100841 Catalog

2014-07-05

: Pdf 100841-Catalog 100841-Catalog 781381 Batch5 unilog

Open the PDF directly: View PDF PDF.
Page Count: 562

Download100841-Catalog
Open PDF In BrowserView PDF
LIGHTING
Corrosive elements. Combustible dusts.
Flammable gases and vapors. For proper
illumination in extreme conditions, you
need a company that pushes safety to
the extreme. Appleton has expanded
the boundaries of technology, efficiency
and performance to ensure your lighting
stays on – and safe. Because failure just
isn’t an option.

LIGHTING

Lighting
Lighting

Lighting

Description

Page

Enclosed and Gasketed — Area — HID
Mercmaster™ III Luminaires Family Tree

920

Mercmaster™ III Low Profile Luminaires

922

Mercmaster™ III HID 50—250 Watt Luminaires

941

Mercmaster™ III 400 Luminaire for Hazardous
and Wet Locations

976

ATX LN Series Wellglass Luminaires

995

Mercmaster™ II HID Luminaires

1005

Mercmaster™ Jr. Luminaires

1021

MMIII Low Profile

MMIII 50-250

MMIII 400

LN Series

MMII

MM Jr.

MM LED

MMIII Induction

MMIII Low Profile

Enclosed and Gasketed — Area — LED/Induction
Mercmaster™ LED Luminaires

1028

Mercmaster™ III Induction Luminaires

1037

Enclosed and Gasketed — Area — Fluorescent
Mercmaster™ III Low Profile Compact
Fluorescent Luminaires

1055

FV™ Series Nonmetallic Fluorescent Luminaires

1070

FR™ Enclosed and Gasketed; FZ™ and FD™
Hazardous Locations Luminaires

1075

ATX FE Series Nonmetallic Fluorescent
Luminaires

1081

ATX FL Series Light Duty Nonmetallic
Fluorescent Luminaires

1095

ATX FN Series Heavy Duty Nonmetallic
Fluorescent Luminaires

1100

RigMaster™ Metallic Fluorescent Luminaires

1106

RigMaster™ 304 Stainless Steel Fluorescent
Luminaires

1111

VRS™ and DRS™ Fluorescent Luminaires

1113

FV Series

FR Series

FL Series

FN Series

RigMaster™ Metallic

RigMaster™ 304 Stainless Steel — V

V

Enclosed and Gasketed — Area — Recessed Fluorescent
RE Series Recessed Fluorescent Luminaires

1119

VRS/DRS
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

913

Lighting

Lighting

Lighting

Description

Page

Enclosed and Gasketed — Area — Incandescent
Stylmaster™ Incandescent Luminaires

1126

V—51 Incandescent Luminaires

1135

REA™ 150 W Incandescent Luminaires

1147

®

Stylmaster

V—51

REA

Areamaster 100

Areamaster 250/400

Areamaster 1000

PN Series

Corroflood

Wallmaster — V

Enclosed and Gasketed — Floodlight
Areamaster™ 100 Wide—Beam Floodlights

1149

Areamaster™ 250/400 Integrally Ballasted
Floodlights

1155

Areamaster™ 1000 Floodlights

1162

ATX PN Series Floodlights – Zone 2, 21 and 22

1166

Corroflood™ 250/400 Stainless Steel Floodlights

1171

Wallmaster I/2 for Hazardous and Wet Locations
— Class I, Division 2/Zone 2

1174

V

TVA Obstruction, Approach and Boundary
Luminaires

1176

V

Stylmaster™ Strobe Luminaires

1180

Enclosed and Gasketed — Visual Signal

Enclosed and Gasketed — Emergency
Mercmaster™ III Emergency Battery Pack

1184

N2LS™ Series Emergency Luminaires

1200

Explosionproof — Area — HID
Code•Master Jr.™ HID Factory Sealed
Luminaires

1205

Code•Master 2™ HID Factory Sealed Luminaires

1216

TVA — V

Stylmaster Strobe MMIII Emergency
Battery Pack

N2LS

Explosionproof — Area — Induction
Code•Master 2™ Induction Lighting System

1231

Code•Master Jr

914

Code•Master 2™

Code•Master 2 Induction

Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

Lighting
Lighting

Lighting

Description

Page

Explosionproof — Area — Fluorescent
Code•Master™ PLT Factory Sealed Luminaires

1240

APL Two and Four Lamp Fluorescent Factory
Sealed Luminaires

1252

EFU Fluorescent Factory Sealed Luminaires

1256

PAPL Portable Two and Four Lamp Fluorescent
Factory Sealed Luminaire

1260

ATX FD Series Cylindrical Fluorescent
Luminaires

1262

Code•Master PLT

APL

EFU

Explosionproof — Area — Incandescent
Code•Master™ Incandescent Factory Sealed
Luminaires

1269

A—51 Incandescent Factory Sealed Luminaires

1274

EDT Incandescent Luminaires

1288

®

PAPL

FD Series

Explosionproof — Floodlight
Code•Master 2™ HID Factory Sealed Floodlights

1289

EFL Series HID and Quartz Floodlights

1297

PB, PC & PL Series

1300

Explosionproof Floodlights

1306

V

Code•Master

A-51

EDT

Code•Master 2

EFL/PB/PC/PL

Explosionproof

Code•Master Strobe

TCH Series

AHL

Explosionproof — Visual Signal
Code•Master™ Factory Sealed Strobe
Luminaires

1308

Explosionproof — Portable
TCH Series Safety Flashlights

1314

AHL and EHL Incandescent Factory Sealed
Luminaires and Handlamps

1316

Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

915

Lighting

Lighting

Lighting

Description

Page

Explosionproof — Emergency
Code•Master 2™ Emergency PLT Factory
Sealed Luminaires

1318

ELS Series Emergency Lighting System

1327

Increased Safety/Flameproof — Bulkhead
ATX HBE Series Round Bulkhead Luminaires

1133

ATX HBD Series Bulkhead Luminaires

1336

ATX HBN Series Round Bulkhead Luminaires

1341

ATX HBDC Series Cylindrical Bulkhead
Luminaires

1344

Code•Master 2 Emergency PLT

General Lighting — Area — High Bay

HBE/HBN Series

Baymaster 250/400™ High Bay Luminaires

1347

Baymaster Prismatic 250/400™ High Bay
Luminaires

1353

Super-Baymaster High Bay Luminaires

1358

Baymaster 1000™ High Bay Luminaires

1361

ELS Series

HBD Series

HBDC Series

V

General Lighting — Area — Low Bay
Lumenmaster 250™ Low Bay HID Prismatic
Luminaires

1365

Lumenmaster 400™ Low Bay HID Prismatic
Luminaires

1370

Baymaster
250/400

Baymaster
SuperPrismatic 250/400 Baymaster — V

Baymaster 1000

General Lighting — Area — Floodlights
Quartzlite™ 50 Floodlight

1375

Quartzlite™ 500/1500 Floodlight

1376

Areamaster Jr.™ HID Wide-Beam Floodlights

1379

Beam-Master™ Floodlights

1383

Lumenmaster 250

Quartzlite 50/500

916

Lumenmaster 400

Areamaster Jr

Beam-Master

Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

Lighting
Lighting

Lighting

Description

Page

General Lighting — Area — Architectural
Wallmaster™ HPS/PSMH Luminaires

1386

Wallmaster™ 400 HPS/PSMH Luminaires

1390

Areamaster Squarelite™ 400 Sharp Cutoff
Luminaires

1395
Wallmaster

Wallmaster 400

Areamaster Squarelite

General Lighting — Area — Poles and Hangers
Round Tapered Steel Poles

1499

Hinged Steel Poles

1400

Square Tapered Steel Poles

1401

Square Steel Poles

1402

Floodlight Mounting Brackets

1403

UNJ

AL

JB

SSH

Flexible Fixture Hangers — Ordinary Location
AHG and UNJ Flexible Fixture Hangers

1407

AL Ball and Cushion Flexible Fixture Hangers

1408

JB and GS Flexible Fixture Hangers

1412

SSH Flexible Fixture Hangers

1414

SHC Flexible Fixture Hangers

1416

Flexible Fixture Hangers — Hook and Loop

1417

Flexible Fixture Hangers — Receptacle and
Hook and Loop

1420

Power Hook for Industrial High Bay Luminaires

1421

V

BKX Rigid Fixture Hangers

1422

CPU and EFHU Fixture Hangers

1424

V

Flexible Fixture Hangers, EXJF Couplings, ESD
and ESS Swivels

1427

EFHC and EFHCA Fixture Hangers and
Accessories

1430

GRF Conduit Outlet Boxes and Fixture Hanger
Covers and Canopies

1432

Fixture Hanger Bracket and Accessories

1434

Mounting Poles

SHC

Hook and Loop

Receptacle and
Power Hook — V
Hook and Loop

Flexible Fixture Hangers — Explosionproof

Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

BKX

CPU

ESD

EFHC

GRF

Bracket

917

Lighting

Lighting

Lighting

Description

Page

McGill Temporary
HID Temporary Lighting

1436

String-O-Lights

1437

7000 Series Industrial Extension Lights

1439

7000-38 Series Industrial Extension Lights

1442

6000 Series Commercial-Duty Extension Lights

1443

5000 Series Industrial Extension Lights

1444

Industrial Extension Lights

1446

Handy Compact Fluorescent Work Light

1447

Rough Service Fluorescent Lamp

1448

Fluorescent Work Lights

1449

Battery Pack with Charger

1450

Fluorescent Industrial Extension Lights

1451

High Intensity Low-Voltage Extension Lights

1452

Mini-Powerpak Low-Voltage Extension Lights

1453

Fluorescent Hand Lamps — Explosionproof

1454

Tubular Fluorescent Inspection Light —
Explosionproof

1455

Industrial Extension Lights — Explosionproof

1456

Low-Voltage, High Intensity Hand Lamp —
Explosionproof

1457

HID Temp

String-O-Lights

7000/6000/5000
Extension Lights

Handy Compact

Rough Service

Fluorescent Work

Battery Pack

Industrial Extension
Lights

High Intensity

Mini-Powerpak

Hand Lamp

Tubular Inspection Light

Industrial Extension Lights

918

Low-Voltage,
High Intensity Hand Lamp

Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

Lighting
Lighting

Lighting

Description

Page

McGill General
Incandescent Utility Lights

1458

Fluorescent Utility Lights

1460

McGill Lamp Protection
Protect-O-Sleeves

1461

Protect-O-Tubes

1463

Tubeloc Holders

1464

Protect-O-Globes

1465

Wire Lamp Guards and Wire Lamp Guard
Grounding Kit

1466

Utility Lights

Protect-O-Sleeves

Protect-O-Tubes

Tubeloc Holders

Protect-O-Globes

Wire Lamp Guard

McGill Lamp Changers
Fluorescent Lamp Changers

1467

Incandescent Lamp Changers

1468

Lamp Changer Accessories and Replacement
Parts

1470
Lamp Changers

Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

919

Mercmaster™ III Luminaires Family Tree

Flexible
Pendant Mount

Pendant Mount
KPA75
KPA100

Ceiling Mount

25° Stan

KPC75
KPC100

KPCH75
KPCH100

K
K

Lighting: Enclosed and Gasketed — Area — HID

Lighting

KPAF75
KPAF100

Cone
Pendant Mount

POLYMERIC
REFRACTORS

NEMA 2 LPRF-2CP
NEMA 3 LPRF-3CP
NEMA 4 LPRF-4CP
NEMA 5 LPRF-5CP

MLBG SERIES
50 W-150 W HPS
50 W-175 W PSMH
Med. Base
26-84 W Fluorescent

5.50"/
139.7mm

• Fluorescent
• Metal Halide
100W Max.
(Lamp Extender
not required)

Standard Dome
CMR-4ST *

Deep Dome
CMR-4DD *

7.75"/
196.9mm

MLBR SERIES
50 W-150 W HPS
50 W-175 W PSMH
Med. Base
26-84 W Fluorescent

KPB SERIES
50 W-150 W HPS
100 W, 175 W,
200 W, 250 W PSMH (KPBG)
Mogul Base
5.50"/
139.7mm

Metal Halide
100W Max
Lamp Extender

30° Angle
CMR-4AN

GLASS REFRACTORS
Standard Dome Deep Dome
KR2-ST
KR2-DD

Standard Dome
CMR-4ST *

NEMA 1 LPG-R1
NEMA 3 LPG-R3
NEMA 5 LPG-R5

30° Angle
KR2-AN

POLYMERIC
REFRACTORS

NEMA 2 LPRF-2CP
NEMA 3 LPRF-3CP
NEMA 4 LPRF-4CP
NEMA 5 LPRF-5CP

KRG2
Refractor Guard
GLASS GLOBE

HID GLASS GLOBE
Clear
Amber
Blue
Green
Red

VPGL-1HR
VPGL-1AM
VPGL-1BL
VPGL-1GR
VPGL-1RE

5.63"/
143.0mm

GLASS GLOBE

Clear VPGL-3HR

Fluorescent
Clear VPGL-2HR
Amber VPGL-2AM
Blue VPGL-2BL
Green VPGL-2GR
Red VPGL-2RE

8.00"/
203.2mm

KGU1
HID
GlobeGuard

8.50"/
215.9mm

KGU2
Fluorescent
Globe Guard

(for 100 W HPS only)

Standard Dome
KR2-ST

Deep Dome
KR2-DD

GLASS GLOBE

6.75"/171.5mm

EXIT

Clear
Amber
Blue
Green
Red

9.25"/
235.0 mm

VPGL-2HR
VPGL-2AM
VPGL-2BL
VPGL-2GR
VPGL-2RE

KGU2
Globe Guard

Three-Way Exit Sign
CJEXRN

5.75"/146.1mm
DIA.

30° Angle
KR2-AN

5.69”/
144.5mm

* Standard and deep dome reflectors may interfere with bottom conduit entry if used with KPST and KPWB mounting hoods.
11.38"/
289.1mm

920
6.63”/
168.4mm
13.25"/336.6mm

Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

KRG2
Refractor Guard

Mercmaster™ III Luminaires Family Tree

ing Mount

25° Stanchion Mount

KPC75
KPC100

KPS125
KPS150

90° Stanchion Mount
KPST125
KPST150

Wall Mount
KPWB75
KPWB100
Lighting

0"/
7mm

KPBR SERIES
50 W-150 W HPS
100 W, 175 W,
200 W, 250 W PSMH
Mogul Base

7.75"/
196.9mm

7.75"/
196.9mm

Metal Halide
100W Max
Lamp Extender

Standard Dome
CMR-4ST*

Standard Dome Deep Dome
CMR-4ST *
CMR-4DD *

30° Angle
CMR-4AN

OLYMERIC
FRACTORS

MA 2 LPRF-2CP
MA 3 LPRF-3CP
MA 4 LPRF-4CP
MA 5 LPRF-5CP

GLASS GLOBE

Clear VPGL-3HR
(for 100 W HPS only)

GLASS REFRACTORS
NEMA 1 LPG-R1
NEMA 3 LPG-R3
NEMA 5 LPG-R5

GLASS REFRACTORS
30° Angle
CMR-4AN

VPGL-2HR
VPGL-2AM
VPGL-2BL
VPGL-2GR
VPGL-2RE

NEMA 2 KPRF-400-2
NEMA 3 KPRF-400-5

Clear VPGL-4HR

KPBG-12
12” Wire Guard

KRG2
Refractor Guard

KRG2
Refractor Guard

16” Lens
Enclosed Reflector
KPR-4HB

GLASS GLOBE

30° Angle
KR2-AN

GLASS GLOBE

Clear
Amber
Blue
Green
Red

KPB400 SERIES
250 W-400 W HPS
250 W, 320 W, PSMH
350 W, 400 W PSMH
Mogul Base

GHB7000-NG
16” Wire Guard

KPGU400
Globe Guard

GU2
lobe Guard

* Standard and deep dome reflectors may interfere with bottom conduit entry if used with KPST and KPWB mounting hoods.
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

921

Lighting: Enclosed and Gasketed — Area — HID

KPB SERIES
50 W-150 W HPS
100 W, 175 W,
200 W, 250 W PSMH (KPBG)
Mogul Base

Mercmaster™ III Low Profile Luminaires

High Pressure Sodium and Pulse Start Metal Halide

Listed for simultaneous exposure to combustible dusts and flammable gases or vapors.
Class I, Division 2, Groups A, B, C, D
Class I, Zone 2, AEx nA nR IIC (Z2)
Class I, Zone 2, Ex nR IIC (Z) V
Class I, Zone 2, AEx nR IIC (ZB)

Class II, Division 1 and 2, Groups E, F, G
Class III
Simultaneous Exposure (Class I, Division 2/
Class II, Division 1)

Fixtures Outside Type (Salt Water)
Type 4X
IP66

Lighting: Enclosed and Gasketed — Area — HID

Lighting

Applications
•	 Enclosed and gasketed fixtures suitable for use in:
— Marine and wet locations
— A wide range of industrial, chemical processing and other
areas where flammable gases and vapors or combustible
dusts are present under conditions defined by the National
Electrical Code as Class I, Division 2; Class II, Division 1 and
2; and Class III
—	Areas of low clearance, low ceiling heights or where fixture
weights must be minimized
— For Zone 2, the method of protection is AEx nA nR –
Restricted Breathing/Nonsparking or AEx nR – Restricted
Breathing
— Non-hazardous locations where severe weather conditions,
excessive moisture, dirt, dust, corrosive atmosphere or high
ambient temperatures are encountered
•	 Typical applications include:
— Pulp and paper mills
— Processing plants
— Chemical plants
— Oil refineries
— Foundries
— Manufacturing plants
— Storage areas
— Waste and sewage treatment
— Parking garages
— Other areas where dust, water, dirt and rough usage are a
problem

Features
•	 Compact light weight low profile design is suited for low
mounting heights in conjunction with lower wattage fixtures.
•	 Modular design allows scores of fixture component combinations
to meet installation and lighting needs. Uses same mounting
hoods and optical accessories as Mercmaster III.
•	 A choice of heat-resistant prismatic glass refractors (NEMA I, III
or V) or heat-resistant globes which thread directly into ballast
housing. Photometrics available upon request ­– contact your
local sales representative.
•	 Standard dome or 30° angle reflectors made of fiberglass
reinforced white polyester. Highly resistant to corrosive
atmospheres.
•	 Accommodates medium base lamps.
•	 A wide range of voltages available (120 to 600 Volt) and ballast
types (Reactor, CWA, CWI and Super CWA).
•	 Medium base lamp type and watts:
	 — HPS 50 W-150 W
	 — PSMH 50 W-175 W
•	 Hinge has high lip for added safety during installation
and servicing. Hinge and bolt construction assures 360º
compression at all points on ballast housing gasket for positive
sealing. Swing away design of captive bolt and nut simplifies
servicing.
•	 All Mercmaster III mounting hoods have provision for easy field
installation of fuses in fixtures (see fuse kits).
•	 Fixtures are for use in Class I, Zone 2 hazardous locations.
•	 The AEx nA nR / Ex nR (V) factory sealed Mercmaster III
prevents vapors and gases from entering the globe chamber.
There are no seals or putty required which will reduce
installation time and installation errors.

Low Profile Mercmaster III with Prismatic Globe and Guard

Standard Materials
•	 Mounting hoods, bodies and guard: cast copperfree 	
(4/10 of 1% max.) aluminum
•	 All hardware and catch assemblies: stainless steel
•	 Reflectors: Fiberglass reinforced white polyester
•	 Globes and Refractors: heat-resistant prismatic glass

Standard Finishes
•	 Mounting hoods, bodies and guards: baked gray epoxy-clad
finish, electrostatically applied for complete uniform protection

Options
•	 Quartz Auxiliary comes to full brightness immediately and
remains lit until the HID lamp attains 60-70% of full illumination.
Quartz Auxiliary supplied with relay switch and socket to accept
120 V quartz double-contact bayonet base lamp (not included).
Add suffix -E †.
•	 Guards with gray epoxy painted to match fixtures, supplied with
stainless steel screws. Add suffix -G before voltage suffix.
•	 Hot Restrike to restrike HPS lamp immediately when power is
restored after a momentary power interruption. Add suffix -R.
•	 Smart Starter incorporates a 1-1/2 minute timer and performs
as a conventional starter to normally start lamp. Removes
itself from circuit if lamp burns out or is removed from socket.
Eliminates starter failures caused by prolonged operation with
cycling or failing lamps and simplifies finding their location,
reducing maintenance and repair costs. Available for all fixtures.
Add suffix -S.
•	 Smart Hot Restrike will immediately restrike HPS lamp when
power is restored after a momentary power interruption. The
smart function removes the hot restrike ignitor from the circuit
if the lamp burns out or is removed from the socket. Eliminates
starter failures caused by prolonged operation with cycling or
failing lamps. Add suffix -SR.
•	 AEx nA nR fixtures, add suffix -Z2.
•	 AEx nR fixtures, add suffix -ZB.
•	 Ex nR fixtures, add suffix -Z V.
•	 Reflectors are available as standard dome and 30° angle
polyester. Order separately.

† Fixtures equipped with quartz auxiliary lamp do not comply with NEC/CEC V requirements and are not suitable for use in classified locations.
V CSA Certification Only.

922

Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

Mercmaster™ III Low Profile Luminaires

High Pressure Sodium and Pulse Start Metal Halide

Listed for simultaneous exposure to combustible dusts and flammable gases or vapors.
Class I, Division 2, Groups A, B, C, D
Class I, Zone 2, AEx nA nR IIC (Z2)
Class I, Zone 2, Ex nR IIC (Z) V
Class I, Zone 2, AEx nR IIC (ZB)

Class II, Division 1 and 2, Groups E, F, G
Class III
Simultaneous Exposure (Class I, Division 2/
Class II, Division 1)

Certifications and Compliances *

Fixtures Outside Type (Salt Water)
Type 4X
IP66

Related Products
•	 Photocells for classified use are available, see PCD2 Series.

Lighting

•	 UL Listed: 60079-15
•	 UL Standard: 1598A, UL 844, Marine Type Electric Fixtures
Outside Type (Salt Water)
•	 CSA Certified: LR25428

Order using catalog numbering guide below or select catalog number from tables on following pages.
Catalog Numbering Guide

Series:
ML Mercmaster III	
Low Profile

A

L
Lamp Type:
I - Incandescent
L - High Pressure
	 	  Sodium
H or P - Pulse Start
Metal Halide
H - 175 W Metal
Halide (available
with TT voltage
only) V

Mounting:
	A - Pendant (rigid
mounting)
	C - Ceiling
	D - Pendant Cone Hood
	F - Pendant (flexible	
mounting)
	R - 90° Stanchion
	S - 25° Stanchion
	W	 - Wall

15

2

G1

Hub Size:
2 - 3/4” NPT
3 - 1” NPT
4 - 1-1/4” NPT
stanchion
5 - 1-1/2” NPT
stanchion

Wattage:
10 - 100 W HPS, PSMH
15 - 150 W HPS, PSMH
and 60-150 W max.
Incandescent
17 - 175 W PSMH
17 - 175 W MH V
50 - 50 W HPS, PSMH
70 - 70 W HPS, PSMH

G

MT

R

Z2

Guard Options:
G - Cast Guard
N - No Guard

Optical Assembly: ➋
G1 - Globe
J1 - NEMA I Glass
Refractor
J3 - NEMA III Glass
Refractor
J5 - NEMA V Glass
Refractor
P2 - NEMA II Polymeric
Refractor
P3 - NEMA III Polymeric
Refractor
P4 - NEMA IV Polymeric
Refractor
P5 - NEMA V Polymeric
Refractor

Options:
E - Emergency Quartz ➎
F - Fuse Kit (Specify
Voltage) ➏
R - Hot Restrike ➌
S - Smart Starter ➍
SR - Smart Hot 	
Restrike ➌
H1 - Photocontrol 120 V
H2 - Photocontrol 208 V
H3 - Photocontrol 240 V
H4 - Photocontrol 277 V
C - Safety Cable
Adapted V
D - E-27 Export Socket
T - Terminal Blocks V
V - Anti-Vibration
Modifications V
X - Appledapter ➐
Mounting Hood
Adapter V
Suffix:
Voltage: ➊
LB - Incandescent, 120,
Z2 - Zone 2 suffix
60 Hz
(required for
MT - 120/208/240/277,
AEx nA nR
60 Hz
rating)
5MT - 120/208/240/
ZB - Zone 2 suffix
277/480, 60 Hz
(required for
48 - 480, 60 Hz
AEx nR)
125	- 120, 50 Hz
Z - Zone 2 suffix
225	- 225, 50 Hz
226	- 220, 60 Hz
(required for 	
245	- 240, 50 Hz
Ex nR) V
C2 - 208, 60 Hz, CWI V
C3 - 240, 60 Hz, CWI V
C6 - 480, 60 Hz, CWI V
C7 - 600, 60 Hz, CWI V
TT - 120/277/347, 60 Hz,
CWA V

* Compliance data varies for specific fixtures. Consult Appleton regarding suitability of specific fixtures for a particular application.
➊ Other voltages, frequencies available – contact your local sales representative. Voltages shown are limited to specific combinations; refer to following pages.
➋ Polymeric Refractor suitable for Class II, Groups F and G, NEMA 4X and Marine Type Electric Fixtures Outside Type (Salt Water) only (100 W PSMH Max.).
Reflectors ordered separately.
➌ Available for 50-150 W HPS fixtures only.
➍ Available for HPS or PSMH fixtures.
➎ Not suitable for hazardous location per NEC/CEC V.
➏ Canadian Electrical Code does NOT allow fusing in hazardous locations V.
➐ Appledapter is available for use with the pendant, ceiling and angled stanchion mounting only.
V CSA Certification Only.
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

923

Lighting: Enclosed and Gasketed — Area — HID

ML

Mercmaster™ III Low Profile Luminaires

High Pressure Sodium and Pulse Start Metal Halide

Listed for simultaneous exposure to combustible dusts and flammable gases or vapors.
Class I, Division 2, Groups A, B, C, D
Class I, Zone 2, AEx nA nR IIC (Z2)
Class I, Zone 2, Ex nR IIC (Z) V
Class I, Zone 2, AEx nR IIC (ZB)

Class II, Division 1 and 2, Groups E, F, G
Class III
Simultaneous Exposure (Class I, Division 2/
Class II, Division 1)

Fixtures Outside Type (Salt Water)
Type 4X
IP66

Lighting: Enclosed and Gasketed — Area — HID

Lighting

Illustrated Features

Vented Reflectors
Reflectors are thick, tough fiberglass-	
reinforced white polyester, vented for
cooler operation. Quickly attach with
furnished stainless steel screws.
High Temperature Sockets
Medium base high-temperature porcelain
sockets.
Aluminum Inner Reflector
Solid aluminum inner reflector (for
refractor ballast housings only) improves
photometric efficiency.
Globe Chamber
Completely sealed from the ballast
housing and outside vapors/air (nR).
Electrical Protection
Ground wire provided to bond mounting
hood to ballast housing.

Fuses
Two screws secure fuse kit to mounting
boss in any Mercmaster mounting hood.
Fuse included.
Photocell
Available for all fixtures except cone and
ceiling mount. Installs through knock-out
in mounting hood. Provides continuous
ON-OFF dusk-to-dawn control.

Stainless Steel Inserts
Ballast bodies have stainless steel
threaded inserts to receive stainless steel
screws for reflectors and guard. Prevents
"freezing”, allowing guards and reflectors
to be easily removed and replaced at any
time, without damage to the housing.
Epoxy Finish
Ballast housing, hoods and guards are
copperfree aluminum with epoxy powder
coat finish.
Prismatic Glass Globes and Refractors
Heat-resistant globes and refractors
thread directly into ballast housing and
seal against a high-temperature	
silicone rubber gasket.

Ballast Assembly
Utilizing non-sparking components
avoiding the ignition of gases or vapors
that may be present (nA).
Mounting Hood and Globe Gaskets
Silicone rubber gaskets seals out
moisture, dirt and dust. Stays flexible,
withstands high temperatures. Closure
design assures uniform gasket
compression.
Terminal Blocks (Zone 2)
A seven-point terminal block is provided
to facilitate wiring. Terminal block
accommodates wire size ranging from #8
to #24 AWG.

Cooler Operating Cone Hood
Larger sloped surface sheds dusts, dirt
and combustible fibers providing better
heat dissipation.
"Safety" High
Hinge
Extra-high hinge
provides additional
protection against
accidental
ballast housing
disengagement
during installation or
maintenance.

Stainless Steel
Latch Assembly
Captive, stainless
steel latch
assembly bolt
and nut closes
securely, resists
attack of corrosive
atmospheres.
Swing-away design
simplifies servicing.

V CSA Certification Only.

924

Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

Mercmaster™ III Low Profile Luminaire Thermal Performance

Class I, Division 2; Class II, Division 1; Simultaneous exposure to hazardous conditions in both classifications
Temperature identification numbers of Mercmaster III Low Profile High Pressure Sodium and Pulse Start Metal Halide
Class I, Division 2, Groups A, B, C, D
Class I, Zone 2, AEx nA nR IIC (Z2)
Class I, Zone 2, Ex nR IIC (Z) V
Class I, Zone 2, AEx nR IIC (ZB)

Lamp

50

70

HPS

HPS

HPS

Class II, Division 1
Groups E, F and G

Simultaneous Exposure
Class I, Division 2 / Class II, Division 1

Supply
Wire
Temp.
(°F/°C)

Ambient
Temp.
(°F/°C)

Globe

Globe &
Reflector

Refractor

Globe

Globe &
Reflector

Refractor

Globe

Globe &
Reflector

194/90

104/40

T3

T3

T3B

T4A

T4A

T5

T3

T3

T3

194/90

131/55

T3

T3

T3A

T4A

T4A

T4A

T2D

T2D

T2D

194/90

149/65

T3

T3

T3A

T4

T4

T4A

T2C

T2C

T2C

194/90

104/40

T3

T3

T3

T4

T4

T5

T2B

T2B

T2D

194/90

131/55

T2D

T2D

T3

T3C

T3C

T4A

T2B

T2B

T2C

Class I, Division 2

Refractor

194/90

149/65

—

—

T3

—

—

T4

—

—

T2B

194/90

104/40

T2C

T2C

T2D

T4

T4

T4A

T2B

T2B

T2B

194/90

131/55

T2B

T2B

T2C

T3C

T3C

T4

T2A

T2A

T2A

194/90

149/65

—

—

—

—

—

—

—

—

—

104/40

T2A

T2A

T2B

T3A *

—

T4

325

—

T2

150

HPS

194/90
194/90

104/40

T3

T3

T3A

T4A

T4A

T6

T2D

T2D

T3

50

PSMH

194/90

131/55

T3

T3

T3

T4

T4

T5

T2C

T2C

T2D

70

PSMH

194/90

149/65

T3

T3

T3

T4

T4

T4A

T2B

T2B

T2D

194/90

104/40

T3

T3

T3

T3C

T3C

T4A

T2B

T2B

T2C

194/90

131/55

T2D

T2D

T3

T3C

T3C

T4A

T2A

T2A

T2B

230/110

149/65

—

—

T3

—

—

T4

—

—

T2B

194/90

104/40

T2A

T2A

T2B

T3B

T3B

T4A

T2

T2

T2A

100

PSMH

194/90

131/55

T2A

T2A

T2B

T3A *

T3A *

T4

T1

T1

T2

150

PSMH 230/110

104/40

350

350

325

—

—

T3B

—

—

T1

175

PSMH 230/110

104/40

350

350

325

—

—

T3B

—

—

T1

175

MH V

230/110

104/40

—

—

325

—

—

T3B

—

—

—

194/90

104/40

T3B

T3B

T3C

—

—

—

—

—

—

194/90

131/55

T3A

T3A

T3C

—

—

—

—

—

—

194/90

149/65

T3A

T3A

T3C

—

—

—

—

—

—

194/90

104/40

T3

T3

T3

—

—

—

—

—

—

194/90

131/55

T3

T3

T3

—

—

—

—

—

—

194/90

149/65

T2D

T2D

T3

—

—

—

—

—

—

60

100

150

Inc.

Inc.

Inc.

194/90

104/40

T2D

T2D

T3

—

—

—

—

—

—

194/90

131/55

T2B

T2B

T2D

—

—

—

—

—

—

194/90

149/65

T2B

T2B

T2D

—

—

—

—

—

—

“T” Numbers Represent the Maximum Lamp Temperature for Class I, Division 2 Locations and
Maximum Surface Temperature Under Dust Blanket for Class II, Division 1 Locations.
“T” #

T1

350

325

T2

T2A

T2B

T2C

T2D

T3

T3A

T3B

T3C

T4

T4A

T5

T6

Temp.
Range
(˚ºF)

664842

619662

574617

538572

502536

448500

421446

394419

358392

331356

322329

277320

250275

214248

187212

185

Temp.
Range
(°C)

351450

326350

301325

281300

261280

231260

216230

201215

181200

166180

161165

136160

121135

101120

86100

85

* “T” numbers are for Groups E and F only.

V CSA Certification only.

Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

925

Lighting: Enclosed and Gasketed — Area — HID

100

Type

Fixtures Outside Type (Salt Water)
Type 4X
IP66

Lighting

Watts

Class II, Division 1 and 2, Groups E, F, G
Class III
Simultaneous Exposure (Class I, Division 2/
Class II, Division 1)

Mercmaster™ III Low Profile Luminaire Thermal Performance
Class I, Zone 2, AEx nA nR IIC, AEx nR IIC IP66, NEMA 4X

Temperature identification numbers of Mercmaster III Zone 2 Low Profile High Pressure Sodium and Pulse Start Metal Halide.
Class I, Division 2, Groups A, B, C, D
Class I, Zone 2, AEx nA nR IIC (Z2)
Class I, Zone 2, Ex nR IIC (Z) V
Class I, Zone 2, AEx nR IIC (ZB)

Class II, Division 1 and 2, Groups E, F, G
Class III
Simultaneous Exposure (Class I, Division 2/
Class II, Division 1)

Lamp

Lighting

Watts
50

HPS

70

Lighting: Enclosed and Gasketed — Area — HID

Type

HPS

100

HPS

150

HPS

50

PSMH

70

PSMH

100

PSMH

Supply Wire
Temp. (°F/°C)

Ambient
Temp. (°F/°C)

194/90

104/40

Fixtures Outside Type (Salt Water)
Type 4X
IP66

Class I, Zone 2 AEx nA nR IIC / Ex nR IIC
Globe w/
Globe
Reflector
Refractor
T6

T6

T6

Class I, Zone 2 AEx nR IIC
Globe w/
Globe
Reflector
Refractor
T6

T6

T6

194/90

131/55

T5

T5

T5

T5

T5

T5

194/90

149/65

T4

T4

T5

T4

T4

T5

194/90

104/40

T5

T5

T5

T5

T5

T5

194/90

131/55

T4

T4

T4

T4

T4

T4

194/90

149/65

—

—

T4

—

—

T4

194/90

104/40

T4

T4

T4

T4

T4

T4

194/90

131/55

T4

T4

T4

T4

T4

T4

194/90

104/40

T4

T4

T4

T4

T4

T4

194/90

104/40

T5

T5

T6

T5

T5

T6

194/90

131/55

T5

T5

T6

T5

T5

T6

194/90

149/65

T4

T4

T5

T4

T4

T5

194/90

104/40

T5

T5

T6

T5

T5

T6

194/90

131/55

T4

T4

T6

T4

T4

T6

230/110

149/65

—

—

T4

—

—

T4

194/90

104/40

T4

T4

T6

T4

T4

T6

194/90

131/55

T4

T4

T4

T4

T4

T4

150

PSMH

221/105

104/40

T3

T3

T4

T3

T3

T4

175

PSMH

221/105

104/40

T3

T3

T4

T3

T3

T4

175

MH V

230/110

104/40

—

—

T3

—

—

—

“T” Numbers represent the maximum surface temperature for luminaries with AEx nA nR, Ex nR and AEx nR rating:

The “T” number is established by separately determining the maximum temperature of the globe surface and ballast compartment. The hotter of the two is taken
to determine the “T” number for the overall fixture.

“T” Number

T1

T2

T3

T4

T5

T6

Temp. Range (°F)

547-842

394-572

277-392

214-275

187-212

185

Temp. Range (°C)

301-450

201-300

136-200

101-135

86-100

85

V CSA Certification Only.

926

Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

Mercmaster™ III Low Profile Luminaires
50 W – 150 W HPS

High Power Factor (min. P.F. 90%). Medium base lamps.
Class I, Division 2, Groups A, B, C, D
Class I, Zone 2, AEx nA nR IIC (Z2)
Class I, Zone 2, Ex nR IIC (Z) V
Class I, Zone 2, AEx nR IIC (ZB)

Class II, Division 1 and 2, Groups E, F, G
Class III
Simultaneous Exposure (Class I, Division 2/
Class II, Division 1)

Lamp Type

Lamp Watts

Hub Size
(Inches)

Fixtures Outside Type (Salt Water)
Type 4X
IP66

Catalog Numbers ➌➍➎➏
With Globe
With Type V 8” Refractor ➋

Pendant — One Hub, Rigid Mounting 

HPS

70

HPS

100

HPS

150

3/4

MLAL502G1N

1

MLAL503G1N

MLAL502J5N
MLAL503J5N

3/4

MLAL702G1N

MLAL702J5N

1

MLAL703G1N

MLAL703J5N

3/4

MLAL102G1N

MLAL102J5N

1

MLAL103G1N

MLAL103J5N

3/4

MLAL152G1N ➐

MLAL152J5N ➐

1

MLAL153G1N ➐

MLAL153J5N ➐

3/4

MLDL502G1N

MLDL502J5N

1

MLDL503G1N

MLDL503J5N

3/4

MLDL702G1N

MLDL702J5N

Lighting: Enclosed and Gasketed — Area — HID

Shown with Globe and Optional Guard

50

Lighting

HPS

Pendant Cone — One Hub, Rigid Mounting
HPS
HPS
HPS
Shown with Refractor

HPS

50
70
100
150

1

MLDL703G1N

MLDL703J5N

3/4

MLDL102G1N

MLDL102J5N

1

MLDL103G1N

MLDL103J5N

3/4

MLDL152G1N ➐

MLDL152J5N ➐

1

MLDL153G1N ➐

MLDL153J5N ➐

3/4

MLCL502G1N

MLCL502J5N

1

MLCL503G1N

MLCL503J5N

3/4

MLCL702G1N

MLCL702J5N

Ceiling — Five Hubs, Four Close-up Plugs
HPS
HPS
HPS
Shown with Globe

HPS

50
70
100
150

1

MLCL703G1N

MLCL703J5N

3/4

MLCL102G1N

MLCL102J5N

MLCL103G1N

MLCL103J5N

3/4

MLCL152G1N ➐

MLCL152J5N ➐

1

MLCL153G1N ➐

MLCL153J5N ➐

1

➊ For Flexible Pendant Mount, change A to F in catalog number (except 50 W HPS).
➋ To order fixture with NEMA Type I or NEMA Type III refractor, change final digit 5 in catalog number to 1 or 3.
➌ For fixtures with guards, substitute a G for the N before adding voltage suffix. See following pages for accessory ordering information.
➍ Add the following voltage and frequency designation before Z2 suffix:
Voltage Suffixes
Lamp Type Lamp Watts
LB
MT
5MT
48
125
225
226
235
245
C2 V
C3 V
C6 V
C7 V
TT V
Inc.
150 Max.
X
—
—
—
—
—
—
—
—
—
—
—
—
—
HPS
50
—
X
—
—
—
X
X
—
X
—
—
—
—
X
HPS
70
—
X
—
X
X
X
X
—
X
—
—
—
—
X
HPS
100
—
X
—
X
X
X
X
—
X
—
—
—
—
X
HPS
150
—
X
—
X
X
X
X
—
X
X
X
X
X
X
PSMH
50
—
X
—
X
—
—
—
—
—
—
—
—
—
X
PSMH
70
—
X
—
X
X
X
—
—
X
—
—
—
—
X
PSMH
100
—
X
—
X
X
X
—
—
X
—
—
—
—
X
PSMH
150
—
X
—
X
—
—
—
—
X
—
—
—
—
X
PSMH
175
—
X
X
X
—
—
—
—
X
—
—
—
—
X
175
—
X
—
—
—
—
—
—
—
X
X
X
X
X
MH V
Voltages:
LB - Incandescent, 120 V 60 Hz
125 - 120 V 50 Hz
245 - 240 V 50 Hz
MT - 120/208/240/277 V 60 Hz
225 - 225 V 50 Hz
C2 - 208 V 60 Hz, CWI V
226 - 220 V 60 Hz
C3 - 240 V 60 Hz, CWI V
C7 - 600 V 60 Hz, CWI V,
5MT - 120/208/240/277/480 V 60 Hz
48 - 480 V 60 Hz
235 - 230 V 50 Hz
C6 - 480 V 60 Hz, CWI V
TT - 120/277/347 V 60 Hz, CWA V
➎ Add Z2 suffix for factory sealed non-sparking/restricted breathing protection (AEx nA nR). Add ZB suffix for restricted breathing protection (AEx nR).
➏ Add Z for factory sealed restricted breathing protection (Ex nR) V.
➐ For 150 W HPS fixtures, use S-55 lamp type only.
V CSA Certification Only.
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

927

Mercmaster™ III Low Profile Luminaires
50 W – 150 W HPS

High Power Factor (min. P.F. 90%). Medium base lamps.
Class I, Division 2, Groups A, B, C, D
Class I, Zone 2, AEx nA nR IIC (Z2)
Class I, Zone 2, Ex nR IIC (Z) V
Class I, Zone 2, AEx nR IIC (ZB)

Class II, Division 1 and 2, Groups E, F, G
Class III
Simultaneous Exposure (Class I, Division 2/
Class II, Division 1)

Lighting: Enclosed and Gasketed — Area — HID

Lighting

Lamp Type
Wall ­— Five Hubs, Four Close-Up Plugs

Shown with Refractor and Optional Guard

Lamp Watts

HPS

50

HPS

70

HPS

100

HPS

150

HPS

50

Hub Size
(Inches)

Fixtures Outside Type (Salt Water)
Type 4X
IP66

Catalog Numbers ➌➍➎➏
With Globe
With Type V 8” Refractor ➋

3/4

MLWL502G1N

MLWL502J5N

1

MLWL503G1N

MLWL503J5N

3/4

MLWL702G1N

MLWL702J5N

1

MLWL703G1N

MLWL703J5N

3/4

MLWL102G1N

MLWL102J5N

1

MLWL103G1N

MLWL103J5N

3/4

MLWL152G1N ➐

MLWL152J5N ➐

1

MLWL153G1N ➐

MLWL153J5N ➐

1-1/4

MLSL504G1N

MLSL504J5N

1-1/2

MLSL505G1N

MLSL505J5N

1-1/4

MLSL704G1N

MLSL704J5N

25° Stanchion —
­ One Hub

HPS
HPS

Shown with Globe and Optional Guard
90° Stanchion —
­ One Hub

100

HPS

150

HPS

50

HPS
HPS

Shown with Refractor and Optional Guard

70

HPS

70
100
150

1-1/2

MLSL705G1N

MLSL705J5N

1-1/4

MLSL104G1N

MLSL104J5N

1-1/2

MLSL105G1N

MLSL105J5N

1-1/4

MLSL154G1N ➐

MLSL154J5N ➐

1-1/2

MLSL155G1N ➐

MLSL155J5N ➐

1-1/4

MLRL504G1N

MLRL504J5N

1-1/2

MLRL505G1N

MLRL505J5N

1-1/4

MLRL704G1N

MLRL704J5N

1-1/2

MLRL705G1N

MLRL705J5N

1-1/4

MLRL104G1N

MLRL104J5N

1-1/2

MLRL105G1N

MLRL105J5N

1-1/4

MLRL154G1N ➐

MLRL154J5N ➐

1-1/2

MLRL155G1N ➐

MLRL155J5N ➐

➊ For Flexible Pendant Mount, change A to F in catalog number (except 50 W HPS).
➋ To order fixture with NEMA Type I or NEMA Type III refractor, change final digit 5 in catalog number to 1 or 3.
➌ For fixtures with guards, substitute a G for the N before adding voltage suffix. See following pages for accessory ordering information.
➍ Add the following voltage and frequency designation before Z2 suffix:
Voltage Suffixes
Lamp Type Lamp Watts
LB
MT
5MT
48
125
225
226
235
245
C2 V
C3 V
C6 V
C7 V
TT V
Inc.
150 Max.
X
—
—
—
—
—
—
—
—
—
—
—
—
—
HPS
50
—
X
—
—
—
X
X
—
X
—
—
—
—
X
HPS
70
—
X
—
X
X
X
X
—
X
—
—
—
—
X
HPS
100
—
X
—
X
X
X
X
—
X
—
—
—
—
X
HPS
150
—
X
—
X
X
X
X
—
X
X
X
X
X
X
PSMH
50
—
X
—
X
—
—
—
—
—
—
—
—
—
X
PSMH
70
—
X
—
X
X
X
—
—
X
—
—
—
—
X
PSMH
100
—
X
—
X
X
X
—
—
X
—
—
—
—
X
PSMH
150
—
X
—
X
—
—
—
—
X
—
—
—
—
X
PSMH
175
—
X
X
X
—
—
—
—
X
—
—
—
—
X
175
—
X
—
—
—
—
—
—
—
X
X
X
X
X
MH V
Voltages:
LB - Incandescent, 120 V 60 Hz
125 - 120 V 50 Hz
245 - 240 V 50 Hz
MT - 120/208/240/277 V 60 Hz
225 - 225 V 50 Hz
C2 - 208 V 60 Hz, CWI V
226 - 220 V 60 Hz
C3 - 240 V 60 Hz, CWI V
C7 - 600 V 60 Hz, CWI V,
5MT - 120/208/240/277/480 V 60 Hz
48 - 480 V 60 Hz
235 - 230 V 50 Hz
C6 - 480 V 60 Hz, CWI V
TT - 120/277/347 V 60 Hz, CWA V
➎ Add Z2 suffix for factory sealed non-sparking/restricted breathing protection (AEx nA nR). Add ZB suffix for restricted breathing protection (AEx nR).
➏ Add Z for factory sealed restricted breathing protection (Ex nR) V.
➐ For 150 W HPS fixtures, use S-55 lamp type only.
V CSA Certification Only.

928

Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

Mercmaster™ III Low Profile Luminaires
50 W - 175 W PSMH

High Power Factor (min. P.F. 90%). Medium base lamps.
Class I, Division 2, Groups A, B, C, D
Class I, Zone 2, AEx nA nR IIC (Z2)
Class I, Zone 2, Ex nR IIC (Z) V
Class I, Zone 2, AEx nR IIC (ZB)

Class II, Division 1 and 2, Groups E, F, G
Class III
Simultaneous Exposure (Class I, Division 2/
Class II, Division 1)

Lamp Type

Lamp Watts

Hub Size
(Inches)

Fixtures Outside Type (Salt Water)
Type 4X
IP66

Catalog Numbers ➌➍➎➏
With Globe
With Type V 8” Refractor ➋

Pendant ­— One Hub, Rigid Mounting 

PSMH

70

PSMH

100

PSMH

150

PSMH

175

3/4
1
3/4
1
3/4
1
3/4
1
3/4
1

MLAH502G1N
MLAH503G1N
MLAH702G1N
MLAH703G1N
MLAH102G1N
MLAH103G1N
MLAP152G1N
MLAP153G1N
MLAP172G1N
MLAP173G1N

MLAH502J5N
MLAH503J5N
MLAH702J5N
MLAH703J5N
MLAH102J5N
MLAH103J5N
MLAP152J5N
MLAP153J5N
MLAP172J5N
MLAP173J5N

3/4
1
3/4
1
3/4
1
3/4
1
3/4
1

MLDH502G1N
MLDH503G1N
MLDH702G1N
MLDH703G1N
MLDH102G1N
MLDH103G1N
MLDP152G1N
MLDP153G1N
MLDP172G1N
MLDP173G1N

MLDH502J5N
MLDH503J5N
MLDH702J5N
MLDH703J5N
MLDH102J5N
MLDH103J5N
MLDP152J5N
MLDP153J5N
MLDP172J5N
MLDP173J5N

3/4
1
3/4
1
3/4
1
3/4
1
3/4
1

MLCH502G1N
MLCH503G1N
MLCH702G1N
MLCH703G1N
MLCH102G1N
MLCH103G1N
MLCP152G1N
MLCP153G1N
MLCP172G1N
MLCP173G1N

MLCH502J5N
MLCH503J5N
MLCH702J5N
MLCH703J5N
MLCH102J5N
MLCH103J5N
MLCP152J5N
MLCP153J5N
MLCP172J5N
MLCP173J5N

Lighting: Enclosed and Gasketed — Area — HID

50

Lighting

Shown with Globe and Optional Guard

PSMH

Pendant Cone ­— One Hub, Rigid Mounting
PSMH

50

PSMH

70

PSMH

100

PSMH

150

PSMH
Shown with Refractor
Ceiling ­— Five Hubs, Four Close-up Plugs

175

PSMH

50

PSMH

70

PSMH

100

PSMH

150

PSMH

175

Shown with Globe

➊ For Flexible Pendant Mount, change A to F in catalog number (except 50 W HPS).
➋ To order fixture with NEMA Type I or NEMA Type III refractor, change final digit 5 in catalog number to 1 or 3.
➌ For fixtures with guards, substitute a G for the N before adding voltage suffix. See following pages for accessory ordering information.
➍ Add the following voltage and frequency designation before Z2 suffix:
Voltage Suffixes
Lamp Type Lamp Watts
LB
MT
5MT
48
125
225
226
235
245
C2 V
C3 V
C6 V
C7 V
TT V
Inc.
150 Max.
X
—
—
—
—
—
—
—
—
—
—
—
—
—
HPS
50
—
X
—
—
—
X
X
—
X
—
—
—
—
X
HPS
70
—
X
—
X
X
X
X
—
X
—
—
—
—
X
HPS
100
—
X
—
X
X
X
X
—
X
—
—
—
—
X
HPS
150
—
X
—
X
X
X
X
—
X
X
X
X
X
X
PSMH
50
—
X
—
X
—
—
—
—
—
—
—
—
—
X
PSMH
70
—
X
—
X
X
X
—
—
X
—
—
—
—
X
PSMH
100
—
X
—
X
X
X
—
—
X
—
—
—
—
X
PSMH
150
—
X
—
X
—
—
—
—
X
—
—
—
—
X
PSMH
175
—
X
X
X
—
—
—
—
X
—
—
—
—
X
175
—
X
—
—
—
—
—
—
—
X
X
X
X
X
MH V
Voltages:
LB - Incandescent, 120 V 60 Hz
125 - 120 V 50 Hz
245 - 240 V 50 Hz
MT - 120/208/240/277 V 60 Hz
225 - 225 V 50 Hz
C2 - 208 V 60 Hz, CWI V
226 - 220 V 60 Hz
C3 - 240 V 60 Hz, CWI V
C7 - 600 V 60 Hz, CWI V,
5MT - 120/208/240/277/480 V 60 Hz
48 - 480 V 60 Hz
235 - 230 V 50 Hz
C6 - 480 V 60 Hz, CWI V
TT - 120/277/347 V 60 Hz, CWA V
➎ Add Z2 suffix for factory sealed non-sparking/restricted breathing protection (AEx nA nR). Add ZB suffix for restricted breathing protection (AEx nR).
➏ Add Z for factory sealed restricted breathing protection (Ex nR) V.
➐ For 150 W HPS fixtures, use S-55 lamp type only.
V CSA Certification Only.
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

929

Mercmaster™ III Low Profile Luminaires
50 W - 175 W PSMH

High Power Factor (min. P.F. 90%). Medium base lamps.
Class I, Division 2, Groups A, B, C, D
Class I, Zone 2, AEx nA nR IIC (Z2)
Class I, Zone 2, Ex nR IIC (Z) V
Class I, Zone 2, AEx nR IIC (ZB)

Class II, Division 1 and 2, Groups E, F, G
Class III
Simultaneous Exposure (Class I, Division 2/
Class II, Division 1)

Lamp Type

Lamp Watts

Hub Size
(Inches)

Fixtures Outside Type (Salt Water)
Type 4X
IP66

Catalog Numbers ➌➍➎➏
With Globe
With Type V 8” Refractor ➋

Lighting: Enclosed and Gasketed — Area — HID

Lighting

Wall ­— Five Hubs, Four Close-Up Plugs

Shown with Refractor and Optional Guard

PSMH

50

PSMH

70

PSMH

100

PSMH

150

PSMH

175

PSMH

50

PSMH

70

PSMH

100

PSMH

150

PSMH

175

PSMH

50

PSMH

70

PSMH

100

PSMH

150

PSMH

175

3/4
1
3/4
1
3/4
1
3/4
1
3/4
1

MLWH502G1N
MLWH503G1N
MLWH702G1N
MLWH703G1N
MLWH102G1N
MLWH103G1N
MLWP152G1N
MLWP153G1N
MLWP172G1N
MLWP173G1N

MLWH502J5N
MLWH503J5N
MLWH702J5N
MLWH703J5N
MLWH102J5N
MLWH103J5N
MLWP152J5N
MLWP153J5N
MLWP172J5N
MLWP173J5N

1-1/4
1-1/2
1-1/4
1-1/2
1-1/4
1-1/2
1-1/4
1-1/2
1-1/4
1-1/2

MLSH504G1N
MLSH505G1N
MLSH704G1N
MLSH705G1N
MLSH104G1N
MLSH105G1N
MLSP154G1N
MLSP155G1N
MLSP174G1N
MLSP175G1N

MLSH504J5N
MLSH505J5N
MLSH704J5N
MLSH705J5N
MLSH104J5N
MLSH105J5N
MLSP154J5N
MLSP155J5N
MLSP174J5N
MLSP175J5N

1-1/4
1-1/2
1-1/4
1-1/2
1-1/4
1-1/2
1-1/4
1-1/2
1-1/4
1-1/2

MLRH504G1N
MLRH505G1N
MLRH704G1N
MLRH705G1N
MLRH104G1N
MLRH105G1N
MLRP154G1N
MLRP155G1N
MLRP174G1N
MLRP175G1N

MLRH504J5N
MLRH505J5N
MLRH704J5N
MLRH705J5N
MLRH104J5N
MLRH105J5N
MLRP154J5N
MLRP155J5N
MLRP174J5N
MLRP175J5N

25° Stanchion —
­ One Hub

Shown with Globe and Optional Guard
90° Stanchion —
­ One Hub

Shown with Refractor and Optional Guard

➊ For Flexible Pendant Mount, change A to F in catalog number (except 50 W HPS).
➋ To order fixture with NEMA Type I or NEMA Type III refractor, change final digit 5 in catalog number to 1 or 3.
➌ For fixtures with guards, substitute a G for the N before adding voltage suffix. See following pages for accessory ordering information.
➍ Add the following voltage and frequency designation before Z2 suffix:
Voltage Suffixes
Lamp Type Lamp Watts
LB
MT
5MT
48
125
225
226
235
245
C2 V
C3 V
C6 V
C7 V
TT V
Inc.
150 Max.
X
—
—
—
—
—
—
—
—
—
—
—
—
—
HPS
50
—
X
—
—
—
X
X
—
X
—
—
—
—
X
HPS
70
—
X
—
X
X
X
X
—
X
—
—
—
—
X
HPS
100
—
X
—
X
X
X
X
—
X
—
—
—
—
X
HPS
150
—
X
—
X
X
X
X
—
X
X
X
X
X
X
PSMH
50
—
X
—
X
—
—
—
—
—
—
—
—
—
X
PSMH
70
—
X
—
X
X
X
—
—
X
—
—
—
—
X
PSMH
100
—
X
—
X
X
X
—
—
X
—
—
—
—
X
PSMH
150
—
X
—
X
—
—
—
—
X
—
—
—
—
X
PSMH
175
—
X
X
X
—
—
—
—
X
—
—
—
—
X
175
—
X
—
—
—
—
—
—
—
X
X
X
X
X
MH V
Voltages:
LB - Incandescent, 120 V 60 Hz
125 - 120 V 50 Hz
245 - 240 V 50 Hz
MT - 120/208/240/277 V 60 Hz
225 - 225 V 50 Hz
C2 - 208 V 60 Hz, CWI V
226 - 220 V 60 Hz
C3 - 240 V 60 Hz, CWI V
C7 - 600 V 60 Hz, CWI V,
5MT - 120/208/240/277/480 V 60 Hz
48 - 480 V 60 Hz
235 - 230 V 50 Hz
C6 - 480 V 60 Hz, CWI V
TT - 120/277/347 V 60 Hz, CWA V
➎ Add Z2 suffix for factory sealed non-sparking/restricted breathing protection (AEx nA nR). Add ZB suffix for restricted breathing protection (AEx nR).
➏ Add Z for factory sealed restricted breathing protection (Ex nR) V.
➐ For 150 W HPS fixtures, use S-55 lamp type only.
V CSA Certification Only.

930

Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

Mercmaster™ III Low Profile Luminaire Mounting Hoods
High Pressure Sodium and Pulse Start Metal Halide

Listed for simultaneous exposure to combustible dusts and flammable gases or vapors.

Mounting Hoods
Description

Hub Size (Inches)

Catalog Number

One Hub, Rigid Mounting

3/4

KPA-75

1

KPA-100

3/4

KPAF-75

1

KPAF-100

3/4

KPCH-75

1

KPCH-100

Lighting

Pendant

Pendant — Flexible
One Hub, Flexible Mounting

One Hub, Rigid or Flexible Mounting
Ceiling
Five Hubs, Four Close-Up Plugs

3/4

KPC-75

1

KPC-100

3/4

KPWB-75

1

KPWB-100

Wall
Five Hubs, Four Close-Up Plugs
25° Stanchion
One Hub

1-1/4

KPS-125

1-1/2

KPS-150

1-1/4

KPST-125

1-1/2

KPST-150

90° Stanchion
One Hub

Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

931

Lighting: Enclosed and Gasketed — Area — HID

Pendant Cone

Mercmaster™ III Low Profile Luminaire Ballast Bodies
High Pressure Sodium and Pulse Start Metal Halide

Listed for simultaneous exposure to combustible dusts and flammable gases or vapors.

Lighting

Ballast Bodies

Ballast Body for Glass Refractor

Ballast Body for Glass Globe or Polymeric Refractor

Lighting: Enclosed and Gasketed — Area — HID

High Pressure Sodium 	
High Power Factor (Min. P.F. 90%)
Lamp
Type
Inc.

Lamp
Watts

Pulse Start Metal Halide 	
Super Constant Wattage Autotransformer (Min. P.F. 90%)

Catalog Number ➍➎
For Globe

150 Max. MLBG15I

For Refractor

Voltage Suffixes
LB

MT

5MT

48

125

225

226

235

245 C2 V C3 V C6 V C7 V TT V

MLBR15I

X

—

—

—

—

—

—

—

—

—

—

—

—

—

HPS

50

MLBG50L ➊➋

MLBR50L ➊➋

—

X

—

—

—

X

X

—

X

—

—

—

—

X

HPS

70

MLBG70L ➊➋

MLBR70L ➊➋

—

X

—

X

X

X

X

—

X

—

—

—

—

X

HPS

100

MLBG10L ➊➋

MLBR10L ➊➋

—

X

—

X

X

X

X

—

X

—

—

—

—

X

HPS

150

MLBG15L ➊➋

MLBR15L ➊➋

—

X

—

X

X

X

X

—

X

X

X

X

X

X

PSMH

50

MLBG50H ➋➌ MLBR50H ➋➌

—

X

—

X

—

—

—

—

—

—

—

—

—

X

PSMH

70

MLBG70H ➋➌ MLBR70H ➋➌

—

X

—

X

X

X

—

—

X

—

—

—

—

X

PSMH

100

MLBG10H ➋➌ MLBR10H ➋➌

—

X

—

X

X

X

—

—

X

—

—

—

—

X

PSMH

150

MLBG15P ➋➌ MLBR15P ➋➌

—

X

—

X

—

—

—

—

X

—

—

—

—

X

PSMH

175

MLBG17P ➋➌ MLBR17P ➋➌

—

X

X

X

—

—

—

—

X

—

—

—

—

X

MH V

175

MLBG17H ➋

—

X

—

—

—

—

—

—

—

X

X

X

X

X

Voltages:
LB - Incandescent, 120 V 60 Hz
MT - 120/208/240/277 V 60 Hz
5MT - 120/208/240/277/480 V 60 Hz
48 - 480 V 60 Hz
125 - 120 V 50 Hz
225 - 225 V 50 Hz
226 - 220 V 60 Hz

MLBR17H ➋

235 - 230 V 50 Hz
245 - 240 V 50 Hz
C2 - 208 V 60 Hz, CWI V
C3 - 240 V 60 Hz, CWI V
C6 - 480 V 60 Hz, CWI V  
C7 - 600 V 60 Hz, CWI V,
TT - 120/277/347 V 60 Hz, CWA V

➊ After voltage suffix add: -S for Smart Starter, -SR for Smart Hot Restrike, -R for ballast body with Hot Restrike Ignitor.
➋ Add -E after voltage suffix for ballast body with provision for Quartz Emergency Light. Not suitable for hazardous locations.
➌ After voltage suffix add: -S for Smart Starter.
➍ Add Z2 suffix for factory sealed non-sparking/restricted breathing protection (AEx nA nR). Add ZB suffix for restricted breathing protection (AEx nR).
➎ Add Z for factory sealed restricted breathing protection (Ex nR) V.
V CSA Certification Only.

932

Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

Mercmaster™ III Low Profile Luminaire Accessories and Replacement Parts
High Pressure Sodium and Pulse Start Metal Halide

Listed for simultaneous exposure to combustible dusts and flammable gases or vapors.

Description

Catalog Number

Prismatic Glass Globes ­— Heat-Resistant
VPGL-1HR
VPGL-1AM

Blue

VPGL-1BL

Green

VPGL-1GR

Red

VPGL-1RE

IES/NEMA Distribution Curves

Catalog Number

Glass Globe
Light Distribution
Closed Prismatic Glass Refractors — All Heat-Resistant

LPG-R1

NEMA Type III

LPG-R3

NEMA Type V

LPG-R5

Closed Prismatic Polymeric Refractors — For Use with PSMH Lamps
100 W max. 104 °F/40 °C max. ambient temperature. Suitable for Class II, Division 1 and 2, Groups F, G;
NEMA 4X, UL 1598A Marine Type Electric Fixtures Outside Type (Salt Water)

Polymeric Refractor

NEMA Type II

LPRF-2CP

NEMA Type III

LPRF-3CP

NEMA Type IV

LPRF-4CP

NEMA Type V

LPRF-5CP
Description

Catalog Number

White Polyester Reflectors — Furnished with stainless steel screws
For Globe Fixtures

For Glass Refractor Fixtures
Standard Dome
Guards

30° Angle

Standard Dome

KR2-ST

Deep Dome

KR2-DD ➊

30° Angle

KR2-AN

Standard Dome

CMR-4ST ➋

Deep Dome

CMR-4DD ➊

30° Angle

CMR-4AN

Globe Guard       
Refractor Guard   

KGU1
KRG2

Globe Gasket
Refractor Gasket

VPGL-GK
KRF-GK

Globe Guard
Refractor Guard
Replacement Globe Gaskets — Silicone Rubber

Globe Gaskets
➊ Dark Skies Compliant.
➋ Standard and deep dome reflectors may interfere with bottom conduit entry if used with KPST and KPWB mounting hoods.
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

933

Lighting: Enclosed and Gasketed — Area — HID

Glass Refractor

NEMA Type I

Lighting

Clear
Amber

Mercmaster™ III Low Profile Luminaire Electrical Specifications and Fuse Kits
High Pressure Sodium and Pulse Start Metal Halide

Listed for simultaneous exposure to combustible dusts and flammable gases or vapors.

Lighting: Enclosed and Gasketed — Area — HID

Lighting

Class I, Division 2, Groups A, B, C, D
Class I, Zone 2, AEx nA nR IIC (Z2)
Class I, Zone 2, Ex nR IIC (Z) V
Class I, Zone 2, AEx nR IIC (ZB)

Electrical Specifications
Line
Type of
Starting
Voltage
Ballast ➊
Amps
50 Watt High Pressure Sodium
120
HX-HPF
0.58
208
HX-HPF
0.35
240
HX-HPF
0.31
277
HX-HPF
0.25
HX-HPF
0.26
347 V
70 Watt High Pressure Sodium
120
HX-HPF
0.90
208
HX-HPF
0.50
240
HX-HPF
0.44
277
HX-HPF
0.35
HX-HPF
0.30
347 V
480
HX-HPF
0.21
100 Watt High Pressure Sodium
120
HX-HPF
1.30
208
HX-HPF
0.76
240
HX-HPF
0.66
277
HX-HPF
0.60
HX-HPF
0.45
347 V
480
HX-HPF
0.33
480
C.W.I.
0.17
600
C.W.I.
0.14
150 Watt High Pressure Sodium ➋
120
HX-HPF
2.00
208
HX-HPF
1.15
240
HX-HPF
1.00
277
HX-HPF
0.85
HX-HPF
0.52
347 V
480
HX-HPF
0.50
480
C.W.I.
0.25
600
C.W.I.
0.19
50 Watt Pulse Start Metal Halide
120
HX-HPF
0.87
208
HX-HPF
0.51
240
HX-HPF
0.47
277
HX-HPF
0.32
HX-HPF
0.15
347 V
70 Watt Pulse Start Metal Halide
120
HX-HPF
0.80
208
HX-HPF
0.50
240
HX-HPF
0.43
277
HX-HPF
0.39
HX-HPF
0.20
347 V
480
HX-HPF
0.26
100 Watt Pulse Start Metal Halide
120
HX-HPF
1.20
208
HX-HPF
0.70
240
HX-HPF
0.61
277
HX-HPF
0.55
HX-HPF
0.40
347 V
480
HX-HPF
0.30

Class II, Division 1 and 2, Groups E, F, G
Class III
Simultaneous Exposure (Class I, Division 2/
Class II, Division 1)

Fixtures Outside Type (Salt Water)
Type 4X
IP66

Electrical Specifications
Line
Type of
Starting
Voltage
Ballast ➊
Amps
150 Watt Pulse Start Metal Halide
120
HX-HPF
1.75
208
HX-HPF
1.30
240
HX-HPF
0.85
277
HX-HPF
0.77
Super C.W.A.
0.65
347 V
480
Super C.W.A.
0.45
175 Watt Pulse Start Metal Halide
120
Super C.W.A.
0.90
208
Super C.W.A.
0.50
240
Super C.W.A.
0.35
277
Super C.W.A.
0.30
Super C.W.A.
0.25
347 V
480
Super C.W.A.
0.25
175 Watt Metal Halide V
120
C.W.A.
1.30
208
C.W.A.
0.75
240
C.W.A.
0.65
277
C.W.A.
0.55
347
C.W.A.
0.50
480
C.W.I.
0.20
600
C.W.I.
0.16
Fuse Kit for Field Installation

Operating
Amps

Total
Watts

0.58
0.33
0.29
0.25
0.21

64
64
64
64
68

0.82
0.48
0.41
0.36
0.30
0.21

94
94
94
94
94
94

1.15
0.67
0.60
0.52
0.39
0.31
0.30
0.24

130
130
130
130
130
135
130
130

1.70
0.95
0.85
0.72
0.56
0.47
0.42
0.35

188
188
188
188
188
189
190
190

Lamp
Watts

0.62
0.40
0.35
0.32
0.20

67
67
67
67
67

70W

0.85
0.52
0.44
0.39
0.28
0.23

95
95
95
95
88
95

1.15
0.70
0.58
0.50
0.40
0.35

130
130
130
130
129
140

50W

100W

150W

175W

Volts
120
208
240
277
347 V
120
208
240
277
347 V
480
120
208
240
277
347 V
480
120
208
240
277
347 V
480
120
208
240
277
347 V
480

Fuse Quantity
Required
1
2
2
1
1
1
2
2
1
1
2
1
2
2
1
1
2
1
2
2
1
1
2
1
2
2
1
1
2

Operating
Amps

Total
Watts

1.60
1.00
0.80
0.70
0.55
0.42

188
188
188
188
185
185

1.78
1.08
0.89
0.76
0.65
0.50

199
199
199
199
208
213

1.80
1.04
0.90
0.80
0.65
0.45
0.37

210
210
210
210
210
215
215

Fuse Kit Catalog Number
HPS
PSMH
F5
F3
F3
F3
F3
F2
F2
F2
F1
F1
F5
F4
F3
F3
F3
F3
F2
F2
F1
F2
F2
F1
F8
F6
F5
F4
F5
F3
F3
F3
F1
F2
F3
F2
F10
F10
F5
F5
F5
F5
F5
F4
F2
F2
F3
F3
—
F5
—
F3
—
F3
—
F2
F2
F2
—
F2

➊ C.W.A. – Constant Wattage Autotransformer. HX-HPF – High Reactance High Power Factor Autotransformer. Super C.W.A. – Super Constant Wattage Autotransformer.
➋ 150 W HPS units equipped with ballasts to operate 55 V lamps only.
V CSA Certification Only.

934

Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

Mercmaster™ III Low Profile Luminaire Dimensions and Weights
High Pressure Sodium and Pulse Start Metal Halide

Listed for simultaneous exposure to combustible dusts and flammable gases or vapors.

Pendant (Rigid or Flex)
12.06”/306.0 mm

Pendant Cone

1.17”/
30.0 mm

Ceiling

12.06”/306.0 mm

25º Stanchion

13.62”/346.0 mm

1.75”/
45.0 mm

12.06”/306.0 mm

2.00”/
51.0 mm

15.28”/
388.0 mm

Lighting

5.59”/
142.0 mm

9.25”/
235.0 mm
12.05”/
306.0 mm

Wall Mount
17.01”/
432.0 mm
10.94”/
278.0 mm

90º Stanchion
3.38”/
85.8 mm

17.23”/438.0 mm
(4) Mounting Holes
0.31”/8.0 mm

7.60”/
193.0 mm

9.79”/249.0 mm

12.05”/
306.0 mm

12.06”/306.0 mm

Globe or Polymeric Refractor Ballast
Housing

8" Glass Refractor Ballast Housing

Standard Polyester Reflector

30º Angle Polyester Reflector

Globe, Guard and Refractors

Refractor Body, Refractor and Guard

Polymeric Refractor

Deep Dome

Mercmaster III Low Profile Ballast and Accessory Weights ➊
Globe Housing Ballast (Wt. Lbs/Kg) Refractor Housing Ballast (Wt. Lbs/Kg)
Watts

HPS

PSMH

HPS

PSMH

Mounting
Hoods

Wt.
Lbs/Kg

Refractors, Globes,
Guards and Reflectors

Wt.
Lbs/Kg

50

7.25/3.3

7.00/3.2

7.75/3.5

7.50/3.4

Pendant

2.25/1.0

8” Glass Refractor

5.25/2.4

70

8.25/3.7

7.75/3.5

8.75/4.0

8.25/3.7

Pendant Cone

2.50/1.1

Glass Globe

3.75/1.7

100

9.75/4.4

9.25/4.2

10.25/4.6

9.75/4.4

Ceiling

3.00/1.4

Refractor Guard

1.00/0.5

150

10.75/4.9

10.75/4.9

11.25/5.1

11.25/5.1

Wall

4.00/1.8

Globe Guard

1.00/0.5

175

—

11.00/5.0

—

11.50/5.2

25° Stanchion

3.25/1.5

Standard Dome

2.50/1.1

90° Stanchion

3.75/1.7

Deep Dome

5.00/2.3

30° Angle

2.50/1.1

Polymeric Refractor

2.43/1.1

➊ Weights are approximate. Add 0.25 lbs/0.1 kg for Quartz option.
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

935

Lighting: Enclosed and Gasketed — Area — HID

4.06”/
103.0 mm

PCD2 Series Factory Sealed Hazardous Location Photocontrol
For use in Class I, Division 2, Groups A, B, C, D locations

Maintains Class I, Division 2 rating for Mercmaster III – Low Profile, Mercmaster III, and Mercmaster III – 400 Series Luminaires, Mercmaster LED
Class I, Division 2, Groups A, B, C, D
NEMA 4X

Lighting

Applications

Materials

•	 Encapsulated photocontrol provides automatic dusk-to-dawn
lighting control in Class I, Division 2 locations.
•	 Typical applications include walkways, security areas and any
other outdoor lighting application.
•	 For use with Mercmaster III – Low Profile, Mercmaster III, and
Mercmaster III – 400 Series Luminaires.
•	 For remote mounting in FS Boxes.

•	 Encapsulated with epoxy sealing compound
•	 FS: aluminum

Certifications and Compliances
•	 UL Standard: 1604 ­– Hazardous (Classified) Locations
•	 cULus Recognized

Lighting: Enclosed and Gasketed — Area — HID

Features
•	 Factory sealed design eliminates the need for an explosionproof
enclosure.
•	 Can be easily installed in the field.
•	 Solid state design for performance and reliability.
•	 Available for 120, 208, 240, or 277 volts.
•	 50-400 W HID, incandescent or fluorescent, 50/60 Hz.
•	 1000 V.A. Voltage/Ampere
•	 Minimum time delay: 15 seconds to eliminate nuisiance tripping.
•	 Provided with (3) 18AWG stranded leads 6”/152.4mm in length.
•	 Will fit through standard 1/2” knockout.

Factory-Installed Photocontrol

Dimensions

Add to fixture catalog after voltage; i.e.: KPWBL1075MTH1.

Mercmaster III wall mounting hood
with photocontrol installed shown

Voltage Range

Suffix Designation

120 V, 50/60 Hz

H1

208 V, 50/60 Hz

H2

240 V, 50/60 Hz

H3

277 V, 50/60 Hz

H4
1.13”
28.7
mm
1.13”
28.7 mm

Photocontrol in FS Cover for Use with FS/FD Box

Supplied with two stainless steel screws. For neoprene gasket, order catalog number FS-GKR-1N.

Voltage Range

Catalog Number

120V, 50/60 Hz

FSKA-PC120D2

208-277V, 50/60 Hz

FSKA-PC247D2

1.375”
34.9
mm
1.375”
34.9 mm
2.56”
65.0
mm
2.56”
65.0 mm

1.13”
28.7 mm

Photocontrol for Field Installation
Max. Current

Catalog Number

120 V, 50/60 Hz

Voltage Range

8.3 Amp

PC120D2

208-277 V, 50/60 Hz

3.5 Amp

34.9 mm
PC247D2

2.56”
65.0 mm

936

1.375”

0.69”
17.5 mm
1.19”
30.2 mm

1.94”
49.2 mm

Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

Mercmaster™ III Low Profile Luminaire Photometric Data
150 W HPS

Listed for simultaneous exposure to combustible dusts and flammable gases or vapors.
* Photometric data is based on a fixture with
a 150-watt clear High Pressure Sodium lamp
(16,000 lumen).

Zone

Lumens

For candlepower values of fixtures with other
HPS lamps, use the following multipliers: for
a 100 W (9,500 lumen) HPS lamp – 0.594; for a
70 W (6,400 lumen) HPS lamp – 0.40; for a 50 W
(4,000 lumen) HPS lamp – 0.25. For candlepower
values of fixture with guard, multiply by – 0.95.

Total Luminaire Efficiency = 83%

REPORT NUMBER: ML15LG
Lamps: 150 W High Pressure Sodium with Globe only *

CIE Type – Semi-Direct

28.58

10-20

123.97

20-30

304.16

30-40

513.64

0-180

3.9

Coefficients of Utilization – Zonal Cavity Method

40-50

889.19

90-270

3.9

Effective Floor Cavity Reflectance 0.20

50-60

1299.53

Diagonal

3.7

60-70

1506.73

70-80

1706.16

80-90

1800.53

Lumens % Lamp % Fixture

1 77 71 66 61 72 66 61 57 57 53 49 48 45 42 40 37 35 31

90-100

1791.58

0-30

4563.72

2.9

3.4

2 68 59 51 45 63 55 48 42 46 41 36 39 34 31 32 28 25 21

100-110

1652.69

0-40

970.35

6.1

7.3

3 61 50 42 35 56 46 39 33 39 33 28 32 27 23 26 22 19 16

110-120

1311.22

0-60

3159.07

19.7

23.8

4 55 43 35 28 50 40 32 26 34 27 22 28 23 18 22 18 15 12

120-130

351.25

0-90

8172.49

51.1

61.5

5 50 38 29 23 46 35 27 21 29 23 18 24 19 15 19 15 12

9

130-140

5.14

90-120

4755.49

29.7

35.8

6 46 33 25 19 42 31 23 18 26 20 15 21 16 12 17 13 10

7

140-150

0.00

90-130

5106.74

31.9

38.4

7 42 30 22 16 38 27 20 15 23 17 13 19 14 10 15 11

8

6

150-160

0.00

90-150

5111.87

31.9

38.4

8 39 27 19 14 36 25 18 13 21 15 11 17 12

9 14 10

7

5

160-170

0.00

90-180

5111.87

31.9

38.5

9 36 24 17 12 33 22 16 11 19 13

9 16 11

8 13

9

6

4

170-180

0.00

0-180

13284.37

83.0

100.0

10 33 22 15 11 31 20 14 10 17 12

8 15 10

7 12

8

5

4

Lumens

% Ceiling Rcc

80

70

50

30

10

0

% Walls Rw 70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0
Zonal Lumen Summary
Zone

0 91 91 91 91 85 85 85 85 75 75 75 65 65 65 55 55 55 51

Total Luminaire Efficiency = 73.2%

REPORT NUMBER: ML15LST
Lamps: 150 W High Pressure Sodium with
Standard Dome Reflector *

CIE Type – Direct

0-10

219.96

10-20

683.41

20-30

1267.92

30-40

1613.68

0-180

1.64

Coefficients of Utilization – Zonal Cavity Method

40-50

1967.79

90-270

1.64

Effective Floor Cavity Reflectance 0.20

50-60

2333.86

Diagonal

1.88

60-70

2328.33

70-80

1118.52

80-90

174.91

Spacing
Criteria

Plane

% Ceiling Rcc

80

70

50

30

10

0

% Walls Rw 70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0
Zonal Lumen Summary
Zone

0 87 87 87 87 85 85 85 85 81 81 81 78 78 78 75 75 75 73

Lumens % Lamp % Fixture

1 79 75 71 68 77 73 70 67 70 67 65 67 65 63 64 62 61 59

90-100

1.23

0-30

2171.29

13.6

18.5

2 70 63 58 53 68 62 57 52 59 55 51 57 53 50 55 52 49 47

100-110

0.00

0-40

3784.97

23.7

32.3

3 63 54 48 42 61 53 47 42 51 46 41 49 44 40 47 43 40 38

110-120

0.00

0-60

8086.62

50.5

69.1

4 57 47 40 35 55 46 39 34 44 38 34 42 37 33 41 36 33 31

120-130

0.00

0-90

11708.37

73.2

100.0

5 52 41 34 29 50 41 34 29 39 33 28 37 32 28 36 31 28 26

130-140

0.00

90-120

1.23

0.0

0.0

6 48 37 30 24 46 36 29 24 35 29 24 33 28 24 32 27 24 22

140-150

0.00

90-130

1.23

0.0

0.0

7 44 33 26 21 42 32 26 21 31 25 21 30 25 21 29 24 20 19

150-160

0.00

90-150

1.23

0.0

0.0

8 41 30 23 18 39 29 23 18 28 22 18 27 22 18 26 22 18 16

160-170

0.00

90-180

1.23

0.0

0.0

9 38 27 21 16 37 27 20 16 26 20 16 25 20 16 24 19 16 14

170-180

0.00

0-180

11709.6

73.2

100.0

10 35 25 19 15 34 24 18 14 24 18 14 23 18 14 22 18 14 13

Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

937

Lighting: Enclosed and Gasketed — Area — HID

Zone

Spacing
Criteria

Plane

Lighting

0-10

Mercmaster™ III Low Profile Luminaire Photometric Data
150 W HPS

Listed for simultaneous exposure to combustible dusts and flammable gases or vapors.
* Photometric data is based on a fixture with
a 150-watt clear High Pressure Sodium lamp
(16,000 lumen).

Lighting: Enclosed and Gasketed — Area — HID

Lighting

Zone

Lumens

For candlepower values of fixtures with other
HPS lamps, use the following multipliers: for
a 100 W (9,500 lumen) HPS lamp – 0.594; for a
70 W (6,400 lumen) HPS lamp – 0.40; for a 50 W
(4,000 lumen) HPS lamp – 0.25. For candlepower
values of fixture with guard, multiply by – 0.95.

Total Luminaire Efficiency = 68.4%

REPORT NUMBER: ML15LAN
Lamps: 150 W High Pressure Sodium with
30° Angle Dome Reflector *

CIE Type – Direct

0-10

168.01

10-20

536.92

20-30

972.38

30-40

1342.99

0-180

2.3

40-50

1625.08

90-270

2.0

50-60

1721.88

Diagonal

1.8

60-70

1586.98

70-80

1369.71

80-90

995.76

Lumens % Lamp % Fixture

1 70 66 62 58 68 64 60 57 60 57 54 57 54 52 54 52 50 48

90-100

461.94

0-30

1677.30

10.5

15.3

2 63 56 50 45 60 54 49 44 51 46 42 48 44 41 45 42 39 37

100-110

127.24

0-40

3020.29

18.9

27.6

3 56 48 41 36 54 46 40 35 44 38 34 41 37 33 39 35 32 30

110-120

27.54

0-60

6367.25

39.8

58.2

4 51 42 35 29 49 40 34 29 38 32 28 36 31 27 34 30 26 24

120-130

4.31

0-90

10319.70

64.5

94.3

5 47 37 30 24 45 36 29 24 34 28 23 32 27 23 30 26 22 20

130-140

2.68

90-120

616.71

3.9

5.6

6 43 33 26 21 41 32 25 20 30 24 20 28 23 19 27 22 19 17

140-150

0.00

90-130

621.02

3.9

5.7

7 39 29 23 18 38 28 22 18 27 21 17 26 21 17 24 20 16 15

150-160

0.00

90-150

623.70

3.9

5.7

8 37 26 20 16 35 26 20 15 24 19 15 23 18 15 22 18 14 13

160-170

0.00

90-180

623.70

3.9

5.7

9 34 24 18 14 33 23 18 14 22 17 13 21 17 13 20 16 13 11

170-180

0.00

0-180

10943.41

68.4

100.0

10 32 22 16 12 31 22 16 12 21 15 12 20 15 12 19 15 11 10

Zone

Lumens

Spacing
Criteria

Plane

Coefficients of Utilization – Zonal Cavity Method
Effective Floor Cavity Reflectance 0.20
% Ceiling Rcc

80

70

50

30

10

0

% Walls Rw 70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0
Zonal Lumen Summary
Zone

0 80 80 80 80 78 78 78 78 74 74 74 70 70 70 66 66 66 64

Total Luminaire Efficiency = 77.6%

REPORT NUMBER: ML15LJ5
Lamps: 150 W High Pressure Sodium with
8” Prismatic Glass Refracter – NEMA Type V *

CIE Type – Semi-Direct

0-10

16.51

10-20

135.03

20-30

274.24

30-40

463.44

0-180

2.22

40-50

1125.38

90-270

2.20

50-60

1688.89

Diagonal

3.50

60-70

3137.76

70-80

2421.27

80-90

1145.98

90-100

411.16

0-30

425.77

2.7

3.4

2 66 56 49 42 62 54 47 41 49 43 38 44 39 35 40 36 32 29

100-110

632.32

0-40

889.22

5.6

7.2

3 58 46 38 31 54 44 36 30 40 33 27 36 30 25 32 27 23 21

110-120

448.30

0-60

3703.50

23.1

29.8

4 51 39 30 23 48 37 29 22 33 26 21 30 24 19 27 22 17 15

120-130

293.08

0-90

10408.50

65.1

83.8

5 46 34 25 18 43 32 24 18 29 22 16 26 20 15 23 18 13 11

130-140

154.61

90-120

1491.78

9.3

12.0

6 42 29 21 15 40 28 20 14 25 18 13 22 16 12 20 15 11

8

140-150

59.30

90-130

1784.86

11.2

14.4

7 39 26 18 12 36 25 17 12 22 15 11 20 14 10 18 13

9

7

150-160

9.99

90-150

1998.77

12.5

14.4

8 36 23 15 10 33 22 15 10 20 13

9 18 12

8 16 11

7

5

160-170

0.49

90-180

2009.26

12.6

16.2

9 33 21 14

9 31 20 13

8 18 12

8 16 11

7 15 10

6

4

170-180

0.00

0-180

12417.76

77.6

100.0

10 31 19 12

8 29 18 12

7 17 11

7 15 10

6 13

5

4

938

Spacing
Criteria

Plane

Coefficients of Utilization – Zonal Cavity Method
Effective Floor Cavity Reflectance 0.20
% Ceiling Rcc

80

70

50

30

10

0

% Walls Rw 70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0
Zonal Lumen Summary
Zone

0 89 89 89 89 86 86 86 86 79 79 79 73 73 73 68 68 68 65

Lumens % Lamp % Fixture

1 76 70 65 60 72 67 62 58 61 57 54 56 53 50 51 48 46 43

9

Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

Mercmaster™ III Low Profile Luminaire Photometric Data
100 W PSMH

Listed for simultaneous exposure to combustible dusts and flammable gases or vapors.
* Photometric data is based on a fixture with
a 100-watt clear Pulse Start Metal Halide lamp
(8,500 lumen).

Zone

Lumens

For candlepower values of fixtures with other
PSMH lamps, use the following multipliers:
for a 50 W (3400 lumen) PSMH lamp – 0.40; for
a 70 W (5600 lumen) PSMH lamp – 0.66; for a
150 W (10,500 lumen) PSMH lamp – 1.24; for
a 175 W (17,500 lumen) PSMH lamp – 2.06.

For candlepower values of fixture with guard,
multiply by – 0.95.

Total Luminaire Efficiency = 85.7%

REPORT NUMBER: ML10HG
Lamps: 100 W Pulse Start Metal Halide with Globe only *

CIE Type – Semi-Direct

93.55

20-30

201.68

30-40

291.92

0-180

3.20

40-50

523.42

90-270

3.20

50-60

637.38

Diagonal

3.08

60-70

732.34

70-80

845.58

80-90

874.42

90-100

870.80

Spacing
Criteria

Plane

Coefficients of Utilization – Zonal Cavity Method
Effective Floor Cavity Reflectance 0.20
% Ceiling Rcc
% Walls Rw

Zonal Lumen Summary

70

50

30

10

0

70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0

0 95 95 95 95 89 89 89 89 78 78 78 68 68 68 58 58 58 54

Lumens % Lamp % Fixture

1 81 74 69 64 75 69 64 60 60 56 52 51 48 45 43 40 38 34

0-30

316.42

4.1

4.7

2 71 62 54 48 66 57 50 45 49 43 39 41 37 33 34 31 28 24

100-110 809.33

0-40

608.33

7.8

9.1

3 64 52 44 37 59 49 41 35 41 35 30 35 30 26 29 25 21 18

110-120 643.44

0-60

1769.13

22.7

26.5

4 57 45 37 30 53 42 34 28 36 29 24 30 25 20 25 20 17 14

120-130 139.00

0-90

4221.46

54.1

63.2

5 52 40 31 25 48 37 29 23 31 25 20 26 21 17 21 17 14 11

130-140

0.71

90-120 2323.56

29.8

34.8

6 48 35 27 21 44 33 25 19 28 21 17 23 18 14 19 15 11 9

140-150

0.00

90-130 2462.56

31.6

36.8

7 44 31 23 17 40 29 22 16 25 19 14 21 16 12 17 13 10 7

150-160

0.00

90-150 2463.27

31.6

36.8

8 41 28 20 15 37 26 19 14 22 16 12 19 14 10 16 11 8

6

160-170

0.00

90-180 2463.27

31.6

36.8

9 38 26 18 13 35 24 17 12 20 15 11 17 12 9 14 10 7

5

170-180

0.00

0-180

85.7

100.0

Zone

Zone

80

6684.73

Lumens

Total Luminaire Efficiency = 75.8%
CIE Type – Direct

10 35 23 16 12 32 22 15 11 19 13 9 16 11 8 13 9

6

5

REPORT NUMBER: ML10HST
Lamps: 100 W Pulse Start Metal Halide with
Standard Dome Reflector *

0-10

116.29

10-20

371.61

20-30

692.88

30-40

821.73

0-180

1.70

40-50

1064.03

90-270

1.70

50-60

1154.58

Diagonal

1.84

60-70

1134.19

70-80

470.22

80-90

83.66

Lumens % Lamp % Fixture

1 82 78 74 71 80 76 73 70 73 70 68 70 68 66 67 65 64 62

90-100

0.82

0-30

1180.78

15.1

20.0

2 73 66 61 56 71 65 60 55 62 58 54 60 56 53 57 54 51 50

100-110

0.00

0-40

2002.50

25.7

33.9

3 66 57 50 45 64 56 50 45 54 48 44 51 47 43 49 46 42 40

110-120

0.00

0-60

4221.11

54.1

71.4

4 60 50 43 37 58 49 42 37 47 41 36 45 40 36 43 39 35 33

120-130

0.00

0-90

5909.17

75.8

100.0

5 54 44 36 31 53 43 36 31 41 35 30 40 34 30 38 33 30 28

130-140

0.00

90-120

0.82

0.0

0.0

6 50 39 32 26 48 38 31 26 37 31 26 35 30 26 34 29 25 24

140-150

0.00

90-130

0.82

0.0

0.0

7 46 35 28 23 45 34 27 23 33 27 22 32 26 22 31 26 22 20

150-160

0.00

90-150

0.82

0.0

0.0

8 43 32 25 20 41 31 24 20 30 24 20 29 24 20 28 23 19 18

160-170

0.00

90-180

0.82

0.0

0.0

9 40 29 22 18 38 28 22 18 27 22 17 27 21 17 36 21 17 16

170-180

0.00

0-180

5910.00

75.8

100.0

10 37 26 20 16 36 26 20 16 25 20 16 24 19 16 24 19 15 14

Spacing
Criteria

Plane

Coefficients of Utilization – Zonal Cavity Method
Effective Floor Cavity Reflectance 0.20
% Ceiling Rcc
% Walls Rw

Zonal Lumen Summary
Zone

80

70

50

30

10

0

70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0

0 90 90 90 90 88 88 88 88 84 84 84 81 81 81 77 77 77 76

Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

939

Lighting: Enclosed and Gasketed — Area — HID

21.19

10-20

Lighting

0-10

Mercmaster™ III Low Profile Luminaire Photometric Data
100 W PSMH

Listed for simultaneous exposure to combustible dusts and flammable gases or vapors.
* Photometric data is based on a fixture with
a 100-watt clear Pulse Start Metal Halide lamp
(8,500 lumen).

Lighting: Enclosed and Gasketed — Area — HID

Lighting

Zone

Lumens

For candlepower values of fixtures with other
PSMH lamps, use the following multipliers:
for a 50 W (3400 lumen) PSMH lamp – 0.40; for
a 70 W (5600 lumen) PSMH lamp – 0.66; for a
150 W (10,500 lumen) PSMH lamp – 1.24; for
a 175 W (17,500 lumen) PSMH lamp – 2.06.

For candlepower values of fixture with guard,
multiply by – 0.95.

Total Luminaire Efficiency = 71.3%

REPORT NUMBER: ML10HAN
Lamps: 100 W Pulse Start Metal Halide with
30° Angle Dome Reflector *

CIE Type – Direct

0-10

91.83

10-20

301.65

20-30

543.23

30-40

703.02

0-180

2.08

40-50

877.11

90-270

2.06

50-60

850.33

Diagonal

1.76

60-70

7753.51

70-80

667.27

80-90

471.44

Lumens % Lamp % Fixture

1 74 69 65 62 71 67 64 60 63 60 58 60 57 55 57 55 53 51

90-100

200.90

0-30

936.72

12.0

16.8

2 66 59 53 48 64 57 51 47 54 49 45 51 47 43 48 45 42 40

100-110

62.89

0-40

1639.74

21.0

29.5

3 59 51 44 38 57 49 43 38 46 41 36 44 39 35 41 37 34 32

110-120

14.42

0-60

3367.18

43.2

60.6

4 54 44 37 31 52 43 36 31 40 35 30 38 33 29 36 32 28 27

120-130

1.07

0-90

5281.39

67.7

95.0

5 49 39 32 26 47 38 31 26 36 30 25 34 29 25 32 28 24 22

130-140

0.00

90-120

278.21

3.6

5.0

6 45 35 28 23 43 34 27 22 32 26 22 30 25 21 29 24 21 19

140-150

0.00

90-130

279.28

3.6

5.0

7 42 31 24 20 40 30 24 19 29 23 19 27 22 18 26 22 18 16

150-160

0.00

90-150

279.28

3.6

5.0

8 39 28 22 17 37 28 21 17 26 21 17 25 20 16 24 19 16 14

160-170

0.00

90-180

279.28

3.6

5.0

9 36 26 19 15 35 25 19 15 24 19 15 23 18 14 22 17 14 13

170-180

0.00

0-180

5560.68

71.3

100.0

10 34 24 18 14 32 23 17 13 22 17 13 21 16 13 20 16 13 11

Zone

Lumens

Spacing
Criteria

Plane

Coefficients of Utilization – Zonal Cavity Method
Effective Floor Cavity Reflectance 0.20
% Ceiling Rcc
% Walls Rw

Zonal Lumen Summary
Zone

80

70

50

30

10

0

70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0

0 84 84 84 84 82 82 82 82 77 77 77 73 73 73 69 69 69 68

Total Luminaire Efficiency = 76.6%

REPORT NUMBER: ML10HJ5
Lamps: 100 W Pulse Start Metal Halide with
8” Prismatic Glass Refracter – NEMA Type V *

CIE Type – Semi-Direct

0-10

9.17

10-20

75.43

20-30

154.76

30-40

266.34

0-180

2.06

Coefficients of Utilization – Zonal Cavity Method

40-50

632.54

90-270

2.20

Effective Floor Cavity Reflectance 0.20

50-60

1155.59

Diagonal

3.26

60-70

1665.76

70-80

693.73

80-90

449.28

Lumens % Lamp % Fixture

1 77 71 67 62 73 68 64 60 63 59 56 58 55 52 53 51 49 46

90-100

177.44

0-30

239.35

3.1

4.0

2 67 58 51 45 64 56 49 44 51 46 41 47 42 38 43 39 36 33

100-110 288.25

0-40

505.69

6.5

8.5

3 59 48 40 34 56 46 39 32 42 36 30 38 33 28 34 30 26 24

110-120 208.52

0-60

2293.81

29.4

38.4

4 52 41 32 26 49 39 31 25 35 28 23 32 26 21 29 24 20 18

120-130 128.19

0-90

5102.58

65.4

85.4

5 47 35 26 20 44 33 25 19 30 23 18 27 21 17 25 20 15 13

130-140

56.80

90-120

674.20

8.6

11.3

6 43 30 22 16 40 29 21 15 26 19 14 24 18 13 21 16 12 10

140-150

14.94

90-130

802.38

10.3

13.4

7 39 27 19 13 37 25 18 13 23 16 12 21 15 11 19 14 10

8

150-160

0.10

90-150

874.12

11.2

13.4

8 36 24 16 11 34 23 15 10 21 14 10 19 13

9 17 12

8

6

160-170

0.00

90-180

874.22

11.2

14.6

9 33 21 14

9 31 20 14

9 19 12

8 17 11

8 15 10

7

5

170-180

0.00

0-180

5976.80

76.6

100.0

10 31 19 12

8 29 19 12

8 17 11

7 15 10

6 14

6

4

940

Spacing
Criteria

Plane

% Ceiling Rcc
% Walls Rw

Zonal Lumen Summary
Zone

80

70

50

30

10

0

70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0

0 89 89 89 89 85 85 85 85 79 79 79 73 73 73 68 68 68 65

9

Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

Mercmaster™ III HID 50-250 Watt Luminaires
High Pressure Sodium and Pulse Start Metal Halide

Listed for simultaneous exposure to combustible dusts and flammable gases or vapors.
Class I, Division 2, Groups A, B, C, D
Class I, Zone 2, AEx nA nR IIC (Z2)
Class I, Zone 2, Ex nR IIC (Z) V
Class I, Zone 2, AEx nR IIC (ZB)

Class II, Division 1 and 2, Groups E, F, G
Class III
Simultaneous Exposure (Class I, Division 2/
Class II, Division 1)

Fixtures Outside Type (Salt Water)
Type 4X
IP66

Applications

Lighting

Pendant Mount Fixture
with Prismatic Glass Refractor

Straight Stanchion-Mount Fixture
with Prismatic Glass Refractor and
Guard

Features
•	 Modular design allows scores of fixture component
combinations to meet installation and lighting needs. Many
most-used combinations are offered prewired and assembled,
complete with lamp, packaged in a single carton and ready to
install.
•	 Mogul lamp types and wattages: 	
HPS 50W-150W	
PSMH 70W-250W
•	 Choice of heat-resistant prismatic glass refractors (NEMA
distributions I, III and V), or heat-resistant prismatic glass globes
for hazardous area fixtures. Colored and clear polycarbonate
globes and Tuff-skin® † coated glass globes are available but are
NOT approved for use in classified areas. Fixtures with these
globes do NOT comply with code requirements, and should be
used in non-classified areas only. Globes and refractors thread 	
directly into ballast housing.
•	 Mounting hoods include cone-shaped pendant hood, standard
pendant, flexible pendant, ceiling and wall pendants (tapped
for 3/4” or 1” NPT), 25° angle stanchion, and 90° (straight)
stanchion (both tapped for 1-1/4” or 1-1/2” NPT).
•	 Cone hood fixtures for pendant mounting shed dust, dirt and
combustible fibers. Cone hood inhibits build-up that “insulates”
fixture and slows heat transfer, and provides increased surface
area for more effective heat dissipation.

Pendant Cone Fixture with
Prismatic Glass Globe and Guard

Ceiling Mount Fixture
with Prismatic Glass Globe, Guard
and Polyester 30° Angle Reflector

•	 Reflector choice includes standard dome and 30º  angle types,
both made of Fiberglass reinforced white polyester. Highly
resistant to unusually corrosive applications. Reflectors are
vented for cooler, dirt-free operation and maintained lumen
output. They secure to ballast housing with stainless steel
screws threading into stainless steel inserts.
•	 For high corrosion resistance, fixture housing, mounting hoods
and guards are copperfree cast aluminum with baked epoxy
finish, electrostatically applied for uniformity. All exposed
hardware is stainless steel.
•	 Hinge has high lip for added safety during installation
and servicing. Hinge and bolt construction assures 360º
compression at all points on ballast housing gasket for positive
sealing. Swing-away design of captive bolt and nut simplifies
servicing.
•	 Body gaskets and globe gaskets are high-temperature silicone
rubber.
•	 Capacitors are non-PCB type, thermally isolated from ballast.

† Tuff-skin is a registered trademark of Thomas Manufacturing Corp., Parkton, Maryland.
V CSA Certification Only.
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

941

Lighting: Enclosed and Gasketed — Area — HID

•	 Enclosed and gasketed fixtures suitable for use in:
— Marine and wet locations
— A wide range of industrial, chemical processing and other
areas where flammable gases and vapors or combustible
dusts are present under conditions defined by the National
Electrical Code as Class I, Division 2; Class II, Division 1 and
2; and Class III
— For Zone 2, the method of protection is AEx nA nR –
Restricted Breathing/Nonsparking or AEx nR – Restricted
Breathing
— Non-hazardous locations where severe weather conditions,
excessive moisture, dirt, dust, corrosive atmosphere or
high ambient temperatures are encountered. 18% cooler
operation allows use in ambient temperatures up to
149°F/65°C depending on fixture component combinations
•	 Typical applications include:
— Pulp and paper mills
— Processing plants
— Chemical plants
— Oil refineries
— Foundries
— Manufacturing plants
— Storage areas
— Marine applications
•	 Fixtures have NEMA 4X listing.
•	 Suitability includes listing for use where there may be
simultaneous exposure to combustible dusts and flammable
gases and vapors. See listing pages for compliance data on
specific fixture component combinations.

Mercmaster™ III HID 50-250 Watt Luminaires
High Pressure Sodium and Pulse Start Metal Halide

Listed for simultaneous exposure to combustible dusts and flammable gases or vapors.

Lighting: Enclosed and Gasketed — Area — HID

Lighting

Class I, Division 2, Groups A, B, C, D
Class I, Zone 2, AEx nA nR IIC (Z2)
Class I, Zone 2, Ex nR IIC (Z) V
Class I, Zone 2, AEx nR IIC (ZB)

Class II, Division 1 and 2, Groups E, F, G
Class III
Simultaneous Exposure (Class I, Division 2/
Class II, Division 1)

•	 Mogul base porcelain socket with nickel-plated contacts has
392 °C/ 200 °C welded leads, prewired to the ballast. Assures
trouble-free operation in installations where high ambient
temperatures are encountered.
•	 HPS ballasts are High Power Factor (min. P.F. 90%).
•	 A wide range of voltages available (120 to 600 Volt) and ballast
types (Reactor, CWA, CWI and Super CWA).
•	 All Mercmaster III mounting hoods have provision for easy field
installation of fuses in fixtures (see fuse kit listings in this catalog
section).
•	 For electrical protection, a ground wire is provided on each
Mercmaster to bond hood and ballast housing.
•	 The AEx nA nR / Ex nR (V) factory sealed Mercmaster III
prevents vapors and gases from entering the globe chamber.
There are no seals or putty required which will reduce
installation time and installation errors.
•	 The AEx nR Mercmaster III fixture requires all wiring entries to
be sealed.

Standard Materials
•	 Mounting hoods, ballast bodies and guards: copperfree cast
aluminum (less than 4/10 of 1%)
•	 Exposed hardware: stainless steel; latch assemblies have
stainless steel bolt and captive nut; reflectors and guards attach
with strainless steel screws threading into stainless steel inserts.
•	 Reflectors: Fiberglass reinforced white polyester
•	 Globes: heat-resistant prismatic glass
•	 Refractors: heat-resistant prismatic glass

Standard Finishes
•	 Mounting hoods, ballast bodies, guards: epoxy powder coat
finish, electrostatically applied for complete, uniform surface
protection
•	 Reflectors: white polyester finish

Fixtures Outside Type (Salt Water)
Type 4X
IP66

•	 Hot Restrike will restrike HPS lamp immediately when power is
restored after a momentary power interruption. Add suffix -R.
•	 Smart Hot Restrike will immediately restrike HPS lamp when
power is restored after a momentary power interruption. The
smart function removes the hot restrike ignitor from the circuit
if the lamp burns out or is removed from the socket. Eliminates
starter failures caused by prolonged operation with cycling or
failing lamps. Add suffix -SR.
•	 Smart Starter incorporates a 1-1/2-minute timer and performs
as a conventional starter to normally start lamp. Removes
itself from circuit if lamp burns out or is removed from socket.
Eliminates starter failures caused by prolonged operation with
cycling or failing lamps and simplifies finding their location,
reducing maintenance and repair costs. Available for all HPS
and PSMH fixtures. Add suffix -S.
•	 Optional photocell for all fixtures except cone and ceiling mount
provides automatic “on-off” control.
•	 Quartz Auxiliary comes to full brightness immediately and
remains lit until the HID lamp attains 60-70% of full illumination.
Quartz Auxiliary supplied with relay switch and socket to accept
120 V quartz double contact bayonet base lamp (not included).
Add suffix -E to fixture catalog number. ‡

Certifications and Compliances
•	 UL Standard: UL 1598, UL 1598A, UL 844, UL 60079-0, UL
60079-15
•	 UL Listed: E10444

Related Products
•	 Classified area photo controls are also available.

Options
•	 AEx nA nR fixtures are available with a Class I, Zone 2 rating.
Add suffix -Z2.
•	 AEx nR fixtures are available with a Class I, Zone 2 rating. Add
suffix -ZB.
•	 Ex nR fixtures, add suffix -Z V.
•	 Fuses can be field-installed on Mercmaster III fixtures. Kits
include fuse block, wire connectors and screws for attaching to
mounting hood. Fixtures with fuses do not comply with Marine
Type Electric Fixtures Outside Type (Salt Water) requirements
for marine listing. For fuse kits, see Electrical Specifications and
Fuse Kits page.

‡ Fixtures equipped with a quartz auxiliary lamp do not comply with UL requirements and are not suitable for use in classified locations.
V CSA Certification Only.

942

Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

Mercmaster™ III HID 50-250 Watt Luminaires
High Pressure Sodium and Pulse Start Metal Halide

Listed for simultaneous exposure to combustible dusts and flammable gases or vapors.
Class I, Division 2, Groups A, B, C, D
Class I, Zone 2, AEx nA nR IIC (Z2)
Class I, Zone 2, Ex nR IIC (Z) V
Class I, Zone 2, AEx nR IIC (ZB)

Class II, Division 1 and 2, Groups E, F, G
Class III
Simultaneous Exposure (Class I, Division 2/
Class II, Division 1)

Fixtures Outside Type (Salt Water)
Type 4X
IP66

Illustrated Features

Lighting

High Temperature Sockets
Mogul base high-temperature porcelain
sockets.
Aluminum Inner Reflector
Solid aluminum inner reflector (for
refractor ballast housings only) improves
photometric efficiency.
Globe Chamber (Zone 2)
Completely sealed from the ballast
housing and outside vapors/air (nA nR).

"Safety" High
Hinge
Extra-high hinge
provides additional
protection against
accidental
ballast housing
disengagement
during installation
or maintenance.
Stainless Steel
Latch Assembly
Captive, stainless
steel latch assembly
bolt and nut closes
securely, resists
attack of corrosive
atmospheres.
Swing-away design
simplifies servicing.

Terminal Blocks (Zone 2)
A seven-point terminal block is provided
to facilitate wiring. Terminal block
accommodates wire size ranging from #8
to #24 AWG.
Stainless Steel Inserts
Ballast bodies have stainless steel
threaded inserts to receive stainless steel
screws for reflectors and guard. Prevents
"freezing”, allowing guards and reflectors
to be easily removed and replaced at any
time, without damage to the housing.

Ballast Assembly (Zone 2)
Utilizing non-sparking components
avoiding the ignition of gases or vapors
that may be present (nA).
Mounting Hood and Globe Gaskets
Silicone rubber gasket seals out moisture,
dirt and dust. Stays flexible, withstands
high temperatures. Closure design
assures uniform gasket compression.
Electrical Protection
Ground wire provided to bond mounting
hood to ballast housing.

Epoxy Finish
Ballast housing, hoods and guards are
copperfree aluminum with epoxy powder
coat finish.
Photocell
Available for all fixtures except cone and
ceiling mount. Installs through knock-out
in mounting hood. Provides continuous
ON-OFF dusk-to-dawn control.
Heat-Resistant Globes and Refractors
Prismatic glass globes and refractors are
heat-resistant. They thread directly into the
ballast housing and seal against a hightemperature silicone rubber gasket.

Cooler Operating Cone Hood
Larger sloped surface sheds dusts, dirt
and combustible fibers providing better
heat dissipation.

Fuses
Two screws secure fuse kit to mounting
boss in any Mercmaster mounting hood.
Fuse included.
V CSA Certification Only.
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

943

Lighting: Enclosed and Gasketed — Area — HID

Vented Reflectors
Reflectors are thick, tough fiberglass-	
reinforced white polyester, vented for
cooler operation. Quickly attach with
furnished stainless steel screws.

Mercmaster™ III HID 50-250 Watt Emergency Luminaires Accessories and Options
High Pressure Sodium and Pulse Start Metal Halide

Listed for simultaneous exposure to combustible dusts and flammable gases or vapors.

Lighting

Class I, Division 2, Groups A, B, C, D
Class I, Zone 2, AEx nA nR IIC (Z2)
Class I, Zone 2, Ex nR IIC (Z) V
Class I, Zone 2, AEx nR IIC (ZB)

Fixtures Outside Type (Salt Water)
Type 4X
IP66

Quartz Emergency Light for Pulse Start Metal Halide or High Pressure Sodium Fixtures *
Mercmaster fixtures for or metal halide and high pressure sodium lamps can be supplied with a
socket to accept a 150 W or 250 W, 120 V quartz lamp. This D.C. bayonet base socket is in addition
to the standard lamp socket. In the event of a momentary power interruption, the quartz lamp is
automatically switched on. The single ended quartz lamp remains energized until the HID restrikes
and reaches about 60% output.

Quartz Emergency Light

Lighting: Enclosed and Gasketed — Area — HID

Class II, Division 1 and 2, Groups E, F, G
Class III
Simultaneous Exposure (Class I, Division 2/
Class II, Division 1)

The quartz emergency lamp socket is wired to a 120 V tap on the ballast and is therefore
independent of the lighting fixture voltage. No special field wiring is necessary.
Description
Catalog Suffix
For fixture volts of 120, 208, 240 or 277
-MTE
For fixture volts of 480
-48E

Quartz Emergency Light for
HPS
Fixtures
QuartzPSMH
Emergencyor
Light
for Pulse
Start Metal Halide or
High Pressure Sodium Fixtures
HPS Smart
Hot Restrike Accessory for HPS Fixtures
Mercmaster fixtures for high pressure sodium lamps can be supplied with a special ignitor (starter
board). It instantly restrikes a hot high pressure sodium lamp when a momentary power interruption
occurs. This special ignitor, supplied in place of the standard ignitor, is a potted solid state device,
totally factory installed. It is not suitable for field installation.
The hot lamp restart option provides instant restart of 50, 70, 100 and 150 W HPS lamps after
power outages of up to 10 seconds. The lamps restrike instantly at almost full lumens. For power
interruptions of up to 30 seconds, the restart of the high pressure sodium lamp is also instant but
at less than full lumens. The hot lamp restart accessory does not accelerate cold lamp start up or
starting where the power outage is of a duration which has allowed the HPS lamp to cool.

Smart
Hot
Restrike

HPS Smart Hot Restrike Accessory
for HPS Fixtures
HPS Smart Hot Restrike Accessory for HPS Fixtures

Accessory Options

Additional Advantages of the Smart Hot Restrike:
•	 Protects against self destruction in the event of failed, missing or broken lamps,  or socket or
Quartzfailure.
Emergency Light
lead wire
•	 Prevents “End of Life” lamps from continuous cycling over long periods of time.
•	 Remains unaffected by stray voltages, moderate overvoltages, as well as undervoltage
conditions.
•	 Drops into the background during normal lamp operation with exceptionally low insertion loss.
•	 Fully encapsulated construction assures electrical integrity and mechanical vibration protection.
•	 UL recognized component.
Quartz Emergency Light for Pulse Start Metal Halide or
High Pressure Sodium Fixtures

Description
For fixture watts of 50, 70, 100 or 150 (HPS only)

Catalog Suffix
-SR

 Guards: Guards are die-cast copperfree aluminum with baked epoxy finish to match fixtures.
Fixture supplied with stainless steel mounting screws which thread into stainless steel inserts on
fixture housing to attach guard. To order fixture with guard, add suffix -G to catalog number before
adding voltage suffix.
➋ Reflectors: Standard dome and 30° angle polyester reflectors are shown elsewhere in this
catalog section.
➌ Hot Restrike: Instantly restrikes a hot HPS lamp when power is restored after a momentary
outage. Available factory-installed only. To order, add suffix -R to catalog number.
➍ Quartz Emergency Light: When ordered, HPS fixtures will be supplied with a prewired special
DC bayonet base socket to accept a 150W, 120V quartz lamp (not furnished) that automatically
switches on when a power outage occurs. Fixtures ordered with this quartz emergency lamp feature
do NOT comply with requirements for classified areas and should be used only in non-classified
locations. To order, add suffix -E to catalog number and specify if a relay switch is desired.
➎ Photocell and Fuses: Photocontrol are available within the Lighting Section.
 Smart Starter: Performs as a conventional starter in lamp start-up. Removes itself from circuit at
end of lamp life or if lamp is out of socket. Add suffix -S to catalog number.
 Smart Hot Restrike (HPS only): Will immediately restrike HPS lamp when power is restored after
a momentary power interruption. The smart function removes the hot restrike ignitor from the circuit
if the lamp burns out or is removed from the socket. Eliminates starter failures caused by prolonged
operation with cycling or failing lamps. Add suffix -SR to catalog number.
*NOTE: Fixtures equipped with quartz emergency light do not comply with UL requirements and are not suitable for use in classified locations.
V CSA Certification Only.

944

Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

Mercmaster™ III HID 50-250 Watt Luminaires
High Pressure Sodium and Pulse Start Metal Halide

Listed for simultaneous exposure to combustible dusts and flammable gases or vapors.
Class I, Division 2, Groups A, B, C, D
Class I, Zone 2, AEx nA nR IIC (Z2)
Class I, Zone 2, Ex nR IIC (Z) V
Class I, Zone 2, AEx nR IIC (ZB)

Class II, Division 1 and 2, Groups E, F, G
Class III
Simultaneous Exposure (Class I, Division 2/
Class II, Division 1)

Fixtures Outside Type (Salt Water)
Type 4X
IP66

Order using catalog numbering guide below or select catalog number from tables on following pages.
Catalog Numbering Guide
KP

L

70

Lamp Type:
L - High Pressure
Sodium
H or P - Pulse Start
Metal Halide ➊

J5

Hub Size:
75 - 3/4” NPT
10 - 1” NPT
125 - 1-1/4” NPT
stanchion
150 - 1-1/2” NPT
stanchion

Wattage:
10 - 100 W HPS, PSMH
15 - 150 W HPS, PSMH
17 - 175 W PSMH
20 - 200 W PSMH
25 - 250 W PSMH
50 - 50 W HPS	
(MT - Voltage Only)
70 - 70 W HPS, PSMH
17 - 175 W MH V
25 - 250 W MH V

G
Guard Options:
G - Guard
Blank - No Guard

Optical Assembly:
Blank - Glass Globe
J1 - NEMA I Glass
Refractor
J3 - NEMA III Glass
Refractor
J5 - NEMA V Glass
Refractor
G3 - Large Glass Globe

MT

R

Z2

Options:
E - Emergency Quartz
F - Fuse Kit (Specify
Voltage)
R - Hot Restrike	
(50-150 W HPS
only)
S - Smart Starter
SR - Smart Hot
Restrike
K - Kynar Coating
H1 - Photocontrol
120 V
H2 - Photocontrol
208 V
H3 - Photocontrol
240 V
H4 - Photocontrol
277 V
C - Safety Cable
Adapted V
E40 - Export Socket
D - E-40 Export 	
Socket V
T - Terminal Blocks V
V - Anti-Vibration
Modifications V
X - Appledapter ➌
Mounting Hood
Adapter V

Voltage: ➋
MT - 120/208/240/277,
60 Hz
5MT - 120/208/240/
277/480, 60 Hz
48 - 480, 60 Hz
125 - 120, 50 Hz
225 - 225, 50 Hz
226 - 220, 60 Hz
235 - 230, 50 Hz
245 - 240, 50 Hz
C2 - 208, 60 Hz, CWI V
C3 - 240, 60 Hz, CWI V
C6 - 480, 60 Hz, CWI V
C7 - 600, 60 Hz, CWI V
TT - 120/277/347, 60 Hz,
CWA V

Lighting: Enclosed and Gasketed — Area — HID

Mounting:
A - Pendant (rigid
mounting)
C - Ceiling
CH - Pendant Cone Hood
F - Pendant (flexible	
mounting)
ST - 90° Stanchion
S - 25° Stanchion
WB - Wall

10

Lighting

Series:
KP Mercmaster III
250

A

Suffix:
Z2 - Zone 2 suffix
(required for
AEx nA nR
rating)
ZB - Zone 2 suffix
(required for
AEx nR rating)
Z - Zone 2 suffix
(required for 	
Ex nR) V

Reflectors are ordered separately – see Accessories page.
➊ H - Lamp type is for 70W and 100W fixtures only.
P - Lamp type is for 175W, 200W and 250W fixtures only.
➋ Voltages shown are limited to specific combinations.
➌ Appledapter is available for use with the pendant, ceiling and angled stanchion mounting only.
V CSA Certification Only.
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

945

Mercmaster™ III HID 50-250 Watt Luminaire Thermal Performance

Class I, Division 2; Class II, Division 1; Simultaneous Exposure to Hazardous Conditions of Both Classifications
Temperature Identification Numbers of Mercmaster III fixtures.
Class I, Division 2, Groups A, B, C, D
Class I, Zone 2, AEx nA nR IIC (Z2)
Class I, Zone 2, Ex nR IIC (Z) V
Class I, Zone 2, AEx nR IIC (ZB)

Class II, Division 1 and 2, Groups E, F, G
Class III
Simultaneous Exposure (Class I, Division 2/
Class II, Division 1)

Fixtures Outside Type (Salt Water)
Type 4X
IP66

Mercmaster III fixtures are listed for “Simultaneous Exposure” to combinations of Class I, Division 2 and Class II, Division 1 hazardous
conditions.

Lighting: Enclosed and Gasketed — Area — HID

Lighting

“T” Numbers for Mercmaster III Fixtures
Lamp
Watts

Type

50

HPS

70

HPS

100

HPS

150

HPS

70

PSMH

100

PSMH

150

PSMH

175

PSMH

200

PSMH

250

PSMH

175

MH V

250

MH V

Supply
Wire
Temp.
(°F/°C)
194/90
194/90
194/90
194/90
194/90
194/90
194/90
194/90
194/90
194/90
194/90
194/90
194/90
194/90
194/90
194/90
194/90
194/90
194/90
194/90
194/90
257/125
194/90
194/90
221/105
194/90
194/90
194/90
194/90
194/90
194/90
194/90

Ambient
Temp.
(°F/°C)
104/40
131/55
149/65
104/40
131/55
149/65
104/40
104/40
131/55
149/65
104/40
104/40
131/55
104/40
131/55
149/65
104/40
131/55
149/65
104/40
131/55
149/65
104/40
131/55
149/65
104/40
131/55
104/40
131/55
104/40
131/55
104/40

Globe
T3C
T3A
T3A
T3B
T3A
T3
T2D
—
T2D
T2D
T2B
—
T2B
T3A
T3A
T3
T3
T3
T2D
T2B
T2A
T2A
T2B
T2A
T2A
T2B
T2B
T2
T2
T2B
T2A
325

Simultaneous Exposure
Class I, Division 2
Class II, Division 1 Groups E, F and G ➊ Class I, Division2 / Class II, Division 1
Globe &
G3
8”
Globe &
G3
8”
Globe &
G3
8”
Reflector Globe Refractor Globe Reflector Globe Refractor Globe Reflector Globe Refractor
T3B
—
T3C
T4A
T4
—
T6
T3A
T3
—
T3C
T3A
—
T3A
T4
T3B
—
T5
T3
T3
—
T3A
T3
—
T3A
T3C
T3C
—
T4A
T2D
T2D
—
T3
T3A
—
T3C
T4
T3C
—
T6
T3
T3
—
T3A
T3A
—
T3B
T3C
T3C
—
T5
T2D
T2D
—
T3
T3A
—
T3A
T3C
T3B
—
T4A
T2C
T2C
—
T3
T2D
T3
T3
—
T3A (EF) T3 (EF)
—
—
—
—
—
—
—
—
T3B
—
T4A
T4A
T2B
T2B
T2C
T2C
T2D
T3
T3
—
—
T4
T4
—
—
T2B
T2B
T2D
T2D
T2D
—
—
—
—
—
—
—
—
T2B
—
T2C
—
—
—
T3C
T2
—
—
T2B
—
—
—
T3 (EF)
—
—
—
—
—
—
—
T2A
—
T2B
—
—
—
—
—
—
—
—
T3A
—
T3A
—
—
—
T3C
—
—
—
—
T3A
—
T3A
—
—
—
T3C
—
—
—
—
T2
—
T3
—
—
—
T3C
—
—
—
—
T3
—
T3
—
—
—
T3C
—
—
—
T2B
T3
—
T3
—
—
—
T3C
—
—
—
T2A
T2D
—
T2D
—
—
—
T3C
—
—
—
—
T2B
—
T2B
—
—
—
T3C
—
—
—
T2B
T2A
—
T2B
—
—
—
T3C
—
—
—
T2A
T2
—
T2B
—
—
—
T3C
—
—
—
—
T2B
—
T2B
—
—
—
T3C
—
—
—
T2B
T2A
—
T2B
—
—
—
T3C
—
—
—
T2A
T2
—
T2B
—
—
—
—
—
—
—
—
T2B
—
T2B
—
—
—
T3B
—
—
—
—
T2B
—
T2B
—
—
—
—
—
—
—
—
T2
—
T2
—
—
—
—
—
—
—
—
T2
—
T2
—
—
—
—
—
—
—
—
T2B
—
T2B
—
—
—
T3C
—
—
—
—
T2A
—
T2B
—
—
—
T3C
—
—
—
—
325
—
T2
—
—
—
T3B
—
—
—
—

“T” Numbers Represent the Maximum Lamp Temperature for Class I, Division 2 Locations and
Maximum Surface Temperature Under Dust Blanket for Class II, Division 1 Locations.
“T”
Number

T1

350

325

T2

T2A

T2B

T2C

T2D

T3

T3A

T3B

T3C

T4

T4A

T5

T6

Temp.
Range
(˚ºF)

664842

619662

574617

538572

502536

448500

421446

394419

358392

331356

322329

277320

250275

214248

187212

185

Temp.
Range
(°C)

351450

326350

301325

281300

261280

231260

216230

201215

181200

166180

161165

136160

121135

101120

86100

85

➊ All Class II T Numbers are E, F, G unless otherwise indicated.
V CSA Certification Only.

946

Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

Mercmaster™ III HID 50-250 Watt Luminaire Thermal Performance
Class I, Zone 2, AEx nA nR IIC; Class 1 Zone 2, AEx nR IIC; IP66; and NEMA 4X
Temperature Identification Numbers of Mercmaster III Fixtures.
Class I, Division 2, Groups A, B, C, D
Class I, Zone 2, AEx nA nR IIC (Z2)
Class I, Zone 2, Ex nR IIC (Z) V
Class I, Zone 2, AEx nR IIC (ZB)

Class II, Division 1 and 2, Groups E, F, G
Class III
Simultaneous Exposure (Class I, Division 2/
Class II, Division 1)

Fixtures Outside Type (Salt Water)
Type 4X
IP66

Operating Temperatures: “T” Numbers for Zone 2 Mercmaster III Fixtures

The “T” number is established by separately determining the maximum temperature of the globe surface and ballast compartment. The hotter of the two is taken
to determine the “T” number for the overall fixture.

Watts

Type

50

HPS

100

150

70

100

150

175

200

250

HPS

HPS

HPS

PSMH

PSMH

PSMH

PSMH

PSMH

PSMH

Ambient
Temp.
(°F/°C)
104/40

Globe
T4

Globe &
Reflector
T4

Refractor
Only
T6

G3/Refractor
& Reflector
T4

Globe
T4

Globe &
Reflector
T4

Refractor
Only
T6

G3/Refractor
& Reflector
T4

194/90

131/55

T4

T3

T5

T3

T4

T3

T5

T3

194/90

149/65

T3

T3

T4

T3

T3

T3

T4

T3

194/90

104/40

T4

T4

T4

T4

T6

T5

T6

T4

194/90

131/55

T4

T4

T4

T3

T5

T4

T5

T3

194/90

149/65

T4

T4

T3

T3

T4

T4

T5

T3

194/90

104/40

T4

T4

T4

T4

T5

T4

T6

T4

194/90

131/55

T4

T4

T3

T3

T4

T4

T5

T3

194/90

149/65

T4

T4

T3

T3

T4

T4

T4

T3

194/90

104/40

T4

T3

T3

T3

T4

T4

T5

T4

194/90

131/55

T3

T3

T3

T3

T4

T4

T4

T3

221/105

65

T3

T3

T3

T3

T4

T3

T4

T3

194/90

104/40

T4

T4

T4

—

T5

T4

T6

—

194/90

131/55

T3

T3

T3

—

T4

T4

T5

—

194/90

149/65

T3

T3

T3

—

T4

T3

T4

—

194/90

104/40

T3

T3

T3

—

T5

T4

T6

—

194/90

131/55

T3

T3

T3

—

T4

T4

T5

—

194/90

149/65

T3

T3

T3

—

T4

T3

T4

—

194/90

104/40

T4

T4

T4

—

T4

T4

T5

—

Class I, Zone 2 AEx nA nR IIC

Class I, Zone 2 AEx nR IIC

194/90

131/55

T3

T3

T3

—

T4

T3

T4

—

221/105

149/65

T3

T3

T3

—

T4

T3

T4

—

194/90

104/40

T3

T3

T4

—

T3

T3

T4

—

194/90

131/55

T3

T3

T3

—

T3

T3

T4

—

221/105

149/65

T3

T3

T3

—

T3

T3

T4

—

194/90

104/40

T3

T3

T4

—

T3

T3

T4

—

221/105

131/55

T3

T3

T3

—

T3

T3

T4

—

221/105

149/65

T3

T3

T3

—

T3

T3

T4

—

194/90

104/40

T3

T3

T3

—

T3

T3

T3

—

194/90

131/55

T3

T3

T3

—

T3

T3

T3

—

Lighting: Enclosed and Gasketed — Area — HID

70

Supply
Wire
Temp.
(°F/°C)
194/90

“T” Numbers Represent the Maximum Surface Temperature for Luminaries with AEx nA nR or AEx nR rating
“T” Number

T1

T2

T3

T4

T5

T6

Temp. Range (°F)

547-842

394-572

277-392

214-275

187-212

185

Temp. Range (°C)

301-450

201-300

136-200

101-135

86-100

85

V CSA Certification Only.
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

Lighting

Lamp

947

Mercmaster™ III HID 50-250 Watt Luminaire Classified Area Suitability

Class I, Division 2; Class II, Division 1; Simultaneous Exposure to Hazardous Conditions of Both Classifications
Maximum Temperatures in °F/°C Obtained from Tests in a 104 °F/40 °C Ambient, Vertical Position, Lamp Base Up, as per NEC.
Class I, Division 2, Groups A, B, C, D
Class I, Zone 2, AEx nA nR IIC (Z2)
Class I, Zone 2, Ex nR IIC (Z) V
Class I, Zone 2, AEx nR IIC (ZB)

Class II, Division 1 and 2, Groups E, F, G
Class III
Simultaneous Exposure (Class I, Division 2/
Class II, Division 1)

Fixtures Outside Type (Salt Water)
Type 4X
IP66

Fixture Selection Guide Indicates atmosphere for which fixture is suitable

Lighting

 Denotes fixture with Globe Only.     ➋ Denotes fixture with Globe and Reflector.     ➌ Denotes fixture with 8” Refractor / G3 Globe
Ignition
°F/°C ➍

Minimum Fixture
“T” Number for
Chemical

581/305

T2

acrolein (inhibited)

428/220

arsine
butadiene
ethylene oxide
hydrogen
propylene oxide
propylnitrate

NA ➋
788/420
804/429
932/500
840/449
347/175

acetaldehyde
allyl alcohol
n-butyraldehyde
carbon monoxide
crotonaldehyde
cyclopropane
diethyl ether (ethyl ether)
diethylamine
ethylene
ethylenimine

Class I, Division 2 Chemical
Group A Atmospheres
acetylene

HPS (Watts)
50

70

100

PSMH (Watts)
150

70

100

175

➋➌ ➋➌ ➋➌ ➋➌

➋

➋➌ ➋➌

T2D

➋➌ ➋➌ ➋➌

➋

➋➌

350
350
T1
350
T3B

➋➌
➋➌
➋➌
➋➌
➋➌

➋➌
➋➌
➋➌
➋➌
➋➌

➋
➋
➋
➋
➋

➋➌
➋➌
➋➌
➋➌

347/175
712/378
424/218
1128/609
450/232
928/498
320/160
594/312
842/450
608/320

T3B
350
T2D
T1
T2C
T1
T3C
T2
T1
T2

➋➌
➋➌
➋➌
➋➌
➋➌
➋➌
 ➌
➋➌
➋➌
➋➌

➊ ➌
➋➌
➋➌
➋➌
➋➌
➋➌
➌
➋➌
➋➌
➋➌

ethly mercaptan

572/300

ethyl sulfide
hydrogen cyanide

200

250

 ➌

➋

Lighting: Enclosed and Gasketed — Area — HID

Group B Atmospheres

➋➌
➋➌
➋➌
➋➌

➋➌
➋➌
➋➌
➋➌

➋
➋➌
➋➌
➋➌
➋➌

➋➌
➋➌
➋➌
➋➌

➋
➋
➋
➋

➋➌ ➋➌ ➋➌
➋➌
➋➌ ➋➌ ➋➌
➋➌
➋➌ ➋➌ ➋➌

➋
➋
➋
➋
➋

➋➌ ➋➌  ➌
➋➌ ➋➌ ➋➌
➋➌ ➋➌  ➌

➋
➋
➋

Group C Atmospheres

➋➌ ➋➌
➋➌ ➋➌
➋➌ ➋➌

➋
➋
➋
➋
➋
➋
➋
➋
➋
➋

T2

➋➌ ➋➌ ➋➌ ➋➌

➋

➋➌ ➋➌

 ➌

➋

NA ➎
1000/538

T1

➋➌ ➋➌ ➋➌ ➋➌

➋

➋➌ ➋➌ ➋➌

➋

hydrogen sulfide

500/260

T2B

➋➌ ➋➌ ➋➌ ➋➌

➋

➋➌ ➋➌

morpholine
2-nitropropane
tetrahydrofuran
unsymmetrical dimethyl hydrazine

590/310
802/428
610/321
480/249

T2
350
T2
T2C

➋➌
➋➌
➋➌
➋➌

➋➌
➋➌
➋➌
➋➌

➋➌ ➋➌
➋➌ ➋➌
➋➌ ➋➌
➋➌
➌

➋
➋
➋
➋

➋➌ ➋➌  ➌
➋➌ ➋➌ ➋➌
➋➌ ➋➌  ➌
➋➌

➋
➋
➋
➋

867/464
869/465
898/481
1204/651
928/498
549/287
649/343

T1
T1
T1
T1
T1
T2A
325

➋➌
➋➌
➋➌
➋➌
➋➌
➋➌
➋➌

➋➌
➋➌
➋➌
➋➌
➋➌
➋➌
➋➌

➋➌
➋➌
➋➌
➋➌
➋➌
➋➌
➋➌

➋
➋
➋
➋
➋
➋
➋

➋➌
➋➌
➋➌
➋➌
➋➌
➋➌
➋➌

➋
➋
➋
➋
➋
➋
➋

➋➌ ➋➌
➋➌
➋➌ ➋➌
➋➌
➌
➋➌ ➋➌



➋

Group D Atmospheres
acetic acid (glacial)
acetone
acrylonitrile
ammonia
benzene
butane
1-butanol (butyl alcohol)

➋➌
➋➌
➋➌
➋➌
➋➌
➋➌
➋➌

➋➌
➋➌
➋➌
➋➌
➋➌
➋➌
➋➌

➋➌
➋➌
➋➌
➋➌
➋➌

➋➌

This classified area suitability chart is based on NEC requirements and Appleton and UL testing. However, the ultimate decision on suitability of these fixtures for
classified areas depends solely on the judgement of the owner, insurance company, inspector and/or authority having jurisdiction.
➍ Ignition temperatures shown should be regarded as approximations only. Per NFPA Bulletin 325M, ignition temperatures may vary according to such factors
as vapor/air mixture, size and space where ignition may occur, rate and duration of heating, oxygen concentration and other materials present.
➎ Not Available.
➏ A saturated hydrocarbon mixture. Also known by synonyms benzine, ligroin, petroleum, ether and naptha.
V CSA Certification Only.

948

Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

Mercmaster™ III HID 50-250 Watt Classified Area Suitability

Class I, Division 2; Class II, Division 1; Simultaneous Exposure to Hazardous Conditions of Both Classifications
Maximum Temperatures in °F/°C Obtained from Tests in a 104 °F/40 °C Ambient, Vertical Position, Lamp Base Up, as per NEC.
Class I, Division 2, Groups A, B, C, D
Class I, Zone 2, AEx nA nR IIC (Z2)
Class I, Zone 2, Ex nR IIC (Z) V
Class I, Zone 2, AEx nR IIC (ZB)

Class II, Division 1 and 2, Groups E, F, G
Class III
Simultaneous Exposure (Class I, Division 2/
Class II, Division 1)

Fixtures Outside Type (Salt Water)
Type 4X
IP66

Fixture Selection Guide Indicates atmosphere for which fixture is suitable
 Denotes fixture with Globe Only.   ➋ Denotes fixture with Globe and Reflector. ➌ Denotes fixture with 8” Refractor / G3 Globe
PSMH (Watts)

761/405
797/425

350
350

➋➌ ➋➌ ➋➌ ➋➌
➋➌ ➋➌ ➋➌ ➋➌

➋
➋

➋➌ ➋➌ ➋➌
➋➌ ➋➌ ➋➌

➋
➋

isobutyl acetate

790/421

350

➋➌ ➋➌ ➋➌ ➋➌

➋

➋➌ ➋➌ ➋➌

➋

sec-butyl alcohol
di-isobutylene
ethane
ethanol (ethyl alcohol)
ethyl acetate
ethylene diamine (anhydrous)
ethylene dichloride
gasoline (56-60 octane)
heptanes
hexanes
isoprene
isopropyl ether
mesityl oxide
methane (natural gas)
methanol (methyl alcohol)
3-methyl-l-butanol (isoamyl alcohol)
methyl ethyl ketone
methyl isobutyl ketone
2-methyl-1-propanol (isobutyl alcohol)
2-methyl-1-propanol (tertiary butyl alcohol)
petroleum naphtha ➏
pyridine
octanes
pentanes
1-pentanol (amyl alcohol)
propane
1-propanol (propyl alcohol)
2-propanol (isopropyl alcohol)
propylene
styrene
toluene
vinyl acetate

649/343
736/391
882/472
685/363
799/426
725/385
775/413
536/280
399/204
433/223
743/395
829/443
651/344
999/537
725/385
662/350
759/404
838/448
779/415
892/478
550/288
900/482
403/206
500/260
572/300
810/432
774/412
750/399
851/455
914/490
896/480
756/402

325
350
T1
350
350
350
350
T2A
T3
T2D
350
350
325
T1
350
350
350
350
350
T1
T2A
T1
T3
T2B
T2
350
350
350
T1
T1
T1
350

➋➌
➋➌
➋➌
➋➌
➋➌
➋➌
➋➌
➋➌
➋➌
➋➌
➋➌
➋➌
➋➌
➋➌
➋➌
➋➌
➋➌
➋➌
➋➌
➋➌
➋➌
➋➌
➋➌
➋➌
➋➌
➋➌
➋➌
➋➌
➋➌
➋➌
➋➌
➋➌

➋➌
➋➌
➋➌
➋➌
➋➌
➋➌
➋➌
➋➌
➋➌

➋
➋
➋
➋
➋
➋
➋
➋
➋
➋
➋
➋
➋
➋
➋
➋
➋
➋
➋
➋
➋
➋
➋
➋
➋
➋
➋
➋
➋
➋
➋
➋

➋➌
➋➌
➋➌
➋➌
➋➌
➋➌
➋➌
➋➌
➋➌
➋➌
➋➌
➋➌
➋➌
➋➌
➋➌
➋➌
➋➌
➋➌
➋➌
➋➌
➋➌
➋➌
➋➌
➋➌
➋➌
➋➌
➋➌
➋➌
➋➌
➋➌
➋➌
➋➌

vinyl chloride

882/472

T1

➋➌ ➋➌ ➋➌ ➋➌

xylenes (o-xylene)

865/463

T1

➋➌ ➋➌ ➋➌ ➋➌

50

70

➋➌
➋➌
➋➌
➋➌
➋➌
➋➌
➋➌
➋➌
➋➌
➋➌
➋➌
➋➌
➋➌
➋➌
➋➌
➋➌
➋➌
➋➌
➋➌
➋➌
➋➌
➋➌
➋➌
➋➌
➋➌
➋➌
➋➌
➋➌
➋➌
➋➌
➋➌
➋➌

100

➋➌
➋➌
➋➌
➋➌
➋➌
➋➌
➋➌
➋➌
➋➌






➋
➋
➋
➋
➋➌
➋➌
➋➌
➋➌
➋➌
➋➌
➋➌
➋➌
➋➌
➋➌
➋➌
➋➌
➋➌

150

➋➌
➋➌
➋➌
➋➌
➋➌
➋➌
➋➌
➋➌

➋➌
➋➌
➋➌
➋➌
➋➌
➋➌
➋➌
➋➌
➋➌
➋➌
➋➌
➋➌

70

100

175

200

250

➋➌
➋➌
➋➌
➋➌
➋➌
➋➌
➋➌
➋➌

➋➌
➋➌
➋➌
➋➌
➋➌
➋➌
➋➌


➋
➋
➋
➋
➋
➋
➋
➋

➋➌
➋➌
➋➌
➋➌
➋➌
➋➌
➋➌
➋➌
➋➌
➋➌
➋➌
➋➌

➋➌
➋➌
➋➌
➋➌
➋➌
➋➌
➋➌
➋➌
➋➌
➋➌

➋➌

➋
➋
➋
➋
➋
➋
➋
➋
➋
➋
➋
➋

➋➌
➋➌
➋➌
➋➌
➋➌
➋➌
➋➌
➋➌
➋➌


 
➋➌
➋➌

➋➌
➋➌
➋➌
➋➌

➋
➋
➋
➋
➋
➋
➋
➋
➋

➋

➋➌ ➋➌ ➋➌

➋

➋

➋➌ ➋➌ ➋➌

➋

This classified area suitability chart is based on NEC requirements and Appleton and UL testing. However, the ultimate decision on suitability of these fixtures for
classified areas depends solely on the judgement of the owner, insurance company, inspector and/or authority having jurisdiction.
➍ Ignition temperatures shown should be regarded as approximations only. Per NFPA Bulletin 325M, ignition temperatures may vary according to such factors
as vapor/air mixture, size and space where ignition may occur, rate and duration of heating, oxygen concentration and other materials present.
➎ Not Available.
➏ A saturated hydrocarbon mixture. Also known by synonyms benzine, ligroin, petroleum, ether and naptha.
V CSA Certification Only.
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

949

Lighting: Enclosed and Gasketed — Area — HID

Class I, Division 2 Chemical
Group D Atmospheres
2-butanol (secondary butyl alcohol)
n-butyl acetate

Minimum Fixture
“T” Number for
Chemical

Lighting

HPS (Watts)

Ignition
°F/°C ➍

Mercmaster™ III HID 50-250 Watt Luminaire Classified Area Suitability
Class I, Zone 2, AEx nA nR IIC; Class 1 Zone 2, AEx nR IIC; IP66; and NEMA 4X
Maximum Temperatures in ºF/ºC Obtained from Tests in a 104 ºF/40 ºC Ambient, Vertical Position, Lamp Base Up.
Class I, Division 2, Groups A, B, C, D
Class I, Zone 2, AEx nA nR IIC (Z2)
Class I, Zone 2, Ex nR IIC (Z) V
Class I, Zone 2, AEx nR IIC (ZB)

Class II, Division 1 and 2, Groups E, F, G
Class III
Simultaneous Exposure (Class I, Division 2/
Class II, Division 1)

Fixtures Outside Type (Salt Water)
Type 4X
IP66

Fixture Selection Guide Indicates atmosphere for which fixture is suitable

Lighting: Enclosed and Gasketed — Area — HID

Lighting

➋ Denotes fixture with Globe and Reflector.  ➌ Denotes fixture with 8” Refractor.
HPS (Watts)

PSMH (Watts)

Ignition
°F/°C ➍

Minimum Fixture
“T” Number for
Chemical

50

70

100

150

70

100

175

200

250

acetylene

581/305

T2

  ➋➌

  ➋➌

  ➋➌

  ➋➌

  ➋➌

  ➋➌

  ➋➌

  ➋➌

  ➋➌

acetylene

572/300

T2

  ➋➌

  ➋➌

  ➋➌

  ➋➌

  ➋➌

  ➋➌

  ➋➌

  ➋➌

  ➋➌

hydrogen

932/500

T1

  ➋➌

  ➋➌

  ➋➌

  ➋➌

  ➋➌

  ➋➌

  ➋➌

  ➋➌

  ➋➌

914/490

T1

  ➋➌

  ➋➌

  ➋➌

  ➋➌

  ➋➌

  ➋➌

  ➋➌

  ➋➌

  ➋➌

butadiene 1.3

797/425

T2

  ➋➌

  ➋➌

  ➋➌

  ➋➌

  ➋➌

  ➋➌

  ➋➌

  ➋➌

  ➋➌

carbon monoxide coke oven gas

1040/560

T1

  ➋➌

  ➋➌

  ➋➌

  ➋➌

  ➋➌

  ➋➌

  ➋➌

  ➋➌

  ➋➌

diethyl ether (ethyl ether)

320/160

T4

  ➋➌

  ➋➌

  ➋➌

  ➋➌

  ➋➌

ethylene

842/450

T1

  ➋➌

  ➋➌

  ➋➌

  ➋➌

  ➋➌

  ➋➌

  ➋➌

  ➋➌

  ➋➌

ethylenimine ethylene oxide

797/425

T2

  ➋➌

  ➋➌

  ➋➌

  ➋➌

  ➋➌

  ➋➌

  ➋➌

  ➋➌

  ➋➌

acetone

869/465

T1

  ➋➌

  ➋➌

  ➋➌

  ➋➌

  ➋➌

  ➋➌

  ➋➌

  ➋➌

  ➋➌

amyl acetate

707/375

T2

  ➋➌

  ➋➌

  ➋➌

  ➋➌

  ➋➌

  ➋➌

  ➋➌

  ➋➌

  ➋➌

ammonia

1204/651

T1

  ➋➌

  ➋➌

  ➋➌

  ➋➌

  ➋➌

  ➋➌

  ➋➌

  ➋➌

  ➋➌

benzene

928/498

T1

  ➋➌

  ➋➌

  ➋➌

  ➋➌

  ➋➌

  ➋➌

  ➋➌

  ➋➌

  ➋➌

butane

549/287

T3

  ➋➌

  ➋➌

  ➋➌

  ➋➌

  ➋➌

  ➋➌

  ➋➌

  ➋➌

1-butanol (butyl alcohol)

649/343

T2

  ➋➌

  ➋➌

  ➋➌

  ➋➌

  ➋➌

  ➋➌

  ➋➌

  ➋➌

n-butyl acetate cyclohexane

500/260

T3

  ➋➌

  ➋➌

  ➋➌

  ➋➌

  ➋➌

  ➋➌

  ➋➌

  ➋➌

ethyl methyl ketone

959/515

T1

  ➋➌

  ➋➌

  ➋➌

  ➋➌

  ➋➌

  ➋➌

  ➋➌

  ➋➌

  ➋➌

ethanol (ethyl alcohol)

685/363

T2

  ➋➌

  ➋➌

  ➋➌

  ➋➌

  ➋➌

  ➋➌

  ➋➌

  ➋➌

  ➋➌

ethyl acetate

799/426

T1

  ➋➌

  ➋➌

  ➋➌

  ➋➌

  ➋➌

  ➋➌

  ➋➌

  ➋➌

  ➋➌

heptanes

399/204

T3

  ➋➌

  ➋➌

  ➋➌

  ➋➌

  ➋➌

  ➋➌

  ➋➌

  ➋➌

hexanes

433/223

T3

  ➋➌

  ➋➌

  ➋➌

  ➋➌

  ➋➌

  ➋➌

  ➋➌

  ➋➌

isoprene isobutanol

806/430

T2

  ➋➌

  ➋➌

  ➋➌

  ➋➌

  ➋➌

  ➋➌

  ➋➌

  ➋➌

  ➋➌

mesityl oxide methyl acetate

932/500

T1

  ➋➌

  ➋➌

  ➋➌

  ➋➌

  ➋➌

  ➋➌

  ➋➌

  ➋➌

  ➋➌

methanol (methyl alcohol)

725/385

T2

  ➋➌

  ➋➌

  ➋➌

  ➋➌

  ➋➌

  ➋➌

  ➋➌

  ➋➌

  ➋➌

n-propyl acetate

932/500

T1

  ➋➌

  ➋➌

  ➋➌

  ➋➌

  ➋➌

  ➋➌

  ➋➌

  ➋➌

  ➋➌

n-butul acetate

788/420

T2

  ➋➌

  ➋➌

  ➋➌

  ➋➌

  ➋➌

  ➋➌

  ➋➌

  ➋➌

  ➋➌

pentanes

500/260

T3

  ➋➌

  ➋➌

  ➋➌

  ➋➌

  ➋➌

  ➋➌

  ➋➌

  ➋➌

propane

810/432

T2

  ➋➌

  ➋➌

  ➋➌

  ➋➌

  ➋➌

  ➋➌

  ➋➌

  ➋➌

  ➋➌

xylenes (o-xylene)

865/463

T1

  ➋➌

  ➋➌

  ➋➌

  ➋➌

  ➋➌

  ➋➌

  ➋➌

  ➋➌

  ➋➌

Class I, Division 2 Chemical
Group IIC

Group IIB
ethylene

Group IIA

  ➋➌

This classified area suitability chart is based on NEC requirements and Appleton and UL testing. However, the ultimate decision on suitability of these fixtures for
classified areas depends solely on the judgement of the owner, insurance company, inspector and/or authority having jurisdiction.
➍ Ignition temperatures shown should be regarded as approximations only. Per NFPA Bulletin 325M, ignition temperatures may vary according to such factors
as vapor/air mixture, size and space where ignition may occur, rate and duration of heating, oxygen concentration and other materials present.
V CSA Certification Only.

950

Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

Mercmaster™ III HID 50-250 Watt Luminaires
50 W, 70 W, 100 W, 150 W HPS

High Reactance, High Power Factor (min. P.F. 90%). Heat-Resistant Prismatic Glass Globe or Closed Prismatic Glass Refractor. Mogul Base Lamps.
Class I, Division 2, Groups A, B, C, D
Class I, Zone 2, AEx nA nR IIC (Z2)
Class I, Zone 2, Ex nR IIC (Z) V
Class I, Zone 2, AEx nR IIC (ZB)

Class II, Division 1 and 2, Groups E, F, G
Class III
Simultaneous Exposure (Class I, Division 2/
Class II, Division 1)

Lamp Type

Lamp Watts

Hub Size
(Inches)

Fixtures Outside Type (Salt Water)
Type 4X
IP66

Catalog Numbers ➌➍➎
with Type V 8” Refractor
with Globe
or G3 Globe ➋

HPS
HPS
HPS

70
100
150

3/4

KPAL5075

KPAL5075J5

1

KPAL5010

KPAL5010J5

3/4

KPAL7075

KPAL7075J5

1

KPAL7010

KPAL7010J5

3/4

KPAL1075

KPAL1075J5

1

KPAL1010

KPAL1010J5

3/4

KPAL1575

KPAL1575J5

1

KPAL1510

KPAL1510J5

3/4

KPCHL5075

KPCHL5075J5

1  

KPCHL5010

KPCHL5010J5

3/4

KPCHL7075

KPCHL7075J5

1  

KPCHL7010

KPCHL7010J5

3/4

KPCHL1075

KPCHL1075J5

1  

KPCHL1010

KPCHL1010J5

3/4

KPCHL1575

KPCHL1575J5

1  

KPCHL1510

KPCHL1510J5

3/4

KPCL5075

KPCL5075J5

1

KPCL5010

KPCL5010J5

3/4

KPCL7075

KPCL7075J5

1

KPCL7010

KPCL7010J5

3/4

KPCL1075

KPCL1075J5

1

KPCL1010

KPCL1010J5

3/4

KPCL1575

KPCL1575J5

1

KPCL1510

KPCL1510J5

Lighting: Enclosed and Gasketed — Area — HID

HPS

50

Lighting

Pendant — One Hub, Rigid Mounting ➊

Pendant Cone — One Hub, Rigid Mounting
HPS

50

HPS

70

HPS

100

HPS

150

Ceiling — Five Hubs, Four Close-Up Plugs
HPS

50

HPS

70

HPS

100

HPS

150

➊ For Flexible Pendant Mount, change A to F in catalog number (except 50 W HPS).
➋ To order fixtures with large globe change J5 to G3; for fixture with NEMA Type I or NEMA Type III refractor, change final digit 5 in catalog number to 1 or 3.
➌ Add the following voltage and frequency designation before Z2 suffix:
Voltage Suffixes
Lamp Type Lamp Watts
MT
5MT
48
125
225
226
235
245
C2 V
C3 V
C6 V
C7 V
TT V
HPS
50
X
—
—
—
X
X
—
X
—
—
—
—
X
HPS
70
X
—
X
X
X
X
—
X
—
—
—
—
X
HPS
100
X
—
X
X
X
X
—
X
—
—
X
X
X
HPS
150
X
—
X
X
X
X
—
X
—
—
X
X
X
PSMH
70
X
—
X
X
X
—
—
X
—
—
—
—
X
PSMH
100
X
—
X
X
X
—
—
X
—
—
—
—
X
PSMH
150
X
—
X
X
X
—
—
X
—
—
—
—
X
PSMH
175
X
X
X
—
—
—
—
—
—
—
—
—
X
PSMH
200
X
—
X
—
—
—
—
—
—
—
—
—
X
PSMH
250
X
—
—
—
—
—
—
—
—
—
—
—
X
175
X
—
—
X
X
—
—
X
X
X
X
X
X
MH V
250
X
—
—
X
X
—
—
X
X
X
X
X
X
MH V
245 - 240 V 50 Hz
Voltages:
125 - 120 V 50 Hz
MT - 120/208/240/277 V 60 Hz
225 - 225 V 50 Hz
C2 - 208 V 60 Hz, CWI V
5MT - 120/208/240/277/480 V 60 Hz
226 - 220 V 60 Hz
C3 - 240 V 60 Hz, CWI V
C7 - 600 V 60 Hz, CWI V,
48 - 480 V 60 Hz
235 - 230 V 50 Hz
C6 - 480 V 60 Hz, CWI V
TT - 120/277/347 V 60 Hz, CWA V
➍ Add -Z2 suffix for factory sealed non-sparking/restricted breathing protection (AEx nA nR). Add -ZB suffix for restricted breathing protection (AEx nR).
➎ For fixtures with guards, add letter G before adding voltage designation.
V CSA Certification only.
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

951

Mercmaster™ III HID 50-250 Watt Luminaires
50 W, 70 W, 100 W, 150 W HPS

High Reactance, High Power Factor (min. P.F. 90%). Heat-Resistant Prismatic Glass Globe or Closed Prismatic Glass Refractor. Mogul Base Lamps.
Class I, Division 2, Groups A, B, C, D
Class I, Zone 2, AEx nA nR IIC (Z2)
Class I, Zone 2, Ex nR IIC (Z) V
Class I, Zone 2, AEx nR IIC (ZB)

Class II, Division 1 and 2, Groups E, F, G
Class III
Simultaneous Exposure (Class I, Division 2/
Class II, Division 1)

Lighting

Lamp Type
Wall — Five Hubs, Four Close-Up Plugs
HPS

50

HPS

70

HPS

Lighting: Enclosed and Gasketed — Area — HID

Lamp Watts

100

HPS

150

HPS

50

Hub Size
(Inches)

Fixtures Outside Type (Salt Water)
Type 4X
IP66

Catalog Numbers ➌➍➎
with Type V 8” Refractor
with Globe
or G3 Globe ➋

3/4

KPWBL5075

KPWBL5075J5

1

KPWBL5010

KPWBL5010J5

3/4

KPWBL7075

KPWBL7075J5

1

KPWBL7010

KPWBL7010J5

3/4

KPWBL1075

KPWBL1075J5

1

KPWBL1010

KPWBL1010J5

3/4

KPWBL1575

KPWBL1575J5

1

KPWBL1510

KPWBL1510J5

1-1/4

KPSL50125

KPSL50125J5

1-1/2

KPSL50150

KPSL50150J5

1-1/4

KPSL70125

KPSL70125J5

1-1/2

KPSL70150

KPSL70150J5

1-1/4

KPSL10125

KPSL10125J5

1-1/2

KPSL10150

KPSL10150J5

1-1/4

KPSL15125

KPSL15125J5

1-1/2

KPSL15150

KPSL15150J5

1-1/4

KPSTL50125

KPSTL50125J5

1-1/2

KPSTL50150

KPSTL50150J5

1-1/4

KPSTL70125

KPSTL70125J5

1-1/2

KPSTL70150

KPSTL70150J5

1-1/4

KPSTL10125

KPSTL10125J5

1-1/2

KPSTL10150

KPSTL10150J5

1-1/4

KPSTL15125

KPSTL15125J5

1-1/2

KPSTL15150

KPSTL15150J5

25° Stanchion — One Hub

HPS

70

HPS

100

HPS

150

HPS

50

90° Stanchion — One Hub

HPS
HPS
HPS

70
100
150

➊ For Flexible Pendant Mount, change A to F in catalog number (except 50 W HPS).
➋ To order fixtures with large globe change J5 to G3; for fixture with NEMA Type I or NEMA Type III refractor, change final digit 5 in catalog number to 1 or 3.
➌ Add the following voltage and frequency designation before Z2 suffix:
Voltage Suffixes
Lamp Type Lamp Watts
MT
5MT
48
125
225
226
235
245
C2 V
C3 V
C6 V
C7 V
TT V
HPS
50
X
—
—
—
X
X
—
X
—
—
—
—
X
HPS
70
X
—
X
X
X
X
—
X
—
—
—
—
X
HPS
100
X
—
X
X
X
X
—
X
—
—
X
X
X
HPS
150
X
—
X
X
X
X
—
X
—
—
X
X
X
PSMH
70
X
—
X
X
X
—
—
X
—
—
—
—
X
PSMH
100
X
—
X
X
X
—
—
X
—
—
—
—
X
PSMH
150
X
—
X
X
X
—
—
X
—
—
—
—
X
PSMH
175
X
X
X
—
—
—
—
—
—
—
—
—
X
PSMH
200
X
—
X
—
—
—
—
—
—
—
—
—
X
PSMH
250
X
—
—
—
—
—
—
—
—
—
—
—
X
175
X
—
—
X
X
—
—
X
X
X
X
X
X
MH V
250
X
—
—
X
X
—
—
X
X
X
X
X
X
MH V
Voltages:
125 - 120 V 50 Hz
245 - 240 V 50 Hz
MT - 120/208/240/277 V 60 Hz
225 - 225 V 50 Hz
C2 - 208 V 60 Hz, CWI V
5MT - 120/208/240/277/480 V 60 Hz
226 - 220 V 60 Hz
C3 - 240 V 60 Hz, CWI V
C7 - 600 V 60 Hz, CWI V,
235 - 230 V 50 Hz
C6 - 480 V 60 Hz, CWI V
TT - 120/277/347 V 60 Hz, CWA V
48 - 480 V 60 Hz
➍ Add -Z2 suffix for factory sealed non-sparking/restricted breathing protection (AEx nA nR). Add -ZB suffix for restricted breathing protection (AEx nR).
➎ For fixtures with guards, add letter G before adding voltage designation.
V CSA Certification only.

952

Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

Mercmaster™ III HID 50-250 Watt

70 W, 100 W, 150 W, 175 W, 200 W, 250 W PSMH

High Reactance, High Power Factor (min. P.F. 90%). Heat-Resistant Prismatic Glass Globe or Closed Prismatic Glass Refractor. Mogul Base Lamps
Class I, Division 2, Groups A, B, C, D
Class I, Zone 2, AEx nA nR IIC (Z2)
Class I, Zone 2, Ex nR IIC (Z) V
Class I, Zone 2, AEx nR IIC (ZB)

Class II, Division 1 and 2, Groups E, F, G
Class III
Simultaneous Exposure (Class I, Division 2/
Class II, Division 1)

Lamp Type
Pendant — One Hub, Rigid Mounting ➊

Lamp Watts

PSMH

100

PSMH

150

PSMH

175

PSMH

200

PSMH

250 ➏

Pendant Cone — One Hub, Rigid Mounting
PSMH

70

PSMH

100

PSMH

150

PSMH

175

PSMH

200

PSMH

250 ➏

Ceiling — Five Hubs, Four Close-Up Plugs
PSMH

70

PSMH

100

PSMH

150

PSMH

175

PSMH

200

PSMH

250 ➏

3/4
1
3/4
1
3/4
1
3/4
1
3/4
1
3/4
1

KPAH7075
KPAH7010
KPAH1075
KPAH1010
KPAP1575
KPAP1510
KPAP1775
KPAP1710
KPAP2075
KPAP2010
KPAP2575
KPAP2510

KPAH7075J5
KPAH7010J5
KPAH1075J5
KPAH1010J5
KPAP1575J5
KPAP1510J5
KPAP1775J5
KPAP1710J5
KPAP2075J5
KPAP2010J5
KPAP2575J5
KPAP2510J5

3/4
1
3/4
1  
3/4
1
3/4
1
3/4
1
3/4
1

KPCHH7075
KPCHH7010
KPCHH1075
KPCHH1010
KPCHP1575
KPCHP1510
KPCHP1775
KPCHP1710
KPCHP2075
KPCHP2010
KPCHP2575
KPCHP2510

KPCHH7075J5
KPCHH7010J5
KPCHH1075J5
KPCHH1010J5
KPCHP1575J5
KPCHP1510J5
KPCHP1775J5
KPCHP1710J5
KPCHP2075J5
KPCHP2010J5
KPCHP2575J5
KPCHP2510J5

3/4
1
3/4
1
3/4
1
3/4
1
3/4
1
3/4
1

KPCH7075
KPCH7075
KPCH1075
KPCH1010
KPCP1575
KPCP1510
KPCP1775
KPCP1710
KPCP2075
KPCP2010
KPCP2575
KPCP2510

KPCH7075J5
KPCH7010J5
KPCH1075J5
KPCH1010J5
KPCP1575J5
KPCP1510J5
KPCP1775J5
KPCP1710J5
KPCP2075J5
KPCP2010J5
KPCP2575J5
KPCP2510J5

Lighting: Enclosed and Gasketed — Area — HID

70

Catalog Numbers ➌➍➎
with Globe
with Type V 8” Refractor ➋

Lighting

PSMH

Hub Size
(Inches)

Fixtures Outside Type (Salt Water)
Type 4X
IP66

➊ For Flexible Pendant Mount, change A to F in catalog number (except 50 W HPS).
➋ To order fixtures with large globe change J5 to G3; for fixture with NEMA Type I or NEMA Type III refractor, change final digit 5 in catalog number to 1 or 3.
➌ Add the following voltage and frequency designation before Z2 suffix:
Voltage Suffixes
Lamp Type Lamp Watts
MT
5MT
48
125
225
226
235
245
C2 V
C3 V
C6 V
C7 V
TT V
HPS
50
X
—
—
—
X
X
—
X
—
—
—
—
X
HPS
70
X
—
X
X
X
X
—
X
—
—
—
—
X
HPS
100
X
—
X
X
X
X
—
X
—
—
X
X
X
HPS
150
X
—
X
X
X
X
—
X
—
—
X
X
X
PSMH
70
X
—
X
X
X
—
—
X
—
—
—
—
X
PSMH
100
X
—
X
X
X
—
—
X
—
—
—
—
X
PSMH
150
X
—
X
X
X
—
—
X
—
—
—
—
X
PSMH
175
X
X
X
—
—
—
—
—
—
—
—
—
X
PSMH
200
X
—
X
—
—
—
—
—
—
—
—
—
X
PSMH
250
X
—
—
—
—
—
—
—
—
—
—
—
X
175
X
—
—
X
X
—
—
X
X
X
X
X
X
MH V
250
X
—
—
X
X
—
—
X
X
X
X
X
X
MH V
Voltages:
125 - 120 V 50 Hz
245 - 240 V 50 Hz
MT - 120/208/240/277 V 60 Hz
225 - 225 V 50 Hz
C2 - 208 V 60 Hz, CWI V
5MT - 120/208/240/277/480 V 60 Hz
226 - 220 V 60 Hz
C3 - 240 V 60 Hz, CWI V
C7 - 600 V 60 Hz, CWI V,
235 - 230 V 50 Hz
C6 - 480 V 60 Hz, CWI V
TT - 120/277/347 V 60 Hz, CWA V
48 - 480 V 60 Hz
➍ Add -Z2 suffix for factory sealed non-sparking/restricted breathing protection (AEx nA nR). Add -ZB suffix for restricted breathing protection (AEx nR).
➎ For fixtures with guards, add letter G before adding voltage designation.
V CSA Certification only.
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

953

Mercmaster™ III HID 50-250 Watt Luminaires
70 W, 100 W, 150 W, 175 W, 200 W, 250 W PSMH

High Reactance, High Power Factor (min. P.F. 90%). Heat-Resistant Prismatic Glass Globe or Closed Prismatic Glass Refractor. Mogul Base Lamps.
Class I, Division 2, Groups A, B, C, D
Class I, Zone 2, AEx nA nR IIC (Z2)
Class I, Zone 2, Ex nR IIC (Z) V
Class I, Zone 2, AEx nR IIC (ZB)

Class II, Division 1 and 2, Groups E, F, G
Class III
Simultaneous Exposure (Class I, Division 2/
Class II, Division 1)

Lighting: Enclosed and Gasketed — Area — HID

Lighting

Lamp Type
Wall — Five Hubs, Four Close-Up Plugs

Lamp Watts

PSMH

70

PSMH

100

PSMH

150

PSMH

175

PSMH

200

PSMH

250 ➏

PSMH

70

PSMH

100

PSMH

150

PSMH

175

PSMH

200

PSMH

250 ➏

PSMH

70

PSMH

100

PSMH

150

PSMH

175

PSMH

200

PSMH

250 ➏

25° Stanchion — One Hub

Hub Size
(Inches)

Fixtures Outside Type (Salt Water)
Type 4X
IP66

Catalog Numbers ➌➍➎
with Globe
with Type V 8” Refractor ➋

3/4
1
3/4
1
3/4
1
3/4
1
3/4
1
3/4
1

KPWBH7075
KPWBH7010
KPWBH1075
KPWBH1010
KPWBP1575
KPWBP1510
KPWBP1775
KPWBP1710
KPWBP2075
KPWBP2010
KPWBP2575
KPWBP2510

KPWBH7075J5
KPWBH7010J5
KPWBH1075J5
KPWBH1010J5
KPWBP1575J5
KPWBP1510J5
KPWBP1775J5
KPWBP1710J5
KPWBP2075J5
KPWBP2010J5
KPWBP2575J5
KPWBP2510J5

1-1/4
1-1/2
1-1/4
1-1/2
1-1/4
1-1/2
1-1/4
1-1/2
1-1/4
1-1/2
1-1/4
1-1/2

KPSH70125
KPSH70150
KPSH10125
KPSH10150
KPSP15125
KPSP15150
KPSP17125
KPSP17150
KPSP20125
KPSP20150
KPSP25125
KPSP25150

KPSH70125J5
KPSH70150J5
KPSH10125J5
KPSH10150J5
KPSP15125J5
KPSP15150J5
KPSP17125J5
KPSP17150J5
KPSP20125J5
KPSP20150J5
KPSP25125J5
KPSP25150J5

1-1/4
1-1/2
1-1/4
1-1/2
1-1/4
1-1/2
1-1/4
1-1/2
1-1/4
1-1/2
1-1/4
1-1/2

KPSTH70125
KPSTH70150
KPSTH10125
KPSTH10150
KPSTP15125
KPSTP15150
KPSTP17125
KPSTP17150
KPSTP20125
KPSTP20150
KPSTP25125
KPSTP25150

KPSTH70125J5
KPSTH70150J5
KPSTH10125J5
KPSTH10150J5
KPSTP15125J5
KPSTP15150J5
KPSTP17125J5
KPSTP17150J5
KPSTP20125J5
KPSTP20150J5
KPSTP25125J5
KPSTP25150J5

90° Stanchion — One Hub

Shown with Globe and Optional Guard

➊ For Flexible Pendant Mount, change A to F in catalog number (except 50 W HPS).
➋ To order fixtures with large globe change J5 to G3; for fixture with NEMA Type I or NEMA Type III refractor, change final digit 5 in catalog number to 1 or 3.
➌ Add the following voltage and frequency designation before Z2 suffix:
Voltage Suffixes
Lamp Type Lamp Watts
MT
5MT
48
125
225
226
235
245
C2 V
C3 V
C6 V
C7 V
TT V
HPS
50
X
—
—
—
X
X
—
X
—
—
—
—
X
HPS
70
X
—
X
X
X
X
—
X
—
—
—
—
X
HPS
100
X
—
X
X
X
X
—
X
—
—
X
X
X
HPS
150
X
—
X
X
X
X
—
X
—
—
X
X
X
PSMH
70
X
—
X
X
X
—
—
X
—
—
—
—
X
PSMH
100
X
—
X
X
X
—
—
X
—
—
—
—
X
PSMH
150
X
—
X
X
X
—
—
X
—
—
—
—
X
PSMH
175
X
X
X
—
—
—
—
—
—
—
—
—
X
PSMH
200
X
—
X
—
—
—
—
—
—
—
—
—
X
PSMH
250
X
—
—
—
—
—
—
—
—
—
—
—
X
175
X
—
—
X
X
—
—
X
X
X
X
X
X
MH V
250
X
—
—
X
X
—
—
X
X
X
X
X
X
MH V
245 - 240 V 50 Hz
Voltages:
125 - 120 V 50 Hz
MT - 120/208/240/277 V 60 Hz
225 - 225 V 50 Hz
C2 - 208 V 60 Hz, CWI V
5MT - 120/208/240/277/480 V 60 Hz
226 - 220 V 60 Hz
C3 - 240 V 60 Hz, CWI V
C7 - 600 V 60 Hz, CWI V,
48 - 480 V 60 Hz
235 - 230 V 50 Hz
C6 - 480 V 60 Hz, CWI V
TT - 120/277/347 V 60 Hz, CWA V
➍ Add -Z2 suffix for factory sealed non-sparking/restricted breathing protection (AEx nA nR). Add -ZB suffix for restricted breathing protection (AEx nR).
➎ For fixtures with guards, add letter G before adding voltage designation.
V CSA Certification only.

954

Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

Mercmaster™ III HID 50-250 Watt
175 W, 250 W MH V

High Reactance, High Power Factor (min. P.F. 90%). Heat-Resistant Prismatic Glass Globe or Closed Prismatic Glass Refractor. Mogul Base Lamps
Class I, Division 2, Groups A, B, C, D
Class I, Zone 2, AEx nA nR IIC (Z2)
Class I, Zone 2, Ex nR IIC (Z) V
Class I, Zone 2, AEx nR IIC (ZB)

Class II, Division 1 and 2, Groups E, F, G
Class III
Simultaneous Exposure (Class I, Division 2/
Class II, Division 1)

Lamp Type

Lamp Watts

Hub Size
(Inches)

Fixtures Outside Type (Salt Water)
Type 4X
IP66

Catalog Numbers ➌➍➎
with Globe
with Type V 8” Refractor ➋

Pendant — One Hub, Rigid Mounting ➊

175

MH V

250 ➏

KPAH1775

KPAH1775J5

1

KPAH1710

KPAH1710J5

3/4

KPAH2575

KPAH2575J5

1

KPAH2510

KPAH2510J5

3/4

KPCHH1775

KPCHH1775J5

1  

KPCHH1710

KPCHH1710J5

3/4

KPCHH2575

KPCHH2575J5

1

KPCHH2510

KPCHH2510J5

3/4

KPCH1775

KPCH1775J5

1

KPCH1710

KPCH1710J5

3/4

KPCH2575

KPCH2575J5

1

KPCH2510

KPCH2510J5

Lighting: Enclosed and Gasketed — Area — HID

3/4

Lighting

MH V

Pendant Cone — One Hub, Rigid Mounting

MH V

175

MH V

250 ➏

Ceiling — Five Hubs, Four Close-Up Plugs

MH V

175

MH V

250 ➏

➊ For Flexible Pendant Mount, change A to F in catalog number (except 50 W HPS).
➋ To order fixtures with large globe change J5 to G3; for fixture with NEMA Type I or NEMA Type III refractor, change final digit 5 in catalog number to 1 or 3.
➌ Add the following voltage and frequency designation before Z2 suffix:
Voltage Suffixes
Lamp Type Lamp Watts
MT
5MT
48
125
225
226
235
245
C2 V
C3 V
C6 V
C7 V
TT V
HPS
50
X
—
—
—
X
X
—
X
—
—
—
—
X
HPS
70
X
—
X
X
X
X
—
X
—
—
—
—
X
HPS
100
X
—
X
X
X
X
—
X
—
—
X
X
X
HPS
150
X
—
X
X
X
X
—
X
—
—
X
X
X
PSMH
70
X
—
X
X
X
—
—
X
—
—
—
—
X
PSMH
100
X
—
X
X
X
—
—
X
—
—
—
—
X
PSMH
150
X
—
X
X
X
—
—
X
—
—
—
—
X
PSMH
175
X
X
X
—
—
—
—
—
—
—
—
—
X
PSMH
200
X
—
X
—
—
—
—
—
—
—
—
—
X
PSMH
250
X
—
—
—
—
—
—
—
—
—
—
—
X
175
X
—
—
X
X
—
—
X
X
X
X
X
X
MH V
250
X
—
—
X
X
—
—
X
X
X
X
X
X
MH V
245 - 240 V 50 Hz
Voltages:
125 - 120 V 50 Hz
MT - 120/208/240/277 V 60 Hz
225 - 225 V 50 Hz
C2 - 208 V 60 Hz, CWI V
5MT - 120/208/240/277/480 V 60 Hz
226 - 220 V 60 Hz
C3 - 240 V 60 Hz, CWI V
C7 - 600 V 60 Hz, CWI V,
48 - 480 V 60 Hz
235 - 230 V 50 Hz
C6 - 480 V 60 Hz, CWI V
TT - 120/277/347 V 60 Hz, CWA V
➍ Add -Z2 suffix for factory sealed non-sparking/restricted breathing protection (AEx nA nR). Add -ZB suffix for restricted breathing protection (AEx nR).
➎ For fixtures with guards, add letter G before adding voltage designation.
V CSA Certification only.
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

955

Mercmaster™ III HID 50-250 Watt
175 W, 250 W MH V

High Reactance, High Power Factor (min. P.F. 90%). Heat-Resistant Prismatic Glass Globe or Closed Prismatic Glass Refractor. Mogul Base Lamps
Class I, Division 2, Groups A, B, C, D
Class I, Zone 2, AEx nA nR IIC (Z2)
Class I, Zone 2, Ex nR IIC (Z) V
Class I, Zone 2, AEx nR IIC (ZB)

Class II, Division 1 and 2, Groups E, F, G
Class III
Simultaneous Exposure (Class I, Division 2/
Class II, Division 1)

Lighting: Enclosed and Gasketed — Area — HID

Lighting

Lamp Type
Wall — Five Hubs, Four Close-Up Plugs

MH V

Lamp Watts

175

MH V

250 ➏

MH V

175

Hub Size
(Inches)

Fixtures Outside Type (Salt Water)
Type 4X
IP66

Catalog Numbers ➌➍➎
with Globe
with Type V 8” Refractor ➋

KPWBH1775

3/4

KPWBH1775J5

1

KPWBH1710

KPWBH1710J5

3/4

KPWBH2575

KPWBH2575J5

1

KPWBH2510

KPWBH2510J5

1-1/4

KPSH17125

KPSH17125J5

1-1/2

KPSH17150

KPSH17150J5

1-1/4

KPSH25125

KPSH25125J5

1-1/2

KPSH25150

KPSH25150J5

1-1/4

KPSTH17125

KPSTH17125J5

1-1/2

KPSTH17150

KPSTH17150J5

1-1/4

KPSTH25125

KPSTH25125J5

1-1/2

KPSTH25150

KPSTH25150J5

25° Stanchion — One Hub

MH V

250 ➏

MH V

175

MH V

250 ➏

90° Stanchion — One Hub

Shown with Globe and Optional Guard
➊ For Flexible Pendant Mount, change A to F in catalog number (except 50 W HPS).
➋ To order fixtures with large globe change J5 to G3; for fixture with NEMA Type I or NEMA Type III refractor, change final digit 5 in catalog number to 1 or 3.
➌ Add the following voltage and frequency designation before Z2 suffix:
Voltage Suffixes
Lamp Type Lamp Watts
MT
5MT
48
125
225
226
235
245
C2 V
C3 V
C6 V
C7 V
TT V
HPS
50
X
—
—
—
X
X
—
X
—
—
—
—
X
HPS
70
X
—
X
X
X
X
—
X
—
—
—
—
X
HPS
100
X
—
X
X
X
X
—
X
—
—
X
X
X
HPS
150
X
—
X
X
X
X
—
X
—
—
X
X
X
PSMH
70
X
—
X
X
X
—
—
X
—
—
—
—
X
PSMH
100
X
—
X
X
X
—
—
X
—
—
—
—
X
PSMH
150
X
—
X
X
X
—
—
X
—
—
—
—
X
PSMH
175
X
X
X
—
—
—
—
—
—
—
—
—
X
PSMH
200
X
—
X
—
—
—
—
—
—
—
—
—
X
PSMH
250
X
—
—
—
—
—
—
—
—
—
—
—
X
175
X
—
—
X
X
—
—
X
X
X
X
X
X
MH V
250
X
—
—
X
X
—
—
X
X
X
X
X
X
MH V
245 - 240 V 50 Hz
Voltages:
125 - 120 V 50 Hz
MT - 120/208/240/277 V 60 Hz
225 - 225 V 50 Hz
C2 - 208 V 60 Hz, CWI V
5MT - 120/208/240/277/480 V 60 Hz
226 - 220 V 60 Hz
C3 - 240 V 60 Hz, CWI V
C7 - 600 V 60 Hz, CWI V,
48 - 480 V 60 Hz
235 - 230 V 50 Hz
C6 - 480 V 60 Hz, CWI V
TT - 120/277/347 V 60 Hz, CWA V
➍ Add -Z2 suffix for factory sealed non-sparking/restricted breathing protection (AEx nA nR). Add -ZB suffix for restricted breathing protection (AEx nR).
➎ For fixtures with guards, add letter G before adding voltage designation.
V CSA Certification only.

956

Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

Mercmaster™ III HID 50-250 Watt PRE-PAK™ Luminaires
Factory-Assembled Fixtures

For 70 W, 100 W or 150 W High Pressure Sodium Lamps, or 100 W or 175 W Pulse Start Metal Halide Lamps. Mogul Base Lamps.
Class I, Division 2, Groups A, B, C, D
Class I, Zone 2, AEx nA nR IIC (Z2)
Class I, Zone 2, Ex nR IIC (Z) V
Class I, Zone 2, AEx nR IIC (ZB)

Class II, Division 1 and 2, Groups E, F, G
Class III
Simultaneous Exposure (Class I, Division 2/
Class II, Division 1)

Fixtures Outside Type (Salt Water)
Type 4X
IP66

These pre-packaged fixture component combinations are delivered fully assembled and packed in a single carton. They are available with
or without lamp, and with choice of globe or NEMA Type I, III or V refractors – all with or without guards. PRE-PAK units simplify ordering,
stocking and shipping, and result in savings on job-site assembly and installation time and costs.
Lighting

Catalog numbers do not include mounting hood or reflector. For mounting hood and reflectors selection, see below and order
separately. Hood and Reflector will be packaged separately.

Lamp Type
and Watts
100 W PSMH ➋
175 W PSMH
70 W HPS
100 W HPS
150 W HPS
175 W MH V

Ballast Assembly
with Globe Only
KPBU100H-MT
KPBU175P-MT
KPBU70L-MT
KPBU100L-MT
KPBU150L-MT
KPBU175H-TT

Ballast Assembly
with Globe and Guard
KPBU100HG-MT
KPBU175PG-MT
KPBU70LG-MT
KPBU100LG-MT
KPBU150LG-MT
KPBU175HG-TT

250 W MH V

KPBU250H-TT

KPBU250HG-TT

Ballast Assembly
with G3 Globe Only
—
—
—
KPBUG3100L-MT
—
—
—

Pendant
One Hub, Rigid Mounting

Hub Size
Catalog
(Inches)
Number
3/4
KPA-75
1

KPA-100

Pendant — Flexible
One Hub, Flexible Mounting

3/4

KPAF-75

1

KPAF-100

Pendant Cone
One Hub, Rigid

3/4

KPCH-75

1

KPCH-100

Ceiling
Five Hubs,
Four Close-Up Plugs
Wall
Five Hubs,
Four Close-Up Plugs

3/4

KPC-75

1

KPC-100

3/4

KPWB-75

1

KPWB-100

25° Stanchion
One Hub
90° Stanchion
One Hub

Ballast Assembly
with Refractor and Guard
KPBU100HJ5G-MT
KPBU175PJ5G-MT
KPBU70LJ5G-MT
KPBU100LJ5G-MT
KPBU150LJ5G-MT
KPBU175HJ5G-TT

KPBU250HJ5-TT

KPBU250HJ5G-TT

White Polyester Reflectors
Furnished with stainless steel screws

Mounting Hoods
Description

Ballast Assembly
with Refractor Only ➌
KPBU100HJ5-MT
KPBU175PJ5-MT
KPBU70LJ5-MT
KPBU100LJ5-MT
KPBU150LJ5-MT
KPBU175HJ5-TT

1-1/4

KPS-125

1-1/2

KPS-150

1-1/4

KPST-125

1-1/2

KPST-150

Description

Catalog
Number

Standard Dome
For Globe Fixtures

KR2-ST

30° Angle
For Globe Fixtures

KR2-AN

Standard Dome
For Glass Refractor Fixtures

CMR-4ST

30° Angle
For Glass Refractor Fixtures

CMR-4AN

➊ All catalog numbers above are fixtures without lamp. To order fixture complete with appropriate installed lamp, add suffix L to catalog number. All PRE-PAK fixtures
include multi-tap ballast for operation on 120 V, 208 V, 240 V or 277 V lines. Fixture component combinations listed are furnished completely assembled in a single
carton.
➋ 100 W fixtures use ED-28 mogul base lamps.
➌ Refractor catalog numbers listed are for NEMA Type V. To order fixture with Type III refractor, change J5 in catalog number to J3; for Type I refractor, change
J5 to J1.
➍ For CSA 120/277/347 Vac tri-tap ballast, change -MT to -TT V.
V CSA Certification only.
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

957

Lighting: Enclosed and Gasketed — Area — HID

PRE-PAK Fixtures ➊➍

Mercmaster™ III HID 50-250 Watt Luminaire Mounting Hoods
High Pressure Sodium and Pulse Start Metal Halide

Listed for simultaneous exposure to combustible dusts and flammable gases or vapors.

Mounting Hoods
Description

Hub Size (Inches)

Catalog Number

Lighting

Pendant
One Hub, Rigid Mounting

3/4

KPA-75

1

KPA-100

3/4

KPAF-75

1

KPAF-100

3/4

KPCH-75

1

KPCH-100

Pendant — Flexible

Lighting: Enclosed and Gasketed — Area — HID

One Hub, Flexible Mounting
Pendant Cone
One Hub, Rigid
Ceiling
Five Hubs, Four Close-Up Plugs

3/4

KPC-75

1

KPC-100

3/4

KPWB-75

1

KPWB-100

Wall
Five Hubs, Four Close-Up Plugs
25° Stanchion

One Hub

1-1/4

KPS-125

1-1/2

KPS-150

1-1/4

KPST-125

1-1/2

KPST-150

90° Stanchion

One Hub

958

Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

Mercmaster™ III HID 50-250 Watt Luminaire Ballast Bodies
High Pressure Sodium and Pulse Start Metal Halide

Listed for simultaneous exposure to combustible dusts and flammable gases or vapors.
Class I, Division 2, Groups A, B, C, D
Class I, Zone 2, AEx nA nR IIC (Z2)
Class I, Zone 2, Ex nR IIC (Z) V
Class I, Zone 2, AEx nR IIC (ZB)

Class II, Division 1 and 2, Groups E, F, G
Class III
Simultaneous Exposure (Class I, Division 2/
Class II, Division 1)

Fixtures Outside Type (Salt Water)
Type 4X
IP66

Ballast Bodies

Ballast Body for Glass Refractor or G3 Globe (shown)

High Pressure Sodium 	
High Power Factor (Min. P.F. 90%)

Pulse Start Metal Halide 	
Super Constant Wattage Autotransformer (Min. P.F. 90%)

Catalog Number ➋➍➎➏
Lamp
Watts

HPS

For Globe

For G3 Globe ➊/
Refractor

Voltage Suffixes
MT

5MT

48

125

225

226

235

245

C2 V C3 V C6 V C7 V TT V

50 ➌

KPB50L

KPBR50L

X

—

—

—

X

X

—

X

—

—

—

—

X

HPS

70 ➌

KPB70L

KPBR70L

X

—

X

X

X

X

—

X

—

—

—

—

X

HPS

100 ➌

KPB100L

KPBR100L

X

—

X

X

X

X

—

X

—

—

X

X

X

HPS

150 ➌

KPB150L

KPBR150L

X

—

X

X

X

X

—

X

—

—

X

X

X

PSMH

70

KPB70H

KPBR70H

X

—

X

X

X

—

—

X

—

—

—

—

X

PSMH

100

KPB100H

KPBR100H

X

—

X

X

X

—

—

X

—

—

—

—

X

PSMH

150

KPB150P

KPBR150P

X

—

X

X

X

—

—

X

—

—

—

—

X

PSMH

175

KPB175P

KPBR175P

X

X

X

—

—

—

—

—

—

—

—

—

X

PSMH

200

KPB200P

KPBR200P

X

—

X

—

—

—

—

—

—

—

—

—

X

PSMH

250

KPBG250P

KPBR250P

X

—

—

—

—

—

—

—

—

—

—

—

X

MH V

175

KPB175H

KPBR175H

X

—

—

X

X

—

—

X

X

X

X

X

X

MH V

250

KPB250H

KPBR250H

X

—

—

X

X

—

—

X

X

X

X

X

X

Voltages:
LB - Incandescent, 120 V 60 Hz
MT - 120/208/240/277 V 60 Hz
5MT - 120/208/240/277/480 V 60 Hz
48 - 480 V 60 Hz

125 - 120 V 50 Hz
225 - 225 V 50 Hz
226 - 220 V 60 Hz
235 - 230 V 50 Hz

245 - 240 V 50 Hz
C2 - 208 V 60 Hz, CWI V
C3 - 240 V 60 Hz, CWI V
C6 - 480 V 60 Hz, CWI V  

C7 - 600 V 60 Hz, CWI V,
TT - 120/277/347 V 60 Hz, CWA V

➊ For HPS version fixtures only.
➋ After voltage suffix add: -S for Smart Starter.
➌ After voltage suffix add: -SR for Smart Hot Restrike, -R for ballast body with Hot Restrike Ignitor.
➍ Add -E after voltage suffix for ballast body with provision for Quartz Emergency Light. Not suitable for hazardous locations.
➎ Add Z2 suffix for factory sealed non-sparking/restricted breathing protection (AEx nA nR). Add ZB suffix for restricted breathing protection (AEx nR).
➏ Add Z for factory sealed restricted breathing protection (Ex nR) V.
V CSA Certification only.
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

959

Lighting: Enclosed and Gasketed — Area — HID

Lamp
Type

Lighting

Ballast Body for Glass Globe (shown)

Mercmaster™ III HID 50-250 Watt Luminaire Optics
High Pressure Sodium and Pulse Start Metal Halide

Listed for simultaneous exposure to combustible dusts and flammable gases or vapors.

Description

Catalog Number

Prismatic Glass Globes — Heat-Resistant
Lighting

For use in areas where fixture is subject to
extreme thermal shock	
Heat-Resistant

Clear

VPGL-2HR

Amber

VPGL-2AM

Blue

VPGL-2BL

Green

VPGL-2GR

Red

VPGL-2RE

Clear

VPGL3HR

Clear

VPGL-2HRT

Clear

VPGL-2PL

Amber

VPGL-2AMPL

Green

VPGL-2GRPL

Red

VPGL-2REPL

Lighting: Enclosed and Gasketed — Area — HID

Glass Globe

G3 Glass Globe
Tuff-Skin® Coated Prismatic Glass Globes — For Non-Classified Areas
For use in areas where fixture is subject to
extreme thermal shock	
Heat-Resistant

Tuff-Skin® Glass Globe
Polycarbonate Globes — Impact-Resistant ➊

Use 100 watt lamp max. Do not use in
ambients exceeding 77 ºF/25 ºC.

Polycarbonate Globe

➊ Polycarbonate globes are shatter-resistant – for use in processing plants, canneries, dairies, bakeries or anywhere broken glass would prove a hazard. Ideally
suited for areas where vandalism, high replacement and high maintenance costs are a problem. Do not use in ambients exceeding 77 °F/25 °C. For burning in
vertical base-up positions only.

960

Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

Mercmaster™ III HID 50-250 Watt Luminaire Optics
High Pressure Sodium and Pulse Start Metal Halide

Listed for simultaneous exposure to combustible dusts and flammable gases or vapors.

Light Distribution

IES/NEMA Distribution Curves

Catalog Number

Closed Prismatic Glass Refractors — Heat-Resistant

NEMA Type III

LPG-R3

NEMA Type V

LPG-R5

Closed Prismatic Polymeric Refractors
For use with PSMH lamps, 100 W max. 104 °F/40 °C max. ambient temperature.
Suitable for Class II, Division 1 and 2, Groups F, G; NEMA 4X, UL 1598A Marine Type Electric Fixtures Outside Type (Salt Water)

NEMA Type II

LPRF-2CP

NEMA Type III

LPRF-3CP

NEMA Type IV

LPRF-4CP

NEMA Type V

LPRF-5CP

Polymeric Refractor

Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

961

Lighting: Enclosed and Gasketed — Area — HID

LPG-R1

Lighting

Glass Refractor

NEMA Type I

Mercmaster™ III HID 50-250 Watt Luminaire Accessories and Replacement Parts
High Pressure Sodium and Pulse Start Metal Halide

Listed for simultaneous exposure to combustible dusts and flammable gases or vapors.

Item

Description

Catalog Number

White Polyester Reflectors — Furnished with stainless steel screws
Lighting

For Globe Fixtures

Lighting: Enclosed and Gasketed — Area — HID

For Glass Refractor Fixtures ➋

Standard Dome

Standard Dome

KR2-ST

Deep Dome

KR2-DD ➊

30° Angle

KR2-AN

Standard Dome

CMR-4ST

Deep Dome

CMR-4DD ➊

30° Angle

CMR-4AN

Globe Guard       

KGU2

G3 Globe/Refractor
Guard   

KRG2

Globe Gasket

VPGL-GK

G3 Globe/Refractor
Gasket

KRF-GK

30° Angle

Guards

Globe Guard

Refractor Guard

Replacement Globe Gaskets — Silicone Rubber

Globe Gaskets
Retrofit Pendant Mounting Adapter

Permits use of Mercmaster III pendant hood
with 3/4” hub on existing V-51 mounting
hood.

LPAD-1

Mounting Adapter

➊ Dark Skies Compliant.
➋ Fixtures with refractors are not UL Listed when used with reflectors.

962

Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

Mercmaster™ III HID 50-250 Watt Luminaire Ballast Weights and Fuse Kits
High Pressure Sodium and Pulse Start Metal Halide

Listed for simultaneous exposure to combustible dusts and flammable gases or vapors.
Class I, Division 2, Groups A, B, C, D
Class I, Zone 2, AEx nA nR IIC (Z2)
Class I, Zone 2, Ex nR IIC (Z) V
Class I, Zone 2, AEx nR IIC (ZB)

Class II, Division 1 and 2, Groups E, F, G
Class III
Simultaneous Exposure (Class I, Division 2/
Class II, Division 1)

Ballast Housing Weights

Fuse Kits
PSMH
(Wt. Lbs/Kg ➊➋)

—
15.75/7.1
16.75/7.6
17.25/7.8
17.75/8.1
18.5/8.4
19/8.6

Wt. Lbs/Kg ➊
2.25/1.0
2.5/1.1
3/1.4
4/1.8
3.25/1.5
3.75/1.7
5.25/2.4
3.75/1.7
1/0.5
1/0.5

Standard Dome

2.50/1.1

30° Angle

2.50/1.1

240

2

F5

—

277

347 V
480
120
208
240
277

1
1
2
1
2
2
1
1
2
1
2
2
1

F5
F2
F3
—
—
—
—
F2
—
—
—
—
—

—
F2
—
F5
F3
F3
F2
F2
F2
F9
F6
F5
F4

347 V
480
120
208
240
277

1

—

F2

2
1
2
2
1

—
—
—
—
—

F2
F8
F5
F5
F3

347 V

1

F3

F3

347 V
120
208
240
277

70

Component and Accessory Weights
Item
Mounting Hoods
Pendant
Pendant Cone
Ceiling
Wall
25° Stanchion
Straight Stanchion
Refractors, Globes and Guards
8” Glass Refractor/G3 Globe
Glass Globe
Globe Guard
Refractor Guard
Reflectors

347 V
480
120
208

Volts
120
208
240
277

50

100

347 V
480
120
208
240
277

150

347 V
480
120
208
240
277

175

200

250

Fuse Kit Catalog Number

Fuse Quantity
Required
1
2
2
1
1
1
2
2
1
1
2
1
2
2
1
1
2
1
2

HPS
F5
F3
F3
F2
F1
F5
F3
F3
F2
F1
F2
F8
F5
F5
F3
F1
F3
F10
F5

PSMH
—
—
—
—
F1
F4
F3
F3
F2
F2
F1
F6
F4
F3
F3
F2
F2
—
—

➊ Weights are approximate.
➋ Add 1 lbs/0.5 kg for HPS fixtures with Hot Restrike. Add 0.25 lbs/0.1 kg for Quartz Emergency Light.
V CSA Certification only.
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

963

Lighting: Enclosed and Gasketed — Area — HID

—
15.25/6.9
16.25/7.4
16.75/7.6
17.25/7.8
18/8.2
18.5/8.4

Lamp
Watts

Lighting

HPS
Lamp Watts
(Wt. Lbs/Kg ➊➋)
Globe Housing with Ballast
50
12.5/5.7
70
15/6.8
100
16/7.3
150
17/7.7
175
—
200
—
250
—
Refractor Housing with Ballast
50
13/5.9
70
15.5/7.0
100
16.5/7.5
150
17.5/7.9
175
—
200
—
250
—

Fixtures Outside Type (Salt Water)
Type 4X
IP66

Mercmaster™ III HID 50-250 Watt Luminaire Electrical Specifications
High Pressure Sodium and Pulse Start Metal Halide

Listed for simultaneous exposure to combustible dusts and flammable gases or vapors.
Class I, Division 2, Groups A, B, C, D
Class I, Zone 2, AEx nA nR IIC (Z2)
Class I, Zone 2, Ex nR IIC (Z) V
Class I, Zone 2, AEx nR IIC (ZB)

Class II, Division 1 and 2, Groups E, F, G
Class III
Simultaneous Exposure (Class I, Division 2/
Class II, Division 1)

Fixtures Outside Type (Salt Water)
Type 4X
IP66

Lighting: Enclosed and Gasketed — Area — HID

Lighting

Electrical Specifications
Line
Type of
Starting
Voltage
Ballast ➊
Amps
50 Watt High Pressure Sodium
120
HX-HPF
0.58
208
HX-HPF
0.35
240
HX-HPF
0.31
277
HX-HPF
0.25
HX-HPF
0.26
347 V
70 Watt High Pressure Sodium
120
HX-HPF
0.90
208
HX-HPF
0.50
240
HX-HPF
0.44
277
HX-HPF
0.35
HX-HPF
0.30
347 V
480
HX-HPF
0.21
100 Watt High Pressure Sodium
120
HX-HPF
1.30
208
HX-HPF
0.76
240
HX-HPF
0.66
277
HX-HPF
0.60
HX-HPF
0.45
347 V
480
HX-HPF
0.33
480
C.W.I.
0.17
600
C.W.I.
0.14
150 Watt High Pressure Sodium ➋
120
HX-HPF
2.00
208
HX-HPF
1.15
240
HX-HPF
1.00
277
HX-HPF
0.85
HX-HPF
0.52
347 V
480
HX-HPF
0.50
480
C.W.I.
0.25
600
C.W.I.
0.19
70 Watt Pulse Start Metal Halide
120
HX-HPF
0.80
208
HX-HPF
0.50
240
HX-HPF
0.43
277
HX-HPF
0.39
HX-HPF
0.20
347 V
480
HX-HPF
0.26
100 Watt Pulse Start Metal Halide
120
HX-HPF
1.20
208
HX-HPF
0.70
240
HX-HPF
0.61
277
HX-HPF
0.55
HX-HPF
0.40
347 V
480
HX-HPF
0.30

Operating
Amps

Total
Watts

0.58
0.33
0.29
0.25
0.21

64
64
64
64
68

0.82
0.48
0.41
0.36
0.30
0.21

94
94
94
94
94
94

1.15
0.67
0.60
0.52
0.39
0.31
0.30
0.24

130
130
130
130
130
135
130
130

1.70
0.95
0.85
0.72
0.56
0.47
0.42
0.35

188
188
188
188
188
189
190
190

0.85
0.52
0.44
0.39
0.28
0.23

95
95
95
95
88
95

1.15
0.70
0.58
0.50
0.40
0.35

130
130
130
130
129
140

Line
Type of
Starting
Voltage
Ballast ➊
Amps
150 Watt Pulse Start Metal Halide
120
HX-HPF
1.75
208
HX-HPF
1.30
240
HX-HPF
0.85
277
HX-HPF
0.77
Super C.W.A.
0.65
347 V
480
Super C.W.A.
0.45
175 Watt Pulse Start Metal Halide
120
Super C.W.A.
0.90
208
Super C.W.A.
0.50
240
Super C.W.A.
0.35
277
Super C.W.A.
0.30
Super C.W.A.
0.25
347 V
480
Super C.W.A.
0.25

Operating
Amps

Total
Watts

1.60
1.00
0.80
0.70
0.55
0.42

188
188
188
188
185
185

1.78
1.08
0.89
0.76
0.65
0.50

199
199
199
199
208
213

175 Watt Metal Halide V
120
C.W.A.
208
C.W.A.
240
C.W.A.
277
C.W.A.
347
C.W.A.
480
C.W.I.
600
C.W.I.

1.30
0.75
0.65
0.55
0.50
0.20
0.16

1.80
1.04
0.90
0.80
0.65
0.45
0.37

210
210
210
210
210
215
215

175 Watt Metal Halide V
120
Super C.W.A.
208
Super C.W.A.
240
Super C.W.A.
277
Super C.W.A.
480
Super C.W.A.

1.30
0.75
0.65
0.55
0.35

1.80
1.10
0.90
0.80
0.45

213
213
213
213
213

250 Watt Metal Halide V
120
Super C.W.A.
208
Super C.W.A.
240
Super C.W.A.
277
Super C.W.A.
480
Super C.W.A.

1.20
0.65
0.60
0.50
0.30

2.60
1.50
1.30
1.12
0.65

298
298
298
298
298

➊ C.W.A. – Constant Wattage Autotransformer. HX-HPF – High Reactance High Power Factor Autotransformer. Super C.W.A. – Super Constant Wattage Autotransformer.
➋ 150 W HPS units equipped with ballasts to operate 55 volt lamps only.
V CSA Certification only.

964

Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

Mercmaster™ III HID 50-250 Watt Luminaire Dimensions
High Pressure Sodium and Pulse Start Metal Halide

Listed for simultaneous exposure to combustible dusts and flammable gases or vapors.

Ceiling

Pendant
(Rigid or Flex)

13.62”/345.9mm

1.17”/
29.7mm

12.06”/306.3mm

12.06”/306.3mm
1.75”/
44.5mm

Lighting

12.06”/306.3mm

Cone

5.59”/
142.0mm

5.87”/
149.1mm

5.87”/
149.1mm
11.00”/279.4mm

11.00”/279.4mm

11.00”/279.4mm

Wall

17.06”/433.3mm

Globe/Guard/Refractor

1.94”/49.3mm

2.62”/66.5mm

5.87”/
149.1mm

2.75”/69.9mm
6.00”/152.4mm
9.00”/228.6mm

6.50”/
165.1mm
8.00”/
203.2mm

11.00”/279.4mm
17.23”/437.6mm



4.75”/
9.79”/248.7mm
120.7mm

10.17”/
258.3mm



1.87”/47.5mm



15.07”/382.8mm



90º Straight Stanchion



4.00”/
101.6mm

5.87”/

0.94”/
149.1mm
23.9mm

1.94”/49.3mm

16.90”/429.3mm
14.90”/
378.5mm

5.87”/
149.1mm



11.00”/279.4mm



Polymeric Refractor
1.94”/
49.3mm



14.94”/379.5mm

6.06”/
153.9mm

11.00”/279.4mm

5.87”/149.1mm

5.50”/
139.7mm

13.38”/339.9mm

25° Angle Stanchion
6.06”/
153.9mm

8” Globe/Refractor
Body/Guard

13.38”/339.9mm

5.50”/
139.7mm

14.94”/379.5mm

11.00”/279.4mm
5.50”/
139.7mm

1.94”/
49.3mm
5.87”/
149.1mm

5.87”/
149.1mm
11.00”/279.4mm
7.75”/196.9mm

5.87”/149.1mm
7.75”/196.9mm

7.25”/184.2mm

7.78”/199.9mm

11.00”/
11.00”/
279.4mm

10.75”/
273.1mm

7.25”/184.2mm

7.78”/199.9mm

12.38”/
314.5mm

279.4mm
6.69”/
169.9mm

Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

6.69”/
169.9mm

965

Lighting: Enclosed and Gasketed — Area — HID

5.87”/
149.1mm

PCD2 Series Factory Sealed Hazardous Location Photocontrol
For use in Class I, Division 2, Groups A, B, C, D locations

Maintains Class I, Division 2 rating for Mercmaster III – Low Profile, Mercmaster III, and Mercmaster III – 400 Series Luminaires, Mercmaster LED
Class I, Division 2, Groups A, B, C, D
NEMA 4X

Lighting

Applications

Materials

•	 Encapsulated photocontrol provides automatic dusk-to-dawn
lighting control in Class I, Division 2 locations.
•	 Typical applications include walkways, security areas and any
other outdoor lighting application.
•	 For use with Mercmaster III – Low Profile, Mercmaster III, and
Mercmaster III – 400 Series Luminaires.
•	 For remote mounting in FS Boxes.

•	 Encapsulated with epoxy sealing compound
•	 FS: aluminum

Certifications and Compliances
•	 UL Standard: 1604 ­– Hazardous (Classified) Locations
•	 cULus Recognized

Lighting: Enclosed and Gasketed — Area — HID

Features
•	 Factory sealed design eliminates the need for an explosionproof
enclosure.
•	 Can be easily installed in the field.
•	 Solid state design for performance and reliability.
•	 Available for 120, 208, 240, or 277 volts.
•	 50-400 W HID incandescent or fluorescent, 50/60 Hz.
•	 1000 VA Voltage/Ampere
•	 Minimum time delay: 15 seconds to eliminate nuisiance tripping.
•	 Provided with (3) 18AWG stranded leads 6”/152.4mm in length.
•	 Will fit through standard 1/2” knockout.

Factory-Installed Photocontrol

Dimensions

Add to fixture catalog after voltage; i.e.: KPWBL1075MTH1.

Mercmaster III wall mounting hood
with photocontrol installed shown

Voltage Range

Suffix Designation

120 V, 50/60 Hz

H1

208 V, 50/60 Hz

H2

240 V, 50/60 Hz

H3

277 V, 50/60 Hz

H4
1.13”
28.7
mm
1.13”
28.7 mm

Photocontrol in FS Cover for Use with FS/FD Box

Supplied with two stainless steel screws. For neoprene gasket, order catalog number FS-GKR-1N.

Voltage Range

Catalog Number

120V, 50/60 Hz

FSKA-PC120D2

208-277V, 50/60 Hz

FSKA-PC247D2

1.375”
34.9
mm
1.375”
34.9 mm
2.56”
65.0
mm
2.56”
65.0 mm

1.13”
28.7 mm

Photocontrol for Field Installation
Max. Current

Catalog Number

120 V, 50/60 Hz

Voltage Range

8.3 Amp

PC120D2

208-277 V, 50/60 Hz

3.5 Amp

34.9 mm
PC247D2

2.56”
65.0 mm

966

1.375”

0.69”
17.5 mm
1.19”
30.2 mm

1.94”
49.2 mm

Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

Mercmaster™ III HID 50-250 Watt Luminaire Photometric Data
150 W HPS

Listed for simultaneous exposure to combustible dusts and flammable gases or vapors.
* Photometric data is based on fixtures with
150-watt clear High Pressure Sodium lamp
(16,000 lumen).

Zone

Lumens
50.74

10-20

164.55

20-30

310.47

Total Luminaire Efficiency = 86.1%

REPORT NUMBER: KP15LG
Lamps: 150 W High Pressure Sodium with Globe only *

CIE Type – Semi-Direct
Spacing
Criteria

Plane

30-40

611.05

0-180

2.82

Coefficients of Utilization – Zonal Cavity Method

40-50

961.13

90-270

2.82

Effective Floor Cavity Reflectance 0.20

50-60

1308.18

Diagonal

2.80

60-70

1542.35

70-80

1716.10

80-90

1799.18

% Ceiling Rcc
% Walls

70

50

30

10

0

Rw 70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0
0 95 95 95 95 89 89 89 89 77 77 77 67 67 67 57 57 57 53

Lumens % Lamp % Fixture

1 81 74 69 64 75 69 64 59 59 55 51 50 47 44 42 39 37 33

90-100 1802.19

0-30

525.75

3.3

3.8

2 71 62 54 47 65 57 50 44 49 43 38 41 36 32 33 30 27 23

100-110 1676.86

0-40

1136.81

7.1

8.3

3 64 52 44 37 58 48 41 34 41 35 30 34 29 25 28 24 20 17

110-120 1379.11

0-60

3406.12 21.3

24.7

4 57 45 36 30 53 42 34 28 35 29 24 29 24 20 24 19 16 13

120-130 441.46

0-90

8463.75 52.9

61.4

5 52 40 31 24 48 37 29 23 31 24 19 26 20 16 21 16 13 10

130-140

9.61

90-120 4858.16 30.4

35.3

6 48 35 26 20 44 32 25 19 27 21 16 23 17 13 18 14 11

8

140-150

3.33

90-130 5299.62 33.1

38.5

7 44 31 23 17 40 29 21 16 24 18 14 20 15 11 16 12

9

7

150-160

0.74

90-150 5312.56 33.2

38.5

8 40 28 20 15 37 26 19 14 22 16 12 18 13 10 15 11

8

6

160-170

0.00

90-180 5313.30 33.2

38.6

9 38 25 18 13 35 24 17 12 20 14 10 17 12

8 14 10

7

5

170-180

0.00

180-0 13777.05 86.1

100.0

7 13

6

4

Zone
0-10

Lumens

Total Luminaire Efficiency = 73.6%

266.98

CIE Type – Direct

10-20

799.41

20-30

1337.05

9 15 11

9

REPORT NUMBER: KP15LST
Lamps: 150 W High Pressure Sodium with
Standard Dome Reflector *

Spacing
Criteria

Plane

10 35 23 16 11 32 22 15 11 18 13

30-40

1732.06

0-180

1.46

Coefficients of Utilization - Zonal Cavity Method

40-50

2067.60

90-270

1.46

Effective Floor Cavity Reflectance 0.20

50-60

2317.60

Diagonal

1.68

60-70

2210.81

70-80

866.77

80-90

145.09

Lumens % Lamp % Fixture

1 79 76 72 69 77 74 71 68 71 68 66 68 66 64 65 64 62 60

90-100

14.46

0-30

2403.44 15.0

20.4

2 71 65 59 55 69 63 58 54 61 57 53 58 55 52 56 53 50 49

100-110

8.75

0-40

4135.50 25.8

35.1

3 64 56 49 44 62 55 49 44 52 47 43 50 46 42 48 45 41 40

110-120

7.93

0-60

8520.70 53.3

72.3

4 58 49 42 36 57 48 41 36 46 40 36 44 39 35 42 38 35 33

120-130

4.51

0-90

11743.37 73.4

99.7

5 53 43 36 31 52 42 35 30 40 35 30 39 34 30 38 33 29 28

130-140

2.16

90-120

31.14

0.2

0.3

6 49 38 31 26 47 38 31 26 36 30 26 35 30 25 34 29 25 24

140-150

0.48

90-130

35.65

0.2

0.3

7 45 34 27 23 44 34 27 23 33 27 22 31 26 22 30 26 22 20

150-160

0.00

90-150

38.29

0.2

0.3

8 42 31 24 20 40 31 24 20 30 24 20 29 23 19 28 23 19 18

160-170

0.00

90-180

38.29

0.2

0.3

9 39 28 22 18 38 28 22 18 27 21 17 26 21 17 25 21 17 16

170-180

0.00

180-0 11781.65 73.6

100.0

10 36 26 20 16 35 26 20 16 25 19 16 24 19 16 23 19 15 14

% Ceiling Rcc
% Walls

Zonal Lumen Summary
Zone

80

70

50

30

10

0

Rw 70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0
0 88 88 88 88 86 86 86 86 82 82 82 78 78 78 75 75 75 73

Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

967

Lighting: Enclosed and Gasketed — Area — HID

Zonal Lumen Summary
Zone

80

Lighting

0-10

For candlepower values of fixtures with other
HPS lamps, use the following multipliers: for
70 W (6,400 lumen) HPS lamp – 0.40; for 50 W
(4,000 lumen) HPS lamp – 0.25. For candlepower
values of fixture with guard, multiply by 0.95.

Mercmaster™ III HID 50-250 Watt Luminaire Photometric Data
150 W HPS

Listed for simultaneous exposure to combustible dusts and flammable gases or vapors.
* Photometric data is based on fixtures with
150-watt clear High Pressure Sodium lamp
(16,000 lumen).

Lighting: Enclosed and Gasketed — Area — HID

Lighting

Zone

Lumens

Total Luminaire Efficiency = 73.1%

0-10

222.62

CIE Type - Direct

10-20

664.6

20-30

1084.32

30-40

1536.55

For candlepower values of fixtures with other
HPS lamps, use the following multipliers: for
70 W (6,400 lumen) HPS lamp – 0.40; for 50 W
(4,000 lumen) HPS lamp – ­0.25. For candlepower
values of fixture with guard, multiply by 0.95.

REPORT NUMBER: KP15LAN
Lamps: 150 W High Pressure Sodium with
30° Angle Dome Reflector *

Spacing
Criteria

Plane
0-180

Coefficients of Utilization - Zonal Cavity Method

2.06

40-50

1771.90

90-270

1.58

50-60

1771.51

Diagonal

1.62

60-70

1668.93

70-80

1422.36

80-90

994.54

90-100

432.23

Effective Floor Cavity Reflectance 0.20
% Ceiling Rcc
% Walls

Zonal Lumen Summary

70

50

30

10

0

Rw 70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0
0 86 86 86 86 84 84 84 84 79 79 79 75 75 75 71 71 71 70

Lumens % Lamp % Fixture

1 76 71 67 63 73 69 65 62 65 62 59 62 59 57 58 56 54 52

0-30

1971.54 12.3

16.9

2 68 60 54 49 65 58 53 48 55 50 46 52 48 45 49 46 43 41

100-110 104.58

0-40

3508.09 21.9

30.0

3 61 52 45 39 59 50 44 39 48 42 37 45 40 36 43 39 35 33

110-120

20.99

0-60

7051.50 44.1

60.3

4 55 45 38 32 53 44 37 32 42 36 31 39 34 30 37 33 29 27

120-130

1.21

0-90

11137.33 69.6

95.2

5 50 40 33 27 49 39 32 27 37 31 26 35 30 25 33 29 25 23

130-140

0.04

90-120

557.80

3.5

4.8

6 46 36 28 23 45 35 28 23 33 27 22 31 26 22 30 25 21 20

140-150

0.00

90-130

559.01

3.5

4.8

7 43 32 25 20 41 31 25 20 30 24 19 28 23 19 27 22 19 17

150-160

0.00

90-150

559.04

3.5

4.8

8 40 29 22 18 38 28 22 17 27 21 17 26 21 17 25 20 16 15

160-170

0.00

90-180

559.04

3.5

4.8

9 37 26 20 16 36 26 20 16 25 19 15 24 19 15 23 18 15 13

170-180

0.00

180-0 11696.38 73.1

100.0

10 35 24 18 14 33 24 18 14 23 17 14 22 17 13 21 16 13 12

Zone

Lumens

Zone

80

Total Luminaire Efficiency = 81.1%

REPORT NUMBER: KP15LJR5
Lamps: 150 W High Pressure Sodium with
8” Prismatic Glass Refracter - NEMA Type V *

CIE Type - Semi- Direct

0-10

72.83

10-20

222.26

20-30

380.73

30-40

621.11

0-180

1.98

Coefficients of Utilization - Zonal Cavity Method

40-50

852.53

90-270

1.98

Effective Floor Cavity Reflectance 0.20

50-60

1765.29

Diagonal

3.40

60-70

3192.58

70-80

2366.61

80-90

1230.65

90-100

Spacing
Criteria

Plane

% Ceiling Rcc
% Walls

Zonal Lumen Summary
Zone

80

70

50

30

10

0

Rw 70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0
0 93 93 93 93 89 89 89 89 82 82 82 76 76 76 70 70 70 67

Lumens % Lamp % Fixture

1 80 73 68 63 76 70 65 61 64 60 56 58 55 52 53 50 48 45

450.14

0-30

675.83

4.2

5.2

2 69 59 51 45 65 56 49 43 51 45 40 46 41 37 41 37 34 31

100-110 712.41

0-40

1296.93

8.1

10.0

3 61 49 40 33 57 47 38 32 42 35 29 38 32 27 34 29 25 22

110-120 499.15

0-60

3914.76 24.5

30.2

4 54 42 32 25 51 40 31 24 35 28 22 32 26 21 28 23 19 16

120-130 323.44

0-90

10704.60 66.9

82.5

5 49 36 27 20 46 34 26 19 31 23 18 27 21 16 24 19 15 12

130-140 185.00

90-120 1661.70 10.4

12.8

6 45 32 23 16 42 30 22 16 27 20 14 24 18 13 21 16 12 10

140-150

81.31

90-130 1985.14 12.4

15.3

7 41 28 20 14 38 27 19 13 24 17 12 21 15 11 19 14 10

8

150-160

21.08

90-150 2251.45 14.1

15.3

8 38 25 17 12 36 24 16 11 22 15 10 19 14

6

160-170

2.81

90-180 2275.34 14.2

17.5

170-180

0.00

180-0 12979.94 81.1

100.0

968

9 35 23 15 10 33 22 15 10 20 13
10 33 21 14

9 31 20 13

9 18 12

9 17 12

8

9 18 12

8 16 11

7

5

8 16 11

7 15 10

6

5

Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

Mercmaster™ III HID 50-250 Watt Luminaire Photometric Data
175 W PSMH

Listed for simultaneous exposure to combustible dusts and flammable gases or vapors.
* Photometric data is based on fixtures with a
175-watt clear Pulse Start Metal Halide lamp
(17,500 lumen).

Zone

Lumens
57.98

10-20

217.30

20-30

372.71

Total Luminaire Efficiency = 75.4%

REPORT NUMBER: KP17PG
Lamps: 175 W Pulse Start Metal Halide with Globe only *

CIE Type - General Diffuse

Lighting

0-10

For candlepower values of fixtures with other
PSMH lamps, use the following multipliers: for a
100 W (8,500 lumen) PSMH lamp – 0.49; for a 70
W (6,200 lumen) PSMH lamp – 0.36; for a 200 W
(21,000 lumen) PSMH lamp – 1.2. For candlepower
values of fixture with guard, multiply by 0.95.

30-40

696.29

Coefficients of Utilization - Zonal Cavity Method

40-50

1009.65

Effective Floor Cavity Reflectance 0.20

50-60

1226.57

% Ceiling Rcc

60-70

1473.76

% Walls Rw 70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0

70-80

1757.30

80-90

1902.34

Lumens

70

50

30

10

0

0 93 93 93 93 87 87 87 87 75 75 75 64 64 64 54 54 54 50

% Lamp % Fixture

1 79 73 68 63 73 68 63 59 58 54 50 48 45 43 40 37 35 31

90-100 1946.09

0-30

647.99

3.7

4.3

2 70 61 54 47 65 57 50 44 48 42 38 39 35 32 32 29 26 22

100-110 1829.51

0-40

1344.28

7.7

9.0

3 63 52 44 37 58 48 41 35 40 34 29 33 28 24 27 23 20 16

110-120 1657.20

0-60

3580.49

20.5

24.0

4 57 45 37 30 52 42 34 28 35 29 24 29 24 20 23 19 16 12

120-130 750.27

0-90

8713.89

49.8

58.4

5 52 40 31 25 47 37 29 23 31 24 20 25 20 16 20 16 13 10

130-140

14.15

90-120

5432.80

31.0

36.4

6 47 35 27 21 43 32 25 19 27 21 17 22 17 14 18 14 11

8

140-150

4.47

90-130

6183.06

35.3

41.4

7 44 31 23 18 40 29 22 17 24 18 14 20 15 12 16 12

9

7

150-160

0.52

90-150

6201.69

35.4

41.6

8 40 28 21 15 37 26 19 14 22 16 12 18 14 10 15 11

8

6

160-170

1.35

90-180

6203.74

35.4

41.6

9 37 26 18 13 34 24 17 13 20 15 11 17 12

9 13 10

7

5

170-180

0.18

180-0

14917.63

85.2

100.0

8 12

6

4

Zone
0-10

Lumens

Total Luminaire Efficiency = 72.3%

285.95

CIE Type - Direct

10-20

876.46

20-30

1472.88

9 15 11

9

REPORT NUMBER: KP17PST
Lamps: 175 W Pulse Start Metal Halide with
Standard Dome Reflector *

Spacing
Criteria

Plane

10 35 23 16 12 32 22 15 11 18 13

30-40

1924.39

0-180

1.50

Coefficients of Utilization - Zonal Cavity Method

40-50

2213.42

90-270

1.50

Effective Floor Cavity Reflectance 0.20

50-60

2305.55

Diagonal

1.66

60-70

2256.32

70-80

1115.75

80-90

198.05

% Ceiling Rcc

80

70

50

30

10

0

% Walls Rw 70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0
Zonal Lumen Summary
Zone

Lumens

0 86 86 86 86 84 84 84 84 80 80 80 77 77 77 74 74 74 72

% Lamp % Fixture

1 78 74 71 68 76 72 69 67 69 67 65 67 64 63 64 62 61 59

90-100

3.56

0-30

2635.28

15.1

20.8

2 70 63 58 54 68 62 57 53 59 55 52 57 54 50 55 52 49 48

100-110

0.00

0-40

4559.67

26.1

36.0

3 63 55 48 43 61 54 48 43 51 46 42 49 45 41 47 44 41 39

110-120

0.00

0-60

9078.64

51.9

71.8

4 57 48 41 36 56 47 40 35 45 39 35 43 38 34 42 37 34 32

120-130

0.00

0-90

12648.77

72.3

100.0

5 52 42 35 30 51 41 35 30 40 34 30 38 33 29 37 32 29 27

130-140

0.00

90-120

3.56

0.00

0.00

6 48 38 31 26 47 37 30 26 36 30 25 34 29 25 33 29 25 23

140-150

0.00

90-130

3.56

0.00

0.00

7 44 34 27 22 43 33 27 22 32 26 22 31 26 22 30 25 22 20

150-160

0.00

90-150

3.56

0.00

0.00

8 41 31 24 20 40 30 24 20 29 24 19 28 23 19 27 23 19 18

160-170

0.00

90-180

3.56

0.00

0.00

9 38 28 22 18 37 28 22 17 27 21 17 26 21 17 25 21 17 16

170-180

0.00

180-0

12652.33

72.3

100.0

10 36 26 20 16 35 25 20 16 25 19 16 24 19 15 23 19 15 14

Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

969

Lighting: Enclosed and Gasketed — Area — HID

Zonal Lumen Summary
Zone

80

Mercmaster™ III HID 50-250 Watt Luminaire Photometric Data
175 W PSMH

Listed for simultaneous exposure to combustible dusts and flammable gases or vapors.
* Photometric data is based on fixtures with a
175-watt clear Pulse Start Metal Halide lamp
(17,500 lumen).

Lighting: Enclosed and Gasketed — Area — HID

Lighting

Zone

For candlepower values of fixtures with other
PSMH lamps, use the following multipliers: for
a 100 W (8,500 lumen) PSMH lamp – 0.49; for 70
W (6,200 lumen) PSMH lamp – 0.36; for a 200 W
(21,000 lumen) PSMH lamp – 1.2. For candlepower
values of fixture with guard, multiply by 0.95.

Lumens

Total Luminaire Efficiency = 67.1%

0-10

240.21

CIE Type - Direct

10-20

750.99

20-30

1195.39

30-40

1662.85

0-180

1.96

40-50

1830.67

90-270

1.70

50-60

1740.13

Diagonal

1.56

60-70

1571.75

70-80

1324.18

80-90

900.65

90-100

367.96

0-30

2186.59

12.5

18.6

2 63 56 51 46 61 55 49 45 52 47 44 49 45 42 46 43 41 39

100-110 107.38

0-40

3849.44

22.0

32.8

3 57 48 42 37 55 47 41 37 45 40 36 42 38 35 40 37 34 32

110-120

27.79

0-60

7420.24

42.4

63.2

4 51 42 36 31 50 41 35 30 39 34 30 37 33 29 35 31 28 26

120-130

5.54

0-90

11216.82

64.1

95.6

5 47 38 31 26 45 37 30 26 35 29 25 33 28 25 32 27 24 22

130-140

4.20

90-120

503.12

2.9

4.3

6 43 34 27 22 42 33 27 22 31 26 22 30 25 21 28 24 21 19

140-150

4.42

90-130

508.66

2.9

4.3

7 40 30 24 20 39 30 24 19 28 23 19 27 22 19 26 22 18 17

150-160

2.00

90-150

517.28

3.0

4.4

8 37 27 21 17 36 27 21 17 26 20 17 25 20 16 24 19 16 15

160-170

1.70

90-180

521.31

3.0

4.4

9 35 25 19 15 33 25 19 15 24 18 15 23 18 15 22 18 14 13

170-180

0.33

180-0 11738.13

67.1

100.0

10 32 23 17 14 31 23 17 14 22 17 13 21 16 13 20 16 13 12

Zone

Lumens

0-10

22.77

10-20

171.20

20-30

325.41

REPORT NUMBER: KP17PAN
Lamps: 175 W Pulse Start Metal Halide with
30° Angle Dome Reflector *

Spacing
Criteria

Plane

Coefficients of Utilization - Zonal Cavity Method
Effective Floor Cavity Reflectance 0.20
% Ceiling Rcc

80

70

50

30

10

0

% Walls Rw 70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0
Zonal Lumen Summary
Zone

Lumens

0 79 79 79 79 77 77 77 77 73 73 73 69 69 69 66 66 66 64

% Lamp % Fixture

1 70 66 62 59 68 64 61 58 60 58 55 57 55 53 54 52 51 49

Total Luminaire Efficiency = 81.1%

REPORT NUMBER: KP17PJR5
Lamps: 175 W Pulse Start Metal Halide with
8” Prismatic Glass Refracter - NEMA Type V *

CIE Type - Semi-Direct
Spacing
Criteria

Plane

30-40

531.35

0-180

1.66

Coefficients of Utilization - Zonal Cavity Method

40-50

1173.62

90-270

1.64

Effective Floor Cavity Reflectance 0.20

50-60

1165.11

Diagonal

1.92

60-70

3171.29

70-80

3719.35

80-90

1751.05

90-100

% Ceiling Rcc

80

70

50

30

10

0

% Walls Rw 70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0
Zonal Lumen Summary
Zone

Lumens

0 94 94 94 94 90 90 90 90 83 83 83 77 77 77 71 71 71 69

% Lamp % Fixture

1 78 71 65 60 74 68 62 57 62 57 53 57 53 49 51 48 46 43

523.23

0-30

519.38

3.0

3.7

2 67 57 48 41 63 54 46 39 49 42 36 44 38 33 39 35 31 28

100-110 716.53

0-40

1050.73

6.0

7.4

3 59 46 37 29 55 44 35 28 40 32 26 35 29 24 32 26 22 19

110-120 431.18

0-60

3389.46

19.4

23.9

4 52 39 30 22 49 37 28 21 33 26 20 30 23 18 26 21 16 14

120-130 265.20

0-90

12031.16

68.7

84.8

5 47 34 24 17 45 32 23 17 29 21 15 26 19 14 23 17 13 10

130-140 142.69

90-120

1670.94

9.5

11.8

6 43 30 21 14 41 28 20 14 25 18 12 23 16 11 20 15 10

8

140-150

57.09

90-130

1936.15

11.1

13.7

7 40 27 18 12 37 23 17 11 23 16 10 20 14

9 18 13

8

6

150-160

13.48

90-150

2135.93

12.2

15.1

8 37 24 16 10 35 23 15 10 20 14

8 16 11

7

5

9 18 12

160-170

2.44

90-180

2152.72

12.3

15.2

9 34 22 14

9 32 21 13

8 19 12

8 17 11

7 15 10

6

4

170-180

0.88

180-0

14183.88

81.1

100.0

10 32 20 12

8 30 19 12

7 17 11

7 16 10

6 14

5

4

970

9

Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

Mercmaster™ III HID 50-250 Watt Luminaire Photometric Data
175 W PSMH

Listed for simultaneous exposure to combustible dusts and flammable gases or vapors.
* Photometric data is based on fixtures with a
175-watt clear Pulse Start Metal Halide lamp
(17,500 lumen).

Candela
657
668
784

Lumens

TOTAL LUMINAIRE EFFICIENCY = 70.8%
CIE Type – Semi-Direct
Spacing Criteria: 1.7

65
224
451

1194

705

45
55
65
75
85
90
95
105
115
125
135
145
155
165
175
180

871
1267
1309
1430
1528
1537
1552
1452
1339
68
19
13
7
1
2
7

711
1142
1303
1509
1661

Degree
0
5
15

Candela
2785
2797
2902

Lumens

25

2931

1358

35

2979

1821

45
55
65
75
85

2388
2393
2044
664
150

1874
2145
2034
856       
183

90

24

95
105
115
125
135
145
155
165
175
180

5
16
91
5
7
8
2
2
2
11

COEFFICIENTS OF UTILIZATION - ZONAL CAVITY METHOD

ZONAL LUMEN SUMMARY
ZONE LUMENS %LAMP %FIXT.
0-30                 
740
4.2
6.0
0-40 1445
8.3 11.7
0-60 3297
18.8 26.6
0-90 7770
44.4 62.7
90-120 4444
25.4 35.9
90-130 4586
26.2 37.0
90-150 4613
26.4 37.2
90-180 4617
26.4 37.3
0-180 12387
70.8 100.0

1680
1532
1232
143
16
11
3
1
0

TOTAL LUMINAIRE EFFICIENCY = 65.6%
CIE Type – Direct
Spacing Criteria: 1.5

269
823

90°

950

60°

ZONAL LUMEN SUMMARY
ZONE LUMENS %LAMP %FIXT.
0-30                  2450
14.0 21.3
0-40 4271
24.4 37.2
0-60 8290
47.4 72.2
0-90 11363
64.9 99.0
90-120
101
0.6
0.9
90-130
110
0.6
1.0
90-150
115
0.7
1.0
90-180
118
0.7
1.0
0-180 11481
65.6 100.0

11
17
73
9
3
2
2
0
1

45.0
2333
2467
2753
2891
3100
2719
2939
2801
2621

90.0
2333
2321
2337
2480
2544
1993
1791
776
392

135.0
2333
2205
2160
2242
2027
832
421
74
3

85 2729

967

117

5

0 709

662
461
175
8
11
3
5
3
3
5
6

11
3
11
8
13
3
11
5
8
3
6

5
11
19
29
13
3
5
5
5
3
6

5
16 247
21 109
90 56
11
2
0
1
0
4
0
2
0
1
0
0
6

1601
790
413
117
5
0
5
0
5
0
6

EFFECTIVE FLOOR CAVITY REFLECTANCE 0.20
70
50
30
10 70 50 30 10 50 30 10 50 30 10
78 73 73 73 73 64 64 64 56 56 56
53 62 57 53 49 49 46 43 42 39 37
40 54 48 42 37 41 36 32 34 31 27
31 49 40 34 29 34 29 25 29 25 21
25 44 35 29 24 30 25 20 25 21 17
21 40 31 24 20 26 21 17 22 18 14
18 37 27 21 16 23 18 14 20 15 12
15 34 25 18 14 21 16 12 18 13 10
13 31 22 16 12 19 14 11 16 12 9
11 29 20 15 11 17 13 9 15 11 8
10 27 18 13 9 16 11 8 14 10 7

50
48
35
28
24
21
18
16
15
13
12
11

10
30
48
33
26
21
17
15
13
11
10
9
8

10
48
31
23
18
14
12
10
9
7
7
6

0
0
44
28
20
15
12
9
8
7
6
5
4

REPORT NUMBER: KPB175PG3_ST
Lamps: 175 W Pulse Start Metal Halide ED28 Mogul Base with
G3 Globe and Standard Dome Reflector

180.0
2333
2141
2099
2120
1367
546
154
0
0

45°

2850

0°              15°                   30°

Plane
0°
90°
180°

0
0
65
53

  3
  4
  5
  6
  7
  8
  9
10

58
52
48
44
40
37
35
33

50
44
39
35
31
28
26
24

44
38
32
28
25
22
20
18

40
33
28
24
21
18
16
15

56
51
46
42
39
36
34
32

49
43
38
34
30
28
25
23

44
37
32
28
25
22
20
18

39
33
28
24
21
18
16
15

47
41
36
33
29
27
24
23

42
36
31
27
24
22
19
18

39
32
27
23
20
18
16
14

45
39
35
31
28
26
24
22

41
35
30
27
24
21
19
17

38
32
27
23
20
18
16
14

43
38
34
30
27
25
23
21

40
34
30
26
23
21
19
17

37
31
26
23
20
18
16
14

35
29
25
21
19
16
15
13

REPORT NUMBER: KPB175PG3_AN
Lamps: 175 W Pulse Start Metal Halide ED28 Mogul Base with
G3 Globe and 30° Angle Dome Reflector

Flux CIE Type – Direct
223
692
1170
1512
1427
1533
1349
1140

EFFECTIVE FLOOR CAVITY REFLECTANCE 0.20
RC
80
70
50
30
10
RW 70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10
  0 78 78 78 78 76 76 76 76 73 73 73 69 69 69 66 66 66
  1 71 67 64 62 69 66 63 61 63 61 59 60 58 57 58 56 55

  2 64 58 53 49 62 57 52 48 54 50 47 52 49 46 50 47 45 43

1500

TOTAL LUMINAIRE EFFICIENCY = 58.2%

0.0
2333
2491
2904
3010
3471
2978
3296
3153
3175

90
95
105
115
125
135
145
155
165
175
180

70
78
67
59
53
48
43
40
37
34
32
29

80
50 30
78 78
61 57
51 45
44 37
38 31
33 26
29 23
26 20
24 17
22 16
20 14

COEFFICIENTS OF UTILIZATION - ZONAL CAVITY METHOD
75°

Candela Distribution
0
5
15
25
35
45
55
65
75

RC
RW
  0
  1
  2
  3
  4
  5
  6
  7
  8
  9
10

Spacing
Criteria
1.8
1.5
1.1

COEFFICIENTS OF UTILIZATION - ZONAL CAVITY METHOD
EFFECTIVE FLOOR CAVITY REFLECTANCE 0.20
RC
80
70
50
30
RW 70 50 30 10 70 50 30 10 50 30 10 50 30 10 50
  0 69 69 69 69 67 67 67 67 63 63 63 60 60 60 57
  1 61 57 54 51 59 56 53 50 53 50 48 50 48 46 48

10
0
30 10 0
57 57 56
46 45 43

  2 55 49 44 40 53 48 43 40 45 42 38 43 40 37 41 38 36 34
ZONAL LUMEN SUMMARY
ZONE LUMENS %LAMP %FIXT.
  0-30 2085
11.9 20.5
0-40 3597
20.6 35.3
0-60 6557
37.5 64.4
  0-90 9755
55.7 95.8
90-120
412
2.4
4.1
90-130
415
2.4
4.1
90-150
420
2.4
4.1
90-180
423
2.4
4.2
  0-180 10178
58.2 100.0

Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

0-deg
90-deg
180-deg

  3
  4
  5
  6
  7
  8
  9
10

49
45
41
38
35
33
30
28

42
37
33
30
27
24
22
20

37
32
27
24
21
19
17
16

33
27
23
20
18
16
14
12

48
43
40
37
34
32
29
28

41
36
32
29
26
24
22
20

36
31
27
24
21
19
17
15

32
27
23
20
17
15
14
12

39
34
31
28
25
23
21
19

35
30
26
23
20
18
17
15

31
26
22
19
17
15
14
12

37
33
29
26
24
22
20
19

34
29
25
22
20
18
16
15

31
26
22
19
17
15
13
12

35
31
28
25
23
21
19
18

32
28
24
22
19
17
16
14

30
25
21
19
16
15
13
12

28
24
20
17
15
13
12
11

971

Lighting: Enclosed and Gasketed — Area — HID

966

35

Lighting

25

REPORT NUMBER: KPB175PG3
Lamps: 175 W Pulse Start Metal Halide ED28 Mogul Base with
G3 Globe only

Legend

Degree
0
5
15

For candlepower values of fixtures with other
PSMH lamps, use the following multipliers: for a
100 W (8,500 lumen) PSMH lamp – 0.49; for a 70
W (6,200 lumen) PSMH lamp – 0.36; for a 200 W
(21,000 lumen) PSMH lamp – 1.2. For candlepower
values of fixture with guard, multiply by 0.95.

Mercmaster™ III HID 50-250 Watt Luminaire Photometric Data
100 W HPS

Listed for simultaneous exposure to combustible dusts and flammable gases or vapors.

Degree
0
5

Candela
269
267

Lumens

15
25
35
45
55
65
75
85
90
95
105
115
125
135
145
155
165
175
180

407
571
748
451
848
915
976
1021
1027
1019
953
791
54
13
13
4
0
0
1

117
267
442
380
735
908
1033
1113

Degree

Candela

0
5

1466
1473

15
25
35
45
55
65
75
85
90
95
105
115
125
135
145
155
165
175
180

1607
1675
1757
1316
1502
1377
465
92
16
3
6
40
5
3
3
2
0
1
1

For candlepower values of fixtures with other
HPS lamps, use the following multipliers: for a 70
W (6,400 lumen) HPS lamp – 0.68; for 50 W (4,000
lumen) HPS lamp – 0.43; for candlepower values
of fixture with guard, multiply by 0.95.

REPORT NUMBER: KPB100LG3
Lamps: 100 W High Pressure Sodium C100S54 ED23 - 1/2
Mogul Base with G3 Globe only

TOTAL LUMINAIRE EFFICIENCY = 84.1%
CIE Type – Semi-Direct
Spacing Criteria: 3.1

27

RC
RW
0
1
2
3
4
5
6
7
8
9
10

ZONAL LUMEN SUMMARY
ZONE LUMENS %LAMP %FIXT.
0-30                  410
4.3
5.1
0-40
852
9.0
10.7
0-60 1967
20.7
24.6
0-90 5021
52.9
62.9
90-120 2845
29.9
35.6
90-130 2948
31.0
36.9
90-150 2965
31.2
37.1
90-180 2967
31.2
37.1
0-180 7988
84.1 100.0

1109
1002
734
103
9
8
2
0
0

Lumens
142
456
775
1071
1047
1316
1362
589
111

Candela Distribution

Plane
0°
90°

Criteria
1.9
1.7

35
45
55
65
75

180°

1.3

1923
1715
1981
1923
1879

85 1371
90
95
105
115
125
135
145
155
165
175
180

972

680
416
191
40
1
1
0
0
0
2
2

1830 1593 1256 1020 917
1564 1163 599 361 848
1862 1100 287 122 953
1751 869 104
0 869
1272 298
9
0 711
828

140

1

0 424

422
259
93
18
3
2
1
1
1
2
2

89
47
4
51
3
3
2
2
1
2
2

2
4
7
54
3
2
0
1
1
1
2

1
4 144
6 59
92 31
1
2
1
1
0
1
0
1
0
0
0
0
2

0
0
53
32
23
17
13
10
8
7
6
5
5

10
74
60
49
40
33
28
24
21
19
17
15

0
0
72
59
47
38
32
26
23
20
17
15
14

EFFECTIVE FLOOR CAVITY REFLECTANCE 0.20
RC
80
70
50
30
10
RW 70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10
0 77 77 77 77 75 75 75 75 71 71 71 67 67 67 64 64 64
1 68 64 61 57 66 62 59 56 59 56 54 56 54 52 53 51 50

0
0
62
48

70
93
79
69
62
56
51
47
43
40
37
34

70
87
78
70
63
57
52
48
44
41
38
36

COEFFICIENTS OF UTILIZATION - ZONAL CAVITY METHOD
EFFECTIVE FLOOR CAVITY REFLECTANCE 0.20
80
70
50
30
10
50 30 10 70 50 30 10 50 30 10 50 30 10 50 30
87 87 87 85 85 85 85 81 81 81 77 77 77 74 74
74 71 68 76 73 70 67 70 67 65 67 64 62 64 62
64 58 53 68 62 57 53 59 55 51 57 53 50 54 52
55 48 43 61 54 47 43 51 46 42 49 45 41 47 43
48 41 35 55 47 40 35 45 39 34 43 38 34 41 37
42 35 30 51 41 34 29 39 34 29 38 33 29 36 32
37 30 25 46 37 30 25 35 29 25 34 29 25 33 28
34 27 22 43 33 26 22 32 26 22 31 25 21 29 25
30 24 19 40 30 24 19 29 23 19 28 23 19 27 22
23 21 17 37 27 21 17 26 21 17 25 20 17 25 20
25 19 15 35 25 19 15 24 19 15 23 19 15 23 18

REPORT NUMBER: KPB100LG3_AN
Lamps: 100 W High Pressure Sodium C100S54 ED23 - 1/2
Mogul Base with G3 Globe and 30° Angle Reflector

TOTAL LUMINAIRE EFFICIENCY = 65.0%

0.0 45.0 90.0 135.0 180.0 Flux CIE Type – Direct
0 1270 1270 1270 1270 1270
Spacing
5 1317 1302 1271 1227 1211 122
15 1554 1471 1384 1341 1298 398
25 1779 1680 1528 1353 1246 694

10
57
36
26
20
16
13
11
9
8
7
6

RC
RW
  0
  1
  2
  3
  4
  5
  6
  7
  8
  9
10

ZONAL LUMEN SUMMARY
ZONE LUMENS %LAMP %FIXT.
0-30                  1373
14.5
19.8
0-40 2445
25.7
35.3
0-60 4807
50.6
69.4
0-90 6869
72.3
99.2
90-120
45
0.5
0.6
90-130
53
0.6
0.8
90-150
56
0.6
0.8
90-180
58
0.6
0.8
0-180 6927
72.9 100.0

5              
6          
33      
8
2
1
1
1   
0     

COEFFICIENTS OF UTILIZATION - ZONAL CAVITY METHOD
EFFECTIVE FLOOR CAVITY REFLECTANCE 0.20
80
70
50
30
10
50 30 10 70 50 30 10 50 30 10 50 30 10 50 30
93 93 93 87 87 87 87 76 76 76 66 66 66 57 57
72 67 62 73 67 62 58 58 54 50 49 46 43 41 39
60 52 46 64 56 49 43 48 42 37 40 36 32 33 30
51 43 36 57 47 40 34 40 34 29 34 29 24 28 24
44 36 29 51 41 33 27 35 28 23 29 24 20 24 19
39 30 24 47 36 28 22 30 24 19 25 20 16 21 17
34 26 20 43 32 24 19 27 21 16 23 17 13 19 14
31 23 17 40 28 21 16 24 18 14 20 15 13 17 13
28 20 15 37 26 19 14 22 16 12 19 14 10 15 11
25 18 13 34 23 17 12 20 14 10 17 12 9 14 10
23 16 11 32 21 15 11 18 13 9 16 11 8 13 9

REPORT NUMBER: KPB100LG3_ST
Lamps: 100 W High Pressure Sodium C100S54 ED23 - 1/2
Mogul Base with G3 Globe and Standard Dome Reflector

TOTAL LUMINAIRE EFFICIENCY = 72.9%
CIE Type – Direct
Spacing Criteria: 1.6

COEFFICIENTS OF UTILIZATION - ZONAL CAVITY METHOD

2 61 55 49 45 59 53 48 44 50 46 43 48 44 41 45 42 40 38
ZONAL LUMEN SUMMARY
ZONE LUMENS %LAMP %FIXT.
0-30 1213  
12.8
19.7
0-40 2131
22.4
34.5
0-60 3932
41.4
63.7
0-90 5936
62.5
96.1
90-120
234
2.5
3.8
90-130
236
2.5
3.8
90-150
238
2.5
3.9
90-180
239
2.5
3.9
  0-180 6175
65.0 100.0

Legend

Lighting: Enclosed and Gasketed — Area — HID

Lighting

* Photometric data is based on fixtures with a
100-watt clear High Pressure Sodium lamp
(9,400 lumen).

0-deg
90-deg
180-deg

3
4
5
6
7
8
9
10

55
50
46
42
39
36
34
32

47
41
37
33
30
27
25
23

41
35
30
26
23
21
19
17

36
30
25
22
19
17
15
14

53
48
44
41
38
35
33
31

46
40
36
32
29
26
24
22

40
34
30
26
23
21
19
17

36
30
25
22
19
17
15
13

44
38
34
30
28
25
23
21

39
33
29
25
22
20
18
17

35
29
25
21
19
16
15
13

41
36
32
29
26
24
22
20

37
32
28
24
22
20
18
16

34
28
24
21
18
16
14
13

39
35
31
28
25
23
21
20

36
31
27
24
21
19
17
16

33
28
24
20
18
16
14
13

31
26
22
19
17
15
13
12

Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

Mercmaster™ III HID 50-250 Watt Luminaire Photometric Data
150 W HPS

Listed for simultaneous exposure to combustible dusts and flammable gases or vapors.
* Photometric data is based on fixtures with a
150-watt clear High Pressure Sodium lamp
(16,000 lumen).

Lumens

15
25
35
45
55
65
75
85
90
95
105
115
125
135
145
155
165
175
180

703
938
1107
892
1420
1542
1629
1675
1665
1643
1515
1072
51
20
19
6
1
0
2

202
442
672
710
1253
1529
1723
1824

Degree

Candela

46

1788
1599
1042
115
16
12
4
0
0

ZONAL LUMEN SUMMARY
ZONE LUMENS %LAMP %FIXT.
0-30                 
689
4.3
5.3
0-40
1361
8.5
10.5
0-60
3324
20.8
25.6
0-90
8400
52.5
64.7
90-120
4429
27.7
34.1
90-130
4544
28.4
35.0
90-150
4572
28.6
35.2
90-180
4576
28.6
35.3
0-180 12976
81.1 100.0

Lumens

TOTAL LUMINAIRE EFFICIENCY = 69.6%

0
5

2403
2391

15

2624

744

25

2678

1247

REPORT NUMBER: KPB150LG3
Lamps: 150 W High Pressure Sodium C100S54 ED23 - 1/2 Mogul
Base with G3 Globe only

TOTAL LUMINAIRE EFFICIENCY = 81.1%
CIE Type – Semi-Direct
Spacing Criteria: 3.0

RC
RW
0
1
2
3
4
5
6
7
8
9
10

10
30
56
38
29
23
19
16
14
12
11
10
9

10
56
36
26
20
16
13
11
9
8
7
6

0
0
53
32
23
17
13
10
8
7
6
5
4

REPORT NUMBER: KPB150LG3_ST
Lamps: 150 W High Pressure Sodium C100S54 ED23 - 1/2 Mogul
Base with G3 Globe and Standard Dome Reflector

CIE Type – Direct
Spacing Criteria: 1.6

230

70
90
76
67
60
54
49
45
41
38
36
33

COEFFICIENTS OF UTILIZATION - ZONAL CAVITY METHOD
EFFECTIVE FLOOR CAVITY REFLECTANCE 0.20
80
70
50
30
50 30 10 70 50 30 10 50 30 10 50 30 10 50
90 90 90 84 84 84 84 74 74 74 65 65 65 56
70 65 60 71 65 60 56 56 53 49 48 45 42 41
58 51 44 62 54 47 42 46 41 36 39 35 31 33
49 41 34 55 46 38 32 39 33 28 33 28 24 27
43 34 29 50 40 32 26 34 27 22 28 23 19 23
37 29 23 45 35 27 21 30 23 18 25 20 16 21
33 25 19 42 31 23 18 26 20 15 22 17 13 18
30 22 16 38 27 20 15 24 18 13 20 15 11 16
27 19 14 35 25 18 13 21 16 11 18 13 10 15
24 17 12 33 23 16 12 19 14 10 17 12 8 14
22 15 11 31 21 14 10 18 12 9 15 11 7 13

35

2705

1673

COEFFICIENTS OF UTILIZATION - ZONAL CAVITY METHOD

45
55
65
75
85

2250
2444
2246
655
147

1754
2161
2192
851
174

EFFECTIVE FLOOR CAVITY REFLECTANCE 0.20
RC
80
70
50
30
10
0
RW 70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0
0 83 83 83 83 81 81 81 81 77 77 77 74 74 74 70 70 70 69
1 75 71 68 65 73 70 67 64 66 64 62 64 62 60 61 59 58 56

90

26

95
105
115
125
135
145
155
165
175
180

6
11
73
7
6
4
4
2
2
1

ZONAL LUMEN SUMMARY
ZONE LUMENS %LAMP
0-30                  2221
13.9
0-40
3895
24.3
0-60
7809
48.8
0-90 11027
68.9
90-120
92
0.6
90-130
104
0.6
90-150
109
0.7
90-180
112
0.7
0-180 11139
69.6

8
13
71
12
3
2
2
1
0

2 67 61 56 51 65 60 55 51 57 53 49 54 51 48 52 49 47 45

%FIXT.
19.9
35.0
70.1
99.0
0.8
0.9
1.0
1.0
100.0

3
4
5
6
7
8
9
10

Candela Distribution
TOTAL LUMINAIRE EFFICIENCY = 61.0%
0.0 45.0 90.0 135.0 180.0 Flux CIE Type – Direct
0 1964 1964 1964 1964 1964
Spacing

25 2755 2587 2288 2095 1853 1081
35
45
55
65
75
85
90
95
105
115
125
135
145
155
165
175
180

2924
2790
3166
3188
3145
2533

2763
2552
2937
2913
2547
927

1490 640
765 449
380 163
114
4
2
5
2
6
0
2
2
4
4
3
0
2
2
2

2415 1885 1276 1416
2015 780 518 1368
1945 410 157 1520
777 77
0 1380
408
1
2 1118
117
0
2 663
14
5
6
6
7
7
6
6
5
3
2

5
8
11
18
8
8
4
6
4
3
2

9
11 239
15 106
63 44
7
5
6
4
2
3
4
2
2
1
2
0
2

Plane
0°

Criteria
2.0

90°

1.7

180°

1.3

ZONAL LUMEN SUMMARY
ZONE LUMENS %LAMP %FIXT.
0-30
1886
11.8
19.3
0-40
3302
20.6
33.8
0-60
6190
38.7
63.5
0-90
9351
58.4
95.9
90-120
389
2.4
4.0
90-130
395
2.5
4.0
90-150
401
2.5
4.1
90-180
404
2.5
4.1
0-180
9754
61.0 100.0

52
46
40
36
32
29
27
24

46
39
33
29
26
23
20
19

41
34
28
24
21
18
16
15

59
53
48
44
41
38
35
33

51
45
39
35
32
29
26
24

46
38
33
29
25
23
20
18

41
34
28
24
21
18
16
15

49
43
38
34
30
28
25
23

44
37
32
28
25
22
20
18

40
33
28
24
21
18
16
14

47
41
36
32
29
27
24
22

43
36
31
27
24
22
20
18

39
33
27
24
20
18
16
14

45
39
35
31
28
26
24
22

41
35
31
27
24
22
19
17

38
32
27
23
20
18
16
14

37
30
25
22
19
16
15
13

REPORT NUMBER: KPB150LG3_AN
Lamps: 150 W High Pressure Sodium C100S54 ED23 - 1/2 Mogul
Base with G3 Globe and 30° Angle Reflector
COEFFICIENTS OF UTILIZATION - ZONAL CAVITY METHOD

Legend

5 2035 2007 1941 1871 1838 187
15 2375 2307 2140 2047 2037 619

61
55
50
46
42
39
36
34

Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

0-deg
90-deg
180-deg

RC
RW
0
1
2
3
4
5
6
7
8
9
10

70
72
64
57

80
50 30
72 72
60 57
51 46

EFFECTIVE FLOOR CAVITY REFLECTANCE 0.20
70
50
30
10 70 50 30 10 50 30 10 50 30 10
72 70 70 70 70 66 66 66 63 63 63
54 62 58 55 53 55 53 50 52 50 48
42 55 50 45 41 47 43 40 45 41 39

50
60
50
42

10
30
60
48
40

0
10 0
60 58
47 45
37 36

52
47
43
39
36
34
32
30

44
39
34
31
28
25
23
21

34
28
24
20
18
16
14
13

37
32
29
26
24
22
20
18

33
29
25
22
20
18
16
15

31
26
22
19
17
15
13
12

38
33
28
25
22
20
18
16

50
45
41
38
35
33
30
29

43
38
33
30
27
24
22
21

38
32
28
24
22
19
17
16

33
28
24
20
18
16
14
12

41
36
32
28
26
23
21
20

36
31
27
24
21
19
17
15

33
27
23
20
17
15
14
12

39
34
30
27
25
22
21
19

35
30
26
23
20
18
16
15

32
26
22
19
17
15
13
12

29
24
21
18
15
14
12
11

973

Lighting: Enclosed and Gasketed — Area — HID

Candela
488
459

Lighting

Degree
0
5

For candlepower values of fixtures with other
HPS lamps, use the following multipliers: for a
70 W (6,400 lumen) HPS lamp – 0.40; for a 50 W
(4,000 lumen) HPS lamp – 0.25. For candlepower
values of fixture with guard, multiply by 0.95.

Mercmaster™ III HID 50-250 Watt Luminaire Photometric Data
250 W PSMH

Lighting: Enclosed and Gasketed — Area — HID

Lighting

* Photometric data is based on fixtures with a
250-watt clear Pulse Start Metal Halide lamp
(23,000 lumen).

Zone
0-10
10-20

Lumens
307.05
986.27

20-30
30-40
40-50
50-60
60-70
70-80
80-90
90-100
100-110
110-120
120-130
130-140
140-150
150-160
160-170
170-180

1556.63
2215.28
2539.71
2525.66
2313.2
1992.57
1470.76
689.06
177.72
46
10.39
6.24
5.71
3.95
2.26
.8

Zone

Lumens

0-10 382.83
10-20 1200.76
20-30
30-40
40-50
50-60
60-70
70-80
80-90
90-100
100-110
110-120
120-130
130-140
140-150
150-160
160-170
170-180

1987.77
2662.58
3136.15
3436.26
3412.32
1660.08
278.17
3.43
0
0
0
0
0
0
0
0

Candela Distribution

For candlepower values of fixtures with other
PSMH lamps, (21,000 lumen) PSMH lamp – 0.913.
For candlepower values of fixture with guard,
multiply by 0.95.

TOTAL LUMINAIRE EFFICIENCY = 67.4%
CIE Type – Direct
Spacing Criteria: 2.16

ZONAL LUMEN SUMMARY
ZONE
LUMENS %LAMP %FIXT.
0-30                  2849.95 11.4
16.9
0-40 5065.22 20.3
30.1
0-60 10130.59 40.5
60.1
0-90
15907 63.6
94.4
90-120
912.78
3.7
5.4
90-130
923.17
3.7
5.5
90-150
935.11
3.7
5.5
90-180
942.12
3.8
5.6
0-180 16849.24 67.4
100.0
TOTAL LUMINAIRE EFFICIENCY = 72.6%
CIE Type – Direct
Spacing Criteria: 1.58

ZONAL LUMEN SUMMARY
ZONE
LUMENS %LAMP %FIXT.
0-30                  3571.36 14.3
19.7
0-40 6233.94 24.9
34.3
0-60 12806.35 51.2
70.5
0-90 18156.91 72.6
100
90-120
3.43
0
0
90-130
3.43
0
0
90-150
3.43
0
0
90-180
3.43
0
0
0-180 18160.34. 72.6
100.0
TOTAL LUMINAIRE EFFICIENCY = 85.5%

RC
RW
0
1
2
3
4
5
6
7
8
9
10

70
79
70
62
56
51
47
43
40
37
34
32

COEFFICIENTS OF UTILIZATION - ZONAL CAVITY METHOD
EFFECTIVE FLOOR CAVITY REFLECTANCE 0.20
80
70
50
30
10
50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10
79 79 79 77 77 77 77 73 73 73 69 69 69 65 65 65
65 62 58 67 63 60 57 60 57 54 56 54 52 53 51 50
55 50 45 60 54 49 44 51 46 43 48 44 41 45 42 39
48 41 36 54 46 40 36 44 39 34 41 37 33 39 35 32
42 35 30 49 41 34 29 38 33 29 36 31 28 34 30 27
37 30 25 45 36 30 25 34 28 24 32 27 23 30 26 23
33 26 21 41 32 26 21 30 25 21 29 24 20 27 23 20
30 23 19 38 29 23 18 27 22 18 26 21 18 25 20 17
27 21 16 35 26 20 16 25 20 16 24 19 16 23 18 15
24 19 15 33 24 18 14 23 18 14 22 17 14 21 17 14
22 17 13 31 22 17 13 21 16 13 20 16 12 19 15 12

0
0
64
48
38
30
25
21
18
16
14
12
11

REPORT NUMBER: KPBG250PST
Lamps: 250 W Metal Halide Pulse Start
Mogul Base

RC
RW
  0
  1
  2
  3
  4
  5
  6
  7
  8
  9
10

70
86
78
70
63
57
52
48
44
41
38
35

COEFFICIENTS OF UTILIZATION - ZONAL CAVITY METHOD
EFFECTIVE FLOOR CAVITY REFLECTANCE 0.20
80
70
50
30
10
50 30 10 70 50 30 10 50 30 10 50 30 10 50 30
86 86 86 84 84 84 84 81 81 81 77 77 77 74 74
74 71 68 76 73 70 67 70 67 65 67 65 63 64 62
63 58 53 68 62 57 53 59 55 51 57 53 50 55 52
55 48 43 61 53 47 42 51 46 42 49 45 41 47 43
48 41 35 55 47 40 35 45 39 34 43 38 34 41 37
42 35 30 50 41 34 29 39 34 29 38 33 29 37 32
37 30 25 46 37 30 25 35 29 25 34 29 25 33 28
33 27 22 43 33 26 22 32 26 22 31 25 21 30 25
30 24 19 40 30 23 19 29 23 19 28 23 19 27 22
28 21 17 37 27 21 17 26 21 17 25 20 17 25 20
25 19 15 35 25 19 15 24 19 15 23 18 15 23 18

10
74
61
49
40
33
28
24
21
19
17
15

0
0
73
59
47
38
32
27
23
20
17
15
14

REPORT NUMBER: KPBG250PG
Lamps: 250 W Metal Halide Pulse Start
Mogul Base

Zone
0-10

74.54

10-20
20-30
30-40

304.58
486.47
948.61

40-50

1471.61

EFFECTIVE FLOOR CAVITY REFLECTANCE 0.20

50-60
60-70
70-80
80-90

1887.31
2239.17
2561.7
2747.67

RC
80
70
50
30
10
0
RW 70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0
0 94 94 94 94 87 87 87 87 76 76 76 65 65 65 55 55 55 51
1 80 74 68 63 74 68 63 59 58 54 51 49 46 43 40 38 36 31

90-100

2779.02

100-110
110-120
120-130
130-140
140-150
150-160
160-170
170-180

2564.95
2148.15
1109.49
37.55
3.93
.76
.09
.03

974

CIE Type – General Diffuse

REPORT NUMBER: KPBG250PAN
Lamps: 250 W Metal Halide Pulse Start
Mogul Base

COEFFICIENTS OF UTILIZATION - ZONAL CAVITY METHOD

2 71 61 54 47 65 57 50 44 48 42 38 40 36 32 32 29 26 22
ZONAL LUMEN SUMMARY
ZONE
LUMENS %LAMP %FIXT.
0-30
865.59  
3.5
4.1
0-40
1814.2
7.3
8.5
0-60 5173.13 20.7
24.2
0-90 12721.67 50.9
59.5
90-120 7492.124
30
35.1
90-130 8601.61 34.4
40.3
90-150 8643.09 34.6
40.5
90-180 8643.97 34.6
40.5
  0-180 21365.63 85.5
100.0

3
4
5
6
7
8
9
10

63
57
52
47
44
40
37
35

52
45
40
35
31
28
25
23

44
36
31
27
23
20
18
16

37
30
25
21
18
15
13
12

58
52
47
43
40
37
34
32

48
42
36
32
29
26
24
22

41
34
29
25
22
19
17
15

34
28
23
19
16
14
12
11

41
35
31
27
24
22
20
18

34
29
24
21
18
16
14
13

29
24
19
16
14
12
10
9

33
29
25
22
20
18
17
15

29
24
20
17
15
13
12
11

25
20
16
13
11
10
9
8

27
23
20
18
16
15
13
12

23
19
16
14
12
11
10
9

20
16
13
11
9
8
7
6

16
13
10
8
7
6
5
4

Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

Mercmaster™ III HID 50-250 Watt Luminaire Photometric Data
250 W PSMH

Listed for simultaneous exposure to combustible dusts and flammable gases or vapors.
* Photometric data is based on fixtures with a
250-watt clear Pulse Start Metal Halide lamp
(23,000 lumen).

20-30
30-40
40-50
50-60
60-70
70-80
80-90
90-100
100-110
110-120
120-130
130-140
140-150
150-160
160-170
170-180

438.39
727.7
1709.75
2094.28
4828.69
4189.12
2131.34
748.43
1109.54
701.88
410.51
237.73
123.53
37.79
3.51
.32

Zone

Lumens

0-10
10-20

28.96
214.01

20-30

402.91

TOTAL LUMINAIRE EFFICIENCY = 79%
CIE Type – Semi-Direct
Spacing Criteria: 1.64

ZONAL LUMEN SUMMARY
ZONE LUMENS %LAMP %FIXT.
0-30                  689.84
2.8
3.5
0-40 1417.54
5.7
7.2
0-60 5221.56
20.9
26.4
0-90 16370.71
65.5
82.9
90-120 2559.84
10.2
13
90-130 2970.35
11.9
15
90-150 3331.61
13.3
16.9
90-180 3373.23
13.5
17.1
0-180 19743.94
79 100.0
TOTAL LUMINAIRE EFFICIENCY = 84%
CIE Type – Semi-Direct
Spacing Criteria: 1.64

REPORT NUMBER: KPBR250PJ3
Lamps: 250 W Metal Halide Pulse Start
Mogul Base

RC
RW
0
1
2
3
4
5
6
7
8
9
10

70
91
77
66
58
52
47
43
39
36
33
31

COEFFICIENTS OF UTILIZATION - ZONAL CAVITY METHOD
EFFECTIVE FLOOR CAVITY REFLECTANCE 0.20
80
70
50
30
50 30 10 70 50 30 10 50 30 10 50 30 10 50
91 91 91 87 87 87 87 80 80 80 74 74 74 68
70 65 60 73 67 62 57 61 57 53 55 52 49 50
56 48 42 62 54 46 40 48 42 37 43 38 34 39
46 37 30 55 44 36 29 39 32 27 35 29 24 31
39 30 23 49 37 29 22 33 26 20 30 23 18 26
34 25 18 44 32 24 17 29 21 16 25 19 14 22
30 21 15 40 28 20 14 25 18 13 22 16 12 20
26 18 12 37 25 17 12 22 16 11 20 14 9 18
24 16 10 34 22 15 10 20 14 9 18 12 8 16
21 14 9 32 20 13 8 18 12 8 16 11 7 15
19 12 8 29 18 12 7 17 11 7 15 10 6 13

10
30
68
48
35
26
21
17
14
12
11
10
9

10
68
45
31
22
17
13
10
8
7
6
5

0
0
65
42
28
19
14
10
8
6
5
4
4

REPORT NUMBER: KPBR250PJ5
Lamps: 250 W Metal Halide Pulse Start
Mogul Base

30-40

678.83

40-50

1539.03

COEFFICIENTS OF UTILIZATION - ZONAL CAVITY METHOD

50-60
60-70
70-80
80-90
90-100

1537.39
4450.44
5789.28
3160.26
855.15

EFFECTIVE FLOOR CAVITY REFLECTANCE 0.20
RC
80
70
50
30
10
0
RW 70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0
0 97 97 97 97 93 93 93 93 86 86 86 80 80 80 74 74 74 71
1 80 72 66 60 76 69 63 57 63 58 53 57 53 49 52 48 45 42

100-110

1095.13

110-120
120-130
130-140
140-150
150-160
160-170
170-180

596.59
345.11
189.6
82.84
22.91
2.78
.71

ZONAL LUMEN SUMMARY
ZONE LUMENS %LAMP
0-30                  645.89
2.6
0-40 1324.72
5.3
0-60 4401.15
17.6
0-90 17801.14
71.2
90-120 2546.87
10.2
90-130 2891.98
11.6
90-150 3164.41
12.7
90-180 3190.80
12.8
0-180 20991.94
84

%FIXT.
3.1
6.3
21
84.8
12.1
13.8
15.1
15.2
100.0

Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

2 68 57 48 40 65 54 46 38 49 42 35 44 38 33 39 34 30 27
3
4
5
6
7
8
9
10

60
54
48
44
41
38
35
33

47
40
34
30
27
24
22
20

37
29
24
21
18
16
14
12

29
22
17
14
11
10
8
7

56
50
45
41
38
35
33
31

44
37
32
28
25
23
21
19

35
28
23
20
17
15
13
12

27
21
16
13
11
9
8
7

40
33
29
25
23
21
19
17

32
25
21
18
15
14
12
11

25
19
15
12
10
8
7
6

35
30
26
23
20
18
17
16

29
23
19
16
14
12
11
10

23
17
13
11
9
8
7
6

31
26
23
20
18
16
15
14

26
20
17
14
12
11
10
9

21
15
12
10
8
7
6
5

18
13
9
7
6
5
4
3

975

Lighting: Enclosed and Gasketed — Area — HID

Lumens
28.46
222.99

Lighting

Zone
0-10
10-20

For candlepower values of fixtures with other
PSMH lamps, (21,000 lumen) PSMH lamp – 0.913.
For candlepower values of fixture with guard,
multiply by 0.95.

Mercmaster™ III 400 Luminaire for Hazardous and Wet Locations
High Pressure Sodium and Pulse Start Metal Halide

Listed for si­mul­ta­ne­ous ex­po­sure to com­bust­i­ble dusts and flam­ma­ble gas­es or va­pors.
Class I, Division 2, Groups A, B, C, D
Class I, Zone 2, AEx nA nR IIC (Z2)
Class I, Zone 2, Ex nR IIC (Z) V
Class I, Zone 2, AEx nR IIC (ZB)

Class II, Division 1 and 2, Groups E, F, G
Class III
Simultaneous Exposure (Class I, Division 2/
Class II, Division 1)

Fixtures Outside Type (Salt Water)
Type 4X
IP66

Lighting: Enclosed and Gasketed — Area — HID

Lighting

Applications
•	 Enclosed and gasketed fixtures suitable for use in:
— Marine and wet locations
— A wide range of industrial, chemical processing and other areas
where flammable gases and vapors or combustible dusts are
present under conditions defined by the National Electrical
Code as Class I, Division 2; Class II, Division 1 and 2; and
Class III
— In ap­pli­ca­tions in­volv­ing me­di­um and high mount­ing heights
— In ap­pli­ca­tions where en­er­gy ef­fi­cient, high lu­men out­put is
required
— The AEx nA nR Mercmaster III fixture is factory sealed and
prevents vapors and gases from entering the globe chamber.
There are no seals or putty required.
— The AEx nR Mercmaster III fixture requires all wiring entries to
be sealed.
— Non-hazardous locations where severe weather conditions,
excessive moisture, dirt, dust, corrosive atmosphere or high
ambient temperatures are encountered
•	 Typical applications include:
— Pulp and paper mills
— Processing plants
— Chemical plants
— Oil refineries
— Foundries
— Manufacturing plants
— Storage areas
— Waste and sew­age treat­ment
— Oth­er ar­e­as where dust, wa­ter, dirt and rough us­age are a
prob­lem

Features
•	 Superior cor­ro­sion re­sis­tance.
•	 Choice of light sourc­es: high pres­sure so­di­um, and pulse start
metal halide.
•	 Six mount­ing ar­range­ments to suit any light­ing lay­out: pen­dant,
ceil­ing, wall brack­et, 25° (an­gle) stan­chion, 90° (straight) 	
stan­chion and cone.
•	 Hinge has high lip for add­ed safe­ty dur­ing in­stal­la­tion and 	
ser­vic­ing. Hinge and bolt con­struc­tion as­sures 360º com­pres­sion
at all points on bal­last hous­ing gas­ket for pos­i­tive seal­ing. Swing
away de­sign of cap­tive bolt and nut sim­pli­fies ser­vic­ing.
•	 Choice of op­ti­cal as­sem­blies: pris­mat­ic globe; en­closed re­flec­
tor with sealed lens; or Type V or Type II closed pris­mat­ic glass
re­frac­tor, with or with­out guards.
•	 Wide choice of pho­to­met­ric dis­tri­bu­tions.
•	 All fix­tures de­signed to per­form in a 104 ºF/40 ºC am­bi­ent tem­per­
a­ture. Selected fix­tures are suit­a­ble for am­bi­ent tem­per­a­tures up
to 149 ºF/65 ºC.
•	 Mogul base porcelain lamp holder with nickel-plated contacts
has 392 °F/200 °C rated welded leads, pre-wired to the ballast.
Assures trouble-free operation in installations where high ambient
temperatures are encountered.
•	 For electrical protection, a ground wire is provided on each
Mercmaster to bond hood and ballast housing.
•	 Terminal blocks are provided for Zone 2 fixtures to facilitate wiring.
•	 Standard dome of 30º an­gle re­flec­tors made of fi­ber­glass re­in­
forced white poly­es­ter. Highly re­sist­ant to cor­ro­sive at­mos­pheres.
•	 A wide range of voltages available (120 to 600 Volt) and ballast
types (CWA, CWI and Super CWA).

Enclosed Reflector

Prismatic Glass Globe

12” Glass Refractor

•	 One-piece bal­last hous­ing for each com­po­nent pro­vides even
heat dis­si­pa­tion for cool­er op­er­a­tion and long­er bal­last life.
•	 All Mercmaster mount­ing hoods have pro­vi­sion for easy field in­
stal­la­tion of fus­es in fix­tures (see fuse kit list­ings).

Standard Materials
•	 Mounting hoods and bal­last bod­ies: cast copperfree (less than
4/10 of 1% cop­per) alu­mi­num
•	 Reflectors: Fiberglass reinforced white poly­es­ter
•	 Guards, hard­ware and catch as­sem­blies: stain­less steel
•	 Globe: heat- and im­pact-re­sist­ant in­ter­nal­ly flut­ed glass
•	 Refractors: pris­mat­ic glass
•	 Enclosed re­flec­tor: etched Alzak alu­mi­num with sealed, tem­pered
heat- and im­pact-re­sist­ant lens
•	 Body and globe gaskets: high-temperature silicone rubber

Standard Finishes
•	 Mounting hoods and guards: ep­oxy pow­der coat, elec­tro­stat­i­cal­ly
ap­plied for com­plete and uni­form pro­tec­tion

Options
•	 AEx nA nR fixtures are available with a Class I, Zone 2 rating. Add
suffix -Z2.
•	 AEx nR fixtures are available with a Class I, Zone 2 rating. Add
suffix -ZB.
•	 Ex nR fixtures are available with a Class I, Zone 2 rating. Add
suffix -Z V.
•	 Quartz Auxiliary comes to full bright­ness im­me­di­ate­ly and 	
re­mains lit un­til the HID lamp at­tains 60-70% of full il­lu­mi­na­tion.
Quartz Auxiliary sup­plied with re­lay switch and sock­et to ac­cept
120V quartz dou­ble-con­tact bay­o­net base lamp (not in­clud­ed).
(Not suit­a­ble for haz­ard­ous lo­ca­tions.) Add suf­fix -E.
•	 Factory sealed photocontrol available. See PCD2 Series.
•	 Smart Starter incorporates a 1-1/2-minute timer and performs
as a conventional starter to normally start lamp. Removes
itself from circuit if lamp burns out or is removed from socket.
Eliminates starter failures caused by prolonged operation with
cycling or failing lamps and simplifies finding their location,
reducing maintenance and repair costs. Available for all HPS
and PSMH fixtures. Add suffix -S.

Certifications and Compliances
•	 UL Standard: UL 1598, UL 1598A, UL 844, UL 60079-0, UL
60079-15
•	 UL Listed: E10444

V CSA Certification only.

976

Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

Mercmaster™ III 400 Luminaires for Hazardous and Wet Locations
High Pressure Sodium and Pulse Start Metal Halide

Listed for si­mul­ta­ne­ous ex­po­sure to com­bust­i­ble dusts and flam­ma­ble gas­es or va­pors.
Class I, Division 2, Groups A, B, C, D
Class I, Zone 2, AEx nA nR IIC (Z2)
Class I, Zone 2, Ex nR IIC (Z) V
Class I, Zone 2, AEx nR IIC (ZB)

Class II, Division 1 and 2, Groups E, F, G
Class III
Simultaneous Exposure (Class I, Division 2/
Class II, Division 1)

Fixtures Outside Type (Salt Water)
Type 4X
IP66

Illustrated Features

Lighting

High Temperature Sockets
Mogul base high-temperature porcelain
sockets.
Aluminum Inner Reflector
Solid aluminum inner reflector (for
refractor ballast housings only) improves
photometric efficiency.
Globe Chamber
Completely sealed from the ballast
housing and outside vapors/air (nR).

"Safety" High
Hinge
Extra-high hinge
provides additional
protection against
accidental
ballast housing
disengagement
during installation
or maintenance.

Stainless Steel
Latch Assembly
Captive, stainless
steel latch assembly
bolt and nut closes
securely, resists
attack of corrosive
atmospheres.
Swing-away design
simplifies servicing.

Terminal Blocks (Zone 2)
A seven-point terminal block is provided
to facilitate wiring. Terminal block
accommodates wire size ranging from #8
to #24 AWG.
Stainless Steel Inserts
Ballast bodies have stainless steel
threaded inserts to receive stainless steel
screws for reflectors and guard. Prevents
"freezing”, allowing guards and reflectors
to be easily removed and replaced at any
time, without damage to the housing.

Ballast Assembly
Utilizing non-sparking components
avoiding the ignition of gases or vapors
that may be present (nA).
Mounting Hood and Globe Gaskets
Silicone rubber gasket seals out moisture,
dirt and dust. Stays flexible, withstands
high temperatures. Closure design
assures uniform gasket compression.
Electrical Protection
Ground wire provided to bond mounting
hood to ballast housing.

Epoxy Finish
Ballast housing, hoods and guards are
copperfree aluminum with epoxy powder
coat finish.
Photocell
Available for all fixtures except cone and
ceiling mount. Installs through knock-out
in mounting hood. Provides continuous
ON-OFF dusk-to-dawn control.
Prismatic Glass Globes, Refractors
and Enclosed Reflector
Heat-resistant globes, refractors and
enclosed reflector thread into ballast
housing and seal against a high
temperature silicone rubber gasket.

Cooler Operating Cone Hood
Larger sloped surface sheds dusts, dirt
and combustible fibers providing better
heat dissipation.

Fuses
Two screws secure fuse kit to mounting
boss in any Mercmaster mounting hood.
Fuse included.
V CSA Certification only.
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

977

Lighting: Enclosed and Gasketed — Area — HID

Vented Reflectors
Reflectors are thick, tough fiberglass-	
reinforced white polyester, vented for
cooler operation. Quickly attach with
furnished stainless steel screws.

Mercmaster™ III 400 Luminaires for Hazerdous and Wet Locations
High Pressure Sodium and Pulse Start Metal Halide

Listed for si­mul­ta­ne­ous ex­po­sure to com­bust­i­ble dusts and flam­ma­ble gas­es or va­pors.
Class I, Division 2, Groups A, B, C, D
Class I, Zone 2, AEx nA nR IIC (Z2)
Class I, Zone 2, Ex nR IIC (Z) V
Class I, Zone 2, AEx nR IIC (ZB)

Class II, Division 1 and 2, Groups E, F, G
Class III
Simultaneous Exposure (Class I, Division 2/
Class II, Division 1)

Fixtures Outside Type (Salt Water)
Type 4X
IP66

Order using catalog numbering guide below or select catalog number from tables on following pages.
Catalog Numbering Guide

Series:
KP Mercmaster III
400	

Lighting: Enclosed and Gasketed — Area — HID

Lighting

KP

A

L
Lamp Type:
L	 - High Pressure
	 	  Sodium
P	 - Pulse Start     
Metal Halide

Mounting:
A	 - Pendant (rigid
mounting)
C	 - Ceiling
CH	- Pendant Cone Hood
F	 - Pendant (flexible	
mounting)
ST	 - 90° Stanchion
S	 - 25° Stanchion
WB	- Wall

40

10
Hub Size:
75 - 3/4” NPT
10 - 1” NPT
125 - 1-1/4” NPT
stanchion
150 - 1-1/2” NPT
stanchion

J5

G

MT

Guard Options: ➋
G - Globe Guard
BG - Refractor
Guard
NG - Enclosed
Relfector Guard
Blank - No Guard

Wattage:
Optical Assembly: ➊
25 - 250 W HPS, PSMH ➎ Blank - Glass Globe
32 - 320 W PSMH
J2 - NEMA II Glass
35 - 350 W PSMH
Refractor ➍
40 - 400 W PSMH & HPS J5 - NEMA V Glass
40 - 400 W MH V
Refractor ➍
R   - Enclosed Refractor
with Sealed Lens

S

Z2

Options:
E - Emergency Quartz
F - Fuse Kit (Specify
Voltage)
S - Smart Starter
H1 - Photocontrol 120 V
H2 - Photocontrol 208 V
H3 - Photocontrol 240 V
H4 - Photocontrol 277 V
C - Safety Cable
Adapted V
E40 - Export Socket
D - E-40 Export 	
Socket V
T - Terminal Blocks V
V - Anti-Vibration
Modifications V
X - Appledapter ➏
Mounting Hood
Adapter V

Voltage: ➌
MT	 - 120/208/240/277,
60Hz
5MT	 - 120/208/240/
277/480, 60Hz
48	 - 480, 60Hz
125	- 120, 50Hz
226	- 220, 60Hz
235	- 230, 50Hz
245 - 240, 50 Hz
C2 - 208, 60 Hz, CWI V
C3 - 240, 60 Hz, CWI V
C6 - 480, 60 Hz, CWI V
C7 - 600, 60 Hz, CWI V
TT - 120/277/347, 60 Hz,
CWA V

Suffix:
Z2 - Zone 2 suffix
(required for
AEx nA nR
rating)
ZB - Zone 2 suffix
(required for
AEx nR rating)
Z - Zone 2 suffix
(required for 	
Ex nR) V

Refer to “Mounting Hoods and Ballast” page for available Voltage Configuration.
 NO DESIGNATION is required for fixtures with standard type globe.
 NO DESIGNATION is required for fixtures without guards.
➌ Other voltages available. Contact your local sales representative.
➍ J2 and J5 refractions are not available with Z2 or ZB suffix.
➎ Available for 480 V, 50 Hz and 5MT ballast options. For MT and TT voltage suffix, see Mercmaster III 50-250 Luminaries.
➏ Appledapter is available for use with the pendant, ceiling and angled stanchion mounting only.
V CSA Certification only.

978

Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

Mercmaster™ III 400 Luminaire Thermal Performance

Class I, Division 2; Class II, Division 1; Simultaneous Exposure to Hazardous Conditions on Both Classifications
Temperature identification numbers of Mercmaster III – 400 Fixtures.
Class I, Division 2, Groups A, B, C, D
Class I, Zone 2, AEx nA nR IIC (Z2)
Class I, Zone 2, Ex nR IIC (Z) V
Class I, Zone 2, AEx nR IIC (ZB)

Class II, Division 1 and 2, Groups E, F, G
Class III
Simultaneous Exposure (Class I, Division 2/
Class II, Division 1)

Fixtures Outside Type (Salt Water)
Type 4X
IP66

“T” Numbers
Lamp

250

250

HPS
HPS
PSMH

230/110 104/40

T2

T2

T2

T2

T3B

T3B

T4

T4A

325

325

325

325

230/110 131/55

325

325

T2

T2

—

—

T3B

T4A

—

—

T1

325

230/110 149/65

—

—

T2

T2

—

—

T3B

T4

—

—

T1

350

194/90 104/40

350

T3 *

T3 *

T3C

T3C

T1

T1

T1

350

T4

T4A

—

—

—

—

T1

T1

350

194/90 104/40 T2B

T2B

T2B

T2C

194/90 131/55 T2A

T2A

T2B

T2C

—

—

—

—

—

—

—

—

—

—

T2C

—

—

—

—

—

—

—

—

194/90 104/40 T2B

T2B

T2B

T2B

—

—

T3C

T3C

—

—

—

—

194/90 131/55 T2A

T2A

T2A

T2B

—

—

—

—

—

—

—

—

194/90 104/40 T2B

T2B

T2B

T2B

—

—

T3C

T3C

—

—

—

—

194/90 149/65

—

T3 (EF) T3 (EF)

320

PSMH

350

PSMH

194/90 131/55 T2A

T2A

T2A

T2B

—

—

—

—

—

—

—

—

400

PSMH

194/90 104/40 T2A

T2A

T2B

T2B

—

—

T3C

T3C

—

—

—

—

400

MH V

194/90 104/40

T2

T2A

T2A

—

—

T3A

T4

—

—

—

—

T2

“T” Numbers Represent the Maximum Lamp Temperature for Class I, Division 2 Locations and
Maximum Surface Temperature Under Dust Blanket for Class II, Division 1 Locations
“T”
Number

T1

350

325

T2

T2A

T2B

T2C

T2D

T3

T3A

T3B

T3C

T4

T4A

T5

T6

Temp.
Range
(˚ºF)

664842

619662

574617

538572

502536

448500

421446

394419

358392

331356

322329

277320

250275

214248

187212

185

Temp
Range
(ºC)

351450

326350

301325

281300

261280

231260

216230

201215

181200

166180

161165

136160

121135

101120

86100

85

➊ “T” numbers are for Groups E and F only.
V CSA Certification only.
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

979

Lighting: Enclosed and Gasketed — Area — HID

400

Type

Lighting

Watts

Class II, Division 1
Simultaneous Exposure
Supply
Class I, Division 2
Groups E, F and G
Class I, Division 2 / Class II, Division 1
Wire
Ambient
Temp.
Temp.
Globe &
Enclosed
Globe &
Enclosed
Globe &
Enclosed
(°F/°C) ➊ (°F/°C) ➊ Globe Reflector Refractor Reflector Globe Reflector Refractor Reflector Globe Reflector Refractor Reflector

Mercmaster™ III 400 Luminaire Thermal Performance
Class I, Zone 2, AEx nR IIC, AEx nA nR IIC, IP66, NEMA 4X
Temperature identification numbers of Mercmaster III – 400 Fixtures.
Class I, Division 2, Groups A, B, C, D
Class I, Zone 2, AEx nA nR IIC (Z2)
Class I, Zone 2, Ex nR IIC (Z) V
Class I, Zone 2, AEx nR IIC (ZB)

Class II, Division 1 and 2, Groups E, F, G
Class III
Simultaneous Exposure (Class I, Division 2/
Class II, Division 1)

Fixtures Outside Type (Salt Water)
Type 4X
IP66

“T” Numbers

Type

Supply
Wire
Temp.
(°F/°C) ➊

Ambient
Temp.
(°F/°C) ➊

Globe

Globe &
Reflector

Enclosed
Reflector

Globe

Globe &
Reflector

Enclosed
Reflector

HPS

230/110

104/40

T4

T4

T5

T4

T4

T5

HPS

230/110

131/55

T3

T3

T3

T3

T3

T3

HPS

230/110

149/65

—

—

T3

—

—

T3

Lighting

Lamp
Watts
250

Lighting: Enclosed and Gasketed — Area — HID

400
250

320
350

Class 1, Zone 2 AEx nA nR / Ex nR

Class 1, Zone 2 AEx nR

HPS

194/90

104/40

T4

T4

T5

T4

T4

T5

PSMH

194/90

104/40

T3

T3

T3

—

—

—

PSMH

194/90

131/55

T3

T3

T3

—

—

—

PSMH

194/90

104/40

—

—

T3

—

—

—

PSMH

194/90

104/40

T4

T4

T4

T4

T4

T4

PSMH

194/90

131/55

T3

T3

T4

T3

T3

T4

PSMH

194/90

104/40

T4

T4

T4

T4

T4

T4

PSMH

194/90

131/55

T3

T3

T4

T3

T3

T4

400

PSMH

167/75

104/40

T3

T3

T3

T3

T3

T3

400

MH V

167/75

104/40

T3

T3

T3

—

—

—

“T” Numbers represent the maximum surface temperature for luminaries with AEx nA nR and AEx nR rating:
To comply with AEx nR Requirements, all wiring entries must be sealed.

“T”
Number

T1

T2

T3

T4

T5

T6

Temp.
Range (°F)

547-842

394-572

277-392

214-275

187-212

185

Temp.
Range (°C)

301-450

201-300

136-200

101-135

86-100

85

➊ Use 194 °F/90 °C rated supply wire.
V CSA Certification only.

980

Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

Mercmaster™ III 400 Luminaires for Hazerdous and Wet Locations
250 W, 400 W HPS

Listed for si­mul­ta­ne­ous ex­po­sure to com­bust­i­ble dusts and flam­ma­ble gas­es or va­pors.
Class I, Division 2, Groups A, B, C, D
Class I, Zone 2, AEx nA nR IIC (Z2)
Class I, Zone 2, Ex nR IIC (Z) V
Class I, Zone 2, AEx nR IIC (ZB)

Type
Mounting

Class II, Division 1 and 2, Groups E, F, G
Class III
Simultaneous Exposure (Class I, Division 2/
Class II, Division 1)

Lamp
Type

Lamp
Watts

Fixtures Outside Type (Salt Water)
Type 4X
IP66

Hub Size
(Inches)

With Globe

Catalog Numbers ➎
With Type V 12” Refractor 

With Enclosed Reflector

3/4

KPAL2575

KPAL2575J5

KPAL2575R

Pendant — One Hub, Rigid Mounting 

HPS

250
400

KPAL2510

KPAL2510J5

KPAL2510R

KPAL4075

KPAL4075J5

KPAL4075R

1

KPAL4010

KPAL4010J5

KPAL4010R

3/4

KPCHL2575

KPCHL2575J5

KPCHL2575R

Lighting: Enclosed and Gasketed — Area — HID

1
3/4

Lighting

HPS

Shown with Globe
Pendant Cone — One Hub, Rigid Mounting
HPS
HPS

250
400

1

KPCHL2510

KPCHL2510J5

KPCHL2510R

3/4

KPCHL4075

KPCHL4075J5

KPCHL4075R

1

KPCHL4010

KPCHL4010J5

KPCHL4010R

Shown with 12" Glass Refractor
Ceiling — Five Hubs, Four Close-Up Plugs
HPS

250

HPS

400

3/4

KPCL2575

KPCL2575J5

KPCL2575R

1

KPCL2510

KPCL2510J5

KPCL2510R

3/4

KPCL4075

KPCL4075J5

KPCL4075R

1

KPCL4010

KPCL4010J5

KPCL4010R

Shown with Enclosed Reflector

 For Flexible Pendant Mount, change A to F in catalog number.
 To order fixture with NEMA Type II refractor, change digits J5 in catalog number to J2. Refractor not available for Z, Z2 or ZB suffix.
 For fixtures with guards, add suffix G before adding voltage suffix. BG for refractor. NG for enclosed reflector.
➍ Add the following voltage and frequency designations before Z, Z2 or ZB suffix:
Voltage Suffixes
Lamp Type Lamp Watts
MT
5MT
48
125
225
226
235
245
C2 V
C3 V
C6 V
C7 V
TT V
HPS
250
X
X
X
X
—
X
X
—
—
—
—
—
X
HPS
400
X
X
X
X
—
—
X
—
—
—
—
—
X
PSMH
250
—
X
X
X
—
—
X
—
—
—
—
—
—
PSMH
320
X
X
X
X
—
—
X
—
—
—
—
—
X
PSMH
350
X
X
X
X
—
—
X
—
—
—
—
—
X
PSMH
400
X
X
X
—
—
—
X
—
—
—
—
—
X
400
X
—
—
X
X
—
—
X
X
X
X
X
X
MH V
Voltages:
125 - 120 V 50 Hz
245 - 240 V 50 Hz
MT - 120/208/240/277 V 60 Hz
225 - 225 V 50 Hz
C2 - 208 V 60 Hz, CWI V
5MT - 120/208/240/277/480 V 60 Hz
226 - 220 V 60 Hz
C3 - 240 V 60 Hz, CWI V
C7 - 600 V 60 Hz, CWI V,
48 - 480 V 60 Hz
235 - 230 V 50 Hz
C6 - 480 V 60 Hz, CWI V
TT - 120/277/347 V 60 Hz, CWA V

➎ Add Z2 suffix for factory sealed non-sparking/restricted breathing protection (AEx nA nR). Add ZB suffix for restricted breathing protection (AEx nR).
➏ Add Z for factory sealed restricted breathing protection (Ex nR) V.
V CSA Certification only.
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

981

Mercmaster™ III 400 Luminaires for Hazardous and Wet Locations
250 W, 400 W HPS

Listed for si­mul­ta­ne­ous ex­po­sure to com­bust­i­ble dusts and flam­ma­ble gas­es or va­pors.
Class I, Division 2, Groups A, B, C, D
Class I, Zone 2, AEx nA nR IIC (Z2)
Class I, Zone 2, Ex nR IIC (Z) V
Class I, Zone 2, AEx nR IIC (ZB)

Type
Mounting

Class II, Division 1 and 2, Groups E, F, G
Class III
Simultaneous Exposure (Class I, Division 2/
Class II, Division 1)

Lamp
Type

Lamp
Watts

Hub Size
(Inches)

Fixtures Outside Type (Salt Water)
Type 4X
IP66

Catalog Numbers ➎
With Type V 12” Refractor 

With Globe

With Enclosed Reflector

Lighting: Enclosed and Gasketed — Area — HID

Lighting

Wall Five Hubs, Four Close-Up Plugs
HPS

250

HPS

400

HPS

250

3/4

KPWBL2575

KPWBL2575J5

KPWBL2575R

1

KPWBL2510

KPWBL2510J5

KPWBL2510R

3/4
1      

KPWBL4075

KPWBL4075J5

KPWBL4075R

KPWBL4010

KPWBL4010J5

KPWBL4010R

KPSL25125

KPSL25125J5

KPSL25125R

Shown with 12” Glass Refractor
25° Stanchion One Hub

HPS

400

HPS

250

HPS

400

1-1/4
1-1/2

KPSL25150

KPSL25150J5

KPSL25150R

1-1/4

KPSL40125

KPSL40125J5

KPSL40125R

1-1/2

KPSL40150

KPSL40150J5

KPSL40150R

Shown with Prismatic Glass Globe
and Optional Guard
90° Stanchion One Hub
1-1/4

KPSTL25125

KPSTL25125J5

KPSTL25125R

1-1/2

KPSTL25150

KPSTL25150J5

KPSTL25150R

1-1/4

KPSTL40125

KPSTL40125J5

KPSTL40125R

1-1/2

KPSTL40150

KPSTL40150J5

KPSTL40150R

Shown with Prismatic Glass Globe
and Optional Guard
 For Flexible Pendant Mount, change A to F in catalog number.
 To order fixture with NEMA Type II refractor, change digits J5 in catalog number to J2. Refractor not available for Z, Z2 or ZB suffix.
 For fixtures with guards, add suffix G before adding voltage suffix. BG for refractor. NG for enclosed reflector.
➍ Add the following voltage and frequency designations before Z, Z2 or ZB suffix:
Voltage Suffixes
Lamp Type Lamp Watts
MT
5MT
48
125
225
226
235
245
C2 V
C3 V
C6 V
C7 V
TT V
HPS
250
X
X
X
X
—
X
X
—
—
—
—
—
X
HPS
400
X
X
X
X
—
—
X
—
—
—
—
—
X
PSMH
250
—
X
X
X
—
—
X
—
—
—
—
—
—
PSMH
320
X
X
X
X
—
—
X
—
—
—
—
—
X
PSMH
350
X
X
X
X
—
—
X
—
—
—
—
—
X
PSMH
400
X
X
X
—
—
—
X
—
—
—
—
—
X
400
X
—
—
X
X
—
—
X
X
X
X
X
X
MH V
Voltages:
125 - 120 V 50 Hz
245 - 240 V 50 Hz
MT - 120/208/240/277 V 60 Hz
225 - 225 V 50 Hz
C2 - 208 V 60 Hz, CWI V
5MT - 120/208/240/277/480 V 60 Hz
226 - 220 V 60 Hz
C3 - 240 V 60 Hz, CWI V
C7 - 600 V 60 Hz, CWI V,
48 - 480 V 60 Hz
235 - 230 V 50 Hz
C6 - 480 V 60 Hz, CWI V
TT - 120/277/347 V 60 Hz, CWA V

➎ Add Z2 suffix for factory sealed non-sparking/restricted breathing protection (AEx nA nR). Add ZB suffix for restricted breathing protection (AEx nR).
➏ Add Z for factory sealed restricted breathing protection (Ex nR) V.
V CSA Certification only.

982

Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

Mercmaster™ III 400 Luminaires for Hazardous and Wet Locations
250 W, 320 W, 350 W, 400 W PSMH

Listed for si­mul­ta­ne­ous ex­po­sure to com­bust­i­ble dusts and flam­ma­ble gas­es or va­pors.
Class I, Division 2, Groups A, B, C, D
Class I, Zone 2, AEx nA nR IIC (Z2)
Class I, Zone 2, Ex nR IIC (Z) V
Class I, Zone 2, AEx nR IIC (ZB)

Type
Mounting

Class II, Division 1 and 2, Groups E, F, G
Class III
Simultaneous Exposure (Class I, Division 2/
Class II, Division 1)

Lamp
Type

Lamp
Watts

Hub Size
(Inches)

With Globe

Fixtures Outside Type (Salt Water)
Type 4X
IP66

Catalog Numbers ➎
With Type V 12” Refractor 

With Enclosed Reflector

Pendant One Hub, Rigid Mounting 

PSMH

320

PSMH

350

PSMH

400

3/4

KPAP2575

KPAP2575J5

KPAP2575R

1

KPAP2510

KPAP2510J5

KPAP2510R

3/4

KPAP3275

KPAP3275J5

KPAP3275R

1

KPAP3210

KPAP3210J5

KPAP3210R

3/4

KPAP3575

KPAP3575J5

KPAP3575R

1

KPAP3510

KPAP3510J5

KPAP3510R

3/4

KPAP4075

KPAP4075J5

KPAP4075R

1

KPAP4010

KPAP4010J5

KPAP4010R

3/4

KPCHP2575

KPCHP2575J5

KPCHP2575R

1

KPCHP2510

KPCHP2510J5

KPCHP2510R

3/4

KPCHP3275

KPCHP3275J5

KPCHP3275R

1

KPCHP3210

KPCHP3210J5

KPCHP3210R

3/4

KPCHP3575

KPCHP3575J5

KPCHP3575R

1

KPCHP3510

KPCHP3510J5

KPCHP3510R

3/4

KPCHP4075

KPCHP4075J5

KPCHP4075R

1

KPCHP4010

KPCHP4010J5

KPCHP4010R

3/4

KPCP2575

KPCP2575J5

KPCP2575R

1

KPCP2510

KPCP2510J5

KPCP2510R

3/4

KPCP3275

KPCP3275J5

KPCP3275R

1

KPCP3210

KPCP3210J5

KPCP3210R

3/4

KPCP3575

KPCP3575J5

KPCP3575R

1

KPCP3510

KPCP3510J5

KPCP3510R

3/4

KPCP4075

KPCP4075J5

KPCP4075R

1

KPCP4010

KPCP4010J5

KPCP4010R

Lighting: Enclosed and Gasketed — Area — HID

Shown with Globe

250 ➐

Lighting

PSMH

Pendant Cone One Hub, Rigid Mounting
PSMH
PSMH
PSMH
Shown with 12" Glass Refractor

PSMH

250 ➐
320
350
400

Ceiling Five Hubs, Four Close-Up Plugs
PSMH
PSMH
PSMH

Shown with Enclosed Refractor

PSMH

250 ➐
320
350
400

 For Flexible Pendant Mount, change A to F in catalog number.
 To order fixture with NEMA Type II refractor, change digits J5 in catalog number to J2. Refractor not available for Z, Z2 or ZB suffix.
 For fixtures with guards, add suffix G before adding voltage suffix. BG for refractor. NG for enclosed reflector.
➍ Add the following voltage and frequency designations before Z, Z2 or ZB suffix:
Voltage Suffixes
Lamp Type Lamp Watts
MT
5MT
48
125
225
226
235
245
C2 V
C3 V
C6 V
C7 V
TT V
HPS
250
X
X
X
X
—
X
X
—
—
—
—
—
X
HPS
400
X
X
X
X
—
—
X
—
—
—
—
—
X
PSMH
250
—
X
X
X
—
—
X
—
—
—
—
—
—
PSMH
320
X
X
X
X
—
—
X
—
—
—
—
—
X
PSMH
350
X
X
X
X
—
—
X
—
—
—
—
—
X
PSMH
400
X
X
X
—
—
—
X
—
—
—
—
—
X
400
X
—
—
X
X
—
—
X
X
X
X
X
X
MH V
Voltages:
125 - 120 V 50 Hz
245 - 240 V 50 Hz
MT - 120/208/240/277 V 60 Hz
225 - 225 V 50 Hz
C2 - 208 V 60 Hz, CWI V
5MT - 120/208/240/277/480 V 60 Hz
226 - 220 V 60 Hz
C3 - 240 V 60 Hz, CWI V
C7 - 600 V 60 Hz, CWI V,
48 - 480 V 60 Hz
235 - 230 V 50 Hz
C6 - 480 V 60 Hz, CWI V
TT - 120/277/347 V 60 Hz, CWA V

➎ Add Z2 suffix for factory sealed non-sparking/restricted breathing protection (AEx nA nR). Add ZB suffix for restricted breathing protection (AEx nR).
➏ Add Z for factory sealed restricted breathing protection (Ex nR) V.
V CSA Certification only.
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

983

Mercmaster™ III 400 Luminaires for Hazardous and Wet Locations
250 W, 320 W, 350 W, 400 W PSMH

Listed for si­mul­ta­ne­ous ex­po­sure to com­bust­i­ble dusts and flam­ma­ble gas­es or va­pors.
Class I, Division 2, Groups A, B, C, D
Class I, Zone 2, AEx nA nR IIC (Z2)
Class I, Zone 2, Ex nR IIC (Z) V
Class I, Zone 2, AEx nR IIC (ZB)

Type
Mounting

Class II, Division 1 and 2, Groups E, F, G
Class III
Simultaneous Exposure (Class I, Division 2/
Class II, Division 1)

Lamp
Type

Lamp
Watts

Fixtures Outside Type (Salt Water)
Type 4X
IP66

Hub Size
(Inches)

With Globe

Catalog Numbers ➎
With Type V 12” Refractor 

With Enclosed Reflector

3/4

KPWBP2575

KPWBP2575J5

KPWBP2575R

1

KPWBP2510

KPWBP2510J5

KPWBP2510R

3/4

KPWBP3275

KPWBP3275J5

KPWBP3275R

KPWBP3210

KPWBP3210J5

KPWBP3210R

KPWBP3575

KPWBP3575J5

KPWBP3575R

KPWBP3510

KPWBP3510J5

KPWBP3510R

KPWBP4075

KPWBP4075J5

KPWBP4075R

KPWBP4010

KPWBP4010J5

KPWBP4010R

1-1/4

KPSP25125

KPSP25125J5

KPSP25125R

1-1/2

KPSP25150

KPSP25150J5

KPSP25150R

1-1/4

KPSP32125

KPSP32125J5

KPSP32125R

1-1/2

KPSP32150

KPSP32150J5

KPSP32150R

1-1/4

KPSP35125

KPSP35125J5

KPSP35125R

1-1/2

KPSP35150

KPSP35150J5

KPSP35150R

1-1/4

KPSP40125

KPSP40125J5

KPSP40125R

1-1/2

KPSP40150

KPSP40150J5

KPSP40150R

1-1/4

KPSTP25125

KPSTP25125J5

KPSTP25125R

1-1/2

KPSTP25150

KPSTP25150J5

KPSTP25150R

1-1/4

KPSTP32125

KPSTP32125J5

KPSTP32125R

1-1/2

KPSTP32150

KPSTP32150J5

KPSTP32150R

1-1/4

KPSTP35125

KPSTP35125J5

KPSTP35125R

1-1/2

KPSTP35150

KPSTP35150J5

KPSTP35150R

1-1/4

KPSTP40125

KPSTP40125J5

KPSTP40125R

1-1/2

KPSTP40150

KPSTP40150J5

KPSTP40150R

Lighting

Wall Five Hubs, Four Close-Up Plugs
PSMH
PSMH

Lighting: Enclosed and Gasketed — Area — HID

PSMH
Shown with 12” Glass Refractor

250 ➐
320
350

PSMH

400

PSMH

250 ➐

PSMH

320

1      
3/4
1      
3/4
1      

25° Stanchion One Hub

PSMH
Shown with Prismatic Glass Globe
and Optional Guard

350

PSMH

400

PSMH

250 ➐

90° Stanchion One Hub

PSMH

Shown with Prismatic Glass Globe
and Optional Guard

320

PSMH

350

PSMH

400

 For Flexible Pendant Mount, change A to F in catalog number.
 To order fixture with NEMA Type II refractor, change digits J5 in catalog number to J2. Refractor not available for Z, Z2 or ZB suffix.
 For fixtures with guards, add suffix G before adding voltage suffix. BG for refractor. NG for enclosed reflector.
➍ Add the following voltage and frequency designations before Z, Z2 or ZB suffix:
Voltage Suffixes
Lamp Type Lamp Watts
MT
5MT
48
125
225
226
235
245
C2 V
C3 V
C6 V
C7 V
TT V
HPS
250
X
X
X
X
—
X
X
—
—
—
—
—
X
HPS
400
X
X
X
X
—
—
X
—
—
—
—
—
X
PSMH
250
—
X
X
X
—
—
X
—
—
—
—
—
—
PSMH
320
X
X
X
X
—
—
X
—
—
—
—
—
X
PSMH
350
X
X
X
X
—
—
X
—
—
—
—
—
X
PSMH
400
X
X
X
—
—
—
X
—
—
—
—
—
X
400
X
—
—
X
X
—
—
X
X
X
X
X
X
MH V
Voltages:
125 - 120 V 50 Hz
245 - 240 V 50 Hz
MT - 120/208/240/277 V 60 Hz
225 - 225 V 50 Hz
C2 - 208 V 60 Hz, CWI V
5MT - 120/208/240/277/480 V 60 Hz
226 - 220 V 60 Hz
C3 - 240 V 60 Hz, CWI V
C7 - 600 V 60 Hz, CWI V,
48 - 480 V 60 Hz
235 - 230 V 50 Hz
C6 - 480 V 60 Hz, CWI V
TT - 120/277/347 V 60 Hz, CWA V

➎ Add Z2 suffix for factory sealed non-sparking/restricted breathing protection (AEx nA nR). Add ZB suffix for restricted breathing protection (AEx nR).
➏ Add Z for factory sealed restricted breathing protection (Ex nR) V.
V CSA Certification only.

984

Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

Mercmaster™ III 400 Luminaires for Hazardous and Wet Locations
400 W MH V

Listed for si­mul­ta­ne­ous ex­po­sure to com­bust­i­ble dusts and flam­ma­ble gas­es or va­pors.
Class I, Division 2, Groups A, B, C, D
Class I, Zone 2, AEx nA nR IIC (Z2)
Class I, Zone 2, Ex nR IIC (Z) V
Class I, Zone 2, AEx nR IIC (ZB)

Type
Mounting

Class II, Division 1 and 2, Groups E, F, G
Class III
Simultaneous Exposure (Class I, Division 2/
Class II, Division 1)

Lamp
Type

Lamp
Watts

Hub Size
(Inches)

With Globe

Fixtures Outside Type (Salt Water)
Type 4X
IP66

Catalog Numbers ➎
With Type V 12” Refractor 

With Enclosed Reflector

Pendant One Hub, Rigid Mounting 

400

KPAH4075

KPAH4075J5

KPAH4075R

1

KPAH4010

KPAH4010J5

KPAH4010R

3/4

KPCHH4075

KPCHH4075J5

KPCHH4075R

1

KPCHH4010

KPCHH4010J5

KPCHH4010R

3/4

KPCH4075

KPCH4075J5

KPCH4075R

1

KPCH4010

KPCH4010J5

KPCH4010R

Lighting: Enclosed and Gasketed — Area — HID

3/4

Lighting

MH V

Shown with Globe
Pendant Cone One Hub, Rigid Mounting

MH V

400

Shown with 12" Glass Refractor
Ceiling Five Hubs, Four Close-Up Plugs

MH V

400

Shown with Enclosed Refractor
 For Flexible Pendant Mount, change A to F in catalog number.
 To order fixture with NEMA Type II refractor, change digits J5 in catalog number to J2. Refractor not available for Z, Z2 or ZB suffix.
 For fixtures with guards, add suffix G before adding voltage suffix. BG for refractor. NG for enclosed reflector.
➍ Add the following voltage and frequency designations before Z, Z2 or ZB suffix:
Voltage Suffixes
Lamp Type Lamp Watts
MT
5MT
48
125
225
226
235
245
C2 V
C3 V
C6 V
C7 V
TT V
HPS
250
X
X
X
X
—
X
X
—
—
—
—
—
X
HPS
400
X
X
X
X
—
—
X
—
—
—
—
—
X
PSMH
250
—
X
X
X
—
—
X
—
—
—
—
—
—
PSMH
320
X
X
X
X
—
—
X
—
—
—
—
—
X
PSMH
350
X
X
X
X
—
—
X
—
—
—
—
—
X
PSMH
400
X
X
X
—
—
—
X
—
—
—
—
—
X
400
X
—
—
X
X
—
—
X
X
X
X
X
X
MH V
Voltages:
125 - 120 V 50 Hz
245 - 240 V 50 Hz
MT - 120/208/240/277 V 60 Hz
225 - 225 V 50 Hz
C2 - 208 V 60 Hz, CWI V
5MT - 120/208/240/277/480 V 60 Hz
226 - 220 V 60 Hz
C3 - 240 V 60 Hz, CWI V
C7 - 600 V 60 Hz, CWI V,
48 - 480 V 60 Hz
235 - 230 V 50 Hz
C6 - 480 V 60 Hz, CWI V
TT - 120/277/347 V 60 Hz, CWA V

➎ Add Z2 suffix for factory sealed non-sparking/restricted breathing protection (AEx nA nR). Add ZB suffix for restricted breathing protection (AEx nR).
➏ Add Z for factory sealed restricted breathing protection (Ex nR) V.
➐ Available for 480 V, 50 Hz and 5MT ballast options. For MT and TT voltage suffix, see Mercmaster III 50-250 Luminaries.
V CSA Certification only.

Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

985

Mercmaster™ III 400 Luminaires for Hazardous and Wet Locations
400 W MH V

Listed for si­mul­ta­ne­ous ex­po­sure to com­bust­i­ble dusts and flam­ma­ble gas­es or va­pors.
Class I, Division 2, Groups A, B, C, D
Class I, Zone 2, AEx nA nR IIC (Z2)
Class I, Zone 2, Ex nR IIC (Z) V
Class I, Zone 2, AEx nR IIC (ZB)

Type
Mounting

Class II, Division 1 and 2, Groups E, F, G
Class III
Simultaneous Exposure (Class I, Division 2/
Class II, Division 1)

Lamp
Type

Lamp
Watts

Fixtures Outside Type (Salt Water)
Type 4X
IP66

Hub Size
(Inches)

With Globe

Catalog Numbers ➎
With Type V 12” Refractor 

With Enclosed Reflector

3/4

KPWBH4075

KPWBH4075J5

KPWBH4075R

KPWBH4010

KPWBH4010J5

KPWBH4010R

1-1/4

KPSH40125

KPSH40125J5

KPSH40125R

1-1/2

KPSH40150

KPSH40150J5

KPSH40150R

1-1/4

KPSTH40125

KPSTH40125J5

KPSTH40125R

1-1/2

KPSTH40150

KPSTH40150J5

KPSTH40150R

Lighting: Enclosed and Gasketed — Area — HID

Lighting

Wall Five Hubs, Four Close-Up Plugs

MH V

400

MH V

400

MH V

400

1      

Shown with 12” Glass Refractor
25° Stanchion One Hub

Shown with Prismatic Glass Globe
and Optional Guard
90° Stanchion One Hub

Shown with Prismatic Glass Globe
and Optional Guard
 For Flexible Pendant Mount, change A to F in catalog number.
 To order fixture with NEMA Type II refractor, change digits J5 in catalog number to J2. Refractor not available for Z, Z2 or ZB suffix.
 For fixtures with guards, add suffix G before adding voltage suffix. BG for refractor. NG for enclosed reflector.
➍ Add the following voltage and frequency designations before Z, Z2 or ZB suffix:
Voltage Suffixes
Lamp Type Lamp Watts
MT
5MT
48
125
225
226
235
245
C2 V
C3 V
C6 V
C7 V
TT V
HPS
250
X
X
X
X
—
X
X
—
—
—
—
—
X
HPS
400
X
X
X
X
—
—
X
—
—
—
—
—
X
PSMH
250
—
X
X
X
—
—
X
—
—
—
—
—
—
PSMH
320
X
X
X
X
—
—
X
—
—
—
—
—
X
PSMH
350
X
X
X
X
—
—
X
—
—
—
—
—
X
PSMH
400
X
X
X
—
—
—
X
—
—
—
—
—
X
400
X
—
—
X
X
—
—
X
X
X
X
X
X
MH V
Voltages:
125 - 120 V 50 Hz
245 - 240 V 50 Hz
MT - 120/208/240/277 V 60 Hz
225 - 225 V 50 Hz
C2 - 208 V 60 Hz, CWI V
5MT - 120/208/240/277/480 V 60 Hz
226 - 220 V 60 Hz
C3 - 240 V 60 Hz, CWI V
C7 - 600 V 60 Hz, CWI V,
48 - 480 V 60 Hz
235 - 230 V 50 Hz
C6 - 480 V 60 Hz, CWI V
TT - 120/277/347 V 60 Hz, CWA V

➎ Add Z2 suffix for factory sealed non-sparking/restricted breathing protection (AEx nA nR). Add ZB suffix for restricted breathing protection (AEx nR).
➏ Add Z for factory sealed restricted breathing protection (Ex nR) V.
V CSA Certification only.

986

Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

Mercmaster™ III 400 Luminaire Mounting Hood and Ballast Bodies

High Pressure Sodium and Pulse Start Metal Halide - Hazardous and Wet Locations
Listed for si­mul­ta­ne­ous ex­po­sure to com­bust­i­ble dusts and flam­ma­ble gas­es or va­pors.
Class I, Division 2, Groups A, B, C, D
Class I, Zone 2, AEx nA nR IIC (Z2)
Class I, Zone 2, Ex nR IIC (Z) V
Class I, Zone 2, AEx nR IIC (ZB)

Class II, Division 1 and 2, Groups E, F, G
Class III
Simultaneous Exposure (Class I, Division 2/
Class II, Division 1)

Fixtures Outside Type (Salt Water)
Type 4X
IP66

Mounting Hoods
Description

Hub Size (Inches)

Catalog Number

Pendant
3/4

KPA-75

1

KPA-100

3/4

KPAF-75

1

KPAF-100

3/4

KPCH-75

1

KPCH-100

Lighting

One Hub, Rigid Mounting
Pendant — Flexible
One Hub, Flexible Mounting
Pendant Cone

Ceiling
Five Hubs, Four Close-Up Plugs

3/4

KPC-75

1

KPC-100

3/4

KPWB-75

1

KPWB-100

Wall
Five Hubs, Four Close-Up Plugs
25° Stanchion
One Hub

1-1/4

KPS-125

1-1/2

KPS-150

1-1/4

KPST-125

1-1/2

KPST-150

90° Stanchion
One Hub

Ballast Bodies
High Pressure Sodium — Constant Wattage (Min. P.F. 90%)
Pulse Start Metal Halide — Super Constant Wattage (Min. P.F. 90%)
Lamp
Type
HPS
HPS
PSMH
PSMH
PSMH
PSMH
MH V

Lamp
Watts
250
400
250
320
350
400
400

Catalog
Numbers ➋➍
KPB250L ➊➌
KPB400L ➊➌
KPB250P ➊➌
KPB320P ➊➌
KPB350P ➊➌
KPB400P ➊➌
KPB400H

Voltages:
MT - 120/208/240/277 V 60 Hz
5MT - 120/208/240/277/480 V 60 Hz
48 - 480 V 60 Hz

MT
X
X
—
X
X
X
X

5MT
X
X
X
X
X
X
—

48
X
X
X
X
X
X
—

125 - 120 V 50 Hz
225 - 225 V 50 Hz
226 - 220 V 60 Hz
235 - 230 V 50 Hz

125
X
X
X
X
X
—
X

225
—
—
—
—
—
—
X

Voltage Suffixes
226
235
245
X
X
—
—
X
—
—
X
—
—
X
—
—
X
—
—
X
—
—
—
X

245 - 240 V 50 Hz
C2 - 208 V 60 Hz, CWI V
C3 - 240 V 60 Hz, CWI V
C6 - 480 V 60 Hz, CWI V  

C2 V
—
—
—
—
—
—
X

C3 V
—
—
—
—
—
—
X

C6 V
—
—
—
—
—
—
X

C7 V
—
—
—
—
—
—
X

TT V
X
X
X
X
X
X
X

C7 - 600 V 60 Hz, CWI V,
TT - 120/277/347 V 60 Hz, CWA V

➊ Add -S after voltage designation for ballast body with Smart Starter (HPS and PSMH only).
➋ Add -E after voltage designation for ballast body with provision for Quartz Emergency Light (not suitable for hazardous location).
➌ Add Z2 suffix for factory sealed non-sparking/restricted breathing protection (AEx nA nR). Add ZB suffix for restricted breathing protection (AEx nR).
➍ Add Z for factory sealed restricted breathing protection (Ex nR) V.
V CSA Certification only.
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

987

Lighting: Enclosed and Gasketed — Area — HID

One Hub, Rigid

Mercmaster™ III 400 Luminaire Optics and Accessories

High Pressure Sodium and Pulse Start Metal Halide - Hazardous and Wet Locations
Listed for si­mul­ta­ne­ous ex­po­sure to com­bust­i­ble dusts and flam­ma­ble gas­es or va­pors.

Description

Catalog Number

Lighting

Prismatic Glass Globes — Heat-Resistant

Clear

VPGL-4HR

Heat- and impact-resistant glass lens

KPR-4HB

Glass Globe

Lighting: Enclosed and Gasketed — Area — HID

Enclosed Reflector Assembly

Enclosed Reflector
Light Distribution

IES/NEMA Distribution Curves

Catalog Number

Closed Prismatic Glass Refractors ➌ — All Heat-Resistant
NEMA Type II

KPRF400-2

NEMA Type V

KPRF400-5

Glass Refractor
Item

Description

Catalog Number

White Polyester Reflectors Furnished with stainless steel screws
For use with globe fixtures

Standard and Deep Dome

Standard Dome

CMR4-ST ➊

30° Angle

CMR4-AN

Deep Dome

CMR4-DD ➊➋

Globe Guard

KPGU400

Refractor Guard

KPBG12

Enclosed Reflector Guard

GHB7000-NG

30° Angle

Guards

Globe Guard

Refractor Guard

Enclosed Reflector Guard
➊ Contact your local sales representative if used with KPWB or KPST mounting hoods.
➋ Complies Dark Skies.
➌ Not suitable for use with Z, Z2 or ZB suffixes (Zone 2).

988

Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

Mercmaster™ III 400 Luminaire Electrical Specifications and Fuse Kits
High Pressure Sodium and Pulse Start Metal Halide - Hazardous and Wet Locations
Listed for si­mul­ta­ne­ous ex­po­sure to com­bust­i­ble dusts and flam­ma­ble gas­es or va­pors.
Class I, Division 2, Groups A, B, C, D
Class I, Zone 2, AEx nA nR IIC (Z2)
Class I, Zone 2, Ex nR IIC (Z) V
Class I, Zone 2, AEx nR IIC (ZB)

Class II, Division 1 and 2, Groups E, F, G
Class III
Simultaneous Exposure (Class I, Division 2/
Class II, Division 1)

Electrical Specifications

Electrical Specifications
Operating
Amps

Total
Watts

2.00
1.20
1.00
0.85
0.60
0.40
1.85
0.95

2.50
1.50
1.30
1.10
0.93
0.65
2.75
1.44

295
295
295
295
295
295
300
300

3.30
1.80
1.60
1.40
1.00
0.80
3.70
1.85

3.80
2.20
1.90
1.70
1.32
1.00
4.00
2.00

465
465
465
465
464
465
465
465

1.96
1.13
0.98
0.85
0.62
0.32
0.45
1.90
1.00

2.50
1.45
1.25
1.10
0.90
0.69
0.60
2.60
1.35

291
291
291
291
291
298
285
288
288

2.60
1.50
1.30
1.15
0.70
0.60
2.28
1.14

3.25
1.90
1.65
1.40
1.10
0.80
3.05
1.60

368
368
368
368
368
368
365
365

3.30
1.90
1.65
1.40
0.85
0.75
2.45
1.26

3.60
2.10
1.80
1.55
1.20
0.90
3.34
1.74

400
400
400
400
400
400
394
394

3.50
2.00
1.75
1.50
1.10
0.90
3.17
1.65

4.00
2.30
2.00
1.25
1.35
1.00
3.90
2.00

454
454
454
454
452
454
454
454

Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

Line
Type of
Voltage
Ballast ➊
Frequency
400 Watt Metal Halide V
120
C.W.A.
60
208
C.W.A.
60
240
C.W.A.
60
277
C.W.A.
60
347
C.W.A.
60
480
C.W.I.
60
600
C.W.I.
60
120
C.W.A.
50
220
C.W.A.
50
240
C.W.A.
50

Starting
Amps

Operating
Amps

Total
Watts

3.25
1.90
1.80
1.70
1.40
0.85
0.30
2.70
1.50
1.50

4.00
2.30
2.00
1.75
1.75
1.00
0.70
4.10
2.10
2.10

458
458
458
458
458
462
475
462
462
462

Fuse Kit

Order fuses as a separate item by catalog number from right columns.

Lamp
Watts

250

250

320

350

400

Volts
120
208
240
277
347V
480
120
230
480
230
120
208
240
277
347V
480
120
230
120
208
240
277
347V
480
120
230
120
208
240
277
347V
480
120
230

Fuse
Quantity
Required
1
2
2
1
1
2
1
2
2
1
1
2
2
1
1
2
1
2
1
2
2
1
1
2
1
2
1
2
2
1
1
2
1
2

Fuse Catalog Number
HPS
F7
F4
F4
F3
F3
F2
F7
F4
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
F15
F8
F8
F5
F5
F5
F10
F6

PSMH
—
—
—
—
F3
—
—
—
F2
F3
F9
F6
F5
F4
F3
F3
F10
F5
F10
F7
F5
F5
F3
F3
F10
F5
F10
F7
F5
F5
F5
F3
F10
F5

MH V
—
—
—
—
F3
—
—
—
—
—
—
—
—
—
F3
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
F5
—
—
—

➊ C.W.A. – Constant Wattage Autotransformer. HX-HPF – High Reactance
High Power Factor Autotransformer.
Super C.W.A. – Super Constant Wattage Autotransformer.
V CSA Certification only.

989

Lighting: Enclosed and Gasketed — Area — HID

Starting
Amps

Lighting

Line
Type of
Voltage
Ballast ➊
Frequency
250 Watt High Pressure Sodium
120
C.W.A.
60
208
C.W.A.
60
240
C.W.A.
60
277
C.W.A.
60
C.W.A.
60
347V
480
C.W.A.
60
120
C.W.A.
50
230
C.W.A.
50
400 Watt High Pressure Sodium
120
C.W.A.
60
208
C.W.A.
60
240
C.W.A.
60
277
C.W.A.
60
C.W.A.
60
347V
480
C.W.A.
60
120
C.W.A.
50
230
C.W.A.
50
250 Watt Pulse Start Metal Halide
120
C.W.A.
60
208
C.W.A.
60
240
C.W.A.
60
277
C.W.A.
60
C.W.A.
60
347V
480
C.W.A.
60
480
Super C.W.A.
60
120
Super C.W.A.
50
230
Super C.W.A.
50
320 Watt Pulse Start Metal Halide
120
Super C.W.A.
60
208
Super C.W.A.
60
240
Super C.W.A.
60
277
Super C.W.A.
60
Super C.W.A.
60
347V
480
Super C.W.A.
60
120
Super C.W.A.
50
230
Super C.W.A.
50
350 Watt Pulse Start Metal Halide
120
Super C.W.A.
60
208
Super C.W.A.
60
240
Super C.W.A.
60
277
Super C.W.A.
60
Super C.W.A.
60
347V
480
Super C.W.A.
60
120
Super C.W.A.
50
230
Super C.W.A.
50
400 Watt Pulse Start Metal Halide
120
Super C.W.A.
60
208
Super C.W.A.
60
240
Super C.W.A.
60
277
Super C.W.A.
60
Super C.W.A.
60
347V
480
Super C.W.A.
60
120
Super C.W.A.
50
230
Super C.W.A.
50

Fixtures Outside Type (Salt Water)
Type 4X
IP66

Mercmaster™ III 400 Luminaire Dimensions and Weights

High Pressure Sodium and Pulse Start Metal Halide - Hazardous and Wet Locations
Listed for si­mul­ta­ne­ous ex­po­sure to com­bust­i­ble dusts and flam­ma­ble gas­es or va­pors.

Wall

Lighting: Enclosed and Gasketed — Area — HID

Lighting

Pendant with Globe,
Guard and Reflectors

25° Stanchion

Cone

Ceiling with Refractor
Enclosed Reflector and Guards

90° Stanchion

Deep Dome

Mercmaster III – 400 Ballast and Accessory Weights
Lamp Watts

Ballast Housing (Wt. Lbs/Kg)
HPS
PSMH

250

24.5/11.1

—

320

—

28.0/12.7

350

—

28.5/12.9

400

28.5/12.9

28.5/12.9

Mounting Hoods
and Reflectors
Pendant
Pendant Cone
Ceiling
Wall
25° Stanchion
90° Stanchion
Standard Dome
30° Angle

Wt. Lbs.
2.25/1.0
2.50/1.1
3.00/1.4
4.00/1.8
3.25/1.5
3.75/1.7
3.50/1.6
3.50/1.6

Globe Refractor, Enclosed
Reflector and Guards
Glass Globe
Globe Guard
12” Glass Refractor
Refractor Guard
Enclosed Reflector
Enclosed Reflector Guard

Wt. Lbs/Kg
7.0/3.2
3.0/1.4
12.0/5.4
4.5/2.0
11.0/5.0
2.0/0.9

Weights are approximate. Add 0.25 lb. for Quartz option.

990

Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

PCD2 Series Factory Sealed Hazardous Location Photocontrol
For use in Class I, Division 2, Groups A, B, C, D locations

Maintains Class I, Division 2 rating for Mercmaster III – Low Profile, Mercmaster III, and Mercmaster III – 400 Series Luminaires, Mercmaster LED
Class I, Division 2, Groups A, B, C, D
NEMA 4X

Applications

Materials

•	 Encapsulated photocontrol provides automatic dusk-to-dawn
lighting control in Class I, Division 2 locations.
•	 Typical applications include walkways, security areas and any
other outdoor lighting application.
•	 For use with Mercmaster III – Low Profile, Mercmaster III, and
Mercmaster III – 400 Series Luminaires.
•	 For remote mounting in FS Boxes.

•	 Encapsulated with epoxy sealing compound
•	 FS: aluminum
Lighting

Certifications and Compliances
•	 UL Standard: 1604 ­– Hazardous (Classified) Locations
•	 cULus Recognized

Features

Factory-Installed Photocontrol

Dimensions

Add to fixture catalog after voltage; i.e.: KPWBL1075MTH1.

Mercmaster III wall mounting hood
with photocontrol installed shown

Lighting: Enclosed and Gasketed — Area — HID

•	 Factory sealed design eliminates the need for an explosionproof
enclosure.
•	 Can be easily installed in the field.
•	 Solid state design for performance and reliability.
•	 Available for 120, 208, 240, or 277 volts.
•	 50-400 W HID, incandescent or fluorescent, 50/60 Hz.
•	 1000 VA Voltage/Ampere
•	 Minimum time delay: 15 seconds to eliminate nuisiance tripping.
•	 Provided with (3) 18AWG stranded leads 6”/152.4 mm in length.
•	 Will fit through standard 1/2” knockout.

Voltage Range

Suffix Designation

120 V, 50/60 Hz

H1

208 V, 50/60 Hz

H2

240 V, 50/60 Hz

H3

277 V, 50/60 Hz

H4
1.13”
28.7
mm
1.13”
28.7 mm

Photocontrol in FS Cover for Use with FS/FD Box

Supplied with two stainless steel screws. For neoprene gasket, order catalog number FS-GKR-1N.

Voltage Range

Catalog Number

120V, 50/60 Hz

FSKA-PC120D2

208-277V, 50/60 Hz

FSKA-PC247D2

1.375”
34.9
mm
1.375”
34.9 mm
2.56”
65.0
mm
2.56”
65.0 mm

1.13”
28.7 mm

Photocontrol for Field Installation
Max. Current

Catalog Number

120 V, 50/60 Hz

Voltage Range

8.3 Amp

PC120D2

208-277 V, 50/60 Hz

3.5 Amp

34.9 mm
PC247D2

2.56”
65.0 mm

Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

1.375”

0.69”
17.5 mm
1.19”
30.2 mm

1.94”
49.2 mm

991

Mercmaster™ III 400 Luminaire Photometric Data
400 W PSMH

Listed for si­mul­ta­ne­ous ex­po­sure to com­bust­i­ble dusts and flam­ma­ble gas­es or va­pors.
* Photometric data is based on a fixture with
a 400-watt clear Pulse Start Metal Halide lamp
(44,000 lumen).

Lighting: Enclosed and Gasketed — Area — HID

Lighting

Zone

For candlepower values of fixtures with other
PSMH lamps, use the following multipliers: for a 320
W (33,000 lumen) PSMH lamp – .750; for a 350 W
(37,000 lumen) PSMH lamp – .840. For candlepower
values of fixture with guard, multiply by – 0.95.

Lumens

Total Luminaire Efficiency = 92.6%

0-10

118.85

CIE Type - General Diffuse

10-20

488.36

20-30

948.99

30-40

1678.84

Coefficients of Utilization - Zonal Cavity Method

40-50

2714.15

Effective Floor Cavity Reflectance 0.20

50-60

3299.55

% Ceiling Rcc

60-70

3919.47

% Walls

70-80

4497.45

80-90

4892.41

90-100

REPORT NUMBER: KP40PG
Lamps: 400 W Pulse Start Metal Halide with Globe *

Lumens

70

50

30

10

0

0 100100100100 93 93 93 93 80 80 80 68 68 68 57 57 57 51

Zonal Lumen Summary
Zone

80

Rw 70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0

1 86 80 74 69 79 73 68 64 62 58 54 51 48 45 41 39 37 32

% Lamp % Fixture

4803.79

0-30

1556.19

3.5

3.8

2 76 67 59 52 70 61 54 48 51 45 41 42 37 33 33 30 27 22

100-110 4404.56

0-40

3235.03

7.4

7.9

3 68 57 48 41 62 52 44 38 45 37 32 35 30 26 28 24 20 16

110-120 3849.71

0-60

9248.74

21.0

22.7

4 62 49 40 33 56 45 37 30 37 31 26 30 25 21 24 20 16 13

120-130 3078.18

0-90

22558.07

51.3

55.4

5 56 43 34 27 51 40 31 25 33 26 21 27 21 17 21 17 13 10

130-140 1852.83

90-120 13058.07

29.7

32.0

6 51 38 29 23 47 35 27 21 29 23 18 24 18 14 18 14 11

8

140-150

185.86

90-130 16136.25

36.7

39.6

7 47 34 25 20 43 31 24 18 26 20 15 21 16 12 17 12

9

7

150-160

14.88

90-150 18174.93

41.3

44.6

8 44 31 22 17 40 28 21 16 24 17 13 19 14 10 15 11

8

6

160-170

1.78

90-180 18191.71

41.3

44.6

9 41 28 20 15 37 26 18 14 21 15 11 18 13

9 14 10

7

5

170-180

0.12

0-180

92.6

100.0

10 38 25 18 13 35 23 16 12 20 14 10 16 11

8 13

6

4

Zone

40749.78

9

Lumens

Total Luminaire Efficiency = 81.4%

0-10

561.93

CIE Type - Direct

10-20

1748.92

20-30

2859.54

30-40

4018.21

0-180

1.76

Coefficients of Utilization - Zonal Cavity Method

40-50

5254.58

90-270

1.76

Effective Floor Cavity Reflectance 0.20

50-60

5772.38

Diagonal

1.86

60-70

6052.84

70-80

5887.04

80-90

3512.71

90-100

137.17

0-30

5170.39

11.8

14.4

2 74 65 58 51 72 63 57 51 60 54 49 57 52 48 55 51 47 45

100-110

0.00

0-40

9188.60

20.9

25.7

3 66 55 47 40 64 54 46 40 51 44 39 49 43 38 46 42 37 35

110-120

0.00

0-60

20215.55

45.9

56.5

4 60 48 39 32 58 47 39 32 44 37 32 42 36 31 40 35 31 28

120-130

0.00

0-90

35668.14

81.1

99.6

5 55 42 33 27 53 41 33 27 39 32 26 37 31 26 36 30 26 24

130-140

0.00

90-120

137.17

0.3

0.4

6 50 37 29 23 48 36 28 23 35 28 22 33 27 22 32 26 22 20

140-150

0.00

90-130

137.17

0.3

0.4

7 46 33 25 20 44 33 25 19 31 24 19 30 24 19 29 23 19 17

150-160

0.00

90-150

137.17

0.3

0.4

8 43 30 22 17 41 30 22 17 28 22 17 27 21 17 26 21 17 15

160-170

0.00

90-180

137.17

0.3

0.4

9 40 28 20 15 38 27 20 15 26 19 15 25 19 15 24 19 15 13

170-180

0.00

0-180

35805.32

81.4

100.0

10 37 25 18 13 36 25 18 13 24 18 13 23 17 13 22 17 13 12

992

REPORT NUMBER: KP40PST
Lamps: 400 W Pulse Start Metal Halide with
Standard Dome Reflector *

Spacing
Criteria

Plane

% Ceiling Rcc
% Walls

Lumens

70

50

30

10

0

Rw 70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0
0 97 97 97 97 95 95 95 95 90 90 90 86 86 86 83 83 83 81

Zonal Lumen Summary
Zone

80

% Lamp % Fixture

1 84 78 73 68 81 76 71 67 72 69 65 69 66 63 66 63 61 59

Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

Mercmaster™ III 400 Luminaire Photometric Data
400 W PSMH

Listed for si­mul­ta­ne­ous ex­po­sure to com­bust­i­ble dusts and flam­ma­ble gas­es or va­pors.
* Photometric data is based on a fixture with
a 400-watt clear Pulse Start Metal Halide lamp
(44,000 lumen).

Zone

For candlepower values of fixtures with other
PSMH lamps, use the following multipliers: for a 320
W (33,000 lumen) PSMH lamp – .750; for a 350 W
(37,000 lumen) PSMH lamp – .840. For candlepower
values of fixture with guard, multiply by – 0.95.

Lumens

Total Luminaire Efficiency = 76%

0-10

499.96

CIE Type - Direct

10-20

1605.38

20-30

2680.72

30-40

3841.49

0-180

2.28

Coefficients of Utilization - Zonal Cavity Method

40-50

4899.23

90-270

1.92

Effective Floor Cavity Reflectance 0.20

50-60

4819.21

Diagonal

1.84

60-70

4564.58

70-80

4063.65

80-90

3258.13

90-100

2105.14

100-110

762.24

110-120

138.12

0-30

120-130

77.59

130-140

73.07

140-150
150-160

Spacing
Criteria

Plane

% Ceiling Rcc
% Walls

80

70

50

30

Lighting

REPORT NUMBER: KP40PAN
Lamps: 400 W Pulse Start Metal Halide with
30° Angle Dome Reflector *

10

0

Rw 70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0

1 78 72 68 64 75 70 66 62 65 62 59 61 58 56 57 55 53 50
2 69 61 55 49 66 59 53 48 55 50 46 51 47 43 48 44 41 39

Zonal Lumen Summary
Zone

Lumens

% Lamp % Fixture

3 62 52 45 39 59 51 44 38 47 41 37 44 39 35 41 37 33 31

4786.06

10.9

14.3

4 56 46 38 32 54 44 37 31 41 35 30 38 33 29 36 31 28 26

0-40

8627.55

19.6

25.8

5 51 40 33 27 49 39 32 26 36 30 25 34 29 24 32 27 23 21

0-60

18345.99

41.7

54.9

6 47 36 28 23 45 35 28 22 32 26 22 30 25 21 29 24 20 18

25.07

0-90

30232.35

68.7

90.4

7 43 32 25 20 42 31 24 19 29 23 19 27 22 18 26 21 17 16

10.91

90-120

3005.49

6.8

9.0

8 40 29 22 17 39 28 22 17 27 21 16 25 20 16 24 19 15 14

160-170

5.30

90-130

3083.09

7.0

9.2

9 37 26 20 15 36 26 19 15 24 19 15 23 18 14 22 17 14 12

170-180

1.45

90-150

3181.23

7.2

9.5

10 35 24 18 14 34 24 17 13 22 17 13 21 16 13 20 15 12 11

90-180

3198.89

7.3

9.6

0-180

33431.25

76.0

100.0

Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

993

Lighting: Enclosed and Gasketed — Area — HID

0 89 89 89 89 86 86 86 86 80 80 80 75 75 75 71 71 71 69

Mercmaster™ III 400 Luminaire Photometric Data
400 W PSMH

Listed for si­mul­ta­ne­ous ex­po­sure to com­bust­i­ble dusts and flam­ma­ble gas­es or va­pors.
* Photometric data is based on a fixture with
a 400-watt clear Pulse Start Metal Halide lamp
(44,000 lumen).

Lighting: Enclosed and Gasketed — Area — HID

Lighting

Zone

Lumens

For candlepower values of fixtures with other
PSMH lamps, use the following multipliers: for a 320
W (33,000 lumen) PSMH lamp – .750; for a 350 W
(37,000 lumen) PSMH lamp – .840. For candlepower
values of fixture with guard, multiply by – 0.95.

Total Luminaire Efficiency = 78.4%

REPORT NUMBER: KP40PJ5
Lamps: 400 W Pulse Start Metal Halide with
8” Prismatic Glass Refracter - NEMA Type V *

CIE Type - Semi-Direct

0-10

77.24

10-20

575.14

20-30

1061.45

30-40

1581.40

0-180

1.36

40-50

4468.52

90-270

1.40

50-60

4938.88

Diagonal

2.42

60-70

6338.26

70-80

5875.90

80-90

3886.90

90-100

1318.17

0-30

1713.83

3.9

5.0

1 77 71 66 61 73 68 63 59 62 58 54 57 53 50 52 49 47 44

100-110 1872.98

0-40

3295.23

7.5

9.6

2 67 58 50 44 64 55 48 42 50 44 39 45 41 37 41 37 34 31

110-120 1122.17

0-60

12702.64

28.9

36.8

3 59 48 40 33 56 46 38 32 42 35 30 38 32 27 34 29 25 23

120-130

616.83

0-90

28803.69

65.5

83.5

4 53 41 33 26 50 39 31 25 35 29 23 32 26 21 29 24 20 17

130-140

358.56

90-120

4313.33

9.8

12.5

5 48 36 27 21 45 34 26 20 31 24 18 28 22 17 25 20 16 13

140-150

224.03

90-130

4930.15

11.2

14.3

6 44 31 23 17 41 30 22 16 27 20 15 24 18 14 22 17 13 11

150-160

128.38

90-150

5512.75

12.5

16.0

7 40 28 20 14 38 26 19 14 24 17 13 22 16 12 19 14 11

9

160-170

50.79

90-180

5699.61

13.0

16.5

8 37 25 17 12 35 24 17 11 22 15 11 19 14 10 18 13

9

7

170-180

7.69

0-180

34503.3

78.4

100.0

9 34 22 15 10 32 21 15 10 20 13

Spacing
Criteria

Plane

Coefficients of Utilization - Zonal Cavity Method
Effective Floor Cavity Reflectance 0.20
% Floors Rfc
% Ceiling Rcc

Zonal Lumen Summary
Zone

Lumens

% Walls

20
80

70

30

9 30 20 13

9 18 12

8 16 11

8

6

8 16 11

7 15 10

7

5

Total Luminaire Efficiency = 64.2%

0-10

514.26

CIE Type - Direct

10-20

1734.49

20-30

3370.99

30-40

5333.06

0-180

2.32

Coefficients of Utilization - Zonal Cavity Method

40-50

7165.13

90-270

2.32

Effective Floor Cavity Reflectance 0.20

50-60

6195.93

Diagonal

2.04

60-70

2879.28

70-80

921.95

80-90

111.28

REPORT NUMBER: KP40PHB
Lamps: 400 W Pulse Start Metal Halide with
Enclosed Reflector (KPR-4HB) *

Spacing
Criteria

% Floors Rfc
% Ceiling Rcc

Zonal Lumen Summary
Zone

Lumens

0

9 18 12

Lumens

Plane

10

0 90 90 90 90 87 87 87 87 80 80 80 74 74 74 68 68 68 65

% Lamp % Fixture

10 32 20 14

Zone

50

Rw 70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0

% Walls

% Lamp % Fixture

20
80

70

50

30

10

0

Rw 70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0
0 76 76 76 76 75 75 75 75 71 71 71 68 68 68 65 65 65 64

90-100

0.14

0-30

5619.74

12.8

19.9

1 70 67 65 63 69 66 64 62 63 61 60 61 59 58 59 57 56 55

100-110

0.00

0-40

10952.81

24.9

38.8

2 64 59 55 51 62 58 54 50 55 52 49 53 51 48 51 49 47 46

110-120

0.00

0-60

24313.86

55.3

86.1

3 58 51 46 42 56 50 46 42 48 44 41 47 43 40 45 42 40 38

120-130

0.00

0-90

28226.37

64.2

100.0

4 53 45 39 35 51 44 39 35 43 38 34 41 37 34 40 36 33 32

130-140

0.00

90-120

0.14

0.0

0.0

5 48 40 34 30 47 39 34 29 38 33 29 36 32 29 35 31 28 27

140-150

0.00

90-130

0.14

0.0

0.0

6 44 35 29 25 43 35 29 25 34 29 25 32 28 25 31 28 24 23

150-160

0.00

90-150

0.14

0.0

0.0

7 41 32 26 22 39 31 26 22 30 25 22 29 25 21 28 24 21 20

160-170

0.00

90-180

0.14

0.0

0.0

8 37 29 23 19 36 28 23 19 27 22 19 26 22 19 26 22 19 17

170-180

0.00

0-180

28226.50

64.2

100.0

9 35 26 20 17 34 25 20 17 25 20 17 24 20 16 23 19 16 15
10 32 24 18 15 32 23 18 15 23 18 15 22 18 15 21 17 15 13

994

Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

LN Series Wellglass Luminaires

Zone 2 and 22
Zone 2 and 22
II 3 GD
ATEX / IEC IP66

Applications

Lighting

Low Profile Ceiling Mount with
Prismatic Globe and Optional Guard

50-200 Watt 25° Stanchion Mount
with Prismatic Globe

50-200 Watt 90° Stanchion Mount
with Prismatic Globe and
Optional Guard

400 Watt Straight Stanchion Mount
with Prismatic Glass Globe and
Optional Guard

Features
•	 Power supply 230/240 V (+6% - 10%) 50 Hz.
•	 Instant relighting with auxiliary halogen lamps, depending on
model (lamps not supplied).
•	 Fast relighting for 70 W and 150 W sodium: 5 to 30 seconds
depending on the duration of the mains power supply failure.
•	 Connection via terminal block (0.003 x 0.006 in2 /
2 x 4 mm2 max.).
•	 Superior corrosion-resistance: copperfree die-cast mounting
hoods, ballast housing and guards have a gray epoxy powder
coat, electrostatically applied for complete and uniform
protection.
•	 Wide choice of light sources: high pressure sodium, metal
halide, mercury vapor and incandescent.
•	 Six mounting arrangements to suit any lighting layout – pendant,	
ceiling, wall bracket, angled or straight stanchion and pendant
cone (for dust applications).
•	 Hinge has high lip for added safety during installation
and servicing. Hinge and bolt construction assures 360°
compression at all points on ballast housing gasket for positive
sealing. Swing away design of captive bolt and nut simplifies
servicing.
•	 All fixtures designed to perform in a -40 °F/-40 °C ambient
temperature up to 131 °F/55 °C.
•	 Standard dome or 30° angle reflectors made of fiberglass
reinforced white polyester. Highly resistant to corrosive
atmospheres and vented to improve fixture cooling
characteristics.
•	 Fixture housing mounting hoods and guards are die-cast
copperfree aluminum with epoxy powder coat finish.
•	 All exposed hardware is stainless steel and captive. Stainless
thread inserts in the ballast bodies prevent “freezing” of the
screws that affix guards and reflectors, simplifying removal for
service.
•	 One-piece ballast housing for each component provides even
heat dissipation for cooler operation and longer ballast life.
•	 Fixture bodies are provided with two silicone rubber O-Ring
style gaskets that will stay flexible and assure even compression
around their circumference. They easily withstand high
temperatures, moisture, dirt and dust for worry free operation.

Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

Standard Materials
•	 Mounting hoods and ballast bodies: die-cast copperfree (4/10
of 1% max.) aluminum
•	 Hardware and catch assemblies: stainless steel
•	 Globe: heat and impact resistant internally fluted glass
•	 Gasket: high temperature silicon
•	 Reflector: fiberglass reinforced polyester
•	 Guards: polyester powder coat finished cast copperfree
aluminum (LN1 and LN2 sizes) or stainless steel (LN3 and LN4
sizes)

Standard Finishes
•	 Mounting hoods, ballast bodies and guards: epoxy powder coat
finish, electrostatically applied for complete, uniform surface
protection
•	 Reflectors: white polyester finish

995

Lighting: Enclosed and Gasketed — Area — HID

•	 Enclosed and gasketed fixtures suitable for use in:
— Marine and wet locations
— Areas where flammable gases, vapors or combustible dusts
are present under conditions defined by the IEC as Zone 2
and 22
— Applications where energy efficient, high lumen output is
required
— Non-hazardous locations where severe weather conditions,
excessive moisture, dirt, dust, corrosive atmosphere or high
ambient temperatures are encountered
•	 Typical applications include:
— Pulp and paper mills
— Processing plants
— Chemical plants
— Oil refineries
— Foundries
— Manufacturing plants
— Storage areas
— Waste and sew­age treat­ment
— Oth­er ar­e­as where dust, wa­ter, dirt and rough us­age are a
prob­lem

LN Series Wellglass Luminaires

Zone 2 and 22
Zone 2 and 22
II 3 GD
ATEX / IEC IP66

Lighting: Enclosed and Gasketed — Area — HID

Lighting

Certifications and Compliances
•	
	
	
	
	
	
	
	
	
•	
	
	
	
	
	
	
	
	
•	
•	
•	
•	

Gas: Certification Type LN
— Zone 2
— Conforming to ATEX 94/9/CE: CE
II3 G
— ATEX/IEC Protection: Ex nR II
— Ambient Temperature: 104 °F/40 °C to 131 °F/55 °C
— CE Declaration of Conformity: 50217
— ATEX Certificate: LCIE 08 ATEX 6036X
— IEC Certificate: LCIE Ex 08.003X
— Other Certifications: GOST
Dust: Certification Type LN
— Zone 22
— Conforming to ATEX 94/9/CE: CE
II3 D
— ATEX/IEC Protection: Ex tD A22
— Ambient Temperature: 104 °F/40 °C to 131 °F/55 °C
— CE Declaration of Conformity: 50217
— ATEX Certificate: LCIE 08 ATEX 6036X
— IEC Certificate: LCIE Ex 08.003X
— Other Certifications: GOST
Ex standards :EN / IEC 60079-0; 60079-15; 61241-0; 61241-1
Product standards: EN / IEC 60598-1
EMC standards: EN / IEC 55015; 61547
Other standards: EN / IEC 60529 (IP)

Order using catalog numbering guide below or select catalog number from tables on following pages.
Catalog Numbering Guide for LN Series Luminaires
LN

1

Series:
LN - LN Series	
Zone 2, 22
ATEX/IEC Certified

A
Mounting:
A - Pendant 	
(Rigid
Mounting)
C - Ceiling
D - Pendant Cone
F - Pendant	
(Flexible 	
Mounting)
R - Straight
Stanchion
S - 25° Stanchion
W - Wall

Body Size:
1 -  Size 1 (MLBG)
2 -  Size 2 (KPB)
3 -  Size 3 (KPBR)
4 -  Size 4 (KPB400)

996

H

70

A

Lamp Wattage:
70 - 70 W
80 - 80 W
85 - 85 W
Induction only
10 - 100 W
12 - 125 W
15 - 150 W
25 - 250 W
40 - 400 W

Lamp Type:
H - Metal Halide
L - Sodium
M - Mercury Vapor
Q - Induction
Z - Halogen/	
Incandescent

G2

XA

Globe:
G2 - Glass Globe
VPGL-2HR
G4 - Glass Globe
VPGL-4HR

Hub Size:
A - M20
2 - 3/4" NPT
3 - 1" NPT
4 - 1-1/4" NPT
5 - 1-1/2" NPT

P
Options:
P - PTFE Coating

Voltage (Magnetic Ballast):
XA - 220 Vac 50 Hz
XJ - 230/240 Vac 50 Hz

Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

LN Series Wellglass Luminaires

Zone 2 and 22
Zone 2 and 22
II 3 GD
ATEX / IEC IP66

T Rating for Zone 2 Locations
Not available for Zone 22 locations

Zone 2 T Rating Ambient Temperatures

Lighting

Zone 22 Surface Temperature for
Ambient T° = +131 °F/+55°C
Dust Surface
Cable

+122 °F/+50°C

+131 °F/+55°C

T Rating

T4

T4

T4

235 °F/113 °C

—

100 W HPS

T Rating

T4

T3

T3

289 °F/143 °C

—

100 W Incandescent

T Rating

T4

T3

T3

289 °F/143 °C

—

100 W Halogen

T Rating

T4

T3

T3

289 °F/143 °C

—

125 W Mercury

T Rating

T4

T3

T3

289 °F/143 °C

—

150 W HPS

T Rating

T4

T3

T3

289 °F/143 °C

—

150 W Halide

T Rating

T4

T3

T3

289 °F/143 °C

—

150 W Incandescent

T Rating

T4

T3

T3

289 °F/143 °C

—

150 W Halogen

T Rating

T4

T3

T3

289 °F/143 °C

—

250 W HPS

T Rating

T4

T4

T3

279 °F/137 °C

—

250 W Halide

T Rating

T4

T3

T3

289 °F/143 °C

—

250 W Mercury

T Rating

T4

T3

T3

289 °F/143 °C

—

T Rating

T3

T3

T3

Cable T°

–

183 °F/84 °C

192 °F/89 °C

333 °F/167 °C

192 °F/89 °C

340 °F/171 °C

189 °F/87 °C

340 °F/171 °C

192 °F/89 °C

400 W HPS

400 W Halide

400 W Mercury

T Rating

T3

T3

T3

Cable T°

–

180 °F/82 °C

189 °F/87 °C

T Rating

T3

T3

T3

Cable T°

–

183 °F/84 °C

192 °F/89 °C

“T” Numbers Represent the Maximum Lamp Temperature Locations and Maximum Surface Temperature Under Dust Blanket.
“T”
Number

T1

350

325

T2

T2A

T2B

T2C

T2D

T3

T3A

T3B

T3C

T4

T4A

T5

T6

Temp.
Range
(˚ºF)

664842

619662

574617

538572

502536

448500

421446

394419

358392

331356

322329

277320

250275

214248

187212

185

Temp.
Range
(°C)

351450

326350

301325

281300

261280

231260

216230

201215

181200

166180

161165

136160

121135

101120

86100

85

Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

997

Lighting: Enclosed and Gasketed — Area — HID

+104 °F/+40°C
70 W HPS

LN Series Wellglass Luminaires

Zone 2 and 22
Zone 2 and 22
II 3 GD
ATEX / IEC IP66

Lamp
Type

Cable Entry

Lamp
Watts

Lampholder

Weight
Lbs/kg

Volume
(in3/dm3)

Catalog
Number

70

E27

16.31/7.4

2379.93/39

LN1AL702G2XJ

100

E40

19.84/9.0

3356.31/55

LN2AL102G2XJ

150

E40

19.84/9.0

3356.31/55

LN2AL152G2XJ

250

E40

35.27/16.0

4271.66/70

LN3AL252G4XJ

400

E40

41.89/19.0

5199.22/85.2

LN4AL402G4XJ

Lighting

Pendant

Lighting: Enclosed and Gasketed — Area — HID

HPS

1 x 3/4” NPT

Pendant Cone

HPS

1 x 3/4” NPT

70

E27

16.31/7.4

2379.93/39

LN1DL702G2XJ

100

E40

19.84/9.0

3356.31/55

LN2DL102G2XJ

150

E40

19.84/9.0

3356.31/55

LN2DL152G2XJ

250

E40

35.27/16.0

4271.66/70

LN3DL252G4XJ

400

E40

41.89/19.0

5199.22/85.2

LN4DL402G4XJ

Ceiling

HPS

5 x 1” NPT with:	
- 4 x 1” NPT fitted plugs	
- 2 x 1” NPT-M20 adaptors	
- 2 x M20 plugs

70

E27

16.31/7.4

2379.93/39

LN1CL70AG2XJ

100

E40

19.84/9.0

3356.31/55

LN2CL10AG2XJ

150

E40

19.84/9.0

3356.31/55

LN2CL15AG2XJ

250

E40

35.27/16.0

4271.66/70

LN3CL25AG4XJ

400

E40

41.89/19.0

5199.22/85.2

LN4CL40AG4XJ

Wall

HPS

5 x 1” NPT with:	
- 4 x 1” NPT fitted plugs	
- 2 x 1” NPT-M20 adaptors	
- 2 x M20 plugs

70

E27

16.31/7.4

2379.93/39

LN1WL70AG2XJ

100

E40

19.84/9.0

3356.31/55

LN2WL10AG2XJ

150

E40

19.84/9.0

3356.31/55

LN2WL15AG2XJ

250

E40

35.27/16.0

4271.66/70

LN3WL25AG4XJ

400

E40

41.89/19.0

5199.22/85.2

LN4WL40AG4XJ

25° Angled Stanchion

HPS

1 x1- 1/4” NPT

70

E27

16.31/7.4

2379.93/39

LN1SL704G2XJ

100

E40

19.84/9.0

3356.31/55

LN2SL104G2XJ

150

E40

19.84/9.0

3356.31/55

LN2SL154G2XJ

250

E40

35.27/16.0

4271.66/70

LN3SL254G4XJ

400

E40

41.89/19.0

5199.22/85.2

LN4SL404G4XJ

Straight Stanchion

HPS

998

1 x1- 1/4” NPT

70

E27

16.31/7.4

2379.93/39

LN1RL704G2XJ

100

E40

19.84/9.0

3356.31/55

LN2RL104G2XJ

150

E40

19.84/9.0

3356.31/55

LN2RL154G2XJ

250

E40

35.27/16.0

4271.66/70

LN3RL254G4XJ

400

E40

41.89/19.0

5199.22/85.2

LN4RL404G4XJ

Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

LN Series Wellglass Luminaires

Zone 2 and 22
Zone 2 and 22
II 3 GD
ATEX / IEC IP66

Lamp Type

Cable Entry

Lamp
Watts

Lampholder

Weight
Lbs/kg

Volume
(in3/dm3)

Catalog
Number

100

E27

16.31/7.4

2379.93/39

LN1AZ102G2

150

E27

16.31/7.4

2379.93/39

LN1AZ152G2

100

E27

16.31/7.4

2379.93/39

LN1DZ102G2

150

E27

16.31/7.4

2379.93/39

LN1DZ152G2

Pendant

Inc./	
Halogen

1 x 3/4” NPT

Inc./	
Halogen

5 x 1” NPT with:	
- 4 x 1” NPT fitted plugs	
- 2 x 1” NPT-M20 adaptors	
- 2 x M20 plugs

100

E27

16.31/7.4

2379.93/39

LN1CZ10AG2

150

E27

16.31/7.4

2379.93/39

LN1CZ15AG2

5 x 1” NPT with:	
- 4 x 1” NPT fitted plugs	
- 2 x 1” NPT-M20 adaptors	
- 2 x M20 plugs

100

E27

16.31/7.4

2379.93/39

LN1WZ10AG2

150

E27

16.31/7.4

2379.93/39

LN1WZ15AG2

100

E27

16.31/7.4

2379.93/39

LN1SZ104G2

150

E27

16.31/7.4

2379.93/39

LN1SZ154G2

100

E27

16.31/7.4

2379.93/39

LN1RZ104G2

150

E27

16.31/7.4

2379.93/39

LN1RZ154G2

Pendant Cone

Ceiling

Wall
Inc./	
Halogen

25° Angled Stanchion
Inc./	
Halogen

1 x1- 1/4” NPT

Inc./	
Halogen

1 x1- 1/4” NPT

Straight Stanchion

Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

999

Lighting: Enclosed and Gasketed — Area — HID

1 x 3/4” NPT

Lighting

Inc./	
Halogen

LN Series Wellglass Luminaires

Zone 2 and 22
Zone 2 and 22
II 3 GD
ATEX / IEC IP66

Lamp Type

Lamp
Watts

Lampholder

Weight
Lbs/kg

150

E27

16.31/7.4

250

E40

30.86/14.0

4271.66/70 LN3AM252G4XJ

400

E40

41.89/19.0

5199.22/85.2 LN4AM402G4XJ

150

E27

16.31/7.4

2379.93/39 LN1DM122G2XJ

250

E40

30.86/14.0

4271.66/70 LN3DM252G4XJ

400

E40

41.89/19.0

5199.22/85.2 LN4DM402G4XJ

5 x 1” NPT with:	
- 4 x 1” NPT fitted plugs	
- 2 x 1” NPT-M20 adaptors	
- 2 x M20 plugs

150

E27

16.31/7.4

2379.93/39 LN1CM12AG2XJ

250

E40

30.86/14.0

4271.66/70 LN3CM25AG4XJ

400

E40

41.89/19.0

5199.22/85.2 LN4CM40AG4XJ

5 x 1” NPT with:	
- 4 x 1” NPT fitted plugs	
- 2 x 1” NPT-M20 adaptors	
- 2 x M20 plugs

150

E27

16.31/7.4

2379.93/39 LN1WM12AG2XJ

250

E40

30.86/14.0

4271.66/70 LN3WM25AG4XJ

400

E40

41.89/19.0

5199.22/85.2 LN4WM40AG4XJ

150

E27

16.31/7.4

2379.93/39 LN1SM124G2XJ

250

E40

30.86/14.0

4271.66/70 LN3SM254G4XJ

400

E40

41.89/19.0

5199.22/85.2 LN4SM404G4XJ

150

E27

16.31/7.4

2379.93/39 LN1RM124G2XJ

250

E40

30.86/14.0

4271.66/70 LN3RM254G4XJ

400

E40

41.89/19.0

5199.22/85.2 LN4RM404G4XJ

Cable Entry

Volume
(in3/dm3)

Catalog
Number

Lighting: Enclosed and Gasketed — Area — HID

Lighting

Pendant
MV

1 x 3/4” NPT

2379.93/39 LN1AM122G2XJ

Pendant Cone
MV

1 x 3/4” NPT

Ceiling
MV

Wall
MV

25° Angled Stanchion
MV

1 x 1-1/4” NPT

Straight Stanchion
MV

1000

1 x 1-1/4” NPT

Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

LN Series Wellglass Luminaires

Zone 2 and 22
Zone 2 and 22
II 3 GD
ATEX / IEC IP66

Lamp
Type

Cable Entry

Lamp
Watts

Lampholder

Weight
Lbs/kg

Volume
(in3/dm3)

Catalog
Number

150

E40

19.84/9.0

3356.31/55

LN2AH152G2XJ

4271.66/70

LN3AH252G4XJ

Pendant
1 x 3/4” NPT

250

E40

35.27/16.0

400

E40

41.89/19.0

5199.22/85.2 LN4AH402G4XJ

1 x 3/4” NPT

150

E40

19.84/9.0

3356.31/55

LN2DH152G2XJ

250

E40

35.27/16.0

4271.66/70

LN3DH252G4XJ

400

E40

41.89/19.0

5199.22/85.2 LN4DH402G4XJ

Ceiling
MH

5 x 1” NPT with:	
- 4 x 1” NPT fitted plugs	
- 2 x 1” NPT-M20 adaptors	
- 2 x M20 plugs

150

E40

19.84/9.0

3356.31/55

LN2CH15AG2XJ

250

E40

35.27/16.0

4271.66/70

LN3CH25AG4XJ

400

E40

41.89/19.0

5199.22/85.2 LN4CH40AG4XJ

Wall
MH

5 x 1” NPT with:	
- 4 x 1” NPT fitted plugs	
- 2 x 1” NPT-M20 adaptors	
- 2 x M20 plugs

150

E40

19.84/9.0

3356.31/55

LN2WH15AG2XJ

250

E40

35.27/16.0

4271.66/70

LN3WH25AG4XJ

400

E40

41.89/19.0

150

E40

19.84/9.0

5199.22/85.2 LN4WH40AG4XJ

25° Angled Stanchion
MH

1 x 1-1/4” NPT

250

E40

35.27/16.0

400

E40

41.89/19.0

3356.31/55

LN2SH154G2XJ

4271.66/70

LN3SH254G4XJ

5199.22/85.2 LN4SH404G4XJ

Straight Stanchion
MH

1 x 1-1/4” NPT

Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

150

E40

19.84/9.0

3356.31/55

LN2RH154G2XJ

250

E40

35.27/16.0

4271.66/70

LN3RH254G4XJ

400

E40

41.89/19.0

5199.22/85.2 LN4RH404G4XJ

1001

Lighting: Enclosed and Gasketed — Area — HID

Pendant Cone
MH

Lighting

MH

LN Series Wellglass Luminaires

Zone 2 and 22

Item

Description

Catalog Number

White Polyester Reflectors — Furnished with stainless steel screws
Lighting

For Globe Fixtures – LN1 and LN2 sizes
Standard Dome

KR2-ST

30° Angle

KR2-AN

For Glass Refractor Fixtures † – LN3 and LN4 sizes

Lighting: Enclosed and Gasketed — Area — HID

Standard Dome

30° Angle

Standard Dome

CMR-4ST

30° Angle

CMR-4AN

Aluminum

KRGU2

Guards
For Globe Fixtures – LN1 and LN2 sizes
For Glass Refractor Fixtures

†

– LN3 and LN4 sizes
Stainless Steel

Globe Guard

KPGU400

Globe Guard

† Fixtures with refractors are not UL Listed when used with reflectors.

1002

Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

LN Series Wellglass Luminaires

Zone 2 and 22

Ballast Body with Globe

LN2

LN3

LN4

13.52”/346.0 mm

13.52”/346.0 mm

Fix.
12.68”/322.0 mm

Fix.
12.68”/322.0 mm

Fix.
12.68”/322.0 mm

20.50”/520.7 mm

16.73”/425.0 mm

10.83”/275.0 mm

13.52”/346.0 mm
Fix.
12.68”/322.0 mm

Lighting: Enclosed and Gasketed — Area — HID

11.61”/295.0 mm

13.52”/346.0 mm

Lighting

LN1

Mounting Hoods

Pendant

Pendant Cone

12.06”/306.0 mm

Ceiling

12.06”/306.0 mm

1.17”/
30.0 mm

13.62”/346.0 mm
5.59”/
142.0 mm

12.06”/306.0 mm

1.75”/
45.0 mm

5.00”/
127.0 mm

0.375”/
9.5 mm
Dia. (+DFT)

2.00”/
50.8 mm
Dia. (+DFT)

0.56”/
14.3 mm
Dia. (+DFT)

2.50”/
63.5 mm
Dia. (+DFT)

Wall
17.01”/
432.0 mm
10.94”/
278.0 mm

25° Stanchion
3.38”/
85.8 mm

90° Stanchion
17.23”/438.0 mm

(4) Mounting Holes
0.31”/8.0 mm
4.06”/
103.0 mm

12.05”/
306.0 mm

2.00”/
51.0 mm

15.28”/
388.0 mm

9.79”/249.0 mm

9.25”/
235.0 mm
12.05”/
306.0 mm

12.06”/306.0 mm
7.60”/
193.0 mm

Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

1003

LN Series Wellglass Luminaire Photometric Data

Zone 2 and 22

Polar curves for a 1000 lm flux, according to NF C 71-120
Luminaire symbol according to NF C 71-121

Longitudinal
Transverse

High Pressure Sodium
Lighting

70 W HP Sodium
Efficiency 74.6%

Lighting: Enclosed and Gasketed — Area — HID

Degrees

150 W HP Sodium
Efficiency 87.3%

250 W HP Sodium
Efficiency 89.1%
Degrees

Degrees

Degrees

400 W HP Sodium
Efficiency 82.3%

Metal Halide
150 W Metal Halide
Efficiency 82.4%

250 W Metal Halide
Efficiency 96.2%
Degrees

Degrees

400 W Metal Halide
Efficiency 89.8%
Degrees

Incandescent or Halogen
150 W HP Incandescent Halogen
Efficiency 90.6%
Degrees

Mercury Vapor
250 W Mercury Vapor
Efficiency 76%
Degrees

1004

Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

Mercmaster™ II HID Luminaires

High Pressure Sodium and Pulse Start Metal Halide. Mogul Base
UNILETS® for Use with Threaded Metal Conduit.
Class I, Division 2, Groups A, B, C, D †
Class II, Division 1 and 2, Groups E, F, G ‡
Class III
Fixtures Outside Type (Salt Water)

Applications

•	 Superior corrosion-resistance: copperfree aluminum mounting
hoods, ballasts and guards with epoxy powder coat, inside 	
and out.
•	 Standard pendant mounting hood for rigid or flexible mounting.
Balanced round design automatically hangs plumb when used
with flexible hanger.
•	 Positive sealing. Hinge and bolt construction assures 360°
compression at all points on gasket.
•	 One-piece ballast housing for each component provides even
heat dissipation for cooler operation and longer ballast life.
•	 Heat barrier isolates capacitor from ballast. Standard non-PCB
biodegradable capacitors installed in separate compartment.
•	 Mogul socket is furnished with 392 °F/200 °C welded leads,
pre-wired to the ballast.
•	 Porcelain socket assures trouble-free operation in high ambient
installations.
•	 Guards protect globes from damage. Keyhole slots allow easy
installation and are secured with stainless steel screws.
•	 Prismatic glass globes and glass 	
refractors are standard (plastic refractors also available) and
thread directly into fixture housing. Eliminate glare and provide
uniform light distribution.
•	 Vented reflectors result in cooler, dirt-free operation, increased
lumen output.
•	 Reflectors secured to mounting hood with screws (furnished).
•	 Choice of reflector styles: white porcelain enamel or Fiberglass
reinforced polyester; standard dome or 30° angle.
•	 Optional photocell provides automatic “on-off” control.
•	 All Mercmaster mounting hoods have provision for easy field
installation of fuses in fixtures (see fuse kit listings).

Standard Materials
•	 Mounting hoods, ballast bodies and guards: copperfree (4/10 of
1% max.) aluminum
•	 Reflectors: fiberglass reinforced polyester
•	 Globes: 50 W-100 W, threaded prismatic glass; 150 W, 175 W
and 200W, threaded heat-resistant prismatic glass
•	 Refractors: 50 W to 150 W, heat-resistant prismatic glass and
plastic; 175 W to 200 W, prismatic glass

Standard Finishes
•	 Mounting hoods, ballast bodies, guards: epoxy powder-coat
finish. Two-coat baked finish, electrostatically applied for
complete uniform surface protection
•	 Polyester reflectors: natural finish

Options
•	 Fuses for fixtures. For fuse kits see Electrical Specifications and
Fuse Kits page.
•	 MH fixtures for Quartz Auxiliary lamps. Relay switch installed
in fixture when specified. Add suffix -MTE to fixture catalog
number for 120 V through 277 V, and suffix -480E to fixture
catalog number for 480 V fixture.
•	 Smart Hot Restrike emergency option, available for 50 W-150 W
HPS only. Add suffix -SR. See 50 W, 70 W, 100W, 150 W HPS
page.
•	 Hot Restrike option add suffix -R.
•	 Smart Starter available for HPS and PSMH. Add suffix -S.

Certifications and Compliances
•	 UL Standard: UL 1598, UL 1598A, UL 844
•	 UL Listed: E10444

† For specific Class I suitability of each fixture listed, see Thermal Suitability.
‡ For 175 W and 200 W fixtures, use 12” refractor only for Groups E, F and G. Heat-resistant glass globe supplied with 175 W and 200 W fixtures.
Note: Fixtures equipped with optional photocell or quartz auxilliary lamp do not comply with UL requirements and are not suitable for use in classfied locations.
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

1005

Lighting: Enclosed and Gasketed — Area — HID

Features

Lighting

•	 Enclosed and gasketed HID lighting fixtures for use in tunnels,
walkways, bridges, storage facilities, processing plants, parking
lots, foundries, manufacturing plants, power plants and other
locations where moisture, dirt, dust or corrosive atmospheres
are encountered.
•	 Fixtures suited for Class I, Division 2; Class II, Division 1 and
2; and Class III. Suitable for use in wet and outdoor saltwater
locations.
•	 Wide range of wattages and voltages. Choice of ballasts for 100
W-200 W PSMH; and 50 W-150 W HPS lamps in 120, 208, 240,
277 and 480 voltages.
•	 Choice of light sources: high pressure sodium and pulse start
metal halide.
•	 Choice of optical assembles: (1) prismatic globe with or without
guard through 200 W; or (2) Type V closed prismatic glass
refractor through 200 W. (Types II, III and IV also available
through 200 W. Also polycarbonate globes for 100 W max.)
•	 Choice of mounting hoods: pendant (rigid or flexible), 25° (angle)
stanchion, ceiling and wall mounting.
•	 Porcelain reflector for standard applications and Fiberglass
reinforced polyester reflector for installations where luminaire is
subject to exceptionally severe corrosive atmospheres.

Mercmaster™ II HID Luminaires

High Pressure Sodium and Pulse Start Metal Halide. Mogul Base
UNILETS® for Use with Threaded Metal Conduit.
Class I, Division 2, Groups A, B, C, D †
Class II, Division 1 and 2, Groups E, F, G ‡
Class III
Fixtures Outside Type (Salt Water)

Lighting: Enclosed and Gasketed — Area — HID

Lighting

Illustrated Features

High Temperature Sockets
Mogul base high temperature socket for
50W through 400W HID lamps.
Aluminum Inner Reflector
Solid aluminum inner reflector improves
photometric efficiency.

Stainless Steel
Latch Assembly
Captive, stainless
steel latch assembly
bolt and nut closes
securely, resists
attack of corrosive
atmospheres.
Swing-away design
simplifies servicing.

"Safety" High
Hinge
Extra-high hinge
provides additional
protection against
accidental
ballast housing
disengagement
during installation
or maintenance.

Hood/Ballast Gasket
Silicone rubber gasket seals out moisture,
dirt and dust.
Epoxy Finish
Ballast housing, hoods and guards are
copperfree aluminum with epoxy powder
coat finish.
Electrical Protection
Ground wire provided to bond mounting
hood to ballast housing. Fiber insulator
protects ballast and capacitor.

Photocell
Installs through knock-out in mounting
hood; provides continuous ON-OFF duskto-dawn control. Fixtures with optional
photocell or quartz auxiliary lamp do not
comply with UL requirements for use in
classified locations.

JB Series Box and
Flexible Hanger

Balanced Round
Design
Pendant fixtures
automatically hang
plumb. Fixtures and
hangers suitable for
Class I, Division 2
applications.

Fuses Mount to Hood Bosses
Two screws secure fuse kit to mounting
boss in any Mercmaster mounting hood.

† For specific Class I suitability of each fixture listed, see Thermal Suitability.
‡ For 175 W and 200 W fixtures, use 12” refractor only for Groups E, F and G. Heat-resistant glass globe supplied with 175 W and 200 W fixtures.

1006

Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

Mercmaster™ II HID Luminaires

High Pressure Sodium and Pulse Start Metal Halide. Mogul Base
UNILETS® for Use with Threaded Metal Conduit.
Class I, Division 2, Groups A, B, C, D †
Class II, Division 1 and 2, Groups E, F, G ‡
Class III
Fixtures Outside Type (Salt Water)

The quartz emergency lamp socket is wired to a 120 V tap on the ballast and is therefore
independent of the lighting fixture voltage. No special field wiring is necessary.
Description
Catalog Suffix
For fixture volts of 120, 208, 240 or 277
-MTE
For fixture volts of 480
-480E

The hot lamp restart option provides instant restart of 50, 70, 100 and 150 W HPS lamps after
power outages of up to 10 seconds. The lamps restrike instantly at almost full lumens. For power
interruptions of up to 30 seconds, the restart of the high pressure sodium lamp is also instant but
at less than full lumens. The hot lamp restart accessory does not accelerate cold lamp start up or
starting where the power outage is of a duration which has allowed the HPS lamp to cool.

Encapsulated HPS
Smart Hot Restrike
Ignition Accessory

Additional Advantages of the Smart Hot Restrike:
•	 Protects against self destruction in the event of failed, missing or broken lamps,  or socket or
lead wire failure.
•	 Prevents “End of Life” lamps from continuous cycling over long periods of time.
•	 Remains unaffected by stray voltages, moderate overvoltages, as well as undervoltage
conditions.
•	 Drops into the background during normal lamp operation with exceptionally low insertion loss.
•	 Fully encapsulated construction assures electrical integrity and mechanical vibration protection.
•	 UL recognized component.
Description
For fixture watts of 50, 70, 100 or 150 (HPS only)

Accessory Options

Catalog Suffix
-SR

 Guards: Guards are die-cast copperfree aluminum with baked epoxy finish to match fixtures. Fixture
supplied with stainless steel mounting screws which thread into stainless steel inserts on fixture housing to
attach guard. To order fixture with guard, add suffix -G to catalog number before adding voltage suffix.
 Reflectors: Standard dome and 30° angle polyester reflectors.
 Hot Restrike: Instantly restrikes a hot HPS lamp when power is restored after a momentary
outage. Available factory-installed only. To order, add suffix -R to catalog number.
 Quartz Emergency Light: When ordered, HPS fixtures will be supplied with a prewired special
DC bayonet base socket to accept a 150W, 120V quartz lamp (not furnished) that automatically
switches on when a power outage occurs. Fixtures ordered with this quartz emergency lamp feature
do NOT comply with requirements for classified areas and should be used only in non-classified
locations. To order, add suffix -E to catalog number and specify if a relay switch is desired.
 Photocell and Fuses: Photocontrol.
 Smart Starter: Performs as a conventional starter in lamp start-up. Removes itself from circuit at
end of lamp life or if lamp is out of socket. Add suffix -S to catalog number.
 Smart Hot Restrike (HPS only): Will immediately restrike HPS lamp when power is restored after
a momentary power interruption. The smart function removes the hot restrike ignitor from the circuit
if the lamp burns out or is removed from the socket. Eliminates starter failures caused by prolonged
operation with cycling or failing lamps. Add suffix -SR to catalog number.

† For specific Class I suitability of each fixture listed, see Thermal Suitability.
‡ For 175 W and 200 W fixtures, use 12” refractor only for Groups E, F and G. Heat-resistant glass globe supplied with 175 W and 200 W fixtures.
* NOTE: Fixtures equipped with quartz emergency light do not comply with UL requirements and are not suitable for use in classified locations.
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

1007

Lighting: Enclosed and Gasketed — Area — HID

HPS Smart Hot Restrike Accessory for HPS Fixtures
Mercmaster fixtures for high pressure sodium lamps can be supplied with a special ignitor (starter
board). It instantly restrikes a hot high pressure sodium lamp when a momentary power interruption
occurs. This special ignitor, supplied in place of the standard ignitor, is a potted solid state device,
totally factory installed. It is not suitable for field installation.

Lighting

Quartz Emergency Light for Pulse Start Metal Halide or High Pressure Sodium Fixtures *
Mercmaster fixtures for or metal halide and high pressure sodium lamps can be supplied with
a socket to accept a 150 W 120 V quartz lamp. This D.C. bayonet base socket is in addition to
the standard lamp socket. In the event of a momentary power interruption, the quartz lamp is
automatically switched on. The single ended quartz lamp remains energized until the HID restrikes
and reaches about 60% output.

Mercmaster™ II HID Luminaire Thermal Suitability

Class I, Division 2, Groups A, B, C, D; Class II, Division 1, Groups E, F, G
UNILETS® for Use with Threaded Metal Conduit.

Lighting

Class I, Division 2, Groups A, B, C, D †
Class II, Division 1 and 2, Groups E, F, G ‡
Class III
Fixtures Outside Type (Salt Water)

The following table shows maximum operating temperatures	
of Mercmaster fixtures for Class I, Division 2, in a 104 °F/
40 °C ambient in free air as rated by UL. As shown, the higher the
Temperature Identification Number, the cooler the fixture operates.
Keep this in mind when selecting a fixture for a specific chemical
listed on the Classified Area Suitability pages. Per the NEC. The
temperature marking shown on fixtures shall not exceed the

ignition temperature of the gas to be encountered. To illustrate, a
400W HPS fixture, which has a UL-NEC Temperature Identification
Number of 350 (619-662 °F/326-350/°C) does NOT exceed the
Group D Methane (natural gas) ignition temperature of 1004 °F/
540 °C, and is therefore suitable for use in atmospheres containing
that chemical.

Mercmaster II Thermal Suitability

Watts

Type

Supply
Wire
Temp.
(°F/°C)

  50

HPS

194/90

104/40

T3

T3

T3A

T3A

T3B

T3B

T3B

T3B

  70

HPS

194/90

104/40

T3

T3

T3A

T3A

T3B

T3B

T3B

T3B

100

HPS

194/90

104/40

T2C

T2C

T3

T3

T3B

T3B

T3B

T3B

150

HPS

194/90

104/40

T2A

T2A

T2B

T2B

➊

➊

➊

T3B

150

PSMH

194/90

104/40

T2B

T2B

T2D

T2D

—

—

—

—

175

PSMH

194/90

104/40

T2B

T2B

T2C

T2C

—

—

—

—

200

PSMH

194/90

104/40

T2

T2

T2B

T2B

—

—

—

—

Lighting: Enclosed and Gasketed — Area — HID

Lamp

Class I, Division 2, Groups A, B, C, D

Class II, Division 1, Groups E, F G

Ambient
Temp.
(°F/°C)

Globe

Globe &
Reflector

8”
Refractor

12”
Refractor

Globe

Globe &
Reflector

8”
Refractor

12”
Refractor

“T” Numbers Represent the Maximum Lamp Temperature for Class I, Division 2 Locations and
Maximum Surface Temperature Under Dust Blanket for Class II, Division 1 Locations.
“T”
Number

T1

350

325

T2

T2A

T2B

T2C

T2D

T3

T3A

T3B

T3C

T4

T4A

T5

T6

Temp.
Range
(˚ºF)

664842

619662

574617

538572

502536

448500

421446

394419

358392

331356

322329

277320

250275

214248

187212

185

Temp
Range
(°C)

351450

326350

301325

281300

261280

231260

216230

201215

181200

166180

161165

136160

121135

101120

86100

85

All HPS fixtures suitable for operation at -40 °F/-40 °C; PSMH at -20 °F/-29 °C.
† For specific Class I suitability of each fixture listed, see Thermal Suitability above.
‡ For 175 W and 200 W fixtures, use 12” refractor only for Groups E, F and G. Heat-resistant glass globe supplied with 175 W and 200 W fixtures.
➊ Pendant, ceiling and wall mount are suitable for groups E and F only with T3A rating. Stanchion mount is suitable for groups E, F and G with a T3B rating.

1008

Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

Mercmaster™ II HID Luminaires
50 W, 70 W, 100 W, 150 W HPS

High Power Factor (Min. P.F. 90%). Suitable for Use in Wet Locations. Prismatic Glass Globe or Type V Closed Glass Refractor. Mogul Base Lamps.
Class I, Division 2, Groups A, B, C, D †
Class II, Division 1 and 2, Groups E, F, G ‡
Class III
Fixtures Outside Type (Salt Water)

With Globe,
With 8” Refractor
Lamp
Less Guard
(NEMA V)
Watts
Pendant — One Hub, Rigid or Flexible Mounting

70
100

3/4

LPAL5075 ➌

LPAL5075J ➌

LPAL5075R ➌

1

LPAL5010 ➌

LPAL5010J ➌

LPAL5010R ➌

3/4

LPAL7075 ➍

LPAL7075J ➍

LPAL7075R ➍

1

LPAL7010 ➍

LPAL7010J ➍

LPAL7010R ➍

3/4

LPAL1075 ➍

LPAL1075J ➍

LPAL1075R ➍

1

LPAL1010 ➍

LPAL1010J ➍

LPAL1010R ➍

3/4

LPAL1575 ➍

LPAL1575J ➍

LPAL1575R ➍

1

LPAL1510 ➍

LPAL1510J ➍

LPAL1510R ➍

3/4

LPCL5075 ➌

LPCL5075J ➌

LPCL5075R ➌

1

LPCL5010 ➌

LPCL5010J ➌

LPCL5010R ➌

3/4

LPCL7075 ➍

LPCL7075J ➍

LPCL7075R ➍

1

LPCL7010 ➍

LPCL7010J ➍

LPCL7010R ➍

3/4

LPCL1075 ➍

LPCL1075J ➍

LPCL1075R ➍

With 12” Refractor

Ceiling — Five Hubs, Four Close-Up Plugs
50
70
100
150

1

LPCL1010 ➍

LPCL1010J ➍

LPCL1010R ➍

3/4

LPCL1575 ➍

LPCL1575J ➍

LPCL1575R ➍

1

LPCL1510 ➍

LPCL1510J ➍

LPCL1510R ➍

3/4

LPWBL5075 ➌

LPWBL5075J ➌

LPWBL5075R ➌

1

LPWBL5010 ➌

LPWBL5010J ➌

LPWBL5010R ➌

3/4

LPWBL7075 ➍

LPWBL7075J ➍

LPWBL7075R ➍

1

LPWBL7010 ➍

LPWBL7010J ➍

LPWBL7010R ➍

3/4

LPWBL1075 ➍

LPWBL1075J ➍

LPWBL1075R ➍

1

LPWBL1010 ➍

LPWBL1010J ➍

LPWBL1010R ➍

3/4

LPWBL1575 ➍

LPWBL1575J ➍

LPWBL1575R ➍

1

LPWBL1510 ➍

LPWBL1510J ➍

LPWBL1510R ➍

1-1/4

LPSL50125 ➌

LPSL50125J ➌

LPSL50125R ➌

1-1/2

LPSL50150 ➌

LPSL50150J ➌

LPSL50150R ➌

1-1/4

LPSL70125 ➍

LPSL70125J ➍

LPSL70125R ➍

1-1/2

LPSL70150 ➍

LPSL70150J ➍

LPSL70150R ➍

1-1/4

LPSL10125 ➍

LPSL10125J ➍

LPSL10125R ➍

1-1/2

LPSL10150 ➍

LPSL10150J ➍

LPSL10150R ➍

1-1/4

LPSL15125 ➍

LPSL15125J ➍

LPSL15125R ➍

1-1/2

LPSL15150 ➍

LPSL15150J ➍

LPSL15150R ➍

Wall — Five Hubs, Four Close-Up Plugs
50
70
100
150
25° Stanchion — One Hub
50
70
100
150

† For specific Class I suitability of each fixture listed, see Thermal Suitability.
‡ For 175 W and 200 W fixtures, use 12” refractor only for Groups E, F and G. Heat-resistant glass globe supplied with 175 W and 200 W fixtures.
➊ To order fixture with guard, add suffix -G (before adding voltage suffix).
➋ Furnished with 8” NEMA V refractor — to order with NEMA I or III refractor, change J in the catalog number to J1 or J3.
Add voltage suffix -MTMED for Medium Base, 100W (order as special).
➌ Add voltage suffix -MT for 120, 208, 240 or 277 V.
➍ Add voltage suffix -MT for 120, 208, 240 or 277 V; -480 for 480 V.
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

1009

Lighting: Enclosed and Gasketed — Area — HID

150

With Globe ➊

Lighting

50

Catalog Numbers
With 8” Refractor ➋

Hub Size
(Inches)

Mercmaster™ II HID Luminaires
100 W, 150 W, 175 W, 200 W PSMH

Constant Wattage (Min. P.F. 90%). Suitable for Use in Wet Locations. Prismatic Glass Globe or Type V Closed Glass Refractor. Mogul Base Lamps.
Class I, Division 2, Groups A, B, C, D †
Class II, Division 1 and 2, Groups E, F, G ‡
Class III
Fixtures Outside Type (Salt Water)

Lighting

With Globe,
With 8” Refractor
Lamp
Less Guard
(NEMA V)
Watts
Pendant — One Hub, Rigid or Flexible Mounting
100
150

Lighting: Enclosed and Gasketed — Area — HID

175 ‡
200 ‡

Hub Size
(Inches)

With Globe ➊

Catalog Numbers
With 8” Refractor ➋

With 12” Refractor

3/4

LPAH1075 ➍

LPAH1075J ➍

LPAH1075R ➍

1

LPAH1010 ➍

LPAH1010J ➍

LPAH1010R ➍

3/4

LPAP1575 ➍

LPAP1575J ➍

LPAP1575R ➍

1

LPAP1510 ➍

LPAP1510J ➍

LPAP1510R ➍

3/4

LPAP1775 ➍

LPAP1775J ➍

LPAP1775R ➍

1

LPAP1710 ➍

LPAP1710J ➍

LPAP1710R ➍

3/4

LPAP2075 ➍

LPAP2075J ➍

LPAP2075R ➍

1

LPAP2010 ➍

LPAP2010J ➍

LPAP2010R ➍

3/4

LPCH1075 ➍

LPCH1075J ➍

LPCH1075R ➍

1

LPCH1010 ➍

LPCH1010J ➍

LPCH1010R ➍

3/4

LPCP1575 ➍

LPCP1575J ➍

LPCP1575R ➍

1

LPCP1510 ➍

LPCP1510J ➍

LPCP1510R ➍

3/4

LPCP1775 ➍

LPCP1775J ➍

LPCP1775R ➍

1

LPCP1710 ➍

LPCP1710J ➍

LPCP1710R ➍

3/4

LPCP2075 ➍

LPCP2075J ➍

LPCP2075R ➍

1

LPCP2010 ➍

LPCP2010J ➍

LPCP2010R ➍

3/4

LPWBH1075 ➍

LPWBH1075J ➍

LPWBH1075R ➍

1

LPWBH1010 ➍

LPWBH1010J ➍

LPWBH1010R ➍

3/4

LPWBP1575 ➍

LPWBP1575J ➍

LPWBP1575R ➍

1

LPWBP1510 ➍

LPWBP1510J ➍

LPWBP1510R ➍

3/4

LPWBP1775 ➍

LPWBP1775J ➍

LPWBP1775R ➍

Ceiling — Five Hubs, Four Close-Up Plugs
100
150
175 ‡
200 ‡
Wall — Five Hubs, Four Close-Up Plugs
100
150
175 ‡
200 ‡

1

LPWBP1710 ➍

LPWBP1710J ➍

LPWBP1710R ➍

3/4

LPWBP2075 ➍

LPWBP2075J ➍

LPWBP2075R ➍

1

LPWBP2010 ➍

LPWBP2010J ➍

LPWBP2010R ➍

1-1/4

LPSH1075 ➍

LPSH1075J ➍

LPSH1075R ➍

1-1/2

LPSH1010 ➍

LPSH1010J ➍

LPSH1010R ➍

1-1/4

LPSP15125 ➍

LPSP15125J ➍

LPSP15125R ➍

1-1/2

LPSP15150 ➍

LPSP15150J ➍

LPSP15150R ➍

1-1/4

LPSP17125 ➍

LPSP17125J ➍

LPSP17125R ➍

1-1/2

LPSP17150 ➍

LPSP17150J ➍

LPSP17150R ➍

1-1/4

LPSP20125 ➍

LPSP20125J ➍

LPSP20125R ➍

1-1/2

LPSP20150 ➍

LPSP20150J ➍

LPSP20150R ➍

25° Stanchion — One Hub
100
150
175 ‡
200 ‡

† For specific Class I suitability of each fixture listed, see Thermal Suitability.
‡ For 175 W and 200 W fixtures, use 12” refractor only for Groups E, F and G. Heat-resistant glass globe supplied with 175 W and 200 W fixtures.
➊ To order fixture with guard, add suffix -G (before adding voltage suffix).
➋ Furnished with 8” NEMA V refractor — to order with NEMA I or III refractor, change J in the catalog number to J1 or J3.
Add voltage suffix -MTMED for Medium Base, 100W (order as special).
➌ Add voltage suffix -MT for 120, 208, 240 or 277 V.
➍ Add voltage suffix -MT for 120, 208, 240 or 277 V; -480 for 480 V.

1010

Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

Mercmaster™ II HID Luminaires Mounting Hoods and Ballast Bodies
High Pressure Sodium and Pulse Start Metal Halide. Mogul Base
Hoods and Ballast Housings are Copperfree Aluminum (4/10 of 1%).
Class I, Division 2, Groups A, B, C, D †
Class II, Division 1 and 2, Groups E, F, G ‡
Class III
Fixtures Outside Type (Salt Water)

Mounting Hoods
Description

Hub Size (Inches)

Catalog Number

Pendant
Lighting

3/4

LPA-75

1

LPA-100

3/4

LPC-75

1

LPC-100

3/4

LPWB-75

1

LPWB-100

One Hub, Rigid or Flexible Mounting
Ceiling

Wall

Five Hubs, Four Close-Up Plugs

25° Stanchion
1-1/4

LPS-125

1-1/2

LPS-150

One Hub
Mounting Adapter
Permits use of Mercmaster II pendant hood on existing
V-51 and Mercmaster I mounting hoods. Remove
Mercmaster I ballast body from existing mounting hood,
thread in adapter and attach wire to Mercmaster II.

LPAD-1

Mercmaster II Ballast Bodies

Type

Ballast Body Catalog Numbers
Globe/12”
8”
Refractor
Refractor

120V

208V

240V

277V

480V

50

LPB50L

LPBLH50R

-MT

-MT

-MT

-MT

—

Lamp
Watts

Add Voltage Suffixes ➊

High Pressure Sodium
High Power
Factor
(Min. P.F. 90%)

70

LPB70L

LPBLH70R

-MT

-MT

-MT

-MT

-480

100

LPB100L

LPBLH100R

-MT

-MT

-MT

-MT

-480

150

LPB150L

LPBLH150R

-MT

-MT

-MT

-MT

-480

100

LPB100H

LPBH100R

150

LPB150P

LPBP150R

-MT

-MT

-MT

-MT

-480

175

LPB175P

LPBP175R

-MT

-MT

-MT

-MT

-480

200

LPB200P

LPBP200R

-MT

-MT

-MT

-MT

-480

Pulse Start Metal Halide

Constant Wattage
(Min. P.F. 90%)

-MTMED -MTMED -MTMED -MTMED -480MED

† For specific Class I suitability of each fixture listed, see Thermal Suitability.
‡ For 175 W and 200 W fixtures, use 12” refractor only for Groups E, F and G. Heat-resistant glass globe supplied with 175 W and 200 W fixtures.
➊ MT (multi-volt) ballasts can be operated at an input voltage of either 120, 208, 240 or 277 V. 480 ballasts can be operated at input voltage of 480 V.
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

1011

Lighting: Enclosed and Gasketed — Area — HID

Five Hubs, Four Close-Up Plugs

Mercmaster™ II HID Luminaire Accessories

High Pressure Sodium and Pulse Start Metal Halide. Mogul Base

Screws furnished to Fasten Reflectors to Ballast Body. Refractors Thread Directly into Ballast Body.

Description

Catalog Number

Lighting: Enclosed and Gasketed — Area — HID

Lighting

Prismatic Glass Globes
Clear Heat-Resistant

VPGL-2HR

Amber

VPGL-2AM

Blue

VPGL-2BL

Green

VPGL-2GR

Red

VPGL-2RE

Coated Prismatic Tuff-Skin®  Glass Globes
For use in areas where fixture is
subject to extreme thermal shock

Clear Heat-Resistant

VPGL-2HRT

Polycarbonate Globes – Impact-Resistant ➊

Use 100W Lamp max.; do not use in
ambients exceeding 77 °F/25 °C

Light
Distribution

IES/NECA
Distribution Curves

Clear

VPGL-2PL

Amber

VPGL-2AMPL

Green

VPGL-2GRPL

Red

VPGL-2REPL

8” Glass
(50-200 W ➊)

12” Glass
(50-200 W ➊)

12” Polycarbonate
(50-175 W ➋)

NEMA I

LPG-R1

—

—

NEMA II

—

LPRF-2CG

LPRF-2CP

NEMA III

LPG-R3

—

LPRF-3CP

NEMA IV

—

—

LPRF-4CP

NEMA V

LPG-R5

LPRF-5CG

LPRF-5CP

Closed Prismatic Refractors — 50 W-200 W ➊

8” Refractor

12” Refractor

➊ Polycarbonate globes are shatter-resistant – for use in processing plants, canneries, dairies, bakeries or anywhere broken glass would prove a hazard. Ideally
suited for areas where vandalism, high replacement and high maintenance costs are a problem. Do not use in ambients exceeding 77 °F/25 °C. For burning in
vertical base-up positions only.
 Registered trademark of Thomas Manufacturing Corporation, Parkton, Md. It is recommended that guards be used with these globes.
➊ 150 W max. for HPS.
➋ 100 W max. for MH.

1012

Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

Mercmaster™ II HID Luminaire Accessories and Weights
High Pressure Sodium and Pulse Start Metal Halide. Mogul Base

Screws furnished to Fasten Reflectors to Ballast Body. Refractors Thread Directly into Ballast Body.

Description

Catalog Number

Guard
KGU2

Guard for Glass Globe

Lighting

Steel Guards for 8” and 12” Refractors
LPRG2

Guard for 12” Refractor

LPBG12

3 machine screws furnished
LPRG-2

LPBG-12

Polyester Reflectors

Standard Dome

Standard Dome

KR2-ST

30° Angle

KR2-AN

30° Angle

Replacement Gaskets — Silicone Rubber
Globe and 12” Refractor Gasket

VPGL-GK

8” Refractor Gasket

KRF-GK

Photocell (Hazardous)
120 Volt

PC120D2

208 thru 277 Volt

PC247D2

Mounting Hood Weights
Type

Weight (Lbs/Kg)

Type

Weight (Lbs/Kg)

Pendant

3/1.4

Wall

5/2.3

Ceiling

5/2.3

Stanchion

4/1.8

Reflectors and Refractors — Weight includes globe and guard

Watts

HPS

50, 70

14

—

100

15

15

150

16

175

—

200

PSMH

Catalog
Wt. Lbs/Kg
Number
Standard Dome Reflector

Catalog
Wt. Lbs/Kg
Number
30° Angle Reflector

LPG-R1

13/5.9

—

5.25/2.4

LPG-R3

13/5.9

16

5.25/2.4

LPG-R5

13/5.9

2.5/1.1

KR2-AN

Catalog
Wt. Lbs/Kg
Number
12” Refractor

5.25/2.4

2.5/1.1

KR2-ST

Catalog
Wt. Lbs/Kg
Number
8” Refractor

LPRF-5CG

18

Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

1013

Lighting: Enclosed and Gasketed — Area — HID

Guard for 8” Refractor

Mercmaster™ II HID Luminaire Electrical Specifications and Fuse Kits
High Pressure Sodium and Pulse Start Metal Halide. Mogul Base
UNILETS® for Use with Threaded Metal Conduit.
Class I, Division 2, Groups A, B, C, D †
Class II, Division 1 and 2, Groups E, F, G ‡
Class III
Fixtures Outside Type (Salt Water)

Fuse Kit

Lighting: Enclosed and Gasketed — Area — HID

Lighting

Electrical Specifications
Line
Type of
Starting
Voltage
Ballast
Amps
50 Watt High Pressure Sodium
120
HX-HPF
0.58
208
HX-HPF
0.35
240
HX-HPF
0.31
277
HX-HPF
0.25
70 Watt High Pressure Sodium
120
HX-HPF
0.90
208
HX-HPF
0.50
240
HX-HPF
0.44
277
HX-HPF
0.35
480
HX-HPF
0.21
100 Watt High Pressure Sodium
120
HX-HPF
1.30
208
HX-HPF
0.76
240
HX-HPF
0.66
277
HX-HPF
0.60
480
HX-HPF
0.33
150 Watt High Pressure Sodium
120
HX-HPF
2.00
208
HX-HPF
1.15
240
HX-HPF
1.00
277
HX-HPF
0.85
480
HX-HPF
0.50
100 Watt Pulse Start Metal Halide
120
HX-HPF
1.20
208
HX-HPF
0.70
240
HX-HPF
0.61
277
HX-HPF
0.55
480
HX-HPF
0.30
150 Watt Pulse Start Metal Halide
120
HX-HPF
1.75
208
HX-HPF
1.30
240
HX-HPF
0.85
277
HX-HPF
0.77
480
C.W.A.
0.45
175 Watt Pulse Start Metal Halide
120
C.W.A.
0.90
208
C.W.A.
0.50
240
C.W.A.
0.35
277
C.W.A.
0.30
480
C.W.A.
0.25
200 Watt Pulse Start Metal Halide
120
C.W.A.
2.10
208
C.W.A.
1.15
240
C.W.A.
1.10
277
C.W.A.
.75
480
C.W.A.
.58

Operating
Amps

Total
Watts

0.58
0.33
0.29
0.25

64
64
64
64

0.82
0.48
0.41
0.36
0.21

94
94
94
94
94

1.15
0.67
0.60
0.52
0.31

130
130
130
130
135

1.70
0.95
0.85
0.72
0.47

188
188
188
188
189

1.15
0.70
0.58
0.50
0.35

130
130
130
130
140

1.60
1.00
0.80
0.70
0.42

188
188
188
188
185

1.78
1.08
0.89
0.76
0.50

199
199
199
199
213

2.00
1.25
1.00
.85
.50

238
238
238
238
237

Order fuses as a separate item by catalog number from right columns.

Lamp
Watts
50

70

100

150

175

200

Volts
120
208
240
277
120
208
240
277
480
120
208
240
277
480
120
208
240
277
480
120
208
240
277
480
120
208
240
277
480

Fuse Quantity
Required
1
2
2
1
1
2
2
1
2
1
2
2
1
2
1
2
2
1
2
1
2
2
1
2
1
2
2
1
2

Fuse Kit Catalog Number
HPS
PSMH
F5
—
F3
—
F3
—
F2
—
F5
—
F3
—
F3
—
F2
—
F2
—
F8
F6
F5
F4
F5
F3
F3
F3
F3
F2
F10
F10
F5
F5
F5
F5
F5
F4
F3
F3
—
F5
—
F3
—
F3
—
F2
—
F2
—
F9
—
F6
—
F5
—
F4
—
F2

Fuses are filled with non-combustible granular material.
Fuse Kit includes fuse, fuse block, wire, mounting screws
and connectors. All mounting hoods have provisions
for easy field installation of fuses in fixtures.

† For specific Class I suitability of each fixture listed, see Thermal Suitability.
‡ For 175 W and 200 W fixtures, use 12” refractor only for Groups E, F and G. Heat-resistant glass globe supplied with 175 W and 200 W fixtures.

1014

Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

Mercmaster™ II HID Luminaire Dimensions

High Pressure Sodium and Pulse Start Metal Halide. Mogul Base
UNILETS® for Use with Threaded Metal Conduit.

Lighting

25° Angle Stanchion Mount

Ceiling Mount

Wall Mount

Fixture with 8” Refractor

Fixture with Guard and Polyester Reflector

Fixture with 12” Refractor

Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

Lighting: Enclosed and Gasketed — Area — HID

Pendant Mount

1015

Mercmaster™ II HID Luminaire Photometric Data
150 W HPS

UNILETS® for Use with Threaded Metal Conduit.
* Photometric data is based on fixtures with
150-watt clear High Pressure Sodium lamp
(16,000 lumen).

Total Luminaire Efficiency = 86.1%
CIE Type - Semi-Direct

Lighting

Plane

Spacing
Criteria

0-180

2.82

90-270

2.82

Diagonal

2.82

For candlepower values of fixtures with other
HPS lamps, use the following multipliers; for
100 W (9,500 lumen) HPS lamp – 0.594; for 70 W
(6,400 lumen) HPS lamp – 0.40; for 50 W (4,000
lumen) HPS lamp – 0.25. For candlepower
values of fixture with guard, multiply by 0.95.

REPORT NUMBER: LP15LGG
150 W High Pressure Sodium fixture with Globe only *
Coefficients of Utilization - Zonal Cavity Method
Effective Floor Cavity Reflectance 0.20
% Ceiling Rcc

Lighting: Enclosed and Gasketed — Area — HID

% Walls Rw
Zone
0-10
10-20
20-30
30-40
40-50
50-60
60-70
70-80
80-90
90-100
100-110

0
1
2
3
4
5
6
7
8
9
10

Lumens
50.74
164.55
310.47
611.05
961.13
1308.18
1542.35
1716.10
1799.18
1802.19
1676.86

80

70

441.46
9.61
3.33
0.74
0.00
0.00

Total Luminaire Efficiency = 73.6%
CIE Type - Direct
Plane

Spacing
Criteria

0-180

1.46

90-270

1.46

Diagonal

1.68
Lumens
266.98
799.41
1337.05
1732.06
2067.60
2317.60
2210.81
866.77
145.09
14.46
8.75
7.93

120-130
130-140
140-150
150-160
160-170
170-180

4.51
2.16
0.48
0.00
0.00
0.00

1016

10

0

30

10

70

50

30

10

50

30

10

50

30

10

50

30

10

0

95
81
71
64
57
52
48
44
40
38
35

95
74
62
52
45
40
35
31
28
25
23

95
69
54
44
36
31
26
23
20
18
16

95
64
47
37
30
24
20
17
15
13
11

89
75
65
58
53
48
44
40
37
35
32

89
69
57
48
42
37
32
29
26
24
22

89
64
50
41
34
29
25
21
19
17
15

89
59
44
34
28
23
19
16
14
12
11

77
59
49
41
35
31
27
24
22
20
18

77
55
43
35
29
24
21
18
16
14
13

77
51
38
30
24
19
16
14
12
10
9

67
50
41
34
29
26
23
20
18
17
15

67
47
36
29
24
20
17
15
13
12
11

67
44
32
25
20
16
13
11
10
8
7

57
42
33
28
24
21
18
16
15
14
13

57
39
30
24
19
16
14
12
11
10
9

57
37
27
20
16
13
11
9
8
7
6

53
33
23
17
13
10
8
7
6
5
4

Zonal Lumen Summary
Zone
0-30
0-40
0-60
0-90

Lumens
525.75
1136.81
3406.12
8463.75

% Lamp
3.3
7.1
21.3
52.9

% Fixture
3.8
8.3
24.7
61.4

Zone
90-120
90-130
90-150
90-180
0-180

Lumens
4858.16
5299.62
5312.56
5313.30
13777.05

% Lamp
30.4
33.1
33.2
33.2
86.1

% Fixture
35.3
38.5
38.5
38.6
100.0

REPORT NUMBER: LP15LST
150 W High Pressure Sodium fixture with Standard Dome Reflector *
Coefficients of Utilization - Zonal Cavity Method
Effective Floor Cavity Reflectance 0.20
% Ceiling Rcc
% Walls Rw

Zone
0-10
10-20
20-30
30-40
40-50
50-60
60-70
70-80
80-90
90-100
100-110
110-120

30

50

110-120 1379.11
120-130
130-140
140-150
150-160
160-170
170-180

50

70

0
1
2
3
4
5
6
7
8
9
10

80

70

50

30

10

0

70

50

30

10

70

50

30

10

50

30

10

50

30

10

50

30

10

0

88
79
71
64
58
53
49
45
42
39
36

88
76
65
56
49
43
38
34
31
28
26

88
72
59
49
42
36
31
27
24
22
20

88
69
55
44
36
31
26
23
20
18
16

86
77
69
62
57
52
47
44
40
38
35

86
74
63
55
48
42
38
34
31
28
26

86
71
58
49
41
35
31
27
24
22
20

86
68
54
44
36
30
26
23
20
18
16

82
71
61
52
46
40
36
33
30
27
25

82
68
57
47
40
35
30
27
24
21
19

82
66
53
43
36
30
26
22
20
17
16

78
68
58
50
44
39
35
31
29
26
24

78
66
55
46
39
34
30
26
23
21
19

78
64
52
42
35
30
25
22
19
17
16

75
65
56
48
42
38
34
30
28
25
23

75
64
53
45
38
33
29
26
23
21
19

75
62
50
41
35
29
25
22
19
17
15

73
60
49
40
33
28
24
20
18
16
14

Zonal Lumen Summary
Zone
0-30
0-40
0-60
0-90

Lumens
2403.44
4135.50
8520.70
11743.37

% Lamp
15.0
25.8
53.3
73.4

% Fixture
20.4
35.1
72.3
99.7

Zone
90-120
90-130
90-150
90-180
0-180

Lumens
31.14
35.65
38.29
38.29
11781.65

% Lamp
0.2
0.2
0.2
0.3
73.6

% Fixture
0.3
0.3
0.3
0.3
100.0

Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

Mercmaster™ II HID Luminaire Photometric Data
150 W HPS

UNILETS® for Use with Threaded Metal Conduit.
* Photometric data is based on fixtures with
150-watt clear High Pressure Sodium lamp
(16,000 lumen).

Total Luminaire Efficiency = 73.1%
CIE Type - Direct
Plane

Spacing
Criteria
2.06

90-270

1.58

Diagonal

1.62

REPORT NUMBER: LP15LAN
150 W High Pressure Sodium fixture with 30° Angle Dome Reflector *
Coefficients of Utilization - Zonal Cavity Method
Effective Floor Cavity Reflectance 0.20
% Ceiling Rcc
% Walls Rw

Lumens
222.62
664.60
1084.32
1536.55
1771.90
1771.51
1668.93
1422.36
994.54
432.23
104.58
20.99

120-130
130-140
140-150
150-160
160-170
170-180

1.21
0.04
0.00
0.00
0.00
0.00

Total Luminaire Efficiency = 81.1%
CIE Type - Semi-Direct
Plane

Spacing
Criteria

0-180

1.98

90-270

1.98

Diagonal

3.40

0
1
2
3
4
5
6
7
8
9
10

Lumens
72.83
222.26
380.73
621.11
852.53
1765.29
3192.58
2366.61
1230.65
450.14
712.41
499.15

120-130
130-140
140-150
150-160
160-170
170-180

323.44
185.00
81.31
21.08
2.81
0.00

70

50

30

10

0

70

50

30

10

70

50

30

10

50

30

10

50

30

10

50

30

10

0

86
76
68
61
55
50
46
43
40
37
35

86
71
60
52
45
40
36
32
29
26
24

86
67
54
45
38
33
28
25
22
20
18

86
63
49
39
32
27
23
20
18
16
14

84
73
65
59
53
49
45
41
38
36
33

84
69
58
50
44
39
35
31
28
26
24

84
65
53
44
37
32
28
25
22
20
18

84
62
48
39
32
27
23
20
17
16
14

79
65
55
48
42
37
33
30
27
25
23

79
62
50
42
36
31
27
24
21
19
17

79
59
46
37
31
26
22
19
17
15
14

75
62
52
45
39
35
31
28
26
24
22

75
59
48
40
34
30
26
23
21
19
17

75
57
45
36
30
25
22
19
17
15
13

71
58
49
43
37
33
30
27
25
23
21

71
56
46
39
33
29
25
22
20
18
16

71
54
43
35
29
25
21
19
16
15
13

70
52
41
33
27
23
20
17
15
13
12

Zonal Lumen Summary
Zone
0-30
0-40
0-60
0-90

Lumens
1971.54
3508.09
7051.50
11137.33

% Lamp
12.3
21.9
44.1
69.6

% Fixture
16.9
30.0
60.3
95.2

Zone
90-120
90-130
90-150
90-180
0-180

Lumens
557.80
559.01
559.04
559.04
11696.38

% Lamp
3.5
3.5
3.5
3.5
73.1

% Fixture
4.8
4.8
4.8
4.8
100.0

REPORT NUMBER: LP15LJ
150 W High Pressure Sodium fixture with
8” Prismatic Glass Reractor - NEMA Type V *
Coefficients of Utilization - Zonal Cavity Method
Effective Floor Cavity Reflectance 0.20
% Ceiling Rcc
% Walls Rw

Zone
0-10
10-20
20-30
30-40
40-50
50-60
60-70
70-80
80-90
90-100
100-110
110-120

80

0
1
2
3
4
5
6
7
8
9
10

80

70

50

30

10

0

70

50

30

10

70

50

30

10

50

30

10

50

30

10

50

30

10

0

93
80
69
61
54
49
45
41
38
35
33

93
73
59
49
42
36
32
28
25
23
21

93
68
51
40
32
27
23
20
17
15
14

93
63
45
33
25
20
16
14
12
10
9

89
76
65
57
51
46
42
38
36
33
31

89
70
56
47
40
34
30
27
24
22
20

89
65
49
38
31
26
22
19
16
15
13

89
61
43
32
24
19
16
13
11
10
9

82
64
51
42
35
31
27
24
22
20
18

82
60
45
35
28
23
20
17
15
13
12

82
56
40
29
22
18
14
12
10
9
8

76
58
46
38
32
27
24
24
19
18
16

76
55
41
32
26
21
18
15
14
12
11

76
52
37
27
21
16
13
11
9
8
7

70
53
41
34
28
24
21
19
17
16
15

70
50
37
29
23
19
16
14
12
11
10

70
48
34
25
19
15
12
10
8
7
6

67
45
31
22
16
12
10
8
6
5
5

Zonal Lumen Summary
Zone
0-30
0-40
0-60
0-90

Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

Lumens
675.83
1296.93
3914.76
10704.60

% Lamp
4.2
8.1
24.5
66.9

% Fixture
5.2
10.0
30.2
82.5

Zone
90-120
90-130
90-150
90-180
0-180

Lumens
1661.70
1985.14
2251.45
2275.34
12979.94

% Lamp
10.4
12.4
14.1
14.2
81.1

% Fixture
12.8
15.3
15.3
17.5
100.0

1017

Lighting: Enclosed and Gasketed — Area — HID

Zone
0-10
10-20
20-30
30-40
40-50
50-60
60-70
70-80
80-90
90-100
100-110
110-120

Lighting

0-180

For candlepower values of fixtures with other
HPS lamps, use the following multipliers; for
100 W (9,500 lumen) HPS lamp – 0.594; for 70 W
(6,400 lumen) HPS lamp – 0.40; for 50 W (4,000
lumen) HPS lamp – 0.25. For candlepower
values of fixture with guard, multiply by 0.95.

Mercmaster™ II HID Luminaire Photometric Data
175 W PSMH

UNILETS® for Use with Threaded Metal Conduit.
* Photometric data is based on fixtures with
175-watt clear Pulse Start Metal Halide lamp
(17,500 lumen).

Total Luminaire Efficiency = 75.4%
CIE Type - General Diffuse

Lighting

Plane

Spacing
Criteria

0-180

n/a

90-270

n/a

Diagonal

n/a

For candlepower values of fixtures with other
PSMH lamps, use the following multipliers:
for 250 W (23,750 lumen) PSMH lamp – 1.36;
for 100 W (8,500 lumen) PSMH lamp – 0.49.
For candlepower values of fixture with guard,
multiply by 0.95.

REPORT NUMBER: LP17PGG
175 W Pulse Start Metal Halide fixture with Globe only *
Coefficients of Utilization - Zonal Cavity Method
Effective Floor Cavity Reflectance 0.20
% Ceiling Rcc

Lighting: Enclosed and Gasketed — Area — HID

% Walls
Zone
0-10
10-20
20-30
30-40
40-50
50-60
60-70
70-80
80-90
90-100
100-110

Lumens
42.67
151.27
305.99
587.79
880.58
1114.51
1306.71
1568.03
1720.24
1797.50
1750.20

110-120

1559.14

120-130
130-140
140-150
150-160
160-170
170-180

391.09
7.81
3.19
0.61
0.18
0.00

Total Luminaire Efficiency = 63.8%
CIE Type - Direct
Plane

Spacing
Criteria

0-180

1.50

90-270

1.50

Diagonal

1.66

0
1
2
3
4
5
6
7
8
9
10

Lumens
271.72
817.50
1392.53
1749.97
2044.83
2121.25
1862.42
720.46
141.89
14.66
8.28
9.57

120-130
130-140
140-150
150-160
160-170
170-180

5.69
3.14
2.17
1.71
1.70
0.36

1018

70

50

30

10

0

70

50

30

10

70

50

30

10

50

30

10

50

30

10

50

30

10

0

82
70
62
55
50
46
42
38
35
33
31

82
65
54
46
40
35
31
27
25
22
20

82
60
47
38
32
27
23
20
18
16
14

82
55
42
33
26
22
18
15
13
12
10

77
65
57
51
46
42
38
35
32
30
28

77
60
50
42
37
32
28
25
23
21
19

77
56
44
36
30
25
22
19
17
15
13

77
52
39
30
24
20
17
14
12
11
9

66
51
42
35
31
27
24
21
19
17
16

66
47
37
30
25
21
18
16
14
13
11

66
44
33
26
21
17
14
12
10
9
8

57
42
35
29
25
22
20
18
16
14
13

57
40
31
25
21
17
15
13
12
10
9

57
37
28
21
17
14
12
10
9
7
7

48
35
28
23
20
17
15
14
13
12
11

48
33
25
20
16
14
12
10
9
8
7

48
31
22
17
13
11
9
8
7
6
5

44
27
19
14
11
8
7
6
5
4
3

Zonal Lumen Summary
Zone
0-30
0-40
0-60
0-90

Lumens
499.93
1087.72
3082.80
7677.78

% Lamp
2.9
6.2
17.6
43.9

% Fixture
3.8
8.2
23.4
58.2

Zone
90-120
90-130
90-150
90-180
0-180

Lumens
5106.84
5497.93
5508.93
5509.71
13187.48.

% Lamp
29.2
31.4
31.5
31.5
75.4

% Fixture
38.7
41.7
41.7
41.8
100.0

REPORT NUMBER: LP17PST
175 W Pulse Start Metal Halide fixture with Standard Dome Reflector *
Coefficients of Utilization - Zonal Cavity Method
Effective Floor Cavity Reflectance 0.20
% Ceiling Rcc
% Walls

Zone
0-10
10-20
20-30
30-40
40-50
50-60
60-70
70-80
80-90
90-100
100-110
110-120

Rw

80

Rw
0
1
2
3
4
5
6
7
8
9
10

80

70

50

30

10

0

70

50

30

10

70

50

30

10

50

30

10

50

30

10

50

30

10

0

76
69
62
56
51
47
43
40
37
34
32

76
66
57
49
43
38
34
31
28
25
23

76
63
52
44
37
32
28
25
22
20
18

76
61
48
39
33
28
24
21
18
16
15

74
67
61
55
50
45
42
39
36
33
31

74
65
56
48
42
37
33
30
27
25
23

74
62
51
43
37
32
28
25
22
20
18

74
60
48
39
33
28
24
21
18
16
15

71
62
53
46
41
36
32
29
26
24
22

71
60
50
42
36
31
27
24
22
19
18

71
58
47
38
32
27
23
20
18
16
14

68
59
51
45
39
35
31
28
26
23
22

68
57
48
41
35
30
27
24
21
19
17

68
56
46
38
32
27
23
20
18
16
14

65
57
49
43
38
33
30
27
25
23
21

65
55
47
40
34
30
26
23
21
19
17

65
54
45
37
31
27
23
20
18
16
14

64
53
43
35
30
25
22
19
16
15
13

Zonal Lumen Summary
Zone
0-30
0-40
0-60
0-90

Lumens
2481.75
4231.72
8397.80
11122.57

% Lamp
14.2
24.2
48.0
63.6

% Fixture
22.2
37.9
75.2
99.6

Zone
90-120
90-130
90-150
90-180
0-180

Lumens
32.51
38.20
43.51
47.28
11169.85

% Lamp
0.2
0.2
0.2
0.3
63.8

% Fixture
0.3
0.3
0.3
0.4
100.0

Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

Mercmaster™ II HID Luminaire Photometric Data
175 W PSMH

UNILETS® for Use with Threaded Metal Conduit.
* Photometric data is based on fixtures with
175-watt clear Pulse Start Metal Halide lamp
(17,500 lumen).

Total Luminaire Efficiency = 61.6%
CIE Type - Direct
Plane

Spacing
Criteria
2.02

90-270

1.62

Diagonal

1.58

REPORT NUMBER: LP17PAN
175 W Pulse Start Metal Halide fixture with 30° Angle Dome Reflector *
Coefficients of Utilization - Zonal Cavity Method
Effective Floor Cavity Reflectance 0.20
% Ceiling Rcc
% Walls

Lumens
221.01
674.48
1111.79
1519.14
1697.13
1644.77
1457.83
1248.84
814.94
280.33
87.54
16.66

120-130
130-140
140-150
150-160
160-170
170-180

1.25
0.06
0.06
0.00
0.00
0.00

Total Luminaire Efficiency = 73.9%
CIE Type - Semi-Direct
Plane

Spacing
Criteria

0-180

2.08

90-270

2.08

Diagonal

3.78

0
1
2
3
4
5
6
7
8
9
10

Lumens
58.60
179.87
316.74
543.99
726.99
1445.41
3661.34
2432.42
1351.63
477.79
717.26
474.07

120-130
130-140
140-150
150-160
160-170
170-180

293.44
163.08
70.40
18.48
2.58
0.00

70

50

30

10

0

70

50

30

10

70

50

30

10

50

30

10

50

30

10

50

30

10

0

73
64
58
52
47
43
40
37
34
32
30

73
61
52
45
39
34
31
28
25
23
21

73
57
46
39
33
28
25
22
20
18
16

73
54
42
34
28
24
20
18
16
14
13

71
62
56
50
46
42
38
35
33
31
29

71
59
50
43
38
34
30
27
25
23
21

71
56
45
38
32
28
24
22
19
17
16

71
53
42
34
28
24
20
18
16
14
12

67
56
47
41
36
32
29
26
24
22
20

67
53
44
36
31
27
24
21
19
17
15

67
51
40
33
27
23
20
17
15
14
12

64
53
45
39
34
30
27
25
23
21
19

64
51
42
35
30
26
23
20
18
17
15

64
49
39
32
27
23
20
17
15
13
12

61
50
43
37
33
29
26
24
22
20
18

61
49
40
34
29
25
22
20
18
16
15

61
47
38
31
26
22
19
17
15
13
12

59
45
36
29
24
21
18
15
14
12
11

Zonal Lumen Summary
Zone
0-30
0-40
0-60
0-90

Lumens
2007.28
3526.41
6868.32
10389.94

% Lamp
11.5
20.2
39.2
59.4

% Fixture
18.6
32.7
63.7
96.4

Zone
90-120
90-130
90-150
90-180
0-180

Lumens
384.53
385.77
385.89
385.89
10775.83

% Lamp
2.2
2.2
2.2
2.2
61.6

% Fixture
3.6
3.6
3.6
3.6
100.0

REPORT NUMBER: LP17PJ
175 W Pulse Start Metal Halide fixture with Globe and
8” Prismatic Glass Reractor - NEMA Type V *
Coefficients of Utilization - Zonal Cavity Method
Effective Floor Cavity Reflectance 0.20
% Ceiling Rcc
% Walls

Zone
0-10
10-20
20-30
30-40
40-50
50-60
60-70
70-80
80-90
90-100
100-110
110-120

Rw

80

Rw
0
1
2
3
4
5
6
7
8
9
10

80

70

50

30

10

0

70

50

30

10

70

50

30

10

50

30

10

50

30

10

50

30

10

0

85
72
62
55
49
44
40
37
34
31
29

85
66
53
44
37
32
28
25
22
20
18

85
61
46
35
28
23
20
17
15
13
12

85
56
39
29
22
17
14
12
10
8
7

82
68
59
51
46
41
37
34
32
30
28

82
63
51
41
35
30
26
23
21
19
18

82
58
44
34
27
22
19
16
14
13
11

82
54
38
28
21
16
13
11
9
8
7

75
57
46
37
31
27
24
21
19
17
16

75
54
40
31
24
20
17
15
13
11
10

75
50
35
25
19
15
12
10
8
7
6

69
52
41
33
28
24
21
19
17
16
14

69
49
36
28
22
18
15
13
12
10
9

69
46
32
23
17
14
11
9
8
7
6

64
47
37
30
25
21
19
17
15
14
13

64
45
33
25
20
16
14
12
10
9
8

64
43
30
21
16
12
10
8
7
6
5

61
40
27
19
13
10
8
6
5
4
4

Zonal Lumen Summary
Zone
0-30
0-40
0-60
0-90

Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

Lumens
555.22
1099.21
3271.60
10717.00

% Lamp
3.2
6.3
18.7
61.2

% Fixture
4.3
8.5
25.3
82.9

Zone
90-120
90-130
90-150
90-180
0-180

Lumens
1669.13
1962.57
2196.06
2217.10
12934.11

% Lamp
9.5
11.2
12.5
12.7
73.9

% Fixture
12.9
15.2
15.2
17.1
100.0

1019

Lighting: Enclosed and Gasketed — Area — HID

Zone
0-10
10-20
20-30
30-40
40-50
50-60
60-70
70-80
80-90
90-100
100-110
110-120

Lighting

0-180

For candlepower values of fixtures with other
PSMH lamps, use the following multipliers:
for 250 W (23,750 lumen) PSMH lamp – 1.36;
for 100 W (8,500 lumen) PSMH lamp – 0.49.
For candlepower values of fixture with guard,
multiply by 0.95.

Mercmaster™ II HID Luminaire Isofootcandle Data

High Pressure Sodium and Pulse Start Metal Halide. Mogul Base
UNILETS® for Use with Threaded Metal Conduit.

Lighting

HPS Lamp
Wattage

Horizontal Distance from Mounting Point (Ft/M)

Mounting Height
(Ft/M)

0/0
5/1.5
10/3.0
15/4.6
Mercmaster II, High Pressure Sodium, No Reflector, No Guard
70 Watt – 5,800 Lumen
100 Watt – 9,500 Lumen
150 Watt – 16,000 Lumen

20/6.1

25/7.6

30/9.1

35/10.7

40/12.2

45/13.7

50/15.2

Lighting: Enclosed and Gasketed — Area — HID

Footcandle Chart (Initial Horiz. FTC)

70

100

150

8/2.4

.60

2.70

1.50

.73

.38

.21

.13

.08

.06

.04

.03

10/3.0

.39

1.70

1.30

.72

.40

.24

.15

.10

.07

.05

.04

12/3.7

.27

1.10

1.10

.68

.41

.26

.17

.11

.08

.06

.04

15/4.6

.17

.66

.81

.60

.39

.26

.18

.13

.09

.07

.05

20/6.1

.10

.37

.43

.40

.33

.25

.18

.13

.10

.08

.06

8/2.4

1.00

4.80

2.70

1.20

.62

.35

.21

.14

.10

.07

.05

10/3.0

.64

2.80

2.20

1.30

.67

.40

.25

.16

.11

.08

.06

12/3.7

.44

1.80

1.80

1.30

.71

.42

.28

.18

.13

.09

.07

15/4.6

.28

1.10

1.30

.97

.70

.45

.30

.21

.15

.11

.08

20/6.1

.16

.59

.69

.70

.55

.42

.32

.23

.17

.13

.10

8/2.4

2.50

8.30

4.60

2.20

1.10

.62

.38

.25

.17

.12

.09

10/3.0

1.60

5.40

4.00

2.20

1.20

.71

.44

.29

.20

.14

.11

12/3.7

1.10

4.20

3.30

2.00

1.20

.76

.49

.33

.23

.17

.12

15/4.6

.72

2.10

2.40

1.80

1.20

.79

.54

.38

.27

.20

.15

20/6.1

.40

1.10

1.30

1.30

1.00

.73

.54

.40

.30

.23

.18

Mercmaster II, High Pressure Sodium, With Reflector, No Guard
70 Watt – 5,800 Lumen
100 Watt – 9,500 Lumen
150 Watt – 16,000 Lumen
Footcandle Chart (Initial Horiz. FTC)

70

100

150

1020

8/2.4

14.80

10.00

3.80

1.50

.55

.15

.05

.03

.02

.01

.01

10/3.0

9.50

7.70

3.70

1.60

.74

.32

.12

.05

.03

.02

.01

12/3.7

6.60

6.60

3.30

1.50

.87

.46

.18

.10

.05

.02

.02

15/4.6

4.20

4.20

2.70

1.70

.94

.56

.33

.18

.10

.06

.03

20/6.1

2.40

2.50

1.90

1.30

.92

.62

.41

.28

.18

.12

.08

8/2.4

21.90

16.80

6.30

2.40

.86

.28

.08

.05

.03

.02

.01

10/3.0

14.00

12.40

6.00

2.70

1.20

.53

.19

.07

.04

.03

.02

12/3.7

9.70

9.40

5.50

2.80

1.40

.73

.36

.20

.13

.04

.03

15/4.6

6.20

6.70

4.40

2.70

1.60

.90

.53

.33

.19

.11

.05

20/6.1

3.50

4.30

3.10

2.20

1.50

1.0

.68

.44

.30

.21

.13

8/2.4

36.90

27.80

10.50

3.80

1.30

.35

.14

.08

.04

.03

.02

10/3.0

23.60

20.80

10.10

4.40

2.00

.78

.29

.11

.07

.04

.03

12/3.7

16.40

15.80

9.20

4.60

2.20

1.20

.54

.30

.16

.06

.04

15/4.6

10.50

11.60

7.50

4.50

2.60

1.50

.86

.42

.26

.16

.08

20/6.1

5.90

7.20

5.20

3.70

2.50

1.70

1.10

.73

.50

.32

.19

Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

Mercmaster™ Jr. Luminaires

High Pressure Sodium. Suitable for Use in Wet Locations

UNILETS® for Use with Threaded Metal Conduit. 120 V Integral Ballast. Medium Base Socket for Medium Base Lamps.
With Globe:
70 W: † 
35 W, 50 W: † 
Class I, Division 2, Groups A, B, C, D
Class I, Division 2, Groups A, B, C, D
Class II, Division 1 and 2, Groups E ‡, F
Class II, Division 1 and 2, Groups E ‡, F, G
Class III
100 W, 150 W: †  
Class I, Division 2, Groups A, B, C, D

With Refractor (NEMA V):
150 W: †
35 W, 50 W, 70 W, 100 W: † 
Class I, Division 2, Groups A, B, C, D
Class I, Division 2, Groups A, B, C, D
Class II, Division 1 and 2, Groups E ‡, F, G
Class III

Applications

Lighting

•	 Inexpensive HID integrally ballasted fixture for use in hazardous
locations – inexpensive to buy and inexpensive to operate (uses
one-fifth as much electrical energy as incandescent and threequarters as much as fluorescent).
•	 Enclosed and gasketed HID lighting fixtures for use in tunnels,
walkways, bridges, storage facilities, processing plants, parking
lots, foundries, manufacturing plants, power plants and other
locations where moisture, dirt, dust or corrosive atmospheres
are encountered.

Features

Lighting: Enclosed and Gasketed — Area — HID

•	 “Wireless” design. Threading of fixture unit onto mounting hood
makes electrical connection. Only wiring required is attaching
two wires to connection block in mounting hood.
•	 Safe, easy servicing without disconnecting any wiring.
“Wireless” fixture unit easily threads off mounting hood for
convenient servicing.
•	 Quick, easy conversion from Appleton V-51® incandescent
installation to Mercmaster Jr. HID. Just remove V-51® fixture
unit and thread Mercmaster Jr. fixture unit onto existing V-51®
mounting hood.
•	 Choice of mounting hoods. Standard fixtures in pendant, ceiling,
outlet box, wall and stanchion mountings.
•	 Standard pendant mounting hood for rigid or flexible mounting.
Balanced round design automatically hangs plumb when used
with flexible hanger.
•	 Unitized construction reduces installation and maintenance
costs.
•	 Ballast has standard non-PCB biodegradable capacitors.
•	 Medium base socket is furnished with 392 °F/200 °C leads,
prewired to the ballast. Porcelain socket assures trouble-free
operation in high ambient installations.
•	 Prismatic glass globe or glass refractor is standard and threads
directly into fixture housing. Eliminates glare and provides
uniform light distribution.
•	 Fiberglass reinforced polyester reflector for exceptionally severe
corrosive atmospheres. Vented for cooler, dirt-free operation,
increased lumen output.

Illustrated Feature
Conversion from Appleton V-51 incandescent installation to
HID Mercmaster Jr. is easy and fast.

Step No. 1:
After power is shut off, remove present
incandescent V-51 fixture unit from
existing V-51 mounting hood.

Standard Materials
Step No. 2:
Thread Mercmaster Jr. HID fixture unit
onto existing V-51 mounting hood —
and conversion is completed.

•	 Mounting hoods: copperfree (4/10 of 1% max.) aluminum or
malleable iron
•	 Ballast bodies: copperfree (4/10 of 1% max.) aluminum
•	 Guards: copperfree (4/10 of 1% max.) aluminum or steel
•	 Reflectors: fiberglass reinforced polyester or porcelain
•	 Globe: 35 W-100 W, threaded prismatic glass and threaded
polycarbonate; 150 W, threaded heat-resistant prismatic glass
•	 Refractor: heat-resistant prismatic glass

Standard Finishes
•	 Ballast bodies, aluminum guard and VMA, VXHA-A, OBVW1-A,
OBV1-A, JBW1-A, JB1-A, GSW2 and MS mounting hoods:
epoxy powder coat finish, electrostatically applied for complete,
uniform surface protection
•	 VA, VXHA, OBVW1, OBV1, GS-2, JBW1, and JB1 malleable iron
mounting hoods: triple coat – (1) zinc electroplate; (2) chromate;
and (3) epoxy powder coat
•	 Steel guard: zinc electroplate

Options
•	 Fuses for fixtures, factory installed. Add suffix -F.

Certifications and Compliances
•	 UL Standard: UL 1598, UL 1598A, UL 844
•	 UL Listed: E10444

† The MJBW Wall Mount Fixture is suitable for Class I, Division 2, Groups A, B, C and D only.
‡ Per NEC 500.6(1), there is no such classification as Class II, Division 2, Group E.
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

1021

Mercmaster™ Jr. Luminaire Classified Area Suitability and Ballast Data
High Pressure Sodium. Suitable for Use in Wet Locations

UNILETS® for Use with Threaded Metal Conduit. 120 V Integral Ballast. Medium Base Socket for Medium Base Lamps.

Lighting: Enclosed and Gasketed — Area — HID

Lighting

With Globe:
70 W: † 
35 W, 50 W: † 
Class I, Division 2, Groups A, B, C, D
Class I, Division 2, Groups A, B, C, D
Class II, Division 1 and 2, Groups E ‡, F
Class II, Division 1 and 2, Groups E ‡, F, G
Class III
100 W, 150 W: †  
Class I, Division 2, Groups A, B, C, D

With Refractor (NEMA V):
150 W: †
35 W, 50 W, 70 W, 100 W: † 
Class I, Division 2, Groups A, B, C, D
Class I, Division 2, Groups A, B, C, D
Class II, Division 1 and 2, Groups E ‡, F, G
Class III

Thermal Suitability
Table at below shows maximum operating temperatures of
Mercmaster Jr. fixtures for Class I, Division 2, in a 104 °F/40
°C ambient. Per NEC 500.8(B)(4), the temperature marking on
fixtures shall not exceed the ignition temperature of the specific
gas or vapor to be encountered. NEC 500.8(B)(4) states that
these markings (Identification Numbers) “marked on equipment
nameplates shall be in accordance with Table NEC 500.8(C).” This
NEC table is duplicated, as it applies to Appleton Mercmaster Jr.
fixtures, in the table below.
As shown, the higher the Temperature Identification Number, the
cooler the fixture operates. Keep this in mind when selecting a
fixture for a specific gas or vapor.

Example:
• Gasoline (56-60 octane)
• Fixture with Globe and Reflector
To determine Mercmaster Jr. thermal suitability for the above
example:
(1) Check the Thermal Suitability on the following page for ignition
temperature of gas or vapor to be encountered. It reveals that
56-60 octane gasoline has an ignition temperature of 	
536 °F/280 °C.
(2) Look in table below for fixtures under “With Globe and
Reflector” that do not exceed the 536 °F/280 °C ignition
temperature of the gasoline.
(3) Select the best fixture for your purpose. The 35 W, 50 W, 70 W
or 100 W fixture with globe and reflector is acceptable because
none of these fixture lamp surfaces exceed the 536 °F/280 °C
ignition temperature of the gasoline.

Temperature Identification Numbers
Class I, Division 2, Groups A, B, C and D
With Globe or with Globe and Reflector
Lamp
Watts

Class II, Division 1 and 2, Groups E, F and G

With 8” Refractor

With Globe, with Globe and Reflector, or with 8” Refractor

Nameplate
Marking

Temperature
Range (°F/°C)

Nameplate
Marking

Temperature
Range (°F/°C)

Nameplate
Marking

Temperature
Range (°F/°C)

Groups

35

T4

250-275 / 121-135

T4

250-275 / 121-135

T4C

214-248 / 101-120

E, F, G

50

T2D

394-419 / 201-215

T3

358-392 / 181-200

T3C

277-320 / 136-160

E, F, G

70

T2B

448-500 / 231-260

T2C

421-446 / 216-230

T3B

322-329 / 161-165

E, F, G ➊

100

T2A

502-536 / 261-280

T2B

448-500 / 231-260

—

—

E, F, G ➋

150

T2

538-572 / 281-300

T2A

502-536 / 261-280

—

—

—

Ambient Suitability of Mercmaster Jr. Fixtures

Electrical Specifications (Reactor Ballasts)

All fixtures suitable for operation at -40 °F/-40 °C.

35W

50W

70W

100W

150W

104 °F/	
40 °C

104 °F/	
40 °C

77 °F/	
25 °C

77 °F/	
25 °C

77 °F/	
25 °C

Retrofits Incandescent Fixtures Easily and Quickly
•	
•	
•	
•	
•	

35 W HPS Comparable to 100/150 W Incandescent Lamp
50 W HPS Comparable to 200 W Incandescent Lamp
70 W HPS Comparable to 300 W Incandescent Lamp
100 W HPS Comparable to 1.5 300 W Incandescent Lamp ➌
150 W HPS Comparable to 2.5 300 W Incandescent Lamp ➌

Lamp
Watts

Line Voltage
60 Hz

Line Current in Amperes
Starting HPF Operating HPF

Input
Watts

35

120

0.41

0.38

43

50

120

0.62

0.56

60

70

120

0.70

0.73

82

100

120

1.10

1.00

115

150

120

1.70

1.50

170

Optional Factory-Installed Fuses – Add Suffix -F
Available as a factory installed item with Mercmaster Jr. fixtures.

➊70W suitable for Groups E and F with globe; suitable for Groups E, F, and G with refractor.
➋ 100W suitable for Groups E, F and G with refractor only.
➌ These are guidelines only. Light distribution and other factors must be taken into consideration.
† The MJBW Wall Mount Fixture is suitable for Class I, Division 2, Groups A, B, C and D only.
‡ Per NEC 500.6(1), there is no such classification as Class II, Division 2, Group E.

1022

Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

Mercmaster™ Jr. Luminaires

35 W, 50 W, 70 W, 100 W, 150 W HPS

Complete with Mounting Hood. Medium Base Socket. High Power Factor (Min. P.F. 90%). Integral Ballast for 120 V Line Operation.
With Globe:
70 W: † 
35 W, 50 W: † 
Class I, Division 2, Groups A, B, C, D
Class I, Division 2, Groups A, B, C, D
Class II, Division 1 and 2, Groups E ‡, F
Class II, Division 1 and 2, Groups E ‡, F, G
Class III
100 W, 150 W: †  
Class I, Division 2, Groups A, B, C, D

With Refractor (NEMA V):
150 W: †
35 W, 50 W, 70 W, 100 W: † 
Class I, Division 2, Groups A, B, C, D
Class I, Division 2, Groups A, B, C, D
Class II, Division 1 and 2, Groups E ‡, F, G
Class III

S76
S68
S62
S54
S55

—
—
—
—
—

MGSW35-120
MGSW50-120
MGSW70-120
MGSW10-120
MGSW15-120

MGSW35J-120
MGSW50J-120
MGSW70J-120
MGSW10J-120
MGSW15J-120

Wall ➋➌ — Class I, Division 2 only. Aluminum mounting hood and ballast body. Gasket and screws furnished with fixture. Fits JBX Cast Boxes
35
50
70
100
150

S76
S68
S62
S54
S55

25° Stanchion ➍ — Aluminum mounting hood and ballast body. One hub
35

S76

50

S68

70

S62

100

S54

150

S55

—
—
—
—
—

MJBW35-120
MJBW50-120
MJBW70-120
MJBW10-120
MJBW15-120

MJBW35J-120
MJBW50J-120
MJBW70J-120
MJBW10J-120
MJBW15J-120

1-1/4
1-1/2
1-1/4
1-1/2
1-1/2
1-1/2
1-1/4
1-1/2
1-1/4
1-1/2

MS35125-120
MS35150-120
MS50125-120
MS50150-120
MS70125-120
MS70150-120
MS10125-120
MS10150-120
MS15125-120
MS15150-120

MS35125J-120
MS35150J-120
MS50125J-120
MS50150J-120
MS70125J-120
MS70150J-120
MS10125J-120
MS10150J-120
MS15125J-120
MS15150J-120

‡ Per NEC 500.6(1), there is no such classification as Class II, Division 2, Group E.
† The MJBW Wall Mount Fixture is suitable for Class I, Division 2, Groups A, B, C and D only.
 All fixtures on this page comply with UL Standard 844 except MJBW Wall Mount Fixture, which is not suitable for Class II, Division 1.
 Using cast outlet box with Wall Mount Fixture provides the following clearances: for the globe – JBX box, 1-5/8” from wall; GSU box, 2” from wall; for the
refractor – JBX box, 15/16” from wall; GSW box, 1-5/16” from wall. Reflectors cannot be used with the wall mount fixtures.
 Stanchion Mount can be used with standard dome or 30° angle reflector.
 To order fixture with guard, add -G before voltage (example: MA3575G-120).
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

1023

Lighting: Enclosed and Gasketed — Area — HID

35
50
70
100
150

Lighting

Catalog Number ➎
With Globe,
With Refractor
ANSI
Hub Size
Less Guard
(NEMA V)
Lamp Watts
Lamp Type
(Inches)
With Globe, Less Guard
With Refractor (NEMA V)
Pendant — Aluminum mounting hood and ballast body. One Hub, Rigid or Flexible Mounting
3/4
MA3575-120
MA3575J-120
35
S76
1
MA3510-120
MA3510J-120
3/4
MA5075-120
MA5075J-120
50
S68
1
MA5010-120
MA5010J-120
3/4
MA7075-120
MA7075J-120
70
S62
1
MA7010-120
MA7010J-120
3/4
MA1075-120
MA1075J-120
100
S54
1
MA1010-120
MA1010J-120
3/4
MA1575-120
MA1575J-120
150
S55
1
MA1510-120
MA1510J-120
Ceiling — Aluminum mounting hood and ballast body. Five Hubs, Four Close-Up Plugs
3/4
MC3575-120
MC3575J-120
35
S76
1
MC3510-120
MC3510J-120
3/4
MC5075-120
MC5075J-120
50
S68
1
MC5010-120
MC5010J-120
3/4
MC7075-120
MC7075J-120
70
S62
1
MC7010-120
MC7010J-120
3/4
MC1075-120
MC1075J-120
100
S54
1
MC1010-120
MC1010J-120
3/4
MC1575-120
MC1575J-120
150
S55
1
MC1510-120
MC1510J-120
Wall ➌ — Malleable iron mounting hood and aluminum ballast body. Gasket and screws furnished with fixture. Fits GSU Cast Boxes

Mercmaster™ Jr. Luminaires

High Pressure Sodium. Suitable for Use in Wet Locations

UNILETS® for Use with Threaded Metal Conduit. 120 V Integral Ballast. Medium Base Socket for Medium Base Lamps.
With Globe:
70 W: † 
35 W, 50 W: † 
Class I, Division 2, Groups A, B, C, D
Class I, Division 2, Groups A, B, C, D
Class II, Division 1 and 2, Groups E ‡, F
Class II, Division 1 and 2, Groups E ‡, F, G
Class III
100 W, 150 W: †  
Class I, Division 2, Groups A, B, C, D

With Globe

With 8” Refractor

With Refractor (NEMA V):
150 W: †
35 W, 50 W, 70 W, 100 W: † 
Class I, Division 2, Groups A, B, C, D
Class I, Division 2, Groups A, B, C, D
Class II, Division 1 and 2, Groups E ‡, F, G
Class III

Description

Catalog Number
With Globe ➊ With 8” Refractor

Lamp
Watts

ANSI
Lamp Type

35

S76

MOB35-120

MOB35J-120

50

S68

MOB50-120

MOB50J-120

70

S62

MOB70-120

MOB70J-120

100

S54

MOB10-120

MOB10J-120

150

S55

MOB15-120

MOB15J-120

Lamp
Watts

ANSI
Lamp Type

Catalog Number

S76

35

MUL35-120

S68

50

MUL50-120

S62

70

MUL70-120

S54

100

MUL100-120

S55

150

MUL150-120

S76

35

MBL35-120

S68

50

MBL50-120

S62

70

MBL70-120

S54

100

MBL100-120

S55

150

MBL150-120

Lighting

Outlet Box Fixture
Aluminum ballast housing, complete with
aluminum mounting hood. Epoxy clad.

Lighting: Enclosed and Gasketed — Area — HID

Use with SEH and 3-1/4” or 4” Octagonal
Outlet Box. Fixture furnished with mounting
plate and gasket. Octagonal boxes not
suitable for classified locations.

Fixture Units
Ballast body with globe (VPGL-1 with 35
W, 50 W, 70W and 100W and VPGL-1HR
with 150 W). Use with mounting hoods on
following page or any V-51 series mounting
hood. Polyester or porcelain reflector and
aluminum guard are available. High power
factor (min. P.F. 90%). Ballast provides 120 V
line operation.

Ballast Bodies
Use with mounting hoods on following
page or any V-51 series mounting hood and
with refractor or globe listed. Order other
accessories below as desired. High power
factor (min. P.F. 90%). Ballast provides 120 V
line operation.

‡ Per NEC 500.6(1), there is no such classification as Class II, Division 2, Group E.
† The MJBW Wall Mount Fixture is suitable for Class I, Division 2, Groups A, B, C and D only.
➊ Order JBX or GSU box on following page.

1024

Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

Mercmaster™ Jr. Luminaire Mounting Hoods and Outlet Boxes
High Pressure Sodium. Suitable for Use in Wet Locations

UNILETS® for Use with Threaded Metal Conduit. 120 V Integral Ballast. Medium Base Socket for Medium Base Lamps.

Wall

Ceiling

Catalog Number

Hub Size
(Inches)

Aluminum

1/2

—

Malleable Iron

Pendant Mounting Furnished with connection block, gasket and screws

VA

Lighting

VMA

VA50

3/4

VMA75

VA75

1

VMA100

VA100

1/2

VXHA50-A

VXHA50

3/4

VXHA75-A

VXHA75

1

VXHA100-A

VXHA100

Ceiling Mounting Five Hubs. Furnished with connection block, gasket, screws and four close-up plugs

Wall ➎

OBVW1-A

OBVW1

Ceiling

OBV1-A

OBV1

OBV

OBVW

GS Round Base – Fits GSU Cast Boxes ➌ ➍ Furnished with connection block, gasket and screws

GS

GSW

Wall ➎

—

GSW2

Ceiling

—

GS2

JB Round Base – Fits JBX Cast Boxes ➌ ➍ Furnished with connection block, gasket and screws

JB

JBW

Wall ➎

JBW1-A

JBW1

Ceiling

JB1-A

JB1

Stanchion Mounting ➏ 25° Stanchion furnished with connection block and screws.
1-1/4

MS-125

—

1-1/2

MS-150

—

1/2

JBX50L-A

—

3/4

JBX75L-A

—

MS
JBX Cast Conduit Outlet Boxes 

JBX

Aluminum. 1-5/16” inside depth. Four tapped openings,
two close-up plugs and mounting lugs. Use with JBW
wall mount fixture  and JB round base mounting hoods

GSU Cast Conduit Outlet Box (Form 20) 

GSU-20

GSU-100

Malleable iron. 1-3/4” inside depth. Four 3/4” hubs
with four 3/4” to 1/2” reducers, and three 1/2” close-up
plugs. Use with GSW wall mount fixture and GS round
base mounting hoods

1/2 or 3/4

—

GSU-20

1

—

GSU-100

 Order SEH box from catalog section A and octagonal box from Section OB. To order fixture with guard, add G before voltage (example: MOB35G-120).
 Order JBX below. Using JBX Box with these fixtures and mounting hoods provides 15/16” clearance from wall with refractor and 1-5/8” clearance from wall
with globe.
 Order GSU below. Using GSU Box with these fixtures and mounting hoods provides 1-5/16” clearance from wall with refractor and 2” clearance from wall with
globe.
 Reflectors cannot be used with wall mount fixtures. See dimensions for globe or refractor clearance from wall for these fixtures.
➏ Stanchion mounting hood can be used with standard dome or 30° angle reflector.
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

1025

Lighting: Enclosed and Gasketed — Area — HID

VXHA

Cast/Outlet Box Mounting Furnished with connection block, mounting plate and gasket. Octagonal outlet box not suitable for classified
locations. Fits SEH and 3-1/4” or 4” Octagonal Box ➋

Mercmaster™ Jr. Luminaire Accessories

High Pressure Sodium. Suitable for Use in Wet Locations

UNILETS® for Use with Threaded Metal Conduit. 120 V Integral Ballast. Medium Base Socket for Medium Base Lamps.

Description

Catalog Number

Lighting

Globes – 35 W-150 W

Lighting: Enclosed and Gasketed — Area — HID

VPGL-1HR

Clear Heat-Resistant Prismatic Glass

VPGL-1HR

Polycarbonate (100W lamp max.) ➋

VPGL-2PL

VPGL-2PL

Description

Light Distribution

IES/NEMA
Distribution Curves

Catalog Number

Refractors – 35 W-150 W
NEMA Type II

LPJR-2CG

NEMA Type V

LPJR-5CG

Closed Prismatic Glass 8” Refractors

Catalog Number
Porcelain
Polyester

Description
Reflectors – 35 W-150 W ➊

Standard

Standard (porcelain, 16” dia.; polyester, 16-1/4” dia.)

LPR-25ST

LPRP-25ST

30° Angle (porcelain, 12” dia.; polyester, 14-3/8” dia.)

LPR-25AN

LPRP-25AN

30° Angle
Description

Catalog Number

Guards – 35 W-150 W

VPGU-1

Copperfree Aluminum Guard

VPGU-1

Steel Guard for 8” Refractors

LPBG-8

35 W-150 W (Medium Base)

JRS-100

Globe Gasket, Silicone Rubber – 35W-150W

VPGL-GK

LPBG-8

Socket

Gasket

➊ V-51 reflectors cannot be used with Mercmaster Jr. Fixtures.
➋ Do not use Polycarbonate Globes in ambients exceeding 77 °F/25 °C. These globes for burning in vertical base-up position only.

1026

Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

Mercmaster™ Jr. Luminaire Dimensions
35 W, 50 W, 70 W, 100 W, 150 W

UNILETS® for Use with Threaded Metal Conduit. 120 V Integral Ballast. Medium Base Socket for Medium Base Lamps.

Lighting

Fixture with 8” Refractor

Lighting: Enclosed and Gasketed — Area — HID

MBL Ballast Body

Fixture with Guard and Polyester Reflectors

VXHA Ceiling Mount

VMA Pendant Mount

GSW Wall Mount ➊ and GS Ceiling Mount with GSU Box ➋

➌

Stanchion Mount ❻ ➍

OBV Outlet Box Mount and Mounting Plate

JBW Wall Mount ➊ with JBX Box ➋

➊ Mounting holes 9/32” diameter on 5-1/8” centers. Mounting plate is a separate piece furnished with outlet box mount fixture. The 2.75” dimension is for
mounting on 3-1/4” octagonal boxes and the 3.50” dimension is for 4” octagonal boxes.
➋ Wall mount fixtures provide the following wall clearances: with GSU box – 2” from wall with globe and 1-5/16” from wall with refractor; with JBX box – 1-5/8”
from wall with globe and 15/16” from wall with refractor. Reflectors cannot be used with wall mount fixtures.
➌ Order GSU or JBX box separately.
➍ Standard dome or 30° angle reflectors can be used with stanchion mount.
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

1027

Mercmaster™ LED Luminaires

cETLus Certification. Enclosed and Gasketed
Class I, Division 2, Groups A, B, C, D
Class I, Zone 2
Type 3R, 4X
IP66, IP67
Suitable for Use in Wet Locations
Marine Outside Type (Salt Water)

Lighting: Enclosed and Gasketed — Area — LED/Induction

Lighting

Applications
•	 Enclosed and gasketed fixtures suitable for use in:
— Marine and wet locations
— A wide range of industrial, chemical processing and other
areas where flammable gases and vapors are present under
conditions defined by the National Electrical Code as Class I, 	
Division 2
—	Areas of low clearance, low ceiling heights or where fixture
weights must be minimized
— Non-hazardous locations where severe weather conditions,
excessive moisture, dirt, dust, corrosive atmosphere or high
ambient temperatures are encountered
•	 Typical applications include:
— Pulp and paper mills
— Processing plants
— Chemical plants
— Oil refineries
— Foundries
— Manufacturing plants
— Storage areas
— Waste and sewage treatment
— Parking garages
— Other areas where dust, water, dirt and rough usage are a
problem

Features
•	 Compact light-weight low profile design is suited for low
mounting heights.
•	 Modular design allows scores of fixture component
combinations to meet installation needs. Uses same mounting
hoods as Mercmaster III.
•	 Fixture housing and mounting hoods are copperfree cast
aluminum with baked epoxy finish. All exposed hardware is
stainless steel.
•	 Accommodates a wide range of voltages.
•	 Ambient:  -40 ˚F to 131 ˚F / -40 ˚C to 55 ˚C
•	 Electrical: 120-277 Vac, 50/60 Hz; 347-480 Vac, 50/60 Hz
•	 Hinge has high lip for added safety during installation
and servicing. Hinge and bolt construction assures 360º
compression at all points on ballast housing gasket for positive
sealing. Swing away design of captive bolt and nut simplifies
servicing.
•	 All Mercmaster mounting hoods have provision for easy field
installation of fuses in fixtures (see Fixture Unit — Electrical
Specification).

Certifications and Compliances
•	 UL Standard: UL 1598, UL 1598A, UL 8750, UL 844
•	 CSA Standard: C22.2 No. 250, C22.2 No. 137
•	 cETLus Listed

Related Products
•	 Photocells for classified use are available, see PCD2 Series.

Standard Materials
•	 Mounting hoods and bodies: cast copperfree (4/10 of 1% max.)
aluminum
•	 All hardware and catch assemblies: stainless steel
•	 Globes: polycarbonate

Standard Finishes
•	 Mounting hoods, bodies and guards: baked gray epoxy-clad
finish, electrostatically applied for complete uniform protection

1028

Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

Mercmaster™ LED Luminaires

cETLus Certification. Enclosed and Gasketed
Class I, Division 2, Groups A, B, C, D
Class I, Zone 2
Type 3R, 4X
IP66, IP67
Suitable for Use in Wet Locations
Marine Outside Type (Salt Water)

Illustrated Features

Driver Assembly
Utilizing non-sparking components
avoiding the ignition of gases or vapors
that may be present (nA).

LED Chamber
Protected by polycarbonate lens, allows
for easy maintenance access.

Lighting

Heatsink
Reliable heat transfer via the cast, epoxy
powder coat aluminum body. Provides
maximum heat dissipation from the LED
assembly to the outside environment.

Modular Plug between LED and driver.

Fuses
Two screws secure fuse kit to mounting
boss in any Mercmaster mounting hood.
Fuse included.
Photocell
Available for all fixtures except cone and
ceiling mount. Installs through knock-out
in mounting hood. Provides continuous
ON-OFF dusk-to-dawn control.

Epoxy Finish
Ballast housing, hoods and guards are
copperfree aluminum with epoxy powder
coat finish.
Electrical Protection
Ground wire provided to bond mounting
hood to ballast housing.
Safety
Rounded heatsink edges prevent possible
injury during installation.

Cooler Operating Cone Hood
Larger sloped surface sheds dusts, dirt
and combustible fibers providing better
heat dissipation.
Mounting Hood and Globe Gaskets
Silicone rubber gaskets seals out
moisture, dirt and dust. Stays flexible,
withstands high temperatures. Closure
design assures uniform gasket
compression.

"Safety" High Hinge
Extra-high hinge provides additional
protection against accidental ballast
housing disengagement during installation
or maintenance.
Stainless Steel Latch Assembly
Captive, stainless steel latch assembly
bolt and nut closes securely, resists attack
of corrosive atmospheres. Swing-away
design simplifies servicing.

Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

1029

Lighting: Enclosed and Gasketed — Area — LED/Induction

Terminal Blocks (Zone 2)
A seven-point terminal block is provided
to facilitate wiring. Terminal block
accommodates wire size ranging from #8
to #24 AWG.

Mercmaster™ LED Luminaires

cETLus Certification. Enclosed and Gasketed
Class I, Division 2, Groups A, B, C, D
Class I, Zone 2
Type 3R, 4X
IP66, IP67
Suitable for Use in Wet Locations
Marine Outside Type (Salt Water)

Order using catalog numbering guide below or select catalog number from tables on following pages.
Catalog Numbering Guide
MLED

A

17

Series:
MLED - 	
Mercmaster
LED

Light Level:
17 - 175 W

Mounting:
A - Pendant
C - Ceiling
D - Pendant Cone
R - 90º Stanchion
S - 25º Stanchion
W - Wall

Lighting

Lighting: Enclosed and Gasketed — Area — LED/Induction

2

P

5

BU

Optical Assembly:
P - Polycarbonate
Globe

Hub Size:
2 - 3/4” NPT
3 - 1” NPT
4 - 1-1/4” NPT
stanchion
5 - 1-1/2” NPT
stanchion

H1

Voltage:
BU - Universal
Voltages 	
120-277 Vac,
50/60 Hz
BH - 347-480 Vac,
50/60 Hz

Light Distribution:
5 - NEMA 5

Options:
F - Fusing ➊
H1 - Photocontrol 120 V
H2 - Photocontrol 208 V
H3 - Photocontrol 240 V
H4 - Photocontrol 277 V

Technical Data
Lamp
Light Level Equivalent

Type

175 Watt PSMH

Supply Wire
Temperature (°F/°C)

Ambient
Temperature (°F/°C)

Class I, Division 2

149/65

104/40

T4A

167/75

131/55

T4

LED

“T” Numbers Represent the Maximum Lamp Temperature for Class I, Division 2 Locations and
Maximum Surface Temperature Under Dust Blanket for Class II, Division 1 Locations.
“T” #

T1

350

325

T2

T2A

T2B

T2C

T2D

T3

T3A

T3B

T3C

T4

T4A

T5

T6

Temp.
Range (˚ºF)

664842

619662

574617

538572

502536

448500

421446

394419

358392

331356

322329

277320

250275

214248

187212

185

Temp.
Range (°C)

351450

326350

301325

281300

261280

231260

216230

201215

181200

166180

161165

136160

121135

101120

86100

85

➊ Canadian Electrical Code does NOT allow fusing in hazardous locations V.
V CSA Certification Only.

1030

Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

Mercmaster™ LED Luminaires

cETLus Certification. Enclosed and Gasketed
Class I, Division 2, Groups A, B, C, D
Class I, Zone 2
Type 3R, 4X
IP66, IP67
Suitable for Use in Wet Locations
Marine Outside Type (Salt Water)

Lamp Type

Light Level

LED

17

Hub Size
(Inches)

Catalog Numbers ➊

3/4

MLEDA172P5

1

MLEDA173P5

3/4

MLEDD172P5

1

MLEDD173P5

3/4

MLEDC172P5

1

MLEDC173P5

Pendant ­— One Hub, Rigid Mounting

Pendant Cone ­— One Hub, Rigid Mounting

17

LED



Suffix
BU
BH

Voltage AC
120 - 277
347 - 480

17

Frequency
50/60 Hz
50/60 Hz

Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

1031

Lighting: Enclosed and Gasketed — Area — LED/Induction

Ceiling —
­ Five Hubs, Four Close-up Plugs

Lighting

LED

Mercmaster™ LED Luminaires

cETLus Certification. Enclosed and Gasketed
Class I, Division 2, Groups A, B, C, D
Class I, Zone 2
Type 3R, 4X
IP66, IP67
Suitable for Use in Wet Locations
Marine Outside Type (Salt Water)

Lamp Type

Light Level

LED

17

Hub Size
(Inches)

Catalog Numbers ➊

3/4

MLEDW172P5

1

MLEDW173P5

1-1/4

MLEDS174P5

1-1/2

MLEDS175P5

1-1/4

MLEDR174P5

1-1/2

MLEDR175P5

Wall —
­ Five Hubs, Four Close-Up Plugs

Lighting: Enclosed and Gasketed — Area — LED/Induction

Lighting

25° Stanchion —
­ One Hub

LED

17

90° Stanchion —
­ One Hub

LED



Suffix
BU
BH

1032

Voltage AC
120 - 277
347 - 480

17

Frequency
50/60 Hz
50/60 Hz
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

Mercmaster™ LED Luminaire Mounting Hoods and Ballast Bodies
cETLus Certification. Enclosed and Gasketed
Class I, Division 2, Groups A, B, C, D
Class I, Zone 2
Type 3R, 4X
IP66, IP67
Suitable for Use in Wet Locations
Marine Outside Type (Salt Water)

Mounting Hoods
Description

Hub Size (Inches)

Catalog Number

Pendant
One Hub, Rigid Mounting

3/4

KPA-75

1

KPA-100

3/4

KPCH-75

1

KPCH-100

Pendant Cone
One Hub, Rigid Mounting
Ceiling
Lighting

Five Hubs, Four Close-Up Plugs

3/4

KPC-75

1

KPC-100

3/4

KPWB-75

1

KPWB-100

Wall
Five Hubs, Four Close-Up Plugs

One Hub

1-1/4

KPS-125

1-1/2

KPS-150

1-1/4

KPST-125

1-1/2

KPST-150

90° Stanchion
One Hub

Replacement Globe Gaskets – Silicone Rubber
Description

Catalog Number
KRF-GK

Refractor Gasket

Fixture Unit — Electrical Specification
Catalog Number
Current Draw

Fuse Kit ➊

Fixture Unit

Voltage Range

Voltage
Suffix

120 Vac @ .77 Amps
277 Vac @ .35 Amps

F3

MLED17P5

120-277 Vac, 50/60 Hz

BU

347 Vac @ .32 Amps
480 Vac @ .23 Amps

F3

MLED17P5

347-480 Vac, 50/60 Hz

BH

➊ Canadian Electrical Code does NOT allow fusing in hazardous locations V.
V CSA Certification Only.
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

1033

Lighting: Enclosed and Gasketed — Area — LED/Induction

25° Stanchion

PCD2 Series Factory Sealed Hazardous Location Photocontrol
For Use in Class I, Division 2, Groups A, B, C, D Locations

Maintains Class I, Division 2 rating for Mercmaster III – Low Profile, Mercmaster III, and Mercmaster III – 400 Series Luminaires, Mercmaster LED.
Class I, Division 2, Groups A, B, C, D
NEMA 4X

Applications

Materials

•	 Encapsulated photocontrol provides automatic dusk-to-dawn
lighting control in Class I, Division 2 locations.
•	 Typical applications include walkways, security areas and any
other outdoor lighting application.
•	 For use with Mercmaster III – Low Profile, Mercmaster III, and
Mercmaster III – 400 Series Luminaires.
•	 For remote mounting in FS Boxes.

•	 Encapsulated with epoxy sealing compound
•	 FS: aluminum

Certifications and Compliances
•	 UL Standard: 1604 ­– Hazardous (Classified) Locations
•	 cULus Recognized

Lighting: Enclosed and Gasketed — Area — LED/Induction

Lighting

Features
•	 Factory sealed design eliminates the need for an explosionproof
enclosure.
•	 Can be easily installed in the field.
•	 Solid state design for performance and reliability.
•	 Available for 120, 208, 240, or 277 volts.
•	 50-400 W HID, incandescent or fluorescent, 50/60 Hz.
•	 1000 VA Voltage/Ampere
•	 Minimum time delay: 15 seconds to eliminate nuisance tripping.
•	 Provided with (3) 18AWG stranded  leads 6”/152.4 mm in
length.
•	 Will fit through standard 1/2” knockout.

Factory-Installed Photocontrol

Dimensions

Add to fixture catalog after voltage; i.e.: KPWBL1075MTH1.

Mercmaster III wall mounting hood
with photocontrol installed shown

Voltage Range

Suffix Designation

120 V, 50/60 Hz

H1

208 V, 50/60 Hz

H2

240 V, 50/60 Hz

H3

277 V, 50/60 Hz

H4
1.13”
28.7
mm
1.13”
28.7 mm

Photocontrol in FS Cover for Use with FS/FD Box

Supplied with two stainless steel screws. For neoprene gasket, order catalog number FS-GKR-1N.

Voltage Range

Catalog Number

120V, 50/60 Hz

FSKA-PC120D2

208-277V, 50/60 Hz

FSKA-PC247D2

1.375”
34.9
mm
1.375”
34.9 mm
2.56”
65.0
mm
2.56”
65.0 mm

1.13”
28.7 mm

Photocontrol for Field Installation
Max. Current

Catalog Number

120 V, 50/60 Hz

Voltage Range

8.3 Amp

PC120D2

208-277 V, 50/60 Hz

3.5 Amp

34.9 mm
PC247D2

2.56”
65.0 mm

1034

1.375”

0.69”
17.5 mm
1.19”
30.2 mm

1.94”
49.2 mm

Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

Mercmaster™ LED Luminaire Dimensions
16.93”/
430.0 mm

15.27”/
387.9 mm

cETLus Certification. Enclosed and Gasketed

18.63”/473.2 mm

9.25”/
235.0 mm

77.6 mm

5.59”/
142.0 mm

11.96”/
303.8 mm
25°

15.40”/
391.16 mm
Dia.

Dimensions in Inches/Millimeters

15.40”/391.16 mm Dia.
WALL MOUNT

18.63”/473.2 mm

9.25”/
15.27”/
235.0 mm
387.9 mm
9.79”/248.7 mm
Depends on
Length of
9.25”/
Conduit Used
235.0 mm

18.63”/473.2 mm
10.93”/277.6 mm

17.22”/437.4 mm
5.59”/
142.0 mm
5.59”/
142.0 mm

11.96”/
303.8 mm

4.06”/
8.43”/
103.1
mm mm
214.1

9.40”/
238.8 mm

PENDANT CONE MOUNT

15.27”/
387.9 mm
16.93”/
mm
430.0 18.87”/479.3
mm

10.93”/277.6 mm

4.06”/
103.1 mm

15.40”/391.16 mm Dia.

16.93”/
430.0 mm

ANGLE STANCHION MOUNT

7.56”/
192.0 mm25°

9.40”/
238.8 mm

25°

15.40”/
391.16 mm
15.40”/391.16
mm Dia.
Dia.

15.40”/391.16
mmmm
Dia.Dia.
15.40”/391.16

15.40”/391.16 mm Dia.
CEILING MOUNT

PENDANT MOUNT
WALL MOUNT
15.40”/391.16 mm Dia.

11.96”/
303.8 mm

15.40”/
391.16 mm
Dia.

15.40”/391.16 mm Dia.

STANCHION MOUNT
ANGLE STANCHION MOUNT

PENDANT CONE MOUNT
15.40”/391.16 mm Dia.
Pendant Cone Mount
18.87”/479.3 mm

ANGLE STANCHION MOUNT

WALL MOUNT

PENDANT CONE MOUNT
17.22”/437.4 mm

9.40”/
238.8 mm

PENDANT MOUNT

15.40”/391.16 mm Dia.

15.40”/391.16 mm Dia.

CEILING MOUNT

PENDANT MOUNT

Ceiling Mount

9.40”/
238.8 mm

Wall Mount

WALL MOUNT

15.40”/
391.16 mm
Dia.

15.40”/391.16 mm Dia.
ANGLE STANCHION MOUNT

WALL MOUNT

PENDANT CONE MOUNT

16.93”/
430.0 mm

8.43”/
214.1 mm

18.87”/479.3 mm

15.27”/
387.9 mm
18.63”/473.2 mm

25°

STANCHION MOUNT
15.40”/391.16 mm Dia.
STANCHION MOUNT
15.40”/391.16 mm Dia.

11.96”/
303.8 mm
25°

15.40”/391.16 mm Dia.

5.59”/
142.0 mm

15.40”/391.16 mm Dia.

17.22”/437.4 mm
Depends on
Length of
Conduit Used

9.25”/
235.0 mm

10.93”/277.6 mm

9.25”/
235.0 mm

5.59”/
142.0 mm

9.79”/248.7 mm

15.40”/391.16 mm Dia.
CEILING MOUNT

8.43”/
214.1 mm

7.56”/
192.0 mm

11.96”/
303.8 mm
25°
15.40”/391.16 mm Dia.

15.40”/
391.16 mm
Dia.

15.40”/391.16 mm Dia.

15.40”/391.16 mm Dia.

CEILING MOUNT

STANCHION MOUNT

PENDANT MOUNT
15.40”/391.16 mm Dia.

15.40”/391.16 mm Dia.
STANCHION MOUNT
25° ANGLE
Stanchion
Mount

WALL MOUNT

PENDANT CONE MOUNT

90° Stanchion Mount

18.87”/479.3 mm
17.22”/437.4 mm
Depends on
Length of
Conduit Used

8.43”/
214.1 mm

7.56”/
192.0 mm

Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
15.40”/391.16 mm Dia.

15.40”/391.16 mm Dia.
CEILING MOUNT

9.79”/248.7 mm

PENDANT MOUNT

1035
15.40”/391.16 mm Dia.
STANCHION MOUNT

Lighting: Enclosed and Gasketed — Area — LED/Induction

4.06”/
103.1 mm

18.63”/473.2 mm

4.06”/
103.1 mm
7.56”/
192.0 mm

15.40”/391.16 mm Dia.

9.25”/
235.0 mm

CEILING MOUNT

9.79”/248.7 mm
10.93”/277.6 mm

7.56”/
192.0 mm

16.93”/
8.43”/
430.0 mm
214.1 mm
15.27”/
387.9 mm
15.40”/391.16 mm Dia.
18.63”/473.2 mm

15.27”/
387.9 mm

17.22”/437.4 mm

Depends on
Length of
Conduit Used

8.43”/
214.1 mm

16.93”/
430.0 mm

9.79”/248.7 18.87”/479.3
mm
mm

Depends on
Length of
Conduit Used

10.93”/277.6 mm

Lighting

Pendant Mount

ANGLE

15.40”/3

PEND

Mercmaster™ LED Luminaire Weights and Photometric Data
cETLus Certification. Enclosed and Gasketed

Lighting: Enclosed and Gasketed — Area — LED/Induction

Lighting

Mercmaster LED Ballast and Accessory Weights
Description

Weight in Lbs/Kg

Fixture Unit
Pendant
Pendant Cone

22.00/10.0
2.25/1.0
2.50/1.1

Ceiling

3.00/1.4

Wall

4.00/1.8

25° Stanchion

3.25/1.5

90° Stanchion

3.75/1.7

Photometric Data
5 Degree Lumens
0-5

68

5-10

201

10-15

326

CIE Type – Direct

REPORT NUMBER: MLED17P
Lamps: MercMaster LED, Class 1, Div 2, Polycarbonate Optic
Coefficients of Utilization – Zonal Cavity Method

15-20

445

20-25

546

25-30

624

% CeilingRcc

30-35

652

% Walls Rw 70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10

Effective Floor Cavity Reflectance 0.20
80

70

50

30

10

0
0

35-40

646

0 119 119 119 119 116 116 116 116 111 111 111 106 106 106 102 102 102 100

40-45

610

1 111 108 104 102 109 106 103 100 101 99 97 98 96 94 94 93 91 89

45-50

556

2 103 97 91 87 101 95 90 86 91 87 84 88 85 82 85 83 80 78

50-55

473

3 96 87 80 75 93 85 79 74 83 77 73 80 75 72 77 74 70 69

55-60

355

4 88 78 71 65 86 77 70 65 75 69 64 72 67 63 70 66 62 60

60-65

213

65-70

96

70-75

25

75-80

7

Zonal Lumen Summary
Zone
0-30

Lumens

% Fixture

2212

37.8

5 82 71 63 57 80 70 62 57 68 61 56 66 60 56 64 59 55

53

6 76 64 56 51 74 64 56 51 62 55 50 60 54 50 59 53 49

48

7 71 59 51 45 69 58 51 45 57 50 45 55 49 45 54 49 44 43
8 66 54 46 41 65 53 46 41 52 45 41 51 45 40 50 44 40 38

80-85

5

0-40

3509

59.9

9 62 50 42 37 61 49 42 37 48 42

37 47 41 37 46 41 37 35

85-90

3

0-60

5503

94.0

10 58 46 39 34 57 46 39 34 45 38

34 44 38 34 43 37 33 32

5851

99.9

90-95

1

0-90

95-100

1

90-120

3

0.1

100-105

0

90-130

5

0.1

105-110

0

90-150

5

0.1

110-115

1

90-180

5

0.1

0-180

5856

100.0

115-120

1

120-125

1

125-130

1

130-135

0

135-140

0

140-145

0

145-150

0

150-155

0

155-160

0

160-165

0

165-170

0

170-175

0

175-180

0

1036

Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

Mercmaster™ III Induction Luminaires

Enclosed and Gasketed. For Hazardous and Adverse Locations
55W, 85W, 165W
Class I, Division 2, Groups A, B, C, D
Class II, Division 1 and 2, Groups E, F, G
NEMA 4X

55W, 85W
Class I, Zone 2
AEx nA nR, IIC
Ex nA nR IIC

165W
Class I, Zone 2
AEx nR, IIC
Ex nR IIC

Applications

Lighting

•	 Areas where access for relamping is difficult, reliability is 	
essential and the environment is costly to maintain.
•	 Cold environment applications.
•	 Enclosed and gasketed fixtures suitable for use in marine
and wet locations, and in a wide range of industrial, chemical
processing and other areas where flammable gases and vapors
or combustible dusts are present under conditions defined by
NEC Class I, Division 2.
•	 Fixtures are also well suited for use in non-hazardous areas 	
where severe weather conditions, excessive moisture, dirt,	
dust and corrosive atmospheres are a problem.
•	 Typical applications include pulp and paper mills, processing
plants, chemical plants, oil refineries, foundries, manufacturing
plants, storage areas and marine applications. Fixtures have
NEMA 4X listing.

Features
•	
•	
•	
•	

•	
•	
•	
•	
•	

•	

•	

•	

•	

•	
•	
•	

Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

165 Watt Ceiling Mount Fixture with
Prismatic Glass Globe

Standard Materials
•	 Mounting hoods, ballast bodies and guards: cast copperfree
(4/10 of 1% max.) aluminum
•	 Exposed hardware: stainless steel; latch assemblies have
stainless steel bolt and captive nut; reflectors and guards attach
with stainless steel screws threading into stainless steel inserts
•	 Reflectors: fiberglass reinforced white polyester
•	 Globes: heat-resistant prismatic glass

Standard Finishes
•	 Mounting hoods, ballast bodies, guards: epoxy powder
coat finish, electrostatically applied for complete, uniform
surface protection
•	 Reflectors: white polyester finish

Options
•	 Fuses can be field-installed on Mercmaster III fixtures. Kits
include fuse block, wire connectors and screws for attaching	
to mounting hood. Fixtures with fuses do not comply with
Marine Type Electric Fixtures Outside Type (Salt Water)
requirements for marine listing.
•	 Photocell optional for all fixtures except cone and ceiling
mounts; provides automatic “on-off” control.

Certifications and Compliances
•	 UL Standard: UL 1598, UL 844, UL 1598A
•	 CSA Standard: C22.2 No. 250, C22.2 No. 137
•	 cCSAus Certified

1037

Lighting: Enclosed and Gasketed — Area — LED/Induction

•	
•	

Instant start and restrike.
High lumen output and efficacy (up to 73 lumens per Watt).
Fixtures operate safely in a 104 °F/40 °C ambient.
Good lumen maintenance provides less than 30% depreciation
after 60K hours of operation.
Virtually maintenance free.
Ultra long 100,000 hours of life keeps maintenance costs to 	
a minimum.
Starts in temperatures as low as -40 °F/-40 °C.
Low total harmonic distortion (less than 10%).
No cycling at end of life.
Modular design allows scores of fixture component
combinations to meet installation and lighting needs.
Mounting hoods include cone-shaped pendant, standard
pendant, flexible pendant, ceiling and wall (tapped for 3/4” or 1”
NPT), 25° angle stanchion and straight stanchion (both tapped
for 1-1/4” or 1-1/2” NPT).
Cone hood fixtures for pendant mounting shed dust, dirt and
combustible fibers, and inhibit build-up that “insulates” fixture
and slows heat transfer. Also provide increased surface area for
more effective heat dissipation.
Reflector choice includes standard dome and 30º angle types,
both made of fiberglass reinforced white polyester. Highly
resistant to unusually corrosive applications. Reflectors are
vented for cooler, dirt-free operation and maintained lumen
output. They secure to ballast housing with stainless steel
screws threading into stainless steel inserts.
For high corrosion resistance, fixture housing, mounting hoods
and guards are copperfree (4/10 of 1% max.) cast aluminum
with baked epoxy finish, electrostatically applied for uniformity.
All exposed hardware is stainless steel.
Hinge has high lip for added safety during installation
and servicing. Hinge and bolt construction assures 360º
compression at all points on ballast housing gasket for 	
positive sealing. Swing-away design of captive bolt and 	
nut simplifies servicing.
Body gaskets and globe gaskets are high-temperature 	
silicone rubber.
All Mercmaster III mounting hoods have provision for easy 	
field installation of fuses in fixtures (see fuse kit listings in this
catalog section).
For electrical protection, a ground wire is provided on each
Mercmaster to bond hood and ballast housing.

Mercmaster™ III Induction Luminaires

Enclosed and Gasketed. For Hazardous and Adverse Locations
55W, 85W, 165W
Class I, Division 2, Groups A, B, C, D
Class II, Division 1 and 2, Groups E, F, G
NEMA 4X

55W, 85W
Class I, Zone 2
AEx nA nR, IIC
Ex nA nR IIC

165W
Class I, Zone 2
AEx nR, IIC
Ex nR IIC

Lighting

Illustrated Features

Aluminum Inner Reflector
Solid aluminum inner reflector improves
photometric efficiency.

Lighting: Enclosed and Gasketed — Area — LED/Induction

Epoxy Finish
Ballast housing, hoods and guards are
copperfree aluminum with epoxy powder
coat finish.

Rugged, Vented Reflectors
Reflectors are thick, tough fiberglass
reinforced white polyester, vented for
cooler operation. Quickly attach with
stainless steel screws provided.
Threaded Stainless Steel Inserts for
Screws
Fixture bodies have stainless steel
threaded inserts to receive stainless steel
screws for reflector and guard. Prevents
“freezing”, allowing guards and reflectors
to be easily removed and replaced at any
time, without damage to the housing.
Prismatic Glass Globes, Refractors
and Enclosed Reflector
Heat-resistant globes, refractors and
enclosed reflectors thread into ballast
housing and seal against a hightemperature silicone rubber gasket.

Fuses Mount to Hood Bosses
Two screws secure fuse kit to mounting
boss in any Mercmaster mounting hood.
Electrical Protection
Ground wire provided to bond mounting
hood to ballast housing.
Stainless Steel
Latch Assembly
Captive, stainless
steel latch assembly
bolt and nut closes
securely, resists
attack of corrosive
atmospheres. 	
Swing-away design
simplifies servicing.

1038

Mounting Hood and Globe Gaskets
Silicone rubber gaskets seals out
moisture, dirt and dust. Stays flexible,
withstands high temperatures. Closure
design assures uniform gasket
compression.

Cooler Operating Cone Hood
Sloped surface sheds insulating dust,
dirt, and combustible fibers. Provides
cleaner, larger surface area for better heat
dissipation.
Photocell
Available for all fixtures except cone and
ceiling mount. Installs through knock-out
in mounting hood. Provides continuous
ON-OFF dusk-to-dawn control.
“Safety” High
Hinge
Extra-high hinge
provides additional
protection against
accidental
ballast housing
disengagement
during installation
or maintenance.

Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

Mercmaster™ III Induction Luminaires

Enclosed and Gasketed. For Hazardous and Adverse Locations
55W, 85W, 165W
Class I, Division 2, Groups A, B, C, D
Class II, Division 1 and 2, Groups E, F, G
NEMA 4X

55W, 85W
Class I, Zone 2
AEx nA nR, IIC
Ex nA nR IIC

165W
Class I, Zone 2
AEx nR, IIC
Ex nR IIC

“T” Numbers for Mercmaster III Induction Fixtures ­— Class I, Division 2 and Class II, Division 1 and 2
Class I, Division 2, Groups A, B, C, D
NEC/CEC V Temp.
Indent. Number Nameplate Marking

Class II, Division 1 and 2, Groups E, F, G
NEC/CEC V Temp.
Indent. Number Nameplate Marking

Lamp
Type

Supply
Wire
Temp.
(°F/°C)

Ambient
Temp.
(°F/°C)

Input
Voltage

55

Induction

194/90

104/40

100-120

T3A

­—

—

T6

­—

—

55

Induction

194/90

104/40

200-277

T3B

—

—

T6

—

—

85

Induction

194/90

104/40

100-120

T3A

—

—

T6

—

—

Lamp
Watts

with Globe or
with
with Enclosed
Globe and Reflector Refractor
Reflector

with Globe or
Globe and Reflector

with
with Enclosed
Refractor
Reflector

Induction

194/90

104/40

200-277

T3A

—

—

T6

—

—

Induction

194/90

104/40

100-120

T3

T3

T3

T5

T5

T5

165

Induction

194/90

104/40

200-277

T3

T3

T3

T5

T5

T5

Lighting

85
165

“T” Numbers for Mercmaster III Induction Fixtures —
­ Class I, Zone 2

Lamp
Type

Supply
Wire
Temp.
(°F/°C)

Ambient
Temp.
(°F/°C)

Input
Voltage

55

Induction

194/90

104/40

55

Induction

194/90

85

Induction

194/90

85

Induction

165
165

Lamp
Watts

Class I, Zone 2
AEx nR IIC / Ex nR IIC

with Globe

with
Globe and
Reflector

with Globe

with Globe
and Reflector

with
Refractor

Reflector
with Lens

100-120

T4

T4

—

—

­—

—

104/40

200-277

T4

T4

—

—

—

—

104/40

100-120

T4

T4

—

—

—

—

194/90

104/40

200-277

T4

T4

—

—

—

—

Induction

194/90

104/40

100-120

—

—

T5

T5

—

T5

Induction

194/90

104/40

200-277

—

—

T5

T5

—

T5

“T” Numbers Represent the Maximum Lamp Temperature for Class I, Division 2 Locations and
Maximum Surface Temperature Under Dust Blanket for Class II, Division 1 Locations.
“T”
Number

T1

350

325

T2

T2A

T2B

T2C

T2D

T3

T3A

T3B

T3C

T4

T4A

T5

T6

Temp.
Range
(˚ºF)

664842

619662

574617

538572

502536

448500

421446

394419

358392

331356

322329

277320

250275

214248

187212

185

Temp
Range
(°C)

351-	
450

326-	
350

301-	
325

281-	
300

261-	
280

231-	
260

216-	
230

201-	
215

181-	
200

166-	
180

161-	
165

136-	
160

121-	
135

101-	
86-100
120

85

V CSA Certification Only.

Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

1039

Lighting: Enclosed and Gasketed — Area — LED/Induction

Class I, Zone 2
AEx nA nR IIC / Ex nA nR IIC

Mercmaster™ III Induction Luminaires

Enclosed and Gasketed. For Hazardous and Adverse Locations
55W, 85W, 165W
Class I, Division 2, Groups A, B, C, D
Class II, Division 1 and 2, Groups E, F, G
NEMA 4X

165W
Class I, Zone 2
AEx nR, IIC
Ex nR IIC

55W, 85W ➎➏
Class I, Zone 2
AEx nA nR, IIC
Ex nA nR IIC

Type
Mounting

Lamp
Watts

Hub Size
(Inches)

Catalog Numbers ➊➋➌
with Globe

Pendant
55 ➎➏
One Hub
Rigid Mounting ➍

85 ➎➏

165

Shown with 55 Watt Globe

3/4

MLAQ552G3N

1

MLAQ553G3N

3/4

MLAQ852G4N

1

MLAQ853G4N

3/4

KPAQ1652G4N

1

KPAQ1653G4N

3/4

MLDQ552G3N

1

MLDQ553G3N

3/4

MLDQ852G4N

1

MLDQ853G4N

3/4

KPDQ1652G4N

1

KPDQ1653G4N

3/4

MLCQ552G3N

1

MLCQ553G3N

3/4

MLCQ852G4N

1

MLCQ853G4N

3/4

KPCQ1652G4N

1

KPCQ1653G4N

Lighting

Pendant Cone Hood
55 ➎➏

Lighting: Enclosed and Gasketed — Area — LED/Induction

One Hub
Rigid Mounting

85 ➎➏

165

Shown with 55 Watt Globe
Ceiling

55 ➎➏
Five Hubs
Four Close-Up Plugs

85 ➎➏

Shown with 55 Watt Refractor

165

➊ Add voltage suffix -A1 for 120 Vac: 90-140 Vac; -A6 for 277: 180-305 Vac.
➋ See following pages for accessory ordering information.
➌ For fixtures with guard, substitute G for N before adding suffix.
➍ For flexible pendant mount, change A to F in catalog number.
➎ Add Z2 suffix for factory sealed non-sparking/restricted breathing protection (AEx nA nR).
➏ Add Z suffix for factory sealed non-sparking/restricted breathing protection (Ex nA nR) V.
V CSA Certification Only.

1040

Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

Mercmaster™ III Induction Luminaires

Enclosed and Gasketed. For Hazardous and Adverse Locations
55W, 85W, 165W
Class I, Division 2, Groups A, B, C, D
Class II, Division 1 and 2, Groups E, F, G
NEMA 4X

165W
Class I, Zone 2
AEx nR, IIC
Ex nR IIC

55W, 85W ➎➏
Class I, Zone 2
AEx nA nR, IIC
Ex nA nR IIC

Type
Mounting

Lamp
Watts

Hub Size
(Inches)

Catalog Numbers ➊➋➌
with Globe

Wall
55 ➎➏
Five Hubs
Four Close-Up Plugs

85 ➎➏

165

Shown with 85 Watt Globe

3/4

MLWQ552G3N

1

MLWQ553G3N

3/4

MLWQ852G4N

1

MLWQ853G4N

3/4

KPWQ1652G4N

1

KPWQ1653G4N

55 ➎➏

One Hub

85 ➎➏

MLSQ554G3N

1-1/2

MLSQ555G3N

1-1/4

MLSQ854G4N

1-1/2

MLSQ855G4N

1-1/4

KPSQ1654G4N

1-1/2

KPSQ1655G4N

1-1/4

MLRQ554G3N

1-1/2

MLRQ555G3N

1-1/4

MLRQ854G4N

1-1/2

MLRQ855G4N

1-1/4

KPRQ1654G4N

1-1/2

KPRQ1655G4N

Lighting: Enclosed and Gasketed — Area — LED/Induction

165

Shown with 55 Watt Globe

1-1/4

Lighting

25° Stanchion

Straight Stanchion
55 ➎➏

One Hub

85 ➎➏

Shown with 55 Watt Globe

165

➊ Add voltage suffix -A1 for 120 Vac: 90-140 Vac; -A6 for 277: 180-305 Vac.
➋ See following pages for accessory ordering information.
➌ For fixtures with guard, substitute G for N before adding suffix.
➎ Add Z2 suffix for factory sealed non-sparking/restricted breathing protection (AEx nA nR).
➏ Add Z suffix for factory sealed non-sparking/restricted breathing protection (Ex nA nR). V
V CSA Certification Only.
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

1041

Mercmaster™ III Induction Luminaire Mounting Hoods
Enclosed and Gasketed. For Hazardous and Adverse Locations
55W, 85W, 165W
Class I, Division 2, Groups A, B, C, D
Class II, Division 1 and 2, Groups E, F, G
NEMA 4X

55W, 85W
Class I, Zone 2
AEx nA nR, IIC
Ex nA nR IIC

Description

165W
Class I, Zone 2
AEx nR, IIC
Ex nR IIC

Hub Size
(Inches)

Catalog Number

Pendant
One Hub,
Rigid Mounting

3/4

KPA-75

1

KPA-100

One Hub,
Flexible Mounting

3/4

KPAF-75

1

KPAF-100

Cone Hood
Rigid Mounting

3/4

KPCH-75

1

KPCH-100

Five Hubs,
Four Close-Up Plugs

3/4

KPC-75

1

KPC-100

Five Hubs,
Four Close-Up Plugs

3/4

KPWB-75

1

KPWB-100

Lighting: Enclosed and Gasketed — Area — LED/Induction

Lighting

Pendant — Flexible

Pendant Cone

Ceiling

Wall

25° Stanchion
One Hub

1-1/4

KPS-125

1-1/2

KPS-150

1-1/4

KPST-125

1-1/2

KPST-150

90° Stanchion
One Hub

1042

Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

Mercmaster™ III Induction Luminaire Fixture Units

Enclosed and Gasketed. For Hazardous and Adverse Locations
55W, 85W, 165W
Class I, Division 2, Groups A, B, C, D
Class II, Division 1 and 2, Groups E, F, G
NEMA 4X

55W, 85W
Class I, Zone 2
AEx nA nR, IIC
Ex nA nR IIC

165W
Class I, Zone 2
AEx nR, IIC
Ex nR IIC

Fixture Units — Less Mounting Hoods
Type

Fixture Unit
Catalog Number

Add Voltage Suffixes
120 V
277 V

Frequency

Lamp Watts

Induction

50/60 Hz

55

MLBRG355Q

-A1

-A6

Induction

50/60 Hz

85

MLBRG485Q

-A1

-A6

Induction

50/60 Hz

165

KPB165QG4

-A1

-A6

Induction

50/60 Hz

165

KPB165QRL

-A1

-A6

Induction

50/60 Hz

165

KPB165QJ2

-A1

-A6

Induction

50/60 Hz

165

KPB165QJ5

-A1

-A6

Globe

Globe

Lighting

Globe

Lighting: Enclosed and Gasketed — Area — LED/Induction

Enclosed Reflector/Lens

Type 2 Refractor

Type 5 Refractor

Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

1043

Mercmaster™ III Induction Luminaire Accessories and Replacement Parts
Enclosed and Gasketed. For Hazardous and Adverse Locations
55W, 85W, 165W
Class I, Division 2, Groups A, B, C, D
Class II, Division 1 and 2, Groups E, F, G
NEMA 4X

55W, 85W
Class I, Zone 2
AEx nA nR, IIC
Ex nA nR IIC

Item

165W
Class I, Zone 2
AEx nR, IIC
Ex nR IIC

Description

Watts

Catalog Number

Standard Dome

55 W, 85 W, 165 W

CMR-4ST ➊

Deep Dome (Dark Skies Compliant)

55 W, 85 W, 165 W

CMR-4DD ➊

30º Angle

55 W, 85 W, 165 W

CMR-4AN ➊

White Polyester Reflectors

Lighting

Prismatic Glass Globes – Heat-Resistant
Clear

55 W

VPGL-3HR

Clear

85 W, 165 W

VPGL-4HR

Closed Glass Refractor NEMA Type II 	
Heat- and impact-resistant glass lens.

165 W

KPRF4002

Closed Glass Refractor NEMA Type V

165 W

KPRF4005

Enclosed Reflector/Lens

165 W

KPR-4HB

55 W

KRG2

Lighting: Enclosed and Gasketed — Area — LED/Induction

Refractor/Reflector Assemblies

Guards

85 W, 165 W

KPGU400

Mercmaster III Fixture Unit, Component and Accessory Weights ➋
Fixture Unit and Mounting Hoods
55W and 85W Fixture
165W Fixture
Pendant
Pendant Cone
Ceiling
Wall
25º Stanchion
90º Stanchion

Wt. lbs/kg
28.00/12.7
33.00/15.0
2.25/1.0
2.50/1.1
3.00/1.4
4.00/1.8
3.25/1.5
3.33/1.5

Reflectors
Standard Dome
30º Angle
Deep Dome

Wt. lbs/kg
2.50/1.1
2.50/1.1
3.50/1.6

Refractors, Globes & Guard
Glass Globe
Globe Guard

Wt. lbs/kg
3.75/1.7
1.00/0.5

➊ Standard and deep dome reflectors may interfere with bottom conduit entry if used with KPST and KPWB mounting hoods.
➋ Weights are approximate.

1044

Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

Mercmaster™ III Induction Luminaire Technical Data
Enclosed and Gasketed. For Hazardous and Adverse Locations
55W, 85W, 165W
Class I, Division 2, Groups A, B, C, D
Class II, Division 1 and 2, Groups E, F, G
NEMA 4X

55W, 85W
Class I, Zone 2
AEx nA nR, IIC
Ex nA nR IIC

165W
Class I, Zone 2
AEx nR, IIC
Ex nR IIC

Fuse Kit includes fuse, fuse holder and necessary hardware for field installation. Mounts easily to hood with one screw. ➊
Lamp Watts
55, 85, 165

Volts
120/277
208-240

Fuse Qty. Req.
1
2

Fuse Catalog Number
F2
F2

Electromagnetic Compatibility
A.) Complies with European norms EN55015, EN6100-3-2 and EN61547
B.) RFI
     a.) Meets standard EN55022 and is valid for frequencies up to 1000 MHz.
Electrical Characteristics

MHz
MHz
MHz
kV
mA

85 W
100-120 V
85
82
88
120
90
140
120
90
180
60
47
63
730
16
170
>0.92
2.65
2.3
3
1.5
<0.5
200Vac

85 W
200-277 V
85
82
88
230
180
305
230
180
350
50
47
63
400
12
170
>0.92
2.65
2.3
3
1.5
<0.5
400Vac

165 W
100-120 V
165
160
190
120
90
140
120
90
180
60
47
63
1420
28
150
>0.92
2.65
2.3
3.0
1.5
<0.5
200Vac

165 W
200-277 V
165
160
190
230
180
305
230
180
350
50
47
63
740
24
140
>0.92
2.65
2.3
3.0
1.5
<0.5
400Vac

Lamp Characteristics
Values at 100 Hrs.
Luminous flux nom.
Luminous flux min.
Luminous flux max.
System efficacy nom.

lm
lm
lm
lm/W

QL 55 W
3,500
3,200
3,800
63.5

QL 85 W
6,000
5,500
6,500
70

QL 165 W
12,000
11,000
12,500
72.5

Lamp Operation
A.) Ignition and Lifetime Performance
    a.) Ignition time <0.5 seconds
     Hot Restrike time <0.5 seconds
    b.) Induction lighting offers a direct, flicker-free ignition after switch-on, in both cold and hot conditions
B.) Lumen Maintenance
    a.)The lumens of an induction lamp are expected to have depreciated after 60,000 hours to no less than 75% of the initial lumens
➊ Canadian Electrical Code does NOT allow fusing in hazardous locations V.
➋ At design voltage.
V CSA Certification Only.
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

1045

Lighting: Enclosed and Gasketed — Area — LED/Induction

W
W
W
V
V
V
V
V
V
Hz
Hz
Hz
mA
A
usec

55 W
200-277 V
55
53.1
56.9
230
180
305
230
180
350
50
47
63
260
12
170
>0.92
2.65
2.3
3
1.5
<0.5
400Vac

Lighting

System power ➋ nom.
System power ➋ min.
System power ➋ max.
AC supply voltage nom.
AC supply voltage min.
AC supply voltage max.
DC supply voltage nom.
DC supply voltage min.
DC supply voltage max.
Supply frequency nom.
Supply frequency min.
Supply frequency max.
Supply current nom.
Inrush current max.
Duration inrush current max.
Power factor nom.
HF output frequency nom.
HF output frequency min.
HF output frequency max.
HF output voltage max.
Leakage current
Overvoltage

55 W
100-120 V
55
53.1
56.9
120
90
140
120
90
180
60
47
63
460
16
170
>0.92
2.65
2.3
3
1.5
<0.5
200Vac

Mercmaster™ III Induction Luminaire Dimensions

Enclosed and Gasketed. For Hazardous and Adverse Locations

13.44"/
341.4 mm

11.82"/
300.2 mm

10.38"/
263.7 mm

10.25"/
260.4 mm
10.77"/
273.6 mm

Lighting

11.44"/
290.6 mm

12.25"/
311.2 mm Dia.
14.25"/
362.0 mm Dia.

1046

10.52”/
267.2 mm
11.32"/
287.5 mm

15.72"/
399.3 mm

15.17"/
385.3 mm

14.81"/
376.2 mm

10.52"/
267.2 mm

85 Watt

12.37"/
314.2 mm
14.81"/
376.2 mm

4.24”/
107.7 mm

165 Watt Ceiling Mount
with Refractor, Enclosed Reflector and Guards

4.24"/
107.7 mm

Lighting: Enclosed and Gasketed — Area — LED/Induction

165 Watt Pendant with Globe,
Guard and Reflectors

16.38"/
416.1 mm  Dia.
16.63"/
422.4 mm  Dia.

55 Watt

Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

Mercmaster™ III Induction Luminaire Dimensions

Enclosed and Gasketed. For Hazardous and Adverse Locations

Pendant (Rigid or Flex)

Pendant Cone

12.06"/
306.3 mm

Ceiling
13.62"/
346.9 mm
12.06"/
306.3 mm

12.06"/
306.3 mm
1.17"/
29.7 mm

5.59"/
142.0 mm
1.75"/
44.5 mm

25° Stanchion

5”/
9.2 0 mm
.
5
23

25°

0”/
2.0 mm
8
.
50
”/
.03 m
12 .6 m
5
30

9.79”/
248.7 mm

SET SCREW

Wall Mount
17.00"/
431.8 mm
10.93”/
277.6 mm

12.03”/
305.6 mm

12.03”/
305.6 mm

Lighting: Enclosed and Gasketed — Area — LED/Induction

t
Se w
re
Sc

17.23”/
437.6 mm

Lighting

/
27”
15. .9 mm
7
38

90° Stanchion

3.36"/
85.3 mm
1.57"/
39.9 mm

9”/
7.5 8 mm
.
2
19

4.06"/
103.1 mm
2.03"/
51.6 mm

Standard Polyester Reflector

30º Angle Polyester Reflector

Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

Deep Dome

1047

PCD2 Series Factory Sealed Hazardous Location Photocontrol
For Use in Class I, Division 2, Groups A, B, C, D Locations

Maintains Class I, Division 2 rating for Mercmaster III – Low Profile, Mercmaster III, and Mercmaster III – 400 Series Luminaires, Mercmaster LED.
Class I, Division 2, Groups A, B, C, D
NEMA 4X

Applications

Materials

•	 Encapsulated photocontrol provides automatic dusk-to-dawn
lighting control in Class I, Division 2 locations.
•	 Typical applications include walkways, security areas and any
other outdoor lighting application.
•	 For use with Mercmaster III – Low Profile, Mercmaster III, and
Mercmaster III – 400 Series Luminaires.
•	 For remote mounting in FS Boxes.

•	 Encapsulated with epoxy sealing compound
•	 FS: aluminum

Certifications and Compliances
•	 UL Standard: 1604 ­– Hazardous (Classified) Locations
•	 cULus Recognized

Lighting: Enclosed and Gasketed — Area — LED/Induction

Lighting

Features
•	 Factory sealed design eliminates the need for an explosionproof
enclosure.
•	 Can be easily installed in the field.
•	 Solid state design for performance and reliability.
•	 Available for 120, 208, 240, or 277 volts.
•	 50-400 W HID, incandescent or fluorescent, 50/60 Hz.
•	 1000 VA Voltage/Ampere
•	 Minimum time delay: 15 seconds to eliminate nuisiance tripping.
•	 Provided with (3) 18AWG stranded  leads 6”/152.4mm in length.
•	 Will fit through standard 1/2” knockout.

Factory-Installed Photocontrol

Dimensions

Add to fixture catalog after voltage; i.e.: KPWBL1075MTH1.

Mercmaster III wall mounting hood
with photocontrol installed shown

Voltage Range

Suffix Designation

120 V, 50/60 Hz

H1

208 V, 50/60 Hz

H2

240 V, 50/60 Hz

H3

277 V, 50/60 Hz

H4
1.13”
28.7
mm
1.13”
28.7 mm

Photocontrol in FS Cover for Use with FS/FD Box

Supplied with two stainless steel screws. For neoprene gasket, order catalog number FS-GKR-1N.

Voltage Range

Catalog Number

120V, 50/60 Hz

FSKA-PC120D2

208-277V, 50/60 Hz

FSKA-PC247D2

1.375”
34.9
mm
1.375”
34.9 mm
2.56”
65.0
mm
2.56”
65.0 mm

1.13”
28.7 mm

Photocontrol for Field Installation
Max. Current

Catalog Number

120 V, 50/60 Hz

Voltage Range

8.3 Amp

PC120D2

208-277 V, 50/60 Hz

3.5 Amp

34.9 mm
PC247D2

2.56”
65.0 mm

1048

1.375”

0.69”
17.5 mm
1.19”
30.2 mm

1.94”
49.2 mm

Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

Mercmaster™ III Induction Luminaire 55 W Photometric Data
Enclosed and Gasketed. For Hazardous and Adverse Locations

Total Luminaire Efficiency = 78%
CIE Type – General Diffuse

REPORT NUMBER: MLBR55QL
Lamps: 55 W QL lamp with Globe only
Coefficients of Utilization - Zonal Cavity Method
Effective Floor Cavity Reflectance 0.20

110-120

254.71

120-130
130-140
140-150
150-160
160-170
170-180

184.93
87.45
16.45
16.70
0.05
0.00

Total Luminaire Efficiency = 68.6%
CIE Type – Direct
Spacing Criteria: 1.40

70

50

30

10

0

% Walls Rw

70 50 30 10

70 50 30 10

50 30 10

50 30 10

50 30 10

0

85
73
65
59
53
48
44
41
38
35
33

79
68
60
54
49
44
41
38
35
32
30

69
54
45
38
33
29
26
24
21
19
18

59
45
37
32
28
24
22
20
18
16
15

50
37
31
26
22
20
18
16
15
13
12

0
1
2
3
4
5
6
7
8
9
10

85
68
57
49
43
38
33
30
27
24
22

85
64
51
42
35
30
26
23
20
18
16

85
59
45
36
29
24
21
18
15
14
12

79
63
53
45
39
35
31
28
25
23
21

79
59
47
39
33
28
24
21
19
17
15

79
55
42
33
27
23
19
17
14
13
11

69
51
40
33
28
24
21
18
16
14
13

69
48
36
29
23
20
17
14
12
11
10

59
43
34
28
23
20
17
15
14
12
11

59
40
31
24
20
16
14
12
10
9
8

50
35
28
23
19
16
14
12
11
10
9

50
34
25
20
16
13
11
10
9
8
7

46
30
22
17
13
11
9
8
7
6
5

Zonal Lumen Summary
Zone
0-30
0-40
0-60
0-90

Lumens
173.63
318.76
743.26
1597.39

% Lamp
5.0
9.1
21.2
45.6

% Fixture
6.4
11.7
27.2
58.5

Zone
90-120
90-130
90-150
90-180
0-180

Lumens
842.61
1027.54
1131.69
1132.40
2729.80

% Lamp
24.1
29.4
32.3
32.4
78.0

% Fixture
30.9
37.6
37.6
41.5
100.0

REPORT NUMBER: MLBR55QLST
Lamps: 55 W QL lamp with Standard Dome Reflector
Coefficients of Utilization - Zonal Cavity Method
Effective Floor Cavity Reflectance 0.20

Zone
0-10
10-20
20-30
30-40
40-50
50-60
60-70
70-80
80-90
90-100
100-110

Lumens
53.72
151.63
237.12
314.91
369.39
394.66
389.48
306.69
141.30
20.15
4.14

110-120

4.10

120-130
130-140
140-150
150-160
160-170
170-180

5.12
4.61
1.93
0.37
0.11
0.04

Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

% Ceiling Rcc

80

70

50

30

10

0

% Walls Rw

70 50 30 10

70 50 30 10

50 30 10

50 30 10

50 30 10

0

81
72
67
58
52
48
44
41
38
35
33

79
70
62
56
51
46
43
39
37
34
32

76
63
53
46
40
35
32
29
26
24
22

72
60
51
44
38
34
30
28
25
23
21

69
57
48
42
37
32
29
23
24
22
21

0
1
2
3
4
5
6
7
8
9
10

81
68
57
49
43
38
34
31
28
25
23

81
64
52
43
36
31
27
24
21
19
17

81
61
47
38
31
26
22
19
17
15
14

79
66
56
48
42
37
33
30
27
25
23

79
63
51
42
36
31
27
24
21
19
17

79
60
46
37
31
26
22
19
17
15
14

76
60
49
41
34
30
26
23
21
19
17

76
57
45
36
30
25
22
19
17
15
13

72
58
47
39
33
29
25
22
20
18
17

72
55
44
35
29
25
21
19
17
15
13

69
55
45
38
32
28
25
22
20
18
16

69
54
43
35
29
25
21
18
16
15
13

67
52
14
33
27
23
20
17
15
13
12

Zonal Lumen Summary
Zone
0-30
0-40
0-60
0-90

Lumens
442.48
757.38
1521.42
2358.89

% Lamp
12.6
21.6
43.5
67.4

% Fixture
18.4
31.6
63.4
98.3

Zone
90-120
90-130
90-150
90-180
0-180

Lumens
28.39
33.51
40.05
40.58
2399.47

% Lamp
0.8
1.0
1.1
1.2
68.6

% Fixture
1.2
1.4
1.4
1.7
100.0

1049

Lighting: Enclosed and Gasketed — Area — LED/Induction

Lumens
20.62
57.15
95.87
145.23
191.57
232.82
266.04
288.86
299.24
299.72
288.18

80

Lighting

Zone
0-10
10-20
20-30
30-40
40-50
50-60
60-70
70-80
80-90
90-100
100-110

% Ceiling Rcc

Mercmaster™ III Induction Luminaire 55 W Photometric Data
Enclosed and Gasketed. For Hazardous and Adverse Locations

Total Luminaire Efficiency = 61.1%
CIE Type – Direct
Spacing Criteria: 1.80

REPORT NUMBER: MLBR55QLAN
Lamps: 55 W QL lamp with 30° Angle Dome Reflector
Coefficients of Utilization - Zonal Cavity Method

Lighting: Enclosed and Gasketed — Area — LED/Induction

Lighting

Effective Floor Cavity Reflectance 0.20

Zone
0-10
10-20
20-30
30-40
40-50
50-60
60-70
70-80
80-90
90-100
100-110

Lumens
42.29
134.14
213.06
282.99
314.71
306.62
275.85
232.10
171.94
100.63
40.56

110-120

9.45

120-130
130-140
140-150
150-160
160-170
170-180

3.75
2.43
0.97
0.34
0.25
0.06

Total Luminaire Efficiency = 59.2%
CIE Type – Direct
Spacing Criteria: 1.58

% Ceiling Rcc

80

70

50

30

10

0

% Walls Rw

70 50 30 10

70 50 30 10

50 30 10

50 30 10

50 30 10

0

72
63
57
51
47
43
39
36
34
31
29

69
61
55
49
45
41
38
35
32
30
28

65
54
46
40
35
31
28
25
23
21
20

62
51
43
38
33
29
27
24
22
20
19

58
48
41
35
31
28
25
23
21
19
18

0
1
2
3
4
5
6
7
8
9
10

72
59
51
44
38
34
30
27
25
23
21

72
56
46
38
32
28
25
22
19
18
16

72
53
42
34
28
24
20
18
16
14
13

69
58
49
43
37
33
30
27
24
22
20

69
55
45
37
32
27
24
21
19
17
16

69
52
41
33
27
23
20
18
15
14
12

65
52
42
35
30
26
23
21
18
17
15

65
49
39
32
27
23
20
17
15
13
12

62
49
40
34
29
25
22
20
18
16
15

62
47
37
31
26
22
19
17
15
13
12

58
46
38
32
28
24
21
19
17
16
14

58
45
36
30
25
21
18
16
14
13
12

57
42
34
28
23
20
17
15
13
12
10

Zonal Lumen Summary
Zone
0-30
0-40
0-60
0-90

Lumens
394.49
677.48
1298.80
1978.69

% Lamp
11.3
19.4
37.1
56.5

% Fixture
18.5
31.7
60.8
92.6

Zone
90-120
90-130
90-150
90-180
0-180

Lumens
150.64
154.39
157.79
158.45
2137.14

% Lamp
4.3
4.4
4.5
4.5
61.1

% Fixture
7.0
7.2
7.2
7.4
100.0

REPORT NUMBER: MLBR55QLHB
Lamps: 55 W QL lamp with High Bay Reflector
Coefficients of Utilization - Zonal Cavity Method
Effective Floor Cavity Reflectance 0.20

Zone
0-10
10-20
20-30
30-40
40-50
50-60
60-70
70-80
80-90
90-100
100-110
110-120

Lumens
64.78
196.79
326.97
437.52
470.90
345.47
167.60
52.79
7.73
0.00
0.00
0.14

120-130
130-140
140-150
150-160
160-170
170-180

0.26
0.16
0.24
0.00
0.04
0.02

1050

% Ceiling Rcc

80

70

50

30

10

0

% Walls Rw

70 50 30 10

70 50 30 10

50 30 10

50 30 10

50 30 10

0

70
65
60
55
50
46
43
40
37
34
32

69
64
58
54
49
45
42
39
36
34
31

66
59
52
47
42
37
34
31
28
26
24

63
57
51
45
40
36
33
30
27
25
23

60
55
49
44
39
35
32
29
26
24
22

0
1
2
3
4
5
6
7
8
9
10

70
63
56
49
44
39
35
32
29
27
24

70
61
52
45
39
34
30
27
24
22
20

70
59
49
41
35
30
27
23
21
19
17

69
62
54
48
43
39
35
31
29
26
24

69
60
51
44
39
34
30
27
24
22
20

69
58
48
41
35
30
26
23
21
19
17

66
57
40
43
38
33
29
26
24
21
19

66
56
47
40
35
30
26
23
21
18
17

63
55
48
42
37
32
29
26
23
21
19

63
54
46
40
34
30
26
23
20
18
17

60
54
47
41
36
32
28
25
23
21
19

60
53
45
39
34
29
26
23
20
18
17

59
51
44
38
32
28
25
22
19
17
15

Zonal Lumen Summary
Zone
0-30
0-40
0-60
0-90

Lumens
588.53
1026.05
1842.43
2070.54

% Lamp
16.8
29.3
52.6
59.2

% Fixture
28.4
49.5
88.9
100.0

Zone
90-120
90-130
90-150
90-180
0-180

Lumens
0.14
0.41
0.81
0.87
2071.41

% Lamp
0.0
0.0
0.0
0.0
59.2

% Fixture
0.0
0.0
0.0
0.0
100.0

Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

Mercmaster™ III Induction Luminaire 85 W Photometric Data
Enclosed and Gasketed. For Hazardous and Adverse Locations

Total Luminaire Efficiency = 78.4%
CIE Type – General Diffuse

REPORT NUMBER: MLBR85QL
Lamps: 85 W QL lamp with Globe only
Coefficients of Utilization - Zonal Cavity Method
Effective Floor Cavity Reflectance 0.20
% Ceiling Rcc
% Walls

110-120

439.16

120-130

318.85

130-140
140-150
150-160
160-170
170-180

150.78
28.79
1.15
0.08
0.00

Total Luminaire Efficiency = 69%
CIE Type – Direct
Plane

Spacing
Criteria

0-180

1.40

90-270

1.40

Diagonal

1.58

110-120

7.07
8.83
7.95
3.33
0.64
0.19
0.07

10

0

50 30 10

50 30 10

50 30 10

0

0
1
2
3
4
5
6
7
8
9
10

86
74
66
59
53
49
45
41
38
35
33

80
68
60
54
49
45
41
38
35
33
30

69
54
45
39
34
30
26
24
21
20
18

59
46
38
32
28
25
22
20
18
16
15

50
38
31
26
23
20
18
16
15
13
12

86
69
58
49
43
38
34
30
27
25
23

86
64
51
42
35
30
26
23
20
18
16

86
60
46
36
29
25
21
18
16
14
12

80
64
53
46
40
35
31
28
25
23
21

80
59
47
39
33
28
24
21
19
17
15

80
56
42
34
27
23
19
17
14
13
11

69
51
41
33
28
24
21
18
16
15
13

69
48
36
29
24
20
17
14
12
11
10

59
43
34
28
23
20
17
15
14
12
11

59
41
31
24
20
17
14
12
11
9
8

50
36
28
23
19
16
14
13
11
10
9

50
34
25
20
16
13
11
10
9
8
7

46
30
22
17
13
11
9
8
7
6
5

Lumens
299.37
549.76
1281.48
2754.13

% Lamp
5.0
9.2
21.4
45.9

% Fixture
6.4
11.7
27.2
58.5

Zone
90-120
90-130
90-150
90-180
0-180

Lumens
1452.77
1771.62
1951.19
1952.42
4706.55

% Lamp
24.2
29.5
32.5
32.5
78.4

% Fixture
30.9
37.6
37.6
41.5
100.0

REPORT NUMBER: MLBR85QLST
Lamps: 85 W QL lamp with Standard Dome Reflector
Coefficients of Utilization - Zonal Cavity Method
Effective Floor Cavity Reflectance 0.20
% Ceiling Rcc

Lumens
92.63
261.43
408.83
542.94
636.87
680.44
671.51
528.78
243.62
34.74
7.14

120-130
130-140
140-150
150-160
160-170
170-180

30

70 50 30 10

Zonal Lumen Summary
Zone
0-30
0-40
0-60
0-90

% Walls
Zone
0-10
10-20
20-30
30-40
40-50
50-60
60-70
70-80
80-90
90-100
100-110

50

70 50 30 10

Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

80

70

50

30

10

0

Rw

70 50 30 10

70 50 30 10

50 30 10

50 30 10

50 30 10

0

0
1
2
3
4
5
6
7
8
9
10

82
73
65
58
53
48
44
41
38
35
33

80
70
63
56
51
47
43
40
37
34
32

76
63
54
46
40
36
32
29
26
24
22

72
60
51
44
38
34
31
28
25
23
21

69
58
49
42
37
33
29
27
24
22
21

82
68
58
50
43
38
34
31
28
25
23

82
65
52
43
36
31
27
24
21
19
18

82
61
47
38
31
26
22
19
17
15
14

80
67
56
48
42
37
33
30
27
25
23

80
63
51
42
36
31
27
24
21
19
17

80
60
47
37
31
26
22
19
17
15
14

76
60
49
41
35
30
26
23
21
19
17

76
58
45
37
30
25
22
19
17
15
13

72
58
47
39
34
29
25
23
20
18
17

72
56
44
36
30
25
22
19
17
15
13

69
56
46
38
33
28
25
22
20
18
16

69
54
43
35
29
25
21
19
16
15
13

68
52
41
33
27
23
20
17
15
13
12

Zonal Lumen Summary
Zone
0-30
0-40
0-60
0-90

Lumens
762.89
1305.83
2623.14
4067.06

% Lamp
12.7
21.8
43.7
67.8

% Fixture
18.4
31.6
63.4
98.3

Zone
90-120
90-130
90-150
90-180
0-180

Lumens
48.95
57.78
69.06
69.96
4137.02

% Lamp
0.8
1.0
1.2
1.2
69.0

% Fixture
1.2
1.4
1.4
1.7
100.0

1051

Lighting: Enclosed and Gasketed — Area — LED/Induction

Lumens
35.55
98.53
165.29
250.39
330.30
401.42
458.68
498.03
515.94
516.75
496.86

70

Rw

Lighting

Zone
0-10
10-20
20-30
30-40
40-50
50-60
60-70
70-80
80-90
90-100
100-110

80

Mercmaster™ III Induction Luminaire 85 W Photometric Data
Enclosed and Gasketed. For Hazardous and Adverse Locations

Total Luminaire Efficiency = 61.4%
CIE Type – Direct
Plane

Spacing
Criteria

0-180

1.80

90-270

1.44

Diagonal

1.54

REPORT NUMBER: MLBR85QLAN
Lamps: 85 W QL lamp with 30° Angle Dome Reflector
Coefficients of Utilization - Zonal Cavity Method
Effective Floor Cavity Reflectance 0.20
% Ceiling Rcc

Lighting: Enclosed and Gasketed — Area — LED/Induction

Lighting

% Walls
Zone
0-10
10-20
20-30
30-40
40-50
50-60
60-70
70-80
80-90
90-100
100-110

Lumens
81.53
231.27
367.34
487.91
542.61
528.65
475.60
400.17
296.45
173.50
69.93

110-120

16.29

120-130

6.47

130-140
140-150
150-160
160-170
170-180

4.19
1.67
0.59
0.44
0.10

Total Luminaire Efficiency = 59.5%
CIE Type – Direct
Plane

Spacing
Criteria

0-180

1.58

90-270

1.58

Diagonal

1.58

110-120

0.25
0.46
0.28
0.41
0.00
0.07
0.04

1052

50

30

10

0

70 50 30 10

70 50 30 10

50 30 10

50 30 10

50 30 10

0

0
1
2
3
4
5
6
7
8
9
10

72
64
57
52
47
43
39
36
34
32
30

70
61
55
49
45
41
38
35
33
30
29

66
54
46
40
35
31
28
25
23
21
20

62
51
44
38
33
30
27
24
22
20
19

58
48
41
36
31
28
25
23
21
19
18

72
60
51
44
39
34
31
28
25
23
21

72
56
46
38
33
28
25
22
20
18
16

72
53
42
34
28
24
20
18
16
14
13

70
58
49
43
38
33
30
27
24
22
21

70
55
45
37
32
28
24
21
19
17
16

70
52
41
33
28
23
20
18
16
14
12

66
52
43
36
31
26
23
21
19
17
15

66
50
39
32
27
23
20
17
15
14
12

62
49
40
34
29
25
22
20
18
16
15

62
47
38
31
26
22
19
17
15
13
12

58
46
38
32
28
24
21
19
17
16
14

58
45
36
30
25
21
19
16
14
13
12

57
43
34
28
23
20
17
15
13
12
11

Lumens
680.15
1168.06
2239.32
3411.54

% Lamp
11.3
19.5
37.3
56.9

% Fixture
18.5
31.7
60.8
92.6

Zone
90-120
90-130
90-150
90-180
0-180

Lumens
259.73
266.19
272.06
273.19
2684.73

% Lamp
4.3
4.4
4.5
4.6
61.4

% Fixture
7.0
7.2
7.2
7.4
100.0

REPORT NUMBER: MLBR85QLHB
Lamps: 85 W QL lamp with High Bay Reflector
Coefficients of Utilization - Zonal Cavity Method
Effective Floor Cavity Reflectance 0.20
% Ceiling Rcc

Lumens
111.69
339.29
563.74
754.34
811.90
595.64
288.96
91.02
13.32
0.00
0.00

120-130
130-140
140-150
150-160
160-170
170-180

70

Rw

Zonal Lumen Summary
Zone
0-30
0-40
0-60
0-90

% Walls
Zone
0-10
10-20
20-30
30-40
40-50
50-60
60-70
70-80
80-90
90-100
100-110

80

80

70

50

30

10

0

Rw

70 50 30 10

70 50 30 10

50 30 10

50 30 10

50 30 10

0

0
1
2
3
4
5
6
7
8
9
10

71
66
60
55
51
47
43
40
37
35
32

69
64
59
54
49
45
42
39
36
34
32

66
59
53
47
42
38
34
31
28
26
24

63
57
51
45
40
36
33
30
27
25
23

61
55
49
44
39
35
32
29
27
24
23

71
63
56
50
44
39
35
32
29
27
25

71
61
52
45
39
34
30
27
24
22
20

71
59
49
42
35
31
27
24
21
19
17

69
62
55
49
43
39
35
32
29
26
24

69
60
51
44
39
34
30
27
24
22
20

69
58
49
41
35
30
27
23
21
19
17

66
58
50
43
38
33
30
26
24
22
20

66
56
48
40
35
30
26
23
21
19
17

63
56
49
42
37
33
29
26
23
21
19

63
55
46
40
34
30
26
23
21
18
17

61
54
47
41
36
32
29
26
23
21
19

61
53
45
39
34
29
26
23
20
18
17

59
52
44
38
33
28
25
22
19
17
16

Zonal Lumen Summary
Zone
0-30
0-40
0-60
0-90

Lumens
1014.71
1769.06
3176.60
3569.90

% Lamp
16.9
29.5
52.9
59.5

% Fixture
28.4
49.5
88.9
100.0

Zone
90-120
90-130
90-150
90-180
0-180

Lumens
0.25
0.70
1.39
1.50
3571.40

% Lamp
0.0
0.0
0.0
0.0
59.5

% Fixture
0.0
0.0
0.0
0.0
100.0

Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

Mercmaster™ III Induction Luminaire 165 W Photometric Data
Enclosed and Gasketed. For Hazardous and Adverse Locations

Total Luminaire Efficiency = 70.7%
CIE Type – General Diffuse

REPORT NUMBER: KPB165QLG
Lamps: 165 W QL lamp with Globe only
Coefficients of Utilization - Zonal Cavity Method
Effective Floor Cavity Reflectance 0.20
% Ceiling Rcc
% Walls

110-120

758.05

120-130
130-140
140-150
150-160
160-170
170-180

568.50
328.65
119.26
15.42
0.71
0.05

Total Luminaire Efficiency = 58.5%
CIE Type – Direct
Plane

Spacing
Criteria

0-180

1.34

90-270

1.34

Diagonal

1.56
Lumens
149.58
419.79
669.69
893.40
1052.06
1151.10
1157.87
920.80
462.02
95.45
12.02
10.92

120-130
130-140
140-150
150-160
160-170
170-180

11.39
11.34
5.50
1.16
0.07
0.12

30

10

0

70 50 30 10

50 30 10

50 30 10

50 30 10

0

0
1
2
3
4
5
6
7
8
9
10

77
66
59
53
48
44
40
37
34
32
30

72
61
54
49
44
40
37
34
31
29
27

62
49
40
34
30
26
23
21
19
17
16

53
41
34
28
25
22
19
17
16
15
13

45
33
27
23
20
17
16
14
13
12
11

77
62
52
44
38
34
30
27
24
22
20

77
57
46
38
32
27
23
20
18
16
14

77
54
41
32
26
22
19
16
14
12
11

72
57
48
41
36
31
28
25
22
20
19

72
53
42
35
29
25
22
19
17
15
13

72
50
38
30
24
20
17
15
13
11
10

62
46
36
30
25
21
18
16
14
13
12

62
43
33
26
21
17
15
13
11
10
9

53
38
30
25
21
18
15
14
12
11
10

53
36
27
22
17
15
12
11
9
8
7

45
32
25
20
17
14
12
11
10
9
8

45
30
22
18
14
12
10
8
7
7
6

41
26
19
15
11
9
8
7
6
5
4

Zonal Lumen Summary
Zone
0-30
0-40
0-60
0-90

Lumens
497.77
933.23
2229.28
4898.92

% Lamp
4.1
7.8
18.6
40.8

% Fixture
5.9
11.0
26.3
57.7

Zone
90-120
90-130
90-150
90-180
0-180

Lumens
2553.16
3121.65
3569.56
3585.75
8484.67

% Lamp
21.3
26.0
29.7
29.9
70.7

% Fixture
30.1
36.8
36.8
42.3
100.0

REPORT NUMBER: KPB165QLST
Lamps: 165 W QL lamp with Standard Dome Reflector
Coefficients of Utilization - Zonal Cavity Method
Effective Floor Cavity Reflectance 0.20
% Ceiling Rcc
% Walls

Zone
0-10
10-20
20-30
30-40
40-50
50-60
60-70
70-80
80-90
90-100
100-110
110-120

50

70 50 30 10

Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

80

70

50

30

10

0

Rw

70 50 30 10

70 50 30 10

50 30 10

50 30 10

50 30 10

0

0
1
2
3
4
5
6
7
8
9
10

69
61
55
49
44
41
37
34
32
30
28

68
59
53
47
43
39
36
33
31
29
27

64
53
45
39
34
30
27
24
22
20
18

61
51
43
37
32
28
25
23
21
19
18

59
48
41
35
31
27
24
22
20
19
17

69
58
49
42
36
32
29
26
23
21
20

69
54
44
36
30
26
23
20
18
16
15

69
51
40
32
26
22
19
16
14
13
11

68
56
47
41
35
31
28
25
23
21
19

68
53
43
35
30
26
22
20
18
16
14

68
50
39
31
26
21
18
16
14
12
11

64
51
41
34
29
25
22
19
17
16
14

64
49
38
30
25
21
18
16
14
12
11

61
49
40
33
28
24
21
19
17
15
14

61
47
37
30
25
21
18
16
14
12
11

59
47
38
32
27
23
21
18
16
15
14

59
45
36
29
24
20
18
15
14
12
11

57
44
34
27
23
19
16
14
12
11
10

Zonal Lumen Summary
Zone
0-30
0-40
0-60
0-90

Lumens
1239.06
2132.46
4335.62
6876.32

% Lamp
10.3
17.8
36.1
57.3

% Fixture
17.6
30.4
61.7
97.9

Zone
90-120
90-130
90-150
90-180
0-180

Lumens
118.39
129.78
146.62
147.97
7024.28

% Lamp
1.0
1.1
1.2
1.2
58.5

% Fixture
1.7
1.8
1.8
2.1
100.0

1053

Lighting: Enclosed and Gasketed — Area — LED/Induction

Lumens
57.43
158.04
282.31
435.46
580.50
715.54
829.63
904.70
935.31
924.84
870.28

70

Rw

Lighting

Zone
0-10
10-20
20-30
30-40
40-50
50-60
60-70
70-80
80-90
90-100
100-110

80

Mercmaster™ III Induction Luminaire 165 W Photometric Data
Enclosed and Gasketed. For Hazardous and Adverse Locations

Total Luminaire Efficiency = 61.4%
CIE Type – Direct
Plane

Spacing
Criteria

0-180

1.80

90-270

1.44

Diagonal

1.54

REPORT NUMBER: KPB165QLAN
Lamps: 165 W QL lamp with 30° Angle Dome Reflector
Coefficients of Utilization - Zonal Cavity Method
Effective Floor Cavity Reflectance 0.20
% Ceiling Rcc

Lighting: Enclosed and Gasketed — Area — LED/Induction

Lighting

% Walls
Zone
0-10
10-20
20-30
30-40
40-50
50-60
60-70
70-80
80-90
90-100
100-110
110-120

Lumens
163.07
462.54
734.69
975.82
1085.22
1057.29
951.20
800.34
592.90
347.00
139.87
32.59

120-130
130-140
140-150
150-160
160-170
170-180

12.93
8.39
3.34
1.19
0.88
0.20

Total Luminaire Efficiency = 61.6%
CIE Type – Direct
Plane

Spacing
Criteria

0-180

1.64

90-270

1.64

Diagonal

1.62
Lumens
216.27
655.22
1103.32
1536.15
1689.60
1298.60
664.63
201.70
26.23
0.27
0.00

110-120

0.00

120-130
130-140
140-150
150-160
160-170
170-180

0.00
0.00
0.00
0.00
0.00
0.00

1054

70

50

30

10

0

Rw

70 50 30 10

70 50 30 10

50 30 10

50 30 10

50 30 10

0

0
1
2
3
4
5
6
7
8
9
10

72
64
57
52
47
43
39
36
34
32
30

70
61
55
49
45
41
38
35
33
30
29

66
54
46
40
35
31
28
25
23
21
20

62
51
44
38
33
30
27
24
22
20
19

58
48
41
36
31
28
25
23
21
19
18

72
60
51
44
39
34
31
28
25
23
21

72
56
46
38
33
28
25
22
20
18
16

72
53
42
34
28
24
20
18
16
14
13

70
58
49
43
38
33
30
27
24
22
21

70
55
45
37
32
28
24
21
19
17
16

70
52
41
33
28
23
20
18
16
14
12

66
52
43
36
31
26
23
21
19
17
15

66
50
39
32
27
23
20
17
15
14
12

62
49
40
34
29
25
22
20
18
16
15

62
47
38
31
26
22
19
17
15
13
12

58
46
38
32
28
24
21
19
17
16
14

58
45
36
30
25
21
19
16
14
13
12

57
43
34
28
23
20
17
15
13
12
11

Zonal Lumen Summary
Zone
0-30
0-40
0-60
0-90

Lumens
1360.30
2336.12
4478.63
6823.08

% Lamp
11.3
19.5
37.3
56.9

% Fixture
18.5
31.7
60.8
92.6

Zone
90-120
90-130
90-150
90-180
0-180

Lumens
519.46
532.39
544.12
546.38
7369.46

% Lamp
4.3
4.4
4.5
4.6
61.4

% Fixture
7.0
7.2
7.2
7.4
100.0

REPORT NUMBER: KPB165QLHB
Lamps: 165 W QL lamp with High Bay Reflector
Coefficients of Utilization - Zonal Cavity Method
Effective Floor Cavity Reflectance 0.20
% Ceiling Rcc
% Walls

Zone
0-10
10-20
20-30
30-40
40-50
50-60
60-70
70-80
80-90
90-100
100-110

80

80

70

50

30

10

0

Rw

70 50 30 10

70 50 30 10

50 30 10

50 30 10

50 30 10

0

0
1
2
3
4
5
6
7
8
9
10

73
68
62
57
52
48
44
41
38
35
33

72
66
61
55
51
47
43
40
37
34
32

68
61
54
48
43
38
34
31
28
26
24

66
59
52
46
41
37
33
30
28
25
23

63
57
50
45
40
36
32
29
27
25
23

73
65
58
51
45
40
36
33
30
27
25

73
63
54
46
40
35
31
27
24
22
20

73
61
51
42
36
31
27
24
21
19
17

72
64
56
50
44
40
36
32
29
27
25

72
62
53
46
39
35
30
27
24
22
20

72
60
50
42
36
31
27
24
21
19
17

68
60
51
44
39
34
30
27
24
22
20

68
58
49
41
35
30
27
23
21
19
17

66
58
50
43
38
33
29
26
24
21
19

66
56
48
41
35
30
26
23
21
18
17

63
56
48
42
37
33
29
26
23
21
19

63
55
47
40
34
30
26
23
20
18
17

62
53
45
39
33
29
25
22
19
17
15

Zonal Lumen Summary
Zone
0-30
0-40
0-60
0-90

Lumens
1974.81
3510.96
6499.16
7391.72

% Lamp
16.5
29.3
54.2
61.6

% Fixture
26.7
47.5
87.9
100.0

Zone
90-120
90-130
90-150
90-180
0-180

Lumens
0.27
0.27
0.27
0.27
7391.99

% Lamp
0.0
0.0
0.0
0.0
61.6

% Fixture
0.0
0.0
0.0
0.0
100.0

Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

Mercmaster™ III Low Profile Compact Fluorescent Luminaires
Enclosed and Gasketed. For Hazardous and Wet Locations

Compact Fluorescent listed for simultaneous exposure to combustible dusts and flammable gases or vapors.
Class I, Division 2, Groups A, B, C, D
Class I, Zone 2, AEx nA nR IIC (Z2)
Class I, Zone 2, Ex nR IIC (Z) V

Class II, Division 1 and 2, Groups E, F, G
Class III
Simultaneous Exposure (Class I, Division 2/
Class II, Division 1)

Fixtures Outside Type (Salt Water)
Type 4X
IP66

Applications
•	 Enclosed and gasketed fixtures suitable for use in marine
and wet locations, and in a wide range of industrial, chemical
processing and other areas where flammable gases and vapors
or combustible dusts are present under conditions defined
by the National Electrical Code as Class I, Division 2; Class II,
Division 1 and 2; and Class III. The method of protection for
the Zone 2 Mercmaster is AEx nA nR – Restricted Breathing/
Nonsparking.
•	 For use in areas of low clearance, low ceiling heights or where
fixture weights must be minimized.
•	 Suited for use in non-hazardous locations where severe
weather conditions, excessive moisture, dirt, dust or corrosive
atmospheres are present.
•	 Typical applications include oil refineries, pulp and paper mills,
chemical plants, food-processing areas, inspection facilities,
foundries, power plants, storage areas, waste and sewage
treatment, parking garages, and other areas where dust, water,
dirt and rough usage are a problem.

Features

Ceiling Mount Fixture with
Prismatic Glass Refractor

Standard Materials
•	 Standard dome or 30° angle reflectors: highly reflective
fiberglass reinforced white polyester to provide strength,
corrosion resistance and excellent photometrics
•	 Fixture housing, mounting hoods, and guards: die-cast, 	
copperfree (4/10 of 1% max.) aluminum with epoxy finish for
corrosion resistance
•	 Exposed hardware: stainless steel. Latch assemblies have
stainless steel bolt and captive nut; reflectors and guards attach
with stainless steel screws threading into stainless steel inserts
•	 Globes and glass refractors: heat-resistant prismatic glass
•	 Polymeric refractor: spun aluminum reflector and a lens made of
an engineered thermoplastic

Standard Finishes
Options
•	 Fuse can be field installed. Kits include fuse block, wire
connectors and screws for attachment to mounting hood.
— Fixtures with fuses do not comply with UL 1598A for marine
listing
— Canadian Electrical Code does NOT allow fusing in
hazardous locations V
•	 Guards with gray epoxy painted to match fixtures, supplied with
stainless steel screws. Add suffix -G.
•	 Reflectors are available as standard dome and 30° angle
polyester. Order separately.

Certifications and Compliances
•	 UL Standard: UL 1598, UL 1598A, UL 844, UL 60079-0, UL
60079-15
•	 UL Listed: E10444
•	 CSA Standard: C22.2 No. 250, C22.2 No. 137, CAN E60079-0,
CAN E60079-15
•	 CSA Certified: 025428

1055

Lighting: Enclosed and Gasketed — Area — Fluorescent

•	 Epoxy powder coat finish electrostatically applied for complete,
uniform surface protection

V CSA Certification Only.
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

Lighting

•	 Energy-efficient, compact fluorescent light sources possess
superior lamp efficiency.
•	 Fluorescent provides long lamp life, thereby reducing 	
relamping costs.
•	 “Instant on” nature of this electronically ballasted fluorescent
eliminates the possibility of an extended blackout due to a
momentary power dip.
•	 High efficacies (up to 75 lumens per Watt) offer a desirable 	
low-glare/instant-on alternative to low wattage HID sources.
•	 High output under widely varying conditions: Greater than 90%
of rated lumens in ambient temperatures from 23 °F to 130 °F /
-5 °C to 54 °C.
•	 Excellent color rendering (82 CRI) makes it the best choice for
food processing and inspection facilities.
•	 A wide variety of lamp wattages: 	
26 W, 32 W, 42 W, 52 W, 64 W, 84 W.
•	 Electronic ballast permits low operating costs with power factor
greater than 99%. Also allows flicker-free starting.
•	 Cold weather starting to a minimum temperature of 0°F/ -18°C.
•	 Fixtures are available for operation from an external 125 Vdc
source.
•	 Compact, light-weight low profile design creates ease of
installation and maintenance.
•	 Modular design, with multiple mounting hoods, optics and
reflectors, permits a wide array of fixtures to meet installation
and lighting needs.
•	 Body gaskets and optic gaskets are high temperature silicone
O-Rings that provide superior sealing.
•	 Mounting hoods have a high hinge for added safety during
installation and servicing.
•	 Choice of heat-resistant prismatic glass refractor (NEMA I, III
or V), heat-resistant clear globes, color globes or polymeric
refractors (NEMA II, III, IV or V). (Polymeric refractors are not
listed for Zone 2.)

Pendant Mount Fixture
with Glass Globe

Mercmaster™ III Low Profile Compact Fluorescent Luminaires
Enclosed and Gasketed. For Hazardous and Wet Locations

Compact Fluorescent listed for simultaneous exposure to combustible dusts and flammable gases or vapors.
Class I, Division 2, Groups A, B, C, D
Class I, Zone 2, AEx nA nR IIC (Z2)
Class I, Zone 2, Ex nR IIC (Z) V

Class II, Division 1 and 2, Groups E, F, G
Class III
Simultaneous Exposure (Class I, Division 2/
Class II, Division 1)

Fixtures Outside Type (Salt Water)
Type 4X
IP66

Illustrated Features
Ballast Assembly
Utilizing non-sparking components
avoiding the ignition of gases or vapors
that may be present (nA).

Lighting: Enclosed and Gasketed — Area — Fluorescent

Lighting

Globe Chamber
Completely sealed from the ballast
housing and outside vapors/air (nA nR).

Vented Reflectors
Reflectors are thick, tough fiberglass-	
reinforced white polyester, vented for
cooler operation. Quickly attach with
furnished stainless steel screws.

Epoxy Finish
Ballast housing, hoods and guards are
copperfree aluminum with epoxy powder
coat finish.

Terminal Blocks (Zone 2)
A seven-point terminal block is provided
to facilitate wiring. Terminal block
accommodates wire size ranging from #8
to #24 AWG.

Photocell
Installs through knock-out in mounting
hoods except cone and ceiling mount. 	
Provides continuous on-off dusk-to-	
dawn control. Not for use in hazardous
(classified) areas. Hazardous location 	
rated photocells also available. See 	
Accessories page.

Stainless Steel Inserts
Ballast bodies have stainless steel
threaded inserts to receive stainless steel
screws for reflectors and guard. Prevents
"freezing”, allowing guards and reflectors
to be easily removed and replaced at any
time, without damage to the housing.

Hood/Ballast Gasket
Silicone rubber gasket seals out moisture,
dirt and dust. Stays flexible, withstands
high temperatures. Closure design
assures uniform gasket compression.
Electrical Protection
Ground wire provided to bond mounting
hood to ballast housing.

Cooler Operating Cone Hood
Larger sloped surface sheds dusts, dirt
and combustible fibers providing better
heat dissipation.

Prismatic Glass Globes and Refractors
Heat-resistant globes and glass refractors
and polymeric refractors thread directly
into ballast housing and seal against a 	
high temperature silicone rubber gasket.
(Polymeric refractors are not listed for
Zone 2 areas.)

Fuses
Two screws secure fuse kit to mounting
boss in any Mercmaster mounting hood.
Fuse included.
Stainless Steel Latch Assembly
Captive, stainless steel latch assembly 	
bolt and nut closes securely, resists attack 	
of corrosive atmospheres. Swing-away
design simplifies servicing.

"Safety" High
Hinge
Extra-high hinge
provides additional
protection against
accidental
ballast housing
disengagement
during installation
or maintenance.

V CSA Certification Only.

1056

Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

Mercmaster™ III Low Profile Compact Fluorescent Luminaire Family Tree
Enclosed and Gasketed. For Hazardous and Wet Locations

Compact Fluorescent listed for simultaneous exposure to combustible dusts and flammable gases or vapors.

Mounting Hoods

Mounting Hoods

Pendant
Pendant
KPA-75
KPA-75
KPA-100
KPA-100

Pendant
PendantCone
Cone
KPCH-75
KPCH-75
KPCH-100
KPCH-100

Ceiling
Ceiling

KPC-75
KPC-75
KPC-100
KPC-100

25°
25°Stanchion
Stanchion

90°90°Stanchion
Stanchion

KPS-125
KPS-75
KPS-100
KPS-150

KPST-125
KPST-75
KPST-100
KPST-150

Globe or Polymeric
Refractor
Ballast Housings
MLBG26FBU
(26 W)
Globe
or Polymeric
MLBG32FBU (32 W)
Refractor
MLBG42FBU (42 W)
Ballast
Housings
MLBG52FBU
(52 W)
MLBG32F
32W)
MLBG57FBU(26
(57&W)
V
MLBG64F
(52(64
& 64W)
MLBG64FBU
W)
MLBG84FBU (84 W)
MLBG114FBU (114 W) V

Ballast
Housing
Ballast
Housing

KPWB-75
KPWB-75
KPWB-100
KPWB-100

8” Glass Refractor
Ballast Housings
8"
Glass Refractor
MLBR26FBU (26 W)
Ballast
Housings
MLBR32FBU
(32 W)
MLBR26F(42
(26W)
MLBR42FBU
W)
MLBR32F(52
(32W)
MLBR52FBU
W)
MLBR52F
(52W)
MLBR57FBU
(57W)
V
MLBR64FBU
W)
MLBR64F(64
(64W)
MLBR84FBU (84 W)
MLBR114FBU (114 W) V

Polyester Reflectors

Polyester Reflectors

Polyester Reflectors

Standard
Standard Dome
Dome
CMR-4ST
CMR-4ST
30°
30°Angle
Angle
CMR-4AN
CMR-4AN

30°Angle
Angle
30°
KR2-AN
KR2-AN

Glass Refractors
Glass Refractors
NEMA I	
LPG-R1
NEMA
NEMA
III 	1 LPG-R1
LPG-R3
NEMA
NEMA
V 	 3 LPG-R3
LPG-R5
NEMA 5 LPG-R5

Polymeric Refractors
Polymeric
Refractors
NEMA
II 	 2 LPRF-2CP
LPRF-2CP
NEMA
NEMA
III 	 3 LPRF-3CP
LPRF-3CP
NEMA
NEMA
IV	 4 LPRF-4CP
LPRF-4CP
NEMA
NEMA
V	 5 LPRF-5CP
LPRF-5CP
NEMA

Aluminum Guard
Guard
Aluminum
GlobeGuard
Guard
Globe
KGU2
KGU2

Three-Way
Three-Way
Exit Sign
Exit
Sign

CJEXR
CJEXRN

Aluminum Guard
Aluminum
Guard
GlassRefractor
Refractor Guard
Glass
Guard
KRG2
KRG2

V CSA Certification Only.
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

1057

Lighting: Enclosed and Gasketed — Area — Fluorescent

Standard
Dome
Standard Dome
KR2-ST
KR2-ST

Lighting

Polyester Reflectors

GlassGlobes
Globes
Glass
Clear
VPGL-2HR
Clear	 VPGL-2HR
Amber
VPGL-2AM
Amber	 VPGL-2AM
Blue	
VPGL-2BL
Blue
VPGL-2BL
Green	
VPGL-2GR
Green VPGL-2GR
Red	
VPGL-2RE
Red
VPGL-2RE

Wall
WallMount
Mount

Mercmaster™ III Low Profile Compact Fluorescent Luminaires
Enclosed and Gasketed. For Hazardous and Wet Locations
Class I, Division 2, Groups A, B, C, D
Class I, Zone 2, AEx nA nR IIC (Z2)
Class I, Zone 2, Ex nR IIC (Z) V

Class II, Division 1 and 2, Groups E, F, G
Class III
Simultaneous Exposure (Class I, Division 2/
Class II, Division 1)

Fixtures Outside Type (Salt Water)
Type 4X
IP66

Order using catalog numbering guide below or select catalog number from tables on following pages.
Catalog Numbering Guide For Zone 2 Mercmaster III Compact Fluorescent Luminaires
ML
Series:
ML Mercmaster
III 	
Low Profile	

A

F

Lighting

2

G2

G

BU

L

Z2

Guard Options:
Lamp Options:
Hub Size:
2 - 3/4” NPT
G - Cast Guard
L - Lamp(s) included
3 - 1” NPT
(Glass Refractor
Blank - Lamp(s) 	
4 - 1-1/4” NPT 	
& Globe only)
excluded
Stanchion
N - No Guard
5 - 1-1/2” NPT 	
Stanchion
Wattage:
Voltage:
Suffix:
Optical Assembly: ➊
26 - One 26 Watt PL-T
BU - 120 to 277 V,
DP - Safety Cable
G2 - VPGL2HR Globe 	
32 - One 32 Watt PL-T
50/60 Hz	
SC - Safety Chain
(not for 57, 114 Watt)
42 - One 42 Watt PL-T
and 125 Vdc
Z2 - Zone 2 Suffix
G4 - VPGL4HR Globe 	
52 - Two 26 Watt PL-T
A5 - 347 V, 60 Hz V
(Required for 	
(57, 114 Watt only) V
57 - One 57 Watt PL-T V J1 - NEMA I Glass Refractor
AEx nA nR rating)
64 - Two 32 Watt PL-T
B - Battery Back-up ➍V
J3 - NEMA III Glass Refractor
84 - Two 42 Watt PL-T
(42 W max.)
J5 - NEMA V Glass Refractor
114 - Two 57 Watt PL-T V P2 - NEMA II Polymeric Refractor
C - Safety Cable V
F - Fused Mtg. Hood ➌V
P3 - NEMA III Polymeric
(Non-Haz. Loc. only)
Refractor
P - Non-Haz. Photocell
P4 - NEMA IV Polymeric
(Specify Voltage) V
Refractor
Q - Division 2 Haz.
P5 - NEMA V Polymeric
Photocell (Specify
Refractor
Voltage) V
T - Terminal Blocks V
V - Vibration Protection V
X - Appledapter ➋
Mounting Hood
Adapter V
Z - Zone 2 suffix
(required for 	
Ex nR) V

Lamp Type:
F - Fluorescent

Mounting Hood:
A - Pendant 	
(Rigid or Flexible)
C - Ceiling
D - Pendant Cone
R - 90º Stanchion
S - 25º Stanchion
W - Wall

Lighting: Enclosed and Gasketed — Area — Fluorescent

84

➊ Polymeric refractors suitable for Class II, Groups F & G; NEMA 4X; and Marine Type Electric Fixture Outside Type (Salt Water) only.
Reflectors ordered separately (for use with globe fixtures only): Standard Dome: KR2-ST 30-degree Angle: KR2-AN
➋ Appledapter is available for use with the pendant, ceiling and angled stanchion mounting only.
➌ Canadian Electrical Code does NOT allow fusing in hazardous locations V.
➍ Provides a minimum 90 minute back-up power supply in the case of a power loss. Will keep one lamp lit at approximately 50% of its full output (42 W
maximum) V.
V CSA Certification only.

1058

Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

Mercmaster™ III Low Profile Compact Fluorescent Luminaire Thermal Performance
Class I, Division 2; Class II, Division 1; Simultaneous Exposure to Hazardous Conditions
Temperature identification numbers of Mercmaster III Low Profile Fluorescent Fixtures
Class I, Division 2, Groups A, B, C, D
Class I, Zone 2, AEx nA nR IIC (Z2)
Class I, Zone 2, Ex nR IIC (Z) V

Lamp
Watts

Ambient
Temp
(°F/°C) ➊

Globe

26

104/40

T3

Class II, Division 1 and 2, Groups E, F, G
Class III
Simultaneous Exposure (Class I, Division 2/
Class II, Division 1)

Class I, Division 2
Globe &
Glass
Polymeric
Reflector Refractor Refractor
T3

T3

Class II, Division 1
Groups E, F and G ➋
Globe &
Glass
Polymeric
Reflector Refractor Refractor

Globe
T5

—

Fixtures Outside Type (Salt Water)
Type 4X
IP66

T5

T5

T6

Simultaneous Exposure
(Class I, Div 2 and Class II, Division 1)
Globe &
Glass
Polymeric
Globe
Reflector Refractor Refractor
T3

T3

T3

—

32

104/40

T3

T3

T3

—

T5

T5

T5

T6

T3

T3

T3

—

42

104/40

T3

T3

T3

—

T5

T5

T5

T6

T3

T3

T3

—

52

104/40

T2D

T2D

T3

—

T4A

T4A

T4A

T6

T2C

T2C

T2C

—

57 V

104/40

T2D

T2D

T3

—

T4A

T4A

T4A

T6

—

—

—

—

64

104/40

T2D

T2D

T3

—

T4A

T4A

T4A

T6

T2C

T2C

T2C

—

84

104/40

T2C

T2C

T2D

—

T3C

T3C

T3C

T6

T2B

T2B

T2B

—

114 V

104/40

T2C

T2C

T2D

—

T3C

T3C

T3C

T6

—

—

—

—

“T” Numbers Represent the Maximum Lamp Temperature for Class I, Division 2 Locations and
Maximum Surface Temperature Under Dust Blanket for Class II, Division 1 Locations.
“T” Number
Temp. Range (˚ºF)
Temp. Range (°C)

T1

350

325

T2

T2A

T2B

T2C

T2D

T3

T3A

T3B

T3C

T4

T4A

T5

664842
351450

619662
326-	
350

574617
301-	
325

538572
281-	
300

502536
261-	
280

448500
231-	
260

421446
216-	
230

394419
201215

358392
181-	
200

331356
166-	
180

322329
161165

277320
136160

250275
121135

214248
101-	
120

187212
86-	
100

T6
185
85
Lighting

Class I, Zone 2, AEx nA nR — Ex nR
Globe & Reflector
Refractor

Supply Wire Temp.
(°F/°C)

Ambient Temp.
(°F/°C)

Globe

26

167/75

104/40

T5

T5

T6

32

167/75

104/40

T5

T5

T6

42

167/75

104/40

T5

T5

T6

52

167/75

104/40

T5

T5

T6

57 V

167/75

104/40

T6

T6

T6

64

167/75

104/40

T5

T5

T6

84

167/75

104/40

T5

T5

T6

114 V

167/75

104/40

T6

T6

T6

Lighting: Enclosed and Gasketed — Area — Fluorescent

Lamp
Watts

“T” Numbers Represent the Maximum Surface Temperature for Luminaries with AEx nA nR Rating
“T”
Number

T1

T2

T3

T4

T5

T6

Temperature
Range (˚ºF)

574-842

394-572

277-392

214-275

187-212

185

Temperature
Range (°C)

301-450

201-300

136-200

101-135

86-100

85

➊ Use 167 °F/75 °C rated supply wire.
➋ Fixtures with Polymeric Refractor are listed for Groups F and G only.
V CSA Certification only.
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

1059

Mercmaster™ III Low Profile Compact Fluorescent Luminaires
Enclosed and Gasketed. For Hazardous and Wet Locations
High Power Factor Electronic Ballast (Min. P.F. 99%), PL-T Lamps.
Class I, Division 2, Groups A, B, C, D
Class I, Zone 2, AEx nA nR IIC (Z2)
Class I, Zone 2, Ex nR IIC (Z) V

Class II, Division 1 and 2, Groups E, F, G
Class III
Simultaneous Exposure (Class I, Division 2/
Class II, Division 1)

Lamp
Watts

Hub
Size
(Inches)

Fixtures Outside Type (Salt Water)
Type 4X
IP66

Catalog Numbers ➋➌
With Globe
➊➍

With Type V
8” Glass Refractor ➊➍➎

With Type V
Polymeric Refractor ➏

MLAF262G2N

MLAF262J5N

MLAF262P5N

Pendant — One Hub (Rigid or Flexible Mounting)
1 x 26 W
1 x 32 W
1 x 42 W
2 x 26 W
1 x 57 W
2 x 32 W
Shown with Glass Globe

2 x 42 W

Lighting

2 x 57 W

1

MLAF263G2N

MLAF263J5N

MLAF263P5N

3/4

MLAF322G2N

MLAF322J5N

MLAF322P5N

1

MLAF323G2N

MLAF323J5N

MLAF323P5N

3/4

MLAF422G2N

MLAF422J5N

MLAF422P5N

1

MLAF423G2N

MLAF423J5N

MLAF423P5N

3/4

MLAF522G2N

MLAF522J5N

MLAF522P5N

1
3/4
1
3/4

MLAF523G2N

MLAF523J5N

MLAF523P5N

MLAF572G4N V

MLAF572J5N V

MLAF572P5N V

MLAF573G4N V

MLAF572J5N V

MLAF572P5N V

MLAF642G2N

MLAF642J5N

MLAF642P5N

1

MLAF643G2N

MLAF643J5N

MLAF643P5N

3/4

MLAF842G2N

MLAF842J5N

MLAF842P5N

MLAF843G2N

MLAF843J5N

MLAF843P5N

3/4

MLAF1142G4N V

MLAF1142J5N V

MLAF1142P5N V

1

MLAF1143G4N V

MLAF1143J5N V

MLAF1143P5N V

3/4

MLDF262G2N

MLDF262J5N

MLDF262P5N

1

MLDF263G2N

MLDF263J5N

MLDF263P5N

3/4

MLDF322G2N

MLDF322J5N

MLDF322P5N

1

MLDF323G2N

MLDF323J5N

MLDF323P5N

1

Pendant Cone — One Hub (Rigid or Flexible Mounting)
1 x 26 W
1 x 32 W

Lighting: Enclosed and Gasketed — Area — Fluorescent

3/4

1 x 42 W
2 x 26 W
1 x 57 W
2 x 32 W
Shown with 8” Glass Refractor

2 x 42 W
2 x 57 W

3/4

MLDF422G2N

MLDF422J5N

MLDF422P5N

1

MLDF423G2N

MLDF423J5N

MLDF423P5N

3/4

MLDF522G2N

MLDF522J5N

MLDF522P5N

1

MLDF523G2N

MLDF523J5N

MLDF523P5N

3/4

MLDF572G4N V

MLDF572J5N V

MLDF572P5N V

1

MLDF573G4N V

MLDF573J5N V

MLDF573P5N V

3/4

MLDF642G2N

MLDF642J5N

MLDF642P5N

1

MLDF643G2N

MLDF643J5N

MLDF643P5N

3/4

MLDF842G2N

MLDF842J5N

MLDF842P5N

1

MLDF843G2N

MLDF843J5N

MLDF843P5N

3/4

MLDF1142G4N V

MLDF1142J5N V

MLDF1142P5N V

1

MLDF1143G4N V

MLDF1143J5N V

MLDF1143P5N V

➊ For fixtures with guard, substitute G for N before adding voltage suffix.
➋ Add voltage suffix -BU for 120 through 277 V, 50/60 Hz and 125 Vdc. Add voltage suffix -A5 for 347 V, 60 Hz.
➌ Add L after voltage suffix to include lamp.
➍ Add Z2 suffix for factory-sealed non-sparking/restricted breathing protection (Aex nA nR).
➎ To order fixture with NEMA Type I or III glass refractor, change J5 to J1 or J3 respectively.
➏ To order fixture with NEMA Type II, III, or IV polymeric refractor, change P5 to P2, P3 or P4 respectively. Polymeric refractor fixtures are UL Listed and CSA
Certified for Class II, Division 1 and 2, Groups F and G; Class III; Marine Outdoor Salt Water (UL1598A); NEMA 4X and CSA Type 4X.
V CSA Certification only.

1060

Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

Mercmaster™ III Low Profile Compact Fluorescent Luminaires
Enclosed and Gasketed. For Hazardous and Wet Locations
High Power Factor Electronic Ballast (Min. P.F. 99%), PL-T Lamps.
Class I, Division 2, Groups A, B, C, D
Class I, Zone 2, AEx nA nR IIC (Z2)
Class I, Zone 2, Ex nR IIC (Z) V

Class II, Division 1 and 2, Groups E, F, G
Class III
Simultaneous Exposure (Class I, Division 2/
Class II, Division 1)

Lamp
Watts

Fixtures Outside Type (Salt Water)
Type 4X
IP66

Catalog Numbers ➋➌

Hub
Size
(Inches)

With Globe
➊➍

3/4

MLCF262G2N

With Type V
8” Glass Refractor ➊➍➎

With Type V
Polymeric Refractor ➏

Ceiling — Five Hubs, Four Close-Up Plugs
1 x 26 W
1 x 32 W
1 x 42 W
2 x 26 W
1 x 57 W
2 x 32 W
Shown with Polymeric Refractor

2 x 42 W
2 x 57 W

MLCF262J5N

MLCF262P5N

1

MLCF263G2N

MLCF263J5N

MLCF263P5N

3/4

MLCF322G2N

MLCF322J5N

MLCF322P5N

1

MLCF323G2N

MLCF323J5N

MLCF323P5N

3/4

MLCF422G2N

MLCF422J5N

MLCF422P5N

1

MLCF423G2N

MLCF423J5N

MLCF423P5N

3/4

MLCF522G2N

MLCF522J5N

MLCF522P5N

1
3/4
1
3/4

MLCF523G2N

MLCF523J5N

MLCF523P5N

MLCF572G4N V

MLCF572J5N V

MLCF572P5N V

MLCF573G4N V

MLCF573J5N V

MLCF573P5N V

MLCF642G2N

MLCF642J5N

MLCF642P5N

1

MLCF643G2N

MLCF643J5N

MLCF643P5N

3/4

MLCF842G2N

MLCF842J5N

MLCF842P5N

MLCF843J5N

MLCF843P5N

MLCF1142G4N V

MLCF1142J5N V

MLCF1142P5N V

1

MLCF1143G4N V

MLCF1143J5N V

MLCF1143P5N V

3/4

MLWF262G2N

MLWF262J5N

MLWF262P5N

1

MLWF263G2N

MLWF263J5N

MLWF263P5N

3/4

MLWF322G2N

MLWF322J5N

MLWF322P5N

1

Wall Bracket — Five Hubs, Four Close-Up Plugs
1 x 26 W
1 x 32 W

2 x 26 W
1 x 57 W
2 x 32 W
Shown with 8” Glass Refractor

2 x 42 W
2 x 57 W

MLWF323G2N

MLWF323J5N

MLWF323P5N

MLWF422G2N

MLWF422J5N

MLWF422P5N

1

MLWF423G2N

MLWF423J5N

MLWF423P5N

3/4

MLWF522G2N

MLWF522J5N

MLWF522P5N

1

MLWF523G2N

MLWF523J5N

MLWF523P5N

3/4

MLWF572G4N V

MLWF572J5N V

MLWF572P5N V

1

MLWF573G4N V

MLWF573J5N V

MLWF573P5N V

3/4

MLWF642G2N

MLWF642J5N

MLWF642P5N

1

MLWF643G2N

MLWF643J5N

MLWF643P5N

3/4

MLWF842G2N

MLWF842J5N

MLWF842P5N

1

MLWF843G2N

MLWF843J5N

MLWF843P5N

3/4

MLWF1142G4N V

MLWF1142J5N V

MLWF1142P5N V

1

MLWF1143G4N V

MLWF1143J5N V

MLWF1143P5N V

➊ For fixtures with guard, substitute G for N before adding voltage suffix.
➋ Add voltage suffix -BU for 120 through 277 V, 50/60 Hz and 125 Vdc. Add voltage suffix -A5 for 347 V, 60 Hz.
➌ Add L after voltage suffix to include lamp.
➍ Add Z2 suffix for factory-sealed non-sparking/restricted breathing protection (Aex nA nR).
➎ To order fixture with NEMA Type I or III glass refractor, change J5 to J1 or J3 respectively.
➏ To order fixture with NEMA Type II, III, or IV polymeric refractor, change P5 to P2, P3 or P4 respectively. Polymeric refractor fixtures are UL Listed and CSA
Certified for Class II, Division 1 and 2, Groups F and G; Class III; Marine Outdoor Salt Water (UL1598A); NEMA 4X and CSA Type 4X.
V CSA Certification only.
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

1061

Lighting: Enclosed and Gasketed — Area — Fluorescent

1 x 42 W

1
3/4

Lighting

MLCF843G2N

3/4

Mercmaster™ III Low Profile Compact Fluorescent Luminaire Accessories
Enclosed and Gasketed. For Hazardous and Wet Locations

Compact Fluorescent listed for simultaneous exposure to combustible dusts and flammable gases or vapors.
Class I, Division 2, Groups A, B, C, D
Class I, Zone 2, AEx nA nR IIC (Z2)
Class I, Zone 2, Ex nR IIC (Z) V

Class II, Division 1 and 2, Groups E, F, G
Class III
Simultaneous Exposure (Class I, Division 2/
Class II, Division 1)

Description

Fixtures Outside Type (Salt Water)
Type 4X
IP66

Hub Size (Inches)

Catalog Number

Pendant
One Hub,
Rigid or Flexible Mounting

3/4

KPA-75

1

KPA-100

Five Hubs,
Four Close-Up Plugs

3/4

KPCH-75

1

KPCH-100

Five Hubs,
Four Close-Up Plugs

3/4

KPC-75

1

KPC-100

Five Hubs,
Four Close-Up Plugs

3/4

KPWB-75

1

KPWB-100

Pendant Cone

Ceiling

Lighting

Wall

25° Stanchion
One Hub

1-1/4

KPS-125

1-1/2

KPS-150

1-1/4

KPST-125

1-1/2

KPST-150

Lighting: Enclosed and Gasketed — Area — Fluorescent

90° Stanchion
One Hub

Ballast Bodies
Catalog Numbers
Lamp
Wattage

For Glass Globe or
Polymeric Refractor ➊➋

For Glass
Refractor ➋

1 x 26 W

MLBG26FBU

MLBR26FBU

1 x 32 W

MLBG32FBU

MLBR32FBU

1 x 42 W

MLBG42FBU

MLBR42FBU

2 x 26 W

MLBG52FBU
—

MLBR52FBU

1 x 57 W
2 x 32 W
2 x 42 W
2 x 57 W

MLBG64FBU
MLBG84FBU
—

MLBR64FBU
MLBR84FBU

Compact PL-T Fluorescent — 120 V to 277 V, 50/60 Hz and 125 Vdc

Ballast Body for Glass Globe
or Polymeric Refractor ➊

Ballast Body for
Glass Refractor

MLBR57F V

MLBR114F V

➊ Polymeric refractor not listed for Class I, Zone 2 areas.
➋ Add voltage suffix -BU for 120 through 277 V, 50/60 Hz and 125 Vdc. Add voltage suffix -A5 for 347 V, 60 Hz.
V CSA Certification only.

1062

Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

Mercmaster™ III Low Profile Compact Fluorescent Luminaire Accessories
Enclosed and Gasketed. For Hazardous and Wet Locations

Compact Fluorescent listed for simultaneous exposure to combustible dusts and flammable gases or vapors.

Item

Description

Catalog Number ➌

White Polyester Reflectors – Furnished with stainless steel screws
For Globe Fixtures
Standard Dome

KR2-ST

30° Angle

KR2-AN

Standard Dome
For Glass Refractor Fixtures ➊
Standard Dome

CMR-4ST ➋

30° Angle

CMR-4AN ➋

30° Angle Dome
Prismatic Glass Globes — Heat-Resistant ➌
Clear

VPGL-2HR

Amber ➍

VPGL-2AM

Blue ➍

VPGL-2BL

Green ➍

VPGL-2GR

Red ➍

VPGL-2RE

Clear — 57/114 Watt V

VPGL-4HR
Lighting

Closed Prismatic Glass Refractors — All Heat-Resistant ➌
NEMA Type I

LPG-R1

NEMA Type III

LPG-R3

NEMA Type V

LPG-R5

NEMA Type II

LPRF-2CP

NEMA Type III

LPRF-3CP

NEMA Type IV

LPRF-4CP

NEMA Type V

LPRF-5CP

Globe Guard

KGU2

Glass Refractor Guard  

KRG2

Globe Guard — 57/114 W V

KPGU400

Lighting: Enclosed and Gasketed — Area — Fluorescent

Closed Prismatic Polymeric Refractors — Not Listed for Class I, Zone 2 Areas

Guards

Globe Guard

Glass Refractor Guard

Globe Guard for 57 W Only
➊ Fixtures with refractors are not UL Listed when used with reflectors.
➋ Standard dome reflectors may interfere with bottom conduit entry if used with KPST and KPWB mounting hoods.
➌ Silicone or Teflon V coated globes are available. Contact your local sales representative.
➍ Non hazardous rated globes for special applications.
V CSA Certification only.
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

1063

Mercmaster™ III Low Profile Compact Fluorescent Luminaire Accessories
Enclosed and Gasketed. For Hazardous and Wet Locations

Compact Fluorescent listed for simultaneous exposure to combustible dusts and flammable gases or vapors.

Item

Description

Catalog Number

Replacement Optic Gaskets — Silicone rubber
Globe and Polymeric Refractor Gasket

VPGL-GK

Glass Refractor Gasket

KRF-GK

Replacement Lamp
Mercmaster III Low Profile Compact Fluorescent
Lamp Type

Lamp Base

Wattage

PL-T

GX24q-3

26

Catalog Number
PLT26

PL-T

GX24q-3

32

PLT32

PL-T

GX24q-4

42

PLT42

PL-T

GX24q-5

57

PLT57 V

Replacement Socket
For 26 W, 32 W and 42 W PLT Lamps listed above

PLT32RS

For 57 W PLT Lamp

PLT57RS V

Epoxy enameled steel – 6”/152.4 mm high red lettering

CJEXRN

Lighting

Three-Way Exit Sign ➊

Mounts to Globe Ballast Housing in place of guard.

Lighting: Enclosed and Gasketed — Area — Fluorescent

Single Sided Exit Sign ➊
Epoxy enameled steel – 6”/152.4 mm high red lettering

AEXR-15R

Mounts to Globe Ballast Housing in place of guard

Retrofit Pendant Mounting Adapter
Permits use of Mercmaster III pendant hood 	
with 3/4” hub on existing V-51 mounting hood

LPAD-1

Fuse Kit ➋
MLF2

2-Amp time delay fuse

➊ Consult your local sales representative for classified area suitability. Not listed for Zone 2 areas.
➋ Canadian Electrical Code does NOT allow fusing in hazardous locations V.
V CSA Certification only.

1064

Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

Mercmaster™ III Low Profile Compact Fluorescent Luminaire Electrical Specifications
Enclosed and Gasketed. For Hazardous and Wet Locations

Compact Fluorescent listed for simultaneous exposure to combustible dusts and flammable gases or vapors.
Class I, Division 2, Groups A, B, C, D
Class I, Zone 2, AEx nA nR IIC (Z2)
Class I, Zone 2, Ex nR IIC (Z) V

Class II, Division 1 and 2, Groups E, F, G
Class III
Simultaneous Exposure (Class I, Division 2/
Class II, Division 1)

Line Voltage

Fixtures Outside Type (Salt Water)
Type 4X
IP66

Total Watts

Electronic
Electronic
Electronic

.250
.110
.080

28
28
27

Electronic
Electronic
Electronic

.300
.130
.150

36
36
36

Electronic
Electronic
Electronic

.410
.180
.140

48
48
43

Electronic
Electronic
Electronic

.460
.220
.170

56
56
54

Electronic
Electronic
Electronic

.480
.210
.180

58
57
61

Electronic
Electronic
Electronic

.580
.260
.190

69
69
66

Electronic
Electronic
Electronic

.760
.320
.280

91
91
86

Electronic
Electronic
Electronic

.960
.420
.360

116
114
122

Lighting: Enclosed and Gasketed — Area — Fluorescent

Starting and Operating Amps

Lighting

Type of Ballast

26 Watt PL-T Fluorescent
120
277
347
32 Watt PL-T Fluorescent
120
277
347
42 Watt PL-T Fluorescent
120
277
347
52 Watt PL-T Fluorescent
120
277
347
57 Watt PL-T Fluorescent V
120
277
347
64 Watt PL-T Fluorescent
120
277
347
84 Watt PL-T Fluorescent
120
277
347
114 Watt PL-T Fluorescent V
120
277
347

Fuse catalog number: MLF2 (1 required for 120 V or 277 V) – 2-Amp fuse, time delay.
Minimum starting temperature: 0 °F/-18 °C

Energy Efficiency and Lamp Life Comparison
Lamp Type

Watts

Lumens

Lumen Output Comparison
Rated Average
Life (Hours)

Incandescent

100

1750

750

Incandescent

150

2880

750

Incandescent

200 (PS-25, PS-30)

3710

750

Incandescent

200 (A-23)

4010

750

PL-T Fluorescent

26

1800

10,000

PL-T Fluorescent

32

2400

10,000

PL-T Fluorescent

42

3200

10,000

PL-T Fluorescent

52

3600

10,000

PL-T Fluorescent

57 V

4300

12,000

PL-T Fluorescent

64

4800

10,000

PL-T Fluorescent

84

6400

10,000

PL-T Fluorescent

114 V

8600

12,000

V CSA Certification only.
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

Light Output as Function of Temperature

Relative
Light
Output %
PL-T
(Amalgam)
Quad --Degrees F

High lumen output of the amalgam technology lamp vs. the
reduced light output at variable temperatures from a typical
compact fluorescent lamp.

1065

Mercmaster™ III Low Profile Compact Fluorescent Luminaire Dimensions
Enclosed and Gasketed. For Hazardous and Wet Locations

Compact Fluorescent listed for simultaneous exposure to combustible dusts and flammable gases or vapors.

Dimensions
Pendant
12.06"/
306.3 mm

Pendant Cone
1.17"/
29.7 mm

Ceiling

25 Stanchion

13.62"/
346.9 mm
12.06"/
306.3 mm

12.06"/
306.3 mm

/
27”
15. .9 mm
387

5.59"/
142.0 mm

0”/
2.0 mm
8
50.

5”/
9.2 0 mm
5.
23

1.75"/
44.5 mm

/
03”
12. .6 mm
305

Wall Mount
17.00"/
431.8 mm

t
Se w
re
Sc

10.93”/
277.6 mm

25°

12.03”/
305.6 mm

9”/
7.5 8 mm
.
192

Polyester Reflector
17.23”/
437.6 mm

5.90"/
149.9 mm

9.79”/
248.7 mm

Globe or Polymeric
Refractor Ballast Housing

8" Glass Refractor
Ballast Housing
13.38"/
339.9 mm

13.38"/
339.9 mm

12.03”/
305.6 mm

Lighting

3.04"/
77.2 mm
5.50"/
139.7 mm
11.12"/
282.4 mm

18.70"/
475.0 mm

3.04"/
77.2 mm

2.48"/
63.0 mm

10.17"/
258.3 mm
"/
.06 m
17 .3 m
3
43

7.75"/
196.9 mm
11.12"/
282.4 mm

Globe and Refractors
5.50"/
139.7 mm

Lighting: Enclosed and Gasketed — Area — Fluorescent

5.50"/
139.7 mm

8.00"/
203.2 mm

4.50"/
114.3 mm

Aluminum Guards
7.94"/
201.6 mm

7.75"/
196.9 mm

7.25"/
184.2 mm

10.75"/
237.1 mm

12.38"/
314.5 mm

2.75"/
69.9 mm

6.75"/
171.5mm

11.00"/
279.4 mm

8.50"/
215.9 mm

5.88"/
149.4 mm

7.50"/
190.5 mm

8.88"/
225.6 mm

Accessory Weights ➊
Ballast Housings and
Mounting Hoods
Pendant
Pendant Cone
Ceiling
Wall Mount
25° Stanchion
90° Stanchion
Globe/Polymeric Refractor Housing
Glass Refractor Housing

Wt. Lbs/Kgs
2.25/1.0
2.50/1.1
3.00/1.4
4.00/1.8
3.25/1.5
3.75/1.7
5.60/2.5
6.50/2.9

Refractors, Globe,
Guards and Reflectors
8” Glass Refractor
Glass Globe
Glass Globe — 57/114 W V
Polymeric Refractor ➋
Glass Refractor Guard
Globe Guard
Globe Guard — 57/114 W V
Standard Dome
30° Angle
Exit Sign ➋

Wt. Lbs/Kgs
5.25/2.4
3.75/1.7
8.35/ 3.8
2.43/1.1
1.00/0.5
1.00/0.5
2.00/0.9
2.50/1.1
2.50/1.1
5.00/2.3

➊ Weights are approximate.
➋ Not listed for Class I, Zone 2 areas.
V CSA Certification only.

1066

Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

EFDB™ Series Factory-Sealed Photocontrol
Explosionproof, Dust-Ignitionproof
For use with Threaded Metal Conduit.
Explosionproof Remote
Photocontrol – Single Gang
Class I, Groups B, C, D
Class II, Groups, E, F, G
Class III

Applications
•	 Factory-sealed control stations
confine arcing of device within 	
the enclosure, preventing ignition 	
of atmospheres.
•	 Used in classified areas where
flammable vapors, gases or highly
combustible dusts are present.
•	 For installation in chemical and
petrochemical plants, refineries and
other process industries, or where
corrosive elements are present.

Features

Voltage

Max
Current (A)

Max
VA 

1/2

120

8.3

1000

EFDB150PC120

EFDCB150PC120

3/4

120

8.3

1000

EFDB175PC120

EFDCB175PC120

1

120

8.3

1000

EFDB110PC120

EFDCB110PC120

Replacement Parts for Remote Photocontrol
Catalog Number
Complete Cover
Photocontrol
Assembly
Only

Voltage

Current (A)

Max
VA

120

8.3

1000

EFKB-PC120

PC120X

208-277

3.5

1000

EFKB-PC277

PC277X

EFDB Single Gang
5/16 Dia. (2) Mtg. Holes
12-24 x 1
(4) Screws

A
B

4.63”/
117.6 mm

Lighting

•	 Finish is an epoxy powder coat for
enhanced corrosion resistance.
•	 Corrosion-resistant stainless steel
hex-head captive screws hold cover
to body.
•	 Factory-sealed enclosure eliminates
need for adding sealing fittings and
compound at each conduit entrance
(for Groups C & D applications).
•	 Accurately tapped, tapered 	
hubs for tight, rigid joints and 	
ground continuity.
•	 Smooth, rounded integral 	
bushing in each hub protects
conductor insulation.

Catalog Number ➋
Dead End 
Feed Through

Hub Size
(Inches)

5.41”/
137.4 mm

Lighting: Enclosed and Gasketed — Area — Fluorescent

C

2.31”/
58.7 mm
3.00”/
76.2 mm

4.81”/
122.2 mm

Dimensions in Inches
B

Hub Size
(Inches)

A

1/2 & 3/4

5.38

6.13

.78

1

5.50

6.31

.94

C

Turn On 1 to 3 footcandles; Turn On/Turn Off ratio: 1:3, Temperature range: -30 °F through 140 °F.
For Class I, Group B, external seals must be installed at each conduit entrance.
  For 208-277 volt rating, change 120 suffix to 277; current ratings become 3.5 A.
➋ Standard catalog number represents malleable iron body with aluminum cover. For aluminum body, add suffix -A.
V CSA Certification only.

Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

1067

Mercmaster™ III Low Profile Compact Fluorescent Luminaire Photometric Data
Enclosed and Gasketed. For Hazardous and Wet Locations

Compact Fluorescent listed for simultaneous exposure to combustible dusts and flammable gases or vapors.
* Photometric data is based on a fixture with
a 32 W compact fluorescent PL-T lamp (2,400
lumens).

Lighting: Enclosed and Gasketed — Area — Fluorescent

Lighting

Zone

Lumens

0-10

10.23

10-20

34.38

Total Luminaire Efficiency = 86.1%
CIE Type – Semi-Direct
Spacing
Criteria

Plane

20-30

64.27

30-40

105.64

0-180

2.80

40-50

151.34

90-270

2.68

50-60

194.61

Diagonal

2.50

60-70

224.08

70-80

243.06

80-90

248.58

90-100
100-110
110-120
120-130
130-140
140-150
150-160
160-170
170-180

241.28
220.55
182.81
109.74
33.74
1.67
0.14
0.00
0.00

Zone

Lumens

Zonal Lumen Summary
Zone
0-30
0-40
0-60
0-90
90-120
90-130
90-150
90-180
180-0

Lumens % Lamp % Fixture
108.88
4.5
5.3
214.52
8.9
10.4
560.47 23.4
27.1
1276.18 53.2
61.8
644.64 26.9
31.2
754.38 31.4
36.5
789.80 32.9
36.5
789.94 32.9
38.2
2066.12 86.1
100.0

10-20

105.58

20-30

178.09

30-40

242.36

0-180

1.68

40-50

291.93

90-270

1.64

50-60

323.02

Diagonal

1.74

60-70

314.54

70-80

216.11

80-90

76.59

Zone

Lumens

CIE Type – Direct
Spacing
Criteria

Plane

Zonal Lumen Summary
Zone
0-30
0-40
0-60
0-90
90-120
90-130
90-150
90-180
180-0

Lumens % Lamp % Fixture
318.12 13.3
17.8
560.48 23.4
31.4
1175.44 49.0
65.8
1782.68 74.3
99.8
3.72
0.2
0.2
3.72
0.2
0.2
3.72
0.2
0.2
3.72
0.2
0.2
1786.40 74.4
100.0

10-20

86.63

20-30

147.04

30-40

206.00

0-180

2.20

40-50

241.56

90-270

1.76

50-60

246.42

Diagonal

1.72

60-70

226.09

70-80

191.43

80-90

143.57

1068

80

70

50

30

10

0

0 95 95 95 95 89 89 89 89 77 77 77 67 67 67 58 58 58 53
1 81 75 70 65 75 70 65 61 60 56 53 51 48 45 43 40 38 34
2
3
4
5
6
7
8
9
10

72
64
58
53
48
45
41
38
36

63
53
46
41
36
32
29
26
24

55
45
38
32
28
24
21
19
17

49
38
31
26
22
18
16
14
12

66
59
53
49
44
41
38
35
33

58
49
43
38
33
30
27
24
22

51
42
35
30
26
22
20
18
16

46
36
29
24
20
17
15
13
11

50
42
36
32
28
25
23
21
19

44
36
30
26
22
19
17
15
14

40
31
25
21
17
15
13
11
10

42
35
30
27
24
21
19
18
16

37
30
25
21
19
16
14
13
12

34
26
21
17
15
12
11
9
8

34
29
25
22
19
18
16
15
13

31
25
21
18
15
13
12
11
10

28
22
17
14
12
10
9
8
7

24
18
14
11
9
8
7
6
5

REPORT NUMBER: MLF32ST
Lamps: One 32 W lamp with Standard Dome Reflector *
Coefficients of Utilization - Zonal Cavity Method
Effective Floor Cavity Reflectance 0.20
% Ceiling Rcc

80

70

50

30

10

0

0 89 89 89 89 86 86 86 86 83 83 83 79 79 79 76 76 76 74
1 79 75 71 67 77 73 69 66 70 67 64 66 64 62 64 62 60 58
2
3
4
5
6
7
8
9
10

70
63
57
52
48
44
41
38
36

63
54
47
41
37
33
30
27
25

57
47
40
34
29
26
23
21
19

52
41
34
28
24
21
18
16
14

68
61
55
50
46
43
40
37
35

62
53
46
40
36
32
29
27
25

56
46
39
33
29
26
23
20
18

51
41
34
28
24
21
18
16
14

59
50
44
39
35
31
28
26
24

54
45
38
33
28
25
22
20
18

50
40
33
28
24
21
18
16
14

56
48
42
37
33
30
27
25
23

52
43
37
32
28
24
22
20
18

49
39
33
27
23
20
18
16
14

54
46
40
36
32
29
26
24
22

51
42
36
31
27
24
21
19
18

48
39
32
27
23
20
18
16
14

46
37
30
25
21
19
16
14
13

Total Luminaire Efficiency = 68.5%

27.92

85.71
34.86
6.37
0.80
0.00
0.00
0.00
0.00
0.00

Effective Floor Cavity Reflectance 0.20
% Ceiling Rcc

% Walls Rw 70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0

0-10

90-100
100-110
110-120
120-130
130-140
140-150
150-160
160-170
170-180

Coefficients of Utilization - Zonal Cavity Method

Total Luminaire Efficiency = 74.4%

34.45

3.47
0.25
0.00
0.00
0.00
0.00
0.00
0.00
0.00

REPORT NUMBER: MLF32G
Lamps: One 32 W lamp with Globe only *

% Walls Rw 70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0

0-10

90-100
100-110
110-120
120-130
130-140
140-150
150-160
160-170
170-180

For candlepower values of fixtures with a 26
W PL-T lamp (1,800 lumens), multiply by 0.75.
For candlepower values of fixtures with a 42 W
PL-T lamp (3,200 lumens), multiply by 1.34.

CIE Type – Direct
Spacing
Criteria

Plane

REPORT NUMBER: MLF32AN
Lamps: One 32 W lamp with 30° Angle Dome Reflector *
Coefficients of Utilization - Zonal Cavity Method
Effective Floor Cavity Reflectance 0.20
% Ceiling Rcc

80

70

50

30

10

0

% Walls Rw 70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0
Zonal Lumen Summary
Zone
0-30
0-40
0-60
0-90
90-120
90-130
90-150
90-180
180-0

Lumens % Lamp % Fixture
261.58 10.9
15.9
467.59 19.5
28.4
955.56 39.8
58.1
1516.66 63.2
92.2
126.94
5.3
7.7
127.74
5.3
7.8
127.74
5.3
7.8
127.74
5.3
7.8
1644.40 68.5
100.0

0 80 80 80 80 78 78 78 78 73 73 73 69 69 69 65 65 65 63
1 71 66 62 59 68 64 60 57 60 57 54 56 54 52 53 51 49 47
2
3
4
5
6
7
8
9
10

63
57
51
47
43
40
37
34
32

56
48
42
37
33
30
27
25
22

50
42
35
30
26
23
21
18
17

45
36
30
25
21
19
16
14
13

61
54
49
45
41
38
35
33
31

54
47
41
36
32
29
26
24
22

49
41
34
30
26
23
20
18
16

44
36
29
25
21
18
16
14
13

51
44
38
34
30
27
25
23
21

46
39
33
28
25
22
19
17
16

43
34
28
24
20
18
16
14
12

48
41
36
32
29
26
23
22
20

44
37
31
27
24
21
19
17
15

41
33
27
23
20
17
15
14
12

45
39
34
30
27
24
22
20
19

42
35
30
26
23
20
18
16
15

39
32
26
22
19
17
15
13
12

37
30
25
21
18
15
13
12
10

Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

Mercmaster™ III Low Profile Compact Fluorescent Luminaire Photometric Data
Enclosed and Gasketed. For Hazardous and Wet Locations

Compact Fluorescent listed for simultaneous exposure to combustible dusts and flammable gases or vapors.
* Photometric data is based on a fixture with
a 32 W compact fluorescent PL-T lamp (2,400
lumens).

Zone

Lumens

Total Luminaire Efficiency = 80.9%

0-10

18.85

10-20

63.99

20-30

125.20

30-40

205.98

0-180

2.24

40-50

294.73

90-270

2.64

50-60

370.74

Diagonal

2.74

60-70

425.25

70-80

457.39

80-90
90-100
100-110
110-120
120-130
130-140
140-150
150-160
160-170
170-180

463.07
445.19
402.45
328.71
203.51
69.29
8.05
0.13
0.00
0.00

Zone

Lumens

CIE Type – Semi-Direct
Spacing
Criteria

Plane

Zonal Lumen Summary
Zone
0-30
0-40
0-60
0-90
90-120
90-130
90-150
90-180
180-0

Lumens % Lamp % Fixture
208.05
4.3
5.4
414.02
8.6
10.7
1079.50 22.5
27.8
2425.21 50.5
62.5
1176.35 24.5
30.3
1379.86 28.7
35.5
1457.21 30.4
35.5
1457.34 30.4
37.5
3882.55 80.9
100.0

193.68

20-30

332.52

30-40

456.54

0-180

1.62

40-50

551.40

90-270

1.66

50-60

602.56

Diagonal

1.84

60-70

573.69

70-80

386.39

CIE Type – Direct
Spacing
Criteria

Plane

80

70

50

30

10

0

0 89 89 89 89 83 83 83 83 73 73 73 63 63 63 55 55 55 51
1
2
3
4
5
6
7
8
9
10

76
68
61
55
50
46
42
39
36
34

71
59
50
44
38
34
30
27
25
22

66
52
42
35
30
26
23
20
18
16

61
46
36
29
24
20
17
15
13
11

71
62
56
50
46
42
39
36
33
31

66
55
47
40
35
31
28
25
23
21

61
48
40
33
28
24
21
19
17
15

57
43
34
27
23
19
16
14
12
11

57
47
40
34
30
27
24
22
20
18

53
42
34
28
24
21
18
16
14
13

50
37
29
24
19
16
14
12
11
9

48
40
33
29
25
23
20
18
17
15

45
36
29
24
20
18
15
14
12
11

43
32
25
20
17
14
12
10
9
8

41
33
28
24
21
19
17
15
14
13

38
30
24
20
17
15
13
11
10
9

36
27
21
17
14
11
10
8
7
6

32
23
18
14
11
9
8
6
5
5

REPORT NUMBER: MLF64ST
Lamps: Two 32 W lamps with Standard Dome Reflector *
Coefficients of Utilization - Zonal Cavity Method
Effective Floor Cavity Reflectance 0.20
% Ceiling Rcc

80

70

50

30

10

0

% Walls Rw 70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0
Zonal Lumen Summary
Lumens % Lamp % Fixture
589.15 12.3
17.9
1045.70 21.8
31.7
2199.66 45.8
66.7
3293.22 68.6
99.9
2.39
0.0
0.1
2.39
0.0
0.1
2.39
0.0
0.1
2.39
0.0
0.1
3295.61 68.7
100.0

0 82 82 82 82 80 80 80 80 76 76 76 73 73 73 70 70 70 69
1
2
3
4
5
6
7
8
9
10

73
65
59
53
48
44
41
38
35
33

69
58
50
44
38
34
31
28
25
23

65
53
44
37
31
27
24
21
19
17

62
48
38
31
26
22
19
17
15
13

71
63
57
51
47
43
40
37
34
32

67
57
49
43
38
33
30
27
25
23

64
52
43
36
31
27
24
21
19
17

61
48
38
31
26
22
19
17
15
13

64
55
47
41
36
32
29
26
24
22

62
50
42
35
30
26
23
21
19
17

59
46
37
31
26
22
19
17
15
13

62
52
45
39
35
31
28
25
23
21

59
49
40
34
29
26
23
20
18
17

57
45
37
30
25
22
19
17
15
13

59
50
43
38
33
30
27
24
22
21

57
47
39
33
29
25
22
20
18
16

56
44
36
30
25
22
19
16
15
13

54
43
34
28
24
20
17
15
13
12

Total Luminaire Efficiency = 62.8%

50.16

10-20

156.40

20-30

272.40

30-40

383.54

0-180

2.16

40-50

446.01

90-270

1.70

50-60

442.26

Diagonal

1.80

60-70

405.74

70-80

352.81

CIE Type – Direct
Spacing
Criteria

Plane

REPORT NUMBER: MLF64AN
Lamps: Two 32 W lamps with 30° Angle Dome Reflector *
Coefficients of Utilization - Zonal Cavity Method
Effective Floor Cavity Reflectance 0.20
% Ceiling Rcc

80

70

50

30

10

0

% Walls Rw 70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0
Zonal Lumen Summary
Zone
0-30
0-40
0-60
0-90
90-120
90-130
90-150
90-180
180-0

Lumens % Lamp % Fixture
478.96 10.0
15.9
862.50 18.0
28.6
1750.77 36.5
58.1
2778.65 37.9
92.2
234.15
4.9
7.8
235.69
4.9
7.8
235.69
4.9
7.8
235.69
4.9
7.8
3014.34 62.8
100.0

Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

0 74 74 74 74 71 71 71 71 67 67 67 63 63 63 60 60 60 58
1
2
3
4
5
6
7
8
9
10

65
58
52
47
43
40
36
34
31
29

61
51
44
39
34
30
27
25
22
21

57
46
38
32
28
24
21
19
17
15

54
42
33
27
23
20
17
15
13
12

62
55
50
45
41
38
35
32
30
28

59
50
43
37
33
29
26
24
22
20

55
45
37
31
27
24
21
19
17
15

52
41
33
27
23
19
17
15
13
12

55
46
40
35
31
28
25
23
21
19

52
42
35
30
26
23
20
18
16
15

50
39
31
26
22
19
16
14
13
11

52
44
38
33
29
26
24
22
20
18

49
40
34
29
25
22
19
17
15
14

47
37
30
25
21
18
16
14
12
11

48
41
35
31
27
25
22
20
19
17

47
38
32
27
24
21
18
16
15
14

45
36
29
24
21
18
15
14
12
11

43
34
27
22
19
16
14
12
11
10

1069

Lighting: Enclosed and Gasketed — Area — Fluorescent

Zone
0-30
0-40
0-60
0-90
90-120
90-130
90-150
90-180
180-0

0-10

80-90
269.34
90-100 159.49
100-110 63.13
110-120 11.54
120-130
1.54
130-140
0.00
140-150
0.00
150-160
0.00
160-170
0.00
170-180
0.00

Effective Floor Cavity Reflectance 0.20
% Ceiling Rcc

Lighting

10-20

Lumens

Coefficients of Utilization - Zonal Cavity Method

Total Luminaire Efficiency = 68.7%

62.95

Zone

REPORT NUMBER: MLF64G
Lamps: Two 32 W lamps with Globe only *

% Walls Rw 70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0

0-10

80-90
133.48
90-100
2.39
100-110
0.00
110-120
0.00
120-130
0.00
130-140
0.00
140-150
0.00
150-160
0.00
160-170
0.00
170-180
0.00

For candlepower values of fixtures with a 26
W PL-T lamp (1,800 lumens), multiply by 0.75.
For candlepower values of fixtures with a 42 W
PL-T lamp (3,200 lumens), multiply by 1.34.

FV™ Series Nonmetallic Fluorescent Luminaires
For Hazardous and Adverse Locations
Class I, Division 2, Groups A, B, C, D
Class I, Zone 2, Group IIC
Class II Division 1, Groups E, F, G
Class II, Division 2, Groups F, G

Marine Type Electric Fixture
Outside Type (Salt Water) *
Type 4X
Wet Locations

Applications
•	 For use in hazardous locations defined by the NEC as Class I,
Division 2, Groups A, B, C and D; Class II, Division 2, Groups
F and G; Marine Outdoor Salt Water; UL1598A; Type 4X; and
Class I, Zone 2 II C.
•	 For use in locations where a high degree of corrosion resistance
is required.
•	 For indoor or outdoor use where protection against dirt, water
and moisture is necessary.
•	 Typical applications include oil refineries, petrochemical
facilities, pulp and paper mills, food processing plants,
warehouses, underground tunnels and general manufacturing
facilities.

Lighting

Features
•	 Stainless steel hubs (3/4”) provided as standard.
•	 Ballast options for nearly all U.S. and foreign voltage and
frequency combinations are available.
•	 Low operating costs provide more lumens per Watt than
incandescent fixtures.
•	 Impact-resistant polycarbonate lens is hinged to allow easy
access to lamp compartment.
•	 Corrosion-resistant fiberglass reinforced polyester housing.
•	 Actuator allows access to lamps and ballast compartment – 	
no tools required.
•	 Latch assembly and elastomer type gasket provide positive 	
seal from water ingress.
•	 Safety switch (supplied as standard) disconnects power to
lamps and ballast when lens is open.
•	 Reflector is hinged for easy single-handed entry to ballast
compartment.
•	 Actuator can be removed for tamper-resistant applications.

Compliancies and Certifications
•	 UL Standard: UL 1598, UL 844, UL 60079-0, UL 60079-15
•	 UL Listed: E10794
•	 CSA Standard: C22.2 No. 250, C22. 2 No. 137, CAN E60079-0,
CAN E60079-15
•	 cUL Listed: E10794

Lighting: Enclosed and Gasketed — Area — Fluorescent

Standard Materials
•	
•	
•	
•	
•	
•	
•	
•	

Housing: fiberglass reinforced polyester
Lens: polycarbonate
Gasket: elastomer
Hubs: stainless steel
Lampholders: polycarbonate
Internal reflector: highly reflective white polycarbonate
Fixed surface mount: (2) 14-gauge stainless steel
Adjustable wall mount: (2) copperfree (4/10 of 1% max.)
aluminum
•	 45° fixed wall mount: (2) 11-gauge (1/8”) stainless steel
•	 Chain ring bolt: set of 2 zinc plated steel (internal diameter .78”)

Options
•	
•	
•	
•	

Individually fused ballast. Add suffix -F.
Terminal block. Add suffix -T.
Emergency battery pack. Add suffix -EL.
Emergency light capability in moments of power interruption.
Luminaire automatically switches to emergency mode, keeping
one lamp illuminated for a minimum of 90 minutes. When AC
power is restored, battery automatically recharges in 24 hours.
Initial light output is 600-700 lumens.

* Does not apply to fixtures with fusing.

1070

Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

FV™ Series Nonmetallic Fluorescent Luminaires
For Hazardous and Adverse Locations
Class I, Division 2, Groups A, B, C, D
Class I, Zone 2, Group IIC
Class II Division 1, Groups E, F, G
Class II, Division 2, Groups F, G

Marine Type Electric Fixture
Outside Type (Salt Water) *
Type 4X
Wet Locations

Order using catalog numbering guide below or select catalog number from tables on following pages.
Catalog Numbering Guide For FV Series Nonmetallic Fluorescent Luminaires
FV
Series:
FV - FV Series	

P

2

32

Number of Lamps:
2 - 2 Lamps
3 - 3 Lamps (32 W only)
4 - 4 Lamps (40 W only,
F40BX)

Lamp Type:
P - "PL" Fluorescent (F40BX)
R - Rapid Start
H - High Output

BU

SO

Voltage ①:
347 - 347 V 60 Hz V
BU - 120-277 V 50/60 Hz ③

Wattage:
32 - 32 W (T8)
40 - 40 W (T12-RS, F40BX)
44 - 44 W (T-8-HO)
60 - 60 W (T-12-HO)

F
Options:
F - Fuse
T - Terminal Block (6 Point)
EL - Emergency Battery Pack ②

Ballast Type:
SS - Solid State (for 347 V T-12)

Lamp
Type

Hub Size
(Inches)

Overall Fixture Length
(Inches/Millimeters)

Volts

2

40

F40BX

3/4

31/787.4

120-277

2

40

F40BX

3/4

31/787.4

347

4

40

F40BX

3/4

55/1397

120-277

4

40

F40BX

3/4

55/1397

347

2

32

T8

3/4

55/1397

120-277

2

32

T8

3/4

55/1397

347

2

44

T8-HO

3/4

55/1397

120-277

2

44

T8-HO

3/4

55/1397

347

2

40

T12

3/4

55/1397

120-277

2

40

T12

3/4

55/1397

347

2

60

T12-HO

3/4

55/1397

120-277

2

60

T12-HO

3/4

55/1397

347

3

32

T8

3/4

55/1397

120-277

3

32

T8

3/4

55/1397

347

Catalog
Number ⑦
FVP240BU
FVP240-347 V
FVP440BU
FVP440-347 V
FVR232BU
FVR232-347S0 V
FVH244BU
FVH244-347S0 V
FVR240BU
FVR240-347SS V
FVH260BU
FVH260-347SS V
FVR332BU
FVR332-347S0 V

Note: BU ballasts are auto-sensing, solid state for any voltage between 120 and 277 V, 50 or 60 Hz.
* Does not apply to fixtures with fusing.
① Consult factory for availability of specific voltages.
② 4’ fixture only.
③ 32 W SS Octron and F40BX only.
V CSA Certification only.
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

1071

Lighting: Enclosed and Gasketed — Area — Fluorescent

Lamp
Watts

Lighting

Number of
Lamps ⑥

FV™ Series Nonmetallic Fluorescent Luminaires
For Hazardous and Adverse Locations
Class I, Division 2, Groups A, B, C, D
Class I, Zone 2, Group IIC
Class II Division 1, Groups E, F, G
Class II, Division 2, Groups F, G

Marine Type Electric Fixture
Outside Type (Salt Water) *
Type 4X
Wet Locations

Description

Catalog
Number

Standard Materials
14-gauge stainless steel

FVSM

Adjustable Wall Mount (set of 2)

Copperfree (4/10 of 1% max.) aluminum

FVWAM

Fixed 45°˚ Wall Mount (set of 2)

11-gauge (1/8”) stainless steel

FVWFM

Chain Mount (set of 2)

Zinc plated steel M8 ring bolts (chain not provided)

FVCM

Lighting

Surface Mount (set of 2)

Technical Data — Thermal Performance of FV Series Fixtures

For supply connection, use wire rated 167 °F/75 °C.

Lighting: Enclosed and Gasketed — Area — Fluorescent

Lamp

Min. Start
Temp ˚
(°C/°˚F)

Ambient
Temp.
(°C/°˚F)

“T”
Numbers

Quantity

Watt

Type

Lamp
Lumens

FVP240BU

2

40

F40BX

3300

-18/0

55/131

T4

FVP240-347 V

2

40

F40BX

3300

-18/0

55/131

T4

FVP440BU

4

40

F40BX

3300

-18/0

55/131

T4

FVP440-347 V

4

40

F40BX

3300

-18/0

55/131

T4

FVR232BU

2

32

T8-RS

2850

-18/0

40/104

T6

FVR232-347S0

2

32

T8-RS

2850

-18/0

40/104

T6

FVH244-BU

2

44

T8-HO

4050

-10/14

40/104

T6

FVH244-347S0 V

2

44

T8-HO

4050

-10/14

40/104

T6

FVR240BU

2

40

T12-RS

3050

10/50

40/104

T5

FVR240-347SS V

2

40

T12-HO

3050

10/50

40/104

T5

FVH260BU

2

60

T12-HO

4050

-28/-20

40/104

T4A

FVH260-347SS V

2

60

T12-HO

4050

-28/-20

40/104

T4A

FVR332BU

3

32

T8-RS

2850

-18/0

40/104

T6

Fixture

* Does not apply to fixtures with fusing.
V CSA Certification only.

1072

Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

FV™ Series Nonmetallic Fluorescent Luminaire Dimensions
For Hazardous and Adverse Locations

Dimensions
FV Series
A

0.6"/
15.24 mm

5.7"/
144.8 mm

8.6"/
218.4
mm
B

FVWFM

FVWAM

FVSM

FVCM
Ø 0.31"/
8.0 mm
Ø 0.78"/
19.8 mm

9.25”/
235.0 mm

0.31"/
7.87 mm

60° MAX.

0.20"/
5.08 mm

1.25"/
31.8 mm

0.20"/
5.08 mm

4.00”/
101.6 mm

3.56"/
90.4 mm
7.72"/
196.1 mm

0.31"/
7.87 mm

0.38”/
9.5 mm

Lighting: Enclosed and Gasketed — Area — Fluorescent

0.31"/
7.9 mm
Dia.

0.31"/
7.87 mm

25 1.0
.4 0"
m /
m

7.64"/
194.1 mm

Ø 0.31"/8.0 mm

Lighting

7.5”/
190.5 mm
9.5"/
241.3 mm

0.59"/
15.0 mm

10 4.
4. 13
9 "/
m
m

9.21”/
233.9 mm

60 2.3
.5 8"
m /
m
8
20 .
2
9. 5
6 "/
m
m
24 9.
1. 50
3 "/
m
m

23 0.9
.9 4"
m /
m

0.70"/
17.78 mm

0.25"/
6.3 mm Dia.

Mounting Centers and Overall Length
A

B

2 FT./0.6 M

15.80”/401.3 mm

31.00”/787.4 mm

4 FT./1.2 M

27.60"/701.0 mm

55.00”/1397.0 mm

Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

1073

FV™ Series Nonmetallic Fluorescent Luminaire Photometric Data
For Hazardous and Adverse Locations

Lighting: Enclosed and Gasketed — Area — Fluorescent

Lighting

CIE TYPE – DIRECT
PLANE: 0 DEG. 90 DEG.
SPACING CRITERIA:
1.2
1.5
CANDELA DISTRIBUTION

0
5
15
25
35
45
55
65
75
85
90

0.0
3152  
3139  
3030
2798  
2470  
2043  
1523
941
378  
49  
10  

45.0
3152
3138
3060
2910
2740
2517
2130
1656
1234
679
474

ZONAL
90.0 LUMENS
3152
3130
299
3036
868
3041 1351
2091 1720
2760 1897
2373 1827
1976 1553
1532 1163
901
649
694

CIE TYPE – DIRECT
PLANE: 0 DEG. 90 DEG.
SPACING CRITERIA:
1.2
1.5
CANDELA DISTRIBUTION

0
5
15
25
35
45
55
65
75
85
90

0.0
1101
1098
1056
976
856
710
528
328
132
14
4

45.0
1101
1098
1069
1026
985
928
830
681
567
340
252

ZONAL
90.0 LUMENS
1101
1097
104
1085
303
1093
477
1096
616
1075
703
986
709
849
636
757
530
499
332
397

CIE TYPE – DIRECT
PLANE: 0 DEG. 90 DEG.
SPACING CRITERIA:
1.2
1.4
CANDELA DISTRIBUTION

0
5 
15
25
35
45
55
65
75
85
90

0.0
1780
1767
1700
1574
1388
1150
860
53
214
21
7

1074

45.0
1780
1773
1732
1661
1554
1388
12001
6949
698
443
319

ZONAL
90.0 LUMENS
1780 169
1771 169
1757 490
1734 767
1652 1064
1556 1064
3671 038
1116 881
914 675
637 426
491

50
.95
.80
.69
.60
.53
.47
.43
.39
.36
.33
.30

10
30
.95
.78
.65
.55
.48
.42
.37
.33
.30
.27
.24

10
.95
.75
.61
.51
.43  
.37
.32
.28
.25
.23
.20

FVP 440, Four 40 W PL Lamps • Total Luminaire Efficiency = 85.8%
% Floors Rfc
20
% Ceiling Rcc
80
70
50
30
% Walls Rw 70 50 30 10 70 50 30 10
50 30 10
50 30 10
0 1.02 1.02 1.02 1.02 1.00 1.00 1.00 1.00 .95 .95    .95 .91 .91 .91
1 .99 .93 .89 .84 .96 .91 .87 .83 .87 .83 .80 .83 .80 .78
2 .89 .80 .73 .67 .86 .78 .72 .66 .75 .69 .64 .72 .67 .63
3 .74 .64 .56 .50 .72 .63 .56 .50 .60 .54 .49 .58 .52 .48
4 .68 .56 .48 .42 .66 .55 .48 .42 .53 .46 .41 .51 .45 .40
5 .62 .50 .42 .36 .60 .49 .41 .35 .47 .40 .35 .46 .39 .35
6 .57 .45 .37 .31 .55 .44 .36 .31 .42 .36 .30 .41 .35 .30
7 .53 .41 .33 .27 .51 .40 .32 .27 .38 .32 .27 .37 .31 .26
8 .49 .37 .29 .24 .48 .36 .29 .24 .35 .28 .24 .34 .28 .24
9 .46 .34 .26 .21 .45 .33 .26 .21 .32 .26 .21 .31 .25 .21
10 .43 .31 .24 .19 .42 .31 .24 .19 .30 .23 .19 .29 .23 .19

50
.88
.80
.69
.55
.49
.44
.40
.36
.33
.30
.28

10
30
.88
.78
.65
.51
.44
.39
.34
.30
.27
.25
.23

0
10
0
.88 .86
.75 .73
.61 .59
.47 .45
.40    .38
.44 .32
.30 .28
.26 .24
.23 .22
.21 .19
.19 1.75

70
.92
.81
.73
.65
.60
.55
.50
.47
.43
.40
.38

FVR 232, Two T8 32 W Lamps* • Total Luminaire Efficiency = 77.4%
20
80
70
50
30
50 30 10 70 50 30 10
50 30 10
50 30 10
.92 .92 .92 .90 .90 .90 .90 .86 .86 .86   .82 .82 .82
.77 .72 .68 .79 .75 .71 .67 .71 .68 .65 .68 .66 .63
.65 .59 .53 .71 .64 .58 .53 .61 .56 .51 .58 .54 .50
.56 .49 .44 .63 .55 .49 .43 .53 .47 .43 .51 .46 .42
.49 .42 .36 .58 .48 .41 .35 .46 .40 .35 .44 .39 .34
.44 .37 .31 .53 .43 .36 .31 .41 .35 .31 .40 .34 .30
.39 .31 .26 .49 .38 .31 .26 .35 .30 .26 .35 .30 .25
.35 .28 .23 .45 .35 .28 .23 .33 .27 .22 .32 .26 .22
.32 .25 .20 .42 .31 .25 .20 .30 .24 .20 .29 .24 .20
.29 .22 .18 .39 .29 .22 .18 .28 .22 .18 .27 .21 .18
.27 .20 .16 .37 .26 .20 .16 .26 .20 .16 .25 .20 .16

50
.79
.65
.56
.49
.42
.38
.34
.31
.28
.26
.24

10
30
.79
.63
.52
.45
.38
.34
.29
.26
.23
.21
.19

10
.79
.61
.49
.41
.34
.30
.25
.22
.19
.17
.16

0
0
.77
.59
.47
.39
.32
.28
.23
.20
.18
.16
.14

70
.90
.80
.72
.65
.60
.55
.50
.46
.43
.40
.38

FVR 332, Three T8 32 W Lamps • Total Luminaire Efficiency = 75.7%
20
80
70
50
30
50 30 10 70 50 30 10
50 30 10
50 30 10
.90 .90 .90 .88 .88 .88 .88 .84 .84 .84 .81 .81 .81
.76 .72 .68 .78 .74 .70 .67 .71 .68 .65 .68 .65 .63
.65 .59 .54 .70 .63 .58 .53 .61 .56 .52 .58 .54 .51
.56 .49 .44 .63 .55 .49 .43 .53 .47 .43 .51 .46 .42
.50 .42 .37 .58 .48 .42 .36 .47 .41 .36 .45 .39 .35
.44 .37 .31 .53 .43 .36 .31 .41 .35 .31 .40 .34 .30
.39 .32 .27 .49 .39 .32 .27 .37 .31 .27 .36 .30 .26
.36 .29 .24 .45 .35 .28 .23 .34 .28 .23 .33 .27 .23
.32 .26 .21 .42 .32 .25 .21 .31 .25 .21 .30 .24 .21
.30 .23 .19 .39 .29 .23 .19 .28 .23 .19 .27 .22 .18
.27 .21 .17 .37 .27 .21 .17 .26 .21 .17 .25 .20 .17

50
.77
.65
.56
.49
.43
.38
.35
.32
.29
.27
.25

10
30
.77
.63
.52
.45
.38
.34
.30
.27
.24
.22
.20

10
.77
.61
.50
.41
.35
.30
.26
.23
.20
.18
.17

0
0
.76
.59
.48
.39
.33
.28
.24
.21
.19
.17
.15

Room Cavity Ratio

ZONAL
90.0 LUMENS
1705
1687
161
1688
468
1660
731
1623
932
1516 1027
1292
992
1065
836
821
619
497
351
399

Room Cavity Ratio

45.0
1705
1698
1642
1581
1492
1361
1161
888
644
360
257

• Total Luminaire Efficiency = 92.7%
20
50
30
10
50 30 10
50 30 10
1.08 1.03 1.03 1.03 .99 .99 .99
.83 .87 .83 .80 .83 .80 .78
.66 .75 .69 .64 .72 .67 .63
.54 .65 .58 .53 .62 .57 .52
.44 .57 .50 .44 .55 .49 .44
.38 .51 .44 .38 .49 .43 .37
.33 .46 .38 .33 .44 .38 .33
.29 .42 .34 .29 .40 .34 .29
.26 38 .31 .25 .37 .30 .25
.23 .35 .28 .23 .34 .27 .23
.21 .32 .25 .21 .31 .25 .21

% Floors Rfc
% Ceiling Rcc
% Walls Rw
0
1
2
3
4
5
6
7
8
9
10

Room Cavity Ratio

0
5
15
25
35
45
55
65
75
85
90

0.0
1705
1701
1635
1513
1324
1085
806
490
197
32
12

FVP 240, Two 40 W PL Lamps
% Floors Rfc
% Ceiling Rcc
80
70
% Walls Rw 70 50 30 10 70 50 30
0 1.10 1.10 1.10 1.10 1.08 1.08 1.08
1 .99 .93 .89 .84 .96 .91 .87
2 .89 .80 .73 .67 .86 .78 .72
3 .80 .69 .61 .54 .78 .68 .60
4   .73 .61 .52 .45 .71 .60 .51
5 .67 .54 .45 .39 .65 .53 .45
6 .62 .49 .40 .33 .60 .48 .39
7 .57 .44 .35 .29 .55 .43 .35
8 .53 .40 .32 .26 .52 .39 .31
9 .50 .37 .29 .23 .48 .36 .28
10 .46 .34 .26 .21 .45 .33 .26

% Floors Rfc
% Ceiling Rcc
% Walls Rw
0
1
2
3
4
5
6
7
8
9
10

Room Cavity Ratio

CIE TYPE – DIRECT
PLANE: 0 DEG. 90 DEG.
SPACING CRITERIA:
1.2
1.5
CANDELA DISTRIBUTION

0
0
.93
.73
.59
.49
.41
.35
.30
.26
.23
.21
.19

Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

FR™ Enclosed and Gasketed; FZ™ and FD™ Hazardous Locations Luminaires

Nonmetallic Fluorescent

4 foot, 2 lamp fixtures. High-impact fiberglass reinforced polyester fixtures suitable for use in wet and damp locations.
FR Series
Wet Locations
IP65 when used with optional polycarbonate
lens

FZ Series
Class I, Division 2, Groups A, B, C, D
Class I, Zone 2, IIC
AEx nA IIC T5 IP65
Ex nA IIC T5 IP65

FD Series
Class I, Division 2, Groups A, B, C, D
Class I, Zone 2, IIC

Applications
•	 For use in locations where a high degree of corrosion
resistance is required.
•	 FR Series:
— For use in areas where high humidity or water vapor are 	
present
— Typical uses include meat- or food-processing plants, dairy
or drug plants, breweries, kitchens, chemical plants, car
washes, laundries and parking garages.
— Can be used indoors or outdoors in protected locations 	
(wet locations).
— Operates safely in 100 °F/38 °C ambient temperature areas.
•	 FZ and FD Series:
—	For use in hazardous locations defined by the NEC as
Class I, Division 2; and Class I, Zone 2.
—	For wet-location use where protection against dirt, water
and moisture is necessary.
— Typical applications include oil refineries, petrochemical
facilities, pulp and paper mills, food-processing plants,
warehouses, underground tunnels and general
manufacturing facilities.
•	 FZ Series is UL Listed for Class I, Division 2 and Zone 2.
•	 FD Series fixture is UL listed for Class I, Division 2.

Features

•	 Housing: fiberglass reinforced polyester
•	 Lens: polycarbonate or acrylic. (Fixture has IP65 rating with
polycarbonate lens.) Acrylic lens supplied as standard
•	 Latches: celcon
•	 Ceiling mounting bracket: stainless steel
•	 Adjustable wall mount: copperfree (4/10 of 1% max.) aluminum
•	 Fixed wall mount: stainless steel

Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

•	
•	
•	
•	

Chain mount: zinc plated steel
Gasket: non-thixotropic polyol
Hubs: zinc plated steel with neoprene o-ring
Lampholders: polycarbonate

Standard Finishes
•	 Housing: white color finish
•	 Celcon latches: white color finish
•	 Adjustable wall mount: epoxy powder coat

Options:
•	
•	
•	
•	

F - Fused
T - Terminal Blocks
P - Polycarbonate Lens for IP65 Rating
E - Emergency Battery Pack capability in moments of power
interruption. Luminiare automatically switches to emergency
mode, keeping one lamp illuminated for a minimum of 90
minutes. When AC power is restored, battery automatically
recharges in 24 hours. Initial light output is 600-700 lumens.

Compliancies and Certifications
•	
	
	
	
	
•	
	
	
	
	
•	
	
	
	
	

FR Series:
— UL Standard: UL 1598
— UL Listed: E187946
— CSA Standard: C22.2 No. 250
— cUL Listed: E187946
FZ Series:
— UL Standard: UL 1598, UL 844, UL 60079-0, UL 60079-15
— UL Listed: E10794
— CSA Standard: C22.2 No. 250, C22.2 No. 137, 	
CAN E60079-0, CAN E60079-15
— cUL Listed: E10794
FD Series:
— UL Standard: UL 1598, UL 844
— UL Listed: E10794
— CSA Standard: C22.2 No. 250, C22.2 No. 137
— cUL Listed: E10794

1075

Lighting: Enclosed and Gasketed — Area — Fluorescent

Standard Materials

Non-thixotropic polyol gasket is
bonded to housing. With plastic
latches closed, it forms a continuous, tight seal with lens. Keeps out
moisture, vapor and dirt. Allows fast,
easy fixture washing.

Lighting

•	 Fixtures are available with ballasts to support T12 and T8 	
lamps for nearly all U.S. and foreign voltage and frequency
combinations.
•	 Low operating costs provide more lumens per Watt than
incandescent fixtures.
•	 Housing is smooth, seamless, one-piece injection molded.
•	 Lens comes in high-impact polycarbonate plastic or impactresistant acrylic.
•	 Fixtures are washable, non-conductive and corrosion-resistant.
•	 Enclosure is rated at IP65 (using polycarbonate lens), dust-proof
and protected against water spray.
•	 A compressible, one-piece, non-thixotropic polyol gasket 	
is bonded to the housing around the entire perimeter. It 	
forms a continuous tight seal with the lens to keep out dirt,
vapor and moisture.
•	 Lens is securely clamped to fixture using six captive 	
corrosion-proof molded celcon tension latches. Lens is 	
impact-resistant acrylic to protect lamps against breakage, 	
and protect work area from broken lamp glass.
•	 Electrical components are mounted on a metallic wireway.
Reflector is supported by internal safety springs to simplify
installation and servicing.
•	 Optional fusing protects circuitry against occasional line voltage
spikes.
•	 FR Series fixtures are available with one or two watertight 1/2”
hubs for electrical-feed mounting or single-entry mounting.
•	 FZ fixtures are available with either 1/2” NPT or cable gland
entries.
— Cable glands are not available with FD series.

Illustrated Features

FR™ Enclosed and Gasketed; FZ™ and FD™ Hazardous Locations Luminaires
Nonmetallic Fluorescent

4 foot, 2 lamp fixtures. High-impact fiberglass reinforced polyester fixtures suitable for use in wet and damp locations.
FR Series
Wet Locations
IP65 when used with optional polycarbonate
lens

FZ Series
Class I, Division 2, Groups A, B, C, D
Class I, Zone 2, IIC
AEx nA IIC T5 IP65
Ex nA IIC T5 IP65

FD Series
Class I, Division 2, Groups A, B, C, D
Class I, Zone 2, IIC

Order using catalog numbering guide below or select catalog number from tables on following pages.
Catalog Numbering Guide For FR, FZ And FD Nonmetallic Fluorescent Lighting Fixtures
FZ

N1

C

2

Conduit/Cable
Entry:
N1 - 1/2” NPT
Conduit Single
Entry
M1 - Cable Gland
Single Entry
⑤⑦
N2 - 1/2” NPT
Conduit (2 hubs
provided)
M2 - Cable Gland
Feed Thru ⑥⑦
Lighting

08

Number of Lamps:
2 - 2 Lamps

Series:
FR - Wet
Location
FZ - Zone 2,    
AEx nA, Ex
nA
FD - Class I,       
Division 2 ①

Lighting: Enclosed and Gasketed — Area — Fluorescent

4

Mounting
Configuration:
C - Ceiling
P - Pendant

S

126

Ballast Type:
S - Solid State ②

Lamp Length:
4 - 4 Feet

2

F

Number of Ballasts:
Blank - Single
2 - Double

Voltage:
347 - 347 V, 60 Hz V
BU - 120-277 V,
50/60 Hz
(0 °F/-18 °C
start)
  

Lamp Type:
08 - T8, 32 W, 265MA
12 - T12, 40 W, 430MA

Options:
F - Fused ⑧
T - Terminal Blocks ④
P - Polycarbonate 	
lens ③ for IP65
EL- Emergency
Battery Pack

① Fixture is not available with M1 or M2 cable entry options
② Cold weather standard for T8.
③ Use polycarbonate lens for IP65 rating. Polycarbonate lens is standard on FZ Series.
④ Standard equipment for FZ series
⑤ Fixture will be supplied with a 5’/1.5 m length of #14/3 cord and 3 prong plug (120 V) pre-installed when ordered with cable gland. Fixture with cable gland
can only be used with hook and chain mounting.
⑥ ???.
⑦ FZ Series fixtures are not UL Listed for Class I, Division 2 when used with cable glands. FZ Series fixtures are UL Classified for Class I, Zone 2 when used
with cable glands.
⑧ Canadian Electrical Code does NOT allow fusing in hazardous locations V.
V CSA Certification only.

1076

Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

FR™ Enclosed and Gasketed; FZ™ and FD™ Hazardous Locations Luminaires

Nonmetallic Fluorescent. Accessories and Replacement Parts

4 foot, 2 lamp fixtures. High-impact fiberglass reinforced polyester fixtures suitable for use in wet and damp locations.

Item

Description

Catalog Number

Hub
1/2” NPT watertight conduit hub

FHUB

Cable gland

FGLAND

32 W (T8) and 40 W (T12) lampholder

FS0C40

Standard plastic clips

FPCLIP

Acrylic lens cover

FLENS

Polycarbonate lens cover ①

FPLENS

Cable Gland

Lampholder

Lens Clip

Lighting

Lens

Stainless steel bracket with mounting hardware (set of 2)

FBRACKET

11 gauge (1/8”) stainless steel (set of 2)

FVWFM

Lighting: Enclosed and Gasketed — Area — Fluorescent

Ceiling Mounting Bracket (Supplied standard with product)

Fixed 45° Wall Mount

① Polycarbonate lens standard for FZ series. When used with FD series, fixture has an IP65 rating.
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

1077

FR™ Enclosed and Gasketed; FZ™ and FD™ Hazardous Locations Luminaires
Nonmetallic Fluorescent. Dimensions

4 foot, 2 lamp fixtures. High-impact fiberglass reinforced polyester fixtures suitable for use in wet and damp locations.

38.75"/ 984.3 mm

6.50”/
165.1 mm

8.25”/209.6 mm

View of Fixture Cover

50.00”/ 1270 mm

Side View

Fixed 45° Wall Mount — FVWFM
7.44"/

7
-41/9
189.0
mm
4”
1.25"/

Lighting

7.72"/
196.1 mm

7-23/32”

1.50"/
38.1mm

3-9/16”

0.31"/
5/16”
7.9
mm
DIA.
Dia.

5.50"/
139.7 mm

3.56"/
90.4 mm

1-1/4”
31.8 mm

0.25"/
1/4”
6.35
mm
DIA.
Dia.

Lighting: Enclosed and Gasketed — Area — Fluorescent

3.25"/
82.6 mm

View of Fixture Mounting

1078

Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

FR™ Enclosed and Gasketed; FZ™ and FD™ Hazardous Locations Luminaires

Nonmetallic Fluorescent. Photometric Data

4 foot, 2 lamp fixtures. High-impact fiberglass reinforced polyester fixtures suitable for use in wet and damp locations.

Candela Distribution

TOTAL LUMINAIRE EFFICIENCY = 84.6%

REPORT NUMBER: ITL 47240

0.0 22.5 45.0 67.5 90.0 Flux CIE Type – Semi-Direct
0 1155 1155 1155 1155 1155

0˚

Plane:

90˚

5 1159 1153 1150 1148 1148 110 Spacing Criteria: 1.3

Lamps: Two 32 W, 4-foot F32T8/TL735 fluorescents,
2850 lumens per lamp with acrylic lens.

1.5

15 1118 1118 1124 1134 1137 318 Shielding Angles: 1

0

25 1036 1049 1071 1109 1125 498
35

918 945 1010 1087 1114 636

45

766 812 927 1026 1056 710

55

569 652 788 900 927 690

65

342 450 598 719 753 574

75

148 259 432 567 604 434

85

25 133 318 444 473 312

COEFFICIENTS OF UTILIZATION - ZONAL CAVITY METHOD
EFFECTIVE FLOOR CAVITY REFLECTANCE 0.20
% Ceiling RC

80

70

50

30

10

0

90˚ % Walls RW 70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10

4

98 270 376 412

ZONAL LUMEN
SUMMARY

95

5

84 258 372 414 249

ZONE LUMENS

105

2

42 182 292 341 181

0- 30

115

0

13

69 139 182 79

0- 40 1562

125

0

3

22

36

50 21

0- 60 2962

135

0

0

9

15

19

7

0- 90 4282

145

0

0

2

7

9

2

90-120

509

155

0

0

0

0

2

0

90-130

529

165

0

0

0

0

0

0

90-150

538

175

0

0

0

0

0

0

90-180

539

180

0

0

0

0

0

75˚

0 .98 .98 .98 .98 .95 .95 .95 .95 .89 .89 .89 .83 .83 .83 .78 .78 .78 .75
1 .88 .83 .78 .74 .84 .80 .76 .72 .75 .71 .68 .70 .67 .65 .65 .63 .61 .58

400

60˚

926

2 .79 .71 .65 .59 .76 .69 .63 .58 .64 .59 .55 .60 .56 .52 .56 .52 .50 .47
3 .71 .62 .54 .48 .68 .60 .53 .47 .56 .50 .45 .52 .47 .43 .49 .45 .41 .39

800

45˚

4 .65 .54 .46 .40 .62 .52 .45 .39 .49 .43 .38 .46 .41 .36 .43 .38 .35 .32
5 .60 .48 .40 .34 .57 .47 .39 .33 .44 .37 .32 .41 .35 .31 .38 .34 .30 .28
6 .55 .43 .35 .29 .53 .52 .34 .29 .39 .33 .28 .37 .31 .27 .35 .30 .26 .24

1200
0˚

15˚

7 .51 .39 .31 .26 .49 .38 .30 .25 .36 .29 .24 .33 .28 .24 .32 .27 .23 .21

30˚

8 .47 .35 .28 .23 .45 .34 .27 .22 .32 .26 .22 .31 .25 .21 .29 .24 .20 .19

Legend
0-deg
45-deg
90-deg

9 .44 .32 .25 .20 .42 .31 .25 .20 .30 .24 .19 .28 .23 .19 .27 .22 .18 .17
10 .41 .30 .23 .18 .40 .29 .22 .18 .27 .22 .17 .26 .21 .17 .25 .20 .16 .15

0-180 4820

Candela Distribution

TOTAL LUMINAIRE EFFICIENCY = 83.6%

REPORT NUMBER: ITL 47241

0.0 22.5 45.0 67.5 90.0 Flux CIE Type – Semi-Direct
566 566 566 566 566

568 565 564 563 563 54 Spacing Criteria: 1.3

0˚

1.5

15

548 549 550 554 555 156 Shielding Angles: 1

0

25

506 512 523 543 552 243

35

448 461 495 535 549 312

45

374 396 458 509 525 350

55

283 324 399 457 475 349

65

177 241 318 393 409 306

75

72 142 211 259 267 210

Plane:

90˚

Lamps: Two 32 W, 4-foot F32T8/TL735 fluorescents,
2850 lumens per lamp with polycarbonate lens.

COEFFICIENTS OF UTILIZATION - ZONAL CAVITY METHOD
EFFECTIVE FLOOR CAVITY REFLECTANCE 0.20
90˚

85

6

63 150 212 228 146

90

1

46 118 167 186

ZONAL LUMEN
SUMMARY

95

1

43 122 176 198 118

ZONE LUMENS

105

0

20

115

0

125

75˚
190
60˚

% Ceiling RC

80

70

50

30

10

0

% Walls RW 70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10

0

  0 .97 .97 .97 .97 .94 .94 .94 .94 .88 .88 .88 .82 .82 .82 .77 77 77 .75
  1 .87 .82 .78 .74 .84 .79 .75 .72 .74 .71 .68 .69 .67 .64 .65 .63 .61 .58

84 131 154 83

0- 30

453

5

33

74

92 40

0- 40

765

  2 .78 .70 .64 .58 .75 .68 .62 .57 .63 .59 .54 .59 .55 .52 .55 .52 .49 .47

0

1

10

18

24 10

0- 60 1464

135

0

0

5

9

10

4

0- 90 2126

145

0

0

1

4

5

1

90-120

241

155

0

0

0

1

1

0

90-130

251 Legend

  7 .50 .38 .31 .25 .48 .37 .30 .25 .35 .29 .24 .33 .27 .23 .31 .26 .22 .21

165

0

0

0

0

0

0

90-150

256

  8 .46 .35 .27 .22 .45 .34 .27 .22 .32 .26 .21 .30 .25 .21 .28 .24 .20 .18

175

0

0

0

0

0

0

90-180

256

0-deg
45-deg
90-deg

180

0

0

0

0

0

380
45˚

  3 .71 .61 .53 .48 .68 .59 .52 .47 .55 .49 .45 .52 .47 .43 .48 .44 .41 .38
  4 .64. 54 .46 .40 .62 .52 .44 .39 .48 .42 .37 .45 .40 .36 .43 .38 .34 .32
  5 .59 .47 .39 .34 .56 .46 .39 .33 .43 .37 .32 .40 .35 .31 .38 .33 .29 .27

570
0˚

15˚

0-180 2383

Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

30˚

  6 .54 .42 .35 .29 .52 .41 .34 .28 .39 .32 .27 .36 .31 .27 .34 .29 .26 .24

  9 .43 .32 .25 .20 .42 .31 .24 .20 .29 .23 .19 .28 .22 .18 .26 .21 .18 .16
10 .41 .29 .22 .18 .39 .28 .22 .18 .27 .21 .17 .26 .20 .17 .24 .20 .16 .15

1079

Lighting: Enclosed and Gasketed — Area — Fluorescent

0
5

Lighting

90

0

FR™ Enclosed and Gasketed; FZ™ and FD™ Hazardous Locations Luminaires
Nonmetallic Fluorescent. Photometric Data

4 foot, 2 lamp fixtures. High-impact fiberglass reinforced polyester fixtures suitable for use in wet and damp locations.

Candela Distribution

TOTAL LUMINAIRE EFFICIENCY = 80.7%

REPORT NUMBER: ITL 47242

0.0 22.5 45.0 67.5 90.0 Flux CIE Type – Semi-Direct
0 1224 1224 1224 1224 1224

0˚

Plane:

90˚

5 1228 1223 1221 1219 1218 116 Spacing Criteria: 1.3

Lamps: Two 40 W, 4-foot F40WW fluorescents,
3150 lumens per lamp with acrylic lens.

1.5

15 1185 1190 1204 1219 1222 341 Shielding Angles: 1

0

Lighting

25 1097 1122 1158 1200 1214 535
35

974 1020 1090 1166 1192 683

45

811 881 993 1094 1122 759

55

600 701 837 943 967 729

65

358 476 625 736 761 595

75

154 271 443 566 600 441

85

25 136 325 455 490 321

COEFFICIENTS OF UTILIZATION - ZONAL CAVITY METHOD
EFFECTIVE FLOOR CAVITY REFLECTANCE 0.20
90˚

90

5 101 285 401 442

ZONAL LUMEN
SUMMARY

95

5

84 260 372 415 253

ZONE LUMENS

105

2

45 187 294 343 184

0- 30

115

0

14

125

0

135

75˚
450
60˚

992

80

70

50

30

10

% Walls RW 70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10

0
0

0 .94 .94 .94 .94 .91 .91 .91 .91 .85 .85 .85 .79 .79 .79 .74 .74 .74 .72
1 .84 .79 .75 .71 .81 .76 .73 .69 .71 .68 .65 .67 .64 .62 .62 .60 .58 .56
2 .76 .68 .62 .57 .72 .66 .60 .55 .61 .57 .53 .57 .53 .50 .54 .50 .48 .45

900

85 163 204

91

0- 40 1676

3

23

53

81

28

0- 60 3164

0

0

9

16

20

7

0- 90 4521

145

0

0

0

5

7

2

90-120

528

155

0

0

0

0

0

0

90-130

556 Legend

7 .49 .37 .30 .25 .47 .36 .29 .24 .34 .28 .24 .32 .27 .23 .30 .26 .22 .20

165

0

0

0

0

0

0

90-150

564

8 .45 .34 .27 .22 .43 .33 .26 .22 .31 .25 .21 .29 .24 .20 .28 .23 .20 .18

175

0

0

0

0

0

0

90-180

564

0-deg
45-deg
90-deg

180

0

0

0

0

0

45˚

0˚

15˚

9 .42 .31 .24 .20 .40 .30 .24 .19 .29 .23 .19 .27 .22 .18 .26 .21 .18 .16
10 .39 .28 .22 .18 .38 .28 .22 .17 .26 .21 .17 .25 .20 .16 .24 .19 .16 .14

REPORT NUMBER: ITL 47243

0.0 22.5 45.0 67.5 90.0 Flux CIE Type – Semi-Direct
0˚

Plane:

4 .62 .52 .44 .39 .60 .50 .43 .38 .47 .41 .36 .44 .39 .35 .41 .37 .33 .31
6 .53 .41 .34 .28 .50 .40 .33 .28 .38 .32 .27 .35 .30 .26 .33 .29 .25 .23

30˚

TOTAL LUMINAIRE EFFICIENCY = 78.9%

0 1188 1188 1188 1188 1188

3 .68 .59 .52 .46 .66 .57 .51 .45 .53 .48 .43 .50 .45 .41 .47 .43 .40 .37
5 .57 .46 .39 .33 .55 .45 .38 .32 .42 .36 .31 .39 .34 .30 .37 .32 .29 .27

1350

0-180 5085

Candela Distribution

Lighting: Enclosed and Gasketed — Area — Fluorescent

% Ceiling RC

90˚

5 1188 1186 1186 1184 1183 113 Spacing Criteria: 1.3

Lamps: Two 40 W, 4-foot F40WW fluorescents,
3150 lumens per lamp with polycarbonate lens.

1.5

15 1146 1155 1165 1177 1181 330 Shielding Angles: 1

0

25 1060 1085 1122 1165 1178 519
35

940 984 1055 1135 1161 663

45

782 850 970 1073 1102 738

55

589 687 836 950 977 725

65

367 500 652 765 791 618

75

145 293 437 548 563 431

85

12 132 306 428 464 302

COEFFICIENTS OF UTILIZATION - ZONAL CAVITY METHOD
EFFECTIVE FLOOR CAVITY REFLECTANCE 0.20
90˚

% Ceiling RC

80

70

50

30

10

% Walls RW 70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10

0
0

90

4 106 270 381 421

ZONAL LUMEN
SUMMARY

95

5

86 244 348 389 240

ZONE LUMENS

105

2

42 178 278 321 172

115

0

8

82 163 201

88

0- 40 1624

125

0

1

19

54

82

27

0- 60 3087

135

0

0

8

16

18

6

0- 90 4438

145

0

0

1

5

8

2

90-120

500

155

0

0

0

0

0

0

90-130

527 Legend

7 .47 .36 .29 .24 .46 .35 .29 .24 .33 .27 .23 .31 .26 .22 .30 .25 .21 .20

165

0

0

0

0

0

0

90-150

535

8 .44 .33 .26 .21 .42 .32 .26 .21 .30 .25 .20 .29 .23 .20 .27 .23 .19 .17

175

0

0

0

0

0

0

90-180

535

0-deg
45-deg
90-deg

180

0

0

0

0

0

1080

0- 30

75˚
400

60˚

961

0-180 4973

0 .92 .92 .92 .92 .89 .89 .89 .89 .83 .83 .83 .78 .78 .78 .73 .73 .73 .70
1 .82 .78 .74 .70 .79 .75 .71 .68 .70 .67 .64 .65 .63 .61 .61 .59 .57 .55
2 .74 .67 .61 .55 .71 .64 .59 .54 .60 .55 .52 .56 .52 .49 .53 .49 .47 .44

800

45˚

3 .67 .58 .51 .45 .64 .56 .49 .44 .52 .47 .42 .49 .44 .41 .46 .42 .39 .37
4 .61 .51 .43 .38 .58 .49 .42 .37 .46 .40 .35 .43 .38 .34 .40 .36 .33 .31
5 .56 .45 .38 .32 .53 .44 .37 .31 .41 .35 .30 .38 .33 .29 .36 .32 .28 .26

1200

0˚

15˚

30˚

6 .51 .40 .33 .28 .49 .39 .32 .27 .37 .31 .26 .35 .29 .25 .33 .28 .24 .23

9 .41 .30 .24 .19 .39 .29 .23 .19 .28 .22 .18 .26 .21 .18 .25 .20 .17 .16
10 .38 .28 .21 .17 .37 .27 .21 .17 .26 .20 .16 .24 .19 .16 .23 .19 .15 .14

Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

FE Series Nonmetallic Fluorescent Luminaires

Standard and Emergency Battery Back-Up. Increased Safety
Zone 1 & 2 – 21 & 22
II 2 GD
ATEX / IECEx
IP66/67 – IK10

Applications
•	 Can be installed in hazardous areas designated as Zone 1, 2, 21
and 22.
•	 For use in locations where a high degree of corrosion resistance
is required.
•	 For indoor/outdoor use where protection against dirt, water and
moisture is necessary.
•	 Typical applications include oil refineries, petrochemical
facilities, pulp and paper mills, food processing plants,
warehouses, underground tunnels and general manufacturing
facilities.

2 x 58 W

Features

•	
•	
•	
•	
•	

Fiberglass reinforced polyester housing
Polycarbonate lens
Elastomer gasket
Highly reflective white polycarbonate internal reflector
Mounting accessories available in different materials such as
gray painted aluminum, zinc plated steel, galvanized steel or
316 stainless steel

Options
•	 Silicone coating for added protection in H2S hydrogen sulfide
environments.
•	 Without safety switch.
•	 Level gauge light fitting.
•	 316 stainless steel fixing inserts.

2 x 18 W

EOL

Approved

Certifications and Compliances
•	
•	
	
	
	
•	
	
	
	
•	
•	
•	
•	
•	
•	
•	
•	
•	
•	
•	

Certification Type: FLe
Zones 1 and 2
— Conforming to ATEX 94/9/CE: CE 0081
II 2 G
— ATEX/IEC Protection: Ex de IIC or Ex demb IIC 	
    (emergency version)
— T Rating: T5 ① to T4
Zone 21 and 22
— Conforming to ATEX 94/9/CE: CE 0081
II 2 D
— ATEX/IEC Protection: Ex tD A21
— Surface Temperature: 167 °F/75 °C
Ambient Temperature: -40 °F to 131 °F / -40 °C to 55 °C
CE Declaration of Conformity: 50201
ATEX Certificate: LCIE 07 ATEX 6017
IECEx Certificate: LCIE Ex 04.0017
Other Certifications: GOST, Marine Listed UL 1598A
Index of Protection (solid & liquid): IP66/67
Impact Resistance (shock): IK10
Ex Standards: EN / IEC 60079-0; 60079-1; 60079-7; 60079-18;
61241-0; 61241-1
Product Standards: EN / IEC 60598-1; 60598-2-22
EMC Standards: EN / IEC 55015; 61547
Other Standards: EN / IEC 60529 (IP); 62262 (IK)

① With ceiling position use at 104 °F/40 °C ambient temperature
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

1081

Lighting: Enclosed and Gasketed — Area — Fluorescent

Standard Materials

2 x 36 W

Lighting

•	 Corrosion-resistant fiberglass reinforced polyester body and
hinged polycarbonate lens.
•	 High impact resistance housing (20 Joules – IK10) from -40 °F to
131 °F / -40 °C to 55 °C ambient temperature and wind profile
for use in extreme offshore and onshore environments.
•	 Latch assembly and elastomer gasket seals against water and
dust ingress, IP66/67.
•	 Easily accessed for maintenance using Allen key or straight
blade screwdriver.
•	 Central opening with unique patented release system to prevent
damage.
•	 Hinged parabolic reflector for high lumen output efficiency.
•	 Vibration resistant spring loaded lampholders for bi-pin (G13) or
mono-pin (Fa6) versions.
•	 Positive safety switch disconnects power to lamps and ballast
to allow maintenance in hazardous locations.
•	 Electronic multi-tap ballast 110 to 254 Vac/Vdc +/- 10%  50/60
Hz, for global applications. High power factor electronic ballast
(>0.95). EOL (End Of Life) protection in accordance to the latest
EN/IEC 60079-7 standard.
•	 Two channel ballast prevents dark areas by allowing one lamp to
remain lit if one fails.
•	 Ballast plug-in with Ex e connector for quick and error-free
maintenance.
•	 Available in 3 hours emergency version, including multi-tap
ballast with built-in monthly self test. Test results through multicolored LED.
•	 Ex e battery with plug-in connector for maintenance in
hazardous location.

FE Series Nonmetallic Fluorescent Luminaires

Standard and Emergency Battery Back-Up. Increased Safety
Zone 1 & 2 – 21 & 22
II 2 GD
ATEX / IECEx
IP66/67 – IK10

Illustrated Features

Can be mounted horizontally or vertically

Order using catalog numbering guide below or select catalog number from tables on following pages.
Catalog Numbering Guide For FE Nonmetallic Fluorescent Lighting Fixtures
FE

B

1

Lighting

Series:
FE - FE Series
Zone 1, 2, 21, 22
ATEX / IEC Certified

BU

P

Wattage:
18 - 18 Watt
36 - 36 Watt
58 - 58 Watt

Lamp Type:
B - Bi-pin (G13)
M - Mono Pin (Fa6)

Lighting: Enclosed and Gasketed — Area — Fluorescent

18

Number of Lamps:
1 - Single
2 - Double
3 - Three Lamps

A

C

Cable Type:
A - Armored M20
N - Unarmored M25
U - Unarmored M20

Voltage:
BU - 110 to 254 Vac/Vdc
50/60 Hz
BK - 220 to 240 Vac/Vdc
50/60 Hz

Cable Type:
A - Armored M20
N - Unarmored M25
U - Unarmored M20

Mounting Version:
P - Pole Mount ①
S - Surface/Suspension Mount
Standard Wiring
T - Surface/Suspension Mount
Through Wiring
L - Surface/Suspension Mount
Dual Loop in/out Through
Wiring (single phase)

① Only 2 x 18 W and 2 x 36 W with M25 entry versions.
② Only 36 W and 58 W emergency versions.
③ Only for single standard versions.
④ Only for standard versions.
⑤ Only for S, T and L mounting versions.

1082

Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

FE Series Nonmetallic Fluorescent Luminaires

Standard and Emergency Battery Back-Up. Increased Safety
Zone 1 & 2 – 21 & 22
II 2 GD
ATEX / IECEx
IP66/67 – IK10

Surface/Suspension Mounting and Standard Wiring Version
Connection via 1 x 6 terminals.
Capacity (flexible/solid): 4 mm2/6 mm2.
Unarmored Version - Bi-pin (G13)
Three M25 threaded entries, two at one end and one at opposite end, supplied with one 	
M25 polyamide cable gland (dia. 0.31 to 0.73" / 8 to 18.5 mm) and two M25 polyamide plugs.
Number
of Lamps

Power
(W)

Lamp
Type

Voltage
(V)

Weight
(lbs/kg)

Volume
(in3/dm3)

Catalog
Number

1

18

G13

110/254

12.13/5.5

1971.07/32.3

FEB118BUSN

2

18

G13

110/254

12.13/5.5

1971.07/32.3

FEB218BUSN

1

36

G13

110/254

17.42/7.9

3307.49/54.2

FEB136BUSN

2

36

G13

110/254

17.42/7.9

3307.49/54.2

FEB236BUSN

3

36

G13

110/254

21.83/9.9

3307.49/54.2

FEB336BUSN

1

58

G13

110/254

19.84/9

3966.54/65

FEB158BUSN

2

58

G13

110/254

19.84/9

3966.54/65

FEB258BUSN

3

58

G13

110/254

24.3/11

3966.54/65

FEB358BUSN

Armored Version - Bi-pin (G13)
Two M20 threaded entries with brass earth continuity plate at one end and 	
one M20 plugged clearance entry, supplied with two M20 polyamide plugs.
Lamp
Type

Voltage
(V)

Weight
(lbs/kg)

Volume
(in3/dm3)

Catalog
Number

1

18

G13

110/254

12.13/5.5

1971.07/32.3

FEB118BUSA

2

18

G13

110/254

12.13/5.5

1971.07/32.3

FEB218BUSA

1

36

G13

110/254

17.42/7.9

3307.49/54.2

FEB136BUSA

2

36

G13

110/254

17.42/7.9

3307.49/54.2

FEB236BUSA

3

36

G13

110/254

21.83/9.9

3307.49/54.2

FEB336BUSA

1

58

G13

110/254

19.84/9

3966.54/65

FEB158BUSA

2

58

G13

110/254

19.84/9

3966.54/65

FEB258BUSA

3

58

G13

110/254

24.3/11

3966.54/65

FEB358BUSA

Unarmored Version - Mono-pin (Fa6)
Three M25 threaded entries, two at one end and one at opposite end, supplied with 	
one M25 polyamide cable gland (dia. 0.31 to 0.73" / 8 to 18.5 mm) and two M25 polyamide plugs.
Catalog
Number

Number
of Lamps

Power
(W)

Lamp
Type

Voltage
(V)

Weight
(lbs/kg)

Volume
(in3/dm3)

2

18

Fa6

110/254

12.13/5.5

1971.07/32.3

FEM218BUSN

2

36

Fa6

110/254

17.42/7.9

3307.49/54.2

FEM236BUSN

2

58

Fa6

110/254

19.84/9

3966.54/65

FEM258BUSN

Armored Version - Mono-pin (Fa6)
Two M20 threaded entries with brass earth continuity plate at one end and one M20 	
plugged clearance entry supplied with two M20 polyamide plugs.
Catalog
Number

Number
of Lamps

Power
(W)

Lamp
Type

Voltage
(V)

Weight
(lbs/kg)

Volume
(in3/dm3)

2

18

Fa6

110/254

12.13/5.5

1971.07/32.3

FEM218BUSA

2

36

Fa6

110/254

17.42/7.9

3307.49/54.2

FEM236BUSA

2

58

Fa6

110/254

19.84/9

3966.54/65

FEM258BUSA

Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

1083

Lighting: Enclosed and Gasketed — Area — Fluorescent

Power
(W)

Lighting

Number
of Lamps

FE Series Nonmetallic Fluorescent Luminaires

Standard and Emergency Battery Back-Up. Increased Safety
Zone 1 & 2 – 21 & 22
II 2 GD
ATEX / IECEx
IP66/67 – IK10

Surface/Suspension Mounting and Through Wiring Version (three phase)
Connection via 2 x 5 terminals.
Capacity (flexible/solid): 0.006 in2/0.009 in2 / 4 mm2/6 mm2.

Unarmored Version - Bi-pin (G13)
Three M25 threaded entries, two at one end and one at opposite end, supplied with two M25 polyamide cable
gland (dia. 0.31 to 0.73" / 8 to 18.5 mm) and one M25 polyamide plug.
Number
of Lamps

Power
(W)

Lamp
Type

Voltage
(V)

Weight
(lbs/kg)

Volume
(in3/dm3)

Catalog
Number

2

18

G13

110/254

12.13/5.5

1971.07/32.3

FEB218BUTN

2

36

G13

110/254

17.42/7.9

3307.49/54.2

FEB236BUTN

2

58

G13

110/254

19.84/9

3966.54/65

FEB258BUTN

Lighting: Enclosed and Gasketed — Area — Fluorescent

Lighting

Armored Version - Bi-pin (G13)
Two M20 threaded entries with brass earth continuity plate at one end and one M20 threaded 	
entry with brass earth continuity plate at opposite end, supplied with one M20 polyamide plug.
Number
of Lamps

Power
(W)

Lamp
Type

Voltage
(V)

Weight
(lbs/kg)

Volume
(in3/dm3)

Catalog
Number

2

18

G13

110/254

12.13/5.5

1971.07/32.3

FEB218BUTA

2

36

G13

110/254

17.42/7.9

3307.49/54.2

FEB236BUTA

2

58

G13

110/254

19.84/9

3966.54/65

FEB258BUTA

Surface/Suspension Mounting and Dual Loop In/Out Through
Wiring Version (single phase):
Connection via 1 x 6 terminals and 1 x 3 terminals.
Capacity (flexible/solid): 0.006in2/0.009in2 / 4 mm2/6 mm2.

Unarmored Version - Bi-pin (G13)
Three M25 entries, two at one end and one at opposite end, supplied with two M25 polyamide cable glands
(dia. 8 to 18.5 mm) and one M25 polyamide plug.
Number
of Lamps

Power
(W)

Lamp
Type

Voltage
(V)

Weight
(lbs/kg)

Volume
(in3/dm3)

Catalog
Number

2

18

G13

110/254

12.13/5.5

1971.07/32.3

FEB218BULN

2

36

G13

110/254

17.42/7.9

3307.49/54.2

FEB236BULN

2

58

G13

110/254

19.84/9

3966.54/65

FEB258BULN

Armored Version - Bi-pin (G13)
Two M20 threaded entries with brass earth continuity plate at one end and one M20 threaded 	
entry with brass earth continuity plate at opposite end, supplied with one M20 polyamide plug.
Number
of Lamps

Power
(W)

Lamp
Type

Voltage
(V)

Weight
(lbs/kg)

Volume
(in3/dm3)

Catalog
Number

2

18

G13

110/254

12.13/5.5

1971.07/32.3

FEB218BULA

2

36

G13

110/254

17.42/7.9

3307.49/54.2

FEB236BULA

2

58

G13

110/254

19.84/9

3966.54/65

FEB258BULA

1084

Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

FE Series Nonmetallic Fluorescent Luminaires

Standard and Emergency Battery Back-Up. Increased Safety
Zone 1 & 2 – 21 & 22
II 2 GD
ATEX / IECEx
IP66/67 – IK10

Pole Mounting Version
Connection via 1 x 3 terminals.
Capacity (flexible/solid): 0.006 in2/0.009 in2 / 4 mm2/6 mm2.
For mounting on dia. 1.65"/42 mm pole or tubular wall-mounting support, 	
supplied with one integrated M25 polyamide cable gland 	
(dia. 0.31 to 0.73" / 8 to 18.5 mm).

Number
of Lamps

Power
(W)

Lamp
Type

Voltage
(V)

Weight
(lbs/kg)

Volume
(in3/dm3)

Catalog
Number

2

18

G13

110/254

13.67/6.2

2080.91/34.1

FEB218BUPN

2

36

G13

110/254

19.18/8.7

3307.49/54.2

FEB236BUPN

Level Gauge Tank Light Surface/Suspension Mounting with Standard Wiring
Connection via 1 x 6 terminals.
Capacity (flexible/solid):  0.006 in2/0.009 in2 / 4 mm2/6 mm2.
Unarmored Version - Bi-pin (G13)
Three M25 entries, two at one end and one at opposite end, supplied with 	
one M25 polyamide cable gland (dia. 0.31 to 0.73" / 8 to 18.5 mm) and two M25 polyamide plugs.
Power
(W)

Lamp
Type

Voltage
(V)

Weight
(lbs/kg)

Volume
(in3/dm3)

1

18

G13

110/254

12.13/5.5

1971.07/32.3

FEB118BUSNL

1

36

G13

110/254

17.42/7.9

3307.49/54.2

FEB136BUSNL

1

58

G13

110/254

19.84/9

3966.54/65

FEB158BUSNL

Catalog
Number

Lighting

Number
of Lamps

Lighting: Enclosed and Gasketed — Area — Fluorescent

Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

1085

FE Series Nonmetallic Fluorescent Luminaires

Standard and Emergency Battery Back-Up. Increased Safety
Zone 1 & 2 – 21 & 22
II 2 GD
ATEX / IECEx
IP66/67 – IK10

Surface/Suspension Mounting and Standard Wiring
Connection via 1 x 4 terminals for 18 W version.
Connection via 1 x 8 terminals for 	
36 W & 58 W versions.
Capacity (flexible/solid): 0.006 in2/0.009 in2 /
4 mm2/6 mm2.
Unarmored Version - Bi-pin (G13)
Three M25 entries, two at one end and one at
opposite end, supplied with one 	
M25 polyamide cable gland (dia. 0.31 to 0.73" / 	
8 to 18.5 mm) and two M25 polyamide plugs.
Number
of Lamps

Power
(W)

Lamp
Type

Voltage
(V)

Weight
(lbs/kg)

Volume
(in3/dm3)

Duration
(Hours)

Battery
Capacity

2
2
2
3
2
2
3

18
36
36
36
58
58
58

G13
G13
G13
G13
G13
G13
G13

110/254
110/254
110/254
110/254
110/254
110/254
110/254

16.09/7.3
21.16/9.6
21.16/9.6
25.57/11.6
23.59/10.7
23.59/10.7
28.00/12.7

1971.07/32.3
3307.49/54.2
3307.49/54.2
3307.49/54.2
3966.54/65
3966.54/65
3966.54/65

3H
3H
3H
3H
3H
3H
3H

4Ah
4Ah
7Ah
4Ah
4Ah
7Ah
4Ah

Catalog
Number
FEB218BUSNE
FEB236BUSNE
FEB236BUSNE7
FEB336BUSNE
FEB258BUSNE
FEB258BUSNE7
FEB358BUSNE

Lighting: Enclosed and Gasketed — Area — Fluorescent

Lighting

Armored Version - Bi-pin (G13)
Two M20 threaded entries with brass earth continuity plate at one end and one 	
M20 plugged clearance entry, supplied with two M20 polyamide plugs.
Number
of Lamps

Power
(W)

Lamp
Type

Voltage
(V)

Weight
(lbs/kg)

Volume
(in3/dm3)

Duration
(Hours)

Battery
Capacity

2
2
2
3
2
2
3

18
36
36
36
58
58
58

G13
G13
G13
G13
G13
G13
G13

110/254
110/254
110/254
110/254
110/254
110/254
110/254

16.09/7.3
21.16/9.6
21.16/9.6
25.57/11.6
23.59/10.7
23.59/10.7
28.00/12.7

1971.07/32.3
3307.49/54.2
3307.49/54.2
3307.49/54.2
3966.54/65
3966.54/65
3966.54/65

3H
3H
3H
3H
3H
3H
3H

4 Ah
4 Ah
7 Ah
4 Ah
4 Ah
7 Ah
4 Ah

Catalog
Number
FEB218BUSAE
FEB236BUSAE
FEB236BUSAE7
FEB336BUSAE
FEB258BUSAE
FEB258BUSAE7
FEB358BUSAE

Unarmored Version - Mono-pin (Fa6)
Three M25 entries, two at one end and one at opposite end, supplied with one 	
M25 polyamide cable gland (dia. 0.31 to 0.73" / 8 to 18.5 mm) and two M25 polyamide plugs.
Number
of Lamps

Power
(W)

Lamp
Type

Voltage
(V)

Weight
(lbs/kg)

Volume
(in3/dm3)

Duration
(Hours)

Battery
Capacity

2
2
2
2
2

18
36
36
58
58

Fa6
Fa6
Fa6
Fa6
Fa6

110/254
110/254
110/254
110/254
110/254

16.76/7.6
21.83/9.9
21.83/9.9
24.25/11
24.25/11

1971.07/32.3
3307.49/54.2
3307.49/54.2
3966.54/65
3966.54/65

3H
3H
3H
3H
3H

4 Ah
4 Ah
7 Ah
4 Ah
7 Ah

Catalog
Number
FEM218BUSNE
FEM236BUSNE
FEM236BUSNE7
FEM258BUSNE
FEM258BUSNE7

Armored Version - Mono-pin (Fa6)
Two M20 threaded entries with brass earth continuity plate at one end and one 	
M20 plugged clearance entry, supplied with two M20 polyamide plugs.
Number
of Lamps

Power
(W)

Lamp
Type

Voltage
(V)

Weight
(lbs/kg)

Volume
(in3/dm3)

Duration
(Hours)

Battery
Capacity

2
2
2
2
2

18
36
36
58
58

Fa6
Fa6
Fa6
Fa6
Fa6

110/254
110/254
110/254
110/254
110/254

16.76/7.6
21.83/9.9
21.83/9.9
24.25/11
24.25/11

1971.07/32.3
3307.49/54.2
3307.49/54.2
3966.54/65
3966.54/65

3H
3H
3H
3H
3H

4 Ah
4 Ah
7 Ah
4 Ah
7 Ah

1086

Catalog
Number
FEM218BUSAE
FEM236BUSAE
FEM236BUSAE7
FEM258BUSAE
FEM258BUSAE7

Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

FE Series Nonmetallic Fluorescent Luminaires

Standard and Emergency Battery Back-Up. Increased Safety
Zone 1 & 2 – 21 & 22
II 2 GD
ATEX / IECEx
IP66/67 – IK10

Surface/Suspension Mounting and Through Wiring Version
Connection via 2 x 4 terminals.
Capacity (flexible/solid):0.006 in2/0.009 in2 / 4 mm2/6 mm2.
Unarmored Version - Bi-pin (G13):
Three M25 entries, two at one end and one at opposite end, supplied 	
with two M25 polyamide cable glands (dia. 0.31 to 0.73" / 8 to 18.5 mm)
and one M25 polyamide plug.
Number
of Lamps

Power
(W)

Lamp
Type

Voltage
(V)

Weight
(lbs/kg)

Volume
(in3/dm3)

Duration
(Hours)

Battery
Capacity

2

18

Bi-pin

110/254

16.09/7.3

1971.07/32.3

3H

4 Ah

Catalog
Number
FEB218BUTNE

2

36

Bi-pin

110/254

21.16/9.6

3307.49/54.2

3H

4 Ah

FEB236BUTNE

2

36

Bi-pin

110/254

21.16/9.6

3307.49/54.2

3H

7 Ah

FEB236BUTNE7

2

58

Bi-pin

110/254

23.59/10.7

3966.54/65

3H

4 Ah

FEB258BUTNE

2

58

Bi-pin

110/254

23.59/10.7

3966.54/65

3H

7 Ah

FEB258BUTNE7

Armored Version - Bi-pin (G13):
Two M20 threaded entries with brass earth continuity plate at one end and one M20 threaded entry with brass earth continuity plate
at opposite end, supplied with one M20 polymaide plug.
Number
of Lamps

Power
(W)

Lamp
Type

Voltage
(V)

Weight
(lbs/kg)

Volume
(in3/dm3)

Duration
(Hours)

Battery
Capacity

Catalog
Number

18

Bi-pin

110/254

16.09/7.3

1971.07/32.3

3H

4 Ah

FEB218BUTAE

36

Bi-pin

110/254

21.16/9.6

3307.49/54.2

3H

4 Ah

FEB236BUTAE

2

36

Bi-pin

110/254

21.16/9.6

3307.49/54.2

3H

7 Ah

FEB236BUTAE7

2

58

Bi-pin

110/254

23.59/10.7

3966.54/65

3H

4 Ah

FEB258BUTAE

2

58

Bi-pin

110/254

23.59/10.7

3966.54/65

3H

7 Ah

FEB258BUTAE7

Lighting

2
2

Lighting: Enclosed and Gasketed — Area — Fluorescent

Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

1087

FE Series Nonmetallic Fluorescent Luminaires

Standard and Emergency Battery Back-Up. Increased Safety
Zone 1 & 2 – 21 & 22
II 2 GD
ATEX / IECEx
IP66/67 – IK10

Surface/Suspension Mounting and Dual Loop
In/Out Through Wiring Version (single phase)
Connection via 1 x 4 double deck terminals for
18 W version.
Connection via 1 x 8 terminals and 1 x 4
terminals for 36 W & 58 W versions.
Capacity (flexible/solid): 0.006 in2/0.009 in2 /
4 mm2/6 mm2.

or

Lighting: Enclosed and Gasketed — Area — Fluorescent

Lighting

Unarmored Version - Bi-pin (G13)
Three M25 entries, two at one end and one
at opposite end, supplied with two M25
polyamide cable glands (dia. 0.31 to 0.73" / 	
8 to 18.5 mm) and one M25 polyamide plug.

18 W

36/58 W

Number
of Lamps

Power
(W)

Lamp
Type

Voltage
(V)

Weight
(lbs/kg)

Volume
(in3/dm3)

Duration
(Hours)

Battery
Capacity

Catalog
Number

2

18

Bi-pin

110/254

16.76/7.6

1971.07/32.3

3H

4 Ah

FEB218BULNE

2

36

Bi-pin

110/254

21.83/9.9

3307.49/54.2

3H

4 Ah

FEB236BULNE

2

36

Bi-pin

110/254

21.83/9.9

3307.49/54.2

3H

7 Ah

FEB236BULNE7

2

58

Bi-pin

110/254

23.59/10.7

3966.54/65

3H

4 Ah

FEB258BULNE

2

58

Bi-pin

110/254

23.59/10.7

3966.54/65

3H

7 Ah

FEB258BULNE7

Armored Version - Bi-pin (G13)
Two M20 threaded entries with brass earth continuity plate at one end and one M20 	
threaded entry with brass earth continuity plate at opposite end, supplied with one M20 polyamide plug.
Number
of Lamps

Power
(W)

Lamp
Type

Voltage
(V)

Weight
(lbs/kg)

Volume
(in3/dm3)

Duration
(Hours)

Battery
Capacity

Catalog
Number

2

18

Bi-pin

110/254

16.76/7.6

1971.07/32.3

3H

4 Ah

FEB218BULAE

2

36

Bi-pin

110/254

21.83/9.9

3307.49/54.2

3H

4 Ah

FEB236BULAE

2

36

Bi-pin

110/254

21.83/9.9

3307.49/54.2

3H

7 Ah

FEB236BULAE7

2

58

Bi-pin

110/254

23.59/10.7

3966.54/65

3H

4 Ah

FEB258BULAE

2

58

Bi-pin

110/254

23.59/10.7

3966.54/65

3H

7 Ah

FEB258BULAE7

Pole Mounting Version
Connection via 1 x 4 terminals.
Capacity (flexible/solid): 4 mm2/6 mm2.

18 W - Actual Size 2'/0.6m

36 W - Actual Size 4'/1.2m

For mounting on dia. 42 mm pole or tubular wall-mounting support, supplied with 	
one x M25 polyamide cable gland (dia. 0.31 to 0.73" / 8 to 18.5 mm).
Number
of Lamps

Power
(W)

Lamp
Type

Voltage
(V)

Weight
(lbs/kg)

Volume
(in3/dm3)

Duration
(Hours)

Battery
Capacity

Catalog
Number

2

18

Bi-pin

110/254

22.05/10

3307.49/54.2

3H

4 Ah

FEB218BUPNE

2

36

Bi-pin

110/254

22.93/10.4

3307.49/54.2

3H

4 Ah

FEB236BUPNE

2

36

Bi-pin

110/254

22.93/10.4

3307.49/54.2

3H

4 Ah

FEB236BUPNE7

Note: 2 x 18 W is supplied with external battery pack (see dimensional data).

1088

Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

FE Series Nonmetallic Fluorescent Luminaires Accessories

Standard and Emergency Battery Back-Up. Increased Safety

Description

Pack

Catalog Number

Fixing Brackets
Set of two brackets for surface installation
Zinc plated steel

1

FEFBZ

316 stainless steel

1

FEFBS

Aluminum (gray painted)

1

FESBA

316 stainless steel

1

FESBS

1

FERBM8Z

Brackets for Surface Mounting
Set of two

M8 Ring Bolts
Set of two
Zinc plated steel

Half Clamps Brackets for Pole Mounting
Set of two
Dia. 1.65 to 1.93" / 42 to 49 mm pole (1.25 to 1.5" / 31.8 to 38.1 mm tube)
1

FEHC49Z

316 stainless steel

1

FEHC49S

Zinc plated steel

1

FEHC60Z

316 stainless steel

1

FEHC60S

1

FEWMG

Aluminum

1

FEHBA

316 stainless steel

1

FEHBS

Lighting

Zinc plated steel

Dia. 2.36"/60 mm pole (2"/50.8mm tube)

Lighting: Enclosed and Gasketed — Area — Fluorescent

Wall Mounting Adaptor
For pole mounting version (dia. 1.65"/42 mm)
Galvanized steel
Hinged Brackets
Set of two brackets for adjusting luminaire

Fall Prevention Kit
Safety chain retains fixture temporarily to ease installation
For M25 cable entry

1

FESCM25

For M20 cable entry

1

FESCM20

1

096905

Adaptor for Fa8 Tube on Fa6 Lampholder

Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

1089

FE Series Nonmetallic Fluorescent Luminaire Technical Data

Standard and Emergency Battery Back-Up. Increased Safety
Zone 1 & 2 – 21 & 22
II 2 GD
ATEX / IECEx
IP66/67 – IK10

Wiring Diagram

Emergency Function Diagram
Two Lamp Version

Mains
PE	

N	

Mains

L
Lighting
Switch

Lighting Switch ON

Lighting Switch OFF

Lighting Switch ON

Lighting Switch OFF

ON

L’

U
N
PE

Standard Fluorescent
Lighting Fixture

OFF
Three Lamp Version
Mains

U’
U
N
PE

Emergency Fluorescent
Lighting Fixture

ON

Lighting

OFF

LED Status

Lighting: Enclosed and Gasketed — Area — Fluorescent

Color

Indication

Function

LED glows

Batteries are connected

LED blinks

Batteries are charged

Red

LED blinks

Batteries are not connected or defect

Yellow

LED blinks

Batteries are charging and discharging during automatic cycle

Green

Emergency Light Duration
Version
2 x 18 W
2 x 36 W
2 x 58 W

1090

Battery Capacity

Duration

Light Output

4 Ah – 6 V

3 hours

45%

4 Ah – 6 V

3 hours

15%

7 Ah – 6 V

3 hours

25%

4 Ah – 6 V

3 hours

9%

7 Ah – 6 V

3 hours

15%

Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

FE Series Nonmetallic Fluorescent Luminaire Dimensions

Standard and Emergency Battery Back-Up. Increased Safety

Dimensions in Inches/Millimeters
Surface/Suspension Mounting
18 Watt

36 Watt
2 X MB

15.75"/
400.0 mm

2 X MB

27.56"/ 700.0 mm

54.72"/ 1390.0 mm

30.91"/785.0 mm

58 Watt

End View
2 X MB

27.56"/ 700.0 mm

5.71"/
145.0 mm
8.54"/
217.0 mm

66.54"/ 1690.0 mm

Pole Mounting
18 Watt
10.19"/
258.8
258.8
mm

Lighting

Ø 1.65"/
42.0 mm

End View

5.71"/
145.0 mm

1.99"/
50.0 mm

8.58”/
218.0 mm
30.91"/ 785.0 mm

36 Watt

Lighting: Enclosed and Gasketed — Area — Fluorescent

1.99"/
50.0 mm

54.72"/ 1390.0 mm

Emergency Pole Mounting
18 Watt
Ø 1.65"/
42.0 mm

End View

10.19"/
258.8 mm
3.58"/
91.0 mm

1.99"/
50.0 mm

4.72"/
120.0 mm
30.91"/ 785.0 mm

5.71"/
145.0 mm
8.58”/
218.0 mm

39.37"/ 1000.0 mm

Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

1091

FE Series Nonmetallic Fluorescent Luminaires

Standard and Emergency Battery Back-Up. Increased Safety
Zone 1 & 2 – 21 & 22
II 2 GD
ATEX / IECEx
IP66/67 – IK10

Set of two quick fixing brackets for ease of surface
mounting Zinc plated steel or stainless steel

2.52"/
64 mm

0.35"/
9.0 mm

8.5

1.18"/
30 mm

0.33"/
8.5 mm

0.16"/
9.0 mm

0.98"/ 25.0 mm
1.93"/ 49.0 mm

Lighting

Set of two brackets for surface mounting.
Gray painted aluminum or stainless steel.
9.13"/ 232 mm

0.51"/
13.0 mm
0.37"/
9.59.5
mm

1.26"/
32.0 mm
0.57"/ 14.5 mm
14.5

Set of two ring bolts.
Zinc plated steel.

0.79"/
20.0 mm

0.31"/
8.0 mm

0.59"/
1.42"/
15.0 mm 36.0 mm

Lighting: Enclosed and Gasketed — Area — Fluorescent

1.50"/
38.0 mm

7.87"/ 200 mm

M 8 x 1.25

1092

Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

FE Series Nonmetallic Fluorescent Luminaires

Standard and Emergency Battery Back-Up. Increased Safety
Zone 1 & 2 – 21 & 22
II 2 GD
ATEX / IECEx
IP66/67 – IK10

Set of two clamps for pole dia. 1.65”/42 mm to 2.36”/60 mm
(1-1/4" to 2"). Zinc plated steel or stainless steel.
95 for 1.25"/31.8 mm
or 1.50"/38.1mm
2.95”/
75.0 mm

0.55”/
14.0 mm

or 84 for 2.00"/50.8mm
1.25"/31.8 mm
or 1.50"/38.1mm

”/
36
2. m
Ø 0m
6

3.31”/
85 mm

0.55”/
14.0 mm

2.00"/50.8mm

1.65”/42 mm dia. galvanized steel wall mounting pole.

0.47”/
12.0 mm

Lighting

m

0.0 m

2”/43

16.9

Ø 0.79”/
20.0 mm

5.51”/140.0 mm

”/
1.65 m
m
42.0

0.20”/5.0 mm
mm
/75.0
2.95”

5.98”/152.0 mm
5.04”/128.0 mm

Lighting: Enclosed and Gasketed — Area — Fluorescent

Ø 0.41”/
10.5 mm

Set of two hinged brackets for adjusting luminaire.
Gray painted aluminum or stainless steel.
1.26”/
32.0 mm

0.22”/
5.5 mm

3
77 .03”
.0 /
mm

3
82 .23
.0 ”/
mm

0.71”/
18.0 mm

30
60
90

0
90

30°

1.61”/
41.0 mm

Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

0.57”/
14.5 mm

5.20”/132 mm

60

3.94”/
100.0 mm

30°
30

M8x1.25"/
31.8 mm
0.51”/
0.37”/
13.0 mm
9.5 mm

1093

FE Series Nonmetallic Fluorescent Luminaire Photometric Data

Standard and Emergency Battery Back-Up. Increased Safety

Longitudinal
Transverse

Polar curves for a 1000 lm flux, according to NF C 71-120
Luminaire symbol according to NF C 71-121
1 x 36 W
Efficiency 89.3%
NF C 71-121: 0.81 H + 0.08 T

1 x 18 Watt
TOTAL LUMINAIRE EFFICIENCY = 94.8%
NF C 71-121: 0.86 H + 0.09 T
Candela Distribution

Candela Distribution

0-180 90-270

0-180 90-270

Lighting

Candela Distribution
0-180 90-270

0

215

215

0

205

205

0

198

5

214 Degrees214

5

204 Degrees203

5

197Degrees 197

198

211

215

90°

10

202

203

90°

10

194

198

90°

15

207

213

75°

15

197

202

75°

15

190

197

75°

20

200

211

20

191

201

20

184

195

25

191

209

25

182

201

25

176

194

30

181

208

30

173

200

30

166

193

35

169

202

35

161

192

35

155

187

40

155

196

40

148

183

40

142

180

45

139

187

45

133

177

45

128

174

50

122

181

50

117

173

50

113

170

55

103

175

55

99

168

55

96

167

60

83

174

60

80

168

60

78

163

65

62

173

65

61

163

65

59

157

70

42

165

70

41

154

70

41

151

10

Lighting: Enclosed and Gasketed — Area — Fluorescent

1 x 58 W
Efficiency 87.5%
NF C 71-121: 0.80 H + 0.07 T

60°
45°

30°
0°	

15°

2 x 18 W
Efficiency 85.1%
NF C 71-121: 0.78 H + 0.08 T

0
5
10
15
20
25
30
35
40
45
50
55
60
65
70

90°
75°
60°
45°

30°
0°	

15°

3 x 18 W
Efficiency 68.1%
NF C 71-121: 0.63 G + 0.05 T

Candela Distribution
0-180 90-270
0
185 Degrees185
5
185
184
10
182
182
15
178
181
20
172
183
25
164
183
30
154
183
35
143
183
40
131
183
45
117
179
50
102
173
55
85
166
60
68
155
65
51
145
70
35
141

Candela Distribution

0-180 90-270
173 Degrees173
172
172
169
170
135
169
160
169
153
168
144
167
135
162
123
158
110
153
96
146
82
136
66
123
50
111
34
100

0-180 90-270
174 Degrees174
174
174
171
173
167
171
162
171
155
170
146
168
136
163
125
159
112
153
98
145
83
135
67
123
51
110
35
100

1094

30°
0°	

15°

90°
75°
60°
45°

30°
0°	

15°

0
5
10
15
20
25
30
35
40
45
50
55
60
65
70

60°
45°

30°
0°	

15°

2 x 58 W
Efficiency 76.9%
NF C 71-121: 0.70 H + 0.07 T

90°
75°
60°
45°

30°
0°	

15°

3 x 36 W
Efficiency 68.1%
NF C 71-121: 0.63 G + 0.07 T

Candela Distribution
0
5
10
15
20
25
30
35
40
45
50
55
60
65
70

45°

2 x 36 W
Efficiency 80.5%
NF C 71-121: 0.73 H + 0.07 T

Candela Distribution
0-180 90-270
195 Degrees195
195
194
192
192
187
192
181
193
173
194
163
194
152
193
138
192
124
191
108
183
91
176
73
163
55
150
37
145

60°

Candela Distribution
0-180 90-270
0
173Degrees 173
5
172
173
10
170
171
15
166
169
20
161
172
25
154
172
30
145
172
35
135
171
40
123
172
45
111
170
50
97
165
55
82
157
60
66
148
65
50
139
70
34
133

90°
75°
60°
45°

30°
0°	

15°

3 x 58 W
Efficiency 65.6%
NF C 71-121: 0.61 H + 0.04 T
Candela Distribution

90°
75°
60°
45°

30°
0°	

15°

0
5
10
15
20
25
30
35
40
45
50
55
60
65
70

0-180 90-270
170Degrees 170
170
170
167
168
163
169
158
167
151
167
143
163
133
159
122
155
109
149
95
140
81
129
65
116
49
105
33
96

90°
75°
60°
45°

30°
0°	

15°

Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

FL Series Light Duty Nonmetallic Fluorescent Luminaires

Standard and Emergency Back-Up. Zone 2 & 22
Zone 2 & 22
II 3 GD
ATEX - IEC IP65/67

Applications
•	 Light duty luminaire ideal for commercial and light industrial
locations including hazardous areas designated as Zone 2 or 	
22 environments.
•	 Typical applications include oil refineries petrochemical 	
plants, pulp and paper mills, tunnels and other light duty
manufacturing locations.

2 x 58 W

Features
•	
•	
•	
•	

Utilizes two 26 mm (T8) bi-pin fluorescent lamps.
Fiberglass reinforced polyester housing.
Instant start 95% power factor ballast.
Available in various lengths and wattages ranging from 18 to 58.
Pre-impregnated fiberglass reinforced white polyester housing.
•	 Closing system using stainless steel clips.
•	 Electrostatically applied white powder painted steel reflector
provides optimal lighting distribution.
•	 Poured-in-place elastomer gasket secures IP65 / 67 ingress
protection.

Standard Material
•	
•	
•	
•	
•	
•	

Options

Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

•	
	
•	
	

Certification Type: EFn (Standard Version) / EFn-EM
(Emergency Version
Zone 2
— Conforming to ATEX 94/9/CE: CE   II 3 G
	— ATEX/IEC Protection: Ex nR II or Ex nA II
	 — T Rating: T4 for nA protection mode.
See temperature chart for nR protection mode
•	 Zone 22
	 — Conforming to ATEX 94/9/CE: CE
II 3 D
	 — ATEX/IEC Protection: Ex tD A22
	 — Surface Temperature: (See table)
•	 Ambient Temperature: -4 °F to 131 °F / -20 °C to +55 °C
•	 CE Declaration of Conformity: 50213/50219
•	 ATEX Certificate: LCIE 08.6005X / LCIE 08.6063X
•	 IECEx Certificate: LCIE Ex 08.007X / LCIE Ex 08.008X
•	 Index of Protection (solid & liquid): IP65 / 67
•	 Time Before Opening: 10mn
•	 Ex Standards: EN / IEC 60079-15; 61241-0; 61241-1
•	 Product Standards: EN / IEC 60598-1; 60598-2-22
•	 EMC Standards: EN / IEC 55015; 61547
•	 Other Standards: EN / IEC 60529 (IP)

Lighting: Enclosed and Gasketed — Area — Fluorescent

•	 Available in 3 hours emergency version, including multi-tap
ballast with built-in monthly self test. Test results through multicolored LED.
•	 Plug-in battery pack is easy to remove for maintenance.
•	 Battery voltage is 6 volts and 4 Ah capacity.
•	 One fluorescent tube remains lit for up to 3 hours and up to 29%
light intensity for 18 Watt, 15% for 36 Watt and 9% for 58 Watt.
•	 All emergency units supplied with cut off switch to battery when
fixture is opened.

Certifications and Compliances

Lighting

Fiberglass reinforced polyester (FRP) housing
Polycarbonate lens
White powder painted sheet steel reflector
Elastomer gasket
Polycarbonate lampholders
Mounting accessories available in different materials such 	
as gray painted aluminum, zinc plated steel, galvanized steel 	
or 316 stainless steel

2 x18 W

1095

FL Series Light Duty Nonmetallic Fluorescent Luminaires

Standard and Emergency Back-Up. Zone 2 & 22
Zone 2 & 22
II 3 GD
ATEX - IEC IP65/67

Order using catalog numbering guide below or select catalog number from tables on following pages.
Catalog Numbering Guide For FN Non-Metallic Fluorescent Lighting Fixtures
FN

B

1

18

BU

Wattage:
18 - 18 Watt
36 - 36 Watt
58 - 58 Watt
55 - 55 Watt
80 - 80 Watt

Series:
FN - FN Series
Zone 2, 21 & 22
ATEX/IEC Certified

Lamp Type:
B - Bi-pin (G13)
C - PL Compact Lamps
(2G11) ②

A

C

Cable Type:
A - Armored M20
N - Unarmored M25
U - Unarmored M20

Voltage:
BU - 110 to 254 Vac/Vdc
50/60 Hz
BK - 220 to 240 Vac/Vdc
50/60 Hz

Options:
(Options must be listed
alphabetically)
C - Silicon Coating for
Diffuser
E - 3H Emergency
(combined) - Battery
6 V - 4 Ah
N - No Switch ③
X - 4 Entries ④

Mounting Version:
P - Pole Mount ①
S - Surface/Suspension Mount
Standard Wiring
T - Surface/Suspension Mount
Through Wiring
L - Surface/Suspension Mount
Dual Loop in/out Through
Wiring (single phase)

Lighting

Number of Lamps:
1 - Single
2 - Double
3 - Three Lamps

Lighting: Enclosed and Gasketed — Area — Fluorescent

P

Temperature Chart

Version
1 x 18 W
2 x 18 W
1 x 36 W
2 x 36 W
1 x 58 W
2 x 58 W

Dust
Surface
Temp.
167°F/75°C

181°F/83°C

196°F/91°C

T Rating for Ta =
104° F/40° C

Gas
T Rating for Ta =
122°F/50°C

T Rating for Ta =
131°F/55°C

T6

T6

T6

T6

T5

T5

T6

T6

T5

T6

T6

T5

T5

T5

T5

T5

T5

T5

① Only 2 x 18 W and 2 x 36 W with M25 entry versions.
② Only 55 W and 80 W standard versions.
③ Only for standard versions.
④ Only for S, T and L mounting versions.

1096

Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

FL Series Light Duty Nonmetallic Fluorescent Luminaires

Standard and Emergency Back-Up. Zone 2 & 22
Zone 2 & 22
II 3 GD
ATEX - IEC IP65/67

Standard Version for Armored and Unarmored Cable
Supplied with one M20 cable entry at each end plus two locknuts, two earth continuity and one blanking plug. 	
Also supplied with one 2 x (0.004 x 0.003 in2 / 3 x 2.5 mm2) max. flexible or rigid connection terminal block.
Number
of Lamps

Watts

Voltage
(V)

Weight
(lbs/kg)

Volume
(in3/dm3)

Pack.

Catalog
Number

1

18

220/240

5.07/2.3

1360.83/22.3

1

FLB118BKSA

2

18

220/240

5.07/2.3

1360.83/22.3

1

FLB218BKSA

2

18

110/254

5.07/2.3

1360.83/22.3

1

FLB218BUSA

1

36

220/240

6.17/2.8

2318.90/38

1

FLB136BKSA

1

36

110/254

6.17/2.8

2318.90/38

1

FLB136BUSA

2

36

220/240

7.94/3.6

2318.90/38

1

FLB236BKSA

2

36

110/254

7.94/3.6

2318.90/38

1

FLB236BUSA

1

58

220/240

7.50/3.4

2746.07/45

1

FLB158BKSA

1

58

110/254

7.50/3.4

2746.07/45

1

FLB158BUSA

2

58

220/240

9.70/4.4

2746.07/45

1

FLB258BKSA

2

58

110/254

9.70/4.4

2746.07/45

1

FLB258BUSA

Lighting

Emergency Version for Armored and Unarmored Cable
Supplied with one M20 entries with earth continuity at each end. Also supplied with two M20 locknuts and one blanking plug. 	
Equipped with one 2 x (0.008 x 0.003 in2 / 5 x 2.5 mm2) max. flexible or rigid connection terminal block
Watts

Voltage
(V)

Weight
(lbs/kg)

Volume
(in3/dm3)

Pack.

Catalog
Number

2

18

110/254

9.92/4.5

1360.83/22.3

1

FLB218BUSAE

2

36

110/254

15.43/7.0

2318.90/38

1

FLB236BUSAE

2

58

110/254

16.53/7.5

2746.07/45

1

FLB258BUSAE

Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

1097

Lighting: Enclosed and Gasketed — Area — Fluorescent

Number
of Lamps

FL Series Light Duty Nonmetallic Fluorescent Luminaire Accessories

Standard and Emergency Back-Up. Zone 2 & 22
Zone 2 & 22
II 3 GD
ATEX - IEC IP65/67

Description

Pack

Catalog Number

Fixing Brackets
Set of two brackets for surface installation
Zinc plated steel

1

FEFBZ

316 stainless steel

1

FEFBS

Aluminum (gray painted)

1

FESBA

316 stainless steel

1

FESBS

1

FERBM8Z

Brackets for Surface Mounting
Set of two

M8 Ring Bolts
Set of two
Zinc plated steel

Half Clamps Brackets for Pole Mounting
Set of two

Lighting

Dia. 1.65 to 1.93" / 42 to 49 mm pole (1.25 to 1.5" / 31.8 to 38.1 mm tube)
Zinc plated steel

1

FEHC49Z

316 stainless steel

1

FEHC49S

Zinc plated steel

1

FEHC60Z

316 stainless steel

1

FEHC60S

Aluminum

1

FEHBA

316 stainless steel

1

FEHBS

1.20 M stainless steel chain

1

FDSCS

Lighting: Enclosed and Gasketed — Area — Fluorescent

Dia. 2.36"/60 mm pole (2"/50.8mm tube)

Hinged Brackets
Set of two brackets for adjusting luminaire

Fall Prevention Kit

1098

Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

FL Series Light Duty Nonmetallic Fluorescent Luminaire Technical Data

Standard and Emergency Back-Up. Zone 2 & 22
Zone 2 & 22
II 3 GD
ATEX - IEC IP65/67

Emergency Function Diagram — Emergency Function 2 Tubes
Mains

Lighting Switch ON

Lighting Switch OFF

Fluorescent Luminaire ON

Fluorescent Luminaire OFF

Photometric Data
Longitudinal
Transverse

Polar curves for a 1000 lm flux, according to NF C 71-120
Luminaire symbol according to NF C 71-121
1 x 18 W
Efficiency 67.8%
NF C 71-121: 0.58 H + 0.09 T

2 x 18 W
Efficiency 68.9%
NF C 71-121: 0.60 H + 0.09 T

Candela Distribution
90-270

0

142

142

5

142

142

10

139

140

15

135

135

20

130

132

25

123

128

30

113

126

35

102

128

90

132

78

136

50

66

134

55

54

131

60

43

129

0-180
116

116

90°

5

115

119

10

113

133

75°

15

110

150

20

105

156

25

100

157

Degrees

60°
45°

30°

0°	

90-270

0

15°

30

94

158

35

88

159

40

81

158

45

74

157

50

65

152

55

55

145

60

45

137

65

33

119

65

35

128

70

23

110

70

25

114

2 x 36 W
Efficiency 64.1%
NF C 71-121: 0.57 H + 0.07 T

0
5
10
15
20
25
30
35
40
45
50
55
60
65
70

90°
75°
60°
45°

30°

0°	

15°

2 x 58 W
Efficiency 63.6%
NF C 71-121: 0.56 H + 0.07 T

Candela Distribution
0-180
163
162
160
155
149
142
132
120
104
80
60
50
40
31
23

Degrees

Lighting: Enclosed and Gasketed — Area — Fluorescent

40
45

Candela Distribution

Lighting

0-180

90-270
163
162
159
145
140
139
139
138
134
133
129
125
120
108
95

Candela Distribution
Degrees

90°
75°
60°
45°

30°

0°	

15°

Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

0
5
10
15
20
25
30
35
40
45
50
55
60
65
70

0-180
160
159
157
153
148
141
132
121
107
85
68
56
45
35
24

90-270
160
160
157
146
140
139
139
138
134
132
127
122
117
107
90

Degrees

90°
75°
60°
45°

30°

0°	

15°

1099

FN Series Heavy Duty Nonmetallic Fluorescent Luminaires

Standard and Emergency Back-Up. Zone 2 - 21 & 22
Zone 2 - 21 & 22
II 3 GD and II 2 D
ATEX / IECEx
IP66/67 - IK10

Applications
•	 Can be installed in hazardous areas designated as Zone 2, 	
21 and 22.
•	 For use in locations where a high degree of corrosion resistance
is required.
•	 For indoor/outdoor use where protection against dirt, water and
moisture is necessary.
•	 Typical applications include oil refineries, petrochemical
facilities, pulp and paper mills, food processing plants,
warehouses, underground tunnels and general 	
manufacturing facilities.

2 x 58 W

Lighting: Enclosed and Gasketed — Area — Fluorescent

Lighting

Features
•	 Corrosion-resistant fiberglass reinforced polyester body and
hinged polycarbonate lens.
•	 High impact resistance housing (20 Joules - IK10) from 	
-40° F to 131 °F / -40°C to 55 °C ambient temperature
and wind profile for use in extreme offshore and onshore
environments.
•	 Latch assembly and elastomer gasket seals against water and
dust ingress, IP66/67.
•	 Easily accessed for maintenance using Allen key or straight
blade screw driver.
•	 Central opening with unique patented release system to 	
prevent damage.
•	 Hinged parabolic reflector for high lumen output efficiency.
•	 Vibration resistant spring loaded lampholders for Bi-pin (G13) or
mono-pin (Fa6) versions.
•	 Electronic multi-tap ballast 110 to 254 Vac/Vdc +/- 10% 50/60
Hz, for global applications. High power factor electronic ballast
(>0.95). EOL (End Of Life) protection in accordance to the latest
EN/IEC 60079-7 standard.
•	 Also available with electronic ballast 220/240 Vac/Vdc +/- 10%
50/60 Hz. High power factor electronic ballast (>0.95). EOL.
•	 Available in 3 hours emergency version, including multi-tap
ballast with built-in monthly self test. Test results through 	
multi-color LED.

Standard Material
•	
•	
•	
•	
•	

Fiberglass reinforced polyester housing
Polycarbonate lens
Elastomer gasket
Highly reflective white polycarbonate internal reflector
Mounting accessories available in different materials such as
gray painted aluminum, zinc plated steel, galvanized steel or
316 stainless steel

Options
•	 Silicone coating for added protection in H2S hydrogen
sulfide environments.
•	 Without safety switch.
•	 Level gauge light fitting.
•	 316 stainless steel fixing inserts.

1100

2 x 36 W

2 x 18 W

Certifications and Compliances
•	
•	
	
	
	
•	
	
	
	
•	
•	
•	
•	
•	
•	
•	
•	
•	
•	
•	

Certification Type: FLd
Zone 2
— Conforming to ATEX 94/9/CE: CE
II 3 G
— ATEX/IEC Protection: Ex nR II or Ex nA II
— T Rating: T6 to T4
Zone 21 and 22
— Conforming to ATEX 94/9/CE: CE
II 2 D, CE
II 3 D
— ATEX/IEC Protection: Ex tD A21
— Surface Temperature: T167 °F/75 °C
Ambient Temperature: -40 °F to 131 °F / -40 °C to 55 °C
CE Declaration of Conformity: 50212/50225
ATEX Certificate: LCIE 03 ATEX 6072/6166
IECEx Certificate: IECEx LCI 04.0021
Other Certifications: GOST, Marine Listed UL 1598A
Index of Protection (solid & liquid): IP66/67
Impact Resistance (shock): IK10
Ex Standards: EN / IEC 60079-15; 61241-0; 61241-1
Product Standards: EN / IEC 60598-1; 60598-2-22
EMC Standards: EN / IEC 55015; 61547
Other Standards: EN / IEC 60529 (IP); 62262 (IK)

Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

FN Series Heavy Duty Nonmetallic Fluorescent Luminaires

Standard and Emergency Back-Up. Zone 2 - 21 & 22
Zone 2 - 21 & 22
II 3 GD and
II 2 D
ATEX / IECEx
IP66/67 - IK10

Order using catalog numbering guide below or select catalog number from tables on following pages.
Catalog Numbering Guide For FN Non-Metallic Fluorescent Lighting Fixtures
FN

B

1

18

BU

P

Wattage:
18 - 18 Watt
36 - 36 Watt
58 - 58 Watt
55 - 55 Watt
80 - 80 Watt

Series:
FN - FN Series
Zone 2, 21 & 22
ATEX/IEC Certified

Lamp Type:
B - Bi-pin (G13)
C - PL Compact Lamps
(2G11) ②

Number of Lamps:
1 - Single
2 - Double
3 - Three Lamps

A

C

Cable Type:
A - Armored M20
N - Unarmored M25
U - Unarmored M20

Voltage:
BU - 110 to 254 Vac/Vdc
50/60 Hz
BK - 220 to 240 Vac/Vdc
50/60 Hz

Options:
(Options must be listed
alphabetically)
C - Silicon Coating for
Diffuser
E - 3H Emergency
(combined) - Battery
6 V - 4 Ah
N - No Switch ③
X - 4 Entries ④

Lighting

Mounting Version:
P - Pole Mount ①
S - Surface/Suspension Mount
Standard Wiring
T - Surface/Suspension Mount
Through Wiring
L - Surface/Suspension Mount
Dual Loop in/out Through
Wiring (single phase)

Lighting: Enclosed and Gasketed — Area — Fluorescent

① Only 2 x 18 W and 2 x 36 W with M25 entry versions.
② Only 55 W and 80 W standard versions.
③ Only for standard versions.
④ Only for S, T and L mounting versions.
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

1101

FN Series Heavy Duty Nonmetallic Fluorescent Luminaires

Standard and Emergency Back-Up. Zone 2 - 21 & 22
Zone 2 - 21 & 22
II 3 GD and II 2 D
ATEX / IECEx
IP66/67 - IK10

Standard Version
Surface/Suspension Mounting and Standard Wiring
Version
Connection via 1 x 6 terminals.
Capacity (flexible/solid): 0.006 in2/0.009 in2 / 4 mm2/6 mm2.
Unarmored Version - Bi-pin (G13)
Three M25 threaded entries, two at one end and one at opposite end, supplied with one 	
M25 polyamide cable gland (dia. 0.31 to 0.73" / 8 to 18.5 mm) and two M25 polyamide blanking plugs.
Catalog
Number
FNB218BKSNN
FNB218BUSNN
FNB236BKSNN
FNB236BUSNN
FNB258BKSNN
FNB258BUSNN

Lighting

Number
Power
Lamp
Voltage
Weight
Volume
of Lamps
(W)
Type
(V)
(lbs/kg)
(in3/dm3)
2
18
G13
220/240
12.13/5.5
1971.07/32.3
2
18
G13
110/254
12.13/5.5
1971.07/32.3
2
36
G13
220/240
17.42/7.9
3307.49/54.2
2
36
G13
110/254
17.42/7.9
3307.49/54.2
2
58
G13
220/240
19.84/9
3966.54/65
2
58
G13
110/254
11
3966.54/65
Armored Version - Bi-pin (G13)
Two M20 threaded entries with brass earth continuity plate at one end and 	
one M20 plugged clearance entry, supplied with two M20 polyamide plugs.
Number
of Lamps
2
2
2
2
2
2

Power
(W)
18
18
36
36
58
58

Lamp
Type
G13
G13
G13
G13
G13
G13

Voltage
(V)
220/240
110/254
220/240
110/254
220/240
110/254

Weight
(lbs/kg)
12.13/5.5
12.13/5.5
17.42/7.9
17.42/7.9
19.84/9
24.25/11

Volume
(in3/dm3)
1971.07/32.3
1971.07/32.3
3307.49/54.2
3307.49/54.2
3966.54/65
3966.54/65

Catalog
Number
FNB218BKSAN
FNB218BUSAN
FNB236BKSAN
FNB236BUSAN
FNB258BKSAN
FNB258BUSAN

Lighting: Enclosed and Gasketed — Area — Fluorescent

Emergency Version
Surface/Suspension Mounting and Standard Wiring
Connection via 1 x 4 terminals for 18 W version.
Connection via 1 x 8 terminals for 36 W & 58 W
versions.
Capacity (flexible/solid): 4 mm2/6 mm2.

18 W

36/58 W

Unarmored Version - Bi-pin (G13)
Three M25 entries, two at one end and one at opposite end, supplied with
one M25 polyamide cable gland (dia. 0.31 to 0.73" / 8 to 18.5 mm) and two
M25 polyamide blanking plugs.
Number
Power
Lamp
Voltage
Weight
Volume
of Lamps
(W)
Type
(V)
(lbs/kg)
(in3/dm3)
2
18
G13
110/254
16.09/7.3
1971.07/32.3
2
36
G13
110/254
21.16/9.6
3307.49/54.2
2
58
G13
110/254
23.59/10.7
3966.54/65
Armored Version - Bi-pin (G13)
Two M20 threaded entries with brass earth continuity plate at one end and 	
one M20 plugged clearance entry, supplied with two M20 polyamide plugs.
Number
of Lamps
2
2
2

1102

Power
(W)
18
36
58

Lamp
Type
G13
G13
G13

Voltage
(V)
110/254
110/254
110/254

Weight
(lbs/kg)
16.09/7.3
21.16/9.6
23.59/10.7

Volume
(in3/dm3)
1971.07/32.3
3307.49/54.2
3966.54/65

Duration
(Hours)
3H
3H
3H

Battery
Capacity
4 Ah
4 Ah
4 Ah

Catalog
Number
FNB218BUSNEN
FNB236BUSNEN
FNB258BUSNEN

Duration
(Hours)
3H
3H
3H

Battery
Capacity
4 Ah
4 Ah
4 Ah

Catalog
Number
FNB218BUSAEN
FNB236BUSAEN
FNB258BUSAEN

Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

FN Series Heavy Duty Nonmetallic Fluorescent Luminaire Accessories

Standard and Emergency Back-Up. Zone 2 - 21 & 22
Zone 2 - 21 & 22
II 3 GD and II 2 D
ATEX / IECEx
IP66/67 - IK10

Description

Pack

Catalog Number

Fixing Brackets
Set of two brackets for surface installation
Zinc plated steel

1

FEFBZ

316 stainless steel

1

FEFBS

Aluminum (gray painted)

1

FESBA

316 stainless steel

1

FESBS

1

FERBM8Z

Brackets for Surface Mounting
Set of two

M8 Ring Bolts
Set of two
Zinc plated steel

Half Clamps Brackets for Pole Mounting
Set of two
Dia. 1.65 to 1.93" / 42 to 49 mm pole (1.25 to 1.5" / 31.8 to 38.1 mm tube)
1

FEHC49Z

316 stainless steel

1

FEHC49S

Zinc plated steel

1

FEHC60Z

316 stainless steel

1

FEHC60S

1

FEWMG

Aluminum

1

FEHBA

316 stainless steel

1

FEHBS

Lighting

Zinc plated steel

Dia. 2.36"/60 mm pole (2"/50.8mm tube)

Lighting: Enclosed and Gasketed — Area — Fluorescent

Wall Mounting Adaptor
For pole mounting version (dia. 1.65"/42 mm)
Galvanized steel
Hinged Brackets
Set of two brackets for adjusting luminaire

Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

1103

FN Series Heavy Duty Nonmetallic Fluorescent Luminaire Technical Data

Standard and Emergency Back-Up. Zone 2 - 21 & 22
Zone 2 - 21 & 22
II 3 GD and II 2 D
ATEX / IECEx
IP66/67 - IK10

Wiring Diagram

Emergency Function Diagram
Two Lamp Version

Mains
PE	

N	

Mains

L
Lighting
Switch

Lighting Switch ON

Lighting Switch OFF

Lighting Switch ON

Lighting Switch OFF

ON

L’

U
N
PE

OFF

Standard Fluorescent
Lighting Fixture

Three Lamp Version
Mains

U’
U
N
PE

ON
Emergency Fluorescent
Lighting Fixture

Lighting

OFF

LED Status
Color

Indication

Green

Lighting: Enclosed and Gasketed — Area — Fluorescent

Function

LED glows

Batteries are connected

LED blinks

Batteries are charged

Red

LED blinks

Batteries are not connected or defect

Yellow

LED blinks

Batteries are charging and discharging during automatic cycle

Dimensions
Surface/Suspension Mounting
18 W

36 W
2 X MB

15.75"/
400 mm

27.56"/ 700.0 mm

30.91"/785.0mm

2 X MB

54.72"/ 1390.0 mm

5.71"/
145.0 mm

58 W

27.56"/ 700.0 mm

2 X MB

66.54"/ 1690.0 mm
8.54"/
217.0 mm

1104

Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

FN Series Heavy Duty Nonmetallic Fluorescent Luminaire Photometric Data

Standard and Emergency Back-Up. Zone 2 - 21 & 22

Longitudinal
Transverse

Polar curves for a 1000 lm flux, according to NF C 71-120
Luminaire symbol according to NF C 71-121
2 x 18 W
Efficiency 85.1%
NF C 71-121: 0.78 H + 0.08 T

2 x 36 W
Efficiency 80.5%
NF C 71-121: 0.73 H + 0.07 T

Candela Distribution

Candela Distribution

0-180 90-270

0-180 90-270

0

195

195

0

185

5

195

194

5

185

10

192

192

90°

10

182

15

187

192

75°

15

20

181

193

25

173

194

60°

30

163

194

45°

35

152

193

40

138

45

124

50

108

182

55

91

176

60

73

163

65

55

70

37

Degrees

2 x 58 W
Efficiency 76.9%
NF C 71-121: 0.70 H + 0.07 T
Candela Distribution
0-180 90-270

185

0

173

184

5

172

Degrees

173
173

Degrees

182

90°

10

170

171

90°

178

181

75°

15

166

169

75°

20

172

183

20

161

172

25

164

183

25

154

172

30

154

183

30

145

172

35

143

183

35

135

171

192

40

131

183

40

123

172

191

45

117

179

45

111

170

50

102

173

50

97

165

55

85

166

55

82

157

60

68

155

60

66

148

150

65

51

145

65

50

139

145

70

35

141

70

34

133

30°
0°	

15°

60°
45°

30°
0°	

15°

60°
45°

30°
0°	

15°

Lighting

Lighting: Enclosed and Gasketed — Area — Fluorescent

Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

1105

RigMaster™ Metallic Fluorescent Luminaires

For Hazardous and Adverse Locations

Suitable for Use in Wet Locations. 32 W, 40 W and 60 W Two-Lamp Fixtures.
Class I, Division 2, Groups A, B, C, D
NEMA Type 4X
Marine Type Electric Fixture Non-Recessed
Outside Type (Salt Water) ①②

Applications
•	 Enclosed and gasketed fixtures for use where vapors, moisture,
dirt or corrosive atmospheres are encountered.
•	 For use in hazardous locations defined by the NEC as Class
I, Division 2. Groups A, B, C & D; Marine Type Electric Fixture
Non-Recessed Outside Type (Salt Water); UL1598A; and 	
Type 4X.
•	 For use in locations where a high degree of corrosion resistance
is required.
•	 For indoor/outdoor use where protection against dirt, water and
moisture is necessary.
•	 Typical applications include:
	 — Oil drilling rigs
	 — Marine loading terminals
	 — Processing plants
	 — Pipeline pumping stations
	 — Water treatment plants
	 — Lubrication pits

RM2232BUSW

Illustrated Feature

Lighting: Enclosed and Gasketed — Area — Fluorescent

Lighting

Features
•	 Choice of mountings: end brackets, swivel brackets and straight
brackets.
•	 Thick 1/8” clear acrylic lens protects against possible broken
glass from lamps.
•	 RigMaster fixtures are supplied with the following ballast
options:
— Class P low energy (E) ballasts, equipped with an automatic
thermally-activated protective device. They offer protection
against excessive voltage, internal ballast short circuiting,
inadequate lamp maintenance and improper fixture
application.
— 220- and 240-volt options in both 50 and 60 Hz.
•	 High-temperature nickel-cadmium battery has a life expectancy
of 7 to 10 years.
•	 Battery charger indicator light and test switch are mounted
inside the enclosure and visible through the clear lens.
•	 Heavy-duty telescoping lampholders.
•	 Fixtures are shipped complete with lamps.
•	 Swivel End Mount fixture comes standard with eyebolt on fixture
end for connecting safety cable.
•	 Swivel Center Mount and Straight Center Mount fixtures come
standard with cast mounts on fixture end for connecting safety
cable.

Four plated steel latches on each side of door assure
integrity of fixture for areas as classified.

Certifications and Compliances
•	 UL Standard: UL 1598, UL 844, UL 924
•	 UL Listed: E10794

Standard Materials
•	
•	
•	
•	
•	

Reflector housings: extruded aluminum
Door frame: 1/8” extruded aluminum
Door clamps: heavy-duty plated spring steel
Lampholders: white urea plastic
Gasket: neoprene

Options
•	 Individually fused ballast: suffix –F.
•	 Emergency battery pack: suffix –EL ①.
•	 Emergency Battery Pack capability in moments of power
interruption. Luminaire automatically switches to emergency
mode, keeping one lamp illuminated for a minimum of 90
minutes. When AC power is restored, battery automatically
recharges in 24 hours. Initial light output is 600-700 lumens.

① Fixtures with emergency ballast are not recommended where the ambient temperature may fall below 32 °F/0 °C for extended periods.
② Does not apply to fixtures with fusing.

1106

Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

RigMaster™ Metallic Fluorescent Luminaires
For Hazardous and Adverse Locations

Suitable for Use in Wet Locations. 32 W, 40 W and 60 W Two-Lamp Fixtures.
Class I, Division 2, Groups A, B, C, D
NEMA Type 4X
Marine Type Electric Fixture Non-Recessed
Outside Type (Salt Water) ①②

Order using catalog numbering guide below or select catalog number from tables on following pages.
Catalog Numbering Guide For RigMaster Metallic Fluorescent Lighting Fixtures
RM

2

2

Series:
RM - RigMaster
Metallic

40

12

SS

Lamp Type:
32 - 32 W, T8
(Electronic)
40 - 40 W, (Electronic)
60 - 60 W, T12, HO
800 MA (48) ⑤

Hazardous Rating: 	
Class I, Division 2

CB

EL

Mounting:
CB- End
SW- Swivel
ST- Fixed

Options:
EL- Emergency 	
Battery Pack ③
F- Fuse	 	

Voltage ④:
12 - 120 V (40 W, T12)
27 - 277 V (40 W, T12)
BU - 120-277 V, 50/60 Hz 	
(32 W, T8; 60 W, T12)

Number of Lamps:
2 - Two Lamps

Ballast Type:
SS- Solid State (40W, T12,
Electronic) Only

Lamp

Lighting

Thermal Performance RigMaster Fixtures

Quantity

Watt

Type

Ambient Temp
(°F/°C)

“T”
Numbers

Hazardous
Classification

RM2232

2

32

265MA-RS

104/40

T-4

Class I, Division 2, Groups A, B, C, D

RM2240

2

40

430MA-RS

104/40

T-4

Class I, Division 2, Groups A, B, C, D

RM2260

2

60

800MA-HO

104/40

T-4

Class I, Division 2, Groups A, B, C, D

① Fixtures with emergency ballast are not recommended where the ambient temperature may fall below 32 °F/0 °C for extended periods.
② Does not apply to fixtures with fusing.
③ For 50 Hz with Emergency Battery Pack, consult factory for certification.
④ BU for 32 W, T8 and 60 W, T12 only. Voltage must be specified for 40 W, T12.
⑤ CW suffix not needed for 60 W since -20 °F/-28 °C starting provided as a standard.
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

1107

Lighting: Enclosed and Gasketed — Area — Fluorescent

Fixture

RigMaster™ Metallic Fluorescent Luminaires

For Hazardous and Adverse Locations

Suitable for Use in Wet Locations. 32 W, 40 W and 60 W Two-Lamp Fixtures.
Class I, Division 2, Groups A, B, C, D
NEMA Type 4X
Marine Type Electric Fixture Non-Recessed
Outside Type (Salt Water) ①②

Swivel End Bracket

Swivel Center Bracket

Straight Center Bracket

No. of
Lamps ③

Lamp
Wattage

Lamp
Type

Volts

Bracket
Type

Catalog
Number

2

32

T8

120-277 V, 50/60 Hz

end

RM2232BUCB

2

40

T12

120 V, 60 Hz

end

RM224012SSCB

2

40

T12

277 V, 60 Hz

end

RM224027SSCB

2

60

T12

120-277 V, 50/60 Hz

end

RM2260BUCB

2

32

T8

120-277 V, 50/60 Hz

swivel

RM2232BUSW

2

40

T12

120 V, 60 Hz

swivel

RM224012SSSW

2

40

T12

277 V, 60 Hz

swivel

RM224027SSSW

2

60

T12

120-277 V, 50/60 Hz

swivel

RM2260BUSW

2

32

T8

120-277 V, 50/60 Hz

straight

RM2232BUST

2

40

T12

120 V, 60 Hz

straight

RM224012SSST

2

40

T12

277 V, 60 Hz

straight

RM224027SSST

2

60

T12

120-277 V, 50/60 Hz

straight

RM2260BUST

Replacement Parts
Lighting

Description

Catalog Number

Lens
Lens and Frame Assembly

RIGLENS

Straight Bracket

RM3002SEM

Angle Bracket

RM3002AEM

Swivel Bracket

RMBMSW

Back-Straight Bracket

RMBMST

60 W Spring Loaded

RM60SRS

60 W Fixed Replacement

RM60FRS

32 W Replacement

RM32RS

Lighting: Enclosed and Gasketed — Area — Fluorescent

Mounting Brackets

Sockets

Mounting Accessories — Safety Cable
Galvanized Steel Cable

Catalog Number

Stainless Steel Cable

Catalog Number

3 ft/0.9 m

RMSC3GASL

3 ft/0.9 m

RMSC3STSL

4 ft/1.2 m

RMSC4GASL

4 ft/1.2 m

RMSC4STSL

Connecting Safety Cable

Swivel Center Mount and Straight Center
Mount fixture comes standard with cast
mounts on fixture end for connecting
safety cable.

Swivel End Mount fixture comes standard with
eyebolt on fixture end for connecting safety
cable.

① Fixtures with emergency ballast are not recommended where the ambient temperature may fall below 32 °F/0 °C for extended periods.
② Does not apply to fixtures with fusing.
③ Fixtures shipped complete with lamps.

1108

Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

RigMaster™ Metallic Fluorescent Luminaire Dimensions
For Hazardous and Adverse Locations

Suitable for Use in Wet Locations. 32 W, 40 W and 60 W Two-Lamp Fixtures.

End Bracket Mounting

.8

01

.25

3
"/1

51

8.10"/
205.7 mm

mm
m

m
.8
93
11 o C
/
"
.0 C t
47

8.10"/205.7 mm
5.42"/137.7 mm

Swivel Bracket Mounting
2.00"/50.8 mm
"/
.50 m
12
m
.5
7
31

Ø 0.28"/
7.0 mm

Lighting

9.75"/
247.7 mm

10.35"/
262.9 mm

Lighting: Enclosed and Gasketed — Area — Fluorescent

17.6"/447.0 mm

Straight Bracket Mounting
/
.0"
11 .4 mm
9
27

6.75"/
171.5 mm

Fixture Bracket Type

Weight in Lbs/Kgs

End

35/15.9

Swivel

35/15.9

Straight

35/15.9

Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

1109

RigMaster™ Metallic Fluorescent Luminaire Photometrics
For Hazardous and Adverse Locations

Suitable for Use in Wet Locations. 32 W, 40 W and 60 W Two-Lamp Fixtures.

CATALOG NUMBER: RM2232BU

Candela Distribution

25 1106 1110 1109 1110 1106 512

Luminaire: Class I, Division 2 fluorescent fixture with glass lens (4 foot, T-8. 32 Watt) tested at
120 V
Lamps: Two Phillips 32 W, 4-foot F32T8/TL741fluorescents
Ballast: Advance T-8, 32 Watt, catalog number ICN-2P32-SC 50/60 Hz, Instant Start, 120-277 V
Ambient Temperature: 24 °C/75 °F
Mounting: With Bracket
Based on: 2,850 Lumens per Lamp
TOTAL LUMINAIRE EFFICIENCY = 57.6%

0.0

22.5 45.0 67.5 90.0 Flux

0 1234 1234 1234 1234 1234
5 1234 1228 1227 1228 1224 117
15 1183 1187 1185 1187 1183 335

35

984 990 996 990 984 620

45

813 823 830 823 813 634

CIE Type – Direct

55

612 619 614 619 612 550

Plane:

65

364 375 381 375 364 368

75

124 126 112 126 124 133

85

9

7

7

7

90

1

1

1

1

9

0 1132 1132 1132 1132 1132

Lighting

5 1124 1128 1126 1128 1124 107

Lighting: Enclosed and Gasketed — Area — Fluorescent

% FIXT.

90˚

0- 30

964

16.9

29.4

Spacing Criteria:

1.3

1.3

0- 40

1584

27.8

48.3

Shielding Angles:

1.0

0.0

0- 60

2767

48.6

84.3

0- 90

3281

57.6

100.0

90-180

0

0.0

0.0

0-180

3281

57.6

100.0

CATALOG NUMBER: RM2232BU

22.5 45.0 67.5 90.0 Flux

15 1085 1089 1090 1089 1085 308
25 1003 1010 1011 1010 1003 465

Luminaire: Class I, Division 2 fluorescent fixture with glass lens (4 foot, T-12. 34 Watt) tested at
120 V
Lamps: 2 Philips 34 Watt (4 foot, T-12) F4OCW/RS/EW
Ballast: Advance T-12, 34 Watt, catalog number REL-2S40-SC 50/60 Hz, Instant Start, 120 V
Ambient Temperature: 24 °C/75 °F
Mounting: With Bracket
Based on: 2,650 Lumens per Lamp

35

882 889 888 889 882 555

45

726 730 726 730 726 561

CIE Type – Direct

55

535 535 533 535 535 477

Plane:

65

322 316 311 316 322 314

75

121 112 104 112 121 121

85

9

7

6

7

9

90

0

0

0

0

0

TOTAL LUMINAIRE EFFICIENCY = 55.1%

ZONAL LUMEN SUMMARY
ZONE LUMENS % LAMP

Spacing Criteria:

% FIXT.

0˚

90˚

0- 30

880

16.6

30.1

1.2

1.2

0- 40

1435

27.1

49.2

11

Candela Distribution
0.0

ZONE LUMENS % LAMP
0˚

12

Candela Distribution
0.0

ZONAL LUMEN SUMMARY

0- 60

2473

46.7

84.7

0- 90

2919

55.1

100.0

90-180

0

0.0

0.0

0-180

2919

55.1

100.0

CATALOG NUMBER: RM2260BU

22.5 45.0 67.5 90.0 Flux

25 1100 1108 1111 1108 1100 511

Luminaire: Class I, Division 2 fluorescent fixture with glass lens (4 foot, T-12. 60 Watt) tested
Lamps: 2 Philips 60 Watt (4 foot, T-12) F48T12CWHO ALTO
Ballast: Advance T-12, 60 Watt, catalog number VEL-2S110
Ambient Temperature: 24 °C/75 °F
Mounting: With Bracket
Based on: 4,050 Lumens per Lamp

35

TOTAL LUMINAIRE EFFICIENCY = 39.6%

0 1237 1237 1237 1237 1237
5 1227 1231 1229 1231 1227 117
15 1188 1194 1193 1194 1188 337

968 977 976 977 968 610

45

800 806 805 806 800 619

CIE Type – Direct

55

591 593 594 593 591 529

Plane:

65

351 352 351 352 351 347

Spacing Criteria:

75

122 116 106 116 122 127

85

10

8

6

8

10

90

0

0

0

0

0

1110

12

ZONAL LUMEN SUMMARY
ZONE LUMENS % LAMP

0˚

90˚

1.2

1.2

0- 30

965

11.9

% FIXT.
30.1

0- 40

1574

19.4

49.1

0- 60

2722

33.6

84.8
100.0

0- 90

3208

39.6

90-180

0

0.0

0.0

0-180

3208

39.6

100.0

Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

RigMaster™ 304 Stainless Steel Fluorescent Luminaires V

CSA Certification Only. Enclosed and Gasketed. For Hazardous and Adverse Locations
Suitable for use in Wet or Marine (Salt Water) Locations. 32 W, 40 W and 60 W Two-Lamp Fixtures.
Class I, Division 2, Groups A, B, C, D
Class II, Division 1 and 2, Groups E, F, G
Class III
CSA Enclosure 3

Applications
•	 Appleton Rigmaster is designed for the requirements of the oil
drilling industry.
•	 For use on seashore, offshore or land based drilling rigs.
•	 Suitable for industrial applications requiring a highly corrosionresistant fluorescent fixture.
•	 Approved for outdoor use.
•	 Ideal for shipboard use. (Salt water environment).
•	 For use in high vibration installations.
•	 Can be installed to illuminate work areas, stairways and ladders,
pumps and instrument panels, chemical plants and refineries or
for shipboard deck lighting.

Features
Standard Materials
•	 Fixture body, snap clips, hardware, lens frame: 304 stainless
steel
•	 Mounting brackets, CG connectors, reflector: copperfree (4/10
of 1% max.) aluminum

Standard Finishes
•	 All components have a natural finish

Options
•	 Emergency battery, operates lamps at 60% for 90 minutes
during power outages, suffix -E.
•	 Fabricated from 316 stainless steel, suffix -316.
•	 60 Watt high output ballast available (-20 °F/-29 °C starting
temperature).
•	 Lens: tempered glass, suffix -GN.

Compliances
•	 CSA Standard: C22.2 No. 250, C22.2 No. 137
•	 CSA Certified: 025428

2

4

Series:
ARM - RigMaster
Stainless Steel

A

BU

GN

Cable Entry	
Jacket Range:
A - .312”to .437”
B - .375” to .500”
C - .500" to .625"
Number of Lamps:
2 - Two Lamps

Voltage:
BU - 120-277 V 50/60 Hz
A5 - 347 V 60 Hz

Lamp Type: ①
32 - 32 W, T8 (Electronic)
40 - 40 W, T12 (Rapid Start)
60 - 60 W, T12 (High Output)

Factory Installed Options:
EL- Emergency Back-up Battery
316 - 316 Stainless Steel
GN - Tempered Glass Lens

① Lamps not furnished with fixture.
V CSA Certification Only.
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

1111

Lighting: Enclosed and Gasketed — Area — Fluorescent

Order using catalog numbering guide below or select catalog number from tables on following pages.
Catalog Numbering Guide For RigMaster Stainless Steel Fluorescent Lighting Fixtures — Bracket Mounted
ARM

Lighting

•	 Corrosion-resistant durable seam welded 304 stainless steel
construction.
•	 Vibration resistant – spring loaded sockets hold lamps securely
with maximum shock and vibration protection.
•	 Positive seal lens assembly provides a secure gasketed seal
around the lens. Lexan, impact resistant lens is standard.
•	 CG series watertight cord connectors grip the cable securely at
the point of entrance to prevent insulation wear and strain on
connections made within the enclosure. CG connectors seal out
oil, water and other harmful atmospheres containing moisture to
keep the enclosure clean and dry.
•	 Stainless steel snap action clips permit relamping without tools.
Three clips serve as hinges allowing unobstructed access to the
fixture interior.
•	 The highly polished finished reflector has excellent light
distribution and high efficiency.
•	 Access to the ballast and wiring chamber is quick and easy,
requiring the removal of two screws.
•	 Rigmasters are provided with feed-thru wiring, eliminating the
need for a junction box.

RigMaster™ 304 Stainless Steel Fluorescent Luminaires V

CSA Certification Only. Enclosed and Gasketed. For Hazardous and Adverse Locations
Suitable for use in Wet or Marine (Salt Water) Locations. 32 W, 40 W and 60 W Two-Lamp Fixtures.
Class I, Division 2, Groups A, B, C, D
Class II, Division 1 and 2, Groups E, F, G
Class III
CSA Enclosure 3

No. of
Lamps ①

Lamp
Wattage

Lamp
Type

Volts

Operating
Amps

Input
Watts

Cable
Range

Catalog
Number

59 - 55

.312-.437

ARM232ABU

Rapid Start — 48” — T8 — Minimum Starting Temperature 0 °F/-18 °C
2

32

T8

120-277 V

0.49 - 0.19

2

32

T8

347 V

0.21

62

.312-.437

ARM232AA5

2

32

T8

120-277 V

0.49 - 0.19

59 - 55

.375-.500

ARM232BBU

2

32

T8

347 V

0.21

62

.375-.500

ARM232BA5

2

32

T8

120-277 V

0.49 - 0.19

59 - 55

.500-.625

ARM232CBU

2

32

T8

347 V

0.21

62

.500-.625

ARM232CA5

Rapid Start — 48” — F48T12/CW — Minimum Starting Temperature -22 °F/-30 °C
2

40

T12

120-277 V

0.7 - 0.26

84 - 70

.312-.437

ARM240ABU

2

40

T12

347 V

0.28

96

.312-.437

ARM240AA5

2

40

T12

120-277 V

0.7 - 0.26

84 - 70

.375-.500

ARM240BBU

2

40

T12

347 V

0.28

96

.375-.500

ARM240BA5

2

40

T12

120-277 V

0.7 - 0.26

84 - 70

.500-.625

ARM240CBU

2

40

T12

347 V

0.28

96

.500-.625

ARM240CA5

122 - 108

.312-.437

ARM260ABU

Lighting: Enclosed and Gasketed — Area — Fluorescent

Lighting

Rapid Start — 48” — 800 mA — F48T12/CW/HO — Minimum Starting Temperature -22 °F/-30 °C
2

60

T12

120-277 V

1.05 - 0.40

2

60

T12

347 V

0.45

144

.312-.437

ARM260AA5

2

60

T12

120-277 V

1.05 - 0.40

122 - 108

.375-.500

ARM260BBU

2

60

T12

347 V

0.45

144

.375-.500

ARM260BA5

2

60

T12

120-277 V

1.05 - 0.40

122 - 108

.500-.625

ARM260CBU

2

60

T12

347 V

0.45

144

.500-.625

ARM260CA5

Dimensions in Inches/Millimeters

① Lamps not furnished with fixture.
V CSA Certification Only.

1112

Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

VRS™ and DRS™ Fluorescent Luminaires

Enclosed and Gasketed. Suitable for Use in Wet Locations
32 W, 40 W and 60 W Two- and Three-Lamp Fixtures.
VRS:
Class I, Division 2, Groups A, B, C, D

DRS:
Class II, Division 1 and 2, Groups F, G
Class III

Applications
•	 VRS
	 — Enclosed and gasketed fixtures for use where vapors, 	
moisture, dirt or corrosive atmospheres are encountered.
	 — Corrosion-resistant polyester powder coating protects 	
against corrosive atmospheres.
•	 DRS
	 — Dust-ignitionproof fixtures for use where ignitable amounts 	
of dust are present from handling such products as grain,
flour, sugar, starch and textiles.
	 — Suitable for use in Class II and III, Division 1, classified areas.
	 — Corrosion-resistant finish prolongs fixture life and retains 	
fixtures reflectivity longer.

Features
VRS Enclosed and Gasketed DRS Dust-Ignition Proof

Illustrated Features

Lighting

Three plated steel latches on each side of door
assure integrity of fixture for areas as classified.

Lighting: Enclosed and Gasketed — Area — Fluorescent

•	 Choice of mountings: pendant and feed thru are standard, 	
angle bars for chain suspension, or angle brackets (up to 45°)
for wall or ceiling mounting.
•	 Thick 1/4” clear tempered glass lens protects against possible
broken glass from lamps.
•	 VRS and DRS fixtures are supplied with the following 	
ballast options:
— Class P low energy (E) ballasts, equipped with an automatic
thermally activated protective device. They offer protection
against excessive voltage, internal ballast short circuiting,
inadequate lamp maintenance and improper fixture
application
•	 High-temperature nickel cadmium battery has a life expectancy
of 7 to 10 years.
•	 Battery charger indicator light and test switch are mounted
inside the enclosure and visible through the clear lens.
•	 Heavy duty telescoping lampholders.
•	 Low operating cost provides more lumens per Watt than
incandescent.
•	 Easy cleaning one-piece, seamless welded construction virtually
eliminates dust and moisture accumulation.

Standard Materials
•	
•	
•	
•	
•	
•	

Reflector housings: 20-gauge steel
Door frame: 16 gauge steel with clear glass
Door clamps: heavy-duty plated spring steel
Suspension hubs: 1/2” die-cast aluminum
Lampholders: white urea plastic
Gaskets: VRS – neoprene; DRS – fiberglass

Standard Finishes
•	 Reflector housings: VRS – white polyester powder coating; DRS
– white polyester powder coating
•	 Door frame: zinc electroplate
•	 Door clamps, suspension hubs and lampholders: natural finish

Options
•	 Individually fused ballast. Suffix -F.
•	 Emergency battery pack, Suffix -EL ➊.
•	 Emergency battery pack capability in moments of power
interruption. Luminaire automatically switches to emergency
mode, keeping one lamp illuminated for a minimum of 90
minutes. When AC power is restored, battery automatically
recharges in 24 hours. Initial light output is 600-700 lumens.

Pan mounted ballast and sockets with safety
chain provide quick, safe maintenance.

Certifications and Compliances

•	 UL Standard: UL 1598, UL 844
•	 UL Listed: E10794

➊ Fixtures with emergency ballast are not recommended where the ambient temperature may fall below 32 °F/0 °C for extended periods.
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

1113

VRS™ and DRS™ Fluorescent Luminaires

Enclosed and Gasketed. Suitable for Use in Wet Locations
32 W, 40 W and 60 W Two- and Three-Lamp Fixtures.
VRS:
Class I, Division 2, Groups A, B, C, D

DRS:
Class II, Division 1 and 2, Groups F, G
Class III

Order using catalog numbering guide below or select catalog number from tables on following pages.
Catalog Numbering Guide For VRS And DRS Non-Metallic Fluorescent Lighting Fixtures
VRS

2

40

Series:
VRS - Vaportight
DRS - Dust-Ignitionproof

BU

Lamp Type:
32 - 32 W,T8 (Electronic)
40 - 40 W, (Electronic)
60 - 60 W, T12, HO 800 MA (48)

Number of Lamps
2 - 2 Lamps
3 - 3 Lamps

EL
Options:
EL - Emergency Battery Pack
F - Fuse

Voltage:
BU -  120-277 V, 50/60 Hz	
347 - 347 V 60 Hz V

Technical Data: Thermal Performance of VRS and DRS Fixtures

Lighting: Enclosed and Gasketed — Area — Fluorescent

Lighting

Lamp
Fixture

Quantity

Watt

Type

Ambient
Temp °F/°C

“T”
Numbers

Hazardous
Classification

VRS232

2

32

265MA-RS

104/40

T-4A

Class I, Division 2, Groups A,B,C,D

VRS332

3

32

265MA-RS

104/40

T-4A

Class I, Division 2, Groups A,B,C,D

VRS240

2

40

430MA-RS

104/40

T-4A

Class I, Division 2, Groups A,B,C,D

VRS340

3

40

430MA-RS

104/40

T-4A

Class I, Division 2, Groups A,B,C,D

VRS260

2

60

800MA-HO

77/25

T-3C

Class I, Division 2, Groups A,B,C,D

DRS232

2

32

265MA-RS

77/25

T-6

Class II, Division 1 & 2 Groups F,G

DRS332

3

32

265MA-RS

77/25

T-6

Class II, Division 1 & 2 Groups F,G

DRS240

2

40

430MA-RS

77/25

T-4

Class II, Division 1 & 2 Groups F,G

DRS340

3

40

430MA-RS

77/25

T-6

Class II, Division 1 & 2 Groups F,G

DRS260

2

60

800MA-HO

77/25

T-6

Class II, Division 1 & 2 Groups F,G

Vaportight Adjustable Hanger or Aligner – Iron Outlet Plugs
•	 Suitable for use in locations where equipment is exposed to the
deteriorating effects of non-combustible atmospheres containing
corrosive fumes, vapors, dust, smoke and/or moisture.
•	 Range of adjustment is 45°. Two-piece ball type cast iron body; gasket
sealed at the adjustable ball joint. Maximum overall length is 53-5/8
inches. Finish is baked white paint over electroplating.
•	 These iron plugs are for closing tapped outlets in explosion-proof
boxes. Plugs are electroplated and finished in baked aluminum paint.
A socket head is provided for square wrenches.

V CSA Certification Only.

1114

Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

VRS™ and DRS™ Fluorescent Luminaires

Enclosed and Gasketed. Suitable for Use in Wet Locations
32 W, 40 W and 60 W Two- and Three-Lamp Fixtures.
VRS:
Class I, Division 2, Groups A, B, C, D

Number of Lamps ➋

Lamp Watts

DRS:
Class II, Division 1 and 2, Groups F, G
Class III

Lamp Type

Unput Volts

Freq. (Hz)

Ballast Type

Catalog Number

VRS 32 W, 40 W and 60 W Fixtures Furnished with 1/4” Clear Tempered Glass Lens ➊
2

32

T8

120-277

50/60

Electronic

VRS232BU

2

40

T12

120-277

50/60

Electronic

VRS240BU

2

60

T12

120-277

50/60

Electronic

VRS260BU

3

32

T8

120-277

50/60

Electronic

VRS332BU

3

40

T12

120-277

50/60

Electronic

VRS340BU

DRS 32 W, 40 W and 60 W Fixtures Furnished with 1/4” Clear Tempered Glass Lens
2

32

T8

120-277

50/60

Electronic

DRS232BU

2

40

T12

120-277

50/60

Electronic

DRS240BU

2

60

T12

120-277

50/60

Electronic

DRS260BU

3

32

T8

120-277

50/60

Electronic

DRS332BU

3

40

T12

120-277

50/60

Electronic

DRS340BU

Lighting

Lighting: Enclosed and Gasketed — Area — Fluorescent
OPTIONS: Add suffix -F for individually fused ballast. Add suffix -EL for emergency battery pack. (For 50Hz with -EL suffix, consult factory for certifications.)
➊ Consult factory for clear high-impact acrylic lens. UL Listed for Class I, Division 2, Groups. A, B, C, D; suitable for use in locations exposed to moisture or noncombustible gases.
➋ Lamps not furnished with fixture.
➌ Low temperature ballast (-20 °F/-29 °C starting) provided as standard.
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

1115

VRS™ and DRS™ Fluorescent Luminaires

Enclosed and Gasketed. Suitable for Use in Wet Locations
32 W, 40 W and 60 W Two- and Three-Lamp Fixtures.

Description

Catalog Number

45° Adjustable Brackets

Two “L-type” brackets with gaskets – adjustable to 45°
in 5° increments for “custom” illumination spread.

DRKHN

Two “L-type” brackets with gaskets for wall or ceiling
mounting – provides wide-spread illumination.

DRAGN

Two heavy-duty bars with holes for chain suspension of
fixtures.

DRCXN

Lens and door frame

VRSLENS

Lens and door frame

DRSLENS

32- and 40 Watt Fixed-end lampholder (Med. Bi-pin)

VRSDRS40SS0C

32- and 40 Watt Plunger-end lampholder (Med. Bi-pin)

VRSDRS40CS0C

60 Watt Fixed-end lampholder (High Output)

VRSDRS60SS0C

60 Watt Plunger-end lampholder (High Output)

VRSDRS60CS0C

45° Fixed Mounting Brackets

Lighting

Angle Bars

Lighting: Enclosed and Gasketed — Area — Fluorescent

Lens and Door Frame

Sockets – Lampholders

Plunger Type

Fixed Type

* Each lamp has a Fixed and Plunger Lampholder

Hubs

Side and Top suspension hubs

1116

VRSDRSHUB

Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

VRS™ and DRS™ Fluorescent Luminaire Photometric Data
Enclosed and Gasketed. Suitable for Use in Wet Locations
32 W, 40 W and 60 W Two- and Three-Lamp Fixtures.

Zone

Lumens

Total Luminaire Efficiency = 73.5%

0-10

145.72

CIE Type – Direct

10-20

421.76

20-30

651.35

30-40

798.47

0-180

1.28

Coefficients of Utilization - Zonal Cavity Method

40-50

824.90

90-270

1.34

Effective Floor Cavity Reflectance 0.20

50-60

701.76

Diagonal

1.44

60-70

498.35

70-80

189.17

80-90

30.32

90-100

0.00

REPORT NUMBER: VRS232
Lamps: Two 32 W Fluorescent Vaportightproof

Spacing
Criteria

Plane

% Ceiling Rcc
% Walls

Zone

70

50

30

10

0

70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0

0 87 87 87 87 85 85 85 85 82 82 82 78 78 78 75 75 75 73

Zonal Lumen Summary

0-30

Rw

80

Lumens % Lamp % Fixture

1 81 77 74 72 79 76 73 71 73 70 68 70 68 66 67 66 64 63

1218.83 21.0

2 74 68 63 59 72 66 62 58 64 60 57 62 58 56 59 57 55 53

28.6

100-110

0.00

0-40

2017.30 34.8

47.3

3 67 60 54 49 65 59 53 49 56 52 48 54 51 47 53 49 46 45

110-120

0.00

0-60

3543.96 61.1

83.2

4 62 53 47 42 60 52 46 42 50 45 41 49 44 41 47 43 40 38

4261.81 73.5

100.0

5 57 47 41 36 55 47 41 36 45 40 36 44 39 35 42 38 35 33

0.0

6 52 43 36 32 51 42 36 31 41 35 31 39 35 31 38 34 31 29

120-130

0.00

0-90

130-140

0.00

90-120

0.00

0.0

0.00

90-130

0.00

0.0

0.0

7 48 39 32 28 47 38 32 28 37 32 28 36 31 27 35 31 27 26

0.00

90-150

0.00

0.0

0.0

8 45 35 29 25 44 35 29 25 34 28 25 33 28 25 32 28 24 23

0.00

0.0

0.0

9 42 32 26 22 41 32 26 22 31 26 22 30 26 22 30 25 22 21

4261.81 73.5

100.0

10 39 30 24 20 39 29 24 20 29 24 20 28 23 20 27 23 20 19

160-170

0.00

90-180

170-180

0.00

180-0

Zone

Lumens

Total Luminaire Efficiency = 70.1%

0-10

126.78

CIE Type – Direct

10-20

367.88

20-30

567.43

30-40

693.10

0-180

1.28

40-50

715.79

90-270

1.32

50-60

620.48

Diagonal

1.42

433.89
163.48

80-90

25.87

90-100

0.00

REPORT NUMBER: VRS240
Lamps: Two 40 W Fluorescent Vaportightproof

Spacing
Criteria

Coefficients of Utilization - Zonal Cavity Method
Effective Floor Cavity Reflectance 0.20
% Ceiling Rcc
% Walls

Zone

70

50

30

10

0

70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0

0 83 83 83 83 81 81 81 81 78 78 78 75 75 75 72 72 72 70

Zonal Lumen Summary

0-30

Rw

80

Lumens % Lamp % Fixture

1 77 74 71 69 75 72 70 67 69 67 65 67 65 63 64 63 61 60

1062.10

2 70 65 60 56 68 63 59 56 61 57 54 59 56 53 57 54 52 51

20.0

28.6

100-110

0.00

0-40

1755.20

33.1

47.3

3 64 57 52 47 62 56 51 47 54 49 46 52 48 45 50 47 44 43

110-120

0.00

0-60

3091.47

58.3

83.2

4 59 51 45 40 57 50 44 40 48 43 39 46 42 39 45 41 38 37

3714.71

70.1

100.0

5 54 45 39 35 53 44 39 34 43 38 34 42 37 34 40 36 33 32

0.00

0.0

0.0

6 50 41 35 30 49 40 34 30 39 34 30 38 33 29 37 32 29 28

120-130

0.00

0-90

130-140

0.00

90-120

140-150

0.00

90-130

0.00

0.0

0.0

7 46 37 31 27 45 36 31 27 35 30 26 34 30 26 33 29 26 25

150-160

0.00

90-150

0.00

0.0

0.0

8 43 34 28 24 42 33 28 24 32 27 23 31 27 23 31 26 23 22

160-170

0.00

90-180

170-180

0.00

180-0

0.00

0.0

0.0

9 40 31 25 21 39 30 25 21 30 25 21 29 24 21 28 24 21 20

3714.71

70.1

100.0

10 38 28 23 19 37 28 23 19 27 23 19 27 22 19 26 22 19 18

Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

1117

Lighting: Enclosed and Gasketed — Area — Fluorescent

60-70
70-80

Plane

Lighting

140-150
150-160

DRS™ Fluorescent Luminaire Photometric Data

Enclosed and Gasketed. Suitable for Use in Wet Locations
32 W, 40 W and 60 W Two- and Three-Lamp Fixtures.

Lighting

Zone

Lumens

Total Luminaire Efficiency = 73.5%

0-10

145.72

CIE Type – Direct

10-20

421.76

20-30

651.35

30-40

798.47

0-180

1.28

40-50

824.90

90-270

1.34

50-60

701.76

Diagonal

1.44

60-70

498.35

70-80

189.17

80-90

30.32

90-100

0.00

Spacing
Criteria

Plane

Coefficients of Utilization - Zonal Cavity Method
Effective Floor Cavity Reflectance 0.20
% Ceiling Rcc
% Walls

Zone

70

50

30

10

0

70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0

0 87 87 87 87 85 85 85 85 82 82 82 78 78 78 75 75 75 73

Zonal Lumen Summary

0-30

Rw

80

Lumens % Lamp % Fixture

1 81 77 74 72 79 76 73 71 73 70 68 70 68 66 67 66 64 63

1218.83

2 74 68 63 59 72 66 62 58 64 60 57 62 58 56 59 57 55 53

21.0

28.6

100-110

0.00

0-40

2017.30

34.8

47.3

3 67 60 54 49 65 59 53 49 56 52 48 54 51 47 53 49 46 45

110-120

0.00

0-60

3543.96

61.1

83.2

4 62 53 47 42 60 52 46 42 50 45 41 49 44 41 47 43 40 38

4261.81

73.5

100.0

5 57 47 41 36 55 47 41 36 45 40 36 44 39 35 42 38 35 33

0.00

0.0

0.0

6 52 43 36 32 51 42 36 31 41 35 31 39 35 31 38 34 31 29

120-130

0.00

0-90

130-140

0.00

90-120

140-150

0.00

90-130

0.00

0.0

0.0

7 48 39 32 28 47 38 32 28 37 32 28 36 31 27 35 31 27 26

150-160

0.00

90-150

0.00

0.0

0.0

8 45 35 29 25 44 35 29 25 34 28 25 33 28 25 32 28 24 23

160-170

0.00

90-180

170-180

0.00

180-0

Zone

Lighting: Enclosed and Gasketed — Area — Fluorescent

REPORT NUMBER: DRS232
Lamps: Two 32 W Fluorescent Dust-Ignitionproof

0.00

0.0

0.0

9 42 32 26 22 41 32 26 22 31 26 22 30 26 22 30 25 22 21

4261.81

73.5

100.0

10 39 30 24 20 39 29 24 20 29 24 20 28 23 20 27 23 20 19

Lumens

Total Luminaire Efficiency = 70.1%

0-10

126.78

CIE Type – Direct

10-20

367.88

20-30

567.43

30-40

693.10

0-180

1.28

Coefficients of Utilization - Zonal Cavity Method

40-50

715.79

90-270

1.32

Effective Floor Cavity Reflectance 0.20

50-60

620.48

Diagonal

1.42

60-70

433.89

70-80

163.48

80-90

25.87

90-100

0.00

Plane

REPORT NUMBER: DRS240
Lamps: Two 40 W Fluorescent Dust-Ignitionproof

Spacing
Criteria

% Ceiling Rcc
% Walls Rw

Zone

70

50

30

10

0

0 83 83 83 83 81 81 81 81 78 78 78 75 75 75 72 72 72 70

Zonal Lumen Summary

0-30

80

70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0

Lumens % Lamp % Fixture

1 77 74 71 69 75 72 70 67 69 67 65 67 65 63 64 63 61 60

1062.10

2 70 65 60 56 68 63 59 56 61 57 54 59 56 53 57 54 52 51

20.0

28.6

100-110

0.00

0-40

1755.20

33.1

47.3

3 64 57 52 47 62 56 51 47 54 49 46 52 48 45 50 47 44 43

110-120

0.00

0-60

3091.47

58.3

83.2

4 59 51 45 40 57 50 44 40 48 43 39 46 42 39 45 41 38 37

3714.71

70.1

100.0

5 54 45 39 35 53 44 39 34 43 38 34 42 37 34 40 36 33 32

0.00

0.0

0.0

6 50 41 35 30 49 40 34 30 39 34 30 38 33 29 37 32 29 28

120-130

0.00

0-90

130-140

0.00

90-120

140-150

0.00

90-130

0.00

0.0

0.0

7 46 37 31 27 45 36 31 27 35 30 26 34 30 26 33 29 26 25

150-160

0.00

90-150

0.00

0.0

0.0

8 43 34 28 24 42 33 28 24 32 27 23 31 27 23 31 26 23 22

160-170

0.00

90-180

170-180

0.00

180-0

1118

0.00

0.0

0.0

9 40 31 25 21 39 30 25 21 30 25 21 29 24 21 28 24 21 20

3714.71

70.1

100.0

10 38 28 23 19 37 28 23 19 27 23 19 27 22 19 26 22 19 18

Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

RE Series Recessed Fluorescent Luminaires

Standard and Emergency Back-Up. Increased Safety
Zone 1 & 2 – 21 & 22
II 2 GD
ATEX / IECEx
IP66 - IK09/10

Applications

4 x 18 W Surface Mounting

Features

Standard Materials
•	 Housing and integral frame: one-piece, welded steel
•	 Safety lens: 0.20"/5 mm thick tempered
•	 Gasket: Silicone, 4 lips, completely sealed and contained 	
in the fixture
•	 Internal reflector: white polycarbonate multi-parabolic
•	 Cable gland and blanking plug: polyamide

Standard Finishes

2 x 36 W Recessed

Certifications and Compliances
•	 Gas: Zones 1 and 2
	 — Conforming to ATEX 94/9/CE: CE 0081   II2 G
	 — ATEX/IEC Protection: Ex de IIC/ Ex demb IIC (emergency
version)
	 — T Rating: T6 to T4 (see T Ratings on following page)
•	 Dust: Zone 22
	 — Conforming to ATEX 94/9/CE: CE 0081
II2 D
	 — ATEX/IEC Protection: Ex tD A21
	 — Surface Temperature: T167 °F /75 °C
•	 Ambient Temperature: -4 °F/-20 °C Ta 131 °F/55 °C
•	 CE Declaration of Conformity: 50276
•	 ATEX Certificate: LCIE 07 ATEX 6104
•	 IECEx Certificate: IECEx LCI 07.0019
•	 Index of Protection: IP66
•	 Impact of Resistance: IK09 or IK10 depending on version
•	 Ex standards :EN / IEC 60079-0; 60079-1; 60079-7; 60079-18
61241-0; 61241-1
•	 Product standards: EN / IEC 60598-1; 60598-2-22
•	 EMC standards: EN / IEC 55015; 61547
•	 Other standards: EN / IEC 60529 (IP); 62262 (IK)

•	 Housing and integral frame: white powder epoxy paint

Options
•	 316L stainless steel housing and integral frame, natural finish.
•	 Through wiring.
•	 White powder epoxy painted steel reflector.

Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

1119

Lighting

•	 One-piece welded steel housing with integral frame to 	
seal out contaminants.
•	 Allows recessed mounting in permanent ceilings from 	
55 mm to 130 mm (2" to 5" approximately).
•	 Frameless tempered (safety) 5 mm (1/4") thick lens. 	
Lens secured to housing by internal metallic hinges	
and secured with captive 316L stainless steel screws, 	
allowing for easy lamp replacement and fixture maintenance.
•	 Positive safety switch and new Ex e battery with
plug-in connector for safety and easy maintenance 	
in hazardous locations.
•	 Designed for ease of installation and maintenance.
•	 Bi-pin G13 lampholder.
•	 Also available as surface mounting version.
•	 New ballast:
— EOL (End Of Life) protection in accordance to the latest EN
60079-7 standard
— Multi-tap 110 to 254 Vac/Vdc +/-10% 50/60 Hz
— Two channel standard ballast (if one lamp fails the second
lamp remains in operation)
— Ex e plug-in connector for rapid and error free maintenance
— Self test on 3 hours duration emergency version
— High power factor electronic ballast (>0.95)
•	 Cable entries:
— Three clearance holes for M20 cable gland supplied with M20
polyamide cable gland (cable dia. 0.26 to 0.57" / 6.5 to 14.5
mm) and M20 polyamide blanking plug as below quantity:
— One M6 earth stud.

Lighting: Enclosed and Gasketed — Area — Recessed Fluorescent

•	 Designed for flush or surface mounting; most specifically 	
clean room environments where a seamless smooth ceiling 	
is mandatory.
•	 Typical applications include: the food industry, chemical 	
plants, pharmaceuticals and delicate electronic manufacturing
such as the aerospace industry.
•	 Ideal for rigorous corrosive environments, involving water, 	
dust and extreme temperature variations.
•	 Can be installed in hazardous areas designated as Zone 	
1, 2, 21 and 22.

RE Series Recessed Fluorescent Luminaires

Standard and Emergency Back-Up. Increased Safety
Zone 1 & 2 – 21 & 22
II 2 GD
ATEX / IECEx
IP66 - IK09/10

Order using catalog numbering guide below or select catalog number from tables on following pages.
Catalog Numbering Guide For FL Non-Metallic Fluorescent Lighting Fixtures
RE

B

1

18

Lighting

Lighting: Enclosed and Gasketed — Area — Recessed Fluorescent

Series:
RE - RE Series

BU

L

Options:
E - 3H Emergency (combined) - Battery
6 V - 4 Ah
E1 - 1 H 30 Emergency (combined)
- Battery 6 V - 7 Ah
E7 - 3H Emergency (combined) Battery 6 V - 7 Ah
N - No switch ③
P - White painted steel internal
reflector ①
S - 316L Stainless steel housing)

Wattage:
18 - 18 Watt
36 - 36 Watt
58 - 58 Watt

Lamp Type:
B - Bi-pin (G13)

E

Voltage:
B3 - 100 to 130 Vac/Vdc
50/60 Hz
BU - 110 to 254 Vac/Vdc
50/60 Hz
BK - 220 to 240 Vac/Vdc
50/60 Hz
Number of Lamps:
1 - Single
2 - Double
3 - Three Lamps
4 - Four Lamps

Termination/Wiring:
L - Loop In/Loop Out
T - Through wired ②

	

T Ratings

Version

Termination and Wiring
Ambient Temperature
Ceiling Position
Wall Position
104 °F/ 122 °F/ 131 °F/ 104 °F/ 122 °F/ 131 °F/
40 °C
50 °C
55 °C
40 °C
50 °C
55 °C

2 x 18 W ④

T6

T5

T5

T5

T5

T4

2 x 18 W Emergency ④

T5

T4

T4

T5

T5

T4

3 x 18 W

T5

T4

T4

T4

T4

T4

4 x 18 W

T5

T4

T4

T5

T4

T4

2 x 36 W ④

T5

T4

T4

T5

T4

T4

2 x 36 W Emergency ④

T5

T4

T4

T5

T4

T4

3 x 36 W

T4

T4

T4

T4

T4

T4

4 x 36 W

T5

T4

T4

T5

T4

T4

2 x 58 W ④

T4

T4

T4

T4

T4

T4

2 x 58 W Emergency ④

T4

T4

T4

T4

T4

T4

3 x 58 W

T4

T4

T4

T4

T4

4 x 58 W

T4

T4

T4

T4

T4

•	 Terminal capacity: 0.006 in2/4 mm2 (flexible) or
0.009in2/6 mm2 (solid).
•	 Loop in/Loop out: One terminal block ⑤
— Standard version: 	
2 (L) + 2 (N) + 2 (PE)
— Emergency version: 	
2 (LP) + 2 (L) + 2 (N) + 2 (PE)
•	 Through wired: Two terminal blocks (one at each
end) ⑤
— Standard version: 	
2 (L) + 2 (N) + 2 (PE)	
1 (L) + 1 (N) + 1 (PE)
— Emergency version: 	
2 (LP) + 2 (L) + 2 (N) + 2 (PE)	
	1 (LP) + 1 (L) + 1 (N) + 1 (PE)

T4

Version
Loop

Cable Gland
1

Blanking
Plug
1

Nickel
Plated
Brass
Locknut
3

T4

Through

2

1

3

① As standard for 18 W emergency version and 4 lamp version.
② T/W and Loop in/Loop out - 3 cores (single phase).
③ Only for standard versions.
④ T rating for single lamp version is the same as twin lamp version.
⑤ PE: Earth; N: Neutral. L: Live. LP: Permanent Live for emergency version.

1120

Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

RE Series Recessed Fluorescent Luminaires

Standard and Emergency Back-Up. Increased Safety
Zone 1 & 2 – 21 & 22
II 2 GD
ATEX / IECEx
IP66 - IK09/10

Recessed — 110/254 Vac/Vdc 50/60 Hz — Front access — White Painted Steel Housing
Version

Wiring

Reflector

Weight (lbs/kg)

Volume (in3/dm3)

Catalog Number

Standard Version — Bi-pin Lamps (G13)
Loop

Polycarbonate

30.86/14

3905.52/64

REB218BUFL

2 x 18 W

Through

Polycarbonate

30.86/14

3905.52/64

REB218BUFT

4 x 18 W

Loop

White Painted Steel

46.30/21

5675.21/93

REB418BUFLP

4 x 18 W

Through

White Painted Steel

46.30/21

5675.21/93

REB418BUFTP

2 x 36 W

Loop

Polycarbonate

41.89/19

6590.56/108

REB236BUFL

2 x 36 W

Through

Polycarbonate

41.89/19

6590.56/108

REB236BUFT

4 x 36 W

Loop

White Painted Steel

63.93/29

9641.75/158

REB436BUFLP

4 x 36 W

Through

White Painted Steel

63.93/29

9641.75/158

REB436BUFTP

2 x 58 W

Loop

Polycarbonate

48.50/22

7933.09/130

REB258BUFL

2 x 58 W

Through

Polycarbonate

48.50/22

7933.09/130

REB258BUFT

4 x 58 W

Loop

White Painted Steel

70.55/32

11594.51/190

REB458BUFLP

4 x 58 W

Through

White Painted Steel

70.55/32

11594.51/190

REB458BUFTP

3 Hours Emergency Version — Bi-pin Lamps (G13)
2 x 18 W

Loop

Polycarbonate

30.86/14

3905.52/64

REB218BUFLEP

2 x 18 W

Through

Polycarbonate

30.86/14

3905.52/64

REB218BUFTEP

4 x 18 W

Loop

White Painted Steel

46.30/21

5675.21/93

REB418BUFLEP

4 x 18 W

Through

White Painted Steel

46.30/21

5675.21/93

REB418BUFTEP

2 x 36 W

Loop

Polycarbonate

41.89/19

6590.56/108

REB236BUFLE

2 x 36 W

Through

Polycarbonate

41.89/19

6590.56/108

REB236BUFTE

4 x 36 W

Loop

White Painted Steel

63.93/29

9641.75/158

REB436BUFLEP

4 x 36 W

Through

White Painted Steel

63.93/29

9641.75/158

REB436BUFTEP

2 x 58 W

Loop

Polycarbonate

48.50/22

7933.09/130

REB258BUFLE

2 x 58 W

Through

Polycarbonate

48.50/22

7933.09/130

REB258BUFTE

4 x 58 W

Loop

White Painted Steel

70.55/32

11594.51/190

REB458BUFLEP

4 x 58 W

Through

White Painted Steel

70.55/32

11594.51/190

REB458BUFTEP
Lighting

For non-recessed lighting, please replace letter “F” with letter “M” as per Catalog number logic. Example: REB218BUFL becomes REB218BUML.

Accessories
Description

Weight (lbs/kg)

Catalog Number

Fixing Brackets - Set of four.
Zinc plated steel

1.32/0.60

REFBST

316 stainless steel

1.32/0.60

REFBSS

Ceiling Mounting Brackets - Set of two
Zinc plated steel

4.41/2.00

RECMST

316 stainless steel

4.41/2.00

RECMSS

Zinc plated steel

0.55/0.25

REEBST

316 stainless steel

0.55/0.25

REEBSS

M8 Eye Bolts - Set of four

Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

Lighting: Enclosed and Gasketed — Area — Recessed Fluorescent

2 x 18 W

1121

RE Series Recessed Fluorescent Luminaires

Standard and Emergency Back-Up. Increased Safety
Zone 1 & 2 – 21 & 22
II 2 GD
ATEX / IECEx
IP66 - IK09/10

Wiring Diagram

Emergency Function Diagram
Two Lamp Version

Mains
PE	

N	

L

Mains

Lighting: Enclosed and Gasketed — Area — Recessed Fluorescent

Lighting
Switch

Lighting Switch ON

Lighting Switch OFF

Lighting Switch ON

Lighting Switch OFF

ON

L’

U
N
PE

OFF
Standard Fluorescent
Lighting Fixture

Three Lamp Version
Mains
ON

U’
U
N
PE

Emergency Fluorescent
Lighting Fixture

OFF

LED Status
Color

Lighting

Green

Indication
LED glows

Function
Batteries are connected

LED blinks

Batteries are charged

Red

LED blinks

Batteries are not connected or defect

Yellow

LED blinks

Batteries are charging and discharging during automatic cycle

Emergency Light Duration
Version

Battery Capacity

Duration

Light Output

2 x 18 W

4 Ah – 6 V

3 hours

45%

4 Ah – 6 V

3 hours

15%

7 Ah – 6 V

3 hours

25%

4 Ah – 6 V

3 hours

9%

7 Ah – 6 V

3 hours

15%

2 x 36 W
2 x 58 W

1122

Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

RE Series Recessed Fluorescent Luminaire Dimensions

Standard and Emergency Back-Up. Increased Safety
Zone 1 & 2 – 21 & 22
II 2 GD
ATEX / IECEx
IP66 - IK09/10

Dimensions in Inches/Millimeters
Recessed

Surface Mounting
A

A

C

D

0.08”/
2.0 mm

5.30”/
134.5 mm

5.23”/
132.5 mm

Lighting: Enclosed and Gasketed — Area — Recessed Fluorescent

B

B

C

D

E

E

4 x Ø 0.33”/8.5 mm

  F

4 x Ø 0.33”/8.5 mm

  F

Ceiling Cut-out
G

H

A

B

C

D

E

F

G

H

32.52/826

12.60/320

10.63/270

30.55/776

15.35/390

7.24/184

30.94/786

11.02/280

18 W (4 lamps)

32.52/826

19.29/490

17.32/440

30.55/776

15.35/390

13.94/354

30.94/786

17.72/450

36 W (1, 2, 3 lamps)

56.54/1436

12.60/320

10.63/270

54.57/1386

39.37/1000

7.24/184

54.96/1396

11.02/280

36 W (4 lamps)

56.54/1436

19.29/490

17.32/440

54.57/1386

39.37/1000

13.94/354

54.96/1396

17.72/450

58 W (1, 2, 3 lamps)

68.35/1736

12.60/320

10.63/270

66.38/1686

51.18/1300

7.24/184

66.77/1696

11.02/280

58 W (4 lamps)

68.35/1736

19.29/490

17.32/440

66.38/1686

51.18/1300

13.94/354

66.77/1696

17.72/450

Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

1123

Lighting

Versions
18 W (1, 2, 3 lamps)

RE Series Recessed Fluorescent Luminaire Photometric Data

Standard and Emergency Back-Up. Increased Safety
Zone 1 & 2 – 21 & 22
II 2 GD
ATEX / IECEx
IP66 - IK09/10

Longitudinal
Transverse

Polar curves for a 1000 lm flux, according to NF C 71-120
Luminaire symbol according to NF C 71-121

Lighting

Lighting: Enclosed and Gasketed — Area — Recessed Fluorescent

1 x 18 W
Efficiency 67.1%
NF C 71-121: 0.67 E

2 x 18 W
Efficiency 62%
NF C 71-121: 0.62 E

3 x 18 W
Efficiency 61.2%
NF C 71-121: 0.61 E

Candela Distribution

Candela Distribution

0-180 90-270

0-180 90-270

Candela Distribution
0-180 90-270

0

209

209

0

205

205

0

201

5

Degrees
208
208

5

Degrees 203
204

5

Degrees 201
200

201

10

205

208

90°

10

202

203

90°

10

197

201

90°

15

201

207

75°

15

197

202

75°

15

193

200

75°

20

194

205

20

191

201

60°

20

187

197

60°

25

186

203

25

182

201

25

179

195

30

176

201

30

173

200

30

169

192

35

164

197

35

161

192

35

158

189

40

151

192

40

148

183

40

145

181

45

136

185

45

133

177

45

131

170

50

120

177

50

117

173

50

115

155

55

102

164

55

99

168

55

98

132

60

83

141

60

80

168

60

80

107

65

63

115

65

61

163

65

61

80

70

43

77

70

41

154

70

41

53

60°
45°

30°

0°	

15°

2 x 18 W
Efficiency 60.5%
NF C 71-121: 0.60 F

0
5
10
15
20
25
30
35
40
45
50
55
60
65
70

30°

0°	

15°

45°

30°

0°	

15°

4 x 18 W
Efficiency 63.7%
NF C 71-121: 0.63 E

Candela Distribution
0-180 90-270
196Degrees 196
195
196
193
195
189
195
183
193
175
191
166
187
155
182
143
174
129
162
114
147
98
131
79
109
60
85
40
62

45°

Candela Distribution

90°
75°
60°
45°

30°
0°	

15°

0
5
10
15
20
25
30
35
40
45
50
55
60
65
70

0-180 90-270
194
Degrees 194
193
194
191
195
186
195
181
193
173
192
164
190
153
185
141
179
128
171
113
160
96
146
78
127
60
106
40
82

90°
75°
60°
45°

30°
0°	

15°

4 x 36 W
Efficiency 61.5%
NF C 71-121: 0.61 E

Candela Distribution
0
5
10
15
20
25
30
35
40
45
50
55
60
65
70

1124

0-180 90-270
190
190
Degrees
289
190
287
190
183
189
177
188
170
186
162
182
151
178
139
172
126
163
111
152
96
138
78
121
60
102
42
80

90°
75°
60°
45°

30°

0°	

15°

Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

RE Series Recessed Fluorescent Luminaire Photometric Data

Standard and Emergency Back-Up. Increased Safety
Zone 1 & 2 – 21 & 22
II 2 GD
ATEX / IECEx
IP66 - IK09/10

Longitudinal
Transverse

Polar curves for a 1000 lm flux, according to NF C 71-120
Luminaire symbol according to NF C 71-121
1 x 36 W
Efficiency 64.4%
NF C 71-121: 0.64 E

2 x 36 W
Efficiency 64.8%
NF C 71-121: 0.64 E

3 x 36 W
Efficiency 63.7%
NF C 71-121: 0.63 F

Candela Distribution

0-180 90-270

0-180 90-270

Candela Distribution
0-180 90-270

0

196

196

0

198

198

0

207

5

195Degrees 196

5

197Degrees 198

5

207Degrees 208

207

10

192

196

90°

10

194

198

90°

10

204

208

90°

15

188

194

15

190

197

75°

15

199

206

75°

20

182

192

75°

20

184

196

20

193

204

25

174

189

25

176

195

25

185

202

30

165

188

30

167

195

30

175

200

35

154

185

35

156

194

35

164

196

40

152

181

40

144

191

40

151

189

45

129

176

45

130

184

45

136

178

50

114

170

50

115

172

50

120

162

55

97

159

55

98

154

55

103

139

60

80

143

60

80

129

60

84

112

65

61

116

65

62

101

65

65

83

70

43

76

70

43

72

70

45

55

60°
45°

30°

0°	

15°

1 x 58 W
Efficiency 64.9%
NF C 71-121: 0.65 E

45°

30°

0°	

15°

2 x 58 W
Efficiency 61.8%
NF C 71-121: 0.62 E

Candela Distribution

0-180 90-270
189 Degrees189
188
189
187
188
184
187
181
186
176
185
170
185
162
184
150
180
136
175
119
169
102
162
83
146
63
122
43
85

0-180 90-270
182 Degrees182
182
183
181
183
178
182
174
182
170
182
164
181
156
181
145
178
131
172
116
162
99
148
81
126
52
99
43
70

90°
75°
60°
45°

30°

0°	

15°

0
5
10
15
20
25
30
35
40
45
50
55
60
65
70

Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

60°
45°

30°

0°	

15°

3 x 58 W
Efficiency 57.8%
NF C 71-121: 0.58 E

Candela Distribution

90°
75°
60°
45°

30°

0°	

15°

0
5
10
15
20
25
30
35
40
45
50
55
60
65
70

0-180 90-270
185 Degrees185
185
185
183
185
181
184
177
182
172
180
166
178
159
174
147
168
133
158
118
144
100
125
82
101
63
75
43
49

90°
75°
60°
45°

30°

0°	

15°

1125

Lighting

Candela Distribution
0
5
10
15
20
25
30
35
40
45
50
55
60
65
70

60°

Lighting: Enclosed and Gasketed — Area — Recessed Fluorescent

Candela Distribution

Stylmaster™ Incandescent Luminaires
Enclosed and Gasketed

Attractively styled fixture with prismatic globe. UNILETS® for use with threaded metal conduit.
NEC:
Class I, Division 2, Groups A, B, C, D

CSA: V
Class I, Division 2, Groups A, B, C, D
Class II, Division 1 and 2, Groups E, F, G
Class III
Enclosure 4X

Applications
•	 Enclosed and gasketed lighting fixtures for use in storage
areas, tunnels, subways, chemical plants and other areas where
moisture, dirt or corrosive atmospheres are a problem.
•	 Suitable for use in wet locations.
•	 Standard fixtures designed for 60 to 300 Watt medium base
incandescent lamps.
•	 Pendant, feed-thru, ceiling, stanchion and wall mounts available.
•	 Ventilated steel reflectors with white porcelain finish are
available for standard applications. Fiberglass reinforced
polyester reflectors are designed for installations where fixture
is subject to severe corrosive conditions or vandalism.

Lighting: Enclosed and Gasketed — Area — Incandescent

Features
•	 Modern styling, with clean-line mounting hood and prismatic
glass globe, plus optional guard.
•	 Prismatic globe, furnished as standard, eliminates glare 	
and distributes light evenly.
•	 Globe seats firmly against composition gasket in mounting
hood to keep out dirt and moisture. Full threads eliminate
“cross threading.”
•	 Fixture is complete with gaskets and socket. Socket is shockabsorbing to prolong lamp life and can be easily removed for
wiring without tools.
•	 Porcelain socket construction assures long trouble-free
operation in high ambient installations.
•	 Both porcelain steel and polyester reflectors are secured to
mounting hoods with screws (furnished).
•	 Guards have exclusive snap-on attachment feature for quick
installation and fast servicing.
•	 Choice of reflector styles: 	
(1) steel reflector with white porcelain enamel in standard dome
and 30º angle	
(2) fiberglass reinforced polyester reflector in standard dome
and 30º angle.
•	 Maximum input voltage 277 V (suitable for DC applications).

Illustrated Features
Mounting Hood
Pendant style shown has setscrew to prevent
fixture stem from turning. Other styles include
stanchion, ceiling and wall mounting.
Shock-Absorbing Medium Base Socket
Spring absorbs vibration to prolong lamp
life. Porcelain construction for trouble-free
operation in high ambient installations.
Globe
Attractive, tapered prismatic glass globes 	
for glare elimination and uniform light
distribution. Colors available – also 	
vandal-resistant plastic globes. Globe seats
firmly against gasket to exclude moisture, dirt
and vapors.
Guard
Snap-on guards (and reflectors) – simply
snap-in and twist. Spring action balls snap
into detents of fixture body.

Standard Materials
•	
•	
•	
•	
•	

Mounting hoods: copperfree (4/10 of 1% max.) aluminum
Guards: pressure cast copperfree (4/10 of 1% max.) aluminum
Reflectors: porcelain steel or fiberglass reinforced polyester
Socket: porcelain with brass screw shell
Globes: prismatic glass

Guard and Reflectors

Standard Finishes
•	
•	
•	
•	

Mounting hoods and guards: epoxy powder coat
Steel reflectors: baked white porcelain enamel
Fiberglass reinforced polyester reflectors: natural finish
Socket and globes: natural finish

Lighting

Options
•	 To order fixture with other than standard clear glass globe, add
suffix letters to catalog number as indicated in table, and adjust
difference in price.
Color
Amber
Blue
Green
Red
Clear Heat-Resistant

Glass Globe
-AM
-BL
-GR
-RE
-HR

Plastic Globe
-PAM
-PBL
-PGR
-PRE
—

Certifications and Compliances
•	
•	
•	
•	

UL Standard: UL 1598, UL 844
UL Listed: E10444
CSA Standard: C22.2 No. 250, C22.2 No. 137
CSA Certified: 025428

V CSA Certification only.

1126

Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

Stylmaster™ Incandescent Luminaire Thermal Suitability
Enclosed and Gasketed

Attractively styled fixture with prismatic globe. UNILETS® for use with threaded metal conduit.
NEC:
Class I, Division 2, Groups A, B, C, D

CSA: V
Class I, Division 2, Groups A, B, C, D
Class II, Division 1 and 2, Groups E, F, G
Class III
Enclosure 4X

Class I, Division 2, Groups A, B, C, D
Fixture is suitable for Class I, Division 2 where the fixture operating temperature does not exceed the ignition 	
temperature of the atmosphere in which fixture is installed.
“T” Numbers Represent the Maximum Lamp Temperature for Class I, Division 2 Locations
Supply Wire: 392 ºF/200 ºC

“T”
Number

T1

350

325

T2

T2A

T2B

T2C

T2D

T3

T3A

T3B

T3C

T4

T4A

T5

T6

Temp.
Range
(˚ºF)

664842

619662

574617

538572

502536

448500

421446

394419

358392

331356

322329

277320

250275

214248

187212

185

Temp.
Range
(˚ºC)

351450

326350

301325

281300

261280

231260

216230

201215

181200

166180

161165

136160

121135

101120

86-100

85

Class I, Division 2, Groups A, B, C, D
VPGL-1HR (60-200 W)
A-21
A-23
150 W
200 W

A-23
200 W

PS-25
200 W

VPGL-2HR (200-300 W)
PS-30
PS-25
200 W
300 W

PS-30
300 W

T3

T2D

T2C

T2C

T2C

T2C

325

325

Standard Dome

T2D

T2D

T2B

T2B

T2B

T2C

325

325

30º Angle

T2D

T2C

T2B

T2B

T2B

T2B

325

325

None

Fixture Ambient Suitability:
Class II, Groups E, F, G; Class III; Enclosure 4X

Fixture Ambient Suitability:
Areas

ºF

ºC

Fixture

Watts

Non-Classified

392

200

A-23

60 to 300

Classified

104

40

PS-30

60 to 300

Lighting: Enclosed and Gasketed — Area — Incandescent

Reflector

A-21
100 W

Lighting

V CSA Certification only.
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

1127

Stylmaster™ Incandescent Luminaires
Enclosed and Gasketed

Attractively styled fixture with prismatic globe. UNILETS® for use with threaded metal conduit.
NEC:
Class I, Division 2, Groups A, B, C, D

Without Guard

With Guard

CSA: V
Class I, Division 2, Groups A, B, C, D
Class II, Division 1 and 2, Groups E, F, G
Class III
Enclosure 4X

Type

Lamp
Watts

NEC Catalog Numbers
With Globe
With
and Guard
Globe Only

Hub Size
(Inches)

CSA Catalog Numbers V
With Globe
With
and Guard
Globe Only

Pendant — 3/4” tapped opening — Furnished with 3/4” to 1/2” reducer
A-23

60-200

1/2 or 3/4

VPA1075G

VPA1075

VCA1075G

VCA1075

PS-30

200-300

1/2 or 3/4

VPA2075G

VPA2075

VCA2075G

VCA2075

A-23

60-200

PS-30

200-300

1/2

VPX1050G

VPX1050

3/4

VPX1075G

VPX1075

1/2

VPX2050G

VPX2050

3/4

VPX2075G

VPX2075

—
VCX1075G

—
VCX2075G

—
VCX1075

—
VCX2075

Ceiling – Outlet Box Mounting — Fits SEH ➊ or VPJB cast outlet box, or 4” octagonal outlet box — Furnished with screws and
gasket — Octagonal outlet boxes for non-classified areas only
A-23

60-200

3/4

VPOB10G

VPOB10

VCOB10G

VCOB10

PS-30

200-300

3/4

VPOB20G

VPOB20

VCOB20G

VCOB20

A-23

60-200

1-1/4

VPAN10125G

VPAN10125

VCAN10125G

VCAN10125

PS-30

200-300

1-1/4

VPAN20125G

VPAN20125

VCAN20125G

VCAN20125

45˚ Stanchion – 1-1/4” Conduit

Lighting

Lighting: Enclosed and Gasketed — Area — Incandescent

Ceiling – Five Tapped Openings — With mounting lugs and four close-up plugs

➊ Order SEH box from catalog Fittings Section, 4” octagonal steel boxes from the Commercial Products Section and VPJB cast box from this Section.
V CSA Certification only.

1128

Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

Stylmaster™ Incandescent Luminaires
Enclosed and Gasketed

Attractively styled fixture with prismatic globe. UNILETS® for use with threaded metal conduit.
NEC:
Class I, Division 2, Groups A, B, C, D

CSA: V
Class I, Division 2, Groups A, B, C, D
Class II, Division 1 and 2, Groups E, F, G
Class III
Enclosure 4X

NEC Catalog Numbers
CSA Catalog Numbers V
With Globe
With
With Globe
With
Lamp
Hub Size
and Guard
Globe Only
and Guard
Globe Only
Without Guard
With Guard
Type
Watts
(Inches)
Wall – Body includes outlet box with five tapped openings — With mounting lugs and four close-up plugs
A-23

60-200

PS-30

200-300

1/2

VPWB1050G

VPWB1050

3/4

VPWB1075G

VPWB1075

1/2

VPWB2050G

VPWB2050

3/4

VPWB2075G

VPWB2075

VCWB1075G

VCWB1075

VCWB2075G

VCWB2075

Wall – Outlet Box Mounting — Fits SEH ➊ or VPJB cast outlet box, or 4” octagonal outlet box — Furnished with screws and gasket
— Octagonal outlet boxes for non-classified areas only
60-200

VPOBW10G

VPOBW10

VCOBW10G

VCOBW10

PS-30

200-300

VPOBW20G

VPOBW20

VCOBW20G

VCOBW20

Wall – Outlet Box Mounting with Side Hubs — With two side hubs and one close-up plug
A-23

60-200

3/4

—

—

VCW1075G

VCW1075

PS-30

200-300

3/4

—

—

VCW2075G

VCW2075

Lighting: Enclosed and Gasketed — Area — Incandescent

A-23

Lighting

➊ Order SEH box from catalog Fittings Section, 4” octagonal steel boxes from the Commercial Products Section and VPJB cast box from this Section.
V CSA Certification only.
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

1129

Stylmaster™ Incandescent Luminaire Accessories
Enclosed and Gasketed

Attractively styled fixture with prismatic globe. UNILETS® for use with threaded metal conduit.

Hub Size
(Inches)

Description

Catalog Numbers
NEC

CSA V

Pendant
Furnished with setscrew, 3/4” to 1/2” reducer for 1/2”
stem, medium base socket.

VPA75

VCA75

VPX50

VCX50

Ceiling – Five Tapped Openings
1/2
Four close-up plugs
VCX75

3/4

Lighting: Enclosed and Gasketed — Area — Incandescent

45º Stanchion
1-1/4

VPAN125

VCAN125

1/2

VPWB50

—

3/4

VPWB75

—

1/2

VPJB50

VCJB50

3/4

VPJB75

VCJB75

VPOB1

VCOB1

VPOBW1

VCOBW1

Wall – Five Tapped Openings in Outlet Box ➊
Four close-up plugs

Cast Outlet Box Only – Five Tapped Openings
Four close-up plugs. No socket. Fits VPOB, VPOBW
and VPWB.

Ceiling – For Outlet Box
(Octagonal outlet boxes for non-classified areas only)
Fits SEH or VPJB cast outlet box, or 4” octagonal outlet
box. With screws and gasket.
Wall – For Outlet Box ➊
(Octagonal outlet boxes for non-classified areas only)

Lighting

Fits SEH or VPJB cast outlet box, or 4” octagonal outlet
box. With screws and gasket.
Wall – Outlet Box Mounting with Side Hubs — With two side hubs and one close-up plug
(Octagonal outlet boxes for non-classified areas only)
3/4

—

VCB75

➊ Use 30º angle reflectors for wall installations – center line of fixture must be located at least 5-3/4” away from wall. Has four 3/16” dia. mounting holes located
90º apart on a 3-1/2” dia. center.
V CSA Certification only.

1130

Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

Stylmaster™ Incandescent Luminaire Accessories
Enclosed and Gasketed

Attractively styled fixture with prismatic globe. UNILETS® for use with threaded metal conduit.

Catalog Numbers
Type

Lamp Watts

Color

Glass

Polycarbonate
VPGL-2PL

Glass and Polycarbonate Globes ➊

A-23
Glass Globe
(VPGL-1HR)

Clear

—

Clear Heat-Resistant

VPGL-1HR

—

Amber

VPGL-1AM

VPGL-2AMPL

Blue

VPGL-1BL

VPGL-2BLPL

Green

VPGL-1GR

VPGL-2GRPL

Red

VPGL-1RE

VPGL-2REPL

60-200

Polycarbonate Globe
(VPGL-2PL)

Glass Globes
—

—

VPGL-2HR

—

PS-30

Amber

VPGL-2AM

—

Blue

VPGL-2BL

—

Green

VPGL-2GR

—

VPGL-2RE

—

VPGL-2HRT

—

Red
Glass Globe (VPGL-2HR)
Coated Tuff-Skin ® † Glass Globes Contains globe safely even if glass is broken

Heat-Resistant

VPGL-2HRT
Type

Lamp Watts

A-23
PS-30

60-200
200-300

Catalog Numbers
NEC

CSA V

VPGU-1
VPGU-2

VCFGU-1
VCFGU-2

VPLR-123

VCLR-1

VPGL-GK

VCGL-GK

Guards

VPGU-1

VPGU-2

Lighting: Enclosed and Gasketed — Area — Incandescent

Clear
Clear Heat-Resistant

200-300

Replacement Porcelain Shock-Absorbing Sockets
A-23

60-200

PS-30

200-300

Lighting

Medium Base
Replacement Gasket for Globes
Neoprene – for all Stylmaster globes
Globe Gasket
† Registered trademark of Thomas Manufacturing Corporation, Parkton, Md.
➊ Shatter-resistant for use in food processing plants, canneries, dairies, breweries, bakeries or anywhere broken glass would prove a hazard. Ideally suited for
areas where vandalism, high replacement and high maintenance costs are a problem. CAUTION: Use maximum 200 W lamp less reflector, 100 W max. with
reflector or colored globe. Do not use in ambients exceeding 25 ºC/77 ºF. For burning in vertical base-up position only.
V CSA Certification only.
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

1131

Stylmaster™ Incandescent Luminaire Reflectors and Accessory Weights
Enclosed and Gasketed

Attractively styled fixture with prismatic globe. UNILETS® for use with threaded metal conduit.

Catalog Number
Description

Porcelain Steel

Polyester

Standard Dome Reflector

LPR-25ST

LPRP-25ST

30º Angle Reflector

LPR-25AN

LPRP-25AN

Typical Mounting Hoods
Pendant
VPA75
VCA75

lbs/kg
2/0.9

Ceiling
VPX75
VCX75

lbs/kg
2/0.9

Wall
VPOBW10
VCOBW10

lbs/kg
3/1.4

Stanchion

lbs/kg

VPAN-125

3/1.4

VCAN-125

Globes and Guards

Reflectors

Type

Globe

lbs/kg

Guard

lbs/kg

Standard
Dome

lbs/kg

30˚º Angle

lbs/kg

60-200 W

VPGL-1

2/0.9

VPGU-1

1/0.5

LPR-25ST

3/1.4

LPR-25AN

2/0.9

200-300 W

VPGL-2

3/1.4

VPGU-2

1/0.5

LPRP-25ST

2/0.9

LPRP-25AN

2/0.9

Lighting

Lighting: Enclosed and Gasketed — Area — Incandescent

Weights

1132

Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

Stylmaster™ Incandescent Luminaire Dimensions
Enclosed and Gasketed

Attractively styled fixture with prismatic globe. UNILETS® for use with threaded metal conduit.

Pendant Mount ➊

45° Stanchion Mount ➊➋

7.00"/
177.8 mm

10.55"/268.0 mm
9.23"/
234.4 mm

3.00"/
76.2 mm

Ceiling Outlet Box Mount

Ceiling Mount for Junction Box

4.06"/
103.1 mm

1.68"/
42.7 mm †

Wall Outlet Box Mount
5.25"/
133.4 mm

3.50"/
88.9 mm
4.00"/
101.6 mm

3.31"/
84.1 mm †
3.56"/
90.4 mm †
10.63"/
270.0 mm

0.19”/4.8 mm
Dia. Mtg. Hole

3.31"/
84.1 mm
8.75"/
222.3 mm

Junction Box Mounting Body
0.33"/8.4 mm R	
(+ DFT) (2 PLACES)
0.13"/3.3 mm R. Max
(8 Places)
0.22"/5.6 mm R
(+ DFT) (2 PLACES)

40
.1

1.88"/
47.8 mm

6
1.
10

FT
"/ .C
D
50 B
3. m / 2"
FT
m
0" . .9 .6 ia
"D
88 3 m D 0"/ +2
.
m .0 ia /
4
D
m 5" m
m 4.7 7 m
0.
12

4
.4
91

m 1.5
m 8
Di "/
a.
+

4.00"/
101.6 mm

DF
T

Lighting: Enclosed and Gasketed — Area — Incandescent

4.00"/
101.6 mm

Wall Mount with Junction Box
7.13"/
181.1 mm

7.00"/
177.8 mm

7.00"/
177.8 mm

7.52"/
191.0 mm

8.08"/
205.2 mm

8.52"/
216.4 mm

8.40"/
213.4mm

6.08"/
154.4 mm

5.96"/
151.4 mm

3.00"/
76.2 mm
6.88"/
174.8 mm

6.52"/
165.6 mm

12.08"/306.8 mm
11.19"/
284.2 mm

Lighting

➊ Height of hood is measured to bottom of flange. Height of globe and guard is from bottom of flange.
➋ Dimensions of angle are from center of pipe. Height is measured from pipe stop in stanchion hood.

Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

1133

Stylmaster™ Incandescent Luminaire Dimensions
Enclosed and Gasketed

Attractively styled fixture with prismatic globe. UNILETS® for use with threaded metal conduit.

Without Reflector

Effective Floor Cavity Reflectance (Rfc) is 20%
% Ceiling Rcc
% Walls

Rw

80
50

30

70
10

50

30

50
10

50

30

30
10

50

30

10
10

50

30

0
10

0

1 .739 .689 .645 .684 .640 .598 .583 .548 .517 .489 .464 .439 .404 .384 .365 .322

ROOM CAVITY RATIOS

2 .618 .548 .489 .572 .509 .456 .484 .435 .391 .403 .365 .331 .329 .299 .273 .234
3 .527 .449 .386 .487 .416 .360 .411 .355 .308 .340 .297 .259 .275 .240 .210 .176
4 .460 .378 .316 .425 .351 .294 .358 .299 .253 .297 .250 .212 .239 .202 .172 .140
5 .398 .319 .258 .370 .296 .240 .313 .252 .206 .258 .209 .172 .208 .169 .138 .110
6 .353 .273 .216 .325 .253 .199 .274 .215 .170 .227 .178 .141 .183 .143 .112 .087
7 .312 .234 .181 .288 .216 .167 .242 .183 .141 .199 .152 .116 .161 .122 .092 .069
8 .279 .204 .152 .257 .189 .142 .217 .161 .120 .180 .133 .099 .144 .106 .077 .056
9 .251 .179 .130 .232 .166 .121 .196 .141 .102 .162 .116 .083 .130 .092 .065 .045
10 .226 .157 .112 .208 .146 .104 .177 .124 .087 .146 .102 .070 .118 .081 .054 .037

Standard Dome

Effective Floor Cavity Reflectance (Rfc) is 20%

% Walls

Rw

80
50

30

70
10

50

30

50
10

50

30

30
10

50

30

10
10

50

30

0
10

0

1 .777 .747 .719 .759 .731 .706 .724 .701 .681 .693 .676 .658 .666 .650 .636 .620

ROOM CAVITY RATIOS

2 .679 .631 .589 .665 .620 .583 .636 .599 .566 .610 .580 .552 .587 .561 .537 .521
3 .593 .534 .486 .581 .525 .481 .557 .510 .471 .535 .495 .461 .514 .480 .451 .435
4 .523 .459 .409 .513 .453 .405 .492 .440 .398 .473 .428 .391 .456 .416 .384 .367
5 .459 .391 .340 .449 .385 .337 .433 .376 .334 .416 .366 .328 .401 .358 .323 .307
6 .406 .337 .289 .397 .333 .285 .382 .325 .282 .368 .317 .278 .356 .310 .274 .259
7 .359 .291 .246 .352 .287 .242 .339 .279 .238 .326 .274 .235 .316 .269 .232 .217
8 .323 .257 .211 .316 .254 .210 .305 .248 .208 .295 .243 .205 .284 .238 .203 .188
9 .291 .227 .182 .286 .223 .182 .275 .219 .180 .266 .214 .178 .257 .210 .175 .161
10 .262 .200 .159 .257 .199 .159 .249 .194 .157 .240 .290 .154 .234 .187 .152 .140

30° Angle
Photometric data shown on this page is based on a 200 Watt A-23 lamp
and is representative of the performance for all Stylmaster incandescent
fixtures. For candlepower values of fixtures with other lamps, multiply the
given candlepower values by the following multipliers: for 75 W A19 – 0.31;
for 100 W A19 – 0.45; for 150 W A21 – 0.75; and for 300 W PS25 – 1.65.
For candlepower values of fixtures with guard, multiply by 0.90.

Lighting

Lighting: Enclosed and Gasketed — Area — Incandescent

% Ceiling Rcc

1134

Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

V-51® Incandescent Luminaires
Enclosed and Gasketed

UNILETS® for use with threaded metal conduit. Fixtures suitable for use in wet locations. ‡
NEC:
Class I, Division 2, Groups A, B, C, D

CSA: V
Class I, Division 2, Groups A, B, C, D
Class II, Divisions 1 and 2, Groups E, F, G †
Class III
Enclosure 3R

Applications
•	 Enclosed and gasketed lighting fixtures for use in storage
areas, tunnels, subways, chemical plants and other areas where
moisture, dirt or corrosive atmospheres are a problem.
•	 Suitable for use in wet locations.
•	 Standard fixtures designed for 60 to 300 W medium base
incandescent lamps.
•	 Available in pendant, 45º stanchion, and a variety of ceiling 	
and wall mountings.

Features

Illustrated Features
Cut-Away View
Connection block is easily removed (loosen
two screws) to permit quick wiring.
Mounting Hood
Available in pendant (shown), ceiling, wall
and 45º stanchion. Pendant has setscrew to
prevent fixture from turning on stem.
Neoprene Ring
Neoprene attachment ring secures reflector to
mounting hood – no tools needed.
Globe Adapter
When adapter is threaded onto mounting
hood, the socket makes electrical contact with
connection block in mounting hood. Available
in malleable iron (VAD-1M and VAD-2M) or
aluminum (VAD-1 and VAD-2).
Porcelain Enamel Reflectors
Standard and 30° angle.

Standard Materials
•	 Mounting hoods: malleable iron or copperfree (4/10 of 1%
max.) aluminum
•	 Globe adapters: malleable iron or pressure cast copperfree
(4/10 of 1% max.) aluminum
•	 Socket: porcelain with brass screw shell
•	 Globes: glass. Optional globes in polycarbonate plastic 	
100 W Max
•	 Guards: steel or pressure cast copperfree (4/10 of 1% max.)
aluminum
•	 Reflectors: porcelain enamel steel

Guard
Two sealed ball plunger units snap quickly,
easily and securely into cavities of globe
adapter. Guard can be used with or without a
reflector.

Standard Finishes
•	 Malleable iron mounting hood and globe adapter: triple coat –
(1) zinc electroplate, (2) chromate, and (3) epoxy powder coat
•	 Aluminum mounting hood, adapter and guard: epoxy powder
coat
•	 Steel guard: zinc electroplate
•	 Steel reflectors: white porcelain enamel
•	 Socket and globes: natural finish

Guard and Reflectors

Lighting: Enclosed and Gasketed — Area — Incandescent

•	 Furnished with connection block for easy wiring.
•	 Unitized construction reduces installation and 	
maintenance costs.
•	 Shock-absorbing porcelain socket for longer lamp life.
•	 Neoprene rubber ring in neck of reflector snaps into groove 	
of mounting hood – protects against vibration and chipping.
•	 Guard snaps into two recesses of adapter – no clamps 	
or setscrews.
•	 Available in three standard fixtures:
(1) V-51 malleable iron mounting hood with aluminum adapter
and guard
(2) all malleable iron (steel guard)
(3) all aluminum
•	 Maximum input voltage 150 V.

Options
•	 To order fixture with other than standard clear glass globe, add
suffix letters to catalog number as indicated in table, and adjust
difference in price.
Glass Globe
-AM
-BL
-GR
-RE
-HR

Plastic Globe
-PAM
-PBL
-PGR
-PRE
—

Lighting

Color
Amber
Blue
Green
Red
Clear Heat-Resistant

Certifications and Compliances
•	
•	
•	
•	

UL Standard: UL 1598, UL 844
UL Listed: E10444
CSA Standard: C22.2 No. 250, C22.2 No. 137
CSA Certified: 025428

† 300 W PS-25 NOT approved for Class II, Division 1 and 2, Group G; Class III.
‡ With heat-resistant glass globes or plastic globes.
V CSA Certification only.
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

1135

V-51® Incandescent Luminaires
Enclosed and Gasketed

UNILETS® for use with threaded metal conduit. Fixtures suitable for use in wet locations. ‡
NEC:
Class I, Division 2, Groups A, B, C, D

CSA: V
Class I, Division 2, Groups A, B, C, D
Class II, Divisions 1 and 2, Groups E, F, G †
Class III
Enclosure 3R

Class I, Division 2, Groups A, B, C, D
Fixture is suitable for Class I, Division 2 where the fixture operating temperature does not exceed the ignition 	
temperature of the atmosphere in which fixture is installed.
“T” Numbers Represent the Maximum Lamp Temperature for Class I, Division 2 Locations
Supply Wire: 257 ºF/125 ºC

“T”
Number

T1

350

325

T2

T2A

T2B

T2C

T2D

T3

T3A

T3B

T3C

T4

T4A

T5

T6

Temp.
Range
(˚ºF)

664842

619662

574617

538572

502536

448500

421446

394419

358392

331356

322329

277320

250275

214248

187212

185

Temp.
Range
(˚ºC)

351450

326350

301325

281300

261280

231260

216230

201215

181200

166180

161165

136160

121135

101120

86-100

85

Class I, Division 2, Groups A, B, C, D

Reflector

200-300 W
PS-25
150 W

PS-30
200 W

PS-30
300 W

None

T3

T2D

T2C

325

Standard Dome

T2D

T2C

T2B

325

30º Angle

T2C

T2C

T2B

325

Fixture Ambient Suitability:
Class I, Division 2, Groups A, B, C, D

Fixture Ambient Suitability:
Class II, Groups E, F, G; Class III; Enclosure 4X

Areas

ºF

ºC

Fixture

Watts

Non-Classified

167

Classified

104

75

A-23

60 to 300

40

PS-30

60 to 300

Lighting

Lighting: Enclosed and Gasketed — Area — Incandescent

60-150 W
A-21
100 W

† 300 W PS-25 not approved for Class II, Division 1 and 2, Group G; Class III.
‡ With heat-resistant glass globes or plastic globes.
V CSA Certification only.

1136

Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

V-51® Incandescent Luminaires
Enclosed and Gasketed

UNILETS® for use with threaded metal conduit. Fixtures suitable for use in wet locations. ‡
NEC:
Class I, Division 2, Groups A, B, C, D

Malleable Mounting
Hood, Aluminum
Adapter and Guard

Malleable Mounting
Hood, Adapter
and Guard

CSA: V
Class I, Division 2, Groups A, B, C, D
Class II, Divisions 1 and 2, Groups E, F, G †
Class III
Enclosure 3R

Type

Lamp
Watts

Size
(Inches)

Malleable Mounting Hood
with Aluminum Guard

Catalog Numbers ①
All Malleable
with Guard

All Aluminum
with Guard

Pendant

A-21

PS-30

60-150

150-300

1/2

VA1050G

VA1050G-M

VA1050G-A

3/4

VA1075G

VA1075G-M

VA1075G-A

1

VA1100G

VA1100G-M

—

1-1/4

VA1125G

VA1125G-M

1/2

VA2050G

VA2050G-M

VA2050G-A

3/4

VA2075G

VA2075G-M

VA2075G-A

1

VA2100G

VA2100G-M

—

1-1/4

VA2125G

VA2125G-M

—

1/2

VXHA1050G

VXHA1050G-M

VXHA1050G-A

3/4

VXHA1075G

VXHA1075G-M

VXHA1075G-A

1

VXHA1100G

VXHA1100G-M

VXHA10100G-A

1/2

VXHA2050G

VXHA2050G-M

VXHA2050G-A

3/4

VXHA2075G

VXHA2075G-M

VXHA2075G-A

1

VXHA2100G

VXHA2100G-M

VXHA20100G-A

—

Ceiling — Five Tapped Openings — Four close-up plugs

PS-30

60-150

150-300

Wall — JB Box Mounting ② — Fits JB cast outlet box ③ — Screws and gasket furnished with fixture
A-21

60-150

PS-30

150-300

JBW10G
JBW20G

JBW10G-M

JBW10G-A

JBW20G-M

JBW20G-A

Lighting: Enclosed and Gasketed — Area — Incandescent

A-21

Ceiling – JB Box Mounting ② — Fits JB cast outlet box ③ — Screws and gasket furnished with fixture
60-150

JB10G

JB10G-M

JB10G-A

PS-30

150-300

JB20G

JB20G-M

JB20G-A

Lighting

A-21

† 300 W PS-25 not approved for Class II, Division 1 and 2, Group G; Class III.
‡ With heat-resistant glass globes or plastic globes.
① To order fixtures without guards, omit G suffix from catalog number. Order reflectors and accessories separately.
② 30º angle reflector adaptable for 100 W fixture only, when mounted at least 4.5”/114.3 mm from wall.
③ JB cast outlet box is available in the Fitting Section.
V CSA Certification only.
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

1137

V-51® Incandescent Luminaires
Enclosed and Gasketed

UNILETS® for use with threaded metal conduit. Fixtures suitable for use in wet locations. ‡
NEC:
Class I, Division 2, Groups A, B, C, D

CSA: V
Class I, Division 2, Groups A, B, C, D
Class II, Divisions 1 and 2, Groups E, F, G †
Class III
Enclosure 3R

Type

Lamp Watts

A21

60-150

PS30

150-300

A21

60-150

PS30

150-300

Size
(Inches)

Catalog Numbers ①
Malleable Mounting Hood
Aluminum Mounting Hood
with Aluminum Guard
and Guard

Feed-Thru
1/2

VC1050G

VC1050G-A

3/4

VC1075G

VC1075G-A

1/2

VC2050G

VC2050G-A

3/4

VC2075G

VC2075G-A

1/2

VT1050G

—

3/4

VT1075G

—

1/2

VT2050G

—

3/4

VT2075G

—

Lighting: Enclosed and Gasketed — Area — Incandescent

Ceiling – Three Hubs

Outlet Box Mounting — For SEH cast outlet box ② or 3-1/4” or 4” octagonal outlet box ③ for non-classified areas only — Gasket
and adapter plate furnished with fixture
A21

60-150

OBV10G

OBV10G-A

PS30

150-300

OBV20G

OBV20G-A

A21

60-150

VX1050G

—

Ceiling – Four Hubs

150-300

3/4

VX1075G

—

1/2

VX2050G

—

3/4

VX2075G

—

Lighting

PS30

1/2

† 300 W PS-25 not approved for Class II, Division 1 and 2, Group G; Class III.
‡ With heat-resistant glass globes or plastic globes.
① To order fixtures without guards, omit G suffix from catalog number. Order reflectors and accessories separately.
② SEH cast outlet box is available in the Fitting Section.
③ Octagonal outlet box is available in the Commercial Fitting Section.
V CSA Certification only.

1138

Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

V-51® Incandescent Luminaires
Enclosed and Gasketed

UNILETS® for use with threaded metal conduit. Fixtures suitable for use in wet locations. ‡
NEC:
Class I, Division 2, Groups A, B, C, D

CSA: V
Class I, Division 2, Groups A, B, C, D
Class II, Divisions 1 and 2, Groups E, F, G †
Class III
Enclosure 3R

Type

Lamp Watts

A21

60-150

PS30

150-300

A21

60-150

PS30

150-300

A21

60-150

Size
(Inches)

Catalog Numbers ①
Malleable Mounting Hood
Aluminum Mounting Hood
with Aluminum Guard
and Guard

Ceiling – Single Hub
1/2

V1050G

V1050G-A

3/4

V1075G

V1075G-A

1/2

V2050G

V2050G-A

3/4

V2075G

V2075G-A

Wall – One Tapped Hub in Flange ②
VGA1050G

—

3/4

VGA1075G

—

1/2

VGA2050G

—

3/4

VGA2075G

—

1/2

VD1050G

—

Lighting: Enclosed and Gasketed — Area — Incandescent

1/2

Wall – Vertical Feed-Thru ②

PS30

150-300

3/4

VD1075G

—

1/2

VD2050G

—

3/4

VD2075G

—

1/2

VGAT1050G

—

3/4

VGAT1075G

VGAT1075G-A

1/2

VGAT2050G

—

3/4

VGAT2075G

VGAT2075G-A

Wall – Three Hubs Plus One Tapped Opening in Center of Flange ②
60-150

PS30

150-300

† 300 W PS-25 not approved for Class II, Division 1 and 2, Group G; Class III.
‡ With heat-resistant glass globes or plastic globes.
① To order fixtures without guards, omit G suffix from catalog number. Order reflectors and accessories separately.
② 30º angle reflector adaptable for 100 W fixture only, when mounted at least 4.5”/114.3 mm from wall.
V CSA Certification only.
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

1139

Lighting

A21

V-51® Incandescent Luminaires
Enclosed and Gasketed

UNILETS® for use with threaded metal conduit. Fixtures suitable for use in wet locations. ‡
NEC:
Class I, Division 2, Groups A, B, C, D

CSA: V
Class I, Division 2, Groups A, B, C, D
Class II, Divisions 1 and 2, Groups E, F, G †
Class III
Enclosure 3R

Type

Catalog Numbers ①
Malleable Mounting Hood
Aluminum Mounting Hood
with Aluminum Guard
and Guard

Lamp Watts

45˚ Stanchion — Reflector not available for this fixture
A21

60-150

1-1/4

—

VMAN10125G-A

PS30

150-300

1-1/4

—

VMAN20125G-A

A21

60-150

OBVW10G

OBVW10G-A

PS30

150-300

OBVW20G

OBVW20G-A

Ceiling – GS Form 20 Box Mounting — Fits GS cast outlet box ③ — Screws and gasket furnished with fixture
A21

60-150

GS102G

—

PS30

150-300

GS202G

—

Wall – GS Box Mounting ② — Fits GSU cast outlet box ③ — Screws and gasket furnished with fixture
A21

60-150

GSW102G

—

PS30

150-300

GSW202G

—

Lighting

Lighting: Enclosed and Gasketed — Area — Incandescent

Wall – Outlet Box Mounting ② — Fits VPJB outlet box, SEH cast outlet box ③ or 3-1/4” or 4” octagonal outlet box ④ for nonclassified areas only — Gasket and adapter plate furnished with fixture

† 300 W PS-25 not approved for Class II, Division 1 and 2, Group G; Class III.
‡ With heat-resistant glass globes or plastic globes.
① To order fixtures without guards, omit G suffix from catalog number. Order reflectors and accessories separately.
② 30º angle reflector adaptable for 100 W fixture only, when mounted at least 4.5”/114.3 mm from wall.
③ Cast outlet boxes are available in the Fitting Section.
④ Octagonal outlet boxes are available in the Commercial Fitting Section.
V CSA Certification only.

1140

Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

V-51® Incandescent Luminaire Accessories
Enclosed and Gasketed

UNILETS® for use with threaded metal conduit.

Catalog Numbers
Description

Hub Size (Inches)

Malleable Iron

Aluminum

Pendant and Ceiling Mounting Hoods — Furnished with connection block, gasket and screws
Pendant Mounting
1/2

VA50

VA50-A

3/4

VA75

VA75-A

1

VA100

—

1-1/4

VA125

—

Dead-End ­— Ceiling Mounting
1/2

V50

V50-A

3/4

V75

V75-A

Feed-Thru — Ceiling Mounting
1/2

VC50

VC50-A

3/4

VC75

VC75-A

Three Hubs — Ceiling Mounting
VT50

—

VT75

—

Lighting: Enclosed and Gasketed — Area — Incandescent

1/2
3/4
Four Hubs — Ceiling Mounting
1/2

VX50

—

3/4

VX75

—

Five Hubs — Ceiling Mounting ①
1/2

VXHA50

VXHA50-A

3/4

VXHA75

VXHA75-A

1

VXHA100

VXHA100-A

Wall and Stanchion Mounting Hoods — Furnished with connection block, gasket and screws
One Opening — Wall Mounting ② — 1 tapped hole in center of flange
1/2

VGA50

—

3/4

VGA75

—

Feed-Thru — Wall Mounting ② — 2 tapped vertical feed-thru hubs
1/2

VD50

—

3/4

VD75

—

Three Hubs and One Opening – Wall Mounting ② — 3 hubs plus 1 tapped opening in
center of flange
VGAT50
VGAT75

—

Lighting

1/2
3/4

VGAT75-A

45° Stanchion Mounting
1-1/4

—

VMAN-125

① Four close-up plugs furnished.
② Mounting hoods for wall installations can only be used with 30º angle reflectors.
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

1141

V-51® Incandescent Luminaire Accessories
Enclosed and Gasketed

UNILETS® for use with threaded metal conduit.

Wall

Ceiling

Catalog Numbers
Malleable Iron
Aluminum

Type

Wall and Ceiling Outlet Box Mounting Hoods
SEH ① and 3-1/4” or 4” Octagonal Outlet Box Mounting ② for Non-Classified Areas Only
Wall ③

OBVW1

OBVW1-A

Ceiling

OBV1

OBV1-A

GS Round Base Outlet Box Mounting – Form 20 ①
Wall ③

GSW2

—

Ceiling

GS2

—

Lighting: Enclosed and Gasketed — Area — Incandescent

JB Round Base Outlet Box Mounting ①

A21

PS30

Type

Wall ③

JBW1

JBW1-A

Ceiling

JB1

JB1-A

Catalog Numbers
Malleable Iron
Aluminum

Lamp Watts

Fixture Units
Adapter/Socket, Globe and Guard
A21

60-150

VU100M

VU-100

PS30

150-300

VU200M

VU-200

Adapter/Socket and Globe
A21

60-150

VU100MLG

VU-100LG

PS30

150-300

VU200MLG

VU-200LG

Lighting

Adapter/Socket
A21

60-150

VAD-1M ④

VAD-1

PS30

150-300

VAD-2M ④

VAD-2

① Cast outlet boxes and gaskets are available in the Fitting Section. Screws, gasket and adapter plate furnished with fixture mounting hood.
② Octagonal outlet boxes are available in the Commercial Fitting Section. Screws, gasket and adapter plate furnished with fixture mounting hood.
③ Mounting hoods for wall installations can only be used with 30º angle reflectors.
④ Accepts steel wire guard only

1142

Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

V-51® Incandescent Luminaire Accessories
Enclosed and Gasketed

UNILETS® for use with threaded metal conduit.

Type

Lamp Watts

Catalog Numbers
Glass — 60-150 W
Polycarbonate ­‑ 100 W Max. ①

Glass and Polycarbonate Globes — 60-150 W

60 W-150 W Glass

100 W Polycarbonate

Clear

VGL-1CL

VPG-1CL

Amber

VGL-1AM

VPG-1AM

Blue

VGL-1BL

VPG-1BL

Green

VGL-1GR

VPG-1GR

Opal

VGL-1OP

Red

VGL-1RE

Clear Heat-Resistant

VGL-1HR

—

—
VPG-1RE

Glass Globes — 150-300W
VGL-2CL

—

VGL-2AM

—
—

Blue

VGL-2BL

Green

VGL-2GR

—

Opal

VGL-2OP

—

Red

VGL-2RE

—

Clear Heat-Resistant

VGL-2HR

—

Lighting: Enclosed and Gasketed — Area — Incandescent

Clear
Amber

Aluminum Guards ②
A21

③

60-150

VGU-1

PS30

④

150-300

VGU-2

A21

⑤

60-150

VWG-1

PS30

⑥

150-300

VWG-2

VGU-2
Steel Wire Guards ②

Lighting

VWG-1

① Do not use in ambients exceeding 77 ºF/25º C. For burning in base-up position only.
② Cannot be used with polycarbonate globes.
③ Fits VAD-1 Adapter)
④ Fits VAD-2 Adapter)
⑤ Fits VAD-1M Adapter)
⑥ Fits VAD-2M Adapter)
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

1143

V-51® Incandescent Luminaire Accessories
Enclosed and Gasketed

UNILETS® for use with threaded metal conduit.

Description

Type

Lamp Watts

Catalog Number

Porcelain Reflectors — Furnished with neoprene attaching ring
Standard Dome
A21

60-150

VRW-1ST

PS30

150-300

VRW-2ST

A21

60-150

VRW-1AN

PS30

150-300

VRW-2AN

30˚ Angle

Lighting: Enclosed and Gasketed — Area — Incandescent

Replacement Reflector Attaching Ring — Neoprene
VPT-8
Connection Block
VPT-7
Lamp Socket — Medium Base

VPT-1AV

Gasket for Lamp Socket and 60-150 W Globe

VPT-2

Gasket for 150-300 W Globe

Lighting

VPT-3

Gasket for Mounting Hood

VPT-4

1144

Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

V-51® Incandescent Luminaire Dimensions
Enclosed and Gasketed

UNILETS® for use with threaded metal conduit.

Dimensions in Inches/Millimeters
5.19"/
131.8 mm
3.81"/
96.8mm

3.81"/
96.8 mm

4.44"/
112.8 mm

Types V, VC, VT and VX

Type VXHA

3.50"/
88.9 mm
2.38"/
60.5 mm

2.63"/
66.8 mm

2.63"/
66.8 mm

3.00"/
76.2 mm
0.94"/
23.9 mm

Types OBV and OBVW

3.50"/
12.7mm

4.50"/
114.3 mm

4.00"/
101.6 mm
4.00"/
101.6 mm

3.06"/
77.7 mm

3.50"/
12.7mm
4.63"/
117.6 mm

4.00"/
101.6 mm

2.19"/
55.6 mm

4.63"/
117.6 mm

0.75"/
19.1 mm

Types VGA and VGAT

Type VD

Types JB and JBW

Types GS and GSW

Size

A

B

C

1/2 & 3/4
D

1 & 1-1/4
D

60-150 W

6.38/162.1

5.75/146.1

4.19/106.4

2.63/66.8

2.89/73.4

150-300 W

9.50/241.3

8.63/219.2

5.69/144.5

2.63/66.8

2.89/73.4

Reflectors

Lighting: Enclosed and Gasketed — Area — Incandescent

4.50"/
114.3 mm

5.00"/
127 mm

2.75"/
69.9 mm

2.19"/
55.6 mm

Type VA

3.50"/
12.7mm
5.00"/
127 mm

Lighting

Standard Dome

30˚ Angle

Standard Dome

30˚ Angle

Size

A

B

A

B

60-150 W

6.19/157.2

12.00/304.8

8.09/205.5

10.00/254.0

150-300 W

8.88/225.6

16.00/406.4

11.59/294.4

12.00/304.8

Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

1145

V-51® Incandescent Luminaire Photometric Data
Enclosed and Gasketed

UNILETS® for use with threaded metal conduit. Full-size photometric data available for all V-51® fixtures on request.

Without Reflector

Effective Floor Cavity Reflectance (Rfc) is 20%
% Ceiling Rcc
% Walls

Rw

80
50

30

70
10

50

30

50
10

50

30

30
10

50

30

10
10

50

30

0
10

0

1 .815 .765 .721 .755 .711 .668 .642 .608 .577 .539 .513 .489 .444 .424 .406 .360

ROOM CAVITY RATIOS

2 .690 .619 .558 .639 .575 .521 .542 .492 .449 .452 .414 .380 .370 .341 .315 .273
3 .595 .515 .450 .551 .478 .421 .467 .410 .362 .388 .344 .307 .316 .282 .252 .215
4 .523 .439 .374 .485 .409 .350 .411 .351 .303 .343 .296 .257 .279 .242 .212 .178
5 .457 .376 .313 .426 .350 .292 .362 .300 .254 .302 .253 .215 .246 .208 .177 .147
6 .409 .326 .266 .378 .303 .248 .322 .261 .215 .269 .220 .183 .220 .180 .150 .123
7 .364 .283 .229 .338 .264 .213 .288 .226 .184 .240 .192 .155 .198 .158 .128 .104
8 .329 .251 .197 .305 .234 .185 .260 .202 .160 .220 .171 .136 .179 .141 .112 .090
9 .298 .223 .171 .277 .208 .161 .237 .180 .140 .199 .152 .119 .164 .126 .098 .078
10 .271 .198 .152 .251 .187 .142 .216 .161 .123 .182 .137 .104 .151 .113 .086 .068
Effective Floor Cavity Reflectance (Rfc) is 20%
% Ceiling Rcc
% Walls

Rw

80
50

30

70
10

50

30

50
10

50

30

30
10

50

30

10
10

50

30

0
10

0

1 .803 .772 .744 .784 .756 .731 .750 .726 .706 .718 .701 .683 .691 .675 .661 .645

ROOM CAVITY RATIOS

2 .705 .656 .614 .690 .645 .608 .661 .624 .591 .636 .605 .576 .612 .586 .562 .546
3 .618 .558 .511 .606 .550 .506 .583 .535 .495 .560 .520 .486 .540 .506 .476 .460
4 .549 .484 .434 .538 .478 .430 .518 .465 .423 .499 .454 .417 .482 .442 .410 .393
5 .485 .416 .366 .475 .411 .363 .459 .401 .359 .442 .392 .354 .427 .384 .349 .333
6 .431 .362 .314 .423 .358 .310 .408 .350 .307 .394 .343 .304 .382 .335 .299 .284
7 .384 .316 .270 .377 .311 .267 .364 .304 .263 .351 .299 .260 .341 .294 .257 .242
8 .347 .281 .234 .340 .278 .233 .329 .272 .231 .319 .267 .229 .309 .262 .226 .212
9 .314 .249 .204 .309 .246 .204 .299 .242 .202 .289 .237 .200 .281 .233 .198 .184
10 .284 .221 .181 .279 .221 .181 .271 .216 .179 .263 .212 .176 .257 .209 .174 .161

30° Angle
Photometric data shown on this page is based on a 150 Watt PS-25 lamp
and is representative of the performance for all V-51 incandescent fixtures.
For candlepower values of fixtures with other lamps, multiply the given
candlepower values by the following multipliers: for 60 W – A19 X 0.33; for
75 W – A19 X 0.45; for 100 W – A19 X 0.66; for 200 W – PS25 X 1.44; and
for 300 W – PS30 X 2.32. For candlepower values of fixture with guard,
multiply by 0.90.

Lighting

Lighting: Enclosed and Gasketed — Area — Incandescent

Standard Dome

1146

Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

REA™ 150 W Incandescent Luminaires ①
Enclosed and Gasketed

UNILETS® for use with Threaded Metal Conduit. Medium Base. Inexpensive, Low Wattage Fixture for use in Wet Locations.

Applications
•	 Vaportight enclosed and gasketed lighting fixtures, suitable for
use in wet locations.
•	 Standard glass globes take up to 150 W A-21 lamps. Optional
polycarbonate plastic globes take up to 100 W A-21 lamps.

Features
•	 Inexpensive fixture designed for use without reflector.
•	 Spring-mounted shock-absorbing socket prolongs lamp life.
•	 Guards snap on easily and securely. Spring-action balls snap
into detents in fixture body.

Standard Materials
•	 Mounting bodies: pressure cast copperfree (4/10 of 1% max.)
aluminum
•	 Socket: porcelain with brass screw shell
•	 Guards: steel or aluminum guards

Standard Finishes

Pendant

Mounting bodies: burnished
Steel wire guard: zinc electroplate
Aluminum guard: aluminum polymer enamel
Socket and globes: natural finish

Outlet Box

Wall

Lighting: Enclosed and Gasketed — Area — Incandescent

•	
•	
•	
•	

Certifications and Compliances
•	 UL Standard: UL 1598

Dimensions in Inches/Millimeters
3.19"/
81.0 mm

3.50"/
12.7 mm
4.19"/
106.4 mm

8.25"/
209.6 mm

11.81"/
300.0 mm

6.38"/
162.1 mm

Lighting

3.94"/
100.1 mm

Pendant

3.75"/
96.3 mm

3.94"/
100.0 mm

Outlet Box

Wall

① Maximum size A-21 lamp: glass globe – 150 Watts; plastic globe – 100 Watts. No reflectors are available for REA fixtures.
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

1147

REA™ 150 W Incandescent Luminaires ①
Enclosed and Gasketed

UNILETS® for use with Threaded Metal Conduit. Medium Base. Inexpensive, Low Wattage Fixture for use in Wet Locations.

Description

Hub Size
(Inches)

Catalog Number

1/2
3/4

REA-1050
REA-1075

Pendant Fixture

Pendant

Outlet Box

Outlet Box Fixture
For 3-1/4” or 4” octagonal, or 4” square mounting.

REA-10B

Wall Fixture
REA-10LB

Wall
Pendant Hood

Lighting: Enclosed and Gasketed — Area — Incandescent

1/2
3/4

REA-50
REA-75

Wall Bracket
1/2 male stem

REA-1BR

Lamp Socket
VPLR-123
Steel Guard
VWG-1

For Outlet Box fixture only.
Aluminum Guard
For Pendant and Wall Mount fixtures only.
VWG-1

VGU-1

VGU-1

Catalog Number ①
Glass
Plastic

Description

Lighting

Colored Glass and Polycarbonate Globes

Glass

Plastic

Clear

VGL-1CL

VPG-1CL

Amber

VGL-1AM

VPG-1AM

Blue

VGL-1BL

VPG-1BL

Green

VGL-1GR

VPG-1GR

Opal

VGL-1OP

—

Red

VGL-1RE

VPG-1RE

Clear Heat-Resistant

VGL-1HR

—

① Maximum size A-21 lamp: glass globe – 150 Watts; plastic globe – 100 Watts. No reflectors are available for REA fixtures.

1148

Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

Areamaster™ 100 Wide-Beam Floodlights
70 W, 100 W, 150 W HPS; 70 W, 100 W, 150 PSMH
For general, marine and hazardous locations.
NEC
Class I, Division 2, Groups A, B, C, D
Marine type electric fixtures, outside type
(salt water)

CEC V
Class I, Division 2, Groups A, B, C, D
Class II, Divisions I and 2, Groups E, F, G V
Class III
Marine type electric fixtures, outside type
(salt water)

Applications
•	 Highly efficient, all-weather flood-lighting for lower wattage
service. Well suited for:
	 — Facades
	 — Amusement and recreational areas
	 — Parking lots
	 — Industrial and marine use

Features
•	 Ruggedly built for dependable, vandal resistant service.
Attractively styled. Easy to install, aim, add service, with easy
access to spacious interior.
.•	 Integral ballast.
•	 One-piece housing.
•	 One-piece lens cover. Secured by four 1/4” dia. captive
stainless steel slotted hex-head bolts.
•	 Thermal shock and impact resistant glass lens.
•	 Heavy duty, high temperature silicone rubber gasket, firmly
seated.
•	 Heavy duty mogul-base porcelain socket with heavy gauge
brass, nickel-plated, double lamp-grip screw shell and springloaded center contact.
•	 Parabolic finished aluminum reflector for optimum efficiency.
•	 Mounting choice:
(1) Yoke mount, zinc plated steel yoke with architectural bronze
polyester finish
(2) Pole mount, built-in slip-fitter, for internal wiring, adjustable
laterally and vertically, slip fits 2” or 2-1/2” pipe, architectural
bronze polyester finish

Yoke Mount

Standard Materials
•	 Ballast housing and lens cover: copperfree (4/10 of 1% max.)
aluminum
•	 Gasket: silicone rubber
•	 Socket: heavy duty porcelain with heavy gauge brass shell
•	 Reflector: finished aluminum
•	 Yoke mount: zinc plated steel
•	 Bolts: stainless steel

Pole Mount

Lighting: Enclosed and Gasketed — Floodlight

Standard Finishes
•	 Ballast housing, lens cover, yoke and pole mount: architectural
bronze polyester
•	 Socket: nickel-plated

Certifications and Compliances
•	 UL Standard: UL 1598, UL 1598A, UL 844
•	 UL Listed: E10794
•	 CSA Certified: LR25428

Lighting

V CSA Certification only.
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

1149

Areamaster™ 100 Wide-Beam Floodlights
70 W, 100 W, 150 W HPS

For general, marine and hazardous locations.
NEC
Class I, Division 2, Groups A, B, C, D
Marine type electric fixtures, outside type
(salt water)

Yoke Mount

Pole Mount

Lamp Watts

Lamp Type

70

HPS

120/208/240/277

G-AM271L-MT-I/2

G-AM271L-MT

G-AM275L-MT

70

HPS

480

G-AM271L-48-I/2

G-AM271L-48

G-AM275L-48

100

HPS

120/208/240/277

G-AM371L-MT-I/2

G-AM371L-MT

G-AM375L-MT

100

HPS

480

G-AM371L-48-I/2

G-AM371L-48

G-AM375L-48

150

HPS

120/208/240/277

G-AM471L-MT-I/2

G-AM471L-MT

G-AM475L-MT

150

HPS

480

G-AM471L-48-I/2

G-AM471L-48

G-AM475L-48

Lighting

Lighting: Enclosed and Gasketed — Floodlight

Electrical Specifications
Line
Type of
Starting
Voltage
Ballast
Amps
70 Watt High Pressure Sodium
120
HX-HPR
0.90
208
HX-HPR
0.50
240
HX-HPR
0.44
277
HX-HPR
0.35
480
HX-HPR
0.21
100 Watt High Pressure Sodium
120
HX-HPR
1.30
208
HX-HPR
0.76
240
HX-HPR
0.66
277
HX-HPR
0.60
480
HX-HPR
0.33
150 Watt High Pressure Sodium
120
HX-HPR
2.00
208
HX-HPR
1.16
240
HX-HPR
1.00
277
HX-HPR
0.85
480
HX-HPR
0.50

Marine Yoke Mount ➊ for
Class I, Division 2 Classified Duty

Catalog Number
Yoke Mount ➊
for General Duty

Line
Voltages

Slip-Fit Mount ➋

T Numbers and Temperature Ratings of “Classified Duty”
Operating
Amps

Total
Watts

0.82
0.48
0.41
0.36
0.21

94
94
94
94
94

1.15
0.67
0.60
0.52
0.31

130
130
130
130
135

1.70
0.95
0.85
0.72
0.47

188
188
188
188
188

Lamp
Watts
70
100
150

T Rating
T3
T2C
T2

Ambient
Temperature (°F/°C)
104/40
104/40
104/40

T Rating Temperature
Range (°F/°C)
358-392/181-200
421-446/216-230
538-572/281-300

➊ Adjustable yoke mounts directly or with adapters.
➋ Internally wired, adjustable slip-fit mount for 2” or 2-1/2” pipe.

1150

Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

Areamaster™ 100 Wide-Beam Floodlights V
70 W, 100 W, 150 W HPS; 70 W, 100 W, 150 PSMH
For general, marine and hazardous locations.

CEC V
Class I, Division 2, Groups A, B, C, D
Class II, Divisions I and 2, Groups E, F, G V
Class III
Marine type electric fixtures, outside type
(salt water)

Catalog Number

Lamp
Watts

Yoke Mount

Slip-Fit

Lamp
Type

Marine Yoke Mount ➊
Class I, Division 2,
Class II, Division 1 & 2
Class III

Line
Voltages

Yoke Mount ➊
for General Duty

Slip-Fit Mount ➋
Class I, Division 2

Slip-Fit
Mount ➋

70

HPS 120/208/240/277 G-AM271L-MT-I/2CN

G-AM271L-MTCN

G-AM275L-MT-I/2CN G-AM275L-MTCN

70

HPS

G-AM271L-TT-I/2CN

G-AM271L-TTCN

G-AM275L-TT-I/2CN

100

HPS 120/208/240/277 G-AM371L-MT-I/2CN

G-AM371L-MTCN

G-AM375L-MT-I/2CN G-AM375L-MTCN

100

HPS

G-AM371L-TT-I/2CN

G-AM371L-TTCN

G-AM375L-TT-I/2CN

150

HPS 120/208/240/277 G-AM471L-MT-I/2CN

G-AM471L-MTCN

G-AM475L-MT-I/2CN G-AM475L-MTCN

150

HPS

G-AM471L-TT-I/2CN

G-AM471L-TTCN

G-AM475L-TT-I/2CN

120/277/347

120/277/347

120/277/347

G-AM275L-TTCN

G-AM375L-TTCN

G-AM475L-TTCN

70

PSMH 120/208/240/277 G-AM271H-MT-I/2CN

G-AM271H-MTCN

G-AM275H-MT-I/2CN G-AM275H-MTCN

70

PSMH

G-AM271H-TT-I/2CN

G-AM271H-TTCN

G-AM275H-TT-I/2CN G-AM275H-TTCN

100

PSMH 120/208/240/277 G-AM371H-MT-I/2CN

G-AM371H-MTCN

G-AM375H-MT-I/2CN G-AM375H-MTCN

100

PSMH

G-AM371H-TT-I/2CN

G-AM371H-TTCN

G-AM375H-TT-I/2CN G-AM375H-TTCN

150

PSMH 120/208/240/277 G-AM471H-MT-I/2CN

G-AM471H-MTCN

G-AM475H-MT-I/2CN G-AM475H-MTCN

150

PSMH

G-AM471H-TT-I/2CN

G-AM471H-TTCN

G-AM475H-TT-I/2CN G-AM475H-TTCN

120/277/347

120/277/347

120/277/347

Operating
Amps

Total
Watts

0.82
0.48
0.41
0.36
0.30
0.21

94
94
94
94
94
94

1.15
0.67
0.60
0.52
0.39
0.31

130
130
130
130
130
135

1.70
0.95
0.85
0.72
0.56
0.47

188
188
188
188
188
188

Line
Type of
Starting
Voltage
Ballast
Amps
70 Watt Pulse Start Metal Halide
120
HX-HPF
0.80
208
HX-HPF
0.50
240
HX-HPF
0.43
277
HX-HPF
0.39
347
HX-HPF
0.20
480
HX-HPF
0.26
100 Watt Pulse Start Metal Halide
120
HX-HPF
1.20
208
HX-HPF
0.70
240
HX-HPF
0.61
277
HX-HPF
0.55
347
HX-HPF
0.40
480
HX-HPF
0.30
150 Watt Pulse Start Metal Halide
120
HX-HPF
1.75
208
HX-HPF
1.30
240
HX-HPF
0.85
277
HX-HPF
0.77
347
Super C.W.A.
0.65
480
Super C.W.A.
0.45

Operating
Amps

Total
Watts

0.85
0.52
0.44
0.39
0.28
0.23

95
95
95
95
88
95

1.15
0.70
0.58
0.50
0.40
0.35

130
130
130
130
129
140

1.60
1.00
0.80
0.70
0.55
0.42

188
188
188
188
185
185

T Numbers and Temperature Ratings of “Classified Duty”
Lamp Watts
70
100
150

T Rating
T3
T2C
T2

Ambient Temperature (°F/°C)
104/40
104/40
104/40

T Rating Temperature Range (°F/°C)
358-392/181-200
421-446/216-230
538-572/281-300

Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

Lighting

➊ Adjustable yoke mounts directly or with adapters.
➋ Internally wired, adjustable slip-fit mount for 2” or 2-1/2” pipe.
V CSA Certification only.

Lighting: Enclosed and Gasketed — Floodlight

Electrical Specifications
Line
Type of
Starting
Voltage
Ballast
Amps
70 Watt High Pressure Sodium
120
HX-HPR
0.90
208
HX-HPR
0.50
240
HX-HPR
0.44
277
HX-HPR
0.35
347
HX-HPF
0.30
480
HX-HPR
0.21
100 Watt High Pressure Sodium
120
HX-HPR
1.30
208
HX-HPR
0.76
240
HX-HPR
0.66
277
HX-HPR
0.60
347
HX-HPF
0.45
480
HX-HPR
0.33
150 Watt High Pressure Sodium
120
HX-HPR
2.00
208
HX-HPR
1.16
240
HX-HPR
1.00
277
HX-HPR
0.85
347
HX-HPF
0.52
480
HX-HPR
0.50

1151

Areamaster™ 100 Wide-Beam Floodlights
70 W, 100 W, 150 W HPS; 70 W, 100 W, 150 PSMH
For general, marine and hazardous locations.

Mounting Fittings and Accessories
Description

Catalog Number
G-AM-8-CA

Pipe or Wall Mount Bracket — Used with G-AM-8-CA. Clamps to 1” to 2-1/2”
pipe, vertical or horizontal, or mounts on flat surfaces. Includes U-bolt and crossarm
bracket bolts. Malleable iron, zinc plated, chromate sealed, with architectural bronze
polyester finish.

G-AM-8-WB

Poletop Slip-Fitter — 1-1/2” or 2” pipe size poletop tenons. Includes floodlight
yoke bolt, 3 locking bolts, and cord grip. Body is malleable iron—zinc plated,
chromate sealed, with cast aluminum cap. Assembly has architectural bronze
polyester finish.

G-SF20

Locking-Type Photocontrol Receptacle — For NEMA type photocontrol, with
installation hardware and instructions. Should not be mounted on Class I Division 2
units.

G-1PCR

Vandal Shield — UV stabilized polycarbonate, with installation hardware and
instructions.

G-AM-2-VS

Wire Guard — Mounts to lens door with screws furnished. Zinc plated.

G-AM-2-G

Top Visor — Easy to install with hardware supplied. Aluminum, with architectural
bronze polyester finish.

G-AM-2-V

Lighting

Lighting: Enclosed and Gasketed — Floodlight

Crossarm Mounting Bracket — Has 180° horizontal adjustment—degree-marked.
Facilitates mounting floodlight to crossarm or other flat surface, or to G-AM-8-WB. 	
Includes floodlight yoke bolts. Malleable iron, zinc plated, chromate sealed,
architectural bronze POLYESTER finish.

1152

Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

Areamaster™ 100 Wide-Beam Floodlight Dimensions
70 W, 100 W, 150 W HPS; 70 W, 100 W, 150 PSMH
For general, marine and hazardous locations.

Yoke Mount

Pipe or Wall Mount Bracket

Wire Guard

Lighting: Enclosed and Gasketed — Floodlight

Crossarm Mounting Bracket

Pole Mount

Poletop Slip-Fitter

Top Visor

Lighting

Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

1153

Areamaster™ 100 Wide-Beam Floodlight Photometric Data
70 W, 100 W, 150 W HPS; 70 W, 100 W, 150 PSMH
For general, marine and hazardous locations.

Catalog Number

G-AM471L-MT

G-AM371L-MT

G-AM271L-MT

Lamp

Photometric Data

Watts
Lumens
Bulb
Light Center Lgth.
Base

150
16,000
E-23-1/2 Clear
5”
Mogul Screw

Watts
Lumens
Bulb
Light Center Lgth.
Base

100
9500
E-23-1/2 Clear
5”
Mogul Screw

Watts
Lumens
Bulb
Light Center Lgth.
Base

70
5800
E-23-1/2 Clear
5”
Mogul Screw

Total Footcandle Value ‡
150 Watt High Pressure Sodium - Clear 16,000 Lumens

Lighting: Enclosed and Gasketed — Floodlight

141°
115°
8148
50.9%
5155
8552
53.5%
141°
115°
4838
50.9%
3061
5062
53.3%
141°
113°
2982
51.4%
2025
3124
53.9%

Footcandles for Iso-FTC Lines
Ratio of Distance to Height
1.50 C 2.00 D 2.50 E

Lamp Mounting
Watts Height (Ft/M) 0.63 A

1.00 B

10/3.0

31.25

18.23

8.06

3.41

1.63

0.86

0.38

20/6.1

7.81

4.56

2.02

0.85

0.41

0.22

0.10

150

Lighting

Horizontal Spread
Vertical Spread
Beam Lumens
Beam Efficiency
Max. CP.
Total Lumens
Total Efficiency
Horizontal Spread
Vertical Spread
Beam Lumens
Beam Efficiency
Max. CP.
Total Lumens
Total Efficiency
Horizontal Spread
Vertical Spread
Beam Lumens
Beam Efficiency
Max. CP.
Total Lumens
Total Efficiency

100

70

3.00 F

3.75 G

30/9.1

3.47

2.03

0.90

0.38

0.18

0.10

0.04

10/3.0

18.44

10.76

4.76

2.01

0.96

0.51

0.22

20/6.1

4.61

2.69

1.19

0.50

0.24

0.13

0.06

30/9.1

2.05

1.20

0.53

0.22

0.11

0.06

0.02

10/3.0

11.25

6.56

2.90

1.23

0.59

0.31

0.14

20/6.1

2.81

1.64

0.73

0.31

0.15

0.08

0.04

30/9.1

1.25

0.73

0.32

0.14

0.06

0.04

0.01

‡ Photometric charts available upon request.
* (i.e. ratio of distance to height. Example: @ 15'/4.6 m mounting height, 1 means 15'/4.6 m, 2 means 30'/9.1 m, etc.)

1154

Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

Areamaster™ 250/400 Integrally Ballasted Floodlights

70 W, 100 W, 150 W, 250 W, 400 W HPS; 175 W, 200 W, 250 W, 320 W, 400 W PSMH.
175 W, 250 W, 400 W MH V
NEC: For general, marine and hazardous
locations
Class I, Division 2, Groups A, B, C, D
Class I, Zone 2, AEx nR, Groups IIA, IIB, IIC

CEC V: For general, marine and hazardous
locations
Class I, Division 2, Groups A, B, C, D
Class I, Zone 2, Ex nR, Groups IIA, IIB, IIC
Class II, Division 1 and 2, Groups E, F, G
Class III

NEC/CEC:
IP66
Marine type electric fixtures, outside type
(salt water)

Applications
•	 Powerful, efficient weatherproof lighting for medium and large
areas such as:
— Shopping malls
— Parking lots
— Sports areas
— New-car lot lighting
— Security lighting
— Industrial process lighting

Features
•	 Compact in size, attractively styled contemporary design,
rugged and dependable.
•	 Easy to install and service.
•	 A wide range of ballasts and voltages are available for both
domestic and export applications.
•	 Integral ballast.
•	 One-piece housing.
•	 One-piece lens cover. Secured by four  1/4” Dia. captive
stainless steel slotted hex-head bolts.
•	 Thermal shock and impact resistant glass lens.
•	 Heavy duty, high temperature silicone rubber gasket, firmly
seated.
•	 Heavy duty mogul-base porcelain socket with heavy gauge
brass, nickel-plated, double lamp-grip screw shell and springloaded center contact.
•	 Compound parabolic, double segment, finished aluminum
reflector for optimum efficiency.
•	 Mounting choice:
(1) Yoke mount, zinc plated steel yoke with architectural bronze
polyester finish
(2) Pole mount, built-in slip-fitter, for internal wiring, adjustable
laterally and vertically, slip fits 2” or 2-1/2” pipe, architectural
bronze polyester finish
•	 Cool operating temperatures translate into long luminaire life.

Projected Area: 1.9 Sq. Ft.

Dimensions in Inches/Millimeters

Standard Materials

Lighting: Enclosed and Gasketed — Floodlight

•	 Ballast housing and lens door: copperfree (4/10 of 1% max.)
aluminum
•	 Gasket: silicone rubber
•	 Socket: heavy duty porcelain with heavy gauge brass shell
•	 Reflector: finished aluminum
•	 Yoke mount: zinc plated steel
•	 Bolts: stainless steel

Standard Finishes
•	 Ballast housing, lens cover, yoke and pole mount: architectural
bronze polyester
•	 Socket: nickel-plated

Certifications and Compliances
•	
	
	
•	
	

Areamaster 250/400
— UL Standard: UL 1598, UL 1598A, UL 844
— UL Listed: E10794
Zone 2 Areamaster 250/400
— UL Standard: UL 1598, UL 1598A, UL 60079-0, 	
UL 60079-15
	 — UL Listed: E10794

Lighting

V CSA Certification only.
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

1155

Areamaster™ 250/400 Integrally Ballasted Floodlights

70 W, 100 W, 150 W, 250 W, 400 W HPS; 175 W, 200 W, 250 W, 320 W, 400 W PSMH.
175 W, 250 W, 400 W MH V
NEC: For general, marine and hazardous
locations
Class I, Division 2, Groups A, B, C, D
Class I, Zone 2, AEx nR, Groups IIA, IIB, IIC

NEC/CEC:
IP66
Marine type electric fixtures, outside type
(salt water)

CEC V: For general, marine and hazardous
locations
Class I, Division 2, Groups A, B, C, D
Class I, Zone 2, Ex nR, Groups IIA, IIB, IIC
Class II, Division 1 and 2, Groups E, F, G
Class III

“T” Numbers

Lighting

Lighting: Enclosed and Gasketed — Floodlight

Lamp
Watts

Type

70

HPS

100

HPS

150

HPS

250

HPS

400

HPS

175

PSMH

200

PSMH

250

PSMH

320

PSMH

400

PSMH

Supply Wire Temp.
(°F/°C)
140/60
167/75
194/90
167/75
194/90
221/105
185/85
221/105
230/110
167/75
194/90
221/105
221/105
257/125
194/90
221/105
230/110
167/75
185/85
221/105
185/85
221/105
230/110
185/85
221/105
221/105
239/115

NEC/CEC
Class I, Division 2,
Groups A, B, C, D
T3C
T3B
T3A
T3
T2D
T2C
T2C
T2B
T2B
350
350
T1
T1
—
T2
325
325
325
325
325
325
325
—
325
325
325
325

Ambient Temp.
(°F/°C)
104/40
131/55
149/65
104/40
131/55
149/65
104/40
131/55
149/65
104/40
131/55
149/65
104/40
122/50
104/40
131/55
149/65
104/40
131/55
149/65
104/40
131/55
149/65
104/40
131/55
104/40
131/55

CEC V
Class II, Division 1
and 2, Groups E, F, G
T3B
—
—
T3B
—
—
T3B
—
—
T3B
—
—
T3B
—
T3B
—
—
T3B
—
—
T3B
—
—
T3B
—
T3B
—

NEC/CEC
Class I, Zone 2
T6
T5
T4
T5
T4
T4
T4
T4
T3
T4
T3
T3
T3
T3
T4
T3
T3
T3
T3
T3
T3
T3
T3
T3
T3
T3
T3

“T” Numbers Represent the Maximum Lamp Temperature for Class I, Division 2 Locations and
Maximum Surface Temperature Under Dust Blanket for Class II, Division 1 Locations.
“T”
Number

T1

350

325

T2

T2A

T2B

T2C

T2D

T3

T3A

T3B

T3C

T4

T4A

T5

T6

Temp.
Range
(˚ºF)

664842

619662

574617

538572

502536

448500

421446

394419

358392

331356

322329

277320

250275

214248

187212

185

Temp.
Range
(°C)

351450

326350

301325

281300

261280

231260

216230

201215

181200

166180

161165

136160

121135

101120

86100

85

“T” Numbers Represent the Maximum Surface Temperature for Luminaries with AEx nA nR or AEx nR rating
“T” Number

T1

T2

T3

T4

T5

T6

Temp. Range (°F)

547-842

394-572

277-392

214-275

187-212

185

Temp. Range (°C)

301-450

201-300

136-200

101-135

86-100

85

V CSA Certification only.

1156

Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

Areamaster™ 250/400 Integrally Ballasted Floodlights

70 W, 100 W, 150 W, 250 W, 400 W HPS; 175 W, 200 W, 250 W, 320 W, 400 W PSMH
NEC: For general, marine and hazardous
locations
Class I, Division 2, Groups A, B, C, D
Class I, Zone 2, AEx nR, Groups IIA, IIB, IIC
IP66

Line
Voltage

Marine type electric fixtures, outside type
(salt water)

For Class 1, Division 2
Classified Duty and
Marine Yoke Mount
Catalog Number ➋➌

For General Duty

Class I, Zone 2
Yoke Mounting
Catalog Number ➌

Yoke Mount
Catalog Number ➋

Slip-Fit Mount
Catalog Number ➊➋

G-AML271L-MT-I/2

—

—

G-AML271L-MT-Z2

G-AML271L-225-I/2 ➎

—

—

G-AML271L-225-Z2 ➎

480

G-AML271L-48-I/2

—

—

G-AML271L-48-Z2

120/208/240/277

G-AML371L-MT-I/2

—

—

G-AML371L-MT-Z2

Lamp
High Pressure Sodium

120/208/240/277
70 W HPS ➍

100 W HPS ➍

150 W HPS ➍

250 W HPS

400 W HPS

220 V 50 Hz

220 V 50 Hz

G-AML371L-225-I/2 ➎

—

—

G-AML371L-225-Z2 ➎

480

G-AML371L-48-I/2

—

—

G-AML371L-48-Z2

120/208/240/277

G-AML471L-MT-I/2

—

—

G-AML471L-MT-Z2

G-AML471L-225-I/2 ➎

—

—

G-AML471L-225-Z2 ➎

—

G-AML471L-48-Z2

220 V 50 Hz
480

G-AML471L-48-I/2

120/208/240/277

G-AM671L-MT-I/2

G-AM671L-MT

G-AM675L-MT

G-AM671L-MT-Z2

230 V 50 Hz

—

G-AM671L-235-I/2 ➎

G-AM671L-235 ➎

G-AM675L-235 ➎

G-AM671L-235-Z2 ➏

480

G-AM671L-48-I/2

G-AM671L-48

G-AM675L-48

G-AM671L-48-Z2

120/208/240/277

G-AM771L-MT-I/2

G-AM771L-MT

G-AM775L-MT

G-AM771L-MT-Z2

G-AM771L-235-I/2 ➏

G-AM771L-235 ➏

G-AM775L-235 ➏

G-AM771L-235-Z2 ➏

480

G-AM771L-48-I/2

G-AM771L-48

G-AM775L-48

G-AM771L-48-Z2

120/208/240/277

G-AM571P-MT-I/2

G-AM571P-MT

G-AM575P-MT

G-AM571P-MT-Z2

480

230 V 50 Hz

Pulse Start Metal Halide
175 W PSMH
200 W PSMH

G-AM571P-48

G-AM575P-48

G-AM571P-48-Z2

G-AM2071P-MT-I/2

G-AM2071P-MT

G-AM2075P-MT

G-AM2071P-MT-Z2

480

G-AM2071P-48-I/2

G-AM2071P-48

G-AM2075P-48

G-AM2071P-48-Z2

120/208/240/277

G-AM671P-MT-I/2

G-AM671P-MT

G-AM675P-MT

G-AM671P-MT-Z2

G-AM671P-235-I/2 ➏

G-AM671P-235 ➏

G-AM675P-235 ➏

G-AM671P-235-Z2 ➏

G-AM671P-48-I/2

G-AM671P-48

G-AM675P-48

G-AM671P-48-Z2

G-AM3271P-MT-I/2

G-AM3271P-MT

230 V 50 Hz
480

G-AM3275P-MT

G-AM3271P-MT-Z2

G-AM3271P-235-I/2 ➏ G-AM3271P-235 ➏

G-AM3275P-235 ➏

G-AM3271P-235-Z2 ➏

480

G-AM3271P-48-I/2

G-AM3271P-48

G-AM3275P-48

G-AM3271P-48-Z2

120/208/240/277

G-AM771P-MT-I/2

G-AM771P-MT

G-AM775P-MT

G-AM771P-MT-Z2

G-AM771P-235-I/2 ➏

G-AM771P-235 ➏

G-AM775P-235 ➏

G-AM771P-235-Z2 ➏

G-AM771P-48-I/2

G-AM771P-48

G-AM775P-48

G-AM771P-48-Z2

120/208/240/277
320 W PSMH

400 W PSMH

230 V 50 Hz

230 V 50 Hz
480

Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

1157

Lighting

➊ Slip-fits 2” or 2-1/2” pipe-size tenons.
➋ Add suffix -E to catalog number if provision for quartz emergency option is desired. Furnished with socket installed and pre-wired.
➌ Quartz emergency option NOT available for Class I, Division 2 or Class I, Zone 2 fixtures. Classified duty floodlights have 1/2” N.P.T tapped hub for power entry.
Use 221 °F/105 °C supply wire.
➍ For Hot Restrike Option, add suffix –R.
➎ For 120 V 50 Hz change -225 to -125, or for 240 V 50 Hz change -225 to -245.
➏ For 120 V 50 Hz change -235 to -125.

Lighting: Enclosed and Gasketed — Floodlight

250 W PSMH

G-AM571P-48-I/2

120/208/240/277

Areamaster™ 250/400 Integrally Ballasted Floodlights V

70 W, 100 W, 150 W, 250 W, 400 W HPS; 175 W, 200 W, 250 W, 320 W, 400 W PSMH;
175 W, 250 W, 400 W MH
CEC V: For general, marine and hazardous
locations
Class I, Division 2, Groups A, B, C, D
Class I, Zone 2, Ex nR, Groups IIA, IIB, IIC
Class II, Division 1 and 2, Groups E, F, G
Class III

Line
Voltage

Lamp
High Pressure Sodium
120/277/347
70 W HPS ➍

100 W HPS ➍

150 W HPS ➍

250 W HPS

400 W HPS

Lighting

Lighting: Enclosed and Gasketed — Floodlight

400 W PSMH

For Class 1, Division 2
Classified Duty and
Marine Yoke Mount
Catalog Number ➋➌

For General Duty
Yoke Mount
Catalog Number ➋

Slip-Fit Mount
Catalog Number ➊➋

Class I, Zone 2
Yoke Mounting
Catalog Number ➌

G-AML271L-TT-I/2

—

—

G-AML271L-TT-Z2

220 V 50 Hz

G-AML271L-225-I/2 ➎

—

—

G-AML271L-225-Z2 ➎

600 ➐
120/277/347

G-AML271L-C7-I/2

—

—

G-AML271L-C7-Z2

G-AML371L-TT-I/2

—

—

G-AML371L-TT-Z2

220 V 50 Hz

G-AML371L-225-I/2 ➎

—

—

G-AML371L-225-Z2 ➎

600 ➐
120/277/347

G-AML371L-C7-I/2

—

—

G-AML371L-C7-Z2

G-AML471L-TT-I/2

—

—

G-AML471L-TT-Z2

220 V 50 Hz

G-AML471L-225-I/2 ➎

—

—

G-AML471L-225-Z2 ➎

600 ➐
120/277/347

G-AML471L-C7-I/2

—

—

G-AML471L-C7-Z2

G-AM671L-TT-I/2

G-AM671L-TT

G-AM675L-TT

G-AM671L-TT-Z2

230 V 50 Hz

G-AM671L-235-I/2 ➎

G-AM671L-235 ➎

G-AM675L-235 ➎

G-AM671L-235-Z2 ➏

600 ➐
120/277/347

G-AM671L-C7-I/2

G-AM671L-C7

G-AM675L-C7

G-AM671L-C7-Z2

G-AM771L-TT-I/2

G-AM771L-TT

G-AM775L-TT

G-AM771L-TT-Z2

230 V 50 Hz

G-AM771L-235-I/2 ➏

G-AM771L-235 ➏

G-AM775L-235 ➏

G-AM771L-235-Z2 ➏

G-AM771L-C7-I/2

G-AM771L-C7

G-AM775L-C7

G-AM771L-C7-Z2

G-AM571P-TT-I/2
G-AM2071P-TT-I/2
G-AM671P-TT-I/2

G-AM571P-TT
G-AM2071P-TT
G-AM671P-TT

G-AM575P-TT
G-AM2075P-TT
G-AM675P-TT

G-AM571P-TT-Z2
G-AM2071P-TT-Z2
G-AM671P-TT-Z2

G-AM671P-235-I/2 ➏
G-AM3271P-TT-I/2

G-AM671P-235 ➏
G-AM3271P-TT

G-AM675P-235 ➏
G-AM3275P-TT

G-AM671P-235-Z2 ➏
G-AM3271P-TT-Z2

600 ➐
Pulse Start Metal Halide
175 W PSMH
120/277/347
200 W PSMH
120/277/347
120/277/347
250 W PSMH
230 V 50 Hz
320 W PSMH

IP66
Marine type electric fixtures, outside type
(salt water)

120/277/347
230 V 50 Hz
120/277/347

G-AM3271P-235-I/2 ➏ G-AM3271P-235 ➏
G-AM771P-TT-I/2
G-AM771P-TT

G-AM3275P-235 ➏
G-AM775P-TT

G-AM3271P-235-Z2 ➏
G-AM771P-TT-Z2

230 V 50 Hz

G-AM771P-235-I/2 ➏

G-AM771P-235 ➏

G-AM775P-235 ➏

G-AM771P-235-Z2 ➏

120/277/347

G-AM571H-TT-I/2

G-AM571H-TT

G-AM575H-TT

G-AM571H-TT-Z2

220 V 50 Hz

Metal Halide
175 W MH

250 W MH

400 W MH

G-AM571H-225-I/2 ➎

G-AM571H-225 ➎

G-AM575H-225 ➎

G-AM571H-225-Z2 ➎

600 ➐

G-AM571H-C7-I/2

G-AM571H-C7

G-AM575H-C7

G-AM571H-C7-Z2

120/277/347

G-AM671H-TT-I/2

G-AM671H-TT

G-AM675H-TT

G-AM671H-TT-Z2

220 V 50 Hz

G-AM671H-225-I/2 ➎

G-AM671H-225 ➎

G-AM675H-225 ➎

G-AM671H-225-Z2 ➎

600 ➐

G-AM671H-C7-I/2

G-AM671H-C7

G-AM675H-C7

G-AM671H-C7-Z2

120/277/347

G-AM771H-TT-I/2

G-AM771H-TT

G-AM775H-TT

G-AM771H-TT-Z2

220 V 50 Hz

G-AM771H-225-I/2 ➎

G-AM771H-225 ➎

G-AM775H-225 ➎

G-AM771H-225-Z2 ➎

G-AM771H-C7-I/2

G-AM771H-C7

G-AM775H-C7

G-AM771H-C7-Z2

600 ➐

➊ Slip-fits 2” or 2-1/2” pipe-size tenons.
➋ Add suffix -E to catalog number if provision for quartz emergency option is desired. Furnished with socket installed and pre-wired.
➌ Quartz emergency option NOT available for Class I, Division 2 or Class I, Zone 2 fixtures. Classified duty floodlights have 1/2” N.P.T tapped hub for power entry.
Use 221 °F/105 °C supply wire.
➍ For Hot Restrike Option, add suffix –R.
➎ For 120 V 50 Hz change -225 to -125, or for 240 V 50 Hz change -225 to -245.
➏ For 120 V 50 Hz change -235 to -125.
➐ Supplied complete with CWI Isolated Secondary Ballast for 600 Vac. For 208, 240 or 480 V applications, change the -C7 suffix to -C2, -C3 or -C6 as required.
V CSA Certification only.

1158

Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

Areamaster™ 250/400 Integrally Ballasted Floodlights

70 W, 100 W, 150 W, 250 W, 400 W HPS; 175 W, 200 W, 250 W, 320 W, 400 W PSMH.
175 W, 250 W, 400 W MH V

Dimensions

Description

Catalog Numbers

Crossarm Mounting Bracket
Has 180° horizontal adjustment — degree marked. Facilitates mounting
floodlight to crossarm or other flat surface, or to G-AM-8-WB. Includes
floodlight yoke bolts. Malleable iron, zinc plated, chromate sealed,
architectural bronze polyester finish.

G-AM-8-CA

Used with G-AM-8-CA. Clamps to 1” to 2-1/2” pipe, vertical or horizontal,
or mounts on flat surfaces. Includes U-bolt and crossarm bracket bolts.
Malleable iron, zinc plated, chromate sealed, with architectural bronze polyster
finish.

G-AM-8-WB

Slip-fits 1-1/2” or 2” pipe size poletop tenons. Includes floodlight yoke bolts,
3 locking bolts, and cord grip.  Body is malleable iron-zinc plated, chromate
sealed, with cast aluminum cap.  Assembly has architectural bronze polyester
finish.

G-SF20

Pipe or Wall Mount Bracket

Poletop Slip-Fitter

Locking-Type Photocontrol Receptacle

For NEMA type photocontrol, with installation hardware and instructions.
Should not be mounted on Class I, Division 2/Class 1, Zone 2 units.

G-1PCR

UV stabilized polycarbonate, with installation hardware and instructions.

G-AM-6-VS

Easy to install with hardware supplied. Aluminum, with architectural bronze
POLYESTER finish.

G-AM-6-V

Vandal Shield

Replacement Lens

604249003

Lighting: Enclosed and Gasketed — Floodlight

Top Visor

Replacement Lens Frame Assembly
Complete with Lens

59607383002
Lighting

V CSA Certification only.
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

1159

Areamaster™ 250/400 Integrally Ballasted Floodlights

70 W, 100 W, 150 W, 250 W, 400 W HPS; 175 W, 200 W, 250 W, 320 W, 400 W PSMH.
175 W, 250 W, 400 W MH V

Lighting

Lighting: Enclosed and Gasketed — Floodlight

NEC: For general, marine and hazardous
locations
Class I, Division 2, Groups A, B, C, D
Class I, Zone 2, AEx nR, Groups IIA, IIB, IIC

Line
Type of
Frequency
Voltage
Ballast
70 Watt High Pressure Sodium
120
60
HX-HPF
208
60
HX-HPF
240
60
HX-HPF
277
60
HX-HPF
60
HX-HPF
347V
480
60
HX-HPF
120
50
HX-HPF
220
50
HX-HPF
240
50
HX-HPF
100 Watt High Pressure Sodium
120
60
HX-HPF
208
60
HX-HPF
240
60
HX-HPF
277
60
HX-HPF
60
HX-HPF
347V
480
60
HX-HPF
120
50
HX-HPF
220
50
HX-HPF
240
50
HX-HPF
150 Watt High Pressure Sodium
120
60
HX-HPF
208
60
HX-HPF
240
60
HX-HPF
277
60
HX-HPF
60
HX-HPF
347V
480
60
HX-HPF
120
50
HX-HPF
220
50
HX-HPF
240
50
HX-HPF
250 Watt High Pressure Sodium
120
60
CWA
208
60
CWA
240
60
CWA
277
60
CWA
60
CWA
347V
480
60
CWA
120
50
CWA
230
50
CWA
400 Watt High Pressure Sodium
120
60
CWA
208
60
CWA
240
60
CWA
277
60
CWA
60
CWA
347V
480
60
CWA
120
50
CWA
230
50
CWA
175 Watt Pulse Start Metal Halide
120
60
Super CWA
208
60
Super CWA
240
60
Super CWA
277
60
Super CWA
60
Super CWA
347V
480
60
Super CWA
200 Watt Pulse Start Metal Halide
120
60
Super CWA
208
60
Super CWA
240
60
Super CWA
277
60
Super CWA
60
Super CWA
347V
480
60
Super CWA

CEC V: For general, marine and hazardous
locations
Class I, Division 2, Groups A, B, C, D
Class I, Zone 2, Ex nR, Groups IIA, IIB, IIC
Class II, Division 1 and 2, Groups E, F, G
Class III

Starting
Amps

Operating
Amps

Total
Watts

0.90
0.50
0.44
0.35
0.30
0.21
1.08
0.59
0.54

0.82
0.48
0.41
0.36
0.30
0.21
0.81
0.49
0.45

94
94
94
94
93
94
97
97
97

1.30
0.76
0.66
0.60
0.45
0.33
0.90
0.50
0.45

1.15
0.67
0.60
0.52
0.39
0.31
1.20
0.65
0.60

130
130
130
130
130
135
130
130
130

2.00
1.15
1.00
0.85
0.52
0.50
1.50
0.85
0.75

1.70
0.95
0.85
0.72
0.56
0.47
1.60
0.90
0.80

188
188
188
188
188
189
188
188
188

2.00
1.20
1.00
0.85
0.60
0.40
1.85
0.95

2.50
1.50
1.30
1.10
0.93
0.65
2.75
1.44

295
295
295
295
295
295
300
300

3.30
1.80
1.60
1.40
1.00
0.80
3.70
1.85

3.80
2.20
1.90
1.70
1.32
1.00
4.00
2.00

465
465
465
465
464
465
465
465

0.90
0.50
0.35
0.30
0.25
0.25

1.78
1.08
0.89
0.76
0.65
0.50

199
199
199
199
208
213

2.10
1.15
1.10
0.75
0.25
0.35

2.00
1.25
1.00
0.85
0.70
0.50

235
235
235
235
232
237

NEC/CEC:
IP66
Marine type electric fixtures, outside type
(salt water)

Line
Type of
Starting
Frequency
Voltage
Ballast
Amps
250 Watt Pulse Start Metal Halide
120
60
Super CWA
1.90
208
60
Super CWA
1.10
240
60
Super CWA
0.96
277
60
Super CWA
0.85
60
Super CWA
0.62
347V
480
60
Super CWA
0.45
120
50
Super CWA
1.90
230
50
Super CWA
1.00
320 Watt Pulse Start Metal Halide
120
60
Super CWA
2.60
208
60
Super CWA
1.50
240
60
Super CWA
1.30
277
60
Super CWA
1.15
60
Super CWA
0.70
347V
480
60
Super CWA
0.60
120
50
Super CWA
2.28
230
50
Super CWA
1.14
400 Watt Pulse Start Metal Halide
120
60
Super CWA
3.50
208
60
Super CWA
2.00
240
60
Super CWA
1.25
277
60
Super CWA
1.50
60
Super CWA
1.10
347V
480
60
Super CWA
0.90
120
50
Super CWA
3.17
230
50
Super CWA
1.65
175 Watt Metal Halide V
120
60
CWA
1.30
208
60
CWA
0.75
240
60
CWA
0.65
277
60
CWA
0.55
347
60
CWA
0.50
480
60
CWA
0.35
120
50
CWA
1.70
220
50
CWA
0.80
250 Watt Metal Halide V
120
60
CWA
1.20
208
60
CWA
0.65
240
60
CWA
0.60
277
60
CWA
0.50
347
60
CWA
0.80
480
60
CWA
0.30
120
50
CWA
2.00
220
50
CWA
0.94
400 Watt Metal Halide V
120
60
CWA
3.25
208
60
CWA
1.90
240
60
CWA
1.65
277
60
CWA
1.40
347
60
CWA
1.20
480
60
CWA
0.85
120
50
CWA
2.70
220
50
CWA
1.50

Operating
Amps

Total
Watts

2.50
1.45
1.25
1.10
0.90
0.60
2.60
1.35

288
288
288
288
291
285
285
285

3.25
1.90
1.65
1.40
1.10
0.80
3.05
1.60

368
368
368
368
368
368
365
365

4.00
2.30
2.00
1.75
1.35
1.00
3.90
2.00

454
454
454
454
452
454
454
454

1.80
1.10
0.90
0.80
0.65
0.45
1.90
1.10

213
213
213
213
210
213
210
210

2.60
1.50
1.30
1.12
0.90
0.65
2.50
1.30

295
295
295
295
295
298
285
285

4.00
2.30
2.00
1.75
1.40
1.00
4.10
2.20

458
458
458
458
460
462
480
480

V CSA Certification only.

1160

Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

Areamaster™ 250/400 Integrally Ballasted Floodlights

70 W, 100 W, 150 W, 250 W, 400 W HPS; 175 W, 200 W, 250 W, 320 W, 400 W PSMH.
175 W, 250 W, 400 W MH V

Distance in terms of mounting height ◊

Typical Footcandle Values 

Ft. Cdles for Iso-Footcandle Lines
Mtg. Ht.
400W HPS
60’/18.3m
50’/15.2m
40’/12.2m
30’/9.1m
20’/6.1m

A

B

C

D

E

F

3.27
4.74
7.65
13.10
28.22

2.74
4.00
6.28
10.92
25.55

1.82
2.90
4.38
7.83
17.37

0.92
1.37
2.27
3.47
7.28

0.37
0.52
0.82
1.45
3.46

0.18
0.27
0.43
0.77
1.82

400W MH V
60’/18.3m
50’/15.2m
40’/12.2m
30’/9.1m
20’/6.1m

2.32
3.32
5.48
9.79
17.26

1.66
2.32
3.62
7.80
14.60

1.00
1.49
2.32
3.98
9.30

0.58
0.76
1.33
2.16
5.31

0.33
0.48
0.75
1.33
3.15

0.17
0.25
0.36
0.68
1.49

0.37
0.54
0.84
1.49
3.53

0.19
0.28
0.40
0.76
1.67

For 400W PSMH multiply FC values by 1.29; for 320W PSMH use 0.97.

400W PSMH
60’/18.3m
2.60
50’/15.2m
3.72
40’/12.2m
6.14
30’/9.1m
10.96
20’/6.1m
19.33

1.86
2.60
4.05
8.74
16.35

1.12
1.66
2.60
4.46
10.41

0.65
0.85
1.49
2.42
5.94

Ft. Cdles for Iso-Footcandle Lines

Distance in terms of mounting height ◊

Mtg. Ht.
70W HPS
10’/3.0m
20’/6.1m
30’/9.1m

G

H

I

J

K

L

10.00
2.50
1.00

5.00
1.00
0.50

2.50
0.50
0.25

1.00
0.25
0.10

0.50
0.10
0.05

0.25
0.05
0.02

For 100W HPS lamps, multiply FC values by 1.5. For 150W HPS lamps, multiply FC values by 2.5.

A

B

C

D

E

F

1.96
2.84
4.58
7.85
16.90

1.64
2.40
3.76
6.54
15.30

1.09
1.74
2.62
4.69
10.40

0.55
0.82
1.36
2.08
4.36

0.22
.031
0.49
0.87
2.07

0.11
0.16
0.26
0.46
1.09

250W MH V
60’/18.3m
50’/15.2m
40’/12.2m
30’/9.1m
20’/6.1m

1.40
2.00
3.30
5.90
10.40

1.00
1.40
2.18
4.70
8.80

0.60
0.90
1.40
2.40
5.60

0.35
0.46
0.80
1.30
3.20

0.20
0.29
0.45
0.80
1.90

0.10
0.15
0.22
0.41
0.90

For 175W MH lamps, multiply FC values by 0.68. For 175W PSMH Lamps 0.85; for 200W PSMH
use 1.03; for 250W PSMH use 1.22.

Distance in terms of mounting height ◊

250W PSMH
60’/18.3m
1.90
50’/15.2m
2.72
40’/12.2m
4.48
30’/9.1m
8.00
20’/6.1m
14.40

1.63
1.90
2.96
6.40
11.97

0.82
1.22
1.90
3.26
7.61

0.48
0.63
1.09
1.76
4.35

0.27
0.39
0.61
1.09
2.58

0.14
0.20
0.30
0.55
1.22

Lighting: Enclosed and Gasketed — Floodlight

Distance in terms of mounting height ◊

Ft. Cdles for Iso-Footcandle Lines
Mtg. Ht.
250W HPS
60’/18.3m
50’/15.2m
40’/12.2m
30’/9.1m
20’/6.1m

For 175W MH lamps, multiply FC values by 0.68. For 175W PSMH Lamps 0.85; for 200W PSMH
use 1.03; for 250W PSMH use 1.22.

Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

Lighting

 (i.e., ratio of distance to height. Example: @ 20’/6.1 m mounting height, 1 means 20’/6.1 m; 2 means 40’/12.2 m, etc.
 Photometric charts available on request.
V CSA Certification only.

1161

Areamaster™ 1000 Floodlights

Integrally Ballasted. 1000 W HPS; 1000 W, 1500 W MH
For general or hazardous locations.

NEC: For general, marine and hazardous
locations
Class I, Division 2, Groups A, B, C, D

CEC V: For general, marine and hazardous
locations
Class I, Division 2, Groups A, B, C, D
Class I, Zone 2, Ex nR, Groups IIA, IIB, IIC

Applications
•	 Powerful, efficient weatherproof floodlights for large areas 	
such as:
— Shopping malls
— Industrial complexes
— Ship loading areas
— Mining sites
— Parking lots
— Sports areas
•	 Suitable for wet locations.

Lighting

Lighting: Enclosed and Gasketed — Floodlight

Features
•	 Highly efficient, integrally ballasted floodlight. Has compact,
lightweight, yet rugged diecast aluminum construction.
Combines architecturally beautiful design with rugged
dependability, simple installation and maintenance.
•	 Easy to install and service.
•	 A wide range of ballasts and voltages are available for both
domestic and export applications.
•	 Integral ballast.
•	 One-piece housing.
•	 One-piece lens cover. Secured by four  1/4” Dia. captive
stainless steel slotted hex-head bolts.
•	 Thermal shock and impact resistant glass lens.
•	 Heavy duty, high temperature silicone rubber gasket, firmly
seated.
•	 Heavy duty mogul-base porcelain socket with heavy gauge
brass, nickel-plated, double lamp-grip screw shell and springloaded center contact.
•	 Compound parabolic, double segment, finished aluminum
reflector for optimum efficiency.
•	 Mounting choice:
(1) Yoke mount, zinc plated steel yoke with architectural bronze
polyester finish.
(2) Pole mount, built-in slip-fitter, for internal wiring, adjustable
laterally and vertically, slip fits 2” or 2-1/2” pipe, architectural
bronze polyester finish.
•	 Cool operating temperatures for Class I, Division 2 fixtures
translate into long luminaire life.

Yoke

Slip-Fit
Projected Area: 3.36 Sq. Ft.

Standard Materials
•	 Ballast housing and lens door: copperfree (4/10 of 1% max.)
aluminum
•	 Gasket: silicone rubber
•	 Socket: heavy duty porcelain with heavy gauge brass shell
•	 Reflector: finished aluminum
•	 Yoke mount: zinc plated steel
•	 Bolts: stainless steel

Standard Finishes
•	 Ballast housing, lens cover, yoke and pole mount: architectural
bronze polyester
•	 Socket: nickel-plated

Certifications and Compliances
•	 UL Standard: UL 1598, UL 844
•	 UL Listed: E10794

V CSA Certification only.

1162

Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

Areamaster™ 1000 Floodlights

Integrally Ballasted. 1000 W HPS; 1000 W, 1500 W MH
For general or hazardous locations.

NEC: For general, marine and hazardous
locations
Class I, Division 2, Groups A, B, C, D

Lamp
Watts ➍

Line
Voltage ➍

CEC V: For general, marine and hazardous
locations
Class I, Division 2, Groups A, B, C, D
Class I, Zone 2, Ex nR, Groups IIA, IIB, IIC

NEC/CEC
Class 1, Division 2
Classified Duty and
Marine Yoke Mount
Catalog Number ➌

General Duty

CEC
Class I, Zone 2, Ex nR
Classified Duty and
Marine Yoke Mount
Catalog Number ➌

NEC/CEC
Yoke Mount
Catalog Number ➋

NEC/CEC
Slip-Fit Mount
Catalog Number ➊➋

G-AM861L-MT-I/2

G-AM861L-MT

G-AM865L-MT

G-AM861L-MT-Z V

G-AM861L-TT-I/2 V

G-AM861L-TT V

G-AM865L-TT V

G-AM861L-TT-Z V

High Pressure Sodium
1000

120/208/240/277

1000

120/277/347

1000

480

G-AM861L-48-I/2

G-AM861L-48

G-AM865L-48

G-AM861L-48-Z V

1000

120/208/240/277

G-AM861H-MT-I/2

G-AM861H-MT

G-AM865H-MT

G-AM861H-MT-Z V

1000

120/277/347

G-AM861H-TT-I/2 V

G-AM861H-TT V

G-AM865H-TT V

G-AM861H-TT-Z V

1000

480

G-AM861H-48-I/2

G-AM861H-48

G-AM865H-48

G-AM861H-48-Z V

1500

120/208/240/277

—

G-AM961H-MT

G-AM965H-MT

—

1500

480

—

G-AM961H-48

G-AM965H-48

—

Metal Halide

Dimensions

Lighting: Enclosed and Gasketed — Floodlight

Slip-Fit Mount

Yoke Mount

Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

Lighting

➊ Slip-fits 2” or 2-1/2” pipe-size tenons.
➋ Add suffix -E to catalog number if provision for bayonet type quartz emergency option is desired. Furnished with socket installed and pre-wired. Quartz
emergency option NOT available for Class I, Division 2 fixtures.
➌ Classified duty floodlights have 3/4” N.P.T. tapped hub for power entry.
➍ Additional ballast types and voltages are available. Contact your local sales representative.
V CSA Certification only.

1163

Areamaster™ 1000 Floodlight Mounting Fittings and Accessories
Integrally Ballasted. 1000 W HPS; 1000 W, 1500 W MH
For general or hazardous locations.

Dimensions

Description

Catalog Numbers

Crossarm Mounting Bracket
Has 180° horizontal adjustment — degree marked. Facilitates mounting
floodlight to crossarm or other flat surface, or to G-AM-8-WB. Includes
floodlight yoke bolts. Malleable iron, zinc plated, chromate sealed,
architectural bronze polyester finish.

G-AM-8-CA

Used with G-AM-8-CA. Clamps to 1” to 2-1/2” pipe, vertical or horizontal,
or mounts on flat surfaces. Includes U-bolt and crossarm bracket bolts.
Malleable iron, zinc plated, chromate sealed, with architectural bronze polyster
finish.

G-AM-8-WB

Slip-fits 2” or 2-1/2” poletop tenons. Includes floodlight yoke bolts, 3 locking
bolts, and cord grip. Malleable iron, zinc plated, chromate sealed, with
architectural bronze POLYESTER finish.

G-AM-8-SF

Pipe or Wall Mount Bracket

Poletop Slip-Fitter

Locking-Type Photocontrol Receptacle

For NEMA type photocontrol, with installation hardware and instructions.
Should not be mounted on Class I, Division 2 units.

G-1PCR

UV stabilized polycarbonate, with installation hardware and instructions.

G-AM-8-NVS

Easy to install with hardware supplied. Aluminum, with architectural bronze
POLYESTER finish.

G-AM-6-NV

Lighting: Enclosed and Gasketed — Floodlight

Vandal Shield

Top Visor

Replacement Lens

59604249004

Replacement Lens Frame Assembly
59617539001

Lighting

Complete with Lens

1164

Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

Areamaster™ 1000 Floodlight Photometric Data
Integrally Ballasted. 1000 W HPS; 1000 W, 1500 W MH
For general or hazardous locations.

Photometric Data †

Typical Footcandle Values †

HPS
134°
131°
77,440
55.3%
40,251
38,396
80,846
57.7%

Horiz. Spread
Vert. Spread
Beam Lumens
Beam Effic.
Max. CP
Avg. Max. CP
Total Lumens
Total Effic.

MH
133°
124°
62,112
56.5%
45,909
38,490
66,008
60.0%

Electrical Specifications
Lamp
Line
Type of
Starting
Type
Voltage
Ballast
Amps
1000 Watt High Pressure Sodium
HPS
120
C.W.A.
6.35
HPS
208
C.W.A.
3.80
HPS
240
C.W.A.
3.20
HPS
277
C.W.A.
2.75
HPS
347
C.W.A.
2.20
HPS
480
C.W.A.
1.80
1000 Watt Metal Halide
MH
120
C.W.A.
8.00
MH
208
C.W.A.
4.60
MH
240
C.W.A.
4.00
MH
277
C.W.A.
3.50
MH
347
C.W.A.
2.50
MH
480
C.W.A.
2.00
1500 Watt Metal Halide
MH
120
C.W.A.
13.50
MH
208
C.W.A.
7.70

Mtg. Ht.
Ft/M

A

Footcandle Values for Iso Footcandle Lines
B
C
D
E

F

1000W HPS Clear, 140,000 Lumens, Cat. No. G-AM861L-MT
60/18.3
8.0
3.0
1.0
0.5
0.20
0.10
50/15.2
11.5
4.6
1.5
0.72
0.27
0.15
40/12.2
17.3
6.8
2.4
1.0
0.45
0.21
30/9.1
31.5
12
4.1
1.9
0.80
0.30
1000W MH Clear, 110,000 Lumens, Cat. No. G-AM861H-MT
60/18.3
6.0
3
1.0
0.5
0.20
0.10
50/15.2
8.2
4.2
1.4
0.8
0.28
0.15
40/12.2
12.6
7.9
2.3
1.2
0.42
0.19
30/9.1
23.0
11.6
4.0
2.1
0.70
0.25

240

C.W.A.

6.70

Total
Watts

9.50
5.50
4.80
4.20
3.30
2.45

1100
1100
1100
1100
1100
1100

9.20
5.30
4.60
4.00
3.20
2.30

1080
1080
1080
1080
1080
1080

14.00
8.00

1610
1610

7.00

1610

MH

277

C.W.A.

5.90

6.00

1610

MH

480

C.W.A.

3.30

3.50

1610

T Numbers and Temperature Ratings of “Classified Duty”
Areamaster 1000
Fixture
Wattage

Fixture Type

T Ratings
Ambient
°C
Temp. ˚°F/°C

T Rating Temperature
Range °F/°C

1000

Class I	
Div 2

325

77/25

574-617 / 301-325

1000 V

Ex nR IIC

T3

77/25

277-392 / 136-200

Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

Lighting

† Photometric charts available on request.
◊ i.e., ratio of distance to height. Example: @20’/6.1 m mounting height, 1 means 20’/6.1 m; 2 means 40’/12.2 m, etc.
V CSA Certification only.

Lighting: Enclosed and Gasketed — Floodlight

MH

Operating
Amps

1165

PN Series Floodlights – Zone 2, 21 and 22

Metal Halide, Sodium and Mercury

Listed for si­mul­ta­ne­ous ex­po­sure to gas, com­bust­i­ble dusts and flam­ma­ble gas­es or va­pors.
Zone 2, 21 and 22
II 2 D II 3 GD
ATEX / IECEx
IP66 - IK07/08

Applications
•	 Powerful, efficient floodlights for large areas such as industrial
complexes and ship loading areas.
•	 Rated for use in hazardous areas.

Features
•	 Highly efficient, integrally ballasted floodlight. Has compact,
lightweight, yet rugged die cast aluminum construction.
•	 Simple installation and maintenance.
•	 Integral ballast; 230/240 V, 50 Hz.
•	 One-piece lens cover.
•	 Heavy duty, high temperature silicone rubber gasket, firmly
seated.
•	 Socket: E40 (E27 for 70 W HPS version).
•	 Reflectors: double segment compound parabolic with Alzack®
finish for maximum efficiency.
•	 Mounting: yoke mount.

Standard Materials
•	 Ballast housing and lens door: copperfree (4/10 of 1% max.)
aluminum
•	 Gasket: silicone rubber
•	 Socket: heavy duty porcelain with heavy gauge brass shell
•	 Reflector: finished aluminum
•	 Yoke mount: zinc plated steel
•	 Bolts: stainless steel

Standard Finishes
•	 Ballast housing, lens cover, yoke and pole mount: architectural
bronze polyester
•	 Socket: nickel-plated
•	 Size M — Certification Type PJn
— Gas: Zone 2
	  Conforming to ATEX 94/9/CE: CE
3G
	  ATEX/IEC Protection: Ex nR II
	  T Rating: T2 to T4
	  Ambient Temperature: 104 °F to 131 °F/40 °C to 55 °C
— Dust: Zone 22
II 3 D
	  Conforming to ATEX 94/9/CE: CE
	  ATEX/IEC Protection: Ex tD A22
	  Surface Temperature: T243 °F/T117 °C to 442 °F/T228 °C
— Gas, Zone 2 and Dust, Zone 22
	  Ambient Temperature: 104 °F to 131 °F / 40 °C to 55 °C
	  ATEX Certificate: LCIE 08 ATEX 6035X
	  IEC Certificate: IECEx LCI 04.0015
	  Other Certifications: GOST
	  Impact Resistance (shock): IK07
— Dust: Zone 21
I2D
	  Conforming to ATEX 94/9/CE: CE
	  ATEX/IEC Protection: Ex tD A21
	  Surface Temperature: T149 °F to T277 °F/T65 °C to
  T136  °C
	  Ambient Temperature: -4 °F to 104 °F/-20 °C to 40 °C
	  ATEX Certificate: LCIE 02 ATEX 6246X
	  Impact Resistance (shock): IK07 with glass diffuser, IK08
  with polycarbonate diffuser
— CE Declaration of Conformity: 50251
— Index of Protection (solid and liquid): IP66

Lighting

Lighting: Enclosed and Gasketed — Floodlight

Certifications and Compliances

•	 Size G — Certification Type PJn
— Gas: Zone 2
	  Conforming to ATEX 94/9/CE: CE
3G
	  ATEX/IEC Protection: Ex nR II
	  T Rating: T3
— Dust: Zone 22
	  Conforming to ATEX 94/9/CE: CE
II 3 D
	  ATEX/IEC Protection: Ex tD A22
	  Surface Temperature: T369 °F to T378 °F/T187 °C
  to T192 °C
— Gas, Zone 2 and Dust, Zone 22
	  Ambient Temperature: 104 °F to 131 °F/40 °C to 55 °C
	  CE Declaration of Conformity: 50215
	  ATEX Certificate: LCIE 08 ATEX 6035X
	  IEC Certificate: IECEx LCI 04.0015
	  Other Certifications: GOST
	  Impact Resistance (shock): IK07
— Dust: Zone 21
	  Conforming to ATEX 94/9/CE: CE 008
II 2 D
	  ATEX/IEC Protection: Ex tD A21
	  Surface Temperature: T250°F to T360°F / T121°C
  to T182°C
	  Ambient Temperature: -4°F to 104°F / -20°C to 40°C
	  CE Declaration of Conformity: 50274
	  ATEX Certificate: LCIE 02 ATEX 6246X
	  Impact Resistance (shock): IK07 with glass diffuser, IK08
  with polycarbonate diffuser
— Index of Protection (solid and liquid): IP66
•	 Ex Standards: EN/IEC 60079-0, 60079-15, 61241-0, 61241-1
•	 Product Standards: EN/IEC 60598-1
•	 EMC Standards: EN/IEC 55015, 61547
•	 Other Standards: EN/IEC 60529 (IP)

1166

Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

PN Series Floodlights – Zone 2, 21 and 22

Metal Halide, Sodium and Mercury

Listed for si­mul­ta­ne­ous ex­po­sure to gas, com­bust­i­ble dusts and flam­ma­ble gas­es or va­pors.
Zone 2, 21 and 22
II 2 D II 3 GD
ATEX / IECEx
IP66 - IK07/08

Order using catalog numbering guide below or select catalog number from tables on following pages.
Catalog Numbering Guide For PN Series Luminaires
PN

P

Series:
PN - PN Series
Zone 2, 21 & 22
ATEX / IEC Certified	

Body Size:
P - Small
M - Medium
L - Large

1

H

Mounting:
1 - Yoke
5 - Pole Slip-fit

70
Wattage:
70 - 70 W
15 - 150 W
25 - 250 W
40 - 400 W ①
99 - 1000 W ①

Lamp Type:
H - Metal Halide
L - Sodium
M - Mercury

A

G

MT

Diffuser:
G - Glass
P - Polycarbonate ②

Entry Size:
A - M20

F
Options:
S - Stainless Steel
Housing

Options:
XA - 220 Vac 50 Hz
(Magnetic Ballast)
XJ - 230/240 Vac 50 Hz
(Magnetic Ballast)

Lighting: Enclosed and Gasketed — Floodlight

Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

Lighting

① 400 W Zones 21-22 and 1000 W Zones 2-22 only with large body (suffix -G).
② Zone 2-22 doesn’t exist with polycarbonate diffuser.

1167

PN Series Floodlight T Ratings – Zone 2, 21 and 22

Metal Halide, Sodium and Mercury

Listed for si­mul­ta­ne­ous ex­po­sure to gas, com­bust­i­ble dusts and flam­ma­ble gas­es or va­pors.
Zone 2, 21 and 22
II 2 D II 3 GD
ATEX / IECEx
IP66 - IK07/08

Zone 21 (Dust)
Dust Surface Temperatures for Ta = 104 °F/40 °C





Operating Position

Body Size: M

Body Size: L

Lamp and Power
70 W Sodium
150 W Sodium
250 W Sodium
250 W Metal Halide
250 W Mercury
400 W Sodium
1000 W Sodium
1000 W Metal Halide

Glass Diffuser
167 °F/75 °C
213.8 °F/101 °C
260.6 °F/127 °C
253.4 °F/123 °C
276.8 °F/136 °C
25.8 °F/126 °C
350.6 °F/177 °C
359.6 °F/182 °C

Polycarbonate Diffuser
149 °F/65 °C
195.8 °F/91 °C
242.6 °F/117 °C
235.4 °F/113 °C
267.8 °F/131 °C
249.8 °F/121 °C
–
–

Time Before Opening
in Inches/Millimeters
1.97/50
0.99/25
0.59/15
0.59/15
0.59/15
1.18/30
1.18/30
1.18/30

Lamp and Power
70 W Sodium
150 W Sodium
150 W Metal Halide
250 W Sodium
250 W Metal Halide
250 W Mercury
400 W Sodium
400 W Metal Halide
400 W Mercury
1000 W Sodium
1000 W Metal Halide

T Rating for Ta = 104 °F/40 °C
T4
T4
T4
T3
T3
T3
T3
T2
T2
T3
T3

T Rating for Ta = 122 °F/50 °C
T4
T4
T4
T3
T3
T3
T3 (Cable T ° = 188.6 °F/87 °C)
T2 (Cable T ° = 183.2 °F/84 °C)
T2 (Cable T ° = 183.2 °F/84 °C)
T3
T3

T Rating for Ta = 131 °F/55 °C
T4
T4
T4
T3 (Cable T ° = 179.6 °F/82 °C)
T3
T3 (Cable T ° = 177.8 °F/81 °C)
T2 (Cable T ° = 197.6 °F/92 °C)
T2 (Cable T ° = 192.2 °F/89 °C)
T2 (Cable T ° = 192.2 °F/89 °C)
–
–

Lamp and Power
70 W Sodium
150 W Sodium
150 W Lodure
250 W Sodium
250 W Lodure
250 W Mercury
400 W Sodium
400 W Lodure
400 W Mercury

T Rating for Ta = 104 °F/40 °C
242.6 °F/117 °C
2.66 °F/130 °C
262.4 °F/128 °C
320 °F/160 °C
47 °F/175 °C
357.8 °F/181 °C
388.4 °F/198 °C
442.4 °F/228 °C
440.6 °F/227 °C
368.6 °F/187 °C 	
(for Ta = 122 °F/50 °C)
377.6 °F/192 °C 	
(for Ta = 122 °F/50 °C)

T Rating for Ta = 122 °F/50 °C
–
–
–
–
–
–
T3 (Cable T ° = 188.6 °F/87 °C)
T2 (Cable T ° = 183.2 °F/84 °C)
T2 (Cable T ° = 183.2 °F/84 °C)

T Rating for Ta = 131 °F/55 °C
–
–
–
T3 (Cable T ° = 179.6 °F/82 °C)
–
T3 (Cable T ° = 177.8 °F/81 °C)
T2 (Cable T ° = 197.6 °F/92 °C)
T2 (Cable T ° = 192.2 °F/89 °C)
T2 (Cable T ° = 192.2 °F/89 °C)

Cable T ° = 194 °F/90 °C

–

Cable T ° = 194 °F/90 °C

–

Zone 2 (Gas)

Body Size: M

Lighting: Enclosed and Gasketed — Floodlight

Body Size: L

Zone 22 (Dust)

Body Size: M

1000 W Sodium
Body Size: L

Lighting

1000 W Lodure

1168

Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

PN Series Floodlights – Zone 2, 21 and 22

Metal Halide, Sodium and Mercury

Listed for si­mul­ta­ne­ous ex­po­sure to com­bust­i­ble dusts and flam­ma­ble gas­es or va­pors.
Zone 2, 21 and 22
II 2 D II 3 GD
ATEX / IECEx
IP66 - IK07/08

Type

Weight (lbs/kg)

Volume (in3/dm3)

Permissible lamps
(not supplied)

Body Size

Catalog Number

Standard with Lamp Glass Sealed on Frame
70 W HP Sodium

26.7/12.1

3814/62.5

Ovoid/Tubular

Medium

PNM1L70AGXJ

150 W HP Sodium

28.4/12.9

3814/62.5

Ovoid/Tubular

Medium

PNM1L15AGXJ

250 W HP Sodium

31.5/14.3

3814/62.5

Ovoid/Tubular

Medium

PNM1L25AGXJ

400 W HP Sodium

35.3/16.0

3814/62.5

Ovoid/Tubular

Medium

PNM1L40AGXJ

400 W HP Sodium

–

–

Ovoid/Tubular

Large

PNL1L40AGXJ

150 W Metal Halide

28.4/12.9

3814/62.5

Ovoid/Tubular

Medium

PNM1H15AGXJ

250 W Metal Halide

31.5/14.3

3814/62.5

Ovoid/Tubular

Medium

PNM1H25AGXJ

400 W Metal Halide

35.3/16.0

3814/62.5

Tubular

Medium

PNM1H40AGXJ

400 W Metal Halide

–

–

Ovoid/Tubular

Large

PNL1H40AGXJ

250 W Mercury Vapor

28.4/12.9

3814/62.5

Ovoid

Medium

PNM1M25AGXJ

400 W Mercury Vapor

30.4/13.8

3814/62.5

Ovoid/Tubular

Medium

PNM1M40AGXJ

With External Polycarbonate Weatherproof Protection
70 W HP Sodium

29.1/13.2

3814/62.5

Ovoid/Tubular

Medium

PNM1L70APXJ

150 W HP Sodium

30.9/14.0

3814/62.5

Ovoid/Tubular

Medium

PNM1L15APXJ

250 W HP Sodium

34.0/15.4

3814/62.5

Ovoid/Tubular

Medium

PNM1L25APXJ

400 W HP Sodium

–

–

Ovoid/Tubular

Large

PNL1L40APXJ

150 W Metal Halide

30.9/14.0

3814/62.5

Ovoid/Tubular

Medium

PNM1H15APXJ

250 W Metal Halide

34.0/15.4

3814/62.5

Ovoid/Tubular

Medium

PNM1H25APXJ

–

–

Ovoid/Tubular

Large

PNL1H40APXJ

30.9/14.0

3814/62.5

Ovoid

Medium

PNM1M25APXJ

400 W Metal Halide
250 W Mercury Vapor

Description

Catalog Number

Fall Prevention Kit
(3.94"/1.2 m stainless steel chain) for M20 cable entry

FESCM20

Slipfitter Adapter — fits medium body

GSF20

Slipfitter Adapter — fits large body

GAM8SF

Lighting: Enclosed and Gasketed — Floodlight

Accessories

Lighting

Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

1169

PN Series Floodlight Dimensions and Photometric Data – Zone 2, 21 and 22

Metal Halide, Sodium and Mercury

Listed for si­mul­ta­ne­ous ex­po­sure to com­bust­i­ble dusts and flam­ma­ble gas­es or va­pors.

Dimensions
Size M

Size L
7.76”/197 mm
7.36”/
197 mm

22.17”/563.0 mm

5.55”/
141.0 mm
3.50”/
89.0 mm
2.78”/
70.5 mm

2.01”/
51.0 mm

(3) Mounting Holes
0.55”/14.0 mm

16.14”/410.0 mm

2.01”/
51.0 mm
5.55”/
141.0 mm
(3) Mounting Holes
0.54”/13.8 mm
3.50”/
89.0 mm

5.12”/
130.0 mm
5.12”/
130.0 mm

2.17”/
55.0 mm

3.50”/
89 mm

11.22”/
285.0 mm

13.50”/
343.0 mm

19.68”/500.0 mm
22.17”/563.0 mm

16.92”/460.0 mm

3.62”/
92.0 mm

3.62”/
92.0 mm

Photometric Data

Lamps: 70 W High Pressure Sodium
Polar curves for a 1000 lm flux, according to NF C 71-120
Luminaire symbol according to NF C 71-121
Candelas
(0-180)

(90-270)

0

487

487

5

439

461

10

416

387

15

372

324

20

208

290

25

129

294

30

116

319

35

111

318

40

101

289

45

86

193

50

70

150

55

84

141

60

62

132

65

22

88

70

9

15

Total Luminaire Efficiency = 74.6%
Degrees

Longitudinal
Transverse

Lighting

Lighting: Enclosed and Gasketed — Floodlight

Degrees

1170

Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

Corroflood™ 250/400 Stainless Steel Floodlights
Integral Ballast. 250 W, 400 W HPS or PSMH. Mogul Base

For Marine; Class I, Division 2 Hazardous Locations; Class I, Zone 2; and Corrosive Environments.
Class I, Division 2, Groups A, B, C, D
NEMA 4X
Suitable for Marine, Outdoor Salt Water
Location

Applications
•	 Powerful, efficient weatherproof lighting for medium and large
areas such as chemical plants, refineries, shipboard and marine
industrial process areas where severely corrosive agents are
present.

Features
•	 Compact in size, rugged and dependable.
•	 Easy to install and service.
•	 A wide range of ballasts and voltages are available for both
domestic and export applications.
•	 Integral ballast.
•	 Completely assembled fixture saves installation time and cost.
•	 Easily removable ballast tray.
•	 Hinged door.
•	 Seamless welded construction.
•	 Can be mounted in any position ranging from lens down to
horizontal, lens up.
•	 Stainless steel latches to allow relamping without tools.

Standard Materials
•	 Fixture body and trunnion arm: 316 stainless steel
•	 16 gauge 316 stainless steel
•	 Lens: thermal-shock-resistant and tempered impact-resistant
glass
•	 Gasket: heavy-duty, high-temperature silicone rubber, firmly
seated
•	 Socket: heavy-duty, mogul base porcelain with heavy gauge
brass, nickel-plated, double lamp-grip screw shell and springloaded center contact
•	 Reflector: compound parabolic, double segment, finished
aluminum for optimum efficiency

Certifications and Compliances
•	 UL Standard: UL 1598, UL 1598A, UL 844
•	 UL Listed: E10794

Line Voltage

T Rating

For Class I, Division 2
Classified Duty and Marine
Yoke Mount Catalog Number ➋

High Pressure Sodium
400 W HPS

120/208/240/277

350

SSF771L-MT-I/2

400 W HPS

120/277/347

350

400 W HPS
250 W HPS

480
120/208/240/277

350
350

SSF771L-TT-I/2 V
SSF771L-48-I/2
SSF671L-MT-I/2

250 W HPS

120/277/347

350

480

350

SSF671L-TT-I/2 V
SSF671L-48-I/2

250 W HPS
Pulse Start Metal Halide
400 W PSMH

120/208/240/277

350

SSF771P-MT-I/2

400 W PSMH

120/277/347

350

400 W PSMH
250 W PSMH

480
120/208/240/277

350
350

SSF771P-TT-I/2 V
SSF771P-48-I/2
SSF671P-MT-I/2

250 W PSMH

120/277/347

350

250 W PSMH

480

350

SSF671P-TT-I/2 V
SSF671P-48-I/2

Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

1171

Lighting

Floodlights have 3/4” NPT tapped hub for power entry.
➊ Quartz emergency option NOT available for Class I, Division 2 fixtures. Contact your local sales representative for emergency quartz for non-classified areas.
V CSA Certification only.

Lighting: Enclosed and Gasketed — Floodlight

Lamp Type

Corroflood™ 250/400 Stainless Steel Floodlights
Integral Ballast. 250 W, 400 W HPS or PSMH. Mogul Base

For Marine; Class I, Division 2 Hazardous Locations; Class I, Zone 2; and Corrosive Environments.

Mounting Fittings and Accessories
Description

Catalog Number

Crossarm Mounting Bracket — Has 180° horizontal adjustment—degreemarked. Facilitates mounting floodlight to crossarm or other flat surface, or to
G-AM-8-WB. 	
Includes floodlight yoke bolts. Malleable iron, zinc plated, chromate sealed,
architectural bronze polyester finish.
Pipe or Wall Mount Bracket — Used with G-AM-8-CA. Clamps to 1” to
2-1/2” pipe, vertical or horizontal, or mounts on flat surfaces. Includes U-bolt
and crossarm bracket bolts. Malleable iron, zinc plated, chromate sealed, with
architectural bronze POLYESTER finish.
Poletop Slip-Fitter — 1-1/2” or 2” pipe size poletop tenons. Includes floodlight
yoke bolt, 3 locking bolts, and cord grip. Body is malleable iron—zinc plated,
chromate sealed, with cast aluminum cap. Assembly has architectural bronze
polyester finish.

G-AM-8-CA

G-AM-8-WB

G-SF20

Poletop Slip-Fitter — Slip-Fits 2” or 2-1/2” poletop tenons. Includes floodlight
yoke bolts, 3 locking bolts and cord grip.  Malleable iron, zinc plated, chromate
sealed, with architectural bronze polyester finish.

G-AM-8-SF

Dimensions
7.00”/
177.8 mm

Lighting: Enclosed and Gasketed — Floodlight

23.00”/584.2 mm

18.50”/469.9 mm

17.25”/438.15 mm

0.38”/9.1 mm
Dia. (2) Outer Holes

0.56”/14.3 mm
Dia. Center Hole

18.50”/469.9 mm

1.75”/
44.45 mm

3.50”/
88.9 mm

Trunnion Mount
3.50”/88.9 mm

6.00”/152.4 mm

4.50”/
114.3 mm

Lighting

4.00”/101.6 mm

Crossarm Mounting Bracket

1172

Pipe or Wall Mount Bracket

Poletop Slip-Fitter

Poletop Slip-Fitter

Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

Corroflood™ 250/400 Stainless Steel Floodlight Photometric Data
Integral Ballast. 250 W, 400 W HPS or PSMH. Mogul Base

For Marine; Class I, Division 2 Hazardous Locations; Class I, Zone 2; and Corrosive Environments.

Electrical Specifications — All ballasts are CWA type

Typical Footcandle Values †

Line Voltage
Starting Amps
400 W High Pressure Sodium
120
3.30
208
1.80
240
1.60
277
1.40
347
1.00
480
0.80
400 W Pulse Start Metal Halide
120
3.50
208
2.00
240
1.25
277
1.50
347
1.10
480
0.90
250 W High Pressure Sodium
120
2.00
208
1.20
240
1.00
277
0.85
347
0.60
480
0.40
250 W Pulse Start Metal Halide
120
1.90
208
1.10
240
0.96

60/18.3
50/15.2
40/12.2
30/9.1
20/6.1
60/18.3
50/15.2
40/12.2
30/9.1
20/6.1

Total Watts

3.80
2.20
1.90
1.70
1.32
1.00

465
465
465
465
464
465

4.00
2.30
2.00
1.75
1.35
1.00

454
454
454
454
452
454

2.50
1.50
1.30
1.10
0.93
0.65

295
295
295
295
295
295

2.50
1.45
1.25

288
288
288

277

0.85

1.10

288

347

0.62

0.90

291

480

0.45

0.60

285

Footcandles for Iso-Footcandle Lines
A
B
400 W HPS
3.27
2.74
4.74
4.00
7.65
6.28
13.10
10.92
28.22
25.55
400 W PSMH
2.60
1.86
3.72
2.60
6.14
4.05
10.96
8.74
19.33
16.35

C

D

E

F

1.82
2.90
4.38
7.83
17.37

0.92
1.37
2.27
3.47
7.28

0.37
0.52
0.82
1.45
3.46

0.18
0.27
0.43
0.77
1.82

1.12
1.66
2.60
4.46
10.41

0.65
0.85
1.49
2.42
5.94

0.37
0.54
0.84
1.49
3.53

0.19
0.28
0.40
0.76
1.67

A
B
250 W HPS
1.96
1.64
2.84
2.40
4.58
3.76
7.85
6.54
16.90
15.30
250 W PSMH
1.90
1.36
2.72
1.90
4.48
2.96
8.00
6.40
14.40
11.97

C

D

E

F

1.09
1.74
2.62
4.69
10.40

0.55
0.82
1.36
2.08
4.36

0.22
0.31
0.49
0.87
2.07

0.11
0.16
0.26
0.46
1.09

0.82
1.22
1.90
3.26
7.61

0.48
0.63
1.09
1.76
4.35

0.27
0.39
0.61
1.09
2.58

0.14
0.20
0.30
0.55
1.22

Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

Lighting

† Photometric charts available on request.
◊ i.e., ratio of distance to height. Example: @ 20’/6.1 m mounting height, 1 means 20’/6.1 m; 2 means 40’/12.2 m, etc.

Lighting: Enclosed and Gasketed — Floodlight

Mtg. Ht.
Ft/M

Operating Amps

1173

Wallmaster I/2 for Hazardous and Wet Locations — Class I, Division 2/Zone 2 V
cCSAus Certification Only. Enclosed and Gasketed. Integrally Ballasted. 70 W, 100 W, 150 W HPS
Class I, Division 2, Groups A, B, C, D
Class I, Zone 2, Groups IIA, IIB, IIC

Applications
•	 Wall mounted luminaire suitable for outdoor applications.
•	 Areas where flammable gases are present under conditions
defines by NEC Class I, Division 2.

Features
•	 Attractive yet rugged design.
•	 Side hinged door allows unobstructed access to lamp and
wiring components.
•	 Built in stop limits door opening to 90° and protects the lens
from breakage.
•	 Latch mechanism: unique heavy-duty stainless steel latch
secures the cover assembly while allowing the luminaire to be
relamped without the use of tools.
•	 Prismatic tempered glass lens is thermal-shock- and impactresistant giving a soft diffused light.
•	 Installation is fast and easy.
•	 Luminaire is furnished with two plugged 1/2” conduit entries. A
1/2” knockout allows rear entry.
•	 Mogul base socket is heavy-duty porcelain with heavy gauge
brass nickel plated double lamp grip screw shell and spring
loaded center contacts.
•	 Aluminum reflector is designed for maximum efficiency.
•	 Standard finish is architectural 	
bronze tone baked epoxy.

Certifications and Compliances
•	
•	
•	
•	

UL Standard: UL 1598, UL 844
CSAus Certified: 025428
CSA Standard: C22.2 No. 250, C22.2 No. 137
CSA Certified: 025428

Order using catalog numbering guide below.
Catalog Numbering Guide For Wallmaster I/2 Luminaires

Lighting: Enclosed and Gasketed — Floodlight

Series:
GWM - Wallmaster

Lighting

GWN

V CSA Certification only.

70

L
Lamp Type:
L - High Pressure  Sodium
F - Fluorescent

Wattage:
70 - 70 W HPS	
10 - 100 W HPS
15 - 150 W HPS
36 - Two 18 W PL-T
52 - Two 26 W PL-T
64 - Two 32 W PL-T

1174

MT

H

R

Ratings:
H - Hazardous Location

Voltage:
48 - 480
MT - 120/208/240/277
BU - 120-277, 50/60 Hz  (Fluorescent
Only)
TT - 120/277/347

Options:
E – Quartz Auxiliary Light (NonHazardous HID only)
G – Wire Guard
Q – Hazardous Photocontrol 120
to 277 Vac (Class I, Div. 2)
R – HRE (Hot Restrike for HID
only)
S – PE (Safety Starter for HID
only)
T – Tamper proof Latch
V – Polycarbonate Vandal Shield

Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

Wallmaster I/2 for Hazardous and Wet Locations — Class I, Division 2/Zone 2 V
cCSAus Certification Only. Enclosed and Gasketed. Integrally Ballasted. 70 W, 100 W, 150 W HPS
Class I, Division 2, Groups A, B, C, D
Class I, Zone 2, Groups IIA, IIB, IIC

“T” Numbers for Wallmaster I/2 Fixtures
Lamp
Watts

Lamp
Type

Supply
Wire °F/°C

Maximum Ambient
Temperature °F/°C

Class I, Division 2
Class I, Zone 2

70

HPS

257/125

104/40

T2D

100

HPS

257/125

77/25

T2C

150

HPS

257/125

77/25

T2A

36

Fluorescent

257/125

104/40
131/55

T3

52

Fluorescent

257/125

104/40
131/55

T3

64

Fluorescent

257/125

104/40
131/55

T3

“T” Numbers Represent the Maximum Lamp Temperature for Class I, Division 2 Locations
“T”
Number

T1

350

325

T2

T2A

T2B

T2C

T2D

T3

T3A

T3B

T3C

T4

T4A

T5

T6

Temp.
Range
(˚ºF)

664842

619662

574617

538572

502536

448500

421446

394419

358392

331356

322329

277320

250275

214248

187212

185

Temp.
Range
(°C)

351450

326350

301325

281300

261280

231260

216230

201215

181200

166180

161165

136160

121135

101120

86100

85

Accessories
Description

Catalog Number

GWMWG

Vandal Shield - UV stabilized polycarbonate. Can be used with guard.

GWMLS

Clear Replacement Lens

GWML

Lighting: Enclosed and Gasketed — Floodlight

Guard - Stainless steel plated

Dimensions

5.44”/
138.1 mm

14.00”/355.6 mm

12.13”/
308.0 mm

Lighting

V CSA Certification only.
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

1175

TVA Obstruction, Approach and Boundary Luminaires V

Lighting: Enclosed and Gasketed — Visual Signal

Lighting

CSA Certification Only

For use with Threaded Rigid Metal Conduit and IMC.
Class I, Division 2 versions available

Applications
•	 Transport Canada approved TVA490 series low intensity
obstruction, approach or boundary light.
•	 TVA490 series obstruction lights are suitable for use on
communication towers or other tall structures and buildings.

Features
•	 TVA obstruction lights are available with one or two lamps.
•	 Models are equipped with rainports in the globe holder which
keeps the wiring chamber dry.
•	 TVA obstruction lights are rugged cast aluminum construction.
•	 Two lamp fixtures are furnished with pre-wired sockets.
•	 Utilizes Type A-21 116 W clear traffic signal lamp.
•	 A corrosion resistant finish protects TVA fixtures. TVA490
obstruction lights are approved for use by Transport Canada.
•	 Engineered for easy and safe maintenance, TVA490 fixtures are
serviced without tools: 	
(1) The globe holder is secured with a captive thumb screw 	
(2) a one-eighth turn twist removes the globe and lobe holder	
(3) the assembly is hung from a safety chain freeing both hands
•	 Fresnel glass lenses and three lamp holder positions permit 	
use of TVA490 fixtures on structures below 50 feet/15.2 meters,
from 50 to 100 feet / 15.2 to 30.5 meters, and over 	
100 feet/30.5 meters.
•	 A plugged 1" side hub and a 1-1/4" bottom hub provide 	
conduit entry.
•	 Transfer and failure alarm relays for both one and two 	
lamp fixtures.
•	 Pilot light assembly contains a red pilot light to indicate lamp
failure.

Standard Materials
•	 TVA bodies: copperfree (4/10 of 1% max.) aluminum
•	 Lamp holders: porcelain
•	 Transfer and failure alarm, pilot light assembly: ferrous alloy
enclosure
•	 	Supply wire requirement: 90 ºC

TVA 1490

TVA 2490

Standard Finish
•	 TVA490: international orange epoxy clad finish
•	 Transfer failure alarm, pilot light assembly: triple coat – (1) zinc
electroplate, (2) chromate and (3) aluminum polymer enamel

Certifications and Compliances
•	 CSA Standard: C22.2 No. 250
•	 CSA Certified: 009349

V CSA Certification only.

1176

Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

TVA Obstruction, Approach and Boundary Luminaires V
CSA Certification Only

Lighting

For use with Threaded Rigid Metal Conduit and IMC.
Class I, Division 2 versions available

Hub Size (Inches)
Side
Bottom

Catalog Number

TVA490 Obstruction, Approach and Boundary Lights
Type A-21 Clear Traffic Signal Light 116 W
One Lamp Fixtures
Obstruction with Red Globe

—

1

TVA1490

Approach with Yellow Globe

—

1

TVA1490Y

Boundary with Clear Globe

—

1

TVA1490C

One Lamp Haz. Loc. Fixtures
Obstruction with Red Globe

—

1

TVA1490H

Approach with Yellow Globe

—

1

TVA1490YH

Boundary with Clear Globe

—

1

TVA1490CH

Two Lamp Fixtures
Obstruction with Red Globe

1

1-1/4 ①

TVA2490

Approach with Yellow Globe

1

1-1/4 ①

TVA2490Y

Boundary with Clear Globe

1

1-1/4 ①

TVA2490C

1

1-1/4 ①

TVA2490H

Two Lamp Haz. Loc. Fixtures
Obstruction with Red Globe
Approach with Yellow Globe

1

1-1/4 ①

TVA2490YH

Boundary with Clear Globe

1

1-1/4 ①

TVA2490CH

Single Lamp

—

1

TVA1400

Two Lamp

1

1-1/4

TVA2400

TVA490 Replacement Parts
Mounting Fittings
With Globe Holder and Lamp Socket

Globes
Fresnel
Red

V-990R

Aviation yellow

V-990Y

Clear

V-990C

Lamp Socket
Porcelain — Medium Base

V-1025

Globe Gasket
Neoprene

V-2055G

Wiring Chamber Cover
Cover assembly for two lamp fixture wiring
chamber. With gasket and screws

V-2010

① To order with 1/4" to 1" reducer in the bottom hub add suffix -RB100.

V CSA Certification only.
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

1177

Lighting: Enclosed and Gasketed — Visual Signal

Description

TVA Obstruction, Approach and Boundary Luminaire Accessories V

Lighting: Enclosed and Gasketed — Visual Signal

Lighting

CSA Certification Only

For use with Threaded Rigid Metal Conduit and IMC.
Class I, Division 2 versions available

Description

Hub Size
(Inches)

Catalog
Number

Lamp Failure Alarm
In the event of both lamps failing in the obstruction light an
alarm circuit is triggered.
Weather-proof enclosure is furnished with feed-thru hubs.
120 Vac, 50/60 Hz
Relay drops out at 0.6 amps.

1

FDC-32R2

In the event of a lamp failure, power is transferred to the
standby lamp and an alarm circuit is activated.
Weather-proof enclosure is furnished with feed-thru hubs.
120 Vac, 50/60 Hz
Relay drops out at 0.6 amps.

1

FDC-32R1

Connected to failure alarm to indicate lamp failure.
Red pilot light.
6S6 candelabra base lampholder.
Dead end enclosure.

1

FD-3J1

Transfer Relay and Lamp Failure Alarm

Pilot Light Assembly

Photocell

(Non-Hazardous)
Comes installed in FDO type enclosure, ready for installation.
120 V Only.

FS601

(Class I, Division 2)
As above, c/w Encapsulated Photocell for Hazardous Area
installation. 120 V Only.

FS601D2

Comes installed in FDO type enclosure, ready for installation.
2500 W Rated, 200 A Max. In-Rush FAA approved 30 FPM
Flash Rate.

TVA-FL

Flasher Assembly

V CSA Certification only.

1178

Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

TVA Obstruction, Approach and Boundary Luminaire Dimensions V
CSA Certification Only

Lighting

For use with Threaded Rigid Metal Conduit and IMC.

Dimensions (Inches/Millimeters)
A
B

Lighting: Enclosed and Gasketed — Visual Signal

Description

Catalog Number

One Lamp
Single

10.00/254.0

4.25/107.95

TVA1490

Twin

10.75/273.05

13.75/349.25

TVA2490

Two Lamp

V CSA Certification only.
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

1179

Stylmaster™ Strobe Luminaires

Lighting: Enclosed and Gasketed — Visual Signal

Lighting

Enclosed and Gasketed

NEC: Pendant Mount
Class I, Division 2, Groups A, B, C, D
Class II, Division 1 and 2, Groups E, F, G
Class III
NEMA 3R, 4
Marine Outside Type (Saltwater)

NEC: Ceiling and Wall Bracket Mount
Class I, Division 2, Groups A, B, C, D
NEMA 3R, 4

CEC: V
Class I, Division 2, Groups A, B, C, D
Class II, Division 1 and 2, Groups E, F, G
Class III
CSA Enclosure 3

Applications
•	 Enclosed and gasketed fixtures suitable for use in:
— Marine and wet locations
— Industrial processing
— Chemical processing
— Areas where flammable gases and vapors are present under
conditions defined by NEC Class I, Division 2; Class II,
Division 1 and 2; and Class III
•	 For use in areas where audible signals cannot be heard.
•	 Used to warn of unsafe conditions and other communication
needs.
•	 Fixtures are also suited for use in non-hazardous areas where
there are:
	 — Severe weather conditions
	 — Excessive moisture, dirt, dust
	 — Corrosive atmospheres
	 — High ambient temperatures are encountered
•	 Typical applications include:
	 — Pulp and paper mills
	 — Processing plants
	 — Chemical plants
	 — Oil refineries
	 — Foundries
	 — Manufacturing plants
	 — Storage areas
	 	— Marine applications

Features
•	 Modern styling, with clean-line mounting hood and prismatic
glass globe, plus optional guard.
•	 Globe seats firmly against silicone gasket in mounting
hood to keep out dirt and moisture. Full threads eliminate “cross
threading.”
•	 Optional guard protects glass from damage and has 	
exclusive snap-on attachment feature for quick installation 	
and fast servicing.
•	 Fixtures operate safely in high ambient temperatures.
•	 Strobe: 65 flashes per minute. 800,000 peak candlepower.
•	 Fixtures are complete with lamp.
•	 Lens available in five colors: red, amber, blue, green and 	
clear (factory installed).
•	 Heat- and impact-resistant globes have smooth
dust-resistant exterior.
•	 Fixture is suitable for mounting globe up or globe down utilizing
pendant, ceiling or wall bracket type mounts.
•	 Minimum operating temperature is -13 °F/-25 °C.

Fixtures are suitable for mounting in any position – including globe up or
globe down – utilizing pendant, ceiling or wall bracket type mounts.

Standard Materials
•	 Mounting hoods: copperfree (4/10 of 1% max.) aluminum
•	 Guards: pressure cast copperfree (4/10 of 1% max.) aluminum
•	 Globes: prismatic glass

Standard Finish
•	 Mounting hoods and guards: powder coat epoxy

Certifications and Compliances
•	
•	
•	
•	

UL Standard: UL 1203, UL 1638
UL Listed: E207738
CSA Standard: C22.2 No. 25
cUL Listed: E207738

V CSA Certification only.

1180

Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

Stylmaster™ Strobe Luminaires
Enclosed and Gasketed

NEC: Ceiling and Wall Bracket Mount
Class I, Division 2, Groups A, B, C, D
NEMA 3R, 4

Lighting

NEC: Pendant Mount
Class I, Division 2, Groups A, B, C, D
Class II, Division 1 and 2, Groups E, F, G
Class III
NEMA 3R, 4
Marine Outside Type (Saltwater)

CEC: V
Class I, Division 2, Groups A, B, C, D
Class II, Division 1 and 2, Groups E, F, G
Class III
CSA Enclosure 3

Lighting: Enclosed and Gasketed — Visual Signal

Order using catalog numbering guide below or select catalog number from tables on following pages.
Catalog Numbering Guide For VP Stylmaster Strobe Luminaires
VP

A

S

Series:
VP - Stylmaster	

75

120AC

Lamp Type:
S - Strobe

CL

G
Options:
G - Guard

Voltage Current:
120AC - 120 Vac
240AC - 240 Vac
1248DC - 12-48 Vdc
24PDC - 24 Vdc ①
250DC - 250 Vdc

Mounting Hood:
A - Pendant
X - Ceiling
WB - Wall Bracket

Hub Size:
75 - 3/4”

Globe:
CL - Clear
AM - Amber
BL - Blue
GR - Green
RE - Red

Technical Data: Thermal Suitability of Stylmaster Strobe
Operating Temperatures
Ambient
Temp. (°F/°C)
104/40
131/55
149/65

Class I, Division 2 Groups A,B,C,D
Pendant, Ceiling and Wall Bracket
T2A
T2
T1

Class II, Division 1& 2 and Class III
Pendant Mount
T4A
T4A
T4

Operating Temperatures Represent the Maximum Internal Temperature for Class I, Division 2 Locations and
Maximum Surface Temperature Under Dust Blanket for Class II, Division 1 Locations.
“T”
Number

T1

350

325

T2

T2A

T2B

T2C

T2D

T3

T3A

T3B

T3C

T4

T4A

T5

T6

Temp.
Range
(˚ºF)

664842

619662

574617

538572

502536

448500

421446

394419

358392

331356

322329

277320

250275

214248

187212

185

Temp
Range
(°C)

351-	
450

326-	
350

301-	
325

281-	
300

261-	
280

231-	
260

216-	
230

201-	
215

181-	
200

166-	
180

161165

136-	
160

121-	
135

101-	
86-100
120

85

NOTE: The maximum operating temperature of the fixture must not exceed the ignition temperature of the gas, vapor or dust to be encountered per the National
Electrical Code and the Canadian Electrical Code.
① Diode Polarized (current limiter supplied as standard).
V CSA Certification only.
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

1181

Stylmaster™ Strobe Luminaires

Lighting: Enclosed and Gasketed — Visual Signal

Lighting

Enclosed and Gasketed

NEC: Pendant Mount
Class I, Division 2, Groups A, B, C, D
Class II, Division 1 and 2, Groups E, F, G
Class III
NEMA 3R, 4
Marine Outside Type (Saltwater)

NEC: Ceiling and Wall Bracket Mount
Class I, Division 2, Groups A, B, C, D
NEMA 3R, 4

CEC: V
Class I, Division 2, Groups A, B, C, D
Class II, Division 1 and 2, Groups E, F, G
Class III
CSA Enclosure 3

Volts

Wt. (lbs/kg)

Catalog Number ①

Pendant — Rigid Conduit One Hub 3/4” NPT
VPAS75120ACCL

120 Vac

VPAS75240ACCL

240 Vac
250 Vdc

4.5/2.0

VPAS75250DCCL

12-48 Vdc

VPAS751248DCCL

24 Vdc

VPAS7524PDCCL ②

120 Vac

VPXS75120ACCL

240 Vac

VPXS75240ACCL

Ceiling — Rigid Conduit Four Hubs 3/4” NPT Three Close-Up Plugs

250 Vdc

5.3/2.4

VPXS75250DCCL

12-48 Vdc

VPXS751248DCCL

24 Vdc

VPXS7524PDCCL ②

120 Vac

VPWBS75120ACCL

Wall Bracket — Rigid Conduit Four Hubs 3/4” NPT Three Close-Up Plugs
VPWBS75240ACCL

240 Vac
250 Vdc

6.4/2.9

VPWBS75250DCCL

12-48 Vdc

VPWBS751248DCCL

24 Vdc

VPWBS7524DCCL ②

Optional Aluminum Guard

1.0/0.5

VPGU-1

① Catalog numbers shown are supplied with clear lens. To order colored lens, replace the last digits of catalog number CL with AM for amber, BL for blue,
GR for green or RE for red.
② Diode Polarized (current limiter supplied as standard).
V CSA Certification only.

1182

Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

Stylmaster™ Strobe Luminaire Replacement Parts and Dimensions
Enclosed and Gasketed

Lighting

Replacement Lamps

Fixture Type

Lamp Type

Voltage

Base Type

Strobe

Xenon

All

Octal Socket

Catalog Number
S865

S865
Glass Globe

Catalog
Number

Clear

VPGL-1HR

Replacement Globes and Inserts

Insert
(in addition to Glass Globe)
Clear

59606060000

Amber

59606060001

Blue

59606060002

Green

59606060003

Red

59606060004

Dimensions

Pendant Mount

Ceiling Mount

7.00"/
177.8 mm

Wall Mount
10.63"/
270.0 mm
8.75"/
222.3 mm
5.25"/
133.4mm

7.00"/
177.8 mm
4.06"/
103.1mm

3.56"/
90.4 mm

3.05"/
77.5 mm

3.31"/
84.1mm

9.13"/
231.9mm

9.13"/
231.9mm

9.39"/
238.5 mm

6.08"/
154.4mm

4.75”/
120.7 mm

Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

1.88” /
47.8 mm
4.06” /
103.1 mm

4.75”/
120.7 mm

1.88” /
47.8 mm
4.06” /
103.1 mm

1183

Lighting: Enclosed and Gasketed — Visual Signal

Replacement Parts

Mercmaster™ III Emergency Battery Pack

Enclosed and Gasketed. For Hazardous and Wet Locations
Simultaneous Exposure
Class I, Division 2, Class II, Division 1
Class I, Division 2, Group A, B, C, D
Class II, Division 1 and 2, Groups E, F, G
Class III

Wet Locations
NEMA 4X

Lighting: Enclosed and Gasketed — Emergency

Lighting

Applications
•	 Auxiliary (emergency) lighting should be used to provide a
lighted means of egress for personnel in walkways, catwalks,
stairs, doorways, tunnels, ramps and aisles.
•	 Auxiliary (emergency) lighting should be used to provide 	
“instant on” illumination during power failures.
•	 Enclosed and gasketed fixtures are suitable for normal
and emergency use in wet locations and in a wide range
of industrial, chemical processing and other areas where
flammable gases and vapors or combustible dusts are 	
present under conditions defined by NEC Class I, Division 2; 	
Class II, Division 1 and 2; and Class III.
•	 Suitability includes listing for normal and emergency use 	
where there may be simultaneous exposure to combustible
dusts and flammable gases and vapors.
•	 Fixtures are also well suited for normal and emergency 	
use in non-hazardous areas where severe weather 	
conditions, excessive moisture, dirt, dust or corrosive
atmospheres are encountered.
•	 Typical applications include pulp and paper mills, processing
plants, chemical plants, oil refineries, foundries, manufacturing
plants and storage areas.

Features
•	 Modular design allows scores of fixture component
combinations to meet installation and lighting needs.  
•	 Choice of optical assemblies: (1) prismatic globe; (2) enclosed
reflector with sealed lens; and (3) Type V or Type II closed
prismatic refractor, with or without guard.
•	 Fluorescent light source reduces energy costs.
•	 Fluorescent lamp life of 10,000 hours reduces relamping 	
costs compared to incandescent.
•	 Mounting hoods include cone-shaped pendant, standard
pendant, ceiling and wall (tapped for 3/4” or 1” NPT), 25° 	
angle stanchion and straight stanchion (both tapped for 	
1-1/4” or 1-1/2” NPT).
•	 Cone hood fixtures for pendant mounting shed dust, dirt 	
and combustible fibers. Inhibits build-up that “insulates” 	
fixture and slows heat transfer.  Also provides increased 	
surface area for more effective heat dissipation.
•	 Reflector choice includes standard dome and 30° angle 	
types, both made of fiberglass reinforced white polyester.
Highly resistant to unusually corrosive applications. Reflectors
are vented for cooler, dirt-free operation and maintained lumen
output. They secure to ballast housing with stainless steel
screws, threading into stainless steel inserts.
•	 For high corrosion resistance, fixture housing, mounting 	
hoods and guards are diecast copperfree (4/10 of 1% max.)
aluminum with baked epoxy finish, electrostatically applied for
uniformity. 	
All exposed hardware is stainless steel.
•	 Hinge has high lip for added safety during installation
and servicing. Hinge and bolt construction assures 360°
compression at all points on ballast housing gasket for 	
positive sealing. Swing-away design of captive bolt and 	
nut simplifies servicing.
•	 Body gaskets and globe gaskets are high-temperature 	
silicone rubber.
•	 All Mercmaster III mounting hoods have provision for easy 	
field installation of fuses in fixtures (see fuse kit listing in this
catalog section).

1184

Prismatic Glass Globe

12” Glass Refractor

Enclosed Reflector

•	 “Instant on” nature of the fluorescent light source prevents the
possibility of a complete blackout due to power failure.
•	 Fixture (26 W or 52 W) is available for emergency operation (one
battery pack provides illumination only during power outage).
•	 Fixture (26 W or 52 W) is available for continuous operation 	
(one AC ballast permits illumination when AC power is on and
one battery pack permits illumination when AC power 	
is interrupted).
•	 Fixture (26 W, 52 W, 64 W or 84 W) is available for 	
semi-continuos operation (one AC ballast permits illumination
when power is on and one battery pack permits one lamp
illumination when AC power is interrupted).
•	 For electrical protection, a ground wire is provided on each
Mercmaster to bond hood and ballast housing.
•	 Minimum operating temperature: 0 °C/32 °F.
•	 Maximum operating temperature: 40 °C/104 °F.

Battery Pack Information
•	
•	
•	
•	

Sealed, maintenance-free, high-temperature nickel-cadmium.
Solid state chargers sealed within the ballast case.
10 year life expectancy.
Wiring instructions for “Push-To-Test” button are supplied 	
with fixture.
•	 Remote “Push-To-Test” switch is available to verify emergency
operation (order separately, see F3-82).
•	 Red indicator light is provided with each battery pack to indicate
when the battery is charging.

Standard Materials
•	 Mounting hoods, ballast bodies and guard: diecast 	
cooper-free aluminum (less than 4/10 of 1%)
•	 Exposed hardware: stainless steel; latch assemblies have
stainless steel bolt and captive nut; reflectors and guards attach
with stainless steel screws threading into stainless steel inserts
•	 Reflectors: fiberglass reinforced white polyester
•	 Globe: heat- and im­pact-re­sist­ant in­ter­nal­ly flut­ed glass
•	 Refractors: pris­mat­ic glass
•	 Enclosed re­flec­tor: etched alu­mi­num with sealed, 	
tem­pered heat- and im­pact-re­sist­ant lens
•	 Guards: stain­less steel
•	 Breather: stainless steel

Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

Mercmaster™ III Emergency Battery Pack

Enclosed and Gasketed. For Hazardous and Wet Locations
Simultaneous Exposure
Class I, Division 2, Class II, Division 1
Class I, Division 2, Group A, B, C, D
Class II, Division 1 and 2, Groups E, F, G
Class III

Wet Locations
NEMA 4X

Standard Finishes

Certifications and Compliances
•	 UL Standard: UL 1598, UL 924, UL 844
•	 UL Listed: E10444
•	 NFPA101, Life Safety Code
Lighting

•	 Mounting hoods, ballast bodies, guards: baked gray 	
epoxy-clad finish, electrostatically applied for complete, 	
uniform surface protection
•	 Reflectors: white polyester finish

Options
•	 Fuses can be field-installed on Mercmaster III fixtures. Kit
includes fuse block, wire connectors and screws for attaching to
mounting hood.

Lighting: Enclosed and Gasketed — Emergency

Order using catalog numbering guide below or select catalog number from tables on following pages.
Catalog Numbering Guide
KP

A

Series:
KP - Class I,
Division 2
Groups A,B,C,D
Class II, Division 1
and 2
Groups E,F,G
Class III

F
Lamp Type:
F - Fluorescent

Mounting Hood:
A - Pendant
C - Ceiling
D - Pendant Cone
F - Flexible Pendant
R - 90° Stanchion
S - 25° Stanchion
W - Wall

26

C

2

Circuit Type:
C - Continuous
Operation
(provided with 1
AC Ballast and 1
Battery Pack). 	
26 W and 52 W
E- Emergency
Operation
(provided with 1
Battery Pack). 	
26 W and 52 W
only
S -  SemiContinuous
(provided with 1
AC Ballast and 1
Battery Pack).
	 26 W, 52 W, 64 W
and 84 W

Lamp Wattage:
26 - 26 W (Two 13 W Lamps)
52 - 52 W (Two 26 W Lamps)
64 - 64 W (Two 32 W Lamps)
84 - 84 W (Two 42 W Lamps)

Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

Hub Size:
2 - 3/4”
3 - 1”
4 - 1-1/4”
5 - 1-1/2”

G4

G

Optic:
G4 - Globe
R - Enclosed
Reflector with
Sealed Lens
J2 - NEMA II
Refractor
J5 - NEMA V
Refractor

BU

L

Voltage:
120 through 277 Volt
50/60 Hz

Guard Option:
G - Guard
N - No Guard

Lamps:
L - Lamps provided

1185

Mercmaster™ III Emergency Battery Pack

Enclosed and Gasketed. For Hazardous and Wet Locations
Simultaneous Exposure
Class I, Division 2, Class II, Division 1
Class I, Division 2, Group A, B, C, D
Class II, Division 1 and 2, Groups E, F, G
Class III

Wet Locations
NEMA 4X

Lighting: Enclosed and Gasketed — Emergency

Lighting

Illustrated Features

Vented Reflectors
Reflectors are thick, tough fiberglass-	
reinforced white polyester, vented for
cooler operation. Quickly attach with
furnished stainless steel screws.
Aluminum Inner Reflector
Solid aluminum inner reflector improves
photometric efficiency.
Epoxy Finish
Ballast housing, hoods and guards are
copperfree aluminum with epoxy powder
coat finish.

"Safety" High
Hinge
Extra-high hinge
provides additional
protection against
accidental
ballast housing
disengagement
during installation
or maintenance.

Stainless Steel
Latch Assembly
Captive, stainless
steel latch assembly
bolt and nut closes
securely, resists
attack of corrosive
atmospheres.
Swing-away design
simplifies servicing.

Stainless Steel Inserts
Ballast bodies have stainless steel
threaded inserts to receive stainless steel
screws for reflectors and guard. Prevents
"freezing”, allowing guards and reflectors
to be easily removed and replaced at any
time, without damage to the housing.

Hood/Ballast Gasket
Silicone rubber gasket seals out moisture,
dirt and dust. Stays flexible, withstands
high temperatures. Closure design
assures uniform gasket compression.
Electrical Protection
Ground wire provided to bond mounting
hood to ballast housing.

Prismatic Glass Globes, Refractors
and Enclosed Reflector
Heat-resistant globes, refractors and
enclosed reflector thread into ballast
housing and seal against a high
temperature silicone rubber gasket.

Cooler Operating Cone Hood
Larger sloped surface sheds dusts, dirt
and combustible fibers providing better
heat dissipation.

Fuses
Two screws secure fuse kit to mounting
boss in any Mercmaster mounting hood.
Fuse included.

1186

Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

Mercmaster™ III Emergency Battery Pack Technical Data
Enclosed and Gasketed. For Hazardous and Wet Locations
Simultaneous Exposure
Class I, Division 2, Class II, Division 1
Class I, Division 2, Group A, B, C, D
Class II, Division 1 and 2, Groups E, F, G
Class III

Wet Locations
NEMA 4X

Electrical Specification for AC Operation
Frequency (Hz)

Type of Ballast

Line Amps (A)

Maximum Wattage (W/W)

Catalog Number

26 W (2X 13 W)

120-277

50/60

Electronic (PLT)

0.26-0.11

30/30

KPBC26FBU

26 W (2X 13 W)

120-277

50/60

Electronic (PLT)

0.26-0.11

30/30

KPBE26FBU

26 W (2X 13 W)

120-277

50/60

Electronic (PLT)

0.26-0.11

30/30

KPBS26FBU

52 W (2X 26 W)

120-277

50/60

Electronic (PLT)

0.46-0.20

56/55

KPBC52FBU

52 W (2X 26 W)

120-277

50/60

Electronic (PLT)

0.46-0.20

56/55

KPBE52FBU

52 W (2X 26 W)

120-277

50/60

Electronic (PLT)

0.46-0.20

56/55

KPBS52FBU

64 W (2X 32 W)

120-277

50/60

Electronic (PLT)

0.58-0.26

69/67

KPBS64FBU

84 W (2X 42 W)

120-277

50/60

Electronic (PLT)

0.76-0.32

91/90

KPBS84FBU

Thermal Performance of Mercmaster III Emergency Battery Pack Fixtures
Lamp
Watts

Ambient
Temp.
(°F/°C)

Group

26 W (2 x 13 W)

104/40

A,B,C,D

52 W (2 x 26 W)

104/40

64 W (2 x 32 W)
84 W (2 x 42 W)

Hazardous
Rating

Class I, Division 2

Class II, Division 1

Simultaneous
Exposure 	
Class I, Division 2 /
Class II, Division 1

Refractor

Enclosed
Reflector

Supply Wire
Suitability
(°F/°C)

T2D

T2D

167/75

T2D

T2D

T2D

167/75

T2D

T2D

T2D

T2D

167/75

T2D

T2D

T2D

T2D

167/75

E,F,G

T3B

T3B

T4

T4A

194/90

104/40

E,F,G

T3B

T3B

T4

T4A

194/90

64 W (2 x 32 W)

104/40

E,F,G

T3B

T3B

T4

T4A

194/90

84 W (2 x 42 W)

104/40

E,F,G

T3B

T3B

T4

T4A

194/90

26 W (2 x 13 W)

104/40

—

T1

T1

T2

T2B

230/110

52 W (2 x 26 W)

104/40

—

T1

T1

T2

T2B

230/110

64 W (2 x 32 W)

104/40

—

T1

T1

T2

T2B

230/110

84 W (2 x 42 W)

104/40

—

T1

T1

T2

T2B

230/110

Globe

Globe w/
Reflector

T2D

T2D

A,B,C,D

T2D

104/40

A,B,C,D

104/40

A,B,C,D

26 W (2 x 13 W)

104/40

52 W (2 x 26 W)

“T” Numbers Represent the Maximum Lamp Temperature for Class I, Division 2 Locations and Maximum
Surface Temperature Under Dust Blanket for Class II, Division 1 Locations.
“T”
Number

T1

350

325

T2

T2A

T2B

T2C

T2D

T3

T3A

T3B

T3C

T4

T4A

T5

T6

Temp.
Range
(˚ºF)

664842

619662

574617

538572

502536

448500

421446

394419

358392

331356

322329

277320

250275

214248

187212

185

Temp
Range
(°C)

351450

326350

301325

281300

261280

231260

216230

201215

181200

166180

161165

136160

121135

101120

86-100

85

Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

1187

Lighting: Enclosed and Gasketed — Emergency

Line Voltage (V)

Lighting

Fixture Wattage

Mercmaster™ III Emergency Battery Pack

Enclosed and Gasketed. For Hazardous and Wet Locations
Simultaneous Exposure
Class I, Division 2, Class II, Division 1
Class I, Division 2, Group A, B, C, D
Class II, Division 1 and 2, Groups E, F, G
Class III

Lighting: Enclosed and Gasketed — Emergency

Lighting

Lamp Hub Size
Watts (Inches)
Pendant ➍

Pendant Cone

Ceiling

Wall

90° Stanchion

25° Stanchion

Wet Locations
NEMA 4X

Mode of
Operation

Volts

Hz

with Globe ➊➋

Catalog Numbers
with Type V 12” Refractor
➊➋➌

with Enclosed
Reflector ➊➋➌

26

3/4

Continuous

120-277

50/60

KPAF26C2G4NBUL

KPAF26C2J5NBUL

KPAF26C2RNBUL

26

1

Continuous

120-277

50/60

KPAF26C3G4NBUL

KPAF26C3J5NBUL

KPAF26C3RNBUL

26

3/4

Semi-Continuous 120-277

50/60

KPAF26S2G4NBUL

KPAF26S2J5NBUL

KPAF26S2RNBUL

26

1

Semi-Continuous 120-277

50/60

KPAF26S3G4NBUL

KPAF26S3J5NBUL

KPAF26S3RNBUL

26

3/4

120-277

50/60

KPAF26E2G4NBUL

KPAF26E2J5NBUL

KPAF26E2RNBUL

Emergency

26

1

Emergency

120-277

50/60

KPAF26E3G4NBUL

KPAF26E3J5NBUL

KPAF26E3RNBUL

26

3/4

Continuous

120-277

50/60

KPDF26C2G4NBUL

KPDF26C2J5NBUL

KPDF26C2RNBUL

26

1

Continuous

120-277

50/60

KPDF26C3G4NBUL

KPDF26C3J5NBUL

KPDF26C3RNBUL

26

3/4

Semi-Continuous 120-277

50/60

KPDF26S2G4NBUL

KPDF26S2J5NBUL

KPDF26S2RNBUL

26

1

Semi-Continuous 120-277

50/60

KPDF26S3G4NBUL

KPDF26S3J5NBUL

KPDF26S3RNBUL

26

3/4

KPDF26E2G4NBUL

KPDF26E2J5NBUL

KPDF26E2RNBUL

Emergency

120-277

50/60

26

1

Emergency

120-277

50/60

KPDF26E3G4NBUL

KPDF26E3J5NBUL

KPDF26E3RNBUL

26

3/4

Continuous

120-277

50/60

KPCF26C2G4NBUL

KPCF26C2J5NBUL

KPCF26C2RNBUL

26

1

Continuous

120-277

50/60

KPCF26C3G4NBUL

KPCF26C3J5NBUL

KPCF26C3RNBUL

26

3/4

Semi-Continuous 120-277

50/60

KPCF26S2G4NBUL

KPCF26S2J5NBUL

KPCF26S2RNBUL

26

1

Semi-Continuous 120-277

50/60

KPCF26S3G4NBUL

KPCF26S3J5NBUL

KPCF26S3RNBUL

26

3/4

KPCF26E2G4NBUL

KPCF26E2J5NBUL

KPCF26E2RNBUL

Emergency

120-277

50/60

26

1

Emergency

120-277

50/60

KPCF26E3G4NBUL

KPCF26E3J5NBUL

KPCF26E3RNBUL

26

3/4

Continuous

120-277

50/60

KPWF26C2G4NBUL

KPWF26C2J5NBUL

KPWF26C2RNBUL

Continuous

26

1

120-277

50/60

KPWF26C3G4NBUL

KPWF26C3J5NBUL

KPWF26C3RNBUL

26

3/4

Semi-Continuous 120-277

50/60

KPWF26S2G4NBUL

KPWF26S2J5NBUL

KPWF26S2RNBUL

26

1

Semi-Continuous 120-277

50/60

KPWF26S3G4NBUL

KPWF26S3J5NBUL

KPWF26S3RNBUL

26

3/4

Emergency

120-277

50/60

KPWF26E2G4NBUL

KPWF26E2J5NBUL

KPWF26E2RNBUL

26

1

Emergency

120-277

50/60

KPWF26E3G4NBUL

KPWF26E3J5NBUL

KPWF26E3RNBUL

26

1-1/4

Continuous

120-277

50/60

KPRF26C4G4NBUL

KPRF26C4J5NBUL

KPRF26C4RNBUL

26

1-1/2

Continuous

120-277

50/60

KPRF26C5G4NBUL

KPRF26C5J5NBUL

KPRF26C5RNBUL

26

1-1/4 Semi-Continuous 120-277

50/60

KPRF26S4G4NBUL

KPRF26S4J5NBUL

KPRF26S4RNBUL

26

1-1/2 Semi-Continuous 120-277

50/60

KPRF26S5G4NBUL

KPRF26S5J5NBUL

KPRF26S5RNBUL

26

1-1/4

Emergency

120-277

50/60

KPRF26E4G4NBUL

KPRF26E4J5NBUL

KPRF26E4RNBUL

26

1-1/2

Emergency

120-277

50/60

KPRF26E5G4NBUL

KPRF26E5J5NBUL

KPRF26E5RNBUL

26

1-1/4

Continuous

120-277

50/60

KPSF26C4G4NBUL

KPSF26C4J5NBUL

KPSF26C4RNBUL

26

1-1/2

Continuous

120-277

50/60

KPSF26C5G4NBUL

KPSF26C5J5NBUL

KPSF26C5RNBUL

26

1-1/4 Semi-Continuous 120-277

50/60

KPSF26S4G4NBUL

KPSF26S4J5NBUL

KPSF26S4RNBUL

26

1-1/2 Semi-Continuous 120-277

50/60

KPSF26S5G4NBUL

KPSF26S5J5NBUL

KPSF26S5RNBUL

26

1-1/4

Emergency

120-277

50/60

KPSF26E4G4NBUL

KPSF26E4J5NBUL

KPSF26E4RNBUL

26

1-1/2

Emergency

120-277

50/60

KPSF26E5G4NBUL

KPSF26E5J5NBUL

KPSF26E5RNBUL

NOTE: “Continuous operation” means 2 lamps operate when AC power is present and continue to operate during AC power failure. “Emergency operation”
means lamps do not operate when AC power is present, but 2 lamps operate from the DC battery pack only during AC power failure. “Semi-continuous” means 2
lamps operate when AC power is present and 1 lamp continues to operate during AC power failure.
➊ For fixtures with guard, substitute G for N before adding voltage suffix.
➋ Lamp included as standard.
➌ To order fixture with NEMA type 2 refractor, change final digit J5 in catalog number to J2.
➍ One hub, rigid or flexible mounting.

1188

Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

Mercmaster™ III Emergency Battery Pack

Enclosed and Gasketed. For Hazardous and Wet Locations
Simultaneous Exposure
Class I, Division 2, Class II, Division 1
Class I, Division 2, Group A, B, C, D
Class II, Division 1 and 2, Groups E, F, G
Class III

Lamp Hub Size
Watts (Inches)

Ceiling

Wall

90° Stanchion

25° Stanchion

Volts

Hz

with Globe ➊➋

Catalog Numbers
with Type V 12” Refractor
➊➋➌

with Enclosed
Reflector ➊➋➌

52

3/4

Continuous

120-277

50/60

KPAF52C2G4NBUL

KPAF52C2J5NBUL

KPAF52C2RNBUL

52

1

Continuous

120-277

50/60

KPAF52C3G4NBUL

KPAF52C3J5NBUL

KPAF52C3RNBUL

52

3/4

Semi-Continuous 120-277

50/60

KPAF52S2G4NBUL

KPAF52S2J5NBUL

KPAF52S2RNBUL

52

1

Semi-Continuous 120-277

50/60

KPAF52S3G4NBUL

KPAF52S3J5NBUL

KPAF52S3RNBUL

52

3/4

KPAF52E2G4NBUL

KPAF52E2J5NBUL

KPAF52E2RNBUL

Emergency

120-277

50/60

52

1

Emergency

120-277

50/60

KPAF52E3G4NBUL

KPAF52E3J5NBUL

KPAF52E3RNBUL

52

3/4

Continuous

120-277

50/60

KPDF52C2G4NBUL

KPDF52C2J5NBUL

KPDF52C2RNBUL

52

1

Continuous

120-277

50/60

KPDF52C3G4NBUL

KPDF52C3J5NBUL

KPDF52C3RNBUL

52

3/4

Semi-Continuous 120-277

50/60

KPDF52S2G4NBUL

KPDF52S2J5NBUL

KPDF52S2RNBUL

52

1

Semi-Continuous 120-277

50/60

KPDF52S3G4NBUL

KPDF52S3J5NBUL

KPDF52S3RNBUL

52

3/4

KPDF52E2G4NBUL

KPDF52E2J5NBUL

KPDF52E2RNBUL

Emergency

120-277

50/60

52

1

Emergency

120-277

50/60

KPDF52E3G4NBUL

KPDF52E3J5NBUL

KPDF52E3RNBUL

52

3/4

Continuous

120-277

50/60

KPCF52C2G4NBUL

KPCF52C2J5NBUL

KPCF52C2RNBUL

52

1

Continuous

120-277

50/60

KPCF52C3G4NBUL

KPCF52C3J5NBUL

KPCF52C3RNBUL

52

3/4

Semi-Continuous 120-277

50/60

KPCF52S2G4NBUL

KPCF52S2J5NBUL

KPCF52S2RNBUL

52

1

Semi-Continuous 120-277

50/60

KPCF52S3G4NBUL

KPCF52S3J5NBUL

KPCF52S3RNBUL

52

3/4

Emergency

120-277

50/60

KPCF52E2G4NBUL

KPCF52E2J5NBUL

KPCF52E2RNBUL

52

1

Emergency

120-277

50/60

KPCF52E3G4NBUL

KPCF52E3J5NBUL

KPCF52E3RNBUL

52

3/4

Continuous

120-277

50/60

KPWF52C2G4NBUL

KPWF52C2J5NBUL

KPWF52C2RNBUL

Continuous

52

1

120-277

50/60

KPWF52C3G4NBUL

KPWF52C3J5NBUL

KPWF52C3RNBUL

52

3/4

Semi-Continuous 120-277

50/60

KPWF52S2G4NBUL

KPWF52S2J5NBUL

KPWF52S2RNBUL

52

1

Semi-Continuous 120-277

50/60

KPWF52S3G4NBUL

KPWF52S3J5NBUL

KPWF52S3RNBUL

52

3/4

Emergency

120-277

50/60

KPWF52E2G4NBUL

KPWF52E2J5NBUL

KPWF52E2RNBUL

52

1

Emergency

120-277

50/60

KPWF52E3G4NBUL

KPWF52E3J5NBUL

KPWF52E3RNBUL

52

1-1/4

Continuous

120-277

50/60

KPRF52C4G4NBUL

KPRF52C4J5NBUL

KPRF52C4RNBUL

52

1-1/2

Continuous

120-277

50/60

KPRF52C5G4NBUL

KPRF52C5J5NBUL

KPRF52C5RNBUL

52

1-1/4 Semi-Continuous 120-277

50/60

KPRF52S4G4NBUL

KPRF52S4J5NBUL

KPRF52S4RNBUL

52

1-1/2 Semi-Continuous 120-277

50/60

KPRF52S5G4NBUL

KPRF52S5J5NBUL

KPRF52S5RNBUL

52

1-1/4

Emergency

120-277

50/60

KPRF52E4G4NBUL

KPRF52E4J5NBUL

KPRF52E4RNBUL

52

1-1/2

Emergency

120-277

50/60

KPRF52E5G4NBUL

KPRF52E5J5NBUL

KPRF52E5RNBUL

52

1-1/4

Continuous

120-277

50/60

KPSF52C4G4NBUL

KPSF52C4J5NBUL

KPSF52C4RNBUL

52

1-1/2

Continuous

120-277

50/60

KPSF52C5G4NBUL

KPSF52C5J5NBUL

KPSF52C5RNBUL

52

1-1/4 Semi-Continuous 120-277

50/60

KPSF52S4G4NBUL

KPSF52S4J5NBUL

KPSF52S4RNBUL

52

1-1/2 Semi-Continuous 120-277

50/60

KPSF52S5G4NBUL

KPSF52S5J5NBUL

KPSF52S5RNBUL

52

1-1/4

Emergency

120-277

50/60

KPSF52E4G4NBUL

KPSF52E4J5NBUL

KPSF52E4RNBUL

52

1-1/2

Emergency

120-277

50/60

KPSF52E5G4NBUL

KPSF52E5J5NBUL

KPSF52E5RNBUL

NOTE: “Continuous operation” means 2 lamps operate when AC power is present and continue to operate during AC power failure. “Emergency operation”
means lamps do not operate when AC power is present, but 2 lamps operate from the DC battery pack only during AC power failure. “Semi-continuous” means 2
lamps operate when AC power is present and 1 lamp continues to operate during AC power failure.
➊ For fixtures with guard, substitute G for N before adding voltage suffix.
➋ Lamp included as standard.
➌ To order fixture with NEMA type 2 refractor, change final digit J5 in catalog number to J2.
➍ One hub, rigid or flexible mounting.
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

1189

Lighting: Enclosed and Gasketed — Emergency

Pendant Cone

Mode of
Operation

Lighting

Pendant ➍

Wet Locations
NEMA 4X

Mercmaster™ III Emergency Battery Pack

Enclosed and Gasketed. For Hazardous and Wet Locations
Simultaneous Exposure
Class I, Division 2, Class II, Division 1
Class I, Division 2, Group A, B, C, D
Class II, Division 1 and 2, Groups E, F, G
Class III

Lighting: Enclosed and Gasketed — Emergency

Lighting

Lamp Hub Size
Watts (Inches)
Pendant ➍

Pendant Cone

Ceiling

Wall

90° Stanchion

25° Stanchion

Wet Locations
NEMA 4X

Mode of
Operation

Volts

Hz

with Globe ➊➋

Catalog Numbers
with Type V 12” Refractor
➊➋➌

with Enclosed
Reflector ➊➋➌

64

3/4

Semi-Continuous 120-277

50/60

KPAF64S2G4NBUL

KPAF64S2J5NBUL

KPAF64S2RNBUL

64

1

Semi-Continuous 120-277

50/60

KPAF64S3G4NBUL

KPAF64S3J5NBUL

KPAF64S3RNBUL

64

3/4

Semi-Continuous 120-277

50/60

KPDF64S2G4NBUL

KPDF64S2J5NBUL

KPDF64S2RNBUL

64

1

Semi-Continuous 120-277

50/60

KPDF64S3G4NBUL

KPDF64S3J5NBUL

KPDF64S3RNBUL

64

3/4

Semi-Continuous 120-277

50/60

KPCF64S2G4NBUL

KPCF64S2J5NBUL

KPCF64S2RNBUL

64

1

Semi-Continuous 120-277

50/60

KPCF64S3G4NBUL

KPCF64S3J5NBUL

KPCF64S3RNBUL

64

3/4

Semi-Continuous 120-277

50/60

KPWF64S2G4NBUL

KPWF64S2J5NBUL

KPWF64S2RNBUL

64

1

Semi-Continuous 120-277

50/60

KPWF64S3G4NBUL

KPWF64S3J5NBUL

KPWF64S3RNBUL

64

1-1/4 Semi-Continuous 120-277

50/60

KPRF64S4G4NBUL

KPRF64S4J5NBUL

KPRF64S4RNBUL

64

1-1/2 Semi-Continuous 120-277

50/60

KPRF64S5G4NBUL

KPRF64S5J5NBUL

KPRF64S5RNBUL

64

1-1/4 Semi-Continuous 120-277

50/60

KPSF64S4G4NBUL

KPSF64S4J5NBUL

KPSF64S4RNBUL

64

1-1/2 Semi-Continuous 120-277

50/60

KPSF64S5G4NBUL

KPSF64S5J5NBUL

KPSF64S5RNBUL

NOTE: “Continuous operation” means 2 lamps operate when AC power is present and continue to operate during AC power failure. “Emergency operation”
means lamps do not operate when AC power is present, but 2 lamps operate from the DC battery pack only during AC power failure. “Semi-continuous” means 2
lamps operate when AC power is present and 1 lamp continues to operate during AC power failure.
➊ For fixtures with guard, substitute G for N before adding voltage suffix.
➋ Lamp included as standard.
➌ To order fixture with NEMA type 2 refractor, change final digit J5 in catalog number to J2.
➍ One hub, rigid or flexible mounting.

1190

Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

Mercmaster™ III Emergency Battery Pack

Enclosed and Gasketed. For Hazardous and Wet Locations
Simultaneous Exposure
Class I, Division 2, Class II, Division 1
Class I, Division 2, Group A, B, C, D
Class II, Division 1 and 2, Groups E, F, G
Class III

Lamp Hub Size
Watts (Inches)

Ceiling

Wall

90° Stanchion

25° Stanchion

Volts

Hz

with Globe ➊➋

Catalog Numbers
with Type V 12” Refractor
➊➋➌

with Enclosed
Reflector ➊➋➌

84

3/4

Semi-Continuous 120-277

50/60

KPAF84S2G4NBUL

KPAF84S2J5NBUL

KPAF84S2RNBUL

84

1

Semi-Continuous 120-277

50/60

KPAF84S3G4NBUL

KPAF84S3J5NBUL

KPAF84S3RNBUL

84

3/4

Semi-Continuous 120-277

50/60

KPDF84S2G4NBUL

KPDF84S2J5NBUL

KPDF84S2RNBUL

84

1

Semi-Continuous 120-277

50/60

KPDF84S3G4NBUL

KPDF84S3J5NBUL

KPDF84S3RNBUL

84

3/4

Semi-Continuous 120-277

50/60

KPCF84S2G4NBUL

KPCF84S2J5NBUL

KPCF84S2RNBUL

84

1

Semi-Continuous 120-277

50/60

KPCF84S3G4NBUL

KPCF84S3J5NBUL

KPCF84S3RNBUL

84

3/4

Semi-Continuous 120-277

50/60

KPWF84S2G4NBUL

KPWF84S2J5NBUL

KPWF84S2RNBUL

84

1

Semi-Continuous 120-277

50/60

KPWF84S3G4NBUL

KPWF84S3J5NBUL

KPWF84S3RNBUL

84

1-1/4 Semi-Continuous 120-277

50/60

KPRF84S4G4NBUL

KPRF84S4J5NBUL

KPRF84S4RNBUL

84

1-1/2 Semi-Continuous 120-277

50/60

KPRF84S5G4NBUL

KPRF84S5J5NBUL

KPRF84S5RNBUL

84

1-1/4 Semi-Continuous 120-277

50/60

KPSF84S4G4NBUL

KPSF84S4J5NBUL

KPSF84S4RNBUL

84

1-1/2 Semi-Continuous 120-277

50/60

KPSF84S5G4NBUL

KPSF84S5J5NBUL

KPSF84S5RNBUL

NOTE: “Continuous operation” means 2 lamps operate when AC power is present and continue to operate during AC power failure. “Emergency operation”
means lamps do not operate when AC power is present, but 2 lamps operate from the DC battery pack only during AC power failure. “Semi-continuous” means 2
lamps operate when AC power is present and 1 lamp continues to operate during AC power failure.
➊ For fixtures with guard, substitute G for N before adding voltage suffix.
➋ Lamp included as standard.
➌ To order fixture with NEMA type 2 refractor, change final digit J5 in catalog number to J2.
➍ One hub, rigid or flexible mounting.
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

1191

Lighting: Enclosed and Gasketed — Emergency

Pendant Cone

Mode of
Operation

Lighting

Pendant ➍

Wet Locations
NEMA 4X

Mercmaster™ III Emergency Battery Pack Mounting Hoods and Ballast Bodies
Enclosed and Gasketed. For Hazardous and Wet Locations
Simultaneous Exposure
Class I, Division 2, Class II, Division 1
Class I, Division 2, Group A, B, C, D
Class II, Division 1 and 2, Groups E, F, G
Class III

Wet Locations
NEMA 4X

Mounting Hoods
Description

Hub Size (Inches)

Catalog Number

Lighting

Pendant
One Hub, Rigid Mounting
One Hub, Flexible Mounting

3/4

KPA-75

1

KPA-100

3/4

KPAF-75

1

KPAF-100

3/4

KPCH-75

1

KPCH-100

3/4

KPC-75

1

KPC-100

3/4

KPWB-75

1

KPWB-100

1-1/4

KPS-125

1-1/2

KPS-150

1-1/4

KPST-125

1-1/2

KPST-150

Lighting: Enclosed and Gasketed — Emergency

Pendant Cone
One Hub,
Rigid Mounting

Ceiling
Five Hubs,
Four Close-Up Plugs

Wall
Five Hubs,
Four Close-Up Plugs

25° Stanchion
One Hub

90° Stanchion
One Hub

Ballast Bodies

1192

Lamp
Wattage

Mode of Operation

Voltage

Hz

Ballast Body
Catalog Number

26

Continuous

120-277

50/60

KPBC26FBU

26

Emergency

120-277

50/60

KPBE26FBU

26

Semi Continuous

120-277

50/60

KPBS26FBU

52

Continuous

120-277

50/60

KPBC52FBU

52

Emergency

120-277

50/60

KPBE52FBU

52

Semi Continuous

120-277

50/60

KPBS52FBU

64

Semi-Continuous

120-277

50/60

KPBS64FBU

84

Semi-Continuous

120-277

50/60

KPBS84FBU

Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

Mercmaster™ III Emergency Battery Pack Accessories
Enclosed and Gasketed. For Hazardous and Wet Locations
Simultaneous Exposure
Class I, Division 2, Class II, Division 1
Class I, Division 2, Group A, B, C, D
Class II, Division 1 and 2, Groups E, F, G
Class III

Item

Wet Locations
NEMA 4X

Description

Catalog Number

White Polyester Reflectors
For use with globe fixtures

mm

Standard Dome17.

18.70"

06

"

18.70"

17

CMR4-ST *

30° Angle

CMR4-AN

Lighting

117
.06 4337.0.066"
.3 "/
"

17

18.70"/
18.70" 18.70"
475.0 mm

Standard Dome

30°
Angle
7-11/16"
7-11/16"
"

.06

Prismatic Glass Globes

7-11/16"
11-5/16"11-5/16"

11-5/16"
11.31”11-5/16"
/287.3

Heat-resistant

Lighting: Enclosed and Gasketed — Emergency

7.69"
/195.3 mm
7-11/16"

VPGL-4HR

Clear

mm

6-1/4" 6-1/4"

6-1/4"
6.25”

/158.8
mm 7.69"
6-1/4" 7.69"

Closed Prismatic Glass
Refractors
7.69"
7.69" mm
7.69”/195.3

11.50" 11.50"
11.50"

11.50"

11.58”/294.1 mm

NEMA Type II

KPRF400-2

NEMA Type V

KPRF400-5

Heat- and impact-resistant glass lens

KPR-4HB

Globe Guard

KPGU400

Refractor Guard

KPBG12

Enclosed Reflector Guard

GHB7000-NG

12.05" 12.05"

12.05"
12.05”/306.1
12.05"

mm

7.69”/195.3
7.69"

mm

Enclosed Reflector Assembly
7.69" 7.69"
7.69"

11.50"

16.38"

11.50" 11.50"

11.50"
11.50”/292.1
mm

16.38"

16.38"
16.38"
16.38”/
416.1mm

Stainless Steel Guards

Globe

Refractor

Enclosed Reflector

Photocontrol
Factory-Installed †

Voltage Range

Mercmaster III Wall Mounting with
Photocontrol Factory Installed
Field-Installed

Suffix Designation

120 V, 50/60 Hz

H1

208 V, 50/60 Hz

H2

240 V, 50/60 Hz

H3

277 V, 50/60 Hz

H4

Max. Current

Voltage Range

Catalog Number

8.3 A

120 V, 50/60 Hz

PC120D2

3.5 A

208-277 V, 50/60 Hz

PC247D2

Photocontrol for Field Installation
* Consult factory if used with KPWB or KPST mounting hoods.
† Add to fixture catalog after voltage; i.e.: KPWF26C2G4NBULH1.
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

1193

Mercmaster™ III Emergency Battery Pack Accessories
Enclosed and Gasketed. For Hazardous and Wet Locations

Item

Description

Catalog Number

Three-Way Exit Sign
EXR400

Lighting

Epoxy enameled steel — 10” high red lettering
Mounts to fixture units in place of guard

Replacement Optic Gaskets
Silicone Rubber
KRF-GK

Lighting: Enclosed and Gasketed — Emergency

Globe, Refractor and 	
Enclosed Refractor Gasket
Replacement Lamp

PLC

PLT

Lamp Type

Lamp Base

Wattage

Catalog Number

PL-C

G24Q-1

13

PLC134

PL-T

G24q-4

26

PLT26

PL-T

G24q-4

32

PLT32

PL-T

G24q-4

42

PLT42

Replacement Socket

PLC

For 26 W (2 x 13 W) PLC Lamps

PLC13RS

For 26 W, 32 W and 42 W PLT Lamps listed above

PLT32RS

PLT
Retrofit Pendant Mounting Adapter
Permits use of Mercmaster III pendant hood with 3/4” hub on existing
V-51 mounting hood.

LPAD-1

Fuse Kit
2-amp time delay fuse

1194

F2

Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

EFDB™ Factory Sealed Push-To-Test Station
Explosionproof, Dust-Ignitionproof

Applications

Description

Dead-End

Feed-Thru

1 Circuit 	
Universal

EFDB150-U1-TEST

EFDCB150-U1-TEST

EFDB175-U1-TEST

EFDCB175-U1-TEST

EFDB110-U1-TEST

EFDCB110-U1-TEST

Single Gang *
Momentary Contact

Features

1/2
3/4
1

Replacement Parts for Push-to-Test Switch
Description

Catalog Number

Complete Cover Assy

EFKB-U1-TEST

Push Button Only

SPBBU1Q

Test Legend Plate

SNPTESTQ

12-24 x 1 (4) Screws

B

A
4.63”/
117.6 mm

5.41”/
137.4 mm

6.38”/
162.1 mm
9/32 Dia.
Hole

2.31"/
58.7 mm
3.00”/
76.2 mm

5/16 Dia. 	
(2) Mtg.
Holes

5.00”/
127 mm

C

EFDB Single Gang Push-To-Test Control Station
Dimensions in Inches/Millimeters
B

Hub Size
(Inches)

A

1/2 & 3/4

5.38/136.7

6.13/155.7

0.78/19.8

1

5.50/139.7

6.31/160.3

0.94/23.9

C

* Malleable iron body and aluminum cover. For aluminum body, add suffix -A.
For Class I, Group B, external seals must be installed at each conduit entrance.

Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

1195

Lighting: Enclosed and Gasketed — Emergency

•	 Eliminates need for adding sealing
fittings and compound at each conduit
entrance (Groups C and D).
•	 Heavy-duty, 10 ampere 600 V rated.
•	 Smooth, rounded integral bushing in
each EFDB hub protects conductor
insulation.
•	 Accurately tapped, tapered hubs for
tight, rigid joints and ground continuity.
•	 Stainless steel push button shaft
operators within stainless steel bushing
assures long, maintenance-free
operation.
•	 Push button contacts are silver
cadmium oxide which are “sealed”
in lower phenolic chamber isolated
from corrosive elements. Assures
positive contact and long, trouble-free
operation.
•	 Enclosed stainless steel helper spring
prevents accidental operation of push
button in severe vibration installations.
•	 Corrosion-resistant captive stainless
steel hex-head cap screws hold EFKB
cover to body.
•	 All EFDB front-operated push buttons
are supplied with lockout type guards
as standard. Hole in guard will accept
locks with up to 1/4” hasp. Permits
locking of push button to prevent
unauthorized operation.
•	 Clearly marked terminals with brass
screws assure quick, easy wiring.

Catalog Number

Hub Size
(Inches)

Lighting

•	 Push-to-test switch permits
interruption of AC power to fixture to
provide verification in an emergency
lighting system that battery packs and
lamps are functioning properly.

Mercmaster™ III Emergency Battery Pack Dimensions and Weights
Enclosed and Gasketed. For Hazardous and Wet Locations

Ceiling with Refractor
Enclosed Reflector and Guards

Pendant with Globe, Guard and Reflectors

Lighting

13.44"/
341.4 mm

13.44"/
341.4 mm
17.23"/
437.6 mm
11.21"/
284.7 mm
9.79"/
248.6 mm

11.82"/
300.2 mm

6.04" /
153.4 mm

11.65"/
295.9 mm

--1

7.0

6"

/4

33

.3

mm

10.35"/
262.9 mm

11.44"/
290.6 mm

12.38"/
314.5 mm

Dia

12.09"/
307.1 mm

10.38"/
263.7 mm

.

12.12"/
307.8 mm

18.70"/ 475.0 mm Dia.

16.38"/
416.1 mm

8.80"/
223.5 mm

12.25"/
311.2 mm Dia.

25° Stanchion

Wall
0.31"/
7.9 mm Dia

/
27" m
15. .9 m
7
8
3

Cone

17.00"/
431.8 mm
13.44"/
341.4 mm

5"/
9.2.0 mm "/
8
235 8.1   mm
.7
207

12 4.
0. 75
7 "/
m
m

4.06"/
103.1 mm

Lighting: Enclosed and Gasketed — Emergency

11.0"/
279.4 mm

10.25"/
260.4 mm
10.77"/
273.6 mm

90° Stanchion

/
07" m
12. .8 m
6
30

1.38"/
35.1 mm

13.08"/
332.2 mm
15.63"/
422.4 mm

12.12"/
307.8 mm

Mercmaster III – Emergency Ballast and Accessory Weights *
Ballast Housing (Wt. lbs/kg)
Lamp Watts

Continuous

SemiContinuous

Emergency

26

23.00/10.4

23.00/10.4

23.00/10.4

52

23.00/10.4

23.00/10.4

23.00/10.4

64

—

23.00/10.4

—

84

—

23.00/10.4

—

Mounting Hoods

Wt. (lbs/kg)

Refractor, Globe,
Reflector and Guards

Wt. (lbs/kg)

Pendant

2.25/1.0

Standard Dome

3.50/1.6

Pendant Cone

2.50/1.1

30° Angle

3.50/1.6

Ceiling

3.00/1.4

Glass Globe

7.00/3.2

Wall

4.00/1.8

Globe Guard

25° Stanchion

3.25/1.5

12” Glass Refractor

90° Stanchion

3.75/1.7

Refractor Guard
Enclosed Reflector
Enclosed Reflector Guard

3.00/1.4
12.00/5.4
4.50/2.0
11.00/5.0
2.00/0.9

* Weights are approximate.

1196

Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

Mercmaster™ III Emergency Battery Pack Photometric Data
Enclosed and Gasketed. For Hazardous and Wet Locations

Total Luminaire Efficiency = 58.3%
CIE Type – Semi-Direct
Plane

Spacing
Criteria
2.98

90-270

2.98

Diagonal

2.94

Coefficients of Utilization - Zonal Cavity Method
Effective Floor Cavity Reflectance 0.20
% Ceiling Rcc
% Walls Rw

Lumens
4.21
14.03
29.45
52.29
76.42
97.89
115.41
126.24
130.30
128.10
116.00
87.78

120-130
130-140
140-150
150-160
160-170
170-180

49.16
17.40
3.58
0.35
0.02
0.00

Total Luminaire Efficiency = 77.4%
CIE Type – Direct
Plane

Spacing
Criteria

0-180

1.68

90-270

1.68

Diagonal

1.82

Zone
0-10
10-20
20-30
30-40
40-50
50-60
60-70
70-80
80-90
90-100
100-110
110-120

Lumens
27.68
83.17
138.57
194.85
240.48
264.71
251.68
154.88
37.26
0.55
0.00
0.00

120-130
130-140
140-150
150-160
160-170
170-180

0.00
0.00
0.00
0.00
0.00
0.00

80
70
64
55
48
43
39
36
33
30
28
26
24

0
1
2
3
4
5
6
7
8
9
10

50
64
51
42
36
31
27
24
21
19
17
16

30
64
47
37
30
25
21
18
16
14
12
11

70
10
64
44
33
26
21
17
14
12
10
9
8

70
60
51
45
40
36
33
30
27
25
24
22

50
60
47
39
33
29
25
22
20
18
16
15

30
60
44
34
28
23
20
17
15
13
12
10

50
10
60
41
31
24
19
16
13
11
10
8
7

50
52
40
33
28
24
21
19
17
15
14
13

30
52
38
30
24
20
17
15
13
11
10
9

30
10
52
35
26
21
17
14
11
10
8
7
6

50
45
34
28
24
20
18
16
14
13
12
11

30
45
32
25
20
17
14
12
11
9
8
8

10
10
45
30
22
17
14
11
10
8
7
6
5

50
39
29
23
19
16
14
13
12
10
10
9

30
39
27
21
17
14
12
10
9
8
7
6

0
10
39
25
19
14
11
9
8
7
6
5
4

0
36
23
16
12
9
7
6
5
4
4
3

Zonal Lumen Summary
Zone
0-30
0-40
0-60
0-90

Lumens
47.69
99.98
274.29
646.24

% Lamp
2.6
5.6
15.2
35.9

% Fixture
4.5
9.5
26.2
61.6

Zone
90-120
90-130
90-150
90-180
0-180

Lumens
331.87
381.04
402.02
402.40
1048.64

% Lamp
18.4
21.2
22.3
22.4
58.3

% Fixture
31.6
36.3
36.3
38.4
100.0

REPORT NUMBER: KPBF26BU_ST
26 W (two 13 W PLT lamps) Fluorescent Fixture with Globe and Reflector
Coefficients of Utilization - Zonal Cavity Method
Effective Floor Cavity Reflectance 0.20
% Ceiling Rcc
% Walls Rw
0
1
2
3
4
5
6
7
8
9
10

80
70
92
83
74
66
60
55
50
46
43
40
37

50
92
78
67
57
50
44
39
35
31
29
26

30
92
74
60
50
42
36
31
27
24
22
20

70
10
92
71
55
44
36
30
26
22
19
17
15

70
90
81
72
64
58
53
49
45
41
39
36

50
90
77
65
56
49
43
38
34
31
28
26

30
90
73
59
49
41
35
31
27
24
22
19

50
10
90
70
55
44
36
30
25
22
19
17
15

50
86
73
62
53
46
41
36
33
30
27
25

30
86
70
57
48
40
34
30
26
24
21
19

30
10
86
68
53
43
35
30
25
22
19
17
15

50
82
70
59
51
45
39
35
32
29
26
24

30
82
68
55
46
39
34
29
26
23
21
19

10
10
82
65
52
42
35
29
25
22
19
17
15

50
79
67
57
49
43
38
34
31
28
25
23

30
79
65
54
45
38
33
29
25
23
20
19

0
10
79
63
51
41
34
29
25
21
19
17
15

0
77
62
49
39
32
27
23
20
17
15
13

Zonal Lumen Summary
Zone
0-30
0-40
0-60
0-90

Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

Lumens
249.42
444.27
949.47
1393.29

% Lamp
13.9
24.7
52.7
77.4

% Fixture
17.9
31.9
68.1
100.0

Zone
90-120
90-130
90-150
90-180
0-180

Lumens
0.55
0.55
0.55
0.55
1393.83

% Lamp
0.0
0.0
0.0
0.0
77.4

% Fixture
0.1
0.1
0.1
0.1
100.0

1197

Lighting: Enclosed and Gasketed — Emergency

Zone
0-10
10-20
20-30
30-40
40-50
50-60
60-70
70-80
80-90
90-100
100-110
110-120

Lighting

0-180

REPORT NUMBER: KPBF26BU_G
26 W (two 13 W PLT lamps) Fluorescent Fixture with Globe only

Mercmaster™ III Emergency Battery Pack Photometric Data
Enclosed and Gasketed. For Hazardous and Wet Locations

Total Luminaire Efficiency = 90.2%
CIE Type – Semi-Direct

Lighting: Enclosed and Gasketed — Emergency

Lighting

Plane

Spacing
Criteria

0-180

2.72

90-270

2.72

Diagonal

2.72

Zone
0-10
10-20
20-30
30-40
40-50
50-60
60-70
70-80
80-90
90-100
100-110
110-120

Lumens
23.61
79.09
165.61
289.36
418.89
535.78
628.00
682.79
696.63
676.63
612.00
481.82

120-130
130-140
140-150
150-160
160-170
170-180

304.45
133.76
39.22
5.66
0.24
0.00

Total Luminaire Efficiency = 72.8%
CIE Type – Direct
Plane

Spacing
Criteria

0-180

1.66

90-270

1.66

Diagonal

1.80

Zone
0-10
10-20
20-30
30-40
40-50
50-60
60-70
70-80
80-90
90-100
100-110
110-120

Lumens
88.11
264.99
444.26
624.25
769.77
853.68
821.26
573.91
212.45
4.66
0.00
0.00

120-130
130-140
140-150
150-160
160-170
170-180

0.00
0.00
0.00
0.00
0.00
0.00

1198

REPORT NUMBER: KPBF84BU_G
84 W (two 42 W PLT lamps) Fluorescent Fixture with Globe Only
Coefficients of Utilization - Zonal Cavity Method
Effective Floor Cavity Reflectance 0.20
% Ceiling Rcc
% Walls Rw
0
1
2
3
4
5
6
7
8
9
10

80
70
99
85
75
67
61
55
50
46
43
40
37

50
99
78
65
56
48
42
37
33
30
27
25

30
99
73
57
47
39
33
29
25
22
19
17

70
10
99
68
51
40
32
26
22
19
16
14
12

70
93
79
69
62
56
51
46
43
39
37
34

50
93
73
61
52
45
39
35
31
28
25
23

30
93
68
53
44
36
31
27
23
20
18
16

50
10
93
63
47
37
30
25
21
18
15
13
12

50
81
62
52
44
38
33
29
26
24
22
20

30
81
58
46
37
31
26
23
20
17
16
14

30
10
81
55
41
32
26
21
18
15
13
11
10

50
70
53
43
36
31
28
24
22
20
18
17

30
70
50
39
31
26
22
19
17
15
13
12

10
10
70
47
35
27
22
18
15
13
11
9
8

50
60
44
35
30
25
22
20
18
16
15
14

30
60
42
32
26
21
18
15
14
12
11
10

0
10
60
39
29
22
18
14
12
10
9
8
7

0
55
35
25
18
14
11
9
8
7
6
5

Zonal Lumen Summary
Zone
0-30
0-40
0-60
0-90

Lumens
268.3
557.66
1512.33
3519.72

% Lamp
4.2
8.7
23.6
55.0

% Fixture
4.6
9.7
26.2
61.0

Zone
90-120
90-130
90-150
90-180
0-180

Lumens
1770.44
2074.89
2247.86
2253.77
5773.48

% Lamp
27.7
32.4
35.1
35.2
90.2

% Fixture
30.7
35.9
35.9
39.0
100.0

REPORT NUMBER: KPBF84BU_ST
84 W (two 42 W PLT lamps) Fluorescent Fixture with Globe and Reflector
Coefficients of Utilization - Zonal Cavity Method
Effective Floor Cavity Reflectance 0.20
% Ceiling Rcc
% Walls Rw 70
0 87
1 77
2 69
3 62
4 56
5 51
6 47
7 43
8 40
9 37
10 35

80
50 30
87 87
73 69
61 55
53 46
46 38
40 33
36 28
32 25
29 22
26 20
24 18

10
87
65
50
40
33
27
23
20
17
15
14

70
85
75
67
60
54
49
45
42
38
36
34

70
50 30
85 85
71 67
60 55
51 45
45 38
39 32
35 28
31 25
28 22
26 20
24 18

10
85
64
50
40
32
27
23
20
17
15
14

50
81
68
57
49
43
38
34
30
27
25
23

50
30
81
65
53
44
37
31
27
24
21
19
17

10
81
62
49
39
32
27
23
20
17
15
14

50
77
65
55
47
41
36
32
29
26
24
22

30
30
77
62
51
42
36
31
27
24
21
19
17

10
77
60
47
38
31
26
23
20
17
15
14

50
74
62
52
45
39
35
31
28
25
23
22

10
30
74
60
49
41
35
30
26
23
21
19
17

10
74
58
46
37
31
26
22
19
17
15
14

0
0
73
57
45
36
29
24
21
18
15
14
12

Zonal Lumen Summary
Zone
0-30
0-40
0-60
0-90

Lumens
797.37
1421.62
3045.07
4652.69

% Lamp
12.5
22.2
47.6
72.7

% Fixture
17.1
30.5
65.4
99.9

Zone
Lumens
90-120
4.66
90-130
4.66
90-150
4.66
90-180
4.66
0-180 4657.35

% Lamp
0.1
0.1
0.1
0.1
72.8

% Fixture
0.1
0.1
0.1
0.1
100.0

Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

Mercmaster™ III Emergency Battery Pack Lumen Curves
Enclosed and Gasketed. For Hazardous and Wet Locations

BHD65U Lumen Curve
One Lamp PL-T 42 W In Emergency Mode

BHD65U Lumen Curve
One Lamp PL-T 32 W In Emergency Mode

400

300

Lighting

350
250
300
250
Lumens

Lumens

200

150

200

100
50

0

50
0
0

10

20

30

40

50

60

70

80

90

80

90

Discharge time (minutes)

0

10

20

30

40

50

60

70

80

90

Discharge time (minutes)

BHD65U Lumen Curve
Two Lamp PL-T 26 W In Emergency Mode
450
400
350

Lumens

300
250
200
150
100
50
0

0

10

20

30

40

50

60

70

Discharge time (minutes)

Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

1199

Lighting: Enclosed and Gasketed — Emergency

150
100

N2LS™ Series Emergency Luminaires
Enclosed and Gasketed

Non-Metallic Emergency Lighting Systems with Remote or Direct Mounted Lamps.
Class I, Division 2, Groups B, C, D
Class I, Zone 2, Group IIB + H2
NEMA 3R

Lighting: Enclosed and Gasketed — Emergency

Lighting

Applications
•	 Enclosed and gasketed, non-metallic emergency lighting
system suitable for use in areas where flammable gases or
vapors may become present due to abnormal, unusual or
accidental conditions defined by NEC as Class I, Division 2,
Groups B, C and D and Class I, Zone 2, Group II B + H2.
•	 Typical applications include manufacturing plants, refineries,
petrochemical and chemical plants, waste and sewerage
treatment facilities, food processing facilities, and other
industrial manufacturing or process facilities subject to wet or
corrosive conditions.
•	 Non-hazardous areas where dirt, dust or corrosion would
reduce life of ordinary emergency lighting systems.

Features
•	 Certified for use in Class I, Division 2, Groups B, C, D; Class I,
Zone 2, Group II B + H2 Hazardous Locations.
•	 Enclosures are Type 3R (raintight) rated and suited for operation
in highly corrosive and wet locations.
•	 The electronics consist of a solid-state charger, transfer circuit
and low voltage battery disconnect circuit.
•	 The test switch and AC “On” indicator light are mounted on the
system housing utilizing a neoprene “O-ring” gasket to seal out
moisture and liquids.
•	 Capacity is sufficient for the connection of 36 or 72 output
Watts (maximum).
•	 Housing provisions allow for the attachment of single or dual, 8
or 12 Watt halogen sealed beam heads (Wattage cannot exceed
unit capacity.)
•	 Provides 90 minutes of emergency operation.
•	 The solid-state charger maintains battery at full charge.
•	 Upon failure or 35% dip of utility voltage (AC), the DC
emergency lighting load is connected to the battery.
•	 During emergency operation, automatic battery protection from
deep discharge damage is provided by a low-voltage battery
disconnect (LVD) circuit.
•	 Upon restoration of normal power, the charger will begin a
recharge cycle. It will bring the battery to full capacity within
acceptable UL time standards.
•	 A pilot light indicates the presence of AC line voltage, and a test
switch is provided for checking transfer operation.
•	 A universal transformer allows operation on 120, 220, 240 or
277 VAC 50/60HZ. lines.
•	 Emergency power source is a sealed cell, lead acid,
maintenance-free battery suited for harsh temperature
environments of 32° to 104°F / 0° to 40°C.
•	 15 amp fuse provided as standard.
•	 Expected life is 10 years.
•	 Remote lamp head assemblies (one or two) are available for
mounting of lamp heads away from main power supply system.
•	 Time delay relay (15 min.) provided as standard; allows time for
HID lighting to reach desired illumination levels.

1200

Standard Materials
•	 Lighting system:
—Body: Compression molded, fiberglass reinforced polyester
(FRP)
— Gasket: continuous silicone gasket and FRP
— Mounting feet: fiberglass reinforced polyester
•	 Remote unit:
— Body: specially formulated fiberglass reinforced polyester
with low surface resistivity that will not hold a static charge
— Mounting feet: stainless steel
—	Screws (hold covers to bodies): stainless steel
— Gasket (between covers to bodies): neoprene
•	 Gaskets (under pilot light and push to test switch): neoprene
•	 Hubs: glass filled polyester with zinc plated steel insert
•	 Lamphead: Noryl® thermoplastic

Certifications and Compliances
•	 UL Standard: UL 924
•	 UL Listed: E175025
•	 NFPA 101 Life Safety Code

Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

N2LS™ Series Emergency Luminaire Technical Data
Enclosed and Gasketed

Non-Metallic Emergency Lighting Systems with Remote or Direct Mounted Lamps.
Class I, Division 2, Groups B, C, D
Class I, Zone 2, Group IIB + H2
NEMA 3R

Order using catalog numbering guide below or select catalog number from tables on following pages.
Catalog Numbering Guide For N2LS
N2LS

2

8

36

Lighting

Lamp Voltage:
6 - 6 Vdc
12 - 12 Vdc

Series:
N2LS - Emergency Lighting System

Wattage Capacity:
36 - 36 W
72 - 72 W

Thermal Performance — Operating Temperatures
Wire Supply

Ambient Temperature

“T” Number

140°F/60°C

Min. 32°F to max 104°F / 0°C to max 40°C

T6

“T” Numbers Represent the Maximum Lamp Temperature for Class I, Division 2 Locations
“T”
Number

T1

350

325

T2

T2A

T2B

T2C

T2D

T3

T3A

T3B

T3C

T4

T4A

T5

T6

Temp.
Range
(˚ºF)

664842

619662

574617

538572

502536

448500

421446

394419

358392

331356

322329

277320

250275

214248

187212

185

Temp
Range
(ºC)

351450

326350

301325

281300

261280

231260

216230

201215

181200

166180

161165

136160

121135

101120

86100

85

Wire Sizing For Remote Installations
For copper wire, maximum distance (feet) between power supply and remote unit to limit voltage drop to 5%.
For 6 Volt Units - Load in Watts

For 12 Volt Units - Load in Watts

Wire Size

8

16

24

32

8

16

24

32

16 AWG

26

13

6

3

52

26

12

6

14 AWG

42

21

10

5

84

42

20

10

12 AWG

66

33

16

8

132

66

32

16

10 AWG

106

53

26

13

212

106

52

26

  8 AWG

168

84

42

21

336

168

84

42

  6 AWG

270

135

67

33

540

270

134

66

Capacity of Standard N2LS Units

Up to two lamps may be direct mounted. The remainder must be remote mounted.
Number of lamps accommodated is dependent on whether 36 or 72 Watt unit is used.

Combination Number

1

2

3

4

6

7

8

9

10

11

12

13

14

15

Number of Lamps

1

1

2

2

3

3

4

4

5

5

6

7

8

9

Watts per Lamp

8

12

8

12

8

12

8

12

8

12

12

8

8

8

Total Wattage

8

12

16

24

24

36

32

48

40

60

72

56

64

72

Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

1201

Lighting: Enclosed and Gasketed — Emergency

Wattage Per Lamp
8-8W
12 - 12 W
N - No Direct Mounted Fixture
Number of Direct Mount Lamps:
0 - None
1 - One
2 - Two

6

N2LS™ Series Emergency Luminaires
Enclosed and Gasketed

Non-Metallic Emergency Lighting Systems with Remote or Direct Mounted Lamps.

Lighting: Enclosed and Gasketed — Emergency

Lighting

Class I, Division 2, Groups B, C, D
Class I, Zone 2, Group IIB + H2
NEMA 3R

Number
Watts
Lamp
Wattage
of Lamps Per Lamp Voltage (DC) Capacity
Emergency Lighting System With Two Direct Mount Lamps
2
8
6
36
2
8
12
36
2
8
6
72
2
8
12
72
2
12
6
36
2
12
12
36
2
12
6
72
2
12
12
72

Hub
Size

Input
Voltage *

Frequency

Weight
lbs/kg

Catalog
Number

3/4”
3/4”
3/4”
3/4”
3/4”
3/4”
3/4”
3/4”

120-277
120-277
120-277
120-277
120-277
120-277
120-277
120-277

50/60 Hz
50/60 Hz
50/60 Hz
50/60 Hz
50/60 Hz
50/60 Hz
50/60 Hz
50/60 Hz

19.50/8.8
19.50/8.8
19.50/8.8
19.50/8.8
19.50/8.8
19.50/8.8
19.50/8.8
19.50/8.8

N2LS28366
N2LS283612
N2LS28726
N2LS287212
N2LS212366
N2LS2123612
N2LS212726
N2LS2127212

36
36
72
72
36
36
72
72

3/4”
3/4”
3/4”
3/4”
3/4”
3/4”
3/4”
3/4”

120-277
120-277
120-277
120-277
120-277
120-277
120-277
120-277

50/60 Hz
50/60 Hz
50/60 Hz
50/60 Hz
50/60 Hz
50/60 Hz
50/60 Hz
50/60 Hz

18.50/8.4
18.50/8.4
18.50/8.4
18.50/8.4
18.50/8.4
18.50/8.4
18.50/8.4
18.50/8.4

N2LS18366
N2LS183612
N2LS18726
N2LS187212
N2LS112366
N2LS1123612
N2LS112726
N2LS1127212

36
36
72
72

3/4”
3/4”
3/4”
3/4”

120-277
120-277
120-277
120-277

50/60 Hz
50/60 Hz
50/60 Hz
50/60 Hz

17.50/7.9
17.50/7.9
17.50/7.9
17.50/7.9

N2LS0N366
N2LS0N3612
N2LS0N726
N2LS0N7212

Catalog
Number

Emergency Lighting System With One Direct Mount Lamp
1
8
6
1
8
12
1
8
6
1
8
12
1
12
6
1
12
12
1
12
6
1
12
12
Emergency Lighting System Without Direct Mount Lamps
—
—
6
—
—
12
—
—
6
—
—
12

Number
of Lamps

Watts
Lamp
Per Lamp Voltage (DC)

Hub
Size

Hub
Position *

Weight
lbs/kg

Remote Mount With One Lamp
8

6

3/4”

Dead End Hub on Right

4.00/1.8

N2RR186

1

8

12

3/4”

Dead End Hub on Right

4.00/1.8

N2RR1812

1

12

6

3/4”

Dead End Hub on Right

4.00/1.8

N2RR1126

1

12

12

3/4”

Dead End Hub on Right

4.00/1.8

N2RR11212

2

8

6

3/4”

Dead End Hub on Right

5.00/2.3

N2RR286

2

8

12

3/4”

Dead End Hub on Right

5.00/2.3

N2RR2812

2

12

6

3/4”

Dead End Hub on Right

5.00/2.3

N2RR2126

2

12

12

3/4”

Dead End Hub on Right

5.00/2.3

N2RR21212

1

Remote Mount With Two Lamps

* Input voltage is 120, 220, 240 and 277

1202

Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

N2LS™ Series Emergency Luminaire Dimensions
Enclosed and Gasketed

Non-Metallic Emergency Lighting Systems with Remote or Direct Mounted Lamps.

Dimensions (In/mm)
Direct Mount Fixture

Single Remote Mount Fixture

Dual Remote Mount Fixture
Lighting

1.75"/
44.5 mm

1.00"/
25.4 mm

.31"/
7.9 mm Dia.
(4) mtg holes

7.56"/ 192.0 mm
8.16"/ 207.7 mm

.31"/
7.9 mm Dia.
(4) mtg holes

1.62"/
41.1 mm

.31” dia.
(4) mtg holes

8.78"/ 223.0 mm
9.56"/ 242.8 mm

5.44”/
138.2 mm

Lighting: Enclosed and Gasketed — Emergency

11.63"/296.9 mm
14.80"/375.9 mm

.31"/
7.9 mm Dia.
(4) mtg holes

1.62"/
41.1 mm

2.81"/
71.4 mm
3.50"/
88.9 mm
4.06"/
103.1 mm

12.50"/
317.5 mm

2.81"/
71.4 mm
3.50"/
88.9 mm
4.06"/
103.1 mm

18.61"/
472.7 mm

1.00"/
25.4 mm

12.13"/ 308.1 mm
12.44"/ 316.0 mm
13.25"/ 336.6 mm
14.13"/ 385.9 mm

5.44”/
138.2 mm

1.44”/
35.6 mm
9.63”/
244.6 mm

9.63”/
244.6 mm

6.88”/
174.8 mm
1.38"/
35.1 mm
4.65"/
118.1 mm

1.38"/
35.1 mm
4.65"/
118.1 mm

Adjustment Angle Data For Remote Unit

100º

55º

26º

Top View

Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

Side View

1203

N2LS™ Series Emergency Luminaire Photometric Data
Enclosed and Gasketed

Non-Metallic Emergency Lighting Systems with Remote or Direct Mounted Lamps.

Lighting

Photometric Data

Horizontal Isofootcandle Distribution Curves for 8 Watts

Vertical Isofootcandle Distribution Curves for 8 Watts
20
20

20
20

Feet
Feet
Left
Left

Feet
Feet
Left
Left

10
10

10
10

Lamp
Axis

Lighting: Enclosed and Gasketed — Emergency

00

1

0.5

0.3

0.2

20
20
00

10
10

20
20

30
30

40
40

50
50
FEET FROM LAMP ( MEASURED ON AXIS )

60
60

70
70

80
80

0.2

0.1

00

10
10

20
20

30
40
50
30
40
50
FEET FROM LAMP ( MEASURED ON AXIS )

60
60

70
70

80

80

FEET FROM LAMP (MEASURED ON AXIS)

Vertical Isofootcandle Distribution Curves for 12 Watts

Horizontal Isofootcandle Distribution Curves for 12 Watts
20
20
Feet
Feet
Left
Left
10
10

20
20
Feet
Feet
Left

Left
10
10

1

00

00

20
20

0.5

40
40

0.3

0.2

60
60

FEET
FEETFROM
FROMLAMP
LAMP( MEASURED
(MEASUREDON
ONAXIS
AXIS))

1204

0.3

Feet
Feet
Right
Right

FEET FROM LAMP (MEASURED ON AXIS)

10
10
Feet
Feet
Left
Left
20
20

0.5

10
10

10
10
Feet
Feet
Right
Right
20
20

1

Lamp
Axis

00

0.1

0.1

80
80

1

0

100
100

10
10
Feet
Feet
Left
Left
20
20

00

20
20

0.5

40
40

0.3

0.2

60
60

0.1

80
80

100
100

FEET FROM LAMP ( MEASURED ON AXIS )

FEET FROM LAMP (MEASURED ON AXIS)

Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

Code•Master Jr.™ HID Factory Sealed Luminaires
Explosionproof, Dust-Ignitionproof

Integrally Ballasted. 50 W, 70 W, 100 W, 150 W HPS; 50 W, 70 W, 100 W, 175 W PSMH. 175 W MH V. Medium Base. For Use with Threaded Metal Conduit.
NEC:
Class I, Division 1 and 2, Groups B, C, D
Class II, Division 1 and 2, Groups E, F, G
Class III
Marine type electric fixtures, outside type
(salt water)

CSA: V
Class I, Division 1 and 2, Groups B, C, D
Class II, Division 1 and 2, Groups E, F, G
Class III
Type 4X
Exd IIB + H2

Applications
•	 For use in chemical and petrochemical plants, such as
manufacturers of plastics, paints and thinners; in refineries; 	
and in other areas where ignitable vapors, dust, moisture 	
and corrosive elements may be present.
•	 Suitable for outdoor saltwater locations and for other 	
wet locations.

Features

Lighting

Standard Materials
•	 Ballast bodies and guards: copperfree (4/10 of 1% max.)
	 aluminum
•	 Pendant mounting hoods: diecast copperfree (4/10 of 1% max.)
aluminum
•	 Ceiling, bracket and stanchion mounting hoods: sand cast  
copperfree (4/10 of 1% max.) aluminum
•	 Reflectors: fiberglass reinforced polyester

Standard Finishes
•	 Ballast bodies, guards and mounting hoods: epoxy powder 	
coat finish, electrostatically applied for complete, uniform
corrosion protection

Options
•	 Fuses: order fuses for field installation by catalog number, see
Ballast and Fuse Kit Data.
•	 “Hot Restrike” – add suffix -R. “Smart Starter” – add suffix -S.
Emergency Options available for 50 W through 150 W HPS only.
•	 For CEC Exd IIB + H2 rating, add suffix -Z V.
•	 For safety chain, add suffix -SC.

Certifications and Compliances
•	
•	
•	
•	

UL Standard: UL 1598, UL 844
UL Listed: E10444
CSA Standard: C22.2 No. 250, C22. 2No. 137
CSA Certified: 025428

Related Products
•	 For sealing fittings, see the Fittings Section.

V CSA Certification only.
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

1205

Lighting: Explosionproof — Area — HID

•	 Fixtures operate safely in high ambient temperatures.
•	 Arrangement of heat-producing components results in 	
efficient heat dissipation for cooler fixture operation.
•	 Patented “wireless” design. Threading of fixture unit 	
onto mounting hood makes electrical connection. Only 	
wiring required is attaching two wires to connection block 	
in mounting hood.
•	 Connection block is easily wired: (a) loosen two screws, (b)
make wire connections, and (c) re-position connection block.
•	 Safe, easy servicing without disconnecting any wiring.
“Wireless” fixture unit threads off mounting hood for convenient
servicing or for immediate replacement with a “stand-by” unit.
•	 Acme double-lead threads speed installation and fixture
removal from mounting hood – only half as many turns are
required as for single-lead threads. The threads do not stick or
gall, eliminating problems often encountered with single-lead
threads during fixture unit removal.
•	 All threaded joints are flame-tight.
•	 Integrally ballasted HID lighting fixtures; separate ballasts 	
not required.
•	 Factory sealed. External seals not required for Groups C and D.
•	 Fixtures for use in NEC Group B locations furnished complete
with UL required sealing fitting. Not required for CEC approval.
•	 Strategic location of lamp socket, in combination with interior
prism design of the glass globe, provides optimum light
distribution and control.
•	 Heat and impact-resistant globes have smooth 	
dust-resistant exterior.
•	 Superior corrosion resistance, with epoxy powder coat finish.
•	 Shock-absorbing medium-base socket mounts prolong 	
lamp life.
•	 Porcelain socket with nickel-plated phosphor bronze 	
screw shell. 	
Assures long trouble-free operation in high ambient areas.
•	 Choice of mountings: pendant, ceiling, bracket and stanchion.
•	 Fiberglass-reinforced polyester reflectors, in standard dome,
or 30° angle styles, are ideal in installations where luminaire is
subject to exceptionally severe corrosive atmospheres.
•	 Optional guards protect globes from damage. Secured to
fixture with three stainless steel screws.
•	 Variety of light sources: high pressure sodium, pulse start metal
halide and metal halide. HPS is excellent where long lamp life
is required. HPS provides high lumens per watt and is less
expensive to operate. PSMH and MH are desirable where
colors in illuminated areas must be close to natural.
•	 A wide range of ballasts and voltages are available for both
domestic and export applications.
•	 Ballasts operate at low temperatures – PSMH/MH: -20 °F/-29 °C;
HPS: -40 °F/-40 °C.
•	 50 W through 150 W high pressure sodium ballasts are high
reactance, high power factor type.

Code•Master Jr.™ HID Factory Sealed Luminaires
Explosionproof, Dust-Ignitionproof

Integrally Ballasted. 50 W, 70 W, 100 W, 150 W HPS; 50 W, 70 W, 100 W, 175 W PSMH. 175 W MH V. Medium Base. For Use with Threaded Metal Conduit.
NEC:
Class I, Division 1 and 2, Groups B, C, D
Class II, Division 1 and 2, Groups E, F, G
Class III
Marine type electric fixtures, outside type
(salt water)

CSA: V
Class I, Division 1 and 2, Groups B, C, D
Class II, Division 1 and 2, Groups E, F, G
Class III
Type 4X
Exd IIB + H2

104 °F/40˚ °C ➊
Lamp
Watts

Ambient
Temp. “T”
Numbers

Ballast
Type †

Supply
Wire Temp
°F/°C

131 °F/55 ˚°C ➊

149 °F/65 °C ➊

104 °F/40 ˚°C ➋

Ambient
Temp. “T”
Numbers

Supply
Wire Temp
°F/°C

Ambient
Temp. “T”
Numbers

Supply
Wire Temp
°F/°C

Ambient
Temp. “T”
Numbers

Supply
Wire Temp
°F/°C

High Pressure Sodium — Medium Base Lamps
50

MT, TT

T6

167/75

T5

167/75

T4A

167/75

T4

167/75

70

MT, TT, 480 V

T5

167/75

T4A

167/75

T4A

167/75

T4

194/90

100

MT, TT, 480 V

T4A

167/75

T4

194/90

—

T3B

194/90

150

MT, TT, 480 V

T3C

167/75

—

—

—

T6

167/75

T5

167/75

T4A

194/90

T3C

194/90

194/90

T3C

194/90

Lighting

Pulse Start Metal Halide — Medium Base Lamps
50

MT, TT

70

MT, TT, 480 V

T5

167/75

T4A

167/75

T4A

100

MT, TT, 480 V

T4A

194/90

T4A

194/90

—

175

MT, TT, 480 V

T3B

194/90

—

—

—

T3B

185/85

—

—

—

Metal Halide — Medium Base Lamps V

Lighting: Explosionproof — Area — HID

175

MT, TT, 480 V

“T” Numbers Represent the Maximum Surface Temperature for Class I, Division 1 Locations and
Maximum Surface Temperature Under Dust Blanket for Class II, Division 1 Locations.
“T”
Number

T1

350

325

T2

T2A

T2B

T2C

T2D

T3

T3A

T3B

T3C

T4

T4A

T5

T6

Temp.
Range
(°F)

664842

619662

574617

538572

502536

448500

421446

394419

358392

331356

322329

277320

250275

214248

187212

185

Temp.
Range
(°C)

351450

326350

301325

281300

261280

231260

216230

201215

181200

166180

161165

136160

121135

101120

86100

85

Fixture and Accessory Weights lbs/kgs
Fixture Size

Fixture Weight

Reflector Weight

Guard Weight

35 W thru 175 W

28-32/12.70-14.51

3/1.36

1/0.45

Pendant

Ceiling

Bracket

Stanchion

2/.91

4/1.81

6/2.72

2/0.91

Mounting Hood Weights lbs/kgs

NOTE: The maximum operating temperature of the fixture must not exceed the ignition temperature of the gas, vapor or dust to be encountered per the National
Electrical Code and the Canadian Electrical Code.
† MT is Multi-Tap for 120/208/240/277 V, TT is Tri-Tap for 120/277/347 V.
➊ Class I, Division 1 Locations.
➋ Class II, Division 1 Locations.
V CSA Certification only.

1206

Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

Code•Master Jr.™ HID Factory Sealed Luminaires
Explosionproof, Dust-Ignitionproof

Integrally Ballasted. 50 W, 70 W, 100 W, 150 W HPS; 50 W, 70 W, 100 W, 175 W PSMH. 175 W MH V. Medium Base. For Use with Threaded Metal Conduit.
NEC:
Class I, Division 1 and 2, Groups B, C, D
Class II, Division 1 and 2, Groups E, F, G
Class III
Marine type electric fixtures, outside type
(salt water)

Type
Mounting

Lamp
Watts

ANSI Lamp Type ➎
HPS

Catalog Number➌ ➋

PSMH

Hub Size
(Inches)

HPS➋ ➊

PSMH

M110

3/4

CJLPB5075 ➌

CJHPB5075 ➌

M98

3/4

CJLPB7075 ➍

CJHPB7075 ➍

M90

3/4

CJLPB1075 ➍

CJHPB1075 ➍

—

3/4

CJLPB1575 ➍

—

M152

3/4

—

CJPPB1775 ➍

M110

1-1/2

CJLSB50150 ➌

CJHSB50150 ➌

M98

1-1/2

CJLSB70150 ➍

CJHSB70150 ➍

M90

1-1/2

CJLSB10150 ➍

CJHSB10150 ➍

—

1-1/2

CJLSB15150 ➍

—

M152

1-1/2

—

CJPSB17150 ➍

Pendant - One Hub, Rigid or Flexible Mounting
S68

70

S62

100

S54

150

S55

175

—

Lighting

50

25˚ Stanchion - One Hub
50

100
150
175

S62
S54
S55
—

Mounting Hoods
Type
Mounting

Hub Size
(Inches)

Catalog
Number

Pendant
One Hub

3/4

CAP-75B

One Hub

1-1/2

CAS-150B

25˚ Stanchion

➊ Add suffix -SR (after adding voltage suffix) for “Smart Hot Strike” emergency option, -R for “Hot Restrike” and -S for “Smart Starter” options.
➋ To order fixture with guard, add suffix -G (before adding voltage suffix).
➌ Add voltage -MT for 120/208/240/277 V. For 480 V, contact your sales representative.
➍ Add voltage suffix -MT for 120/208/240/277 V, or -48 for 480 V. Contact your sales representative for available 50 Hz ballasts.
➎ Refer to lamp manufacturer’s data regarding lamp burning position restrictions.
➏ 35 W fixtures have 120 V ballast; add suffix -12
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

1207

Lighting: Explosionproof — Area — HID

70

S68

Code•Master Jr.™ HID Factory Sealed Luminaires
Explosionproof, Dust-Ignitionproof

Integrally Ballasted. 50 W, 70 W, 100 W, 150 W HPS; 50 W, 70 W, 100 W, 175 W PSMH. 175 W MH V. Medium Base. For Use with Threaded Metal Conduit.
NEC:
Class I, Division 1 and 2, Groups C, D
Class II, Division 1 and 2, Groups E, F, G
Class III
Marine type electric fixtures, outside type
(salt water)

CSA: V
Class I, Division 1 and 2, Groups B, C, D
Class II, Division 1 and 2, Groups E, F, G
Class III
Type 4X
Exd IIB + H2

ANSI Lamp Type ➏
Lamp
Watts
HPS
PSMH/MH
Pendant — One Hub, Rigid or Flexible Mounting

Hub Size ➐
(Inches)
3/4

50

S68

M110
1
3/4

70

S62

M98
1
3/4

Lighting

100

S54

M90
1
3/4

150

S55

—

Lighting: Explosionproof — Area — HID

1
3/4
175

—

M152
1

Catalog Number ➋
HPS ➊

50

S68

M110
1
3/4

70

S62

M98
1
3/4

100

S54

M90
1
3/4

150

S55

—
1
3/4

175

—

M152
1

MH

CJLP5075MT ➌
CJLP5075TTCN V ➌
CJLP5010MT ➌
CJLP5010TTCN V ➌
CJLP7075MT ➍
CJLP7075TTCN V➎
CJLP7010MT ➍
CJLP7010TTCN V➎
CJLP1075MT ➍
CJLP1075TTCN V➎
CJLP1010MT ➍
CJLP1010TTCN V➍
CJLP1575MT ➍
CJLP1575TTCN V➎
CJLP1510MT ➍
CJLP1510TTCN V➍
—
—
—
—

—
CJHP5075MT ➌
—
CJHP5075TTCN V ➌
—
CJHP5010MT ➌
—
CJHP5010TTCN V ➌
—
CJHP7075MT ➍
—
CJHP7075TTCN V➎
—
CJHP7010MT ➍
—
CJHP7010TTCN V➎
—
CJHP1075MT ➍
—
CJHP1075TTCN V➎
—
CJHP1010MT ➍
—
CJHP1010TTCN V➎
—
—
—
—
—
—
—
—
CJPP1775MT ➍
CJHP1775MTCN V ➍
CJPP1775TTCN V➎ CJHP1775TTCN V➎
CJPP1710MT ➍
CJHP1710MTCN V➍
CJPP1710TTCN V➎ CJHP1710TTCN V➎

CJLC5075MT ➌
CJLC5075TTCN V➌
CJLC5010MT ➌
CJLC5010TTCN V➌
CJLC7075MT ➍
CJLC7075TTCN V➎
CJLC7010MT ➍
CJLC7010TTCN V➎
CJLC1075MT ➍
CJLC1075TTCN V➎
CJLC1010MT ➍
CJLC1010TTCN V➎
CJLC1575MT ➍
CJLC1575TTCN V➎
CJLC1510MT ➍
CJLC1510TTCN V➎
—
—
—
—

—
CJHC5075MT ➌
—
CJHC5075TTCN V➌
—
CJHC5010MT ➌
—
CJHC5010TTCN V➌
—
CJHC7075MT ➍
—
CJHC7075TTCN V➎
—
CJHC7010MT ➍
—
CJHC7010TTCN V➎
—
CJHC1075MT ➍
—
CJHC1075TTCN V➎
—
CJHC1010MT ➍
—
CJHC1010TTCN V➎
—
—
—
—
—
—
—
—
CJPC1775MT ➍
CJHC1775MTCN V➍
CJPC1775TTCN V➎ CJHC1775TTCN V➎
CJPC1710MT ➍
CJHC1710MTCN V➍
CJPC1710TTCN V➎ CJHC1710TTCN V➎

Ceiling — Four Hubs, Three Close-Up Plugs
3/4

PSMH

➊ Add suffix -R for “Hot Restrike” and -S for “Smart Starter” options.
➋ To order fixture with guard, add suffix -G before adding voltage suffix.
➌ For 480 V, contact your sales representative.
➍ Change voltage suffix -MT to -48 for 480 V.
➎ Change voltage suffix -TT (120/277/347 V) to -MT for 120/208/240/277 V, -C2 for 208 V, -C3 for 240 V, -C6 for 480 V, or -C7 for 600 V, V
➏ Refer to lamp manufacturer’s data regarding lamp burning position restrictions.
➐ Fixtures with 1” hubs listed for Class I, Group D, and Class II, Groups E, F, G only.
V CSA Certification only.
 Shaded area indicates items suitable for Class I, Division 1, Group B. V

1208

Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

Code•Master Jr.™ HID Factory Sealed Luminaires
Explosionproof, Dust-Ignitionproof

Integrally Ballasted. 50 W, 70 W, 100 W, 150 W HPS; 50 W, 70 W, 100 W, 175 W PSMH. 175 W MH V. Medium Base. For Use with Threaded Metal Conduit.
NEC:
Class I, Division 1 and 2, Groups C, D
Class II, Division 1 and 2, Groups E, F, G
Class III
Marine type electric fixtures, outside type
(salt water)

CSA: V
Class I, Division 1 and 2, Groups B, C, D
Class II, Division 1 and 2, Groups E, F, G
Class III
Type 4X
Exd IIB + H2

Lamp ANSI Lamp Type ➏
Watts HPS PSMH/MH
Bracket — Four Hubs, Three Close-Up Plugs

Hub Size ➐
(Inches)
3/4

50

S68

M110
1
3/4

70

S62

M98
1
3/4

100

S54

M90

3/4
150

S55

—
1

175

—

M152
1

25˚ Stanchion — One Hub
50

S68

M110

70

S62

M98

100

S54

M90

150

S55

—

175

—

M152

1-1/4 or 1-1/2 CJLS50150MT ➌
➑
CJLS50150TTCN V➌
1-1/4 or 1-1/2 CJLS70150MT ➍
➑
CJLS70150TTCN V➍
1-1/4 or 1-1/2 CJLS10150MT ➍
➑
CJLS10150TTCN V➍
1-1/4 or 1-1/2 CJLS15150MT ➍
➑
CJLS15150TTCN V➍
—
1-1/4 or 1-1/2
➑
—

CJHB5075MT ➌
CJHB5075TTCN V➌
CJHB5010MT ➌
CJHB5010TTCN V➌
CJHB7075MT ➍
CJHB7075TTCN V➎
CJHB7010MT ➍
CJHB7010TTCN V➎
CJHB1075MT ➍
CJHB1075TTCN V➎
CJHB1010MT ➍
CJHB1010TTCN V➎
—
—
—
—
CJPB1775MT ➍
CJPB1775TTCN V➎
CJPB1710MT ➍
CJPB1710TTCN V➎

MH
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
CJHB1775MTCN V➍
CJHB1775TTCN V➎
CJHB1710MTCN V➍
CJHB1710TTCN V➎

—
CJHS50150MT ➌
—
CJHS50150TTCN V➌
—
CJHS70150MT ➌
—
CJHS70150TTCN V➌
—
CJHS10150MT ➌
—
CJHS10150TTCN V➌
—
—
—
—
CJPS17150MT
CJHS17150MTCN V
CJPS17150TTCN V
CJHS17150TTCN V

➊ Add suffix -R for “Hot Restrike” and -S for “Smart Starter” options.
➋ To order fixture with guard, add suffix -G before adding voltage suffix.
➌ For 480 V, contact your sales representative.
➍ Change voltage suffix -MT to -48 for 480 V.
➎ Change voltage suffix -TT (120/277/347 V) to -MT for 120/208/240/277 V, -C2 for 208 V, -C3 for 240 V, -C6 for 480 V, or -C7 for 600 V, V
➏ Refer to lamp manufacturer’s data regarding lamp burning position restrictions.
➐ Fixtures with 1” hubs listed for Class I, Group D, and Class II, Groups E, F, G only.
➑ 1-1/2" tapped hub furnished with 1-1/2" to 1-1/4" reducer.
V CSA Certification only.
 Shaded area indicates items suitable for Class I, Division 1, Group B. V
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

1209

Lighting: Explosionproof — Area — HID

3/4

CJLB5075MT ➌
CJLB5075TTCN V➌
CJLB5010MT ➌
CJLB5010TTCN V➌
CJLB7075MT ➍
CJLB7075TTCN V➎
CJLB7010MT ➍
CJLB7010TTCN V➎
CJLB1075MT ➍
CJLB1075TTCN V➎
CJLB1010MT ➍
CJLB1010TTCN V➎
CJLB1575MT ➍
CJLB1575TTCN V➎
CJLB1510MT ➍
CJLB1510TTCN V➎
—
—
—
—

Catalog Number ➋
PSMH

Lighting

1

HPS ➊

Code•Master Jr.™ HID Factory Sealed Luminaire Mounting Hoods and Fixture Units
Explosionproof, Dust-Ignitionproof

Integrally Ballasted. 50 W, 70 W, 100 W, 150 W HPS; 50 W, 70 W, 100 W, 175 W PSMH. 175 W MH V. Medium Base. For Use with Threaded Metal Conduit.
NEC:
Class I, Division 1 and 2, Groups B,C, D
Class II, Division 1 and 2, Groups E, F, G
Class III
Marine type electric fixtures, outside type
(salt water)

CSA: V
Class I, Division 1 and 2, Groups B, C, D
Class II, Division 1 and 2, Groups E, F, G
Class III
Type 4X
Exd IIB + H2

Mounting Hoods
Hub Size (Inches)

Catalog Number

Pendant — One Hub
3/4

CAP-75

1➋

CAP-100

Ceiling — Four Hubs, Three Close-Up Plugs
3/4

CAC-75

1➋

CAC-100

3/4

CALB-75

1➋

CALB-100

Lighting

Bracket — Four Hubs, Three Close-Up Plugs

25˚ Stanchion — One Hub
CAS-150

Lighting: Explosionproof — Area — HID

1-1/4 or 1-1/2 ➊

Mounting Adapter with Connection Block
Permits use of existing A-51 mounting hoods (AAC Ceiling
or AALB Bracket) with the new Code•Master 2 Fixture Unit.
After removing existing fixture unit and adapter, screw in
the new CMAD-1 Adapter. Then thread new fixture unit into
the CMAD-1.

CMAD-1

Fixture Units
Ballast body with globe. Indicate voltage desired by adding voltage suffix to fixture unit catalog number listed below.
Type

Lamp
Watts
50

High Pressure Sodium ➌
High Power Factor
(Min. P.F. 90%)

Pulse Start Metal Halide
Constant Wattage
(Min. P.F. 90%)
Metal Halide V
Constant Wattage
(Min. P.F. 90%)

Fixture Unit
Number
CJB50L-

120/208/240/277
MT

Add Voltage Suffixes
120/277/347 V➍
TTCN

480 V
—

70

CJB70L-

MT

TTCN

48

100

CJB100L-

MT

TTCN

48

150

CJB150L-

MT

TTCN

48

50

CJB50H-

MT

TTCN

—

70

CJB70H-

MT

TTCN

48

100

CJB100H-

MT

TTCN

48

175

CJB175P-

MT

TTCN

48

175

CJB175H-

MT

TT

C6

➊ 1-1/2” Tapped hub furnished with 1-1/2” to 1-1/4” reducer.
➋ Mounting Hoods with 1” hub listed for Class I, Group D; Class II, Groups E,F,G; and Class III only.
➌ Add suffix -R for “Hot Restrike” and -S for “Smart Starter” options.
➍ Change voltage suffix -TTCN to -MTCN for 120/208/240/277 V, -C2 for 208 V, -C3 for 240 V, -C6 for 480 V, or -C7 for 600 V, V
V CSA Certification only.
 Shaded area indicates items suitable for Class I, Division 1, Group B.

1210

Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

Code•Master Jr.™ HID Factory Sealed Luminaire Accessories
Explosionproof, Dust-Ignitionproof

Integrally Ballasted. 50 W, 70 W, 100 W, 150 W HPS; 50 W, 70 W, 100 W, 175 W PSMH. 175 W MH V. Medium Base. For Use with Threaded Metal Conduit.

Description

Catalog Number

Polyester Reflectors
Furnished with stainless steel screws

Standard Dome

Standard Dome

KR2-ST

30° Angle

KR2-AN

Epoxy enameled steel — 6”-high red lettering

CJEXRN

30° Angle

Three-Way Exit Sign
Mounts to Code•Master Jr. fixture units in place of guard.
Lighting

Single Sided Exit Sign
Epoxy enameled steel — 6”-high red lettering

AEXR-15R

Mounts to Code•Master Jr. fixture units in place of guard.

*Contact your sales representative regarding hazardous location suitability.

CJGL-175

Aluminum Guards — 50 W through 175 W
CJGU-15

Replacement Sockets — 50 W through 175 W

Connection Block — 50 W through 175 W

Medium base sockets

CJMS-175

For all Code•Master fixtures

VPT-7

HPS Hot Restrike
Restrikes HPS lamp immediately when power is restored after a momentary power interruption.
Optional for fixture watts of 50, 70, 100 or 150 (HPS only)

Add suffix -R

Smart Starter
Smart Starter is for HPS fixtures only. Incorporates a 1-1/2-minute timer and performs as a conventional starter to normally start lamp.
Removes itself from circuit if lamp burns out or is removed from socket. Eliminates starter failures caused by prolonged operation with
cycling or failing lamps and simplifies finding their location which reduces maintenance and repair costs.
Optional for all HPS and PSMH fixtures.
Add suffix -S
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

1211

Lighting: Explosionproof — Area — HID

Prismatic Glass Globe and Ring Assembly — 50 W through 175 W

Code•Master Jr.™ HID Factory Sealed Luminaire Ballast and Fuse Kit Data
Explosionproof, Dust-Ignitionproof

Integrally Ballasted. 50 W, 70 W, 100 W, 150 W HPS; 50 W, 70 W, 100 W, 175 W PSMH. 175 W MH V. Medium Base. For Use with Threaded Metal Conduit.
NEC:
Class I, Division 1 and 2, Groups B, C, D
Class II, Division 1 and 2, Groups E, F, G
Class III
Marine type electric fixtures, outside type
(salt water)

Volts

Ballast Amps
High Pressure Sodium
Pulse Start Metal Halide
HX-H.P.F. ➊
HX-H.P.F. ➊ — Super CWA ➋
Start
Operating
Start
Operating

HPS

PSMH

MH V

120

0.58

0.58

0.87

0.60

1

CF-5

CF-3

—

208

0.35

0.33

0.51

0.40

2

CF-3

CF-3

—

240

0.31

0.29

0.47

0.35

2

CF-3

CF-2

—

277

0.25

0.25

0.32

0.32

1

CF-2

CF-2

—

347 V

—

—

—

—

—

—

—

—

Lamp
Watts

Lighting

50

Lighting: Explosionproof — Area — HID

70

100

150

175

CSA: V
Class I, Division 1 and 2, Groups B, C, D
Class II, Division 1 and 2, Groups E, F, G
Class III
Type 4X
Exd IIB + H2

Fuse Kit Catalog Number
Fuse
Quantity
Required

480

—

—

—

—

—

—

—

—

120

0.90

0.82

0.80

0.85

1

CF-5

CF-5

—

208

0.50

0.48

0.50

0.52

2

CF-3

CF-3

—

240

0.44

0.41

0.43

0.44

2

CF-3

CF-3

—

277

0.35

0.36

0.39

0.39

1

CF-2

CF-2

—

347 V

0.30

0.30

0.20

0.28

1

CF-2

CF-2

—

480

0.21

0.21

0.26

0.23

2

CF-2

CF-2

—

120

1.30

1.15

1.20

1.15

1

CF-8

CF-8

—

208

0.76

0.67

0.70

0.70

2

CF-5

CF-5

—

240

0.66

0.58

0.61

0.58

2

CF-5

CF-3

—

277

0.60

0.50

0.55

0.50

1

CF-3

CF-3

—

347 V

0.45

0.30

0.40

0.40

1

CF-2

CF-2

—

480

0.33

0.31

0.30

0.35

2

CF-3

CF-2

—

120

2.00

1.66

—

—

1

CF-10

—

—

208

1.16

0.96

—

—

2

CF-5

—

—

240

1.00

0.83

0.85

0.80

2

CF-5

CF-5

—

277

1.00

0.83

—

—

1

CF-5

—

—
—

347 V

0.52

0.56

0.55

0.65

1

CF-3

—

480

0.88

0.75

—

—

2

CF-5

—

—

120

1.30

1.80

0.90

1.78

1

—

CF-5

CF-5

208

0.75

1.04

0.50

1.08

2

—

CF-3

CF-3

240

0.65

0.90

0.35

0.89

2

—

CF-3

CF-3

277

0.55

0.80

0.30

0.76

1

—

CF-2

CF-2

347 V

0.27

0.65

0.25

0.65

1

—

CF-2

CF-2

480

0.35

0.45

0.25

0.50

2

—

CF-2

CF-2

Fuse Kit includes fuse, fuse holder and necessary hardware for field installation. Mounts easily in ballast body with one screw. Order one fuse for 120 V and 277
V, and 2 fuses for 208, 240 and 480 V. CF-2 = 2 Amp; CF-3 = 3 Amp; CF-5 = 5 Amp; CF-8 = 8 Amp; CF-10 = 10 Amp
➊ 35 W through 150 W HPS and 50 W through 100 W PSMH have H.P.F. High Reactance ballasts.
➋ 175 W PSMH 480 volts has CWA ballast. Multi-tap has Super CWA ballast.
V CSA Certification only.

1212

Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

Code•Master Jr.™ HID Factory Sealed Luminaire Dimensions
Explosionproof, Dust-Ignitionproof

Integrally Ballasted. 50 W, 70 W, 100 W, 150 W HPS; 50 W, 70 W, 100 W, 175 W PSMH. 175 W MH V. Medium Base. For Use with Threaded Metal Conduit.

Pendant

Ceiling

Bracket
0.41"/
10.4 mm Dia.
2.46"/
2.28"/
62.5 mm 57.9 mm

4.25"/
108.0 mm

4.58"/
116.3 mm Dia.
3.75"/95.3 mm

4.92"/
125.0 mm Sq.

4.00"/
101.6 mm

4.50"/
114.3 mm

17.22"/
437.4 mm
4.00"/
101.6 mm

7.40"/
188.0 mm

17.87"/
453.9 mm

1.23"/
31.2 mm
3.46"/
87.9 mm

3.92"/
99.6 mm

5.92"/
150.4 mm

1.79"/
45.5 mm
11.5"/
292.1 mm
13.75"/
349.3 mm

14.12"/
358.6 mm

Lighting

7.40"/
188.0 mm

17.47"/
443.7 mm
18.12"/
460.2 mm

7.40"/
188.0 mm

8.00"/
203.2 mm

25˚ Stanchion

16.00"/
406.4 mm

Exit Signs

9.5"/
241.3 mm
6.10"/
154.9 mm

Reflectors
8.00"/
203.2 mm

6.88"/
174.8 mm

2.75"/
69.9 mm
11.75"/298.5 mm

4.5"/
60.5 mm Dia.

2.38"/
60.5 mm Dia.

16.25"/
412.8 mm

Lighting: Explosionproof — Area — HID

14.12"/
358.6 mm

15.62"/
396.7 mm

8.50"/
215.9 mm

14.9"/
378.5 mm

10.17"/
258.3 mm

8.00"/
203.2 mm

1.5 - 11 NPT

AEXR-15R

30° Angle
8.00"/
203.2 mm
6.00"/
152.4 mm

16.88"/
428.8 mm

16.00"/
406.4 mm

9.25"/
235.0 mm

12.00"/
304.8 mm

16.9"/
429.3 mm

CJEXRN

Standard Dome

16.25"/
412.8 mm

Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

1213

Code•Master Jr.™ HID Factory Sealed Luminaire HPS Photometric Data
Explosionproof, Dust-Ignitionproof

Integrally Ballasted. 50 W, 70 W, 100 W, 150 W HPS; 50 W, 70 W, 100 W, 175 W PSMH. 175 W MH V. Medium Base. For Use with Threaded Metal Conduit.
* Photometric data is based on a fixture with
a 150-watt clear High Pressure Sodium lamp
(16,000 lumen), without guard. For candlepower
values of fixtures with other HPS lamps, use
the following multipliers:
for a 100 W (9,500 lumen) HPS lamp – 0.594; for

Lighting

Zone

Lumens

Total Luminaire Efficiency = 77.5%

0-10
10-20
20-30

32.97
119.16
313.87

CIE Type - General Diffuse

30-40

349.57

40-50

804.55

50-60

1193.29

% Ceiling Rcc

60-70

1327.33

% Walls

70-80

1576.23

Zonal Lumen Summary

80-90
90-100
100-110
110-120
120-130
130-140
140-150
150-160
160-170
170-180

1672.01
1647.69
1507.22
1221.25
607.81
27.17
1.62
0.35
0.07
0.02

Zone
Lumens % Lamp % Fixture
0-30
465.99
2.9
3.8
0-40
815.56
5.1
6.6
0-60
2813.41
17.6
22.7
0-90
7388.98
46.2
59.6
90-120 4376.17
27.4
35.3
90-130 4983.97
31.1
40.2
90-150 5012.76
31.3
40.2
90-180 5013.20
31.3
40.4
180-0 12402.18
77.5
100.0

Zone

Lumens

Total Luminaire Efficiency = 66.9%

249.34

CIE Type - Direct

0-10

Lighting: Explosionproof — Area — HID

a 70 W (6,400 lumen) HPS lamp – 0.394;
for a 70 W (5800 lumen) HPS lamp – 0.363;
for a 50 W (4,000 lumen) HPS lamp – 0.25;
for a 35 W (2,250 lumen) HPS lamp – 0.141.
For candlepower values of fixture with guard,
multiply by 0.95.

Coefficients of Utilization - Zonal Cavity Method
Effective Floor Cavity Reflectance 0.20

10-20

810.25

20-30

1450.35

30-40

1495.68

0-180

1.44

40-50

1920.69

90-270

1.44

50-60

2259.61

Diagonal

1.80

60-70

1846.14

70-80

541.69

80-90
90-100
100-110
110-120
120-130
130-140
140-150
150-160
160-170
170-180

125.07
0.70
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00

Zone

Lumens

0-10

58.31

Spacing
Criteria

Plane

Total Luminaire Efficiency = 61.8%

10-20

482.43
904.49

30-40

1163.85

0-180

2.08

40-50

1479.08

90-270

1.38

50-60

1630.56

Diagonal

1.54

60-70

1467.51

70-80

1258.91

1214

Plane

Spacing
Criteria

Zonal Lumen Summary
Lumens % Lamp % Fixture
1445.23
9.0
14.6
2609.08 16.3
26.4
5718.73 35.7
57.8
9522.24 59.5
96.3
361.80
2.3
3.7
370.13
2.3
3.7
370.23
2.3
3.7
370.23
2.3
3.7
9892.48 61.8
100.0

30

10

0

72
64
57
51
46
42
39
36
33
31

66
55
47
40
35
31
28
25
23
21

61
48
39
32
27
23
20
18
16
14

57
42
33
26
21
18
15
13
11
10

67
58
52
47
42
39
36
33
31
29

61
51
43
37
32
29
26
23
21
19

57
44
36
30
25
22
19
17
15
13

53
39
30
24
20
17
14
12
10
9

52
43
36
31
27
24
21
19
18
16

49
38
30
25
21
18
16
14
12
11

45
33
26
21
17
14
12
10
9
8

44
35
30
25
22
20
18
16
15
13

41
31
25
21
17
15
13
11
10
9

38
28
21
17
14
11
10
8
7
6

36
29
24
20
18
16
14
13
12
11

34
26
20
16
14
12
10
9
8
7

32
23
17
13
11
9
7
6
6
5

28
19
14
10
8
6
5
4
4
3

Coefficients of Utilization - Zonal Cavity Method
Effective Floor Cavity Reflectance 0.20
% Ceiling Rcc

80

70

50

30

10

0

Rw 70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0
0 80 80 80 80 78 78 78 78 74 74 74 71 71 71 68 68 68 67
1
2
3
4
5
6
7
8
9
10

73
66
59
54
49
45
42
39
36
34

69
60
52
45
40
36
32
29
27
24

66
55
46
39
34
30
26
23
21
19

64
51
42
35
29
25
22
19
17
15

71
64
58
52
48
44
40
38
35
33

68
59
51
45
39
35
32
29
26
24

65
54
46
39
33
29
26
23
21
19

63
51
41
34
29
25
22
19
17
15

65
56
49
43
38
34
31
28
25
23

63
53
44
38
33
29
25
23
20
19

61
49
41
34
29
25
21
19
17
15

62
54
47
41
37
33
30
27
25
23

61
51
43
37
32
28
25
22
20
18

59
48
40
33
28
24
21
19
17
15

60
52
45
40
35
32
29
26
24
22

59
49
42
36
31
27
24
22
20
18

57
47
39
33
28
24
21
19
17
15

56
46
38
31
27
23
20
17
15
14

REPORT NUMBER: CJL15AN
Lamps: 150 W High Pressure Sodium lamp with
30° Angle Dome Reflector
Coefficients of Utilization - Zonal Cavity Method
Effective Floor Cavity Reflectance 0.20
% Ceiling Rcc
% Walls

Zone
0-30
0-40
0-60
0-90
90-120
90-130
90-150
90-180
180-0

50

REPORT NUMBER: CJL15ST
Lamps: 150 W High Pressure Sodium lamp with
Standard Dome Reflector

Lumens % Lamp % Fixture
2509.94 15.7
23.5
4005.62 25.0
37.4
8185.92 51.2
76.5
10698.82 66.9
100.0
0.70
0.0
0.0
0.70
0.0
0.0
0.70
0.0
0.0
0.70
0.0
0.0
10699.52 66.9
100.0

CIE Type - Direct

70

Rw 70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0
1
2
3
4
5
6
7
8
9
10

Zonal Lumen Summary
Zone
0-30
0-40
0-60
0-90
90-120
90-130
90-150
90-180
180-0

80

0 85 85 85 85 79 79 79 79 69 69 69 59 59 59 50 50 50 46

% Walls

20-30

80-90
1077.10
90-100
153.91
100-110
155.65
110-120
52.23
120-130
8.33
130-140
0.10
140-150
0.00
150-160
0.00
160-170
0.00
170-180
0.00

REPORT NUMBER: CJL15G
Lamps: 150 W High Pressure Sodium lamp with Globe only *

80

70

50

30

10

0

Rw 70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0
0 73 73 73 73 71 71 71 71 67 67 67 64 64 64 61 61 61 60
1 64 59 55 52 61 58 54 51 54 51 49 51 49 47 49 47 45 43
2
3
4
5
6
7
8
9
10

56
51
46
42
38
35
33
30
28

50
43
37
32
29
26
23
21
19

44
36
30
26
22
20
17
16
14

40
31
25
21
18
15
13
12
10

54
49
44
40
37
34
31
29
27

48
41
36
32
28
25
23
21
19

43
36
30
25
22
19
17
15
14

39
31
25
21
18
15
13
12
10

46
39
34
30
27
24
22
20
18

41
34
29
25
21
19
17
15
13

38
30
24
20
17
15
13
11
10

43
37
32
28
25
23
21
19
17

39
33
28
24
21
18
16
14
13

36
29
24
20
17
15
13
11
10

41
35
30
27
24
22
20
18
17

38
31
26
23
20
17
16
14
13

35
28
23
19
17
14
12
11
10

33
27
22
18
15
13
11
10
9

Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

Code•Master Jr.™ HID Factory Sealed Luminaire PSMH Photometric Data
Explosionproof, Dust-Ignitionproof

Integrally Ballasted. 50 W, 70 W, 100 W, 150 W HPS; 50 W, 70 W, 100 W, 175 W PSMH. 175 W MH V. Medium Base. For Use with Threaded Metal Conduit.
* Photometric data is based on a fixture with
a 175-watt clear Pulse Start Metal Halide
lamp (14,000 lumen), without guard. For
candlepower values of fixtures with other
PSMH lamps, use the following multipliers:
for a 100 W (8,500 lumen) PSMH lamp – 0.607;
Zone
0-10
10-20
20-30

Lumens

Total Luminaire Efficiency = 77.8%

46.64
176.99
380.01

CIE Type - General Diffuse

for a 70 W (5,000 lumen) PSMH lamp – 0.357.
For candlepower values of fixture with guard,
multiply by – 0.95.

REPORT NUMBER: CJP17G
Lamps: 175 W Pulse Start Metal Halide with Globe only *
Coefficients of Utilization - Zonal Cavity Method

30-40

480.30

40-50

1042.35

50-60

1252.88

% Ceiling Rcc

60-70

1378.40

% Walls

70-80

1611.81

80-90
90-100
100-110
110-120
120-130
130-140
140-150
150-160
160-170
170-180

1741.68
1758.28
1643.71
1371.76
694.24
27.13
3.14
0.67
0.08
0.03

Zone

Lumens

Total Luminaire Efficiency = 66.4%

281.17

CIE Type - Direct

1567.70

30-40

1691.30

0-180

1.42

40-50

2211.91

90-270

1.42

50-60

2339.53

Diagonal

1.76

60-70

1900.87

70-80

568.93

80-90
90-100
100-110
110-120
120-130
130-140
140-150
150-160
160-170
170-180

145.98
1.23
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00

Zone

Spacing
Criteria

Plane

Total Luminaire Efficiency = 63.2%

238.28

CIE Type - Direct

10-20

739.68

20-30

1242.92

30-40

1491.36

0-180

2.10

40-50

1770.34

90-270

1.60

50-60

1739.56

Diagonal

1.62

60-70

1484.79

70-80

1197.57
689.02
254.20
105.48
35.72
41.95
8.72
6.06
4.53
2.20
0.68

Plane

Spacing
Criteria

Zonal Lumen Summary
Lumens % Lamp % Fixture
2220.87 12.7
20.1
3712.23 21.2
33.6
7222.13 41.3
65.3
10593.52 60.5
95.8
395.41
2.3
3.6
437.36
2.5
4.0
452.13
2.6
4.0
459.54
2.6
4.2
11053.05 63.2
100.0

Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

67
56
48
41
36
32
28
26
23
21

62
49
40
33
28
24
21
19
17
15

58
43
34
27
22
19
16
14
12
11

67
59
53
48
43
40
36
34
31
29

62
52
44
38
33
29
26
24
21
20

58
45
37
31
26
23
20
17
15
14

54
40
31
25
21
18
15
13
11
10

53
44
37
32
28
25
22
20
18
17

49
39
31
26
22
19
17
15
13
12

46
35
27
22
18
15
13
11
9
8

45
36
31
26
23
20
18
17
15
14

42
32
26
22
18
16
14
12
11
10

39
29
22
18
15
12
10
9
8
7

37
30
25
21
19
16
15
13
12
11

35
27
21
17
15
13
11
10
9
8

33
24
18
14
12
10
8
7
6
5

29
20
15
12
9
7
6
5
4
4

Effective Floor Cavity Reflectance 0.20
80

70

50

30

10

0

Rw 70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0
0 79 79 79 79 77 77 77 77 74 74 74 71 71 71 68 68 68 66
1
2
3
4
5
6
7
8
9
10

72
65
59
54
49
45
42
39
36
34

69
60
52
46
40
36
32
29
27
25

66
55
46
39
34
30
26
23
21
19

64
51
42
35
29
25
22
19
17
16

70
64
57
52
48
44
41
38
35
33

67
58
51
45
40
35
32
29
26
24

65
54
46
39
34
29
26
23
21
19

63
51
41
35
29
25
22
19
17
16

65
56
49
43
38
34
31
28
26
24

63
52
44
38
33
29
26
23
21
19

61
49
41
34
29
25
22
19
17
15

62
54
47
41
37
33
30
27
25
23

60
51
43
37
32
28
25
22
20
18

59
48
40
34
29
25
22
19
17
15

60
52
45
40
35
32
29
26
24
22

58
49
42
36
31
28
25
22
20
18

57
47
39
33
28
24
21
19
17
15

56
46
38
32
27
23
20
18
16
14

REPORT NUMBER: CJP17AN
Lamps: 175 W Pulse Start Metal Halide with
30° Angle Dome Reflector *
Coefficients of Utilization - Zonal Cavity Method
Effective Floor Cavity Reflectance 0.20
% Ceiling Rcc
% Walls

Zone
0-30
0-40
0-60
0-90
90-120
90-130
90-150
90-180
180-0

73
64
57
52
47
43
40
37
34
32

% Ceiling Rcc

Lumens % Lamp % Fixture
2763.57 15.8
23.8
4454.87 25.5
38.3
9006.31 51.5
77.5
11622.09 66.4
100.0
1.23
0.0
0.0
1.23
0.0
0.0
1.23
0.0
0.0
1.23
0.0
0.0
11623.32 66.4
100.0

Lumens

0

Coefficients of Utilization - Zonal Cavity Method

Zonal Lumen Summary

0-10

10

REPORT NUMBER: CJP17ST
Lamps: 175 W Pulse Start Metal Halide with
Standard Dome Reflector *

% Walls
Zone
0-30
0-40
0-60
0-90
90-120
90-130
90-150
90-180
180-0

30

80

70

50

30

10

0

Rw 70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0
0 75 75 75 75 73 73 73 73 69 69 69 65 65 65 62 62 62 61
1
2
3
4
5
6
7
8
9
10

66
60
54
49
45
41
38
35
33
31

63
53
46
41
36
32
29
26
24
22

59
48
40
34
30
26
23
21
19
17

56
44
36
30
25
22
19
17
15
13

64
58
52
47
43
40
37
34
32
30

61
52
45
39
35
31
28
26
24
22

58
47
40
34
29
26
23
20
18
17

55
43
35
29
25
21
19
17
15
13

58
49
43
38
33
30
27
25
23
21

55
45
38
33
28
25
22
20
18
16

53
42
34
29
24
21
18
16
15
13

55
47
41
36
32
29
26
24
22
20

53
43
37
31
27
24
21
19
17
16

51
41
33
28
24
21
18
16
14
13

52
44
39
34
30
27
25
23
21
19

50
42
35
30
26
23
21
19
17
15

49
39
32
27
23
20
18
16
14
13

47
38
31
26
22
19
16
14
13
12

1215

Lighting: Explosionproof — Area — HID

914.71

20-30

80-90
90-100
100-110
110-120
120-130
130-140
140-150
150-160
160-170
170-180

1
2
3
4
5
6
7
8
9
10

Lumens % Lamp % Fixture
603.64
3.4
4.4
1083.94
6.2
8.0
3379.18 19.3
24.8
8111.07 46.3
59.6
4773.75 27.3
35.1
5467.99 31.2
40.2
5498.26 31.4
40.2
5499.05 31.4
40.4
13610.12 77.8
100.0

10-20

50

0 85 85 85 85 79 79 79 79 69 69 69 59 59 59 51 51 51 46

Zonal Lumen Summary
Zone
0-30
0-40
0-60
0-90
90-120
90-130
90-150
90-180
180-0

70

Rw 70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0

Lighting

0-10

Effective Floor Cavity Reflectance 0.20
80

Code•Master 2™ HID Factory Sealed Luminaires
Explosionproof, Dust-Ignitionproof

Integrally Ballasted. 50 W, 70 W, 100 W, 150 W, 250 W, 400 W HPS; 175 W, 250 W, 320 W, 350 W, 400 W PSMH; 175 W, 250 W, 400 W MH V.
Mogul Base. For use with threaded metal conduit.
NEC:
Class I, Division 1 and 2, Groups C, D
Class II, Division 1 and 2, Groups E, F, G
Class III
Marine Type Electric Fixtures
Outside Type (Salt Water)

CEC: V
Class I, Division 1 and 2, Groups B, C, D
Class I, Zone 1 and 2; IIB, IIA
Class II, Division 1, Groups E, F, G
Class II, Division 2, Groups F, G
Class III

CSA Type 4X
Exd IIB, Zone 1

Applications
•	 Ideal for use in chemical and petrochemical plants, such as
manufacturers of plastics, paints and thinners; in refineries; and
in other process areas where ignitable vapors, dust, moisture
and corrosive elements may be present.
•	 Suitable for use in wet locations.

Lighting: Explosionproof — Area — HID

Lighting

Features
•	 Fixtures operate safely in high ambient temperatures. For
example, in Class I areas the 150 W HPS fixture operates 	
at a maximum temperature of 248 ˚ F/120 °C in a 149 ˚F/	
65 °C ambient (212 ˚F/100 °C temperature in a 104 °F/40 °C
ambient).
•	 Arrangement of heat-producing components results in 	
more efficient heat dissipation for cooler fixture operation.
•	 Patented “wireless” design. Threading of fixture unit onto
mounting hood makes electrical connection. Only wiring
required is attaching two wires to connection block in mounting
hood.
•	 Connection block is easily wired: (a) loosen two screws, (b)
make wire connections and (c) re-position connection block.
•	 Safe, easy servicing without disconnecting any wiring.
“Wireless” fixture unit easily threads off mounting hood for
convenient servicing or for immediate replacement with a
“stand-by” unit.
•	 Acme double-lead threads speed installation and fixture
removal from mounting hood – only half as many turns are
required as for single-lead threads. The threads do not stick or
gall, eliminating the troublesome problems often encountered
with single lead threads during fixture unit removal.
•	 All threaded joints are flame-tight.
•	 Integrally ballasted HID lighting fixtures; separate ballasts 	
not required.
•	 Factory sealed. External seals not required.
•	 Strategic location of lamp socket in combination with the
interior prism design of the glass globe provides optimum 	
light distribution and control.
•	 Superior corrosion resistance, with epoxy powder coat finish.
•	 Porcelain socket with nickel-plated phosphor bronze 	
screw shell. Assures long trouble-free operation in high ambient
areas.
•	 Choice of mountings: pendant, ceiling, bracket and stanchion.
•	 Fiberglass-reinforced polyester reflectors, in standard
dome, deep dome or 30° angle, are ideal in installations
where luminaire is subject to exceptionally severe corrosive
atmospheres. The high bay aluminum reflector is indicated in
installations where mounting height from work plane ranges
from 20 feet/6 meters and higher.
•	 Optional guards protect globes from damage. Secured to fixture
with three screws.
•	 Light sources: high pressure sodium, pulse start metal halide or
metal halide. HPS is excellent where long lamp life is required.
HPS provides high lumens per watt and is less expensive to
operate. PSMH/MH is desirable where colors of illuminated
areas must be close to natural. PSMH/MH provides better color
rendition, increased lumen output, longer lamp life, and faster
restrike after momentary power interruption.
•	 A wide range of ballasts and voltages are available for both
domestic and export applications.
•	 Ballasts operate at low temperatures – PSMH: -20 °F/-29 ˚C; 	
HPS: -40 °F/-40 ˚C; MH: -31 °F/-35 ˚C.
•	 50 W through 150 W high pressure sodium ballasts are high
reactance, high power factor type.

1216

Standard Materials
•	 Ballast bodies and guards: copperfree (4/10 of 1% max.)
aluminum
•	 Pendant mounting hoods: diecast copperfree (4/10 of 1% max.)
aluminum
•	 Ceiling, bracket and stanchion mounting hoods: sand cast
copperfree (4/10 of 1% max.) aluminum
•	 Reflectors: aluminum or fiberglass reinforced polyester

Standard Finishes
•	 Ballast bodies, guards and mounting hoods: epoxy powder 	
coat finish, electrostatically applied for complete, uniform
corrosion protection

Options
•	 Fuses for field installation can be ordered by catalog number
from fuse kit table.
•	 Quartz Auxiliary Emergency Lamp for PSMH/MH and HPS
fixtures. Relay switch installed in fixture. Add suffix -E to fixture
catalog number.
•	 Smart Hot Restrike Option available for 50 W through 150 W
HPS only. Add suffix -SR.
•	 Hot Restrike Option available for 50 W through 150 W HPS only.
Add suffix –R.
•	 Smart Starter Option available for 50 W through 400 W HPS
and PSMH/MH. Add suffix –S.

Certifications and Compliances
•	
•	
•	
•	

UL Standard: UL 1598, UL 844
UL Listed: E10444
CSA Standard: C22.2 No. 250, C22.2 No. 137
CSA Certified: 025428

V CSA Certification only.
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

Code•Master 2™ HID Factory Sealed Luminaire Technical Data
Explosionproof, Dust-Ignitionproof

Integrally Ballasted. 50 W, 70 W, 100 W, 150 W, 250 W, 400 W HPS; 175 W, 250 W, 320 W, 350 W, 400 W PSMH; 175 W, 250 W, 400 W MH V.
Mogul Base. For use with threaded metal conduit.

NEC:
Class I, Division 1 and 2, Groups C, D
Class II, Division 1 and 2, Groups E, F, G
Class III
Marine Type Electric Fixtures
Outside Type (Salt Water)

CSA Type 4X
Exd IIB, Zone 1

CEC: V
Class I, Division 1 and 2, Groups B, C, D
Class I, Zone 1 and 2; IIB, IIA
Class II, Division 1, Groups E, F, G
Class II, Division 2, Groups F, G
Class III

Classified Area Suitability of Code•Master 2 Series HID Fixtures — Suitability includes use of reflector

Lamp
Type

Lamp
Watts

Class I, Division 1 & 2 With Globe or with
Globe & Reflector UL/NEC/CEC Temp. Ident. No.
Supply Wire Ambient Temp
NEC
CEC V
(°F/˚°C)
(°F/°˚C)
Nameplate Marking
Groups
Groups

50

Metal Halide V

Nameplate Marking

Groups

C,D

B, C, D

T4

E,F,G

50

167/75

131/55

T5

C,D

B, C, D

—

—

50

185/85

149/65

T5

C,D

B, C, D

—

—

70

140/60

104/40

T6

C,D

B, C, D

T4

E,F,G

70

167/75

131/55

T5

C,D

B, C, D

—

—

70

185/85

149/65

T5

C,D

B, C, D

—

—

100

122/60

104/40

T5

C,D

B, C, D

T4

E,F,G

100

167/75

131/55

T5

C,D

B, C, D

—

—

100

185/85

149/65

T4A

C,D

B, C, D

—

—

150

122/60

104/40

T5

C,D

B, C, D

T3A

E,F

150

167/75

131/55

T4A

C,D

B, C, D

T3

—

250

167/75

104/40

T3C

C,D

B, C, D

—

—

250

167/75

131/55

T3C

C,D

B, C, D

—

—

400

185/85

104/40

T3C

C,D

B, C, D

—

—

175

167/75

104/40

T4

C,D

B, C, D

T3C

E,F,G

250

167/75

104/40

T4

C,D

B, C, D

T3A

E,F

320

167/75

104/40

T3C

C,D

B, C, D

—

—

350

167/75

104/40

T3C

C,D

B, C, D

—

—

400

167/75

104/40

T3C

C,D

B, C, D

—

—

175

167/75

104/40

T4

­—

B, C, D

T3C

E, F, G

250

167/75

104/40

T4

—

B, C, D

T3A

E, F

400

167/75

104/40

T3C

—

B, C, D

—

—

Lighting: Explosionproof — Area — HID

Pulse Start
Metal Halide

T6

104/40

Lighting

High
Pressure
Sodium

122/60

Class II, Division 1 & 2
With Globe or with Globe & Reflector
UL/NEC/CEC Temp. Ident. No. ➊

“T” Numbers Represent the Maximum Surface Temperature for Class I, Division 1 Locations and
Maximum Surface Temperature Under Dust Blanket for Class II, Division 1 Locations.
“T”
Number

T1

350

325

T2

T2A

T2B

T2C

T2D

T3

T3A

T3B

T3C

T4

T4A

T5

T6

Temp.
Range
(°F)

664842

619662

574617

538572

502536

448500

421446

394419

358392

331356

322329

277320

250275

214248

18712

185

Temp.
Range
(°C)

351450

326350

301325

281300

261280

231260

216230

201215

181200

166180

161165

136160

121135

101120

86100

85

NOTE: The maximum operating temperature of the fixture must not exceed the ignition temperature of the gas, vapor or dust to be encountered per the National
Electrical Code and the Canadian Electrical Code.
➊ Applies to Code•Master 2 only.
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

1217

Code•Master 2™ HID Factory Sealed Luminaires

Explosionproof, Dust-Ignitionproof. Groups C and D Applications

Integrally Ballasted. 50 W, 70 W, 100 W, 150 W, 250 W, 400 W HPS; 175 W, 250 W, 320 W, 350 W, 400 W PSMH.
Mogul Base. For use with threaded metal conduit.
NEC:
Class I, Division 1 and 2, Groups C, D
Class II, Division 1 and 2, Groups E, F, G
Class III
Marine Type Electric Fixtures
Outside Type (Salt Water)

Lamp
Watts

ANSI Lamp Type
HPS

PSMH

S68

—

Catalog Number ➋➌

Hub Size
(Inches)

HPS

PSMH

3/4

CLP5075 ➊

—

1

CLP5010 ➊

—

3/4

CLP7075

—

Pendant — One Hub, Rigid or Flexible Mounting
50
70
100

Lighting: Explosionproof — Area — HID

Lighting

150
175

S62
S54
S55
—

—
—
—
M152

250

S50

M153

320

—

M154

350

—

M131

400

S51

M155

50

S68

—

1

CLP7010

—

3/4

CLP1075

—

1

CLP1010

—

3/4

CLP1575

—

1

CLP1510

3/4
1

—

—

CPP1775

—

CPP1710

3/4

CLP2575

CPP2575

1

CLP2510

CPP2510
CPP3275

3/4

—

1

—

CPP3210

3/4

—

CPP3575

1

—

CPP3510

3/4

CLP4075

CPP4075

1

CLP4010

CPP4010

Ceiling — Four Hubs, Three Close-Up Plugs

70

S62

—

100

S54

—

150

S55

—

175

—

M152

250
320
350
400

S50
—
—
S51

M153
M154
M131
M155

3/4

CLC5075 ➊

—

1

CLC5010 ➊

—

3/4

CLC7075

—

1

CLC7010

—

3/4

CLC1075

—

1

CLC1010

—

3/4

CLC1575

—

1

CLC1510

—

3/4

—

CPC1775

1

—

CPC1710

3/4

CLC2575

1

CLC2510

3/4

—

CPC2575
CPC2510
CPC3275

1

—

CPC3210

3/4

—

CPC3575

—

CPC3510

1
3/4

CLC4075

CPC4075

1

CLC4010

CPC4010

➊ Add voltage -MT for 120/208/240/277 V. For 480 V, contact your sales representative.
➋ Add voltage suffix -MT for -120/208/240/277 V; or -480 for 480 V.
 To order fixture with guard, add suffix -G (before adding voltage suffix).
 Shaded items are suitable for Class I, Group D ONLY.

1218

Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

Code•Master 2™ HID Factory Sealed Luminaires

Explosionproof, Dust-Ignitionproof. Groups C and D Applications

Integrally Ballasted. 50 W, 70 W, 100 W, 150 W, 250 W, 400 W HPS; 175 W, 250 W, 320 W, 350 W, 400 W PSMH.
Mogul Base. For use with threaded metal conduit.
NEC:
Class I, Division 1 and 2, Groups C, D
Class II, Division 1 and 2, Groups E, F, G
Class III
Marine Type Electric Fixtures
Outside Type (Salt Water)

ANSI Lamp Type

Lamp
Watts

HPS

PSMH

50

S68

—

70

S62

—

Catalog Number ➋➌

Hub Size
(Inches)

HPS

PSMH

3/4

CLB5075 ➊

—

1

CLB5010 ➊

—

3/4

CLB7075

—

1

CLB7010

—

3/4

CLB1075

—

1

CLB1010

—

3/4

CLB1575

—

1

CLB1510

Bracket - Four Hubs, Three Close-Up Plugs

100
150

—

S55
—

—
M152

S50

M153

320

—

M154

350

—

M131

—

CPB1775 ➋

1

—

CPB1710 ➋

3/4

CLB2575

CPB2575 ➋

1

CLB2510

CPB2510 ➋

3/4

—

CPB3275 ➋

1

—

CPB3210 ➋

3/4

—

CPB3575 ➋

1

—

CPB3510 ➋

3/4

CLB4075

CPB4075 ➋

1

CLB4010

CPB4010 ➋

400

S51

M155

50

S68

—

1-1/4 or 1-1/2 ➍

CLS50150 ➊

—

70

S62

—

1-1/4 or 1-1/2 ➍

CLS70150

—

100

S54

—

1-1/4 or 1-1/2 ➍

CLS10150

—

150

S55

—

1-1/4 or 1-1/2 ➍

CLS15150

—

175

—

M152

1-1/4 or 1-1/2 ➍

250

S50

M153

1-1/4 or 1-1/2 ➍

320

—

M154

1-1/4 or 1-1/2 ➍

—

CPS32150 ➋

350

—

M131

1-1/4 or 1-1/2 ➍

—

CPS35150 ➋

400

S51

M155

1-1/4 or 1-1/2 ➍

CLS40150 ➋

CPS40150 ➋

25° Stanchion - One Hub

—
CLS25150

CPS17150 ➋
CPS25150 ➋

➊ Add voltage -MT for 120/208/240/277 V. For 480 V, contact your sales representative.
➋ Add voltage suffix -MT for -120/208/240/277 V; or -480 for 480 V.
 To order fixture with guard, add suffix -G (before adding voltage suffix).
➍ 1-1/2” tapped hub furnished with 1-1/2” to 1-1/4” reducer.
 Shaded items are suitable for Class I, Group D ONLY.
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

1219

Lighting: Explosionproof — Area — HID

250

—

3/4

Lighting

175

S54

Code•Master 2™ HID Factory Sealed Luminaires V

Explosionproof, Dust-Ignitionproof. Groups B, C and D Applications

Integrally Ballasted. 70 W, 100 W, 150 W, 250 W, 400 W HPS; 175 W, 250 W, 320 W, 350 W, 400 W PSMH; 175 W, 250 W, 400 W MH.
Mogul Base. For use with threaded metal conduit.
CSA Type 4X
Exd IIB, Zone 1

CEC: V
Class I, Division 1 and 2, Groups B, C, D
Class I, Zone 1 and 2; IIB, IIA
Class II, Division 1, Groups E, F, G
Class II, Division 2, Groups F, G
Class III

ANSI Lamp Type
Lamp
Watts

HPS

PSMH

MH

S62

—

—

Hub
Size
(Inches)

Catalog Number ❶❷
HPS

PSMH

MH

3/4

CLP7075TTCN

—

—

1

CLP7010TTCN

—

—

3/4

CLP1075TTCN

—

—

1

CLP1010TTCN

—

—

3/4

CLP1575TTCN

—

—

1

CLP1510TTCN

—

Pendant — One Hub, Rigid or Flexible Mounting
70
100

S54

—

—

150

S55

—

—

Lighting

175
250

Lighting: Explosionproof — Area — HID

320
350
400

—
S50
—
—

M152
M153
M154
M131

M57
M58
—
—

S51

M155

M59

S62

—

—

3/4

—

—

CPP1775TTCN

CHP1775TTCN

—

CPP1710TTCN

CHP1710TTCN

3/4

CLP2575TTCN

CPP2575TTCN

CHP2575TTCN

1

CLP2510TTCN

CPP2510TTCN

CHP2510TTCN

1

3/4

—

CPP3275TTCN

—

1

—

CPP3210TTCN

—

3/4

—

CPP3575TTCN

—

—

CPP3510TTCN

1

—

3/4

CLP4075TTCN

CPP4075TTCN

CHP4075TTCN

1

CLP4010TTCN

CPP4010TTCN

CHP4010TTCN

3/4

CLC7075TTCN

—

—

1

CLC7010TTCN

—

—

3/4

CLC1075TTCN

—

—

1

CLC1010TTCN

—

—

3/4

CLC1575TTCN

—

—

1

CLC1510TTCN

Ceiling — Four Hubs, Three Close-Up Plugs
70
100
150
175
250
320

S54
S55
—
S50
—

—
—
M152
M153
M154

—
—
M57
M58
—

350

—

M131

—

400

S51

M155

M59

3/4

—

—

—

CPC1775TTCN

CHC1775TTCN

—

CPC1710TTCN

CHC1710TTCN

3/4

CLC2575TTCN

CPC2575TTCN

CHC2575TTCN

1

CLC2510TTCN

CPC2510TTCN

CHC2510TTCN

1

3/4

—

CPC3275TTCN

—

1

—

CPC3210TTCN

—

3/4

—

CPC3575TTCN

—

1

—

CPC3510TTCN

—

3/4

CLC4075TTCN

CPC4075TTCN

CHC4075TTCN

1

CLC4010TTCN

CPC4010TTCN

CHC4010TTCN

➊ Change voltage suffix -TT (120/277/347 V) to -MT for 120/208/240/277 V, -C2 for 208 V, -C3 for 240 V, -C6 for 480 V, or -C7 for 600 V, V
❷ To order fixture with guard, add suffix -G (before adding voltage suffix).
V CSA Certification only.
 Shaded items are suitable for Class I, Group D ONLY.

1220

Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

Code•Master 2™ HID Factory Sealed Luminaires V

Explosionproof, Dust-Ignitionproof. Groups B, C and D Applications

Integrally Ballasted. 70 W, 100 W, 150 W, 250 W, 400 W HPS; 175 W, 250 W, 320 W, 350 W, 400 W PSMH; 175 W, 250 W, 400 W MH.
Mogul Base. For use with threaded metal conduit.
CSA Type 4X
Exd IIB, Zone 1

CEC: V
Class I, Division 1 and 2, Groups B, C, D
Class I, Zone 1 and 2; IIB, IIA
Class II, Division 1, Groups E, F, G
Class II, Division 2, Groups F, G
Class III

ANSI Lamp Type
Lamp
Watts

HPS

PSMH

MH

Hub
Size
(Inches)

Catalog Number ❶❷
HPS

PSMH

MH

Bracket - Four Hubs, Three Close-Up Plugs
70

S62

—

—

100

S54

—

—

150

S55

—

—

175

—

M152

M57

320

—
—

M153

M58

M154

—

M131

—

—

—

CLB7010TTCN

—

—

3/4

CLB1075TTCN

—

—

1

CLB1010TTCN

—

—

3/4

CLB1575TTCN

—

—

1

CLB1510TTCN

—

—

3/4

—

CPB1775TTCN

CHB1775TTCN

1

—

CPB1710TTCN

CHB1710TTCN

3/4

CLB2575TTCN

CPB2575TTCN

CHB2575TTCN

1

CLB2510TTCN

CPB2510TTCN

CHB2510TTCN

3/4

—

CPB3275TTCN

—

1

—

CPB3210TTCN

—

3/4

—

CPB3575TTCN

—

—

CPB3510TTCN

1

—

3/4

CLB4075TTCN

CPB4075TTCN

CHB4075TTCN

1

CLB4010TTCN

CPB4010TTCN

CHB4010TTCN

400

S51

M155

M59

70

S62

—

—

1-1/4 or 1-1/2 ➌

CLS70150TTCN

—

—

100

S54

—

—

1-1/4 or 1-1/2 ➌

CLS10150TTCN

—

—

150

S55

—

—

1-1/4 or 1-1/2 ➌

CLS15150TTCN

—

—

175

—

M152

M57

1-1/4 or 1-1/2 ➌

—

250

S50

M153

M58

1-1/4 or 1-1/2 ➌

320

—

M154

—

1-1/4 or 1-1/2 ➌

—

CPS32150TTCN

—

350

—

M131

—

1-1/4 or 1-1/2 ➌

—

CPS35150TTCN

—

400

S51

M155

M59

1-1/4 or 1-1/2 ➌

25° Stanchion - One Hub

CPS17150TTCN CHS17150TTCN

CLS25150TTCN CPS25150TTCN CHS25150TTCN

CLS40150TTCN CPS40150TTCN CHS40150TTCN

➊ Change voltage suffix -TT (120/277/347 V) to -MT for 120/208/240/277 V, -C2 for 208 V, -C3 for 240 V, -C6 for 480 V, or -C7 for 600 V, V
❷ To order fixture with guard, add suffix -G (before adding voltage suffix).
➌ 1-1/2” tapped hub furnished with 1-1/2” to 1-1/4” reducer.
V CSA Certification only.
 Shaded items are suitable for Class I, Group D ONLY.
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

1221

Lighting: Explosionproof — Area — HID

350

S50

CLB7075TTCN

1

Lighting

250

3/4

Code•Master 2™ HID Factory Sealed Luminaire Mounting Hoods and Fixture Units
Explosionproof, Dust-Ignitionproof

Integrally Ballasted. 50 W, 70 W, 100 W, 150 W, 250 W, 400 W HPS; 175 W, 250 W, 320 W, 350 W, 400 W PSMH; 175 W, 250 W, 400 W MH V.
Mogul Base. For use with threaded metal conduit.
NEC:
Class I, Division 1 and 2, Groups C, D
Class II, Division 1 and 2, Groups E, F, G
Class III
Marine Type Electric Fixtures
Outside Type (Salt Water)

CEC: V
Class I, Division 1 and 2, Groups B, C, D
Class I, Zone 1 and 2; IIB, IIA
Class II, Division 1, Groups E, F, G
Class II, Division 2, Groups F, G
Class III

CSA Type 4X
Exd IIB, Zone 1

Mounting Hoods
Hub Size (Inches)

Catalog Number

Pendant — One Hub
3/4

CAP-75

1

CAP-100

3/4

CAC-75

1

CAC-100

3/4

CALB-75

1

CALB-100

Lighting

Ceiling — Four Hubs, Three Close-Up Plugs

Bracket — Four Hubs, Three Close-Up Plugs

Lighting: Explosionproof — Area — HID

25˚ Stanchion — One Hub
1-1/4 or 1-1/2 ➊

CAS-150

Mounting Adapter with Connection Block
Permits use of existing A-51 mounting hoods (AAC Ceiling
or AALB Bracket) with the new Code•Master 2 Fixture Unit.
After removing existing fixture unit and adapter, screw in
the new CMAD-1 Adapter. Then thread new fixture unit into
the CMAD-1.
Fixture Units
Ballast body with globe. Indicate voltage desired by adding voltage suffix to fixture unit catalog number listed below.
Add Voltage Suffixes
Lamp
Fixture Unit
Type
Watts
Number
120/208/240/277
120/277/347 V➌
50
CMBL50
MT
TTCN
70
CMBL70
MT
TTCN
High Pressure Sodium
100
CMBL100
MT
TTCN
High Power Factor
150
CMBL150
MT
TTCN
(Min. P.F. 90%)
250
CMBL250
MT
TTCN
400
CMBL400
MT
TTCN
175
CMBP175
MT
TTCN
250
CMBP250
MT
TTCN
Pulse Start Metal Halide
Constant Wattage
320
CMBP320
MT
TTCN
(Min. P.F. 90%)
350
CMBP350
MT
TTCN
400
CMBP400
MT
TTCN
175
CMBH175
MT
TT
Metal Halide V
250
CMBH250
MT
TT
Constant Wattage
(Min. P.F. 90%)
400
CMBH400
MT
TT

CMAD-1

480 V
—
48
48
48
48
48
48
48
48
48
48
C6
C6
C6

➊ 1-1/2” Tapped hub furnished with 1-1/2” to 1-1/4” reducer.
➋ Add suffix -R for “Hot Restrike” and -S for “Smart Starter” options.
➌ Change voltage suffix -TTCN to -MTCN for 120/208/240/277 V, -C2 for 208 V, -C3 for 240 V, -C6 for 480 V, or -C7 for 600 V, V
V CSA Certification only.
 Shaded items are suitable for Class I, Group D ONLY.

1222

Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

Code•Master 2™ HID Factory Sealed Luminaire Accessories
Explosionproof, Dust-Ignitionproof

Integrally Ballasted. 50 W, 70 W, 100 W, 150 W, 250 W, 400 W HPS; 175 W, 250 W, 320 W, 350 W, 400 W PSMH; 175 W, 250 W, 400 W MH V.
Mogul Base. For use with threaded metal conduit.

Description

Catalog Number

Polyester Reflectors — 50 W - 400 W
Standard Dome

CMR-4ST

Deep Dome

CMR-4DD

30˚ Angle

CMR-4AN

Aluminum High Bay Reflectors — 50 W - 400 W
CMR-4HB

Lighting

Prismatic Glass Globes — 50 W - 400 W
CGL-250

250, 400 W HPS; 320, 350, 400 W PSMH; 400 W MH

CGL-400

50, 70, 100, 150 W HPS; 175, 250 W PSMH; 175, 250 W MH

CGU2

250, 400 W HPS; 320, 350, 400 W PSMH; 400 W MH

CGU4

Aluminum Guards — 50 W - 400 W

Replacement Sockets — 50 W - 400 W (Mogul Base)
For all Code•Master 2 HID fixtures

CMS-400

Connection Block – 50 W through 400 W
For all Code•Master 2 HID fixtures

VPT-7

Quartz Emergency Option for Pulse Start Metal Halide and High Pressure Sodium Fixtures
Fixtures can be supplied with a socket to accept a 150 W or 250 W, 120 V quartz lamp (lamp not included). This D.C. bayonet base socket is
in addition to the standard lamp socket, independent of the lighting fixture voltage.
Add suffix -E
HPS Smart Hot Restrike
Smart Hot Restrike will immediately restrike an HPS lamp when power is restored after a momentary power interruption. The smart function
removes the hot restrike ignitor from the circuit if the lamp burns out or is removed from the socket. Eliminates starter failures caused by
prolonged operation with cycling or failing lamps and simplifies finding their location, reducing maintenance and repair costs.
Optional for fixture watts of 50, 70, 100 or 150 (HPS only)

Add suffix -SR

HPS Hot Restrike
Restrikes HPS lamp immediately when power is restored after a momentary power interruption.
Optional for fixture watts of 50, 70, 100 or 150 (HPS only)

Add suffix -R

HPS Smart Starter
Smart Starter is for HPS fixtures only. Incorporates a 1-1/2-minute timer and performs as a conventional starter to normally start lamp.
Removes itself from circuit if lamp burns out or is removed from socket. Eliminates starter failures caused by prolonged operation with
cycling or failing lamps and simplifies finding their location which reduces maintenance and repair costs.
Optional for all HPS fixtures.
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

Add suffix -S

1223

Lighting: Explosionproof — Area — HID

50, 70, 100, 150 W HPS; 175, 250 W PSMH; 175, 250 W MH

Code•Master 2™ HID Factory Sealed Luminaire Ballast and Fuse Data
Explosionproof, Dust-Ignitionproof

Integrally Ballasted. 50 W, 70 W, 100 W, 150 W, 250 W, 400 W HPS; 175 W, 250 W, 320 W, 350 W, 400 W PSMH; 175 W, 250 W, 400 W MH V.
Mogul Base. For use with threaded metal conduit.
NEC:
Class I, Division 1 and 2, Groups C, D
Class II, Division 1 and 2, Groups E, F, G
Class III
Marine Type Electric Fixtures
Outside Type (Salt Water)

Lamp
Watts

50

Lighting

70

Lighting: Explosionproof — Area — HID

100

150

175

250

320

350

400

Volts
120
208
240
277
347
480
120
208
240
277
347
480
120
208
240
277
347
480
120
208
240
277
347
480
120
208
240
277
347
480
120
208
240
277
347
480
120
208
240
277
347
480
120
208
240
277
347
480
120
208
240
277
347
480

High Pressure
Sodium ➊
Start
Operating
0.58
0.58
0.35
0.33
0.31
0.29
0.25
0.25
—
—
—
—
0.90
0.82
0.50
0.48
0.44
0.44
0.35
0.36
0.30
0.30
0.21
0.21
1.30
1.15
0.76
0.67
0.66
0.58
0.60
0.50
0.45
0.39
0.33
0.29
2.00
1.66
1.16
0.96
1.00
0.83
0.88
0.75
0.52
0.56
0.50
0.44
—
—
—
—
—
—
—
—
—
—
—
—
1.75
2.70
1.00
1.50
0.85
1.30
0.75
1.15
0.60
0.93
0.40
0.65
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
3.10
3.90
1.80
2.25
1.60
1.95
1.35
1.70
1.00
1.32
0.80
1.00

CEC: V
Class I, Division 1 and 2, Groups B, C, D
Class I, Zone 1 and 2; IIB, IIA
Class II, Division 1, Groups E, F, G
Class II, Division 2, Groups F, G
Class III

Ballast Amps
Pulse Start Metal Halide
Super CWA
Start
Operating
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
1.10
1.86
0.75
1.23
0.65
0.98
0.55
0.87
0.25
0.65
0.25
0.50
1.96
2.50
1.13
1.45
0.98
1.25
0.85
1.10
0.62
0.90
0.32
0.67
3.30
3.25
1.90
1.90
1.60
1.65
1.40
1.40
0.70
1.10
0.45
0.85
3.60
3.70
2.10
2.10
1.80
1.80
1.60
1.60
0.70
1.01
0.60
0.90
3.50
4.00
2.00
2.30
1.75
2.00
1.50
1.75
1.10
1.35
0.75
1.00

Metal Halide
CWA
Start
Operating
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
1.30
1.80
0.75
1.10
0.65
0.90
0.55
0.80
0.50
0.65
—
—
1.20
2.60
0.65
1.50
0.60
1.30
0.50
1.12
0.80
0.90
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
3.25
4.00
1.90
2.30
1.65
2.00
1.40
1.75
1.20
1.40
—
—

CSA Type 4X
Exd IIB, Zone 1

Fuse Kit Catalog Number
Fuse
Quantity
Required
1
2
2
1
—
—
1
2
2
1
1
2
1
2
2
1
1
2
1
2
2
1
1
2
1
2
2
1
1
2
1
2
2
1
1
2
1
2
2
1
1
2
1
2
2
1
1
2
1
2
2
1
1
2

HPS
CF-5
CF-3
CF-3
CF-2
—
—
CF-5
CF-3
CF-3
CF-2
CF-2
CF-2
CF-8
CF-5
CF-5
CF-3
CF-3
CF-3
CF-10
CF-5
CF-5
CF-5
CF-5
CF-3
—
—
—
—
—
—
CF-8
CF-5
CF-5
CF-5
CF-5
CF-2
—
—
—
—
—
—
—
—
—
—
—
—
CF-15
CF-8
CF-5
CF-5
CF-5
CF-5

PSMH
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
CF-5
CF-3
CF-3
CF-2
CF-2
CF-2
CF-8
CF-5
CF-5
CF-3
CF-3
CF-2
CF-8
CF-6
CF-5
CF-5
CF-5
CF-3
CF-10
CF-8
CF-5
CF-5
CF-5
CF-3
CF-10
CF-8
CF-5
CF-5
CF-5
CF-3

MH V
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
CF-5
CF-3
CF-3
CF-2
CF-2
—
CF-8
CF-5
CF-5
CF-3
CF-3
—
—
—
—
—
—
—
—
—
—
—
—
—
CF-10
CF-8
CF-5
CF-5
CF-5
—

Fuse Kit includes fuse, fuse holder and necessary hardware for field installation. Mounts easily in ballast body with one screw. Order one fuse for 120 and 277 V,
and 2 fuses for 208, 240 and 480 V. CF-2 = 2 amp; CF-3 = 3 amp; CF-5 = 5 amp; CF-6 = 6 amp; CF-8 = 8 amp; CF-10 = 10 amp
➊ 50 through 150 W HPS have H.P.F. High Reactance ballasts; 250 W and 400 W HPS have CWA ballasts.
V CSA Certification only.

1224

Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

Code•Master 2™ HID Factory Sealed Luminaire Dimensions
Explosionproof, Dust-Ignitionproof

Integrally Ballasted. 50 W, 70 W, 100 W, 150 W, 250 W, 400 W HPS; 175 W, 250 W, 320 W, 350 W, 400 W PSMH; 175 W, 250 W, 400 W MH V.
Mogul Base. For use with threaded metal conduit.

Pendant

Ceiling

Bracket
0.41"/
10.4 mm Dia.

4.58"/
116.3 mm

2.46"/
62.5 mm

25° Stanchion
9.5"/
241.3 mm

2.28"/
57.9 mm

6.10"/
154.9 mm

4.25"/
108.0 mm

4.92"/
125.0 mm Sq.
4.50"/
114.3 mm

3.91"/
99.3 mm

4.00"/
101.6 mm

1.23"/
31.2 mm
3.46"/
87.9 mm

3.92"/
99.6 mm

5.92"/
151.1 mm
0.94"/
23.9 mm

9.86"/
250.4 mm

1.79"/
45.5 mm

4.5"/
60.5 mm Dia.
2.38"/
60.5 mm Dia.

11.5"/
292.1 mm
13.75"/
349.3 mm

9.86"/
250.4 mm

Lighting

9.86"/
250.4 mm

Pendant
Ceiling
Bracket
25° Stanchion
A
B
C
D
A
B
C
D
A
B
C
D
A
B
C
21.50/ 20.50/ 12.00/ 17.61/ 21.61/ 20.61/ 12.00/ 17.61/ 21.86/ 20.86/ 17.50/ 17.61/ 19.50/ 18.70/ 16.00/
50-250 W ➊ 546.1 520.7 304.8 447.3 548.9 523.5 304.8 447.3 555.2 529.8 444.5 447.3 495.3 475.0 406.4
24.50/ 23.50/ 12.00/ 20.36/ 24.36/ 23.36/ 12.00/ 20.36/ 24.61/ 23.61/ 17.50/ 20.36/ 22.20/ 21.20/
250-400 W ➋ 522.3 596.9 304.8 507.1 618.7 507.1 304.8 507.1 625.1 599.7 444.5 507.1 563.9 538.5

17.50/
444.5

Fixture and Accessory Weights lbs/kgs
Fixture Size
50 W through 175 W
250 W PSMH/MH
250 W HPS
320 W, 350 W and 400 W PSMH, 400 W MH
Mounting Hood Weights lbs/kgs

Fixture Weight
32/14.5
37/16.9
40/18.1
45/20.4

Reflector Weight
3/1.4
3/1.4
3/1.4
3/1.4

Guard Weight
1/.5
1/.5
2/.9
2/.9

Pendant
2/0.9

Ceiling
4/1.8

Bracket
6/2.7

Stanchion
2/0.9

Reflector Dimensions in In/mm
Standard and Deep Dome

30° Angle

High Bay
10.96"/
278.4 mm

10.56"/
268.2 mm

13.30"/
337.8 mm

5.00"/
127 mm

9.75"/
247.7 mm
16.16"/
410.5 mm
20.80"/
528.3 mm

➊ 50, 70, 100 and 150 W HPS; 175 W PSMH; 175 and 250 W MH.
➋ 250 and 400 W HPS; 250, 320, 350 and 400 W PSMH; 400 W MH.
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

1225

Lighting: Explosionproof — Area — HID

5.50"/
139.7 mm

Dimensions in In/mm

Code•Master 2™ HID Factory Sealed Luminaire Photometric Data
Explosionproof, Dust-Ignitionproof

Integrally Ballasted. 50 W, 70 W, 100 W, 150 W, 250 W, 400 W HPS; 175 W, 250 W, 320 W, 350 W, 400 W PSMH; 175 W, 250 W, 400 W MH V.
Mogul Base. For use with threaded metal conduit.

* Photometric data is based on a 100watt clear HPS lamp (9,500 lumens). For
candlepower values of fixtures with other
lamps, use the following multipliers: 50 W HPS
– 0.42 (4,000 lumens); 70 W HPS – 0.61 (6,300
lumens); and 150 W HPS – 1.68 (16,000 lumens).
Total Luminaire Efficiency = 76.4%
CIE Type - Semi-Direct
Plane

Spacing
Criteria

0-180

2.66

90-270

2.66

Diagonal

2.84

REPORT NUMBER: CL10G
Lamps: 100 W High Pressure Sodium with Globe only
Coefficients of Utilization - Zonal Cavity Method
Effective Floor Cavity Reflectance 0.20
% Ceiling Rcc

Lighting: Explosionproof — Area — HID

Lighting

% Walls
Zone
0-10
10-20
20-30
30-40
40-50
50-60
60-70
70-80
80-90
90-100
100-110

Lumens
29.80
106.54
202.92
318.52
468.31
670.49
866.67
976.61
1038.41
1042.18
927.00

110-120

551.82

120-130
130-140
140-150
150-160
160-170
170-180

51.82
2.51
0.25
0.00
0.00
0.00

Total Luminaire Efficiency = 71.3%
CIE Type - Direct
Plane

Spacing
Criteria

0-180

1.54

90-270

1.54

Diagonal

1.66

0
1
2
3
4
5
6
7
8
9
10

Lumens
40.00
331.02
660.22
934.51
1131.33
1272.76
1322.68
826.95
254.44
0.00
0.00

110-120

0.00

120-130
130-140
140-150
150-160
160-170
170-180

0.00
0.00
0.00
0.00
0.00
0.00

1226

70

50

30

10

0

70 50 30 10

70 50 30 10

50 30 10

50 30 10

50 30 10

0

84
72
63
56
51
46
42
39
36
33
31

79
66
58
52
47
42
39
36
33
31
29

70
53
43
36
31
28
24
22
20
18
17

61
45
37
31
26
23
21
18
17
15
14

53
38
30
25
22
19
17
15
14
13
12

84
66
54
46
40
35
31
28
25
23
21

84
61
47
38
32
27
23
20
18
16
14

84
56
41
32
26
21
18
15
13
11
10

79
61
51
43
37
32
29
26
23
21
19

79
57
44
36
30
25
22
19
17
15
13

79
52
39
30
24
20
17
14
12
11
9

70
49
38
31
25
22
19
16
14
13
12

70
46
34
26
21
17
14
12
10
9
8

61
42
32
26
22
18
16
14
12
11
10

61
40
29
22
18
14
12
10
9
8
7

53
36
27
22
18
15
13
11
10
9
8

53
34
24
18
14
12
10
8
7
6
6

49
30
21
15
12
9
7
6
5
4
4

Zonal Lumen Summary
Zone
0-30
0-40
0-60
0-90

Lumens
339.26
657.79
1796.59
4678.28

% Lamp
3.6
6.9
18.9
49.2

% Fixture
4.7
9.1
24.8
64.5

Zone
90-120
90-130
90-150
90-180
0-180

Lumens
2521.83
2572.83
2575.59
2575.59
7253.87

% Lamp
26.5
27.1
27.1
27.1
76.4

% Fixture
34.8
35.5
35.5
35.5
100.0

REPORT NUMBER: CL10ST
Lamps: 100 W High Pressure Sodium with Standard Dome Reflector
Coefficients of Utilization - Zonal Cavity Method
Effective Floor Cavity Reflectance 0.20
% Ceiling Rcc
% Walls

Zone
0-10
10-20
20-30
30-40
40-50
50-60
60-70
70-80
80-90
90-100
100-110

Rw

80

Rw
0
1
2
3
4
5
6
7
8
9
10

80

70

50

30

10

0

70 50 30 10

70 50 30 10

50 30 10

50 30 10

50 30 10

0

85
76
67
60
54
49
45
41
38
35
33

83
74
65
58
52
48
43
40
37
34
32

79
67
56
48
41
36
32
29
26
24
22

76
64
54
46
40
35
31
28
25
23
21

73
61
51
44
38
33
30
27
24
22
20

85
71
60
51
44
39
34
30
27
25
23

85
68
54
44
37
31
27
23
21
18
17

85
64
49
39
31
26
22
19
16
14
12

83
70
59
50
43
38
33
30
27
24
22

83
66
53
44
36
31
27
23
20
18
16

83
63
49
38
31
26
22
18
16
14
12

79
64
51
42
35
30
26
23
20
18
16

79
61
47
38
31
25
21
18
16
14
12

76
61
50
41
34
29
25
22
20
18
16

76
59
46
37
30
25
21
18
16
14
12

73
59
48
40
33
29
25
22
19
17
15

73
57
45
36
30
25
21
18
16
14
12

71
56
43
34
28
23
19
16
14
12
11

Zonal Lumen Summary
Zone
0-30
0-40
0-60
0-90

Lumens
1031.23
1965.74
4369.83
6773.90

% Lamp
10.9
20.7
46.0
71.3

% Fixture
15.2
29.0
64.5
100.0

Zone
90-120
90-130
90-150
90-180
0-180

Lumens
0.00
0.00
0.00
0.00
6773.90

% Lamp
0.0
0.0
0.0
0.0
71.3

% Fixture
0.0
0.0
0.0
0.0
100.0

Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

Code•Master 2™ HID Factory Sealed Luminaire Photometric Data
Explosionproof, Dust-Ignitionproof

Integrally Ballasted. 50 W, 70 W, 100 W, 150 W, 250 W, 400 W HPS; 175 W, 250 W, 320 W, 350 W, 400 W PSMH; 175 W, 250 W, 400 W MH V.
Mogul Base. For use with threaded metal conduit.

* Photometric data is based on a 100-watt
clear High Pressure Sodium lamp (9,500
lumens). For candlepower values of fixtures
with other lamps, use the following multipliers:
50 W HPS – 0.42 (4,000 lumens); 70 W HPS
– 0.61 (6,300 lumens); and 150 W HPS – 1.68
Total Luminaire Efficiency = 61.9%
CIE Type - Direct
Plane

Spacing
Criteria

0-180

1.96

90-270

1.62

Diagonal

1.50

(16,000 lumens).

REPORT NUMBER: CL10AN
Lamps: 100 W High Pressure Sodium with 30° Angle Dome Reflector
Coefficients of Utilization - Zonal Cavity Method
Effective Floor Cavity Reflectance 0.20
% Ceiling Rcc
% Walls

110-120

0.00

120-130
130-140
140-150
150-160
160-170
170-180

0.00
0.00
0.00
0.00
0.00
0.00

Total Luminaire Efficiency = 37.8%
CIE Type - Direct
Plane

Spacing
Criteria

0-180

1.36

90-270

1.36

Diagonal

1.54

0
1
2
3
4
5
6
7
8
9
10

Lumens
26.07
224.04
437.71
551.18
656.83
743.35
592.81
265.53
94.52
0.00
0.00

110-120

0.00

120-130
130-140
140-150
150-160
160-170
170-180

0.00
0.00
0.00
0.00
0.00
0.00

30

10

0

50 30 10

50 30 10

50 30 10

0

74
64
57
51
47
42
39
36
33
31
29

72
62
55
50
45
41
38
35
32
30
28

69
56
47
40
35
31
28
25
22
20
19

66
53
45
38
34
30
26
24
22
20
18

63
51
43
37
32
28
25
23
21
19
18

74
60
51
43
38
33
29
26
24
22
20

74
56
45
37
31
27
23
20
18
16
14

74
53
41
32
26
22
19
16
14
12
11

72
59
49
42
37
32
29
26
23
21
19

72
55
44
37
31
26
23
20
18
16
14

72
52
40
32
26
22
18
16
14
12
11

69
53
43
35
30
26
22
20
17
15
14

69
50
39
31
26
21
18
16
14
12
11

66
51
41
34
29
25
22
19
17
15
14

66
49
38
31
25
21
18
16
14
12
11

63
49
40
33
28
24
21
19
17
15
13

63
47
37
30
25
21
18
15
13
12
11

62
46
36
28
23
19
16
14
12
11
9

Zonal Lumen Summary
Zone
0-30
0-40
0-60
0-90

Lumens
911.80
1737.18
3634.06
5883.18

% Lamp
9.6
18.3
38.3
61.9

% Fixture
15.5
29.5
61.8
100.0

Zone
90-120
90-130
90-150
90-180
0-180

Lumens
0.0
0.0
0.0
0.0
5883.18

% Lamp
0.0
0.0
0.0
0.0
61.9

% Fixture
0.0
0.0
0.0
0.0
100.0

REPORT NUMBER: CL10DD
Lamps: 100 W High Pressure Sodium with Deep Dome Reflector
Coefficients of Utilization - Zonal Cavity Method
Effective Floor Cavity Reflectance 0.20
% Ceiling Rcc
% Walls

Zone
0-10
10-20
20-30
30-40
40-50
50-60
60-70
70-80
80-90
90-100
100-110

50

70 50 30 10

Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

Rw
0
1
2
3
4
5
6
7
8
9
10

80

70

50

30

10

0

70 50 30 10

70 50 30 10

50 30 10

50 30 10

50 30 10

0

45
41
37
33
30
27
25
23
21
20
18

44
40
36
32
29
26
24
22
21
19
18

42
36
31
27
23
21
18
16
15
13
12

40
35
30
26
22
20
18
16
14
13
12

39
33
29
25
22
19
17
15
14
13
12

45
39
33
29
25
22
19
17
16
14
13

45
37
30
25
21
18
16
14
12
11
10

45
35
28
22
18
15
13
11
10
9
8

44
38
32
28
24
21
19
17
15
14
13

44
36
30
25
21
18
16
14
12
11
10

44
35
28
22
18
15
13
11
10
9
8

42
35
29
24
20
17
15
13
12
11
10

42
34
27
22
18
15
13
11
10
9
8

40
34
28
23
20
17
15
13
12
10
9

40
33
26
21
18
15
13
11
10
8
8

39
32
27
23
19
17
15
13
11
10
9

39
32
26
21
18
15
13
11
10
8
7

38
31
25
20
17
14
12
10
9
8
7

Zonal Lumen Summary
Zone
0-30
0-40
0-60
0-90

Lumens
687.82
1239.00
2639.18
3592.04

% Lamp
7.2
13.0
27.8
37.8

% Fixture
19.1
34.5
73.5
100.0

Zone
90-120
90-130
90-150
90-180
0-180

Lumens
0.0
0.0
0.0
0.0
3592.04

% Lamp
0.0
0.0
0.0
0.0
37.8

% Fixture
0.0
0.0
0.0
0.0
100.0

1227

Lighting: Explosionproof — Area — HID

Lumens
34.59
289.50
587.71
825.38
944.04
952.84
900.69
740.88
607.55
0.00
0.00

70

70 50 30 10

Lighting

Zone
0-10
10-20
20-30
30-40
40-50
50-60
60-70
70-80
80-90
90-100
100-110

Rw

80

Code•Master 2™ HID Factory Sealed Luminaire Photometric Data
Explosionproof, Dust-Ignitionproof

Integrally Ballasted. 50 W, 70 W, 100 W, 150 W, 250 W, 400 W HPS; 175 W, 250 W, 320 W, 350 W, 400 W PSMH; 175 W, 250 W, 400 W MH V.
Mogul Base. For use with threaded metal conduit.
* Photometric data is based on a 400-watt
clear Pulse Start Metal Halide lamp (34,000
lumens). For candlepower values of fixtures
with other lamps, use the following multipliers:
400 W HPS – 1.13 (50,000 lumens); and 250 W
HPS – 0.68 (30,000 lumens).
Total Luminaire Efficiency = 81.9%
CIE Type - General Diffuse

REPORT NUMBER: CP40G
Lamps: 400 W Pulse Start Metal Halide with Globe only
Coefficients of Utilization - Zonal Cavity Method
Effective Floor Cavity Reflectance 0.20
% Ceiling Rcc

Lighting: Explosionproof — Area — HID

Lighting

% Walls
Zone
0-10
10-20
20-30
30-40
40-50
50-60
60-70
70-80
80-90
90-100
100-110
110-120

Lumens
161.29
470.38
918.96
1511.24
2242.10
3052.29
3653.41
4255.87
4603.15
4476.83
4007.91
3380.83

120-130
130-140
140-150
150-160
160-170
170-180

2599.55
672.85
18.11
2.59
1.21
0.65

Total Luminaire Efficiency = 70.4%
CIE Type - Direct
Plane

Spacing
Criteria

0-180

1.46

90-270

1.46

Diagonal

1.70
Lumens
595.04
1709.44
2776.90
3730.18
4573.20
5290.95
5418.07
5086.12
1757.09
33.71
0.00
0.00

120-130

0.00

130-140
140-150
150-160
160-170
170-180

0.00
0.00
0.00
0.00
0.00

1228

70

50

30

10

0

Rw

70 50 30 10

70 50 30 10

50 30 10

50 30 10

50 30 10

0

0
1
2
3
4
5
6
7
8
9
10

89
76
67
60
55
50
45
42
39
36
33

83
70
62
55
50
45
41
38
35
33
31

72
55
45
39
33
29
26
23
21
19
18

61
46
37
32
27
24
21
19
17
16
15

52
38
30
25
22
19
17
15
14
13
12

89
70
59
50
43
38
34
30
27
25
22

89
65
51
42
35
30
26
22
20
18
16

89
60
45
36
29
24
20
17
15
13
11

83
65
54
46
40
35
31
28
25
23
21

83
60
48
39
32
28
24
21
18
16
15

83
56
42
33
27
22
18
16
14
12
10

72
51
40
33
27
23
20
18
15
14
12

72
48
36
28
23
19
16
13
12
10
9

61
43
33
27
22
19
16
14
13
11
10

61
40
30
23
19
15
13
11
9
8
7

52
35
27
22
18
15
13
11
10
9
8

52
33
24
19
15
12
10
9
7
6
6

47
29
20
15
12
9
8
6
5
5
4

Zonal Lumen Summary
Zone
0-30
0-40
0-60
0-90

Lumens
% Lamp
1550.63
3.5
3061.87
7.0
8356.25
19.0
20868.68
47.4

% Fixture
4.3
8.5
23.2
57.9

Zone
90-120
90-130
90-150
90-180
0-180

Lumens
11865.57
14465.12
15156.08
15160.53
36029.22

% Lamp
27.0
32.9
34.4
34.5
81.9

% Fixture
32.9
40.1
40.1
42.1
100.0

REPORT NUMBER: CP40ST
Lamps: 400 W Pulse Start Metal Halide with Standard Dome Reflector
Coefficients of Utilization - Zonal Cavity Method
Effective Floor Cavity Reflectance 0.20
% Ceiling Rcc
% Walls

Zone
0-10
10-20
20-30
30-40
40-50
50-60
60-70
70-80
80-90
90-100
100-110
110-120

80

80

70

50

30

10

0

Rw

70 50 30 10

70 50 30 10

50 30 10

50 30 10

50 30 10

0

0
1
2
3
4
5
6
7
8
9
10

84
74
65
58
53
48
44
41
38
35
33

82
72
63
57
51
46
43
39
37
34
32

78
64
54
46
40
35
31
28
26
23
22

75
62
51
44
38
34
30
27
25
23
21

72
59
49
42
36
32
29
26
24
22
20

84
69
58
49
43
38
33
30
27
25
23

84
65
52
42
35
30
26
23
21
18
17

84
62
47
37
30
25
21
18
16
14
13

82
68
57
48
42
37
33
29
27
24
22

82
64
51
42
35
30
26
23
20
18
17

82
60
46
36
30
25
21
18
16
14
13

78
61
49
40
34
29
25
22
20
18
16

78
58
45
36
29
24
21
18
16
14
13

75
59
47
39
33
28
25
22
19
18
16

75
57
44
35
29
24
21
18
16
14
12

72
57
46
38
32
27
24
21
19
17
16

72
55
43
34
28
24
20
18
15
14
12

70
53
41
32
26
22
19
16
14
12
11

Zonal Lumen Summary
Zone
0-30
0-40
0-60
0-90

Lumens
% Lamp
5081.38
11.5
8811.56
20.0
18675.71
42.4
30936.99
70.3

% Fixture
16.4
28.5
60.3
99.9

Zone
90-120
90-130
90-150
90-180
0-180

Lumens
33.71
33.71
33.71
33.71
30970.7

% Lamp
0.1
0.1
0.1
0.1
70.4

% Fixture
0.1
0.1
0.1
0.1
100.0

Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

Code•Master 2™ HID Factory Sealed Luminaire Photometric Data
Explosionproof, Dust-Ignitionproof

Integrally Ballasted. 50 W, 70 W, 100 W, 150 W, 250 W, 400 W HPS; 175 W, 250 W, 320 W, 350 W, 400 W PSMH; 175 W, 250 W, 400 W MH V.
Mogul Base. For use with threaded metal conduit.
* Photometric data is based on a 400-watt
clear Pulse Start Metal Halide lamp (34,000
lumens). For candlepower values of fixtures
with other lamps, use the following multipliers:
400 W HPS – 1.13 (50,000 lumens); and 250 W
HPS – 0.68 (30,000 lumens).
Total Luminaire Efficiency = 62.5%
CIE Type - Direct
Plane

Spacing
Criteria

0-180

2.02

90-270

1.48

Diagonal

1.64

REPORT NUMBER: CP40AN
Lamps: 400 W Pulse Start Metal Halide with 30° Angle Dome Reflector
Coefficients of Utilization - Zonal Cavity Method
Effective Floor Cavity Reflectance 0.20
% Ceiling Rcc
% Walls

120-130

65.68

130-140
140-150
150-160
160-170
170-180

20.81
11.94
7.93
4.46
1.47

Total Luminaire Efficiency = 69.1%
CIE Type - Direct
Plane

Spacing
Criteria

0-180

1.48

90-270

1.48

Diagonal

1.62
Lumens
676.92
1962.51
3199.12
4281.42
4889.12
5408.09
5456.18
3822.90
693.25
20.14
0.00
0.00

120-130
130-140
140-150
150-160
160-170
170-180

0.00
0.00
0.00
0.00
0.00
0.00

30

10

0

70 50 30 10

50 30 10

50 30 10

50 30 10

0

0
1
2
3
4
5
6
7
8
9
10

73
64
57
51
47
43
39
36
34
31
29

71
62
55
49
45
41
38
35
32
30
28

67
54
46
39
35
31
27
25
22
21
19

63
51
43
37
32
29
26
23
21
20
18

59
48
40
35
30
27
24
22
20
19
17

73
60
51
44
38
34
30
27
24
22
20

73
56
45
38
32
27
24
21
19
17
15

73
53
41
33
27
23
19
17
15
13
12

71
58
49
42
37
33
29
26
24
22
20

71
55
44
37
31
27
23
21
18
16
15

71
52
40
32
26
22
19
17
15
13
12

67
52
42
35
29
25
22
20
18
16
14

67
49
38
31
25
22
18
16
14
13
11

63
49
40
33
28
24
21
19
17
15
14

63
47
37
30
25
21
18
16
14
12
11

59
46
38
31
27
23
20
18
16
15
13

59
44
35
26
24
20
17
15
13
12
11

58
42
33
27
22
19
16
14
12
11
10

Zonal Lumen Summary
Zone
0-30
0-40
0-60
0-90

Lumens
% Lamp
4398.28
10.0
7751.71
17.6
15573.61
35.4
25338.08
57.6

% Fixture
16.0
28.2
56.7
92.2

Zone
90-120
90-130
90-150
90-180
0-180

Lumens
2039.87
2105.55
2138.30
2152.16
27490.24

% Lamp
4.6
4.8
4.9
4.9
62.5

% Fixture
7.4
7.7
7.7
7.8
100.0

REPORT NUMBER: CP40DD
Lamps: 400 W Pulse Start Metal Halide with Deep Dome Reflector
Coefficients of Utilization - Zonal Cavity Method
Effective Floor Cavity Reflectance 0.20
% Ceiling Rcc
% Walls

Zone
0-10
10-20
20-30
30-40
40-50
50-60
60-70
70-80
80-90
90-100
100-110
110-120

50

70 50 30 10

Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

80

70

50

30

10

0

Rw

70 50 30 10

70 50 30 10

50 30 10

50 30 10

50 30 10

0

0
1
2
3
4
5
6
7
8
9
10

82
74
66
59
54
49
45
41
38
36
34

80
72
64
57
52
47
44
40
37
35
33

77
65
55
48
42
37
33
30
27
25
23

73
63
53
46
40
35
32
29
26
24
22

70
60
51
44
38
34
30
28
25
23
21

82
70
59
51
44
39
35
31
28
26
24

82
66
54
44
38
32
28
24
22
20
18

82
63
49
39
32
27
23
20
18
16
14

80
68
58
50
43
38
34
31
28
25
23

80
65
53
44
37
32
28
24
22
20
18

80
62
49
39
32
27
23
20
18
16
14

77
63
51
42
36
31
27
24
21
19
18

77
60
47
38
32
27
23
20
17
16
14

73
60
49
41
35
30
26
23
21
19
17

73
58
46
38
31
26
23
20
17
15
14

70
58
48
40
34
29
26
23
21
19
17

70
57
45
37
31
26
22
19
17
15
14

69
55
44
35
29
24
21
18
16
14
12

Zonal Lumen Summary
Zone
0-30
0-40
0-60
0-90

Lumens
% Lamp
5838.56
13.3
10119.98
23.0
20417.19
46.4
30389.51
69.1

% Fixture
19.2
33.3
67.1
99.9

Zone
90-120
90-130
90-150
90-180
0-180

Lumens
20.14
20.14
20.14
20.14
30409.65

% Lamp
0.0
0.0
0.0
0.0
69.1

% Fixture
0.1
0.1
0.1
0.1
100.0

1229

Lighting: Explosionproof — Area — HID

Lumens
503.08
1461.14
2434.06
3353.43
3867.50
3954.40
3752.38
3368.71
2643.39
1531.50
421.63
86.74

70

Rw

Lighting

Zone
0-10
10-20
20-30
30-40
40-50
50-60
60-70
70-80
80-90
90-100
100-110
110-120

80

Code•Master 2™ HID Factory Sealed Luminaire Photometric Data
Explosionproof, Dust-Ignitionproof

Integrally Ballasted. 50 W, 70 W, 100 W, 150 W, 250 W, 400 W HPS; 175 W, 250 W, 320 W, 350 W, 400 W PSMH; 175 W, 250 W, 400 W MH V.
Mogul Base. For use with threaded metal conduit.
* Photometric data is based on a 400-watt
clear Pulse Start Metal Halide lamp (34,000
lumens). For candlepower values of fixtures
with other lamps, use the following multipliers:
400 W HPS – 1.13 (50,000 lumens); and 250 W
HPS – 0.68 (30,000 lumens).
Total Luminaire Efficiency = 63.4%
CIE Type - Direct
Plane

Spacing
Criteria

0-180

1.40

90-270

1.40

Diagonal

1.52

REPORT NUMBER: CP40HB
Lamps: 400 W Pulse Start Metal Halide with High Bay Reflector
Coefficients of Utilization - Zonal Cavity Method
Effective Floor Cavity Reflectance 0.20
% Ceiling Rcc
% Walls

Zone

Lighting: Explosionproof — Area — HID

Lighting

0-10

Rw

80

70

50

30

10

0

70 50 30 10

70 50 30 10

50 30 10

50 30 10

50 30 10

0

Lumens

0

76 76 76 76 74 74 74 74 70 70 70 67 67 67 65 65 65 63

1044.42

1

71 69 67 65 69 67 65 64 65 63 62 62 61 60 60 59 58 57

10-20

3491.70

2

66 62 59 56 64 61 58 55 59 56 54 57 55 53 55 53 52 50

20-30

5976.88

3

61 56 52 48 60 55 51 48 53 50 47 51 49 46 50 48 46 44

30-40

6632.58

4

57 50 46 42 55 50 45 42 48 44 42 47 44 41 45 43 40 39

40-50

7143.25

5

53 46 41 37 51 45 40 37 44 40 37 43 39 36 42 38 36 35

50-60

2844.46

6

49 42 37 33 48 41 36 33 40 36 33 39 35 32 38 35 32 31

60-70

634.65

7

46 38 33 30 44 37 33 29 37 32 29 36 32 29 35 31 29 28

70-80

115.54

8

42 35 30 27 42 34 30 26 34 29 26 33 29 26 32 29 26 25

80-90

20.82

9

40 32 27 24 39 32 27 24 31 27 24 30 26 24 30 26 24 23

10

37 29 25 22 36 29 25 22 29 24 22 28 24 22 27 24 21 20

90-100

1.23

100-110

0.00

110-120

0.00

Zonal Lumen Summary

120-130

0.00

Zone

Lumens

% Lamp

130-140

0.00

0-30

10513.00

23.9

37.7

90-120

1.23

0.0

0.0

140-150

0.00

0-40

17145.58

39.0

61.4

90-130

1.23

0.0

0.0

150-160

0.00

0-60

27133.29

61.7

97.2

90-150

1.23

0.0

0.0

160-170

0.00

0-90

27904.30

63.4

100.0

90-180

1.23

0.0

0.0

170-180

0.00

27905.53

63.4

100.0

1230

% Fixture

Zone

0-180

Lumens

% Lamp

% Fixture

Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

Code•Master 2™ Induction Lighting System
Explosionproof, Factory Sealed
Class I, Division 1 and 2, Groups C, D
Class II, Division 1 and 2, Groups E, F, G
Marine Type Electric Fixtures
Outside Type (Salt Water)
NEMA 4X

Applications
•	 Ideal for where access to relamp is difficult, reliability is
essential and environment is costly to maintain. Also for 	
cold-environment applications.
•	 Code Master Induction fixtures are ideal for: use in chemical
and petrochemical plants, such as manufacturers of plastics,
paints and thinners; in refineries; and in other process areas
where ignitable vapors, moisture and corrosive elements 	
may be present.
•	 Suitable for use in wet locations.

Features
•	
•	
•	
•	
•	
•	
•	
•	
•	

•	
•	
•	

•	
•	
•	

•	

Standard Materials
•	 Fixture bodies and guards: copperfree (4/10 of 1% max.)
aluminum.
•	 Pendant mounting hoods: diecast copperfree (4/10 of 1% max.)
aluminum.
•	 Ceiling, bracket and stanchion mounting hoods: sand-cast
copperfree (4/10 of 1% max.) aluminum.
•	 Reflectors: aluminum or fiberglass reinforced polyester.

Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

Standard Finishes
•	 Fixture bodies, guards and mounting hoods: epoxy powder 	
coat finish, electrostatically applied for complete, uniform
corrosion protection.

Options
•	 Fuses can be ordered for field installation by catalog number.

Certifications and Compliances
•	 UL Standard: UL 1598, UL 1598A, UL 844
•	 UL Listed: E10444

1231

Lighting: Explosionproof — Area — Induction

•	
•	
•	

Illustrated Features

Lighting

•	

Instant start and restrike.
High lumen output and efficacy (up to 73 lumens per watt).
Fixtures operate safely in a 104 °F/40 °C ambient.
Good lumen maintenance provides less than 30% depreciation
after 60,000 hours of operation.
Virtually maintenance free.
Ultra-long 100,000 hours of life keeps maintenance costs 	
to a minimum.
Starts in temperatures as low as -40 °F/-40 °C.
Arrangement of heat-producing components results in more
efficient heat dissipation for cooler fixture operation.
Patented “wireless” design. Threading of fixture unit onto
mounting hood makes electrical connection. Only wiring
required is attaching two wires to connection block in 	
mounting hood.
Connection block is easily wired: (a) loosen two screws; (b)
make wire connections; and (c) reposition connection block 	
and tighten screws.
Low total harmonic distortion (<10%).
No cycling at end of life.
Acme double lead threads speed installation and fixture
removal from mounting hood – only half as many turns are
required as for single lead threads. The threads do not stick or
gall, eliminating the troublesome problems often encountered
with single lead threads during fixture unit removal.
All threaded joints are flame-tight.
Factory sealed. External seals not required.
Strategic location of lamp socket in combination with the
interior prism design of the glass globe, provides optimum light
distribution and control.
Superior corrosion resistance, with epoxy powder coat finish.
Choice of mountings: pendant, ceiling, bracket or stanchion.
Fiberglass-reinforced polyester reflectors, in standard
dome, deep dome or 30° angle, are ideal in installations
where luminaire is subject to exceptionally severe corrosive
atmospheres. The high bay aluminum reflector is designed 	
for installations where mounting height work planes range 	
from 20 to 30 feet/6 to 9 meters
Optional guards protect globes from damage. Secured to
fixture with three screws.

Code•Master 2™ Induction Lighting System Classified Area and Ambient Suitability
Explosionproof, Factory Sealed
Class I, Division 1 and 2, Groups C, D
Class II, Division 1 and 2, Groups E, F, G
Marine Type Electric Fixtures
Outside Type (Salt Water)
NEMA 4X

Classified Area Suitability of Code•Master 2 Series Induction Fixtures (suitability includes use of reflector)

Induction

Class II, Division 1 & 2
With Globe or with Globe & Reflector
NEC/cUL/CEC Temp. Ident. No.

Watts

Supply Wire
Temp
°F/°C

Ambient
Temp
°F/°C

Nameplate Marking

Groups

Nameplate Marking

Groups

55

140/60

104/40

T6

C,D

T6

E,F,G

85

167/75

104/40

T6

C,D

T6

E,F,G

Lamps
Type

Class I, Division 1 & 2
With Globe or with Globe & Reflector
NEC/cUL/CEC Temp. Ident. No.

NOTE: The maximum operating temperature of the fixture must not exceed the ignition temperature of the gas, vapor or dust to be encountered per the
National Electrical Code.

“T”
Number

T1

350

325

T2

T2A

T2B

T2C

T2D

T3

T3A

T3B

T3C

T4

T4A

T5

T6

Temp.
Range
(°F)

664842

619662

574617

538572

502536

448500

421446

394419

358392

331356

322329

277320

250275

214248

187212

185

Temp.
Range
(°˚C)

351450

326350

301325

281300

261280

231260

216230

201215

181200

166180

161165

136160

121135

101120

86-100

85

Lighting: Explosionproof — Area — Induction

Lighting

“T” Numbers Represent the Maximum Surface Temperature for Class I, Division 1 Locations and
Maximum Surface Temperature Under Dust Blanket for Class II, Division 1 Locations.

1232

Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

Code•Master 2™ Induction Lighting System
Explosionproof, Factory Sealed
55 W and 85 W

Class I, Division 1 and 2, Groups C, D
Class II, Division 1 and 2, Groups E, F, G
Marine Type Electric Fixtures
Outside Type (Salt Water)
NEMA 4X

Type
Mounting

Lamp
Watts

Hub Size
(Inches)

Catalog
Number ➊

55

3/4

CQP5575 ➋

55

1

CQP5510 ➋

85

3/4

CQP8575 ➋

85

1

CQP8510 ➋

55

3/4

CQC5575 ➋

55

1

CQC5510 ➋

85

3/4

CQC8575 ➋

85

1

CQC8510 ➋

55

3/4

CQB5575 ➋

55

1

CQB5510 ➋

85

3/4

CQB8575 ➋

85

1

CQB8510 ➋

55

1-1/4 or 1-1/2 ➌

CQS55150 ➋

85

1-1/4 or 1-1/2 ➌

CQS85150 ➋

Pendant
One Hub, 	
Rigid or Flexible
Mounting

Ceiling
Four Hubs, 	
Three Close-up Plugs

Lighting

Bracket
Four Hubs, 	
Three Close-up Plugs

Lighting: Explosionproof — Area — Induction

25° Stanchion ➍
One Hub

  
➊ To order fixture with guard, add suffix G (before adding voltage suffix).
➋ Add voltage suffix 120 for 90-140 Vac; or 277 for 180-305 Vac.
➌ 1-1/2” tapped hub furnished with 1-1/2” to 1-1/4” reducer.
➍ Refer to lamp manufacturer’s data regarding lamp burning position restrictions.
Shaded items are suitable for Class I, Group C in addition to other applicable area suitabilities.
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

1233

Code•Master 2™ Induction Lighting System Accessories
Explosionproof, Factory Sealed
Class I, Division 1 and 2, Groups C, D
Class II, Division 1 and 2, Groups E, F, G
Marine Type Electric Fixtures
Outside Type (Salt Water)
NEMA 4X

Mounting Hoods
Hub Size
(Inches)

Type Mounting

Catalog Number

Pendant
3/4

CAP-75

1

CAP-100

Four Hubs,
Three Close-Up Plugs

3/4

CAC-75

1

CAC-100

Four Hubs,
Three Close-Up Plugs

3/4

CALB-75

1

CALB-100

One Hub

Ceiling

Bracket

25˚ Stanchion

Lighting: Explosionproof — Area — Induction

Lighting

One Hub

CAS-150

1-1/4 or 1-1/2 ➊

Mounting Adapter with Connection Block
Permits use of existing A-51 mounting hoods (AAC Ceiling or AALB
Bracket) with the new Code•Master 2 Fixture Unit. After removing
existing Fixture Unit and adapter, screw in the new CMAD-1 Adapter.
Then thread new Fixture Unit into the CMAD-1.

CMAD-1

Fixture Units — 55 W to 85 W
Fixture body with globe. Indicate voltage desired by adding voltage suffix to Fixture Unit catalog
number listed below.

Type

Frequency

120 V

277 V

Induction

50/60 Hz

55

CMBQ55

-12

-27

50/60 Hz

85

CMBQ85

-12

-27

Fixture and Accessory Weights lbs/kgs

Fixture Unit
Number

Add Voltage Suffixes

Lamp
Watts

Mounting Hood Weights lbs/kgs

Fixture Size

Fixture Weight

Reflector
Weight

Guard
Weight

55 W

28/12.7

3/1.4

1/.5

Pendant

Ceiling

Bracket

Stanchion

2/.9

4/1.8

6/2.7

2/.9

85 W

28/12.7

3/1.4

1/.5

➊ 1-1/2” Tapped hub furnished with 1-1/2” to 1-1/4” reducer.
Shaded items are suitable for Class I, Group C in addition to other applicable area suitabilities.

1234

Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

Code•Master 2™ Induction Lighting System Accessories
Explosionproof, Factory Sealed

Description

Catalog Number

Polyester Reflectors — 55 W and 85 W
Standard Dome

CMR-4ST

Deep Dome

CMR-4DD

30˚ Angle

CMR-4AN

55 W and 85 W

CMR-4HB

55 W and 85 W

CGL-400

Aluminum High Bay Reflectors

Prismatic Glass Globes

Lighting

Aluminum Guards
CGU4

Lighting: Explosionproof — Area — Induction

Connection Block
VPT-7

55 W and 85 W
For all Code•Master 2 Induction fixtures

Lamp
Watts

Volts

Fuse Quantity Required

Fuse Catalog Number

55

120-277

See note below ➊

CF2

85

120-277

See note below ➊

CF2

Fuse Kit includes fuse, fuse holder and necessary hardware for field installation. Mounts easily in ballast body with one screw.
➊ Order one fuse for 120 and 277 V, and 2 fuses for 208 and 240 V.
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

1235

Code•Master 2™ Induction Lighting System Operating Data
Explosionproof, Factory Sealed

Electromagnetic Compatibility
A.) Complies with European norms EN55015, EN6100-3-2 and EN61547
B.) RFI
a.) Meets standard EN55022 and is valid for frequencies up to 1000 MHz.

Lighting: Explosionproof — Area — Induction

Lighting

Electrical Characteristics

System power ➊ nom.
System power ➊ min.
System power ➊ max.
AC supply voltage nom.
AC supply voltage min.
AC supply voltage max.
DC supply voltage nom.
DC supply voltage min.
DC supply voltage max.
Supply frequency nom.
Supply frequency min.
Supply frequency max.
Supply current nom.
Inrush current max.
Duration inrush current max.
Power factor nom.
HF output frequency nom.
HF output frequency min.
HF output frequency max.
HF output voltage max.
Leakage current
Overvoltage

55 W
100-120 V
55
53.1
56.9
120
90
140
120
90
180
60
47
63
460
16
170
>0.92
2.65
2.30
3.00
1.5
<0.5
200 Vac

W
W
W
V
V
V
V
V
V
Hz
Hz
Hz
mA
A
usec
MHz
MHz
MHz
kV
mA

55 W
200-277 V
55
53.1
56.9
230
180
305
230
180
350
50
47
63
260
12
170
>0.92
2.65
2.30
3.00
1.5
<0.5
400 Vac

85 W
100-120 V
85
82.0
88.0
120
90
140
120
90
180
60
47
63
730
16
170
>0.92
2.65
2.30
3.00
1.5
<0.5
200 Vac

85 W
200-277 V
85
82.0
88.0
230
180
305
230
180
350
50
47
63
400
12
170
>0.92
2.65
2.30
3.00
1.5
<0.5
400 Vac

Lamp Characteristics
Values at 100 hours
Luminous flux nom.
Luminous flux min.
Luminous flux max.
System efficacy nom.

lm
lm
lm
lm/W

QL 55 W

QL 85 W

3500
3200
3800
65

6000
5500
6500
70

Lamp Operation
A.) Ignition and Lifetime Performance
a.) Ignition time <0.5 second
     Hot Restrike time <0.5 second
b.) Induction lighting offers a direct, flicker-free ignition after switch-on, in both cold and hot conditions
B.) Lumen Maintenance
a.)The lumens of an induction lamp are expected to have depreciated after 60,000 hours to no less than 75% of the initial lumens

➊ At design voltage.

1236

Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

Code•Master 2™ Induction Lighting System Photometric Data
Explosionproof, Factory Sealed

Data based on fixtures with 85-watt lamp.
For candlepower values of fixtures with other
lamps, use the following multiplier: for 55 W
lamp – 0.59 (3,500 lumens).

Total Luminaire Efficiency = 71.6%

Report Number: CMBQL85
85-Watt Lamp with Globe only

CIE Type - Semi-Direct
Degree

Candela

Lumens

Coefficients of Utilization - Zonal Cavity Method
Effective Floor Cavity Reflectance (Rfc) = 0.20

0

301

5

304

29

% Ceiling Rc

15

318

91

% Walls

80

70

50

30

10

0

Rw 70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10

0

25

359

166

0 79 79 79 79 74 74 74 74 65 65 65 57 57 57 49 49 49 46

35

398

250

1 68 63 58 54 63 59   55 51 51 48 45 44 41 39 37 35 33 30

45

424

328

2 60 53 46 41 56 49 43 39 42 38 34 36 32 29 30 27 25 22

55

447

400

3 54 45 38 32 50 42 36   30 36 31 27 30 26 23 25 22 19 16

65

465

462

4 49 39 32 26 45 36 30   25 31 26 22 26 22 19 22 18 16 13

75

475

502

5 45 34 27 22 41 32 25   21 27 22 18 23 19 15 19 16 13 11

85

474

517

90

472

Zonal Lumen Summary
Zone

Lumens % Lamp % Fixture

468

510

440

464

0- 30

115
125
135
145
155
165
175
180

348
205
58
2
1
1
0
0

344
185
49
2
0
0
0

0- 40
0- 60
0- 90
90-120
90-130
90-150
90-180
0-180

287  

4.8

6.7

537
1265
2745
1318
1503
1553
1553
4298

8.9
21.1
45.7
22.0
25.0
25.9
25.9
71.6

12.5
29.4
63.9
30.6
35.0
36.1
36.1
100.0

Total Luminaire Efficiency = 62.9%

8

6

9

13 10

7

6

8

12

6

5

Rw 70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10

0

10 30 20 15 11 28 19 14   10 17 12

9

14 10

9

Lumens

Coefficients of Utilization - Zonal Cavity Method
Effective Floor Cavity Reflectance (Rfc) = 0.20

0

960

5

962

92

15

955

271

% Ceiling Rc
% Walls

80

70

50

30

10

0

25

942

436

0 75 75 75 75 73 73 73 73 69 69 69 66 66 66 63 63 63 62

35

903

566

1 67 64 61 58 66 63 60 57 60 58 55 57 55 54 55 53 52 50

45

834

647

2 61 55 50 46 59 54 49 46 51 48 44 49 46 43 47 44 42 41

55

764

683

3 55 48 42 38 53 46 41 37 44 40 36 43 39 36 41 38 35 33

65

611

600

4 50 42 36 31 48 41 35 31 39 34 30 37 33 30 36 32 29 28

75

325

346

5 45 37 31 26 44 36 30 26 35 30 26 33 29 25 32 28 25 24

89

85

76

90

14

6 42 33 27 23 40 32 27 22 31 26 22 30 25 22 29 25 22 20
Zonal Lumen Summary
Zone

95

10

11

105

8

10

0-30

115
125
135
145
155
165
175
180

11
11
6
1
1
0
1
0

10
9
5
1
0
0
0

0-40
0-60
0-90
90-120
90-130
90-150
90-180
0-180

7 39 30 24 20 37 29 23 20 28 23 19 27 22 19 26 22 19 18

Lumens % Lamp % Fixture

8 36 27 21 17 35 26 21 17 25 21 17 25 20 17 24 20 17 15

798

13.3

21.1

9 33 25 19 15 32 24 19 15 23 19 15 23 18 15 22 18 15 14

1364
2694
3729
31
40
46
46
3775

22.7
44.9
62.2
0.5
0.7
0.8
0.8
62.9

36.1
71.4
98.8
0.8
1.1
1.2
1.2
100.0

10 31 23 17 14 30 22 17 14 21 17 14 21 17 14 20 16 13 12

Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

1237

Lighting: Explosionproof — Area — Induction

Candela

8 35 25 18 14 32 23 17   13 20 15 11 17 13 10 14 11
9 32 22 16 12 30 21 15   11 18 13 10 15 11

Report Number: CMBQL85ST
85-Watt Lamp with Standard Dome Reflector

CIE Type - Direct
Degree

9
7

9

Lighting

95
105

6 41 30 23 19 38 28 22   17 24 19 15 21 16 13 17 14 11
7 38 27 21 16 35 25 19   15 22 17 13 19 14 11 16 12

Code•Master 2™ Induction Lighting System Photometric Data
Explosionproof, Factory Sealed

Data based on fixtures with 85-watt lamp.
For candlepower values of fixtures with other
lamps, use the following multiplier: for 55 W
lamp – 0.59 (3,500 lumens).

Total Luminaire Efficiency = 56.7%

Report Number: CMBQL85AN
85-Watt Lamp with 30° Angle Dome Polyester Reflector

CIE Type - Direct
Candela Distribution
0.0

Coefficients of Utilization - Zonal Cavity Method

45.0 90.0 135.0 180.0 Flux

Effective Floor Cavity Reflectance (Rfc) = 0.20
% Ceiling Rc

0 842 842 842 842 842
5 881 869 843 814 802

Lighting

70

50

30

10

Rw 70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10

0
0

15 956 920 835 764 738 239

0 67 67 67 67 65 65 65 65 61 61 61 58 58 58 55 55 55 54

25 1015 956 833 728 676 388

1 60 56 53 51 58 55 52 49 52 49 47 49 47 45 46 45 43 42

35 1044 969 822 612 473 494

2 54 48 44 40 52 47 43 39 44 41 38 42 39 37 40 37 35 34

45 1046 960 772 358 198 522

3 48 42 37 33 47 41 36 32 38 34 31 36 33 30 35 32 29 28

55 1030 945 595 137

52 498

4 44 37 31 27 43 36 31 27 34 30 26 32 28 25 31 27 25 23

65 1004 898 349

30

3 441

5 40 33 27 23 39 32 27 23 30 26 22 29 25 22 27 24 21 20

75 932 711 142

2

0 349

6 37 29 24 20 36 29 23 20 27 23 19 26 22 19 25 21 19 17

85 705 425

43

1

1 223

7 34 26 21 17 33 26 21 17 25 20 17 24 20 17 23 19 16 15

90 551 289

11

2

2

8 32 24 19 15 31 23 19 15 22 18 15 22 18 15 21 17 15 13

95 393 177

4

4

4 108

9 30 22 17 14 29 21 17 14 21 16 13 20 16 13 19 16 13 12

105 147

Lighting: Explosionproof — Area — Induction

% Walls

81

80

115

46

61

1

9

6

40

4

3

13

9

13

10 28 20 16 12 27 20 15 12 19 15 12 18 15 12 18 14 12 11
Zonal Lumen Summary

125

2

1

4

12

9

5

Zone

Lumens

135

0

1

2

4

3

2

0- 30

707  

% Lamp
11.8

% Fixture
20.8

145

0

1

1

1

1

1

0- 40

1201

20.0

35.3

155

0

1

2

2

1

1

0- 60

2221

37.0

65.3

165

0

1

1

1

0

0

0- 90

3233

53.9

95.0

175

1

1

1

1

0

0

90-120

160

2.7

4.7

180

1

1

1

1

1

90-130

165

2.8

4.9

90-150

168

2.8

4.9

90-180

169

2.8

5.0

0-180

3403

56.7

100.0

1238

Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

Code•Master 2™ Induction Lighting System Photometric Data
Data based on fixtures with 85-watt lamp.
For candlepower values of fixtures with other
lamps, use the following multiplier: for 55 W
lamp – 0.59 (3,500 lumens).

Total Luminaire Efficiency = 63.4%

Report Number: CMBQL85DD
85-Watt Lamp with Deep Dome Polyester Reflector

CIE Type - Direct
Degree

Candela

Lumens

Coefficients of Utilization - Zonal Cavity Method
Effective Floor Cavity Reflectance (Rfc) = 0.20

0

1110

5

1109

106

% Ceiling Rc

15

1108

313

% Walls

25

1073

495

0 75 75 75 75 74 74 74 74 70 70 70 67 67 67 64 64 64 63

35

990

620

1 69 66 63 60 67 64 62 59 61 59 57 59 57 55 56 55 54 52

80

70

50

30

10

0

Rw 70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10

0

45

877

679

2 62 57 52 49 60 56 52 48 53 50 47 51 48 46 49 47 45 43

55

788

700

3 56 50 44 40 55 48 44 40 46 42 39 45 41 38 43 40 37 36

65

562

552

4 51 44 38 33 50 43 37 33 41 36 33 39 35 32 38 34 32 30

75

226

245

5 47 39 33 28 46 38 32 28 36 32 28 35 31 28 34 30 27 26

85

48

55

90

12

6 43 35 29 25 42 34 28 24 33 28 24 32 27 24 31 27 24 22
Zonal Lumen Summary

7

8

7

8

115
125
135
145
155
165
175
180

10
11
6
1
1
0
1
0

10
9
5
1
0
0
0

Zone
0-30
0-40
0-60
0-90
90-120
90-130
90-150
90-180
0-180

Lumens % Lamp % Fixture
15.2

24

9 35 26 21 17 34 26 20 17 25 20 17 24 20 17 23 19 17 15

1535
2914
3766
27
35
40
41
3806

25.6
48.6
62.8
0.4
0.6
0.7
0.7
63.4

40.3
76.5
98.9
0.7
0.9
1.1
1.1
100.0

10 32 24 19 15 32 24 19 15 23 18 15 22 18 15 22 18 15 14

Total Luminaire Efficiency = 56.4%

Report Number: CMBQL85HB
85-Watt Lamp with High Bay Aluminum Reflector

CIE Type - Direct
Candela

Lumens

Coefficients of Utilization - Zonal Cavity Method
Effective Floor Cavity Reflectance (Rfc) = 0.20

0

2608

5

2578

244

% Ceiling Rc

15

2261

634

% Walls

80

70

50

30

10

0

Rw 70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10

0

25

1705

784

0 67 67 67 67 65 65 65 65 62 62 62 59 59 59 57 57 57 56

35

1237

774

1 63 61 60 58 62 60 59 57 58 56 55 55 54 54 53 53 52 51

45

770

588

2 59 56 53 51 58 55 52 50 53 51 49 51 49 48 49 48 47 46

55

241

228

3 55 51 48 45 54 50 47 45 49 46 44 47 45 43 46 44 42 41

65

66

69

4 52 47 43 40 51 46 43 40 45 42 39 43 41 39 42 40 38 37

75

15

17

5 49 43 39 36 48 42 39 36 41 38 36 40 37 35 39 37 35 34

85

3

4

90

2

6 46 40 36 33 45 39 35 33 38 35 32 37 34 32 36 34 32 31
Zonal Lumen Summary

7 43 37 33 30 42 36 32 30 35 32 30 35 32 29 34 31 29 28

95

5

5

Zone

105

10

10

0- 30

Lumens % Lamp % Fixture
1662  

27.7

49.1

9 38 32 28 25 37 31 28 25 31 27 25 30 27 25 30 27 25 24

115
125
135
145
155
165
175
180

13
12
7
1
0
0
1
1

13
11
5
0
0
0
0

0- 40
0- 60
0- 90
90-120
90-130
90-150
90-180
0-180

2435
3251
3340
29
40
46
46
3386

40.6
54.2
55.7
0.5
0.7
0.8
0.8
56.4

71.9
96.0
98.6
0.9
1.2
1.3
1.4
100.0

10 36 30 26 23 35 29 26 23 29 25 23 28 25 23 28 25 23 22

Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

8 40 34 30 27 40 34 30 27 33 30 27 32 29 27 32 29 27 26

1239

Lighting: Explosionproof — Area — Induction

Degree

8 37 28 23 19 36 28 23 19 27 22 19 26 22 19 25 21 18 17

915

Lighting

95
105

7 40 31 26 22 39 31 25 21 30 25 21 29 24 21 28 24 21 19

Code•Master™ PLT Factory Sealed Luminaires
Explosionproof, Dust-Ignitionproof

Integrally Ballasted. 26 W, 32 W, 42 W, 52 W, 64 W, 84 W Compact Fluorescent. For use with Threaded Metal Conduit.
NEC:
Class I, Division 1 and 2, Groups B, C, D
Class II, Division 1 and 2, Groups E, F, G
Class III
NEMA 4X
Suitable for use in wet locations

Exd IIB + H2
Suitable for use in wet locations

CEC: V
Class I, Division 1 and 2, Groups B, C, D
Class I, Zone 1 and 2, Groups IIB + H2 T6
Class II, Division 1 and 2, Groups E, F, G
Class III
CSA 4X

Applications
•	 For use in hazardous locations such as plants where plastics,
paints, thinners and petrochemicals are manufactured, and in
other areas where ignitable vapors, dust, moisture and corrosive
elements may be present.
•	 For use in areas where an instant-on white light is desired.
•	 Suitable for use in wet locations.
•	 Standard fixtures designed for 26 W, 32 W, 42 W, 52 W (two 26
W), 64 W (two 32 W), and 84 W (two 42 W) PLT lamps.
•	 Cold weather starting to a minimum temperature of 0 °F/	
-18 °C for the Code•Master Jr. PLT and -22 °F/-30 °C for the
Code•Master 2 PLT.

Lighting

Lighting: Explosionproof — Area — Fluorescent

Features
•	 Fixtures operate safely in high ambient temperatures.
•	 Arrangement of heat-producing components results in efficient
heat dissipation for cooler fixture operation.
•	 Patented “wireless” design. Threading of fixture unit onto
mounting hood makes electrical connection. The only 	
wiring required is attaching two wires to connection block 	
in mounting hood.
•	 Connection block is easily wired: (a) loosen two screws; (b)
make wire connections; and (c) reposition connection block.
•	 Safe, easy servicing without disconnecting any wiring.
“Wireless” fixture unit threads off mounting hood for convenient
servicing or for immediate replacement with a “stand-by” unit.
•	 Acme double-lead threads speed installation and fixture removal
from mounting hood – only half as many turns are required
as for single-lead threads. The threads do not stick, or gall,
eliminating problems often encountered with single-lead threads
during fixture unit removal.
•	 All threaded joints are flame-tight.
•	 Factory sealed. External seals not required for Groups C and D.
•	 Fixtures for use in Group B locations are furnished complete
with UL required sealing fitting for Code•Master Jr. PLT only.
•	 Heat- and impact-resistant globes have smooth 	
dust-resistant exterior.
•	 Superior corrosion resistance, with epoxy powder coat finish.
•	 Fluorescent light source reduces energy cost.
•	 Strategic location of lamp socket, in combination with interior
prism design of the glass globe, provides optimum light
distribution and control.
•	 Choice of mountings – pendant, ceiling, bracket and stanchion.
•	 Optional guards protect globes from damage. Secured to fixture
with three stainless steel screws.
•	 Fiberglass reinforced polyester reflectors, in standard dome
or 30° angle styles, are ideal in installations where luminaire is
subject to exceptionally severe corrosive atmospheres. The
high bay aluminum reflector is intended for installations where
mounting height work planes range from 20 to 30 feet/6 to 9
meters.
•	 Fluorescent lamp life of 10,000 hours reduces relamping cost
compared to incandescent, and pr •	
Ballast bodies
and guards: copperfree (4/10 of 1% max.) aluminum
•	 Pendant mounting hoods: diecast copperfree (4/10 of 1% max.)
aluminum
•	 Ceiling, bracket and stanchion mounting hoods: sand cast
copperfree (4/10 of 1% max.) aluminum
•	 Reflectors: fiberglass reinforced polyester (white) or 	
aluminum

26-42W Code•Master Jr. PLT

52-84W Code•Master 2 PLT
Illustrated Features
Mounting Hood

Collector Ring
and Pin

Connection Block
Double Lead
Acme Threads

As Fixture unit is threaded into mounting
hood an automatic electrical connection is made.

Standard Finishes
•	 Ballast bodies, guards and mounting hoods: epoxy powder 	
coat finish, electrostatically applied for complete, uniform
corrosion protection

Certifications and Compliances
•	 UL Standard: UL 1598, UL 844
•	 UL Listed: E10444

 Fixtures are for use with Group B atmospheres only when used with Group B mounting hoods. For 26 W,32 W, and 42 W fixtures only.
V CSA Certification only.

1240

Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

Code•Master™ PLT Factory Sealed Luminaires
Explosionproof, Dust-Ignitionproof

Integrally Ballasted. 26 W, 32 W, 42 W, 52 W, 64 W, 84 W Compact Fluorescent. For use with Threaded Metal Conduit.
NEC:
Class I, Division 1 and 2, Groups B, C, D
Class II, Division 1 and 2, Groups E, F, G
Class III
NEMA 4X
Suitable for use in wet locations

Exd IIB + H2
Suitable for use in wet locations

CEC: V
Class I, Division 1 and 2, Groups B, C, D
Class I, Zone 1 and 2, Groups IIB + H2 T6
Class II, Division 1 and 2, Groups E, F, G
Class III
CSA 4X

Catalog Numbering Guide
CJ

F

P

26

75

Mouning:
P - Pendant
C - Ceiling	
B - Bracket	
S - Stanchion
PB - Group B Pendant ◆
SB - Group B Stanchion ◆

Series:
CJ - Code•Master
Jr. ◆
C - Code•Master 2

Hub Size:
75 - 3/4”
10 - 1”
150 - 1-1/2” or 1-1/4”

Wattage:
26 - 26 Watts	
32 - 32 Watts	
42 - 42 Watts	
52 - 52 Watts
64 - 64 Watts	
84 - 84 Watts

BU

L

Voltage:
BU - 120-277 V 50/60 Hz
A5 - 347 V 60 Hz V

Guard:
G -  Guard provided
Blank -  Guard not provided

Options:
L - Lamps Provided
F - Fused
Z - Zone 1	
Exd IIB + H2 V

Classified Area Suitability of Code•Master™ Series PLT Fixtures — Suitability includes use of reflector

Lamp
Type
PLT
(4-pin)
PLT
(4-pin)
PLT
(4-pin)

Class I, Division 1 & 2 with Globe or
with Globe & Reflector
UL/NEC Temp. Ident. No.

Class II, Division 1 & 2 with Globe or
with Globe & Reflector
UL/NEC Temp. Ident. No.

Supply
Wire
°F/°C

Ambient
Temp
°F/°C

Nameplate
Marking

Groups

Nameplate
Marking

Groups

26

167/75

104/40

T6

B◆,C,D

T4A

E, F, G

32

167/75

104/40

T6

B◆,C,D

T4A

E, F, G

42

167/75

104/40

T6

B◆,C,D

T4A

E, F, G

167/75
167/75
167/75
167/75
167/75
167/75
167/75
167/75
167/75

104/40
131/55
149/65
104/40
131/55
149/65
104/40
131/55
149/65

T6
T5
T5
T6
T5
T5
T6
T5
T5

C, D
C, D
C, D
C, D
C, D
C, D
C, D
C, D
C, D

T4
—
—
T4
—
—
T4
—
—

E, F, G
—
—
E, F, G
—
—
E, F, G
—
—

PLT
(4-pin)

52
(2 x 26)

PLT
(4-pin)

64
(2 x 32)

PLT
(4-pin)

84
(2 x 42)

Lighting

Lamp
Watts

“T” Numbers Represent the Maximum Surface Temperature for Class I, Division 1 Locations and
Maximum Surface Temperature Under Dust Blanket for Class II, Division 1 Locations.
“T”
Number

T1

350

325

T2

T2A

T2B

T2C

T2D

T3

T3A

T3B

T3C

T4

T4A

T5

T6

Temp
Range
(°F)

664842

619662

574617

538572

502536

448500

421446

394419

358392

331356

322329

277320

250275

214248

187212

185

Temp.
Range
(°˚C)

351450

326350

301325

281300

261280

231260

216230

201215

181200

166180

161165

136160

121135

101120

86-100

85

 Fixtures are for use with Group B atmospheres only when used with Group B mounting hoods. For 26 W,32 W, and 42 W fixtures only.
V CSA Certification only.
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

Lighting: Explosionproof — Area — Fluorescent

Lamp Type:
F - Fluorescent

G

1241

Code•Master™ PLT Factory Sealed Luminaires
Explosionproof, Dust-Ignitionproof

Integrally Ballasted. 26 W, 32 W, 42 W, 52 W, 64 W, 84 W Compact Fluorescent. For use with Threaded Metal Conduit.
NEC:
Class I, Division 1 and 2, Groups B, C, D
Class II, Division 1 and 2, Groups E, F, G
Class III
NEMA 4X
Suitable for use in wet locations

Lamp
Watts

Hub Size
(Inches)

Catalog Number
with Globe ➊

26

3/4

CJFPB2675BU

32

3/4

CJFPB3275BU

42

3/4

CJFPB4275BU

26

1-1/2

CJFSB26150BU

32

1-1/2

CJFSB32150BU

42

1-1/2

CJFSB42150BU

25° Stanchion

One Hub

Mounting Hoods
Hub Size
Inches

Catalog
Number

3/4

CAP-75B

1-1/2

CAS-150B

Pendant — One Hub

Lighting

Lighting: Explosionproof — Area — Fluorescent

Pendant — One Hub, Rigid or Flexible Mounting

25° Stanchion — One Hub ➋

NOTE: Fixture units are the same as listed on following pages.
 Fixtures are for use with Group B atmospheres only when used with Group B mounting hoods. For 26 W,32 W, and 42 W fixtures only.
➊ To order fixture with guard, add suffix -G before adding voltage suffix.
➊ To order fixture with lamp(s), add suffix -L after voltage suffix.
➋ Malleable iron sealing fittings are available in the Fittings Section.

1242

Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

Code•Master™ PLT Factory Sealed Luminaires
Explosionproof, Dust-Ignitionproof

Integrally Ballasted. 26 W, 32 W, 42 W, 52 W, 64 W, 84 W Compact Fluorescent. For use with Threaded Metal Conduit.
NEC:
Class I, Division 1 and 2, Groups C, D
Class II, Division 1 and 2, Groups E, F, G
Class III
NEMA 4X
Suitable for use in wet locations

CEC: V
Class I, Division 1 and 2, Groups B, C, D
Class I, Zone 1 and 2, Groups IIB + H2 T6
Class II, Division 1 and 2, Groups E, F, G
Class III
CSA 4X

Lamp
Watts
Pendant — One Hub, Rigid or Flexible Mounting
26 (1 x 26)
32 (1 x 32)
42 (1 x 42)
52 (2 x 26)
64 (2 x 32)

26 (1 x 26)
32 (1 x 32)
42 (1 x 42)
52 (2 x 26)
64 (2 x 32)
84 (2 x 42)
52-84 W Shown
Bracket — Four Hubs, Three Close-Up Plugs
26 (1 x 26)
32 (1 x 32)
42 (1 x 42)

64 (2 x 32)
26-42 W Shown

84 (2 x 42)

25° Stanchion — One Hub
26 (1 x 26)
32 (1 x 32)
42 (1 x 42)
52 (2 x 26)
64 (2 x 32)
84 (2 x 42)

NEC/CEC V
Catalog Number
with Globe ➊➌

CEC V
Catalog Number
with Globe ➊➌

3/4
1
3/4
1
3/4
1
3/4
1
3/4
1
3/4
1

CJFP2675BU
CJFP2610BU
CJFP3275BU
CJFP3210BU
CJFP4275BU
CJFP4210BU
CFP5275BU
CFP5210BU
CFP6475BU
CFP6410BU
CFP8475BU
CFP8410BU

CJFP2675A5
CJFP2610A5
CJFP3275A5
CJFP3210A5
CJFP4275A5
CJFP4210A5
CFP5275A5
CFP5210A5
CFP6475A5
CFP6410A5
CFP8475A5
CFP8410A5

3/4
1
3/4
1
3/4
1
3/4
1
3/4
1
3/4
1

CJFC2675BU
CJFC2610BU
CJFC3275BU
CJFC3210BU
CJFC4275BU
CJFC4210BU
CFC5275BU
CFC5210BU
CFC6475BU
CFC6410BU
CFC8475BU
CFC8410BU

CJFC2675A5
CJFC2610A5
CJFC3275A5
CJFC3210A5
CJFC4275A5
CJFC4210A5
CFC5275A5
CFC5210A5
CFC6475A5
CFC6410A5
CFC8475A5
CFC8410A5

3/4
1
3/4
1
3/4
1
3/4
1
3/4
1
3/4
1

CJFB2675BU
CJFB2610BU
CJFB3275BU
CJFB3210BU
CJFB4275BU
CJFB4210BU
CFB5275BU
CFB5210BU
CFB6475BU
CFB6410BU
CFB8475BU
CFB8410BU

CJFB2675A5
CJFB2610A5
CJFB3275A5
CJFB3210A5
CJFB4275A5
CJFB4210A5
CFB5275A5
CFB5210A5
CFB6475A5
CFB6410A5
CFB8475A5
CFB8410A5

1-1/4 or 1-1/2 ➋
1-1/4 or 1-1/2 ➋
1-1/4 or 1-1/2 ➋
1-1/4 or 1-1/2 ➋
1-1/4 or 1-1/2 ➋
1-1/4 or 1-1/2 ➋

CJFS26150BU
CJFS32150BU
CJFS42150BU
CFS52150BU
CFS64150BU
CFS84150BU

CJFS26150A5
CJFS32150A5
CJFS42150A5
CFS52150A5
CFS64150A5
CFS84150A5

Lighting

52 (2 x 26)

Hub Size
(Inches)

Lighting: Explosionproof — Area — Fluorescent

84 (2 x 42)
26-42 W Shown
Ceiling — Four Hubs, Three Close-Up Plugs

Exd IIB + H2
Suitable for use in wet locations

52-84 W Shown
➊ To order fixture with guard, add suffix -G before adding voltage suffix. To order fixture with lamp(s), add suffix -L after voltage suffix.
➋ 1-1/2” tapped hub furnished with 1-1/2” to 1-1/4” reducer.
➌ BU is 120 through 277 V, 50/60 Hz and 125 Vdc. A5 is 347 V, 60 Hz V.
V CSA Certification only.
 Shaded items are suitable for Class I, Group D ONLY.
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

1243

Code•Master™ PLT Factory Sealed Luminaire Mounting Hoods and Fixture Units
Explosionproof, Dust-Ignitionproof

Integrally Ballasted. 26 W, 32 W, 42 W, 52 W, 64 W, 84 W Compact Fluorescent. For use with Threaded Metal Conduit.
NEC:
Class I, Division 1 and 2, Groups C, D
Class II, Division 1 and 2, Groups E, F, G
Class III
NEMA 4X
Suitable for use in wet locations

CEC: V
Class I, Division 1 and 2, Groups B, C, D
Class I, Zone 1 and 2, Groups IIB + H2 T6
Class II, Division 1 and 2, Groups E, F, G
Class III
CSA 4X

Exd IIB + H2
Suitable for use in wet locations

Mounting Hoods
Hub Size
(Inches)

Catalog
Number

Pendant
3/4

CAP-75

1

CAP-100

3/4

CAC-75

1

CAC-100

3/4

CALB-75

1

CALB-100

1-1/4 or 1-1/2 ➊

CAS-150 ➊

Lighting: Explosionproof — Area — Fluorescent

Ceiling

Bracket

25° Stanchion

Mounting Adapter with Connection Block
CMAD-1
Fixture Units
Line
Voltage

Hz

Catalog
Number

120-277

50/60

CJB26FBU ➋

120-277

50/60

CJB32FBU ➋

120-277

50/60

CJB42FBU ➋

120-277

50/60

CMBF52BU

120-277

50/60

CMBF64BU

120-277

50/60

CMBF84BU

Lighting

Ballast body with globe

26-42 W

52-84 W

Electrical Specification
Lamp Wattage

Line Voltage

Frequency (Hz)

Line Amps

Input Watts

Min. Starting Temp

26 (1 x 26)

120-277

50/60

0.25-0.11

28

0 °F/-18 °C

32 (1 x 32)

120-277

50/60

0.27-0.12

36

0 °F/-18 °C

42 (1 x 42)

120-277

50/60

0.35-0.16

48

0 °F/-18 °C

52 (2 x 26)

120-277

50/60

0.49-0.20

55

-22 °F/-30 °C

64 (2 x 32)

120-277

50/60

0.57-0.24

67

-22 °F/-30 °C

84 (2 x 42)

120-277

50/60

0.73-0.31

87

-22 °F/-30 °C

➊ 1-1/2” tapped hub furnished with 1-1/2” to 1-1/4” reducer.
➋ Denotes items that are suitable for Class I, Group B in addition to Class I, Groups C and D; and Class II, Groups E, F and G.
V CSA Certification only.
 Shaded items are suitable for Class I, Group C in addition to Class I, Group D; Class II, Groups E, F and G; and Class III.

1244

Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

Code•Master™ PLT Factory Sealed Luminaire Accessories
Explosionproof, Dust-Ignitionproof

Integrally Ballasted. 26 W, 32 W, 42 W, 52 W, 64 W, 84 W Compact Fluorescent. For use with Threaded Metal Conduit.

Catalog
Number

Description
White Polyester Reflectors

Furnished with stainless steel screws
For Globe Fixtures

Standard Dome

30° Angle Dome

Standard Dome

26, 32, 42 W

KR2-ST

30°Angle

26, 32, 42 W

KR2-AN

Standard Dome

52, 64, 84 W

CMR-4ST

30°Angle

52, 64, 84 W

CMR-4AN

Deep Dome

52, 64, 84 W

CMR-4DD

High Bay

52, 64, 84 W

CMR-4HB

Aluminum Reflectors

Lighting: Explosionproof — Area — Fluorescent

Prismatic Glass Globe and Ring Assembly

CJGL-175

26, 32, 42 W

CJGL-175

52, 64, 84 W

CGL-400

26, 32, 42 W

CJGU-15

52, 64, 84 W

CGU-4

CGL-400

Aluminum Guards

CJGU-15

CGU-4
Lighting

Three-Way Exit Sign
Epoxy enameled steel — 6”-high red lettering
Mounts to fixture units in place of guard.
26, 32, 42 W

CJEXRN

52, 64, 84 W

EXR400

Single Sided Exit Sign
Epoxy enameled steel — 6”-high red lettering
Mounts to fixture units in place of guard.

Contact your sales representative regarding hazardous location suitability.

26, 32, 42 W

Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

AEXR-15R

1245

Code•Master™ PLT Factory Sealed Luminaire Accessories
Explosionproof, Dust-Ignitionproof

Integrally Ballasted. 26 W, 32 W, 42 W, 52 W, 64 W, 84 W Compact Fluorescent. For use with Threaded Metal Conduit.

Description

Catalog Number

Replacement Parts – 26 W, 32 W, 42 W, 52 W, 64 W and 84 W

Lighting: Explosionproof — Area — Fluorescent

PLT32RS

CJSA42

Socket (lampholder) G24Q-4

26 thru 84 W

PLT32RS

Single Socket Bracket Assembly

26, 32, 42 W

CJSA42

Double Socket Bracket Assembly

52, 64, 84 W

CSA84

1 lamp = 26 W; 2 lamps = 52 W

26 W

PLT26

1 lamp = 32 W; 2 lamps = 64 W

32 W

PLT32

1 lamp = 42 W; 2 lamps = 84 W

42 W

PLT42

26, 32, 42 W

59661256001

52, 64, 84 W

59661259001

CSA84
Lamps

Replacement Ballast

Connection Block
VPT-7

Lighting

For all Code•Master fixtures

Fixture and Accessory Weights lbs/kgs

Mounting Hood Weights lbs/kgs

Fixture Size

Fixture Weight

Reflector Weight

Guard Weight

Pendant

Ceiling

Bracket

Stanchion

26 W, 32 W, 42 W

14.5/6.6

3.0/1.4

1.0/0.5

2/0.9

4/1.8

6/2.7

2/0.9

52 W, 64 W, 84 W

35.0/15.9

3.0/1.4

2.5/1.1

Reflector Dimensions
Catalog
Number

Description

Standard Dome
KR2-ST
26, 32, 42 W
CMR-4ST
52, 64, 84 W
Deep Dome
CMR-4DD
52, 64, 84 W
30° Angle
KR2-AN
26, 32, 42 W
CMR-4AN
52, 64, 84 W

1246

A

Dimensions in In/mm
B
C

D

Standard and Deep Dome

30° Angle

A

8.00/203.2
11.20/284.5

6.00/152.4
5.90/149.9

16.90/429.3
18.70/475.0

—
—

10.56/268.2

7.00/177.8

20.30/515.6

—

A

B

B

D
C

8.00/203.2
10.56/268.2

2.75/69.9
5.00/127

14.90/378.5
16.16/410.5

10.17/258.3
9.75/247.7

C

Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

Code•Master™ PLT Factory Sealed Luminaire Dimensions
Explosionproof, Dust-Ignitionproof

Integrally Ballasted. 26 W, 32 W, 42 W, 52 W, 64 W, 84 W Compact Fluorescent. For use with Threaded Metal Conduit.

Mounting Hoods
Pendant

Ceiling

Bracket

4.00"/
101.6 mm

9.86"/
250.4 mm

4.00"/
101.6 mm

17.61"/
447.3 mm

4.25"/
108.0 mm

4.92"/125.0 mm Sq.
4.50"/
114.3 mm

20.50"/
520.7 mm

9.50"/
241.3 mm
6.10"/
155.0 mm

2.46"/
2.28"/
62.9 mm 57.9 mm

3.91"/99.3 mm

21.50"/
546.1 mm

25° Stanchion

1.23"/
31.2 mm
3.48"/
88.4 mm

3.92"/
99.6 mm

5.92"/
150.4 mm

1.79"/
45.7 mm

2.38"/
60.5 mm
Dia.

4.50"/
114.3 mm
Dia.

11.5"/
292.1 mm
13.75"/
349.3 mm

12.00"/
304.8 mm

26, 32, 42 W Fixture

17.87"/
453.9 mm

16.00"/
406.4 mm
16.88"/
428.8 mm

17.47"/
443.7 mm

7.40"/
188.0 mm

18.12"/
460.2 mm

7.40"/
188.0 mm

14.12"/
358.6 mm

14.12"/
358.6 mm

16.25"/
412.8 mm

16.00"/
406.4 mm

8.00"/
203.2 mm

8.00"/
203.2 mm

15.62"/
396.7 mm
16.25"/
412.8 mm

4.00"/
101.6 mm

3.75"/95.3 mm

7.40"/
188.0 mm

17.22"/
437.9 mm

23.61"/
599.7 mm
24.61"/
625.1 mm
20.36"/
517.1 mm

9.86"/
250.4 mm
20.36"/
517.1 mm

17.5"/
444.5 mm

12.0"/
304.8 mm
12.0"/
304.8 mm

Lighting

20.36"/
517.1 mm

9.86"/
250.4 mm

24.36"/
618.7 mm

9.86"/
250.4 mm

23.36"/
593.3 mm

23.5"/
596.9 mm
24.5"/
622.3 mm

3.91"/
99.3 mm

21.2"/
538.5 mm
22.2"/
563.9 mm

52, 64, 84 W Fixture

5.5"/
139.7 mm

17.5"/
444.5 mm

Exit Signs

9.25"/
235.0 mm

6.88"/
174.8 mm
11.75"/298.5 mm

12.00"/
304.8 mm

CJEXRN

Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

Lighting: Explosionproof — Area — Fluorescent

0.94"/
23.9 mm

4.58"/
116.3 mm
Dia.

8.50"/
215.9 mm

AEXR-15R

1247

Code•Master™ PLT Factory Sealed Luminaire Photometric Data
Explosionproof, Dust-Ignitionproof

Integrally Ballasted. 26 W, 32 W, 42 W, 52 W, 64 W, 84 W Compact Fluorescent. For use with Threaded Metal Conduit.
* Photometric data is based on a fixture with
a 32 W compact fluorescent PL-T lamp (2,400
lumens). For candlepower values of fixtures
with 26 W PL-T lamps (1,800 lumens), multiply by
0.75. For candlepower values of fixtures with a
42 W PL-T Lamp (3,200 lumens), multiply by 1.34.
Total Luminaire Efficiency = 92.9%
CIE Type - Semi-Direct
Plane

Spacing
Criteria

0-180

2.76

90-270

2.76

Diagonal

2.72

REPORT NUMBER: CJBF32G
32 W Fluorescent Lamp with Globe only *
Coefficients of Utilization - Zonal Cavity Method
Effective Floor Cavity Reflectance 0.20
% Ceiling Rcc

Lighting: Explosionproof — Area — Fluorescent

% Walls
Zone
0-10
10-20
20-30
30-40
40-50
50-60
60-70
70-80
80-90
90-100
100-110

Lumens
9.75
32.89
68.63
119.65
174.44
219.68
252.32
278.38
283.11
266.38
231.16

110-120

166.66

120-130
130-140
140-150
150-160
160-170
170-180

91.63
31.38
2.95
0.19
0.00
0.00

0
1
2
3
4
5
6
7
8
9
10

Maximum Candela = 265
Located at Horizontal Angle = 0, Vertical Angle = 77.5
#1 - Vertical Plane through Horizontal Angles (0-180)
(Through Max. Cd.)
#2 - Horizontal Cone through Vertical Angle (77.5)
(Through Max. Cd.)

CIE Type - Direct

Lighting

Plane

Spacing
Criteria
1.42

90-270

1.42

Diagonal

1.60

Zone
0-30
0-40
0-60
0-90

110-120

6.82
5.50
3.07
0.09
0.00
0.00
0.00

1248

30

10

0

30

10

70

50

30

10

50

30

10

50

30

10

50

30

10

0

103
88
78
69
63
57
52
48
44
41
38

103
81
67
57
50
43
38
34
31
28
25

103
75
59
48
40
34
29
25
22
20
18

103
70
52
41
33
27
23
19
17
14
13

97
82
72
64
58
52
48
44
41
38
35

97
76
63
53
46
40
36
32
29
26
24

97
70
55
45
37
32
27
24
21
19
17

97
65
49
38
31
25
21
18
16
14
12

85
65
54
46
39
35
31
27
25
23
21

85
61
48
39
32
27
24
21
18
16
15

85
57
43
33
27
22
18
16
14
12
10

74
56
46
39
33
29
26
23
21
19
18

74
53
41
33
28
23
20
18
16
14
12

74
50
37
29
23
19
16
13
11
10
9

65
48
38
32
28
24
21
19
18
16
15

65
45
35
28
23
19
17
15
13
12
10

65
42
31
24
19
16
13
11
9
8
7

60
38
27
20
16
13
10
9
7
6
5

Lumens
111.27
230.92
625.05
1438.87

% Lamp
4.6
9.6
26.0
60.0

% Fixture
5.0
10.4
28.0
64.5

Zone
90-120
90-130
90-150
90-180
0-180

Lumens
664.20
755.83
790.17
790.36
2229.23

% Lamp
27.7
31.5
32.9
32.9
92.9

% Fixture
29.8
33.9
33.9
35.5
100.0

Coefficients of Utilization - Zonal Cavity Method
Effective Floor Cavity Reflectance 0.20
% Ceiling Rcc

Lumens
51.88
151.03
240.04
312.02
361.09
377.88
278.20
119.22
23.81
0.68
4.48

120-130
130-140
140-150
150-160
160-170
170-180

50

50

REPORT NUMBER: CJBF32ST
32 W Fluorescent Lamp with Globe and Standard Dome Reflector *

% Walls
Zone
0-10
10-20
20-30
30-40
40-50
50-60
60-70
70-80
80-90
90-100
100-110

70

70

Zonal Lumen Summary

Total Luminaire Efficiency = 80.7%

0-180

Rw

80

Rw
0
1
2
3
4
5
6
7
8
9
10

80

70

50

30

10

0

70

50

30

10

70

50

30

10

50

30

10

50

30

10

50

30

10

0

96
87
79
72
65
60
55
51
47
44
41

96
84
72
63
55
49
44
39
36
33
30

96
80
67
56
48
41
36
32
29
26
23

96
77
62
51
42
36
31
27
24
21
19

93
85
77
70
63
58
53
49
46
43
40

93
82
71
62
54
48
43
39
35
32
30

93
78
66
55
47
41
36
32
28
26
23

93
76
61
50
42
36
31
27
24
21
19

89
78
68
59
52
46
41
37
34
31
29

89
75
63
54
46
40
35
31
28
25
23

89
73
60
49
41
35
30
27
23
21
19

85
75
65
57
50
44
40
36
33
30
28

85
73
61
52
45
39
34
30
27
25
23

85
71
58
48
41
35
30
26
23
21
19

82
72
62
54
48
43
39
35
32
29
27

82
70
59
51
44
38
34
30
27
24
22

82
68
57
47
40
34
30
26
23
21
19

80
67
55
45
38
32
28
24
21
19
17

Zonal Lumen Summary
Maximum Candela = 545
Located at Horizontal Angle = 0, Vertical Angle = 5
#1 - Vertical Plane through Horizontal Angles (0-180)
(Through Max. Cd.)
#2 - Horizontal Cone through Vertical Angle (5)
(Through Max. Cd.)

Zone
0-30
0-40
0-60
0-90

Lumens
442.95
754.97
1493.95
1915.18

% Lamp
18.5
31.5
62.2
79.8

% Fixture
22.9
39.0
77.2
98.9

Zone
90-120
90-130
90-150
90-180
0-180

Lumens
11.98
17.48
20.63
20.63
1935.81

% Lamp
0.5
0.7
0.9
0.9
80.7

% Fixture
0.6
0.9
0.9
1.1
100.0

Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

Code•Master™ PLT Factory Sealed Luminaire Photometric Data
Explosionproof, Dust-Ignitionproof

Integrally Ballasted. 26 W, 32 W, 42 W, 52 W, 64 W, 84 W Compact Fluorescent. For use with Threaded Metal Conduit.
* Photometric data is based on a fixture with
a 32 W compact fluorescent PL-T lamp (2,400
lumens). For candlepower values of fixtures
with 26 W PL-T lamps (1,800 lumens), multiply by
0.75. For candlepower values of fixtures with a
42 W PL-T Lamp (3,200 lumens), multiply by 1.34.

** Photometric data is based on a fixture
with two 32 W Compact Fluorescent PL-T
lamps (2,400 lumens each). For candlepower
values of fixtures with two 26 W PL-T lamps
(1,800 lumens each), multiply by 0.75. For
Candlepower values of fixtures with two 42 W

Total Luminaire Efficiency = 76.6%
CIE Type - Direct
Plane

Spacing
Criteria

0-180

1.48

90-270

1.62

Diagonal

1.54

REPORT NUMBER: CJBF32AN
32 W Fluorescent Lamp with Globe and 30° Angle Dome Reflector *
Coefficients of Utilization - Zonal Cavity Method
Effective Floor Cavity Reflectance 0.20
% Ceiling Rcc
% Walls

Lumens
42.08
124.46
205.20
273.31
299.53
283.93
240.60
181.91
110.47
50.28
18.05

110-120

5.01

120-130
130-140
140-150
150-160
160-170
170-180

1.80
1.13
0.05
0.00
0.00
0.00

0
1
2
3
4
5
6
7
8
9
10

Maximum Candela = 467
Located at Horizontal Angle = 90, Vertical Angle = 40
#1 - Vertical Plane through Horizontal Angles (90-270)
(Through Max. Cd.)
#2 - Horizontal Cone through Vertical Angle (40)
(Through Max. Cd.)

CIE Type - Semi-Direct
Plane

Spacing
Criteria
2.88

Diagonal

2.82

Zone
0-30
0-40
0-60
0-90

Lumens
17.70
61.05
132.44
236.78
336.66
421.68
485.34
517.29
513.72
468.70
352.77

110-120

200.85

120-130

73.54

130-140
140-150
150-160
160-170
170-180

11.28
1.12
0.31
0.06
0.00

30

10

0

30

10

70

50

30

10

50

30

10

50

30

10

50

30

10

0

90
81
73
66
60
55
50
47
43
40
38

90
76
65
57
50
44
39
36
32
30
27

90
72
59
50
42
37
32
28
25
23
21

90
69
54
44
37
31
27
23
21
18
17

88
78
70
63
58
53
49
45
42
39
36

88
74
64
55
48
43
39
35
32
29
27

88
71
58
49
42
36
32
28
25
23
21

88
67
53
44
36
31
27
23
21
18
17

83
70
60
52
46
41
37
33
30
28
26

83
67
56
47
40
35
31
27
24
22
20

83
64
52
42
35
30
26
23
20
18
16

79
67
57
50
44
39
35
32
29
27
25

79
64
53
45
39
34
30
26
24
22
20

79
62
50
41
35
30
26
22
20
18
16

75
63
54
47
42
37
34
31
28
26
24

75
61
51
43
37
33
29
26
23
21
19

75
59
48
40
34
29
25
22
20
18
16

73
58
46
38
32
27
23
20
18
16
14

Lumens
371.75
645.06
1228.52
1761.50

% Lamp
15.5
26.9
51.2
73.4

% Fixture
20.2
35.1
66.8
95.8

Zone
90-120
90-130
90-150
90-180
0-180

Lumens
73.34
75.13
76.32
76.32
1837.81

% Lamp
3.1
3.1
3.2
3.2
76.6

% Fixture
4.0
4.1
4.1
4.2
100.0

REPORT NUMBER: CMBF64G
64 W (two 32 W lamps) Fluorescent Fixture with Globe only **
Coefficients of Utilization - Zonal Cavity Method
Effective Floor Cavity Reflectance 0.20
% Ceiling Rcc
% Walls

Zone
0-10
10-20
20-30
30-40
40-50
50-60
60-70
70-80
80-90
90-100
100-110

50

50

80

70

50

30

10

0

Rw

70

50

30

10

70

50

30

10

50

30

10

50

30

10

50

30

10

0

0
1
2
3
4
5
6
7
8
9
10

90
76
67
60
54
49
45
41
38
35
33

90
70
58
49
43
37
33
29
26
24
22

90
65
51
41
34
29
25
22
19
17
15

90
60
45
35
28
23
19
16
14
12
11

85
71
63
56
50
46
42
38
36
33
31

85
66
55
46
40
35
31
28
25
23
21

85
61
48
39
32
27
23
20
18
16
14

85
57
42
33
26
22
18
15
13
11
10

76
58
48
40
35
31
27
24
22
20
18

76
54
43
34
28
24
21
18
16
14
13

76
51
38
29
23
19
16
14
12
10
9

68
51
42
35
30
26
23
21
19
17
16

68
48
37
30
25
21
18
16
14
12
11

68
45
34
26
21
17
14
12
10
9
8

60
45
36
30
26
23
20
18
16
15
14

60
42
32
26
21
18
16
14
12
11
10

60
40
29
23
18
15
12
10
9
8
7

57
36
26
20
15
12
10
8
7
9
5

Zonal Lumen Summary

Maximum Candela = 493
Located at Horizontal Angle = 0, Vertical Angle = 70
#1 – Vertical Plane through Horizontal Angles (0-180)
(Through Max. Cd.)
#2 – Horizontal Cone through Vertical Angle (70)
(Through Max. Cd.)

Zone
0-30
0-40
0-60
0-90

Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

Lumens
211.19
447.97
1206.31
2722.64

% Lamp
4.4
9.3
25.1
56.7

% Fixture
5.5
11.7
31.5
71.1

Zone
90-120
90-130
90-150
90-180
0-180

Lumens
1022.32
1095.85
1108.26
1108.63
3831.28

% Lamp
21.3
22.8
23.1
23.1
79.8

% Fixture
26.7
28.6
28.6
28.9
100.0

1249

Lighting

2.88

90-270

70

70

Zonal Lumen Summary

Total Luminaire Efficiency = 79.8%

0-180

Rw

80

Lighting: Explosionproof — Area — Fluorescent

Zone
0-10
10-20
20-30
30-40
40-50
50-60
60-70
70-80
80-90
90-100
100-110

PL-T Lamps. (3,200 lumens each) multiply by
1.34.

Code•Master™ PLT Factory Sealed Luminaire Photometric Data
Explosionproof, Dust-Ignitionproof

Integrally Ballasted. 26 W, 32 W, 42 W, 52 W, 64 W, 84 W Compact Fluorescent. For use with Threaded Metal Conduit.
** Photometric data is based on a fixture
with two 32 W Compact Fluorescent PL-T
lamps (2,400 lumens each). For candlepower
values of fixtures with two 26 W PL-T lamps
(1,800 lumens each), multiply by 0.75. For
Candlepower values of fixtures with two 42 W

PL-T lamps. (3,200 lumens each) multiply by
1.34.

Total Luminaire Efficiency = 66.5%
CIE Type - Direct
Plane

Spacing
Criteria

0-180

1.62

90-270

1.62

Diagonal

1.74

REPORT NUMBER: CMBF64ST
64 W (two 32 W lamps) Fluorescent Fixture with Globe and
Standard Dome Reflector **
Coefficients of Utilization - Zonal Cavity Method
Effective Floor Cavity Reflectance 0.20
% Ceiling Rcc

Lighting: Explosionproof — Area — Fluorescent

% Walls
Zone
0-10
10-20
20-30
30-40
40-50
50-60
60-70
70-80
80-90
90-100
100-110

Lumens
73.25
220.57
368.60
505.61
603.19
638.42
497.24
226.17
57.98
1.64
0.00

110-120

0.00

120-130
130-140
140-150
150-160
160-170
170-180

0.00
0.00
0.00
0.00
0.00
0.00

Maximum Candela = 808
Located at Horizontal Angle = 0, Vertical Angle = 35
#1 – Vertical Plane through Horizontal Angles (0-180)
(Through Max. Cd.)
#2 – Horizontal Cone through Vertical Angle (35)
(Through Max. Cd.)

CIE Type - Direct

Lighting

Spacing
Criteria

0-180

1.52

90-270

1.70

Diagonal

1.62

Zone
0-30
0-40
0-60
0-90

110-120

0.00
0.00
0.00
0.00
0.00
0.00
0.00

1250

30

10

0

50

30

10

70

50

30

10

50

30

10

50

30

10

50

30

10

0

0
1
2
3
4
5
6
7
8
9
10

79
72
65
59
53
49
45
41
38
35
33

79
69
59
51
45
39
35
32
29
26
24

79
66
54
45
38
33
29
25
23
20
18

79
63
50
41
34
28
24
21
19
16
15

77
70
63
57
52
47
43
40
37
34
32

77
67
58
50
44
39
34
31
28
26
24

77
64
53
45
38
33
29
25
22
20
18

77
62
49
40
33
28
24
21
18
16
15

74
64
55
48
42
37
33
30
27
25
23

74
62
52
43
37
32
28
25
22
20
18

74
60
48
40
33
28
24
21
18
16
15

71
62
53
46
40
36
32
29
26
24
22

71
60
50
42
36
31
27
24
22
19
18

71
58
47
39
32
28
24
21
18
16
15

68
59
51
44
39
35
31
28
26
23
22

68
58
48
41
35
31
27
24
21
19
17

68
56
46
38
32
27
23
20
18
16
14

66
55
45
37
30
26
22
19
17
15
13

Lumens
662.42
1168.03
2409.64
3191.04

% Lamp
13.8
24.3
50.2
66.5

% Fixture
20.7
36.6
75.5
99.9

Zone
Lumens
90-120
1.64
90-130
1.64
90-150
1.64
90-180
1.64
0-180 3192.68

% Lamp
0.0
0.0
0.0
0.0
66.5

% Fixture
0.1
0.1
0.1
0.1
100.0

Coefficients of Utilization - Zonal Cavity Method
Effective Floor Cavity Reflectance 0.20
% Ceiling Rcc

Lumens
62.13
187.93
317.49
428.14
471.22
454.23
384.77
276.31
157.68
13.45
0.00

120-130
130-140
140-150
150-160
160-170
170-180

50

70

REPORT NUMBER: CMBF64AN
64 W (two 32 W lamps) Fluorescent Fixture with Globe and
30° Angle Dome Reflector **

% Walls
Zone
0-10
10-20
20-30
30-40
40-50
50-60
60-70
70-80
80-90
90-100
100-110

70

Rw

Zonal Lumen Summary

Total Luminaire Efficiency = 57.4%

Plane

80

80

70

50

30

10

0

Rw

70

50

30

10

70

50

30

10

50

30

10

50

30

10

50

30

10

0

0
1
2
3
4
5
6
7
8
9
10

68
61
55
50
45
41
38
35
32
30
28

68
58
49
43
37
33
30
27
24
22
20

68
55
45
37
32
28
24
21
19
17
16

68
52
41
33
28
23
20
18
16
14
12

67
59
53
48
44
40
37
34
32
29
28

67
56
48
42
37
32
29
26
24
22
20

67
54
44
37
31
27
24
21
19
17
15

67
51
40
33
27
23
20
18
15
14
12

64
54
46
40
35
31
28
25
23
21
19

64
51
43
36
31
27
23
21
19
17
15

64
49
39
32
27
23
20
17
15
14
12

61
51
44
38
34
30
27
24
22
20
19

61
49
41
35
30
26
23
20
18
16
15

61
48
39
32
27
23
20
17
15
14
12

58
49
42
37
32
29
26
24
22
20
18

58
48
40
34
29
25
22
20
18
16
15

58
46
38
31
26
22
19
17
15
13
12

57
45
36
30
25
21
18
16
14
12
11

Zonal Lumen Summary
Maximum Candela = 731
Located at Horizontal Angle = 90, Vertical Angle = 37.5
#1 – Vertical Plane through Horizontal Angles (90-270)
(Through Max. Cd.)
#2 – Horizontal Cone through Vertical Angle (37.5)
(Through Max. Cd.)

Zone
0-30
0-40
0-60
0-90

Lumens
567.55
995.69
1921.14
2739.90

% Lamp
11.8
20.7
40.0
57.1

% Fixture
20.6
36.2
69.8
99.5

Zone
90-120
90-130
90-150
90-180
0-180

Lumens
13.45
13.45
13.45
13.45
2753.35

% Lamp
0.3
0.3
0.3
0.3
57.4

% Fixture
0.5
0.5
0.5
0.5
100.0

Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

Code•Master™ PLT Factory Sealed Luminaire Photometric Data
Explosionproof, Dust-Ignitionproof

Integrally Ballasted. 26 W, 32 W, 42 W, 52 W, 64 W, 84 W Compact Fluorescent. For use with Threaded Metal Conduit.
** Photometric data is based on a fixture
with two 32 W Compact Fluorescent PL-T
lamps (2,400 lumens each). For candlepower
values of fixtures with two 26 W PL-T lamps
(1,800 lumens each), multiply by 0.75. For
Candlepower values of fixtures with two 42 W

PL-T Lamps. (3,200 lumens each) multiply by
1.34.

Total Luminaire Efficiency = 67.2%
CIE Type - Direct
Plane

Spacing
Criteria

0-180

1.44

90-270

1.44

Diagonal

1.60

REPORT NUMBER: CMBF64DD
64 W (two 32 W lamps) Fluorescent Fixture with Globe and
Deep Dome Reflector **
Coefficients of Utilization - Zonal Cavity Method
Effective Floor Cavity Reflectance 0.20
% Ceiling Rcc
% Walls

90-100
100-110

Lumens
88.95
260.61
413.34
539.82
630.36
641.74
436.60
164.84
47.37
1.92
0.00

110-120

0.00

120-130
130-140
140-150
150-160
160-170
170-180

0.00
0.00
0.00
0.00
0.00
0.00

Maximum Candela = 933
Located at Horizontal Angle = 0, Vertical Angle = 7.5
#1 – Vertical Plane through Horizontal Angles (0-180)
(Through Max. Cd.)
#2 – Horizontal Cone through Vertical Angle (7.5)
(Through Max. Cd.)

CIE Type - Direct
Plane

Spacing
Criteria
0.82

Diagonal

0.92

Zone
0-30
0-40
0-60
0-90

Lumens
239.15
599.67
645.20
625.54
452.95
185.71
58.40
15.26
4.25
0.69
0.00

110-120

0.00

120-130
130-140
140-150
150-160
160-170
170-180

0.00
0.00
0.00
0.00
0.00
0.00

10

0

30

10

70

50

30

10

50

30

10

50

30

10

50

30

10

0

0
1
2
3
4
5
6
7
8
9
10

80
73
66
60
55
50
46
43
40
37
34

80
70
61
53
47
41
37
33
30
28
25

80
67
56
47
41
35
31
27
24
22
20

80
65
52
43
36
31
26
23
20
18
16

78
71
65
59
53
49
45
41
38
36
34

78
68
59
52
46
41
36
33
30
27
25

78
66
55
47
40
35
30
27
24
22
20

78
63
52
43
36
30
26
23
20
18
16

75
66
57
50
44
39
35
32
29
26
24

75
63
53
45
39
34
30
27
24
21
19

75
61
50
42
35
30
26
23
20
18
16

71
63
55
48
42
38
34
31
28
26
24

71
61
52
44
38
33
29
26
23
21
19

71
60
49
41
35
30
26
23
20
18
16

69
60
53
46
41
37
33
30
27
25
23

69
59
50
43
37
33
29
26
23
21
19

69
58
48
40
34
29
25
22
20
18
16

67
56
47
39
33
28
24
21
19
16
15

Lumens
762.91
1302.73
2574.82
3223.63

% Lamp
15.9
27.1
53.6
67.2

% Fixture
23.7
40.4
79.8
99.9

Zone
90-120
90-130
90-150
90-180
0-180

Lumens
1.92
1.92
1.92
1.92
3225.55

% Lamp
0.0
0.0
0.0
0.0
57.4

% Fixture
0.1
0.1
0.1
0.1
100.0

REPORT NUMBER: CMBF64HB
64 W (two 32 W lamps) Fluorescent Fixture with Globe and High Bay Reflector **
Coefficients of Utilization - Zonal Cavity Method
Effective Floor Cavity Reflectance 0.20
% Ceiling Rcc
% Walls

Zone
0-10
10-20
20-30
30-40
40-50
50-60
60-70
70-80
80-90
90-100
100-110

30

50

80

70

50

30

10

0

Rw

70

50

30

10

70

50

30

10

50

30

10

50

30

10

50

30

10

0

0
1
2
3
4
5
6
7
8
9
10

70
66
62
58
55
51
48
46
43
41
38

70
64
59
54
50
46
42
39
37
34
32

70
63
56
51
46
42
38
35
33
30
28

70
61
54
48
43
39
35
32
30
28
26

68
65
61
57
54
50
47
45
42
40
38

68
63
58
53
49
45
42
39
36
34
32

68
62
55
50
45
41
38
35
32
30
28

68
60
53
47
43
39
35
32
30
28
26

65
61
56
51
48
44
41
38
36
33
31

65
59
54
49
44
41
37
35
32
30
28

65
58
52
47
42
38
35
32
30
27
26

63
58
54
50
46
43
40
37
35
33
31

63
57
52
48
44
40
37
34
32
30
28

63
57
51
46
42
38
35
32
29
27
25

60
56
52
49
45
42
39
37
34
32
30

60
56
51
47
43
39
36
34
31
29
27

60
55
50
45
41
37
34
32
29
27
25

59
54
49
44
40
36
33
31
28
26
25

Zonal Lumen Summary
Maximum Candela = 2540
Located at Horzonatl Angle = 0, Vertical Angle = 5
#1 – Vertical Plane through Horizontal Angles (0-180)
(Through Max. Cd.)
#2 – Horizontal Cone through Vertical Angle (5)
(Through Max. Cd.)

Zone
0-30
0-40
0-60
0-90

Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

Lumens
1484.03
2109.57
2748.23
2826.12

% Lamp
30.9
43.9
57.3
58.9

% Fixture
52.5
74.6
97.2
100.0

Zone
Lumens
90-120
0.69
90-130
0.69
90-150
0.69
90-180
0.69
0-180 2628.80

% Lamp
0.0
0.0
0.0
0.0
58.9

% Fixture
0.0
0.0
0.0
0.0
100.0

1251

Lighting

0.82

90-270

50

70

Zonal Lumen Summary

Total Luminaire Efficiency = 58.9%

0-180

70

Rw

Lighting: Explosionproof — Area — Fluorescent

Zone
0-10
10-20
20-30
30-40
40-50
50-60
60-70
70-80
80-90

80

APL Two and Four Lamp Fluorescent Factory Sealed Luminaires
Explosionproof, Dust-Ignitionproof

120-277 V, 120 V V, 277 V V, 347 V V, 50/60 Hz. For use with Threaded Metal Conduit. Suitable for Wet Locations and Paint Spray Booths.
Class I, Division 1 and 2, Groups C,D
Class II, Division 1 and 2, Groups E,F,G
Class III
Marine Type Electric Fixture Inside Drip-Proof
Type

Applications
•	 Classified areas where ignitable gases and vapors, dusts,
paint residue, paint powder, or corrosive atmospheres may be
present, or where excessive moisture is a problem.
•	 Approved for mounting directly inside a paint spray booth.
Complies with NEC 516-3(b) and NFPA No. 33.
•	 Typical applications include refineries, chemical and
petrochemical plants, textile mills, grain elevators and other
grain-processing facilities, pharmaceutical plants, and paint
spray areas.

Two Lamp APL

Lighting

Lighting: Explosionproof — Area — Fluorescent

Features
•	 Factory sealed fixture. No external seals needed for 	
classified areas.
•	 Two lamp:
— Compact size
— Uses two single-ended biaxial 40 W fluorescent lamps in a
fixture only 29”/736.6 mm long
— Available for 120-277 V, 50/60 Hz
— Available for 120 V, 277 V, 347 V, 50/60 Hz V
•	 Four lamp:
— Uses four single-ended biaxial 40 W fluorescent lamps
mounted tandem in a 52-1/2”/1333.5 mm long fixture
— Available for 120-277 V, 50/60 Hz
— Available for 120 V, 277 V, 347 V, 50/60 Hz V
•	 Easy to install. Has three 3/4”/19.1 mm conduit hubs on each
end of fixture. Two close-up plugs per end are furnished.
Mounts straight down, or at 45° angle to either side. Can be
mounted horizontally, or mounted vertically on wall. Gasketed
end caps remove easily for wiring or relamping.
•	 Explosionproof, heat-resistant and impact-resistant glass 	
tubes protect lamps.
•	 Cool-operating fluorescent lamps provide excellent color
rendition and high lumen output per watt. Average lamp life 	
is 20,000 hours. Lamps are furnished.
•	 Corrosion resistant.
•	 Reflector (optional) is designed for efficient distribution. 	
Installs and removes using only a screwdriver.
•	 Appleton APL fixtures are supplied with energy-saving Class
P ballasts, equipped with an automatic thermally activated
protective device.

Two Lamp APL with Optional Reflector

Four Lamp APL

Standard Materials
•	 End housing: copperfree (4/10 of 1% max.) aluminum
•	 Housing hood and optional reflectors: heavy gauge aluminum
•	 Wire guard: stainless steel

Four Lamp APL with Optional Reflector

Standard Finishes
•	 End housings and hood: two-coat baked gray epoxy finish
•	 Reflector: white baked powder coat polyester reflecting surface

Certifications and Compliances
•	
•	
•	
•	

UL Standard: UL 1598, UL 844
UL Listed: E10794
CSA Standard: C22.2 No. 250, C22.2 No. 137
CSA Certified: 025428

Illustrated Feature

APL Fixture shown with explosionproof,
gasketed end caps removed, allowing
access for wiring and relamping.

V CSA Certification only.

1252

Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

APL Two and Four Lamp Fluorescent Factory Sealed Luminaires
Explosionproof, Dust-Ignitionproof

120-277 V, 120 V V, 277 V V, 347 V V, 50/60 Hz. For use with Threaded Metal Conduit. Suitable for Wet Locations and Paint Spray Booths.
Class I, Division 1 and 2, Groups C,D
Class II, Division 1 and 2, Groups E,F,G
Class III
Marine Type Electric Fixture Inside Drip-Proof
Type

Lamps
(Included)

Volts

Hub Size
(Inches)

Temperature
Rating

Supply Wire
°F/°C

Catalog
Number

(2) 40 W F40BX

120-277

3/4

T-6

140/60

APL240BU

(2) 40 W F40BX

3477

3/4

T-6

140/60

APL240-347 V

(4) 40 W F40BX

120-277

3/4

T6

140/60

APL440BU

(4) 40W F40BX

347

3/4

T-6

60°C

Luminaires Without Reflector
Two Lamp

Four Lamp

Aluminum reflector with white powder coat polyester finish
Two Lamp

APL2R

Four Lamp

APL4R

Two Lamp

APL-2-GU-SS

Four Lamp

ARS-GU-SS

Wire Guard

Lighting: Explosionproof — Area — Fluorescent

APL440-347 V

Exit Sign — 6” red lettering on white enamel field
Two Lamp Only

APLEXR
Lighting

V CSA Certification only.
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

1253

APL Two Lamp Factory Sealed Luminaire Dimensions and Photometric Data
Explosionproof, Dust-Ignitionproof

120-277 V, 120 V V, 277 V V, 347 V V, 50/60 Hz. For use with Threaded Metal Conduit. Suitable for Wet Locations and Paint Spray Booths.

Dimensions
(3) 3/4" Conduit Holes on
Each End, Furnished with
Two Close-Up Plugs

5.5"/
139.7 mm

22.75"/
577.9 mm
29.00"/
736.6 mm
7.75"/
196.9 mm

8.75"/
222.3 mm

8.75"/
222.3 mm
16.00"/
406.4 mm
End View —With Optional Reflector

Side View — Without Optional Reflector

Lighting

Lighting: Explosionproof — Area — Fluorescent

APL240

Photometric Data

Total Luminaire Efficiency = 81.4%
CIE Type - Direct
Plane

Spacing
Criteria

0-180

1.28

90-270

1.50

Diagonal

1.54

Zone

Lumens

REPORT NUMBER: APL240R
Lamps: Two 40 W Two-Foot Explosionproof Fluorescent
Coefficients of Utilization - Zonal Cavity Method
Effective Floor Cavity Reflectance 0.20
% Ceiling Rcc
% Walls Rw

80
70

50

70
30

10

70

50

50
30

10

50

30

30
10

50

30

10
10

50

30

0
10

0

0 97 97 97 97 95 95 95 95 90 90 90 87 87 87 83 83 83 81

0-10

143.58

1 88 84 81 77 86 82 79 76 79 76 74 76 73 71 73 71 69 68

10-20

422.85

2 80 73 67 62 78 71 66 62 68 64 60 66 62 59 63 60 57 56

20-30

667.66

3 72 64 57 51 70 62 56 51 60 54 50 58 53 49 55 51 48 46

30-40

852.03

4 66 56 49 43 64 55 48 43 53 47 42 51 46 41 49 45 41 39

40-50

948.58

5 61 50 42 37 59 49 42 36 47 41 36 45 40 35 44 39 35 33

50-60

920.43

6 56 44 37 32 54 44 37 31 42 36 31 41 35 31 40 34 31 29

60-70

709.76

7 52 40 33 28 50 39 33 28 38 32 27 37 31 27 36 31 27 25

70-80

373.12

8 48 37 29 24 47 36 29 24 35 29 24 34 28 24 33 28 24 22

80-90

87.31

9 45 33 27 22 43 33 26 22 32 26 22 31 26 22 30 25 21 20

90-100

0.00

10 42 31 24 20 41 30 24 20 29 24 20 29 23 19 28 23 19 18

100-110

0.00

110-120

0.00

Zonal Lumen Summary

120-130

0.00

Zone

Lumens

% Lamp

% Fixture

Zone

Lumens

% Lamp

130-140

0.00

0-30

1234.09

19.6

24.1

90-120

0.00

0.0

140-150

0.00

0-40

2086.12

33.1

40.7

90-130

0.00

0.0

0.0

150-160

0.00

0-60

3955.13

62.8

77.2

90-150

0.00

0.0

0.0

160-170

0.00

0-90

5125.31

81.4

100.0

90-180

0.00

0.0

0.0

170-180

0.00

5125.32

81.4

100.0

0-180

% Fixture
0.0

V CSA Certification only.

1254

Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

APL Four Lamp Fluorescent Factory Sealed Luminaire Photometric Data
Explosionproof, Dust-Ignitionproof

120-277 V, 120 V V, 277 V V, 347 V V, 50/60 Hz. For use with Threaded Metal Conduit. Suitable for Wet Locations and Paint Spray Booths.

Total Luminaire Efficiency = 79.9%

REPORT NUMBER: APL440R
Lamps: Four 40 W Explosionproof Fluorescent

CIE Type - Direct
Plane

Spacing
Criteria

0-180

1.30

Coefficients of Utilization - Zonal Cavity Method

90-270

1.50

Effective Floor Cavity Reflectance 0.20

Diagonal

1.54

% Ceiling Rcc
% Walls Rw

Zone

50

70
30

10

70

50

50
30

10

50

30

30
10

50

30

10
10

50

30

0
10

0

Lumens

0 95 95 95 95 93 93 93 93 89 89 89 85 85 85 82 82 82 80

277.70

1 87 83 79 76 85 81 78 75 78 75 73 74 72 70 72 70 68 67

10-20

817.61

2 78 72 66 61 76 70 65 61 67 63 59 65 61 58 62 59 56 55

20-30

1291.05

3 71 62 56 50 69 61 55 50 59 53 49 57 52 48 54 51 47 45

30-40

1648.83

4 65 55 48 42 63 54 47 42 52 46 41 50 45 41 48 44 40 38

40-50

1837.13

5 59 49 41 36 58 48 41 36 46 40 35 45 39 35 43 38 35 33

50-60

1787.64

6 55 44 36 31 53 43 36 31 41 35 31 40 35 30 39 34 30 28

60-70

1379.79

7 51 39 32 27 49 39 32 27 38 31 27 36 31 27 35 30 26 25

70-80

722.47

8 47 36 29 24 46 35 29 24 34 28 24 33 28 24 32 27 24 22

80-90

148.89

9 44 33 26 22 43 32 26 21 31 25 21 31 25 21 30 25 21 20
10 41 30 24 19 40 30 24 19 29 23 19 28 23 19 28 23 19 18

90-100

0.00

100-110

0.00

110-120

0.00

Zonal Lumen Summary

0.00

Zone

Lumens

% Lamp

% Fixture

Zone

Lumens

% Lamp

0.00

0-30

2386.36

19.2

24.1

90-120

0.00

0.0

0.0

140-150

0.00

0-40

4035.19

32.5

40.7

90-130

0.00

0.0

0.0

150-160

0.00

0-60

7659.96

61.8

77.3

90-150

0.00

0.0

0.0

160-170

0.00

0-90

9911.11

79.9

100.0

90-180

0.00

0.0

0.0

170-180

0.00

9911.11

79.9

100.0

0-180

(3) 3/4" Conduit Holes on
Each End, Furnished with
Two Close-Up Plugs
5.5"/139.7 mm

% Fixture

46.63"/
1184.4 mm
52.5"/
1333.5 mm

7.75"/
196.9 mm

8.75"/
222.3 mm

8.75"/
222.3 mm
16.00"/
406.4 mm

Side View — Without Optional Reflector

End View —With Optional Reflector

V CSA Certification only.
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

1255

Lighting

120-130
130-140

Lighting: Explosionproof — Area — Fluorescent

0-10

80
70

EFU Fluorescent Factory Sealed Luminaires
Explosionproof, Dust-Ignitionproof

UNILETS® for use with Threaded Metal Conduit Suitable for use in Wet Locations
Class I, Division 1 and 2, Groups C, D
Class II, Division 1 and 2, Groups E, F, G
Class III

Applications
•	 Classified areas such as inside paint spray booths, in
pharmaceutical firms, paint-manufacturing plants, printing
plants or any location where ignitable dust, fumes, gases,
paint residue, paint powder or corrosive atmospheres may be
present.

Lighting: Explosionproof — Area — Fluorescent

Features
•	 Factory sealed unit – no external seals required. 	
Installation is easy.
•	 A wide range of ballasts and voltages are available for both
domestic and export applications.
•	 Three hubs on each end of fixture provide for straight-down
mounting or at 45° to either side. Two close-up plugs furnished
for each end of fixture.
•	 Explosionproof, impact-resistant and heat-resistant glass tubes
protect lamps.
•	 Reflectors can easily be removed for replacement or cleaning
using only a screwdriver.
•	 Appleton EFU fixtures are supplied with Class P ballasts,
equipped with an automatic thermally activated protective
device. They offer protection against excessive voltage, internal
ballast short circuiting, inadequate lamp maintenance and
improper fixture application.
•	 Non-sparking exterior surfaces for safer operation.

Standard Materials
•	 Hood, housings and reflectors: copperfree (4/10 of 1% max.)
aluminum
•	 Hood and housings: gray epoxy finish
•	 Reflectors: white baked enamel inside and gray epoxy outside

Options
•	 Emergency battery pack. Suffix -EL.
•	 Fusing: ARS, AH and AVH fixtures supplied as standard with
Class P ballasts with built-in protective device. Additional
external fusing available at extra cost. Suffix -F.

Lighting

Certifications and Compliances
•	
•	
•	
•	

UL Standard: UL 1598, UL 844
UL Listed: E10794
CSA Standard: C22.2 No. 250, C22.2 No. 137
CSA Certified: 025428

Explosionproof caps easily removed
(shown with caps removed) for easy access.
Allows quick wiring or relamping.

1256

Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

EFU Fluorescent Factory Sealed Luminaires
Explosionproof, Dust-Ignitionproof

UNILETS® for use with Threaded Metal Conduit Suitable for use in Wet Locations
Class I, Division 1 and 2, Groups C, D
Class II, Division 1 and 2, Groups E, F, G
Class III

Lamp

Volts

Two Lamps

Rapid Start VHO-SHO
T-12 Recessed Double Contact
48” 1500MA

Catalog
Number ➋

120-277 V, 50/60 Hz

3/4

T-6

140/60 ARS232-BU ➊

347 V, 60 Hz

3/4

T-6

140/60 ARS232-347 V➊

120-277 V, 50/60 Hz

3/4

T-6

140/60 ARS240-BU ➊

347 V, 60 Hz

3/4

T-6

140/60 ARS240-347 V➊

120-277 V, 50/60 Hz

3/4

T-6

140/60 AH260-BU

347 V, 60 Hz

3/4

T-6

140/60 AH260-347 V

120 V, 60 Hz
277 V, 60 Hz
347 V, 60 Hz

3/4
3/4
3/4

T-6
T-6
T-6

140/60 AVH210-118
140/60 AVH210-277
140/60 AVH210-347 V

120-277 V, 50/60 Hz

3/4

T-6

140/60 ARS332-BU ➊

347 V, 60 Hz

3/4

T-6

140/60 ARS332-347 V➊

120-277 V, 50/60 Hz

3/4

T-6

140/60 ARS340-BU

347 V, 60 Hz

3/4

T-6

140/60 ARS340-347 V

120-277 V, 50/60 Hz

3/4

T-6

140/60 AH360-BU

347 V, 60 Hz

3/4

T-6

140/60 AH360-347 V

120-277 V, 50/60 Hz

3/4

T-6

140/60 ARS432-BU ➊

347 V, 60 Hz

3/4

T-6

140/60 ARS432-347 V➊

120-277 V, 50/60 Hz

3/4

T-6

140/60 ARS440-BU

347 V, 60 Hz

3/4

T-6

140/60 ARS440-347 V

120-277 V, 50/60 Hz

3/4

T-6

140/60 AH460-BU

347 V, 60 Hz

3/4

T-6

140/60 AH460-347 V

120 V, 60 Hz
277 V, 60 Hz
347 V, 60 Hz

3/4
3/4
3/4

T-6
T-6
T-6

140/60 AVH410-118
140/60 AVH410-277
140/60 AVH410-347 V

Three Lamps
32 W
Rapid Start 	
T8 Bi-Pin
48” 265MA
40 W
Rapid Start 	
T12 Bi-Pin
48” 430MA
60 W
Rapid Start High Output
T-12 Recessed Double Contact
48” 800MA

Lighting: Explosionproof — Area — Fluorescent

32 W
Rapid Start 	
T8 Bi-Pin
48” 265MA
40 W
Rapid Start 	
T12 Bi-Pin
48” 430MA
60 W
Rapid Start High Output
T-12 Recessed Double Contact
48” 800MA
110 W

Hub Size Temperature Supply Wire
(Inches)
Rating
°F/°C

Four Lamps

Rapid Start Very High Output
T-12 Recessed Double Contact
48” 1500MA

Protector for two-lamp fluorescent fixture
Fits two lamp 48” fixtures only (ARS, AH and AVH series)
UV stabilized polycarbonate.

EFP248

NOTE: In paint spray areas, solvents and thinners may “cloud” the polycarbonate. Light transmission characteristics may be reduced.
➊ For Emergency Battery Pack, add suffix -EL.
➋ Fluorescent lamps are not included. Supplied with automatic resetting dual protected “Class P” ballast. For additional external fusing, add suffix -F.
V CSA Certification only.
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

1257

Lighting

32 W
Rapid Start 	
T8 Bi-Pin
48” 265MA
40 W
Rapid Start 	
T12 Bi-Pin
48” 430MA
60 W
Rapid Start High Output
T-12 Recessed Double Contact
48” 800MA
110 W

EFU Fluorescent Factory Sealed Luminaire Ballast Data and Dimensions
Explosionproof, Dust-Ignitionproof

UNILETS® for use with Threaded Metal Conduit Suitable for use in Wet Locations

Catalog
Number

Lamps

Hz

Voltage

Operating
Amps

Input
Watts

Starting Temperature
°F/°C

Lighting: Explosionproof — Area — Fluorescent

32 W Rapid Start T-8 Bi-Pin 48” 265 mA
ARS232-BU

2

50/60

120-277

.52-.22

62-60

0/-18

ARS232-347 V

2

60

347

.20

59

0/-18

ARS332-BU

3

50/60

120-277

.78-.33

93-93

0/-18

ARS332-347 V

3

60

347

.30

86

0/-18

ARS432-BU

4

50/60

120-277

1.03-.43

124-120

0/-18

ARS432-347 V

4

60

347

.40

118

0/-18

50/60

120-277

.70-.35

84-42

50/10

40 W Rapid Start T-12 Bi-Pin 48” 430 mA
ARS240-BU

2

ARS240-347 V

2

60

347

.30

96

50/10

ARS340-BU

3

50/60

120-277

.99-.45

114

50/10

ARS340-347 V

3

60

347

.50

140

50/10

ARS440-BU

4

50/60

120-277

1.40-.70

168-84

50/10

ARS440-347 V

4

60

347

.60

192

50/10

120-277

1.05-.55

122-86

-20/-29

60 W Rapid Start High Output T-12 Bi-Pin 48” 800 mA
AH260-BU

2

50/60

AH260-347 V

2

60

347

.50

145

-20/-29

AH360-BU

3

50/60

120-277

1.54-.66

182

-20/-29

AH360-347 V

3

60

347

.90

256

-20/-29

AH460-BU

4

50/60

120-277

2.10-1.10

244-172

-20/-29

AH460-347 V

4

60

347

1.00

290

-20/-29

AVH210-118

2

60

120

2.60

300

-20/-29

AVH210-277

2

60

277

.98

250

-20/-29

AVH210-347 V

2

60

347

.90

250

-20/-29

AVH410-118

4

60

120

5.20

600

-20/-29

AVH410-277

4

60

277

1.96

500

-20/-29

AVH410-347 V

4

60

347

1.80

500

-20/-29

Dimensions in In/mm

6.00"/
152.4 mm

6.00"/
152.4 mm

Lighting

110 W Rapid Start VHO-SHO T-12 Bi-Pin 48” 1500 mA

8.75"/
222.3 mm

4.00"/101.6 mm

No. of Lamps

1258

A

B

C

D

E

2

46-5/8/1184.4

52-7/16/1332.0

8-3/4/222.3

5-1/2/139.7

15/381.0

3

46-5/8/1184.4

52-7/16/1332.0

8-3/4/222.3

5-1/2/139.7

19-1/4/489.0

4

46-5/8/1184.4

52-7/16/1332.0

11-7/16/290.6

14/355.6

23-1/2/596.9

Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

EFU Fluorescent Factory Sealed Luminaire Photometric Data
Explosionproof, Dust-Ignitionproof

UNILETS® for use with Threaded Metal Conduit Suitable for use in Wet Locations
* Data is based on F32 TB Rapid Start
Lamps. For other lamps use the following
multipliers: 60 W Cool White – 1.50; and 110
W VHO – 2.19. Candlepower distribution
curves and other coefficients of utilization
tables are available on request.
Zone

Lumens

Total Luminaire Efficiency = 78.6%

0-10
10-20
20-30

139.50
402.70
620.06

CIE Type - Direct

30-40

767.75

0-180

1.28

40-50

821.07

90-270

1.36

50-60

776.93

Diagonal

1.44

60-70

597.35

70-80
80-90

299.18
57.43

Zone

0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
Lumens

Plane

Zonal Lumen Summary
Zone
0-30
0-40
0-60
0-90
90-120
90-130
90-150
90-180
0-180

Lumens % Lamp % Fixture
1162.26 20.4
25.9
1930.01 33.9
43.1
3528.01 61.9
78.7
4481.97 78.6
100.0
0.00
0.0
0.0
0.00
0.0
0.0
0.00
0.0
0.0
0.00
0.0
0.0
4481.97 78.6
100.0

Total Luminaire Effieciency = 96.8%
CIE Type - Direct

249.94
726.14
1122.12

30-40

1392.92

0-180

1.26

40-50

1496.9

90-270

1.38

50-60

1397.8

Diagonal

1.46

60-70

1087.36

70-80
80-90

557.01
103.54

Lumens

Spacing
Criteria

Plane

Zonal Lumen Summary
Zone
0-30
0-40
0-60
0-90
90-120
90-130
90-150
90-180
0-180

Lumens % Lamp % Fixture
2098.20 25.0
25.8
3491.12 41.6
42.9
6385.81 76.0
78.5
8133.73 96.8
100.0
0.00
0.0
0.0
0.00
0.0
0.0
0.00
0.0
0.0
0.00
0.0
0.0
8133.73 96.8
100.0

Total Luminaire Effieciency = 70.9%
CIE Type - Direct

237.58
692.75
1081.02

30-40

1352.75

0-180

1.28

40-50

1467.39

90-270

1.42

50-60

1408.53

Diagonal

1.48

60-70

1130.45

70-80
80-90

598.78
117.42
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00

Spacing
Criteria

Plane

1
2
3
4
5
6
7
8
9
10

Zone
0-30
0-40
0-60
0-90
90-120
90-130
90-150
90-180
0-180

Lumens % Lamp % Fixture
2011.34 17.6
24.9
3364.10 29.5
41.6
6240.02 54.7
77.2
8086.66 70.9
100.0
0.00
0.0
0.0
0.00
0.0
0.0
0.00
0.0
0.0
0.00
0.0
0.0
8086.66 70.9
100.0

Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

70

50

30

10

0

70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10

0

86
78
71
65
59
55
51
47
44
41

82
71
62
55
49
44
40
36
33
31

78
66
56
48
42
37
33
29
27
24

75
61
51
43
36
32
28
25
22
20

83
76
69
63
58
53
49
46
43
40

80
70
61
54
48
43
39
36
33
30

77
65
55
47
41
36
32
29
26
24

74
60
50
42
36
32
28
25
22
20

77
67
59
52
46
42
38
35
32
29

74
63
53
46
40
36
32
29
26
24

72
59
49
42
36
31
28
24
22
20

74
64
56
50
45
40
37
34
31
29

72
61
52
45
40
35
31
28
26
23

70
58
48
41
35
31
27
24
22
20

71
62
54
48
43
39
36
33
30
28

69
59
51
44
39
34
31
28
25
23

68
56
47
41
35
31
27
24
22
20

66
55
46
39
33
29
25
23
20
18

REPORT NUMBER: ARS332
Lamps: Three 32 W Explosionproof Fluorescent with Reflector *
Coefficients of Utilization - Zonal Cavity Method
Effective Floor Cavity Reflectance 0.20
% Ceiling Rcc

80

70

50

30

10

0

70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10

0

0 115 115 115 115 113 113 113 113 108 108 108 103 103 103 99 99 99 97
1
2
3
4
5
6
7
8
9
10

105 101
96 87
87 77
79 68
73 60
67 54
62 49
58 44
54 41
50 38

97
81
69
59
51
45
40
36
33
30

93
75
62
52
45
39
34
30
27
25

103
93
84
77
71
65
60
56
53
49

99
86
75
66
59
53
49
44
40
37

95
80
68
58
51
45
40
36
32
30

91
74
62
52
45
39
34
30
27
25

94
82
72
64
57
51
47
42
39
36

91
77
66
57
50
44
39
35
32
29

88
73
60
51
44
38
34
30
27
24

91
79
69
62
55
50
45
41
38
35

88
75
64
55
49
43
38
35
31
29

86
71
59
50
44
38
34
30
27
24

87
76
67
59
53
48
44
40
37
34

85
72
62
54
48
42
38
34
31
28

83
69
58
50
43
38
33
30
27
24

81
67
56
48
41
36
31
28
25
22

REPORT NUMBER: ARS432
Lamps: Four 32 W Explosionproof Fluorescent with Reflector *
Coefficients of Utilization - Zonal Cavity Method
Effective Floor Cavity Reflectance 0.20
% Ceiling Rcc
% Walls Rw

Zonal Lumen Summary

80

0 94 94 94 94 91 91 91 91 87 87 87 84 84 84 80 80 80 79

% Walls Rw

0-10
10-20
20-30

90-100
100-110
110-120
120-130
130-140
140-150
150-160
160-170
170-180

Effective Floor Cavity Reflectance 0.20
% Ceiling Rcc

80

70

50

30

10

0

70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10

0

0 84 84 84 84 82 82 82 82 79 79 79 75 75 75 72 72 72 71
1 77 74 70 68 75 72 69 67 69 67 64 66 64 62 64 62 61 59
2
3
4
5
6
7
8
9
10

70
63
58
53
49
45
42
39
37

64
56
49
44
39
35
32
29
27

59
50
43
37
33
29
26
23
21

55
45
38
32
28
24
22
19
18

68
62
56
51
47
44
41
38
36

62
54
48
43
38
35
32
29
27

58
49
42
37
32
29
26
23
21

54
44
37
32
28
24
22
19
17

60
52
46
41
37
34
31
28
26

56
48
41
36
32
28
25
23
21

53
44
37
32
27
24
21
19
17

57
50
45
40
36
33
30
27
25

54
46
40
35
31
28
25
23
21

51
43
36
31
27
24
21
19
17

55
48
43
38
35
32
29
27
25

53
45
39
34
30
27
24
22
20

50
42
36
31
27
24
21
19
17

49
41
34
29
25
22
20
18
16

1259

Lighting

Zone

0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00

Coefficients of Utilization - Zonal Cavity Method

% Walls Rw

0-10
10-20
20-30

90-100
100-110
110-120
120-130
130-140
140-150
150-160
160-170
170-180

REPORT NUMBER: ARS232
Lamps: Two 32 W Explosionproof Fluorescent with Reflector *

Lighting: Explosionproof — Area — Fluorescent

90-100
100-110
110-120
120-130
130-140
140-150
150-160
160-170
170-180

Spacing
Criteria

PAPL Portable Two and Four Lamp Fluorescent Factory Sealed Luminaire
Explosionproof, Dust-Ignitionproof

120 V. Suitable for Wet Locations and Paint Spray Booths. UL Listed for Horizontal use only.
Class I, Division 1 and 2, Groups C, D

Applications
•	 Classified areas where ignitable gases and vapors, dusts,
paint residue, paint powder, or corrosive atmospheres may be
present, or where excessive moisture is a problem.
•	 Approved for using directly inside a paint-spray booth.
Complies with NEC 516-3(c) and NFPA No. 33.
•	 Typical applications include aircraft manufacturing and
maintenance facilities, refineries, chemical and petrochemical
plants, textile mills, grain elevators and other grain-processing
facilities, pharmaceutical plants, paint-spray areas, and where
the permanent mounting of a fixture is not practical.
•	 UL approved for horizontal use only.

Lighting

Lighting: Explosionproof — Area — Fluorescent

Features
•	 Factory sealed fixture. No external seals needed for 	
classified areas.
•	 Compact size. Uses two or four single-ended biaxial 40 W
fluorescent lamps in a portable fixture. (2 lamp cart overall
length is 38-1/2”/978 mm, 4 lamp cart overall length is 62”).
•	 Gasketed end caps remove easily for wiring and relamping.
•	 Teflon-coated stainless steel wire guard supplied standard.
•	 Adjustable aluminum mounting frame allows fixtures to pivot at
45° increments in a 180° horizontal plane.
•	 50’ of 16-3 SOW cord with nonmetallic explosionproof plug
prewired for 120 V.
•	 Static discharge wheels.
•	 Explosionproof, heat-resistant and impact-resistant glass tubes
help protect the lamp.
•	 Cool-operating fluorescent lamps provide excellent color
rendition and high lumen output per watt. Average lamp life is
20,000 hours.
•	 Corrosion resistant.
•	 Reflectors (optional) are designed for efficient distribution.
Easily installed using only a screwdriver.
•	 Energy-saving Class P ballasts, with automatic thermally
activated protective device.
•	 Fixture uses Appleton’s ECP1523 Plug, which is UL Classified
for use with Killark® UGR and Crouse-Hinds® ENR series
receptacles, as well as Appleton’s U-Line receptacles.

4-Lamp Luminaire

2-Lamp Luminaire

Standard Materials
•	 End housing, cord grip and elbow: copperfree (4/10 of 1%
max.) aluminum
•	 Housing hood, frame and optional reflectors: heavy gauge
aluminum
•	 Wheels: static discharge rubber
•	 Guard: Teflon coated stainless steel
•	 Plug: aluminum

Standard Finishes
•	 End housings and hood: two-coat baked gray epoxy finish
•	 Reflector: white baked powder coat polyester
•	 Frame assembly: natural aluminum

Certifications and Compliances
•	
•	
•	
•	

UL Standard: UL 1598, UL 844
UL Listed: E59147
CSA Standard: C22.2 No. 12, C22.2 No. 137
cUL Listed: E59147

1260

Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

PAPL Portable Two and Four Lamp Fluorescent Factory Sealed Luminaire
Explosionproof, Dust-Ignitionproof

120 V. Suitable for Wet Locations and Paint Spray Booths. UL Listed for Horizontal use only.
Class I, Division 1 and 2, Groups C, D

Lamps
Included

Volts

Temperature
Rating

Catalog
Number

T6

PAPL240-120

Two-Lamp Luminaires Less Reflector
(2) 40 W F40BX

120

Reflector Only
Aluminum reflector with white powder coat polyester finish
APL2R

(4) 40 W F40BX
Two-Lamp Luminaire Illustrated

120

T6

PAPL440-120

Reflector Only
Aluminum reflector with white powder coat polyester finish

APL4R

Dimensions in Inches/Millimeters

18.00"/
457.2 mm

13.88"/
352.6 mm

Lighting: Explosionproof — Area — Fluorescent

Four-Lamp Luminaires Less Reflector

8.50"/
215.9 mm

5.00"/
127.0 mm
Dia.

Lighting

14.00"/
355.6 mm
18.00"/
457.2 mm

Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

62.00"/1574.8 mm 4 Lamp
38.50"/977.9 mm 2 Lamp

1261

FD Series Cylindrical Fluorescent Luminaires

Standard and Emergency Battery Back-Up – Flameproof
Zone 1 & 2 – 21 & 22
II 2 GD
ATEX / IECEx
IP66/68

Applications
•	 Can be installed in hazardous areas designated as Zone 1, 2, 21
and 22.
•	 For use in locations where a high degree of corrosion resistance
is required.
•	 For indoor/outdoor use where protection against dirt, water and
moisture is necessary.
•	 Typical applications include oil refineries, petrochemical
facilities, pulp and paper, mills, painting, sewage and water
treatment facilities, warehouses, underground tunnels and
general manufacturing facilities.

2 x 58 W

Lighting: Explosionproof — Area — Fluorescent

Features
•	 Impact resistant borosilicate glass sealed tube.
•	 Easy access to lamps through gray painted Zamak 	
threaded entry cap.
•	 Supplied with O-ring for improved ingress protection.
•	 Corrosion-resistant gray painted Zamak.
•	 Supplied with energy efficient and self induction ferromagnetic
ballast on a removable gear tray.
•	 Quick and easy installation of fluorescent lighting fixtures with
2G11 and G13 lamp holders.
•	 Supplied with external and internal ground/earth connection.
•	 Fixture supplied with one M20 blanking plug.
•	 Easy connection to wire and disconnect with plug-in 	
terminal blocks.
•	 Bi-pin (G13) 18 & 36 W magnetic ballast versions operate at 	
158°F/70°C ambient temperature with T4 rating.
•	 Magnetic ballast versions 230 V 50 Hz or 240 V 50 Hz or 220 V 	
60 Hz or 230 V 60 Hz.
•	 Electronic ballast versions 110 to 254 Vac/Vdc 50/60 Hz.
•	 3 hour emergency version with automatic self test every month
•	 Plug in battery pack (6 V 4 Ah) is easy to remove for
maintenance.

Lighting

Standard Materials
•	
•	
•	
•	
•	

End caps and cover: gray painted Zamak
Glass tube: borosilicate
O-ring gasket: Nitrile (NBR)
Internal reflector: white powder coated galvanized steel
Mounting accessories: several accessories in different material
such as zinc plated steel, galvanized steel or 316 stainless steel

Options
•	 3 lamp versions.
•	 8 W fluorescent (Bi-pin G5) available, see section HBDC series.

1262

2 x 36 W

2 x 18 W

Certifications and Compliances
•	
•	
	
	
	
•	
	
	
	
•	
•	
•	
•	
•	
•	
•	
•	
•	
•	
•	
•	

Certification Type: FLd
Zone 1 and 2
— Conforming to ATEX 94/9/CE: CE 0081
II 2 G
— ATEX/IEC Protection: Ex d IIB, Ex d IIB+H2, Ex d IIC
— T Rating: (See table)
Zone 21 and 22
II 2 D
— Conforming to ATEX 94/9/CE: CE
— ATEX/IEC Protection: Ex tD A21
— Surface Temperature: (See table)
Ambient Temperature: -4°F to 131°F / -20°C to 55°C
CE Declaration of Conformity: 50203
ATEX Certificate: LCIE 97 ATEX 6012
IECEx Certificate: IECEx LCI 04.0018
Other Certifications: GOST
Index of Protection (solid & liquid): IP66/68
Impact Resistance (shock): IK08
Internal Volume: > 122.05in3/2 dm3 (2 liters)
Ex Standards: EN / IEC 60079-0; 60079-1; 61241-0; 61241-1
Product Standards: EN / IEC 60598-1; 60598-2-22
EMC Standards: EN / IEC 55015; 61547
Other Standards: EN / IEC 60529 (IP); 62262 (IK)

Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

FD Series Cylindrical Fluorescent Luminaires

Standard and Emergency Battery Back-Up – Flameproof
Zone 1 & 2 – 21 & 22
II 2 GD
ATEX / IECEx
IP66/68

Ordering Information
Order using catalog numbering guide below or select catalog number from tables on following pages.
Catalog Numbering Guide For Fd Non-Metallic Fluorescent Lighting Fixtures
FD

B

Series:
FD - FD Series
Zone 1 & 2 - 21 & 22
ATEX / IEC certified

1

18

Number of Lamps:
1 - Single
2 - Double
3 - Three Lamps

BK

A

P

Options:
(Options must be
listed alphabetically)
E - 3h Emergency
(combined) –
Battery 6 V 4 Ah

Emergency versions:
BU - 110 to 254 Vac/Vdc
50/60 Hz
Lamp Type:
B - Bi-pin (G13) Fluorescent
C - Compact Fluorescent (2G11)
F - Bi-pin (G5) Fluorescent

Cable Entry:
M - Metric M20
N - NPT 3/4"

Wattage:
18 - 18 Watt
36 - 36 Watt
58 - 58 Watt

T Rating (Gas) and Surface Temperature (Dust) Table

Model
0.3

1.2

1.5

Dust – Surface Temperature
Without
External
Reflector

With
External
Reflector

Compact Fluorescent 2G11
18 W max.

T6

T5

N.A.

T5

T4

203 °F/95 °C 266 °F/130 °C

a) Fluorescent G13 	
Magnetic Ballast
1 x 18 W / 2 x 18 W

T6

T5

T4

T6

T5

207 °F/97 °C 203 °F/95 °C

b) Fluorescent G13
Electronic Ballast
1 x 18 W / 2 x 18 W / 3 x 18 W

T6

T6

N.A.

T6

T5

172 °F/78 °C 203 °F/95 °C

c) Compact Fluorescent 2G11
1 x 36 W
2 x 36 W

T6

T5

N.A.

T6
T5

T4

203 °F/95 °C 266 °F/130 °C

a) Fluorescent G13
Magnetic Ballast
1 x 36 W / 2 x 36 W / 3 x 36 W

T6

T5

T4

T6

T5

230 °F/110 °C 203 °F/95 °C

b) Fluorescent G13
Electronic Ballast
1 x 36 W / 2 x 36 W / 3 x 36 W

T6

T6

N.A.

T6

T6

172 °F/78 °C 176 °F/80 °C

a) Fluorescent G13
Magnetic Ballast
1 x 58 W / 2 x 58 W

T6

T6

N.A.

T6

T5

176 °F/80 °C 203 °F/95 °C

b) Fluorescent G13
Electronic Ballast
1 x 58 W / 2 x 58 W / 3 x 58 W

T6

T5

N.A.

T6

T5

183 °F/84 °C 203 °F/95 °C

Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

1263

Lighting

0.6

Lamp Type

Gas – T Rating
Without External Reflector
With External Reflector
Ta =
Ta =
Ta =
Ta =
Ta =
104° F/40° C 131 °F/55 °C 158 °F/70 °C 104 °F/40 °C 131 °F/55 °C

Lighting: Explosionproof — Area — Fluorescent

Voltage (50/60 Hz):
Standard versions:
AA - 220 Vac 60 Hz
AC - 230 Vac 60 Hz
XC - 230 Vac 50 Hz
X3 - 240 Vac 50 Hz
BU - 110 to 254 Vac/Vdc
50/60 Hz

FD Series Cylindrical Fluorescent Luminaires

Standard and Emergency Battery Back-Up – Flameproof
Zone 1 & 2 – 21 & 22
II 2 GD
ATEX / IECEx
IP66/68

Ordering Information – Standard Versions
Two M20 threaded entries, supplied with one M20 aluminum blanking plug.
Connection via 1 x 3 double deck terminals.
Capacity (flexible/solid): 0.001 in2 to 0.004 in2 / 0.75 mm2 to 2.5 mm2.

L

For Bi-pin (G13) Fluorescent Lamps - T8 (1.02"/26 mm) or T12 (1.50"/38 mm)
230 V - 50 Hz – Magnetic Ballast – Starter Ignition
Compensated power supply – power factor > 0.9

L

Lighting: Explosionproof — Area — Fluorescent

No. of
Lamps

Power
(W)

Gas
Group

Model

L
N

N

N

Weight
(lbs/kg)

Volume
(in3/dm3)

Pack

Catalog
Number

1

18

IIC

0.6

19.8/9

3539.38/58

1

FDB118XCM

2

18

IIC

0.6

21.38/9.7

3539.38/58

1

FDB218XCM

1

36

IIB+H2

1.2

32.41/14.7

6041.35/99

1

FDB136XCM

2

36

IIB+H2

1.2

33.73/15.3

6041.35/99

1

FDB236XCM

1

58

IIB

1.5

37.48/17

7261.83/119

1

FDB158XCM

2

58

IIB

1.5

40.12/18.2

7261.83/119

1

FDB258XCM

240 V - 50 Hz – Magnetic Ballast – Starter Ignition
Compensated power supply – power factor > 0.9
1

18

IIC

0.6

19.8/9

3539.38/58

1

FDB118X3M

2

18

IIC

0.6

21.38/9.7

3539.38/58

1

FDB218X3M

1

36

IIB+H2

1.2

32.41/14.7

6041.35/99

1

FDB136X3M

2

36

IIB+H2

1.2

33.73/15.3

6041.35/99

1

FDB236X3M

1

58

IIB

1.5

37.48/17

7261.83/119

1

FDB158X3M

2

58

IIB

1.5

40.12/18.2

7261.83/119

1

FDB258X3M

3539.38/58

1

FDB218AAM

220 V - 60 Hz – Magnetic Ballast – Starter Ignition

Lighting

Compensated power supply – power factor > 0.9
2

18

IIC

0.6

21.38/9.7

2

36

IIB+H2

1.2

33.73/15.3

6041.35/99

1

FDB236AAM

2

58

IIB

1.5

40.12/18.2

7261.83/119

1

FDB258AAM

230 V - 60 Hz – Magnetic Ballast – Starter Ignition
Compensated power supply – power factor > 0.9

1264

2

18

IIC

0.6

21.38/9.7

3539.38/58

1

FDB218ACM

2

36

IIB+H2

1.2

33.73/15.3

6041.35/99

1

FDB236ACM

2

58

IIB

1.5

40.12/18.2

7261.83/119

1

FDB258ACM

Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

FD Series Cylindrical Fluorescent Luminaires

Standard and Emergency Battery Back-Up – Flameproof
Zone 1 & 2 – 21 & 22
II 2 GD
ATEX / IECEx
IP66/68

Ordering Information – Standard Versions – Continued

L

For Bi-pin (G13) Fluorescent Lamps - T8 (1.02"/26 mm) or T12 (1.50"/38 mm)
110 to 254 Vac/Vdc 50/60 Hz – Electronic Ballast
Power factor > 0.95	

L

L
N

N

N

Power
(W)

Gas
Group

Model

Weight
(lbs/kg)

Volume
(in3/dm3)

Pack

Catalog
Number

2

18

IIC

0.6

21.38/9.7

3539.38/58

1

FDB218BUM

2

36

IIB

1.2

33.73/15.3

6041.35/99

1

FDB236BUM

3

36

IIB

1.2

35.94/16.3

6041.35/99

1

FDB336BUM

1

58

IIB

1.5

37.48/17

7261.83/119

1

FDB158BUM

2

58

IIB

1.5

40.12/18.2

7261.83/119

1

FDB258BUM

3

58

IIB

1.5

42.33/19.2

7261.83/119

1

FDB358BUM

For 2G11 Compact Fluorescent Lamps – TC-L
230 V - 50 Hz  –  Magnetic Ballast – Starter Ignition
Compensated power supply – power factor > 0.9 – Lamps supplied
1

18

IIC

0.3

19.8/9

3539.38/58

1

FDC118XCM

2

18

IIC

0.3

21.38/9.7

3539.38/58

1

FDC218XCM

1

36

IIB+H2

0.6

32.41/14.7

6041.35/99

1

FDC136XCM

2

36

IIB+H2

0.6

33.73/15.3

6041.35/99

1

FDC236XCM

Emergency Versions
Two M20 threaded entries, supplied with one M20 aluminum blanking plug.
Connection via 1 x 4 double deck terminals.
Capacity (flexible/solid): 0.001 in2 to 0.004 in2 / 0.75 mm2 to 2.5 mm2.

Lighting

For Bi-pin (G13) Fluorescent Lamps – T8 (1.02"/26 mm) or T12 (1.50"/38 mm)
110 to 254 Vac/Vdc 50/60 Hz –  Electronic Ballast
3 hour duration - battery pack 6 V 4 Ah - Power factor > 0.95 - 	
Self test every month.
No. of
Lamps

Power
(W)

Gas
Group

Model

Line
Output

Weight
(lbs/kg)

Volume
(in3/dm3)

Pack

Catalog
Number

2

18

IIC

0.6

29%

25.57/11.6

3539.38/58

1

FDB218BUME

2

36

IIB

1.2

16%

37.92/17.2

6041.35/99

1

FDB236BUME

2

58

IIB

1.5

11%

44.53/20.2

7261.83/119

1

FDB258BUME

Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

Lighting: Explosionproof — Area — Fluorescent

No. of
Lamps

1265

FD Series Cylindrical Fluorescent Luminaires

Standard and Emergency Battery Back-Up – Flameproof
Zone 1 & 2 – 21 & 22
II 2 GD
ATEX / IECEx
IP66/68
	
Description

Pack

Catalog Number

1

FDER1G

External Reflector – White Painted Galvanized Steel
Model 0.3
Model 0.6

1

FDER2G

Model 1.2

1

FDER3G

Model 1.5

1

FDER4G

1

FDPG1Z

Protective Guard – Zinc Plated Steel

Lighting: Explosionproof — Area — Fluorescent

Model 0.3
Model 0.6

1

FDPG2Z

Model 1.2

1

FDPG3Z

Model 1.5

1

FDPG4Z

Zinc plated steel

1

FDFBZ

316 stainless steel

1

FDFBS

Zinc plated steel

1

FDSBZ

316 stainless steel

1

FDSBS

Zinc plated steel

1

FDHC49Z

316 stainless steel

1

FDHC49S

Fixing Brackets for Ease of Surface Installation – Set of Two

Surface Mounting Brackets – Set of Two

Half Clamp Brackets for Pole Mounting – Set of Two
Dia. 1.65 to 1.93" / 42 to 49 mm pole 	
(1.25 to 1.5" / 31.8 to 38.1 mm tube)

Lighting

Dia. 2.36"/60 mm pole (2"/50.8mm tube)
Zinc plated steel

1

FDHC60Z

316 stainless steel

1

FDHC60S

1.20 M stainless steel chain

1

FDSCS

Fall Prevention Kit

1266

Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

FD Series Cylindrical Fluorescent Luminaire Technical Data

Standard and Emergency Battery Back-Up – Flameproof
Zone 1 & 2 – 21 & 22
II 2 GD
ATEX / IECEx
IP66/68

Wiring Diagram

Emergency Function Diagram
Two Lamp Version

Mains
PE	

N	

L

Mains
Lighting
Switch

Lighting Switch ON

Lighting Switch OFF

ON

L1

Standard Fluorescent
Lighting Fixture

L1
L
N
PE

Emergency Fluorescent
Lighting Fixture

OFF

Lighting: Explosionproof — Area — Fluorescent

L
N
PE

LED Status
Color

Indication
Blinking 1:1

Green

Red

ON

Mains good, battery trickle charging

Blinking 1:1

No battery connected or something is defective

Flashing 1:1

Mains faulty, battery empty or lamp defective

ON

Mains faulty, output ON

OFF

No mains, battery completely empty

Blinking 1:1

Mains good, performing self test

ON

Result of self test was not good

Lighting

Yellow

Function
Mains good, battery quick charging

Dimensions (in/mm)
0.47”/
12.0 mm

0.59”/
15.0 mm

3.05”/
77.5mm

Model

A

B

0.3

16.93" / 430 mm

13.19" / 335 mm

0.6

29.33" / 745 mm

25.59" / 650 mm

1.2

53.74" / 1365 mm

49.61" / 1260 mm

1.5

65.16" / 1655 mm

61.42" / 1560 mm

3.50”/
3.35”/
89.0 mm 85.0 mm

Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

1267

FD Series Cylindrical Fluorescent Luminaire Photometric Data

Standard and Emergency Battery Back-Up – Flameproof

Photometric Data
Polar curves for a 1000 lm flux, according to NF C 71-120
Luminaire symbol according to NF C 71-121

Longitudinal
Transverse

Bi-pin (G13) Fluorescent
1 x 18 W
Efficiency 75.3%
NF C 71-121/0: 0.69 H + 0.06 T

Lighting

Lighting: Explosionproof — Area — Fluorescent

Candela
Distribution
0
5
10
15
20
25
30
35
40
45
50
55
60
65
70

0-180 90-270 150°	 120°
167
167
Degrees
166
167
164
168
160
168
154
168
147
168
139
167
129
166
118
164
151
162
106
160
77
157
61
152
45
144 0°	
15°
28
135

105°
90°
75°
60°
45°

30°

105°
90°
75°
60°
45°

30°

1 x 58 W
Efficiency 74.5%
NF C 71-121/0: 0.70 H + 0.05 T

0-180 90-270
167
167 150°	 120°
167
167
Degrees
164
167
160
167
154
167
147
166
139
165
130
164
119
163
106
161
93
158
78
155
63
149 0°	
15°
47
142
31
132

1268

0-180 90-270 150°	 120°
161
161
Degrees
160
162
157
163
153
164
148
164
141
164
133
164
123
163
112
130
100
153
86
147
73
141
58
134
41
121 0°	
15°
26
106

105°
90°
75°
60°
45°

30°

Candela
Distribution
0-180 90-270 150°	 120°
0
149
149
Degrees
5
148
149
10
146
150
15
142
150
20
137
150
25
131
149
30
124
148
35
114
146
40
104
144
45
93
138
50
81
131
55
68
125
60
54
117
65
40
105 0°	
15°
70
26
91

105°
90°
75°
60°
45°

30°

Candela
Distribution
0-180 90-270
0
148
148 150°	 120°
5
147
149
Degrees
10
145
148
15
142
149
20
137
150
25
131
149
30
124
148
35
115
146
40
105
144
45
94
140
50
82
134
55
69
128
60
55
119 0°	
15°
65
42
108
70
28
95

0
5
10
15
20
25
30
35
40
45
50
55
60
65
70

Candela
Distribution

0-180 90-270 165°	 135°	120°
141
141
Degrees
105°
141
141
141
139
90°
140
135
75°
139
130
138
124
60°
136
117
133
109
45°
128
100
121
89
113
77
105
65
30°
96
51
15°
87
38 0°	
78
25

3 x 36 W
Efficiency 53.3%
NF C 71-121: 0.47 G + 0.06 T

105°
90°
75°
60°
45°

30°

2 x 36 W
Efficiency 61.5%
NF C 71-121: 0.57 G + 0.04 T

Candela
Distribution
0
5
10
15
20
25
30
35
40
45
50
55
60
65
70

0
5
10
15
20
25
30
35
40
45
50
55
60
65
70

2 x 18 W
Efficiency 56.2%
NF C 71-121: 0.52 G + 0.04 T

Candela
Distribution

2 x 36 W
Efficiency 61.5%
NF C 71-121: 0.57 G + 0.04 T

Candela
Distribution
0-180 90-270 150°	 120°
164
164
Degrees
163
164
161
165
157
165
151
165
145
165
137
165
127
164
116
162
104
160
91
158
76
154
61
149
45
140 0°	
15°
30
131

3 x 18 W
Efficiency 57%
NF C 71-121: 0.50 G + 0.07 T

Candela
Distribution

1 x 36 W
Efficiency 74.3%
NF C 71-121/0: 0.69 H + 0.05 T

0
5
10
15
20
25
30
35
40
45
50
55
60
65
70

2G11 Compact Fluorescent

2 x 18 W
Efficiency 68.1%
NF C 71-121: 0.63 G + 0.06 T

0
5
10
15
20
25
30
35
40
45
50
55
60
65
70

0-180 90-270 150°	 120°
154
154
Degrees
153
154
151
154
147
153
142
153
136
152
128
150
119
147
108
142
95
143
81
127
66
113
49
101
32
88 0°	
15°
17
75

105°
90°
75°
60°
45°

30°

2 x 36 W
Efficiency 53.6%
NF C 71-121: 0.50 G + 0.04 T

Candela
Distribution
0-180 90-270 165°	 135°	120°
0
132
132
Degrees
105°
5
132
131
10
132
129
90°
15
131
126
75°
20
131
122
25
131
116
60°
30
128
110
35
125
102
45°
40
120
93
45
114
83
50
107
72
55
99
61
30°
60
91
49
15°
65
82
36 0°	
70
74
24

Candela
Distribution
0-180 90-270 150°	 120°
0
140
140
Degrees
5
139
141
10
137
141
15
134
142
20
129
141
25
124
140
30
117
139
35
109
137
40
99
132
45
89
125
50
77
117
55
65
108
60
52
97
65
38
87 0°	
15°
70
24
75

105°
90°
75°
60°
45°

30°

3 x 36 W
Efficiency 53.3%
NF C 71-121: 0.47 G + 0.06 T

105°
90°
75°
60°
45°

30°

Candela
Distribution
0-180 90-270
0
125
125 165°	 135°	120°
5
125
125
Degrees
10
125
124
15
124
122
20
123
119
25
121
114
30
118
108
35
115
101
40
109
92
45
103
82
50
96
72
55
89
60
60
81
48 0°	
15°
65
73
36
70
65
24

105°
90°
75°
60°
45°

30°

Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

Code•Master™ Incandescent Factory Sealed Luminaires
Explosionproof, Dust-Ignitionproof
For use with threaded metal conduit.

NEC:
Class I, Division 1, Groups C, D
Class II, Division 1 and 2, Groups E, F, G
Class III
NEMA 3R, 4X

CEC: V
Class I, Division 1 and 2, Groups B, C, D. T3B
Class I, Zone 1 and 2, Groups IIB, IIA
Exd IIB + H2, Zone 1
Class II, Division 1 and 2, Groups E, F, G. T3B
Class III

Type 3R, 4X

Applications
•	 Code•Master Incandescent Explosionproof fixtures are
designed to provide safe operation in the presence of hazardous
gases, vapors, or dusts, defined by the National Electrical Code
as Class I, Groups C and D; Class I, Zone 1, Group IIB; and
Class II, Groups E, F and G.
•	 For use in hazardous locations such as plants where plastics,
paints, thinners and petrochemicals are manufactured.
•	 For use in chemical and petrochemical plants, such as
manufacturers of plastics, paints and thinners, in refineries,
and in other areas where ignitable vapors, dust, moisture and
corrosive elements may be present.
•	 Suitable for outdoor saltwater locations and for other 	
wet locations.

Features

Standard Materials
•	 Fixture housing, mounting hoods and guards: copperfree 	
(4/10 of 1% max.) aluminum
•	 Globes: prismatic glass
•	 Reflectors: fiberglass reinforced polyester

Standard Finishes
•	 Fixture housing, guards and mounting hoods: epoxy power 	
coat finish, electrostatically applied for complete, uniform
corrosion protection

Options
•	 Add suffix -Z for Exd IIB + H2, Zone 1 V.

Certifications and Compliances
•	 UL Standard: UL 1598, UL 1598A, UL 844
•	 UL Listed: E10444

Lighting

V CSA Certification only.
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

Lighting: Explosionproof — Area — Incandescent

•	 Fixtures operate safely in high ambient temperatures.
•	 Patented “wireless” design. Threading of fixture unit 	
onto mounting hood makes electrical connection. The
	 only wiring required is attaching two wires to connection
	 block in mounting hood.
•	 Connection block is easily wired: (a) loosen two screws; (b)
make wire connections; and (c) re-position connection block.
•	 Safe, easy servicing without disconnecting any wiring.
“Wireless” fixture unit threads off mounting hood for convenient
servicing or for immediate replacement with a “stand-by” unit.
•	 Acme double-lead threads speed installation and fixture removal
from mounting hood – only half as many turns are required
as for single-lead threads. The threads do not stick or gall,
eliminating problems often encountered with single-lead threads
during fixture unit removal.
•	 Strategic location of lamp socket, in combination with interior
prism design of the glass globe, provides optimum light
distribution and control.
•	 Heat- and impact-resistant globes have smooth 	
dust-resistant exterior.
•	 Superior corrosion resistance, with epoxy powder coat finish.
•	 Porcelain socket with nickel-plated phosphor bronze screw
shell. Assures long trouble-free operation in high ambient areas.
•	 Choice of mountings: pendant, ceiling, bracket and stanchion.
•	 Fiberglass-reinforced polyester reflectors, in standard dome
or 30° angle styles, are ideal in installations where luminaire is
subject to exceptionally severe corrosive atmospheres.
•	 All threaded joints are flame-tight.
•	 Heat- and impact-resistant globes have smooth 	
dust-resistant exterior.
•	 Superior corrosion resistance, with epoxy powder coat finish.
•	 Optional guards protect globes from damage. Secured to fixture
with three stainless steel screws.
•	 Medium base lamp socket.
•	 Maximum voltage 300 Vac 60 Hz.

1269

Code•Master™ Incandescent Factory Sealed Luminaires
Explosionproof, Dust-Ignitionproof
For use with threaded metal conduit.

NEC:
Class I, Division 1, Groups C, D
Class II, Division 1 and 2, Groups E, F, G
Class III
NEMA 3R, 4X

Class III
Type 3R, 4X

CEC: V
Class I, Division 1 and 2, Groups B, C, D. T3B
Class I, Zone 1 and 2, Groups IIB, IIA
Exd IIB + H2, Zone 1
Class II, Division 1 and 2, Groups E, F, G. T3B

Order using catalog numbering guide below or select catalog number from tables on following pages.
Catalog Numbering Guide
CI

P

30

Series:
CI – Code•Master Incandescent

75

Wattage:
30 – 100 W A21	
        200 W A23	
        300 W PS25

Options:
G – Guard
Blank – No Guard
Z - Exd IIB + H2, Zone 1 V

Lighting: Explosionproof — Area — Incandescent

Mounting Hood:
P – Pendant
B – Wall Bracket
C – Ceiling
S – Stanchion

Lighting

G

Hub Size:
75 – 3/4”
100 – 1”
150 – 1-1/4” or 1-1/2”

Technical Data Thermal Suitability of Code•Master Incandescent Fixture.
Lamp Type

Lamp Watts
(Max.)

Use Wire Supply
°F/°C

Ambient
Temperature
°F/°C

Incandescent (A21)

100

167/75

104/40

T5

T3C

Incandescent (A23)

200

167/75

104/40

T4

T3C

Incandescent (PS25)

300

167/75

104/40

T3C

T3C

Class I, Division 1,
Groups C & D

Class II, Division 1,
Groups E, F & G

“T” Numbers Represent the Maximum External Temperature for Class I, Division 1 Locations and
Maximum Surface Temperature Under Dust Blanket for Class II, Division 1 Locations.
“T”
Number

T1

350

325

T2

T2A

T2B

T2C

T2D

T3

T3A

T3B

T3

T4

T4A

T5

T6

Temp
Range
(°F)

664842

619662

574617

538572

502536

448500

421446

394419

358392

331356

322329

277320

250275

214248

187212

185

Temp
Range
(°C)

351450

326350

301325

281300

261280

231260

216230

201215

181200

166180

161165

136160

121135

101120

86100

85

NOTE: The maximum operating temperature of the fixture must not exceed the ignition temperature of the gas, vapor or dust to be encountered per the National
Electrical Code and the Canadian Electrical Code..

V CSA Certification only.

1270

Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

Code•Master™ Incandescent Factory Sealed Luminaires
Explosionproof, Dust-Ignitionproof
For use with threaded metal conduit.

NEC:
Class I, Division 1, Groups C, D
Class II, Division 1 and 2, Groups E, F, G
Class III
NEMA 3R, 4X

CEC: V
Class I, Division 1 and 2, Groups B, C, D. T3B
Class I, Zone 1 and 2, Groups IIB, IIA
Exd IIB + H2, Zone 1
Class II, Division 1 and 2, Groups E, F, G. T3B
Class III

Type Mounting

Type 3R, 4X

Hub Size (Inches)

Catalog Number ➌

Pendant
CIP3075

3/4
One Hub
Rigid Conduit.

CIP30100 ➋

1
Ceiling
Four Hubs
Three Close-Up Plugs
Rigid Conduit

CIC3075

3/4

CIC30100 ➋

1

Wall Bracket
Four Hubs
Three Close-Up Plugs
Rigid Conduit

CIB3075

3/4

1

CIB30100 ➋

One Hub

1-1/2 ♦

CIS30150

Mounting Hoods
Type Mounting

Hub Size (Inches)

Hood Weight (Lbs.)

Catalog Number

Pendant
3/4

2/.9

CAP75

1

2/.9

CAP100 ➋

Four Hubs
Three Close-Up Plugs
Rigid Conduit

3/4

4/1.8

CAC75

1

4/1.8

CAC100 ➋

Four Hubs
Three Close-Up Plugs
Rigid Conduit

3/4

6/2.7

CALB75

1

6/2.7

CALB100 ➋

1-1/4 or 1-1/2 ➊

2/.9

CAS-150 ➊

One Hub
Rigid Conduit
Ceiling

Lighting: Explosionproof — Area — Incandescent

25° Stanchion

Bracket

One Hub
➊ 1-1/2” Tapped hub furnished with 1-1/2” to 1-1/4” reducer.
➋ 1” Hubs are listed for Group D only.
➌ Catalog numbers shown are supplied with clear lens. Add suffix G for optional Guard.
V CSA Certification only.
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

1271

Lighting

25° Stanchion

Code•Master™ Incandescent Factory Sealed Luminaire Fixture Units and Accessories
Explosionproof, Dust-Ignitionproof
For use with threaded metal conduit.

NEC:
Class I, Division 1, Groups C, D
Class II, Division 1 and 2, Groups E, F, G
Class III
NEMA 3R, 4X

CEC: V
Class I, Division 1 and 2, Groups B, C, D. T3B
Class I, Zone 1 and 2, Groups IIB, IIA
Exd IIB + H2, Zone 1
Class II, Division 1 and 2, Groups E, F, G. T3B
Class III

Description

Weight lbs/kg

Type 3R, 4X

Catalog Number

Fixture Unit Only

Not including mounting
hood

11/5

CJNC30I

Optional White Polyester Reflector
Standard Dome

2.5/1.1

KR2-ST

Angled Reflector

2.5/1.1

KR2-AN

0.5/.2

CJGU-15

7.5/3.4

CJEXRN

0.5/.2

VPT-7

Optional White Polyester Reflector

Optional Three Way Exit Sign

Replacement Connection Block

Lighting

Lighting: Explosionproof — Area — Incandescent

Optional Aluminum Guard

1272

Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

Code•Master™ Incandescent Factory Sealed Luminaire Family Tree and Dimensions
Explosionproof, Dust-Ignitionproof
For use with threaded metal conduit.

NEC:
Class I, Division 1, Groups C, D
Class II, Division 1 and 2, Groups E, F, G
Class III
NEMA 3R, 4X

Type 3R, 4X

CEC: V
Class I, Division 1 and 2, Groups B, C, D. T3B
Class I, Zone 1 and 2, Groups IIB, IIA
Exd IIB + H2, Zone 1
Class II, Division 1 and 2, Groups E, F, G. T3B
Class III

Ceiling
Four Hubs
Three Close-Up Plugs
3/4” NPT
CAC75

Pendant
One Hub
3/4” NPT
CAP75

Bracket
Four Hubs
Three Close-Up Plugs
3/4” NPT
CALB75

25° Stanchion
One Hub
1-1/4 or 1-1/2” NPT
CAS150

Code•Master
Incandescent
Fixture Unit
CJNC30I

Standard Dome
KR2-ST

Angle Reflector
KR2-AN

Optional Three Way
Exit Sign
CJEXRN

Dimensions in Inches/Millimeters
Hub for .75"
NPT Conduit

Pendant
13.88"/
352.6 mm

4.50"/
114.3 mm

Wall Bracket

3.75"/
95.3 mm

4.92"/
125.0 mm

12.38"/
314.5 mm

Hub For
0.41"/
10.4 mm Dia.

13.15"/
334.0 mm

3/4” NPT
2.46"/
62.5 mm

2.28"/
57.9 mm

2” Wiring access

13.53"/
343.7 mm

3.92"/
99.6 mm

13.75"/
349.3 mm

cover both sides.
4.25"/
108.0 mm

4.92"/
125.0 mm Sq.
1.23"/
31.2 mm
3.46"/
87.9 mm

1.79"/
45.5 mm

11.5"/
292.1 mm

7.80"/
198.1 mm

13.75"/
349.3 mm

Ceiling

25° Stanchion

5.95"/
151.3 mm
7.80"/
198.1 mm

4.00"/
101.6 mm

4.00"/
101.6 mm

4.00"/
101.6 mm

25˚

Hub for .75" NPT
Conduit Four Sides

Lighting

13.38"/
339.9 mm

11.93"/
303.0 mm

13.00"/
330.2 mm

12.87"/
326.9 mm

4.50"/
114.3 mm
Dia.

5.92"/
150.4 mm

7.80"/
198.1 mm

11.43"/
290.3 mm
12.48"/
317.0 mm

V CSA Certification only.
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

Lighting: Explosionproof — Area — Incandescent

Optional Aluminum
Guard
CJGU-15

1273

A-51® Incandescent Factory Sealed Luminaires
Explosionproof

Suitable for use in Wet Locations. UNILETS for use with Threaded Metal Conduit.
For Group A and B
Class I, Division 1 and 2, Groups A , B, C, D
Class II, Division 1 and 2, Groups E, F, G
Class III

For Group C and D
Class I, Division 1 and 2, Groups C, D
Class II, Division 1 and 2, Groups E, F, G*
Class III

Applications

Group A and B

•	 A-51 Series Incandescent Class I, Groups A, B, C and D; and
Class II, Groups E, F and G applications (see listings and area
suitability chart).
•	 Ideal for use in chemical and petrochemical plants, and in other
heavy process areas where ignitable vapors, dust, moisture and
corrosive atmospheres may be present.
•	 Suitable for use in wet locations.
•	 Wide range of wattages – 60 W through 500 W 	
incandescent lamps.
•	 Choice of units with or without guard, as well as choice of
porcelain, polyester or aluminum reflectors.
•	 Choice of mountings: pendant, ceiling, 25° stanchion, long
bracket and 15° short bracket.
•	 Porcelain reflectors for standard applications and fiberglass
reinforced polyester reflectors for installations where fixture is
subject to exceptionally severe corrosive atmospheres. High
bay reflector for installations where mounting height from work
plane ranges from 20 to 30 feet/508" to 762 mm.
•	 Class I, Groups A and B fixtures have special UL-approved
sintered metal flame arrester.

Polyester Reflector

Porcelain Reflector

Group C and D

Lighting

Lighting: Explosionproof — Area — Incandescent

Features
•	 All A-51 fixtures are factory-sealed; no external sealing 	
fittings required.
•	 New high temperature phenolic connection block in mounting
hood has rugged leaf spring contacts – loosen two screws,
rotate and remove for quick wiring.
•	 Safe, easy servicing or relamping without disconnecting any
wiring. “Wireless” fixture unit easily threads off mounting hood
for convenient servicing or for immediate exchange with “standby” unit.
•	 All joints are flame-tight.
•	 Specially formulated two-coat baked epoxy enamel provides
superior protective finish to resist corrosion. Applied to all
mounting hoods, fixture units and guards.
•	 New high temperature glass-reinforced phenolic socket 	
block in fixture unit has collector ring and pin that automatically
make electrical contact as fixture unit is threaded onto
mounting hood.
•	 Globes in A-51 fixtures are explosionproof and heat- and
impact-resistant glass. Prismatic configuration on globe 	
interior provides light control while allowing smooth exterior
surface for cleaning.
•	 A-51 fixture units have standardized threads to fit all A-51 	
and mounting hoods.
•	 All fixtures have aluminum inner reflector for increased lumen
efficiency.
•	 A-51 fixture guards to protect globe are of rugged copperfree
aluminum construction and double epoxy coated. Easily mount
to globe ring with 3 screws.

Polyester Reflector

Porcelain Reflector

Standard Finishes
•	 Fixtures, guards and mounting hoods: two-coat epoxy-clad
finish. Epoxy powder coat finish, electrostatically applied for
complete, uniform surface protection.
•	 Steel reflectors: white porcelain enamel.
•	 Polyester and aluminum reflectors: natural finish.

Certifications and Compliances
•	
•	
•	
•	

UL Standard: UL 1598, UL 844
UL Listed: E10444
CSA Standard: C22.2 No. 250, C22.2 No. 137
CSA Certified: 025428

Standard Materials
•	 Fixtures and guards: copperfree (4/10 of 1% max.) aluminum.
•	 Pendant mounting hoods: copperfree (4/10 of 1% max.)
aluminum.
•	 Ceiling and bracket mounting hoods: malleable iron with
aluminum adapters.
•	 Reflectors: porcelain-enameled steel, aluminum or fiberglass
reinforced polyester.

1274

Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

A-51® Incandescent Factory Sealed Luminaires
Explosionproof

Suitable for use in Wet Locations. UNILETS for use with Threaded Metal Conduit.
Class I, Division 1 and 2, Groups A, B, C, D.
Class II, Division 1 and 2, Groups E, F, G
Class III

Illustrated Features

Weights
Fixture Units
Catalog Number

Wt. lbs/kgs

AAU-1N

7.6/3.4

AAU-15N

7.6/3.4

AAU-2NS

10.7/4.9

AAU-5NS

20.3/9.2

AAUA-15

15.0/6.8

AAUA-2

18.0/8.2
Mounting Hoods

Type

Wt. lbs/kg

Pendant

1.3/.6

Ceiling

4.8/2.2

Stanchion

1.6/.7

Long Bracket

8.9/4.0

Short Bracket

4.8/2.2

Lighting: Explosionproof — Area — Incandescent

Guards
Catalog Number

Wt. lbs/kgs

AAGU-1

0.4/.2

AAGU-2

0.8/.4

AAGU-5

1.9/.9

AAGUA-15

0.5/.2
Standard Reflectors

Catalog Number

Wt. lbs/kgs

AARP-2ST

2.8/1.3

AARW-15ST

2.1/1.0

AARW-2ST

2.9/1.3

AARW-5ST

4.3/2.0

AARW-15ST

2.1/1.0
30˚° Angle Reflectors
Wt. lbs/kgs

AARP-2AN

3.3/1.5

AARW-15AN

2.1/1.0

AARW-2AN

2.4/1.1

AARW-5AN

7.0/3.2

AARW-15AN

2.1/1.0

Lighting

Catalog Number

High Bay Reflectors

Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

Catalog Number

Wt. lbs/kgs

AARE-2HB

2.9/1.3

AARE-5HB

3.9/1.8

1275

A-51® Incandescent Factory Sealed Luminaire Classified Area Suitability
Explosionproof

Suitable for use in Wet Locations. UNILETS for use with Threaded Metal Conduit.
Class I, Division 1 and 2, Groups A, B, C, D.
Class II, Division 1 and 2, Groups E, F, G
Class III

Fixture
Unit

Lamp
Watts

Without
Reflectors

Standard
Dome

30°˚
Angle

High
Bay

Supply Wire
°F/°C

Class I Division 1 and Division 2 Groups C and D
AAU1N
AAU15N

AAU2NS

100 W A19

T5

T5

T5

—

257/125

100 W A21

T5

T5

T5

—

257/125

150 W A23

T3C

T3C

T3C

—

257/125

200 W A25

T3C

T3C

T3C

—

257/125

200 W PS25

T3C

T3C

T3C

—

257/125

300 W PS25

T3C

T3A

T3A (D)

—

257/125

200 W PS25

T3C

T3C

T3C

—

230/110

200 W PS30

T3C

T3C

T3C

—

230/110

300 W PS25

T3C

T3C

T3C

—

230/110

300 W PS30

T3C

T3C

T3C

—

230/110

Class I Division 1 and Division 2 Groups A †, B, C and D

Lighting: Explosionproof — Area — Incandescent

AAUA15

AAUA2

150 W A23

T3C

T3C

T3C

—

230/110

150 W A25

T3C

T3C

T3C

—

230/110

200 W A25

T3C

T3C

T3C

—

230/110

200 W PS25

T3C

T3C

T3C

—

230/110

200 W PS25

T3C

T3C

T3C

—

230/110

200 W PS30

T3C

T3C

T3C

—

230/110

300 W PS25

T3C

T3C

T3C

—

230/110

300 W PS30

T3C

T3C

T3C

—

230/110

T3C

T3C

—

257/125

Class II Division 1 and Division 2 Groups E, F and G
AAU1N

100 W A19
100 W A21

T3C

T3C

T3C

—

257/125

AAU15N

150 W A23

T3C

T3C

T3C

—

257/125

200 W A25

T3C

T3C

T3C

—

257/125

200 W PS25

T3

T3

T3

—

257/125

300 W PS25

T3

—

—

—

257/125

Lighting

AAU2NS

T3C

200 W PS25

T3C

T3C

T3C

—

230/110

200 W PS30

T3C

T3C

T3C

—

230/110

300 W PS25

T3C

T3C

T3A (EF)

—

230/110

300 W PS30

T3C

T3C

T3A (EF)

—

230/110

NOTE: Ambient suitability of these incandescent fixtures: 104°F/40 °C
† For Group A, use Pendant Mount only.

1276

Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

A-51® Incandescent Factory Sealed Luminaires
For Group C and D Locations. Explosionproof

Suitable for use in Wet Locations. UNILETS for use with Threaded Metal Conduit.
Class I, Division 1 and 2, Groups C, D
Class II, Division 1 and 2, Groups E, F, G
Class III

Hub Size
(Inches)

Catalog
Number ➋

60-100 W (AAU-1N)
A-21

1/2

AP1050

3/4

AP1075

1

AP10100

150-300 W (AAU-15N)
A-23 PS-25

1/2

AP1550

3/4

AP1575

Type
Pendant — One Hub, Rigid or Flexible Mounting

1

AP15100

1/2

AP2050

3/4

AP2075

1

AP20100

1/2

AC1050

3/4

AC1075

1

AC10100

1/2

AC1550

3/4

AC1575

1

AC15100

1/2

AC2050

3/4

AC2075

1

AC20100

60-100 W (AAU-1N)
A-21

1-1/2 ➋

AN10150

150-300 W (AAU-15N)
A-23 PS-25

1-1/2 ➋

AN15150

200-300 W (AAU-2NS)
PS-30

1-1/2 ➋

AN20150

200-300 W (AAU-2NS)
PS-30

Ceiling — Four Hubs, Three Close-up Plugs

150-300 W (AAU-15N)
A-23 PS-25

200-300 W (AAU-2NS)
PS-30

Lighting: Explosionproof — Area — Incandescent

60-100 W (AAU-1N)
A-21

25° Stanchion — One Hub — Not UL Listed

Lighting

➊ See A-51® Incandescent Factory Sealed Luminaire Classified Area Suitability page for suitability of specific fixtures.
➋ 1-1/2” tapped hub furnished with a 1-1/2” to 1-1/4” reducer.
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

1277

A-51® Incandescent Factory Sealed Luminaires
For Group C and D Locations. Explosionproof

Suitable for use in Wet Locations. UNILETS for use with Threaded Metal Conduit.
Class I, Division 1 and 2, Groups C, D
Class II, Division 1 and 2, Groups E, F, G
Class III

Hub Size
(Inches)

Type

Catalog
Number ➋

Long Bracket — Four Hubs, Three Close-up Plugs
60-100 W (AAU-1N)
A-21

1/2

ALB1050

3/4

ALB1075

1

ALB10100

150-300 W (AAU-15N)
A-23 PS-25

1/2

ALB1550

3/4

ALB1575

1

ALB15100

1/2

ALB2050

3/4

ALB2075

1

ALB20100

60-100 W (AAU-1N)
A-21

1/2

ASB1050

3/4

ASB1075

150-300 W (AAU-15N)
A-23 PS-25

1/2

ASB1550

3/4

ASB1575

200-300 W (AAU-2NS)
PS-30

1/2

ASB2050

3/4

ASB2075

200-300 W (AAU-2NS)
PS-30

Lighting

Lighting: Explosionproof — Area — Incandescent

15° Short Bracket — Two Hubs, One Close-up Plug

Three-Way Exit Sign

Epoxy enameled steel – 6”/152.4 mm-high red lettering 60-200 W 	
(Mounts to AAU-1N or AAU-15N fixture units in place of guard)

CJEXRN

Epoxy enameled steel – 6”/152.4 mm-high red lettering 60-200 W 	
(Mounts to AAU-1N or AAU-15N fixture units in place of guard)
(See page G2-24 for dimensions)

AEXR-15R

Single-Sided Exit Sign

Guard — Add suffix to fixture catalog number
-G

Guard

➊ See A-51® Incandescent Factory Sealed Luminaire Classified Area Suitability page for suitability of specific fixtures.

1278

Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

A-51® Incandescent Factory Sealed Luminaire Accessories
For Group C and D Locations. Explosionproof

Suitable for use in Wet Locations. UNILETS for use with Threaded Metal Conduit.
Class I, Division 1 and 2, Groups C, D
Class II, Division 1 and 2, Groups E, F, G
Class III

Mounting Hoods
Type

Hub Size (Inches)

Catalog Number

Pendant — One Hub, Rigid or Flexible Mounting
1/2

AAP-50

3/4

AAP-75

1

AAP-100

1/2

AAC-50

3/4

AAC-75

1

AAC-100

Ceiling — Four Hubs, Three Close-up Plugs

25° Stanchion — Not UL Listed — One Hub
1-1/2

AAN-150 ➊

Long Bracket — Four Hubs, Three Close-up Plugs
AALB-50

3/4

AALB-75

1

AALB-100

1/2

AASB-50

3/4

AASB-75

15˚ Short Bracket — Two Hubs, One Close-up Plug

Type

Catalog Number

Fixture Units
60-100 W A-21

AAU-1N

150-300 W A-23 & PS-25

AAU-15N

200-300 W PS-30

AAU-2NS

60-100 W (AAU-1N)

AAGL-1PR

150-300 W (AAU-15N)

AAGL-1PR

200-300 W (AAU-2NS)

AAGL-2PR

60-100 W (AAU-1N)

AAGU-1

150-300 W (AAU-15N)

AAGU-1

200-300 W (AAU-2NS)

AAGU-2

300-500 W (AAU-5NS)

AAGU-5

Lighting: Explosionproof — Area — Incandescent

1/2

Prismatic Glass Globes

➊ 1-1/2” tapped hub furnished with a 1-1/2” to 1-1/4” reducer.
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

1279

Lighting

Aluminum Guards

A-51® Incandescent Factory Sealed Luminaire Accessories
For Group C and D Locations. Explosionproof

Suitable for use in Wet Locations. UNILETS for use with Threaded Metal Conduit.

Type
Standard Dome

Fixture Size

Catalog Number

(Not for use with short brackets)

Porcelain

Polyester

60-100 W (AAU-1N)
150-300 W (AAU-15N)
200-300 W (AAU-2NS)
300-500 W (AAU-5NS)

Porcelain
AARW-15ST
AARW-15ST
AARW-2ST
AARW-5ST

Polyester
—
—
AARP-2ST
—

60-100 W (AAU-1N)
150-300 W (AAU-15N)
200-300 W (AAU-2NS)

AARW-15AN
AARW-15AN
AARW-2AN

—
—
AARP-2AN

30˚ Angle

Porcelain

Polyester

Colored Glass Globes

Lighting: Explosionproof — Area — Incandescent

Amber
AAGL-1A
AAGL-1A
AAGL-2A

60-100 W (AAU-1N)
150-300 W (AAU-15N)
200-300 W (AAU-2NS)
Green

AAGL-1G
AAGL-1G
AAGL-2G

60-100 W (AAU-1N)
150-300 W (AAU-15N)
200-300 W (AAU-2NS)
Red
60-100 W (AAU-1N)
150-300 W (AAU-15N)
200-300 W (AAU-2NS)

AAGL-1R
AAGL-1R
AAGL-2R

60-100 W (AAU-1N) — Medium Base
150-300 W (AAU-15N) — Medium Base
200-300 W (AAU-2NS) — Medium Base
300-500 W (AAU-5NS) — Mogul Base

AASP-11
AASP-22
AASP-22
AASP-44

Replacement Socket

Connection Block
Fits A-51 Mounting Hoods
VPT-7

Lighting

60-500 W
Globe Gaskets — Fiber and Aluminum
Requires one of each
60-300 W (AAU-1N and AAU-15N)
200-300 W (AAU-2NS)
300-500 W (AAU-NS)

1280

Fiber
AASP-15V
AASP-2V
AASP-5V

Aluminum
AASP-15A
AASP-2A
AASP-5A

Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

A-51® Incandescent Factory Sealed Luminaire Dimensions
For Group C and D Locations. Explosionproof

Suitable for use in Wet Locations. UNILETS for use with Threaded Metal Conduit.

3.38"/
85.9 mm

5.38"/
116.7 mm
4.69"/
119.1 mm

Stanchion

.38"/
2.69"/
9.7 mm 68.3
mm

2.63"/
66.8 mm

.38"/
9.7 mm

5.75"/
146.1 mm

Size (Watts)

4.75"/
120.7 mm

1.31"/
33.3 mm

Pendant ➊

Ceiling

Long Bracket

Short Bracket

C
A
B
C
A
B
C
7.06/ 13.75/ 13.13/ 12.38/ 13.56/ 12.94/ 9.13/
179.3 349.3 333.5 314.5 344.4 328.7 231.9

150-300

11.47/ 10.85/ 11.50/ 12.25/ 11.63/ 7.06/ 13.75/ 13.13/
291.3 275.6 292.1 311.2 295.4 179.3 349.3 333.5

7.06/ 13.75/ 13.13/ 12.38/ 13.56/ 12.94/ 9.13/
179.3 349.3 333.5 314.5 344.4 328.7 231.9

200-300

13.07/ 12.38/ 12.71/ 13.94/ 13.25/ 8.81/ 15.44/ 14.75/
332.0 314.5 322.8 354.1 336.6 223.8 392.2 374.7

8.81/ 15.50/ 14.75/ 13.25/ 15.19/ 14.50/ 10.13/
223.8 392.2 374.7 336.6 385.8 363.8 257.3

300-500

15.09/ 14.34/ 14.64/ 16.00/ 15.25/ 12.13/ 17.50/ 17.75/ 12.13/ 17.50/ 16.75/ 14.88/ 17.25/ 16.50/ 11.94/
383.3 364.2 371.8 406.4 387.4 308.1 444.5 450.9 308.1 444.5 425.9 378.0 438.2 419.1 303.3

60-100

A➋

B➋

A

B

A

60-100

Size (Watts)

12.00/304.8

4.50/114.3

10.00/254.0

7.63/193.8

-

B

150-200

14.00/355.6

4.38/111.3

10.00/254.0

7.63/193.8

-

-

200-300

16.00/406.4

5.19/131.8

12.00/304.8

7.88/200.2

12.00/304.8

6.06/153.9

300-500

20.00/508.0

6.84/173.7

18.00/457.2

13.13/333.5

18.00/457.2

9.13/231.9

-

Lighting: Explosionproof — Area — Incandescent

A
B
C
A
B
C
A
B
11.47/ 10.85/ 11.50/ 12.25/ 11.63/ 7.06/ 13.75/ 13.13/
291.3 275.6 292.1 311.2 295.4 179.3 349.3 333.5

Lighting

➊ For dimensions of fixture unit only, subtract pendant hood dimension 1.31”/3.3 cm from dimensions A and B as listed.
➋ Dimensions illustrated are for porcelain steel (dome and angle) and etched aluminum (high bay).
Overall dimensions for fiberglass reinforced polyester reflectors are: standard dome – 16-1/2”/419.1 mm dia., 6” high; 30° Angle – 14-3/8”/374.7 mm dia.,
10”/254 mm high.
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

1281

A-51® Incandescent Factory Sealed Luminaire Photometric Data
For Group C and D Locations. Explosionproof

Suitable for use in Wet Locations. UNILETS for use with Threaded Metal Conduit.
	

Photometric data shown here is based on a 200-	
watt type PS-30 lamp and is representative of 	
the performance for all A-51 incandescent fixtures 	
using 60-watt to 500-watt lamps. For candlepower
values of fixtures with other lamps, use the following
multipliers: 	

60 W A-19 – 0.23; 	
150 W A-21 – 0.75; 	
200 W A-25 – 1.02; 	
300 W PS-25 – 1.70; 	
300 W PS-35 – 1.55; 	
500 W PS-40 – 2.69.

A-51 Incandescent
Fixture without Reflector
Spacing to Mtg. Ht. 	
Ratio 1.25:1	
Guard .877

100 W A-19 – 0.47; 	
200 W A-23 – 1.07; 	
200 W PS-25 – 1.03: 	
300 W PS-30 – 1.63; 	
500 W PS-35 – 2.95; 	

	

To determine candlepower values of fixtures with a
guard, multiply by value shown with each curve.

Effective Floor Cavity Reflectance (Rfc) is 20%
% Ceiling Rcc
% Walls Rw

80
50

30

70
10

50

30

50
10

50

30

30
10

50

30

10
10

50

30

0
10

0

1 .735 .690 .651 .695 .655 .618 .622 .590 .561 .554 .530 .506 .493 .473 .454 .422

ROOM CAVITY RATIOS

2 .621 .558 .503 .588 .530 .481 .525 .478 .437 .467 .430 .396 .413 .384 .357 .327
3 .540 .468 .411 .512 .446 .394 .457 .404 .359 .406 .363 .327 .360 .325 .294 .267
4 .474 .400 .342 .450 .381 .328 .402 .346 .301 .359 .312 .274 .318 .280 .248 .223
5 .415 .341 .284 .394 .325 .272 .354 .295 .251 .316 .266 .229 .280 .240 .207 .184
6 .372 .297 .245 .352 .284 .233 .316 .258 .215 .283 .234 .197 .252 .210 .178 .157
7 .334 .262 .213 .317 .249 .203 .285 .227 .187 .255 .207 .170 .228 .187 .155 .136
8 .300 .231 .182 .285 .221 .175 .256 .202 .162 .231 .183 .148 .206 .165 .135 .117
9 .271 .204 .157 .258 .195 .152 .233 .178 .140 .209 .162 .128 .187 .146 .117 .100
10 .246 .181 .139 .234 .175 .135 .212 .160 .124 .191 .145 .113 .172 .132 .102 .087

Lighting: Explosionproof — Area — Incandescent

A-51 Incandescent Fixture with
Standard Dome Reflector
Spacing to Mtg. Ht. 	
Ratio 1.25:1	
Guard .890

Effective Floor Cavity Reflectance (Rfc) is 20%
% Ceiling Rcc
% Walls Rw

80
50

30

70
10

50

30

50
10

50

30

30
10

50

30

10
10

50

30

0
10

0

1 .757 .727 .700 .740 .713 .689 .709 .686 .667 .681 .663 .646 .656 .641 .627 .612

ROOM CAVITY RATIOS

2 .660 .613 .572 .647 .603 .567 .621 .585 .552 .598 .568 .540 .577 .551 .528 .512
3 .580 .524 .478 .570 .516 .475 .549 .504 .466 .529 .490 .458 .511 .478 .449 .434
4 .514 .452 .403 .504 .446 .400 .486 .436 .395 .469 .425 .390 .454 .415 .384 .368
5 .451 .385 .336 .442 .380 .334 .427 .372 .332 .413 .364 .327 .399 .357 .323 .308
6 .402 .336 .291 .394 .333 .286 .381 .326 .285 .369 .319 .282 .358 .313 .279 .264
7 .361 .296 .254 .355 .293 .250 .343 .286 .247 .332 .282 .245 .323 .278 .243 .229
8 .323 .261 .216 .318 .258 .216 .308 .254 .215 .299 .249 .213 .290 .245 .211 .197
9 .291 .230 .187 .287 .227 .187 .278 .223 .186 .269 .219 .184 .262 .216 .182 .169

Lighting

10 .264 .204 .166 .259 .204 .166 .253 .200 .164 .245 .197 .162 .240 .194 .161 .149

1282

Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

A-51® Incandescent Factory Sealed Luminaire Photometric Data
For Group C and D Locations. Explosionproof

Suitable for use in Wet Locations. UNILETS for use with Threaded Metal Conduit.
Photometric data shown here is based on a 200watt type PS-30 lamp and is representative of the
performance for all A-51 incandescent fixtures
using 60-watt to 500-watt lamps. For candlepower
values of fixtures with other lamps, use the following
multipliers: 	

60 W A-19 – 0.23; 	
150 W A-21 – 0.75; 	
200 W A-25 – 1.02; 	
300 W PS-25 – 1.70; 	
300 W PS-35 – 1.55; 	
500 W PS-40 – 2.69.

100 W A-19 – 0.47; 	
200 W A-23 – 1.07; 	
200 W PS-25 – 1.03: 	
300 W PS-30 – 1.63; 	
500 W PS-35 – 2.95; 	

To determine candlepower values of fixtures with a
guard, multiply by value shown with each curve.

Effective Floor Cavity Reflectance (Rfc) is 20%
% Ceiling Rcc
A-51 Incandescent Fixture
with High Bay Reflector

% Walls Rw

80
50

30

70
10

50

30

50
10

50

30

30
10

50

30

10
10

50

30

0
10

0

1 .686 .644 .645 .671 .651 .634 .644 .628 .614 .620 .607 .595 .598 .588 .577 .566

Spacing to Mtg.
Ht. Ratio 1.40:1	
Guard .865

12.00"/
304.8 mm

ROOM CAVITY RATIOS

2 .614 .580 .549 .603 .571 .545 .581 .555 .531 .562 .540 .520 .544 .525 .508 .496
3 .550 .508 .473 .542 .501 .470 .524 .490 .461 .507 .478 .454 .492 .467 .446 .434
4 .493 .445 .408 .486 .441 .404 .470 .431 .400 .456 .422 .395 .443 .413 .389 .377
5 .439 .387 .349 .432 .383 .347 .420 .376 .344 .407 .369 .340 .396 .383 .336 .324
6 .393 .340 .304 .387 .338 .300 .376 .331 .298 .366 .326 .296 .356 .320 .293 .281
7 .352 .299 .264 .347 .296 .261 .337 .290 .258 .327 .287 .256 .320 .283 .254 .242
8 .313 .261 .224 .309 .259 .223 .300 .255 .222 .293 .251 .220 .285 .247 .219 .207
9 .280 .228 .191 .276 .225 .191 .268 .222 .190 .261 .219 .189 .254 .216 .187 .176
10 .252 .201 .168 .248 .201 .168 .242 .197 .167 .236 .195 .165 .231 .192 .164 .153

Lighting: Explosionproof — Area — Incandescent

A-51 Incandescent Fixture
with 30°˚ Reflector

11.16"/
283.5 mm
B—
Back
S—Side
F—Front
G—Front W.Guard

Lighting

Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

1283

A-51® Incandescent Factory Sealed Luminaires
For Group A and B Locations. Explosionproof

Suitable for use in Wet Locations. UNILETS for use with Threaded Metal Conduit.
Class I, Division 1 and 2, Groups A, B, C, D
Class II, Division 1 and 2, Groups E, F, G
Class III

Hub Size
(Inches)

Catalog
Number ➊➋

Pendant  — One Hub, Rigid or Flexible Mounting
60-200 W (AAUA-15)

1/2

AAPA1550

PS-25

3/4

AAPA1575

200-300 W (AAUA-2)

1/2

AAPA2050

PS-30

3/4

AAPA2075

60-200 W (AAUA-15)

1/2

AACA1550

PS-25

3/4

AACA1575

200-300 W (AAUA-2)

1/2

AACA2050

PS-30

3/4

AACA2075

60-200 W (AAUA-15)

1/2

AASBA1550

PS-25

3/4

AASBA1575

200-300 W (AAUA-2)

1/2

AASBA2050

PS-30

3/4

AASBA2075

Porcelain

Polyester

Lighting: Explosionproof — Area — Incandescent

Ceiling — Four Hubs, Three Close-up Plugs

15˚ Short Bracket — Two Hubs, One Close-up Plug

Reflectors
Porcelain

Polyester
Standard Dome
60-200 W (AAUA-15)

AARW-15ST

200-300 W (AAUA-2)

AARW-2ST

60-200 W (AAUA-15)

AARW-15AN

200-300 W (AAUA-2)

AARW-2AN

AARP-2ST

30˚ Angle

Lighting

AARP-2AN

➊ See A-51® Incandescent Factory Sealed Luminaire Classified Area Suitability page for suitability of specific fixtures.

➋ Add suffix -G to catalog number for optional guard.
 Shaded area indicates pendant mount is suitable for Class I, Group A in addition to other applicable area suitabilities.

1284

Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

A-51® Incandescent Factory Sealed Luminaires
For Group A and B Locations. Explosionproof

Suitable for use in Wet Locations. UNILETS for use with Threaded Metal Conduit.
Class I, Division 1 and 2, Groups A, B, C, D
Class II, Division 1 and 2, Groups E, F, G
Class III

Mounting Hoods
Type

Hub Size (Inches)

Catalog Number

One Hub, 	
Rigid or Flexible Mounting

1/2

AAP-50 ➊

3/4

AAP-75 ➊

Four Hubs,
Three Close-up Plugs

1/2

AAC-50

3/4

AAC-75

Two Hubs,
One Close-up Plug

1/2

AASB-50

3/4

AASB-75

Pendant

Ceiling

15˚ Short Bracket

Description

Catalog Number

60-200 W
PS-25

AAUA-15

200-300 W
PS-30

AAUA-2

60-200 W (AAUA-15)

AAGLA-15

200-300 W (AAUA-2)

AAGLA-2

60-200 W (AAUA-15)

AAGUA-15

200-300 W (AAUA-2)

AAGU-2

60-200 W (AAUA-15)

AASPA-15

200-300 W (AAUA-2)

AASPA-22

Globe and Ring Assembly

Aluminum Guards

Lighting: Explosionproof — Area — Incandescent

Fixture Units

Medium Base Lamp Socket

Fits all A-51 and AA-51 mounting hoods
60-300 W

VPT-7

➊ Group A pendant mount only.
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

1285

Lighting

Connection Block

A-51® Incandescent Factory Sealed Luminaire Dimensions
For Group A and B Locations. Explosionproof

Suitable for use in Wet Locations. UNILETS for use with Threaded Metal Conduit.

Dimensions in In/mm

4.75"/
120.7 mm

3.38"/
85.9 mm
5.38"/
116.7 mm

.38"/
9.7 mm
2.63"/
66.8 mm

4.69"/
119.1 mm

.38"/
9.7 mm

Size
(Watts)

Pendant
A

B

Ceiling
C

A

B

Short Bracket
C

A

B

C

60-200

13.69/347.7 13.13/333.5

7.06/179.3 16.50/419.1 15.94/404.9

7.06/179.3 15.00/381.0 14.44/366.8

9.50/241.3

200-300

14.75/374.7 13.69/347.7

8.81/223.8 17.56/446.0 16.50/419.1

8.81/223.8 16.00/406.4 15.44/392.2 10.38/263.7

Lighting

Lighting: Explosionproof — Area — Incandescent

1.31"/
33.3 mm

1286

Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

A-51® Incandescent Factory Sealed Luminaire Photometric Data
For Group A and B Locations. Explosionproof

Suitable for use in Wet Locations. UNILETS for use with Threaded Metal Conduit.
Photometric data shown here is based on a 200-watt
type PS-25 lamp, and is representative of the performance for A-51 incandescent fixtures (Groups A and
B). For candlepower values of fixtures with other lamps,
use the following multipliers: 150 W (PS-25) – 0.70; and
300 W (PS-25) – 1.6. To determine candlepower values

of fixtures with a guard, multiply by value shown with
each curve.

Effective Floor Cavity Reflectance (Rfc) is 20% (No Reflector)
% Ceiling Rcc
% Walls Rw

80
50

30

70
10

50

30

50
10

50

30

30
10

50

30

10
10

50

30

0
10

0

1 .711 .669 .630 .669 .631 .595 .590 .560 .533 .518 .495 .473 .452 .434 .417 .383
ROOM CAVITY RATIOS

2 .602 .541 .488 .567 .511 .465 .499 .455 .416 .437 .402 .371 .380 .352 .327 .296

7.13"/
181.1 mm

3 .519 .449 .393 .488 .424 .374 .430 .379 .336 .375 .335 .300 .325 .292 .264 .236
4 .456 .384 .328 .430 .364 .312 .379 .325 .282 .332 .288 .252 .288 .252 .223 .197
5 .400 .328 .274 .378 .311 .260 .334 .278 .236 .293 .247 .211 .254 .217 .187 .164
6 .357 .285 .234 .336 .270 .221 .297 .242 .200 .261 .215 .180 .227 .188 .159 .138
7 .318 .248 .200 .300 .234 .190 .265 .209 .171 .233 .187 .153 .204 .165 .135 .116
8 .287 .219 .172 .270 .208 .164 .240 .187 .149 .212 .167 .134 .104 .147 .119 .101
9 .260 .194 .150 .246 .185 .143 .218 .166 .130 .192 .148 .117 .168 .131 .103 .087
10 .236 .173 .132 .222 .166 .126 .199 .149 .114 .175 .133 .102 .154 .117 .090 .075

Effective Floor Cavity Reflectance (Rfc) is 20% (No Reflector)
% Ceiling Rcc
50

30

70
10

50

30

50
10

50

30

30
10

50

30

10
10

50

30

0
10

0

1 .797 .763 .733 .779 .748 .721 .745 .720 .697 .715 .695 .676 .689 .671 .655 .640

14.00"/
355.6 mm

ROOM CAVITY RATIOS

2 .687 .633 .586 .673 .622 .581 .645 .603 .566 .620 .585 .553 .597 .567 .541 .524
3 .594 .530 .478 .583 .522 .474 .560 .508 .464 .538 .494 .457 .519 .481 .448 .431
4 .527 .458 .404 .517 .452 .400 .497 .440 .395 .479 .430 .390 .462 .419 .384 .366
5 .466 .393 .340 .456 .388 .337 .440 .379 .335 .424 .371 .330 .410 .364 .326 .310
6 .414 .342 .292 .406 .339 .288 .391 .331 .286 .378 .324 .283 .367 .317 .280 .264
7 .369 .298 .252 .362 .294 .248 .350 .288 .245 .337 .284 .242 .328 .279 .240 .225
8 .333 .265 .217 .327 .262 .216 .316 .257 .215 .307 .252 .213 .297 .248 .211 .196
9 .302 .235 .189 .297 .232 .189 .287 .229 .188 .278 .224 .186 .270 .221 .185 .170
10 .273 .209 .167 .268 .209 .167 .261 .204 .166 .253 .201 .163 .247 .198 .162 .149

Lighting: Explosionproof — Area — Incandescent

% Walls Rw

80

Lighting

11.16"/
283.5 mm

Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

1287

EDT Incandescent Luminaires
Dust-Ignitionproof

Suitable for use in Wet Locations.
Class II, Division 1 and 2, Groups E, F, G
Class III

Description

Watts

Hub Size
(Inches)

60-200 W

1/2

Catalog
Number

Pendant Lighting Fixture ➊

9.00"/
228.6 mm

One tapped opening for rigid or flexible mounting,
with heat-resistant clear globe

EDTP2050

5.25"/
133.4 mm

Heat-Resistant Clear Glass Globe
4.28"/
108.7 mm
7.00"/
177.8 mm

60-200 W

VSGL-2HR

60-200 W

DPGU-2

60-200 W

VPLR-123

5.25"/
133.4 mm

4.28"/
108.7 mm
7.00"/
177.8 mm
5.25"/
133.4 mm

Replacement Porcelain Shock-Absorbing Socket — Medium Base

Lighting

Lighting: Explosionproof — Area — Incandescent

Globe Guard

➊ T3C maximum operating temperature. Supply wire 302 °F/150 °C. Maximum ambient temperature 77 °F/25 °C. Vertical mount only (globe down).

1288

Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

Code•Master 2™ HID Factory Sealed Floodlights
Marine (Outside Type). Explosionproof

Integrally Ballasted. 150 W, 250 W, 400 W HPS; 150 W, 175 W, 250 W, 320 W, 350 W, 400 W PSMH; 175 W, 250 W, 400 W MH V. Mogul Base.
NEC:
Class 1, Division 1 and 2, Groups C, D
Marine Type Electric Fixtures
Outside Type (Salt Water)

CEC: V
Class I, Division 1 and 2, Groups B, C, D
Class II, Division 1, Groups E, F, G
Class II, Division 2, Groups F, G
Class III
CSA 4X

Applications
•	 UL Listed for Marine Type Electric Fixtures Outside Type (Salt
Water).
•	 Ideal in Class I, Division 1 and 2 installations in refineries, in
pipeline transportation facilities, at drilling rigs and in production
facilities on land and marine platforms.
•	 Class I, Division 1 areas include:
(1) enclosed derricks, mud tanks, desander-desilter, gasoperated control devices, oil-gas separation vessels, shale
shakers and flowing or beam wells
(2) flowing or beam wells in open areas with cellar or below
grade sump
(3) on refinery docks where tankers are loaded with hoses or
loading arms
(4) in compressor buildings (open or enclosed) where methane
gas is present
•	 Virtually all enclosed areas at drilling operations or refineries
where ventilation is inadequate, or where a cellar or below grade
sump exists, are Class I, Division 1.

Shown with Optional High Bay Reflector

Features

Effective Protected area: 1.8 Square Feet

Options
•	 Fuses for field installation are ordered by catalog number from
the fuse kit table
•	 Quartz Auxiliary Emergency Lamp for PSMH and HPS fixtures.
Relay switch installed fixture. Add suffix -E to fixture catalog
number.
•	 “Smart Hot Restrike” Emergency Option available for 150 W
HPS.  Add suffix -SR.  
•	 Hot Restrike Option available for 150 W HPS. Add suffix -R.
•	 Smart Starter. Add suffix -S

Certifications and Compliances
•	
•	
•	
•	

UL Standard: UL 1598, UL 844
UL Listed: E10444
CSA Standard: C22.2 No. 250, C22.2 No. 137
CSA Certified: 025428

Lighting: Explosionproof — Floodlight

•	 Choice of mountings: (1) crossarm with degree indicator; (2)
junction box for horizontal or vertical mount; and (3) swivel for
pole mount (screws onto standard 2” pipe threads).
•	 Fixtures operate safely in high ambient temperatures. For
example, in Class I areas the 150 W HPS unit operates at a
maximum fixture surface temperature of 248 °F/120 °C in a
149 °F/65 °C ambient (212 °F/100 °C temperature in a 104 °F/
40 °C ambient).
•	 Arrangement of heat-producing components results in more
efficient heat dissipation for cooler fixture operation.
•	 All threaded joints are flame-tight.
•	 Five threads are always fully engaged in an 	
explosionproof manner.
•	 Factory sealed. External seals not required.
•	 Strategic location of lamp socket, in combination with the
interior prism design of the glass globe, provides optimum light
distribution and control.
•	 Heat- and impact-resistant globes have smooth 	
dust-resistant exterior.
•	 Superior corrosion resistance, with epoxy powder coat finish.
•	 Ballasts operate at low temperatures – PSMH: -20 °F/-29 °C;
HPS: -40 °F/ -40 °C.

Standard Materials
•	 Ballast housing, guard and junction box, and pole mounts:
copperfree (4/10 of 1% max.) aluminum
•	 Crossarm mount: malleable iron
•	 Trunnion: steel.
•	 High bay reflector: aluminum
•	 Standard dome, deep dome and 30° angle reflectors: 	
fiberglass reinforced polyester
•	 Socket: porcelain
•	 Screw shell: nickel-plated phosphor bronze

Standard Finishes
•	 Ballast housing, guard, trunnion and mounting accessories:
epoxy-clad finish. Powder coat baked finish, electrostatically
applied for complete, uniform corrosion protection

Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

Lighting

V CSA Certification only.

1289

Code•Master 2™ HID Factory Sealed Floodlights
Marine (Outside Type). Explosionproof

Integrally Ballasted. 150 W, 250 W, 400 W HPS; 150 W, 175 W, 250 W, 320 W, 350 W, 400 W PSMH; 175 W, 250 W, 400 W MH V. Mogul Base.
NEC:
Class 1, Division 1 and 2, Groups C, D
Marine Type Electric Fixtures
Outside Type (Salt Water)

CEC: V
Class I, Division 1 and 2, Groups B, C, D
Class II, Division 1, Groups E, F, G
Class II, Division 2, Groups F, G
Class III
CSA 4X

Classified Area Suitability — Suitability includes use of reflector

Lamp
Type

High Pressure
Sodium

Pulse Start
Metal Halide

Supply Wire
(°F/˚°C)

Ambient Temp
(°F/°˚C)

150

122/60

104/40

T5

C,D

Class II, Division 1 & 2
With Globe or with Globe & Reflector
CEC Temp. Ident. No.
Nameplate
CEC V
Marking
Groups

B, C, D

T3A

E,F

150

167/75

131/55

—

C,D

B, C, D

T3

—

250

167/75

104/40

T4

C,D

B, C, D

—

—

250

167/75

131/55

—

C,D

B, C, D

—

—

400

185/85

104/40

T3A

C,D

B, C, D

—

—

175

167/75

104/40

T3B

C,D

B, C, D

T3C

E,F,G

250

167/75

104/40

T3B

C,D

B, C, D

T3A

E,F

320

167/75

104/40

T3

C,D

B, C, D

—

—

350

167/75

104/40

T3

C,D

B, C, D

—

—

400

167/75

104/40

T3

C,D

B, C, D

—

—

175

167/75

104/40

T4

—

B, C, D

T3C

E, F, G

250

167/75

104/40

T4

—

B, C, D

T3A

E, F

400

167/75

104/40

T3C

—

B, C, D

—

—

Lighting

Lighting: Explosionproof — Floodlight

Metal Halide V

Lamp
Watts

Class I, Division 1 & 2 With Globe or with
Globe & Reflector UL/NEC/CEC Temp. Ident. No.
Nameplate
NEC
CEC V
Marking
Groups
Groups

V CSA Certification only.

1290

Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

Code•Master 2™ HID Factory Sealed Floodlights
Marine (Outside Type). Explosionproof

Integrally Ballasted. 150 W, 250 W, 400 W HPS; 150 W, 175 W, 250 W, 320 W, 350 W, 400 W PSMH. Mogul Base.
NEC:
Class 1, Division 1 and 2, Groups C, D
Marine Type Electric Fixtures
Outside Type (Salt Water)

Lamp
Watts

ANSI Lamp Type
HPS

PSMH

HPS

Catalog Number ➊➌
PSMH

Fixture Unit
Furnished with Trunnion 3/4” hub. (3/4 – 14 NPT)
150
175
250
320
350
400

S55
—
S50
—
—
S51

M102
M137/M152
M138/M153
M145
M131
M135/M155

CFL150MT
—
CFL250MT
—
—
CFL400MT

CFP150MT
CFP175MT
CFP250MT
CFP320MT
CFP350MT
CFP400MT

Fixture Unit with Junction Box for Horizontal or Vertical Mounting ➋
3/4” fixture hub and two conduit openings (3/4 – 14 NPT). 30” Flexible Coupling connects to 3/4” fixture hub
and to 1/2” junction box opening. Furnished with one 3/4” Close-up Plug. Has Locking Screw for horizontal
adjustment.
150
175
250
320
350
400

S55
—
S50
—
—
S51

M102
M137/M152
M138/M153
M145
M131
M135/M155

CFL150JBMT
—
CFL250JBMT
—
—
CFL400JBMT

CFP150JBMT
CFP175JBMT
CFP250JBMT
CFP320JBMT
CFP350JBMT
CFP400JBMT

Fixture Unit with Pole-Top Mount (on 2” Threaded Pipe) ➋
2” tapered threads (2 – 11-1/2 NPT). Locking Screw for horizontal adjustment. 30” Flexible Coupling connects
to 3/4” fixture hub (3/4 – 14 NPT) and to 1/2” pole-top opening (1/2-14 NPT).
150

S55

M102

CFL150SFMT

CFP150SFMT

175

—

M137/M152

—

CFP175SFMT

250

S50

M138/M153

CFL250SFMT

CFP250SFMT

320

—

M145

—

CFP320SFMT

350

—

M131

—

CFP350SFMT

400

S51

M135/M155

CFL400SFMT

CFP400SFMT

For mounting to flat surface. 180° horizontal adjustment with degree indicator.  30” Flexible Coupling connects
to 3/4” fixture hub (3/4 – 14 NPT) and to any 1/2” opening (1/2 – 14 NPT).
150
175
250
320
350
400

S55
—
S50
—
—
S51

M102
M137/M152
M138/M153
M145
M131
M135/M155

CFL150CAMT
—
CFL250CAMT
—
—
CFL400CAMT

CFP150CAMT
CFP175CAMT
CFP250CAMT
CFP320CAMT
CFP350CAMT
CFP400CAMT

Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

1291

Lighting

➊ To order fixture with guard, add suffix -G before voltage suffix.
➋ Fixtures furnished with trunnion and bolts, flexible coupling and fittings, and mounting accessory. The trunnion provides vertical adjustment and the mounting
accessory provides horizontal adjustment.
➌ Change suffix -MT (120/208/240/277 V) to -480 for 480 V.

Lighting: Explosionproof — Floodlight

Fixture Unit with Crossarm Mounting ➋

Code•Master 2™ HID Factory Sealed Floodlights V
Marine (Outside Type). Explosionproof

Integrally Ballasted. 150 W, 250 W, 400 W HPS; 150 W, 175 W, 250 W, 320 W, 350 W, 400 W PSMH; 175 W, 250 W, 400 W MH. Mogul Base.
CEC: V
Class I, Division 1 and 2, Groups B, C, D
Class II, Division 1, Groups E, F, G
Class II, Division 2, Groups F, G
Class III
CSA 4X

Lamp
Watts

HPS

ANSI Lamp Type
PSMH

MH

HPS

Catalog Number ➊➌
PSMH

MH

Fixture Unit
Furnished with Trunnion 3/4” hub. (3/4 – 14 NPT)
150
175
250
320
350
400

S55
—
S50
—
—
S51

M102
M137/M152
M138/M153
M145
M131
M135/M155

—
M57/H39
M58/H37
—
—
M59/H33

CFL150TTCN
—
CFL250TTCN
—
—
CFL400TTCN

CFP150TTCN
CFP175TTCN
CFP250TTCN
CFP320TTCN
CFP350TTCN
CFP400TTCN

—
CFH175TTCN
CFH250TTCN
—
—
CFH400TTCN

Fixture Unit with Junction Box for Horizontal or Vertical Mounting ➋
3/4” fixture hub and two conduit openings (3/4 – 14 NPT). 30” Flexible Coupling connects to 3/4” fixture hub
and to 1/2” junction box opening. Furnished with one 3/4” Close-up Plug. Has Locking Screw for horizontal
adjustment.
150
175
250
320
350
400

S55
—
S50
—
—
S51

M102
M137/M152
M138/M153
M145
M131
M135/M155

—
M57/H39
M58/H37
—
—
M59/H33

CFL150JBTTCN
—
CFL250JBTTCN
—
—
CFL400JBTTCN

CFP150JBTTCN
CFP175JBTTCN
CFP250JBTTCN
CFP320JBTTCN
CFP350JBTTCN
CFP400JBTTCN

—
CFH175JBTTCN
CFH250JBTTCN
—
—
CFH400JBTTCN

Fixture Unit with Pole-Top Mount (on 2” Threaded Pipe) ➋

Lighting

Lighting: Explosionproof — Floodlight

2” tapered threads (2 – 11-1/2 NPT). Locking Screw for horizontal adjustment. 30” Flexible Coupling connects
to 3/4” fixture hub (3/4 – 14 NPT) and to 1/2” pole-top opening (1/2-14 NPT).
CFL150SFTTCN

CFP150SFTTCN

150

S55

M102

—

175

—

M137/M152

M57/H39

250

S50

M138/M153

M58/H37

320

—

M145

—

—

CFP320SFTTCN

—

350

—

M131

—

—

CFP350SFTTCN

—

400

S51

M135/M155

M59/H33

—
CFL250SFTTCN

CFL400SFTTCN

—

CFP175SFTTCN

CFH175SFTTCN

CFP250SFTTCN

CFH250SFTTCN

CFP400SFTTCN

CFH400SFTTCN

Fixture Unit with Crossarm Mounting ➋
For mounting to flat surface. 180° horizontal adjustment with degree indicator.  30” Flexible Coupling connects
to 3/4” fixture hub (3/4 – 14 NPT) and to any 1/2” opening (1/2 – 14 NPT).
150
175
250
320
350
400

S55
—
S50
—
—
S51

M102
M137/M152
M138/M153
M145
M131
M135/M155

—
M57/H39
M58/H37
—
—
M59/H33

CFL150CATTCN
—
CFL250CATTCN
—
—
CFL400CATTCN

CFP150CATTCN
CFP175CATTCN
CFP250CATTCN
CFP320CATTCN
CFP350CATTCN
CFP400CATTCN

—
CFH175CATTCN
CFH250CATTCN
—
—
CFH400CATTCN

➊ To order fixture with guard, add suffix -G before voltage suffix.
➋ Fixtures furnished with trunnion and bolts, flexible coupling and fittings, and mounting accessory. The trunnion provides vertical adjustment and the mounting
accessory provides horizontal adjustment.
➌ Change voltage suffix -TT (120/277/347 V) to -MT for 120/208/240/277 V, -C2 for 208 V, -C3 for 240 V, -C6 for 480 V, or -C7 for 600 V, V
V CSA Certification only.

1292

Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

Code•Master 2™ HID Factory Sealed Floodlight Accessories
Marine (Outside Type). Explosionproof

Integrally Ballasted. 150 W, 250 W, 400 W HPS; 150 W, 175 W, 250 W, 320 W, 350 W, 400 W PSMH; 175 W, 250 W, 400 W MH V. Mogul Base.

Description
Junction Box for Horizontal or Vertical Mounting
Box has 1/2” opening for threading to Flexible Coupling, and two 3/4”
conduit openings (3/4 – 14NPT) and is furnished with one 3/4” close-up
plug. Locking screw for horizontal adjustment. Trunnion bolts furnished.
Aluminum, gray epoxy finish.

Catalog Number
AF-JB

Pole-Top Mount (on 2” Threaded Pipe)
Threads onto 2” pipe with tapered threads (2-11 – 1/2 NPT).  Includes
floodlight trunnion bolts. Locking screw for horizontal floodlight
adjustment. Aluminum, gray epoxy finish.

AF-SF

Has 180° horizontal adjustment – degree-marked.  Facilitates mounting
floodlight to crossarm or other flat surface, or to G-AM-8-WB Pole/Wall
Mounting Bracket (see photo below). Includes floodlight trunnion bolts.
Malleable iron, plated, chromate sealed, architectural bronze EPOXY finish.

G-AM-8-CA

Crossarm Mounting Bracket

Polyester Reflectors – 150 W through 400 W
Standard Dome
Deep Dome
30° Angle

CMR-4ST
CMR-4DD
CMR-4AN

Aluminum High Bay Reflectors – 150 W through 400 W
CMR-4HB

Flexible Coupling – 30” Long
Connects to 3/4” Fixture Unit hub (3/4 – 14 NPT) and to 1/2” 	
Junction Box or Pole-Top Accessory opening (1/2 – 14 NPT).

AF-EXL

Quartz Emergency Lamp for Pulse Start Metal Halide and High Pressure Sodium Fixtures
Fixtures can be supplied with a socket to accept a 150 W or 250 W, 120 V quartz lamp. 	
This D.C. bayonet base socket is in addition to the standard lamp socket, independent of the lighting fixture voltage.

Lighting

V CSA Certification only.
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

Lighting: Explosionproof — Floodlight

-E
HPS Smart Hot Restrike
Smart Hot Restrike will immediately restrike an HPS lamp when power is restored after a momentary power interruption. 	
The smart function removes the hot restrike ignitor from the circuit if the lamp burns out or is removed from the socket. 	
Eliminates starter failures caused by prolonged operation with cycling or failing lamps and simplifies finding their location, 	
reducing maintenance and repair costs.
Optional for 150 W fixtures (HPS only)
Add Suffix -SR
HPS Hot Restrike
Restrikes HPS lamp immediately when power is restored after a momentary power interruption.
Optional for 150 W fixtures (HPS only)
Add Suffix -R
HPS Smart Starter
Smart Starter for HPS and PSMH fixtures. Incorporates a 1-1/2-minute timer and performs as a conventional starter to normally 	
start lamp. Removes itself from circuit if lamp burns out or is removed from socket. Eliminates starter failures caused by 	
prolonged operation with cycling or failing lamps and simplifies finding their location, reducing maintenance and repair costs.
Optional for all fixture watts
Add Suffix -S
G-AM-8-CA Crossarm Mounting Bracket
Shown with G-AM-8-WB Pipe/Wall Mounting Bracket. 	
The G-AM-8-WB bracket is not furnished with fixtures.

1293

Code•Master 2™ HID Factory Sealed Floodlight Ballast and Fuse Data
Marine (Outside Type). Explosionproof

Integrally Ballasted. 150 W, 250 W, 400 W HPS; 150 W, 175 W, 250 W, 320 W, 350 W, 400 W PSMH; 175 W, 250 W, 400 W MH V. Mogul Base.
NEC:
Class 1, Division 1 and 2, Groups C, D
Marine Type Electric Fixtures
Outside Type (Salt Water)

Lamp
Watts

150

175

250

320

350

Ballast Amps
Pulse Start Metal Halide
Super CWA
Start
Operating
—
—
—
—
—
—
—
—
—
—
—
—
1.10
1.86
0.75
1.23
0.65
0.98
0.55
0.87
0.25
0.65
0.25
0.50
1.96
2.50
1.13
1.45
0.98
1.25
0.85
1.10
0.62
0.90
0.32
0.67
3.30
3.25
1.90
1.90
1.60
1.65
1.40
1.40
0.70
1.10
0.45
0.85
3.60
3.70
2.10
2.10
1.80
1.80
1.60
1.60
0.70
1.01
0.60
0.90
3.50
4.00
2.00
2.30
1.75
2.00
1.75
1.50
1.10
1.35
0.75
1.00

Metal Halide
CWA
Start
Operating
—
—
—
—
—
—
—
—
—
—
—
—
1.30
1.80
0.75
1.10
0.65
0.90
0.55
0.80
0.50
0.65
—
—
1.20
2.60
0.65
1.50
0.60
1.30
0.50
1.12
0.80
0.90
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
3.25
4.00
1.90
2.30
1.65
2.00
1.40
1.75
1.20
1.40
—
—

Fuse Kit Catalog Number
Fuse
Quantity
Required
1
2
2
1
1
2
1
2
2
1
1
2
1
2
2
1
1
2
1
2
2
1
1
2
1
2
2
1
1
2
1
2
2
1
1
2

HPS
CF-10
CF-5
CF-5
CF-5
CF-5
CF-3
—
—
—
—
—
—
CF-8
CF-5
CF-5
CF-5
CF-5
CF-2
—
—
—
—
—
—
—
—
—
—
—
—
CF-15
CF-8
CF-5
CF-5
CF-5
CF-5

PSMH
—
—
—
—
—
—
CF-5
CF-3
CF-3
CF-2
CF-2
CF-2
CF-8
CF-5
CF-5
CF-3
CF-3
CF-2
CF-8
CF-6
CF-5
CF-5
CF-5
CF-3
CF-10
CF-8
CF-5
CF-5
CF-5
CF-3
CF-10
CF-8
CF-5
CF-5
CF-5
CF-3

MH
—
—
—
—
—
—
CF-5
CF-3
CF-3
CF-2
CF-2
—
CF-8
CF-5
CF-5
CF-3
CF-3
—
—
—
—
—
—
—
—
—
—
—
—
—
CF-10
CF-8
CF-5
CF-5
CF-5
—

Lighting

Lighting: Explosionproof — Floodlight

400

Volts
120
208
240
277
347
480
120
208
240
277
347
480
120
208
240
277
347
480
120
208
240
277
347
480
120
208
240
277
347
480
120
208
240
277
347
480

High Pressure
Sodium ➊
Start
Operating
2.00
1.66
1.16
0.96
1.00
0.83
0.88
0.75
0.52
0.56
0.50
0.44
—
—
—
—
—
—
—
—
—
—
—
—
1.75
2.70
1.00
1.50
0.85
1.30
0.75
1.15
0.60
0.93
0.40
0.65
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
3.10
3.90
1.80
2.25
1.60
1.95
1.35
1.70
1.00
1.32
0.80
1.00

CEC: V
Class I, Division 1 and 2, Groups B, C, D
Class II, Division 1, Groups E, F, G
Class II, Division 2, Groups F, G
Class III
CSA 4X

Fuse Kit includes fuse, fuse holder and necessary hardware for field installation. Mounts easily in ballast body with one screw. Order one fuse for 120 and 277 V,
and 2 fuses for 208, 240 and 480 V. CF-2 = 2 amp; CF-3 = 3 amp; CF-5 = 5 amp; CF-6 = 6 amp; CF-8 = 8 amp; CF-10 = 10 amp
➊ 50 through 150 W HPS have H.P.F. High Reactance ballasts; 250 W and 400 W HPS have CWA ballasts.
V CSA Certification only.

1294

Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

Code•Master 2™ HID Factory Sealed Floodlight Dimensions
Marine (Outside Type). Explosionproof

Integrally Ballasted. 150 W, 250 W, 400 W HPS; 150 W, 175 W, 250 W, 320 W, 350 W, 400 W PSMH; 175 W, 250 W, 400 W MH V. Mogul Base.

Dimensions in Inches/Millimeters

2.95"/
74.9 mm

3.25"/
82.6 mm

2.38"/
60.5 mm
4.75"/
120.7 mm
4.75"/
120.7 mm

5.70"/
144.8 mm
5.00"/
127 mm Dia.

5.65"/
143.5 mm

4.94"/
125.5 mm

2.38"/
60.5 mm

36.44"/
925.6 mm

16.44"/
417.6 mm

15.94"/
404.9 mm

3.50"/
88.9mm
5.00"/
127 mm

11.50"/
292.1 mm

1.75"/
44.5 mm
/
80"
20..3 mm
528

1.50"/
38.1 mm
4.44"/
112.8 mm
0"/
13.0 mm
330.2

/
.6" m
23 .4 m
9
/
59 0.6"mm
2 .2
3
52

Lighting: Explosionproof — Floodlight

2.95"/
74.9 mm

18.63"/
473.2 mm

/
.0" m
12 .8 m
4
30

11.5"/
292.1 mm

5.00"/
127 mm Dia.

508 20"/
mm
R

11.50"/
292.1 mm

7.13"/
181.1 mm
53.0"/1346.2 mm Min.

1.75"/
44.5 mm
3.50"/
88.9 mm

2.94"/
74.7 mm Dia.

2.00"/
50.8 mm

13.0"/
330.2 mm

Weights
150 W

175 W

250 W

320 W

350 W

400 W

46 lb/21 kg

46 lb/21 kg

70 lb/32 kg

70 lb/32 kg

70 lb/32 kg

70 lb/32 kg

Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

Lighting

V CSA Certification only.

1295

Code•Master 2™ HID Factory Sealed Floodlight Photometric Data
Marine (Outside Type). Explosionproof

Typical Footcandle Values for Iso-Footcandle Curves. Data Based on 400 W HPS (50,000 Lumens) Clear Mogul Base Lamps.

400 W HPS Floodlight at 45° Angle with High Bay Reflector *

Lighting: Explosionproof — Floodlight

Distance in terms of mounting height

400W MH Floodlight at 45° Angle with High Bay Reflector

Mounting
Height
(feet)
15

FOOTCANDLE VALUES FOR ISO-FOOTCANDLE CURVES
A
52.52

B
43.34

C

D

31.00

17.05

E
10.23

F

G

H

I

Mounting
Height
(feet)

4.77

2.43

1.36

0.84

15

A

B

33.97

22.10

C
16.12

D

E

F

G

H

I

9.69

6.40

4.12

2.13

1.13

.67

2.31

1.20

.64

.38

.77

.41

.24

20

29.54

24.38

17.44

9.59

5.75

2.68

1.37

0.77

0.47

20

19.11

12.43

9.07

5.45

3.60

25

18.91

15.60

11.16

6.14

3.68

1.72

0.87

0.49

0.30

25

12.23

7.96

5.80

3.49

2.30

1.48

30

13.13

10.84

7.75

4.26

2.56

1.19

0.61

0.34

0.31

30

8.49

5.52

4.03

2.42

1.60

1.03

.53

.28

.17

35

9.65

7.96

5.69

3.13

1.88

0.88

0.45

0.25

0.15

35

6.24

4.06

2.96

1.78

1.18

.76

.39

.21

.12

40

7.39

6.10

4.36

2.40

1.44

0.67

0.34

0.19

0.12

40

4.78

3.11

2.27

1.36

.90

.58

.30

.16

.10

45°

45°
MH

MH

1.0MH

Lighting

FOOTCANDLE VALUES FOR ISO-FOOTCANDLE CURVES

1.0MH

* For 250 Watt HPS Clear, 30,000 Lumen lamp, multiply all FTC values by 0.60

1296

Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

EFL Series HID and Quartz Floodlights V
cCSAus. Explosionproof
Class I, Zone 1 & 2
Ex de IIB T1/T2/T3
Class I, Zone 1 & 2,
AEx de IIB T1/T2/T3
IP66 / 67

Applications
•	 Designed for large area lighting in industrial outdoor and indoor
explosionproof areas.
•	 Ideal for use in Zone 1 and 2 applications in the oil and gas
industry in such areas as refineries, pipelines and offshore
drilling rigs.

Features
•	 Fast and easy tubular lamp replacement via threaded entry at
the end of the fixture. Suitable for HPS and HPI-T MH lamps
only. Other lamps require lens cover removal for servicing.
•	 Lamp holder can be easily field adjusted for either a narrow or
wide beam type.
•	 Thermally separated ballast provides for extended life.
•	 Easy, efficient wiring process due to a separate Ex-e terminal
chamber.
•	 Choice of mounting with a galvanized yoke bracket, fixed
horizontal brackets, two different sizes of tube/pole mount
brackets or without brackets for custom installation.
•	 Tempered safety glass lens is factory sealed into the cover
frame.
•	 Suitable for use in up to 131 °F/55 °C ambient temperatures.
•	 2 – M20 threaded cable entries for ease of wiring. Supplied c/w
one close-up plug and one Ex-e non-armored cable gland.
•	 One external 4mm2 and one 6mm2 earth/ground terminals.
•	 Universal mounting for vertical or horizontal positioning.
•	 Reversible hinge allows for fixture access from either side.
•	 Mogul Base Lamp is supplied as standard. Optional export
version would be supplied with E40 export socket.
•	 Highly polished internal Aluminium reflector.

Options
•	 Overhead diffuser. Black painted, galvanized steel. Suffix –D.
•	 Protective wire guard. Zinc plated steel. Suffix –G.
•	 Hot Restrike Igniter. Ignites a hot lamp shortly after a power dip
or outage extinguishes the lamp. Suffix –R.
•	 Safety Starter.	 Shuts off device in the event of a lamp failure.
Suffix –S.
•	 Additional wiring terminals. For 3 Phase loop in/out. Suffix –T.

Certifications and Compliances
•	 cCSAus: LR25428

Standard Materials
•	
•	
•	
•	

Housing and door: copperfree marine grade aluminum alloy
Lens: tempered safety glass
Reflector: highly polished aluminium
Closure bolts: 316 stainless steel

Standard Finishes
•	 Exterior finish: Housing and door: gray polyester epoxy.

EFL

H

EFL Series:
Explosionproof
Floodlights

40
     Wattage:
10 - 1000W Quartz Halogen
15 - 150W HPS/MH
17 - 175W MH/PSMH
20 - 200W PSMH
25 - 250W HPS/MH
40 - 400W HPS/MH
50 - 500W Quartz Halogen

Lamp Type:
H - Metal Halide/ Mercury Vapor
L - High Pressure Sodium
P - Pulse Start Metal Halide
Q - Halogen

B

TT

L

HID Ballast Type & Voltage
TT - CWA for 120/277/347V
MT - CWA for 120/208/240/277V
XP - CWA for 120/220-240V 50 Hz
C5 - CWI for 480V
C6 - CWI for 600V
A1 - No Ballast - Quartz Only

Mounting:
                       Accessory Options:
B - Galvanized Yoke Bracket (Std. Offering)
D - Overhead Diffuser
H - Set of Horizontal Fittings
G - Protective Wire Guard
C1 - Clamp Bracket. For 1-1/4” – 1-1/2” Tube
L - Lamp Included (HIDOnly)
C2 - Clamp Bracket. For 2” Tube
R - Protected Hot R Strike
N - No Mounting Hardware Supplied
S - Safety Starter (not required
with R)

Lighting

V cCSAus Certification.
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

Lighting: Explosionproof — Floodlight

Catalog Numbering Guide

1297

EFL Series HID and Quartz Floodlights V
cCSAus. Explosionproof
Class I, Zone 1 & 2
Ex de IIB T1/T2/T3
Class I, Zone 1 & 2,
AEx de IIB T1/T2/T3
IP66 / 67

T Code

T Code

104 °F/40 °C

131 °F/55 °C

Input Voltages

Fixture
Wt.

Vol.

Catalog
Number

150 W

T3

T3

120/277/347 V 60Hz

60

3

EFLH15B-TTCN *

250 W

T3

T3

120/277/347 V 60Hz

62

3

EFLH25B-TTCN

400 W

T3

T3

120/277/347 V 60Hz

66

3

EFLH40B-TTCN

175 W

T3

T3

120/277/347 V 60Hz

62

3

EFLP17B-TTCN *

200 W

T3

T3

120/277/347 V 60Hz

62

3

EFLP20B-TTCN *

250 W

T3

T3

120/277/347 V 60Hz

25

3

EFLP25B-TTCN *

400 W

T3

T3

120/277/347 V 60Hz

66

3

EFLP40B-TTCN *

150 W

T3

T3

120/277/347 V 60Hz

60

3

EFLL15B-TTCN

250 W

T3

T3

120/277/347 V 60Hz

62

3

EFLL25B-TTCN

400 W

T3

T3

120/277/347 V 60Hz

66

3

EFLL40B-TTCN

Lamp sockets rated 	
125-250 Vac

71

3

EFLQ50B-A1CN

71

3

EFLQ10B-A1CN

Fixture Ordering
Supplied Std. w/ Yoke Mtg.
Metal Halide/Mercury Vapor

Pulse Start Metal Halide

High Pressure Sodium

Tubular Quartz Halogen
500 W

T1

T1

1000 W

T1

T1

Voltages — Add Suffix Below to Catalog Number
Volts

120

208

220

240

277

347

480

CWA

-MT

-MT

-

-MT

-MT

-

CWI

-C1

-C2

-

-C3

-

-C5

-C6

50 Hz CWA

-XP

-

-XP

-XP

-

-

-

-A6

600
‡

-C7

Lighting: Explosionproof — Floodlight

Accessories and Replacement Parts
Size
In/mm

Catalog Number

Galvanized Steel Hinged Bracket

Catalog Number
Clip on Diffuser

PNTB1
Pole Mounting Brackets

PND1
Protective Guard

1-1/4” to 1-1/2”/	
31.8 mm to 38.1 mm

PNPB115

2”/50.8 mm

PNPB120

PNG1

Horizontal Fixed Mounting Bracket

Lighting

PNHB1
* Depending on availability of tubular type lamps, may require removal of lens cover for servicing.
‡ Supplied as export voltage only. Not suitable for CEC applications
V cCSAus Certification.

1298

Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

EFL Series HID and Quartz Floodlight Dimensions and Photometric Data V
cCSAus. Explosionproof

Dimensions in Inches/Millimeters

6.25”/
158.8 mm

16.77”/426.0 mm

13.45”/341.6 mm

28.54”/724.9 mm

Photometric Data

Polar curves for a 1000 lm flux, according to NF C 71-120
Luminaire symbol according to NF C 71-121
250W halide Narrow Beam
Efficiency 68.3%
NF C 71-121: 0,68B

250W halide Wide Beam
Efficiency 67.9%
NF C 71-121: 0,68C

Candela
Distribution
0-180 90-270
505
505
515
499 150°	 120°
512
469
501
403
476
312
453
248
427
190
394
146
368
117
290
97
160
12
51
7
15°
34
4 0°	
15
4
6
4

400W halide Narrow Beam
Efficiency 49.3%
NF C 71-121: 0,49C

Candela
Distribution

105°
90°
75°
60°
45°

30°

0
5
10
15
20
25
30
35
40
45
50
55
60
65
70

0-180 90-270
301
301
303
318 150°	 120°
299
342
294
387
287
382
286
306
271
237
231
208
172
186
133
140
83
104
48
18
15°
34
8 0°	
23
6
6
6

400W halide Wide Beam
Efficiency 46.7%
NF C 71-121: 0,46C

Candela
Distribution

105°
90°
75°
60°
45°

30°

0
5
10
15
20
25
30
35
40
45
50
55
60
65
70

0-180 90-270
217
217
210
219 150°	 120°
218
231
223
205
238
193
255
148
266
132
263
130
244
116
201
104
136
37
85
15
15°
51
8 0°	
28
6
5
4

Candela
Distribution

105°
90°
75°
60°
45°

30°

0
5
10
15
20
25
30
35
40
45
50
55
60
65
70

0-180 90-270
105
105
104
106 150°	 120°
108
130
124
165
148
177
167
183
165
147
142
127
116
113
74
115
52
103
48
40
15°
44
13 0°	
34
9
18
6

105°
90°
75°
60°
45°

30°

Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

Lighting

* 400 W MH: Efficiency rate lower than 250 W due to thermal deflector between glass and lamp, requested for T3.
V cCSAus Certification.

Lighting: Explosionproof — Floodlight

0
5
10
15
20
25
30
35
40
45
50
55
60
65
70

Longitudinal
Transverse

1299

PB, PC & PL Series

Floodlights – Flameproof
Zone 1 & 2 - 21 & 22
II 2 GD
ATEX / IECEx
IP66 or IP66/67 - IK10

Applications
•	 Designed for large area lighting in industrial outdoor and indoor	
hazardous areas.
•	 Ideal for use in Zones 1 and 2 and 21 and 22 in the oil and gas
industrysuch as: refineries, pipelines, warehouses, offshore
platforms and drilling rigs.

Type PB

Lighting: Explosionproof — Floodlight

Features
•	 Gray epoxy painted light marine grade aluminum housing 	
and door.
•	 Fast and easy lamp replacement via threaded cover on the 	
side of the fixture (Types PB and PC). The cover is fitted with 	
a short safety chain.
•	 Lampholder can be easily field-adjustable for either a narrow 	
or wide beam.
•	 Fixtures operate safely in high ambient temperatures up 	
to +131°F/55°C and in low ambient temperature up to -40 °F/40 ºC  (-13 °F/-25 ºC for PC type and -40 °F/-40 ºC for PL type).
•	 Electrical components (ballast, ignitor and capacitor) are
thermally separated from the lighting compartment with a
bulkhead (Type PB) or with an insulating protection 	
(Types PC and PL), providing extended life.
•	 Easy and efficient wiring due to separate Ex e terminal box 	
with wiring onto 2 captive terminals 2 x .009 in²/6 mm2; 2
internal earth terminals capacity .009 in2/6 mm2 and 1 external
earth terminal capacity .006" in²/4 mm2.
•	 2 x .79"/20 mm clearance holes throughwire cable entries
supplied with:
	 — One Ex e unarmored cable gland 	
		 (sealing dia. .26" to .57"/6.5" to 14.5 mm)
	 — One blanking plug
	 — Two M20 locknuts.
•	 For use with either tubular or ellipsoidal shape lamps. 	
See ordering information for details.
•	 Choice of mounting with galvanized hinged bracket fixed
mounting or tube/pole mounting with galvanized brackets.
•	 Toughened glass factory-sealed into the floodlight body 	
(Types PC and PL) or factory-sealed into the cover frame 	
(Type PL).
•	 Operates in any position (except Type PL, to be used only 	
for wall-mounting or down lighting applications).
•	 Reversible hinge allows for fixture access from either side.
•	 E40 or H3 lampholders for the 2 x 70 W Vac/Vdc 	
halogen version.
•	 Internal symmetric reflector.

Standard Materials
•	 Housing and door: copperfree marine-grade aluminum 	
alloy
•	 Lens: toughened safety glass
•	 Reflector: bright highly polished aluminum
•	 Bolts: stainless steel bolt
•	 Cable gland and blanking plug: polyamide
•	 Locknut: nickel plated brass

Standard Finishes
•	 Housing and door: gray epoxy powder paint

Type PC

•	 Screwed-on overhead diffuser out of galvanized steel with 	
black painting (see accessories).
•	 Screwed-on zinc-coated protection guard for Types PB and PC
(see accessories).
•	 1000 W HP Sodium (Type PL) with separate Ex d housing 	
for ballast.

Certifications and Compliances
•	
•	
	
	
	
•	
	
	
	
•	
•	
•	
•	
•	
•	
•	
•	
•	
•	
•	

Certification Type: PJd
Zone 1 - 2
— Conforming to ATEX 94/9/CE: CE 0081
II 2 G
— ATEX/IEC Protection: Ex de IIB (Type PB et PL) 	
		 Ex de IIC (Type PC)
— T Rating: See Tables
Zone 21 - 22
— Conforming to ATEX 94/9/CE: CE 0081
II 2 D
— ATEX/IEC Protection: Ex tD A21
— Surface Temperature: See tables
Ambient Temperature:  -4 °F/-20 °C ≤ Ta ≤ +131 °F/55 °C (Type
PB and PC) (-13 °F/-25 °C for PC Type as an option) -40 °F/-40
°C ≤ Ta ≤ +131 °F/55 °C (Type PL)
CE Declaration of Conformity: 50207
ATEX Certificate: LCIE 99/ ATEX 6002
IECEx Certificate: IECEx LCI 04.0020
Other Certifications: GOST
Index of Protection (solid & liquid): IP66 (Type PB)	
	IP66/67 (Types PC and PL)
Impact Resistance (shock): IK10
Ex Standards	 EN / IEC 60079-0; 60079-1; 60079-7;
61241-0; 61241-1
Product Standards: EN / IEC 60598-1
EMC Standards: EN / IEC 55015; 61547
Other Standards: EN / IEC 60529 (IP); 62262 (IK)

North American CEC/NEC Certification:
•	
	
•	
•	

AEx/Ex de IIB IP 66 (Type PB only) cCSAus Ex de IIB IP 66
(Type PB only).
175 W Metal Halide and Pulse Start Metal Halide.
Safety starter.

Lighting

Options:
•	 Other voltages, please contact your sales representative.
•	 Terminal block with 2 more terminals for wiring with 3 phases 	
plus Neutral in 380/415 V (loop in/loop out wiring possible): add 	
suffix -T at the end of the catalog number.

1300

Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

PB, PC & PL Series

Floodlights – Flameproof
Zone 1 & 2 - 21 & 22
II 2 GD
ATEX / IECEx
IP66 or IP66/67 - IK10

Order using catalog numbering guide below or select catalog number from tables on following pages.
Catalog Numbering Guide
PB

A

H

Series:
PB - IIB
PC - IIC
PL - IIB Low Temperature
Rating ➍

15

Lamp Type:
H - Metal Halide
L - Sodium
M - Mercury Vapor
Z - Halogen

Zone 1, 2, 21 and 22
ATEX/IEC Certified

XJ

B

Voltage:
XJ	 -	 230/240 Vac 50 Hz (Magnetic Ballast)
XC	-	 230 Vac 50 Hz (Magnetic Ballast) ➋
XA	-	 220 Vac 50 Hz (Magnetic Ballast) ➋
BT	-	 24 Vac/Vdc ➊
Lamp Power:
70 - 2 x 70 W Halogen ➊
15 - 150 W
25 - 250 W
40 - 400 W
50 - 500 or 1000 W Halogen
60 - 600 W ➎
1K - 1000 W ➏

Options:
B	 -	 Hinged Bracket 	
Included
T	 -	 Extra 	
Terminals ➌
C	 -	 -25°C Ambient
Temperature ➐

Temperature Rating Chart: Types PB - PC
Lamp Wattage
2 x 70 W - H3 ➊
150 W Sodium
250 W Sodium
250 W Metal Halide
250 W Mercury Vapor
400 W Sodium
400 W Metal Halide
400 W Mercury Vapor
600 W Sodium
500 W Halogen
1000 W Halogen

Gas Temperature Rating According to Ta
+104°F/40°C
+122°F/50°C
+131°F/55°C
T4
T4
T3
T3
T3
T3
T3
T3
T2
T2
T1

T4
T3
T3
T3
T3
T3
T3
T3
T2
T2
T1

T4
T3
T3
T3
T3
T3
T3
T3
T2
T2
T1

Dust
Surface Temperature °F/°C
266/130
293/145
383/195
387/197
381/194
372/189
379/193
383/195
495/257
513/267
712/378

Lamp Wattage
150 W Sodium
250 W Sodium
250 W Metal Halide
250 W Mercury Vapor
400 W Sodium
400 W Metal Halide
400 W Mercury Vapor
600 W Sodium
500 W Halogen
1000 W Halogen

Gas Temperature Rating According to Ta
+104°F/40°C
+122°F/50°C
+131°F/55°C
T4
T3
T3
T4
T3
T3
T3
T3
T3
T3
T3
T3
T4
T3
T3
T3
T3
T3
T3
T3
T3
T2
T2
T2
T2
T2
T2
T1
T1
T1

Lighting: Explosionproof — Floodlight

Temperature Rating Chart: Types PL
Dust
Surface Temperature °F/°C
293/145
293/145
387/197
381/194
291/144
379/193
383/195
495/257
513/267
712/378

Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

Lighting

➊ Only for IIB Version - 2 x 70 W Halogen 24 Vac/Vdc.
➋ Only for IIB Low Temperature Rating Version Type PL.
➌ 3 Phase + Neutral.
➍ Only for 250 W and 400 W Versions.
➎ Only Sodium for PC Series (IIC).
➏ Only Sodium for PL Series + Seperate Gear Box.
➐ Only IIC Version.

1301

PB, PC & PL Series

Floodlights – Flameproof
Zone 1 & 2 - 21 & 22
II 2 GD
ATEX / IECEx
IP66 or IP66/67 - IK10

Lamp
Wattages

Lampholder

Voltage
(+/-10%)

Lamp Type
Ellipsoidal Tubular

Weight
lbs/kgs

Volume
in³/dm³

Catalog
Number

Ex de IIB Floodlight - PB Series
High Pressure Sodium
150 W

E40

230/240 V 50 Hz

x

x

65/29.3

4847/79.4

PBAL15XJB

250 W

E40

230/240 V 50 Hz

x

x

67/30.3

4847/79.4

PBAL25XJB

400 W

E40

230/240 V 50 Hz

–

x

70/31.8

4847/79.4

PBAL40XJB

Mercury Vapor
250 W

E40

230/240 V 50 Hz

x

x

65/29.3

4847/79.4

PBAM25XJB

400 W

E40

230/240 V 50 Hz

–

x

66/29.8

484779.4

PBAM40XJB

Metal Halide
250 W

E40

230/240 V 50 Hz

x

x

67/30.3

4847/79.4

PBAH25XJB

400 W

E40

230/240 V 50 Hz

–

x

70/31.8

4847/79.4

PBAH40XJB

–

x

58/26.3

4847/79.4

PBAZ50B

24 Vac/Vdc 50 Hz

–

–

60/27.3

4847/79.4

PBAZ70BTB *

Halogen
500/1000 W

E40

2 x 70 W

H3

Ex de IIC Floodlight - PC Series
High Pressure Sodium
150 W

E40

230/240 V 50 Hz

x

x

64/29.0

6374/104.4 PCAL15XJB

250 W

E40

230/240 V 50 Hz

x

x

66/30.0

6374/104.4 PCAL25XJB

400 W

E40

230/240 V 50 Hz

–

x

71/32.0

6374/104.4 PCAL40XJB

600 W

E40

230/240 V 50 Hz

–

x

77/35.0

6374/104.4 PCAL60XJB

250 W

E40

230/240 V 50 Hz

x

x

66/30.0

6374/104.4 PCAM25XJB

400 W

E40

230/240 V 50 Hz

–

x

67/30.5

6374/104.4 PCAM40XJB

Mercury Vapor

Lighting

Lighting: Explosionproof — Floodlight

Metal Halide
250 W

E40

230/240 V 50 Hz

x

x

66/30.0

6374/104.4 PCAH25XJB

400 W

E40

230/240 V 50 Hz

–

x

71/32.0

6374/104.4 PCAH40XJB

–

x

60/27.0

6374/104.4 PCAZ50B

Halogen
500/1000 W

E40

Ex de IIB Floodlight - PL Series
High Pressure Sodium
250 W

E40

230/240 V 50 Hz

x

x

83/37.5

6374/104.4 PLAL25XJB

400 W

E40

220 V 50 Hz

x

x

83/37.5

6374/104.4 PLAL40XAB

–

x

75/34.0

6374/104.4 PLAZ50B

Halogen
500/1000 W

E40

Note : Floodlights supplied with hinged mounting bracket, 1 plug, 1 M20 cable gland (dia. 0.26” to 0.57”/6.5 to 14.5 mm). Lamps are not included.
* Supplied with 2 x 70 W H3 bulbs, 24 Vac/Vdc

1302

Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

PB, PC & PL Series Accessories and Spare Parts

Floodlights – Flameproof
Zone 1 & 2 - 21 & 22
II 2 GD
ATEX / IECEx
IP66 or IP66/67 - IK10

Type

Catalog Number

Galvanized Steel Hinged Brackets
Type PB

PBHBG

Type PL

PLHBG

Type PC

PCHBG

Pole/Tube Mounting Galvanized Steel Brackets
Type PB/PL

Type PC

1-1/4" to 1-1/2"

PNHC49G

2"

PNHC60G

1-1/4" to 1-1/2"

PCHC49G

2"

PCHC60G

Flat Surface Mounting Galvanized Steel Brackets
Type PB/PL

PNSBG

Type PC

PCSBG

Tubular

LM400E40

Type PB

PBGDG

Type PC

PCGDG

Type PB

PBPGZ

Type PC

PCPGZ

Type PC only

PCVG

400 W Mercury Vapor Lamp
Screwed-on Overhead Diffuser

Screwed-on Protective Guard

Lighting: Explosionproof — Floodlight

Visor (secured with 2 screws)

Lighting

Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

1303

PB, PC & PL Series Dimensions

Floodlights – Flameproof

Type PB

Type PC

Hinged Bracket Mounting

Hinged Bracket Mounting
16.40"/
416.5 mm
5.91"/
150 mm

10.43"/
265 mm

5.91"/
150 mm

29.53"/
750 mm

16.77"/
426 mm
6.22"/
158 mm

8.58"/
218 mm

11.81"/
300 mm

Flat Surface Mounting
13.43"/
341 mm

14.763"/
375 mm

1.97"/
50 mm

Flat Surface Mounting

Pole Mounting

25.75"/
654 mm
13.66"/
347 mm

Pole Mounting

Flat Surface Mounting

Quick access to
lamp

9.84"/
250 mm

14.90"/378.5 mm

Quick access to
component with
threaded cover

13.92"/353.5 mm

1.97"/
50 mm

4 x Ø0.49"/
12.5 mm

15.95"/396 mm

23.11"/587 mm

15.55"/395 mm

Pole Mounting

Lighting

Lighting: Explosionproof — Floodlight

Type PL
Hinged Bracket Mounting

1304

Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

PB, PC & PL Series Photometric Data

Floodlights – Flameproof

Longitudinal
Transverse

Polar curves for a 1000 lm flux, according to NF C 71-120
Luminaire symbol according to NF C 71-121
Narrow beam Metal Halide 250 W
Efficiency 68.3%
NF C 71-121: 0.68B

Narrow beam Metal Halide 400 W
Efficiency 49.3%
NF C 71-121: 0.49C

Candela Distribution

Candela Distribution

0-180 90-270

0-180 90-270

0

505

505

5

515
499
Degrees

10

512

469

15

501

403

20

476

312

25

453

248

30

427

190

35

394

146

40

368

117

45

290

97

50

160

12

55

51

7

60

34

4

65

15

4

70

6

4

0

217

105°

5

90°

10

210
219
Degrees

150°	 120°

75°
60°
45°

30°
0°	

15°

Wide beam Metal Halide 250 W
Efficiency 67.9%
NF C 71-121: 0.68C

231

15

223

205

20

238

193

25

255

148

30

266

132

35

263

130

40

244

116

45

201

104

50

136

37

55

85

15

60

51

8

65

28

6

70

5

4

0-180 90-270
0

417

105°

5

406
418
Degrees

90°

10

419

399

15

419

330

20

408

266

25

398

218

30

371

177

35

344

142

40

295

115

45

213

98

50

135

12

55

68

7

60

34

4

65

16

3

70

5

3

150°	 120°

75°
60°
45°

30°
0°	

15°

150°	 120°
105°
90°
75°
60°
45°

30°
0°	

15°

Candela Distribution
0-180 90-270
0
105
105
Degrees
5
104
106
10
108
130
15
124
165
20
148
177
25
167
183
30
165
147
35
142
127
40
116
113
45
74
115
50
52
103
55
48
40
60
44
13
65
34
9
70
18
6

417

150°	 120°
105°
90°
75°
60°
45°

30°
0°	

15°

Wide beam Halogen 1000 W
Efficiency 57.7%
NF C 71-121: 0.57C
150°	 120°
105°
90°
75°
60°
45°

30°
0°	

15°

Candela Distribution
0-180 90-270
0
251
251
Degrees
5
244
255
10
247
272
15
245
293
20
237
306
25
229
262
30
213
213
35
194
188
40
163
161
45
120
133
50
82
105
55
52
18
60
35
8
65
20
5
70
8
5

150°	 120°
105°
90°
75°
60°
45°

30°
0°	

Lighting: Explosionproof — Floodlight

0
5
10
15
20
25
30
35
40
45
50
55
60
65
70

218

Candela Distribution

Wide beam Metal Halide 400 W
Efficiency 46.7%
NF C 71-121: 0.46C

Candela Distribution
0-180 90-270
301
301
Degrees
303
318
299
342
294
387
287
382
286
306
271
237
231
208
172
186
133
140
83
104
48
18
34
8
23
6
6
6

217

Narrow beam Halogen 1000 W
Efficiency 59.2%
NF C 71-121: 0.59B

15°

Lighting

* 400 W Metal Halide: Efficiency rate lower than 250 W due to thermal deflector between glass and lamp, requested for T3.
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

1305

Explosionproof Floodlights

150 W, 300 W Reflector Incandescent
For 150 W PAR-38 or R-40 reflector lamps:
Class I, Groups C, D

For 300 W R-40 reflector lamps:
Class I, Group D

Applications
•	 Class I, Groups C and D locations such as aircraft service
areas, oil and gas loading docks, distilleries.

Features
•	 Floodlights feature rugged, lightweight cast aluminum
construction and are factory wired and sealed — no external
seals are required. Choice of lamp types provides various
distribution patterns. Use medium base 150W PAR-38, R-40 or
300W R40 reflector lamps.
•	 Easy to carry, portable model with wheelbase has  handle for
convenient carrying, built-on wrench allowing 135° vertical
adjustment. Weighs 19 lbs/8.6 kgs.
•	 External cable on portable wheelbase unit (not furnished)
should be 3-conductor No. 16 A.W.G. type S or SO rubber
covered cable. Service end of cord should be equipped with a 	
2-wire, 3-pole explosionproof plug for connecting to an
explosionproof receptacle.
•	 Terminal block has pressure terminal for connecting rubber
covered cable to floodlight. Cable Connector takes a .375”
to .500”/9.5 to 12.7 mm outside diameter cord. Sizes up to
.625”/15.9 mm diameter are available on special order.
•	 Permanent base model has explosionproof junction wiring
chamber with 3/4”/19.1 mm horizontal feed-thru hubs. Vertical
adjustment to 135°; horizontal to 345°.

GEFWB-30

Standard Materials
•	 Housing: cast aluminum
•	 Yoke: high-strength aluminum alloy
•	 Lens: thermal shock and impact resistant glass

Standard Finishes
•	 Floodlight housing, wheelbase, yoke and wiring compartment:
aluminum enamel finished

Certifications and Compliances

Lighting

Lighting: Explosionproof — Floodlight

•	 UL Standard: UL 1598, UL 844
•	 UL Listed: E10794
•	 Copperfree aluminum alloy and stainless steel construction
withstands 500 hours of salt-spray test. Per MIL-F-8115C

GEFJB-30

EF Series Explosionproof Floodlights
For 150W incandescent medium base PAR-38 (T3C) projector spot or flood, or 150W or 300W incandescent medium base R-40 (T2C)
reflector spot or flood
Description

Catalog Number

Portable Flood with Wheelbase and Handle. Accommodates .375”—.500”/9.5 mm cable.

G-EFWB-30

Permanent Base Floodlight, for .314”/8.0 mm conduit

G-EFJB-30

†

† Can be furnished to accommodate cable sizes to .625”/15.9mm Dia. on special order. Cable must be ordered separately.

1306

Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

Explosionproof Floodlight Dimensions
150 W, 300 W Reflector Incandescent

Dimensions in Inches/Millimeters
Wheelbase Floodlight (GEFWB-30)

Permanent Base Floodlight (GEFJB-30)

13.19"/
335.0 mm

10.5"/
266.7 mm

16.75"/425.5 mm
17.5"/444.5 mm

.75"/19.1 mm Hub each side

12"/
304.8 mm

3.25"/
82.6 mm

4.75"/120.7 mm

5.63"/143.0 mm

Lighting: Explosionproof — Floodlight

2.75"/
69.9 mm

G-EFJB-30
Base Dimensions

Lighting

Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

1307

Code•Master™ Factory Sealed Strobe Luminaires

Lighting: Explosionproof — Visual Signal

Lighting

Explosionproof, Dust-Ignitionproof
Class I, Division 1 and 2, Groups C, D
Class I, Division 2, Groups A, B
Class II, Division 1 and 2, Groups E, F, G
Class III	
NEMA 3R, 4X

Suitable for Wet Locations
Marine Outside Type (Saltwater)

Applications
•	 Code•Master Explosionproof Strobe fixtures are designed to
provide safe operation in the presence of hazardous gases,
vapors or dusts, defined by the National Electrical Code as
Class I, Groups C and D; and Class II, Groups E, F and G.
•	 For use in hazardous locations such as plants where plastics,
paints, thinners and petrochemicals are manufactured.
•	 Also used in areas where audible signals cannot be heard, to
warn of unsafe conditions and for other communication needs.

Features
•	
•	
•	
•	
•	
•	

•	
•	
•	

•	
•	
•	
•	
•	
•	

Fixtures operate safely in high ambient temperatures.
Minimum operating temperature is -13 °F/-25 °C.
Available for fire alarm hearing impaired.
65 flashes per minute.
Fixtures are complete with lamp.
Patented “wireless” design. Threading of fixture unit 	
onto mounting hood makes electrical connection. The 	
only wiring required is attaching two wires to connection 	
block in mounting hood.
Connection block is easily wired: (a) loosen two screws, (b)
make wire connections; and (c) re-position connection block.
Safe, easy servicing without disconnecting any wiring.
“Wireless” fixture unit threads off mounting hood for convenient
servicing or for immediate replacement with a “stand by” unit.
Acme double lead threads speed installation and fixture removal
from mounting hood. Only half as many turns are required as for
single lead threads. The threads do not stick or gall, eliminating
problems often encountered with single lead threads during
fixture unit removal.
All threaded joints are flame-tight.
Factory installed lens available in five colors: red, amber, blue,
green and clear (factory installed).
Factory sealed. External seals are not required.
Heat- and impact-resistant globes have smooth dust-resistant
exterior.
Fixture is suitable for mounting globe up or globe down utilizing
pendant, ceiling or wall bracket type mounts.
Optional guards protect globes from damage.

Fixture (shown with optional guard) are suitable for mounting in
any position including globe up or globe down utilizing pendant,
ceiling or wall-bracket type mounts.

Standard Materials
•	 Fixture housing, mounting hoods and guards: copperfree (4/10
of 1% max.) aluminum
•	 Globes: prismatic glass
•	 Screws: Stainless steel (3)

Standard Finishes
•	 Fixture housing, guards and mounting hoods: epoxy power 	
coat finish, electrostatically applied for complete, uniform
corrosion protection

Certifications and Compliances
•	
•	
•	
•	

UL Listed: E212210
UL Standard: 1203
UL Standard: 1638 Visual Signaling Appliances
UL Standard: 1971 Visual Signaling Equipment has been
investigated for fire protective signaling services to alert hearing
impaired persons. This signaling equipment is intended to be
used in conjunction with Listed compatible units and devices.
Visual signaling equipment Listed in this category is intended to
be used in the “Public Operating Mode” as defined in NFPA 72

1308

Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

Code•Master™ Factory Sealed Strobe Luminaires
Explosionproof, Dust-Ignitionproof

Lighting

Class I, Division 1 and 2, Groups C, D
Class I, Division 2, Groups A, B
Class II, Division 1 and 2, Groups E, F, G
Class III	
NEMA 3R, 4X

Suitable for Wet Locations
Marine Outside Type (Saltwater)

Catalog Numbering Guide
CS

S

P

Series:
CS - Code•Master Signal

75

120AC

Mounting Hood:
P - Pendant
B - Wall bracket
C - Ceiling

Type:
S - Strobe

CL

P

Voltage Current:
120 AC - 120 Vac
240 AC - 240 Vac
250 DC - 250 Vdc
2030 DC - 20-30 Vdc ➊
24 DC - 24 Vdc ➌
Hub Size:
75 – 3/4”

Options:
P - Hearing 	
Impaired 	
(UL1971)	
(Strobe Only)
G - Guard
Globe:
CL - Clear
AM - Amber ➋
BL - Blue ➋
GR - Green ➋
RE - Red ➋

Thermal Suitability of Code-Master Strobe Fixture
Ambient
Temp.
°F/°C

Class I, Division 1 and 2
Groups C & D

Class I, Division 2
Groups A & B

Class II, Division 1 & 2
Class III

104/40

T6

T2B

T4A

131/55

T6

T2B

T4A

149/65

T6

T2A

T4

Operating Temperatures
“T” Numbers Represent the Maximum Internal Temperature for Class I, Division 2 Locations; Maximum Surface Temperature for
Class I, Division 1 Locations; and Maximum Surface Temperature Under Dust Blanket for Class II, Division 1 Locations.
“T”
Number

T1

350

325

T2

T2A

T2B

T2C

T2D

T3

T3A

T3B

T3C

T4

T4A

T5

T6

Temp.
Range
(°F)

664842

619662

574617

538572

502536

448500

421446

394419

358392

331356

322329

277320

250275

214248

187212

185

Temp.
Range
(°C)

351450

326350

301325

281300

261280

231260

216230

201215

181200

166180

161165

136160

121135

101120

86100

85

NOTE: The maximum operating temperature of the fixture must not exceed the ignition temperature of the gas, vapor or dust to be encountered per the National
Electrical Code.

➊ UL1971: Hearing-Impaired Strobe Only
➋ Not for use with UL1971 Strobe
➌ Diode Polarized (Current limiter supplied as standard).
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

1309

Lighting: Explosionproof — Visual Signal

Ordering Information
Order using catalog numbering guide below or select catalog number from tables on following pages.

Code•Master™ Factory Sealed Strobe Luminaires

Lighting: Explosionproof — Visual Signal

Lighting

Explosionproof, Dust-Ignitionproof
Class I, Division 1 and 2, Groups C, D
Class I, Division 2, Groups A, B
Class II, Division 1 and 2, Groups E, F, G
Class III	
NEMA 3R, 4X

Suitable for Wet Locations
Marine Outside Type (Saltwater)

Standard Strobes
Volts

Catalog Number ➊➌

Pendant — One Hub 3/4” NPT, Rigid Conduit
120 Vac

CSSP75120ACCL

240 Vac

CSSP75240ACCL

250 Vdc

CSSP75250DCCL

24 Vdc

CSSP7524DCCL ➋

120 Vac

CSSC75120ACCL

240 Vac

CSSC75240ACCL

250 Vdc

CSSC75250DCCL

24 Vdc

CSSC7524DCCL ➋

120 Vac

CSSB75120ACCL

240 Vac

CSSB75240ACCL

250 Vdc

CSSB75250DCCL

24 Vdc

CSSB7524DCCL ➋

120 Vac

CSST120ACCL

240 Vac

CSST240ACCL

250 Vdc

CSST250DCCL

24   Vdc

CSST24PDCCL ➋

Ceiling — Four Hubs 3/4” NPT, Three Close-Up Plugs, Rigid Conduit

Bracket — Four Hubs 3/4” NPT, Three Close-Up Plugs, Rigid Conduit

Fixture Unit Only — Less Mounting Hood

10.3 lb/4.7 kg

Weight

Hub Size (Inches)

Catalog Number

3/4

CAP75

Pendant Mounting Hood — One Hub 3/4” NPT, Rigid Conduit
2.0 lb/9.0 kg

Ceiling Mounting Hood — Four Hubs 3/4” NPT, Three Close-Up Plugs, Rigid Conduit
4.0 lb/1.8 kg

3/4

CAC75

Bracket Mounting Hood — Four Hubs 3/4” NPT, Three Close-Up Plugs, Rigid Conduit
6.0 lb/2.7 kg

3/4

CALB75

➊ Add -G suffix for optional guard.
➋ Diode polarized (current limiter supplied as standard).
➌ Catalog numbers shown are supplied with clear lens. To order colored lens, replace last digits of catalog number CL with AM for amber; BL for blue; GR for
green; and RE for red.

1310

Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

Code•Master™ Factory Sealed Strobe Luminaires
Explosionproof, Dust-Ignitionproof

Lighting

Class I, Division 1 and 2, Groups C, D
Class I, Division 2, Groups A, B
Class II, Division 1 and 2, Groups E, F, G
Class III	
NEMA 3R, 4X

Suitable for Wet Locations
Marine Outside Type (Saltwater)

Type Mounting

Volts

Catalog Number — UL1971: Hearing-Impaired ➊

20-30 Vdc

CSSP752030DCCLP

20-30 Vdc

CSSC752030DCCLP

20-30 Vdc

CSSB752030DCCLP

10.3 lb/4.7 kg

20-30 Vdc

CSST2030PDCCL

Weight

Hub Size (Inches)

Pendant — One Hub 3/4” NPT, Rigid Conduit

Ceiling — Four Hubs 3/4” NPT, Three Close-Up Plugs, Rigid Conduit

Fixture Unit Only — Less Mounting Hood

Fixture Unit Only — Less Mounting Hood

Catalog Number — UL1971: Hearing-Impaired

Pendant Mounting Hood — One Hub 3/4” NPT, Rigid Conduit
2.0 lb/9.0 kg

3/4

CAP75-1971

Ceiling Mounting Hood — Four Hubs 3/4” NPT, Three Close-Up Plugs, Rigid Conduit
4.0 lb/1.8 kg

3/4

CAC75-1971

Bracket Mounting Hood — Four Hubs 3/4” NPT, Three Close-Up Plugs, Rigid Conduit
6.0 lb/2.7 kg

3/4

CALB75-1971

➊ Only clear globes are available for UL1971 applications.

Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

1311

Lighting: Explosionproof — Visual Signal

Strobes for the Hearing Impaired

Code•Master™ Factory Sealed Strobe Luminaire Accessories

Lighting: Explosionproof — Visual Signal

Lighting

Explosionproof, Dust-Ignitionproof

Description

Weight Lbs/Kg

Catalog Number

1.0/0.5

CJGU-15

0.5/0.2

VPT-7

0.5/0.2

VPT-7P

Optional Aluminum Guard

Replacement Connection Block — Standard
For Non-Hearing-Impaired 	
CodeMaster Fixtures
Replacement Connection Block — UL1971: Hearing-Impaired
For Code-Master Fixtures for the
Hearing Impaired

Replacement Lamps
Fixture Type

Lamp Type

Voltage

Base Type

Catalog Number

Xenon

All

Octal Socket

S865

Strobe

1312

Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

Code•Master™ Factory Sealed Strobe Luminaire Family Tree and Dimensions
Explosionproof, Dust-Ignitionproof

Lighting

Ceiling
Four Hubs
Three Close-Up Plugs
3/4” NPT
CAC75	
CAC75-1971	

Lighting: Explosionproof — Visual Signal

	
	

Pendant
One Hub
—
3/4” NPT
CAP75	
CAP75-1971	

Bracket
Four Hubs
Three Close-Up Plugs
3/4” NPT
CALB75
CALB75-1971	

Fixture Unit With Globe
Strobe

120AC
240AC
250DC
     20-30DC
24DC

CSST120ACCL
CSST240ACCL
CSST250DCCL
CSST2030PDCCL ➊
CSST24PDCCL ➋

Optional Aluminum Guard
CJGU-15

Dimensions in Inches/Millimeters
Pendant

Ceiling

Wall Bracket

0.41"/
10.4 mm Dia.

Hub for .75"
NPT Conduit
4.00"/
101.6 mm

4.50"/
114.3 mm

4.00"/
101.6 mm

3.75"/
95.3 mm

4.50"/
114.3 mm
Dia.

5.92"/
150.4 mm

Hub for .75" NPT
Conduit Four Sides
13.15"/
334.0 mm

Hub For
2.46"/
62.5 mm

3/4” NPT 2” Wiring access

2.28"/
57.9 mm

cover both sides.
4.25"/
108.0 mm

4.92"/
125.0 mm Sq.
3.92"/
99.6 mm

1.23"/
31.2 mm
3.46"/
87.9 mm

1.79"/
45.5 mm

11.5"/
292.1 mm
13.75"/
349.3 mm

5.95"/
151.3 mm
13.88"/
352.6 mm

4.00"/
101.6 mm

4.92"/
125.0 mm

13.53"/
343.7 mm

12.38"/
314.5 mm

13.00"/
13.38"/ 330.2 mm
339.9 mm

13.75"/
349.3 mm

7.80"/
198.1 mm
7.80"/
198.1 mm

7.80"/
198.1 mm

➊ UL1971: Hearing-Impaired Strobe Only
➋ Diode polarized (current limiter supplied as standard).
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

1313

TCH Series Safety Flashlights

Increased Safety

Zone 1 & 2 - 21 & 22
II 2 GD
ATEX / IEC
IP66 (TCH1) IP66/68 (TCH2)

Lighting: Explosionproof — Portable

Lighting

Applications
•	 To provide maintenance staff with task specific portable 	
lighting in Zone 1 hazardous areas.
•	 Ideal for persons requiring task specific portable lighting 	
in refineries, oil and gas process and chemical plants.

Features
•	 Type TCH1:
— Luminescent switch facilitates locating flashlight in dark.
— Can be used to transmit a Morse code.
— Halogen version provides twice the lumen output of
incandescent lamps.
— Hook for hands free operation.
— Uses R20 or LR20 batteries (not included).
— Supplied with 1 lamp.
•	 Type TCH2:
— Dual optics (one at the end and one on the side) permitting:
	 - Focused beam for safe movement.
	 - Wide angle side beam for task specific focused lighting.
— Ergonomic design permits easy manipulation: 	
User can select one of the two beams with one hand.
— Two beams can be switched on separately and not
simultaneously.
— Should one lamp fail, the second lamp will still provide
illumination.
— Flashlight is stable when placed upright on a horizontal
surface.
— Pocket clip allows for hands free work.
— Luminescent ring allows easy locating of flashlight in dark.
— Suspension hook for hands free use.
— Uses 2 R20 or LR20 batteries (not included).
— Supplied with one halogen lamp for main beam and one
incandescent lamp for side beam.
— Supplied with one special opening tool.

Standard Material
•	 Type TCH1:
— Housing: shockproof and antistatic polyamide
— Internal reflector: polished
— Lens: polycarbonate
— Hardware: stainless steel
— Switch: luminescent
•	 Type TCH2:
— Housing: black polycarbonate
— Internal reflector: polished
— Lens: polycarbonate
— Hardware: stainless steel
— Ring: luminescent

Certifications and Compliances	
•	
	
	
	
	
	
	
	
	
	

	
	
Gas: Zones 1–2	
	
	
	
— Conforming to ATEX 94/9/CE: CE 0081
II 2 G
— ATEX/IEC Protection: Ex eib IIC 	
— Certification Type TCH1
		
- T Rating: T4
		
- Ambient Temperature: -4 °C/20 °C ≤ To ≤ + 104°F/40 °C
		
- CE Declaration of Conformity: 50259
		
- ATEX Certificate: LCIE 03 ATEX 6064
		
- IEC Certificate: LCIE Ex 03.010
		
- Ingress Protection (solid and liquid): IP66

1314

TCH1

TCH2

	 — Certification Type TCH2
	 		
- T Rating:
	 		
   -4 °F/20 °C ≤ To ≤ + 104 °F/40 °C: Incandescent PR6, 	
		
   Krypton PR102, Halogen HPR52, Halogen HPR01 = T4
	 		
   +104 °F/40 °C ≤ To ≤ + 131 °F/55 °C: Incandescent PR6, 	
		
   Krypton PR102, Halogen HPR01 = T4
	 		
   +104 °F/40 °C ≤ To ≤ + 131 °F/55 °C: Halogen HPR52 = 	
		
   T3
	 		
   Ambient Temperature: -4° F/-20 °C ≤ To ≤ + 131 °F/55 °C
	 		
- CE Declaration of Conformity: 50238
	 		
- ATEX Certificate: LCIE 02 ATEX 6229
	 		
- IEC Certificate: LCIE Ex 02.024
	 		
- Ingress Protection (solid and liquid): IP66/68 (25m)
•	 Dust: Zone 21-22	
	
	
	
II2 D
	 — Conforming to ATEX 94/9/CE: CE 0081
	 — ATEX/IEC Protection: Ex tD A21 	
	 — Certification Type TCH1
	 		
- Surface Temperature: 203°F/95 °C
	 		
- Ambient Temperature: -4°F/-20 °C ≤ To ≤ + 104°F/40 °C
	 		
- CE Declaration of Conformity: 50259
	 		
- ATEX Certificate: LCIE 03 ATEX 6064
	 		
- IEC Certificate: LCIE Ex 03.010
	 		
- Ingress Protection (solid and liquid): IP66
	 — Certification Type TCH2
	 		
- Surface Temperature: 266° F/130 °C
	 		
   Ambient Temperature: -4 °F/-20 °C ≤ To ≤ + 131 °F/55 °C
	 		
- CE Declaration of Conformity: 50238
	 		
- ATEX Certificate: LCIE 02 ATEX 6229
	 		
- IEC Certificate: LCIE Ex 02.024
	 		
- Ingress Protection (solid and liquid): IP66/68 (25m)
•	 Ex Standards: EN/IEC 60079-0; 60079-7; 60079-11; 61241-0;
61241-1
•	 Product Standards: EN/IEC 60598-1
•	 Other Standards: EN/IEC 60529 (IP)

Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

TCH Series Safety Flashlights

Increased Safety

Zone 1 & 2 - 21 & 22
II 2 GD
ATEX / IEC
IP66 (TCH1) IP66/68 (TCH2)

Ordering Information:
Number of
Battery Cells

Weight
lbs/kgs

Volume
in3/dm3

1

Incandescent
2.5 V – 0.3 A

2

0.88/0.4

207.6/3.4

1

Incandescent
3.7 V – 0.3 A

3

0.88/0.4

207.6/3.4

1

Halogen
2.8 V – 0.5 A

2

0.88/0.4

207.6/3.4

2

0.88/0.4

116.0/1.9

2

Incandescent
2.5 V – 0.3 A
Halogen
2.8 V – 0.5 A

Catalog
Number

Pack

TCH12C

2

TCH13C

2

TCH12H

2

TCH22M

1

Lighting: Explosionproof — Portable

Type of Lamps
(not included)

Lighting

Number of
lamps
(included)

Spare Lamps for Replacement (Lamp Holder P13,5S)
Rating

Catalog Number

Pack

Incandescent (PR6)

Type of lamp

2.5 V – 0.3 A

TCHL25C

10

Incandescent (PR6)

3.7 V – 0.3 A

TCHL37C

10

Halogen (HPR01)

2.8 V – 0.5 A

TCHL28H

10

Dimensions in Inches/Millimeters

1.1/28.0
28

48

1.4/35.0
35

TCH13C

27

Ø2.8/72.0
72

44

Ø2.8/70.0
70

60
TCH12C/H

213
8.4/213.0

244

9.6/244.0

Ø2.4/60.0

Ø2.4/60.0
60

182
7.2/182.0

44
Ø1.7/44.0

TCH22M

Photometric Data

Catalog Number TCH12C (at 25 meters) Incandescent
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

Catalog Number TCH13C (at 25 meters) Incandescent

1315

AHL and EHL Incandescent Factory Sealed Luminaires and Handlamps
Explosionproof

Suitable for use in Wet Locations.
AHL
Class I, Division 1 and 2, Groups C, D
Class II, Division 1 and 2, Groups F ➊, G
Class III

EHL
Class I, Division 1 and 2, Groups C, D

Lighting

Applications
•	 AHL general purpose explosionproof lighting fixture – an
A-51 fixture with handle assembly of hook and cable clamp.
CAUTION: For safe operation, the AHL fixture weight must be
supported by the hanger hook, not by the flexible cord, per the
National Electrical Code.
•	 EHL general purpose explosionproof portable handlamp. Only
5”/127 mm in diameter for ease of movement.

Lighting: Explosionproof — Portable

Features:
•	 AHL and EHL
	 – Equipped with connection block for ease of wiring 	
and relamping.
	 – Cable clamp diameters: AHL – .375” to .625”/9.5 mm to 15.9
mm; EHL – .406”/10.3 mm for 16-3 AWG.
	 – Heat- and impact-resistant glass globes.
•	 AHL
	 – Sturdy fixture with rugged hanging hook.
	 – Safety grounding – additional terminal furnished to connect to
grounding conductor.
•	 EHL
	 – Portability, with phenolic handle and non-sparking guard 	
with hook.
	 – Easy relamping – loosen setscrew, unscrew guard, remove
globe and insert lamp.
	 – Safety grounding – remove cable and clamp and make
connections to terminal (including one ground terminal) then
tighten clamp.

AHL

EHL

Standard Materials
•	
•	
•	
•	
•	
•	
•	

Globes: heat-and impact-resistant glass
AHL fixture unit, hook and guard: copperfree aluminum
AHL cable clamp: brass
EHL fixture body and handle: laminated phenolic
EHL handle: laminated phenolic
EHL hook: brass
EHL guard: copperfree aluminum

Standard Finishes
•	 AHL fixture unit, guard, handle and hook: two-coat 	
epoxy enamel
•	 AHL cable clamp: natural finish
•	 EHL fixture body: laminated phenolic
•	 EHL handle: phenolic
•	 EHL guard and hook: guard – natural finish; hook – zinc
electroplate and clear chromate
•	 EHL cable clamp: laminated phenolic

Certifications and Compliances
•	 UL Standard: UL 1598, UL 844
•	 EHL UL Listed: E59147
•	 CSA Certification: LR25428

Related Products
•	 The EHL handlamp may be used with AE Automatic TakeUp Reelites listed in the Specialty Products section and ECC
Cord Connector and Plugs and Receptacles in the Plug and
Receptacles section.

➊ To reduce the risk of ignition of hazardous atmospheres, do not use where electrically conductive dusts are present (most coal dusts are not electrically
conductive).

1316

Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

AHL and EHL Incandescent Factory Sealed Luminaires and Handlamps
Explosionproof

Suitable for use in Wet Locations.
AHL
Class I, Division 1 and 2, Groups C, D
Class II, Division 1 and 2, Groups F ➊, G
Class III

EHL
Class I, Division 1 and 2, Groups C, D

Cable Diameter
(Inches)

Description

“T”
Ratings

Catalog
Number

AHL – Explosionproof 60 - 300 W Lighting Fixtures

60-100 W, A-21 (AAU-1N)

.375 to .625

T4

AHL100

200-300 W, PS-30 (AAU-2NS)

.375 to .625

T4A

AHL200

Laminated Phenolic Handle. Wiring Connection Block takes from #16 to #14 Wire.
100 W, A-21

.406

T3A

EHL100N

EHL Replacement Globe and Guard
Heat-resistant glass globe

XP419

Aluminum guard with hook

XP163SA

Dimensions in Inches/Millimeters
AHL

EHL

6.50"/
165.1 mm

7.50"/
190.5 mm
3.31"/84.1 mm

17.63"/447.8 mm

A
C

4.88"/124.0 mm
Dia.

B

Catalog Number

A

B

C

AHL100

14.25/362.0

7.06/179.3

10.94/277.9

AHL200

15.94/404.9

8.81/223.8

12.63/320.8

➊ To reduce the risk of ignition of hazardous atmospheres, do not use where electrically conductive dusts are present (most coal dusts are not electrically
conductive).
➋ Handlamp accommodates 16-3 SO cable. Contact your sales representative if 14-3 cable is required.
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

1317

Lighting: Explosionproof — Portable

EHL – Explosionproof 100 W Portable Handlamp ➋

Lighting

CAUTION: For safe operation, weight of fixture must be supported by hanger hook, not by the flexible cord, per the National Electrical Code.

Code•Master 2™ Emergency PLT Factory Sealed Luminaires
Explosionproof, Dust-Ignitionproof

52 W, 64 W, 84 W Fluorescent. For Use with Threaded Metal Conduit.
Class I, Division 1 and 2, Groups C, D
Class II, Division 1 and 2, Groups E, F, G
Class III
NEMA 4X
Marine Type Electric Fixtures
Outside Type (Salt Water)

Suitable for use in Wet Locations
NFPA101, Life Safety Code

Applications
•	 Ideal for use in chemical and petrochemical plants, such as
manufacturers of plastics, paints and thinners; in refineries; and
in other process areas where ignitable vapors, dust, moisture
and corrosive elements may be present.
•	 Suitable for use in wet locations.

Lighting: Explosionproof — Emergency

Lighting

Features
•	 Auxiliary (emergency) lighting should be used to provide a
lighted means of egress for personnel in walkways, catwalks,
stairs, doorways, tunnels, ramps and aisles.
•	 Auxiliary (emergency) lighting should be used to provide “instant
on” illumination during power failures.
•	 Arrangement of heat-producing components results in more
efficient heat dissipation for cooler fixture operation.
•	 Safe, easy servicing without disconnecting any wiring. Patented
“wireless” design means the threading of the fixture unit onto
mounting hood makes electrical connection. This allows for the
fixture unit to easily thread off mounting hood for convenient
servicing or for immediate replacement with a “stand-by” unit.
Only wiring required is attaching two wires to connection block
in mounting hood.
•	 Connection block is easily wired: (a) loosen two screws; (b)
make wire connections; and (c) reposition connection block.
•	 Acme double-lead threads speed installation and fixture
removal from mounting hood – only half as many turns are
required as for single-lead threads. The threads do not stick or
gall, eliminating the troublesome problems often encountered
with single-lead threads during fixture unit removal.
•	 All threaded joints are flame-tight.
•	 Factory sealed. External seals not required.
•	 Fluorescent light source reduces energy costs.
•	 Fluorescent lamp life of 10,000 hours reduces relamping costs
compared to incandescent.
•	 Strategic location of lamp sockets in combination with the
interior prism design of the glass globe provides optimum light
distribution and control.
•	 Superior corrosion resistance with epoxy powder coat finish.
•	 Choice of mountings: pendant, ceiling, bracket and stanchion.
•	 Fiberglass-reinforced polyester reflectors in standard
dome, deep dome or 30° angle are ideal in installations
where luminaire is subject to exceptionally severe corrosive
atmospheres. The high bay aluminum reflector is designed for
installations where mounting height work planes range from 	
20 to 30 feet/6 to 9 meters.
•	 Optional guards protect globes from damage. Guards secure to
fixture with three screws.
•	 Fixture (52, 64 or 84 W) is available for semi-continuous
operation (one AC ballast permits two-lamp illumination when
power is on and one battery pack permits one-lamp illumination
when AC power is interrupted).
•	 Minimum operating temperature: 32 °F/0 °C.
•	 Maximum operating temperature: 104 °F/ 40 ° C

Battery Pack Information
•	 Long life, high temperature, nickel-cadmium (Ni-Cad) battery.
•	 Dual voltage (120/277 V, 60 Hz) solid state charger on open
circuit board.
•	 Five-year life expectancy.
•	 Wiring instructions for “Push-To-Test” button are supplied 	
with fixture.

1318

Illustrated Features

•	 Remote “Push-To-Test” switch is available to verify emergency
operation (order separately, see F3-82).
•	 Red indicator light is provided with each battery pack to
indicate when the battery is charging.

Standard Materials
•	 Ballast bodies, guards and pendant mounting hoods:
copperfree (4/10 of 1% max.) aluminum
•	 Ceiling, bracket and stanchion mounting hoods: sand-cast
copperfree (4/10 of 1% max.) aluminum
•	 Reflectors: aluminum or fiberglass reinforced polyester

Standard Finishes
•	 Ballast bodies, guards and mounting hoods: epoxy powder 	
coat finish, electrostatically applied for complete, uniform
corrosion protection

Options
•	 Fuse kit CF2 for field installation.

Certifications and Compliances
•	 UL Standard: UL 924, UL 844, UL 1598
•	 UL Listed: E165014

Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

Code•Master 2™ Emergency PLT Factory Sealed Luminaire Technical Data
Explosionproof, Dust-Ignitionproof

52 W, 64 W, 84 W Fluorescent. For Use with Threaded Metal Conduit.
Class I, Division 1 and 2, Groups C, D
Class II, Division 1 and 2, Groups E, F, G
Class III
NEMA 4X
Marine Type Electric Fixtures
Outside Type (Salt Water)

Suitable for use in Wet Locations
NFPA101, Life Safety Code

Classified Area Suitability of Code•Master 2 Emergency Series (Suitability includes use of reflector.)

Lamp
Type

Class I, Division 1 & 2
With Globe or with Globe & Reflector
UL/NEC Temp. Ident. No.
Nameplate
Marking
Groups

Class II, Division 1 & 2
With Globe or with Globe & Reflector
UL/NEC Temp. Ident. No.
Nameplate
Marking
Groups

Lamps
Watts

Ambient
Temp ˚
°F/°C

52

104/40

T6

C,D

T4

E,F,G

64

104/40

T6

C,D

T4

E,F,G

84

104/40

T6

C,D

T4

E,F,G

PLT

“T”
Number

350

325

T2

T2A

T2B

T2C

T2D

T3

T3A

T3B

T3C

T4

T4A

T5

Temp.
664Range 842
(°F)

619662

574617

538572

502536

448500

421446

394419

358392

331356

322329

277320

250275

214248

187212

185

Temp.
Range
(°˚C)

326350

301325

281300

261280

231260

216230

201215

181200

166180

161165

136160

121135

101120

86100

85

351450

T6

Fixture and Accessory Weights in Lbs/kg
Fixture Size

Fixture Weight

Reflector Weight

Guard Weight

52 W

45/20.4

3/1.4

2/0.9

64 W

45/20.4

3/1.4

2/0.9

84 W

45/20.4

3/1.4

2/0.9

Pendant

Ceiling

Bracket

Stanchion

2/0.9

4/1.8

6/2.7

2/0.9

Mounting Hood Weights Lbs/kg

Electrical Specification for AC Operation
Catalog
Number ➊

Fixture
Wattage

Line
Voltage (V)

Frequency
(Hz)

Type of
Ballast

Line
Amps (A)

Maximum Wattage
(W/W)

CMBFS5212

52

120

60

PLT Electronic

0.49

52

CMBFS5227

52

277

60

PLT Electronic

0.20

52

CMBFS6412

64

120

60

PLT Electronic

0.57

64

CMBFS6427

64

277

60

PLT Electronic

0.24

64

CMBFS8412

84

120

60

PLT Electronic

0.73

84

CMBFS8427

84

277

60

PLT Electronic

0.31

84

➊ For optional fusing. order kit -CF2
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

1319

Lighting: Explosionproof — Emergency

T1

Lighting

“T” Numbers Represent the Maximum Surface Temperature for Class I, Division 1 Locations and
Maximum Surface Temperature Under Dust Blanket for Class II, Division 1 Locations.

Code•Master 2™ Emergency PLT Factory Sealed Luminaires
Explosionproof, Dust-Ignitionproof

52 W, 64 W, 84 W Fluorescent. For Use with Threaded Metal Conduit.
Class I, Division 1 and 2, Groups C, D
Class II, Division 1 and 2, Groups E, F, G
Class III
NEMA 4X
Marine Type Electric Fixtures
Outside Type (Salt Water)

Suitable for use in Wet Locations
NFPA101, Life Safety Code

Lamp Watts

Lamp Type

52

PLT

Hub Size (Inches)

Catalog Number ➋➌

3/4

CFPS5275

Pendant

64

PLT

84

PLT

52

PLT

1

CFPS5210

3/4

CFPS6475

1

CFPS6410

3/4

CFPS8475

1

CFPS8410

3/4

CFCS5275

Lighting: Explosionproof — Emergency

Lighting

Ceiling
1

CFCS5210

3/4

CFCS6475

1

CFCS6410

3/4

CFCS8475

1

CFCS8410

3/4
1
3/4
1
3/4
1

CFBS5275
CFBS5210
CFBS6475
CFBS6410
CFBS8475
CFBS8410

64

PLT

84

PLT

52

PLT

64

PLT

84

PLT

52

PLT

1-1/4 or 1-1/2 ➊

CFSS52150

64

PLT

1-1/4 or 1-1/2 ➊

CFSS64150

84

PLT

1-1/4 or 1-1/2 ➊

CFSS84150

Bracket

25° Stanchion

Fixture Units
Ballast body with globe. Indicate voltage desired by adding voltage suffix to Fixture Unit catalog number listed below.
Add Voltage Suffixes
120 V
277 V

Lamp Watts

Lamp Type

Unit Catalog Number

52

PLT

CMBFS52

12

27

64

PLT

CMBFS64

12

27

84

PLT

CMBFS84

12

27

➊ 1-1/2” tapped hub furnished with 1-1/2” to 1-1/4” reducer.
➋ To order fixture with guard, add suffix -G before adding voltage suffix.
➌ Add voltage suffix -12L for 120 V with lamp; or -27L for 277 V with lamp.

1320

Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

Code•Master 2™ Emergency PLT Factory Sealed Luminaire Accessories
Explosionproof, Dust-Ignitionproof

52 W, 64 W, 84 W Fluorescent. For Use with Threaded Metal Conduit.

Mounting Hoods
Hub Size Inches

Catalog Number

Pendant
3/4

CAP-75

1

CAP-100

3/4

CAC-75

1

CAC-100

3/4

CALB-75

1

CALB-100

One Hub

Ceiling
Four hubs, 	
Three Close-Up Plugs

Four hubs, 	
Three Close-Up Plugs

One Hub

1-1/4 or 1-1/2 ➊

CAS-150

Mounting Adapter with Connection Block
Permits use of existing A-51 mounting hoods (AAC Ceiling or AALB
Bracket) with the new Code•Master 2 Fixture Unit. After removing existing
Fixture Unit and adapter, screw in the new CMAD-1 Adapter. Then thread
thenew Fixture Unit into the CMAD-1.

CMAD-1

➊ 1-1/2” tapped hub furnished with 1-1/2” to 1-1/4” reducer.
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

1321

Lighting: Explosionproof — Emergency

25° Stanchion

Lighting

Bracket

Code•Master 2™ Emergency PLT Factory Sealed Luminaire Accessories
Explosionproof, Dust-Ignitionproof

52 W, 64 W, 84 W Fluorescent. For Use with Threaded Metal Conduit.

Description

Catalog Number

Standard Dome

CMR-4ST

Deep Dome

CMR-4DD

30˚ Angle

CMR-4AN

Polyester Reflectors

Lighting

Aluminum High Bay Reflectors

CMR-4HB

Lighting: Explosionproof — Emergency

Prismatic Glass Globes

52, 64, 84 W PLT

CGL-400

52, 64, 84 W PLT

CGU4

Aluminum Guards

Connection Block — For Code•Master 2 PLT Fixtures

1322

52 W - 84 W

PLT32RS

52 W - 84 W

VPT-7

Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

Code•Master 2™ Emergency PLT Factory Sealed Luminaire Accessories
Explosionproof, Dust-Ignitionproof

52 W, 64 W, 84 W Fluorescent. For Use with Threaded Metal Conduit.

Dimensions in Inches/Millimeters
Pendant

Ceiling

Bracket
0.41"/
10.4 mm Dia.

.390"/
9.9 mm
4.58"/
116.3 mm
Dia.

4.92"/
125.0 mm Sq.

4.00"/
101.6 mm

3.91"/99.3 mm
9.86"/
250.4 mm

9.5"/
241.3 mm

2.28"/
2.46"/
62.5 mm 57.9 mm

6.10"/
154.9 mm

4.25"/
108.0 mm

3.46"/
87.9 mm
1.23"/
31.2 mm

3.92"/
99.6 mm

4.00"/
101.6 mm
5.92"/
150.4 mm

25° Stanchion

1.79"/
45.5 mm

4.5"/
60.5 mm
Dia.
2.38"/
60.5 mm Dia.

11.5"/
292.1 mm
13.75"/
349.3 mm

.94"/
23.9 mm

Lighting

9.86"/
250.4 mm

9.86"/
250.4 mm

4.00"/
101.6 mm

Pendant
A
52-84 W

B

Ceiling
C

D

A

B

Bracket
C

D

A

B

25° Stanchion
C

D

A

B

24.50/ 23.50/ 12.00/ 20.36/ 24.36/ 23.36/ 12.00/ 20.36/ 24.61/ 23.61/ 17.50/ 20.36/ 22.20/ 21.20/
622.3 596.9 304.8 517.1 618.7 593.3 304.8 517.1 625.1 599.7 444.5 517.1 563.9 538.5

C
17.50/
444.5

Reflector Dimensions in Inches/Millimeters
Type Reflector
Standard Dome
Deep Dome

A

B

C

11.20/
284.5

5.90/
149.9

18.70/
475.0

10.56/
268.2

7.00/
177.8

Standard and Deep Dome

20.30/
515.6

30° Angle

High Bay
10.96"/
278.4 mm

10.56"/
268.2 mm

13.30"/
337.8 mm

9.75”/
347.7 mm

16.16"/
410.5 mm

20.80"/
528.3 mm

Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

1323

Lighting: Explosionproof — Emergency

5.50"/
139.7 mm

Code•Master 2™ Emergency PLT Factory Sealed Luminaire Photometric Data
Explosionproof, Dust-Ignitionproof

52 W, 64 W, 84 W Fluorescent. For Use with Threaded Metal Conduit.
* Photometric data is based on a fixture
with two 32 W Compact Fluorescent PL-T
lamps (2,400 lumens each). For candlepower
values of fixtures with two 26 W PL-T lamps
(1,800 lumens each), multiply by 0.75. For
Candlepower values of fixtures with two 42 W

PL-T Lamps. (3,200 lumens each) multiply by
1.34.

Total Luminaire Efficiency = 79.8%
CIE Type - Semi-Direct
Plane

Spacing
Criteria

0-180

2.88

90-270

2.88

Diagonal

2.82

REPORT NUMBER: CMBF64G
64 W (two 32 W lamps) Fluorescent Fixture with Globe only *
Coefficients of Utilization - Zonal Cavity Method
Effective Floor Cavity Reflectance 0.20
% Ceiling Rcc

Lighting: Explosionproof — Emergency

Lighting

% Walls
Zone
0-10
10-20
20-30
30-40
40-50
50-60
60-70
70-80
80-90
90-100
100-110

Lumens
17.70
61.05
132.44
236.78
336.66
421.68
485.34
517.29
513.72
468.70
352.77

110-120

200.85

120-130

73.54

130-140
140-150
150-160
160-170
170-180

11.28
1.12
0.31
0.06
0.00

Maximum Candela = 493
Located at Horizontal Angle = 0, Vertical Angle = 70
#1 – Vertical Plane through Horizontal Angles (0-180)
(Through Max. Cd.)
#2 – Horizontal Cone through Vertical Angle (70)
(Through Max. Cd.)

CIE Type - Direct
Spacing
Criteria

0-180

1.62

90-270

1.62

Diagonal

1.74

Zone
0-30
0-40
0-60
0-90

110-120

0.00
0.00
0.00
0.00
0.00
0.00
0.00

1324

30

10

0

50

30

10

70

50

30

10

50

30

10

50

30

10

50

30

10

0

0
1
2
3
4
5
6
7
8
9
10

90
76
67
60
54
49
45
41
38
35
33

90
70
58
49
43
37
33
29
26
24
22

90
65
51
41
34
29
25
22
19
17
15

90
60
45
35
28
23
19
16
14
12
11

85
71
63
56
50
46
42
38
36
33
31

85
66
55
46
40
35
31
28
25
23
21

85
61
48
39
32
27
23
20
18
16
14

85
57
42
33
26
22
18
15
13
11
10

76
58
48
40
35
31
27
24
22
20
18

76
54
43
34
28
24
21
18
16
14
13

76
51
38
29
23
19
16
14
12
10
9

68
51
42
35
30
26
23
21
19
17
16

68
48
37
30
25
21
18
16
14
12
11

68
45
34
26
21
17
14
12
10
9
8

60
45
36
30
26
23
20
18
16
15
14

60
42
32
26
21
18
16
14
12
11
10

60
40
29
23
18
15
12
10
9
8
7

57
36
26
20
15
12
10
8
7
9
5

Lumens
211.19
447.97
1206.31
2722.64

% Lamp
4.4
9.3
25.1
56.7

% Fixture
5.5
11.7
31.5
71.1

Zone
90-120
90-130
90-150
90-180
0-180

Lumens
1022.32
1095.85
1108.26
1108.63
3831.28

% Lamp
21.3
22.8
23.1
23.1
79.8

% Fixture
26.7
28.6
28.6
28.9
100.0

Coefficients of Utilization - Zonal Cavity Method
Effective Floor Cavity Reflectance 0.20
% Ceiling Rcc

Lumens
73.25
220.57
368.60
505.61
603.19
638.42
497.24
226.17
57.98
1.64
0.00

120-130
130-140
140-150
150-160
160-170
170-180

50

70

REPORT NUMBER: CMBF64ST
64 W (two 32 W lamps) Fluorescent Fixture with Globe and
Standard Dome Reflector *

% Walls
Zone
0-10
10-20
20-30
30-40
40-50
50-60
60-70
70-80
80-90
90-100
100-110

70

Rw

Zonal Lumen Summary

Total Luminaire Efficiency = 66.5%

Plane

80

80

70

50

30

10

0

Rw

70

50

30

10

70

50

30

10

50

30

10

50

30

10

50

30

10

0

0
1
2
3
4
5
6
7
8
9
10

79
72
65
59
53
49
45
41
38
35
33

79
69
59
51
45
39
35
32
29
26
24

79
66
54
45
38
33
29
25
23
20
18

79
63
50
41
34
28
24
21
19
16
15

77
70
63
57
52
47
43
40
37
34
32

77
67
58
50
44
39
34
31
28
26
24

77
64
53
45
38
33
29
25
22
20
18

77
62
49
40
33
28
24
21
18
16
15

74
64
55
48
42
37
33
30
27
25
23

74
62
52
43
37
32
28
25
22
20
18

74
60
48
40
33
28
24
21
18
16
15

71
62
53
46
40
36
32
29
26
24
22

71
60
50
42
36
31
27
24
22
19
18

71
58
47
39
32
28
24
21
18
16
15

68
59
51
44
39
35
31
28
26
23
22

68
58
48
41
35
31
27
24
21
19
17

68
56
46
38
32
27
23
20
18
16
14

66
55
45
37
30
26
22
19
17
15
13

Zonal Lumen Summary
Maximum Candela = 808
Located at Horizontal Angle = 0, Vertical Angle = 35
#1 – Vertical Plane through Horizontal Angles (0-180)
(Through Max. Cd.)
#2 – Horizontal Cone through Vertical Angle (35)
(Through Max. Cd.)

Zone
0-30
0-40
0-60
0-90

Lumens
662.42
1168.03
2409.64
3191.04

% Lamp
13.8
24.3
50.2
66.5

% Fixture
20.7
36.6
75.5
99.9

Zone
Lumens
90-120
1.64
90-130
1.64
90-150
1.64
90-180
1.64
0-180 3192.68

% Lamp
0.0
0.0
0.0
0.0
66.5

% Fixture
0.1
0.1
0.1
0.1
100.0

Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

Code•Master 2™ Emergency PLT Factory Sealed Luminaire Photometric Data
Explosionproof, Dust-Ignitionproof

52 W, 64 W, 84 W Fluorescent. For Use with Threaded Metal Conduit.
* Photometric data is based on a fixture
with two 32 W Compact Fluorescent PL-T
lamps (2,400 lumens each). For candlepower
values of fixtures with two 26 W PL-T lamps
(1,800 lumens each), multiply by 0.75. For
Candlepower values of fixtures with two 42 W

PL-T Lamps. (3,200 lumens each) multiply by
1.34.

Total Luminaire Efficiency = 57.4%
CIE Type - Direct
Plane

Spacing
Criteria

0-180

1.52

90-270

1.70

Diagonal

1.62

REPORT NUMBER: CMBF64AN
64 W (two 32 W lamps) Fluorescent Fixture with Globe and
30° Angle Dome Reflector *
Coefficients of Utilization - Zonal Cavity Method
Effective Floor Cavity Reflectance 0.20
% Ceiling Rcc
% Walls

Lumens
62.13
187.93
317.49
428.14
471.22
454.23
384.77
276.31
157.68
13.45
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00

Maximum Candela = 731
Located at Horizontal Angle = 90, Vertical Angle = 37.5
#1 – Vertical Plane through Horizontal Angles (90-270)
(Through Max. Cd.)
#2 – Horizontal Cone through Vertical Angle (37.5)
(Through Max. Cd.)

CIE Type - Direct
Spacing
Criteria

0-180

1.44

90-270

1.44

Diagonal

1.60

Zone
0-30
0-40
0-60
0-90

110-120

0.00
0.00
0.00
0.00
0.00
0.00
0.00

0

10

70

50

30

10

50

30

10

50

30

10

50

30

10

0

0
1
2
3
4
5
6
7
8
9
10

68
61
55
50
45
41
38
35
32
30
28

68
58
49
43
37
33
30
27
24
22
20

68
55
45
37
32
28
24
21
19
17
16

68
52
41
33
28
23
20
18
16
14
12

67
59
53
48
44
40
37
34
32
29
28

67
56
48
42
37
32
29
26
24
22
20

67
54
44
37
31
27
24
21
19
17
15

67
51
40
33
27
23
20
18
15
14
12

64
54
46
40
35
31
28
25
23
21
19

64
51
43
36
31
27
23
21
19
17
15

64
49
39
32
27
23
20
17
15
14
12

61
51
44
38
34
30
27
24
22
20
19

61
49
41
35
30
26
23
20
18
16
15

61
48
39
32
27
23
20
17
15
14
12

58
49
42
37
32
29
26
24
22
20
18

58
48
40
34
29
25
22
20
18
16
15

58
46
38
31
26
22
19
17
15
13
12

57
45
36
30
25
21
18
16
14
12
11

Lumens
567.55
995.69
1921.14
2739.90

% Lamp
11.8
20.7
40.0
57.1

% Fixture
20.6
36.2
69.8
99.5

Zone
90-120
90-130
90-150
90-180
0-180

Lumens
13.45
13.45
13.45
13.45
2753.35

% Lamp
0.3
0.3
0.3
0.3
57.4

% Fixture
0.5
0.5
0.5
0.5
100.0

Coefficients of Utilization - Zonal Cavity Method
Effective Floor Cavity Reflectance 0.20
% Ceiling Rcc

Lumens
88.95
260.61
413.34
539.82
630.36
641.74
436.60
164.84
47.37
1.92
0.00

120-130
130-140
140-150
150-160
160-170
170-180

10

30

REPORT NUMBER: CMBF64DD
64 W (two 32 W lamps) Fluorescent Fixture with Globe and
Deep Dome Reflector *

% Walls
Zone
0-10
10-20
20-30
30-40
40-50
50-60
60-70
70-80
80-90
90-100
100-110

30

50

Zonal Lumen Summary

Total Luminaire Efficiency = 67.2%

Plane

50

70

80

70

50

30

10

0

Rw

70

50

30

10

70

50

30

10

50

30

10

50

30

10

50

30

10

0

0
1
2
3
4
5
6
7
8
9
10

80
73
66
60
55
50
46
43
40
37
34

80
70
61
53
47
41
37
33
30
28
25

80
67
56
47
41
35
31
27
24
22
20

80
65
52
43
36
31
26
23
20
18
16

78
71
65
59
53
49
45
41
38
36
34

78
68
59
52
46
41
36
33
30
27
25

78
66
55
47
40
35
30
27
24
22
20

78
63
52
43
36
30
26
23
20
18
16

75
66
57
50
44
39
35
32
29
26
24

75
63
53
45
39
34
30
27
24
21
19

75
61
50
42
35
30
26
23
20
18
16

71
63
55
48
42
38
34
31
28
26
24

71
61
52
44
38
33
29
26
23
21
19

71
60
49
41
35
30
26
23
20
18
16

69
60
53
46
41
37
33
30
27
25
23

69
59
50
43
37
33
29
26
23
21
19

69
58
48
40
34
29
25
22
20
18
16

67
56
47
39
33
28
24
21
19
16
15

Zonal Lumen Summary
Maximum Candela = 933
Located at Horizontal Angle = 0, Vertical Angle = 7.5
#1 – Vertical Plane through Horizontal Angles (0-180)
(Through Max. Cd.)
#2 – Horizontal Cone through Vertical Angle (7.5)
(Through Max. Cd.)

Zone
0-30
0-40
0-60
0-90

Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

Lumens
762.91
1302.73
2574.82
3223.63

% Lamp
15.9
27.1
53.6
67.2

% Fixture
23.7
40.4
79.8
99.9

Zone
90-120
90-130
90-150
90-180
0-180

Lumens
1.92
1.92
1.92
1.92
3225.55

% Lamp
0.0
0.0
0.0
0.0
57.4

% Fixture
0.1
0.1
0.1
0.1
100.0

1325

Lighting: Explosionproof — Emergency

110-120
120-130
130-140
140-150
150-160
160-170
170-180

70

Rw

Lighting

Zone
0-10
10-20
20-30
30-40
40-50
50-60
60-70
70-80
80-90
90-100
100-110

80

Code•Master 2™ Emergency PLT Factory Sealed Luminaire Photometric Data
Explosionproof, Dust-Ignitionproof

52 W, 64 W, 84 W Fluorescent. For Use with Threaded Metal Conduit.
* Photometric data is based on a fixture
with two 32 W Compact Fluorescent PL-T
lamps (2,400 lumens each). For candlepower
values of fixtures with two 26 W PL-T lamps
(1,800 lumens each), multiply by 0.75. For
Candlepower values of fixtures with two 42 W

PL-T Lamps. (3,200 lumens each) multiply by
1.34.

Total Luminaire Efficiency = 58.9%

REPORT NUMBER: CMBF64HB
64 W (two 32 W lamps) Fluorescent Fixture with Globe and High Bay Reflector *

CIE Type - Direct
Plane

Spacing
Criteria

0-180

0.82

Coefficients of Utilization - Zonal Cavity Method

90-270

0.82

Effective Floor Cavity Reflectance 0.20

Diagonal

0.92

Zone

Lumens

% Ceiling Rcc

Lighting: Explosionproof — Emergency

Lighting

% Walls

Rw

80
70

50

70
30

10

70

50

50
30

10

50

30

30
10

50

30

10
10

50

30

0
10

0

0 70 70 70 70 68 68 68 68 65 65 65 63 63 63 60 60 60 59

0-10

239.15

1 66 64 63 61 65 63 62 60 61 59 58 58 57 57 56 56 55 54

10-20

599.67

2 62 59 56 54 61 58 55 53 56 54 52 54 52 51 52 51 50 49

20-30

645.20

3 58 54 51 48 57 53 50 47 51 49 47 50 48 46 49 47 45 44

30-40

625.54

4 55 50 46 43 54 49 45 43 48 44 42 46 44 42 45 43 41 40

40-50

452.95

5 51 46 42 39 50 45 41 39 44 41 38 43 40 38 42 39 37 36

50-60

185.71

6 48 42 38 35 47 42 38 35 41 37 35 40 37 35 39 36 34 33

60-70

58.40

7 46 39 35 32 45 39 35 32 38 35 32 37 34 32 37 34 32 31

70-80

15.26

8 43 37 33 30 42 36 32 30 36 32 30 35 32 29 34 31 29 28

80-90

4.25

9 41 34 30 28 40 34 30 28 33 30 27 33 30 27 32 29 27 26

90-100

0.69

10 38 32 28 26 38 32 28 26 31 28 26 31 28 25 30 27 25 25

100-110

0.00

110-120

0.00

120-130

0.00

Zonal Lumen Summary
Zone

Lumens

% Lamp

% Fixture

Zone

Lumens

% Lamp

% Fixture

130-140

0.00

0-30

1484.03

30.9

52.5

90-120

0.69

0.0

0.0

140-150

0.00

0-40

2109.57

43.9

74.6

90-130

0.69

0.0

0.0

150-160

0.00

160-170

0.00

170-180

0.00

1326

Maximum Candela = 2540
Located at Horizontal Angle = 0, Vertical Angle = 5
#1 – Vertical Plane through Horizontal Angles (0-180)
(Through Max. Cd.)
#2 – Horizontal Cone through Vertical Angle (5)
(Through Max. Cd.)

0-60

2748.23

57.3

97.2

90-150

0.69

0.0

0.0

0-90

2826.12

58.9

100.0

90-180

0.69

0.0

0.0

2628.80

58.9

100.0

0-180

Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

ELS Series Emergency Lighting System
Explosionproof, Dust-Ignitionproof

Remote and direct mounted fixtures for hazardous location applications
Class I, Division 1 and 2, Groups B*, C, D
Class II, Division 1 and 2, Groups E, F, G
Class III

Applications
•	 ELS Series features an emergency lighting power unit that is
designed to provide safe operation in the presence of hazardous
gases, vapors or dusts, defined by the National Electrical Code
as Class I, Groups C and D, and Class II, Groups E, F and G.
•	 Typical applications include all means of egress (such as
walkways, exit ramps, stairs and aisles) for hazardous areas
which include oil refineries, petrochemical facilities, pulp and
paper mills, chemical storage areas, wastewater treatment
facilities and grain elevators.

Features

Lighting

Lighting: Explosionproof — Emergency

•	 The electronics consist of a solid-state charger, transfer circuit
and low-voltage battery disconnect circuit.
•	 The unit test switch and AC “On” indicator light are housed in
a separate module that may be attached directly to the unit
housing or mounted remotely for ease of testing.
•	 All ELS Series units are rated for operation in NEC Class I,
Division 1 and 2, Groups C and D; and Class II, Division 1 and 2,
Groups E, F, and G environments.
•	 Housing provisions allow for the attachment of two optional
explosionproof lighting fixtures.
•	 Unit capacity is sufficient for the connection of up to four 6- or
12- volt, 18-watt fixtures.
•	 Units provide 90 minutes of emergency operation.
•	 The solid-state charger maintains battery at full charge.
•	 Upon failure of utility voltage, the DC emergency lighting load is
connected to the battery.
•	 During emergency operation, automatic battery protection from
deep discharge damage is provided by a low-voltage battery
disconnect (LVD) circuit.
•	 Upon restoration of normal power, the charger will begin a
recharge cycle. It will bring the battery to full capacity within
acceptable UL time standards.
•	 A pilot light indicates the presence of AC line voltage, and a test
switch is provided for checking transfer operation. Lock-out
type guard on push button accepts locks with up to 1/4”/6.5
mm hasp.
•	 A universal transformer allows operation on 120 or 277 Vac
lines.
•	 Emergency power source is a maintenance-free, sealed, 	
pure-lead battery suited for harsh temperature environments 	
for 32 °F to 104 °F/0 °C to 40 °C.
	 — Never necessary to add water.
	 — Expected life is 10 years
	 — Compact in design
•	 Standard illumination is provided during power failure only using
fixtures specially designed for emergency lighting in hazardous
environments, supplied with double contact bayonet base 18or 28-watt incandescent lamps.
•	 Designed for easy installation. Provided with 4 mounting holes
for attachment to a wall or other suitable surface. Mounting
hardware not included.
•	 Housing is drilled and tapped for installation of utility 	
1/2”/12.7 mm NPT conduit.
•	 Quick access to internal wiring and components is provided 	
by thread-on cover.
•	 All necessary fittings for test switch/ pilot light module 	
supplied standard.

Standard Materials
•	 Battery enclosure, fixtures, guards and pendant mount:
copperfree (4/10 of 1% max.) aluminum.
•	 Ceiling and bracket mounts: malleable iron with aluminum
adapter
•	 Reflectors: porcelain enameled steel
•	 Test Switch: copperfree (4/10 of 1% max.) aluminum with
stainless steel hardware

Standard Finishes
•	 Enclosure, fixtures and test station: epoxy powder coat 	
finish electrostatically applied for complete and uniform 	
surface protection
•	 Reflectors: white porcelain enamel

Options
•	 The fixture may be adapted to serve as an exit sign through use
of an Auxiliary Exit Housing.
•	 Time Delay Relay (15 minutes) available to permit normal
lighting to re-establish brightness. Add suffix -T1 for 120 Vac, or
-T2 for 277 Vac.

Certifications and Compliances
•	 UL Standard: UL 924, UL 844, UL 1598
•	 UL Listed: 175025

* Contact your sales representative for Class I, Group B rating.
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

1327

ELS Series Emergency Lighting System Technical Data
Explosionproof, Dust-Ignitionproof

Remote and direct mounted fixtures for hazardous location applications
Class I, Division 1 and 2, Groups B*, C, D
Class II, Division 1 and 2, Groups E, F, G
Class III

Order using catalog numbering guide below or select catalog number from tables on following pages.
Catalog Numbering Guide
ELS

2

18

Series:

6

T1G

Wattage per lamp
18 – 18 W
28 – 28 W

Options
T1 – Time delay relay, 120
Vac input
T2 – Time delay relay, 277
Vac input
G – Guard installed on
fixture

Lighting

Number of direct mounted fixtures
0 – no direct mounted fixtures
1 – 1 direct mounted fixture
2 – 2 direct mounted fixtures

Lamp Voltage
6 – 6 Vdc
12 – 12 Vdc

Lighting: Explosionproof — Emergency

Capacity of standard ELS unit (75 W for 90 minutes)
Up to 2 fixtures may be direct mounted. The remainder must be remote mounted.
Combination
Number

Number of
Fixtures

Wattage per
Fixture

Total
Wattage

1

1

18

18

2

1

28

28

3

2

18

36

4

2

28

56

5

3

18

54

6

1

28

64

6

2

18

64

7

4

18

72

Lamp
Watts

Supply Wire Temp
°F/°C

Ambient Temp
°F/°C

Class I, Division 1 & 2
Operating Temperature

Class II, Division 1 & 2 (Groups E, F & G)
Operating Temperature

18

257/125

104/40

T5

T3C

28

257/125

104/40

T5

T3C

“T” Numbers Represent the Maximum Surface Temperature for Class I, Division 1 Locations and
Maximum Surface Temperature Under Dust Blanket for Class II, Division 1 Locations.

NOTE: The maximum operating temperature of the fixture must not exceed the ignition temperature of the gas, vapor or dust to be encountered per the National
Electrical Code. Operating temperatures are with and without reflectors and guards.

“T”
Number

T1

350

325

T2

T2A

T2B

T2C

T2D

T3

T3A

T3B

T3C

T4

T4A

T5

T6

Temp
Range
(°F)

664842

619662

574617

538572

502536

448500

421446

394419

358392

331356

322329

277320

250275

214248

187212

185

Temp.
Range
(°C)

351450

326350

301325

281300

261280

231260

216230

201215

181200

166180

161165

136160

121135

101120

86100

85

* Contact your sales representative for Class I, Group B rating.

1328

Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

ELS Series Emergency Lighting System
Explosionproof, Dust-Ignitionproof

Remote and direct mounted fixtures for hazardous location applications
Class I, Division 1 and 2, Groups C, D
Class II, Division 1 and 2, Groups E, F, G
Class III

Emergency Lighting System with Direct Mounted Fixtures
Catalog Number
(Lamp(s) Included)

Watts per Lamp

Lamp Voltage

Input Voltage

2

18

6 Vdc

120/277 Vac

ELS2186 ➊➋➌➍

2

28

6 Vdc

120/277 Vac

ELS2286 ➊➋➌➍

2

18

12 Vdc

120/277 Vac

ELS21812 ➊➋➌➍

2

28

12 Vdc

120/277 Vac

ELS22812 ➊➋➌➍

1

18

6 Vdc

120/277 Vac

ELS1186 ➋➌➍

1

28

6 Vdc

120/277 Vac

ELS1286 ➊➋➌➍

1

18

12 Vdc

120/277 Vac

ELS11812 ➊➋➌➍

1

28

12 Vdc

120/277 Vac

ELS12812 ➊➋➌➍

Lamp Voltage

Input Voltage

Catalog Number
with Push-to-Test
(Incl. Fittings)

6 Vdc

120/277 Vac

ELS06 ➊➋➌

12 Vdc

120/277 Vac

ELS012 ➊➋➌

Lighting

Number of Fixtures

Emergency Lighting System Enclosure with Battery and Charger

Watts Per
Lamp

Lamp
Voltage

Catalog Number
(Lamp Included)

18

6 Vdc

AP1050-186-DM ➍

28

6 Vdc

AP1050-286-DM ➍

18

12 Vdc

AP1050-1812-DM ➍

28

12 Vdc

AP1050-2812-DM ➍

➊ 1/2” NPT provided for AC input.
➋ Add suffix T1 for time delay relay for 120 Vac input.
➌ Add suffix T2 for time delay relay for 277 Vac input.
➍ To order fixtures with guard installed add suffix G. Reflectors and exit signs are ordered separately. See Accessories page.

Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

1329

Lighting: Explosionproof — Emergency

Emergency Lighting System Fixture for Direct Mounting to Enclosure Includes all necessary fittings and lamp.

ELS Series Emergency Lighting System
Explosionproof, Dust-Ignitionproof

Remote and direct mounted fixtures for hazardous location applications
Class I, Division 1 and 2, Groups C, D
Class II, Division 1 and 2, Groups E, F, G
Class III

Emergency Lighting System Fixture for Remote Mounting — Lamp Included — Shown with Optional Guard
Mounting
Type

Watts Per
Lamp

Lamp
Voltage

Catalog Number
(Lamp Included) ➊

18

6 Vdc

AP1050-186

28

6 Vdc

AP1050-286

18

12 Vdc

AP1050-1812

28

12 Vdc

AP1050-2812

18

6 Vdc

AC1050-186

28

6 Vdc

AC1050-286

18

12 Vdc

AC1050-1812

28

12 Vdc

AC1050-2812

18

6 Vdc

ALB1050-186

28

6 Vdc

ALB1050-286

18

12 Vdc

ALB1050-1812

28

12 Vdc

ALB1050-2812

18

6 Vdc

ASB1050-186

28

6 Vdc

ASB1050-286

18

12 Vdc

ASB1050-1812

28

12 Vdc

ASB1050-2812

Pendant — One 1/2” Hub

Lighting: Explosionproof — Emergency

Lighting

Ceiling — Four 1/2” Hubs, Three Close-Up Plugs

Long Bracket — Four 1/2” Hubs, Three Close-Up Plugs

Short Bracket — 15 degrees — Two 1/2” Hubs, One Close-Up Plug

Emergency Lighting System Replacement Fixtures — Lamp included — Fits existing mounting hood
Watts Per
Lamp

Lamp
Voltage

Catalog Number
(Lamp Included) ➊

18

6 Vdc

AAU1N-186

28

6 Vdc

AAU1N-286

18

12 Vdc

AAU1N-1812

28

12 Vdc

AAU1N-2812

➊ To order fixtures with guard installed, add suffix G. Reflectors and exit signs are ordered separately. See Accessories page.

1330

Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

ELS Series Emergency Lighting System Accessories
Explosionproof, Dust-Ignitionproof

Remote and direct mounted fixtures for hazardous location applications

Description

Catalog Number

Guard

AAGU1

Three-Way Exit Sign

CJEXRN

Epoxy enameled steel — 6”-high red lettering
Mounts to fixture units in place of guard.

AEXR-15R

Lighting

Epoxy enameled steel — 6”-high red lettering
Mounts to fixture units in place of guard.
Single-Sided Exit Sign

Lighting: Explosionproof — Emergency

30° Angle Reflector

AARW15AN

Standard Dome Reflector

AARW15ST

Push-to-Test Station
Complete Push-to-Test Station

EFDCB150J1U1-T-A

Cover with Switch and Pilot Light

EFKB-J1U1-TEST

Switch Only

SPBB-U1-Q

Pilot Light Only

SPLNS-RE-B

Lamp, 18 W, 6 Vdc

59620527074

Lamp, 28 W, 6 Vdc

59620527075

Lamp, 18 W, 12 Vdc

59620527076

Lamp, 28 W, 12 Vdc

59620527078

Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

1331

ELS Series Emergency Lighting System Weights and Dimensions
Explosionproof, Dust-Ignitionproof

Remote and direct mounted fixtures for hazardous location applications

Weight lbs/kg

Catalog Number

Weight lbs/kgs

Catalog Number

52.0/23.6
11.0/5.0
9.0/4.1
12.5/5.7
16.6/7.5
12.5/5.7
4.0/1.8

ELS06, ELS012
AP1050-186-DM
AP1050-186
AC1050-186
ALB1050-186
ASB1050-186
EFDCB150J1U1-T-A

7.6/3.4
0.4/0.2
5.0/2.3
5.0/2.3
2.1/1.0
2.1/1.0

AAU1N-186
AAGU1
AEXR-15R
CJEXRN
AARW15AN
AARW15ST

Dimensions in Inches/Millimeters

Lighting

14.69"/
373.1 mm

13.50"/342.9 mm

14.38"/365.3 mm

11.63"/
295.4 mm

10.75"/
273.1 mm

12.00"/
304.8 mm

14.12"/
358.6 mm

12.25"/
311.2 mm

12.25"/
311.2 mm

Lighting: Explosionproof — Emergency

13.13"/333.5 mm

7.06"/
179.3 mm

Battery Enclosure

Direct Mount fixture

4.75"/120.7 mm
5.38"/
136.7 mm

Pendant Mount
2.63"/66.8 mm

2.69"/68.3 mm
13.13"/
333.5 mm

12.94"/
328.7 mm

.38"/9.7 mm

3.38"/
85.9 mm

.38"/9.7 mm
1.31"/
33.8 mm

45°

13.56"/
344.4 mm

13.75"/
349.3 mm

13.13"/
333.5 mm
13.75"/
349.3 mm

9.13"/
231.9 mm

12.38"/
314.5 mm
7.06"/
179.3 mm

Ceiling Mount

Long Bracket Mount

Short Bracket Mount

3.00"/
76.2 mm
6.88"/
174.8 mm
5.41"/
137.4 mm

11.75"/298.5 mm

"/
.00 m
104.0 m
25

8.50"/
215.9 mm

EFDCB150J1JU1-T-A

AEXR-15R

33.50"/850.9 mm

7.63"/
193.8 mm

AARW15AN

13.00"/330.2 mm

9.25"/
235.0 mm
4.38"/
111.3 mm
28.67"/
728.2 mm

ELS with 2 direct mounted fixtures

1332

12.00"/
304.8 mm

CJEXRN

14.00"/355.6 mm

AARW15ST

Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

HBE Series Round Bulkhead Luminaires

Increased Safety
Zone 1 & 2 - 21 & 22
II 2 GD
ATEX / IEC
IP65

Applications
•	
	
	
	

Suitable for use in:
— Stairways
— Small areas
— Emergency exit

Features
•	 For incandescent lamps 60 W to 150 W maximum, mixed lamp
100 W maximum. Lamps not supplied.
•	 E27 lampholder.
•	 Screw locking mechanism.
•	 Operates in all positions.
•	 Connection to lampholder via two 0.003 x 0.004 in2 /
2 x 2.5 mm2 terminals.
•	 Internal earth two terminals 0.003 x 0.004 in2 / 2 x 2.5 mm2.
External earth 0.002 x 0.006 in2 / 1 x 4 mm2.
•	 Three M20 entries in “T” formation. Supplied with one M20
cable gland (dia. 0.26 to 0.57 in / 6.5 to 14.5 mm) and two M20
blanking plugs.

Standard Materials
•	
•	
•	
•	
•	

HBERI15 and HBEPGZ

Body: gray painted aluminum alloy
Diffuser: glass
Sealing gasket: silicone
Guard: zinc plated steel
Cable gland and blanking plug: polyamide

Certifications and Compliances
Certification Type HBe150
Gas, Zones 1 and 2
— Conforming to ATEX 94/9/CE: CE 0081 II 2 G
— ATEX/IEC Protection: Ex e II
— T Rating: See Table
Dust, Zones 21 and 22
— Conforming to ATEX 94/9/CE: CE 0081 II2 D
— ATEX/IEC Protection: Ex tD A21
— Surface Temperature: T216 °F/T102 °C to T279 °F/T137 °C
Ambient Temperature: -40 °F/-40 °C to 122 °F/+50 °C
CE Declaration of Conformity: 50244
ATEX Certificate: LCIE 02 ATEX 6228X
IEC Certificate: LCIE Ex 02.023X
Index of Protection (solid & liquid): IP65
Ex Standards: EN / IEC 60079-0; 60079-7; 61241-0; 61241-1
Product Standards: EN / IEC 60598-1
Other Standards: EN / IEC 60529 (IP)

Lighting: Increased Safety/Flameproof — Bulkhead

Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

Lighting

•	
•	
	
	
	
•	
	
	
	
•	
•	
•	
•	
•	
•	
•	
•	

1333

HBE Series Round Bulkhead Luminaires

Increased Safety
Zone 1 & 2 - 21 & 22
II 2 GD
ATEX / IEC
IP65

Weight
(lbs/kg)

Volume
(in3/dm3)

Pack

Catalog Number

6.61/3

915.36/15

1

HBERI15

Pack

Catalog Number

Protective Guard

1

HBEPGZ

Spare lampglass

1

HBEGD

Accessories

T-Rating for Dust and Gas
Power and Type

Watts

Type

Dust
Operating
Positions

Surface T° for
Ta = 122° F/50° C

Gas
For Ta = 104° F/40° C
T° at
T Rating
Cable Entry

Lighting

Any Position
60

Incandescent

216°F/102°C

Any Position

Lighting: Increased Safety/Flameproof — Bulkhead

75

Incandescent

225°F/107°C

Any Position
100

Mercury

243°F/117°C

Any Position
100

Incandescent

279°F/137°C

Any Position
150

Mixed

266°F/130°C

122° F/50° C
T Rating

T° at
Cable Entry

T2



T2



T3



T3



T4



T4



T2



T2



T3



T3



T4



T4



T2



T2

181°F/83°C

T3



T3

181°F/83°C

T3



T3



T1

194°F/90°C

T1

212°F/100°C

T3

194°F/90°C

T2

212°F/100°C

T3



T3



T2

180°F/82°C

T2

92°C

T3

180°F/82°C

T3

92°C

T3



T3



 Not Applicable, no need for high temperature cable for cable entry temperature less than +176 ºF/+80 ºC

1334

Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

HBE Series Round Bulkhead Luminaires

Increased Safety

Dimensions in Inches/Millimeters
6.81"/
173 mm
6.14"/
156 mm

Cable entries

11.65"/
296 mm

Ø0.23"/
6 mm

6.30"/
160 mm

Protective guard

Photometric Data ➊

Lighting

150 W Incandescent
NF C 71-120: .062 J + 0.10 T
Candela
Distribution
Degrees

0

94

5

95
97

15

104

20

104

30

105

40

86

50

85

60

77

70

113

80

115

90

108

100

32

90°
80°
70°

Lighting: Increased Safety/Flameproof — Bulkhead

10

100°

60°
50°
40°

30°
0°	

15°	

20°

➊ Polar curves for a 1000 lm flux, according to NF C 71-120 Luminaire symbol according to NF C 71-121.
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

1335

HBD Series Bulkhead Luminaires

Flameproof

Zone 1, 2, 21 & 22
II 2 GD
ATEX / IEC
IP66 - IK08

Applications
•	
	
	
	

Suitable for use in:
— Stairways
— Small areas
— Emergency exit

Lighting

Features
•	 HBDR
— Lamps (not supplied)
— Incandescent 200 W maximum
— Compact Fluorescent 23 W maximum
— Mixed 160 W maximum
— Threaded flameproof joint.
— Operates on ceiling and wall.
•	 HBRO
— Incandescent 60 W to 100 W maximum
— Compact fl uorescent 15 W maximum
— Operates in any position.
— For incandescent 60 W & 100 W a high temperature cable
223 °F/106 °C is required.
•	 Lamps are not supplied.
•	 E27 lampholder.
•	 Fixing by two integrated brackets.
•	 Connection to lampholder via two terminals 0.004 in2 / 2.5 mm2.
•	 Internal earth two terminals 0.004 in2 / 2.5 mm2.
•	 External earth one 0.006 in2 / 4 mm2.
•	 3 x M20 threaded entries in “T” formation.
•	 Supplied with two blanking plugs M20.

HBDR
Round Bulkhead

Standard Materials
•	 Body and bezel: gray painted aluminum
•	 Glass: sealed toughened lamp glass
•	 Protective guard: zinc plated steel

Lighting: Increased Safety/Flameproof — Bulkhead

Certifications and Compliances
•	 HBRD
— Certification Type HBRd
— Gas, Zones 1 and 2
	 – Conforming to ATEX 94/9/CE: CE 0081
II 2 G
	 – ATEX/IEC Protection: Ex d IIC
	 – T Rating: See Table
— Dust, Zones 21 and 22
	 – Conforming to ATEX 94/9/CE: CE 0081
II 2 D
	 – ATEX/IEC Protection: Ex tD A21
— Ambient Temperature:  -40 °F/-40 °C to 131 °F/55 °C
— CE Declaration of Conformity: 50242
— ATEX Certificate: LCIE 02 ATEX 6163
— IEC Certificate: LCIE Ex 02.014
•	 HBRO
— Certification Type HBOd
— Gas, Zones 1 and 2
	 – Conforming to ATEX 94/9/CE: CE 0081
II 2 G
	 – ATEX/IEC Protection: Ex d IIB
	 – T Rating: See Table
— Dust, Zones 21 and 22
	 – Conforming to ATEX 94/9/CE: CE 0081
II 2 D
	 – ATEX/IEC Protection: Ex tD A21
— Ambient Temperature:  -4 °F/-20 °C to 104 °F/40 °C
— CE Declaration of Conformity: 50232
— ATEX Certificate: LCIE 02 ATEX 6162
— IEC Certificate: LCIE Ex 02.013

1336

HBDO
Oval Bulkhead

•	
•	
•	
•	
•	
•	
•	

Other Certifications: GOST
Index of Protection (solid & liquid): IP66
Impact Resistance (shock): IK08
Internal Volume: > 122.05 in3/ 2 dm3 (2 liters)
Ex Standards: EN / IEC 60079-0; 60079-1; 61241-0; 61241-1
Product Standards: EN / IEC 60598-1
Other Standards: EN / IEC 60529 (IP); 62262 (IK)

Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

HBDR Series Bulkhead Luminaires

Flameproof

Zone 1, 2, 21 & 22
II 2 GD
ATEX / IEC
IP66 - IK08

Weight
(lbs/kg)

Volume
(in3/dm3)

Pack

Catalog Number

16.53/7.5

51.59/23.4

1

HBDR

Pack

Catalog Number

1

HBDRPGZ

Accessories
Protective Guard

T-Rating for Gas
Operating Positions
Power and Type
Watts
8
15

Type
Compact Fluorescent
Compact Fluorescent

Ambient
Temperature
T Rating
T Rating

Ceiling

Wall

104° F/40° C
T6
T6

122° F/50° C
T6
T6

131°F/55°C
T6
T6

104° F/40° C
T6
T6

122° F/50° C
T6
T6

131°F/55°C
T6
T6

T Rating

T6

T6

T6

T5

T5

T4

Incandescent

200

Incandescent

T Rating
T Rating

T5
T4

T4
T4

T4
T4

T5
T4

T4
T4

T4
T4

100

Mixed

180

Mixed

T° at cable entry

—

183° F/84° C 192° F/89° C

—

183° F/84° C 192° F/89° C

T Rating
T Rating
T° at cable entry

T4
T3
—

T4
T4
T3
T3
188° F/87 C 198° F/92° C

T4
T3
—

T4
T4
T3
T3
189° F/87° C 198° F/92° C

Surface Temperature for Dust
Operating Positions
Power and Type

Ceiling

Wall

Watts
8
15
23
100

Type
Compact Fluorescent
Compact Fluorescent
Compact Fluorescent
Incandescent

Surface T°
for Ta = 131°F/55°C
140° F/60° C
147° F/64° C
156° F/69° C
221° F/105° C

T° at Cable Entry
Ta= 131°F/55°C
–
–
–
–

Surface T°
for Ta = 131°F/55°C
158° F/70° C
169° F/76° C
205° F/96° C
221° F/105° C

T° at Cable Entry
Ta= 131°F/55°C
–
–
–
–

200

Incandescent

266° F/130° C

192° F/89° C

266° F/130° C

192° F/89° C

100
160

Mixed
Mixed

266° F/130° C
300° F/149° C

–
198° F/92° C

266° F/130° C
300° F/149° C

–
198° F/92° C

No need for high temperature cable for cable entry temperature less than 176° F/80° C.
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

1337

Lighting: Increased Safety/Flameproof — Bulkhead

Compact Fluorescent

Lighting

23
100

HBDO Series Bulkhead Luminaires

Flameproof

Zone 1, 2, 21 & 22
II 2 GD
ATEX / IEC
IP66 - IK08

Weight
(lbs/kg)

Volume
(in3/dm3)

Pack

Catalog Number

6.61/3

19.84/9

1

HBDO

Pack

Catalog Number

1

HBDOPGZ

Accessories

Protective Guard
Terminal block for through wiring 0.003 x 0.004 in / 2 x 2.5 mm with high
temperature sleeve
2

2

094784

T-Rating for Gas

Lighting: Increased Safety/Flameproof — Bulkhead

Lighting

Power and Type
Watts

Type

Temperature class for Ta = 104° F/40° C

T° at Cable Input for Ta = 104° F/40° C

7

Compact Fluorescent

T6

—

11

Compact Fluorescent

T6

—

15

Compact Fluorescent

T6

—

60

Incandescent

T4

223° F/106°C

100

Incandescent

T4

223° F/106°C

Watts

Type

Temperature class for Ta = 104° F/40° C

T° at Cable Input for Ta = 104° F/40° C

7

Compact Fluorescent

169° F/76° C

—

11

Compact Fluorescent

169° F/76° C

—

15

Compact Fluorescent

169° F/76° C

—

60

Incandescent

246° F/119° C

223° F/106° C

100

Incandescent

246° F/119° C

223° F/106° C

T-Rating for Dust
Power and Type

No need for high temperature cable for cable entry temperature less than +176 °C/+80 °C.

1338

Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

HBDR Series Bulkhead Luminaire Dimensions and Photometric Data

Flameproof

Dimensions in Inches/Millimeters
7.56"/
192 mm

12.99"/
330 mm

(with guard)

6.10"/
155 mm

Ø0.43"/
11 mm

0.51"/
13 mm
6.69"/
170 mm

12.08"/
307 mm

(without guard)

Photometric Data ➊
Lighting

Incandescent
NF C 71-120: .068 G + 0.01 T
Candela
Distribution
0

185

5

178

10

171

15

156

20

132

25

110

30

97

35

87

40

90

45

100

50

96

60

58

70

58

100°
90°
80°
70°

Lighting: Increased Safety/Flameproof — Bulkhead

Degrees

60°
50°
40°

30°
0°	

10°	

20°

➊ Polar curves for a 1000 lm output according to NF C 71-120 Luminaire symbol according to NF C 71-121.
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

1339

HBDO Series Bulkhead Luminaire Dimensions and Photometric Data

Flameproof

Dimensions in Inches/Millimeters
7.09"/
180 mm

8.66"/
220 mm

4.80"/
122 mm

0.18"/
4.5 mm

6.30"/
160 mm

Photometric Data ➊

Incandescent
NF C 71-120: .068 H

Lighting

Candela
Distribution
67

100°

5

94

10

96

15

99

90°
80°
70°

20

99

60°

25

97

50°

30

95

35

96

40

91

45

91

50

98

60

87

70

69

Lighting: Increased Safety/Flameproof — Bulkhead

Degrees
0

40°

30°

0°	

10°	

20°

➊ Polar curves for a 1000 lm output according to NF C 71-120 Luminaire symbol according to NF C 71-121.

1340

Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

HBN Series Round Bulkhead Luminaires

Flameproof
Zone 2 and 22
II 3 GD
ATEX / IEC
IP65

Applications
•	
	
	
	

Suitable for use in:
— Stairways
— Small areas
— Emergency exit

Features
•	 For incandescent lamps 60 W to 150 W maximum, mixed lamp
100 W maximum, mercury 80 W maximum (remote mercury
ballast not supplied). Lamps not supplied.
•	 E27 lampholder.
•	 Screw locking mechanism.
•	 Operates in all positions.
•	 Connection to lampholder via two 0.003 x 0.004 in2 /
2 x 2.5 mm2 terminals.
•	 Internal earth two terminals 0.003 x 0.004 in2 / 2 x 2.5 mm2.
External earth 0.002 x 0.006 in2 / 1 x 4 mm2.
•	 Three M20 entries in “T” formation. Supplied with one M20
cable gland (dia. 0.26 to 0.57 in / 6.5 to 14.5 mm) and two M20
blanking plugs.

Standard Materials
•	
•	
•	
•	
•	

HBNRI15 and HBEPGZ

Body: gray painted aluminum alloy
Diffuser: glass
Sealing gasket: silicone
Guard: zinc plated steel
Cable gland and blanking plug: polyamide
Certification Type HBn150
Gas, Zone 2
— Conforming to ATEX 94/9/CE: CE
II 3 G
— ATEX/IEC Protection: Ex nR II
— T Rating: See Table 1
Dust, Zone 22
— Conforming to ATEX 94/9/CE: CE
II 3 D
— ATEX/IEC Protection: Ex tD A22
— Surface Temperature: See Table 1
Ambient Temperature: -4 °F/-20°C Ta 122°F/50°C
-4 °F/-20°C Ta 104 °F/40°C (80 W mercury)
CE Declaration of Conformity: 50220
ATEX Certificate: LCIE 03 ATEX 6167X
IEC Certificate: LCIE Ex 03.026X
Index of Protection (solid & liquid): IP65
Ex Standards: EN / IEC 60079-0; 60079-15; 61241-0; 61241-1
Product Standards: EN / IEC 60598-1
EMC Standards: EN / IEC 55015; 61547
Other Standards: EN / IEC 60529 (IP)

Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

Lighting: Increased Safety/Flameproof — Bulkhead

•	
•	
	
	
	
•	
	
	
	
•	
	
•	
•	
•	
•	
•	
•	
•	
•	

Lighting

Certifications and Compliances

1341

HBN Series Round Bulkhead Luminaires

Flameproof
Zone 2 and 22
II 3 GD
ATEX / IEC
IP65

Weight
(lbs/kg)

Volume
(in3/dm3)

Pack

Catalog Number

6.61/3

33.07/15

1

HBNRI15

Pack

Catalog Number

1

HBEPGZ

Accessories

Protective Guard

HBEGD

Spare Lampglass

T-Rating for Dust and Gas

Lighting: Increased Safety/Flameproof — Bulkhead

Lighting

Power and Type

Dust

Gas

Watts

Type

Surface T° for
Ta = 122 °F/+50 °C

T Rating for
Ta = 104 °F/+40 °C

T Rating for
Ta = 122 °F/+50 °C

T° at Cable Input

60

Incandescent

214 °F/101 °C

T5

T4

—

75

Incandescent

219 °F/104 °C

T5

T4

—

80

Mercury

268 °F/131 °C
(Ta = 104 °F/+40 °C)

T3

—

—

100

Incandescent

237 °F/114 °C

T4

T4

181 °F/83 °C

100

Mixed

257 °F/125 °C

T4

T4

212 °F/100 °C

150

Incandescent

248 °F/120 °C

T4

T4

198 °F/92 °C

1342

Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

HBN Series Round Bulkhead Luminaire Dimensions and Photometric Data

Flameproof

Dimensions in Inches/Millimeters

6.81"/173 mm

Cable Entries
Cable
entries

11.65"/296 mm

6.14"/
156 mm

0.24"/
6 mm

6.30"/
160 mm

Protectiveguard
Guard
Protective

Photometric Data ➊

Incandescent
NF C 71-120: .062 J + 0.10 T

0

185

Degrees

178
171

15

156

20

132

30

110

40

97

50

87

60

90

70

100

80

96

90

58

100

58

100°
90°
80°
70°
60°
50°

Lighting: Increased Safety/Flameproof — Bulkhead

5
10

Lighting

Candela
Distribution

40°

30°
0°	

10°	

20°

➊ Polar curves for a 1000 lm output according to NF C 71-120 Luminaire symbol according to NF C 71-121.
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

1343

HBDC Series Cylindrical Bulkhead Luminaires

Flameproof

Zone 1, 2, 21 & 22
II 2 GD
ATEX / IEC
IPP66/68 (10M) - IK08

Applications
•	
	
	
	

For illumination of:
— Stairways
— Small areas
— Emergency exit

Features
•	
	
	
	
	
•	
•	
•	
•	
•	
•	
•	
•	

For lamps:
— 70 W high pressure sodium (ovoid type E27 lampholder)
— 18/20 W compact fluorescent lamp (E27 lampholder)
— 2 x 40 W incandescent lamp (E27 lampholder)
— 8 W fluorescent bulb (G5 lampholder) (lamp supplied)
HPS version: compensated power supply 230/240 V 50 Hz 	
(+/-10%) with power factor 0.9.
Connection to plug-in terminal block via 2 x 3 terminals 	
.025 cm²/2.5 mm².
Operates in any position.
Threaded access cover with O-ring seal.
Two integrated mounting lugs.
1 external earth via .04 cm²/4 mm² bracket.
2 threaded cable entries.
Supplied with 1 plug M20 (cable gland not supplied).

70 W Sodium Version

Compact Fluorescent Version

Lighting

Standard Material
•	 End cap and cover: Zamak, anticorrosion treated and 	
painted gray
•	 Sealed tube: toughened glass
•	 External reflector: galvanized steel painted white
•	 Protective guard: zinc plated steel
•	 Lamps are not supplied except for 8 W fluorescent bulb

Options

Lighting: Increased Safety/Flameproof — Bulkhead

•	 Fixing accessories available in 316 stainless steel 	
or zinc plated steel.
•	 Fall prevention fixing kit in stainless steel.

Certifications and Compliances
•	
•	
	
	
	
•	
	
	
	
•	
•	
•	
•	
•	
•	
•	
•	
•	
•	
•	

Certification Type: FLd
Zone 1 - 2
— Conforming to ATEX 94/9/CE: CE 0081
II 2 G
— ATEX/IEC Protection: Ex d IIC
— T Rating: See Table
Zone 21 - 22
— Conforming to ATEX 94/9/CE: CE 0081
II 2 D
— ATEX/IEC Protection: Ex tD A21
— Surface Temperature: (See table)
Ambient Temperature:  -4 °F/-20 °C ≤ Ta ≤ +131 °F/55 °C
-4 °F/-20 °C ≤ Ta ≤ +131 °F/55 °C for 70W HPS
CE Declaration of Conformity: 50203
ATEX Certificate: LCIE 97/ ATEX 6012
IECEx Certificate: IECEx LCI 04.0018
Other Certifications: GOST
Index of Protection (solid & liquid): IP66 / 68 (10 m)
Impact Resistance (shock): IK08
Internal Volume: > 122 in³/2 dm3 (2 liters)
Ex Standards	 EN / IEC 60079-0; 60079-1; 61241-0; 61241-1
Product Standards: EN / IEC 60598-1
Other Standards: EN / IEC 60529 (IP); 62262 (IK)

1344

Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

HBDC Series Cylindrical Bulkhead Luminaires

Flameproof

Zone 1, 2, 21 & 22
II 2 GD
ATEX / IEC
IPP66/68 (10M) - IK08

Order using catalog numbering guide below or select catalog number from tables on following pages.
Catalog Numbering Guide
HBDC

F

1

Series:
HBDC

40

02A

Quantity of Lamps:
1 - One Lamp
2 - Two Lamp

Lamp Type:
I - Incandescent
F - Fluorescent
L - High Pressure Sodium

Voltage:
02A - 24 Vac 50/60 Hz
02D - 24 Vdc
04A - 48 Vac 50/60 Hz
04D - 48 Vdc
11A - 110 Vac 50/60 Hz
11D - 110 Vdc
24A - 230/240 Vac 50/60 Hz ➍
24B - 230/240 Vac/Vdc 50/60 Hz
Power:
40 - 40 W ➊
18 - 18/20 W ➋
70 - 70 W ➌
08 - 8 W Fluorescent

Weight
lbs/kgs

Volume
in3/dm3

Catalog
Number

Pack

2x40 W Incandescent ➎

E27

–

16/7.1

1892/31

HBDCI240

1

70 W HP Sodium ➎

E27

230/240 Vac 50 Hz

16/7.1

2014/33

HBDCL17024A

1

1x8 W Fluorescent

G5

24 Vdc

18/8.3

1892/31

HBDCF10802D

1

1x8 W Fluorescent

G5

48 Vdc

18/8.3

1892/31

HBDCF10804D

1

1x8 W Fluorescent

G5

110 Vdc

18/8.3

1892/31

HBDCF10811D

1

G5

230/240 Vac 50/60 Hz

18/8.3

1892/31

HBDCF10824B

1

18/8.3

1892/31

HBDCF20824B

1

16/7.1

2014/33

HBDCF118

1

1x8 W Fluorescent
2x8 W Fluorescent
1x18/20 W Compact Fluorescent (1)

Versions

198/254 Vdc
G5

230/240 Vac 50/60 Hz
198/254 Vdc

E27

–
Dust

Gas

Surface Temperature

T Rating

Without
External Reflector
°F/°C

With
External Reflector
°F/°C

Without
External Reflector
Ta=+104 °F/
+40 °C

Ta=+131 °F/
+55 °C

With
External Reflector
Ta=+104 °F/
+40°C

Ta=+131°F/
+55°C

Incandescent lamp (2x40 W)

203/95

203/95

T5

T5

T5

T5

Compact Fluorescent lamp (20 W max)

203/95

266/130

T6

T5

T5

T4

Fluorescent (8 W - G5 lampholder)

203/95

266/130

T6

T5

T5

T4

–

–

High Pressure Sodium Lamp (70 W ovoid)

252/122

–

T4 for Ta = +122 °F/
+50°C

➊ Incandescent Lamp
➋ Compact Fluorescent Lamp
➌ High Pressure Sodium Lamp (HP)
➍ 50 Hz only for the 70 W HPS Version
➎ Lamp not supplied
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

1345

Lighting: Increased Safety/Flameproof — Bulkhead

Voltage

Lighting

Lampholder

Lamp

HBDC Series Cylindrical Bulkhead Luminaires

Flameproof

Zone 1, 2, 21 & 22
II 2 GD
ATEX / IEC
IPP66/68 (10M) - IK08

Accessories
Catalog Number

Packing

External reflector in galvanized steel (painted white) 	
(not compatible with 70 W HPS version)

Description

FDER1G

1

Protective guard in zinc plated steel

FDPG1Z

1

Protective guard in zinc plated steel for 70 W HPS version

FDPG5Z

1

Quick one-hand fixing (Set of 2 brackets) in zinc plated steel

FDFBZ

1

Quick one-hand fixing (Set of 2 brackets) in 316 stainless steel

FDFBS

1

Fixing unit on flat surface (Set of 2 brackets) in zinc plated steel

FDSBZ

1

Fixing unit on flat surface (Set of 2 brackets) in 316 stainless steel

FDSBS

1

Fixing unit for 1"1/2 (Ø1.93"/49 mm) or 1"1/4 (Ø1.65"/42 mm) tube 	
in zinc plated steel

FDHC49Z

Fixing unit for 1"1/2 (Ø1.93"/49 mm) or 1"1/4 (Ø1.65"/42 mm) tube  	
in 316 stainless steel

FDHC49S

Fixing unit for 2" (Ø2.36"/60 mm) tube in zinc plated steel

FDHC60Z

1
1
1

Fixing unit for 2" (Ø2.36"/60 mm) tube in 316 stainless steel

FDHC60S

1

Fall prevention fixing kit (.05"/1.2 m chain) in stainless steel

FDSCS

1

Lighting

Dimensions (In/mm)
HBDCL17024A (70 W HP Sodium)
0.47"/
12 mm

0.98"/
25 mm

7.52"/191 mm

Ø0.47"/
12 mm

Lighting: Increased Safety/Flameproof — Bulkhead

0.59"/
15 mm

3.50"/
89 mm

3.35"/
85 mm

5.91"/
150 mm

0.43"/
11 mm

0.47"/
12 mm

13.19"/
335 mm
0.98"/
25 mm

3.05"/

77.5
77.5 mm

0.43"/
11 mm

Ø0.47"/
12 mm

0.20"/
5.0 mm

15.75"/

400 mm
400
mm
mini

18.50"/
470 mm

0.20"/
5.0 mm

7.52"/191 mm

5.91"/
150 mm

HBDC and HBDCF

3.05"/
77.5
77.5 mm

14.76"/
375 mm

0.59"/
15 mm

3.50"/
89 mm

15.75"/
400 mm
400
mm
mini

16.92"/
430 mm

3.35"/
85 mm

Photometric Data
Polar curves for a 1000 lm flux, according to NF C 71-120
Luminaire symbol according to NF C 71-121
70 W HP Sodium
Efficiency 59.4%
NF C 71-121: 0.56G + 0.04T

2x40 W Incandescent
Efficiency: 75.6%
NFC 71-121: 0.74G + 0.02T

Candela Distribution
0
5
10
15
20
25
30
35
40
45
50
55
60
65
70

1346

0-180 90-270
166
166
167
165
164 Degrees162
162
156
158
151
155
143
151
133
146
122
141
110
135
95
128
81
120
66
111
52
101
39
90
27

Longitudinal
Transverse

Candela Distribution
150°	 120°
105°
90°
75°
60°
45°

30°
0°	

15°

0
5
10
15
20
25
30
35
40
45
50
60
70

0-180 90-270
196 Degrees 196
197
198
196
196
193
194
189
190
181
185
176
179
170
172
163
164
155
153
145
128
123
91
99
43

100°
90°
80°
70°
60°
50°
40°
30°
0°	 10°	 20°

Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

Baymaster 250/400™ High Bay Luminaires

150 W, 250 W, 400 W HPS; 175 W, 200 W, 250 W, 320 W, 400 W, 450 W PSMH; 175 W, 250 W, 400 W MH V; 300 W-500 W Incandescent.

Applications
•	 For illumination of manufacturing, storage, and other indoor
areas.

Features

Lighting: General Lighting — Area — High Bay

•	 Standard Baymaster fixtures operate in high ambient
temperatures. All units suitable for minimum 194 °F/90 °C
supply wire.
•	 High efficiency (up to 78% with 250 W HPS lamps) with
exceptionally long lamp life—economical to own and operate.
•	 A wide range of ballasts and voltages are available for both
domestic and export applications.
•	 Integral ballast.
•	 Sockets are heavy duty mogul base, with spring loaded, nickel
plated center contact and heavy gauge, nickel plated brass
screw shell with double lamp grips to prevent lamps from
loosening due to vibration.
•	 Efficient, low glare, compact reflector.
•	 Reflector installs and adjusts to wide, medium, or narrow
distribution (without tools) by repositioning spring locks.
•	 Installation is quick and easy: 	
	(1) mount junction box to 0.75”/33.4 mm conduit 	
	(2) slide ballast onto junction box	
	(3) make connections	
	(4) install lamp	
	(5) snap reflector in place.
•	 Open-top reflector design keeps reflector clean because of
thermal barrier and chimney effect, and provides up-light to
relieve contrast.

Complete Fixture

Standard Materials
•	
•	
•	
•	

Ballast: finned, copperfree (4/10 of 1% max.) aluminum
Reflector: aluminum
Sockets: porcelain
Locks: stainless steel

Standard Finishes
•	 Ballast: white powder coat polyester
•	 Reflector: natural finished

Dimensions

12.38"/
314.5 mm

•	 All units available with a sensor circuit for automatically
lighting an auxiliary safety lamp if a power dip or lamp failure
extinguishes the HID lamp.

Lighting

Options

Ballast Housing Assembly

13.75"/349.3 mm

Certifications and Compliances
•	 UL Listed: E109438
•	 UL Standard: 1598
•	 CSA Certified: LR9349

6.25"/
158.8 mm

4.75"/349.3 mm

Related Products

5.5"/139.7 mm

•	 For power hook, fusing and other suspension accessories, see
Fixture Hanger Accessories page.

15.88"/
403.4 mm Min.
18.25"/
463.6 mm Max
10.38"/
263.7 mm

16"/
406.4 mm

Remote Ballast Mounting
V CSA Certification only.
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

1347

Baymaster 250/400™ High Bay Luminaire Performance

150 W, 250 W, 400 W HPS; 175 W, 200 W, 250 W, 320 W, 400 W, 450 W PSMH; 175 W, 250 W, 400 W MH V

150 Watt
S./M.H. †

Effic.

175 Watt
S./M.H. †

Effic.

250 Watt
S./M.H. †

400 Watt
S./M.H. †

Effic.

Distribution *

Effic.

Narrow

71.0%

.8:1

—

—

80.0%

0.6:1

80.0%

0.6:1

Medium

72.1%

1.5:1

—

—

77.5%

1.4:1

77.6%

1.4:1

Wide

73.2%

2.5:1

—

—

74.6%

2.5:1

75.4%

2.5:1

Pulse Start Metal Halide
•	 149 °F/65 °C maximum ambient temperature for 175 W-250 W
•	 131 °F/55 °C maximum ambient temperature 320 W-450 W
Distribution *

175 Watt
Effic.
S./M.H. †

200 Watt
Effic.
S./M.H. †

250 Watt
Effic.
S./M.H. †

320 Watt
Effic.
S./M.H. †

400 Watt
Effic.
S./M.H. †

450 Watt
Effic.
S./M.H. †

Narrow

67.7%

0.6:1

73.3%

0.7:1

78.6%

0.2:1

67.5%

0.7:1

67.5%

0.7:1

67.2%

0.7:1

Medium

72.3%

1.4:1

73.8%

1.7:1

75.2%

1.5:1

70.3%

1.6:1

70.6%

1.6:1

70.7%

1.4:1

Wide

74.6%

2.0:1

72.8%

2.2:1

74.1%

2.1:1

70.6%

2.1:1

71.4%

2.1:1

71.6%

2.0:1

Metal Halide V
•	 149 °F/65 °C maximum ambient temperature for 175 W-250 W
•	 131 °F/55 °C maximum ambient temperature 400 W
175 Watt

250 Watt

400 Watt

Distribution *

Effic.

S./M.H. †

Effic.

S./M.H. †

Effic.

S./M.H. †

Narrow

82.9%

0.8:1

82.9%

0.8:1

79.6%

1:1

Medium

82.8%

1.8:1

82.8%

1.8:1

77.2%

2:1

Wide

80.4%

2.4:1

80.4%

2.4:1

75.2%

2.7:1

Lighting

Lighting: General Lighting — Area — High Bay

High Pressure Sodium
•	 149 °F/65 °C maximum ambient temperature for 150 W-250 W
•	 131 °F/55 °C maximum ambient temperature 400 W

V CSA Certification only.

1348

Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

Baymaster 250/400™ High Bay Luminaire Electrical Specifications
150 W, 250 W, 400 W HPS; 175 W, 200 W, 250 W, 320 W, 400 W, 450 W PSMH; 175 W, 250 W, 400 W MH V

High Pressure Sodium — All ballasts are C.W.A. type, except 150 W HPS which is HX-Auto
150 W
Line
Volts

Start

120

2.00

250 W

Oper.

Total
Watts

Start

1.70

188

2.00

400 W

Oper.

Total
Watts

Start

Oper.

Total
Watts

2.50

295

3.30

3.80

465

208

1.15

.95

188

1.20

1.50

295

1.80

2.20

465

240

1.00

.85

188

1.00

1.30

295

1.60

1.90

465

277

.85

.72

188

.85

1.10

295

1.40

1.70

465

347 V 0.52

0.56

188

0.60

0.93

295

1.00

1.32

465

.47

189

.40

.65

295

.80

1.00

465

480

.50

Line
Volts

Start

Oper.

200 W
Total
Watts

Start

Oper.

Pulse Start Metal Halide — Super C.W.A. Ballast Amps
250 W
320 W
Total
Total
Total
Watts Start Oper. Watts Start Oper. Watts Start

400 W
Oper.

450 W
Total
Watts

Start

Oper.

Total
Watts

120

.90

1.78

199

2.10

2.00

235

1.90

2.50

288

2.60

3.25

368

3.50

4.00

454

4.00

4.40

510

208

.50

1.08

199

1.15

1.25

235

1.10

1.45

288

1.50

1.90

368

2.00

2.30

454

2.30

2.60

510

240

.35

.89

199

1.10

1.00

235

.96

1.25

288

1.30

1.65

368

1.75

2.00

454

2.00

2.20

510

277

.30

.76

199

.75

.85

235

.85

1.10

288

1.15

1.40

368

1.50

1.75

454

1.70

1.90

510

347 V 0.25

0.65

199

.25

.70

232

0.62

0.90

288

0.70

1.10

368

1.10

1.35

454

1.10

1.50

505

.50

213

.35

.50

237

.46

.60

285

.60

.80

368

.90

1.00

454

.85

1.12

514

480

.25

175 W
Line
Volts

Start

Oper.

Total
Watts

120

1.3

1.8

213

Metal Halide V — C.W.A. Ballast Amps
250 W
Total
Start Oper. Watts

Start

Oper.

Total
Watts

1.2

3.25

4.0

458

2.6

295

400 W

.75

1.1

213

.65

1.5

295

1.9

2.3

458

.65

.90

213

.60

1.3

295

1.65

2.0

458

277

.55

.78

213

.50

1.12

295

1.4

1.75

458

347

0.50

0.65

213

0.80

0.90

295

1.20

1.40

458

Lighting

208
240

V CSA Certified only.

Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

Lighting: General Lighting — Area — High Bay

175 W

1349

Baymaster 250/400™ High Bay Luminaires
Quick Estimate Illumination Charts *

Lighting

Lighting: General Lighting — Area — High Bay

150 W, 250 W, 400 W HPS; 175 W, 200 W, 250 W, 320 W, 400 W, 450 W PSMH; 175 W, 250 W, 400 W MH V

400 Watt High Pressure Sodium

400 Watt Pulse Start Metal Halide

250 Watt High Pressure Sodium

250 Watt Pulse Start Metal Halide

How to use Quick-Estimate Illumination Chart
1. Refer to “Quick-Estimate Illumination Chart” for the lamp type and wattage to be used.
2. Determine “room size”  of area to be lighted. “Small Room” is 2500 Sq. Ft. or less. “Medium Room” is 2500 Sq. Ft./232.2 Sq.M. thru
    10,000 Sq. Ft./929.0 Sq. M. A “Large Room” is 10,000 Sq. Ft./929.0 Sq. M. or more.
3. Find level of light (footcandles) required in vertical column of figures at left of chart. Then follow horizontal line (real or interpolated)
    to right until it intersects with “Arc” of selected “room size.” Come directly down from point of intersection to horizontal line of number
    “Square Feet Per Luminaire.” The resulting number (real or interpolated) is the “number of square feet” one Appleton Baymaster will
    illuminate to the selected average maintained footcandle level when  mounted in conjunction with other units in the high bay installation.
4. Divide number of total square feet in project by “number of square feet per luminaire” to get number of units required.
5. Take square root of resulting “number of square feet per luminaire” number to determine spacing between units.

* Photometric charts available on request.
V CSA Certification only.

1350

Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

Baymaster 250/400™ High Bay Luminaires

150 W, 250 W, 400 W HPS; 175 W, 200 W, 250 W, 320 W, 400 W, 450 W PSMH; 175 W, 250 W, 400 W MH V

Pendant Mounting (3/4”)
Lamp Type

Catalog Number
Ballast Housing Assembly

Voltage

Complete Assembly ➊➋

150 W HPS

120/208/240/277 V

G-HB41AL-MT

G-HB411L-MT

150 W HPS

120/277/347 V

G-HB41AL-TT V➌

G-HB411L-TT V➌

150 W HPS

480 V

G-HB41AL-48

G-HB411L-48

250 W HPS

120/208/240/277 V

G-HB61AL-MT

G-HB611L-MT

250 W HPS

120/277/347 V

250 W HPS

480 V

G-HB61AL-TT V➌
G-HB61AL-48

G-HB611L-TT V➌
G-HB611L-48

400 W HPS

120/208/240/277 V

G-HB71AL-MT

G-HB711L-MT

400 W HPS

120/277/347 V

400 W HPS

480 V

G-HB71AL-TT V➌
G-HB71AL-48

G-HB711L-TT V➌
G-HB711L-48

G-HB51AP-MT

G-HB511P-MT

G-HB51AP-TT V➌
G-HB51AP-48

G-HB511P-TT V➌
G-HB511P-48

G-HB201AP-MT

G-HB2011P-MT

G-HB201AP-TT V➌
G-HB201AP-48

G-HB2011P-TT V➌
G-HB2011P-48

G-HB61AP-MT

G-HB611P-MT

G-HB61AP-TT V➌
G-HB61AP-48

G-HB611P-TT V➌
G-HB611P-48

G-HB321AP-MT

G-HB3211P-MT

G-HB321AP-TT V➌
G-HB321AP-48

G-HB3211P-TT V➌
G-HB3211P-48

G-HB71AP-MT

G-HB711P-MT

G-HB71AP-TT V➌
G-HB71AP-48

G-HB711P-TT V➌
G-HB711P-48

G-HB451AP-MT

G-HB4511P-MT

G-HB451AP-TT V➌
G-HB451AP-48

G-HB4511P-TT V➌
G-HB4511P-48

For High Pressure Sodium Lamps

Lighting: General Lighting — Area — High Bay

For Pulse Start Metal Halide Lamps
120/208/240/277 V

175 W PSMH

120/277/347 V

175 W PSMH

480 V

200 W PSMH

120/208/240/277 V

200 W PSMH

120/277/347 V

200 W PSMH

480 V

250 W PSMH

120/208/240/277 V

250 W PSMH

120/277/347 V

250 W PSMH

480 V

320 W PSMH

120/208/240/277 V

320 W PSMH

120/277/347 V

320 W PSMH

480 V

400 W PSMH

120/208/240/277 V

400 W PSMH

120/277/347 V

400 W PSMH

480 V

450 W PSMH

120/208/240/277 V

450 W PSMH

120/277/347 V

450 W PSMH

480 V

Lighting

175 W PSMH

For Metal Halide Lamps V
175 W MH

120/208/240/277 V

G-HB51AH-MT V

G-HB511H-MT V

175 W MH

120/277/347 V

G-HB51AH-TT V➌

G-HB511H-TT V➌

250 W MH

120/208/240/277 V

G-HB61AH-MT V

G-HB611H-MT V

250 W MH

120/277/347 V

G-HB61AH-TT V➌

G-HB611H-TT V➌

400 W MH

120/208/240/277 V

G-HB71AH-MT V

G-HB711H-MT V

400 W MH

120/277/347 V

G-HB71AH-TT V➌

G-HB711H-TT V➌

➊ Add suffix -E to catalog number if provision for 250 W quartz emergency lamp is desired (lamp not included). Furnished with socket installed and pre-wired
(not available on units for remote ballast).
➋ To order fixture complete with lamp, add suffix -L to catalog number.
➌ Supplied complete with CWA Ballast. For 208, 240, 480 or 600 V CWI applications, change the -TT suffix to -C2, -C3, -C6 or -C7 as required. V
V CSA Certification only.
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

1351

Baymaster 250/400™ High Bay Luminaire Accessories and Replacement Parts
150 W, 250 W, 400 W HPS; 175 W, 200 W, 250 W, 320 W, 400 W, 450 W PSMH; 175 W, 250 W, 400 W MH V; 300 W-500 W Incandescent.

For Incandescent Lamps or HID lamps and Remote Ballast ➊
Lamp Type

Voltage

Catalog Number➑

For Incandescent Lamps or HID lamps and Remote Ballast ➊
300 W-500 W PS-35, incandescent

G-H71AM-RB

250 W-400 W, HPS

G-H71AL-RB

250 W, PSMH/MH

G-H71AM-RB

400 W, PSMH/MH

G-H71AM-RB

Accessories and Replacement Parts
Type

Description

Catalog Number

Lighting: General Lighting — Area — High Bay

Glass Lenses ➋

1.0"/
25.4 mm

With clear, thermal shock and impact
resistant glass lens.

G-HB7000-NL

With prismatic Corning-73 thermal shock
and impact resistant lens.

G-HB7000-NL3

Reflector only.

G-7AW

Aluminum, with gasket
(closes off reflector).

G-HB7000-SS

Has relamp opening, zinc plated.

G-HB7000-NG

16.06"/407.9 mm

Reflector

Socket Shroud
2.25"/
57.2 mm

3.0"/
76.2 mm

2.88"/73.2 mm
6.0"/
152.4 mm

Lighting

Wire Guard

1.0"/
25.4 mm

16.75"/
425.5 mm

Safety Cable (not shown)

G-HB7000-SC

Fuseholder
Has 9”/228.6 mm wire leads.

G-F10

Supplied with 3 feet of 16/3 SOOW cable
and FHHM-75SS cast safety hook

PWK V

1.31"/
33.3 mm

Wiring Kit (not shown)

➊ For remote ballast consult your local sales representative.
➋ Lens assemblies shown have stainless steel frame and are furnished with an aluminum socket shroud to close off reflector top (shroud shown). Can be field
installed.
V CSA Certification only.

1352

Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

Baymaster Prismatic 250/400™ High Bay Luminaires
150 W, 250 W, 400 W HPS. 400 W PSMH. 400 W MH V.

Applications
•	 For illumination of manufacturing, storage, and other indoor
areas.

Features

Lighting: General Lighting — Area — High Bay

•	 Standard Baymaster fixtures operate in 104 °F/40 °C ambient
temperatures. All units suitable for minimum 194 °F/90 °C
supply wire.
•	 High efficiency (up to 78% with 250 W HPS lamps) with
exceptionally long lamp life—economical to own and operate.
•	 A wide range of ballasts and voltages are available for both
domestic and export applications.
•	 Integral ballast.
•	 Mogul base sockets with spring loaded center contact and
heavy guage screw shell with double lamp grips to prevent
lamps from loosening due to vibration.
•	 Efficient, low glare, compact reflector is UV stabilized, 	
clear, injection molded high-temperature acrylic that provides
15-20% uplight.
•	 Reflector installs and adjusts to wide, medium, or narrow
distribution (without tools) by repositioning spring locks.
•	 Installation is quick and easy:
	 (1) mount junction box to 3/4”/19.1 mm conduit 	
	(2) slide ballast onto junction box	
	(3) make connections 	
	(4) install lamp 	
	(5) snap reflector in place
•	 Open-top reflector design keeps reflector clean because of
thermal barrier and chimney effect, and provides up-light to
relieve contrast.

Dimensions

Standard Materials
•	
•	
•	
•	

Ballast: finned, aluminum
Sockets: heavy duty porcelain
Reflector: acrylic
Locks: stainless steel

25.0"/635.0 mm
26.0"/660.4 mm

Standard Finishes

27.25"/692.2 mm

Lighting

•	 Ballast: corrosion polyester
•	 Sockets: nickel plated center contact
•	 Screws: nickel plated brass

Options
•	 All units available with a sensor circuit for automatically
lighting an auxiliary safety lamp if a power dip or lamp failure
extinguishes the HID lamp.

16.25"/
412.8 mm

Certifications and Compliances
•	 UL Listed: E109438
•	 UL Standard: 1598
•	 CSA Certified: LR9349

Related Products
•	 For power hook, fusing and other suspension accessories, see
Fixture Hanger Accessories page.

V CSA Certification only.
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

1353

Baymaster Prismatic 250/400™ High Bay Luminaires
150 W, 250 W, 400 W HPS. 400 W PSMH. 400 W MH V.

Pendant Mounting
Lamp Type

Voltage

Complete Assembly ➊

Catalog Number
Ballast Housing Assembly

Lighting: General Lighting — Area — High Bay

For High Pressure Sodium Lamps
G-HB41PL-MT

G-HB411L-MT

G-HB41PL-TT V➋

G-HB411L-TT V➋

480

G-HB41PL-48

G-HB411L-48

250 W HPS

120/208/240/277 V

G-HB61PL-MT

G-HB611L-MT

250 W HPS

120/277/347 V

G-HB61PL-TT V➋

G-HB611L-TT V➋

250 W HPS

480

G-HB61PL-48

G-HB611L-48

400 W HPS

120/208/240/277 V

G-HB71PL-MT

G-HB711L-MT

400 W HPS

120/277/347 V

G-HB71PL-TT V➋

G-HB711L-TT V➋

400 W HPS

480

G-HB71PL-48

G-HB711L-48

400 W PSMH

120/208/240/277 V

G-HB71PP-MT

G-HB711P-MT

400 W PSMH

120/277/347 V

G-HB71PP-TT V➋

G-HB711P-TT V➋

400 W PSMH

480

G-HB71PP-48

G-HB711P-48

150 W HPS

120/208/240/277 V

150 W HPS

120/277/347 V

150 W HPS

For Pulse Start Metal Halide Lamps

For Metal Halide Lamps V
400 W MH

120/208/240/277 V

G-HB71PH-MT V

G-HB711H-MT V

400 W MH

120/277/347 V

G-HB71PH-TT V➋

G-HB711H-TT V➋

Accessories

Lighting

Description

Catalog Number

16” Prismatic Reflector only.

G-7PR

16” Prismatic Reflector with clamp band and clear tempered glass lens.

G-7PR-IL V

16” Prismatic Reflector with clamp band and prismatic acrylic lens.

G-7PR-ILP V

➊ To order fixture complete with lamp, add suffix -L to catalog number.
➋ Supplied complete with CWA Ballast. For 208, 240, 480 or 600 V CWI applications, change the -TT suffix to -C2, -C3, -C6 or -C7 as required. V
V CSA Certification only.

1354

Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

Baymaster Prismatic 250/400™ High Bay Luminaire Electrical Specifications
150 W, 250 W, 400 W HPS. 400 W PSMH. 400 W MH V.

•	 Ballast has primary taps for 120, 208, 240 and 277 Volts.
•	 Add suffix -E to catalog number if provision for 150 W quartz emergency lamp is desired (lamp not included). Furnished with socket
installed and pre-wired.
•	 400 W MH lamps: some manufacturers recommend that their lamps be operated in enclosed units only—contact your lamp distributor or
lamp manufacturer for the latest safety information.
•	 To order fixture complete with lamp, add suffix -L to catalog number.
High Pressure Sodium — All ballasts are C.W.A. type, except 150 W HPS which is HX-Auto
150 W
Line
Volts

Start

Oper.

250 W
Total
Watts

Start

Oper.

400 W
Total
Watts

Start

Oper.

Total
Watts

2.00

1.70

188

2.00

2.50

295

3.30

3.80

465

1.15

.95

188

1.20

1.50

295

1.80

2.20

465

240

1.00

.85

188

1.00

1.30

295

1.60

1.90

465

277

.85

.72

188

.85

1.10

295

1.40

1.70

465

347 V 0.52

0.56

188

0.60

0.93

295

1.00

1.32

465

.47

189

.40

.65

295

.80

1.00

465

480

.50

Oper.

Total
Watts

Start

Oper.

Pulse Start Metal Halide — Super C.W.A. Ballast Amps
250 W
320 W
Total
Total
Total
Watts Start Oper. Watts Start Oper. Watts Start

.90

1.78

199

2.10

2.00

235

1.90

175 W
Line
Volts

Start

120

200 W

2.50

288

2.60

3.25

368

3.50

400 W

450 W

Oper.

Total
Watts

Start

Oper.

Total
Watts

4.00

454

4.00

4.40

510

208

.50

1.08

199

1.15

1.25

235

1.10

1.45

288

1.50

1.90

368

2.00

2.30

454

2.30

2.60

510

240

.35

.89

199

1.10

1.00

235

.96

1.25

288

1.30

1.65

368

1.75

2.00

454

2.00

2.20

510

277

.30

.76

199

.75

.85

235

.85

1.10

288

1.15

1.40

368

1.50

1.75

454

1.70

1.90

510

347 V 0.25

0.65

199

.25

.70

232

0.62

0.90

288

0.70

1.10

368

1.10

1.35

454

1.10

1.50

505

.50

213

.35

.50

237

.46

.60

285

.60

.80

368

.90

1.00

454

.85

1.12

514

480

.25

Line
Volts

Start

Oper.

Total
Watts

Lighting

175 W

Metal Halide V — C.W.A. Ballast Amps
250 W
Total
Start Oper. Watts

Start

400 W
Oper.

Total
Watts

120

1.3

1.8

213

1.2

2.6

295

3.25

4.0

458

208

.75

1.1

213

.65

1.5

295

1.9

2.3

458

240

.65

.90

213

.60

1.3

295

1.65

2.0

458

277

.55

.78

213

.50

1.12

295

1.4

1.75

458

347

0.50

0.65

213

0.80

0.90

295

1.20

1.40

458

V CSA Certified only.
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

Lighting: General Lighting — Area — High Bay

120
208

1355

Baymaster Prismatic 250/400™ High Bay Luminaires
Quick-Estimate Illumination Charts *

Lighting

Lighting: General Lighting — Area — High Bay

150 W, 250 W, 400 W HPS. 400 W PSMH. 400 W MH V.

400 Watt High Pressure Sodium

400 Watt Pulse Start Metal Halide

250 Watt High Pressure Sodium

250 Watt Pulse Start Metal Halide

How to use Quick-Estimate Illumination Chart
1.	 Refer to “Quick-Estimate Illumination Chart” for the lamp type and wattage to be used.
2.	 Determine “room size”  of area to be lighted. “Small Room” is 2500 Sq. Ft. or less. “Medium Room” is 2500 Sq. Ft. thru 10,000 Sq. Ft. A
“Large Room” is 10,000 Sq. Ft. or more.
3.	 Find level of light (footcandles) required in vertical column of figures at left of chart. Then follow horizontal line (real or interpolated) to
right until it intersects with “Arc” of selected “room size.” Come directly down from point of intersection to horizontal line of number
“Square Feet Per Luminaire.” The resulting number (real or interpolated) is the “number of square feet” one Appleton Baymaster will
illuminate to the selected average maintained footcandle level when  mounted in conjunction with other units in the high bay installation.
4.	 Divide number of total square feet in project by “number of square feet per luminaire” to get number of units required.
5.	 Take square root of resulting “number of square feet per luminaire” number to determine spacing between units.
* Photometric charts available on request.

* Photometric charts available on request.
V CSA Certification only.

1356

Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

Baymaster Prismatic 250/400™ High Bay Luminaire Photometric Data *
150 W, 250 W, 400 W HPS. 400 W PSMH. 400 W MH V.

Square Steel Poles for Davit Mount Luminaires
Typical Footcandle Values

30
—
—
—
—
—
—
—
—
—
—
—
.01
.01
.02
.03
.05
.07
.10
.14
.23
.55

40
—
—
—
—
—
.01
.01
.01
.02
.03
.04
.05
.06
.08
.10
.21
.37
.60
.91
1.35
1.91

50
.01
.01
.01
.02
.02
.03
.03
.04
.05
.06
.10
.17
.26
.38
.54
.74
1.00
1.29
1.62
2.05
2.69

400 Watt High Pressure Sodium
60
.02
.03
.03
.04
.04
.06
.09
.14
.20
.27
.35
.46
.60
.77
.93
1.13
1.37
1.66
2.02
2.16
2.21

Lighting: General Lighting — Area — High Bay

165
160
155
150
145
140
135
130
125
120
115
110
105
100
95
90
85
80
75
70
65

Mounting Height Feet

Distance in terms of mounting height ◊

Distance (ft)
Ahead/
Behind
Footcandle

Distance in terms of mounting height ◊

1.06

2.53

9.07

2.21

1.85

3.39

3.17

2.18

400 W HPS

50
45
40
35
30
25
20
15
10
5
0
-5
-10
-15
-20
-25
-30

3.08
4.51
6.64
8.65
8.85
8.95
9.25
11.4
13.7
12.7
6.58
1.15
.60
.77
1.13
1.11
.85

4.55
4.93
4.98
4.98
5.04
5.49
6.41
7.47
7.67
6.53
3.70
.81
.40
.31
.43
.59
.70

3.19
3.16
3.23
3.18
3.63
4.10
4.64
4.95
4.83
3.93
2.37
.58
.33
.23
.21
.26
.35

2.34
2.24
2.31
2.57
2.85
3.16
3.43
3.41
3.18
2.60
1.65
.48
.29
.18
.15
.15
.19

Mtg. Ht.
20
25
30
35
40
45

Ft. Candles for Iso-Footcandle Lines
A
29.03
18.58
12.90
9.48
7.26
5.73

B
20.21
12.91
8.98
6.60
5.05
4.00

C
19.19
12.28
8.53
6.27
4.80
3.79

D
8.07
5.16
3.59
2.63
2.02
1.59

E
2.39
1.53
1.06
.78
.60
.47

F

G
.39
.25
.17
.13
.10
.08

H
.17
.11
.08
.06
.04
.03

.04
.04
.03
.02
.02
.01

This report has been prepared in accordance with IES guides on testing procedures. It is
representative of luminaires tested under standardized and stabilized laboratory conditions.
Various operating factors can cause differences between laboratory data and actual field
performance.

◊ Distance in terms of mounting height (i.e., ratio) of distance to height. Example: @ 15 foot/4.6 meters mounting height, 1 means 15 foot/4.6 meters; 2 means
30 foot/9.1 meters, etc.
* Additional photometric charts available on request.
V CSA Certification only.
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

1357

Lighting

60
55

Super-Baymaster High Bay Luminaires V

High Bay Luminaires for Mill Duty and Corrosive Atmospheres
150 W, 175 W, 250 W, 400 W or 1000 W HID lamps.

Applications
•	 For illumination of mills (pulp and paper), manufacturing, storage
and other areas where corrosion, moisture or dust present
severe problems.
•	 CSA approved weatherproof (Encl. 3) with open reflector and
dust-tight (Encl. 3 and 5) with enclosing lens.
•	 Will operate safely in temperatures ranging from -40 °F/-40 °C
to +149 °F/+65 °C ambient.

Lighting

Lighting: General Lighting — Area — High Bay

Features
•	 Corrosion resistant. All external surfaces of the ballast housing
are coated with a heavy-duty epoxy-finish providing 	
durability and resistant to both alkali and acidic atmospheric
conditions. To suit specific atmospheric requirements, 	
consult the factory for a suitable finish.
•	 High efficiency reflectors (up to 76% with 1000 W MH lamps)
and ­exceptionally long HID lamp life make Super-­Baymaster
luminaires unusually economical to own and operate.
•	 The Baymaster reflector is a unique ­design that combines high
efficiency with low glare in a compact size.
•	 Super-Baymaster luminaires are furnished with open reflectors.
For enclosed reflectors, clear or prismatic glass are available.
•	 Pre-wired with high temperature fixture wire, these integral
ballasted luminaires are supplied with dual-tap primary for 120
or 240 Volt lines or with 208, 277 or 347 Volt primary. Ballasts
are highest quality, Class H insulated, CWA and CWI types,
­thermally isolated for cooler operating and 	
long life. Grounding wire provided.
•	 To protect the internal components of the luminaire from
corrosive atmospheres all mating surfaces are gasketed.
•	 Mogul base socket with spring loaded center contact and heavy
gauge, screw shell with double lamp grips to prevent lamps
from loosening due to vibration.
•	 Installation is quick and easy:
(1) lift ­ballast assembly onto the hanger hub and rotate 60° until
sealed on hub
(2) tighten locking nut (hand tight) to secure ballast assembly
(3) make supply connections (90° wire) and replace wiring cover
(4) snap reflector in place
(5) install lamp

Shown with optional lens: 1000 W
Dimensions
Height
20-7/8"/530.4 mm; 150-400 W MV/MH
19-11/16"/500.1 mm; 1000 W
Width
16"/406.4 mm; 150-400 W
20"/508.0 mm; 1000 W
Height
29"/736.6 mm; 150-400 W MV/MH
31"/787.4 mm; 1000 W

Standard Materials
•	 Reflector: aluminum
•	 Sockets: porcelain

Width
16"/406.4 mm; 150-400 W
20"/508.0 mm; 1000 W

Standard Finishes
•	 Screws: nickel plated brass
•	 Housing: epoxy powder coated external surfaces

Options
•	 Quartz auxiliary: units are available with a pre-wired sensor
circuit for automatically lighting a quartz auxiliary lamp when
power dip or lamp failure extinguishes the main HID lamp.
•	 Fuse kits: for grounded systems.
•	 Lenses: clear or prismatic glass with heavy-duty, stainless steel
clips to secure lens to reflector.
•	 HPS units available with a pulse ­eliminator which effectively
shuts down the ballast assembly when lamp fails.
•	 Optional finishes may be ordered to suit specific environments
in regular or ­specific colors.

Certifications and Compliances
•	
•	
•	
•	

UL Listed: E109938
UL Standard: 1598
CSA Certified: 009349
CSA Standard: C22.2 No. 250.0

Related Products
•	 For power hook, fusing and other suspension accessories, see
Fixture Hanger Accessories page.

V CSA Certification only.

1358

Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

Super-Baymaster High Bay Luminaires V

High Bay Luminaires for Mill Duty and Corrosive Atmospheres
150 W, 175 W, 250 W, 400 W or 1000 W HID lamps.

Order using catalog numbering guide below or select catalog number from tables on following pages.
Catalog Numbering Guide for GSB and GSS
GSB

4

Series:
GSB – SuperBaymaster
GSS – SuperBaymaster
Side by Side

1

A

Beam Spread:
1 – Narrow (not for
1000 W)
2 – Medium
3 – Wide

C

Lamp Type:
L – High Pressure Sodium
H – Metal Halide
M – Mercury Vapour
P – Pulse Start Metal Halide

Reflector:
A – Complete with reflector
Blank – Ballast assembly only

MT

E

Voltage:
MT – 120, 208,
240, 277V
CWA
TT –  120, 277,
347V CWA
208 – 208 Volts
RB –  Remote
Ballast

Ballast Type:
C – CWI
A – CWA

Voltage:
E – Provision for 250 W
quartz emergency
lamp (pre-wired)
S – Provision for pulse
eliminator
F – Fuse for grounded
systems (single
pole)
LC – Gasketed clear
lens assembly
LP – Gasketed
prismatic lens
assembly
CR – Corrosion
resistant epoxy
paint on reflector
exterior surface

Lighting: General Lighting — Area — High Bay

Wattage:
4 – 150 watt
5 – 175 watt
6 – 250 watt
7 – 400 watt
8 – 1000 watt

L

Accessories and Replacement Parts
Description

Catalog Number

With relamp door. Zinc plated

G-HB-20-G

Safety Chain

Secures ballast and reflector

G-HB-7000-SC

Wiring Kit

Supplied with 3 feet of 600V –194 °F/90
°C 3-conductor no. 16 SOW cable and
3/4”/19.1 mm FHHM hook (shipped
­separately) Add Suffix:

Lighting

Wire Guard

PWK

Sockets
Socket for Metal Halide and Mercury Vapor

SPF-1004

Socket for High Pressure Sodium

SPF-1001

V CSA Certification only.
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

1359

Super-Baymaster High Bay Luminaires V

High Bay Luminaires for Mill Duty and Corrosive Atmospheres
150 W, 175 W, 250 W, 400 W or 1000 W HID lamps.

Luminaire Performance
Distribution 

150 Watt
Effic.
S./M.H. 

200 Watt
Effic.
S./M.H. 

250 Watt
Effic.
S./M.H. 

400 Watt
Effic.
S./M.H. 

1000 Watt
Effic.
S./M.H. 

High Pressure Sodium
Narrow

66.3%

0.5:1

66.4%

0.5:1

68.9%

0.5:1

66.4%

0.5:1

—

—

Medium

71.3%

1.1:1

71.4%

1.1:1

74.4%

1.7:1

71.4%

1.1:1

71.3%

0.7:1

Wide

73.3%

2.0:1

73.4%

2.0:1

78.0%

2.0:1

73.5%

2.0:1

74.4%

1.4:1

Effic.

175 Watt
S./M.H. 

Effic.

250 Watt
S./M.H. 

Effic.

400 Watt
S./M.H. 

Effic.

1000 Watt
S./M.H. 

Metal Halide
Narrow

61.8%

0.4:1

66.7%

0.4:1

61.9%

0.6:1

—

—

Medium

66.1%

1.0:1

70.2%

1.0:1

66.3%

1.5:1

76.2%

1.1:1

Wide

66.1%

2.0:1

75.2%

2.2:1

66.3%

2.2:1

75.4%

2.5:1

Mercury Vapor
Narrow

73.0%

0.8:1

53.2%

0.8:1

73.1%

1.2:1

—

—

Medium

73.5%

1.1:1

63.2%

1.1:1

73.6%

1.4:1

72.1%

1.5:1

Wide

74.2%

1.7:1

68.0%

1.7:1

74.2%

1.7:1

69.5%

1.8:1

Quick-Estimate Illumination Charts 
1000 Watt High Pressure Sodium

1000 Watt Metal Halide

1000 Watt Mercury Vapor

Lighting

Lighting: General Lighting — Area — High Bay

Distribution 

How to use Quick-Estimate Illumination Chart
1.	Refer to “Quick-Estimate Chart” for the lamp to be used.
2.	Determine “room size” of area to be lighted. “Small Room” is 2500 Sq. Ft./232.3 Sq. M. or less. “Medium Room” is 2500 Sq. M./232.3
Sq. M. thru 10,000 Sq. Ft./929.0 Sq. M. “Large Room” is 10,000 Sq. Ft./929.0 Sq.M. or more.
3.	Find level of light (footcandles) required in vertical column of figures at left of chart. Then follow horizontal line 	
(real or ­interpolated) to right until it intersects with “Arc” of selected “room size.” Come directly down from point 	
of intersection to horizontal line of number “Square Feet Per Luminaire”. The resulting number (real or interpolated) 	
is the ­“number of square feet” one Appleton Baymaster will illuminate to the selected average maintained footcandle 	
level when mounted in ­conjunction with other units in the high bay installation.
4.	Divide number of total square feet in project by “number of square feet per luminaire” to get number of units required.
5.	Take square root of resulting “number of square feet per ­luminaire” number to determine spacing between units.

 S./M.H.: Spacing to Mounting Height.
 Photometric charts available on request.
V CSA Certification only.

1360

Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

Baymaster 1000™ High Bay Luminaires
1000 W HPS; 1000 W MH; 750 W, 1000 W, 1500 W PS-52 Incandescent.

Applications
•	 Ideal for aircraft hangars, machine shops, foundries and other
large-area working environments.

Features

Complete Fixture

Standard Materials
•	
•	
•	
•	
•	

Ballast: finned, aluminum
Sockets: porcelain, nickel plated center contact
Screws: brass
Reflectors: aluminum
Locks: stainless steel

Lighting: General Lighting — Area — High Bay

•	 Standard Baymaster fixtures operate in high ambient
temperatures.
•	 High efficiency (up to 76% with 1000 W metal halide lamps) with
exceptionally long lamp life makes these Baymaster fixtures
unusually economical to own and operate.
•	 A wide range of ballasts and voltages are available for both
domestic and export applications.
•	 Integral ballast.
•	 Mogul base socket with spring loaded center contact and heavy
gauge, screw shell with double lamp grips to prevent lamps
from loosening due to vibration.
•	 The Baymaster reflector is a unique design that combines high
efficiency with low glare in a compact size.
•	 Reflector installs and adjusts to wide or medium distribution
(without tools) by repositioning spring locks.
•	 Installation is quick and easy:
(1) lift ballast assembly onto the hanger hub and rotate 60° until
seated on hub
(2) tighten locking nut (hand tight) to secure ballast assembly
(3) make supply connections (194 °F/90 °C wire) and replace
wiring cover
(4) snap reflector in place
(5) install lamp
•	 Open-top reflector design keeps reflector clean because of
thermal barrier and chimney effect, and provides up-light to
relieve contrast.

Ballast Housing Assembly
Dimensions

Ballast: corrosion polyester
Sockets: nickel plated center contact
Screws: nickel plated
Reflectors: natural finish

26.81”/681.0 mm Min. — 29”/736.6 mm Max.

•	
•	
•	
•	

Options
•	 Units are available with a pre-wired sensor circuit for
automatically lighting an auxiliary safety lamp in case a power
dip or lamp failure extinguishes the HID lamp.

Certifications and Compliances
•	 UL Listed: E109438
•	 UL Standard: 1598 (supersedes UL Standard 1572)
•	 CSA Certified: LR9349

Related Products
•	 For power hook, fusing and other suspension accessories, see
Fixture Hanger Accessories page.

Lighting

Standard Finishes

20.0"/508.0 mm

Standard Baymaster 1000 fixtures operate
efficiently in high 131 °F/55 °C ambient temperatures.

Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

1361

Baymaster 1000™ High Bay Luminaires
1000 W HPS; 1000 W MH; 750 W, 1000 W, 1500 W PS-52 Incandescent.

Pendant Mounting (3/4”)
Lamp Type

Catalog Number
Complete Assembly ②
Ballast Housing Assembly

Voltage

For High Pressure Sodium Lamps — Complete with ballast
G-HB81AL-MT

G-HB811L-MT

G-HB81AL-TT V

G-HB811L-TT V

480 V

G-HB81AL-48

G-HB811L-48

1000 W MH 

120/208/240/277 V

G-HB81AH-MT

G-HB811H-MT

1000 W MH 

120/277/347 V

1000 W MH 

480 V

1000 W HPS

120/208/240/277 V

1000 W HPS

120/277/347 V

1000 W HPS

Lighting

Lighting: General Lighting — Area — High Bay

For Metal Halide Lamps — Complete with ballast

G-HB81AH-TT V

G-HB811H-TT V

G-HB81AH-48

G-HB81A1H-48

750 W, 1000 W or 1500 W PS-52 Incandescent

G-H81AM-RB

G-H811M-RB

1000 W High Pressure Sodium

G-H81AL-RB

G-H811L-RB

1000 W Metal Halide

G-H81AH-RB

G-H811H-RB

For Incandescent Lamps or HID Lamps — Ballast Remote — Ballast not included

Electrical Specifications
Line Volts
120

High Pressure Sodium — C.W.A.  Ballast Amps — 1000 W
Start
Oper.
Total Watts
6.35

9.50

Metal Halide — C.W.A.  Ballast Amps — 1000 W
Start
Oper.
Total Watts

1100

8.00

9.20

1080

208

3.80

5.50

1100

4.60

5.30

1080

240

3.20

4.80

1100

4.00

4.60

1080

277

2.75

4.20

1100

3.50

4.00

1080

347

2.80

3.00

1100

2.00

3.20

1080

480

1.80

2.45

1100

2.00

2.30

1080

Luminaire Performance
1000 W
Distribution 

Effic.

S./M.H. 

High Pressure Sodium
Medium

71.3%

7:1

Wide

74.4%

1.4:1

Medium

76.2%

1.1:1

Wide

75.4%

2.5:1

Metal Halide

 1000 W MH Lamps: some manufacturers recommend that their lamps be operated in enclosed units only—select enclosing lens
from list of accessories. Contact your electrical lamp distributor or lamp manufacturer for the latest safety information.
 Add suffix -E to catalog number if provision for quartz emergency lamp is desired (lamp not included). Furnished with socket installed and pre-wired.
 Supplied complete with C.W.A. Ballast. For 208, 240, 480 or 600 V C.W.I. applications, change the -TT suffix to -C2, -C3, -C6 or -C7 as required. V
 C.W.A. is Constant Wattage Autotransformer.
 Reflector adjusts for Medium to Wide distribution without tools.
 S./M.H.: Spacing to Mounting Height.
V CSA Certification only.

1362

Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

Baymaster 1000™ High Bay Luminaires Accessories and Replacement Parts
1000 W HPS; 1000 W MH; 750 W, 1000 W, 1500 W PS-52 Incandescent.

Description

Catalog Number ➊

Wire Guard
Zinc plated.

G-HB-20-NG

1.0"/
25.4 mm

21.0"/
533.4 mm

Hinged Lens — Complete with Socket Schroud
Thermal shock and impact resistant, clear
glass lens.

G-HB-20-NL

Thermal shock and impact resistant,
Corning-73 lens.

G-HB-20-NL3

Aluminum (closes off reflector).

G-HB7000-SS

20.06"/
509.5 mm

Lighting: General Lighting — Area — High Bay

1.0"/
25.4 mm

Socket Shroud
2.25"/
57.2 mm

3.0"/
76.2 mm
2.88"/
73.2 mm

6.0"/
152.4 mm

Safety Cable (not shown)

G-HB7000-SC

Reflector
G-8AW

Supplied with 3 feet of 16/3 SOOW cable
and FHHM-75SS cast safety hook

PWK V

Lighting

Reflector only.

Wiring Kit (not shown)

➊ Other accessories available for 20”/508 mm 1000 W Baymasters include emergency lighting circuits, unit fuses, and special hanger hardware. Contact your
local sales representative.
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

1363

Baymaster 1000™ High Bay Luminaires
Quick Estimate Illumination Charts *

1000 W HPS; 1000 W MH; 750 W, 1000 W, 1500 W PS-52 Incandescent.

1000 Watt Metal Halide

How to use Quick-Estimate Illumination Chart
1.	 Refer to “Quick-Estimate Illumination Chart” for the lamp type and wattage to be used.
2.	 Determine “room size”  of area to be lighted. “Small Room” is 2500 Sq. Ft. or less. “Medium Room” is 2500 Sq. Ft./232.3 Sq. M. thru
10,000 Sq. Ft./929.0 Sq. M. A “Large Room” is 10,000 Sq. Ft./929.0 Sq. M. or more.
3.	 Find level of light (footcandles) required in vertical column of figures at left of chart. Then follow horizontal line (real or interpolated) to
right until it intersects with “Arc” of selected “room size.” Come directly down from point of intersection to horizontal line of number
“Square Feet Per Luminaire.” The resulting number (real or interpolated) is the “number of square feet” one Appleton Baymaster will
illuminate to the selected average maintained footcandle level when  mounted in conjunction with other units in the high bay installation.
4.	 Divide number of total square feet in project by “number of square feet per luminaire” to get number of units required.
5.	 Take square root of resulting “number of square feet per luminaire” number to determine spacing between units.

Lighting

Lighting: General Lighting — Area — High Bay

1000 Watt High Pressure Sodium

* Photometric charts available on request.

1364

Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

Lumenmaster 250™ Low Bay HID Prismatic Luminaires
Integrally Ballasted. 150 W, 250 W HPS; 175 W, 200 W, 250 W PSMH, 175 W, 250 W MH V.

Suitable for use in damp locations

Applications
•	 Energy-efficient, low-glare illumination for manufacturing,
storage and other indoor areas where low bay luminaires are
required. Can be mounted as low as 8 feet/2.4 meters from
work plane.
•	 Suitable for use in damp locations.
•	 Operates safely in ambients as high as 104 °F/40 °C.
•	 Applications involving airborne particulates (such as carbon
black, pigments, etc.) should be pre-evaluated and approved 	
by Appleton prior to ordering.

Features

Dimensions
/8"/
12-3 mm
314.4

6-1/4"/
158.8 mm

26-3/4"/
679.5 mm
16.0"/
406.4 mm

Standard Materials
•	
•	
•	
•	
•	

Lighting: General Lighting — Area — Low Bay

•	 High efficiency (up to 74.6% with 250 W high pressure
sodium lamp) combined with long lamp life, ensures the most
economical operation.
•	 Two-to-one vertical-to-horizontal footcandles provides effective,
efficient illumination of vertical surfaces.
•	 Reflector/refractor optical assembly is computer designed for
uniform, wide light distribution with low glare.
•	 Injection-molded prismatic refractor lens is 100% virgin acrylic.
Minimum thickness is 3/16”/4.8mm.
•	 Ruggedly built, attractively styled, low-profile design.
•	 A wide range of ballasts and voltages are available for both
domestic and export applications.
•	 Integral ballast.
•	 Capable of starting and operating the lamp in temperatures as
low as -20 °F/-28.9 °C for pulse start metal halide lamps,
-40 °F/-40 °F for high pressure sodium lamps.
•	 Mogul base socket with spring loaded center contact and heavy
gauge, screw shell with double lamp grips to prevent lamps
from loosening due to vibration.
•	 Installation is quick and easy:
	 (1) mount junction box to 3/4”/19.1 mm conduit 	
(2) slide ballast onto junction box 	
(3) make connections 	
(4) install lamp 	
(5) snap reflector in place
Gasket: silicone rubber
Reflector: aluminum
Ballast housing: finned, coppefree (4/10 of 1% max) aluminum
Sockets: porcelain
Screws: brass

20.0"/
508.0 mm

Standard Finishes
•	
•	
•	
•	

Reflector: natural finish
Ballast: white powder coat polyester
Sockets: nickel plated center contact
Screws: nickel plated brass

•	 Units are available with a pre-wired sensor circuit for
automatically lighting an auxiliary safety lamp in case a power
dip or lamp failure extinguishes the HID lamp.

Related Products
• For power hook, fusing and other suspension accessories see
Fixture Hanger Accessories.

Certifications and Compliances
•	 UL Listed: E85142
•	 UL Standard: 1598
•	 CSA Certified: LR9349

V CSA Certification only.
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

1365

Lighting

Options

Lumenmaster 250™ Low Bay HID Prismatic Luminaires
Integrally Ballasted. 150 W, 250 W HPS; 175 W, 200 W, 250 W PSMH, 175 W, 250 W MH V.

Suitable for use in damp locations

Electrical Specifications
High Pressure Sodium — All ballasts are C.W.A. type, except 150 W HPS which is HX-Auto

Lighting: General Lighting — Area — Low Bay

150 W

250 W

Line Volts

Start

Oper.

Total
Watts

Start

Oper.

Total
Watts

120

2.00

1.70

188

2.00

2.50

295

208

1.15

.95

188

1.20

1.50

295

240

1.00

.85

188

1.00

1.30

295

277

.85

.72

188

.85

1.10

295

347 V

0.52

0.56

188

0.60

0.93

295

480

.50

.47

189

.40

.65

295

Line
Volts

Pulse Start Metal Halide — Super C.W.A. Ballast Amps
175 W
200 W
Total
Total
Start
Oper.
Watts
Start
Oper.
Watts

Start

Oper.

Total
Watts

120

.90

1.78

199

2.10

2.00

235

1.90

2.50

288

208

.50

1.08

199

1.15

1.25

235

1.10

1.45

288

240

.35

.89

199

1.10

1.00

235

.96

1.25

288

277

.30

.76

199

.75

.85

235

.85

1.10

288

347 V

0.25

0.65

199

.25

.70

232

0.62

0.90

288

480

.25

.50

213

.35

.50

237

.46

.60

285

Metal Halide V — C.W.A. Ballast Amps
175 W
Total
Oper.
Watts

250 W

250 W
Start

Oper.

Total
Watts

213

1.2

2.6

295

1.1

213

.65

1.5

295

.90

213

.60

1.3

295

.55

.78

213

.50

1.12

295

0.50

0.65

213

0.80

0.90

295

Line
Volts

Start

120

1.3

1.8

208

.75

240

.65

277
347
Luminaire Performance
150 Watt
S./M.H.
Effic.


Lighting

Distribution


175 Watt
S./M.H.
Effic.


200 Watt
S./M.H.
Effic.


250 Watt
S./M.H.
Effic.


High Pressure Sodium
70.0%

3.2:1

—

—

—

—

74.6%

3.1:1

Pulse Start Metal Halide
—

—

65.9%

2.7:1

53.1%

3.1:1

67.2%

3.0:1

—

—

62.3%

2.6:1

—

—

64.7%

3.0:1

Metal Halide
 Reflector adjusts for medium to wide distribution without tools.
 S./M.H.: Spacing to Mounting Height.
V CSA Certified only.

1366

Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

Lumenmaster 250™ Low Bay HID Prismatic Luminaires
Integrally Ballasted. 150 W, 250 W HPS; 175 W, 200 W, 250 W PSMH, 175 W, 250 W MH V.

Suitable for use in damp locations

Pendant Mounting

Lamp Type

Voltage

Catalog Number
Complete with Reflector/Refractor
Assembly and Ballast 

Ballast Housing
Assembly

For High Pressure Sodium Lamps
150 W HPS

120/208/240/277 V 

150 W HPS

120/277/347 V 

G-LM41AL-MT

G-LM411L-MT

G-LM41AL-TT V④

G-LM411L-TT V④

150 W HPS

480 V 

G-LM41AL-48

G-LM411L-48

250 W HPS

120/208/240/277 V

G-LM61AL-MT

G-LM611L-MT

250 W HPS

120/277/347 V

G-LM61AL-TT V④

G-LM611L-TT V④

250 W HPS

480 V

G-LM61AL-48

G-LM611L-48

175 W PSMH

120/208/240/277 V

G-LM51AP-MT

G-LM511P-MT

175 W PSMH

120/277/347 V

G-LM51AP-TT V④

G-LM511P-TT V④

G-LM51AP-48

G-LM511P-48

G-LM201AP-MT

G-LM2011P-MT

For Pulse Start Metal Halide Lamps

480 V
120/208/240/277 V

200 W PSMH

120/277/347 V

G-LM201AP-TT V④

G-LM2011P-TT V④

200 W PSMH

480 V

G-LM201AP-48

G-LM2011P-48

250 W PSMH

120/208/240/277 V

G-LM61AP-MT

G-LM611P-MT

250 W PSMH

120/277/347 V

G-LM61AP-TT V④

G-LM611P-TT V④

250 W PSMH

480 V

G-LM61AP-48

G-LM611P-48

Lighting: General Lighting — Area — Low Bay

175 W PSMH
200 W PSMH

For Metal Halide Lamps V
175 W MH

120/208/240/277 V

G-LM51AH-MT V

G-LM511H-MT V

175 W MH

120/277/347 V

G-LM51AH-TT V④

G-LM511H-TT V④

250 W MH

120/208/240/277 V

G-LM61AH-MT V

G-LM611H-MT V

250 W MH

120/277/347 V

G-LM61AH-TT V④

G-LM611H-TT V④

Lighting

 For 150 W HPS fixtures furnished with Instant Hot Restart, add suffix -R to catalog number.
 Add Suffix -E to catalog number if provision for quartz emergency lamp is desired (lamp not included). Furnished with socket installed and pre-wired.
 To order fixture complete with lamp, add suffix -L to catalog number.
④ Supplied complete with CWA Ballast. For 208, 240, 480 or 600 V CWI applications, change the -TT suffix to -C2, -C3, -C6 or -C7 as required. V
V CSA Certification only.
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

1367

Lumenmaster 250™ Low Bay HID Prismatic Luminaires
Integrally Ballasted. 150 W, 250 W HPS; 175 W, 200 W, 250 W PSMH, 175 W, 250 W MH V.

Accessories and Replacement Parts
Type

Description

Catalog Number

Fuseholder with 9” wire leads

G-F10

Zinc plated.
"/
16 m
5/ m
1- 3.3
3

Safety Cable (not shown)

G-HB7000-SC

Optic Assembly

Optic Assembly only.

G-LM20

Supplied with 3 feet of 16/3 SOOW cable and FHHM-75SS cast safety
hook

PWK V

Lighting

Lighting: General Lighting — Area — Low Bay

Wiring Kit (not shown)

V CSA Certification only.

1368

Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

Lumenmaster 250™ Low Bay HID Prismatic Luminaires
Integrally Ballasted. Quick-Estimate Illumination Chart *
Integrally Ballasted. 150 W, 250 W HPS; 175 W, 200 W, 250 W PSMH.

250 Watt High Pressure Sodium

150 Watt High Pressure Sodium

250 Watt Pulse Start Metal Halide

175 Watt Pulse Start Metal Halide

Lighting: General Lighting — Area — Low Bay

How to use Quick-Estimate Illumination Chart
1.	 Refer to “Quick-Estimate Illumination Chart” for the lamp type and wattage to be used.
2.	 Determine “room size” of area to be lighted. “Small Room” is 2500 Sq. Ft./232.3 Sq. M. or less. “Medium Room” is 2500 Sq. Ft./232.3
Sq. M. thru 10,000 Sq. Ft./929.0 Sq. M. “Large Room” is 10,000 Sq. Ft./929.0 Sq.M. or more.
3.	 Find level of light (footcandles) required in vertical column of figures at left of chart. Then follow horizontal line 	
(real or interpolated) to right until it intersects with “Arc” of selected “room size.” Come directly down from point 	
of intersection to horizontal line of number “Square Feet Per Luminaire.” The resulting number (real or interpolated) is 	
the “number of square feet” one Appleton will illuminate to the selected average maintained footcandle level when 	
mounted in conjunction with other units in the high bay installation.
4.	 Divide number of total square feet in project by “number of square feet per luminaire” to get number of units required.
5.	 Take square root of resulting “number of square feet per luminaire” number to determine spacing between units.

Lighting

* Photometric charts available on request. Consult your local sales representative for pulse start metal halide.
V CSA Certification only.
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

1369

Lumenmaster 400™ Low Bay HID Prismatic Luminaires
Integrally Ballasted. 400 W, 250 W HPS; 320 W, 400 W PSMH. 400 W MH V.

Suitable for use in damp locations

Applications
•	 Energy-efficient, low-glare illumination for manufacturing,
storage and other indoor areas where low bay luminaires are
required. Can be mounted as low as 8 feet/2.4 meters from
work plane.
•	 Suitable for use in damp locations.
•	 Operates safely in ambients as high as 104 °F/40 °C
•	 Applications involving airborne particulates (such as carbon
black, pigments, etc.) should be pre-evaluated and approved by
Appleton prior to ordering.

Lighting: General Lighting — Area — Low Bay

Features
•	 High efficiency (up to 81.6% with 400 W high pressure
sodium lamp) combined with long lamp life, ensures the most
economical operation.
•	 Two-to-one vertical-to-horizontal footcandles provides effective,
efficient illumination of vertical surfaces.
•	 Reflector/refractor optical assembly is computer designed for
uniform, wide light distribution with low glare.
•	 Injection-molded prismatic refractor lens is 100% virgin acrylic.
Minimum thickness is 3/16”/4.8 mm.
•	 A wide range of ballasts and voltages are available for both
domestic and export applications.
•	 Integral ballast.
•	 Capable of starting and operating the lamp in temperatures as
low as -20 °F/-28.9 °C for pulse start metal halide lamps,
-40 °F/-40 °C for high pressure sodium lamps.
•	 Mogul base sockets with spring loaded center contact and
heavy gauge screw shell with double lamp grips to prevent
lamps from loosening due to vibration.
•	 Installation is quick and easy:
	 (1) mount junction box to 3/4”/4.8 mm conduit 	
(2) slide ballast onto junction box	
(3) make connections 	
(4) install lamp 	
(5) snap reflector in place

6.25"/
158.8 mm

12.38"/
314.5 mm

26.0"/660.4 mm

Standard Materials
•	
•	
•	
•	
•	

15.25"/
387.4 mm

Gasket: silicone rubber
Reflector: aluminum
Ballast: finned, copperfree (4/10 of 1% max.) aluminum
Sockets: heavy duty porcelain
Screws: brass

30.0"/
762.0 mm

Standard Finishes
•	
•	
•	
•	

Reflector: natural finish
Ballast: white powder coated polyester
Sockets: nickel plated center contact
Screws: nickel plated

Options
Lighting

Dimensions

•	 Units are available with a pre-wired sensor circuit for
automatically lighting an auxiliary safety lamp in case a power
dip or lamp failure extinguishes the HID lamp.

Related Products
•	 For power hook, fusing and other suspension accessories, see
Fixture Hanger Accessories page.

Certifications and Compliances
•	 UL Listed: E85142
•	 UL Standard: 1598
•	 CSA Certified: LR9349

V CSA Certification only.

1370

Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

Lumenmaster 400™ Low Bay HID Prismatic Luminaires
Integrally Ballasted. 400 W, 250 W HPS; 320 W, 400 W PSMH. 400 W MH V.

Suitable for use in damp locations

Pendant Mounting

Lamp Type

Voltage

Catalog Number
Complete with Reflector/Refractor
Assembly and Ballast 

Ballast Housing
Assembly

For High Pressure Sodium Lamps
250 W HPS

120/208/240/277 V

250 W HPS

120/277/347 V

250 W HPS

480 V

400 W HPS

120/208/240/277 V

400 W HPS

120/277/347 V

400 W HPS

480 V

G-LM61BL-MT

G-LM611L-MT

G-LM61BL-TT V④

G-LM611L-TT V④

G-LM61BL-48

G-LM611L-48

G-LM71BL-MT

G-LM711L-MT

G-LM71BL-TT V④

G-LM711L-TT V④

G-LM71BL-48

G-LM711L-48

G-LM321BP-MT

G-LM3211P-MT

For Pulse Start Metal Halide Lamps
320 W PSMH

120/208/240/277 V

320 W PSMH

120/277/347 V

320 W PSMH

480 V

400 W PSMH

120/208/240/277 V

400 W PSMH
400 W PSMH

G-LM321BP-TT V④

G-LM3211P-TT V④

G-LM321BP-48

G-LM3211P-48

G-LM71BP-TT V④

G-LM711P-MT

120/277/347 V

G-LM71BP-MT

G-LM711P-TT V④

480 V

G-LM71BP-48

G-LM711P-48

400 W MH

120/208/240/277 V

G-LM71BH-MT V

G-LM711H-MT V

400 W MH

120/277/347 V

G-LM71BH-TT V④

G-LM711H-TT V④

Lighting: General Lighting — Area — Low Bay

For Metal Halide Lamps V

Accessories and Replacement Parts 
Type

Description

Catalog Number

Fuseholder with 9” wire leads

Zinc plated.

G-F10

"/
16 m
5/ m
1- 3.3
3

Safety Cable (not shown)

G-HB7000-SC

Optic Assembly

G-LM30

Lighting

Optic Assembly only.

Wiring Kit (not shown)
Supplied with 3 feet of 16/3 SOOW cable and FHHM-75SS cast
safety hook

PWK V

 To order fixture complete with lamp, add suffix -L to catalog number.
 Add Suffix -E to catalog number if provision for quartz emergency lamp is desired (lamp not included). Furnished with socket installed and pre-wired.
 For power hook, fusing and other suspension accessories, see Fixture Hanger Accessories.
④ Supplied complete with CWA Ballast. For 208, 240, 480 or 600 V CWI applications, change the -TT suffix to -C2, -C3, -C6 or -C7 as required. V
V CSA Certification only.
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

1371

Lumenmaster 400™ Low Bay HID Prismatic Luminaires
Integrally Ballasted. 400 W, 250 W HPS; 320 W, 400 W PSMH. 400 W MH V.

Suitable for use in damp locations

Electrical Specifications
High Pressure Sodium — All ballasts are C.W.A. type, except 150 W HPS which is HX-Auto
Line Volts

Start

250 W
Oper.

120

2.00

2.50

Total Watts

Start

400 W
Oper.

Total Watts

295

3.30

3.80

465

208

1.20

1.50

295

1.80

2.20

465

240

1.00

1.30

295

1.60

1.90

465

277

.85

1.10

295

1.40

1.70

465

347 V

0.60

0.93

295

1.00

1.32

465

480

.40

.65

295

.80

1.00

465

Pulse Start Metal Halide — Super C.W.A. Ballast Amps
320 W
Start
Oper.
Total Watts
Start

400 W
Oper.

Total Watts

4.00

454

Line
Volts

Lighting: General Lighting — Area — Low Bay

120

2.60

3.25

368

3.50

208

1.50

1.90

368

2.00

2.30

454

240

1.30

1.65

368

1.75

2.00

454

277

1.15

1.40

368

1.50

1.75

454

347 V

0.70

1.10

368

1.10

1.35

454

480

.60

.80

368

.90

1.00

454

Line
Volts

Start

400 W
Oper.

Total Watts

120

3.25

4.0

458

208

1.9

2.3

458

240

1.65

2.0

458

Metal Halide V — C.W.A. Ballast Amps

277

1.4

1.75

458

347

1.20

1.40

458

Luminaire Performance 

Lighting

Distribution

Effic.

250 Watt
S./M.H. 

Effic.

320 Watt
S./M.H. 

Effic.

400 Watt
S./M.H. 

High Pressure Sodium
Wide

81.7%

2.0:1

—

—

81.6%

2.0:1

—

—

63.7%

2.3:1

63.2%

2.3:1

—

—

—

—

81.4%

1.7:1

Pulse Start Metal Halide
Wide
Metal Halide V
Wide

V CSA Certified only.

1372

Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

Lumenmaster 400™ Low Bay HID Prismatic Luminaires
Integrally Ballasted. Quick Estimate Illumination Charts *
Integrally Ballasted. 400 W, 250 W HPS; 320 W, 400 W PSMH. 400 W MH V.

250 Watt High Pressure Sodium

400 Watt High Pressure Sodium

320 Watt Pulse Start Metal Halide

400 Watt Pulse Start Metal Halide

* Photometric charts available on request. Consult your local sales representative for pulse start metal halide.
 Consult your local sales representative for performance with 400 W mercury vapor lamps.
 S./M.H.: Spacing to Mounting Height.
V CSA Certified only.
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

1373

Lighting

Candlepower Distribution of 400 W HPS Luminaire — Closed Bottom Acrylic — All data based on clear, mogul base lamp
Fixture Efficiency: 81.6%
Zone
Candlepower
Zone
Candlepower
5
7861
95
667
15
7806
105
328
25
9774
115
184
35
11404
125
82
45
10612
135
32
55
7257
145
20
65
4998
155
0
75
3214
165
0
85
1625
175
0

Lighting: General Lighting — Area — Low Bay

How to use Quick-Estimate Illumination Chart
1.	 Refer to “Quick-Estimate Illumination Chart” for the lamp type and wattage to be used.
2.	 Determine “room size” of area to be lighted. “Small Room” is 2500 Sq. Ft./232.3 Sq. M. or less. “Medium Room” is 2500 Sq. Ft./232.3
Sq. M. thru 10,000 Sq. Ft./929.0 Sq. M. “Large Room” is 10,000 Sq. Ft./929.0 Sq. M. or more.
3.	 Find level of light (footcandles) required in vertical column of figures at left of chart. Then follow horizontal line 	
(real or interpolated) to right until it intersects with “Arc” of selected “room size.” Come directly down from point 	
of intersection to horizontal line of number “Square Feet Per Luminaire.” The resulting number (real or interpolated) is 	
the “number of square feet” one Appleton will illuminate to the selected average maintained footcandle level when 	
mounted in conjunction with other units in the high bay installation.
4.	 Divide number of total square feet in project by “number of square feet per luminaire” to get number of units required.
5.	 Take square root of resulting “number of square feet per luminaire” number to determine spacing between units.

Fixture Hanger Accessories

Baymaster, Lumenmaster, Super-Baymaster

Catalog Number
Voltage

Fits Hubbell Plug No.

Pendant

Feed-Thru

GHPHP Pendant with one 3/4”/19.1 mm hub, GHPHT with two 3/4”/19.1 mm hubs
Furnished with assembled FS box, EFHM safety lock, receptacle and steel cover. Supports 200 lbs/90.7 kgs.

8.50"/
215.9 mm

6.06"/
153.9 mm

120

L5-15P

GHPHP12

GHPHT12

208, 240

L6-15P

GHPHP24

GHPHT24

277

L7-15P

GHPHP27

GHPHT27

480

L8-20P

GHPHP48

GHPHT48

Voltage

Fits Hubbell Receptacle No.

Cord Length
Ft/M

Catalog Number

2/.6
3/.9
4/1.2
2/.6
3.9
4/1.2
2/.6
3/.9
4/1.2
2/.6
3/.9
4/1.2

G-HCPL-2-12
G-HCPL-3-12
G-HCPL-4-12
G-HCPL-2-24
G-HCPL-3-24
G-HCPL-4-24
G-HCPL-2-27
G-HCPL-3-27
G-HCPL-4-27
G-HCPL-2-48
G-HCPL-3-48
G-HCPL-4-48
Catalog Number

Lighting: General Lighting — Area — Low Bay

Matching Cord Sets for above Receptacle Hangers
120

L5-15R

208, 240

L6-15R

277

L7-15R

480

L8-20R

Size
(Inches)

Length (A)
Inch/Millimeters

Support Wt.
Lbs/Kgs

3.88/98.6
4.13/104.9

350/158.8

FHLM-50
FHLM-75

350/158.8

FHLF-75

3.88/98.6
4.13/104.9

200/90.7

FHHM-50
FHHM-75

3.25/82.6
3.25/82.6

200/90.7

FHHF-50
FHHF-75

FH—Hanger Loops With 5/8”/16.0 mm wire opening
FHLM—Male
1/2
3/4
FHLF—Female
1/2
3/4

FHLF-50

3.25/82.6
3.25/82.6

FH—Hanger Hooks With 5/8”/16.0 mm wire opening, 3/8”/19.1 mm jaw opening
FHHM—Male
Lighting

1/2
3/4
FHHF—Female
1/2
3/4

Fuse and Cartridge — Cartridges are furnished complete with two 10”/254 mm-long high temperature wire leads and 600 Volt fuse

1374

6 Amp

G-F6

10 Amp

G-F10

20 Amp

G-F20

30 Amp

G-F30

Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

Quartzlite™ 50 Floodlight
300 W thru 500 W quartz tungsten halogen.

Applications
•	 Recreation — fun after dark with illuminated swimming pools,
basketball, and other court and play areas.
•	 Beauty — illuminate your home, patio and garden to maximize
the beauty of your home.
•	 Safety — eliminate night-time hazards with lighting on outdoor
stairways, walkways, and driveways.
•	 Security — illuminate backyards, entrance ways and other
areas for protection against intruders.
•	 Saves energy.

Features
•	 Uses standard household current (120 Volts, 120 Vac).
•	 Strong, compact, lightweight fixture can be installed 	
anywhere outdoors.
•	 Bright anodized aluminum parabolic reflector for efficient 	
light distribution.
•	 Lamp held securely in spring-loaded porcelain socket 	
for positive contact.
•	 Flowing lines for an attractive appearance blend with 	
any architectural style.
•	 Reinforcing rib keeps lens door flat against housing.
•	 Door hinges cast permanently as part of the housing securely
anchor door, yet entire door can be removed if desired.
•	 Easy to install 1/2” NPT thread with locknut.
•	 Attaches to standard electrical box cover plate (not furnished).
Only two wires plus ground to connect.

Dimensions
9.0"/
228.6 mm

7.75"/196.9 mm

2.13"/
54.1 mm

Standard Materials
•	
•	
•	
•	

5.63"/143.0 mm

0.5"/12.7 mm

Housing and lens door: single pressure — cast aluminum piece
Lens: heat/shatter resistant glass
Slotted/hex screw:
Adjustable swivel mount

Certifications and Compliances

Description

NEMA Type

Lumens

Max.

Candlepower
Average Max.

Catalog Number
With Lamp
Without Lamp

(Illumination based on use of T-3 Quartz Tungsten Halogen Lamps)

Wide Beam

5x5

6,846

Mounting
Angle

Mounting Height
ft/m

Area Illuminated
Width x Depth
ft/m

8,416

7,685

G-50-5-L120

G-50-5

Mounting
Angle

Mounting Height
ft/m

Area Illuminated
Width x Depth
ft/m

12/3.7

70x70/
21.3x21.3

12/3.7

80x75/
24.4x22.9

16/4.9

80x80/
24.4x24.4

16/4.9

90’x85’
27.4x25.9

20/6.1

100x80/
30.5x24.4

20/6.1

100’x90’
30.5x27.4

Lighting: General Lighting — Area — Floodlights

•	 UL Listed: E22558
•	 UL Standard: 1598
•	 CSA Certified: LR9349

Lighting

Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

1375

Quartzlite™ 500/1500 Floodlight
300 W thru 1500 W quartz tungsten halogen lamps.

Applications
•	 Heavy duty, weatherproof floodlights for industrial, commercial,
and sports applications where efficient, controlled distribution is
required. Widely used for:
	 — Sports and amusement areas
	 — Sign lighting
	 — Parking lots
	 — Accent lighting
	 — Security lighting
	 — Similar applications
Quartzlite™ 500
Projected Area:
1.2 Sq. Ft/0.14 Sq. M

Features
•	 Choice of mounting fittings and accessories to meet 	
installation needs.
•	 Rugged, compact, lightweight design; easy to install and
maintain. Cool operating, long lamp life.
•	 Quartzlite 500 uses 500 W or 300 W 120 Volts or 130V T-3 	
quartz tungsten halogen lamps with exceptional efficiency 	
and economy.
•	 Quartzlite 1500 uses T-3 quartz tungsten halogen lamps.
Available for use with 1500 W lamps for 208, 220, 240, and 277
Volt operation; for 1250 W lamps, 208 Volt operation; and for
1000 W lamps, 220 or 240 Volts operation.
•	 1500 W unit housing has integral fins for maximum heat
dissipation. Hinged door has thermal shock and impact
resistant glass lens.

Dimensions
9.88"/
251 mm

/27

75"
3.1
mm

Lighting: General Lighting — Area — Floodlights

4.5"/
114.3 mm

10.

Lighting

4.75"/
120.7 mm
15.25"/387.4 mm

Standard Materials
•	 Housing and lens door: rugged, corrosion resistant, one-piece
pressure-cast aluminum
•	 Hex-head bolts: two 5/16"/8.0 mm
•	 Thermal shock and impact resistant glass
•	 Gasket: heavy, one-piece silicone rubber to resist high
temperatures
•	 Reflector: precision parabolic design, natural finish aluminum
for maximum efficiency
•	 Swivel mounting arm: heavy duty, degree-marked swivel
mounting arm with 3/4”/19.1 mm pipe thread and locknut

•	 UL Listed: E22558
•	 UL Standard: 1598
•	 CSA Certified: LR9349

Beam Spread
Horizontal

Vertical

2.75"/69.9 mm

Certifications and Compliances

•	 Housing and hinged lens door: architectural bronze polyester
finish

NEMA Type

11"/279.4 mm

9.5"/
241.3 mm

Standard Finishes

Description

Quartzlite™ 1500
Projected Area:
0.7 Sq. Ft/0.07 Sq. M

Lumens

Candlepower
Average
Maximum
Maximum

Catalog Number
With Lamp

Without
Lamp

(Illumination based on use of T-3 Quartz tungsten Halogen lamps)

Quartzlite™ 1500
Wide Beam

6x6

128.0°

103.0°

23,218

18,689

17,564

Quartzlite 500
Wide

5x5

95°

92°

6,846

8,416

7,685

G-1500L240 ➊
G-1500L277 ➋

G-1500-➌

™

G-500-5-L130 ➍

G-500-5 ➎

➊ Furnished with 1500 W lamps for 240 V line operation.
➋ Furnished with 1500 W lamps for 277 V line operation.
➌ For 1500 W lamps for 208, 220, 240 or 277 V line operation; 1250 W lamps for 208 V line operation; 1000 W lamps for 220 or 240 V line operation.
➍ Furnished with 500 W lamps for 120 or 130 V line operation.
➎ For 300 W or 500 W lamps for 120 or 130 V line operation.

1376

Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

Quartzlite™ 500/1500 Floodlight Mounting Fittings and Accessories
300 W thru 1500 W quartz tungsten halogen lamps.

Description

Catalog Number

Crossarm Mount and Wiring Compartment
2.63"/
66.8 mm
1.88"/
47.8 mm
3.0"/
76.2 mm

180° horizontal position scale, mounts with bolt (not furnished).
Aluminum with architectural bronze polyester finish. Includes cord
grip.

G-6028N

Mounts on 1” to 2”/25.4 to 50.8 mm pipe, vertical or horizontal,
or mounts on flat surfaces (used with G-6028N). Includes U-bolts
and bolt for G-6028N. Malleable iron, zinc plated, chromate sealed,
architectural bronze polyester finish.

G-VB101

500 W

GMM4V

500 W

G-506

Extruded aluminum, with slide-off cover. Has six 3/4”/19.1 mm
threaded holes, with three close-up plugs. Mounts five 500 W or
four 1500 W Quartzlites. Mounts on 3/4”/19.1 mm conduit or G-810
poletop fitter.

G-6017

Cast aluminum, for mounting to 1-1/2” or 2”/38.1 to 50.8 mm pip
Has setscrews for securing to pole, 3/4”/19.1mm tapped top hub to
accommodate Quartzlite or Channel Crossarm above. Architectural
bronze polyester finish.

G-810

3.88"/
98.6 mm

Pipe or Wall Mount Bracket
4.0"/
101.6 mm
3.75"/
95.3 mm

4.25"/108.0 mm

Top Visor
5.0"/
127 mm
2.5"/
63.5 mm
8.63"/
219.2 mm

Wire Guard

Channel Crossarm
2.75"/
69.9 mm

2.5"/63.5 mm

Lighting: General Lighting — Area — Floodlights

26.0"/
660.4 mm

Poletop Fitter
3.0"/
76.2 mm

2.25"/
57.2 mm

Replacement Lens Frame Assembly
500 W

G5005RFL

1500 W

G1500RFL

500 W

601252002

1500 W

601252001

Replacement Lens

Lighting

Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

1377

Quartzlite™ 500/1500 Floodlights
Quick — Estimate Illumination Table *
300 W thru 1500 W quartz tungsten halogen lamps.

Quartzlite™ 500
Beam Spread

Lighting: General Lighting — Area — Floodlights

Wide

D=10 Feet/3.0 Meters

D=20 Feet/6.1 Meters

B

L

W

X

A

B

L

W

X

A

B

L

W

X

77

44

24/
7.3

19/
5.8

10/
3.0

19

11

48/
14.6

38/
11.6

21/
6.4

5

3

96/
29.3

77/
23.5

42/
12.8

D=80 Feet/24.4 Meters
A
Wide

D=40 Feet Spread/12.2 Meters Spread

A

1.2

D=100 Feet/30.5 Meters

B

L

W

X

.7

192/
58.5

153/
46.6

83/
25.3

A
.8

D=200 Feet/71.0 Meters

B

L

W

X

.4

240/
73.2

190/
57.9

104/
31.7

A
.2

B

L

W

X

.1

481/
146.6

383/
116.7

208/
63.4

Quartzlite™ 500
Beam Spread
Wide

D=10 Feet/3.0 Meters
A
176

D=20 Feet/6.1 Meters

B

L

W

X

74

33/
10.1

24/
7.3

13/
4.0

A
44

D=80 Feet/24.4 Meters

Wide

D=40 Feet Spread/12.2 Meters Spread

B

L

W

X

19

67/
20.4

48/
14.6

25/
7.6

A
11

D=100 Feet/30.5 Meters

B

L

W

X

5

133/
40.5

95/
29.0

51/
15.5

D=200 Feet/71.0 Meters

A

B

L

W

X

A

B

L

W

X

A

B

L

W

X

3

1.2

266/
81.1

191/
58.2

102/
31.1

1.7

0.7

333/
101.5

238/
72.5

127/
38.7

.4

.2

666/
203.0

477/
145.4

255/
77.7

Lighting

Note: To simplify proper beam overlapping, the size of “X” has been determined so that footcandles at edge (B) are approximately 1/3 of center intensity (A).

* Photometric charts available on request.

1378

Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

Areamaster Jr.™ HID Wide-Beam Floodlights
Integrally Ballasted. 150 W, 100 W, 70 W, 50 W HPS; 100 W PSMH. Medium Base.

Applications
•	 Available for use with HPS or PSMH medium base lamps.
•	 HPS luminaires, with their superior energy efficiency are
excellent for such applications as:
	 — Security lighting
	 — Small sports areas
	 — Parking areas
	 — Apartment complexes
	 — Hotels and motels
	 — Work area lighting
	 — Accent, building facade and sign lighting
•	 PSMH luminaires, with their near perfect color rendition, are
recommended for:
	 — Car lots
	 — Garden shops
	 — Small sports areas
	 — Billboards
	 — Building facades
	 — Airports
	 — Security areas
•	 HPS and PSMH floodlights replace higher wattage, inefficient
quartz and PAR lighting.
•	 Suitable for use in wet locations.

Projected Area: 0.7 Sq. Ft.

Features

Standard Materials
•	 Ballast housing, door and mounting arm: diecast heavy gauge
aluminum
•	 Reflector: heavy gauge aluminum
•	 Lens: heat- and impact-resistant tempered glass
•	 Gasket: heavy, high temperature silicone rubber

Standard Finishes
•	 Reflector: diffused anodized natural finish
•	 Housing, lens door and mounting arm: architectural bronze
polyester finish

Certifications and Compliances
•	 UL Standard: 1598 (supersedes UL Standard 1572).
•	 Suitable for use in wet locations
•	 CSA Certified: LR9349

Lighting: General Lighting — Area — Floodlights

•	 HPS units use approximately 80% less energy than
incandescent PAR-38 lamps and 70-75% less than quartz
lamps. In lumen output, the 50 W HPS unit is comparable to
two 150 W PAR 38 incandescent lamps; 70 W HPS to 300 W
T-3 quartz; and 100 W HPS to 500 W T-3 quartz.
•	 Beam pattern is NEMA Type 7.
•	 Extra-compact, high efficiency floodlights designed specifically
for the small size of HID medium base lamps.
•	 Compact size permits use of existing poles for retrofitting quartz
fixtures.
•	 Ruggedly built for dependable, vandal-resistant service.
Attractively styled. Easy to install, aim, and service, with easy
access to interior.
•	 Durable architectural bronze polyester finish resists chipping,
peeling and fading no matter what the weather or climate
conditions.
•	 Mounting arm: heavy duty, degree-marked swivel mounting arm
with 3/4” pipe thread and locknut. Allows vertical and horizontal
adjustment. Order mounting accessories separately.
•	 Medium base porcelain socket with nickel-plated contacts.
Rated for 4-KV pulse. Furnished with 392 °F/200 °C leads, prewired to the ballast.
•	 Reflector: precision parabolic design, natural finish, aluminum
for maximum efficiency.
•	 Patented hinged door has thermal shock and impact resistant
glass lens, secured within diecast aluminum frame with two
captive stainless hex head steel screws for watertight fit.
•	 HPF ballasts have non-PCB capacitors.

Lighting

Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

1379

Areamaster Jr.™ HID Wide-Beam Floodlights
Integrally Ballasted. 150 W, 100 W, 70 W, 50 W HPS; 100 W PSMH. Medium Base.

Description

Line Voltage

Catalog Number

Pulse Start Metal Halide Fixtures
100 Watt Metal Halide HX-Auto Ballast, High Power Factor

120

G-MM350H-12H ➊➋

50 Watt High Pressure Sodium Reactor Ballast

120

G-MM150L-12R

50 Watt High Pressure Sodium Reactor Ballast, High Power Factor

120

G-MM150L-12RH ➊

70 Watt High Pressure Sodium Reactor Ballast

120

G-MM250L-12R

70 Watt High Pressure Sodium Reactor Ballast, High Power Factor

120

G-MM250L-12RH ➊

100 Watt High Pressure Sodium Reactor Ballast

120

G-MM350L-12R

100 Watt High Pressure Sodium Reactor Ballast, High Power Factor

120

G-MM350L-12RH ➊➋

150 Watt High Pressure Sodium Reactor Ballast

120

G-MM450L-12R

150 Watt High Pressure Sodium Reactor Ballast, High Power Factor

120

G-MM450L-12RH ➊➋

High Pressure Sodium Fixtures

Accessories and Replacement Parts

Lighting

Lighting: General Lighting — Area — Floodlights

Description

Catalog Number

Crossarm Mount
Has wiring compartment, 180° horizontal position scale. Mounts with bolt (not
furnished). Aluminum. Includes cord grip.

G-6028N

Channel Crossarm
Extruded aluminum, with slide-off cover. Six 3/4” threaded holes, with three
close-up plugs. Mounts five luminaires. Mounts on 3/4” conduit or on G-810
poletop fitter.

G-6017

Pipe or Wall Mount Bracket
Mounts on 1” to 2” pipe, vertical or horizontal, or mounts on flat surfaces (used
with G6028N) Includes U-bolts and bolt for G-6028N. 	
Malleable iron.

G-VB101

Poletop Fitter
Cast aluminum, for mounting to 1-1/2” or 2” pipe. Has setscrews for securing
to pole. 3/4” tapped top hub to accommodate luminaire or Channel Crossarm
above.

G-810

Wire Guard
Mounts to lens door with screws furnished. Zinc plated.

G-506

Top Visor
Aluminum. Easy to install with hardware supplied.

G-MM4V

Vandal Shield
UV stabilized polycarbonate, with installation hardware and instructions.

G-MM-4-VS

Replacement Lens and Frame Assembly

G5005RFL

Replacement Lens Only

59601252002

➊ 208 V, 240 V or 277 V also available. For 208 V, change voltage suffix -12 to -20; for 240 V, change -12 to -24; and for 277 V, change -12 to -27.
➋ For 347 V, change voltage suffix -12H to -34 V.

1380

Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

Areamaster Jr.™ HID Wide-Beam Floodlight Specifications
Integrally Ballasted. 150 W, 100 W, 70 W, 50 W HPS; 100 W PSMH. Medium Base.

Line Voltage

Type of Ballast

Starting Amps

Operating Amps

Total Watts

HX-Auto, High Power Factor

1.22/.44

1.15/.50

129

100-Watt Metal Halide
120

150-Watt High Pressure Sodium
120

Reactor

4.50

3.20

170

120

Reactor, High Power Factor

2.20

1.50

170

100-Watt High Pressure Sodium
120

Reactor

3.05

2.10

115

120

Reactor, High Power Factor

1.50

1.05

115

70-Watt High Pressure Sodium
120

Reactor

2.10

1.60

83

120

Reactor, High Power Factor

0.89

0.75

86

120

Reactor

1.80

1.18

62

120

Reactor, High Power Factor

0.95

0.55

60

50-Watt High Pressure Sodium

Dimensions

Channel Crossarm

Pipe/Wall Mount Bracket

Lighting: General Lighting — Area — Floodlights

Crossarm Mount

Poletop Fitter

Lighting

Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

1381

Areamaster Jr.™ HID Wide-Beam Floodlight Photometric Data
Integrally Ballasted. 150 W, 100 W, 70 W, 50 W HPS; 100 W PSMH. Medium Base.

Fixture Wattage and HID Lamp—All Medium Base Clear. All Fixtures produce NEMA Type 7 Beam Pattern.
Photometric Data
Horizontal Spread
Beam Lumens
Beam Efficiency
Maximum CP
Average Maximum CP
Total Lumens
Total Efficiency

150 W HPS
146°
10,150
63%
5750
5317
10,422
65%

100 W HPS
146°
6036
64%
3415
3158
6186
65%

70 W HPS
146°
3676
63%
2084
1927
3746
65%

50 W HPS
146°
2536
63%
1437
1328
2576
64%

100 W PSMH
136°
4864
68%
3039
2581
4972
69%

Candlepower Distribution All data based on fixture with clear medium base lamp
100-Watt Metal Halide
0° Candela Table
Angle
Horizontal
-85.5
102
-76.5
175
-67.5
1224
-58.5
1972
-49.5
2319
-40.5
2707
-31.5
3302
-22.5
4091
-13.5
4888
-4.5
5334
0.0
5388
4.5
5334
13.5
4888
22.5
4091
31.5
3302
40.5
2707
49.5
2319
58.8
1972
67.5
1224
76.5
175
85.5
102

Vertical
13
112
450
774
1280
2070
3838
4842
5252
5390
5388
5390
5252
4842
3838
2070
1280
774
450
112
13

0° Candela Table
Angle
Horizontal
-85.5
61
-76.5
104
-67.5
727
-58.5
1171
-49.5
1378
-40.5
1608
-31.5
1961
-22.5
2430
-13.5
2903
-4.5
3168
0.0
3200
4.5
3168
13.5
2903
22.5
2430
31.5
1961
40.5
1608
49.5
1378
58.5
1171
67.5
727
76.5
104
85.5
61

Vertical
8
67
267
459
760
1229
2280
2876
3119
3201
3200
3201
3119
2876
2280
1229
760
459
267
67
8

0° Candela Table
Angle
Horizontal
-76.6
96
-68.0
233
-60.0
415
-52.0
772
-44.0
1471
-36.0
2226
-28.0
2641
-20.0
2729
-12.0
2537
-4.0
2296
0.0
2273
4.0
2296
12.0
2537
20.0
2729
28.0
2641
36.0
2226
44.0
1471
52.0
772
60.0
415
68.0
233
76.0
96

Vertical
11
285
417
536
660
1269
1442
1662
1957
2226
2273
2226
1957
1662
1442
1269
660
536
417
285
11

100-Watt High Pressure Sodium

Lighting

Lighting: General Lighting — Area — Floodlights

150-Watt High Pressure Sodium

1382

Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

Beam-Master™ Floodlights
General Purpose and Heavy Duty.

Ballast for 400 W PSMH; 1000 W, 1500 W MH; 400 W, 1000 W HPS.

Applications
•	
	
	
	
	
	
	
	

To illuminate large areas such as:
— Building facades
— Ship loading docks
— Truck terminals
— Security lighting
— Airports
— Athletic stadiums
— Sports fields

Features

Mounting Options

Poletop Slip-Fitter Mounting

Crossarm Mounting

Lighting: General Lighting — Area — Floodlights

•	 General purpose and heavy duty units available for 400 W
PSMH,  1000 W or 1500 W metal halide lamps or 400 W and
1000 W high pressure sodium lamps. Choice of five different
NEMA beam spreads (1000 W HPS, two beam spreads; 400 W
MH, three beam spreads.)
•	 Compact design combines reflector assembly and ballast
housing as a single unit — easier to wire and install.
•	 Balanced weight distribution allows swing-over design for 	
easy relamping and servicing.
•	 Sturdy and rugged — withstands high vibration and rugged
usage.
•	 Breather openings allow unit to breathe, yet keep dirt and
moisture out.
•	 Floodlights have aiming device, plus 180° vertical positioning
scale. Fully adjustable horizontally with crossarm bracket or
poletop mount.
•	 Swing-over design with a “memory” locking device for accurate
return to pre-aimed position after servicing.
•	 Mogul base porcelain socket has heavy gauge brass, nickel
plated, double lamp-grip screw shell and spring-loaded center
contact.
•	 Heavy duty models have heavy shroud for protection against
severe weather, such as high winds and hail.
•	 Cord enters through a weatherproof cord grip.
•	 Yoke is rugged 6061-T6 aluminum alloy. Crossarm bracket and
poletop slip-fitter are malleable iron.
•	 Ballasts are Class H insulated, UL Listed, C.W.A. type, available
multi-tapped 120, 208, 240, or 277 Volts, or single-tap for 480
Volts.

Standard Materials
•	
•	
•	
•	
•	
•	

Refllectors: aluminum
Lens: shock and impact resistant glass
Gasket: one-piece silicone rubber gasket
Frame and clamps: stainless steel
Socket/ballast: cast aluminum
Housing: mallaeble Iron

Standard Finishes
•	 Reflectors: natural finish
•	 Ballast: white powder coated polyester finish
•	 Housing: zinc plated, chromate sealed, architectural bronze
polyester finish

Certifications and Compliances
•	 UL Listed: E85142
•	 UL Standard: 1598
•	 CSA Certified: LR9349

Lighting

Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

1383

Beam-Master™ Floodlights
General Purpose and Heavy Duty.

Ballast for 400 W PSMH; 1000 W, 1500 W MH; 400 W, 1000 W HPS.

Candlepower
NEMA
Beam Spread
Beam
Type
Horiz x Vert.
Lumens Beam Effic. Avg. Max. CP
Max CP
With Ballast for 1000 W Metal Halide Lamp
II

20.2° x 21.1°

37,577

34.2%

1,332,312

1,547,349

III

45.1° x 45.1°

55,104

50.1%

481,977

638,600

IV

58.6° x 59.3°

61,562

56.0%

213,277

266,126

V

73.6° x 74.0°

66,843

60.8%

128,822

160,661

VI

111.5° x 111.2°

74,020

67.3%

76,050

82,363

Line
Voltage
120/208/240/277

Catalog Number
General Purpose
Heavy Duty
G-SM821H-MTN ➊
G-SM821H-48N

G-SM821HH-MTN ➊
G-SM821HH-48N

G-SM831H-MTN ➊
G-SM831H-48N

G-SM831HH-MTN ➊
G-SM831HH-48N

G-SM841H-MTN ➊
G-SM841H-48N

G-SM841HH-MTN ➊
G-SM841HH-48N

G-SM851H-MTN ➊
G-SM851H-48N

G-SM851HH-MTN ➊
G-SM851HH-48N

G-SM861H-MTN ➊
G-SM861H-48N

G-SM861HH-MTN ➊
G-SM861HH-48N

G-SM921H-MTN ➊
G-SM921H-48N

G-SM921HH-MTN ➊
G-SM921HH-48N

G-SM931H-MTN ➊
G-SM931H-48N

G-SM931HH-MTN ➊
G-SM931HH-48N

G-SM941H-MTN ➊
G-SM941H-48N

G-SM941HH-MTN ➊
G-SM941HH-48N

G-SM951H-MTN ➊
G-SM951H-48N

G-SM951HH-MTN ➊
G-SM951HH-48N

G-SM961H-MTN ➊
G-SM961H-48N

G-SM961HH-MTN ➊
G-SM961HH-48N

G-SM721P-MTN ➊
G-SM721P-48N

G-SM721PH-MTN ➊
G-SM721PH-48N

480

G-SM751P-MTN ➊
G-SM751P-48N

G-SM751PH-MTN ➊
G-SM751PH-48N

120/208/240/277

G-SM761P-MTN ➊

G-SM761PH-MTN ➊

120/208/240/277

G-SM851L-MTN ➊
G-SM851L-48N

G-SM851LH-MTN ➊
G-SM851LH-48N

G-SM861L-MTN ➊
G-SM861L-48N

G-SM861LH-MTN ➊
G-SM861LH-48N

G-SM721L-MTN ➊
G-SM721L-48N

G-SM721LH-MTN ➊
G-SM721LH-48N

G-SM731L-MTN ➊
G-SM731L-48N

G-SM731LH-MTN ➊
G-SM731LH-48N

G-SM741L-MTN ➊
G-SM741L-48N

G-SM741LH-MTN ➊
G-SM741LH-48N

G-SM751L-MTN ➊
G-SM751L-48N

G-SM751LH-MTN ➊
G-SM751LH-48N

G-SM761L-MTN ➊
G-SM761L-48N

G-SM761LH-MTN ➊
G-SM761LH-48N

480
120/208/240/277
480
120/208/240/277
480
120/208/240/277
480
120/208/240/277
480

With Ballast for 1500 W Metal Halide Lamp
II

20.2° x 21.1°

52,950

34.2%

1,877,349

2,180,356

III

45.1° x 45.1°

77,646

50.1%

679,149

899,846

IV

58.6° x 59.3°

86,746

56.0%

300,526

374,996

V

73.6° x 74.0°

94,188

60.8%

181,522

226,386

VI

111.5° x 111.2°

104,301

67.3%

107,161

116,057

120/208/240/277
480
120/208/240/277
480
120/208/240/277
480
120/208/240/277
480
120/208/240/277
480

Lighting: General Lighting — Area — Floodlights

With Ballast for 400 W Pulse Start Metal Halide Lamp
II

20.9° x 20.1°

14,538

36.3%

345,368

528,021

V

73.1° x 72.8°

19,566

48.9%

35,090

54,015

VI

108.4° x 99.1°

22,656

66.6%

28,815

34,043

480
120/208/240/277

With Ballast for 1000 W High Pressure Sodium Lamp
V

69.1° x 65.2°

63,710

45.5%

175,347

302,942

VI

110.3° x 104.6°

81,722

58.4%

81,998

107,556

480
120/208/240/277
480

With Ballast for 400 W High Pressure Sodium Lamp
II
III
IV
V
VI

Lighting

120/208/240/277

120/208/240/277
480
120/208/240/277
480
120/208/240/277
480
120/208/240/277
480
120/208/240/277
480

➊ For tri-tap 120/277/347 V, change suffix -MTN to -TTN V.

1384

Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

Beam-Master™ Floodlights
General Purpose and Heavy Duty.

Ballast for 400 W PSMH; 1000 W, 1500 W MH; 400 W, 1000 W HPS.

Mounting Fittings and Accessories

Dimensions

Dimensions

Description

Catalog Number

Crossarm Mounting Bracket
5.0"/
127.0 mm

4.44"/
112.8 mm

G-AM-8-CA

Slip-fits 2” or 2-1/2”/50.8 or 63.5 mm
poletop tenons. Includes floodlight yoke
bolts, 3 locking bolts and cord grip.

G-AM-8-SF

22.88"/581.2 mm

2.31"/
58.7 mm

24.00"/609.6 mm
21.00"/533.4 mm

180° horizontal adjustment—	
degree-marked. Facilitates mounting
floodlight to crossarm or other flat 	
surface, or to G-AM-8-WB. Includes
floodlight yoke bolts.

Poletop Slip-Fitter
3.5"/
88.9 mm

4.5"/
114.3 mm
6.0"/127.0 mm

4.0"/101.6 mm

Pipe or Wall Mount Bracket
4.88"/
124.0 mm

5.0"/
127.0 mm

3.0"/
76.2 mm
5.5"/139.7 mm
4.5"/
114.3 mm

Used with G-AM-8-CA. Clamps to 1”  
to 2”/25.4 to 50.8 mm pipe, vertical or
horizontal, or mounts on flat surfaces.
Includes U-bolt and crossarm bracket
bolts.

G-AM-8-WB

Fuse and Cartridge

10 Amp.

G-F10

20 Amp

G-F20

Electrical Specifications
400 W
Line
Volts

Start

Oper.

Metal Halide — C.W.A. ➋ Ballast Amps
1000 W
Total
Total
Watts
Start
Oper.
Watts
Start

1500 W
Oper.

Total
Watts

High Pressure Sodium — C.W.A. ➋ Ballast Amps
400 W
1000 W
Total
Total
Start
Oper.
Watts
Start
Oper.
Watts

120

3.25

4.00

458

8.0

9.20

1080

13.50

14.0

1610

3.30

3.80

465

6.35

9.50

1100

208

1.90

2.30

458

4.6

5.30

1080

7.70

8.00

1610

1.80

2.20

465

3.80

5.50

1100

240

1.90

2.00

458

4.0

4.60

1080

6.70

7.00

1610

1.60

1.90

465

3.20

4.80

1100

277

1.40

1.75

458

3.50

4.00

1080

5.90

6.00

1610

1.40

1.70

465

2.75

4.20

1100

480

.85

1.00

465

2.00

2.30

1080

2.25

3.50

1610

.80

1.00

465

1.80

2.45

1100

Lighting

➋ C.W.A.—Constant Wattage Autotransformer.
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

Lighting: General Lighting — Area — Floodlights

Cartridges are furnished complete with
two 10”/254 mm-long high temperature
wire leads and 600 Volt fuse.

1385

Wallmaster™ HPS/PSMH Luminaires

Lighting: General Lighting — Area — Architectural

Lighting

Vertical and Horizontal Wall Mount
50 W, 75 W, 100 W, 150 W HPS; 70 W, 100 W PSMH.

Applications
•	 Totally enclosed luminaires for public security installations.
Tough polycarbonate refractor provides vandal resistance.
•	 Ideal where illumination over wide areas adjacent to walls
is required. Applications include walkways, parking lots
and garages, building exteriors, shopping centers, stores,
restaurants, tunnels, underpasses, loading docks, ramps,
security lighting areas, entrances and recreational areas.

Features
•	 Computer designed optical system. Reflector provides optimum
down and out light distribution. Prismatic refractor provides soft
light with even distribution, reducing glare.
•	 Contemporary architectural design with attractive bronze
polyester finish. Soft, diffused light enhances the beauty of any
architectural setting.
•	 Enclosed and gasketed for use in wet locations—indoors and
out. High temperature neoprene gasketing.
•	 Easy to maintain. Hinged lens frame swings open (just loosen
two captive bolts) for fast, easy relamping and access to
internal components.
•	 Quick, easy installation. Fixture bolts to any flat surface or
any standard 3” or 4”/76.2 or 101.6 mm outlet box for vertical
mounting.
•	 High energy efficiency. High pressure sodium lamps use 	
approximately one-fourth as much electrical energy as
incandescent lamps.
•	 Pre-wired, integrally ballasted.
•	 Complete assemblies available with a choice of ballasts: high
reactance high power factor—with or without photocontrol
(automatic ON–OFF operation). High power factor ballasts
provide a minimum 90% P.F. and are suitable for use in high
ambient temperature areas. High reactance high power factor
ballasts are single-tap (120 or 480 Vac), dual tap (120/277 Vac)
and multi-tap (120-277 Vac). Reactor and reactor high power
factor ballasts are 120 Vac.
•	 Glass thermal barrier in 100 W and 150 W units protects
polycarbonate lens from heat for longer lens life.
•	 Tough, molded polycarbonate refractor provides cool fixture
operation.
•	 Three knockouts provided for conduit and wiring.
•	 Medium base porcelain socket with spring loaded nickel plated
contacts.

Standard Materials
•	 Ballast housing and wall bracket: aluminum
•	 Hinged lens assembly: high Impact, non-solarizing,
polycarbonate
•	 Reflector: aluminum

Dimensions
18.0"/
457.2 mm
9.81"/
249.2 mm

4.88"/
124.0 mm

6.38"/
162.1 mm
15.13"/
384.3 mm
.49 Sq.Ft./0.05 Sq. M
.51 Sq.Ft./0.05 Sq. M

2.88"/
73.2 mm

6.88"/
174.8 mm

Certifications and Compliances
•	 UL Standard: E85142
•	 UL Standard: 1598
•	 CSA Certified: LR9349

Standard Finishes
•	 Ballast housing, wall bracket: two-coat bronze polyester finish
•	 Reflector: natural finish

Options
•	 Photocontrol provides automatic ON-OFF operation. Order
luminaires with -PC suffix or add -PC suffix to any 120 Volt
luminaire catalog numbers.

† For multi-tap ballast specify voltage to be used.

1386

Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

Wallmaster™ HPS/PSMH Luminaires
Vertical and Horizontal Wall Mount

Line Voltage

Vertical Mount

Catalog Number
Horizontal Mount

Vertical Mount V

50-Watt High Pressure Sodium
Reactor Ballast 

120 V

G-WM130L-12R

G-WM134L-12R

G-WMM50L-R1 V

Reactor Ballast, High Power Factor 

120 V

G-WM130L-12RH

G-WM134L-12RH

G-WMM50L-H1 V

70-Watt High Pressure Sodium
High Reactance Ballast, High Power Factor

120/208/240/277 V

G-WM230L-MT

G-WM234L-MT

G-WMM70L-MT V

High Reactance Ballast, High Power Factor

480 V

G-WM230L-48

G-WM234L-48

Not Available

Reactor Ballast 

120 V

G-WM230L-12R

G-WM234L-12R

G-WMM70L-R1 V

Reactor Ballast, High Power Factor 

120 V

G-WM230L-12RH

G-WM234L-12RH

G-WMM70L-H1 V

100-Watt High Pressure Sodium
High Reactance Ballast, High Power Factor

120/208/240/277 V

G-WM330L-MT

G-WM334L-MT

G-WMM10L-MT V

High Reactance Ballast, High Power Factor

480 V

G-WM330L-48

G-WM334L-48

Not Available

Reactor Ballast 

120 V

G-WM330L-12R

G-WM334L-12R

G-WMM10L-R1 V

Reactor Ballast, High Power Factor 

120 V

G-WM330L-12RH

G-WM334L-12RH

G-WMM10L-H1 V

G-WM430L-MT

G-WM434L-MT

Not Available

150-Watt High Pressure Sodium
High Reactance Ballast, High Power Factor

120/208/240/277 V

High Reactance Ballast, High Power Factor

480 V

Not Available

Not Available

Not Available

Reactor Ballast 

120 V

G-WM430L-12R

G-WM434L-12R

G-WMM15L-R1 V

Reactor Ballast, High Power Factor 

120 V

G-WM430L-12RH

G-WM434L-12RH

G-WMM15L-H1 V

120/208/240/277 V

G-WM230H-MT

G-WM234H-MT

G-WMM70H-MT V

120/208/240/277 V

G-WM330H-MT

G-WM334H-MT

G-WMM10H-MT V

70-Watt Pulse Start Metal Halide
High Reactance Ballast, High Power Factor
100-Watt Pulse Start Metal Halide
High Reactance Ballast, High Power Factor

Wall Mounting Kit
Dimensions

Description

Catalog Number

4.88"/
124.0 mm

Adapts vertical mount fixtures to horizontal
position.

G-WM-HMK

2.88"/
73.2 mm

 Add suffix -PC for Photocontrol. Provides automatic dusk-to-dawn ON-OFF operation. Specify voltage to be used with photocell, if used with multi voltage
ballast.
 Change the -MT suffix to -TT for tri-tap 120/277/347 V V.
V CSA Certification only.
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

1387

Lighting: General Lighting — Area — Architectural

Description

Lighting

50 W, 75 W, 100 W, 150 W HPS; 70 W, 100 W PSMH.

Wallmaster™ HPS/PSMH Luminaire Electrical Specifications

Lighting: General Lighting — Area — Architectural

Lighting

Vertical and Horizontal Wall Mount
50 W, 75 W, 100 W, 150 W HPS; 70 W, 100 W PSMH.

Line Voltage

Type of Ballast

Starting Amps

Operating Amps

Total Watts

50-Watt High Pressure Sodium
120

Reactor

1.80

1.18

60

120

Reactor, High Power Factor

0.75

0.55

60

70-Watt High Pressure Sodium
120/208/240/277

High Reactance, High Power Factor

0.75/0.35

0.81/0.35

91

480

High Reactance, High Power Factor

0.21

0.21

94

120

Reactor

2.25

1.70

87

120

Reactor, High Power Factor

0.85

0.75

82

100-Watt High Pressure Sodium
120/208/240/277

High Reactance, High Power Factor

1.30/.60

1.15/0.50

130

480

High Reactance, High Power Factor

0.33

0.31

135

120

Reactor

3.05

2.40

115

120

Reactor, High Power Factor

1.50

1.05

115

High Reactance, High Power Factor

2.00/0.85

1.65/.72

188

150-Watt High Pressure Sodium
120/208/240/277
480

High Reactance, High Power Factor

0.50

0.47

189

120

Reactor

4.55

3.40

170

120

Reactor, High Power Factor

2.20

1.50

170

0.80/0.39

0.85/0.39

95

1.22/0.44

1.15/0.50

128

70-Watt Pulse Start Metal Halide
120/208/240/277

High Reactance, High Power Factor

100-Watt Pulse Start Metal Halide
120/208/240/277

1388

Constant Wattage Auto transformer (CWA)

Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

Wallmaster™ HPS/PSMH Luminaire Photometric Data *
Vertical and Horizontal Wall Mount

Lighting

50 W, 75 W, 100 W, 150 W HPS; 70 W, 100 W PSMH. Data Based on 70 Watt, HPS Clear B-17 Medium Base Lamp (6,300 lumens).

Lighting: General Lighting — Area — Architectural

Typical Footcandle Values
70 W High Pressure Sodium

Ft. Candles for Iso-Footcandle Lines
Mtg. Ht.

A

B

C

E

F

6'

5.80

4.80

3.87

2.88

D

1.94

0.96

0.39

G

7'

4.22

3.54

2.84

2.14

1.42

0.70

0.29

8'

3.26

2.72

2.17

1.63

1.09

0.54

0.22

10'

2.09

1.73

1.39

1.04

0.70

0.34

0.14

12'

1.45

1.21

0.96

0.72

0.48

0.24

0.10

14'

1.06

0.89

0.71

0.53

0.36

0.18

0.07

Watts

Lumens

Mult.

35

2,250

.357

50

3,500

.556

100

9,500

1.508

150

16,000

2.540
NOTE: For other HPS, Clear, Med. Base Lamps multiply
all footcandle values as follows:

◊ Distance in terms of mounting height (i.e., ratio) of distance to height. Example: @ 15 foot/4.6 meters mounting height, 1 means 15 foot/4.6 meters; 2 means
30 foot/9.1 meters, etc.)
* Additional photometric charts available on request.
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

1389

Wallmaster 400 HPS/PSMH Luminaires
™

Lighting: General Lighting — Area — Architectural

Lighting

Horizontal Lamps Suitable for Wet Locations
400 W, 250 W, 175 W PSMH; 400 W, 250 W HPS. Mogul Base.

Applications
•	 Ideal where illumination over wide areas adjacent to walls is
required. Applications include:
	 — Walkways
	 — Parking lots
	 — Garages
	 — Building exteriors
	 — Shopping centers
	 — Stores
	 — Restaurants
	 — Tunnels
	 — Underpasses
	 — Loading docks
	 — Ramps
	 — Security lighting areas
	 — Entrances
	 — Recreational areas

Features
•	 Enclosed and gasketed for use in outdoor wet locations.
•	 Specular anodized aluminum reflector provides efficient light
projection.
•	 High transmittance, non-yellowing borosilicate glass refractor
for superior photometrics.
•	 Field adjustable bracket permits easy adjustment of beam
angle.
•	 Quick, easy installation. Back plates permit alignment with
virtually all standard recessed junction boxes.
•	 Prewired, integrally ballasted. Housing is designed for heavy
duty use and coated with bronze polyester powder to optimize
protection against chipping and fading.
•	 Stainless steel aircraft cable connects lens assembly to
mounting plate freeing both hands for servicing and installation.
•	 3 tapped holes (1/2”/12.7 mm NPS standard) – one on each
side and one on the top.  May be used for conduit or optional
photocontrol.
•	 All ballasts are high power factor, CWA type.

Standard Materials
•	 Ballast housing: die cast copperfree (4/10 of 1% max.)
aluminum
•	 Refractor: heat and shock resistant, non-yellowing borosilicate
glass
•	 Refractor to housing joint: liquid silicone rubber
•	 Gasket (between lens assembly and mounting plate): neoprene
•	 Lamp socket: glazed porcelain

Standard Finishes
•	 Ballast housing: bronze polyester finish

Options
•	
•	
•	
•	

Stainless steel wire guard to protect fixture.
Lexan® shields for added protection.
Photocontrol for automatic ON/OFF operation.
Fusing to provide overcurrent protection.

Certifications and Compliances
•	 UL Listed: E85142
•	 UL Standard:1598
•	 CSA Certified: LR9349

1390

Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

Wallmaster 400 HPS/PSMH Luminaires
™

Horizontal Lamps Suitable for Wet Locations

Lighting

400 W, 250 W, 175 W PSMH; 400 W, 250 W HPS. Mogul Base.

Weight Lbs./
Kgs ➊

Catalog
Number

175 Watt Metal Halide
CWA Ballast, High Power Factor

120-277

17/7.7

G-WM530P-MT ➋

CWA Ballast, High Power Factor

480

17/7.7

G-WM530P-48 ➋

CWA Ballast, High Power Factor

120-277

24/10.9

G-WM630P-MT ➋

CWA Ballast, High Power Factor

480

24/10.9

G-WM630P-48 ➋

CWA Ballast, High Power Factor

120-277

38/17.2

G-WM730P-MT ➋

CWA Ballast, High Power Factor

480

38/17.2

G-WM730P-48 ➋

CWA Ballast, High Power Factor

120-277

41/18.6

G-WM630L-MT ➋

CWA Ballast, High Power Factor

480

41/18.6

G-WM630L-48 ➋

CWA Ballast, High Power Factor

120-277

45/20.4

G-WM730L-MT ➋

CWA Ballast, High Power Factor

480

45/20.4

G-WM730L-48 ➋

250 Watt Pulse Start Metal Halide

400 Watt Pulse Start Metal Halide

250 Watt High Pressure Sodium

400 Watt High Pressure Sodium

Dimensions

MH
12.25"/
12-1/4"
311.2 mm

PSMH, HS
7.25"/
7-1/4"
184.2 mm

9.5"/
9-1/2"
241.3
mm

17.0"/
431.8 mm

14.0"/
355.6 mm

9.5"/
241.3 mm

➊ All weights are approximate.
➋ Use supply wire rated 302 °F/150 °C.
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

1391

Lighting: General Lighting — Area — Architectural

Line
Voltage

Description

Wallmaster 400 HPS/PSMH Luminaire Accessories
™

Lighting: General Lighting — Area — Architectural

Lighting

Horizontal Lamps Suitable for Wet Locations
400 W, 250 W, 175 W PSMH; 400 W, 250 W HPS. Mogul Base.

Description

Weight Lbs./Kgs ➊

Catalog Number

0.1/.05

G-FH2

Fuse Kit
2 Amp
3 Amp

0.1/.05

G-FH3

5 Amp

0.1/.05

G-FH5

6 Amp

0.1/.05

G-FH6

8 Amp

0.1/.05

G-FH8

10 Amp

0.1/.05

G-FH10

For use with 175 Watt Metal Halide

1.2/0.54

G-WM5G

For use with 250 – 400 Watt Metal Halide
and High Pressure Sodium

1.3/0.59

G-WM7G

Stainless Steel Guard

Lexan® Shield
For use with 175 Watt Metal Halide

1.0/0.45

G-WM5VS

For use with 250 – 400 Watt Metal Halide
and High Pressure Sodium

1.5/0.68

G-WM7VS

120 Volt (1900 VA)

0.3/0.14

G-WMPC120

208-277 Volt (1900 VA)

0.3/0.14

G-WMPC208

480 Volt (1900 VA)

0.3/0.14

G-WMPC480

Lens / Cover Assembly for 175 Watt Units

6.5/2.95

G-WM5CA

Lens / Cover Assembly for 250 – 400 Watt Units

11.3/5.13

G-WM7CA

Mogul Base Lampholder

0.5/0.23

G-WMRS

Photocontrols

Replacement Parts

➊ All weights are approximate

1392

Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

Wallmaster 400 HPS/PSMH Luminaire Photometric Data
™

Horizontal Lamps Suitable for Wet Locations

Lumens:
Mounting Height:

400 Watt Pulse Start Metal Halide	
Clear, BT-37
34000
20 Feet

RATIO: LATERAL DISTANCE / MOUNTING HEIGHT

0

5

1

400 Watt Metal Halide

2
2

CONVERSION TABLE
for different mounting heights
15’

1.78

30’

.44

20’

1.00

35’

.33

25’

.64

40’

.25

G-WM630P
Lumens:
Mounting Height:

3
.2
4

250 Watt Pulse Start Metal Halide	
Clear, BT-28
19500
15 Feet

3

2

1

0

1

2

3

RATIO: LATERAL DISTANCE / MOUNTING HEIGHT

0

5
1
2

CONVERSION TABLE
for different mounting heights

1

2

10’

2.25

20’

.56

15’

1.00

25’

.36

.5
3
.2
4

G-WM530P
Lamp:

2

1

1

16’

.39

10’

1.00

18’

.30

3

12’

.83

20’

.25

4

14’

.51

2
1
.5
.25

5
2

3

400 Watt High Pressure Sodium	
Clear, E18
50000
20 Feet

1

.44

20’

1.00

35’

.33

25’

.64

40’

.25

0

1

1

2

10
5

1

2

2

1

3

3
4

2

5

.5

.5

4

.25

.2

5

5

3

3

2

2

1

1
0

1

0

2

1

RATIO: LONGITUDINAL DISTANCE / MTG. HGT.

30’

RATIO: LONGITUDINAL DISTANCE / MTG. HGT.

1.78

3

2

1

0

1

RATIO: LATERAL
DISTANCE
/ MOUNTING
RATIO: LATERAL
DISTANCE
/ MOUNTING
HEIGHT HEIGHT
0

CONVERSION TABLE
for different mounting heights
15’

3

5

2

1.56

Lumens:
Mounting Height:

2

0

8’

Lamp:

1

1

CONVERSION TABLE
for different mounting heights

G-WM730L

0

RATIO: LATERAL DISTANCE / MOUNTING HEIGHT

RATIO: LONGITUDINAL DISTANCE / MTG. HGT.

Lumens:
Mounting Height:

3

175 Watt Pulse Start Metal Halide	
Coated, BT-28	
(in middle position)
12000
10 Feet

RATIO: LONGITUDINAL DISTANCE / MTG. HGT.

Lamp:

1
.5

RATIO: LONGITUDINAL DISTANCE / MTG. HGT.

Lamp:

Lighting: General Lighting — Area — Architectural

G-WM730P

Lighting

400 W, 250 W, 175 W PSMH; 400 W, 250 W HPS. Mogul Base.

3

2

3

1393

Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
RATIO: LATERAL DISTANCE / MOUNTING HEIGHT
0
RAT

Wallmaster 400 HPS/MH Luminaires Photometric Data
™

400 W, 250 W, 175 W PSMH; 400 W, 250 W HPS. Mogul Base.

G-WM630L
Lamp:

Lumens:
Mounting Height:

250 Watt High	
Pressure Sodium	
Clear, E-18
27500
20 Feet

RATIO: LATERAL DISTANCE / MOUNTING HEIGHT
0
5

1

2
2

1
.5

3

.2

4
3

2

1

0

1

2

3

Fusing For Wallmaster™ 400

Lamp Watts

175 W

250 W

400 W

1394

Volts
120
208
240
277
480
120
208
240
277
480
120
208
240
277
480

1
Ballast Amps
High Pressure Sodium (CWA)
Pulse Start Metal Halide (CWA)
Rating
Start
Oper.
Rating
Start
Oper. 2
—
—
—
5A
.90
1.78
—
—
—
3A
.50
1.08 3
—
—
—
3A
.35
.89
—
—
—
2A
.30
.76 4
—
—
—
2A
.25
.50
8A
2.00
2.50
8A
1.90
2.50
5A
1.20
1.50
5A
1.10
1.45
5A
1.00
1.30
5A
.96
1.25
3A
.85
1.10
3A
.85
1.10
3A
.40
.65
3A
.45
.60
10A
3.30
3.80
10A
3.50
4.00
8A
1.80
2.20
6A
2.00
2.30
5A
1.60
1.90
5A
1.75
2.00
5A
1.40
1.70
5A
1.50
1.75
5A
.80
1.00
5A
.90
1.00

5

Fuse Catalog Number

3

Fuse
Qty. Req.
1
2
2
1
2
2 1
1
2
2
1
2
1
2
2
1
2

2

HPS
(CWA)
—
.5
—
—
.2
—
0
1
—
G-FH8
G-FH5
G-FH5
G-FH3
G-FH3
G-FH10
G-FH8
G-FH5
G-FH5
G-FH5
1

2

3

RATIO: LONGITUDINAL DISTANCE / MTG. HGT.

RATIO: LATERAL DISTANCE / MOUNTING HEIGHT
0

RATIO: LONGITUDINAL DISTANCE / MTG. HGT.

Lighting: General Lighting — Area — Architectural

Lighting

Horizontal Lamps Suitable for Wet Locations

PSMH
(CWA)
G-FH5
G-FH3
G-FH3
G-FH2
G-FH2
G-FH8
G-FH5
G-FH5
G-FH3
G-FH3
G-FH10
G-FH6
G-FH5
G-FH5
G-FH5

Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

Areamaster Squarelite™ 400 Sharp Cutoff Luminaires
Integrally Ballasted. For Double-Ended, Tubular 400 W HPS.

Lighting

Lighting: General Lighting — Area — Architectural

Applications
•	 Powerful, efficient lighting for areas such as parking lots,
shopping centers, building exteriors, sports areas, security
lighting and industrial process lighting.
•	 Ideal where controlled light distribution over medium or large
size areas is required. Delivers light only where it is needed with
virtually no glare.
•	 Enclosed and gasketed, Suitable for use in wet locations.

Features
•	 A single luminaire efficiently projects light in a rectangular
pattern-the shape of most areas to be lighted. A cluster of four
pole-mounted luminaires casts light in a nearly perfect square.
Ideal for such areas as parking lots, shopping centers and
sports areas.
•	 Utilizes a specially developed, small, double-ended tubular
lamp in combination with a unique precision reflector. The
design of the reflector together with the precise positioning of
the arc tube provides exceptionally accurate control of the light
distribution.
•	 Projects optimum light levels over medium and large size areas
with virtually no wasted light. A single, horizontally mounted 400
Watt luminaire provides 36,350 candlepower at 51 with a sharp
cutoff at 66° (62° at front and 4° at back of luminaire) with a
horizontal cutoff (sideways ) at 101°.
•	 Sharp cutoff confines light to specific property zones No spilling
of light on neighboring properties.
•	 Even light distribution at a 4-to-1 spacing-to-pole-height ratio.
•	 Virtually no glare. The lamp is deeply recessed within the
reflector to eliminate visually uncomfortable glare.
•	 Compact in size, attractively styled contemporary design,
rugged and dependable.
•	 A wide range of ballasts and voltages are available for both
domestic and export applications.
•	 Integral ballast.
•	 Mounting Choice:
(1) Trunnion mount, zinc plated steel trunnion with architectural
bronze polyester finish
(2) Integral slip-fitter mount. Built-in slip-fitter for internal wiring.
Adjustable laterally and vertically, slip-fits 2” or 2-1/2”/50.8 or
63.5 mm  pipe. Architectural bronze polyester finish
(3) Davit Mount. Bolts to square pole-topfitter. Up to four
luminaries may be clustered on each pole fitter

Illustrated Features

Unique reflector design projects light at wide angle with sharp cutoff.
Projected Area: 1.2 Sq. Ft./0.11 Sq. M.

Standard Materials
•	
•	
•	
•	
•	
•	

Reflector: aluminum
Lens: thermal shock and impact resistant glass
Gasket: silicone rubber
Housing: aluminum
Lens door: aluminum
Hex head bolts: 4 — 1/4"/6.4 mm dia. captive stainless steel

Standard Finishes
•	 Reflector: natural finish
•	 Housing, mounting and lens door: architectural bronze polyester
finish

Certifications and Compliances
•	 UL Listed: E85142
•	 UL Standard: 1598
•	 CSA Certified: LR9349

Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

With Areamaster Squarelite, a single horizontally mounted
(for low glare) luminaire projects light at a wide angle with sharp
cutoff-ideal for medium and large size areas such as
parking lots, shopping centers and sports areas.
Electrical Specifications
Line Volts
120
208
240
277
347
480

High Pressure Sodium — C.W.A. Ballast Amps — 400 W
Start
Oper.
Total Watts
3.30
3.80
465
1.80
2.20
465
1.60
1.90
465
1.40
1.70
465
1.00
1.32
465
0.80
1.00
465

1395

Areamaster Squarelite™ 400 Sharp Cutoff Luminaires

Lighting: General Lighting — Area — Architectural

Lighting

Integrally Ballasted. For Double-Ended, Tubular 400 W HPS.

Description

LIne Voltage

Catalog Number ➊

Davit Mount
120/208/240/277
Bolts to Square Poletop Filter
(Cat No. G-SCDA) or Wall
Bracket (Cat. No. G-SWD-1
below.

G-SC776L-MT-L ➋

480

G-SC776L-48-L

120/208/240/277

G-SC776L-MT ➋

480

G-SC776L-48

Integral Slip-Fitter Mount
120/208/240/277
Slip-fits on any 2”/50.8 mm or
2-1/2”/63.5 mm pipe size poletop
tenons.

G-SC775L-MT-L ➋

480

G-SC775L-48-L

120/208/240/277

G-SC775L-MT ➋

480

G-SC775L-48

Trunnion Mount
120/208/240/277
May be used with Poletop 	
slip-fitter or crossarm accessory

G-SC771L-MT-L ➋

480

G-SC771L-48-L

120/208/240/277

G-SC771L-MT ➋

480

G-SC771L-48

Square Poletop Fitter for Davit Mount

Slips onto 2”/50.8 mm poletop tenons. 	
Accommodates up to four Davit Mount
luminaires.

G-SCDA

Secured to wall with four bolts. 	
Davit mount is bolted to this bracket.

G-SWD-1

UV stabilized polycarbonate, with installation
hardware and instructions.

G-AM-6-VS

For NEMA type photocontrol, with installation
hardware, instructions.

G-1PCR

Wall Bracket for Davit Mount

Vandal Shield for Luminaire

Photocontrol Receptacle

➊ Lamp furnished with fixture on catalog numbers with Suffix -L: HPS tubular 400 W T-7, 46,000 lumens (LU400/T7).
➋ Change the -MT suffix to -TT for tri-tap 120/277/347 V V.

1396

Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

Areamaster Squarelite™ 400 Sharp Pole Data
Integrally Ballasted. For Double-Ended, Tubular 400 W HPS.

Lighting

Lighting: General Lighting — Area — Architectural

Application
•	 To mount single or multiple luminaires at heights of 20 to 40
feet/ 6.1 to 12.2 meters.

4.0"/
101.6 mm

Features

T

4.0"/
101.6 mm

•	 2”/50.8 mm pipe size tenon accepts a single luminaire, or 2, 3
or 4 luminaires with appropriate poletop bracket.
•	 High-strength shafts are made from square steel structural tube
with minimum yield strength of 46,000 psi.
•	 Base plates are of structural quality hot-rolled steel with
minimum yield strength of 36,000 psi. Anchor base telescopes
the pole shaft and is welded around top and bottom.
•	 A 3” x 5”/76.2 x 127 mm reinforced handhole with cover and
grounding lug 14”/355.6 mm above the pole base is standard.
•	 Anchor bolts are furnished complete with two hex nuts and
washers, and are of 55,000 psi steel.
•	 Poles are designed to withstand dead loads and theoretical
dynamic loads developed by sustained winds of 80 mph/128
kph with an appropriate gust factor. The weights and EPA
include luminaires and/or mounting adapters, and their effective
projected area is considered to be the product of 	
the actual projected area and the drag coefficient. Pennants,
signs, and similar elements that create additional stress on
poles should not be used without prior factory approval.

2”/50.8 mm
Pipe Size Tenon
(2-3/8”/
60.5 mm O.D.)

14.0"/
355.6 mm

Square Steel Poles for Davit Mount Luminaires
Dimensions may vary. Consult your local sales representative for specifications
Mtg. Ht.
Feet/Meters
A

Shaft Size
Inches/ Millimeters

Bolt Circle
in/mm
BC

Base Thickness
in/mm
T

Anchor Bolt
Dia. x Lgth.
in/mm

Max. Proj.
Area
Sq.Ft./Sq.M. ➊

Catalog Number ➌

20/6.1

4” x 4” x 11Ga./
101.6 x 101.6 x 11Ga

➋

.75/19.1

.75 x 20/
19.1 x 508

9.0/0.84

G-PSSL-20EPX

25/7.6

4” x 4” x 11Ga.
101.6 x 101.6 x 11Ga.

➋

.75/19.1

.75 x 20/
19.1 x 508

4.1/0.38

G-PSSL-25EPX

30/9.1

5” x 5” x 11Ga.
127 x 127x 11Ga

➋

1.0/25.4

.25 x 20/
25.4 x 508

4.2/0.39

G-PSSL-30EPX

35/10.7

5” x 5” x 7Ga.
127 x 127 x 7Ga

➋

1.0/25.4

1 x 40/
25.4 x 1016

6.1/0.57

G-PSSM-35EPX

39/11.9

6” x 6” x 7Ga.
152.4 x 152.4 x 7Ga.

➋

1.0/25.4

1 x 40
25.4 x 1016

7.8/0.72

G-PSSH-39EPX

➊ Calculated for winds of 80 MPH/128 KPH.
➋ Dimensions may vary- Consult your local sales representative for specifications.
➌ Square steel poles are furnished with anchor bolts and nuts, and 2-3/8”/60.5 mm O.D. x 4”/101.6 mm tenon, finished with bronzetone enamel and
cardboard wrapped. Touch-up paint furnished with every shipment.
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

1397

Areamaster Squarelite™ 400 Sharp Cutoff Luminaire Photometric Data

This report has been prepared in accordance with IES guides on testing
procedures. It is representative of luminaires tested under standardized and
stabilized laboratory conditions. Various operating factors can cause differences
between laboratory data and actual field performance.

Distance (ft)
Ahead/Behind
Footcandle
165
160
155
150
145
140
135
130
125
120
115
110
105
100
95
90
85
80
75
70
65
60
55

30
—
—
—
—
—
—
—
—
—
—
—
.01
.01
.02
.03
.05
.07
.10
.14
.23
.55
1.06
1.85

40
—
—
—
—
—
.01
.01
.01
.02
.03
.04
.05
.06
.08
.10
.21
.37
.60
.91
1.35
1.91
2.53
3.39

50
.01
.01
.01
.02
.02
.03
.03
.04
.05
.06
.10
.17
.26
.38
.54
.74
1.00
1.29
1.62
2.05
2.69
9.07
3.17

60
.02
.03
.03
.04
.04
.06
.09
.14
.20
.27
.35
.46
.60
.77
.93
1.13
1.37
1.66
2.02
2.16
2.21
2.21
2.18

50

3.08

4.55

3.19

2.34

45

4.51

4.93

3.16

2.24

40
35
30
25
20
15
10
5
0
-5
-10
-15
-20
-25
-30

6.64
8.65
8.85
8.95
9.25
11.4
13.7
12.7
6.58
1.15
.60
.77
1.13
1.11
.85

4.98
4.98
5.04
5.49
6.41
7.47
7.67
6.53
3.70
.81
.40
.31
.43
.59
.70

3.23
3.18
3.63
4.10
4.64
4.95
4.83
3.93
2.37
.58
.33
.23
.21
.26
.35

2.31
2.57
2.85
3.16
3.43
3.41
3.18
2.60
1.65
.48
.29
.18
.15
.15
.19

Mounting Height (Feet)

Distance in terms of mounting height ◊

Lighting: General Lighting — Area — Architectural

Lighting

Integrally Ballasted. For Double-Ended, Tubular 400 W HPS.
Photometric Number TSC2001-S2 Sharp Cutoff 400 W HPS Luminaire G-SC776L-MT. (HPS 400 W LU400/T7, 46,000 lumens).

Distance in terms of mounting height ◊

400W HPS
Mtg.
Ht.
20
25
30
35
40
45

Ft. Candles for Iso-Footcandle Lines
A
29.03
18.58
12.90
9.48
7.26
5.73

B
20.21
12.91
8.98
6.60
5.05
4.00

C
19.19
12.28
8.53
6.27
4.80
3.79

D
8.07
5.16
3.59
2.63
2.02
1.59

E
2.39
1.53
1.06
.78
.60
.47

F
.39
.25
.17
.13
.10
.08

G
.17
.11
.08
.06
.04
.03

H
.04
.04
.03
.02
.02
.01

◊ Distance in terms of mounting height (i.e., ratio) of distance to height. Example: @ 15 foot/4.6 meters mounting height, 1 means 15 foot/4.6 meters; 2 means
30 foot/9.1 meters, etc.)
* Additional photometric charts available on request.

1398

Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

Round Tapered Steel Poles

Applications
•	 To mount single or multiple luminaires to heights from 20 to 39
feet/6.1 to 11.9 meters.

Features

Lighting

4.0"/
101.6 mm

•	 2”/50.8 mm pipe size tenon accepts a single luminaire, or 2, 3,
or 4 luminaires with appropriate pole-top mounting bracket.
•	 Shafts are tapered, one-section 	
design of 11 gauge commercial quality steel with a minimum
yield strength of 55,000 psi after fabrication.
•	 Base plates are of structural quality hot-rolled steel with
guaranteed minimum yield strength of 36,000 psi.
•	 A 4” x 6-1/2”/101.6 x 165.1 mm reinforced handhole with
cover and grounding lug 14”/55.6 mm above the pole base is
standard.
•	 Anchor bolts are furnished complete with nuts and washers,
and are of 55,000 psi steel.

2"/50.8 mm
Pipe Size Tenon
(2-3/8"/60.5 mm O.D)

Lighting: General Lighting — Area — Poles and Hangers

Standard Finishes
•	 Poles are finished with red-oxide prime-paint after fabrication

Options
•	 For bronze powder coat finish (to match Appleton fixtures) add
Suffix -EPX.
•	 For galvanized finish add -GAL.

14.0"/
355.6 mm

Dimensions may vary. Consult your local sales representative for specifications
Mounting
Height
Ft/M
A

Shaft Size ➋

Base Size
In/mm
S➊

Bolt Circle
In/mm
BC

Base
Thickness
In/mm
T➊

Bolt Proj.
In/mm
P➊

Tube
Diameter
In/mm
D

Anchor Bolt
Dia. x Lgth.
In/mm

Max.
Proj Area
Sq.Ft./Sq.M.➌

Catalog
Number ➍

20/6.1

6.5 x 3.7 x 20’/
165.1 x 94.0 x 6.1

10.0/254.0

➊

1.0/25.4

2.25/57.2

6.5/165.1

1 x 40/
25.4 x 1016

18.7/1.74

G-PRTH-20

25/7.6

7.0 x 3.5 x 25’/
177.8 x 88.9 x 7.6

10.5/266.7

➊

1.0/25.4

2.25/57.2

7.0/177.8

1 x 40
25.4 x 1016

14.4/1.34

G-PRTH-25

30/9.1

8.0 x 3.8 x 30’/
203.2 x 96.5 x 9.1

11.5/292.1

➊

1.0/25.4

2.25/57.2

8.0/203.2

1 x 40
25.4 x 1016

14.5/1.35

G-PRTH-30

35/10.7

8.5 x 3.6 x 35’/
215.9 x 91.4 x 10.7

12.0/304.8

➊

1.0/25.4

2.25/57.2

8.5/215.9

1 x 40
25.4 x 1016

12.6/1.17

G-PRTH-35

39/11.9

9.0 x 3.5 x 39’/
228.6 x 88.9 x 11.9

13.0/330.2

➊

1.0/25.4

2.25/57.2

9.0/228.6

1 x 40
25.4 x 1016

11.7/1.09

G-PRTH-39

➊ Dimensions may vary—Consult your local sales representative for specifications.
➋ Shaft bottom (In. Dia./MM. Dia) x shaft top (In. Dia./MM.Dia.) x shaft length to tenon.
➌ Calculated for winds of 100 MPH/160 KPH.
➍ Anchor bolts and nuts are furnished.
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

1399

Hinged Steel Poles

Applications

Lighting: General Lighting — Area — Poles and Hangers

Lighting

•	 To mount single or multiple luminaires to heights from 20 to 35
feet/6.1 to 9.1 meters. Hinged design allows easy servicing of
luminaires at shoulder height.

2"/50.8 mm Pipe Size Tenon
(2-3/8"/60.5 mm)

4.0"/
101.6
mm

Features
•	 Shafts are structural steel with a minimum yield strength of
46,000 psi.
•	 Heavy duty hinge assembly secures upper section to lower
section with high strength 3/4”/19.05 mm Dia. bolt. A flexible
protective channel is provided to protect wires when pole is
lowered.
•	 Pole counter-balance is designed to offset weight of luminaires
and is made from steel with minimum yield strength of 36,000
psi.
•	 Base plates are of structural quality hot-rolled steel with
minimum yield strength of 36,000 psi.
•	 A 3” x 5”/76.2 x 127 mm reinforced handhole with cover and
grounding lug 14”/355.6 mm above the pole base is standard.
•	 Anchor bolts are furnished complete with nuts and washers,
and are of 50,000 psi steel.

Standard Finishes
•	 Poles are finished with red-oxide prime-paint after fabrication

Options

14.0"/
355.6
mm

•	 For bronze powder coat finish (to match Appleton fixtures) add
suffix -EPX. For galvanized finish add -GAL.
•	 An optional lowering winch is available and recommended for
easy one-man operation of hinged poles. (Only one lowering
winch per installation is required because winch assembly
mounts from pole to pole and dismounts for easy storage.)
Lowering winch is furnished with mounting hardware, 25
feet/7.62 m of 3/16”/4.8 mm galvanized wire rope and safety
snap hook.

Accessory: GLW –
Lowering Device (Winch)

Dimensions may vary. Consult your local sales representative for specifications
Mounting
Height
ft/m
A

Shaft Size
(In.Sq./mm.Sq. x Ga.)

Base
Base Size
Bolt Circle Thickness Bolt Proj.
In. Sq/mm. Sq
In/mm
In/mm
In/mm
S➊
BC
T
P

F

E

20/6.1

4/2580.6 x 7

4/2580.6 x 11

10.0/6451.6

➊

.75/19.1

20/6.1

5/3225.8 x 7

5/3225.8 x 11

11.5/7419.3

➊

1.0/25.4 2.25/57.2

24/7.32

4/2580.6 x 7

4/2580.6 x 11

10.0/6451.6.

➊

.75/19.1

24/7.32

6/3871.0 x 7

6/3871.0 x 11

12.0/7741.9

➊

1.0/25.4 2.25/57.2

30/9.14

4/2580.6 x 7

4/2580.6 x 11

10.0/6541.6

➊

.75/19.1

30/9.14

6/3871.0 x 7

6/3871.0 x 11

12.0/7741.9

➊

1.0/25.4 2.25/57.2

35/10.67

6/3871.0 x 7

6/3871.0 x 11

12.0/7741.9

➊

1.0/25.4 2.25/57.2

2.0/50.8

2.0/50.8

2.0/50.8

Anchor Bolt
Max.
Dia. x Lgth.
Proj Area
In/mm
Sq.Ft./Sq.M. ➌
.75 x 28/
9.3/0.86
19.1 x 711.2
1.0 x 40/
15.2/1.4
25.4 x 1016
.75 x 28/
6.1/0.57
19.1 x 711.2
1.0 x 40/
14.3/1.33
25.4 x 1016
.75 x 28/
2.9/0.27
19.1 x 711.2
1.0 x 40/
10.8/1.00
25.4 x 1016
1.0 x 40/
3.6/0.33
25.4 x 1016

Loading
Weight
lbs/kgs

Catalog
Number ➋

230/104.3 G-PHSM-20
350/158.8 G-PHSH-20
170/77.1 G-PHSM-24
280/127.0 G-PHSH-24
150/68.0 G-PHSM-30
240/108.9 G-PHSH-30
180/81.6 G-PHSH-35

➊ Dimensions may vary—Consult your local sales representative for specifications.
➋ Anchor bolts and nuts are furnished. For accessory lowering winch, specify Cat. No. GLW.
➌ Calculated for winds of 100 MPH/160 KPH.

1400

Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

Square Tapered Steel Poles

Applications
•	 To mount single or multiple luminaires to heights from 20 to 39
feet/6.1 to 11.9 meters.
4.0"/
101.6 mm

2"/50.8 mm
Pipe Size Tenon
(2-3/8"/60.5 mm O.D)

Lighting: General Lighting — Area — Poles and Hangers

•	 2”/0.61 mm pipe size tenon accepts a single luminaire or 2, 3,
or 4 luminaires with appropriate pole-top mounting bracket.
•	 High strength shafts have a uniform taper and are made from
11 gauge commercial quality hot rolled steel.
•	 Base plates are of structural quality hot rolled steel with
minimum yield strength of 36,000 psi.
•	 A 3” x 5”/76.2 x 127 mm reinforced handhole with cover and
grounding lug 14”/355.6 mm above the pole base is standard.
•	 Anchor bolts are furnished complete with nuts and washers,
and are of 55,000 psi steel.

Lighting

Features

Standard Finishes
•	 Poles are finished with red-oxide prime-paint after fabrication

Options
•	 For bronze powder coat finish (to match Appleton fixtures) add
Suffix -EPX. For galvanized finish add suffix -GAL.

14.0"/
355.6 mm

Dimensions may vary. Consult your local sales representative for specifications
Mounting
Height
Ft/M
A

Shaft Size ➊
Sq.In./Sq.MM. x Ft/M

Base Size
In/mm
S➋

Bolt Circle
In/mm
BC

Base
Thickness
In/mm
T➋

Bolt Proj.
In/mm
P➋

Anchor Bolt
Dia. x Lgth.
In/mm

Max. Proj Area
Sq.Ft/Sq.M ➌

Catalog
Number ➍

20/6.1

5.25 x 3.25 x 20’/
3387 x 2097 x 6.1

10.5/266.7

➋

1.0/25.4

2.25/57.2

1 x 40/
25.4 x 1016.0

9.4/0.87

G-PSTH-20

24/7.3

6.25 x 3.85 x 24’/
4032 x 2484 x 12.2

13.0/330.2

➋

1.0/25.4

2.25/57.2

1 x 40/
25.4 x 1016.0

8.9/0.83

G-PSTH-24

30/9.1

6.65 x 3.25 x 30’/
4290 x 2097 x 9.1

12.0/304.8

➋

1.0/25.4

2.25/57.2

1 x 40/
25.4 x 1016.0

5.8/0.54

G-PSTH-30

35/10.7

6.25 x 3.25 x 35’/
4032 x 2097 x 10.7

13.0/330.2

➋

1.0/25.4

2.25/57.2

1 x 40/
25.4 x 1016.0

4.4/0.41

G-PSTH-35

39/11.9

7.15 x 3.25 x 39’
4613 x 2097 x 11.9

13.0/330.2

➋

1.0/25.4

2.50/63.5

1 x 40/
25.4 x 1016.0

3.8/0.35

G-PSTH-39

➊ Shaft bottom (Sq. In.) x shaft top (Sq. In.) x shaft length to tenon.
➋ Dimensions may vary—Consult your local sales representative for specifications.
➌ Calculated for winds of 100 MPH.
➍ Anchor bolts and nuts are furnished.
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

1401

Square Steel Poles

Applications

Lighting: General Lighting — Area — Poles and Hangers

Lighting

•	 To mount single or multiple luminaires to heights from 14 to 30
feet/4.3 to 9.1 meters.

Features

4.0"/
101.6
mm

•	 2”/50.8 mm pipe size tenon accepts a single luminaire, or 2, 3,
or 4 luminaires with appropriate pole-top mounting bracket.
•	 High strength shafts are made from square steel structural tube
with minimum yield strength of 46,000 psi.
•	 Base plates are of structural quality hot-rolled steel with
minimum yield strength of 36,000 psi.
•	 A 3” x 5”/76.2 x 127 mm reinforced handhole with cover and
grounding lug 14”/355.6 mm above the pole base is standard.
•	 Anchor bolts are furnished complete with nuts and washers,
and are of 55,000 psi steel.

2"/50.8 mm Pipe Size Tenon
(2-3/8"/60.5 mm)

Standard Finishes
•	 Poles are finished with red-oxide prime-paint after fabrication

Options
•	 For bronze powder coat finish (to match Appleton fixtures) add
Suffix -EPX. For galvanized finish add suffix -GAL.

14.0"/
355.6
mm

Dimensions may vary. Consult your local sales representative for specifications
Mounting
Height
Ft/M
A

Shaft Size ➊
In/mm

Base Size
In/mm
S➋

Bolt Circle
In/mm
BC

Base
Thickness
In/mm
T➋

Bolt Proj.
In/mm
P➋

Anchor Bolt
Dia. x Lgth.
In/mm

Max. Proj Area
Sq.Ft./Sq.M. ➌

Catalog
Number ➍

14/4.3

4” x 4” x 11Ga./
101.6 x 101.6 x 11Ga.

8.0/203.2

➋

.75/19.1

2.00/50.8

.75 x 20/
19.1 x 508.0

10.9/1.01

G-PSSM-14

14/4.3

4” x 4” x 7Ga./
101.6 x 101.6 x 11Ga.

8.0/203.2

➋

.75/19.1

2.00/50.8

.75 x 20/
19.1 x 508.0

14.4/1.34

G-PSSH-14

17/5.2

4” x 4” x 11Ga./
101.6 x 101.6 x 11Ga.

8.0/203.2

➋

.75/19.1

2.00/50.8

.75 x 20/
19.1 x 508.0

6.9/0.64

G-PSSM-17

17/5.2

4” x 4” x 7Ga./
101.6 x 101.6 x 7Ga.

8.0/203.2

➋

.75/19.1

2.00/50.8

.75 x 20/
19.1 x 508.0

11.9/1.11

G-PSSH-17

20/6.1

4” x 4” x 7Ga./
101.6 x 101.6 x 7Ga.

8.0/203.2

➋

.75/19.1

2.00/50.8

.75 x 20/
19.1 x 508.0

10.1/0.94

G-PSSM-20

20/6.1

5” x 5” x 7Ga./
127.0 x 127.0 x 7Ga.

11/279.4

➋

1.0/25.4

2.25/57.2

1 x 40/
25.4 x 1016

17.2/1.60

G-PSSH-20

24/7.3

5” x 5” x 7Ga./
127.0 x 127.0 x 11Ga.

11/279.4

➋

1.0/25.4

2.25/57.2

1 x 40/
25.4 x 1016

11.9/1.11

G-PSSM-24

24/7.3

6” x 6” x 7Ga./
152.4 x 152.4 x 7Ga.

12.0/304.8

➋

1.0/25.4

2.25/57.2

1 x 40/
25.4 x 1016

18.8/1.75

G-PSSH-24

30/9.1

5” x 5” x 7Ga./
127.0 x 127.0 x 7Ga.

11/279.4

➋

1.0/25.4

2.25/57.2

1 x 40/
25.4 x 1016

6.9/0.64

G-PSSM-30

30/9.1

6” x 6” x 7Ga./
152.4 x 152.4 x 7Ga.

12.0/304.8

➋

1.0/25.4

2.25/57.2

1 x 40/
25.4 x 1016

11.7/1.09

G-PSSH-30

➊ Shaft bottom (Sq. In.) x shaft top (Sq. In.) x shaft length to tenon.
➋ Dimensions may vary—Consult your local sales representative for specifications.
➌ Calculated for winds of 100 MPH.
➍ Anchor bolts and nuts are furnished.

1402

Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

Floodlight Mounting Brackets

Single or Multiple Installation on Wall, Wood or Metal Poles

Metal Pole Brackets

Lighting

Lighting: General Lighting — Area — Poles and Hangers

Wood Pole Brackets

Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

1403

Floodlight Mounting Brackets

Single or Multiple Installation on Wall, Wood or Metal Poles

Lighting

Poletop Brackets for Metal Poles — Dimensions may vary. Consult your local sales representative for specifications
Floodlight mounting brackets for installation of 2 to 4 floodlights atop metal poles are manufactured from high-strength steel tube, and
slip-fit onto 2”/50.8 mm pipe size poletop tenons. Furnished with 3 locking setscrews and red oxide prime coat finish. Bracket tenon is
2”/50.8 mm pipe size (2-3/8”/60.5 mm O.D.).
Dimensions
17.0"/
431.8 mm

Description

17.0"/
431.8 mm

10.0"/
254.0 mm

Lighting: General Lighting — Area — Poles and Hangers

Catalog Number

Poletop Bracket for Two Luminaires

G-PB-2

Poletop Bracket for Three Luminaires

G-PB-3

Poletop Bracket for Three Luminaires (120° apart)

G-PB-3-120

Poletop Bracket for Four Luminaires (in line)

G-PB-14

Poletop Bracket for Four Luminaires

G-PB-4

1.0"/25.4 mm

5.0"/
127.0 mm
(3) 3/8"/9.7 mm x 5/8"/16.0 mm
Setscrews at 120 °

Slip-Fitter for 2"/50.8 mm
Std. Pipe

17.0"/
431.8 mm

17.0"/
431.8 mm

2.0"/
50.8 mm
Std. Pipe

20.0"/
508.0 mm

10.0"/
254.0 mm
1.0"/25.4 mm
5.0"/
127.0 mm

Slip-Fitter for 2"/50.8 mm
Std. Pipe

(3) 3/8"/9.7 mm x 5/8"/16.0 mm
Setscrews at 120 °

17.0"/
431.8 mm R.

30.0"/
762.0 mm
10.0"/
254.0 mm

30.0"/
762.0 mm

1-1/8"/
28.7 mm
Dia. Hole for
wiring

30.0"/
762.0 mm
2.0"/
50.8 mm
Std. Pipe
1.0"/25.4 mm

5.0"/
127.0 mm
(3) 3/8"/9.7 mm x 5/8"/16.0 mm
Setscrews at 120 °

17.0"/
431.8 mm R

10.0"/
254.0 mm

Slip-Fitter for 2"/50.8 mm
Std. Pipe

34.0"/
863.6 mm
2.0"/
Removable
50.8 mm
Cap
Std. Pipe
5.0"/
127.0 mm

Slip-Fitter for 2"/50.8 mm
Std. Pipe

1404

0.5"/12.7 mm
(3) 3/8"/9.7mm x 5/8"/16.0 mm
Setscrews at 120 °

Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

Floodlight Mounting Brackets

Single or Multiple Installation on Wall, Wood or Metal Poles

Poletop Reducers
Made from high strength steel tubing, complete with 3 locking setscrews and with red-oxide prime finish.

Poletop Pipe Size Reduction
In/mm

Catalog Number

2-1/2 to 2/63.5 to 50.8

G-PR-2-1/2

Lighting

Dimensions — May vary. Consult your local sales
representative for specifications
2"/50.8 mm Pipe Size
(2-3/8"/60.5 mm O.D.)

G-PR-3

3 to 2/76.2 to 50.8

4.0"/
101.6 mm

G-PR-3-1/2

3-1/2 to 2/88.9 to 50.8

G-PR-4

5 to 2/127 to 50.8

G-PR-5

4.0"/
101.6 mm

8.0"/
203.2 mm

Lite Mount Bars for 4, 8, or 12 Quartzlite or Areamaster Jr. Floodlights
Bars have 11 gauge steel body and 12 gauge steel cover. Two styles: to mount on 2”/50.8 mm pipe size poletop tenon, or on wood poles
using thru-bolts. Welded construction, with 3/4”/19.1 mm N.P.S. tapped hubs. Rain-tight, with red-oxide prime finish.
Dimensions — May vary. Consult your local sales
representative for specifications

Number of
Fixtures

Length A

Dim. B

Dim C

Dim. D

4

28

–

25

1-1/2

8

60

17

24-1/2

1-1/4

12

96

17

25

1-1/2

For Metal Poles

4.0"/
101.6 mm

Dimensions For Mounting Quartzlites or Areamaster Jr.
Number of Fixtures For
Mounting

Catalog Number
Metal Pole
Wood Pole

4 Fixtures

G-PQM-4T

G-PQM-4W

8 Fixtures

G-PQM-8T

G-PQM-8W

12 Fixtures

G-PQM-12T

G-PQM-12W

Bar Assembly for 2"/50.8 mm
Pipe Size Tenon

(3) Setscrews

2"x4"/50.8 x 101.6 mm
Access Door

NPT Light Mount Type

For Wood Poles
NPT Light Mount Type

11.0"/
279.4 mm

2"x4"/
50.8 x 101.6 mm
Access Door

11/16"/17.5 mm Dia. Holes

4.0"/
101.6 mm

Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

1405

Lighting: General Lighting — Area — Poles and Hangers

4 to 2/101.6 to 50.8

Floodlight Mounting Brackets

Single or Multiple Installation on Wall, Wood or Metal Poles

Dimensions may vary. Consult your local sales representative for specifications
Description
Lighting

For Floodlights with 2”/50.8 mm Slip-Fitter, or will mount G-PB
Series brackets with floodlights.
•	 Complete with two 13”/330.2 mm-long bolts, washers, and
nuts.
•	 Red oxide prime coat finish.

Lighting: General Lighting — Area — Poles and Hangers

8-1/2"/
215.9 mm

8.0"/
203.2 mm

Catalog Number

Wood Pole or Wall Mounting Bracket

5.0"/
127.0 mm

2"/50.8 mm
Pipe
7-1/2"/
190.5 mm

G-PCB-1

G-PWB-1

Wood Pole Clamp Brackets
•	 Pole clamping floodlight mounting brackets constructed of
2”/50.8 mm steel pipe.
•	 Furnished complete with clamping bolts and nuts.
•	 Has red oxide primer coat finish.
•	 For 1 to 3 floodlights—Fits 6”/152.4 mm to 9”/228.6 mm poles.
•	 For 4 floodlights—Fits 9”/228.6 mm to 12”/304.8 mm poles.
1 Arm

G-PCB-1

2 Arm

G-PCB-2

3 Arm

G-PCB-3

4 Arm

G-PCB-4

G-PCB-2

G-PCB-3

G-PCB-4
6"/152.4 mm Channel
@ 8.2 lbs/3.7 kgs

6.0"/
152.4 mm

24.0"/
609.6 mm

9/16"/0.56 mm Dia.
holes for floodlight mounting

24.0"/
609.6 mm

1-1/2"/
38.1 mm

9.0"/228.6 mm

24.0"/
609.6 mm

6.0"/
152.4 mm

Mounting arm made of rugged angular steel stock with 	
1/4” supporting struts. Has hot-dipped galvanized finish. 	
Furnished with all nuts and bolts to assemble and install 	
bracket to wood pole.

2 holes, 7/8"/
22.4 mm Dia.
(3/4"/19.1 mm Dia.
thru-bolts furnished)

12.0"/304.8 mm

4" x 3"x 1/4"/
101.6 x 76.2 x 6.4 mm
Angle

1406

Wood Pole Crossarm Lite Mount Bracket

4-Lite

G-PCAB-4

Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

AHG and UNJ Flexible Fixture Hangers

Malleable Iron. Ball Type.:15° Swing. Cushion Type: 8° Swing
UNILETS® for Use with Threaded Rigid Metal Conduit and IMC.

Applications
•	 AHG cushion hangers are enclosed and gasketed—ideal where
dust and dampness are present.

Features

AHG5050

UNJ-50

Illustrated Features
Lighting

•	 All hangers
— All fixture hangers protect fixture against wind and vibration
damage.
— Cushion type for added protection where lighting fixtures are
subjected to vibration.
•	 AHG hangers
— Enclosed and gasketed.
— Neoprene diaphragm keeps moisture and dirt out of system.
— Cushion type permits 8° swing from vertical.
•	 UNJ hangers
— Economical general purpose hanger.
— Permits 15° swing.

Standard Materials
•	 AHG fixture hangers: malleable iron
•	 UNJ fixture hangers: malleable iron and steel

Standard Finishes

Lighting: Flexible Fixture Hangers — Ordinary Location

•	 AHG: triple-coat—(1) zinc electroplate, (2) chromate, and (3)
epoxy powder coat
•	 UNJ: malleable iron and steel parts, zinc electroplate and clear
chromate

Certifications and Compliances
•	 CSA Certified: 065180 (UNJ)
•	 UL Listed: E109438 (AWG)

Fixture Stem
Size (Inches)

Male Nipple
Size (Inches)

Length A
in/mm

Support Weight
(lbs/kg)

Catalog
Number

AHG — Fixture Hangers — Cushion Type — Enclosed and Gasketed — Cushions 40 lbs./18.0 kg.

A

1/2

1/2

3.19/81.0

1/2

3/4

3.19/81.0

3/4

3/4

3.19/81.0

AHG5050
40/18

AHG7550
AHG7575

Cushion
UNJ — Fixture Hangers — Malleable Iron and Steel — Ball Type
1/2

1/2

4.00/101.6

3/4

3/4

4.00/101.6

120/54

UNJ-50
UNJ-75

A

Ball

Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

1407

AL Ball and Cushion Flexible Fixture Hangers

UNILETS® for Use with Threaded Rigid Metal Conduit and IMC. Ball Joint Permits 20° Swing.

Applications
•	 Designed for suspension of HID, fluorescent and incandescent
lighting fixtures.
•	 Functions as combination conduit outlet box and hanger.

Lighting

Features
•	 Protects fixture against wind and vibration damage.
•	 Cushion type for added protection where lighting fixtures are
subjected to vibration.
•	 Dual function—conduit outlet box and fixture hanger.
•	 Choice of ball or cushion type.
•	 Swivel joint construction—allows 20° swing from vertical.
•	 Cushion style, with conical spring, supports up to 120 lbs/54 kg.
•	 Cushion type has setscrew for locking fixture stem.
•	 Fixture and hanger stem can be wired at work bench.
•	 Connection block available for convenient wiring of fixture leads.

ALA — Ball Hanger

ALC — Ball Hanger

ALL — Cushion Hanger

ALT — Cushion Hanger

Standard Materials
•	 Malleable iron with steel cover

Standard Finishes

Lighting: Flexible Fixture Hangers — Ordinary Location

•	 Malleable iron parts: triple-coat—(1) zinc electroplate, 	
(2) chromate, and (3) epoxy powder coat
•	 Steel parts: zinc electroplate

Certifications and Compliances
•	 UL Listed: E109438

Illustrated Features

1408

Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

AL Ball and Cushion Flexible Fixture Hangers

UNILETS® for Use with Threaded Rigid Metal Conduit and IMC. Ball Joint Permits 20° Swing.

Conduit Size
(Inches)

Fixture Stem Size
(Inches)

Support Weight
(lbs/kg)

Catalog
Number

ALA — Ball Hanger
1/2

1/2

3/4

1/2

3/4

3/4

250/112.5
250/112.5

ALA50-B
ALA7550-B
ALA75-B

ALA — Cushion Hanger — Furnished with a 3/4” to 1/2 reducer for 1/2” stems
1/2

3/4 or 1/2

3/4

3/4 or 1/2
3/4 or 1/2
3/4 or 1/2

1/2

3/4 or 1/2

3/4

3/4 or 1/2

1/2

1/2

3/4

1/2

1

1/2

3/4

3/4

1

3/4

12 to 48/5.4 to 21.6
48 to 120/21.6 to 54.0

ALA50-12
ALA7575-12
ALA50-48

Lighting

1/2
3/4

3 to 12/1.4 to 5.4

ALA7575-48
ALA50-120
ALA7575-120

Lighting: Flexible Fixture Hangers — Ordinary Location

ALC — Ball Hanger
ALC50-B
250/112.5

ALC7550-B
ALC1050-B

250/112.5

ALC75-B
ALC1075-B

ALC — Cushion Hanger — Furnished with a 3/4” to 1/2” reducer for 1/2” stems
1/2

3/4 or 1/2

3/4

3/4 or 1/2

ALC50-12
3 to 12/1.4 to 5.4

ALC7575-12

1

3/4 or 1/2

ALC1075-12

1/2

3/4 or 1/2

ALC50-48

3/4

3/4 or 1/2

1

3/4 or 1/2

1/2

3/4 or 1/2

3/4

3/4 or 1/2

1

3/4 or 1/2

Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

12 to 48/5.4 to 21.6

ALC7575-48
ALC1075-48
ALC50-120

48 to 120/21.6 to 54.0

ALC7575-120
ALC1075-120

1409

AL Ball and Cushion Flexible Fixture Hangers

UNILETS® for Use with Threaded Rigid Metal Conduit and IMC. Ball Joint Permits 20° Swing.

Conduit Size
(Inches)

Fixture Stem Size
(Inches)

1/2

1/2

Support Weight
(lbs/kg)

Catalog
Number

ALL — Ball Hanger
3/4

1/2

3/4

3/4

250/112.5
250/112.5

ALL50-B
ALL7550-B
ALL75-B

Lighting: Flexible Fixture Hangers — Ordinary Location

Lighting

ALL — Cushion Hanger — Furnished with a 3/4” to 1/2” reducer for 1/2” stems
1/2

3/4 or 1/2

3/4

3/4 or 1/2

1/2

3/4 or 1/2

3/4

3/4 or 1/2

1/2

3/4 or 1/2

3/4

3/4 or 1/2

1/2

1/2

3/4

1/2

1

1/2

3/4

3/4

3 to 12/1.4 to 5.4
12 to 48/5.4 to 21.6
48 to 120/21.6 to 54

ALL50-12
ALL7575-12
ALL50-48
ALL7575-48
ALL50-120
ALL7575-120

ALT — Ball Hanger

1

ALT50-B
250/112.5

ALT7550-B
ALT1050-B
ALT75-B

250/112.5

3/4

ALT1075-B

ALT — Cushion Hanger — Furnished with a 3/4” to 1/2” reducer for 1/2” stems

1410

1/2

3/4 or 1/2

3/4

3/4 or 1/2

1

3/4 or 1/2

1/2

3/4 or 1/2

3/4

3/4 or 1/2

ALT50-12
3 to 12/1.4 to 5.4

ALT7575-12
ALT1075-12
ALT50-48

12 to 48/5.4 to 21.6

ALT7575-48

1

3/4 or 1/2

ALT1075-48

1/2

3/4 or 1/2

ALT50-120

3/4

3/4 or 1/2

1

3/4 or 1/2

48 to 120/21.6 to 54

ALT7575-120
ALT1075-120

Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

AL Flexible Fixture Hanger Parts and Dimensions
UNILETS® for Use with Threaded Rigid Metal Conduit and IMC.

Size
(Inches)
AL — Hanger Bodies
ALA

ALC

ALL

Catalog
Number

1/2

ALA50

3/4

ALA75

1/2

ALC50

3/4

ALC75

1

ALC100

1/2

ALL50

3/4

ALL75

1/2

ALT50

3/4

ALT75

1

ALT100

Lighting

ALT

Support Weight
(lbs/kg)

Lighting: Flexible Fixture Hangers — Ordinary Location

AL — Ball Fixture Stem
BJ50

1/2
250/112.5

3/4

BJ75

AL — Cushion Fixture Stems
Fixture stem tapped for 3/4”; 3/4” to 1/2" reducer furnished for 1/2” stems. With setscrew for locking fixture stem.
3/4 or 1/2

3-12 / 1.4-5.4

CJC75-12

3/4 or 1/2

12-48 / 5.4-21.6

CJC75-48

3/4 or 1/2

48-120 / 21.6-54.0

CJC75-120

AL — Porcelain Connection Block
2 Wire, 20 Amp, 277 Volt	
Maximum Wire Size	
Two No. 10 AWG Large Terminal	
Two No. 14 AWG Small Terminal

CB202

AL Fixture Hanger Dimensions
Top View
.88"/
22.4 mm
1.81"/
46.0 mm

2.0"/
50.8 mm

Conduit Trade
Size
.25"/6.4 mm Dia.
.88"/
22.4 mm

Front View
Cushion Stem

.25"/
6.4 mm

3.00"/
76.2 mm

4.13"/
104.9 mm

Dimensions in Inches/Millimeters
A

B

1/2”

0.56/4.2

0.69/17.5

3/4”

0.69/17.5

0.69/17.5

1”

0.88/22.4

0.81/20.6

7.38"/
187.5 mm
4.00"/
101.6 mm

Side View
Ball Stem

Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

1411

JB and GS Flexible Fixture Hangers

Malleable Iron. Ball Type, 15° Swing; Cushion Type, 8° Swing
UNILETS® for Use with Threaded Rigid Metal Conduit and IMC.

Applications
•	 JB, GS and AHG cushion hangers are enclosed and gasketed—
ideal where dust and dampness are present.
•	 JB and GS hangers designed for use with JB and GS boxes.

Lighting

Features
•	 All hangers
— All fixture hangers protect fixture against wind and vibration
damage.
— Cushion type for added protection where lighting fixtures are
subjected to vibration.
•	 JB and GS hangers
— Mount directly to JB and GS cast conduit outlet boxes.
— Choice of ball or cushion type.
— Ball type permits 15° swing, cushion type 8° swing from
vertical
— Cushion type is enclosed and gasketed.

JBK-50-BS

JBK-50-CS

GSK-50-20B

GSK-50-20C

Standard Materials
•	 Malleable iron

Lighting: Flexible Fixture Hangers — Ordinary Location

Standard Finishes
•	 GS: triple-coat—(1) zinc electroplate, (2) chromate, and (3)
epoxy powder coat
•	 JB series support: zinc electroplate and clear chromate

Certifications and Compliances
•	 JB and GS cushion type hangers suitable for classified location
use in Class I, Division 2 areas, if installed in compliance with
NEC 501-9(b)
•	 CSA Certified: 065180
•	 UL Listed: E109438

Illustrated Features

Mercmaster HID Lighting Fixture

1412

Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

JB and GS Flexible Fixture Hangers

Malleable Iron. Ball Type, 15° Swing; Cushion Type, 8° Swing
UNILETS® for Use with Threaded Rigid Metal Conduit and IMC.

Fixture Stem
Size (Inches)

Male Nipple
Size (Inches)

Length A
in/mm

Support Weight
(lbs/kg)

Catalog
Number

JB—Fixture Hanger Covers — For use with JBX, JBDX and JBLX bodies — Furnished with gasket and screws
Ball Type
A

1/2

2.56/65.0

250/113

JBK-50-BS

3/4

2.56/65.0

.

JBK-75-BS

40/18

JBK-50-CS

Cushion Type
Enclosed and gasketed. Cushions 40 lbs./18.0 kg.
A

1.63/41.4

3/4

1.63/41.4

JBK-75-CS

GS—Fixture Hanger Covers (Form 20) — For use with GS and GSU bodies — Furnished with gasket and screws

Lighting

1/2

Ball Type
A

1/2

3.00/76.2

3/4

3.25/82.6

250/113

GSK-50-20B
GSK-75-20B

A

Enclosed and gasketed. Cushions 40 lbs./18.0 kg.
1/2

2.00/50.8

3/4

2.00/50.8

Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

40/18

GSK-50-20C
GSK-75-20C

1413

Lighting: Flexible Fixture Hangers — Ordinary Location

Cushion Type

SSH Flexible Fixture Hangers

Heavy Duty Outlet Box Swivel. Ball Joint Swivel Permits 20° Swing
UNILETS® for Use with Threaded Rigid Metal Conduit and IMC.

Applications
•	 Designed for suspension of HID, fluorescent and incandescent
lighting fixtures.
•	 SSH heavy duty swivel hangers for mounting to outlet and
concrete boxes.

Features
•	 Protect fixture against wind and vibration damage.
•	 Cushion type for added protection where lighting fixtures are
subjected to vibration.
•	 Heavy duty—support fixtures up to 50 lbs/22.7 kg.
•	 Steel plate serves as cover for outlet or concrete box.
•	 Ball type swivel joint permits 20°swing from vertical.

Standard Materials
Lighting

•	 Malleable iron and steel

11360

11362

Standard Finishes
•	 Malleable iron and steel parts: zinc electroplate and clear
chromate

Lighting: Flexible Fixture Hangers — Ordinary Location

Certifications and Compliances
•	 CSA Certified: 065180
•	 UL Listed: E2527
•	 UL Standard: 514A

Illustrated Features

Industrial lighting installations often employ the
use of extra heavy fixtures requiring a properly
anchored swivel attachment, assuring positive
safety to carry the necessary weight. In the Type
“SSH” Safety Swivel Hanger, the weight of the
entire suspended unit is borne by a fixture stud
instead of relying upon the screws and screw
ears of the box or ring for support. The “SSH”
hanger is furnished with a steel plate to serve
as a cover for the 4” Concrete, Octagonal, and
4-11/16” Square boxes.
Cat. No. 11360 Safety Swivel Hanger
installed in OCR3-1/2 Concrete Box
with OCP3/8 Plate

1414

Cat. No. 11362 Safety Swivel Hanger
installed in a 4-11/16” Square Box
shown with NBFS-38 (not included)

Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

SSH Flexible Fixture Hangers

Heavy Duty Outlet Box Swivel. Ball Joint Swivel Permits 20° Swing
UNILETS® for Use with Threaded Rigid Metal Conduit and IMC.

Fixture Stem Size
(Inches)

Fixture Stud Size
(Inches)

Length A
in/mm

Support Weight
(lbs/kg)

Catalog
Number

2.19/55.6

50/22.5

11360

50/22.5

11355

50/22.5

11362

Concrete Box — Safety Swivel Hanger — For Concrete Box 2-1/2” to 4” Deep

1/2

3/8

A

1/2

3/8

2.19/55.6

Lighting

Octagonal Box — Safety Swivel Hanger — For 4” Octagonal Box 1-1/2” or 2-1/8” Deep

A

1/2

3/8

2.19/55.6

A

Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

1415

Lighting: Flexible Fixture Hangers — Ordinary Location

Square Box — Safety Swivel Hanger — For 4-11/16” Square Box 1-1/2” or 2-1/8” Deep

SHC Flexible Fixture Hangers
Outlet Box Mounted Series

UNILETS® for Use with Threaded Rigid Metal Conduit and IMC.

Applications
•	 Designed for suspension of HID, fluorescent and incandescent
lighting fixtures.
•	 SHC fixture hanger covers for mounting to 3-1/4” and 4”
octagonal boxes and 4” square boxes.

Features
•	 Protect fixture against wind and vibration damage.
•	 Cushion type for added protection where lighting fixtures are
subjected to vibration.
•	 Ball type swivel joint permits 20° swing from vertical.
•	 Support fixtures with a maximum weight of 50 lbs/22.7 kg.

8438R

8458R

Standard Materials
Lighting

•	 Steel and malleable iron

Standard Finishes
•	 Malleable iron and steel parts: zinc electroplate and clear
chromate

Illustrated Features
Ball Type Swivel
Fixture Hanger
Covers shown with
octagonal and with
square stamped steel
outlet boxes.

Certifications and Compliances

Lighting: Flexible Fixture Hangers — Ordinary Location

•	 CSA Certified: 065180
•	 UL Listed: E2527
•	 UL Standard: 514A

Related Products
•	 For steel boxes, see Commercial Products section.

Fixture Stem Size
(Inches)

Length A
in/mm

Support Weight
(lbs/kg)

Catalog
Number

SHC Ball Type Swivel Hanger Covers — Permit 20° swing from vertical
For 3-1/4” and 4” Octagonal Boxes

A

1/2

1.75/44.5

50/22.5

8438R

3/4

2.00/50.8

50/22.5

8436R

1/2

1.75/44.5

50/22.5

8458R

3/4

2.00/50.8

50/22.5

8456R

For 4” Square Boxes

A

1416

Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

Flexible Fixture Hangers
Hook and Loop

UNILETS® for Use with Threaded Rigid Metal Conduit and IMC.

Applications
•	 Designed for suspension of HID, fluorescent and incandescent
lighting fixtures.

Features

EFHM

EFHF

FHS

Standard Finishes

Lighting

•	 Protect fixture against wind and vibration damage.
•	 Cushion type for added protection where lighting fixtures are
subjected to vibration.
•	 EF hook and loop hangers
— Malleable iron for strength and safety.
— Hook and loop combination permits quick disconnect and
removal of fixture for maintenance.
— Offer inexpensive means of pendant flexible suspension of
lighting fixtures.
— Permit free swing in any direction.
— EF jaw openings can be completely closed for added safety.
•	 FHS support hangers
— Provide up to 350 lbs/158.8kg support for fluorescent fixtures
on the non-electrical side of mounting.
— Straddle a maximum of 1-1/4” conduit and take 1/2” or 3/4”
fixture hook or conduit.

•	 Zinc electroplate and clear chromate

Certifications and Compliances
•	 CSA Certified: 065180

Standard Materials
•	 Malleable iron

Length A
(in/mm)

Support Weight
Lbs./Kg.

Catalog Number

1/2

2.63/66.8

200/90.0

EFHM-50

3/4

2.94/74.7

EF — Safety Support Hooks — With 3/8” jaw opening
EFHM—Male

A

EFHM

EFHM-75

EFHF—Female

A

1/2

2.00/50.8

3/4

2.05/52.1

200/90.0

EFHF-50
EFHF-75

EFHF

FHS — Support for Fixtures, Dummy Side — Straddles up to 1-1/4 trade size conduit — 11/32” diameter mounting holes, spaced
3-1/4” apart

1/2 or 3/4

A

3.31/87.1

350/157.5

FHS5075

Dimensions in Inches/Millimeters

0.38"/
9.7 mm

0.25"/
6.4 mm R

A

B

C

Catalog Number

1/2-14 NPT

2.00/50.8

2.63/66.8

EFHM-50

3/4-14 NPT

2.13/54.1

2.88/73.2

EFHM-75

1/2-14 NPT

2.00/50.8

N/A

EFHF-50

3/4-14 NPT

2.13/54.1

N/A

EFHF-75

Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

1417

Lighting: Flexible Fixture Hangers — Ordinary Location

Size
(Inches)

Flexible Fixture Hangers
Hook and Loop

UNILETS® for Use with Threaded Rigid Metal Conduit and IMC.

Applications
•	 Designed for suspension of HID, fluorescent and incandescent
lighting fixtures.

Lighting

Features
•	 Protect fixture against wind and vibration damage.
•	 Cushion type for added protection where lighting fixtures are
subjected to vibration.
•	 Malleable iron for strength and safety.
•	 Hook and loop combination permits quick disconnect and
removal of fixture for maintenance.
•	 Offer inexpensive means of pendant flexible suspension of
lighting fixtures.
•	 Permit free swing in any direction.
•	 EF and FHSN jaw openings can be completely closed for
added safety.

FHLM

FHHM

FHSN

Standard Materials
•	 Malleable iron

Standard Finishes
•	 Zinc electroplate and clear chromate

Lighting: Flexible Fixture Hangers — Ordinary Location

Certifications and Compliances
•	 CSA Certified: 065180

Illustrated Features

1418

Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

Flexible Fixture Hangers
Hook and Loop

UNILETS® for Use with Threaded Rigid Metal Conduit and IMC.

Size
(Inches)

Length A
(in/mm)

Support Weight
Lbs/Kg

Catalog Number

FH — Hanger Loops — With 5/8” diameter wireway
FHLM — Male

A

A

FHLM

1/2

3.88/98.6

3/4

4.13/104.9

350/157.5

FHLM-50
FHLM-75

FHLF — Female

FHLF

1/2

3.25/82.6

3/4

3.25/82.6

350/157.5

FHLF-50
FHLF-75

Lighting

FH — Hanger Hooks — With 5/8” diameter wireway, 3/8” jaw opening
FHHM — Male

A

A

3.88/98.6
4.13/104.9

200/90.0

FHHM-50
FHHM-75

FHHF — Female
1/2

3.25/82.6

3/4

3.25/82.6

200/90.0

FHHF-50
FHHF-75

FHHF

FHHCG—Gasketed Fixture Hanger Hook — With 5/8” wire opening, 3/8” jaw opening, safety screw — As FHHM’s above, with
internal grommet to prevent moisture and dirt entry
FHHCG — Male

A

1/2

4.25/108.0

3/4

4.25//108.0

75/34.0

FHHCG-3750-SS
FHHCG-3775-SS

FHSN — Conduit Suspension Hanger — With safety strap—clamps around rigid conduit or IMC —Has 3/8” jaw opening

A

1/2

3.13/79.5

3/4

3.25/82.6

1

3.38/85.9

Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

FHSN-50
150/67.5

FHSN-75
FHSN-100

1419

Lighting: Flexible Fixture Hangers — Ordinary Location

FHHM

1/2
3/4

Flexible Fixture Hangers

Receptacle and Hook and Loop

UNILETS® for Use with Threaded Rigid Metal Conduit and IMC.

Applications
•	 Designed for suspension of HID, fluorescent and incandescent
lighting fixtures.

Features
•	 Permit quick disconnect and removal of fixture for
maintenance.
•	 Available in pendant or feed-thru.
•	 Available with matching cord set.

Standard Materials
•	 Malleable iron with steel cover
•	 Screws: stainless steel

Lighting: Flexible Fixture Hangers — Ordinary Location

Lighting

Standard Finishes
•	 Malleable iron parts: triple-coat—(1) zinc electroplate, (2)
chromate, and (3) epoxy powder coat
•	 Steel parts: zinc electroplate
GHPHP

GHPHT

GHPHP and GHPHT — Receptacle Hangers
Conduit Hub Size
(Inches)

Catalog Number
Voltage

Hubbell Plug

Pendant

Feed-Thru

Furnished with assembled FS box, EFHM, safety lock, receptacle, and steel cover. Supports 200 lbs/ 90.7kg.

8.5”
215.9mm

GHPHP

6.06”
153.9mm

3/4

120

L5-15P

GHPHP12

GHPHT12

3/4

208, 240

L6-15P

GHPHP24

GHPHT24

3/4

277

L7-15P

GHPHP27

GHPHT27

3/4

347

L37-20P

GHPHP34 V

GHPHT34 V

3/4

480

L8-20P

GHPHP48

GHPHT48

3/4

600

L9-20P

GHPHP60 V

GHPHT60 V

GHPHT

Cord Sets — With Loop —Supplied with 600 V, 90°C 3 conductor No. 16 SOW cable, locking plug and 3/4" FHLM loop

1420

Voltage

Amperes

2'/0.6 m Cord

3'/0.9 m Cord

4'/1.21 m Cord

120

15

G-HCPL-2-12

G-HCPL-3-12

G-HCPL-4-12

208, 240

15

G-HCPL-2-24

G-HCPL-3-24

G-HCPL-4-24

277

15

G-HCPL-2-27

G-HCPL-3-27

G-HCPL-4-27

347

20

G-HCPL-2-34 V

G-HCPL-3-34 V

G-HCPL-4-34 V

480

20

G-HCPL-2-48

G-HCPL-3-48

G-HCPL-4-48

600

20

G-HCPL-2-60 V

G-HCPL-3-60 V

G-HCPL-4-60 V

Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

Power Hook for Industrial High Bay Luminaires

V

Furnished with Receptacle, Plug, 18" 16-3 SO Cord and Loop Fixture Hanger

Applications
•	 Designed for suspension of HID, ­fluorescent and incandescent
lighting fixtures.

Features

Lighting

•	 All hangers
— All fixture hangers protect fixture against wind and vibration
damage.
— Cushion type for added protection where lighting fixtures are
subjected to vibration.
•	 G-HBPH power hook for industrial luminaires
— Loop that suspends fixture cannot be removed until plug is
disconnected from power receptacle.
— 20 Amp plug, receptacle and cable are provided in all
voltages.
— Rotating plug after insertion locks plug in receptacle,
eliminating plug ­fall-out.
— Loop and hook provide flexible mounting, ideal in areas
where vibration is encountered.

Standard Materials
•	 Copperfree (4/10 of 1% max.) cast aluminum

Standard Finishes

Lighting: Flexible Fixture Hangers — Ordinary Location

•	 Powder coat epoxy

Certifications and Compliances
•	 CSA Approved

Size (Inches)

Voltage

Catalog Number

3/4

120

G-HBPH-120

3/4

208

G-HBPH-208

3/4

240

G-HBPH-240

3/4

277

G-HBPH-277

3/4

347

G-HBPH-347

3/4

480

G-HBPH-480

3/4

600

G-HBPH-600

Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

1421

BKX Rigid Fixture Hangers V

UNILETS® for Use with Threaded Rigid Metal Conduit and IMC.

Class II, Division 1 and 2, Groups E, F, G
Class III,
Enclosure 4

Applications
•	 Designed for suspension of HID, fluorescent and incandescent
lighting fixtures.

Features
•	 All fixture hangers protect fixture against wind and vibration
damage.
•	 Cushion type for added protection where lighting fixtures are
subjected to vibration.
•	 Available in three depths.
•	 Accepts JB covers for ordinary ­location and AHG hangers for
Class II hazardous locations.

BKX Shallow Box

BKX Deep Box

Standard Materials
•	 Ferrous alloy and copperfree aluminum

Certifications and Compliances

Lighting: Flexible Fixture Hangers — Explosionproof

Lighting

•	 CSA Approved

1422

Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

BKX Rigid Fixture Hangers V

UNILETS® for Use with Threaded Rigid Metal Conduit and IMC.

Class II, Division 1 and 2, Groups E, F, G
Class III,
Enclosure 4

Furnished with gasketed cover, four threaded conduit entries and 2 close-up plugs
Fixture Stem
Size (Inches)

Hub Size
(Inches)

Enclosure Only
Ferrous Alloy

Catalog Number
Enclosure Only
With Cover
Aluminum
Ferrous Alloy

With Cover
Aluminum

Shallow Box — 2-1/16
1/2

1/2

BKXS-1

BKXS-1A

BKXS-11

BKXS-11A

1/2

3/4

BKXS-2

BKXS-2A

BKXS-21

BKXS-21A

3/4

3/4

BKXS-2

BKXS-2A

BKXS-22

BKXS-22A

Medium Box — 2-11/16
1/2

1/2

BKXM-1

BKXM-1A

BKXM-11

BKXM-11A

1/2

3/4

BKXM-2

BKXM-2A

BKXM-21

BKXM-21A

1/2

1

BKXM-3

BKXM-3A

BKXM-31

BKXM-31A

3/4

3/4

BKXM-2

BKXM-2A

BKXM-22

BKXM-22A

3/4

1

BKXM-3

BKXM-3A

BKXM-32

BKXM-32A

1/2

1/2

BKXD-1

BKXD-1A

BKXD-11

BKXD-11A

1/2

3/4

BKXD-2

BKXD-2A

BKXD-21

BKXD-21A

Deep Box — 3-9/16

1

BKXD-3

BKXD-3A

BKXD-31

BKXD-31A

3/4

BKXD-2

BKXD-2A

BKXD-22

BKXD-22A

3/4

1

BKXD-3

BKXD-3A

BKXD-32

BKXD-32A

Lighting

1/2
3/4

Covers with Gasket Attached
—

—

CBK-1G

CBK-1GA

—

—

CBK-2G

CBK-2GA

Dimensions in Inches/Millimeters

Catalog Number

A

B

BKXS

1.31/33.3

1.50/38.1

BKXM

1.56/39.6

2.25/57.2

BKXD

1.56/39.6

3.00/76.2

Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

1423

Lighting: Flexible Fixture Hangers — Explosionproof

1/2
3/4

CPU and EFHU Fixture Hangers
Explosionproof, Dust-Ignitionproof
UNILETS® for use with Threaded Metal Conduit.
Class I, Division 1 and 2,Groups C, D
Class II, Division 1 and 2, Groups E, F, G
Class III

Applications
•	 Fixture hangers and accessories for suspension of industrial
type HID, incandescent, and fluorescent lighting fixtures in
Class I, Class II, and Class III classified locations.
•	 Suitable for use in areas where moisture, dust and corrosive
atmospheres are present.
•	 CPU and EFHU, EFHC, have smooth, rounded integral bushing
in each hub to protect conductor insulation.

Lighting

Features
•	 Boxes have cast mounting lugs.  Box and hub cover provide 	
a complete assembly for suspending lighting fixtures in
classified locations.
•	 CPU20 Hangers are used where fixture stem is less than 12”
long or with EXJF, ESD, or ESS where fixture stem is more than
12” long.
•	 EFHU Flexible Hangers meet NEC Sec. 501 requirement for
flexible suspension where fixture stem is more than 12” long.
•	 Cushion design protects against vibration, and swivel action
(any direction up to 15° from vertical) protects fixture if
accidentally struck.
•	 EFHU Flexible Cushion Hangers available in three spring ranges
to support fixture weights of 12 to 48 lbs / 5.4kg to 21.8kg and
48 to 120 lbs / 21.8kg to 54.4kg.
•	 CB205 Connection Block available for connecting all wires
without splices.
•	 Ground-joint mating surfaces assure flame-tight fit.
•	 Hanger has setscrew in stem hub to prevent fixture stem 	
from turning.

CPU

EFHU

Illustrated Features

Standard Materials
•	 CPU and EFHU: malleable iron or copperfree (4/10 of 1% max.
aluminum
•	 EFHU flexible hanger: brass fixture stem hub assembly

Lighting: Flexible Fixture Hangers — Explosionproof

Standard Finishes
•	 CPU20 rigid fixture hangers body: triple-coat – 1) zinc
electroplate, (2) chromate, and (3) epoxy powder coat
•	 CPU20 rigid fixture hangers cover: zinc electroplate and clear
chromate
•	 Separate CPU20 covers: zinc electroplate and clear chromate.
•	 EFHU flexible cushion fixture hangers: triple-coat – 1) zinc
electroplate, (2) chromate, and (3) epoxy powder coat

Certifications and Compliances
•	 UL Listed: E10444
•	 UL Standard: 886
•	 Suitable for Class I, Division 1 and 2, if installed in compliance
with NEC 501-9(a)(b) and for Class II, Division 1 and 2, if in
compliance with NEC 502-11(a)(b)

®

1424

Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

CPU and EFHU Fixture Hangers
Explosionproof, Dust-Ignitionproof
UNILETS® for use with Threaded Metal Conduit.
Class I, Division 1 and 2,Groups C, D
Class II, Division 1 and 2, Groups E, F, G
Class III

NEC Catalog Number
Conduit Size
(Inches)

Fixture Stem
Size (Inches)

Support Weight
(lbs/kg)

Malleable Iron

CSA Catalog Number
Malleable Iron

V

Aluminum

CPU Fixture Hangers — Non-Flexible Type — Form 20
Furnished with cast mounting lugs, four threaded universal 3/4” hubs, four 3/4”
to 1/2” reducers, and three 1/2” close-up plugs.
1/2 or 3/4

1/2

250/112.5

CPU20-50

CPU20-50CN

CPU20-50ACN

1/2 or 3/4

3/4

250/112.5

CPU20-75

CPU20-75CN

CPU20-75ACN

EFHU Fixture Hangers — Flexible Cushion Type — Form 20
Furnished with cast mounting lugs, four threaded universal 3/4” hubs, four 3/4”
to 1/2” reducers, and three 1/2” close-up plugs.
1/2 or 3/4

3/4

1/2 or 3/4

3/4

12 to 48/
EFHU75-48

EFHU75-48CN

—

21.8 to 54.0

EFHU75-120

EFHU75-120CN

—

1/2

250/112.5

CPSK20-50

CPSK20-50ACN CPSK20-50ACN

3/4

250/112.5

CPSK20-75

CPSK20-75ACN CPSK20-75ACN

5.4 to 21.6
48 to 120/

Lighting

CPU Fixture Hanger Covers — Non-Flexible Type — Form 20
Furnished with screws.

Lighting: Flexible Fixture Hangers — Explosionproof

EFHU Fixture Hanger Covers — Flexible Cushion Type — Form 20
Furnished with screws. 3/4” to 1/2” reducer supplied for 1/2” fixture stem.
3/4

12 to 48/
5.4 to 21.6

3/4

EFH75-48

EFH75-48CN

—

EFH75-120

EFH75-120CN

—

48 to 120/
21.8 to 54.0

CPU and EFHU Connection Block Accessory
Mounts directly to drilled and tapped pads in CPU and EFHU hangers. 	
Phenolic, with fastening strap and mounting screws.
5-Wire. 20-Amp, 300 V Max.

CB205

CB205CN

CB205ACN

2.88"/
73.2 mm

CB205

CB205CN V

Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

1425

CPU and EFHU Fixture Hangers Dimensions
Explosionproof, Dust-Ignitionproof
UNILETS® for use with Threaded Metal Conduit.

CPU50 and CPU75 Rigid Fixture Hanger
10-32 Thd.
.34"/
8.6 mm

5.56"/
141.2 mm

.25"/
6.4 mm

.75"/19.1 mm
2.00"/
50.8 mm

0.28"/
7.1 mm Dia.
2 Holes
.25"/6.4 mm - 14 Thd.

2.88"/
73.2 mm

3.69"/
93.7 mm

6.38"/
162.1mm

3.81"/
96.8 mm
4.63"/
117.6 mm

7.38"/187.5 mm

Lighting

EFHU Flexible Cushion Fixture Hanger

.75"/19.1 mm

.25"/6.4 mm

5.56"/
141.2 mm

0.28"/
7.1 mm Dia.
2 Holes
.25"/6.4mm-20 Thd.

2.00"/
50.8 mm

Lighting: Flexible Fixture Hangers — Explosionproof

2.19"/55.6 mm
6.38"/
162.1mm

7.75"/
196.9 mm

7.38"/187.5 mm
.88"/
22.4 mm

1426

Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

Flexible Fixture Hangers, EXJF Couplings, ESD and ESS Swivels
Explosionproof, Dust-Ignitionproof

UNILETS® for use with Threaded Metal Conduit. For Use with Rigid Fixture Hangers Where Fixture Stem is More Than 12”/304.8 mm Long.
Class I, Division 1 and 2, Groups A, B, C, D
Class II, Division 1 and 2, Groups E, F, G
Class III

Applications
•	 Fixture hangers and accessories for suspension of industrial
type HID, incandescent, and fluorescent lighting fixtures in
Class I, Class II, and Class III classified locations.
•	 Suitable for use in areas where moisture, dust and corrosive
atmospheres are present.

EXJF

Features
•	 EYJF Hanger Coupling
	 — Meets NEC Sec. 501 requirement for flexible suspension
where fixture stem is more than 12”/304.8 mm long.
	 — Watertight construction.
	 — Convenient method for attaching explosionproof lighting
fixtures to non-flexible hangers.
	 — Allows free swing of lighting fixture in any direction.  Absorbs
shock, prevents damage to conduit and connections.
	 — Assures plumb hanging of fixture.
	 — Both end fittings are female with removable male close
nipples. To make union end-coupling, remove nipple from either
end and thread in a 1/2” or 3/4” UNY Union.
	 — Female end fittings have setscrews with screwdriver slot to
allow locking of conduit. Prevents turning of fixture stem and
nipple.
•	 ESS and ESD swivels for use with rigid fixture hangers where
fixture stem is more than 12”/304.8 mm  long.

Standard Materials

ESD

ESS

Illustrated Features
Lighting

•	 EXJF flexible hanger couplings: outer bronze braid, inner brass
core with insulating liner and brass end fittings.
•	 ESD and ESS swivels: malleable iron.

Standard Finishes
•	 EXJF flexible couplings: natural finish.
•	 ESD and ESS swivels: triple-coat – 1) zinc electroplate, (2)
chromate, and (3) epoxy powder coat.

Lighting: Flexible Fixture Hangers — Explosionproof

Options
•	 EXJF available in stainless steel, add -SS to catalog number.

Certifications and Compliances
•	
•	
•	
•	

UL Listed: E10444
UL Standard: 886
CSA Certified: 065182
Suitable for Class I, Division 1 and 2, if installed in compliance
with NEC 501-9(a)(b) and for Class II, Division 1 and 2, if in
compliance with NEC 502-11(a)(b)

Related Products
•	 For unions, see Fittings Section.

 Shaded area on the following page indicates items suitable for Class I, Groups A and B in addition to Class I, Groups C and D; Class II, Groups E, F and G;
and Class III.
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

1427

Flexible Fixture Hangers, EXJF Couplings, ESD and ESS Swivels
Explosionproof, Dust-Ignitionproof

UNILETS® for use with Threaded Metal Conduit. For Use with Rigid Fixture Hangers Where Fixture Stem is More Than 12”/304.8 mm Long.
Class I, Division 1 and 2, Groups A, B, C, D
Class II, Division 1 and 2, Groups E, F, G
Class III

Size
(Inches)

Inches/Millimeters
Flexible Length

Catalog
Number

Overall Length

EXJF Flexible Fixture Hanger ➊

Lighting

Raintight construction. Supplied with two female hubs, each with a removable close nipple. Can
be used to make male to male, female to male or female to female. Setscrew with screwdriver slot
allows locking of conduit—prevents fixture stem from turning.
1/2

4.00/101.6

11.06/ 28.1

EXJF14

3/4

4.00/101.6

11.06/ 28.1

EXJF24

1/2

4.00/101.6

11.06/ 28.1

EXJF16

3/4

4.00/101.6

11.06/ 28.1

EXJF26

1/2

4.00/101.6

11.06/ 28.1

EXJF18

3/4

4.00/101.6

11.06/ 28.1

EXJF28

1/2

4.00/101.6

11.06/ 28.1

EXJF110

3/4

4.00/101.6

11.06/ 28.1

EXJF210

1/2

4.00/101.6

11.06/ 28.1

EXJF112

3/4

4.00/101.6

11.06/ 28.1

EXJF212

1/2

4.00/101.6

11.06/ 28.1

EXJF115

3/4

4.00/101.6

11.06/ 28.1

EXJF215

1/2

4.00/101.6

11.06/ 28.1

EXJF118

3/4

4.00/101.6

11.06/ 28.1

EXJF218

Swivel Hangers — Setscrew with screwdriver slot allows locking of conduit — Prevents fixture stem from turning
ESD Swivel

Lighting: Flexible Fixture Hangers — Explosionproof

15° swivel from center and full 360° free swing.
1/2

ESD50 ➋

3/4

ESD75 ➋

ESS Swivel
15° swivel from center.
1/2

ESS50 ➋

3/4

ESS75 ➋

➊ Available in stainless steel. Add suffix -SS to catalog number. Consult your local sales representative.
➋ Not CSA Certified.
 Shaded area indicates items suitable for Class I, Groups A and B in addition to Class I, Groups C and D; Class II, Groups E, F and G; and Class III.

1428

Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

Flexible Fixture Hangers, EXJF Couplings, ESD and ESS Swivel Dimensions
Explosionproof, Dust-Ignitionproof

UNILETS® for use with Threaded Metal Conduit. For Use with Rigid Fixture Hangers Where Fixture Stem is More Than 12”/304.8 mm Long.

ESS Swivel

ESD Swivel
3.00"/
76.2 mm

3.00"/
76.2 mm

3.94"/
100.1 mm
3.31"/
84.1 mm

1.88"/
47.8 mm

2.31"/
58.7 mm

3.00"/
76.2 mm

EXJF
Lighting

A

Dimensions in Inches/Millimeters
B

C

1/2

3.38/85.9

1.88/47.8

1.44/ 36.6

3/4

3.38/85.9

1.88/47.8

1.75/44.5

Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

Lighting: Flexible Fixture Hangers — Explosionproof

Size
Inches

1429

EFHC and EFHCA Fixture Hangers and Accessories
Explosionproof, Dust-Ignitionproof
UNILETS® for use with Threaded Metal Conduit.
Class I, Division 1 and 2, Groups A*, B, C, D
Class II, Division 1 and 2, Groups E, F, G
Class III

Applications
•	 Fixture hangers and accessories for suspension of industrial
type HID, incandescent, and fluorescent lighting fixtures in
Class I, Class II, and Class III classified locations.
•	 Suitable for use in areas where moisture, dust and corrosive
atmospheres are present.
•	 EFHC and EFHCA hangers have smooth, rounded integral
bushing in each hub to protect conductor insulation.

Features
•	 EFHC and EFHCA Fixture Hangers are used where fixture stem
is less than 12”/304.8 mm long or with EXJF, ESD, or ESS where
fixture stem is more than 12”/304.8 mm long.
•	 Raintight when used with O-Ring.
•	 Provided with threaded removable cover for convenience in
pulling or splicing conductors.
•	 Mounting strap available for fastening EFHC or EFHCA to a
mounting surface.
•	 CB202 connection block available for convenience in
connecting line and fixture wires without splices.
•	 Hanger has setscrew in stem hub to prevent fixture stem 	
from turning.

EFHC

EFHCA

Illustrated Features

Lighting

Standard Materials
•	 EFHC and EFHCA fixture hanger body: malleable iron
•	 EFHC and EFHCA fixture cover: copperfree (4/10 of 1% max.)
aluminum
•	 EFHC and EFHCA mounting strap and LC locking coupling:
steel

Standard Finishes

Lighting: Flexible Fixture Hangers — Explosionproof

•	 EFHC and EFHCA fixture hanger body: triple-coat – 1) zinc
electroplate, (2) chromate, and (3) epoxy powder coat
•	 EFHC and EFHCA fixture hanger cover: epoxy powder coat
•	 EFHC/EFHCA mounting strap and LC locking coupling: zinc
electroplate

Certifications and Compliances
•	
•	
•	
•	

UL Listed: E10444
UL Standard: 886
CSA Certified: 025875
Suitable for Class I, Division 1 and 2, if installed in compliance
with NEC 501-9(a)(b) and for Class II, Division 1 and 2, if in
compliance with NEC 502-11(a)(b)

 Shaded area on following page indicates items suitable for Class I, Groups B, C and D; Class II, Groups E, F and G; and Class III. Sealing fitting must be
installed adjacent to enclosure for all conduits for Group B location (EFHC Series).
* Suitable for Class I, Groups A, B, C, D.

1430

Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

EFHC and EFHCA Fixture Hangers and Accessories
Explosionproof, Dust-Ignitionproof
UNILETS® for use with Threaded Metal Conduit.
Class I, Division 1 and 2, Groups A*, B, C, D
Class II, Division 1 and 2, Groups E, F, G
Class III

Conduit Size (Inches)

Fixture Stem Size (Inches)

Catalog Number

EFHC Fixture Hanger
Class I, Groups B, C and D
Class II, Groups E, F and G
Class III
3/4

1/2

EFHC755 

3/4

3/4

EFHC7575 

1

1/2

EFHC1050 

1

3/4

EFHC1075 

EFHCA Fixture Hanger
Class I, Groups A*, B, C and D
Class II, Groups E, F and G
Class III
3/4

1/2

EFHCA7550 *

3/4

3/4

EFHCA7575 *

1

1/2

EFHCA1050 *

1

3/4

EFHCA1075 *

EFHC and EFHCA Connection Block Accessory – Porcelain

Lighting

Designed to fit in hanger without fastening.
2 Wire, 20 Amp 277 Volt
Maximum Wire Size
Two No. 10 AWG large terminal
Two No. 14 AWG small terminal

CB202

EFHC and EFHCA Steel Mounting Strap
For fastening EFHC or EFHCA to a mounting surface.

Add suffix S

Dimensions
EFHCA and EFHC Fixture Hangers

0.13"/
3.3 mm

5.69"/
144.5 mm

FHS Rigid Support

4.31"/
109.5 mm

0.94"/
23.9 mm

4.56"/
115.8 mm
3.25"/
82.6 mm

1.13"/
28.7 mm

5.31"/
134.9 mm

EFHC:
2.81"/
71.4 mm

2.25"/
57.2 mm

.34"/
8.6 mm Dia.
2 Holes

0.25"/
6.4 mm

1.75"/
44.5 mm
3.31"/
84.1 mm

EFHC:
3.13"/
79.5 mm

3.75"/
95.3 mm

0.34"/
8.6 mm Dia.

0.69"/
17.5 mm

* Suitable for Class I, Groups A, B, C and D.
 Shaded area indicates items suitable for Class I, Groups B, C and D; Class II, Groups E, F and G; and Class III.
Sealing fitting must be installed adjacent to enclosure for all conduits for Group B location (EFHC Series).
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

1431

Lighting: Flexible Fixture Hangers — Explosionproof

Add suffix S to above EFHCA or EFHC catalog numbers.

GRF Conduit Outlet Boxes and Fixture Hanger Covers and Canopies
Explosionproof, Dust-Ignitionproof
UNILETS® for use with Threaded Metal Conduit.
Class I, Division 1 and 2, Groups C, D
Class II, Division 1 and 2, Groups E, F, G
Class III

Applications
•	 Fixture hangers and accessories for suspension of industrial
type HID, incandescent, and fluorescent lighting fixtures in
Class I, Class II, and Class III classified locations.
•	 Suitable for use in areas where moisture, dust and corrosive
atmospheres are present.
•	 GRF conduit outlet boxes have smooth, rounded integral
bushing in each hub to protect conductor insulation.

Features
•	 GRF conduit outlet box with fixture hanger canopy or cover is
used where fixture stem is less than 12”/304.8 mm long or with
EXJF, ESD, or ESS where fixture stem is more than 12” long.
•	 Raintight when used with O-Ring.
•	 For use with hub cover or canopy. canopy has threaded cover
opening for convenience in splicing conductors.
•	 Cover and canopy hubs have set-screws with screwdriver slots
to allow locking of conduit. Prevents fixture stem form turning.

GRFC

GRF Canopy

Illustrated Features

Standard Materials
•	 Malleable iron or copperfree (4/10 of 1% max.) aluminum

Standard Finishes
•	 Bodies: triple-coat – 1) zinc electroplate; (2) chromate, and (3)
epoxy powder coat
•	 Covers and canopies: zinc electroplate and clear chromate

Lighting: Flexible Fixture Hangers — Explosionproof

Lighting

Certifications and Compliances
•	 UL Standard: 886
•	 Suitable for Class I, Division 1 and 2, if installed in compliance
with NEC 501-9(a)(b) and for Class II, Division 1 and 2, if in
compliance with NEC 502-11(a)(b)

Dimensions in Inches/Millimeters
GRF Conduit Outlet Box

GRF Canopy
2.31"/
58.7 mm

.38"/
9.7 mm

5.38"/
136.7 mm
3.38"/
85.9 mm

.81"/
20.6 mm

4.75"/
120.7 mm

3.81"/
96.8 mm
3.38"/
85.9 mm

3.88"/
98.6 mm
3.00"/
76.2 mm

1.50"/
38.1 mm

2.13"/
54.1 mm

3.81"/
96.8 mm

.38"/
9.7 mm

1432

.56"/
14.2 mm

1.19"/
30.2 mm

Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

GRF Conduit Outlet Boxes and Fixture Hanger Covers and Canopies
Explosionproof, Dust-Ignitionproof
UNILETS® for use with Threaded Metal Conduit.
Class I, Division 1 and 2, Groups C, D
Class II, Division 1 and 2, Groups E, F, G
Class III

NEC Catalog Number
Conduit Size
(Inches)

Fixture Stem Size
(Inches)

Malleable Iron

CSA Catalog Number
Aluminum

V

Malleable Iron

GRF Flanged Conduit Outlet Boxes — Form 1, Less Cover — For use with GRF fixture hanger canopies and covers below — Nominal
diameter of cover opening is 3-3/8” — Furnished with threaded hubs and ground screw — Flange has four 3/8” mounting slots
GRFC-50LC

—

GRFC-50LCCN

3/4

GRFC-75LC

—

GRFC-75LCCN

1

GRFC-100LC

—

GRFC-100LCCN

1/2

GRFL-50LC

—

GRFL-50LCCN

3/4

GRFL-75LC

—

GRFL-75LCCN

1

GRFL-100LC

—

GRFL-100LCCN

1/2

GRFT-50LC

—

GRFT-50LCCN

3/4

GRFT-75LC

—

GRFT-75LCCN

1

GRFT-100LC

—

GRFT-100LCCN

1/2

GRFX-50LC

—

GRFX-50LCCN

3/4

GRFX-75LC

GRFX-50ALCCN

GRFX-75LCCN

1

GRFX-100LC

GRFX-75ALCCN

GRFX-100LCN

Lighting

1/2

GRF Fixture Covers – Form 1 — Furnished with external threads for attachment to GRF mounting box above
Threaded Hub Cover
GRK-50

—

GRK-50CN

3/4

GRK-75

—

GRK-75CN

3/4

GRK-75U

—

GRK-75UCN

Union Hub Cover

GRF Fixture Canopies – Form 1 — Furnished with external threads for attachment to GRF mounting box above — Threaded cover
opening on side for convenience in splicing

Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

1/2

GRK-50C

—

GRK-50CCN

3/4

GRK-75C

—

GRK-75CCN

    1

GRK-100C

—

GRK-100CCN

1433

Lighting: Flexible Fixture Hangers — Explosionproof

1/2

Fixture Hanger Bracket and Accessories
UNILETS® for use with Threaded Metal Conduit.

NPT Size (Inches)

Support Weight (lbs/kg)

Catalog Number

Fixture Hanger Brackets
Suitable for use with fixtures with 3/4-14 NPT conduit openings or hubs. Mounts directly to ceiling or
wall separately from conduit system.  Catalog number includes two brackets and two hexhead bolts.  
Iron with gray epoxy finish.
3/4

200/90.0

Ceiling Mount
Projects light downward (90°).
Shown mounted to Appleton
AH260-118 explosionproof
fluorescent lighting fixture.

FHS1

Wall Mount
Projects light at 45° angle. Shown
mounted to Appleton AH260-118
explosionproof fluorescent lighting
fixture.

Safety Support Hooks and Rigid Support for Dummy Side of Lighting Fixtures
Complete assembly includes two hooks and one rigid support.  Each hook supplied with a screw for
closing 3/8” jaw opening.  Rigid Support straddles max. 1-1/4” conduit. (Chain shown in installation
view not furnished.)

Lighting: Flexible Fixture Hangers — Explosionproof

Lighting

3/4

200/90.0

AC-KT

LC Steel Locking Couplings
Setscrews with Allen head fasten on outside of hub and fixture stem.  Prevents fixture stem from turning
in hubs not normally supplied with setscrews.  3/4” fixture stem.
3/4

—

SLC75

1

—

SLC1075

200/90.0

EFHM-50

Safety Support Hooks for Dummy Side of Lighting Fixtures
Supplied with screw for closing 3/8” jaw opening.
Male
1/2

EFHM-75

3/4
Female
1/2

200/90.0

EFHF-50
EFHF-75

3/4
Rigid Support for Fluorescent Lighting Fixtures (Dummy Side)
Will straddle max. 1-1/4” conduit.
1/2 and 3/4

1434

350/157.5

FHS5075

Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

Fixture Hanger Bracket and Accessories
UNILETS® for use with Threaded Metal Conduit.

Dimensions of FHS1 Fixture Hanger Bracket

2.50"/
63.5 mm

3/4 - 14 Tapered
Pipe Thread
2.50"/63.5 mm

0.19"/4.8 mm R18

1.25"/
31.8 mm
1.25"/31.8 mm

1.13"/28.7 mm Dia. Hole

1.69"/42.9 mm
6.38"/162.1 mm

1.50"/
3.81 mm

.67"/
17.0 mm

1.00"/
25.4 mm

0.5"/12.7 mm R

.67"/
17.0 mm

1.25"/31.8 mm

2.50"/
63.5 mm

.31"/7.9 mm

Lighting

Lighting: Flexible Fixture Hangers — Explosionproof

Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

1435

HID Temporary Lighting

Designed and Packaged for Quick Installation

Applications
•	 More and more contractors are using temporary HID fixtures to
light their work sites. Instead of modifying Low-Bay fixtures for
this application, McGill’s HID Temporary Lighting  allows them to
buy something faster and easier.

Lighting

Lighting: McGill Temporary

Features
•	 400 W Pulse Start Metal Halide lamp provides over 6 foot/1.8
meters candles of illumination at a 20 ft./6.1 meter mounting
height.
•	 McGill offers lighting layouts to conform with OSHA
requirements for light output.
•	 Type “O” lamp and mogul socket complies with NEC 2008
Article 410.13(F)(5) and ANSI C78.387.
•	 Quick-attach durable 10”/254 mm welded wire guard mounts
directly to the body to protect lamp and lampholder from
accidental impact.
•	 Fixture is factory wired at 120 Volt, but can be rewired internally
for other voltage settings.
•	 3'/0.9 m cord with 5-15P molded plug on end.
•	 Compact size for easy handling.
•	 Low-profile fixture design keeps it up and out of the way of
activity below.
•	 High light output and long lamp life.
•	 Open-air ballast for cooler operation.
•	 Hook with locking feature.
•	 (2) 3/4”/19.1 mm knock-outs for conduit access.
•	 Single durable package design makes it easier for distributors to
stock and more organized for contractors on the job site.
•	 Quick and easy to assemble.
•	 Optional bottom trap available.

Shown with optional bottom trap

Illustrated Feature
Spring-lock hook allows
contractors to mount the
unit in seconds, without
the need for tools.

Standard Materials
• Enclosure: Heavy-duty steel with powder coated finish
• Lamp: 400 Watt Pulse Start Metal Halide: O-Type, BT37 Clear,
EX39 (Exclusionary Mogul Base)
• Multi-Tap ballast: 120, 208, 240, 277 Volt: Factory wired at 120
Volt
• Power cord: 3 FT/0.9 M, 18/3 SJTW, 120 Volt, 15 Amp cord
complete with NEMA 5-15 molded plug
• Lamp guard: 11 ga. white painted steel
• Mounting hook: 11 ga. steel

Dimensions in Inches/Millimeters
4.26"/108.2 mm
3.52"/
89.4 mm

Certifications and Compliances

0.12"/
3.0 mm

2.21"/
0.7 mm

8.0"/2.4 mm

3 ft/0.9 m

•	 UL and cUL Listed: E196293
•	 UL Standard: UL 1598
•	 Suitable for damp locations

Options
•	 Optional bottom trap available
Catalog Number
TL40PMTO

Bottom Guard Trap

TLTRAPW

Replacement Lamp Guard

TLGUARDW

Replacement Lamp:	
400 W PSMH, O-Type, BT37 Clear, EX39

GMP400BUPS

1436

11.76"/3.6 mm

400 W Fixture with Guard

9.25"/2.8 mm

Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

String-O-Lights

Low Cost Temporary Lighting

OPEN CONDUCTOR

Applications
•	 McGill offers a variety of temporary job site lighting systems,
from reusable, low cost cable versions to an assortment of open
conductor styles.

Features

Flat Wire Cable Style

Standard Materials

FLATWIRE

Illustrated Features

Easy-Open Cages

•	 Cages: yellow plastic
•	
	
	
	
	
	

MOLDED CABLE

Certification and Compliance
Molded Cable Version
— UL Listed: E88103
— UL Standard: 1088
— Meets OSHA requirements
— CSA Certified: LL89639 V
— CSA Standard: C22.2 No. 12

Lighting: McGill Temporary

•	 They are available in 50’ to 200’/15.2 to 61 meters  lengths of 2and 3-conductor and 12 and 14 gauge wire with 5 to 10 cage/
socket assemblies.
•	 Brass sockets are enclosed in weather-resistant molded PVC,
and plastic connectors provide greater reliability.
•	 Packaging provides tangle-free, on-the-job handling and
installation.
•	 Easy-open cages snap open and closed for faster installation
without tools and easy lamp replacements.
•	 Non-corrosive cages are fastened to sockets by a non-corrosive
collar and accommodate up to 200 Watt bulbs.
•	 Cable styles meet 2008 NEC requirements.
•	 Convenient, economical temporary lighting.
•	 110’/30.5 m messenger wire available to support string where
needed.
•	 Fully assembled; ready for installation.
•	 Weather-resistant sockets.
•	 All parts sold separately.

Packaging

No. of Socket
Cages/ Spacing
Sockets Ft/M

Catalog Numbers
for A-23 Bulb

for PS-30 Bulb

Molded Cable Styles — UL Listed
12/2-SJTW cable with plug/boot on one end and connector/cap on other end

100/30.5

10

10/3.0

2252-0018

—

12/2-SJTW cable

100/30.5

10

10/3.0

2252-0019

—

12/2-STW extra hard usage cable with weather protected plug/boot

100/30.5

10

10/3.0

2252-5007 V

—

12/3-SJTW cable with 5-15 plug/boot on one end and connector/cap on other end

100/30.5

10

10/3.0

2252-0026

—

12/3-SJTW cable

100/30.5

10

10/3.0

2252-0027

—

14/2-SJTW cable

100/30.5

10

10/3.0

2252-0007

2252-0009

14/2-SJTW cable with plug/protective rubber boot  on one end

100/30.5

10

10/3.0

2252-0012

2252-0013

14/2-SJTW cable   

50/15.2

5

10/3.0

2252-0031 *

14/3-SJTW cable

100/30.5

10

10/3.0

2252-0014

2252-0015

14/3-SJTW cable with 5-15 plug/boot on one end and connector/cap on other end

100/30.5

10

10/3.0

2252-0024

2252-0025

14/3-SJTW cable   

50/15.2

5

10/3.0

2252-0034 *

—

—

* Contact Technical Service for UL data
V CSA Certification only.
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

1437

Lighting

Length
Ft/M

String-O-Lights

Low Cost Temporary Lighting

Length
Ft/M

No. of
Cages/
Sockets

Socket
Spacing
Ft/M

Catalog Number
for A-23 Bulb

for PS-30 Bulb

100/30.5

10

10/3.0

2252-0035

—

Flat Wire Styles
14/2 Flat wire cable
14/2 Flat wire cable

50/15.2

5

10/3.0

2252-0038

—

14/2 Flat wire cable

200/61.0

10

20/6.1

2252-0043

—

14/2 Flat wire cable with 1-15P plug on one end

100/30.5

10

10/3.0

2252-0040

—

14/2 Flat wire cable with 1-15P plug on one end

50/15.2

5

10/3.0

2252-0041

—

14/2 Flat wire cable with 1-15P plug on one end

200/61.0

10

20/6.1

2252-0044

—

2-conductor, 14 gauge wire

100/30.5

10

10/3.0

2252-4040

2252-4060

2-conductor, 14 gauge wire, right-hand screw shells

100/30.5

10

10/3.0

2252-1010

2252-2020

2-conductor, 14 gauge wire, left-hand screw shells

100/30.5

10

10/3.0

2253-1010

2253-2020

Flat Wire Styles with Plug

Lighting: McGill Temporary

Open Conductor Styles

2-conductor, 14 gauge wire

50/15.2

5

10/3.0

2252-0006

—

2-conductor, 14 gauge wire

200/61.0

10

20/6.1

2252-0008

2252-2008

Accessories and Replacement Parts
Catalog Number
2252-1025

Hangers (for open conductor styles)
Cages

Catalog Number
for A-23 Bulb

for PS-30 Bulb

Single plastic replacement cage only

MCG2250

—

Single plastic replacement cage with screw collar

2250-S

2255

Single plastic replacement cage with right-hand socket assembly and hanger

2252

2256

Single plastic replacement cage with left-hand socket assembly and hanger

2253

—

Single plastic replacement cage with hanger (no socket)

2254

—

2259

—

Lighting

For use with McGill String-O-Lights

For use with most types of Lampholders
Single plastic cage only
Socket/Wire Sets
Catalog Number
Weather-resistant 600 Watt/250 Volt, 4-1/2”/114.3 mm leads of 14 gauge wire, vulcanized, pigtail socket;
right-hand thread

4017

Weather-resistant 600 Watt/250 Volt, 4-1/2”/114.3 mm leads of 14 gauge wire, vulcanized, pigtail socket;
left-hand thread

4018

Messenger wire: 110’/30.5 meters 3/32”/2.3 mm dia. 7 x 7 stranded galvanized aircraft cable

2251

1438

Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

7000 Series Industrial Extension Lights

Rubber Handle without Receptacle

Features
•	 7000 Series extension lights resist damage and deterioration.
•	 Open-end or NO-ROL closed-end cages of extra-heavy,
electrically welded, wire accommodate up to 200 Watt bulbs.
•	 Ideal for use where safety codes prohibit outlets in handles.
•	 Easy relamping cage.
•	 Internal strain relief withstands 30­ lb/9.1 kg. pull test.
•	 All-weather cords with molded plugs.
•	 Long-life Levolier™ switch mechanism in handle with protective
thumb guard.

Standard Materials
•	 Cage: 10 gauge steel wire
•	 Cord: thermoplastic
•	 Handle: yellow, grease-resistant, high quality rubber

7000-SG

7001-SRG ➋

7025-SRG

7000-RIG

Options
•	 15 Amp, 120 Volt CSA Certified versions available. Items
available in a CSA version will be marked with a V.  Add the
prefix C to the beginning of the catalog number.

Certifications and Compliances ➊
UL Listed (with cord): E59071
UL Listed (without cord): E59054
UL Standard: 153
Meets OSHA requirements
CSA Certified (with cord): LL89639 V
CSA Certified (without cord): LL56247 V
CSA Standard: C22.2 No. 12

Lighting: McGill Temporary

•	
•	
•	
•	
•	
•	
•	

Lighting

7999-RGH

➊ 100 Watt Maximum for UL Listing and CSA Certification.
➋ Not UL Listed or CSA Certified.
V CSA Certification only.
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

1439

7000 Series Industrial Extension Lights

Rubber Handle without Receptacle

with out Cord

Catalog Numbers
with 1'/ 0.3m
with 25’/7.6m
16/3-SJTW Cord
16/3-SJTW Cord

with 50’/15.2m
16/3-SJTW Cord

Closed-End Extension Lights
Handle and cage

7000-G

—

7025-G

7050-G

Handle and cage with reflector

7000-RG

—

7025-RG

7050-RG

Handle and cage with switch

7000-SG

—

7025-SG

7050-SG

Handle and cage with switch and reflector

7000-SRG

7025-SRG

7050-SRG

—

7012-SRG ➊

—

7025-SRG-GFCI

Insulated cage, reflector (100 Watt max.)

7000-RIG

—

7025-RIG

7050-RIG

Non-metallic cage, reflector (100 Watt max.)

7999-RGH

—

7925-RGH

7950-RGH

6229-1 ➋

6229-2 ➋

Handle and cage with switch and reflector and GFCI

—

Replacement Cord Sets

Lighting: McGill Temporary

Cord set with molded plugs

Catalog Number ➋
for 60-100 Watt
for 200 Watt
Open-End Extension Lights (without cord)
7001-G

Handle and cage

7002-G

Handle and cage with reflector

7001-RG

7002-RG

Handle and cage with switch

7001-SG

7002-SG

Handle and cage with switch and reflector

7001-SRG

7002-SRG

Accessories and Replacement Parts
Catalog Number
With Out Reflector
With Reflector

Lighting

Cages
Closed-end cage for 7000

8171

8170

Open-end cage (100 Watt lamp max.)

8133

8162

Open-end cage (200 Watt lamp max.)

8335-2

8336

Closed-end vinyl insulated cage (100 Watt A-21)

08171

08170

Open-end vinyl insulated cage (100 Watt lamp max.)

—

08162

Open-end vinyl insulated cage (200 Watt lamp max.)

—

08336

Non-metallic cage for 7999

—

8224

Catalog Number

Catalog Number
With Out Switch
With Switch

Handles and Sockets
Handle for 7000, 7001, 7002

—

6403

6404-1

Handle and socket for 7000, 7001, 7002

—

8959

8950

Socket for 7000, 7001, 7002

—

4015

4005

9232

—

Grounding clamp

—

➊ UL Listed for cord reel usage only.
➋ Not UL Listed.

1440

Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

7000 Series Industrial Extension Lights V

CSA Certification Only. Rubber Handle without Receptacle

with out Cord

Catalog Numbers
with 1'/0.3 m
with 25’/7.6 m
16/3-SJTW Cord
16/3-SJTW Cord

with 50’/15.2 m
16/3-SJTW Cord

Closed-End Extension Lights
Handle and cage

C7000-G

—

C7025-G

C7050-G

Handle and cage with reflector

C7000-RG

—

C7025-RG

C7050-RG

Handle and cage with switch

C7000-SG

—

C7025-SG

C7050-SG

Handle and cage with switch and reflector

C7000-SRG

C7012-SRG ➊

C7025-SRG

C7050-SRG

Insulated cage, reflector (100 Watt max.)

C7000-RIG

—

C7025-RIG

C7050-RIG

Non-metallic cage, reflector (100 Watt max.)

C7999-RGH

—

C7925-RGH

C7950-RGH

C6229-1 ➋

C6229-2 ➋

Replacement Cord Sets
Cord set with molded plugs

Catalog Number ➋
for 60-100 Watt
for 200 Watt
Handle and cage

C7001-G

C7002-G

Handle and cage with reflector

C7001-RG

C7002-RG

Handle and cage with switch

C7001-SG

C7002-SG

Handle and cage with switch and reflector

C7001-SRG

C7002-SRG

Accessories and Replacement Parts
Catalog Number
With Out Reflector
With Reflector

Lighting: McGill Temporary

Open-End Extension Lights (without cord)

Cages
8171

Closed-end cage for 7000

8170

8133

8162

8335-2

8336

Closed-end vinyl insulated cage (100 Watt A-21)

08171

08170

Open-end vinyl insulated cage (100 Watt lamp max.)

—

08162

Open-end vinyl insulated cage (200 Watt lamp max.)

—

08336

Non-metallic cage for 7999

—

8224

Lighting

Open-end cage (100 Watt lamp max.)
Open-end cage (200 Watt lamp max.)

Catalog Number
With Out Switch

With Switch

Handles and Sockets
Handle for 7000, 7001, 7002

—

6403

6404-1

Handle and socket for 7000, 7001, 7002

—

8959

8950

—

4015

4005

9232

—

Socket for 7000, 7001, 7002
Grounding clamp

—

➊ CSA Listed for cord reel usage only.
➋ Not CSA Listed.
V CSA Certification only.
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

1441

7000-38 Series Industrial Extension Lights

For PAR-38 Lamps

Applications
•	 These extension lights are ideal for temporary flood lighting,
railroad car inspections, spot light inspecting of the internal
conditions of large well pipes, and other applications requiring
intense lighting.

Features
•	 7000 Series extension lights resist damage and deterioration.
•	 Open-end of extra-heavy, electrically welded, wire
accommodates up to 200 Watt bulbs.
•	 Ideal for use where safety codes prohibit outlets in handles.
•	 Easy relamping cage.
•	 Internal strain relief withstands 30­ lb/9.1 kg. pull test.
•	 All-weather cords with molded plugs.
•	 Long-life Levolier™ switch mechanism in handle with protective
thumb guard.

Standard Materials

Lighting: McGill Temporary

•	 Cage: 10 gauge steel wire
•	 Cord: thermoplastic
•	 Handle: yellow, grease-resistant, high quality rubber

7000-SG-38

Certifications and Compliances
•	 CSA Certified (with cord): LL89639
•	 CSA Certified (without cord): LL56247
•	 CSA Standard: C22.2 No. 12

with out Cord
Handle and cage

7000-G-38

Catalog Number
with 25'/7.6m
16/3-SJTW Cord

with 50'/15.2m
16/3-SJTW Cord

7025-G-38

7050-G-38

Handle and cage

C7000-G-38 V

C7025-G-38 V

C7050-G-38 V

Handle and cage with switch

7000-SG-38

7025-SG-38

7050-SG-38

Handle and cage with switch

C7000-SG-38 V

C7025-SG-38 V

C7050-SG-38 V

Lighting

Accessories and Replacement Parts
With Out Reflector

Catalog Number
With Reflector

with Trap

1455-38

—

1455-38-T

Cages
Cage for 7000-38

Catalog Number
With Out Switch
With Switch
Handles and Sockets
Handle for 7000, 7001, 7002
Grounding clamp

6403
8959

6404-1
8950

25’/7.6m
16/3-SJTW

50’/15.2m
16/3-SJTW

6229-1

6229-2

Cord Sets
Cord set with molded plugs

V CSA Certification only.

1442

Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

6000 Series Commercial-Duty Extension Lights

Polypropylene Handle with Receptacle

Features
•	 Commercial-duty extension lights resist impact, abrasion and oil.
•	 Three wire grounded handles with convenience receptacle.
•	 Easy-open, NO-ROL cage with rotating hook saves time and
permits precise lamp positioning.
•	 Plated metal parts resist rust and corrosion.
•	 All-weather cords have molded plugs.
•	 10 Amp, 125 Vac receptacle rating.
•	 Cage accommodates 100 Watt max. bulbs.
•	 Push-through switch.
•	 Accommodates 16/3 cord type only.

Standard Materials
6025-SRG

•	 Cord: 16/3-SJTW yellow thermoplastic
•	 Cage: 10 gauge steel

Standard Finish
•	 Cage: zinc-plated

Certifications and Compliances ➊
UL Listed: E59071
UL Standard: 153
Meets OSHA requirements
CSA Certified: LL89639
Meets OSHA requirements

Catalog Numbers
with 1'/0.3m
16/3-SJTW Cord

with 25’/7.6 m
16/3-SJTW Cord

with 50’/15.2 m
16/3-SJTW Cord

Handle and cage with switch and reflector

6012-SRG ➋

6025-SRG

6050-SRG

Handle and cage with switch and reflector

C6012-SRG ➌ V

C6025-SRG V

C6050-SRG V

Handle and cage with switch and reflector and GFCI

—

6025-SRG-GFCI

Lighting: McGill Temporary

•	
•	
•	
•	
•	

—

Lighting

➊ 100 Watt Maximum for UL Listing and CSA Certification.
➋ UL Listed for cord reel usage only.
➌ CSA Listed for cord reel usage only.
V CSA Certification only.
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

1443

5000 Series Industrial Extension Lights

Thermoplastic Handle With or Without Receptacle

Features
•	 Industrial-duty extension lights resist impact, abrasion and oil.
•	 Yellow handles with receptacle, yellow cords, and grounded
cages enhance safety, while easy-open cages speed relamping.
•	 All-weather cords have molded plugs for durability.
•	 Cages feature rotating hooks and NO-ROL design for accurate
light positioning.
•	 Accommodates up to 200 Watt rough service bulbs.
•	 Meets NEC requirements for power tool grounding.
•	 13 Amp, 125 Vac receptacle rating.
•	 Long-life Levolier™ switch mechanism in handle with protective
thumb guard.

5000-SRG

5000-SRG, easy open cage

Standard Materials
•	 Cords: 16/3-SJTW thermoplastic
•	 Cages: 10 gauge steel

Standard Finish
•	 Cages: zinc plated, chrome finish
•	 15 Amp, 120 Volt CSA Certified versions available. Items
available in a CSA version will be marked with a V.  Add the
prefix C to the beginning of the catalog number.

5025-SRG

Certifications and Compliances ➊
•	
•	
•	
•	
•	
•	
•	

UL Listed (with cord): E59071
UL Listed (without cord): E59054
UL Standard: 153
Meets OSHA requirements
CSA Certified (with cord): LL89639 V
CSA Certified (without cord): LL56247 V
CSA Standard: C22.2 No. 12

Lighting

Lighting: McGill Temporary

Options

➊ 100 Watt Maximum for UL Listing and CSA Certification.
V CSA Certification only.

1444

Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

5000 Series Industrial Extension Lights

Thermoplastic Handle With or Without Receptacle

with out Cord
Closed-End Extension Lights
Handle and cage
Handle and cage
Handle and cage with reflector
Handle and cage with reflector
Handle and cage with switch
Handle and cage with switch

5000-G
C5000-G V
5000-RG
C5000-RG V
5000-SG

Catalog Numbers
with 1'/ 0.3m
with 25’/7.6m
16/3-SJTW Cord
16/3-SJTW Cord

—
—
—
—
—
—

Handle and cage with switch and reflector

C5000-SG V
5000-SRG

5012-SRG ➊

Handle and cage with switch and reflector

C5000-SRG V

5012-SRG ➊

Handle and cage with switch and reflector and GFCI
Handle and cage, no receptacle
Handle and cage, no receptacle
Handle and cage with reflector, no receptacle
Handle and cage with reflector, no receptacle
Handle and cage with switch, no receptacle

5000-GN
C5000-GN V
5000-RGN
C5000-RGN V
5000-SGN

Handle and cage with switch and reflector, no receptacle

C5000-SGN V
5000-SRGN

Handle and cage with switch and reflector, no receptacle

C5000-SRGN V

Handle and non-metallic cage
Handle and non-metallic cage
Handle and non-metallic cage with reflector
Handle and non-metallic cage with reflector
Handle and non-metallic cage with switch
Handle and non-metallic cage with switch
Handle and non-metallic cage with switch and reflector

5050-G

C5025-G V
5025-RG

C5050-G V
5050-RG

C5025-RG V
5025-SG

C5050-RG V
5050-SG

C5025-SG V
5025-SRG

C5050-SG V
5050-SRG

C5025-SRG V
5025-SRG-GFCI
5025-GN

C5050-SRG V

C5025-GN V
5025-RGN

C5050-GN V
5050-RGN

C5025-RGN V
5025-SGN

C5050-RGN V
5050-SGN

C5025-SGN V
5025-SRGN

C5050-SGN V
5050-SRGN

C5025-SRGN V
5999-GH

C5050-SRGN V

C5999-GH V
5999-RGH
C5999-RGH V
5999-SGH
C5999-SGH V
5999-SRGH
C5999-SRGH V
6229-1

—

5050-GN

—
—
—
—
—
—
—
—

6229-2

Catalog Number
With Out Reflector
With Reflector
Cages
Wire cage
Vinyl insulated metal cage (100 Watt A-21)
Non-metallic cage (100 Watt A-19)

8171
08171

—

8170
08170
8224

Catalog Number
With Out Switch
With Switch
Handles and Sockets
Handle and socket for 5000
Handle and socket for 5000-N
Socket for 5000 and 5000-N

0877
0877-N
00868

0865
0865-N
868

➊ 100 Watt Maximum for UL Listing and CSA Certification.
V CSA Certification only.
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

1445

Lighting

Handle and non-metallic cage with switch and reflector
Replacement Cord Sets
Cord set with molded plugs

—
—
—
—
—
—
—
—

—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—

5025-G

Lighting: McGill Temporary

Handle and cage with switch, no receptacle

—

with 50’/15.2m
16/3-SJTW Cord

Industrial Extension Lights

Features
•	 RE-HL5SRG and RE-HL7G
	 – All-weather cords with molded plugs
	 – Long-life Levolier™ switch mechanism in handle with
protective thumb guard
•	 RE-HLG-P and RE-VHL100N
	 – Easy to handle and service
	 – Capable of long, continuous operation in some of industry’s
most demanding environments

RE-HL55RG

Standard Materials
•	
	
	
•	
	

RE-HL5SRG and RE-HL7G
– Cage: 10 gauge steel wire
– Handle: yellow, grease-resistant, high quality rubber
RE-HLG-P and RE-VHL100N
– Handle and cage: nonmetallic composition
RE-HLG-P

Certifications and Compliances

Lighting: McGill Temporary

•	 UL Listed: E65418
•	 UL Standard:153

Description

Max. Lamp
Watts

Weight Ea.
Oz./Grams

Catalog
Number

100 W

15/425

RE-HL5SRG

100 W

20/567

RE-HL7G

75 W

8/227

RE-HLG-P *

100 W

19/539

RE-VHL100N *

Grounded handlamp with switch and receptacle

With yellow malamine phenolic handle and deluxe
wire metal guard. Use with maximum 16/3 SO or
SJOOW cord.

Grounded handlamp without switch or receptacle

Lighting

With yellow rubber handle and vinyl coated wire metal
guard. Meets OSHA requirements and NEC 511.4(B)
(2) for commercial garages, repair and storage

Grounded handlamp without switch or receptacle
With yellow polypropylene handle and guard.
Meets OSHA requirements and NEC 511.4(B)(2) for
commercial garages, repair and storage

Grounded NEMA 4X handlamp without switch or receptacle
Enclosed and gasketed handlamp with yellow
polyester handle and teflon globe. For indoor use
only. Meets OSHA requirements and NEC 511.4(B)(2)
for commercial garages, repair, and storage.

* NOT UL Listed.

1446

Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

13 Watt

Handy Compact Fluorescent Work Light

Applications
•	 The compact light provides cool operation, allowing for work
in small areas without excessive heat build-up or burns from
accidental contact.

Features
•	 This energy-efficient work light features an exclusive 10,000
hour, 13 Watt rough service twin tube fluorescent lamp.
•	 Optional magnetic base with removable plastic swivel hook
available.
•	 13 Watt, 120 Volt PLC, 0.59"/15 mm lamp.
•	 Double insulated, enclosed electrical components.
•	 Convenient on/off switch under domed cap.
•	 Durable construction for industrial and commercial applications.

Standard Materials

5331-0001

•	 Cord and molded plug: 18 gauge SJTOW oil-resistant
•	 Outer tube with reflector break-resistant polycarbonate

Certifications and Compliances
•	 UL Listed: E59071
•	 UL Standard: 153

Lighting: McGill Temporary

5331-0008
(Magnetic base and removable swivel hook assembly)

Catalog Number
120V, 13 Watt lamp, 2”/50.8 mm dia., 11-1/2”/292.1 mm length with 25’/7.6 m, 18/2-SJTOW yellow cord,
in-line ballast, and built-in switch

5331-0001

Replacement 13 Watt lamp for 5331-0001 (shock resistant, rough service)

5331-0002

Magnetic base and removable swivel hook assembly

5331-0008

Scratch Guard

5331-0035

Lighting

Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

1447

13 Watt

Rough Service Fluorescent Lamp

Applications
•	 The compact light provides cool operation, protecting personnel
from accidental contact burns.

Features
•	 This 13 Watt energy-efficient work lamp provides light output
equivalent to a 75-100 Watt incandescent with lamp life rated at
10,000 hours.
•	 Optional tool tap and scratch guard are available.
•	 Reflector directs light to work surface away from eyes.
•	 Scratch guard protects light.
•	 On/off switch, located under handle is water and dust resistant.
•	 Compact ballast located in handle.
•	 Rubber bumpers and handle protect light on impact.
•	 Exclusive in-line tool tap (110 Volt) with outlet cover.

5331-0034

Standard Materials
•	 Cord and molded plug: 16 or 18 gauge SJTOW oil-resistant
•	 Adjustable hooks with cushion tips: spring steel

Certifications and Compliances

Lighting: McGill Temporary

•	 UL Listed: E59071
•	 UL Standard: 153

5331-0008
(Magnetic base and removable swivel hook assembly)

Catalog Number
Fluorescent Lamp
13 Watt Handi-Light with tool tap and scratch guard, 25’/7.6 m 16/3-SJTOW

5331-0031

13 Watt Handi-Light with scratch guard and 25’/7.6 m 18/2-SJTOW

5331-0032

13 Watt Handi-Light with  Saf-T-Tie insert: cord locking mechanism, tool tap, scratch guard and
18”/457.2 mm 16/3-SJTOW

5331-0034

Lighting

Accessories and Replacement Parts
13 Watt Handi-Light head kit with switch, ballast and scratch guard

5331-0033

Scratch guard only

5331-0035

13 Watt Handi-Light head kit with switch and scratch guard; less ballast

5331-0036

13 Watt lamp only (shock resistant, rough service)

5331-0002

Magnetic base and removable swivel hook assembly

5331-0008

1448

Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

Fluorescent Work Lights

12 Volt, 13 Watt

Applications
•	 For applications requiring low-voltage, bright, energy-efficient
lighting.

Features
•	 The light is powered by a printed circuit, solid state ballast
connected to the lamp base.
•	 Hook with protective plastic tip, allowing for the light to hang on
user’s belt or shoulder strap for hands-free operation.
•	 Models available with 20’/6.1 m 18/2-SJTOW oil-resistant, low
temperature cord or 1’/0.3 m to 5’/1.5 m neoprene black coil
cord; both with male lighter plugs on the ends.
•	 Ideal for use in confined areas.
•	 Replaceable 13 Watt, 12 Volt, 12.5 Amp Vac twin tube lamp.
•	 Ballast designed to operate at -4 °F/-20 ˚C.
•	 Ballast protected against voltage surges up to 18 Volts.
•	 Convenient on/off switch.
•	 Optional battery pack with charger available.
•	 Optional magnetic base with removable plastic swivel hook
available.

5331-0003

5331-0004

Standard Materials

Lighting: McGill Temporary

•	 Single metal hook with protective plastic tip
•	 Break-resistant polycarbonate outer tube with reflector

5331-0008
(Magnetic base and removable swivel hook assembly)

Lighting

Catalog Number
Work Lights
12 Volt, 13 Watt lamp, 2”/50.8 mm dia., 11-1/2”/292.1 mm length with 20’/6.1 m 18/2-SJTOW yellow cord
and male lighter plug

5331-0003

12 Volt, 13 Watt lamp, 2”/50.8 mm dia., 11-1/2”/292.1 mm length with 1’/0.3m-5’/1.5 m coil cord and male
lighter plug

5331-0004

Accessories and Replacement Parts
13 Watt lamp only (shock resistant, rough service)

5331-0002

Magnetic base and removable swivel hook assembly

5331-0008

Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

1449

Battery Pack with Charger

Applications
•	 Ideal for use with 12 Volt, 13 Watt fluorescent work lights when
working in remote areas. Charger plugs into 120 Vac and
charges at 1.2 amps, 12 Vdc. Charger is furnished with 6’/1.8
m cord and male lighter plug to insert into the female outlet of
the battery.  Charger then plugs directly into a 120 Volt outlet.
If battery is discharged to recommended maximum depth,
the charger requires 16 hours to fully recharge. As battery is
charged, the output of the charger reduces to low level. Battery
must be removed from the charger within three days. Fully
charged battery will operate a work light for about 5 hours
continuously

Features

Lighting

Lighting: McGill Temporary

•	
•	
•	
•	

7 Amp hour capacity, sealed lead acid type battery.
Taper charger.
Safety vent opens if battery is overheated.
Battery furnished with 1’/0.3 m power cord having female 	
12 Volt outlet.
•	 Battery pack:	
	5.75 lbs/2.6 kgs	
	6”/152.4 mm height	
	2-1/2”/63.5 mm width	
	3-1/2”/88.9 mm length

5331-0005

Standard Material
•	 Battery case: rugged nylon with double zipper, closed cell foam
padding on the sides and bottom
•	 2”/50.8 mm adjustable web belt with quick release buckle
•	 Two “D” rings to connect the hooks of the shoulder strap
•	 Shoulder strap is 60”/1524.0 mm long with 1'/0.3 m long foam
pad, adjustable strap on each end.
•	 Triangular “D” ring provides a place to hang your light to give
hands-free lighting.

Catalog Number
Battery Pack
Battery pack, charger, shoulder strap, and case with belt

5331-0005

Accessories and Replacement Parts
13 Watt, 12 Volt, 1.25 Amp DC lamp (shock resistant, rough service)

5331-0006

7 Amp hour battery assembly

5331-0007

1450

Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

Fluorescent Industrial Extension Lights

Applications
•	 Compact, lightweight with hinged hooks, these fluorescent
extension lights were designed to carry and use virtually
anywhere.

Features
•	
•	
•	
•	
•	
•	
•	

Ideal for use in confined areas.
Emanates soft, glare-free light.
Safe and durable, these lamps remain cool to the touch.
Outer tube protects 15, 8, or 4 Watt lamps.
Durable, heavy-duty construction throughout.
Low energy, long-life.
No exposed metal parts.

Standard Materials
•	 Impact resistant plastic

5330-1525

5330-0818

Certifications and Compliances
UL Listed: E59071
UL Standard: 153
Meets OSHA requirements
CSA Certified: LL89639 V
CSA Standard: C22.2 No. 12 V

15 Watt Extension Lights
Catalog Number
with 25’/7.6m Cord
with 50’/15.2m Cord
15 Watt lamp 2 -1/8”/54.1 mm dia., 22-1/2”/571.5 mm length, with SJTO yellow cord — 18/3
from 3 prong plug to ballast, 18/2 to lamp. No. F15T8/CW bulb and FS-2 starter furnished

5330-1525

15 Watt lamp 2 -1/8”/54.1 mm dia., 22-1/2”/571.5 mm length, with SJTW yellow cord — 16/3
from 3 prong plug to ballast, 18/2 to lamp. No. F15T8/CW bulb and FS-2 starter furnished

5332-1525 V

—

with 15'/4.6m
18/2-SJTO Cord

with 22'/6.7m
18/2-SJTO Cord

4 Watt, F4T5/CW; 11”/279.4 mm overall length

5330-0411

5330-0418

8 Watt, F8T5/CW; 17”/431.8 mm overall length

5330-0811

5330-0818

8 Watt, F8T5/CW; 17”/431.8 mm overall length

5332-0825 V

5332-0818 V

5330-1550

Lighting: McGill Temporary

•	
•	
•	
•	
•	

4 and 8 Watt Extension Lights

Catalog Number
Plastic shield for 5330-0411 and 5330-0418

5330-0400

Hook only for 5330-0411, -0418, -0811, and -0818

5330-0401

Plastic shield for 5330-0811 and 5330-0818

5330-0800

Plastic shield for 5330-1525

5330-1500

Hooks, plastic, set of two (2) for 5330-1525

5330-1501

V CSA Certification only..
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

1451

Lighting

Accessories and Replacement Parts

High Intensity Low-Voltage Extension Lights

Features
•	 Compact, durable, and safe 30 Watt spot and 35 Watt flood
lights.
•	 Ideal for use where low-voltage and maximum illumination are
needed.
•	 Powerpak transformer converts 120 Vac to 12 Vac, also
available as separate item.
•	 Spot and flood light available with battery clips where no voltage
conversion is necessary.
•	 Available with battery clips where no voltage conversion is
necessary.
•	 Heavy-duty cords, plugs, and connectors.
•	 TWIST-LOK connector permits economical cord and lamp
replacement.

5329-4000

Standard Materials

Lighting: McGill Temporary

• 	 Bulb and powerpak transformer
•	 Secondary cord: 50’/15.2 m 16/2-SJTO
•	 Handle: impact-resistant plastic
•	 Lens: polycarbonate

Catalog Number
with Power Pack
Transformer
with Battery Clips
Complete unit with 30 W, 50,000 candle power spot bulb; 50’/15.2 m 16/2-SJTO cord and plug

5329-4000 ➊

5329-4001 ➊

Complete unit with 35 W, 325 candle power flood bulb; 50’/15.2 m 16/2-SJTO cord and plug

5329-4010 ➋

5329-4011 ➋

Lighting

Accessories and Replacement Parts
Catalog Number
Mini-Powerpak with 5’ 16/3-SOW primary cord

5329-0015

30 Watt spot light with 50’ 16/2-SJTO cord and TWIST-LOK connector

5329-4002 ➊

35 Watt flood light with 50’ 16/2-SJTO cord and TWIST-LOK connector

5329-4012 ➋

Plastic lens

5329-4003

Lens retaining ring

5329-4004

➊ Accommodates G.E. bulb #4405 and 4405-1.
➋ Accommodates G.E. bulb #4422.

1452

Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

Mini-Powerpak Low-Voltage Extension Lights

Features
•	 Lightweight, compact transformer converts 120 Vac to 12 Vac
lighting.
•	 Under 6 lbs./2.7 kgs total weight.
•	 Transformer potted and sealed to resist moisture.
•	 Fuse protected primary fuse.
•	 TWIST-LOK connector.
•	 75 W low-voltage bulb included.

Standard Material
•	 Extension light
•	 Transformer: 3” x 3-1/2” x 7”/76.2 x 88.9 x 177.8 mm
•	 Power cord: 5’/1.5 m 16/3-SOW

Certification and Compliance

5329-7010

•	 Meets OSHA requirements

7000-G extension light with 25’/7.6 m 16/3-SJTW Cord

5329-7000

7000-RG extension light with 25’/7.6 m 16/3-SJTW Cord

5329-7010

Lighting: McGill Temporary

Catalog Number
Extension Lights
Complete unit with power supply cord, Mini-Powerpak transformer

Accessories and Replacement Parts
Mini-Powerpak with 5’/1.5 m 16/3-SOW primary cord

5329-0015

25’/7.6 m 16/3-SJTW secondary cord assy., with TWIST-LOK plug

5329-0003

75 Watt low-voltage medium base A-21 bulb

6461
Lighting

Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

1453

Fluorescent Hand Lamps

Explosionproof. 13 Watt Twin Tube and 26 Watt Quad
Class I, Division 1, Groups C, D
Class II, Division 1, Groups F, G

Features
•	 This portable, fluorescent light features durable, heavy-duty
construction with non-metallic guard, swivel hook and handle
assembly.
•	 The handle holds a 125 Volt rated ballast designed to operate
on 50 or 60 Hz with recyclable thermal protection.
•	 “T” Number: T6.
•	 Easy maintenance.
•	 Completely watertight.
•	 No exposed metal parts.
•	 900 lumens for 13 Watt unit.
•	 1800 lumens for 26 Watt unit.
•	 Corrosion-resistant.
•	 4”/101.6 mm outside diameter.
•	 23-1/2”/596.9 mm length.
•	 3-1/2 lbs/1.6 kgs.

Standard Materials
•	 Globe: tempered glass

Lighting: McGill Temporary

Certifications and Compliances

5227-0006

•	 UL Listed: E43473
•	 UL Standard: 844

Catalog Number
13 Watt Twin Tube Selection Chart
Hand lamp with 50’/15.2 m 16/3-SO cord (male plug not included)

5227-0003

Twin tube hand lamp with out cord

5227-0006

26 Watt Quad Tube Selection Chart
5227-0007

Quad tube hand lamp with out cord

5227-0008

Lighting

Hand lamp with 50’/15.2m 16/3-SO cord (male plug not included)

1454

Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

Tubular Fluorescent Inspection Light

Explosionproof. 8 Watt
Class I, Division 1, Group D
Class II, Group G

Applications
•	 This inspection light is ideal for inspection of aircraft fuel
systems because of its narrow diameter, light weight and cool
operating temperature.

Features
•	 Furnished with high impact aluminum alloy guard and nonsparking swivel hook.
•	 “T” Number: T5.
•	 Easy maintenance — only glass globe requires factory
replacement.
•	 450 lumens.
•	 2.5”/63.5 mm outside diameter.
•	 27”/685.8 mm length.
•	 3 lbs., 3 oz./1.5 kgs.

Certifications and Compliances

5227-0004

•	 UL Listed: E43473
•	 UL Standard: 844

5227-0004

Lighting: McGill Temporary

Catalog Number
Hand lamp with 50’/15.2 m 16/3-SO cord (male plug not included)

Lighting

Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

1455

Industrial Extension Lights

Explosionproof

Class I, Division 1, Groups C, D

Features
•	 This watertight portable extension light features a lightweight
aluminum alloy guard with a non-sparking swivel hook, as well
as a chemical-resistant handle and globe holder.
•	 High impact glass globe accepts an A-21.
•	 The one-piece construction of the 15 Amp, 240 Vac socket
withstands temperatures up to 360 ˚F/182 °C in service.
•	 “T” Number: T3A.
•	 Completely watertight.
•	 Accommodates 16/3-SO or 14/3-SO cord.
•	 5”/127 mm outside diameter.
•	 18-1/2”/469.9 mm length.
•	 4 lbs/1.8 kgs.

Standard Materials
•	 100 Watt rough service bulb

5227-0005

Certifications and Compliances

Catalog Number
Extension Lights
Hand lamp with 50’/15.2 m 16/3-SO cord (male plug not included)

5227-0001

Hand lamp with out cord

5227-0005

Accessories and Replacement Parts
Handle assembly and lamp holder

5227-9915

Guard and globe assembly

5227-9916

Lighting

Lighting: McGill Temporary

•	 UL Listed: E43473
•	 UL Standard: 844

1456

Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

Low-Voltage, High Intensity Hand Lamp

Explosionproof

Class I, Division 1, Groups C, D

Applications
•	 Ideal for inspecting refinery towers, manholes, or railroad tank
cars.

Features
•	 This low-voltage spotlight uses a 12 Volt, PAR-36, 30 Watt,
automotive type, sealed beam high intensity lamp.
•	 The aluminum light guard is high impact alloy and swivel hook is
non-sparking.
•	 “T” Number: T3C.
•	 30,000 beam candlepower.
•	 1/4”/6.4 mm thick glass lens.
•	 Can be powered by low-voltage transformer or alternate 12 Volt
source.
•	 5-1/2”/139.7 mm outside diameter.
•	 16”/406.4 mm length including hook.
•	 3 lbs/1.4 kgs.

5227-0002

Standard Materials
•	 Light guard: aluminum

Certifications and Compliances

Catalog Number
Hand lamp with 50’/15.2 m 16/3-SO cord (male plug not included)

5227-0002

Lighting: McGill Temporary

•	 UL Listed: E43473
•	 UL Standard: 844

Lighting

Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

1457

Incandescent Utility Lights

Applications
•	 Ideal for food processing plants, barns, garages, warehouses,
and workshops.
•	 Low cost, corrosion-resistant, enclosed utility lights, complete
with base, wiring box, and globe, are convenient to use.  

Features
•	 Fasten directly to walls, ceilings, or structural members — no
separate outlet box required.
•	 Glass or plastic globes screw out for easy replacement of A-21
bulbs (not included) up to 150 Watts.
•	 High quality materials and sockets assure long, trouble-free
service life.
•	 3-1/2”/88.9 mm diameter; 9-1/2”/241.3 mm height
•	 Two 5/16”/7.9 mm diameter mounting holes on 4-3/8”/111.3
mm centers.
•	 Moisture-resistant construction with no exposed metal parts.
•	 Large compartment for easy wiring.
•	 Super strong, impact-resistant, thermoplastic mounting unit.
•	 For use up to 100 ˚F/38 °C ambient temperature.
•	 Accommodates up to 150 Watts max. domestic A-21 bulbs.
•	 For use with either 1/2”/12.7 mm or 3/4”/19.1 mm rigid  	
non-metallic conduit.

606 with 1435-6

653

Certifications and Compliances
UL Listed: E8646
UL Standard: 1598
CSA Certified: LL56247 V
CSA Listed: C22.2 No. 250.0 V

Lighting

Lighting: McGill General

•	
•	
•	
•	

V CSA Certification only.

1458

Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

Incandescent Utility Lights

Catalog Numbers

Wiring Compartment
Cubic Inch/Cubic
Decimeter

Supply Wire
Rating
°F/°C

For damp locations

15/0.25

257/125

600

601

For damp locations

15/0.25

221/105

C600 V

C601 V

For damp locations

12/0.20

140/60

603

604

For damp locations

12/0.20

140/60

C603 V

C604 V

Sealed unit for wet locations

12/0.20

140/60

605

606

Sealed unit for wet locations

12/0.20

140/60

C605 V

C606 V

For damp locations

15/0.25

257/125

640

641

For damp locations

15/0.25

221/105

C640 V

C641 V

For damp locations

12/0.20

140/60

643

644

For damp locations

12/0.20

140/60

C643 V

C644 V

For damp locations

15/0.25

257/125

650

651

For damp locations

15/0.25

221/105

C650 V

C651 V

For damp locations

12/0.20

140/60

653

654

For damp locations

12/0.20

140/60

C653 V

C654 V

1/2"/12.7 mm
Threaded Conduit Opening

3/4"/19.1 mm
Threaded Conduit Opening

Utility light with glass globe

Utility light with clear plastic globe ➊

Utility light with red plastic globe ➊

Accessories and Replacement Parts — Additional plastic globes see Protect-O-Globes

Lighting: McGill General

Catalog Number
1435-6

Base and socket only for 600, 640, and 650

610

Base and socket only for 601, 641, and 651

611

Base and socket only for 603, 643 and 653

5213-0623

Base and socket only for 604, 644 and 654

5213-0672

Base, socket, and seal assembly only for 605

5213-0637

Base, socket, and seal assembly only for 606

5213-0638

Socket only for 15 cubic inch/ 0.25 cubic decimeter wiring compartment

600-3

Socket only for 12 cubic inch/0.20 cubic decimeter wiring compartment

606-3

Glass globe only for 600, 601, 603, and 604 - 6-11/16"/296.9 mm long

0753

Glass globe only for 605 and 606 - 6-11/16"/296.9 mm long

0753-HR ➋

Clear plastic globe only for 640, 641, 643 and 644 - 6-1/8"/6.1 mm long

649

Red plastic globe only for 650, 651, 653 and 654 - 6-1/8"/6.1 mm long

659

Green plastic globe only - 6-1/8"/6.1 mm long

669

Lighting

Protective metal cage for glass globes only

➊ Plastic globes max. 75 Watt base-up mounting.
➋ Heat resistant globes required for wet locations.
V CSA Certification only.
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

1459

Fluorescent Utility Lights

Applications
•	 Whether the application calls for securely lighting a livestock
operation, damp barn, or even a harsh, outdoor environment, 	
the 22 Watt fluorescent utility light delivers energy-efficient, 	
trouble-free service for a variety of demanding lighting needs. 	
The single unit incorporates non-corrosive construction, its 	
own wiring compartment, and an impact-resistant thermoplastic
mounting base.

Features

Lighting

Lighting: McGill General

•	 Removable globe for effortless “push-pull” relamping and
cleaning.
•	 Standard 0.59"/15 mm, 22 Watt quad-tube lamp provides 75%
greater energy efficiency.
•	 Average service life of 10,000 hours.
•	 Fastens directly to walls, ceilings, or structural members.
•	 3-1/2”/88.9 mm diameter, 9-1/2”/241.3 mm height.
•	 Two 5/16”/7.9 mm diameter mounting holes on 4-3/8”/111.3
mm centers.
•	 22 Watt, 120 Volt PLC, 0.59"/15 mm lamp equivalent to 75 Watt
incandescent.
•	 Delivered complete with globe, ballast, lamp, socket and wiring
box.
•	 For use up to 100 ˚F/38 °C ambient temperature.
•	 Use with either 1/2”/12.7 mm or 3/4”/19.1 mm rigid non-metallic
conduit.

600-FL22

Options
•	 CSA Certified versions available. Items available in a CSA
version will be marked with a V.  Add the prefix C to the
beginning of the catalog number.

Certifications and Compliances
•	
•	
•	
•	

UL Listed: E13761
UL Standard: 1598
CSA Certified: LL56247
CSA Listed: C22.2 No. 250.0

Wiring Compartment
Cubic Inch/Cubic
Decimeter

Supply Wire
Rating
°F/°C

Utility light with glass globe
For damp locations
For damp locations
Sealed unit for wet locations
Sealed unit for wet locations
Utility light with clear plastic prismatic globe
For damp locations
For damp locations

12/0.20
12/0.20
12/0.20
12/0.20

194/90
221/105
194/90
221/105

12/0.20
12/0.20

194/90
221/105

Sealed unit for wet locations ➊

12/0.20

Sealed unit for wet locations ➊
Utility light with red plastic prismatic globe
For damp locations
For damp locations
Sealed unit for wet locations ➊

Catalog Numbers
1/2"/12.7 mm
3/4"/19.1 mm
Threaded Conduit Opening Threaded Conduit Opening
600-FL22

601-FL22

C600-FL22 V
605-FL22

C601-FL22 V
606-FL22

C605-FL22 V

C606-FL22 V

640-FL22

641-FL22

194/90

C640-FL22 V
645-FL22

C641-FL22 V
646-FL22

12/0.20

221/105

C645-FL22 V

C646-FL22 V

12/0.20
12/0.20

194/90
221/105

12/0.20

194/90

650-FL22

651-FL22

C650-FL22 V
655-FL22

C651-FL22 V
656-FL22

12/0.20
221/105
Sealed unit for wet locations ➊
C655-FL22 V
Accessories and Replacement Parts — Additional plastic globes see Protect-O-Globes

C656-FL22 V

Glass globe only - 6-11/16”/220.7 mm long
Clear plastic prismatic globe only - 8-1/4”/209.6 mm long
Red plastic prismatic globe only - 8-1/4”/209.6 mm long
Protective metal cage for glass globes only
22 Watt, 120 Volt PLC,0.59" /15 mm lamp
Base, socket, and ballast assembly only for 600-FL22
Base, socket, ballast, and seal assembly only for 605-FL22

Catalog Number
0753
5213-6649
5213-6659
1435-6
5213-6660
5213-6623
5213-6625

➊ For base-up operation only.
V CSA Certification only..

1460

Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

Protect-O-Sleeves

For Fluorescent Tubes

Applications
•	 Reusable Protect-O-Sleeves encase existing fluorescent tubes
to insulate and improve lighting efficiency at low temperatures.
•	 High tensile, polycarbonate strength protects people,
equipment, and products.
•	 Available for applications requiring ultra-violet light filtering
such as museums, department stores, and art galleries, where
fluorescent lighting can deteriorate materials.

2260 (T-12)

Features
•	 Furnished with end caps that fit snugly between lamp and
sleeve.
•	 Filter Ray sleeves are designed to filter out UV rays in the range
of 0-385 nanometers when used with 400 M.A. lamps.
•	 Insulates lamps up to 2.5 times at 20 ˚F/-6 °C.
•	 Accommodates lamps up to 800 milliamps ➊.
•	 For use up to 100 ˚F/38 °C ambient temperature.
•	 Most T-8 and T-12 versions available in colors.

Certifications and Compliances

2270 (T-8)

2546 (T-5)

•	 Meets OSHA safety requirements

T-5 Clear Protect-O-Sleeves ➋
Lamp Type

Nominal Lamp Length
Inches/Millimeters

Catalog Number for Sleeve with 2 Caps
for T-5 Diameter Lamps

Box
Quantity

F-14

22/558.8

2522

48

F-21

34/863.6

2534

24

F-28

46/1168.4

2546

24

T-8 and T-12 Clear Protect-O-Sleeves ➊
Nominal Lamp Length
Inches/Millimeters

Catalog Number for Sleeve with 2 Caps
for T-12 Diameter Lamps

Catalog Number for Sleeve with 2 Caps
for T-8 Diameter Lamps

Box
Quantity

F-15

18/457.2

—

2270

24

F-20

24/609.6

2268

2278

24

F-30

36/914.4

—

2271

24

F-32

48/1219.2

—

2295

24

F-36

36/914.4

2269

—

24

F-40

48/1219.2

2260

—

24

F-40

60/1524.0

—

2286

24

F-48

46/1168.4

2261

—

24

F-60

60/1524.0

2276

—

24

F-72

72/1828.8

2262

2272

24

F-96

96/2438.4

2263

2273

24

Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

1461

Lighting

➊ No. 2285 heat sink screens must be used with T-8 and T-12 800-milliamp maximum HO lamp bases. Two heat sink screens required per sleeve (one at each
end between lamp and sleeve). HO lamps create excessive heat at the ends. The open metal mesh of the heat sink screens spreads the excess heat over a
larger area to help eliminate deterioration of the sleeve. NOT for use with VHO lamps.
➋ NOT for use with HO or VHO lamps.

Lighting: McGill Lamp Protection

Lamp Type

Protect-O-Sleeves

For Fluorescent Tubes

Clear UV Filtering Protect-O-Sleeves ➌

Lamp Type

Nominal
Lamp Length
Inches/Millimeters

Catalog Number for Sleeve with 2 Caps
for T-12 Diameter Lamps

for T-8 Diameter Lamps

Box
Quantity

F-32

48/1219.2

—

2295-FR

24

F-40

48/1219.2

2260-FR

—

24

F-96

96/2438.4

2263-FR

2273-FR

24

Colored Protect-O-Sleeves ➊
Catalog Numbers for Sleeve with 2 Caps
Lamp Type

Blue

Green

Pink

Red

Yellow

Box
Quantity

F-32, T-8

2295-B

2295-G

2295-P

2295-R

2295-Y

12

F-40, T-12

2260-B

2260-G

2260-P

2260-R

2260-Y

12

F-48, T-12

2261-B

2261-G

2261-P

2261-R

2261-Y

12

F-72, T-12

2262-B

2262-G

2262-P

2262-R

2262-Y

12

F-96, T-8

2273-B

2273-G

2273-P

2273-R

2273-Y

12

F-96, T-12

2263-B

2263-G

2263-P

2263-R

2263-Y

12

Accessories and Replacement Parts

Lighting

Lighting: McGill Lamp Protection

Catalog Number
Universal end cap for T-5, 2500 series

2508

Universal end cap for T-12, 2260 series

2265

Heat sink screen for HO lamp bases

2285 ➊

Universal end cap for T-8, 2270 and 2295 series sleeves produced prior to 8-1-97

2274

Universal end cap for T-8, 2270 and 2295 series sleeves produced after 8-1-97

2279

Universal T-8 filter ray end cap for 2273-FR and 2295-FR

6840

Universal T-12 filter ray end cap for 2260-FR and 2263-FR

6846

➊ No. 2285 heat sink screens must be used with T-8 and T-12 800-milliamp maximum HO lamp bases. Two heat sink screens required per sleeve (one at each
end between lamp and sleeve). HO lamps create excessive heat at the ends. The open metal mesh of the heat sink screens spreads the excess heat over a
larger area to help eliminate deterioration of the sleeve. NOT for use with VHO lamps.
➌ Sleeves filter out ultraviolet light in the range of 0 to 385 nanometers when used with 400 M.A. lamps. NOT for use with HO or VHO Lamps.

1462

Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

Protect-O-Tubes

For Fluorescent Tubes

Applications
•	 Protect-O-Tubes offer convenient and environmentally safe
lighting for food, drug, and related industries.

Features
•	 Complete fluorescent lighting unit
•	 Adhesively attached end caps provide added safety for glass
containment.
•	 Air space between the lamp and sleeve acts as a cushion and
helps to protect the tube from breakage and diffuses heat.
•	 Improves light transmission and provides longer lamp life.
•	 For use up to 100 ˚F/38 °C ambient temperature.
•	 Available in T-8 or T-12 versions.

Standard Finish
•	 Lighting unit: polycarbonate sleeve, lamp, and end caps
•	 End caps: polypropylene

Certifications and Compliances
•	 Approved for use by the USDA and satisfying the requirements
of OSHA and FDA
•	 Meets safety requirements

Lamp Base
Med. Bi-pin

Nominal Lamp Length
Inches/Millimeters
18/457.2

Catalog Number
of Sleeve, Lamp, and End Caps
4230

Box
Quantity
24

F-32/T-8/SP35

Med. Bi-pin

48/1219.2

4231

24

F-32/T-8/SPX35

Med. Bi-pin

48/1219.2

4232

24

F-32/T-8/SP41

Med. Bi-pin

48/ 1219.2

4233

24

F-32/T-8/SPX41

Med. Bi-pin

48/ 1219.2

4234

24

F-40/T-12/CW/RS/WM

Med. Bi-pin

48/ 1219.2

4261

24

F-40/T-12/LW/RS/WM

Med. Bi-pin

48/ 1219.2

4262

24

F-40/T-12/SPX35

Med. Bi-pin

48/ 1219.2

4265

24

F-40/T-12/D

Med. Bi-pin

48/ 1219.2

4266

24

F-40/T-12/WW

Med. Bi-pin

48/ 1219.2

4269

24

F-48/T-12/LW/WM

Single-pin

48/ 1219.2

4263

24

F-48/T-12/CW/HO

Recessed Double Contact

48/ 1219.2

4264 ➊

24

F-72/T-12/SPX35

Single-pin

72/1828.8

MCG4250

12

Single-pin

96/2438.4

4281

12

Recessed Double Contact

96/ 2438.4

4283 ➊

12

F-96/T-12/CW/WM

Single-pin

96/ 2438.4

4284

12

F-96/T-12/D/WM

Single-pin

96/ 2438.4

4285

12

F-96/T-12/WW

Single-pin

96/ 2438.4

4286

12

Recessed Double Contact

96/ 2438.4

4287 ➊

12

F-96/T-12/D
F-96/T-12/CW/HO/WM

F-96/T-12/LW/HO/WM

Single-pin

96/ 2438.4

4288

12

F-96/T-12/SP65/HO

Recessed Double Contact

96/ 2438.4

4289 ➊

12

F-96/T-12/SP41/HO

Recessed Double Contact

96/ 2438.4

4290 ➊

12

F-96/T-12/LW/WM

Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

Lighting

Note: Availability of lamp types shown above may be affected by the implementation of the Energy Policy Act of 1992.
➊ Two heat sink screens are furnished with all HO lamp styles to help eliminate excessive heat at the ends of the lamps.

Lighting: McGill Lamp Protection

Lamp Type
F-15/T-8/SPX35

1463

Tubeloc Holders

Applications
•	 Securely position and hold tubes in fluorescent fixtures

Features
•	 Shock resistant
•	 Styles to fit most fluorescent lamps in use today

Standard Finish
•	 Holders: shock resistant nylon

Certifications and Compliances
•	
•	
•	
•	

UL Listed: E59240
UL Standard: 1598
CSA Certified: LL36636
CSA Standard: C22.2

M180

Description

Catalog Number

M175

T-12 Recessed double contact; Slimline single-pin; medium bi-pin; T-17 power
groove with recessed double contact base (3/4”/19.1 mm dia. plunger)

M176

T-17 Bi-pin mogul base

M180

Lighting

Lighting: McGill Lamp Protection

T-8 and T-12 Bi-pin, 14-40 Watts

1464

Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

Protect-O-Globes

For Incandescent Bulbs

Applications
•	 Protect lamps and the working environment with economical
polycarbonate globes that are virtually unbreakable.
•	 Ideal for the replacement of glass and wire guard combinations
where incandescent or HID lamps are used in vandal-proof
applications.

Features
•	 Various styles, sizes, and colors available.
•	 Prismatic globes provide lateral light diffusion.
•	 Smooth globes reduce operating temperatures, amplify light
source.
•	 Accommodates up to 150 Watts maximum, base-up operation.

1500-C

0604AP

3316

Certifications and Compliances
•	 Meets OSHA requirements

Description

Color

Thread Diameter
In/mm

Globe Dimensions
Inches/Millimeters — W x L

Maximum
Wattage

Catalog
Number

3—1/4/82.6
3—1/4/82.6
4—1/4/108.0
3—1/4/82.6
3—1/4/82.6
3—1/4/82.6
3—1/4/82.6
3—1/4/82.6
3—3/16/81.0
3—1/4/82.6
3—1/4/82.6
3—1/4/82.6
3—1/4/82.6
3—3/16/81.0
3—1/4/82.6
3—1/4/82.6
3—1/4/82.6

3—1/2 x 8—1/4/88.9 x 209.6
3—1/2 x 8—1/4/88.9 x 209.6
4—3/4 x 8—5/16/120.7 x 211.1
3—3/4 x 6—1/4/95.3 x 158.8
3—3/4 x 6—1/4/95.3 x 158.8
3—3/4 x 6—1/4/95.3 x 158.8
3—3/4 x 6—1/4/95.3 x 158.8
3—1/2 x 6—1/4/95.3 x 158.8
3—23/32 x 6/94.5 x 152.4
3—1/2 x 6—1/4/88.9 x 158.8
3—1/2 x 6—1/4/88.9 x 158.8
3—1/2 x 6—1/4/88.9 x 158.8
3—1/2 x 6—1/4/88.9 x 158.8
3—23/32 x 6/94.5 x 152.4
3—1/2 x 6—1/4/88.9 x 158.8
3—1/2 x 6—1/4/88.9 x 158.8
3—1/2 x 6—1/4/88.9 x158.8

60
60
150
60
60
60
60
60
75
60
60
60
60
75
60
60
60

0134CP ➊
0134CS ➊
1500-C

0604GP ➊
0604RP ➊
0604AP ➊

3—3/16/81.0
4—1/4”/108.0

3—7/16 x 1—5/8/87.4 x 41.4
3—7/16 x 1—5/8/87.4 x 41.4

75
150

3316
4014

Finish

0603CS ➊
0603GS ➊
0603RS ➊
0603AS ➊
0604CS ➊
0752-C
0604GS ➊
0604RS ➊
0604AS ➊
0604CP ➊
0752-P

Dimensions
A - 3-1/2”/88.9 mm
B - 7-1/2”/190.5 mm
C - 3.0”/76.2 mm
D - 3-1/4”/82.6 mm
E - 3-3/4”/95.3 mm
F - 1/2”/12.7 mm
Cylinder Prismatic

A - 3-1/2”/88.9 mm
B - 5-1/2”/139.7 mm
C - 3.0”/76.2 mm
D - 3-1/4”/82.6 mm
E - 3-3/4”/95.3 mm
F - 1/2”/12.7 mm
Cylinder Smooth

A - 3-3/4”/95.3 mm
B - 5-1/2”/139.7 mm
C - 3.0”/76.2 mm
D - 3-1/4”/82.6 mm
E - 1/2”/12.7 mm

Bullet Smooth
Lighting

➊ Can be used with McGill Incandescent and Fluorescent Utility Lights.
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

Lighting: McGill Lamp Protection

Globes
8—1/4”/209.6 mm cylinder
Clear
Prismatic
8—1/4”/209.6 mm cylinder
Clear
Smooth
8—5/16”/211.1 mm cylinder
Clear
Smooth
6—1/4”/158.8 mm bullet
Clear
Smooth
6—1/4”/158.8 mm bullet
Green
Smooth
6—1/4”/158.8 mm bullet
Red
Smooth
6—1/4”/158.8 mm bullet
Amber
Smooth
6—1/4”/158.8 mm cylinder
Clear
Smooth
6—1/4”/158.8 mm cylinder
Clear
Smooth
6—1/4”/158.8 mm cylinder
Green
Smooth
6—1/4”/158.8 mm cylinder
Red
Smooth
6—1/4”/158.8 mm cylinder
Amber
Smooth
6—1/4”/158.8 mm cylinder
Clear
Prismatic
6—1/4”/158.8 mm cylinder
Clear
Prismatic
6—1/4”/158.8 mm cylinder
Green
Prismatic
6—1/4”/158.8 mm cylinder
Red
Prismatic
6—1/4”/158.8 mm cylinder
Amber
Prismatic
Bases
Yellow plastic base for use with 0752-C/P globes
Yellow plastic base for use with 1500-C globe

1465

Wire Lamp Guards and Wire Lamp Guard Grounding Kit

Wire Lamp Guards

Wire Lamp Guard Grounding Kit

Applications

Application

•	 Wire lamp guards with universal collars help prevent breakage
and theft.

Features
•	 A wide variety of types and sizes is available to fit your diverse
needs.
•	 Heavy-duty, 10 or 12 gauge, zinc-plated construction ensures
long life.
•	 Easy to install.
•	 Vinyl coated versions available.
•	 Rust-resistant zinc plating with chromate finish.
•	 Clamp type guards for vapor-tight fixtures available.
•	 Spot welded steel wire ensures long life.

•	 To ensure that your lamps are grounded, and comply with 	
NEC and OSHA requirements, the grounding kit supplies a
metal fastener and 1'/0.3 m wire to connect wire lamp guards 	
to a grounding circuit.

Certifications and Compliances
•	 Meets OSHA requirements
•	 Meets NEC requirements

Certifications and Compliances
•	 	Meets OSHA requirements
Wire Lamp Guards
Description

1.50/38.1

2100-2100-A

2200-2200-A

Vinyl coated GRIPON guards with out reflectors

1.50/38.1

V-2100BULK

V-2200BULK

PROTECTOR “O” guards; open bottom heavy-duty

1.50/38.1

1433

1434

Vinyl coated PROTECTOR “O” guards

1.50/38.1

V-1433

V-1434

—

2932

2933

Closed bottom wall and receptacle lamp guards

3.50/88.9

1438

—

Cage for utility light ➊

3.50/88.9

1435-6

—

1.69/0.51 — 2.63/0.8

1438-1

—

3.75/1.14 (1435-1)

1435-1

Guards for PAR and R-38 lamps
Guards for vapor-tight fixtures

1435-3 ➋

Wire Lamp Guard Grounding Kit
Description

Catalog Number
9995

Grounding Kit

Lighting

Catalog Number
for 100 W Bulb
for 200 W Bulb

GRIPON guards with out reflectors

Trap only to close bottom of 1433 and 1434

Lighting: McGill Lamp Protection

Collar Diameter
Inches/Millimeters

➊ See McGill Incandescent and Fluorescent Utility Lights.Plastic cages available, see McGill String-O-Lights.
➋ 300 Watt type PS25 lamp only.

1466

Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

Fluorescent Lamp Changers

Grips Lamp

Lighting

Lighting: McGill Lamp Changers

Applications
•	 Eliminate the need for climbing ladders and scaffolds.

Features
•	 Changers securely grip lamps for easy removal.
•	 Two models to choose from.
•	 	Models for spring-loaded, bi-pin, single-pin, or recessed double
contact lamps.

174

184
Catalog Number

Lamp Changers
Complete changer unit for up to 1—1/2”/38.1 mm diameter, 4’/1.2 m lamps that require 90˚ rotation or axial movement.	
Includes changer head, four zinc-plated steel pole sections each 24”/609.6 mm long, and starter changer.	
For T-8, T-10, T-12 single-pin, T-8, T-12 med. bi-pin, and T-10, T-12 recessed double contact lamps.

174

Complete changer unit for 1—1/2"/38.1 mm diameter, spring-loaded lamps up to 8'/2.4 m long.	
Includes changer head and two-section aluminum telescoping pole extending to 12—1/2’/3.8 m.

184

Accessories and Replacement Parts
170-P

Zinc-plated 2'/0.6 m steel pole section for 174
Zinc-plated steel changer head only for 174

171-C

Aluminum starter changer only for 174

173-S

Fluorescent changer pull cord only for 174

01540

Yellow driver, five clips, and speed nuts for 184

5274-1743

Changing Lamps is Easy With McGill Fluorescent Lamp Changers
1. First, angle changer to wedge yellow driver between lamp and socket. Then snap changer onto tube by rocking changer gently.
2. Next, standing at end of changer, push pole so driver will extract fluorescent lamp out of socket.
Model #184

Snap on Tube

Wedge In

Wedge driver between
lamp and socket.

Snap changer onto tube.
Rock changer onto lamp.

Push against
Spring and extract

Push against changer
spring and extract.

Lamp Identification
The changers featured on this page accommodate the fluorescent lamps at right.

Single-pin: T-8, T-10, T-12

Medium bi-pin: T-8, T-12

Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

Recessed double contact: T-10, T-12

1467

Incandescent Lamp Changers

Lighting: McGill Lamp Changers

Lighting

Rubber Covered Fingers with Garter Springs

Features
•	 Rubber covered fingers with garter springs make changing a 	
variety of lamp types simple.
•	 Hard-to-reach lamps are easily replaced without using ladders
or platforms.
•	 A variety of styles and sizes is available to fit practically all
commonly used lamps.
•	 Models for use with incandescent, mercury, metal halide, and
sodium lamps.
•	 Garter spring grips lamps firmly.
•	 	Lightweight for ease-of-use and convenience.
•	 	Insulated to help protect against shock.
•	 	Changes lamps up to 25’/7.6 m height (poles sold separately).

151-CA

153-C

161-C

Lamp Size ➊

Wattage

Catalog Number

Changer head with angle adjustment ➋

A-15, -17, -19; G-16-1/2,-18-1/2

15-100

150-CA

Changer head with angle adjustment ➋

A-19, -21, -23; P-25; PS-25, -30, -35;
FLE-20/T-19 ➌; SL-18 ➌; G-25, -30

25-500 (18 fluorescent ➌)

151-CA

Changer head only

PS-35, -40; G-40, -48

25-500

152-C

Changer head only

PS-52; G-48, -64

750-1500 (incandescent)

153-C

Changer head only

T-16, -18, -20

1000-1500 (incandescent)
400-1000 (mercury)

154-C

Changer head only

R-52, -57

500-1000 (incandescent flood)
400-750 (mercury)

155-C

Changer head only

R-30, -40; PAR-30, -36, -38; ER-30, -40

50-500 (incandescent)
100-175 (mercury)

156-C

Changer head only

E-37; BT-37, -46; ED-37

400-700 (mercury)
400-1000 (metal halide)

158-C

Changer head only

R-60

750 (incandescent)
400 (mercury flood)

159-C

Changer head only

E-21, -23, -23-1/2, -25, -28;
ED-23-1/2, -28; BT-28

75-250 (mercury)
175-400 (metal halide)
50-1000 (sodium)

161-C

Changer head only

E-17, -18; ED-17, -18; B-17

50 (mercury)
35-400 (sodium)
70-175 (metal halide)

163-C

Lamp Identification
A lamp designation consists of a letter indicating the shape and a figure to identify the approximate diameter in eighths of an inch. 	
Lamps are measured through their greatest diameter. G-25 lamps are globe shaped with a 3-1/8”/79.5 mm diameter.

SL18

P

G

A

T

PS

E/ED

BT

PAR

R

ER

➊ Lamp size, not Wattage, determines proper changer. May not accommodate weight of greater Wattage lamps.
➋ Jointed angle adapter for easy removal of horizontally or angle mounted lamps included. Use with small headed units only.
➌ Not for use with angle adapter.

1468

Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

Incandescent Lamp Changers

Rubber Suction Cups

Lighting

Lighting: McGill Lamp Changers

Features
•	 Rubber suction cups make it easy to change lamps where
space surrounding bulbs is limited.
•	 Made of durable synthetic rubber, these changers securely
fasten onto lamps and allow for safely changing lamps up to
25’/7.6 m heights (poles sold separately).
•	 For lamps with smooth face only.

157-C

162-C

166-C

Lamp Size *

Wattage

Catalog Number

Changer with rubber suction cups

R-40, -52, RB-52

75-1000 (incandescent spot/flood)
100-400 (mercury)

157-C

Changer with rubber suction cup

PAR-30, -36, -38

25-150 (incandescent)
75-100 (mercury)

162-C

Changer with rubber suction cup

R-20, -30, ER-30, PAR-20

30-75 (incandescent)

166-C

* Bulb size, not Wattage, determines changer to be used. Use on smooth surface lamps only.

Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

1469

Lighting: McGill Lamp Changers

Lighting

Lamp Changer Accessories and Replacement Parts

Application
•	 Lightweight accessories and replacement parts provide a safe
and sure way to remove and replace bulbs.

Features
•	 For use with incandescent lamp changers, these 5’/1.5 m
insulated, interchangeable pole sections are designed for quick
assembly to desired length. Up to four poles can be securely
locked together with spring-loaded buttons.
•	 Broken lamp base remover has plastic shield designed to catch
fragments and help protect user. Fits 160-P lamp changer pole,
providing a fully insulated, safe, and sure way to remove bases
of broken lamps.
200

9260

160-P

Catalog Number
Interchangeable, wood insulated steel pole, 5’/1.5 m sections

160-P

Broken lamp base remover for standard and mogul lamp bases

200

Garter springs for 150-CA, 151-CA, 154-C, 161-C changer heads

7013

Garter springs for 152-C, 153-C, 156-C, 158-C changer heads

7014

Garter springs for 155-C and 159-C changer heads

7019

Spring clip and button for lamp changer poles

9260

1470

Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

Notes

Lighting

Lighting: Notes

Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010

1471

Lighting: Notes

Lighting

Notes

1472

Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010



Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.6
Linearized                      : No
Encryption                      : Standard V4.4 (128-bit)
User Access                     : Print, Extract
Create Date                     : 2010:09:03 12:28:36-05:00
Creator                         : Adobe InDesign CS4 (6.0)
Modify Date                     : 2010:09:07 08:36:29-05:00
Trapped                         : False
XMP Toolkit                     : Adobe XMP Core 4.2.1-c043 52.372728, 2009/01/18-15:08:04
Metadata Date                   : 2010:09:07 08:36:29-05:00
Creator Tool                    : Adobe InDesign CS4 (6.0)
Format                          : application/pdf
Document ID                     : uuid:ee944a2f-6c96-4784-a8aa-a8401138a35b
Instance ID                     : uuid:01d7ee61-f656-43d5-a9d1-8209dc4af869
Producer                        : Adobe PDF Library 9.0
Page Layout                     : SinglePage
Page Mode                       : UseOutlines
Page Count                      : 562
EXIF Metadata provided by EXIF.tools

Navigation menu