
1018
70
50
30
10
0
70
50
30
10
70
50
30
10
50
30
10
50
30
10
50
30
10
0
82
70
62
55
50
46
42
38
35
33
31
82
65
54
46
40
35
31
27
25
22
20
82
60
47
38
32
27
23
20
18
16
14
82
55
42
33
26
22
18
15
13
12
10
77
65
57
51
46
42
38
35
32
30
28
77
60
50
42
37
32
28
25
23
21
19
77
56
44
36
30
25
22
19
17
15
13
77
52
39
30
24
20
17
14
12
11
9
66
51
42
35
31
27
24
21
19
17
16
66
47
37
30
25
21
18
16
14
13
11
66
44
33
26
21
17
14
12
10
9
8
57
42
35
29
25
22
20
18
16
14
13
57
40
31
25
21
17
15
13
12
10
9
57
37
28
21
17
14
12
10
9
7
7
48
35
28
23
20
17
15
14
13
12
11
48
33
25
20
16
14
12
10
9
8
7
48
31
22
17
13
11
9
8
7
6
5
44
27
19
14
11
8
7
6
5
4
3
Zonal Lumen Summary
Zone
0-30
0-40
0-60
0-90
Lumens
499.93
1087.72
3082.80
7677.78
% Lamp
2.9
6.2
17.6
43.9
% Fixture
3.8
8.2
23.4
58.2
Zone
90-120
90-130
90-150
90-180
0-180
Lumens
5106.84
5497.93
5508.93
5509.71
13187.48.
% Lamp
29.2
31.4
31.5
31.5
75.4
% Fixture
38.7
41.7
41.7
41.8
100.0
REPORT NUMBER: LP17PST
175 W Pulse Start Metal Halide fixture with Standard Dome Reflector *
Coefficients of Utilization - Zonal Cavity Method
Effective Floor Cavity Reflectance 0.20
% Ceiling Rcc
% Walls
Zone
0-10
10-20
20-30
30-40
40-50
50-60
60-70
70-80
80-90
90-100
100-110
110-120
Rw
80
Rw
0
1
2
3
4
5
6
7
8
9
10
80
70
50
30
10
0
70
50
30
10
70
50
30
10
50
30
10
50
30
10
50
30
10
0
76
69
62
56
51
47
43
40
37
34
32
76
66
57
49
43
38
34
31
28
25
23
76
63
52
44
37
32
28
25
22
20
18
76
61
48
39
33
28
24
21
18
16
15
74
67
61
55
50
45
42
39
36
33
31
74
65
56
48
42
37
33
30
27
25
23
74
62
51
43
37
32
28
25
22
20
18
74
60
48
39
33
28
24
21
18
16
15
71
62
53
46
41
36
32
29
26
24
22
71
60
50
42
36
31
27
24
22
19
18
71
58
47
38
32
27
23
20
18
16
14
68
59
51
45
39
35
31
28
26
23
22
68
57
48
41
35
30
27
24
21
19
17
68
56
46
38
32
27
23
20
18
16
14
65
57
49
43
38
33
30
27
25
23
21
65
55
47
40
34
30
26
23
21
19
17
65
54
45
37
31
27
23
20
18
16
14
64
53
43
35
30
25
22
19
16
15
13
Zonal Lumen Summary
Zone
0-30
0-40
0-60
0-90
Lumens
2481.75
4231.72
8397.80
11122.57
% Lamp
14.2
24.2
48.0
63.6
% Fixture
22.2
37.9
75.2
99.6
Zone
90-120
90-130
90-150
90-180
0-180
Lumens
32.51
38.20
43.51
47.28
11169.85
% Lamp
0.2
0.2
0.2
0.3
63.8
% Fixture
0.3
0.3
0.3
0.4
100.0
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
Mercmaster™ II HID Luminaire Photometric Data
175 W PSMH
UNILETS® for Use with Threaded Metal Conduit.
* Photometric data is based on fixtures with
175-watt clear Pulse Start Metal Halide lamp
(17,500 lumen).
Total Luminaire Efficiency = 61.6%
CIE Type - Direct
Plane
Spacing
Criteria
2.02
90-270
1.62
Diagonal
1.58
REPORT NUMBER: LP17PAN
175 W Pulse Start Metal Halide fixture with 30° Angle Dome Reflector *
Coefficients of Utilization - Zonal Cavity Method
Effective Floor Cavity Reflectance 0.20
% Ceiling Rcc
% Walls
Lumens
221.01
674.48
1111.79
1519.14
1697.13
1644.77
1457.83
1248.84
814.94
280.33
87.54
16.66
120-130
130-140
140-150
150-160
160-170
170-180
1.25
0.06
0.06
0.00
0.00
0.00
Total Luminaire Efficiency = 73.9%
CIE Type - Semi-Direct
Plane
Spacing
Criteria
0-180
2.08
90-270
2.08
Diagonal
3.78
0
1
2
3
4
5
6
7
8
9
10
Lumens
58.60
179.87
316.74
543.99
726.99
1445.41
3661.34
2432.42
1351.63
477.79
717.26
474.07
120-130
130-140
140-150
150-160
160-170
170-180
293.44
163.08
70.40
18.48
2.58
0.00
70
50
30
10
0
70
50
30
10
70
50
30
10
50
30
10
50
30
10
50
30
10
0
73
64
58
52
47
43
40
37
34
32
30
73
61
52
45
39
34
31
28
25
23
21
73
57
46
39
33
28
25
22
20
18
16
73
54
42
34
28
24
20
18
16
14
13
71
62
56
50
46
42
38
35
33
31
29
71
59
50
43
38
34
30
27
25
23
21
71
56
45
38
32
28
24
22
19
17
16
71
53
42
34
28
24
20
18
16
14
12
67
56
47
41
36
32
29
26
24
22
20
67
53
44
36
31
27
24
21
19
17
15
67
51
40
33
27
23
20
17
15
14
12
64
53
45
39
34
30
27
25
23
21
19
64
51
42
35
30
26
23
20
18
17
15
64
49
39
32
27
23
20
17
15
13
12
61
50
43
37
33
29
26
24
22
20
18
61
49
40
34
29
25
22
20
18
16
15
61
47
38
31
26
22
19
17
15
13
12
59
45
36
29
24
21
18
15
14
12
11
Zonal Lumen Summary
Zone
0-30
0-40
0-60
0-90
Lumens
2007.28
3526.41
6868.32
10389.94
% Lamp
11.5
20.2
39.2
59.4
% Fixture
18.6
32.7
63.7
96.4
Zone
90-120
90-130
90-150
90-180
0-180
Lumens
384.53
385.77
385.89
385.89
10775.83
% Lamp
2.2
2.2
2.2
2.2
61.6
% Fixture
3.6
3.6
3.6
3.6
100.0
REPORT NUMBER: LP17PJ
175 W Pulse Start Metal Halide fixture with Globe and
8” Prismatic Glass Reractor - NEMA Type V *
Coefficients of Utilization - Zonal Cavity Method
Effective Floor Cavity Reflectance 0.20
% Ceiling Rcc
% Walls
Zone
0-10
10-20
20-30
30-40
40-50
50-60
60-70
70-80
80-90
90-100
100-110
110-120
Rw
80
Rw
0
1
2
3
4
5
6
7
8
9
10
80
70
50
30
10
0
70
50
30
10
70
50
30
10
50
30
10
50
30
10
50
30
10
0
85
72
62
55
49
44
40
37
34
31
29
85
66
53
44
37
32
28
25
22
20
18
85
61
46
35
28
23
20
17
15
13
12
85
56
39
29
22
17
14
12
10
8
7
82
68
59
51
46
41
37
34
32
30
28
82
63
51
41
35
30
26
23
21
19
18
82
58
44
34
27
22
19
16
14
13
11
82
54
38
28
21
16
13
11
9
8
7
75
57
46
37
31
27
24
21
19
17
16
75
54
40
31
24
20
17
15
13
11
10
75
50
35
25
19
15
12
10
8
7
6
69
52
41
33
28
24
21
19
17
16
14
69
49
36
28
22
18
15
13
12
10
9
69
46
32
23
17
14
11
9
8
7
6
64
47
37
30
25
21
19
17
15
14
13
64
45
33
25
20
16
14
12
10
9
8
64
43
30
21
16
12
10
8
7
6
5
61
40
27
19
13
10
8
6
5
4
4
Zonal Lumen Summary
Zone
0-30
0-40
0-60
0-90
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
Lumens
555.22
1099.21
3271.60
10717.00
% Lamp
3.2
6.3
18.7
61.2
% Fixture
4.3
8.5
25.3
82.9
Zone
90-120
90-130
90-150
90-180
0-180
Lumens
1669.13
1962.57
2196.06
2217.10
12934.11
% Lamp
9.5
11.2
12.5
12.7
73.9
% Fixture
12.9
15.2
15.2
17.1
100.0
1019
Lighting: Enclosed and Gasketed — Area — HID
Zone
0-10
10-20
20-30
30-40
40-50
50-60
60-70
70-80
80-90
90-100
100-110
110-120
Lighting
0-180
For candlepower values of fixtures with other
PSMH lamps, use the following multipliers:
for 250 W (23,750 lumen) PSMH lamp – 1.36;
for 100 W (8,500 lumen) PSMH lamp – 0.49.
For candlepower values of fixture with guard,
multiply by 0.95.
Mercmaster™ II HID Luminaire Isofootcandle Data
High Pressure Sodium and Pulse Start Metal Halide. Mogul Base
UNILETS® for Use with Threaded Metal Conduit.
Lighting
HPS Lamp
Wattage
Horizontal Distance from Mounting Point (Ft/M)
Mounting Height
(Ft/M)
0/0
5/1.5
10/3.0
15/4.6
Mercmaster II, High Pressure Sodium, No Reflector, No Guard
70 Watt – 5,800 Lumen
100 Watt – 9,500 Lumen
150 Watt – 16,000 Lumen
20/6.1
25/7.6
30/9.1
35/10.7
40/12.2
45/13.7
50/15.2
Lighting: Enclosed and Gasketed — Area — HID
Footcandle Chart (Initial Horiz. FTC)
70
100
150
8/2.4
.60
2.70
1.50
.73
.38
.21
.13
.08
.06
.04
.03
10/3.0
.39
1.70
1.30
.72
.40
.24
.15
.10
.07
.05
.04
12/3.7
.27
1.10
1.10
.68
.41
.26
.17
.11
.08
.06
.04
15/4.6
.17
.66
.81
.60
.39
.26
.18
.13
.09
.07
.05
20/6.1
.10
.37
.43
.40
.33
.25
.18
.13
.10
.08
.06
8/2.4
1.00
4.80
2.70
1.20
.62
.35
.21
.14
.10
.07
.05
10/3.0
.64
2.80
2.20
1.30
.67
.40
.25
.16
.11
.08
.06
12/3.7
.44
1.80
1.80
1.30
.71
.42
.28
.18
.13
.09
.07
15/4.6
.28
1.10
1.30
.97
.70
.45
.30
.21
.15
.11
.08
20/6.1
.16
.59
.69
.70
.55
.42
.32
.23
.17
.13
.10
8/2.4
2.50
8.30
4.60
2.20
1.10
.62
.38
.25
.17
.12
.09
10/3.0
1.60
5.40
4.00
2.20
1.20
.71
.44
.29
.20
.14
.11
12/3.7
1.10
4.20
3.30
2.00
1.20
.76
.49
.33
.23
.17
.12
15/4.6
.72
2.10
2.40
1.80
1.20
.79
.54
.38
.27
.20
.15
20/6.1
.40
1.10
1.30
1.30
1.00
.73
.54
.40
.30
.23
.18
Mercmaster II, High Pressure Sodium, With Reflector, No Guard
70 Watt – 5,800 Lumen
100 Watt – 9,500 Lumen
150 Watt – 16,000 Lumen
Footcandle Chart (Initial Horiz. FTC)
70
100
150
1020
8/2.4
14.80
10.00
3.80
1.50
.55
.15
.05
.03
.02
.01
.01
10/3.0
9.50
7.70
3.70
1.60
.74
.32
.12
.05
.03
.02
.01
12/3.7
6.60
6.60
3.30
1.50
.87
.46
.18
.10
.05
.02
.02
15/4.6
4.20
4.20
2.70
1.70
.94
.56
.33
.18
.10
.06
.03
20/6.1
2.40
2.50
1.90
1.30
.92
.62
.41
.28
.18
.12
.08
8/2.4
21.90
16.80
6.30
2.40
.86
.28
.08
.05
.03
.02
.01
10/3.0
14.00
12.40
6.00
2.70
1.20
.53
.19
.07
.04
.03
.02
12/3.7
9.70
9.40
5.50
2.80
1.40
.73
.36
.20
.13
.04
.03
15/4.6
6.20
6.70
4.40
2.70
1.60
.90
.53
.33
.19
.11
.05
20/6.1
3.50
4.30
3.10
2.20
1.50
1.0
.68
.44
.30
.21
.13
8/2.4
36.90
27.80
10.50
3.80
1.30
.35
.14
.08
.04
.03
.02
10/3.0
23.60
20.80
10.10
4.40
2.00
.78
.29
.11
.07
.04
.03
12/3.7
16.40
15.80
9.20
4.60
2.20
1.20
.54
.30
.16
.06
.04
15/4.6
10.50
11.60
7.50
4.50
2.60
1.50
.86
.42
.26
.16
.08
20/6.1
5.90
7.20
5.20
3.70
2.50
1.70
1.10
.73
.50
.32
.19
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
Mercmaster™ Jr. Luminaires
High Pressure Sodium. Suitable for Use in Wet Locations
UNILETS® for Use with Threaded Metal Conduit. 120 V Integral Ballast. Medium Base Socket for Medium Base Lamps.
With Globe:
70 W: †
35 W, 50 W: †
Class I, Division 2, Groups A, B, C, D
Class I, Division 2, Groups A, B, C, D
Class II, Division 1 and 2, Groups E ‡, F
Class II, Division 1 and 2, Groups E ‡, F, G
Class III
100 W, 150 W: †
Class I, Division 2, Groups A, B, C, D
With Refractor (NEMA V):
150 W: †
35 W, 50 W, 70 W, 100 W: †
Class I, Division 2, Groups A, B, C, D
Class I, Division 2, Groups A, B, C, D
Class II, Division 1 and 2, Groups E ‡, F, G
Class III
Applications
Lighting
• Inexpensive HID integrally ballasted fixture for use in hazardous
locations – inexpensive to buy and inexpensive to operate (uses
one-fifth as much electrical energy as incandescent and threequarters as much as fluorescent).
• Enclosed and gasketed HID lighting fixtures for use in tunnels,
walkways, bridges, storage facilities, processing plants, parking
lots, foundries, manufacturing plants, power plants and other
locations where moisture, dirt, dust or corrosive atmospheres
are encountered.
Features
Lighting: Enclosed and Gasketed — Area — HID
• “Wireless” design. Threading of fixture unit onto mounting hood
makes electrical connection. Only wiring required is attaching
two wires to connection block in mounting hood.
• Safe, easy servicing without disconnecting any wiring.
“Wireless” fixture unit easily threads off mounting hood for
convenient servicing.
• Quick, easy conversion from Appleton V-51® incandescent
installation to Mercmaster Jr. HID. Just remove V-51® fixture
unit and thread Mercmaster Jr. fixture unit onto existing V-51®
mounting hood.
• Choice of mounting hoods. Standard fixtures in pendant, ceiling,
outlet box, wall and stanchion mountings.
• Standard pendant mounting hood for rigid or flexible mounting.
Balanced round design automatically hangs plumb when used
with flexible hanger.
• Unitized construction reduces installation and maintenance
costs.
• Ballast has standard non-PCB biodegradable capacitors.
• Medium base socket is furnished with 392 °F/200 °C leads,
prewired to the ballast. Porcelain socket assures trouble-free
operation in high ambient installations.
• Prismatic glass globe or glass refractor is standard and threads
directly into fixture housing. Eliminates glare and provides
uniform light distribution.
• Fiberglass reinforced polyester reflector for exceptionally severe
corrosive atmospheres. Vented for cooler, dirt-free operation,
increased lumen output.
Illustrated Feature
Conversion from Appleton V-51 incandescent installation to
HID Mercmaster Jr. is easy and fast.
Step No. 1:
After power is shut off, remove present
incandescent V-51 fixture unit from
existing V-51 mounting hood.
Standard Materials
Step No. 2:
Thread Mercmaster Jr. HID fixture unit
onto existing V-51 mounting hood —
and conversion is completed.
• Mounting hoods: copperfree (4/10 of 1% max.) aluminum or
malleable iron
• Ballast bodies: copperfree (4/10 of 1% max.) aluminum
• Guards: copperfree (4/10 of 1% max.) aluminum or steel
• Reflectors: fiberglass reinforced polyester or porcelain
• Globe: 35 W-100 W, threaded prismatic glass and threaded
polycarbonate; 150 W, threaded heat-resistant prismatic glass
• Refractor: heat-resistant prismatic glass
Standard Finishes
• Ballast bodies, aluminum guard and VMA, VXHA-A, OBVW1-A,
OBV1-A, JBW1-A, JB1-A, GSW2 and MS mounting hoods:
epoxy powder coat finish, electrostatically applied for complete,
uniform surface protection
• VA, VXHA, OBVW1, OBV1, GS-2, JBW1, and JB1 malleable iron
mounting hoods: triple coat – (1) zinc electroplate; (2) chromate;
and (3) epoxy powder coat
• Steel guard: zinc electroplate
Options
• Fuses for fixtures, factory installed. Add suffix -F.
Certifications and Compliances
• UL Standard: UL 1598, UL 1598A, UL 844
• UL Listed: E10444
† The MJBW Wall Mount Fixture is suitable for Class I, Division 2, Groups A, B, C and D only.
‡ Per NEC 500.6(1), there is no such classification as Class II, Division 2, Group E.
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
1021
Mercmaster™ Jr. Luminaire Classified Area Suitability and Ballast Data
High Pressure Sodium. Suitable for Use in Wet Locations
UNILETS® for Use with Threaded Metal Conduit. 120 V Integral Ballast. Medium Base Socket for Medium Base Lamps.
Lighting: Enclosed and Gasketed — Area — HID
Lighting
With Globe:
70 W: †
35 W, 50 W: †
Class I, Division 2, Groups A, B, C, D
Class I, Division 2, Groups A, B, C, D
Class II, Division 1 and 2, Groups E ‡, F
Class II, Division 1 and 2, Groups E ‡, F, G
Class III
100 W, 150 W: †
Class I, Division 2, Groups A, B, C, D
With Refractor (NEMA V):
150 W: †
35 W, 50 W, 70 W, 100 W: †
Class I, Division 2, Groups A, B, C, D
Class I, Division 2, Groups A, B, C, D
Class II, Division 1 and 2, Groups E ‡, F, G
Class III
Thermal Suitability
Table at below shows maximum operating temperatures of
Mercmaster Jr. fixtures for Class I, Division 2, in a 104 °F/40
°C ambient. Per NEC 500.8(B)(4), the temperature marking on
fixtures shall not exceed the ignition temperature of the specific
gas or vapor to be encountered. NEC 500.8(B)(4) states that
these markings (Identification Numbers) “marked on equipment
nameplates shall be in accordance with Table NEC 500.8(C).” This
NEC table is duplicated, as it applies to Appleton Mercmaster Jr.
fixtures, in the table below.
As shown, the higher the Temperature Identification Number, the
cooler the fixture operates. Keep this in mind when selecting a
fixture for a specific gas or vapor.
Example:
• Gasoline (56-60 octane)
• Fixture with Globe and Reflector
To determine Mercmaster Jr. thermal suitability for the above
example:
(1) Check the Thermal Suitability on the following page for ignition
temperature of gas or vapor to be encountered. It reveals that
56-60 octane gasoline has an ignition temperature of
536 °F/280 °C.
(2) Look in table below for fixtures under “With Globe and
Reflector” that do not exceed the 536 °F/280 °C ignition
temperature of the gasoline.
(3) Select the best fixture for your purpose. The 35 W, 50 W, 70 W
or 100 W fixture with globe and reflector is acceptable because
none of these fixture lamp surfaces exceed the 536 °F/280 °C
ignition temperature of the gasoline.
Temperature Identification Numbers
Class I, Division 2, Groups A, B, C and D
With Globe or with Globe and Reflector
Lamp
Watts
Class II, Division 1 and 2, Groups E, F and G
With 8” Refractor
With Globe, with Globe and Reflector, or with 8” Refractor
Nameplate
Marking
Temperature
Range (°F/°C)
Nameplate
Marking
Temperature
Range (°F/°C)
Nameplate
Marking
Temperature
Range (°F/°C)
Groups
35
T4
250-275 / 121-135
T4
250-275 / 121-135
T4C
214-248 / 101-120
E, F, G
50
T2D
394-419 / 201-215
T3
358-392 / 181-200
T3C
277-320 / 136-160
E, F, G
70
T2B
448-500 / 231-260
T2C
421-446 / 216-230
T3B
322-329 / 161-165
E, F, G ➊
100
T2A
502-536 / 261-280
T2B
448-500 / 231-260
—
—
E, F, G ➋
150
T2
538-572 / 281-300
T2A
502-536 / 261-280
—
—
—
Ambient Suitability of Mercmaster Jr. Fixtures
Electrical Specifications (Reactor Ballasts)
All fixtures suitable for operation at -40 °F/-40 °C.
35W
50W
70W
100W
150W
104 °F/
40 °C
104 °F/
40 °C
77 °F/
25 °C
77 °F/
25 °C
77 °F/
25 °C
Retrofits Incandescent Fixtures Easily and Quickly
•
•
•
•
•
35 W HPS Comparable to 100/150 W Incandescent Lamp
50 W HPS Comparable to 200 W Incandescent Lamp
70 W HPS Comparable to 300 W Incandescent Lamp
100 W HPS Comparable to 1.5 300 W Incandescent Lamp ➌
150 W HPS Comparable to 2.5 300 W Incandescent Lamp ➌
Lamp
Watts
Line Voltage
60 Hz
Line Current in Amperes
Starting HPF Operating HPF
Input
Watts
35
120
0.41
0.38
43
50
120
0.62
0.56
60
70
120
0.70
0.73
82
100
120
1.10
1.00
115
150
120
1.70
1.50
170
Optional Factory-Installed Fuses – Add Suffix -F
Available as a factory installed item with Mercmaster Jr. fixtures.
➊70W suitable for Groups E and F with globe; suitable for Groups E, F, and G with refractor.
➋ 100W suitable for Groups E, F and G with refractor only.
➌ These are guidelines only. Light distribution and other factors must be taken into consideration.
† The MJBW Wall Mount Fixture is suitable for Class I, Division 2, Groups A, B, C and D only.
‡ Per NEC 500.6(1), there is no such classification as Class II, Division 2, Group E.
1022
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
Mercmaster™ Jr. Luminaires
35 W, 50 W, 70 W, 100 W, 150 W HPS
Complete with Mounting Hood. Medium Base Socket. High Power Factor (Min. P.F. 90%). Integral Ballast for 120 V Line Operation.
With Globe:
70 W: †
35 W, 50 W: †
Class I, Division 2, Groups A, B, C, D
Class I, Division 2, Groups A, B, C, D
Class II, Division 1 and 2, Groups E ‡, F
Class II, Division 1 and 2, Groups E ‡, F, G
Class III
100 W, 150 W: †
Class I, Division 2, Groups A, B, C, D
With Refractor (NEMA V):
150 W: †
35 W, 50 W, 70 W, 100 W: †
Class I, Division 2, Groups A, B, C, D
Class I, Division 2, Groups A, B, C, D
Class II, Division 1 and 2, Groups E ‡, F, G
Class III
S76
S68
S62
S54
S55
—
—
—
—
—
MGSW35-120
MGSW50-120
MGSW70-120
MGSW10-120
MGSW15-120
MGSW35J-120
MGSW50J-120
MGSW70J-120
MGSW10J-120
MGSW15J-120
Wall ➋➌ — Class I, Division 2 only. Aluminum mounting hood and ballast body. Gasket and screws furnished with fixture. Fits JBX Cast Boxes
35
50
70
100
150
S76
S68
S62
S54
S55
25° Stanchion ➍ — Aluminum mounting hood and ballast body. One hub
35
S76
50
S68
70
S62
100
S54
150
S55
—
—
—
—
—
MJBW35-120
MJBW50-120
MJBW70-120
MJBW10-120
MJBW15-120
MJBW35J-120
MJBW50J-120
MJBW70J-120
MJBW10J-120
MJBW15J-120
1-1/4
1-1/2
1-1/4
1-1/2
1-1/2
1-1/2
1-1/4
1-1/2
1-1/4
1-1/2
MS35125-120
MS35150-120
MS50125-120
MS50150-120
MS70125-120
MS70150-120
MS10125-120
MS10150-120
MS15125-120
MS15150-120
MS35125J-120
MS35150J-120
MS50125J-120
MS50150J-120
MS70125J-120
MS70150J-120
MS10125J-120
MS10150J-120
MS15125J-120
MS15150J-120
‡ Per NEC 500.6(1), there is no such classification as Class II, Division 2, Group E.
† The MJBW Wall Mount Fixture is suitable for Class I, Division 2, Groups A, B, C and D only.
All fixtures on this page comply with UL Standard 844 except MJBW Wall Mount Fixture, which is not suitable for Class II, Division 1.
Using cast outlet box with Wall Mount Fixture provides the following clearances: for the globe – JBX box, 1-5/8” from wall; GSU box, 2” from wall; for the
refractor – JBX box, 15/16” from wall; GSW box, 1-5/16” from wall. Reflectors cannot be used with the wall mount fixtures.
Stanchion Mount can be used with standard dome or 30° angle reflector.
To order fixture with guard, add -G before voltage (example: MA3575G-120).
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
1023
Lighting: Enclosed and Gasketed — Area — HID
35
50
70
100
150
Lighting
Catalog Number ➎
With Globe,
With Refractor
ANSI
Hub Size
Less Guard
(NEMA V)
Lamp Watts
Lamp Type
(Inches)
With Globe, Less Guard
With Refractor (NEMA V)
Pendant — Aluminum mounting hood and ballast body. One Hub, Rigid or Flexible Mounting
3/4
MA3575-120
MA3575J-120
35
S76
1
MA3510-120
MA3510J-120
3/4
MA5075-120
MA5075J-120
50
S68
1
MA5010-120
MA5010J-120
3/4
MA7075-120
MA7075J-120
70
S62
1
MA7010-120
MA7010J-120
3/4
MA1075-120
MA1075J-120
100
S54
1
MA1010-120
MA1010J-120
3/4
MA1575-120
MA1575J-120
150
S55
1
MA1510-120
MA1510J-120
Ceiling — Aluminum mounting hood and ballast body. Five Hubs, Four Close-Up Plugs
3/4
MC3575-120
MC3575J-120
35
S76
1
MC3510-120
MC3510J-120
3/4
MC5075-120
MC5075J-120
50
S68
1
MC5010-120
MC5010J-120
3/4
MC7075-120
MC7075J-120
70
S62
1
MC7010-120
MC7010J-120
3/4
MC1075-120
MC1075J-120
100
S54
1
MC1010-120
MC1010J-120
3/4
MC1575-120
MC1575J-120
150
S55
1
MC1510-120
MC1510J-120
Wall ➌ — Malleable iron mounting hood and aluminum ballast body. Gasket and screws furnished with fixture. Fits GSU Cast Boxes
Mercmaster™ Jr. Luminaires
High Pressure Sodium. Suitable for Use in Wet Locations
UNILETS® for Use with Threaded Metal Conduit. 120 V Integral Ballast. Medium Base Socket for Medium Base Lamps.
With Globe:
70 W: †
35 W, 50 W: †
Class I, Division 2, Groups A, B, C, D
Class I, Division 2, Groups A, B, C, D
Class II, Division 1 and 2, Groups E ‡, F
Class II, Division 1 and 2, Groups E ‡, F, G
Class III
100 W, 150 W: †
Class I, Division 2, Groups A, B, C, D
With Globe
With 8” Refractor
With Refractor (NEMA V):
150 W: †
35 W, 50 W, 70 W, 100 W: †
Class I, Division 2, Groups A, B, C, D
Class I, Division 2, Groups A, B, C, D
Class II, Division 1 and 2, Groups E ‡, F, G
Class III
Description
Catalog Number
With Globe ➊ With 8” Refractor
Lamp
Watts
ANSI
Lamp Type
35
S76
MOB35-120
MOB35J-120
50
S68
MOB50-120
MOB50J-120
70
S62
MOB70-120
MOB70J-120
100
S54
MOB10-120
MOB10J-120
150
S55
MOB15-120
MOB15J-120
Lamp
Watts
ANSI
Lamp Type
Catalog Number
S76
35
MUL35-120
S68
50
MUL50-120
S62
70
MUL70-120
S54
100
MUL100-120
S55
150
MUL150-120
S76
35
MBL35-120
S68
50
MBL50-120
S62
70
MBL70-120
S54
100
MBL100-120
S55
150
MBL150-120
Lighting
Outlet Box Fixture
Aluminum ballast housing, complete with
aluminum mounting hood. Epoxy clad.
Lighting: Enclosed and Gasketed — Area — HID
Use with SEH and 3-1/4” or 4” Octagonal
Outlet Box. Fixture furnished with mounting
plate and gasket. Octagonal boxes not
suitable for classified locations.
Fixture Units
Ballast body with globe (VPGL-1 with 35
W, 50 W, 70W and 100W and VPGL-1HR
with 150 W). Use with mounting hoods on
following page or any V-51 series mounting
hood. Polyester or porcelain reflector and
aluminum guard are available. High power
factor (min. P.F. 90%). Ballast provides 120 V
line operation.
Ballast Bodies
Use with mounting hoods on following
page or any V-51 series mounting hood and
with refractor or globe listed. Order other
accessories below as desired. High power
factor (min. P.F. 90%). Ballast provides 120 V
line operation.
‡ Per NEC 500.6(1), there is no such classification as Class II, Division 2, Group E.
† The MJBW Wall Mount Fixture is suitable for Class I, Division 2, Groups A, B, C and D only.
➊ Order JBX or GSU box on following page.
1024
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
Mercmaster™ Jr. Luminaire Mounting Hoods and Outlet Boxes
High Pressure Sodium. Suitable for Use in Wet Locations
UNILETS® for Use with Threaded Metal Conduit. 120 V Integral Ballast. Medium Base Socket for Medium Base Lamps.
Wall
Ceiling
Catalog Number
Hub Size
(Inches)
Aluminum
1/2
—
Malleable Iron
Pendant Mounting Furnished with connection block, gasket and screws
VA
Lighting
VMA
VA50
3/4
VMA75
VA75
1
VMA100
VA100
1/2
VXHA50-A
VXHA50
3/4
VXHA75-A
VXHA75
1
VXHA100-A
VXHA100
Ceiling Mounting Five Hubs. Furnished with connection block, gasket, screws and four close-up plugs
Wall ➎
OBVW1-A
OBVW1
Ceiling
OBV1-A
OBV1
OBV
OBVW
GS Round Base – Fits GSU Cast Boxes ➌ ➍ Furnished with connection block, gasket and screws
GS
GSW
Wall ➎
—
GSW2
Ceiling
—
GS2
JB Round Base – Fits JBX Cast Boxes ➌ ➍ Furnished with connection block, gasket and screws
JB
JBW
Wall ➎
JBW1-A
JBW1
Ceiling
JB1-A
JB1
Stanchion Mounting ➏ 25° Stanchion furnished with connection block and screws.
1-1/4
MS-125
—
1-1/2
MS-150
—
1/2
JBX50L-A
—
3/4
JBX75L-A
—
MS
JBX Cast Conduit Outlet Boxes
JBX
Aluminum. 1-5/16” inside depth. Four tapped openings,
two close-up plugs and mounting lugs. Use with JBW
wall mount fixture and JB round base mounting hoods
GSU Cast Conduit Outlet Box (Form 20)
GSU-20
GSU-100
Malleable iron. 1-3/4” inside depth. Four 3/4” hubs
with four 3/4” to 1/2” reducers, and three 1/2” close-up
plugs. Use with GSW wall mount fixture and GS round
base mounting hoods
1/2 or 3/4
—
GSU-20
1
—
GSU-100
Order SEH box from catalog section A and octagonal box from Section OB. To order fixture with guard, add G before voltage (example: MOB35G-120).
Order JBX below. Using JBX Box with these fixtures and mounting hoods provides 15/16” clearance from wall with refractor and 1-5/8” clearance from wall
with globe.
Order GSU below. Using GSU Box with these fixtures and mounting hoods provides 1-5/16” clearance from wall with refractor and 2” clearance from wall with
globe.
Reflectors cannot be used with wall mount fixtures. See dimensions for globe or refractor clearance from wall for these fixtures.
➏ Stanchion mounting hood can be used with standard dome or 30° angle reflector.
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
1025
Lighting: Enclosed and Gasketed — Area — HID
VXHA
Cast/Outlet Box Mounting Furnished with connection block, mounting plate and gasket. Octagonal outlet box not suitable for classified
locations. Fits SEH and 3-1/4” or 4” Octagonal Box ➋
Mercmaster™ Jr. Luminaire Accessories
High Pressure Sodium. Suitable for Use in Wet Locations
UNILETS® for Use with Threaded Metal Conduit. 120 V Integral Ballast. Medium Base Socket for Medium Base Lamps.
Description
Catalog Number
Lighting
Globes – 35 W-150 W
Lighting: Enclosed and Gasketed — Area — HID
VPGL-1HR
Clear Heat-Resistant Prismatic Glass
VPGL-1HR
Polycarbonate (100W lamp max.) ➋
VPGL-2PL
VPGL-2PL
Description
Light Distribution
IES/NEMA
Distribution Curves
Catalog Number
Refractors – 35 W-150 W
NEMA Type II
LPJR-2CG
NEMA Type V
LPJR-5CG
Closed Prismatic Glass 8” Refractors
Catalog Number
Porcelain
Polyester
Description
Reflectors – 35 W-150 W ➊
Standard
Standard (porcelain, 16” dia.; polyester, 16-1/4” dia.)
LPR-25ST
LPRP-25ST
30° Angle (porcelain, 12” dia.; polyester, 14-3/8” dia.)
LPR-25AN
LPRP-25AN
30° Angle
Description
Catalog Number
Guards – 35 W-150 W
VPGU-1
Copperfree Aluminum Guard
VPGU-1
Steel Guard for 8” Refractors
LPBG-8
35 W-150 W (Medium Base)
JRS-100
Globe Gasket, Silicone Rubber – 35W-150W
VPGL-GK
LPBG-8
Socket
Gasket
➊ V-51 reflectors cannot be used with Mercmaster Jr. Fixtures.
➋ Do not use Polycarbonate Globes in ambients exceeding 77 °F/25 °C. These globes for burning in vertical base-up position only.
1026
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
Mercmaster™ Jr. Luminaire Dimensions
35 W, 50 W, 70 W, 100 W, 150 W
UNILETS® for Use with Threaded Metal Conduit. 120 V Integral Ballast. Medium Base Socket for Medium Base Lamps.
Lighting
Fixture with 8” Refractor
Lighting: Enclosed and Gasketed — Area — HID
MBL Ballast Body
Fixture with Guard and Polyester Reflectors
VXHA Ceiling Mount
VMA Pendant Mount
GSW Wall Mount ➊ and GS Ceiling Mount with GSU Box ➋
➌
Stanchion Mount ❻ ➍
OBV Outlet Box Mount and Mounting Plate
JBW Wall Mount ➊ with JBX Box ➋
➊ Mounting holes 9/32” diameter on 5-1/8” centers. Mounting plate is a separate piece furnished with outlet box mount fixture. The 2.75” dimension is for
mounting on 3-1/4” octagonal boxes and the 3.50” dimension is for 4” octagonal boxes.
➋ Wall mount fixtures provide the following wall clearances: with GSU box – 2” from wall with globe and 1-5/16” from wall with refractor; with JBX box – 1-5/8”
from wall with globe and 15/16” from wall with refractor. Reflectors cannot be used with wall mount fixtures.
➌ Order GSU or JBX box separately.
➍ Standard dome or 30° angle reflectors can be used with stanchion mount.
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
1027
Mercmaster™ LED Luminaires
cETLus Certification. Enclosed and Gasketed
Class I, Division 2, Groups A, B, C, D
Class I, Zone 2
Type 3R, 4X
IP66, IP67
Suitable for Use in Wet Locations
Marine Outside Type (Salt Water)
Lighting: Enclosed and Gasketed — Area — LED/Induction
Lighting
Applications
• Enclosed and gasketed fixtures suitable for use in:
— Marine and wet locations
— A wide range of industrial, chemical processing and other
areas where flammable gases and vapors are present under
conditions defined by the National Electrical Code as Class I,
Division 2
— Areas of low clearance, low ceiling heights or where fixture
weights must be minimized
— Non-hazardous locations where severe weather conditions,
excessive moisture, dirt, dust, corrosive atmosphere or high
ambient temperatures are encountered
• Typical applications include:
— Pulp and paper mills
— Processing plants
— Chemical plants
— Oil refineries
— Foundries
— Manufacturing plants
— Storage areas
— Waste and sewage treatment
— Parking garages
— Other areas where dust, water, dirt and rough usage are a
problem
Features
• Compact light-weight low profile design is suited for low
mounting heights.
• Modular design allows scores of fixture component
combinations to meet installation needs. Uses same mounting
hoods as Mercmaster III.
• Fixture housing and mounting hoods are copperfree cast
aluminum with baked epoxy finish. All exposed hardware is
stainless steel.
• Accommodates a wide range of voltages.
• Ambient: -40 ˚F to 131 ˚F / -40 ˚C to 55 ˚C
• Electrical: 120-277 Vac, 50/60 Hz; 347-480 Vac, 50/60 Hz
• Hinge has high lip for added safety during installation
and servicing. Hinge and bolt construction assures 360º
compression at all points on ballast housing gasket for positive
sealing. Swing away design of captive bolt and nut simplifies
servicing.
• All Mercmaster mounting hoods have provision for easy field
installation of fuses in fixtures (see Fixture Unit — Electrical
Specification).
Certifications and Compliances
• UL Standard: UL 1598, UL 1598A, UL 8750, UL 844
• CSA Standard: C22.2 No. 250, C22.2 No. 137
• cETLus Listed
Related Products
• Photocells for classified use are available, see PCD2 Series.
Standard Materials
• Mounting hoods and bodies: cast copperfree (4/10 of 1% max.)
aluminum
• All hardware and catch assemblies: stainless steel
• Globes: polycarbonate
Standard Finishes
• Mounting hoods, bodies and guards: baked gray epoxy-clad
finish, electrostatically applied for complete uniform protection
1028
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
Mercmaster™ LED Luminaires
cETLus Certification. Enclosed and Gasketed
Class I, Division 2, Groups A, B, C, D
Class I, Zone 2
Type 3R, 4X
IP66, IP67
Suitable for Use in Wet Locations
Marine Outside Type (Salt Water)
Illustrated Features
Driver Assembly
Utilizing non-sparking components
avoiding the ignition of gases or vapors
that may be present (nA).
LED Chamber
Protected by polycarbonate lens, allows
for easy maintenance access.
Lighting
Heatsink
Reliable heat transfer via the cast, epoxy
powder coat aluminum body. Provides
maximum heat dissipation from the LED
assembly to the outside environment.
Modular Plug between LED and driver.
Fuses
Two screws secure fuse kit to mounting
boss in any Mercmaster mounting hood.
Fuse included.
Photocell
Available for all fixtures except cone and
ceiling mount. Installs through knock-out
in mounting hood. Provides continuous
ON-OFF dusk-to-dawn control.
Epoxy Finish
Ballast housing, hoods and guards are
copperfree aluminum with epoxy powder
coat finish.
Electrical Protection
Ground wire provided to bond mounting
hood to ballast housing.
Safety
Rounded heatsink edges prevent possible
injury during installation.
Cooler Operating Cone Hood
Larger sloped surface sheds dusts, dirt
and combustible fibers providing better
heat dissipation.
Mounting Hood and Globe Gaskets
Silicone rubber gaskets seals out
moisture, dirt and dust. Stays flexible,
withstands high temperatures. Closure
design assures uniform gasket
compression.
"Safety" High Hinge
Extra-high hinge provides additional
protection against accidental ballast
housing disengagement during installation
or maintenance.
Stainless Steel Latch Assembly
Captive, stainless steel latch assembly
bolt and nut closes securely, resists attack
of corrosive atmospheres. Swing-away
design simplifies servicing.
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
1029
Lighting: Enclosed and Gasketed — Area — LED/Induction
Terminal Blocks (Zone 2)
A seven-point terminal block is provided
to facilitate wiring. Terminal block
accommodates wire size ranging from #8
to #24 AWG.
Mercmaster™ LED Luminaires
cETLus Certification. Enclosed and Gasketed
Class I, Division 2, Groups A, B, C, D
Class I, Zone 2
Type 3R, 4X
IP66, IP67
Suitable for Use in Wet Locations
Marine Outside Type (Salt Water)
Order using catalog numbering guide below or select catalog number from tables on following pages.
Catalog Numbering Guide
MLED
A
17
Series:
MLED -
Mercmaster
LED
Light Level:
17 - 175 W
Mounting:
A - Pendant
C - Ceiling
D - Pendant Cone
R - 90º Stanchion
S - 25º Stanchion
W - Wall
Lighting
Lighting: Enclosed and Gasketed — Area — LED/Induction
2
P
5
BU
Optical Assembly:
P - Polycarbonate
Globe
Hub Size:
2 - 3/4” NPT
3 - 1” NPT
4 - 1-1/4” NPT
stanchion
5 - 1-1/2” NPT
stanchion
H1
Voltage:
BU - Universal
Voltages
120-277 Vac,
50/60 Hz
BH - 347-480 Vac,
50/60 Hz
Light Distribution:
5 - NEMA 5
Options:
F - Fusing ➊
H1 - Photocontrol 120 V
H2 - Photocontrol 208 V
H3 - Photocontrol 240 V
H4 - Photocontrol 277 V
Technical Data
Lamp
Light Level Equivalent
Type
175 Watt PSMH
Supply Wire
Temperature (°F/°C)
Ambient
Temperature (°F/°C)
Class I, Division 2
149/65
104/40
T4A
167/75
131/55
T4
LED
“T” Numbers Represent the Maximum Lamp Temperature for Class I, Division 2 Locations and
Maximum Surface Temperature Under Dust Blanket for Class II, Division 1 Locations.
“T” #
T1
350
325
T2
T2A
T2B
T2C
T2D
T3
T3A
T3B
T3C
T4
T4A
T5
T6
Temp.
Range (˚ºF)
664842
619662
574617
538572
502536
448500
421446
394419
358392
331356
322329
277320
250275
214248
187212
185
Temp.
Range (°C)
351450
326350
301325
281300
261280
231260
216230
201215
181200
166180
161165
136160
121135
101120
86100
85
➊ Canadian Electrical Code does NOT allow fusing in hazardous locations V.
V CSA Certification Only.
1030
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
Mercmaster™ LED Luminaires
cETLus Certification. Enclosed and Gasketed
Class I, Division 2, Groups A, B, C, D
Class I, Zone 2
Type 3R, 4X
IP66, IP67
Suitable for Use in Wet Locations
Marine Outside Type (Salt Water)
Lamp Type
Light Level
LED
17
Hub Size
(Inches)
Catalog Numbers ➊
3/4
MLEDA172P5
1
MLEDA173P5
3/4
MLEDD172P5
1
MLEDD173P5
3/4
MLEDC172P5
1
MLEDC173P5
Pendant — One Hub, Rigid Mounting
Pendant Cone — One Hub, Rigid Mounting
17
LED
Suffix
BU
BH
Voltage AC
120 - 277
347 - 480
17
Frequency
50/60 Hz
50/60 Hz
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
1031
Lighting: Enclosed and Gasketed — Area — LED/Induction
Ceiling —
Five Hubs, Four Close-up Plugs
Lighting
LED
Mercmaster™ LED Luminaires
cETLus Certification. Enclosed and Gasketed
Class I, Division 2, Groups A, B, C, D
Class I, Zone 2
Type 3R, 4X
IP66, IP67
Suitable for Use in Wet Locations
Marine Outside Type (Salt Water)
Lamp Type
Light Level
LED
17
Hub Size
(Inches)
Catalog Numbers ➊
3/4
MLEDW172P5
1
MLEDW173P5
1-1/4
MLEDS174P5
1-1/2
MLEDS175P5
1-1/4
MLEDR174P5
1-1/2
MLEDR175P5
Wall —
Five Hubs, Four Close-Up Plugs
Lighting: Enclosed and Gasketed — Area — LED/Induction
Lighting
25° Stanchion —
One Hub
LED
17
90° Stanchion —
One Hub
LED
Suffix
BU
BH
1032
Voltage AC
120 - 277
347 - 480
17
Frequency
50/60 Hz
50/60 Hz
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
Mercmaster™ LED Luminaire Mounting Hoods and Ballast Bodies
cETLus Certification. Enclosed and Gasketed
Class I, Division 2, Groups A, B, C, D
Class I, Zone 2
Type 3R, 4X
IP66, IP67
Suitable for Use in Wet Locations
Marine Outside Type (Salt Water)
Mounting Hoods
Description
Hub Size (Inches)
Catalog Number
Pendant
One Hub, Rigid Mounting
3/4
KPA-75
1
KPA-100
3/4
KPCH-75
1
KPCH-100
Pendant Cone
One Hub, Rigid Mounting
Ceiling
Lighting
Five Hubs, Four Close-Up Plugs
3/4
KPC-75
1
KPC-100
3/4
KPWB-75
1
KPWB-100
Wall
Five Hubs, Four Close-Up Plugs
One Hub
1-1/4
KPS-125
1-1/2
KPS-150
1-1/4
KPST-125
1-1/2
KPST-150
90° Stanchion
One Hub
Replacement Globe Gaskets – Silicone Rubber
Description
Catalog Number
KRF-GK
Refractor Gasket
Fixture Unit — Electrical Specification
Catalog Number
Current Draw
Fuse Kit ➊
Fixture Unit
Voltage Range
Voltage
Suffix
120 Vac @ .77 Amps
277 Vac @ .35 Amps
F3
MLED17P5
120-277 Vac, 50/60 Hz
BU
347 Vac @ .32 Amps
480 Vac @ .23 Amps
F3
MLED17P5
347-480 Vac, 50/60 Hz
BH
➊ Canadian Electrical Code does NOT allow fusing in hazardous locations V.
V CSA Certification Only.
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
1033
Lighting: Enclosed and Gasketed — Area — LED/Induction
25° Stanchion
PCD2 Series Factory Sealed Hazardous Location Photocontrol
For Use in Class I, Division 2, Groups A, B, C, D Locations
Maintains Class I, Division 2 rating for Mercmaster III – Low Profile, Mercmaster III, and Mercmaster III – 400 Series Luminaires, Mercmaster LED.
Class I, Division 2, Groups A, B, C, D
NEMA 4X
Applications
Materials
• Encapsulated photocontrol provides automatic dusk-to-dawn
lighting control in Class I, Division 2 locations.
• Typical applications include walkways, security areas and any
other outdoor lighting application.
• For use with Mercmaster III – Low Profile, Mercmaster III, and
Mercmaster III – 400 Series Luminaires.
• For remote mounting in FS Boxes.
• Encapsulated with epoxy sealing compound
• FS: aluminum
Certifications and Compliances
• UL Standard: 1604 – Hazardous (Classified) Locations
• cULus Recognized
Lighting: Enclosed and Gasketed — Area — LED/Induction
Lighting
Features
• Factory sealed design eliminates the need for an explosionproof
enclosure.
• Can be easily installed in the field.
• Solid state design for performance and reliability.
• Available for 120, 208, 240, or 277 volts.
• 50-400 W HID, incandescent or fluorescent, 50/60 Hz.
• 1000 VA Voltage/Ampere
• Minimum time delay: 15 seconds to eliminate nuisance tripping.
• Provided with (3) 18AWG stranded leads 6”/152.4 mm in
length.
• Will fit through standard 1/2” knockout.
Factory-Installed Photocontrol
Dimensions
Add to fixture catalog after voltage; i.e.: KPWBL1075MTH1.
Mercmaster III wall mounting hood
with photocontrol installed shown
Voltage Range
Suffix Designation
120 V, 50/60 Hz
H1
208 V, 50/60 Hz
H2
240 V, 50/60 Hz
H3
277 V, 50/60 Hz
H4
1.13”
28.7
mm
1.13”
28.7 mm
Photocontrol in FS Cover for Use with FS/FD Box
Supplied with two stainless steel screws. For neoprene gasket, order catalog number FS-GKR-1N.
Voltage Range
Catalog Number
120V, 50/60 Hz
FSKA-PC120D2
208-277V, 50/60 Hz
FSKA-PC247D2
1.375”
34.9
mm
1.375”
34.9 mm
2.56”
65.0
mm
2.56”
65.0 mm
1.13”
28.7 mm
Photocontrol for Field Installation
Max. Current
Catalog Number
120 V, 50/60 Hz
Voltage Range
8.3 Amp
PC120D2
208-277 V, 50/60 Hz
3.5 Amp
34.9 mm
PC247D2
2.56”
65.0 mm
1034
1.375”
0.69”
17.5 mm
1.19”
30.2 mm
1.94”
49.2 mm
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
Mercmaster™ LED Luminaire Dimensions
16.93”/
430.0 mm
15.27”/
387.9 mm
cETLus Certification. Enclosed and Gasketed
18.63”/473.2 mm
9.25”/
235.0 mm
77.6 mm
5.59”/
142.0 mm
11.96”/
303.8 mm
25°
15.40”/
391.16 mm
Dia.
Dimensions in Inches/Millimeters
15.40”/391.16 mm Dia.
WALL MOUNT
18.63”/473.2 mm
9.25”/
15.27”/
235.0 mm
387.9 mm
9.79”/248.7 mm
Depends on
Length of
9.25”/
Conduit Used
235.0 mm
18.63”/473.2 mm
10.93”/277.6 mm
17.22”/437.4 mm
5.59”/
142.0 mm
5.59”/
142.0 mm
11.96”/
303.8 mm
4.06”/
8.43”/
103.1
mm mm
214.1
9.40”/
238.8 mm
PENDANT CONE MOUNT
15.27”/
387.9 mm
16.93”/
mm
430.0 18.87”/479.3
mm
10.93”/277.6 mm
4.06”/
103.1 mm
15.40”/391.16 mm Dia.
16.93”/
430.0 mm
ANGLE STANCHION MOUNT
7.56”/
192.0 mm25°
9.40”/
238.8 mm
25°
15.40”/
391.16 mm
15.40”/391.16
mm Dia.
Dia.
15.40”/391.16
mmmm
Dia.Dia.
15.40”/391.16
15.40”/391.16 mm Dia.
CEILING MOUNT
PENDANT MOUNT
WALL MOUNT
15.40”/391.16 mm Dia.
11.96”/
303.8 mm
15.40”/
391.16 mm
Dia.
15.40”/391.16 mm Dia.
STANCHION MOUNT
ANGLE STANCHION MOUNT
PENDANT CONE MOUNT
15.40”/391.16 mm Dia.
Pendant Cone Mount
18.87”/479.3 mm
ANGLE STANCHION MOUNT
WALL MOUNT
PENDANT CONE MOUNT
17.22”/437.4 mm
9.40”/
238.8 mm
PENDANT MOUNT
15.40”/391.16 mm Dia.
15.40”/391.16 mm Dia.
CEILING MOUNT
PENDANT MOUNT
Ceiling Mount
9.40”/
238.8 mm
Wall Mount
WALL MOUNT
15.40”/
391.16 mm
Dia.
15.40”/391.16 mm Dia.
ANGLE STANCHION MOUNT
WALL MOUNT
PENDANT CONE MOUNT
16.93”/
430.0 mm
8.43”/
214.1 mm
18.87”/479.3 mm
15.27”/
387.9 mm
18.63”/473.2 mm
25°
STANCHION MOUNT
15.40”/391.16 mm Dia.
STANCHION MOUNT
15.40”/391.16 mm Dia.
11.96”/
303.8 mm
25°
15.40”/391.16 mm Dia.
5.59”/
142.0 mm
15.40”/391.16 mm Dia.
17.22”/437.4 mm
Depends on
Length of
Conduit Used
9.25”/
235.0 mm
10.93”/277.6 mm
9.25”/
235.0 mm
5.59”/
142.0 mm
9.79”/248.7 mm
15.40”/391.16 mm Dia.
CEILING MOUNT
8.43”/
214.1 mm
7.56”/
192.0 mm
11.96”/
303.8 mm
25°
15.40”/391.16 mm Dia.
15.40”/
391.16 mm
Dia.
15.40”/391.16 mm Dia.
15.40”/391.16 mm Dia.
CEILING MOUNT
STANCHION MOUNT
PENDANT MOUNT
15.40”/391.16 mm Dia.
15.40”/391.16 mm Dia.
STANCHION MOUNT
25° ANGLE
Stanchion
Mount
WALL MOUNT
PENDANT CONE MOUNT
90° Stanchion Mount
18.87”/479.3 mm
17.22”/437.4 mm
Depends on
Length of
Conduit Used
8.43”/
214.1 mm
7.56”/
192.0 mm
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
15.40”/391.16 mm Dia.
15.40”/391.16 mm Dia.
CEILING MOUNT
9.79”/248.7 mm
PENDANT MOUNT
1035
15.40”/391.16 mm Dia.
STANCHION MOUNT
Lighting: Enclosed and Gasketed — Area — LED/Induction
4.06”/
103.1 mm
18.63”/473.2 mm
4.06”/
103.1 mm
7.56”/
192.0 mm
15.40”/391.16 mm Dia.
9.25”/
235.0 mm
CEILING MOUNT
9.79”/248.7 mm
10.93”/277.6 mm
7.56”/
192.0 mm
16.93”/
8.43”/
430.0 mm
214.1 mm
15.27”/
387.9 mm
15.40”/391.16 mm Dia.
18.63”/473.2 mm
15.27”/
387.9 mm
17.22”/437.4 mm
Depends on
Length of
Conduit Used
8.43”/
214.1 mm
16.93”/
430.0 mm
9.79”/248.7 18.87”/479.3
mm
mm
Depends on
Length of
Conduit Used
10.93”/277.6 mm
Lighting
Pendant Mount
ANGLE
15.40”/3
PEND
Mercmaster™ LED Luminaire Weights and Photometric Data
cETLus Certification. Enclosed and Gasketed
Lighting: Enclosed and Gasketed — Area — LED/Induction
Lighting
Mercmaster LED Ballast and Accessory Weights
Description
Weight in Lbs/Kg
Fixture Unit
Pendant
Pendant Cone
22.00/10.0
2.25/1.0
2.50/1.1
Ceiling
3.00/1.4
Wall
4.00/1.8
25° Stanchion
3.25/1.5
90° Stanchion
3.75/1.7
Photometric Data
5 Degree Lumens
0-5
68
5-10
201
10-15
326
CIE Type – Direct
REPORT NUMBER: MLED17P
Lamps: MercMaster LED, Class 1, Div 2, Polycarbonate Optic
Coefficients of Utilization – Zonal Cavity Method
15-20
445
20-25
546
25-30
624
% CeilingRcc
30-35
652
% Walls Rw 70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10
Effective Floor Cavity Reflectance 0.20
80
70
50
30
10
0
0
35-40
646
0 119 119 119 119 116 116 116 116 111 111 111 106 106 106 102 102 102 100
40-45
610
1 111 108 104 102 109 106 103 100 101 99 97 98 96 94 94 93 91 89
45-50
556
2 103 97 91 87 101 95 90 86 91 87 84 88 85 82 85 83 80 78
50-55
473
3 96 87 80 75 93 85 79 74 83 77 73 80 75 72 77 74 70 69
55-60
355
4 88 78 71 65 86 77 70 65 75 69 64 72 67 63 70 66 62 60
60-65
213
65-70
96
70-75
25
75-80
7
Zonal Lumen Summary
Zone
0-30
Lumens
% Fixture
2212
37.8
5 82 71 63 57 80 70 62 57 68 61 56 66 60 56 64 59 55
53
6 76 64 56 51 74 64 56 51 62 55 50 60 54 50 59 53 49
48
7 71 59 51 45 69 58 51 45 57 50 45 55 49 45 54 49 44 43
8 66 54 46 41 65 53 46 41 52 45 41 51 45 40 50 44 40 38
80-85
5
0-40
3509
59.9
9 62 50 42 37 61 49 42 37 48 42
37 47 41 37 46 41 37 35
85-90
3
0-60
5503
94.0
10 58 46 39 34 57 46 39 34 45 38
34 44 38 34 43 37 33 32
5851
99.9
90-95
1
0-90
95-100
1
90-120
3
0.1
100-105
0
90-130
5
0.1
105-110
0
90-150
5
0.1
110-115
1
90-180
5
0.1
0-180
5856
100.0
115-120
1
120-125
1
125-130
1
130-135
0
135-140
0
140-145
0
145-150
0
150-155
0
155-160
0
160-165
0
165-170
0
170-175
0
175-180
0
1036
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
Mercmaster™ III Induction Luminaires
Enclosed and Gasketed. For Hazardous and Adverse Locations
55W, 85W, 165W
Class I, Division 2, Groups A, B, C, D
Class II, Division 1 and 2, Groups E, F, G
NEMA 4X
55W, 85W
Class I, Zone 2
AEx nA nR, IIC
Ex nA nR IIC
165W
Class I, Zone 2
AEx nR, IIC
Ex nR IIC
Applications
Lighting
• Areas where access for relamping is difficult, reliability is
essential and the environment is costly to maintain.
• Cold environment applications.
• Enclosed and gasketed fixtures suitable for use in marine
and wet locations, and in a wide range of industrial, chemical
processing and other areas where flammable gases and vapors
or combustible dusts are present under conditions defined by
NEC Class I, Division 2.
• Fixtures are also well suited for use in non-hazardous areas
where severe weather conditions, excessive moisture, dirt,
dust and corrosive atmospheres are a problem.
• Typical applications include pulp and paper mills, processing
plants, chemical plants, oil refineries, foundries, manufacturing
plants, storage areas and marine applications. Fixtures have
NEMA 4X listing.
Features
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
165 Watt Ceiling Mount Fixture with
Prismatic Glass Globe
Standard Materials
• Mounting hoods, ballast bodies and guards: cast copperfree
(4/10 of 1% max.) aluminum
• Exposed hardware: stainless steel; latch assemblies have
stainless steel bolt and captive nut; reflectors and guards attach
with stainless steel screws threading into stainless steel inserts
• Reflectors: fiberglass reinforced white polyester
• Globes: heat-resistant prismatic glass
Standard Finishes
• Mounting hoods, ballast bodies, guards: epoxy powder
coat finish, electrostatically applied for complete, uniform
surface protection
• Reflectors: white polyester finish
Options
• Fuses can be field-installed on Mercmaster III fixtures. Kits
include fuse block, wire connectors and screws for attaching
to mounting hood. Fixtures with fuses do not comply with
Marine Type Electric Fixtures Outside Type (Salt Water)
requirements for marine listing.
• Photocell optional for all fixtures except cone and ceiling
mounts; provides automatic “on-off” control.
Certifications and Compliances
• UL Standard: UL 1598, UL 844, UL 1598A
• CSA Standard: C22.2 No. 250, C22.2 No. 137
• cCSAus Certified
1037
Lighting: Enclosed and Gasketed — Area — LED/Induction
•
•
Instant start and restrike.
High lumen output and efficacy (up to 73 lumens per Watt).
Fixtures operate safely in a 104 °F/40 °C ambient.
Good lumen maintenance provides less than 30% depreciation
after 60K hours of operation.
Virtually maintenance free.
Ultra long 100,000 hours of life keeps maintenance costs to
a minimum.
Starts in temperatures as low as -40 °F/-40 °C.
Low total harmonic distortion (less than 10%).
No cycling at end of life.
Modular design allows scores of fixture component
combinations to meet installation and lighting needs.
Mounting hoods include cone-shaped pendant, standard
pendant, flexible pendant, ceiling and wall (tapped for 3/4” or 1”
NPT), 25° angle stanchion and straight stanchion (both tapped
for 1-1/4” or 1-1/2” NPT).
Cone hood fixtures for pendant mounting shed dust, dirt and
combustible fibers, and inhibit build-up that “insulates” fixture
and slows heat transfer. Also provide increased surface area for
more effective heat dissipation.
Reflector choice includes standard dome and 30º angle types,
both made of fiberglass reinforced white polyester. Highly
resistant to unusually corrosive applications. Reflectors are
vented for cooler, dirt-free operation and maintained lumen
output. They secure to ballast housing with stainless steel
screws threading into stainless steel inserts.
For high corrosion resistance, fixture housing, mounting hoods
and guards are copperfree (4/10 of 1% max.) cast aluminum
with baked epoxy finish, electrostatically applied for uniformity.
All exposed hardware is stainless steel.
Hinge has high lip for added safety during installation
and servicing. Hinge and bolt construction assures 360º
compression at all points on ballast housing gasket for
positive sealing. Swing-away design of captive bolt and
nut simplifies servicing.
Body gaskets and globe gaskets are high-temperature
silicone rubber.
All Mercmaster III mounting hoods have provision for easy
field installation of fuses in fixtures (see fuse kit listings in this
catalog section).
For electrical protection, a ground wire is provided on each
Mercmaster to bond hood and ballast housing.
Mercmaster™ III Induction Luminaires
Enclosed and Gasketed. For Hazardous and Adverse Locations
55W, 85W, 165W
Class I, Division 2, Groups A, B, C, D
Class II, Division 1 and 2, Groups E, F, G
NEMA 4X
55W, 85W
Class I, Zone 2
AEx nA nR, IIC
Ex nA nR IIC
165W
Class I, Zone 2
AEx nR, IIC
Ex nR IIC
Lighting
Illustrated Features
Aluminum Inner Reflector
Solid aluminum inner reflector improves
photometric efficiency.
Lighting: Enclosed and Gasketed — Area — LED/Induction
Epoxy Finish
Ballast housing, hoods and guards are
copperfree aluminum with epoxy powder
coat finish.
Rugged, Vented Reflectors
Reflectors are thick, tough fiberglass
reinforced white polyester, vented for
cooler operation. Quickly attach with
stainless steel screws provided.
Threaded Stainless Steel Inserts for
Screws
Fixture bodies have stainless steel
threaded inserts to receive stainless steel
screws for reflector and guard. Prevents
“freezing”, allowing guards and reflectors
to be easily removed and replaced at any
time, without damage to the housing.
Prismatic Glass Globes, Refractors
and Enclosed Reflector
Heat-resistant globes, refractors and
enclosed reflectors thread into ballast
housing and seal against a hightemperature silicone rubber gasket.
Fuses Mount to Hood Bosses
Two screws secure fuse kit to mounting
boss in any Mercmaster mounting hood.
Electrical Protection
Ground wire provided to bond mounting
hood to ballast housing.
Stainless Steel
Latch Assembly
Captive, stainless
steel latch assembly
bolt and nut closes
securely, resists
attack of corrosive
atmospheres.
Swing-away design
simplifies servicing.
1038
Mounting Hood and Globe Gaskets
Silicone rubber gaskets seals out
moisture, dirt and dust. Stays flexible,
withstands high temperatures. Closure
design assures uniform gasket
compression.
Cooler Operating Cone Hood
Sloped surface sheds insulating dust,
dirt, and combustible fibers. Provides
cleaner, larger surface area for better heat
dissipation.
Photocell
Available for all fixtures except cone and
ceiling mount. Installs through knock-out
in mounting hood. Provides continuous
ON-OFF dusk-to-dawn control.
“Safety” High
Hinge
Extra-high hinge
provides additional
protection against
accidental
ballast housing
disengagement
during installation
or maintenance.
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
Mercmaster™ III Induction Luminaires
Enclosed and Gasketed. For Hazardous and Adverse Locations
55W, 85W, 165W
Class I, Division 2, Groups A, B, C, D
Class II, Division 1 and 2, Groups E, F, G
NEMA 4X
55W, 85W
Class I, Zone 2
AEx nA nR, IIC
Ex nA nR IIC
165W
Class I, Zone 2
AEx nR, IIC
Ex nR IIC
“T” Numbers for Mercmaster III Induction Fixtures — Class I, Division 2 and Class II, Division 1 and 2
Class I, Division 2, Groups A, B, C, D
NEC/CEC V Temp.
Indent. Number Nameplate Marking
Class II, Division 1 and 2, Groups E, F, G
NEC/CEC V Temp.
Indent. Number Nameplate Marking
Lamp
Type
Supply
Wire
Temp.
(°F/°C)
Ambient
Temp.
(°F/°C)
Input
Voltage
55
Induction
194/90
104/40
100-120
T3A
—
—
T6
—
—
55
Induction
194/90
104/40
200-277
T3B
—
—
T6
—
—
85
Induction
194/90
104/40
100-120
T3A
—
—
T6
—
—
Lamp
Watts
with Globe or
with
with Enclosed
Globe and Reflector Refractor
Reflector
with Globe or
Globe and Reflector
with
with Enclosed
Refractor
Reflector
Induction
194/90
104/40
200-277
T3A
—
—
T6
—
—
Induction
194/90
104/40
100-120
T3
T3
T3
T5
T5
T5
165
Induction
194/90
104/40
200-277
T3
T3
T3
T5
T5
T5
Lighting
85
165
“T” Numbers for Mercmaster III Induction Fixtures —
Class I, Zone 2
Lamp
Type
Supply
Wire
Temp.
(°F/°C)
Ambient
Temp.
(°F/°C)
Input
Voltage
55
Induction
194/90
104/40
55
Induction
194/90
85
Induction
194/90
85
Induction
165
165
Lamp
Watts
Class I, Zone 2
AEx nR IIC / Ex nR IIC
with Globe
with
Globe and
Reflector
with Globe
with Globe
and Reflector
with
Refractor
Reflector
with Lens
100-120
T4
T4
—
—
—
—
104/40
200-277
T4
T4
—
—
—
—
104/40
100-120
T4
T4
—
—
—
—
194/90
104/40
200-277
T4
T4
—
—
—
—
Induction
194/90
104/40
100-120
—
—
T5
T5
—
T5
Induction
194/90
104/40
200-277
—
—
T5
T5
—
T5
“T” Numbers Represent the Maximum Lamp Temperature for Class I, Division 2 Locations and
Maximum Surface Temperature Under Dust Blanket for Class II, Division 1 Locations.
“T”
Number
T1
350
325
T2
T2A
T2B
T2C
T2D
T3
T3A
T3B
T3C
T4
T4A
T5
T6
Temp.
Range
(˚ºF)
664842
619662
574617
538572
502536
448500
421446
394419
358392
331356
322329
277320
250275
214248
187212
185
Temp
Range
(°C)
351-
450
326-
350
301-
325
281-
300
261-
280
231-
260
216-
230
201-
215
181-
200
166-
180
161-
165
136-
160
121-
135
101-
86-100
120
85
V CSA Certification Only.
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
1039
Lighting: Enclosed and Gasketed — Area — LED/Induction
Class I, Zone 2
AEx nA nR IIC / Ex nA nR IIC
Mercmaster™ III Induction Luminaires
Enclosed and Gasketed. For Hazardous and Adverse Locations
55W, 85W, 165W
Class I, Division 2, Groups A, B, C, D
Class II, Division 1 and 2, Groups E, F, G
NEMA 4X
165W
Class I, Zone 2
AEx nR, IIC
Ex nR IIC
55W, 85W ➎➏
Class I, Zone 2
AEx nA nR, IIC
Ex nA nR IIC
Type
Mounting
Lamp
Watts
Hub Size
(Inches)
Catalog Numbers ➊➋➌
with Globe
Pendant
55 ➎➏
One Hub
Rigid Mounting ➍
85 ➎➏
165
Shown with 55 Watt Globe
3/4
MLAQ552G3N
1
MLAQ553G3N
3/4
MLAQ852G4N
1
MLAQ853G4N
3/4
KPAQ1652G4N
1
KPAQ1653G4N
3/4
MLDQ552G3N
1
MLDQ553G3N
3/4
MLDQ852G4N
1
MLDQ853G4N
3/4
KPDQ1652G4N
1
KPDQ1653G4N
3/4
MLCQ552G3N
1
MLCQ553G3N
3/4
MLCQ852G4N
1
MLCQ853G4N
3/4
KPCQ1652G4N
1
KPCQ1653G4N
Lighting
Pendant Cone Hood
55 ➎➏
Lighting: Enclosed and Gasketed — Area — LED/Induction
One Hub
Rigid Mounting
85 ➎➏
165
Shown with 55 Watt Globe
Ceiling
55 ➎➏
Five Hubs
Four Close-Up Plugs
85 ➎➏
Shown with 55 Watt Refractor
165
➊ Add voltage suffix -A1 for 120 Vac: 90-140 Vac; -A6 for 277: 180-305 Vac.
➋ See following pages for accessory ordering information.
➌ For fixtures with guard, substitute G for N before adding suffix.
➍ For flexible pendant mount, change A to F in catalog number.
➎ Add Z2 suffix for factory sealed non-sparking/restricted breathing protection (AEx nA nR).
➏ Add Z suffix for factory sealed non-sparking/restricted breathing protection (Ex nA nR) V.
V CSA Certification Only.
1040
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
Mercmaster™ III Induction Luminaires
Enclosed and Gasketed. For Hazardous and Adverse Locations
55W, 85W, 165W
Class I, Division 2, Groups A, B, C, D
Class II, Division 1 and 2, Groups E, F, G
NEMA 4X
165W
Class I, Zone 2
AEx nR, IIC
Ex nR IIC
55W, 85W ➎➏
Class I, Zone 2
AEx nA nR, IIC
Ex nA nR IIC
Type
Mounting
Lamp
Watts
Hub Size
(Inches)
Catalog Numbers ➊➋➌
with Globe
Wall
55 ➎➏
Five Hubs
Four Close-Up Plugs
85 ➎➏
165
Shown with 85 Watt Globe
3/4
MLWQ552G3N
1
MLWQ553G3N
3/4
MLWQ852G4N
1
MLWQ853G4N
3/4
KPWQ1652G4N
1
KPWQ1653G4N
55 ➎➏
One Hub
85 ➎➏
MLSQ554G3N
1-1/2
MLSQ555G3N
1-1/4
MLSQ854G4N
1-1/2
MLSQ855G4N
1-1/4
KPSQ1654G4N
1-1/2
KPSQ1655G4N
1-1/4
MLRQ554G3N
1-1/2
MLRQ555G3N
1-1/4
MLRQ854G4N
1-1/2
MLRQ855G4N
1-1/4
KPRQ1654G4N
1-1/2
KPRQ1655G4N
Lighting: Enclosed and Gasketed — Area — LED/Induction
165
Shown with 55 Watt Globe
1-1/4
Lighting
25° Stanchion
Straight Stanchion
55 ➎➏
One Hub
85 ➎➏
Shown with 55 Watt Globe
165
➊ Add voltage suffix -A1 for 120 Vac: 90-140 Vac; -A6 for 277: 180-305 Vac.
➋ See following pages for accessory ordering information.
➌ For fixtures with guard, substitute G for N before adding suffix.
➎ Add Z2 suffix for factory sealed non-sparking/restricted breathing protection (AEx nA nR).
➏ Add Z suffix for factory sealed non-sparking/restricted breathing protection (Ex nA nR). V
V CSA Certification Only.
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
1041
Mercmaster™ III Induction Luminaire Mounting Hoods
Enclosed and Gasketed. For Hazardous and Adverse Locations
55W, 85W, 165W
Class I, Division 2, Groups A, B, C, D
Class II, Division 1 and 2, Groups E, F, G
NEMA 4X
55W, 85W
Class I, Zone 2
AEx nA nR, IIC
Ex nA nR IIC
Description
165W
Class I, Zone 2
AEx nR, IIC
Ex nR IIC
Hub Size
(Inches)
Catalog Number
Pendant
One Hub,
Rigid Mounting
3/4
KPA-75
1
KPA-100
One Hub,
Flexible Mounting
3/4
KPAF-75
1
KPAF-100
Cone Hood
Rigid Mounting
3/4
KPCH-75
1
KPCH-100
Five Hubs,
Four Close-Up Plugs
3/4
KPC-75
1
KPC-100
Five Hubs,
Four Close-Up Plugs
3/4
KPWB-75
1
KPWB-100
Lighting: Enclosed and Gasketed — Area — LED/Induction
Lighting
Pendant — Flexible
Pendant Cone
Ceiling
Wall
25° Stanchion
One Hub
1-1/4
KPS-125
1-1/2
KPS-150
1-1/4
KPST-125
1-1/2
KPST-150
90° Stanchion
One Hub
1042
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
Mercmaster™ III Induction Luminaire Fixture Units
Enclosed and Gasketed. For Hazardous and Adverse Locations
55W, 85W, 165W
Class I, Division 2, Groups A, B, C, D
Class II, Division 1 and 2, Groups E, F, G
NEMA 4X
55W, 85W
Class I, Zone 2
AEx nA nR, IIC
Ex nA nR IIC
165W
Class I, Zone 2
AEx nR, IIC
Ex nR IIC
Fixture Units — Less Mounting Hoods
Type
Fixture Unit
Catalog Number
Add Voltage Suffixes
120 V
277 V
Frequency
Lamp Watts
Induction
50/60 Hz
55
MLBRG355Q
-A1
-A6
Induction
50/60 Hz
85
MLBRG485Q
-A1
-A6
Induction
50/60 Hz
165
KPB165QG4
-A1
-A6
Induction
50/60 Hz
165
KPB165QRL
-A1
-A6
Induction
50/60 Hz
165
KPB165QJ2
-A1
-A6
Induction
50/60 Hz
165
KPB165QJ5
-A1
-A6
Globe
Globe
Lighting
Globe
Lighting: Enclosed and Gasketed — Area — LED/Induction
Enclosed Reflector/Lens
Type 2 Refractor
Type 5 Refractor
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
1043
Mercmaster™ III Induction Luminaire Accessories and Replacement Parts
Enclosed and Gasketed. For Hazardous and Adverse Locations
55W, 85W, 165W
Class I, Division 2, Groups A, B, C, D
Class II, Division 1 and 2, Groups E, F, G
NEMA 4X
55W, 85W
Class I, Zone 2
AEx nA nR, IIC
Ex nA nR IIC
Item
165W
Class I, Zone 2
AEx nR, IIC
Ex nR IIC
Description
Watts
Catalog Number
Standard Dome
55 W, 85 W, 165 W
CMR-4ST ➊
Deep Dome (Dark Skies Compliant)
55 W, 85 W, 165 W
CMR-4DD ➊
30º Angle
55 W, 85 W, 165 W
CMR-4AN ➊
White Polyester Reflectors
Lighting
Prismatic Glass Globes – Heat-Resistant
Clear
55 W
VPGL-3HR
Clear
85 W, 165 W
VPGL-4HR
Closed Glass Refractor NEMA Type II
Heat- and impact-resistant glass lens.
165 W
KPRF4002
Closed Glass Refractor NEMA Type V
165 W
KPRF4005
Enclosed Reflector/Lens
165 W
KPR-4HB
55 W
KRG2
Lighting: Enclosed and Gasketed — Area — LED/Induction
Refractor/Reflector Assemblies
Guards
85 W, 165 W
KPGU400
Mercmaster III Fixture Unit, Component and Accessory Weights ➋
Fixture Unit and Mounting Hoods
55W and 85W Fixture
165W Fixture
Pendant
Pendant Cone
Ceiling
Wall
25º Stanchion
90º Stanchion
Wt. lbs/kg
28.00/12.7
33.00/15.0
2.25/1.0
2.50/1.1
3.00/1.4
4.00/1.8
3.25/1.5
3.33/1.5
Reflectors
Standard Dome
30º Angle
Deep Dome
Wt. lbs/kg
2.50/1.1
2.50/1.1
3.50/1.6
Refractors, Globes & Guard
Glass Globe
Globe Guard
Wt. lbs/kg
3.75/1.7
1.00/0.5
➊ Standard and deep dome reflectors may interfere with bottom conduit entry if used with KPST and KPWB mounting hoods.
➋ Weights are approximate.
1044
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
Mercmaster™ III Induction Luminaire Technical Data
Enclosed and Gasketed. For Hazardous and Adverse Locations
55W, 85W, 165W
Class I, Division 2, Groups A, B, C, D
Class II, Division 1 and 2, Groups E, F, G
NEMA 4X
55W, 85W
Class I, Zone 2
AEx nA nR, IIC
Ex nA nR IIC
165W
Class I, Zone 2
AEx nR, IIC
Ex nR IIC
Fuse Kit includes fuse, fuse holder and necessary hardware for field installation. Mounts easily to hood with one screw. ➊
Lamp Watts
55, 85, 165
Volts
120/277
208-240
Fuse Qty. Req.
1
2
Fuse Catalog Number
F2
F2
Electromagnetic Compatibility
A.) Complies with European norms EN55015, EN6100-3-2 and EN61547
B.) RFI
a.) Meets standard EN55022 and is valid for frequencies up to 1000 MHz.
Electrical Characteristics
MHz
MHz
MHz
kV
mA
85 W
100-120 V
85
82
88
120
90
140
120
90
180
60
47
63
730
16
170
>0.92
2.65
2.3
3
1.5
<0.5
200Vac
85 W
200-277 V
85
82
88
230
180
305
230
180
350
50
47
63
400
12
170
>0.92
2.65
2.3
3
1.5
<0.5
400Vac
165 W
100-120 V
165
160
190
120
90
140
120
90
180
60
47
63
1420
28
150
>0.92
2.65
2.3
3.0
1.5
<0.5
200Vac
165 W
200-277 V
165
160
190
230
180
305
230
180
350
50
47
63
740
24
140
>0.92
2.65
2.3
3.0
1.5
<0.5
400Vac
Lamp Characteristics
Values at 100 Hrs.
Luminous flux nom.
Luminous flux min.
Luminous flux max.
System efficacy nom.
lm
lm
lm
lm/W
QL 55 W
3,500
3,200
3,800
63.5
QL 85 W
6,000
5,500
6,500
70
QL 165 W
12,000
11,000
12,500
72.5
Lamp Operation
A.) Ignition and Lifetime Performance
a.) Ignition time <0.5 seconds
Hot Restrike time <0.5 seconds
b.) Induction lighting offers a direct, flicker-free ignition after switch-on, in both cold and hot conditions
B.) Lumen Maintenance
a.)The lumens of an induction lamp are expected to have depreciated after 60,000 hours to no less than 75% of the initial lumens
➊ Canadian Electrical Code does NOT allow fusing in hazardous locations V.
➋ At design voltage.
V CSA Certification Only.
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
1045
Lighting: Enclosed and Gasketed — Area — LED/Induction
W
W
W
V
V
V
V
V
V
Hz
Hz
Hz
mA
A
usec
55 W
200-277 V
55
53.1
56.9
230
180
305
230
180
350
50
47
63
260
12
170
>0.92
2.65
2.3
3
1.5
<0.5
400Vac
Lighting
System power ➋ nom.
System power ➋ min.
System power ➋ max.
AC supply voltage nom.
AC supply voltage min.
AC supply voltage max.
DC supply voltage nom.
DC supply voltage min.
DC supply voltage max.
Supply frequency nom.
Supply frequency min.
Supply frequency max.
Supply current nom.
Inrush current max.
Duration inrush current max.
Power factor nom.
HF output frequency nom.
HF output frequency min.
HF output frequency max.
HF output voltage max.
Leakage current
Overvoltage
55 W
100-120 V
55
53.1
56.9
120
90
140
120
90
180
60
47
63
460
16
170
>0.92
2.65
2.3
3
1.5
<0.5
200Vac
Mercmaster™ III Induction Luminaire Dimensions
Enclosed and Gasketed. For Hazardous and Adverse Locations
13.44"/
341.4 mm
11.82"/
300.2 mm
10.38"/
263.7 mm
10.25"/
260.4 mm
10.77"/
273.6 mm
Lighting
11.44"/
290.6 mm
12.25"/
311.2 mm Dia.
14.25"/
362.0 mm Dia.
1046
10.52”/
267.2 mm
11.32"/
287.5 mm
15.72"/
399.3 mm
15.17"/
385.3 mm
14.81"/
376.2 mm
10.52"/
267.2 mm
85 Watt
12.37"/
314.2 mm
14.81"/
376.2 mm
4.24”/
107.7 mm
165 Watt Ceiling Mount
with Refractor, Enclosed Reflector and Guards
4.24"/
107.7 mm
Lighting: Enclosed and Gasketed — Area — LED/Induction
165 Watt Pendant with Globe,
Guard and Reflectors
16.38"/
416.1 mm Dia.
16.63"/
422.4 mm Dia.
55 Watt
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
Mercmaster™ III Induction Luminaire Dimensions
Enclosed and Gasketed. For Hazardous and Adverse Locations
Pendant (Rigid or Flex)
Pendant Cone
12.06"/
306.3 mm
Ceiling
13.62"/
346.9 mm
12.06"/
306.3 mm
12.06"/
306.3 mm
1.17"/
29.7 mm
5.59"/
142.0 mm
1.75"/
44.5 mm
25° Stanchion
5”/
9.2 0 mm
.
5
23
25°
0”/
2.0 mm
8
.
50
”/
.03 m
12 .6 m
5
30
9.79”/
248.7 mm
SET SCREW
Wall Mount
17.00"/
431.8 mm
10.93”/
277.6 mm
12.03”/
305.6 mm
12.03”/
305.6 mm
Lighting: Enclosed and Gasketed — Area — LED/Induction
t
Se w
re
Sc
17.23”/
437.6 mm
Lighting
/
27”
15. .9 mm
7
38
90° Stanchion
3.36"/
85.3 mm
1.57"/
39.9 mm
9”/
7.5 8 mm
.
2
19
4.06"/
103.1 mm
2.03"/
51.6 mm
Standard Polyester Reflector
30º Angle Polyester Reflector
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
Deep Dome
1047
PCD2 Series Factory Sealed Hazardous Location Photocontrol
For Use in Class I, Division 2, Groups A, B, C, D Locations
Maintains Class I, Division 2 rating for Mercmaster III – Low Profile, Mercmaster III, and Mercmaster III – 400 Series Luminaires, Mercmaster LED.
Class I, Division 2, Groups A, B, C, D
NEMA 4X
Applications
Materials
• Encapsulated photocontrol provides automatic dusk-to-dawn
lighting control in Class I, Division 2 locations.
• Typical applications include walkways, security areas and any
other outdoor lighting application.
• For use with Mercmaster III – Low Profile, Mercmaster III, and
Mercmaster III – 400 Series Luminaires.
• For remote mounting in FS Boxes.
• Encapsulated with epoxy sealing compound
• FS: aluminum
Certifications and Compliances
• UL Standard: 1604 – Hazardous (Classified) Locations
• cULus Recognized
Lighting: Enclosed and Gasketed — Area — LED/Induction
Lighting
Features
• Factory sealed design eliminates the need for an explosionproof
enclosure.
• Can be easily installed in the field.
• Solid state design for performance and reliability.
• Available for 120, 208, 240, or 277 volts.
• 50-400 W HID, incandescent or fluorescent, 50/60 Hz.
• 1000 VA Voltage/Ampere
• Minimum time delay: 15 seconds to eliminate nuisiance tripping.
• Provided with (3) 18AWG stranded leads 6”/152.4mm in length.
• Will fit through standard 1/2” knockout.
Factory-Installed Photocontrol
Dimensions
Add to fixture catalog after voltage; i.e.: KPWBL1075MTH1.
Mercmaster III wall mounting hood
with photocontrol installed shown
Voltage Range
Suffix Designation
120 V, 50/60 Hz
H1
208 V, 50/60 Hz
H2
240 V, 50/60 Hz
H3
277 V, 50/60 Hz
H4
1.13”
28.7
mm
1.13”
28.7 mm
Photocontrol in FS Cover for Use with FS/FD Box
Supplied with two stainless steel screws. For neoprene gasket, order catalog number FS-GKR-1N.
Voltage Range
Catalog Number
120V, 50/60 Hz
FSKA-PC120D2
208-277V, 50/60 Hz
FSKA-PC247D2
1.375”
34.9
mm
1.375”
34.9 mm
2.56”
65.0
mm
2.56”
65.0 mm
1.13”
28.7 mm
Photocontrol for Field Installation
Max. Current
Catalog Number
120 V, 50/60 Hz
Voltage Range
8.3 Amp
PC120D2
208-277 V, 50/60 Hz
3.5 Amp
34.9 mm
PC247D2
2.56”
65.0 mm
1048
1.375”
0.69”
17.5 mm
1.19”
30.2 mm
1.94”
49.2 mm
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
Mercmaster™ III Induction Luminaire 55 W Photometric Data
Enclosed and Gasketed. For Hazardous and Adverse Locations
Total Luminaire Efficiency = 78%
CIE Type – General Diffuse
REPORT NUMBER: MLBR55QL
Lamps: 55 W QL lamp with Globe only
Coefficients of Utilization - Zonal Cavity Method
Effective Floor Cavity Reflectance 0.20
110-120
254.71
120-130
130-140
140-150
150-160
160-170
170-180
184.93
87.45
16.45
16.70
0.05
0.00
Total Luminaire Efficiency = 68.6%
CIE Type – Direct
Spacing Criteria: 1.40
70
50
30
10
0
% Walls Rw
70 50 30 10
70 50 30 10
50 30 10
50 30 10
50 30 10
0
85
73
65
59
53
48
44
41
38
35
33
79
68
60
54
49
44
41
38
35
32
30
69
54
45
38
33
29
26
24
21
19
18
59
45
37
32
28
24
22
20
18
16
15
50
37
31
26
22
20
18
16
15
13
12
0
1
2
3
4
5
6
7
8
9
10
85
68
57
49
43
38
33
30
27
24
22
85
64
51
42
35
30
26
23
20
18
16
85
59
45
36
29
24
21
18
15
14
12
79
63
53
45
39
35
31
28
25
23
21
79
59
47
39
33
28
24
21
19
17
15
79
55
42
33
27
23
19
17
14
13
11
69
51
40
33
28
24
21
18
16
14
13
69
48
36
29
23
20
17
14
12
11
10
59
43
34
28
23
20
17
15
14
12
11
59
40
31
24
20
16
14
12
10
9
8
50
35
28
23
19
16
14
12
11
10
9
50
34
25
20
16
13
11
10
9
8
7
46
30
22
17
13
11
9
8
7
6
5
Zonal Lumen Summary
Zone
0-30
0-40
0-60
0-90
Lumens
173.63
318.76
743.26
1597.39
% Lamp
5.0
9.1
21.2
45.6
% Fixture
6.4
11.7
27.2
58.5
Zone
90-120
90-130
90-150
90-180
0-180
Lumens
842.61
1027.54
1131.69
1132.40
2729.80
% Lamp
24.1
29.4
32.3
32.4
78.0
% Fixture
30.9
37.6
37.6
41.5
100.0
REPORT NUMBER: MLBR55QLST
Lamps: 55 W QL lamp with Standard Dome Reflector
Coefficients of Utilization - Zonal Cavity Method
Effective Floor Cavity Reflectance 0.20
Zone
0-10
10-20
20-30
30-40
40-50
50-60
60-70
70-80
80-90
90-100
100-110
Lumens
53.72
151.63
237.12
314.91
369.39
394.66
389.48
306.69
141.30
20.15
4.14
110-120
4.10
120-130
130-140
140-150
150-160
160-170
170-180
5.12
4.61
1.93
0.37
0.11
0.04
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
% Ceiling Rcc
80
70
50
30
10
0
% Walls Rw
70 50 30 10
70 50 30 10
50 30 10
50 30 10
50 30 10
0
81
72
67
58
52
48
44
41
38
35
33
79
70
62
56
51
46
43
39
37
34
32
76
63
53
46
40
35
32
29
26
24
22
72
60
51
44
38
34
30
28
25
23
21
69
57
48
42
37
32
29
23
24
22
21
0
1
2
3
4
5
6
7
8
9
10
81
68
57
49
43
38
34
31
28
25
23
81
64
52
43
36
31
27
24
21
19
17
81
61
47
38
31
26
22
19
17
15
14
79
66
56
48
42
37
33
30
27
25
23
79
63
51
42
36
31
27
24
21
19
17
79
60
46
37
31
26
22
19
17
15
14
76
60
49
41
34
30
26
23
21
19
17
76
57
45
36
30
25
22
19
17
15
13
72
58
47
39
33
29
25
22
20
18
17
72
55
44
35
29
25
21
19
17
15
13
69
55
45
38
32
28
25
22
20
18
16
69
54
43
35
29
25
21
18
16
15
13
67
52
14
33
27
23
20
17
15
13
12
Zonal Lumen Summary
Zone
0-30
0-40
0-60
0-90
Lumens
442.48
757.38
1521.42
2358.89
% Lamp
12.6
21.6
43.5
67.4
% Fixture
18.4
31.6
63.4
98.3
Zone
90-120
90-130
90-150
90-180
0-180
Lumens
28.39
33.51
40.05
40.58
2399.47
% Lamp
0.8
1.0
1.1
1.2
68.6
% Fixture
1.2
1.4
1.4
1.7
100.0
1049
Lighting: Enclosed and Gasketed — Area — LED/Induction
Lumens
20.62
57.15
95.87
145.23
191.57
232.82
266.04
288.86
299.24
299.72
288.18
80
Lighting
Zone
0-10
10-20
20-30
30-40
40-50
50-60
60-70
70-80
80-90
90-100
100-110
% Ceiling Rcc
Mercmaster™ III Induction Luminaire 55 W Photometric Data
Enclosed and Gasketed. For Hazardous and Adverse Locations
Total Luminaire Efficiency = 61.1%
CIE Type – Direct
Spacing Criteria: 1.80
REPORT NUMBER: MLBR55QLAN
Lamps: 55 W QL lamp with 30° Angle Dome Reflector
Coefficients of Utilization - Zonal Cavity Method
Lighting: Enclosed and Gasketed — Area — LED/Induction
Lighting
Effective Floor Cavity Reflectance 0.20
Zone
0-10
10-20
20-30
30-40
40-50
50-60
60-70
70-80
80-90
90-100
100-110
Lumens
42.29
134.14
213.06
282.99
314.71
306.62
275.85
232.10
171.94
100.63
40.56
110-120
9.45
120-130
130-140
140-150
150-160
160-170
170-180
3.75
2.43
0.97
0.34
0.25
0.06
Total Luminaire Efficiency = 59.2%
CIE Type – Direct
Spacing Criteria: 1.58
% Ceiling Rcc
80
70
50
30
10
0
% Walls Rw
70 50 30 10
70 50 30 10
50 30 10
50 30 10
50 30 10
0
72
63
57
51
47
43
39
36
34
31
29
69
61
55
49
45
41
38
35
32
30
28
65
54
46
40
35
31
28
25
23
21
20
62
51
43
38
33
29
27
24
22
20
19
58
48
41
35
31
28
25
23
21
19
18
0
1
2
3
4
5
6
7
8
9
10
72
59
51
44
38
34
30
27
25
23
21
72
56
46
38
32
28
25
22
19
18
16
72
53
42
34
28
24
20
18
16
14
13
69
58
49
43
37
33
30
27
24
22
20
69
55
45
37
32
27
24
21
19
17
16
69
52
41
33
27
23
20
18
15
14
12
65
52
42
35
30
26
23
21
18
17
15
65
49
39
32
27
23
20
17
15
13
12
62
49
40
34
29
25
22
20
18
16
15
62
47
37
31
26
22
19
17
15
13
12
58
46
38
32
28
24
21
19
17
16
14
58
45
36
30
25
21
18
16
14
13
12
57
42
34
28
23
20
17
15
13
12
10
Zonal Lumen Summary
Zone
0-30
0-40
0-60
0-90
Lumens
394.49
677.48
1298.80
1978.69
% Lamp
11.3
19.4
37.1
56.5
% Fixture
18.5
31.7
60.8
92.6
Zone
90-120
90-130
90-150
90-180
0-180
Lumens
150.64
154.39
157.79
158.45
2137.14
% Lamp
4.3
4.4
4.5
4.5
61.1
% Fixture
7.0
7.2
7.2
7.4
100.0
REPORT NUMBER: MLBR55QLHB
Lamps: 55 W QL lamp with High Bay Reflector
Coefficients of Utilization - Zonal Cavity Method
Effective Floor Cavity Reflectance 0.20
Zone
0-10
10-20
20-30
30-40
40-50
50-60
60-70
70-80
80-90
90-100
100-110
110-120
Lumens
64.78
196.79
326.97
437.52
470.90
345.47
167.60
52.79
7.73
0.00
0.00
0.14
120-130
130-140
140-150
150-160
160-170
170-180
0.26
0.16
0.24
0.00
0.04
0.02
1050
% Ceiling Rcc
80
70
50
30
10
0
% Walls Rw
70 50 30 10
70 50 30 10
50 30 10
50 30 10
50 30 10
0
70
65
60
55
50
46
43
40
37
34
32
69
64
58
54
49
45
42
39
36
34
31
66
59
52
47
42
37
34
31
28
26
24
63
57
51
45
40
36
33
30
27
25
23
60
55
49
44
39
35
32
29
26
24
22
0
1
2
3
4
5
6
7
8
9
10
70
63
56
49
44
39
35
32
29
27
24
70
61
52
45
39
34
30
27
24
22
20
70
59
49
41
35
30
27
23
21
19
17
69
62
54
48
43
39
35
31
29
26
24
69
60
51
44
39
34
30
27
24
22
20
69
58
48
41
35
30
26
23
21
19
17
66
57
40
43
38
33
29
26
24
21
19
66
56
47
40
35
30
26
23
21
18
17
63
55
48
42
37
32
29
26
23
21
19
63
54
46
40
34
30
26
23
20
18
17
60
54
47
41
36
32
28
25
23
21
19
60
53
45
39
34
29
26
23
20
18
17
59
51
44
38
32
28
25
22
19
17
15
Zonal Lumen Summary
Zone
0-30
0-40
0-60
0-90
Lumens
588.53
1026.05
1842.43
2070.54
% Lamp
16.8
29.3
52.6
59.2
% Fixture
28.4
49.5
88.9
100.0
Zone
90-120
90-130
90-150
90-180
0-180
Lumens
0.14
0.41
0.81
0.87
2071.41
% Lamp
0.0
0.0
0.0
0.0
59.2
% Fixture
0.0
0.0
0.0
0.0
100.0
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
Mercmaster™ III Induction Luminaire 85 W Photometric Data
Enclosed and Gasketed. For Hazardous and Adverse Locations
Total Luminaire Efficiency = 78.4%
CIE Type – General Diffuse
REPORT NUMBER: MLBR85QL
Lamps: 85 W QL lamp with Globe only
Coefficients of Utilization - Zonal Cavity Method
Effective Floor Cavity Reflectance 0.20
% Ceiling Rcc
% Walls
110-120
439.16
120-130
318.85
130-140
140-150
150-160
160-170
170-180
150.78
28.79
1.15
0.08
0.00
Total Luminaire Efficiency = 69%
CIE Type – Direct
Plane
Spacing
Criteria
0-180
1.40
90-270
1.40
Diagonal
1.58
110-120
7.07
8.83
7.95
3.33
0.64
0.19
0.07
10
0
50 30 10
50 30 10
50 30 10
0
0
1
2
3
4
5
6
7
8
9
10
86
74
66
59
53
49
45
41
38
35
33
80
68
60
54
49
45
41
38
35
33
30
69
54
45
39
34
30
26
24
21
20
18
59
46
38
32
28
25
22
20
18
16
15
50
38
31
26
23
20
18
16
15
13
12
86
69
58
49
43
38
34
30
27
25
23
86
64
51
42
35
30
26
23
20
18
16
86
60
46
36
29
25
21
18
16
14
12
80
64
53
46
40
35
31
28
25
23
21
80
59
47
39
33
28
24
21
19
17
15
80
56
42
34
27
23
19
17
14
13
11
69
51
41
33
28
24
21
18
16
15
13
69
48
36
29
24
20
17
14
12
11
10
59
43
34
28
23
20
17
15
14
12
11
59
41
31
24
20
17
14
12
11
9
8
50
36
28
23
19
16
14
13
11
10
9
50
34
25
20
16
13
11
10
9
8
7
46
30
22
17
13
11
9
8
7
6
5
Lumens
299.37
549.76
1281.48
2754.13
% Lamp
5.0
9.2
21.4
45.9
% Fixture
6.4
11.7
27.2
58.5
Zone
90-120
90-130
90-150
90-180
0-180
Lumens
1452.77
1771.62
1951.19
1952.42
4706.55
% Lamp
24.2
29.5
32.5
32.5
78.4
% Fixture
30.9
37.6
37.6
41.5
100.0
REPORT NUMBER: MLBR85QLST
Lamps: 85 W QL lamp with Standard Dome Reflector
Coefficients of Utilization - Zonal Cavity Method
Effective Floor Cavity Reflectance 0.20
% Ceiling Rcc
Lumens
92.63
261.43
408.83
542.94
636.87
680.44
671.51
528.78
243.62
34.74
7.14
120-130
130-140
140-150
150-160
160-170
170-180
30
70 50 30 10
Zonal Lumen Summary
Zone
0-30
0-40
0-60
0-90
% Walls
Zone
0-10
10-20
20-30
30-40
40-50
50-60
60-70
70-80
80-90
90-100
100-110
50
70 50 30 10
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
80
70
50
30
10
0
Rw
70 50 30 10
70 50 30 10
50 30 10
50 30 10
50 30 10
0
0
1
2
3
4
5
6
7
8
9
10
82
73
65
58
53
48
44
41
38
35
33
80
70
63
56
51
47
43
40
37
34
32
76
63
54
46
40
36
32
29
26
24
22
72
60
51
44
38
34
31
28
25
23
21
69
58
49
42
37
33
29
27
24
22
21
82
68
58
50
43
38
34
31
28
25
23
82
65
52
43
36
31
27
24
21
19
18
82
61
47
38
31
26
22
19
17
15
14
80
67
56
48
42
37
33
30
27
25
23
80
63
51
42
36
31
27
24
21
19
17
80
60
47
37
31
26
22
19
17
15
14
76
60
49
41
35
30
26
23
21
19
17
76
58
45
37
30
25
22
19
17
15
13
72
58
47
39
34
29
25
23
20
18
17
72
56
44
36
30
25
22
19
17
15
13
69
56
46
38
33
28
25
22
20
18
16
69
54
43
35
29
25
21
19
16
15
13
68
52
41
33
27
23
20
17
15
13
12
Zonal Lumen Summary
Zone
0-30
0-40
0-60
0-90
Lumens
762.89
1305.83
2623.14
4067.06
% Lamp
12.7
21.8
43.7
67.8
% Fixture
18.4
31.6
63.4
98.3
Zone
90-120
90-130
90-150
90-180
0-180
Lumens
48.95
57.78
69.06
69.96
4137.02
% Lamp
0.8
1.0
1.2
1.2
69.0
% Fixture
1.2
1.4
1.4
1.7
100.0
1051
Lighting: Enclosed and Gasketed — Area — LED/Induction
Lumens
35.55
98.53
165.29
250.39
330.30
401.42
458.68
498.03
515.94
516.75
496.86
70
Rw
Lighting
Zone
0-10
10-20
20-30
30-40
40-50
50-60
60-70
70-80
80-90
90-100
100-110
80
Mercmaster™ III Induction Luminaire 85 W Photometric Data
Enclosed and Gasketed. For Hazardous and Adverse Locations
Total Luminaire Efficiency = 61.4%
CIE Type – Direct
Plane
Spacing
Criteria
0-180
1.80
90-270
1.44
Diagonal
1.54
REPORT NUMBER: MLBR85QLAN
Lamps: 85 W QL lamp with 30° Angle Dome Reflector
Coefficients of Utilization - Zonal Cavity Method
Effective Floor Cavity Reflectance 0.20
% Ceiling Rcc
Lighting: Enclosed and Gasketed — Area — LED/Induction
Lighting
% Walls
Zone
0-10
10-20
20-30
30-40
40-50
50-60
60-70
70-80
80-90
90-100
100-110
Lumens
81.53
231.27
367.34
487.91
542.61
528.65
475.60
400.17
296.45
173.50
69.93
110-120
16.29
120-130
6.47
130-140
140-150
150-160
160-170
170-180
4.19
1.67
0.59
0.44
0.10
Total Luminaire Efficiency = 59.5%
CIE Type – Direct
Plane
Spacing
Criteria
0-180
1.58
90-270
1.58
Diagonal
1.58
110-120
0.25
0.46
0.28
0.41
0.00
0.07
0.04
1052
50
30
10
0
70 50 30 10
70 50 30 10
50 30 10
50 30 10
50 30 10
0
0
1
2
3
4
5
6
7
8
9
10
72
64
57
52
47
43
39
36
34
32
30
70
61
55
49
45
41
38
35
33
30
29
66
54
46
40
35
31
28
25
23
21
20
62
51
44
38
33
30
27
24
22
20
19
58
48
41
36
31
28
25
23
21
19
18
72
60
51
44
39
34
31
28
25
23
21
72
56
46
38
33
28
25
22
20
18
16
72
53
42
34
28
24
20
18
16
14
13
70
58
49
43
38
33
30
27
24
22
21
70
55
45
37
32
28
24
21
19
17
16
70
52
41
33
28
23
20
18
16
14
12
66
52
43
36
31
26
23
21
19
17
15
66
50
39
32
27
23
20
17
15
14
12
62
49
40
34
29
25
22
20
18
16
15
62
47
38
31
26
22
19
17
15
13
12
58
46
38
32
28
24
21
19
17
16
14
58
45
36
30
25
21
19
16
14
13
12
57
43
34
28
23
20
17
15
13
12
11
Lumens
680.15
1168.06
2239.32
3411.54
% Lamp
11.3
19.5
37.3
56.9
% Fixture
18.5
31.7
60.8
92.6
Zone
90-120
90-130
90-150
90-180
0-180
Lumens
259.73
266.19
272.06
273.19
2684.73
% Lamp
4.3
4.4
4.5
4.6
61.4
% Fixture
7.0
7.2
7.2
7.4
100.0
REPORT NUMBER: MLBR85QLHB
Lamps: 85 W QL lamp with High Bay Reflector
Coefficients of Utilization - Zonal Cavity Method
Effective Floor Cavity Reflectance 0.20
% Ceiling Rcc
Lumens
111.69
339.29
563.74
754.34
811.90
595.64
288.96
91.02
13.32
0.00
0.00
120-130
130-140
140-150
150-160
160-170
170-180
70
Rw
Zonal Lumen Summary
Zone
0-30
0-40
0-60
0-90
% Walls
Zone
0-10
10-20
20-30
30-40
40-50
50-60
60-70
70-80
80-90
90-100
100-110
80
80
70
50
30
10
0
Rw
70 50 30 10
70 50 30 10
50 30 10
50 30 10
50 30 10
0
0
1
2
3
4
5
6
7
8
9
10
71
66
60
55
51
47
43
40
37
35
32
69
64
59
54
49
45
42
39
36
34
32
66
59
53
47
42
38
34
31
28
26
24
63
57
51
45
40
36
33
30
27
25
23
61
55
49
44
39
35
32
29
27
24
23
71
63
56
50
44
39
35
32
29
27
25
71
61
52
45
39
34
30
27
24
22
20
71
59
49
42
35
31
27
24
21
19
17
69
62
55
49
43
39
35
32
29
26
24
69
60
51
44
39
34
30
27
24
22
20
69
58
49
41
35
30
27
23
21
19
17
66
58
50
43
38
33
30
26
24
22
20
66
56
48
40
35
30
26
23
21
19
17
63
56
49
42
37
33
29
26
23
21
19
63
55
46
40
34
30
26
23
21
18
17
61
54
47
41
36
32
29
26
23
21
19
61
53
45
39
34
29
26
23
20
18
17
59
52
44
38
33
28
25
22
19
17
16
Zonal Lumen Summary
Zone
0-30
0-40
0-60
0-90
Lumens
1014.71
1769.06
3176.60
3569.90
% Lamp
16.9
29.5
52.9
59.5
% Fixture
28.4
49.5
88.9
100.0
Zone
90-120
90-130
90-150
90-180
0-180
Lumens
0.25
0.70
1.39
1.50
3571.40
% Lamp
0.0
0.0
0.0
0.0
59.5
% Fixture
0.0
0.0
0.0
0.0
100.0
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
Mercmaster™ III Induction Luminaire 165 W Photometric Data
Enclosed and Gasketed. For Hazardous and Adverse Locations
Total Luminaire Efficiency = 70.7%
CIE Type – General Diffuse
REPORT NUMBER: KPB165QLG
Lamps: 165 W QL lamp with Globe only
Coefficients of Utilization - Zonal Cavity Method
Effective Floor Cavity Reflectance 0.20
% Ceiling Rcc
% Walls
110-120
758.05
120-130
130-140
140-150
150-160
160-170
170-180
568.50
328.65
119.26
15.42
0.71
0.05
Total Luminaire Efficiency = 58.5%
CIE Type – Direct
Plane
Spacing
Criteria
0-180
1.34
90-270
1.34
Diagonal
1.56
Lumens
149.58
419.79
669.69
893.40
1052.06
1151.10
1157.87
920.80
462.02
95.45
12.02
10.92
120-130
130-140
140-150
150-160
160-170
170-180
11.39
11.34
5.50
1.16
0.07
0.12
30
10
0
70 50 30 10
50 30 10
50 30 10
50 30 10
0
0
1
2
3
4
5
6
7
8
9
10
77
66
59
53
48
44
40
37
34
32
30
72
61
54
49
44
40
37
34
31
29
27
62
49
40
34
30
26
23
21
19
17
16
53
41
34
28
25
22
19
17
16
15
13
45
33
27
23
20
17
16
14
13
12
11
77
62
52
44
38
34
30
27
24
22
20
77
57
46
38
32
27
23
20
18
16
14
77
54
41
32
26
22
19
16
14
12
11
72
57
48
41
36
31
28
25
22
20
19
72
53
42
35
29
25
22
19
17
15
13
72
50
38
30
24
20
17
15
13
11
10
62
46
36
30
25
21
18
16
14
13
12
62
43
33
26
21
17
15
13
11
10
9
53
38
30
25
21
18
15
14
12
11
10
53
36
27
22
17
15
12
11
9
8
7
45
32
25
20
17
14
12
11
10
9
8
45
30
22
18
14
12
10
8
7
7
6
41
26
19
15
11
9
8
7
6
5
4
Zonal Lumen Summary
Zone
0-30
0-40
0-60
0-90
Lumens
497.77
933.23
2229.28
4898.92
% Lamp
4.1
7.8
18.6
40.8
% Fixture
5.9
11.0
26.3
57.7
Zone
90-120
90-130
90-150
90-180
0-180
Lumens
2553.16
3121.65
3569.56
3585.75
8484.67
% Lamp
21.3
26.0
29.7
29.9
70.7
% Fixture
30.1
36.8
36.8
42.3
100.0
REPORT NUMBER: KPB165QLST
Lamps: 165 W QL lamp with Standard Dome Reflector
Coefficients of Utilization - Zonal Cavity Method
Effective Floor Cavity Reflectance 0.20
% Ceiling Rcc
% Walls
Zone
0-10
10-20
20-30
30-40
40-50
50-60
60-70
70-80
80-90
90-100
100-110
110-120
50
70 50 30 10
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
80
70
50
30
10
0
Rw
70 50 30 10
70 50 30 10
50 30 10
50 30 10
50 30 10
0
0
1
2
3
4
5
6
7
8
9
10
69
61
55
49
44
41
37
34
32
30
28
68
59
53
47
43
39
36
33
31
29
27
64
53
45
39
34
30
27
24
22
20
18
61
51
43
37
32
28
25
23
21
19
18
59
48
41
35
31
27
24
22
20
19
17
69
58
49
42
36
32
29
26
23
21
20
69
54
44
36
30
26
23
20
18
16
15
69
51
40
32
26
22
19
16
14
13
11
68
56
47
41
35
31
28
25
23
21
19
68
53
43
35
30
26
22
20
18
16
14
68
50
39
31
26
21
18
16
14
12
11
64
51
41
34
29
25
22
19
17
16
14
64
49
38
30
25
21
18
16
14
12
11
61
49
40
33
28
24
21
19
17
15
14
61
47
37
30
25
21
18
16
14
12
11
59
47
38
32
27
23
21
18
16
15
14
59
45
36
29
24
20
18
15
14
12
11
57
44
34
27
23
19
16
14
12
11
10
Zonal Lumen Summary
Zone
0-30
0-40
0-60
0-90
Lumens
1239.06
2132.46
4335.62
6876.32
% Lamp
10.3
17.8
36.1
57.3
% Fixture
17.6
30.4
61.7
97.9
Zone
90-120
90-130
90-150
90-180
0-180
Lumens
118.39
129.78
146.62
147.97
7024.28
% Lamp
1.0
1.1
1.2
1.2
58.5
% Fixture
1.7
1.8
1.8
2.1
100.0
1053
Lighting: Enclosed and Gasketed — Area — LED/Induction
Lumens
57.43
158.04
282.31
435.46
580.50
715.54
829.63
904.70
935.31
924.84
870.28
70
Rw
Lighting
Zone
0-10
10-20
20-30
30-40
40-50
50-60
60-70
70-80
80-90
90-100
100-110
80
Mercmaster™ III Induction Luminaire 165 W Photometric Data
Enclosed and Gasketed. For Hazardous and Adverse Locations
Total Luminaire Efficiency = 61.4%
CIE Type – Direct
Plane
Spacing
Criteria
0-180
1.80
90-270
1.44
Diagonal
1.54
REPORT NUMBER: KPB165QLAN
Lamps: 165 W QL lamp with 30° Angle Dome Reflector
Coefficients of Utilization - Zonal Cavity Method
Effective Floor Cavity Reflectance 0.20
% Ceiling Rcc
Lighting: Enclosed and Gasketed — Area — LED/Induction
Lighting
% Walls
Zone
0-10
10-20
20-30
30-40
40-50
50-60
60-70
70-80
80-90
90-100
100-110
110-120
Lumens
163.07
462.54
734.69
975.82
1085.22
1057.29
951.20
800.34
592.90
347.00
139.87
32.59
120-130
130-140
140-150
150-160
160-170
170-180
12.93
8.39
3.34
1.19
0.88
0.20
Total Luminaire Efficiency = 61.6%
CIE Type – Direct
Plane
Spacing
Criteria
0-180
1.64
90-270
1.64
Diagonal
1.62
Lumens
216.27
655.22
1103.32
1536.15
1689.60
1298.60
664.63
201.70
26.23
0.27
0.00
110-120
0.00
120-130
130-140
140-150
150-160
160-170
170-180
0.00
0.00
0.00
0.00
0.00
0.00
1054
70
50
30
10
0
Rw
70 50 30 10
70 50 30 10
50 30 10
50 30 10
50 30 10
0
0
1
2
3
4
5
6
7
8
9
10
72
64
57
52
47
43
39
36
34
32
30
70
61
55
49
45
41
38
35
33
30
29
66
54
46
40
35
31
28
25
23
21
20
62
51
44
38
33
30
27
24
22
20
19
58
48
41
36
31
28
25
23
21
19
18
72
60
51
44
39
34
31
28
25
23
21
72
56
46
38
33
28
25
22
20
18
16
72
53
42
34
28
24
20
18
16
14
13
70
58
49
43
38
33
30
27
24
22
21
70
55
45
37
32
28
24
21
19
17
16
70
52
41
33
28
23
20
18
16
14
12
66
52
43
36
31
26
23
21
19
17
15
66
50
39
32
27
23
20
17
15
14
12
62
49
40
34
29
25
22
20
18
16
15
62
47
38
31
26
22
19
17
15
13
12
58
46
38
32
28
24
21
19
17
16
14
58
45
36
30
25
21
19
16
14
13
12
57
43
34
28
23
20
17
15
13
12
11
Zonal Lumen Summary
Zone
0-30
0-40
0-60
0-90
Lumens
1360.30
2336.12
4478.63
6823.08
% Lamp
11.3
19.5
37.3
56.9
% Fixture
18.5
31.7
60.8
92.6
Zone
90-120
90-130
90-150
90-180
0-180
Lumens
519.46
532.39
544.12
546.38
7369.46
% Lamp
4.3
4.4
4.5
4.6
61.4
% Fixture
7.0
7.2
7.2
7.4
100.0
REPORT NUMBER: KPB165QLHB
Lamps: 165 W QL lamp with High Bay Reflector
Coefficients of Utilization - Zonal Cavity Method
Effective Floor Cavity Reflectance 0.20
% Ceiling Rcc
% Walls
Zone
0-10
10-20
20-30
30-40
40-50
50-60
60-70
70-80
80-90
90-100
100-110
80
80
70
50
30
10
0
Rw
70 50 30 10
70 50 30 10
50 30 10
50 30 10
50 30 10
0
0
1
2
3
4
5
6
7
8
9
10
73
68
62
57
52
48
44
41
38
35
33
72
66
61
55
51
47
43
40
37
34
32
68
61
54
48
43
38
34
31
28
26
24
66
59
52
46
41
37
33
30
28
25
23
63
57
50
45
40
36
32
29
27
25
23
73
65
58
51
45
40
36
33
30
27
25
73
63
54
46
40
35
31
27
24
22
20
73
61
51
42
36
31
27
24
21
19
17
72
64
56
50
44
40
36
32
29
27
25
72
62
53
46
39
35
30
27
24
22
20
72
60
50
42
36
31
27
24
21
19
17
68
60
51
44
39
34
30
27
24
22
20
68
58
49
41
35
30
27
23
21
19
17
66
58
50
43
38
33
29
26
24
21
19
66
56
48
41
35
30
26
23
21
18
17
63
56
48
42
37
33
29
26
23
21
19
63
55
47
40
34
30
26
23
20
18
17
62
53
45
39
33
29
25
22
19
17
15
Zonal Lumen Summary
Zone
0-30
0-40
0-60
0-90
Lumens
1974.81
3510.96
6499.16
7391.72
% Lamp
16.5
29.3
54.2
61.6
% Fixture
26.7
47.5
87.9
100.0
Zone
90-120
90-130
90-150
90-180
0-180
Lumens
0.27
0.27
0.27
0.27
7391.99
% Lamp
0.0
0.0
0.0
0.0
61.6
% Fixture
0.0
0.0
0.0
0.0
100.0
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
Mercmaster™ III Low Profile Compact Fluorescent Luminaires
Enclosed and Gasketed. For Hazardous and Wet Locations
Compact Fluorescent listed for simultaneous exposure to combustible dusts and flammable gases or vapors.
Class I, Division 2, Groups A, B, C, D
Class I, Zone 2, AEx nA nR IIC (Z2)
Class I, Zone 2, Ex nR IIC (Z) V
Class II, Division 1 and 2, Groups E, F, G
Class III
Simultaneous Exposure (Class I, Division 2/
Class II, Division 1)
Fixtures Outside Type (Salt Water)
Type 4X
IP66
Applications
• Enclosed and gasketed fixtures suitable for use in marine
and wet locations, and in a wide range of industrial, chemical
processing and other areas where flammable gases and vapors
or combustible dusts are present under conditions defined
by the National Electrical Code as Class I, Division 2; Class II,
Division 1 and 2; and Class III. The method of protection for
the Zone 2 Mercmaster is AEx nA nR – Restricted Breathing/
Nonsparking.
• For use in areas of low clearance, low ceiling heights or where
fixture weights must be minimized.
• Suited for use in non-hazardous locations where severe
weather conditions, excessive moisture, dirt, dust or corrosive
atmospheres are present.
• Typical applications include oil refineries, pulp and paper mills,
chemical plants, food-processing areas, inspection facilities,
foundries, power plants, storage areas, waste and sewage
treatment, parking garages, and other areas where dust, water,
dirt and rough usage are a problem.
Features
Ceiling Mount Fixture with
Prismatic Glass Refractor
Standard Materials
• Standard dome or 30° angle reflectors: highly reflective
fiberglass reinforced white polyester to provide strength,
corrosion resistance and excellent photometrics
• Fixture housing, mounting hoods, and guards: die-cast,
copperfree (4/10 of 1% max.) aluminum with epoxy finish for
corrosion resistance
• Exposed hardware: stainless steel. Latch assemblies have
stainless steel bolt and captive nut; reflectors and guards attach
with stainless steel screws threading into stainless steel inserts
• Globes and glass refractors: heat-resistant prismatic glass
• Polymeric refractor: spun aluminum reflector and a lens made of
an engineered thermoplastic
Standard Finishes
Options
• Fuse can be field installed. Kits include fuse block, wire
connectors and screws for attachment to mounting hood.
— Fixtures with fuses do not comply with UL 1598A for marine
listing
— Canadian Electrical Code does NOT allow fusing in
hazardous locations V
• Guards with gray epoxy painted to match fixtures, supplied with
stainless steel screws. Add suffix -G.
• Reflectors are available as standard dome and 30° angle
polyester. Order separately.
Certifications and Compliances
• UL Standard: UL 1598, UL 1598A, UL 844, UL 60079-0, UL
60079-15
• UL Listed: E10444
• CSA Standard: C22.2 No. 250, C22.2 No. 137, CAN E60079-0,
CAN E60079-15
• CSA Certified: 025428
1055
Lighting: Enclosed and Gasketed — Area — Fluorescent
• Epoxy powder coat finish electrostatically applied for complete,
uniform surface protection
V CSA Certification Only.
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
Lighting
• Energy-efficient, compact fluorescent light sources possess
superior lamp efficiency.
• Fluorescent provides long lamp life, thereby reducing
relamping costs.
• “Instant on” nature of this electronically ballasted fluorescent
eliminates the possibility of an extended blackout due to a
momentary power dip.
• High efficacies (up to 75 lumens per Watt) offer a desirable
low-glare/instant-on alternative to low wattage HID sources.
• High output under widely varying conditions: Greater than 90%
of rated lumens in ambient temperatures from 23 °F to 130 °F /
-5 °C to 54 °C.
• Excellent color rendering (82 CRI) makes it the best choice for
food processing and inspection facilities.
• A wide variety of lamp wattages:
26 W, 32 W, 42 W, 52 W, 64 W, 84 W.
• Electronic ballast permits low operating costs with power factor
greater than 99%. Also allows flicker-free starting.
• Cold weather starting to a minimum temperature of 0°F/ -18°C.
• Fixtures are available for operation from an external 125 Vdc
source.
• Compact, light-weight low profile design creates ease of
installation and maintenance.
• Modular design, with multiple mounting hoods, optics and
reflectors, permits a wide array of fixtures to meet installation
and lighting needs.
• Body gaskets and optic gaskets are high temperature silicone
O-Rings that provide superior sealing.
• Mounting hoods have a high hinge for added safety during
installation and servicing.
• Choice of heat-resistant prismatic glass refractor (NEMA I, III
or V), heat-resistant clear globes, color globes or polymeric
refractors (NEMA II, III, IV or V). (Polymeric refractors are not
listed for Zone 2.)
Pendant Mount Fixture
with Glass Globe
Mercmaster™ III Low Profile Compact Fluorescent Luminaires
Enclosed and Gasketed. For Hazardous and Wet Locations
Compact Fluorescent listed for simultaneous exposure to combustible dusts and flammable gases or vapors.
Class I, Division 2, Groups A, B, C, D
Class I, Zone 2, AEx nA nR IIC (Z2)
Class I, Zone 2, Ex nR IIC (Z) V
Class II, Division 1 and 2, Groups E, F, G
Class III
Simultaneous Exposure (Class I, Division 2/
Class II, Division 1)
Fixtures Outside Type (Salt Water)
Type 4X
IP66
Illustrated Features
Ballast Assembly
Utilizing non-sparking components
avoiding the ignition of gases or vapors
that may be present (nA).
Lighting: Enclosed and Gasketed — Area — Fluorescent
Lighting
Globe Chamber
Completely sealed from the ballast
housing and outside vapors/air (nA nR).
Vented Reflectors
Reflectors are thick, tough fiberglass-
reinforced white polyester, vented for
cooler operation. Quickly attach with
furnished stainless steel screws.
Epoxy Finish
Ballast housing, hoods and guards are
copperfree aluminum with epoxy powder
coat finish.
Terminal Blocks (Zone 2)
A seven-point terminal block is provided
to facilitate wiring. Terminal block
accommodates wire size ranging from #8
to #24 AWG.
Photocell
Installs through knock-out in mounting
hoods except cone and ceiling mount.
Provides continuous on-off dusk-to-
dawn control. Not for use in hazardous
(classified) areas. Hazardous location
rated photocells also available. See
Accessories page.
Stainless Steel Inserts
Ballast bodies have stainless steel
threaded inserts to receive stainless steel
screws for reflectors and guard. Prevents
"freezing”, allowing guards and reflectors
to be easily removed and replaced at any
time, without damage to the housing.
Hood/Ballast Gasket
Silicone rubber gasket seals out moisture,
dirt and dust. Stays flexible, withstands
high temperatures. Closure design
assures uniform gasket compression.
Electrical Protection
Ground wire provided to bond mounting
hood to ballast housing.
Cooler Operating Cone Hood
Larger sloped surface sheds dusts, dirt
and combustible fibers providing better
heat dissipation.
Prismatic Glass Globes and Refractors
Heat-resistant globes and glass refractors
and polymeric refractors thread directly
into ballast housing and seal against a
high temperature silicone rubber gasket.
(Polymeric refractors are not listed for
Zone 2 areas.)
Fuses
Two screws secure fuse kit to mounting
boss in any Mercmaster mounting hood.
Fuse included.
Stainless Steel Latch Assembly
Captive, stainless steel latch assembly
bolt and nut closes securely, resists attack
of corrosive atmospheres. Swing-away
design simplifies servicing.
"Safety" High
Hinge
Extra-high hinge
provides additional
protection against
accidental
ballast housing
disengagement
during installation
or maintenance.
V CSA Certification Only.
1056
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
Mercmaster™ III Low Profile Compact Fluorescent Luminaire Family Tree
Enclosed and Gasketed. For Hazardous and Wet Locations
Compact Fluorescent listed for simultaneous exposure to combustible dusts and flammable gases or vapors.
Mounting Hoods
Mounting Hoods
Pendant
Pendant
KPA-75
KPA-75
KPA-100
KPA-100
Pendant
PendantCone
Cone
KPCH-75
KPCH-75
KPCH-100
KPCH-100
Ceiling
Ceiling
KPC-75
KPC-75
KPC-100
KPC-100
25°
25°Stanchion
Stanchion
90°90°Stanchion
Stanchion
KPS-125
KPS-75
KPS-100
KPS-150
KPST-125
KPST-75
KPST-100
KPST-150
Globe or Polymeric
Refractor
Ballast Housings
MLBG26FBU
(26 W)
Globe
or Polymeric
MLBG32FBU (32 W)
Refractor
MLBG42FBU (42 W)
Ballast
Housings
MLBG52FBU
(52 W)
MLBG32F
32W)
MLBG57FBU(26
(57&W)
V
MLBG64F
(52(64
& 64W)
MLBG64FBU
W)
MLBG84FBU (84 W)
MLBG114FBU (114 W) V
Ballast
Housing
Ballast
Housing
KPWB-75
KPWB-75
KPWB-100
KPWB-100
8” Glass Refractor
Ballast Housings
8"
Glass Refractor
MLBR26FBU (26 W)
Ballast
Housings
MLBR32FBU
(32 W)
MLBR26F(42
(26W)
MLBR42FBU
W)
MLBR32F(52
(32W)
MLBR52FBU
W)
MLBR52F
(52W)
MLBR57FBU
(57W)
V
MLBR64FBU
W)
MLBR64F(64
(64W)
MLBR84FBU (84 W)
MLBR114FBU (114 W) V
Polyester Reflectors
Polyester Reflectors
Polyester Reflectors
Standard
Standard Dome
Dome
CMR-4ST
CMR-4ST
30°
30°Angle
Angle
CMR-4AN
CMR-4AN
30°Angle
Angle
30°
KR2-AN
KR2-AN
Glass Refractors
Glass Refractors
NEMA I
LPG-R1
NEMA
NEMA
III 1 LPG-R1
LPG-R3
NEMA
NEMA
V 3 LPG-R3
LPG-R5
NEMA 5 LPG-R5
Polymeric Refractors
Polymeric
Refractors
NEMA
II 2 LPRF-2CP
LPRF-2CP
NEMA
NEMA
III 3 LPRF-3CP
LPRF-3CP
NEMA
NEMA
IV 4 LPRF-4CP
LPRF-4CP
NEMA
NEMA
V 5 LPRF-5CP
LPRF-5CP
NEMA
Aluminum Guard
Guard
Aluminum
GlobeGuard
Guard
Globe
KGU2
KGU2
Three-Way
Three-Way
Exit Sign
Exit
Sign
CJEXR
CJEXRN
Aluminum Guard
Aluminum
Guard
GlassRefractor
Refractor Guard
Glass
Guard
KRG2
KRG2
V CSA Certification Only.
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
1057
Lighting: Enclosed and Gasketed — Area — Fluorescent
Standard
Dome
Standard Dome
KR2-ST
KR2-ST
Lighting
Polyester Reflectors
GlassGlobes
Globes
Glass
Clear
VPGL-2HR
Clear VPGL-2HR
Amber
VPGL-2AM
Amber VPGL-2AM
Blue
VPGL-2BL
Blue
VPGL-2BL
Green
VPGL-2GR
Green VPGL-2GR
Red
VPGL-2RE
Red
VPGL-2RE
Wall
WallMount
Mount
Mercmaster™ III Low Profile Compact Fluorescent Luminaires
Enclosed and Gasketed. For Hazardous and Wet Locations
Class I, Division 2, Groups A, B, C, D
Class I, Zone 2, AEx nA nR IIC (Z2)
Class I, Zone 2, Ex nR IIC (Z) V
Class II, Division 1 and 2, Groups E, F, G
Class III
Simultaneous Exposure (Class I, Division 2/
Class II, Division 1)
Fixtures Outside Type (Salt Water)
Type 4X
IP66
Order using catalog numbering guide below or select catalog number from tables on following pages.
Catalog Numbering Guide For Zone 2 Mercmaster III Compact Fluorescent Luminaires
ML
Series:
ML Mercmaster
III
Low Profile
A
F
Lighting
2
G2
G
BU
L
Z2
Guard Options:
Lamp Options:
Hub Size:
2 - 3/4” NPT
G - Cast Guard
L - Lamp(s) included
3 - 1” NPT
(Glass Refractor
Blank - Lamp(s)
4 - 1-1/4” NPT
& Globe only)
excluded
Stanchion
N - No Guard
5 - 1-1/2” NPT
Stanchion
Wattage:
Voltage:
Suffix:
Optical Assembly: ➊
26 - One 26 Watt PL-T
BU - 120 to 277 V,
DP - Safety Cable
G2 - VPGL2HR Globe
32 - One 32 Watt PL-T
50/60 Hz
SC - Safety Chain
(not for 57, 114 Watt)
42 - One 42 Watt PL-T
and 125 Vdc
Z2 - Zone 2 Suffix
G4 - VPGL4HR Globe
52 - Two 26 Watt PL-T
A5 - 347 V, 60 Hz V
(Required for
(57, 114 Watt only) V
57 - One 57 Watt PL-T V J1 - NEMA I Glass Refractor
AEx nA nR rating)
64 - Two 32 Watt PL-T
B - Battery Back-up ➍V
J3 - NEMA III Glass Refractor
84 - Two 42 Watt PL-T
(42 W max.)
J5 - NEMA V Glass Refractor
114 - Two 57 Watt PL-T V P2 - NEMA II Polymeric Refractor
C - Safety Cable V
F - Fused Mtg. Hood ➌V
P3 - NEMA III Polymeric
(Non-Haz. Loc. only)
Refractor
P - Non-Haz. Photocell
P4 - NEMA IV Polymeric
(Specify Voltage) V
Refractor
Q - Division 2 Haz.
P5 - NEMA V Polymeric
Photocell (Specify
Refractor
Voltage) V
T - Terminal Blocks V
V - Vibration Protection V
X - Appledapter ➋
Mounting Hood
Adapter V
Z - Zone 2 suffix
(required for
Ex nR) V
Lamp Type:
F - Fluorescent
Mounting Hood:
A - Pendant
(Rigid or Flexible)
C - Ceiling
D - Pendant Cone
R - 90º Stanchion
S - 25º Stanchion
W - Wall
Lighting: Enclosed and Gasketed — Area — Fluorescent
84
➊ Polymeric refractors suitable for Class II, Groups F & G; NEMA 4X; and Marine Type Electric Fixture Outside Type (Salt Water) only.
Reflectors ordered separately (for use with globe fixtures only): Standard Dome: KR2-ST 30-degree Angle: KR2-AN
➋ Appledapter is available for use with the pendant, ceiling and angled stanchion mounting only.
➌ Canadian Electrical Code does NOT allow fusing in hazardous locations V.
➍ Provides a minimum 90 minute back-up power supply in the case of a power loss. Will keep one lamp lit at approximately 50% of its full output (42 W
maximum) V.
V CSA Certification only.
1058
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
Mercmaster™ III Low Profile Compact Fluorescent Luminaire Thermal Performance
Class I, Division 2; Class II, Division 1; Simultaneous Exposure to Hazardous Conditions
Temperature identification numbers of Mercmaster III Low Profile Fluorescent Fixtures
Class I, Division 2, Groups A, B, C, D
Class I, Zone 2, AEx nA nR IIC (Z2)
Class I, Zone 2, Ex nR IIC (Z) V
Lamp
Watts
Ambient
Temp
(°F/°C) ➊
Globe
26
104/40
T3
Class II, Division 1 and 2, Groups E, F, G
Class III
Simultaneous Exposure (Class I, Division 2/
Class II, Division 1)
Class I, Division 2
Globe &
Glass
Polymeric
Reflector Refractor Refractor
T3
T3
Class II, Division 1
Groups E, F and G ➋
Globe &
Glass
Polymeric
Reflector Refractor Refractor
Globe
T5
—
Fixtures Outside Type (Salt Water)
Type 4X
IP66
T5
T5
T6
Simultaneous Exposure
(Class I, Div 2 and Class II, Division 1)
Globe &
Glass
Polymeric
Globe
Reflector Refractor Refractor
T3
T3
T3
—
32
104/40
T3
T3
T3
—
T5
T5
T5
T6
T3
T3
T3
—
42
104/40
T3
T3
T3
—
T5
T5
T5
T6
T3
T3
T3
—
52
104/40
T2D
T2D
T3
—
T4A
T4A
T4A
T6
T2C
T2C
T2C
—
57 V
104/40
T2D
T2D
T3
—
T4A
T4A
T4A
T6
—
—
—
—
64
104/40
T2D
T2D
T3
—
T4A
T4A
T4A
T6
T2C
T2C
T2C
—
84
104/40
T2C
T2C
T2D
—
T3C
T3C
T3C
T6
T2B
T2B
T2B
—
114 V
104/40
T2C
T2C
T2D
—
T3C
T3C
T3C
T6
—
—
—
—
“T” Numbers Represent the Maximum Lamp Temperature for Class I, Division 2 Locations and
Maximum Surface Temperature Under Dust Blanket for Class II, Division 1 Locations.
“T” Number
Temp. Range (˚ºF)
Temp. Range (°C)
T1
350
325
T2
T2A
T2B
T2C
T2D
T3
T3A
T3B
T3C
T4
T4A
T5
664842
351450
619662
326-
350
574617
301-
325
538572
281-
300
502536
261-
280
448500
231-
260
421446
216-
230
394419
201215
358392
181-
200
331356
166-
180
322329
161165
277320
136160
250275
121135
214248
101-
120
187212
86-
100
T6
185
85
Lighting
Class I, Zone 2, AEx nA nR — Ex nR
Globe & Reflector
Refractor
Supply Wire Temp.
(°F/°C)
Ambient Temp.
(°F/°C)
Globe
26
167/75
104/40
T5
T5
T6
32
167/75
104/40
T5
T5
T6
42
167/75
104/40
T5
T5
T6
52
167/75
104/40
T5
T5
T6
57 V
167/75
104/40
T6
T6
T6
64
167/75
104/40
T5
T5
T6
84
167/75
104/40
T5
T5
T6
114 V
167/75
104/40
T6
T6
T6
Lighting: Enclosed and Gasketed — Area — Fluorescent
Lamp
Watts
“T” Numbers Represent the Maximum Surface Temperature for Luminaries with AEx nA nR Rating
“T”
Number
T1
T2
T3
T4
T5
T6
Temperature
Range (˚ºF)
574-842
394-572
277-392
214-275
187-212
185
Temperature
Range (°C)
301-450
201-300
136-200
101-135
86-100
85
➊ Use 167 °F/75 °C rated supply wire.
➋ Fixtures with Polymeric Refractor are listed for Groups F and G only.
V CSA Certification only.
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
1059
Mercmaster™ III Low Profile Compact Fluorescent Luminaires
Enclosed and Gasketed. For Hazardous and Wet Locations
High Power Factor Electronic Ballast (Min. P.F. 99%), PL-T Lamps.
Class I, Division 2, Groups A, B, C, D
Class I, Zone 2, AEx nA nR IIC (Z2)
Class I, Zone 2, Ex nR IIC (Z) V
Class II, Division 1 and 2, Groups E, F, G
Class III
Simultaneous Exposure (Class I, Division 2/
Class II, Division 1)
Lamp
Watts
Hub
Size
(Inches)
Fixtures Outside Type (Salt Water)
Type 4X
IP66
Catalog Numbers ➋➌
With Globe
➊➍
With Type V
8” Glass Refractor ➊➍➎
With Type V
Polymeric Refractor ➏
MLAF262G2N
MLAF262J5N
MLAF262P5N
Pendant — One Hub (Rigid or Flexible Mounting)
1 x 26 W
1 x 32 W
1 x 42 W
2 x 26 W
1 x 57 W
2 x 32 W
Shown with Glass Globe
2 x 42 W
Lighting
2 x 57 W
1
MLAF263G2N
MLAF263J5N
MLAF263P5N
3/4
MLAF322G2N
MLAF322J5N
MLAF322P5N
1
MLAF323G2N
MLAF323J5N
MLAF323P5N
3/4
MLAF422G2N
MLAF422J5N
MLAF422P5N
1
MLAF423G2N
MLAF423J5N
MLAF423P5N
3/4
MLAF522G2N
MLAF522J5N
MLAF522P5N
1
3/4
1
3/4
MLAF523G2N
MLAF523J5N
MLAF523P5N
MLAF572G4N V
MLAF572J5N V
MLAF572P5N V
MLAF573G4N V
MLAF572J5N V
MLAF572P5N V
MLAF642G2N
MLAF642J5N
MLAF642P5N
1
MLAF643G2N
MLAF643J5N
MLAF643P5N
3/4
MLAF842G2N
MLAF842J5N
MLAF842P5N
MLAF843G2N
MLAF843J5N
MLAF843P5N
3/4
MLAF1142G4N V
MLAF1142J5N V
MLAF1142P5N V
1
MLAF1143G4N V
MLAF1143J5N V
MLAF1143P5N V
3/4
MLDF262G2N
MLDF262J5N
MLDF262P5N
1
MLDF263G2N
MLDF263J5N
MLDF263P5N
3/4
MLDF322G2N
MLDF322J5N
MLDF322P5N
1
MLDF323G2N
MLDF323J5N
MLDF323P5N
1
Pendant Cone — One Hub (Rigid or Flexible Mounting)
1 x 26 W
1 x 32 W
Lighting: Enclosed and Gasketed — Area — Fluorescent
3/4
1 x 42 W
2 x 26 W
1 x 57 W
2 x 32 W
Shown with 8” Glass Refractor
2 x 42 W
2 x 57 W
3/4
MLDF422G2N
MLDF422J5N
MLDF422P5N
1
MLDF423G2N
MLDF423J5N
MLDF423P5N
3/4
MLDF522G2N
MLDF522J5N
MLDF522P5N
1
MLDF523G2N
MLDF523J5N
MLDF523P5N
3/4
MLDF572G4N V
MLDF572J5N V
MLDF572P5N V
1
MLDF573G4N V
MLDF573J5N V
MLDF573P5N V
3/4
MLDF642G2N
MLDF642J5N
MLDF642P5N
1
MLDF643G2N
MLDF643J5N
MLDF643P5N
3/4
MLDF842G2N
MLDF842J5N
MLDF842P5N
1
MLDF843G2N
MLDF843J5N
MLDF843P5N
3/4
MLDF1142G4N V
MLDF1142J5N V
MLDF1142P5N V
1
MLDF1143G4N V
MLDF1143J5N V
MLDF1143P5N V
➊ For fixtures with guard, substitute G for N before adding voltage suffix.
➋ Add voltage suffix -BU for 120 through 277 V, 50/60 Hz and 125 Vdc. Add voltage suffix -A5 for 347 V, 60 Hz.
➌ Add L after voltage suffix to include lamp.
➍ Add Z2 suffix for factory-sealed non-sparking/restricted breathing protection (Aex nA nR).
➎ To order fixture with NEMA Type I or III glass refractor, change J5 to J1 or J3 respectively.
➏ To order fixture with NEMA Type II, III, or IV polymeric refractor, change P5 to P2, P3 or P4 respectively. Polymeric refractor fixtures are UL Listed and CSA
Certified for Class II, Division 1 and 2, Groups F and G; Class III; Marine Outdoor Salt Water (UL1598A); NEMA 4X and CSA Type 4X.
V CSA Certification only.
1060
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
Mercmaster™ III Low Profile Compact Fluorescent Luminaires
Enclosed and Gasketed. For Hazardous and Wet Locations
High Power Factor Electronic Ballast (Min. P.F. 99%), PL-T Lamps.
Class I, Division 2, Groups A, B, C, D
Class I, Zone 2, AEx nA nR IIC (Z2)
Class I, Zone 2, Ex nR IIC (Z) V
Class II, Division 1 and 2, Groups E, F, G
Class III
Simultaneous Exposure (Class I, Division 2/
Class II, Division 1)
Lamp
Watts
Fixtures Outside Type (Salt Water)
Type 4X
IP66
Catalog Numbers ➋➌
Hub
Size
(Inches)
With Globe
➊➍
3/4
MLCF262G2N
With Type V
8” Glass Refractor ➊➍➎
With Type V
Polymeric Refractor ➏
Ceiling — Five Hubs, Four Close-Up Plugs
1 x 26 W
1 x 32 W
1 x 42 W
2 x 26 W
1 x 57 W
2 x 32 W
Shown with Polymeric Refractor
2 x 42 W
2 x 57 W
MLCF262J5N
MLCF262P5N
1
MLCF263G2N
MLCF263J5N
MLCF263P5N
3/4
MLCF322G2N
MLCF322J5N
MLCF322P5N
1
MLCF323G2N
MLCF323J5N
MLCF323P5N
3/4
MLCF422G2N
MLCF422J5N
MLCF422P5N
1
MLCF423G2N
MLCF423J5N
MLCF423P5N
3/4
MLCF522G2N
MLCF522J5N
MLCF522P5N
1
3/4
1
3/4
MLCF523G2N
MLCF523J5N
MLCF523P5N
MLCF572G4N V
MLCF572J5N V
MLCF572P5N V
MLCF573G4N V
MLCF573J5N V
MLCF573P5N V
MLCF642G2N
MLCF642J5N
MLCF642P5N
1
MLCF643G2N
MLCF643J5N
MLCF643P5N
3/4
MLCF842G2N
MLCF842J5N
MLCF842P5N
MLCF843J5N
MLCF843P5N
MLCF1142G4N V
MLCF1142J5N V
MLCF1142P5N V
1
MLCF1143G4N V
MLCF1143J5N V
MLCF1143P5N V
3/4
MLWF262G2N
MLWF262J5N
MLWF262P5N
1
MLWF263G2N
MLWF263J5N
MLWF263P5N
3/4
MLWF322G2N
MLWF322J5N
MLWF322P5N
1
Wall Bracket — Five Hubs, Four Close-Up Plugs
1 x 26 W
1 x 32 W
2 x 26 W
1 x 57 W
2 x 32 W
Shown with 8” Glass Refractor
2 x 42 W
2 x 57 W
MLWF323G2N
MLWF323J5N
MLWF323P5N
MLWF422G2N
MLWF422J5N
MLWF422P5N
1
MLWF423G2N
MLWF423J5N
MLWF423P5N
3/4
MLWF522G2N
MLWF522J5N
MLWF522P5N
1
MLWF523G2N
MLWF523J5N
MLWF523P5N
3/4
MLWF572G4N V
MLWF572J5N V
MLWF572P5N V
1
MLWF573G4N V
MLWF573J5N V
MLWF573P5N V
3/4
MLWF642G2N
MLWF642J5N
MLWF642P5N
1
MLWF643G2N
MLWF643J5N
MLWF643P5N
3/4
MLWF842G2N
MLWF842J5N
MLWF842P5N
1
MLWF843G2N
MLWF843J5N
MLWF843P5N
3/4
MLWF1142G4N V
MLWF1142J5N V
MLWF1142P5N V
1
MLWF1143G4N V
MLWF1143J5N V
MLWF1143P5N V
➊ For fixtures with guard, substitute G for N before adding voltage suffix.
➋ Add voltage suffix -BU for 120 through 277 V, 50/60 Hz and 125 Vdc. Add voltage suffix -A5 for 347 V, 60 Hz.
➌ Add L after voltage suffix to include lamp.
➍ Add Z2 suffix for factory-sealed non-sparking/restricted breathing protection (Aex nA nR).
➎ To order fixture with NEMA Type I or III glass refractor, change J5 to J1 or J3 respectively.
➏ To order fixture with NEMA Type II, III, or IV polymeric refractor, change P5 to P2, P3 or P4 respectively. Polymeric refractor fixtures are UL Listed and CSA
Certified for Class II, Division 1 and 2, Groups F and G; Class III; Marine Outdoor Salt Water (UL1598A); NEMA 4X and CSA Type 4X.
V CSA Certification only.
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
1061
Lighting: Enclosed and Gasketed — Area — Fluorescent
1 x 42 W
1
3/4
Lighting
MLCF843G2N
3/4
Mercmaster™ III Low Profile Compact Fluorescent Luminaire Accessories
Enclosed and Gasketed. For Hazardous and Wet Locations
Compact Fluorescent listed for simultaneous exposure to combustible dusts and flammable gases or vapors.
Class I, Division 2, Groups A, B, C, D
Class I, Zone 2, AEx nA nR IIC (Z2)
Class I, Zone 2, Ex nR IIC (Z) V
Class II, Division 1 and 2, Groups E, F, G
Class III
Simultaneous Exposure (Class I, Division 2/
Class II, Division 1)
Description
Fixtures Outside Type (Salt Water)
Type 4X
IP66
Hub Size (Inches)
Catalog Number
Pendant
One Hub,
Rigid or Flexible Mounting
3/4
KPA-75
1
KPA-100
Five Hubs,
Four Close-Up Plugs
3/4
KPCH-75
1
KPCH-100
Five Hubs,
Four Close-Up Plugs
3/4
KPC-75
1
KPC-100
Five Hubs,
Four Close-Up Plugs
3/4
KPWB-75
1
KPWB-100
Pendant Cone
Ceiling
Lighting
Wall
25° Stanchion
One Hub
1-1/4
KPS-125
1-1/2
KPS-150
1-1/4
KPST-125
1-1/2
KPST-150
Lighting: Enclosed and Gasketed — Area — Fluorescent
90° Stanchion
One Hub
Ballast Bodies
Catalog Numbers
Lamp
Wattage
For Glass Globe or
Polymeric Refractor ➊➋
For Glass
Refractor ➋
1 x 26 W
MLBG26FBU
MLBR26FBU
1 x 32 W
MLBG32FBU
MLBR32FBU
1 x 42 W
MLBG42FBU
MLBR42FBU
2 x 26 W
MLBG52FBU
—
MLBR52FBU
1 x 57 W
2 x 32 W
2 x 42 W
2 x 57 W
MLBG64FBU
MLBG84FBU
—
MLBR64FBU
MLBR84FBU
Compact PL-T Fluorescent — 120 V to 277 V, 50/60 Hz and 125 Vdc
Ballast Body for Glass Globe
or Polymeric Refractor ➊
Ballast Body for
Glass Refractor
MLBR57F V
MLBR114F V
➊ Polymeric refractor not listed for Class I, Zone 2 areas.
➋ Add voltage suffix -BU for 120 through 277 V, 50/60 Hz and 125 Vdc. Add voltage suffix -A5 for 347 V, 60 Hz.
V CSA Certification only.
1062
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
Mercmaster™ III Low Profile Compact Fluorescent Luminaire Accessories
Enclosed and Gasketed. For Hazardous and Wet Locations
Compact Fluorescent listed for simultaneous exposure to combustible dusts and flammable gases or vapors.
Item
Description
Catalog Number ➌
White Polyester Reflectors – Furnished with stainless steel screws
For Globe Fixtures
Standard Dome
KR2-ST
30° Angle
KR2-AN
Standard Dome
For Glass Refractor Fixtures ➊
Standard Dome
CMR-4ST ➋
30° Angle
CMR-4AN ➋
30° Angle Dome
Prismatic Glass Globes — Heat-Resistant ➌
Clear
VPGL-2HR
Amber ➍
VPGL-2AM
Blue ➍
VPGL-2BL
Green ➍
VPGL-2GR
Red ➍
VPGL-2RE
Clear — 57/114 Watt V
VPGL-4HR
Lighting
Closed Prismatic Glass Refractors — All Heat-Resistant ➌
NEMA Type I
LPG-R1
NEMA Type III
LPG-R3
NEMA Type V
LPG-R5
NEMA Type II
LPRF-2CP
NEMA Type III
LPRF-3CP
NEMA Type IV
LPRF-4CP
NEMA Type V
LPRF-5CP
Globe Guard
KGU2
Glass Refractor Guard
KRG2
Globe Guard — 57/114 W V
KPGU400
Lighting: Enclosed and Gasketed — Area — Fluorescent
Closed Prismatic Polymeric Refractors — Not Listed for Class I, Zone 2 Areas
Guards
Globe Guard
Glass Refractor Guard
Globe Guard for 57 W Only
➊ Fixtures with refractors are not UL Listed when used with reflectors.
➋ Standard dome reflectors may interfere with bottom conduit entry if used with KPST and KPWB mounting hoods.
➌ Silicone or Teflon V coated globes are available. Contact your local sales representative.
➍ Non hazardous rated globes for special applications.
V CSA Certification only.
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
1063
Mercmaster™ III Low Profile Compact Fluorescent Luminaire Accessories
Enclosed and Gasketed. For Hazardous and Wet Locations
Compact Fluorescent listed for simultaneous exposure to combustible dusts and flammable gases or vapors.
Item
Description
Catalog Number
Replacement Optic Gaskets — Silicone rubber
Globe and Polymeric Refractor Gasket
VPGL-GK
Glass Refractor Gasket
KRF-GK
Replacement Lamp
Mercmaster III Low Profile Compact Fluorescent
Lamp Type
Lamp Base
Wattage
PL-T
GX24q-3
26
Catalog Number
PLT26
PL-T
GX24q-3
32
PLT32
PL-T
GX24q-4
42
PLT42
PL-T
GX24q-5
57
PLT57 V
Replacement Socket
For 26 W, 32 W and 42 W PLT Lamps listed above
PLT32RS
For 57 W PLT Lamp
PLT57RS V
Epoxy enameled steel – 6”/152.4 mm high red lettering
CJEXRN
Lighting
Three-Way Exit Sign ➊
Mounts to Globe Ballast Housing in place of guard.
Lighting: Enclosed and Gasketed — Area — Fluorescent
Single Sided Exit Sign ➊
Epoxy enameled steel – 6”/152.4 mm high red lettering
AEXR-15R
Mounts to Globe Ballast Housing in place of guard
Retrofit Pendant Mounting Adapter
Permits use of Mercmaster III pendant hood
with 3/4” hub on existing V-51 mounting hood
LPAD-1
Fuse Kit ➋
MLF2
2-Amp time delay fuse
➊ Consult your local sales representative for classified area suitability. Not listed for Zone 2 areas.
➋ Canadian Electrical Code does NOT allow fusing in hazardous locations V.
V CSA Certification only.
1064
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
Mercmaster™ III Low Profile Compact Fluorescent Luminaire Electrical Specifications
Enclosed and Gasketed. For Hazardous and Wet Locations
Compact Fluorescent listed for simultaneous exposure to combustible dusts and flammable gases or vapors.
Class I, Division 2, Groups A, B, C, D
Class I, Zone 2, AEx nA nR IIC (Z2)
Class I, Zone 2, Ex nR IIC (Z) V
Class II, Division 1 and 2, Groups E, F, G
Class III
Simultaneous Exposure (Class I, Division 2/
Class II, Division 1)
Line Voltage
Fixtures Outside Type (Salt Water)
Type 4X
IP66
Total Watts
Electronic
Electronic
Electronic
.250
.110
.080
28
28
27
Electronic
Electronic
Electronic
.300
.130
.150
36
36
36
Electronic
Electronic
Electronic
.410
.180
.140
48
48
43
Electronic
Electronic
Electronic
.460
.220
.170
56
56
54
Electronic
Electronic
Electronic
.480
.210
.180
58
57
61
Electronic
Electronic
Electronic
.580
.260
.190
69
69
66
Electronic
Electronic
Electronic
.760
.320
.280
91
91
86
Electronic
Electronic
Electronic
.960
.420
.360
116
114
122
Lighting: Enclosed and Gasketed — Area — Fluorescent
Starting and Operating Amps
Lighting
Type of Ballast
26 Watt PL-T Fluorescent
120
277
347
32 Watt PL-T Fluorescent
120
277
347
42 Watt PL-T Fluorescent
120
277
347
52 Watt PL-T Fluorescent
120
277
347
57 Watt PL-T Fluorescent V
120
277
347
64 Watt PL-T Fluorescent
120
277
347
84 Watt PL-T Fluorescent
120
277
347
114 Watt PL-T Fluorescent V
120
277
347
Fuse catalog number: MLF2 (1 required for 120 V or 277 V) – 2-Amp fuse, time delay.
Minimum starting temperature: 0 °F/-18 °C
Energy Efficiency and Lamp Life Comparison
Lamp Type
Watts
Lumens
Lumen Output Comparison
Rated Average
Life (Hours)
Incandescent
100
1750
750
Incandescent
150
2880
750
Incandescent
200 (PS-25, PS-30)
3710
750
Incandescent
200 (A-23)
4010
750
PL-T Fluorescent
26
1800
10,000
PL-T Fluorescent
32
2400
10,000
PL-T Fluorescent
42
3200
10,000
PL-T Fluorescent
52
3600
10,000
PL-T Fluorescent
57 V
4300
12,000
PL-T Fluorescent
64
4800
10,000
PL-T Fluorescent
84
6400
10,000
PL-T Fluorescent
114 V
8600
12,000
V CSA Certification only.
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
Light Output as Function of Temperature
Relative
Light
Output %
PL-T
(Amalgam)
Quad --Degrees F
High lumen output of the amalgam technology lamp vs. the
reduced light output at variable temperatures from a typical
compact fluorescent lamp.
1065
Mercmaster™ III Low Profile Compact Fluorescent Luminaire Dimensions
Enclosed and Gasketed. For Hazardous and Wet Locations
Compact Fluorescent listed for simultaneous exposure to combustible dusts and flammable gases or vapors.
Dimensions
Pendant
12.06"/
306.3 mm
Pendant Cone
1.17"/
29.7 mm
Ceiling
25 Stanchion
13.62"/
346.9 mm
12.06"/
306.3 mm
12.06"/
306.3 mm
/
27”
15. .9 mm
387
5.59"/
142.0 mm
0”/
2.0 mm
8
50.
5”/
9.2 0 mm
5.
23
1.75"/
44.5 mm
/
03”
12. .6 mm
305
Wall Mount
17.00"/
431.8 mm
t
Se w
re
Sc
10.93”/
277.6 mm
25°
12.03”/
305.6 mm
9”/
7.5 8 mm
.
192
Polyester Reflector
17.23”/
437.6 mm
5.90"/
149.9 mm
9.79”/
248.7 mm
Globe or Polymeric
Refractor Ballast Housing
8" Glass Refractor
Ballast Housing
13.38"/
339.9 mm
13.38"/
339.9 mm
12.03”/
305.6 mm
Lighting
3.04"/
77.2 mm
5.50"/
139.7 mm
11.12"/
282.4 mm
18.70"/
475.0 mm
3.04"/
77.2 mm
2.48"/
63.0 mm
10.17"/
258.3 mm
"/
.06 m
17 .3 m
3
43
7.75"/
196.9 mm
11.12"/
282.4 mm
Globe and Refractors
5.50"/
139.7 mm
Lighting: Enclosed and Gasketed — Area — Fluorescent
5.50"/
139.7 mm
8.00"/
203.2 mm
4.50"/
114.3 mm
Aluminum Guards
7.94"/
201.6 mm
7.75"/
196.9 mm
7.25"/
184.2 mm
10.75"/
237.1 mm
12.38"/
314.5 mm
2.75"/
69.9 mm
6.75"/
171.5mm
11.00"/
279.4 mm
8.50"/
215.9 mm
5.88"/
149.4 mm
7.50"/
190.5 mm
8.88"/
225.6 mm
Accessory Weights ➊
Ballast Housings and
Mounting Hoods
Pendant
Pendant Cone
Ceiling
Wall Mount
25° Stanchion
90° Stanchion
Globe/Polymeric Refractor Housing
Glass Refractor Housing
Wt. Lbs/Kgs
2.25/1.0
2.50/1.1
3.00/1.4
4.00/1.8
3.25/1.5
3.75/1.7
5.60/2.5
6.50/2.9
Refractors, Globe,
Guards and Reflectors
8” Glass Refractor
Glass Globe
Glass Globe — 57/114 W V
Polymeric Refractor ➋
Glass Refractor Guard
Globe Guard
Globe Guard — 57/114 W V
Standard Dome
30° Angle
Exit Sign ➋
Wt. Lbs/Kgs
5.25/2.4
3.75/1.7
8.35/ 3.8
2.43/1.1
1.00/0.5
1.00/0.5
2.00/0.9
2.50/1.1
2.50/1.1
5.00/2.3
➊ Weights are approximate.
➋ Not listed for Class I, Zone 2 areas.
V CSA Certification only.
1066
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
EFDB™ Series Factory-Sealed Photocontrol
Explosionproof, Dust-Ignitionproof
For use with Threaded Metal Conduit.
Explosionproof Remote
Photocontrol – Single Gang
Class I, Groups B, C, D
Class II, Groups, E, F, G
Class III
Applications
• Factory-sealed control stations
confine arcing of device within
the enclosure, preventing ignition
of atmospheres.
• Used in classified areas where
flammable vapors, gases or highly
combustible dusts are present.
• For installation in chemical and
petrochemical plants, refineries and
other process industries, or where
corrosive elements are present.
Features
Voltage
Max
Current (A)
Max
VA
1/2
120
8.3
1000
EFDB150PC120
EFDCB150PC120
3/4
120
8.3
1000
EFDB175PC120
EFDCB175PC120
1
120
8.3
1000
EFDB110PC120
EFDCB110PC120
Replacement Parts for Remote Photocontrol
Catalog Number
Complete Cover
Photocontrol
Assembly
Only
Voltage
Current (A)
Max
VA
120
8.3
1000
EFKB-PC120
PC120X
208-277
3.5
1000
EFKB-PC277
PC277X
EFDB Single Gang
5/16 Dia. (2) Mtg. Holes
12-24 x 1
(4) Screws
A
B
4.63”/
117.6 mm
Lighting
• Finish is an epoxy powder coat for
enhanced corrosion resistance.
• Corrosion-resistant stainless steel
hex-head captive screws hold cover
to body.
• Factory-sealed enclosure eliminates
need for adding sealing fittings and
compound at each conduit entrance
(for Groups C & D applications).
• Accurately tapped, tapered
hubs for tight, rigid joints and
ground continuity.
• Smooth, rounded integral
bushing in each hub protects
conductor insulation.
Catalog Number ➋
Dead End
Feed Through
Hub Size
(Inches)
5.41”/
137.4 mm
Lighting: Enclosed and Gasketed — Area — Fluorescent
C
2.31”/
58.7 mm
3.00”/
76.2 mm
4.81”/
122.2 mm
Dimensions in Inches
B
Hub Size
(Inches)
A
1/2 & 3/4
5.38
6.13
.78
1
5.50
6.31
.94
C
Turn On 1 to 3 footcandles; Turn On/Turn Off ratio: 1:3, Temperature range: -30 °F through 140 °F.
For Class I, Group B, external seals must be installed at each conduit entrance.
For 208-277 volt rating, change 120 suffix to 277; current ratings become 3.5 A.
➋ Standard catalog number represents malleable iron body with aluminum cover. For aluminum body, add suffix -A.
V CSA Certification only.
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
1067
Mercmaster™ III Low Profile Compact Fluorescent Luminaire Photometric Data
Enclosed and Gasketed. For Hazardous and Wet Locations
Compact Fluorescent listed for simultaneous exposure to combustible dusts and flammable gases or vapors.
* Photometric data is based on a fixture with
a 32 W compact fluorescent PL-T lamp (2,400
lumens).
Lighting: Enclosed and Gasketed — Area — Fluorescent
Lighting
Zone
Lumens
0-10
10.23
10-20
34.38
Total Luminaire Efficiency = 86.1%
CIE Type – Semi-Direct
Spacing
Criteria
Plane
20-30
64.27
30-40
105.64
0-180
2.80
40-50
151.34
90-270
2.68
50-60
194.61
Diagonal
2.50
60-70
224.08
70-80
243.06
80-90
248.58
90-100
100-110
110-120
120-130
130-140
140-150
150-160
160-170
170-180
241.28
220.55
182.81
109.74
33.74
1.67
0.14
0.00
0.00
Zone
Lumens
Zonal Lumen Summary
Zone
0-30
0-40
0-60
0-90
90-120
90-130
90-150
90-180
180-0
Lumens % Lamp % Fixture
108.88
4.5
5.3
214.52
8.9
10.4
560.47 23.4
27.1
1276.18 53.2
61.8
644.64 26.9
31.2
754.38 31.4
36.5
789.80 32.9
36.5
789.94 32.9
38.2
2066.12 86.1
100.0
10-20
105.58
20-30
178.09
30-40
242.36
0-180
1.68
40-50
291.93
90-270
1.64
50-60
323.02
Diagonal
1.74
60-70
314.54
70-80
216.11
80-90
76.59
Zone
Lumens
CIE Type – Direct
Spacing
Criteria
Plane
Zonal Lumen Summary
Zone
0-30
0-40
0-60
0-90
90-120
90-130
90-150
90-180
180-0
Lumens % Lamp % Fixture
318.12 13.3
17.8
560.48 23.4
31.4
1175.44 49.0
65.8
1782.68 74.3
99.8
3.72
0.2
0.2
3.72
0.2
0.2
3.72
0.2
0.2
3.72
0.2
0.2
1786.40 74.4
100.0
10-20
86.63
20-30
147.04
30-40
206.00
0-180
2.20
40-50
241.56
90-270
1.76
50-60
246.42
Diagonal
1.72
60-70
226.09
70-80
191.43
80-90
143.57
1068
80
70
50
30
10
0
0 95 95 95 95 89 89 89 89 77 77 77 67 67 67 58 58 58 53
1 81 75 70 65 75 70 65 61 60 56 53 51 48 45 43 40 38 34
2
3
4
5
6
7
8
9
10
72
64
58
53
48
45
41
38
36
63
53
46
41
36
32
29
26
24
55
45
38
32
28
24
21
19
17
49
38
31
26
22
18
16
14
12
66
59
53
49
44
41
38
35
33
58
49
43
38
33
30
27
24
22
51
42
35
30
26
22
20
18
16
46
36
29
24
20
17
15
13
11
50
42
36
32
28
25
23
21
19
44
36
30
26
22
19
17
15
14
40
31
25
21
17
15
13
11
10
42
35
30
27
24
21
19
18
16
37
30
25
21
19
16
14
13
12
34
26
21
17
15
12
11
9
8
34
29
25
22
19
18
16
15
13
31
25
21
18
15
13
12
11
10
28
22
17
14
12
10
9
8
7
24
18
14
11
9
8
7
6
5
REPORT NUMBER: MLF32ST
Lamps: One 32 W lamp with Standard Dome Reflector *
Coefficients of Utilization - Zonal Cavity Method
Effective Floor Cavity Reflectance 0.20
% Ceiling Rcc
80
70
50
30
10
0
0 89 89 89 89 86 86 86 86 83 83 83 79 79 79 76 76 76 74
1 79 75 71 67 77 73 69 66 70 67 64 66 64 62 64 62 60 58
2
3
4
5
6
7
8
9
10
70
63
57
52
48
44
41
38
36
63
54
47
41
37
33
30
27
25
57
47
40
34
29
26
23
21
19
52
41
34
28
24
21
18
16
14
68
61
55
50
46
43
40
37
35
62
53
46
40
36
32
29
27
25
56
46
39
33
29
26
23
20
18
51
41
34
28
24
21
18
16
14
59
50
44
39
35
31
28
26
24
54
45
38
33
28
25
22
20
18
50
40
33
28
24
21
18
16
14
56
48
42
37
33
30
27
25
23
52
43
37
32
28
24
22
20
18
49
39
33
27
23
20
18
16
14
54
46
40
36
32
29
26
24
22
51
42
36
31
27
24
21
19
18
48
39
32
27
23
20
18
16
14
46
37
30
25
21
19
16
14
13
Total Luminaire Efficiency = 68.5%
27.92
85.71
34.86
6.37
0.80
0.00
0.00
0.00
0.00
0.00
Effective Floor Cavity Reflectance 0.20
% Ceiling Rcc
% Walls Rw 70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0
0-10
90-100
100-110
110-120
120-130
130-140
140-150
150-160
160-170
170-180
Coefficients of Utilization - Zonal Cavity Method
Total Luminaire Efficiency = 74.4%
34.45
3.47
0.25
0.00
0.00
0.00
0.00
0.00
0.00
0.00
REPORT NUMBER: MLF32G
Lamps: One 32 W lamp with Globe only *
% Walls Rw 70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0
0-10
90-100
100-110
110-120
120-130
130-140
140-150
150-160
160-170
170-180
For candlepower values of fixtures with a 26
W PL-T lamp (1,800 lumens), multiply by 0.75.
For candlepower values of fixtures with a 42 W
PL-T lamp (3,200 lumens), multiply by 1.34.
CIE Type – Direct
Spacing
Criteria
Plane
REPORT NUMBER: MLF32AN
Lamps: One 32 W lamp with 30° Angle Dome Reflector *
Coefficients of Utilization - Zonal Cavity Method
Effective Floor Cavity Reflectance 0.20
% Ceiling Rcc
80
70
50
30
10
0
% Walls Rw 70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0
Zonal Lumen Summary
Zone
0-30
0-40
0-60
0-90
90-120
90-130
90-150
90-180
180-0
Lumens % Lamp % Fixture
261.58 10.9
15.9
467.59 19.5
28.4
955.56 39.8
58.1
1516.66 63.2
92.2
126.94
5.3
7.7
127.74
5.3
7.8
127.74
5.3
7.8
127.74
5.3
7.8
1644.40 68.5
100.0
0 80 80 80 80 78 78 78 78 73 73 73 69 69 69 65 65 65 63
1 71 66 62 59 68 64 60 57 60 57 54 56 54 52 53 51 49 47
2
3
4
5
6
7
8
9
10
63
57
51
47
43
40
37
34
32
56
48
42
37
33
30
27
25
22
50
42
35
30
26
23
21
18
17
45
36
30
25
21
19
16
14
13
61
54
49
45
41
38
35
33
31
54
47
41
36
32
29
26
24
22
49
41
34
30
26
23
20
18
16
44
36
29
25
21
18
16
14
13
51
44
38
34
30
27
25
23
21
46
39
33
28
25
22
19
17
16
43
34
28
24
20
18
16
14
12
48
41
36
32
29
26
23
22
20
44
37
31
27
24
21
19
17
15
41
33
27
23
20
17
15
14
12
45
39
34
30
27
24
22
20
19
42
35
30
26
23
20
18
16
15
39
32
26
22
19
17
15
13
12
37
30
25
21
18
15
13
12
10
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
Mercmaster™ III Low Profile Compact Fluorescent Luminaire Photometric Data
Enclosed and Gasketed. For Hazardous and Wet Locations
Compact Fluorescent listed for simultaneous exposure to combustible dusts and flammable gases or vapors.
* Photometric data is based on a fixture with
a 32 W compact fluorescent PL-T lamp (2,400
lumens).
Zone
Lumens
Total Luminaire Efficiency = 80.9%
0-10
18.85
10-20
63.99
20-30
125.20
30-40
205.98
0-180
2.24
40-50
294.73
90-270
2.64
50-60
370.74
Diagonal
2.74
60-70
425.25
70-80
457.39
80-90
90-100
100-110
110-120
120-130
130-140
140-150
150-160
160-170
170-180
463.07
445.19
402.45
328.71
203.51
69.29
8.05
0.13
0.00
0.00
Zone
Lumens
CIE Type – Semi-Direct
Spacing
Criteria
Plane
Zonal Lumen Summary
Zone
0-30
0-40
0-60
0-90
90-120
90-130
90-150
90-180
180-0
Lumens % Lamp % Fixture
208.05
4.3
5.4
414.02
8.6
10.7
1079.50 22.5
27.8
2425.21 50.5
62.5
1176.35 24.5
30.3
1379.86 28.7
35.5
1457.21 30.4
35.5
1457.34 30.4
37.5
3882.55 80.9
100.0
193.68
20-30
332.52
30-40
456.54
0-180
1.62
40-50
551.40
90-270
1.66
50-60
602.56
Diagonal
1.84
60-70
573.69
70-80
386.39
CIE Type – Direct
Spacing
Criteria
Plane
80
70
50
30
10
0
0 89 89 89 89 83 83 83 83 73 73 73 63 63 63 55 55 55 51
1
2
3
4
5
6
7
8
9
10
76
68
61
55
50
46
42
39
36
34
71
59
50
44
38
34
30
27
25
22
66
52
42
35
30
26
23
20
18
16
61
46
36
29
24
20
17
15
13
11
71
62
56
50
46
42
39
36
33
31
66
55
47
40
35
31
28
25
23
21
61
48
40
33
28
24
21
19
17
15
57
43
34
27
23
19
16
14
12
11
57
47
40
34
30
27
24
22
20
18
53
42
34
28
24
21
18
16
14
13
50
37
29
24
19
16
14
12
11
9
48
40
33
29
25
23
20
18
17
15
45
36
29
24
20
18
15
14
12
11
43
32
25
20
17
14
12
10
9
8
41
33
28
24
21
19
17
15
14
13
38
30
24
20
17
15
13
11
10
9
36
27
21
17
14
11
10
8
7
6
32
23
18
14
11
9
8
6
5
5
REPORT NUMBER: MLF64ST
Lamps: Two 32 W lamps with Standard Dome Reflector *
Coefficients of Utilization - Zonal Cavity Method
Effective Floor Cavity Reflectance 0.20
% Ceiling Rcc
80
70
50
30
10
0
% Walls Rw 70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0
Zonal Lumen Summary
Lumens % Lamp % Fixture
589.15 12.3
17.9
1045.70 21.8
31.7
2199.66 45.8
66.7
3293.22 68.6
99.9
2.39
0.0
0.1
2.39
0.0
0.1
2.39
0.0
0.1
2.39
0.0
0.1
3295.61 68.7
100.0
0 82 82 82 82 80 80 80 80 76 76 76 73 73 73 70 70 70 69
1
2
3
4
5
6
7
8
9
10
73
65
59
53
48
44
41
38
35
33
69
58
50
44
38
34
31
28
25
23
65
53
44
37
31
27
24
21
19
17
62
48
38
31
26
22
19
17
15
13
71
63
57
51
47
43
40
37
34
32
67
57
49
43
38
33
30
27
25
23
64
52
43
36
31
27
24
21
19
17
61
48
38
31
26
22
19
17
15
13
64
55
47
41
36
32
29
26
24
22
62
50
42
35
30
26
23
21
19
17
59
46
37
31
26
22
19
17
15
13
62
52
45
39
35
31
28
25
23
21
59
49
40
34
29
26
23
20
18
17
57
45
37
30
25
22
19
17
15
13
59
50
43
38
33
30
27
24
22
21
57
47
39
33
29
25
22
20
18
16
56
44
36
30
25
22
19
16
15
13
54
43
34
28
24
20
17
15
13
12
Total Luminaire Efficiency = 62.8%
50.16
10-20
156.40
20-30
272.40
30-40
383.54
0-180
2.16
40-50
446.01
90-270
1.70
50-60
442.26
Diagonal
1.80
60-70
405.74
70-80
352.81
CIE Type – Direct
Spacing
Criteria
Plane
REPORT NUMBER: MLF64AN
Lamps: Two 32 W lamps with 30° Angle Dome Reflector *
Coefficients of Utilization - Zonal Cavity Method
Effective Floor Cavity Reflectance 0.20
% Ceiling Rcc
80
70
50
30
10
0
% Walls Rw 70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0
Zonal Lumen Summary
Zone
0-30
0-40
0-60
0-90
90-120
90-130
90-150
90-180
180-0
Lumens % Lamp % Fixture
478.96 10.0
15.9
862.50 18.0
28.6
1750.77 36.5
58.1
2778.65 37.9
92.2
234.15
4.9
7.8
235.69
4.9
7.8
235.69
4.9
7.8
235.69
4.9
7.8
3014.34 62.8
100.0
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
0 74 74 74 74 71 71 71 71 67 67 67 63 63 63 60 60 60 58
1
2
3
4
5
6
7
8
9
10
65
58
52
47
43
40
36
34
31
29
61
51
44
39
34
30
27
25
22
21
57
46
38
32
28
24
21
19
17
15
54
42
33
27
23
20
17
15
13
12
62
55
50
45
41
38
35
32
30
28
59
50
43
37
33
29
26
24
22
20
55
45
37
31
27
24
21
19
17
15
52
41
33
27
23
19
17
15
13
12
55
46
40
35
31
28
25
23
21
19
52
42
35
30
26
23
20
18
16
15
50
39
31
26
22
19
16
14
13
11
52
44
38
33
29
26
24
22
20
18
49
40
34
29
25
22
19
17
15
14
47
37
30
25
21
18
16
14
12
11
48
41
35
31
27
25
22
20
19
17
47
38
32
27
24
21
18
16
15
14
45
36
29
24
21
18
15
14
12
11
43
34
27
22
19
16
14
12
11
10
1069
Lighting: Enclosed and Gasketed — Area — Fluorescent
Zone
0-30
0-40
0-60
0-90
90-120
90-130
90-150
90-180
180-0
0-10
80-90
269.34
90-100 159.49
100-110 63.13
110-120 11.54
120-130
1.54
130-140
0.00
140-150
0.00
150-160
0.00
160-170
0.00
170-180
0.00
Effective Floor Cavity Reflectance 0.20
% Ceiling Rcc
Lighting
10-20
Lumens
Coefficients of Utilization - Zonal Cavity Method
Total Luminaire Efficiency = 68.7%
62.95
Zone
REPORT NUMBER: MLF64G
Lamps: Two 32 W lamps with Globe only *
% Walls Rw 70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0
0-10
80-90
133.48
90-100
2.39
100-110
0.00
110-120
0.00
120-130
0.00
130-140
0.00
140-150
0.00
150-160
0.00
160-170
0.00
170-180
0.00
For candlepower values of fixtures with a 26
W PL-T lamp (1,800 lumens), multiply by 0.75.
For candlepower values of fixtures with a 42 W
PL-T lamp (3,200 lumens), multiply by 1.34.
FV™ Series Nonmetallic Fluorescent Luminaires
For Hazardous and Adverse Locations
Class I, Division 2, Groups A, B, C, D
Class I, Zone 2, Group IIC
Class II Division 1, Groups E, F, G
Class II, Division 2, Groups F, G
Marine Type Electric Fixture
Outside Type (Salt Water) *
Type 4X
Wet Locations
Applications
• For use in hazardous locations defined by the NEC as Class I,
Division 2, Groups A, B, C and D; Class II, Division 2, Groups
F and G; Marine Outdoor Salt Water; UL1598A; Type 4X; and
Class I, Zone 2 II C.
• For use in locations where a high degree of corrosion resistance
is required.
• For indoor or outdoor use where protection against dirt, water
and moisture is necessary.
• Typical applications include oil refineries, petrochemical
facilities, pulp and paper mills, food processing plants,
warehouses, underground tunnels and general manufacturing
facilities.
Lighting
Features
• Stainless steel hubs (3/4”) provided as standard.
• Ballast options for nearly all U.S. and foreign voltage and
frequency combinations are available.
• Low operating costs provide more lumens per Watt than
incandescent fixtures.
• Impact-resistant polycarbonate lens is hinged to allow easy
access to lamp compartment.
• Corrosion-resistant fiberglass reinforced polyester housing.
• Actuator allows access to lamps and ballast compartment –
no tools required.
• Latch assembly and elastomer type gasket provide positive
seal from water ingress.
• Safety switch (supplied as standard) disconnects power to
lamps and ballast when lens is open.
• Reflector is hinged for easy single-handed entry to ballast
compartment.
• Actuator can be removed for tamper-resistant applications.
Compliancies and Certifications
• UL Standard: UL 1598, UL 844, UL 60079-0, UL 60079-15
• UL Listed: E10794
• CSA Standard: C22.2 No. 250, C22. 2 No. 137, CAN E60079-0,
CAN E60079-15
• cUL Listed: E10794
Lighting: Enclosed and Gasketed — Area — Fluorescent
Standard Materials
•
•
•
•
•
•
•
•
Housing: fiberglass reinforced polyester
Lens: polycarbonate
Gasket: elastomer
Hubs: stainless steel
Lampholders: polycarbonate
Internal reflector: highly reflective white polycarbonate
Fixed surface mount: (2) 14-gauge stainless steel
Adjustable wall mount: (2) copperfree (4/10 of 1% max.)
aluminum
• 45° fixed wall mount: (2) 11-gauge (1/8”) stainless steel
• Chain ring bolt: set of 2 zinc plated steel (internal diameter .78”)
Options
•
•
•
•
Individually fused ballast. Add suffix -F.
Terminal block. Add suffix -T.
Emergency battery pack. Add suffix -EL.
Emergency light capability in moments of power interruption.
Luminaire automatically switches to emergency mode, keeping
one lamp illuminated for a minimum of 90 minutes. When AC
power is restored, battery automatically recharges in 24 hours.
Initial light output is 600-700 lumens.
* Does not apply to fixtures with fusing.
1070
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
FV™ Series Nonmetallic Fluorescent Luminaires
For Hazardous and Adverse Locations
Class I, Division 2, Groups A, B, C, D
Class I, Zone 2, Group IIC
Class II Division 1, Groups E, F, G
Class II, Division 2, Groups F, G
Marine Type Electric Fixture
Outside Type (Salt Water) *
Type 4X
Wet Locations
Order using catalog numbering guide below or select catalog number from tables on following pages.
Catalog Numbering Guide For FV Series Nonmetallic Fluorescent Luminaires
FV
Series:
FV - FV Series
P
2
32
Number of Lamps:
2 - 2 Lamps
3 - 3 Lamps (32 W only)
4 - 4 Lamps (40 W only,
F40BX)
Lamp Type:
P - "PL" Fluorescent (F40BX)
R - Rapid Start
H - High Output
BU
SO
Voltage ①:
347 - 347 V 60 Hz V
BU - 120-277 V 50/60 Hz ③
Wattage:
32 - 32 W (T8)
40 - 40 W (T12-RS, F40BX)
44 - 44 W (T-8-HO)
60 - 60 W (T-12-HO)
F
Options:
F - Fuse
T - Terminal Block (6 Point)
EL - Emergency Battery Pack ②
Ballast Type:
SS - Solid State (for 347 V T-12)
Lamp
Type
Hub Size
(Inches)
Overall Fixture Length
(Inches/Millimeters)
Volts
2
40
F40BX
3/4
31/787.4
120-277
2
40
F40BX
3/4
31/787.4
347
4
40
F40BX
3/4
55/1397
120-277
4
40
F40BX
3/4
55/1397
347
2
32
T8
3/4
55/1397
120-277
2
32
T8
3/4
55/1397
347
2
44
T8-HO
3/4
55/1397
120-277
2
44
T8-HO
3/4
55/1397
347
2
40
T12
3/4
55/1397
120-277
2
40
T12
3/4
55/1397
347
2
60
T12-HO
3/4
55/1397
120-277
2
60
T12-HO
3/4
55/1397
347
3
32
T8
3/4
55/1397
120-277
3
32
T8
3/4
55/1397
347
Catalog
Number ⑦
FVP240BU
FVP240-347 V
FVP440BU
FVP440-347 V
FVR232BU
FVR232-347S0 V
FVH244BU
FVH244-347S0 V
FVR240BU
FVR240-347SS V
FVH260BU
FVH260-347SS V
FVR332BU
FVR332-347S0 V
Note: BU ballasts are auto-sensing, solid state for any voltage between 120 and 277 V, 50 or 60 Hz.
* Does not apply to fixtures with fusing.
① Consult factory for availability of specific voltages.
② 4’ fixture only.
③ 32 W SS Octron and F40BX only.
V CSA Certification only.
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
1071
Lighting: Enclosed and Gasketed — Area — Fluorescent
Lamp
Watts
Lighting
Number of
Lamps ⑥
FV™ Series Nonmetallic Fluorescent Luminaires
For Hazardous and Adverse Locations
Class I, Division 2, Groups A, B, C, D
Class I, Zone 2, Group IIC
Class II Division 1, Groups E, F, G
Class II, Division 2, Groups F, G
Marine Type Electric Fixture
Outside Type (Salt Water) *
Type 4X
Wet Locations
Description
Catalog
Number
Standard Materials
14-gauge stainless steel
FVSM
Adjustable Wall Mount (set of 2)
Copperfree (4/10 of 1% max.) aluminum
FVWAM
Fixed 45°˚ Wall Mount (set of 2)
11-gauge (1/8”) stainless steel
FVWFM
Chain Mount (set of 2)
Zinc plated steel M8 ring bolts (chain not provided)
FVCM
Lighting
Surface Mount (set of 2)
Technical Data — Thermal Performance of FV Series Fixtures
For supply connection, use wire rated 167 °F/75 °C.
Lighting: Enclosed and Gasketed — Area — Fluorescent
Lamp
Min. Start
Temp ˚
(°C/°˚F)
Ambient
Temp.
(°C/°˚F)
“T”
Numbers
Quantity
Watt
Type
Lamp
Lumens
FVP240BU
2
40
F40BX
3300
-18/0
55/131
T4
FVP240-347 V
2
40
F40BX
3300
-18/0
55/131
T4
FVP440BU
4
40
F40BX
3300
-18/0
55/131
T4
FVP440-347 V
4
40
F40BX
3300
-18/0
55/131
T4
FVR232BU
2
32
T8-RS
2850
-18/0
40/104
T6
FVR232-347S0
2
32
T8-RS
2850
-18/0
40/104
T6
FVH244-BU
2
44
T8-HO
4050
-10/14
40/104
T6
FVH244-347S0 V
2
44
T8-HO
4050
-10/14
40/104
T6
FVR240BU
2
40
T12-RS
3050
10/50
40/104
T5
FVR240-347SS V
2
40
T12-HO
3050
10/50
40/104
T5
FVH260BU
2
60
T12-HO
4050
-28/-20
40/104
T4A
FVH260-347SS V
2
60
T12-HO
4050
-28/-20
40/104
T4A
FVR332BU
3
32
T8-RS
2850
-18/0
40/104
T6
Fixture
* Does not apply to fixtures with fusing.
V CSA Certification only.
1072
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
FV™ Series Nonmetallic Fluorescent Luminaire Dimensions
For Hazardous and Adverse Locations
Dimensions
FV Series
A
0.6"/
15.24 mm
5.7"/
144.8 mm
8.6"/
218.4
mm
B
FVWFM
FVWAM
FVSM
FVCM
Ø 0.31"/
8.0 mm
Ø 0.78"/
19.8 mm
9.25”/
235.0 mm
0.31"/
7.87 mm
60° MAX.
0.20"/
5.08 mm
1.25"/
31.8 mm
0.20"/
5.08 mm
4.00”/
101.6 mm
3.56"/
90.4 mm
7.72"/
196.1 mm
0.31"/
7.87 mm
0.38”/
9.5 mm
Lighting: Enclosed and Gasketed — Area — Fluorescent
0.31"/
7.9 mm
Dia.
0.31"/
7.87 mm
25 1.0
.4 0"
m /
m
7.64"/
194.1 mm
Ø 0.31"/8.0 mm
Lighting
7.5”/
190.5 mm
9.5"/
241.3 mm
0.59"/
15.0 mm
10 4.
4. 13
9 "/
m
m
9.21”/
233.9 mm
60 2.3
.5 8"
m /
m
8
20 .
2
9. 5
6 "/
m
m
24 9.
1. 50
3 "/
m
m
23 0.9
.9 4"
m /
m
0.70"/
17.78 mm
0.25"/
6.3 mm Dia.
Mounting Centers and Overall Length
A
B
2 FT./0.6 M
15.80”/401.3 mm
31.00”/787.4 mm
4 FT./1.2 M
27.60"/701.0 mm
55.00”/1397.0 mm
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
1073
FV™ Series Nonmetallic Fluorescent Luminaire Photometric Data
For Hazardous and Adverse Locations
Lighting: Enclosed and Gasketed — Area — Fluorescent
Lighting
CIE TYPE – DIRECT
PLANE: 0 DEG. 90 DEG.
SPACING CRITERIA:
1.2
1.5
CANDELA DISTRIBUTION
0
5
15
25
35
45
55
65
75
85
90
0.0
3152
3139
3030
2798
2470
2043
1523
941
378
49
10
45.0
3152
3138
3060
2910
2740
2517
2130
1656
1234
679
474
ZONAL
90.0 LUMENS
3152
3130
299
3036
868
3041 1351
2091 1720
2760 1897
2373 1827
1976 1553
1532 1163
901
649
694
CIE TYPE – DIRECT
PLANE: 0 DEG. 90 DEG.
SPACING CRITERIA:
1.2
1.5
CANDELA DISTRIBUTION
0
5
15
25
35
45
55
65
75
85
90
0.0
1101
1098
1056
976
856
710
528
328
132
14
4
45.0
1101
1098
1069
1026
985
928
830
681
567
340
252
ZONAL
90.0 LUMENS
1101
1097
104
1085
303
1093
477
1096
616
1075
703
986
709
849
636
757
530
499
332
397
CIE TYPE – DIRECT
PLANE: 0 DEG. 90 DEG.
SPACING CRITERIA:
1.2
1.4
CANDELA DISTRIBUTION
0
5
15
25
35
45
55
65
75
85
90
0.0
1780
1767
1700
1574
1388
1150
860
53
214
21
7
1074
45.0
1780
1773
1732
1661
1554
1388
12001
6949
698
443
319
ZONAL
90.0 LUMENS
1780 169
1771 169
1757 490
1734 767
1652 1064
1556 1064
3671 038
1116 881
914 675
637 426
491
50
.95
.80
.69
.60
.53
.47
.43
.39
.36
.33
.30
10
30
.95
.78
.65
.55
.48
.42
.37
.33
.30
.27
.24
10
.95
.75
.61
.51
.43
.37
.32
.28
.25
.23
.20
FVP 440, Four 40 W PL Lamps • Total Luminaire Efficiency = 85.8%
% Floors Rfc
20
% Ceiling Rcc
80
70
50
30
% Walls Rw 70 50 30 10 70 50 30 10
50 30 10
50 30 10
0 1.02 1.02 1.02 1.02 1.00 1.00 1.00 1.00 .95 .95 .95 .91 .91 .91
1 .99 .93 .89 .84 .96 .91 .87 .83 .87 .83 .80 .83 .80 .78
2 .89 .80 .73 .67 .86 .78 .72 .66 .75 .69 .64 .72 .67 .63
3 .74 .64 .56 .50 .72 .63 .56 .50 .60 .54 .49 .58 .52 .48
4 .68 .56 .48 .42 .66 .55 .48 .42 .53 .46 .41 .51 .45 .40
5 .62 .50 .42 .36 .60 .49 .41 .35 .47 .40 .35 .46 .39 .35
6 .57 .45 .37 .31 .55 .44 .36 .31 .42 .36 .30 .41 .35 .30
7 .53 .41 .33 .27 .51 .40 .32 .27 .38 .32 .27 .37 .31 .26
8 .49 .37 .29 .24 .48 .36 .29 .24 .35 .28 .24 .34 .28 .24
9 .46 .34 .26 .21 .45 .33 .26 .21 .32 .26 .21 .31 .25 .21
10 .43 .31 .24 .19 .42 .31 .24 .19 .30 .23 .19 .29 .23 .19
50
.88
.80
.69
.55
.49
.44
.40
.36
.33
.30
.28
10
30
.88
.78
.65
.51
.44
.39
.34
.30
.27
.25
.23
0
10
0
.88 .86
.75 .73
.61 .59
.47 .45
.40 .38
.44 .32
.30 .28
.26 .24
.23 .22
.21 .19
.19 1.75
70
.92
.81
.73
.65
.60
.55
.50
.47
.43
.40
.38
FVR 232, Two T8 32 W Lamps* • Total Luminaire Efficiency = 77.4%
20
80
70
50
30
50 30 10 70 50 30 10
50 30 10
50 30 10
.92 .92 .92 .90 .90 .90 .90 .86 .86 .86 .82 .82 .82
.77 .72 .68 .79 .75 .71 .67 .71 .68 .65 .68 .66 .63
.65 .59 .53 .71 .64 .58 .53 .61 .56 .51 .58 .54 .50
.56 .49 .44 .63 .55 .49 .43 .53 .47 .43 .51 .46 .42
.49 .42 .36 .58 .48 .41 .35 .46 .40 .35 .44 .39 .34
.44 .37 .31 .53 .43 .36 .31 .41 .35 .31 .40 .34 .30
.39 .31 .26 .49 .38 .31 .26 .35 .30 .26 .35 .30 .25
.35 .28 .23 .45 .35 .28 .23 .33 .27 .22 .32 .26 .22
.32 .25 .20 .42 .31 .25 .20 .30 .24 .20 .29 .24 .20
.29 .22 .18 .39 .29 .22 .18 .28 .22 .18 .27 .21 .18
.27 .20 .16 .37 .26 .20 .16 .26 .20 .16 .25 .20 .16
50
.79
.65
.56
.49
.42
.38
.34
.31
.28
.26
.24
10
30
.79
.63
.52
.45
.38
.34
.29
.26
.23
.21
.19
10
.79
.61
.49
.41
.34
.30
.25
.22
.19
.17
.16
0
0
.77
.59
.47
.39
.32
.28
.23
.20
.18
.16
.14
70
.90
.80
.72
.65
.60
.55
.50
.46
.43
.40
.38
FVR 332, Three T8 32 W Lamps • Total Luminaire Efficiency = 75.7%
20
80
70
50
30
50 30 10 70 50 30 10
50 30 10
50 30 10
.90 .90 .90 .88 .88 .88 .88 .84 .84 .84 .81 .81 .81
.76 .72 .68 .78 .74 .70 .67 .71 .68 .65 .68 .65 .63
.65 .59 .54 .70 .63 .58 .53 .61 .56 .52 .58 .54 .51
.56 .49 .44 .63 .55 .49 .43 .53 .47 .43 .51 .46 .42
.50 .42 .37 .58 .48 .42 .36 .47 .41 .36 .45 .39 .35
.44 .37 .31 .53 .43 .36 .31 .41 .35 .31 .40 .34 .30
.39 .32 .27 .49 .39 .32 .27 .37 .31 .27 .36 .30 .26
.36 .29 .24 .45 .35 .28 .23 .34 .28 .23 .33 .27 .23
.32 .26 .21 .42 .32 .25 .21 .31 .25 .21 .30 .24 .21
.30 .23 .19 .39 .29 .23 .19 .28 .23 .19 .27 .22 .18
.27 .21 .17 .37 .27 .21 .17 .26 .21 .17 .25 .20 .17
50
.77
.65
.56
.49
.43
.38
.35
.32
.29
.27
.25
10
30
.77
.63
.52
.45
.38
.34
.30
.27
.24
.22
.20
10
.77
.61
.50
.41
.35
.30
.26
.23
.20
.18
.17
0
0
.76
.59
.48
.39
.33
.28
.24
.21
.19
.17
.15
Room Cavity Ratio
ZONAL
90.0 LUMENS
1705
1687
161
1688
468
1660
731
1623
932
1516 1027
1292
992
1065
836
821
619
497
351
399
Room Cavity Ratio
45.0
1705
1698
1642
1581
1492
1361
1161
888
644
360
257
• Total Luminaire Efficiency = 92.7%
20
50
30
10
50 30 10
50 30 10
1.08 1.03 1.03 1.03 .99 .99 .99
.83 .87 .83 .80 .83 .80 .78
.66 .75 .69 .64 .72 .67 .63
.54 .65 .58 .53 .62 .57 .52
.44 .57 .50 .44 .55 .49 .44
.38 .51 .44 .38 .49 .43 .37
.33 .46 .38 .33 .44 .38 .33
.29 .42 .34 .29 .40 .34 .29
.26 38 .31 .25 .37 .30 .25
.23 .35 .28 .23 .34 .27 .23
.21 .32 .25 .21 .31 .25 .21
% Floors Rfc
% Ceiling Rcc
% Walls Rw
0
1
2
3
4
5
6
7
8
9
10
Room Cavity Ratio
0
5
15
25
35
45
55
65
75
85
90
0.0
1705
1701
1635
1513
1324
1085
806
490
197
32
12
FVP 240, Two 40 W PL Lamps
% Floors Rfc
% Ceiling Rcc
80
70
% Walls Rw 70 50 30 10 70 50 30
0 1.10 1.10 1.10 1.10 1.08 1.08 1.08
1 .99 .93 .89 .84 .96 .91 .87
2 .89 .80 .73 .67 .86 .78 .72
3 .80 .69 .61 .54 .78 .68 .60
4 .73 .61 .52 .45 .71 .60 .51
5 .67 .54 .45 .39 .65 .53 .45
6 .62 .49 .40 .33 .60 .48 .39
7 .57 .44 .35 .29 .55 .43 .35
8 .53 .40 .32 .26 .52 .39 .31
9 .50 .37 .29 .23 .48 .36 .28
10 .46 .34 .26 .21 .45 .33 .26
% Floors Rfc
% Ceiling Rcc
% Walls Rw
0
1
2
3
4
5
6
7
8
9
10
Room Cavity Ratio
CIE TYPE – DIRECT
PLANE: 0 DEG. 90 DEG.
SPACING CRITERIA:
1.2
1.5
CANDELA DISTRIBUTION
0
0
.93
.73
.59
.49
.41
.35
.30
.26
.23
.21
.19
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
FR™ Enclosed and Gasketed; FZ™ and FD™ Hazardous Locations Luminaires
Nonmetallic Fluorescent
4 foot, 2 lamp fixtures. High-impact fiberglass reinforced polyester fixtures suitable for use in wet and damp locations.
FR Series
Wet Locations
IP65 when used with optional polycarbonate
lens
FZ Series
Class I, Division 2, Groups A, B, C, D
Class I, Zone 2, IIC
AEx nA IIC T5 IP65
Ex nA IIC T5 IP65
FD Series
Class I, Division 2, Groups A, B, C, D
Class I, Zone 2, IIC
Applications
• For use in locations where a high degree of corrosion
resistance is required.
• FR Series:
— For use in areas where high humidity or water vapor are
present
— Typical uses include meat- or food-processing plants, dairy
or drug plants, breweries, kitchens, chemical plants, car
washes, laundries and parking garages.
— Can be used indoors or outdoors in protected locations
(wet locations).
— Operates safely in 100 °F/38 °C ambient temperature areas.
• FZ and FD Series:
— For use in hazardous locations defined by the NEC as
Class I, Division 2; and Class I, Zone 2.
— For wet-location use where protection against dirt, water
and moisture is necessary.
— Typical applications include oil refineries, petrochemical
facilities, pulp and paper mills, food-processing plants,
warehouses, underground tunnels and general
manufacturing facilities.
• FZ Series is UL Listed for Class I, Division 2 and Zone 2.
• FD Series fixture is UL listed for Class I, Division 2.
Features
• Housing: fiberglass reinforced polyester
• Lens: polycarbonate or acrylic. (Fixture has IP65 rating with
polycarbonate lens.) Acrylic lens supplied as standard
• Latches: celcon
• Ceiling mounting bracket: stainless steel
• Adjustable wall mount: copperfree (4/10 of 1% max.) aluminum
• Fixed wall mount: stainless steel
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
•
•
•
•
Chain mount: zinc plated steel
Gasket: non-thixotropic polyol
Hubs: zinc plated steel with neoprene o-ring
Lampholders: polycarbonate
Standard Finishes
• Housing: white color finish
• Celcon latches: white color finish
• Adjustable wall mount: epoxy powder coat
Options:
•
•
•
•
F - Fused
T - Terminal Blocks
P - Polycarbonate Lens for IP65 Rating
E - Emergency Battery Pack capability in moments of power
interruption. Luminiare automatically switches to emergency
mode, keeping one lamp illuminated for a minimum of 90
minutes. When AC power is restored, battery automatically
recharges in 24 hours. Initial light output is 600-700 lumens.
Compliancies and Certifications
•
•
•
FR Series:
— UL Standard: UL 1598
— UL Listed: E187946
— CSA Standard: C22.2 No. 250
— cUL Listed: E187946
FZ Series:
— UL Standard: UL 1598, UL 844, UL 60079-0, UL 60079-15
— UL Listed: E10794
— CSA Standard: C22.2 No. 250, C22.2 No. 137,
CAN E60079-0, CAN E60079-15
— cUL Listed: E10794
FD Series:
— UL Standard: UL 1598, UL 844
— UL Listed: E10794
— CSA Standard: C22.2 No. 250, C22.2 No. 137
— cUL Listed: E10794
1075
Lighting: Enclosed and Gasketed — Area — Fluorescent
Standard Materials
Non-thixotropic polyol gasket is
bonded to housing. With plastic
latches closed, it forms a continuous, tight seal with lens. Keeps out
moisture, vapor and dirt. Allows fast,
easy fixture washing.
Lighting
• Fixtures are available with ballasts to support T12 and T8
lamps for nearly all U.S. and foreign voltage and frequency
combinations.
• Low operating costs provide more lumens per Watt than
incandescent fixtures.
• Housing is smooth, seamless, one-piece injection molded.
• Lens comes in high-impact polycarbonate plastic or impactresistant acrylic.
• Fixtures are washable, non-conductive and corrosion-resistant.
• Enclosure is rated at IP65 (using polycarbonate lens), dust-proof
and protected against water spray.
• A compressible, one-piece, non-thixotropic polyol gasket
is bonded to the housing around the entire perimeter. It
forms a continuous tight seal with the lens to keep out dirt,
vapor and moisture.
• Lens is securely clamped to fixture using six captive
corrosion-proof molded celcon tension latches. Lens is
impact-resistant acrylic to protect lamps against breakage,
and protect work area from broken lamp glass.
• Electrical components are mounted on a metallic wireway.
Reflector is supported by internal safety springs to simplify
installation and servicing.
• Optional fusing protects circuitry against occasional line voltage
spikes.
• FR Series fixtures are available with one or two watertight 1/2”
hubs for electrical-feed mounting or single-entry mounting.
• FZ fixtures are available with either 1/2” NPT or cable gland
entries.
— Cable glands are not available with FD series.
Illustrated Features
FR™ Enclosed and Gasketed; FZ™ and FD™ Hazardous Locations Luminaires
Nonmetallic Fluorescent
4 foot, 2 lamp fixtures. High-impact fiberglass reinforced polyester fixtures suitable for use in wet and damp locations.
FR Series
Wet Locations
IP65 when used with optional polycarbonate
lens
FZ Series
Class I, Division 2, Groups A, B, C, D
Class I, Zone 2, IIC
AEx nA IIC T5 IP65
Ex nA IIC T5 IP65
FD Series
Class I, Division 2, Groups A, B, C, D
Class I, Zone 2, IIC
Order using catalog numbering guide below or select catalog number from tables on following pages.
Catalog Numbering Guide For FR, FZ And FD Nonmetallic Fluorescent Lighting Fixtures
FZ
N1
C
2
Conduit/Cable
Entry:
N1 - 1/2” NPT
Conduit Single
Entry
M1 - Cable Gland
Single Entry
⑤⑦
N2 - 1/2” NPT
Conduit (2 hubs
provided)
M2 - Cable Gland
Feed Thru ⑥⑦
Lighting
08
Number of Lamps:
2 - 2 Lamps
Series:
FR - Wet
Location
FZ - Zone 2,
AEx nA, Ex
nA
FD - Class I,
Division 2 ①
Lighting: Enclosed and Gasketed — Area — Fluorescent
4
Mounting
Configuration:
C - Ceiling
P - Pendant
S
126
Ballast Type:
S - Solid State ②
Lamp Length:
4 - 4 Feet
2
F
Number of Ballasts:
Blank - Single
2 - Double
Voltage:
347 - 347 V, 60 Hz V
BU - 120-277 V,
50/60 Hz
(0 °F/-18 °C
start)
Lamp Type:
08 - T8, 32 W, 265MA
12 - T12, 40 W, 430MA
Options:
F - Fused ⑧
T - Terminal Blocks ④
P - Polycarbonate
lens ③ for IP65
EL- Emergency
Battery Pack
① Fixture is not available with M1 or M2 cable entry options
② Cold weather standard for T8.
③ Use polycarbonate lens for IP65 rating. Polycarbonate lens is standard on FZ Series.
④ Standard equipment for FZ series
⑤ Fixture will be supplied with a 5’/1.5 m length of #14/3 cord and 3 prong plug (120 V) pre-installed when ordered with cable gland. Fixture with cable gland
can only be used with hook and chain mounting.
⑥ ???.
⑦ FZ Series fixtures are not UL Listed for Class I, Division 2 when used with cable glands. FZ Series fixtures are UL Classified for Class I, Zone 2 when used
with cable glands.
⑧ Canadian Electrical Code does NOT allow fusing in hazardous locations V.
V CSA Certification only.
1076
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
FR™ Enclosed and Gasketed; FZ™ and FD™ Hazardous Locations Luminaires
Nonmetallic Fluorescent. Accessories and Replacement Parts
4 foot, 2 lamp fixtures. High-impact fiberglass reinforced polyester fixtures suitable for use in wet and damp locations.
Item
Description
Catalog Number
Hub
1/2” NPT watertight conduit hub
FHUB
Cable gland
FGLAND
32 W (T8) and 40 W (T12) lampholder
FS0C40
Standard plastic clips
FPCLIP
Acrylic lens cover
FLENS
Polycarbonate lens cover ①
FPLENS
Cable Gland
Lampholder
Lens Clip
Lighting
Lens
Stainless steel bracket with mounting hardware (set of 2)
FBRACKET
11 gauge (1/8”) stainless steel (set of 2)
FVWFM
Lighting: Enclosed and Gasketed — Area — Fluorescent
Ceiling Mounting Bracket (Supplied standard with product)
Fixed 45° Wall Mount
① Polycarbonate lens standard for FZ series. When used with FD series, fixture has an IP65 rating.
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
1077
FR™ Enclosed and Gasketed; FZ™ and FD™ Hazardous Locations Luminaires
Nonmetallic Fluorescent. Dimensions
4 foot, 2 lamp fixtures. High-impact fiberglass reinforced polyester fixtures suitable for use in wet and damp locations.
38.75"/ 984.3 mm
6.50”/
165.1 mm
8.25”/209.6 mm
View of Fixture Cover
50.00”/ 1270 mm
Side View
Fixed 45° Wall Mount — FVWFM
7.44"/
7
-41/9
189.0
mm
4”
1.25"/
Lighting
7.72"/
196.1 mm
7-23/32”
1.50"/
38.1mm
3-9/16”
0.31"/
5/16”
7.9
mm
DIA.
Dia.
5.50"/
139.7 mm
3.56"/
90.4 mm
1-1/4”
31.8 mm
0.25"/
1/4”
6.35
mm
DIA.
Dia.
Lighting: Enclosed and Gasketed — Area — Fluorescent
3.25"/
82.6 mm
View of Fixture Mounting
1078
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
FR™ Enclosed and Gasketed; FZ™ and FD™ Hazardous Locations Luminaires
Nonmetallic Fluorescent. Photometric Data
4 foot, 2 lamp fixtures. High-impact fiberglass reinforced polyester fixtures suitable for use in wet and damp locations.
Candela Distribution
TOTAL LUMINAIRE EFFICIENCY = 84.6%
REPORT NUMBER: ITL 47240
0.0 22.5 45.0 67.5 90.0 Flux CIE Type – Semi-Direct
0 1155 1155 1155 1155 1155
0˚
Plane:
90˚
5 1159 1153 1150 1148 1148 110 Spacing Criteria: 1.3
Lamps: Two 32 W, 4-foot F32T8/TL735 fluorescents,
2850 lumens per lamp with acrylic lens.
1.5
15 1118 1118 1124 1134 1137 318 Shielding Angles: 1
0
25 1036 1049 1071 1109 1125 498
35
918 945 1010 1087 1114 636
45
766 812 927 1026 1056 710
55
569 652 788 900 927 690
65
342 450 598 719 753 574
75
148 259 432 567 604 434
85
25 133 318 444 473 312
COEFFICIENTS OF UTILIZATION - ZONAL CAVITY METHOD
EFFECTIVE FLOOR CAVITY REFLECTANCE 0.20
% Ceiling RC
80
70
50
30
10
0
90˚ % Walls RW 70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10
4
98 270 376 412
ZONAL LUMEN
SUMMARY
95
5
84 258 372 414 249
ZONE LUMENS
105
2
42 182 292 341 181
0- 30
115
0
13
69 139 182 79
0- 40 1562
125
0
3
22
36
50 21
0- 60 2962
135
0
0
9
15
19
7
0- 90 4282
145
0
0
2
7
9
2
90-120
509
155
0
0
0
0
2
0
90-130
529
165
0
0
0
0
0
0
90-150
538
175
0
0
0
0
0
0
90-180
539
180
0
0
0
0
0
75˚
0 .98 .98 .98 .98 .95 .95 .95 .95 .89 .89 .89 .83 .83 .83 .78 .78 .78 .75
1 .88 .83 .78 .74 .84 .80 .76 .72 .75 .71 .68 .70 .67 .65 .65 .63 .61 .58
400
60˚
926
2 .79 .71 .65 .59 .76 .69 .63 .58 .64 .59 .55 .60 .56 .52 .56 .52 .50 .47
3 .71 .62 .54 .48 .68 .60 .53 .47 .56 .50 .45 .52 .47 .43 .49 .45 .41 .39
800
45˚
4 .65 .54 .46 .40 .62 .52 .45 .39 .49 .43 .38 .46 .41 .36 .43 .38 .35 .32
5 .60 .48 .40 .34 .57 .47 .39 .33 .44 .37 .32 .41 .35 .31 .38 .34 .30 .28
6 .55 .43 .35 .29 .53 .52 .34 .29 .39 .33 .28 .37 .31 .27 .35 .30 .26 .24
1200
0˚
15˚
7 .51 .39 .31 .26 .49 .38 .30 .25 .36 .29 .24 .33 .28 .24 .32 .27 .23 .21
30˚
8 .47 .35 .28 .23 .45 .34 .27 .22 .32 .26 .22 .31 .25 .21 .29 .24 .20 .19
Legend
0-deg
45-deg
90-deg
9 .44 .32 .25 .20 .42 .31 .25 .20 .30 .24 .19 .28 .23 .19 .27 .22 .18 .17
10 .41 .30 .23 .18 .40 .29 .22 .18 .27 .22 .17 .26 .21 .17 .25 .20 .16 .15
0-180 4820
Candela Distribution
TOTAL LUMINAIRE EFFICIENCY = 83.6%
REPORT NUMBER: ITL 47241
0.0 22.5 45.0 67.5 90.0 Flux CIE Type – Semi-Direct
566 566 566 566 566
568 565 564 563 563 54 Spacing Criteria: 1.3
0˚
1.5
15
548 549 550 554 555 156 Shielding Angles: 1
0
25
506 512 523 543 552 243
35
448 461 495 535 549 312
45
374 396 458 509 525 350
55
283 324 399 457 475 349
65
177 241 318 393 409 306
75
72 142 211 259 267 210
Plane:
90˚
Lamps: Two 32 W, 4-foot F32T8/TL735 fluorescents,
2850 lumens per lamp with polycarbonate lens.
COEFFICIENTS OF UTILIZATION - ZONAL CAVITY METHOD
EFFECTIVE FLOOR CAVITY REFLECTANCE 0.20
90˚
85
6
63 150 212 228 146
90
1
46 118 167 186
ZONAL LUMEN
SUMMARY
95
1
43 122 176 198 118
ZONE LUMENS
105
0
20
115
0
125
75˚
190
60˚
% Ceiling RC
80
70
50
30
10
0
% Walls RW 70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10
0
0 .97 .97 .97 .97 .94 .94 .94 .94 .88 .88 .88 .82 .82 .82 .77 77 77 .75
1 .87 .82 .78 .74 .84 .79 .75 .72 .74 .71 .68 .69 .67 .64 .65 .63 .61 .58
84 131 154 83
0- 30
453
5
33
74
92 40
0- 40
765
2 .78 .70 .64 .58 .75 .68 .62 .57 .63 .59 .54 .59 .55 .52 .55 .52 .49 .47
0
1
10
18
24 10
0- 60 1464
135
0
0
5
9
10
4
0- 90 2126
145
0
0
1
4
5
1
90-120
241
155
0
0
0
1
1
0
90-130
251 Legend
7 .50 .38 .31 .25 .48 .37 .30 .25 .35 .29 .24 .33 .27 .23 .31 .26 .22 .21
165
0
0
0
0
0
0
90-150
256
8 .46 .35 .27 .22 .45 .34 .27 .22 .32 .26 .21 .30 .25 .21 .28 .24 .20 .18
175
0
0
0
0
0
0
90-180
256
0-deg
45-deg
90-deg
180
0
0
0
0
0
380
45˚
3 .71 .61 .53 .48 .68 .59 .52 .47 .55 .49 .45 .52 .47 .43 .48 .44 .41 .38
4 .64. 54 .46 .40 .62 .52 .44 .39 .48 .42 .37 .45 .40 .36 .43 .38 .34 .32
5 .59 .47 .39 .34 .56 .46 .39 .33 .43 .37 .32 .40 .35 .31 .38 .33 .29 .27
570
0˚
15˚
0-180 2383
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
30˚
6 .54 .42 .35 .29 .52 .41 .34 .28 .39 .32 .27 .36 .31 .27 .34 .29 .26 .24
9 .43 .32 .25 .20 .42 .31 .24 .20 .29 .23 .19 .28 .22 .18 .26 .21 .18 .16
10 .41 .29 .22 .18 .39 .28 .22 .18 .27 .21 .17 .26 .20 .17 .24 .20 .16 .15
1079
Lighting: Enclosed and Gasketed — Area — Fluorescent
0
5
Lighting
90
0
FR™ Enclosed and Gasketed; FZ™ and FD™ Hazardous Locations Luminaires
Nonmetallic Fluorescent. Photometric Data
4 foot, 2 lamp fixtures. High-impact fiberglass reinforced polyester fixtures suitable for use in wet and damp locations.
Candela Distribution
TOTAL LUMINAIRE EFFICIENCY = 80.7%
REPORT NUMBER: ITL 47242
0.0 22.5 45.0 67.5 90.0 Flux CIE Type – Semi-Direct
0 1224 1224 1224 1224 1224
0˚
Plane:
90˚
5 1228 1223 1221 1219 1218 116 Spacing Criteria: 1.3
Lamps: Two 40 W, 4-foot F40WW fluorescents,
3150 lumens per lamp with acrylic lens.
1.5
15 1185 1190 1204 1219 1222 341 Shielding Angles: 1
0
Lighting
25 1097 1122 1158 1200 1214 535
35
974 1020 1090 1166 1192 683
45
811 881 993 1094 1122 759
55
600 701 837 943 967 729
65
358 476 625 736 761 595
75
154 271 443 566 600 441
85
25 136 325 455 490 321
COEFFICIENTS OF UTILIZATION - ZONAL CAVITY METHOD
EFFECTIVE FLOOR CAVITY REFLECTANCE 0.20
90˚
90
5 101 285 401 442
ZONAL LUMEN
SUMMARY
95
5
84 260 372 415 253
ZONE LUMENS
105
2
45 187 294 343 184
0- 30
115
0
14
125
0
135
75˚
450
60˚
992
80
70
50
30
10
% Walls RW 70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10
0
0
0 .94 .94 .94 .94 .91 .91 .91 .91 .85 .85 .85 .79 .79 .79 .74 .74 .74 .72
1 .84 .79 .75 .71 .81 .76 .73 .69 .71 .68 .65 .67 .64 .62 .62 .60 .58 .56
2 .76 .68 .62 .57 .72 .66 .60 .55 .61 .57 .53 .57 .53 .50 .54 .50 .48 .45
900
85 163 204
91
0- 40 1676
3
23
53
81
28
0- 60 3164
0
0
9
16
20
7
0- 90 4521
145
0
0
0
5
7
2
90-120
528
155
0
0
0
0
0
0
90-130
556 Legend
7 .49 .37 .30 .25 .47 .36 .29 .24 .34 .28 .24 .32 .27 .23 .30 .26 .22 .20
165
0
0
0
0
0
0
90-150
564
8 .45 .34 .27 .22 .43 .33 .26 .22 .31 .25 .21 .29 .24 .20 .28 .23 .20 .18
175
0
0
0
0
0
0
90-180
564
0-deg
45-deg
90-deg
180
0
0
0
0
0
45˚
0˚
15˚
9 .42 .31 .24 .20 .40 .30 .24 .19 .29 .23 .19 .27 .22 .18 .26 .21 .18 .16
10 .39 .28 .22 .18 .38 .28 .22 .17 .26 .21 .17 .25 .20 .16 .24 .19 .16 .14
REPORT NUMBER: ITL 47243
0.0 22.5 45.0 67.5 90.0 Flux CIE Type – Semi-Direct
0˚
Plane:
4 .62 .52 .44 .39 .60 .50 .43 .38 .47 .41 .36 .44 .39 .35 .41 .37 .33 .31
6 .53 .41 .34 .28 .50 .40 .33 .28 .38 .32 .27 .35 .30 .26 .33 .29 .25 .23
30˚
TOTAL LUMINAIRE EFFICIENCY = 78.9%
0 1188 1188 1188 1188 1188
3 .68 .59 .52 .46 .66 .57 .51 .45 .53 .48 .43 .50 .45 .41 .47 .43 .40 .37
5 .57 .46 .39 .33 .55 .45 .38 .32 .42 .36 .31 .39 .34 .30 .37 .32 .29 .27
1350
0-180 5085
Candela Distribution
Lighting: Enclosed and Gasketed — Area — Fluorescent
% Ceiling RC
90˚
5 1188 1186 1186 1184 1183 113 Spacing Criteria: 1.3
Lamps: Two 40 W, 4-foot F40WW fluorescents,
3150 lumens per lamp with polycarbonate lens.
1.5
15 1146 1155 1165 1177 1181 330 Shielding Angles: 1
0
25 1060 1085 1122 1165 1178 519
35
940 984 1055 1135 1161 663
45
782 850 970 1073 1102 738
55
589 687 836 950 977 725
65
367 500 652 765 791 618
75
145 293 437 548 563 431
85
12 132 306 428 464 302
COEFFICIENTS OF UTILIZATION - ZONAL CAVITY METHOD
EFFECTIVE FLOOR CAVITY REFLECTANCE 0.20
90˚
% Ceiling RC
80
70
50
30
10
% Walls RW 70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10
0
0
90
4 106 270 381 421
ZONAL LUMEN
SUMMARY
95
5
86 244 348 389 240
ZONE LUMENS
105
2
42 178 278 321 172
115
0
8
82 163 201
88
0- 40 1624
125
0
1
19
54
82
27
0- 60 3087
135
0
0
8
16
18
6
0- 90 4438
145
0
0
1
5
8
2
90-120
500
155
0
0
0
0
0
0
90-130
527 Legend
7 .47 .36 .29 .24 .46 .35 .29 .24 .33 .27 .23 .31 .26 .22 .30 .25 .21 .20
165
0
0
0
0
0
0
90-150
535
8 .44 .33 .26 .21 .42 .32 .26 .21 .30 .25 .20 .29 .23 .20 .27 .23 .19 .17
175
0
0
0
0
0
0
90-180
535
0-deg
45-deg
90-deg
180
0
0
0
0
0
1080
0- 30
75˚
400
60˚
961
0-180 4973
0 .92 .92 .92 .92 .89 .89 .89 .89 .83 .83 .83 .78 .78 .78 .73 .73 .73 .70
1 .82 .78 .74 .70 .79 .75 .71 .68 .70 .67 .64 .65 .63 .61 .61 .59 .57 .55
2 .74 .67 .61 .55 .71 .64 .59 .54 .60 .55 .52 .56 .52 .49 .53 .49 .47 .44
800
45˚
3 .67 .58 .51 .45 .64 .56 .49 .44 .52 .47 .42 .49 .44 .41 .46 .42 .39 .37
4 .61 .51 .43 .38 .58 .49 .42 .37 .46 .40 .35 .43 .38 .34 .40 .36 .33 .31
5 .56 .45 .38 .32 .53 .44 .37 .31 .41 .35 .30 .38 .33 .29 .36 .32 .28 .26
1200
0˚
15˚
30˚
6 .51 .40 .33 .28 .49 .39 .32 .27 .37 .31 .26 .35 .29 .25 .33 .28 .24 .23
9 .41 .30 .24 .19 .39 .29 .23 .19 .28 .22 .18 .26 .21 .18 .25 .20 .17 .16
10 .38 .28 .21 .17 .37 .27 .21 .17 .26 .20 .16 .24 .19 .16 .23 .19 .15 .14
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
FE Series Nonmetallic Fluorescent Luminaires
Standard and Emergency Battery Back-Up. Increased Safety
Zone 1 & 2 – 21 & 22
II 2 GD
ATEX / IECEx
IP66/67 – IK10
Applications
• Can be installed in hazardous areas designated as Zone 1, 2, 21
and 22.
• For use in locations where a high degree of corrosion resistance
is required.
• For indoor/outdoor use where protection against dirt, water and
moisture is necessary.
• Typical applications include oil refineries, petrochemical
facilities, pulp and paper mills, food processing plants,
warehouses, underground tunnels and general manufacturing
facilities.
2 x 58 W
Features
•
•
•
•
•
Fiberglass reinforced polyester housing
Polycarbonate lens
Elastomer gasket
Highly reflective white polycarbonate internal reflector
Mounting accessories available in different materials such as
gray painted aluminum, zinc plated steel, galvanized steel or
316 stainless steel
Options
• Silicone coating for added protection in H2S hydrogen sulfide
environments.
• Without safety switch.
• Level gauge light fitting.
• 316 stainless steel fixing inserts.
2 x 18 W
EOL
Approved
Certifications and Compliances
•
•
•
•
•
•
•
•
•
•
•
•
•
•
Certification Type: FLe
Zones 1 and 2
— Conforming to ATEX 94/9/CE: CE 0081
II 2 G
— ATEX/IEC Protection: Ex de IIC or Ex demb IIC
(emergency version)
— T Rating: T5 ① to T4
Zone 21 and 22
— Conforming to ATEX 94/9/CE: CE 0081
II 2 D
— ATEX/IEC Protection: Ex tD A21
— Surface Temperature: 167 °F/75 °C
Ambient Temperature: -40 °F to 131 °F / -40 °C to 55 °C
CE Declaration of Conformity: 50201
ATEX Certificate: LCIE 07 ATEX 6017
IECEx Certificate: LCIE Ex 04.0017
Other Certifications: GOST, Marine Listed UL 1598A
Index of Protection (solid & liquid): IP66/67
Impact Resistance (shock): IK10
Ex Standards: EN / IEC 60079-0; 60079-1; 60079-7; 60079-18;
61241-0; 61241-1
Product Standards: EN / IEC 60598-1; 60598-2-22
EMC Standards: EN / IEC 55015; 61547
Other Standards: EN / IEC 60529 (IP); 62262 (IK)
① With ceiling position use at 104 °F/40 °C ambient temperature
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
1081
Lighting: Enclosed and Gasketed — Area — Fluorescent
Standard Materials
2 x 36 W
Lighting
• Corrosion-resistant fiberglass reinforced polyester body and
hinged polycarbonate lens.
• High impact resistance housing (20 Joules – IK10) from -40 °F to
131 °F / -40 °C to 55 °C ambient temperature and wind profile
for use in extreme offshore and onshore environments.
• Latch assembly and elastomer gasket seals against water and
dust ingress, IP66/67.
• Easily accessed for maintenance using Allen key or straight
blade screwdriver.
• Central opening with unique patented release system to prevent
damage.
• Hinged parabolic reflector for high lumen output efficiency.
• Vibration resistant spring loaded lampholders for bi-pin (G13) or
mono-pin (Fa6) versions.
• Positive safety switch disconnects power to lamps and ballast
to allow maintenance in hazardous locations.
• Electronic multi-tap ballast 110 to 254 Vac/Vdc +/- 10% 50/60
Hz, for global applications. High power factor electronic ballast
(>0.95). EOL (End Of Life) protection in accordance to the latest
EN/IEC 60079-7 standard.
• Two channel ballast prevents dark areas by allowing one lamp to
remain lit if one fails.
• Ballast plug-in with Ex e connector for quick and error-free
maintenance.
• Available in 3 hours emergency version, including multi-tap
ballast with built-in monthly self test. Test results through multicolored LED.
• Ex e battery with plug-in connector for maintenance in
hazardous location.
FE Series Nonmetallic Fluorescent Luminaires
Standard and Emergency Battery Back-Up. Increased Safety
Zone 1 & 2 – 21 & 22
II 2 GD
ATEX / IECEx
IP66/67 – IK10
Illustrated Features
Can be mounted horizontally or vertically
Order using catalog numbering guide below or select catalog number from tables on following pages.
Catalog Numbering Guide For FE Nonmetallic Fluorescent Lighting Fixtures
FE
B
1
Lighting
Series:
FE - FE Series
Zone 1, 2, 21, 22
ATEX / IEC Certified
BU
P
Wattage:
18 - 18 Watt
36 - 36 Watt
58 - 58 Watt
Lamp Type:
B - Bi-pin (G13)
M - Mono Pin (Fa6)
Lighting: Enclosed and Gasketed — Area — Fluorescent
18
Number of Lamps:
1 - Single
2 - Double
3 - Three Lamps
A
C
Cable Type:
A - Armored M20
N - Unarmored M25
U - Unarmored M20
Voltage:
BU - 110 to 254 Vac/Vdc
50/60 Hz
BK - 220 to 240 Vac/Vdc
50/60 Hz
Cable Type:
A - Armored M20
N - Unarmored M25
U - Unarmored M20
Mounting Version:
P - Pole Mount ①
S - Surface/Suspension Mount
Standard Wiring
T - Surface/Suspension Mount
Through Wiring
L - Surface/Suspension Mount
Dual Loop in/out Through
Wiring (single phase)
① Only 2 x 18 W and 2 x 36 W with M25 entry versions.
② Only 36 W and 58 W emergency versions.
③ Only for single standard versions.
④ Only for standard versions.
⑤ Only for S, T and L mounting versions.
1082
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
FE Series Nonmetallic Fluorescent Luminaires
Standard and Emergency Battery Back-Up. Increased Safety
Zone 1 & 2 – 21 & 22
II 2 GD
ATEX / IECEx
IP66/67 – IK10
Surface/Suspension Mounting and Standard Wiring Version
Connection via 1 x 6 terminals.
Capacity (flexible/solid): 4 mm2/6 mm2.
Unarmored Version - Bi-pin (G13)
Three M25 threaded entries, two at one end and one at opposite end, supplied with one
M25 polyamide cable gland (dia. 0.31 to 0.73" / 8 to 18.5 mm) and two M25 polyamide plugs.
Number
of Lamps
Power
(W)
Lamp
Type
Voltage
(V)
Weight
(lbs/kg)
Volume
(in3/dm3)
Catalog
Number
1
18
G13
110/254
12.13/5.5
1971.07/32.3
FEB118BUSN
2
18
G13
110/254
12.13/5.5
1971.07/32.3
FEB218BUSN
1
36
G13
110/254
17.42/7.9
3307.49/54.2
FEB136BUSN
2
36
G13
110/254
17.42/7.9
3307.49/54.2
FEB236BUSN
3
36
G13
110/254
21.83/9.9
3307.49/54.2
FEB336BUSN
1
58
G13
110/254
19.84/9
3966.54/65
FEB158BUSN
2
58
G13
110/254
19.84/9
3966.54/65
FEB258BUSN
3
58
G13
110/254
24.3/11
3966.54/65
FEB358BUSN
Armored Version - Bi-pin (G13)
Two M20 threaded entries with brass earth continuity plate at one end and
one M20 plugged clearance entry, supplied with two M20 polyamide plugs.
Lamp
Type
Voltage
(V)
Weight
(lbs/kg)
Volume
(in3/dm3)
Catalog
Number
1
18
G13
110/254
12.13/5.5
1971.07/32.3
FEB118BUSA
2
18
G13
110/254
12.13/5.5
1971.07/32.3
FEB218BUSA
1
36
G13
110/254
17.42/7.9
3307.49/54.2
FEB136BUSA
2
36
G13
110/254
17.42/7.9
3307.49/54.2
FEB236BUSA
3
36
G13
110/254
21.83/9.9
3307.49/54.2
FEB336BUSA
1
58
G13
110/254
19.84/9
3966.54/65
FEB158BUSA
2
58
G13
110/254
19.84/9
3966.54/65
FEB258BUSA
3
58
G13
110/254
24.3/11
3966.54/65
FEB358BUSA
Unarmored Version - Mono-pin (Fa6)
Three M25 threaded entries, two at one end and one at opposite end, supplied with
one M25 polyamide cable gland (dia. 0.31 to 0.73" / 8 to 18.5 mm) and two M25 polyamide plugs.
Catalog
Number
Number
of Lamps
Power
(W)
Lamp
Type
Voltage
(V)
Weight
(lbs/kg)
Volume
(in3/dm3)
2
18
Fa6
110/254
12.13/5.5
1971.07/32.3
FEM218BUSN
2
36
Fa6
110/254
17.42/7.9
3307.49/54.2
FEM236BUSN
2
58
Fa6
110/254
19.84/9
3966.54/65
FEM258BUSN
Armored Version - Mono-pin (Fa6)
Two M20 threaded entries with brass earth continuity plate at one end and one M20
plugged clearance entry supplied with two M20 polyamide plugs.
Catalog
Number
Number
of Lamps
Power
(W)
Lamp
Type
Voltage
(V)
Weight
(lbs/kg)
Volume
(in3/dm3)
2
18
Fa6
110/254
12.13/5.5
1971.07/32.3
FEM218BUSA
2
36
Fa6
110/254
17.42/7.9
3307.49/54.2
FEM236BUSA
2
58
Fa6
110/254
19.84/9
3966.54/65
FEM258BUSA
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
1083
Lighting: Enclosed and Gasketed — Area — Fluorescent
Power
(W)
Lighting
Number
of Lamps
FE Series Nonmetallic Fluorescent Luminaires
Standard and Emergency Battery Back-Up. Increased Safety
Zone 1 & 2 – 21 & 22
II 2 GD
ATEX / IECEx
IP66/67 – IK10
Surface/Suspension Mounting and Through Wiring Version (three phase)
Connection via 2 x 5 terminals.
Capacity (flexible/solid): 0.006 in2/0.009 in2 / 4 mm2/6 mm2.
Unarmored Version - Bi-pin (G13)
Three M25 threaded entries, two at one end and one at opposite end, supplied with two M25 polyamide cable
gland (dia. 0.31 to 0.73" / 8 to 18.5 mm) and one M25 polyamide plug.
Number
of Lamps
Power
(W)
Lamp
Type
Voltage
(V)
Weight
(lbs/kg)
Volume
(in3/dm3)
Catalog
Number
2
18
G13
110/254
12.13/5.5
1971.07/32.3
FEB218BUTN
2
36
G13
110/254
17.42/7.9
3307.49/54.2
FEB236BUTN
2
58
G13
110/254
19.84/9
3966.54/65
FEB258BUTN
Lighting: Enclosed and Gasketed — Area — Fluorescent
Lighting
Armored Version - Bi-pin (G13)
Two M20 threaded entries with brass earth continuity plate at one end and one M20 threaded
entry with brass earth continuity plate at opposite end, supplied with one M20 polyamide plug.
Number
of Lamps
Power
(W)
Lamp
Type
Voltage
(V)
Weight
(lbs/kg)
Volume
(in3/dm3)
Catalog
Number
2
18
G13
110/254
12.13/5.5
1971.07/32.3
FEB218BUTA
2
36
G13
110/254
17.42/7.9
3307.49/54.2
FEB236BUTA
2
58
G13
110/254
19.84/9
3966.54/65
FEB258BUTA
Surface/Suspension Mounting and Dual Loop In/Out Through
Wiring Version (single phase):
Connection via 1 x 6 terminals and 1 x 3 terminals.
Capacity (flexible/solid): 0.006in2/0.009in2 / 4 mm2/6 mm2.
Unarmored Version - Bi-pin (G13)
Three M25 entries, two at one end and one at opposite end, supplied with two M25 polyamide cable glands
(dia. 8 to 18.5 mm) and one M25 polyamide plug.
Number
of Lamps
Power
(W)
Lamp
Type
Voltage
(V)
Weight
(lbs/kg)
Volume
(in3/dm3)
Catalog
Number
2
18
G13
110/254
12.13/5.5
1971.07/32.3
FEB218BULN
2
36
G13
110/254
17.42/7.9
3307.49/54.2
FEB236BULN
2
58
G13
110/254
19.84/9
3966.54/65
FEB258BULN
Armored Version - Bi-pin (G13)
Two M20 threaded entries with brass earth continuity plate at one end and one M20 threaded
entry with brass earth continuity plate at opposite end, supplied with one M20 polyamide plug.
Number
of Lamps
Power
(W)
Lamp
Type
Voltage
(V)
Weight
(lbs/kg)
Volume
(in3/dm3)
Catalog
Number
2
18
G13
110/254
12.13/5.5
1971.07/32.3
FEB218BULA
2
36
G13
110/254
17.42/7.9
3307.49/54.2
FEB236BULA
2
58
G13
110/254
19.84/9
3966.54/65
FEB258BULA
1084
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
FE Series Nonmetallic Fluorescent Luminaires
Standard and Emergency Battery Back-Up. Increased Safety
Zone 1 & 2 – 21 & 22
II 2 GD
ATEX / IECEx
IP66/67 – IK10
Pole Mounting Version
Connection via 1 x 3 terminals.
Capacity (flexible/solid): 0.006 in2/0.009 in2 / 4 mm2/6 mm2.
For mounting on dia. 1.65"/42 mm pole or tubular wall-mounting support,
supplied with one integrated M25 polyamide cable gland
(dia. 0.31 to 0.73" / 8 to 18.5 mm).
Number
of Lamps
Power
(W)
Lamp
Type
Voltage
(V)
Weight
(lbs/kg)
Volume
(in3/dm3)
Catalog
Number
2
18
G13
110/254
13.67/6.2
2080.91/34.1
FEB218BUPN
2
36
G13
110/254
19.18/8.7
3307.49/54.2
FEB236BUPN
Level Gauge Tank Light Surface/Suspension Mounting with Standard Wiring
Connection via 1 x 6 terminals.
Capacity (flexible/solid): 0.006 in2/0.009 in2 / 4 mm2/6 mm2.
Unarmored Version - Bi-pin (G13)
Three M25 entries, two at one end and one at opposite end, supplied with
one M25 polyamide cable gland (dia. 0.31 to 0.73" / 8 to 18.5 mm) and two M25 polyamide plugs.
Power
(W)
Lamp
Type
Voltage
(V)
Weight
(lbs/kg)
Volume
(in3/dm3)
1
18
G13
110/254
12.13/5.5
1971.07/32.3
FEB118BUSNL
1
36
G13
110/254
17.42/7.9
3307.49/54.2
FEB136BUSNL
1
58
G13
110/254
19.84/9
3966.54/65
FEB158BUSNL
Catalog
Number
Lighting
Number
of Lamps
Lighting: Enclosed and Gasketed — Area — Fluorescent
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
1085
FE Series Nonmetallic Fluorescent Luminaires
Standard and Emergency Battery Back-Up. Increased Safety
Zone 1 & 2 – 21 & 22
II 2 GD
ATEX / IECEx
IP66/67 – IK10
Surface/Suspension Mounting and Standard Wiring
Connection via 1 x 4 terminals for 18 W version.
Connection via 1 x 8 terminals for
36 W & 58 W versions.
Capacity (flexible/solid): 0.006 in2/0.009 in2 /
4 mm2/6 mm2.
Unarmored Version - Bi-pin (G13)
Three M25 entries, two at one end and one at
opposite end, supplied with one
M25 polyamide cable gland (dia. 0.31 to 0.73" /
8 to 18.5 mm) and two M25 polyamide plugs.
Number
of Lamps
Power
(W)
Lamp
Type
Voltage
(V)
Weight
(lbs/kg)
Volume
(in3/dm3)
Duration
(Hours)
Battery
Capacity
2
2
2
3
2
2
3
18
36
36
36
58
58
58
G13
G13
G13
G13
G13
G13
G13
110/254
110/254
110/254
110/254
110/254
110/254
110/254
16.09/7.3
21.16/9.6
21.16/9.6
25.57/11.6
23.59/10.7
23.59/10.7
28.00/12.7
1971.07/32.3
3307.49/54.2
3307.49/54.2
3307.49/54.2
3966.54/65
3966.54/65
3966.54/65
3H
3H
3H
3H
3H
3H
3H
4Ah
4Ah
7Ah
4Ah
4Ah
7Ah
4Ah
Catalog
Number
FEB218BUSNE
FEB236BUSNE
FEB236BUSNE7
FEB336BUSNE
FEB258BUSNE
FEB258BUSNE7
FEB358BUSNE
Lighting: Enclosed and Gasketed — Area — Fluorescent
Lighting
Armored Version - Bi-pin (G13)
Two M20 threaded entries with brass earth continuity plate at one end and one
M20 plugged clearance entry, supplied with two M20 polyamide plugs.
Number
of Lamps
Power
(W)
Lamp
Type
Voltage
(V)
Weight
(lbs/kg)
Volume
(in3/dm3)
Duration
(Hours)
Battery
Capacity
2
2
2
3
2
2
3
18
36
36
36
58
58
58
G13
G13
G13
G13
G13
G13
G13
110/254
110/254
110/254
110/254
110/254
110/254
110/254
16.09/7.3
21.16/9.6
21.16/9.6
25.57/11.6
23.59/10.7
23.59/10.7
28.00/12.7
1971.07/32.3
3307.49/54.2
3307.49/54.2
3307.49/54.2
3966.54/65
3966.54/65
3966.54/65
3H
3H
3H
3H
3H
3H
3H
4 Ah
4 Ah
7 Ah
4 Ah
4 Ah
7 Ah
4 Ah
Catalog
Number
FEB218BUSAE
FEB236BUSAE
FEB236BUSAE7
FEB336BUSAE
FEB258BUSAE
FEB258BUSAE7
FEB358BUSAE
Unarmored Version - Mono-pin (Fa6)
Three M25 entries, two at one end and one at opposite end, supplied with one
M25 polyamide cable gland (dia. 0.31 to 0.73" / 8 to 18.5 mm) and two M25 polyamide plugs.
Number
of Lamps
Power
(W)
Lamp
Type
Voltage
(V)
Weight
(lbs/kg)
Volume
(in3/dm3)
Duration
(Hours)
Battery
Capacity
2
2
2
2
2
18
36
36
58
58
Fa6
Fa6
Fa6
Fa6
Fa6
110/254
110/254
110/254
110/254
110/254
16.76/7.6
21.83/9.9
21.83/9.9
24.25/11
24.25/11
1971.07/32.3
3307.49/54.2
3307.49/54.2
3966.54/65
3966.54/65
3H
3H
3H
3H
3H
4 Ah
4 Ah
7 Ah
4 Ah
7 Ah
Catalog
Number
FEM218BUSNE
FEM236BUSNE
FEM236BUSNE7
FEM258BUSNE
FEM258BUSNE7
Armored Version - Mono-pin (Fa6)
Two M20 threaded entries with brass earth continuity plate at one end and one
M20 plugged clearance entry, supplied with two M20 polyamide plugs.
Number
of Lamps
Power
(W)
Lamp
Type
Voltage
(V)
Weight
(lbs/kg)
Volume
(in3/dm3)
Duration
(Hours)
Battery
Capacity
2
2
2
2
2
18
36
36
58
58
Fa6
Fa6
Fa6
Fa6
Fa6
110/254
110/254
110/254
110/254
110/254
16.76/7.6
21.83/9.9
21.83/9.9
24.25/11
24.25/11
1971.07/32.3
3307.49/54.2
3307.49/54.2
3966.54/65
3966.54/65
3H
3H
3H
3H
3H
4 Ah
4 Ah
7 Ah
4 Ah
7 Ah
1086
Catalog
Number
FEM218BUSAE
FEM236BUSAE
FEM236BUSAE7
FEM258BUSAE
FEM258BUSAE7
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
FE Series Nonmetallic Fluorescent Luminaires
Standard and Emergency Battery Back-Up. Increased Safety
Zone 1 & 2 – 21 & 22
II 2 GD
ATEX / IECEx
IP66/67 – IK10
Surface/Suspension Mounting and Through Wiring Version
Connection via 2 x 4 terminals.
Capacity (flexible/solid):0.006 in2/0.009 in2 / 4 mm2/6 mm2.
Unarmored Version - Bi-pin (G13):
Three M25 entries, two at one end and one at opposite end, supplied
with two M25 polyamide cable glands (dia. 0.31 to 0.73" / 8 to 18.5 mm)
and one M25 polyamide plug.
Number
of Lamps
Power
(W)
Lamp
Type
Voltage
(V)
Weight
(lbs/kg)
Volume
(in3/dm3)
Duration
(Hours)
Battery
Capacity
2
18
Bi-pin
110/254
16.09/7.3
1971.07/32.3
3H
4 Ah
Catalog
Number
FEB218BUTNE
2
36
Bi-pin
110/254
21.16/9.6
3307.49/54.2
3H
4 Ah
FEB236BUTNE
2
36
Bi-pin
110/254
21.16/9.6
3307.49/54.2
3H
7 Ah
FEB236BUTNE7
2
58
Bi-pin
110/254
23.59/10.7
3966.54/65
3H
4 Ah
FEB258BUTNE
2
58
Bi-pin
110/254
23.59/10.7
3966.54/65
3H
7 Ah
FEB258BUTNE7
Armored Version - Bi-pin (G13):
Two M20 threaded entries with brass earth continuity plate at one end and one M20 threaded entry with brass earth continuity plate
at opposite end, supplied with one M20 polymaide plug.
Number
of Lamps
Power
(W)
Lamp
Type
Voltage
(V)
Weight
(lbs/kg)
Volume
(in3/dm3)
Duration
(Hours)
Battery
Capacity
Catalog
Number
18
Bi-pin
110/254
16.09/7.3
1971.07/32.3
3H
4 Ah
FEB218BUTAE
36
Bi-pin
110/254
21.16/9.6
3307.49/54.2
3H
4 Ah
FEB236BUTAE
2
36
Bi-pin
110/254
21.16/9.6
3307.49/54.2
3H
7 Ah
FEB236BUTAE7
2
58
Bi-pin
110/254
23.59/10.7
3966.54/65
3H
4 Ah
FEB258BUTAE
2
58
Bi-pin
110/254
23.59/10.7
3966.54/65
3H
7 Ah
FEB258BUTAE7
Lighting
2
2
Lighting: Enclosed and Gasketed — Area — Fluorescent
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
1087
FE Series Nonmetallic Fluorescent Luminaires
Standard and Emergency Battery Back-Up. Increased Safety
Zone 1 & 2 – 21 & 22
II 2 GD
ATEX / IECEx
IP66/67 – IK10
Surface/Suspension Mounting and Dual Loop
In/Out Through Wiring Version (single phase)
Connection via 1 x 4 double deck terminals for
18 W version.
Connection via 1 x 8 terminals and 1 x 4
terminals for 36 W & 58 W versions.
Capacity (flexible/solid): 0.006 in2/0.009 in2 /
4 mm2/6 mm2.
or
Lighting: Enclosed and Gasketed — Area — Fluorescent
Lighting
Unarmored Version - Bi-pin (G13)
Three M25 entries, two at one end and one
at opposite end, supplied with two M25
polyamide cable glands (dia. 0.31 to 0.73" /
8 to 18.5 mm) and one M25 polyamide plug.
18 W
36/58 W
Number
of Lamps
Power
(W)
Lamp
Type
Voltage
(V)
Weight
(lbs/kg)
Volume
(in3/dm3)
Duration
(Hours)
Battery
Capacity
Catalog
Number
2
18
Bi-pin
110/254
16.76/7.6
1971.07/32.3
3H
4 Ah
FEB218BULNE
2
36
Bi-pin
110/254
21.83/9.9
3307.49/54.2
3H
4 Ah
FEB236BULNE
2
36
Bi-pin
110/254
21.83/9.9
3307.49/54.2
3H
7 Ah
FEB236BULNE7
2
58
Bi-pin
110/254
23.59/10.7
3966.54/65
3H
4 Ah
FEB258BULNE
2
58
Bi-pin
110/254
23.59/10.7
3966.54/65
3H
7 Ah
FEB258BULNE7
Armored Version - Bi-pin (G13)
Two M20 threaded entries with brass earth continuity plate at one end and one M20
threaded entry with brass earth continuity plate at opposite end, supplied with one M20 polyamide plug.
Number
of Lamps
Power
(W)
Lamp
Type
Voltage
(V)
Weight
(lbs/kg)
Volume
(in3/dm3)
Duration
(Hours)
Battery
Capacity
Catalog
Number
2
18
Bi-pin
110/254
16.76/7.6
1971.07/32.3
3H
4 Ah
FEB218BULAE
2
36
Bi-pin
110/254
21.83/9.9
3307.49/54.2
3H
4 Ah
FEB236BULAE
2
36
Bi-pin
110/254
21.83/9.9
3307.49/54.2
3H
7 Ah
FEB236BULAE7
2
58
Bi-pin
110/254
23.59/10.7
3966.54/65
3H
4 Ah
FEB258BULAE
2
58
Bi-pin
110/254
23.59/10.7
3966.54/65
3H
7 Ah
FEB258BULAE7
Pole Mounting Version
Connection via 1 x 4 terminals.
Capacity (flexible/solid): 4 mm2/6 mm2.
18 W - Actual Size 2'/0.6m
36 W - Actual Size 4'/1.2m
For mounting on dia. 42 mm pole or tubular wall-mounting support, supplied with
one x M25 polyamide cable gland (dia. 0.31 to 0.73" / 8 to 18.5 mm).
Number
of Lamps
Power
(W)
Lamp
Type
Voltage
(V)
Weight
(lbs/kg)
Volume
(in3/dm3)
Duration
(Hours)
Battery
Capacity
Catalog
Number
2
18
Bi-pin
110/254
22.05/10
3307.49/54.2
3H
4 Ah
FEB218BUPNE
2
36
Bi-pin
110/254
22.93/10.4
3307.49/54.2
3H
4 Ah
FEB236BUPNE
2
36
Bi-pin
110/254
22.93/10.4
3307.49/54.2
3H
4 Ah
FEB236BUPNE7
Note: 2 x 18 W is supplied with external battery pack (see dimensional data).
1088
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
FE Series Nonmetallic Fluorescent Luminaires Accessories
Standard and Emergency Battery Back-Up. Increased Safety
Description
Pack
Catalog Number
Fixing Brackets
Set of two brackets for surface installation
Zinc plated steel
1
FEFBZ
316 stainless steel
1
FEFBS
Aluminum (gray painted)
1
FESBA
316 stainless steel
1
FESBS
1
FERBM8Z
Brackets for Surface Mounting
Set of two
M8 Ring Bolts
Set of two
Zinc plated steel
Half Clamps Brackets for Pole Mounting
Set of two
Dia. 1.65 to 1.93" / 42 to 49 mm pole (1.25 to 1.5" / 31.8 to 38.1 mm tube)
1
FEHC49Z
316 stainless steel
1
FEHC49S
Zinc plated steel
1
FEHC60Z
316 stainless steel
1
FEHC60S
1
FEWMG
Aluminum
1
FEHBA
316 stainless steel
1
FEHBS
Lighting
Zinc plated steel
Dia. 2.36"/60 mm pole (2"/50.8mm tube)
Lighting: Enclosed and Gasketed — Area — Fluorescent
Wall Mounting Adaptor
For pole mounting version (dia. 1.65"/42 mm)
Galvanized steel
Hinged Brackets
Set of two brackets for adjusting luminaire
Fall Prevention Kit
Safety chain retains fixture temporarily to ease installation
For M25 cable entry
1
FESCM25
For M20 cable entry
1
FESCM20
1
096905
Adaptor for Fa8 Tube on Fa6 Lampholder
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
1089
FE Series Nonmetallic Fluorescent Luminaire Technical Data
Standard and Emergency Battery Back-Up. Increased Safety
Zone 1 & 2 – 21 & 22
II 2 GD
ATEX / IECEx
IP66/67 – IK10
Wiring Diagram
Emergency Function Diagram
Two Lamp Version
Mains
PE
N
Mains
L
Lighting
Switch
Lighting Switch ON
Lighting Switch OFF
Lighting Switch ON
Lighting Switch OFF
ON
L’
U
N
PE
Standard Fluorescent
Lighting Fixture
OFF
Three Lamp Version
Mains
U’
U
N
PE
Emergency Fluorescent
Lighting Fixture
ON
Lighting
OFF
LED Status
Lighting: Enclosed and Gasketed — Area — Fluorescent
Color
Indication
Function
LED glows
Batteries are connected
LED blinks
Batteries are charged
Red
LED blinks
Batteries are not connected or defect
Yellow
LED blinks
Batteries are charging and discharging during automatic cycle
Green
Emergency Light Duration
Version
2 x 18 W
2 x 36 W
2 x 58 W
1090
Battery Capacity
Duration
Light Output
4 Ah – 6 V
3 hours
45%
4 Ah – 6 V
3 hours
15%
7 Ah – 6 V
3 hours
25%
4 Ah – 6 V
3 hours
9%
7 Ah – 6 V
3 hours
15%
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
FE Series Nonmetallic Fluorescent Luminaire Dimensions
Standard and Emergency Battery Back-Up. Increased Safety
Dimensions in Inches/Millimeters
Surface/Suspension Mounting
18 Watt
36 Watt
2 X MB
15.75"/
400.0 mm
2 X MB
27.56"/ 700.0 mm
54.72"/ 1390.0 mm
30.91"/785.0 mm
58 Watt
End View
2 X MB
27.56"/ 700.0 mm
5.71"/
145.0 mm
8.54"/
217.0 mm
66.54"/ 1690.0 mm
Pole Mounting
18 Watt
10.19"/
258.8
258.8
mm
Lighting
Ø 1.65"/
42.0 mm
End View
5.71"/
145.0 mm
1.99"/
50.0 mm
8.58”/
218.0 mm
30.91"/ 785.0 mm
36 Watt
Lighting: Enclosed and Gasketed — Area — Fluorescent
1.99"/
50.0 mm
54.72"/ 1390.0 mm
Emergency Pole Mounting
18 Watt
Ø 1.65"/
42.0 mm
End View
10.19"/
258.8 mm
3.58"/
91.0 mm
1.99"/
50.0 mm
4.72"/
120.0 mm
30.91"/ 785.0 mm
5.71"/
145.0 mm
8.58”/
218.0 mm
39.37"/ 1000.0 mm
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
1091
FE Series Nonmetallic Fluorescent Luminaires
Standard and Emergency Battery Back-Up. Increased Safety
Zone 1 & 2 – 21 & 22
II 2 GD
ATEX / IECEx
IP66/67 – IK10
Set of two quick fixing brackets for ease of surface
mounting Zinc plated steel or stainless steel
2.52"/
64 mm
0.35"/
9.0 mm
8.5
1.18"/
30 mm
0.33"/
8.5 mm
0.16"/
9.0 mm
0.98"/ 25.0 mm
1.93"/ 49.0 mm
Lighting
Set of two brackets for surface mounting.
Gray painted aluminum or stainless steel.
9.13"/ 232 mm
0.51"/
13.0 mm
0.37"/
9.59.5
mm
1.26"/
32.0 mm
0.57"/ 14.5 mm
14.5
Set of two ring bolts.
Zinc plated steel.
0.79"/
20.0 mm
0.31"/
8.0 mm
0.59"/
1.42"/
15.0 mm 36.0 mm
Lighting: Enclosed and Gasketed — Area — Fluorescent
1.50"/
38.0 mm
7.87"/ 200 mm
M 8 x 1.25
1092
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
FE Series Nonmetallic Fluorescent Luminaires
Standard and Emergency Battery Back-Up. Increased Safety
Zone 1 & 2 – 21 & 22
II 2 GD
ATEX / IECEx
IP66/67 – IK10
Set of two clamps for pole dia. 1.65”/42 mm to 2.36”/60 mm
(1-1/4" to 2"). Zinc plated steel or stainless steel.
95 for 1.25"/31.8 mm
or 1.50"/38.1mm
2.95”/
75.0 mm
0.55”/
14.0 mm
or 84 for 2.00"/50.8mm
1.25"/31.8 mm
or 1.50"/38.1mm
”/
36
2. m
Ø 0m
6
3.31”/
85 mm
0.55”/
14.0 mm
2.00"/50.8mm
1.65”/42 mm dia. galvanized steel wall mounting pole.
0.47”/
12.0 mm
Lighting
m
0.0 m
2”/43
16.9
Ø 0.79”/
20.0 mm
5.51”/140.0 mm
”/
1.65 m
m
42.0
0.20”/5.0 mm
mm
/75.0
2.95”
5.98”/152.0 mm
5.04”/128.0 mm
Lighting: Enclosed and Gasketed — Area — Fluorescent
Ø 0.41”/
10.5 mm
Set of two hinged brackets for adjusting luminaire.
Gray painted aluminum or stainless steel.
1.26”/
32.0 mm
0.22”/
5.5 mm
3
77 .03”
.0 /
mm
3
82 .23
.0 ”/
mm
0.71”/
18.0 mm
30
60
90
0
90
30°
1.61”/
41.0 mm
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
0.57”/
14.5 mm
5.20”/132 mm
60
3.94”/
100.0 mm
30°
30
M8x1.25"/
31.8 mm
0.51”/
0.37”/
13.0 mm
9.5 mm
1093
FE Series Nonmetallic Fluorescent Luminaire Photometric Data
Standard and Emergency Battery Back-Up. Increased Safety
Longitudinal
Transverse
Polar curves for a 1000 lm flux, according to NF C 71-120
Luminaire symbol according to NF C 71-121
1 x 36 W
Efficiency 89.3%
NF C 71-121: 0.81 H + 0.08 T
1 x 18 Watt
TOTAL LUMINAIRE EFFICIENCY = 94.8%
NF C 71-121: 0.86 H + 0.09 T
Candela Distribution
Candela Distribution
0-180 90-270
0-180 90-270
Lighting
Candela Distribution
0-180 90-270
0
215
215
0
205
205
0
198
5
214 Degrees214
5
204 Degrees203
5
197Degrees 197
198
211
215
90°
10
202
203
90°
10
194
198
90°
15
207
213
75°
15
197
202
75°
15
190
197
75°
20
200
211
20
191
201
20
184
195
25
191
209
25
182
201
25
176
194
30
181
208
30
173
200
30
166
193
35
169
202
35
161
192
35
155
187
40
155
196
40
148
183
40
142
180
45
139
187
45
133
177
45
128
174
50
122
181
50
117
173
50
113
170
55
103
175
55
99
168
55
96
167
60
83
174
60
80
168
60
78
163
65
62
173
65
61
163
65
59
157
70
42
165
70
41
154
70
41
151
10
Lighting: Enclosed and Gasketed — Area — Fluorescent
1 x 58 W
Efficiency 87.5%
NF C 71-121: 0.80 H + 0.07 T
60°
45°
30°
0°
15°
2 x 18 W
Efficiency 85.1%
NF C 71-121: 0.78 H + 0.08 T
0
5
10
15
20
25
30
35
40
45
50
55
60
65
70
90°
75°
60°
45°
30°
0°
15°
3 x 18 W
Efficiency 68.1%
NF C 71-121: 0.63 G + 0.05 T
Candela Distribution
0-180 90-270
0
185 Degrees185
5
185
184
10
182
182
15
178
181
20
172
183
25
164
183
30
154
183
35
143
183
40
131
183
45
117
179
50
102
173
55
85
166
60
68
155
65
51
145
70
35
141
Candela Distribution
0-180 90-270
173 Degrees173
172
172
169
170
135
169
160
169
153
168
144
167
135
162
123
158
110
153
96
146
82
136
66
123
50
111
34
100
0-180 90-270
174 Degrees174
174
174
171
173
167
171
162
171
155
170
146
168
136
163
125
159
112
153
98
145
83
135
67
123
51
110
35
100
1094
30°
0°
15°
90°
75°
60°
45°
30°
0°
15°
0
5
10
15
20
25
30
35
40
45
50
55
60
65
70
60°
45°
30°
0°
15°
2 x 58 W
Efficiency 76.9%
NF C 71-121: 0.70 H + 0.07 T
90°
75°
60°
45°
30°
0°
15°
3 x 36 W
Efficiency 68.1%
NF C 71-121: 0.63 G + 0.07 T
Candela Distribution
0
5
10
15
20
25
30
35
40
45
50
55
60
65
70
45°
2 x 36 W
Efficiency 80.5%
NF C 71-121: 0.73 H + 0.07 T
Candela Distribution
0-180 90-270
195 Degrees195
195
194
192
192
187
192
181
193
173
194
163
194
152
193
138
192
124
191
108
183
91
176
73
163
55
150
37
145
60°
Candela Distribution
0-180 90-270
0
173Degrees 173
5
172
173
10
170
171
15
166
169
20
161
172
25
154
172
30
145
172
35
135
171
40
123
172
45
111
170
50
97
165
55
82
157
60
66
148
65
50
139
70
34
133
90°
75°
60°
45°
30°
0°
15°
3 x 58 W
Efficiency 65.6%
NF C 71-121: 0.61 H + 0.04 T
Candela Distribution
90°
75°
60°
45°
30°
0°
15°
0
5
10
15
20
25
30
35
40
45
50
55
60
65
70
0-180 90-270
170Degrees 170
170
170
167
168
163
169
158
167
151
167
143
163
133
159
122
155
109
149
95
140
81
129
65
116
49
105
33
96
90°
75°
60°
45°
30°
0°
15°
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
FL Series Light Duty Nonmetallic Fluorescent Luminaires
Standard and Emergency Back-Up. Zone 2 & 22
Zone 2 & 22
II 3 GD
ATEX - IEC IP65/67
Applications
• Light duty luminaire ideal for commercial and light industrial
locations including hazardous areas designated as Zone 2 or
22 environments.
• Typical applications include oil refineries petrochemical
plants, pulp and paper mills, tunnels and other light duty
manufacturing locations.
2 x 58 W
Features
•
•
•
•
Utilizes two 26 mm (T8) bi-pin fluorescent lamps.
Fiberglass reinforced polyester housing.
Instant start 95% power factor ballast.
Available in various lengths and wattages ranging from 18 to 58.
Pre-impregnated fiberglass reinforced white polyester housing.
• Closing system using stainless steel clips.
• Electrostatically applied white powder painted steel reflector
provides optimal lighting distribution.
• Poured-in-place elastomer gasket secures IP65 / 67 ingress
protection.
Standard Material
•
•
•
•
•
•
Options
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
•
•
Certification Type: EFn (Standard Version) / EFn-EM
(Emergency Version
Zone 2
— Conforming to ATEX 94/9/CE: CE II 3 G
— ATEX/IEC Protection: Ex nR II or Ex nA II
— T Rating: T4 for nA protection mode.
See temperature chart for nR protection mode
• Zone 22
— Conforming to ATEX 94/9/CE: CE
II 3 D
— ATEX/IEC Protection: Ex tD A22
— Surface Temperature: (See table)
• Ambient Temperature: -4 °F to 131 °F / -20 °C to +55 °C
• CE Declaration of Conformity: 50213/50219
• ATEX Certificate: LCIE 08.6005X / LCIE 08.6063X
• IECEx Certificate: LCIE Ex 08.007X / LCIE Ex 08.008X
• Index of Protection (solid & liquid): IP65 / 67
• Time Before Opening: 10mn
• Ex Standards: EN / IEC 60079-15; 61241-0; 61241-1
• Product Standards: EN / IEC 60598-1; 60598-2-22
• EMC Standards: EN / IEC 55015; 61547
• Other Standards: EN / IEC 60529 (IP)
Lighting: Enclosed and Gasketed — Area — Fluorescent
• Available in 3 hours emergency version, including multi-tap
ballast with built-in monthly self test. Test results through multicolored LED.
• Plug-in battery pack is easy to remove for maintenance.
• Battery voltage is 6 volts and 4 Ah capacity.
• One fluorescent tube remains lit for up to 3 hours and up to 29%
light intensity for 18 Watt, 15% for 36 Watt and 9% for 58 Watt.
• All emergency units supplied with cut off switch to battery when
fixture is opened.
Certifications and Compliances
Lighting
Fiberglass reinforced polyester (FRP) housing
Polycarbonate lens
White powder painted sheet steel reflector
Elastomer gasket
Polycarbonate lampholders
Mounting accessories available in different materials such
as gray painted aluminum, zinc plated steel, galvanized steel
or 316 stainless steel
2 x18 W
1095
FL Series Light Duty Nonmetallic Fluorescent Luminaires
Standard and Emergency Back-Up. Zone 2 & 22
Zone 2 & 22
II 3 GD
ATEX - IEC IP65/67
Order using catalog numbering guide below or select catalog number from tables on following pages.
Catalog Numbering Guide For FN Non-Metallic Fluorescent Lighting Fixtures
FN
B
1
18
BU
Wattage:
18 - 18 Watt
36 - 36 Watt
58 - 58 Watt
55 - 55 Watt
80 - 80 Watt
Series:
FN - FN Series
Zone 2, 21 & 22
ATEX/IEC Certified
Lamp Type:
B - Bi-pin (G13)
C - PL Compact Lamps
(2G11) ②
A
C
Cable Type:
A - Armored M20
N - Unarmored M25
U - Unarmored M20
Voltage:
BU - 110 to 254 Vac/Vdc
50/60 Hz
BK - 220 to 240 Vac/Vdc
50/60 Hz
Options:
(Options must be listed
alphabetically)
C - Silicon Coating for
Diffuser
E - 3H Emergency
(combined) - Battery
6 V - 4 Ah
N - No Switch ③
X - 4 Entries ④
Mounting Version:
P - Pole Mount ①
S - Surface/Suspension Mount
Standard Wiring
T - Surface/Suspension Mount
Through Wiring
L - Surface/Suspension Mount
Dual Loop in/out Through
Wiring (single phase)
Lighting
Number of Lamps:
1 - Single
2 - Double
3 - Three Lamps
Lighting: Enclosed and Gasketed — Area — Fluorescent
P
Temperature Chart
Version
1 x 18 W
2 x 18 W
1 x 36 W
2 x 36 W
1 x 58 W
2 x 58 W
Dust
Surface
Temp.
167°F/75°C
181°F/83°C
196°F/91°C
T Rating for Ta =
104° F/40° C
Gas
T Rating for Ta =
122°F/50°C
T Rating for Ta =
131°F/55°C
T6
T6
T6
T6
T5
T5
T6
T6
T5
T6
T6
T5
T5
T5
T5
T5
T5
T5
① Only 2 x 18 W and 2 x 36 W with M25 entry versions.
② Only 55 W and 80 W standard versions.
③ Only for standard versions.
④ Only for S, T and L mounting versions.
1096
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
FL Series Light Duty Nonmetallic Fluorescent Luminaires
Standard and Emergency Back-Up. Zone 2 & 22
Zone 2 & 22
II 3 GD
ATEX - IEC IP65/67
Standard Version for Armored and Unarmored Cable
Supplied with one M20 cable entry at each end plus two locknuts, two earth continuity and one blanking plug.
Also supplied with one 2 x (0.004 x 0.003 in2 / 3 x 2.5 mm2) max. flexible or rigid connection terminal block.
Number
of Lamps
Watts
Voltage
(V)
Weight
(lbs/kg)
Volume
(in3/dm3)
Pack.
Catalog
Number
1
18
220/240
5.07/2.3
1360.83/22.3
1
FLB118BKSA
2
18
220/240
5.07/2.3
1360.83/22.3
1
FLB218BKSA
2
18
110/254
5.07/2.3
1360.83/22.3
1
FLB218BUSA
1
36
220/240
6.17/2.8
2318.90/38
1
FLB136BKSA
1
36
110/254
6.17/2.8
2318.90/38
1
FLB136BUSA
2
36
220/240
7.94/3.6
2318.90/38
1
FLB236BKSA
2
36
110/254
7.94/3.6
2318.90/38
1
FLB236BUSA
1
58
220/240
7.50/3.4
2746.07/45
1
FLB158BKSA
1
58
110/254
7.50/3.4
2746.07/45
1
FLB158BUSA
2
58
220/240
9.70/4.4
2746.07/45
1
FLB258BKSA
2
58
110/254
9.70/4.4
2746.07/45
1
FLB258BUSA
Lighting
Emergency Version for Armored and Unarmored Cable
Supplied with one M20 entries with earth continuity at each end. Also supplied with two M20 locknuts and one blanking plug.
Equipped with one 2 x (0.008 x 0.003 in2 / 5 x 2.5 mm2) max. flexible or rigid connection terminal block
Watts
Voltage
(V)
Weight
(lbs/kg)
Volume
(in3/dm3)
Pack.
Catalog
Number
2
18
110/254
9.92/4.5
1360.83/22.3
1
FLB218BUSAE
2
36
110/254
15.43/7.0
2318.90/38
1
FLB236BUSAE
2
58
110/254
16.53/7.5
2746.07/45
1
FLB258BUSAE
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
1097
Lighting: Enclosed and Gasketed — Area — Fluorescent
Number
of Lamps
FL Series Light Duty Nonmetallic Fluorescent Luminaire Accessories
Standard and Emergency Back-Up. Zone 2 & 22
Zone 2 & 22
II 3 GD
ATEX - IEC IP65/67
Description
Pack
Catalog Number
Fixing Brackets
Set of two brackets for surface installation
Zinc plated steel
1
FEFBZ
316 stainless steel
1
FEFBS
Aluminum (gray painted)
1
FESBA
316 stainless steel
1
FESBS
1
FERBM8Z
Brackets for Surface Mounting
Set of two
M8 Ring Bolts
Set of two
Zinc plated steel
Half Clamps Brackets for Pole Mounting
Set of two
Lighting
Dia. 1.65 to 1.93" / 42 to 49 mm pole (1.25 to 1.5" / 31.8 to 38.1 mm tube)
Zinc plated steel
1
FEHC49Z
316 stainless steel
1
FEHC49S
Zinc plated steel
1
FEHC60Z
316 stainless steel
1
FEHC60S
Aluminum
1
FEHBA
316 stainless steel
1
FEHBS
1.20 M stainless steel chain
1
FDSCS
Lighting: Enclosed and Gasketed — Area — Fluorescent
Dia. 2.36"/60 mm pole (2"/50.8mm tube)
Hinged Brackets
Set of two brackets for adjusting luminaire
Fall Prevention Kit
1098
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
FL Series Light Duty Nonmetallic Fluorescent Luminaire Technical Data
Standard and Emergency Back-Up. Zone 2 & 22
Zone 2 & 22
II 3 GD
ATEX - IEC IP65/67
Emergency Function Diagram — Emergency Function 2 Tubes
Mains
Lighting Switch ON
Lighting Switch OFF
Fluorescent Luminaire ON
Fluorescent Luminaire OFF
Photometric Data
Longitudinal
Transverse
Polar curves for a 1000 lm flux, according to NF C 71-120
Luminaire symbol according to NF C 71-121
1 x 18 W
Efficiency 67.8%
NF C 71-121: 0.58 H + 0.09 T
2 x 18 W
Efficiency 68.9%
NF C 71-121: 0.60 H + 0.09 T
Candela Distribution
90-270
0
142
142
5
142
142
10
139
140
15
135
135
20
130
132
25
123
128
30
113
126
35
102
128
90
132
78
136
50
66
134
55
54
131
60
43
129
0-180
116
116
90°
5
115
119
10
113
133
75°
15
110
150
20
105
156
25
100
157
Degrees
60°
45°
30°
0°
90-270
0
15°
30
94
158
35
88
159
40
81
158
45
74
157
50
65
152
55
55
145
60
45
137
65
33
119
65
35
128
70
23
110
70
25
114
2 x 36 W
Efficiency 64.1%
NF C 71-121: 0.57 H + 0.07 T
0
5
10
15
20
25
30
35
40
45
50
55
60
65
70
90°
75°
60°
45°
30°
0°
15°
2 x 58 W
Efficiency 63.6%
NF C 71-121: 0.56 H + 0.07 T
Candela Distribution
0-180
163
162
160
155
149
142
132
120
104
80
60
50
40
31
23
Degrees
Lighting: Enclosed and Gasketed — Area — Fluorescent
40
45
Candela Distribution
Lighting
0-180
90-270
163
162
159
145
140
139
139
138
134
133
129
125
120
108
95
Candela Distribution
Degrees
90°
75°
60°
45°
30°
0°
15°
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
0
5
10
15
20
25
30
35
40
45
50
55
60
65
70
0-180
160
159
157
153
148
141
132
121
107
85
68
56
45
35
24
90-270
160
160
157
146
140
139
139
138
134
132
127
122
117
107
90
Degrees
90°
75°
60°
45°
30°
0°
15°
1099
FN Series Heavy Duty Nonmetallic Fluorescent Luminaires
Standard and Emergency Back-Up. Zone 2 - 21 & 22
Zone 2 - 21 & 22
II 3 GD and II 2 D
ATEX / IECEx
IP66/67 - IK10
Applications
• Can be installed in hazardous areas designated as Zone 2,
21 and 22.
• For use in locations where a high degree of corrosion resistance
is required.
• For indoor/outdoor use where protection against dirt, water and
moisture is necessary.
• Typical applications include oil refineries, petrochemical
facilities, pulp and paper mills, food processing plants,
warehouses, underground tunnels and general
manufacturing facilities.
2 x 58 W
Lighting: Enclosed and Gasketed — Area — Fluorescent
Lighting
Features
• Corrosion-resistant fiberglass reinforced polyester body and
hinged polycarbonate lens.
• High impact resistance housing (20 Joules - IK10) from
-40° F to 131 °F / -40°C to 55 °C ambient temperature
and wind profile for use in extreme offshore and onshore
environments.
• Latch assembly and elastomer gasket seals against water and
dust ingress, IP66/67.
• Easily accessed for maintenance using Allen key or straight
blade screw driver.
• Central opening with unique patented release system to
prevent damage.
• Hinged parabolic reflector for high lumen output efficiency.
• Vibration resistant spring loaded lampholders for Bi-pin (G13) or
mono-pin (Fa6) versions.
• Electronic multi-tap ballast 110 to 254 Vac/Vdc +/- 10% 50/60
Hz, for global applications. High power factor electronic ballast
(>0.95). EOL (End Of Life) protection in accordance to the latest
EN/IEC 60079-7 standard.
• Also available with electronic ballast 220/240 Vac/Vdc +/- 10%
50/60 Hz. High power factor electronic ballast (>0.95). EOL.
• Available in 3 hours emergency version, including multi-tap
ballast with built-in monthly self test. Test results through
multi-color LED.
Standard Material
•
•
•
•
•
Fiberglass reinforced polyester housing
Polycarbonate lens
Elastomer gasket
Highly reflective white polycarbonate internal reflector
Mounting accessories available in different materials such as
gray painted aluminum, zinc plated steel, galvanized steel or
316 stainless steel
Options
• Silicone coating for added protection in H2S hydrogen
sulfide environments.
• Without safety switch.
• Level gauge light fitting.
• 316 stainless steel fixing inserts.
1100
2 x 36 W
2 x 18 W
Certifications and Compliances
•
•
•
•
•
•
•
•
•
•
•
•
•
•
Certification Type: FLd
Zone 2
— Conforming to ATEX 94/9/CE: CE
II 3 G
— ATEX/IEC Protection: Ex nR II or Ex nA II
— T Rating: T6 to T4
Zone 21 and 22
— Conforming to ATEX 94/9/CE: CE
II 2 D, CE
II 3 D
— ATEX/IEC Protection: Ex tD A21
— Surface Temperature: T167 °F/75 °C
Ambient Temperature: -40 °F to 131 °F / -40 °C to 55 °C
CE Declaration of Conformity: 50212/50225
ATEX Certificate: LCIE 03 ATEX 6072/6166
IECEx Certificate: IECEx LCI 04.0021
Other Certifications: GOST, Marine Listed UL 1598A
Index of Protection (solid & liquid): IP66/67
Impact Resistance (shock): IK10
Ex Standards: EN / IEC 60079-15; 61241-0; 61241-1
Product Standards: EN / IEC 60598-1; 60598-2-22
EMC Standards: EN / IEC 55015; 61547
Other Standards: EN / IEC 60529 (IP); 62262 (IK)
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
FN Series Heavy Duty Nonmetallic Fluorescent Luminaires
Standard and Emergency Back-Up. Zone 2 - 21 & 22
Zone 2 - 21 & 22
II 3 GD and
II 2 D
ATEX / IECEx
IP66/67 - IK10
Order using catalog numbering guide below or select catalog number from tables on following pages.
Catalog Numbering Guide For FN Non-Metallic Fluorescent Lighting Fixtures
FN
B
1
18
BU
P
Wattage:
18 - 18 Watt
36 - 36 Watt
58 - 58 Watt
55 - 55 Watt
80 - 80 Watt
Series:
FN - FN Series
Zone 2, 21 & 22
ATEX/IEC Certified
Lamp Type:
B - Bi-pin (G13)
C - PL Compact Lamps
(2G11) ②
Number of Lamps:
1 - Single
2 - Double
3 - Three Lamps
A
C
Cable Type:
A - Armored M20
N - Unarmored M25
U - Unarmored M20
Voltage:
BU - 110 to 254 Vac/Vdc
50/60 Hz
BK - 220 to 240 Vac/Vdc
50/60 Hz
Options:
(Options must be listed
alphabetically)
C - Silicon Coating for
Diffuser
E - 3H Emergency
(combined) - Battery
6 V - 4 Ah
N - No Switch ③
X - 4 Entries ④
Lighting
Mounting Version:
P - Pole Mount ①
S - Surface/Suspension Mount
Standard Wiring
T - Surface/Suspension Mount
Through Wiring
L - Surface/Suspension Mount
Dual Loop in/out Through
Wiring (single phase)
Lighting: Enclosed and Gasketed — Area — Fluorescent
① Only 2 x 18 W and 2 x 36 W with M25 entry versions.
② Only 55 W and 80 W standard versions.
③ Only for standard versions.
④ Only for S, T and L mounting versions.
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
1101
FN Series Heavy Duty Nonmetallic Fluorescent Luminaires
Standard and Emergency Back-Up. Zone 2 - 21 & 22
Zone 2 - 21 & 22
II 3 GD and II 2 D
ATEX / IECEx
IP66/67 - IK10
Standard Version
Surface/Suspension Mounting and Standard Wiring
Version
Connection via 1 x 6 terminals.
Capacity (flexible/solid): 0.006 in2/0.009 in2 / 4 mm2/6 mm2.
Unarmored Version - Bi-pin (G13)
Three M25 threaded entries, two at one end and one at opposite end, supplied with one
M25 polyamide cable gland (dia. 0.31 to 0.73" / 8 to 18.5 mm) and two M25 polyamide blanking plugs.
Catalog
Number
FNB218BKSNN
FNB218BUSNN
FNB236BKSNN
FNB236BUSNN
FNB258BKSNN
FNB258BUSNN
Lighting
Number
Power
Lamp
Voltage
Weight
Volume
of Lamps
(W)
Type
(V)
(lbs/kg)
(in3/dm3)
2
18
G13
220/240
12.13/5.5
1971.07/32.3
2
18
G13
110/254
12.13/5.5
1971.07/32.3
2
36
G13
220/240
17.42/7.9
3307.49/54.2
2
36
G13
110/254
17.42/7.9
3307.49/54.2
2
58
G13
220/240
19.84/9
3966.54/65
2
58
G13
110/254
11
3966.54/65
Armored Version - Bi-pin (G13)
Two M20 threaded entries with brass earth continuity plate at one end and
one M20 plugged clearance entry, supplied with two M20 polyamide plugs.
Number
of Lamps
2
2
2
2
2
2
Power
(W)
18
18
36
36
58
58
Lamp
Type
G13
G13
G13
G13
G13
G13
Voltage
(V)
220/240
110/254
220/240
110/254
220/240
110/254
Weight
(lbs/kg)
12.13/5.5
12.13/5.5
17.42/7.9
17.42/7.9
19.84/9
24.25/11
Volume
(in3/dm3)
1971.07/32.3
1971.07/32.3
3307.49/54.2
3307.49/54.2
3966.54/65
3966.54/65
Catalog
Number
FNB218BKSAN
FNB218BUSAN
FNB236BKSAN
FNB236BUSAN
FNB258BKSAN
FNB258BUSAN
Lighting: Enclosed and Gasketed — Area — Fluorescent
Emergency Version
Surface/Suspension Mounting and Standard Wiring
Connection via 1 x 4 terminals for 18 W version.
Connection via 1 x 8 terminals for 36 W & 58 W
versions.
Capacity (flexible/solid): 4 mm2/6 mm2.
18 W
36/58 W
Unarmored Version - Bi-pin (G13)
Three M25 entries, two at one end and one at opposite end, supplied with
one M25 polyamide cable gland (dia. 0.31 to 0.73" / 8 to 18.5 mm) and two
M25 polyamide blanking plugs.
Number
Power
Lamp
Voltage
Weight
Volume
of Lamps
(W)
Type
(V)
(lbs/kg)
(in3/dm3)
2
18
G13
110/254
16.09/7.3
1971.07/32.3
2
36
G13
110/254
21.16/9.6
3307.49/54.2
2
58
G13
110/254
23.59/10.7
3966.54/65
Armored Version - Bi-pin (G13)
Two M20 threaded entries with brass earth continuity plate at one end and
one M20 plugged clearance entry, supplied with two M20 polyamide plugs.
Number
of Lamps
2
2
2
1102
Power
(W)
18
36
58
Lamp
Type
G13
G13
G13
Voltage
(V)
110/254
110/254
110/254
Weight
(lbs/kg)
16.09/7.3
21.16/9.6
23.59/10.7
Volume
(in3/dm3)
1971.07/32.3
3307.49/54.2
3966.54/65
Duration
(Hours)
3H
3H
3H
Battery
Capacity
4 Ah
4 Ah
4 Ah
Catalog
Number
FNB218BUSNEN
FNB236BUSNEN
FNB258BUSNEN
Duration
(Hours)
3H
3H
3H
Battery
Capacity
4 Ah
4 Ah
4 Ah
Catalog
Number
FNB218BUSAEN
FNB236BUSAEN
FNB258BUSAEN
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
FN Series Heavy Duty Nonmetallic Fluorescent Luminaire Accessories
Standard and Emergency Back-Up. Zone 2 - 21 & 22
Zone 2 - 21 & 22
II 3 GD and II 2 D
ATEX / IECEx
IP66/67 - IK10
Description
Pack
Catalog Number
Fixing Brackets
Set of two brackets for surface installation
Zinc plated steel
1
FEFBZ
316 stainless steel
1
FEFBS
Aluminum (gray painted)
1
FESBA
316 stainless steel
1
FESBS
1
FERBM8Z
Brackets for Surface Mounting
Set of two
M8 Ring Bolts
Set of two
Zinc plated steel
Half Clamps Brackets for Pole Mounting
Set of two
Dia. 1.65 to 1.93" / 42 to 49 mm pole (1.25 to 1.5" / 31.8 to 38.1 mm tube)
1
FEHC49Z
316 stainless steel
1
FEHC49S
Zinc plated steel
1
FEHC60Z
316 stainless steel
1
FEHC60S
1
FEWMG
Aluminum
1
FEHBA
316 stainless steel
1
FEHBS
Lighting
Zinc plated steel
Dia. 2.36"/60 mm pole (2"/50.8mm tube)
Lighting: Enclosed and Gasketed — Area — Fluorescent
Wall Mounting Adaptor
For pole mounting version (dia. 1.65"/42 mm)
Galvanized steel
Hinged Brackets
Set of two brackets for adjusting luminaire
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
1103
FN Series Heavy Duty Nonmetallic Fluorescent Luminaire Technical Data
Standard and Emergency Back-Up. Zone 2 - 21 & 22
Zone 2 - 21 & 22
II 3 GD and II 2 D
ATEX / IECEx
IP66/67 - IK10
Wiring Diagram
Emergency Function Diagram
Two Lamp Version
Mains
PE
N
Mains
L
Lighting
Switch
Lighting Switch ON
Lighting Switch OFF
Lighting Switch ON
Lighting Switch OFF
ON
L’
U
N
PE
OFF
Standard Fluorescent
Lighting Fixture
Three Lamp Version
Mains
U’
U
N
PE
ON
Emergency Fluorescent
Lighting Fixture
Lighting
OFF
LED Status
Color
Indication
Green
Lighting: Enclosed and Gasketed — Area — Fluorescent
Function
LED glows
Batteries are connected
LED blinks
Batteries are charged
Red
LED blinks
Batteries are not connected or defect
Yellow
LED blinks
Batteries are charging and discharging during automatic cycle
Dimensions
Surface/Suspension Mounting
18 W
36 W
2 X MB
15.75"/
400 mm
27.56"/ 700.0 mm
30.91"/785.0mm
2 X MB
54.72"/ 1390.0 mm
5.71"/
145.0 mm
58 W
27.56"/ 700.0 mm
2 X MB
66.54"/ 1690.0 mm
8.54"/
217.0 mm
1104
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
FN Series Heavy Duty Nonmetallic Fluorescent Luminaire Photometric Data
Standard and Emergency Back-Up. Zone 2 - 21 & 22
Longitudinal
Transverse
Polar curves for a 1000 lm flux, according to NF C 71-120
Luminaire symbol according to NF C 71-121
2 x 18 W
Efficiency 85.1%
NF C 71-121: 0.78 H + 0.08 T
2 x 36 W
Efficiency 80.5%
NF C 71-121: 0.73 H + 0.07 T
Candela Distribution
Candela Distribution
0-180 90-270
0-180 90-270
0
195
195
0
185
5
195
194
5
185
10
192
192
90°
10
182
15
187
192
75°
15
20
181
193
25
173
194
60°
30
163
194
45°
35
152
193
40
138
45
124
50
108
182
55
91
176
60
73
163
65
55
70
37
Degrees
2 x 58 W
Efficiency 76.9%
NF C 71-121: 0.70 H + 0.07 T
Candela Distribution
0-180 90-270
185
0
173
184
5
172
Degrees
173
173
Degrees
182
90°
10
170
171
90°
178
181
75°
15
166
169
75°
20
172
183
20
161
172
25
164
183
25
154
172
30
154
183
30
145
172
35
143
183
35
135
171
192
40
131
183
40
123
172
191
45
117
179
45
111
170
50
102
173
50
97
165
55
85
166
55
82
157
60
68
155
60
66
148
150
65
51
145
65
50
139
145
70
35
141
70
34
133
30°
0°
15°
60°
45°
30°
0°
15°
60°
45°
30°
0°
15°
Lighting
Lighting: Enclosed and Gasketed — Area — Fluorescent
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
1105
RigMaster™ Metallic Fluorescent Luminaires
For Hazardous and Adverse Locations
Suitable for Use in Wet Locations. 32 W, 40 W and 60 W Two-Lamp Fixtures.
Class I, Division 2, Groups A, B, C, D
NEMA Type 4X
Marine Type Electric Fixture Non-Recessed
Outside Type (Salt Water) ①②
Applications
• Enclosed and gasketed fixtures for use where vapors, moisture,
dirt or corrosive atmospheres are encountered.
• For use in hazardous locations defined by the NEC as Class
I, Division 2. Groups A, B, C & D; Marine Type Electric Fixture
Non-Recessed Outside Type (Salt Water); UL1598A; and
Type 4X.
• For use in locations where a high degree of corrosion resistance
is required.
• For indoor/outdoor use where protection against dirt, water and
moisture is necessary.
• Typical applications include:
— Oil drilling rigs
— Marine loading terminals
— Processing plants
— Pipeline pumping stations
— Water treatment plants
— Lubrication pits
RM2232BUSW
Illustrated Feature
Lighting: Enclosed and Gasketed — Area — Fluorescent
Lighting
Features
• Choice of mountings: end brackets, swivel brackets and straight
brackets.
• Thick 1/8” clear acrylic lens protects against possible broken
glass from lamps.
• RigMaster fixtures are supplied with the following ballast
options:
— Class P low energy (E) ballasts, equipped with an automatic
thermally-activated protective device. They offer protection
against excessive voltage, internal ballast short circuiting,
inadequate lamp maintenance and improper fixture
application.
— 220- and 240-volt options in both 50 and 60 Hz.
• High-temperature nickel-cadmium battery has a life expectancy
of 7 to 10 years.
• Battery charger indicator light and test switch are mounted
inside the enclosure and visible through the clear lens.
• Heavy-duty telescoping lampholders.
• Fixtures are shipped complete with lamps.
• Swivel End Mount fixture comes standard with eyebolt on fixture
end for connecting safety cable.
• Swivel Center Mount and Straight Center Mount fixtures come
standard with cast mounts on fixture end for connecting safety
cable.
Four plated steel latches on each side of door assure
integrity of fixture for areas as classified.
Certifications and Compliances
• UL Standard: UL 1598, UL 844, UL 924
• UL Listed: E10794
Standard Materials
•
•
•
•
•
Reflector housings: extruded aluminum
Door frame: 1/8” extruded aluminum
Door clamps: heavy-duty plated spring steel
Lampholders: white urea plastic
Gasket: neoprene
Options
• Individually fused ballast: suffix –F.
• Emergency battery pack: suffix –EL ①.
• Emergency Battery Pack capability in moments of power
interruption. Luminaire automatically switches to emergency
mode, keeping one lamp illuminated for a minimum of 90
minutes. When AC power is restored, battery automatically
recharges in 24 hours. Initial light output is 600-700 lumens.
① Fixtures with emergency ballast are not recommended where the ambient temperature may fall below 32 °F/0 °C for extended periods.
② Does not apply to fixtures with fusing.
1106
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
RigMaster™ Metallic Fluorescent Luminaires
For Hazardous and Adverse Locations
Suitable for Use in Wet Locations. 32 W, 40 W and 60 W Two-Lamp Fixtures.
Class I, Division 2, Groups A, B, C, D
NEMA Type 4X
Marine Type Electric Fixture Non-Recessed
Outside Type (Salt Water) ①②
Order using catalog numbering guide below or select catalog number from tables on following pages.
Catalog Numbering Guide For RigMaster Metallic Fluorescent Lighting Fixtures
RM
2
2
Series:
RM - RigMaster
Metallic
40
12
SS
Lamp Type:
32 - 32 W, T8
(Electronic)
40 - 40 W, (Electronic)
60 - 60 W, T12, HO
800 MA (48) ⑤
Hazardous Rating:
Class I, Division 2
CB
EL
Mounting:
CB- End
SW- Swivel
ST- Fixed
Options:
EL- Emergency
Battery Pack ③
F- Fuse
Voltage ④:
12 - 120 V (40 W, T12)
27 - 277 V (40 W, T12)
BU - 120-277 V, 50/60 Hz
(32 W, T8; 60 W, T12)
Number of Lamps:
2 - Two Lamps
Ballast Type:
SS- Solid State (40W, T12,
Electronic) Only
Lamp
Lighting
Thermal Performance RigMaster Fixtures
Quantity
Watt
Type
Ambient Temp
(°F/°C)
“T”
Numbers
Hazardous
Classification
RM2232
2
32
265MA-RS
104/40
T-4
Class I, Division 2, Groups A, B, C, D
RM2240
2
40
430MA-RS
104/40
T-4
Class I, Division 2, Groups A, B, C, D
RM2260
2
60
800MA-HO
104/40
T-4
Class I, Division 2, Groups A, B, C, D
① Fixtures with emergency ballast are not recommended where the ambient temperature may fall below 32 °F/0 °C for extended periods.
② Does not apply to fixtures with fusing.
③ For 50 Hz with Emergency Battery Pack, consult factory for certification.
④ BU for 32 W, T8 and 60 W, T12 only. Voltage must be specified for 40 W, T12.
⑤ CW suffix not needed for 60 W since -20 °F/-28 °C starting provided as a standard.
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
1107
Lighting: Enclosed and Gasketed — Area — Fluorescent
Fixture
RigMaster™ Metallic Fluorescent Luminaires
For Hazardous and Adverse Locations
Suitable for Use in Wet Locations. 32 W, 40 W and 60 W Two-Lamp Fixtures.
Class I, Division 2, Groups A, B, C, D
NEMA Type 4X
Marine Type Electric Fixture Non-Recessed
Outside Type (Salt Water) ①②
Swivel End Bracket
Swivel Center Bracket
Straight Center Bracket
No. of
Lamps ③
Lamp
Wattage
Lamp
Type
Volts
Bracket
Type
Catalog
Number
2
32
T8
120-277 V, 50/60 Hz
end
RM2232BUCB
2
40
T12
120 V, 60 Hz
end
RM224012SSCB
2
40
T12
277 V, 60 Hz
end
RM224027SSCB
2
60
T12
120-277 V, 50/60 Hz
end
RM2260BUCB
2
32
T8
120-277 V, 50/60 Hz
swivel
RM2232BUSW
2
40
T12
120 V, 60 Hz
swivel
RM224012SSSW
2
40
T12
277 V, 60 Hz
swivel
RM224027SSSW
2
60
T12
120-277 V, 50/60 Hz
swivel
RM2260BUSW
2
32
T8
120-277 V, 50/60 Hz
straight
RM2232BUST
2
40
T12
120 V, 60 Hz
straight
RM224012SSST
2
40
T12
277 V, 60 Hz
straight
RM224027SSST
2
60
T12
120-277 V, 50/60 Hz
straight
RM2260BUST
Replacement Parts
Lighting
Description
Catalog Number
Lens
Lens and Frame Assembly
RIGLENS
Straight Bracket
RM3002SEM
Angle Bracket
RM3002AEM
Swivel Bracket
RMBMSW
Back-Straight Bracket
RMBMST
60 W Spring Loaded
RM60SRS
60 W Fixed Replacement
RM60FRS
32 W Replacement
RM32RS
Lighting: Enclosed and Gasketed — Area — Fluorescent
Mounting Brackets
Sockets
Mounting Accessories — Safety Cable
Galvanized Steel Cable
Catalog Number
Stainless Steel Cable
Catalog Number
3 ft/0.9 m
RMSC3GASL
3 ft/0.9 m
RMSC3STSL
4 ft/1.2 m
RMSC4GASL
4 ft/1.2 m
RMSC4STSL
Connecting Safety Cable
Swivel Center Mount and Straight Center
Mount fixture comes standard with cast
mounts on fixture end for connecting
safety cable.
Swivel End Mount fixture comes standard with
eyebolt on fixture end for connecting safety
cable.
① Fixtures with emergency ballast are not recommended where the ambient temperature may fall below 32 °F/0 °C for extended periods.
② Does not apply to fixtures with fusing.
③ Fixtures shipped complete with lamps.
1108
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
RigMaster™ Metallic Fluorescent Luminaire Dimensions
For Hazardous and Adverse Locations
Suitable for Use in Wet Locations. 32 W, 40 W and 60 W Two-Lamp Fixtures.
End Bracket Mounting
.8
01
.25
3
"/1
51
8.10"/
205.7 mm
mm
m
m
.8
93
11 o C
/
"
.0 C t
47
8.10"/205.7 mm
5.42"/137.7 mm
Swivel Bracket Mounting
2.00"/50.8 mm
"/
.50 m
12
m
.5
7
31
Ø 0.28"/
7.0 mm
Lighting
9.75"/
247.7 mm
10.35"/
262.9 mm
Lighting: Enclosed and Gasketed — Area — Fluorescent
17.6"/447.0 mm
Straight Bracket Mounting
/
.0"
11 .4 mm
9
27
6.75"/
171.5 mm
Fixture Bracket Type
Weight in Lbs/Kgs
End
35/15.9
Swivel
35/15.9
Straight
35/15.9
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
1109
RigMaster™ Metallic Fluorescent Luminaire Photometrics
For Hazardous and Adverse Locations
Suitable for Use in Wet Locations. 32 W, 40 W and 60 W Two-Lamp Fixtures.
CATALOG NUMBER: RM2232BU
Candela Distribution
25 1106 1110 1109 1110 1106 512
Luminaire: Class I, Division 2 fluorescent fixture with glass lens (4 foot, T-8. 32 Watt) tested at
120 V
Lamps: Two Phillips 32 W, 4-foot F32T8/TL741fluorescents
Ballast: Advance T-8, 32 Watt, catalog number ICN-2P32-SC 50/60 Hz, Instant Start, 120-277 V
Ambient Temperature: 24 °C/75 °F
Mounting: With Bracket
Based on: 2,850 Lumens per Lamp
TOTAL LUMINAIRE EFFICIENCY = 57.6%
0.0
22.5 45.0 67.5 90.0 Flux
0 1234 1234 1234 1234 1234
5 1234 1228 1227 1228 1224 117
15 1183 1187 1185 1187 1183 335
35
984 990 996 990 984 620
45
813 823 830 823 813 634
CIE Type – Direct
55
612 619 614 619 612 550
Plane:
65
364 375 381 375 364 368
75
124 126 112 126 124 133
85
9
7
7
7
90
1
1
1
1
9
0 1132 1132 1132 1132 1132
Lighting
5 1124 1128 1126 1128 1124 107
Lighting: Enclosed and Gasketed — Area — Fluorescent
% FIXT.
90˚
0- 30
964
16.9
29.4
Spacing Criteria:
1.3
1.3
0- 40
1584
27.8
48.3
Shielding Angles:
1.0
0.0
0- 60
2767
48.6
84.3
0- 90
3281
57.6
100.0
90-180
0
0.0
0.0
0-180
3281
57.6
100.0
CATALOG NUMBER: RM2232BU
22.5 45.0 67.5 90.0 Flux
15 1085 1089 1090 1089 1085 308
25 1003 1010 1011 1010 1003 465
Luminaire: Class I, Division 2 fluorescent fixture with glass lens (4 foot, T-12. 34 Watt) tested at
120 V
Lamps: 2 Philips 34 Watt (4 foot, T-12) F4OCW/RS/EW
Ballast: Advance T-12, 34 Watt, catalog number REL-2S40-SC 50/60 Hz, Instant Start, 120 V
Ambient Temperature: 24 °C/75 °F
Mounting: With Bracket
Based on: 2,650 Lumens per Lamp
35
882 889 888 889 882 555
45
726 730 726 730 726 561
CIE Type – Direct
55
535 535 533 535 535 477
Plane:
65
322 316 311 316 322 314
75
121 112 104 112 121 121
85
9
7
6
7
9
90
0
0
0
0
0
TOTAL LUMINAIRE EFFICIENCY = 55.1%
ZONAL LUMEN SUMMARY
ZONE LUMENS % LAMP
Spacing Criteria:
% FIXT.
0˚
90˚
0- 30
880
16.6
30.1
1.2
1.2
0- 40
1435
27.1
49.2
11
Candela Distribution
0.0
ZONE LUMENS % LAMP
0˚
12
Candela Distribution
0.0
ZONAL LUMEN SUMMARY
0- 60
2473
46.7
84.7
0- 90
2919
55.1
100.0
90-180
0
0.0
0.0
0-180
2919
55.1
100.0
CATALOG NUMBER: RM2260BU
22.5 45.0 67.5 90.0 Flux
25 1100 1108 1111 1108 1100 511
Luminaire: Class I, Division 2 fluorescent fixture with glass lens (4 foot, T-12. 60 Watt) tested
Lamps: 2 Philips 60 Watt (4 foot, T-12) F48T12CWHO ALTO
Ballast: Advance T-12, 60 Watt, catalog number VEL-2S110
Ambient Temperature: 24 °C/75 °F
Mounting: With Bracket
Based on: 4,050 Lumens per Lamp
35
TOTAL LUMINAIRE EFFICIENCY = 39.6%
0 1237 1237 1237 1237 1237
5 1227 1231 1229 1231 1227 117
15 1188 1194 1193 1194 1188 337
968 977 976 977 968 610
45
800 806 805 806 800 619
CIE Type – Direct
55
591 593 594 593 591 529
Plane:
65
351 352 351 352 351 347
Spacing Criteria:
75
122 116 106 116 122 127
85
10
8
6
8
10
90
0
0
0
0
0
1110
12
ZONAL LUMEN SUMMARY
ZONE LUMENS % LAMP
0˚
90˚
1.2
1.2
0- 30
965
11.9
% FIXT.
30.1
0- 40
1574
19.4
49.1
0- 60
2722
33.6
84.8
100.0
0- 90
3208
39.6
90-180
0
0.0
0.0
0-180
3208
39.6
100.0
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
RigMaster™ 304 Stainless Steel Fluorescent Luminaires V
CSA Certification Only. Enclosed and Gasketed. For Hazardous and Adverse Locations
Suitable for use in Wet or Marine (Salt Water) Locations. 32 W, 40 W and 60 W Two-Lamp Fixtures.
Class I, Division 2, Groups A, B, C, D
Class II, Division 1 and 2, Groups E, F, G
Class III
CSA Enclosure 3
Applications
• Appleton Rigmaster is designed for the requirements of the oil
drilling industry.
• For use on seashore, offshore or land based drilling rigs.
• Suitable for industrial applications requiring a highly corrosionresistant fluorescent fixture.
• Approved for outdoor use.
• Ideal for shipboard use. (Salt water environment).
• For use in high vibration installations.
• Can be installed to illuminate work areas, stairways and ladders,
pumps and instrument panels, chemical plants and refineries or
for shipboard deck lighting.
Features
Standard Materials
• Fixture body, snap clips, hardware, lens frame: 304 stainless
steel
• Mounting brackets, CG connectors, reflector: copperfree (4/10
of 1% max.) aluminum
Standard Finishes
• All components have a natural finish
Options
• Emergency battery, operates lamps at 60% for 90 minutes
during power outages, suffix -E.
• Fabricated from 316 stainless steel, suffix -316.
• 60 Watt high output ballast available (-20 °F/-29 °C starting
temperature).
• Lens: tempered glass, suffix -GN.
Compliances
• CSA Standard: C22.2 No. 250, C22.2 No. 137
• CSA Certified: 025428
2
4
Series:
ARM - RigMaster
Stainless Steel
A
BU
GN
Cable Entry
Jacket Range:
A - .312”to .437”
B - .375” to .500”
C - .500" to .625"
Number of Lamps:
2 - Two Lamps
Voltage:
BU - 120-277 V 50/60 Hz
A5 - 347 V 60 Hz
Lamp Type: ①
32 - 32 W, T8 (Electronic)
40 - 40 W, T12 (Rapid Start)
60 - 60 W, T12 (High Output)
Factory Installed Options:
EL- Emergency Back-up Battery
316 - 316 Stainless Steel
GN - Tempered Glass Lens
① Lamps not furnished with fixture.
V CSA Certification Only.
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
1111
Lighting: Enclosed and Gasketed — Area — Fluorescent
Order using catalog numbering guide below or select catalog number from tables on following pages.
Catalog Numbering Guide For RigMaster Stainless Steel Fluorescent Lighting Fixtures — Bracket Mounted
ARM
Lighting
• Corrosion-resistant durable seam welded 304 stainless steel
construction.
• Vibration resistant – spring loaded sockets hold lamps securely
with maximum shock and vibration protection.
• Positive seal lens assembly provides a secure gasketed seal
around the lens. Lexan, impact resistant lens is standard.
• CG series watertight cord connectors grip the cable securely at
the point of entrance to prevent insulation wear and strain on
connections made within the enclosure. CG connectors seal out
oil, water and other harmful atmospheres containing moisture to
keep the enclosure clean and dry.
• Stainless steel snap action clips permit relamping without tools.
Three clips serve as hinges allowing unobstructed access to the
fixture interior.
• The highly polished finished reflector has excellent light
distribution and high efficiency.
• Access to the ballast and wiring chamber is quick and easy,
requiring the removal of two screws.
• Rigmasters are provided with feed-thru wiring, eliminating the
need for a junction box.
RigMaster™ 304 Stainless Steel Fluorescent Luminaires V
CSA Certification Only. Enclosed and Gasketed. For Hazardous and Adverse Locations
Suitable for use in Wet or Marine (Salt Water) Locations. 32 W, 40 W and 60 W Two-Lamp Fixtures.
Class I, Division 2, Groups A, B, C, D
Class II, Division 1 and 2, Groups E, F, G
Class III
CSA Enclosure 3
No. of
Lamps ①
Lamp
Wattage
Lamp
Type
Volts
Operating
Amps
Input
Watts
Cable
Range
Catalog
Number
59 - 55
.312-.437
ARM232ABU
Rapid Start — 48” — T8 — Minimum Starting Temperature 0 °F/-18 °C
2
32
T8
120-277 V
0.49 - 0.19
2
32
T8
347 V
0.21
62
.312-.437
ARM232AA5
2
32
T8
120-277 V
0.49 - 0.19
59 - 55
.375-.500
ARM232BBU
2
32
T8
347 V
0.21
62
.375-.500
ARM232BA5
2
32
T8
120-277 V
0.49 - 0.19
59 - 55
.500-.625
ARM232CBU
2
32
T8
347 V
0.21
62
.500-.625
ARM232CA5
Rapid Start — 48” — F48T12/CW — Minimum Starting Temperature -22 °F/-30 °C
2
40
T12
120-277 V
0.7 - 0.26
84 - 70
.312-.437
ARM240ABU
2
40
T12
347 V
0.28
96
.312-.437
ARM240AA5
2
40
T12
120-277 V
0.7 - 0.26
84 - 70
.375-.500
ARM240BBU
2
40
T12
347 V
0.28
96
.375-.500
ARM240BA5
2
40
T12
120-277 V
0.7 - 0.26
84 - 70
.500-.625
ARM240CBU
2
40
T12
347 V
0.28
96
.500-.625
ARM240CA5
122 - 108
.312-.437
ARM260ABU
Lighting: Enclosed and Gasketed — Area — Fluorescent
Lighting
Rapid Start — 48” — 800 mA — F48T12/CW/HO — Minimum Starting Temperature -22 °F/-30 °C
2
60
T12
120-277 V
1.05 - 0.40
2
60
T12
347 V
0.45
144
.312-.437
ARM260AA5
2
60
T12
120-277 V
1.05 - 0.40
122 - 108
.375-.500
ARM260BBU
2
60
T12
347 V
0.45
144
.375-.500
ARM260BA5
2
60
T12
120-277 V
1.05 - 0.40
122 - 108
.500-.625
ARM260CBU
2
60
T12
347 V
0.45
144
.500-.625
ARM260CA5
Dimensions in Inches/Millimeters
① Lamps not furnished with fixture.
V CSA Certification Only.
1112
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
VRS™ and DRS™ Fluorescent Luminaires
Enclosed and Gasketed. Suitable for Use in Wet Locations
32 W, 40 W and 60 W Two- and Three-Lamp Fixtures.
VRS:
Class I, Division 2, Groups A, B, C, D
DRS:
Class II, Division 1 and 2, Groups F, G
Class III
Applications
• VRS
— Enclosed and gasketed fixtures for use where vapors,
moisture, dirt or corrosive atmospheres are encountered.
— Corrosion-resistant polyester powder coating protects
against corrosive atmospheres.
• DRS
— Dust-ignitionproof fixtures for use where ignitable amounts
of dust are present from handling such products as grain,
flour, sugar, starch and textiles.
— Suitable for use in Class II and III, Division 1, classified areas.
— Corrosion-resistant finish prolongs fixture life and retains
fixtures reflectivity longer.
Features
VRS Enclosed and Gasketed DRS Dust-Ignition Proof
Illustrated Features
Lighting
Three plated steel latches on each side of door
assure integrity of fixture for areas as classified.
Lighting: Enclosed and Gasketed — Area — Fluorescent
• Choice of mountings: pendant and feed thru are standard,
angle bars for chain suspension, or angle brackets (up to 45°)
for wall or ceiling mounting.
• Thick 1/4” clear tempered glass lens protects against possible
broken glass from lamps.
• VRS and DRS fixtures are supplied with the following
ballast options:
— Class P low energy (E) ballasts, equipped with an automatic
thermally activated protective device. They offer protection
against excessive voltage, internal ballast short circuiting,
inadequate lamp maintenance and improper fixture
application
• High-temperature nickel cadmium battery has a life expectancy
of 7 to 10 years.
• Battery charger indicator light and test switch are mounted
inside the enclosure and visible through the clear lens.
• Heavy duty telescoping lampholders.
• Low operating cost provides more lumens per Watt than
incandescent.
• Easy cleaning one-piece, seamless welded construction virtually
eliminates dust and moisture accumulation.
Standard Materials
•
•
•
•
•
•
Reflector housings: 20-gauge steel
Door frame: 16 gauge steel with clear glass
Door clamps: heavy-duty plated spring steel
Suspension hubs: 1/2” die-cast aluminum
Lampholders: white urea plastic
Gaskets: VRS – neoprene; DRS – fiberglass
Standard Finishes
• Reflector housings: VRS – white polyester powder coating; DRS
– white polyester powder coating
• Door frame: zinc electroplate
• Door clamps, suspension hubs and lampholders: natural finish
Options
• Individually fused ballast. Suffix -F.
• Emergency battery pack, Suffix -EL ➊.
• Emergency battery pack capability in moments of power
interruption. Luminaire automatically switches to emergency
mode, keeping one lamp illuminated for a minimum of 90
minutes. When AC power is restored, battery automatically
recharges in 24 hours. Initial light output is 600-700 lumens.
Pan mounted ballast and sockets with safety
chain provide quick, safe maintenance.
Certifications and Compliances
• UL Standard: UL 1598, UL 844
• UL Listed: E10794
➊ Fixtures with emergency ballast are not recommended where the ambient temperature may fall below 32 °F/0 °C for extended periods.
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
1113
VRS™ and DRS™ Fluorescent Luminaires
Enclosed and Gasketed. Suitable for Use in Wet Locations
32 W, 40 W and 60 W Two- and Three-Lamp Fixtures.
VRS:
Class I, Division 2, Groups A, B, C, D
DRS:
Class II, Division 1 and 2, Groups F, G
Class III
Order using catalog numbering guide below or select catalog number from tables on following pages.
Catalog Numbering Guide For VRS And DRS Non-Metallic Fluorescent Lighting Fixtures
VRS
2
40
Series:
VRS - Vaportight
DRS - Dust-Ignitionproof
BU
Lamp Type:
32 - 32 W,T8 (Electronic)
40 - 40 W, (Electronic)
60 - 60 W, T12, HO 800 MA (48)
Number of Lamps
2 - 2 Lamps
3 - 3 Lamps
EL
Options:
EL - Emergency Battery Pack
F - Fuse
Voltage:
BU - 120-277 V, 50/60 Hz
347 - 347 V 60 Hz V
Technical Data: Thermal Performance of VRS and DRS Fixtures
Lighting: Enclosed and Gasketed — Area — Fluorescent
Lighting
Lamp
Fixture
Quantity
Watt
Type
Ambient
Temp °F/°C
“T”
Numbers
Hazardous
Classification
VRS232
2
32
265MA-RS
104/40
T-4A
Class I, Division 2, Groups A,B,C,D
VRS332
3
32
265MA-RS
104/40
T-4A
Class I, Division 2, Groups A,B,C,D
VRS240
2
40
430MA-RS
104/40
T-4A
Class I, Division 2, Groups A,B,C,D
VRS340
3
40
430MA-RS
104/40
T-4A
Class I, Division 2, Groups A,B,C,D
VRS260
2
60
800MA-HO
77/25
T-3C
Class I, Division 2, Groups A,B,C,D
DRS232
2
32
265MA-RS
77/25
T-6
Class II, Division 1 & 2 Groups F,G
DRS332
3
32
265MA-RS
77/25
T-6
Class II, Division 1 & 2 Groups F,G
DRS240
2
40
430MA-RS
77/25
T-4
Class II, Division 1 & 2 Groups F,G
DRS340
3
40
430MA-RS
77/25
T-6
Class II, Division 1 & 2 Groups F,G
DRS260
2
60
800MA-HO
77/25
T-6
Class II, Division 1 & 2 Groups F,G
Vaportight Adjustable Hanger or Aligner – Iron Outlet Plugs
• Suitable for use in locations where equipment is exposed to the
deteriorating effects of non-combustible atmospheres containing
corrosive fumes, vapors, dust, smoke and/or moisture.
• Range of adjustment is 45°. Two-piece ball type cast iron body; gasket
sealed at the adjustable ball joint. Maximum overall length is 53-5/8
inches. Finish is baked white paint over electroplating.
• These iron plugs are for closing tapped outlets in explosion-proof
boxes. Plugs are electroplated and finished in baked aluminum paint.
A socket head is provided for square wrenches.
V CSA Certification Only.
1114
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
VRS™ and DRS™ Fluorescent Luminaires
Enclosed and Gasketed. Suitable for Use in Wet Locations
32 W, 40 W and 60 W Two- and Three-Lamp Fixtures.
VRS:
Class I, Division 2, Groups A, B, C, D
Number of Lamps ➋
Lamp Watts
DRS:
Class II, Division 1 and 2, Groups F, G
Class III
Lamp Type
Unput Volts
Freq. (Hz)
Ballast Type
Catalog Number
VRS 32 W, 40 W and 60 W Fixtures Furnished with 1/4” Clear Tempered Glass Lens ➊
2
32
T8
120-277
50/60
Electronic
VRS232BU
2
40
T12
120-277
50/60
Electronic
VRS240BU
2
60
T12
120-277
50/60
Electronic
VRS260BU
3
32
T8
120-277
50/60
Electronic
VRS332BU
3
40
T12
120-277
50/60
Electronic
VRS340BU
DRS 32 W, 40 W and 60 W Fixtures Furnished with 1/4” Clear Tempered Glass Lens
2
32
T8
120-277
50/60
Electronic
DRS232BU
2
40
T12
120-277
50/60
Electronic
DRS240BU
2
60
T12
120-277
50/60
Electronic
DRS260BU
3
32
T8
120-277
50/60
Electronic
DRS332BU
3
40
T12
120-277
50/60
Electronic
DRS340BU
Lighting
Lighting: Enclosed and Gasketed — Area — Fluorescent
OPTIONS: Add suffix -F for individually fused ballast. Add suffix -EL for emergency battery pack. (For 50Hz with -EL suffix, consult factory for certifications.)
➊ Consult factory for clear high-impact acrylic lens. UL Listed for Class I, Division 2, Groups. A, B, C, D; suitable for use in locations exposed to moisture or noncombustible gases.
➋ Lamps not furnished with fixture.
➌ Low temperature ballast (-20 °F/-29 °C starting) provided as standard.
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
1115
VRS™ and DRS™ Fluorescent Luminaires
Enclosed and Gasketed. Suitable for Use in Wet Locations
32 W, 40 W and 60 W Two- and Three-Lamp Fixtures.
Description
Catalog Number
45° Adjustable Brackets
Two “L-type” brackets with gaskets – adjustable to 45°
in 5° increments for “custom” illumination spread.
DRKHN
Two “L-type” brackets with gaskets for wall or ceiling
mounting – provides wide-spread illumination.
DRAGN
Two heavy-duty bars with holes for chain suspension of
fixtures.
DRCXN
Lens and door frame
VRSLENS
Lens and door frame
DRSLENS
32- and 40 Watt Fixed-end lampholder (Med. Bi-pin)
VRSDRS40SS0C
32- and 40 Watt Plunger-end lampholder (Med. Bi-pin)
VRSDRS40CS0C
60 Watt Fixed-end lampholder (High Output)
VRSDRS60SS0C
60 Watt Plunger-end lampholder (High Output)
VRSDRS60CS0C
45° Fixed Mounting Brackets
Lighting
Angle Bars
Lighting: Enclosed and Gasketed — Area — Fluorescent
Lens and Door Frame
Sockets – Lampholders
Plunger Type
Fixed Type
* Each lamp has a Fixed and Plunger Lampholder
Hubs
Side and Top suspension hubs
1116
VRSDRSHUB
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
VRS™ and DRS™ Fluorescent Luminaire Photometric Data
Enclosed and Gasketed. Suitable for Use in Wet Locations
32 W, 40 W and 60 W Two- and Three-Lamp Fixtures.
Zone
Lumens
Total Luminaire Efficiency = 73.5%
0-10
145.72
CIE Type – Direct
10-20
421.76
20-30
651.35
30-40
798.47
0-180
1.28
Coefficients of Utilization - Zonal Cavity Method
40-50
824.90
90-270
1.34
Effective Floor Cavity Reflectance 0.20
50-60
701.76
Diagonal
1.44
60-70
498.35
70-80
189.17
80-90
30.32
90-100
0.00
REPORT NUMBER: VRS232
Lamps: Two 32 W Fluorescent Vaportightproof
Spacing
Criteria
Plane
% Ceiling Rcc
% Walls
Zone
70
50
30
10
0
70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0
0 87 87 87 87 85 85 85 85 82 82 82 78 78 78 75 75 75 73
Zonal Lumen Summary
0-30
Rw
80
Lumens % Lamp % Fixture
1 81 77 74 72 79 76 73 71 73 70 68 70 68 66 67 66 64 63
1218.83 21.0
2 74 68 63 59 72 66 62 58 64 60 57 62 58 56 59 57 55 53
28.6
100-110
0.00
0-40
2017.30 34.8
47.3
3 67 60 54 49 65 59 53 49 56 52 48 54 51 47 53 49 46 45
110-120
0.00
0-60
3543.96 61.1
83.2
4 62 53 47 42 60 52 46 42 50 45 41 49 44 41 47 43 40 38
4261.81 73.5
100.0
5 57 47 41 36 55 47 41 36 45 40 36 44 39 35 42 38 35 33
0.0
6 52 43 36 32 51 42 36 31 41 35 31 39 35 31 38 34 31 29
120-130
0.00
0-90
130-140
0.00
90-120
0.00
0.0
0.00
90-130
0.00
0.0
0.0
7 48 39 32 28 47 38 32 28 37 32 28 36 31 27 35 31 27 26
0.00
90-150
0.00
0.0
0.0
8 45 35 29 25 44 35 29 25 34 28 25 33 28 25 32 28 24 23
0.00
0.0
0.0
9 42 32 26 22 41 32 26 22 31 26 22 30 26 22 30 25 22 21
4261.81 73.5
100.0
10 39 30 24 20 39 29 24 20 29 24 20 28 23 20 27 23 20 19
160-170
0.00
90-180
170-180
0.00
180-0
Zone
Lumens
Total Luminaire Efficiency = 70.1%
0-10
126.78
CIE Type – Direct
10-20
367.88
20-30
567.43
30-40
693.10
0-180
1.28
40-50
715.79
90-270
1.32
50-60
620.48
Diagonal
1.42
433.89
163.48
80-90
25.87
90-100
0.00
REPORT NUMBER: VRS240
Lamps: Two 40 W Fluorescent Vaportightproof
Spacing
Criteria
Coefficients of Utilization - Zonal Cavity Method
Effective Floor Cavity Reflectance 0.20
% Ceiling Rcc
% Walls
Zone
70
50
30
10
0
70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0
0 83 83 83 83 81 81 81 81 78 78 78 75 75 75 72 72 72 70
Zonal Lumen Summary
0-30
Rw
80
Lumens % Lamp % Fixture
1 77 74 71 69 75 72 70 67 69 67 65 67 65 63 64 63 61 60
1062.10
2 70 65 60 56 68 63 59 56 61 57 54 59 56 53 57 54 52 51
20.0
28.6
100-110
0.00
0-40
1755.20
33.1
47.3
3 64 57 52 47 62 56 51 47 54 49 46 52 48 45 50 47 44 43
110-120
0.00
0-60
3091.47
58.3
83.2
4 59 51 45 40 57 50 44 40 48 43 39 46 42 39 45 41 38 37
3714.71
70.1
100.0
5 54 45 39 35 53 44 39 34 43 38 34 42 37 34 40 36 33 32
0.00
0.0
0.0
6 50 41 35 30 49 40 34 30 39 34 30 38 33 29 37 32 29 28
120-130
0.00
0-90
130-140
0.00
90-120
140-150
0.00
90-130
0.00
0.0
0.0
7 46 37 31 27 45 36 31 27 35 30 26 34 30 26 33 29 26 25
150-160
0.00
90-150
0.00
0.0
0.0
8 43 34 28 24 42 33 28 24 32 27 23 31 27 23 31 26 23 22
160-170
0.00
90-180
170-180
0.00
180-0
0.00
0.0
0.0
9 40 31 25 21 39 30 25 21 30 25 21 29 24 21 28 24 21 20
3714.71
70.1
100.0
10 38 28 23 19 37 28 23 19 27 23 19 27 22 19 26 22 19 18
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
1117
Lighting: Enclosed and Gasketed — Area — Fluorescent
60-70
70-80
Plane
Lighting
140-150
150-160
DRS™ Fluorescent Luminaire Photometric Data
Enclosed and Gasketed. Suitable for Use in Wet Locations
32 W, 40 W and 60 W Two- and Three-Lamp Fixtures.
Lighting
Zone
Lumens
Total Luminaire Efficiency = 73.5%
0-10
145.72
CIE Type – Direct
10-20
421.76
20-30
651.35
30-40
798.47
0-180
1.28
40-50
824.90
90-270
1.34
50-60
701.76
Diagonal
1.44
60-70
498.35
70-80
189.17
80-90
30.32
90-100
0.00
Spacing
Criteria
Plane
Coefficients of Utilization - Zonal Cavity Method
Effective Floor Cavity Reflectance 0.20
% Ceiling Rcc
% Walls
Zone
70
50
30
10
0
70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0
0 87 87 87 87 85 85 85 85 82 82 82 78 78 78 75 75 75 73
Zonal Lumen Summary
0-30
Rw
80
Lumens % Lamp % Fixture
1 81 77 74 72 79 76 73 71 73 70 68 70 68 66 67 66 64 63
1218.83
2 74 68 63 59 72 66 62 58 64 60 57 62 58 56 59 57 55 53
21.0
28.6
100-110
0.00
0-40
2017.30
34.8
47.3
3 67 60 54 49 65 59 53 49 56 52 48 54 51 47 53 49 46 45
110-120
0.00
0-60
3543.96
61.1
83.2
4 62 53 47 42 60 52 46 42 50 45 41 49 44 41 47 43 40 38
4261.81
73.5
100.0
5 57 47 41 36 55 47 41 36 45 40 36 44 39 35 42 38 35 33
0.00
0.0
0.0
6 52 43 36 32 51 42 36 31 41 35 31 39 35 31 38 34 31 29
120-130
0.00
0-90
130-140
0.00
90-120
140-150
0.00
90-130
0.00
0.0
0.0
7 48 39 32 28 47 38 32 28 37 32 28 36 31 27 35 31 27 26
150-160
0.00
90-150
0.00
0.0
0.0
8 45 35 29 25 44 35 29 25 34 28 25 33 28 25 32 28 24 23
160-170
0.00
90-180
170-180
0.00
180-0
Zone
Lighting: Enclosed and Gasketed — Area — Fluorescent
REPORT NUMBER: DRS232
Lamps: Two 32 W Fluorescent Dust-Ignitionproof
0.00
0.0
0.0
9 42 32 26 22 41 32 26 22 31 26 22 30 26 22 30 25 22 21
4261.81
73.5
100.0
10 39 30 24 20 39 29 24 20 29 24 20 28 23 20 27 23 20 19
Lumens
Total Luminaire Efficiency = 70.1%
0-10
126.78
CIE Type – Direct
10-20
367.88
20-30
567.43
30-40
693.10
0-180
1.28
Coefficients of Utilization - Zonal Cavity Method
40-50
715.79
90-270
1.32
Effective Floor Cavity Reflectance 0.20
50-60
620.48
Diagonal
1.42
60-70
433.89
70-80
163.48
80-90
25.87
90-100
0.00
Plane
REPORT NUMBER: DRS240
Lamps: Two 40 W Fluorescent Dust-Ignitionproof
Spacing
Criteria
% Ceiling Rcc
% Walls Rw
Zone
70
50
30
10
0
0 83 83 83 83 81 81 81 81 78 78 78 75 75 75 72 72 72 70
Zonal Lumen Summary
0-30
80
70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0
Lumens % Lamp % Fixture
1 77 74 71 69 75 72 70 67 69 67 65 67 65 63 64 63 61 60
1062.10
2 70 65 60 56 68 63 59 56 61 57 54 59 56 53 57 54 52 51
20.0
28.6
100-110
0.00
0-40
1755.20
33.1
47.3
3 64 57 52 47 62 56 51 47 54 49 46 52 48 45 50 47 44 43
110-120
0.00
0-60
3091.47
58.3
83.2
4 59 51 45 40 57 50 44 40 48 43 39 46 42 39 45 41 38 37
3714.71
70.1
100.0
5 54 45 39 35 53 44 39 34 43 38 34 42 37 34 40 36 33 32
0.00
0.0
0.0
6 50 41 35 30 49 40 34 30 39 34 30 38 33 29 37 32 29 28
120-130
0.00
0-90
130-140
0.00
90-120
140-150
0.00
90-130
0.00
0.0
0.0
7 46 37 31 27 45 36 31 27 35 30 26 34 30 26 33 29 26 25
150-160
0.00
90-150
0.00
0.0
0.0
8 43 34 28 24 42 33 28 24 32 27 23 31 27 23 31 26 23 22
160-170
0.00
90-180
170-180
0.00
180-0
1118
0.00
0.0
0.0
9 40 31 25 21 39 30 25 21 30 25 21 29 24 21 28 24 21 20
3714.71
70.1
100.0
10 38 28 23 19 37 28 23 19 27 23 19 27 22 19 26 22 19 18
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
RE Series Recessed Fluorescent Luminaires
Standard and Emergency Back-Up. Increased Safety
Zone 1 & 2 – 21 & 22
II 2 GD
ATEX / IECEx
IP66 - IK09/10
Applications
4 x 18 W Surface Mounting
Features
Standard Materials
• Housing and integral frame: one-piece, welded steel
• Safety lens: 0.20"/5 mm thick tempered
• Gasket: Silicone, 4 lips, completely sealed and contained
in the fixture
• Internal reflector: white polycarbonate multi-parabolic
• Cable gland and blanking plug: polyamide
Standard Finishes
2 x 36 W Recessed
Certifications and Compliances
• Gas: Zones 1 and 2
— Conforming to ATEX 94/9/CE: CE 0081 II2 G
— ATEX/IEC Protection: Ex de IIC/ Ex demb IIC (emergency
version)
— T Rating: T6 to T4 (see T Ratings on following page)
• Dust: Zone 22
— Conforming to ATEX 94/9/CE: CE 0081
II2 D
— ATEX/IEC Protection: Ex tD A21
— Surface Temperature: T167 °F /75 °C
• Ambient Temperature: -4 °F/-20 °C Ta 131 °F/55 °C
• CE Declaration of Conformity: 50276
• ATEX Certificate: LCIE 07 ATEX 6104
• IECEx Certificate: IECEx LCI 07.0019
• Index of Protection: IP66
• Impact of Resistance: IK09 or IK10 depending on version
• Ex standards :EN / IEC 60079-0; 60079-1; 60079-7; 60079-18
61241-0; 61241-1
• Product standards: EN / IEC 60598-1; 60598-2-22
• EMC standards: EN / IEC 55015; 61547
• Other standards: EN / IEC 60529 (IP); 62262 (IK)
• Housing and integral frame: white powder epoxy paint
Options
• 316L stainless steel housing and integral frame, natural finish.
• Through wiring.
• White powder epoxy painted steel reflector.
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
1119
Lighting
• One-piece welded steel housing with integral frame to
seal out contaminants.
• Allows recessed mounting in permanent ceilings from
55 mm to 130 mm (2" to 5" approximately).
• Frameless tempered (safety) 5 mm (1/4") thick lens.
Lens secured to housing by internal metallic hinges
and secured with captive 316L stainless steel screws,
allowing for easy lamp replacement and fixture maintenance.
• Positive safety switch and new Ex e battery with
plug-in connector for safety and easy maintenance
in hazardous locations.
• Designed for ease of installation and maintenance.
• Bi-pin G13 lampholder.
• Also available as surface mounting version.
• New ballast:
— EOL (End Of Life) protection in accordance to the latest EN
60079-7 standard
— Multi-tap 110 to 254 Vac/Vdc +/-10% 50/60 Hz
— Two channel standard ballast (if one lamp fails the second
lamp remains in operation)
— Ex e plug-in connector for rapid and error free maintenance
— Self test on 3 hours duration emergency version
— High power factor electronic ballast (>0.95)
• Cable entries:
— Three clearance holes for M20 cable gland supplied with M20
polyamide cable gland (cable dia. 0.26 to 0.57" / 6.5 to 14.5
mm) and M20 polyamide blanking plug as below quantity:
— One M6 earth stud.
Lighting: Enclosed and Gasketed — Area — Recessed Fluorescent
• Designed for flush or surface mounting; most specifically
clean room environments where a seamless smooth ceiling
is mandatory.
• Typical applications include: the food industry, chemical
plants, pharmaceuticals and delicate electronic manufacturing
such as the aerospace industry.
• Ideal for rigorous corrosive environments, involving water,
dust and extreme temperature variations.
• Can be installed in hazardous areas designated as Zone
1, 2, 21 and 22.
RE Series Recessed Fluorescent Luminaires
Standard and Emergency Back-Up. Increased Safety
Zone 1 & 2 – 21 & 22
II 2 GD
ATEX / IECEx
IP66 - IK09/10
Order using catalog numbering guide below or select catalog number from tables on following pages.
Catalog Numbering Guide For FL Non-Metallic Fluorescent Lighting Fixtures
RE
B
1
18
Lighting
Lighting: Enclosed and Gasketed — Area — Recessed Fluorescent
Series:
RE - RE Series
BU
L
Options:
E - 3H Emergency (combined) - Battery
6 V - 4 Ah
E1 - 1 H 30 Emergency (combined)
- Battery 6 V - 7 Ah
E7 - 3H Emergency (combined) Battery 6 V - 7 Ah
N - No switch ③
P - White painted steel internal
reflector ①
S - 316L Stainless steel housing)
Wattage:
18 - 18 Watt
36 - 36 Watt
58 - 58 Watt
Lamp Type:
B - Bi-pin (G13)
E
Voltage:
B3 - 100 to 130 Vac/Vdc
50/60 Hz
BU - 110 to 254 Vac/Vdc
50/60 Hz
BK - 220 to 240 Vac/Vdc
50/60 Hz
Number of Lamps:
1 - Single
2 - Double
3 - Three Lamps
4 - Four Lamps
Termination/Wiring:
L - Loop In/Loop Out
T - Through wired ②
T Ratings
Version
Termination and Wiring
Ambient Temperature
Ceiling Position
Wall Position
104 °F/ 122 °F/ 131 °F/ 104 °F/ 122 °F/ 131 °F/
40 °C
50 °C
55 °C
40 °C
50 °C
55 °C
2 x 18 W ④
T6
T5
T5
T5
T5
T4
2 x 18 W Emergency ④
T5
T4
T4
T5
T5
T4
3 x 18 W
T5
T4
T4
T4
T4
T4
4 x 18 W
T5
T4
T4
T5
T4
T4
2 x 36 W ④
T5
T4
T4
T5
T4
T4
2 x 36 W Emergency ④
T5
T4
T4
T5
T4
T4
3 x 36 W
T4
T4
T4
T4
T4
T4
4 x 36 W
T5
T4
T4
T5
T4
T4
2 x 58 W ④
T4
T4
T4
T4
T4
T4
2 x 58 W Emergency ④
T4
T4
T4
T4
T4
T4
3 x 58 W
T4
T4
T4
T4
T4
4 x 58 W
T4
T4
T4
T4
T4
• Terminal capacity: 0.006 in2/4 mm2 (flexible) or
0.009in2/6 mm2 (solid).
• Loop in/Loop out: One terminal block ⑤
— Standard version:
2 (L) + 2 (N) + 2 (PE)
— Emergency version:
2 (LP) + 2 (L) + 2 (N) + 2 (PE)
• Through wired: Two terminal blocks (one at each
end) ⑤
— Standard version:
2 (L) + 2 (N) + 2 (PE)
1 (L) + 1 (N) + 1 (PE)
— Emergency version:
2 (LP) + 2 (L) + 2 (N) + 2 (PE)
1 (LP) + 1 (L) + 1 (N) + 1 (PE)
T4
Version
Loop
Cable Gland
1
Blanking
Plug
1
Nickel
Plated
Brass
Locknut
3
T4
Through
2
1
3
① As standard for 18 W emergency version and 4 lamp version.
② T/W and Loop in/Loop out - 3 cores (single phase).
③ Only for standard versions.
④ T rating for single lamp version is the same as twin lamp version.
⑤ PE: Earth; N: Neutral. L: Live. LP: Permanent Live for emergency version.
1120
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
RE Series Recessed Fluorescent Luminaires
Standard and Emergency Back-Up. Increased Safety
Zone 1 & 2 – 21 & 22
II 2 GD
ATEX / IECEx
IP66 - IK09/10
Recessed — 110/254 Vac/Vdc 50/60 Hz — Front access — White Painted Steel Housing
Version
Wiring
Reflector
Weight (lbs/kg)
Volume (in3/dm3)
Catalog Number
Standard Version — Bi-pin Lamps (G13)
Loop
Polycarbonate
30.86/14
3905.52/64
REB218BUFL
2 x 18 W
Through
Polycarbonate
30.86/14
3905.52/64
REB218BUFT
4 x 18 W
Loop
White Painted Steel
46.30/21
5675.21/93
REB418BUFLP
4 x 18 W
Through
White Painted Steel
46.30/21
5675.21/93
REB418BUFTP
2 x 36 W
Loop
Polycarbonate
41.89/19
6590.56/108
REB236BUFL
2 x 36 W
Through
Polycarbonate
41.89/19
6590.56/108
REB236BUFT
4 x 36 W
Loop
White Painted Steel
63.93/29
9641.75/158
REB436BUFLP
4 x 36 W
Through
White Painted Steel
63.93/29
9641.75/158
REB436BUFTP
2 x 58 W
Loop
Polycarbonate
48.50/22
7933.09/130
REB258BUFL
2 x 58 W
Through
Polycarbonate
48.50/22
7933.09/130
REB258BUFT
4 x 58 W
Loop
White Painted Steel
70.55/32
11594.51/190
REB458BUFLP
4 x 58 W
Through
White Painted Steel
70.55/32
11594.51/190
REB458BUFTP
3 Hours Emergency Version — Bi-pin Lamps (G13)
2 x 18 W
Loop
Polycarbonate
30.86/14
3905.52/64
REB218BUFLEP
2 x 18 W
Through
Polycarbonate
30.86/14
3905.52/64
REB218BUFTEP
4 x 18 W
Loop
White Painted Steel
46.30/21
5675.21/93
REB418BUFLEP
4 x 18 W
Through
White Painted Steel
46.30/21
5675.21/93
REB418BUFTEP
2 x 36 W
Loop
Polycarbonate
41.89/19
6590.56/108
REB236BUFLE
2 x 36 W
Through
Polycarbonate
41.89/19
6590.56/108
REB236BUFTE
4 x 36 W
Loop
White Painted Steel
63.93/29
9641.75/158
REB436BUFLEP
4 x 36 W
Through
White Painted Steel
63.93/29
9641.75/158
REB436BUFTEP
2 x 58 W
Loop
Polycarbonate
48.50/22
7933.09/130
REB258BUFLE
2 x 58 W
Through
Polycarbonate
48.50/22
7933.09/130
REB258BUFTE
4 x 58 W
Loop
White Painted Steel
70.55/32
11594.51/190
REB458BUFLEP
4 x 58 W
Through
White Painted Steel
70.55/32
11594.51/190
REB458BUFTEP
Lighting
For non-recessed lighting, please replace letter “F” with letter “M” as per Catalog number logic. Example: REB218BUFL becomes REB218BUML.
Accessories
Description
Weight (lbs/kg)
Catalog Number
Fixing Brackets - Set of four.
Zinc plated steel
1.32/0.60
REFBST
316 stainless steel
1.32/0.60
REFBSS
Ceiling Mounting Brackets - Set of two
Zinc plated steel
4.41/2.00
RECMST
316 stainless steel
4.41/2.00
RECMSS
Zinc plated steel
0.55/0.25
REEBST
316 stainless steel
0.55/0.25
REEBSS
M8 Eye Bolts - Set of four
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
Lighting: Enclosed and Gasketed — Area — Recessed Fluorescent
2 x 18 W
1121
RE Series Recessed Fluorescent Luminaires
Standard and Emergency Back-Up. Increased Safety
Zone 1 & 2 – 21 & 22
II 2 GD
ATEX / IECEx
IP66 - IK09/10
Wiring Diagram
Emergency Function Diagram
Two Lamp Version
Mains
PE
N
L
Mains
Lighting: Enclosed and Gasketed — Area — Recessed Fluorescent
Lighting
Switch
Lighting Switch ON
Lighting Switch OFF
Lighting Switch ON
Lighting Switch OFF
ON
L’
U
N
PE
OFF
Standard Fluorescent
Lighting Fixture
Three Lamp Version
Mains
ON
U’
U
N
PE
Emergency Fluorescent
Lighting Fixture
OFF
LED Status
Color
Lighting
Green
Indication
LED glows
Function
Batteries are connected
LED blinks
Batteries are charged
Red
LED blinks
Batteries are not connected or defect
Yellow
LED blinks
Batteries are charging and discharging during automatic cycle
Emergency Light Duration
Version
Battery Capacity
Duration
Light Output
2 x 18 W
4 Ah – 6 V
3 hours
45%
4 Ah – 6 V
3 hours
15%
7 Ah – 6 V
3 hours
25%
4 Ah – 6 V
3 hours
9%
7 Ah – 6 V
3 hours
15%
2 x 36 W
2 x 58 W
1122
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
RE Series Recessed Fluorescent Luminaire Dimensions
Standard and Emergency Back-Up. Increased Safety
Zone 1 & 2 – 21 & 22
II 2 GD
ATEX / IECEx
IP66 - IK09/10
Dimensions in Inches/Millimeters
Recessed
Surface Mounting
A
A
C
D
0.08”/
2.0 mm
5.30”/
134.5 mm
5.23”/
132.5 mm
Lighting: Enclosed and Gasketed — Area — Recessed Fluorescent
B
B
C
D
E
E
4 x Ø 0.33”/8.5 mm
F
4 x Ø 0.33”/8.5 mm
F
Ceiling Cut-out
G
H
A
B
C
D
E
F
G
H
32.52/826
12.60/320
10.63/270
30.55/776
15.35/390
7.24/184
30.94/786
11.02/280
18 W (4 lamps)
32.52/826
19.29/490
17.32/440
30.55/776
15.35/390
13.94/354
30.94/786
17.72/450
36 W (1, 2, 3 lamps)
56.54/1436
12.60/320
10.63/270
54.57/1386
39.37/1000
7.24/184
54.96/1396
11.02/280
36 W (4 lamps)
56.54/1436
19.29/490
17.32/440
54.57/1386
39.37/1000
13.94/354
54.96/1396
17.72/450
58 W (1, 2, 3 lamps)
68.35/1736
12.60/320
10.63/270
66.38/1686
51.18/1300
7.24/184
66.77/1696
11.02/280
58 W (4 lamps)
68.35/1736
19.29/490
17.32/440
66.38/1686
51.18/1300
13.94/354
66.77/1696
17.72/450
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
1123
Lighting
Versions
18 W (1, 2, 3 lamps)
RE Series Recessed Fluorescent Luminaire Photometric Data
Standard and Emergency Back-Up. Increased Safety
Zone 1 & 2 – 21 & 22
II 2 GD
ATEX / IECEx
IP66 - IK09/10
Longitudinal
Transverse
Polar curves for a 1000 lm flux, according to NF C 71-120
Luminaire symbol according to NF C 71-121
Lighting
Lighting: Enclosed and Gasketed — Area — Recessed Fluorescent
1 x 18 W
Efficiency 67.1%
NF C 71-121: 0.67 E
2 x 18 W
Efficiency 62%
NF C 71-121: 0.62 E
3 x 18 W
Efficiency 61.2%
NF C 71-121: 0.61 E
Candela Distribution
Candela Distribution
0-180 90-270
0-180 90-270
Candela Distribution
0-180 90-270
0
209
209
0
205
205
0
201
5
Degrees
208
208
5
Degrees 203
204
5
Degrees 201
200
201
10
205
208
90°
10
202
203
90°
10
197
201
90°
15
201
207
75°
15
197
202
75°
15
193
200
75°
20
194
205
20
191
201
60°
20
187
197
60°
25
186
203
25
182
201
25
179
195
30
176
201
30
173
200
30
169
192
35
164
197
35
161
192
35
158
189
40
151
192
40
148
183
40
145
181
45
136
185
45
133
177
45
131
170
50
120
177
50
117
173
50
115
155
55
102
164
55
99
168
55
98
132
60
83
141
60
80
168
60
80
107
65
63
115
65
61
163
65
61
80
70
43
77
70
41
154
70
41
53
60°
45°
30°
0°
15°
2 x 18 W
Efficiency 60.5%
NF C 71-121: 0.60 F
0
5
10
15
20
25
30
35
40
45
50
55
60
65
70
30°
0°
15°
45°
30°
0°
15°
4 x 18 W
Efficiency 63.7%
NF C 71-121: 0.63 E
Candela Distribution
0-180 90-270
196Degrees 196
195
196
193
195
189
195
183
193
175
191
166
187
155
182
143
174
129
162
114
147
98
131
79
109
60
85
40
62
45°
Candela Distribution
90°
75°
60°
45°
30°
0°
15°
0
5
10
15
20
25
30
35
40
45
50
55
60
65
70
0-180 90-270
194
Degrees 194
193
194
191
195
186
195
181
193
173
192
164
190
153
185
141
179
128
171
113
160
96
146
78
127
60
106
40
82
90°
75°
60°
45°
30°
0°
15°
4 x 36 W
Efficiency 61.5%
NF C 71-121: 0.61 E
Candela Distribution
0
5
10
15
20
25
30
35
40
45
50
55
60
65
70
1124
0-180 90-270
190
190
Degrees
289
190
287
190
183
189
177
188
170
186
162
182
151
178
139
172
126
163
111
152
96
138
78
121
60
102
42
80
90°
75°
60°
45°
30°
0°
15°
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
RE Series Recessed Fluorescent Luminaire Photometric Data
Standard and Emergency Back-Up. Increased Safety
Zone 1 & 2 – 21 & 22
II 2 GD
ATEX / IECEx
IP66 - IK09/10
Longitudinal
Transverse
Polar curves for a 1000 lm flux, according to NF C 71-120
Luminaire symbol according to NF C 71-121
1 x 36 W
Efficiency 64.4%
NF C 71-121: 0.64 E
2 x 36 W
Efficiency 64.8%
NF C 71-121: 0.64 E
3 x 36 W
Efficiency 63.7%
NF C 71-121: 0.63 F
Candela Distribution
0-180 90-270
0-180 90-270
Candela Distribution
0-180 90-270
0
196
196
0
198
198
0
207
5
195Degrees 196
5
197Degrees 198
5
207Degrees 208
207
10
192
196
90°
10
194
198
90°
10
204
208
90°
15
188
194
15
190
197
75°
15
199
206
75°
20
182
192
75°
20
184
196
20
193
204
25
174
189
25
176
195
25
185
202
30
165
188
30
167
195
30
175
200
35
154
185
35
156
194
35
164
196
40
152
181
40
144
191
40
151
189
45
129
176
45
130
184
45
136
178
50
114
170
50
115
172
50
120
162
55
97
159
55
98
154
55
103
139
60
80
143
60
80
129
60
84
112
65
61
116
65
62
101
65
65
83
70
43
76
70
43
72
70
45
55
60°
45°
30°
0°
15°
1 x 58 W
Efficiency 64.9%
NF C 71-121: 0.65 E
45°
30°
0°
15°
2 x 58 W
Efficiency 61.8%
NF C 71-121: 0.62 E
Candela Distribution
0-180 90-270
189 Degrees189
188
189
187
188
184
187
181
186
176
185
170
185
162
184
150
180
136
175
119
169
102
162
83
146
63
122
43
85
0-180 90-270
182 Degrees182
182
183
181
183
178
182
174
182
170
182
164
181
156
181
145
178
131
172
116
162
99
148
81
126
52
99
43
70
90°
75°
60°
45°
30°
0°
15°
0
5
10
15
20
25
30
35
40
45
50
55
60
65
70
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
60°
45°
30°
0°
15°
3 x 58 W
Efficiency 57.8%
NF C 71-121: 0.58 E
Candela Distribution
90°
75°
60°
45°
30°
0°
15°
0
5
10
15
20
25
30
35
40
45
50
55
60
65
70
0-180 90-270
185 Degrees185
185
185
183
185
181
184
177
182
172
180
166
178
159
174
147
168
133
158
118
144
100
125
82
101
63
75
43
49
90°
75°
60°
45°
30°
0°
15°
1125
Lighting
Candela Distribution
0
5
10
15
20
25
30
35
40
45
50
55
60
65
70
60°
Lighting: Enclosed and Gasketed — Area — Recessed Fluorescent
Candela Distribution
Stylmaster™ Incandescent Luminaires
Enclosed and Gasketed
Attractively styled fixture with prismatic globe. UNILETS® for use with threaded metal conduit.
NEC:
Class I, Division 2, Groups A, B, C, D
CSA: V
Class I, Division 2, Groups A, B, C, D
Class II, Division 1 and 2, Groups E, F, G
Class III
Enclosure 4X
Applications
• Enclosed and gasketed lighting fixtures for use in storage
areas, tunnels, subways, chemical plants and other areas where
moisture, dirt or corrosive atmospheres are a problem.
• Suitable for use in wet locations.
• Standard fixtures designed for 60 to 300 Watt medium base
incandescent lamps.
• Pendant, feed-thru, ceiling, stanchion and wall mounts available.
• Ventilated steel reflectors with white porcelain finish are
available for standard applications. Fiberglass reinforced
polyester reflectors are designed for installations where fixture
is subject to severe corrosive conditions or vandalism.
Lighting: Enclosed and Gasketed — Area — Incandescent
Features
• Modern styling, with clean-line mounting hood and prismatic
glass globe, plus optional guard.
• Prismatic globe, furnished as standard, eliminates glare
and distributes light evenly.
• Globe seats firmly against composition gasket in mounting
hood to keep out dirt and moisture. Full threads eliminate
“cross threading.”
• Fixture is complete with gaskets and socket. Socket is shockabsorbing to prolong lamp life and can be easily removed for
wiring without tools.
• Porcelain socket construction assures long trouble-free
operation in high ambient installations.
• Both porcelain steel and polyester reflectors are secured to
mounting hoods with screws (furnished).
• Guards have exclusive snap-on attachment feature for quick
installation and fast servicing.
• Choice of reflector styles:
(1) steel reflector with white porcelain enamel in standard dome
and 30º angle
(2) fiberglass reinforced polyester reflector in standard dome
and 30º angle.
• Maximum input voltage 277 V (suitable for DC applications).
Illustrated Features
Mounting Hood
Pendant style shown has setscrew to prevent
fixture stem from turning. Other styles include
stanchion, ceiling and wall mounting.
Shock-Absorbing Medium Base Socket
Spring absorbs vibration to prolong lamp
life. Porcelain construction for trouble-free
operation in high ambient installations.
Globe
Attractive, tapered prismatic glass globes
for glare elimination and uniform light
distribution. Colors available – also
vandal-resistant plastic globes. Globe seats
firmly against gasket to exclude moisture, dirt
and vapors.
Guard
Snap-on guards (and reflectors) – simply
snap-in and twist. Spring action balls snap
into detents of fixture body.
Standard Materials
•
•
•
•
•
Mounting hoods: copperfree (4/10 of 1% max.) aluminum
Guards: pressure cast copperfree (4/10 of 1% max.) aluminum
Reflectors: porcelain steel or fiberglass reinforced polyester
Socket: porcelain with brass screw shell
Globes: prismatic glass
Guard and Reflectors
Standard Finishes
•
•
•
•
Mounting hoods and guards: epoxy powder coat
Steel reflectors: baked white porcelain enamel
Fiberglass reinforced polyester reflectors: natural finish
Socket and globes: natural finish
Lighting
Options
• To order fixture with other than standard clear glass globe, add
suffix letters to catalog number as indicated in table, and adjust
difference in price.
Color
Amber
Blue
Green
Red
Clear Heat-Resistant
Glass Globe
-AM
-BL
-GR
-RE
-HR
Plastic Globe
-PAM
-PBL
-PGR
-PRE
—
Certifications and Compliances
•
•
•
•
UL Standard: UL 1598, UL 844
UL Listed: E10444
CSA Standard: C22.2 No. 250, C22.2 No. 137
CSA Certified: 025428
V CSA Certification only.
1126
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
Stylmaster™ Incandescent Luminaire Thermal Suitability
Enclosed and Gasketed
Attractively styled fixture with prismatic globe. UNILETS® for use with threaded metal conduit.
NEC:
Class I, Division 2, Groups A, B, C, D
CSA: V
Class I, Division 2, Groups A, B, C, D
Class II, Division 1 and 2, Groups E, F, G
Class III
Enclosure 4X
Class I, Division 2, Groups A, B, C, D
Fixture is suitable for Class I, Division 2 where the fixture operating temperature does not exceed the ignition
temperature of the atmosphere in which fixture is installed.
“T” Numbers Represent the Maximum Lamp Temperature for Class I, Division 2 Locations
Supply Wire: 392 ºF/200 ºC
“T”
Number
T1
350
325
T2
T2A
T2B
T2C
T2D
T3
T3A
T3B
T3C
T4
T4A
T5
T6
Temp.
Range
(˚ºF)
664842
619662
574617
538572
502536
448500
421446
394419
358392
331356
322329
277320
250275
214248
187212
185
Temp.
Range
(˚ºC)
351450
326350
301325
281300
261280
231260
216230
201215
181200
166180
161165
136160
121135
101120
86-100
85
Class I, Division 2, Groups A, B, C, D
VPGL-1HR (60-200 W)
A-21
A-23
150 W
200 W
A-23
200 W
PS-25
200 W
VPGL-2HR (200-300 W)
PS-30
PS-25
200 W
300 W
PS-30
300 W
T3
T2D
T2C
T2C
T2C
T2C
325
325
Standard Dome
T2D
T2D
T2B
T2B
T2B
T2C
325
325
30º Angle
T2D
T2C
T2B
T2B
T2B
T2B
325
325
None
Fixture Ambient Suitability:
Class II, Groups E, F, G; Class III; Enclosure 4X
Fixture Ambient Suitability:
Areas
ºF
ºC
Fixture
Watts
Non-Classified
392
200
A-23
60 to 300
Classified
104
40
PS-30
60 to 300
Lighting: Enclosed and Gasketed — Area — Incandescent
Reflector
A-21
100 W
Lighting
V CSA Certification only.
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
1127
Stylmaster™ Incandescent Luminaires
Enclosed and Gasketed
Attractively styled fixture with prismatic globe. UNILETS® for use with threaded metal conduit.
NEC:
Class I, Division 2, Groups A, B, C, D
Without Guard
With Guard
CSA: V
Class I, Division 2, Groups A, B, C, D
Class II, Division 1 and 2, Groups E, F, G
Class III
Enclosure 4X
Type
Lamp
Watts
NEC Catalog Numbers
With Globe
With
and Guard
Globe Only
Hub Size
(Inches)
CSA Catalog Numbers V
With Globe
With
and Guard
Globe Only
Pendant — 3/4” tapped opening — Furnished with 3/4” to 1/2” reducer
A-23
60-200
1/2 or 3/4
VPA1075G
VPA1075
VCA1075G
VCA1075
PS-30
200-300
1/2 or 3/4
VPA2075G
VPA2075
VCA2075G
VCA2075
A-23
60-200
PS-30
200-300
1/2
VPX1050G
VPX1050
3/4
VPX1075G
VPX1075
1/2
VPX2050G
VPX2050
3/4
VPX2075G
VPX2075
—
VCX1075G
—
VCX2075G
—
VCX1075
—
VCX2075
Ceiling – Outlet Box Mounting — Fits SEH ➊ or VPJB cast outlet box, or 4” octagonal outlet box — Furnished with screws and
gasket — Octagonal outlet boxes for non-classified areas only
A-23
60-200
3/4
VPOB10G
VPOB10
VCOB10G
VCOB10
PS-30
200-300
3/4
VPOB20G
VPOB20
VCOB20G
VCOB20
A-23
60-200
1-1/4
VPAN10125G
VPAN10125
VCAN10125G
VCAN10125
PS-30
200-300
1-1/4
VPAN20125G
VPAN20125
VCAN20125G
VCAN20125
45˚ Stanchion – 1-1/4” Conduit
Lighting
Lighting: Enclosed and Gasketed — Area — Incandescent
Ceiling – Five Tapped Openings — With mounting lugs and four close-up plugs
➊ Order SEH box from catalog Fittings Section, 4” octagonal steel boxes from the Commercial Products Section and VPJB cast box from this Section.
V CSA Certification only.
1128
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
Stylmaster™ Incandescent Luminaires
Enclosed and Gasketed
Attractively styled fixture with prismatic globe. UNILETS® for use with threaded metal conduit.
NEC:
Class I, Division 2, Groups A, B, C, D
CSA: V
Class I, Division 2, Groups A, B, C, D
Class II, Division 1 and 2, Groups E, F, G
Class III
Enclosure 4X
NEC Catalog Numbers
CSA Catalog Numbers V
With Globe
With
With Globe
With
Lamp
Hub Size
and Guard
Globe Only
and Guard
Globe Only
Without Guard
With Guard
Type
Watts
(Inches)
Wall – Body includes outlet box with five tapped openings — With mounting lugs and four close-up plugs
A-23
60-200
PS-30
200-300
1/2
VPWB1050G
VPWB1050
3/4
VPWB1075G
VPWB1075
1/2
VPWB2050G
VPWB2050
3/4
VPWB2075G
VPWB2075
VCWB1075G
VCWB1075
VCWB2075G
VCWB2075
Wall – Outlet Box Mounting — Fits SEH ➊ or VPJB cast outlet box, or 4” octagonal outlet box — Furnished with screws and gasket
— Octagonal outlet boxes for non-classified areas only
60-200
VPOBW10G
VPOBW10
VCOBW10G
VCOBW10
PS-30
200-300
VPOBW20G
VPOBW20
VCOBW20G
VCOBW20
Wall – Outlet Box Mounting with Side Hubs — With two side hubs and one close-up plug
A-23
60-200
3/4
—
—
VCW1075G
VCW1075
PS-30
200-300
3/4
—
—
VCW2075G
VCW2075
Lighting: Enclosed and Gasketed — Area — Incandescent
A-23
Lighting
➊ Order SEH box from catalog Fittings Section, 4” octagonal steel boxes from the Commercial Products Section and VPJB cast box from this Section.
V CSA Certification only.
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
1129
Stylmaster™ Incandescent Luminaire Accessories
Enclosed and Gasketed
Attractively styled fixture with prismatic globe. UNILETS® for use with threaded metal conduit.
Hub Size
(Inches)
Description
Catalog Numbers
NEC
CSA V
Pendant
Furnished with setscrew, 3/4” to 1/2” reducer for 1/2”
stem, medium base socket.
VPA75
VCA75
VPX50
VCX50
Ceiling – Five Tapped Openings
1/2
Four close-up plugs
VCX75
3/4
Lighting: Enclosed and Gasketed — Area — Incandescent
45º Stanchion
1-1/4
VPAN125
VCAN125
1/2
VPWB50
—
3/4
VPWB75
—
1/2
VPJB50
VCJB50
3/4
VPJB75
VCJB75
VPOB1
VCOB1
VPOBW1
VCOBW1
Wall – Five Tapped Openings in Outlet Box ➊
Four close-up plugs
Cast Outlet Box Only – Five Tapped Openings
Four close-up plugs. No socket. Fits VPOB, VPOBW
and VPWB.
Ceiling – For Outlet Box
(Octagonal outlet boxes for non-classified areas only)
Fits SEH or VPJB cast outlet box, or 4” octagonal outlet
box. With screws and gasket.
Wall – For Outlet Box ➊
(Octagonal outlet boxes for non-classified areas only)
Lighting
Fits SEH or VPJB cast outlet box, or 4” octagonal outlet
box. With screws and gasket.
Wall – Outlet Box Mounting with Side Hubs — With two side hubs and one close-up plug
(Octagonal outlet boxes for non-classified areas only)
3/4
—
VCB75
➊ Use 30º angle reflectors for wall installations – center line of fixture must be located at least 5-3/4” away from wall. Has four 3/16” dia. mounting holes located
90º apart on a 3-1/2” dia. center.
V CSA Certification only.
1130
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
Stylmaster™ Incandescent Luminaire Accessories
Enclosed and Gasketed
Attractively styled fixture with prismatic globe. UNILETS® for use with threaded metal conduit.
Catalog Numbers
Type
Lamp Watts
Color
Glass
Polycarbonate
VPGL-2PL
Glass and Polycarbonate Globes ➊
A-23
Glass Globe
(VPGL-1HR)
Clear
—
Clear Heat-Resistant
VPGL-1HR
—
Amber
VPGL-1AM
VPGL-2AMPL
Blue
VPGL-1BL
VPGL-2BLPL
Green
VPGL-1GR
VPGL-2GRPL
Red
VPGL-1RE
VPGL-2REPL
60-200
Polycarbonate Globe
(VPGL-2PL)
Glass Globes
—
—
VPGL-2HR
—
PS-30
Amber
VPGL-2AM
—
Blue
VPGL-2BL
—
Green
VPGL-2GR
—
VPGL-2RE
—
VPGL-2HRT
—
Red
Glass Globe (VPGL-2HR)
Coated Tuff-Skin ® † Glass Globes Contains globe safely even if glass is broken
Heat-Resistant
VPGL-2HRT
Type
Lamp Watts
A-23
PS-30
60-200
200-300
Catalog Numbers
NEC
CSA V
VPGU-1
VPGU-2
VCFGU-1
VCFGU-2
VPLR-123
VCLR-1
VPGL-GK
VCGL-GK
Guards
VPGU-1
VPGU-2
Lighting: Enclosed and Gasketed — Area — Incandescent
Clear
Clear Heat-Resistant
200-300
Replacement Porcelain Shock-Absorbing Sockets
A-23
60-200
PS-30
200-300
Lighting
Medium Base
Replacement Gasket for Globes
Neoprene – for all Stylmaster globes
Globe Gasket
† Registered trademark of Thomas Manufacturing Corporation, Parkton, Md.
➊ Shatter-resistant for use in food processing plants, canneries, dairies, breweries, bakeries or anywhere broken glass would prove a hazard. Ideally suited for
areas where vandalism, high replacement and high maintenance costs are a problem. CAUTION: Use maximum 200 W lamp less reflector, 100 W max. with
reflector or colored globe. Do not use in ambients exceeding 25 ºC/77 ºF. For burning in vertical base-up position only.
V CSA Certification only.
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
1131
Stylmaster™ Incandescent Luminaire Reflectors and Accessory Weights
Enclosed and Gasketed
Attractively styled fixture with prismatic globe. UNILETS® for use with threaded metal conduit.
Catalog Number
Description
Porcelain Steel
Polyester
Standard Dome Reflector
LPR-25ST
LPRP-25ST
30º Angle Reflector
LPR-25AN
LPRP-25AN
Typical Mounting Hoods
Pendant
VPA75
VCA75
lbs/kg
2/0.9
Ceiling
VPX75
VCX75
lbs/kg
2/0.9
Wall
VPOBW10
VCOBW10
lbs/kg
3/1.4
Stanchion
lbs/kg
VPAN-125
3/1.4
VCAN-125
Globes and Guards
Reflectors
Type
Globe
lbs/kg
Guard
lbs/kg
Standard
Dome
lbs/kg
30˚º Angle
lbs/kg
60-200 W
VPGL-1
2/0.9
VPGU-1
1/0.5
LPR-25ST
3/1.4
LPR-25AN
2/0.9
200-300 W
VPGL-2
3/1.4
VPGU-2
1/0.5
LPRP-25ST
2/0.9
LPRP-25AN
2/0.9
Lighting
Lighting: Enclosed and Gasketed — Area — Incandescent
Weights
1132
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
Stylmaster™ Incandescent Luminaire Dimensions
Enclosed and Gasketed
Attractively styled fixture with prismatic globe. UNILETS® for use with threaded metal conduit.
Pendant Mount ➊
45° Stanchion Mount ➊➋
7.00"/
177.8 mm
10.55"/268.0 mm
9.23"/
234.4 mm
3.00"/
76.2 mm
Ceiling Outlet Box Mount
Ceiling Mount for Junction Box
4.06"/
103.1 mm
1.68"/
42.7 mm †
Wall Outlet Box Mount
5.25"/
133.4 mm
3.50"/
88.9 mm
4.00"/
101.6 mm
3.31"/
84.1 mm †
3.56"/
90.4 mm †
10.63"/
270.0 mm
0.19”/4.8 mm
Dia. Mtg. Hole
3.31"/
84.1 mm
8.75"/
222.3 mm
Junction Box Mounting Body
0.33"/8.4 mm R
(+ DFT) (2 PLACES)
0.13"/3.3 mm R. Max
(8 Places)
0.22"/5.6 mm R
(+ DFT) (2 PLACES)
40
.1
1.88"/
47.8 mm
6
1.
10
FT
"/ .C
D
50 B
3. m / 2"
FT
m
0" . .9 .6 ia
"D
88 3 m D 0"/ +2
.
m .0 ia /
4
D
m 5" m
m 4.7 7 m
0.
12
4
.4
91
m 1.5
m 8
Di "/
a.
+
4.00"/
101.6 mm
DF
T
Lighting: Enclosed and Gasketed — Area — Incandescent
4.00"/
101.6 mm
Wall Mount with Junction Box
7.13"/
181.1 mm
7.00"/
177.8 mm
7.00"/
177.8 mm
7.52"/
191.0 mm
8.08"/
205.2 mm
8.52"/
216.4 mm
8.40"/
213.4mm
6.08"/
154.4 mm
5.96"/
151.4 mm
3.00"/
76.2 mm
6.88"/
174.8 mm
6.52"/
165.6 mm
12.08"/306.8 mm
11.19"/
284.2 mm
Lighting
➊ Height of hood is measured to bottom of flange. Height of globe and guard is from bottom of flange.
➋ Dimensions of angle are from center of pipe. Height is measured from pipe stop in stanchion hood.
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
1133
Stylmaster™ Incandescent Luminaire Dimensions
Enclosed and Gasketed
Attractively styled fixture with prismatic globe. UNILETS® for use with threaded metal conduit.
Without Reflector
Effective Floor Cavity Reflectance (Rfc) is 20%
% Ceiling Rcc
% Walls
Rw
80
50
30
70
10
50
30
50
10
50
30
30
10
50
30
10
10
50
30
0
10
0
1 .739 .689 .645 .684 .640 .598 .583 .548 .517 .489 .464 .439 .404 .384 .365 .322
ROOM CAVITY RATIOS
2 .618 .548 .489 .572 .509 .456 .484 .435 .391 .403 .365 .331 .329 .299 .273 .234
3 .527 .449 .386 .487 .416 .360 .411 .355 .308 .340 .297 .259 .275 .240 .210 .176
4 .460 .378 .316 .425 .351 .294 .358 .299 .253 .297 .250 .212 .239 .202 .172 .140
5 .398 .319 .258 .370 .296 .240 .313 .252 .206 .258 .209 .172 .208 .169 .138 .110
6 .353 .273 .216 .325 .253 .199 .274 .215 .170 .227 .178 .141 .183 .143 .112 .087
7 .312 .234 .181 .288 .216 .167 .242 .183 .141 .199 .152 .116 .161 .122 .092 .069
8 .279 .204 .152 .257 .189 .142 .217 .161 .120 .180 .133 .099 .144 .106 .077 .056
9 .251 .179 .130 .232 .166 .121 .196 .141 .102 .162 .116 .083 .130 .092 .065 .045
10 .226 .157 .112 .208 .146 .104 .177 .124 .087 .146 .102 .070 .118 .081 .054 .037
Standard Dome
Effective Floor Cavity Reflectance (Rfc) is 20%
% Walls
Rw
80
50
30
70
10
50
30
50
10
50
30
30
10
50
30
10
10
50
30
0
10
0
1 .777 .747 .719 .759 .731 .706 .724 .701 .681 .693 .676 .658 .666 .650 .636 .620
ROOM CAVITY RATIOS
2 .679 .631 .589 .665 .620 .583 .636 .599 .566 .610 .580 .552 .587 .561 .537 .521
3 .593 .534 .486 .581 .525 .481 .557 .510 .471 .535 .495 .461 .514 .480 .451 .435
4 .523 .459 .409 .513 .453 .405 .492 .440 .398 .473 .428 .391 .456 .416 .384 .367
5 .459 .391 .340 .449 .385 .337 .433 .376 .334 .416 .366 .328 .401 .358 .323 .307
6 .406 .337 .289 .397 .333 .285 .382 .325 .282 .368 .317 .278 .356 .310 .274 .259
7 .359 .291 .246 .352 .287 .242 .339 .279 .238 .326 .274 .235 .316 .269 .232 .217
8 .323 .257 .211 .316 .254 .210 .305 .248 .208 .295 .243 .205 .284 .238 .203 .188
9 .291 .227 .182 .286 .223 .182 .275 .219 .180 .266 .214 .178 .257 .210 .175 .161
10 .262 .200 .159 .257 .199 .159 .249 .194 .157 .240 .290 .154 .234 .187 .152 .140
30° Angle
Photometric data shown on this page is based on a 200 Watt A-23 lamp
and is representative of the performance for all Stylmaster incandescent
fixtures. For candlepower values of fixtures with other lamps, multiply the
given candlepower values by the following multipliers: for 75 W A19 – 0.31;
for 100 W A19 – 0.45; for 150 W A21 – 0.75; and for 300 W PS25 – 1.65.
For candlepower values of fixtures with guard, multiply by 0.90.
Lighting
Lighting: Enclosed and Gasketed — Area — Incandescent
% Ceiling Rcc
1134
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
V-51® Incandescent Luminaires
Enclosed and Gasketed
UNILETS® for use with threaded metal conduit. Fixtures suitable for use in wet locations. ‡
NEC:
Class I, Division 2, Groups A, B, C, D
CSA: V
Class I, Division 2, Groups A, B, C, D
Class II, Divisions 1 and 2, Groups E, F, G †
Class III
Enclosure 3R
Applications
• Enclosed and gasketed lighting fixtures for use in storage
areas, tunnels, subways, chemical plants and other areas where
moisture, dirt or corrosive atmospheres are a problem.
• Suitable for use in wet locations.
• Standard fixtures designed for 60 to 300 W medium base
incandescent lamps.
• Available in pendant, 45º stanchion, and a variety of ceiling
and wall mountings.
Features
Illustrated Features
Cut-Away View
Connection block is easily removed (loosen
two screws) to permit quick wiring.
Mounting Hood
Available in pendant (shown), ceiling, wall
and 45º stanchion. Pendant has setscrew to
prevent fixture from turning on stem.
Neoprene Ring
Neoprene attachment ring secures reflector to
mounting hood – no tools needed.
Globe Adapter
When adapter is threaded onto mounting
hood, the socket makes electrical contact with
connection block in mounting hood. Available
in malleable iron (VAD-1M and VAD-2M) or
aluminum (VAD-1 and VAD-2).
Porcelain Enamel Reflectors
Standard and 30° angle.
Standard Materials
• Mounting hoods: malleable iron or copperfree (4/10 of 1%
max.) aluminum
• Globe adapters: malleable iron or pressure cast copperfree
(4/10 of 1% max.) aluminum
• Socket: porcelain with brass screw shell
• Globes: glass. Optional globes in polycarbonate plastic
100 W Max
• Guards: steel or pressure cast copperfree (4/10 of 1% max.)
aluminum
• Reflectors: porcelain enamel steel
Guard
Two sealed ball plunger units snap quickly,
easily and securely into cavities of globe
adapter. Guard can be used with or without a
reflector.
Standard Finishes
• Malleable iron mounting hood and globe adapter: triple coat –
(1) zinc electroplate, (2) chromate, and (3) epoxy powder coat
• Aluminum mounting hood, adapter and guard: epoxy powder
coat
• Steel guard: zinc electroplate
• Steel reflectors: white porcelain enamel
• Socket and globes: natural finish
Guard and Reflectors
Lighting: Enclosed and Gasketed — Area — Incandescent
• Furnished with connection block for easy wiring.
• Unitized construction reduces installation and
maintenance costs.
• Shock-absorbing porcelain socket for longer lamp life.
• Neoprene rubber ring in neck of reflector snaps into groove
of mounting hood – protects against vibration and chipping.
• Guard snaps into two recesses of adapter – no clamps
or setscrews.
• Available in three standard fixtures:
(1) V-51 malleable iron mounting hood with aluminum adapter
and guard
(2) all malleable iron (steel guard)
(3) all aluminum
• Maximum input voltage 150 V.
Options
• To order fixture with other than standard clear glass globe, add
suffix letters to catalog number as indicated in table, and adjust
difference in price.
Glass Globe
-AM
-BL
-GR
-RE
-HR
Plastic Globe
-PAM
-PBL
-PGR
-PRE
—
Lighting
Color
Amber
Blue
Green
Red
Clear Heat-Resistant
Certifications and Compliances
•
•
•
•
UL Standard: UL 1598, UL 844
UL Listed: E10444
CSA Standard: C22.2 No. 250, C22.2 No. 137
CSA Certified: 025428
† 300 W PS-25 NOT approved for Class II, Division 1 and 2, Group G; Class III.
‡ With heat-resistant glass globes or plastic globes.
V CSA Certification only.
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
1135
V-51® Incandescent Luminaires
Enclosed and Gasketed
UNILETS® for use with threaded metal conduit. Fixtures suitable for use in wet locations. ‡
NEC:
Class I, Division 2, Groups A, B, C, D
CSA: V
Class I, Division 2, Groups A, B, C, D
Class II, Divisions 1 and 2, Groups E, F, G †
Class III
Enclosure 3R
Class I, Division 2, Groups A, B, C, D
Fixture is suitable for Class I, Division 2 where the fixture operating temperature does not exceed the ignition
temperature of the atmosphere in which fixture is installed.
“T” Numbers Represent the Maximum Lamp Temperature for Class I, Division 2 Locations
Supply Wire: 257 ºF/125 ºC
“T”
Number
T1
350
325
T2
T2A
T2B
T2C
T2D
T3
T3A
T3B
T3C
T4
T4A
T5
T6
Temp.
Range
(˚ºF)
664842
619662
574617
538572
502536
448500
421446
394419
358392
331356
322329
277320
250275
214248
187212
185
Temp.
Range
(˚ºC)
351450
326350
301325
281300
261280
231260
216230
201215
181200
166180
161165
136160
121135
101120
86-100
85
Class I, Division 2, Groups A, B, C, D
Reflector
200-300 W
PS-25
150 W
PS-30
200 W
PS-30
300 W
None
T3
T2D
T2C
325
Standard Dome
T2D
T2C
T2B
325
30º Angle
T2C
T2C
T2B
325
Fixture Ambient Suitability:
Class I, Division 2, Groups A, B, C, D
Fixture Ambient Suitability:
Class II, Groups E, F, G; Class III; Enclosure 4X
Areas
ºF
ºC
Fixture
Watts
Non-Classified
167
Classified
104
75
A-23
60 to 300
40
PS-30
60 to 300
Lighting
Lighting: Enclosed and Gasketed — Area — Incandescent
60-150 W
A-21
100 W
† 300 W PS-25 not approved for Class II, Division 1 and 2, Group G; Class III.
‡ With heat-resistant glass globes or plastic globes.
V CSA Certification only.
1136
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
V-51® Incandescent Luminaires
Enclosed and Gasketed
UNILETS® for use with threaded metal conduit. Fixtures suitable for use in wet locations. ‡
NEC:
Class I, Division 2, Groups A, B, C, D
Malleable Mounting
Hood, Aluminum
Adapter and Guard
Malleable Mounting
Hood, Adapter
and Guard
CSA: V
Class I, Division 2, Groups A, B, C, D
Class II, Divisions 1 and 2, Groups E, F, G †
Class III
Enclosure 3R
Type
Lamp
Watts
Size
(Inches)
Malleable Mounting Hood
with Aluminum Guard
Catalog Numbers ①
All Malleable
with Guard
All Aluminum
with Guard
Pendant
A-21
PS-30
60-150
150-300
1/2
VA1050G
VA1050G-M
VA1050G-A
3/4
VA1075G
VA1075G-M
VA1075G-A
1
VA1100G
VA1100G-M
—
1-1/4
VA1125G
VA1125G-M
1/2
VA2050G
VA2050G-M
VA2050G-A
3/4
VA2075G
VA2075G-M
VA2075G-A
1
VA2100G
VA2100G-M
—
1-1/4
VA2125G
VA2125G-M
—
1/2
VXHA1050G
VXHA1050G-M
VXHA1050G-A
3/4
VXHA1075G
VXHA1075G-M
VXHA1075G-A
1
VXHA1100G
VXHA1100G-M
VXHA10100G-A
1/2
VXHA2050G
VXHA2050G-M
VXHA2050G-A
3/4
VXHA2075G
VXHA2075G-M
VXHA2075G-A
1
VXHA2100G
VXHA2100G-M
VXHA20100G-A
—
Ceiling — Five Tapped Openings — Four close-up plugs
PS-30
60-150
150-300
Wall — JB Box Mounting ② — Fits JB cast outlet box ③ — Screws and gasket furnished with fixture
A-21
60-150
PS-30
150-300
JBW10G
JBW20G
JBW10G-M
JBW10G-A
JBW20G-M
JBW20G-A
Lighting: Enclosed and Gasketed — Area — Incandescent
A-21
Ceiling – JB Box Mounting ② — Fits JB cast outlet box ③ — Screws and gasket furnished with fixture
60-150
JB10G
JB10G-M
JB10G-A
PS-30
150-300
JB20G
JB20G-M
JB20G-A
Lighting
A-21
† 300 W PS-25 not approved for Class II, Division 1 and 2, Group G; Class III.
‡ With heat-resistant glass globes or plastic globes.
① To order fixtures without guards, omit G suffix from catalog number. Order reflectors and accessories separately.
② 30º angle reflector adaptable for 100 W fixture only, when mounted at least 4.5”/114.3 mm from wall.
③ JB cast outlet box is available in the Fitting Section.
V CSA Certification only.
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
1137
V-51® Incandescent Luminaires
Enclosed and Gasketed
UNILETS® for use with threaded metal conduit. Fixtures suitable for use in wet locations. ‡
NEC:
Class I, Division 2, Groups A, B, C, D
CSA: V
Class I, Division 2, Groups A, B, C, D
Class II, Divisions 1 and 2, Groups E, F, G †
Class III
Enclosure 3R
Type
Lamp Watts
A21
60-150
PS30
150-300
A21
60-150
PS30
150-300
Size
(Inches)
Catalog Numbers ①
Malleable Mounting Hood
Aluminum Mounting Hood
with Aluminum Guard
and Guard
Feed-Thru
1/2
VC1050G
VC1050G-A
3/4
VC1075G
VC1075G-A
1/2
VC2050G
VC2050G-A
3/4
VC2075G
VC2075G-A
1/2
VT1050G
—
3/4
VT1075G
—
1/2
VT2050G
—
3/4
VT2075G
—
Lighting: Enclosed and Gasketed — Area — Incandescent
Ceiling – Three Hubs
Outlet Box Mounting — For SEH cast outlet box ② or 3-1/4” or 4” octagonal outlet box ③ for non-classified areas only — Gasket
and adapter plate furnished with fixture
A21
60-150
OBV10G
OBV10G-A
PS30
150-300
OBV20G
OBV20G-A
A21
60-150
VX1050G
—
Ceiling – Four Hubs
150-300
3/4
VX1075G
—
1/2
VX2050G
—
3/4
VX2075G
—
Lighting
PS30
1/2
† 300 W PS-25 not approved for Class II, Division 1 and 2, Group G; Class III.
‡ With heat-resistant glass globes or plastic globes.
① To order fixtures without guards, omit G suffix from catalog number. Order reflectors and accessories separately.
② SEH cast outlet box is available in the Fitting Section.
③ Octagonal outlet box is available in the Commercial Fitting Section.
V CSA Certification only.
1138
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
V-51® Incandescent Luminaires
Enclosed and Gasketed
UNILETS® for use with threaded metal conduit. Fixtures suitable for use in wet locations. ‡
NEC:
Class I, Division 2, Groups A, B, C, D
CSA: V
Class I, Division 2, Groups A, B, C, D
Class II, Divisions 1 and 2, Groups E, F, G †
Class III
Enclosure 3R
Type
Lamp Watts
A21
60-150
PS30
150-300
A21
60-150
PS30
150-300
A21
60-150
Size
(Inches)
Catalog Numbers ①
Malleable Mounting Hood
Aluminum Mounting Hood
with Aluminum Guard
and Guard
Ceiling – Single Hub
1/2
V1050G
V1050G-A
3/4
V1075G
V1075G-A
1/2
V2050G
V2050G-A
3/4
V2075G
V2075G-A
Wall – One Tapped Hub in Flange ②
VGA1050G
—
3/4
VGA1075G
—
1/2
VGA2050G
—
3/4
VGA2075G
—
1/2
VD1050G
—
Lighting: Enclosed and Gasketed — Area — Incandescent
1/2
Wall – Vertical Feed-Thru ②
PS30
150-300
3/4
VD1075G
—
1/2
VD2050G
—
3/4
VD2075G
—
1/2
VGAT1050G
—
3/4
VGAT1075G
VGAT1075G-A
1/2
VGAT2050G
—
3/4
VGAT2075G
VGAT2075G-A
Wall – Three Hubs Plus One Tapped Opening in Center of Flange ②
60-150
PS30
150-300
† 300 W PS-25 not approved for Class II, Division 1 and 2, Group G; Class III.
‡ With heat-resistant glass globes or plastic globes.
① To order fixtures without guards, omit G suffix from catalog number. Order reflectors and accessories separately.
② 30º angle reflector adaptable for 100 W fixture only, when mounted at least 4.5”/114.3 mm from wall.
V CSA Certification only.
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
1139
Lighting
A21
V-51® Incandescent Luminaires
Enclosed and Gasketed
UNILETS® for use with threaded metal conduit. Fixtures suitable for use in wet locations. ‡
NEC:
Class I, Division 2, Groups A, B, C, D
CSA: V
Class I, Division 2, Groups A, B, C, D
Class II, Divisions 1 and 2, Groups E, F, G †
Class III
Enclosure 3R
Type
Catalog Numbers ①
Malleable Mounting Hood
Aluminum Mounting Hood
with Aluminum Guard
and Guard
Lamp Watts
45˚ Stanchion — Reflector not available for this fixture
A21
60-150
1-1/4
—
VMAN10125G-A
PS30
150-300
1-1/4
—
VMAN20125G-A
A21
60-150
OBVW10G
OBVW10G-A
PS30
150-300
OBVW20G
OBVW20G-A
Ceiling – GS Form 20 Box Mounting — Fits GS cast outlet box ③ — Screws and gasket furnished with fixture
A21
60-150
GS102G
—
PS30
150-300
GS202G
—
Wall – GS Box Mounting ② — Fits GSU cast outlet box ③ — Screws and gasket furnished with fixture
A21
60-150
GSW102G
—
PS30
150-300
GSW202G
—
Lighting
Lighting: Enclosed and Gasketed — Area — Incandescent
Wall – Outlet Box Mounting ② — Fits VPJB outlet box, SEH cast outlet box ③ or 3-1/4” or 4” octagonal outlet box ④ for nonclassified areas only — Gasket and adapter plate furnished with fixture
† 300 W PS-25 not approved for Class II, Division 1 and 2, Group G; Class III.
‡ With heat-resistant glass globes or plastic globes.
① To order fixtures without guards, omit G suffix from catalog number. Order reflectors and accessories separately.
② 30º angle reflector adaptable for 100 W fixture only, when mounted at least 4.5”/114.3 mm from wall.
③ Cast outlet boxes are available in the Fitting Section.
④ Octagonal outlet boxes are available in the Commercial Fitting Section.
V CSA Certification only.
1140
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
V-51® Incandescent Luminaire Accessories
Enclosed and Gasketed
UNILETS® for use with threaded metal conduit.
Catalog Numbers
Description
Hub Size (Inches)
Malleable Iron
Aluminum
Pendant and Ceiling Mounting Hoods — Furnished with connection block, gasket and screws
Pendant Mounting
1/2
VA50
VA50-A
3/4
VA75
VA75-A
1
VA100
—
1-1/4
VA125
—
Dead-End — Ceiling Mounting
1/2
V50
V50-A
3/4
V75
V75-A
Feed-Thru — Ceiling Mounting
1/2
VC50
VC50-A
3/4
VC75
VC75-A
Three Hubs — Ceiling Mounting
VT50
—
VT75
—
Lighting: Enclosed and Gasketed — Area — Incandescent
1/2
3/4
Four Hubs — Ceiling Mounting
1/2
VX50
—
3/4
VX75
—
Five Hubs — Ceiling Mounting ①
1/2
VXHA50
VXHA50-A
3/4
VXHA75
VXHA75-A
1
VXHA100
VXHA100-A
Wall and Stanchion Mounting Hoods — Furnished with connection block, gasket and screws
One Opening — Wall Mounting ② — 1 tapped hole in center of flange
1/2
VGA50
—
3/4
VGA75
—
Feed-Thru — Wall Mounting ② — 2 tapped vertical feed-thru hubs
1/2
VD50
—
3/4
VD75
—
Three Hubs and One Opening – Wall Mounting ② — 3 hubs plus 1 tapped opening in
center of flange
VGAT50
VGAT75
—
Lighting
1/2
3/4
VGAT75-A
45° Stanchion Mounting
1-1/4
—
VMAN-125
① Four close-up plugs furnished.
② Mounting hoods for wall installations can only be used with 30º angle reflectors.
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
1141
V-51® Incandescent Luminaire Accessories
Enclosed and Gasketed
UNILETS® for use with threaded metal conduit.
Wall
Ceiling
Catalog Numbers
Malleable Iron
Aluminum
Type
Wall and Ceiling Outlet Box Mounting Hoods
SEH ① and 3-1/4” or 4” Octagonal Outlet Box Mounting ② for Non-Classified Areas Only
Wall ③
OBVW1
OBVW1-A
Ceiling
OBV1
OBV1-A
GS Round Base Outlet Box Mounting – Form 20 ①
Wall ③
GSW2
—
Ceiling
GS2
—
Lighting: Enclosed and Gasketed — Area — Incandescent
JB Round Base Outlet Box Mounting ①
A21
PS30
Type
Wall ③
JBW1
JBW1-A
Ceiling
JB1
JB1-A
Catalog Numbers
Malleable Iron
Aluminum
Lamp Watts
Fixture Units
Adapter/Socket, Globe and Guard
A21
60-150
VU100M
VU-100
PS30
150-300
VU200M
VU-200
Adapter/Socket and Globe
A21
60-150
VU100MLG
VU-100LG
PS30
150-300
VU200MLG
VU-200LG
Lighting
Adapter/Socket
A21
60-150
VAD-1M ④
VAD-1
PS30
150-300
VAD-2M ④
VAD-2
① Cast outlet boxes and gaskets are available in the Fitting Section. Screws, gasket and adapter plate furnished with fixture mounting hood.
② Octagonal outlet boxes are available in the Commercial Fitting Section. Screws, gasket and adapter plate furnished with fixture mounting hood.
③ Mounting hoods for wall installations can only be used with 30º angle reflectors.
④ Accepts steel wire guard only
1142
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
V-51® Incandescent Luminaire Accessories
Enclosed and Gasketed
UNILETS® for use with threaded metal conduit.
Type
Lamp Watts
Catalog Numbers
Glass — 60-150 W
Polycarbonate ‑ 100 W Max. ①
Glass and Polycarbonate Globes — 60-150 W
60 W-150 W Glass
100 W Polycarbonate
Clear
VGL-1CL
VPG-1CL
Amber
VGL-1AM
VPG-1AM
Blue
VGL-1BL
VPG-1BL
Green
VGL-1GR
VPG-1GR
Opal
VGL-1OP
Red
VGL-1RE
Clear Heat-Resistant
VGL-1HR
—
—
VPG-1RE
Glass Globes — 150-300W
VGL-2CL
—
VGL-2AM
—
—
Blue
VGL-2BL
Green
VGL-2GR
—
Opal
VGL-2OP
—
Red
VGL-2RE
—
Clear Heat-Resistant
VGL-2HR
—
Lighting: Enclosed and Gasketed — Area — Incandescent
Clear
Amber
Aluminum Guards ②
A21
③
60-150
VGU-1
PS30
④
150-300
VGU-2
A21
⑤
60-150
VWG-1
PS30
⑥
150-300
VWG-2
VGU-2
Steel Wire Guards ②
Lighting
VWG-1
① Do not use in ambients exceeding 77 ºF/25º C. For burning in base-up position only.
② Cannot be used with polycarbonate globes.
③ Fits VAD-1 Adapter)
④ Fits VAD-2 Adapter)
⑤ Fits VAD-1M Adapter)
⑥ Fits VAD-2M Adapter)
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
1143
V-51® Incandescent Luminaire Accessories
Enclosed and Gasketed
UNILETS® for use with threaded metal conduit.
Description
Type
Lamp Watts
Catalog Number
Porcelain Reflectors — Furnished with neoprene attaching ring
Standard Dome
A21
60-150
VRW-1ST
PS30
150-300
VRW-2ST
A21
60-150
VRW-1AN
PS30
150-300
VRW-2AN
30˚ Angle
Lighting: Enclosed and Gasketed — Area — Incandescent
Replacement Reflector Attaching Ring — Neoprene
VPT-8
Connection Block
VPT-7
Lamp Socket — Medium Base
VPT-1AV
Gasket for Lamp Socket and 60-150 W Globe
VPT-2
Gasket for 150-300 W Globe
Lighting
VPT-3
Gasket for Mounting Hood
VPT-4
1144
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
V-51® Incandescent Luminaire Dimensions
Enclosed and Gasketed
UNILETS® for use with threaded metal conduit.
Dimensions in Inches/Millimeters
5.19"/
131.8 mm
3.81"/
96.8mm
3.81"/
96.8 mm
4.44"/
112.8 mm
Types V, VC, VT and VX
Type VXHA
3.50"/
88.9 mm
2.38"/
60.5 mm
2.63"/
66.8 mm
2.63"/
66.8 mm
3.00"/
76.2 mm
0.94"/
23.9 mm
Types OBV and OBVW
3.50"/
12.7mm
4.50"/
114.3 mm
4.00"/
101.6 mm
4.00"/
101.6 mm
3.06"/
77.7 mm
3.50"/
12.7mm
4.63"/
117.6 mm
4.00"/
101.6 mm
2.19"/
55.6 mm
4.63"/
117.6 mm
0.75"/
19.1 mm
Types VGA and VGAT
Type VD
Types JB and JBW
Types GS and GSW
Size
A
B
C
1/2 & 3/4
D
1 & 1-1/4
D
60-150 W
6.38/162.1
5.75/146.1
4.19/106.4
2.63/66.8
2.89/73.4
150-300 W
9.50/241.3
8.63/219.2
5.69/144.5
2.63/66.8
2.89/73.4
Reflectors
Lighting: Enclosed and Gasketed — Area — Incandescent
4.50"/
114.3 mm
5.00"/
127 mm
2.75"/
69.9 mm
2.19"/
55.6 mm
Type VA
3.50"/
12.7mm
5.00"/
127 mm
Lighting
Standard Dome
30˚ Angle
Standard Dome
30˚ Angle
Size
A
B
A
B
60-150 W
6.19/157.2
12.00/304.8
8.09/205.5
10.00/254.0
150-300 W
8.88/225.6
16.00/406.4
11.59/294.4
12.00/304.8
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
1145
V-51® Incandescent Luminaire Photometric Data
Enclosed and Gasketed
UNILETS® for use with threaded metal conduit. Full-size photometric data available for all V-51® fixtures on request.
Without Reflector
Effective Floor Cavity Reflectance (Rfc) is 20%
% Ceiling Rcc
% Walls
Rw
80
50
30
70
10
50
30
50
10
50
30
30
10
50
30
10
10
50
30
0
10
0
1 .815 .765 .721 .755 .711 .668 .642 .608 .577 .539 .513 .489 .444 .424 .406 .360
ROOM CAVITY RATIOS
2 .690 .619 .558 .639 .575 .521 .542 .492 .449 .452 .414 .380 .370 .341 .315 .273
3 .595 .515 .450 .551 .478 .421 .467 .410 .362 .388 .344 .307 .316 .282 .252 .215
4 .523 .439 .374 .485 .409 .350 .411 .351 .303 .343 .296 .257 .279 .242 .212 .178
5 .457 .376 .313 .426 .350 .292 .362 .300 .254 .302 .253 .215 .246 .208 .177 .147
6 .409 .326 .266 .378 .303 .248 .322 .261 .215 .269 .220 .183 .220 .180 .150 .123
7 .364 .283 .229 .338 .264 .213 .288 .226 .184 .240 .192 .155 .198 .158 .128 .104
8 .329 .251 .197 .305 .234 .185 .260 .202 .160 .220 .171 .136 .179 .141 .112 .090
9 .298 .223 .171 .277 .208 .161 .237 .180 .140 .199 .152 .119 .164 .126 .098 .078
10 .271 .198 .152 .251 .187 .142 .216 .161 .123 .182 .137 .104 .151 .113 .086 .068
Effective Floor Cavity Reflectance (Rfc) is 20%
% Ceiling Rcc
% Walls
Rw
80
50
30
70
10
50
30
50
10
50
30
30
10
50
30
10
10
50
30
0
10
0
1 .803 .772 .744 .784 .756 .731 .750 .726 .706 .718 .701 .683 .691 .675 .661 .645
ROOM CAVITY RATIOS
2 .705 .656 .614 .690 .645 .608 .661 .624 .591 .636 .605 .576 .612 .586 .562 .546
3 .618 .558 .511 .606 .550 .506 .583 .535 .495 .560 .520 .486 .540 .506 .476 .460
4 .549 .484 .434 .538 .478 .430 .518 .465 .423 .499 .454 .417 .482 .442 .410 .393
5 .485 .416 .366 .475 .411 .363 .459 .401 .359 .442 .392 .354 .427 .384 .349 .333
6 .431 .362 .314 .423 .358 .310 .408 .350 .307 .394 .343 .304 .382 .335 .299 .284
7 .384 .316 .270 .377 .311 .267 .364 .304 .263 .351 .299 .260 .341 .294 .257 .242
8 .347 .281 .234 .340 .278 .233 .329 .272 .231 .319 .267 .229 .309 .262 .226 .212
9 .314 .249 .204 .309 .246 .204 .299 .242 .202 .289 .237 .200 .281 .233 .198 .184
10 .284 .221 .181 .279 .221 .181 .271 .216 .179 .263 .212 .176 .257 .209 .174 .161
30° Angle
Photometric data shown on this page is based on a 150 Watt PS-25 lamp
and is representative of the performance for all V-51 incandescent fixtures.
For candlepower values of fixtures with other lamps, multiply the given
candlepower values by the following multipliers: for 60 W – A19 X 0.33; for
75 W – A19 X 0.45; for 100 W – A19 X 0.66; for 200 W – PS25 X 1.44; and
for 300 W – PS30 X 2.32. For candlepower values of fixture with guard,
multiply by 0.90.
Lighting
Lighting: Enclosed and Gasketed — Area — Incandescent
Standard Dome
1146
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
REA™ 150 W Incandescent Luminaires ①
Enclosed and Gasketed
UNILETS® for use with Threaded Metal Conduit. Medium Base. Inexpensive, Low Wattage Fixture for use in Wet Locations.
Applications
• Vaportight enclosed and gasketed lighting fixtures, suitable for
use in wet locations.
• Standard glass globes take up to 150 W A-21 lamps. Optional
polycarbonate plastic globes take up to 100 W A-21 lamps.
Features
• Inexpensive fixture designed for use without reflector.
• Spring-mounted shock-absorbing socket prolongs lamp life.
• Guards snap on easily and securely. Spring-action balls snap
into detents in fixture body.
Standard Materials
• Mounting bodies: pressure cast copperfree (4/10 of 1% max.)
aluminum
• Socket: porcelain with brass screw shell
• Guards: steel or aluminum guards
Standard Finishes
Pendant
Mounting bodies: burnished
Steel wire guard: zinc electroplate
Aluminum guard: aluminum polymer enamel
Socket and globes: natural finish
Outlet Box
Wall
Lighting: Enclosed and Gasketed — Area — Incandescent
•
•
•
•
Certifications and Compliances
• UL Standard: UL 1598
Dimensions in Inches/Millimeters
3.19"/
81.0 mm
3.50"/
12.7 mm
4.19"/
106.4 mm
8.25"/
209.6 mm
11.81"/
300.0 mm
6.38"/
162.1 mm
Lighting
3.94"/
100.1 mm
Pendant
3.75"/
96.3 mm
3.94"/
100.0 mm
Outlet Box
Wall
① Maximum size A-21 lamp: glass globe – 150 Watts; plastic globe – 100 Watts. No reflectors are available for REA fixtures.
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
1147
REA™ 150 W Incandescent Luminaires ①
Enclosed and Gasketed
UNILETS® for use with Threaded Metal Conduit. Medium Base. Inexpensive, Low Wattage Fixture for use in Wet Locations.
Description
Hub Size
(Inches)
Catalog Number
1/2
3/4
REA-1050
REA-1075
Pendant Fixture
Pendant
Outlet Box
Outlet Box Fixture
For 3-1/4” or 4” octagonal, or 4” square mounting.
REA-10B
Wall Fixture
REA-10LB
Wall
Pendant Hood
Lighting: Enclosed and Gasketed — Area — Incandescent
1/2
3/4
REA-50
REA-75
Wall Bracket
1/2 male stem
REA-1BR
Lamp Socket
VPLR-123
Steel Guard
VWG-1
For Outlet Box fixture only.
Aluminum Guard
For Pendant and Wall Mount fixtures only.
VWG-1
VGU-1
VGU-1
Catalog Number ①
Glass
Plastic
Description
Lighting
Colored Glass and Polycarbonate Globes
Glass
Plastic
Clear
VGL-1CL
VPG-1CL
Amber
VGL-1AM
VPG-1AM
Blue
VGL-1BL
VPG-1BL
Green
VGL-1GR
VPG-1GR
Opal
VGL-1OP
—
Red
VGL-1RE
VPG-1RE
Clear Heat-Resistant
VGL-1HR
—
① Maximum size A-21 lamp: glass globe – 150 Watts; plastic globe – 100 Watts. No reflectors are available for REA fixtures.
1148
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
Areamaster™ 100 Wide-Beam Floodlights
70 W, 100 W, 150 W HPS; 70 W, 100 W, 150 PSMH
For general, marine and hazardous locations.
NEC
Class I, Division 2, Groups A, B, C, D
Marine type electric fixtures, outside type
(salt water)
CEC V
Class I, Division 2, Groups A, B, C, D
Class II, Divisions I and 2, Groups E, F, G V
Class III
Marine type electric fixtures, outside type
(salt water)
Applications
• Highly efficient, all-weather flood-lighting for lower wattage
service. Well suited for:
— Facades
— Amusement and recreational areas
— Parking lots
— Industrial and marine use
Features
• Ruggedly built for dependable, vandal resistant service.
Attractively styled. Easy to install, aim, add service, with easy
access to spacious interior.
.• Integral ballast.
• One-piece housing.
• One-piece lens cover. Secured by four 1/4” dia. captive
stainless steel slotted hex-head bolts.
• Thermal shock and impact resistant glass lens.
• Heavy duty, high temperature silicone rubber gasket, firmly
seated.
• Heavy duty mogul-base porcelain socket with heavy gauge
brass, nickel-plated, double lamp-grip screw shell and springloaded center contact.
• Parabolic finished aluminum reflector for optimum efficiency.
• Mounting choice:
(1) Yoke mount, zinc plated steel yoke with architectural bronze
polyester finish
(2) Pole mount, built-in slip-fitter, for internal wiring, adjustable
laterally and vertically, slip fits 2” or 2-1/2” pipe, architectural
bronze polyester finish
Yoke Mount
Standard Materials
• Ballast housing and lens cover: copperfree (4/10 of 1% max.)
aluminum
• Gasket: silicone rubber
• Socket: heavy duty porcelain with heavy gauge brass shell
• Reflector: finished aluminum
• Yoke mount: zinc plated steel
• Bolts: stainless steel
Pole Mount
Lighting: Enclosed and Gasketed — Floodlight
Standard Finishes
• Ballast housing, lens cover, yoke and pole mount: architectural
bronze polyester
• Socket: nickel-plated
Certifications and Compliances
• UL Standard: UL 1598, UL 1598A, UL 844
• UL Listed: E10794
• CSA Certified: LR25428
Lighting
V CSA Certification only.
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
1149
Areamaster™ 100 Wide-Beam Floodlights
70 W, 100 W, 150 W HPS
For general, marine and hazardous locations.
NEC
Class I, Division 2, Groups A, B, C, D
Marine type electric fixtures, outside type
(salt water)
Yoke Mount
Pole Mount
Lamp Watts
Lamp Type
70
HPS
120/208/240/277
G-AM271L-MT-I/2
G-AM271L-MT
G-AM275L-MT
70
HPS
480
G-AM271L-48-I/2
G-AM271L-48
G-AM275L-48
100
HPS
120/208/240/277
G-AM371L-MT-I/2
G-AM371L-MT
G-AM375L-MT
100
HPS
480
G-AM371L-48-I/2
G-AM371L-48
G-AM375L-48
150
HPS
120/208/240/277
G-AM471L-MT-I/2
G-AM471L-MT
G-AM475L-MT
150
HPS
480
G-AM471L-48-I/2
G-AM471L-48
G-AM475L-48
Lighting
Lighting: Enclosed and Gasketed — Floodlight
Electrical Specifications
Line
Type of
Starting
Voltage
Ballast
Amps
70 Watt High Pressure Sodium
120
HX-HPR
0.90
208
HX-HPR
0.50
240
HX-HPR
0.44
277
HX-HPR
0.35
480
HX-HPR
0.21
100 Watt High Pressure Sodium
120
HX-HPR
1.30
208
HX-HPR
0.76
240
HX-HPR
0.66
277
HX-HPR
0.60
480
HX-HPR
0.33
150 Watt High Pressure Sodium
120
HX-HPR
2.00
208
HX-HPR
1.16
240
HX-HPR
1.00
277
HX-HPR
0.85
480
HX-HPR
0.50
Marine Yoke Mount ➊ for
Class I, Division 2 Classified Duty
Catalog Number
Yoke Mount ➊
for General Duty
Line
Voltages
Slip-Fit Mount ➋
T Numbers and Temperature Ratings of “Classified Duty”
Operating
Amps
Total
Watts
0.82
0.48
0.41
0.36
0.21
94
94
94
94
94
1.15
0.67
0.60
0.52
0.31
130
130
130
130
135
1.70
0.95
0.85
0.72
0.47
188
188
188
188
188
Lamp
Watts
70
100
150
T Rating
T3
T2C
T2
Ambient
Temperature (°F/°C)
104/40
104/40
104/40
T Rating Temperature
Range (°F/°C)
358-392/181-200
421-446/216-230
538-572/281-300
➊ Adjustable yoke mounts directly or with adapters.
➋ Internally wired, adjustable slip-fit mount for 2” or 2-1/2” pipe.
1150
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
Areamaster™ 100 Wide-Beam Floodlights V
70 W, 100 W, 150 W HPS; 70 W, 100 W, 150 PSMH
For general, marine and hazardous locations.
CEC V
Class I, Division 2, Groups A, B, C, D
Class II, Divisions I and 2, Groups E, F, G V
Class III
Marine type electric fixtures, outside type
(salt water)
Catalog Number
Lamp
Watts
Yoke Mount
Slip-Fit
Lamp
Type
Marine Yoke Mount ➊
Class I, Division 2,
Class II, Division 1 & 2
Class III
Line
Voltages
Yoke Mount ➊
for General Duty
Slip-Fit Mount ➋
Class I, Division 2
Slip-Fit
Mount ➋
70
HPS 120/208/240/277 G-AM271L-MT-I/2CN
G-AM271L-MTCN
G-AM275L-MT-I/2CN G-AM275L-MTCN
70
HPS
G-AM271L-TT-I/2CN
G-AM271L-TTCN
G-AM275L-TT-I/2CN
100
HPS 120/208/240/277 G-AM371L-MT-I/2CN
G-AM371L-MTCN
G-AM375L-MT-I/2CN G-AM375L-MTCN
100
HPS
G-AM371L-TT-I/2CN
G-AM371L-TTCN
G-AM375L-TT-I/2CN
150
HPS 120/208/240/277 G-AM471L-MT-I/2CN
G-AM471L-MTCN
G-AM475L-MT-I/2CN G-AM475L-MTCN
150
HPS
G-AM471L-TT-I/2CN
G-AM471L-TTCN
G-AM475L-TT-I/2CN
120/277/347
120/277/347
120/277/347
G-AM275L-TTCN
G-AM375L-TTCN
G-AM475L-TTCN
70
PSMH 120/208/240/277 G-AM271H-MT-I/2CN
G-AM271H-MTCN
G-AM275H-MT-I/2CN G-AM275H-MTCN
70
PSMH
G-AM271H-TT-I/2CN
G-AM271H-TTCN
G-AM275H-TT-I/2CN G-AM275H-TTCN
100
PSMH 120/208/240/277 G-AM371H-MT-I/2CN
G-AM371H-MTCN
G-AM375H-MT-I/2CN G-AM375H-MTCN
100
PSMH
G-AM371H-TT-I/2CN
G-AM371H-TTCN
G-AM375H-TT-I/2CN G-AM375H-TTCN
150
PSMH 120/208/240/277 G-AM471H-MT-I/2CN
G-AM471H-MTCN
G-AM475H-MT-I/2CN G-AM475H-MTCN
150
PSMH
G-AM471H-TT-I/2CN
G-AM471H-TTCN
G-AM475H-TT-I/2CN G-AM475H-TTCN
120/277/347
120/277/347
120/277/347
Operating
Amps
Total
Watts
0.82
0.48
0.41
0.36
0.30
0.21
94
94
94
94
94
94
1.15
0.67
0.60
0.52
0.39
0.31
130
130
130
130
130
135
1.70
0.95
0.85
0.72
0.56
0.47
188
188
188
188
188
188
Line
Type of
Starting
Voltage
Ballast
Amps
70 Watt Pulse Start Metal Halide
120
HX-HPF
0.80
208
HX-HPF
0.50
240
HX-HPF
0.43
277
HX-HPF
0.39
347
HX-HPF
0.20
480
HX-HPF
0.26
100 Watt Pulse Start Metal Halide
120
HX-HPF
1.20
208
HX-HPF
0.70
240
HX-HPF
0.61
277
HX-HPF
0.55
347
HX-HPF
0.40
480
HX-HPF
0.30
150 Watt Pulse Start Metal Halide
120
HX-HPF
1.75
208
HX-HPF
1.30
240
HX-HPF
0.85
277
HX-HPF
0.77
347
Super C.W.A.
0.65
480
Super C.W.A.
0.45
Operating
Amps
Total
Watts
0.85
0.52
0.44
0.39
0.28
0.23
95
95
95
95
88
95
1.15
0.70
0.58
0.50
0.40
0.35
130
130
130
130
129
140
1.60
1.00
0.80
0.70
0.55
0.42
188
188
188
188
185
185
T Numbers and Temperature Ratings of “Classified Duty”
Lamp Watts
70
100
150
T Rating
T3
T2C
T2
Ambient Temperature (°F/°C)
104/40
104/40
104/40
T Rating Temperature Range (°F/°C)
358-392/181-200
421-446/216-230
538-572/281-300
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
Lighting
➊ Adjustable yoke mounts directly or with adapters.
➋ Internally wired, adjustable slip-fit mount for 2” or 2-1/2” pipe.
V CSA Certification only.
Lighting: Enclosed and Gasketed — Floodlight
Electrical Specifications
Line
Type of
Starting
Voltage
Ballast
Amps
70 Watt High Pressure Sodium
120
HX-HPR
0.90
208
HX-HPR
0.50
240
HX-HPR
0.44
277
HX-HPR
0.35
347
HX-HPF
0.30
480
HX-HPR
0.21
100 Watt High Pressure Sodium
120
HX-HPR
1.30
208
HX-HPR
0.76
240
HX-HPR
0.66
277
HX-HPR
0.60
347
HX-HPF
0.45
480
HX-HPR
0.33
150 Watt High Pressure Sodium
120
HX-HPR
2.00
208
HX-HPR
1.16
240
HX-HPR
1.00
277
HX-HPR
0.85
347
HX-HPF
0.52
480
HX-HPR
0.50
1151
Areamaster™ 100 Wide-Beam Floodlights
70 W, 100 W, 150 W HPS; 70 W, 100 W, 150 PSMH
For general, marine and hazardous locations.
Mounting Fittings and Accessories
Description
Catalog Number
G-AM-8-CA
Pipe or Wall Mount Bracket — Used with G-AM-8-CA. Clamps to 1” to 2-1/2”
pipe, vertical or horizontal, or mounts on flat surfaces. Includes U-bolt and crossarm
bracket bolts. Malleable iron, zinc plated, chromate sealed, with architectural bronze
polyester finish.
G-AM-8-WB
Poletop Slip-Fitter — 1-1/2” or 2” pipe size poletop tenons. Includes floodlight
yoke bolt, 3 locking bolts, and cord grip. Body is malleable iron—zinc plated,
chromate sealed, with cast aluminum cap. Assembly has architectural bronze
polyester finish.
G-SF20
Locking-Type Photocontrol Receptacle — For NEMA type photocontrol, with
installation hardware and instructions. Should not be mounted on Class I Division 2
units.
G-1PCR
Vandal Shield — UV stabilized polycarbonate, with installation hardware and
instructions.
G-AM-2-VS
Wire Guard — Mounts to lens door with screws furnished. Zinc plated.
G-AM-2-G
Top Visor — Easy to install with hardware supplied. Aluminum, with architectural
bronze polyester finish.
G-AM-2-V
Lighting
Lighting: Enclosed and Gasketed — Floodlight
Crossarm Mounting Bracket — Has 180° horizontal adjustment—degree-marked.
Facilitates mounting floodlight to crossarm or other flat surface, or to G-AM-8-WB.
Includes floodlight yoke bolts. Malleable iron, zinc plated, chromate sealed,
architectural bronze POLYESTER finish.
1152
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
Areamaster™ 100 Wide-Beam Floodlight Dimensions
70 W, 100 W, 150 W HPS; 70 W, 100 W, 150 PSMH
For general, marine and hazardous locations.
Yoke Mount
Pipe or Wall Mount Bracket
Wire Guard
Lighting: Enclosed and Gasketed — Floodlight
Crossarm Mounting Bracket
Pole Mount
Poletop Slip-Fitter
Top Visor
Lighting
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
1153
Areamaster™ 100 Wide-Beam Floodlight Photometric Data
70 W, 100 W, 150 W HPS; 70 W, 100 W, 150 PSMH
For general, marine and hazardous locations.
Catalog Number
G-AM471L-MT
G-AM371L-MT
G-AM271L-MT
Lamp
Photometric Data
Watts
Lumens
Bulb
Light Center Lgth.
Base
150
16,000
E-23-1/2 Clear
5”
Mogul Screw
Watts
Lumens
Bulb
Light Center Lgth.
Base
100
9500
E-23-1/2 Clear
5”
Mogul Screw
Watts
Lumens
Bulb
Light Center Lgth.
Base
70
5800
E-23-1/2 Clear
5”
Mogul Screw
Total Footcandle Value ‡
150 Watt High Pressure Sodium - Clear 16,000 Lumens
Lighting: Enclosed and Gasketed — Floodlight
141°
115°
8148
50.9%
5155
8552
53.5%
141°
115°
4838
50.9%
3061
5062
53.3%
141°
113°
2982
51.4%
2025
3124
53.9%
Footcandles for Iso-FTC Lines
Ratio of Distance to Height
1.50 C 2.00 D 2.50 E
Lamp Mounting
Watts Height (Ft/M) 0.63 A
1.00 B
10/3.0
31.25
18.23
8.06
3.41
1.63
0.86
0.38
20/6.1
7.81
4.56
2.02
0.85
0.41
0.22
0.10
150
Lighting
Horizontal Spread
Vertical Spread
Beam Lumens
Beam Efficiency
Max. CP.
Total Lumens
Total Efficiency
Horizontal Spread
Vertical Spread
Beam Lumens
Beam Efficiency
Max. CP.
Total Lumens
Total Efficiency
Horizontal Spread
Vertical Spread
Beam Lumens
Beam Efficiency
Max. CP.
Total Lumens
Total Efficiency
100
70
3.00 F
3.75 G
30/9.1
3.47
2.03
0.90
0.38
0.18
0.10
0.04
10/3.0
18.44
10.76
4.76
2.01
0.96
0.51
0.22
20/6.1
4.61
2.69
1.19
0.50
0.24
0.13
0.06
30/9.1
2.05
1.20
0.53
0.22
0.11
0.06
0.02
10/3.0
11.25
6.56
2.90
1.23
0.59
0.31
0.14
20/6.1
2.81
1.64
0.73
0.31
0.15
0.08
0.04
30/9.1
1.25
0.73
0.32
0.14
0.06
0.04
0.01
‡ Photometric charts available upon request.
* (i.e. ratio of distance to height. Example: @ 15'/4.6 m mounting height, 1 means 15'/4.6 m, 2 means 30'/9.1 m, etc.)
1154
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
Areamaster™ 250/400 Integrally Ballasted Floodlights
70 W, 100 W, 150 W, 250 W, 400 W HPS; 175 W, 200 W, 250 W, 320 W, 400 W PSMH.
175 W, 250 W, 400 W MH V
NEC: For general, marine and hazardous
locations
Class I, Division 2, Groups A, B, C, D
Class I, Zone 2, AEx nR, Groups IIA, IIB, IIC
CEC V: For general, marine and hazardous
locations
Class I, Division 2, Groups A, B, C, D
Class I, Zone 2, Ex nR, Groups IIA, IIB, IIC
Class II, Division 1 and 2, Groups E, F, G
Class III
NEC/CEC:
IP66
Marine type electric fixtures, outside type
(salt water)
Applications
• Powerful, efficient weatherproof lighting for medium and large
areas such as:
— Shopping malls
— Parking lots
— Sports areas
— New-car lot lighting
— Security lighting
— Industrial process lighting
Features
• Compact in size, attractively styled contemporary design,
rugged and dependable.
• Easy to install and service.
• A wide range of ballasts and voltages are available for both
domestic and export applications.
• Integral ballast.
• One-piece housing.
• One-piece lens cover. Secured by four 1/4” Dia. captive
stainless steel slotted hex-head bolts.
• Thermal shock and impact resistant glass lens.
• Heavy duty, high temperature silicone rubber gasket, firmly
seated.
• Heavy duty mogul-base porcelain socket with heavy gauge
brass, nickel-plated, double lamp-grip screw shell and springloaded center contact.
• Compound parabolic, double segment, finished aluminum
reflector for optimum efficiency.
• Mounting choice:
(1) Yoke mount, zinc plated steel yoke with architectural bronze
polyester finish
(2) Pole mount, built-in slip-fitter, for internal wiring, adjustable
laterally and vertically, slip fits 2” or 2-1/2” pipe, architectural
bronze polyester finish
• Cool operating temperatures translate into long luminaire life.
Projected Area: 1.9 Sq. Ft.
Dimensions in Inches/Millimeters
Standard Materials
Lighting: Enclosed and Gasketed — Floodlight
• Ballast housing and lens door: copperfree (4/10 of 1% max.)
aluminum
• Gasket: silicone rubber
• Socket: heavy duty porcelain with heavy gauge brass shell
• Reflector: finished aluminum
• Yoke mount: zinc plated steel
• Bolts: stainless steel
Standard Finishes
• Ballast housing, lens cover, yoke and pole mount: architectural
bronze polyester
• Socket: nickel-plated
Certifications and Compliances
•
•
Areamaster 250/400
— UL Standard: UL 1598, UL 1598A, UL 844
— UL Listed: E10794
Zone 2 Areamaster 250/400
— UL Standard: UL 1598, UL 1598A, UL 60079-0,
UL 60079-15
— UL Listed: E10794
Lighting
V CSA Certification only.
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
1155
Areamaster™ 250/400 Integrally Ballasted Floodlights
70 W, 100 W, 150 W, 250 W, 400 W HPS; 175 W, 200 W, 250 W, 320 W, 400 W PSMH.
175 W, 250 W, 400 W MH V
NEC: For general, marine and hazardous
locations
Class I, Division 2, Groups A, B, C, D
Class I, Zone 2, AEx nR, Groups IIA, IIB, IIC
NEC/CEC:
IP66
Marine type electric fixtures, outside type
(salt water)
CEC V: For general, marine and hazardous
locations
Class I, Division 2, Groups A, B, C, D
Class I, Zone 2, Ex nR, Groups IIA, IIB, IIC
Class II, Division 1 and 2, Groups E, F, G
Class III
“T” Numbers
Lighting
Lighting: Enclosed and Gasketed — Floodlight
Lamp
Watts
Type
70
HPS
100
HPS
150
HPS
250
HPS
400
HPS
175
PSMH
200
PSMH
250
PSMH
320
PSMH
400
PSMH
Supply Wire Temp.
(°F/°C)
140/60
167/75
194/90
167/75
194/90
221/105
185/85
221/105
230/110
167/75
194/90
221/105
221/105
257/125
194/90
221/105
230/110
167/75
185/85
221/105
185/85
221/105
230/110
185/85
221/105
221/105
239/115
NEC/CEC
Class I, Division 2,
Groups A, B, C, D
T3C
T3B
T3A
T3
T2D
T2C
T2C
T2B
T2B
350
350
T1
T1
—
T2
325
325
325
325
325
325
325
—
325
325
325
325
Ambient Temp.
(°F/°C)
104/40
131/55
149/65
104/40
131/55
149/65
104/40
131/55
149/65
104/40
131/55
149/65
104/40
122/50
104/40
131/55
149/65
104/40
131/55
149/65
104/40
131/55
149/65
104/40
131/55
104/40
131/55
CEC V
Class II, Division 1
and 2, Groups E, F, G
T3B
—
—
T3B
—
—
T3B
—
—
T3B
—
—
T3B
—
T3B
—
—
T3B
—
—
T3B
—
—
T3B
—
T3B
—
NEC/CEC
Class I, Zone 2
T6
T5
T4
T5
T4
T4
T4
T4
T3
T4
T3
T3
T3
T3
T4
T3
T3
T3
T3
T3
T3
T3
T3
T3
T3
T3
T3
“T” Numbers Represent the Maximum Lamp Temperature for Class I, Division 2 Locations and
Maximum Surface Temperature Under Dust Blanket for Class II, Division 1 Locations.
“T”
Number
T1
350
325
T2
T2A
T2B
T2C
T2D
T3
T3A
T3B
T3C
T4
T4A
T5
T6
Temp.
Range
(˚ºF)
664842
619662
574617
538572
502536
448500
421446
394419
358392
331356
322329
277320
250275
214248
187212
185
Temp.
Range
(°C)
351450
326350
301325
281300
261280
231260
216230
201215
181200
166180
161165
136160
121135
101120
86100
85
“T” Numbers Represent the Maximum Surface Temperature for Luminaries with AEx nA nR or AEx nR rating
“T” Number
T1
T2
T3
T4
T5
T6
Temp. Range (°F)
547-842
394-572
277-392
214-275
187-212
185
Temp. Range (°C)
301-450
201-300
136-200
101-135
86-100
85
V CSA Certification only.
1156
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
Areamaster™ 250/400 Integrally Ballasted Floodlights
70 W, 100 W, 150 W, 250 W, 400 W HPS; 175 W, 200 W, 250 W, 320 W, 400 W PSMH
NEC: For general, marine and hazardous
locations
Class I, Division 2, Groups A, B, C, D
Class I, Zone 2, AEx nR, Groups IIA, IIB, IIC
IP66
Line
Voltage
Marine type electric fixtures, outside type
(salt water)
For Class 1, Division 2
Classified Duty and
Marine Yoke Mount
Catalog Number ➋➌
For General Duty
Class I, Zone 2
Yoke Mounting
Catalog Number ➌
Yoke Mount
Catalog Number ➋
Slip-Fit Mount
Catalog Number ➊➋
G-AML271L-MT-I/2
—
—
G-AML271L-MT-Z2
G-AML271L-225-I/2 ➎
—
—
G-AML271L-225-Z2 ➎
480
G-AML271L-48-I/2
—
—
G-AML271L-48-Z2
120/208/240/277
G-AML371L-MT-I/2
—
—
G-AML371L-MT-Z2
Lamp
High Pressure Sodium
120/208/240/277
70 W HPS ➍
100 W HPS ➍
150 W HPS ➍
250 W HPS
400 W HPS
220 V 50 Hz
220 V 50 Hz
G-AML371L-225-I/2 ➎
—
—
G-AML371L-225-Z2 ➎
480
G-AML371L-48-I/2
—
—
G-AML371L-48-Z2
120/208/240/277
G-AML471L-MT-I/2
—
—
G-AML471L-MT-Z2
G-AML471L-225-I/2 ➎
—
—
G-AML471L-225-Z2 ➎
—
G-AML471L-48-Z2
220 V 50 Hz
480
G-AML471L-48-I/2
120/208/240/277
G-AM671L-MT-I/2
G-AM671L-MT
G-AM675L-MT
G-AM671L-MT-Z2
230 V 50 Hz
—
G-AM671L-235-I/2 ➎
G-AM671L-235 ➎
G-AM675L-235 ➎
G-AM671L-235-Z2 ➏
480
G-AM671L-48-I/2
G-AM671L-48
G-AM675L-48
G-AM671L-48-Z2
120/208/240/277
G-AM771L-MT-I/2
G-AM771L-MT
G-AM775L-MT
G-AM771L-MT-Z2
G-AM771L-235-I/2 ➏
G-AM771L-235 ➏
G-AM775L-235 ➏
G-AM771L-235-Z2 ➏
480
G-AM771L-48-I/2
G-AM771L-48
G-AM775L-48
G-AM771L-48-Z2
120/208/240/277
G-AM571P-MT-I/2
G-AM571P-MT
G-AM575P-MT
G-AM571P-MT-Z2
480
230 V 50 Hz
Pulse Start Metal Halide
175 W PSMH
200 W PSMH
G-AM571P-48
G-AM575P-48
G-AM571P-48-Z2
G-AM2071P-MT-I/2
G-AM2071P-MT
G-AM2075P-MT
G-AM2071P-MT-Z2
480
G-AM2071P-48-I/2
G-AM2071P-48
G-AM2075P-48
G-AM2071P-48-Z2
120/208/240/277
G-AM671P-MT-I/2
G-AM671P-MT
G-AM675P-MT
G-AM671P-MT-Z2
G-AM671P-235-I/2 ➏
G-AM671P-235 ➏
G-AM675P-235 ➏
G-AM671P-235-Z2 ➏
G-AM671P-48-I/2
G-AM671P-48
G-AM675P-48
G-AM671P-48-Z2
G-AM3271P-MT-I/2
G-AM3271P-MT
230 V 50 Hz
480
G-AM3275P-MT
G-AM3271P-MT-Z2
G-AM3271P-235-I/2 ➏ G-AM3271P-235 ➏
G-AM3275P-235 ➏
G-AM3271P-235-Z2 ➏
480
G-AM3271P-48-I/2
G-AM3271P-48
G-AM3275P-48
G-AM3271P-48-Z2
120/208/240/277
G-AM771P-MT-I/2
G-AM771P-MT
G-AM775P-MT
G-AM771P-MT-Z2
G-AM771P-235-I/2 ➏
G-AM771P-235 ➏
G-AM775P-235 ➏
G-AM771P-235-Z2 ➏
G-AM771P-48-I/2
G-AM771P-48
G-AM775P-48
G-AM771P-48-Z2
120/208/240/277
320 W PSMH
400 W PSMH
230 V 50 Hz
230 V 50 Hz
480
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
1157
Lighting
➊ Slip-fits 2” or 2-1/2” pipe-size tenons.
➋ Add suffix -E to catalog number if provision for quartz emergency option is desired. Furnished with socket installed and pre-wired.
➌ Quartz emergency option NOT available for Class I, Division 2 or Class I, Zone 2 fixtures. Classified duty floodlights have 1/2” N.P.T tapped hub for power entry.
Use 221 °F/105 °C supply wire.
➍ For Hot Restrike Option, add suffix –R.
➎ For 120 V 50 Hz change -225 to -125, or for 240 V 50 Hz change -225 to -245.
➏ For 120 V 50 Hz change -235 to -125.
Lighting: Enclosed and Gasketed — Floodlight
250 W PSMH
G-AM571P-48-I/2
120/208/240/277
Areamaster™ 250/400 Integrally Ballasted Floodlights V
70 W, 100 W, 150 W, 250 W, 400 W HPS; 175 W, 200 W, 250 W, 320 W, 400 W PSMH;
175 W, 250 W, 400 W MH
CEC V: For general, marine and hazardous
locations
Class I, Division 2, Groups A, B, C, D
Class I, Zone 2, Ex nR, Groups IIA, IIB, IIC
Class II, Division 1 and 2, Groups E, F, G
Class III
Line
Voltage
Lamp
High Pressure Sodium
120/277/347
70 W HPS ➍
100 W HPS ➍
150 W HPS ➍
250 W HPS
400 W HPS
Lighting
Lighting: Enclosed and Gasketed — Floodlight
400 W PSMH
For Class 1, Division 2
Classified Duty and
Marine Yoke Mount
Catalog Number ➋➌
For General Duty
Yoke Mount
Catalog Number ➋
Slip-Fit Mount
Catalog Number ➊➋
Class I, Zone 2
Yoke Mounting
Catalog Number ➌
G-AML271L-TT-I/2
—
—
G-AML271L-TT-Z2
220 V 50 Hz
G-AML271L-225-I/2 ➎
—
—
G-AML271L-225-Z2 ➎
600 ➐
120/277/347
G-AML271L-C7-I/2
—
—
G-AML271L-C7-Z2
G-AML371L-TT-I/2
—
—
G-AML371L-TT-Z2
220 V 50 Hz
G-AML371L-225-I/2 ➎
—
—
G-AML371L-225-Z2 ➎
600 ➐
120/277/347
G-AML371L-C7-I/2
—
—
G-AML371L-C7-Z2
G-AML471L-TT-I/2
—
—
G-AML471L-TT-Z2
220 V 50 Hz
G-AML471L-225-I/2 ➎
—
—
G-AML471L-225-Z2 ➎
600 ➐
120/277/347
G-AML471L-C7-I/2
—
—
G-AML471L-C7-Z2
G-AM671L-TT-I/2
G-AM671L-TT
G-AM675L-TT
G-AM671L-TT-Z2
230 V 50 Hz
G-AM671L-235-I/2 ➎
G-AM671L-235 ➎
G-AM675L-235 ➎
G-AM671L-235-Z2 ➏
600 ➐
120/277/347
G-AM671L-C7-I/2
G-AM671L-C7
G-AM675L-C7
G-AM671L-C7-Z2
G-AM771L-TT-I/2
G-AM771L-TT
G-AM775L-TT
G-AM771L-TT-Z2
230 V 50 Hz
G-AM771L-235-I/2 ➏
G-AM771L-235 ➏
G-AM775L-235 ➏
G-AM771L-235-Z2 ➏
G-AM771L-C7-I/2
G-AM771L-C7
G-AM775L-C7
G-AM771L-C7-Z2
G-AM571P-TT-I/2
G-AM2071P-TT-I/2
G-AM671P-TT-I/2
G-AM571P-TT
G-AM2071P-TT
G-AM671P-TT
G-AM575P-TT
G-AM2075P-TT
G-AM675P-TT
G-AM571P-TT-Z2
G-AM2071P-TT-Z2
G-AM671P-TT-Z2
G-AM671P-235-I/2 ➏
G-AM3271P-TT-I/2
G-AM671P-235 ➏
G-AM3271P-TT
G-AM675P-235 ➏
G-AM3275P-TT
G-AM671P-235-Z2 ➏
G-AM3271P-TT-Z2
600 ➐
Pulse Start Metal Halide
175 W PSMH
120/277/347
200 W PSMH
120/277/347
120/277/347
250 W PSMH
230 V 50 Hz
320 W PSMH
IP66
Marine type electric fixtures, outside type
(salt water)
120/277/347
230 V 50 Hz
120/277/347
G-AM3271P-235-I/2 ➏ G-AM3271P-235 ➏
G-AM771P-TT-I/2
G-AM771P-TT
G-AM3275P-235 ➏
G-AM775P-TT
G-AM3271P-235-Z2 ➏
G-AM771P-TT-Z2
230 V 50 Hz
G-AM771P-235-I/2 ➏
G-AM771P-235 ➏
G-AM775P-235 ➏
G-AM771P-235-Z2 ➏
120/277/347
G-AM571H-TT-I/2
G-AM571H-TT
G-AM575H-TT
G-AM571H-TT-Z2
220 V 50 Hz
Metal Halide
175 W MH
250 W MH
400 W MH
G-AM571H-225-I/2 ➎
G-AM571H-225 ➎
G-AM575H-225 ➎
G-AM571H-225-Z2 ➎
600 ➐
G-AM571H-C7-I/2
G-AM571H-C7
G-AM575H-C7
G-AM571H-C7-Z2
120/277/347
G-AM671H-TT-I/2
G-AM671H-TT
G-AM675H-TT
G-AM671H-TT-Z2
220 V 50 Hz
G-AM671H-225-I/2 ➎
G-AM671H-225 ➎
G-AM675H-225 ➎
G-AM671H-225-Z2 ➎
600 ➐
G-AM671H-C7-I/2
G-AM671H-C7
G-AM675H-C7
G-AM671H-C7-Z2
120/277/347
G-AM771H-TT-I/2
G-AM771H-TT
G-AM775H-TT
G-AM771H-TT-Z2
220 V 50 Hz
G-AM771H-225-I/2 ➎
G-AM771H-225 ➎
G-AM775H-225 ➎
G-AM771H-225-Z2 ➎
G-AM771H-C7-I/2
G-AM771H-C7
G-AM775H-C7
G-AM771H-C7-Z2
600 ➐
➊ Slip-fits 2” or 2-1/2” pipe-size tenons.
➋ Add suffix -E to catalog number if provision for quartz emergency option is desired. Furnished with socket installed and pre-wired.
➌ Quartz emergency option NOT available for Class I, Division 2 or Class I, Zone 2 fixtures. Classified duty floodlights have 1/2” N.P.T tapped hub for power entry.
Use 221 °F/105 °C supply wire.
➍ For Hot Restrike Option, add suffix –R.
➎ For 120 V 50 Hz change -225 to -125, or for 240 V 50 Hz change -225 to -245.
➏ For 120 V 50 Hz change -235 to -125.
➐ Supplied complete with CWI Isolated Secondary Ballast for 600 Vac. For 208, 240 or 480 V applications, change the -C7 suffix to -C2, -C3 or -C6 as required.
V CSA Certification only.
1158
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
Areamaster™ 250/400 Integrally Ballasted Floodlights
70 W, 100 W, 150 W, 250 W, 400 W HPS; 175 W, 200 W, 250 W, 320 W, 400 W PSMH.
175 W, 250 W, 400 W MH V
Dimensions
Description
Catalog Numbers
Crossarm Mounting Bracket
Has 180° horizontal adjustment — degree marked. Facilitates mounting
floodlight to crossarm or other flat surface, or to G-AM-8-WB. Includes
floodlight yoke bolts. Malleable iron, zinc plated, chromate sealed,
architectural bronze polyester finish.
G-AM-8-CA
Used with G-AM-8-CA. Clamps to 1” to 2-1/2” pipe, vertical or horizontal,
or mounts on flat surfaces. Includes U-bolt and crossarm bracket bolts.
Malleable iron, zinc plated, chromate sealed, with architectural bronze polyster
finish.
G-AM-8-WB
Slip-fits 1-1/2” or 2” pipe size poletop tenons. Includes floodlight yoke bolts,
3 locking bolts, and cord grip. Body is malleable iron-zinc plated, chromate
sealed, with cast aluminum cap. Assembly has architectural bronze polyester
finish.
G-SF20
Pipe or Wall Mount Bracket
Poletop Slip-Fitter
Locking-Type Photocontrol Receptacle
For NEMA type photocontrol, with installation hardware and instructions.
Should not be mounted on Class I, Division 2/Class 1, Zone 2 units.
G-1PCR
UV stabilized polycarbonate, with installation hardware and instructions.
G-AM-6-VS
Easy to install with hardware supplied. Aluminum, with architectural bronze
POLYESTER finish.
G-AM-6-V
Vandal Shield
Replacement Lens
604249003
Lighting: Enclosed and Gasketed — Floodlight
Top Visor
Replacement Lens Frame Assembly
Complete with Lens
59607383002
Lighting
V CSA Certification only.
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
1159
Areamaster™ 250/400 Integrally Ballasted Floodlights
70 W, 100 W, 150 W, 250 W, 400 W HPS; 175 W, 200 W, 250 W, 320 W, 400 W PSMH.
175 W, 250 W, 400 W MH V
Lighting
Lighting: Enclosed and Gasketed — Floodlight
NEC: For general, marine and hazardous
locations
Class I, Division 2, Groups A, B, C, D
Class I, Zone 2, AEx nR, Groups IIA, IIB, IIC
Line
Type of
Frequency
Voltage
Ballast
70 Watt High Pressure Sodium
120
60
HX-HPF
208
60
HX-HPF
240
60
HX-HPF
277
60
HX-HPF
60
HX-HPF
347V
480
60
HX-HPF
120
50
HX-HPF
220
50
HX-HPF
240
50
HX-HPF
100 Watt High Pressure Sodium
120
60
HX-HPF
208
60
HX-HPF
240
60
HX-HPF
277
60
HX-HPF
60
HX-HPF
347V
480
60
HX-HPF
120
50
HX-HPF
220
50
HX-HPF
240
50
HX-HPF
150 Watt High Pressure Sodium
120
60
HX-HPF
208
60
HX-HPF
240
60
HX-HPF
277
60
HX-HPF
60
HX-HPF
347V
480
60
HX-HPF
120
50
HX-HPF
220
50
HX-HPF
240
50
HX-HPF
250 Watt High Pressure Sodium
120
60
CWA
208
60
CWA
240
60
CWA
277
60
CWA
60
CWA
347V
480
60
CWA
120
50
CWA
230
50
CWA
400 Watt High Pressure Sodium
120
60
CWA
208
60
CWA
240
60
CWA
277
60
CWA
60
CWA
347V
480
60
CWA
120
50
CWA
230
50
CWA
175 Watt Pulse Start Metal Halide
120
60
Super CWA
208
60
Super CWA
240
60
Super CWA
277
60
Super CWA
60
Super CWA
347V
480
60
Super CWA
200 Watt Pulse Start Metal Halide
120
60
Super CWA
208
60
Super CWA
240
60
Super CWA
277
60
Super CWA
60
Super CWA
347V
480
60
Super CWA
CEC V: For general, marine and hazardous
locations
Class I, Division 2, Groups A, B, C, D
Class I, Zone 2, Ex nR, Groups IIA, IIB, IIC
Class II, Division 1 and 2, Groups E, F, G
Class III
Starting
Amps
Operating
Amps
Total
Watts
0.90
0.50
0.44
0.35
0.30
0.21
1.08
0.59
0.54
0.82
0.48
0.41
0.36
0.30
0.21
0.81
0.49
0.45
94
94
94
94
93
94
97
97
97
1.30
0.76
0.66
0.60
0.45
0.33
0.90
0.50
0.45
1.15
0.67
0.60
0.52
0.39
0.31
1.20
0.65
0.60
130
130
130
130
130
135
130
130
130
2.00
1.15
1.00
0.85
0.52
0.50
1.50
0.85
0.75
1.70
0.95
0.85
0.72
0.56
0.47
1.60
0.90
0.80
188
188
188
188
188
189
188
188
188
2.00
1.20
1.00
0.85
0.60
0.40
1.85
0.95
2.50
1.50
1.30
1.10
0.93
0.65
2.75
1.44
295
295
295
295
295
295
300
300
3.30
1.80
1.60
1.40
1.00
0.80
3.70
1.85
3.80
2.20
1.90
1.70
1.32
1.00
4.00
2.00
465
465
465
465
464
465
465
465
0.90
0.50
0.35
0.30
0.25
0.25
1.78
1.08
0.89
0.76
0.65
0.50
199
199
199
199
208
213
2.10
1.15
1.10
0.75
0.25
0.35
2.00
1.25
1.00
0.85
0.70
0.50
235
235
235
235
232
237
NEC/CEC:
IP66
Marine type electric fixtures, outside type
(salt water)
Line
Type of
Starting
Frequency
Voltage
Ballast
Amps
250 Watt Pulse Start Metal Halide
120
60
Super CWA
1.90
208
60
Super CWA
1.10
240
60
Super CWA
0.96
277
60
Super CWA
0.85
60
Super CWA
0.62
347V
480
60
Super CWA
0.45
120
50
Super CWA
1.90
230
50
Super CWA
1.00
320 Watt Pulse Start Metal Halide
120
60
Super CWA
2.60
208
60
Super CWA
1.50
240
60
Super CWA
1.30
277
60
Super CWA
1.15
60
Super CWA
0.70
347V
480
60
Super CWA
0.60
120
50
Super CWA
2.28
230
50
Super CWA
1.14
400 Watt Pulse Start Metal Halide
120
60
Super CWA
3.50
208
60
Super CWA
2.00
240
60
Super CWA
1.25
277
60
Super CWA
1.50
60
Super CWA
1.10
347V
480
60
Super CWA
0.90
120
50
Super CWA
3.17
230
50
Super CWA
1.65
175 Watt Metal Halide V
120
60
CWA
1.30
208
60
CWA
0.75
240
60
CWA
0.65
277
60
CWA
0.55
347
60
CWA
0.50
480
60
CWA
0.35
120
50
CWA
1.70
220
50
CWA
0.80
250 Watt Metal Halide V
120
60
CWA
1.20
208
60
CWA
0.65
240
60
CWA
0.60
277
60
CWA
0.50
347
60
CWA
0.80
480
60
CWA
0.30
120
50
CWA
2.00
220
50
CWA
0.94
400 Watt Metal Halide V
120
60
CWA
3.25
208
60
CWA
1.90
240
60
CWA
1.65
277
60
CWA
1.40
347
60
CWA
1.20
480
60
CWA
0.85
120
50
CWA
2.70
220
50
CWA
1.50
Operating
Amps
Total
Watts
2.50
1.45
1.25
1.10
0.90
0.60
2.60
1.35
288
288
288
288
291
285
285
285
3.25
1.90
1.65
1.40
1.10
0.80
3.05
1.60
368
368
368
368
368
368
365
365
4.00
2.30
2.00
1.75
1.35
1.00
3.90
2.00
454
454
454
454
452
454
454
454
1.80
1.10
0.90
0.80
0.65
0.45
1.90
1.10
213
213
213
213
210
213
210
210
2.60
1.50
1.30
1.12
0.90
0.65
2.50
1.30
295
295
295
295
295
298
285
285
4.00
2.30
2.00
1.75
1.40
1.00
4.10
2.20
458
458
458
458
460
462
480
480
V CSA Certification only.
1160
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
Areamaster™ 250/400 Integrally Ballasted Floodlights
70 W, 100 W, 150 W, 250 W, 400 W HPS; 175 W, 200 W, 250 W, 320 W, 400 W PSMH.
175 W, 250 W, 400 W MH V
Distance in terms of mounting height ◊
Typical Footcandle Values
Ft. Cdles for Iso-Footcandle Lines
Mtg. Ht.
400W HPS
60’/18.3m
50’/15.2m
40’/12.2m
30’/9.1m
20’/6.1m
A
B
C
D
E
F
3.27
4.74
7.65
13.10
28.22
2.74
4.00
6.28
10.92
25.55
1.82
2.90
4.38
7.83
17.37
0.92
1.37
2.27
3.47
7.28
0.37
0.52
0.82
1.45
3.46
0.18
0.27
0.43
0.77
1.82
400W MH V
60’/18.3m
50’/15.2m
40’/12.2m
30’/9.1m
20’/6.1m
2.32
3.32
5.48
9.79
17.26
1.66
2.32
3.62
7.80
14.60
1.00
1.49
2.32
3.98
9.30
0.58
0.76
1.33
2.16
5.31
0.33
0.48
0.75
1.33
3.15
0.17
0.25
0.36
0.68
1.49
0.37
0.54
0.84
1.49
3.53
0.19
0.28
0.40
0.76
1.67
For 400W PSMH multiply FC values by 1.29; for 320W PSMH use 0.97.
400W PSMH
60’/18.3m
2.60
50’/15.2m
3.72
40’/12.2m
6.14
30’/9.1m
10.96
20’/6.1m
19.33
1.86
2.60
4.05
8.74
16.35
1.12
1.66
2.60
4.46
10.41
0.65
0.85
1.49
2.42
5.94
Ft. Cdles for Iso-Footcandle Lines
Distance in terms of mounting height ◊
Mtg. Ht.
70W HPS
10’/3.0m
20’/6.1m
30’/9.1m
G
H
I
J
K
L
10.00
2.50
1.00
5.00
1.00
0.50
2.50
0.50
0.25
1.00
0.25
0.10
0.50
0.10
0.05
0.25
0.05
0.02
For 100W HPS lamps, multiply FC values by 1.5. For 150W HPS lamps, multiply FC values by 2.5.
A
B
C
D
E
F
1.96
2.84
4.58
7.85
16.90
1.64
2.40
3.76
6.54
15.30
1.09
1.74
2.62
4.69
10.40
0.55
0.82
1.36
2.08
4.36
0.22
.031
0.49
0.87
2.07
0.11
0.16
0.26
0.46
1.09
250W MH V
60’/18.3m
50’/15.2m
40’/12.2m
30’/9.1m
20’/6.1m
1.40
2.00
3.30
5.90
10.40
1.00
1.40
2.18
4.70
8.80
0.60
0.90
1.40
2.40
5.60
0.35
0.46
0.80
1.30
3.20
0.20
0.29
0.45
0.80
1.90
0.10
0.15
0.22
0.41
0.90
For 175W MH lamps, multiply FC values by 0.68. For 175W PSMH Lamps 0.85; for 200W PSMH
use 1.03; for 250W PSMH use 1.22.
Distance in terms of mounting height ◊
250W PSMH
60’/18.3m
1.90
50’/15.2m
2.72
40’/12.2m
4.48
30’/9.1m
8.00
20’/6.1m
14.40
1.63
1.90
2.96
6.40
11.97
0.82
1.22
1.90
3.26
7.61
0.48
0.63
1.09
1.76
4.35
0.27
0.39
0.61
1.09
2.58
0.14
0.20
0.30
0.55
1.22
Lighting: Enclosed and Gasketed — Floodlight
Distance in terms of mounting height ◊
Ft. Cdles for Iso-Footcandle Lines
Mtg. Ht.
250W HPS
60’/18.3m
50’/15.2m
40’/12.2m
30’/9.1m
20’/6.1m
For 175W MH lamps, multiply FC values by 0.68. For 175W PSMH Lamps 0.85; for 200W PSMH
use 1.03; for 250W PSMH use 1.22.
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
Lighting
(i.e., ratio of distance to height. Example: @ 20’/6.1 m mounting height, 1 means 20’/6.1 m; 2 means 40’/12.2 m, etc.
Photometric charts available on request.
V CSA Certification only.
1161
Areamaster™ 1000 Floodlights
Integrally Ballasted. 1000 W HPS; 1000 W, 1500 W MH
For general or hazardous locations.
NEC: For general, marine and hazardous
locations
Class I, Division 2, Groups A, B, C, D
CEC V: For general, marine and hazardous
locations
Class I, Division 2, Groups A, B, C, D
Class I, Zone 2, Ex nR, Groups IIA, IIB, IIC
Applications
• Powerful, efficient weatherproof floodlights for large areas
such as:
— Shopping malls
— Industrial complexes
— Ship loading areas
— Mining sites
— Parking lots
— Sports areas
• Suitable for wet locations.
Lighting
Lighting: Enclosed and Gasketed — Floodlight
Features
• Highly efficient, integrally ballasted floodlight. Has compact,
lightweight, yet rugged diecast aluminum construction.
Combines architecturally beautiful design with rugged
dependability, simple installation and maintenance.
• Easy to install and service.
• A wide range of ballasts and voltages are available for both
domestic and export applications.
• Integral ballast.
• One-piece housing.
• One-piece lens cover. Secured by four 1/4” Dia. captive
stainless steel slotted hex-head bolts.
• Thermal shock and impact resistant glass lens.
• Heavy duty, high temperature silicone rubber gasket, firmly
seated.
• Heavy duty mogul-base porcelain socket with heavy gauge
brass, nickel-plated, double lamp-grip screw shell and springloaded center contact.
• Compound parabolic, double segment, finished aluminum
reflector for optimum efficiency.
• Mounting choice:
(1) Yoke mount, zinc plated steel yoke with architectural bronze
polyester finish.
(2) Pole mount, built-in slip-fitter, for internal wiring, adjustable
laterally and vertically, slip fits 2” or 2-1/2” pipe, architectural
bronze polyester finish.
• Cool operating temperatures for Class I, Division 2 fixtures
translate into long luminaire life.
Yoke
Slip-Fit
Projected Area: 3.36 Sq. Ft.
Standard Materials
• Ballast housing and lens door: copperfree (4/10 of 1% max.)
aluminum
• Gasket: silicone rubber
• Socket: heavy duty porcelain with heavy gauge brass shell
• Reflector: finished aluminum
• Yoke mount: zinc plated steel
• Bolts: stainless steel
Standard Finishes
• Ballast housing, lens cover, yoke and pole mount: architectural
bronze polyester
• Socket: nickel-plated
Certifications and Compliances
• UL Standard: UL 1598, UL 844
• UL Listed: E10794
V CSA Certification only.
1162
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
Areamaster™ 1000 Floodlights
Integrally Ballasted. 1000 W HPS; 1000 W, 1500 W MH
For general or hazardous locations.
NEC: For general, marine and hazardous
locations
Class I, Division 2, Groups A, B, C, D
Lamp
Watts ➍
Line
Voltage ➍
CEC V: For general, marine and hazardous
locations
Class I, Division 2, Groups A, B, C, D
Class I, Zone 2, Ex nR, Groups IIA, IIB, IIC
NEC/CEC
Class 1, Division 2
Classified Duty and
Marine Yoke Mount
Catalog Number ➌
General Duty
CEC
Class I, Zone 2, Ex nR
Classified Duty and
Marine Yoke Mount
Catalog Number ➌
NEC/CEC
Yoke Mount
Catalog Number ➋
NEC/CEC
Slip-Fit Mount
Catalog Number ➊➋
G-AM861L-MT-I/2
G-AM861L-MT
G-AM865L-MT
G-AM861L-MT-Z V
G-AM861L-TT-I/2 V
G-AM861L-TT V
G-AM865L-TT V
G-AM861L-TT-Z V
High Pressure Sodium
1000
120/208/240/277
1000
120/277/347
1000
480
G-AM861L-48-I/2
G-AM861L-48
G-AM865L-48
G-AM861L-48-Z V
1000
120/208/240/277
G-AM861H-MT-I/2
G-AM861H-MT
G-AM865H-MT
G-AM861H-MT-Z V
1000
120/277/347
G-AM861H-TT-I/2 V
G-AM861H-TT V
G-AM865H-TT V
G-AM861H-TT-Z V
1000
480
G-AM861H-48-I/2
G-AM861H-48
G-AM865H-48
G-AM861H-48-Z V
1500
120/208/240/277
—
G-AM961H-MT
G-AM965H-MT
—
1500
480
—
G-AM961H-48
G-AM965H-48
—
Metal Halide
Dimensions
Lighting: Enclosed and Gasketed — Floodlight
Slip-Fit Mount
Yoke Mount
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
Lighting
➊ Slip-fits 2” or 2-1/2” pipe-size tenons.
➋ Add suffix -E to catalog number if provision for bayonet type quartz emergency option is desired. Furnished with socket installed and pre-wired. Quartz
emergency option NOT available for Class I, Division 2 fixtures.
➌ Classified duty floodlights have 3/4” N.P.T. tapped hub for power entry.
➍ Additional ballast types and voltages are available. Contact your local sales representative.
V CSA Certification only.
1163
Areamaster™ 1000 Floodlight Mounting Fittings and Accessories
Integrally Ballasted. 1000 W HPS; 1000 W, 1500 W MH
For general or hazardous locations.
Dimensions
Description
Catalog Numbers
Crossarm Mounting Bracket
Has 180° horizontal adjustment — degree marked. Facilitates mounting
floodlight to crossarm or other flat surface, or to G-AM-8-WB. Includes
floodlight yoke bolts. Malleable iron, zinc plated, chromate sealed,
architectural bronze polyester finish.
G-AM-8-CA
Used with G-AM-8-CA. Clamps to 1” to 2-1/2” pipe, vertical or horizontal,
or mounts on flat surfaces. Includes U-bolt and crossarm bracket bolts.
Malleable iron, zinc plated, chromate sealed, with architectural bronze polyster
finish.
G-AM-8-WB
Slip-fits 2” or 2-1/2” poletop tenons. Includes floodlight yoke bolts, 3 locking
bolts, and cord grip. Malleable iron, zinc plated, chromate sealed, with
architectural bronze POLYESTER finish.
G-AM-8-SF
Pipe or Wall Mount Bracket
Poletop Slip-Fitter
Locking-Type Photocontrol Receptacle
For NEMA type photocontrol, with installation hardware and instructions.
Should not be mounted on Class I, Division 2 units.
G-1PCR
UV stabilized polycarbonate, with installation hardware and instructions.
G-AM-8-NVS
Easy to install with hardware supplied. Aluminum, with architectural bronze
POLYESTER finish.
G-AM-6-NV
Lighting: Enclosed and Gasketed — Floodlight
Vandal Shield
Top Visor
Replacement Lens
59604249004
Replacement Lens Frame Assembly
59617539001
Lighting
Complete with Lens
1164
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
Areamaster™ 1000 Floodlight Photometric Data
Integrally Ballasted. 1000 W HPS; 1000 W, 1500 W MH
For general or hazardous locations.
Photometric Data †
Typical Footcandle Values †
HPS
134°
131°
77,440
55.3%
40,251
38,396
80,846
57.7%
Horiz. Spread
Vert. Spread
Beam Lumens
Beam Effic.
Max. CP
Avg. Max. CP
Total Lumens
Total Effic.
MH
133°
124°
62,112
56.5%
45,909
38,490
66,008
60.0%
Electrical Specifications
Lamp
Line
Type of
Starting
Type
Voltage
Ballast
Amps
1000 Watt High Pressure Sodium
HPS
120
C.W.A.
6.35
HPS
208
C.W.A.
3.80
HPS
240
C.W.A.
3.20
HPS
277
C.W.A.
2.75
HPS
347
C.W.A.
2.20
HPS
480
C.W.A.
1.80
1000 Watt Metal Halide
MH
120
C.W.A.
8.00
MH
208
C.W.A.
4.60
MH
240
C.W.A.
4.00
MH
277
C.W.A.
3.50
MH
347
C.W.A.
2.50
MH
480
C.W.A.
2.00
1500 Watt Metal Halide
MH
120
C.W.A.
13.50
MH
208
C.W.A.
7.70
Mtg. Ht.
Ft/M
A
Footcandle Values for Iso Footcandle Lines
B
C
D
E
F
1000W HPS Clear, 140,000 Lumens, Cat. No. G-AM861L-MT
60/18.3
8.0
3.0
1.0
0.5
0.20
0.10
50/15.2
11.5
4.6
1.5
0.72
0.27
0.15
40/12.2
17.3
6.8
2.4
1.0
0.45
0.21
30/9.1
31.5
12
4.1
1.9
0.80
0.30
1000W MH Clear, 110,000 Lumens, Cat. No. G-AM861H-MT
60/18.3
6.0
3
1.0
0.5
0.20
0.10
50/15.2
8.2
4.2
1.4
0.8
0.28
0.15
40/12.2
12.6
7.9
2.3
1.2
0.42
0.19
30/9.1
23.0
11.6
4.0
2.1
0.70
0.25
240
C.W.A.
6.70
Total
Watts
9.50
5.50
4.80
4.20
3.30
2.45
1100
1100
1100
1100
1100
1100
9.20
5.30
4.60
4.00
3.20
2.30
1080
1080
1080
1080
1080
1080
14.00
8.00
1610
1610
7.00
1610
MH
277
C.W.A.
5.90
6.00
1610
MH
480
C.W.A.
3.30
3.50
1610
T Numbers and Temperature Ratings of “Classified Duty”
Areamaster 1000
Fixture
Wattage
Fixture Type
T Ratings
Ambient
°C
Temp. ˚°F/°C
T Rating Temperature
Range °F/°C
1000
Class I
Div 2
325
77/25
574-617 / 301-325
1000 V
Ex nR IIC
T3
77/25
277-392 / 136-200
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
Lighting
† Photometric charts available on request.
◊ i.e., ratio of distance to height. Example: @20’/6.1 m mounting height, 1 means 20’/6.1 m; 2 means 40’/12.2 m, etc.
V CSA Certification only.
Lighting: Enclosed and Gasketed — Floodlight
MH
Operating
Amps
1165
PN Series Floodlights – Zone 2, 21 and 22
Metal Halide, Sodium and Mercury
Listed for simultaneous exposure to gas, combustible dusts and flammable gases or vapors.
Zone 2, 21 and 22
II 2 D II 3 GD
ATEX / IECEx
IP66 - IK07/08
Applications
• Powerful, efficient floodlights for large areas such as industrial
complexes and ship loading areas.
• Rated for use in hazardous areas.
Features
• Highly efficient, integrally ballasted floodlight. Has compact,
lightweight, yet rugged die cast aluminum construction.
• Simple installation and maintenance.
• Integral ballast; 230/240 V, 50 Hz.
• One-piece lens cover.
• Heavy duty, high temperature silicone rubber gasket, firmly
seated.
• Socket: E40 (E27 for 70 W HPS version).
• Reflectors: double segment compound parabolic with Alzack®
finish for maximum efficiency.
• Mounting: yoke mount.
Standard Materials
• Ballast housing and lens door: copperfree (4/10 of 1% max.)
aluminum
• Gasket: silicone rubber
• Socket: heavy duty porcelain with heavy gauge brass shell
• Reflector: finished aluminum
• Yoke mount: zinc plated steel
• Bolts: stainless steel
Standard Finishes
• Ballast housing, lens cover, yoke and pole mount: architectural
bronze polyester
• Socket: nickel-plated
• Size M — Certification Type PJn
— Gas: Zone 2
Conforming to ATEX 94/9/CE: CE
3G
ATEX/IEC Protection: Ex nR II
T Rating: T2 to T4
Ambient Temperature: 104 °F to 131 °F/40 °C to 55 °C
— Dust: Zone 22
II 3 D
Conforming to ATEX 94/9/CE: CE
ATEX/IEC Protection: Ex tD A22
Surface Temperature: T243 °F/T117 °C to 442 °F/T228 °C
— Gas, Zone 2 and Dust, Zone 22
Ambient Temperature: 104 °F to 131 °F / 40 °C to 55 °C
ATEX Certificate: LCIE 08 ATEX 6035X
IEC Certificate: IECEx LCI 04.0015
Other Certifications: GOST
Impact Resistance (shock): IK07
— Dust: Zone 21
I2D
Conforming to ATEX 94/9/CE: CE
ATEX/IEC Protection: Ex tD A21
Surface Temperature: T149 °F to T277 °F/T65 °C to
T136 °C
Ambient Temperature: -4 °F to 104 °F/-20 °C to 40 °C
ATEX Certificate: LCIE 02 ATEX 6246X
Impact Resistance (shock): IK07 with glass diffuser, IK08
with polycarbonate diffuser
— CE Declaration of Conformity: 50251
— Index of Protection (solid and liquid): IP66
Lighting
Lighting: Enclosed and Gasketed — Floodlight
Certifications and Compliances
• Size G — Certification Type PJn
— Gas: Zone 2
Conforming to ATEX 94/9/CE: CE
3G
ATEX/IEC Protection: Ex nR II
T Rating: T3
— Dust: Zone 22
Conforming to ATEX 94/9/CE: CE
II 3 D
ATEX/IEC Protection: Ex tD A22
Surface Temperature: T369 °F to T378 °F/T187 °C
to T192 °C
— Gas, Zone 2 and Dust, Zone 22
Ambient Temperature: 104 °F to 131 °F/40 °C to 55 °C
CE Declaration of Conformity: 50215
ATEX Certificate: LCIE 08 ATEX 6035X
IEC Certificate: IECEx LCI 04.0015
Other Certifications: GOST
Impact Resistance (shock): IK07
— Dust: Zone 21
Conforming to ATEX 94/9/CE: CE 008
II 2 D
ATEX/IEC Protection: Ex tD A21
Surface Temperature: T250°F to T360°F / T121°C
to T182°C
Ambient Temperature: -4°F to 104°F / -20°C to 40°C
CE Declaration of Conformity: 50274
ATEX Certificate: LCIE 02 ATEX 6246X
Impact Resistance (shock): IK07 with glass diffuser, IK08
with polycarbonate diffuser
— Index of Protection (solid and liquid): IP66
• Ex Standards: EN/IEC 60079-0, 60079-15, 61241-0, 61241-1
• Product Standards: EN/IEC 60598-1
• EMC Standards: EN/IEC 55015, 61547
• Other Standards: EN/IEC 60529 (IP)
1166
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
PN Series Floodlights – Zone 2, 21 and 22
Metal Halide, Sodium and Mercury
Listed for simultaneous exposure to gas, combustible dusts and flammable gases or vapors.
Zone 2, 21 and 22
II 2 D II 3 GD
ATEX / IECEx
IP66 - IK07/08
Order using catalog numbering guide below or select catalog number from tables on following pages.
Catalog Numbering Guide For PN Series Luminaires
PN
P
Series:
PN - PN Series
Zone 2, 21 & 22
ATEX / IEC Certified
Body Size:
P - Small
M - Medium
L - Large
1
H
Mounting:
1 - Yoke
5 - Pole Slip-fit
70
Wattage:
70 - 70 W
15 - 150 W
25 - 250 W
40 - 400 W ①
99 - 1000 W ①
Lamp Type:
H - Metal Halide
L - Sodium
M - Mercury
A
G
MT
Diffuser:
G - Glass
P - Polycarbonate ②
Entry Size:
A - M20
F
Options:
S - Stainless Steel
Housing
Options:
XA - 220 Vac 50 Hz
(Magnetic Ballast)
XJ - 230/240 Vac 50 Hz
(Magnetic Ballast)
Lighting: Enclosed and Gasketed — Floodlight
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
Lighting
① 400 W Zones 21-22 and 1000 W Zones 2-22 only with large body (suffix -G).
② Zone 2-22 doesn’t exist with polycarbonate diffuser.
1167
PN Series Floodlight T Ratings – Zone 2, 21 and 22
Metal Halide, Sodium and Mercury
Listed for simultaneous exposure to gas, combustible dusts and flammable gases or vapors.
Zone 2, 21 and 22
II 2 D II 3 GD
ATEX / IECEx
IP66 - IK07/08
Zone 21 (Dust)
Dust Surface Temperatures for Ta = 104 °F/40 °C
Operating Position
Body Size: M
Body Size: L
Lamp and Power
70 W Sodium
150 W Sodium
250 W Sodium
250 W Metal Halide
250 W Mercury
400 W Sodium
1000 W Sodium
1000 W Metal Halide
Glass Diffuser
167 °F/75 °C
213.8 °F/101 °C
260.6 °F/127 °C
253.4 °F/123 °C
276.8 °F/136 °C
25.8 °F/126 °C
350.6 °F/177 °C
359.6 °F/182 °C
Polycarbonate Diffuser
149 °F/65 °C
195.8 °F/91 °C
242.6 °F/117 °C
235.4 °F/113 °C
267.8 °F/131 °C
249.8 °F/121 °C
–
–
Time Before Opening
in Inches/Millimeters
1.97/50
0.99/25
0.59/15
0.59/15
0.59/15
1.18/30
1.18/30
1.18/30
Lamp and Power
70 W Sodium
150 W Sodium
150 W Metal Halide
250 W Sodium
250 W Metal Halide
250 W Mercury
400 W Sodium
400 W Metal Halide
400 W Mercury
1000 W Sodium
1000 W Metal Halide
T Rating for Ta = 104 °F/40 °C
T4
T4
T4
T3
T3
T3
T3
T2
T2
T3
T3
T Rating for Ta = 122 °F/50 °C
T4
T4
T4
T3
T3
T3
T3 (Cable T ° = 188.6 °F/87 °C)
T2 (Cable T ° = 183.2 °F/84 °C)
T2 (Cable T ° = 183.2 °F/84 °C)
T3
T3
T Rating for Ta = 131 °F/55 °C
T4
T4
T4
T3 (Cable T ° = 179.6 °F/82 °C)
T3
T3 (Cable T ° = 177.8 °F/81 °C)
T2 (Cable T ° = 197.6 °F/92 °C)
T2 (Cable T ° = 192.2 °F/89 °C)
T2 (Cable T ° = 192.2 °F/89 °C)
–
–
Lamp and Power
70 W Sodium
150 W Sodium
150 W Lodure
250 W Sodium
250 W Lodure
250 W Mercury
400 W Sodium
400 W Lodure
400 W Mercury
T Rating for Ta = 104 °F/40 °C
242.6 °F/117 °C
2.66 °F/130 °C
262.4 °F/128 °C
320 °F/160 °C
47 °F/175 °C
357.8 °F/181 °C
388.4 °F/198 °C
442.4 °F/228 °C
440.6 °F/227 °C
368.6 °F/187 °C
(for Ta = 122 °F/50 °C)
377.6 °F/192 °C
(for Ta = 122 °F/50 °C)
T Rating for Ta = 122 °F/50 °C
–
–
–
–
–
–
T3 (Cable T ° = 188.6 °F/87 °C)
T2 (Cable T ° = 183.2 °F/84 °C)
T2 (Cable T ° = 183.2 °F/84 °C)
T Rating for Ta = 131 °F/55 °C
–
–
–
T3 (Cable T ° = 179.6 °F/82 °C)
–
T3 (Cable T ° = 177.8 °F/81 °C)
T2 (Cable T ° = 197.6 °F/92 °C)
T2 (Cable T ° = 192.2 °F/89 °C)
T2 (Cable T ° = 192.2 °F/89 °C)
Cable T ° = 194 °F/90 °C
–
Cable T ° = 194 °F/90 °C
–
Zone 2 (Gas)
Body Size: M
Lighting: Enclosed and Gasketed — Floodlight
Body Size: L
Zone 22 (Dust)
Body Size: M
1000 W Sodium
Body Size: L
Lighting
1000 W Lodure
1168
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
PN Series Floodlights – Zone 2, 21 and 22
Metal Halide, Sodium and Mercury
Listed for simultaneous exposure to combustible dusts and flammable gases or vapors.
Zone 2, 21 and 22
II 2 D II 3 GD
ATEX / IECEx
IP66 - IK07/08
Type
Weight (lbs/kg)
Volume (in3/dm3)
Permissible lamps
(not supplied)
Body Size
Catalog Number
Standard with Lamp Glass Sealed on Frame
70 W HP Sodium
26.7/12.1
3814/62.5
Ovoid/Tubular
Medium
PNM1L70AGXJ
150 W HP Sodium
28.4/12.9
3814/62.5
Ovoid/Tubular
Medium
PNM1L15AGXJ
250 W HP Sodium
31.5/14.3
3814/62.5
Ovoid/Tubular
Medium
PNM1L25AGXJ
400 W HP Sodium
35.3/16.0
3814/62.5
Ovoid/Tubular
Medium
PNM1L40AGXJ
400 W HP Sodium
–
–
Ovoid/Tubular
Large
PNL1L40AGXJ
150 W Metal Halide
28.4/12.9
3814/62.5
Ovoid/Tubular
Medium
PNM1H15AGXJ
250 W Metal Halide
31.5/14.3
3814/62.5
Ovoid/Tubular
Medium
PNM1H25AGXJ
400 W Metal Halide
35.3/16.0
3814/62.5
Tubular
Medium
PNM1H40AGXJ
400 W Metal Halide
–
–
Ovoid/Tubular
Large
PNL1H40AGXJ
250 W Mercury Vapor
28.4/12.9
3814/62.5
Ovoid
Medium
PNM1M25AGXJ
400 W Mercury Vapor
30.4/13.8
3814/62.5
Ovoid/Tubular
Medium
PNM1M40AGXJ
With External Polycarbonate Weatherproof Protection
70 W HP Sodium
29.1/13.2
3814/62.5
Ovoid/Tubular
Medium
PNM1L70APXJ
150 W HP Sodium
30.9/14.0
3814/62.5
Ovoid/Tubular
Medium
PNM1L15APXJ
250 W HP Sodium
34.0/15.4
3814/62.5
Ovoid/Tubular
Medium
PNM1L25APXJ
400 W HP Sodium
–
–
Ovoid/Tubular
Large
PNL1L40APXJ
150 W Metal Halide
30.9/14.0
3814/62.5
Ovoid/Tubular
Medium
PNM1H15APXJ
250 W Metal Halide
34.0/15.4
3814/62.5
Ovoid/Tubular
Medium
PNM1H25APXJ
–
–
Ovoid/Tubular
Large
PNL1H40APXJ
30.9/14.0
3814/62.5
Ovoid
Medium
PNM1M25APXJ
400 W Metal Halide
250 W Mercury Vapor
Description
Catalog Number
Fall Prevention Kit
(3.94"/1.2 m stainless steel chain) for M20 cable entry
FESCM20
Slipfitter Adapter — fits medium body
GSF20
Slipfitter Adapter — fits large body
GAM8SF
Lighting: Enclosed and Gasketed — Floodlight
Accessories
Lighting
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
1169
PN Series Floodlight Dimensions and Photometric Data – Zone 2, 21 and 22
Metal Halide, Sodium and Mercury
Listed for simultaneous exposure to combustible dusts and flammable gases or vapors.
Dimensions
Size M
Size L
7.76”/197 mm
7.36”/
197 mm
22.17”/563.0 mm
5.55”/
141.0 mm
3.50”/
89.0 mm
2.78”/
70.5 mm
2.01”/
51.0 mm
(3) Mounting Holes
0.55”/14.0 mm
16.14”/410.0 mm
2.01”/
51.0 mm
5.55”/
141.0 mm
(3) Mounting Holes
0.54”/13.8 mm
3.50”/
89.0 mm
5.12”/
130.0 mm
5.12”/
130.0 mm
2.17”/
55.0 mm
3.50”/
89 mm
11.22”/
285.0 mm
13.50”/
343.0 mm
19.68”/500.0 mm
22.17”/563.0 mm
16.92”/460.0 mm
3.62”/
92.0 mm
3.62”/
92.0 mm
Photometric Data
Lamps: 70 W High Pressure Sodium
Polar curves for a 1000 lm flux, according to NF C 71-120
Luminaire symbol according to NF C 71-121
Candelas
(0-180)
(90-270)
0
487
487
5
439
461
10
416
387
15
372
324
20
208
290
25
129
294
30
116
319
35
111
318
40
101
289
45
86
193
50
70
150
55
84
141
60
62
132
65
22
88
70
9
15
Total Luminaire Efficiency = 74.6%
Degrees
Longitudinal
Transverse
Lighting
Lighting: Enclosed and Gasketed — Floodlight
Degrees
1170
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
Corroflood™ 250/400 Stainless Steel Floodlights
Integral Ballast. 250 W, 400 W HPS or PSMH. Mogul Base
For Marine; Class I, Division 2 Hazardous Locations; Class I, Zone 2; and Corrosive Environments.
Class I, Division 2, Groups A, B, C, D
NEMA 4X
Suitable for Marine, Outdoor Salt Water
Location
Applications
• Powerful, efficient weatherproof lighting for medium and large
areas such as chemical plants, refineries, shipboard and marine
industrial process areas where severely corrosive agents are
present.
Features
• Compact in size, rugged and dependable.
• Easy to install and service.
• A wide range of ballasts and voltages are available for both
domestic and export applications.
• Integral ballast.
• Completely assembled fixture saves installation time and cost.
• Easily removable ballast tray.
• Hinged door.
• Seamless welded construction.
• Can be mounted in any position ranging from lens down to
horizontal, lens up.
• Stainless steel latches to allow relamping without tools.
Standard Materials
• Fixture body and trunnion arm: 316 stainless steel
• 16 gauge 316 stainless steel
• Lens: thermal-shock-resistant and tempered impact-resistant
glass
• Gasket: heavy-duty, high-temperature silicone rubber, firmly
seated
• Socket: heavy-duty, mogul base porcelain with heavy gauge
brass, nickel-plated, double lamp-grip screw shell and springloaded center contact
• Reflector: compound parabolic, double segment, finished
aluminum for optimum efficiency
Certifications and Compliances
• UL Standard: UL 1598, UL 1598A, UL 844
• UL Listed: E10794
Line Voltage
T Rating
For Class I, Division 2
Classified Duty and Marine
Yoke Mount Catalog Number ➋
High Pressure Sodium
400 W HPS
120/208/240/277
350
SSF771L-MT-I/2
400 W HPS
120/277/347
350
400 W HPS
250 W HPS
480
120/208/240/277
350
350
SSF771L-TT-I/2 V
SSF771L-48-I/2
SSF671L-MT-I/2
250 W HPS
120/277/347
350
480
350
SSF671L-TT-I/2 V
SSF671L-48-I/2
250 W HPS
Pulse Start Metal Halide
400 W PSMH
120/208/240/277
350
SSF771P-MT-I/2
400 W PSMH
120/277/347
350
400 W PSMH
250 W PSMH
480
120/208/240/277
350
350
SSF771P-TT-I/2 V
SSF771P-48-I/2
SSF671P-MT-I/2
250 W PSMH
120/277/347
350
250 W PSMH
480
350
SSF671P-TT-I/2 V
SSF671P-48-I/2
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
1171
Lighting
Floodlights have 3/4” NPT tapped hub for power entry.
➊ Quartz emergency option NOT available for Class I, Division 2 fixtures. Contact your local sales representative for emergency quartz for non-classified areas.
V CSA Certification only.
Lighting: Enclosed and Gasketed — Floodlight
Lamp Type
Corroflood™ 250/400 Stainless Steel Floodlights
Integral Ballast. 250 W, 400 W HPS or PSMH. Mogul Base
For Marine; Class I, Division 2 Hazardous Locations; Class I, Zone 2; and Corrosive Environments.
Mounting Fittings and Accessories
Description
Catalog Number
Crossarm Mounting Bracket — Has 180° horizontal adjustment—degreemarked. Facilitates mounting floodlight to crossarm or other flat surface, or to
G-AM-8-WB.
Includes floodlight yoke bolts. Malleable iron, zinc plated, chromate sealed,
architectural bronze polyester finish.
Pipe or Wall Mount Bracket — Used with G-AM-8-CA. Clamps to 1” to
2-1/2” pipe, vertical or horizontal, or mounts on flat surfaces. Includes U-bolt
and crossarm bracket bolts. Malleable iron, zinc plated, chromate sealed, with
architectural bronze POLYESTER finish.
Poletop Slip-Fitter — 1-1/2” or 2” pipe size poletop tenons. Includes floodlight
yoke bolt, 3 locking bolts, and cord grip. Body is malleable iron—zinc plated,
chromate sealed, with cast aluminum cap. Assembly has architectural bronze
polyester finish.
G-AM-8-CA
G-AM-8-WB
G-SF20
Poletop Slip-Fitter — Slip-Fits 2” or 2-1/2” poletop tenons. Includes floodlight
yoke bolts, 3 locking bolts and cord grip. Malleable iron, zinc plated, chromate
sealed, with architectural bronze polyester finish.
G-AM-8-SF
Dimensions
7.00”/
177.8 mm
Lighting: Enclosed and Gasketed — Floodlight
23.00”/584.2 mm
18.50”/469.9 mm
17.25”/438.15 mm
0.38”/9.1 mm
Dia. (2) Outer Holes
0.56”/14.3 mm
Dia. Center Hole
18.50”/469.9 mm
1.75”/
44.45 mm
3.50”/
88.9 mm
Trunnion Mount
3.50”/88.9 mm
6.00”/152.4 mm
4.50”/
114.3 mm
Lighting
4.00”/101.6 mm
Crossarm Mounting Bracket
1172
Pipe or Wall Mount Bracket
Poletop Slip-Fitter
Poletop Slip-Fitter
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
Corroflood™ 250/400 Stainless Steel Floodlight Photometric Data
Integral Ballast. 250 W, 400 W HPS or PSMH. Mogul Base
For Marine; Class I, Division 2 Hazardous Locations; Class I, Zone 2; and Corrosive Environments.
Electrical Specifications — All ballasts are CWA type
Typical Footcandle Values †
Line Voltage
Starting Amps
400 W High Pressure Sodium
120
3.30
208
1.80
240
1.60
277
1.40
347
1.00
480
0.80
400 W Pulse Start Metal Halide
120
3.50
208
2.00
240
1.25
277
1.50
347
1.10
480
0.90
250 W High Pressure Sodium
120
2.00
208
1.20
240
1.00
277
0.85
347
0.60
480
0.40
250 W Pulse Start Metal Halide
120
1.90
208
1.10
240
0.96
60/18.3
50/15.2
40/12.2
30/9.1
20/6.1
60/18.3
50/15.2
40/12.2
30/9.1
20/6.1
Total Watts
3.80
2.20
1.90
1.70
1.32
1.00
465
465
465
465
464
465
4.00
2.30
2.00
1.75
1.35
1.00
454
454
454
454
452
454
2.50
1.50
1.30
1.10
0.93
0.65
295
295
295
295
295
295
2.50
1.45
1.25
288
288
288
277
0.85
1.10
288
347
0.62
0.90
291
480
0.45
0.60
285
Footcandles for Iso-Footcandle Lines
A
B
400 W HPS
3.27
2.74
4.74
4.00
7.65
6.28
13.10
10.92
28.22
25.55
400 W PSMH
2.60
1.86
3.72
2.60
6.14
4.05
10.96
8.74
19.33
16.35
C
D
E
F
1.82
2.90
4.38
7.83
17.37
0.92
1.37
2.27
3.47
7.28
0.37
0.52
0.82
1.45
3.46
0.18
0.27
0.43
0.77
1.82
1.12
1.66
2.60
4.46
10.41
0.65
0.85
1.49
2.42
5.94
0.37
0.54
0.84
1.49
3.53
0.19
0.28
0.40
0.76
1.67
A
B
250 W HPS
1.96
1.64
2.84
2.40
4.58
3.76
7.85
6.54
16.90
15.30
250 W PSMH
1.90
1.36
2.72
1.90
4.48
2.96
8.00
6.40
14.40
11.97
C
D
E
F
1.09
1.74
2.62
4.69
10.40
0.55
0.82
1.36
2.08
4.36
0.22
0.31
0.49
0.87
2.07
0.11
0.16
0.26
0.46
1.09
0.82
1.22
1.90
3.26
7.61
0.48
0.63
1.09
1.76
4.35
0.27
0.39
0.61
1.09
2.58
0.14
0.20
0.30
0.55
1.22
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
Lighting
† Photometric charts available on request.
◊ i.e., ratio of distance to height. Example: @ 20’/6.1 m mounting height, 1 means 20’/6.1 m; 2 means 40’/12.2 m, etc.
Lighting: Enclosed and Gasketed — Floodlight
Mtg. Ht.
Ft/M
Operating Amps
1173
Wallmaster I/2 for Hazardous and Wet Locations — Class I, Division 2/Zone 2 V
cCSAus Certification Only. Enclosed and Gasketed. Integrally Ballasted. 70 W, 100 W, 150 W HPS
Class I, Division 2, Groups A, B, C, D
Class I, Zone 2, Groups IIA, IIB, IIC
Applications
• Wall mounted luminaire suitable for outdoor applications.
• Areas where flammable gases are present under conditions
defines by NEC Class I, Division 2.
Features
• Attractive yet rugged design.
• Side hinged door allows unobstructed access to lamp and
wiring components.
• Built in stop limits door opening to 90° and protects the lens
from breakage.
• Latch mechanism: unique heavy-duty stainless steel latch
secures the cover assembly while allowing the luminaire to be
relamped without the use of tools.
• Prismatic tempered glass lens is thermal-shock- and impactresistant giving a soft diffused light.
• Installation is fast and easy.
• Luminaire is furnished with two plugged 1/2” conduit entries. A
1/2” knockout allows rear entry.
• Mogul base socket is heavy-duty porcelain with heavy gauge
brass nickel plated double lamp grip screw shell and spring
loaded center contacts.
• Aluminum reflector is designed for maximum efficiency.
• Standard finish is architectural
bronze tone baked epoxy.
Certifications and Compliances
•
•
•
•
UL Standard: UL 1598, UL 844
CSAus Certified: 025428
CSA Standard: C22.2 No. 250, C22.2 No. 137
CSA Certified: 025428
Order using catalog numbering guide below.
Catalog Numbering Guide For Wallmaster I/2 Luminaires
Lighting: Enclosed and Gasketed — Floodlight
Series:
GWM - Wallmaster
Lighting
GWN
V CSA Certification only.
70
L
Lamp Type:
L - High Pressure Sodium
F - Fluorescent
Wattage:
70 - 70 W HPS
10 - 100 W HPS
15 - 150 W HPS
36 - Two 18 W PL-T
52 - Two 26 W PL-T
64 - Two 32 W PL-T
1174
MT
H
R
Ratings:
H - Hazardous Location
Voltage:
48 - 480
MT - 120/208/240/277
BU - 120-277, 50/60 Hz (Fluorescent
Only)
TT - 120/277/347
Options:
E – Quartz Auxiliary Light (NonHazardous HID only)
G – Wire Guard
Q – Hazardous Photocontrol 120
to 277 Vac (Class I, Div. 2)
R – HRE (Hot Restrike for HID
only)
S – PE (Safety Starter for HID
only)
T – Tamper proof Latch
V – Polycarbonate Vandal Shield
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
Wallmaster I/2 for Hazardous and Wet Locations — Class I, Division 2/Zone 2 V
cCSAus Certification Only. Enclosed and Gasketed. Integrally Ballasted. 70 W, 100 W, 150 W HPS
Class I, Division 2, Groups A, B, C, D
Class I, Zone 2, Groups IIA, IIB, IIC
“T” Numbers for Wallmaster I/2 Fixtures
Lamp
Watts
Lamp
Type
Supply
Wire °F/°C
Maximum Ambient
Temperature °F/°C
Class I, Division 2
Class I, Zone 2
70
HPS
257/125
104/40
T2D
100
HPS
257/125
77/25
T2C
150
HPS
257/125
77/25
T2A
36
Fluorescent
257/125
104/40
131/55
T3
52
Fluorescent
257/125
104/40
131/55
T3
64
Fluorescent
257/125
104/40
131/55
T3
“T” Numbers Represent the Maximum Lamp Temperature for Class I, Division 2 Locations
“T”
Number
T1
350
325
T2
T2A
T2B
T2C
T2D
T3
T3A
T3B
T3C
T4
T4A
T5
T6
Temp.
Range
(˚ºF)
664842
619662
574617
538572
502536
448500
421446
394419
358392
331356
322329
277320
250275
214248
187212
185
Temp.
Range
(°C)
351450
326350
301325
281300
261280
231260
216230
201215
181200
166180
161165
136160
121135
101120
86100
85
Accessories
Description
Catalog Number
GWMWG
Vandal Shield - UV stabilized polycarbonate. Can be used with guard.
GWMLS
Clear Replacement Lens
GWML
Lighting: Enclosed and Gasketed — Floodlight
Guard - Stainless steel plated
Dimensions
5.44”/
138.1 mm
14.00”/355.6 mm
12.13”/
308.0 mm
Lighting
V CSA Certification only.
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
1175
TVA Obstruction, Approach and Boundary Luminaires V
Lighting: Enclosed and Gasketed — Visual Signal
Lighting
CSA Certification Only
For use with Threaded Rigid Metal Conduit and IMC.
Class I, Division 2 versions available
Applications
• Transport Canada approved TVA490 series low intensity
obstruction, approach or boundary light.
• TVA490 series obstruction lights are suitable for use on
communication towers or other tall structures and buildings.
Features
• TVA obstruction lights are available with one or two lamps.
• Models are equipped with rainports in the globe holder which
keeps the wiring chamber dry.
• TVA obstruction lights are rugged cast aluminum construction.
• Two lamp fixtures are furnished with pre-wired sockets.
• Utilizes Type A-21 116 W clear traffic signal lamp.
• A corrosion resistant finish protects TVA fixtures. TVA490
obstruction lights are approved for use by Transport Canada.
• Engineered for easy and safe maintenance, TVA490 fixtures are
serviced without tools:
(1) The globe holder is secured with a captive thumb screw
(2) a one-eighth turn twist removes the globe and lobe holder
(3) the assembly is hung from a safety chain freeing both hands
• Fresnel glass lenses and three lamp holder positions permit
use of TVA490 fixtures on structures below 50 feet/15.2 meters,
from 50 to 100 feet / 15.2 to 30.5 meters, and over
100 feet/30.5 meters.
• A plugged 1" side hub and a 1-1/4" bottom hub provide
conduit entry.
• Transfer and failure alarm relays for both one and two
lamp fixtures.
• Pilot light assembly contains a red pilot light to indicate lamp
failure.
Standard Materials
• TVA bodies: copperfree (4/10 of 1% max.) aluminum
• Lamp holders: porcelain
• Transfer and failure alarm, pilot light assembly: ferrous alloy
enclosure
• Supply wire requirement: 90 ºC
TVA 1490
TVA 2490
Standard Finish
• TVA490: international orange epoxy clad finish
• Transfer failure alarm, pilot light assembly: triple coat – (1) zinc
electroplate, (2) chromate and (3) aluminum polymer enamel
Certifications and Compliances
• CSA Standard: C22.2 No. 250
• CSA Certified: 009349
V CSA Certification only.
1176
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
TVA Obstruction, Approach and Boundary Luminaires V
CSA Certification Only
Lighting
For use with Threaded Rigid Metal Conduit and IMC.
Class I, Division 2 versions available
Hub Size (Inches)
Side
Bottom
Catalog Number
TVA490 Obstruction, Approach and Boundary Lights
Type A-21 Clear Traffic Signal Light 116 W
One Lamp Fixtures
Obstruction with Red Globe
—
1
TVA1490
Approach with Yellow Globe
—
1
TVA1490Y
Boundary with Clear Globe
—
1
TVA1490C
One Lamp Haz. Loc. Fixtures
Obstruction with Red Globe
—
1
TVA1490H
Approach with Yellow Globe
—
1
TVA1490YH
Boundary with Clear Globe
—
1
TVA1490CH
Two Lamp Fixtures
Obstruction with Red Globe
1
1-1/4 ①
TVA2490
Approach with Yellow Globe
1
1-1/4 ①
TVA2490Y
Boundary with Clear Globe
1
1-1/4 ①
TVA2490C
1
1-1/4 ①
TVA2490H
Two Lamp Haz. Loc. Fixtures
Obstruction with Red Globe
Approach with Yellow Globe
1
1-1/4 ①
TVA2490YH
Boundary with Clear Globe
1
1-1/4 ①
TVA2490CH
Single Lamp
—
1
TVA1400
Two Lamp
1
1-1/4
TVA2400
TVA490 Replacement Parts
Mounting Fittings
With Globe Holder and Lamp Socket
Globes
Fresnel
Red
V-990R
Aviation yellow
V-990Y
Clear
V-990C
Lamp Socket
Porcelain — Medium Base
V-1025
Globe Gasket
Neoprene
V-2055G
Wiring Chamber Cover
Cover assembly for two lamp fixture wiring
chamber. With gasket and screws
V-2010
① To order with 1/4" to 1" reducer in the bottom hub add suffix -RB100.
V CSA Certification only.
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
1177
Lighting: Enclosed and Gasketed — Visual Signal
Description
TVA Obstruction, Approach and Boundary Luminaire Accessories V
Lighting: Enclosed and Gasketed — Visual Signal
Lighting
CSA Certification Only
For use with Threaded Rigid Metal Conduit and IMC.
Class I, Division 2 versions available
Description
Hub Size
(Inches)
Catalog
Number
Lamp Failure Alarm
In the event of both lamps failing in the obstruction light an
alarm circuit is triggered.
Weather-proof enclosure is furnished with feed-thru hubs.
120 Vac, 50/60 Hz
Relay drops out at 0.6 amps.
1
FDC-32R2
In the event of a lamp failure, power is transferred to the
standby lamp and an alarm circuit is activated.
Weather-proof enclosure is furnished with feed-thru hubs.
120 Vac, 50/60 Hz
Relay drops out at 0.6 amps.
1
FDC-32R1
Connected to failure alarm to indicate lamp failure.
Red pilot light.
6S6 candelabra base lampholder.
Dead end enclosure.
1
FD-3J1
Transfer Relay and Lamp Failure Alarm
Pilot Light Assembly
Photocell
(Non-Hazardous)
Comes installed in FDO type enclosure, ready for installation.
120 V Only.
FS601
(Class I, Division 2)
As above, c/w Encapsulated Photocell for Hazardous Area
installation. 120 V Only.
FS601D2
Comes installed in FDO type enclosure, ready for installation.
2500 W Rated, 200 A Max. In-Rush FAA approved 30 FPM
Flash Rate.
TVA-FL
Flasher Assembly
V CSA Certification only.
1178
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
TVA Obstruction, Approach and Boundary Luminaire Dimensions V
CSA Certification Only
Lighting
For use with Threaded Rigid Metal Conduit and IMC.
Dimensions (Inches/Millimeters)
A
B
Lighting: Enclosed and Gasketed — Visual Signal
Description
Catalog Number
One Lamp
Single
10.00/254.0
4.25/107.95
TVA1490
Twin
10.75/273.05
13.75/349.25
TVA2490
Two Lamp
V CSA Certification only.
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
1179
Stylmaster™ Strobe Luminaires
Lighting: Enclosed and Gasketed — Visual Signal
Lighting
Enclosed and Gasketed
NEC: Pendant Mount
Class I, Division 2, Groups A, B, C, D
Class II, Division 1 and 2, Groups E, F, G
Class III
NEMA 3R, 4
Marine Outside Type (Saltwater)
NEC: Ceiling and Wall Bracket Mount
Class I, Division 2, Groups A, B, C, D
NEMA 3R, 4
CEC: V
Class I, Division 2, Groups A, B, C, D
Class II, Division 1 and 2, Groups E, F, G
Class III
CSA Enclosure 3
Applications
• Enclosed and gasketed fixtures suitable for use in:
— Marine and wet locations
— Industrial processing
— Chemical processing
— Areas where flammable gases and vapors are present under
conditions defined by NEC Class I, Division 2; Class II,
Division 1 and 2; and Class III
• For use in areas where audible signals cannot be heard.
• Used to warn of unsafe conditions and other communication
needs.
• Fixtures are also suited for use in non-hazardous areas where
there are:
— Severe weather conditions
— Excessive moisture, dirt, dust
— Corrosive atmospheres
— High ambient temperatures are encountered
• Typical applications include:
— Pulp and paper mills
— Processing plants
— Chemical plants
— Oil refineries
— Foundries
— Manufacturing plants
— Storage areas
— Marine applications
Features
• Modern styling, with clean-line mounting hood and prismatic
glass globe, plus optional guard.
• Globe seats firmly against silicone gasket in mounting
hood to keep out dirt and moisture. Full threads eliminate “cross
threading.”
• Optional guard protects glass from damage and has
exclusive snap-on attachment feature for quick installation
and fast servicing.
• Fixtures operate safely in high ambient temperatures.
• Strobe: 65 flashes per minute. 800,000 peak candlepower.
• Fixtures are complete with lamp.
• Lens available in five colors: red, amber, blue, green and
clear (factory installed).
• Heat- and impact-resistant globes have smooth
dust-resistant exterior.
• Fixture is suitable for mounting globe up or globe down utilizing
pendant, ceiling or wall bracket type mounts.
• Minimum operating temperature is -13 °F/-25 °C.
Fixtures are suitable for mounting in any position – including globe up or
globe down – utilizing pendant, ceiling or wall bracket type mounts.
Standard Materials
• Mounting hoods: copperfree (4/10 of 1% max.) aluminum
• Guards: pressure cast copperfree (4/10 of 1% max.) aluminum
• Globes: prismatic glass
Standard Finish
• Mounting hoods and guards: powder coat epoxy
Certifications and Compliances
•
•
•
•
UL Standard: UL 1203, UL 1638
UL Listed: E207738
CSA Standard: C22.2 No. 25
cUL Listed: E207738
V CSA Certification only.
1180
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
Stylmaster™ Strobe Luminaires
Enclosed and Gasketed
NEC: Ceiling and Wall Bracket Mount
Class I, Division 2, Groups A, B, C, D
NEMA 3R, 4
Lighting
NEC: Pendant Mount
Class I, Division 2, Groups A, B, C, D
Class II, Division 1 and 2, Groups E, F, G
Class III
NEMA 3R, 4
Marine Outside Type (Saltwater)
CEC: V
Class I, Division 2, Groups A, B, C, D
Class II, Division 1 and 2, Groups E, F, G
Class III
CSA Enclosure 3
Lighting: Enclosed and Gasketed — Visual Signal
Order using catalog numbering guide below or select catalog number from tables on following pages.
Catalog Numbering Guide For VP Stylmaster Strobe Luminaires
VP
A
S
Series:
VP - Stylmaster
75
120AC
Lamp Type:
S - Strobe
CL
G
Options:
G - Guard
Voltage Current:
120AC - 120 Vac
240AC - 240 Vac
1248DC - 12-48 Vdc
24PDC - 24 Vdc ①
250DC - 250 Vdc
Mounting Hood:
A - Pendant
X - Ceiling
WB - Wall Bracket
Hub Size:
75 - 3/4”
Globe:
CL - Clear
AM - Amber
BL - Blue
GR - Green
RE - Red
Technical Data: Thermal Suitability of Stylmaster Strobe
Operating Temperatures
Ambient
Temp. (°F/°C)
104/40
131/55
149/65
Class I, Division 2 Groups A,B,C,D
Pendant, Ceiling and Wall Bracket
T2A
T2
T1
Class II, Division 1& 2 and Class III
Pendant Mount
T4A
T4A
T4
Operating Temperatures Represent the Maximum Internal Temperature for Class I, Division 2 Locations and
Maximum Surface Temperature Under Dust Blanket for Class II, Division 1 Locations.
“T”
Number
T1
350
325
T2
T2A
T2B
T2C
T2D
T3
T3A
T3B
T3C
T4
T4A
T5
T6
Temp.
Range
(˚ºF)
664842
619662
574617
538572
502536
448500
421446
394419
358392
331356
322329
277320
250275
214248
187212
185
Temp
Range
(°C)
351-
450
326-
350
301-
325
281-
300
261-
280
231-
260
216-
230
201-
215
181-
200
166-
180
161165
136-
160
121-
135
101-
86-100
120
85
NOTE: The maximum operating temperature of the fixture must not exceed the ignition temperature of the gas, vapor or dust to be encountered per the National
Electrical Code and the Canadian Electrical Code.
① Diode Polarized (current limiter supplied as standard).
V CSA Certification only.
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
1181
Stylmaster™ Strobe Luminaires
Lighting: Enclosed and Gasketed — Visual Signal
Lighting
Enclosed and Gasketed
NEC: Pendant Mount
Class I, Division 2, Groups A, B, C, D
Class II, Division 1 and 2, Groups E, F, G
Class III
NEMA 3R, 4
Marine Outside Type (Saltwater)
NEC: Ceiling and Wall Bracket Mount
Class I, Division 2, Groups A, B, C, D
NEMA 3R, 4
CEC: V
Class I, Division 2, Groups A, B, C, D
Class II, Division 1 and 2, Groups E, F, G
Class III
CSA Enclosure 3
Volts
Wt. (lbs/kg)
Catalog Number ①
Pendant — Rigid Conduit One Hub 3/4” NPT
VPAS75120ACCL
120 Vac
VPAS75240ACCL
240 Vac
250 Vdc
4.5/2.0
VPAS75250DCCL
12-48 Vdc
VPAS751248DCCL
24 Vdc
VPAS7524PDCCL ②
120 Vac
VPXS75120ACCL
240 Vac
VPXS75240ACCL
Ceiling — Rigid Conduit Four Hubs 3/4” NPT Three Close-Up Plugs
250 Vdc
5.3/2.4
VPXS75250DCCL
12-48 Vdc
VPXS751248DCCL
24 Vdc
VPXS7524PDCCL ②
120 Vac
VPWBS75120ACCL
Wall Bracket — Rigid Conduit Four Hubs 3/4” NPT Three Close-Up Plugs
VPWBS75240ACCL
240 Vac
250 Vdc
6.4/2.9
VPWBS75250DCCL
12-48 Vdc
VPWBS751248DCCL
24 Vdc
VPWBS7524DCCL ②
Optional Aluminum Guard
1.0/0.5
VPGU-1
① Catalog numbers shown are supplied with clear lens. To order colored lens, replace the last digits of catalog number CL with AM for amber, BL for blue,
GR for green or RE for red.
② Diode Polarized (current limiter supplied as standard).
V CSA Certification only.
1182
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
Stylmaster™ Strobe Luminaire Replacement Parts and Dimensions
Enclosed and Gasketed
Lighting
Replacement Lamps
Fixture Type
Lamp Type
Voltage
Base Type
Strobe
Xenon
All
Octal Socket
Catalog Number
S865
S865
Glass Globe
Catalog
Number
Clear
VPGL-1HR
Replacement Globes and Inserts
Insert
(in addition to Glass Globe)
Clear
59606060000
Amber
59606060001
Blue
59606060002
Green
59606060003
Red
59606060004
Dimensions
Pendant Mount
Ceiling Mount
7.00"/
177.8 mm
Wall Mount
10.63"/
270.0 mm
8.75"/
222.3 mm
5.25"/
133.4mm
7.00"/
177.8 mm
4.06"/
103.1mm
3.56"/
90.4 mm
3.05"/
77.5 mm
3.31"/
84.1mm
9.13"/
231.9mm
9.13"/
231.9mm
9.39"/
238.5 mm
6.08"/
154.4mm
4.75”/
120.7 mm
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
1.88” /
47.8 mm
4.06” /
103.1 mm
4.75”/
120.7 mm
1.88” /
47.8 mm
4.06” /
103.1 mm
1183
Lighting: Enclosed and Gasketed — Visual Signal
Replacement Parts
Mercmaster™ III Emergency Battery Pack
Enclosed and Gasketed. For Hazardous and Wet Locations
Simultaneous Exposure
Class I, Division 2, Class II, Division 1
Class I, Division 2, Group A, B, C, D
Class II, Division 1 and 2, Groups E, F, G
Class III
Wet Locations
NEMA 4X
Lighting: Enclosed and Gasketed — Emergency
Lighting
Applications
• Auxiliary (emergency) lighting should be used to provide a
lighted means of egress for personnel in walkways, catwalks,
stairs, doorways, tunnels, ramps and aisles.
• Auxiliary (emergency) lighting should be used to provide
“instant on” illumination during power failures.
• Enclosed and gasketed fixtures are suitable for normal
and emergency use in wet locations and in a wide range
of industrial, chemical processing and other areas where
flammable gases and vapors or combustible dusts are
present under conditions defined by NEC Class I, Division 2;
Class II, Division 1 and 2; and Class III.
• Suitability includes listing for normal and emergency use
where there may be simultaneous exposure to combustible
dusts and flammable gases and vapors.
• Fixtures are also well suited for normal and emergency
use in non-hazardous areas where severe weather
conditions, excessive moisture, dirt, dust or corrosive
atmospheres are encountered.
• Typical applications include pulp and paper mills, processing
plants, chemical plants, oil refineries, foundries, manufacturing
plants and storage areas.
Features
• Modular design allows scores of fixture component
combinations to meet installation and lighting needs.
• Choice of optical assemblies: (1) prismatic globe; (2) enclosed
reflector with sealed lens; and (3) Type V or Type II closed
prismatic refractor, with or without guard.
• Fluorescent light source reduces energy costs.
• Fluorescent lamp life of 10,000 hours reduces relamping
costs compared to incandescent.
• Mounting hoods include cone-shaped pendant, standard
pendant, ceiling and wall (tapped for 3/4” or 1” NPT), 25°
angle stanchion and straight stanchion (both tapped for
1-1/4” or 1-1/2” NPT).
• Cone hood fixtures for pendant mounting shed dust, dirt
and combustible fibers. Inhibits build-up that “insulates”
fixture and slows heat transfer. Also provides increased
surface area for more effective heat dissipation.
• Reflector choice includes standard dome and 30° angle
types, both made of fiberglass reinforced white polyester.
Highly resistant to unusually corrosive applications. Reflectors
are vented for cooler, dirt-free operation and maintained lumen
output. They secure to ballast housing with stainless steel
screws, threading into stainless steel inserts.
• For high corrosion resistance, fixture housing, mounting
hoods and guards are diecast copperfree (4/10 of 1% max.)
aluminum with baked epoxy finish, electrostatically applied for
uniformity.
All exposed hardware is stainless steel.
• Hinge has high lip for added safety during installation
and servicing. Hinge and bolt construction assures 360°
compression at all points on ballast housing gasket for
positive sealing. Swing-away design of captive bolt and
nut simplifies servicing.
• Body gaskets and globe gaskets are high-temperature
silicone rubber.
• All Mercmaster III mounting hoods have provision for easy
field installation of fuses in fixtures (see fuse kit listing in this
catalog section).
1184
Prismatic Glass Globe
12” Glass Refractor
Enclosed Reflector
• “Instant on” nature of the fluorescent light source prevents the
possibility of a complete blackout due to power failure.
• Fixture (26 W or 52 W) is available for emergency operation (one
battery pack provides illumination only during power outage).
• Fixture (26 W or 52 W) is available for continuous operation
(one AC ballast permits illumination when AC power is on and
one battery pack permits illumination when AC power
is interrupted).
• Fixture (26 W, 52 W, 64 W or 84 W) is available for
semi-continuos operation (one AC ballast permits illumination
when power is on and one battery pack permits one lamp
illumination when AC power is interrupted).
• For electrical protection, a ground wire is provided on each
Mercmaster to bond hood and ballast housing.
• Minimum operating temperature: 0 °C/32 °F.
• Maximum operating temperature: 40 °C/104 °F.
Battery Pack Information
•
•
•
•
Sealed, maintenance-free, high-temperature nickel-cadmium.
Solid state chargers sealed within the ballast case.
10 year life expectancy.
Wiring instructions for “Push-To-Test” button are supplied
with fixture.
• Remote “Push-To-Test” switch is available to verify emergency
operation (order separately, see F3-82).
• Red indicator light is provided with each battery pack to indicate
when the battery is charging.
Standard Materials
• Mounting hoods, ballast bodies and guard: diecast
cooper-free aluminum (less than 4/10 of 1%)
• Exposed hardware: stainless steel; latch assemblies have
stainless steel bolt and captive nut; reflectors and guards attach
with stainless steel screws threading into stainless steel inserts
• Reflectors: fiberglass reinforced white polyester
• Globe: heat- and impact-resistant internally fluted glass
• Refractors: prismatic glass
• Enclosed reflector: etched aluminum with sealed,
tempered heat- and impact-resistant lens
• Guards: stainless steel
• Breather: stainless steel
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
Mercmaster™ III Emergency Battery Pack
Enclosed and Gasketed. For Hazardous and Wet Locations
Simultaneous Exposure
Class I, Division 2, Class II, Division 1
Class I, Division 2, Group A, B, C, D
Class II, Division 1 and 2, Groups E, F, G
Class III
Wet Locations
NEMA 4X
Standard Finishes
Certifications and Compliances
• UL Standard: UL 1598, UL 924, UL 844
• UL Listed: E10444
• NFPA101, Life Safety Code
Lighting
• Mounting hoods, ballast bodies, guards: baked gray
epoxy-clad finish, electrostatically applied for complete,
uniform surface protection
• Reflectors: white polyester finish
Options
• Fuses can be field-installed on Mercmaster III fixtures. Kit
includes fuse block, wire connectors and screws for attaching to
mounting hood.
Lighting: Enclosed and Gasketed — Emergency
Order using catalog numbering guide below or select catalog number from tables on following pages.
Catalog Numbering Guide
KP
A
Series:
KP - Class I,
Division 2
Groups A,B,C,D
Class II, Division 1
and 2
Groups E,F,G
Class III
F
Lamp Type:
F - Fluorescent
Mounting Hood:
A - Pendant
C - Ceiling
D - Pendant Cone
F - Flexible Pendant
R - 90° Stanchion
S - 25° Stanchion
W - Wall
26
C
2
Circuit Type:
C - Continuous
Operation
(provided with 1
AC Ballast and 1
Battery Pack).
26 W and 52 W
E- Emergency
Operation
(provided with 1
Battery Pack).
26 W and 52 W
only
S - SemiContinuous
(provided with 1
AC Ballast and 1
Battery Pack).
26 W, 52 W, 64 W
and 84 W
Lamp Wattage:
26 - 26 W (Two 13 W Lamps)
52 - 52 W (Two 26 W Lamps)
64 - 64 W (Two 32 W Lamps)
84 - 84 W (Two 42 W Lamps)
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
Hub Size:
2 - 3/4”
3 - 1”
4 - 1-1/4”
5 - 1-1/2”
G4
G
Optic:
G4 - Globe
R - Enclosed
Reflector with
Sealed Lens
J2 - NEMA II
Refractor
J5 - NEMA V
Refractor
BU
L
Voltage:
120 through 277 Volt
50/60 Hz
Guard Option:
G - Guard
N - No Guard
Lamps:
L - Lamps provided
1185
Mercmaster™ III Emergency Battery Pack
Enclosed and Gasketed. For Hazardous and Wet Locations
Simultaneous Exposure
Class I, Division 2, Class II, Division 1
Class I, Division 2, Group A, B, C, D
Class II, Division 1 and 2, Groups E, F, G
Class III
Wet Locations
NEMA 4X
Lighting: Enclosed and Gasketed — Emergency
Lighting
Illustrated Features
Vented Reflectors
Reflectors are thick, tough fiberglass-
reinforced white polyester, vented for
cooler operation. Quickly attach with
furnished stainless steel screws.
Aluminum Inner Reflector
Solid aluminum inner reflector improves
photometric efficiency.
Epoxy Finish
Ballast housing, hoods and guards are
copperfree aluminum with epoxy powder
coat finish.
"Safety" High
Hinge
Extra-high hinge
provides additional
protection against
accidental
ballast housing
disengagement
during installation
or maintenance.
Stainless Steel
Latch Assembly
Captive, stainless
steel latch assembly
bolt and nut closes
securely, resists
attack of corrosive
atmospheres.
Swing-away design
simplifies servicing.
Stainless Steel Inserts
Ballast bodies have stainless steel
threaded inserts to receive stainless steel
screws for reflectors and guard. Prevents
"freezing”, allowing guards and reflectors
to be easily removed and replaced at any
time, without damage to the housing.
Hood/Ballast Gasket
Silicone rubber gasket seals out moisture,
dirt and dust. Stays flexible, withstands
high temperatures. Closure design
assures uniform gasket compression.
Electrical Protection
Ground wire provided to bond mounting
hood to ballast housing.
Prismatic Glass Globes, Refractors
and Enclosed Reflector
Heat-resistant globes, refractors and
enclosed reflector thread into ballast
housing and seal against a high
temperature silicone rubber gasket.
Cooler Operating Cone Hood
Larger sloped surface sheds dusts, dirt
and combustible fibers providing better
heat dissipation.
Fuses
Two screws secure fuse kit to mounting
boss in any Mercmaster mounting hood.
Fuse included.
1186
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
Mercmaster™ III Emergency Battery Pack Technical Data
Enclosed and Gasketed. For Hazardous and Wet Locations
Simultaneous Exposure
Class I, Division 2, Class II, Division 1
Class I, Division 2, Group A, B, C, D
Class II, Division 1 and 2, Groups E, F, G
Class III
Wet Locations
NEMA 4X
Electrical Specification for AC Operation
Frequency (Hz)
Type of Ballast
Line Amps (A)
Maximum Wattage (W/W)
Catalog Number
26 W (2X 13 W)
120-277
50/60
Electronic (PLT)
0.26-0.11
30/30
KPBC26FBU
26 W (2X 13 W)
120-277
50/60
Electronic (PLT)
0.26-0.11
30/30
KPBE26FBU
26 W (2X 13 W)
120-277
50/60
Electronic (PLT)
0.26-0.11
30/30
KPBS26FBU
52 W (2X 26 W)
120-277
50/60
Electronic (PLT)
0.46-0.20
56/55
KPBC52FBU
52 W (2X 26 W)
120-277
50/60
Electronic (PLT)
0.46-0.20
56/55
KPBE52FBU
52 W (2X 26 W)
120-277
50/60
Electronic (PLT)
0.46-0.20
56/55
KPBS52FBU
64 W (2X 32 W)
120-277
50/60
Electronic (PLT)
0.58-0.26
69/67
KPBS64FBU
84 W (2X 42 W)
120-277
50/60
Electronic (PLT)
0.76-0.32
91/90
KPBS84FBU
Thermal Performance of Mercmaster III Emergency Battery Pack Fixtures
Lamp
Watts
Ambient
Temp.
(°F/°C)
Group
26 W (2 x 13 W)
104/40
A,B,C,D
52 W (2 x 26 W)
104/40
64 W (2 x 32 W)
84 W (2 x 42 W)
Hazardous
Rating
Class I, Division 2
Class II, Division 1
Simultaneous
Exposure
Class I, Division 2 /
Class II, Division 1
Refractor
Enclosed
Reflector
Supply Wire
Suitability
(°F/°C)
T2D
T2D
167/75
T2D
T2D
T2D
167/75
T2D
T2D
T2D
T2D
167/75
T2D
T2D
T2D
T2D
167/75
E,F,G
T3B
T3B
T4
T4A
194/90
104/40
E,F,G
T3B
T3B
T4
T4A
194/90
64 W (2 x 32 W)
104/40
E,F,G
T3B
T3B
T4
T4A
194/90
84 W (2 x 42 W)
104/40
E,F,G
T3B
T3B
T4
T4A
194/90
26 W (2 x 13 W)
104/40
—
T1
T1
T2
T2B
230/110
52 W (2 x 26 W)
104/40
—
T1
T1
T2
T2B
230/110
64 W (2 x 32 W)
104/40
—
T1
T1
T2
T2B
230/110
84 W (2 x 42 W)
104/40
—
T1
T1
T2
T2B
230/110
Globe
Globe w/
Reflector
T2D
T2D
A,B,C,D
T2D
104/40
A,B,C,D
104/40
A,B,C,D
26 W (2 x 13 W)
104/40
52 W (2 x 26 W)
“T” Numbers Represent the Maximum Lamp Temperature for Class I, Division 2 Locations and Maximum
Surface Temperature Under Dust Blanket for Class II, Division 1 Locations.
“T”
Number
T1
350
325
T2
T2A
T2B
T2C
T2D
T3
T3A
T3B
T3C
T4
T4A
T5
T6
Temp.
Range
(˚ºF)
664842
619662
574617
538572
502536
448500
421446
394419
358392
331356
322329
277320
250275
214248
187212
185
Temp
Range
(°C)
351450
326350
301325
281300
261280
231260
216230
201215
181200
166180
161165
136160
121135
101120
86-100
85
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
1187
Lighting: Enclosed and Gasketed — Emergency
Line Voltage (V)
Lighting
Fixture Wattage
Mercmaster™ III Emergency Battery Pack
Enclosed and Gasketed. For Hazardous and Wet Locations
Simultaneous Exposure
Class I, Division 2, Class II, Division 1
Class I, Division 2, Group A, B, C, D
Class II, Division 1 and 2, Groups E, F, G
Class III
Lighting: Enclosed and Gasketed — Emergency
Lighting
Lamp Hub Size
Watts (Inches)
Pendant ➍
Pendant Cone
Ceiling
Wall
90° Stanchion
25° Stanchion
Wet Locations
NEMA 4X
Mode of
Operation
Volts
Hz
with Globe ➊➋
Catalog Numbers
with Type V 12” Refractor
➊➋➌
with Enclosed
Reflector ➊➋➌
26
3/4
Continuous
120-277
50/60
KPAF26C2G4NBUL
KPAF26C2J5NBUL
KPAF26C2RNBUL
26
1
Continuous
120-277
50/60
KPAF26C3G4NBUL
KPAF26C3J5NBUL
KPAF26C3RNBUL
26
3/4
Semi-Continuous 120-277
50/60
KPAF26S2G4NBUL
KPAF26S2J5NBUL
KPAF26S2RNBUL
26
1
Semi-Continuous 120-277
50/60
KPAF26S3G4NBUL
KPAF26S3J5NBUL
KPAF26S3RNBUL
26
3/4
120-277
50/60
KPAF26E2G4NBUL
KPAF26E2J5NBUL
KPAF26E2RNBUL
Emergency
26
1
Emergency
120-277
50/60
KPAF26E3G4NBUL
KPAF26E3J5NBUL
KPAF26E3RNBUL
26
3/4
Continuous
120-277
50/60
KPDF26C2G4NBUL
KPDF26C2J5NBUL
KPDF26C2RNBUL
26
1
Continuous
120-277
50/60
KPDF26C3G4NBUL
KPDF26C3J5NBUL
KPDF26C3RNBUL
26
3/4
Semi-Continuous 120-277
50/60
KPDF26S2G4NBUL
KPDF26S2J5NBUL
KPDF26S2RNBUL
26
1
Semi-Continuous 120-277
50/60
KPDF26S3G4NBUL
KPDF26S3J5NBUL
KPDF26S3RNBUL
26
3/4
KPDF26E2G4NBUL
KPDF26E2J5NBUL
KPDF26E2RNBUL
Emergency
120-277
50/60
26
1
Emergency
120-277
50/60
KPDF26E3G4NBUL
KPDF26E3J5NBUL
KPDF26E3RNBUL
26
3/4
Continuous
120-277
50/60
KPCF26C2G4NBUL
KPCF26C2J5NBUL
KPCF26C2RNBUL
26
1
Continuous
120-277
50/60
KPCF26C3G4NBUL
KPCF26C3J5NBUL
KPCF26C3RNBUL
26
3/4
Semi-Continuous 120-277
50/60
KPCF26S2G4NBUL
KPCF26S2J5NBUL
KPCF26S2RNBUL
26
1
Semi-Continuous 120-277
50/60
KPCF26S3G4NBUL
KPCF26S3J5NBUL
KPCF26S3RNBUL
26
3/4
KPCF26E2G4NBUL
KPCF26E2J5NBUL
KPCF26E2RNBUL
Emergency
120-277
50/60
26
1
Emergency
120-277
50/60
KPCF26E3G4NBUL
KPCF26E3J5NBUL
KPCF26E3RNBUL
26
3/4
Continuous
120-277
50/60
KPWF26C2G4NBUL
KPWF26C2J5NBUL
KPWF26C2RNBUL
Continuous
26
1
120-277
50/60
KPWF26C3G4NBUL
KPWF26C3J5NBUL
KPWF26C3RNBUL
26
3/4
Semi-Continuous 120-277
50/60
KPWF26S2G4NBUL
KPWF26S2J5NBUL
KPWF26S2RNBUL
26
1
Semi-Continuous 120-277
50/60
KPWF26S3G4NBUL
KPWF26S3J5NBUL
KPWF26S3RNBUL
26
3/4
Emergency
120-277
50/60
KPWF26E2G4NBUL
KPWF26E2J5NBUL
KPWF26E2RNBUL
26
1
Emergency
120-277
50/60
KPWF26E3G4NBUL
KPWF26E3J5NBUL
KPWF26E3RNBUL
26
1-1/4
Continuous
120-277
50/60
KPRF26C4G4NBUL
KPRF26C4J5NBUL
KPRF26C4RNBUL
26
1-1/2
Continuous
120-277
50/60
KPRF26C5G4NBUL
KPRF26C5J5NBUL
KPRF26C5RNBUL
26
1-1/4 Semi-Continuous 120-277
50/60
KPRF26S4G4NBUL
KPRF26S4J5NBUL
KPRF26S4RNBUL
26
1-1/2 Semi-Continuous 120-277
50/60
KPRF26S5G4NBUL
KPRF26S5J5NBUL
KPRF26S5RNBUL
26
1-1/4
Emergency
120-277
50/60
KPRF26E4G4NBUL
KPRF26E4J5NBUL
KPRF26E4RNBUL
26
1-1/2
Emergency
120-277
50/60
KPRF26E5G4NBUL
KPRF26E5J5NBUL
KPRF26E5RNBUL
26
1-1/4
Continuous
120-277
50/60
KPSF26C4G4NBUL
KPSF26C4J5NBUL
KPSF26C4RNBUL
26
1-1/2
Continuous
120-277
50/60
KPSF26C5G4NBUL
KPSF26C5J5NBUL
KPSF26C5RNBUL
26
1-1/4 Semi-Continuous 120-277
50/60
KPSF26S4G4NBUL
KPSF26S4J5NBUL
KPSF26S4RNBUL
26
1-1/2 Semi-Continuous 120-277
50/60
KPSF26S5G4NBUL
KPSF26S5J5NBUL
KPSF26S5RNBUL
26
1-1/4
Emergency
120-277
50/60
KPSF26E4G4NBUL
KPSF26E4J5NBUL
KPSF26E4RNBUL
26
1-1/2
Emergency
120-277
50/60
KPSF26E5G4NBUL
KPSF26E5J5NBUL
KPSF26E5RNBUL
NOTE: “Continuous operation” means 2 lamps operate when AC power is present and continue to operate during AC power failure. “Emergency operation”
means lamps do not operate when AC power is present, but 2 lamps operate from the DC battery pack only during AC power failure. “Semi-continuous” means 2
lamps operate when AC power is present and 1 lamp continues to operate during AC power failure.
➊ For fixtures with guard, substitute G for N before adding voltage suffix.
➋ Lamp included as standard.
➌ To order fixture with NEMA type 2 refractor, change final digit J5 in catalog number to J2.
➍ One hub, rigid or flexible mounting.
1188
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
Mercmaster™ III Emergency Battery Pack
Enclosed and Gasketed. For Hazardous and Wet Locations
Simultaneous Exposure
Class I, Division 2, Class II, Division 1
Class I, Division 2, Group A, B, C, D
Class II, Division 1 and 2, Groups E, F, G
Class III
Lamp Hub Size
Watts (Inches)
Ceiling
Wall
90° Stanchion
25° Stanchion
Volts
Hz
with Globe ➊➋
Catalog Numbers
with Type V 12” Refractor
➊➋➌
with Enclosed
Reflector ➊➋➌
52
3/4
Continuous
120-277
50/60
KPAF52C2G4NBUL
KPAF52C2J5NBUL
KPAF52C2RNBUL
52
1
Continuous
120-277
50/60
KPAF52C3G4NBUL
KPAF52C3J5NBUL
KPAF52C3RNBUL
52
3/4
Semi-Continuous 120-277
50/60
KPAF52S2G4NBUL
KPAF52S2J5NBUL
KPAF52S2RNBUL
52
1
Semi-Continuous 120-277
50/60
KPAF52S3G4NBUL
KPAF52S3J5NBUL
KPAF52S3RNBUL
52
3/4
KPAF52E2G4NBUL
KPAF52E2J5NBUL
KPAF52E2RNBUL
Emergency
120-277
50/60
52
1
Emergency
120-277
50/60
KPAF52E3G4NBUL
KPAF52E3J5NBUL
KPAF52E3RNBUL
52
3/4
Continuous
120-277
50/60
KPDF52C2G4NBUL
KPDF52C2J5NBUL
KPDF52C2RNBUL
52
1
Continuous
120-277
50/60
KPDF52C3G4NBUL
KPDF52C3J5NBUL
KPDF52C3RNBUL
52
3/4
Semi-Continuous 120-277
50/60
KPDF52S2G4NBUL
KPDF52S2J5NBUL
KPDF52S2RNBUL
52
1
Semi-Continuous 120-277
50/60
KPDF52S3G4NBUL
KPDF52S3J5NBUL
KPDF52S3RNBUL
52
3/4
KPDF52E2G4NBUL
KPDF52E2J5NBUL
KPDF52E2RNBUL
Emergency
120-277
50/60
52
1
Emergency
120-277
50/60
KPDF52E3G4NBUL
KPDF52E3J5NBUL
KPDF52E3RNBUL
52
3/4
Continuous
120-277
50/60
KPCF52C2G4NBUL
KPCF52C2J5NBUL
KPCF52C2RNBUL
52
1
Continuous
120-277
50/60
KPCF52C3G4NBUL
KPCF52C3J5NBUL
KPCF52C3RNBUL
52
3/4
Semi-Continuous 120-277
50/60
KPCF52S2G4NBUL
KPCF52S2J5NBUL
KPCF52S2RNBUL
52
1
Semi-Continuous 120-277
50/60
KPCF52S3G4NBUL
KPCF52S3J5NBUL
KPCF52S3RNBUL
52
3/4
Emergency
120-277
50/60
KPCF52E2G4NBUL
KPCF52E2J5NBUL
KPCF52E2RNBUL
52
1
Emergency
120-277
50/60
KPCF52E3G4NBUL
KPCF52E3J5NBUL
KPCF52E3RNBUL
52
3/4
Continuous
120-277
50/60
KPWF52C2G4NBUL
KPWF52C2J5NBUL
KPWF52C2RNBUL
Continuous
52
1
120-277
50/60
KPWF52C3G4NBUL
KPWF52C3J5NBUL
KPWF52C3RNBUL
52
3/4
Semi-Continuous 120-277
50/60
KPWF52S2G4NBUL
KPWF52S2J5NBUL
KPWF52S2RNBUL
52
1
Semi-Continuous 120-277
50/60
KPWF52S3G4NBUL
KPWF52S3J5NBUL
KPWF52S3RNBUL
52
3/4
Emergency
120-277
50/60
KPWF52E2G4NBUL
KPWF52E2J5NBUL
KPWF52E2RNBUL
52
1
Emergency
120-277
50/60
KPWF52E3G4NBUL
KPWF52E3J5NBUL
KPWF52E3RNBUL
52
1-1/4
Continuous
120-277
50/60
KPRF52C4G4NBUL
KPRF52C4J5NBUL
KPRF52C4RNBUL
52
1-1/2
Continuous
120-277
50/60
KPRF52C5G4NBUL
KPRF52C5J5NBUL
KPRF52C5RNBUL
52
1-1/4 Semi-Continuous 120-277
50/60
KPRF52S4G4NBUL
KPRF52S4J5NBUL
KPRF52S4RNBUL
52
1-1/2 Semi-Continuous 120-277
50/60
KPRF52S5G4NBUL
KPRF52S5J5NBUL
KPRF52S5RNBUL
52
1-1/4
Emergency
120-277
50/60
KPRF52E4G4NBUL
KPRF52E4J5NBUL
KPRF52E4RNBUL
52
1-1/2
Emergency
120-277
50/60
KPRF52E5G4NBUL
KPRF52E5J5NBUL
KPRF52E5RNBUL
52
1-1/4
Continuous
120-277
50/60
KPSF52C4G4NBUL
KPSF52C4J5NBUL
KPSF52C4RNBUL
52
1-1/2
Continuous
120-277
50/60
KPSF52C5G4NBUL
KPSF52C5J5NBUL
KPSF52C5RNBUL
52
1-1/4 Semi-Continuous 120-277
50/60
KPSF52S4G4NBUL
KPSF52S4J5NBUL
KPSF52S4RNBUL
52
1-1/2 Semi-Continuous 120-277
50/60
KPSF52S5G4NBUL
KPSF52S5J5NBUL
KPSF52S5RNBUL
52
1-1/4
Emergency
120-277
50/60
KPSF52E4G4NBUL
KPSF52E4J5NBUL
KPSF52E4RNBUL
52
1-1/2
Emergency
120-277
50/60
KPSF52E5G4NBUL
KPSF52E5J5NBUL
KPSF52E5RNBUL
NOTE: “Continuous operation” means 2 lamps operate when AC power is present and continue to operate during AC power failure. “Emergency operation”
means lamps do not operate when AC power is present, but 2 lamps operate from the DC battery pack only during AC power failure. “Semi-continuous” means 2
lamps operate when AC power is present and 1 lamp continues to operate during AC power failure.
➊ For fixtures with guard, substitute G for N before adding voltage suffix.
➋ Lamp included as standard.
➌ To order fixture with NEMA type 2 refractor, change final digit J5 in catalog number to J2.
➍ One hub, rigid or flexible mounting.
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
1189
Lighting: Enclosed and Gasketed — Emergency
Pendant Cone
Mode of
Operation
Lighting
Pendant ➍
Wet Locations
NEMA 4X
Mercmaster™ III Emergency Battery Pack
Enclosed and Gasketed. For Hazardous and Wet Locations
Simultaneous Exposure
Class I, Division 2, Class II, Division 1
Class I, Division 2, Group A, B, C, D
Class II, Division 1 and 2, Groups E, F, G
Class III
Lighting: Enclosed and Gasketed — Emergency
Lighting
Lamp Hub Size
Watts (Inches)
Pendant ➍
Pendant Cone
Ceiling
Wall
90° Stanchion
25° Stanchion
Wet Locations
NEMA 4X
Mode of
Operation
Volts
Hz
with Globe ➊➋
Catalog Numbers
with Type V 12” Refractor
➊➋➌
with Enclosed
Reflector ➊➋➌
64
3/4
Semi-Continuous 120-277
50/60
KPAF64S2G4NBUL
KPAF64S2J5NBUL
KPAF64S2RNBUL
64
1
Semi-Continuous 120-277
50/60
KPAF64S3G4NBUL
KPAF64S3J5NBUL
KPAF64S3RNBUL
64
3/4
Semi-Continuous 120-277
50/60
KPDF64S2G4NBUL
KPDF64S2J5NBUL
KPDF64S2RNBUL
64
1
Semi-Continuous 120-277
50/60
KPDF64S3G4NBUL
KPDF64S3J5NBUL
KPDF64S3RNBUL
64
3/4
Semi-Continuous 120-277
50/60
KPCF64S2G4NBUL
KPCF64S2J5NBUL
KPCF64S2RNBUL
64
1
Semi-Continuous 120-277
50/60
KPCF64S3G4NBUL
KPCF64S3J5NBUL
KPCF64S3RNBUL
64
3/4
Semi-Continuous 120-277
50/60
KPWF64S2G4NBUL
KPWF64S2J5NBUL
KPWF64S2RNBUL
64
1
Semi-Continuous 120-277
50/60
KPWF64S3G4NBUL
KPWF64S3J5NBUL
KPWF64S3RNBUL
64
1-1/4 Semi-Continuous 120-277
50/60
KPRF64S4G4NBUL
KPRF64S4J5NBUL
KPRF64S4RNBUL
64
1-1/2 Semi-Continuous 120-277
50/60
KPRF64S5G4NBUL
KPRF64S5J5NBUL
KPRF64S5RNBUL
64
1-1/4 Semi-Continuous 120-277
50/60
KPSF64S4G4NBUL
KPSF64S4J5NBUL
KPSF64S4RNBUL
64
1-1/2 Semi-Continuous 120-277
50/60
KPSF64S5G4NBUL
KPSF64S5J5NBUL
KPSF64S5RNBUL
NOTE: “Continuous operation” means 2 lamps operate when AC power is present and continue to operate during AC power failure. “Emergency operation”
means lamps do not operate when AC power is present, but 2 lamps operate from the DC battery pack only during AC power failure. “Semi-continuous” means 2
lamps operate when AC power is present and 1 lamp continues to operate during AC power failure.
➊ For fixtures with guard, substitute G for N before adding voltage suffix.
➋ Lamp included as standard.
➌ To order fixture with NEMA type 2 refractor, change final digit J5 in catalog number to J2.
➍ One hub, rigid or flexible mounting.
1190
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
Mercmaster™ III Emergency Battery Pack
Enclosed and Gasketed. For Hazardous and Wet Locations
Simultaneous Exposure
Class I, Division 2, Class II, Division 1
Class I, Division 2, Group A, B, C, D
Class II, Division 1 and 2, Groups E, F, G
Class III
Lamp Hub Size
Watts (Inches)
Ceiling
Wall
90° Stanchion
25° Stanchion
Volts
Hz
with Globe ➊➋
Catalog Numbers
with Type V 12” Refractor
➊➋➌
with Enclosed
Reflector ➊➋➌
84
3/4
Semi-Continuous 120-277
50/60
KPAF84S2G4NBUL
KPAF84S2J5NBUL
KPAF84S2RNBUL
84
1
Semi-Continuous 120-277
50/60
KPAF84S3G4NBUL
KPAF84S3J5NBUL
KPAF84S3RNBUL
84
3/4
Semi-Continuous 120-277
50/60
KPDF84S2G4NBUL
KPDF84S2J5NBUL
KPDF84S2RNBUL
84
1
Semi-Continuous 120-277
50/60
KPDF84S3G4NBUL
KPDF84S3J5NBUL
KPDF84S3RNBUL
84
3/4
Semi-Continuous 120-277
50/60
KPCF84S2G4NBUL
KPCF84S2J5NBUL
KPCF84S2RNBUL
84
1
Semi-Continuous 120-277
50/60
KPCF84S3G4NBUL
KPCF84S3J5NBUL
KPCF84S3RNBUL
84
3/4
Semi-Continuous 120-277
50/60
KPWF84S2G4NBUL
KPWF84S2J5NBUL
KPWF84S2RNBUL
84
1
Semi-Continuous 120-277
50/60
KPWF84S3G4NBUL
KPWF84S3J5NBUL
KPWF84S3RNBUL
84
1-1/4 Semi-Continuous 120-277
50/60
KPRF84S4G4NBUL
KPRF84S4J5NBUL
KPRF84S4RNBUL
84
1-1/2 Semi-Continuous 120-277
50/60
KPRF84S5G4NBUL
KPRF84S5J5NBUL
KPRF84S5RNBUL
84
1-1/4 Semi-Continuous 120-277
50/60
KPSF84S4G4NBUL
KPSF84S4J5NBUL
KPSF84S4RNBUL
84
1-1/2 Semi-Continuous 120-277
50/60
KPSF84S5G4NBUL
KPSF84S5J5NBUL
KPSF84S5RNBUL
NOTE: “Continuous operation” means 2 lamps operate when AC power is present and continue to operate during AC power failure. “Emergency operation”
means lamps do not operate when AC power is present, but 2 lamps operate from the DC battery pack only during AC power failure. “Semi-continuous” means 2
lamps operate when AC power is present and 1 lamp continues to operate during AC power failure.
➊ For fixtures with guard, substitute G for N before adding voltage suffix.
➋ Lamp included as standard.
➌ To order fixture with NEMA type 2 refractor, change final digit J5 in catalog number to J2.
➍ One hub, rigid or flexible mounting.
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
1191
Lighting: Enclosed and Gasketed — Emergency
Pendant Cone
Mode of
Operation
Lighting
Pendant ➍
Wet Locations
NEMA 4X
Mercmaster™ III Emergency Battery Pack Mounting Hoods and Ballast Bodies
Enclosed and Gasketed. For Hazardous and Wet Locations
Simultaneous Exposure
Class I, Division 2, Class II, Division 1
Class I, Division 2, Group A, B, C, D
Class II, Division 1 and 2, Groups E, F, G
Class III
Wet Locations
NEMA 4X
Mounting Hoods
Description
Hub Size (Inches)
Catalog Number
Lighting
Pendant
One Hub, Rigid Mounting
One Hub, Flexible Mounting
3/4
KPA-75
1
KPA-100
3/4
KPAF-75
1
KPAF-100
3/4
KPCH-75
1
KPCH-100
3/4
KPC-75
1
KPC-100
3/4
KPWB-75
1
KPWB-100
1-1/4
KPS-125
1-1/2
KPS-150
1-1/4
KPST-125
1-1/2
KPST-150
Lighting: Enclosed and Gasketed — Emergency
Pendant Cone
One Hub,
Rigid Mounting
Ceiling
Five Hubs,
Four Close-Up Plugs
Wall
Five Hubs,
Four Close-Up Plugs
25° Stanchion
One Hub
90° Stanchion
One Hub
Ballast Bodies
1192
Lamp
Wattage
Mode of Operation
Voltage
Hz
Ballast Body
Catalog Number
26
Continuous
120-277
50/60
KPBC26FBU
26
Emergency
120-277
50/60
KPBE26FBU
26
Semi Continuous
120-277
50/60
KPBS26FBU
52
Continuous
120-277
50/60
KPBC52FBU
52
Emergency
120-277
50/60
KPBE52FBU
52
Semi Continuous
120-277
50/60
KPBS52FBU
64
Semi-Continuous
120-277
50/60
KPBS64FBU
84
Semi-Continuous
120-277
50/60
KPBS84FBU
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
Mercmaster™ III Emergency Battery Pack Accessories
Enclosed and Gasketed. For Hazardous and Wet Locations
Simultaneous Exposure
Class I, Division 2, Class II, Division 1
Class I, Division 2, Group A, B, C, D
Class II, Division 1 and 2, Groups E, F, G
Class III
Item
Wet Locations
NEMA 4X
Description
Catalog Number
White Polyester Reflectors
For use with globe fixtures
mm
Standard Dome17.
18.70"
06
"
18.70"
17
CMR4-ST *
30° Angle
CMR4-AN
Lighting
117
.06 4337.0.066"
.3 "/
"
17
18.70"/
18.70" 18.70"
475.0 mm
Standard Dome
30°
Angle
7-11/16"
7-11/16"
"
.06
Prismatic Glass Globes
7-11/16"
11-5/16"11-5/16"
11-5/16"
11.31”11-5/16"
/287.3
Heat-resistant
Lighting: Enclosed and Gasketed — Emergency
7.69"
/195.3 mm
7-11/16"
VPGL-4HR
Clear
mm
6-1/4" 6-1/4"
6-1/4"
6.25”
/158.8
mm 7.69"
6-1/4" 7.69"
Closed Prismatic Glass
Refractors
7.69"
7.69" mm
7.69”/195.3
11.50" 11.50"
11.50"
11.50"
11.58”/294.1 mm
NEMA Type II
KPRF400-2
NEMA Type V
KPRF400-5
Heat- and impact-resistant glass lens
KPR-4HB
Globe Guard
KPGU400
Refractor Guard
KPBG12
Enclosed Reflector Guard
GHB7000-NG
12.05" 12.05"
12.05"
12.05”/306.1
12.05"
mm
7.69”/195.3
7.69"
mm
Enclosed Reflector Assembly
7.69" 7.69"
7.69"
11.50"
16.38"
11.50" 11.50"
11.50"
11.50”/292.1
mm
16.38"
16.38"
16.38"
16.38”/
416.1mm
Stainless Steel Guards
Globe
Refractor
Enclosed Reflector
Photocontrol
Factory-Installed †
Voltage Range
Mercmaster III Wall Mounting with
Photocontrol Factory Installed
Field-Installed
Suffix Designation
120 V, 50/60 Hz
H1
208 V, 50/60 Hz
H2
240 V, 50/60 Hz
H3
277 V, 50/60 Hz
H4
Max. Current
Voltage Range
Catalog Number
8.3 A
120 V, 50/60 Hz
PC120D2
3.5 A
208-277 V, 50/60 Hz
PC247D2
Photocontrol for Field Installation
* Consult factory if used with KPWB or KPST mounting hoods.
† Add to fixture catalog after voltage; i.e.: KPWF26C2G4NBULH1.
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
1193
Mercmaster™ III Emergency Battery Pack Accessories
Enclosed and Gasketed. For Hazardous and Wet Locations
Item
Description
Catalog Number
Three-Way Exit Sign
EXR400
Lighting
Epoxy enameled steel — 10” high red lettering
Mounts to fixture units in place of guard
Replacement Optic Gaskets
Silicone Rubber
KRF-GK
Lighting: Enclosed and Gasketed — Emergency
Globe, Refractor and
Enclosed Refractor Gasket
Replacement Lamp
PLC
PLT
Lamp Type
Lamp Base
Wattage
Catalog Number
PL-C
G24Q-1
13
PLC134
PL-T
G24q-4
26
PLT26
PL-T
G24q-4
32
PLT32
PL-T
G24q-4
42
PLT42
Replacement Socket
PLC
For 26 W (2 x 13 W) PLC Lamps
PLC13RS
For 26 W, 32 W and 42 W PLT Lamps listed above
PLT32RS
PLT
Retrofit Pendant Mounting Adapter
Permits use of Mercmaster III pendant hood with 3/4” hub on existing
V-51 mounting hood.
LPAD-1
Fuse Kit
2-amp time delay fuse
1194
F2
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
EFDB™ Factory Sealed Push-To-Test Station
Explosionproof, Dust-Ignitionproof
Applications
Description
Dead-End
Feed-Thru
1 Circuit
Universal
EFDB150-U1-TEST
EFDCB150-U1-TEST
EFDB175-U1-TEST
EFDCB175-U1-TEST
EFDB110-U1-TEST
EFDCB110-U1-TEST
Single Gang *
Momentary Contact
Features
1/2
3/4
1
Replacement Parts for Push-to-Test Switch
Description
Catalog Number
Complete Cover Assy
EFKB-U1-TEST
Push Button Only
SPBBU1Q
Test Legend Plate
SNPTESTQ
12-24 x 1 (4) Screws
B
A
4.63”/
117.6 mm
5.41”/
137.4 mm
6.38”/
162.1 mm
9/32 Dia.
Hole
2.31"/
58.7 mm
3.00”/
76.2 mm
5/16 Dia.
(2) Mtg.
Holes
5.00”/
127 mm
C
EFDB Single Gang Push-To-Test Control Station
Dimensions in Inches/Millimeters
B
Hub Size
(Inches)
A
1/2 & 3/4
5.38/136.7
6.13/155.7
0.78/19.8
1
5.50/139.7
6.31/160.3
0.94/23.9
C
* Malleable iron body and aluminum cover. For aluminum body, add suffix -A.
For Class I, Group B, external seals must be installed at each conduit entrance.
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
1195
Lighting: Enclosed and Gasketed — Emergency
• Eliminates need for adding sealing
fittings and compound at each conduit
entrance (Groups C and D).
• Heavy-duty, 10 ampere 600 V rated.
• Smooth, rounded integral bushing in
each EFDB hub protects conductor
insulation.
• Accurately tapped, tapered hubs for
tight, rigid joints and ground continuity.
• Stainless steel push button shaft
operators within stainless steel bushing
assures long, maintenance-free
operation.
• Push button contacts are silver
cadmium oxide which are “sealed”
in lower phenolic chamber isolated
from corrosive elements. Assures
positive contact and long, trouble-free
operation.
• Enclosed stainless steel helper spring
prevents accidental operation of push
button in severe vibration installations.
• Corrosion-resistant captive stainless
steel hex-head cap screws hold EFKB
cover to body.
• All EFDB front-operated push buttons
are supplied with lockout type guards
as standard. Hole in guard will accept
locks with up to 1/4” hasp. Permits
locking of push button to prevent
unauthorized operation.
• Clearly marked terminals with brass
screws assure quick, easy wiring.
Catalog Number
Hub Size
(Inches)
Lighting
• Push-to-test switch permits
interruption of AC power to fixture to
provide verification in an emergency
lighting system that battery packs and
lamps are functioning properly.
Mercmaster™ III Emergency Battery Pack Dimensions and Weights
Enclosed and Gasketed. For Hazardous and Wet Locations
Ceiling with Refractor
Enclosed Reflector and Guards
Pendant with Globe, Guard and Reflectors
Lighting
13.44"/
341.4 mm
13.44"/
341.4 mm
17.23"/
437.6 mm
11.21"/
284.7 mm
9.79"/
248.6 mm
11.82"/
300.2 mm
6.04" /
153.4 mm
11.65"/
295.9 mm
--1
7.0
6"
/4
33
.3
mm
10.35"/
262.9 mm
11.44"/
290.6 mm
12.38"/
314.5 mm
Dia
12.09"/
307.1 mm
10.38"/
263.7 mm
.
12.12"/
307.8 mm
18.70"/ 475.0 mm Dia.
16.38"/
416.1 mm
8.80"/
223.5 mm
12.25"/
311.2 mm Dia.
25° Stanchion
Wall
0.31"/
7.9 mm Dia
/
27" m
15. .9 m
7
8
3
Cone
17.00"/
431.8 mm
13.44"/
341.4 mm
5"/
9.2.0 mm "/
8
235 8.1 mm
.7
207
12 4.
0. 75
7 "/
m
m
4.06"/
103.1 mm
Lighting: Enclosed and Gasketed — Emergency
11.0"/
279.4 mm
10.25"/
260.4 mm
10.77"/
273.6 mm
90° Stanchion
/
07" m
12. .8 m
6
30
1.38"/
35.1 mm
13.08"/
332.2 mm
15.63"/
422.4 mm
12.12"/
307.8 mm
Mercmaster III – Emergency Ballast and Accessory Weights *
Ballast Housing (Wt. lbs/kg)
Lamp Watts
Continuous
SemiContinuous
Emergency
26
23.00/10.4
23.00/10.4
23.00/10.4
52
23.00/10.4
23.00/10.4
23.00/10.4
64
—
23.00/10.4
—
84
—
23.00/10.4
—
Mounting Hoods
Wt. (lbs/kg)
Refractor, Globe,
Reflector and Guards
Wt. (lbs/kg)
Pendant
2.25/1.0
Standard Dome
3.50/1.6
Pendant Cone
2.50/1.1
30° Angle
3.50/1.6
Ceiling
3.00/1.4
Glass Globe
7.00/3.2
Wall
4.00/1.8
Globe Guard
25° Stanchion
3.25/1.5
12” Glass Refractor
90° Stanchion
3.75/1.7
Refractor Guard
Enclosed Reflector
Enclosed Reflector Guard
3.00/1.4
12.00/5.4
4.50/2.0
11.00/5.0
2.00/0.9
* Weights are approximate.
1196
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
Mercmaster™ III Emergency Battery Pack Photometric Data
Enclosed and Gasketed. For Hazardous and Wet Locations
Total Luminaire Efficiency = 58.3%
CIE Type – Semi-Direct
Plane
Spacing
Criteria
2.98
90-270
2.98
Diagonal
2.94
Coefficients of Utilization - Zonal Cavity Method
Effective Floor Cavity Reflectance 0.20
% Ceiling Rcc
% Walls Rw
Lumens
4.21
14.03
29.45
52.29
76.42
97.89
115.41
126.24
130.30
128.10
116.00
87.78
120-130
130-140
140-150
150-160
160-170
170-180
49.16
17.40
3.58
0.35
0.02
0.00
Total Luminaire Efficiency = 77.4%
CIE Type – Direct
Plane
Spacing
Criteria
0-180
1.68
90-270
1.68
Diagonal
1.82
Zone
0-10
10-20
20-30
30-40
40-50
50-60
60-70
70-80
80-90
90-100
100-110
110-120
Lumens
27.68
83.17
138.57
194.85
240.48
264.71
251.68
154.88
37.26
0.55
0.00
0.00
120-130
130-140
140-150
150-160
160-170
170-180
0.00
0.00
0.00
0.00
0.00
0.00
80
70
64
55
48
43
39
36
33
30
28
26
24
0
1
2
3
4
5
6
7
8
9
10
50
64
51
42
36
31
27
24
21
19
17
16
30
64
47
37
30
25
21
18
16
14
12
11
70
10
64
44
33
26
21
17
14
12
10
9
8
70
60
51
45
40
36
33
30
27
25
24
22
50
60
47
39
33
29
25
22
20
18
16
15
30
60
44
34
28
23
20
17
15
13
12
10
50
10
60
41
31
24
19
16
13
11
10
8
7
50
52
40
33
28
24
21
19
17
15
14
13
30
52
38
30
24
20
17
15
13
11
10
9
30
10
52
35
26
21
17
14
11
10
8
7
6
50
45
34
28
24
20
18
16
14
13
12
11
30
45
32
25
20
17
14
12
11
9
8
8
10
10
45
30
22
17
14
11
10
8
7
6
5
50
39
29
23
19
16
14
13
12
10
10
9
30
39
27
21
17
14
12
10
9
8
7
6
0
10
39
25
19
14
11
9
8
7
6
5
4
0
36
23
16
12
9
7
6
5
4
4
3
Zonal Lumen Summary
Zone
0-30
0-40
0-60
0-90
Lumens
47.69
99.98
274.29
646.24
% Lamp
2.6
5.6
15.2
35.9
% Fixture
4.5
9.5
26.2
61.6
Zone
90-120
90-130
90-150
90-180
0-180
Lumens
331.87
381.04
402.02
402.40
1048.64
% Lamp
18.4
21.2
22.3
22.4
58.3
% Fixture
31.6
36.3
36.3
38.4
100.0
REPORT NUMBER: KPBF26BU_ST
26 W (two 13 W PLT lamps) Fluorescent Fixture with Globe and Reflector
Coefficients of Utilization - Zonal Cavity Method
Effective Floor Cavity Reflectance 0.20
% Ceiling Rcc
% Walls Rw
0
1
2
3
4
5
6
7
8
9
10
80
70
92
83
74
66
60
55
50
46
43
40
37
50
92
78
67
57
50
44
39
35
31
29
26
30
92
74
60
50
42
36
31
27
24
22
20
70
10
92
71
55
44
36
30
26
22
19
17
15
70
90
81
72
64
58
53
49
45
41
39
36
50
90
77
65
56
49
43
38
34
31
28
26
30
90
73
59
49
41
35
31
27
24
22
19
50
10
90
70
55
44
36
30
25
22
19
17
15
50
86
73
62
53
46
41
36
33
30
27
25
30
86
70
57
48
40
34
30
26
24
21
19
30
10
86
68
53
43
35
30
25
22
19
17
15
50
82
70
59
51
45
39
35
32
29
26
24
30
82
68
55
46
39
34
29
26
23
21
19
10
10
82
65
52
42
35
29
25
22
19
17
15
50
79
67
57
49
43
38
34
31
28
25
23
30
79
65
54
45
38
33
29
25
23
20
19
0
10
79
63
51
41
34
29
25
21
19
17
15
0
77
62
49
39
32
27
23
20
17
15
13
Zonal Lumen Summary
Zone
0-30
0-40
0-60
0-90
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
Lumens
249.42
444.27
949.47
1393.29
% Lamp
13.9
24.7
52.7
77.4
% Fixture
17.9
31.9
68.1
100.0
Zone
90-120
90-130
90-150
90-180
0-180
Lumens
0.55
0.55
0.55
0.55
1393.83
% Lamp
0.0
0.0
0.0
0.0
77.4
% Fixture
0.1
0.1
0.1
0.1
100.0
1197
Lighting: Enclosed and Gasketed — Emergency
Zone
0-10
10-20
20-30
30-40
40-50
50-60
60-70
70-80
80-90
90-100
100-110
110-120
Lighting
0-180
REPORT NUMBER: KPBF26BU_G
26 W (two 13 W PLT lamps) Fluorescent Fixture with Globe only
Mercmaster™ III Emergency Battery Pack Photometric Data
Enclosed and Gasketed. For Hazardous and Wet Locations
Total Luminaire Efficiency = 90.2%
CIE Type – Semi-Direct
Lighting: Enclosed and Gasketed — Emergency
Lighting
Plane
Spacing
Criteria
0-180
2.72
90-270
2.72
Diagonal
2.72
Zone
0-10
10-20
20-30
30-40
40-50
50-60
60-70
70-80
80-90
90-100
100-110
110-120
Lumens
23.61
79.09
165.61
289.36
418.89
535.78
628.00
682.79
696.63
676.63
612.00
481.82
120-130
130-140
140-150
150-160
160-170
170-180
304.45
133.76
39.22
5.66
0.24
0.00
Total Luminaire Efficiency = 72.8%
CIE Type – Direct
Plane
Spacing
Criteria
0-180
1.66
90-270
1.66
Diagonal
1.80
Zone
0-10
10-20
20-30
30-40
40-50
50-60
60-70
70-80
80-90
90-100
100-110
110-120
Lumens
88.11
264.99
444.26
624.25
769.77
853.68
821.26
573.91
212.45
4.66
0.00
0.00
120-130
130-140
140-150
150-160
160-170
170-180
0.00
0.00
0.00
0.00
0.00
0.00
1198
REPORT NUMBER: KPBF84BU_G
84 W (two 42 W PLT lamps) Fluorescent Fixture with Globe Only
Coefficients of Utilization - Zonal Cavity Method
Effective Floor Cavity Reflectance 0.20
% Ceiling Rcc
% Walls Rw
0
1
2
3
4
5
6
7
8
9
10
80
70
99
85
75
67
61
55
50
46
43
40
37
50
99
78
65
56
48
42
37
33
30
27
25
30
99
73
57
47
39
33
29
25
22
19
17
70
10
99
68
51
40
32
26
22
19
16
14
12
70
93
79
69
62
56
51
46
43
39
37
34
50
93
73
61
52
45
39
35
31
28
25
23
30
93
68
53
44
36
31
27
23
20
18
16
50
10
93
63
47
37
30
25
21
18
15
13
12
50
81
62
52
44
38
33
29
26
24
22
20
30
81
58
46
37
31
26
23
20
17
16
14
30
10
81
55
41
32
26
21
18
15
13
11
10
50
70
53
43
36
31
28
24
22
20
18
17
30
70
50
39
31
26
22
19
17
15
13
12
10
10
70
47
35
27
22
18
15
13
11
9
8
50
60
44
35
30
25
22
20
18
16
15
14
30
60
42
32
26
21
18
15
14
12
11
10
0
10
60
39
29
22
18
14
12
10
9
8
7
0
55
35
25
18
14
11
9
8
7
6
5
Zonal Lumen Summary
Zone
0-30
0-40
0-60
0-90
Lumens
268.3
557.66
1512.33
3519.72
% Lamp
4.2
8.7
23.6
55.0
% Fixture
4.6
9.7
26.2
61.0
Zone
90-120
90-130
90-150
90-180
0-180
Lumens
1770.44
2074.89
2247.86
2253.77
5773.48
% Lamp
27.7
32.4
35.1
35.2
90.2
% Fixture
30.7
35.9
35.9
39.0
100.0
REPORT NUMBER: KPBF84BU_ST
84 W (two 42 W PLT lamps) Fluorescent Fixture with Globe and Reflector
Coefficients of Utilization - Zonal Cavity Method
Effective Floor Cavity Reflectance 0.20
% Ceiling Rcc
% Walls Rw 70
0 87
1 77
2 69
3 62
4 56
5 51
6 47
7 43
8 40
9 37
10 35
80
50 30
87 87
73 69
61 55
53 46
46 38
40 33
36 28
32 25
29 22
26 20
24 18
10
87
65
50
40
33
27
23
20
17
15
14
70
85
75
67
60
54
49
45
42
38
36
34
70
50 30
85 85
71 67
60 55
51 45
45 38
39 32
35 28
31 25
28 22
26 20
24 18
10
85
64
50
40
32
27
23
20
17
15
14
50
81
68
57
49
43
38
34
30
27
25
23
50
30
81
65
53
44
37
31
27
24
21
19
17
10
81
62
49
39
32
27
23
20
17
15
14
50
77
65
55
47
41
36
32
29
26
24
22
30
30
77
62
51
42
36
31
27
24
21
19
17
10
77
60
47
38
31
26
23
20
17
15
14
50
74
62
52
45
39
35
31
28
25
23
22
10
30
74
60
49
41
35
30
26
23
21
19
17
10
74
58
46
37
31
26
22
19
17
15
14
0
0
73
57
45
36
29
24
21
18
15
14
12
Zonal Lumen Summary
Zone
0-30
0-40
0-60
0-90
Lumens
797.37
1421.62
3045.07
4652.69
% Lamp
12.5
22.2
47.6
72.7
% Fixture
17.1
30.5
65.4
99.9
Zone
Lumens
90-120
4.66
90-130
4.66
90-150
4.66
90-180
4.66
0-180 4657.35
% Lamp
0.1
0.1
0.1
0.1
72.8
% Fixture
0.1
0.1
0.1
0.1
100.0
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
Mercmaster™ III Emergency Battery Pack Lumen Curves
Enclosed and Gasketed. For Hazardous and Wet Locations
BHD65U Lumen Curve
One Lamp PL-T 42 W In Emergency Mode
BHD65U Lumen Curve
One Lamp PL-T 32 W In Emergency Mode
400
300
Lighting
350
250
300
250
Lumens
Lumens
200
150
200
100
50
0
50
0
0
10
20
30
40
50
60
70
80
90
80
90
Discharge time (minutes)
0
10
20
30
40
50
60
70
80
90
Discharge time (minutes)
BHD65U Lumen Curve
Two Lamp PL-T 26 W In Emergency Mode
450
400
350
Lumens
300
250
200
150
100
50
0
0
10
20
30
40
50
60
70
Discharge time (minutes)
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
1199
Lighting: Enclosed and Gasketed — Emergency
150
100
N2LS™ Series Emergency Luminaires
Enclosed and Gasketed
Non-Metallic Emergency Lighting Systems with Remote or Direct Mounted Lamps.
Class I, Division 2, Groups B, C, D
Class I, Zone 2, Group IIB + H2
NEMA 3R
Lighting: Enclosed and Gasketed — Emergency
Lighting
Applications
• Enclosed and gasketed, non-metallic emergency lighting
system suitable for use in areas where flammable gases or
vapors may become present due to abnormal, unusual or
accidental conditions defined by NEC as Class I, Division 2,
Groups B, C and D and Class I, Zone 2, Group II B + H2.
• Typical applications include manufacturing plants, refineries,
petrochemical and chemical plants, waste and sewerage
treatment facilities, food processing facilities, and other
industrial manufacturing or process facilities subject to wet or
corrosive conditions.
• Non-hazardous areas where dirt, dust or corrosion would
reduce life of ordinary emergency lighting systems.
Features
• Certified for use in Class I, Division 2, Groups B, C, D; Class I,
Zone 2, Group II B + H2 Hazardous Locations.
• Enclosures are Type 3R (raintight) rated and suited for operation
in highly corrosive and wet locations.
• The electronics consist of a solid-state charger, transfer circuit
and low voltage battery disconnect circuit.
• The test switch and AC “On” indicator light are mounted on the
system housing utilizing a neoprene “O-ring” gasket to seal out
moisture and liquids.
• Capacity is sufficient for the connection of 36 or 72 output
Watts (maximum).
• Housing provisions allow for the attachment of single or dual, 8
or 12 Watt halogen sealed beam heads (Wattage cannot exceed
unit capacity.)
• Provides 90 minutes of emergency operation.
• The solid-state charger maintains battery at full charge.
• Upon failure or 35% dip of utility voltage (AC), the DC
emergency lighting load is connected to the battery.
• During emergency operation, automatic battery protection from
deep discharge damage is provided by a low-voltage battery
disconnect (LVD) circuit.
• Upon restoration of normal power, the charger will begin a
recharge cycle. It will bring the battery to full capacity within
acceptable UL time standards.
• A pilot light indicates the presence of AC line voltage, and a test
switch is provided for checking transfer operation.
• A universal transformer allows operation on 120, 220, 240 or
277 VAC 50/60HZ. lines.
• Emergency power source is a sealed cell, lead acid,
maintenance-free battery suited for harsh temperature
environments of 32° to 104°F / 0° to 40°C.
• 15 amp fuse provided as standard.
• Expected life is 10 years.
• Remote lamp head assemblies (one or two) are available for
mounting of lamp heads away from main power supply system.
• Time delay relay (15 min.) provided as standard; allows time for
HID lighting to reach desired illumination levels.
1200
Standard Materials
• Lighting system:
—Body: Compression molded, fiberglass reinforced polyester
(FRP)
— Gasket: continuous silicone gasket and FRP
— Mounting feet: fiberglass reinforced polyester
• Remote unit:
— Body: specially formulated fiberglass reinforced polyester
with low surface resistivity that will not hold a static charge
— Mounting feet: stainless steel
— Screws (hold covers to bodies): stainless steel
— Gasket (between covers to bodies): neoprene
• Gaskets (under pilot light and push to test switch): neoprene
• Hubs: glass filled polyester with zinc plated steel insert
• Lamphead: Noryl® thermoplastic
Certifications and Compliances
• UL Standard: UL 924
• UL Listed: E175025
• NFPA 101 Life Safety Code
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
N2LS™ Series Emergency Luminaire Technical Data
Enclosed and Gasketed
Non-Metallic Emergency Lighting Systems with Remote or Direct Mounted Lamps.
Class I, Division 2, Groups B, C, D
Class I, Zone 2, Group IIB + H2
NEMA 3R
Order using catalog numbering guide below or select catalog number from tables on following pages.
Catalog Numbering Guide For N2LS
N2LS
2
8
36
Lighting
Lamp Voltage:
6 - 6 Vdc
12 - 12 Vdc
Series:
N2LS - Emergency Lighting System
Wattage Capacity:
36 - 36 W
72 - 72 W
Thermal Performance — Operating Temperatures
Wire Supply
Ambient Temperature
“T” Number
140°F/60°C
Min. 32°F to max 104°F / 0°C to max 40°C
T6
“T” Numbers Represent the Maximum Lamp Temperature for Class I, Division 2 Locations
“T”
Number
T1
350
325
T2
T2A
T2B
T2C
T2D
T3
T3A
T3B
T3C
T4
T4A
T5
T6
Temp.
Range
(˚ºF)
664842
619662
574617
538572
502536
448500
421446
394419
358392
331356
322329
277320
250275
214248
187212
185
Temp
Range
(ºC)
351450
326350
301325
281300
261280
231260
216230
201215
181200
166180
161165
136160
121135
101120
86100
85
Wire Sizing For Remote Installations
For copper wire, maximum distance (feet) between power supply and remote unit to limit voltage drop to 5%.
For 6 Volt Units - Load in Watts
For 12 Volt Units - Load in Watts
Wire Size
8
16
24
32
8
16
24
32
16 AWG
26
13
6
3
52
26
12
6
14 AWG
42
21
10
5
84
42
20
10
12 AWG
66
33
16
8
132
66
32
16
10 AWG
106
53
26
13
212
106
52
26
8 AWG
168
84
42
21
336
168
84
42
6 AWG
270
135
67
33
540
270
134
66
Capacity of Standard N2LS Units
Up to two lamps may be direct mounted. The remainder must be remote mounted.
Number of lamps accommodated is dependent on whether 36 or 72 Watt unit is used.
Combination Number
1
2
3
4
6
7
8
9
10
11
12
13
14
15
Number of Lamps
1
1
2
2
3
3
4
4
5
5
6
7
8
9
Watts per Lamp
8
12
8
12
8
12
8
12
8
12
12
8
8
8
Total Wattage
8
12
16
24
24
36
32
48
40
60
72
56
64
72
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
1201
Lighting: Enclosed and Gasketed — Emergency
Wattage Per Lamp
8-8W
12 - 12 W
N - No Direct Mounted Fixture
Number of Direct Mount Lamps:
0 - None
1 - One
2 - Two
6
N2LS™ Series Emergency Luminaires
Enclosed and Gasketed
Non-Metallic Emergency Lighting Systems with Remote or Direct Mounted Lamps.
Lighting: Enclosed and Gasketed — Emergency
Lighting
Class I, Division 2, Groups B, C, D
Class I, Zone 2, Group IIB + H2
NEMA 3R
Number
Watts
Lamp
Wattage
of Lamps Per Lamp Voltage (DC) Capacity
Emergency Lighting System With Two Direct Mount Lamps
2
8
6
36
2
8
12
36
2
8
6
72
2
8
12
72
2
12
6
36
2
12
12
36
2
12
6
72
2
12
12
72
Hub
Size
Input
Voltage *
Frequency
Weight
lbs/kg
Catalog
Number
3/4”
3/4”
3/4”
3/4”
3/4”
3/4”
3/4”
3/4”
120-277
120-277
120-277
120-277
120-277
120-277
120-277
120-277
50/60 Hz
50/60 Hz
50/60 Hz
50/60 Hz
50/60 Hz
50/60 Hz
50/60 Hz
50/60 Hz
19.50/8.8
19.50/8.8
19.50/8.8
19.50/8.8
19.50/8.8
19.50/8.8
19.50/8.8
19.50/8.8
N2LS28366
N2LS283612
N2LS28726
N2LS287212
N2LS212366
N2LS2123612
N2LS212726
N2LS2127212
36
36
72
72
36
36
72
72
3/4”
3/4”
3/4”
3/4”
3/4”
3/4”
3/4”
3/4”
120-277
120-277
120-277
120-277
120-277
120-277
120-277
120-277
50/60 Hz
50/60 Hz
50/60 Hz
50/60 Hz
50/60 Hz
50/60 Hz
50/60 Hz
50/60 Hz
18.50/8.4
18.50/8.4
18.50/8.4
18.50/8.4
18.50/8.4
18.50/8.4
18.50/8.4
18.50/8.4
N2LS18366
N2LS183612
N2LS18726
N2LS187212
N2LS112366
N2LS1123612
N2LS112726
N2LS1127212
36
36
72
72
3/4”
3/4”
3/4”
3/4”
120-277
120-277
120-277
120-277
50/60 Hz
50/60 Hz
50/60 Hz
50/60 Hz
17.50/7.9
17.50/7.9
17.50/7.9
17.50/7.9
N2LS0N366
N2LS0N3612
N2LS0N726
N2LS0N7212
Catalog
Number
Emergency Lighting System With One Direct Mount Lamp
1
8
6
1
8
12
1
8
6
1
8
12
1
12
6
1
12
12
1
12
6
1
12
12
Emergency Lighting System Without Direct Mount Lamps
—
—
6
—
—
12
—
—
6
—
—
12
Number
of Lamps
Watts
Lamp
Per Lamp Voltage (DC)
Hub
Size
Hub
Position *
Weight
lbs/kg
Remote Mount With One Lamp
8
6
3/4”
Dead End Hub on Right
4.00/1.8
N2RR186
1
8
12
3/4”
Dead End Hub on Right
4.00/1.8
N2RR1812
1
12
6
3/4”
Dead End Hub on Right
4.00/1.8
N2RR1126
1
12
12
3/4”
Dead End Hub on Right
4.00/1.8
N2RR11212
2
8
6
3/4”
Dead End Hub on Right
5.00/2.3
N2RR286
2
8
12
3/4”
Dead End Hub on Right
5.00/2.3
N2RR2812
2
12
6
3/4”
Dead End Hub on Right
5.00/2.3
N2RR2126
2
12
12
3/4”
Dead End Hub on Right
5.00/2.3
N2RR21212
1
Remote Mount With Two Lamps
* Input voltage is 120, 220, 240 and 277
1202
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
N2LS™ Series Emergency Luminaire Dimensions
Enclosed and Gasketed
Non-Metallic Emergency Lighting Systems with Remote or Direct Mounted Lamps.
Dimensions (In/mm)
Direct Mount Fixture
Single Remote Mount Fixture
Dual Remote Mount Fixture
Lighting
1.75"/
44.5 mm
1.00"/
25.4 mm
.31"/
7.9 mm Dia.
(4) mtg holes
7.56"/ 192.0 mm
8.16"/ 207.7 mm
.31"/
7.9 mm Dia.
(4) mtg holes
1.62"/
41.1 mm
.31” dia.
(4) mtg holes
8.78"/ 223.0 mm
9.56"/ 242.8 mm
5.44”/
138.2 mm
Lighting: Enclosed and Gasketed — Emergency
11.63"/296.9 mm
14.80"/375.9 mm
.31"/
7.9 mm Dia.
(4) mtg holes
1.62"/
41.1 mm
2.81"/
71.4 mm
3.50"/
88.9 mm
4.06"/
103.1 mm
12.50"/
317.5 mm
2.81"/
71.4 mm
3.50"/
88.9 mm
4.06"/
103.1 mm
18.61"/
472.7 mm
1.00"/
25.4 mm
12.13"/ 308.1 mm
12.44"/ 316.0 mm
13.25"/ 336.6 mm
14.13"/ 385.9 mm
5.44”/
138.2 mm
1.44”/
35.6 mm
9.63”/
244.6 mm
9.63”/
244.6 mm
6.88”/
174.8 mm
1.38"/
35.1 mm
4.65"/
118.1 mm
1.38"/
35.1 mm
4.65"/
118.1 mm
Adjustment Angle Data For Remote Unit
100º
55º
26º
Top View
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
Side View
1203
N2LS™ Series Emergency Luminaire Photometric Data
Enclosed and Gasketed
Non-Metallic Emergency Lighting Systems with Remote or Direct Mounted Lamps.
Lighting
Photometric Data
Horizontal Isofootcandle Distribution Curves for 8 Watts
Vertical Isofootcandle Distribution Curves for 8 Watts
20
20
20
20
Feet
Feet
Left
Left
Feet
Feet
Left
Left
10
10
10
10
Lamp
Axis
Lighting: Enclosed and Gasketed — Emergency
00
1
0.5
0.3
0.2
20
20
00
10
10
20
20
30
30
40
40
50
50
FEET FROM LAMP ( MEASURED ON AXIS )
60
60
70
70
80
80
0.2
0.1
00
10
10
20
20
30
40
50
30
40
50
FEET FROM LAMP ( MEASURED ON AXIS )
60
60
70
70
80
80
FEET FROM LAMP (MEASURED ON AXIS)
Vertical Isofootcandle Distribution Curves for 12 Watts
Horizontal Isofootcandle Distribution Curves for 12 Watts
20
20
Feet
Feet
Left
Left
10
10
20
20
Feet
Feet
Left
Left
10
10
1
00
00
20
20
0.5
40
40
0.3
0.2
60
60
FEET
FEETFROM
FROMLAMP
LAMP( MEASURED
(MEASUREDON
ONAXIS
AXIS))
1204
0.3
Feet
Feet
Right
Right
FEET FROM LAMP (MEASURED ON AXIS)
10
10
Feet
Feet
Left
Left
20
20
0.5
10
10
10
10
Feet
Feet
Right
Right
20
20
1
Lamp
Axis
00
0.1
0.1
80
80
1
0
100
100
10
10
Feet
Feet
Left
Left
20
20
00
20
20
0.5
40
40
0.3
0.2
60
60
0.1
80
80
100
100
FEET FROM LAMP ( MEASURED ON AXIS )
FEET FROM LAMP (MEASURED ON AXIS)
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
Code•Master Jr.™ HID Factory Sealed Luminaires
Explosionproof, Dust-Ignitionproof
Integrally Ballasted. 50 W, 70 W, 100 W, 150 W HPS; 50 W, 70 W, 100 W, 175 W PSMH. 175 W MH V. Medium Base. For Use with Threaded Metal Conduit.
NEC:
Class I, Division 1 and 2, Groups B, C, D
Class II, Division 1 and 2, Groups E, F, G
Class III
Marine type electric fixtures, outside type
(salt water)
CSA: V
Class I, Division 1 and 2, Groups B, C, D
Class II, Division 1 and 2, Groups E, F, G
Class III
Type 4X
Exd IIB + H2
Applications
• For use in chemical and petrochemical plants, such as
manufacturers of plastics, paints and thinners; in refineries;
and in other areas where ignitable vapors, dust, moisture
and corrosive elements may be present.
• Suitable for outdoor saltwater locations and for other
wet locations.
Features
Lighting
Standard Materials
• Ballast bodies and guards: copperfree (4/10 of 1% max.)
aluminum
• Pendant mounting hoods: diecast copperfree (4/10 of 1% max.)
aluminum
• Ceiling, bracket and stanchion mounting hoods: sand cast
copperfree (4/10 of 1% max.) aluminum
• Reflectors: fiberglass reinforced polyester
Standard Finishes
• Ballast bodies, guards and mounting hoods: epoxy powder
coat finish, electrostatically applied for complete, uniform
corrosion protection
Options
• Fuses: order fuses for field installation by catalog number, see
Ballast and Fuse Kit Data.
• “Hot Restrike” – add suffix -R. “Smart Starter” – add suffix -S.
Emergency Options available for 50 W through 150 W HPS only.
• For CEC Exd IIB + H2 rating, add suffix -Z V.
• For safety chain, add suffix -SC.
Certifications and Compliances
•
•
•
•
UL Standard: UL 1598, UL 844
UL Listed: E10444
CSA Standard: C22.2 No. 250, C22. 2No. 137
CSA Certified: 025428
Related Products
• For sealing fittings, see the Fittings Section.
V CSA Certification only.
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
1205
Lighting: Explosionproof — Area — HID
• Fixtures operate safely in high ambient temperatures.
• Arrangement of heat-producing components results in
efficient heat dissipation for cooler fixture operation.
• Patented “wireless” design. Threading of fixture unit
onto mounting hood makes electrical connection. Only
wiring required is attaching two wires to connection block
in mounting hood.
• Connection block is easily wired: (a) loosen two screws, (b)
make wire connections, and (c) re-position connection block.
• Safe, easy servicing without disconnecting any wiring.
“Wireless” fixture unit threads off mounting hood for convenient
servicing or for immediate replacement with a “stand-by” unit.
• Acme double-lead threads speed installation and fixture
removal from mounting hood – only half as many turns are
required as for single-lead threads. The threads do not stick or
gall, eliminating problems often encountered with single-lead
threads during fixture unit removal.
• All threaded joints are flame-tight.
• Integrally ballasted HID lighting fixtures; separate ballasts
not required.
• Factory sealed. External seals not required for Groups C and D.
• Fixtures for use in NEC Group B locations furnished complete
with UL required sealing fitting. Not required for CEC approval.
• Strategic location of lamp socket, in combination with interior
prism design of the glass globe, provides optimum light
distribution and control.
• Heat and impact-resistant globes have smooth
dust-resistant exterior.
• Superior corrosion resistance, with epoxy powder coat finish.
• Shock-absorbing medium-base socket mounts prolong
lamp life.
• Porcelain socket with nickel-plated phosphor bronze
screw shell.
Assures long trouble-free operation in high ambient areas.
• Choice of mountings: pendant, ceiling, bracket and stanchion.
• Fiberglass-reinforced polyester reflectors, in standard dome,
or 30° angle styles, are ideal in installations where luminaire is
subject to exceptionally severe corrosive atmospheres.
• Optional guards protect globes from damage. Secured to
fixture with three stainless steel screws.
• Variety of light sources: high pressure sodium, pulse start metal
halide and metal halide. HPS is excellent where long lamp life
is required. HPS provides high lumens per watt and is less
expensive to operate. PSMH and MH are desirable where
colors in illuminated areas must be close to natural.
• A wide range of ballasts and voltages are available for both
domestic and export applications.
• Ballasts operate at low temperatures – PSMH/MH: -20 °F/-29 °C;
HPS: -40 °F/-40 °C.
• 50 W through 150 W high pressure sodium ballasts are high
reactance, high power factor type.
Code•Master Jr.™ HID Factory Sealed Luminaires
Explosionproof, Dust-Ignitionproof
Integrally Ballasted. 50 W, 70 W, 100 W, 150 W HPS; 50 W, 70 W, 100 W, 175 W PSMH. 175 W MH V. Medium Base. For Use with Threaded Metal Conduit.
NEC:
Class I, Division 1 and 2, Groups B, C, D
Class II, Division 1 and 2, Groups E, F, G
Class III
Marine type electric fixtures, outside type
(salt water)
CSA: V
Class I, Division 1 and 2, Groups B, C, D
Class II, Division 1 and 2, Groups E, F, G
Class III
Type 4X
Exd IIB + H2
104 °F/40˚ °C ➊
Lamp
Watts
Ambient
Temp. “T”
Numbers
Ballast
Type †
Supply
Wire Temp
°F/°C
131 °F/55 ˚°C ➊
149 °F/65 °C ➊
104 °F/40 ˚°C ➋
Ambient
Temp. “T”
Numbers
Supply
Wire Temp
°F/°C
Ambient
Temp. “T”
Numbers
Supply
Wire Temp
°F/°C
Ambient
Temp. “T”
Numbers
Supply
Wire Temp
°F/°C
High Pressure Sodium — Medium Base Lamps
50
MT, TT
T6
167/75
T5
167/75
T4A
167/75
T4
167/75
70
MT, TT, 480 V
T5
167/75
T4A
167/75
T4A
167/75
T4
194/90
100
MT, TT, 480 V
T4A
167/75
T4
194/90
—
T3B
194/90
150
MT, TT, 480 V
T3C
167/75
—
—
—
T6
167/75
T5
167/75
T4A
194/90
T3C
194/90
194/90
T3C
194/90
Lighting
Pulse Start Metal Halide — Medium Base Lamps
50
MT, TT
70
MT, TT, 480 V
T5
167/75
T4A
167/75
T4A
100
MT, TT, 480 V
T4A
194/90
T4A
194/90
—
175
MT, TT, 480 V
T3B
194/90
—
—
—
T3B
185/85
—
—
—
Metal Halide — Medium Base Lamps V
Lighting: Explosionproof — Area — HID
175
MT, TT, 480 V
“T” Numbers Represent the Maximum Surface Temperature for Class I, Division 1 Locations and
Maximum Surface Temperature Under Dust Blanket for Class II, Division 1 Locations.
“T”
Number
T1
350
325
T2
T2A
T2B
T2C
T2D
T3
T3A
T3B
T3C
T4
T4A
T5
T6
Temp.
Range
(°F)
664842
619662
574617
538572
502536
448500
421446
394419
358392
331356
322329
277320
250275
214248
187212
185
Temp.
Range
(°C)
351450
326350
301325
281300
261280
231260
216230
201215
181200
166180
161165
136160
121135
101120
86100
85
Fixture and Accessory Weights lbs/kgs
Fixture Size
Fixture Weight
Reflector Weight
Guard Weight
35 W thru 175 W
28-32/12.70-14.51
3/1.36
1/0.45
Pendant
Ceiling
Bracket
Stanchion
2/.91
4/1.81
6/2.72
2/0.91
Mounting Hood Weights lbs/kgs
NOTE: The maximum operating temperature of the fixture must not exceed the ignition temperature of the gas, vapor or dust to be encountered per the National
Electrical Code and the Canadian Electrical Code.
† MT is Multi-Tap for 120/208/240/277 V, TT is Tri-Tap for 120/277/347 V.
➊ Class I, Division 1 Locations.
➋ Class II, Division 1 Locations.
V CSA Certification only.
1206
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
Code•Master Jr.™ HID Factory Sealed Luminaires
Explosionproof, Dust-Ignitionproof
Integrally Ballasted. 50 W, 70 W, 100 W, 150 W HPS; 50 W, 70 W, 100 W, 175 W PSMH. 175 W MH V. Medium Base. For Use with Threaded Metal Conduit.
NEC:
Class I, Division 1 and 2, Groups B, C, D
Class II, Division 1 and 2, Groups E, F, G
Class III
Marine type electric fixtures, outside type
(salt water)
Type
Mounting
Lamp
Watts
ANSI Lamp Type ➎
HPS
Catalog Number➌ ➋
PSMH
Hub Size
(Inches)
HPS➋ ➊
PSMH
M110
3/4
CJLPB5075 ➌
CJHPB5075 ➌
M98
3/4
CJLPB7075 ➍
CJHPB7075 ➍
M90
3/4
CJLPB1075 ➍
CJHPB1075 ➍
—
3/4
CJLPB1575 ➍
—
M152
3/4
—
CJPPB1775 ➍
M110
1-1/2
CJLSB50150 ➌
CJHSB50150 ➌
M98
1-1/2
CJLSB70150 ➍
CJHSB70150 ➍
M90
1-1/2
CJLSB10150 ➍
CJHSB10150 ➍
—
1-1/2
CJLSB15150 ➍
—
M152
1-1/2
—
CJPSB17150 ➍
Pendant - One Hub, Rigid or Flexible Mounting
S68
70
S62
100
S54
150
S55
175
—
Lighting
50
25˚ Stanchion - One Hub
50
100
150
175
S62
S54
S55
—
Mounting Hoods
Type
Mounting
Hub Size
(Inches)
Catalog
Number
Pendant
One Hub
3/4
CAP-75B
One Hub
1-1/2
CAS-150B
25˚ Stanchion
➊ Add suffix -SR (after adding voltage suffix) for “Smart Hot Strike” emergency option, -R for “Hot Restrike” and -S for “Smart Starter” options.
➋ To order fixture with guard, add suffix -G (before adding voltage suffix).
➌ Add voltage -MT for 120/208/240/277 V. For 480 V, contact your sales representative.
➍ Add voltage suffix -MT for 120/208/240/277 V, or -48 for 480 V. Contact your sales representative for available 50 Hz ballasts.
➎ Refer to lamp manufacturer’s data regarding lamp burning position restrictions.
➏ 35 W fixtures have 120 V ballast; add suffix -12
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
1207
Lighting: Explosionproof — Area — HID
70
S68
Code•Master Jr.™ HID Factory Sealed Luminaires
Explosionproof, Dust-Ignitionproof
Integrally Ballasted. 50 W, 70 W, 100 W, 150 W HPS; 50 W, 70 W, 100 W, 175 W PSMH. 175 W MH V. Medium Base. For Use with Threaded Metal Conduit.
NEC:
Class I, Division 1 and 2, Groups C, D
Class II, Division 1 and 2, Groups E, F, G
Class III
Marine type electric fixtures, outside type
(salt water)
CSA: V
Class I, Division 1 and 2, Groups B, C, D
Class II, Division 1 and 2, Groups E, F, G
Class III
Type 4X
Exd IIB + H2
ANSI Lamp Type ➏
Lamp
Watts
HPS
PSMH/MH
Pendant — One Hub, Rigid or Flexible Mounting
Hub Size ➐
(Inches)
3/4
50
S68
M110
1
3/4
70
S62
M98
1
3/4
Lighting
100
S54
M90
1
3/4
150
S55
—
Lighting: Explosionproof — Area — HID
1
3/4
175
—
M152
1
Catalog Number ➋
HPS ➊
50
S68
M110
1
3/4
70
S62
M98
1
3/4
100
S54
M90
1
3/4
150
S55
—
1
3/4
175
—
M152
1
MH
CJLP5075MT ➌
CJLP5075TTCN V ➌
CJLP5010MT ➌
CJLP5010TTCN V ➌
CJLP7075MT ➍
CJLP7075TTCN V➎
CJLP7010MT ➍
CJLP7010TTCN V➎
CJLP1075MT ➍
CJLP1075TTCN V➎
CJLP1010MT ➍
CJLP1010TTCN V➍
CJLP1575MT ➍
CJLP1575TTCN V➎
CJLP1510MT ➍
CJLP1510TTCN V➍
—
—
—
—
—
CJHP5075MT ➌
—
CJHP5075TTCN V ➌
—
CJHP5010MT ➌
—
CJHP5010TTCN V ➌
—
CJHP7075MT ➍
—
CJHP7075TTCN V➎
—
CJHP7010MT ➍
—
CJHP7010TTCN V➎
—
CJHP1075MT ➍
—
CJHP1075TTCN V➎
—
CJHP1010MT ➍
—
CJHP1010TTCN V➎
—
—
—
—
—
—
—
—
CJPP1775MT ➍
CJHP1775MTCN V ➍
CJPP1775TTCN V➎ CJHP1775TTCN V➎
CJPP1710MT ➍
CJHP1710MTCN V➍
CJPP1710TTCN V➎ CJHP1710TTCN V➎
CJLC5075MT ➌
CJLC5075TTCN V➌
CJLC5010MT ➌
CJLC5010TTCN V➌
CJLC7075MT ➍
CJLC7075TTCN V➎
CJLC7010MT ➍
CJLC7010TTCN V➎
CJLC1075MT ➍
CJLC1075TTCN V➎
CJLC1010MT ➍
CJLC1010TTCN V➎
CJLC1575MT ➍
CJLC1575TTCN V➎
CJLC1510MT ➍
CJLC1510TTCN V➎
—
—
—
—
—
CJHC5075MT ➌
—
CJHC5075TTCN V➌
—
CJHC5010MT ➌
—
CJHC5010TTCN V➌
—
CJHC7075MT ➍
—
CJHC7075TTCN V➎
—
CJHC7010MT ➍
—
CJHC7010TTCN V➎
—
CJHC1075MT ➍
—
CJHC1075TTCN V➎
—
CJHC1010MT ➍
—
CJHC1010TTCN V➎
—
—
—
—
—
—
—
—
CJPC1775MT ➍
CJHC1775MTCN V➍
CJPC1775TTCN V➎ CJHC1775TTCN V➎
CJPC1710MT ➍
CJHC1710MTCN V➍
CJPC1710TTCN V➎ CJHC1710TTCN V➎
Ceiling — Four Hubs, Three Close-Up Plugs
3/4
PSMH
➊ Add suffix -R for “Hot Restrike” and -S for “Smart Starter” options.
➋ To order fixture with guard, add suffix -G before adding voltage suffix.
➌ For 480 V, contact your sales representative.
➍ Change voltage suffix -MT to -48 for 480 V.
➎ Change voltage suffix -TT (120/277/347 V) to -MT for 120/208/240/277 V, -C2 for 208 V, -C3 for 240 V, -C6 for 480 V, or -C7 for 600 V, V
➏ Refer to lamp manufacturer’s data regarding lamp burning position restrictions.
➐ Fixtures with 1” hubs listed for Class I, Group D, and Class II, Groups E, F, G only.
V CSA Certification only.
Shaded area indicates items suitable for Class I, Division 1, Group B. V
1208
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
Code•Master Jr.™ HID Factory Sealed Luminaires
Explosionproof, Dust-Ignitionproof
Integrally Ballasted. 50 W, 70 W, 100 W, 150 W HPS; 50 W, 70 W, 100 W, 175 W PSMH. 175 W MH V. Medium Base. For Use with Threaded Metal Conduit.
NEC:
Class I, Division 1 and 2, Groups C, D
Class II, Division 1 and 2, Groups E, F, G
Class III
Marine type electric fixtures, outside type
(salt water)
CSA: V
Class I, Division 1 and 2, Groups B, C, D
Class II, Division 1 and 2, Groups E, F, G
Class III
Type 4X
Exd IIB + H2
Lamp ANSI Lamp Type ➏
Watts HPS PSMH/MH
Bracket — Four Hubs, Three Close-Up Plugs
Hub Size ➐
(Inches)
3/4
50
S68
M110
1
3/4
70
S62
M98
1
3/4
100
S54
M90
3/4
150
S55
—
1
175
—
M152
1
25˚ Stanchion — One Hub
50
S68
M110
70
S62
M98
100
S54
M90
150
S55
—
175
—
M152
1-1/4 or 1-1/2 CJLS50150MT ➌
➑
CJLS50150TTCN V➌
1-1/4 or 1-1/2 CJLS70150MT ➍
➑
CJLS70150TTCN V➍
1-1/4 or 1-1/2 CJLS10150MT ➍
➑
CJLS10150TTCN V➍
1-1/4 or 1-1/2 CJLS15150MT ➍
➑
CJLS15150TTCN V➍
—
1-1/4 or 1-1/2
➑
—
CJHB5075MT ➌
CJHB5075TTCN V➌
CJHB5010MT ➌
CJHB5010TTCN V➌
CJHB7075MT ➍
CJHB7075TTCN V➎
CJHB7010MT ➍
CJHB7010TTCN V➎
CJHB1075MT ➍
CJHB1075TTCN V➎
CJHB1010MT ➍
CJHB1010TTCN V➎
—
—
—
—
CJPB1775MT ➍
CJPB1775TTCN V➎
CJPB1710MT ➍
CJPB1710TTCN V➎
MH
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
CJHB1775MTCN V➍
CJHB1775TTCN V➎
CJHB1710MTCN V➍
CJHB1710TTCN V➎
—
CJHS50150MT ➌
—
CJHS50150TTCN V➌
—
CJHS70150MT ➌
—
CJHS70150TTCN V➌
—
CJHS10150MT ➌
—
CJHS10150TTCN V➌
—
—
—
—
CJPS17150MT
CJHS17150MTCN V
CJPS17150TTCN V
CJHS17150TTCN V
➊ Add suffix -R for “Hot Restrike” and -S for “Smart Starter” options.
➋ To order fixture with guard, add suffix -G before adding voltage suffix.
➌ For 480 V, contact your sales representative.
➍ Change voltage suffix -MT to -48 for 480 V.
➎ Change voltage suffix -TT (120/277/347 V) to -MT for 120/208/240/277 V, -C2 for 208 V, -C3 for 240 V, -C6 for 480 V, or -C7 for 600 V, V
➏ Refer to lamp manufacturer’s data regarding lamp burning position restrictions.
➐ Fixtures with 1” hubs listed for Class I, Group D, and Class II, Groups E, F, G only.
➑ 1-1/2" tapped hub furnished with 1-1/2" to 1-1/4" reducer.
V CSA Certification only.
Shaded area indicates items suitable for Class I, Division 1, Group B. V
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
1209
Lighting: Explosionproof — Area — HID
3/4
CJLB5075MT ➌
CJLB5075TTCN V➌
CJLB5010MT ➌
CJLB5010TTCN V➌
CJLB7075MT ➍
CJLB7075TTCN V➎
CJLB7010MT ➍
CJLB7010TTCN V➎
CJLB1075MT ➍
CJLB1075TTCN V➎
CJLB1010MT ➍
CJLB1010TTCN V➎
CJLB1575MT ➍
CJLB1575TTCN V➎
CJLB1510MT ➍
CJLB1510TTCN V➎
—
—
—
—
Catalog Number ➋
PSMH
Lighting
1
HPS ➊
Code•Master Jr.™ HID Factory Sealed Luminaire Mounting Hoods and Fixture Units
Explosionproof, Dust-Ignitionproof
Integrally Ballasted. 50 W, 70 W, 100 W, 150 W HPS; 50 W, 70 W, 100 W, 175 W PSMH. 175 W MH V. Medium Base. For Use with Threaded Metal Conduit.
NEC:
Class I, Division 1 and 2, Groups B,C, D
Class II, Division 1 and 2, Groups E, F, G
Class III
Marine type electric fixtures, outside type
(salt water)
CSA: V
Class I, Division 1 and 2, Groups B, C, D
Class II, Division 1 and 2, Groups E, F, G
Class III
Type 4X
Exd IIB + H2
Mounting Hoods
Hub Size (Inches)
Catalog Number
Pendant — One Hub
3/4
CAP-75
1➋
CAP-100
Ceiling — Four Hubs, Three Close-Up Plugs
3/4
CAC-75
1➋
CAC-100
3/4
CALB-75
1➋
CALB-100
Lighting
Bracket — Four Hubs, Three Close-Up Plugs
25˚ Stanchion — One Hub
CAS-150
Lighting: Explosionproof — Area — HID
1-1/4 or 1-1/2 ➊
Mounting Adapter with Connection Block
Permits use of existing A-51 mounting hoods (AAC Ceiling
or AALB Bracket) with the new Code•Master 2 Fixture Unit.
After removing existing fixture unit and adapter, screw in
the new CMAD-1 Adapter. Then thread new fixture unit into
the CMAD-1.
CMAD-1
Fixture Units
Ballast body with globe. Indicate voltage desired by adding voltage suffix to fixture unit catalog number listed below.
Type
Lamp
Watts
50
High Pressure Sodium ➌
High Power Factor
(Min. P.F. 90%)
Pulse Start Metal Halide
Constant Wattage
(Min. P.F. 90%)
Metal Halide V
Constant Wattage
(Min. P.F. 90%)
Fixture Unit
Number
CJB50L-
120/208/240/277
MT
Add Voltage Suffixes
120/277/347 V➍
TTCN
480 V
—
70
CJB70L-
MT
TTCN
48
100
CJB100L-
MT
TTCN
48
150
CJB150L-
MT
TTCN
48
50
CJB50H-
MT
TTCN
—
70
CJB70H-
MT
TTCN
48
100
CJB100H-
MT
TTCN
48
175
CJB175P-
MT
TTCN
48
175
CJB175H-
MT
TT
C6
➊ 1-1/2” Tapped hub furnished with 1-1/2” to 1-1/4” reducer.
➋ Mounting Hoods with 1” hub listed for Class I, Group D; Class II, Groups E,F,G; and Class III only.
➌ Add suffix -R for “Hot Restrike” and -S for “Smart Starter” options.
➍ Change voltage suffix -TTCN to -MTCN for 120/208/240/277 V, -C2 for 208 V, -C3 for 240 V, -C6 for 480 V, or -C7 for 600 V, V
V CSA Certification only.
Shaded area indicates items suitable for Class I, Division 1, Group B.
1210
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
Code•Master Jr.™ HID Factory Sealed Luminaire Accessories
Explosionproof, Dust-Ignitionproof
Integrally Ballasted. 50 W, 70 W, 100 W, 150 W HPS; 50 W, 70 W, 100 W, 175 W PSMH. 175 W MH V. Medium Base. For Use with Threaded Metal Conduit.
Description
Catalog Number
Polyester Reflectors
Furnished with stainless steel screws
Standard Dome
Standard Dome
KR2-ST
30° Angle
KR2-AN
Epoxy enameled steel — 6”-high red lettering
CJEXRN
30° Angle
Three-Way Exit Sign
Mounts to Code•Master Jr. fixture units in place of guard.
Lighting
Single Sided Exit Sign
Epoxy enameled steel — 6”-high red lettering
AEXR-15R
Mounts to Code•Master Jr. fixture units in place of guard.
*Contact your sales representative regarding hazardous location suitability.
CJGL-175
Aluminum Guards — 50 W through 175 W
CJGU-15
Replacement Sockets — 50 W through 175 W
Connection Block — 50 W through 175 W
Medium base sockets
CJMS-175
For all Code•Master fixtures
VPT-7
HPS Hot Restrike
Restrikes HPS lamp immediately when power is restored after a momentary power interruption.
Optional for fixture watts of 50, 70, 100 or 150 (HPS only)
Add suffix -R
Smart Starter
Smart Starter is for HPS fixtures only. Incorporates a 1-1/2-minute timer and performs as a conventional starter to normally start lamp.
Removes itself from circuit if lamp burns out or is removed from socket. Eliminates starter failures caused by prolonged operation with
cycling or failing lamps and simplifies finding their location which reduces maintenance and repair costs.
Optional for all HPS and PSMH fixtures.
Add suffix -S
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
1211
Lighting: Explosionproof — Area — HID
Prismatic Glass Globe and Ring Assembly — 50 W through 175 W
Code•Master Jr.™ HID Factory Sealed Luminaire Ballast and Fuse Kit Data
Explosionproof, Dust-Ignitionproof
Integrally Ballasted. 50 W, 70 W, 100 W, 150 W HPS; 50 W, 70 W, 100 W, 175 W PSMH. 175 W MH V. Medium Base. For Use with Threaded Metal Conduit.
NEC:
Class I, Division 1 and 2, Groups B, C, D
Class II, Division 1 and 2, Groups E, F, G
Class III
Marine type electric fixtures, outside type
(salt water)
Volts
Ballast Amps
High Pressure Sodium
Pulse Start Metal Halide
HX-H.P.F. ➊
HX-H.P.F. ➊ — Super CWA ➋
Start
Operating
Start
Operating
HPS
PSMH
MH V
120
0.58
0.58
0.87
0.60
1
CF-5
CF-3
—
208
0.35
0.33
0.51
0.40
2
CF-3
CF-3
—
240
0.31
0.29
0.47
0.35
2
CF-3
CF-2
—
277
0.25
0.25
0.32
0.32
1
CF-2
CF-2
—
347 V
—
—
—
—
—
—
—
—
Lamp
Watts
Lighting
50
Lighting: Explosionproof — Area — HID
70
100
150
175
CSA: V
Class I, Division 1 and 2, Groups B, C, D
Class II, Division 1 and 2, Groups E, F, G
Class III
Type 4X
Exd IIB + H2
Fuse Kit Catalog Number
Fuse
Quantity
Required
480
—
—
—
—
—
—
—
—
120
0.90
0.82
0.80
0.85
1
CF-5
CF-5
—
208
0.50
0.48
0.50
0.52
2
CF-3
CF-3
—
240
0.44
0.41
0.43
0.44
2
CF-3
CF-3
—
277
0.35
0.36
0.39
0.39
1
CF-2
CF-2
—
347 V
0.30
0.30
0.20
0.28
1
CF-2
CF-2
—
480
0.21
0.21
0.26
0.23
2
CF-2
CF-2
—
120
1.30
1.15
1.20
1.15
1
CF-8
CF-8
—
208
0.76
0.67
0.70
0.70
2
CF-5
CF-5
—
240
0.66
0.58
0.61
0.58
2
CF-5
CF-3
—
277
0.60
0.50
0.55
0.50
1
CF-3
CF-3
—
347 V
0.45
0.30
0.40
0.40
1
CF-2
CF-2
—
480
0.33
0.31
0.30
0.35
2
CF-3
CF-2
—
120
2.00
1.66
—
—
1
CF-10
—
—
208
1.16
0.96
—
—
2
CF-5
—
—
240
1.00
0.83
0.85
0.80
2
CF-5
CF-5
—
277
1.00
0.83
—
—
1
CF-5
—
—
—
347 V
0.52
0.56
0.55
0.65
1
CF-3
—
480
0.88
0.75
—
—
2
CF-5
—
—
120
1.30
1.80
0.90
1.78
1
—
CF-5
CF-5
208
0.75
1.04
0.50
1.08
2
—
CF-3
CF-3
240
0.65
0.90
0.35
0.89
2
—
CF-3
CF-3
277
0.55
0.80
0.30
0.76
1
—
CF-2
CF-2
347 V
0.27
0.65
0.25
0.65
1
—
CF-2
CF-2
480
0.35
0.45
0.25
0.50
2
—
CF-2
CF-2
Fuse Kit includes fuse, fuse holder and necessary hardware for field installation. Mounts easily in ballast body with one screw. Order one fuse for 120 V and 277
V, and 2 fuses for 208, 240 and 480 V. CF-2 = 2 Amp; CF-3 = 3 Amp; CF-5 = 5 Amp; CF-8 = 8 Amp; CF-10 = 10 Amp
➊ 35 W through 150 W HPS and 50 W through 100 W PSMH have H.P.F. High Reactance ballasts.
➋ 175 W PSMH 480 volts has CWA ballast. Multi-tap has Super CWA ballast.
V CSA Certification only.
1212
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
Code•Master Jr.™ HID Factory Sealed Luminaire Dimensions
Explosionproof, Dust-Ignitionproof
Integrally Ballasted. 50 W, 70 W, 100 W, 150 W HPS; 50 W, 70 W, 100 W, 175 W PSMH. 175 W MH V. Medium Base. For Use with Threaded Metal Conduit.
Pendant
Ceiling
Bracket
0.41"/
10.4 mm Dia.
2.46"/
2.28"/
62.5 mm 57.9 mm
4.25"/
108.0 mm
4.58"/
116.3 mm Dia.
3.75"/95.3 mm
4.92"/
125.0 mm Sq.
4.00"/
101.6 mm
4.50"/
114.3 mm
17.22"/
437.4 mm
4.00"/
101.6 mm
7.40"/
188.0 mm
17.87"/
453.9 mm
1.23"/
31.2 mm
3.46"/
87.9 mm
3.92"/
99.6 mm
5.92"/
150.4 mm
1.79"/
45.5 mm
11.5"/
292.1 mm
13.75"/
349.3 mm
14.12"/
358.6 mm
Lighting
7.40"/
188.0 mm
17.47"/
443.7 mm
18.12"/
460.2 mm
7.40"/
188.0 mm
8.00"/
203.2 mm
25˚ Stanchion
16.00"/
406.4 mm
Exit Signs
9.5"/
241.3 mm
6.10"/
154.9 mm
Reflectors
8.00"/
203.2 mm
6.88"/
174.8 mm
2.75"/
69.9 mm
11.75"/298.5 mm
4.5"/
60.5 mm Dia.
2.38"/
60.5 mm Dia.
16.25"/
412.8 mm
Lighting: Explosionproof — Area — HID
14.12"/
358.6 mm
15.62"/
396.7 mm
8.50"/
215.9 mm
14.9"/
378.5 mm
10.17"/
258.3 mm
8.00"/
203.2 mm
1.5 - 11 NPT
AEXR-15R
30° Angle
8.00"/
203.2 mm
6.00"/
152.4 mm
16.88"/
428.8 mm
16.00"/
406.4 mm
9.25"/
235.0 mm
12.00"/
304.8 mm
16.9"/
429.3 mm
CJEXRN
Standard Dome
16.25"/
412.8 mm
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
1213
Code•Master Jr.™ HID Factory Sealed Luminaire HPS Photometric Data
Explosionproof, Dust-Ignitionproof
Integrally Ballasted. 50 W, 70 W, 100 W, 150 W HPS; 50 W, 70 W, 100 W, 175 W PSMH. 175 W MH V. Medium Base. For Use with Threaded Metal Conduit.
* Photometric data is based on a fixture with
a 150-watt clear High Pressure Sodium lamp
(16,000 lumen), without guard. For candlepower
values of fixtures with other HPS lamps, use
the following multipliers:
for a 100 W (9,500 lumen) HPS lamp – 0.594; for
Lighting
Zone
Lumens
Total Luminaire Efficiency = 77.5%
0-10
10-20
20-30
32.97
119.16
313.87
CIE Type - General Diffuse
30-40
349.57
40-50
804.55
50-60
1193.29
% Ceiling Rcc
60-70
1327.33
% Walls
70-80
1576.23
Zonal Lumen Summary
80-90
90-100
100-110
110-120
120-130
130-140
140-150
150-160
160-170
170-180
1672.01
1647.69
1507.22
1221.25
607.81
27.17
1.62
0.35
0.07
0.02
Zone
Lumens % Lamp % Fixture
0-30
465.99
2.9
3.8
0-40
815.56
5.1
6.6
0-60
2813.41
17.6
22.7
0-90
7388.98
46.2
59.6
90-120 4376.17
27.4
35.3
90-130 4983.97
31.1
40.2
90-150 5012.76
31.3
40.2
90-180 5013.20
31.3
40.4
180-0 12402.18
77.5
100.0
Zone
Lumens
Total Luminaire Efficiency = 66.9%
249.34
CIE Type - Direct
0-10
Lighting: Explosionproof — Area — HID
a 70 W (6,400 lumen) HPS lamp – 0.394;
for a 70 W (5800 lumen) HPS lamp – 0.363;
for a 50 W (4,000 lumen) HPS lamp – 0.25;
for a 35 W (2,250 lumen) HPS lamp – 0.141.
For candlepower values of fixture with guard,
multiply by 0.95.
Coefficients of Utilization - Zonal Cavity Method
Effective Floor Cavity Reflectance 0.20
10-20
810.25
20-30
1450.35
30-40
1495.68
0-180
1.44
40-50
1920.69
90-270
1.44
50-60
2259.61
Diagonal
1.80
60-70
1846.14
70-80
541.69
80-90
90-100
100-110
110-120
120-130
130-140
140-150
150-160
160-170
170-180
125.07
0.70
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
Zone
Lumens
0-10
58.31
Spacing
Criteria
Plane
Total Luminaire Efficiency = 61.8%
10-20
482.43
904.49
30-40
1163.85
0-180
2.08
40-50
1479.08
90-270
1.38
50-60
1630.56
Diagonal
1.54
60-70
1467.51
70-80
1258.91
1214
Plane
Spacing
Criteria
Zonal Lumen Summary
Lumens % Lamp % Fixture
1445.23
9.0
14.6
2609.08 16.3
26.4
5718.73 35.7
57.8
9522.24 59.5
96.3
361.80
2.3
3.7
370.13
2.3
3.7
370.23
2.3
3.7
370.23
2.3
3.7
9892.48 61.8
100.0
30
10
0
72
64
57
51
46
42
39
36
33
31
66
55
47
40
35
31
28
25
23
21
61
48
39
32
27
23
20
18
16
14
57
42
33
26
21
18
15
13
11
10
67
58
52
47
42
39
36
33
31
29
61
51
43
37
32
29
26
23
21
19
57
44
36
30
25
22
19
17
15
13
53
39
30
24
20
17
14
12
10
9
52
43
36
31
27
24
21
19
18
16
49
38
30
25
21
18
16
14
12
11
45
33
26
21
17
14
12
10
9
8
44
35
30
25
22
20
18
16
15
13
41
31
25
21
17
15
13
11
10
9
38
28
21
17
14
11
10
8
7
6
36
29
24
20
18
16
14
13
12
11
34
26
20
16
14
12
10
9
8
7
32
23
17
13
11
9
7
6
6
5
28
19
14
10
8
6
5
4
4
3
Coefficients of Utilization - Zonal Cavity Method
Effective Floor Cavity Reflectance 0.20
% Ceiling Rcc
80
70
50
30
10
0
Rw 70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0
0 80 80 80 80 78 78 78 78 74 74 74 71 71 71 68 68 68 67
1
2
3
4
5
6
7
8
9
10
73
66
59
54
49
45
42
39
36
34
69
60
52
45
40
36
32
29
27
24
66
55
46
39
34
30
26
23
21
19
64
51
42
35
29
25
22
19
17
15
71
64
58
52
48
44
40
38
35
33
68
59
51
45
39
35
32
29
26
24
65
54
46
39
33
29
26
23
21
19
63
51
41
34
29
25
22
19
17
15
65
56
49
43
38
34
31
28
25
23
63
53
44
38
33
29
25
23
20
19
61
49
41
34
29
25
21
19
17
15
62
54
47
41
37
33
30
27
25
23
61
51
43
37
32
28
25
22
20
18
59
48
40
33
28
24
21
19
17
15
60
52
45
40
35
32
29
26
24
22
59
49
42
36
31
27
24
22
20
18
57
47
39
33
28
24
21
19
17
15
56
46
38
31
27
23
20
17
15
14
REPORT NUMBER: CJL15AN
Lamps: 150 W High Pressure Sodium lamp with
30° Angle Dome Reflector
Coefficients of Utilization - Zonal Cavity Method
Effective Floor Cavity Reflectance 0.20
% Ceiling Rcc
% Walls
Zone
0-30
0-40
0-60
0-90
90-120
90-130
90-150
90-180
180-0
50
REPORT NUMBER: CJL15ST
Lamps: 150 W High Pressure Sodium lamp with
Standard Dome Reflector
Lumens % Lamp % Fixture
2509.94 15.7
23.5
4005.62 25.0
37.4
8185.92 51.2
76.5
10698.82 66.9
100.0
0.70
0.0
0.0
0.70
0.0
0.0
0.70
0.0
0.0
0.70
0.0
0.0
10699.52 66.9
100.0
CIE Type - Direct
70
Rw 70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0
1
2
3
4
5
6
7
8
9
10
Zonal Lumen Summary
Zone
0-30
0-40
0-60
0-90
90-120
90-130
90-150
90-180
180-0
80
0 85 85 85 85 79 79 79 79 69 69 69 59 59 59 50 50 50 46
% Walls
20-30
80-90
1077.10
90-100
153.91
100-110
155.65
110-120
52.23
120-130
8.33
130-140
0.10
140-150
0.00
150-160
0.00
160-170
0.00
170-180
0.00
REPORT NUMBER: CJL15G
Lamps: 150 W High Pressure Sodium lamp with Globe only *
80
70
50
30
10
0
Rw 70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0
0 73 73 73 73 71 71 71 71 67 67 67 64 64 64 61 61 61 60
1 64 59 55 52 61 58 54 51 54 51 49 51 49 47 49 47 45 43
2
3
4
5
6
7
8
9
10
56
51
46
42
38
35
33
30
28
50
43
37
32
29
26
23
21
19
44
36
30
26
22
20
17
16
14
40
31
25
21
18
15
13
12
10
54
49
44
40
37
34
31
29
27
48
41
36
32
28
25
23
21
19
43
36
30
25
22
19
17
15
14
39
31
25
21
18
15
13
12
10
46
39
34
30
27
24
22
20
18
41
34
29
25
21
19
17
15
13
38
30
24
20
17
15
13
11
10
43
37
32
28
25
23
21
19
17
39
33
28
24
21
18
16
14
13
36
29
24
20
17
15
13
11
10
41
35
30
27
24
22
20
18
17
38
31
26
23
20
17
16
14
13
35
28
23
19
17
14
12
11
10
33
27
22
18
15
13
11
10
9
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
Code•Master Jr.™ HID Factory Sealed Luminaire PSMH Photometric Data
Explosionproof, Dust-Ignitionproof
Integrally Ballasted. 50 W, 70 W, 100 W, 150 W HPS; 50 W, 70 W, 100 W, 175 W PSMH. 175 W MH V. Medium Base. For Use with Threaded Metal Conduit.
* Photometric data is based on a fixture with
a 175-watt clear Pulse Start Metal Halide
lamp (14,000 lumen), without guard. For
candlepower values of fixtures with other
PSMH lamps, use the following multipliers:
for a 100 W (8,500 lumen) PSMH lamp – 0.607;
Zone
0-10
10-20
20-30
Lumens
Total Luminaire Efficiency = 77.8%
46.64
176.99
380.01
CIE Type - General Diffuse
for a 70 W (5,000 lumen) PSMH lamp – 0.357.
For candlepower values of fixture with guard,
multiply by – 0.95.
REPORT NUMBER: CJP17G
Lamps: 175 W Pulse Start Metal Halide with Globe only *
Coefficients of Utilization - Zonal Cavity Method
30-40
480.30
40-50
1042.35
50-60
1252.88
% Ceiling Rcc
60-70
1378.40
% Walls
70-80
1611.81
80-90
90-100
100-110
110-120
120-130
130-140
140-150
150-160
160-170
170-180
1741.68
1758.28
1643.71
1371.76
694.24
27.13
3.14
0.67
0.08
0.03
Zone
Lumens
Total Luminaire Efficiency = 66.4%
281.17
CIE Type - Direct
1567.70
30-40
1691.30
0-180
1.42
40-50
2211.91
90-270
1.42
50-60
2339.53
Diagonal
1.76
60-70
1900.87
70-80
568.93
80-90
90-100
100-110
110-120
120-130
130-140
140-150
150-160
160-170
170-180
145.98
1.23
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
Zone
Spacing
Criteria
Plane
Total Luminaire Efficiency = 63.2%
238.28
CIE Type - Direct
10-20
739.68
20-30
1242.92
30-40
1491.36
0-180
2.10
40-50
1770.34
90-270
1.60
50-60
1739.56
Diagonal
1.62
60-70
1484.79
70-80
1197.57
689.02
254.20
105.48
35.72
41.95
8.72
6.06
4.53
2.20
0.68
Plane
Spacing
Criteria
Zonal Lumen Summary
Lumens % Lamp % Fixture
2220.87 12.7
20.1
3712.23 21.2
33.6
7222.13 41.3
65.3
10593.52 60.5
95.8
395.41
2.3
3.6
437.36
2.5
4.0
452.13
2.6
4.0
459.54
2.6
4.2
11053.05 63.2
100.0
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
67
56
48
41
36
32
28
26
23
21
62
49
40
33
28
24
21
19
17
15
58
43
34
27
22
19
16
14
12
11
67
59
53
48
43
40
36
34
31
29
62
52
44
38
33
29
26
24
21
20
58
45
37
31
26
23
20
17
15
14
54
40
31
25
21
18
15
13
11
10
53
44
37
32
28
25
22
20
18
17
49
39
31
26
22
19
17
15
13
12
46
35
27
22
18
15
13
11
9
8
45
36
31
26
23
20
18
17
15
14
42
32
26
22
18
16
14
12
11
10
39
29
22
18
15
12
10
9
8
7
37
30
25
21
19
16
15
13
12
11
35
27
21
17
15
13
11
10
9
8
33
24
18
14
12
10
8
7
6
5
29
20
15
12
9
7
6
5
4
4
Effective Floor Cavity Reflectance 0.20
80
70
50
30
10
0
Rw 70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0
0 79 79 79 79 77 77 77 77 74 74 74 71 71 71 68 68 68 66
1
2
3
4
5
6
7
8
9
10
72
65
59
54
49
45
42
39
36
34
69
60
52
46
40
36
32
29
27
25
66
55
46
39
34
30
26
23
21
19
64
51
42
35
29
25
22
19
17
16
70
64
57
52
48
44
41
38
35
33
67
58
51
45
40
35
32
29
26
24
65
54
46
39
34
29
26
23
21
19
63
51
41
35
29
25
22
19
17
16
65
56
49
43
38
34
31
28
26
24
63
52
44
38
33
29
26
23
21
19
61
49
41
34
29
25
22
19
17
15
62
54
47
41
37
33
30
27
25
23
60
51
43
37
32
28
25
22
20
18
59
48
40
34
29
25
22
19
17
15
60
52
45
40
35
32
29
26
24
22
58
49
42
36
31
28
25
22
20
18
57
47
39
33
28
24
21
19
17
15
56
46
38
32
27
23
20
18
16
14
REPORT NUMBER: CJP17AN
Lamps: 175 W Pulse Start Metal Halide with
30° Angle Dome Reflector *
Coefficients of Utilization - Zonal Cavity Method
Effective Floor Cavity Reflectance 0.20
% Ceiling Rcc
% Walls
Zone
0-30
0-40
0-60
0-90
90-120
90-130
90-150
90-180
180-0
73
64
57
52
47
43
40
37
34
32
% Ceiling Rcc
Lumens % Lamp % Fixture
2763.57 15.8
23.8
4454.87 25.5
38.3
9006.31 51.5
77.5
11622.09 66.4
100.0
1.23
0.0
0.0
1.23
0.0
0.0
1.23
0.0
0.0
1.23
0.0
0.0
11623.32 66.4
100.0
Lumens
0
Coefficients of Utilization - Zonal Cavity Method
Zonal Lumen Summary
0-10
10
REPORT NUMBER: CJP17ST
Lamps: 175 W Pulse Start Metal Halide with
Standard Dome Reflector *
% Walls
Zone
0-30
0-40
0-60
0-90
90-120
90-130
90-150
90-180
180-0
30
80
70
50
30
10
0
Rw 70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0
0 75 75 75 75 73 73 73 73 69 69 69 65 65 65 62 62 62 61
1
2
3
4
5
6
7
8
9
10
66
60
54
49
45
41
38
35
33
31
63
53
46
41
36
32
29
26
24
22
59
48
40
34
30
26
23
21
19
17
56
44
36
30
25
22
19
17
15
13
64
58
52
47
43
40
37
34
32
30
61
52
45
39
35
31
28
26
24
22
58
47
40
34
29
26
23
20
18
17
55
43
35
29
25
21
19
17
15
13
58
49
43
38
33
30
27
25
23
21
55
45
38
33
28
25
22
20
18
16
53
42
34
29
24
21
18
16
15
13
55
47
41
36
32
29
26
24
22
20
53
43
37
31
27
24
21
19
17
16
51
41
33
28
24
21
18
16
14
13
52
44
39
34
30
27
25
23
21
19
50
42
35
30
26
23
21
19
17
15
49
39
32
27
23
20
18
16
14
13
47
38
31
26
22
19
16
14
13
12
1215
Lighting: Explosionproof — Area — HID
914.71
20-30
80-90
90-100
100-110
110-120
120-130
130-140
140-150
150-160
160-170
170-180
1
2
3
4
5
6
7
8
9
10
Lumens % Lamp % Fixture
603.64
3.4
4.4
1083.94
6.2
8.0
3379.18 19.3
24.8
8111.07 46.3
59.6
4773.75 27.3
35.1
5467.99 31.2
40.2
5498.26 31.4
40.2
5499.05 31.4
40.4
13610.12 77.8
100.0
10-20
50
0 85 85 85 85 79 79 79 79 69 69 69 59 59 59 51 51 51 46
Zonal Lumen Summary
Zone
0-30
0-40
0-60
0-90
90-120
90-130
90-150
90-180
180-0
70
Rw 70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0
Lighting
0-10
Effective Floor Cavity Reflectance 0.20
80
Code•Master 2™ HID Factory Sealed Luminaires
Explosionproof, Dust-Ignitionproof
Integrally Ballasted. 50 W, 70 W, 100 W, 150 W, 250 W, 400 W HPS; 175 W, 250 W, 320 W, 350 W, 400 W PSMH; 175 W, 250 W, 400 W MH V.
Mogul Base. For use with threaded metal conduit.
NEC:
Class I, Division 1 and 2, Groups C, D
Class II, Division 1 and 2, Groups E, F, G
Class III
Marine Type Electric Fixtures
Outside Type (Salt Water)
CEC: V
Class I, Division 1 and 2, Groups B, C, D
Class I, Zone 1 and 2; IIB, IIA
Class II, Division 1, Groups E, F, G
Class II, Division 2, Groups F, G
Class III
CSA Type 4X
Exd IIB, Zone 1
Applications
• Ideal for use in chemical and petrochemical plants, such as
manufacturers of plastics, paints and thinners; in refineries; and
in other process areas where ignitable vapors, dust, moisture
and corrosive elements may be present.
• Suitable for use in wet locations.
Lighting: Explosionproof — Area — HID
Lighting
Features
• Fixtures operate safely in high ambient temperatures. For
example, in Class I areas the 150 W HPS fixture operates
at a maximum temperature of 248 ˚ F/120 °C in a 149 ˚F/
65 °C ambient (212 ˚F/100 °C temperature in a 104 °F/40 °C
ambient).
• Arrangement of heat-producing components results in
more efficient heat dissipation for cooler fixture operation.
• Patented “wireless” design. Threading of fixture unit onto
mounting hood makes electrical connection. Only wiring
required is attaching two wires to connection block in mounting
hood.
• Connection block is easily wired: (a) loosen two screws, (b)
make wire connections and (c) re-position connection block.
• Safe, easy servicing without disconnecting any wiring.
“Wireless” fixture unit easily threads off mounting hood for
convenient servicing or for immediate replacement with a
“stand-by” unit.
• Acme double-lead threads speed installation and fixture
removal from mounting hood – only half as many turns are
required as for single-lead threads. The threads do not stick or
gall, eliminating the troublesome problems often encountered
with single lead threads during fixture unit removal.
• All threaded joints are flame-tight.
• Integrally ballasted HID lighting fixtures; separate ballasts
not required.
• Factory sealed. External seals not required.
• Strategic location of lamp socket in combination with the
interior prism design of the glass globe provides optimum
light distribution and control.
• Superior corrosion resistance, with epoxy powder coat finish.
• Porcelain socket with nickel-plated phosphor bronze
screw shell. Assures long trouble-free operation in high ambient
areas.
• Choice of mountings: pendant, ceiling, bracket and stanchion.
• Fiberglass-reinforced polyester reflectors, in standard
dome, deep dome or 30° angle, are ideal in installations
where luminaire is subject to exceptionally severe corrosive
atmospheres. The high bay aluminum reflector is indicated in
installations where mounting height from work plane ranges
from 20 feet/6 meters and higher.
• Optional guards protect globes from damage. Secured to fixture
with three screws.
• Light sources: high pressure sodium, pulse start metal halide or
metal halide. HPS is excellent where long lamp life is required.
HPS provides high lumens per watt and is less expensive to
operate. PSMH/MH is desirable where colors of illuminated
areas must be close to natural. PSMH/MH provides better color
rendition, increased lumen output, longer lamp life, and faster
restrike after momentary power interruption.
• A wide range of ballasts and voltages are available for both
domestic and export applications.
• Ballasts operate at low temperatures – PSMH: -20 °F/-29 ˚C;
HPS: -40 °F/-40 ˚C; MH: -31 °F/-35 ˚C.
• 50 W through 150 W high pressure sodium ballasts are high
reactance, high power factor type.
1216
Standard Materials
• Ballast bodies and guards: copperfree (4/10 of 1% max.)
aluminum
• Pendant mounting hoods: diecast copperfree (4/10 of 1% max.)
aluminum
• Ceiling, bracket and stanchion mounting hoods: sand cast
copperfree (4/10 of 1% max.) aluminum
• Reflectors: aluminum or fiberglass reinforced polyester
Standard Finishes
• Ballast bodies, guards and mounting hoods: epoxy powder
coat finish, electrostatically applied for complete, uniform
corrosion protection
Options
• Fuses for field installation can be ordered by catalog number
from fuse kit table.
• Quartz Auxiliary Emergency Lamp for PSMH/MH and HPS
fixtures. Relay switch installed in fixture. Add suffix -E to fixture
catalog number.
• Smart Hot Restrike Option available for 50 W through 150 W
HPS only. Add suffix -SR.
• Hot Restrike Option available for 50 W through 150 W HPS only.
Add suffix –R.
• Smart Starter Option available for 50 W through 400 W HPS
and PSMH/MH. Add suffix –S.
Certifications and Compliances
•
•
•
•
UL Standard: UL 1598, UL 844
UL Listed: E10444
CSA Standard: C22.2 No. 250, C22.2 No. 137
CSA Certified: 025428
V CSA Certification only.
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
Code•Master 2™ HID Factory Sealed Luminaire Technical Data
Explosionproof, Dust-Ignitionproof
Integrally Ballasted. 50 W, 70 W, 100 W, 150 W, 250 W, 400 W HPS; 175 W, 250 W, 320 W, 350 W, 400 W PSMH; 175 W, 250 W, 400 W MH V.
Mogul Base. For use with threaded metal conduit.
NEC:
Class I, Division 1 and 2, Groups C, D
Class II, Division 1 and 2, Groups E, F, G
Class III
Marine Type Electric Fixtures
Outside Type (Salt Water)
CSA Type 4X
Exd IIB, Zone 1
CEC: V
Class I, Division 1 and 2, Groups B, C, D
Class I, Zone 1 and 2; IIB, IIA
Class II, Division 1, Groups E, F, G
Class II, Division 2, Groups F, G
Class III
Classified Area Suitability of Code•Master 2 Series HID Fixtures — Suitability includes use of reflector
Lamp
Type
Lamp
Watts
Class I, Division 1 & 2 With Globe or with
Globe & Reflector UL/NEC/CEC Temp. Ident. No.
Supply Wire Ambient Temp
NEC
CEC V
(°F/˚°C)
(°F/°˚C)
Nameplate Marking
Groups
Groups
50
Metal Halide V
Nameplate Marking
Groups
C,D
B, C, D
T4
E,F,G
50
167/75
131/55
T5
C,D
B, C, D
—
—
50
185/85
149/65
T5
C,D
B, C, D
—
—
70
140/60
104/40
T6
C,D
B, C, D
T4
E,F,G
70
167/75
131/55
T5
C,D
B, C, D
—
—
70
185/85
149/65
T5
C,D
B, C, D
—
—
100
122/60
104/40
T5
C,D
B, C, D
T4
E,F,G
100
167/75
131/55
T5
C,D
B, C, D
—
—
100
185/85
149/65
T4A
C,D
B, C, D
—
—
150
122/60
104/40
T5
C,D
B, C, D
T3A
E,F
150
167/75
131/55
T4A
C,D
B, C, D
T3
—
250
167/75
104/40
T3C
C,D
B, C, D
—
—
250
167/75
131/55
T3C
C,D
B, C, D
—
—
400
185/85
104/40
T3C
C,D
B, C, D
—
—
175
167/75
104/40
T4
C,D
B, C, D
T3C
E,F,G
250
167/75
104/40
T4
C,D
B, C, D
T3A
E,F
320
167/75
104/40
T3C
C,D
B, C, D
—
—
350
167/75
104/40
T3C
C,D
B, C, D
—
—
400
167/75
104/40
T3C
C,D
B, C, D
—
—
175
167/75
104/40
T4
—
B, C, D
T3C
E, F, G
250
167/75
104/40
T4
—
B, C, D
T3A
E, F
400
167/75
104/40
T3C
—
B, C, D
—
—
Lighting: Explosionproof — Area — HID
Pulse Start
Metal Halide
T6
104/40
Lighting
High
Pressure
Sodium
122/60
Class II, Division 1 & 2
With Globe or with Globe & Reflector
UL/NEC/CEC Temp. Ident. No. ➊
“T” Numbers Represent the Maximum Surface Temperature for Class I, Division 1 Locations and
Maximum Surface Temperature Under Dust Blanket for Class II, Division 1 Locations.
“T”
Number
T1
350
325
T2
T2A
T2B
T2C
T2D
T3
T3A
T3B
T3C
T4
T4A
T5
T6
Temp.
Range
(°F)
664842
619662
574617
538572
502536
448500
421446
394419
358392
331356
322329
277320
250275
214248
18712
185
Temp.
Range
(°C)
351450
326350
301325
281300
261280
231260
216230
201215
181200
166180
161165
136160
121135
101120
86100
85
NOTE: The maximum operating temperature of the fixture must not exceed the ignition temperature of the gas, vapor or dust to be encountered per the National
Electrical Code and the Canadian Electrical Code.
➊ Applies to Code•Master 2 only.
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
1217
Code•Master 2™ HID Factory Sealed Luminaires
Explosionproof, Dust-Ignitionproof. Groups C and D Applications
Integrally Ballasted. 50 W, 70 W, 100 W, 150 W, 250 W, 400 W HPS; 175 W, 250 W, 320 W, 350 W, 400 W PSMH.
Mogul Base. For use with threaded metal conduit.
NEC:
Class I, Division 1 and 2, Groups C, D
Class II, Division 1 and 2, Groups E, F, G
Class III
Marine Type Electric Fixtures
Outside Type (Salt Water)
Lamp
Watts
ANSI Lamp Type
HPS
PSMH
S68
—
Catalog Number ➋➌
Hub Size
(Inches)
HPS
PSMH
3/4
CLP5075 ➊
—
1
CLP5010 ➊
—
3/4
CLP7075
—
Pendant — One Hub, Rigid or Flexible Mounting
50
70
100
Lighting: Explosionproof — Area — HID
Lighting
150
175
S62
S54
S55
—
—
—
—
M152
250
S50
M153
320
—
M154
350
—
M131
400
S51
M155
50
S68
—
1
CLP7010
—
3/4
CLP1075
—
1
CLP1010
—
3/4
CLP1575
—
1
CLP1510
3/4
1
—
—
CPP1775
—
CPP1710
3/4
CLP2575
CPP2575
1
CLP2510
CPP2510
CPP3275
3/4
—
1
—
CPP3210
3/4
—
CPP3575
1
—
CPP3510
3/4
CLP4075
CPP4075
1
CLP4010
CPP4010
Ceiling — Four Hubs, Three Close-Up Plugs
70
S62
—
100
S54
—
150
S55
—
175
—
M152
250
320
350
400
S50
—
—
S51
M153
M154
M131
M155
3/4
CLC5075 ➊
—
1
CLC5010 ➊
—
3/4
CLC7075
—
1
CLC7010
—
3/4
CLC1075
—
1
CLC1010
—
3/4
CLC1575
—
1
CLC1510
—
3/4
—
CPC1775
1
—
CPC1710
3/4
CLC2575
1
CLC2510
3/4
—
CPC2575
CPC2510
CPC3275
1
—
CPC3210
3/4
—
CPC3575
—
CPC3510
1
3/4
CLC4075
CPC4075
1
CLC4010
CPC4010
➊ Add voltage -MT for 120/208/240/277 V. For 480 V, contact your sales representative.
➋ Add voltage suffix -MT for -120/208/240/277 V; or -480 for 480 V.
To order fixture with guard, add suffix -G (before adding voltage suffix).
Shaded items are suitable for Class I, Group D ONLY.
1218
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
Code•Master 2™ HID Factory Sealed Luminaires
Explosionproof, Dust-Ignitionproof. Groups C and D Applications
Integrally Ballasted. 50 W, 70 W, 100 W, 150 W, 250 W, 400 W HPS; 175 W, 250 W, 320 W, 350 W, 400 W PSMH.
Mogul Base. For use with threaded metal conduit.
NEC:
Class I, Division 1 and 2, Groups C, D
Class II, Division 1 and 2, Groups E, F, G
Class III
Marine Type Electric Fixtures
Outside Type (Salt Water)
ANSI Lamp Type
Lamp
Watts
HPS
PSMH
50
S68
—
70
S62
—
Catalog Number ➋➌
Hub Size
(Inches)
HPS
PSMH
3/4
CLB5075 ➊
—
1
CLB5010 ➊
—
3/4
CLB7075
—
1
CLB7010
—
3/4
CLB1075
—
1
CLB1010
—
3/4
CLB1575
—
1
CLB1510
Bracket - Four Hubs, Three Close-Up Plugs
100
150
—
S55
—
—
M152
S50
M153
320
—
M154
350
—
M131
—
CPB1775 ➋
1
—
CPB1710 ➋
3/4
CLB2575
CPB2575 ➋
1
CLB2510
CPB2510 ➋
3/4
—
CPB3275 ➋
1
—
CPB3210 ➋
3/4
—
CPB3575 ➋
1
—
CPB3510 ➋
3/4
CLB4075
CPB4075 ➋
1
CLB4010
CPB4010 ➋
400
S51
M155
50
S68
—
1-1/4 or 1-1/2 ➍
CLS50150 ➊
—
70
S62
—
1-1/4 or 1-1/2 ➍
CLS70150
—
100
S54
—
1-1/4 or 1-1/2 ➍
CLS10150
—
150
S55
—
1-1/4 or 1-1/2 ➍
CLS15150
—
175
—
M152
1-1/4 or 1-1/2 ➍
250
S50
M153
1-1/4 or 1-1/2 ➍
320
—
M154
1-1/4 or 1-1/2 ➍
—
CPS32150 ➋
350
—
M131
1-1/4 or 1-1/2 ➍
—
CPS35150 ➋
400
S51
M155
1-1/4 or 1-1/2 ➍
CLS40150 ➋
CPS40150 ➋
25° Stanchion - One Hub
—
CLS25150
CPS17150 ➋
CPS25150 ➋
➊ Add voltage -MT for 120/208/240/277 V. For 480 V, contact your sales representative.
➋ Add voltage suffix -MT for -120/208/240/277 V; or -480 for 480 V.
To order fixture with guard, add suffix -G (before adding voltage suffix).
➍ 1-1/2” tapped hub furnished with 1-1/2” to 1-1/4” reducer.
Shaded items are suitable for Class I, Group D ONLY.
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
1219
Lighting: Explosionproof — Area — HID
250
—
3/4
Lighting
175
S54
Code•Master 2™ HID Factory Sealed Luminaires V
Explosionproof, Dust-Ignitionproof. Groups B, C and D Applications
Integrally Ballasted. 70 W, 100 W, 150 W, 250 W, 400 W HPS; 175 W, 250 W, 320 W, 350 W, 400 W PSMH; 175 W, 250 W, 400 W MH.
Mogul Base. For use with threaded metal conduit.
CSA Type 4X
Exd IIB, Zone 1
CEC: V
Class I, Division 1 and 2, Groups B, C, D
Class I, Zone 1 and 2; IIB, IIA
Class II, Division 1, Groups E, F, G
Class II, Division 2, Groups F, G
Class III
ANSI Lamp Type
Lamp
Watts
HPS
PSMH
MH
S62
—
—
Hub
Size
(Inches)
Catalog Number ❶❷
HPS
PSMH
MH
3/4
CLP7075TTCN
—
—
1
CLP7010TTCN
—
—
3/4
CLP1075TTCN
—
—
1
CLP1010TTCN
—
—
3/4
CLP1575TTCN
—
—
1
CLP1510TTCN
—
Pendant — One Hub, Rigid or Flexible Mounting
70
100
S54
—
—
150
S55
—
—
Lighting
175
250
Lighting: Explosionproof — Area — HID
320
350
400
—
S50
—
—
M152
M153
M154
M131
M57
M58
—
—
S51
M155
M59
S62
—
—
3/4
—
—
CPP1775TTCN
CHP1775TTCN
—
CPP1710TTCN
CHP1710TTCN
3/4
CLP2575TTCN
CPP2575TTCN
CHP2575TTCN
1
CLP2510TTCN
CPP2510TTCN
CHP2510TTCN
1
3/4
—
CPP3275TTCN
—
1
—
CPP3210TTCN
—
3/4
—
CPP3575TTCN
—
—
CPP3510TTCN
1
—
3/4
CLP4075TTCN
CPP4075TTCN
CHP4075TTCN
1
CLP4010TTCN
CPP4010TTCN
CHP4010TTCN
3/4
CLC7075TTCN
—
—
1
CLC7010TTCN
—
—
3/4
CLC1075TTCN
—
—
1
CLC1010TTCN
—
—
3/4
CLC1575TTCN
—
—
1
CLC1510TTCN
Ceiling — Four Hubs, Three Close-Up Plugs
70
100
150
175
250
320
S54
S55
—
S50
—
—
—
M152
M153
M154
—
—
M57
M58
—
350
—
M131
—
400
S51
M155
M59
3/4
—
—
—
CPC1775TTCN
CHC1775TTCN
—
CPC1710TTCN
CHC1710TTCN
3/4
CLC2575TTCN
CPC2575TTCN
CHC2575TTCN
1
CLC2510TTCN
CPC2510TTCN
CHC2510TTCN
1
3/4
—
CPC3275TTCN
—
1
—
CPC3210TTCN
—
3/4
—
CPC3575TTCN
—
1
—
CPC3510TTCN
—
3/4
CLC4075TTCN
CPC4075TTCN
CHC4075TTCN
1
CLC4010TTCN
CPC4010TTCN
CHC4010TTCN
➊ Change voltage suffix -TT (120/277/347 V) to -MT for 120/208/240/277 V, -C2 for 208 V, -C3 for 240 V, -C6 for 480 V, or -C7 for 600 V, V
❷ To order fixture with guard, add suffix -G (before adding voltage suffix).
V CSA Certification only.
Shaded items are suitable for Class I, Group D ONLY.
1220
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
Code•Master 2™ HID Factory Sealed Luminaires V
Explosionproof, Dust-Ignitionproof. Groups B, C and D Applications
Integrally Ballasted. 70 W, 100 W, 150 W, 250 W, 400 W HPS; 175 W, 250 W, 320 W, 350 W, 400 W PSMH; 175 W, 250 W, 400 W MH.
Mogul Base. For use with threaded metal conduit.
CSA Type 4X
Exd IIB, Zone 1
CEC: V
Class I, Division 1 and 2, Groups B, C, D
Class I, Zone 1 and 2; IIB, IIA
Class II, Division 1, Groups E, F, G
Class II, Division 2, Groups F, G
Class III
ANSI Lamp Type
Lamp
Watts
HPS
PSMH
MH
Hub
Size
(Inches)
Catalog Number ❶❷
HPS
PSMH
MH
Bracket - Four Hubs, Three Close-Up Plugs
70
S62
—
—
100
S54
—
—
150
S55
—
—
175
—
M152
M57
320
—
—
M153
M58
M154
—
M131
—
—
—
CLB7010TTCN
—
—
3/4
CLB1075TTCN
—
—
1
CLB1010TTCN
—
—
3/4
CLB1575TTCN
—
—
1
CLB1510TTCN
—
—
3/4
—
CPB1775TTCN
CHB1775TTCN
1
—
CPB1710TTCN
CHB1710TTCN
3/4
CLB2575TTCN
CPB2575TTCN
CHB2575TTCN
1
CLB2510TTCN
CPB2510TTCN
CHB2510TTCN
3/4
—
CPB3275TTCN
—
1
—
CPB3210TTCN
—
3/4
—
CPB3575TTCN
—
—
CPB3510TTCN
1
—
3/4
CLB4075TTCN
CPB4075TTCN
CHB4075TTCN
1
CLB4010TTCN
CPB4010TTCN
CHB4010TTCN
400
S51
M155
M59
70
S62
—
—
1-1/4 or 1-1/2 ➌
CLS70150TTCN
—
—
100
S54
—
—
1-1/4 or 1-1/2 ➌
CLS10150TTCN
—
—
150
S55
—
—
1-1/4 or 1-1/2 ➌
CLS15150TTCN
—
—
175
—
M152
M57
1-1/4 or 1-1/2 ➌
—
250
S50
M153
M58
1-1/4 or 1-1/2 ➌
320
—
M154
—
1-1/4 or 1-1/2 ➌
—
CPS32150TTCN
—
350
—
M131
—
1-1/4 or 1-1/2 ➌
—
CPS35150TTCN
—
400
S51
M155
M59
1-1/4 or 1-1/2 ➌
25° Stanchion - One Hub
CPS17150TTCN CHS17150TTCN
CLS25150TTCN CPS25150TTCN CHS25150TTCN
CLS40150TTCN CPS40150TTCN CHS40150TTCN
➊ Change voltage suffix -TT (120/277/347 V) to -MT for 120/208/240/277 V, -C2 for 208 V, -C3 for 240 V, -C6 for 480 V, or -C7 for 600 V, V
❷ To order fixture with guard, add suffix -G (before adding voltage suffix).
➌ 1-1/2” tapped hub furnished with 1-1/2” to 1-1/4” reducer.
V CSA Certification only.
Shaded items are suitable for Class I, Group D ONLY.
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
1221
Lighting: Explosionproof — Area — HID
350
S50
CLB7075TTCN
1
Lighting
250
3/4
Code•Master 2™ HID Factory Sealed Luminaire Mounting Hoods and Fixture Units
Explosionproof, Dust-Ignitionproof
Integrally Ballasted. 50 W, 70 W, 100 W, 150 W, 250 W, 400 W HPS; 175 W, 250 W, 320 W, 350 W, 400 W PSMH; 175 W, 250 W, 400 W MH V.
Mogul Base. For use with threaded metal conduit.
NEC:
Class I, Division 1 and 2, Groups C, D
Class II, Division 1 and 2, Groups E, F, G
Class III
Marine Type Electric Fixtures
Outside Type (Salt Water)
CEC: V
Class I, Division 1 and 2, Groups B, C, D
Class I, Zone 1 and 2; IIB, IIA
Class II, Division 1, Groups E, F, G
Class II, Division 2, Groups F, G
Class III
CSA Type 4X
Exd IIB, Zone 1
Mounting Hoods
Hub Size (Inches)
Catalog Number
Pendant — One Hub
3/4
CAP-75
1
CAP-100
3/4
CAC-75
1
CAC-100
3/4
CALB-75
1
CALB-100
Lighting
Ceiling — Four Hubs, Three Close-Up Plugs
Bracket — Four Hubs, Three Close-Up Plugs
Lighting: Explosionproof — Area — HID
25˚ Stanchion — One Hub
1-1/4 or 1-1/2 ➊
CAS-150
Mounting Adapter with Connection Block
Permits use of existing A-51 mounting hoods (AAC Ceiling
or AALB Bracket) with the new Code•Master 2 Fixture Unit.
After removing existing fixture unit and adapter, screw in
the new CMAD-1 Adapter. Then thread new fixture unit into
the CMAD-1.
Fixture Units
Ballast body with globe. Indicate voltage desired by adding voltage suffix to fixture unit catalog number listed below.
Add Voltage Suffixes
Lamp
Fixture Unit
Type
Watts
Number
120/208/240/277
120/277/347 V➌
50
CMBL50
MT
TTCN
70
CMBL70
MT
TTCN
High Pressure Sodium
100
CMBL100
MT
TTCN
High Power Factor
150
CMBL150
MT
TTCN
(Min. P.F. 90%)
250
CMBL250
MT
TTCN
400
CMBL400
MT
TTCN
175
CMBP175
MT
TTCN
250
CMBP250
MT
TTCN
Pulse Start Metal Halide
Constant Wattage
320
CMBP320
MT
TTCN
(Min. P.F. 90%)
350
CMBP350
MT
TTCN
400
CMBP400
MT
TTCN
175
CMBH175
MT
TT
Metal Halide V
250
CMBH250
MT
TT
Constant Wattage
(Min. P.F. 90%)
400
CMBH400
MT
TT
CMAD-1
480 V
—
48
48
48
48
48
48
48
48
48
48
C6
C6
C6
➊ 1-1/2” Tapped hub furnished with 1-1/2” to 1-1/4” reducer.
➋ Add suffix -R for “Hot Restrike” and -S for “Smart Starter” options.
➌ Change voltage suffix -TTCN to -MTCN for 120/208/240/277 V, -C2 for 208 V, -C3 for 240 V, -C6 for 480 V, or -C7 for 600 V, V
V CSA Certification only.
Shaded items are suitable for Class I, Group D ONLY.
1222
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
Code•Master 2™ HID Factory Sealed Luminaire Accessories
Explosionproof, Dust-Ignitionproof
Integrally Ballasted. 50 W, 70 W, 100 W, 150 W, 250 W, 400 W HPS; 175 W, 250 W, 320 W, 350 W, 400 W PSMH; 175 W, 250 W, 400 W MH V.
Mogul Base. For use with threaded metal conduit.
Description
Catalog Number
Polyester Reflectors — 50 W - 400 W
Standard Dome
CMR-4ST
Deep Dome
CMR-4DD
30˚ Angle
CMR-4AN
Aluminum High Bay Reflectors — 50 W - 400 W
CMR-4HB
Lighting
Prismatic Glass Globes — 50 W - 400 W
CGL-250
250, 400 W HPS; 320, 350, 400 W PSMH; 400 W MH
CGL-400
50, 70, 100, 150 W HPS; 175, 250 W PSMH; 175, 250 W MH
CGU2
250, 400 W HPS; 320, 350, 400 W PSMH; 400 W MH
CGU4
Aluminum Guards — 50 W - 400 W
Replacement Sockets — 50 W - 400 W (Mogul Base)
For all Code•Master 2 HID fixtures
CMS-400
Connection Block – 50 W through 400 W
For all Code•Master 2 HID fixtures
VPT-7
Quartz Emergency Option for Pulse Start Metal Halide and High Pressure Sodium Fixtures
Fixtures can be supplied with a socket to accept a 150 W or 250 W, 120 V quartz lamp (lamp not included). This D.C. bayonet base socket is
in addition to the standard lamp socket, independent of the lighting fixture voltage.
Add suffix -E
HPS Smart Hot Restrike
Smart Hot Restrike will immediately restrike an HPS lamp when power is restored after a momentary power interruption. The smart function
removes the hot restrike ignitor from the circuit if the lamp burns out or is removed from the socket. Eliminates starter failures caused by
prolonged operation with cycling or failing lamps and simplifies finding their location, reducing maintenance and repair costs.
Optional for fixture watts of 50, 70, 100 or 150 (HPS only)
Add suffix -SR
HPS Hot Restrike
Restrikes HPS lamp immediately when power is restored after a momentary power interruption.
Optional for fixture watts of 50, 70, 100 or 150 (HPS only)
Add suffix -R
HPS Smart Starter
Smart Starter is for HPS fixtures only. Incorporates a 1-1/2-minute timer and performs as a conventional starter to normally start lamp.
Removes itself from circuit if lamp burns out or is removed from socket. Eliminates starter failures caused by prolonged operation with
cycling or failing lamps and simplifies finding their location which reduces maintenance and repair costs.
Optional for all HPS fixtures.
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
Add suffix -S
1223
Lighting: Explosionproof — Area — HID
50, 70, 100, 150 W HPS; 175, 250 W PSMH; 175, 250 W MH
Code•Master 2™ HID Factory Sealed Luminaire Ballast and Fuse Data
Explosionproof, Dust-Ignitionproof
Integrally Ballasted. 50 W, 70 W, 100 W, 150 W, 250 W, 400 W HPS; 175 W, 250 W, 320 W, 350 W, 400 W PSMH; 175 W, 250 W, 400 W MH V.
Mogul Base. For use with threaded metal conduit.
NEC:
Class I, Division 1 and 2, Groups C, D
Class II, Division 1 and 2, Groups E, F, G
Class III
Marine Type Electric Fixtures
Outside Type (Salt Water)
Lamp
Watts
50
Lighting
70
Lighting: Explosionproof — Area — HID
100
150
175
250
320
350
400
Volts
120
208
240
277
347
480
120
208
240
277
347
480
120
208
240
277
347
480
120
208
240
277
347
480
120
208
240
277
347
480
120
208
240
277
347
480
120
208
240
277
347
480
120
208
240
277
347
480
120
208
240
277
347
480
High Pressure
Sodium ➊
Start
Operating
0.58
0.58
0.35
0.33
0.31
0.29
0.25
0.25
—
—
—
—
0.90
0.82
0.50
0.48
0.44
0.44
0.35
0.36
0.30
0.30
0.21
0.21
1.30
1.15
0.76
0.67
0.66
0.58
0.60
0.50
0.45
0.39
0.33
0.29
2.00
1.66
1.16
0.96
1.00
0.83
0.88
0.75
0.52
0.56
0.50
0.44
—
—
—
—
—
—
—
—
—
—
—
—
1.75
2.70
1.00
1.50
0.85
1.30
0.75
1.15
0.60
0.93
0.40
0.65
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
3.10
3.90
1.80
2.25
1.60
1.95
1.35
1.70
1.00
1.32
0.80
1.00
CEC: V
Class I, Division 1 and 2, Groups B, C, D
Class I, Zone 1 and 2; IIB, IIA
Class II, Division 1, Groups E, F, G
Class II, Division 2, Groups F, G
Class III
Ballast Amps
Pulse Start Metal Halide
Super CWA
Start
Operating
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
1.10
1.86
0.75
1.23
0.65
0.98
0.55
0.87
0.25
0.65
0.25
0.50
1.96
2.50
1.13
1.45
0.98
1.25
0.85
1.10
0.62
0.90
0.32
0.67
3.30
3.25
1.90
1.90
1.60
1.65
1.40
1.40
0.70
1.10
0.45
0.85
3.60
3.70
2.10
2.10
1.80
1.80
1.60
1.60
0.70
1.01
0.60
0.90
3.50
4.00
2.00
2.30
1.75
2.00
1.50
1.75
1.10
1.35
0.75
1.00
Metal Halide
CWA
Start
Operating
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
1.30
1.80
0.75
1.10
0.65
0.90
0.55
0.80
0.50
0.65
—
—
1.20
2.60
0.65
1.50
0.60
1.30
0.50
1.12
0.80
0.90
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
3.25
4.00
1.90
2.30
1.65
2.00
1.40
1.75
1.20
1.40
—
—
CSA Type 4X
Exd IIB, Zone 1
Fuse Kit Catalog Number
Fuse
Quantity
Required
1
2
2
1
—
—
1
2
2
1
1
2
1
2
2
1
1
2
1
2
2
1
1
2
1
2
2
1
1
2
1
2
2
1
1
2
1
2
2
1
1
2
1
2
2
1
1
2
1
2
2
1
1
2
HPS
CF-5
CF-3
CF-3
CF-2
—
—
CF-5
CF-3
CF-3
CF-2
CF-2
CF-2
CF-8
CF-5
CF-5
CF-3
CF-3
CF-3
CF-10
CF-5
CF-5
CF-5
CF-5
CF-3
—
—
—
—
—
—
CF-8
CF-5
CF-5
CF-5
CF-5
CF-2
—
—
—
—
—
—
—
—
—
—
—
—
CF-15
CF-8
CF-5
CF-5
CF-5
CF-5
PSMH
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
CF-5
CF-3
CF-3
CF-2
CF-2
CF-2
CF-8
CF-5
CF-5
CF-3
CF-3
CF-2
CF-8
CF-6
CF-5
CF-5
CF-5
CF-3
CF-10
CF-8
CF-5
CF-5
CF-5
CF-3
CF-10
CF-8
CF-5
CF-5
CF-5
CF-3
MH V
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
CF-5
CF-3
CF-3
CF-2
CF-2
—
CF-8
CF-5
CF-5
CF-3
CF-3
—
—
—
—
—
—
—
—
—
—
—
—
—
CF-10
CF-8
CF-5
CF-5
CF-5
—
Fuse Kit includes fuse, fuse holder and necessary hardware for field installation. Mounts easily in ballast body with one screw. Order one fuse for 120 and 277 V,
and 2 fuses for 208, 240 and 480 V. CF-2 = 2 amp; CF-3 = 3 amp; CF-5 = 5 amp; CF-6 = 6 amp; CF-8 = 8 amp; CF-10 = 10 amp
➊ 50 through 150 W HPS have H.P.F. High Reactance ballasts; 250 W and 400 W HPS have CWA ballasts.
V CSA Certification only.
1224
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
Code•Master 2™ HID Factory Sealed Luminaire Dimensions
Explosionproof, Dust-Ignitionproof
Integrally Ballasted. 50 W, 70 W, 100 W, 150 W, 250 W, 400 W HPS; 175 W, 250 W, 320 W, 350 W, 400 W PSMH; 175 W, 250 W, 400 W MH V.
Mogul Base. For use with threaded metal conduit.
Pendant
Ceiling
Bracket
0.41"/
10.4 mm Dia.
4.58"/
116.3 mm
2.46"/
62.5 mm
25° Stanchion
9.5"/
241.3 mm
2.28"/
57.9 mm
6.10"/
154.9 mm
4.25"/
108.0 mm
4.92"/
125.0 mm Sq.
4.50"/
114.3 mm
3.91"/
99.3 mm
4.00"/
101.6 mm
1.23"/
31.2 mm
3.46"/
87.9 mm
3.92"/
99.6 mm
5.92"/
151.1 mm
0.94"/
23.9 mm
9.86"/
250.4 mm
1.79"/
45.5 mm
4.5"/
60.5 mm Dia.
2.38"/
60.5 mm Dia.
11.5"/
292.1 mm
13.75"/
349.3 mm
9.86"/
250.4 mm
Lighting
9.86"/
250.4 mm
Pendant
Ceiling
Bracket
25° Stanchion
A
B
C
D
A
B
C
D
A
B
C
D
A
B
C
21.50/ 20.50/ 12.00/ 17.61/ 21.61/ 20.61/ 12.00/ 17.61/ 21.86/ 20.86/ 17.50/ 17.61/ 19.50/ 18.70/ 16.00/
50-250 W ➊ 546.1 520.7 304.8 447.3 548.9 523.5 304.8 447.3 555.2 529.8 444.5 447.3 495.3 475.0 406.4
24.50/ 23.50/ 12.00/ 20.36/ 24.36/ 23.36/ 12.00/ 20.36/ 24.61/ 23.61/ 17.50/ 20.36/ 22.20/ 21.20/
250-400 W ➋ 522.3 596.9 304.8 507.1 618.7 507.1 304.8 507.1 625.1 599.7 444.5 507.1 563.9 538.5
17.50/
444.5
Fixture and Accessory Weights lbs/kgs
Fixture Size
50 W through 175 W
250 W PSMH/MH
250 W HPS
320 W, 350 W and 400 W PSMH, 400 W MH
Mounting Hood Weights lbs/kgs
Fixture Weight
32/14.5
37/16.9
40/18.1
45/20.4
Reflector Weight
3/1.4
3/1.4
3/1.4
3/1.4
Guard Weight
1/.5
1/.5
2/.9
2/.9
Pendant
2/0.9
Ceiling
4/1.8
Bracket
6/2.7
Stanchion
2/0.9
Reflector Dimensions in In/mm
Standard and Deep Dome
30° Angle
High Bay
10.96"/
278.4 mm
10.56"/
268.2 mm
13.30"/
337.8 mm
5.00"/
127 mm
9.75"/
247.7 mm
16.16"/
410.5 mm
20.80"/
528.3 mm
➊ 50, 70, 100 and 150 W HPS; 175 W PSMH; 175 and 250 W MH.
➋ 250 and 400 W HPS; 250, 320, 350 and 400 W PSMH; 400 W MH.
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
1225
Lighting: Explosionproof — Area — HID
5.50"/
139.7 mm
Dimensions in In/mm
Code•Master 2™ HID Factory Sealed Luminaire Photometric Data
Explosionproof, Dust-Ignitionproof
Integrally Ballasted. 50 W, 70 W, 100 W, 150 W, 250 W, 400 W HPS; 175 W, 250 W, 320 W, 350 W, 400 W PSMH; 175 W, 250 W, 400 W MH V.
Mogul Base. For use with threaded metal conduit.
* Photometric data is based on a 100watt clear HPS lamp (9,500 lumens). For
candlepower values of fixtures with other
lamps, use the following multipliers: 50 W HPS
– 0.42 (4,000 lumens); 70 W HPS – 0.61 (6,300
lumens); and 150 W HPS – 1.68 (16,000 lumens).
Total Luminaire Efficiency = 76.4%
CIE Type - Semi-Direct
Plane
Spacing
Criteria
0-180
2.66
90-270
2.66
Diagonal
2.84
REPORT NUMBER: CL10G
Lamps: 100 W High Pressure Sodium with Globe only
Coefficients of Utilization - Zonal Cavity Method
Effective Floor Cavity Reflectance 0.20
% Ceiling Rcc
Lighting: Explosionproof — Area — HID
Lighting
% Walls
Zone
0-10
10-20
20-30
30-40
40-50
50-60
60-70
70-80
80-90
90-100
100-110
Lumens
29.80
106.54
202.92
318.52
468.31
670.49
866.67
976.61
1038.41
1042.18
927.00
110-120
551.82
120-130
130-140
140-150
150-160
160-170
170-180
51.82
2.51
0.25
0.00
0.00
0.00
Total Luminaire Efficiency = 71.3%
CIE Type - Direct
Plane
Spacing
Criteria
0-180
1.54
90-270
1.54
Diagonal
1.66
0
1
2
3
4
5
6
7
8
9
10
Lumens
40.00
331.02
660.22
934.51
1131.33
1272.76
1322.68
826.95
254.44
0.00
0.00
110-120
0.00
120-130
130-140
140-150
150-160
160-170
170-180
0.00
0.00
0.00
0.00
0.00
0.00
1226
70
50
30
10
0
70 50 30 10
70 50 30 10
50 30 10
50 30 10
50 30 10
0
84
72
63
56
51
46
42
39
36
33
31
79
66
58
52
47
42
39
36
33
31
29
70
53
43
36
31
28
24
22
20
18
17
61
45
37
31
26
23
21
18
17
15
14
53
38
30
25
22
19
17
15
14
13
12
84
66
54
46
40
35
31
28
25
23
21
84
61
47
38
32
27
23
20
18
16
14
84
56
41
32
26
21
18
15
13
11
10
79
61
51
43
37
32
29
26
23
21
19
79
57
44
36
30
25
22
19
17
15
13
79
52
39
30
24
20
17
14
12
11
9
70
49
38
31
25
22
19
16
14
13
12
70
46
34
26
21
17
14
12
10
9
8
61
42
32
26
22
18
16
14
12
11
10
61
40
29
22
18
14
12
10
9
8
7
53
36
27
22
18
15
13
11
10
9
8
53
34
24
18
14
12
10
8
7
6
6
49
30
21
15
12
9
7
6
5
4
4
Zonal Lumen Summary
Zone
0-30
0-40
0-60
0-90
Lumens
339.26
657.79
1796.59
4678.28
% Lamp
3.6
6.9
18.9
49.2
% Fixture
4.7
9.1
24.8
64.5
Zone
90-120
90-130
90-150
90-180
0-180
Lumens
2521.83
2572.83
2575.59
2575.59
7253.87
% Lamp
26.5
27.1
27.1
27.1
76.4
% Fixture
34.8
35.5
35.5
35.5
100.0
REPORT NUMBER: CL10ST
Lamps: 100 W High Pressure Sodium with Standard Dome Reflector
Coefficients of Utilization - Zonal Cavity Method
Effective Floor Cavity Reflectance 0.20
% Ceiling Rcc
% Walls
Zone
0-10
10-20
20-30
30-40
40-50
50-60
60-70
70-80
80-90
90-100
100-110
Rw
80
Rw
0
1
2
3
4
5
6
7
8
9
10
80
70
50
30
10
0
70 50 30 10
70 50 30 10
50 30 10
50 30 10
50 30 10
0
85
76
67
60
54
49
45
41
38
35
33
83
74
65
58
52
48
43
40
37
34
32
79
67
56
48
41
36
32
29
26
24
22
76
64
54
46
40
35
31
28
25
23
21
73
61
51
44
38
33
30
27
24
22
20
85
71
60
51
44
39
34
30
27
25
23
85
68
54
44
37
31
27
23
21
18
17
85
64
49
39
31
26
22
19
16
14
12
83
70
59
50
43
38
33
30
27
24
22
83
66
53
44
36
31
27
23
20
18
16
83
63
49
38
31
26
22
18
16
14
12
79
64
51
42
35
30
26
23
20
18
16
79
61
47
38
31
25
21
18
16
14
12
76
61
50
41
34
29
25
22
20
18
16
76
59
46
37
30
25
21
18
16
14
12
73
59
48
40
33
29
25
22
19
17
15
73
57
45
36
30
25
21
18
16
14
12
71
56
43
34
28
23
19
16
14
12
11
Zonal Lumen Summary
Zone
0-30
0-40
0-60
0-90
Lumens
1031.23
1965.74
4369.83
6773.90
% Lamp
10.9
20.7
46.0
71.3
% Fixture
15.2
29.0
64.5
100.0
Zone
90-120
90-130
90-150
90-180
0-180
Lumens
0.00
0.00
0.00
0.00
6773.90
% Lamp
0.0
0.0
0.0
0.0
71.3
% Fixture
0.0
0.0
0.0
0.0
100.0
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
Code•Master 2™ HID Factory Sealed Luminaire Photometric Data
Explosionproof, Dust-Ignitionproof
Integrally Ballasted. 50 W, 70 W, 100 W, 150 W, 250 W, 400 W HPS; 175 W, 250 W, 320 W, 350 W, 400 W PSMH; 175 W, 250 W, 400 W MH V.
Mogul Base. For use with threaded metal conduit.
* Photometric data is based on a 100-watt
clear High Pressure Sodium lamp (9,500
lumens). For candlepower values of fixtures
with other lamps, use the following multipliers:
50 W HPS – 0.42 (4,000 lumens); 70 W HPS
– 0.61 (6,300 lumens); and 150 W HPS – 1.68
Total Luminaire Efficiency = 61.9%
CIE Type - Direct
Plane
Spacing
Criteria
0-180
1.96
90-270
1.62
Diagonal
1.50
(16,000 lumens).
REPORT NUMBER: CL10AN
Lamps: 100 W High Pressure Sodium with 30° Angle Dome Reflector
Coefficients of Utilization - Zonal Cavity Method
Effective Floor Cavity Reflectance 0.20
% Ceiling Rcc
% Walls
110-120
0.00
120-130
130-140
140-150
150-160
160-170
170-180
0.00
0.00
0.00
0.00
0.00
0.00
Total Luminaire Efficiency = 37.8%
CIE Type - Direct
Plane
Spacing
Criteria
0-180
1.36
90-270
1.36
Diagonal
1.54
0
1
2
3
4
5
6
7
8
9
10
Lumens
26.07
224.04
437.71
551.18
656.83
743.35
592.81
265.53
94.52
0.00
0.00
110-120
0.00
120-130
130-140
140-150
150-160
160-170
170-180
0.00
0.00
0.00
0.00
0.00
0.00
30
10
0
50 30 10
50 30 10
50 30 10
0
74
64
57
51
47
42
39
36
33
31
29
72
62
55
50
45
41
38
35
32
30
28
69
56
47
40
35
31
28
25
22
20
19
66
53
45
38
34
30
26
24
22
20
18
63
51
43
37
32
28
25
23
21
19
18
74
60
51
43
38
33
29
26
24
22
20
74
56
45
37
31
27
23
20
18
16
14
74
53
41
32
26
22
19
16
14
12
11
72
59
49
42
37
32
29
26
23
21
19
72
55
44
37
31
26
23
20
18
16
14
72
52
40
32
26
22
18
16
14
12
11
69
53
43
35
30
26
22
20
17
15
14
69
50
39
31
26
21
18
16
14
12
11
66
51
41
34
29
25
22
19
17
15
14
66
49
38
31
25
21
18
16
14
12
11
63
49
40
33
28
24
21
19
17
15
13
63
47
37
30
25
21
18
15
13
12
11
62
46
36
28
23
19
16
14
12
11
9
Zonal Lumen Summary
Zone
0-30
0-40
0-60
0-90
Lumens
911.80
1737.18
3634.06
5883.18
% Lamp
9.6
18.3
38.3
61.9
% Fixture
15.5
29.5
61.8
100.0
Zone
90-120
90-130
90-150
90-180
0-180
Lumens
0.0
0.0
0.0
0.0
5883.18
% Lamp
0.0
0.0
0.0
0.0
61.9
% Fixture
0.0
0.0
0.0
0.0
100.0
REPORT NUMBER: CL10DD
Lamps: 100 W High Pressure Sodium with Deep Dome Reflector
Coefficients of Utilization - Zonal Cavity Method
Effective Floor Cavity Reflectance 0.20
% Ceiling Rcc
% Walls
Zone
0-10
10-20
20-30
30-40
40-50
50-60
60-70
70-80
80-90
90-100
100-110
50
70 50 30 10
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
Rw
0
1
2
3
4
5
6
7
8
9
10
80
70
50
30
10
0
70 50 30 10
70 50 30 10
50 30 10
50 30 10
50 30 10
0
45
41
37
33
30
27
25
23
21
20
18
44
40
36
32
29
26
24
22
21
19
18
42
36
31
27
23
21
18
16
15
13
12
40
35
30
26
22
20
18
16
14
13
12
39
33
29
25
22
19
17
15
14
13
12
45
39
33
29
25
22
19
17
16
14
13
45
37
30
25
21
18
16
14
12
11
10
45
35
28
22
18
15
13
11
10
9
8
44
38
32
28
24
21
19
17
15
14
13
44
36
30
25
21
18
16
14
12
11
10
44
35
28
22
18
15
13
11
10
9
8
42
35
29
24
20
17
15
13
12
11
10
42
34
27
22
18
15
13
11
10
9
8
40
34
28
23
20
17
15
13
12
10
9
40
33
26
21
18
15
13
11
10
8
8
39
32
27
23
19
17
15
13
11
10
9
39
32
26
21
18
15
13
11
10
8
7
38
31
25
20
17
14
12
10
9
8
7
Zonal Lumen Summary
Zone
0-30
0-40
0-60
0-90
Lumens
687.82
1239.00
2639.18
3592.04
% Lamp
7.2
13.0
27.8
37.8
% Fixture
19.1
34.5
73.5
100.0
Zone
90-120
90-130
90-150
90-180
0-180
Lumens
0.0
0.0
0.0
0.0
3592.04
% Lamp
0.0
0.0
0.0
0.0
37.8
% Fixture
0.0
0.0
0.0
0.0
100.0
1227
Lighting: Explosionproof — Area — HID
Lumens
34.59
289.50
587.71
825.38
944.04
952.84
900.69
740.88
607.55
0.00
0.00
70
70 50 30 10
Lighting
Zone
0-10
10-20
20-30
30-40
40-50
50-60
60-70
70-80
80-90
90-100
100-110
Rw
80
Code•Master 2™ HID Factory Sealed Luminaire Photometric Data
Explosionproof, Dust-Ignitionproof
Integrally Ballasted. 50 W, 70 W, 100 W, 150 W, 250 W, 400 W HPS; 175 W, 250 W, 320 W, 350 W, 400 W PSMH; 175 W, 250 W, 400 W MH V.
Mogul Base. For use with threaded metal conduit.
* Photometric data is based on a 400-watt
clear Pulse Start Metal Halide lamp (34,000
lumens). For candlepower values of fixtures
with other lamps, use the following multipliers:
400 W HPS – 1.13 (50,000 lumens); and 250 W
HPS – 0.68 (30,000 lumens).
Total Luminaire Efficiency = 81.9%
CIE Type - General Diffuse
REPORT NUMBER: CP40G
Lamps: 400 W Pulse Start Metal Halide with Globe only
Coefficients of Utilization - Zonal Cavity Method
Effective Floor Cavity Reflectance 0.20
% Ceiling Rcc
Lighting: Explosionproof — Area — HID
Lighting
% Walls
Zone
0-10
10-20
20-30
30-40
40-50
50-60
60-70
70-80
80-90
90-100
100-110
110-120
Lumens
161.29
470.38
918.96
1511.24
2242.10
3052.29
3653.41
4255.87
4603.15
4476.83
4007.91
3380.83
120-130
130-140
140-150
150-160
160-170
170-180
2599.55
672.85
18.11
2.59
1.21
0.65
Total Luminaire Efficiency = 70.4%
CIE Type - Direct
Plane
Spacing
Criteria
0-180
1.46
90-270
1.46
Diagonal
1.70
Lumens
595.04
1709.44
2776.90
3730.18
4573.20
5290.95
5418.07
5086.12
1757.09
33.71
0.00
0.00
120-130
0.00
130-140
140-150
150-160
160-170
170-180
0.00
0.00
0.00
0.00
0.00
1228
70
50
30
10
0
Rw
70 50 30 10
70 50 30 10
50 30 10
50 30 10
50 30 10
0
0
1
2
3
4
5
6
7
8
9
10
89
76
67
60
55
50
45
42
39
36
33
83
70
62
55
50
45
41
38
35
33
31
72
55
45
39
33
29
26
23
21
19
18
61
46
37
32
27
24
21
19
17
16
15
52
38
30
25
22
19
17
15
14
13
12
89
70
59
50
43
38
34
30
27
25
22
89
65
51
42
35
30
26
22
20
18
16
89
60
45
36
29
24
20
17
15
13
11
83
65
54
46
40
35
31
28
25
23
21
83
60
48
39
32
28
24
21
18
16
15
83
56
42
33
27
22
18
16
14
12
10
72
51
40
33
27
23
20
18
15
14
12
72
48
36
28
23
19
16
13
12
10
9
61
43
33
27
22
19
16
14
13
11
10
61
40
30
23
19
15
13
11
9
8
7
52
35
27
22
18
15
13
11
10
9
8
52
33
24
19
15
12
10
9
7
6
6
47
29
20
15
12
9
8
6
5
5
4
Zonal Lumen Summary
Zone
0-30
0-40
0-60
0-90
Lumens
% Lamp
1550.63
3.5
3061.87
7.0
8356.25
19.0
20868.68
47.4
% Fixture
4.3
8.5
23.2
57.9
Zone
90-120
90-130
90-150
90-180
0-180
Lumens
11865.57
14465.12
15156.08
15160.53
36029.22
% Lamp
27.0
32.9
34.4
34.5
81.9
% Fixture
32.9
40.1
40.1
42.1
100.0
REPORT NUMBER: CP40ST
Lamps: 400 W Pulse Start Metal Halide with Standard Dome Reflector
Coefficients of Utilization - Zonal Cavity Method
Effective Floor Cavity Reflectance 0.20
% Ceiling Rcc
% Walls
Zone
0-10
10-20
20-30
30-40
40-50
50-60
60-70
70-80
80-90
90-100
100-110
110-120
80
80
70
50
30
10
0
Rw
70 50 30 10
70 50 30 10
50 30 10
50 30 10
50 30 10
0
0
1
2
3
4
5
6
7
8
9
10
84
74
65
58
53
48
44
41
38
35
33
82
72
63
57
51
46
43
39
37
34
32
78
64
54
46
40
35
31
28
26
23
22
75
62
51
44
38
34
30
27
25
23
21
72
59
49
42
36
32
29
26
24
22
20
84
69
58
49
43
38
33
30
27
25
23
84
65
52
42
35
30
26
23
21
18
17
84
62
47
37
30
25
21
18
16
14
13
82
68
57
48
42
37
33
29
27
24
22
82
64
51
42
35
30
26
23
20
18
17
82
60
46
36
30
25
21
18
16
14
13
78
61
49
40
34
29
25
22
20
18
16
78
58
45
36
29
24
21
18
16
14
13
75
59
47
39
33
28
25
22
19
18
16
75
57
44
35
29
24
21
18
16
14
12
72
57
46
38
32
27
24
21
19
17
16
72
55
43
34
28
24
20
18
15
14
12
70
53
41
32
26
22
19
16
14
12
11
Zonal Lumen Summary
Zone
0-30
0-40
0-60
0-90
Lumens
% Lamp
5081.38
11.5
8811.56
20.0
18675.71
42.4
30936.99
70.3
% Fixture
16.4
28.5
60.3
99.9
Zone
90-120
90-130
90-150
90-180
0-180
Lumens
33.71
33.71
33.71
33.71
30970.7
% Lamp
0.1
0.1
0.1
0.1
70.4
% Fixture
0.1
0.1
0.1
0.1
100.0
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
Code•Master 2™ HID Factory Sealed Luminaire Photometric Data
Explosionproof, Dust-Ignitionproof
Integrally Ballasted. 50 W, 70 W, 100 W, 150 W, 250 W, 400 W HPS; 175 W, 250 W, 320 W, 350 W, 400 W PSMH; 175 W, 250 W, 400 W MH V.
Mogul Base. For use with threaded metal conduit.
* Photometric data is based on a 400-watt
clear Pulse Start Metal Halide lamp (34,000
lumens). For candlepower values of fixtures
with other lamps, use the following multipliers:
400 W HPS – 1.13 (50,000 lumens); and 250 W
HPS – 0.68 (30,000 lumens).
Total Luminaire Efficiency = 62.5%
CIE Type - Direct
Plane
Spacing
Criteria
0-180
2.02
90-270
1.48
Diagonal
1.64
REPORT NUMBER: CP40AN
Lamps: 400 W Pulse Start Metal Halide with 30° Angle Dome Reflector
Coefficients of Utilization - Zonal Cavity Method
Effective Floor Cavity Reflectance 0.20
% Ceiling Rcc
% Walls
120-130
65.68
130-140
140-150
150-160
160-170
170-180
20.81
11.94
7.93
4.46
1.47
Total Luminaire Efficiency = 69.1%
CIE Type - Direct
Plane
Spacing
Criteria
0-180
1.48
90-270
1.48
Diagonal
1.62
Lumens
676.92
1962.51
3199.12
4281.42
4889.12
5408.09
5456.18
3822.90
693.25
20.14
0.00
0.00
120-130
130-140
140-150
150-160
160-170
170-180
0.00
0.00
0.00
0.00
0.00
0.00
30
10
0
70 50 30 10
50 30 10
50 30 10
50 30 10
0
0
1
2
3
4
5
6
7
8
9
10
73
64
57
51
47
43
39
36
34
31
29
71
62
55
49
45
41
38
35
32
30
28
67
54
46
39
35
31
27
25
22
21
19
63
51
43
37
32
29
26
23
21
20
18
59
48
40
35
30
27
24
22
20
19
17
73
60
51
44
38
34
30
27
24
22
20
73
56
45
38
32
27
24
21
19
17
15
73
53
41
33
27
23
19
17
15
13
12
71
58
49
42
37
33
29
26
24
22
20
71
55
44
37
31
27
23
21
18
16
15
71
52
40
32
26
22
19
17
15
13
12
67
52
42
35
29
25
22
20
18
16
14
67
49
38
31
25
22
18
16
14
13
11
63
49
40
33
28
24
21
19
17
15
14
63
47
37
30
25
21
18
16
14
12
11
59
46
38
31
27
23
20
18
16
15
13
59
44
35
26
24
20
17
15
13
12
11
58
42
33
27
22
19
16
14
12
11
10
Zonal Lumen Summary
Zone
0-30
0-40
0-60
0-90
Lumens
% Lamp
4398.28
10.0
7751.71
17.6
15573.61
35.4
25338.08
57.6
% Fixture
16.0
28.2
56.7
92.2
Zone
90-120
90-130
90-150
90-180
0-180
Lumens
2039.87
2105.55
2138.30
2152.16
27490.24
% Lamp
4.6
4.8
4.9
4.9
62.5
% Fixture
7.4
7.7
7.7
7.8
100.0
REPORT NUMBER: CP40DD
Lamps: 400 W Pulse Start Metal Halide with Deep Dome Reflector
Coefficients of Utilization - Zonal Cavity Method
Effective Floor Cavity Reflectance 0.20
% Ceiling Rcc
% Walls
Zone
0-10
10-20
20-30
30-40
40-50
50-60
60-70
70-80
80-90
90-100
100-110
110-120
50
70 50 30 10
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
80
70
50
30
10
0
Rw
70 50 30 10
70 50 30 10
50 30 10
50 30 10
50 30 10
0
0
1
2
3
4
5
6
7
8
9
10
82
74
66
59
54
49
45
41
38
36
34
80
72
64
57
52
47
44
40
37
35
33
77
65
55
48
42
37
33
30
27
25
23
73
63
53
46
40
35
32
29
26
24
22
70
60
51
44
38
34
30
28
25
23
21
82
70
59
51
44
39
35
31
28
26
24
82
66
54
44
38
32
28
24
22
20
18
82
63
49
39
32
27
23
20
18
16
14
80
68
58
50
43
38
34
31
28
25
23
80
65
53
44
37
32
28
24
22
20
18
80
62
49
39
32
27
23
20
18
16
14
77
63
51
42
36
31
27
24
21
19
18
77
60
47
38
32
27
23
20
17
16
14
73
60
49
41
35
30
26
23
21
19
17
73
58
46
38
31
26
23
20
17
15
14
70
58
48
40
34
29
26
23
21
19
17
70
57
45
37
31
26
22
19
17
15
14
69
55
44
35
29
24
21
18
16
14
12
Zonal Lumen Summary
Zone
0-30
0-40
0-60
0-90
Lumens
% Lamp
5838.56
13.3
10119.98
23.0
20417.19
46.4
30389.51
69.1
% Fixture
19.2
33.3
67.1
99.9
Zone
90-120
90-130
90-150
90-180
0-180
Lumens
20.14
20.14
20.14
20.14
30409.65
% Lamp
0.0
0.0
0.0
0.0
69.1
% Fixture
0.1
0.1
0.1
0.1
100.0
1229
Lighting: Explosionproof — Area — HID
Lumens
503.08
1461.14
2434.06
3353.43
3867.50
3954.40
3752.38
3368.71
2643.39
1531.50
421.63
86.74
70
Rw
Lighting
Zone
0-10
10-20
20-30
30-40
40-50
50-60
60-70
70-80
80-90
90-100
100-110
110-120
80
Code•Master 2™ HID Factory Sealed Luminaire Photometric Data
Explosionproof, Dust-Ignitionproof
Integrally Ballasted. 50 W, 70 W, 100 W, 150 W, 250 W, 400 W HPS; 175 W, 250 W, 320 W, 350 W, 400 W PSMH; 175 W, 250 W, 400 W MH V.
Mogul Base. For use with threaded metal conduit.
* Photometric data is based on a 400-watt
clear Pulse Start Metal Halide lamp (34,000
lumens). For candlepower values of fixtures
with other lamps, use the following multipliers:
400 W HPS – 1.13 (50,000 lumens); and 250 W
HPS – 0.68 (30,000 lumens).
Total Luminaire Efficiency = 63.4%
CIE Type - Direct
Plane
Spacing
Criteria
0-180
1.40
90-270
1.40
Diagonal
1.52
REPORT NUMBER: CP40HB
Lamps: 400 W Pulse Start Metal Halide with High Bay Reflector
Coefficients of Utilization - Zonal Cavity Method
Effective Floor Cavity Reflectance 0.20
% Ceiling Rcc
% Walls
Zone
Lighting: Explosionproof — Area — HID
Lighting
0-10
Rw
80
70
50
30
10
0
70 50 30 10
70 50 30 10
50 30 10
50 30 10
50 30 10
0
Lumens
0
76 76 76 76 74 74 74 74 70 70 70 67 67 67 65 65 65 63
1044.42
1
71 69 67 65 69 67 65 64 65 63 62 62 61 60 60 59 58 57
10-20
3491.70
2
66 62 59 56 64 61 58 55 59 56 54 57 55 53 55 53 52 50
20-30
5976.88
3
61 56 52 48 60 55 51 48 53 50 47 51 49 46 50 48 46 44
30-40
6632.58
4
57 50 46 42 55 50 45 42 48 44 42 47 44 41 45 43 40 39
40-50
7143.25
5
53 46 41 37 51 45 40 37 44 40 37 43 39 36 42 38 36 35
50-60
2844.46
6
49 42 37 33 48 41 36 33 40 36 33 39 35 32 38 35 32 31
60-70
634.65
7
46 38 33 30 44 37 33 29 37 32 29 36 32 29 35 31 29 28
70-80
115.54
8
42 35 30 27 42 34 30 26 34 29 26 33 29 26 32 29 26 25
80-90
20.82
9
40 32 27 24 39 32 27 24 31 27 24 30 26 24 30 26 24 23
10
37 29 25 22 36 29 25 22 29 24 22 28 24 22 27 24 21 20
90-100
1.23
100-110
0.00
110-120
0.00
Zonal Lumen Summary
120-130
0.00
Zone
Lumens
% Lamp
130-140
0.00
0-30
10513.00
23.9
37.7
90-120
1.23
0.0
0.0
140-150
0.00
0-40
17145.58
39.0
61.4
90-130
1.23
0.0
0.0
150-160
0.00
0-60
27133.29
61.7
97.2
90-150
1.23
0.0
0.0
160-170
0.00
0-90
27904.30
63.4
100.0
90-180
1.23
0.0
0.0
170-180
0.00
27905.53
63.4
100.0
1230
% Fixture
Zone
0-180
Lumens
% Lamp
% Fixture
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
Code•Master 2™ Induction Lighting System
Explosionproof, Factory Sealed
Class I, Division 1 and 2, Groups C, D
Class II, Division 1 and 2, Groups E, F, G
Marine Type Electric Fixtures
Outside Type (Salt Water)
NEMA 4X
Applications
• Ideal for where access to relamp is difficult, reliability is
essential and environment is costly to maintain. Also for
cold-environment applications.
• Code Master Induction fixtures are ideal for: use in chemical
and petrochemical plants, such as manufacturers of plastics,
paints and thinners; in refineries; and in other process areas
where ignitable vapors, moisture and corrosive elements
may be present.
• Suitable for use in wet locations.
Features
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
Standard Materials
• Fixture bodies and guards: copperfree (4/10 of 1% max.)
aluminum.
• Pendant mounting hoods: diecast copperfree (4/10 of 1% max.)
aluminum.
• Ceiling, bracket and stanchion mounting hoods: sand-cast
copperfree (4/10 of 1% max.) aluminum.
• Reflectors: aluminum or fiberglass reinforced polyester.
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
Standard Finishes
• Fixture bodies, guards and mounting hoods: epoxy powder
coat finish, electrostatically applied for complete, uniform
corrosion protection.
Options
• Fuses can be ordered for field installation by catalog number.
Certifications and Compliances
• UL Standard: UL 1598, UL 1598A, UL 844
• UL Listed: E10444
1231
Lighting: Explosionproof — Area — Induction
•
•
•
Illustrated Features
Lighting
•
Instant start and restrike.
High lumen output and efficacy (up to 73 lumens per watt).
Fixtures operate safely in a 104 °F/40 °C ambient.
Good lumen maintenance provides less than 30% depreciation
after 60,000 hours of operation.
Virtually maintenance free.
Ultra-long 100,000 hours of life keeps maintenance costs
to a minimum.
Starts in temperatures as low as -40 °F/-40 °C.
Arrangement of heat-producing components results in more
efficient heat dissipation for cooler fixture operation.
Patented “wireless” design. Threading of fixture unit onto
mounting hood makes electrical connection. Only wiring
required is attaching two wires to connection block in
mounting hood.
Connection block is easily wired: (a) loosen two screws; (b)
make wire connections; and (c) reposition connection block
and tighten screws.
Low total harmonic distortion (<10%).
No cycling at end of life.
Acme double lead threads speed installation and fixture
removal from mounting hood – only half as many turns are
required as for single lead threads. The threads do not stick or
gall, eliminating the troublesome problems often encountered
with single lead threads during fixture unit removal.
All threaded joints are flame-tight.
Factory sealed. External seals not required.
Strategic location of lamp socket in combination with the
interior prism design of the glass globe, provides optimum light
distribution and control.
Superior corrosion resistance, with epoxy powder coat finish.
Choice of mountings: pendant, ceiling, bracket or stanchion.
Fiberglass-reinforced polyester reflectors, in standard
dome, deep dome or 30° angle, are ideal in installations
where luminaire is subject to exceptionally severe corrosive
atmospheres. The high bay aluminum reflector is designed
for installations where mounting height work planes range
from 20 to 30 feet/6 to 9 meters
Optional guards protect globes from damage. Secured to
fixture with three screws.
Code•Master 2™ Induction Lighting System Classified Area and Ambient Suitability
Explosionproof, Factory Sealed
Class I, Division 1 and 2, Groups C, D
Class II, Division 1 and 2, Groups E, F, G
Marine Type Electric Fixtures
Outside Type (Salt Water)
NEMA 4X
Classified Area Suitability of Code•Master 2 Series Induction Fixtures (suitability includes use of reflector)
Induction
Class II, Division 1 & 2
With Globe or with Globe & Reflector
NEC/cUL/CEC Temp. Ident. No.
Watts
Supply Wire
Temp
°F/°C
Ambient
Temp
°F/°C
Nameplate Marking
Groups
Nameplate Marking
Groups
55
140/60
104/40
T6
C,D
T6
E,F,G
85
167/75
104/40
T6
C,D
T6
E,F,G
Lamps
Type
Class I, Division 1 & 2
With Globe or with Globe & Reflector
NEC/cUL/CEC Temp. Ident. No.
NOTE: The maximum operating temperature of the fixture must not exceed the ignition temperature of the gas, vapor or dust to be encountered per the
National Electrical Code.
“T”
Number
T1
350
325
T2
T2A
T2B
T2C
T2D
T3
T3A
T3B
T3C
T4
T4A
T5
T6
Temp.
Range
(°F)
664842
619662
574617
538572
502536
448500
421446
394419
358392
331356
322329
277320
250275
214248
187212
185
Temp.
Range
(°˚C)
351450
326350
301325
281300
261280
231260
216230
201215
181200
166180
161165
136160
121135
101120
86-100
85
Lighting: Explosionproof — Area — Induction
Lighting
“T” Numbers Represent the Maximum Surface Temperature for Class I, Division 1 Locations and
Maximum Surface Temperature Under Dust Blanket for Class II, Division 1 Locations.
1232
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
Code•Master 2™ Induction Lighting System
Explosionproof, Factory Sealed
55 W and 85 W
Class I, Division 1 and 2, Groups C, D
Class II, Division 1 and 2, Groups E, F, G
Marine Type Electric Fixtures
Outside Type (Salt Water)
NEMA 4X
Type
Mounting
Lamp
Watts
Hub Size
(Inches)
Catalog
Number ➊
55
3/4
CQP5575 ➋
55
1
CQP5510 ➋
85
3/4
CQP8575 ➋
85
1
CQP8510 ➋
55
3/4
CQC5575 ➋
55
1
CQC5510 ➋
85
3/4
CQC8575 ➋
85
1
CQC8510 ➋
55
3/4
CQB5575 ➋
55
1
CQB5510 ➋
85
3/4
CQB8575 ➋
85
1
CQB8510 ➋
55
1-1/4 or 1-1/2 ➌
CQS55150 ➋
85
1-1/4 or 1-1/2 ➌
CQS85150 ➋
Pendant
One Hub,
Rigid or Flexible
Mounting
Ceiling
Four Hubs,
Three Close-up Plugs
Lighting
Bracket
Four Hubs,
Three Close-up Plugs
Lighting: Explosionproof — Area — Induction
25° Stanchion ➍
One Hub
➊ To order fixture with guard, add suffix G (before adding voltage suffix).
➋ Add voltage suffix 120 for 90-140 Vac; or 277 for 180-305 Vac.
➌ 1-1/2” tapped hub furnished with 1-1/2” to 1-1/4” reducer.
➍ Refer to lamp manufacturer’s data regarding lamp burning position restrictions.
Shaded items are suitable for Class I, Group C in addition to other applicable area suitabilities.
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
1233
Code•Master 2™ Induction Lighting System Accessories
Explosionproof, Factory Sealed
Class I, Division 1 and 2, Groups C, D
Class II, Division 1 and 2, Groups E, F, G
Marine Type Electric Fixtures
Outside Type (Salt Water)
NEMA 4X
Mounting Hoods
Hub Size
(Inches)
Type Mounting
Catalog Number
Pendant
3/4
CAP-75
1
CAP-100
Four Hubs,
Three Close-Up Plugs
3/4
CAC-75
1
CAC-100
Four Hubs,
Three Close-Up Plugs
3/4
CALB-75
1
CALB-100
One Hub
Ceiling
Bracket
25˚ Stanchion
Lighting: Explosionproof — Area — Induction
Lighting
One Hub
CAS-150
1-1/4 or 1-1/2 ➊
Mounting Adapter with Connection Block
Permits use of existing A-51 mounting hoods (AAC Ceiling or AALB
Bracket) with the new Code•Master 2 Fixture Unit. After removing
existing Fixture Unit and adapter, screw in the new CMAD-1 Adapter.
Then thread new Fixture Unit into the CMAD-1.
CMAD-1
Fixture Units — 55 W to 85 W
Fixture body with globe. Indicate voltage desired by adding voltage suffix to Fixture Unit catalog
number listed below.
Type
Frequency
120 V
277 V
Induction
50/60 Hz
55
CMBQ55
-12
-27
50/60 Hz
85
CMBQ85
-12
-27
Fixture and Accessory Weights lbs/kgs
Fixture Unit
Number
Add Voltage Suffixes
Lamp
Watts
Mounting Hood Weights lbs/kgs
Fixture Size
Fixture Weight
Reflector
Weight
Guard
Weight
55 W
28/12.7
3/1.4
1/.5
Pendant
Ceiling
Bracket
Stanchion
2/.9
4/1.8
6/2.7
2/.9
85 W
28/12.7
3/1.4
1/.5
➊ 1-1/2” Tapped hub furnished with 1-1/2” to 1-1/4” reducer.
Shaded items are suitable for Class I, Group C in addition to other applicable area suitabilities.
1234
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
Code•Master 2™ Induction Lighting System Accessories
Explosionproof, Factory Sealed
Description
Catalog Number
Polyester Reflectors — 55 W and 85 W
Standard Dome
CMR-4ST
Deep Dome
CMR-4DD
30˚ Angle
CMR-4AN
55 W and 85 W
CMR-4HB
55 W and 85 W
CGL-400
Aluminum High Bay Reflectors
Prismatic Glass Globes
Lighting
Aluminum Guards
CGU4
Lighting: Explosionproof — Area — Induction
Connection Block
VPT-7
55 W and 85 W
For all Code•Master 2 Induction fixtures
Lamp
Watts
Volts
Fuse Quantity Required
Fuse Catalog Number
55
120-277
See note below ➊
CF2
85
120-277
See note below ➊
CF2
Fuse Kit includes fuse, fuse holder and necessary hardware for field installation. Mounts easily in ballast body with one screw.
➊ Order one fuse for 120 and 277 V, and 2 fuses for 208 and 240 V.
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
1235
Code•Master 2™ Induction Lighting System Operating Data
Explosionproof, Factory Sealed
Electromagnetic Compatibility
A.) Complies with European norms EN55015, EN6100-3-2 and EN61547
B.) RFI
a.) Meets standard EN55022 and is valid for frequencies up to 1000 MHz.
Lighting: Explosionproof — Area — Induction
Lighting
Electrical Characteristics
System power ➊ nom.
System power ➊ min.
System power ➊ max.
AC supply voltage nom.
AC supply voltage min.
AC supply voltage max.
DC supply voltage nom.
DC supply voltage min.
DC supply voltage max.
Supply frequency nom.
Supply frequency min.
Supply frequency max.
Supply current nom.
Inrush current max.
Duration inrush current max.
Power factor nom.
HF output frequency nom.
HF output frequency min.
HF output frequency max.
HF output voltage max.
Leakage current
Overvoltage
55 W
100-120 V
55
53.1
56.9
120
90
140
120
90
180
60
47
63
460
16
170
>0.92
2.65
2.30
3.00
1.5
<0.5
200 Vac
W
W
W
V
V
V
V
V
V
Hz
Hz
Hz
mA
A
usec
MHz
MHz
MHz
kV
mA
55 W
200-277 V
55
53.1
56.9
230
180
305
230
180
350
50
47
63
260
12
170
>0.92
2.65
2.30
3.00
1.5
<0.5
400 Vac
85 W
100-120 V
85
82.0
88.0
120
90
140
120
90
180
60
47
63
730
16
170
>0.92
2.65
2.30
3.00
1.5
<0.5
200 Vac
85 W
200-277 V
85
82.0
88.0
230
180
305
230
180
350
50
47
63
400
12
170
>0.92
2.65
2.30
3.00
1.5
<0.5
400 Vac
Lamp Characteristics
Values at 100 hours
Luminous flux nom.
Luminous flux min.
Luminous flux max.
System efficacy nom.
lm
lm
lm
lm/W
QL 55 W
QL 85 W
3500
3200
3800
65
6000
5500
6500
70
Lamp Operation
A.) Ignition and Lifetime Performance
a.) Ignition time <0.5 second
Hot Restrike time <0.5 second
b.) Induction lighting offers a direct, flicker-free ignition after switch-on, in both cold and hot conditions
B.) Lumen Maintenance
a.)The lumens of an induction lamp are expected to have depreciated after 60,000 hours to no less than 75% of the initial lumens
➊ At design voltage.
1236
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
Code•Master 2™ Induction Lighting System Photometric Data
Explosionproof, Factory Sealed
Data based on fixtures with 85-watt lamp.
For candlepower values of fixtures with other
lamps, use the following multiplier: for 55 W
lamp – 0.59 (3,500 lumens).
Total Luminaire Efficiency = 71.6%
Report Number: CMBQL85
85-Watt Lamp with Globe only
CIE Type - Semi-Direct
Degree
Candela
Lumens
Coefficients of Utilization - Zonal Cavity Method
Effective Floor Cavity Reflectance (Rfc) = 0.20
0
301
5
304
29
% Ceiling Rc
15
318
91
% Walls
80
70
50
30
10
0
Rw 70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10
0
25
359
166
0 79 79 79 79 74 74 74 74 65 65 65 57 57 57 49 49 49 46
35
398
250
1 68 63 58 54 63 59 55 51 51 48 45 44 41 39 37 35 33 30
45
424
328
2 60 53 46 41 56 49 43 39 42 38 34 36 32 29 30 27 25 22
55
447
400
3 54 45 38 32 50 42 36 30 36 31 27 30 26 23 25 22 19 16
65
465
462
4 49 39 32 26 45 36 30 25 31 26 22 26 22 19 22 18 16 13
75
475
502
5 45 34 27 22 41 32 25 21 27 22 18 23 19 15 19 16 13 11
85
474
517
90
472
Zonal Lumen Summary
Zone
Lumens % Lamp % Fixture
468
510
440
464
0- 30
115
125
135
145
155
165
175
180
348
205
58
2
1
1
0
0
344
185
49
2
0
0
0
0- 40
0- 60
0- 90
90-120
90-130
90-150
90-180
0-180
287
4.8
6.7
537
1265
2745
1318
1503
1553
1553
4298
8.9
21.1
45.7
22.0
25.0
25.9
25.9
71.6
12.5
29.4
63.9
30.6
35.0
36.1
36.1
100.0
Total Luminaire Efficiency = 62.9%
8
6
9
13 10
7
6
8
12
6
5
Rw 70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10
0
10 30 20 15 11 28 19 14 10 17 12
9
14 10
9
Lumens
Coefficients of Utilization - Zonal Cavity Method
Effective Floor Cavity Reflectance (Rfc) = 0.20
0
960
5
962
92
15
955
271
% Ceiling Rc
% Walls
80
70
50
30
10
0
25
942
436
0 75 75 75 75 73 73 73 73 69 69 69 66 66 66 63 63 63 62
35
903
566
1 67 64 61 58 66 63 60 57 60 58 55 57 55 54 55 53 52 50
45
834
647
2 61 55 50 46 59 54 49 46 51 48 44 49 46 43 47 44 42 41
55
764
683
3 55 48 42 38 53 46 41 37 44 40 36 43 39 36 41 38 35 33
65
611
600
4 50 42 36 31 48 41 35 31 39 34 30 37 33 30 36 32 29 28
75
325
346
5 45 37 31 26 44 36 30 26 35 30 26 33 29 25 32 28 25 24
89
85
76
90
14
6 42 33 27 23 40 32 27 22 31 26 22 30 25 22 29 25 22 20
Zonal Lumen Summary
Zone
95
10
11
105
8
10
0-30
115
125
135
145
155
165
175
180
11
11
6
1
1
0
1
0
10
9
5
1
0
0
0
0-40
0-60
0-90
90-120
90-130
90-150
90-180
0-180
7 39 30 24 20 37 29 23 20 28 23 19 27 22 19 26 22 19 18
Lumens % Lamp % Fixture
8 36 27 21 17 35 26 21 17 25 21 17 25 20 17 24 20 17 15
798
13.3
21.1
9 33 25 19 15 32 24 19 15 23 19 15 23 18 15 22 18 15 14
1364
2694
3729
31
40
46
46
3775
22.7
44.9
62.2
0.5
0.7
0.8
0.8
62.9
36.1
71.4
98.8
0.8
1.1
1.2
1.2
100.0
10 31 23 17 14 30 22 17 14 21 17 14 21 17 14 20 16 13 12
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
1237
Lighting: Explosionproof — Area — Induction
Candela
8 35 25 18 14 32 23 17 13 20 15 11 17 13 10 14 11
9 32 22 16 12 30 21 15 11 18 13 10 15 11
Report Number: CMBQL85ST
85-Watt Lamp with Standard Dome Reflector
CIE Type - Direct
Degree
9
7
9
Lighting
95
105
6 41 30 23 19 38 28 22 17 24 19 15 21 16 13 17 14 11
7 38 27 21 16 35 25 19 15 22 17 13 19 14 11 16 12
Code•Master 2™ Induction Lighting System Photometric Data
Explosionproof, Factory Sealed
Data based on fixtures with 85-watt lamp.
For candlepower values of fixtures with other
lamps, use the following multiplier: for 55 W
lamp – 0.59 (3,500 lumens).
Total Luminaire Efficiency = 56.7%
Report Number: CMBQL85AN
85-Watt Lamp with 30° Angle Dome Polyester Reflector
CIE Type - Direct
Candela Distribution
0.0
Coefficients of Utilization - Zonal Cavity Method
45.0 90.0 135.0 180.0 Flux
Effective Floor Cavity Reflectance (Rfc) = 0.20
% Ceiling Rc
0 842 842 842 842 842
5 881 869 843 814 802
Lighting
70
50
30
10
Rw 70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10
0
0
15 956 920 835 764 738 239
0 67 67 67 67 65 65 65 65 61 61 61 58 58 58 55 55 55 54
25 1015 956 833 728 676 388
1 60 56 53 51 58 55 52 49 52 49 47 49 47 45 46 45 43 42
35 1044 969 822 612 473 494
2 54 48 44 40 52 47 43 39 44 41 38 42 39 37 40 37 35 34
45 1046 960 772 358 198 522
3 48 42 37 33 47 41 36 32 38 34 31 36 33 30 35 32 29 28
55 1030 945 595 137
52 498
4 44 37 31 27 43 36 31 27 34 30 26 32 28 25 31 27 25 23
65 1004 898 349
30
3 441
5 40 33 27 23 39 32 27 23 30 26 22 29 25 22 27 24 21 20
75 932 711 142
2
0 349
6 37 29 24 20 36 29 23 20 27 23 19 26 22 19 25 21 19 17
85 705 425
43
1
1 223
7 34 26 21 17 33 26 21 17 25 20 17 24 20 17 23 19 16 15
90 551 289
11
2
2
8 32 24 19 15 31 23 19 15 22 18 15 22 18 15 21 17 15 13
95 393 177
4
4
4 108
9 30 22 17 14 29 21 17 14 21 16 13 20 16 13 19 16 13 12
105 147
Lighting: Explosionproof — Area — Induction
% Walls
81
80
115
46
61
1
9
6
40
4
3
13
9
13
10 28 20 16 12 27 20 15 12 19 15 12 18 15 12 18 14 12 11
Zonal Lumen Summary
125
2
1
4
12
9
5
Zone
Lumens
135
0
1
2
4
3
2
0- 30
707
% Lamp
11.8
% Fixture
20.8
145
0
1
1
1
1
1
0- 40
1201
20.0
35.3
155
0
1
2
2
1
1
0- 60
2221
37.0
65.3
165
0
1
1
1
0
0
0- 90
3233
53.9
95.0
175
1
1
1
1
0
0
90-120
160
2.7
4.7
180
1
1
1
1
1
90-130
165
2.8
4.9
90-150
168
2.8
4.9
90-180
169
2.8
5.0
0-180
3403
56.7
100.0
1238
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
Code•Master 2™ Induction Lighting System Photometric Data
Data based on fixtures with 85-watt lamp.
For candlepower values of fixtures with other
lamps, use the following multiplier: for 55 W
lamp – 0.59 (3,500 lumens).
Total Luminaire Efficiency = 63.4%
Report Number: CMBQL85DD
85-Watt Lamp with Deep Dome Polyester Reflector
CIE Type - Direct
Degree
Candela
Lumens
Coefficients of Utilization - Zonal Cavity Method
Effective Floor Cavity Reflectance (Rfc) = 0.20
0
1110
5
1109
106
% Ceiling Rc
15
1108
313
% Walls
25
1073
495
0 75 75 75 75 74 74 74 74 70 70 70 67 67 67 64 64 64 63
35
990
620
1 69 66 63 60 67 64 62 59 61 59 57 59 57 55 56 55 54 52
80
70
50
30
10
0
Rw 70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10
0
45
877
679
2 62 57 52 49 60 56 52 48 53 50 47 51 48 46 49 47 45 43
55
788
700
3 56 50 44 40 55 48 44 40 46 42 39 45 41 38 43 40 37 36
65
562
552
4 51 44 38 33 50 43 37 33 41 36 33 39 35 32 38 34 32 30
75
226
245
5 47 39 33 28 46 38 32 28 36 32 28 35 31 28 34 30 27 26
85
48
55
90
12
6 43 35 29 25 42 34 28 24 33 28 24 32 27 24 31 27 24 22
Zonal Lumen Summary
7
8
7
8
115
125
135
145
155
165
175
180
10
11
6
1
1
0
1
0
10
9
5
1
0
0
0
Zone
0-30
0-40
0-60
0-90
90-120
90-130
90-150
90-180
0-180
Lumens % Lamp % Fixture
15.2
24
9 35 26 21 17 34 26 20 17 25 20 17 24 20 17 23 19 17 15
1535
2914
3766
27
35
40
41
3806
25.6
48.6
62.8
0.4
0.6
0.7
0.7
63.4
40.3
76.5
98.9
0.7
0.9
1.1
1.1
100.0
10 32 24 19 15 32 24 19 15 23 18 15 22 18 15 22 18 15 14
Total Luminaire Efficiency = 56.4%
Report Number: CMBQL85HB
85-Watt Lamp with High Bay Aluminum Reflector
CIE Type - Direct
Candela
Lumens
Coefficients of Utilization - Zonal Cavity Method
Effective Floor Cavity Reflectance (Rfc) = 0.20
0
2608
5
2578
244
% Ceiling Rc
15
2261
634
% Walls
80
70
50
30
10
0
Rw 70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10
0
25
1705
784
0 67 67 67 67 65 65 65 65 62 62 62 59 59 59 57 57 57 56
35
1237
774
1 63 61 60 58 62 60 59 57 58 56 55 55 54 54 53 53 52 51
45
770
588
2 59 56 53 51 58 55 52 50 53 51 49 51 49 48 49 48 47 46
55
241
228
3 55 51 48 45 54 50 47 45 49 46 44 47 45 43 46 44 42 41
65
66
69
4 52 47 43 40 51 46 43 40 45 42 39 43 41 39 42 40 38 37
75
15
17
5 49 43 39 36 48 42 39 36 41 38 36 40 37 35 39 37 35 34
85
3
4
90
2
6 46 40 36 33 45 39 35 33 38 35 32 37 34 32 36 34 32 31
Zonal Lumen Summary
7 43 37 33 30 42 36 32 30 35 32 30 35 32 29 34 31 29 28
95
5
5
Zone
105
10
10
0- 30
Lumens % Lamp % Fixture
1662
27.7
49.1
9 38 32 28 25 37 31 28 25 31 27 25 30 27 25 30 27 25 24
115
125
135
145
155
165
175
180
13
12
7
1
0
0
1
1
13
11
5
0
0
0
0
0- 40
0- 60
0- 90
90-120
90-130
90-150
90-180
0-180
2435
3251
3340
29
40
46
46
3386
40.6
54.2
55.7
0.5
0.7
0.8
0.8
56.4
71.9
96.0
98.6
0.9
1.2
1.3
1.4
100.0
10 36 30 26 23 35 29 26 23 29 25 23 28 25 23 28 25 23 22
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
8 40 34 30 27 40 34 30 27 33 30 27 32 29 27 32 29 27 26
1239
Lighting: Explosionproof — Area — Induction
Degree
8 37 28 23 19 36 28 23 19 27 22 19 26 22 19 25 21 18 17
915
Lighting
95
105
7 40 31 26 22 39 31 25 21 30 25 21 29 24 21 28 24 21 19
Code•Master™ PLT Factory Sealed Luminaires
Explosionproof, Dust-Ignitionproof
Integrally Ballasted. 26 W, 32 W, 42 W, 52 W, 64 W, 84 W Compact Fluorescent. For use with Threaded Metal Conduit.
NEC:
Class I, Division 1 and 2, Groups B, C, D
Class II, Division 1 and 2, Groups E, F, G
Class III
NEMA 4X
Suitable for use in wet locations
Exd IIB + H2
Suitable for use in wet locations
CEC: V
Class I, Division 1 and 2, Groups B, C, D
Class I, Zone 1 and 2, Groups IIB + H2 T6
Class II, Division 1 and 2, Groups E, F, G
Class III
CSA 4X
Applications
• For use in hazardous locations such as plants where plastics,
paints, thinners and petrochemicals are manufactured, and in
other areas where ignitable vapors, dust, moisture and corrosive
elements may be present.
• For use in areas where an instant-on white light is desired.
• Suitable for use in wet locations.
• Standard fixtures designed for 26 W, 32 W, 42 W, 52 W (two 26
W), 64 W (two 32 W), and 84 W (two 42 W) PLT lamps.
• Cold weather starting to a minimum temperature of 0 °F/
-18 °C for the Code•Master Jr. PLT and -22 °F/-30 °C for the
Code•Master 2 PLT.
Lighting
Lighting: Explosionproof — Area — Fluorescent
Features
• Fixtures operate safely in high ambient temperatures.
• Arrangement of heat-producing components results in efficient
heat dissipation for cooler fixture operation.
• Patented “wireless” design. Threading of fixture unit onto
mounting hood makes electrical connection. The only
wiring required is attaching two wires to connection block
in mounting hood.
• Connection block is easily wired: (a) loosen two screws; (b)
make wire connections; and (c) reposition connection block.
• Safe, easy servicing without disconnecting any wiring.
“Wireless” fixture unit threads off mounting hood for convenient
servicing or for immediate replacement with a “stand-by” unit.
• Acme double-lead threads speed installation and fixture removal
from mounting hood – only half as many turns are required
as for single-lead threads. The threads do not stick, or gall,
eliminating problems often encountered with single-lead threads
during fixture unit removal.
• All threaded joints are flame-tight.
• Factory sealed. External seals not required for Groups C and D.
• Fixtures for use in Group B locations are furnished complete
with UL required sealing fitting for Code•Master Jr. PLT only.
• Heat- and impact-resistant globes have smooth
dust-resistant exterior.
• Superior corrosion resistance, with epoxy powder coat finish.
• Fluorescent light source reduces energy cost.
• Strategic location of lamp socket, in combination with interior
prism design of the glass globe, provides optimum light
distribution and control.
• Choice of mountings – pendant, ceiling, bracket and stanchion.
• Optional guards protect globes from damage. Secured to fixture
with three stainless steel screws.
• Fiberglass reinforced polyester reflectors, in standard dome
or 30° angle styles, are ideal in installations where luminaire is
subject to exceptionally severe corrosive atmospheres. The
high bay aluminum reflector is intended for installations where
mounting height work planes range from 20 to 30 feet/6 to 9
meters.
• Fluorescent lamp life of 10,000 hours reduces relamping cost
compared to incandescent, and pr •
Ballast bodies
and guards: copperfree (4/10 of 1% max.) aluminum
• Pendant mounting hoods: diecast copperfree (4/10 of 1% max.)
aluminum
• Ceiling, bracket and stanchion mounting hoods: sand cast
copperfree (4/10 of 1% max.) aluminum
• Reflectors: fiberglass reinforced polyester (white) or
aluminum
26-42W Code•Master Jr. PLT
52-84W Code•Master 2 PLT
Illustrated Features
Mounting Hood
Collector Ring
and Pin
Connection Block
Double Lead
Acme Threads
As Fixture unit is threaded into mounting
hood an automatic electrical connection is made.
Standard Finishes
• Ballast bodies, guards and mounting hoods: epoxy powder
coat finish, electrostatically applied for complete, uniform
corrosion protection
Certifications and Compliances
• UL Standard: UL 1598, UL 844
• UL Listed: E10444
Fixtures are for use with Group B atmospheres only when used with Group B mounting hoods. For 26 W,32 W, and 42 W fixtures only.
V CSA Certification only.
1240
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
Code•Master™ PLT Factory Sealed Luminaires
Explosionproof, Dust-Ignitionproof
Integrally Ballasted. 26 W, 32 W, 42 W, 52 W, 64 W, 84 W Compact Fluorescent. For use with Threaded Metal Conduit.
NEC:
Class I, Division 1 and 2, Groups B, C, D
Class II, Division 1 and 2, Groups E, F, G
Class III
NEMA 4X
Suitable for use in wet locations
Exd IIB + H2
Suitable for use in wet locations
CEC: V
Class I, Division 1 and 2, Groups B, C, D
Class I, Zone 1 and 2, Groups IIB + H2 T6
Class II, Division 1 and 2, Groups E, F, G
Class III
CSA 4X
Catalog Numbering Guide
CJ
F
P
26
75
Mouning:
P - Pendant
C - Ceiling
B - Bracket
S - Stanchion
PB - Group B Pendant ◆
SB - Group B Stanchion ◆
Series:
CJ - Code•Master
Jr. ◆
C - Code•Master 2
Hub Size:
75 - 3/4”
10 - 1”
150 - 1-1/2” or 1-1/4”
Wattage:
26 - 26 Watts
32 - 32 Watts
42 - 42 Watts
52 - 52 Watts
64 - 64 Watts
84 - 84 Watts
BU
L
Voltage:
BU - 120-277 V 50/60 Hz
A5 - 347 V 60 Hz V
Guard:
G - Guard provided
Blank - Guard not provided
Options:
L - Lamps Provided
F - Fused
Z - Zone 1
Exd IIB + H2 V
Classified Area Suitability of Code•Master™ Series PLT Fixtures — Suitability includes use of reflector
Lamp
Type
PLT
(4-pin)
PLT
(4-pin)
PLT
(4-pin)
Class I, Division 1 & 2 with Globe or
with Globe & Reflector
UL/NEC Temp. Ident. No.
Class II, Division 1 & 2 with Globe or
with Globe & Reflector
UL/NEC Temp. Ident. No.
Supply
Wire
°F/°C
Ambient
Temp
°F/°C
Nameplate
Marking
Groups
Nameplate
Marking
Groups
26
167/75
104/40
T6
B◆,C,D
T4A
E, F, G
32
167/75
104/40
T6
B◆,C,D
T4A
E, F, G
42
167/75
104/40
T6
B◆,C,D
T4A
E, F, G
167/75
167/75
167/75
167/75
167/75
167/75
167/75
167/75
167/75
104/40
131/55
149/65
104/40
131/55
149/65
104/40
131/55
149/65
T6
T5
T5
T6
T5
T5
T6
T5
T5
C, D
C, D
C, D
C, D
C, D
C, D
C, D
C, D
C, D
T4
—
—
T4
—
—
T4
—
—
E, F, G
—
—
E, F, G
—
—
E, F, G
—
—
PLT
(4-pin)
52
(2 x 26)
PLT
(4-pin)
64
(2 x 32)
PLT
(4-pin)
84
(2 x 42)
Lighting
Lamp
Watts
“T” Numbers Represent the Maximum Surface Temperature for Class I, Division 1 Locations and
Maximum Surface Temperature Under Dust Blanket for Class II, Division 1 Locations.
“T”
Number
T1
350
325
T2
T2A
T2B
T2C
T2D
T3
T3A
T3B
T3C
T4
T4A
T5
T6
Temp
Range
(°F)
664842
619662
574617
538572
502536
448500
421446
394419
358392
331356
322329
277320
250275
214248
187212
185
Temp.
Range
(°˚C)
351450
326350
301325
281300
261280
231260
216230
201215
181200
166180
161165
136160
121135
101120
86-100
85
Fixtures are for use with Group B atmospheres only when used with Group B mounting hoods. For 26 W,32 W, and 42 W fixtures only.
V CSA Certification only.
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
Lighting: Explosionproof — Area — Fluorescent
Lamp Type:
F - Fluorescent
G
1241
Code•Master™ PLT Factory Sealed Luminaires
Explosionproof, Dust-Ignitionproof
Integrally Ballasted. 26 W, 32 W, 42 W, 52 W, 64 W, 84 W Compact Fluorescent. For use with Threaded Metal Conduit.
NEC:
Class I, Division 1 and 2, Groups B, C, D
Class II, Division 1 and 2, Groups E, F, G
Class III
NEMA 4X
Suitable for use in wet locations
Lamp
Watts
Hub Size
(Inches)
Catalog Number
with Globe ➊
26
3/4
CJFPB2675BU
32
3/4
CJFPB3275BU
42
3/4
CJFPB4275BU
26
1-1/2
CJFSB26150BU
32
1-1/2
CJFSB32150BU
42
1-1/2
CJFSB42150BU
25° Stanchion
One Hub
Mounting Hoods
Hub Size
Inches
Catalog
Number
3/4
CAP-75B
1-1/2
CAS-150B
Pendant — One Hub
Lighting
Lighting: Explosionproof — Area — Fluorescent
Pendant — One Hub, Rigid or Flexible Mounting
25° Stanchion — One Hub ➋
NOTE: Fixture units are the same as listed on following pages.
Fixtures are for use with Group B atmospheres only when used with Group B mounting hoods. For 26 W,32 W, and 42 W fixtures only.
➊ To order fixture with guard, add suffix -G before adding voltage suffix.
➊ To order fixture with lamp(s), add suffix -L after voltage suffix.
➋ Malleable iron sealing fittings are available in the Fittings Section.
1242
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
Code•Master™ PLT Factory Sealed Luminaires
Explosionproof, Dust-Ignitionproof
Integrally Ballasted. 26 W, 32 W, 42 W, 52 W, 64 W, 84 W Compact Fluorescent. For use with Threaded Metal Conduit.
NEC:
Class I, Division 1 and 2, Groups C, D
Class II, Division 1 and 2, Groups E, F, G
Class III
NEMA 4X
Suitable for use in wet locations
CEC: V
Class I, Division 1 and 2, Groups B, C, D
Class I, Zone 1 and 2, Groups IIB + H2 T6
Class II, Division 1 and 2, Groups E, F, G
Class III
CSA 4X
Lamp
Watts
Pendant — One Hub, Rigid or Flexible Mounting
26 (1 x 26)
32 (1 x 32)
42 (1 x 42)
52 (2 x 26)
64 (2 x 32)
26 (1 x 26)
32 (1 x 32)
42 (1 x 42)
52 (2 x 26)
64 (2 x 32)
84 (2 x 42)
52-84 W Shown
Bracket — Four Hubs, Three Close-Up Plugs
26 (1 x 26)
32 (1 x 32)
42 (1 x 42)
64 (2 x 32)
26-42 W Shown
84 (2 x 42)
25° Stanchion — One Hub
26 (1 x 26)
32 (1 x 32)
42 (1 x 42)
52 (2 x 26)
64 (2 x 32)
84 (2 x 42)
NEC/CEC V
Catalog Number
with Globe ➊➌
CEC V
Catalog Number
with Globe ➊➌
3/4
1
3/4
1
3/4
1
3/4
1
3/4
1
3/4
1
CJFP2675BU
CJFP2610BU
CJFP3275BU
CJFP3210BU
CJFP4275BU
CJFP4210BU
CFP5275BU
CFP5210BU
CFP6475BU
CFP6410BU
CFP8475BU
CFP8410BU
CJFP2675A5
CJFP2610A5
CJFP3275A5
CJFP3210A5
CJFP4275A5
CJFP4210A5
CFP5275A5
CFP5210A5
CFP6475A5
CFP6410A5
CFP8475A5
CFP8410A5
3/4
1
3/4
1
3/4
1
3/4
1
3/4
1
3/4
1
CJFC2675BU
CJFC2610BU
CJFC3275BU
CJFC3210BU
CJFC4275BU
CJFC4210BU
CFC5275BU
CFC5210BU
CFC6475BU
CFC6410BU
CFC8475BU
CFC8410BU
CJFC2675A5
CJFC2610A5
CJFC3275A5
CJFC3210A5
CJFC4275A5
CJFC4210A5
CFC5275A5
CFC5210A5
CFC6475A5
CFC6410A5
CFC8475A5
CFC8410A5
3/4
1
3/4
1
3/4
1
3/4
1
3/4
1
3/4
1
CJFB2675BU
CJFB2610BU
CJFB3275BU
CJFB3210BU
CJFB4275BU
CJFB4210BU
CFB5275BU
CFB5210BU
CFB6475BU
CFB6410BU
CFB8475BU
CFB8410BU
CJFB2675A5
CJFB2610A5
CJFB3275A5
CJFB3210A5
CJFB4275A5
CJFB4210A5
CFB5275A5
CFB5210A5
CFB6475A5
CFB6410A5
CFB8475A5
CFB8410A5
1-1/4 or 1-1/2 ➋
1-1/4 or 1-1/2 ➋
1-1/4 or 1-1/2 ➋
1-1/4 or 1-1/2 ➋
1-1/4 or 1-1/2 ➋
1-1/4 or 1-1/2 ➋
CJFS26150BU
CJFS32150BU
CJFS42150BU
CFS52150BU
CFS64150BU
CFS84150BU
CJFS26150A5
CJFS32150A5
CJFS42150A5
CFS52150A5
CFS64150A5
CFS84150A5
Lighting
52 (2 x 26)
Hub Size
(Inches)
Lighting: Explosionproof — Area — Fluorescent
84 (2 x 42)
26-42 W Shown
Ceiling — Four Hubs, Three Close-Up Plugs
Exd IIB + H2
Suitable for use in wet locations
52-84 W Shown
➊ To order fixture with guard, add suffix -G before adding voltage suffix. To order fixture with lamp(s), add suffix -L after voltage suffix.
➋ 1-1/2” tapped hub furnished with 1-1/2” to 1-1/4” reducer.
➌ BU is 120 through 277 V, 50/60 Hz and 125 Vdc. A5 is 347 V, 60 Hz V.
V CSA Certification only.
Shaded items are suitable for Class I, Group D ONLY.
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
1243
Code•Master™ PLT Factory Sealed Luminaire Mounting Hoods and Fixture Units
Explosionproof, Dust-Ignitionproof
Integrally Ballasted. 26 W, 32 W, 42 W, 52 W, 64 W, 84 W Compact Fluorescent. For use with Threaded Metal Conduit.
NEC:
Class I, Division 1 and 2, Groups C, D
Class II, Division 1 and 2, Groups E, F, G
Class III
NEMA 4X
Suitable for use in wet locations
CEC: V
Class I, Division 1 and 2, Groups B, C, D
Class I, Zone 1 and 2, Groups IIB + H2 T6
Class II, Division 1 and 2, Groups E, F, G
Class III
CSA 4X
Exd IIB + H2
Suitable for use in wet locations
Mounting Hoods
Hub Size
(Inches)
Catalog
Number
Pendant
3/4
CAP-75
1
CAP-100
3/4
CAC-75
1
CAC-100
3/4
CALB-75
1
CALB-100
1-1/4 or 1-1/2 ➊
CAS-150 ➊
Lighting: Explosionproof — Area — Fluorescent
Ceiling
Bracket
25° Stanchion
Mounting Adapter with Connection Block
CMAD-1
Fixture Units
Line
Voltage
Hz
Catalog
Number
120-277
50/60
CJB26FBU ➋
120-277
50/60
CJB32FBU ➋
120-277
50/60
CJB42FBU ➋
120-277
50/60
CMBF52BU
120-277
50/60
CMBF64BU
120-277
50/60
CMBF84BU
Lighting
Ballast body with globe
26-42 W
52-84 W
Electrical Specification
Lamp Wattage
Line Voltage
Frequency (Hz)
Line Amps
Input Watts
Min. Starting Temp
26 (1 x 26)
120-277
50/60
0.25-0.11
28
0 °F/-18 °C
32 (1 x 32)
120-277
50/60
0.27-0.12
36
0 °F/-18 °C
42 (1 x 42)
120-277
50/60
0.35-0.16
48
0 °F/-18 °C
52 (2 x 26)
120-277
50/60
0.49-0.20
55
-22 °F/-30 °C
64 (2 x 32)
120-277
50/60
0.57-0.24
67
-22 °F/-30 °C
84 (2 x 42)
120-277
50/60
0.73-0.31
87
-22 °F/-30 °C
➊ 1-1/2” tapped hub furnished with 1-1/2” to 1-1/4” reducer.
➋ Denotes items that are suitable for Class I, Group B in addition to Class I, Groups C and D; and Class II, Groups E, F and G.
V CSA Certification only.
Shaded items are suitable for Class I, Group C in addition to Class I, Group D; Class II, Groups E, F and G; and Class III.
1244
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
Code•Master™ PLT Factory Sealed Luminaire Accessories
Explosionproof, Dust-Ignitionproof
Integrally Ballasted. 26 W, 32 W, 42 W, 52 W, 64 W, 84 W Compact Fluorescent. For use with Threaded Metal Conduit.
Catalog
Number
Description
White Polyester Reflectors
Furnished with stainless steel screws
For Globe Fixtures
Standard Dome
30° Angle Dome
Standard Dome
26, 32, 42 W
KR2-ST
30°Angle
26, 32, 42 W
KR2-AN
Standard Dome
52, 64, 84 W
CMR-4ST
30°Angle
52, 64, 84 W
CMR-4AN
Deep Dome
52, 64, 84 W
CMR-4DD
High Bay
52, 64, 84 W
CMR-4HB
Aluminum Reflectors
Lighting: Explosionproof — Area — Fluorescent
Prismatic Glass Globe and Ring Assembly
CJGL-175
26, 32, 42 W
CJGL-175
52, 64, 84 W
CGL-400
26, 32, 42 W
CJGU-15
52, 64, 84 W
CGU-4
CGL-400
Aluminum Guards
CJGU-15
CGU-4
Lighting
Three-Way Exit Sign
Epoxy enameled steel — 6”-high red lettering
Mounts to fixture units in place of guard.
26, 32, 42 W
CJEXRN
52, 64, 84 W
EXR400
Single Sided Exit Sign
Epoxy enameled steel — 6”-high red lettering
Mounts to fixture units in place of guard.
Contact your sales representative regarding hazardous location suitability.
26, 32, 42 W
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
AEXR-15R
1245
Code•Master™ PLT Factory Sealed Luminaire Accessories
Explosionproof, Dust-Ignitionproof
Integrally Ballasted. 26 W, 32 W, 42 W, 52 W, 64 W, 84 W Compact Fluorescent. For use with Threaded Metal Conduit.
Description
Catalog Number
Replacement Parts – 26 W, 32 W, 42 W, 52 W, 64 W and 84 W
Lighting: Explosionproof — Area — Fluorescent
PLT32RS
CJSA42
Socket (lampholder) G24Q-4
26 thru 84 W
PLT32RS
Single Socket Bracket Assembly
26, 32, 42 W
CJSA42
Double Socket Bracket Assembly
52, 64, 84 W
CSA84
1 lamp = 26 W; 2 lamps = 52 W
26 W
PLT26
1 lamp = 32 W; 2 lamps = 64 W
32 W
PLT32
1 lamp = 42 W; 2 lamps = 84 W
42 W
PLT42
26, 32, 42 W
59661256001
52, 64, 84 W
59661259001
CSA84
Lamps
Replacement Ballast
Connection Block
VPT-7
Lighting
For all Code•Master fixtures
Fixture and Accessory Weights lbs/kgs
Mounting Hood Weights lbs/kgs
Fixture Size
Fixture Weight
Reflector Weight
Guard Weight
Pendant
Ceiling
Bracket
Stanchion
26 W, 32 W, 42 W
14.5/6.6
3.0/1.4
1.0/0.5
2/0.9
4/1.8
6/2.7
2/0.9
52 W, 64 W, 84 W
35.0/15.9
3.0/1.4
2.5/1.1
Reflector Dimensions
Catalog
Number
Description
Standard Dome
KR2-ST
26, 32, 42 W
CMR-4ST
52, 64, 84 W
Deep Dome
CMR-4DD
52, 64, 84 W
30° Angle
KR2-AN
26, 32, 42 W
CMR-4AN
52, 64, 84 W
1246
A
Dimensions in In/mm
B
C
D
Standard and Deep Dome
30° Angle
A
8.00/203.2
11.20/284.5
6.00/152.4
5.90/149.9
16.90/429.3
18.70/475.0
—
—
10.56/268.2
7.00/177.8
20.30/515.6
—
A
B
B
D
C
8.00/203.2
10.56/268.2
2.75/69.9
5.00/127
14.90/378.5
16.16/410.5
10.17/258.3
9.75/247.7
C
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
Code•Master™ PLT Factory Sealed Luminaire Dimensions
Explosionproof, Dust-Ignitionproof
Integrally Ballasted. 26 W, 32 W, 42 W, 52 W, 64 W, 84 W Compact Fluorescent. For use with Threaded Metal Conduit.
Mounting Hoods
Pendant
Ceiling
Bracket
4.00"/
101.6 mm
9.86"/
250.4 mm
4.00"/
101.6 mm
17.61"/
447.3 mm
4.25"/
108.0 mm
4.92"/125.0 mm Sq.
4.50"/
114.3 mm
20.50"/
520.7 mm
9.50"/
241.3 mm
6.10"/
155.0 mm
2.46"/
2.28"/
62.9 mm 57.9 mm
3.91"/99.3 mm
21.50"/
546.1 mm
25° Stanchion
1.23"/
31.2 mm
3.48"/
88.4 mm
3.92"/
99.6 mm
5.92"/
150.4 mm
1.79"/
45.7 mm
2.38"/
60.5 mm
Dia.
4.50"/
114.3 mm
Dia.
11.5"/
292.1 mm
13.75"/
349.3 mm
12.00"/
304.8 mm
26, 32, 42 W Fixture
17.87"/
453.9 mm
16.00"/
406.4 mm
16.88"/
428.8 mm
17.47"/
443.7 mm
7.40"/
188.0 mm
18.12"/
460.2 mm
7.40"/
188.0 mm
14.12"/
358.6 mm
14.12"/
358.6 mm
16.25"/
412.8 mm
16.00"/
406.4 mm
8.00"/
203.2 mm
8.00"/
203.2 mm
15.62"/
396.7 mm
16.25"/
412.8 mm
4.00"/
101.6 mm
3.75"/95.3 mm
7.40"/
188.0 mm
17.22"/
437.9 mm
23.61"/
599.7 mm
24.61"/
625.1 mm
20.36"/
517.1 mm
9.86"/
250.4 mm
20.36"/
517.1 mm
17.5"/
444.5 mm
12.0"/
304.8 mm
12.0"/
304.8 mm
Lighting
20.36"/
517.1 mm
9.86"/
250.4 mm
24.36"/
618.7 mm
9.86"/
250.4 mm
23.36"/
593.3 mm
23.5"/
596.9 mm
24.5"/
622.3 mm
3.91"/
99.3 mm
21.2"/
538.5 mm
22.2"/
563.9 mm
52, 64, 84 W Fixture
5.5"/
139.7 mm
17.5"/
444.5 mm
Exit Signs
9.25"/
235.0 mm
6.88"/
174.8 mm
11.75"/298.5 mm
12.00"/
304.8 mm
CJEXRN
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
Lighting: Explosionproof — Area — Fluorescent
0.94"/
23.9 mm
4.58"/
116.3 mm
Dia.
8.50"/
215.9 mm
AEXR-15R
1247
Code•Master™ PLT Factory Sealed Luminaire Photometric Data
Explosionproof, Dust-Ignitionproof
Integrally Ballasted. 26 W, 32 W, 42 W, 52 W, 64 W, 84 W Compact Fluorescent. For use with Threaded Metal Conduit.
* Photometric data is based on a fixture with
a 32 W compact fluorescent PL-T lamp (2,400
lumens). For candlepower values of fixtures
with 26 W PL-T lamps (1,800 lumens), multiply by
0.75. For candlepower values of fixtures with a
42 W PL-T Lamp (3,200 lumens), multiply by 1.34.
Total Luminaire Efficiency = 92.9%
CIE Type - Semi-Direct
Plane
Spacing
Criteria
0-180
2.76
90-270
2.76
Diagonal
2.72
REPORT NUMBER: CJBF32G
32 W Fluorescent Lamp with Globe only *
Coefficients of Utilization - Zonal Cavity Method
Effective Floor Cavity Reflectance 0.20
% Ceiling Rcc
Lighting: Explosionproof — Area — Fluorescent
% Walls
Zone
0-10
10-20
20-30
30-40
40-50
50-60
60-70
70-80
80-90
90-100
100-110
Lumens
9.75
32.89
68.63
119.65
174.44
219.68
252.32
278.38
283.11
266.38
231.16
110-120
166.66
120-130
130-140
140-150
150-160
160-170
170-180
91.63
31.38
2.95
0.19
0.00
0.00
0
1
2
3
4
5
6
7
8
9
10
Maximum Candela = 265
Located at Horizontal Angle = 0, Vertical Angle = 77.5
#1 - Vertical Plane through Horizontal Angles (0-180)
(Through Max. Cd.)
#2 - Horizontal Cone through Vertical Angle (77.5)
(Through Max. Cd.)
CIE Type - Direct
Lighting
Plane
Spacing
Criteria
1.42
90-270
1.42
Diagonal
1.60
Zone
0-30
0-40
0-60
0-90
110-120
6.82
5.50
3.07
0.09
0.00
0.00
0.00
1248
30
10
0
30
10
70
50
30
10
50
30
10
50
30
10
50
30
10
0
103
88
78
69
63
57
52
48
44
41
38
103
81
67
57
50
43
38
34
31
28
25
103
75
59
48
40
34
29
25
22
20
18
103
70
52
41
33
27
23
19
17
14
13
97
82
72
64
58
52
48
44
41
38
35
97
76
63
53
46
40
36
32
29
26
24
97
70
55
45
37
32
27
24
21
19
17
97
65
49
38
31
25
21
18
16
14
12
85
65
54
46
39
35
31
27
25
23
21
85
61
48
39
32
27
24
21
18
16
15
85
57
43
33
27
22
18
16
14
12
10
74
56
46
39
33
29
26
23
21
19
18
74
53
41
33
28
23
20
18
16
14
12
74
50
37
29
23
19
16
13
11
10
9
65
48
38
32
28
24
21
19
18
16
15
65
45
35
28
23
19
17
15
13
12
10
65
42
31
24
19
16
13
11
9
8
7
60
38
27
20
16
13
10
9
7
6
5
Lumens
111.27
230.92
625.05
1438.87
% Lamp
4.6
9.6
26.0
60.0
% Fixture
5.0
10.4
28.0
64.5
Zone
90-120
90-130
90-150
90-180
0-180
Lumens
664.20
755.83
790.17
790.36
2229.23
% Lamp
27.7
31.5
32.9
32.9
92.9
% Fixture
29.8
33.9
33.9
35.5
100.0
Coefficients of Utilization - Zonal Cavity Method
Effective Floor Cavity Reflectance 0.20
% Ceiling Rcc
Lumens
51.88
151.03
240.04
312.02
361.09
377.88
278.20
119.22
23.81
0.68
4.48
120-130
130-140
140-150
150-160
160-170
170-180
50
50
REPORT NUMBER: CJBF32ST
32 W Fluorescent Lamp with Globe and Standard Dome Reflector *
% Walls
Zone
0-10
10-20
20-30
30-40
40-50
50-60
60-70
70-80
80-90
90-100
100-110
70
70
Zonal Lumen Summary
Total Luminaire Efficiency = 80.7%
0-180
Rw
80
Rw
0
1
2
3
4
5
6
7
8
9
10
80
70
50
30
10
0
70
50
30
10
70
50
30
10
50
30
10
50
30
10
50
30
10
0
96
87
79
72
65
60
55
51
47
44
41
96
84
72
63
55
49
44
39
36
33
30
96
80
67
56
48
41
36
32
29
26
23
96
77
62
51
42
36
31
27
24
21
19
93
85
77
70
63
58
53
49
46
43
40
93
82
71
62
54
48
43
39
35
32
30
93
78
66
55
47
41
36
32
28
26
23
93
76
61
50
42
36
31
27
24
21
19
89
78
68
59
52
46
41
37
34
31
29
89
75
63
54
46
40
35
31
28
25
23
89
73
60
49
41
35
30
27
23
21
19
85
75
65
57
50
44
40
36
33
30
28
85
73
61
52
45
39
34
30
27
25
23
85
71
58
48
41
35
30
26
23
21
19
82
72
62
54
48
43
39
35
32
29
27
82
70
59
51
44
38
34
30
27
24
22
82
68
57
47
40
34
30
26
23
21
19
80
67
55
45
38
32
28
24
21
19
17
Zonal Lumen Summary
Maximum Candela = 545
Located at Horizontal Angle = 0, Vertical Angle = 5
#1 - Vertical Plane through Horizontal Angles (0-180)
(Through Max. Cd.)
#2 - Horizontal Cone through Vertical Angle (5)
(Through Max. Cd.)
Zone
0-30
0-40
0-60
0-90
Lumens
442.95
754.97
1493.95
1915.18
% Lamp
18.5
31.5
62.2
79.8
% Fixture
22.9
39.0
77.2
98.9
Zone
90-120
90-130
90-150
90-180
0-180
Lumens
11.98
17.48
20.63
20.63
1935.81
% Lamp
0.5
0.7
0.9
0.9
80.7
% Fixture
0.6
0.9
0.9
1.1
100.0
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
Code•Master™ PLT Factory Sealed Luminaire Photometric Data
Explosionproof, Dust-Ignitionproof
Integrally Ballasted. 26 W, 32 W, 42 W, 52 W, 64 W, 84 W Compact Fluorescent. For use with Threaded Metal Conduit.
* Photometric data is based on a fixture with
a 32 W compact fluorescent PL-T lamp (2,400
lumens). For candlepower values of fixtures
with 26 W PL-T lamps (1,800 lumens), multiply by
0.75. For candlepower values of fixtures with a
42 W PL-T Lamp (3,200 lumens), multiply by 1.34.
** Photometric data is based on a fixture
with two 32 W Compact Fluorescent PL-T
lamps (2,400 lumens each). For candlepower
values of fixtures with two 26 W PL-T lamps
(1,800 lumens each), multiply by 0.75. For
Candlepower values of fixtures with two 42 W
Total Luminaire Efficiency = 76.6%
CIE Type - Direct
Plane
Spacing
Criteria
0-180
1.48
90-270
1.62
Diagonal
1.54
REPORT NUMBER: CJBF32AN
32 W Fluorescent Lamp with Globe and 30° Angle Dome Reflector *
Coefficients of Utilization - Zonal Cavity Method
Effective Floor Cavity Reflectance 0.20
% Ceiling Rcc
% Walls
Lumens
42.08
124.46
205.20
273.31
299.53
283.93
240.60
181.91
110.47
50.28
18.05
110-120
5.01
120-130
130-140
140-150
150-160
160-170
170-180
1.80
1.13
0.05
0.00
0.00
0.00
0
1
2
3
4
5
6
7
8
9
10
Maximum Candela = 467
Located at Horizontal Angle = 90, Vertical Angle = 40
#1 - Vertical Plane through Horizontal Angles (90-270)
(Through Max. Cd.)
#2 - Horizontal Cone through Vertical Angle (40)
(Through Max. Cd.)
CIE Type - Semi-Direct
Plane
Spacing
Criteria
2.88
Diagonal
2.82
Zone
0-30
0-40
0-60
0-90
Lumens
17.70
61.05
132.44
236.78
336.66
421.68
485.34
517.29
513.72
468.70
352.77
110-120
200.85
120-130
73.54
130-140
140-150
150-160
160-170
170-180
11.28
1.12
0.31
0.06
0.00
30
10
0
30
10
70
50
30
10
50
30
10
50
30
10
50
30
10
0
90
81
73
66
60
55
50
47
43
40
38
90
76
65
57
50
44
39
36
32
30
27
90
72
59
50
42
37
32
28
25
23
21
90
69
54
44
37
31
27
23
21
18
17
88
78
70
63
58
53
49
45
42
39
36
88
74
64
55
48
43
39
35
32
29
27
88
71
58
49
42
36
32
28
25
23
21
88
67
53
44
36
31
27
23
21
18
17
83
70
60
52
46
41
37
33
30
28
26
83
67
56
47
40
35
31
27
24
22
20
83
64
52
42
35
30
26
23
20
18
16
79
67
57
50
44
39
35
32
29
27
25
79
64
53
45
39
34
30
26
24
22
20
79
62
50
41
35
30
26
22
20
18
16
75
63
54
47
42
37
34
31
28
26
24
75
61
51
43
37
33
29
26
23
21
19
75
59
48
40
34
29
25
22
20
18
16
73
58
46
38
32
27
23
20
18
16
14
Lumens
371.75
645.06
1228.52
1761.50
% Lamp
15.5
26.9
51.2
73.4
% Fixture
20.2
35.1
66.8
95.8
Zone
90-120
90-130
90-150
90-180
0-180
Lumens
73.34
75.13
76.32
76.32
1837.81
% Lamp
3.1
3.1
3.2
3.2
76.6
% Fixture
4.0
4.1
4.1
4.2
100.0
REPORT NUMBER: CMBF64G
64 W (two 32 W lamps) Fluorescent Fixture with Globe only **
Coefficients of Utilization - Zonal Cavity Method
Effective Floor Cavity Reflectance 0.20
% Ceiling Rcc
% Walls
Zone
0-10
10-20
20-30
30-40
40-50
50-60
60-70
70-80
80-90
90-100
100-110
50
50
80
70
50
30
10
0
Rw
70
50
30
10
70
50
30
10
50
30
10
50
30
10
50
30
10
0
0
1
2
3
4
5
6
7
8
9
10
90
76
67
60
54
49
45
41
38
35
33
90
70
58
49
43
37
33
29
26
24
22
90
65
51
41
34
29
25
22
19
17
15
90
60
45
35
28
23
19
16
14
12
11
85
71
63
56
50
46
42
38
36
33
31
85
66
55
46
40
35
31
28
25
23
21
85
61
48
39
32
27
23
20
18
16
14
85
57
42
33
26
22
18
15
13
11
10
76
58
48
40
35
31
27
24
22
20
18
76
54
43
34
28
24
21
18
16
14
13
76
51
38
29
23
19
16
14
12
10
9
68
51
42
35
30
26
23
21
19
17
16
68
48
37
30
25
21
18
16
14
12
11
68
45
34
26
21
17
14
12
10
9
8
60
45
36
30
26
23
20
18
16
15
14
60
42
32
26
21
18
16
14
12
11
10
60
40
29
23
18
15
12
10
9
8
7
57
36
26
20
15
12
10
8
7
9
5
Zonal Lumen Summary
Maximum Candela = 493
Located at Horizontal Angle = 0, Vertical Angle = 70
#1 – Vertical Plane through Horizontal Angles (0-180)
(Through Max. Cd.)
#2 – Horizontal Cone through Vertical Angle (70)
(Through Max. Cd.)
Zone
0-30
0-40
0-60
0-90
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
Lumens
211.19
447.97
1206.31
2722.64
% Lamp
4.4
9.3
25.1
56.7
% Fixture
5.5
11.7
31.5
71.1
Zone
90-120
90-130
90-150
90-180
0-180
Lumens
1022.32
1095.85
1108.26
1108.63
3831.28
% Lamp
21.3
22.8
23.1
23.1
79.8
% Fixture
26.7
28.6
28.6
28.9
100.0
1249
Lighting
2.88
90-270
70
70
Zonal Lumen Summary
Total Luminaire Efficiency = 79.8%
0-180
Rw
80
Lighting: Explosionproof — Area — Fluorescent
Zone
0-10
10-20
20-30
30-40
40-50
50-60
60-70
70-80
80-90
90-100
100-110
PL-T Lamps. (3,200 lumens each) multiply by
1.34.
Code•Master™ PLT Factory Sealed Luminaire Photometric Data
Explosionproof, Dust-Ignitionproof
Integrally Ballasted. 26 W, 32 W, 42 W, 52 W, 64 W, 84 W Compact Fluorescent. For use with Threaded Metal Conduit.
** Photometric data is based on a fixture
with two 32 W Compact Fluorescent PL-T
lamps (2,400 lumens each). For candlepower
values of fixtures with two 26 W PL-T lamps
(1,800 lumens each), multiply by 0.75. For
Candlepower values of fixtures with two 42 W
PL-T lamps. (3,200 lumens each) multiply by
1.34.
Total Luminaire Efficiency = 66.5%
CIE Type - Direct
Plane
Spacing
Criteria
0-180
1.62
90-270
1.62
Diagonal
1.74
REPORT NUMBER: CMBF64ST
64 W (two 32 W lamps) Fluorescent Fixture with Globe and
Standard Dome Reflector **
Coefficients of Utilization - Zonal Cavity Method
Effective Floor Cavity Reflectance 0.20
% Ceiling Rcc
Lighting: Explosionproof — Area — Fluorescent
% Walls
Zone
0-10
10-20
20-30
30-40
40-50
50-60
60-70
70-80
80-90
90-100
100-110
Lumens
73.25
220.57
368.60
505.61
603.19
638.42
497.24
226.17
57.98
1.64
0.00
110-120
0.00
120-130
130-140
140-150
150-160
160-170
170-180
0.00
0.00
0.00
0.00
0.00
0.00
Maximum Candela = 808
Located at Horizontal Angle = 0, Vertical Angle = 35
#1 – Vertical Plane through Horizontal Angles (0-180)
(Through Max. Cd.)
#2 – Horizontal Cone through Vertical Angle (35)
(Through Max. Cd.)
CIE Type - Direct
Lighting
Spacing
Criteria
0-180
1.52
90-270
1.70
Diagonal
1.62
Zone
0-30
0-40
0-60
0-90
110-120
0.00
0.00
0.00
0.00
0.00
0.00
0.00
1250
30
10
0
50
30
10
70
50
30
10
50
30
10
50
30
10
50
30
10
0
0
1
2
3
4
5
6
7
8
9
10
79
72
65
59
53
49
45
41
38
35
33
79
69
59
51
45
39
35
32
29
26
24
79
66
54
45
38
33
29
25
23
20
18
79
63
50
41
34
28
24
21
19
16
15
77
70
63
57
52
47
43
40
37
34
32
77
67
58
50
44
39
34
31
28
26
24
77
64
53
45
38
33
29
25
22
20
18
77
62
49
40
33
28
24
21
18
16
15
74
64
55
48
42
37
33
30
27
25
23
74
62
52
43
37
32
28
25
22
20
18
74
60
48
40
33
28
24
21
18
16
15
71
62
53
46
40
36
32
29
26
24
22
71
60
50
42
36
31
27
24
22
19
18
71
58
47
39
32
28
24
21
18
16
15
68
59
51
44
39
35
31
28
26
23
22
68
58
48
41
35
31
27
24
21
19
17
68
56
46
38
32
27
23
20
18
16
14
66
55
45
37
30
26
22
19
17
15
13
Lumens
662.42
1168.03
2409.64
3191.04
% Lamp
13.8
24.3
50.2
66.5
% Fixture
20.7
36.6
75.5
99.9
Zone
Lumens
90-120
1.64
90-130
1.64
90-150
1.64
90-180
1.64
0-180 3192.68
% Lamp
0.0
0.0
0.0
0.0
66.5
% Fixture
0.1
0.1
0.1
0.1
100.0
Coefficients of Utilization - Zonal Cavity Method
Effective Floor Cavity Reflectance 0.20
% Ceiling Rcc
Lumens
62.13
187.93
317.49
428.14
471.22
454.23
384.77
276.31
157.68
13.45
0.00
120-130
130-140
140-150
150-160
160-170
170-180
50
70
REPORT NUMBER: CMBF64AN
64 W (two 32 W lamps) Fluorescent Fixture with Globe and
30° Angle Dome Reflector **
% Walls
Zone
0-10
10-20
20-30
30-40
40-50
50-60
60-70
70-80
80-90
90-100
100-110
70
Rw
Zonal Lumen Summary
Total Luminaire Efficiency = 57.4%
Plane
80
80
70
50
30
10
0
Rw
70
50
30
10
70
50
30
10
50
30
10
50
30
10
50
30
10
0
0
1
2
3
4
5
6
7
8
9
10
68
61
55
50
45
41
38
35
32
30
28
68
58
49
43
37
33
30
27
24
22
20
68
55
45
37
32
28
24
21
19
17
16
68
52
41
33
28
23
20
18
16
14
12
67
59
53
48
44
40
37
34
32
29
28
67
56
48
42
37
32
29
26
24
22
20
67
54
44
37
31
27
24
21
19
17
15
67
51
40
33
27
23
20
18
15
14
12
64
54
46
40
35
31
28
25
23
21
19
64
51
43
36
31
27
23
21
19
17
15
64
49
39
32
27
23
20
17
15
14
12
61
51
44
38
34
30
27
24
22
20
19
61
49
41
35
30
26
23
20
18
16
15
61
48
39
32
27
23
20
17
15
14
12
58
49
42
37
32
29
26
24
22
20
18
58
48
40
34
29
25
22
20
18
16
15
58
46
38
31
26
22
19
17
15
13
12
57
45
36
30
25
21
18
16
14
12
11
Zonal Lumen Summary
Maximum Candela = 731
Located at Horizontal Angle = 90, Vertical Angle = 37.5
#1 – Vertical Plane through Horizontal Angles (90-270)
(Through Max. Cd.)
#2 – Horizontal Cone through Vertical Angle (37.5)
(Through Max. Cd.)
Zone
0-30
0-40
0-60
0-90
Lumens
567.55
995.69
1921.14
2739.90
% Lamp
11.8
20.7
40.0
57.1
% Fixture
20.6
36.2
69.8
99.5
Zone
90-120
90-130
90-150
90-180
0-180
Lumens
13.45
13.45
13.45
13.45
2753.35
% Lamp
0.3
0.3
0.3
0.3
57.4
% Fixture
0.5
0.5
0.5
0.5
100.0
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
Code•Master™ PLT Factory Sealed Luminaire Photometric Data
Explosionproof, Dust-Ignitionproof
Integrally Ballasted. 26 W, 32 W, 42 W, 52 W, 64 W, 84 W Compact Fluorescent. For use with Threaded Metal Conduit.
** Photometric data is based on a fixture
with two 32 W Compact Fluorescent PL-T
lamps (2,400 lumens each). For candlepower
values of fixtures with two 26 W PL-T lamps
(1,800 lumens each), multiply by 0.75. For
Candlepower values of fixtures with two 42 W
PL-T Lamps. (3,200 lumens each) multiply by
1.34.
Total Luminaire Efficiency = 67.2%
CIE Type - Direct
Plane
Spacing
Criteria
0-180
1.44
90-270
1.44
Diagonal
1.60
REPORT NUMBER: CMBF64DD
64 W (two 32 W lamps) Fluorescent Fixture with Globe and
Deep Dome Reflector **
Coefficients of Utilization - Zonal Cavity Method
Effective Floor Cavity Reflectance 0.20
% Ceiling Rcc
% Walls
90-100
100-110
Lumens
88.95
260.61
413.34
539.82
630.36
641.74
436.60
164.84
47.37
1.92
0.00
110-120
0.00
120-130
130-140
140-150
150-160
160-170
170-180
0.00
0.00
0.00
0.00
0.00
0.00
Maximum Candela = 933
Located at Horizontal Angle = 0, Vertical Angle = 7.5
#1 – Vertical Plane through Horizontal Angles (0-180)
(Through Max. Cd.)
#2 – Horizontal Cone through Vertical Angle (7.5)
(Through Max. Cd.)
CIE Type - Direct
Plane
Spacing
Criteria
0.82
Diagonal
0.92
Zone
0-30
0-40
0-60
0-90
Lumens
239.15
599.67
645.20
625.54
452.95
185.71
58.40
15.26
4.25
0.69
0.00
110-120
0.00
120-130
130-140
140-150
150-160
160-170
170-180
0.00
0.00
0.00
0.00
0.00
0.00
10
0
30
10
70
50
30
10
50
30
10
50
30
10
50
30
10
0
0
1
2
3
4
5
6
7
8
9
10
80
73
66
60
55
50
46
43
40
37
34
80
70
61
53
47
41
37
33
30
28
25
80
67
56
47
41
35
31
27
24
22
20
80
65
52
43
36
31
26
23
20
18
16
78
71
65
59
53
49
45
41
38
36
34
78
68
59
52
46
41
36
33
30
27
25
78
66
55
47
40
35
30
27
24
22
20
78
63
52
43
36
30
26
23
20
18
16
75
66
57
50
44
39
35
32
29
26
24
75
63
53
45
39
34
30
27
24
21
19
75
61
50
42
35
30
26
23
20
18
16
71
63
55
48
42
38
34
31
28
26
24
71
61
52
44
38
33
29
26
23
21
19
71
60
49
41
35
30
26
23
20
18
16
69
60
53
46
41
37
33
30
27
25
23
69
59
50
43
37
33
29
26
23
21
19
69
58
48
40
34
29
25
22
20
18
16
67
56
47
39
33
28
24
21
19
16
15
Lumens
762.91
1302.73
2574.82
3223.63
% Lamp
15.9
27.1
53.6
67.2
% Fixture
23.7
40.4
79.8
99.9
Zone
90-120
90-130
90-150
90-180
0-180
Lumens
1.92
1.92
1.92
1.92
3225.55
% Lamp
0.0
0.0
0.0
0.0
57.4
% Fixture
0.1
0.1
0.1
0.1
100.0
REPORT NUMBER: CMBF64HB
64 W (two 32 W lamps) Fluorescent Fixture with Globe and High Bay Reflector **
Coefficients of Utilization - Zonal Cavity Method
Effective Floor Cavity Reflectance 0.20
% Ceiling Rcc
% Walls
Zone
0-10
10-20
20-30
30-40
40-50
50-60
60-70
70-80
80-90
90-100
100-110
30
50
80
70
50
30
10
0
Rw
70
50
30
10
70
50
30
10
50
30
10
50
30
10
50
30
10
0
0
1
2
3
4
5
6
7
8
9
10
70
66
62
58
55
51
48
46
43
41
38
70
64
59
54
50
46
42
39
37
34
32
70
63
56
51
46
42
38
35
33
30
28
70
61
54
48
43
39
35
32
30
28
26
68
65
61
57
54
50
47
45
42
40
38
68
63
58
53
49
45
42
39
36
34
32
68
62
55
50
45
41
38
35
32
30
28
68
60
53
47
43
39
35
32
30
28
26
65
61
56
51
48
44
41
38
36
33
31
65
59
54
49
44
41
37
35
32
30
28
65
58
52
47
42
38
35
32
30
27
26
63
58
54
50
46
43
40
37
35
33
31
63
57
52
48
44
40
37
34
32
30
28
63
57
51
46
42
38
35
32
29
27
25
60
56
52
49
45
42
39
37
34
32
30
60
56
51
47
43
39
36
34
31
29
27
60
55
50
45
41
37
34
32
29
27
25
59
54
49
44
40
36
33
31
28
26
25
Zonal Lumen Summary
Maximum Candela = 2540
Located at Horzonatl Angle = 0, Vertical Angle = 5
#1 – Vertical Plane through Horizontal Angles (0-180)
(Through Max. Cd.)
#2 – Horizontal Cone through Vertical Angle (5)
(Through Max. Cd.)
Zone
0-30
0-40
0-60
0-90
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
Lumens
1484.03
2109.57
2748.23
2826.12
% Lamp
30.9
43.9
57.3
58.9
% Fixture
52.5
74.6
97.2
100.0
Zone
Lumens
90-120
0.69
90-130
0.69
90-150
0.69
90-180
0.69
0-180 2628.80
% Lamp
0.0
0.0
0.0
0.0
58.9
% Fixture
0.0
0.0
0.0
0.0
100.0
1251
Lighting
0.82
90-270
50
70
Zonal Lumen Summary
Total Luminaire Efficiency = 58.9%
0-180
70
Rw
Lighting: Explosionproof — Area — Fluorescent
Zone
0-10
10-20
20-30
30-40
40-50
50-60
60-70
70-80
80-90
80
APL Two and Four Lamp Fluorescent Factory Sealed Luminaires
Explosionproof, Dust-Ignitionproof
120-277 V, 120 V V, 277 V V, 347 V V, 50/60 Hz. For use with Threaded Metal Conduit. Suitable for Wet Locations and Paint Spray Booths.
Class I, Division 1 and 2, Groups C,D
Class II, Division 1 and 2, Groups E,F,G
Class III
Marine Type Electric Fixture Inside Drip-Proof
Type
Applications
• Classified areas where ignitable gases and vapors, dusts,
paint residue, paint powder, or corrosive atmospheres may be
present, or where excessive moisture is a problem.
• Approved for mounting directly inside a paint spray booth.
Complies with NEC 516-3(b) and NFPA No. 33.
• Typical applications include refineries, chemical and
petrochemical plants, textile mills, grain elevators and other
grain-processing facilities, pharmaceutical plants, and paint
spray areas.
Two Lamp APL
Lighting
Lighting: Explosionproof — Area — Fluorescent
Features
• Factory sealed fixture. No external seals needed for
classified areas.
• Two lamp:
— Compact size
— Uses two single-ended biaxial 40 W fluorescent lamps in a
fixture only 29”/736.6 mm long
— Available for 120-277 V, 50/60 Hz
— Available for 120 V, 277 V, 347 V, 50/60 Hz V
• Four lamp:
— Uses four single-ended biaxial 40 W fluorescent lamps
mounted tandem in a 52-1/2”/1333.5 mm long fixture
— Available for 120-277 V, 50/60 Hz
— Available for 120 V, 277 V, 347 V, 50/60 Hz V
• Easy to install. Has three 3/4”/19.1 mm conduit hubs on each
end of fixture. Two close-up plugs per end are furnished.
Mounts straight down, or at 45° angle to either side. Can be
mounted horizontally, or mounted vertically on wall. Gasketed
end caps remove easily for wiring or relamping.
• Explosionproof, heat-resistant and impact-resistant glass
tubes protect lamps.
• Cool-operating fluorescent lamps provide excellent color
rendition and high lumen output per watt. Average lamp life
is 20,000 hours. Lamps are furnished.
• Corrosion resistant.
• Reflector (optional) is designed for efficient distribution.
Installs and removes using only a screwdriver.
• Appleton APL fixtures are supplied with energy-saving Class
P ballasts, equipped with an automatic thermally activated
protective device.
Two Lamp APL with Optional Reflector
Four Lamp APL
Standard Materials
• End housing: copperfree (4/10 of 1% max.) aluminum
• Housing hood and optional reflectors: heavy gauge aluminum
• Wire guard: stainless steel
Four Lamp APL with Optional Reflector
Standard Finishes
• End housings and hood: two-coat baked gray epoxy finish
• Reflector: white baked powder coat polyester reflecting surface
Certifications and Compliances
•
•
•
•
UL Standard: UL 1598, UL 844
UL Listed: E10794
CSA Standard: C22.2 No. 250, C22.2 No. 137
CSA Certified: 025428
Illustrated Feature
APL Fixture shown with explosionproof,
gasketed end caps removed, allowing
access for wiring and relamping.
V CSA Certification only.
1252
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
APL Two and Four Lamp Fluorescent Factory Sealed Luminaires
Explosionproof, Dust-Ignitionproof
120-277 V, 120 V V, 277 V V, 347 V V, 50/60 Hz. For use with Threaded Metal Conduit. Suitable for Wet Locations and Paint Spray Booths.
Class I, Division 1 and 2, Groups C,D
Class II, Division 1 and 2, Groups E,F,G
Class III
Marine Type Electric Fixture Inside Drip-Proof
Type
Lamps
(Included)
Volts
Hub Size
(Inches)
Temperature
Rating
Supply Wire
°F/°C
Catalog
Number
(2) 40 W F40BX
120-277
3/4
T-6
140/60
APL240BU
(2) 40 W F40BX
3477
3/4
T-6
140/60
APL240-347 V
(4) 40 W F40BX
120-277
3/4
T6
140/60
APL440BU
(4) 40W F40BX
347
3/4
T-6
60°C
Luminaires Without Reflector
Two Lamp
Four Lamp
Aluminum reflector with white powder coat polyester finish
Two Lamp
APL2R
Four Lamp
APL4R
Two Lamp
APL-2-GU-SS
Four Lamp
ARS-GU-SS
Wire Guard
Lighting: Explosionproof — Area — Fluorescent
APL440-347 V
Exit Sign — 6” red lettering on white enamel field
Two Lamp Only
APLEXR
Lighting
V CSA Certification only.
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
1253
APL Two Lamp Factory Sealed Luminaire Dimensions and Photometric Data
Explosionproof, Dust-Ignitionproof
120-277 V, 120 V V, 277 V V, 347 V V, 50/60 Hz. For use with Threaded Metal Conduit. Suitable for Wet Locations and Paint Spray Booths.
Dimensions
(3) 3/4" Conduit Holes on
Each End, Furnished with
Two Close-Up Plugs
5.5"/
139.7 mm
22.75"/
577.9 mm
29.00"/
736.6 mm
7.75"/
196.9 mm
8.75"/
222.3 mm
8.75"/
222.3 mm
16.00"/
406.4 mm
End View —With Optional Reflector
Side View — Without Optional Reflector
Lighting
Lighting: Explosionproof — Area — Fluorescent
APL240
Photometric Data
Total Luminaire Efficiency = 81.4%
CIE Type - Direct
Plane
Spacing
Criteria
0-180
1.28
90-270
1.50
Diagonal
1.54
Zone
Lumens
REPORT NUMBER: APL240R
Lamps: Two 40 W Two-Foot Explosionproof Fluorescent
Coefficients of Utilization - Zonal Cavity Method
Effective Floor Cavity Reflectance 0.20
% Ceiling Rcc
% Walls Rw
80
70
50
70
30
10
70
50
50
30
10
50
30
30
10
50
30
10
10
50
30
0
10
0
0 97 97 97 97 95 95 95 95 90 90 90 87 87 87 83 83 83 81
0-10
143.58
1 88 84 81 77 86 82 79 76 79 76 74 76 73 71 73 71 69 68
10-20
422.85
2 80 73 67 62 78 71 66 62 68 64 60 66 62 59 63 60 57 56
20-30
667.66
3 72 64 57 51 70 62 56 51 60 54 50 58 53 49 55 51 48 46
30-40
852.03
4 66 56 49 43 64 55 48 43 53 47 42 51 46 41 49 45 41 39
40-50
948.58
5 61 50 42 37 59 49 42 36 47 41 36 45 40 35 44 39 35 33
50-60
920.43
6 56 44 37 32 54 44 37 31 42 36 31 41 35 31 40 34 31 29
60-70
709.76
7 52 40 33 28 50 39 33 28 38 32 27 37 31 27 36 31 27 25
70-80
373.12
8 48 37 29 24 47 36 29 24 35 29 24 34 28 24 33 28 24 22
80-90
87.31
9 45 33 27 22 43 33 26 22 32 26 22 31 26 22 30 25 21 20
90-100
0.00
10 42 31 24 20 41 30 24 20 29 24 20 29 23 19 28 23 19 18
100-110
0.00
110-120
0.00
Zonal Lumen Summary
120-130
0.00
Zone
Lumens
% Lamp
% Fixture
Zone
Lumens
% Lamp
130-140
0.00
0-30
1234.09
19.6
24.1
90-120
0.00
0.0
140-150
0.00
0-40
2086.12
33.1
40.7
90-130
0.00
0.0
0.0
150-160
0.00
0-60
3955.13
62.8
77.2
90-150
0.00
0.0
0.0
160-170
0.00
0-90
5125.31
81.4
100.0
90-180
0.00
0.0
0.0
170-180
0.00
5125.32
81.4
100.0
0-180
% Fixture
0.0
V CSA Certification only.
1254
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
APL Four Lamp Fluorescent Factory Sealed Luminaire Photometric Data
Explosionproof, Dust-Ignitionproof
120-277 V, 120 V V, 277 V V, 347 V V, 50/60 Hz. For use with Threaded Metal Conduit. Suitable for Wet Locations and Paint Spray Booths.
Total Luminaire Efficiency = 79.9%
REPORT NUMBER: APL440R
Lamps: Four 40 W Explosionproof Fluorescent
CIE Type - Direct
Plane
Spacing
Criteria
0-180
1.30
Coefficients of Utilization - Zonal Cavity Method
90-270
1.50
Effective Floor Cavity Reflectance 0.20
Diagonal
1.54
% Ceiling Rcc
% Walls Rw
Zone
50
70
30
10
70
50
50
30
10
50
30
30
10
50
30
10
10
50
30
0
10
0
Lumens
0 95 95 95 95 93 93 93 93 89 89 89 85 85 85 82 82 82 80
277.70
1 87 83 79 76 85 81 78 75 78 75 73 74 72 70 72 70 68 67
10-20
817.61
2 78 72 66 61 76 70 65 61 67 63 59 65 61 58 62 59 56 55
20-30
1291.05
3 71 62 56 50 69 61 55 50 59 53 49 57 52 48 54 51 47 45
30-40
1648.83
4 65 55 48 42 63 54 47 42 52 46 41 50 45 41 48 44 40 38
40-50
1837.13
5 59 49 41 36 58 48 41 36 46 40 35 45 39 35 43 38 35 33
50-60
1787.64
6 55 44 36 31 53 43 36 31 41 35 31 40 35 30 39 34 30 28
60-70
1379.79
7 51 39 32 27 49 39 32 27 38 31 27 36 31 27 35 30 26 25
70-80
722.47
8 47 36 29 24 46 35 29 24 34 28 24 33 28 24 32 27 24 22
80-90
148.89
9 44 33 26 22 43 32 26 21 31 25 21 31 25 21 30 25 21 20
10 41 30 24 19 40 30 24 19 29 23 19 28 23 19 28 23 19 18
90-100
0.00
100-110
0.00
110-120
0.00
Zonal Lumen Summary
0.00
Zone
Lumens
% Lamp
% Fixture
Zone
Lumens
% Lamp
0.00
0-30
2386.36
19.2
24.1
90-120
0.00
0.0
0.0
140-150
0.00
0-40
4035.19
32.5
40.7
90-130
0.00
0.0
0.0
150-160
0.00
0-60
7659.96
61.8
77.3
90-150
0.00
0.0
0.0
160-170
0.00
0-90
9911.11
79.9
100.0
90-180
0.00
0.0
0.0
170-180
0.00
9911.11
79.9
100.0
0-180
(3) 3/4" Conduit Holes on
Each End, Furnished with
Two Close-Up Plugs
5.5"/139.7 mm
% Fixture
46.63"/
1184.4 mm
52.5"/
1333.5 mm
7.75"/
196.9 mm
8.75"/
222.3 mm
8.75"/
222.3 mm
16.00"/
406.4 mm
Side View — Without Optional Reflector
End View —With Optional Reflector
V CSA Certification only.
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
1255
Lighting
120-130
130-140
Lighting: Explosionproof — Area — Fluorescent
0-10
80
70
EFU Fluorescent Factory Sealed Luminaires
Explosionproof, Dust-Ignitionproof
UNILETS® for use with Threaded Metal Conduit Suitable for use in Wet Locations
Class I, Division 1 and 2, Groups C, D
Class II, Division 1 and 2, Groups E, F, G
Class III
Applications
• Classified areas such as inside paint spray booths, in
pharmaceutical firms, paint-manufacturing plants, printing
plants or any location where ignitable dust, fumes, gases,
paint residue, paint powder or corrosive atmospheres may be
present.
Lighting: Explosionproof — Area — Fluorescent
Features
• Factory sealed unit – no external seals required.
Installation is easy.
• A wide range of ballasts and voltages are available for both
domestic and export applications.
• Three hubs on each end of fixture provide for straight-down
mounting or at 45° to either side. Two close-up plugs furnished
for each end of fixture.
• Explosionproof, impact-resistant and heat-resistant glass tubes
protect lamps.
• Reflectors can easily be removed for replacement or cleaning
using only a screwdriver.
• Appleton EFU fixtures are supplied with Class P ballasts,
equipped with an automatic thermally activated protective
device. They offer protection against excessive voltage, internal
ballast short circuiting, inadequate lamp maintenance and
improper fixture application.
• Non-sparking exterior surfaces for safer operation.
Standard Materials
• Hood, housings and reflectors: copperfree (4/10 of 1% max.)
aluminum
• Hood and housings: gray epoxy finish
• Reflectors: white baked enamel inside and gray epoxy outside
Options
• Emergency battery pack. Suffix -EL.
• Fusing: ARS, AH and AVH fixtures supplied as standard with
Class P ballasts with built-in protective device. Additional
external fusing available at extra cost. Suffix -F.
Lighting
Certifications and Compliances
•
•
•
•
UL Standard: UL 1598, UL 844
UL Listed: E10794
CSA Standard: C22.2 No. 250, C22.2 No. 137
CSA Certified: 025428
Explosionproof caps easily removed
(shown with caps removed) for easy access.
Allows quick wiring or relamping.
1256
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
EFU Fluorescent Factory Sealed Luminaires
Explosionproof, Dust-Ignitionproof
UNILETS® for use with Threaded Metal Conduit Suitable for use in Wet Locations
Class I, Division 1 and 2, Groups C, D
Class II, Division 1 and 2, Groups E, F, G
Class III
Lamp
Volts
Two Lamps
Rapid Start VHO-SHO
T-12 Recessed Double Contact
48” 1500MA
Catalog
Number ➋
120-277 V, 50/60 Hz
3/4
T-6
140/60 ARS232-BU ➊
347 V, 60 Hz
3/4
T-6
140/60 ARS232-347 V➊
120-277 V, 50/60 Hz
3/4
T-6
140/60 ARS240-BU ➊
347 V, 60 Hz
3/4
T-6
140/60 ARS240-347 V➊
120-277 V, 50/60 Hz
3/4
T-6
140/60 AH260-BU
347 V, 60 Hz
3/4
T-6
140/60 AH260-347 V
120 V, 60 Hz
277 V, 60 Hz
347 V, 60 Hz
3/4
3/4
3/4
T-6
T-6
T-6
140/60 AVH210-118
140/60 AVH210-277
140/60 AVH210-347 V
120-277 V, 50/60 Hz
3/4
T-6
140/60 ARS332-BU ➊
347 V, 60 Hz
3/4
T-6
140/60 ARS332-347 V➊
120-277 V, 50/60 Hz
3/4
T-6
140/60 ARS340-BU
347 V, 60 Hz
3/4
T-6
140/60 ARS340-347 V
120-277 V, 50/60 Hz
3/4
T-6
140/60 AH360-BU
347 V, 60 Hz
3/4
T-6
140/60 AH360-347 V
120-277 V, 50/60 Hz
3/4
T-6
140/60 ARS432-BU ➊
347 V, 60 Hz
3/4
T-6
140/60 ARS432-347 V➊
120-277 V, 50/60 Hz
3/4
T-6
140/60 ARS440-BU
347 V, 60 Hz
3/4
T-6
140/60 ARS440-347 V
120-277 V, 50/60 Hz
3/4
T-6
140/60 AH460-BU
347 V, 60 Hz
3/4
T-6
140/60 AH460-347 V
120 V, 60 Hz
277 V, 60 Hz
347 V, 60 Hz
3/4
3/4
3/4
T-6
T-6
T-6
140/60 AVH410-118
140/60 AVH410-277
140/60 AVH410-347 V
Three Lamps
32 W
Rapid Start
T8 Bi-Pin
48” 265MA
40 W
Rapid Start
T12 Bi-Pin
48” 430MA
60 W
Rapid Start High Output
T-12 Recessed Double Contact
48” 800MA
Lighting: Explosionproof — Area — Fluorescent
32 W
Rapid Start
T8 Bi-Pin
48” 265MA
40 W
Rapid Start
T12 Bi-Pin
48” 430MA
60 W
Rapid Start High Output
T-12 Recessed Double Contact
48” 800MA
110 W
Hub Size Temperature Supply Wire
(Inches)
Rating
°F/°C
Four Lamps
Rapid Start Very High Output
T-12 Recessed Double Contact
48” 1500MA
Protector for two-lamp fluorescent fixture
Fits two lamp 48” fixtures only (ARS, AH and AVH series)
UV stabilized polycarbonate.
EFP248
NOTE: In paint spray areas, solvents and thinners may “cloud” the polycarbonate. Light transmission characteristics may be reduced.
➊ For Emergency Battery Pack, add suffix -EL.
➋ Fluorescent lamps are not included. Supplied with automatic resetting dual protected “Class P” ballast. For additional external fusing, add suffix -F.
V CSA Certification only.
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
1257
Lighting
32 W
Rapid Start
T8 Bi-Pin
48” 265MA
40 W
Rapid Start
T12 Bi-Pin
48” 430MA
60 W
Rapid Start High Output
T-12 Recessed Double Contact
48” 800MA
110 W
EFU Fluorescent Factory Sealed Luminaire Ballast Data and Dimensions
Explosionproof, Dust-Ignitionproof
UNILETS® for use with Threaded Metal Conduit Suitable for use in Wet Locations
Catalog
Number
Lamps
Hz
Voltage
Operating
Amps
Input
Watts
Starting Temperature
°F/°C
Lighting: Explosionproof — Area — Fluorescent
32 W Rapid Start T-8 Bi-Pin 48” 265 mA
ARS232-BU
2
50/60
120-277
.52-.22
62-60
0/-18
ARS232-347 V
2
60
347
.20
59
0/-18
ARS332-BU
3
50/60
120-277
.78-.33
93-93
0/-18
ARS332-347 V
3
60
347
.30
86
0/-18
ARS432-BU
4
50/60
120-277
1.03-.43
124-120
0/-18
ARS432-347 V
4
60
347
.40
118
0/-18
50/60
120-277
.70-.35
84-42
50/10
40 W Rapid Start T-12 Bi-Pin 48” 430 mA
ARS240-BU
2
ARS240-347 V
2
60
347
.30
96
50/10
ARS340-BU
3
50/60
120-277
.99-.45
114
50/10
ARS340-347 V
3
60
347
.50
140
50/10
ARS440-BU
4
50/60
120-277
1.40-.70
168-84
50/10
ARS440-347 V
4
60
347
.60
192
50/10
120-277
1.05-.55
122-86
-20/-29
60 W Rapid Start High Output T-12 Bi-Pin 48” 800 mA
AH260-BU
2
50/60
AH260-347 V
2
60
347
.50
145
-20/-29
AH360-BU
3
50/60
120-277
1.54-.66
182
-20/-29
AH360-347 V
3
60
347
.90
256
-20/-29
AH460-BU
4
50/60
120-277
2.10-1.10
244-172
-20/-29
AH460-347 V
4
60
347
1.00
290
-20/-29
AVH210-118
2
60
120
2.60
300
-20/-29
AVH210-277
2
60
277
.98
250
-20/-29
AVH210-347 V
2
60
347
.90
250
-20/-29
AVH410-118
4
60
120
5.20
600
-20/-29
AVH410-277
4
60
277
1.96
500
-20/-29
AVH410-347 V
4
60
347
1.80
500
-20/-29
Dimensions in In/mm
6.00"/
152.4 mm
6.00"/
152.4 mm
Lighting
110 W Rapid Start VHO-SHO T-12 Bi-Pin 48” 1500 mA
8.75"/
222.3 mm
4.00"/101.6 mm
No. of Lamps
1258
A
B
C
D
E
2
46-5/8/1184.4
52-7/16/1332.0
8-3/4/222.3
5-1/2/139.7
15/381.0
3
46-5/8/1184.4
52-7/16/1332.0
8-3/4/222.3
5-1/2/139.7
19-1/4/489.0
4
46-5/8/1184.4
52-7/16/1332.0
11-7/16/290.6
14/355.6
23-1/2/596.9
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
EFU Fluorescent Factory Sealed Luminaire Photometric Data
Explosionproof, Dust-Ignitionproof
UNILETS® for use with Threaded Metal Conduit Suitable for use in Wet Locations
* Data is based on F32 TB Rapid Start
Lamps. For other lamps use the following
multipliers: 60 W Cool White – 1.50; and 110
W VHO – 2.19. Candlepower distribution
curves and other coefficients of utilization
tables are available on request.
Zone
Lumens
Total Luminaire Efficiency = 78.6%
0-10
10-20
20-30
139.50
402.70
620.06
CIE Type - Direct
30-40
767.75
0-180
1.28
40-50
821.07
90-270
1.36
50-60
776.93
Diagonal
1.44
60-70
597.35
70-80
80-90
299.18
57.43
Zone
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
Lumens
Plane
Zonal Lumen Summary
Zone
0-30
0-40
0-60
0-90
90-120
90-130
90-150
90-180
0-180
Lumens % Lamp % Fixture
1162.26 20.4
25.9
1930.01 33.9
43.1
3528.01 61.9
78.7
4481.97 78.6
100.0
0.00
0.0
0.0
0.00
0.0
0.0
0.00
0.0
0.0
0.00
0.0
0.0
4481.97 78.6
100.0
Total Luminaire Effieciency = 96.8%
CIE Type - Direct
249.94
726.14
1122.12
30-40
1392.92
0-180
1.26
40-50
1496.9
90-270
1.38
50-60
1397.8
Diagonal
1.46
60-70
1087.36
70-80
80-90
557.01
103.54
Lumens
Spacing
Criteria
Plane
Zonal Lumen Summary
Zone
0-30
0-40
0-60
0-90
90-120
90-130
90-150
90-180
0-180
Lumens % Lamp % Fixture
2098.20 25.0
25.8
3491.12 41.6
42.9
6385.81 76.0
78.5
8133.73 96.8
100.0
0.00
0.0
0.0
0.00
0.0
0.0
0.00
0.0
0.0
0.00
0.0
0.0
8133.73 96.8
100.0
Total Luminaire Effieciency = 70.9%
CIE Type - Direct
237.58
692.75
1081.02
30-40
1352.75
0-180
1.28
40-50
1467.39
90-270
1.42
50-60
1408.53
Diagonal
1.48
60-70
1130.45
70-80
80-90
598.78
117.42
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
Spacing
Criteria
Plane
1
2
3
4
5
6
7
8
9
10
Zone
0-30
0-40
0-60
0-90
90-120
90-130
90-150
90-180
0-180
Lumens % Lamp % Fixture
2011.34 17.6
24.9
3364.10 29.5
41.6
6240.02 54.7
77.2
8086.66 70.9
100.0
0.00
0.0
0.0
0.00
0.0
0.0
0.00
0.0
0.0
0.00
0.0
0.0
8086.66 70.9
100.0
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
70
50
30
10
0
70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10
0
86
78
71
65
59
55
51
47
44
41
82
71
62
55
49
44
40
36
33
31
78
66
56
48
42
37
33
29
27
24
75
61
51
43
36
32
28
25
22
20
83
76
69
63
58
53
49
46
43
40
80
70
61
54
48
43
39
36
33
30
77
65
55
47
41
36
32
29
26
24
74
60
50
42
36
32
28
25
22
20
77
67
59
52
46
42
38
35
32
29
74
63
53
46
40
36
32
29
26
24
72
59
49
42
36
31
28
24
22
20
74
64
56
50
45
40
37
34
31
29
72
61
52
45
40
35
31
28
26
23
70
58
48
41
35
31
27
24
22
20
71
62
54
48
43
39
36
33
30
28
69
59
51
44
39
34
31
28
25
23
68
56
47
41
35
31
27
24
22
20
66
55
46
39
33
29
25
23
20
18
REPORT NUMBER: ARS332
Lamps: Three 32 W Explosionproof Fluorescent with Reflector *
Coefficients of Utilization - Zonal Cavity Method
Effective Floor Cavity Reflectance 0.20
% Ceiling Rcc
80
70
50
30
10
0
70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10
0
0 115 115 115 115 113 113 113 113 108 108 108 103 103 103 99 99 99 97
1
2
3
4
5
6
7
8
9
10
105 101
96 87
87 77
79 68
73 60
67 54
62 49
58 44
54 41
50 38
97
81
69
59
51
45
40
36
33
30
93
75
62
52
45
39
34
30
27
25
103
93
84
77
71
65
60
56
53
49
99
86
75
66
59
53
49
44
40
37
95
80
68
58
51
45
40
36
32
30
91
74
62
52
45
39
34
30
27
25
94
82
72
64
57
51
47
42
39
36
91
77
66
57
50
44
39
35
32
29
88
73
60
51
44
38
34
30
27
24
91
79
69
62
55
50
45
41
38
35
88
75
64
55
49
43
38
35
31
29
86
71
59
50
44
38
34
30
27
24
87
76
67
59
53
48
44
40
37
34
85
72
62
54
48
42
38
34
31
28
83
69
58
50
43
38
33
30
27
24
81
67
56
48
41
36
31
28
25
22
REPORT NUMBER: ARS432
Lamps: Four 32 W Explosionproof Fluorescent with Reflector *
Coefficients of Utilization - Zonal Cavity Method
Effective Floor Cavity Reflectance 0.20
% Ceiling Rcc
% Walls Rw
Zonal Lumen Summary
80
0 94 94 94 94 91 91 91 91 87 87 87 84 84 84 80 80 80 79
% Walls Rw
0-10
10-20
20-30
90-100
100-110
110-120
120-130
130-140
140-150
150-160
160-170
170-180
Effective Floor Cavity Reflectance 0.20
% Ceiling Rcc
80
70
50
30
10
0
70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10
0
0 84 84 84 84 82 82 82 82 79 79 79 75 75 75 72 72 72 71
1 77 74 70 68 75 72 69 67 69 67 64 66 64 62 64 62 61 59
2
3
4
5
6
7
8
9
10
70
63
58
53
49
45
42
39
37
64
56
49
44
39
35
32
29
27
59
50
43
37
33
29
26
23
21
55
45
38
32
28
24
22
19
18
68
62
56
51
47
44
41
38
36
62
54
48
43
38
35
32
29
27
58
49
42
37
32
29
26
23
21
54
44
37
32
28
24
22
19
17
60
52
46
41
37
34
31
28
26
56
48
41
36
32
28
25
23
21
53
44
37
32
27
24
21
19
17
57
50
45
40
36
33
30
27
25
54
46
40
35
31
28
25
23
21
51
43
36
31
27
24
21
19
17
55
48
43
38
35
32
29
27
25
53
45
39
34
30
27
24
22
20
50
42
36
31
27
24
21
19
17
49
41
34
29
25
22
20
18
16
1259
Lighting
Zone
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
Coefficients of Utilization - Zonal Cavity Method
% Walls Rw
0-10
10-20
20-30
90-100
100-110
110-120
120-130
130-140
140-150
150-160
160-170
170-180
REPORT NUMBER: ARS232
Lamps: Two 32 W Explosionproof Fluorescent with Reflector *
Lighting: Explosionproof — Area — Fluorescent
90-100
100-110
110-120
120-130
130-140
140-150
150-160
160-170
170-180
Spacing
Criteria
PAPL Portable Two and Four Lamp Fluorescent Factory Sealed Luminaire
Explosionproof, Dust-Ignitionproof
120 V. Suitable for Wet Locations and Paint Spray Booths. UL Listed for Horizontal use only.
Class I, Division 1 and 2, Groups C, D
Applications
• Classified areas where ignitable gases and vapors, dusts,
paint residue, paint powder, or corrosive atmospheres may be
present, or where excessive moisture is a problem.
• Approved for using directly inside a paint-spray booth.
Complies with NEC 516-3(c) and NFPA No. 33.
• Typical applications include aircraft manufacturing and
maintenance facilities, refineries, chemical and petrochemical
plants, textile mills, grain elevators and other grain-processing
facilities, pharmaceutical plants, paint-spray areas, and where
the permanent mounting of a fixture is not practical.
• UL approved for horizontal use only.
Lighting
Lighting: Explosionproof — Area — Fluorescent
Features
• Factory sealed fixture. No external seals needed for
classified areas.
• Compact size. Uses two or four single-ended biaxial 40 W
fluorescent lamps in a portable fixture. (2 lamp cart overall
length is 38-1/2”/978 mm, 4 lamp cart overall length is 62”).
• Gasketed end caps remove easily for wiring and relamping.
• Teflon-coated stainless steel wire guard supplied standard.
• Adjustable aluminum mounting frame allows fixtures to pivot at
45° increments in a 180° horizontal plane.
• 50’ of 16-3 SOW cord with nonmetallic explosionproof plug
prewired for 120 V.
• Static discharge wheels.
• Explosionproof, heat-resistant and impact-resistant glass tubes
help protect the lamp.
• Cool-operating fluorescent lamps provide excellent color
rendition and high lumen output per watt. Average lamp life is
20,000 hours.
• Corrosion resistant.
• Reflectors (optional) are designed for efficient distribution.
Easily installed using only a screwdriver.
• Energy-saving Class P ballasts, with automatic thermally
activated protective device.
• Fixture uses Appleton’s ECP1523 Plug, which is UL Classified
for use with Killark® UGR and Crouse-Hinds® ENR series
receptacles, as well as Appleton’s U-Line receptacles.
4-Lamp Luminaire
2-Lamp Luminaire
Standard Materials
• End housing, cord grip and elbow: copperfree (4/10 of 1%
max.) aluminum
• Housing hood, frame and optional reflectors: heavy gauge
aluminum
• Wheels: static discharge rubber
• Guard: Teflon coated stainless steel
• Plug: aluminum
Standard Finishes
• End housings and hood: two-coat baked gray epoxy finish
• Reflector: white baked powder coat polyester
• Frame assembly: natural aluminum
Certifications and Compliances
•
•
•
•
UL Standard: UL 1598, UL 844
UL Listed: E59147
CSA Standard: C22.2 No. 12, C22.2 No. 137
cUL Listed: E59147
1260
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
PAPL Portable Two and Four Lamp Fluorescent Factory Sealed Luminaire
Explosionproof, Dust-Ignitionproof
120 V. Suitable for Wet Locations and Paint Spray Booths. UL Listed for Horizontal use only.
Class I, Division 1 and 2, Groups C, D
Lamps
Included
Volts
Temperature
Rating
Catalog
Number
T6
PAPL240-120
Two-Lamp Luminaires Less Reflector
(2) 40 W F40BX
120
Reflector Only
Aluminum reflector with white powder coat polyester finish
APL2R
(4) 40 W F40BX
Two-Lamp Luminaire Illustrated
120
T6
PAPL440-120
Reflector Only
Aluminum reflector with white powder coat polyester finish
APL4R
Dimensions in Inches/Millimeters
18.00"/
457.2 mm
13.88"/
352.6 mm
Lighting: Explosionproof — Area — Fluorescent
Four-Lamp Luminaires Less Reflector
8.50"/
215.9 mm
5.00"/
127.0 mm
Dia.
Lighting
14.00"/
355.6 mm
18.00"/
457.2 mm
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
62.00"/1574.8 mm 4 Lamp
38.50"/977.9 mm 2 Lamp
1261
FD Series Cylindrical Fluorescent Luminaires
Standard and Emergency Battery Back-Up – Flameproof
Zone 1 & 2 – 21 & 22
II 2 GD
ATEX / IECEx
IP66/68
Applications
• Can be installed in hazardous areas designated as Zone 1, 2, 21
and 22.
• For use in locations where a high degree of corrosion resistance
is required.
• For indoor/outdoor use where protection against dirt, water and
moisture is necessary.
• Typical applications include oil refineries, petrochemical
facilities, pulp and paper, mills, painting, sewage and water
treatment facilities, warehouses, underground tunnels and
general manufacturing facilities.
2 x 58 W
Lighting: Explosionproof — Area — Fluorescent
Features
• Impact resistant borosilicate glass sealed tube.
• Easy access to lamps through gray painted Zamak
threaded entry cap.
• Supplied with O-ring for improved ingress protection.
• Corrosion-resistant gray painted Zamak.
• Supplied with energy efficient and self induction ferromagnetic
ballast on a removable gear tray.
• Quick and easy installation of fluorescent lighting fixtures with
2G11 and G13 lamp holders.
• Supplied with external and internal ground/earth connection.
• Fixture supplied with one M20 blanking plug.
• Easy connection to wire and disconnect with plug-in
terminal blocks.
• Bi-pin (G13) 18 & 36 W magnetic ballast versions operate at
158°F/70°C ambient temperature with T4 rating.
• Magnetic ballast versions 230 V 50 Hz or 240 V 50 Hz or 220 V
60 Hz or 230 V 60 Hz.
• Electronic ballast versions 110 to 254 Vac/Vdc 50/60 Hz.
• 3 hour emergency version with automatic self test every month
• Plug in battery pack (6 V 4 Ah) is easy to remove for
maintenance.
Lighting
Standard Materials
•
•
•
•
•
End caps and cover: gray painted Zamak
Glass tube: borosilicate
O-ring gasket: Nitrile (NBR)
Internal reflector: white powder coated galvanized steel
Mounting accessories: several accessories in different material
such as zinc plated steel, galvanized steel or 316 stainless steel
Options
• 3 lamp versions.
• 8 W fluorescent (Bi-pin G5) available, see section HBDC series.
1262
2 x 36 W
2 x 18 W
Certifications and Compliances
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
Certification Type: FLd
Zone 1 and 2
— Conforming to ATEX 94/9/CE: CE 0081
II 2 G
— ATEX/IEC Protection: Ex d IIB, Ex d IIB+H2, Ex d IIC
— T Rating: (See table)
Zone 21 and 22
II 2 D
— Conforming to ATEX 94/9/CE: CE
— ATEX/IEC Protection: Ex tD A21
— Surface Temperature: (See table)
Ambient Temperature: -4°F to 131°F / -20°C to 55°C
CE Declaration of Conformity: 50203
ATEX Certificate: LCIE 97 ATEX 6012
IECEx Certificate: IECEx LCI 04.0018
Other Certifications: GOST
Index of Protection (solid & liquid): IP66/68
Impact Resistance (shock): IK08
Internal Volume: > 122.05in3/2 dm3 (2 liters)
Ex Standards: EN / IEC 60079-0; 60079-1; 61241-0; 61241-1
Product Standards: EN / IEC 60598-1; 60598-2-22
EMC Standards: EN / IEC 55015; 61547
Other Standards: EN / IEC 60529 (IP); 62262 (IK)
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
FD Series Cylindrical Fluorescent Luminaires
Standard and Emergency Battery Back-Up – Flameproof
Zone 1 & 2 – 21 & 22
II 2 GD
ATEX / IECEx
IP66/68
Ordering Information
Order using catalog numbering guide below or select catalog number from tables on following pages.
Catalog Numbering Guide For Fd Non-Metallic Fluorescent Lighting Fixtures
FD
B
Series:
FD - FD Series
Zone 1 & 2 - 21 & 22
ATEX / IEC certified
1
18
Number of Lamps:
1 - Single
2 - Double
3 - Three Lamps
BK
A
P
Options:
(Options must be
listed alphabetically)
E - 3h Emergency
(combined) –
Battery 6 V 4 Ah
Emergency versions:
BU - 110 to 254 Vac/Vdc
50/60 Hz
Lamp Type:
B - Bi-pin (G13) Fluorescent
C - Compact Fluorescent (2G11)
F - Bi-pin (G5) Fluorescent
Cable Entry:
M - Metric M20
N - NPT 3/4"
Wattage:
18 - 18 Watt
36 - 36 Watt
58 - 58 Watt
T Rating (Gas) and Surface Temperature (Dust) Table
Model
0.3
1.2
1.5
Dust – Surface Temperature
Without
External
Reflector
With
External
Reflector
Compact Fluorescent 2G11
18 W max.
T6
T5
N.A.
T5
T4
203 °F/95 °C 266 °F/130 °C
a) Fluorescent G13
Magnetic Ballast
1 x 18 W / 2 x 18 W
T6
T5
T4
T6
T5
207 °F/97 °C 203 °F/95 °C
b) Fluorescent G13
Electronic Ballast
1 x 18 W / 2 x 18 W / 3 x 18 W
T6
T6
N.A.
T6
T5
172 °F/78 °C 203 °F/95 °C
c) Compact Fluorescent 2G11
1 x 36 W
2 x 36 W
T6
T5
N.A.
T6
T5
T4
203 °F/95 °C 266 °F/130 °C
a) Fluorescent G13
Magnetic Ballast
1 x 36 W / 2 x 36 W / 3 x 36 W
T6
T5
T4
T6
T5
230 °F/110 °C 203 °F/95 °C
b) Fluorescent G13
Electronic Ballast
1 x 36 W / 2 x 36 W / 3 x 36 W
T6
T6
N.A.
T6
T6
172 °F/78 °C 176 °F/80 °C
a) Fluorescent G13
Magnetic Ballast
1 x 58 W / 2 x 58 W
T6
T6
N.A.
T6
T5
176 °F/80 °C 203 °F/95 °C
b) Fluorescent G13
Electronic Ballast
1 x 58 W / 2 x 58 W / 3 x 58 W
T6
T5
N.A.
T6
T5
183 °F/84 °C 203 °F/95 °C
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
1263
Lighting
0.6
Lamp Type
Gas – T Rating
Without External Reflector
With External Reflector
Ta =
Ta =
Ta =
Ta =
Ta =
104° F/40° C 131 °F/55 °C 158 °F/70 °C 104 °F/40 °C 131 °F/55 °C
Lighting: Explosionproof — Area — Fluorescent
Voltage (50/60 Hz):
Standard versions:
AA - 220 Vac 60 Hz
AC - 230 Vac 60 Hz
XC - 230 Vac 50 Hz
X3 - 240 Vac 50 Hz
BU - 110 to 254 Vac/Vdc
50/60 Hz
FD Series Cylindrical Fluorescent Luminaires
Standard and Emergency Battery Back-Up – Flameproof
Zone 1 & 2 – 21 & 22
II 2 GD
ATEX / IECEx
IP66/68
Ordering Information – Standard Versions
Two M20 threaded entries, supplied with one M20 aluminum blanking plug.
Connection via 1 x 3 double deck terminals.
Capacity (flexible/solid): 0.001 in2 to 0.004 in2 / 0.75 mm2 to 2.5 mm2.
L
For Bi-pin (G13) Fluorescent Lamps - T8 (1.02"/26 mm) or T12 (1.50"/38 mm)
230 V - 50 Hz – Magnetic Ballast – Starter Ignition
Compensated power supply – power factor > 0.9
L
Lighting: Explosionproof — Area — Fluorescent
No. of
Lamps
Power
(W)
Gas
Group
Model
L
N
N
N
Weight
(lbs/kg)
Volume
(in3/dm3)
Pack
Catalog
Number
1
18
IIC
0.6
19.8/9
3539.38/58
1
FDB118XCM
2
18
IIC
0.6
21.38/9.7
3539.38/58
1
FDB218XCM
1
36
IIB+H2
1.2
32.41/14.7
6041.35/99
1
FDB136XCM
2
36
IIB+H2
1.2
33.73/15.3
6041.35/99
1
FDB236XCM
1
58
IIB
1.5
37.48/17
7261.83/119
1
FDB158XCM
2
58
IIB
1.5
40.12/18.2
7261.83/119
1
FDB258XCM
240 V - 50 Hz – Magnetic Ballast – Starter Ignition
Compensated power supply – power factor > 0.9
1
18
IIC
0.6
19.8/9
3539.38/58
1
FDB118X3M
2
18
IIC
0.6
21.38/9.7
3539.38/58
1
FDB218X3M
1
36
IIB+H2
1.2
32.41/14.7
6041.35/99
1
FDB136X3M
2
36
IIB+H2
1.2
33.73/15.3
6041.35/99
1
FDB236X3M
1
58
IIB
1.5
37.48/17
7261.83/119
1
FDB158X3M
2
58
IIB
1.5
40.12/18.2
7261.83/119
1
FDB258X3M
3539.38/58
1
FDB218AAM
220 V - 60 Hz – Magnetic Ballast – Starter Ignition
Lighting
Compensated power supply – power factor > 0.9
2
18
IIC
0.6
21.38/9.7
2
36
IIB+H2
1.2
33.73/15.3
6041.35/99
1
FDB236AAM
2
58
IIB
1.5
40.12/18.2
7261.83/119
1
FDB258AAM
230 V - 60 Hz – Magnetic Ballast – Starter Ignition
Compensated power supply – power factor > 0.9
1264
2
18
IIC
0.6
21.38/9.7
3539.38/58
1
FDB218ACM
2
36
IIB+H2
1.2
33.73/15.3
6041.35/99
1
FDB236ACM
2
58
IIB
1.5
40.12/18.2
7261.83/119
1
FDB258ACM
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
FD Series Cylindrical Fluorescent Luminaires
Standard and Emergency Battery Back-Up – Flameproof
Zone 1 & 2 – 21 & 22
II 2 GD
ATEX / IECEx
IP66/68
Ordering Information – Standard Versions – Continued
L
For Bi-pin (G13) Fluorescent Lamps - T8 (1.02"/26 mm) or T12 (1.50"/38 mm)
110 to 254 Vac/Vdc 50/60 Hz – Electronic Ballast
Power factor > 0.95
L
L
N
N
N
Power
(W)
Gas
Group
Model
Weight
(lbs/kg)
Volume
(in3/dm3)
Pack
Catalog
Number
2
18
IIC
0.6
21.38/9.7
3539.38/58
1
FDB218BUM
2
36
IIB
1.2
33.73/15.3
6041.35/99
1
FDB236BUM
3
36
IIB
1.2
35.94/16.3
6041.35/99
1
FDB336BUM
1
58
IIB
1.5
37.48/17
7261.83/119
1
FDB158BUM
2
58
IIB
1.5
40.12/18.2
7261.83/119
1
FDB258BUM
3
58
IIB
1.5
42.33/19.2
7261.83/119
1
FDB358BUM
For 2G11 Compact Fluorescent Lamps – TC-L
230 V - 50 Hz – Magnetic Ballast – Starter Ignition
Compensated power supply – power factor > 0.9 – Lamps supplied
1
18
IIC
0.3
19.8/9
3539.38/58
1
FDC118XCM
2
18
IIC
0.3
21.38/9.7
3539.38/58
1
FDC218XCM
1
36
IIB+H2
0.6
32.41/14.7
6041.35/99
1
FDC136XCM
2
36
IIB+H2
0.6
33.73/15.3
6041.35/99
1
FDC236XCM
Emergency Versions
Two M20 threaded entries, supplied with one M20 aluminum blanking plug.
Connection via 1 x 4 double deck terminals.
Capacity (flexible/solid): 0.001 in2 to 0.004 in2 / 0.75 mm2 to 2.5 mm2.
Lighting
For Bi-pin (G13) Fluorescent Lamps – T8 (1.02"/26 mm) or T12 (1.50"/38 mm)
110 to 254 Vac/Vdc 50/60 Hz – Electronic Ballast
3 hour duration - battery pack 6 V 4 Ah - Power factor > 0.95 -
Self test every month.
No. of
Lamps
Power
(W)
Gas
Group
Model
Line
Output
Weight
(lbs/kg)
Volume
(in3/dm3)
Pack
Catalog
Number
2
18
IIC
0.6
29%
25.57/11.6
3539.38/58
1
FDB218BUME
2
36
IIB
1.2
16%
37.92/17.2
6041.35/99
1
FDB236BUME
2
58
IIB
1.5
11%
44.53/20.2
7261.83/119
1
FDB258BUME
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
Lighting: Explosionproof — Area — Fluorescent
No. of
Lamps
1265
FD Series Cylindrical Fluorescent Luminaires
Standard and Emergency Battery Back-Up – Flameproof
Zone 1 & 2 – 21 & 22
II 2 GD
ATEX / IECEx
IP66/68
Description
Pack
Catalog Number
1
FDER1G
External Reflector – White Painted Galvanized Steel
Model 0.3
Model 0.6
1
FDER2G
Model 1.2
1
FDER3G
Model 1.5
1
FDER4G
1
FDPG1Z
Protective Guard – Zinc Plated Steel
Lighting: Explosionproof — Area — Fluorescent
Model 0.3
Model 0.6
1
FDPG2Z
Model 1.2
1
FDPG3Z
Model 1.5
1
FDPG4Z
Zinc plated steel
1
FDFBZ
316 stainless steel
1
FDFBS
Zinc plated steel
1
FDSBZ
316 stainless steel
1
FDSBS
Zinc plated steel
1
FDHC49Z
316 stainless steel
1
FDHC49S
Fixing Brackets for Ease of Surface Installation – Set of Two
Surface Mounting Brackets – Set of Two
Half Clamp Brackets for Pole Mounting – Set of Two
Dia. 1.65 to 1.93" / 42 to 49 mm pole
(1.25 to 1.5" / 31.8 to 38.1 mm tube)
Lighting
Dia. 2.36"/60 mm pole (2"/50.8mm tube)
Zinc plated steel
1
FDHC60Z
316 stainless steel
1
FDHC60S
1.20 M stainless steel chain
1
FDSCS
Fall Prevention Kit
1266
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
FD Series Cylindrical Fluorescent Luminaire Technical Data
Standard and Emergency Battery Back-Up – Flameproof
Zone 1 & 2 – 21 & 22
II 2 GD
ATEX / IECEx
IP66/68
Wiring Diagram
Emergency Function Diagram
Two Lamp Version
Mains
PE
N
L
Mains
Lighting
Switch
Lighting Switch ON
Lighting Switch OFF
ON
L1
Standard Fluorescent
Lighting Fixture
L1
L
N
PE
Emergency Fluorescent
Lighting Fixture
OFF
Lighting: Explosionproof — Area — Fluorescent
L
N
PE
LED Status
Color
Indication
Blinking 1:1
Green
Red
ON
Mains good, battery trickle charging
Blinking 1:1
No battery connected or something is defective
Flashing 1:1
Mains faulty, battery empty or lamp defective
ON
Mains faulty, output ON
OFF
No mains, battery completely empty
Blinking 1:1
Mains good, performing self test
ON
Result of self test was not good
Lighting
Yellow
Function
Mains good, battery quick charging
Dimensions (in/mm)
0.47”/
12.0 mm
0.59”/
15.0 mm
3.05”/
77.5mm
Model
A
B
0.3
16.93" / 430 mm
13.19" / 335 mm
0.6
29.33" / 745 mm
25.59" / 650 mm
1.2
53.74" / 1365 mm
49.61" / 1260 mm
1.5
65.16" / 1655 mm
61.42" / 1560 mm
3.50”/
3.35”/
89.0 mm 85.0 mm
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
1267
FD Series Cylindrical Fluorescent Luminaire Photometric Data
Standard and Emergency Battery Back-Up – Flameproof
Photometric Data
Polar curves for a 1000 lm flux, according to NF C 71-120
Luminaire symbol according to NF C 71-121
Longitudinal
Transverse
Bi-pin (G13) Fluorescent
1 x 18 W
Efficiency 75.3%
NF C 71-121/0: 0.69 H + 0.06 T
Lighting
Lighting: Explosionproof — Area — Fluorescent
Candela
Distribution
0
5
10
15
20
25
30
35
40
45
50
55
60
65
70
0-180 90-270 150° 120°
167
167
Degrees
166
167
164
168
160
168
154
168
147
168
139
167
129
166
118
164
151
162
106
160
77
157
61
152
45
144 0°
15°
28
135
105°
90°
75°
60°
45°
30°
105°
90°
75°
60°
45°
30°
1 x 58 W
Efficiency 74.5%
NF C 71-121/0: 0.70 H + 0.05 T
0-180 90-270
167
167 150° 120°
167
167
Degrees
164
167
160
167
154
167
147
166
139
165
130
164
119
163
106
161
93
158
78
155
63
149 0°
15°
47
142
31
132
1268
0-180 90-270 150° 120°
161
161
Degrees
160
162
157
163
153
164
148
164
141
164
133
164
123
163
112
130
100
153
86
147
73
141
58
134
41
121 0°
15°
26
106
105°
90°
75°
60°
45°
30°
Candela
Distribution
0-180 90-270 150° 120°
0
149
149
Degrees
5
148
149
10
146
150
15
142
150
20
137
150
25
131
149
30
124
148
35
114
146
40
104
144
45
93
138
50
81
131
55
68
125
60
54
117
65
40
105 0°
15°
70
26
91
105°
90°
75°
60°
45°
30°
Candela
Distribution
0-180 90-270
0
148
148 150° 120°
5
147
149
Degrees
10
145
148
15
142
149
20
137
150
25
131
149
30
124
148
35
115
146
40
105
144
45
94
140
50
82
134
55
69
128
60
55
119 0°
15°
65
42
108
70
28
95
0
5
10
15
20
25
30
35
40
45
50
55
60
65
70
Candela
Distribution
0-180 90-270 165° 135° 120°
141
141
Degrees
105°
141
141
141
139
90°
140
135
75°
139
130
138
124
60°
136
117
133
109
45°
128
100
121
89
113
77
105
65
30°
96
51
15°
87
38 0°
78
25
3 x 36 W
Efficiency 53.3%
NF C 71-121: 0.47 G + 0.06 T
105°
90°
75°
60°
45°
30°
2 x 36 W
Efficiency 61.5%
NF C 71-121: 0.57 G + 0.04 T
Candela
Distribution
0
5
10
15
20
25
30
35
40
45
50
55
60
65
70
0
5
10
15
20
25
30
35
40
45
50
55
60
65
70
2 x 18 W
Efficiency 56.2%
NF C 71-121: 0.52 G + 0.04 T
Candela
Distribution
2 x 36 W
Efficiency 61.5%
NF C 71-121: 0.57 G + 0.04 T
Candela
Distribution
0-180 90-270 150° 120°
164
164
Degrees
163
164
161
165
157
165
151
165
145
165
137
165
127
164
116
162
104
160
91
158
76
154
61
149
45
140 0°
15°
30
131
3 x 18 W
Efficiency 57%
NF C 71-121: 0.50 G + 0.07 T
Candela
Distribution
1 x 36 W
Efficiency 74.3%
NF C 71-121/0: 0.69 H + 0.05 T
0
5
10
15
20
25
30
35
40
45
50
55
60
65
70
2G11 Compact Fluorescent
2 x 18 W
Efficiency 68.1%
NF C 71-121: 0.63 G + 0.06 T
0
5
10
15
20
25
30
35
40
45
50
55
60
65
70
0-180 90-270 150° 120°
154
154
Degrees
153
154
151
154
147
153
142
153
136
152
128
150
119
147
108
142
95
143
81
127
66
113
49
101
32
88 0°
15°
17
75
105°
90°
75°
60°
45°
30°
2 x 36 W
Efficiency 53.6%
NF C 71-121: 0.50 G + 0.04 T
Candela
Distribution
0-180 90-270 165° 135° 120°
0
132
132
Degrees
105°
5
132
131
10
132
129
90°
15
131
126
75°
20
131
122
25
131
116
60°
30
128
110
35
125
102
45°
40
120
93
45
114
83
50
107
72
55
99
61
30°
60
91
49
15°
65
82
36 0°
70
74
24
Candela
Distribution
0-180 90-270 150° 120°
0
140
140
Degrees
5
139
141
10
137
141
15
134
142
20
129
141
25
124
140
30
117
139
35
109
137
40
99
132
45
89
125
50
77
117
55
65
108
60
52
97
65
38
87 0°
15°
70
24
75
105°
90°
75°
60°
45°
30°
3 x 36 W
Efficiency 53.3%
NF C 71-121: 0.47 G + 0.06 T
105°
90°
75°
60°
45°
30°
Candela
Distribution
0-180 90-270
0
125
125 165° 135° 120°
5
125
125
Degrees
10
125
124
15
124
122
20
123
119
25
121
114
30
118
108
35
115
101
40
109
92
45
103
82
50
96
72
55
89
60
60
81
48 0°
15°
65
73
36
70
65
24
105°
90°
75°
60°
45°
30°
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
Code•Master™ Incandescent Factory Sealed Luminaires
Explosionproof, Dust-Ignitionproof
For use with threaded metal conduit.
NEC:
Class I, Division 1, Groups C, D
Class II, Division 1 and 2, Groups E, F, G
Class III
NEMA 3R, 4X
CEC: V
Class I, Division 1 and 2, Groups B, C, D. T3B
Class I, Zone 1 and 2, Groups IIB, IIA
Exd IIB + H2, Zone 1
Class II, Division 1 and 2, Groups E, F, G. T3B
Class III
Type 3R, 4X
Applications
• Code•Master Incandescent Explosionproof fixtures are
designed to provide safe operation in the presence of hazardous
gases, vapors, or dusts, defined by the National Electrical Code
as Class I, Groups C and D; Class I, Zone 1, Group IIB; and
Class II, Groups E, F and G.
• For use in hazardous locations such as plants where plastics,
paints, thinners and petrochemicals are manufactured.
• For use in chemical and petrochemical plants, such as
manufacturers of plastics, paints and thinners, in refineries,
and in other areas where ignitable vapors, dust, moisture and
corrosive elements may be present.
• Suitable for outdoor saltwater locations and for other
wet locations.
Features
Standard Materials
• Fixture housing, mounting hoods and guards: copperfree
(4/10 of 1% max.) aluminum
• Globes: prismatic glass
• Reflectors: fiberglass reinforced polyester
Standard Finishes
• Fixture housing, guards and mounting hoods: epoxy power
coat finish, electrostatically applied for complete, uniform
corrosion protection
Options
• Add suffix -Z for Exd IIB + H2, Zone 1 V.
Certifications and Compliances
• UL Standard: UL 1598, UL 1598A, UL 844
• UL Listed: E10444
Lighting
V CSA Certification only.
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
Lighting: Explosionproof — Area — Incandescent
• Fixtures operate safely in high ambient temperatures.
• Patented “wireless” design. Threading of fixture unit
onto mounting hood makes electrical connection. The
only wiring required is attaching two wires to connection
block in mounting hood.
• Connection block is easily wired: (a) loosen two screws; (b)
make wire connections; and (c) re-position connection block.
• Safe, easy servicing without disconnecting any wiring.
“Wireless” fixture unit threads off mounting hood for convenient
servicing or for immediate replacement with a “stand-by” unit.
• Acme double-lead threads speed installation and fixture removal
from mounting hood – only half as many turns are required
as for single-lead threads. The threads do not stick or gall,
eliminating problems often encountered with single-lead threads
during fixture unit removal.
• Strategic location of lamp socket, in combination with interior
prism design of the glass globe, provides optimum light
distribution and control.
• Heat- and impact-resistant globes have smooth
dust-resistant exterior.
• Superior corrosion resistance, with epoxy powder coat finish.
• Porcelain socket with nickel-plated phosphor bronze screw
shell. Assures long trouble-free operation in high ambient areas.
• Choice of mountings: pendant, ceiling, bracket and stanchion.
• Fiberglass-reinforced polyester reflectors, in standard dome
or 30° angle styles, are ideal in installations where luminaire is
subject to exceptionally severe corrosive atmospheres.
• All threaded joints are flame-tight.
• Heat- and impact-resistant globes have smooth
dust-resistant exterior.
• Superior corrosion resistance, with epoxy powder coat finish.
• Optional guards protect globes from damage. Secured to fixture
with three stainless steel screws.
• Medium base lamp socket.
• Maximum voltage 300 Vac 60 Hz.
1269
Code•Master™ Incandescent Factory Sealed Luminaires
Explosionproof, Dust-Ignitionproof
For use with threaded metal conduit.
NEC:
Class I, Division 1, Groups C, D
Class II, Division 1 and 2, Groups E, F, G
Class III
NEMA 3R, 4X
Class III
Type 3R, 4X
CEC: V
Class I, Division 1 and 2, Groups B, C, D. T3B
Class I, Zone 1 and 2, Groups IIB, IIA
Exd IIB + H2, Zone 1
Class II, Division 1 and 2, Groups E, F, G. T3B
Order using catalog numbering guide below or select catalog number from tables on following pages.
Catalog Numbering Guide
CI
P
30
Series:
CI – Code•Master Incandescent
75
Wattage:
30 – 100 W A21
200 W A23
300 W PS25
Options:
G – Guard
Blank – No Guard
Z - Exd IIB + H2, Zone 1 V
Lighting: Explosionproof — Area — Incandescent
Mounting Hood:
P – Pendant
B – Wall Bracket
C – Ceiling
S – Stanchion
Lighting
G
Hub Size:
75 – 3/4”
100 – 1”
150 – 1-1/4” or 1-1/2”
Technical Data Thermal Suitability of Code•Master Incandescent Fixture.
Lamp Type
Lamp Watts
(Max.)
Use Wire Supply
°F/°C
Ambient
Temperature
°F/°C
Incandescent (A21)
100
167/75
104/40
T5
T3C
Incandescent (A23)
200
167/75
104/40
T4
T3C
Incandescent (PS25)
300
167/75
104/40
T3C
T3C
Class I, Division 1,
Groups C & D
Class II, Division 1,
Groups E, F & G
“T” Numbers Represent the Maximum External Temperature for Class I, Division 1 Locations and
Maximum Surface Temperature Under Dust Blanket for Class II, Division 1 Locations.
“T”
Number
T1
350
325
T2
T2A
T2B
T2C
T2D
T3
T3A
T3B
T3
T4
T4A
T5
T6
Temp
Range
(°F)
664842
619662
574617
538572
502536
448500
421446
394419
358392
331356
322329
277320
250275
214248
187212
185
Temp
Range
(°C)
351450
326350
301325
281300
261280
231260
216230
201215
181200
166180
161165
136160
121135
101120
86100
85
NOTE: The maximum operating temperature of the fixture must not exceed the ignition temperature of the gas, vapor or dust to be encountered per the National
Electrical Code and the Canadian Electrical Code..
V CSA Certification only.
1270
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
Code•Master™ Incandescent Factory Sealed Luminaires
Explosionproof, Dust-Ignitionproof
For use with threaded metal conduit.
NEC:
Class I, Division 1, Groups C, D
Class II, Division 1 and 2, Groups E, F, G
Class III
NEMA 3R, 4X
CEC: V
Class I, Division 1 and 2, Groups B, C, D. T3B
Class I, Zone 1 and 2, Groups IIB, IIA
Exd IIB + H2, Zone 1
Class II, Division 1 and 2, Groups E, F, G. T3B
Class III
Type Mounting
Type 3R, 4X
Hub Size (Inches)
Catalog Number ➌
Pendant
CIP3075
3/4
One Hub
Rigid Conduit.
CIP30100 ➋
1
Ceiling
Four Hubs
Three Close-Up Plugs
Rigid Conduit
CIC3075
3/4
CIC30100 ➋
1
Wall Bracket
Four Hubs
Three Close-Up Plugs
Rigid Conduit
CIB3075
3/4
1
CIB30100 ➋
One Hub
1-1/2 ♦
CIS30150
Mounting Hoods
Type Mounting
Hub Size (Inches)
Hood Weight (Lbs.)
Catalog Number
Pendant
3/4
2/.9
CAP75
1
2/.9
CAP100 ➋
Four Hubs
Three Close-Up Plugs
Rigid Conduit
3/4
4/1.8
CAC75
1
4/1.8
CAC100 ➋
Four Hubs
Three Close-Up Plugs
Rigid Conduit
3/4
6/2.7
CALB75
1
6/2.7
CALB100 ➋
1-1/4 or 1-1/2 ➊
2/.9
CAS-150 ➊
One Hub
Rigid Conduit
Ceiling
Lighting: Explosionproof — Area — Incandescent
25° Stanchion
Bracket
One Hub
➊ 1-1/2” Tapped hub furnished with 1-1/2” to 1-1/4” reducer.
➋ 1” Hubs are listed for Group D only.
➌ Catalog numbers shown are supplied with clear lens. Add suffix G for optional Guard.
V CSA Certification only.
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
1271
Lighting
25° Stanchion
Code•Master™ Incandescent Factory Sealed Luminaire Fixture Units and Accessories
Explosionproof, Dust-Ignitionproof
For use with threaded metal conduit.
NEC:
Class I, Division 1, Groups C, D
Class II, Division 1 and 2, Groups E, F, G
Class III
NEMA 3R, 4X
CEC: V
Class I, Division 1 and 2, Groups B, C, D. T3B
Class I, Zone 1 and 2, Groups IIB, IIA
Exd IIB + H2, Zone 1
Class II, Division 1 and 2, Groups E, F, G. T3B
Class III
Description
Weight lbs/kg
Type 3R, 4X
Catalog Number
Fixture Unit Only
Not including mounting
hood
11/5
CJNC30I
Optional White Polyester Reflector
Standard Dome
2.5/1.1
KR2-ST
Angled Reflector
2.5/1.1
KR2-AN
0.5/.2
CJGU-15
7.5/3.4
CJEXRN
0.5/.2
VPT-7
Optional White Polyester Reflector
Optional Three Way Exit Sign
Replacement Connection Block
Lighting
Lighting: Explosionproof — Area — Incandescent
Optional Aluminum Guard
1272
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
Code•Master™ Incandescent Factory Sealed Luminaire Family Tree and Dimensions
Explosionproof, Dust-Ignitionproof
For use with threaded metal conduit.
NEC:
Class I, Division 1, Groups C, D
Class II, Division 1 and 2, Groups E, F, G
Class III
NEMA 3R, 4X
Type 3R, 4X
CEC: V
Class I, Division 1 and 2, Groups B, C, D. T3B
Class I, Zone 1 and 2, Groups IIB, IIA
Exd IIB + H2, Zone 1
Class II, Division 1 and 2, Groups E, F, G. T3B
Class III
Ceiling
Four Hubs
Three Close-Up Plugs
3/4” NPT
CAC75
Pendant
One Hub
3/4” NPT
CAP75
Bracket
Four Hubs
Three Close-Up Plugs
3/4” NPT
CALB75
25° Stanchion
One Hub
1-1/4 or 1-1/2” NPT
CAS150
Code•Master
Incandescent
Fixture Unit
CJNC30I
Standard Dome
KR2-ST
Angle Reflector
KR2-AN
Optional Three Way
Exit Sign
CJEXRN
Dimensions in Inches/Millimeters
Hub for .75"
NPT Conduit
Pendant
13.88"/
352.6 mm
4.50"/
114.3 mm
Wall Bracket
3.75"/
95.3 mm
4.92"/
125.0 mm
12.38"/
314.5 mm
Hub For
0.41"/
10.4 mm Dia.
13.15"/
334.0 mm
3/4” NPT
2.46"/
62.5 mm
2.28"/
57.9 mm
2” Wiring access
13.53"/
343.7 mm
3.92"/
99.6 mm
13.75"/
349.3 mm
cover both sides.
4.25"/
108.0 mm
4.92"/
125.0 mm Sq.
1.23"/
31.2 mm
3.46"/
87.9 mm
1.79"/
45.5 mm
11.5"/
292.1 mm
7.80"/
198.1 mm
13.75"/
349.3 mm
Ceiling
25° Stanchion
5.95"/
151.3 mm
7.80"/
198.1 mm
4.00"/
101.6 mm
4.00"/
101.6 mm
4.00"/
101.6 mm
25˚
Hub for .75" NPT
Conduit Four Sides
Lighting
13.38"/
339.9 mm
11.93"/
303.0 mm
13.00"/
330.2 mm
12.87"/
326.9 mm
4.50"/
114.3 mm
Dia.
5.92"/
150.4 mm
7.80"/
198.1 mm
11.43"/
290.3 mm
12.48"/
317.0 mm
V CSA Certification only.
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
Lighting: Explosionproof — Area — Incandescent
Optional Aluminum
Guard
CJGU-15
1273
A-51® Incandescent Factory Sealed Luminaires
Explosionproof
Suitable for use in Wet Locations. UNILETS for use with Threaded Metal Conduit.
For Group A and B
Class I, Division 1 and 2, Groups A , B, C, D
Class II, Division 1 and 2, Groups E, F, G
Class III
For Group C and D
Class I, Division 1 and 2, Groups C, D
Class II, Division 1 and 2, Groups E, F, G*
Class III
Applications
Group A and B
• A-51 Series Incandescent Class I, Groups A, B, C and D; and
Class II, Groups E, F and G applications (see listings and area
suitability chart).
• Ideal for use in chemical and petrochemical plants, and in other
heavy process areas where ignitable vapors, dust, moisture and
corrosive atmospheres may be present.
• Suitable for use in wet locations.
• Wide range of wattages – 60 W through 500 W
incandescent lamps.
• Choice of units with or without guard, as well as choice of
porcelain, polyester or aluminum reflectors.
• Choice of mountings: pendant, ceiling, 25° stanchion, long
bracket and 15° short bracket.
• Porcelain reflectors for standard applications and fiberglass
reinforced polyester reflectors for installations where fixture is
subject to exceptionally severe corrosive atmospheres. High
bay reflector for installations where mounting height from work
plane ranges from 20 to 30 feet/508" to 762 mm.
• Class I, Groups A and B fixtures have special UL-approved
sintered metal flame arrester.
Polyester Reflector
Porcelain Reflector
Group C and D
Lighting
Lighting: Explosionproof — Area — Incandescent
Features
• All A-51 fixtures are factory-sealed; no external sealing
fittings required.
• New high temperature phenolic connection block in mounting
hood has rugged leaf spring contacts – loosen two screws,
rotate and remove for quick wiring.
• Safe, easy servicing or relamping without disconnecting any
wiring. “Wireless” fixture unit easily threads off mounting hood
for convenient servicing or for immediate exchange with “standby” unit.
• All joints are flame-tight.
• Specially formulated two-coat baked epoxy enamel provides
superior protective finish to resist corrosion. Applied to all
mounting hoods, fixture units and guards.
• New high temperature glass-reinforced phenolic socket
block in fixture unit has collector ring and pin that automatically
make electrical contact as fixture unit is threaded onto
mounting hood.
• Globes in A-51 fixtures are explosionproof and heat- and
impact-resistant glass. Prismatic configuration on globe
interior provides light control while allowing smooth exterior
surface for cleaning.
• A-51 fixture units have standardized threads to fit all A-51
and mounting hoods.
• All fixtures have aluminum inner reflector for increased lumen
efficiency.
• A-51 fixture guards to protect globe are of rugged copperfree
aluminum construction and double epoxy coated. Easily mount
to globe ring with 3 screws.
Polyester Reflector
Porcelain Reflector
Standard Finishes
• Fixtures, guards and mounting hoods: two-coat epoxy-clad
finish. Epoxy powder coat finish, electrostatically applied for
complete, uniform surface protection.
• Steel reflectors: white porcelain enamel.
• Polyester and aluminum reflectors: natural finish.
Certifications and Compliances
•
•
•
•
UL Standard: UL 1598, UL 844
UL Listed: E10444
CSA Standard: C22.2 No. 250, C22.2 No. 137
CSA Certified: 025428
Standard Materials
• Fixtures and guards: copperfree (4/10 of 1% max.) aluminum.
• Pendant mounting hoods: copperfree (4/10 of 1% max.)
aluminum.
• Ceiling and bracket mounting hoods: malleable iron with
aluminum adapters.
• Reflectors: porcelain-enameled steel, aluminum or fiberglass
reinforced polyester.
1274
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
A-51® Incandescent Factory Sealed Luminaires
Explosionproof
Suitable for use in Wet Locations. UNILETS for use with Threaded Metal Conduit.
Class I, Division 1 and 2, Groups A, B, C, D.
Class II, Division 1 and 2, Groups E, F, G
Class III
Illustrated Features
Weights
Fixture Units
Catalog Number
Wt. lbs/kgs
AAU-1N
7.6/3.4
AAU-15N
7.6/3.4
AAU-2NS
10.7/4.9
AAU-5NS
20.3/9.2
AAUA-15
15.0/6.8
AAUA-2
18.0/8.2
Mounting Hoods
Type
Wt. lbs/kg
Pendant
1.3/.6
Ceiling
4.8/2.2
Stanchion
1.6/.7
Long Bracket
8.9/4.0
Short Bracket
4.8/2.2
Lighting: Explosionproof — Area — Incandescent
Guards
Catalog Number
Wt. lbs/kgs
AAGU-1
0.4/.2
AAGU-2
0.8/.4
AAGU-5
1.9/.9
AAGUA-15
0.5/.2
Standard Reflectors
Catalog Number
Wt. lbs/kgs
AARP-2ST
2.8/1.3
AARW-15ST
2.1/1.0
AARW-2ST
2.9/1.3
AARW-5ST
4.3/2.0
AARW-15ST
2.1/1.0
30˚° Angle Reflectors
Wt. lbs/kgs
AARP-2AN
3.3/1.5
AARW-15AN
2.1/1.0
AARW-2AN
2.4/1.1
AARW-5AN
7.0/3.2
AARW-15AN
2.1/1.0
Lighting
Catalog Number
High Bay Reflectors
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
Catalog Number
Wt. lbs/kgs
AARE-2HB
2.9/1.3
AARE-5HB
3.9/1.8
1275
A-51® Incandescent Factory Sealed Luminaire Classified Area Suitability
Explosionproof
Suitable for use in Wet Locations. UNILETS for use with Threaded Metal Conduit.
Class I, Division 1 and 2, Groups A, B, C, D.
Class II, Division 1 and 2, Groups E, F, G
Class III
Fixture
Unit
Lamp
Watts
Without
Reflectors
Standard
Dome
30°˚
Angle
High
Bay
Supply Wire
°F/°C
Class I Division 1 and Division 2 Groups C and D
AAU1N
AAU15N
AAU2NS
100 W A19
T5
T5
T5
—
257/125
100 W A21
T5
T5
T5
—
257/125
150 W A23
T3C
T3C
T3C
—
257/125
200 W A25
T3C
T3C
T3C
—
257/125
200 W PS25
T3C
T3C
T3C
—
257/125
300 W PS25
T3C
T3A
T3A (D)
—
257/125
200 W PS25
T3C
T3C
T3C
—
230/110
200 W PS30
T3C
T3C
T3C
—
230/110
300 W PS25
T3C
T3C
T3C
—
230/110
300 W PS30
T3C
T3C
T3C
—
230/110
Class I Division 1 and Division 2 Groups A †, B, C and D
Lighting: Explosionproof — Area — Incandescent
AAUA15
AAUA2
150 W A23
T3C
T3C
T3C
—
230/110
150 W A25
T3C
T3C
T3C
—
230/110
200 W A25
T3C
T3C
T3C
—
230/110
200 W PS25
T3C
T3C
T3C
—
230/110
200 W PS25
T3C
T3C
T3C
—
230/110
200 W PS30
T3C
T3C
T3C
—
230/110
300 W PS25
T3C
T3C
T3C
—
230/110
300 W PS30
T3C
T3C
T3C
—
230/110
T3C
T3C
—
257/125
Class II Division 1 and Division 2 Groups E, F and G
AAU1N
100 W A19
100 W A21
T3C
T3C
T3C
—
257/125
AAU15N
150 W A23
T3C
T3C
T3C
—
257/125
200 W A25
T3C
T3C
T3C
—
257/125
200 W PS25
T3
T3
T3
—
257/125
300 W PS25
T3
—
—
—
257/125
Lighting
AAU2NS
T3C
200 W PS25
T3C
T3C
T3C
—
230/110
200 W PS30
T3C
T3C
T3C
—
230/110
300 W PS25
T3C
T3C
T3A (EF)
—
230/110
300 W PS30
T3C
T3C
T3A (EF)
—
230/110
NOTE: Ambient suitability of these incandescent fixtures: 104°F/40 °C
† For Group A, use Pendant Mount only.
1276
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
A-51® Incandescent Factory Sealed Luminaires
For Group C and D Locations. Explosionproof
Suitable for use in Wet Locations. UNILETS for use with Threaded Metal Conduit.
Class I, Division 1 and 2, Groups C, D
Class II, Division 1 and 2, Groups E, F, G
Class III
Hub Size
(Inches)
Catalog
Number ➋
60-100 W (AAU-1N)
A-21
1/2
AP1050
3/4
AP1075
1
AP10100
150-300 W (AAU-15N)
A-23 PS-25
1/2
AP1550
3/4
AP1575
Type
Pendant — One Hub, Rigid or Flexible Mounting
1
AP15100
1/2
AP2050
3/4
AP2075
1
AP20100
1/2
AC1050
3/4
AC1075
1
AC10100
1/2
AC1550
3/4
AC1575
1
AC15100
1/2
AC2050
3/4
AC2075
1
AC20100
60-100 W (AAU-1N)
A-21
1-1/2 ➋
AN10150
150-300 W (AAU-15N)
A-23 PS-25
1-1/2 ➋
AN15150
200-300 W (AAU-2NS)
PS-30
1-1/2 ➋
AN20150
200-300 W (AAU-2NS)
PS-30
Ceiling — Four Hubs, Three Close-up Plugs
150-300 W (AAU-15N)
A-23 PS-25
200-300 W (AAU-2NS)
PS-30
Lighting: Explosionproof — Area — Incandescent
60-100 W (AAU-1N)
A-21
25° Stanchion — One Hub — Not UL Listed
Lighting
➊ See A-51® Incandescent Factory Sealed Luminaire Classified Area Suitability page for suitability of specific fixtures.
➋ 1-1/2” tapped hub furnished with a 1-1/2” to 1-1/4” reducer.
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
1277
A-51® Incandescent Factory Sealed Luminaires
For Group C and D Locations. Explosionproof
Suitable for use in Wet Locations. UNILETS for use with Threaded Metal Conduit.
Class I, Division 1 and 2, Groups C, D
Class II, Division 1 and 2, Groups E, F, G
Class III
Hub Size
(Inches)
Type
Catalog
Number ➋
Long Bracket — Four Hubs, Three Close-up Plugs
60-100 W (AAU-1N)
A-21
1/2
ALB1050
3/4
ALB1075
1
ALB10100
150-300 W (AAU-15N)
A-23 PS-25
1/2
ALB1550
3/4
ALB1575
1
ALB15100
1/2
ALB2050
3/4
ALB2075
1
ALB20100
60-100 W (AAU-1N)
A-21
1/2
ASB1050
3/4
ASB1075
150-300 W (AAU-15N)
A-23 PS-25
1/2
ASB1550
3/4
ASB1575
200-300 W (AAU-2NS)
PS-30
1/2
ASB2050
3/4
ASB2075
200-300 W (AAU-2NS)
PS-30
Lighting
Lighting: Explosionproof — Area — Incandescent
15° Short Bracket — Two Hubs, One Close-up Plug
Three-Way Exit Sign
Epoxy enameled steel – 6”/152.4 mm-high red lettering 60-200 W
(Mounts to AAU-1N or AAU-15N fixture units in place of guard)
CJEXRN
Epoxy enameled steel – 6”/152.4 mm-high red lettering 60-200 W
(Mounts to AAU-1N or AAU-15N fixture units in place of guard)
(See page G2-24 for dimensions)
AEXR-15R
Single-Sided Exit Sign
Guard — Add suffix to fixture catalog number
-G
Guard
➊ See A-51® Incandescent Factory Sealed Luminaire Classified Area Suitability page for suitability of specific fixtures.
1278
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
A-51® Incandescent Factory Sealed Luminaire Accessories
For Group C and D Locations. Explosionproof
Suitable for use in Wet Locations. UNILETS for use with Threaded Metal Conduit.
Class I, Division 1 and 2, Groups C, D
Class II, Division 1 and 2, Groups E, F, G
Class III
Mounting Hoods
Type
Hub Size (Inches)
Catalog Number
Pendant — One Hub, Rigid or Flexible Mounting
1/2
AAP-50
3/4
AAP-75
1
AAP-100
1/2
AAC-50
3/4
AAC-75
1
AAC-100
Ceiling — Four Hubs, Three Close-up Plugs
25° Stanchion — Not UL Listed — One Hub
1-1/2
AAN-150 ➊
Long Bracket — Four Hubs, Three Close-up Plugs
AALB-50
3/4
AALB-75
1
AALB-100
1/2
AASB-50
3/4
AASB-75
15˚ Short Bracket — Two Hubs, One Close-up Plug
Type
Catalog Number
Fixture Units
60-100 W A-21
AAU-1N
150-300 W A-23 & PS-25
AAU-15N
200-300 W PS-30
AAU-2NS
60-100 W (AAU-1N)
AAGL-1PR
150-300 W (AAU-15N)
AAGL-1PR
200-300 W (AAU-2NS)
AAGL-2PR
60-100 W (AAU-1N)
AAGU-1
150-300 W (AAU-15N)
AAGU-1
200-300 W (AAU-2NS)
AAGU-2
300-500 W (AAU-5NS)
AAGU-5
Lighting: Explosionproof — Area — Incandescent
1/2
Prismatic Glass Globes
➊ 1-1/2” tapped hub furnished with a 1-1/2” to 1-1/4” reducer.
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
1279
Lighting
Aluminum Guards
A-51® Incandescent Factory Sealed Luminaire Accessories
For Group C and D Locations. Explosionproof
Suitable for use in Wet Locations. UNILETS for use with Threaded Metal Conduit.
Type
Standard Dome
Fixture Size
Catalog Number
(Not for use with short brackets)
Porcelain
Polyester
60-100 W (AAU-1N)
150-300 W (AAU-15N)
200-300 W (AAU-2NS)
300-500 W (AAU-5NS)
Porcelain
AARW-15ST
AARW-15ST
AARW-2ST
AARW-5ST
Polyester
—
—
AARP-2ST
—
60-100 W (AAU-1N)
150-300 W (AAU-15N)
200-300 W (AAU-2NS)
AARW-15AN
AARW-15AN
AARW-2AN
—
—
AARP-2AN
30˚ Angle
Porcelain
Polyester
Colored Glass Globes
Lighting: Explosionproof — Area — Incandescent
Amber
AAGL-1A
AAGL-1A
AAGL-2A
60-100 W (AAU-1N)
150-300 W (AAU-15N)
200-300 W (AAU-2NS)
Green
AAGL-1G
AAGL-1G
AAGL-2G
60-100 W (AAU-1N)
150-300 W (AAU-15N)
200-300 W (AAU-2NS)
Red
60-100 W (AAU-1N)
150-300 W (AAU-15N)
200-300 W (AAU-2NS)
AAGL-1R
AAGL-1R
AAGL-2R
60-100 W (AAU-1N) — Medium Base
150-300 W (AAU-15N) — Medium Base
200-300 W (AAU-2NS) — Medium Base
300-500 W (AAU-5NS) — Mogul Base
AASP-11
AASP-22
AASP-22
AASP-44
Replacement Socket
Connection Block
Fits A-51 Mounting Hoods
VPT-7
Lighting
60-500 W
Globe Gaskets — Fiber and Aluminum
Requires one of each
60-300 W (AAU-1N and AAU-15N)
200-300 W (AAU-2NS)
300-500 W (AAU-NS)
1280
Fiber
AASP-15V
AASP-2V
AASP-5V
Aluminum
AASP-15A
AASP-2A
AASP-5A
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
A-51® Incandescent Factory Sealed Luminaire Dimensions
For Group C and D Locations. Explosionproof
Suitable for use in Wet Locations. UNILETS for use with Threaded Metal Conduit.
3.38"/
85.9 mm
5.38"/
116.7 mm
4.69"/
119.1 mm
Stanchion
.38"/
2.69"/
9.7 mm 68.3
mm
2.63"/
66.8 mm
.38"/
9.7 mm
5.75"/
146.1 mm
Size (Watts)
4.75"/
120.7 mm
1.31"/
33.3 mm
Pendant ➊
Ceiling
Long Bracket
Short Bracket
C
A
B
C
A
B
C
7.06/ 13.75/ 13.13/ 12.38/ 13.56/ 12.94/ 9.13/
179.3 349.3 333.5 314.5 344.4 328.7 231.9
150-300
11.47/ 10.85/ 11.50/ 12.25/ 11.63/ 7.06/ 13.75/ 13.13/
291.3 275.6 292.1 311.2 295.4 179.3 349.3 333.5
7.06/ 13.75/ 13.13/ 12.38/ 13.56/ 12.94/ 9.13/
179.3 349.3 333.5 314.5 344.4 328.7 231.9
200-300
13.07/ 12.38/ 12.71/ 13.94/ 13.25/ 8.81/ 15.44/ 14.75/
332.0 314.5 322.8 354.1 336.6 223.8 392.2 374.7
8.81/ 15.50/ 14.75/ 13.25/ 15.19/ 14.50/ 10.13/
223.8 392.2 374.7 336.6 385.8 363.8 257.3
300-500
15.09/ 14.34/ 14.64/ 16.00/ 15.25/ 12.13/ 17.50/ 17.75/ 12.13/ 17.50/ 16.75/ 14.88/ 17.25/ 16.50/ 11.94/
383.3 364.2 371.8 406.4 387.4 308.1 444.5 450.9 308.1 444.5 425.9 378.0 438.2 419.1 303.3
60-100
A➋
B➋
A
B
A
60-100
Size (Watts)
12.00/304.8
4.50/114.3
10.00/254.0
7.63/193.8
-
B
150-200
14.00/355.6
4.38/111.3
10.00/254.0
7.63/193.8
-
-
200-300
16.00/406.4
5.19/131.8
12.00/304.8
7.88/200.2
12.00/304.8
6.06/153.9
300-500
20.00/508.0
6.84/173.7
18.00/457.2
13.13/333.5
18.00/457.2
9.13/231.9
-
Lighting: Explosionproof — Area — Incandescent
A
B
C
A
B
C
A
B
11.47/ 10.85/ 11.50/ 12.25/ 11.63/ 7.06/ 13.75/ 13.13/
291.3 275.6 292.1 311.2 295.4 179.3 349.3 333.5
Lighting
➊ For dimensions of fixture unit only, subtract pendant hood dimension 1.31”/3.3 cm from dimensions A and B as listed.
➋ Dimensions illustrated are for porcelain steel (dome and angle) and etched aluminum (high bay).
Overall dimensions for fiberglass reinforced polyester reflectors are: standard dome – 16-1/2”/419.1 mm dia., 6” high; 30° Angle – 14-3/8”/374.7 mm dia.,
10”/254 mm high.
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
1281
A-51® Incandescent Factory Sealed Luminaire Photometric Data
For Group C and D Locations. Explosionproof
Suitable for use in Wet Locations. UNILETS for use with Threaded Metal Conduit.
Photometric data shown here is based on a 200-
watt type PS-30 lamp and is representative of
the performance for all A-51 incandescent fixtures
using 60-watt to 500-watt lamps. For candlepower
values of fixtures with other lamps, use the following
multipliers:
60 W A-19 – 0.23;
150 W A-21 – 0.75;
200 W A-25 – 1.02;
300 W PS-25 – 1.70;
300 W PS-35 – 1.55;
500 W PS-40 – 2.69.
A-51 Incandescent
Fixture without Reflector
Spacing to Mtg. Ht.
Ratio 1.25:1
Guard .877
100 W A-19 – 0.47;
200 W A-23 – 1.07;
200 W PS-25 – 1.03:
300 W PS-30 – 1.63;
500 W PS-35 – 2.95;
To determine candlepower values of fixtures with a
guard, multiply by value shown with each curve.
Effective Floor Cavity Reflectance (Rfc) is 20%
% Ceiling Rcc
% Walls Rw
80
50
30
70
10
50
30
50
10
50
30
30
10
50
30
10
10
50
30
0
10
0
1 .735 .690 .651 .695 .655 .618 .622 .590 .561 .554 .530 .506 .493 .473 .454 .422
ROOM CAVITY RATIOS
2 .621 .558 .503 .588 .530 .481 .525 .478 .437 .467 .430 .396 .413 .384 .357 .327
3 .540 .468 .411 .512 .446 .394 .457 .404 .359 .406 .363 .327 .360 .325 .294 .267
4 .474 .400 .342 .450 .381 .328 .402 .346 .301 .359 .312 .274 .318 .280 .248 .223
5 .415 .341 .284 .394 .325 .272 .354 .295 .251 .316 .266 .229 .280 .240 .207 .184
6 .372 .297 .245 .352 .284 .233 .316 .258 .215 .283 .234 .197 .252 .210 .178 .157
7 .334 .262 .213 .317 .249 .203 .285 .227 .187 .255 .207 .170 .228 .187 .155 .136
8 .300 .231 .182 .285 .221 .175 .256 .202 .162 .231 .183 .148 .206 .165 .135 .117
9 .271 .204 .157 .258 .195 .152 .233 .178 .140 .209 .162 .128 .187 .146 .117 .100
10 .246 .181 .139 .234 .175 .135 .212 .160 .124 .191 .145 .113 .172 .132 .102 .087
Lighting: Explosionproof — Area — Incandescent
A-51 Incandescent Fixture with
Standard Dome Reflector
Spacing to Mtg. Ht.
Ratio 1.25:1
Guard .890
Effective Floor Cavity Reflectance (Rfc) is 20%
% Ceiling Rcc
% Walls Rw
80
50
30
70
10
50
30
50
10
50
30
30
10
50
30
10
10
50
30
0
10
0
1 .757 .727 .700 .740 .713 .689 .709 .686 .667 .681 .663 .646 .656 .641 .627 .612
ROOM CAVITY RATIOS
2 .660 .613 .572 .647 .603 .567 .621 .585 .552 .598 .568 .540 .577 .551 .528 .512
3 .580 .524 .478 .570 .516 .475 .549 .504 .466 .529 .490 .458 .511 .478 .449 .434
4 .514 .452 .403 .504 .446 .400 .486 .436 .395 .469 .425 .390 .454 .415 .384 .368
5 .451 .385 .336 .442 .380 .334 .427 .372 .332 .413 .364 .327 .399 .357 .323 .308
6 .402 .336 .291 .394 .333 .286 .381 .326 .285 .369 .319 .282 .358 .313 .279 .264
7 .361 .296 .254 .355 .293 .250 .343 .286 .247 .332 .282 .245 .323 .278 .243 .229
8 .323 .261 .216 .318 .258 .216 .308 .254 .215 .299 .249 .213 .290 .245 .211 .197
9 .291 .230 .187 .287 .227 .187 .278 .223 .186 .269 .219 .184 .262 .216 .182 .169
Lighting
10 .264 .204 .166 .259 .204 .166 .253 .200 .164 .245 .197 .162 .240 .194 .161 .149
1282
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
A-51® Incandescent Factory Sealed Luminaire Photometric Data
For Group C and D Locations. Explosionproof
Suitable for use in Wet Locations. UNILETS for use with Threaded Metal Conduit.
Photometric data shown here is based on a 200watt type PS-30 lamp and is representative of the
performance for all A-51 incandescent fixtures
using 60-watt to 500-watt lamps. For candlepower
values of fixtures with other lamps, use the following
multipliers:
60 W A-19 – 0.23;
150 W A-21 – 0.75;
200 W A-25 – 1.02;
300 W PS-25 – 1.70;
300 W PS-35 – 1.55;
500 W PS-40 – 2.69.
100 W A-19 – 0.47;
200 W A-23 – 1.07;
200 W PS-25 – 1.03:
300 W PS-30 – 1.63;
500 W PS-35 – 2.95;
To determine candlepower values of fixtures with a
guard, multiply by value shown with each curve.
Effective Floor Cavity Reflectance (Rfc) is 20%
% Ceiling Rcc
A-51 Incandescent Fixture
with High Bay Reflector
% Walls Rw
80
50
30
70
10
50
30
50
10
50
30
30
10
50
30
10
10
50
30
0
10
0
1 .686 .644 .645 .671 .651 .634 .644 .628 .614 .620 .607 .595 .598 .588 .577 .566
Spacing to Mtg.
Ht. Ratio 1.40:1
Guard .865
12.00"/
304.8 mm
ROOM CAVITY RATIOS
2 .614 .580 .549 .603 .571 .545 .581 .555 .531 .562 .540 .520 .544 .525 .508 .496
3 .550 .508 .473 .542 .501 .470 .524 .490 .461 .507 .478 .454 .492 .467 .446 .434
4 .493 .445 .408 .486 .441 .404 .470 .431 .400 .456 .422 .395 .443 .413 .389 .377
5 .439 .387 .349 .432 .383 .347 .420 .376 .344 .407 .369 .340 .396 .383 .336 .324
6 .393 .340 .304 .387 .338 .300 .376 .331 .298 .366 .326 .296 .356 .320 .293 .281
7 .352 .299 .264 .347 .296 .261 .337 .290 .258 .327 .287 .256 .320 .283 .254 .242
8 .313 .261 .224 .309 .259 .223 .300 .255 .222 .293 .251 .220 .285 .247 .219 .207
9 .280 .228 .191 .276 .225 .191 .268 .222 .190 .261 .219 .189 .254 .216 .187 .176
10 .252 .201 .168 .248 .201 .168 .242 .197 .167 .236 .195 .165 .231 .192 .164 .153
Lighting: Explosionproof — Area — Incandescent
A-51 Incandescent Fixture
with 30°˚ Reflector
11.16"/
283.5 mm
B—
Back
S—Side
F—Front
G—Front W.Guard
Lighting
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
1283
A-51® Incandescent Factory Sealed Luminaires
For Group A and B Locations. Explosionproof
Suitable for use in Wet Locations. UNILETS for use with Threaded Metal Conduit.
Class I, Division 1 and 2, Groups A, B, C, D
Class II, Division 1 and 2, Groups E, F, G
Class III
Hub Size
(Inches)
Catalog
Number ➊➋
Pendant — One Hub, Rigid or Flexible Mounting
60-200 W (AAUA-15)
1/2
AAPA1550
PS-25
3/4
AAPA1575
200-300 W (AAUA-2)
1/2
AAPA2050
PS-30
3/4
AAPA2075
60-200 W (AAUA-15)
1/2
AACA1550
PS-25
3/4
AACA1575
200-300 W (AAUA-2)
1/2
AACA2050
PS-30
3/4
AACA2075
60-200 W (AAUA-15)
1/2
AASBA1550
PS-25
3/4
AASBA1575
200-300 W (AAUA-2)
1/2
AASBA2050
PS-30
3/4
AASBA2075
Porcelain
Polyester
Lighting: Explosionproof — Area — Incandescent
Ceiling — Four Hubs, Three Close-up Plugs
15˚ Short Bracket — Two Hubs, One Close-up Plug
Reflectors
Porcelain
Polyester
Standard Dome
60-200 W (AAUA-15)
AARW-15ST
200-300 W (AAUA-2)
AARW-2ST
60-200 W (AAUA-15)
AARW-15AN
200-300 W (AAUA-2)
AARW-2AN
AARP-2ST
30˚ Angle
Lighting
AARP-2AN
➊ See A-51® Incandescent Factory Sealed Luminaire Classified Area Suitability page for suitability of specific fixtures.
➋ Add suffix -G to catalog number for optional guard.
Shaded area indicates pendant mount is suitable for Class I, Group A in addition to other applicable area suitabilities.
1284
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
A-51® Incandescent Factory Sealed Luminaires
For Group A and B Locations. Explosionproof
Suitable for use in Wet Locations. UNILETS for use with Threaded Metal Conduit.
Class I, Division 1 and 2, Groups A, B, C, D
Class II, Division 1 and 2, Groups E, F, G
Class III
Mounting Hoods
Type
Hub Size (Inches)
Catalog Number
One Hub,
Rigid or Flexible Mounting
1/2
AAP-50 ➊
3/4
AAP-75 ➊
Four Hubs,
Three Close-up Plugs
1/2
AAC-50
3/4
AAC-75
Two Hubs,
One Close-up Plug
1/2
AASB-50
3/4
AASB-75
Pendant
Ceiling
15˚ Short Bracket
Description
Catalog Number
60-200 W
PS-25
AAUA-15
200-300 W
PS-30
AAUA-2
60-200 W (AAUA-15)
AAGLA-15
200-300 W (AAUA-2)
AAGLA-2
60-200 W (AAUA-15)
AAGUA-15
200-300 W (AAUA-2)
AAGU-2
60-200 W (AAUA-15)
AASPA-15
200-300 W (AAUA-2)
AASPA-22
Globe and Ring Assembly
Aluminum Guards
Lighting: Explosionproof — Area — Incandescent
Fixture Units
Medium Base Lamp Socket
Fits all A-51 and AA-51 mounting hoods
60-300 W
VPT-7
➊ Group A pendant mount only.
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
1285
Lighting
Connection Block
A-51® Incandescent Factory Sealed Luminaire Dimensions
For Group A and B Locations. Explosionproof
Suitable for use in Wet Locations. UNILETS for use with Threaded Metal Conduit.
Dimensions in In/mm
4.75"/
120.7 mm
3.38"/
85.9 mm
5.38"/
116.7 mm
.38"/
9.7 mm
2.63"/
66.8 mm
4.69"/
119.1 mm
.38"/
9.7 mm
Size
(Watts)
Pendant
A
B
Ceiling
C
A
B
Short Bracket
C
A
B
C
60-200
13.69/347.7 13.13/333.5
7.06/179.3 16.50/419.1 15.94/404.9
7.06/179.3 15.00/381.0 14.44/366.8
9.50/241.3
200-300
14.75/374.7 13.69/347.7
8.81/223.8 17.56/446.0 16.50/419.1
8.81/223.8 16.00/406.4 15.44/392.2 10.38/263.7
Lighting
Lighting: Explosionproof — Area — Incandescent
1.31"/
33.3 mm
1286
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
A-51® Incandescent Factory Sealed Luminaire Photometric Data
For Group A and B Locations. Explosionproof
Suitable for use in Wet Locations. UNILETS for use with Threaded Metal Conduit.
Photometric data shown here is based on a 200-watt
type PS-25 lamp, and is representative of the performance for A-51 incandescent fixtures (Groups A and
B). For candlepower values of fixtures with other lamps,
use the following multipliers: 150 W (PS-25) – 0.70; and
300 W (PS-25) – 1.6. To determine candlepower values
of fixtures with a guard, multiply by value shown with
each curve.
Effective Floor Cavity Reflectance (Rfc) is 20% (No Reflector)
% Ceiling Rcc
% Walls Rw
80
50
30
70
10
50
30
50
10
50
30
30
10
50
30
10
10
50
30
0
10
0
1 .711 .669 .630 .669 .631 .595 .590 .560 .533 .518 .495 .473 .452 .434 .417 .383
ROOM CAVITY RATIOS
2 .602 .541 .488 .567 .511 .465 .499 .455 .416 .437 .402 .371 .380 .352 .327 .296
7.13"/
181.1 mm
3 .519 .449 .393 .488 .424 .374 .430 .379 .336 .375 .335 .300 .325 .292 .264 .236
4 .456 .384 .328 .430 .364 .312 .379 .325 .282 .332 .288 .252 .288 .252 .223 .197
5 .400 .328 .274 .378 .311 .260 .334 .278 .236 .293 .247 .211 .254 .217 .187 .164
6 .357 .285 .234 .336 .270 .221 .297 .242 .200 .261 .215 .180 .227 .188 .159 .138
7 .318 .248 .200 .300 .234 .190 .265 .209 .171 .233 .187 .153 .204 .165 .135 .116
8 .287 .219 .172 .270 .208 .164 .240 .187 .149 .212 .167 .134 .104 .147 .119 .101
9 .260 .194 .150 .246 .185 .143 .218 .166 .130 .192 .148 .117 .168 .131 .103 .087
10 .236 .173 .132 .222 .166 .126 .199 .149 .114 .175 .133 .102 .154 .117 .090 .075
Effective Floor Cavity Reflectance (Rfc) is 20% (No Reflector)
% Ceiling Rcc
50
30
70
10
50
30
50
10
50
30
30
10
50
30
10
10
50
30
0
10
0
1 .797 .763 .733 .779 .748 .721 .745 .720 .697 .715 .695 .676 .689 .671 .655 .640
14.00"/
355.6 mm
ROOM CAVITY RATIOS
2 .687 .633 .586 .673 .622 .581 .645 .603 .566 .620 .585 .553 .597 .567 .541 .524
3 .594 .530 .478 .583 .522 .474 .560 .508 .464 .538 .494 .457 .519 .481 .448 .431
4 .527 .458 .404 .517 .452 .400 .497 .440 .395 .479 .430 .390 .462 .419 .384 .366
5 .466 .393 .340 .456 .388 .337 .440 .379 .335 .424 .371 .330 .410 .364 .326 .310
6 .414 .342 .292 .406 .339 .288 .391 .331 .286 .378 .324 .283 .367 .317 .280 .264
7 .369 .298 .252 .362 .294 .248 .350 .288 .245 .337 .284 .242 .328 .279 .240 .225
8 .333 .265 .217 .327 .262 .216 .316 .257 .215 .307 .252 .213 .297 .248 .211 .196
9 .302 .235 .189 .297 .232 .189 .287 .229 .188 .278 .224 .186 .270 .221 .185 .170
10 .273 .209 .167 .268 .209 .167 .261 .204 .166 .253 .201 .163 .247 .198 .162 .149
Lighting: Explosionproof — Area — Incandescent
% Walls Rw
80
Lighting
11.16"/
283.5 mm
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
1287
EDT Incandescent Luminaires
Dust-Ignitionproof
Suitable for use in Wet Locations.
Class II, Division 1 and 2, Groups E, F, G
Class III
Description
Watts
Hub Size
(Inches)
60-200 W
1/2
Catalog
Number
Pendant Lighting Fixture ➊
9.00"/
228.6 mm
One tapped opening for rigid or flexible mounting,
with heat-resistant clear globe
EDTP2050
5.25"/
133.4 mm
Heat-Resistant Clear Glass Globe
4.28"/
108.7 mm
7.00"/
177.8 mm
60-200 W
VSGL-2HR
60-200 W
DPGU-2
60-200 W
VPLR-123
5.25"/
133.4 mm
4.28"/
108.7 mm
7.00"/
177.8 mm
5.25"/
133.4 mm
Replacement Porcelain Shock-Absorbing Socket — Medium Base
Lighting
Lighting: Explosionproof — Area — Incandescent
Globe Guard
➊ T3C maximum operating temperature. Supply wire 302 °F/150 °C. Maximum ambient temperature 77 °F/25 °C. Vertical mount only (globe down).
1288
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
Code•Master 2™ HID Factory Sealed Floodlights
Marine (Outside Type). Explosionproof
Integrally Ballasted. 150 W, 250 W, 400 W HPS; 150 W, 175 W, 250 W, 320 W, 350 W, 400 W PSMH; 175 W, 250 W, 400 W MH V. Mogul Base.
NEC:
Class 1, Division 1 and 2, Groups C, D
Marine Type Electric Fixtures
Outside Type (Salt Water)
CEC: V
Class I, Division 1 and 2, Groups B, C, D
Class II, Division 1, Groups E, F, G
Class II, Division 2, Groups F, G
Class III
CSA 4X
Applications
• UL Listed for Marine Type Electric Fixtures Outside Type (Salt
Water).
• Ideal in Class I, Division 1 and 2 installations in refineries, in
pipeline transportation facilities, at drilling rigs and in production
facilities on land and marine platforms.
• Class I, Division 1 areas include:
(1) enclosed derricks, mud tanks, desander-desilter, gasoperated control devices, oil-gas separation vessels, shale
shakers and flowing or beam wells
(2) flowing or beam wells in open areas with cellar or below
grade sump
(3) on refinery docks where tankers are loaded with hoses or
loading arms
(4) in compressor buildings (open or enclosed) where methane
gas is present
• Virtually all enclosed areas at drilling operations or refineries
where ventilation is inadequate, or where a cellar or below grade
sump exists, are Class I, Division 1.
Shown with Optional High Bay Reflector
Features
Effective Protected area: 1.8 Square Feet
Options
• Fuses for field installation are ordered by catalog number from
the fuse kit table
• Quartz Auxiliary Emergency Lamp for PSMH and HPS fixtures.
Relay switch installed fixture. Add suffix -E to fixture catalog
number.
• “Smart Hot Restrike” Emergency Option available for 150 W
HPS. Add suffix -SR.
• Hot Restrike Option available for 150 W HPS. Add suffix -R.
• Smart Starter. Add suffix -S
Certifications and Compliances
•
•
•
•
UL Standard: UL 1598, UL 844
UL Listed: E10444
CSA Standard: C22.2 No. 250, C22.2 No. 137
CSA Certified: 025428
Lighting: Explosionproof — Floodlight
• Choice of mountings: (1) crossarm with degree indicator; (2)
junction box for horizontal or vertical mount; and (3) swivel for
pole mount (screws onto standard 2” pipe threads).
• Fixtures operate safely in high ambient temperatures. For
example, in Class I areas the 150 W HPS unit operates at a
maximum fixture surface temperature of 248 °F/120 °C in a
149 °F/65 °C ambient (212 °F/100 °C temperature in a 104 °F/
40 °C ambient).
• Arrangement of heat-producing components results in more
efficient heat dissipation for cooler fixture operation.
• All threaded joints are flame-tight.
• Five threads are always fully engaged in an
explosionproof manner.
• Factory sealed. External seals not required.
• Strategic location of lamp socket, in combination with the
interior prism design of the glass globe, provides optimum light
distribution and control.
• Heat- and impact-resistant globes have smooth
dust-resistant exterior.
• Superior corrosion resistance, with epoxy powder coat finish.
• Ballasts operate at low temperatures – PSMH: -20 °F/-29 °C;
HPS: -40 °F/ -40 °C.
Standard Materials
• Ballast housing, guard and junction box, and pole mounts:
copperfree (4/10 of 1% max.) aluminum
• Crossarm mount: malleable iron
• Trunnion: steel.
• High bay reflector: aluminum
• Standard dome, deep dome and 30° angle reflectors:
fiberglass reinforced polyester
• Socket: porcelain
• Screw shell: nickel-plated phosphor bronze
Standard Finishes
• Ballast housing, guard, trunnion and mounting accessories:
epoxy-clad finish. Powder coat baked finish, electrostatically
applied for complete, uniform corrosion protection
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
Lighting
V CSA Certification only.
1289
Code•Master 2™ HID Factory Sealed Floodlights
Marine (Outside Type). Explosionproof
Integrally Ballasted. 150 W, 250 W, 400 W HPS; 150 W, 175 W, 250 W, 320 W, 350 W, 400 W PSMH; 175 W, 250 W, 400 W MH V. Mogul Base.
NEC:
Class 1, Division 1 and 2, Groups C, D
Marine Type Electric Fixtures
Outside Type (Salt Water)
CEC: V
Class I, Division 1 and 2, Groups B, C, D
Class II, Division 1, Groups E, F, G
Class II, Division 2, Groups F, G
Class III
CSA 4X
Classified Area Suitability — Suitability includes use of reflector
Lamp
Type
High Pressure
Sodium
Pulse Start
Metal Halide
Supply Wire
(°F/˚°C)
Ambient Temp
(°F/°˚C)
150
122/60
104/40
T5
C,D
Class II, Division 1 & 2
With Globe or with Globe & Reflector
CEC Temp. Ident. No.
Nameplate
CEC V
Marking
Groups
B, C, D
T3A
E,F
150
167/75
131/55
—
C,D
B, C, D
T3
—
250
167/75
104/40
T4
C,D
B, C, D
—
—
250
167/75
131/55
—
C,D
B, C, D
—
—
400
185/85
104/40
T3A
C,D
B, C, D
—
—
175
167/75
104/40
T3B
C,D
B, C, D
T3C
E,F,G
250
167/75
104/40
T3B
C,D
B, C, D
T3A
E,F
320
167/75
104/40
T3
C,D
B, C, D
—
—
350
167/75
104/40
T3
C,D
B, C, D
—
—
400
167/75
104/40
T3
C,D
B, C, D
—
—
175
167/75
104/40
T4
—
B, C, D
T3C
E, F, G
250
167/75
104/40
T4
—
B, C, D
T3A
E, F
400
167/75
104/40
T3C
—
B, C, D
—
—
Lighting
Lighting: Explosionproof — Floodlight
Metal Halide V
Lamp
Watts
Class I, Division 1 & 2 With Globe or with
Globe & Reflector UL/NEC/CEC Temp. Ident. No.
Nameplate
NEC
CEC V
Marking
Groups
Groups
V CSA Certification only.
1290
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
Code•Master 2™ HID Factory Sealed Floodlights
Marine (Outside Type). Explosionproof
Integrally Ballasted. 150 W, 250 W, 400 W HPS; 150 W, 175 W, 250 W, 320 W, 350 W, 400 W PSMH. Mogul Base.
NEC:
Class 1, Division 1 and 2, Groups C, D
Marine Type Electric Fixtures
Outside Type (Salt Water)
Lamp
Watts
ANSI Lamp Type
HPS
PSMH
HPS
Catalog Number ➊➌
PSMH
Fixture Unit
Furnished with Trunnion 3/4” hub. (3/4 – 14 NPT)
150
175
250
320
350
400
S55
—
S50
—
—
S51
M102
M137/M152
M138/M153
M145
M131
M135/M155
CFL150MT
—
CFL250MT
—
—
CFL400MT
CFP150MT
CFP175MT
CFP250MT
CFP320MT
CFP350MT
CFP400MT
Fixture Unit with Junction Box for Horizontal or Vertical Mounting ➋
3/4” fixture hub and two conduit openings (3/4 – 14 NPT). 30” Flexible Coupling connects to 3/4” fixture hub
and to 1/2” junction box opening. Furnished with one 3/4” Close-up Plug. Has Locking Screw for horizontal
adjustment.
150
175
250
320
350
400
S55
—
S50
—
—
S51
M102
M137/M152
M138/M153
M145
M131
M135/M155
CFL150JBMT
—
CFL250JBMT
—
—
CFL400JBMT
CFP150JBMT
CFP175JBMT
CFP250JBMT
CFP320JBMT
CFP350JBMT
CFP400JBMT
Fixture Unit with Pole-Top Mount (on 2” Threaded Pipe) ➋
2” tapered threads (2 – 11-1/2 NPT). Locking Screw for horizontal adjustment. 30” Flexible Coupling connects
to 3/4” fixture hub (3/4 – 14 NPT) and to 1/2” pole-top opening (1/2-14 NPT).
150
S55
M102
CFL150SFMT
CFP150SFMT
175
—
M137/M152
—
CFP175SFMT
250
S50
M138/M153
CFL250SFMT
CFP250SFMT
320
—
M145
—
CFP320SFMT
350
—
M131
—
CFP350SFMT
400
S51
M135/M155
CFL400SFMT
CFP400SFMT
For mounting to flat surface. 180° horizontal adjustment with degree indicator. 30” Flexible Coupling connects
to 3/4” fixture hub (3/4 – 14 NPT) and to any 1/2” opening (1/2 – 14 NPT).
150
175
250
320
350
400
S55
—
S50
—
—
S51
M102
M137/M152
M138/M153
M145
M131
M135/M155
CFL150CAMT
—
CFL250CAMT
—
—
CFL400CAMT
CFP150CAMT
CFP175CAMT
CFP250CAMT
CFP320CAMT
CFP350CAMT
CFP400CAMT
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
1291
Lighting
➊ To order fixture with guard, add suffix -G before voltage suffix.
➋ Fixtures furnished with trunnion and bolts, flexible coupling and fittings, and mounting accessory. The trunnion provides vertical adjustment and the mounting
accessory provides horizontal adjustment.
➌ Change suffix -MT (120/208/240/277 V) to -480 for 480 V.
Lighting: Explosionproof — Floodlight
Fixture Unit with Crossarm Mounting ➋
Code•Master 2™ HID Factory Sealed Floodlights V
Marine (Outside Type). Explosionproof
Integrally Ballasted. 150 W, 250 W, 400 W HPS; 150 W, 175 W, 250 W, 320 W, 350 W, 400 W PSMH; 175 W, 250 W, 400 W MH. Mogul Base.
CEC: V
Class I, Division 1 and 2, Groups B, C, D
Class II, Division 1, Groups E, F, G
Class II, Division 2, Groups F, G
Class III
CSA 4X
Lamp
Watts
HPS
ANSI Lamp Type
PSMH
MH
HPS
Catalog Number ➊➌
PSMH
MH
Fixture Unit
Furnished with Trunnion 3/4” hub. (3/4 – 14 NPT)
150
175
250
320
350
400
S55
—
S50
—
—
S51
M102
M137/M152
M138/M153
M145
M131
M135/M155
—
M57/H39
M58/H37
—
—
M59/H33
CFL150TTCN
—
CFL250TTCN
—
—
CFL400TTCN
CFP150TTCN
CFP175TTCN
CFP250TTCN
CFP320TTCN
CFP350TTCN
CFP400TTCN
—
CFH175TTCN
CFH250TTCN
—
—
CFH400TTCN
Fixture Unit with Junction Box for Horizontal or Vertical Mounting ➋
3/4” fixture hub and two conduit openings (3/4 – 14 NPT). 30” Flexible Coupling connects to 3/4” fixture hub
and to 1/2” junction box opening. Furnished with one 3/4” Close-up Plug. Has Locking Screw for horizontal
adjustment.
150
175
250
320
350
400
S55
—
S50
—
—
S51
M102
M137/M152
M138/M153
M145
M131
M135/M155
—
M57/H39
M58/H37
—
—
M59/H33
CFL150JBTTCN
—
CFL250JBTTCN
—
—
CFL400JBTTCN
CFP150JBTTCN
CFP175JBTTCN
CFP250JBTTCN
CFP320JBTTCN
CFP350JBTTCN
CFP400JBTTCN
—
CFH175JBTTCN
CFH250JBTTCN
—
—
CFH400JBTTCN
Fixture Unit with Pole-Top Mount (on 2” Threaded Pipe) ➋
Lighting
Lighting: Explosionproof — Floodlight
2” tapered threads (2 – 11-1/2 NPT). Locking Screw for horizontal adjustment. 30” Flexible Coupling connects
to 3/4” fixture hub (3/4 – 14 NPT) and to 1/2” pole-top opening (1/2-14 NPT).
CFL150SFTTCN
CFP150SFTTCN
150
S55
M102
—
175
—
M137/M152
M57/H39
250
S50
M138/M153
M58/H37
320
—
M145
—
—
CFP320SFTTCN
—
350
—
M131
—
—
CFP350SFTTCN
—
400
S51
M135/M155
M59/H33
—
CFL250SFTTCN
CFL400SFTTCN
—
CFP175SFTTCN
CFH175SFTTCN
CFP250SFTTCN
CFH250SFTTCN
CFP400SFTTCN
CFH400SFTTCN
Fixture Unit with Crossarm Mounting ➋
For mounting to flat surface. 180° horizontal adjustment with degree indicator. 30” Flexible Coupling connects
to 3/4” fixture hub (3/4 – 14 NPT) and to any 1/2” opening (1/2 – 14 NPT).
150
175
250
320
350
400
S55
—
S50
—
—
S51
M102
M137/M152
M138/M153
M145
M131
M135/M155
—
M57/H39
M58/H37
—
—
M59/H33
CFL150CATTCN
—
CFL250CATTCN
—
—
CFL400CATTCN
CFP150CATTCN
CFP175CATTCN
CFP250CATTCN
CFP320CATTCN
CFP350CATTCN
CFP400CATTCN
—
CFH175CATTCN
CFH250CATTCN
—
—
CFH400CATTCN
➊ To order fixture with guard, add suffix -G before voltage suffix.
➋ Fixtures furnished with trunnion and bolts, flexible coupling and fittings, and mounting accessory. The trunnion provides vertical adjustment and the mounting
accessory provides horizontal adjustment.
➌ Change voltage suffix -TT (120/277/347 V) to -MT for 120/208/240/277 V, -C2 for 208 V, -C3 for 240 V, -C6 for 480 V, or -C7 for 600 V, V
V CSA Certification only.
1292
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
Code•Master 2™ HID Factory Sealed Floodlight Accessories
Marine (Outside Type). Explosionproof
Integrally Ballasted. 150 W, 250 W, 400 W HPS; 150 W, 175 W, 250 W, 320 W, 350 W, 400 W PSMH; 175 W, 250 W, 400 W MH V. Mogul Base.
Description
Junction Box for Horizontal or Vertical Mounting
Box has 1/2” opening for threading to Flexible Coupling, and two 3/4”
conduit openings (3/4 – 14NPT) and is furnished with one 3/4” close-up
plug. Locking screw for horizontal adjustment. Trunnion bolts furnished.
Aluminum, gray epoxy finish.
Catalog Number
AF-JB
Pole-Top Mount (on 2” Threaded Pipe)
Threads onto 2” pipe with tapered threads (2-11 – 1/2 NPT). Includes
floodlight trunnion bolts. Locking screw for horizontal floodlight
adjustment. Aluminum, gray epoxy finish.
AF-SF
Has 180° horizontal adjustment – degree-marked. Facilitates mounting
floodlight to crossarm or other flat surface, or to G-AM-8-WB Pole/Wall
Mounting Bracket (see photo below). Includes floodlight trunnion bolts.
Malleable iron, plated, chromate sealed, architectural bronze EPOXY finish.
G-AM-8-CA
Crossarm Mounting Bracket
Polyester Reflectors – 150 W through 400 W
Standard Dome
Deep Dome
30° Angle
CMR-4ST
CMR-4DD
CMR-4AN
Aluminum High Bay Reflectors – 150 W through 400 W
CMR-4HB
Flexible Coupling – 30” Long
Connects to 3/4” Fixture Unit hub (3/4 – 14 NPT) and to 1/2”
Junction Box or Pole-Top Accessory opening (1/2 – 14 NPT).
AF-EXL
Quartz Emergency Lamp for Pulse Start Metal Halide and High Pressure Sodium Fixtures
Fixtures can be supplied with a socket to accept a 150 W or 250 W, 120 V quartz lamp.
This D.C. bayonet base socket is in addition to the standard lamp socket, independent of the lighting fixture voltage.
Lighting
V CSA Certification only.
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
Lighting: Explosionproof — Floodlight
-E
HPS Smart Hot Restrike
Smart Hot Restrike will immediately restrike an HPS lamp when power is restored after a momentary power interruption.
The smart function removes the hot restrike ignitor from the circuit if the lamp burns out or is removed from the socket.
Eliminates starter failures caused by prolonged operation with cycling or failing lamps and simplifies finding their location,
reducing maintenance and repair costs.
Optional for 150 W fixtures (HPS only)
Add Suffix -SR
HPS Hot Restrike
Restrikes HPS lamp immediately when power is restored after a momentary power interruption.
Optional for 150 W fixtures (HPS only)
Add Suffix -R
HPS Smart Starter
Smart Starter for HPS and PSMH fixtures. Incorporates a 1-1/2-minute timer and performs as a conventional starter to normally
start lamp. Removes itself from circuit if lamp burns out or is removed from socket. Eliminates starter failures caused by
prolonged operation with cycling or failing lamps and simplifies finding their location, reducing maintenance and repair costs.
Optional for all fixture watts
Add Suffix -S
G-AM-8-CA Crossarm Mounting Bracket
Shown with G-AM-8-WB Pipe/Wall Mounting Bracket.
The G-AM-8-WB bracket is not furnished with fixtures.
1293
Code•Master 2™ HID Factory Sealed Floodlight Ballast and Fuse Data
Marine (Outside Type). Explosionproof
Integrally Ballasted. 150 W, 250 W, 400 W HPS; 150 W, 175 W, 250 W, 320 W, 350 W, 400 W PSMH; 175 W, 250 W, 400 W MH V. Mogul Base.
NEC:
Class 1, Division 1 and 2, Groups C, D
Marine Type Electric Fixtures
Outside Type (Salt Water)
Lamp
Watts
150
175
250
320
350
Ballast Amps
Pulse Start Metal Halide
Super CWA
Start
Operating
—
—
—
—
—
—
—
—
—
—
—
—
1.10
1.86
0.75
1.23
0.65
0.98
0.55
0.87
0.25
0.65
0.25
0.50
1.96
2.50
1.13
1.45
0.98
1.25
0.85
1.10
0.62
0.90
0.32
0.67
3.30
3.25
1.90
1.90
1.60
1.65
1.40
1.40
0.70
1.10
0.45
0.85
3.60
3.70
2.10
2.10
1.80
1.80
1.60
1.60
0.70
1.01
0.60
0.90
3.50
4.00
2.00
2.30
1.75
2.00
1.75
1.50
1.10
1.35
0.75
1.00
Metal Halide
CWA
Start
Operating
—
—
—
—
—
—
—
—
—
—
—
—
1.30
1.80
0.75
1.10
0.65
0.90
0.55
0.80
0.50
0.65
—
—
1.20
2.60
0.65
1.50
0.60
1.30
0.50
1.12
0.80
0.90
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
3.25
4.00
1.90
2.30
1.65
2.00
1.40
1.75
1.20
1.40
—
—
Fuse Kit Catalog Number
Fuse
Quantity
Required
1
2
2
1
1
2
1
2
2
1
1
2
1
2
2
1
1
2
1
2
2
1
1
2
1
2
2
1
1
2
1
2
2
1
1
2
HPS
CF-10
CF-5
CF-5
CF-5
CF-5
CF-3
—
—
—
—
—
—
CF-8
CF-5
CF-5
CF-5
CF-5
CF-2
—
—
—
—
—
—
—
—
—
—
—
—
CF-15
CF-8
CF-5
CF-5
CF-5
CF-5
PSMH
—
—
—
—
—
—
CF-5
CF-3
CF-3
CF-2
CF-2
CF-2
CF-8
CF-5
CF-5
CF-3
CF-3
CF-2
CF-8
CF-6
CF-5
CF-5
CF-5
CF-3
CF-10
CF-8
CF-5
CF-5
CF-5
CF-3
CF-10
CF-8
CF-5
CF-5
CF-5
CF-3
MH
—
—
—
—
—
—
CF-5
CF-3
CF-3
CF-2
CF-2
—
CF-8
CF-5
CF-5
CF-3
CF-3
—
—
—
—
—
—
—
—
—
—
—
—
—
CF-10
CF-8
CF-5
CF-5
CF-5
—
Lighting
Lighting: Explosionproof — Floodlight
400
Volts
120
208
240
277
347
480
120
208
240
277
347
480
120
208
240
277
347
480
120
208
240
277
347
480
120
208
240
277
347
480
120
208
240
277
347
480
High Pressure
Sodium ➊
Start
Operating
2.00
1.66
1.16
0.96
1.00
0.83
0.88
0.75
0.52
0.56
0.50
0.44
—
—
—
—
—
—
—
—
—
—
—
—
1.75
2.70
1.00
1.50
0.85
1.30
0.75
1.15
0.60
0.93
0.40
0.65
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
3.10
3.90
1.80
2.25
1.60
1.95
1.35
1.70
1.00
1.32
0.80
1.00
CEC: V
Class I, Division 1 and 2, Groups B, C, D
Class II, Division 1, Groups E, F, G
Class II, Division 2, Groups F, G
Class III
CSA 4X
Fuse Kit includes fuse, fuse holder and necessary hardware for field installation. Mounts easily in ballast body with one screw. Order one fuse for 120 and 277 V,
and 2 fuses for 208, 240 and 480 V. CF-2 = 2 amp; CF-3 = 3 amp; CF-5 = 5 amp; CF-6 = 6 amp; CF-8 = 8 amp; CF-10 = 10 amp
➊ 50 through 150 W HPS have H.P.F. High Reactance ballasts; 250 W and 400 W HPS have CWA ballasts.
V CSA Certification only.
1294
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
Code•Master 2™ HID Factory Sealed Floodlight Dimensions
Marine (Outside Type). Explosionproof
Integrally Ballasted. 150 W, 250 W, 400 W HPS; 150 W, 175 W, 250 W, 320 W, 350 W, 400 W PSMH; 175 W, 250 W, 400 W MH V. Mogul Base.
Dimensions in Inches/Millimeters
2.95"/
74.9 mm
3.25"/
82.6 mm
2.38"/
60.5 mm
4.75"/
120.7 mm
4.75"/
120.7 mm
5.70"/
144.8 mm
5.00"/
127 mm Dia.
5.65"/
143.5 mm
4.94"/
125.5 mm
2.38"/
60.5 mm
36.44"/
925.6 mm
16.44"/
417.6 mm
15.94"/
404.9 mm
3.50"/
88.9mm
5.00"/
127 mm
11.50"/
292.1 mm
1.75"/
44.5 mm
/
80"
20..3 mm
528
1.50"/
38.1 mm
4.44"/
112.8 mm
0"/
13.0 mm
330.2
/
.6" m
23 .4 m
9
/
59 0.6"mm
2 .2
3
52
Lighting: Explosionproof — Floodlight
2.95"/
74.9 mm
18.63"/
473.2 mm
/
.0" m
12 .8 m
4
30
11.5"/
292.1 mm
5.00"/
127 mm Dia.
508 20"/
mm
R
11.50"/
292.1 mm
7.13"/
181.1 mm
53.0"/1346.2 mm Min.
1.75"/
44.5 mm
3.50"/
88.9 mm
2.94"/
74.7 mm Dia.
2.00"/
50.8 mm
13.0"/
330.2 mm
Weights
150 W
175 W
250 W
320 W
350 W
400 W
46 lb/21 kg
46 lb/21 kg
70 lb/32 kg
70 lb/32 kg
70 lb/32 kg
70 lb/32 kg
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
Lighting
V CSA Certification only.
1295
Code•Master 2™ HID Factory Sealed Floodlight Photometric Data
Marine (Outside Type). Explosionproof
Typical Footcandle Values for Iso-Footcandle Curves. Data Based on 400 W HPS (50,000 Lumens) Clear Mogul Base Lamps.
400 W HPS Floodlight at 45° Angle with High Bay Reflector *
Lighting: Explosionproof — Floodlight
Distance in terms of mounting height
400W MH Floodlight at 45° Angle with High Bay Reflector
Mounting
Height
(feet)
15
FOOTCANDLE VALUES FOR ISO-FOOTCANDLE CURVES
A
52.52
B
43.34
C
D
31.00
17.05
E
10.23
F
G
H
I
Mounting
Height
(feet)
4.77
2.43
1.36
0.84
15
A
B
33.97
22.10
C
16.12
D
E
F
G
H
I
9.69
6.40
4.12
2.13
1.13
.67
2.31
1.20
.64
.38
.77
.41
.24
20
29.54
24.38
17.44
9.59
5.75
2.68
1.37
0.77
0.47
20
19.11
12.43
9.07
5.45
3.60
25
18.91
15.60
11.16
6.14
3.68
1.72
0.87
0.49
0.30
25
12.23
7.96
5.80
3.49
2.30
1.48
30
13.13
10.84
7.75
4.26
2.56
1.19
0.61
0.34
0.31
30
8.49
5.52
4.03
2.42
1.60
1.03
.53
.28
.17
35
9.65
7.96
5.69
3.13
1.88
0.88
0.45
0.25
0.15
35
6.24
4.06
2.96
1.78
1.18
.76
.39
.21
.12
40
7.39
6.10
4.36
2.40
1.44
0.67
0.34
0.19
0.12
40
4.78
3.11
2.27
1.36
.90
.58
.30
.16
.10
45°
45°
MH
MH
1.0MH
Lighting
FOOTCANDLE VALUES FOR ISO-FOOTCANDLE CURVES
1.0MH
* For 250 Watt HPS Clear, 30,000 Lumen lamp, multiply all FTC values by 0.60
1296
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
EFL Series HID and Quartz Floodlights V
cCSAus. Explosionproof
Class I, Zone 1 & 2
Ex de IIB T1/T2/T3
Class I, Zone 1 & 2,
AEx de IIB T1/T2/T3
IP66 / 67
Applications
• Designed for large area lighting in industrial outdoor and indoor
explosionproof areas.
• Ideal for use in Zone 1 and 2 applications in the oil and gas
industry in such areas as refineries, pipelines and offshore
drilling rigs.
Features
• Fast and easy tubular lamp replacement via threaded entry at
the end of the fixture. Suitable for HPS and HPI-T MH lamps
only. Other lamps require lens cover removal for servicing.
• Lamp holder can be easily field adjusted for either a narrow or
wide beam type.
• Thermally separated ballast provides for extended life.
• Easy, efficient wiring process due to a separate Ex-e terminal
chamber.
• Choice of mounting with a galvanized yoke bracket, fixed
horizontal brackets, two different sizes of tube/pole mount
brackets or without brackets for custom installation.
• Tempered safety glass lens is factory sealed into the cover
frame.
• Suitable for use in up to 131 °F/55 °C ambient temperatures.
• 2 – M20 threaded cable entries for ease of wiring. Supplied c/w
one close-up plug and one Ex-e non-armored cable gland.
• One external 4mm2 and one 6mm2 earth/ground terminals.
• Universal mounting for vertical or horizontal positioning.
• Reversible hinge allows for fixture access from either side.
• Mogul Base Lamp is supplied as standard. Optional export
version would be supplied with E40 export socket.
• Highly polished internal Aluminium reflector.
Options
• Overhead diffuser. Black painted, galvanized steel. Suffix –D.
• Protective wire guard. Zinc plated steel. Suffix –G.
• Hot Restrike Igniter. Ignites a hot lamp shortly after a power dip
or outage extinguishes the lamp. Suffix –R.
• Safety Starter. Shuts off device in the event of a lamp failure.
Suffix –S.
• Additional wiring terminals. For 3 Phase loop in/out. Suffix –T.
Certifications and Compliances
• cCSAus: LR25428
Standard Materials
•
•
•
•
Housing and door: copperfree marine grade aluminum alloy
Lens: tempered safety glass
Reflector: highly polished aluminium
Closure bolts: 316 stainless steel
Standard Finishes
• Exterior finish: Housing and door: gray polyester epoxy.
EFL
H
EFL Series:
Explosionproof
Floodlights
40
Wattage:
10 - 1000W Quartz Halogen
15 - 150W HPS/MH
17 - 175W MH/PSMH
20 - 200W PSMH
25 - 250W HPS/MH
40 - 400W HPS/MH
50 - 500W Quartz Halogen
Lamp Type:
H - Metal Halide/ Mercury Vapor
L - High Pressure Sodium
P - Pulse Start Metal Halide
Q - Halogen
B
TT
L
HID Ballast Type & Voltage
TT - CWA for 120/277/347V
MT - CWA for 120/208/240/277V
XP - CWA for 120/220-240V 50 Hz
C5 - CWI for 480V
C6 - CWI for 600V
A1 - No Ballast - Quartz Only
Mounting:
Accessory Options:
B - Galvanized Yoke Bracket (Std. Offering)
D - Overhead Diffuser
H - Set of Horizontal Fittings
G - Protective Wire Guard
C1 - Clamp Bracket. For 1-1/4” – 1-1/2” Tube
L - Lamp Included (HIDOnly)
C2 - Clamp Bracket. For 2” Tube
R - Protected Hot R Strike
N - No Mounting Hardware Supplied
S - Safety Starter (not required
with R)
Lighting
V cCSAus Certification.
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
Lighting: Explosionproof — Floodlight
Catalog Numbering Guide
1297
EFL Series HID and Quartz Floodlights V
cCSAus. Explosionproof
Class I, Zone 1 & 2
Ex de IIB T1/T2/T3
Class I, Zone 1 & 2,
AEx de IIB T1/T2/T3
IP66 / 67
T Code
T Code
104 °F/40 °C
131 °F/55 °C
Input Voltages
Fixture
Wt.
Vol.
Catalog
Number
150 W
T3
T3
120/277/347 V 60Hz
60
3
EFLH15B-TTCN *
250 W
T3
T3
120/277/347 V 60Hz
62
3
EFLH25B-TTCN
400 W
T3
T3
120/277/347 V 60Hz
66
3
EFLH40B-TTCN
175 W
T3
T3
120/277/347 V 60Hz
62
3
EFLP17B-TTCN *
200 W
T3
T3
120/277/347 V 60Hz
62
3
EFLP20B-TTCN *
250 W
T3
T3
120/277/347 V 60Hz
25
3
EFLP25B-TTCN *
400 W
T3
T3
120/277/347 V 60Hz
66
3
EFLP40B-TTCN *
150 W
T3
T3
120/277/347 V 60Hz
60
3
EFLL15B-TTCN
250 W
T3
T3
120/277/347 V 60Hz
62
3
EFLL25B-TTCN
400 W
T3
T3
120/277/347 V 60Hz
66
3
EFLL40B-TTCN
Lamp sockets rated
125-250 Vac
71
3
EFLQ50B-A1CN
71
3
EFLQ10B-A1CN
Fixture Ordering
Supplied Std. w/ Yoke Mtg.
Metal Halide/Mercury Vapor
Pulse Start Metal Halide
High Pressure Sodium
Tubular Quartz Halogen
500 W
T1
T1
1000 W
T1
T1
Voltages — Add Suffix Below to Catalog Number
Volts
120
208
220
240
277
347
480
CWA
-MT
-MT
-
-MT
-MT
-
CWI
-C1
-C2
-
-C3
-
-C5
-C6
50 Hz CWA
-XP
-
-XP
-XP
-
-
-
-A6
600
‡
-C7
Lighting: Explosionproof — Floodlight
Accessories and Replacement Parts
Size
In/mm
Catalog Number
Galvanized Steel Hinged Bracket
Catalog Number
Clip on Diffuser
PNTB1
Pole Mounting Brackets
PND1
Protective Guard
1-1/4” to 1-1/2”/
31.8 mm to 38.1 mm
PNPB115
2”/50.8 mm
PNPB120
PNG1
Horizontal Fixed Mounting Bracket
Lighting
PNHB1
* Depending on availability of tubular type lamps, may require removal of lens cover for servicing.
‡ Supplied as export voltage only. Not suitable for CEC applications
V cCSAus Certification.
1298
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
EFL Series HID and Quartz Floodlight Dimensions and Photometric Data V
cCSAus. Explosionproof
Dimensions in Inches/Millimeters
6.25”/
158.8 mm
16.77”/426.0 mm
13.45”/341.6 mm
28.54”/724.9 mm
Photometric Data
Polar curves for a 1000 lm flux, according to NF C 71-120
Luminaire symbol according to NF C 71-121
250W halide Narrow Beam
Efficiency 68.3%
NF C 71-121: 0,68B
250W halide Wide Beam
Efficiency 67.9%
NF C 71-121: 0,68C
Candela
Distribution
0-180 90-270
505
505
515
499 150° 120°
512
469
501
403
476
312
453
248
427
190
394
146
368
117
290
97
160
12
51
7
15°
34
4 0°
15
4
6
4
400W halide Narrow Beam
Efficiency 49.3%
NF C 71-121: 0,49C
Candela
Distribution
105°
90°
75°
60°
45°
30°
0
5
10
15
20
25
30
35
40
45
50
55
60
65
70
0-180 90-270
301
301
303
318 150° 120°
299
342
294
387
287
382
286
306
271
237
231
208
172
186
133
140
83
104
48
18
15°
34
8 0°
23
6
6
6
400W halide Wide Beam
Efficiency 46.7%
NF C 71-121: 0,46C
Candela
Distribution
105°
90°
75°
60°
45°
30°
0
5
10
15
20
25
30
35
40
45
50
55
60
65
70
0-180 90-270
217
217
210
219 150° 120°
218
231
223
205
238
193
255
148
266
132
263
130
244
116
201
104
136
37
85
15
15°
51
8 0°
28
6
5
4
Candela
Distribution
105°
90°
75°
60°
45°
30°
0
5
10
15
20
25
30
35
40
45
50
55
60
65
70
0-180 90-270
105
105
104
106 150° 120°
108
130
124
165
148
177
167
183
165
147
142
127
116
113
74
115
52
103
48
40
15°
44
13 0°
34
9
18
6
105°
90°
75°
60°
45°
30°
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
Lighting
* 400 W MH: Efficiency rate lower than 250 W due to thermal deflector between glass and lamp, requested for T3.
V cCSAus Certification.
Lighting: Explosionproof — Floodlight
0
5
10
15
20
25
30
35
40
45
50
55
60
65
70
Longitudinal
Transverse
1299
PB, PC & PL Series
Floodlights – Flameproof
Zone 1 & 2 - 21 & 22
II 2 GD
ATEX / IECEx
IP66 or IP66/67 - IK10
Applications
• Designed for large area lighting in industrial outdoor and indoor
hazardous areas.
• Ideal for use in Zones 1 and 2 and 21 and 22 in the oil and gas
industrysuch as: refineries, pipelines, warehouses, offshore
platforms and drilling rigs.
Type PB
Lighting: Explosionproof — Floodlight
Features
• Gray epoxy painted light marine grade aluminum housing
and door.
• Fast and easy lamp replacement via threaded cover on the
side of the fixture (Types PB and PC). The cover is fitted with
a short safety chain.
• Lampholder can be easily field-adjustable for either a narrow
or wide beam.
• Fixtures operate safely in high ambient temperatures up
to +131°F/55°C and in low ambient temperature up to -40 °F/40 ºC (-13 °F/-25 ºC for PC type and -40 °F/-40 ºC for PL type).
• Electrical components (ballast, ignitor and capacitor) are
thermally separated from the lighting compartment with a
bulkhead (Type PB) or with an insulating protection
(Types PC and PL), providing extended life.
• Easy and efficient wiring due to separate Ex e terminal box
with wiring onto 2 captive terminals 2 x .009 in²/6 mm2; 2
internal earth terminals capacity .009 in2/6 mm2 and 1 external
earth terminal capacity .006" in²/4 mm2.
• 2 x .79"/20 mm clearance holes throughwire cable entries
supplied with:
— One Ex e unarmored cable gland
(sealing dia. .26" to .57"/6.5" to 14.5 mm)
— One blanking plug
— Two M20 locknuts.
• For use with either tubular or ellipsoidal shape lamps.
See ordering information for details.
• Choice of mounting with galvanized hinged bracket fixed
mounting or tube/pole mounting with galvanized brackets.
• Toughened glass factory-sealed into the floodlight body
(Types PC and PL) or factory-sealed into the cover frame
(Type PL).
• Operates in any position (except Type PL, to be used only
for wall-mounting or down lighting applications).
• Reversible hinge allows for fixture access from either side.
• E40 or H3 lampholders for the 2 x 70 W Vac/Vdc
halogen version.
• Internal symmetric reflector.
Standard Materials
• Housing and door: copperfree marine-grade aluminum
alloy
• Lens: toughened safety glass
• Reflector: bright highly polished aluminum
• Bolts: stainless steel bolt
• Cable gland and blanking plug: polyamide
• Locknut: nickel plated brass
Standard Finishes
• Housing and door: gray epoxy powder paint
Type PC
• Screwed-on overhead diffuser out of galvanized steel with
black painting (see accessories).
• Screwed-on zinc-coated protection guard for Types PB and PC
(see accessories).
• 1000 W HP Sodium (Type PL) with separate Ex d housing
for ballast.
Certifications and Compliances
•
•
•
•
•
•
•
•
•
•
•
•
•
•
Certification Type: PJd
Zone 1 - 2
— Conforming to ATEX 94/9/CE: CE 0081
II 2 G
— ATEX/IEC Protection: Ex de IIB (Type PB et PL)
Ex de IIC (Type PC)
— T Rating: See Tables
Zone 21 - 22
— Conforming to ATEX 94/9/CE: CE 0081
II 2 D
— ATEX/IEC Protection: Ex tD A21
— Surface Temperature: See tables
Ambient Temperature: -4 °F/-20 °C ≤ Ta ≤ +131 °F/55 °C (Type
PB and PC) (-13 °F/-25 °C for PC Type as an option) -40 °F/-40
°C ≤ Ta ≤ +131 °F/55 °C (Type PL)
CE Declaration of Conformity: 50207
ATEX Certificate: LCIE 99/ ATEX 6002
IECEx Certificate: IECEx LCI 04.0020
Other Certifications: GOST
Index of Protection (solid & liquid): IP66 (Type PB)
IP66/67 (Types PC and PL)
Impact Resistance (shock): IK10
Ex Standards EN / IEC 60079-0; 60079-1; 60079-7;
61241-0; 61241-1
Product Standards: EN / IEC 60598-1
EMC Standards: EN / IEC 55015; 61547
Other Standards: EN / IEC 60529 (IP); 62262 (IK)
North American CEC/NEC Certification:
•
•
•
AEx/Ex de IIB IP 66 (Type PB only) cCSAus Ex de IIB IP 66
(Type PB only).
175 W Metal Halide and Pulse Start Metal Halide.
Safety starter.
Lighting
Options:
• Other voltages, please contact your sales representative.
• Terminal block with 2 more terminals for wiring with 3 phases
plus Neutral in 380/415 V (loop in/loop out wiring possible): add
suffix -T at the end of the catalog number.
1300
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
PB, PC & PL Series
Floodlights – Flameproof
Zone 1 & 2 - 21 & 22
II 2 GD
ATEX / IECEx
IP66 or IP66/67 - IK10
Order using catalog numbering guide below or select catalog number from tables on following pages.
Catalog Numbering Guide
PB
A
H
Series:
PB - IIB
PC - IIC
PL - IIB Low Temperature
Rating ➍
15
Lamp Type:
H - Metal Halide
L - Sodium
M - Mercury Vapor
Z - Halogen
Zone 1, 2, 21 and 22
ATEX/IEC Certified
XJ
B
Voltage:
XJ - 230/240 Vac 50 Hz (Magnetic Ballast)
XC - 230 Vac 50 Hz (Magnetic Ballast) ➋
XA - 220 Vac 50 Hz (Magnetic Ballast) ➋
BT - 24 Vac/Vdc ➊
Lamp Power:
70 - 2 x 70 W Halogen ➊
15 - 150 W
25 - 250 W
40 - 400 W
50 - 500 or 1000 W Halogen
60 - 600 W ➎
1K - 1000 W ➏
Options:
B - Hinged Bracket
Included
T - Extra
Terminals ➌
C - -25°C Ambient
Temperature ➐
Temperature Rating Chart: Types PB - PC
Lamp Wattage
2 x 70 W - H3 ➊
150 W Sodium
250 W Sodium
250 W Metal Halide
250 W Mercury Vapor
400 W Sodium
400 W Metal Halide
400 W Mercury Vapor
600 W Sodium
500 W Halogen
1000 W Halogen
Gas Temperature Rating According to Ta
+104°F/40°C
+122°F/50°C
+131°F/55°C
T4
T4
T3
T3
T3
T3
T3
T3
T2
T2
T1
T4
T3
T3
T3
T3
T3
T3
T3
T2
T2
T1
T4
T3
T3
T3
T3
T3
T3
T3
T2
T2
T1
Dust
Surface Temperature °F/°C
266/130
293/145
383/195
387/197
381/194
372/189
379/193
383/195
495/257
513/267
712/378
Lamp Wattage
150 W Sodium
250 W Sodium
250 W Metal Halide
250 W Mercury Vapor
400 W Sodium
400 W Metal Halide
400 W Mercury Vapor
600 W Sodium
500 W Halogen
1000 W Halogen
Gas Temperature Rating According to Ta
+104°F/40°C
+122°F/50°C
+131°F/55°C
T4
T3
T3
T4
T3
T3
T3
T3
T3
T3
T3
T3
T4
T3
T3
T3
T3
T3
T3
T3
T3
T2
T2
T2
T2
T2
T2
T1
T1
T1
Lighting: Explosionproof — Floodlight
Temperature Rating Chart: Types PL
Dust
Surface Temperature °F/°C
293/145
293/145
387/197
381/194
291/144
379/193
383/195
495/257
513/267
712/378
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
Lighting
➊ Only for IIB Version - 2 x 70 W Halogen 24 Vac/Vdc.
➋ Only for IIB Low Temperature Rating Version Type PL.
➌ 3 Phase + Neutral.
➍ Only for 250 W and 400 W Versions.
➎ Only Sodium for PC Series (IIC).
➏ Only Sodium for PL Series + Seperate Gear Box.
➐ Only IIC Version.
1301
PB, PC & PL Series
Floodlights – Flameproof
Zone 1 & 2 - 21 & 22
II 2 GD
ATEX / IECEx
IP66 or IP66/67 - IK10
Lamp
Wattages
Lampholder
Voltage
(+/-10%)
Lamp Type
Ellipsoidal Tubular
Weight
lbs/kgs
Volume
in³/dm³
Catalog
Number
Ex de IIB Floodlight - PB Series
High Pressure Sodium
150 W
E40
230/240 V 50 Hz
x
x
65/29.3
4847/79.4
PBAL15XJB
250 W
E40
230/240 V 50 Hz
x
x
67/30.3
4847/79.4
PBAL25XJB
400 W
E40
230/240 V 50 Hz
–
x
70/31.8
4847/79.4
PBAL40XJB
Mercury Vapor
250 W
E40
230/240 V 50 Hz
x
x
65/29.3
4847/79.4
PBAM25XJB
400 W
E40
230/240 V 50 Hz
–
x
66/29.8
484779.4
PBAM40XJB
Metal Halide
250 W
E40
230/240 V 50 Hz
x
x
67/30.3
4847/79.4
PBAH25XJB
400 W
E40
230/240 V 50 Hz
–
x
70/31.8
4847/79.4
PBAH40XJB
–
x
58/26.3
4847/79.4
PBAZ50B
24 Vac/Vdc 50 Hz
–
–
60/27.3
4847/79.4
PBAZ70BTB *
Halogen
500/1000 W
E40
2 x 70 W
H3
Ex de IIC Floodlight - PC Series
High Pressure Sodium
150 W
E40
230/240 V 50 Hz
x
x
64/29.0
6374/104.4 PCAL15XJB
250 W
E40
230/240 V 50 Hz
x
x
66/30.0
6374/104.4 PCAL25XJB
400 W
E40
230/240 V 50 Hz
–
x
71/32.0
6374/104.4 PCAL40XJB
600 W
E40
230/240 V 50 Hz
–
x
77/35.0
6374/104.4 PCAL60XJB
250 W
E40
230/240 V 50 Hz
x
x
66/30.0
6374/104.4 PCAM25XJB
400 W
E40
230/240 V 50 Hz
–
x
67/30.5
6374/104.4 PCAM40XJB
Mercury Vapor
Lighting
Lighting: Explosionproof — Floodlight
Metal Halide
250 W
E40
230/240 V 50 Hz
x
x
66/30.0
6374/104.4 PCAH25XJB
400 W
E40
230/240 V 50 Hz
–
x
71/32.0
6374/104.4 PCAH40XJB
–
x
60/27.0
6374/104.4 PCAZ50B
Halogen
500/1000 W
E40
Ex de IIB Floodlight - PL Series
High Pressure Sodium
250 W
E40
230/240 V 50 Hz
x
x
83/37.5
6374/104.4 PLAL25XJB
400 W
E40
220 V 50 Hz
x
x
83/37.5
6374/104.4 PLAL40XAB
–
x
75/34.0
6374/104.4 PLAZ50B
Halogen
500/1000 W
E40
Note : Floodlights supplied with hinged mounting bracket, 1 plug, 1 M20 cable gland (dia. 0.26” to 0.57”/6.5 to 14.5 mm). Lamps are not included.
* Supplied with 2 x 70 W H3 bulbs, 24 Vac/Vdc
1302
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
PB, PC & PL Series Accessories and Spare Parts
Floodlights – Flameproof
Zone 1 & 2 - 21 & 22
II 2 GD
ATEX / IECEx
IP66 or IP66/67 - IK10
Type
Catalog Number
Galvanized Steel Hinged Brackets
Type PB
PBHBG
Type PL
PLHBG
Type PC
PCHBG
Pole/Tube Mounting Galvanized Steel Brackets
Type PB/PL
Type PC
1-1/4" to 1-1/2"
PNHC49G
2"
PNHC60G
1-1/4" to 1-1/2"
PCHC49G
2"
PCHC60G
Flat Surface Mounting Galvanized Steel Brackets
Type PB/PL
PNSBG
Type PC
PCSBG
Tubular
LM400E40
Type PB
PBGDG
Type PC
PCGDG
Type PB
PBPGZ
Type PC
PCPGZ
Type PC only
PCVG
400 W Mercury Vapor Lamp
Screwed-on Overhead Diffuser
Screwed-on Protective Guard
Lighting: Explosionproof — Floodlight
Visor (secured with 2 screws)
Lighting
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
1303
PB, PC & PL Series Dimensions
Floodlights – Flameproof
Type PB
Type PC
Hinged Bracket Mounting
Hinged Bracket Mounting
16.40"/
416.5 mm
5.91"/
150 mm
10.43"/
265 mm
5.91"/
150 mm
29.53"/
750 mm
16.77"/
426 mm
6.22"/
158 mm
8.58"/
218 mm
11.81"/
300 mm
Flat Surface Mounting
13.43"/
341 mm
14.763"/
375 mm
1.97"/
50 mm
Flat Surface Mounting
Pole Mounting
25.75"/
654 mm
13.66"/
347 mm
Pole Mounting
Flat Surface Mounting
Quick access to
lamp
9.84"/
250 mm
14.90"/378.5 mm
Quick access to
component with
threaded cover
13.92"/353.5 mm
1.97"/
50 mm
4 x Ø0.49"/
12.5 mm
15.95"/396 mm
23.11"/587 mm
15.55"/395 mm
Pole Mounting
Lighting
Lighting: Explosionproof — Floodlight
Type PL
Hinged Bracket Mounting
1304
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
PB, PC & PL Series Photometric Data
Floodlights – Flameproof
Longitudinal
Transverse
Polar curves for a 1000 lm flux, according to NF C 71-120
Luminaire symbol according to NF C 71-121
Narrow beam Metal Halide 250 W
Efficiency 68.3%
NF C 71-121: 0.68B
Narrow beam Metal Halide 400 W
Efficiency 49.3%
NF C 71-121: 0.49C
Candela Distribution
Candela Distribution
0-180 90-270
0-180 90-270
0
505
505
5
515
499
Degrees
10
512
469
15
501
403
20
476
312
25
453
248
30
427
190
35
394
146
40
368
117
45
290
97
50
160
12
55
51
7
60
34
4
65
15
4
70
6
4
0
217
105°
5
90°
10
210
219
Degrees
150° 120°
75°
60°
45°
30°
0°
15°
Wide beam Metal Halide 250 W
Efficiency 67.9%
NF C 71-121: 0.68C
231
15
223
205
20
238
193
25
255
148
30
266
132
35
263
130
40
244
116
45
201
104
50
136
37
55
85
15
60
51
8
65
28
6
70
5
4
0-180 90-270
0
417
105°
5
406
418
Degrees
90°
10
419
399
15
419
330
20
408
266
25
398
218
30
371
177
35
344
142
40
295
115
45
213
98
50
135
12
55
68
7
60
34
4
65
16
3
70
5
3
150° 120°
75°
60°
45°
30°
0°
15°
150° 120°
105°
90°
75°
60°
45°
30°
0°
15°
Candela Distribution
0-180 90-270
0
105
105
Degrees
5
104
106
10
108
130
15
124
165
20
148
177
25
167
183
30
165
147
35
142
127
40
116
113
45
74
115
50
52
103
55
48
40
60
44
13
65
34
9
70
18
6
417
150° 120°
105°
90°
75°
60°
45°
30°
0°
15°
Wide beam Halogen 1000 W
Efficiency 57.7%
NF C 71-121: 0.57C
150° 120°
105°
90°
75°
60°
45°
30°
0°
15°
Candela Distribution
0-180 90-270
0
251
251
Degrees
5
244
255
10
247
272
15
245
293
20
237
306
25
229
262
30
213
213
35
194
188
40
163
161
45
120
133
50
82
105
55
52
18
60
35
8
65
20
5
70
8
5
150° 120°
105°
90°
75°
60°
45°
30°
0°
Lighting: Explosionproof — Floodlight
0
5
10
15
20
25
30
35
40
45
50
55
60
65
70
218
Candela Distribution
Wide beam Metal Halide 400 W
Efficiency 46.7%
NF C 71-121: 0.46C
Candela Distribution
0-180 90-270
301
301
Degrees
303
318
299
342
294
387
287
382
286
306
271
237
231
208
172
186
133
140
83
104
48
18
34
8
23
6
6
6
217
Narrow beam Halogen 1000 W
Efficiency 59.2%
NF C 71-121: 0.59B
15°
Lighting
* 400 W Metal Halide: Efficiency rate lower than 250 W due to thermal deflector between glass and lamp, requested for T3.
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
1305
Explosionproof Floodlights
150 W, 300 W Reflector Incandescent
For 150 W PAR-38 or R-40 reflector lamps:
Class I, Groups C, D
For 300 W R-40 reflector lamps:
Class I, Group D
Applications
• Class I, Groups C and D locations such as aircraft service
areas, oil and gas loading docks, distilleries.
Features
• Floodlights feature rugged, lightweight cast aluminum
construction and are factory wired and sealed — no external
seals are required. Choice of lamp types provides various
distribution patterns. Use medium base 150W PAR-38, R-40 or
300W R40 reflector lamps.
• Easy to carry, portable model with wheelbase has handle for
convenient carrying, built-on wrench allowing 135° vertical
adjustment. Weighs 19 lbs/8.6 kgs.
• External cable on portable wheelbase unit (not furnished)
should be 3-conductor No. 16 A.W.G. type S or SO rubber
covered cable. Service end of cord should be equipped with a
2-wire, 3-pole explosionproof plug for connecting to an
explosionproof receptacle.
• Terminal block has pressure terminal for connecting rubber
covered cable to floodlight. Cable Connector takes a .375”
to .500”/9.5 to 12.7 mm outside diameter cord. Sizes up to
.625”/15.9 mm diameter are available on special order.
• Permanent base model has explosionproof junction wiring
chamber with 3/4”/19.1 mm horizontal feed-thru hubs. Vertical
adjustment to 135°; horizontal to 345°.
GEFWB-30
Standard Materials
• Housing: cast aluminum
• Yoke: high-strength aluminum alloy
• Lens: thermal shock and impact resistant glass
Standard Finishes
• Floodlight housing, wheelbase, yoke and wiring compartment:
aluminum enamel finished
Certifications and Compliances
Lighting
Lighting: Explosionproof — Floodlight
• UL Standard: UL 1598, UL 844
• UL Listed: E10794
• Copperfree aluminum alloy and stainless steel construction
withstands 500 hours of salt-spray test. Per MIL-F-8115C
GEFJB-30
EF Series Explosionproof Floodlights
For 150W incandescent medium base PAR-38 (T3C) projector spot or flood, or 150W or 300W incandescent medium base R-40 (T2C)
reflector spot or flood
Description
Catalog Number
Portable Flood with Wheelbase and Handle. Accommodates .375”—.500”/9.5 mm cable.
G-EFWB-30
Permanent Base Floodlight, for .314”/8.0 mm conduit
G-EFJB-30
†
† Can be furnished to accommodate cable sizes to .625”/15.9mm Dia. on special order. Cable must be ordered separately.
1306
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
Explosionproof Floodlight Dimensions
150 W, 300 W Reflector Incandescent
Dimensions in Inches/Millimeters
Wheelbase Floodlight (GEFWB-30)
Permanent Base Floodlight (GEFJB-30)
13.19"/
335.0 mm
10.5"/
266.7 mm
16.75"/425.5 mm
17.5"/444.5 mm
.75"/19.1 mm Hub each side
12"/
304.8 mm
3.25"/
82.6 mm
4.75"/120.7 mm
5.63"/143.0 mm
Lighting: Explosionproof — Floodlight
2.75"/
69.9 mm
G-EFJB-30
Base Dimensions
Lighting
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
1307
Code•Master™ Factory Sealed Strobe Luminaires
Lighting: Explosionproof — Visual Signal
Lighting
Explosionproof, Dust-Ignitionproof
Class I, Division 1 and 2, Groups C, D
Class I, Division 2, Groups A, B
Class II, Division 1 and 2, Groups E, F, G
Class III
NEMA 3R, 4X
Suitable for Wet Locations
Marine Outside Type (Saltwater)
Applications
• Code•Master Explosionproof Strobe fixtures are designed to
provide safe operation in the presence of hazardous gases,
vapors or dusts, defined by the National Electrical Code as
Class I, Groups C and D; and Class II, Groups E, F and G.
• For use in hazardous locations such as plants where plastics,
paints, thinners and petrochemicals are manufactured.
• Also used in areas where audible signals cannot be heard, to
warn of unsafe conditions and for other communication needs.
Features
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
Fixtures operate safely in high ambient temperatures.
Minimum operating temperature is -13 °F/-25 °C.
Available for fire alarm hearing impaired.
65 flashes per minute.
Fixtures are complete with lamp.
Patented “wireless” design. Threading of fixture unit
onto mounting hood makes electrical connection. The
only wiring required is attaching two wires to connection
block in mounting hood.
Connection block is easily wired: (a) loosen two screws, (b)
make wire connections; and (c) re-position connection block.
Safe, easy servicing without disconnecting any wiring.
“Wireless” fixture unit threads off mounting hood for convenient
servicing or for immediate replacement with a “stand by” unit.
Acme double lead threads speed installation and fixture removal
from mounting hood. Only half as many turns are required as for
single lead threads. The threads do not stick or gall, eliminating
problems often encountered with single lead threads during
fixture unit removal.
All threaded joints are flame-tight.
Factory installed lens available in five colors: red, amber, blue,
green and clear (factory installed).
Factory sealed. External seals are not required.
Heat- and impact-resistant globes have smooth dust-resistant
exterior.
Fixture is suitable for mounting globe up or globe down utilizing
pendant, ceiling or wall bracket type mounts.
Optional guards protect globes from damage.
Fixture (shown with optional guard) are suitable for mounting in
any position including globe up or globe down utilizing pendant,
ceiling or wall-bracket type mounts.
Standard Materials
• Fixture housing, mounting hoods and guards: copperfree (4/10
of 1% max.) aluminum
• Globes: prismatic glass
• Screws: Stainless steel (3)
Standard Finishes
• Fixture housing, guards and mounting hoods: epoxy power
coat finish, electrostatically applied for complete, uniform
corrosion protection
Certifications and Compliances
•
•
•
•
UL Listed: E212210
UL Standard: 1203
UL Standard: 1638 Visual Signaling Appliances
UL Standard: 1971 Visual Signaling Equipment has been
investigated for fire protective signaling services to alert hearing
impaired persons. This signaling equipment is intended to be
used in conjunction with Listed compatible units and devices.
Visual signaling equipment Listed in this category is intended to
be used in the “Public Operating Mode” as defined in NFPA 72
1308
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
Code•Master™ Factory Sealed Strobe Luminaires
Explosionproof, Dust-Ignitionproof
Lighting
Class I, Division 1 and 2, Groups C, D
Class I, Division 2, Groups A, B
Class II, Division 1 and 2, Groups E, F, G
Class III
NEMA 3R, 4X
Suitable for Wet Locations
Marine Outside Type (Saltwater)
Catalog Numbering Guide
CS
S
P
Series:
CS - Code•Master Signal
75
120AC
Mounting Hood:
P - Pendant
B - Wall bracket
C - Ceiling
Type:
S - Strobe
CL
P
Voltage Current:
120 AC - 120 Vac
240 AC - 240 Vac
250 DC - 250 Vdc
2030 DC - 20-30 Vdc ➊
24 DC - 24 Vdc ➌
Hub Size:
75 – 3/4”
Options:
P - Hearing
Impaired
(UL1971)
(Strobe Only)
G - Guard
Globe:
CL - Clear
AM - Amber ➋
BL - Blue ➋
GR - Green ➋
RE - Red ➋
Thermal Suitability of Code-Master Strobe Fixture
Ambient
Temp.
°F/°C
Class I, Division 1 and 2
Groups C & D
Class I, Division 2
Groups A & B
Class II, Division 1 & 2
Class III
104/40
T6
T2B
T4A
131/55
T6
T2B
T4A
149/65
T6
T2A
T4
Operating Temperatures
“T” Numbers Represent the Maximum Internal Temperature for Class I, Division 2 Locations; Maximum Surface Temperature for
Class I, Division 1 Locations; and Maximum Surface Temperature Under Dust Blanket for Class II, Division 1 Locations.
“T”
Number
T1
350
325
T2
T2A
T2B
T2C
T2D
T3
T3A
T3B
T3C
T4
T4A
T5
T6
Temp.
Range
(°F)
664842
619662
574617
538572
502536
448500
421446
394419
358392
331356
322329
277320
250275
214248
187212
185
Temp.
Range
(°C)
351450
326350
301325
281300
261280
231260
216230
201215
181200
166180
161165
136160
121135
101120
86100
85
NOTE: The maximum operating temperature of the fixture must not exceed the ignition temperature of the gas, vapor or dust to be encountered per the National
Electrical Code.
➊ UL1971: Hearing-Impaired Strobe Only
➋ Not for use with UL1971 Strobe
➌ Diode Polarized (Current limiter supplied as standard).
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
1309
Lighting: Explosionproof — Visual Signal
Ordering Information
Order using catalog numbering guide below or select catalog number from tables on following pages.
Code•Master™ Factory Sealed Strobe Luminaires
Lighting: Explosionproof — Visual Signal
Lighting
Explosionproof, Dust-Ignitionproof
Class I, Division 1 and 2, Groups C, D
Class I, Division 2, Groups A, B
Class II, Division 1 and 2, Groups E, F, G
Class III
NEMA 3R, 4X
Suitable for Wet Locations
Marine Outside Type (Saltwater)
Standard Strobes
Volts
Catalog Number ➊➌
Pendant — One Hub 3/4” NPT, Rigid Conduit
120 Vac
CSSP75120ACCL
240 Vac
CSSP75240ACCL
250 Vdc
CSSP75250DCCL
24 Vdc
CSSP7524DCCL ➋
120 Vac
CSSC75120ACCL
240 Vac
CSSC75240ACCL
250 Vdc
CSSC75250DCCL
24 Vdc
CSSC7524DCCL ➋
120 Vac
CSSB75120ACCL
240 Vac
CSSB75240ACCL
250 Vdc
CSSB75250DCCL
24 Vdc
CSSB7524DCCL ➋
120 Vac
CSST120ACCL
240 Vac
CSST240ACCL
250 Vdc
CSST250DCCL
24 Vdc
CSST24PDCCL ➋
Ceiling — Four Hubs 3/4” NPT, Three Close-Up Plugs, Rigid Conduit
Bracket — Four Hubs 3/4” NPT, Three Close-Up Plugs, Rigid Conduit
Fixture Unit Only — Less Mounting Hood
10.3 lb/4.7 kg
Weight
Hub Size (Inches)
Catalog Number
3/4
CAP75
Pendant Mounting Hood — One Hub 3/4” NPT, Rigid Conduit
2.0 lb/9.0 kg
Ceiling Mounting Hood — Four Hubs 3/4” NPT, Three Close-Up Plugs, Rigid Conduit
4.0 lb/1.8 kg
3/4
CAC75
Bracket Mounting Hood — Four Hubs 3/4” NPT, Three Close-Up Plugs, Rigid Conduit
6.0 lb/2.7 kg
3/4
CALB75
➊ Add -G suffix for optional guard.
➋ Diode polarized (current limiter supplied as standard).
➌ Catalog numbers shown are supplied with clear lens. To order colored lens, replace last digits of catalog number CL with AM for amber; BL for blue; GR for
green; and RE for red.
1310
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
Code•Master™ Factory Sealed Strobe Luminaires
Explosionproof, Dust-Ignitionproof
Lighting
Class I, Division 1 and 2, Groups C, D
Class I, Division 2, Groups A, B
Class II, Division 1 and 2, Groups E, F, G
Class III
NEMA 3R, 4X
Suitable for Wet Locations
Marine Outside Type (Saltwater)
Type Mounting
Volts
Catalog Number — UL1971: Hearing-Impaired ➊
20-30 Vdc
CSSP752030DCCLP
20-30 Vdc
CSSC752030DCCLP
20-30 Vdc
CSSB752030DCCLP
10.3 lb/4.7 kg
20-30 Vdc
CSST2030PDCCL
Weight
Hub Size (Inches)
Pendant — One Hub 3/4” NPT, Rigid Conduit
Ceiling — Four Hubs 3/4” NPT, Three Close-Up Plugs, Rigid Conduit
Fixture Unit Only — Less Mounting Hood
Fixture Unit Only — Less Mounting Hood
Catalog Number — UL1971: Hearing-Impaired
Pendant Mounting Hood — One Hub 3/4” NPT, Rigid Conduit
2.0 lb/9.0 kg
3/4
CAP75-1971
Ceiling Mounting Hood — Four Hubs 3/4” NPT, Three Close-Up Plugs, Rigid Conduit
4.0 lb/1.8 kg
3/4
CAC75-1971
Bracket Mounting Hood — Four Hubs 3/4” NPT, Three Close-Up Plugs, Rigid Conduit
6.0 lb/2.7 kg
3/4
CALB75-1971
➊ Only clear globes are available for UL1971 applications.
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
1311
Lighting: Explosionproof — Visual Signal
Strobes for the Hearing Impaired
Code•Master™ Factory Sealed Strobe Luminaire Accessories
Lighting: Explosionproof — Visual Signal
Lighting
Explosionproof, Dust-Ignitionproof
Description
Weight Lbs/Kg
Catalog Number
1.0/0.5
CJGU-15
0.5/0.2
VPT-7
0.5/0.2
VPT-7P
Optional Aluminum Guard
Replacement Connection Block — Standard
For Non-Hearing-Impaired
CodeMaster Fixtures
Replacement Connection Block — UL1971: Hearing-Impaired
For Code-Master Fixtures for the
Hearing Impaired
Replacement Lamps
Fixture Type
Lamp Type
Voltage
Base Type
Catalog Number
Xenon
All
Octal Socket
S865
Strobe
1312
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
Code•Master™ Factory Sealed Strobe Luminaire Family Tree and Dimensions
Explosionproof, Dust-Ignitionproof
Lighting
Ceiling
Four Hubs
Three Close-Up Plugs
3/4” NPT
CAC75
CAC75-1971
Lighting: Explosionproof — Visual Signal
Pendant
One Hub
—
3/4” NPT
CAP75
CAP75-1971
Bracket
Four Hubs
Three Close-Up Plugs
3/4” NPT
CALB75
CALB75-1971
Fixture Unit With Globe
Strobe
120AC
240AC
250DC
20-30DC
24DC
CSST120ACCL
CSST240ACCL
CSST250DCCL
CSST2030PDCCL ➊
CSST24PDCCL ➋
Optional Aluminum Guard
CJGU-15
Dimensions in Inches/Millimeters
Pendant
Ceiling
Wall Bracket
0.41"/
10.4 mm Dia.
Hub for .75"
NPT Conduit
4.00"/
101.6 mm
4.50"/
114.3 mm
4.00"/
101.6 mm
3.75"/
95.3 mm
4.50"/
114.3 mm
Dia.
5.92"/
150.4 mm
Hub for .75" NPT
Conduit Four Sides
13.15"/
334.0 mm
Hub For
2.46"/
62.5 mm
3/4” NPT 2” Wiring access
2.28"/
57.9 mm
cover both sides.
4.25"/
108.0 mm
4.92"/
125.0 mm Sq.
3.92"/
99.6 mm
1.23"/
31.2 mm
3.46"/
87.9 mm
1.79"/
45.5 mm
11.5"/
292.1 mm
13.75"/
349.3 mm
5.95"/
151.3 mm
13.88"/
352.6 mm
4.00"/
101.6 mm
4.92"/
125.0 mm
13.53"/
343.7 mm
12.38"/
314.5 mm
13.00"/
13.38"/ 330.2 mm
339.9 mm
13.75"/
349.3 mm
7.80"/
198.1 mm
7.80"/
198.1 mm
7.80"/
198.1 mm
➊ UL1971: Hearing-Impaired Strobe Only
➋ Diode polarized (current limiter supplied as standard).
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
1313
TCH Series Safety Flashlights
Increased Safety
Zone 1 & 2 - 21 & 22
II 2 GD
ATEX / IEC
IP66 (TCH1) IP66/68 (TCH2)
Lighting: Explosionproof — Portable
Lighting
Applications
• To provide maintenance staff with task specific portable
lighting in Zone 1 hazardous areas.
• Ideal for persons requiring task specific portable lighting
in refineries, oil and gas process and chemical plants.
Features
• Type TCH1:
— Luminescent switch facilitates locating flashlight in dark.
— Can be used to transmit a Morse code.
— Halogen version provides twice the lumen output of
incandescent lamps.
— Hook for hands free operation.
— Uses R20 or LR20 batteries (not included).
— Supplied with 1 lamp.
• Type TCH2:
— Dual optics (one at the end and one on the side) permitting:
- Focused beam for safe movement.
- Wide angle side beam for task specific focused lighting.
— Ergonomic design permits easy manipulation:
User can select one of the two beams with one hand.
— Two beams can be switched on separately and not
simultaneously.
— Should one lamp fail, the second lamp will still provide
illumination.
— Flashlight is stable when placed upright on a horizontal
surface.
— Pocket clip allows for hands free work.
— Luminescent ring allows easy locating of flashlight in dark.
— Suspension hook for hands free use.
— Uses 2 R20 or LR20 batteries (not included).
— Supplied with one halogen lamp for main beam and one
incandescent lamp for side beam.
— Supplied with one special opening tool.
Standard Material
• Type TCH1:
— Housing: shockproof and antistatic polyamide
— Internal reflector: polished
— Lens: polycarbonate
— Hardware: stainless steel
— Switch: luminescent
• Type TCH2:
— Housing: black polycarbonate
— Internal reflector: polished
— Lens: polycarbonate
— Hardware: stainless steel
— Ring: luminescent
Certifications and Compliances
•
Gas: Zones 1–2
— Conforming to ATEX 94/9/CE: CE 0081
II 2 G
— ATEX/IEC Protection: Ex eib IIC
— Certification Type TCH1
- T Rating: T4
- Ambient Temperature: -4 °C/20 °C ≤ To ≤ + 104°F/40 °C
- CE Declaration of Conformity: 50259
- ATEX Certificate: LCIE 03 ATEX 6064
- IEC Certificate: LCIE Ex 03.010
- Ingress Protection (solid and liquid): IP66
1314
TCH1
TCH2
— Certification Type TCH2
- T Rating:
-4 °F/20 °C ≤ To ≤ + 104 °F/40 °C: Incandescent PR6,
Krypton PR102, Halogen HPR52, Halogen HPR01 = T4
+104 °F/40 °C ≤ To ≤ + 131 °F/55 °C: Incandescent PR6,
Krypton PR102, Halogen HPR01 = T4
+104 °F/40 °C ≤ To ≤ + 131 °F/55 °C: Halogen HPR52 =
T3
Ambient Temperature: -4° F/-20 °C ≤ To ≤ + 131 °F/55 °C
- CE Declaration of Conformity: 50238
- ATEX Certificate: LCIE 02 ATEX 6229
- IEC Certificate: LCIE Ex 02.024
- Ingress Protection (solid and liquid): IP66/68 (25m)
• Dust: Zone 21-22
II2 D
— Conforming to ATEX 94/9/CE: CE 0081
— ATEX/IEC Protection: Ex tD A21
— Certification Type TCH1
- Surface Temperature: 203°F/95 °C
- Ambient Temperature: -4°F/-20 °C ≤ To ≤ + 104°F/40 °C
- CE Declaration of Conformity: 50259
- ATEX Certificate: LCIE 03 ATEX 6064
- IEC Certificate: LCIE Ex 03.010
- Ingress Protection (solid and liquid): IP66
— Certification Type TCH2
- Surface Temperature: 266° F/130 °C
Ambient Temperature: -4 °F/-20 °C ≤ To ≤ + 131 °F/55 °C
- CE Declaration of Conformity: 50238
- ATEX Certificate: LCIE 02 ATEX 6229
- IEC Certificate: LCIE Ex 02.024
- Ingress Protection (solid and liquid): IP66/68 (25m)
• Ex Standards: EN/IEC 60079-0; 60079-7; 60079-11; 61241-0;
61241-1
• Product Standards: EN/IEC 60598-1
• Other Standards: EN/IEC 60529 (IP)
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
TCH Series Safety Flashlights
Increased Safety
Zone 1 & 2 - 21 & 22
II 2 GD
ATEX / IEC
IP66 (TCH1) IP66/68 (TCH2)
Ordering Information:
Number of
Battery Cells
Weight
lbs/kgs
Volume
in3/dm3
1
Incandescent
2.5 V – 0.3 A
2
0.88/0.4
207.6/3.4
1
Incandescent
3.7 V – 0.3 A
3
0.88/0.4
207.6/3.4
1
Halogen
2.8 V – 0.5 A
2
0.88/0.4
207.6/3.4
2
0.88/0.4
116.0/1.9
2
Incandescent
2.5 V – 0.3 A
Halogen
2.8 V – 0.5 A
Catalog
Number
Pack
TCH12C
2
TCH13C
2
TCH12H
2
TCH22M
1
Lighting: Explosionproof — Portable
Type of Lamps
(not included)
Lighting
Number of
lamps
(included)
Spare Lamps for Replacement (Lamp Holder P13,5S)
Rating
Catalog Number
Pack
Incandescent (PR6)
Type of lamp
2.5 V – 0.3 A
TCHL25C
10
Incandescent (PR6)
3.7 V – 0.3 A
TCHL37C
10
Halogen (HPR01)
2.8 V – 0.5 A
TCHL28H
10
Dimensions in Inches/Millimeters
1.1/28.0
28
48
1.4/35.0
35
TCH13C
27
Ø2.8/72.0
72
44
Ø2.8/70.0
70
60
TCH12C/H
213
8.4/213.0
244
9.6/244.0
Ø2.4/60.0
Ø2.4/60.0
60
182
7.2/182.0
44
Ø1.7/44.0
TCH22M
Photometric Data
Catalog Number TCH12C (at 25 meters) Incandescent
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
Catalog Number TCH13C (at 25 meters) Incandescent
1315
AHL and EHL Incandescent Factory Sealed Luminaires and Handlamps
Explosionproof
Suitable for use in Wet Locations.
AHL
Class I, Division 1 and 2, Groups C, D
Class II, Division 1 and 2, Groups F ➊, G
Class III
EHL
Class I, Division 1 and 2, Groups C, D
Lighting
Applications
• AHL general purpose explosionproof lighting fixture – an
A-51 fixture with handle assembly of hook and cable clamp.
CAUTION: For safe operation, the AHL fixture weight must be
supported by the hanger hook, not by the flexible cord, per the
National Electrical Code.
• EHL general purpose explosionproof portable handlamp. Only
5”/127 mm in diameter for ease of movement.
Lighting: Explosionproof — Portable
Features:
• AHL and EHL
– Equipped with connection block for ease of wiring
and relamping.
– Cable clamp diameters: AHL – .375” to .625”/9.5 mm to 15.9
mm; EHL – .406”/10.3 mm for 16-3 AWG.
– Heat- and impact-resistant glass globes.
• AHL
– Sturdy fixture with rugged hanging hook.
– Safety grounding – additional terminal furnished to connect to
grounding conductor.
• EHL
– Portability, with phenolic handle and non-sparking guard
with hook.
– Easy relamping – loosen setscrew, unscrew guard, remove
globe and insert lamp.
– Safety grounding – remove cable and clamp and make
connections to terminal (including one ground terminal) then
tighten clamp.
AHL
EHL
Standard Materials
•
•
•
•
•
•
•
Globes: heat-and impact-resistant glass
AHL fixture unit, hook and guard: copperfree aluminum
AHL cable clamp: brass
EHL fixture body and handle: laminated phenolic
EHL handle: laminated phenolic
EHL hook: brass
EHL guard: copperfree aluminum
Standard Finishes
• AHL fixture unit, guard, handle and hook: two-coat
epoxy enamel
• AHL cable clamp: natural finish
• EHL fixture body: laminated phenolic
• EHL handle: phenolic
• EHL guard and hook: guard – natural finish; hook – zinc
electroplate and clear chromate
• EHL cable clamp: laminated phenolic
Certifications and Compliances
• UL Standard: UL 1598, UL 844
• EHL UL Listed: E59147
• CSA Certification: LR25428
Related Products
• The EHL handlamp may be used with AE Automatic TakeUp Reelites listed in the Specialty Products section and ECC
Cord Connector and Plugs and Receptacles in the Plug and
Receptacles section.
➊ To reduce the risk of ignition of hazardous atmospheres, do not use where electrically conductive dusts are present (most coal dusts are not electrically
conductive).
1316
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
AHL and EHL Incandescent Factory Sealed Luminaires and Handlamps
Explosionproof
Suitable for use in Wet Locations.
AHL
Class I, Division 1 and 2, Groups C, D
Class II, Division 1 and 2, Groups F ➊, G
Class III
EHL
Class I, Division 1 and 2, Groups C, D
Cable Diameter
(Inches)
Description
“T”
Ratings
Catalog
Number
AHL – Explosionproof 60 - 300 W Lighting Fixtures
60-100 W, A-21 (AAU-1N)
.375 to .625
T4
AHL100
200-300 W, PS-30 (AAU-2NS)
.375 to .625
T4A
AHL200
Laminated Phenolic Handle. Wiring Connection Block takes from #16 to #14 Wire.
100 W, A-21
.406
T3A
EHL100N
EHL Replacement Globe and Guard
Heat-resistant glass globe
XP419
Aluminum guard with hook
XP163SA
Dimensions in Inches/Millimeters
AHL
EHL
6.50"/
165.1 mm
7.50"/
190.5 mm
3.31"/84.1 mm
17.63"/447.8 mm
A
C
4.88"/124.0 mm
Dia.
B
Catalog Number
A
B
C
AHL100
14.25/362.0
7.06/179.3
10.94/277.9
AHL200
15.94/404.9
8.81/223.8
12.63/320.8
➊ To reduce the risk of ignition of hazardous atmospheres, do not use where electrically conductive dusts are present (most coal dusts are not electrically
conductive).
➋ Handlamp accommodates 16-3 SO cable. Contact your sales representative if 14-3 cable is required.
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
1317
Lighting: Explosionproof — Portable
EHL – Explosionproof 100 W Portable Handlamp ➋
Lighting
CAUTION: For safe operation, weight of fixture must be supported by hanger hook, not by the flexible cord, per the National Electrical Code.
Code•Master 2™ Emergency PLT Factory Sealed Luminaires
Explosionproof, Dust-Ignitionproof
52 W, 64 W, 84 W Fluorescent. For Use with Threaded Metal Conduit.
Class I, Division 1 and 2, Groups C, D
Class II, Division 1 and 2, Groups E, F, G
Class III
NEMA 4X
Marine Type Electric Fixtures
Outside Type (Salt Water)
Suitable for use in Wet Locations
NFPA101, Life Safety Code
Applications
• Ideal for use in chemical and petrochemical plants, such as
manufacturers of plastics, paints and thinners; in refineries; and
in other process areas where ignitable vapors, dust, moisture
and corrosive elements may be present.
• Suitable for use in wet locations.
Lighting: Explosionproof — Emergency
Lighting
Features
• Auxiliary (emergency) lighting should be used to provide a
lighted means of egress for personnel in walkways, catwalks,
stairs, doorways, tunnels, ramps and aisles.
• Auxiliary (emergency) lighting should be used to provide “instant
on” illumination during power failures.
• Arrangement of heat-producing components results in more
efficient heat dissipation for cooler fixture operation.
• Safe, easy servicing without disconnecting any wiring. Patented
“wireless” design means the threading of the fixture unit onto
mounting hood makes electrical connection. This allows for the
fixture unit to easily thread off mounting hood for convenient
servicing or for immediate replacement with a “stand-by” unit.
Only wiring required is attaching two wires to connection block
in mounting hood.
• Connection block is easily wired: (a) loosen two screws; (b)
make wire connections; and (c) reposition connection block.
• Acme double-lead threads speed installation and fixture
removal from mounting hood – only half as many turns are
required as for single-lead threads. The threads do not stick or
gall, eliminating the troublesome problems often encountered
with single-lead threads during fixture unit removal.
• All threaded joints are flame-tight.
• Factory sealed. External seals not required.
• Fluorescent light source reduces energy costs.
• Fluorescent lamp life of 10,000 hours reduces relamping costs
compared to incandescent.
• Strategic location of lamp sockets in combination with the
interior prism design of the glass globe provides optimum light
distribution and control.
• Superior corrosion resistance with epoxy powder coat finish.
• Choice of mountings: pendant, ceiling, bracket and stanchion.
• Fiberglass-reinforced polyester reflectors in standard
dome, deep dome or 30° angle are ideal in installations
where luminaire is subject to exceptionally severe corrosive
atmospheres. The high bay aluminum reflector is designed for
installations where mounting height work planes range from
20 to 30 feet/6 to 9 meters.
• Optional guards protect globes from damage. Guards secure to
fixture with three screws.
• Fixture (52, 64 or 84 W) is available for semi-continuous
operation (one AC ballast permits two-lamp illumination when
power is on and one battery pack permits one-lamp illumination
when AC power is interrupted).
• Minimum operating temperature: 32 °F/0 °C.
• Maximum operating temperature: 104 °F/ 40 ° C
Battery Pack Information
• Long life, high temperature, nickel-cadmium (Ni-Cad) battery.
• Dual voltage (120/277 V, 60 Hz) solid state charger on open
circuit board.
• Five-year life expectancy.
• Wiring instructions for “Push-To-Test” button are supplied
with fixture.
1318
Illustrated Features
• Remote “Push-To-Test” switch is available to verify emergency
operation (order separately, see F3-82).
• Red indicator light is provided with each battery pack to
indicate when the battery is charging.
Standard Materials
• Ballast bodies, guards and pendant mounting hoods:
copperfree (4/10 of 1% max.) aluminum
• Ceiling, bracket and stanchion mounting hoods: sand-cast
copperfree (4/10 of 1% max.) aluminum
• Reflectors: aluminum or fiberglass reinforced polyester
Standard Finishes
• Ballast bodies, guards and mounting hoods: epoxy powder
coat finish, electrostatically applied for complete, uniform
corrosion protection
Options
• Fuse kit CF2 for field installation.
Certifications and Compliances
• UL Standard: UL 924, UL 844, UL 1598
• UL Listed: E165014
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
Code•Master 2™ Emergency PLT Factory Sealed Luminaire Technical Data
Explosionproof, Dust-Ignitionproof
52 W, 64 W, 84 W Fluorescent. For Use with Threaded Metal Conduit.
Class I, Division 1 and 2, Groups C, D
Class II, Division 1 and 2, Groups E, F, G
Class III
NEMA 4X
Marine Type Electric Fixtures
Outside Type (Salt Water)
Suitable for use in Wet Locations
NFPA101, Life Safety Code
Classified Area Suitability of Code•Master 2 Emergency Series (Suitability includes use of reflector.)
Lamp
Type
Class I, Division 1 & 2
With Globe or with Globe & Reflector
UL/NEC Temp. Ident. No.
Nameplate
Marking
Groups
Class II, Division 1 & 2
With Globe or with Globe & Reflector
UL/NEC Temp. Ident. No.
Nameplate
Marking
Groups
Lamps
Watts
Ambient
Temp ˚
°F/°C
52
104/40
T6
C,D
T4
E,F,G
64
104/40
T6
C,D
T4
E,F,G
84
104/40
T6
C,D
T4
E,F,G
PLT
“T”
Number
350
325
T2
T2A
T2B
T2C
T2D
T3
T3A
T3B
T3C
T4
T4A
T5
Temp.
664Range 842
(°F)
619662
574617
538572
502536
448500
421446
394419
358392
331356
322329
277320
250275
214248
187212
185
Temp.
Range
(°˚C)
326350
301325
281300
261280
231260
216230
201215
181200
166180
161165
136160
121135
101120
86100
85
351450
T6
Fixture and Accessory Weights in Lbs/kg
Fixture Size
Fixture Weight
Reflector Weight
Guard Weight
52 W
45/20.4
3/1.4
2/0.9
64 W
45/20.4
3/1.4
2/0.9
84 W
45/20.4
3/1.4
2/0.9
Pendant
Ceiling
Bracket
Stanchion
2/0.9
4/1.8
6/2.7
2/0.9
Mounting Hood Weights Lbs/kg
Electrical Specification for AC Operation
Catalog
Number ➊
Fixture
Wattage
Line
Voltage (V)
Frequency
(Hz)
Type of
Ballast
Line
Amps (A)
Maximum Wattage
(W/W)
CMBFS5212
52
120
60
PLT Electronic
0.49
52
CMBFS5227
52
277
60
PLT Electronic
0.20
52
CMBFS6412
64
120
60
PLT Electronic
0.57
64
CMBFS6427
64
277
60
PLT Electronic
0.24
64
CMBFS8412
84
120
60
PLT Electronic
0.73
84
CMBFS8427
84
277
60
PLT Electronic
0.31
84
➊ For optional fusing. order kit -CF2
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
1319
Lighting: Explosionproof — Emergency
T1
Lighting
“T” Numbers Represent the Maximum Surface Temperature for Class I, Division 1 Locations and
Maximum Surface Temperature Under Dust Blanket for Class II, Division 1 Locations.
Code•Master 2™ Emergency PLT Factory Sealed Luminaires
Explosionproof, Dust-Ignitionproof
52 W, 64 W, 84 W Fluorescent. For Use with Threaded Metal Conduit.
Class I, Division 1 and 2, Groups C, D
Class II, Division 1 and 2, Groups E, F, G
Class III
NEMA 4X
Marine Type Electric Fixtures
Outside Type (Salt Water)
Suitable for use in Wet Locations
NFPA101, Life Safety Code
Lamp Watts
Lamp Type
52
PLT
Hub Size (Inches)
Catalog Number ➋➌
3/4
CFPS5275
Pendant
64
PLT
84
PLT
52
PLT
1
CFPS5210
3/4
CFPS6475
1
CFPS6410
3/4
CFPS8475
1
CFPS8410
3/4
CFCS5275
Lighting: Explosionproof — Emergency
Lighting
Ceiling
1
CFCS5210
3/4
CFCS6475
1
CFCS6410
3/4
CFCS8475
1
CFCS8410
3/4
1
3/4
1
3/4
1
CFBS5275
CFBS5210
CFBS6475
CFBS6410
CFBS8475
CFBS8410
64
PLT
84
PLT
52
PLT
64
PLT
84
PLT
52
PLT
1-1/4 or 1-1/2 ➊
CFSS52150
64
PLT
1-1/4 or 1-1/2 ➊
CFSS64150
84
PLT
1-1/4 or 1-1/2 ➊
CFSS84150
Bracket
25° Stanchion
Fixture Units
Ballast body with globe. Indicate voltage desired by adding voltage suffix to Fixture Unit catalog number listed below.
Add Voltage Suffixes
120 V
277 V
Lamp Watts
Lamp Type
Unit Catalog Number
52
PLT
CMBFS52
12
27
64
PLT
CMBFS64
12
27
84
PLT
CMBFS84
12
27
➊ 1-1/2” tapped hub furnished with 1-1/2” to 1-1/4” reducer.
➋ To order fixture with guard, add suffix -G before adding voltage suffix.
➌ Add voltage suffix -12L for 120 V with lamp; or -27L for 277 V with lamp.
1320
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
Code•Master 2™ Emergency PLT Factory Sealed Luminaire Accessories
Explosionproof, Dust-Ignitionproof
52 W, 64 W, 84 W Fluorescent. For Use with Threaded Metal Conduit.
Mounting Hoods
Hub Size Inches
Catalog Number
Pendant
3/4
CAP-75
1
CAP-100
3/4
CAC-75
1
CAC-100
3/4
CALB-75
1
CALB-100
One Hub
Ceiling
Four hubs,
Three Close-Up Plugs
Four hubs,
Three Close-Up Plugs
One Hub
1-1/4 or 1-1/2 ➊
CAS-150
Mounting Adapter with Connection Block
Permits use of existing A-51 mounting hoods (AAC Ceiling or AALB
Bracket) with the new Code•Master 2 Fixture Unit. After removing existing
Fixture Unit and adapter, screw in the new CMAD-1 Adapter. Then thread
thenew Fixture Unit into the CMAD-1.
CMAD-1
➊ 1-1/2” tapped hub furnished with 1-1/2” to 1-1/4” reducer.
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
1321
Lighting: Explosionproof — Emergency
25° Stanchion
Lighting
Bracket
Code•Master 2™ Emergency PLT Factory Sealed Luminaire Accessories
Explosionproof, Dust-Ignitionproof
52 W, 64 W, 84 W Fluorescent. For Use with Threaded Metal Conduit.
Description
Catalog Number
Standard Dome
CMR-4ST
Deep Dome
CMR-4DD
30˚ Angle
CMR-4AN
Polyester Reflectors
Lighting
Aluminum High Bay Reflectors
CMR-4HB
Lighting: Explosionproof — Emergency
Prismatic Glass Globes
52, 64, 84 W PLT
CGL-400
52, 64, 84 W PLT
CGU4
Aluminum Guards
Connection Block — For Code•Master 2 PLT Fixtures
1322
52 W - 84 W
PLT32RS
52 W - 84 W
VPT-7
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
Code•Master 2™ Emergency PLT Factory Sealed Luminaire Accessories
Explosionproof, Dust-Ignitionproof
52 W, 64 W, 84 W Fluorescent. For Use with Threaded Metal Conduit.
Dimensions in Inches/Millimeters
Pendant
Ceiling
Bracket
0.41"/
10.4 mm Dia.
.390"/
9.9 mm
4.58"/
116.3 mm
Dia.
4.92"/
125.0 mm Sq.
4.00"/
101.6 mm
3.91"/99.3 mm
9.86"/
250.4 mm
9.5"/
241.3 mm
2.28"/
2.46"/
62.5 mm 57.9 mm
6.10"/
154.9 mm
4.25"/
108.0 mm
3.46"/
87.9 mm
1.23"/
31.2 mm
3.92"/
99.6 mm
4.00"/
101.6 mm
5.92"/
150.4 mm
25° Stanchion
1.79"/
45.5 mm
4.5"/
60.5 mm
Dia.
2.38"/
60.5 mm Dia.
11.5"/
292.1 mm
13.75"/
349.3 mm
.94"/
23.9 mm
Lighting
9.86"/
250.4 mm
9.86"/
250.4 mm
4.00"/
101.6 mm
Pendant
A
52-84 W
B
Ceiling
C
D
A
B
Bracket
C
D
A
B
25° Stanchion
C
D
A
B
24.50/ 23.50/ 12.00/ 20.36/ 24.36/ 23.36/ 12.00/ 20.36/ 24.61/ 23.61/ 17.50/ 20.36/ 22.20/ 21.20/
622.3 596.9 304.8 517.1 618.7 593.3 304.8 517.1 625.1 599.7 444.5 517.1 563.9 538.5
C
17.50/
444.5
Reflector Dimensions in Inches/Millimeters
Type Reflector
Standard Dome
Deep Dome
A
B
C
11.20/
284.5
5.90/
149.9
18.70/
475.0
10.56/
268.2
7.00/
177.8
Standard and Deep Dome
20.30/
515.6
30° Angle
High Bay
10.96"/
278.4 mm
10.56"/
268.2 mm
13.30"/
337.8 mm
9.75”/
347.7 mm
16.16"/
410.5 mm
20.80"/
528.3 mm
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
1323
Lighting: Explosionproof — Emergency
5.50"/
139.7 mm
Code•Master 2™ Emergency PLT Factory Sealed Luminaire Photometric Data
Explosionproof, Dust-Ignitionproof
52 W, 64 W, 84 W Fluorescent. For Use with Threaded Metal Conduit.
* Photometric data is based on a fixture
with two 32 W Compact Fluorescent PL-T
lamps (2,400 lumens each). For candlepower
values of fixtures with two 26 W PL-T lamps
(1,800 lumens each), multiply by 0.75. For
Candlepower values of fixtures with two 42 W
PL-T Lamps. (3,200 lumens each) multiply by
1.34.
Total Luminaire Efficiency = 79.8%
CIE Type - Semi-Direct
Plane
Spacing
Criteria
0-180
2.88
90-270
2.88
Diagonal
2.82
REPORT NUMBER: CMBF64G
64 W (two 32 W lamps) Fluorescent Fixture with Globe only *
Coefficients of Utilization - Zonal Cavity Method
Effective Floor Cavity Reflectance 0.20
% Ceiling Rcc
Lighting: Explosionproof — Emergency
Lighting
% Walls
Zone
0-10
10-20
20-30
30-40
40-50
50-60
60-70
70-80
80-90
90-100
100-110
Lumens
17.70
61.05
132.44
236.78
336.66
421.68
485.34
517.29
513.72
468.70
352.77
110-120
200.85
120-130
73.54
130-140
140-150
150-160
160-170
170-180
11.28
1.12
0.31
0.06
0.00
Maximum Candela = 493
Located at Horizontal Angle = 0, Vertical Angle = 70
#1 – Vertical Plane through Horizontal Angles (0-180)
(Through Max. Cd.)
#2 – Horizontal Cone through Vertical Angle (70)
(Through Max. Cd.)
CIE Type - Direct
Spacing
Criteria
0-180
1.62
90-270
1.62
Diagonal
1.74
Zone
0-30
0-40
0-60
0-90
110-120
0.00
0.00
0.00
0.00
0.00
0.00
0.00
1324
30
10
0
50
30
10
70
50
30
10
50
30
10
50
30
10
50
30
10
0
0
1
2
3
4
5
6
7
8
9
10
90
76
67
60
54
49
45
41
38
35
33
90
70
58
49
43
37
33
29
26
24
22
90
65
51
41
34
29
25
22
19
17
15
90
60
45
35
28
23
19
16
14
12
11
85
71
63
56
50
46
42
38
36
33
31
85
66
55
46
40
35
31
28
25
23
21
85
61
48
39
32
27
23
20
18
16
14
85
57
42
33
26
22
18
15
13
11
10
76
58
48
40
35
31
27
24
22
20
18
76
54
43
34
28
24
21
18
16
14
13
76
51
38
29
23
19
16
14
12
10
9
68
51
42
35
30
26
23
21
19
17
16
68
48
37
30
25
21
18
16
14
12
11
68
45
34
26
21
17
14
12
10
9
8
60
45
36
30
26
23
20
18
16
15
14
60
42
32
26
21
18
16
14
12
11
10
60
40
29
23
18
15
12
10
9
8
7
57
36
26
20
15
12
10
8
7
9
5
Lumens
211.19
447.97
1206.31
2722.64
% Lamp
4.4
9.3
25.1
56.7
% Fixture
5.5
11.7
31.5
71.1
Zone
90-120
90-130
90-150
90-180
0-180
Lumens
1022.32
1095.85
1108.26
1108.63
3831.28
% Lamp
21.3
22.8
23.1
23.1
79.8
% Fixture
26.7
28.6
28.6
28.9
100.0
Coefficients of Utilization - Zonal Cavity Method
Effective Floor Cavity Reflectance 0.20
% Ceiling Rcc
Lumens
73.25
220.57
368.60
505.61
603.19
638.42
497.24
226.17
57.98
1.64
0.00
120-130
130-140
140-150
150-160
160-170
170-180
50
70
REPORT NUMBER: CMBF64ST
64 W (two 32 W lamps) Fluorescent Fixture with Globe and
Standard Dome Reflector *
% Walls
Zone
0-10
10-20
20-30
30-40
40-50
50-60
60-70
70-80
80-90
90-100
100-110
70
Rw
Zonal Lumen Summary
Total Luminaire Efficiency = 66.5%
Plane
80
80
70
50
30
10
0
Rw
70
50
30
10
70
50
30
10
50
30
10
50
30
10
50
30
10
0
0
1
2
3
4
5
6
7
8
9
10
79
72
65
59
53
49
45
41
38
35
33
79
69
59
51
45
39
35
32
29
26
24
79
66
54
45
38
33
29
25
23
20
18
79
63
50
41
34
28
24
21
19
16
15
77
70
63
57
52
47
43
40
37
34
32
77
67
58
50
44
39
34
31
28
26
24
77
64
53
45
38
33
29
25
22
20
18
77
62
49
40
33
28
24
21
18
16
15
74
64
55
48
42
37
33
30
27
25
23
74
62
52
43
37
32
28
25
22
20
18
74
60
48
40
33
28
24
21
18
16
15
71
62
53
46
40
36
32
29
26
24
22
71
60
50
42
36
31
27
24
22
19
18
71
58
47
39
32
28
24
21
18
16
15
68
59
51
44
39
35
31
28
26
23
22
68
58
48
41
35
31
27
24
21
19
17
68
56
46
38
32
27
23
20
18
16
14
66
55
45
37
30
26
22
19
17
15
13
Zonal Lumen Summary
Maximum Candela = 808
Located at Horizontal Angle = 0, Vertical Angle = 35
#1 – Vertical Plane through Horizontal Angles (0-180)
(Through Max. Cd.)
#2 – Horizontal Cone through Vertical Angle (35)
(Through Max. Cd.)
Zone
0-30
0-40
0-60
0-90
Lumens
662.42
1168.03
2409.64
3191.04
% Lamp
13.8
24.3
50.2
66.5
% Fixture
20.7
36.6
75.5
99.9
Zone
Lumens
90-120
1.64
90-130
1.64
90-150
1.64
90-180
1.64
0-180 3192.68
% Lamp
0.0
0.0
0.0
0.0
66.5
% Fixture
0.1
0.1
0.1
0.1
100.0
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
Code•Master 2™ Emergency PLT Factory Sealed Luminaire Photometric Data
Explosionproof, Dust-Ignitionproof
52 W, 64 W, 84 W Fluorescent. For Use with Threaded Metal Conduit.
* Photometric data is based on a fixture
with two 32 W Compact Fluorescent PL-T
lamps (2,400 lumens each). For candlepower
values of fixtures with two 26 W PL-T lamps
(1,800 lumens each), multiply by 0.75. For
Candlepower values of fixtures with two 42 W
PL-T Lamps. (3,200 lumens each) multiply by
1.34.
Total Luminaire Efficiency = 57.4%
CIE Type - Direct
Plane
Spacing
Criteria
0-180
1.52
90-270
1.70
Diagonal
1.62
REPORT NUMBER: CMBF64AN
64 W (two 32 W lamps) Fluorescent Fixture with Globe and
30° Angle Dome Reflector *
Coefficients of Utilization - Zonal Cavity Method
Effective Floor Cavity Reflectance 0.20
% Ceiling Rcc
% Walls
Lumens
62.13
187.93
317.49
428.14
471.22
454.23
384.77
276.31
157.68
13.45
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
Maximum Candela = 731
Located at Horizontal Angle = 90, Vertical Angle = 37.5
#1 – Vertical Plane through Horizontal Angles (90-270)
(Through Max. Cd.)
#2 – Horizontal Cone through Vertical Angle (37.5)
(Through Max. Cd.)
CIE Type - Direct
Spacing
Criteria
0-180
1.44
90-270
1.44
Diagonal
1.60
Zone
0-30
0-40
0-60
0-90
110-120
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0
10
70
50
30
10
50
30
10
50
30
10
50
30
10
0
0
1
2
3
4
5
6
7
8
9
10
68
61
55
50
45
41
38
35
32
30
28
68
58
49
43
37
33
30
27
24
22
20
68
55
45
37
32
28
24
21
19
17
16
68
52
41
33
28
23
20
18
16
14
12
67
59
53
48
44
40
37
34
32
29
28
67
56
48
42
37
32
29
26
24
22
20
67
54
44
37
31
27
24
21
19
17
15
67
51
40
33
27
23
20
18
15
14
12
64
54
46
40
35
31
28
25
23
21
19
64
51
43
36
31
27
23
21
19
17
15
64
49
39
32
27
23
20
17
15
14
12
61
51
44
38
34
30
27
24
22
20
19
61
49
41
35
30
26
23
20
18
16
15
61
48
39
32
27
23
20
17
15
14
12
58
49
42
37
32
29
26
24
22
20
18
58
48
40
34
29
25
22
20
18
16
15
58
46
38
31
26
22
19
17
15
13
12
57
45
36
30
25
21
18
16
14
12
11
Lumens
567.55
995.69
1921.14
2739.90
% Lamp
11.8
20.7
40.0
57.1
% Fixture
20.6
36.2
69.8
99.5
Zone
90-120
90-130
90-150
90-180
0-180
Lumens
13.45
13.45
13.45
13.45
2753.35
% Lamp
0.3
0.3
0.3
0.3
57.4
% Fixture
0.5
0.5
0.5
0.5
100.0
Coefficients of Utilization - Zonal Cavity Method
Effective Floor Cavity Reflectance 0.20
% Ceiling Rcc
Lumens
88.95
260.61
413.34
539.82
630.36
641.74
436.60
164.84
47.37
1.92
0.00
120-130
130-140
140-150
150-160
160-170
170-180
10
30
REPORT NUMBER: CMBF64DD
64 W (two 32 W lamps) Fluorescent Fixture with Globe and
Deep Dome Reflector *
% Walls
Zone
0-10
10-20
20-30
30-40
40-50
50-60
60-70
70-80
80-90
90-100
100-110
30
50
Zonal Lumen Summary
Total Luminaire Efficiency = 67.2%
Plane
50
70
80
70
50
30
10
0
Rw
70
50
30
10
70
50
30
10
50
30
10
50
30
10
50
30
10
0
0
1
2
3
4
5
6
7
8
9
10
80
73
66
60
55
50
46
43
40
37
34
80
70
61
53
47
41
37
33
30
28
25
80
67
56
47
41
35
31
27
24
22
20
80
65
52
43
36
31
26
23
20
18
16
78
71
65
59
53
49
45
41
38
36
34
78
68
59
52
46
41
36
33
30
27
25
78
66
55
47
40
35
30
27
24
22
20
78
63
52
43
36
30
26
23
20
18
16
75
66
57
50
44
39
35
32
29
26
24
75
63
53
45
39
34
30
27
24
21
19
75
61
50
42
35
30
26
23
20
18
16
71
63
55
48
42
38
34
31
28
26
24
71
61
52
44
38
33
29
26
23
21
19
71
60
49
41
35
30
26
23
20
18
16
69
60
53
46
41
37
33
30
27
25
23
69
59
50
43
37
33
29
26
23
21
19
69
58
48
40
34
29
25
22
20
18
16
67
56
47
39
33
28
24
21
19
16
15
Zonal Lumen Summary
Maximum Candela = 933
Located at Horizontal Angle = 0, Vertical Angle = 7.5
#1 – Vertical Plane through Horizontal Angles (0-180)
(Through Max. Cd.)
#2 – Horizontal Cone through Vertical Angle (7.5)
(Through Max. Cd.)
Zone
0-30
0-40
0-60
0-90
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
Lumens
762.91
1302.73
2574.82
3223.63
% Lamp
15.9
27.1
53.6
67.2
% Fixture
23.7
40.4
79.8
99.9
Zone
90-120
90-130
90-150
90-180
0-180
Lumens
1.92
1.92
1.92
1.92
3225.55
% Lamp
0.0
0.0
0.0
0.0
57.4
% Fixture
0.1
0.1
0.1
0.1
100.0
1325
Lighting: Explosionproof — Emergency
110-120
120-130
130-140
140-150
150-160
160-170
170-180
70
Rw
Lighting
Zone
0-10
10-20
20-30
30-40
40-50
50-60
60-70
70-80
80-90
90-100
100-110
80
Code•Master 2™ Emergency PLT Factory Sealed Luminaire Photometric Data
Explosionproof, Dust-Ignitionproof
52 W, 64 W, 84 W Fluorescent. For Use with Threaded Metal Conduit.
* Photometric data is based on a fixture
with two 32 W Compact Fluorescent PL-T
lamps (2,400 lumens each). For candlepower
values of fixtures with two 26 W PL-T lamps
(1,800 lumens each), multiply by 0.75. For
Candlepower values of fixtures with two 42 W
PL-T Lamps. (3,200 lumens each) multiply by
1.34.
Total Luminaire Efficiency = 58.9%
REPORT NUMBER: CMBF64HB
64 W (two 32 W lamps) Fluorescent Fixture with Globe and High Bay Reflector *
CIE Type - Direct
Plane
Spacing
Criteria
0-180
0.82
Coefficients of Utilization - Zonal Cavity Method
90-270
0.82
Effective Floor Cavity Reflectance 0.20
Diagonal
0.92
Zone
Lumens
% Ceiling Rcc
Lighting: Explosionproof — Emergency
Lighting
% Walls
Rw
80
70
50
70
30
10
70
50
50
30
10
50
30
30
10
50
30
10
10
50
30
0
10
0
0 70 70 70 70 68 68 68 68 65 65 65 63 63 63 60 60 60 59
0-10
239.15
1 66 64 63 61 65 63 62 60 61 59 58 58 57 57 56 56 55 54
10-20
599.67
2 62 59 56 54 61 58 55 53 56 54 52 54 52 51 52 51 50 49
20-30
645.20
3 58 54 51 48 57 53 50 47 51 49 47 50 48 46 49 47 45 44
30-40
625.54
4 55 50 46 43 54 49 45 43 48 44 42 46 44 42 45 43 41 40
40-50
452.95
5 51 46 42 39 50 45 41 39 44 41 38 43 40 38 42 39 37 36
50-60
185.71
6 48 42 38 35 47 42 38 35 41 37 35 40 37 35 39 36 34 33
60-70
58.40
7 46 39 35 32 45 39 35 32 38 35 32 37 34 32 37 34 32 31
70-80
15.26
8 43 37 33 30 42 36 32 30 36 32 30 35 32 29 34 31 29 28
80-90
4.25
9 41 34 30 28 40 34 30 28 33 30 27 33 30 27 32 29 27 26
90-100
0.69
10 38 32 28 26 38 32 28 26 31 28 26 31 28 25 30 27 25 25
100-110
0.00
110-120
0.00
120-130
0.00
Zonal Lumen Summary
Zone
Lumens
% Lamp
% Fixture
Zone
Lumens
% Lamp
% Fixture
130-140
0.00
0-30
1484.03
30.9
52.5
90-120
0.69
0.0
0.0
140-150
0.00
0-40
2109.57
43.9
74.6
90-130
0.69
0.0
0.0
150-160
0.00
160-170
0.00
170-180
0.00
1326
Maximum Candela = 2540
Located at Horizontal Angle = 0, Vertical Angle = 5
#1 – Vertical Plane through Horizontal Angles (0-180)
(Through Max. Cd.)
#2 – Horizontal Cone through Vertical Angle (5)
(Through Max. Cd.)
0-60
2748.23
57.3
97.2
90-150
0.69
0.0
0.0
0-90
2826.12
58.9
100.0
90-180
0.69
0.0
0.0
2628.80
58.9
100.0
0-180
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
ELS Series Emergency Lighting System
Explosionproof, Dust-Ignitionproof
Remote and direct mounted fixtures for hazardous location applications
Class I, Division 1 and 2, Groups B*, C, D
Class II, Division 1 and 2, Groups E, F, G
Class III
Applications
• ELS Series features an emergency lighting power unit that is
designed to provide safe operation in the presence of hazardous
gases, vapors or dusts, defined by the National Electrical Code
as Class I, Groups C and D, and Class II, Groups E, F and G.
• Typical applications include all means of egress (such as
walkways, exit ramps, stairs and aisles) for hazardous areas
which include oil refineries, petrochemical facilities, pulp and
paper mills, chemical storage areas, wastewater treatment
facilities and grain elevators.
Features
Lighting
Lighting: Explosionproof — Emergency
• The electronics consist of a solid-state charger, transfer circuit
and low-voltage battery disconnect circuit.
• The unit test switch and AC “On” indicator light are housed in
a separate module that may be attached directly to the unit
housing or mounted remotely for ease of testing.
• All ELS Series units are rated for operation in NEC Class I,
Division 1 and 2, Groups C and D; and Class II, Division 1 and 2,
Groups E, F, and G environments.
• Housing provisions allow for the attachment of two optional
explosionproof lighting fixtures.
• Unit capacity is sufficient for the connection of up to four 6- or
12- volt, 18-watt fixtures.
• Units provide 90 minutes of emergency operation.
• The solid-state charger maintains battery at full charge.
• Upon failure of utility voltage, the DC emergency lighting load is
connected to the battery.
• During emergency operation, automatic battery protection from
deep discharge damage is provided by a low-voltage battery
disconnect (LVD) circuit.
• Upon restoration of normal power, the charger will begin a
recharge cycle. It will bring the battery to full capacity within
acceptable UL time standards.
• A pilot light indicates the presence of AC line voltage, and a test
switch is provided for checking transfer operation. Lock-out
type guard on push button accepts locks with up to 1/4”/6.5
mm hasp.
• A universal transformer allows operation on 120 or 277 Vac
lines.
• Emergency power source is a maintenance-free, sealed,
pure-lead battery suited for harsh temperature environments
for 32 °F to 104 °F/0 °C to 40 °C.
— Never necessary to add water.
— Expected life is 10 years
— Compact in design
• Standard illumination is provided during power failure only using
fixtures specially designed for emergency lighting in hazardous
environments, supplied with double contact bayonet base 18or 28-watt incandescent lamps.
• Designed for easy installation. Provided with 4 mounting holes
for attachment to a wall or other suitable surface. Mounting
hardware not included.
• Housing is drilled and tapped for installation of utility
1/2”/12.7 mm NPT conduit.
• Quick access to internal wiring and components is provided
by thread-on cover.
• All necessary fittings for test switch/ pilot light module
supplied standard.
Standard Materials
• Battery enclosure, fixtures, guards and pendant mount:
copperfree (4/10 of 1% max.) aluminum.
• Ceiling and bracket mounts: malleable iron with aluminum
adapter
• Reflectors: porcelain enameled steel
• Test Switch: copperfree (4/10 of 1% max.) aluminum with
stainless steel hardware
Standard Finishes
• Enclosure, fixtures and test station: epoxy powder coat
finish electrostatically applied for complete and uniform
surface protection
• Reflectors: white porcelain enamel
Options
• The fixture may be adapted to serve as an exit sign through use
of an Auxiliary Exit Housing.
• Time Delay Relay (15 minutes) available to permit normal
lighting to re-establish brightness. Add suffix -T1 for 120 Vac, or
-T2 for 277 Vac.
Certifications and Compliances
• UL Standard: UL 924, UL 844, UL 1598
• UL Listed: 175025
* Contact your sales representative for Class I, Group B rating.
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
1327
ELS Series Emergency Lighting System Technical Data
Explosionproof, Dust-Ignitionproof
Remote and direct mounted fixtures for hazardous location applications
Class I, Division 1 and 2, Groups B*, C, D
Class II, Division 1 and 2, Groups E, F, G
Class III
Order using catalog numbering guide below or select catalog number from tables on following pages.
Catalog Numbering Guide
ELS
2
18
Series:
6
T1G
Wattage per lamp
18 – 18 W
28 – 28 W
Options
T1 – Time delay relay, 120
Vac input
T2 – Time delay relay, 277
Vac input
G – Guard installed on
fixture
Lighting
Number of direct mounted fixtures
0 – no direct mounted fixtures
1 – 1 direct mounted fixture
2 – 2 direct mounted fixtures
Lamp Voltage
6 – 6 Vdc
12 – 12 Vdc
Lighting: Explosionproof — Emergency
Capacity of standard ELS unit (75 W for 90 minutes)
Up to 2 fixtures may be direct mounted. The remainder must be remote mounted.
Combination
Number
Number of
Fixtures
Wattage per
Fixture
Total
Wattage
1
1
18
18
2
1
28
28
3
2
18
36
4
2
28
56
5
3
18
54
6
1
28
64
6
2
18
64
7
4
18
72
Lamp
Watts
Supply Wire Temp
°F/°C
Ambient Temp
°F/°C
Class I, Division 1 & 2
Operating Temperature
Class II, Division 1 & 2 (Groups E, F & G)
Operating Temperature
18
257/125
104/40
T5
T3C
28
257/125
104/40
T5
T3C
“T” Numbers Represent the Maximum Surface Temperature for Class I, Division 1 Locations and
Maximum Surface Temperature Under Dust Blanket for Class II, Division 1 Locations.
NOTE: The maximum operating temperature of the fixture must not exceed the ignition temperature of the gas, vapor or dust to be encountered per the National
Electrical Code. Operating temperatures are with and without reflectors and guards.
“T”
Number
T1
350
325
T2
T2A
T2B
T2C
T2D
T3
T3A
T3B
T3C
T4
T4A
T5
T6
Temp
Range
(°F)
664842
619662
574617
538572
502536
448500
421446
394419
358392
331356
322329
277320
250275
214248
187212
185
Temp.
Range
(°C)
351450
326350
301325
281300
261280
231260
216230
201215
181200
166180
161165
136160
121135
101120
86100
85
* Contact your sales representative for Class I, Group B rating.
1328
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
ELS Series Emergency Lighting System
Explosionproof, Dust-Ignitionproof
Remote and direct mounted fixtures for hazardous location applications
Class I, Division 1 and 2, Groups C, D
Class II, Division 1 and 2, Groups E, F, G
Class III
Emergency Lighting System with Direct Mounted Fixtures
Catalog Number
(Lamp(s) Included)
Watts per Lamp
Lamp Voltage
Input Voltage
2
18
6 Vdc
120/277 Vac
ELS2186 ➊➋➌➍
2
28
6 Vdc
120/277 Vac
ELS2286 ➊➋➌➍
2
18
12 Vdc
120/277 Vac
ELS21812 ➊➋➌➍
2
28
12 Vdc
120/277 Vac
ELS22812 ➊➋➌➍
1
18
6 Vdc
120/277 Vac
ELS1186 ➋➌➍
1
28
6 Vdc
120/277 Vac
ELS1286 ➊➋➌➍
1
18
12 Vdc
120/277 Vac
ELS11812 ➊➋➌➍
1
28
12 Vdc
120/277 Vac
ELS12812 ➊➋➌➍
Lamp Voltage
Input Voltage
Catalog Number
with Push-to-Test
(Incl. Fittings)
6 Vdc
120/277 Vac
ELS06 ➊➋➌
12 Vdc
120/277 Vac
ELS012 ➊➋➌
Lighting
Number of Fixtures
Emergency Lighting System Enclosure with Battery and Charger
Watts Per
Lamp
Lamp
Voltage
Catalog Number
(Lamp Included)
18
6 Vdc
AP1050-186-DM ➍
28
6 Vdc
AP1050-286-DM ➍
18
12 Vdc
AP1050-1812-DM ➍
28
12 Vdc
AP1050-2812-DM ➍
➊ 1/2” NPT provided for AC input.
➋ Add suffix T1 for time delay relay for 120 Vac input.
➌ Add suffix T2 for time delay relay for 277 Vac input.
➍ To order fixtures with guard installed add suffix G. Reflectors and exit signs are ordered separately. See Accessories page.
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
1329
Lighting: Explosionproof — Emergency
Emergency Lighting System Fixture for Direct Mounting to Enclosure Includes all necessary fittings and lamp.
ELS Series Emergency Lighting System
Explosionproof, Dust-Ignitionproof
Remote and direct mounted fixtures for hazardous location applications
Class I, Division 1 and 2, Groups C, D
Class II, Division 1 and 2, Groups E, F, G
Class III
Emergency Lighting System Fixture for Remote Mounting — Lamp Included — Shown with Optional Guard
Mounting
Type
Watts Per
Lamp
Lamp
Voltage
Catalog Number
(Lamp Included) ➊
18
6 Vdc
AP1050-186
28
6 Vdc
AP1050-286
18
12 Vdc
AP1050-1812
28
12 Vdc
AP1050-2812
18
6 Vdc
AC1050-186
28
6 Vdc
AC1050-286
18
12 Vdc
AC1050-1812
28
12 Vdc
AC1050-2812
18
6 Vdc
ALB1050-186
28
6 Vdc
ALB1050-286
18
12 Vdc
ALB1050-1812
28
12 Vdc
ALB1050-2812
18
6 Vdc
ASB1050-186
28
6 Vdc
ASB1050-286
18
12 Vdc
ASB1050-1812
28
12 Vdc
ASB1050-2812
Pendant — One 1/2” Hub
Lighting: Explosionproof — Emergency
Lighting
Ceiling — Four 1/2” Hubs, Three Close-Up Plugs
Long Bracket — Four 1/2” Hubs, Three Close-Up Plugs
Short Bracket — 15 degrees — Two 1/2” Hubs, One Close-Up Plug
Emergency Lighting System Replacement Fixtures — Lamp included — Fits existing mounting hood
Watts Per
Lamp
Lamp
Voltage
Catalog Number
(Lamp Included) ➊
18
6 Vdc
AAU1N-186
28
6 Vdc
AAU1N-286
18
12 Vdc
AAU1N-1812
28
12 Vdc
AAU1N-2812
➊ To order fixtures with guard installed, add suffix G. Reflectors and exit signs are ordered separately. See Accessories page.
1330
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
ELS Series Emergency Lighting System Accessories
Explosionproof, Dust-Ignitionproof
Remote and direct mounted fixtures for hazardous location applications
Description
Catalog Number
Guard
AAGU1
Three-Way Exit Sign
CJEXRN
Epoxy enameled steel — 6”-high red lettering
Mounts to fixture units in place of guard.
AEXR-15R
Lighting
Epoxy enameled steel — 6”-high red lettering
Mounts to fixture units in place of guard.
Single-Sided Exit Sign
Lighting: Explosionproof — Emergency
30° Angle Reflector
AARW15AN
Standard Dome Reflector
AARW15ST
Push-to-Test Station
Complete Push-to-Test Station
EFDCB150J1U1-T-A
Cover with Switch and Pilot Light
EFKB-J1U1-TEST
Switch Only
SPBB-U1-Q
Pilot Light Only
SPLNS-RE-B
Lamp, 18 W, 6 Vdc
59620527074
Lamp, 28 W, 6 Vdc
59620527075
Lamp, 18 W, 12 Vdc
59620527076
Lamp, 28 W, 12 Vdc
59620527078
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
1331
ELS Series Emergency Lighting System Weights and Dimensions
Explosionproof, Dust-Ignitionproof
Remote and direct mounted fixtures for hazardous location applications
Weight lbs/kg
Catalog Number
Weight lbs/kgs
Catalog Number
52.0/23.6
11.0/5.0
9.0/4.1
12.5/5.7
16.6/7.5
12.5/5.7
4.0/1.8
ELS06, ELS012
AP1050-186-DM
AP1050-186
AC1050-186
ALB1050-186
ASB1050-186
EFDCB150J1U1-T-A
7.6/3.4
0.4/0.2
5.0/2.3
5.0/2.3
2.1/1.0
2.1/1.0
AAU1N-186
AAGU1
AEXR-15R
CJEXRN
AARW15AN
AARW15ST
Dimensions in Inches/Millimeters
Lighting
14.69"/
373.1 mm
13.50"/342.9 mm
14.38"/365.3 mm
11.63"/
295.4 mm
10.75"/
273.1 mm
12.00"/
304.8 mm
14.12"/
358.6 mm
12.25"/
311.2 mm
12.25"/
311.2 mm
Lighting: Explosionproof — Emergency
13.13"/333.5 mm
7.06"/
179.3 mm
Battery Enclosure
Direct Mount fixture
4.75"/120.7 mm
5.38"/
136.7 mm
Pendant Mount
2.63"/66.8 mm
2.69"/68.3 mm
13.13"/
333.5 mm
12.94"/
328.7 mm
.38"/9.7 mm
3.38"/
85.9 mm
.38"/9.7 mm
1.31"/
33.8 mm
45°
13.56"/
344.4 mm
13.75"/
349.3 mm
13.13"/
333.5 mm
13.75"/
349.3 mm
9.13"/
231.9 mm
12.38"/
314.5 mm
7.06"/
179.3 mm
Ceiling Mount
Long Bracket Mount
Short Bracket Mount
3.00"/
76.2 mm
6.88"/
174.8 mm
5.41"/
137.4 mm
11.75"/298.5 mm
"/
.00 m
104.0 m
25
8.50"/
215.9 mm
EFDCB150J1JU1-T-A
AEXR-15R
33.50"/850.9 mm
7.63"/
193.8 mm
AARW15AN
13.00"/330.2 mm
9.25"/
235.0 mm
4.38"/
111.3 mm
28.67"/
728.2 mm
ELS with 2 direct mounted fixtures
1332
12.00"/
304.8 mm
CJEXRN
14.00"/355.6 mm
AARW15ST
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
HBE Series Round Bulkhead Luminaires
Increased Safety
Zone 1 & 2 - 21 & 22
II 2 GD
ATEX / IEC
IP65
Applications
•
Suitable for use in:
— Stairways
— Small areas
— Emergency exit
Features
• For incandescent lamps 60 W to 150 W maximum, mixed lamp
100 W maximum. Lamps not supplied.
• E27 lampholder.
• Screw locking mechanism.
• Operates in all positions.
• Connection to lampholder via two 0.003 x 0.004 in2 /
2 x 2.5 mm2 terminals.
• Internal earth two terminals 0.003 x 0.004 in2 / 2 x 2.5 mm2.
External earth 0.002 x 0.006 in2 / 1 x 4 mm2.
• Three M20 entries in “T” formation. Supplied with one M20
cable gland (dia. 0.26 to 0.57 in / 6.5 to 14.5 mm) and two M20
blanking plugs.
Standard Materials
•
•
•
•
•
HBERI15 and HBEPGZ
Body: gray painted aluminum alloy
Diffuser: glass
Sealing gasket: silicone
Guard: zinc plated steel
Cable gland and blanking plug: polyamide
Certifications and Compliances
Certification Type HBe150
Gas, Zones 1 and 2
— Conforming to ATEX 94/9/CE: CE 0081 II 2 G
— ATEX/IEC Protection: Ex e II
— T Rating: See Table
Dust, Zones 21 and 22
— Conforming to ATEX 94/9/CE: CE 0081 II2 D
— ATEX/IEC Protection: Ex tD A21
— Surface Temperature: T216 °F/T102 °C to T279 °F/T137 °C
Ambient Temperature: -40 °F/-40 °C to 122 °F/+50 °C
CE Declaration of Conformity: 50244
ATEX Certificate: LCIE 02 ATEX 6228X
IEC Certificate: LCIE Ex 02.023X
Index of Protection (solid & liquid): IP65
Ex Standards: EN / IEC 60079-0; 60079-7; 61241-0; 61241-1
Product Standards: EN / IEC 60598-1
Other Standards: EN / IEC 60529 (IP)
Lighting: Increased Safety/Flameproof — Bulkhead
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
Lighting
•
•
•
•
•
•
•
•
•
•
•
1333
HBE Series Round Bulkhead Luminaires
Increased Safety
Zone 1 & 2 - 21 & 22
II 2 GD
ATEX / IEC
IP65
Weight
(lbs/kg)
Volume
(in3/dm3)
Pack
Catalog Number
6.61/3
915.36/15
1
HBERI15
Pack
Catalog Number
Protective Guard
1
HBEPGZ
Spare lampglass
1
HBEGD
Accessories
T-Rating for Dust and Gas
Power and Type
Watts
Type
Dust
Operating
Positions
Surface T° for
Ta = 122° F/50° C
Gas
For Ta = 104° F/40° C
T° at
T Rating
Cable Entry
Lighting
Any Position
60
Incandescent
216°F/102°C
Any Position
Lighting: Increased Safety/Flameproof — Bulkhead
75
Incandescent
225°F/107°C
Any Position
100
Mercury
243°F/117°C
Any Position
100
Incandescent
279°F/137°C
Any Position
150
Mixed
266°F/130°C
122° F/50° C
T Rating
T° at
Cable Entry
T2
T2
T3
T3
T4
T4
T2
T2
T3
T3
T4
T4
T2
T2
181°F/83°C
T3
T3
181°F/83°C
T3
T3
T1
194°F/90°C
T1
212°F/100°C
T3
194°F/90°C
T2
212°F/100°C
T3
T3
T2
180°F/82°C
T2
92°C
T3
180°F/82°C
T3
92°C
T3
T3
Not Applicable, no need for high temperature cable for cable entry temperature less than +176 ºF/+80 ºC
1334
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
HBE Series Round Bulkhead Luminaires
Increased Safety
Dimensions in Inches/Millimeters
6.81"/
173 mm
6.14"/
156 mm
Cable entries
11.65"/
296 mm
Ø0.23"/
6 mm
6.30"/
160 mm
Protective guard
Photometric Data ➊
Lighting
150 W Incandescent
NF C 71-120: .062 J + 0.10 T
Candela
Distribution
Degrees
0
94
5
95
97
15
104
20
104
30
105
40
86
50
85
60
77
70
113
80
115
90
108
100
32
90°
80°
70°
Lighting: Increased Safety/Flameproof — Bulkhead
10
100°
60°
50°
40°
30°
0°
15°
20°
➊ Polar curves for a 1000 lm flux, according to NF C 71-120 Luminaire symbol according to NF C 71-121.
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
1335
HBD Series Bulkhead Luminaires
Flameproof
Zone 1, 2, 21 & 22
II 2 GD
ATEX / IEC
IP66 - IK08
Applications
•
Suitable for use in:
— Stairways
— Small areas
— Emergency exit
Lighting
Features
• HBDR
— Lamps (not supplied)
— Incandescent 200 W maximum
— Compact Fluorescent 23 W maximum
— Mixed 160 W maximum
— Threaded flameproof joint.
— Operates on ceiling and wall.
• HBRO
— Incandescent 60 W to 100 W maximum
— Compact fl uorescent 15 W maximum
— Operates in any position.
— For incandescent 60 W & 100 W a high temperature cable
223 °F/106 °C is required.
• Lamps are not supplied.
• E27 lampholder.
• Fixing by two integrated brackets.
• Connection to lampholder via two terminals 0.004 in2 / 2.5 mm2.
• Internal earth two terminals 0.004 in2 / 2.5 mm2.
• External earth one 0.006 in2 / 4 mm2.
• 3 x M20 threaded entries in “T” formation.
• Supplied with two blanking plugs M20.
HBDR
Round Bulkhead
Standard Materials
• Body and bezel: gray painted aluminum
• Glass: sealed toughened lamp glass
• Protective guard: zinc plated steel
Lighting: Increased Safety/Flameproof — Bulkhead
Certifications and Compliances
• HBRD
— Certification Type HBRd
— Gas, Zones 1 and 2
– Conforming to ATEX 94/9/CE: CE 0081
II 2 G
– ATEX/IEC Protection: Ex d IIC
– T Rating: See Table
— Dust, Zones 21 and 22
– Conforming to ATEX 94/9/CE: CE 0081
II 2 D
– ATEX/IEC Protection: Ex tD A21
— Ambient Temperature: -40 °F/-40 °C to 131 °F/55 °C
— CE Declaration of Conformity: 50242
— ATEX Certificate: LCIE 02 ATEX 6163
— IEC Certificate: LCIE Ex 02.014
• HBRO
— Certification Type HBOd
— Gas, Zones 1 and 2
– Conforming to ATEX 94/9/CE: CE 0081
II 2 G
– ATEX/IEC Protection: Ex d IIB
– T Rating: See Table
— Dust, Zones 21 and 22
– Conforming to ATEX 94/9/CE: CE 0081
II 2 D
– ATEX/IEC Protection: Ex tD A21
— Ambient Temperature: -4 °F/-20 °C to 104 °F/40 °C
— CE Declaration of Conformity: 50232
— ATEX Certificate: LCIE 02 ATEX 6162
— IEC Certificate: LCIE Ex 02.013
1336
HBDO
Oval Bulkhead
•
•
•
•
•
•
•
Other Certifications: GOST
Index of Protection (solid & liquid): IP66
Impact Resistance (shock): IK08
Internal Volume: > 122.05 in3/ 2 dm3 (2 liters)
Ex Standards: EN / IEC 60079-0; 60079-1; 61241-0; 61241-1
Product Standards: EN / IEC 60598-1
Other Standards: EN / IEC 60529 (IP); 62262 (IK)
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
HBDR Series Bulkhead Luminaires
Flameproof
Zone 1, 2, 21 & 22
II 2 GD
ATEX / IEC
IP66 - IK08
Weight
(lbs/kg)
Volume
(in3/dm3)
Pack
Catalog Number
16.53/7.5
51.59/23.4
1
HBDR
Pack
Catalog Number
1
HBDRPGZ
Accessories
Protective Guard
T-Rating for Gas
Operating Positions
Power and Type
Watts
8
15
Type
Compact Fluorescent
Compact Fluorescent
Ambient
Temperature
T Rating
T Rating
Ceiling
Wall
104° F/40° C
T6
T6
122° F/50° C
T6
T6
131°F/55°C
T6
T6
104° F/40° C
T6
T6
122° F/50° C
T6
T6
131°F/55°C
T6
T6
T Rating
T6
T6
T6
T5
T5
T4
Incandescent
200
Incandescent
T Rating
T Rating
T5
T4
T4
T4
T4
T4
T5
T4
T4
T4
T4
T4
100
Mixed
180
Mixed
T° at cable entry
—
183° F/84° C 192° F/89° C
—
183° F/84° C 192° F/89° C
T Rating
T Rating
T° at cable entry
T4
T3
—
T4
T4
T3
T3
188° F/87 C 198° F/92° C
T4
T3
—
T4
T4
T3
T3
189° F/87° C 198° F/92° C
Surface Temperature for Dust
Operating Positions
Power and Type
Ceiling
Wall
Watts
8
15
23
100
Type
Compact Fluorescent
Compact Fluorescent
Compact Fluorescent
Incandescent
Surface T°
for Ta = 131°F/55°C
140° F/60° C
147° F/64° C
156° F/69° C
221° F/105° C
T° at Cable Entry
Ta= 131°F/55°C
–
–
–
–
Surface T°
for Ta = 131°F/55°C
158° F/70° C
169° F/76° C
205° F/96° C
221° F/105° C
T° at Cable Entry
Ta= 131°F/55°C
–
–
–
–
200
Incandescent
266° F/130° C
192° F/89° C
266° F/130° C
192° F/89° C
100
160
Mixed
Mixed
266° F/130° C
300° F/149° C
–
198° F/92° C
266° F/130° C
300° F/149° C
–
198° F/92° C
No need for high temperature cable for cable entry temperature less than 176° F/80° C.
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
1337
Lighting: Increased Safety/Flameproof — Bulkhead
Compact Fluorescent
Lighting
23
100
HBDO Series Bulkhead Luminaires
Flameproof
Zone 1, 2, 21 & 22
II 2 GD
ATEX / IEC
IP66 - IK08
Weight
(lbs/kg)
Volume
(in3/dm3)
Pack
Catalog Number
6.61/3
19.84/9
1
HBDO
Pack
Catalog Number
1
HBDOPGZ
Accessories
Protective Guard
Terminal block for through wiring 0.003 x 0.004 in / 2 x 2.5 mm with high
temperature sleeve
2
2
094784
T-Rating for Gas
Lighting: Increased Safety/Flameproof — Bulkhead
Lighting
Power and Type
Watts
Type
Temperature class for Ta = 104° F/40° C
T° at Cable Input for Ta = 104° F/40° C
7
Compact Fluorescent
T6
—
11
Compact Fluorescent
T6
—
15
Compact Fluorescent
T6
—
60
Incandescent
T4
223° F/106°C
100
Incandescent
T4
223° F/106°C
Watts
Type
Temperature class for Ta = 104° F/40° C
T° at Cable Input for Ta = 104° F/40° C
7
Compact Fluorescent
169° F/76° C
—
11
Compact Fluorescent
169° F/76° C
—
15
Compact Fluorescent
169° F/76° C
—
60
Incandescent
246° F/119° C
223° F/106° C
100
Incandescent
246° F/119° C
223° F/106° C
T-Rating for Dust
Power and Type
No need for high temperature cable for cable entry temperature less than +176 °C/+80 °C.
1338
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
HBDR Series Bulkhead Luminaire Dimensions and Photometric Data
Flameproof
Dimensions in Inches/Millimeters
7.56"/
192 mm
12.99"/
330 mm
(with guard)
6.10"/
155 mm
Ø0.43"/
11 mm
0.51"/
13 mm
6.69"/
170 mm
12.08"/
307 mm
(without guard)
Photometric Data ➊
Lighting
Incandescent
NF C 71-120: .068 G + 0.01 T
Candela
Distribution
0
185
5
178
10
171
15
156
20
132
25
110
30
97
35
87
40
90
45
100
50
96
60
58
70
58
100°
90°
80°
70°
Lighting: Increased Safety/Flameproof — Bulkhead
Degrees
60°
50°
40°
30°
0°
10°
20°
➊ Polar curves for a 1000 lm output according to NF C 71-120 Luminaire symbol according to NF C 71-121.
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
1339
HBDO Series Bulkhead Luminaire Dimensions and Photometric Data
Flameproof
Dimensions in Inches/Millimeters
7.09"/
180 mm
8.66"/
220 mm
4.80"/
122 mm
0.18"/
4.5 mm
6.30"/
160 mm
Photometric Data ➊
Incandescent
NF C 71-120: .068 H
Lighting
Candela
Distribution
67
100°
5
94
10
96
15
99
90°
80°
70°
20
99
60°
25
97
50°
30
95
35
96
40
91
45
91
50
98
60
87
70
69
Lighting: Increased Safety/Flameproof — Bulkhead
Degrees
0
40°
30°
0°
10°
20°
➊ Polar curves for a 1000 lm output according to NF C 71-120 Luminaire symbol according to NF C 71-121.
1340
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
HBN Series Round Bulkhead Luminaires
Flameproof
Zone 2 and 22
II 3 GD
ATEX / IEC
IP65
Applications
•
Suitable for use in:
— Stairways
— Small areas
— Emergency exit
Features
• For incandescent lamps 60 W to 150 W maximum, mixed lamp
100 W maximum, mercury 80 W maximum (remote mercury
ballast not supplied). Lamps not supplied.
• E27 lampholder.
• Screw locking mechanism.
• Operates in all positions.
• Connection to lampholder via two 0.003 x 0.004 in2 /
2 x 2.5 mm2 terminals.
• Internal earth two terminals 0.003 x 0.004 in2 / 2 x 2.5 mm2.
External earth 0.002 x 0.006 in2 / 1 x 4 mm2.
• Three M20 entries in “T” formation. Supplied with one M20
cable gland (dia. 0.26 to 0.57 in / 6.5 to 14.5 mm) and two M20
blanking plugs.
Standard Materials
•
•
•
•
•
HBNRI15 and HBEPGZ
Body: gray painted aluminum alloy
Diffuser: glass
Sealing gasket: silicone
Guard: zinc plated steel
Cable gland and blanking plug: polyamide
Certification Type HBn150
Gas, Zone 2
— Conforming to ATEX 94/9/CE: CE
II 3 G
— ATEX/IEC Protection: Ex nR II
— T Rating: See Table 1
Dust, Zone 22
— Conforming to ATEX 94/9/CE: CE
II 3 D
— ATEX/IEC Protection: Ex tD A22
— Surface Temperature: See Table 1
Ambient Temperature: -4 °F/-20°C Ta 122°F/50°C
-4 °F/-20°C Ta 104 °F/40°C (80 W mercury)
CE Declaration of Conformity: 50220
ATEX Certificate: LCIE 03 ATEX 6167X
IEC Certificate: LCIE Ex 03.026X
Index of Protection (solid & liquid): IP65
Ex Standards: EN / IEC 60079-0; 60079-15; 61241-0; 61241-1
Product Standards: EN / IEC 60598-1
EMC Standards: EN / IEC 55015; 61547
Other Standards: EN / IEC 60529 (IP)
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
Lighting: Increased Safety/Flameproof — Bulkhead
•
•
•
•
•
•
•
•
•
•
•
•
Lighting
Certifications and Compliances
1341
HBN Series Round Bulkhead Luminaires
Flameproof
Zone 2 and 22
II 3 GD
ATEX / IEC
IP65
Weight
(lbs/kg)
Volume
(in3/dm3)
Pack
Catalog Number
6.61/3
33.07/15
1
HBNRI15
Pack
Catalog Number
1
HBEPGZ
Accessories
Protective Guard
HBEGD
Spare Lampglass
T-Rating for Dust and Gas
Lighting: Increased Safety/Flameproof — Bulkhead
Lighting
Power and Type
Dust
Gas
Watts
Type
Surface T° for
Ta = 122 °F/+50 °C
T Rating for
Ta = 104 °F/+40 °C
T Rating for
Ta = 122 °F/+50 °C
T° at Cable Input
60
Incandescent
214 °F/101 °C
T5
T4
—
75
Incandescent
219 °F/104 °C
T5
T4
—
80
Mercury
268 °F/131 °C
(Ta = 104 °F/+40 °C)
T3
—
—
100
Incandescent
237 °F/114 °C
T4
T4
181 °F/83 °C
100
Mixed
257 °F/125 °C
T4
T4
212 °F/100 °C
150
Incandescent
248 °F/120 °C
T4
T4
198 °F/92 °C
1342
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
HBN Series Round Bulkhead Luminaire Dimensions and Photometric Data
Flameproof
Dimensions in Inches/Millimeters
6.81"/173 mm
Cable Entries
Cable
entries
11.65"/296 mm
6.14"/
156 mm
0.24"/
6 mm
6.30"/
160 mm
Protectiveguard
Guard
Protective
Photometric Data ➊
Incandescent
NF C 71-120: .062 J + 0.10 T
0
185
Degrees
178
171
15
156
20
132
30
110
40
97
50
87
60
90
70
100
80
96
90
58
100
58
100°
90°
80°
70°
60°
50°
Lighting: Increased Safety/Flameproof — Bulkhead
5
10
Lighting
Candela
Distribution
40°
30°
0°
10°
20°
➊ Polar curves for a 1000 lm output according to NF C 71-120 Luminaire symbol according to NF C 71-121.
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
1343
HBDC Series Cylindrical Bulkhead Luminaires
Flameproof
Zone 1, 2, 21 & 22
II 2 GD
ATEX / IEC
IPP66/68 (10M) - IK08
Applications
•
For illumination of:
— Stairways
— Small areas
— Emergency exit
Features
•
•
•
•
•
•
•
•
•
For lamps:
— 70 W high pressure sodium (ovoid type E27 lampholder)
— 18/20 W compact fluorescent lamp (E27 lampholder)
— 2 x 40 W incandescent lamp (E27 lampholder)
— 8 W fluorescent bulb (G5 lampholder) (lamp supplied)
HPS version: compensated power supply 230/240 V 50 Hz
(+/-10%) with power factor 0.9.
Connection to plug-in terminal block via 2 x 3 terminals
.025 cm²/2.5 mm².
Operates in any position.
Threaded access cover with O-ring seal.
Two integrated mounting lugs.
1 external earth via .04 cm²/4 mm² bracket.
2 threaded cable entries.
Supplied with 1 plug M20 (cable gland not supplied).
70 W Sodium Version
Compact Fluorescent Version
Lighting
Standard Material
• End cap and cover: Zamak, anticorrosion treated and
painted gray
• Sealed tube: toughened glass
• External reflector: galvanized steel painted white
• Protective guard: zinc plated steel
• Lamps are not supplied except for 8 W fluorescent bulb
Options
Lighting: Increased Safety/Flameproof — Bulkhead
• Fixing accessories available in 316 stainless steel
or zinc plated steel.
• Fall prevention fixing kit in stainless steel.
Certifications and Compliances
•
•
•
•
•
•
•
•
•
•
•
•
•
•
Certification Type: FLd
Zone 1 - 2
— Conforming to ATEX 94/9/CE: CE 0081
II 2 G
— ATEX/IEC Protection: Ex d IIC
— T Rating: See Table
Zone 21 - 22
— Conforming to ATEX 94/9/CE: CE 0081
II 2 D
— ATEX/IEC Protection: Ex tD A21
— Surface Temperature: (See table)
Ambient Temperature: -4 °F/-20 °C ≤ Ta ≤ +131 °F/55 °C
-4 °F/-20 °C ≤ Ta ≤ +131 °F/55 °C for 70W HPS
CE Declaration of Conformity: 50203
ATEX Certificate: LCIE 97/ ATEX 6012
IECEx Certificate: IECEx LCI 04.0018
Other Certifications: GOST
Index of Protection (solid & liquid): IP66 / 68 (10 m)
Impact Resistance (shock): IK08
Internal Volume: > 122 in³/2 dm3 (2 liters)
Ex Standards EN / IEC 60079-0; 60079-1; 61241-0; 61241-1
Product Standards: EN / IEC 60598-1
Other Standards: EN / IEC 60529 (IP); 62262 (IK)
1344
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
HBDC Series Cylindrical Bulkhead Luminaires
Flameproof
Zone 1, 2, 21 & 22
II 2 GD
ATEX / IEC
IPP66/68 (10M) - IK08
Order using catalog numbering guide below or select catalog number from tables on following pages.
Catalog Numbering Guide
HBDC
F
1
Series:
HBDC
40
02A
Quantity of Lamps:
1 - One Lamp
2 - Two Lamp
Lamp Type:
I - Incandescent
F - Fluorescent
L - High Pressure Sodium
Voltage:
02A - 24 Vac 50/60 Hz
02D - 24 Vdc
04A - 48 Vac 50/60 Hz
04D - 48 Vdc
11A - 110 Vac 50/60 Hz
11D - 110 Vdc
24A - 230/240 Vac 50/60 Hz ➍
24B - 230/240 Vac/Vdc 50/60 Hz
Power:
40 - 40 W ➊
18 - 18/20 W ➋
70 - 70 W ➌
08 - 8 W Fluorescent
Weight
lbs/kgs
Volume
in3/dm3
Catalog
Number
Pack
2x40 W Incandescent ➎
E27
–
16/7.1
1892/31
HBDCI240
1
70 W HP Sodium ➎
E27
230/240 Vac 50 Hz
16/7.1
2014/33
HBDCL17024A
1
1x8 W Fluorescent
G5
24 Vdc
18/8.3
1892/31
HBDCF10802D
1
1x8 W Fluorescent
G5
48 Vdc
18/8.3
1892/31
HBDCF10804D
1
1x8 W Fluorescent
G5
110 Vdc
18/8.3
1892/31
HBDCF10811D
1
G5
230/240 Vac 50/60 Hz
18/8.3
1892/31
HBDCF10824B
1
18/8.3
1892/31
HBDCF20824B
1
16/7.1
2014/33
HBDCF118
1
1x8 W Fluorescent
2x8 W Fluorescent
1x18/20 W Compact Fluorescent (1)
Versions
198/254 Vdc
G5
230/240 Vac 50/60 Hz
198/254 Vdc
E27
–
Dust
Gas
Surface Temperature
T Rating
Without
External Reflector
°F/°C
With
External Reflector
°F/°C
Without
External Reflector
Ta=+104 °F/
+40 °C
Ta=+131 °F/
+55 °C
With
External Reflector
Ta=+104 °F/
+40°C
Ta=+131°F/
+55°C
Incandescent lamp (2x40 W)
203/95
203/95
T5
T5
T5
T5
Compact Fluorescent lamp (20 W max)
203/95
266/130
T6
T5
T5
T4
Fluorescent (8 W - G5 lampholder)
203/95
266/130
T6
T5
T5
T4
–
–
High Pressure Sodium Lamp (70 W ovoid)
252/122
–
T4 for Ta = +122 °F/
+50°C
➊ Incandescent Lamp
➋ Compact Fluorescent Lamp
➌ High Pressure Sodium Lamp (HP)
➍ 50 Hz only for the 70 W HPS Version
➎ Lamp not supplied
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
1345
Lighting: Increased Safety/Flameproof — Bulkhead
Voltage
Lighting
Lampholder
Lamp
HBDC Series Cylindrical Bulkhead Luminaires
Flameproof
Zone 1, 2, 21 & 22
II 2 GD
ATEX / IEC
IPP66/68 (10M) - IK08
Accessories
Catalog Number
Packing
External reflector in galvanized steel (painted white)
(not compatible with 70 W HPS version)
Description
FDER1G
1
Protective guard in zinc plated steel
FDPG1Z
1
Protective guard in zinc plated steel for 70 W HPS version
FDPG5Z
1
Quick one-hand fixing (Set of 2 brackets) in zinc plated steel
FDFBZ
1
Quick one-hand fixing (Set of 2 brackets) in 316 stainless steel
FDFBS
1
Fixing unit on flat surface (Set of 2 brackets) in zinc plated steel
FDSBZ
1
Fixing unit on flat surface (Set of 2 brackets) in 316 stainless steel
FDSBS
1
Fixing unit for 1"1/2 (Ø1.93"/49 mm) or 1"1/4 (Ø1.65"/42 mm) tube
in zinc plated steel
FDHC49Z
Fixing unit for 1"1/2 (Ø1.93"/49 mm) or 1"1/4 (Ø1.65"/42 mm) tube
in 316 stainless steel
FDHC49S
Fixing unit for 2" (Ø2.36"/60 mm) tube in zinc plated steel
FDHC60Z
1
1
1
Fixing unit for 2" (Ø2.36"/60 mm) tube in 316 stainless steel
FDHC60S
1
Fall prevention fixing kit (.05"/1.2 m chain) in stainless steel
FDSCS
1
Lighting
Dimensions (In/mm)
HBDCL17024A (70 W HP Sodium)
0.47"/
12 mm
0.98"/
25 mm
7.52"/191 mm
Ø0.47"/
12 mm
Lighting: Increased Safety/Flameproof — Bulkhead
0.59"/
15 mm
3.50"/
89 mm
3.35"/
85 mm
5.91"/
150 mm
0.43"/
11 mm
0.47"/
12 mm
13.19"/
335 mm
0.98"/
25 mm
3.05"/
77.5
77.5 mm
0.43"/
11 mm
Ø0.47"/
12 mm
0.20"/
5.0 mm
15.75"/
400 mm
400
mm
mini
18.50"/
470 mm
0.20"/
5.0 mm
7.52"/191 mm
5.91"/
150 mm
HBDC and HBDCF
3.05"/
77.5
77.5 mm
14.76"/
375 mm
0.59"/
15 mm
3.50"/
89 mm
15.75"/
400 mm
400
mm
mini
16.92"/
430 mm
3.35"/
85 mm
Photometric Data
Polar curves for a 1000 lm flux, according to NF C 71-120
Luminaire symbol according to NF C 71-121
70 W HP Sodium
Efficiency 59.4%
NF C 71-121: 0.56G + 0.04T
2x40 W Incandescent
Efficiency: 75.6%
NFC 71-121: 0.74G + 0.02T
Candela Distribution
0
5
10
15
20
25
30
35
40
45
50
55
60
65
70
1346
0-180 90-270
166
166
167
165
164 Degrees162
162
156
158
151
155
143
151
133
146
122
141
110
135
95
128
81
120
66
111
52
101
39
90
27
Longitudinal
Transverse
Candela Distribution
150° 120°
105°
90°
75°
60°
45°
30°
0°
15°
0
5
10
15
20
25
30
35
40
45
50
60
70
0-180 90-270
196 Degrees 196
197
198
196
196
193
194
189
190
181
185
176
179
170
172
163
164
155
153
145
128
123
91
99
43
100°
90°
80°
70°
60°
50°
40°
30°
0° 10° 20°
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
Baymaster 250/400™ High Bay Luminaires
150 W, 250 W, 400 W HPS; 175 W, 200 W, 250 W, 320 W, 400 W, 450 W PSMH; 175 W, 250 W, 400 W MH V; 300 W-500 W Incandescent.
Applications
• For illumination of manufacturing, storage, and other indoor
areas.
Features
Lighting: General Lighting — Area — High Bay
• Standard Baymaster fixtures operate in high ambient
temperatures. All units suitable for minimum 194 °F/90 °C
supply wire.
• High efficiency (up to 78% with 250 W HPS lamps) with
exceptionally long lamp life—economical to own and operate.
• A wide range of ballasts and voltages are available for both
domestic and export applications.
• Integral ballast.
• Sockets are heavy duty mogul base, with spring loaded, nickel
plated center contact and heavy gauge, nickel plated brass
screw shell with double lamp grips to prevent lamps from
loosening due to vibration.
• Efficient, low glare, compact reflector.
• Reflector installs and adjusts to wide, medium, or narrow
distribution (without tools) by repositioning spring locks.
• Installation is quick and easy:
(1) mount junction box to 0.75”/33.4 mm conduit
(2) slide ballast onto junction box
(3) make connections
(4) install lamp
(5) snap reflector in place.
• Open-top reflector design keeps reflector clean because of
thermal barrier and chimney effect, and provides up-light to
relieve contrast.
Complete Fixture
Standard Materials
•
•
•
•
Ballast: finned, copperfree (4/10 of 1% max.) aluminum
Reflector: aluminum
Sockets: porcelain
Locks: stainless steel
Standard Finishes
• Ballast: white powder coat polyester
• Reflector: natural finished
Dimensions
12.38"/
314.5 mm
• All units available with a sensor circuit for automatically
lighting an auxiliary safety lamp if a power dip or lamp failure
extinguishes the HID lamp.
Lighting
Options
Ballast Housing Assembly
13.75"/349.3 mm
Certifications and Compliances
• UL Listed: E109438
• UL Standard: 1598
• CSA Certified: LR9349
6.25"/
158.8 mm
4.75"/349.3 mm
Related Products
5.5"/139.7 mm
• For power hook, fusing and other suspension accessories, see
Fixture Hanger Accessories page.
15.88"/
403.4 mm Min.
18.25"/
463.6 mm Max
10.38"/
263.7 mm
16"/
406.4 mm
Remote Ballast Mounting
V CSA Certification only.
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
1347
Baymaster 250/400™ High Bay Luminaire Performance
150 W, 250 W, 400 W HPS; 175 W, 200 W, 250 W, 320 W, 400 W, 450 W PSMH; 175 W, 250 W, 400 W MH V
150 Watt
S./M.H. †
Effic.
175 Watt
S./M.H. †
Effic.
250 Watt
S./M.H. †
400 Watt
S./M.H. †
Effic.
Distribution *
Effic.
Narrow
71.0%
.8:1
—
—
80.0%
0.6:1
80.0%
0.6:1
Medium
72.1%
1.5:1
—
—
77.5%
1.4:1
77.6%
1.4:1
Wide
73.2%
2.5:1
—
—
74.6%
2.5:1
75.4%
2.5:1
Pulse Start Metal Halide
• 149 °F/65 °C maximum ambient temperature for 175 W-250 W
• 131 °F/55 °C maximum ambient temperature 320 W-450 W
Distribution *
175 Watt
Effic.
S./M.H. †
200 Watt
Effic.
S./M.H. †
250 Watt
Effic.
S./M.H. †
320 Watt
Effic.
S./M.H. †
400 Watt
Effic.
S./M.H. †
450 Watt
Effic.
S./M.H. †
Narrow
67.7%
0.6:1
73.3%
0.7:1
78.6%
0.2:1
67.5%
0.7:1
67.5%
0.7:1
67.2%
0.7:1
Medium
72.3%
1.4:1
73.8%
1.7:1
75.2%
1.5:1
70.3%
1.6:1
70.6%
1.6:1
70.7%
1.4:1
Wide
74.6%
2.0:1
72.8%
2.2:1
74.1%
2.1:1
70.6%
2.1:1
71.4%
2.1:1
71.6%
2.0:1
Metal Halide V
• 149 °F/65 °C maximum ambient temperature for 175 W-250 W
• 131 °F/55 °C maximum ambient temperature 400 W
175 Watt
250 Watt
400 Watt
Distribution *
Effic.
S./M.H. †
Effic.
S./M.H. †
Effic.
S./M.H. †
Narrow
82.9%
0.8:1
82.9%
0.8:1
79.6%
1:1
Medium
82.8%
1.8:1
82.8%
1.8:1
77.2%
2:1
Wide
80.4%
2.4:1
80.4%
2.4:1
75.2%
2.7:1
Lighting
Lighting: General Lighting — Area — High Bay
High Pressure Sodium
• 149 °F/65 °C maximum ambient temperature for 150 W-250 W
• 131 °F/55 °C maximum ambient temperature 400 W
V CSA Certification only.
1348
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
Baymaster 250/400™ High Bay Luminaire Electrical Specifications
150 W, 250 W, 400 W HPS; 175 W, 200 W, 250 W, 320 W, 400 W, 450 W PSMH; 175 W, 250 W, 400 W MH V
High Pressure Sodium — All ballasts are C.W.A. type, except 150 W HPS which is HX-Auto
150 W
Line
Volts
Start
120
2.00
250 W
Oper.
Total
Watts
Start
1.70
188
2.00
400 W
Oper.
Total
Watts
Start
Oper.
Total
Watts
2.50
295
3.30
3.80
465
208
1.15
.95
188
1.20
1.50
295
1.80
2.20
465
240
1.00
.85
188
1.00
1.30
295
1.60
1.90
465
277
.85
.72
188
.85
1.10
295
1.40
1.70
465
347 V 0.52
0.56
188
0.60
0.93
295
1.00
1.32
465
.47
189
.40
.65
295
.80
1.00
465
480
.50
Line
Volts
Start
Oper.
200 W
Total
Watts
Start
Oper.
Pulse Start Metal Halide — Super C.W.A. Ballast Amps
250 W
320 W
Total
Total
Total
Watts Start Oper. Watts Start Oper. Watts Start
400 W
Oper.
450 W
Total
Watts
Start
Oper.
Total
Watts
120
.90
1.78
199
2.10
2.00
235
1.90
2.50
288
2.60
3.25
368
3.50
4.00
454
4.00
4.40
510
208
.50
1.08
199
1.15
1.25
235
1.10
1.45
288
1.50
1.90
368
2.00
2.30
454
2.30
2.60
510
240
.35
.89
199
1.10
1.00
235
.96
1.25
288
1.30
1.65
368
1.75
2.00
454
2.00
2.20
510
277
.30
.76
199
.75
.85
235
.85
1.10
288
1.15
1.40
368
1.50
1.75
454
1.70
1.90
510
347 V 0.25
0.65
199
.25
.70
232
0.62
0.90
288
0.70
1.10
368
1.10
1.35
454
1.10
1.50
505
.50
213
.35
.50
237
.46
.60
285
.60
.80
368
.90
1.00
454
.85
1.12
514
480
.25
175 W
Line
Volts
Start
Oper.
Total
Watts
120
1.3
1.8
213
Metal Halide V — C.W.A. Ballast Amps
250 W
Total
Start Oper. Watts
Start
Oper.
Total
Watts
1.2
3.25
4.0
458
2.6
295
400 W
.75
1.1
213
.65
1.5
295
1.9
2.3
458
.65
.90
213
.60
1.3
295
1.65
2.0
458
277
.55
.78
213
.50
1.12
295
1.4
1.75
458
347
0.50
0.65
213
0.80
0.90
295
1.20
1.40
458
Lighting
208
240
V CSA Certified only.
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
Lighting: General Lighting — Area — High Bay
175 W
1349
Baymaster 250/400™ High Bay Luminaires
Quick Estimate Illumination Charts *
Lighting
Lighting: General Lighting — Area — High Bay
150 W, 250 W, 400 W HPS; 175 W, 200 W, 250 W, 320 W, 400 W, 450 W PSMH; 175 W, 250 W, 400 W MH V
400 Watt High Pressure Sodium
400 Watt Pulse Start Metal Halide
250 Watt High Pressure Sodium
250 Watt Pulse Start Metal Halide
How to use Quick-Estimate Illumination Chart
1. Refer to “Quick-Estimate Illumination Chart” for the lamp type and wattage to be used.
2. Determine “room size” of area to be lighted. “Small Room” is 2500 Sq. Ft. or less. “Medium Room” is 2500 Sq. Ft./232.2 Sq.M. thru
10,000 Sq. Ft./929.0 Sq. M. A “Large Room” is 10,000 Sq. Ft./929.0 Sq. M. or more.
3. Find level of light (footcandles) required in vertical column of figures at left of chart. Then follow horizontal line (real or interpolated)
to right until it intersects with “Arc” of selected “room size.” Come directly down from point of intersection to horizontal line of number
“Square Feet Per Luminaire.” The resulting number (real or interpolated) is the “number of square feet” one Appleton Baymaster will
illuminate to the selected average maintained footcandle level when mounted in conjunction with other units in the high bay installation.
4. Divide number of total square feet in project by “number of square feet per luminaire” to get number of units required.
5. Take square root of resulting “number of square feet per luminaire” number to determine spacing between units.
* Photometric charts available on request.
V CSA Certification only.
1350
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
Baymaster 250/400™ High Bay Luminaires
150 W, 250 W, 400 W HPS; 175 W, 200 W, 250 W, 320 W, 400 W, 450 W PSMH; 175 W, 250 W, 400 W MH V
Pendant Mounting (3/4”)
Lamp Type
Catalog Number
Ballast Housing Assembly
Voltage
Complete Assembly ➊➋
150 W HPS
120/208/240/277 V
G-HB41AL-MT
G-HB411L-MT
150 W HPS
120/277/347 V
G-HB41AL-TT V➌
G-HB411L-TT V➌
150 W HPS
480 V
G-HB41AL-48
G-HB411L-48
250 W HPS
120/208/240/277 V
G-HB61AL-MT
G-HB611L-MT
250 W HPS
120/277/347 V
250 W HPS
480 V
G-HB61AL-TT V➌
G-HB61AL-48
G-HB611L-TT V➌
G-HB611L-48
400 W HPS
120/208/240/277 V
G-HB71AL-MT
G-HB711L-MT
400 W HPS
120/277/347 V
400 W HPS
480 V
G-HB71AL-TT V➌
G-HB71AL-48
G-HB711L-TT V➌
G-HB711L-48
G-HB51AP-MT
G-HB511P-MT
G-HB51AP-TT V➌
G-HB51AP-48
G-HB511P-TT V➌
G-HB511P-48
G-HB201AP-MT
G-HB2011P-MT
G-HB201AP-TT V➌
G-HB201AP-48
G-HB2011P-TT V➌
G-HB2011P-48
G-HB61AP-MT
G-HB611P-MT
G-HB61AP-TT V➌
G-HB61AP-48
G-HB611P-TT V➌
G-HB611P-48
G-HB321AP-MT
G-HB3211P-MT
G-HB321AP-TT V➌
G-HB321AP-48
G-HB3211P-TT V➌
G-HB3211P-48
G-HB71AP-MT
G-HB711P-MT
G-HB71AP-TT V➌
G-HB71AP-48
G-HB711P-TT V➌
G-HB711P-48
G-HB451AP-MT
G-HB4511P-MT
G-HB451AP-TT V➌
G-HB451AP-48
G-HB4511P-TT V➌
G-HB4511P-48
For High Pressure Sodium Lamps
Lighting: General Lighting — Area — High Bay
For Pulse Start Metal Halide Lamps
120/208/240/277 V
175 W PSMH
120/277/347 V
175 W PSMH
480 V
200 W PSMH
120/208/240/277 V
200 W PSMH
120/277/347 V
200 W PSMH
480 V
250 W PSMH
120/208/240/277 V
250 W PSMH
120/277/347 V
250 W PSMH
480 V
320 W PSMH
120/208/240/277 V
320 W PSMH
120/277/347 V
320 W PSMH
480 V
400 W PSMH
120/208/240/277 V
400 W PSMH
120/277/347 V
400 W PSMH
480 V
450 W PSMH
120/208/240/277 V
450 W PSMH
120/277/347 V
450 W PSMH
480 V
Lighting
175 W PSMH
For Metal Halide Lamps V
175 W MH
120/208/240/277 V
G-HB51AH-MT V
G-HB511H-MT V
175 W MH
120/277/347 V
G-HB51AH-TT V➌
G-HB511H-TT V➌
250 W MH
120/208/240/277 V
G-HB61AH-MT V
G-HB611H-MT V
250 W MH
120/277/347 V
G-HB61AH-TT V➌
G-HB611H-TT V➌
400 W MH
120/208/240/277 V
G-HB71AH-MT V
G-HB711H-MT V
400 W MH
120/277/347 V
G-HB71AH-TT V➌
G-HB711H-TT V➌
➊ Add suffix -E to catalog number if provision for 250 W quartz emergency lamp is desired (lamp not included). Furnished with socket installed and pre-wired
(not available on units for remote ballast).
➋ To order fixture complete with lamp, add suffix -L to catalog number.
➌ Supplied complete with CWA Ballast. For 208, 240, 480 or 600 V CWI applications, change the -TT suffix to -C2, -C3, -C6 or -C7 as required. V
V CSA Certification only.
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
1351
Baymaster 250/400™ High Bay Luminaire Accessories and Replacement Parts
150 W, 250 W, 400 W HPS; 175 W, 200 W, 250 W, 320 W, 400 W, 450 W PSMH; 175 W, 250 W, 400 W MH V; 300 W-500 W Incandescent.
For Incandescent Lamps or HID lamps and Remote Ballast ➊
Lamp Type
Voltage
Catalog Number➑
For Incandescent Lamps or HID lamps and Remote Ballast ➊
300 W-500 W PS-35, incandescent
G-H71AM-RB
250 W-400 W, HPS
G-H71AL-RB
250 W, PSMH/MH
G-H71AM-RB
400 W, PSMH/MH
G-H71AM-RB
Accessories and Replacement Parts
Type
Description
Catalog Number
Lighting: General Lighting — Area — High Bay
Glass Lenses ➋
1.0"/
25.4 mm
With clear, thermal shock and impact
resistant glass lens.
G-HB7000-NL
With prismatic Corning-73 thermal shock
and impact resistant lens.
G-HB7000-NL3
Reflector only.
G-7AW
Aluminum, with gasket
(closes off reflector).
G-HB7000-SS
Has relamp opening, zinc plated.
G-HB7000-NG
16.06"/407.9 mm
Reflector
Socket Shroud
2.25"/
57.2 mm
3.0"/
76.2 mm
2.88"/73.2 mm
6.0"/
152.4 mm
Lighting
Wire Guard
1.0"/
25.4 mm
16.75"/
425.5 mm
Safety Cable (not shown)
G-HB7000-SC
Fuseholder
Has 9”/228.6 mm wire leads.
G-F10
Supplied with 3 feet of 16/3 SOOW cable
and FHHM-75SS cast safety hook
PWK V
1.31"/
33.3 mm
Wiring Kit (not shown)
➊ For remote ballast consult your local sales representative.
➋ Lens assemblies shown have stainless steel frame and are furnished with an aluminum socket shroud to close off reflector top (shroud shown). Can be field
installed.
V CSA Certification only.
1352
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
Baymaster Prismatic 250/400™ High Bay Luminaires
150 W, 250 W, 400 W HPS. 400 W PSMH. 400 W MH V.
Applications
• For illumination of manufacturing, storage, and other indoor
areas.
Features
Lighting: General Lighting — Area — High Bay
• Standard Baymaster fixtures operate in 104 °F/40 °C ambient
temperatures. All units suitable for minimum 194 °F/90 °C
supply wire.
• High efficiency (up to 78% with 250 W HPS lamps) with
exceptionally long lamp life—economical to own and operate.
• A wide range of ballasts and voltages are available for both
domestic and export applications.
• Integral ballast.
• Mogul base sockets with spring loaded center contact and
heavy guage screw shell with double lamp grips to prevent
lamps from loosening due to vibration.
• Efficient, low glare, compact reflector is UV stabilized,
clear, injection molded high-temperature acrylic that provides
15-20% uplight.
• Reflector installs and adjusts to wide, medium, or narrow
distribution (without tools) by repositioning spring locks.
• Installation is quick and easy:
(1) mount junction box to 3/4”/19.1 mm conduit
(2) slide ballast onto junction box
(3) make connections
(4) install lamp
(5) snap reflector in place
• Open-top reflector design keeps reflector clean because of
thermal barrier and chimney effect, and provides up-light to
relieve contrast.
Dimensions
Standard Materials
•
•
•
•
Ballast: finned, aluminum
Sockets: heavy duty porcelain
Reflector: acrylic
Locks: stainless steel
25.0"/635.0 mm
26.0"/660.4 mm
Standard Finishes
27.25"/692.2 mm
Lighting
• Ballast: corrosion polyester
• Sockets: nickel plated center contact
• Screws: nickel plated brass
Options
• All units available with a sensor circuit for automatically
lighting an auxiliary safety lamp if a power dip or lamp failure
extinguishes the HID lamp.
16.25"/
412.8 mm
Certifications and Compliances
• UL Listed: E109438
• UL Standard: 1598
• CSA Certified: LR9349
Related Products
• For power hook, fusing and other suspension accessories, see
Fixture Hanger Accessories page.
V CSA Certification only.
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
1353
Baymaster Prismatic 250/400™ High Bay Luminaires
150 W, 250 W, 400 W HPS. 400 W PSMH. 400 W MH V.
Pendant Mounting
Lamp Type
Voltage
Complete Assembly ➊
Catalog Number
Ballast Housing Assembly
Lighting: General Lighting — Area — High Bay
For High Pressure Sodium Lamps
G-HB41PL-MT
G-HB411L-MT
G-HB41PL-TT V➋
G-HB411L-TT V➋
480
G-HB41PL-48
G-HB411L-48
250 W HPS
120/208/240/277 V
G-HB61PL-MT
G-HB611L-MT
250 W HPS
120/277/347 V
G-HB61PL-TT V➋
G-HB611L-TT V➋
250 W HPS
480
G-HB61PL-48
G-HB611L-48
400 W HPS
120/208/240/277 V
G-HB71PL-MT
G-HB711L-MT
400 W HPS
120/277/347 V
G-HB71PL-TT V➋
G-HB711L-TT V➋
400 W HPS
480
G-HB71PL-48
G-HB711L-48
400 W PSMH
120/208/240/277 V
G-HB71PP-MT
G-HB711P-MT
400 W PSMH
120/277/347 V
G-HB71PP-TT V➋
G-HB711P-TT V➋
400 W PSMH
480
G-HB71PP-48
G-HB711P-48
150 W HPS
120/208/240/277 V
150 W HPS
120/277/347 V
150 W HPS
For Pulse Start Metal Halide Lamps
For Metal Halide Lamps V
400 W MH
120/208/240/277 V
G-HB71PH-MT V
G-HB711H-MT V
400 W MH
120/277/347 V
G-HB71PH-TT V➋
G-HB711H-TT V➋
Accessories
Lighting
Description
Catalog Number
16” Prismatic Reflector only.
G-7PR
16” Prismatic Reflector with clamp band and clear tempered glass lens.
G-7PR-IL V
16” Prismatic Reflector with clamp band and prismatic acrylic lens.
G-7PR-ILP V
➊ To order fixture complete with lamp, add suffix -L to catalog number.
➋ Supplied complete with CWA Ballast. For 208, 240, 480 or 600 V CWI applications, change the -TT suffix to -C2, -C3, -C6 or -C7 as required. V
V CSA Certification only.
1354
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
Baymaster Prismatic 250/400™ High Bay Luminaire Electrical Specifications
150 W, 250 W, 400 W HPS. 400 W PSMH. 400 W MH V.
• Ballast has primary taps for 120, 208, 240 and 277 Volts.
• Add suffix -E to catalog number if provision for 150 W quartz emergency lamp is desired (lamp not included). Furnished with socket
installed and pre-wired.
• 400 W MH lamps: some manufacturers recommend that their lamps be operated in enclosed units only—contact your lamp distributor or
lamp manufacturer for the latest safety information.
• To order fixture complete with lamp, add suffix -L to catalog number.
High Pressure Sodium — All ballasts are C.W.A. type, except 150 W HPS which is HX-Auto
150 W
Line
Volts
Start
Oper.
250 W
Total
Watts
Start
Oper.
400 W
Total
Watts
Start
Oper.
Total
Watts
2.00
1.70
188
2.00
2.50
295
3.30
3.80
465
1.15
.95
188
1.20
1.50
295
1.80
2.20
465
240
1.00
.85
188
1.00
1.30
295
1.60
1.90
465
277
.85
.72
188
.85
1.10
295
1.40
1.70
465
347 V 0.52
0.56
188
0.60
0.93
295
1.00
1.32
465
.47
189
.40
.65
295
.80
1.00
465
480
.50
Oper.
Total
Watts
Start
Oper.
Pulse Start Metal Halide — Super C.W.A. Ballast Amps
250 W
320 W
Total
Total
Total
Watts Start Oper. Watts Start Oper. Watts Start
.90
1.78
199
2.10
2.00
235
1.90
175 W
Line
Volts
Start
120
200 W
2.50
288
2.60
3.25
368
3.50
400 W
450 W
Oper.
Total
Watts
Start
Oper.
Total
Watts
4.00
454
4.00
4.40
510
208
.50
1.08
199
1.15
1.25
235
1.10
1.45
288
1.50
1.90
368
2.00
2.30
454
2.30
2.60
510
240
.35
.89
199
1.10
1.00
235
.96
1.25
288
1.30
1.65
368
1.75
2.00
454
2.00
2.20
510
277
.30
.76
199
.75
.85
235
.85
1.10
288
1.15
1.40
368
1.50
1.75
454
1.70
1.90
510
347 V 0.25
0.65
199
.25
.70
232
0.62
0.90
288
0.70
1.10
368
1.10
1.35
454
1.10
1.50
505
.50
213
.35
.50
237
.46
.60
285
.60
.80
368
.90
1.00
454
.85
1.12
514
480
.25
Line
Volts
Start
Oper.
Total
Watts
Lighting
175 W
Metal Halide V — C.W.A. Ballast Amps
250 W
Total
Start Oper. Watts
Start
400 W
Oper.
Total
Watts
120
1.3
1.8
213
1.2
2.6
295
3.25
4.0
458
208
.75
1.1
213
.65
1.5
295
1.9
2.3
458
240
.65
.90
213
.60
1.3
295
1.65
2.0
458
277
.55
.78
213
.50
1.12
295
1.4
1.75
458
347
0.50
0.65
213
0.80
0.90
295
1.20
1.40
458
V CSA Certified only.
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
Lighting: General Lighting — Area — High Bay
120
208
1355
Baymaster Prismatic 250/400™ High Bay Luminaires
Quick-Estimate Illumination Charts *
Lighting
Lighting: General Lighting — Area — High Bay
150 W, 250 W, 400 W HPS. 400 W PSMH. 400 W MH V.
400 Watt High Pressure Sodium
400 Watt Pulse Start Metal Halide
250 Watt High Pressure Sodium
250 Watt Pulse Start Metal Halide
How to use Quick-Estimate Illumination Chart
1. Refer to “Quick-Estimate Illumination Chart” for the lamp type and wattage to be used.
2. Determine “room size” of area to be lighted. “Small Room” is 2500 Sq. Ft. or less. “Medium Room” is 2500 Sq. Ft. thru 10,000 Sq. Ft. A
“Large Room” is 10,000 Sq. Ft. or more.
3. Find level of light (footcandles) required in vertical column of figures at left of chart. Then follow horizontal line (real or interpolated) to
right until it intersects with “Arc” of selected “room size.” Come directly down from point of intersection to horizontal line of number
“Square Feet Per Luminaire.” The resulting number (real or interpolated) is the “number of square feet” one Appleton Baymaster will
illuminate to the selected average maintained footcandle level when mounted in conjunction with other units in the high bay installation.
4. Divide number of total square feet in project by “number of square feet per luminaire” to get number of units required.
5. Take square root of resulting “number of square feet per luminaire” number to determine spacing between units.
* Photometric charts available on request.
* Photometric charts available on request.
V CSA Certification only.
1356
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
Baymaster Prismatic 250/400™ High Bay Luminaire Photometric Data *
150 W, 250 W, 400 W HPS. 400 W PSMH. 400 W MH V.
Square Steel Poles for Davit Mount Luminaires
Typical Footcandle Values
30
—
—
—
—
—
—
—
—
—
—
—
.01
.01
.02
.03
.05
.07
.10
.14
.23
.55
40
—
—
—
—
—
.01
.01
.01
.02
.03
.04
.05
.06
.08
.10
.21
.37
.60
.91
1.35
1.91
50
.01
.01
.01
.02
.02
.03
.03
.04
.05
.06
.10
.17
.26
.38
.54
.74
1.00
1.29
1.62
2.05
2.69
400 Watt High Pressure Sodium
60
.02
.03
.03
.04
.04
.06
.09
.14
.20
.27
.35
.46
.60
.77
.93
1.13
1.37
1.66
2.02
2.16
2.21
Lighting: General Lighting — Area — High Bay
165
160
155
150
145
140
135
130
125
120
115
110
105
100
95
90
85
80
75
70
65
Mounting Height Feet
Distance in terms of mounting height ◊
Distance (ft)
Ahead/
Behind
Footcandle
Distance in terms of mounting height ◊
1.06
2.53
9.07
2.21
1.85
3.39
3.17
2.18
400 W HPS
50
45
40
35
30
25
20
15
10
5
0
-5
-10
-15
-20
-25
-30
3.08
4.51
6.64
8.65
8.85
8.95
9.25
11.4
13.7
12.7
6.58
1.15
.60
.77
1.13
1.11
.85
4.55
4.93
4.98
4.98
5.04
5.49
6.41
7.47
7.67
6.53
3.70
.81
.40
.31
.43
.59
.70
3.19
3.16
3.23
3.18
3.63
4.10
4.64
4.95
4.83
3.93
2.37
.58
.33
.23
.21
.26
.35
2.34
2.24
2.31
2.57
2.85
3.16
3.43
3.41
3.18
2.60
1.65
.48
.29
.18
.15
.15
.19
Mtg. Ht.
20
25
30
35
40
45
Ft. Candles for Iso-Footcandle Lines
A
29.03
18.58
12.90
9.48
7.26
5.73
B
20.21
12.91
8.98
6.60
5.05
4.00
C
19.19
12.28
8.53
6.27
4.80
3.79
D
8.07
5.16
3.59
2.63
2.02
1.59
E
2.39
1.53
1.06
.78
.60
.47
F
G
.39
.25
.17
.13
.10
.08
H
.17
.11
.08
.06
.04
.03
.04
.04
.03
.02
.02
.01
This report has been prepared in accordance with IES guides on testing procedures. It is
representative of luminaires tested under standardized and stabilized laboratory conditions.
Various operating factors can cause differences between laboratory data and actual field
performance.
◊ Distance in terms of mounting height (i.e., ratio) of distance to height. Example: @ 15 foot/4.6 meters mounting height, 1 means 15 foot/4.6 meters; 2 means
30 foot/9.1 meters, etc.
* Additional photometric charts available on request.
V CSA Certification only.
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
1357
Lighting
60
55
Super-Baymaster High Bay Luminaires V
High Bay Luminaires for Mill Duty and Corrosive Atmospheres
150 W, 175 W, 250 W, 400 W or 1000 W HID lamps.
Applications
• For illumination of mills (pulp and paper), manufacturing, storage
and other areas where corrosion, moisture or dust present
severe problems.
• CSA approved weatherproof (Encl. 3) with open reflector and
dust-tight (Encl. 3 and 5) with enclosing lens.
• Will operate safely in temperatures ranging from -40 °F/-40 °C
to +149 °F/+65 °C ambient.
Lighting
Lighting: General Lighting — Area — High Bay
Features
• Corrosion resistant. All external surfaces of the ballast housing
are coated with a heavy-duty epoxy-finish providing
durability and resistant to both alkali and acidic atmospheric
conditions. To suit specific atmospheric requirements,
consult the factory for a suitable finish.
• High efficiency reflectors (up to 76% with 1000 W MH lamps)
and exceptionally long HID lamp life make Super-Baymaster
luminaires unusually economical to own and operate.
• The Baymaster reflector is a unique design that combines high
efficiency with low glare in a compact size.
• Super-Baymaster luminaires are furnished with open reflectors.
For enclosed reflectors, clear or prismatic glass are available.
• Pre-wired with high temperature fixture wire, these integral
ballasted luminaires are supplied with dual-tap primary for 120
or 240 Volt lines or with 208, 277 or 347 Volt primary. Ballasts
are highest quality, Class H insulated, CWA and CWI types,
thermally isolated for cooler operating and
long life. Grounding wire provided.
• To protect the internal components of the luminaire from
corrosive atmospheres all mating surfaces are gasketed.
• Mogul base socket with spring loaded center contact and heavy
gauge, screw shell with double lamp grips to prevent lamps
from loosening due to vibration.
• Installation is quick and easy:
(1) lift ballast assembly onto the hanger hub and rotate 60° until
sealed on hub
(2) tighten locking nut (hand tight) to secure ballast assembly
(3) make supply connections (90° wire) and replace wiring cover
(4) snap reflector in place
(5) install lamp
Shown with optional lens: 1000 W
Dimensions
Height
20-7/8"/530.4 mm; 150-400 W MV/MH
19-11/16"/500.1 mm; 1000 W
Width
16"/406.4 mm; 150-400 W
20"/508.0 mm; 1000 W
Height
29"/736.6 mm; 150-400 W MV/MH
31"/787.4 mm; 1000 W
Standard Materials
• Reflector: aluminum
• Sockets: porcelain
Width
16"/406.4 mm; 150-400 W
20"/508.0 mm; 1000 W
Standard Finishes
• Screws: nickel plated brass
• Housing: epoxy powder coated external surfaces
Options
• Quartz auxiliary: units are available with a pre-wired sensor
circuit for automatically lighting a quartz auxiliary lamp when
power dip or lamp failure extinguishes the main HID lamp.
• Fuse kits: for grounded systems.
• Lenses: clear or prismatic glass with heavy-duty, stainless steel
clips to secure lens to reflector.
• HPS units available with a pulse eliminator which effectively
shuts down the ballast assembly when lamp fails.
• Optional finishes may be ordered to suit specific environments
in regular or specific colors.
Certifications and Compliances
•
•
•
•
UL Listed: E109938
UL Standard: 1598
CSA Certified: 009349
CSA Standard: C22.2 No. 250.0
Related Products
• For power hook, fusing and other suspension accessories, see
Fixture Hanger Accessories page.
V CSA Certification only.
1358
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
Super-Baymaster High Bay Luminaires V
High Bay Luminaires for Mill Duty and Corrosive Atmospheres
150 W, 175 W, 250 W, 400 W or 1000 W HID lamps.
Order using catalog numbering guide below or select catalog number from tables on following pages.
Catalog Numbering Guide for GSB and GSS
GSB
4
Series:
GSB – SuperBaymaster
GSS – SuperBaymaster
Side by Side
1
A
Beam Spread:
1 – Narrow (not for
1000 W)
2 – Medium
3 – Wide
C
Lamp Type:
L – High Pressure Sodium
H – Metal Halide
M – Mercury Vapour
P – Pulse Start Metal Halide
Reflector:
A – Complete with reflector
Blank – Ballast assembly only
MT
E
Voltage:
MT – 120, 208,
240, 277V
CWA
TT – 120, 277,
347V CWA
208 – 208 Volts
RB – Remote
Ballast
Ballast Type:
C – CWI
A – CWA
Voltage:
E – Provision for 250 W
quartz emergency
lamp (pre-wired)
S – Provision for pulse
eliminator
F – Fuse for grounded
systems (single
pole)
LC – Gasketed clear
lens assembly
LP – Gasketed
prismatic lens
assembly
CR – Corrosion
resistant epoxy
paint on reflector
exterior surface
Lighting: General Lighting — Area — High Bay
Wattage:
4 – 150 watt
5 – 175 watt
6 – 250 watt
7 – 400 watt
8 – 1000 watt
L
Accessories and Replacement Parts
Description
Catalog Number
With relamp door. Zinc plated
G-HB-20-G
Safety Chain
Secures ballast and reflector
G-HB-7000-SC
Wiring Kit
Supplied with 3 feet of 600V –194 °F/90
°C 3-conductor no. 16 SOW cable and
3/4”/19.1 mm FHHM hook (shipped
separately) Add Suffix:
Lighting
Wire Guard
PWK
Sockets
Socket for Metal Halide and Mercury Vapor
SPF-1004
Socket for High Pressure Sodium
SPF-1001
V CSA Certification only.
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
1359
Super-Baymaster High Bay Luminaires V
High Bay Luminaires for Mill Duty and Corrosive Atmospheres
150 W, 175 W, 250 W, 400 W or 1000 W HID lamps.
Luminaire Performance
Distribution
150 Watt
Effic.
S./M.H.
200 Watt
Effic.
S./M.H.
250 Watt
Effic.
S./M.H.
400 Watt
Effic.
S./M.H.
1000 Watt
Effic.
S./M.H.
High Pressure Sodium
Narrow
66.3%
0.5:1
66.4%
0.5:1
68.9%
0.5:1
66.4%
0.5:1
—
—
Medium
71.3%
1.1:1
71.4%
1.1:1
74.4%
1.7:1
71.4%
1.1:1
71.3%
0.7:1
Wide
73.3%
2.0:1
73.4%
2.0:1
78.0%
2.0:1
73.5%
2.0:1
74.4%
1.4:1
Effic.
175 Watt
S./M.H.
Effic.
250 Watt
S./M.H.
Effic.
400 Watt
S./M.H.
Effic.
1000 Watt
S./M.H.
Metal Halide
Narrow
61.8%
0.4:1
66.7%
0.4:1
61.9%
0.6:1
—
—
Medium
66.1%
1.0:1
70.2%
1.0:1
66.3%
1.5:1
76.2%
1.1:1
Wide
66.1%
2.0:1
75.2%
2.2:1
66.3%
2.2:1
75.4%
2.5:1
Mercury Vapor
Narrow
73.0%
0.8:1
53.2%
0.8:1
73.1%
1.2:1
—
—
Medium
73.5%
1.1:1
63.2%
1.1:1
73.6%
1.4:1
72.1%
1.5:1
Wide
74.2%
1.7:1
68.0%
1.7:1
74.2%
1.7:1
69.5%
1.8:1
Quick-Estimate Illumination Charts
1000 Watt High Pressure Sodium
1000 Watt Metal Halide
1000 Watt Mercury Vapor
Lighting
Lighting: General Lighting — Area — High Bay
Distribution
How to use Quick-Estimate Illumination Chart
1. Refer to “Quick-Estimate Chart” for the lamp to be used.
2. Determine “room size” of area to be lighted. “Small Room” is 2500 Sq. Ft./232.3 Sq. M. or less. “Medium Room” is 2500 Sq. M./232.3
Sq. M. thru 10,000 Sq. Ft./929.0 Sq. M. “Large Room” is 10,000 Sq. Ft./929.0 Sq.M. or more.
3. Find level of light (footcandles) required in vertical column of figures at left of chart. Then follow horizontal line
(real or interpolated) to right until it intersects with “Arc” of selected “room size.” Come directly down from point
of intersection to horizontal line of number “Square Feet Per Luminaire”. The resulting number (real or interpolated)
is the “number of square feet” one Appleton Baymaster will illuminate to the selected average maintained footcandle
level when mounted in conjunction with other units in the high bay installation.
4. Divide number of total square feet in project by “number of square feet per luminaire” to get number of units required.
5. Take square root of resulting “number of square feet per luminaire” number to determine spacing between units.
S./M.H.: Spacing to Mounting Height.
Photometric charts available on request.
V CSA Certification only.
1360
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
Baymaster 1000™ High Bay Luminaires
1000 W HPS; 1000 W MH; 750 W, 1000 W, 1500 W PS-52 Incandescent.
Applications
• Ideal for aircraft hangars, machine shops, foundries and other
large-area working environments.
Features
Complete Fixture
Standard Materials
•
•
•
•
•
Ballast: finned, aluminum
Sockets: porcelain, nickel plated center contact
Screws: brass
Reflectors: aluminum
Locks: stainless steel
Lighting: General Lighting — Area — High Bay
• Standard Baymaster fixtures operate in high ambient
temperatures.
• High efficiency (up to 76% with 1000 W metal halide lamps) with
exceptionally long lamp life makes these Baymaster fixtures
unusually economical to own and operate.
• A wide range of ballasts and voltages are available for both
domestic and export applications.
• Integral ballast.
• Mogul base socket with spring loaded center contact and heavy
gauge, screw shell with double lamp grips to prevent lamps
from loosening due to vibration.
• The Baymaster reflector is a unique design that combines high
efficiency with low glare in a compact size.
• Reflector installs and adjusts to wide or medium distribution
(without tools) by repositioning spring locks.
• Installation is quick and easy:
(1) lift ballast assembly onto the hanger hub and rotate 60° until
seated on hub
(2) tighten locking nut (hand tight) to secure ballast assembly
(3) make supply connections (194 °F/90 °C wire) and replace
wiring cover
(4) snap reflector in place
(5) install lamp
• Open-top reflector design keeps reflector clean because of
thermal barrier and chimney effect, and provides up-light to
relieve contrast.
Ballast Housing Assembly
Dimensions
Ballast: corrosion polyester
Sockets: nickel plated center contact
Screws: nickel plated
Reflectors: natural finish
26.81”/681.0 mm Min. — 29”/736.6 mm Max.
•
•
•
•
Options
• Units are available with a pre-wired sensor circuit for
automatically lighting an auxiliary safety lamp in case a power
dip or lamp failure extinguishes the HID lamp.
Certifications and Compliances
• UL Listed: E109438
• UL Standard: 1598 (supersedes UL Standard 1572)
• CSA Certified: LR9349
Related Products
• For power hook, fusing and other suspension accessories, see
Fixture Hanger Accessories page.
Lighting
Standard Finishes
20.0"/508.0 mm
Standard Baymaster 1000 fixtures operate
efficiently in high 131 °F/55 °C ambient temperatures.
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
1361
Baymaster 1000™ High Bay Luminaires
1000 W HPS; 1000 W MH; 750 W, 1000 W, 1500 W PS-52 Incandescent.
Pendant Mounting (3/4”)
Lamp Type
Catalog Number
Complete Assembly ②
Ballast Housing Assembly
Voltage
For High Pressure Sodium Lamps — Complete with ballast
G-HB81AL-MT
G-HB811L-MT
G-HB81AL-TT V
G-HB811L-TT V
480 V
G-HB81AL-48
G-HB811L-48
1000 W MH
120/208/240/277 V
G-HB81AH-MT
G-HB811H-MT
1000 W MH
120/277/347 V
1000 W MH
480 V
1000 W HPS
120/208/240/277 V
1000 W HPS
120/277/347 V
1000 W HPS
Lighting
Lighting: General Lighting — Area — High Bay
For Metal Halide Lamps — Complete with ballast
G-HB81AH-TT V
G-HB811H-TT V
G-HB81AH-48
G-HB81A1H-48
750 W, 1000 W or 1500 W PS-52 Incandescent
G-H81AM-RB
G-H811M-RB
1000 W High Pressure Sodium
G-H81AL-RB
G-H811L-RB
1000 W Metal Halide
G-H81AH-RB
G-H811H-RB
For Incandescent Lamps or HID Lamps — Ballast Remote — Ballast not included
Electrical Specifications
Line Volts
120
High Pressure Sodium — C.W.A. Ballast Amps — 1000 W
Start
Oper.
Total Watts
6.35
9.50
Metal Halide — C.W.A. Ballast Amps — 1000 W
Start
Oper.
Total Watts
1100
8.00
9.20
1080
208
3.80
5.50
1100
4.60
5.30
1080
240
3.20
4.80
1100
4.00
4.60
1080
277
2.75
4.20
1100
3.50
4.00
1080
347
2.80
3.00
1100
2.00
3.20
1080
480
1.80
2.45
1100
2.00
2.30
1080
Luminaire Performance
1000 W
Distribution
Effic.
S./M.H.
High Pressure Sodium
Medium
71.3%
7:1
Wide
74.4%
1.4:1
Medium
76.2%
1.1:1
Wide
75.4%
2.5:1
Metal Halide
1000 W MH Lamps: some manufacturers recommend that their lamps be operated in enclosed units only—select enclosing lens
from list of accessories. Contact your electrical lamp distributor or lamp manufacturer for the latest safety information.
Add suffix -E to catalog number if provision for quartz emergency lamp is desired (lamp not included). Furnished with socket installed and pre-wired.
Supplied complete with C.W.A. Ballast. For 208, 240, 480 or 600 V C.W.I. applications, change the -TT suffix to -C2, -C3, -C6 or -C7 as required. V
C.W.A. is Constant Wattage Autotransformer.
Reflector adjusts for Medium to Wide distribution without tools.
S./M.H.: Spacing to Mounting Height.
V CSA Certification only.
1362
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
Baymaster 1000™ High Bay Luminaires Accessories and Replacement Parts
1000 W HPS; 1000 W MH; 750 W, 1000 W, 1500 W PS-52 Incandescent.
Description
Catalog Number ➊
Wire Guard
Zinc plated.
G-HB-20-NG
1.0"/
25.4 mm
21.0"/
533.4 mm
Hinged Lens — Complete with Socket Schroud
Thermal shock and impact resistant, clear
glass lens.
G-HB-20-NL
Thermal shock and impact resistant,
Corning-73 lens.
G-HB-20-NL3
Aluminum (closes off reflector).
G-HB7000-SS
20.06"/
509.5 mm
Lighting: General Lighting — Area — High Bay
1.0"/
25.4 mm
Socket Shroud
2.25"/
57.2 mm
3.0"/
76.2 mm
2.88"/
73.2 mm
6.0"/
152.4 mm
Safety Cable (not shown)
G-HB7000-SC
Reflector
G-8AW
Supplied with 3 feet of 16/3 SOOW cable
and FHHM-75SS cast safety hook
PWK V
Lighting
Reflector only.
Wiring Kit (not shown)
➊ Other accessories available for 20”/508 mm 1000 W Baymasters include emergency lighting circuits, unit fuses, and special hanger hardware. Contact your
local sales representative.
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
1363
Baymaster 1000™ High Bay Luminaires
Quick Estimate Illumination Charts *
1000 W HPS; 1000 W MH; 750 W, 1000 W, 1500 W PS-52 Incandescent.
1000 Watt Metal Halide
How to use Quick-Estimate Illumination Chart
1. Refer to “Quick-Estimate Illumination Chart” for the lamp type and wattage to be used.
2. Determine “room size” of area to be lighted. “Small Room” is 2500 Sq. Ft. or less. “Medium Room” is 2500 Sq. Ft./232.3 Sq. M. thru
10,000 Sq. Ft./929.0 Sq. M. A “Large Room” is 10,000 Sq. Ft./929.0 Sq. M. or more.
3. Find level of light (footcandles) required in vertical column of figures at left of chart. Then follow horizontal line (real or interpolated) to
right until it intersects with “Arc” of selected “room size.” Come directly down from point of intersection to horizontal line of number
“Square Feet Per Luminaire.” The resulting number (real or interpolated) is the “number of square feet” one Appleton Baymaster will
illuminate to the selected average maintained footcandle level when mounted in conjunction with other units in the high bay installation.
4. Divide number of total square feet in project by “number of square feet per luminaire” to get number of units required.
5. Take square root of resulting “number of square feet per luminaire” number to determine spacing between units.
Lighting
Lighting: General Lighting — Area — High Bay
1000 Watt High Pressure Sodium
* Photometric charts available on request.
1364
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
Lumenmaster 250™ Low Bay HID Prismatic Luminaires
Integrally Ballasted. 150 W, 250 W HPS; 175 W, 200 W, 250 W PSMH, 175 W, 250 W MH V.
Suitable for use in damp locations
Applications
• Energy-efficient, low-glare illumination for manufacturing,
storage and other indoor areas where low bay luminaires are
required. Can be mounted as low as 8 feet/2.4 meters from
work plane.
• Suitable for use in damp locations.
• Operates safely in ambients as high as 104 °F/40 °C.
• Applications involving airborne particulates (such as carbon
black, pigments, etc.) should be pre-evaluated and approved
by Appleton prior to ordering.
Features
Dimensions
/8"/
12-3 mm
314.4
6-1/4"/
158.8 mm
26-3/4"/
679.5 mm
16.0"/
406.4 mm
Standard Materials
•
•
•
•
•
Lighting: General Lighting — Area — Low Bay
• High efficiency (up to 74.6% with 250 W high pressure
sodium lamp) combined with long lamp life, ensures the most
economical operation.
• Two-to-one vertical-to-horizontal footcandles provides effective,
efficient illumination of vertical surfaces.
• Reflector/refractor optical assembly is computer designed for
uniform, wide light distribution with low glare.
• Injection-molded prismatic refractor lens is 100% virgin acrylic.
Minimum thickness is 3/16”/4.8mm.
• Ruggedly built, attractively styled, low-profile design.
• A wide range of ballasts and voltages are available for both
domestic and export applications.
• Integral ballast.
• Capable of starting and operating the lamp in temperatures as
low as -20 °F/-28.9 °C for pulse start metal halide lamps,
-40 °F/-40 °F for high pressure sodium lamps.
• Mogul base socket with spring loaded center contact and heavy
gauge, screw shell with double lamp grips to prevent lamps
from loosening due to vibration.
• Installation is quick and easy:
(1) mount junction box to 3/4”/19.1 mm conduit
(2) slide ballast onto junction box
(3) make connections
(4) install lamp
(5) snap reflector in place
Gasket: silicone rubber
Reflector: aluminum
Ballast housing: finned, coppefree (4/10 of 1% max) aluminum
Sockets: porcelain
Screws: brass
20.0"/
508.0 mm
Standard Finishes
•
•
•
•
Reflector: natural finish
Ballast: white powder coat polyester
Sockets: nickel plated center contact
Screws: nickel plated brass
• Units are available with a pre-wired sensor circuit for
automatically lighting an auxiliary safety lamp in case a power
dip or lamp failure extinguishes the HID lamp.
Related Products
• For power hook, fusing and other suspension accessories see
Fixture Hanger Accessories.
Certifications and Compliances
• UL Listed: E85142
• UL Standard: 1598
• CSA Certified: LR9349
V CSA Certification only.
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
1365
Lighting
Options
Lumenmaster 250™ Low Bay HID Prismatic Luminaires
Integrally Ballasted. 150 W, 250 W HPS; 175 W, 200 W, 250 W PSMH, 175 W, 250 W MH V.
Suitable for use in damp locations
Electrical Specifications
High Pressure Sodium — All ballasts are C.W.A. type, except 150 W HPS which is HX-Auto
Lighting: General Lighting — Area — Low Bay
150 W
250 W
Line Volts
Start
Oper.
Total
Watts
Start
Oper.
Total
Watts
120
2.00
1.70
188
2.00
2.50
295
208
1.15
.95
188
1.20
1.50
295
240
1.00
.85
188
1.00
1.30
295
277
.85
.72
188
.85
1.10
295
347 V
0.52
0.56
188
0.60
0.93
295
480
.50
.47
189
.40
.65
295
Line
Volts
Pulse Start Metal Halide — Super C.W.A. Ballast Amps
175 W
200 W
Total
Total
Start
Oper.
Watts
Start
Oper.
Watts
Start
Oper.
Total
Watts
120
.90
1.78
199
2.10
2.00
235
1.90
2.50
288
208
.50
1.08
199
1.15
1.25
235
1.10
1.45
288
240
.35
.89
199
1.10
1.00
235
.96
1.25
288
277
.30
.76
199
.75
.85
235
.85
1.10
288
347 V
0.25
0.65
199
.25
.70
232
0.62
0.90
288
480
.25
.50
213
.35
.50
237
.46
.60
285
Metal Halide V — C.W.A. Ballast Amps
175 W
Total
Oper.
Watts
250 W
250 W
Start
Oper.
Total
Watts
213
1.2
2.6
295
1.1
213
.65
1.5
295
.90
213
.60
1.3
295
.55
.78
213
.50
1.12
295
0.50
0.65
213
0.80
0.90
295
Line
Volts
Start
120
1.3
1.8
208
.75
240
.65
277
347
Luminaire Performance
150 Watt
S./M.H.
Effic.
Lighting
Distribution
175 Watt
S./M.H.
Effic.
200 Watt
S./M.H.
Effic.
250 Watt
S./M.H.
Effic.
High Pressure Sodium
70.0%
3.2:1
—
—
—
—
74.6%
3.1:1
Pulse Start Metal Halide
—
—
65.9%
2.7:1
53.1%
3.1:1
67.2%
3.0:1
—
—
62.3%
2.6:1
—
—
64.7%
3.0:1
Metal Halide
Reflector adjusts for medium to wide distribution without tools.
S./M.H.: Spacing to Mounting Height.
V CSA Certified only.
1366
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
Lumenmaster 250™ Low Bay HID Prismatic Luminaires
Integrally Ballasted. 150 W, 250 W HPS; 175 W, 200 W, 250 W PSMH, 175 W, 250 W MH V.
Suitable for use in damp locations
Pendant Mounting
Lamp Type
Voltage
Catalog Number
Complete with Reflector/Refractor
Assembly and Ballast
Ballast Housing
Assembly
For High Pressure Sodium Lamps
150 W HPS
120/208/240/277 V
150 W HPS
120/277/347 V
G-LM41AL-MT
G-LM411L-MT
G-LM41AL-TT V④
G-LM411L-TT V④
150 W HPS
480 V
G-LM41AL-48
G-LM411L-48
250 W HPS
120/208/240/277 V
G-LM61AL-MT
G-LM611L-MT
250 W HPS
120/277/347 V
G-LM61AL-TT V④
G-LM611L-TT V④
250 W HPS
480 V
G-LM61AL-48
G-LM611L-48
175 W PSMH
120/208/240/277 V
G-LM51AP-MT
G-LM511P-MT
175 W PSMH
120/277/347 V
G-LM51AP-TT V④
G-LM511P-TT V④
G-LM51AP-48
G-LM511P-48
G-LM201AP-MT
G-LM2011P-MT
For Pulse Start Metal Halide Lamps
480 V
120/208/240/277 V
200 W PSMH
120/277/347 V
G-LM201AP-TT V④
G-LM2011P-TT V④
200 W PSMH
480 V
G-LM201AP-48
G-LM2011P-48
250 W PSMH
120/208/240/277 V
G-LM61AP-MT
G-LM611P-MT
250 W PSMH
120/277/347 V
G-LM61AP-TT V④
G-LM611P-TT V④
250 W PSMH
480 V
G-LM61AP-48
G-LM611P-48
Lighting: General Lighting — Area — Low Bay
175 W PSMH
200 W PSMH
For Metal Halide Lamps V
175 W MH
120/208/240/277 V
G-LM51AH-MT V
G-LM511H-MT V
175 W MH
120/277/347 V
G-LM51AH-TT V④
G-LM511H-TT V④
250 W MH
120/208/240/277 V
G-LM61AH-MT V
G-LM611H-MT V
250 W MH
120/277/347 V
G-LM61AH-TT V④
G-LM611H-TT V④
Lighting
For 150 W HPS fixtures furnished with Instant Hot Restart, add suffix -R to catalog number.
Add Suffix -E to catalog number if provision for quartz emergency lamp is desired (lamp not included). Furnished with socket installed and pre-wired.
To order fixture complete with lamp, add suffix -L to catalog number.
④ Supplied complete with CWA Ballast. For 208, 240, 480 or 600 V CWI applications, change the -TT suffix to -C2, -C3, -C6 or -C7 as required. V
V CSA Certification only.
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
1367
Lumenmaster 250™ Low Bay HID Prismatic Luminaires
Integrally Ballasted. 150 W, 250 W HPS; 175 W, 200 W, 250 W PSMH, 175 W, 250 W MH V.
Accessories and Replacement Parts
Type
Description
Catalog Number
Fuseholder with 9” wire leads
G-F10
Zinc plated.
"/
16 m
5/ m
1- 3.3
3
Safety Cable (not shown)
G-HB7000-SC
Optic Assembly
Optic Assembly only.
G-LM20
Supplied with 3 feet of 16/3 SOOW cable and FHHM-75SS cast safety
hook
PWK V
Lighting
Lighting: General Lighting — Area — Low Bay
Wiring Kit (not shown)
V CSA Certification only.
1368
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
Lumenmaster 250™ Low Bay HID Prismatic Luminaires
Integrally Ballasted. Quick-Estimate Illumination Chart *
Integrally Ballasted. 150 W, 250 W HPS; 175 W, 200 W, 250 W PSMH.
250 Watt High Pressure Sodium
150 Watt High Pressure Sodium
250 Watt Pulse Start Metal Halide
175 Watt Pulse Start Metal Halide
Lighting: General Lighting — Area — Low Bay
How to use Quick-Estimate Illumination Chart
1. Refer to “Quick-Estimate Illumination Chart” for the lamp type and wattage to be used.
2. Determine “room size” of area to be lighted. “Small Room” is 2500 Sq. Ft./232.3 Sq. M. or less. “Medium Room” is 2500 Sq. Ft./232.3
Sq. M. thru 10,000 Sq. Ft./929.0 Sq. M. “Large Room” is 10,000 Sq. Ft./929.0 Sq.M. or more.
3. Find level of light (footcandles) required in vertical column of figures at left of chart. Then follow horizontal line
(real or interpolated) to right until it intersects with “Arc” of selected “room size.” Come directly down from point
of intersection to horizontal line of number “Square Feet Per Luminaire.” The resulting number (real or interpolated) is
the “number of square feet” one Appleton will illuminate to the selected average maintained footcandle level when
mounted in conjunction with other units in the high bay installation.
4. Divide number of total square feet in project by “number of square feet per luminaire” to get number of units required.
5. Take square root of resulting “number of square feet per luminaire” number to determine spacing between units.
Lighting
* Photometric charts available on request. Consult your local sales representative for pulse start metal halide.
V CSA Certification only.
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
1369
Lumenmaster 400™ Low Bay HID Prismatic Luminaires
Integrally Ballasted. 400 W, 250 W HPS; 320 W, 400 W PSMH. 400 W MH V.
Suitable for use in damp locations
Applications
• Energy-efficient, low-glare illumination for manufacturing,
storage and other indoor areas where low bay luminaires are
required. Can be mounted as low as 8 feet/2.4 meters from
work plane.
• Suitable for use in damp locations.
• Operates safely in ambients as high as 104 °F/40 °C
• Applications involving airborne particulates (such as carbon
black, pigments, etc.) should be pre-evaluated and approved by
Appleton prior to ordering.
Lighting: General Lighting — Area — Low Bay
Features
• High efficiency (up to 81.6% with 400 W high pressure
sodium lamp) combined with long lamp life, ensures the most
economical operation.
• Two-to-one vertical-to-horizontal footcandles provides effective,
efficient illumination of vertical surfaces.
• Reflector/refractor optical assembly is computer designed for
uniform, wide light distribution with low glare.
• Injection-molded prismatic refractor lens is 100% virgin acrylic.
Minimum thickness is 3/16”/4.8 mm.
• A wide range of ballasts and voltages are available for both
domestic and export applications.
• Integral ballast.
• Capable of starting and operating the lamp in temperatures as
low as -20 °F/-28.9 °C for pulse start metal halide lamps,
-40 °F/-40 °C for high pressure sodium lamps.
• Mogul base sockets with spring loaded center contact and
heavy gauge screw shell with double lamp grips to prevent
lamps from loosening due to vibration.
• Installation is quick and easy:
(1) mount junction box to 3/4”/4.8 mm conduit
(2) slide ballast onto junction box
(3) make connections
(4) install lamp
(5) snap reflector in place
6.25"/
158.8 mm
12.38"/
314.5 mm
26.0"/660.4 mm
Standard Materials
•
•
•
•
•
15.25"/
387.4 mm
Gasket: silicone rubber
Reflector: aluminum
Ballast: finned, copperfree (4/10 of 1% max.) aluminum
Sockets: heavy duty porcelain
Screws: brass
30.0"/
762.0 mm
Standard Finishes
•
•
•
•
Reflector: natural finish
Ballast: white powder coated polyester
Sockets: nickel plated center contact
Screws: nickel plated
Options
Lighting
Dimensions
• Units are available with a pre-wired sensor circuit for
automatically lighting an auxiliary safety lamp in case a power
dip or lamp failure extinguishes the HID lamp.
Related Products
• For power hook, fusing and other suspension accessories, see
Fixture Hanger Accessories page.
Certifications and Compliances
• UL Listed: E85142
• UL Standard: 1598
• CSA Certified: LR9349
V CSA Certification only.
1370
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
Lumenmaster 400™ Low Bay HID Prismatic Luminaires
Integrally Ballasted. 400 W, 250 W HPS; 320 W, 400 W PSMH. 400 W MH V.
Suitable for use in damp locations
Pendant Mounting
Lamp Type
Voltage
Catalog Number
Complete with Reflector/Refractor
Assembly and Ballast
Ballast Housing
Assembly
For High Pressure Sodium Lamps
250 W HPS
120/208/240/277 V
250 W HPS
120/277/347 V
250 W HPS
480 V
400 W HPS
120/208/240/277 V
400 W HPS
120/277/347 V
400 W HPS
480 V
G-LM61BL-MT
G-LM611L-MT
G-LM61BL-TT V④
G-LM611L-TT V④
G-LM61BL-48
G-LM611L-48
G-LM71BL-MT
G-LM711L-MT
G-LM71BL-TT V④
G-LM711L-TT V④
G-LM71BL-48
G-LM711L-48
G-LM321BP-MT
G-LM3211P-MT
For Pulse Start Metal Halide Lamps
320 W PSMH
120/208/240/277 V
320 W PSMH
120/277/347 V
320 W PSMH
480 V
400 W PSMH
120/208/240/277 V
400 W PSMH
400 W PSMH
G-LM321BP-TT V④
G-LM3211P-TT V④
G-LM321BP-48
G-LM3211P-48
G-LM71BP-TT V④
G-LM711P-MT
120/277/347 V
G-LM71BP-MT
G-LM711P-TT V④
480 V
G-LM71BP-48
G-LM711P-48
400 W MH
120/208/240/277 V
G-LM71BH-MT V
G-LM711H-MT V
400 W MH
120/277/347 V
G-LM71BH-TT V④
G-LM711H-TT V④
Lighting: General Lighting — Area — Low Bay
For Metal Halide Lamps V
Accessories and Replacement Parts
Type
Description
Catalog Number
Fuseholder with 9” wire leads
Zinc plated.
G-F10
"/
16 m
5/ m
1- 3.3
3
Safety Cable (not shown)
G-HB7000-SC
Optic Assembly
G-LM30
Lighting
Optic Assembly only.
Wiring Kit (not shown)
Supplied with 3 feet of 16/3 SOOW cable and FHHM-75SS cast
safety hook
PWK V
To order fixture complete with lamp, add suffix -L to catalog number.
Add Suffix -E to catalog number if provision for quartz emergency lamp is desired (lamp not included). Furnished with socket installed and pre-wired.
For power hook, fusing and other suspension accessories, see Fixture Hanger Accessories.
④ Supplied complete with CWA Ballast. For 208, 240, 480 or 600 V CWI applications, change the -TT suffix to -C2, -C3, -C6 or -C7 as required. V
V CSA Certification only.
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
1371
Lumenmaster 400™ Low Bay HID Prismatic Luminaires
Integrally Ballasted. 400 W, 250 W HPS; 320 W, 400 W PSMH. 400 W MH V.
Suitable for use in damp locations
Electrical Specifications
High Pressure Sodium — All ballasts are C.W.A. type, except 150 W HPS which is HX-Auto
Line Volts
Start
250 W
Oper.
120
2.00
2.50
Total Watts
Start
400 W
Oper.
Total Watts
295
3.30
3.80
465
208
1.20
1.50
295
1.80
2.20
465
240
1.00
1.30
295
1.60
1.90
465
277
.85
1.10
295
1.40
1.70
465
347 V
0.60
0.93
295
1.00
1.32
465
480
.40
.65
295
.80
1.00
465
Pulse Start Metal Halide — Super C.W.A. Ballast Amps
320 W
Start
Oper.
Total Watts
Start
400 W
Oper.
Total Watts
4.00
454
Line
Volts
Lighting: General Lighting — Area — Low Bay
120
2.60
3.25
368
3.50
208
1.50
1.90
368
2.00
2.30
454
240
1.30
1.65
368
1.75
2.00
454
277
1.15
1.40
368
1.50
1.75
454
347 V
0.70
1.10
368
1.10
1.35
454
480
.60
.80
368
.90
1.00
454
Line
Volts
Start
400 W
Oper.
Total Watts
120
3.25
4.0
458
208
1.9
2.3
458
240
1.65
2.0
458
Metal Halide V — C.W.A. Ballast Amps
277
1.4
1.75
458
347
1.20
1.40
458
Luminaire Performance
Lighting
Distribution
Effic.
250 Watt
S./M.H.
Effic.
320 Watt
S./M.H.
Effic.
400 Watt
S./M.H.
High Pressure Sodium
Wide
81.7%
2.0:1
—
—
81.6%
2.0:1
—
—
63.7%
2.3:1
63.2%
2.3:1
—
—
—
—
81.4%
1.7:1
Pulse Start Metal Halide
Wide
Metal Halide V
Wide
V CSA Certified only.
1372
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
Lumenmaster 400™ Low Bay HID Prismatic Luminaires
Integrally Ballasted. Quick Estimate Illumination Charts *
Integrally Ballasted. 400 W, 250 W HPS; 320 W, 400 W PSMH. 400 W MH V.
250 Watt High Pressure Sodium
400 Watt High Pressure Sodium
320 Watt Pulse Start Metal Halide
400 Watt Pulse Start Metal Halide
* Photometric charts available on request. Consult your local sales representative for pulse start metal halide.
Consult your local sales representative for performance with 400 W mercury vapor lamps.
S./M.H.: Spacing to Mounting Height.
V CSA Certified only.
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
1373
Lighting
Candlepower Distribution of 400 W HPS Luminaire — Closed Bottom Acrylic — All data based on clear, mogul base lamp
Fixture Efficiency: 81.6%
Zone
Candlepower
Zone
Candlepower
5
7861
95
667
15
7806
105
328
25
9774
115
184
35
11404
125
82
45
10612
135
32
55
7257
145
20
65
4998
155
0
75
3214
165
0
85
1625
175
0
Lighting: General Lighting — Area — Low Bay
How to use Quick-Estimate Illumination Chart
1. Refer to “Quick-Estimate Illumination Chart” for the lamp type and wattage to be used.
2. Determine “room size” of area to be lighted. “Small Room” is 2500 Sq. Ft./232.3 Sq. M. or less. “Medium Room” is 2500 Sq. Ft./232.3
Sq. M. thru 10,000 Sq. Ft./929.0 Sq. M. “Large Room” is 10,000 Sq. Ft./929.0 Sq. M. or more.
3. Find level of light (footcandles) required in vertical column of figures at left of chart. Then follow horizontal line
(real or interpolated) to right until it intersects with “Arc” of selected “room size.” Come directly down from point
of intersection to horizontal line of number “Square Feet Per Luminaire.” The resulting number (real or interpolated) is
the “number of square feet” one Appleton will illuminate to the selected average maintained footcandle level when
mounted in conjunction with other units in the high bay installation.
4. Divide number of total square feet in project by “number of square feet per luminaire” to get number of units required.
5. Take square root of resulting “number of square feet per luminaire” number to determine spacing between units.
Fixture Hanger Accessories
Baymaster, Lumenmaster, Super-Baymaster
Catalog Number
Voltage
Fits Hubbell Plug No.
Pendant
Feed-Thru
GHPHP Pendant with one 3/4”/19.1 mm hub, GHPHT with two 3/4”/19.1 mm hubs
Furnished with assembled FS box, EFHM safety lock, receptacle and steel cover. Supports 200 lbs/90.7 kgs.
8.50"/
215.9 mm
6.06"/
153.9 mm
120
L5-15P
GHPHP12
GHPHT12
208, 240
L6-15P
GHPHP24
GHPHT24
277
L7-15P
GHPHP27
GHPHT27
480
L8-20P
GHPHP48
GHPHT48
Voltage
Fits Hubbell Receptacle No.
Cord Length
Ft/M
Catalog Number
2/.6
3/.9
4/1.2
2/.6
3.9
4/1.2
2/.6
3/.9
4/1.2
2/.6
3/.9
4/1.2
G-HCPL-2-12
G-HCPL-3-12
G-HCPL-4-12
G-HCPL-2-24
G-HCPL-3-24
G-HCPL-4-24
G-HCPL-2-27
G-HCPL-3-27
G-HCPL-4-27
G-HCPL-2-48
G-HCPL-3-48
G-HCPL-4-48
Catalog Number
Lighting: General Lighting — Area — Low Bay
Matching Cord Sets for above Receptacle Hangers
120
L5-15R
208, 240
L6-15R
277
L7-15R
480
L8-20R
Size
(Inches)
Length (A)
Inch/Millimeters
Support Wt.
Lbs/Kgs
3.88/98.6
4.13/104.9
350/158.8
FHLM-50
FHLM-75
350/158.8
FHLF-75
3.88/98.6
4.13/104.9
200/90.7
FHHM-50
FHHM-75
3.25/82.6
3.25/82.6
200/90.7
FHHF-50
FHHF-75
FH—Hanger Loops With 5/8”/16.0 mm wire opening
FHLM—Male
1/2
3/4
FHLF—Female
1/2
3/4
FHLF-50
3.25/82.6
3.25/82.6
FH—Hanger Hooks With 5/8”/16.0 mm wire opening, 3/8”/19.1 mm jaw opening
FHHM—Male
Lighting
1/2
3/4
FHHF—Female
1/2
3/4
Fuse and Cartridge — Cartridges are furnished complete with two 10”/254 mm-long high temperature wire leads and 600 Volt fuse
1374
6 Amp
G-F6
10 Amp
G-F10
20 Amp
G-F20
30 Amp
G-F30
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
Quartzlite™ 50 Floodlight
300 W thru 500 W quartz tungsten halogen.
Applications
• Recreation — fun after dark with illuminated swimming pools,
basketball, and other court and play areas.
• Beauty — illuminate your home, patio and garden to maximize
the beauty of your home.
• Safety — eliminate night-time hazards with lighting on outdoor
stairways, walkways, and driveways.
• Security — illuminate backyards, entrance ways and other
areas for protection against intruders.
• Saves energy.
Features
• Uses standard household current (120 Volts, 120 Vac).
• Strong, compact, lightweight fixture can be installed
anywhere outdoors.
• Bright anodized aluminum parabolic reflector for efficient
light distribution.
• Lamp held securely in spring-loaded porcelain socket
for positive contact.
• Flowing lines for an attractive appearance blend with
any architectural style.
• Reinforcing rib keeps lens door flat against housing.
• Door hinges cast permanently as part of the housing securely
anchor door, yet entire door can be removed if desired.
• Easy to install 1/2” NPT thread with locknut.
• Attaches to standard electrical box cover plate (not furnished).
Only two wires plus ground to connect.
Dimensions
9.0"/
228.6 mm
7.75"/196.9 mm
2.13"/
54.1 mm
Standard Materials
•
•
•
•
5.63"/143.0 mm
0.5"/12.7 mm
Housing and lens door: single pressure — cast aluminum piece
Lens: heat/shatter resistant glass
Slotted/hex screw:
Adjustable swivel mount
Certifications and Compliances
Description
NEMA Type
Lumens
Max.
Candlepower
Average Max.
Catalog Number
With Lamp
Without Lamp
(Illumination based on use of T-3 Quartz Tungsten Halogen Lamps)
Wide Beam
5x5
6,846
Mounting
Angle
Mounting Height
ft/m
Area Illuminated
Width x Depth
ft/m
8,416
7,685
G-50-5-L120
G-50-5
Mounting
Angle
Mounting Height
ft/m
Area Illuminated
Width x Depth
ft/m
12/3.7
70x70/
21.3x21.3
12/3.7
80x75/
24.4x22.9
16/4.9
80x80/
24.4x24.4
16/4.9
90’x85’
27.4x25.9
20/6.1
100x80/
30.5x24.4
20/6.1
100’x90’
30.5x27.4
Lighting: General Lighting — Area — Floodlights
• UL Listed: E22558
• UL Standard: 1598
• CSA Certified: LR9349
Lighting
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
1375
Quartzlite™ 500/1500 Floodlight
300 W thru 1500 W quartz tungsten halogen lamps.
Applications
• Heavy duty, weatherproof floodlights for industrial, commercial,
and sports applications where efficient, controlled distribution is
required. Widely used for:
— Sports and amusement areas
— Sign lighting
— Parking lots
— Accent lighting
— Security lighting
— Similar applications
Quartzlite™ 500
Projected Area:
1.2 Sq. Ft/0.14 Sq. M
Features
• Choice of mounting fittings and accessories to meet
installation needs.
• Rugged, compact, lightweight design; easy to install and
maintain. Cool operating, long lamp life.
• Quartzlite 500 uses 500 W or 300 W 120 Volts or 130V T-3
quartz tungsten halogen lamps with exceptional efficiency
and economy.
• Quartzlite 1500 uses T-3 quartz tungsten halogen lamps.
Available for use with 1500 W lamps for 208, 220, 240, and 277
Volt operation; for 1250 W lamps, 208 Volt operation; and for
1000 W lamps, 220 or 240 Volts operation.
• 1500 W unit housing has integral fins for maximum heat
dissipation. Hinged door has thermal shock and impact
resistant glass lens.
Dimensions
9.88"/
251 mm
/27
75"
3.1
mm
Lighting: General Lighting — Area — Floodlights
4.5"/
114.3 mm
10.
Lighting
4.75"/
120.7 mm
15.25"/387.4 mm
Standard Materials
• Housing and lens door: rugged, corrosion resistant, one-piece
pressure-cast aluminum
• Hex-head bolts: two 5/16"/8.0 mm
• Thermal shock and impact resistant glass
• Gasket: heavy, one-piece silicone rubber to resist high
temperatures
• Reflector: precision parabolic design, natural finish aluminum
for maximum efficiency
• Swivel mounting arm: heavy duty, degree-marked swivel
mounting arm with 3/4”/19.1 mm pipe thread and locknut
• UL Listed: E22558
• UL Standard: 1598
• CSA Certified: LR9349
Beam Spread
Horizontal
Vertical
2.75"/69.9 mm
Certifications and Compliances
• Housing and hinged lens door: architectural bronze polyester
finish
NEMA Type
11"/279.4 mm
9.5"/
241.3 mm
Standard Finishes
Description
Quartzlite™ 1500
Projected Area:
0.7 Sq. Ft/0.07 Sq. M
Lumens
Candlepower
Average
Maximum
Maximum
Catalog Number
With Lamp
Without
Lamp
(Illumination based on use of T-3 Quartz tungsten Halogen lamps)
Quartzlite™ 1500
Wide Beam
6x6
128.0°
103.0°
23,218
18,689
17,564
Quartzlite 500
Wide
5x5
95°
92°
6,846
8,416
7,685
G-1500L240 ➊
G-1500L277 ➋
G-1500-➌
™
G-500-5-L130 ➍
G-500-5 ➎
➊ Furnished with 1500 W lamps for 240 V line operation.
➋ Furnished with 1500 W lamps for 277 V line operation.
➌ For 1500 W lamps for 208, 220, 240 or 277 V line operation; 1250 W lamps for 208 V line operation; 1000 W lamps for 220 or 240 V line operation.
➍ Furnished with 500 W lamps for 120 or 130 V line operation.
➎ For 300 W or 500 W lamps for 120 or 130 V line operation.
1376
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
Quartzlite™ 500/1500 Floodlight Mounting Fittings and Accessories
300 W thru 1500 W quartz tungsten halogen lamps.
Description
Catalog Number
Crossarm Mount and Wiring Compartment
2.63"/
66.8 mm
1.88"/
47.8 mm
3.0"/
76.2 mm
180° horizontal position scale, mounts with bolt (not furnished).
Aluminum with architectural bronze polyester finish. Includes cord
grip.
G-6028N
Mounts on 1” to 2”/25.4 to 50.8 mm pipe, vertical or horizontal,
or mounts on flat surfaces (used with G-6028N). Includes U-bolts
and bolt for G-6028N. Malleable iron, zinc plated, chromate sealed,
architectural bronze polyester finish.
G-VB101
500 W
GMM4V
500 W
G-506
Extruded aluminum, with slide-off cover. Has six 3/4”/19.1 mm
threaded holes, with three close-up plugs. Mounts five 500 W or
four 1500 W Quartzlites. Mounts on 3/4”/19.1 mm conduit or G-810
poletop fitter.
G-6017
Cast aluminum, for mounting to 1-1/2” or 2”/38.1 to 50.8 mm pip
Has setscrews for securing to pole, 3/4”/19.1mm tapped top hub to
accommodate Quartzlite or Channel Crossarm above. Architectural
bronze polyester finish.
G-810
3.88"/
98.6 mm
Pipe or Wall Mount Bracket
4.0"/
101.6 mm
3.75"/
95.3 mm
4.25"/108.0 mm
Top Visor
5.0"/
127 mm
2.5"/
63.5 mm
8.63"/
219.2 mm
Wire Guard
Channel Crossarm
2.75"/
69.9 mm
2.5"/63.5 mm
Lighting: General Lighting — Area — Floodlights
26.0"/
660.4 mm
Poletop Fitter
3.0"/
76.2 mm
2.25"/
57.2 mm
Replacement Lens Frame Assembly
500 W
G5005RFL
1500 W
G1500RFL
500 W
601252002
1500 W
601252001
Replacement Lens
Lighting
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
1377
Quartzlite™ 500/1500 Floodlights
Quick — Estimate Illumination Table *
300 W thru 1500 W quartz tungsten halogen lamps.
Quartzlite™ 500
Beam Spread
Lighting: General Lighting — Area — Floodlights
Wide
D=10 Feet/3.0 Meters
D=20 Feet/6.1 Meters
B
L
W
X
A
B
L
W
X
A
B
L
W
X
77
44
24/
7.3
19/
5.8
10/
3.0
19
11
48/
14.6
38/
11.6
21/
6.4
5
3
96/
29.3
77/
23.5
42/
12.8
D=80 Feet/24.4 Meters
A
Wide
D=40 Feet Spread/12.2 Meters Spread
A
1.2
D=100 Feet/30.5 Meters
B
L
W
X
.7
192/
58.5
153/
46.6
83/
25.3
A
.8
D=200 Feet/71.0 Meters
B
L
W
X
.4
240/
73.2
190/
57.9
104/
31.7
A
.2
B
L
W
X
.1
481/
146.6
383/
116.7
208/
63.4
Quartzlite™ 500
Beam Spread
Wide
D=10 Feet/3.0 Meters
A
176
D=20 Feet/6.1 Meters
B
L
W
X
74
33/
10.1
24/
7.3
13/
4.0
A
44
D=80 Feet/24.4 Meters
Wide
D=40 Feet Spread/12.2 Meters Spread
B
L
W
X
19
67/
20.4
48/
14.6
25/
7.6
A
11
D=100 Feet/30.5 Meters
B
L
W
X
5
133/
40.5
95/
29.0
51/
15.5
D=200 Feet/71.0 Meters
A
B
L
W
X
A
B
L
W
X
A
B
L
W
X
3
1.2
266/
81.1
191/
58.2
102/
31.1
1.7
0.7
333/
101.5
238/
72.5
127/
38.7
.4
.2
666/
203.0
477/
145.4
255/
77.7
Lighting
Note: To simplify proper beam overlapping, the size of “X” has been determined so that footcandles at edge (B) are approximately 1/3 of center intensity (A).
* Photometric charts available on request.
1378
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
Areamaster Jr.™ HID Wide-Beam Floodlights
Integrally Ballasted. 150 W, 100 W, 70 W, 50 W HPS; 100 W PSMH. Medium Base.
Applications
• Available for use with HPS or PSMH medium base lamps.
• HPS luminaires, with their superior energy efficiency are
excellent for such applications as:
— Security lighting
— Small sports areas
— Parking areas
— Apartment complexes
— Hotels and motels
— Work area lighting
— Accent, building facade and sign lighting
• PSMH luminaires, with their near perfect color rendition, are
recommended for:
— Car lots
— Garden shops
— Small sports areas
— Billboards
— Building facades
— Airports
— Security areas
• HPS and PSMH floodlights replace higher wattage, inefficient
quartz and PAR lighting.
• Suitable for use in wet locations.
Projected Area: 0.7 Sq. Ft.
Features
Standard Materials
• Ballast housing, door and mounting arm: diecast heavy gauge
aluminum
• Reflector: heavy gauge aluminum
• Lens: heat- and impact-resistant tempered glass
• Gasket: heavy, high temperature silicone rubber
Standard Finishes
• Reflector: diffused anodized natural finish
• Housing, lens door and mounting arm: architectural bronze
polyester finish
Certifications and Compliances
• UL Standard: 1598 (supersedes UL Standard 1572).
• Suitable for use in wet locations
• CSA Certified: LR9349
Lighting: General Lighting — Area — Floodlights
• HPS units use approximately 80% less energy than
incandescent PAR-38 lamps and 70-75% less than quartz
lamps. In lumen output, the 50 W HPS unit is comparable to
two 150 W PAR 38 incandescent lamps; 70 W HPS to 300 W
T-3 quartz; and 100 W HPS to 500 W T-3 quartz.
• Beam pattern is NEMA Type 7.
• Extra-compact, high efficiency floodlights designed specifically
for the small size of HID medium base lamps.
• Compact size permits use of existing poles for retrofitting quartz
fixtures.
• Ruggedly built for dependable, vandal-resistant service.
Attractively styled. Easy to install, aim, and service, with easy
access to interior.
• Durable architectural bronze polyester finish resists chipping,
peeling and fading no matter what the weather or climate
conditions.
• Mounting arm: heavy duty, degree-marked swivel mounting arm
with 3/4” pipe thread and locknut. Allows vertical and horizontal
adjustment. Order mounting accessories separately.
• Medium base porcelain socket with nickel-plated contacts.
Rated for 4-KV pulse. Furnished with 392 °F/200 °C leads, prewired to the ballast.
• Reflector: precision parabolic design, natural finish, aluminum
for maximum efficiency.
• Patented hinged door has thermal shock and impact resistant
glass lens, secured within diecast aluminum frame with two
captive stainless hex head steel screws for watertight fit.
• HPF ballasts have non-PCB capacitors.
Lighting
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
1379
Areamaster Jr.™ HID Wide-Beam Floodlights
Integrally Ballasted. 150 W, 100 W, 70 W, 50 W HPS; 100 W PSMH. Medium Base.
Description
Line Voltage
Catalog Number
Pulse Start Metal Halide Fixtures
100 Watt Metal Halide HX-Auto Ballast, High Power Factor
120
G-MM350H-12H ➊➋
50 Watt High Pressure Sodium Reactor Ballast
120
G-MM150L-12R
50 Watt High Pressure Sodium Reactor Ballast, High Power Factor
120
G-MM150L-12RH ➊
70 Watt High Pressure Sodium Reactor Ballast
120
G-MM250L-12R
70 Watt High Pressure Sodium Reactor Ballast, High Power Factor
120
G-MM250L-12RH ➊
100 Watt High Pressure Sodium Reactor Ballast
120
G-MM350L-12R
100 Watt High Pressure Sodium Reactor Ballast, High Power Factor
120
G-MM350L-12RH ➊➋
150 Watt High Pressure Sodium Reactor Ballast
120
G-MM450L-12R
150 Watt High Pressure Sodium Reactor Ballast, High Power Factor
120
G-MM450L-12RH ➊➋
High Pressure Sodium Fixtures
Accessories and Replacement Parts
Lighting
Lighting: General Lighting — Area — Floodlights
Description
Catalog Number
Crossarm Mount
Has wiring compartment, 180° horizontal position scale. Mounts with bolt (not
furnished). Aluminum. Includes cord grip.
G-6028N
Channel Crossarm
Extruded aluminum, with slide-off cover. Six 3/4” threaded holes, with three
close-up plugs. Mounts five luminaires. Mounts on 3/4” conduit or on G-810
poletop fitter.
G-6017
Pipe or Wall Mount Bracket
Mounts on 1” to 2” pipe, vertical or horizontal, or mounts on flat surfaces (used
with G6028N) Includes U-bolts and bolt for G-6028N.
Malleable iron.
G-VB101
Poletop Fitter
Cast aluminum, for mounting to 1-1/2” or 2” pipe. Has setscrews for securing
to pole. 3/4” tapped top hub to accommodate luminaire or Channel Crossarm
above.
G-810
Wire Guard
Mounts to lens door with screws furnished. Zinc plated.
G-506
Top Visor
Aluminum. Easy to install with hardware supplied.
G-MM4V
Vandal Shield
UV stabilized polycarbonate, with installation hardware and instructions.
G-MM-4-VS
Replacement Lens and Frame Assembly
G5005RFL
Replacement Lens Only
59601252002
➊ 208 V, 240 V or 277 V also available. For 208 V, change voltage suffix -12 to -20; for 240 V, change -12 to -24; and for 277 V, change -12 to -27.
➋ For 347 V, change voltage suffix -12H to -34 V.
1380
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
Areamaster Jr.™ HID Wide-Beam Floodlight Specifications
Integrally Ballasted. 150 W, 100 W, 70 W, 50 W HPS; 100 W PSMH. Medium Base.
Line Voltage
Type of Ballast
Starting Amps
Operating Amps
Total Watts
HX-Auto, High Power Factor
1.22/.44
1.15/.50
129
100-Watt Metal Halide
120
150-Watt High Pressure Sodium
120
Reactor
4.50
3.20
170
120
Reactor, High Power Factor
2.20
1.50
170
100-Watt High Pressure Sodium
120
Reactor
3.05
2.10
115
120
Reactor, High Power Factor
1.50
1.05
115
70-Watt High Pressure Sodium
120
Reactor
2.10
1.60
83
120
Reactor, High Power Factor
0.89
0.75
86
120
Reactor
1.80
1.18
62
120
Reactor, High Power Factor
0.95
0.55
60
50-Watt High Pressure Sodium
Dimensions
Channel Crossarm
Pipe/Wall Mount Bracket
Lighting: General Lighting — Area — Floodlights
Crossarm Mount
Poletop Fitter
Lighting
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
1381
Areamaster Jr.™ HID Wide-Beam Floodlight Photometric Data
Integrally Ballasted. 150 W, 100 W, 70 W, 50 W HPS; 100 W PSMH. Medium Base.
Fixture Wattage and HID Lamp—All Medium Base Clear. All Fixtures produce NEMA Type 7 Beam Pattern.
Photometric Data
Horizontal Spread
Beam Lumens
Beam Efficiency
Maximum CP
Average Maximum CP
Total Lumens
Total Efficiency
150 W HPS
146°
10,150
63%
5750
5317
10,422
65%
100 W HPS
146°
6036
64%
3415
3158
6186
65%
70 W HPS
146°
3676
63%
2084
1927
3746
65%
50 W HPS
146°
2536
63%
1437
1328
2576
64%
100 W PSMH
136°
4864
68%
3039
2581
4972
69%
Candlepower Distribution All data based on fixture with clear medium base lamp
100-Watt Metal Halide
0° Candela Table
Angle
Horizontal
-85.5
102
-76.5
175
-67.5
1224
-58.5
1972
-49.5
2319
-40.5
2707
-31.5
3302
-22.5
4091
-13.5
4888
-4.5
5334
0.0
5388
4.5
5334
13.5
4888
22.5
4091
31.5
3302
40.5
2707
49.5
2319
58.8
1972
67.5
1224
76.5
175
85.5
102
Vertical
13
112
450
774
1280
2070
3838
4842
5252
5390
5388
5390
5252
4842
3838
2070
1280
774
450
112
13
0° Candela Table
Angle
Horizontal
-85.5
61
-76.5
104
-67.5
727
-58.5
1171
-49.5
1378
-40.5
1608
-31.5
1961
-22.5
2430
-13.5
2903
-4.5
3168
0.0
3200
4.5
3168
13.5
2903
22.5
2430
31.5
1961
40.5
1608
49.5
1378
58.5
1171
67.5
727
76.5
104
85.5
61
Vertical
8
67
267
459
760
1229
2280
2876
3119
3201
3200
3201
3119
2876
2280
1229
760
459
267
67
8
0° Candela Table
Angle
Horizontal
-76.6
96
-68.0
233
-60.0
415
-52.0
772
-44.0
1471
-36.0
2226
-28.0
2641
-20.0
2729
-12.0
2537
-4.0
2296
0.0
2273
4.0
2296
12.0
2537
20.0
2729
28.0
2641
36.0
2226
44.0
1471
52.0
772
60.0
415
68.0
233
76.0
96
Vertical
11
285
417
536
660
1269
1442
1662
1957
2226
2273
2226
1957
1662
1442
1269
660
536
417
285
11
100-Watt High Pressure Sodium
Lighting
Lighting: General Lighting — Area — Floodlights
150-Watt High Pressure Sodium
1382
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
Beam-Master™ Floodlights
General Purpose and Heavy Duty.
Ballast for 400 W PSMH; 1000 W, 1500 W MH; 400 W, 1000 W HPS.
Applications
•
To illuminate large areas such as:
— Building facades
— Ship loading docks
— Truck terminals
— Security lighting
— Airports
— Athletic stadiums
— Sports fields
Features
Mounting Options
Poletop Slip-Fitter Mounting
Crossarm Mounting
Lighting: General Lighting — Area — Floodlights
• General purpose and heavy duty units available for 400 W
PSMH, 1000 W or 1500 W metal halide lamps or 400 W and
1000 W high pressure sodium lamps. Choice of five different
NEMA beam spreads (1000 W HPS, two beam spreads; 400 W
MH, three beam spreads.)
• Compact design combines reflector assembly and ballast
housing as a single unit — easier to wire and install.
• Balanced weight distribution allows swing-over design for
easy relamping and servicing.
• Sturdy and rugged — withstands high vibration and rugged
usage.
• Breather openings allow unit to breathe, yet keep dirt and
moisture out.
• Floodlights have aiming device, plus 180° vertical positioning
scale. Fully adjustable horizontally with crossarm bracket or
poletop mount.
• Swing-over design with a “memory” locking device for accurate
return to pre-aimed position after servicing.
• Mogul base porcelain socket has heavy gauge brass, nickel
plated, double lamp-grip screw shell and spring-loaded center
contact.
• Heavy duty models have heavy shroud for protection against
severe weather, such as high winds and hail.
• Cord enters through a weatherproof cord grip.
• Yoke is rugged 6061-T6 aluminum alloy. Crossarm bracket and
poletop slip-fitter are malleable iron.
• Ballasts are Class H insulated, UL Listed, C.W.A. type, available
multi-tapped 120, 208, 240, or 277 Volts, or single-tap for 480
Volts.
Standard Materials
•
•
•
•
•
•
Refllectors: aluminum
Lens: shock and impact resistant glass
Gasket: one-piece silicone rubber gasket
Frame and clamps: stainless steel
Socket/ballast: cast aluminum
Housing: mallaeble Iron
Standard Finishes
• Reflectors: natural finish
• Ballast: white powder coated polyester finish
• Housing: zinc plated, chromate sealed, architectural bronze
polyester finish
Certifications and Compliances
• UL Listed: E85142
• UL Standard: 1598
• CSA Certified: LR9349
Lighting
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
1383
Beam-Master™ Floodlights
General Purpose and Heavy Duty.
Ballast for 400 W PSMH; 1000 W, 1500 W MH; 400 W, 1000 W HPS.
Candlepower
NEMA
Beam Spread
Beam
Type
Horiz x Vert.
Lumens Beam Effic. Avg. Max. CP
Max CP
With Ballast for 1000 W Metal Halide Lamp
II
20.2° x 21.1°
37,577
34.2%
1,332,312
1,547,349
III
45.1° x 45.1°
55,104
50.1%
481,977
638,600
IV
58.6° x 59.3°
61,562
56.0%
213,277
266,126
V
73.6° x 74.0°
66,843
60.8%
128,822
160,661
VI
111.5° x 111.2°
74,020
67.3%
76,050
82,363
Line
Voltage
120/208/240/277
Catalog Number
General Purpose
Heavy Duty
G-SM821H-MTN ➊
G-SM821H-48N
G-SM821HH-MTN ➊
G-SM821HH-48N
G-SM831H-MTN ➊
G-SM831H-48N
G-SM831HH-MTN ➊
G-SM831HH-48N
G-SM841H-MTN ➊
G-SM841H-48N
G-SM841HH-MTN ➊
G-SM841HH-48N
G-SM851H-MTN ➊
G-SM851H-48N
G-SM851HH-MTN ➊
G-SM851HH-48N
G-SM861H-MTN ➊
G-SM861H-48N
G-SM861HH-MTN ➊
G-SM861HH-48N
G-SM921H-MTN ➊
G-SM921H-48N
G-SM921HH-MTN ➊
G-SM921HH-48N
G-SM931H-MTN ➊
G-SM931H-48N
G-SM931HH-MTN ➊
G-SM931HH-48N
G-SM941H-MTN ➊
G-SM941H-48N
G-SM941HH-MTN ➊
G-SM941HH-48N
G-SM951H-MTN ➊
G-SM951H-48N
G-SM951HH-MTN ➊
G-SM951HH-48N
G-SM961H-MTN ➊
G-SM961H-48N
G-SM961HH-MTN ➊
G-SM961HH-48N
G-SM721P-MTN ➊
G-SM721P-48N
G-SM721PH-MTN ➊
G-SM721PH-48N
480
G-SM751P-MTN ➊
G-SM751P-48N
G-SM751PH-MTN ➊
G-SM751PH-48N
120/208/240/277
G-SM761P-MTN ➊
G-SM761PH-MTN ➊
120/208/240/277
G-SM851L-MTN ➊
G-SM851L-48N
G-SM851LH-MTN ➊
G-SM851LH-48N
G-SM861L-MTN ➊
G-SM861L-48N
G-SM861LH-MTN ➊
G-SM861LH-48N
G-SM721L-MTN ➊
G-SM721L-48N
G-SM721LH-MTN ➊
G-SM721LH-48N
G-SM731L-MTN ➊
G-SM731L-48N
G-SM731LH-MTN ➊
G-SM731LH-48N
G-SM741L-MTN ➊
G-SM741L-48N
G-SM741LH-MTN ➊
G-SM741LH-48N
G-SM751L-MTN ➊
G-SM751L-48N
G-SM751LH-MTN ➊
G-SM751LH-48N
G-SM761L-MTN ➊
G-SM761L-48N
G-SM761LH-MTN ➊
G-SM761LH-48N
480
120/208/240/277
480
120/208/240/277
480
120/208/240/277
480
120/208/240/277
480
With Ballast for 1500 W Metal Halide Lamp
II
20.2° x 21.1°
52,950
34.2%
1,877,349
2,180,356
III
45.1° x 45.1°
77,646
50.1%
679,149
899,846
IV
58.6° x 59.3°
86,746
56.0%
300,526
374,996
V
73.6° x 74.0°
94,188
60.8%
181,522
226,386
VI
111.5° x 111.2°
104,301
67.3%
107,161
116,057
120/208/240/277
480
120/208/240/277
480
120/208/240/277
480
120/208/240/277
480
120/208/240/277
480
Lighting: General Lighting — Area — Floodlights
With Ballast for 400 W Pulse Start Metal Halide Lamp
II
20.9° x 20.1°
14,538
36.3%
345,368
528,021
V
73.1° x 72.8°
19,566
48.9%
35,090
54,015
VI
108.4° x 99.1°
22,656
66.6%
28,815
34,043
480
120/208/240/277
With Ballast for 1000 W High Pressure Sodium Lamp
V
69.1° x 65.2°
63,710
45.5%
175,347
302,942
VI
110.3° x 104.6°
81,722
58.4%
81,998
107,556
480
120/208/240/277
480
With Ballast for 400 W High Pressure Sodium Lamp
II
III
IV
V
VI
Lighting
120/208/240/277
120/208/240/277
480
120/208/240/277
480
120/208/240/277
480
120/208/240/277
480
120/208/240/277
480
➊ For tri-tap 120/277/347 V, change suffix -MTN to -TTN V.
1384
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
Beam-Master™ Floodlights
General Purpose and Heavy Duty.
Ballast for 400 W PSMH; 1000 W, 1500 W MH; 400 W, 1000 W HPS.
Mounting Fittings and Accessories
Dimensions
Dimensions
Description
Catalog Number
Crossarm Mounting Bracket
5.0"/
127.0 mm
4.44"/
112.8 mm
G-AM-8-CA
Slip-fits 2” or 2-1/2”/50.8 or 63.5 mm
poletop tenons. Includes floodlight yoke
bolts, 3 locking bolts and cord grip.
G-AM-8-SF
22.88"/581.2 mm
2.31"/
58.7 mm
24.00"/609.6 mm
21.00"/533.4 mm
180° horizontal adjustment—
degree-marked. Facilitates mounting
floodlight to crossarm or other flat
surface, or to G-AM-8-WB. Includes
floodlight yoke bolts.
Poletop Slip-Fitter
3.5"/
88.9 mm
4.5"/
114.3 mm
6.0"/127.0 mm
4.0"/101.6 mm
Pipe or Wall Mount Bracket
4.88"/
124.0 mm
5.0"/
127.0 mm
3.0"/
76.2 mm
5.5"/139.7 mm
4.5"/
114.3 mm
Used with G-AM-8-CA. Clamps to 1”
to 2”/25.4 to 50.8 mm pipe, vertical or
horizontal, or mounts on flat surfaces.
Includes U-bolt and crossarm bracket
bolts.
G-AM-8-WB
Fuse and Cartridge
10 Amp.
G-F10
20 Amp
G-F20
Electrical Specifications
400 W
Line
Volts
Start
Oper.
Metal Halide — C.W.A. ➋ Ballast Amps
1000 W
Total
Total
Watts
Start
Oper.
Watts
Start
1500 W
Oper.
Total
Watts
High Pressure Sodium — C.W.A. ➋ Ballast Amps
400 W
1000 W
Total
Total
Start
Oper.
Watts
Start
Oper.
Watts
120
3.25
4.00
458
8.0
9.20
1080
13.50
14.0
1610
3.30
3.80
465
6.35
9.50
1100
208
1.90
2.30
458
4.6
5.30
1080
7.70
8.00
1610
1.80
2.20
465
3.80
5.50
1100
240
1.90
2.00
458
4.0
4.60
1080
6.70
7.00
1610
1.60
1.90
465
3.20
4.80
1100
277
1.40
1.75
458
3.50
4.00
1080
5.90
6.00
1610
1.40
1.70
465
2.75
4.20
1100
480
.85
1.00
465
2.00
2.30
1080
2.25
3.50
1610
.80
1.00
465
1.80
2.45
1100
Lighting
➋ C.W.A.—Constant Wattage Autotransformer.
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
Lighting: General Lighting — Area — Floodlights
Cartridges are furnished complete with
two 10”/254 mm-long high temperature
wire leads and 600 Volt fuse.
1385
Wallmaster™ HPS/PSMH Luminaires
Lighting: General Lighting — Area — Architectural
Lighting
Vertical and Horizontal Wall Mount
50 W, 75 W, 100 W, 150 W HPS; 70 W, 100 W PSMH.
Applications
• Totally enclosed luminaires for public security installations.
Tough polycarbonate refractor provides vandal resistance.
• Ideal where illumination over wide areas adjacent to walls
is required. Applications include walkways, parking lots
and garages, building exteriors, shopping centers, stores,
restaurants, tunnels, underpasses, loading docks, ramps,
security lighting areas, entrances and recreational areas.
Features
• Computer designed optical system. Reflector provides optimum
down and out light distribution. Prismatic refractor provides soft
light with even distribution, reducing glare.
• Contemporary architectural design with attractive bronze
polyester finish. Soft, diffused light enhances the beauty of any
architectural setting.
• Enclosed and gasketed for use in wet locations—indoors and
out. High temperature neoprene gasketing.
• Easy to maintain. Hinged lens frame swings open (just loosen
two captive bolts) for fast, easy relamping and access to
internal components.
• Quick, easy installation. Fixture bolts to any flat surface or
any standard 3” or 4”/76.2 or 101.6 mm outlet box for vertical
mounting.
• High energy efficiency. High pressure sodium lamps use
approximately one-fourth as much electrical energy as
incandescent lamps.
• Pre-wired, integrally ballasted.
• Complete assemblies available with a choice of ballasts: high
reactance high power factor—with or without photocontrol
(automatic ON–OFF operation). High power factor ballasts
provide a minimum 90% P.F. and are suitable for use in high
ambient temperature areas. High reactance high power factor
ballasts are single-tap (120 or 480 Vac), dual tap (120/277 Vac)
and multi-tap (120-277 Vac). Reactor and reactor high power
factor ballasts are 120 Vac.
• Glass thermal barrier in 100 W and 150 W units protects
polycarbonate lens from heat for longer lens life.
• Tough, molded polycarbonate refractor provides cool fixture
operation.
• Three knockouts provided for conduit and wiring.
• Medium base porcelain socket with spring loaded nickel plated
contacts.
Standard Materials
• Ballast housing and wall bracket: aluminum
• Hinged lens assembly: high Impact, non-solarizing,
polycarbonate
• Reflector: aluminum
Dimensions
18.0"/
457.2 mm
9.81"/
249.2 mm
4.88"/
124.0 mm
6.38"/
162.1 mm
15.13"/
384.3 mm
.49 Sq.Ft./0.05 Sq. M
.51 Sq.Ft./0.05 Sq. M
2.88"/
73.2 mm
6.88"/
174.8 mm
Certifications and Compliances
• UL Standard: E85142
• UL Standard: 1598
• CSA Certified: LR9349
Standard Finishes
• Ballast housing, wall bracket: two-coat bronze polyester finish
• Reflector: natural finish
Options
• Photocontrol provides automatic ON-OFF operation. Order
luminaires with -PC suffix or add -PC suffix to any 120 Volt
luminaire catalog numbers.
† For multi-tap ballast specify voltage to be used.
1386
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
Wallmaster™ HPS/PSMH Luminaires
Vertical and Horizontal Wall Mount
Line Voltage
Vertical Mount
Catalog Number
Horizontal Mount
Vertical Mount V
50-Watt High Pressure Sodium
Reactor Ballast
120 V
G-WM130L-12R
G-WM134L-12R
G-WMM50L-R1 V
Reactor Ballast, High Power Factor
120 V
G-WM130L-12RH
G-WM134L-12RH
G-WMM50L-H1 V
70-Watt High Pressure Sodium
High Reactance Ballast, High Power Factor
120/208/240/277 V
G-WM230L-MT
G-WM234L-MT
G-WMM70L-MT V
High Reactance Ballast, High Power Factor
480 V
G-WM230L-48
G-WM234L-48
Not Available
Reactor Ballast
120 V
G-WM230L-12R
G-WM234L-12R
G-WMM70L-R1 V
Reactor Ballast, High Power Factor
120 V
G-WM230L-12RH
G-WM234L-12RH
G-WMM70L-H1 V
100-Watt High Pressure Sodium
High Reactance Ballast, High Power Factor
120/208/240/277 V
G-WM330L-MT
G-WM334L-MT
G-WMM10L-MT V
High Reactance Ballast, High Power Factor
480 V
G-WM330L-48
G-WM334L-48
Not Available
Reactor Ballast
120 V
G-WM330L-12R
G-WM334L-12R
G-WMM10L-R1 V
Reactor Ballast, High Power Factor
120 V
G-WM330L-12RH
G-WM334L-12RH
G-WMM10L-H1 V
G-WM430L-MT
G-WM434L-MT
Not Available
150-Watt High Pressure Sodium
High Reactance Ballast, High Power Factor
120/208/240/277 V
High Reactance Ballast, High Power Factor
480 V
Not Available
Not Available
Not Available
Reactor Ballast
120 V
G-WM430L-12R
G-WM434L-12R
G-WMM15L-R1 V
Reactor Ballast, High Power Factor
120 V
G-WM430L-12RH
G-WM434L-12RH
G-WMM15L-H1 V
120/208/240/277 V
G-WM230H-MT
G-WM234H-MT
G-WMM70H-MT V
120/208/240/277 V
G-WM330H-MT
G-WM334H-MT
G-WMM10H-MT V
70-Watt Pulse Start Metal Halide
High Reactance Ballast, High Power Factor
100-Watt Pulse Start Metal Halide
High Reactance Ballast, High Power Factor
Wall Mounting Kit
Dimensions
Description
Catalog Number
4.88"/
124.0 mm
Adapts vertical mount fixtures to horizontal
position.
G-WM-HMK
2.88"/
73.2 mm
Add suffix -PC for Photocontrol. Provides automatic dusk-to-dawn ON-OFF operation. Specify voltage to be used with photocell, if used with multi voltage
ballast.
Change the -MT suffix to -TT for tri-tap 120/277/347 V V.
V CSA Certification only.
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
1387
Lighting: General Lighting — Area — Architectural
Description
Lighting
50 W, 75 W, 100 W, 150 W HPS; 70 W, 100 W PSMH.
Wallmaster™ HPS/PSMH Luminaire Electrical Specifications
Lighting: General Lighting — Area — Architectural
Lighting
Vertical and Horizontal Wall Mount
50 W, 75 W, 100 W, 150 W HPS; 70 W, 100 W PSMH.
Line Voltage
Type of Ballast
Starting Amps
Operating Amps
Total Watts
50-Watt High Pressure Sodium
120
Reactor
1.80
1.18
60
120
Reactor, High Power Factor
0.75
0.55
60
70-Watt High Pressure Sodium
120/208/240/277
High Reactance, High Power Factor
0.75/0.35
0.81/0.35
91
480
High Reactance, High Power Factor
0.21
0.21
94
120
Reactor
2.25
1.70
87
120
Reactor, High Power Factor
0.85
0.75
82
100-Watt High Pressure Sodium
120/208/240/277
High Reactance, High Power Factor
1.30/.60
1.15/0.50
130
480
High Reactance, High Power Factor
0.33
0.31
135
120
Reactor
3.05
2.40
115
120
Reactor, High Power Factor
1.50
1.05
115
High Reactance, High Power Factor
2.00/0.85
1.65/.72
188
150-Watt High Pressure Sodium
120/208/240/277
480
High Reactance, High Power Factor
0.50
0.47
189
120
Reactor
4.55
3.40
170
120
Reactor, High Power Factor
2.20
1.50
170
0.80/0.39
0.85/0.39
95
1.22/0.44
1.15/0.50
128
70-Watt Pulse Start Metal Halide
120/208/240/277
High Reactance, High Power Factor
100-Watt Pulse Start Metal Halide
120/208/240/277
1388
Constant Wattage Auto transformer (CWA)
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
Wallmaster™ HPS/PSMH Luminaire Photometric Data *
Vertical and Horizontal Wall Mount
Lighting
50 W, 75 W, 100 W, 150 W HPS; 70 W, 100 W PSMH. Data Based on 70 Watt, HPS Clear B-17 Medium Base Lamp (6,300 lumens).
Lighting: General Lighting — Area — Architectural
Typical Footcandle Values
70 W High Pressure Sodium
Ft. Candles for Iso-Footcandle Lines
Mtg. Ht.
A
B
C
E
F
6'
5.80
4.80
3.87
2.88
D
1.94
0.96
0.39
G
7'
4.22
3.54
2.84
2.14
1.42
0.70
0.29
8'
3.26
2.72
2.17
1.63
1.09
0.54
0.22
10'
2.09
1.73
1.39
1.04
0.70
0.34
0.14
12'
1.45
1.21
0.96
0.72
0.48
0.24
0.10
14'
1.06
0.89
0.71
0.53
0.36
0.18
0.07
Watts
Lumens
Mult.
35
2,250
.357
50
3,500
.556
100
9,500
1.508
150
16,000
2.540
NOTE: For other HPS, Clear, Med. Base Lamps multiply
all footcandle values as follows:
◊ Distance in terms of mounting height (i.e., ratio) of distance to height. Example: @ 15 foot/4.6 meters mounting height, 1 means 15 foot/4.6 meters; 2 means
30 foot/9.1 meters, etc.)
* Additional photometric charts available on request.
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
1389
Wallmaster 400 HPS/PSMH Luminaires
™
Lighting: General Lighting — Area — Architectural
Lighting
Horizontal Lamps Suitable for Wet Locations
400 W, 250 W, 175 W PSMH; 400 W, 250 W HPS. Mogul Base.
Applications
• Ideal where illumination over wide areas adjacent to walls is
required. Applications include:
— Walkways
— Parking lots
— Garages
— Building exteriors
— Shopping centers
— Stores
— Restaurants
— Tunnels
— Underpasses
— Loading docks
— Ramps
— Security lighting areas
— Entrances
— Recreational areas
Features
• Enclosed and gasketed for use in outdoor wet locations.
• Specular anodized aluminum reflector provides efficient light
projection.
• High transmittance, non-yellowing borosilicate glass refractor
for superior photometrics.
• Field adjustable bracket permits easy adjustment of beam
angle.
• Quick, easy installation. Back plates permit alignment with
virtually all standard recessed junction boxes.
• Prewired, integrally ballasted. Housing is designed for heavy
duty use and coated with bronze polyester powder to optimize
protection against chipping and fading.
• Stainless steel aircraft cable connects lens assembly to
mounting plate freeing both hands for servicing and installation.
• 3 tapped holes (1/2”/12.7 mm NPS standard) – one on each
side and one on the top. May be used for conduit or optional
photocontrol.
• All ballasts are high power factor, CWA type.
Standard Materials
• Ballast housing: die cast copperfree (4/10 of 1% max.)
aluminum
• Refractor: heat and shock resistant, non-yellowing borosilicate
glass
• Refractor to housing joint: liquid silicone rubber
• Gasket (between lens assembly and mounting plate): neoprene
• Lamp socket: glazed porcelain
Standard Finishes
• Ballast housing: bronze polyester finish
Options
•
•
•
•
Stainless steel wire guard to protect fixture.
Lexan® shields for added protection.
Photocontrol for automatic ON/OFF operation.
Fusing to provide overcurrent protection.
Certifications and Compliances
• UL Listed: E85142
• UL Standard:1598
• CSA Certified: LR9349
1390
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
Wallmaster 400 HPS/PSMH Luminaires
™
Horizontal Lamps Suitable for Wet Locations
Lighting
400 W, 250 W, 175 W PSMH; 400 W, 250 W HPS. Mogul Base.
Weight Lbs./
Kgs ➊
Catalog
Number
175 Watt Metal Halide
CWA Ballast, High Power Factor
120-277
17/7.7
G-WM530P-MT ➋
CWA Ballast, High Power Factor
480
17/7.7
G-WM530P-48 ➋
CWA Ballast, High Power Factor
120-277
24/10.9
G-WM630P-MT ➋
CWA Ballast, High Power Factor
480
24/10.9
G-WM630P-48 ➋
CWA Ballast, High Power Factor
120-277
38/17.2
G-WM730P-MT ➋
CWA Ballast, High Power Factor
480
38/17.2
G-WM730P-48 ➋
CWA Ballast, High Power Factor
120-277
41/18.6
G-WM630L-MT ➋
CWA Ballast, High Power Factor
480
41/18.6
G-WM630L-48 ➋
CWA Ballast, High Power Factor
120-277
45/20.4
G-WM730L-MT ➋
CWA Ballast, High Power Factor
480
45/20.4
G-WM730L-48 ➋
250 Watt Pulse Start Metal Halide
400 Watt Pulse Start Metal Halide
250 Watt High Pressure Sodium
400 Watt High Pressure Sodium
Dimensions
MH
12.25"/
12-1/4"
311.2 mm
PSMH, HS
7.25"/
7-1/4"
184.2 mm
9.5"/
9-1/2"
241.3
mm
17.0"/
431.8 mm
14.0"/
355.6 mm
9.5"/
241.3 mm
➊ All weights are approximate.
➋ Use supply wire rated 302 °F/150 °C.
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
1391
Lighting: General Lighting — Area — Architectural
Line
Voltage
Description
Wallmaster 400 HPS/PSMH Luminaire Accessories
™
Lighting: General Lighting — Area — Architectural
Lighting
Horizontal Lamps Suitable for Wet Locations
400 W, 250 W, 175 W PSMH; 400 W, 250 W HPS. Mogul Base.
Description
Weight Lbs./Kgs ➊
Catalog Number
0.1/.05
G-FH2
Fuse Kit
2 Amp
3 Amp
0.1/.05
G-FH3
5 Amp
0.1/.05
G-FH5
6 Amp
0.1/.05
G-FH6
8 Amp
0.1/.05
G-FH8
10 Amp
0.1/.05
G-FH10
For use with 175 Watt Metal Halide
1.2/0.54
G-WM5G
For use with 250 – 400 Watt Metal Halide
and High Pressure Sodium
1.3/0.59
G-WM7G
Stainless Steel Guard
Lexan® Shield
For use with 175 Watt Metal Halide
1.0/0.45
G-WM5VS
For use with 250 – 400 Watt Metal Halide
and High Pressure Sodium
1.5/0.68
G-WM7VS
120 Volt (1900 VA)
0.3/0.14
G-WMPC120
208-277 Volt (1900 VA)
0.3/0.14
G-WMPC208
480 Volt (1900 VA)
0.3/0.14
G-WMPC480
Lens / Cover Assembly for 175 Watt Units
6.5/2.95
G-WM5CA
Lens / Cover Assembly for 250 – 400 Watt Units
11.3/5.13
G-WM7CA
Mogul Base Lampholder
0.5/0.23
G-WMRS
Photocontrols
Replacement Parts
➊ All weights are approximate
1392
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
Wallmaster 400 HPS/PSMH Luminaire Photometric Data
™
Horizontal Lamps Suitable for Wet Locations
Lumens:
Mounting Height:
400 Watt Pulse Start Metal Halide
Clear, BT-37
34000
20 Feet
RATIO: LATERAL DISTANCE / MOUNTING HEIGHT
0
5
1
400 Watt Metal Halide
2
2
CONVERSION TABLE
for different mounting heights
15’
1.78
30’
.44
20’
1.00
35’
.33
25’
.64
40’
.25
G-WM630P
Lumens:
Mounting Height:
3
.2
4
250 Watt Pulse Start Metal Halide
Clear, BT-28
19500
15 Feet
3
2
1
0
1
2
3
RATIO: LATERAL DISTANCE / MOUNTING HEIGHT
0
5
1
2
CONVERSION TABLE
for different mounting heights
1
2
10’
2.25
20’
.56
15’
1.00
25’
.36
.5
3
.2
4
G-WM530P
Lamp:
2
1
1
16’
.39
10’
1.00
18’
.30
3
12’
.83
20’
.25
4
14’
.51
2
1
.5
.25
5
2
3
400 Watt High Pressure Sodium
Clear, E18
50000
20 Feet
1
.44
20’
1.00
35’
.33
25’
.64
40’
.25
0
1
1
2
10
5
1
2
2
1
3
3
4
2
5
.5
.5
4
.25
.2
5
5
3
3
2
2
1
1
0
1
0
2
1
RATIO: LONGITUDINAL DISTANCE / MTG. HGT.
30’
RATIO: LONGITUDINAL DISTANCE / MTG. HGT.
1.78
3
2
1
0
1
RATIO: LATERAL
DISTANCE
/ MOUNTING
RATIO: LATERAL
DISTANCE
/ MOUNTING
HEIGHT HEIGHT
0
CONVERSION TABLE
for different mounting heights
15’
3
5
2
1.56
Lumens:
Mounting Height:
2
0
8’
Lamp:
1
1
CONVERSION TABLE
for different mounting heights
G-WM730L
0
RATIO: LATERAL DISTANCE / MOUNTING HEIGHT
RATIO: LONGITUDINAL DISTANCE / MTG. HGT.
Lumens:
Mounting Height:
3
175 Watt Pulse Start Metal Halide
Coated, BT-28
(in middle position)
12000
10 Feet
RATIO: LONGITUDINAL DISTANCE / MTG. HGT.
Lamp:
1
.5
RATIO: LONGITUDINAL DISTANCE / MTG. HGT.
Lamp:
Lighting: General Lighting — Area — Architectural
G-WM730P
Lighting
400 W, 250 W, 175 W PSMH; 400 W, 250 W HPS. Mogul Base.
3
2
3
1393
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
RATIO: LATERAL DISTANCE / MOUNTING HEIGHT
0
RAT
Wallmaster 400 HPS/MH Luminaires Photometric Data
™
400 W, 250 W, 175 W PSMH; 400 W, 250 W HPS. Mogul Base.
G-WM630L
Lamp:
Lumens:
Mounting Height:
250 Watt High
Pressure Sodium
Clear, E-18
27500
20 Feet
RATIO: LATERAL DISTANCE / MOUNTING HEIGHT
0
5
1
2
2
1
.5
3
.2
4
3
2
1
0
1
2
3
Fusing For Wallmaster™ 400
Lamp Watts
175 W
250 W
400 W
1394
Volts
120
208
240
277
480
120
208
240
277
480
120
208
240
277
480
1
Ballast Amps
High Pressure Sodium (CWA)
Pulse Start Metal Halide (CWA)
Rating
Start
Oper.
Rating
Start
Oper. 2
—
—
—
5A
.90
1.78
—
—
—
3A
.50
1.08 3
—
—
—
3A
.35
.89
—
—
—
2A
.30
.76 4
—
—
—
2A
.25
.50
8A
2.00
2.50
8A
1.90
2.50
5A
1.20
1.50
5A
1.10
1.45
5A
1.00
1.30
5A
.96
1.25
3A
.85
1.10
3A
.85
1.10
3A
.40
.65
3A
.45
.60
10A
3.30
3.80
10A
3.50
4.00
8A
1.80
2.20
6A
2.00
2.30
5A
1.60
1.90
5A
1.75
2.00
5A
1.40
1.70
5A
1.50
1.75
5A
.80
1.00
5A
.90
1.00
5
Fuse Catalog Number
3
Fuse
Qty. Req.
1
2
2
1
2
2 1
1
2
2
1
2
1
2
2
1
2
2
HPS
(CWA)
—
.5
—
—
.2
—
0
1
—
G-FH8
G-FH5
G-FH5
G-FH3
G-FH3
G-FH10
G-FH8
G-FH5
G-FH5
G-FH5
1
2
3
RATIO: LONGITUDINAL DISTANCE / MTG. HGT.
RATIO: LATERAL DISTANCE / MOUNTING HEIGHT
0
RATIO: LONGITUDINAL DISTANCE / MTG. HGT.
Lighting: General Lighting — Area — Architectural
Lighting
Horizontal Lamps Suitable for Wet Locations
PSMH
(CWA)
G-FH5
G-FH3
G-FH3
G-FH2
G-FH2
G-FH8
G-FH5
G-FH5
G-FH3
G-FH3
G-FH10
G-FH6
G-FH5
G-FH5
G-FH5
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
Areamaster Squarelite™ 400 Sharp Cutoff Luminaires
Integrally Ballasted. For Double-Ended, Tubular 400 W HPS.
Lighting
Lighting: General Lighting — Area — Architectural
Applications
• Powerful, efficient lighting for areas such as parking lots,
shopping centers, building exteriors, sports areas, security
lighting and industrial process lighting.
• Ideal where controlled light distribution over medium or large
size areas is required. Delivers light only where it is needed with
virtually no glare.
• Enclosed and gasketed, Suitable for use in wet locations.
Features
• A single luminaire efficiently projects light in a rectangular
pattern-the shape of most areas to be lighted. A cluster of four
pole-mounted luminaires casts light in a nearly perfect square.
Ideal for such areas as parking lots, shopping centers and
sports areas.
• Utilizes a specially developed, small, double-ended tubular
lamp in combination with a unique precision reflector. The
design of the reflector together with the precise positioning of
the arc tube provides exceptionally accurate control of the light
distribution.
• Projects optimum light levels over medium and large size areas
with virtually no wasted light. A single, horizontally mounted 400
Watt luminaire provides 36,350 candlepower at 51 with a sharp
cutoff at 66° (62° at front and 4° at back of luminaire) with a
horizontal cutoff (sideways ) at 101°.
• Sharp cutoff confines light to specific property zones No spilling
of light on neighboring properties.
• Even light distribution at a 4-to-1 spacing-to-pole-height ratio.
• Virtually no glare. The lamp is deeply recessed within the
reflector to eliminate visually uncomfortable glare.
• Compact in size, attractively styled contemporary design,
rugged and dependable.
• A wide range of ballasts and voltages are available for both
domestic and export applications.
• Integral ballast.
• Mounting Choice:
(1) Trunnion mount, zinc plated steel trunnion with architectural
bronze polyester finish
(2) Integral slip-fitter mount. Built-in slip-fitter for internal wiring.
Adjustable laterally and vertically, slip-fits 2” or 2-1/2”/50.8 or
63.5 mm pipe. Architectural bronze polyester finish
(3) Davit Mount. Bolts to square pole-topfitter. Up to four
luminaries may be clustered on each pole fitter
Illustrated Features
Unique reflector design projects light at wide angle with sharp cutoff.
Projected Area: 1.2 Sq. Ft./0.11 Sq. M.
Standard Materials
•
•
•
•
•
•
Reflector: aluminum
Lens: thermal shock and impact resistant glass
Gasket: silicone rubber
Housing: aluminum
Lens door: aluminum
Hex head bolts: 4 — 1/4"/6.4 mm dia. captive stainless steel
Standard Finishes
• Reflector: natural finish
• Housing, mounting and lens door: architectural bronze polyester
finish
Certifications and Compliances
• UL Listed: E85142
• UL Standard: 1598
• CSA Certified: LR9349
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
With Areamaster Squarelite, a single horizontally mounted
(for low glare) luminaire projects light at a wide angle with sharp
cutoff-ideal for medium and large size areas such as
parking lots, shopping centers and sports areas.
Electrical Specifications
Line Volts
120
208
240
277
347
480
High Pressure Sodium — C.W.A. Ballast Amps — 400 W
Start
Oper.
Total Watts
3.30
3.80
465
1.80
2.20
465
1.60
1.90
465
1.40
1.70
465
1.00
1.32
465
0.80
1.00
465
1395
Areamaster Squarelite™ 400 Sharp Cutoff Luminaires
Lighting: General Lighting — Area — Architectural
Lighting
Integrally Ballasted. For Double-Ended, Tubular 400 W HPS.
Description
LIne Voltage
Catalog Number ➊
Davit Mount
120/208/240/277
Bolts to Square Poletop Filter
(Cat No. G-SCDA) or Wall
Bracket (Cat. No. G-SWD-1
below.
G-SC776L-MT-L ➋
480
G-SC776L-48-L
120/208/240/277
G-SC776L-MT ➋
480
G-SC776L-48
Integral Slip-Fitter Mount
120/208/240/277
Slip-fits on any 2”/50.8 mm or
2-1/2”/63.5 mm pipe size poletop
tenons.
G-SC775L-MT-L ➋
480
G-SC775L-48-L
120/208/240/277
G-SC775L-MT ➋
480
G-SC775L-48
Trunnion Mount
120/208/240/277
May be used with Poletop
slip-fitter or crossarm accessory
G-SC771L-MT-L ➋
480
G-SC771L-48-L
120/208/240/277
G-SC771L-MT ➋
480
G-SC771L-48
Square Poletop Fitter for Davit Mount
Slips onto 2”/50.8 mm poletop tenons.
Accommodates up to four Davit Mount
luminaires.
G-SCDA
Secured to wall with four bolts.
Davit mount is bolted to this bracket.
G-SWD-1
UV stabilized polycarbonate, with installation
hardware and instructions.
G-AM-6-VS
For NEMA type photocontrol, with installation
hardware, instructions.
G-1PCR
Wall Bracket for Davit Mount
Vandal Shield for Luminaire
Photocontrol Receptacle
➊ Lamp furnished with fixture on catalog numbers with Suffix -L: HPS tubular 400 W T-7, 46,000 lumens (LU400/T7).
➋ Change the -MT suffix to -TT for tri-tap 120/277/347 V V.
1396
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
Areamaster Squarelite™ 400 Sharp Pole Data
Integrally Ballasted. For Double-Ended, Tubular 400 W HPS.
Lighting
Lighting: General Lighting — Area — Architectural
Application
• To mount single or multiple luminaires at heights of 20 to 40
feet/ 6.1 to 12.2 meters.
4.0"/
101.6 mm
Features
T
4.0"/
101.6 mm
• 2”/50.8 mm pipe size tenon accepts a single luminaire, or 2, 3
or 4 luminaires with appropriate poletop bracket.
• High-strength shafts are made from square steel structural tube
with minimum yield strength of 46,000 psi.
• Base plates are of structural quality hot-rolled steel with
minimum yield strength of 36,000 psi. Anchor base telescopes
the pole shaft and is welded around top and bottom.
• A 3” x 5”/76.2 x 127 mm reinforced handhole with cover and
grounding lug 14”/355.6 mm above the pole base is standard.
• Anchor bolts are furnished complete with two hex nuts and
washers, and are of 55,000 psi steel.
• Poles are designed to withstand dead loads and theoretical
dynamic loads developed by sustained winds of 80 mph/128
kph with an appropriate gust factor. The weights and EPA
include luminaires and/or mounting adapters, and their effective
projected area is considered to be the product of
the actual projected area and the drag coefficient. Pennants,
signs, and similar elements that create additional stress on
poles should not be used without prior factory approval.
2”/50.8 mm
Pipe Size Tenon
(2-3/8”/
60.5 mm O.D.)
14.0"/
355.6 mm
Square Steel Poles for Davit Mount Luminaires
Dimensions may vary. Consult your local sales representative for specifications
Mtg. Ht.
Feet/Meters
A
Shaft Size
Inches/ Millimeters
Bolt Circle
in/mm
BC
Base Thickness
in/mm
T
Anchor Bolt
Dia. x Lgth.
in/mm
Max. Proj.
Area
Sq.Ft./Sq.M. ➊
Catalog Number ➌
20/6.1
4” x 4” x 11Ga./
101.6 x 101.6 x 11Ga
➋
.75/19.1
.75 x 20/
19.1 x 508
9.0/0.84
G-PSSL-20EPX
25/7.6
4” x 4” x 11Ga.
101.6 x 101.6 x 11Ga.
➋
.75/19.1
.75 x 20/
19.1 x 508
4.1/0.38
G-PSSL-25EPX
30/9.1
5” x 5” x 11Ga.
127 x 127x 11Ga
➋
1.0/25.4
.25 x 20/
25.4 x 508
4.2/0.39
G-PSSL-30EPX
35/10.7
5” x 5” x 7Ga.
127 x 127 x 7Ga
➋
1.0/25.4
1 x 40/
25.4 x 1016
6.1/0.57
G-PSSM-35EPX
39/11.9
6” x 6” x 7Ga.
152.4 x 152.4 x 7Ga.
➋
1.0/25.4
1 x 40
25.4 x 1016
7.8/0.72
G-PSSH-39EPX
➊ Calculated for winds of 80 MPH/128 KPH.
➋ Dimensions may vary- Consult your local sales representative for specifications.
➌ Square steel poles are furnished with anchor bolts and nuts, and 2-3/8”/60.5 mm O.D. x 4”/101.6 mm tenon, finished with bronzetone enamel and
cardboard wrapped. Touch-up paint furnished with every shipment.
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
1397
Areamaster Squarelite™ 400 Sharp Cutoff Luminaire Photometric Data
This report has been prepared in accordance with IES guides on testing
procedures. It is representative of luminaires tested under standardized and
stabilized laboratory conditions. Various operating factors can cause differences
between laboratory data and actual field performance.
Distance (ft)
Ahead/Behind
Footcandle
165
160
155
150
145
140
135
130
125
120
115
110
105
100
95
90
85
80
75
70
65
60
55
30
—
—
—
—
—
—
—
—
—
—
—
.01
.01
.02
.03
.05
.07
.10
.14
.23
.55
1.06
1.85
40
—
—
—
—
—
.01
.01
.01
.02
.03
.04
.05
.06
.08
.10
.21
.37
.60
.91
1.35
1.91
2.53
3.39
50
.01
.01
.01
.02
.02
.03
.03
.04
.05
.06
.10
.17
.26
.38
.54
.74
1.00
1.29
1.62
2.05
2.69
9.07
3.17
60
.02
.03
.03
.04
.04
.06
.09
.14
.20
.27
.35
.46
.60
.77
.93
1.13
1.37
1.66
2.02
2.16
2.21
2.21
2.18
50
3.08
4.55
3.19
2.34
45
4.51
4.93
3.16
2.24
40
35
30
25
20
15
10
5
0
-5
-10
-15
-20
-25
-30
6.64
8.65
8.85
8.95
9.25
11.4
13.7
12.7
6.58
1.15
.60
.77
1.13
1.11
.85
4.98
4.98
5.04
5.49
6.41
7.47
7.67
6.53
3.70
.81
.40
.31
.43
.59
.70
3.23
3.18
3.63
4.10
4.64
4.95
4.83
3.93
2.37
.58
.33
.23
.21
.26
.35
2.31
2.57
2.85
3.16
3.43
3.41
3.18
2.60
1.65
.48
.29
.18
.15
.15
.19
Mounting Height (Feet)
Distance in terms of mounting height ◊
Lighting: General Lighting — Area — Architectural
Lighting
Integrally Ballasted. For Double-Ended, Tubular 400 W HPS.
Photometric Number TSC2001-S2 Sharp Cutoff 400 W HPS Luminaire G-SC776L-MT. (HPS 400 W LU400/T7, 46,000 lumens).
Distance in terms of mounting height ◊
400W HPS
Mtg.
Ht.
20
25
30
35
40
45
Ft. Candles for Iso-Footcandle Lines
A
29.03
18.58
12.90
9.48
7.26
5.73
B
20.21
12.91
8.98
6.60
5.05
4.00
C
19.19
12.28
8.53
6.27
4.80
3.79
D
8.07
5.16
3.59
2.63
2.02
1.59
E
2.39
1.53
1.06
.78
.60
.47
F
.39
.25
.17
.13
.10
.08
G
.17
.11
.08
.06
.04
.03
H
.04
.04
.03
.02
.02
.01
◊ Distance in terms of mounting height (i.e., ratio) of distance to height. Example: @ 15 foot/4.6 meters mounting height, 1 means 15 foot/4.6 meters; 2 means
30 foot/9.1 meters, etc.)
* Additional photometric charts available on request.
1398
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
Round Tapered Steel Poles
Applications
• To mount single or multiple luminaires to heights from 20 to 39
feet/6.1 to 11.9 meters.
Features
Lighting
4.0"/
101.6 mm
• 2”/50.8 mm pipe size tenon accepts a single luminaire, or 2, 3,
or 4 luminaires with appropriate pole-top mounting bracket.
• Shafts are tapered, one-section
design of 11 gauge commercial quality steel with a minimum
yield strength of 55,000 psi after fabrication.
• Base plates are of structural quality hot-rolled steel with
guaranteed minimum yield strength of 36,000 psi.
• A 4” x 6-1/2”/101.6 x 165.1 mm reinforced handhole with
cover and grounding lug 14”/55.6 mm above the pole base is
standard.
• Anchor bolts are furnished complete with nuts and washers,
and are of 55,000 psi steel.
2"/50.8 mm
Pipe Size Tenon
(2-3/8"/60.5 mm O.D)
Lighting: General Lighting — Area — Poles and Hangers
Standard Finishes
• Poles are finished with red-oxide prime-paint after fabrication
Options
• For bronze powder coat finish (to match Appleton fixtures) add
Suffix -EPX.
• For galvanized finish add -GAL.
14.0"/
355.6 mm
Dimensions may vary. Consult your local sales representative for specifications
Mounting
Height
Ft/M
A
Shaft Size ➋
Base Size
In/mm
S➊
Bolt Circle
In/mm
BC
Base
Thickness
In/mm
T➊
Bolt Proj.
In/mm
P➊
Tube
Diameter
In/mm
D
Anchor Bolt
Dia. x Lgth.
In/mm
Max.
Proj Area
Sq.Ft./Sq.M.➌
Catalog
Number ➍
20/6.1
6.5 x 3.7 x 20’/
165.1 x 94.0 x 6.1
10.0/254.0
➊
1.0/25.4
2.25/57.2
6.5/165.1
1 x 40/
25.4 x 1016
18.7/1.74
G-PRTH-20
25/7.6
7.0 x 3.5 x 25’/
177.8 x 88.9 x 7.6
10.5/266.7
➊
1.0/25.4
2.25/57.2
7.0/177.8
1 x 40
25.4 x 1016
14.4/1.34
G-PRTH-25
30/9.1
8.0 x 3.8 x 30’/
203.2 x 96.5 x 9.1
11.5/292.1
➊
1.0/25.4
2.25/57.2
8.0/203.2
1 x 40
25.4 x 1016
14.5/1.35
G-PRTH-30
35/10.7
8.5 x 3.6 x 35’/
215.9 x 91.4 x 10.7
12.0/304.8
➊
1.0/25.4
2.25/57.2
8.5/215.9
1 x 40
25.4 x 1016
12.6/1.17
G-PRTH-35
39/11.9
9.0 x 3.5 x 39’/
228.6 x 88.9 x 11.9
13.0/330.2
➊
1.0/25.4
2.25/57.2
9.0/228.6
1 x 40
25.4 x 1016
11.7/1.09
G-PRTH-39
➊ Dimensions may vary—Consult your local sales representative for specifications.
➋ Shaft bottom (In. Dia./MM. Dia) x shaft top (In. Dia./MM.Dia.) x shaft length to tenon.
➌ Calculated for winds of 100 MPH/160 KPH.
➍ Anchor bolts and nuts are furnished.
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
1399
Hinged Steel Poles
Applications
Lighting: General Lighting — Area — Poles and Hangers
Lighting
• To mount single or multiple luminaires to heights from 20 to 35
feet/6.1 to 9.1 meters. Hinged design allows easy servicing of
luminaires at shoulder height.
2"/50.8 mm Pipe Size Tenon
(2-3/8"/60.5 mm)
4.0"/
101.6
mm
Features
• Shafts are structural steel with a minimum yield strength of
46,000 psi.
• Heavy duty hinge assembly secures upper section to lower
section with high strength 3/4”/19.05 mm Dia. bolt. A flexible
protective channel is provided to protect wires when pole is
lowered.
• Pole counter-balance is designed to offset weight of luminaires
and is made from steel with minimum yield strength of 36,000
psi.
• Base plates are of structural quality hot-rolled steel with
minimum yield strength of 36,000 psi.
• A 3” x 5”/76.2 x 127 mm reinforced handhole with cover and
grounding lug 14”/355.6 mm above the pole base is standard.
• Anchor bolts are furnished complete with nuts and washers,
and are of 50,000 psi steel.
Standard Finishes
• Poles are finished with red-oxide prime-paint after fabrication
Options
14.0"/
355.6
mm
• For bronze powder coat finish (to match Appleton fixtures) add
suffix -EPX. For galvanized finish add -GAL.
• An optional lowering winch is available and recommended for
easy one-man operation of hinged poles. (Only one lowering
winch per installation is required because winch assembly
mounts from pole to pole and dismounts for easy storage.)
Lowering winch is furnished with mounting hardware, 25
feet/7.62 m of 3/16”/4.8 mm galvanized wire rope and safety
snap hook.
Accessory: GLW –
Lowering Device (Winch)
Dimensions may vary. Consult your local sales representative for specifications
Mounting
Height
ft/m
A
Shaft Size
(In.Sq./mm.Sq. x Ga.)
Base
Base Size
Bolt Circle Thickness Bolt Proj.
In. Sq/mm. Sq
In/mm
In/mm
In/mm
S➊
BC
T
P
F
E
20/6.1
4/2580.6 x 7
4/2580.6 x 11
10.0/6451.6
➊
.75/19.1
20/6.1
5/3225.8 x 7
5/3225.8 x 11
11.5/7419.3
➊
1.0/25.4 2.25/57.2
24/7.32
4/2580.6 x 7
4/2580.6 x 11
10.0/6451.6.
➊
.75/19.1
24/7.32
6/3871.0 x 7
6/3871.0 x 11
12.0/7741.9
➊
1.0/25.4 2.25/57.2
30/9.14
4/2580.6 x 7
4/2580.6 x 11
10.0/6541.6
➊
.75/19.1
30/9.14
6/3871.0 x 7
6/3871.0 x 11
12.0/7741.9
➊
1.0/25.4 2.25/57.2
35/10.67
6/3871.0 x 7
6/3871.0 x 11
12.0/7741.9
➊
1.0/25.4 2.25/57.2
2.0/50.8
2.0/50.8
2.0/50.8
Anchor Bolt
Max.
Dia. x Lgth.
Proj Area
In/mm
Sq.Ft./Sq.M. ➌
.75 x 28/
9.3/0.86
19.1 x 711.2
1.0 x 40/
15.2/1.4
25.4 x 1016
.75 x 28/
6.1/0.57
19.1 x 711.2
1.0 x 40/
14.3/1.33
25.4 x 1016
.75 x 28/
2.9/0.27
19.1 x 711.2
1.0 x 40/
10.8/1.00
25.4 x 1016
1.0 x 40/
3.6/0.33
25.4 x 1016
Loading
Weight
lbs/kgs
Catalog
Number ➋
230/104.3 G-PHSM-20
350/158.8 G-PHSH-20
170/77.1 G-PHSM-24
280/127.0 G-PHSH-24
150/68.0 G-PHSM-30
240/108.9 G-PHSH-30
180/81.6 G-PHSH-35
➊ Dimensions may vary—Consult your local sales representative for specifications.
➋ Anchor bolts and nuts are furnished. For accessory lowering winch, specify Cat. No. GLW.
➌ Calculated for winds of 100 MPH/160 KPH.
1400
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
Square Tapered Steel Poles
Applications
• To mount single or multiple luminaires to heights from 20 to 39
feet/6.1 to 11.9 meters.
4.0"/
101.6 mm
2"/50.8 mm
Pipe Size Tenon
(2-3/8"/60.5 mm O.D)
Lighting: General Lighting — Area — Poles and Hangers
• 2”/0.61 mm pipe size tenon accepts a single luminaire or 2, 3,
or 4 luminaires with appropriate pole-top mounting bracket.
• High strength shafts have a uniform taper and are made from
11 gauge commercial quality hot rolled steel.
• Base plates are of structural quality hot rolled steel with
minimum yield strength of 36,000 psi.
• A 3” x 5”/76.2 x 127 mm reinforced handhole with cover and
grounding lug 14”/355.6 mm above the pole base is standard.
• Anchor bolts are furnished complete with nuts and washers,
and are of 55,000 psi steel.
Lighting
Features
Standard Finishes
• Poles are finished with red-oxide prime-paint after fabrication
Options
• For bronze powder coat finish (to match Appleton fixtures) add
Suffix -EPX. For galvanized finish add suffix -GAL.
14.0"/
355.6 mm
Dimensions may vary. Consult your local sales representative for specifications
Mounting
Height
Ft/M
A
Shaft Size ➊
Sq.In./Sq.MM. x Ft/M
Base Size
In/mm
S➋
Bolt Circle
In/mm
BC
Base
Thickness
In/mm
T➋
Bolt Proj.
In/mm
P➋
Anchor Bolt
Dia. x Lgth.
In/mm
Max. Proj Area
Sq.Ft/Sq.M ➌
Catalog
Number ➍
20/6.1
5.25 x 3.25 x 20’/
3387 x 2097 x 6.1
10.5/266.7
➋
1.0/25.4
2.25/57.2
1 x 40/
25.4 x 1016.0
9.4/0.87
G-PSTH-20
24/7.3
6.25 x 3.85 x 24’/
4032 x 2484 x 12.2
13.0/330.2
➋
1.0/25.4
2.25/57.2
1 x 40/
25.4 x 1016.0
8.9/0.83
G-PSTH-24
30/9.1
6.65 x 3.25 x 30’/
4290 x 2097 x 9.1
12.0/304.8
➋
1.0/25.4
2.25/57.2
1 x 40/
25.4 x 1016.0
5.8/0.54
G-PSTH-30
35/10.7
6.25 x 3.25 x 35’/
4032 x 2097 x 10.7
13.0/330.2
➋
1.0/25.4
2.25/57.2
1 x 40/
25.4 x 1016.0
4.4/0.41
G-PSTH-35
39/11.9
7.15 x 3.25 x 39’
4613 x 2097 x 11.9
13.0/330.2
➋
1.0/25.4
2.50/63.5
1 x 40/
25.4 x 1016.0
3.8/0.35
G-PSTH-39
➊ Shaft bottom (Sq. In.) x shaft top (Sq. In.) x shaft length to tenon.
➋ Dimensions may vary—Consult your local sales representative for specifications.
➌ Calculated for winds of 100 MPH.
➍ Anchor bolts and nuts are furnished.
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
1401
Square Steel Poles
Applications
Lighting: General Lighting — Area — Poles and Hangers
Lighting
• To mount single or multiple luminaires to heights from 14 to 30
feet/4.3 to 9.1 meters.
Features
4.0"/
101.6
mm
• 2”/50.8 mm pipe size tenon accepts a single luminaire, or 2, 3,
or 4 luminaires with appropriate pole-top mounting bracket.
• High strength shafts are made from square steel structural tube
with minimum yield strength of 46,000 psi.
• Base plates are of structural quality hot-rolled steel with
minimum yield strength of 36,000 psi.
• A 3” x 5”/76.2 x 127 mm reinforced handhole with cover and
grounding lug 14”/355.6 mm above the pole base is standard.
• Anchor bolts are furnished complete with nuts and washers,
and are of 55,000 psi steel.
2"/50.8 mm Pipe Size Tenon
(2-3/8"/60.5 mm)
Standard Finishes
• Poles are finished with red-oxide prime-paint after fabrication
Options
• For bronze powder coat finish (to match Appleton fixtures) add
Suffix -EPX. For galvanized finish add suffix -GAL.
14.0"/
355.6
mm
Dimensions may vary. Consult your local sales representative for specifications
Mounting
Height
Ft/M
A
Shaft Size ➊
In/mm
Base Size
In/mm
S➋
Bolt Circle
In/mm
BC
Base
Thickness
In/mm
T➋
Bolt Proj.
In/mm
P➋
Anchor Bolt
Dia. x Lgth.
In/mm
Max. Proj Area
Sq.Ft./Sq.M. ➌
Catalog
Number ➍
14/4.3
4” x 4” x 11Ga./
101.6 x 101.6 x 11Ga.
8.0/203.2
➋
.75/19.1
2.00/50.8
.75 x 20/
19.1 x 508.0
10.9/1.01
G-PSSM-14
14/4.3
4” x 4” x 7Ga./
101.6 x 101.6 x 11Ga.
8.0/203.2
➋
.75/19.1
2.00/50.8
.75 x 20/
19.1 x 508.0
14.4/1.34
G-PSSH-14
17/5.2
4” x 4” x 11Ga./
101.6 x 101.6 x 11Ga.
8.0/203.2
➋
.75/19.1
2.00/50.8
.75 x 20/
19.1 x 508.0
6.9/0.64
G-PSSM-17
17/5.2
4” x 4” x 7Ga./
101.6 x 101.6 x 7Ga.
8.0/203.2
➋
.75/19.1
2.00/50.8
.75 x 20/
19.1 x 508.0
11.9/1.11
G-PSSH-17
20/6.1
4” x 4” x 7Ga./
101.6 x 101.6 x 7Ga.
8.0/203.2
➋
.75/19.1
2.00/50.8
.75 x 20/
19.1 x 508.0
10.1/0.94
G-PSSM-20
20/6.1
5” x 5” x 7Ga./
127.0 x 127.0 x 7Ga.
11/279.4
➋
1.0/25.4
2.25/57.2
1 x 40/
25.4 x 1016
17.2/1.60
G-PSSH-20
24/7.3
5” x 5” x 7Ga./
127.0 x 127.0 x 11Ga.
11/279.4
➋
1.0/25.4
2.25/57.2
1 x 40/
25.4 x 1016
11.9/1.11
G-PSSM-24
24/7.3
6” x 6” x 7Ga./
152.4 x 152.4 x 7Ga.
12.0/304.8
➋
1.0/25.4
2.25/57.2
1 x 40/
25.4 x 1016
18.8/1.75
G-PSSH-24
30/9.1
5” x 5” x 7Ga./
127.0 x 127.0 x 7Ga.
11/279.4
➋
1.0/25.4
2.25/57.2
1 x 40/
25.4 x 1016
6.9/0.64
G-PSSM-30
30/9.1
6” x 6” x 7Ga./
152.4 x 152.4 x 7Ga.
12.0/304.8
➋
1.0/25.4
2.25/57.2
1 x 40/
25.4 x 1016
11.7/1.09
G-PSSH-30
➊ Shaft bottom (Sq. In.) x shaft top (Sq. In.) x shaft length to tenon.
➋ Dimensions may vary—Consult your local sales representative for specifications.
➌ Calculated for winds of 100 MPH.
➍ Anchor bolts and nuts are furnished.
1402
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
Floodlight Mounting Brackets
Single or Multiple Installation on Wall, Wood or Metal Poles
Metal Pole Brackets
Lighting
Lighting: General Lighting — Area — Poles and Hangers
Wood Pole Brackets
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
1403
Floodlight Mounting Brackets
Single or Multiple Installation on Wall, Wood or Metal Poles
Lighting
Poletop Brackets for Metal Poles — Dimensions may vary. Consult your local sales representative for specifications
Floodlight mounting brackets for installation of 2 to 4 floodlights atop metal poles are manufactured from high-strength steel tube, and
slip-fit onto 2”/50.8 mm pipe size poletop tenons. Furnished with 3 locking setscrews and red oxide prime coat finish. Bracket tenon is
2”/50.8 mm pipe size (2-3/8”/60.5 mm O.D.).
Dimensions
17.0"/
431.8 mm
Description
17.0"/
431.8 mm
10.0"/
254.0 mm
Lighting: General Lighting — Area — Poles and Hangers
Catalog Number
Poletop Bracket for Two Luminaires
G-PB-2
Poletop Bracket for Three Luminaires
G-PB-3
Poletop Bracket for Three Luminaires (120° apart)
G-PB-3-120
Poletop Bracket for Four Luminaires (in line)
G-PB-14
Poletop Bracket for Four Luminaires
G-PB-4
1.0"/25.4 mm
5.0"/
127.0 mm
(3) 3/8"/9.7 mm x 5/8"/16.0 mm
Setscrews at 120 °
Slip-Fitter for 2"/50.8 mm
Std. Pipe
17.0"/
431.8 mm
17.0"/
431.8 mm
2.0"/
50.8 mm
Std. Pipe
20.0"/
508.0 mm
10.0"/
254.0 mm
1.0"/25.4 mm
5.0"/
127.0 mm
Slip-Fitter for 2"/50.8 mm
Std. Pipe
(3) 3/8"/9.7 mm x 5/8"/16.0 mm
Setscrews at 120 °
17.0"/
431.8 mm R.
30.0"/
762.0 mm
10.0"/
254.0 mm
30.0"/
762.0 mm
1-1/8"/
28.7 mm
Dia. Hole for
wiring
30.0"/
762.0 mm
2.0"/
50.8 mm
Std. Pipe
1.0"/25.4 mm
5.0"/
127.0 mm
(3) 3/8"/9.7 mm x 5/8"/16.0 mm
Setscrews at 120 °
17.0"/
431.8 mm R
10.0"/
254.0 mm
Slip-Fitter for 2"/50.8 mm
Std. Pipe
34.0"/
863.6 mm
2.0"/
Removable
50.8 mm
Cap
Std. Pipe
5.0"/
127.0 mm
Slip-Fitter for 2"/50.8 mm
Std. Pipe
1404
0.5"/12.7 mm
(3) 3/8"/9.7mm x 5/8"/16.0 mm
Setscrews at 120 °
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
Floodlight Mounting Brackets
Single or Multiple Installation on Wall, Wood or Metal Poles
Poletop Reducers
Made from high strength steel tubing, complete with 3 locking setscrews and with red-oxide prime finish.
Poletop Pipe Size Reduction
In/mm
Catalog Number
2-1/2 to 2/63.5 to 50.8
G-PR-2-1/2
Lighting
Dimensions — May vary. Consult your local sales
representative for specifications
2"/50.8 mm Pipe Size
(2-3/8"/60.5 mm O.D.)
G-PR-3
3 to 2/76.2 to 50.8
4.0"/
101.6 mm
G-PR-3-1/2
3-1/2 to 2/88.9 to 50.8
G-PR-4
5 to 2/127 to 50.8
G-PR-5
4.0"/
101.6 mm
8.0"/
203.2 mm
Lite Mount Bars for 4, 8, or 12 Quartzlite or Areamaster Jr. Floodlights
Bars have 11 gauge steel body and 12 gauge steel cover. Two styles: to mount on 2”/50.8 mm pipe size poletop tenon, or on wood poles
using thru-bolts. Welded construction, with 3/4”/19.1 mm N.P.S. tapped hubs. Rain-tight, with red-oxide prime finish.
Dimensions — May vary. Consult your local sales
representative for specifications
Number of
Fixtures
Length A
Dim. B
Dim C
Dim. D
4
28
–
25
1-1/2
8
60
17
24-1/2
1-1/4
12
96
17
25
1-1/2
For Metal Poles
4.0"/
101.6 mm
Dimensions For Mounting Quartzlites or Areamaster Jr.
Number of Fixtures For
Mounting
Catalog Number
Metal Pole
Wood Pole
4 Fixtures
G-PQM-4T
G-PQM-4W
8 Fixtures
G-PQM-8T
G-PQM-8W
12 Fixtures
G-PQM-12T
G-PQM-12W
Bar Assembly for 2"/50.8 mm
Pipe Size Tenon
(3) Setscrews
2"x4"/50.8 x 101.6 mm
Access Door
NPT Light Mount Type
For Wood Poles
NPT Light Mount Type
11.0"/
279.4 mm
2"x4"/
50.8 x 101.6 mm
Access Door
11/16"/17.5 mm Dia. Holes
4.0"/
101.6 mm
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
1405
Lighting: General Lighting — Area — Poles and Hangers
4 to 2/101.6 to 50.8
Floodlight Mounting Brackets
Single or Multiple Installation on Wall, Wood or Metal Poles
Dimensions may vary. Consult your local sales representative for specifications
Description
Lighting
For Floodlights with 2”/50.8 mm Slip-Fitter, or will mount G-PB
Series brackets with floodlights.
• Complete with two 13”/330.2 mm-long bolts, washers, and
nuts.
• Red oxide prime coat finish.
Lighting: General Lighting — Area — Poles and Hangers
8-1/2"/
215.9 mm
8.0"/
203.2 mm
Catalog Number
Wood Pole or Wall Mounting Bracket
5.0"/
127.0 mm
2"/50.8 mm
Pipe
7-1/2"/
190.5 mm
G-PCB-1
G-PWB-1
Wood Pole Clamp Brackets
• Pole clamping floodlight mounting brackets constructed of
2”/50.8 mm steel pipe.
• Furnished complete with clamping bolts and nuts.
• Has red oxide primer coat finish.
• For 1 to 3 floodlights—Fits 6”/152.4 mm to 9”/228.6 mm poles.
• For 4 floodlights—Fits 9”/228.6 mm to 12”/304.8 mm poles.
1 Arm
G-PCB-1
2 Arm
G-PCB-2
3 Arm
G-PCB-3
4 Arm
G-PCB-4
G-PCB-2
G-PCB-3
G-PCB-4
6"/152.4 mm Channel
@ 8.2 lbs/3.7 kgs
6.0"/
152.4 mm
24.0"/
609.6 mm
9/16"/0.56 mm Dia.
holes for floodlight mounting
24.0"/
609.6 mm
1-1/2"/
38.1 mm
9.0"/228.6 mm
24.0"/
609.6 mm
6.0"/
152.4 mm
Mounting arm made of rugged angular steel stock with
1/4” supporting struts. Has hot-dipped galvanized finish.
Furnished with all nuts and bolts to assemble and install
bracket to wood pole.
2 holes, 7/8"/
22.4 mm Dia.
(3/4"/19.1 mm Dia.
thru-bolts furnished)
12.0"/304.8 mm
4" x 3"x 1/4"/
101.6 x 76.2 x 6.4 mm
Angle
1406
Wood Pole Crossarm Lite Mount Bracket
4-Lite
G-PCAB-4
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
AHG and UNJ Flexible Fixture Hangers
Malleable Iron. Ball Type.:15° Swing. Cushion Type: 8° Swing
UNILETS® for Use with Threaded Rigid Metal Conduit and IMC.
Applications
• AHG cushion hangers are enclosed and gasketed—ideal where
dust and dampness are present.
Features
AHG5050
UNJ-50
Illustrated Features
Lighting
• All hangers
— All fixture hangers protect fixture against wind and vibration
damage.
— Cushion type for added protection where lighting fixtures are
subjected to vibration.
• AHG hangers
— Enclosed and gasketed.
— Neoprene diaphragm keeps moisture and dirt out of system.
— Cushion type permits 8° swing from vertical.
• UNJ hangers
— Economical general purpose hanger.
— Permits 15° swing.
Standard Materials
• AHG fixture hangers: malleable iron
• UNJ fixture hangers: malleable iron and steel
Standard Finishes
Lighting: Flexible Fixture Hangers — Ordinary Location
• AHG: triple-coat—(1) zinc electroplate, (2) chromate, and (3)
epoxy powder coat
• UNJ: malleable iron and steel parts, zinc electroplate and clear
chromate
Certifications and Compliances
• CSA Certified: 065180 (UNJ)
• UL Listed: E109438 (AWG)
Fixture Stem
Size (Inches)
Male Nipple
Size (Inches)
Length A
in/mm
Support Weight
(lbs/kg)
Catalog
Number
AHG — Fixture Hangers — Cushion Type — Enclosed and Gasketed — Cushions 40 lbs./18.0 kg.
A
1/2
1/2
3.19/81.0
1/2
3/4
3.19/81.0
3/4
3/4
3.19/81.0
AHG5050
40/18
AHG7550
AHG7575
Cushion
UNJ — Fixture Hangers — Malleable Iron and Steel — Ball Type
1/2
1/2
4.00/101.6
3/4
3/4
4.00/101.6
120/54
UNJ-50
UNJ-75
A
Ball
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
1407
AL Ball and Cushion Flexible Fixture Hangers
UNILETS® for Use with Threaded Rigid Metal Conduit and IMC. Ball Joint Permits 20° Swing.
Applications
• Designed for suspension of HID, fluorescent and incandescent
lighting fixtures.
• Functions as combination conduit outlet box and hanger.
Lighting
Features
• Protects fixture against wind and vibration damage.
• Cushion type for added protection where lighting fixtures are
subjected to vibration.
• Dual function—conduit outlet box and fixture hanger.
• Choice of ball or cushion type.
• Swivel joint construction—allows 20° swing from vertical.
• Cushion style, with conical spring, supports up to 120 lbs/54 kg.
• Cushion type has setscrew for locking fixture stem.
• Fixture and hanger stem can be wired at work bench.
• Connection block available for convenient wiring of fixture leads.
ALA — Ball Hanger
ALC — Ball Hanger
ALL — Cushion Hanger
ALT — Cushion Hanger
Standard Materials
• Malleable iron with steel cover
Standard Finishes
Lighting: Flexible Fixture Hangers — Ordinary Location
• Malleable iron parts: triple-coat—(1) zinc electroplate,
(2) chromate, and (3) epoxy powder coat
• Steel parts: zinc electroplate
Certifications and Compliances
• UL Listed: E109438
Illustrated Features
1408
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
AL Ball and Cushion Flexible Fixture Hangers
UNILETS® for Use with Threaded Rigid Metal Conduit and IMC. Ball Joint Permits 20° Swing.
Conduit Size
(Inches)
Fixture Stem Size
(Inches)
Support Weight
(lbs/kg)
Catalog
Number
ALA — Ball Hanger
1/2
1/2
3/4
1/2
3/4
3/4
250/112.5
250/112.5
ALA50-B
ALA7550-B
ALA75-B
ALA — Cushion Hanger — Furnished with a 3/4” to 1/2 reducer for 1/2” stems
1/2
3/4 or 1/2
3/4
3/4 or 1/2
3/4 or 1/2
3/4 or 1/2
1/2
3/4 or 1/2
3/4
3/4 or 1/2
1/2
1/2
3/4
1/2
1
1/2
3/4
3/4
1
3/4
12 to 48/5.4 to 21.6
48 to 120/21.6 to 54.0
ALA50-12
ALA7575-12
ALA50-48
Lighting
1/2
3/4
3 to 12/1.4 to 5.4
ALA7575-48
ALA50-120
ALA7575-120
Lighting: Flexible Fixture Hangers — Ordinary Location
ALC — Ball Hanger
ALC50-B
250/112.5
ALC7550-B
ALC1050-B
250/112.5
ALC75-B
ALC1075-B
ALC — Cushion Hanger — Furnished with a 3/4” to 1/2” reducer for 1/2” stems
1/2
3/4 or 1/2
3/4
3/4 or 1/2
ALC50-12
3 to 12/1.4 to 5.4
ALC7575-12
1
3/4 or 1/2
ALC1075-12
1/2
3/4 or 1/2
ALC50-48
3/4
3/4 or 1/2
1
3/4 or 1/2
1/2
3/4 or 1/2
3/4
3/4 or 1/2
1
3/4 or 1/2
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
12 to 48/5.4 to 21.6
ALC7575-48
ALC1075-48
ALC50-120
48 to 120/21.6 to 54.0
ALC7575-120
ALC1075-120
1409
AL Ball and Cushion Flexible Fixture Hangers
UNILETS® for Use with Threaded Rigid Metal Conduit and IMC. Ball Joint Permits 20° Swing.
Conduit Size
(Inches)
Fixture Stem Size
(Inches)
1/2
1/2
Support Weight
(lbs/kg)
Catalog
Number
ALL — Ball Hanger
3/4
1/2
3/4
3/4
250/112.5
250/112.5
ALL50-B
ALL7550-B
ALL75-B
Lighting: Flexible Fixture Hangers — Ordinary Location
Lighting
ALL — Cushion Hanger — Furnished with a 3/4” to 1/2” reducer for 1/2” stems
1/2
3/4 or 1/2
3/4
3/4 or 1/2
1/2
3/4 or 1/2
3/4
3/4 or 1/2
1/2
3/4 or 1/2
3/4
3/4 or 1/2
1/2
1/2
3/4
1/2
1
1/2
3/4
3/4
3 to 12/1.4 to 5.4
12 to 48/5.4 to 21.6
48 to 120/21.6 to 54
ALL50-12
ALL7575-12
ALL50-48
ALL7575-48
ALL50-120
ALL7575-120
ALT — Ball Hanger
1
ALT50-B
250/112.5
ALT7550-B
ALT1050-B
ALT75-B
250/112.5
3/4
ALT1075-B
ALT — Cushion Hanger — Furnished with a 3/4” to 1/2” reducer for 1/2” stems
1410
1/2
3/4 or 1/2
3/4
3/4 or 1/2
1
3/4 or 1/2
1/2
3/4 or 1/2
3/4
3/4 or 1/2
ALT50-12
3 to 12/1.4 to 5.4
ALT7575-12
ALT1075-12
ALT50-48
12 to 48/5.4 to 21.6
ALT7575-48
1
3/4 or 1/2
ALT1075-48
1/2
3/4 or 1/2
ALT50-120
3/4
3/4 or 1/2
1
3/4 or 1/2
48 to 120/21.6 to 54
ALT7575-120
ALT1075-120
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
AL Flexible Fixture Hanger Parts and Dimensions
UNILETS® for Use with Threaded Rigid Metal Conduit and IMC.
Size
(Inches)
AL — Hanger Bodies
ALA
ALC
ALL
Catalog
Number
1/2
ALA50
3/4
ALA75
1/2
ALC50
3/4
ALC75
1
ALC100
1/2
ALL50
3/4
ALL75
1/2
ALT50
3/4
ALT75
1
ALT100
Lighting
ALT
Support Weight
(lbs/kg)
Lighting: Flexible Fixture Hangers — Ordinary Location
AL — Ball Fixture Stem
BJ50
1/2
250/112.5
3/4
BJ75
AL — Cushion Fixture Stems
Fixture stem tapped for 3/4”; 3/4” to 1/2" reducer furnished for 1/2” stems. With setscrew for locking fixture stem.
3/4 or 1/2
3-12 / 1.4-5.4
CJC75-12
3/4 or 1/2
12-48 / 5.4-21.6
CJC75-48
3/4 or 1/2
48-120 / 21.6-54.0
CJC75-120
AL — Porcelain Connection Block
2 Wire, 20 Amp, 277 Volt
Maximum Wire Size
Two No. 10 AWG Large Terminal
Two No. 14 AWG Small Terminal
CB202
AL Fixture Hanger Dimensions
Top View
.88"/
22.4 mm
1.81"/
46.0 mm
2.0"/
50.8 mm
Conduit Trade
Size
.25"/6.4 mm Dia.
.88"/
22.4 mm
Front View
Cushion Stem
.25"/
6.4 mm
3.00"/
76.2 mm
4.13"/
104.9 mm
Dimensions in Inches/Millimeters
A
B
1/2”
0.56/4.2
0.69/17.5
3/4”
0.69/17.5
0.69/17.5
1”
0.88/22.4
0.81/20.6
7.38"/
187.5 mm
4.00"/
101.6 mm
Side View
Ball Stem
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
1411
JB and GS Flexible Fixture Hangers
Malleable Iron. Ball Type, 15° Swing; Cushion Type, 8° Swing
UNILETS® for Use with Threaded Rigid Metal Conduit and IMC.
Applications
• JB, GS and AHG cushion hangers are enclosed and gasketed—
ideal where dust and dampness are present.
• JB and GS hangers designed for use with JB and GS boxes.
Lighting
Features
• All hangers
— All fixture hangers protect fixture against wind and vibration
damage.
— Cushion type for added protection where lighting fixtures are
subjected to vibration.
• JB and GS hangers
— Mount directly to JB and GS cast conduit outlet boxes.
— Choice of ball or cushion type.
— Ball type permits 15° swing, cushion type 8° swing from
vertical
— Cushion type is enclosed and gasketed.
JBK-50-BS
JBK-50-CS
GSK-50-20B
GSK-50-20C
Standard Materials
• Malleable iron
Lighting: Flexible Fixture Hangers — Ordinary Location
Standard Finishes
• GS: triple-coat—(1) zinc electroplate, (2) chromate, and (3)
epoxy powder coat
• JB series support: zinc electroplate and clear chromate
Certifications and Compliances
• JB and GS cushion type hangers suitable for classified location
use in Class I, Division 2 areas, if installed in compliance with
NEC 501-9(b)
• CSA Certified: 065180
• UL Listed: E109438
Illustrated Features
Mercmaster HID Lighting Fixture
1412
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
JB and GS Flexible Fixture Hangers
Malleable Iron. Ball Type, 15° Swing; Cushion Type, 8° Swing
UNILETS® for Use with Threaded Rigid Metal Conduit and IMC.
Fixture Stem
Size (Inches)
Male Nipple
Size (Inches)
Length A
in/mm
Support Weight
(lbs/kg)
Catalog
Number
JB—Fixture Hanger Covers — For use with JBX, JBDX and JBLX bodies — Furnished with gasket and screws
Ball Type
A
1/2
2.56/65.0
250/113
JBK-50-BS
3/4
2.56/65.0
.
JBK-75-BS
40/18
JBK-50-CS
Cushion Type
Enclosed and gasketed. Cushions 40 lbs./18.0 kg.
A
1.63/41.4
3/4
1.63/41.4
JBK-75-CS
GS—Fixture Hanger Covers (Form 20) — For use with GS and GSU bodies — Furnished with gasket and screws
Lighting
1/2
Ball Type
A
1/2
3.00/76.2
3/4
3.25/82.6
250/113
GSK-50-20B
GSK-75-20B
A
Enclosed and gasketed. Cushions 40 lbs./18.0 kg.
1/2
2.00/50.8
3/4
2.00/50.8
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
40/18
GSK-50-20C
GSK-75-20C
1413
Lighting: Flexible Fixture Hangers — Ordinary Location
Cushion Type
SSH Flexible Fixture Hangers
Heavy Duty Outlet Box Swivel. Ball Joint Swivel Permits 20° Swing
UNILETS® for Use with Threaded Rigid Metal Conduit and IMC.
Applications
• Designed for suspension of HID, fluorescent and incandescent
lighting fixtures.
• SSH heavy duty swivel hangers for mounting to outlet and
concrete boxes.
Features
• Protect fixture against wind and vibration damage.
• Cushion type for added protection where lighting fixtures are
subjected to vibration.
• Heavy duty—support fixtures up to 50 lbs/22.7 kg.
• Steel plate serves as cover for outlet or concrete box.
• Ball type swivel joint permits 20°swing from vertical.
Standard Materials
Lighting
• Malleable iron and steel
11360
11362
Standard Finishes
• Malleable iron and steel parts: zinc electroplate and clear
chromate
Lighting: Flexible Fixture Hangers — Ordinary Location
Certifications and Compliances
• CSA Certified: 065180
• UL Listed: E2527
• UL Standard: 514A
Illustrated Features
Industrial lighting installations often employ the
use of extra heavy fixtures requiring a properly
anchored swivel attachment, assuring positive
safety to carry the necessary weight. In the Type
“SSH” Safety Swivel Hanger, the weight of the
entire suspended unit is borne by a fixture stud
instead of relying upon the screws and screw
ears of the box or ring for support. The “SSH”
hanger is furnished with a steel plate to serve
as a cover for the 4” Concrete, Octagonal, and
4-11/16” Square boxes.
Cat. No. 11360 Safety Swivel Hanger
installed in OCR3-1/2 Concrete Box
with OCP3/8 Plate
1414
Cat. No. 11362 Safety Swivel Hanger
installed in a 4-11/16” Square Box
shown with NBFS-38 (not included)
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
SSH Flexible Fixture Hangers
Heavy Duty Outlet Box Swivel. Ball Joint Swivel Permits 20° Swing
UNILETS® for Use with Threaded Rigid Metal Conduit and IMC.
Fixture Stem Size
(Inches)
Fixture Stud Size
(Inches)
Length A
in/mm
Support Weight
(lbs/kg)
Catalog
Number
2.19/55.6
50/22.5
11360
50/22.5
11355
50/22.5
11362
Concrete Box — Safety Swivel Hanger — For Concrete Box 2-1/2” to 4” Deep
1/2
3/8
A
1/2
3/8
2.19/55.6
Lighting
Octagonal Box — Safety Swivel Hanger — For 4” Octagonal Box 1-1/2” or 2-1/8” Deep
A
1/2
3/8
2.19/55.6
A
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
1415
Lighting: Flexible Fixture Hangers — Ordinary Location
Square Box — Safety Swivel Hanger — For 4-11/16” Square Box 1-1/2” or 2-1/8” Deep
SHC Flexible Fixture Hangers
Outlet Box Mounted Series
UNILETS® for Use with Threaded Rigid Metal Conduit and IMC.
Applications
• Designed for suspension of HID, fluorescent and incandescent
lighting fixtures.
• SHC fixture hanger covers for mounting to 3-1/4” and 4”
octagonal boxes and 4” square boxes.
Features
• Protect fixture against wind and vibration damage.
• Cushion type for added protection where lighting fixtures are
subjected to vibration.
• Ball type swivel joint permits 20° swing from vertical.
• Support fixtures with a maximum weight of 50 lbs/22.7 kg.
8438R
8458R
Standard Materials
Lighting
• Steel and malleable iron
Standard Finishes
• Malleable iron and steel parts: zinc electroplate and clear
chromate
Illustrated Features
Ball Type Swivel
Fixture Hanger
Covers shown with
octagonal and with
square stamped steel
outlet boxes.
Certifications and Compliances
Lighting: Flexible Fixture Hangers — Ordinary Location
• CSA Certified: 065180
• UL Listed: E2527
• UL Standard: 514A
Related Products
• For steel boxes, see Commercial Products section.
Fixture Stem Size
(Inches)
Length A
in/mm
Support Weight
(lbs/kg)
Catalog
Number
SHC Ball Type Swivel Hanger Covers — Permit 20° swing from vertical
For 3-1/4” and 4” Octagonal Boxes
A
1/2
1.75/44.5
50/22.5
8438R
3/4
2.00/50.8
50/22.5
8436R
1/2
1.75/44.5
50/22.5
8458R
3/4
2.00/50.8
50/22.5
8456R
For 4” Square Boxes
A
1416
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
Flexible Fixture Hangers
Hook and Loop
UNILETS® for Use with Threaded Rigid Metal Conduit and IMC.
Applications
• Designed for suspension of HID, fluorescent and incandescent
lighting fixtures.
Features
EFHM
EFHF
FHS
Standard Finishes
Lighting
• Protect fixture against wind and vibration damage.
• Cushion type for added protection where lighting fixtures are
subjected to vibration.
• EF hook and loop hangers
— Malleable iron for strength and safety.
— Hook and loop combination permits quick disconnect and
removal of fixture for maintenance.
— Offer inexpensive means of pendant flexible suspension of
lighting fixtures.
— Permit free swing in any direction.
— EF jaw openings can be completely closed for added safety.
• FHS support hangers
— Provide up to 350 lbs/158.8kg support for fluorescent fixtures
on the non-electrical side of mounting.
— Straddle a maximum of 1-1/4” conduit and take 1/2” or 3/4”
fixture hook or conduit.
• Zinc electroplate and clear chromate
Certifications and Compliances
• CSA Certified: 065180
Standard Materials
• Malleable iron
Length A
(in/mm)
Support Weight
Lbs./Kg.
Catalog Number
1/2
2.63/66.8
200/90.0
EFHM-50
3/4
2.94/74.7
EF — Safety Support Hooks — With 3/8” jaw opening
EFHM—Male
A
EFHM
EFHM-75
EFHF—Female
A
1/2
2.00/50.8
3/4
2.05/52.1
200/90.0
EFHF-50
EFHF-75
EFHF
FHS — Support for Fixtures, Dummy Side — Straddles up to 1-1/4 trade size conduit — 11/32” diameter mounting holes, spaced
3-1/4” apart
1/2 or 3/4
A
3.31/87.1
350/157.5
FHS5075
Dimensions in Inches/Millimeters
0.38"/
9.7 mm
0.25"/
6.4 mm R
A
B
C
Catalog Number
1/2-14 NPT
2.00/50.8
2.63/66.8
EFHM-50
3/4-14 NPT
2.13/54.1
2.88/73.2
EFHM-75
1/2-14 NPT
2.00/50.8
N/A
EFHF-50
3/4-14 NPT
2.13/54.1
N/A
EFHF-75
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
1417
Lighting: Flexible Fixture Hangers — Ordinary Location
Size
(Inches)
Flexible Fixture Hangers
Hook and Loop
UNILETS® for Use with Threaded Rigid Metal Conduit and IMC.
Applications
• Designed for suspension of HID, fluorescent and incandescent
lighting fixtures.
Lighting
Features
• Protect fixture against wind and vibration damage.
• Cushion type for added protection where lighting fixtures are
subjected to vibration.
• Malleable iron for strength and safety.
• Hook and loop combination permits quick disconnect and
removal of fixture for maintenance.
• Offer inexpensive means of pendant flexible suspension of
lighting fixtures.
• Permit free swing in any direction.
• EF and FHSN jaw openings can be completely closed for
added safety.
FHLM
FHHM
FHSN
Standard Materials
• Malleable iron
Standard Finishes
• Zinc electroplate and clear chromate
Lighting: Flexible Fixture Hangers — Ordinary Location
Certifications and Compliances
• CSA Certified: 065180
Illustrated Features
1418
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
Flexible Fixture Hangers
Hook and Loop
UNILETS® for Use with Threaded Rigid Metal Conduit and IMC.
Size
(Inches)
Length A
(in/mm)
Support Weight
Lbs/Kg
Catalog Number
FH — Hanger Loops — With 5/8” diameter wireway
FHLM — Male
A
A
FHLM
1/2
3.88/98.6
3/4
4.13/104.9
350/157.5
FHLM-50
FHLM-75
FHLF — Female
FHLF
1/2
3.25/82.6
3/4
3.25/82.6
350/157.5
FHLF-50
FHLF-75
Lighting
FH — Hanger Hooks — With 5/8” diameter wireway, 3/8” jaw opening
FHHM — Male
A
A
3.88/98.6
4.13/104.9
200/90.0
FHHM-50
FHHM-75
FHHF — Female
1/2
3.25/82.6
3/4
3.25/82.6
200/90.0
FHHF-50
FHHF-75
FHHF
FHHCG—Gasketed Fixture Hanger Hook — With 5/8” wire opening, 3/8” jaw opening, safety screw — As FHHM’s above, with
internal grommet to prevent moisture and dirt entry
FHHCG — Male
A
1/2
4.25/108.0
3/4
4.25//108.0
75/34.0
FHHCG-3750-SS
FHHCG-3775-SS
FHSN — Conduit Suspension Hanger — With safety strap—clamps around rigid conduit or IMC —Has 3/8” jaw opening
A
1/2
3.13/79.5
3/4
3.25/82.6
1
3.38/85.9
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
FHSN-50
150/67.5
FHSN-75
FHSN-100
1419
Lighting: Flexible Fixture Hangers — Ordinary Location
FHHM
1/2
3/4
Flexible Fixture Hangers
Receptacle and Hook and Loop
UNILETS® for Use with Threaded Rigid Metal Conduit and IMC.
Applications
• Designed for suspension of HID, fluorescent and incandescent
lighting fixtures.
Features
• Permit quick disconnect and removal of fixture for
maintenance.
• Available in pendant or feed-thru.
• Available with matching cord set.
Standard Materials
• Malleable iron with steel cover
• Screws: stainless steel
Lighting: Flexible Fixture Hangers — Ordinary Location
Lighting
Standard Finishes
• Malleable iron parts: triple-coat—(1) zinc electroplate, (2)
chromate, and (3) epoxy powder coat
• Steel parts: zinc electroplate
GHPHP
GHPHT
GHPHP and GHPHT — Receptacle Hangers
Conduit Hub Size
(Inches)
Catalog Number
Voltage
Hubbell Plug
Pendant
Feed-Thru
Furnished with assembled FS box, EFHM, safety lock, receptacle, and steel cover. Supports 200 lbs/ 90.7kg.
8.5”
215.9mm
GHPHP
6.06”
153.9mm
3/4
120
L5-15P
GHPHP12
GHPHT12
3/4
208, 240
L6-15P
GHPHP24
GHPHT24
3/4
277
L7-15P
GHPHP27
GHPHT27
3/4
347
L37-20P
GHPHP34 V
GHPHT34 V
3/4
480
L8-20P
GHPHP48
GHPHT48
3/4
600
L9-20P
GHPHP60 V
GHPHT60 V
GHPHT
Cord Sets — With Loop —Supplied with 600 V, 90°C 3 conductor No. 16 SOW cable, locking plug and 3/4" FHLM loop
1420
Voltage
Amperes
2'/0.6 m Cord
3'/0.9 m Cord
4'/1.21 m Cord
120
15
G-HCPL-2-12
G-HCPL-3-12
G-HCPL-4-12
208, 240
15
G-HCPL-2-24
G-HCPL-3-24
G-HCPL-4-24
277
15
G-HCPL-2-27
G-HCPL-3-27
G-HCPL-4-27
347
20
G-HCPL-2-34 V
G-HCPL-3-34 V
G-HCPL-4-34 V
480
20
G-HCPL-2-48
G-HCPL-3-48
G-HCPL-4-48
600
20
G-HCPL-2-60 V
G-HCPL-3-60 V
G-HCPL-4-60 V
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
Power Hook for Industrial High Bay Luminaires
V
Furnished with Receptacle, Plug, 18" 16-3 SO Cord and Loop Fixture Hanger
Applications
• Designed for suspension of HID, fluorescent and incandescent
lighting fixtures.
Features
Lighting
• All hangers
— All fixture hangers protect fixture against wind and vibration
damage.
— Cushion type for added protection where lighting fixtures are
subjected to vibration.
• G-HBPH power hook for industrial luminaires
— Loop that suspends fixture cannot be removed until plug is
disconnected from power receptacle.
— 20 Amp plug, receptacle and cable are provided in all
voltages.
— Rotating plug after insertion locks plug in receptacle,
eliminating plug fall-out.
— Loop and hook provide flexible mounting, ideal in areas
where vibration is encountered.
Standard Materials
• Copperfree (4/10 of 1% max.) cast aluminum
Standard Finishes
Lighting: Flexible Fixture Hangers — Ordinary Location
• Powder coat epoxy
Certifications and Compliances
• CSA Approved
Size (Inches)
Voltage
Catalog Number
3/4
120
G-HBPH-120
3/4
208
G-HBPH-208
3/4
240
G-HBPH-240
3/4
277
G-HBPH-277
3/4
347
G-HBPH-347
3/4
480
G-HBPH-480
3/4
600
G-HBPH-600
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
1421
BKX Rigid Fixture Hangers V
UNILETS® for Use with Threaded Rigid Metal Conduit and IMC.
Class II, Division 1 and 2, Groups E, F, G
Class III,
Enclosure 4
Applications
• Designed for suspension of HID, fluorescent and incandescent
lighting fixtures.
Features
• All fixture hangers protect fixture against wind and vibration
damage.
• Cushion type for added protection where lighting fixtures are
subjected to vibration.
• Available in three depths.
• Accepts JB covers for ordinary location and AHG hangers for
Class II hazardous locations.
BKX Shallow Box
BKX Deep Box
Standard Materials
• Ferrous alloy and copperfree aluminum
Certifications and Compliances
Lighting: Flexible Fixture Hangers — Explosionproof
Lighting
• CSA Approved
1422
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
BKX Rigid Fixture Hangers V
UNILETS® for Use with Threaded Rigid Metal Conduit and IMC.
Class II, Division 1 and 2, Groups E, F, G
Class III,
Enclosure 4
Furnished with gasketed cover, four threaded conduit entries and 2 close-up plugs
Fixture Stem
Size (Inches)
Hub Size
(Inches)
Enclosure Only
Ferrous Alloy
Catalog Number
Enclosure Only
With Cover
Aluminum
Ferrous Alloy
With Cover
Aluminum
Shallow Box — 2-1/16
1/2
1/2
BKXS-1
BKXS-1A
BKXS-11
BKXS-11A
1/2
3/4
BKXS-2
BKXS-2A
BKXS-21
BKXS-21A
3/4
3/4
BKXS-2
BKXS-2A
BKXS-22
BKXS-22A
Medium Box — 2-11/16
1/2
1/2
BKXM-1
BKXM-1A
BKXM-11
BKXM-11A
1/2
3/4
BKXM-2
BKXM-2A
BKXM-21
BKXM-21A
1/2
1
BKXM-3
BKXM-3A
BKXM-31
BKXM-31A
3/4
3/4
BKXM-2
BKXM-2A
BKXM-22
BKXM-22A
3/4
1
BKXM-3
BKXM-3A
BKXM-32
BKXM-32A
1/2
1/2
BKXD-1
BKXD-1A
BKXD-11
BKXD-11A
1/2
3/4
BKXD-2
BKXD-2A
BKXD-21
BKXD-21A
Deep Box — 3-9/16
1
BKXD-3
BKXD-3A
BKXD-31
BKXD-31A
3/4
BKXD-2
BKXD-2A
BKXD-22
BKXD-22A
3/4
1
BKXD-3
BKXD-3A
BKXD-32
BKXD-32A
Lighting
1/2
3/4
Covers with Gasket Attached
—
—
CBK-1G
CBK-1GA
—
—
CBK-2G
CBK-2GA
Dimensions in Inches/Millimeters
Catalog Number
A
B
BKXS
1.31/33.3
1.50/38.1
BKXM
1.56/39.6
2.25/57.2
BKXD
1.56/39.6
3.00/76.2
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
1423
Lighting: Flexible Fixture Hangers — Explosionproof
1/2
3/4
CPU and EFHU Fixture Hangers
Explosionproof, Dust-Ignitionproof
UNILETS® for use with Threaded Metal Conduit.
Class I, Division 1 and 2,Groups C, D
Class II, Division 1 and 2, Groups E, F, G
Class III
Applications
• Fixture hangers and accessories for suspension of industrial
type HID, incandescent, and fluorescent lighting fixtures in
Class I, Class II, and Class III classified locations.
• Suitable for use in areas where moisture, dust and corrosive
atmospheres are present.
• CPU and EFHU, EFHC, have smooth, rounded integral bushing
in each hub to protect conductor insulation.
Lighting
Features
• Boxes have cast mounting lugs. Box and hub cover provide
a complete assembly for suspending lighting fixtures in
classified locations.
• CPU20 Hangers are used where fixture stem is less than 12”
long or with EXJF, ESD, or ESS where fixture stem is more than
12” long.
• EFHU Flexible Hangers meet NEC Sec. 501 requirement for
flexible suspension where fixture stem is more than 12” long.
• Cushion design protects against vibration, and swivel action
(any direction up to 15° from vertical) protects fixture if
accidentally struck.
• EFHU Flexible Cushion Hangers available in three spring ranges
to support fixture weights of 12 to 48 lbs / 5.4kg to 21.8kg and
48 to 120 lbs / 21.8kg to 54.4kg.
• CB205 Connection Block available for connecting all wires
without splices.
• Ground-joint mating surfaces assure flame-tight fit.
• Hanger has setscrew in stem hub to prevent fixture stem
from turning.
CPU
EFHU
Illustrated Features
Standard Materials
• CPU and EFHU: malleable iron or copperfree (4/10 of 1% max.
aluminum
• EFHU flexible hanger: brass fixture stem hub assembly
Lighting: Flexible Fixture Hangers — Explosionproof
Standard Finishes
• CPU20 rigid fixture hangers body: triple-coat – 1) zinc
electroplate, (2) chromate, and (3) epoxy powder coat
• CPU20 rigid fixture hangers cover: zinc electroplate and clear
chromate
• Separate CPU20 covers: zinc electroplate and clear chromate.
• EFHU flexible cushion fixture hangers: triple-coat – 1) zinc
electroplate, (2) chromate, and (3) epoxy powder coat
Certifications and Compliances
• UL Listed: E10444
• UL Standard: 886
• Suitable for Class I, Division 1 and 2, if installed in compliance
with NEC 501-9(a)(b) and for Class II, Division 1 and 2, if in
compliance with NEC 502-11(a)(b)
®
1424
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
CPU and EFHU Fixture Hangers
Explosionproof, Dust-Ignitionproof
UNILETS® for use with Threaded Metal Conduit.
Class I, Division 1 and 2,Groups C, D
Class II, Division 1 and 2, Groups E, F, G
Class III
NEC Catalog Number
Conduit Size
(Inches)
Fixture Stem
Size (Inches)
Support Weight
(lbs/kg)
Malleable Iron
CSA Catalog Number
Malleable Iron
V
Aluminum
CPU Fixture Hangers — Non-Flexible Type — Form 20
Furnished with cast mounting lugs, four threaded universal 3/4” hubs, four 3/4”
to 1/2” reducers, and three 1/2” close-up plugs.
1/2 or 3/4
1/2
250/112.5
CPU20-50
CPU20-50CN
CPU20-50ACN
1/2 or 3/4
3/4
250/112.5
CPU20-75
CPU20-75CN
CPU20-75ACN
EFHU Fixture Hangers — Flexible Cushion Type — Form 20
Furnished with cast mounting lugs, four threaded universal 3/4” hubs, four 3/4”
to 1/2” reducers, and three 1/2” close-up plugs.
1/2 or 3/4
3/4
1/2 or 3/4
3/4
12 to 48/
EFHU75-48
EFHU75-48CN
—
21.8 to 54.0
EFHU75-120
EFHU75-120CN
—
1/2
250/112.5
CPSK20-50
CPSK20-50ACN CPSK20-50ACN
3/4
250/112.5
CPSK20-75
CPSK20-75ACN CPSK20-75ACN
5.4 to 21.6
48 to 120/
Lighting
CPU Fixture Hanger Covers — Non-Flexible Type — Form 20
Furnished with screws.
Lighting: Flexible Fixture Hangers — Explosionproof
EFHU Fixture Hanger Covers — Flexible Cushion Type — Form 20
Furnished with screws. 3/4” to 1/2” reducer supplied for 1/2” fixture stem.
3/4
12 to 48/
5.4 to 21.6
3/4
EFH75-48
EFH75-48CN
—
EFH75-120
EFH75-120CN
—
48 to 120/
21.8 to 54.0
CPU and EFHU Connection Block Accessory
Mounts directly to drilled and tapped pads in CPU and EFHU hangers.
Phenolic, with fastening strap and mounting screws.
5-Wire. 20-Amp, 300 V Max.
CB205
CB205CN
CB205ACN
2.88"/
73.2 mm
CB205
CB205CN V
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
1425
CPU and EFHU Fixture Hangers Dimensions
Explosionproof, Dust-Ignitionproof
UNILETS® for use with Threaded Metal Conduit.
CPU50 and CPU75 Rigid Fixture Hanger
10-32 Thd.
.34"/
8.6 mm
5.56"/
141.2 mm
.25"/
6.4 mm
.75"/19.1 mm
2.00"/
50.8 mm
0.28"/
7.1 mm Dia.
2 Holes
.25"/6.4 mm - 14 Thd.
2.88"/
73.2 mm
3.69"/
93.7 mm
6.38"/
162.1mm
3.81"/
96.8 mm
4.63"/
117.6 mm
7.38"/187.5 mm
Lighting
EFHU Flexible Cushion Fixture Hanger
.75"/19.1 mm
.25"/6.4 mm
5.56"/
141.2 mm
0.28"/
7.1 mm Dia.
2 Holes
.25"/6.4mm-20 Thd.
2.00"/
50.8 mm
Lighting: Flexible Fixture Hangers — Explosionproof
2.19"/55.6 mm
6.38"/
162.1mm
7.75"/
196.9 mm
7.38"/187.5 mm
.88"/
22.4 mm
1426
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
Flexible Fixture Hangers, EXJF Couplings, ESD and ESS Swivels
Explosionproof, Dust-Ignitionproof
UNILETS® for use with Threaded Metal Conduit. For Use with Rigid Fixture Hangers Where Fixture Stem is More Than 12”/304.8 mm Long.
Class I, Division 1 and 2, Groups A, B, C, D
Class II, Division 1 and 2, Groups E, F, G
Class III
Applications
• Fixture hangers and accessories for suspension of industrial
type HID, incandescent, and fluorescent lighting fixtures in
Class I, Class II, and Class III classified locations.
• Suitable for use in areas where moisture, dust and corrosive
atmospheres are present.
EXJF
Features
• EYJF Hanger Coupling
— Meets NEC Sec. 501 requirement for flexible suspension
where fixture stem is more than 12”/304.8 mm long.
— Watertight construction.
— Convenient method for attaching explosionproof lighting
fixtures to non-flexible hangers.
— Allows free swing of lighting fixture in any direction. Absorbs
shock, prevents damage to conduit and connections.
— Assures plumb hanging of fixture.
— Both end fittings are female with removable male close
nipples. To make union end-coupling, remove nipple from either
end and thread in a 1/2” or 3/4” UNY Union.
— Female end fittings have setscrews with screwdriver slot to
allow locking of conduit. Prevents turning of fixture stem and
nipple.
• ESS and ESD swivels for use with rigid fixture hangers where
fixture stem is more than 12”/304.8 mm long.
Standard Materials
ESD
ESS
Illustrated Features
Lighting
• EXJF flexible hanger couplings: outer bronze braid, inner brass
core with insulating liner and brass end fittings.
• ESD and ESS swivels: malleable iron.
Standard Finishes
• EXJF flexible couplings: natural finish.
• ESD and ESS swivels: triple-coat – 1) zinc electroplate, (2)
chromate, and (3) epoxy powder coat.
Lighting: Flexible Fixture Hangers — Explosionproof
Options
• EXJF available in stainless steel, add -SS to catalog number.
Certifications and Compliances
•
•
•
•
UL Listed: E10444
UL Standard: 886
CSA Certified: 065182
Suitable for Class I, Division 1 and 2, if installed in compliance
with NEC 501-9(a)(b) and for Class II, Division 1 and 2, if in
compliance with NEC 502-11(a)(b)
Related Products
• For unions, see Fittings Section.
Shaded area on the following page indicates items suitable for Class I, Groups A and B in addition to Class I, Groups C and D; Class II, Groups E, F and G;
and Class III.
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
1427
Flexible Fixture Hangers, EXJF Couplings, ESD and ESS Swivels
Explosionproof, Dust-Ignitionproof
UNILETS® for use with Threaded Metal Conduit. For Use with Rigid Fixture Hangers Where Fixture Stem is More Than 12”/304.8 mm Long.
Class I, Division 1 and 2, Groups A, B, C, D
Class II, Division 1 and 2, Groups E, F, G
Class III
Size
(Inches)
Inches/Millimeters
Flexible Length
Catalog
Number
Overall Length
EXJF Flexible Fixture Hanger ➊
Lighting
Raintight construction. Supplied with two female hubs, each with a removable close nipple. Can
be used to make male to male, female to male or female to female. Setscrew with screwdriver slot
allows locking of conduit—prevents fixture stem from turning.
1/2
4.00/101.6
11.06/ 28.1
EXJF14
3/4
4.00/101.6
11.06/ 28.1
EXJF24
1/2
4.00/101.6
11.06/ 28.1
EXJF16
3/4
4.00/101.6
11.06/ 28.1
EXJF26
1/2
4.00/101.6
11.06/ 28.1
EXJF18
3/4
4.00/101.6
11.06/ 28.1
EXJF28
1/2
4.00/101.6
11.06/ 28.1
EXJF110
3/4
4.00/101.6
11.06/ 28.1
EXJF210
1/2
4.00/101.6
11.06/ 28.1
EXJF112
3/4
4.00/101.6
11.06/ 28.1
EXJF212
1/2
4.00/101.6
11.06/ 28.1
EXJF115
3/4
4.00/101.6
11.06/ 28.1
EXJF215
1/2
4.00/101.6
11.06/ 28.1
EXJF118
3/4
4.00/101.6
11.06/ 28.1
EXJF218
Swivel Hangers — Setscrew with screwdriver slot allows locking of conduit — Prevents fixture stem from turning
ESD Swivel
Lighting: Flexible Fixture Hangers — Explosionproof
15° swivel from center and full 360° free swing.
1/2
ESD50 ➋
3/4
ESD75 ➋
ESS Swivel
15° swivel from center.
1/2
ESS50 ➋
3/4
ESS75 ➋
➊ Available in stainless steel. Add suffix -SS to catalog number. Consult your local sales representative.
➋ Not CSA Certified.
Shaded area indicates items suitable for Class I, Groups A and B in addition to Class I, Groups C and D; Class II, Groups E, F and G; and Class III.
1428
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
Flexible Fixture Hangers, EXJF Couplings, ESD and ESS Swivel Dimensions
Explosionproof, Dust-Ignitionproof
UNILETS® for use with Threaded Metal Conduit. For Use with Rigid Fixture Hangers Where Fixture Stem is More Than 12”/304.8 mm Long.
ESS Swivel
ESD Swivel
3.00"/
76.2 mm
3.00"/
76.2 mm
3.94"/
100.1 mm
3.31"/
84.1 mm
1.88"/
47.8 mm
2.31"/
58.7 mm
3.00"/
76.2 mm
EXJF
Lighting
A
Dimensions in Inches/Millimeters
B
C
1/2
3.38/85.9
1.88/47.8
1.44/ 36.6
3/4
3.38/85.9
1.88/47.8
1.75/44.5
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
Lighting: Flexible Fixture Hangers — Explosionproof
Size
Inches
1429
EFHC and EFHCA Fixture Hangers and Accessories
Explosionproof, Dust-Ignitionproof
UNILETS® for use with Threaded Metal Conduit.
Class I, Division 1 and 2, Groups A*, B, C, D
Class II, Division 1 and 2, Groups E, F, G
Class III
Applications
• Fixture hangers and accessories for suspension of industrial
type HID, incandescent, and fluorescent lighting fixtures in
Class I, Class II, and Class III classified locations.
• Suitable for use in areas where moisture, dust and corrosive
atmospheres are present.
• EFHC and EFHCA hangers have smooth, rounded integral
bushing in each hub to protect conductor insulation.
Features
• EFHC and EFHCA Fixture Hangers are used where fixture stem
is less than 12”/304.8 mm long or with EXJF, ESD, or ESS where
fixture stem is more than 12”/304.8 mm long.
• Raintight when used with O-Ring.
• Provided with threaded removable cover for convenience in
pulling or splicing conductors.
• Mounting strap available for fastening EFHC or EFHCA to a
mounting surface.
• CB202 connection block available for convenience in
connecting line and fixture wires without splices.
• Hanger has setscrew in stem hub to prevent fixture stem
from turning.
EFHC
EFHCA
Illustrated Features
Lighting
Standard Materials
• EFHC and EFHCA fixture hanger body: malleable iron
• EFHC and EFHCA fixture cover: copperfree (4/10 of 1% max.)
aluminum
• EFHC and EFHCA mounting strap and LC locking coupling:
steel
Standard Finishes
Lighting: Flexible Fixture Hangers — Explosionproof
• EFHC and EFHCA fixture hanger body: triple-coat – 1) zinc
electroplate, (2) chromate, and (3) epoxy powder coat
• EFHC and EFHCA fixture hanger cover: epoxy powder coat
• EFHC/EFHCA mounting strap and LC locking coupling: zinc
electroplate
Certifications and Compliances
•
•
•
•
UL Listed: E10444
UL Standard: 886
CSA Certified: 025875
Suitable for Class I, Division 1 and 2, if installed in compliance
with NEC 501-9(a)(b) and for Class II, Division 1 and 2, if in
compliance with NEC 502-11(a)(b)
Shaded area on following page indicates items suitable for Class I, Groups B, C and D; Class II, Groups E, F and G; and Class III. Sealing fitting must be
installed adjacent to enclosure for all conduits for Group B location (EFHC Series).
* Suitable for Class I, Groups A, B, C, D.
1430
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
EFHC and EFHCA Fixture Hangers and Accessories
Explosionproof, Dust-Ignitionproof
UNILETS® for use with Threaded Metal Conduit.
Class I, Division 1 and 2, Groups A*, B, C, D
Class II, Division 1 and 2, Groups E, F, G
Class III
Conduit Size (Inches)
Fixture Stem Size (Inches)
Catalog Number
EFHC Fixture Hanger
Class I, Groups B, C and D
Class II, Groups E, F and G
Class III
3/4
1/2
EFHC755
3/4
3/4
EFHC7575
1
1/2
EFHC1050
1
3/4
EFHC1075
EFHCA Fixture Hanger
Class I, Groups A*, B, C and D
Class II, Groups E, F and G
Class III
3/4
1/2
EFHCA7550 *
3/4
3/4
EFHCA7575 *
1
1/2
EFHCA1050 *
1
3/4
EFHCA1075 *
EFHC and EFHCA Connection Block Accessory – Porcelain
Lighting
Designed to fit in hanger without fastening.
2 Wire, 20 Amp 277 Volt
Maximum Wire Size
Two No. 10 AWG large terminal
Two No. 14 AWG small terminal
CB202
EFHC and EFHCA Steel Mounting Strap
For fastening EFHC or EFHCA to a mounting surface.
Add suffix S
Dimensions
EFHCA and EFHC Fixture Hangers
0.13"/
3.3 mm
5.69"/
144.5 mm
FHS Rigid Support
4.31"/
109.5 mm
0.94"/
23.9 mm
4.56"/
115.8 mm
3.25"/
82.6 mm
1.13"/
28.7 mm
5.31"/
134.9 mm
EFHC:
2.81"/
71.4 mm
2.25"/
57.2 mm
.34"/
8.6 mm Dia.
2 Holes
0.25"/
6.4 mm
1.75"/
44.5 mm
3.31"/
84.1 mm
EFHC:
3.13"/
79.5 mm
3.75"/
95.3 mm
0.34"/
8.6 mm Dia.
0.69"/
17.5 mm
* Suitable for Class I, Groups A, B, C and D.
Shaded area indicates items suitable for Class I, Groups B, C and D; Class II, Groups E, F and G; and Class III.
Sealing fitting must be installed adjacent to enclosure for all conduits for Group B location (EFHC Series).
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
1431
Lighting: Flexible Fixture Hangers — Explosionproof
Add suffix S to above EFHCA or EFHC catalog numbers.
GRF Conduit Outlet Boxes and Fixture Hanger Covers and Canopies
Explosionproof, Dust-Ignitionproof
UNILETS® for use with Threaded Metal Conduit.
Class I, Division 1 and 2, Groups C, D
Class II, Division 1 and 2, Groups E, F, G
Class III
Applications
• Fixture hangers and accessories for suspension of industrial
type HID, incandescent, and fluorescent lighting fixtures in
Class I, Class II, and Class III classified locations.
• Suitable for use in areas where moisture, dust and corrosive
atmospheres are present.
• GRF conduit outlet boxes have smooth, rounded integral
bushing in each hub to protect conductor insulation.
Features
• GRF conduit outlet box with fixture hanger canopy or cover is
used where fixture stem is less than 12”/304.8 mm long or with
EXJF, ESD, or ESS where fixture stem is more than 12” long.
• Raintight when used with O-Ring.
• For use with hub cover or canopy. canopy has threaded cover
opening for convenience in splicing conductors.
• Cover and canopy hubs have set-screws with screwdriver slots
to allow locking of conduit. Prevents fixture stem form turning.
GRFC
GRF Canopy
Illustrated Features
Standard Materials
• Malleable iron or copperfree (4/10 of 1% max.) aluminum
Standard Finishes
• Bodies: triple-coat – 1) zinc electroplate; (2) chromate, and (3)
epoxy powder coat
• Covers and canopies: zinc electroplate and clear chromate
Lighting: Flexible Fixture Hangers — Explosionproof
Lighting
Certifications and Compliances
• UL Standard: 886
• Suitable for Class I, Division 1 and 2, if installed in compliance
with NEC 501-9(a)(b) and for Class II, Division 1 and 2, if in
compliance with NEC 502-11(a)(b)
Dimensions in Inches/Millimeters
GRF Conduit Outlet Box
GRF Canopy
2.31"/
58.7 mm
.38"/
9.7 mm
5.38"/
136.7 mm
3.38"/
85.9 mm
.81"/
20.6 mm
4.75"/
120.7 mm
3.81"/
96.8 mm
3.38"/
85.9 mm
3.88"/
98.6 mm
3.00"/
76.2 mm
1.50"/
38.1 mm
2.13"/
54.1 mm
3.81"/
96.8 mm
.38"/
9.7 mm
1432
.56"/
14.2 mm
1.19"/
30.2 mm
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
GRF Conduit Outlet Boxes and Fixture Hanger Covers and Canopies
Explosionproof, Dust-Ignitionproof
UNILETS® for use with Threaded Metal Conduit.
Class I, Division 1 and 2, Groups C, D
Class II, Division 1 and 2, Groups E, F, G
Class III
NEC Catalog Number
Conduit Size
(Inches)
Fixture Stem Size
(Inches)
Malleable Iron
CSA Catalog Number
Aluminum
V
Malleable Iron
GRF Flanged Conduit Outlet Boxes — Form 1, Less Cover — For use with GRF fixture hanger canopies and covers below — Nominal
diameter of cover opening is 3-3/8” — Furnished with threaded hubs and ground screw — Flange has four 3/8” mounting slots
GRFC-50LC
—
GRFC-50LCCN
3/4
GRFC-75LC
—
GRFC-75LCCN
1
GRFC-100LC
—
GRFC-100LCCN
1/2
GRFL-50LC
—
GRFL-50LCCN
3/4
GRFL-75LC
—
GRFL-75LCCN
1
GRFL-100LC
—
GRFL-100LCCN
1/2
GRFT-50LC
—
GRFT-50LCCN
3/4
GRFT-75LC
—
GRFT-75LCCN
1
GRFT-100LC
—
GRFT-100LCCN
1/2
GRFX-50LC
—
GRFX-50LCCN
3/4
GRFX-75LC
GRFX-50ALCCN
GRFX-75LCCN
1
GRFX-100LC
GRFX-75ALCCN
GRFX-100LCN
Lighting
1/2
GRF Fixture Covers – Form 1 — Furnished with external threads for attachment to GRF mounting box above
Threaded Hub Cover
GRK-50
—
GRK-50CN
3/4
GRK-75
—
GRK-75CN
3/4
GRK-75U
—
GRK-75UCN
Union Hub Cover
GRF Fixture Canopies – Form 1 — Furnished with external threads for attachment to GRF mounting box above — Threaded cover
opening on side for convenience in splicing
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
1/2
GRK-50C
—
GRK-50CCN
3/4
GRK-75C
—
GRK-75CCN
1
GRK-100C
—
GRK-100CCN
1433
Lighting: Flexible Fixture Hangers — Explosionproof
1/2
Fixture Hanger Bracket and Accessories
UNILETS® for use with Threaded Metal Conduit.
NPT Size (Inches)
Support Weight (lbs/kg)
Catalog Number
Fixture Hanger Brackets
Suitable for use with fixtures with 3/4-14 NPT conduit openings or hubs. Mounts directly to ceiling or
wall separately from conduit system. Catalog number includes two brackets and two hexhead bolts.
Iron with gray epoxy finish.
3/4
200/90.0
Ceiling Mount
Projects light downward (90°).
Shown mounted to Appleton
AH260-118 explosionproof
fluorescent lighting fixture.
FHS1
Wall Mount
Projects light at 45° angle. Shown
mounted to Appleton AH260-118
explosionproof fluorescent lighting
fixture.
Safety Support Hooks and Rigid Support for Dummy Side of Lighting Fixtures
Complete assembly includes two hooks and one rigid support. Each hook supplied with a screw for
closing 3/8” jaw opening. Rigid Support straddles max. 1-1/4” conduit. (Chain shown in installation
view not furnished.)
Lighting: Flexible Fixture Hangers — Explosionproof
Lighting
3/4
200/90.0
AC-KT
LC Steel Locking Couplings
Setscrews with Allen head fasten on outside of hub and fixture stem. Prevents fixture stem from turning
in hubs not normally supplied with setscrews. 3/4” fixture stem.
3/4
—
SLC75
1
—
SLC1075
200/90.0
EFHM-50
Safety Support Hooks for Dummy Side of Lighting Fixtures
Supplied with screw for closing 3/8” jaw opening.
Male
1/2
EFHM-75
3/4
Female
1/2
200/90.0
EFHF-50
EFHF-75
3/4
Rigid Support for Fluorescent Lighting Fixtures (Dummy Side)
Will straddle max. 1-1/4” conduit.
1/2 and 3/4
1434
350/157.5
FHS5075
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
Fixture Hanger Bracket and Accessories
UNILETS® for use with Threaded Metal Conduit.
Dimensions of FHS1 Fixture Hanger Bracket
2.50"/
63.5 mm
3/4 - 14 Tapered
Pipe Thread
2.50"/63.5 mm
0.19"/4.8 mm R18
1.25"/
31.8 mm
1.25"/31.8 mm
1.13"/28.7 mm Dia. Hole
1.69"/42.9 mm
6.38"/162.1 mm
1.50"/
3.81 mm
.67"/
17.0 mm
1.00"/
25.4 mm
0.5"/12.7 mm R
.67"/
17.0 mm
1.25"/31.8 mm
2.50"/
63.5 mm
.31"/7.9 mm
Lighting
Lighting: Flexible Fixture Hangers — Explosionproof
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
1435
HID Temporary Lighting
Designed and Packaged for Quick Installation
Applications
• More and more contractors are using temporary HID fixtures to
light their work sites. Instead of modifying Low-Bay fixtures for
this application, McGill’s HID Temporary Lighting allows them to
buy something faster and easier.
Lighting
Lighting: McGill Temporary
Features
• 400 W Pulse Start Metal Halide lamp provides over 6 foot/1.8
meters candles of illumination at a 20 ft./6.1 meter mounting
height.
• McGill offers lighting layouts to conform with OSHA
requirements for light output.
• Type “O” lamp and mogul socket complies with NEC 2008
Article 410.13(F)(5) and ANSI C78.387.
• Quick-attach durable 10”/254 mm welded wire guard mounts
directly to the body to protect lamp and lampholder from
accidental impact.
• Fixture is factory wired at 120 Volt, but can be rewired internally
for other voltage settings.
• 3'/0.9 m cord with 5-15P molded plug on end.
• Compact size for easy handling.
• Low-profile fixture design keeps it up and out of the way of
activity below.
• High light output and long lamp life.
• Open-air ballast for cooler operation.
• Hook with locking feature.
• (2) 3/4”/19.1 mm knock-outs for conduit access.
• Single durable package design makes it easier for distributors to
stock and more organized for contractors on the job site.
• Quick and easy to assemble.
• Optional bottom trap available.
Shown with optional bottom trap
Illustrated Feature
Spring-lock hook allows
contractors to mount the
unit in seconds, without
the need for tools.
Standard Materials
• Enclosure: Heavy-duty steel with powder coated finish
• Lamp: 400 Watt Pulse Start Metal Halide: O-Type, BT37 Clear,
EX39 (Exclusionary Mogul Base)
• Multi-Tap ballast: 120, 208, 240, 277 Volt: Factory wired at 120
Volt
• Power cord: 3 FT/0.9 M, 18/3 SJTW, 120 Volt, 15 Amp cord
complete with NEMA 5-15 molded plug
• Lamp guard: 11 ga. white painted steel
• Mounting hook: 11 ga. steel
Dimensions in Inches/Millimeters
4.26"/108.2 mm
3.52"/
89.4 mm
Certifications and Compliances
0.12"/
3.0 mm
2.21"/
0.7 mm
8.0"/2.4 mm
3 ft/0.9 m
• UL and cUL Listed: E196293
• UL Standard: UL 1598
• Suitable for damp locations
Options
• Optional bottom trap available
Catalog Number
TL40PMTO
Bottom Guard Trap
TLTRAPW
Replacement Lamp Guard
TLGUARDW
Replacement Lamp:
400 W PSMH, O-Type, BT37 Clear, EX39
GMP400BUPS
1436
11.76"/3.6 mm
400 W Fixture with Guard
9.25"/2.8 mm
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
String-O-Lights
Low Cost Temporary Lighting
OPEN CONDUCTOR
Applications
• McGill offers a variety of temporary job site lighting systems,
from reusable, low cost cable versions to an assortment of open
conductor styles.
Features
Flat Wire Cable Style
Standard Materials
FLATWIRE
Illustrated Features
Easy-Open Cages
• Cages: yellow plastic
•
MOLDED CABLE
Certification and Compliance
Molded Cable Version
— UL Listed: E88103
— UL Standard: 1088
— Meets OSHA requirements
— CSA Certified: LL89639 V
— CSA Standard: C22.2 No. 12
Lighting: McGill Temporary
• They are available in 50’ to 200’/15.2 to 61 meters lengths of 2and 3-conductor and 12 and 14 gauge wire with 5 to 10 cage/
socket assemblies.
• Brass sockets are enclosed in weather-resistant molded PVC,
and plastic connectors provide greater reliability.
• Packaging provides tangle-free, on-the-job handling and
installation.
• Easy-open cages snap open and closed for faster installation
without tools and easy lamp replacements.
• Non-corrosive cages are fastened to sockets by a non-corrosive
collar and accommodate up to 200 Watt bulbs.
• Cable styles meet 2008 NEC requirements.
• Convenient, economical temporary lighting.
• 110’/30.5 m messenger wire available to support string where
needed.
• Fully assembled; ready for installation.
• Weather-resistant sockets.
• All parts sold separately.
Packaging
No. of Socket
Cages/ Spacing
Sockets Ft/M
Catalog Numbers
for A-23 Bulb
for PS-30 Bulb
Molded Cable Styles — UL Listed
12/2-SJTW cable with plug/boot on one end and connector/cap on other end
100/30.5
10
10/3.0
2252-0018
—
12/2-SJTW cable
100/30.5
10
10/3.0
2252-0019
—
12/2-STW extra hard usage cable with weather protected plug/boot
100/30.5
10
10/3.0
2252-5007 V
—
12/3-SJTW cable with 5-15 plug/boot on one end and connector/cap on other end
100/30.5
10
10/3.0
2252-0026
—
12/3-SJTW cable
100/30.5
10
10/3.0
2252-0027
—
14/2-SJTW cable
100/30.5
10
10/3.0
2252-0007
2252-0009
14/2-SJTW cable with plug/protective rubber boot on one end
100/30.5
10
10/3.0
2252-0012
2252-0013
14/2-SJTW cable
50/15.2
5
10/3.0
2252-0031 *
14/3-SJTW cable
100/30.5
10
10/3.0
2252-0014
2252-0015
14/3-SJTW cable with 5-15 plug/boot on one end and connector/cap on other end
100/30.5
10
10/3.0
2252-0024
2252-0025
14/3-SJTW cable
50/15.2
5
10/3.0
2252-0034 *
—
—
* Contact Technical Service for UL data
V CSA Certification only.
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
1437
Lighting
Length
Ft/M
String-O-Lights
Low Cost Temporary Lighting
Length
Ft/M
No. of
Cages/
Sockets
Socket
Spacing
Ft/M
Catalog Number
for A-23 Bulb
for PS-30 Bulb
100/30.5
10
10/3.0
2252-0035
—
Flat Wire Styles
14/2 Flat wire cable
14/2 Flat wire cable
50/15.2
5
10/3.0
2252-0038
—
14/2 Flat wire cable
200/61.0
10
20/6.1
2252-0043
—
14/2 Flat wire cable with 1-15P plug on one end
100/30.5
10
10/3.0
2252-0040
—
14/2 Flat wire cable with 1-15P plug on one end
50/15.2
5
10/3.0
2252-0041
—
14/2 Flat wire cable with 1-15P plug on one end
200/61.0
10
20/6.1
2252-0044
—
2-conductor, 14 gauge wire
100/30.5
10
10/3.0
2252-4040
2252-4060
2-conductor, 14 gauge wire, right-hand screw shells
100/30.5
10
10/3.0
2252-1010
2252-2020
2-conductor, 14 gauge wire, left-hand screw shells
100/30.5
10
10/3.0
2253-1010
2253-2020
Flat Wire Styles with Plug
Lighting: McGill Temporary
Open Conductor Styles
2-conductor, 14 gauge wire
50/15.2
5
10/3.0
2252-0006
—
2-conductor, 14 gauge wire
200/61.0
10
20/6.1
2252-0008
2252-2008
Accessories and Replacement Parts
Catalog Number
2252-1025
Hangers (for open conductor styles)
Cages
Catalog Number
for A-23 Bulb
for PS-30 Bulb
Single plastic replacement cage only
MCG2250
—
Single plastic replacement cage with screw collar
2250-S
2255
Single plastic replacement cage with right-hand socket assembly and hanger
2252
2256
Single plastic replacement cage with left-hand socket assembly and hanger
2253
—
Single plastic replacement cage with hanger (no socket)
2254
—
2259
—
Lighting
For use with McGill String-O-Lights
For use with most types of Lampholders
Single plastic cage only
Socket/Wire Sets
Catalog Number
Weather-resistant 600 Watt/250 Volt, 4-1/2”/114.3 mm leads of 14 gauge wire, vulcanized, pigtail socket;
right-hand thread
4017
Weather-resistant 600 Watt/250 Volt, 4-1/2”/114.3 mm leads of 14 gauge wire, vulcanized, pigtail socket;
left-hand thread
4018
Messenger wire: 110’/30.5 meters 3/32”/2.3 mm dia. 7 x 7 stranded galvanized aircraft cable
2251
1438
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
7000 Series Industrial Extension Lights
Rubber Handle without Receptacle
Features
• 7000 Series extension lights resist damage and deterioration.
• Open-end or NO-ROL closed-end cages of extra-heavy,
electrically welded, wire accommodate up to 200 Watt bulbs.
• Ideal for use where safety codes prohibit outlets in handles.
• Easy relamping cage.
• Internal strain relief withstands 30 lb/9.1 kg. pull test.
• All-weather cords with molded plugs.
• Long-life Levolier™ switch mechanism in handle with protective
thumb guard.
Standard Materials
• Cage: 10 gauge steel wire
• Cord: thermoplastic
• Handle: yellow, grease-resistant, high quality rubber
7000-SG
7001-SRG ➋
7025-SRG
7000-RIG
Options
• 15 Amp, 120 Volt CSA Certified versions available. Items
available in a CSA version will be marked with a V. Add the
prefix C to the beginning of the catalog number.
Certifications and Compliances ➊
UL Listed (with cord): E59071
UL Listed (without cord): E59054
UL Standard: 153
Meets OSHA requirements
CSA Certified (with cord): LL89639 V
CSA Certified (without cord): LL56247 V
CSA Standard: C22.2 No. 12
Lighting: McGill Temporary
•
•
•
•
•
•
•
Lighting
7999-RGH
➊ 100 Watt Maximum for UL Listing and CSA Certification.
➋ Not UL Listed or CSA Certified.
V CSA Certification only.
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
1439
7000 Series Industrial Extension Lights
Rubber Handle without Receptacle
with out Cord
Catalog Numbers
with 1'/ 0.3m
with 25’/7.6m
16/3-SJTW Cord
16/3-SJTW Cord
with 50’/15.2m
16/3-SJTW Cord
Closed-End Extension Lights
Handle and cage
7000-G
—
7025-G
7050-G
Handle and cage with reflector
7000-RG
—
7025-RG
7050-RG
Handle and cage with switch
7000-SG
—
7025-SG
7050-SG
Handle and cage with switch and reflector
7000-SRG
7025-SRG
7050-SRG
—
7012-SRG ➊
—
7025-SRG-GFCI
Insulated cage, reflector (100 Watt max.)
7000-RIG
—
7025-RIG
7050-RIG
Non-metallic cage, reflector (100 Watt max.)
7999-RGH
—
7925-RGH
7950-RGH
6229-1 ➋
6229-2 ➋
Handle and cage with switch and reflector and GFCI
—
Replacement Cord Sets
Lighting: McGill Temporary
Cord set with molded plugs
Catalog Number ➋
for 60-100 Watt
for 200 Watt
Open-End Extension Lights (without cord)
7001-G
Handle and cage
7002-G
Handle and cage with reflector
7001-RG
7002-RG
Handle and cage with switch
7001-SG
7002-SG
Handle and cage with switch and reflector
7001-SRG
7002-SRG
Accessories and Replacement Parts
Catalog Number
With Out Reflector
With Reflector
Lighting
Cages
Closed-end cage for 7000
8171
8170
Open-end cage (100 Watt lamp max.)
8133
8162
Open-end cage (200 Watt lamp max.)
8335-2
8336
Closed-end vinyl insulated cage (100 Watt A-21)
08171
08170
Open-end vinyl insulated cage (100 Watt lamp max.)
—
08162
Open-end vinyl insulated cage (200 Watt lamp max.)
—
08336
Non-metallic cage for 7999
—
8224
Catalog Number
Catalog Number
With Out Switch
With Switch
Handles and Sockets
Handle for 7000, 7001, 7002
—
6403
6404-1
Handle and socket for 7000, 7001, 7002
—
8959
8950
Socket for 7000, 7001, 7002
—
4015
4005
9232
—
Grounding clamp
—
➊ UL Listed for cord reel usage only.
➋ Not UL Listed.
1440
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
7000 Series Industrial Extension Lights V
CSA Certification Only. Rubber Handle without Receptacle
with out Cord
Catalog Numbers
with 1'/0.3 m
with 25’/7.6 m
16/3-SJTW Cord
16/3-SJTW Cord
with 50’/15.2 m
16/3-SJTW Cord
Closed-End Extension Lights
Handle and cage
C7000-G
—
C7025-G
C7050-G
Handle and cage with reflector
C7000-RG
—
C7025-RG
C7050-RG
Handle and cage with switch
C7000-SG
—
C7025-SG
C7050-SG
Handle and cage with switch and reflector
C7000-SRG
C7012-SRG ➊
C7025-SRG
C7050-SRG
Insulated cage, reflector (100 Watt max.)
C7000-RIG
—
C7025-RIG
C7050-RIG
Non-metallic cage, reflector (100 Watt max.)
C7999-RGH
—
C7925-RGH
C7950-RGH
C6229-1 ➋
C6229-2 ➋
Replacement Cord Sets
Cord set with molded plugs
Catalog Number ➋
for 60-100 Watt
for 200 Watt
Handle and cage
C7001-G
C7002-G
Handle and cage with reflector
C7001-RG
C7002-RG
Handle and cage with switch
C7001-SG
C7002-SG
Handle and cage with switch and reflector
C7001-SRG
C7002-SRG
Accessories and Replacement Parts
Catalog Number
With Out Reflector
With Reflector
Lighting: McGill Temporary
Open-End Extension Lights (without cord)
Cages
8171
Closed-end cage for 7000
8170
8133
8162
8335-2
8336
Closed-end vinyl insulated cage (100 Watt A-21)
08171
08170
Open-end vinyl insulated cage (100 Watt lamp max.)
—
08162
Open-end vinyl insulated cage (200 Watt lamp max.)
—
08336
Non-metallic cage for 7999
—
8224
Lighting
Open-end cage (100 Watt lamp max.)
Open-end cage (200 Watt lamp max.)
Catalog Number
With Out Switch
With Switch
Handles and Sockets
Handle for 7000, 7001, 7002
—
6403
6404-1
Handle and socket for 7000, 7001, 7002
—
8959
8950
—
4015
4005
9232
—
Socket for 7000, 7001, 7002
Grounding clamp
—
➊ CSA Listed for cord reel usage only.
➋ Not CSA Listed.
V CSA Certification only.
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
1441
7000-38 Series Industrial Extension Lights
For PAR-38 Lamps
Applications
• These extension lights are ideal for temporary flood lighting,
railroad car inspections, spot light inspecting of the internal
conditions of large well pipes, and other applications requiring
intense lighting.
Features
• 7000 Series extension lights resist damage and deterioration.
• Open-end of extra-heavy, electrically welded, wire
accommodates up to 200 Watt bulbs.
• Ideal for use where safety codes prohibit outlets in handles.
• Easy relamping cage.
• Internal strain relief withstands 30 lb/9.1 kg. pull test.
• All-weather cords with molded plugs.
• Long-life Levolier™ switch mechanism in handle with protective
thumb guard.
Standard Materials
Lighting: McGill Temporary
• Cage: 10 gauge steel wire
• Cord: thermoplastic
• Handle: yellow, grease-resistant, high quality rubber
7000-SG-38
Certifications and Compliances
• CSA Certified (with cord): LL89639
• CSA Certified (without cord): LL56247
• CSA Standard: C22.2 No. 12
with out Cord
Handle and cage
7000-G-38
Catalog Number
with 25'/7.6m
16/3-SJTW Cord
with 50'/15.2m
16/3-SJTW Cord
7025-G-38
7050-G-38
Handle and cage
C7000-G-38 V
C7025-G-38 V
C7050-G-38 V
Handle and cage with switch
7000-SG-38
7025-SG-38
7050-SG-38
Handle and cage with switch
C7000-SG-38 V
C7025-SG-38 V
C7050-SG-38 V
Lighting
Accessories and Replacement Parts
With Out Reflector
Catalog Number
With Reflector
with Trap
1455-38
—
1455-38-T
Cages
Cage for 7000-38
Catalog Number
With Out Switch
With Switch
Handles and Sockets
Handle for 7000, 7001, 7002
Grounding clamp
6403
8959
6404-1
8950
25’/7.6m
16/3-SJTW
50’/15.2m
16/3-SJTW
6229-1
6229-2
Cord Sets
Cord set with molded plugs
V CSA Certification only.
1442
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
6000 Series Commercial-Duty Extension Lights
Polypropylene Handle with Receptacle
Features
• Commercial-duty extension lights resist impact, abrasion and oil.
• Three wire grounded handles with convenience receptacle.
• Easy-open, NO-ROL cage with rotating hook saves time and
permits precise lamp positioning.
• Plated metal parts resist rust and corrosion.
• All-weather cords have molded plugs.
• 10 Amp, 125 Vac receptacle rating.
• Cage accommodates 100 Watt max. bulbs.
• Push-through switch.
• Accommodates 16/3 cord type only.
Standard Materials
6025-SRG
• Cord: 16/3-SJTW yellow thermoplastic
• Cage: 10 gauge steel
Standard Finish
• Cage: zinc-plated
Certifications and Compliances ➊
UL Listed: E59071
UL Standard: 153
Meets OSHA requirements
CSA Certified: LL89639
Meets OSHA requirements
Catalog Numbers
with 1'/0.3m
16/3-SJTW Cord
with 25’/7.6 m
16/3-SJTW Cord
with 50’/15.2 m
16/3-SJTW Cord
Handle and cage with switch and reflector
6012-SRG ➋
6025-SRG
6050-SRG
Handle and cage with switch and reflector
C6012-SRG ➌ V
C6025-SRG V
C6050-SRG V
Handle and cage with switch and reflector and GFCI
—
6025-SRG-GFCI
Lighting: McGill Temporary
•
•
•
•
•
—
Lighting
➊ 100 Watt Maximum for UL Listing and CSA Certification.
➋ UL Listed for cord reel usage only.
➌ CSA Listed for cord reel usage only.
V CSA Certification only.
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
1443
5000 Series Industrial Extension Lights
Thermoplastic Handle With or Without Receptacle
Features
• Industrial-duty extension lights resist impact, abrasion and oil.
• Yellow handles with receptacle, yellow cords, and grounded
cages enhance safety, while easy-open cages speed relamping.
• All-weather cords have molded plugs for durability.
• Cages feature rotating hooks and NO-ROL design for accurate
light positioning.
• Accommodates up to 200 Watt rough service bulbs.
• Meets NEC requirements for power tool grounding.
• 13 Amp, 125 Vac receptacle rating.
• Long-life Levolier™ switch mechanism in handle with protective
thumb guard.
5000-SRG
5000-SRG, easy open cage
Standard Materials
• Cords: 16/3-SJTW thermoplastic
• Cages: 10 gauge steel
Standard Finish
• Cages: zinc plated, chrome finish
• 15 Amp, 120 Volt CSA Certified versions available. Items
available in a CSA version will be marked with a V. Add the
prefix C to the beginning of the catalog number.
5025-SRG
Certifications and Compliances ➊
•
•
•
•
•
•
•
UL Listed (with cord): E59071
UL Listed (without cord): E59054
UL Standard: 153
Meets OSHA requirements
CSA Certified (with cord): LL89639 V
CSA Certified (without cord): LL56247 V
CSA Standard: C22.2 No. 12
Lighting
Lighting: McGill Temporary
Options
➊ 100 Watt Maximum for UL Listing and CSA Certification.
V CSA Certification only.
1444
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
5000 Series Industrial Extension Lights
Thermoplastic Handle With or Without Receptacle
with out Cord
Closed-End Extension Lights
Handle and cage
Handle and cage
Handle and cage with reflector
Handle and cage with reflector
Handle and cage with switch
Handle and cage with switch
5000-G
C5000-G V
5000-RG
C5000-RG V
5000-SG
Catalog Numbers
with 1'/ 0.3m
with 25’/7.6m
16/3-SJTW Cord
16/3-SJTW Cord
—
—
—
—
—
—
Handle and cage with switch and reflector
C5000-SG V
5000-SRG
5012-SRG ➊
Handle and cage with switch and reflector
C5000-SRG V
5012-SRG ➊
Handle and cage with switch and reflector and GFCI
Handle and cage, no receptacle
Handle and cage, no receptacle
Handle and cage with reflector, no receptacle
Handle and cage with reflector, no receptacle
Handle and cage with switch, no receptacle
5000-GN
C5000-GN V
5000-RGN
C5000-RGN V
5000-SGN
Handle and cage with switch and reflector, no receptacle
C5000-SGN V
5000-SRGN
Handle and cage with switch and reflector, no receptacle
C5000-SRGN V
Handle and non-metallic cage
Handle and non-metallic cage
Handle and non-metallic cage with reflector
Handle and non-metallic cage with reflector
Handle and non-metallic cage with switch
Handle and non-metallic cage with switch
Handle and non-metallic cage with switch and reflector
5050-G
C5025-G V
5025-RG
C5050-G V
5050-RG
C5025-RG V
5025-SG
C5050-RG V
5050-SG
C5025-SG V
5025-SRG
C5050-SG V
5050-SRG
C5025-SRG V
5025-SRG-GFCI
5025-GN
C5050-SRG V
C5025-GN V
5025-RGN
C5050-GN V
5050-RGN
C5025-RGN V
5025-SGN
C5050-RGN V
5050-SGN
C5025-SGN V
5025-SRGN
C5050-SGN V
5050-SRGN
C5025-SRGN V
5999-GH
C5050-SRGN V
C5999-GH V
5999-RGH
C5999-RGH V
5999-SGH
C5999-SGH V
5999-SRGH
C5999-SRGH V
6229-1
—
5050-GN
—
—
—
—
—
—
—
—
6229-2
Catalog Number
With Out Reflector
With Reflector
Cages
Wire cage
Vinyl insulated metal cage (100 Watt A-21)
Non-metallic cage (100 Watt A-19)
8171
08171
—
8170
08170
8224
Catalog Number
With Out Switch
With Switch
Handles and Sockets
Handle and socket for 5000
Handle and socket for 5000-N
Socket for 5000 and 5000-N
0877
0877-N
00868
0865
0865-N
868
➊ 100 Watt Maximum for UL Listing and CSA Certification.
V CSA Certification only.
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
1445
Lighting
Handle and non-metallic cage with switch and reflector
Replacement Cord Sets
Cord set with molded plugs
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
5025-G
Lighting: McGill Temporary
Handle and cage with switch, no receptacle
—
with 50’/15.2m
16/3-SJTW Cord
Industrial Extension Lights
Features
• RE-HL5SRG and RE-HL7G
– All-weather cords with molded plugs
– Long-life Levolier™ switch mechanism in handle with
protective thumb guard
• RE-HLG-P and RE-VHL100N
– Easy to handle and service
– Capable of long, continuous operation in some of industry’s
most demanding environments
RE-HL55RG
Standard Materials
•
•
RE-HL5SRG and RE-HL7G
– Cage: 10 gauge steel wire
– Handle: yellow, grease-resistant, high quality rubber
RE-HLG-P and RE-VHL100N
– Handle and cage: nonmetallic composition
RE-HLG-P
Certifications and Compliances
Lighting: McGill Temporary
• UL Listed: E65418
• UL Standard:153
Description
Max. Lamp
Watts
Weight Ea.
Oz./Grams
Catalog
Number
100 W
15/425
RE-HL5SRG
100 W
20/567
RE-HL7G
75 W
8/227
RE-HLG-P *
100 W
19/539
RE-VHL100N *
Grounded handlamp with switch and receptacle
With yellow malamine phenolic handle and deluxe
wire metal guard. Use with maximum 16/3 SO or
SJOOW cord.
Grounded handlamp without switch or receptacle
Lighting
With yellow rubber handle and vinyl coated wire metal
guard. Meets OSHA requirements and NEC 511.4(B)
(2) for commercial garages, repair and storage
Grounded handlamp without switch or receptacle
With yellow polypropylene handle and guard.
Meets OSHA requirements and NEC 511.4(B)(2) for
commercial garages, repair and storage
Grounded NEMA 4X handlamp without switch or receptacle
Enclosed and gasketed handlamp with yellow
polyester handle and teflon globe. For indoor use
only. Meets OSHA requirements and NEC 511.4(B)(2)
for commercial garages, repair, and storage.
* NOT UL Listed.
1446
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
13 Watt
Handy Compact Fluorescent Work Light
Applications
• The compact light provides cool operation, allowing for work
in small areas without excessive heat build-up or burns from
accidental contact.
Features
• This energy-efficient work light features an exclusive 10,000
hour, 13 Watt rough service twin tube fluorescent lamp.
• Optional magnetic base with removable plastic swivel hook
available.
• 13 Watt, 120 Volt PLC, 0.59"/15 mm lamp.
• Double insulated, enclosed electrical components.
• Convenient on/off switch under domed cap.
• Durable construction for industrial and commercial applications.
Standard Materials
5331-0001
• Cord and molded plug: 18 gauge SJTOW oil-resistant
• Outer tube with reflector break-resistant polycarbonate
Certifications and Compliances
• UL Listed: E59071
• UL Standard: 153
Lighting: McGill Temporary
5331-0008
(Magnetic base and removable swivel hook assembly)
Catalog Number
120V, 13 Watt lamp, 2”/50.8 mm dia., 11-1/2”/292.1 mm length with 25’/7.6 m, 18/2-SJTOW yellow cord,
in-line ballast, and built-in switch
5331-0001
Replacement 13 Watt lamp for 5331-0001 (shock resistant, rough service)
5331-0002
Magnetic base and removable swivel hook assembly
5331-0008
Scratch Guard
5331-0035
Lighting
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
1447
13 Watt
Rough Service Fluorescent Lamp
Applications
• The compact light provides cool operation, protecting personnel
from accidental contact burns.
Features
• This 13 Watt energy-efficient work lamp provides light output
equivalent to a 75-100 Watt incandescent with lamp life rated at
10,000 hours.
• Optional tool tap and scratch guard are available.
• Reflector directs light to work surface away from eyes.
• Scratch guard protects light.
• On/off switch, located under handle is water and dust resistant.
• Compact ballast located in handle.
• Rubber bumpers and handle protect light on impact.
• Exclusive in-line tool tap (110 Volt) with outlet cover.
5331-0034
Standard Materials
• Cord and molded plug: 16 or 18 gauge SJTOW oil-resistant
• Adjustable hooks with cushion tips: spring steel
Certifications and Compliances
Lighting: McGill Temporary
• UL Listed: E59071
• UL Standard: 153
5331-0008
(Magnetic base and removable swivel hook assembly)
Catalog Number
Fluorescent Lamp
13 Watt Handi-Light with tool tap and scratch guard, 25’/7.6 m 16/3-SJTOW
5331-0031
13 Watt Handi-Light with scratch guard and 25’/7.6 m 18/2-SJTOW
5331-0032
13 Watt Handi-Light with Saf-T-Tie insert: cord locking mechanism, tool tap, scratch guard and
18”/457.2 mm 16/3-SJTOW
5331-0034
Lighting
Accessories and Replacement Parts
13 Watt Handi-Light head kit with switch, ballast and scratch guard
5331-0033
Scratch guard only
5331-0035
13 Watt Handi-Light head kit with switch and scratch guard; less ballast
5331-0036
13 Watt lamp only (shock resistant, rough service)
5331-0002
Magnetic base and removable swivel hook assembly
5331-0008
1448
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
Fluorescent Work Lights
12 Volt, 13 Watt
Applications
• For applications requiring low-voltage, bright, energy-efficient
lighting.
Features
• The light is powered by a printed circuit, solid state ballast
connected to the lamp base.
• Hook with protective plastic tip, allowing for the light to hang on
user’s belt or shoulder strap for hands-free operation.
• Models available with 20’/6.1 m 18/2-SJTOW oil-resistant, low
temperature cord or 1’/0.3 m to 5’/1.5 m neoprene black coil
cord; both with male lighter plugs on the ends.
• Ideal for use in confined areas.
• Replaceable 13 Watt, 12 Volt, 12.5 Amp Vac twin tube lamp.
• Ballast designed to operate at -4 °F/-20 ˚C.
• Ballast protected against voltage surges up to 18 Volts.
• Convenient on/off switch.
• Optional battery pack with charger available.
• Optional magnetic base with removable plastic swivel hook
available.
5331-0003
5331-0004
Standard Materials
Lighting: McGill Temporary
• Single metal hook with protective plastic tip
• Break-resistant polycarbonate outer tube with reflector
5331-0008
(Magnetic base and removable swivel hook assembly)
Lighting
Catalog Number
Work Lights
12 Volt, 13 Watt lamp, 2”/50.8 mm dia., 11-1/2”/292.1 mm length with 20’/6.1 m 18/2-SJTOW yellow cord
and male lighter plug
5331-0003
12 Volt, 13 Watt lamp, 2”/50.8 mm dia., 11-1/2”/292.1 mm length with 1’/0.3m-5’/1.5 m coil cord and male
lighter plug
5331-0004
Accessories and Replacement Parts
13 Watt lamp only (shock resistant, rough service)
5331-0002
Magnetic base and removable swivel hook assembly
5331-0008
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
1449
Battery Pack with Charger
Applications
• Ideal for use with 12 Volt, 13 Watt fluorescent work lights when
working in remote areas. Charger plugs into 120 Vac and
charges at 1.2 amps, 12 Vdc. Charger is furnished with 6’/1.8
m cord and male lighter plug to insert into the female outlet of
the battery. Charger then plugs directly into a 120 Volt outlet.
If battery is discharged to recommended maximum depth,
the charger requires 16 hours to fully recharge. As battery is
charged, the output of the charger reduces to low level. Battery
must be removed from the charger within three days. Fully
charged battery will operate a work light for about 5 hours
continuously
Features
Lighting
Lighting: McGill Temporary
•
•
•
•
7 Amp hour capacity, sealed lead acid type battery.
Taper charger.
Safety vent opens if battery is overheated.
Battery furnished with 1’/0.3 m power cord having female
12 Volt outlet.
• Battery pack:
5.75 lbs/2.6 kgs
6”/152.4 mm height
2-1/2”/63.5 mm width
3-1/2”/88.9 mm length
5331-0005
Standard Material
• Battery case: rugged nylon with double zipper, closed cell foam
padding on the sides and bottom
• 2”/50.8 mm adjustable web belt with quick release buckle
• Two “D” rings to connect the hooks of the shoulder strap
• Shoulder strap is 60”/1524.0 mm long with 1'/0.3 m long foam
pad, adjustable strap on each end.
• Triangular “D” ring provides a place to hang your light to give
hands-free lighting.
Catalog Number
Battery Pack
Battery pack, charger, shoulder strap, and case with belt
5331-0005
Accessories and Replacement Parts
13 Watt, 12 Volt, 1.25 Amp DC lamp (shock resistant, rough service)
5331-0006
7 Amp hour battery assembly
5331-0007
1450
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
Fluorescent Industrial Extension Lights
Applications
• Compact, lightweight with hinged hooks, these fluorescent
extension lights were designed to carry and use virtually
anywhere.
Features
•
•
•
•
•
•
•
Ideal for use in confined areas.
Emanates soft, glare-free light.
Safe and durable, these lamps remain cool to the touch.
Outer tube protects 15, 8, or 4 Watt lamps.
Durable, heavy-duty construction throughout.
Low energy, long-life.
No exposed metal parts.
Standard Materials
• Impact resistant plastic
5330-1525
5330-0818
Certifications and Compliances
UL Listed: E59071
UL Standard: 153
Meets OSHA requirements
CSA Certified: LL89639 V
CSA Standard: C22.2 No. 12 V
15 Watt Extension Lights
Catalog Number
with 25’/7.6m Cord
with 50’/15.2m Cord
15 Watt lamp 2 -1/8”/54.1 mm dia., 22-1/2”/571.5 mm length, with SJTO yellow cord — 18/3
from 3 prong plug to ballast, 18/2 to lamp. No. F15T8/CW bulb and FS-2 starter furnished
5330-1525
15 Watt lamp 2 -1/8”/54.1 mm dia., 22-1/2”/571.5 mm length, with SJTW yellow cord — 16/3
from 3 prong plug to ballast, 18/2 to lamp. No. F15T8/CW bulb and FS-2 starter furnished
5332-1525 V
—
with 15'/4.6m
18/2-SJTO Cord
with 22'/6.7m
18/2-SJTO Cord
4 Watt, F4T5/CW; 11”/279.4 mm overall length
5330-0411
5330-0418
8 Watt, F8T5/CW; 17”/431.8 mm overall length
5330-0811
5330-0818
8 Watt, F8T5/CW; 17”/431.8 mm overall length
5332-0825 V
5332-0818 V
5330-1550
Lighting: McGill Temporary
•
•
•
•
•
4 and 8 Watt Extension Lights
Catalog Number
Plastic shield for 5330-0411 and 5330-0418
5330-0400
Hook only for 5330-0411, -0418, -0811, and -0818
5330-0401
Plastic shield for 5330-0811 and 5330-0818
5330-0800
Plastic shield for 5330-1525
5330-1500
Hooks, plastic, set of two (2) for 5330-1525
5330-1501
V CSA Certification only..
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
1451
Lighting
Accessories and Replacement Parts
High Intensity Low-Voltage Extension Lights
Features
• Compact, durable, and safe 30 Watt spot and 35 Watt flood
lights.
• Ideal for use where low-voltage and maximum illumination are
needed.
• Powerpak transformer converts 120 Vac to 12 Vac, also
available as separate item.
• Spot and flood light available with battery clips where no voltage
conversion is necessary.
• Available with battery clips where no voltage conversion is
necessary.
• Heavy-duty cords, plugs, and connectors.
• TWIST-LOK connector permits economical cord and lamp
replacement.
5329-4000
Standard Materials
Lighting: McGill Temporary
• Bulb and powerpak transformer
• Secondary cord: 50’/15.2 m 16/2-SJTO
• Handle: impact-resistant plastic
• Lens: polycarbonate
Catalog Number
with Power Pack
Transformer
with Battery Clips
Complete unit with 30 W, 50,000 candle power spot bulb; 50’/15.2 m 16/2-SJTO cord and plug
5329-4000 ➊
5329-4001 ➊
Complete unit with 35 W, 325 candle power flood bulb; 50’/15.2 m 16/2-SJTO cord and plug
5329-4010 ➋
5329-4011 ➋
Lighting
Accessories and Replacement Parts
Catalog Number
Mini-Powerpak with 5’ 16/3-SOW primary cord
5329-0015
30 Watt spot light with 50’ 16/2-SJTO cord and TWIST-LOK connector
5329-4002 ➊
35 Watt flood light with 50’ 16/2-SJTO cord and TWIST-LOK connector
5329-4012 ➋
Plastic lens
5329-4003
Lens retaining ring
5329-4004
➊ Accommodates G.E. bulb #4405 and 4405-1.
➋ Accommodates G.E. bulb #4422.
1452
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
Mini-Powerpak Low-Voltage Extension Lights
Features
• Lightweight, compact transformer converts 120 Vac to 12 Vac
lighting.
• Under 6 lbs./2.7 kgs total weight.
• Transformer potted and sealed to resist moisture.
• Fuse protected primary fuse.
• TWIST-LOK connector.
• 75 W low-voltage bulb included.
Standard Material
• Extension light
• Transformer: 3” x 3-1/2” x 7”/76.2 x 88.9 x 177.8 mm
• Power cord: 5’/1.5 m 16/3-SOW
Certification and Compliance
5329-7010
• Meets OSHA requirements
7000-G extension light with 25’/7.6 m 16/3-SJTW Cord
5329-7000
7000-RG extension light with 25’/7.6 m 16/3-SJTW Cord
5329-7010
Lighting: McGill Temporary
Catalog Number
Extension Lights
Complete unit with power supply cord, Mini-Powerpak transformer
Accessories and Replacement Parts
Mini-Powerpak with 5’/1.5 m 16/3-SOW primary cord
5329-0015
25’/7.6 m 16/3-SJTW secondary cord assy., with TWIST-LOK plug
5329-0003
75 Watt low-voltage medium base A-21 bulb
6461
Lighting
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
1453
Fluorescent Hand Lamps
Explosionproof. 13 Watt Twin Tube and 26 Watt Quad
Class I, Division 1, Groups C, D
Class II, Division 1, Groups F, G
Features
• This portable, fluorescent light features durable, heavy-duty
construction with non-metallic guard, swivel hook and handle
assembly.
• The handle holds a 125 Volt rated ballast designed to operate
on 50 or 60 Hz with recyclable thermal protection.
• “T” Number: T6.
• Easy maintenance.
• Completely watertight.
• No exposed metal parts.
• 900 lumens for 13 Watt unit.
• 1800 lumens for 26 Watt unit.
• Corrosion-resistant.
• 4”/101.6 mm outside diameter.
• 23-1/2”/596.9 mm length.
• 3-1/2 lbs/1.6 kgs.
Standard Materials
• Globe: tempered glass
Lighting: McGill Temporary
Certifications and Compliances
5227-0006
• UL Listed: E43473
• UL Standard: 844
Catalog Number
13 Watt Twin Tube Selection Chart
Hand lamp with 50’/15.2 m 16/3-SO cord (male plug not included)
5227-0003
Twin tube hand lamp with out cord
5227-0006
26 Watt Quad Tube Selection Chart
5227-0007
Quad tube hand lamp with out cord
5227-0008
Lighting
Hand lamp with 50’/15.2m 16/3-SO cord (male plug not included)
1454
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
Tubular Fluorescent Inspection Light
Explosionproof. 8 Watt
Class I, Division 1, Group D
Class II, Group G
Applications
• This inspection light is ideal for inspection of aircraft fuel
systems because of its narrow diameter, light weight and cool
operating temperature.
Features
• Furnished with high impact aluminum alloy guard and nonsparking swivel hook.
• “T” Number: T5.
• Easy maintenance — only glass globe requires factory
replacement.
• 450 lumens.
• 2.5”/63.5 mm outside diameter.
• 27”/685.8 mm length.
• 3 lbs., 3 oz./1.5 kgs.
Certifications and Compliances
5227-0004
• UL Listed: E43473
• UL Standard: 844
5227-0004
Lighting: McGill Temporary
Catalog Number
Hand lamp with 50’/15.2 m 16/3-SO cord (male plug not included)
Lighting
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
1455
Industrial Extension Lights
Explosionproof
Class I, Division 1, Groups C, D
Features
• This watertight portable extension light features a lightweight
aluminum alloy guard with a non-sparking swivel hook, as well
as a chemical-resistant handle and globe holder.
• High impact glass globe accepts an A-21.
• The one-piece construction of the 15 Amp, 240 Vac socket
withstands temperatures up to 360 ˚F/182 °C in service.
• “T” Number: T3A.
• Completely watertight.
• Accommodates 16/3-SO or 14/3-SO cord.
• 5”/127 mm outside diameter.
• 18-1/2”/469.9 mm length.
• 4 lbs/1.8 kgs.
Standard Materials
• 100 Watt rough service bulb
5227-0005
Certifications and Compliances
Catalog Number
Extension Lights
Hand lamp with 50’/15.2 m 16/3-SO cord (male plug not included)
5227-0001
Hand lamp with out cord
5227-0005
Accessories and Replacement Parts
Handle assembly and lamp holder
5227-9915
Guard and globe assembly
5227-9916
Lighting
Lighting: McGill Temporary
• UL Listed: E43473
• UL Standard: 844
1456
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
Low-Voltage, High Intensity Hand Lamp
Explosionproof
Class I, Division 1, Groups C, D
Applications
• Ideal for inspecting refinery towers, manholes, or railroad tank
cars.
Features
• This low-voltage spotlight uses a 12 Volt, PAR-36, 30 Watt,
automotive type, sealed beam high intensity lamp.
• The aluminum light guard is high impact alloy and swivel hook is
non-sparking.
• “T” Number: T3C.
• 30,000 beam candlepower.
• 1/4”/6.4 mm thick glass lens.
• Can be powered by low-voltage transformer or alternate 12 Volt
source.
• 5-1/2”/139.7 mm outside diameter.
• 16”/406.4 mm length including hook.
• 3 lbs/1.4 kgs.
5227-0002
Standard Materials
• Light guard: aluminum
Certifications and Compliances
Catalog Number
Hand lamp with 50’/15.2 m 16/3-SO cord (male plug not included)
5227-0002
Lighting: McGill Temporary
• UL Listed: E43473
• UL Standard: 844
Lighting
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
1457
Incandescent Utility Lights
Applications
• Ideal for food processing plants, barns, garages, warehouses,
and workshops.
• Low cost, corrosion-resistant, enclosed utility lights, complete
with base, wiring box, and globe, are convenient to use.
Features
• Fasten directly to walls, ceilings, or structural members — no
separate outlet box required.
• Glass or plastic globes screw out for easy replacement of A-21
bulbs (not included) up to 150 Watts.
• High quality materials and sockets assure long, trouble-free
service life.
• 3-1/2”/88.9 mm diameter; 9-1/2”/241.3 mm height
• Two 5/16”/7.9 mm diameter mounting holes on 4-3/8”/111.3
mm centers.
• Moisture-resistant construction with no exposed metal parts.
• Large compartment for easy wiring.
• Super strong, impact-resistant, thermoplastic mounting unit.
• For use up to 100 ˚F/38 °C ambient temperature.
• Accommodates up to 150 Watts max. domestic A-21 bulbs.
• For use with either 1/2”/12.7 mm or 3/4”/19.1 mm rigid
non-metallic conduit.
606 with 1435-6
653
Certifications and Compliances
UL Listed: E8646
UL Standard: 1598
CSA Certified: LL56247 V
CSA Listed: C22.2 No. 250.0 V
Lighting
Lighting: McGill General
•
•
•
•
V CSA Certification only.
1458
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
Incandescent Utility Lights
Catalog Numbers
Wiring Compartment
Cubic Inch/Cubic
Decimeter
Supply Wire
Rating
°F/°C
For damp locations
15/0.25
257/125
600
601
For damp locations
15/0.25
221/105
C600 V
C601 V
For damp locations
12/0.20
140/60
603
604
For damp locations
12/0.20
140/60
C603 V
C604 V
Sealed unit for wet locations
12/0.20
140/60
605
606
Sealed unit for wet locations
12/0.20
140/60
C605 V
C606 V
For damp locations
15/0.25
257/125
640
641
For damp locations
15/0.25
221/105
C640 V
C641 V
For damp locations
12/0.20
140/60
643
644
For damp locations
12/0.20
140/60
C643 V
C644 V
For damp locations
15/0.25
257/125
650
651
For damp locations
15/0.25
221/105
C650 V
C651 V
For damp locations
12/0.20
140/60
653
654
For damp locations
12/0.20
140/60
C653 V
C654 V
1/2"/12.7 mm
Threaded Conduit Opening
3/4"/19.1 mm
Threaded Conduit Opening
Utility light with glass globe
Utility light with clear plastic globe ➊
Utility light with red plastic globe ➊
Accessories and Replacement Parts — Additional plastic globes see Protect-O-Globes
Lighting: McGill General
Catalog Number
1435-6
Base and socket only for 600, 640, and 650
610
Base and socket only for 601, 641, and 651
611
Base and socket only for 603, 643 and 653
5213-0623
Base and socket only for 604, 644 and 654
5213-0672
Base, socket, and seal assembly only for 605
5213-0637
Base, socket, and seal assembly only for 606
5213-0638
Socket only for 15 cubic inch/ 0.25 cubic decimeter wiring compartment
600-3
Socket only for 12 cubic inch/0.20 cubic decimeter wiring compartment
606-3
Glass globe only for 600, 601, 603, and 604 - 6-11/16"/296.9 mm long
0753
Glass globe only for 605 and 606 - 6-11/16"/296.9 mm long
0753-HR ➋
Clear plastic globe only for 640, 641, 643 and 644 - 6-1/8"/6.1 mm long
649
Red plastic globe only for 650, 651, 653 and 654 - 6-1/8"/6.1 mm long
659
Green plastic globe only - 6-1/8"/6.1 mm long
669
Lighting
Protective metal cage for glass globes only
➊ Plastic globes max. 75 Watt base-up mounting.
➋ Heat resistant globes required for wet locations.
V CSA Certification only.
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
1459
Fluorescent Utility Lights
Applications
• Whether the application calls for securely lighting a livestock
operation, damp barn, or even a harsh, outdoor environment,
the 22 Watt fluorescent utility light delivers energy-efficient,
trouble-free service for a variety of demanding lighting needs.
The single unit incorporates non-corrosive construction, its
own wiring compartment, and an impact-resistant thermoplastic
mounting base.
Features
Lighting
Lighting: McGill General
• Removable globe for effortless “push-pull” relamping and
cleaning.
• Standard 0.59"/15 mm, 22 Watt quad-tube lamp provides 75%
greater energy efficiency.
• Average service life of 10,000 hours.
• Fastens directly to walls, ceilings, or structural members.
• 3-1/2”/88.9 mm diameter, 9-1/2”/241.3 mm height.
• Two 5/16”/7.9 mm diameter mounting holes on 4-3/8”/111.3
mm centers.
• 22 Watt, 120 Volt PLC, 0.59"/15 mm lamp equivalent to 75 Watt
incandescent.
• Delivered complete with globe, ballast, lamp, socket and wiring
box.
• For use up to 100 ˚F/38 °C ambient temperature.
• Use with either 1/2”/12.7 mm or 3/4”/19.1 mm rigid non-metallic
conduit.
600-FL22
Options
• CSA Certified versions available. Items available in a CSA
version will be marked with a V. Add the prefix C to the
beginning of the catalog number.
Certifications and Compliances
•
•
•
•
UL Listed: E13761
UL Standard: 1598
CSA Certified: LL56247
CSA Listed: C22.2 No. 250.0
Wiring Compartment
Cubic Inch/Cubic
Decimeter
Supply Wire
Rating
°F/°C
Utility light with glass globe
For damp locations
For damp locations
Sealed unit for wet locations
Sealed unit for wet locations
Utility light with clear plastic prismatic globe
For damp locations
For damp locations
12/0.20
12/0.20
12/0.20
12/0.20
194/90
221/105
194/90
221/105
12/0.20
12/0.20
194/90
221/105
Sealed unit for wet locations ➊
12/0.20
Sealed unit for wet locations ➊
Utility light with red plastic prismatic globe
For damp locations
For damp locations
Sealed unit for wet locations ➊
Catalog Numbers
1/2"/12.7 mm
3/4"/19.1 mm
Threaded Conduit Opening Threaded Conduit Opening
600-FL22
601-FL22
C600-FL22 V
605-FL22
C601-FL22 V
606-FL22
C605-FL22 V
C606-FL22 V
640-FL22
641-FL22
194/90
C640-FL22 V
645-FL22
C641-FL22 V
646-FL22
12/0.20
221/105
C645-FL22 V
C646-FL22 V
12/0.20
12/0.20
194/90
221/105
12/0.20
194/90
650-FL22
651-FL22
C650-FL22 V
655-FL22
C651-FL22 V
656-FL22
12/0.20
221/105
Sealed unit for wet locations ➊
C655-FL22 V
Accessories and Replacement Parts — Additional plastic globes see Protect-O-Globes
C656-FL22 V
Glass globe only - 6-11/16”/220.7 mm long
Clear plastic prismatic globe only - 8-1/4”/209.6 mm long
Red plastic prismatic globe only - 8-1/4”/209.6 mm long
Protective metal cage for glass globes only
22 Watt, 120 Volt PLC,0.59" /15 mm lamp
Base, socket, and ballast assembly only for 600-FL22
Base, socket, ballast, and seal assembly only for 605-FL22
Catalog Number
0753
5213-6649
5213-6659
1435-6
5213-6660
5213-6623
5213-6625
➊ For base-up operation only.
V CSA Certification only..
1460
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
Protect-O-Sleeves
For Fluorescent Tubes
Applications
• Reusable Protect-O-Sleeves encase existing fluorescent tubes
to insulate and improve lighting efficiency at low temperatures.
• High tensile, polycarbonate strength protects people,
equipment, and products.
• Available for applications requiring ultra-violet light filtering
such as museums, department stores, and art galleries, where
fluorescent lighting can deteriorate materials.
2260 (T-12)
Features
• Furnished with end caps that fit snugly between lamp and
sleeve.
• Filter Ray sleeves are designed to filter out UV rays in the range
of 0-385 nanometers when used with 400 M.A. lamps.
• Insulates lamps up to 2.5 times at 20 ˚F/-6 °C.
• Accommodates lamps up to 800 milliamps ➊.
• For use up to 100 ˚F/38 °C ambient temperature.
• Most T-8 and T-12 versions available in colors.
Certifications and Compliances
2270 (T-8)
2546 (T-5)
• Meets OSHA safety requirements
T-5 Clear Protect-O-Sleeves ➋
Lamp Type
Nominal Lamp Length
Inches/Millimeters
Catalog Number for Sleeve with 2 Caps
for T-5 Diameter Lamps
Box
Quantity
F-14
22/558.8
2522
48
F-21
34/863.6
2534
24
F-28
46/1168.4
2546
24
T-8 and T-12 Clear Protect-O-Sleeves ➊
Nominal Lamp Length
Inches/Millimeters
Catalog Number for Sleeve with 2 Caps
for T-12 Diameter Lamps
Catalog Number for Sleeve with 2 Caps
for T-8 Diameter Lamps
Box
Quantity
F-15
18/457.2
—
2270
24
F-20
24/609.6
2268
2278
24
F-30
36/914.4
—
2271
24
F-32
48/1219.2
—
2295
24
F-36
36/914.4
2269
—
24
F-40
48/1219.2
2260
—
24
F-40
60/1524.0
—
2286
24
F-48
46/1168.4
2261
—
24
F-60
60/1524.0
2276
—
24
F-72
72/1828.8
2262
2272
24
F-96
96/2438.4
2263
2273
24
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
1461
Lighting
➊ No. 2285 heat sink screens must be used with T-8 and T-12 800-milliamp maximum HO lamp bases. Two heat sink screens required per sleeve (one at each
end between lamp and sleeve). HO lamps create excessive heat at the ends. The open metal mesh of the heat sink screens spreads the excess heat over a
larger area to help eliminate deterioration of the sleeve. NOT for use with VHO lamps.
➋ NOT for use with HO or VHO lamps.
Lighting: McGill Lamp Protection
Lamp Type
Protect-O-Sleeves
For Fluorescent Tubes
Clear UV Filtering Protect-O-Sleeves ➌
Lamp Type
Nominal
Lamp Length
Inches/Millimeters
Catalog Number for Sleeve with 2 Caps
for T-12 Diameter Lamps
for T-8 Diameter Lamps
Box
Quantity
F-32
48/1219.2
—
2295-FR
24
F-40
48/1219.2
2260-FR
—
24
F-96
96/2438.4
2263-FR
2273-FR
24
Colored Protect-O-Sleeves ➊
Catalog Numbers for Sleeve with 2 Caps
Lamp Type
Blue
Green
Pink
Red
Yellow
Box
Quantity
F-32, T-8
2295-B
2295-G
2295-P
2295-R
2295-Y
12
F-40, T-12
2260-B
2260-G
2260-P
2260-R
2260-Y
12
F-48, T-12
2261-B
2261-G
2261-P
2261-R
2261-Y
12
F-72, T-12
2262-B
2262-G
2262-P
2262-R
2262-Y
12
F-96, T-8
2273-B
2273-G
2273-P
2273-R
2273-Y
12
F-96, T-12
2263-B
2263-G
2263-P
2263-R
2263-Y
12
Accessories and Replacement Parts
Lighting
Lighting: McGill Lamp Protection
Catalog Number
Universal end cap for T-5, 2500 series
2508
Universal end cap for T-12, 2260 series
2265
Heat sink screen for HO lamp bases
2285 ➊
Universal end cap for T-8, 2270 and 2295 series sleeves produced prior to 8-1-97
2274
Universal end cap for T-8, 2270 and 2295 series sleeves produced after 8-1-97
2279
Universal T-8 filter ray end cap for 2273-FR and 2295-FR
6840
Universal T-12 filter ray end cap for 2260-FR and 2263-FR
6846
➊ No. 2285 heat sink screens must be used with T-8 and T-12 800-milliamp maximum HO lamp bases. Two heat sink screens required per sleeve (one at each
end between lamp and sleeve). HO lamps create excessive heat at the ends. The open metal mesh of the heat sink screens spreads the excess heat over a
larger area to help eliminate deterioration of the sleeve. NOT for use with VHO lamps.
➌ Sleeves filter out ultraviolet light in the range of 0 to 385 nanometers when used with 400 M.A. lamps. NOT for use with HO or VHO Lamps.
1462
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
Protect-O-Tubes
For Fluorescent Tubes
Applications
• Protect-O-Tubes offer convenient and environmentally safe
lighting for food, drug, and related industries.
Features
• Complete fluorescent lighting unit
• Adhesively attached end caps provide added safety for glass
containment.
• Air space between the lamp and sleeve acts as a cushion and
helps to protect the tube from breakage and diffuses heat.
• Improves light transmission and provides longer lamp life.
• For use up to 100 ˚F/38 °C ambient temperature.
• Available in T-8 or T-12 versions.
Standard Finish
• Lighting unit: polycarbonate sleeve, lamp, and end caps
• End caps: polypropylene
Certifications and Compliances
• Approved for use by the USDA and satisfying the requirements
of OSHA and FDA
• Meets safety requirements
Lamp Base
Med. Bi-pin
Nominal Lamp Length
Inches/Millimeters
18/457.2
Catalog Number
of Sleeve, Lamp, and End Caps
4230
Box
Quantity
24
F-32/T-8/SP35
Med. Bi-pin
48/1219.2
4231
24
F-32/T-8/SPX35
Med. Bi-pin
48/1219.2
4232
24
F-32/T-8/SP41
Med. Bi-pin
48/ 1219.2
4233
24
F-32/T-8/SPX41
Med. Bi-pin
48/ 1219.2
4234
24
F-40/T-12/CW/RS/WM
Med. Bi-pin
48/ 1219.2
4261
24
F-40/T-12/LW/RS/WM
Med. Bi-pin
48/ 1219.2
4262
24
F-40/T-12/SPX35
Med. Bi-pin
48/ 1219.2
4265
24
F-40/T-12/D
Med. Bi-pin
48/ 1219.2
4266
24
F-40/T-12/WW
Med. Bi-pin
48/ 1219.2
4269
24
F-48/T-12/LW/WM
Single-pin
48/ 1219.2
4263
24
F-48/T-12/CW/HO
Recessed Double Contact
48/ 1219.2
4264 ➊
24
F-72/T-12/SPX35
Single-pin
72/1828.8
MCG4250
12
Single-pin
96/2438.4
4281
12
Recessed Double Contact
96/ 2438.4
4283 ➊
12
F-96/T-12/CW/WM
Single-pin
96/ 2438.4
4284
12
F-96/T-12/D/WM
Single-pin
96/ 2438.4
4285
12
F-96/T-12/WW
Single-pin
96/ 2438.4
4286
12
Recessed Double Contact
96/ 2438.4
4287 ➊
12
F-96/T-12/D
F-96/T-12/CW/HO/WM
F-96/T-12/LW/HO/WM
Single-pin
96/ 2438.4
4288
12
F-96/T-12/SP65/HO
Recessed Double Contact
96/ 2438.4
4289 ➊
12
F-96/T-12/SP41/HO
Recessed Double Contact
96/ 2438.4
4290 ➊
12
F-96/T-12/LW/WM
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
Lighting
Note: Availability of lamp types shown above may be affected by the implementation of the Energy Policy Act of 1992.
➊ Two heat sink screens are furnished with all HO lamp styles to help eliminate excessive heat at the ends of the lamps.
Lighting: McGill Lamp Protection
Lamp Type
F-15/T-8/SPX35
1463
Tubeloc Holders
Applications
• Securely position and hold tubes in fluorescent fixtures
Features
• Shock resistant
• Styles to fit most fluorescent lamps in use today
Standard Finish
• Holders: shock resistant nylon
Certifications and Compliances
•
•
•
•
UL Listed: E59240
UL Standard: 1598
CSA Certified: LL36636
CSA Standard: C22.2
M180
Description
Catalog Number
M175
T-12 Recessed double contact; Slimline single-pin; medium bi-pin; T-17 power
groove with recessed double contact base (3/4”/19.1 mm dia. plunger)
M176
T-17 Bi-pin mogul base
M180
Lighting
Lighting: McGill Lamp Protection
T-8 and T-12 Bi-pin, 14-40 Watts
1464
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
Protect-O-Globes
For Incandescent Bulbs
Applications
• Protect lamps and the working environment with economical
polycarbonate globes that are virtually unbreakable.
• Ideal for the replacement of glass and wire guard combinations
where incandescent or HID lamps are used in vandal-proof
applications.
Features
• Various styles, sizes, and colors available.
• Prismatic globes provide lateral light diffusion.
• Smooth globes reduce operating temperatures, amplify light
source.
• Accommodates up to 150 Watts maximum, base-up operation.
1500-C
0604AP
3316
Certifications and Compliances
• Meets OSHA requirements
Description
Color
Thread Diameter
In/mm
Globe Dimensions
Inches/Millimeters — W x L
Maximum
Wattage
Catalog
Number
3—1/4/82.6
3—1/4/82.6
4—1/4/108.0
3—1/4/82.6
3—1/4/82.6
3—1/4/82.6
3—1/4/82.6
3—1/4/82.6
3—3/16/81.0
3—1/4/82.6
3—1/4/82.6
3—1/4/82.6
3—1/4/82.6
3—3/16/81.0
3—1/4/82.6
3—1/4/82.6
3—1/4/82.6
3—1/2 x 8—1/4/88.9 x 209.6
3—1/2 x 8—1/4/88.9 x 209.6
4—3/4 x 8—5/16/120.7 x 211.1
3—3/4 x 6—1/4/95.3 x 158.8
3—3/4 x 6—1/4/95.3 x 158.8
3—3/4 x 6—1/4/95.3 x 158.8
3—3/4 x 6—1/4/95.3 x 158.8
3—1/2 x 6—1/4/95.3 x 158.8
3—23/32 x 6/94.5 x 152.4
3—1/2 x 6—1/4/88.9 x 158.8
3—1/2 x 6—1/4/88.9 x 158.8
3—1/2 x 6—1/4/88.9 x 158.8
3—1/2 x 6—1/4/88.9 x 158.8
3—23/32 x 6/94.5 x 152.4
3—1/2 x 6—1/4/88.9 x 158.8
3—1/2 x 6—1/4/88.9 x 158.8
3—1/2 x 6—1/4/88.9 x158.8
60
60
150
60
60
60
60
60
75
60
60
60
60
75
60
60
60
0134CP ➊
0134CS ➊
1500-C
0604GP ➊
0604RP ➊
0604AP ➊
3—3/16/81.0
4—1/4”/108.0
3—7/16 x 1—5/8/87.4 x 41.4
3—7/16 x 1—5/8/87.4 x 41.4
75
150
3316
4014
Finish
0603CS ➊
0603GS ➊
0603RS ➊
0603AS ➊
0604CS ➊
0752-C
0604GS ➊
0604RS ➊
0604AS ➊
0604CP ➊
0752-P
Dimensions
A - 3-1/2”/88.9 mm
B - 7-1/2”/190.5 mm
C - 3.0”/76.2 mm
D - 3-1/4”/82.6 mm
E - 3-3/4”/95.3 mm
F - 1/2”/12.7 mm
Cylinder Prismatic
A - 3-1/2”/88.9 mm
B - 5-1/2”/139.7 mm
C - 3.0”/76.2 mm
D - 3-1/4”/82.6 mm
E - 3-3/4”/95.3 mm
F - 1/2”/12.7 mm
Cylinder Smooth
A - 3-3/4”/95.3 mm
B - 5-1/2”/139.7 mm
C - 3.0”/76.2 mm
D - 3-1/4”/82.6 mm
E - 1/2”/12.7 mm
Bullet Smooth
Lighting
➊ Can be used with McGill Incandescent and Fluorescent Utility Lights.
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
Lighting: McGill Lamp Protection
Globes
8—1/4”/209.6 mm cylinder
Clear
Prismatic
8—1/4”/209.6 mm cylinder
Clear
Smooth
8—5/16”/211.1 mm cylinder
Clear
Smooth
6—1/4”/158.8 mm bullet
Clear
Smooth
6—1/4”/158.8 mm bullet
Green
Smooth
6—1/4”/158.8 mm bullet
Red
Smooth
6—1/4”/158.8 mm bullet
Amber
Smooth
6—1/4”/158.8 mm cylinder
Clear
Smooth
6—1/4”/158.8 mm cylinder
Clear
Smooth
6—1/4”/158.8 mm cylinder
Green
Smooth
6—1/4”/158.8 mm cylinder
Red
Smooth
6—1/4”/158.8 mm cylinder
Amber
Smooth
6—1/4”/158.8 mm cylinder
Clear
Prismatic
6—1/4”/158.8 mm cylinder
Clear
Prismatic
6—1/4”/158.8 mm cylinder
Green
Prismatic
6—1/4”/158.8 mm cylinder
Red
Prismatic
6—1/4”/158.8 mm cylinder
Amber
Prismatic
Bases
Yellow plastic base for use with 0752-C/P globes
Yellow plastic base for use with 1500-C globe
1465
Wire Lamp Guards and Wire Lamp Guard Grounding Kit
Wire Lamp Guards
Wire Lamp Guard Grounding Kit
Applications
Application
• Wire lamp guards with universal collars help prevent breakage
and theft.
Features
• A wide variety of types and sizes is available to fit your diverse
needs.
• Heavy-duty, 10 or 12 gauge, zinc-plated construction ensures
long life.
• Easy to install.
• Vinyl coated versions available.
• Rust-resistant zinc plating with chromate finish.
• Clamp type guards for vapor-tight fixtures available.
• Spot welded steel wire ensures long life.
• To ensure that your lamps are grounded, and comply with
NEC and OSHA requirements, the grounding kit supplies a
metal fastener and 1'/0.3 m wire to connect wire lamp guards
to a grounding circuit.
Certifications and Compliances
• Meets OSHA requirements
• Meets NEC requirements
Certifications and Compliances
• Meets OSHA requirements
Wire Lamp Guards
Description
1.50/38.1
2100-2100-A
2200-2200-A
Vinyl coated GRIPON guards with out reflectors
1.50/38.1
V-2100BULK
V-2200BULK
PROTECTOR “O” guards; open bottom heavy-duty
1.50/38.1
1433
1434
Vinyl coated PROTECTOR “O” guards
1.50/38.1
V-1433
V-1434
—
2932
2933
Closed bottom wall and receptacle lamp guards
3.50/88.9
1438
—
Cage for utility light ➊
3.50/88.9
1435-6
—
1.69/0.51 — 2.63/0.8
1438-1
—
3.75/1.14 (1435-1)
1435-1
Guards for PAR and R-38 lamps
Guards for vapor-tight fixtures
1435-3 ➋
Wire Lamp Guard Grounding Kit
Description
Catalog Number
9995
Grounding Kit
Lighting
Catalog Number
for 100 W Bulb
for 200 W Bulb
GRIPON guards with out reflectors
Trap only to close bottom of 1433 and 1434
Lighting: McGill Lamp Protection
Collar Diameter
Inches/Millimeters
➊ See McGill Incandescent and Fluorescent Utility Lights.Plastic cages available, see McGill String-O-Lights.
➋ 300 Watt type PS25 lamp only.
1466
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
Fluorescent Lamp Changers
Grips Lamp
Lighting
Lighting: McGill Lamp Changers
Applications
• Eliminate the need for climbing ladders and scaffolds.
Features
• Changers securely grip lamps for easy removal.
• Two models to choose from.
• Models for spring-loaded, bi-pin, single-pin, or recessed double
contact lamps.
174
184
Catalog Number
Lamp Changers
Complete changer unit for up to 1—1/2”/38.1 mm diameter, 4’/1.2 m lamps that require 90˚ rotation or axial movement.
Includes changer head, four zinc-plated steel pole sections each 24”/609.6 mm long, and starter changer.
For T-8, T-10, T-12 single-pin, T-8, T-12 med. bi-pin, and T-10, T-12 recessed double contact lamps.
174
Complete changer unit for 1—1/2"/38.1 mm diameter, spring-loaded lamps up to 8'/2.4 m long.
Includes changer head and two-section aluminum telescoping pole extending to 12—1/2’/3.8 m.
184
Accessories and Replacement Parts
170-P
Zinc-plated 2'/0.6 m steel pole section for 174
Zinc-plated steel changer head only for 174
171-C
Aluminum starter changer only for 174
173-S
Fluorescent changer pull cord only for 174
01540
Yellow driver, five clips, and speed nuts for 184
5274-1743
Changing Lamps is Easy With McGill Fluorescent Lamp Changers
1. First, angle changer to wedge yellow driver between lamp and socket. Then snap changer onto tube by rocking changer gently.
2. Next, standing at end of changer, push pole so driver will extract fluorescent lamp out of socket.
Model #184
Snap on Tube
Wedge In
Wedge driver between
lamp and socket.
Snap changer onto tube.
Rock changer onto lamp.
Push against
Spring and extract
Push against changer
spring and extract.
Lamp Identification
The changers featured on this page accommodate the fluorescent lamps at right.
Single-pin: T-8, T-10, T-12
Medium bi-pin: T-8, T-12
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
Recessed double contact: T-10, T-12
1467
Incandescent Lamp Changers
Lighting: McGill Lamp Changers
Lighting
Rubber Covered Fingers with Garter Springs
Features
• Rubber covered fingers with garter springs make changing a
variety of lamp types simple.
• Hard-to-reach lamps are easily replaced without using ladders
or platforms.
• A variety of styles and sizes is available to fit practically all
commonly used lamps.
• Models for use with incandescent, mercury, metal halide, and
sodium lamps.
• Garter spring grips lamps firmly.
• Lightweight for ease-of-use and convenience.
• Insulated to help protect against shock.
• Changes lamps up to 25’/7.6 m height (poles sold separately).
151-CA
153-C
161-C
Lamp Size ➊
Wattage
Catalog Number
Changer head with angle adjustment ➋
A-15, -17, -19; G-16-1/2,-18-1/2
15-100
150-CA
Changer head with angle adjustment ➋
A-19, -21, -23; P-25; PS-25, -30, -35;
FLE-20/T-19 ➌; SL-18 ➌; G-25, -30
25-500 (18 fluorescent ➌)
151-CA
Changer head only
PS-35, -40; G-40, -48
25-500
152-C
Changer head only
PS-52; G-48, -64
750-1500 (incandescent)
153-C
Changer head only
T-16, -18, -20
1000-1500 (incandescent)
400-1000 (mercury)
154-C
Changer head only
R-52, -57
500-1000 (incandescent flood)
400-750 (mercury)
155-C
Changer head only
R-30, -40; PAR-30, -36, -38; ER-30, -40
50-500 (incandescent)
100-175 (mercury)
156-C
Changer head only
E-37; BT-37, -46; ED-37
400-700 (mercury)
400-1000 (metal halide)
158-C
Changer head only
R-60
750 (incandescent)
400 (mercury flood)
159-C
Changer head only
E-21, -23, -23-1/2, -25, -28;
ED-23-1/2, -28; BT-28
75-250 (mercury)
175-400 (metal halide)
50-1000 (sodium)
161-C
Changer head only
E-17, -18; ED-17, -18; B-17
50 (mercury)
35-400 (sodium)
70-175 (metal halide)
163-C
Lamp Identification
A lamp designation consists of a letter indicating the shape and a figure to identify the approximate diameter in eighths of an inch.
Lamps are measured through their greatest diameter. G-25 lamps are globe shaped with a 3-1/8”/79.5 mm diameter.
SL18
P
G
A
T
PS
E/ED
BT
PAR
R
ER
➊ Lamp size, not Wattage, determines proper changer. May not accommodate weight of greater Wattage lamps.
➋ Jointed angle adapter for easy removal of horizontally or angle mounted lamps included. Use with small headed units only.
➌ Not for use with angle adapter.
1468
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
Incandescent Lamp Changers
Rubber Suction Cups
Lighting
Lighting: McGill Lamp Changers
Features
• Rubber suction cups make it easy to change lamps where
space surrounding bulbs is limited.
• Made of durable synthetic rubber, these changers securely
fasten onto lamps and allow for safely changing lamps up to
25’/7.6 m heights (poles sold separately).
• For lamps with smooth face only.
157-C
162-C
166-C
Lamp Size *
Wattage
Catalog Number
Changer with rubber suction cups
R-40, -52, RB-52
75-1000 (incandescent spot/flood)
100-400 (mercury)
157-C
Changer with rubber suction cup
PAR-30, -36, -38
25-150 (incandescent)
75-100 (mercury)
162-C
Changer with rubber suction cup
R-20, -30, ER-30, PAR-20
30-75 (incandescent)
166-C
* Bulb size, not Wattage, determines changer to be used. Use on smooth surface lamps only.
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
1469
Lighting: McGill Lamp Changers
Lighting
Lamp Changer Accessories and Replacement Parts
Application
• Lightweight accessories and replacement parts provide a safe
and sure way to remove and replace bulbs.
Features
• For use with incandescent lamp changers, these 5’/1.5 m
insulated, interchangeable pole sections are designed for quick
assembly to desired length. Up to four poles can be securely
locked together with spring-loaded buttons.
• Broken lamp base remover has plastic shield designed to catch
fragments and help protect user. Fits 160-P lamp changer pole,
providing a fully insulated, safe, and sure way to remove bases
of broken lamps.
200
9260
160-P
Catalog Number
Interchangeable, wood insulated steel pole, 5’/1.5 m sections
160-P
Broken lamp base remover for standard and mogul lamp bases
200
Garter springs for 150-CA, 151-CA, 154-C, 161-C changer heads
7013
Garter springs for 152-C, 153-C, 156-C, 158-C changer heads
7014
Garter springs for 155-C and 159-C changer heads
7019
Spring clip and button for lamp changer poles
9260
1470
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
Notes
Lighting
Lighting: Notes
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
1471
Lighting: Notes
Lighting
Notes
1472
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.6 Linearized : No Encryption : Standard V4.4 (128-bit) User Access : Print, Extract Create Date : 2010:09:03 12:28:36-05:00 Creator : Adobe InDesign CS4 (6.0) Modify Date : 2010:09:07 08:36:29-05:00 Trapped : False XMP Toolkit : Adobe XMP Core 4.2.1-c043 52.372728, 2009/01/18-15:08:04 Metadata Date : 2010:09:07 08:36:29-05:00 Creator Tool : Adobe InDesign CS4 (6.0) Format : application/pdf Document ID : uuid:ee944a2f-6c96-4784-a8aa-a8401138a35b Instance ID : uuid:01d7ee61-f656-43d5-a9d1-8209dc4af869 Producer : Adobe PDF Library 9.0 Page Layout : SinglePage Page Mode : UseOutlines Page Count : 562EXIF Metadata provided by EXIF.tools