Schneider Electric DIGEST 175 Terminal Blocks 101713 Catalog
2014-06-03
: Pdf 101713-Catalog 101713-Catalog 785901 Batch4 unilog
Open the PDF directly: View PDF
.
Page Count: 22
| Download | |
| Open PDF In Browser | View PDF |
Table of Contents Section 24 Terminal Blocks Track-Mounting Terminal Blocks & Prewired Connectors Advantys TELEFAST® 2 AB1RRN, p. 24-3 AB1AA, p. 24-10 ABE7 Connection Systems 24-22 NEMA Style Class 9080 Type G 24-13 IEC Style AB1 24-3 Direct-Mounting Terminal Blocks NEMA Style Class 9080 Type GK 24-13 Class 9080 Type GCB 24-17 GB2 24-17 Circuit Protectors AB1VV, p. 24-5 9080GR6, p. 24-13 Power Distribution Blocks (Splitter Blocks) Class 9080 Type LB 24-18 Panel Mounting Class 9080 Type FB 24-19 NEMA Style Class 9080 Type GF6 24-14 IEC Style AB1FU, AB1SF Fuseholders GB2, p. 24-17 9080GCB, p. 24-17 AB1AASF 24-8 24-10 AB1RRNSF 24-4 DF 24-8 Cable Ends (Ferrules, Wire Markers) 9080LB, p. 24-18 9080LBF, p. 24-18 DZ5 24-20 AZ5 24-20 AR1 24-21 AT1 24-21 9080GH (Square D) 24-16 9080MH (DIN) 24-12 Mounting Track 9080GF6, p. 24-14 TERMINAL BLOCKS 9080FB, p. 24-19 24 DZ5, p. 24-20 © 2009 Schneider Electric All Rights Reserved 24-1 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Selection Guide Terminal Blocks Refer to Catalog 9080CT9901R7/07 and 9080CT9601 www.schneider-electric.us Table 24.1: Product Family AB1RRN AB1VV AB1AA 9080G Type of product IEC spring technology IEC screw technology IEC insulation displacement technology NEMA screw technology Mounting DIN 3 DIN 1 and DIN 3 DIN 3 DIN 3 and Square D track a Maximum rated voltage (V) 600 600 600 600 b Maximum rated current per UL (A) 115 375 22 255 Ambient air temperature -40 to +266 °F (-40 to 130 °C) -40 to +257 °F (-40 to 125 °C) UL File 164359 CCN XCFR2 UL File 164359 CCN XCFR2 UL File 164359 CCN XCFR2 UL File E60616 CCN XCFR2 CSA File 702070 Class 6228 01 CSA File 702070 Class 6228 01 CSA File 702070 Class 6228 01 CSA File 025490 Class 3211 07 Gray Blue Green/Yellow Black Gray Blue Green/Yellow Orange Red Green White Black Gray Blue Green/Yellow Orange Red Approvals c Color a b c Natural (White) Black Blue Green Gray Orange Red Yellow Brown 9080GK6 can be mounted directly to a panel or on Square D track. 9080GT6 is 120 V. Refer to catalogs 9080CT9901 and 9080CT9601 for a complete list of certifications. 24 TERMINAL BLOCKS 24-2 CP5 Discount Schedule © 2009 Schneider Electric All Rights Reserved Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com IEC Style Terminal Blocks AB1RRN Spring Clip Blocks Refer to Catalog 9080CT9901R7/07 www.schneider-electric.us Table 24.2: Spring-Clip, AB1RRN Maximum Maximum Current Voltage b Description Spring-Clip Style Block Two Terminals 600 V Block End Barrierc $ Price Std. ea. Packa Color Catalog Number Gray AB1RRN235U2GR 1.40 Blue AB1RRN235U2BL Gray $ Price Std. ea. Packa Color Catalog Number 100 Gray AB1RRNAC242GR 0.60 10 1.40 100 Blue AB1RRNAC242BL 0.60 10 AB1RRN235U3GR 1.80 100 Gray AB1RRNAC243GR 0.68 10 Blue AB1RRN235U3BL 1.80 100 Blue AB1RRNAC243BL 0.68 10 Gray AB1RRN235U4GR 2.30 100 Gray AB1RRNAC244GR 0.75 10 Blue AB1RRN235U4BL 2.30 100 Blue AB1RRNAC244BL 0.75 10 Gray AB1RRN435U2GR 1.50 100 Gray AB1RRNAC442GR 0.60 10 Blue AB1RRN435U2BL 1.50 100 Blue AB1RRNAC442BL 0.60 10 Gray AB1RRN435U3GR 2.30 100 Gray AB1RRNAC443GR 0.60 10 Blue AB1RRN435U3BL 2.30 100 Blue AB1RRNAC443BL 0.60 10 Gray AB1RRN435U4GR 2.90 100 Gray AB1RRNAC444GR 0.90 10 Blue AB1RRN435U4BL 2.90 100 Blue AB1RRNAC444BL 0.90 10 Gray AB1RRN635U2GR 2.10 50 Gray AB1RRNAC642GR 0.83 10 Blue AB1RRN635U2BL 2.10 50 Blue AB1RRNAC642BL 0.83 10 Gray AB1RRN1035U2GR 2.70 50 Gray AB1RRNAC1042GR 0.90 10 Blue AB1RRN1035U2BL 2.70 50 Blue AB1RRNAC1042BL 0.90 10 Gray AB1RRN1635U2GR 4.40 50 Gray AB1RRNAC1642GR 1.20 10 Blue AB1RRN1635U2BL 4.40 50 Blue AB1RRNAC1642BL 1.20 10 Gray AB1RRN3535U2GR 22.50 10 Blue AB1RRN3535U2BL 22.50 10 20 A Solid or Stranded Copper Wire 22–12 AWG 5 mm (0.20 in.) wide Spring-Clip Style Block Three Terminals 600 V 20 A Solid or Stranded Copper Wire 22–12 AWG 5 mm (0.20 in.) wide Spring-Clip Style Block Four Terminals 600 V 20 A Solid or Stranded Copper Wire 22–12 AWG 5 mm (0.20 in.) wide Spring-Clip Style Block Two Terminals 600 V 30 A Solid or Stranded Copper Wire 24–10 AWG 6 mm (0.24 in.) wide Spring-Clip Style Block Three Terminals 600 V 30 A Solid or Stranded Copper Wire 24–10 AWG 6 mm (0.24 in.) wide Spring-Clip Style Block Four Terminals 600 V 30 A Solid or Stranded Copper Wire 24–10 AWG 6 mm (0.24 in.) wide Spring Clip Style Block Two Terminals 600 V 50 A Solid or Stranded Copper Wire 24–8 AWG 8 mm (0.31 in.) wide Spring Clip Style Block Two Terminals 600 V 60 A Solid or Stranded Copper Wire 16–6 AWG 10 mm (0.39 in.) wide Spring Clip Style Block Two Terminals 600 V 85 A Solid or Stranded Copper Wire 16–4 AWG Spring Clip Style Block Two Terminals Solid or Stranded Copper Wire 14–2 AWG 600 V 115 A None Required 16 mm (0.63 in.) wide a b c Orders must specify the standard package quantity (Std. Pack) or multiples of that quantity. These maximum current values assume the use of insulated copper conductors with 75oC temperature rating and are calculated based on NEC Article 310, Table 310-16. In most cases this value is the maximum ampacity of the wire which has the greatest current carrying capacity. The actual allowable current for a particular application depends on the size, insulation class, and other characteristics of the wire used. The UL ratings are shown. The CSA rating may be higher or lower. Refer to the catalog for CSA ratings. One end-barrier is required for each assembly of like blocks. File CCN E164359 XCFR2 File Class 702070 6228 01 TERMINAL BLOCKS 12 mm (0.47 in.) wide RoHS Compliant 24 For track and accessories, see pages 24-11 and 24-12. © 2009 Schneider Electric All Rights Reserved CP5 Discount Schedule 24-3 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com IEC Style Terminal Blocks AB1RRN Spring Clip Terminals, AB1VV and AB1TP Miniature Blocks www.schneider-electric.us Refer to Catalog 9080CT9901R7/07 Table 24.3: Spring-Clip, AB1RRN (continued) Description Spring-Clip Style Grounding Block Two Terminals End Barrier c Block Maximum Voltage Maximum Current b Color Catalog Number 600 V 20 A Green / Yellow AB1RRNTP235U2 5.10 600 V 20 A Green / Yellow AB1RRNTP235U4 600 V 30 A Green / Yellow 600 V 50 A 600 V $ Price Std. Pack a ea. $ Price Std. Pack a ea. Color Catalog Number 100 Green AB1RRNTPAC242 0.60 10 7.50 100 Green AB1RRNTPAC244 0.75 10 AB1RRNTP435U2 6.20 100 Green AB1RRNTPAC242 0.60 10 Green / Yellow AB1RRNTP635U2 6.90 50 Green AB1RRNTPAC642 0.83 10 60 A Green / Yellow AB1RRNTP1035U2 7.80 50 Green AB1RRNTPAC1042 0.90 10 600 V 85 A Green / Yellow AB1RRNTP1635U2 9.30 50 Green AB1RRNTPAC1642 1.20 10 300 V 10 A Gray AB1RRNSF435UGR 4.10 100 0.60 10 Gray AB1SF520 AB1SF520B AB1SF520M AB1SV1 AB1SV2 6.50 20.30 20.30 6.20 15.60 100 100 100 100 100 Gray AB1VV215 1.50 100 AB1AC2 0.62 10 Solid or Stranded Copper Wire 22–12 AWG 5 mm (0.20 in.) wide Spring-Clip Style Grounding Block Four Terminals 5 mm (0.20 in.) wide Solid or Stranded Copper Wire 22–12 AWG Spring-Clip Style Grounding Block Two Terminals Solid or Stranded Copper Wire 22–10 AWG 6 mm (0.24 in.) wide Spring-Clip Style Grounding Block Two Terminals Solid or Stranded Copper Wire 24–8 AWG 8mm (0.31 in.) wide Spring-Clip Style Grounding Block Two Terminals Solid or Stranded Copper Wire 16–6 AWG 10 mm (0.39 in.) wide Spring-Clip Style Grounding Block Two Terminals Solid or Stranded Copper Wire 22–10 AWG 12 mm (0.47 in.) wide Spring-Clip Style Diode/Fuseholder Block 6 mm (0.24 in.) wide Table 24.4: Solid or Stranded Copper Wire 22–10 AWG Fuseholder 5x20 (Fuse not included) Fuseholder 5x20 + 24 V LED Fuseholder 5x20 + 220 V LED Holder for Diode (Diode not included) Holder with1N4007-1 Diode Depends on fuse or diode used Gray AB1RRNAC442GR Not applicable Miniature, AB1VV and AB1TP Miniature Block with Box Lug Solid or Stranded Copper Wire 22–14 AWG 5 mm (0.20 in.) wide 150 V Gray 10 A Mounts on 15 mm DIN 2 track Blue AB1VV215BL 1.50 100 Blue 24 Miniature Block with Box Lug Solid or Stranded Copper Wire 22–10 AWG 150 V 10 A Gray AB1VV415 1.70 100 Gray AB1AC2 0.62 10 150 V 10 A Green / Yellow AB1TP215 4.40 100 Gray AB1CT215 0.62 50 Mounts on 15 mm DIN 2 track 5 mm (0.20 in.) wide TERMINAL BLOCKS Miniature Grounding Block with Box Lug Solid or Stranded Copper Wire 22–14 AWG Mounts on 15 mm DIN 2 track 6 mm (0.24 in.) wide a Orders must specify the standard package quantity (Std. Pack) or multiples of that quantity. b These maximum current values assume the use of insulated copper conductors with 75oC temperature rating and are calculated based on NEC article 310, Table 310-16. In most cases this value is the maximum ampacity of the wire which has the greatest current carrying capacity. The actual allowable current for a particular application depends on the size, insulation, class and other characteristics of the wire used. The UL ratings are shown. The CSA rating may be higher or lower. Refer to the catalog for CSA ratings. c One end-barrier is required for each assembly of like blocks. File CCN 24-4 E164359 XCFR2 File Class 702070 6228 01 For track and accessories, see pages 24-11 and 24-12. RoHS Compliant CP5 Discount Schedule © 2009 Schneider Electric All Rights Reserved Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com IEC Style Terminal Blocks AB1VV Box Lug Blocks Refer to Catalog 9080CT9901R7/07 www.schneider-electric.us Table 24.5: Box Lug, AB1VV Maximum Voltage Description Maximum Current b End Barrier c Block $ Price Std. ea. Pack a Color Catalog Number Gray AB1VV235U 1.40 Blue AB1VV235UBL Orange $ Price Std. ea. Pack a Color Catalog Number 100 Gray AB1AC24 0.62 50 1.40 100 Blue AB1AC24BL 0.62 50 AB1VV235UGE 1.40 100 Orange AB1AC24GE 0.62 50 Gray AB1VV435U 1.50 100 Gray AB1AC24 0.62 50 Blue AB1VV435UBL 1.50 100 Blue AB1AC24BL 0.62 50 Orange AB1VV435UGE 1.50 100 Orange AB1AC24GE 0.62 50 Black AB1VV435UNO 1.50 100 Gray AB1AC24 0.62 50 Red AB1VV435URO 1.50 100 Gray AB1AC24 0.62 50 Green AB1VV435UVE 1.50 100 Gray AB1AC24 0.62 50 White AB1VV435UBLA 1.50 100 Gray AB1AC24 0.62 50 Gray AB1VV635U 2.10 100 Gray AB1AC6 0.62 50 Blue AB1VV635UBL 2.10 100 Blue AB1AC6BL 0.62 50 Orange AB1VV635UGE 2.10 100 Orange AB1AC6GE 0.62 50 Gray AB1VVN1035U 2.70 50 Gray AB1ACN10 0.78 10 Blue AB1VVN1035UBL 2.70 50 Blue AB1ACN10BL 0.78 10 Gray AB1VVN1635U 5.40 50 Gray AB1ACN16 0.93 10 Blue AB1VVN1635UBL 5.40 50 Blue AB1ACN16BL 0.93 10 Gray AB1VVN3535U 7.70 20 Box-Lug Style Block 600 V Solid or Stranded Copper Wire 22–12 AWG 20 A 5 mm (0.20 in.) wide Box-Lug Style Block 600 V Solid or Stranded Copper Wire 22–10 AWG 30 A 6 mm (0.24 in.) wide Box-Lug Style Block 600 V Solid or Stranded Copper Wire 22–8 AWG 50 A 8 mm (0.31 in.) wide Box-Lug Style Block 600 V Solid or Stranded Copper Wire 16–6 AWG 65 A 10 mm (0.39 in.) wide Box-Lug Style Block 600 V Solid or Stranded Copper Wire 12–4 AWG 85 A 12 mm (0.47 in.) wide Box-Lug Style Block 600 V Solid or Stranded Copper Wire 10–2 AWG 95 A Not required for these blocks. Blue AB1VVN3535UBL 7.70 20 Gray AB1VVN7035U 27.90 20 16 mm (0.63 in.) wide Box-Lug Style Block 600 V Solid or Stranded Copper Wire 6–2/0 AWG 175 A Not required for these blocks. Blue AB1VVN7035UBL 27.90 20 Gray AB1VVN15035U 65.00 10 24 mm (0.94 in.) wide Box-Lug Style Block Solid or Stranded Copper Wire 2/0–350 kcmil 335 A Not required for these blocks. Blue AB1VVN15035UBL 65.00 10 28 mm (1.10 in.) wide a b c Orders must specify the standard package quantity (Std. Pack) or multiples of that quantity. These maximum current values assume the use of insulated copper conductors with 75oC temperature rating and are calculated based on NEC Article 310, Table 310-16. In most cases this value is the maximum ampacity of the wire which has the greatest current carrying capacity. The actual allowable current for a particular application depends on the size, insulation class, and other characteristics of the wire used. The UL rating are shown. The CSA rating may be higher or lower. Refer to the catalog for CSA ratings. One end-barrier is required for each assembly of like blocks. File CCN E164359 XCFR2 File Class 702070 6228 01 RoHS Compliant CP5 24 For track and accessories, see pages 24-11 and 24-12. © 2009 Schneider Electric All Rights Reserved TERMINAL BLOCKS 600 V Discount Schedule 24-5 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com IEC Style Terminal Blocks AB1TP Grounding and AB1ET Two Tier Blocks Refer to Catalog 9080CT9901R7/07 www.schneider-electric.us Table 24.6: Grounding, AB1TP Description End Barrier c Block Maximum Voltage Color Catalog Number 600 V Green/Yellow AB1TP235U 5.30 100 600 V Green/Yellow AB1TP435U 6.20 100 Not required for this block. 600 V Green/Yellow AB1TP635U 6.90 100 Not required for this block. 600 V Green/Yellow AB1TP1035U 7.80 50 Not required for this block. 600 V Green/Yellow AB1TP1635U 9.30 50 Not required for this block. 600 V Green/Yellow AB1TP3535U 13.20 20 Not required for this block. $ Price Std. Pack a ea. Color Catalog Number Green AB1AC25 $ Price Std. Pack a ea. Grounding Block Solid or Stranded Copper Wire 22–10 AWG 0.83 10 5.1 mm (0.20 in.) wide Grounding Block Solid or Stranded Copper Wire 22–10 AWG 6 mm (0.24 in.) wide Grounding Block Solid or Stranded Copper Wire 22–8 AWG 8 mm (0.31 in.) wide Grounding Block Solid or Stranded Copper Wire 16–6 AWG 10 mm (0.39 in.) wide Grounding Block Solid or Stranded Copper Wire 12–4 AWG 12 mm (0.47 in.) wide Grounding Block Solid or Stranded Copper Wire 10–2 AWG 16 mm (0.63 in.) wide Table 24.7: Two Tier, AB1ET End Barrier c Block Description 24 a b TERMINAL BLOCKS c Color Catalog Number $ Price ea. 4.10 Std. Pack a Color Catalog Number $ Price ea. Std. Pack a Standard two tier block Gray AB1ET435U 100 Standard two tier block Black AB1ET435U2 6.20 100 + upper-lower link Standard two tier block Green/Yellow AB1ET435UTP 18.60 100 + grounding Standard two tier block Red AB1ET435UBRO 17.10 100 + red 24 V LED Standard two tier block Red AB1ET435UBVE 17.10 100 + green 24 V LED Gray AB1TE 1.10 50 Standard two tier block Orange AB1ET435UBGE 17.10 100 + head to tail diodes (red) 6 mm (0.24 in.) wide Two Tier Blocks Standard two tier block Red AB1ET435UHBRO 10.80 100 Solid or Stranded + diode upper-lower Copper Wire Standard two tier block 22–10 AWG Orange AB1ET435UBHGE 10.80 100 + diode lower-upper 300 V 20 A b Standard two tier block Red AB1ET435U2DRO 19.20 100 + 2 diodes Orders must specify the standard package quantity (Std. Pack) or multiples of that quantity. o These maximum current values assume the use of insulated copper conductors with 75 C temperature rating and are calculated based on NEC Article 310, Table 310-16. In most cases this value is the maximum ampacity of the wire which has the greatest current carrying capacity. The actual allowable current for a particular application depends on the size, insulation class, and other characteristics of the wire used. The UL ratings are shown. The CSA rating may be higher or lower. Refer to the catalog for CSA ratings. One end-barrier is required for each assembly of like blocks. File CCN E164359 XCFR2 File Class 702070 6228 01 RoHS Compliant For track and accessories, see pages 24-11 and 24-12 24-6 CP5 Discount Schedule © 2009 Schneider Electric All Rights Reserved Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com IEC Style Terminal Blocks AB1DD, AB1ET Three Tier and AB1ETN Two Tier Blocks Refer to Catalog 9080CT9901R7/07 www.schneider-electric.us Table 24.8: Three Tier, AB1DD and AB1ET Maximum Voltage Description End Barrier c Block Maximum Currentb Color Catalog Number $ Price Std. Pack ea. a Color Catalog Number $ Price ea. Std. Pack a Three Tier Block Solid or Stranded Copper Wire 22–12 AWG Three Tier Block with 24 V LED (+) Gray Solid or Stranded Copper Wire 22–12 AWG Three Tier Block with 24 V LED (-) 6 mm (0.24 in.) wide Solid or Stranded Copper Wire 22–12 AWG Three Tier Block with 24 V LED (-) and ground 100 AB1DDP235ULP 10.10 100 AB1DDP235ULM 10.10 100 AB1DDP235T 8.60 100 13.20 100 Gray with Green/Yellow AB1DDP235TLP 300 V 25 A Not required for these blocks. AB1DDP235TLM 13.20 100 AB1ET3235U 8.60 100 AB1ET3235UTLP 27.80 100 Gray with Green/Yellow AB1ET3235UTLM 27.80 100 12.60 100 Solid or Stranded Copper Wire 22–12 AWG Three Tier Block Gray Solid or Stranded Copper Wire 22–12 AWG Three Tier Block with 24 V LED (+) and ground 6 mm (0.24 in.) wide 5.40 Solid or Stranded Copper Wire 22–12 AWG Three Tier Block with ground Solid or Stranded Copper Wire 22–12 AWG Three Tier Block with 24 V LED (+) and ground 6 mm (0.24 in.) wide AB1DDP235U Solid or Stranded Copper Wire 22–12 AWG Three Tier Block with 24 V LED (-) and ground Solid or Stranded Copper Wire 22–12 AWG Three Tier Block with ground AB1ET3235UT Solid or Stranded Copper Wire 22–12 AWG Table 24.9: Two Tier, AB1ETN Maximum Voltage Description Maximum Current b End Barrier c Block Color Catalog Number $ Price Std. Pack ea. a Gray AB1ETN335U 3.60 Gray AB1ETN435U 5.10 Color Catalog Number $ Price ea. Std. Pack a 100 Gray AB1TEN3 1.10 10 100 Gray AB1TEN4 1.20 10 Two Tier Block (one terminal in and two out) Solid or Stranded Copper Wire 22–10 AWG Two Tier Block (two terminals in and two out) 300 V AB1ETN335U Green/ AB1ETNTP435U 12.20 100 Not required for this block. Yellow Solid or Stranded Copper Wire 22–10 AWG a Orders must specify the standard package quantity (Std. Pack) or multiples of that quantity. b These maximum current values assume the use of insulated copper conductors with 75oC temperature rating and are calculated based on NEC Article 310, Table 310-16. In most cases this value is the maximum ampacity of the wire which has the greatest current carrying capacity. The actual allowable current for a particular application depends on the size, insulation class, and other characteristics of the wire used. The UL ratings are shown. The CSA rating may be higher or lower. Refer to the catalog for CSA ratings. c One end-barrier is required for each assembly of like blocks. File CCN E164359 XCFR2 File Class 702070 6228 01 RoHS Compliant TERMINAL BLOCKS 6 mm (0.24 in.) wide 30 A Solid or Stranded Copper Wire 22–10 AWG Grounding Block (two terminals in and two out) 24 For track and accessories, see pages 24-11 and 24-12. © 2009 Schneider Electric All Rights Reserved CP5 Discount Schedule 24-7 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com IEC Style Terminal Blocks DF, AB1FU and AB1SF/SV Fuseholders Refer to Catalogs 9080CT9901R7/07 and 9080CT0801 www.schneider-electric.us Table 24.10: Fuse Block, AB1d End Barrier c Block Description Fuse Block For 5x20 or 5x25 mm fuse Solid or Stranded Copper Wire 22–10 AWG 8 mm (0.31 in.) wide Maximum Voltage—600 V Maximum Current—15 A b Fuse Block For 1/4 x 1-1/4 in. fuse Solid or Stranded Copper Wire 22–10 AWG 10 mm (0.39 in.) wide Maximum Voltage—600 V Maximum Current—15 A b Fuse Block For 5 x 20 mm fuse 12 mm (0.47 in.) wide Without indicator lamp $ Price ea. Color Catalog Number Std. Pack a Gray AB1FUSE435U5X 7.80 100 With 5–12 V LED indicator Gray AB1FUSE435U5XJ 16.10 50 With 12–24 V LED indicator Gray AB1FUSE435U5XB 16.10 50 With 110–250 V neon indicator Gray AB1FUSE435U5XM 16.10 50 Without indicator lamp Gray AB1FUSE435U6X 14.40 100 With 5–12 V LED indicator Gray AB1FUSE435U6XJ 18.60 50 With 12–24 V LED indicator Gray AB1FUSE435U6XB 18.60 50 With 110–250 V neon indicator Gray AB1FUSE435U6XM 18.60 50 $ Price ea. Std. Pack a Not required for these blocks. Not required for these blocks. Without indicator lamp Gray AB1FU10135U 10.80 50 Solid or Stranded Copper Wire 22–6 AWG With 28 V yellow LED indicator Gray AB1FU10135UB 26.40 50 Maximum Voltage—600 V Maximum Current—15 A b Fuse Block For 5 x 25 mm fuse With 250 V yellow LED indicator Gray AB1FU10135UU 26.40 50 Without indicator lamp Gray AB1FU10235U 14.00 Solid or Stranded Copper Wire 22–6 AWG Without indicator lamp Gray AB1FU10335U Maximum Voltage—600 V Maximum Current—15 A b Fuse Block For 1/4 x 1-1/4 in. fuse Without indicator lamp Gray With 28 V yellow LED indicator With 110–500 V red neon indicator Solid or Stranded Copper Wire 22–6 AWG Catalog Number Color Gray AB1TF 1.40 50 50 Gray AB1TF 1.40 50 15.60 50 Gray AB1TF 1.40 50 AB1FU10435U 15.60 50 Gray AB1FU10435UB 26.40 50 Gray AB1TF 1.40 50 Gray AB1FU10435UFS 26.40 50 Maximum Voltage—600 V Maximum Current—15 A b Fuse Block For 5 x 30 mm fuse Solid or Stranded Copper Wire 22–6 AWG Maximum Voltage—600 V Maximum Current—15 A b Fuse / Diode block Gray AB1SF435U 3.90 100 Gray AB1PS4 0.86 10 Removable fuse holder Gray AB1SF520 6.50 100 for 5x20 mm fuse Removable fuse holder Fuse / Diode Block for 5x20 mm fuse Gray AB1SF520B 20.30 100 with 24 V red LED indicator Solid or Stranded Copper Wire 22–10 AWG Removable fuse holder N/A for 5x20 mm fuse Gray AB1SF520M 20.30 100 Maximum Voltage—300 V with 220 V red LED indicator Maximum Current—10 A b Removable diode Gray AB1SV1 6.20 100 or resistor holder 6 mm (0.24 in.) wide Removable holder Gray AB1SV2 15.60 100 With 1N4007.1 diode a Orders must specify the standard package quantity (Std. Pack) or multiples of that quantity. b These maximum current values assume the use of insulated copper conductors with 75oC temperature rating and are calculated based on NEC Article File E164359 310, Table 310-16. In most cases this value is the maximum ampacity of the wire which has the greatest current carrying capacity. The actual allowable CCN XCFR2 current for a particular application depends on the size, insulation class, and other characteristics of the wire used. The UL ratings are shown. The CSA rating may be higher or lower. Refer to the catalog for CSA ratings. File 702070 c One end-barrier is required for each assembly of like blocks. Class 6228 01 d For additional information, refer to Catalog 9080CT9901 RoHS Compliant Table 24.11: Modular Fuse Holders, DFe 24 Rated Thermal Current TERMINAL BLOCKS 30 A DFCC1V File E310269 CNN IZLT e f 24-8 Type of Fuse Composition Standard Pack Quantity Catalog Number $ Price ea. 1 Pole 12 DFCC1 18.00 2 Poles 6 DFCC2 36.00 3 Poles 4 DFCC3 54.00 1 Pole f 12 DFCC1V 22.50 2 Poles f 6 DFCC2V 45.00 3 Poles f 4 DFCC3V 68.00 Class CC DFCC3V For additional blocks and information, refer to Catalog 9080CT0801. With blown-fuse indicator. CP5 Discount Schedule © 2009 Schneider Electric All Rights Reserved Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com IEC Style Terminal Blocks AB1 Other Blocks Refer to Catalog 9080CT9901R7/07 www.schneider-electric.us Table 24.12: Other Blocks, AB1 Block Description End Barrierc $ Price ea. Std. Pack a Color Catalog Number Gray AB1D11435U 12.50 50 With no test sockets Gray AB1SC435U 7.10 50 With two test sockets Gray AB1SC435U2PT 7.10 50 Gray AB1FV135U 3.00 Gray AB1FC335U Gray AB1FF235U Catalog Number Color $ Price ea. Std. Pack a Block for Diodes (Diodes not included) Not required for this block. Solid or Stranded Copper Wire 22–14 AWG 12 mm (0.47 in.) wide Circuit Isolation Block Solid or Stranded Copper Wire 22–10 AWG 6 mm (0.24 in.) wide Maximum Voltage—600 V Maximum Current—20 Ab Box Lug / Slip-on Block Solid or Stranded Copper Wire 22–12 AWG 6 mm (0.24 in.) wide Table 24.13: Maximum Voltage—300 V Maximum Current—10 Ab Box lug on one side. Slip-on access from top and side Box lug on one side. Slip-on access from top Slip-on connectors on both sides Gray AB1PS4 0.86 10 100 Gray AB1TC01 1.40 50 3.90 100 Gray AB1TC3 1.40 50 2.10 100 Not required for this block. Lug/Lug and Lug/Clamp, AB1 Block Description Lug/Lug Block Solid or Stranded Copper Wire 0 AWG–350 kcmil Partition $ Price ea. Std. Pack a Color Catalog Number $ Price ea. Std. Pack a Color Catalog Number M10 bolt Maximum Voltage—600 V Maximum Current—230 Ab Gray AB1BB9535 21.30 10 Gray AB1CT1 2.40 50 M12 bolt Maximum Voltage—600 V Maximum Current—375 Ab Gray AB1BB18535 27.30 10 Gray AB1CT2 2.70 50 M12 bolt Maximum Voltage—600 V Maximum Current—375 Ab Gray AB1BB24035 45.00 10 Gray AB1CT2 2.70 50 M10 bolt Maximum Voltage—600 V Maximum Current—230 Ab Gray AB1BC9535 31.10 10 Gray AB1CT1 2.40 50 M12 bolt Maximum Voltage—600 V Maximum Current—325 Ab Gray AB1BC15035 62.00 10 Gray AB1CT2 2.70 50 M12 bolt Maximum Voltage—600 V Maximum Current—375 Ab Gray AB1BC24035 86.00 10 Gray AB1CT2 2.70 50 32 mm (1.26 in.) wide Lug/Lug Block Solid or Stranded Copper Wire 0 AWG– 400 kcmil 42 mm (1.65 in.) wide Lug/Lug Block Solid or Stranded Copper Wire 0 AWG–500 kcmil 42 mm (1.65 in.) wide Lug/Clamp Block Solid or Stranded Copper Wire 0 AWG–350 kcmil 32 mm (1.26 in.) wide Lug/Clamp Block Solid or Stranded Copper Wire 0 AWG–400 kcmil 42 mm (1.65 in.) wide Lug/Clamp Block Solid or Stranded Copper Wire 0 AWG–500 kcmil a b c Orders must specify the standard package quantity (Std. Pack) or multiples of that quantity. These maximum current values assume the use of insulated copper conductors with 75oC temperature rating and are calculated based on NEC Article 310, Table 310-16. In most cases this value is the maximum ampacity of the wire which has the greatest current carrying capacity. The actual allowable current for a particular application depends on the size, insulation class, and other characteristics of the wire used. The UL ratings are shown. The CSA rating may be higher or lower. Refer to the catalog for CSA ratings. One end-barrier is required for each assembly of like blocks. File CCN E164359 XCFR2 File Class 702070 6228 01 RoHS Compliant 24 For track and accessories, see pages 24-11 and 24-12. TERMINAL BLOCKS 42 mm (1.65 in.) wide © 2009 Schneider Electric All Rights Reserved CP5 Discount Schedule 24-9 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com IEC Terminal Blocks AB1AA Insulation Displacement Blocks Refer to Catalog 9080CT9901R7/07 www.schneider-electric.us Insulation Displacement Style Terminal Blocks and Accessories • • • • Insert wires without stripping Available for wire sizes 30-14 AWG DIN 3 rail mounting Finger safe connections 5 mm (0.20 in.) wide AB1AA135U4•• Table 24.14: Insulation Displacement, AB1AA Description Insulation Displacement Connector: Passthrough Block Solid or Stranded Copper Wire 5 mm (0.20 in.) wide AB1AA135U2•• Insulation Displacement Connector: Grounding Block Block Maximum Maximum Voltage Currentb Wire Size No. of Poles 600 V 13 A 30–18 AWG 2 600 V 13 A 18–14 AWG 2 600 V 10 A 30–18 AWG 3 600 V 10 A 18–14 AWG 3 600 V 10 A 30–18 AWG 4 600 V 10 A 18–14 AWG 4 Two Tier Block Catalog Number Gray Blue Gray Blue Gray Blue Gray Blue Gray Blue Gray AB1AA135U2GR AB1AA135U2BL AB1AA235U2GR AB1AA235U2BL AB1AA135U3GR AB1AA135U3BL AB1AA235U3GR AB1AA235U3BL AB1AA135U4GR AB1AA135U4BL AB1AA235U4GR Blue AB1AA235U4BL $ Price Std. ea. Packa 1.80 100 1.80 100 2.00 100 2.00 100 2.90 50 2.90 50 3.00 50 3.00 50 5.90 50 5.90 50 6.00 100 6.00 $ Price Std. ea. Packa .62 10 .62 10 .62 10 .62 10 .78 10 .78 10 .78 10 .78 10 .93 10 .93 10 .93 10 Color Catalog Number Gray Blue Gray Blue Gray Blue Gray Blue Gray Blue Gray AB1AAAC122GR AB1AAAC122BL AB1AAAC122GR AB1AAAC122BL AB1AAAC123GR AB1AAAC123BL AB1AAAC123GR AB1AAAC123BL AB1AAAC124GR AB1AAAC124BL AB1AAAC124GR 100 Blue AB1AAAC124BL .93 AB1AAAC122VE .62 10 10 10 10 10 600 V 13 A 30–18 AWG 2 Green/ Yellow 600 V 13 A 18–14 AWG 2 AB1AATP235U2 6.20 100 600 V 13 A 30–18 AWG 2 AB1AATP135U3 8.10 100 600 V 10 A 18–14 AWG 3 AB1AATP235U3 8.10 50 600 V 10 A 30–18 AWG 4 Green/ Yellow Green/ Yellow Green/ Yellow Green/ Yellow AB1AATP135U4 13.70 50 Green/ Yellow Green/ Yellow Green/ Yellow Green/ Yellow AB1AAAC124VE .93 10 600 V 10 A 18–14 AWG 4 Green/ Yellow AB1AATP235U4 14.00 50 Green/ Yellow AB1AAAC124VE .93 10 600 V 13 A 30–18 AWG 5 mm (0.20 in.) wide AB1AATP135U3 End Barrierc Color 600 V 22 A 18–14 AWG 6 mm (0.24 in.) wide AB1AAET235•• AB1AATP135U2 5.90 100 Green/ Yellow AB1AAAC122VE .62 AB1AAAC123VE .78 10 AB1AAAC123VE .78 10 2 Gray AB1AAET135UGR 4.80 50 Gray AB1AAAC124GR .93 10 2/2 Gray AB1AAET235UGR 5.10 50 Gray AB1AAAC124GR .93 10 2/2 Red AB1AAET235URO 5.10 50 Red AB1AAAC124GR .93 10 2/2 Orange AB1AAET235UGE 5.10 50 Orange AB1AAAC124GR .93 10 4 Red AB1AAET235UBRO 15.60 50 Red AB1AAAC124GR .93 10 4 Orange AB1AAET235UBGE 15.60 50 Orange AB1AAAC124GR .93 10 Fuse Block 600 V 6.3 A 30–18 AWG 2 Gray AB1AASF135UGR 5.00 50 Gray AB1AAAC123GR .78 10 6 mm (0.24 in.) wide 600 V 6.3 A 18–14 AWG 2 Gray AB1AASF235UGR 5.30 50 Gray AB1AAAC123GR .78 10 Disconnect Block 600 V AB1AASF135U•• 24 a b c Gray AB1AASC235UGR 6.00 50 Gray AB1AAAC123GR .78 10 Blue AB1AASC235UBL 6.00 50 Blue AB1AAAC123BL .78 10 Orders must specify the standard package quantity (Std. Pack) or multiples of that quantity. o These maximum current values assume the use of insulated copper conductors with 75 C temperature rating and are calculated based on NEC Article 310, Table 310-16. In most cases this value is the maximum ampacity of the wire which has the greatest current carrying capacity. The actual allowable current for a particular application depends on the size, insulation class, and other characteristics of the wire used. One end-barrier is required for each assembly of like blocks. 10 A 18–14 AWG TERMINAL BLOCKS File CCN E164359 XCFR2 2 File Class 702070 6228 01 RoHS Compliant For track and accessories, see pages 24-11 and 24-12. CP5 24-10 Discount Schedule © 2009 Schneider Electric All Rights Reserved Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com IEC Style Terminal Blocks AB1 Markers Refer to Catalog 9080CT9901R7/07 www.schneider-electric.us Table 24.15: Markers, AB1 Marking Catalog Number $ Price Std. ea. Pack a 1 Blank AB1BV5 1–10 AB1B510 11–20 AB1B520 21–30 AB1B530 31–40 AB1B540 41–50 AB1B550 0.78 25 AB1B510 51–60 AB1B560 61–70 AB1B570 Black number on 71–80 AB1B580 white background 81–90 AB1B590 5 mm (0.20 in.) wide 91–100 AB1B5100 Blank AB1BV6 1–10 AB1B610 11–20 AB1B620 21–30 AB1B630 31–40 AB1B640 41–50 AB1B650 51–60 AB1B660 61–70 AB1B670 0.78 25 71–80 AB1B680 AB1B610 81–90 AB1B690 91–100 AB1B6100 Black number on L1 AB1B6L1 white background 6 mm (0.24 in.) wide L2 AB1B6L2 L3 AB1B6L3 + (Red) AB1BV6RP – (Blue) AB1BV6BM Blank AB1BV8 1–10 AB1B810 11–20 AB1B820 21–30 AB1B830 31–40 AB1B840 0.78 25 41–50 AB1B850 AB1B810 51–60 AB1B860 61–70 AB1B870 Black number on 71–80 AB1B880 white background 81–90 AB1B890 8 mm (0.31 in.) wide 91–100 AB1B8100 Blank AB1RV 1 AB1R1 2 AB1R2 3 AB1R3 4 AB1R4 2 2 2 5 AB1R5 2 2 2 2 2 6 AB1R6 2 2 0.78 25 7 AB1R7 AB1R2 8 AB1R8 9 AB1R9 Black number or symbol 0 AB1R0 on white background 0–9 AB1R11 + AB1R12 – AB1R13 a Orders must specify the standard package quantity (Std. Pack) or multiples of that quantity. Catalog Marking Number 2 3 4 5 6 7 8 10 9 A A A A A A A A A A AB1GA 1 2 3 4 5 Black capital letters on white background 6 7 8 10 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z $ Price Std. ea. Pack a 0.78 25 AB1SR6 0.78 200 AB1SA1 0.18 500 AB1SA2 0.39 500 AB1SA3 0.78 500 AB1RT 0.78 500 AR1SB2 1.50 100 AR1SB3 1.35 50 1 AB1GA AB1GB AB1GC AB1GD AB1GE AB1GF AB1GG AB1GH AB1GI AB1GJ AB1GK AB1GL AB1GM AB1GN AB1GO AB1GP AB1GQ AB1GR AB1GS AB1GT AB1GU AB1GV AB1GW AB1GX AB1GY AB1GZ 2 3 4 5 6 7 8 10 9 24 TERMINAL BLOCKS RoHS Compliant © 2009 Schneider Electric All Rights Reserved CP5 Discount Schedule 24-11 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com IEC Style Terminal Blocks Mounting Track and End Clamps Refer to Catalog 9080CT9901 www.schneider-electric.us Table 24.16: DIN 3 Track – Various Lengths Table 24.17: $ Price Std.a ea. Pack 0.08 (3) MH203 3.20 0.10 (4) MH204 3.60 0.13 (5) MH205 4.10 0.15 (6) MH206 4.70 0.18 (7) MH207 5.10 0.20 (8) MH208 5.60 0.23 (9) MH209 6.20 0.25 (10) MH210 6.80 Galvanized 0.28 (11) MH211 7.20 steel, 0.30 (12) MH212 7.80 no mounting 0.33 (13) MH213 8.30 holes 0.36 (14) MH214 8.70 0.38 (15) MH215 9.30 0.41 (16) MH216 9.80 0.42 (17) MH217 10.20 0.46 (18) MH218 10.80 0.50 (19.68) MH220 11.60 Symmetrical rail 1 (39.37) MH239 19.70 35 x 7.5 mm 2 (78.74) MH279 29.60 (1.38 in. x 0.295 in.) 10 in compliance with 0.08 (3) MH303 3.50 EN 50022 standard 0.10 (4) MH304 3.90 (DIN 46277-3). 0.13 (5 in. MH305 4.70 0.15 (6) MH306 5.10 0.18 (7) MH307 5.70 0.20 (8) MH308 6.20 0.23 (9) MH309 6.90 0.25 (10) MH310 7.40 0.28 (11) MH311 8.10 Galvanized steel, 0.30 (12) MH312 8.60 prepunched 0.33 (13) MH313 9.20 0.36 (14) MH314 9.60 0.38 (15) MH315 10.20 0.41 (16) MH316 10.80 0.42 (17) MH317 11.60 0.46 (18) MH318 12.00 0.50 (19.68) MH320 13.10 1 (39.37) MH339 23.00 2 (78.74) MH379 32.70 High rise track Aluminum 1 (39.37) MH439 27.90 2 a Orders must specify the standard package quantity (Std. Pack) or multiples of that quantity. Length m (in.) Description Class 9080 Type Mounting Track 1 or 2 meter length Description .25 6 1.38 35 .98 25 Angle bracket kit 24 For mounting 9080GH or MH track to a panel at 45o angle. Includes 2 brackets and hardware for mounting the track to the brackets. 14.70 10 2 (78.74) AM1DE200 21.80 10 2 (78.74) AM1DP200 7.80 10 2 (78.74) DZ5MB201 23.20 10 1 (39.37) AB1PC15 7.50 10 DIN 1 Asymmetrical 32 mm track EN 50035 & NF C63-018 15 mm steel, zinc chromated DIN 2 Symmetrical 15 mm track EN 50045 Dimensions .04 1 .98 .98 .98 25 25 25 1.38 35 1.06 27 1.38 35 .49 12 .06 2 .59 15 .28 7 78.74 2000 .30 8 .59 15 AM1ED200 1.06 27 .98 .98 .98 25 25 25 .30 8 1.06 27 1.38 35 1.80 46 .49 12 1.17 30 78.74 2000 .04 1 .28 7 .30 8 AM1DP200 A 9080MH3** AM1ED200 7.5 mm depth, 1 mm steel, zinc chromated EN 50022 & NF C63-015 AM1DE200 .04 1 2 (78.74) 15 mm depth, 1.5 mm steel, zinc chromated Dimensions .98 25 Catalog Number DIN 3 15 mm depth, 1 mm steel, zinc chromated 78.74 2000 .71 18 $ Price Std. a ea. Pack Length m (in.) .04 1 9080MHA10 Catalog Number 9080MH82c .65 1.26 17 32 .59 .34 15 9 $ Price Std.a Pack ea. 7.20 .20 5 .24 6 .06 2 39.37 1000 78.74 2000 AB1PC15 DZ5MB201 .59 15 1 End Clamps Catalog Number $ Price ea. Std.a Pack End Clamps TERMINAL BLOCKS Plastic end clamp for 35 mm DIN 3 track, 8 mm (0.31 in.) wide AB1AB8P35 1.50 100 Metal end clamp for 35 mm DIN 3 track, 8 mm (0.31 in.) wide AB1AB8M35 2.40 100 Polycarbonate end clamp for 35 mm DIN 3 track, 8 mm (0.31 in.) wide 9080MHA10 2.40 50 b Not RoHS Compliant Plastic end clamp for 32 mm DIN 1 track, 7.5 mm (0.30 in.) wide AB1AB7P32 2.60 100 Metal end clamp for 32 mm DIN 1 track, 7.5 mm (0.30 in.) wide AB1AB10M32 2.60 100 Plastic end clamp for 15 mm DIN 2 track, 7.5 mm (0.30 in.) wide AB1AB715 1.50 100 Plastic end clamp for 35 mm DIN 3 track, 8 mm (0.31 in.) wide AB1AB8R35 1.50 100 RoHS Compliant 24-12 CP5 Discount Schedule © 2009 Schneider Electric All Rights Reserved Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com NEMA Style Terminal Blocks Type G Class 9080 / Refer to Catalog 9080CT9601 www.schneider-electric.us Selection Guide Maximum Maximum Voltage Currentb Description Solderless Box Lug for #22 to #8 AWG wire. 600 V Mounts on standard 9080GH track or 35 mm DIN 3 track. Fingersafe per DIN 57470. Similar to a 9080GR6 except with a 9080GH91 banana test plug adapter installed. Fingersafe per DIN 57470. 600 V 60 A 60 A Solderless Box Lug for #22 to #10 AWG wire. 600 V Can be mounted directly to a panel or can be mounted on 9080GH track. 40 A End Barriersc $ Price ea. Color Type Natural Black Blue Green Gray Orange Red Yellow Brown GR6 GRB6 GRL6 GRG6 GRE6 GRS6 GRR6 GRY6 GRN6 2.40 Natural GR6T 2.90 Natural Black Blue Green Gray Orange Red GK6 GKB6 GKL6 GKG6 GKE6 GKS6 GKR6 2.40 $ Price ea. Std. Packa Type 50 GM6B GMB6B GML6B GMG6B GME6B GMS6B GMR6B GMY6B GMN6B 0.78 50 GM6B 0.78 10 50 GK6B 0.93 Yellow GKY6 GM6 GMB6 GML6 GMG6 GME6 GMS6 GMR6 GMY6 GMN6 1.80 50 GM6B GMB6B GML6B GMG6B GME6B GMS6B GMR6B GMY6B GMN6B Std. Packa Blocks per ft 34 1 #8 1 #10 1–3 #12 1–4 #14 1–4 #16 1–5 #18 1–8 #20 1–10 #22 50 34 1–4 #16 1 #10 1–2 #12 1–2 #14 1–4 #16 1–5 #18 1–8 #20 1–10 #22 0.78 10 51 1 #10 1 #12 1 #14 1–2 #16 1–2 #18 1–5 #20 1–8 #22 1–2 #16 600 V 30 A 600 V 85 A Natural GC6 5.00 50 GC6B 1.30 10 28 1 #4 1 #6 1–2 #8 1–4 #10 1–5 #12 1–6 #14 1–6 #16 1–8 #18 600 V 170 A Natural GD6 10.10 10 GD6B 1.70 10 17 1 1/0 1 #1 1 #2 1–2 #4 1–3 #6 1–5 #8 1–6 #10 1–7 #12 600 V 255 A Natural GE6 27.00 10 Solderless Box Lug for #12 to #1/0 AWG wire. Mounts on standard 9080GH track or 35 mm DIN 3 track. Solderless Box Lug for #6 AWG to 250 kcmil wire. d Mounts on standard 9080GH track or 35 mm DIN 3 track. a b c d Copper Wire (stranded or solid) 10 Solderless Box Lug for #18 to #4 AWG wire. Mounts on standard 9080GH track or 35 mm DIN 3 track. Max. Wire Combinations Natural Black Blue Green Gray Orange Red Yellow Brown High Density Solderless Box Lug for #22 to #10 AWG wire. Mounts on standard 9080GH track or 35 mm DIN 3 track. Fingersafe per DIN 57470. Blocks None Required 10 1 250 kcmild 1 4/0 1 #1 1 3/0 1 #2 1 2/0 1 #4 1 1/0 1 #6 Orders must specify standard package quantity or multiples of that quantity. These maximum current values assume the use of insulated copper conductors with 75oC temperature rating, and are calculated based on NEC Article 310, Table 310-16. In most cases this value is the maximum ampacity of that wire or combination of wires (as listed in the above table) which has the greatest current carrying capacity. The actual allowable current for a particular application depends on the number, size, insulation class, and other characteristics of the wires used. The lower of the UL and CSA ratings are shown. One end-barrier is required for each assembly of like blocks. Terminals are tin plated, making them suitable for use with either copper or aluminum wire. File CCN E60616 XCFR2 File Class TERMINAL BLOCKS Table 24.18: 025490 3211 07 24 For Standard or Custom Assemblies . . . . . . . . . . . . . . . . . . . . . . page 24-15 For Mounting Track and Accessories . . . . . . . . . . . . . . . . . . . . . . page 24-16 For DIN 3 track and end clamps . . . . . . . . . . . . . . . . . . . . . . . . . . page 24-12 © 2009 Schneider Electric All Rights Reserved CP5 Discount Schedule 24-13 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com NEMA Style Terminal Block Type G Class 9080 / Refer to Catalog 9080CT9601 www.schneider-electric.us Selection Guide Description Self-Lifting Pressure Wire Connector for #18 to #12 AWG wire. Mounts on standard 9080GH track or 35 mm DIN 3 track. Flat Terminal Connector for #22 to #12 AWG wire. Screws are #6-32 x 5/16 in. for ring or spade lugs, 5/16 in. wide maximum. Mounts on standard 9080GH track or 35 mm DIN 3 track. Fingersafe per DIN 57470. Circuit Isolating Switchd with self-lifting pressure connectors for #18 to #10 AWG wire. Mounts on standard 9080GH track or 35 mm DIN 3 track. Slip-on Connectors for #22 to #12 AWG wire. Tabs accept 0.250 x 0.032 in. slip-on connectors Mounts on standard 9080GH track or 35 mm DIN 3 track. Transient Voltage Suppressorsf with box lug connectors for #18 to #10 AWG wire. Mounts on standard 9080GH track or 35 mm DIN 3 track. Fuse Block for 13/32 in. Dia. x 1-1⁄ 2 in. ferrule fuse with self-lifting pressure connectors. Fuse puller is included as standard. Fuses are not included. Mounts on standard 9080GH track or 35 mm DIN 3 track. Fingersafe per DIN 57470. Fuse Pullere Blown Fuse Indicator/ Pullers are neon pilot lights which plug on to the fuse in a standard Type GF6 fuse block. Maximum Voltage Maximum Currentb 600 V b 24 TERMINAL BLOCKS c d e 24-14 End Barriersc Type $ Price ea. 2.60 50 GP6B 1.00 10 32 1 or 2 1 or 2 1 or 2 1 or 2 GA6 1.80 50 GP6B 1.00 10 32 1 or 2 Conductors Per Screw #12–22 30 A GG6 18.00 10 GF6B 4.80 10 16 1 1 1 1–4 1–4 #10 #12 #14 #16 #18 600 V 20 A GS6 4.80 10 GF6B 4.80 10 16 1–2 1–2 1–2 1–2 1–2 1–2 #12 #14 #16 #18 #20 #22 120 V — GT6 20.70 5 GT6B 1.70 10 24 1 1 1 1–2 1–4 #10 #12 #14 #16 #18 600 V 30 A GF6 11.70 10 GF6B 4.80 10 16 1 1 1 1–4 1–4 #10 #12 #14 #16 #18 — — GH63 2.40 50 N/A 120–240 V — GLP3 11.90 10 N/A 277–600 V — GLP6 11.90 10 N/A $ Price ea. 40 A GP6 600 V 40 A 600 V Orders must specify the standard package quantity or multiples of that quantity. These maximum current values assume the use of insulated copper conductors with 75oC temperature rating, and are calculated based on NEC Article 310, Table 310-16. In most cases this value is the maximum ampacity of that wire or combination of wires (as listed in the above table) which has the greatest current carrying capacity. The actual allowable current for a particular application depends on the number, size, insulation class, and other characteristics of the wires used. The lower of the UL and CSA ratings are shown below. One end-barrier is required for each assembly of like sections. Not intended to make or break a live circuit. Power must be disconnected from the circuit before operation of the switch. Fuse puller is supplied as standard with Class 9080 Type GF6 fuse block. The 9080GH63 is a replacement fuse puller. CP5 Modules have RC circuitry for suppressing transient voltage, generated when opening a coil circuit, to approximately 200% of the peak line voltage, when used with 120 V coils. Type GT6 is suitable for use with Square D Class 8501 Type X, K, R and C relays or Square D Type S starters and contactors, Sizes 00-2. Std. Packa Max. Wire Combinations Blocks per ft Std. Packa Type f a Blocks Copper Wire (stranded or solid) #12 #14 #16 #18 N/A N/A N/A N/A 1200 900 VOLTS Table 24.19: 600 Without Transient Suppression With Built-in Transient Suppression 300 Terminal Blocks File CCN E60616 XCFR2 File Class 025490 3211 07 Blown Fuse Indicator Discount Schedule File CCN E63698 JDV5 File Class 025490 3211 07 0 TIME Table 24.20: To Order Specify • • Class Number Type Number How to Order Catalog Number Class 9080 Type GP6 For Standard or Custom Assemblies page 24-15 For Mounting Track and Accessories page 24-16 For DIN 3 track and end clamps page 24-12 © 2009 Schneider Electric All Rights Reserved Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com NEMA Style Terminal Blocks Type G Class 9080 / Refer to Catalog 9080CT9601 www.schneider-electric.us Standard Terminal Block Assemblies The assemblies listed in the table below consist of 6 ft (two 3 ft lengths packaged together) of terminal blocks. The terminal blocks are mounted on snap-off mounting track, which can be easily broken every 5/16 in. Every tenth terminal block is marked to aid in counting off the proper number of terminal blocks. After adding the proper end barrier and a slip-in end clamp to the blocks that were broken off, the custom assembly is ready for installation. Table 24.21: Standard Terminal Block Assemblies Description Assembly of 188 Type GA6 Assembly of 204 Type GR6 Assembly of 94 Type GF6 Assembly of 296 Type GM6 Assembly of 188 Type GP6 Type GA6188BC GR6204BC GF694BC GM6296BC GP6188BC $ Price 530.00 674.00 1311.00 830.00 653.00 Custom Terminal Block Assemblies Order an assembly built as required for the application. As standard, custom assemblies use 9080GH mounting track with screw on end clamps. Other options are available from the table below. One terminal block type: The number of blocks in the assembly is added to the end of the catalog number of the desired block. Example: an assembly of 25 9080GR6 blocks would be 9080GR625. More than one terminal block type in an assembly: A detailed drawing or sketch of the desired assembly must accompany the order. Table 24.22: Block Type GA6 GC6 GCB01–15 GCB20–150 GD6 GE6 GF6 GG6 Custom Assembly Pricing $ Price Per Block/ Terminal 2.80 6.10 68.00 84.00 12.20 31.80 14.00 14.60 Table 24.23: Custom Terminal Block Assemblies Option Suffix Example Substitute slip-in end clamps C 9080GR625C Substitute snap-off channel B 9080GR625BC a For direct mount assembly of 9080GK6 blocks D 9080GK67D Add a blank vinyl marking strip M 9080GR625M Add pre-marked (1–25 only) marking strip MPO 9080GR625MPO Mount on 35 mm DIN 3 track instead of T 9080GR625T 9080GH track a The 9080GH10 screw-on end clamp is not recommended for use with snap-off channel. It is recommended that the 9080GH11 slip-in end clamp be used. Therefore, when the suffix B is used, it should be followed by the suffix C. $ Price Per Block/ Terminal 3.30 2.70 2.90 3.50 3.30 3.80 3.80 0.05 0.24 Block Type GK6 channel mounted GK6 direct mounted GM6 GP6 GR6 GR6T GS6 Blank vinyl marking strip Pre-numbered (1-25 only) $ Price per block from Table 24.22 Number of blocks in the assembly x Subtotal (multiply # of blocks by price of blocks) Initial Charge for factory assemblies All except 9080GK6 direct mount ($7.00) OR for 9080GK6 direct mount ($3.60) Vinyl Marking Strips Adder for Suffix M—$0.05 per block OR adder for Suffix MPO—$0.24 per block Deduct for Suffix C—$2.40 Total everything from Subtotal down Apply the following rounding rules to the total obtained: $1.00 through $50.00 over $50.00 To Order Specify Class Number Type Number How to Order Catalog Number Class 9080 Type GA612 24 • • TERMINAL BLOCKS Table 24.24: Round to the nearest dime Round to the nearest dollar © 2009 Schneider Electric All Rights Reserved CP5 Discount Schedule 24-15 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com NEMA Style Terminal Blocks Type G Class 9080 / Refer to Catalog 9080CT9601 www.schneider-electric.us Table 24.25: 3/4 in. Mounting Track Table 24.27: $ Price Std. ea. Packa 3 GH103 2.40 5 4 GH104 2.40 5 5 GH105 2.60 5 6 GH106 2.60 5 7 GH107 2.60 5 8 GH108 3.00 5 9 GH109 3.00 5 10 GH110 3.30 5 11 GH111 3.30 5 Standard 12 GH112 3.50 5 Track 13 GH113 3.50 5 14 GH114 3.80 5 Snap-Off Standard 15 GH115 3.90 5 Track Track 16 GH116 4.20 5 17 GH117 4.40 5 18 GH118 4.80 5 36 GH136 11.70 5 48 GH148 15.20 5 72 GH172 22.70 5 36 GH236 11.70 20 Snap-Off High Rise 48 GH248 15.20 20 Track 72 GH272 22.70 20 High Rise 36 GH336 29.00 2 Note: For additional track and appropriate end clamps, see page 24-12. Style Table 24.26: Length (in.) Type Marking and Additional Accessories Description 25 ft blank vinyl marking GH220 strip Vinyl marking strip numbered 1-25 Accessories Description Type Type $ Price Std. Packa ea. 11.90 1 For GK6, GR6 GH21 4.40 5 For GA6, GP6 GH22 4.40 5 For GM6 GH230 4.40 5 Blank pin-feed marking tabs—6 x 20 (total 120) marking tabs GH200 for GD6, GR6, and GT6 blocks 1.70 20 Pre-marked 01 to 50 (2 sets) plus 20 Various marking tabs (total 120 marking tabs) GH210 for GD6, GR6, and GT6 blocks 13.10 5 Marking pen with permanent, fine line black ink GH40 8.00 12 Marking strip end plug for GK6, GR6, GM6, GA6, GP6, GC6, GD6, GE6, and GT6 blocks GH60 .39 50 Transition barrier between GK6 and all other G or K blocks GH61 .98 50 Cover for GR6 or GR6T GH62 blocks .98 50 $ Price Std. ea. Packa End Clamps Screw-on End Clamp (Not recommended for use on snap-off mounting track) GH10 2.40 50 Slip-in End Clamp (Not for use with 9080 GE6, GK6 blocks) GH11 .63 50 2-pole jumper for GM6 GH700 .59 20 6-pole jumper for GM6 GH710 1.20 10 2-pole jumper for GK6, GR6 GH72 .62 20 6-pole jumper for GK6, GR6 GH73 1.80 10 2-pole jumper for GC6 GH74 2.30 10 6-pole jumper for GC6 GH75 4.30 10 2-pole jumper for GD6 GH76 3.20 10 6-pole jumper for GD6 GH77 8.70 10 2-pole jumper for GA6, GP6 GH78 1.20 10 6-pole jumper for GA6, GP6 GH79 2.00 10 Snap-together fanning strip section for GA6 blocks 3.00 10 Jumpers Fanning Strip GH51 24 Snap-together fanning strip GH52 section for GK6, GR6 blocks TERMINAL BLOCKS a 3.30 Table 24.28: To Order Specify • • 24-16 CP5 Discount Schedule GH90 7.40 10 Test plug adapter for GR6T block (included as standard with GR6T) GH91 1.20 50 Angle bracket kit—for mounting 9080GH or MH track to panel at 45° angle. Includes 2 brackets and hardware for mounting the track to the brackets MH82 7.20 1 MHA10 2.40 50 Polycarbonate end clamp for 35 mm DIN 3 track, 8 mm (0.31 in.) wide 10 Orders must specify the standard package quantity or multiples of that quantity. Banana test plug for GR6T block Class Number Type Number How to Order Catalog Number Class 9080 Type GH10 © 2009 Schneider Electric All Rights Reserved Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Thermal-Magnetic Circuit Protectors Type GCB Class 9080 / Refer to Catalog 9080CT9901 www.schneider-electric.us Table 24.29: 9080GCB Thermal-Magnetic Circuit Protectorsb Internal Resistance Maximum Voltage Catalog Numbera $ Price ¾ 0.1 133 GCB01 0.5 6.6 GCB05 0.8 2.55 GCB08 66.00 1.0 1.97 GCB10 1.2 1.22 GCB12 1.5 0.86 GCB15 250 Vac 65 Vdc 2.0 0.49 GCB20 2.5 0.31 GCB25 3.0 0.20 GCB30 4.0 0.10 GCB40 72.00 5.0 0.08 GCB50 7.0 0.03 GCB70 10.0 <0.02 GCB100 125 Vac 65 Vdc 15.0 <0.02 GCB150 o These maximum current values assume the use of insulated copper conductors with 75 C temperature rating, and are calculated based on NEC Article 310, Table 310-16. In most cases this value is the maximum ampacity of that wire or combination of wires (as listed in the above table) which has the greatest current carrying capacity. The actual allowable current for a particular application depends on the number, size, insulation class, and other characteristics of the wires used. Discount schedule CP5. Maximum Current (A) GCB100 a b Selection Table 24.30: To properly select a Class 9080 Type GCB circuit protector, follow these steps: 1. 2. 3. 4. Determine the inrush correction factor from Table 24.30. Determine the temperature correction factor from Table 24.31. Determine the sealed current of the load that is being protected. Multiply the sealed current by the two correction factors and choose the closest circuit protector. File CCN E152841 QVNU2 File Class 025490 3211 07 1:7 1:8 Factor 1.6 1.7 1.3 Table 24.31: Ambient Temperature Note: Choosing a circuit protector with a value lower than the calculated value might cause nuisance tripping, while choosing the larger might provide a protector that will not properly protect the load. Factor Tripping Time: Tripping time of the circuit protector is determined from Table 24.32. Divide the circuit protector value by the temperature correction factor from Table 24.31 to determine actual rated current referenced in Table 24.32. 1.4 1.5 Table B—Ambient Temperature Correction Table 70oF o (21.1 C) 1.0 Table 24.32: Example: Solenoid with sealed current of 0.75 A, an inrush ratio of 1:6, and in an ambient temperature of 85oF: 0.75 x 1.5 x 1.05 = 1.18 Choose the 1.2 A protector Table A—Inrush Ratio Correction Table Note: For resistive loads, use inrush correction factor of 1.0. Inrush Ratio 1:1 to 1:4 1:5 1:6 100oF o (37.8 C) 1.1 120oF 140oF o (48.9 C) 1.2 o (60 C) 1.3 160oF o (71.1 C) 1.4 200oF 180oF o (82.2 C) 1.5 (93.3oC) 1.6 Table C—Tripping Times in Seconds at 70oF (21.1oC) Percent rated current 100% 200% 300% 400% 500% 600% 1000% 2000% and greater Tripping Time (s) no trip 10–40 38 1.5–9 0.8–6 0.003–4 0.003–2 Max. 0.02 Note: When several protectors are channel mounted adjacent to each other, the “no trip” current will be 80% of rated current at 70oF. Discount Schedule CP5 Thermal-Magnetic Circuit Protectors Type GB2 www.schneider-electric.us GB2 Thermal-Magnetic Circuit Protectorsc Maximum Voltage Description One pole Thermal Magnetic Circuit Protector Thermal Rating Catalog Number 0.5 A GB2CB05 1A GB2CB06 2A GB2CB07 $ Price ea.d Two pole Thermal Magnetic Circuit Protector Thermal Rating 0.5 A Catalog Number 1A GB2CD06 2A GB2CD07 GB2CD08 3A GB2CB08 3A GB2CB09 4A GB2CD09 5A GB2CB10 5A GB2CD10 43.60 $ Price ea.d GB2CD05 4A 300 Vac GB2CB06 Maximum Voltage Description 300 Vac 52.00 6A GB2CB12 6A GB2CD12 8A GB2CB14 8A GB2CD14 10 A GB2CB16 10 A GB2CD16 12 A GB2CB20 12 A GB2CD20 TERMINAL BLOCKS Table 24.33: c Discount schedule I. d Must order in multiples of 6 Note: For markers, use AB1( )R and AB1( )G markers from page 24-16 File Class 081630 3215 30 IEC 157-1 VDE 0660 File CCN E113720 QVNU2 24 GB2CD © 2009 Schneider Electric All Rights Reserved I Discount Schedule 24-17 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Power Distribution Blocks Type LB Class 9080 / Refer to Catalog 9080CT9603 www.schneider-electric.us These Power Distribution Blocks are listed to UL1953 and meet the feeder spacing requirements of UL508A. They carry a short circuit current rating (SCCR) according to the requirements of the 2005 National Electric Code (NEC and UL580A. For SCCRs, refer to the catalog, 9080CT9603R9/08. Table 24.34: Wire Range and Current Ratings Wire Range AWG/kcmil Catalog File E323110 LBFA368104 LBFA368101 LBFA368101S LBFA368106 LBFA369106 Line 2/0–14 2/0–14 2/0–14 2/0–14 400–6 LBFA369136 600–2 LBFA369112 600–2 CCN QPQS File 244651 Class 6228-01 Table 24.35: Main Branch (1) #14–2/0 (1) #6–350 kcmil (1) #4–600 kcmil (2) #4–350 kcmil (2) #6–500 kcmil (1) #14–2/0 (1) #14–2/0 (1) #6–400 kcmil (1) #6–400 kcmil (1) #6–400 kcmil (1) #4–500 kcmil (1) #4–500 kcmil (2) #14–2/0 (2) #6–500 kcmil (2) #6–500 kcmil Table 24.36: Two Pole Type d $ Price (1) #14–2/0 (1) #6–350 kcmil (1) #4–600 kcmil (2) #4–350 kcmil (2) #4–500 kcmil (4) #14–4 (6) #14–4 (4) #14–2 (6) #14–2 (8) #14–2 (6) #14–2/0 (12) #14–2 (6) #14–4 (8) #14–2/0 LBA162101 LBA163101 LBA164101 LBA165202 LBA1652021 LBA162104 N/A LBA163104 LBA163106 LBA164108 LBA165106 LBA165112 LBA163206 LBA165208 10.40 53.00 95.00 98.00 135.00 30.50 — 56.00 59.00 77.00 126.00 134.00 60.00 126.00 LBA262101 LBA263101 N/A LBA265202 LBA2652021 LBA262104 N/A LBA263104 LBA263106 LBA264108 LBA265106 LBA265112 LBA263206 LBA265208 22.10 81.00 — 147.00 206.00 45.80 — 84.00 89.00 116.00 189.00 201.00 90.00 LBA362101 LBA363101 LBA364101 LBA365202 LBA3652021 LBA362104 LBA362106 LBA363104 LBA363106 LBA364108 LBA365106 LBA365112 LBA363206 25.70 107.00 183.00 189.00 243.00 68.00 131.00 113.00 122.00 161.00 233.00 261.00 122.00 (12) #14–4 LBA165212 135.00 LBA265212 189.00 206.00 LBA365208 LBA365212 251.00 261.00 Type d $ Price Type d N/A LBA261104 — 30.60 LBA361101 LBA361104 $ Price Type d Aluminumb One Pole (1) #14–2 (4) #18–10 Type d Two Pole $ Price LBA161101 LBA161104 13.40 26.40 TERMINAL BLOCKS g h LB53 $ Price 23.40 58.00 Copperc One Pole Branch Type d Two Pole $ Price Type d (1) #18–1/0 (1) #18–1/0 LBC162101 99.00 N/A (1) #6–250 kcmil (1) #6–250 kcmil LBC163101 125.00 N/A (1) #14–2/0 (4) #14–4 LBC162104 99.00 LBC262104 (1) #4–500 kcmil (6) #14–2 LBC163106 153.00 LBC263106 (2) #14–2/0 (6) #14–4 LBC163206 134.00 LBC263206 (2) #4–500 kcmil (8) #14–2/0 LBC165208 297.00 N/A (2) #6–500 kcmil (12) #14–2 LBC165212 284.00 N/A a Lugs suitable for use with 75oC conductors. (#) indicates number of conductors. b Aluminum blocks will accept either Al or Cu conductors. c Cu blocks will accept copper conductors only. 19.20 Three Pole Copper Power Distribution Blocks 24 LBA365…, LBC365 Three Pole $ Price (1) #14–2 (1) #14–2 Clear Plastic Covers 270.00 Type d Branch Note: There are no covers for miniature blocks. For LBA Type Type $ Price ea. g LBA162…, LBC162 LB21 11.30 LBA262…, LBC262 LB22 13.50 LBA362…, LBC362 h LB23 15.80 LBA163…, LBC163 LB31 12.50 LBA263…, LBC263 LB32 14.70 LBA363.… LBC363 LB33 17.00 LBA164… LB41 13.50 LBA264… LB42 15.80 LBA364… LB43 18.00 LBA165…, LBC165 LB51 14.70 LBA265…, LBC265 LB52 17.00 263.00 335 Miniature Power Distribution Blocks Main Table 24.38: 335 335 $ Price Lug Wire Rangea LBC165212 335 98.00 83.00 90.00 105.00 180.00 Type d Main Table 24.37: AL 135 135 135 135 270 Aluminumb One Pole Lug Wire Rangea LBA161104 $ Price CU 175 175 175 175 335 Standard Power Distribution Blocks Lug Wire Rangea LBA365212 Current Amps Load (4) 4 -14 2/0 -14 1/4 - 20 stud (6) 4 -14 (6) 2 -14 (3) 1/0 -14 (6) 2 -14 (12) 4 -14 (0.045 in. thick) Dim. A 1.062 1.875 2.688 1.782 3.313 4.844 2.125 4.000 5.875 2.719 5.656 Dim. B 2.750 2.750 2.750 3.813 3.813 3.813 4.563 4.563 4.563 5.313 5.313 8.375 5.313 Three Pole $ Price — LBC362101 201.00 — LBC363101 233.00 147.00 LBC362104 248.00 228.00 LBC363106 354.00 201.00 LBC363206 269.00 — LBC365208 593.00 — LBC365212 567.00 d CE Marked. e Refer to catalog for dimensions. f UL component recognized (File E60616 CCN XCFR2). CSA certified (File LR70361, Class 070361). Application Data Voltage Rating—Class B & C—600 V Blocks are rated based on NEC Table 310-16 using 75oC wire. Aluminum blocks are tin plated high conductive aluminum. Copper blocks are tin plated high conductive copper. Housing material: • • Miniature Blocks are made from high impact thermoplastic rated at 125oC. max. & -40oC. min. Full Size Blocks are made from general purpose phenolic rated at 150oC. max. & -40oC. min. All blocks have a flammability rating of UL 94V-0. Most blocks have a short circuit current rating for UL508A up to 200 kA for branch circuit applications. For the actual ratings, see catalog 9080CT9603R9/08. RoHS Compliant These covers must be ordered in multiples of 5. Each cover comes with two self-tapping screws. Will not work on a 9080LBA362106 block. 24-18 CP1 Discount Schedule © 2009 Schneider Electric All Rights Reserved Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Fuseholders Type FB Class 9080 / Refer to Catalog 9080CT9603 www.schneider-electric.us Rating (A) f 30a 60a 100b No. of Poles 1 2 3 1 2 3 1 2 3 Table 24.40: Rating (A) f 30b 60b 100b No. of Poles 250 V—Classes H and R Class H Type FB1211 FB2211 FB3211 FB1221 FB2221 FB3221 Class Rd $ Price 12.90 21.90 31.10 21.90 39.20 55.00 Type $ Price FB1211R 19.20 FB2211R 28.40 FB3211R 37.20 FB1221R 28.40 FB2221R 45.80 FB3221R 61.00 FB1231Re 59.00 — FB2231Re 98.00 FB3231Re 138.00 — Class H Class Rd 1 2 3 1 2 3 $ Price 24.30 42.60 54.00 31.10 51.00 54.00 FB3621R 78.00 3 FB3631 147.00 FB3631R 158.00 Rating (A) f No. of Poles 30a 1 2 3 #14–10 Cu #14–2 Cu or Al #6–2/0 Cu or Al FB2221 Type $ Price FB1611R 30.60 FB2611R 48.50 FB3611R 60.00 FB1621Re 37.20 Lug Wire Range #14–10 Cu #6–2/0 Cu or Al Type M Class CCd 600 V—Class H Only (Copper Only) Rating (A) f #14–2 Cu or Al 600 V Series—Miniature Fuse Dimension (13/32 x 1-1/2 in.) Type $ Price Type $ Price FB1611M 13.50 FB1611CC 13.50 FB2611M 19.80 FB2611CC 22.10 FB3611M 24.30 FB3611CC 24.80 Table 24.42: 30b 1 2 3 Type FB1611 FB2611 FB3611 100b 3 FB3631C Table 24.43: 60b b c Base is high impact thermoplastic— maximum operating temperature 125oC Base is general purpose phenolic— maximum operating temperature 150oC Base is high impact polyester— maximum operating temperature 130oC • Table 24.45: • • #14–10 Cu #6–2/0 Cu Lug Wire Range #2–14 AWG Cu—Al #2–14 Cu—Al $ Price Std. ea. Pack h 4.10 100 Fuse Sizes—(Diameter x Length) Class of Fuse A All 30 A blocks have pressure wire connectors. All 60, 100 and 200 A blocks have box lug connectors. 30 60 100 200 Approvals: • Type 35 mm DIN 3 Track Adapter For 9080 FB*211, FBDIN3 FB*211R, e FB*611M, and FB*611CC Fuseholders Lug termination: • • $ Price 26.00 45.50 63.00 32.00 54.00 75.00 Description All 30 and 60 A fuse clips are copper alloy tin plated. All 100 and 200 A fuse clips are one piece aluminum with copper spring tin plated. All Class H, R and J fuses are standard with reinforced fuse clips. Lug Wire Range Track Adapter Clip material: • • Type FB1611J FB2611J FB3611J FB1621Je FB2621Je FB3621Je 1 2 3 1 2 3 Table 24.44: Base material: 158.00 Class J No. of Poles 30bg #14–10 Cu $ Price 24.30 42.60 54.00 600 V—Class J Rating (A) f Lug Wire Range Class H No. of Poles Application Information: a FB3221R 600 V—Classes H and R Type FB1611 FB2611 FB3611 FB1621 FB2621 FB3621 Table 24.41: Lug Wire Range The Type M fuseholders are UL component recognized (File E40747 CCN IZLT2). The Type H, R, J and CC are UL Listed (File E40747 CCN IZLT). All fuseholders are CSA certified (File 70360 Class 6225-01). Flammability rating of all FB fuse blocks is UL 94V-0. RoHS Compliant Class H/R— Class H/R— Class M/CC— Class J—600 V 300 V 600 V 600 V 9/16 x 2 in. 13/16 x 5 in. 13/32 x 1-1/2 in. 13/16 x 2-1/4 in. 13/16 x 3 in. 1-1/16 x 5-1/2 in. N/A 1-1/16 x 2-3/8 in. 1 x 7-7/8 in. N/A N/A 1 x 7-7/8 in. 1-1/2 x 7-1/8 in. 1-3/4 x 9-5/8 in. N/A N/A d Class R and CC fuseholders accept current limiting Class R & CC fuses only. e Not in stock. Order point—Raleigh, NC. f Specified wire ranges are based on 75oC wire. Wires with temperature ratings other than 75oC are approved while observing NEC Article 310 wire tables for allowable ampacities of insulated conductors. Class R, J and CC fuse blocks are tested and approved for 200,000 AIC in accordance with UL 512. g Can be mounted directly to a panel or on 35 mm DIN 3 track. h Orders must specify the standard package quantity or multiples of that quantity. Sold in standard pack quanties. Table 24.46: To Order Specify Class Number Type Number Catalog Number Class 9080 Type FB1211 24 • • How to Order TERMINAL BLOCKS Table 24.39: © 2009 Schneider Electric All Rights Reserved CP1 Discount Schedule 24-19 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Cable Ends DZ5 and AZ5 Refer to Catalog 9080CT9701 www.schneider-electric.us Conform to NF C 63-023 Standard Mark and terminate wires simultaneously Table 24.47: Without Marking Flag Wire Size AWG mm2 Sleeve color 26 0.25 Yellow 24 DZ5CE005 0.34 Green 22 0.50 White 20 0.75 Blue B 18 D C A 1.00 16 1.50 Yellow 14 2.50 Gray 4.00 C D 22 A 6.00 Table 24.48: B Orange Green 0.25 Yellow 24 0.34 Green 22 0.50 White 20 0.75 Blue 18 1.00 Red 16 1.50 Black 14 2.50 Gray B D C 12 4.00 Orange 10 6.00 Green 8 10.00 Brown 6 16.00 White 4 25.00 Black 2 35.00 Red D A 0 50.00 Table 24.50: 11 6.2 13 8.2 11 6.2 13 8.2 DZ5CE003 11 6.2 DZ5CE005L6b 13 8.2 16.8 12 11 6.2 13 8.2 11.5 6.2 13.5 8.2 24 TERMINAL BLOCKS E B C D a b c d e D 1.2 2.2 1.4 3 1.6 3.1 DZ5CE002 DZ5CE003L6 DZ5CE005b DZ5CE005L12 DZ5CE007b DZ5CE010L6b 1.8 3.4 12 DZ5CE010L12 DZ5CE015L6b 8.2 17.7 14.5 8.2 14.5 8.2 24 17.7 17.3 9.8 25.5 17.5 20 11.5 26 17.5 2.1 4 DZ5CE015b DZ5CE0153b 2.35 4.2 2.7 4.6 3.3 5.5 0.16 0.18 0.26 0.18 1000 DZ5CE010b 6.2 22.8 Std. Pack d DZ5CE007L6b 11.5 13.5 $ Price ea. DZ5CE002L6 16.8 13 8.2 13.5 14.5 DZ5CE020 DZ5CE025b 0.28 0.22 0.42 0.24 DZ5CE0253b 0.44 DZ5CE042b 0.42 DZ5CE043b 0.62 DZ5CE062 0.48 DZ5CE063 0.66 3.95 7 1.2 2.2 1.4 3 DZ5CA005b 1.6 3.1 DZ5CA007b 1.8 3.4 DZ5CA010b 2.1 4 DZ5CA015b 2.7 4.6 DZ5CA025b DZ5CA002 DZ5CA003 100 0.26 1000 0.32 Blue 19.5 11.5 3.3 5.5 DZ5CA042b 0.38 25.5 17.5 3.3 5.5 DZ5CA043b 0.46 20 11.5 3.95 7 DZ5CA062 0.62 26 17.5 3.95 7 DZ5CA063 0.64 21.5 12 4.95 8.4 DZ5CA102 0.72 27 17.5 4.95 8.4 DZ5CA103 0.78 23.5 12 6.35 9.8 DZ5CA162 0.86 29 17.5 6.35 9.8 DZ5CA163 0.96 30 17.5 8.15 12 DZ5CA253 1.10 30 16 9 13.5 DZ5CA352 1.30 39 25 9 13.5 DZ5CA353 1.50 36 20 11 15.7 DZ5CA502 1.50 41 25 11 15.7 DZ5CA503 1.70 1000 100 20 Dual Wire Cable Ends A AZ5DE010 C Catalog Number ac B Marking Flag Optional e 2 4.5 Dimensions (mm) A With Marking Flag 26 Table 24.49: DZ5CA042 Black 2.00 10 DZ5CA007 Red 14 12 Strip the wire, insert it into the cable end and crimp it. Up to 7 markers can be used. 22 0.50 White 20 0.75 Blue 18 1.00 Red 16 1.50 Black B 13 8 13.5 C D E 1.4 2.5 4.7 AZ5DE005 1.6 2.8 5.0 AZ5DE007 1.8 3.4 5.4 AZ5DE010 2.1 3.6 6.6 AZ5DE015 0.24 500 0.26 14 2.50 Gray 24 10 2.7 4.2 7.8 AZ5DE025 0.32 250 Bold faced catalog numbers are stocked in the United States. These catalog numbers are UL Component Recognized (File E164872 CCN ZMMT2) provided the AT1PA crimping tool is used to crimp the cable end. CE Marked. Order must specify the standard pack quantities or multiples of that quantity. Will accept an AR1SC03 cable marker from page 24-22. A RoHS Compliant 24-20 I Discount Schedule © 2009 Schneider Electric All Rights Reserved Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Cable Ends AR1 and AT1 Refer to Catalog 9080CT9701 www.schneider-electric.us Table 24.51: Cable End Markers & Accessories Catalog Number Style AR1SC01 AR1SC02 AR1SC03 Adjustable collar type marker holder for #14 to #2 wire Clip-on marker holder for #18 to #16 wire (7 markers max.) Cable end marker tags for DZ5CA042 to DZ5CA253 Card of 200 yellow markers with black numeral 0 thru 9 Card of 200 yellow markers with black letters A thru Z Card of 200 black markers with a white 0 marked on them Card of 200 brown markers with a white 1 marked on them Card of 200 red markers with a black 2 marked on them Card of 200 orange markers with a black 3 marked on them Card of 200 yellow markers with a black 4 marked on them Card of 200 green markers with a black 5 marked on them Card of 200 blue markers with a black 6 marked on them Card of 200 violet markers with a black 7 marked on them Card of 200 gray markers with a black 8 marked on them Card of 200 white markers with a black 9 marked on them Card of 200 blank yellow markers Card of 200 blank green markers Card of 200 yellow markers with a black + marked on them Card of 200 yellow markers with a black—marked on them Complete set of numeral markers 0 thru 9, plus one card each of the “+” “-”, yellow blanks, and green blanks/one AT1PA1 positioning tool. Each kit has 200 of each item. Complete set of letter markers A thru Z, plus one card each of the “+” “-”, yellow blanks, and green blanks/one AT1PA1 positioning tool. Each kit has 200 of each item. Table 24.52: AR1SC01 AR1SC02 AR1SC03 AR1MA01b AR1MB01b AR1MC010 AR1MC011 AR1MC012 AR1MC013 AR1MC014 AR1MC015 AR1MC016 AR1MC017 AR1MC018 AR1MC019 AR1MA0196 AR1MA0197 AR1MA0198 AR1MA0199 $ Price Std. ea. Packa 0.42 0.42 100 0.12 136.00 300.00 13.60 13.60 13.60 13.60 13.60 13.60 13.60 13.60 1 13.60 13.60 12.20 12.20 12.20 12.20 AR1MA01 136.00 AR1MB01 300.00 Cable End Tools Catalog Number AT1PA1 Description Cable end marker positioning tool Automatic stripping and cutting tool for 0.8 mm to 4 mm cable, AT1PA7 adjustable stripping length 2 2 Crimping tool for cable ends 0.5 mm to 16 mm AT1PA2 AT1PA4 Crimping tool for cable ends 10 mm2 to 35 mm2 Organizing case for cable ends—holds AT1HB2 stripping tool and cable ends (not supplied) a Order must specify the standard pack quantities or multiples of that quantity. b Complete the catalog number by adding the number or letter desired. Examples: AR1 MA015 is a card of 200 yellow markers with a black 5 marked on them. R1 MB01T is a card of 200 yellow markers with a black T marked on them. AT1PA1 $ Price 30.20 506.00 246.00 268.00 116.00 AT1PA7 AR1MA019 AT1PA2 AT1HB2 24 TERMINAL BLOCKS AT1PA4 © 2009 Schneider Electric All Rights Reserved I Discount Schedule 24-21 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Advantys TELEFAST® 2 Prewired Connection System Refer to Catalog 8501CT9801 www.schneider-electric.us The TELEFAST 2 system is a set of products for the rapid connection of I/O modules (24 Vdc discrete, analog and counters) to Various control circuit components. These components act as a substitute for screw terminal blocks, remotely locating and partly eliminating the single wire connections. The system connects only to channels with HE10 and SUB-D connectors, or to standard terminal blocks with a cabled connector. Variations within the listing of modules include those with and without relays (electromechanical and solid state), analog and counter modules, and special function modules. Pre-wired cables available allow you to connect directly to: • Schneider Electric (Modicon® family) — TSX Premium™ — TSX Micro — TSX Series 7 — Twido — Quantum™ — Compact — April S5000/7000 — NUM1020/1060 • Siemens — S7 – 200/300/400 — S5 – 95U to 155U • Allen-Bradley — SLC500 Advantys TELEFAST 2 Product Features Blade Isolation Switch on the 0 V terminal of the Power Supply Fuse Protection for the Cable and Power Supply Test Point for 2.3 mm Plug LEDs Indicating I/O State and Blown Fuse Power Supply LED Fusing per Channel Blade Isolation Switches per Channel 35 mm DIN-rail Mounting Detachable Terminal Blocks (Screw Terminations) In addition, other accessories include: • • • • • • • • I/O simulators Continuity blocks Label marking software Splitter bases (16, 23, and 32 channels) Mounting kits Detachable terminal strips Wiring pass-through connectors Fuses Custom Labeling of Channels (cover face) and Wiring Diagram (under cover) NOTE: Not all features available on all modules. 24 TERMINAL BLOCKS 24-22 © 2009 Schneider Electric All Rights Reserved Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.6 Linearized : Yes Create Date : 2009:03:04 15:07:16-06:00 Modify Date : 2009:07:21 12:32:07-07:00 Has XFA : No XMP Toolkit : Adobe XMP Core 4.2.1-c043 52.372728, 2009/01/18-15:56:37 Instance ID : uuid:a6062a9c-7038-5348-8e93-d66df37d712a Document ID : adobe:docid:indd:b9f34800-0a58-11de-94b9-c9f90b55436d Rendition Class : proof:pdf Derived From Instance ID : d77ef6d0-0342-11de-8b2d-ac93865527c8 Derived From Document ID : adobe:docid:indd:59304f5e-032f-11de-8b2d-ac93865527c8 Manifest Link Form : ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream Manifest Placed X Resolution : 300.00, 300.00, 72.00, 72.00 Manifest Placed Y Resolution : 300.00, 300.00, 72.00, 72.00 Manifest Placed Resolution Unit : Inches, Inches, Inches, Inches Manifest Reference Instance ID : uuid:96E6D313E0F8DD1193D3A206EA549064, uuid:5B665946E0F8DD1193D3A206EA549064, uuid:4FF6EF6A225911DD91B6E1D8435B5599, uuid:4FF6EF6A225911DD91B6E1D8435B5599 Manifest Reference Document ID : uuid:96CC0F152BCCDD11A7E9FDD05B4D97A8, uuid:4480D645750C11DDA036ECEE5BB6739C, uuid:4FF6EF69225911DD91B6E1D8435B5599, uuid:4FF6EF69225911DD91B6E1D8435B5599 Metadata Date : 2009:07:21 12:32:07-07:00 Creator Tool : Adobe InDesign CS3 (5.0) Thumbnail Format : JPEG Thumbnail Width : 256 Thumbnail Height : 256 Thumbnail Image : (Binary data 10674 bytes, use -b option to extract) Format : application/pdf Title : Schneider Electric DIGEST 175 - Terminal Blocks Creator : Producer : Adobe PDF Library 8.0 Trapped : False Page Layout : SinglePage Page Mode : UseOutlines Page Count : 22EXIF Metadata provided by EXIF.tools