Safety Network Controller

NE1A-SCPU Series
CSM_NE1A-SCPU_Series_DS_E_6_3

Achieve Safety Control through
Programming.
• Compact Safety Controller.
• The NE1A-SCPU01-V1 provides 16 built-in safety inputs
and 8 built-in safety outputs.
The NE1A-SCPU02 provides 40 built-in safety inputs and
8 built-in safety outputs.
• Reduced wiring with safety networks. Connect up to 32
Safety Terminals.
• Monitor the safety system from Standard Controllers
across the network.
• ISO13849-1 (PLe) and IEC 61508 SIL3 certification.

Ordering Information
List of Models
No. of I/O points

Name

Safety inputs

Safety Network Controllers

Test outputs

Model

Safety outputs

Unit version

16

4

8

NE1A-SCPU01-V1 2.0

40

8

8

NE1A-SCPU02

2.0

Note: The standard NE1A Controllers are equipped with spring-cage terminal blocks, but other screw terminal blocks are available if desired, e.g.,
to replace previous terminals. Refer to CIP Safety on DeviceNet Accessories.

Specifications
Certified Standards
Certification body

TÜV Rheinland

UL

Specifications
Standard

NFPA 79-2012
EN ISO13849-1: 2008
IEC61508 part 1-7: 2010
IEC61131-2: 2007
EN ISO13849-2: 2012
EN61000-6-4: 2007
EN61000-6-2: 2005
EN60204-1: 2006
EN ISO13850: 2006(EN418: 1992)
ANSI RIA15.06-1999
ANSI B11.19-2010
UL508
ANSI/ISA 12.12.01
UL1998
NFPA79
IEC61508
CSA22.2 No.142
CSA22.2 No.213

Item

Model

Communications power supply voltage
Internal circuit power supply
voltage (V0) *1
I/O power supply voltage (V1,
V2) *1

Current
consumption

NE1A-SCPU01-V1

NE1A-SCPU02

11 to 25 VDC supplied via communications
connector
20.4 to 26.4 VDC (24 VDC −15%/+10%)

Communications
power supply

24 VDC, 15 mA

Internal circuit
power supply

24 VDC, 230 mA

I/O power supply
*2

24 VDC, 40 mA (Input) 24 VDC, 80 mA (Input)
120 mA (Output)
150 mA (Output)

24 VDC, 280 mA

Overvoltage category

II

Noise immunity

Conforms to IEC61131-2.

Vibration resistance

10 to 57 Hz: 0.35 mm, 57 to 150 Hz: 50 m/s2

Shock resistance

150 m/s2: 11 ms

Mounting method

DIN Track (IEC 60715 TH35-7.5/TH35-15)

Ambient operating temperature

−10 to 55°C

Ambient operating humidity

10% to 95% (with no condensation)

Ambient storage temperature −40 to 70°C
Degree of protection

IP20

Serial interface

USB version 1.1

Weight

460 g max.

690 g max.

*1. V0-G0: Internal control circuit
V1-G1 (G): For external input device, test output
V2-G2 (G): For external output device
The two ground terminals on the NE1A-SCPU02 are internally
connected.
*2. Not including power consumption for external devices.

1

NE1A-SCPU Series
Safety Input Specifications

Test Output Specifications

Input type

Sinking inputs (PNP)

Output type

Sourcing outputs (PNP)

ON voltage

11 VDC min. between each terminal and
ground

Rated output
current

0.7 A max./output *

OFF voltage

5 VDC min. between each terminal and
ground

ON residual
voltage

1.2 V max. between each output terminal and
V1

OFF current

1 mA max.

Leakage current

0.1 mA max.

Input current

4.5 mA

*The maximum current for simultaneously ON outputs is 1.4 A.
(T0 to T3: NE1A-SCPU01-V1, T0 to T7: NE1A-SCPU02)
A 15 to 400-mA, 24-VDC external indicator can be connected to T3
and T7.

Safety Output Specifications
Output type

Sourcing outputs (PNP)

Rated output
current

0.5 A max./output

ON residual
voltage

1.2 V max. between each output terminal and
V2

Leakage current

0.1 mA max.

DeviceNet Communications Specifications
Communications protocol

DeviceNet compliant

Connection form

Multi-drop system and T-branch system can be combined (for trunk line and branch lines)

Communications speed

500/250/125 kbps

Communications media

Special cable, 5 conductors (2 for communications, 2 for power supply, 1 for shielding)

Communications distance

Communications speed

Max. network length

500 kbps

100 m max. (100 m max.)

250 kbps

250 m max. (100 m max.)

125 kbps

500 m max. (100 m max.)

Branch length

Total branch length
39 m max.

6 m max.

78 m max.
156 m max.

Note: Figures in parentheses ( ) indicate values when a thin cable is used.
Communications power supply 11 to 25 VDC
No. of connectable nodes

63

Safety I/O communications
(Pre-Ver. 1.0)

Safety Master function
• Max. no. of connections: 16
• Max. data size: Input 16 bytes or output 16 bytes (per connection)
• Connection type: Single-cast, multi-cast
Safety Slave function
• Max. no. of connections: 4
• Max. data size: Input 16 bytes or output 16 bytes (per connection)
• Connection type: Single-cast, multi-cast

Safety I/O communications
(unit version 1.0 or later)

Safety Master function
• Max. no. of connections: 32
• Max. data size: Input 16 bytes or output 16 bytes (per connection)
• Connection type: Single-cast, multi-cast
Safety Slave function
• Max. no. of connections: 4
• Max. data size: Input 16 bytes or output 16 bytes (per connection)
• Connection type: Single-cast, multi-cast

Standard I/O communications
(all unit versions)

Standard Slave function
• Max. no. of connections: 2
• Max. data size: Input 16 bytes or output 16 bytes (per connection)
• Connection type: Poll, bit-strobe, COS, cyclic

Message communications

Max. message length: 552 bytes

2

NE1A-SCPU Series

Functions
Function Blocks
NE1A-SCPU-series Controller support the following logic functions and function blocks. Support depends on the unit version.

Logic Functions
Name

Function Blocks
Function list entry

Supporting unit
versions

Name

Function list entry

NOT

NOT

Reset

Reset

AND

AND

Restart

Restart

OR

OR
EXOR

Emergency Stop
Monitoring

E-STOP

Exclusive OR

All

Exclusive NOR

EXNOR

Light Curtain Monitoring

RS Flip-flop

RS-FF

Light Curtain
Monitoring

Comparator

Comparator

Safety Gate Monitoring

Safety Gate
Monitoring

Two-hand Controller

Two Hand Controller

1.0 or later

Off-Delay Timer

Off-Delay Timer

On-Delay Timer

On-Delay Timer

User Mode Switch
Monitoring

User Mode Switch

External Device
Monitoring

EDM

Routing

Routing

Muting

Muting

Enable Switch
Monitoring

Enable Switch

Pulse Generator

Pulse Generator

Counter

Counter

Multiconnector

Multi Connector

Supporting unit
versions

All

1.0 or later

3

NE1A-SCPU Series

Internal Circuit Diagrams
NE1A-SCPU01-V1
NC

Terminal name

NC

V0
24 VDC

G0

Safety Input Circuit
Test Output Circuit

USB

24 VDC

G1
T0
T3

Description

V0

Power supply terminal for internal circuit
The two V0 terminals are internally connected.

G0

Power supply terminal for internal circuit
The two G0 terminals are internally connected.

V1

Power supply terminal for external input device
and test output

G1

Power supply terminal for external input device
and test output

V2

Power supply terminal for external output device

IN0

G2

Power supply terminal for external output device

IN15

IN0 to IN15

Safety input terminal

T0 to T3

Test output terminal
Connected to IN0 to IN15 safety inputs.
Each test output terminal outputs a different test
pulse pattern.
Terminal T3 also supports a current monitoring
function for the output signal.
Example: Muting lamp

V2
Safety Output Circuit

D+
D−

G0

V1

Internal Circuit

DC-DC Converter
(Non-insulated)

V+
CAN H
Shield
CAN L
V−

DeviceNet
Physical Layer

DC-DC Converter
(Insulated)

V0

24 VDC

G2

OUT0
OUT7

L

OUT0 to OUT7 Safety output terminals

L

USB

24 VDC

G0

Safety Input Circuit
Test Output Circuit

24 VDC

G

T7
IN0

V0
G0

Power supply terminal for internal circuit
The two G0 terminals are internally connected.

V1

Power supply terminal for external input device
and test output

G

Power supply terminal for external input device
and test output

V2

Power supply terminal for external output device

G

Power supply terminal for external output device

IN0 to IN39

Safety input terminal

T0 to T3

Test output terminal
Connected to IN0 to IN19 safety inputs.
Each test output terminal outputs a different test
pulse pattern.
Terminal T3 also supports a current monitoring
function for the output signal.
Example: Muting lamp

T4 to T7

Test output terminal
Connected to IN20 to IN39 safety inputs.
Each test output terminal outputs a different test
pulse pattern.
Terminal T7 also supports a current monitoring
function for the output signal.
Example: Muting lamp

V2
24 VDC

G

OUT0
OUT7

Description
Power supply terminal for internal circuit
The two V0 terminals are internally connected.

T0

IN39

Safety Output Circuit

D+
D−

Terminal name
V0

V1

Internal Circuit

DC-DC Converter
(Non-insulated)

V+
CAN H
Shield
CAN L
V−

DeviceNet
Physical Layer

DC-DC Converter
(Insulated)

NE1A-SCPU02

L
L

OUT0 to OUT7 Safety output terminals

Refer to the CIP Safety on DeviceNet Safety Network Controllers
Operation Manual (Cat. No. Z906) for wiring examples.

4

NE1A-SCPU Series

Dimensions

(Unit: mm)

NE1A-SCPU01-V1
MS
NS
LOCK
COMM

NE1A-SCPU01-V1
SAFETY NETWORK CONTROLLER
USB
NODE ADR
0

1
2
3
4

2

4

6

8

1

3

5

7

9

10 12 14
11 13 15

IN

0

×10

0

×1

O
N

ON
BAUD RATE

0

2

4

6

1

3

5

7

V1 G1 T0 T2

8

10 12 14

9

11 13 15

0

2

4

6

1

3

5

7

V1 G2 T1 T3
24VDC

(99) 111.1

OUT

V1 G1 T0 T2

0

2

4

6

V1 G2 T1 T3

1

3

5

7

24VDC
V0 G0 V0 G0

90.4

(114.1)
131.4

NE1A-SCPU02
MS
NS
LOCK
COMM

NE1A-SCPU02
SAFETY NETWORK CONTROLLER
USB
NODE ADR
0

1
2
3
4

2

4

6

8

10 12 14

20 22 24 26

28 30 32 34

1

3

5

7

9

11 13 15

21 23 25 27

29 31 33 35

IN

0

×10

0

×1

O
N

0

2

1

3

ON
BAUD RATE

24VDC

4

6

8

10 12 14

20

22

5

7

9

11 13 15

21

23

24

26

28

30

29

31

32

34

33

35

4

6

25

27

16 18

0

2

36

38

17 19

1

3

37

39

5

7

IN

OUT

(99) 111.1

OUT

IN

V1 G

16 18

T0 T2

0

2

NC NC 36 38

T4

T6

4

6

V2 G

17 19

T1

T3

1

3

NC NC 37 39

T5

T7

5

7

24VDC
V0 G0 V0 G0

135.6

(114.1)
131.4

5

NE1A-SCPU Series

Safety Precautions
Refer to the "Safety Precautions for All CIP Safety on DeviceNet Systems" for precautions.
Be sure to read the following user's manual for other details required for correct use of the Safety Network
Controller.
CIP Safety on DeviceNet Safety Network Controller User's Manual (Cat. No. Z916)

Functions Supported According to Unit Version
Model

❍:

Supported, ---: Not supported

NE1ASCPU01

NE1ASCPU01-V1

NE1ASCPU02

Pre-Ver. 1.0

Unit version
1.0/2.0

Unit version
1.0/2.0

128

254

254

---

❍

❍

Selecting a rising edge as the reset condition for
Reset and Restart function blocks

---

❍

❍

Using local I/O status in logic programming

-----

❍

❍

Unit version
Function
Logic processing functions
Maximum program size (total number of function
blocks)
New Function Blocks

• RS flip-flop
• Multiconnector
• Muting
• Enable Switch Monitoring
• Pulse Generator
• Counter
• Comparator

❍

❍

❍
(Unit version 2.0 or higher)

❍
(Unit version 2.0 or higher)

-----

❍

❍

❍

❍

Number of safety I/O connections for Safety Master

16

32

32

Selecting operating mode for safety I/O
communications when communications errors
occur

---

❍

❍

Attaching local output data to send data during
slave operation

---

❍

❍

Attaching local I/O monitor data to send data during
slave operation

---

❍

❍

Functions to communicate with devices existing on
other networks
(Off-Link connection)

---

❍
(Unit version 2.0 or higher)

❍
(Unit version 2.0 or higher)

-----

❍

❍

❍

❍

-------

-------

-------

-----

-----

-----

---

---

---

Using overall Unit status in logic programming
Program execution wait functions

---

I/O control functions
Monitoring contact operation counter
Mounting total ON time monitor
DeviceNet communications functions

System startup and error recovery functions
Storing log of nonfatal errors in nonvolatile memory
Adding function block errors to error log
Ethernet/IP communications functions
I/O communications
Message communications
Read/write of target I/O area
Routing between DeviceNet and EtherNet/IP
I/O routing
Message routing
UDP/IP message communications functions
Message communications by UDP/IP

6

NE1A-SCPU Series
Unit Versions and Network Configurator Versions
Network Configurator version 2.0@ or higher must be used when using a NE1A-SCPU01-V1 or NE1A-SCPU02 Safety Logic Controller with unit
version 2.0.
❍ : Applicable, ×: Not applicable
Model

Network Configurator
Ver. 1.3@

Ver. 1.5@

Ver. 1.6@

Ver. 2.0@/2.1@

Ver.2.2@

Ver.3.3@

NE1A-SCPU01
Pre-Ver. 1.0

❍

❍

❍

❍

❍

❍

NE1A-SCPU01-V1
Unit version 1.0

×

×

❍

❍

❍

❍

NE1A-SCPU02
Unit version 1.0

×

×

❍

❍

❍

❍

NE1A-SCPU01-V1
Unit version 2.0

×

×

❍ (*1)

❍

❍

❍

NE1A-SCPU02
Unit version 2.0

×

×

❍ (*1)

❍

❍

❍

*1: It can be used as unit version 1.0.
Note: 1. Users who use Network Configurator version 1.5@ or earlier can upgrade to version 1.6@ at no charge.
2. When using Network Configurator version 1.6@, there are no operational differences in the NE1A-SCPU01-V1 and NE1A-SCPU02.

7

Terms and Conditions Agreement
Read and understand this catalog.
Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you
have any questions or comments.
Warranties.
(a) Exclusive Warranty. Omron’s exclusive warranty is that the Products will be free from defects in materials and workmanship
for a period of twelve months from the date of sale by Omron (or such other period expressed in writing by Omron). Omron
disclaims all other warranties, express or implied.
(b) Limitations. OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, ABOUT
NON-INFRINGEMENT, MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE OF THE PRODUCTS. BUYER
ACKNOWLEDGES THAT IT ALONE HAS DETERMINED THAT THE
PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE.
Omron further disclaims all warranties and responsibility of any type for claims or expenses based on infringement by the
Products or otherwise of any intellectual property right. (c) Buyer Remedy. Omron’s sole obligation hereunder shall be, at
Omron’s election, to (i) replace (in the form originally shipped with Buyer responsible for labor charges for removal or
replacement thereof) the non-complying Product, (ii) repair the non-complying Product, or (iii) repay or credit Buyer an amount
equal to the purchase price of the non-complying Product; provided that in no event shall Omron be responsible for warranty,
repair, indemnity or any other claims or expenses regarding the Products unless Omron’s analysis confirms that the Products
were properly handled, stored, installed and maintained and not subject to contamination, abuse, misuse or inappropriate
modification. Return of any Products by Buyer must be approved in writing by Omron before shipment. Omron Companies shall
not be liable for the suitability or unsuitability or the results from the use of Products in combination with any electrical or
electronic components, circuits, system assemblies or any other materials or substances or environments. Any advice,
recommendations or information given orally or in writing, are not to be construed as an amendment or addition to the above
warranty.
See http://www.omron.com/global/ or contact your Omron representative for published information.
Limitation on Liability; Etc.
OMRON COMPANIES SHALL NOT BE LIABLE FOR SPECIAL, INDIRECT, INCIDENTAL, OR CONSEQUENTIAL DAMAGES,
LOSS OF PROFITS OR PRODUCTION OR COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS,
WHETHER SUCH CLAIM IS BASED IN CONTRACT, WARRANTY, NEGLIGENCE OR STRICT LIABILITY.
Further, in no event shall liability of Omron Companies exceed the individual price of the Product on which liability is asserted.
Suitability of Use.
Omron Companies shall not be responsible for conformity with any standards, codes or regulations which apply to the
combination of the Product in the Buyer’s application or use of the Product. At Buyer’s request, Omron will provide applicable
third party certification documents identifying ratings and limitations of use which apply to the Product. This information by itself
is not sufficient for a complete determination of the suitability of the Product in combination with the end product, machine,
system, or other application or use. Buyer shall be solely responsible for determining appropriateness of the particular Product
with respect to Buyer’s application, product or system. Buyer shall take application responsibility in all cases.
NEVER USE THE PRODUCT FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY OR IN LARGE
QUANTITIES WITHOUT ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS,
AND THAT THE OMRON PRODUCT(S) IS PROPERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE
OVERALL EQUIPMENT OR SYSTEM.
Programmable Products.
Omron Companies shall not be responsible for the user’s programming of a programmable Product, or any consequence
thereof.
Performance Data.
Data presented in Omron Company websites, catalogs and other materials is provided as a guide for the user in determining
suitability and does not constitute a warranty. It may represent the result of Omron’s test conditions, and the user must correlate
it to actual application requirements. Actual performance is subject to the Omron’s Warranty and Limitations of Liability.
Change in Specifications.
Product specifications and accessories may be changed at any time based on improvements and other reasons. It is our
practice to change part numbers when published ratings or features are changed, or when significant construction changes are
made. However, some specifications of the Product may be changed without any notice. When in doubt, special part numbers
may be assigned to fix or establish key specifications for your application. Please consult with your Omron’s representative at
any time to confirm actual specifications of purchased Product.
Errors and Omissions.
Information presented by Omron Companies has been checked and is believed to be accurate; however, no responsibility is
assumed for clerical, typographical or proofreading errors or omissions.
2013.12
In the interest of product improvement, specifications are subject to change without notice.

OMRON Corporation
Industrial Automation Company
http://www.ia.omron.com/

(c)Copyright OMRON Corporation 2013 All Right Reserved.



Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.6
Linearized                      : Yes
Encryption                      : Standard V2.3 (128-bit)
User Access                     : Print, Copy, Extract, Print high-res
XMP Toolkit                     : Adobe XMP Core 4.0-c316 44.253921, Sun Oct 01 2006 17:14:39
Create Date                     : 2007:10:24 17:13:47Z
Creator Tool                    : FrameMaker 7.2
Modify Date                     : 2013:12:04 11:41:25+09:00
Metadata Date                   : 2013:12:04 11:41:25+09:00
Format                          : application/pdf
Description                     : 
Creator                         : OMRON
Title                           : CSM_NE1A-SCPU_Series_DS_E_6_3
Keywords                        : 
Producer                        : Acrobat Distiller 8.2.6 (Windows)
Document ID                     : uuid:1308b4ee-2b96-40d0-9754-7e0580a3c2ff
Instance ID                     : uuid:d0801dbc-b118-478c-8dd5-14631628a242
Has XFA                         : No
Page Count                      : 8
Subject                         : 
Author                          : OMRON
EXIF Metadata provided by EXIF.tools

Navigation menu