Intermatic General Catalog 121623
81385-Catalog 81385-Catalog 81385-Catalog 078275 Batch3 unilog cesco-content
202465-Catalog 202465-Catalog 202465-Catalog 078275 Batch4 unilog cesco-content
213245-Catalog 213245-Catalog 213245-Catalog 078275 Batch5 unilog cesco-content
91770-Catalog 91770-Catalog 91770-Catalog 078275 Batch10 unilog cesco-content
2014-10-17
: Pdf 121623-Catalog 121623-Catalog 078275 Batch10 unilog
Open the PDF directly: View PDF .
Page Count: 152
Download | |
Open PDF In Browser | View PDF |
General Catalog WEATHERPROOF ENERGY CONTROLS PROFESSIONAL LIGHTING POOL & SPA CONTROLS SURGE PROTECTION CONSUMER PRODUCTS www.intermatic.com Providing a Brighter Solution™ A system is defined as a group of units, combined to form a whole, which operates in unison. Intermatic takes this definition one step further and combines complete communication with total connectivity. Instead of just putting forward a massive listing of part numbers, Intermatic provides its customers with a new approach to energy controls that combines six categories of products into singular solutions – helping everyone from distributors and electrical contractors to architects and designers provide their customers with smarter and more reliable energy control systems. WEATHERPROOF ENERGY CONTROLS PROFESSIONAL LIGHTING POOL & SPA CONTROLS Table of Contents SURGE PROTECTION Commercial/Industrial Applications . . . . . .6 Residential Applications . . . . . . . . . . . . . . .8 Merchandising Support . . . . . . . . . . . . . . .10 Weatherproof Products . . . . . . . . . . . . .13 Energy Controls . . . . . . . . . . . . . . . . . . .20 Professional Lighting . . . . . . . . . . . . . . .58 Pool & Spa Controls . . . . . . . . . . . . . . . .67 Surge Protection . . . . . . . . . . . . . . . . . . .87 Consumer Products . . . . . . . . . . . . . . .121 Cross Reference . . . . . . . . . . . . . . . . . . .146 CONSUMER PRODUCTS Icon Legend: Underwriters Laboratories Listed UL Component Recognized UL Tested to Both UL & CSA Standards Knockouts CSA Tested to Both CSA & UL Standards Temperature CSA Tested to UL Standards Shipping Weight Canadian Standards Association Approved Warranty Period Product Index 133PE1484A . . .70, 71, 72 156ET9402A . . . . . . . .45 156ET9403A . . . . . . . .45 178PA28A . . . . . . .70, 72 22T338GR . . . . . . . . . .39 22T535GR . . . . . . . . . .39 24EG5133 . . . . . . . . .115 2T1985GR . . . . . . . . . .38 2T2040GA . . . . . . . . . .38 2T2502GA . . . . . . . . . .38 2T2292GA . . . . . . . . . .38 2T2293GA . . . . . . . . . .38 2T2331GA . . . . . . . . . .38 2T2365GA . . . . . . . . . .39 2T2366GA . . . . . . . . . .39 2T2485GA . . . . . . . . . .38 2T2500GA . . . . . . . . . .38 2T308A . . . . . . . . . . . .39 2T511GA . . . . . . . . . .38 6ET1398GA . . . . . . . . .39 AG2401C . . . . . . . . . .119 AG2401C-IND . . . . . .119 AG2403C . . . . . . . . . .119 AG2803C . . . . . . . . . .119 AG4801 . . . . . . . . . .119 AG4803C . . . . . . . . . .119 AG6503C . . . . . . . . . .119 AG6503C-IND . . . . . .119 AG6503L . . . . . . . . . .119 AL10210 . . . . . . . . . . .61 AL102-5C . . . . . . . . . .61 AL111 . . . . . . . . . . . .61 AL115 . . . . . . . . . . . .61 AL1160 . . . . . . . . . . . .61 AL12210 . . . . . . . . . . .61 AL122-5C . . . . . . . . . .61 AL300BW . . . . . . . . . .60 AL300MTW . . . . . . . . .60 AL300RTW . . . . . . . . .59 AL300TPWS . . . . . . . .59 AL375V . . . . . . . . . . .61 AL380C . . . . . . . . . . .61 AL385V . . . . . . . . . . .61 AL395 . . . . . . . . . . . .61 AL395V . . . . . . . . . . .61 AL401 . . . . . . . . . . . .61 AL402 . . . . . . . . . . . .61 AL402TA . . . . . . . . . . .61 AL403 . . . . . . . . . . . .61 AL403TA . . . . . . . . . . .61 AL405 . . . . . . . . . . . .62 AL405V . . . . . . . . . . .62 AL406 . . . . . . . . . . . .62 AL406TA . . . . . . . . . . .62 AL407TA . . . . . . . . . . .62 AL408TA . . . . . . . . . . .62 AL409 . . . . . . . . . . . .62 AL409TA . . . . . . . . . . .62 AL425C . . . . . . . . . . .62 AL501 . . . . . . . . . . . .62 AL502 . . . . . . . . . . . .62 AL502DS . . . . . . . . . .62 AL502TA . . . . . . . . . . .63 AL506 . . . . . . . . . . . .63 AL508V . . . . . . . . . . .63 AL510V . . . . . . . . . . .63 AL521 . . . . . . . . . . . .63 AL550 . . . . . . . . . . . .63 AL550DS . . . . . . . . . .63 AL550TA . . . . . . . . . . .63 AL600MTW . . . . . . . . .60 AL600TPWS . . . . . . . .59 AL600TW . . . . . . . . . .59 AL60TW . . . . . . . . . . .60 AL8-12 . . . . . . . . . . . .61 AL900TPWS . . . . . . . .59 AL900TW . . . . . . . . . .59 C8815 . . . . . . . . . . . .30 C8835 . . . . . . . . . . . .30 C8845 . . . . . . . . . . . .30 C8865 . . . . . . . . . . . .30 C8866 . . . . . . . . . . . .30 CA3000 . . . . . . . . .56, 57 CA3500 . . . . . . . . .56, 57 CA3750 . . . . . . . . .56, 57 CA5000 . . . . . . . . .56, 57 CA5100 . . . . . . . . .56, 57 CA5500BR . . . . . . .56, 57 CA600 . . . . . . . . . .56, 57 CA7100 . . . . . . . . .56, 57 CA9000 . . . . . . . . .56, 57 CL1 . . . . . . . . . . . . .134 CL111R . . . . . . . . . .134 CL115 . . . . . . . . . . . .134 CL191 . . . . . . . . . . . .134 CL191K . . . . . . . . . . .134 CL191S . . . . . . . . . . .134 CL191V . . . . . . . . . . .134 CL280 . . . . . . . . . . . .134 CL305P . . . . . . . . . . .134 CL4 . . . . . . . . . . . . .134 CL501 . . . . . . . . . . . .134 CL503TA . . . . . . . . . .134 CL507 . . . . . . . . . . . .135 CL508 . . . . . . . . . . . .135 CL509 . . . . . . . . . . . .135 CL635P . . . . . . . . . . .135 CL635R . . . . . . . . . .135 CL635RK . . . . . . . . . .135 CL635RS . . . . . . . . . .135 CL711 . . . . . . . . . . . .135 CL801BC8 . . . . . . . . .135 CL802BSB6 . . . . . . . .135 CL802P7 . . . . . . . . . .135 CL803S2 . . . . . . . . . .135 CL8041 . . . . . . . . . . .136 CL9 . . . . . . . . . . . . .136 CL905 . . . . . . . . . . . .136 CL905K . . . . . . . . . . .136 CL9S . . . . . . . . . . . .136 CP150HPS . . . . . . . . .66 CS110P . . . . . . . . . .132 CS110TA . . . . . . . . . .132 CS120TA . . . . . . . . . .132 CS140K . . . . . . . . . .132 CS14P . . . . . . . . . . .132 CS17K . . . . . . . . . . .132 CS180C . . . . . . . . . .132 CS200C . . . . . . . . . .132 CS230R . . . . . . . . . .132 CS240 . . . . . . . . . . .132 CS330OB . . . . . . . . .132 CS508K . . . . . . . . . .132 CS508P . . . . . . . . . .133 CS508S . . . . . . . . . .133 CS508TA . . . . . . . . . .133 CS7AC1 . . . . . . . . . .133 CS7CT4 . . . . . . . . . .133 CS7E1 . . . . . . . . . . .133 DD150HPS . . . . . . . . .65 DD175MV . . . . . . . . . .65 DT121C . . . . . . . . . .125 DT17C . . . . . . . . . . .125 DT27C . . . . . . . . . . .125 E1010 . . . . . . . . . . . . .51 E1020 . . . . . . . . . . . . .51 E1120 . . . . . . . . . . . . .51 E1220 . . . . . . . . . . . . .51 E1221 . . . . . . . . . . . . .51 EH10 . . . . . . . . . . . . .37 EH40 . . . . . . . . . . . . .37 EI200 . . . . . . . . . . . . .50 EI200LA . . . . . . . . . . .50 EI200W . . . . . . . . . . .50 EI210 . . . . . . . . . . . . .50 EI205 . . . . . . . . . . . . .50 EI205W . . . . . . . . . . .50 EI205LA . . . . . . . . . . .50 EI215 . . . . . . . . . . . . .50 EI215W . . . . . . . . . . .50 EI215LA . . . . . . . . . . .50 EI210 . . . . . . . . . . . . .50 EI210LA . . . . . . . . . . .50 EI210W . . . . . . . . . . .50 EI220 . . . . . . . . . . . . .50 EI220LA . . . . . . . . . . .50 EI220W . . . . . . . . . . .50 EI230 . . . . . . . . . . . . .50 EI230LA . . . . . . . . . . .50 EI230W . . . . . . . . . . .50 EI500C . . . . . . . . . . . .53 EI500LAC . . . . . . . . . .53 EI500WC . . . . . . . . . . .53 EI600C . . . . . . . . . . . .51 EI600WC . . . . . . . . . . .51 EI600LAC . . . . . . . . . .51 EJ351C . . . . . . . . . . .126 EJ500AC . . . . . . . . . .126 EJ500C . . . . . . . . . . .126 ET100C . . . . . . . . . . . .40 ET100CM . . . . . . . . . .40 ET101C . . . . . . . . . . . .40 ET102C . . . . . . . . . . . .40 ET103C . . . . . . . . . . . .40 ET104C . . . . . . . . . . . .40 ET104CP . . . . . . . . . . .40 ET105C . . . . . . . . . . . .40 ET171C . . . . . . . . . . . .41 ET171CR . . . . . . . . . .41 ET173C . . . . . . . . . . . .41 ET174C . . . . . . . . . . . .41 ET175C . . . . . . . . . . . .41 ET279C . . . . . . . . . . . .41 ET70115C . . . . . . . . . .43 ET70115CR . . . . . . . . .43 ET70115CR24 . . . . . . .43 ET70215C . . . . . . . . . .43 ET70215CR . . . . . . . . .43 ET70215CR24 . . . . . . .43 ET70415CR . . . . . . . . .44 ET70415CR24 . . . . . . .44 ET70815CR . . . . . . . . .44 ET70815CR24 . . . . . . .44 ET71615CR . . . . . . . . .44 ET71615CR24 . . . . . . .44 ET7232M . . . . . . . . . .45 ET7232M1 . . . . . . . . .45 ET8015C . . . . . . . . . . .42 ET8015CPD82 . . . . . . .42 ET8015CR . . . . . . . . . .42 ET8115C . . . . . . . . . . .42 ET8115CPD82 . . . . . . .42 ET8115CR . . . . . . . . . .42 ET8215C . . . . . . . . . . .42 ET8215CPD82 . . . . . . .42 ET8215CR . . . . . . . . . .42 FD12HC . . . . . . . . . . .48 FD12HH . . . . . . . . . . .48 FD12HHW . . . . . . . . . .48 FD12HWC . . . . . . . . . .48 FD15MAC . . . . . . . . . .48 FD15MC . . . . . . . . . . .48 FD15MH . . . . . . . . . . .48 FD15MHW . . . . . . . . .48 FD15MWC . . . . . . . . .48 FD2H . . . . . . . . . . . . .48 FD2HW . . . . . . . . . . . .48 FD30MAC . . . . . . . . . .48 FD30MC . . . . . . . . . . .48 FD30MH . . . . . . . . . . .48 FD30MHW . . . . . . . . .48 FD30MWC . . . . . . . . .48 FD312HW . . . . . . . . . .48 FD32H . . . . . . . . . . . .48 FD32HW . . . . . . . . . . .48 FD34H . . . . . . . . . . . .48 FD34HW . . . . . . . . . . .48 FD36H . . . . . . . . . . . .48 FD36HW . . . . . . . . . . .48 FD415M . . . . . . . . . . .48 FD430M . . . . . . . . . . .48 FD430MW . . . . . . . . . .48 FD460M . . . . . . . . . . .48 FD460MW . . . . . . . . . .48 FD46H . . . . . . . . . . . .48 FD46HW . . . . . . . . . . .48 FD4H . . . . . . . . . . . . .48 FD4HW . . . . . . . . . . . .48 FD5M . . . . . . . . . . . . .48 FD5MW . . . . . . . . . . .48 FD60HH . . . . . . . . . . .48 FD60MAC . . . . . . . . . .48 FD60MC . . . . . . . . . . .48 FD60MH . . . . . . . . . . .48 FD60MHW . . . . . . . . .48 FD60MWC . . . . . . . . .48 FD6H . . . . . . . . . . . . .48 FD6HHW . . . . . . . . . . .48 FD6HW . . . . . . . . . . . .48 FF12HC . . . . . . . . . . .49 FF12HHC . . . . . . . . . .49 FF15MC . . . . . . . . . . .49 FF15MH . . . . . . . . . . .49 FF2H . . . . . . . . . . . . .49 FF30MC . . . . . . . . . . .49 FF30MH . . . . . . . . . . .49 FF312H . . . . . . . . . . .49 FF312HH . . . . . . . . . .49 FF315M . . . . . . . . . . .49 FF32H . . . . . . . . . . . .49 FF32HH . . . . . . . . . . .49 FF330M . . . . . . . . . . .49 FF34H . . . . . . . . . . . .49 FF34HH . . . . . . . . . . .49 FF360M . . . . . . . . . . .49 FF36H . . . . . . . . . . . .49 FF412H . . . . . . . . . . .49 FF415M . . . . . . . . . . .49 FF430M . . . . . . . . . . .49 FF460M . . . . . . . . . . .49 FF46H . . . . . . . . . . . .49 FF4H . . . . . . . . . . . . .49 FF5M . . . . . . . . . . . . .49 FF5MH . . . . . . . . . . . .49 FF60MC . . . . . . . . . . .49 FF60MHC . . . . . . . . . .49 FF6H . . . . . . . . . . . . .49 FF6HH . . . . . . . . . . . .49 FL035HPS . . . . . . . . . .65 FL050HPS . . . . . . . . . .65 FL050MH . . . . . . . . . .65 FL070HPS . . . . . . . . . .65 FL070MH . . . . . . . . . .65 FL100HPS . . . . . . . . . .65 FL100MH . . . . . . . . . .65 FL150HPS . . . . . . . . . .65 FL150MH . . . . . . . . . .65 FL150Q . . . . . . . . . . .66 FL175MH . . . . . . . . . .65 FL250HPS . . . . . . . . . .65 FL250MH . . . . . . . . . .65 FL300Q . . . . . . . . . . .66 FL400HPS . . . . . . . . . .65 FL400MH . . . . . . . . . .65 FL500Q . . . . . . . . . . .66 HA01C . . . . . . . . . . .123 HA02C . . . . . . . . . . .123 HA03C . . . . . . . . . . .123 HA04C . . . . . . . . . . .123 HA05C . . . . . . . . . . .124 HA06C . . . . . . . . . . .124 HA07 . . . . . . . . . . . .124 HA09C . . . . . . . . . . .124 HB1116R . . . . . . . . .128 HB112C . . . . . . . . . .126 HB113C . . . . . . . . . .126 HB114C . . . . . . . . . .126 HB31R . . . . . . . . . . .127 HB35R . . . . . . . . . . .127 HB51RC . . . . . . . . . .127 HB61RC . . . . . . . . . .127 HB77RC . . . . . . . . . .128 HB88RC . . . . . . . . . .128 IG11246 . . . . . . . . . .114 IG11266 . . . . . . . . . .114 IG11266BLK10 . . . . . .114 IG11466 . . . . . . . . . .114 IG1201EH . . . . . . . . .101 Intermatic’s headquarters and main manufacturing facilities in Spring Grove, Illinois... making quality products since 1891. Visit us on our website at www.intermatic.com for the most up to date information on Intermatic products. WEATHERPROOF • ENERGY CONTROLS • PROFESSIONAL LIGHTING • POOL & SPA • SURGE PROTECTION • CONSUMER 3 IG1201F20 . . . . . . . .113 IG1201LH . . . . . . . . .103 IG1240FMP3 . . . . . . .116 IG1240RC . . . . . . . . .116 IG1300-2T-1C . . . . . .116 IG1300-4T-2C . . . . . .116 IG141 . . . . . . . . . . . .114 IG141T . . . . . . . . . . .114 IG143 . . . . . . . . . . . .114 IG143T . . . . . . . . . . .114 IG1866A . . . . . . . . . .114 IG1C . . . . . . . . . . . . .118 IG1C3R . . . . . . . . . . .118 IG1CM . . . . . . . . . . .118 IG1SRMP . . . . . . . . .115 IG2012B15 . . . . . . . .114 IG20615 . . . . . . . . . .114 IG2066 . . . . . . . . . . .114 IG2083ECY . . . . . . . . .99 IG2083LYH . . . . . . . .103 IG2083YECA . . . . . . . .98 IG2083YEH . . . . . . . .101 IG2086 . . . . . . . . . . .114 IG20B12 . . . . . . . . . .114 IG2401ECS . . . . . . . . .99 IG2401EH . . . . . . . . .101 IG2401F20 . . . . . . . .113 IG2401LH . . . . . . . . .103 IG2401SECA . . . . . . . .98 IG2403DECA . . . . . . . .98 IG2403DEH . . . . . . . .101 IG2403ECD . . . . . . . . .99 IG2403LDH . . . . . . . .103 IG250LA . . . . . . . . . .120 IG251 . . . . . . . . . . . .117 IG2T . . . . . . . . . . . . .118 IG2T3R . . . . . . . . . . .117 IG2TM . . . . . . . . . . .117 IG3240FMP3 . . . . . . .116 IG3240RC . . . . . . . . .116 IG4803DECA . . . . . . . .98 IG4803DEH . . . . . . . .101 IG4803ECD . . . . . . . . .99 IG4803ECY . . . . . . . . .99 IG4803LDH . . . . . . . .103 IG4803LYH . . . . . . . .103 IG4803YECA . . . . . . . .98 IG4803YEH . . . . . . . .101 IG4TM . . . . . . . . . . .117 IG9638S55 . . . . . . . .114 IGFLUSH MOUNT KIT .118 K1121 . . . . . . . . . . . .24 K1122 . . . . . . . . . . . .24 K1221 . . . . . . . . . . . .24 K1222 . . . . . . . . . . . .24 K4021C . . . . . . . . . . .21 K4022 . . . . . . . . . . . .21 K4023C . . . . . . . . . . .21 K4024 . . . . . . . . . . . .21 K4027 . . . . . . . . . . . .21 K4033 . . . . . . . . . . . .21 K4035 . . . . . . . . . . . .21 K4121C . . . . . . . . . . .22 K4121M . . . . . . . . . . .22 K4122 . . . . . . . . . . . .22 K4123C . . . . . . . . . . .22 K4123M . . . . . . . . . . .22 K4124 . . . . . . . . . . . .22 K4127 . . . . . . . . . . . .22 K4133 . . . . . . . . . . . .22 K4135 . . . . . . . . . . . .22 K4136M . . . . . . . . . . .22 K4141C . . . . . . . . . . .22 K4221C . . . . . . . . . . .22 K4222 . . . . . . . . . . . .22 K4223C . . . . . . . . . . .22 K4224 . . . . . . . . . . . .22 K4233 . . . . . . . . . . . .22 K4235 . . . . . . . . . . . .22 K4236C . . . . . . . . . . .22 K4251 . . . . . . . . . . . .22 K4253 . . . . . . . . . . . .22 K4321C . . . . . . . . . . .21 K4421M . . . . . . . . . . .22 K4423M . . . . . . . . . . .22 K4521 . . . . . . . . . . . .23 K4522 . . . . . . . . . . . .23 K4524 . . . . . . . . . . . .23 K4533 . . . . . . . . . . . .23 K4535 . . . . . . . . . . . .23 K4536SS . . . . . . . . . .25 K4536SST . . . . . . . . . .25 LC2000 . . . . . . . . . . . .24 LC4521C . . . . . . . . . . .23 LC4521LA . . . . . . . . . .23 LC4523 . . . . . . . . . . . .23 LC4523LA . . . . . . . . . .23 LC4527 . . . . . . . . . . . .23 LC4535 . . . . . . . . . . . .23 LC4535LA . . . . . . . . . .23 LC4536LAC . . . . . . . . .23 LC4536C . . . . . . . . . . .23 4 LD622 . . . . . . . . . . .138 LD622L . . . . . . . . . . .138 LD641 . . . . . . . . . . .138 LT10 . . . . . . . . . . . . .136 LT13 . . . . . . . . . . . . .136 LT13N . . . . . . . . . . . .136 LT13S . . . . . . . . . . . .136 LT406 . . . . . . . . . . . .137 LT406N . . . . . . . . . . .137 LT8K . . . . . . . . . . . . .136 LT9 . . . . . . . . . . . . .136 LV103 . . . . . . . . . . . .138 LV108 . . . . . . . . . . . .138 LV181 . . . . . . . . . . . .138 LV183 . . . . . . . . . . . .138 LX1 . . . . . . . . . . . . .138 LX703 . . . . . . . . . . . .142 LX9Z . . . . . . . . . . . .138 LZ1 . . . . . . . . . . . . .141 LZ10130 . . . . . . . . . .141 LZ10131 . . . . . . . . . .141 LZ10131P . . . . . . . . .141 LZ11101OB . . . . . . . .139 LZ11101P . . . . . . . . .139 LZ11101RB . . . . . . . .139 LZ11101V . . . . . . . . .140 LZ11771H . . . . . . . . .140 LZ11771HK . . . . . . . .140 LZ13RP4 . . . . . . . . . .144 LZ14001H . . . . . . . . .140 LZ14001HP . . . . . . . .140 LZ15004 . . . . . . . . . .144 LZ16220 . . . . . . . . . .143 LZ16551 . . . . . . . . . .144 LZ191 . . . . . . . . . . . .139 LZ191K . . . . . . . . . . .139 LZ1W . . . . . . . . . . . .141 LZ1WU . . . . . . . . . . .144 LZ20601P . . . . . . . . .142 LZ21811K . . . . . . . . .140 LZ230 . . . . . . . . . . . .140 LZ280RP4 . . . . . . . . .144 LZ3 . . . . . . . . . . . . .141 LZ302 . . . . . . . . . . . .141 LZ303RB . . . . . . . . . .143 LZ305FP . . . . . . . . . .143 LZ305P . . . . . . . . . . .139 LZ306 . . . . . . . . . . . .144 LZ307 . . . . . . . . . . . .144 LZ308 . . . . . . . . . . . .144 LZ310 . . . . . . . . . . . .143 LZ312 . . . . . . . . . . . .142 LZ313 . . . . . . . . . . . .144 LZ314 . . . . . . . . . . . .143 LZ3W . . . . . . . . . . . .141 LZ406 . . . . . . . . . . . .140 LZ407 . . . . . . . . . . . .140 LZ413 . . . . . . . . . . . .142 LZ413RP4 . . . . . . . . .142 LZ414 . . . . . . . . . . . .142 LZ415 . . . . . . . . . . . .142 LZ419 . . . . . . . . . . . .143 LZ418 . . . . . . . . . . . .140 LZ422WBR . . . . . . . .140 LZ422W . . . . . . . . . .140 LZ4H . . . . . . . . . . . .141 LZ4HW . . . . . . . . . . .141 LZ4HWGR . . . . . . . . .141 LZ4M . . . . . . . . . . . .141 LZ4MK . . . . . . . . . . .141 LZ4MOB . . . . . . . . . .141 LZ501RP4 . . . . . . . . .144 LZ511A . . . . . . . . . . .143 LZ511B . . . . . . . . . . .143 LZ511C . . . . . . . . . . .143 LZ511R . . . . . . . . . . .143 LZ51GR . . . . . . . . . .139 LZ53RP4 . . . . . . . . . .144 LZ6 . . . . . . . . . . . . .141 LZ601 . . . . . . . . . . . .139 LZ602 . . . . . . . . . . . .139 LZ603 . . . . . . . . . . . .139 LZ604B . . . . . . . . . . .143 LZ635RP4 . . . . . . . . .144 LZ701 . . . . . . . . . . . .142 LZ701W . . . . . . . . . .142 LZ702 . . . . . . . . . . . .142 LZ702W . . . . . . . . . .142 LZ703W . . . . . . . . . .142 LZ704 . . . . . . . . . . . .142 LZ704W . . . . . . . . . .142 LZ705 . . . . . . . . . . . .142 LZ7052 . . . . . . . . . . .142 LZ706 . . . . . . . . . . . .143 LZ7CT4 . . . . . . . . . . .139 LZ7FC4 . . . . . . . . . . .139 LZ7Z6 . . . . . . . . . . . .139 LZ90004 . . . . . . . . . .144 LZB1 . . . . . . . . . . . .144 ML100T . . . . . . . . . .138 ML10401 . . . . . . . . .138 ML10781 . . . . . . . . .138 ML11183 . . . . . . . . .138 ML121RT . . . . . . . . .138 ML200RT . . . . . . . . .138 ML200RTW . . . . . . . .138 ML300RTW . . . . . . . .138 ML44T . . . . . . . . . . .138 ML600TW . . . . . . . . .138 ML60704 . . . . . . . . .138 ML60721 . . . . . . . . .138 ML60722 . . . . . . . . .138 ML60TW . . . . . . . . . .138 ML88T . . . . . . . . . . .138 ML900TW . . . . . . . . .138 ML90401 . . . . . . . . .138 ML90708 . . . . . . . . .138 ML91103 . . . . . . . . .138 MZ101 . . . . . . . . . . .145 MZ102 . . . . . . . . . . .145 MZ105 . . . . . . . . . . .145 MZ204G . . . . . . . . . .145 MZ301 . . . . . . . . . . .145 MZ501 . . . . . . . . . . .145 MZ902 . . . . . . . . . . .145 MZ904 . . . . . . . . . . .145 MZ951 . . . . . . . . . . .145 MZ952 . . . . . . . . . . .145 MZ953 . . . . . . . . . . .145 NA401 . . . . . . . . . . .133 NA501 . . . . . . . . . . .133 NE1C . . . . . . . . . . . .129 NE200C . . . . . . . . . .129 NE250C . . . . . . . . . .129 NE2C . . . . . . . . . . . .129 NE3BC . . . . . . . . . . .129 NE5C . . . . . . . . . . . .129 P1101 . . . . . . . . . . . .85 P1102FE . . . . . . . . . .83 P1102ME . . . . . . . . . .83 P1103FE . . . . . . . . . .83 P1103ME . . . . . . . . . .83 P1121 . . . . . . . . . . . .85 P1131 . . . . . . . . . . . .85 P1161 . . . . . . . . . . . .85 P1203FR . . . . . . . . . .83 P1261P . . . . . . . . . . .85 P1261PE . . . . . . . . . . .85 P1353ME . . . . . . . . . .70 P171-30 . . . . . . . . . . .28 P4243ME . . . . . . . . . .71 P7101ME . . . . . . . . . .83 P7102ME . . . . . . . . . .83 P7103ME . . . . . . . . . .83 PA114 . . . . . . . . . . . .86 PAV215 . . . . . . . . . . .86 PAV215C . . . . . . . . . . .86 PAV220 . . . . . . . . . . .86 PAV220C . . . . . . . . . . .86 PAV315 . . . . . . . . . . .86 PAV315C . . . . . . . . . . .86 PAV320 . . . . . . . . . . .86 PAV320C . . . . . . . . . . .86 PE1501RC . . . . . . . . . .73 PE153 . . . . . . . . . . . .72 PE153F . . . . . . . . . . . .72 PE153P . . . . . . . . . . .72 PE153PF . . . . . . . . . . .72 PE153PW . . . . . . . . . .72 PE153PWF . . . . . . . . .72 PE153W . . . . . . . . . . .72 PE153WF . . . . . . . . . .72 PE1541RC . . . . . . . . . .73 PE24VA . . . . . . . . . . .86 PE25300 . . . . . . . . . . .73 PE25300 . . . . . . . . . . .73 PE25K120V . . . . . . . . .69 PE25K240V . . . . . . . . .69 PE40K120V . . . . . . . . .69 PE40K240V . . . . . . . . .69 PE45343RC . . . . . . . . .68 PE45343RCT1 . . . .68, 78 PE45343RCT3 . . . .68, 78 PE650 . . . . . . . . . . . .68 PE950 . . . . . . . . . . . .68 PEDCELL . . . . . . . . . .69 PEDCHLR . . . . . . . . . .69 PF1102 . . . . . . . . . . . .80 PF1102M . . . . . . . . . .80 PF1102MT . . . . . . . . .80 PF1102T . . . . . . . . . . .80 PF1103 . . . . . . . . . . . .80 PF1103M . . . . . . . . . .80 PF1103MT . . . . . . . . .80 PF1103T . . . . . . . . . . .80 PF1112T . . . . . . . . . . .81 PF1202T . . . . . . . . . . .81 PF1222TB . . . . . . . . . .81 PG1000-208-3Y . . . . .105 PG1000-240-2S . . . . .105 PG1000-480-3D . . . . .105 PG1000-480-3Y . . . . .105 PG100-208-3Y . . . . . . .93 PG100-240-2S . . . . . . .93 PG100-240-3HLD . . . . .93 PG100-480-3DLL . . . . .93 PG100-480-3Y . . . . . . .93 PG1500-208-3Y . . . . .104 PG1500-240-2S . . . . .104 PG1500-480-3D . . . . .104 PG1500-480-3Y . . . . .104 PG20-208-3Y . . . . . . .102 PG20-240-2S . . . . . . .102 PG20-240-3HLD . . . . .102 PG20-480-3D . . . . . . .102 PG20-480-3Y . . . . . . .102 PG3000-208-3Y . . . . . .96 PG3000-240-2S . . . . . .96 PG3000-240-3HLD . . . .96 PG3000-480-3DLL . . . .96 PG3000-480-3Y . . . . . .96 PG3000-600-3D . . . . . .96 PG3000-600-3Y . . . . . .96 PG3500-208-3Y . . . . . .94 PG3500-240-2S . . . . . .94 PG3500-240-3HLD . . . .94 PG3500-480-3DLL . . . .94 PG3500-480-3Y . . . . . .94 PG3500-600-3D . . . . . .94 PG3500-600-3Y . . . . . .94 PG4001-208-3Y . . . . . .92 PG4001-240-2S . . . . . .92 PG4001-240-3HLD . . . .92 PG4001-480-3DLL . . . .92 PG4001-480-3Y . . . . . .92 PG4001-600-3D . . . . . .92 PG4001-600-3Y . . . . . .92 PG40-240-2S . . . . . . .100 PG40-208-3Y . . . . . . .100 PG40-240-3HLD . . . . .100 PG40-480-3D . . . . . . .100 PG40-480-3Y . . . . . . .100 PG4501-208-3Y . . . . . .91 PG4501-240-2S . . . . . .91 PG4501-240-3HLD . . . .91 PG4501-480-3DLL . . . .91 PG4501-480-3Y . . . . . .91 PG4501-600-3D . . . . . .91 PG4501-600-3Y . . . . . .91 PG5001-208-3Y . . . . . .90 PG5001-240-2S . . . . . .90 PG5001-240-3HLD . . . .90 PG5001-480-3DLL . . . .90 PG5001-480-3Y . . . . . .90 PG5001-600-3D . . . . . .90 PG5001-600-3Y . . . . . .90 PG60-208-3Y . . . . . . . .97 PG60-240-2S . . . . . . . .97 PG60-240-3HLD . . . . . .97 PG60-480-3DLL . . . . . .97 PG60-480-3Y . . . . . . . .97 PG80-208-3Y . . . . . . . .95 PG80-240-2S . . . . . . . .95 PG80-240-3HLD . . . . . .95 PG80-480-3DLL . . . . . .95 PG80-480-3Y . . . . . . . .95 PJB2175 . . . . . . . . . . .86 PJB4175 . . . . . . . . . . .86 PR3C . . . . . . . . . . . .129 PX100 . . . . . . . . . . . .79 PX100S . . . . . . . . . . .79 PX300 . . . . . . . . . . . .79 PX300S . . . . . . . . . . .79 PX600 . . . . . . . . . . . .79 PX600S . . . . . . . . . . .79 R8806P101C . . . . . . . .31 R8815P101C . . . . . . . .31 R8816P101C . . . . . . . .31 RC2163BE . . . . . . . . . .82 RC2163BFE . . . . . . . . .82 RC2163E . . . . . . . . . .82 RC2163FE . . . . . . . . . .82 RC2263BE . . . . . . . . . .82 RC2263E . . . . . . . . . .82 RC2403RT . . . . . . . . .82 RC613 . . . . . . . . . . . .84 RC613L . . . . . . . . . . .84 RC613R . . . . . . . . . . .84 RC615 . . . . . . . . . . . .84 RC939 . . . . . . . . . . . .84 SC240 . . . . . . . . . . .132 SG160K-208-3Y . . . . .109 SG160K-240-3HLD . . .109 SG160K-480-3D . . . . .109 SG160K-480-3Y . . . . .109 SG240K-208-3Y . . . . .108 SG240K-240-3HLD . . .108 SG240K-480-3D . . . . .108 SG240K-480-3Y . . . . .108 SG320K-208-3Y . . . . .107 SG320K-240-3HLD . . .107 SG320K-480-3D . . . . .107 SG320K-480-3Y . . . . .107 SM2200*1 . . . . . . . . .46 SM2200*16 . . . . . . . .47 SM2200*2 . . . . . . . . .47 SM2200*3 . . . . . . . . .47 SM2200*4 . . . . . . . . .47 SM2200*5 . . . . . . . . .47 SM2200*6 . . . . . . . . .47 SM2200*7 . . . . . . . . .47 SM2200*8 . . . . . . . . .47 SM4400*1 . . . . . . . . .47 SM4400*10 . . . . . . . .47 SM4400*11 . . . . . . . .47 SM4400*12 . . . . . . . .47 SM4400*13 . . . . . . . .47 SM4400*14 . . . . . . . .47 SM4400*16 . . . . . . . .47 SM4400*2 . . . . . . . . .47 SM4400*3 . . . . . . . . .47 SM4400*4 . . . . . . . . .47 SM4400*5 . . . . . . . . .47 SM4400*6 . . . . . . . . .47 SM4400*7 . . . . . . . . .47 SM4400*8 . . . . . . . . .47 SM4400*9 . . . . . . . . .47 SM6600*1 . . . . . . . . .47 SM6600*10 . . . . . . . .47 SM6600*16 . . . . . . . .47 SM6600*2 . . . . . . . . .47 SM6600*3 . . . . . . . . .47 SM6600*4 . . . . . . . . .47 SM6600*5 . . . . . . . . .47 SM6600*6 . . . . . . . . .47 SM6600*7 . . . . . . . . .47 SM6600*8 . . . . . . . . .47 SM6600*9 . . . . . . . . .47 SP130B . . . . . . . . . .130 SP230B . . . . . . . . . .130 SP440B . . . . . . . . . .130 SP500 . . . . . . . . . . .130 SP640B . . . . . . . . . .130 ST01AC . . . . . . . . . .126 ST01C . . . . . . . . . . .126 T10000R . . . . . . . .39, 74 T10004R . . . . . . . .74, 78 T10004RT1 . . . . . . . . .78 T10004RT3 . . . . . . . . .78 T101 . . . . . . . . . . . . .26 T10101R . . . . . . . . . . .74 T101B . . . . . . . . . . . .26 T101P . . . . . . . . . . . .26 T101R . . . . . . . . . . . .26 T102 . . . . . . . . . . . . .26 T102P . . . . . . . . . . . .26 T102R . . . . . . . . . . . .26 T103 . . . . . . . . . . . . .26 T103P . . . . . . . . . . . .26 T103R . . . . . . . . . . . .26 T104 . . . . . . . . . . . . .26 T10404R . . . . . . . . . . .74 T104-20 . . . . . . . . . . .36 T104P . . . . . . . . . . . .26 T104R . . . . . . . . . . . .26 T105 . . . . . . . . . . . . .26 T10604R . . . . . . . . . . .74 T106R . . . . . . . . . . . .26 T12404R . . . . . . . . . . .74 T1471BCR . . . . . . . . . .27 T1471BR . . . . . . . . . .27 T1472BR . . . . . . . . . .27 T1475BR . . . . . . . . . .27 T171 . . . . . . . . . . . . .27 T171CR . . . . . . . . . . .27 T172 . . . . . . . . . . . . .27 T173 . . . . . . . . . . . . .27 T173CR . . . . . . . . . . .27 T173R . . . . . . . . . . . .27 T174 . . . . . . . . . . . . .27 T174CR . . . . . . . . . . .27 T174R . . . . . . . . . . . .27 T175 . . . . . . . . . . . . .27 T176 . . . . . . . . . . . . .27 T1871BR . . . . . . . . . .27 T1905 . . . . . . . . . . . . .29 T1905E . . . . . . . . . . . .29 T1906 . . . . . . . . . . . . .29 T1975 . . . . . . . . . . . . .29 T1975E . . . . . . . . . . . .29 T1975ER . . . . . . . . . . .29 T1975R . . . . . . . . . . .29 T1976 . . . . . . . . . . . . .29 T1976R . . . . . . . . . . .29 T20004R . . . . . . . . . . .75 T2005 . . . . . . . . . . . . .33 T2006 . . . . . . . . . . . . .33 T21000R . . . . . . . . . . .75 T21001R . . . . . . . . . . .75 T21004R . . . . . . . . . . .75 T30000R5 . . . . . . . . . .76 T30004R . . . . . . . . . . .76 T30000R . . . . . . . . . . .39 T30401R . . . . . . . . . . .76 T30404R . . . . . . . . . . .76 T30604R . . . . . . . . . . .76 T32404R . . . . . . . . . . .76 T40000R . . . . . . . .39, 77 T40000R4 . . . . . . . . . .77 T40003RT3 . . . . . . . . .78 T40004R5 . . . . . . . . . .77 T40004RSS . . . . . . . . .77 T40004RT1 . . . . . . . . .78 T40004RT3 . . . . . . . . .78 T40404R5 . . . . . . . . . .77 T51211BC . . . . . . . . . .32 T51311BC . . . . . . . . . .32 T7401B . . . . . . . . . . . .34 T7402B . . . . . . . . . . . .34 T7801B . . . . . . . . . . . .34 T7802B . . . . . . . . . . . .34 T8805P101C . . . . . . . .31 T8845PV . . . . . . . . . . .31 TB121C . . . . . . . . . . .125 TN111C . . . . . . . . . .125 TN111GC . . . . . . . . .125 TN311C . . . . . . . . . .125 TN711C . . . . . . . . . .125 TN811C . . . . . . . . . .125 TS100RS . . . . . . . . . .38 UG240R . . . . . . . . . .120 UG28A2083Y . . . . . . .112 UG28A2401S . . . . . . .112 UG28A2403D . . . . . . .112 UG28A4803D . . . . . . .112 UG28A4803Y . . . . . . .112 UG30A2083Y . . . . . . .111 UG30A2401S . . . . . . .111 UG30A2403D . . . . . . .111 UG30A2403G . . . . . . .111 UG30A4803D . . . . . . .111 UG30A4803Y . . . . . . .111 UG40A2083Y . . . . . . .110 UG40A2401S . . . . . . .110 UG40A2403D . . . . . . .110 UG40A2403G . . . . . . .110 UG40A4803D . . . . . . .110 UG40A4803Y . . . . . . .110 V45471CR . . . . . . . . . .35 V45471R . . . . . . . . . .35 V45472CR . . . . . . . . . .35 V45472R . . . . . . . . . .35 WH40 . . . . . . . . . . . . .36 WL035HPS . . . . . . . . .64 WL050HPS . . . . . . . . .64 WL050MH . . . . . . . . . .64 WL070HPS . . . . . . . . .64 WL070HPSPC . . . . . . .66 WL070MH . . . . . . . . . .64 WL100HPS . . . . . . . . .64 WL100MH . . . . . . . . . .64 WL150HPS . . . . . . . . .64 WL150MH . . . . . . . . . .64 WL175MH . . . . . . . . . .64 WL250HPS . . . . . . . . .64 WL250MH . . . . . . . . . .64 WL400HPS . . . . . . . . .64 WL400MH . . . . . . . . . .64 WP1000C . . . . . . . . . .19 WP1000GC . . . . . . . . .19 WP1000HC . . . . . .14, 19 WP1000HGC . . . . . . . .19 WP1000HRC . . . . . . . .16 WP1000RC . . . . . . . . .16 WP101 . . . . . . . . . . . .18 WP1010C . . . . . . . . . .19 WP1010HC . . . . . .14, 19 WP1010HMC . . . . .17, 19 WP1010MC . . . . . .17, 19 WP102 . . . . . . . . . . . .18 WP1020C . . . . . . .14, 19 WP103 . . . . . . . . . . . .18 WP1030C . . . . . . .14, 19 WP1030MC . . . . . .17, 19 WP1050 . . . . . . . .14, 19 WP107 . . . . . . . . . . . .18 WP1100C . . . . . . .14, 19 WP1100WC . . . . . . . . .19 WP1110C . . . . . . .14, 19 WP1110WC . . . . . . . . .19 WP1150C . . . . . . .14, 19 WP1220C . . . . . . .14, 19 WP1230C . . . . . . .14, 19 WP1250C . . . . . . .14, 19 WP17 . . . . . . . . . . . . .18 WP2000 . . . . . . . . . . .16 WP213 . . . . . . . . . . . .18 WP217 . . . . . . . . . . . .18 WP3100 . . . . . . . .14, 15 WEATHERPROOF • ENERGY CONTROLS • PROFESSIONAL LIGHTING • POOL & SPA • SURGE PROTECTION • CONSUMER Grounded in a tradition of innovation and service In 1891, Intermatic began producing portable fare registers for streetcars. Over the next 115 years, Intermatic developed a huge variety of products that have increased the safety, productivity and convenience of homes and businesses around the world. Driven by new technology and the needs of our customers Today, Intermatic is the leading supplier of high quality energy control products for industrial and commercial markets — moving into the 21st century with an extensive line of technology-driven products backed by an unparalleled level of customer service. Based on improving convenience and safety Intermatic is committed to making life productive, convenient and safe through the innovative use of electrical current. Continual product innovation, creative marketing and effective brand management makes Intermatic the most pioneering company within the wholesale distribution channel. Your total energy management solution Through our family of products, Intermatic provides a total solution for your energy management issues. Through our family of expert sales, training and technical personnel, Intermatic provides complete sales and marketing support. 5 6 Commercial and Industrial Applications Intermatic has everything contractors, maintenance personnel and plant or facility managers need to keep their factories, centers and businesses running at their peak. Intermatic Commercial and Industrial Applications • • • • • Interior and exterior lighting control Parking lot lighting control Mechanical time switches Electronic time switches Service entrance and panelboard surge protection • Point-of-use surge protection • Exterior receptacle protection • Landscape lighting Intermatic has a full line of commercial and industrial products needed to reduce electricity and labor costs and decrease power quality problems. Small investments in Intermatic energy controls and surge protection can: • Increase energy savings • Increase up-time • Increase productivity • Increase data retention Whether it’s part of a manufacturing, distribution or office environment, Intermatic offers a broad line of commercially related products for: • High amperage/voltage machinery • Heavy duty pumps • Motors • Variable frequency drives • HVAC systems In addition to a broad range of products, Intermatic provides complete bid specifications and wiring diagrams for every model and each product is backed up by the industry’s best sales support and technical assistance team. ™ For more than a century, Intermatic has been a premier supplier of commercial and industrial products and has Z-WAVE developed a reputation for providing its customers with innovative products that far exceed their expectations. The new InTouch Wireless Controls™ line of home controls will serve as the primary link to the Intermatic System. Brought to life with Z-Wave™ technology, InTouch Wireless Controls™ will help our customers grow their business within the booming home controls industry and will help home and business owners achieve higher levels of convenience, security and safety. 7 Residential Applications Whether you’re an electrical contractor, homebuilder or homeowner, Intermatic is the only name you need to know for increased levels of convenience, safety, security and electronic protection. Intermatic Residential Applications • • • • • • • • Interior and exterior lighting control Whole home energy controls Whole home surge protection Home office and home theatre surge protection Pool and spa controls Landscape lighting Exterior receptacle protection Security floodlighting With electricity costs on the rise and power quality problems at an all time high, Intermatic has a full line of residential products needed to combat these issues. A minor investment in energy controls and surge protection can prove to have major long-term cost savings and home appliance/electronic preservation. Intermatic residential products provide homeowners with multiple benefits, including: • Whole home energy savings • Lighting automation to increase the beauty, Safety and security of your home • Surge protection for home appliances and electronics • Landscape lighting to accent your home and property • Pool and spa controls for improved cost savings and convenience Intermatic provides the home building industry with the most comprehensive offering of residential energy control and surge protection products. Intermatic also offers weatherproof products, pool and spa controls and low voltage landscape lighting. Intermatic products can be used through a home and the surrounding property, including: • Garages and outbuildings • Landscaping • Entrances • Kitchens and bathrooms • Home offices and entertainment centers • Pool and spas Intermatic has developed two marketing programs to benefit those within the residential market: • Intermatic Authorized Installer Program helps contractors up-sell during a service call. • InGenius Homebuilder Program helps builders of new homes increase their add-on opportunities. Z-WAVE™ The future of the digital home is closer than we realize. Intermatic has a growing list of home control products that work together to enhance the safety, security and convenience of our complex and eventful lives. Intermatic has the knowledge, ability and resources to revolutionize home automation. 8 9 Intermatic provides you with everything you need in order to draw, secure and maintain steady sales growth Opportunities include: • Advanced Sales Support • Sales Incentives • Sales Training • Sales Programs and Promotions • Merchandising • Interactive Web Site The Industry’s Best Sales Support Our distributor sales training includes ways to best merchandise and up-sell our wide array of products. Training takes place at local, regional and national trade shows. In addition, Intermatic holds regular counter days and product “lunch and learns,” hosted by our direct sales personnel and sales agents, on location at local distributors. Call 800-391-4555 for toll-free technical support and assistance with programming, installation or application questions. Intermatic also works with engineers and specifiers and holds seminars for them on InTouch Wireless Controls™, surge supression products and Next Generation time switches. Contact your local Intermatic sales representative or visit www.intermatic.com. Intermatic’s order service support is set up to allow distributors and OEM customers to receive product when, where and how they want it. Drop shipments, multi-location shipments, blanket orders, express shipping and ship complete orders are complemented by a variety of other order support services. Our highly trained customer service representatives can also provide you with support for technical questions and applications by calling 815-675-7000 between 8:00 a.m. and 4:30 p.m. CST, Monday through Friday. 10 Intermatic Merchandising/Support Customized Sales Incentives Regular sales spiffs for sales and counter personnel are designed to motivate the seller and push product at every level. Customized sales support literature can also be designed for local made-to-order programs. Motivational Sales Programs and Promotions Intermatic is a total business partner and backs the sale of its products with innovative programs and promotions at every level, with support provided to distributors, contractors and home builders. Comprehensive Sales Training Providing you with the industry’s best electrical products is step one. Helping you get those products into the hands of your customer is step two. The best way to make that happen is to supply you with specific information on how to sell and up-sell within our five categories of products. On site or at the counter, Intermatic gives you the answers to frequently asked questions and provides you with good, better and best scenarios and competitive comparisons in order to help you help your customers make the best buying decision. • The Power-Plus Program for distributors increases their margins and inventory turns while lowering their transaction costs. • The Authorized Installer Program helps contractors add to their bottom line by up-selling and installing additional products during service calls. • The InGenius Program helps home builders sell upgrades at model homes and in the sales office. Merchandising items include: • Plan-o-grams • Header cards • Floor, wall and counter displays • Self shipper displays • P.O.P. displays • Countermats • Banners • Spec and cross reference CDs • Product demo and literature CDs Interactive Web Site Marketing Intermatic’s e-marketing program utilizes the Internet to provide fast, efficient, 24/7 communications with both distributors and end users. Intermatic’s Web site includes: • Authorized distributor locator • Authorized installer locator Intermatic also provides a regular selection of promotions that include shipper/displays, product introductions, contractor bonus packs and Intermatic branded merchandise. • Downloadable specifications, wiring diagrams and instruction manuals • E-mail technical support • General catalog (downloadable PDF) • Warranty registration Thought-provoking Merchandising Eighty percent of walk-in customers will buy additional products, if merchandising is done effectively. Sixty-five percent of all purchases are affected by displays and visual graphics. That is why Intermatic has invested heavily in merchandising resources in order to boost your return on investment. Intermatic’s Industrial Merchandising program provides you with the support and information you need to achieve maximum results, increase impulse purchases and build effective displays. In the future, a variety of enhancements will be implemented that will include improved navigation, product search by category or model number, competitive product search, ordering of product literature and an events/news page. Also, a new secured-access distributor intranet will provide additional product education and sales training, distributor spec sheets, pricing and promotions, a job-quoting tool and a discussion board. For more information on Intermatic sales support, programs and promotions, contact your local Intermatic sales representative, visit www.intermatic.com or call 815-675-7000 between 8:00 a.m. and 4:30 p.m. CST, Monday through Friday. 11 Five reasons to keep your eye on Intermatic Superior New Product Developments Intermatic is able to leverage its global and technological resources to provide its customers with products full of innovative features and benefits and maintain its first-to-market stature. World-class Global Manufacturing The Intermatic family is made up of a global workforce, who through lean manufacturing methods, produce the world’s finest energy control products. Excellent Supply Chain Management Regardless of its substantial growth, Intermatic has remained flexible and responsive and completely customer focused. At Intermatic, intensive quality control and on-time deliveries are customary. Complete Sales and Marketing Support Over the course of the year, Intermatic helps promote its products through a variety of sales incentives, promotions and merchandising campaigns. We also offer distributor training and technical support at every level. Superior Enterprise Information Systems Flexible, Web-based information gives us a competitive advantage and real-time information keeps us up to date to help take better care of our customers. 12 Your Outdoor Needs are Covered Often times, the simplest things in life make the biggest impact. Intermatic understands that simple measures can have a big effect in protecting the electrical systems and products within your home or business. Intermatic has designed a line of hard wearing weatherproof products that provide an exact match to the application, are easy to install and provide reliability and longevity. Our full line of weatherproof products are the perfect combination of utility and innovation. From our patented Flexi-Guard covers to our heavy duty die-cast outlet boxes, lamp holders and fittings, Intermatic has you completely covered from start to finish. Intermatic also makes it easy to stay current with the latest electrical codes and all models comply with 2002 NEC Article 250.146, which provides direct mounting of wiring devices to the switch box. We have the best coverage in the industry and are constantly updating our product categories to meet your ever-changing needs and requirements. As new codes and articles are being introduced and enforced, Intermatic will have the box, cover or accessory you need to remain compliant. 13 Weatherproof Receptacle Covers with Patented Insert Design These NEMA 3R receptacle covers ensure compliance with 2005 NEC Article 406.8 (B) (1) which requires that 15 and 20 ampere, 125 and 250 volt receptacles installed in a wet location have an enclosure that is weatherproof whether or not the attachment plug cap is inserted. They also meet the 1999 NEC Article 410-57(b) and are designed to meet the 1999 NEC Article 210-60(b), which requires that receptacles installed behind beds in hotels and motels be protected with a suitable guard. All covers are shipped with gasket, mounting screws, base and cover assembly and patented inserts. The Flexi-Guard series provides inserts for a variety of applications; 16 for the WP3100/WP1100 single gang series and 70 for the WP1200 two gang series. The single gang Flexi-Guard models are all designed to mount horizontally or vertically. The patented insert design ensures flexibility in the field by simply inserting the proper insert into the base and cover assembly. The two gang Flexi-Guard models utilize six “split” inserts which create virtually any dual device combination, as well as providing additional flexibility because the inserts can be rotated 90, 180 or 270 degrees. This provides coverage for horizontally or vertically mounted devices as well as “left hand” or “right hand” applications without removing and switching the two installed devices. The “jumbo covers” WP1150C, WP1250C, WP1050 and WP1050G provide protection for a single large cord set (up to 3/4" dia.) for portable spa heaters and other heavy duty applications. A lockable hasp is provided on selected models. The hasp accepts up to .315" (8 mm) diameter shank. NEMA 3R Meets UL and CSA Cold Impact Testing at -60˚F (-51˚C) Patented: U.S. Patent #5 280 135 U.S. Design Pat. #342233 Canadian Patent #2 073 932 Other Patents Pending Waterproof Cover Applications • Vending Machines • RV Connectors • Sprinkling Controls • Car Lot Lighting • Car Washes • Food Preparation • Hotel Applications • Amusement Equipment • Seasonal Lighting • Drinking Fountains • Gate Controls • Low Voltage Lighting • Plant Grow Lighting • Scoreboard Controls • Ventilating Fans • Remote Power Needs • Athletic Field Lighting • Process Start Up • Meat Processing • Plant Watering • Landscape Lighting • Portable Spas • Score Board Controls • Equipment • Engine Block Heaters • Remote Feeders • Outdoor Signs • Portable Marquee • Bug Zappers • Septic Lift Pumps • Holiday Lighting • Irrigation Pumps Specifications All covers for flushmount, surface mount or FS junction box mounting. Cover – Clear (gray or white on selected models) UV stabilized polycarbonate with two cord outlets 1/2" (12.7 mm) Wide by 9/16" (14.2 mm) High. Models WP1150C, WP1250C and WP1050 one cord outlet 3/4" (19.1 mm) Wide by 1-5/16" (33.3 mm) High. Mounting Base and Inserts – Black UV stabilized polycarbonate. Gasket – Neoprene - 1/8" (4.8 mm) thick with slits for mounting screws. Shipping Weight – WP3100C – .45 lbs. (0.20 kg) WP1100C / WP1000HC – .38 lbs. (0.17 kg) WP1110C / WP1010HC – .41 lbs. (0.19 kg) WP1150C / WP1230C / WP1030C – .75 lbs. (0.34 kg) WP1220C / WP1020C – .72 lbs. (0.33 kg) WP1250C / WP1050 – .9 lbs. (0.41 kg) UL514D E142193 14 C22.2-42.1 LR88576 WEATHERPROOF • ENERGY CONTROLS • PROFESSIONAL LIGHTING • POOL & SPA • SURGE PROTECTION • CONSUMER Weatherproof Receptacle Covers with Patented Insert Design WP3100C - Vertical/Horizontal Cover Flexi-Guard Weatherproof While-In-Use Cover Product Features • Complies with 2005 NEC® Article 406.8(B)(1): “15 and 20 Ampere, 125 and 250V receptacles installed in wet locations shall have an enclosure that is weatherproof whether or not the attachment plug cap is inserted” • Easy to remove cord set exit ports APPLICATIONS Provides an attractive, code compliant solution for protecting while-in-use outdoor receptacles. SPECIFICATIONS • Mounts Vertically or Horizontally • Hidden Hinges • Three patented inserts for GFCI, Duplex, Toggle and Single Receptacles • Inserts include keyhole slots for 16 installation configurations • Pre-adhered gasket • Heavy-duty polycarbonate construction • Clear Cover • Gray Base • Meets requirements for cold impact testing at -60º F (-51ºC) • Lockable hasp for 1/8” shank lock GFCI DEVICE SHOWN NOT INCLUDED Warranty: Limited 1-year warranty 1.00 lbs 0.45 kg WEATHERPROOF • ENERGY CONTROLS • PROFESSIONAL LIGHTING • POOL & SPA • SURGE PROTECTION • CONSUMER 15 Weatherproof Receptacle Covers with Patented Insert Design WP1000RC - Vertical Cover WP1000HRC - Horizontal Cover Recessed Weatherproof While-In-Use Cover Product Features • Complies with 2005 NEC® Article 406.8(B)(1) • Heavy duty, polycarbonate cover for long lasting durability APPLICATIONS Provides an attractive, code compliant solution for protecting while-in-use outdoor receptacles. GFCI DEVICE SHOWN NOT INCLUDED SPECIFICATIONS • Device installs recessed in wall for a flush finish for Siding, Stucco or Brick finishes • Removable siding flange provides clear finish for all siding types • Patented single gang inserts for GFCI, duplex, single receptacles, toggle switch and blank • Heavy Duty Gasket ensures protection from the elements • Recessed Sleeve adjusts to ensure lowest profile installation in every application • Outlet box offers mounting options for stud, block, brick or cut-in • Cord exit easily handles two 12/3 cord sets • Handles romex or conduit installations • Wider access to device for easy cord set installation • Heavy duty, UV resistant, polycarbonate constructed cover 2.00 lbs 0.91 kg Warranty: Limited 1-year warranty WP2000 Flexi-Guard Outlet Post Weatherproof While-In-Use Cover PRODUCT FEATURES • Complies with 2005 NEC® Article 406.8(B)(1) • Heavy duty PVC construction for long lasting durability APPLICATIONS Provides a new, code compliant solution for supplying power to gardens and other out-of-the-way areas. A remotely mounted energy saving photo control and/or timer also available to activate area lighting SPECIFICATIONS GFCI DEVICE SHOWN NOT INCLUDED • Patented single gang inserts for GFCI, duplex, single receptacles, toggle switch and blank • Provisions for installing mechanical or digital timers to control area lighting: – PB912M10R: 24 hour, 120 Volt mechanical timer – allows for 2 ON/OFF daily cycles – PB313K: 24 hour, 120 Volt electronic timer – allows for 8 ON/OFF daily cycles (Timers sold separately) • Provisions for fixed-position, stem-mounting and stem & swivel mounting photo controls to control area lighting • All ports accept 1/2”,3/4”, or 1” PVC conduit (adapters included) • Base includes mounting holes and template for optional concrete/pavement mounting • Cover includes lockable hasp Warranty: Limited-1 year warranty 3.00 lbs 1.36 kg 16 WEATHERPROOF • ENERGY CONTROLS • PROFESSIONAL LIGHTING • POOL & SPA • SURGE PROTECTION • CONSUMER Weatherproof Receptacle Covers Die Cast These heavy duty die cast receptacle covers ensure compliance with the National Electrical Code (NEC). These models offer the same features as the plastic models but are manufactured of heavy duty cast metal for severe applications such as schools and commercial buildings. The two gang model WP1030MC includes inserts for double gang duplex and GFCI requirements. This patented insert design uses the same inserts as all WP1000 series weatherproof covers and provides flexibility in the field by selecting and inserting the proper insert. For other applications see insert listing below. All models are recommended for 14 gauge or lighter cord sets. A lockable hasp is provided (lock not included). The hasp accepts up to .315" (8 mm) diameter shank. Specifications Cover – Gray die cast metal Mounting Base – Gray die cast metal with cord outlets 1" (25.4 mm) Wide by 5/8" (15.9 mm) High; one for models WP1010MC and WP1010HMC and two for model WP1030MC. Inserts – Black UV stabilized polycarbonate. Gasket – Neoprene 1/8" (3.2 cm) thick with slits for mounting screws. Shipping Weight – WP1010MC – 0.8 lbs. (0.36 kg) WP1010HMC – 0.9 lbs. (0.41 kg) WP1030MC – 1.1 lbs. (0.5 kg) All models comply with 2005 NEC Article 250.146 which provides direct mounting of wiring devices to the switch box. UL514D E142193 C22.2-42.1 LR88576 WEATHERPROOF • ENERGY CONTROLS • PROFESSIONAL LIGHTING • POOL & SPA • SURGE PROTECTION • CONSUMER 17 Now you can handle even more with less. Inserts Inserts fit single gang models and two gang models of clear, gray or die cast design. The 2-gang inserts for models WP1020, WP1030, WP1020GC, WP1030GC, WP1030MC and WP1050 can be mounted at any angle 90, 180 or 270 degrees from that shown. Additional hardware, if required, and special 2-gang gasket is packaged with 2-gang (WP200 series) inserts. 16 Configurations for Single Gang WP1100C Series Intermatic Flexi-Guard Weatherproof Receptacle Covers let you handle even more configurations with fewer units. The unique patented inserts and covers allow you to keep even less inventory than before, and cover more jobs out in the field. Our single gang models handle both vertical or horizontal applications, just by changing the hinge points. Our two-gang models include snap-together, rotating inserts that create combinations for almost every application. With these new Flexi-Guard models, now more than ever, Intermatic is the best NEC code solution under the sun. New Features Single gang plastic models feature pre-adhered gaskets and all covers feature keyhole slots on inserts for the quickest installation available Clear & Opaque Gray Models 70 Configurations for Double Gang WP1200C Series 3-1/2" 2-5/8" WP1010 3-1/2" WP1000 2-5/8" WP1030/WP1230C 3-1/2" WP1020/1220C 2-5/8" WP1050/WP1250C 4-1/4" 5-1/2" 5-1/2" 4-7/8" WP1010H WP1000H 6" 5" 3-13/16" 5" 5" Clear & White Models 4-3/4" 3-1/2" 2-7/8" 34-7/8" WP1030/WP1230C 3-1/2" WP1020/1220C 2-5/8" WP1150C WP1110C WP1100C WP1050/WP1250C 6" 5-1/2" 5-3/8" 5" 5" 3-1/2" Heavy Duty Die Cast Models 3-1/4" 2-1/2" 3-1/4" 2-1/2" WP1030MC 3-1/4" 2-1/2" WP1010MC WP1010HMC 4-1/2" 6-1/2" 6-1/2" Additional inserts available for Flexi-Guard or Guardian Series 5-3/4" 3-3/4" 5-9/16" Outlet Post Recessed WP2000 Two Gang Duplex Two Gang GFCI Two Gang Toggle Two Gang Round Two Gang Round WP101 WP102 WP103 WP107 WP213 WP1000RC FRONT VIEW BOTTOM VIEW SIDE VIEW 6-5/8” DIA 6.81 5.47 1.125 WP1000HRC 6.0 1.125 8.62 0.25 1.125 7.25 6.0 1.125 0.25 3.50 3.50 1-13/32” 9.43” 7.70 1-13/32” 5.90 5.88 6.81 8.62 WET LOCATIONS ONLY WHEN COVER CLOSED 1-13/32” 1-3/8” 1-5/8” 1-3/4” Single Gang Flexi-Guard WP17 † Converts to toggle, 1-3/8", 1-5/8", 1-3/4" or 2-1/8" diameter round 18 2-5/32” 2-21/32” 1-5/8” WET LOCATIONS ONLY WHEN COVER CLOSED 1-13/32” 1-5/8” 6.64” 8.17” Two Gang Flexi-Guard WP217 ‡ Converts to toggle, 1-3/8" or 1-5/8" diameter round Inset Design US Patent #5 280 135 Canadian Patent #2073932 WEATHERPROOF • ENERGY CONTROLS • PROFESSIONAL LIGHTING • POOL & SPA • SURGE PROTECTION • CONSUMER Now you can handle even more with less. Patented Single Gang Vertical or Horizontal 2-1/4” Standard Depth 2-3/4” Standard Depth Two Gang with Patented Patented Die Cast Metal Snap-Together Inserts Clear WP1220C Patented Two Gang Fixed Patented Single Gang Fixed Clear WP1020C Clear Gray WP1000C WP1000GC Vertical Vertical WP1000HC WP1000HGC Horizontal* Horizontal* Clear WP1030C Clear WP1010C Vertical WP1010HC Horizontal* Clear* White* WP1100C WP1100WC Vertical or Horizontal 3-1/8” Standard Depth 3-5/8” Standard Depth Grey Die Cast WP1010MC Vertical Single Gang WP1030MC Two Gang WP1010HMC Horizontal Single Gang Clear WP1230C Clear* White* WP1110C WP1110WC Vertical or Horizontal 4-3/4” Standard Depth Clear* WP1150C Clear* WP1250C Clear* WP1050 Vertical or Horizontal WP1100 Series Includes 3 Patented Inserts WP1200 Series Includes 6 Snap Together Patented Inserts WP1000MC Series Includes these Patented Inserts ‡ WP1000 Series Includes these Inserts WP1000 Series Includes these Inserts ‡ Two Gang † † † ‡ Single Gang * With lockable hasp † Converts to toggle, 1-3/8”, 1-5/8”, 1-3/4” or 2-1/8” diameter round ‡ Converts to toggle, 1-3/8” or 1-5/8” diameter round Insert Design US Patent #5 280 135 Canadian Patent #2073932 WEATHERPROOF • ENERGY CONTROLS • PROFESSIONAL LIGHTING • POOL & SPA • SURGE PROTECTION • CONSUMER 19 Giving You Total Control Within both home and work environments, Intermatic has been a leader in innovation for timing, switches and energy controls for more than 110 years. Intermatic provides the industry’s broadest line of energy controls, with ratings and innovative features designed to handle any industrial, commercial or residential application. Presently, the home controls industry is growing at an annual rate of 18 percent. Additionally, industry experts predict that the category of home controls could approach annual sales of $500 million. Intermatic sees this as a wonderful opportunity, not only to grow our business, but help you grow yours as well – through the best product offerings, programs and support at every step of the way. 20 Photo Controls A full line of thermal type photo controls and relay type photo controls provide “dusk-to-dawn” lighting control. The thermal type controls feature a cadmium sulfide photocell and sonic welded polycarbonate case and lens to seal out moisture. The design utilizes a dual temperature compensating bimetal and a metal film resistor for reliable long life operation over ambient temperature extremes. The thermal type photo controls provide a delay action which eliminates loads switching OFF due to car headlights, lightning, etc. K4021C Applications • Parking Lot Lighting • Billboard Lighting Model K4321C UL773A E42722 C22.2-55 LR38068 • Area Lighting • Municipal Lighting K4000 Series UL773A E42722 • Car Lot Lighting • Roadway Lighting • Security Lighting • Street Lighting 5 Year Warranty Fixed Position Mounting, Thermal Type — K4000C Series Designed to fit into a standard outlet box, a post lamp or wall packs. Model K4321 includes a weatherproof wall plate with neoprene gasket. The UL listing for this model applies to the entire plate assembly when properly mounted to an approved outdoor junction box. All other models are equipped with a 3/8"-18 threaded side mounting, locking nut and washer gasket. All models with 9" leads. Size – Plate - 4-1/2" (11.4 cm) High, 2-3/4" (7.0 cm) Wide; Mechanism - 1-5/16" (3.3 cm) W, 1-13/16" (4.6 cm) L, 13/16" (2.1 cm) D. K4321C Model # Watts Tungsten VA Ballast Amps Tungsten Amps Ballast Volts K4021C K4023C K4024 K4022 K4033 K4027*** K4035* K4321C** 1800 3100-4150 3100 3600 4150 5205 7200 1800 1000 1700-2300 1700 2000 2300 2880 4000 1000 15 15 15 15 15 15 15 15 8.3 8.3 8.3 8.3 8.3 8.3 8.3 8.3 120 208-277 208 240 277 347 480 120 Note: Wall plate with gasket available for other models; order No. K4001. * Not UL listed or CSA certified. ** Wall plate included. *** Certified by CSA to US and Canadian Standards. Specifications Unless noted otherwise, the specifications listed below apply to K4000, K4100, K4200, K4300 & K4500 Series. Size – See individual models. Most hard wired models supplied with 6" leads. K4000 fixed position models have 9" leads. Switch Rating – See chart for each series. Note that the ballast wattage rating is based upon a 50% power factor. Activation – 1 - 5 FC “ON”; 3 - 15 FC “OFF” (without shield on models with shield.) Color – Gray Shipping Weight – See individual models. Light Shield for K4000 Part Number 6LV1352 UL773A E42722 C22.2-55 LR38068 K4000 Series UL773A E42722 5 Year Warranty WEATHERPROOF • ENERGY CONTROLS • PROFESSIONAL LIGHTING • POOL & SPA • SURGE PROTECTION • CONSUMER 21 Photo Controls Stem Mounting, Thermal Type – K4100 Series K4121C This series features single and multivolt models in both stem mount and stem mount with a swivel. All models are equipped with a light level slide adjustment and provide a 1/2"-14 threaded stem. A washer gasket and locking nut are packaged with each photo control. Models with “M” suffix have heavy duty die cast housings. Model K4251 and K4253 have photo eye located on top and are designed for spot/flood type fixtures. Size – K4100 Series - 1-9/16" (4.0 cm) Square, 3" (7.6 cm) Long; K4200 Series - 1/2"-14 threaded swivel, 1-9/16" (4.0 cm) Square, 5-1/2" (14.0 cm) Long; Model K4236 - 5-3/4" (14.6 cm) High, 3" (7.6 cm) Diameter. Model # K4121M Watts Tungsten VA Ballast Amps Tungsten Amps Ballast Volts 1800 2000 1800 3100 3600 3100-4150 3100-4150 4150 5205 7200 2000-4625 3000 1000 1800 1000 1700 2000 1700-2300 1700-2300 2300 2880 4000 1800 3000 15 16.7 15 15 15 15 15 15 15 15 16.7 25 8.3 15 8.3 8.3 8.3 8.3 8.3 8.3 8.3 8.3 8.6 25 120 120 120 208 240 208-277 208-277 277 347 480 120 or 277 120 K4121C K4121M K4421M K4124 K4122 K4123C K4423M*** K4133 K4127**** K4135* K4136M **K4141C* K4423M * Not UL listed or CSA certified. ** 1 year warranty. *** Model K4423M replaces K4123M **** Certified by CSA to US and Canadian Standards. UL773A E42722 C22.2-55 LR38068 5 Year Warranty K4221C Stem & Swivel Mounting, Thermal Type – K4200 Series K4236C Model # Watts Tungsten VA Ballast Amps Tungsten Amps Ballast Volts K4221C K4224 K4222 K4223C K4233 K4227*** K4235* K4236C K4251*** K4253*** 1800 3100 3600 3100-4150 4100 5205 7200 1800-4150 1800 3100-4150 1000 1700 2000 1700-2300 2300 2880 4000 1000-2300 1000 1700-2300 15 15 15 15 15 15 15 15 15 15 8.3 8.3 8.3 8.3 8.3 8.3 8.3 8.3 8.3 8.3 120 208 240 208-277 277 347 480 120 or 208-277 120 208-277 * Not UL listed or CSA certified. ***Certified by CSA to US and Canadian Standards. K4251 22 UL773A E42722 C22.2-55 LR38068 5 Year Warranty C22.2-177 LR3730 WEATHERPROOF • ENERGY CONTROLS • PROFESSIONAL LIGHTING • POOL & SPA • SURGE PROTECTION • CONSUMER Photo Controls Locking-Type Mounting, Thermal Type — K4500 Series Easy to install; just plug in and twist. This series is equipped with standard 3-prong NEMA locking-type plug connections. Incorporates K4000 style thermal switch for reliable long life performance. Complies with ANSI C136.10. Size – 3-3/4" (9.5 cm) High, 3" (7.6 cm) Diameter. Model # Watts Tungsten VA Ballast Amps Tungsten Amps Ballast Volts K4521 K4524** K4522 K4533** K4535** 1800 3100 3600 4100 7200 1000 1700 2000 2300 4000 15 15 15 15 15 8.3 8.3 8.3 8.3 8.3 120 208 240 277 480 * Ballast rating meets UL testing at 50% power factor. ** Not CSA certified. UL773 E59121 C22.2-177 LR38068 3/4 lbs .34 kg K4521 5 Year Warranty Accessories for Locking-Type Controls Pole Bracket Adapter – Model K122 - 105 to 480 Volts; for use with K1200, K4500 or LC4500 Series locking-type controls. K121 – receptacle only, K121-30 receptacle with 30 inch leads. Shorting Cap – Model K4500 - 105 to 480 Volts; replaces locking-type photo control to complete circuit. K4500 K122 K121 K121-30 Low Cost Locking-Type, Thermal Type — LC4500 Series The LC4500 Series provides low cost reliable control for street lighting and other applications requiring a NEMA twist and lock type plug connection. An integral housing and lens, with UV protection, keeps moisture out and ensures long life. Complies with ANSI C136.10. Activation – .5 FC minimum “ON”; 15 FC maximum “OFF”. Size – 2-3/4" (7.0 cm) High, 3" (7.6 cm.) Diameter. Color – Translucent with color coded band for voltage identification. Model # Watts Tungsten VA Ballast Volts 1000 1700-2300 5205 1000 1000-2300 1000 1700-2300 1000 1000-2300 1000 1700-2300 2880 4000 1000-2300 1000 1700-2300 4000 1000-2300 120 208-277 347 480 120 or 208-277 120 208-277 480 120 or 208-277 LC4521C LC4523 LC4527 LC4535** LC4536C LC4521LA LC4523LA LC4535LA** LC4536LAC LC4521C LA Models equipped with 2400 volt open type spark gap arrester. * Ballast rating meets UL testing at 50% power factor. ** Not CSA certified. UL773 E59121 C22.2-55 LR38068 .2 lbs .09 kg 3 Year Warranty WEATHERPROOF • ENERGY CONTROLS • PROFESSIONAL LIGHTING • POOL & SPA • SURGE PROTECTION • CONSUMER 23 Photo Controls Relay Type Photo Controls With Adjustable Stem or Locking-Type Mounting — K1100, K1200 Series This series features “instant ON/OFF switching” in two mounting types. Complies with ANSI C136.10. K1200 Series K1100 – Equipped with an adjustable stem for mounting at almost any angle up to 80 degrees. Models equipped with three 6" color coded leads. Series K1200 – Easy to install using NEMA plug-in locking type connection. Models are equipped with 2400 Volt open type spark gap arrester and standard 3-prong connector. Size - K1100 Series – 5-3/4" (14.6 cm) High, 3" (7.6 cm) Diameter; 1/2"-14 NPT Stem; K1200 Series – 3-3/4" (9.5 cm) High, 3" (7.6 cm) Diameter. Activation – 1 FC “ON”; 3 - 10 FC “OFF” Model # Watts Tungsten VA Ballast Volts 1800 1800 1800 1800 1800 1800 1800 1800 105-130 210-240 105-130 210-240 K1121 K1122 K1221 K1222 * Ballast rating meets UL testing at 50% power factor. K1100 UL773 E59121 C22.2-55 LR38068 3/4 lbs .34 kg 5 Year Warranty UL773A E42722 Low Cost Relay Type Photo Control with Locking-Type Mounting — LC2000 Features “Instant ON/OFF Switching”. Complies with ANSI C136.10 Size - 2-3/16" (5.6 cm) High, 3-3/16" (8.1 cm) Diameter Activation – 1 to 3 FC “ON”. Turn OFF to turn ON ratio is 4. LC2000 Model # Watts Tungsten VA Ballast Volts LC2000 1000 1800 110-277 Includes 110 Joule MOV Surge Arrester. UL773 E59121 24 3/4 lbs .34 kg 3 Year Warranty WEATHERPROOF • ENERGY CONTROLS • PROFESSIONAL LIGHTING • POOL & SPA • SURGE PROTECTION • CONSUMER Photo Controls Solid State Photo Controls - Locking Type The K4536SS Photo Control is electronically calibrated and provides reliable control of street lighting and other applications requiring a NEMA plug-in locking type connection. Complies with ANSI C136.10. The K4536SST is the same as above, but provides a fixed “OFF” time adjustable in half hour increments from 6:00 PM to 2:00 AM and a fixed “ON” time adjustable in half hour increments from 4:00 AM to 8:00 AM. The fixed times are based on a real-time clock that sets itself based on the occurrence of sunrise and sunset. Operation – Instant “ON”, 10 Second Delay “OFF” Size - same as LC4500 Series Color - same as LC4500 Series Model # Watts Tungsten VA Ballast Volts K4536SS K4536SST 1000 1000 1800 1800 105-305 105-305 Includes 430 Joule MOV Surge Arrestor. UL773A E42722 3/4 lbs .34 kg K4536SS 5 Year Warranty K4536SST WEATHERPROOF • ENERGY CONTROLS • PROFESSIONAL LIGHTING • POOL & SPA • SURGE PROTECTION • CONSUMER 25 Time Switches 24 Hour Dial T100 Series – Designed for industrial, commercial and residential applications. Highest HP ratings in the industry for loads up to 40 amps, providing direct 24 hr. control of most loads. Provides 1 to 12 “ON/OFF” operations each day with minimum ON/OFF times of 1 hour. All models equipped with one “ON” and one “OFF” tripper. Applications • Indoor/Outdoor Lighting • Signs • Filters • Air Conditioning • Electric Fences • Heating/Ventilating Systems • Fans • Conveyers • Post Lanterns • Pool Heaters • Hydrochlorinators • Blowers • Pumps • Music and Signal Systems • Poultry Foggers Specifications Case – Drawn steel 7-3/4" (19.7 cm) H, 5" (12.7 cm) W, 3" (7.6 cm) D in gray finish. Spring hasp, with hole for lock, holds permanently attached, side hinged door closed. Three mounting holes on back plus handy box mounting holes. Knockouts – Combination 1/2"–3/4" nominal knockouts, one on back and each side of case and two on bottom. Optional Enclosures – See Time Switch Cases page for optional enclosures. Special Voltages and Cycles – See Time Switch Motors page for available motors. Switch Rating – Each Pole; 40 Amp Resistive, 120-480 VAC; 40 Amp Tungsten, inductive or 1000 VA pilot duty, 120-277 VAC; 2 HP (24 FLA) 120 VAC; 5 HP (28 FLA) 240 VAC single phase; 7-1/2 HP (28 FLA) 208 VAC three phase; 10 HP (28 FLA) 240 VAC three phase. Model # Model # w/See-Thru Cover Model # Plastic Case Model # Steel NEMA 3R Case T101 T102 T103 T104 T101B* T105 T106R† T101PCD82 –– T103PCD82 T104PCD82 –– –– –– T101P T102P T103P T104P –– –– –– T101R T102R T103R T104R Switch Clock Motor Volts 60 Hz AMPS (per pole) HP Rating SPST SPST DPST DPST SPST 1NO / 1NC** 1NO / 1NC** 125 208-277 125 208-277 125 125 208-277 40 40 40 40 40 40 40 2 5 2 5 2 2 5 * Separate clock motor terminals for switching circuits not on line voltage. ** Can be wired as SPDT. † Only available in NEMA 3R case. For additional trippers (1 ON / 1 OFF per pack), order No. 156T1978A. C22.2-177 LR3730 UL917 26 2.75 lbs 1.25 kg -40°F (-40°C) to 130°F (54°C) WEATHERPROOF • ENERGY CONTROLS • PROFESSIONAL LIGHTING • POOL & SPA • SURGE PROTECTION • CONSUMER Time Switches 24 Hr. w/Skipper, Optional Carryover T170 Series – Same features as the T100 Series plus a skipper option to omit operation on selected days. Cutout screws are inserted in the dial for days which operation is to be skipped. Provides up to 10 ON/OFF operations each day with min. ON/OFF operations of 1 hour and max. ON time of 20 hours. Includes one CUTOUT tripper (also serves as an “ON” tripper), one “OFF” tripper and three skipping screws. T170CR Series – Same features as the T170 Series Skipper models plus a min. of 16 hours carryover for maintaining preset schedules during power failures. Carryover automatically rewinds when power resumes; only one hour of rewinding time required for every two hours of power outage. 4PST models are ideal for 3-phase load control. Specifications Case – T170 Series same as T100 except as noted under Optional Enclosures. T170CR only in NEMA 3R drawn steel 9-3/8" (23.8 cm) H, 5-1/2" (14.0 cm) W, 3-5/8" (9.2 cm) D in gray finish. Hasp, with hole for lock, holds permanently attached, side-hinged door closed. Bracket plus two holes on back below switch for mounting. Separate grounding terminal. Optional Enclosures – 4 pole and 2 NO/ 2 NC models not available in standard or plastic case; only in NEMA 3R steel case. T170CR only available in steel NEMA 3R enclosure. Special Voltages and Cycles – See Time Switch Motors for available motors. Contact factory for availability of time switch with 50 cycle or other voltages. Special Voltages and Cycles – Same as T100 Series. Switch Rating – Same as T100 Series. Model # T171 T172 T173 T174 T175 T176 T1471BR* T1472BR* T1475BR* T1871BR* T171CR T173CR T174CR T1471BCR* Model # Steel NEMA 3R Case T173R T174R Switch Clock Motor Volts 60 Hz AMPS (per pole) HP Rating SPST SPST DPST DPST 1NO / 1NC** 1NO / 1NC** 4PST 4PST 4PST 2NO / 2NC*** SPST DPST DPST 4PST 125 208-277 125 208-277 125 208-277 125 208-277 480 125 125 125 208-277 125 40 40 40 40 40 40 40 40 40 40 40 40 40 40 2 5 2 5 2 5 2 5 5 2 2 2 5 2 C22.2-177 LR3730 UL916 -40°F (-40°C) to 130°F (54°C) 2.75 lbs 1.25 kg Same as T100 Series * Separate clock motor terminals for switching circuits not on line voltage. ** Can be wired as SPDT. *** Can be wired as DPDT. For additional trippers (1 ON / 1 OFF / 1 CUTOUT per pack), order No. 156T1948A. For additional skipper screws (3 skipper screws per pack), order No. 156T3085A. WEATHERPROOF • ENERGY CONTROLS • PROFESSIONAL LIGHTING • POOL & SPA • SURGE PROTECTION • CONSUMER 27 Time Switches Portable This portable cord connected time switch performs all the functions of the T100 and T170 series time switches plus it is completely portable eliminating the need for wiring. Supplied complete with 6' grounded cord set and receptacle installed. Applications (Indoor Only) • Photo Copiers • Electric Water Heaters • Ventilating Systems • Portable Lights • Air Conditioning • Motors • Signs • Fans • Pumps • Space Heaters • Poultry Foggers • Blowers Specifications Case – Drawn steel 7-3/4" (19.7 cm) High, 5" (12.7 cm) Wide, 3" (7.6 cm) Deep in gray finish. Spring hasp, with hole for lock, holds permanently attached, side hinged door closed. Three mounting holes on back plus handy box mounting holes. Knockouts – Not applicable; prewired cord and receptacle. Switch Rating – 15 Amp Resistive, 15 Amp Tungsten; 345 VA pilot duty (15 FLA), 125 VAC. G W Model # Switch Clock Motor Volts 60 Hz Amps (per pole) Skipper Wheel P171-30 SPST 125 15 Yes For additional trippers Model Series P170 (1 ON/1 OFF/1 CUTOUT per pack), order No. 156T1948A. 120V - 15A Receptacle C22.2-177 LR3730 UL917 28 3 lbs 1.36 kg -40°F (-40°C) to 130°F (54°C) WEATHERPROOF • ENERGY CONTROLS • PROFESSIONAL LIGHTING • POOL & SPA • SURGE PROTECTION • CONSUMER Time Switches 24 Hour Dial w/Skipper The T1900 Supervisor Series provides up to 96 operations (48 ON /48 OFF) every 24 hours. This series provides operations with minimum ON / OFF times of 15 minutes. Trippers slide in and out of dial for fast accurate setting. The skipper models provide for operations to be omitted on selected day(s) of the week. Model with carryover provides a minimum of 16 hours of carryover to maintain preset schedules within +/- 2% accuracy during power failures. The carryover automatically rewinds when power resumes. Only one hour is required to rewind the carryover for each two hours of power outage. Applications • Oil Well Pumps • Filters • Blowers • Poultry Feeders • Heaters • Process Equipment • Recorded Music • Dairy Equipment • Fans • Silo Unloaders • Poultry Foggers Specifications Case – Drawn steel 7-3/4" (19.7 cm) High, 5" (12.7 cm) Wide, 3" (7.6 cm) Deep in gray finish. Spring hasp, with hole for lock, holds permanently attached, side hinged door closed. Three mounting holes on back plus handy box mounting holes. Knockouts – Combination 1/2"-3/4" nominal knockouts, one on back and each side of case and two on bottom. Optional Enclosures – See Time Switch Cases for optional enclosures. Special Voltages and Cycles – See Time Switch Motors for available motors. Switch Rating – 20 Amp maximum 125, 208-277 and 480 VAC; 1/2 HP , 125 VAC; 1 HP, 250 VAC Power Input – 5 Watts maximum. Model # T1905 T1905E T1906 T1975 T1976 T1975E MODEL # STEEL NEMA 3R CASE T1975R T1976R T1975ER Switch Clock Motor Volts 60 Hz Spring Wound Carryover Amps Skipper Wheel SPDT SPDT SPDT SPDT SPDT SPDT 125 480 208-277 125 208-277 480 No No No No No No 20 20 20 20 20 20 No Yes No Yes Yes Yes C22.2-177 LR3730 UL917 2.75 lbs 1.25 kg -40°F (-40°C) to 130°F (54°C) For additional trippers (12 per pack), order No. 156T1950A. Replacement Snap Switch 133T701A. WEATHERPROOF • ENERGY CONTROLS • PROFESSIONAL LIGHTING • POOL & SPA • SURGE PROTECTION • CONSUMER 29 Time Switches Short Range Cycle Timer Short Range Cycle Timers provide repeat cycling for “ON” times. Ten combination “ON/OFF” trippers supplied with each switch. Applications • Ventilating Fans • Fogging Equipment • Process Equipment • Spraying Equipment • Poultry Feeders • Livestock Feeders • Pumps • Poultry Fans • Bulk Milk Coolers Specifications Case – Same as T100 Series. Knockouts – Same as T100 Series. Optional Enclosures – Same as T100 Series. Switch Rating – 20 Amp Resistive 125, 208-277 VAC; 1/2 HP, 125 VAC; 1 HP, 250 VAC Model # C22.2-177 LR3730 UL917 30 2.75 lbs 1.25 kg -40°F (-40°C) to 130°F (54°C) C8815 C8835 C8865 C8845 C8866 Switch Clock Motor Volts 60 Hz Dial Cycle Tripper Actuating Time Amps SPDT SPDT SPDT SPDT SPDT 125 125 125 125 250 10 Min. 30 Min. 1 Hr. 4 Hr. 1 Hr. 5 Sec. 15 Sec. 30 Sec. 120 Sec. 30 Sec. 20 20 20 20 20 Note: The life of the switch contacts is affected by the size and type of the controlled load. The expected minimum life at 20 amps (resistive) load is 100,000 cycles. Replacement Snap Switch 133T773A. For additional trippers (12 trippers per pack), order No. 156T1950A. WEATHERPROOF • ENERGY CONTROLS • PROFESSIONAL LIGHTING • POOL & SPA • SURGE PROTECTION • CONSUMER Time Switches Sprinkler/Irrigation Timer with 14-Day Skipper These irrigation timers permit 1 to 60 “ON” operations every 24 hours. This series is designed for water metering in increments of 12 minutes to 20 hours - 45 minutes for maximum conservation of precious water resources. The 14-day skipper feature permits irrigation to be omitted on selected day(s) and also provides for “every other” day operation. The “ON/OFF/AUTOMATIC” switch allows shutdown during rainy days or extended watering during dry periods without disturbing the automatic cycle set on dial. Applications • Multi-Station Hydro Indexing Valves • Irrigation Control • Greenhouses • Feeders • Lawn Sprinkling • Drip Irrigation Systems • Pumps Specifications Case – Plastic NEMA 3R case. Cases include hanging bracket plus two mounting holes on back below switch for mounting. Knockouts – Combination 1/2"-3/4" nominal knockouts, one on back and each side of case, and two on bottom. Switch Rating – T8805P101C – 15 Amps, 125 VAC, 1/2 HP, SPST. R8806P101C – 25 Amps, 208-277 VAC, 2 HP, DPST relay. R8815P101C – 25 Amps, 120 VAC, 1-1/2 HP, DPST relay. R8816P101C – 25 Amps, 208-277 VAC, 3 HP, DPST relay. T8845PV – 125 VAC, SPST, output 24 Volts - 20VA Model # T8805P101C R8806P101C R8815P101C* R8816P101C* T8845PV** Switch Motor Voltage 60 Hz Output Voltage 60 Hz AMPS (per pole) HP Rating SPST DPST DPST DPST SPST 125 208-277 120 208-277 125 –– — — –– 24 15 25 25 25 20VA 1/2 2 1-1/2 3 –– C22.2-177 LR3730 UL917 3.75 lbs 1.7 kg -40°F (-40°C) to 130°F (54°C) * Includes rain sensor input terminals- rain sensor not supplied. ** Includes 24 volt - 20 VA transformer. For additional trippers (12 per pack), order No. 156T1950A. WEATHERPROOF • ENERGY CONTROLS • PROFESSIONAL LIGHTING • POOL & SPA • SURGE PROTECTION • CONSUMER 31 Time Switches Timing Control Center, 7-Day Dial with Carryover This series provides photo control initiated / time switch terminated control. These time switches provide a different “ON/OFF” program each day of the week and a spring wound carryover. These time switches are recommended for applications where you need to turn a load “ON” at dusk and “OFF” at a preset time. The spring wound carryover provides a carryover of 16 hours minimum to maintain accurate load control even during power failure. When power resumes, the carryover automatically rewinds itself. Only 1 hour is required to rewind the carryover for each 2 hours of outage. The three models provide control of 1, 2 or 3 circuits. A light level adjustment is provided on the photo control. All models have single pole double throw switches and manual circuit by-pass switches. Unit is designed to control the contactor control circuit only. It is not recommended for direct switching of tungsten, mercury vapor or similar loads. Applications • Parking Lot Lighting • Storefront Lighting • Landscape Lighting • Stairway Lighting • Billboard Lighting • Car Lot Lighting • Entryway Lighting • Security Lighting Specifications Case – Steel in gray finish 12-1/2" (31.7 cm) high, 8-1/4" (21.0 cm) wide, 4" (10.2 cm) deep. Indoor type with toggle action drawbolt and locking feature. Four mounting holes on back. Separate grounding terminal. Knockouts – Combination 1/2"-3/4" nominal knockouts, two on back one on each side and two on bottom. Also one 1" nominal on bottom center. Optional Enclosures – None available. Contact Rating – 15 Amp, 1/2 HP, 125/250 VAC; 420 VA pilot duty; 150 Watts Tungsten, 125 VAC (May also be used with 24 volt systems if wired in accordance with National Electrical Code Regulations.) Model # Description Clock Motor Volts 60 Hz T51211BC Circuit A Circuit B Circuit A Circuit B Circuit C 120 — 120 — — T51311BC C22.2-177 LR3730 UL917 10.5 lbs 4.8 kg -40°F (-40°C) to 130°F (54°C) - Sunset, Photo Control ON - Preset Time Switch OFF Sunset, Photo Control ON - Sunrise, Photo Control OFF Sunset, Photo Control ON - Preset Time Switch OFF Sunset, Photo Control ON - Sunrise, Photo Control OFF Preset Time Switch ON - Preset Time Switch OFF All models have separate clock motor terminals for switching circuits not on line voltage. For additional trippers (7 ON / 7 Off per pack), order No. 156T2548A. See Next Generation Electronic Time Switches with Astro Feature 32 WEATHERPROOF • ENERGY CONTROLS • PROFESSIONAL LIGHTING • POOL & SPA • SURGE PROTECTION • CONSUMER Time Switches Compact, 7-Day The T2000 Series provides up to 84 (42 “ON/OFF”) operations each week. Minimum “ON/OFF” times for this series are 2 hours each providing up to 6 “ON/OFF” operations each day. Applications • Heating • Lights • Air Conditioning • Pumps • Ventilating • Motors • Defrost Control • Fans Specifications Case – Drawn steel 7-3/4" (19.7 cm) high, 5" (12.7 cm) wide, 3" (7.6 cm) deep in gray finish. Spring hasp, with hole for lock, holds permanently attached, side hinged door closed. Three mounting holes on back plus handy box mounting holes. Knockouts – Combination 1/2"-3/4" nominal knockouts, one on back and each side of case and two on bottom. Optional Enclosures – See Time Switch Cases for optional enclosures. Special Voltages and Cycles – See Time Switch Motors for available motors. Switch Rating – 20 Amp Resistive, 125 and 208-277 VAC; 1/2 HP 125 VAC; 1 HP 250 VAC Model # Switch Clock Motor Volts 60 Hz Amps T2005 T2006 SPDT SPDT 125 208-277 20 20 For additional trippers (12 per pack), order No. 156T1950A. Replacement Snap Switch 133T701A. C22.2-177 LR3730 UL917 2.75 lbs 1.25 kg -40°F (-40°C) to 130°F (54°C) WEATHERPROOF • ENERGY CONTROLS • PROFESSIONAL LIGHTING • POOL & SPA • SURGE PROTECTION • CONSUMER 33 Time Switches 7-Day Dial With & Without Carryover These time switches provide a different “ON/OFF” program each day of the week. They also provide for 4 pole single throw and 4 pole (2NO/2NC) switching. This series provides true 7-day load control with minimum ON and minimum OFF times of 3-1/2 hours. The “BC” models with carryover provide a carryover of 16 hours minimum to maintain accurate load control even during power failure. When power resumes, the carryover automatically rewinds itself. Only 1 hour is required to rewind the carryover for each 2 hours of outage. Applications • Heating • Outdoor Lighting • Ventilating Systems • Air Conditioning • Motors • Fans • Pumps • Signs • Filters • Indoor Lighting • Billboards • 3 Phase Loads Specifications C22.2-177 Models LR3730 without UL917 carryover 8 lbs 3.6 kg Models with carryover 9 lbs 4.1 kg -40°F (-40°C) to 130°F (54°C) Case – Steel in gray finish 12-1/2" (31.7 cm) high, 8-1/4" (21.0 cm) wide, 4" (10.2 cm) deep. Indoor type with toggle action drawbolt and locking feature. Four mounting holes on back. Separate grounding terminal. Knockouts – Combination 1/2"-3/4" nominal knockouts, two on back, one on each side and two on bottom. Also one 1" nominal on bottom center. Optional Enclosures – See Time Switch Cases for optional enclosures. Special Voltages and Cycles – See Time Switch Motors for available motors. Contact factory for availability of time switch with 50 cycle or other voltages. Switch Rating – Each Pole 40 amp resistive, 120-480 VAC; 40 amp tungsten, inductive or 1000 VA pilot duty, 120-277 VAC; 2 HP (24 FLA) 120 VAC; 5 HP (28 FLA) 240 VAC single phase; 7-1/2 HP (28 FLA) 208 VAC three phase; 10 HP (28 FLA) 240 VAC three phase. Carryover – Minimum time - mechanical operation: 16 hours. Carryover accuracy +/-2%. Model l# T7401B T7402B T7801B T7802B Model # Steel NEMA 3R Case Model with CarryOver T7401BR T7401BC T7402BC T7801BC T7802BC Switch Clock Motor Volts 60 Hz Amps (per pole) 4PST 4PST 2NO/2NC 2NO/2NC 125 208-277 125 208-277 40 40 40 40 * All models (B or BC suffix) have separate clock motor terminals for switching circuits not on line voltage. For additional trippers (7 ON / 7 OFF per pack), order No. 156T2548A. 34 WEATHERPROOF • ENERGY CONTROLS • PROFESSIONAL LIGHTING • POOL & SPA • SURGE PROTECTION • CONSUMER Time Switches Astro Dial With Skipper & Carryover This time switch self adjusts for seasonal changes. The astronomic dial automatically adjusts itself as the days grow shorter or longer. A skipper provides lighting control to be omitted on selected day(s) of the week. The carryover is designed to maintain preset schedule during power outages for a minimum of 16 hours. Only 1 hour is required to rewind the carryover for each 2 hours of outage. The 3PST switch configuration provides for control of 3-phase lighting. Three skipper screws are furnished. Lighting Applications • Parking Lots • Entryways • Landscape Lights • Security • Stairways • Storefronts • Billboards • Car Lots Specifications Case – NEMA 3R drawn steel 11-1/2" (29.2 cm) high, 8-1/4" (20.9 cm) wide, 4-1/2" (11.4 cm) deep in gray finish. Hasp, with hole for lock, holds permanently attached, side hinged door closed. Mounting bracket plus two holes below switch on back for mounting. Separate grounding terminal. Knockouts – Combination 1/2"-3/4" nominal knockouts, one on back and each side of case and two on bottom. Optional Enclosures – None. Switch Rating – Each pole: 40 amp tungsten up to 277 VAC; 1 HP, 120 VAC; 690 VA pilot duty. Model # Switch V45471CR* V45472CR* V45471R V45472R 3PST 3PST 3PST 3PST Clock Motor Volts 60 Hz Amps 125 208-277 125 208-277 40 40 40 40 # Indicate City and State nearest installation when ordering. * Includes spring wound carryover. For additional skipper screws (3 skipper screws per pack), order No. 156T1957A. UL917 E10694 C22.2-177 Models LR3730 V45471C R& V45472C R 9 lbs 4.1 kg Other Models 5 lbs 2.3 kg -40°F (-40°C) to 130°F (54°C) For Electronic Time Switches which offer Astro Feature please see pages 42-44 WEATHERPROOF • ENERGY CONTROLS • PROFESSIONAL LIGHTING • POOL & SPA • SURGE PROTECTION • CONSUMER 35 Time Switches Water Heater Time Switches The WH40 provides a convenient external override switch. Utilities in many areas of the country offer two electric rates for residential or commercial customers. One rate has the regular daytime electrical rate, the other is “off peak” rate. The off peak rate provides customers with “lower-priced” electricity during the nighttime and weekend periods. These time switches allow the customer to shift electricity use into these off-peak time periods in an attempt to save utility costs. Applications Water Heater Control for: • Residential • Commercial • Industrial • Institutional / Schools • Military Facilities Specifications The "LITTLE GRAY BOX"® Case – Drawn steel 7-3/4" (19.7 cm) High, 5" (12.7 cm) Wide, 3" (7.6 cm) Deep in gray finish. Spring hasp, with hole for lock, holds permanently attached, side hinged door closed. Three mounting holes on back plus handy box mounting holes. Knockouts – Combination 1/2"-3/4" nominal knockouts, one on back and each side of case and two on bottom. Special Voltages and Cycles – See Time Switch Motors for available motors. Switch Rating – 40 Amp Resistive, Inductive or Tungsten 120-277 VAC; 1000 VA pilot duty 120-277 VAC; 2 HP (24 FLA) 125 VAC; 5 HP (28 FLA) 240 VAC. Model # Switch Clock Supply Volts 60 Hz Watts External Switch Amps/Pole T104-20 WH40 DPST DPST 208-240 250 10000 10000 No Yes 40 40 For additional trippers (1 ON / 1 OFF per pack), order No. 156T1978A. C22.2-177 LR3730 UL917 36 2.75 lbs 1.25 kg -40°F (-40°C) to 130°F (54°C) WEATHERPROOF • ENERGY CONTROLS • PROFESSIONAL LIGHTING • POOL & SPA • SURGE PROTECTION • CONSUMER Time Switches Electronic Water Heater Timers These time switches provide automatic control for electric water heaters. They provide to-the-minute accuracy in programming and time keeping. The time switches can be programmed for repeat daily scheduling, 5-day working week scheduling, weekend scheduling or any individual day scheduling. Timers can be scheduled for operation during the lowest time-of-day rates or to switch off the electric heater during period of utilities peak power usage. The time switch can be set to operate for up to 6 on/off operations daily for a maximum of 42 on/off operations weekly. Both models provide a convenient external override switch and LED load indicator for ease in scheduling hot water as required for extra hot water demands. The timers include a “AA” alkaline battery carryover which protects both time keeping and program information for a minimum of 3 years. Applications Water Heater Control for: • Residential • Military Facilities • Institutional • Schools • Industrial • Commercial Specifications Case – Drawn steel 7-3/4" (19.7 cm) H x 5" (12.7 cm) W x 3" (7.6 cm) D in gray finish. Spring hasp, with hole for lock, holds permanently attached, side hinged door closed. Three mounting holes on back plus handy box mounting holes. Knockouts – Combination 1/2"–3/4" nominal knockouts, one on back and each side of case and two on bottom. Switch Rating – 30 Amp Resistive or Inductive 120-240 VAC; 1 HP, 120 VAC; 1-1/2 HP, 240 VAC; 5 Amps Tungsten, 120/240 VAC. Model # Switch Clock Supply Volts 50/60 Hz Watts External Switch Amps/Pole EH10 EH40 SPST DPST 120 240 3600 7200 Yes Yes 30 30 With Manual External Override and Load Indicator 50/60 Hz Operation UL916 E76987 C22.2-177 LR3730 2.75 lbs 1.25 kg -4°F (-20°C) to 122°F (50°C) WEATHERPROOF • ENERGY CONTROLS • PROFESSIONAL LIGHTING • POOL & SPA • SURGE PROTECTION • CONSUMER 37 Time Switch Cases A. Plastic Case Ends rusting problems forever. Made of heavy-duty industrial grade plastic, Intermatic’s rainproof all plastic case is perfect for applications where high humidity and/or dust can be a problem. Developed for use with pool and spa equipment, the non-corroding plastic case is useful for applications in other high moisture areas such as car washes, industrial water spray areas, etc; NEMA 3R case. A. 2T2500GA A hasp with a hole for lock holds the side-hinged door closed. A bracket plus two holes below the switch on the back are for mounting. Has five combination 1/2 - 3/4" nominal knockouts, one on back and each side of case, two on bottom. Plastic Case NEMA 3R Model Number Description Weight 2T2500GA* 2T2502GA* Indoor / Outdoor Plastic Case – 9-3/8" x 5-1/2" x 3-3/4" Beige Indoor / Outdoor Plastic Case – 9-3/8" x 5-1/2" x 3-3/4" 1.3 lbs 1.3 lbs * Available for SERIES T100, T170, T180, T1100, T1200, T1400, T1900, T2000, C8800, ET100C, ET170C,ET700C and models EH10, EH40, ET279C ET70115, ET70215, and ET8000 series B. Standard Case B. 2T2040GA Standard Case NEMA 1 Drawn steel with gray powder coat paint finish. Spring hasp (with hole for seal or lock) holds permanently attached hinged door closed. Has combination 1/2" - 3/4" nominal knockouts, one on back and on each side, and two on bottom. (Except “P” Series switches which are equipped with cord-connection and receptacle.) Convenient mounting holes. NEMA Type 1. Model Number Description Weight 2T2040GA* 2T2292GA** Standard Indoor Case – 7 3/4" x 5" x 3" Indoor Case – 12-1/2" x 8-1/4" x 3-7/8" 1.4 lbs 7.0 lbs * Available for SERIES T100, T170, T180, T1100, T1200, T1400, T1900, T2000, C8800, ET100C, ET170C,ET700C and models EH10, EH40, ET279C ET70115, ET70215, and ET8000 series ** Available for SERIES T7400B, T7800B, T7400BC and T7800BC. C. Indoor-Outdoor Case C. 2T511GA Steel Indoor/Outdoor Case NEMA 3R For protecting time switch from rain, sleet, snow and ice. Drawn steel with gray or beige powder coat paint .036" construction with side-hinged door. Hasp provided for lock. Has combination 1/2-3/4" nominal knockouts, one on back and each side of case, and two on bottom. Separate grounding terminal. Convenient mounting holes. NEMA 3R. Model Number Description Weight 2T511GA* 2T2485GA* 2T2331GA** 2T2293GA*** 2T1985GR**** Standard Indoor/Outdoor Case – 9-3/8" x 5-1/2" x 3-5/8" Beige Standard Indoor/Outdoor Case – 9-3/8" x 5-1/2" x 3-5/8" Indoor/Outdoor Case – 9-3/8" x 5-1/2" x 3-5/8" Indoor/Outdoor Case – 12-1/2" x 8-1/4" x 3-7/8" Indoor/Outdoor Case – 9-3/8" x 5-1/2" x 3-5/8" 2.5 lbs 2.5 lbs 2.5 lbs 2.5 lbs 2.5 lbs * ** *** **** D. TS100RS Steel Indoor/Outdoor Case NEMA 3R D. Stainless Steel Indoor-Outdoor Case Model Number Description Weight TS100RS Stainless Steel Indoor-Outdoor Case – 9 7/8" x 6 1/2" x 3 1/5" 3.5 lbs * UL & CSA apply to all enclosures shown. UL917 E10694 38 Available for SERIES T100, T170, T180, T1100, T1200, T1400, T1900, T2000, C8800, ET100C, ET170C,ET700C and models EH10, EH40, ET279C ET70115, ET70215, and ET8000 series Available for SERIES T100CR, T170CR, T1400BR, T1400BCR, T1800BR and T1800BCR. Available for SERIES T7400B, T7800B, T7400BC and T7800BC. Available for SERIES LS7000 only. Available for SERIES T100, T170, T1400, T1900, T2000, C8800, ET100C, ET170C, ET700C, EH40, ET279C, ET70115, ET70215 and ET8000. C22.2-177 LR3730 WEATHERPROOF • ENERGY CONTROLS • PROFESSIONAL LIGHTING • POOL & SPA • SURGE PROTECTION • CONSUMER Time Switch Cases E. 2-in-1 Raintight Case and Panel 22T713 (Brackets Only) For use where 2 time switches are to be mounted side by side. Heavy-duty spot-welded raintight construction with powder coat paint. Hasp (with hole for lock) holds permanently attached hinged door closed. Combination 1/2" - 3/4" nominal knockouts conveniently located (two on back, five on bottom and one on each side). Top mounting brackets plus two holes below switch level on back of case. Model Number Description Weight T10000R (replaces 2T2089GA)* T30000R* T40000R* 2-in-1 Indoor/Outdoor Case – 10-1/2" x 10-1/2" x 4" Indoor/Outdoor Panel – 16-3/4" x 10-1/2" x 4-1/4" Indoor/Outdoor Panel – 20-3/4" x 12-3/4" x 4-1/4" 6.5 lbs 11.0 lbs 17.0 lbs * Available for SERIES T100, T170, T180, T1900, T2000 and C8800. NOT FOR T1400/T1800/T1900 MODELS WITH BCR SUFFIX. F. Flushmount Case E. T10000R For concealing mechanism in wall and giving a finished, flushed appearance. Heavy-duty, .063" formed steel construction with hinged door. Gray finish with powder coat paint. Combination 1/2" - 3/4" nominal knockouts one each side, and two on bottom, plus one 1" knockout on top and bottom. Convenient mounting holes. With or without key lock. Cutout 9-1/8" x 6" x 4-1/8" deep; flange 11" x 8" Model Number Description Weight 2T308A* 2T2365GA** 6ET1398GA 2T2366GA Standard Flushmount w/Lock Flushmount Case w/Lock Flush Cover for ET70415CR and ET70415CR24 Flush Cover for ET70415CR and ET70415CR24 with lock 6.5 lbs 7.0 lbs 2.5 lbs 2.5 lbs 2-in-1 Raintight Case * Available for SERIES T100, T170, T180, T1900, T2000 and C8800. NOT FOR T1400/T1800/T1900 MODELS WITH BCR SUFFIX. ** Available for SERIES ET100C, ET170C, ET700C and models EH10, EH40, ET279C, ET7115C, ET7215C, ET70215C and ET70115C. G. Mounting Brackets Heavy gauge steel mounting bracket mounts to a standard symmetrical rail TS35 according to DIN46277 and EN50022. Ideal for panel mounting of mechanical or electronic time switch controls, along side of other DIN rail mountable electrical devices. This snap-in type bracket accepts a wide range of Intermatic time switches including most T100, T170, T180, T1900, T2000, C8800, ET100, ET170, ET700 and ET70000 time switches. Model Number Description Weight 22T535GR 22T338GR Din Rail Bracket – 6" x 5" x 2" Surface Mount Snap-in Bracket – 6" x 5" x 2" 1.0 lbs 1.0 lbs F. 2T2365GA Flushmount Case Surface Mount Bracket G. 22T338GR UL917 E10694 C22.2-177 LR3730 Din Rail Bracket 22T535GR UL & CSA apply to all enclosures shown. WEATHERPROOF • ENERGY CONTROLS • PROFESSIONAL LIGHTING • POOL & SPA • SURGE PROTECTION • CONSUMER 39 Electronic Energy Controls 24-Hour Electronic Time Switches ET100 Series 24-Hour Time Switch (Same Operation Each Day) These time switches provide the same dependable and uncomplicated performance as the T101 mechanical time switch...plus to-the-minute programming for accurate load control and reduced energy costs. Up to 8 set points or events (4 ON/4 OFF) can be preset to automatically repeat on a daily basis. The program can be overridden at any time by placing the selector switch in the Manual position. Two industrial grade “AA” Alkaline batteries provide 3 years minimum program and timing protection. Specifications Case – NEMA 1 – Drawn steel 7-3/4" (19.7 cm) High, 5" (12.7 cm) Wide, 3" (7.6 cm) Deep in gray finish. Note: The electronic mechanism snaps into the standard Intermatic time switch case, replacing mechanical mechanisms, if desired. Knockouts – Combination 1/2"-3/4" nominal knockouts, one on back and each side of case and two on bottom. Optional Enclosures – See Time Switch Cases for optional enclosures. Special Voltages and Cycles – ALL models 50 or 60 Hz. Switch Rating – Except model ET100C. 30 Amp Inductive/Resistive, 24 / 120 / 240 / 277 VAC 60 Hz; 20 Amp Resistive, 28 VDC; 1 HP 120 VAC 60 Hz; 2 HP 240 VAC 60 Hz; 5 Amp Tungsten, 120 / 240 / VAC 60 Hz; 20 Amp ballast,120-277 VAC 60 Hz. ET100C same ratings for 120 Volt loads only. Models ET105C normally closed contact ratings: 10A Resistive/General purpose, 12 - 277VAC; 10A Resistive/General purpose, 28VDC; 3A Ballast, 120 - 277VAC; 1/4 HP, 120 VAC; 1/2 HP, 240 VAC; 30 LRA; 12 FLA; 275 VA pilot duty, 120 - 240 VAC Carry-over – Field replaceable “AA” batteries maintain program and accurate time keeping for 3 years minimum. Up front replacement does not require removal of mechanism or field wiring. Wiring Terminals – #18 to #10 AWG wire. Minimum ON/OFF Times – 1 minute. Maximum ON/OFF Times – 23 hours 59 minutes. Applications: • Schools • Offices • Airports • Stores • Hotels • Restaurants • Parks • Apartments For Controlling: • Water Heaters • Parking Lot Lighting • Commercial Ovens • Interior Lighting • Air Conditioners • Fans/Blowers/Pumps • Livestock Feeders • Poultry Equipment • Process Equipment UL917 C22.2-177 LR3730 Engineering Specification 24 Hour Electronic Time Switch The time switch shall be a solid state electronic control capable of permitting 8 ON/OFF set points to be distributed on a daily schedule. The time and set points shall be programmable to the nearest minute with a minimum ON duration of 1 minute and a maximum ON duration of 23 hours and 59 minutes. The timer shall have a digital LCD readout to show time-of-day using 12 hour AM/PM indicator. The time switch shall provide a manual override control for both temporary or permanent override. Time switch shall operate over a temperature range of -40°F (40°C) to 155°F (68°C). An industrial grade AA alkaline battery shall protect program information and time-of-day for a minimum of 3 years. Switch configuration to be __________ (SPST) or (DPST) with a UL listed rating of: 30 amp Inductive/Resistive, 24/120/240 Volts AC, 60 Hz; 20 amps Resistive, 28 VDC; 1 HP, 120 Volts AC, 60 Hz; 2 HP, 240 Volts AC, 60 Hz; 5 amps Tungsten, 120/240 Volts AC, 60 Hz; 20 amps Ballast, 120-277 Volts AC, 60 Hz. The time switch shall be powered by a __________ (120 volt), (120-277 volts) 50/60 Hz source. The time switch shall be enclosed in a lockable steel NEMA 1 rated enclosure. The time switch shall be UL listed under UL category 916 Energy Management Equipment and shall be INTERMATIC Model __________. 2.5 lbs 1.1 kg -40°F (-40°C) to 155°F (68°C) Model# ET100C ET100CM1 ET101C ET102C ET103C ET104C ET104CP2 ET105C Circuits Switch Clock Voltage Amp Rating HP Rating Enclosure 1 1 1 1 1 1 1 1 SPST SPST SPST SPST DPST DPST DPST SPDT 120 120 120 120/208/240/277 120 120/208/240/277 120/208/240/277 120 30 30 30 30 30 30 30 10/30 1HP 1HP 1HP / 2HP 1HP / 2HP 1HP / 2HP 1HP / 2HP 1HP / 2HP 1HP / 2HP NEMA1 Mech. NEMA1 NEMA1 NEMA1 NEMA1 NEMA3R NEMA1 1 Mechanism only no case. NEMA 3R UV resistant polycarbonate plastic case. 2 40 WEATHERPROOF • ENERGY CONTROLS • PROFESSIONAL LIGHTING • POOL & SPA • SURGE PROTECTION • CONSUMER Electronic Energy Controls 7-Day Electronic Time Switches ET170 Series 7-Day Time Switch (Permits Different Operation Each Day) These electronic time switches provide to-the-minute programming for accurate load control and reduced energy costs. Up to 20 set points or events (10 ON/10 OFF or any combination) can be preset to automatically repeat on a weekly or daily basis. The program can be overridden at any time by placing the selector switch in the Manual position. These time switches provide for true 7-day load control with up to 140 operations (70 ON/70 OFF or any combination) each week. Model ET279C provides 20 operations or momentary contact closures of 1 to 8 seconds (ten each or any combination) for two independent circuits. Specifications Case – NEMA 1 – Drawn steel 7-3/4" (19.7 cm) High, 5" (12.7 cm) Wide, 3" (7.6 cm) Deep in gray finish. NEMA 3R – Drawn steel 9-3/8" (23.8 cm) high, 5-1/2" (14.0 cm) wide, 3-5/8" (9.0 cm) deep in gray finish. Both types include permanently attached side hinged door with lockable hasp. Mounting holes and/or mounting bracket included. Separate grounding terminal. Note: The electronic mechanism snaps into the standard Intermatic time switch case, replacing mechanical mechanisms, if desired. Knockouts – Combination 1/2"-3/4" nominal knockouts, one on back and each side of case and two on bottom. Optional Enclosures – See Time Switch Cases for optional enclosures. Special Voltages and Cycles – ALL models 50 or 60 Hz. Switch Rating – 30 Amp Inductive/Resistive, 24 / 120 / 240 / 277 VAC 60 Hz; 20 Amp Resistive, 28 VDC; 1 HP 120 VAC 60 Hz; 2 HP 240 VAC 60 Hz; 5 Amp Tungsten, 120 / 240 / VAC 60 Hz; 20 Amp ballast, 120-277 VAC 60 Hz. ET100C same ratings for 120 Volt loads only. Model ET175C normally closed contact ratings: 10A Resistive/General purpose, 12 - 277VAC; 10A Resistive/General purpose, 28VDC; 3A Ballast, 120 - 277VAC; 1/4 HP, 120 VAC; 1/2 HP, 240 VAC; 30 LRA; 12 FLA; 275 VA pilot duty, 120 - 240 VAC Carry-over – Field replaceable “AA” batteries maintain program and accurate time keeping for 3 years minimum. Up front replacement does not require removal of mechanism or field wiring. Wiring Terminals – #18 to #10 AWG wire. Minimum ON/OFF Times – 1 minute. Maximum ON/OFF Times – 6 days 23 hours 59 minutes. Engineering Specification 7 Day 30 Amp Electronic Time Switches The time switch shall be a solid state electronic control capable of permitting 20 ON/OFF set points to be distributed on independent daily schedules through a 7-day time period. The time switch shall include a 7-day repeat feature for simplifying programming of identical set points. The time and set points shall be programmable to the nearest minute with a minimum ON duration of 1 minute and a maximum ON duration of 6 days, 23 hours, 59 minutes. The timer shall have a digital LCD readout to show day of week and time-of-day using 12 hour AM/PM indicator. The time switch shall provide a manual override control for both temporary or permanent override. Time switch shall operate over a temperature range of -40°F (-40°C) to 155°F (68°C). An industrial grade AA alkaline battery shall protect program information and time-of-day for a minimum of 3 years. Switch configuration to be __________ (SPST) or (DPST) with a UL listed rating of: 30 amp Inductive/Resistive, 24/120/240 Volts AC, 60 Hz; 20 amps Resistive, 28 VDC; 1 HP, 120 Volts AC, 60 Hz; 2 HP, 240 Volts AC, 60 Hz; 5 amps Tungsten, 120/240 Volts AC, 60 Hz; 20 amps Ballast, 120-277 Volts AC, 60 Hz. The time switch shall be powered by a __________ (120 volt), (120-277 volts) 50/60 Hz source. The time switch shall be enclosed in a lockable steel NEMA 1 rated enclosure. The time switch shall be UL listed under UL category 916 Energy Management Equipment and shall be INTERMATIC Model __________. Model# Circuits Switch Clock Voltage Amp Rating HP Rating Enclosure ET171C ET171CR1 ET173C ET174C ET175C ET279C2,3 1 1 1 1 1 2 SPST SPST DPST DPST SPDT SPST 120 120 120 240 120 120 30 30 30 30 10/30 30 1HP / 2HP 1HP / 2HP 1HP / 2HP 1HP / 2HP 1HP / 2HP 1HP / 2HP NEMA1 NEMA3R NEMA1 NEMA1 NEMA1 NEMA1 ENERGY CODE UPDATE In 2002 the Department of Energy (DOE) settled on ASHRAE 90.1-1999 as the commercial building standard for state building energy codes acting on its authority under the Energy Conservation & Production Act. The deadline set by the DOE for state compliance was July 15, 2004 by which each state must enact energy codes at least as strict as the standard or provide justification for non-compliance. Intermatic offers a variety of products to assist the specifying engineer and contractor with meeting the ASHRAE 90.1-1999 requirements including the Next Generation series of programmable time switches, spring wound and electronic in-wall timers, and a full line of photo controls. UL917 C22.2-177 LR3730 2.5 lbs 1.1 kg -40°F (-40°C) to 155°F (68°C) 1 NEMA 3R drawn steel enclosure. User selectable contacts independent 2xSPST, simultaneous DPST, or pulsed for mechanically held contactor operation. Complies with California Title 24 requirements for multi-level outdoor lighting control. 2 3 WEATHERPROOF • ENERGY CONTROLS • PROFESSIONAL LIGHTING • POOL & SPA • SURGE PROTECTION • CONSUMER 41 Electronic Energy Controls 7-Day Electronic Astronomic Time Switches ET8000 Series 7-Day Astronomic Time Switch (Tracks Sunrise & Sunset) Intermatic’s Electronic Astronomic 7-Day Time Switch automatically switches loads according to a preset weekly schedule with to-the-minute accuracy. The astronomic feature provides sunset ON and sunrise OFF settings to eliminate the need for separate photo control devices. The independent 7-day programming provides complete flexibility for applications where load switching differs each day of the week. Astronomic programming can be combined with independent programs to provide a sunset ON and timed OFF program. Specifications Case – NEMA 1 – Drawn steel 7-3/4" (19.7 cm) High, 5" (12.7 cm) Wide, 3" (7.6 cm) Deep in gray finish. NEMA 3R – Drawn steel 9-3/8" (23.8 cm) high, 5-1/2" (14.0 cm) wide, 3-5/8" (9.0 cm) deep in gray finish. Both types include permanently attached side hinged door with lockable hasp. Mounting holes and/or mounting bracket included. Separate grounding terminal. Note: The electronic mechanism snaps into the standard Intermatic time switch case, replacing mechanical mechanisms, if desired. Knockouts – Combination 1/2"-3/4" nominal knockouts, one on back and each side of case and two on bottom. Optional Enclosures – See Time Switch Cases for optional enclosures. Special Voltages and Cycles – ALL models 50 or 60 Hz. Switch Rating – 30 Amp Inductive/Resistive, 24 / 120 / 240 / 277 VAC 60 Hz; 20 Amp Resistive, 28 VDC; 1 HP 120 VAC 60 Hz; 2 HP 240 VAC 60 Hz; 5 Amp Tungsten, 120 / 240 / VAC 60 Hz; 20 Amp ballast, 120-277 VAC 60 Hz. Model ET8115C normally closed contact ratings: 10A Resistive/General purpose, 12 - 277VAC; 10A Resistive/General purpose, 28VDC; 3A Ballast, 120 - 277VAC; 1/4 HP, 120 VAC; 1/2 HP, 240 VAC; 30 LRA; 12 FLA; 275 VA pilot duty, 120 - 240 VAC Carry-over – Field replaceable “AAA” batteries maintain program and accurate time keeping for 3 years minimum. Up front replacement does not require removal of mechanism or field wiring. Wiring Terminals – #18 to #10 AWG wire. Minimum ON/OFF Times – 1 minute. Maximum ON/OFF Times – 6 days 23 hours 59 minutes. Applications: • Schools • Offices • Airports • Stores • Hotels • Restaurants • Parks • Apartments For Controlling: • Water Heaters • Parking Lot Lighting • Commercial Ovens • Interior Lighting • Air Conditioners • Fans/Blowers/Pumps • Livestock Feeders • Poultry Equipment • Process Equipment UL917 C22.2-177 LR3730 Engineering Specification 2.5 lbs 1.1 kg -40°F (-40°C) to 155°F (68°C) 7 Day 30 Amp Electronic Time Switches The time switch shall be a solid state electronic control capable of permitting 14 ON, 14 OFF set points to be distributed on independent daily schedules through a 7-day time period with 1 astro ON and 1 astro OFF set point per controlled channel . The time switch shall include a 7-day repeat feature for simplifying programming of identical set points. The time and set points shall be programmable to the nearest minute with a minimum ON duration of 1 minute and a maximum ON duration of 6 days, 23 hours, 59 minutes. The timer shall have a digital LCD readout to show day of week, time-of-day, and date using 12 hour AM/PM indicator. The time switch shall provide a manual override control for both temporary or permanent override. Time switch shall operate over a temperature range of -40°F (-40°C) to 155°F (68°C). An industrial grade AAA alkaline battery shall protect program information and time-of-day for a minimum of 3 years. Switch configuration to be __________ (SPST) or (DPST) with a UL listed rating of: 30 amp Inductive/Resistive, 24/120/240 Volts AC, 60 Hz; 20 amps Resistive, 28 VDC; 1 HP, 120 Volts AC, 60 Hz; 2 HP, 240 Volts AC, 60 Hz; 5 amps Tungsten, 120/240 Volts AC, 60 Hz; 20 amps Ballast, 120-277 Volts AC, 60 Hz The time switch shall be powered by a __________ (120 volt), (120-277 volts) 50/60 Hz source. The time switch shall be enclosed in a lockable steel NEMA 1 rated enclosure. The time switch shall be UL listed under UL category 916 Energy Management Equipment and shall be INTERMATIC Model __________. Model# CPD82 NEMA 3R with clear cover 42 ET8015C ET8015CPD82 ET8015CR1 ET8115C ET8115CPD82 ET8115CR1 ET8215C2,3 ET8215CPD822,3 ET8215CR1,2,3 Circuits Switch Clock Voltage Amp Rating HP Rating Enclosure 1 1 1 1 1 1 2 2 2 SPST SPST SPST SPDT SPDT SPDT SPST SPST SPST 120/208/240/277 120/208/240/277 120/208/240/277 120/208/240/277 120/208/240/277 120/208/240/277 120/208/240/277 120/208/240/277 120/208/240/277 30 30 30 10/30 10/30 10/30 30 30 30 1HP / 2HP 1HP / 2HP 1HP / 2HP 1HP / 2HP 1HP / 2HP 1HP / 2HP 1HP / 2HP 1HP / 2HP 1HP / 2HP NEMA1 NEMA3R NEMA3R NEMA1 NEMA3R NEMA3R NEMA1 NEMA3R NEMA3R 1 NEMA 3R drawn steel enclosure. User selectable contacts independent 2xSPST, simultaneous DPST, or pulsed for mechanically held contactor operation. 3 Complies with California Title 24 requirements for multi-level outdoor lighting control. 2 WEATHERPROOF • ENERGY CONTROLS • PROFESSIONAL LIGHTING • POOL & SPA • SURGE PROTECTION • CONSUMER Electronic Energy Controls 365-Day Electronic Astronomic Time Switches ET70000 Series 365-Day Time Switch (1 & 2 Circuit Models) These electronic time switches provide to-the-minute programming for 7-day or full year load control. Features: 12/24 Hr clock format, 1,000 + ON/OFF events, 99 holiday schedules, and auto daylight savings time adjustment. Flexible load control is enhanced by Astro, Variable Pulse, and Interval options as required for outdoor lighting control, bell ringing and after hours temporary override respectively. Non-volatile memory maintains all programmed switching times for the life of the time switch. A factory installed field replaceable lithium battery maintains accurate time keeping and calender information for a minimum of 8 years. Specifications Case – NEMA 1 – Drawn steel 7-3/4" (19.7 cm) High, 5" (12.7 cm) Wide, 3" (7.6 cm) Deep in gray finish. NEMA 3R – Drawn steel 9-3/8" (23.8 cm) high, 5-1/2" (14.0 cm) wide, 3-5/8" (9.0 cm) deep in gray finish. Both types include permanently attached side hinged door with lockable hasp. Mounting holes and/or mounting bracket included. Separate grounding terminal. Note: The electronic mechanism snaps into the standard Intermatic time switch case, replacing mechanical mechanisms, if desired. ON/OFF Events – 1,000+ Events. Knockouts – Combination 1/2"-3/4" nominal knockouts, one on back and each side of case and two on bottom. Optional Enclosures –See Time Switch Cases for optional enclosures. Special Voltages and Cycles – Line voltage models 50 or 60 Hz; Low voltage models 60 Hz 24 Volts. Switch Rating – Each Pole; 20 amp resistive/general purpose, 12–277 Volts AC; 20 amp resistive/general purpose, 28 Volts DC; 20 amp ballast, 120–277 VAC; 1 HP, 120 VAC 60 Hz; 98 LRA; 22 FLA; 2 HP, 240 VAC 60 Hz; 80 LRA; 30 FLA; 5 amp tungsten, 120–240 VAC; 470 VA pilot duty, 12–240 VAC; TV-5, 120–240 VAC Carry-over – Non-volatile memory requires no backup. Time keeping and calender data maintained within 0.01% accuracy for minimum of 8 years with one factory installed, field replaceable lithium coin cell. Wiring Terminals – #18 to #10 AWG wire. Minimum ON/OFF Times – 1 minute. Maximum ON/OFF Times – 6 days 23 hours 59 minutes. Engineering Specification 365 Day 1, 2, & 4 Circuit Electronic Astronomic Time Switches The time switch shall be a solid state electronic control capable of permitting 1000 ON/OFF set points to be distributed on independent daily schedules through a 7-day time period and across 99 separate holiday schedules. The time switch shall include a 7-day repeat feature for simplifying programming of identical set points. The time and set points shall be programmable to the nearest minute with a minimum ON duration of 1 minute and a maximum ON duration of 6 days, 23 hours, 59 minutes. The timer shall have a digital LED readout to show day-of-week and time-of-day using 12/24 hour time format. The time switch shall provide a manual override control for both temporary or permanent override. Time switch shall operate over a temperature range of -40°F (-40°C) to 155°F (68°C). A non-volatile memory shall maintain all program data for the life of the time switch without the need for battery backup. The time switch shall include a factory installed lithium battery backup which shall maintain clock time and calendar data for 8 years minimum. Switch configuration to be SPDT for each circuit with a UL 916 Energy Management Equipment listed rating of: Normally Open Contacts Each Pole; 20 amp resistive/general purpose, 12-277 Volts AC; 20 amp resistive/general purpose, 28 Volts DC; 20 amp ballast, 120-277 VAC; 1 HP, 120 VAC 60 Hz; 98 LRA; 22 FLA; 2 HP, 240 VAC 60 Hz; 80 LRA; 30 FLA; 5 amp tungsten, 120-240 VAC; 470 VA pilot duty, 12-240 VAC; TV-5, 120-240 VAC Normally Closed Contacts 10 Amp Resistive/general purpose, 12-277 VAC; 10 Amp Resistive/general purpose, 28 Volts DC; 3 Amp ballast, 120-277 VAC; 1/4 HP, 120 VAC 60 Hz; 1/2 HP, 240 VAC 60 Hz; 30 LRA; 12 FLA; 275 VA pilot duty, 12-240 VAC. The time switch shall be enclosed in a lockable steel _____ (NEMA 1) (NEMA 3R) enclosure. The time switch shall be powered by a __________ (user selectable 120, 208, 240 or 277 VAC 50 or 60 Hz) (24 VAC 60 Hz) source. The time switch shall be INTERMATIC Model ________________ (ET70115C, ET70115CR or ET70115CR24 1-circuit) ASHRAE 90.1-1999 Section 9.2.1.3 Exterior Lighting Control Lighting for all exterior applications not exempted in 9.1 and 9.3.2 shall be controlled by a photosensor or astronomical time switch that is capable of automatically turning off the exterior lighting when sufficient daylight is available or the lighting is not required. The Intermatic Next Generation series provides an easy to program time-of-day lighting control. The multiple zones, as required in the standard, are available in 1, 2, 4, 8, or 16 zones of control. Space control for each zone can be provided by a remote timed override. Each override can be set for the code required maximum of four hours. (ET70215C, ET70215CR or ET70215CR24 2-circuits) Model# ET70115C ET70115CR1 ET70115CR241 ET70215C2,3 ET70215CR1,2,3 ET70215CR241,2,3 Circuits Switch Clock Voltage Amp Rating HP Rating Enclosure 1 1 1 2 2 2 SPDT SPDT SPDT SPDT SPDT SPDT 120/208/240/277 120/208/240/277 24 120/208/240/277 120/208/240/277 24 20 20 20 20 20 20 1HP / 2HP 1HP / 2HP 1HP / 2HP 1HP / 2HP 1HP / 2HP 1HP / 2HP NEMA1 NEMA3R NEMA3R NEMA1 NEMA3R NEMA3R UL916 E76987 UL917 C22.2-177 LR3730 2.5 lbs 1.1 kg -40°F (-40°C) to 155°F (68°C) 1 NEMA 3R drawn steel enclosure. User selectable contacts independent 2xSPST, simultaneous DPST, or pulsed for mechanically held contactor operation. Complies with California Title 24 for multi-level outdoor lighting control. 2 3 WEATHERPROOF • ENERGY CONTROLS • PROFESSIONAL LIGHTING • POOL & SPA • SURGE PROTECTION • CONSUMER 43 Electronic Energy Controls 365-Day Electronic Astronomic Time Switches ET70000 Series 365-Day Time Switch (4, 8, & 16 Circuit Models) These electronic time switches provide to-the-minute programming for 7-day or full year load control. Features: 12/24 Hr Clock Format, 4,000+ ON/OFF Events (8 & 16 circuit models only), 99 Holiday Schedules, and Auto Daylight Savings Time Adjustment. Flexible load control is enhanced by Astro, Variable Pulse, and Interval options as required for outdoor lighting control, bell ringing and after hours temporary override respectively. Non-volatile memory maintains all programmed switching times for the life of the time switch. A factory installed field replaceable lithium battery maintains accurate time keeping and calender information for a minimum of 8 years. Specifications Case – 4-Circuit NEMA 3R – Heavy duty .047" 18 gauge steel in gray finish; 12-1/2" (31.7 cm) High, 8-1/4" (21.0 cm) Wide, 4" (10.2 cm) Deep. 8-Circuit NEMA 3R - Heavy duty .048" steel in gray finish; 10-3/4" (27.3 cm) High, 11-1/2" (29.2 cm) Wide, 4-3/4" (12.1 cm) deep with lockable hasp. 16-Circuit NEMA 3R Heavy duty .060" steel in gray finish; 20-5/8" (52.4 cm) High, 13-1/4" (33.7 cm) Wide, 5-1/8" (13.0 cm) Deep with lockable hasp. ON/OFF Events – 4-Circuit - 1,000+ Events; 8 & 16-Circuit - 4,000+ Events. Special Voltages and Cycles – Line voltage models 50 or 60 Hz; Low voltage models 60 Hz 24 Volts. Switch Rating – Each Pole; 20 amp resistive/general purpose, 12–277 Volts AC; 20 amp resistive/general purpose, 28 Volts DC; 20 amp ballast, 120–277 VAC; 1 HP, 120 VAC 60 Hz; 98 LRA; 22 FLA; 2 HP, 240 VAC 60 Hz; 80 LRA; 30 FLA; 5 amp tungsten, 120–240 VAC; 470 VA pilot duty, 12–240 VAC; TV-5, 120–240 VAC Carry-over – Non-volatile memory requires no backup. Time keeping and calender data maintained within 0.01% accuracy for minimum of 8 years with one factory installed, field replaceable lithium coin cell. Wiring Terminals – #18 to #10 AWG wire. Applications: • Schools • Offices • Airports • Stores • Hotels • Restaurants • Factories • Parks • Apartments Engineering Specification 365 Day 8 & 16 Circuit Electronic Astronomic Time Switches The time switch shall be a solid state electronic control capable of permitting 4000+ ON/OFF set points to be distributed on independent daily schedules through a 7-day time period and across 99 separate holiday schedules. The time switch shall include a 7-day repeat feature for simplifying programming of identical set points. The time and set points shall be programmable to the nearest minute with a minimum ON duration of 1 minute and a maximum ON duration of 6 days, 23 hours, 59 minutes. The timer shall have a digital LED readout to show day-ofweek and time-of-day using 12/24 hour time format. The time switch shall provide a manual override control for both temporary or permanent override. Time switch shall operate over a temperature range of -40°F (-40°C) to 155°F (68°C). A non-volatile memory shall maintain all program data for the life of the time switch without the need for battery backup. The time switch shall include a factory installed lithium battery backup which shall maintain clock time and calendar data for 8 years minimum. Switch configuration to be SPDT for each circuit with a UL 916 Energy Management Equipment listed rating of: Normally Open Contacts Each Pole; 20 amp resistive/general purpose, 12-277 Volts AC; 20 amp resistive/general purpose, 28 Volts DC; 20 amp ballast, 120-277 VAC; 1 HP, 120 VAC 60 Hz; 98 LRA; 22 FLA; 2 HP, 240 VAC 60 Hz; 80 LRA; 30 FLA; 5 amp tungsten, 120-240 VAC; 470 VA pilot duty, 12-240 VAC; TV-5, 120240 VAC| Normally Closed Contacts 10 Amp Resistive/general purpose, 12-277 VAC; 10 Amp Resistive/general purpose, 28 Volts DC; 3 Amp ballast, 120-277 VAC; 1/4 HP, 120 VAC 60 Hz; 1/2 HP, 240 VAC 60 Hz; 30 LRA; 12 FLA; 275 VA pilot duty, 12-240 VAC. The time switch shall be enclosed in a lockable steel _____ (NEMA 1) (NEMA 3R) enclosure. The time switch shall be powered by a __________ (user selectable 120, 208, 240 or 277 VAC 50 or 60 Hz) (24 VAC 60 Hz) source. The time switch shall be INTERMATIC Model ________________ (ET70815CR or ET70815CR24 8-circuit) (ET71615CR or ET71615CR24 16-circuits). For Controlling: • Water Heaters • Parking Lot Lighting • Commercial Ovens • Interior Lighting • Bells & Signals • HVAC Equipment • Fans/Blowers/Pumps • Livestock Feeders • Poultry Equipment • Process Equipment Model# UL916 E76987 UL917 C22.2-177 LR3730 2.5 lbs 1.1 kg -40°F (-40°C) to 155°F (68°C) ET70415CR1 ET70415CR241 ET70815CR1 ET70815CR241 ET71615CR1 ET71615CR241 Circuits Switch Clock Voltage Amp Rating HP Rating Enclosure 4 4 8 8 16 16 SPDT SPDT SPDT SPDT SPDT SPDT 120/208/240/277 24 120/208/240/277 24 120/208/240/277 24 20 20 20 20 20 20 1HP / 2HP 1HP / 2HP 1HP / 2HP 1HP / 2HP 1HP / 2HP 1HP / 2HP NEMA3R NEMA3R NEMA3R NEMA3R NEMA3R NEMA3R 1 Complies with California Title 24 requirements for multi-level outdoor lighting control. 44 WEATHERPROOF • ENERGY CONTROLS • PROFESSIONAL LIGHTING • POOL & SPA • SURGE PROTECTION • CONSUMER Electronic Energy Controls Next Generation Programming Software NEXT GENERATION ACCESSORIES ET7232M / ET7232M1 RS232 Serial Interface for all Next Generation Time switches. Also used as remote override for 1 & 2 circuit models. Unleash the Power of the Next Generation Time Switch! The NextGen programming software written specifically for installing contractors and maintenance personnel is the fastest and easiest way to program the Intermatic Next Generation series of electronic time switches. Features • Programming of all current Next Generation models (1, 2, 4, 8, & 16 circuits) • Easy point-n-click programming of holiday and daily event schedules • File save function for archiving event schedules for future editing and use • On-line help manual gives easy to follow directions • One-button time and date programming synchronizes the time switch with your PC's date and time LAN Connection to a PC Request Item# 300ET10018 HVAC 156ET9402A 8-Circuit remote override input header. (Not Pictured) 156ET9403A 16-Circuit remote override input header. Facility Manager’s Office Office computers are typically connected through a local area networks (LANs) which provides an in-place backbone to allow control of Next Generation time switches from any linked PC. This applies to office buildings as well as distributed facilities such as university or corporate campuses. NextGen Distributed Control Building Automation Outdoor Lighting Control By linking distributed Next Generation time switches together with the facility manager’s PC the time and associated cost of making periodic schedule changes is greatly reduced and all timing throughout the network can be synchronized to the second with the PC’s internal clock. Networking capabilities allow programming of the Next Generation time switches allowing facility managers to make schedule changes from across the building or campus through an intranet or even across country through the Internet. WEATHERPROOF • ENERGY CONTROLS • PROFESSIONAL LIGHTING • POOL & SPA • SURGE PROTECTION • CONSUMER 45 Electronic Energy Controls Site Lighting Control Panels SiteMaster Site Lighting Control Panels These heavy duty lighting control panels are designed for harsh environmental and lighting load conditions. Features include; Pre-wiring for quick installation, heavy-duty NEMA 3R enclosures, mercury or “Ice Cube” relays, agency approved disconnect, 40, 80, 120 Amp design, locking hasps, and dead-front storage. Mechanical or electronic timing, lightning arrester, photo control, and stainless steel options. SM2200 Series Specifications Gasketless panel with two 20 Amp DPST Relays. Pre-wired with one 20 Amp double-pole Square D Homeline™ main breaker. 120 V output: one twin 20 Amp breaker & one single-pole 20 Amp breaker (for 240 V output- quad breaker with common trip on outside and inside). Capable of controlling 40 Amps @ 120 V and 20 Amps @ 240 V or 12- 400 Watt HID fixtures. SM4400 Series Specifications Gasketless panel with two 20 Amp DPST Relays. Pre-wired with one 40 Amp double-pole Square D Homeline™ main breaker. 120 V output: Six single-pole 20 Amp breakers (240 V output: three double-pole 20 Amp breakers). Capable of controlling 80 Amps @ 120 V and 40 Amps @ 240 V or 24- 400 Watt HID fixtures. SM6600 Series Specifications Gasketless panel with one 60 Amp DPST mercury relay. Split buss service- Upper buss. 120 V output: Pre-wired with one 60 Amp double-pole Square D Homeline™ main breaker and one-single pole 20 Amp breaker (240 V output: one 60 Amp double-pole and one 20 Amp double-pole breaker) Lower Buss - for load connections. Eight single-pole 20 Amp breakers (for 240 V output - four double-pole breakers). Capable of controlling 120 Amp @ 120 V and 60 Amps @ 240 V or 36- 400 Watt HID fixtures. SM6240DOT & SM6277DOT Series Specifications Gasketless 14 AWG stainless-steel panel with 3-point locking system. SM6240DOT: 60 Amp DPST mercury relay. Split buss service- Upper buss. 120 V output: Pre-wired with one 60 Amp double-pole Square D Homeline™ main breaker and one single-pole 20 Amp breaker. Lower Buss - for load connections: Four double-pole 20 Amp breakers. Capable of controlling 60 Amps @ 240 V or 36- 400 Watt HID fixtures. Pre-installed 15 Amp GFCI duplex convenience receptacle. SM6277DOT: 60 Amp 3PST mercury relay. Input power 480/277 V 3-Phase: Pre-wired with one 60 Amp 3-Phase main breaker and one single-phase 20 Amp breaker. Load Output: Six 20 Amp 277 V Single-Phase breakers. Capable of controlling 180 Amps @ 277 V or 54- 400 Watt HID fixtures. Applications: • Schools • Offices • Airports • Stores • Hotels • Restaurants • Factories • Apartments • Electrical Utilities • Municipalities Engineering Specification Site Lighting Control Panel The site lighting control panel shall incorporate agency approved disconnect means with lockout capability, branch circuit breakers for feeding connected lighting loads, electrically held contactor suitable for switching attached loads, and timing mechanism for control of said contactor. The control panel shall be pre-wired for installation convenience and reliability. The control panel shall be designed to accept a variety of timing mechanisms including mechanical and electronic. The control panel and all related components shall operate over a temperature range of -31°F (-35°C) to 130°F (54°C). The capacity of each branch circuit within the control panel shall be 20 amps minimum. The control panel shall be a lockable steel NEMA 3R enclosure. The control panel shall be INTERMATIC Model ________________ (SM2200x-x 2-branch; 4,800 Watt HID) (SM4400x-x 6-branch; 9,600 Watt HID) (SM6600x-x 8-branch; 14,400 Watt HID) (SM6240DOT) (SM6277DOT). For Controlling: • Roadway Lighting • Parking Structures • Parking Lots • Billboards • Entertainment Venues • Ball Fields • Driving Ranges • Parks • Outdoor Area Lighting C22.2-177 LR3730 46 -40°F (-40°C) to 130°F (54°C) WEATHERPROOF • ENERGY CONTROLS • PROFESSIONAL LIGHTING • POOL & SPA • SURGE PROTECTION • CONSUMER Electronic Energy Controls Pre-Wired For Faster Installations Model# Time Switch/Description SM2200*1 SM2200*2 SM2200*3 SM2200*4 SM2200*5 SM2200*6 SM2200*7 SM2200*8 SM2200*16 T103M Mechanical Time Switch T103M Mechanical Time Switch ET101CM Electronic Time Switch ET101CM Electronic Time Switch ET279C Electronic Time Switch ET279C Electronic Time Switch ET104CM Electronic Time Switch ET104CM Electronic Time Switch ET8215CM Astronomic Time Switch Model# Time Switch/Description SM4400*1 SM4400*2 SM4400*3 SM4400*4 SM4400*51 SM4400*61 SM4400*7 SM4400*81 SM4400*91 SM4400*10 SM4400*11 SM4400*12 SM4400*13 SM4400*141 SM4400*16 T103M Mechanical Time Switch T103M Mechanical Time Switch ET101CM Electronic Time Switch ET101CM Electronic Time Switch ET279C Electronic Time Switch ET279C Electronic Time Switch ET70115C Electronic Astro Time Switch ET70215C Electronic Astro Time Switch ET70215C Electronic Astro Time Switch T104M Mechanical Time Switch T104M Mechanical Time Switch ET104CM Electronic Time Switch ET104CM Electronic Time Switch ET70215C Electronic Astro Time Switch ET8215CM Astronomic Time Switch Model# Time Switch/Description SM6600*1 SM6600*2 SM6600*3 SM6600*4 SM6600*5 SM6600*6 SM6600*71 SM6600*81 SM6600*9 SM6600*101 SM6600*16 T103M Mechanical Time Switch T103M Mechanical Time Switch ET101CM Electronic Time Switch ET101CM Electronic Time Switch ET104CM Electronic Time Switch ET104CM Electronic Time Switch ET279CM Electronic Time Switch ET279CM Electronic Time Switch ET70115C Electronic Astro Time Switch ET70215C Electronic Astro Time Switch ET8215CM Astronomic Time Switch # Outputs Output VAC Photo Control 2 2 2 2 2 2 1 1 2 120 VAC 120 VAC 120 VAC 120 VAC 120 VAC 120 VAC 240 VAC 240 VAC 120 VAC No Yes No Yes No Yes No Yes No # Outputs Output VAC Photo Control 4 4 4 4 4 4 4 4 4 2 2 2 2 2 4 120 VAC 120 VAC 120 VAC 120 VAC 120 VAC 120 VAC 120 VAC 120 VAC 120 VAC 240 VAC 240 VAC 240 VAC 240 VAC 240 VAC 120 VAC No Yes No Yes No Yes No No Yes No Yes No Yes No No # Outputs Output VAC Photo Control 8 8 8 8 4 4 8 8 8 8 8 120 VAC 120 VAC 120 VAC 120 VAC 240 VAC 240 VAC 120 VAC 120 VAC 120 VAC 120 VAC 120 VAC No Yes No Yes No Yes No Yes No No No 1 Two independent circuits for bi-level or 2-sided control. Complies with California Title 24 requirements for multi-level outdoor lighting control SM2200*7 Standard Steel Case – Stainless-Steel Case S Lightning Arrestor Option LA Lightning Arrester & Stainless-Steel LAS SITE LIGHTING PANEL TIME SWITCH OPTIONS Mechanical, Electronic, & Astronomic Field Changeable Mechanisms Panel Dimensions SM2200 C22.2-177 LR3730 4.75” 9” SM4400 C22.2-177 LR3730 17” SM4400*7 Standard Steel Case – Stainless-Steel Case S Lightning Arrestor Option LA Lightning Arrester & Stainless-Steel LAS SM6600*7 Standard Steel Case – Stainless-Steel Case S Lightning Arrestor Option LA Lightning Arrester & Stainless-Steel LAS 15” 11” 4.75” SM6600 C22.2-177 LR3730 28” 13” 5” WEATHERPROOF • ENERGY CONTROLS • PROFESSIONAL LIGHTING • POOL & SPA • SURGE PROTECTION • CONSUMER 47 In-Wall Electrical Devices Spring Wound Auto-Off Timers FD Decorator Series Auto-Off Timers These energy saving timers use no electricity to operate. These timers are designed to replace any standard wall switch, single or multi-gang, and automatically limit the “ON” time of fans, lights, motors, heaters and other energy consuming loads. Time limits of 5, 15, 30 and 60 minutes and 2, 4, 6 and 12 hours are available. The “hold feature” allows the user to override the automatic shut-off function for extended use of the load as required. Supplied with a molded white, ivory or almond time dial plate designed to fit either toggle or decorator style switch plates; single or multi-gang with no field modifications required to fit either style switch plate. Time saving “up front” terminal connection with teeter type terminals and an easy “press-on” knob design ensure quick and easy installation. Specifications Switch Rating – Inductive: 20 Amp 125 VAC 50/60 Hz; 10 Amp 250 VAC 50/60 Hz; 10 Amp 277 VAC 50/60 Hz, Tungsten: 7 Amp 125 VAC, Motor: 1 HP 125 VAC 50/60 Hz; 2 HP 250 VAC 50/60Hz Caution: Do not use for sunlamps, sauna, etc... Colors – Available in White, Ivory, and Almond Style – Decorator Styling - Can be used with decorator or toggle type switch plates. Applications: • Indoor Lighting • Outdoor Lighting • Lighting Overrides • Exhaust Fans • Whole House Fans • Ventilating Fans • Tennis Court Lighting • Pumps • Air Conditioners • Steam Rooms • Bathroom Fans • Whirlpools • Porch Lights • Broom Closets • Carriage Lights • Television Sets • Self Storage Units • Engine Block Heaters • Process Controls UL916 E76987 C22.2-177 LR3730 Engineering Specification Spring Wound Auto Shut-Off Timer (a.k.a. Interval Timer). Provide and install as indicated a mechanical spring wound timer that requires no electricity to operate the timing mechanism. The timer shall be supplied with a threaded shaft. The timer must be able to fit a standard 2-1/2 inch deep wall box and accept a rectangular decorator wall plate, standard toggle switch plate or be capable of mounting easily in a panel board. Timer contacts shall break current at the end of timed cycle. Various timing ranges and switch contact arrangements shall be available up to 12 hours, with or without “HOLD” feature for constant ON. Timer shall be Intermatic Model FD______ (Fill in for required time range, contact arrangement and color). Time Cycle IVORY without hold with hold 2.5 lbs 1.1 kg -40°F (-40°C) to 155°F (68°C) WHITE without hold with hold SPST 5 minute FD5M N/A FD5MW N/A 15 minute FD15MC FD15MH FD15MWC FD15MHW 30 minute FD30MC FD30MH FD30MWC FD30MHW 60 minute FD60MC FD60MH FD60MWC FD60MHW 2 hour FD2H N/A FD2HW N/A 4 hour FD4H N/A FD4HW N/A 6 hour FD6H FD60HH FD6HW FD6HHW 12 hour FD12HC FD12HH FD12HWC FD12HHW SPDT Can be used as a normally closed for “Reverse Action” applications 2 hour FD32H N/A FD32HW N/A 4 hour FD34H N/A FD34HW N/A 6 hour FD36H N/A FD36HW N/A 12 hour N/A N/A FD312HW N/A DPST 15 minute FD415M N/A N/A N/A 30 minute FD430M N/A FD430MW N/A 60 minute FD460M N/A FD460MW N/A 6 hour FD46H N/A FD46HW N/A 12 hour N/A N/A N/A N/A ALMOND without hold only N/A FD15MAC FD30MAC FD60MAC N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A Decorator (FD) timers shipped with timer, color coordinated time dial and knob. 48 WEATHERPROOF • ENERGY CONTROLS • PROFESSIONAL LIGHTING • POOL & SPA • SURGE PROTECTION • CONSUMER In-Wall Electrical Devices Spring Wound Auto-Off Timers FF Commercial Series Auto-Off Timers These energy saving commercial timers use no electricity to operate. These timers are designed to replace any standard wall switch, single or multi-gang, and automatically limit the “ON” time of fans, lights, motors, heaters and other energy consuming loads. Time limits of 5, 15, 30 and 60 minutes and 2, 4, 6 and 12 hours are available. The “hold feature” allows the user to override the automatic shut-off function for extended use of the load as required. Rugged time-dial plate takes the abuse encountered in commercial environments. Time saving “up front” terminal connection with teeter type terminals and an easy “press-on” knob design ensure quick and easy installation. Specifications Switch Rating – Inductive: 20 Amp 125 VAC 50/60 Hz; 10 Amp 250 VAC 50/60 Hz; 10 Amp 277 VAC 50/60 Hz, Tungsten: 7 Amp 125 VAC, Motor: 1 HP 125 VAC 50/60 Hz; 2 HP 250 VAC 50/60Hz Caution: Do not use for sunlamps, sauna, etc... Colors – Commercial “brush metal” look. Style – New simulated metal finish meets NEC requirements. Engineering Specification Spring Wound Auto Shut-Off Timer (a.k.a. Interval Timer). Provide and install as indicated a mechanical spring wound timer that requires no electricity to operate the timing mechanism. The timer shall be supplied with a threaded shaft. The timer must be able to fit a standard 2-1/2 inch deep wall box with commercial wall plate or be capable of mounting easily in a panel board. Timer contacts shall break current at the end of timed cycle. Various timing ranges and switch contact arrangements shall be available up to 12 hours, with or without “HOLD” feature for constant ON. Timer shall be Intermatic Model FF______ SPST 5 Minute 15 Minute 30 Minute 60 Minute 2 Hour 4 Hour 6 Hour 12 Hour SPDT 15 Minute 30 Minute 60 Minute 2 Hour 4 Hour 6 Hour 12 Hour Each space enclosed by ceiling height partitions shall have at least one control device to independently control the general lighting within the space. Each control device shall be activated either manually by an occupant or automatically by sensing an occupant. Each control device shall: (Fill in for required time range and contact arrangement). Time Cycle ASHRAE 90.1-1999 Section 9.2.1.2 Space Control Without Hold With Hold Without Hold FF5M FF15MC FF30MC FF60MC FF2H FF4H FF6H FF12HC FF5MH FF15MH FF30MH FF60MHC N/A N/A FF6HH FF12HHC DPST N/A FF415M FF430M FF460M N/A N/A FF46H FF412H FF315M FF330M FF360M FF32H FF34H FF36H FF312H N/A N/A N/A FF32HH FF34HH N/A FF312HH With Hold N/A N/A N/A N/A N/A N/A N/A N/A (a) control a maximum of 2,500 sq ft area for a space 10,000 sq ft or less and a maximum of 10,000 sq ft area for a space greater than 10,000 sq ft, (b) be capable of overriding the shutoff control required in 9.2.1.1 for no more than four hours, and (c) be readily accessible and located so the occupant can see the controlled lighting for a maximum of four hours. WEATHERPROOF • ENERGY CONTROLS • PROFESSIONAL LIGHTING • POOL & SPA • SURGE PROTECTION • CONSUMER 49 In-Wall Electrical Devices Electronic Auto-Off Timers EI200 Series Decorator Electronic Auto-Off Timer The EI200 series timers provide silent operation in time ranges from 30 minutes up to 12 hours. Four basic models available in three colors reduce the need to stock as many timers, freeing up shelf space and providing more specification flexibility. Replaces single-pole switches in a variety of applications. Specifications Switch – Single-pole Switch Rating – Resistive (heater): 15 Amp, 120 VAC 1800 Watts; Tungsten (incandescent): 8.3 Amp, 120 VAC 1000 Watts; Ballast (Fluorescent): 8 Amp, 120 VAC; Motor: 1/4 H.P., 120 VAC; Caution: Do not use for sunlamps, sauna, etc... Colors – Available in White, Ivory, and Light Almond Style – Decorator Styling. Special Voltages and Cycles – 50 or 60 Hz. ASHRAE 90.1-1999 Section 9.2.1.2 Space Control Each space enclosed by ceiling height partitions shall have at least one control device to independently control the general lighting within the space. Each control device shall be activated either manually by an occupant or automatically by sensing an occupant. Each control device shall: (a) control a maximum of 2,500 sq ft area for a space 10,000 sq ft or less and a maximum of 10,000 sq ft area for a space greater than 10,000 sq ft, (b) be capable of overriding the shutoff control required in 9.2.1.1 for no more than four hours, and (c) be readily accessible and located so the occupant can see the controlled lighting for a maximum of four hours. UL916 E76987 -32°F (0°C) to 158°F (70°C) 2.5 lbs 1.1 kg Engineering Specification Electronic Auto Shut-Off Timer (a.k.a. Interval Timer). Provide and install as indicated an electronic timing mechanism. The timer shall be supplied with an LED display and single-button operation. The timer must be able to fit a standard wall box and accept a rectangular decorator wall plate. Timer contacts shall break current at the end of timed cycle. Timer shall be capable of single-pole operation. Various user selectable timing ranges shall be available up to 12 hours, with or without “HOLD” feature for constant ON. Timer shall be Intermatic Model ______ (For 5/10/15/30 Minute EI200 - Ivory, EI200W - White, EI200LA - Light Almond; For 10/20/30/60 Minute EI210 - Ivory, EI210W - White, EI210LA - Light Almond; For 1/2/4/8 Hour EI220 - Ivory, EI220W - White, EI220LA - Light Almond; For 2/4/8/12 Hour EI230 - Ivory, EI230W - White, EI230LA - Light Almond). Model# Time Range Switch EI200 EI200W EI200LA EI205* EI205W* EI205LA* EI210 EI210W EI210LA EI215** EI215W** EI215LA** EI220 EI220W EI220LA EI230 EI230W EI230LA 5/10/15/30 Minute 5/10/15/30 Minute 5/10/15/30 Minute 5/15/30/45/60 Minute 5/15/30/45/60 Minute 5/15/30/45/60 Minute 10/20/30/60 Minute 10/20/30/60 Minute 10/20/30/60 Minute 15/30/60 Minute, 2/4Hour 15/30/60 Minute, 2/4Hour 15/30/60 Minute, 2/4Hour 1/2/4/8 Hour 1/2/4/8 Hour 1/2/4/8 Hour 2/4/8/12 Hour 2/4/8/12 Hour 2/4/8/12 Hour Single-Pole Single-Pole Single-Pole Single-Pole Single-Pole Single-Pole Single-Pole Single-Pole Single-Pole Single-Pole Single-Pole Single-Pole Single-Pole Single-Pole Single-Pole Single-Pole Single-Pole Single-Pole Clock Voltage Max Wattage Color HOLD 120 VAC 120 VAC 120 VAC 120 VAC 120 VAC 120 VAC 120 VAC 120 VAC 120 VAC 120 VAC 120 VAC 120 VAC 120 VAC 120 VAC 120 VAC 120 VAC 120 VAC 120 VAC 1,800 1,800 1,800 1,800 1,800 1,800 1,800 1,800 1,800 1,800 1,800 1,800 1,800 1,800 1,800 1,800 1,800 1,800 Ivory White Light Almond Ivory White Light Almond Ivory White Light Almond Ivory White Light Almond Ivory White Light Almond Ivory White Light Almond Yes Yes Yes No No No Yes Yes Yes No No No Yes Yes Yes Yes Yes Yes * Meets or exceeds CEC Title 24, ASHRAE 90.1 and IECC requirements for enclosed spaces. ** Meets or exceeds ASHRAE 90.1 Requirements for enclosed spaces. 50 WEATHERPROOF • ENERGY CONTROLS • PROFESSIONAL LIGHTING • POOL & SPA • SURGE PROTECTION • CONSUMER In-Wall Electrical Devices 24-Hour Mechanical Time Switches Compact Mechanical In-Wall Time Switches These compact heavy-duty 24-hour timers can be used to turn on lights, fans, pumps and other heavy-duty loads for energy savings, security and convenience. Its compact, quiet, low profile design has easy to set tabs for precise 24-hour control. Models are available for single gang, 2-gang and dual timer applications. Easy set tabs provide for minimum on/off times of 20 minutes for up to 36 ON/OFF events daily. A manual ON or OFF override provides for permanent on or off override of loads at any time. Three models; E1120 - a single timer model, E1220 - a single timer with a 2-gang switch plate for a toggle switch, and E1221 - a single timer with a 2-gang switch plate for a decorator switch. All four models include a white metal single or 2-gang switch plate as required. The toggle or decorator switch is not included with timers. Model E1221 with decorator switch plate can be wired to control a decorator style receptacle or GFCI receptacle to provide for “timed receptacle” control. Specifications Size – All models 1-1/4" (3.18 cm) Deep. Model E1120 - 4-1/2" (11.43 cm) H, 2-3/4" (6.99 cm) W; Models E1220, E1221 and E1222 - 4-1/2" (11.43 cm) H, 4-9/16" (11.59 cm) W. Switch Rating – 120 Volt AC, 60 Hz, 15 Amps, 1875 Watts Resistive 1350 Watts Tungsten, 1/2 HP Motor Load, 8 Amp Inductive Manual Control – Timers can be turned on and off manually for temporary or permanent control. Color – White switch plate and trippers, black dial. Model# Plate Only E1120 E1220 E1221 24EB5495 24EB5497 24EB5524 Switch Volts /60Hz Amps Max Wattage Min. On/Off Time Max. On/Off Time SPST SPST SPST 120 120 120 15 15 15 1875 1875 1875 20 mins. 20 mins. 20 mins. 23 hrs. 40 mins. 23 hrs. 40 mins. 23 hrs. 40 mins. ASHRAE 90.1-1999 Section 9.2.1.1 Automatic Lighting Shutoff Interior lighting in buildings larger than 5,000 sq. ft. shall be controlled with an automatic control device to shut off building lighting in all spaces. This automatic control device shall function on either; (a) a time-of-day operated control device that turns lighting off at specific programmed times, and independent program schedule shall be provided for areas of no more than 25,000 sq ft but not more than one floor or (b) an occupant sensor that shall turn lighting off within 30 minutes of an occupant leaving a space or (c) by occupant intervention. Heavy Duty In-Wall Time Switches UL916 C22.2-177 2.5 lbs E76987 LR3730 1.1 kg These heavy duty timers can be used to turn on lights, fans, pumps and other heavy duty loads for energy savings, security and convenience. The timer is designed to mount to any standard junction box for replacing a wall switch. Models are available in single ON / OFF or multiple ON / OFF type. Both models have an easy to use manual override. Model E1010 equipped with a 24 hour dial divided in half-hour increments with a permanently attached “ON” and “OFF” tripper permitting single “ON / OFF” control every 24 hours. Model E1020 equipped with a multiple program dial. The dial accommodates 12 “ON” and 12 “OFF” trippers. Furnished with two “ON” and two “OFF” trippers. Both timers have three color code leads and require a hot, neutral and one side of the load. Applications: For Controlling: Specifications Size – 4-1/4" (10.8 cm) High, 3-1/4" (9.5 cm) Wide, 1-3/8" (3.5 cm) Deep. Switch Rating – 120 VAC 60 Hz; 1440 Watts Tungsten; 12 Full load Amps.; 15 Amp max load. Timing Cycle – Minimum “ON” time 1/2 hour, maximum “ON” time 22-1/2 hours; Minimum time between any two “ON” trippers (and any two “OFF” trippers) is 2 hours. Model# E1010 E1020 Switch Volts Amps Max Wattage Color SPST SPST 120 120 15 15 1800 1800 Stonedust white housing Stonedust white housing • Schools • Offices • Airports • Stores • Hotels • Restaurants • Parks • Apartments For additional trippers for E1020 (2 “ON” / 2 “OFF” per pack), order No. 156EB1945A. • Hall Lights • Ceiling Lights • Whole House Fans • Paddle Fans • Porch Lights • Outdoor Lights • Air Conditioners • Coffee Makers • Boilers • Attic Fans • Industrial Fans • Automated Control UL917 2.5 lbs C22.2-177 1.1 kg LR3730 WEATHERPROOF • ENERGY CONTROLS • PROFESSIONAL LIGHTING • POOL & SPA • SURGE PROTECTION • CONSUMER 51 In-Wall Electrical Devices 24-Hour Mechanical Time Switches EI500 Series Decorator Digital 7-Day Time Switch The EI500 series compact 7-day timers provides up to 7-ON and 7-OFF operations per week which can be used for 24-hour or 7-day load control of lights, fans, pumps, and other medium-duty loads for energy savings, security, and convenience. Its compact, quiet, low profile design is easy to program for to-the-minute 24-hour or 7-day control. In addition, the display continuously shows time of day, day of the week, timer load and the load status. Available in three colors white, ivory, and light almond. Replaces single-pole switches in a variety of applications. Specifications ASHRAE 90.1-1999 Section 9.2.1.1 Automatic Lighting Shutoff Interior lighting in buildings larger than 5,000 sq ft shall be controlled with an automatic control device to shut off building lighting in all spaces. This automatic control device shall function on either; (a) a time-of-day operated control device that turns lighting off at specific programmed times, and independent program schedule shall be provided for areas of no more than 25,000 sq ft but not more than one floor or (b) an occupant sensor that shall turn lighting off within 30 minutes of an occupant leaving a space or (c) by occupant intervention. UL916 E76987 52 32°F (0°C) to 158°F (70°C) Switch – Single-pole Switch Rating – Resistive (heater): 15 Amp, 120 VAC 1800 Watts; Tungsten (incandescent): 8.3 Amp, 120 VAC 1000 Watts; Ballast (fluorescent): 8 Amp, 120 VAC; Motor: 1/4 H.P., 120 VAC; Caution: Do not use for sunlamps, sauna, etc... Events – 7 ON & 7 OFF Events per Day. Colors – Available in White, Ivory, and Light Almond Style – Decorator Styling. Special Voltages and Cycles – 50 or 60 Hz. Engineering Specification Electronic 7-Day Timer. The timer switch shall be a solid state electronic control capable of permitting 7-ON and 7-OFF set points to be distributed through a 7-day time period. The time and set points shall be programmable to the nearest minute with a minimum ON duration of 1 minute and a maximum ON duration of 6 days, 23 hours, 59 minutes. The timer shall have a backlit digital LCD readout to show day-of-week and time-of-day using 12 hour AM/PM indicator. The time switch shall provide a manual override control for both temporary or permanent override. Time switch shall operate over a temperature range of 32°F (0°C) to 158°F (70°C). An internal rechargeable battery shall protect program information and time-of-day for a minimum of 36 hours. Switch configuration to be SPST with a UL listed rating of: 20 amp Resistive, 120 Volts AC, 50/60 Hz; 15 amps Resistive, 120 Volts AC, 50/60 Hz; 1/4 HP, 120 Volts AC, 50/60 Hz; 8.3 amps Tungsten, 120 Volts AC, 50/60 Hz; 10 amps Ballast, 120 Volts AC, 50/60 Hz The timer must be able to fit a standard wall box and accept a rectangular decorator wall plate. Timer contacts shall make or break current according to user adjustable program. Timer shall be Intermatic Model ______ (Ivory - EI500, White - EI500W, Light Almond - EI500LA) Model# Switch Clock Voltage Max Wattage Color EI500C EI500WC EI500LAC Single-Pole Single-Pole Single-Pole 120 VAC 50/60 Hz 120 VAC 50/60 Hz 120 VAC 50/60 Hz 1,800 1,800 1,800 Ivory White Light Almond 2.5 lbs 1.1 kg WEATHERPROOF • ENERGY CONTROLS • PROFESSIONAL LIGHTING • POOL & SPA • SURGE PROTECTION • CONSUMER In-Wall Electronic Devices 7-Day Electronic Time Switch EI600 Series Decorator Electronic 7-Day Astro Time Switch This easy to program timer provides up to 40 ON/OFF operations per week which can be used for 24-hour or 7-day load control. The astronomic feature provides sunset ON and sunrise OFF settings and the auto daylight savings adjustment means you can “set-it and forget-it”. The independant 7-day programming provides complete flexibility for applications where load switching differs each day of the week. Astronomic programming can be combined with independant programs to provide a sunset ON and timed OFF program. A factory supplied CR2 lithium battery provides up to three years of time keeping without AC power and user program selections are stored in non-volatile memory. A low battery indicator appears in the display when the battery requires replacement. In addition, the display continuously shows time of day, day of the week, timer load and the load status. The timer has an isolated single pole single throw switch which allows the timer to switch any load type, including PAR lamps and motor loads from 12 to 277 volts AC or 12 to 28 volts DC, within the specified ratings. A “3 wire” design allows the timer to replace, or be used as a single-pole or 3way (multi-way) switch. Applications: Specifications • Schools • Offices • Airports • Stores • Hotels • Restaurants • Parks • Apartments Switch – Single-pole or 3-way (Multi-way) Compatable Switch Rating – Resistive (heater): 20 Amp, 120-277 VAC Tungsten (incandescent): 15 Amp, 120 VAC; 6 Amp, 208-277 VAC Ballast (fluorescent): 16 Amp, 120-277 VAC Motor: 1 H.P., 120 VAC; 2 H.P., 240 VAC; 4 Amp, DC Loads:12 VDC; 2 Amp, 28 VDC Caution: Do not use for sunlamps, sauna, etc... Events – 40 ON/OFF Events per week. Colors – Available in White, Ivory, and Light Almond Style – Decorator Styling. Special Voltages and Cycles – 50 or 60 Hz. Warranty – 5 Years For Controlling: Engineering Specification Electronic 7-Day astronomic Timer. The timer switch shall be a solid state electronic control capable of permitting 40 ON/OFF set points to be distributed through a 7-day time period with 1 astro ON and 1 astro OFF set point per day. The time and set points shall be programmable to the nearest minute with a minimum ON duration of 1 minute and a maximum ON duration of 6 days, 23 hours, 59 minutes. The timer shall have a digital LCD readout to show day-of-week and time-of-day using 12 hour AM/PM indicator. The time switch shall provide a manual override control for both temporary or permanent override. Time switch shall operate over a temperature range of 32°F (0°C) to 104°F (40°C). A lithium battery provides up to three years of time keeping without AC power and user program selections are stored in a non-volatile memory. Switch configuration to be SPST with a UL listed rating of: Resistive (heater): 20 Amp,120-277 VAC; Tungsten (incandescent):15 Amp, 120 VAC; 6 Amp, 208-277 VAC; Ballast (Fluorescent): 16 Amp, 120-277 VAC; Motor: 1 H.P., 120 VAC; 2 H.P., 240 VAC; 4 Amp, DC Loads: 12 VDC; 2 Amp, 28 VDC. The timer must be able to fit a standard wall box and accept a rectangular decorator wall plate. Timer contacts shall make or break current according to user adjustable program. Timer shall be Intermatic Model ______ (Ivory - EI600, White - EI600W, Light Almond - EI600LA) • Indoor Lighting • Outdoor Lighting • Pumps & Fans • HID Lighting • Library Lights • Classroom Lights • Fluorescent Lighting • PAR Lights • Heaters • Recreational Vehicles • Air Conditioners • Porch Lights • Carrage Lights UL917 C22.2-177 LR3730 Model# Switch Contact Max Wattage Color EI600C EI600WC EI600LAC Single-Pole / 3-way Single-Pole / 3-way Single-Pole / 3-way 12 - 277 VAC;12 - 28 VDC 12 - 277 VAC;12 - 28 VDC 12 - 277 VAC;12 - 28 VDC 1,800 - 4,155 1,800 - 4,155 1,800 - 4,155 Ivory White Light Almond 32°F (0°C) to 158°F (70°C) 2.5 lbs 1.1 kg WEATHERPROOF • ENERGY CONTROLS • PROFESSIONAL LIGHTING • POOL & SPA • SURGE PROTECTION • CONSUMER 53 InTouch Wireless Controls™ Wireless Home Controls InTouch™ — The Centerpiece for Peaceful Living Z-wave™ makes reliable wireless home control possible. Intermatic makes it a reality with the InTouch™ series of wireless controls. Until now home controls had only two options — reliable controls that were too expensive or low cost controls that were unreliable. That’s all changed with Intermatic’s InTouch wireless controls, which bring reliable controls together with low cost to deliver a home solution everyone can enjoy. Named the Best New Emerging Technology by CNET at the 2006 Consumer Electronic Show, and recipient of the Electronic House Product of the Year Award, Z-wave is a breakthrough technology that enables products from many different manufacturers to seamlessly work together. This same technology lies at the center of Intermatic’s InTouch home control system. Several factors contribute to make Z-wave a breakthrough innovation. First is the “mesh” network, which basically means that every line-powered device within the network acts as a repeater to route signals among distant devices. Second is that Z-wave networks operate in the 900Mhz band, providing a penetrating signal to deliver reliable communications between devices. Another factor is that with more than 4 billion unique house codes, Z-wave provides a secure network with no fear of interference from neighboring systems. Finally, Z-wave has made the leap from theory to reality as more than 100 companies are working in the Z-wave Alliance to develop actual products that benefit homeowners today and in the near future. What this means to homeowners, is they now have all of the convenience, comfort and safety of a reliable home control system without concerns of system reliability, product/ installation costs or compatibility between products. The Intermatic InTouch system helps homeowners “set the scene” for entertaining, working or just relaxing after a long day. Homeowners can now manage and monitor lighting, security systems and other electronics easily, conveniently and securely from anywhere in the world. Functions such as indoor and outdoor lighting, entry access, pool & spa functions, home theater systems, window treatments and heating & cooling are a breeze with Intermatic’s InTouch control system. 54 WEATHERPROOF • ENERGY CONTROLS • PROFESSIONAL LIGHTING • POOL & SPA • SURGE PROTECTION • CONSUMER InTouch Wireless Controls™ Wireless Home Controls Intermatic’s InTouch system has taken Z-wave technology to an even higher level of functionality with the introduction of its patent pending InTouch server technology. The InTouch server provides full two-way, real-time status of every device in the network including legacy Z-wave devices. The InTouch server also makes a host of never before seen features available to the installer and homeowner including: • Greater network range – doubling the number of “hops” a signal can take to get to its target from the Z-wave standard of 4 to 8 • In-field firmware upgrade capability – future-proofing an InTouch network from protocol changes • System text and graphics messaging – allowing streaming information such as sports scores, stock quotes, weather and news alerts as well as personal and system status messages • Centralized scene and status information – ability to remotely edit scenes from anywhere in the network • Full Z-wave compatibility – adding an InTouch Server to any manufacturer’s Z-wave product instantly upgrades their capabilities to share many of the InTouch features Imagine arriving home from a long day’s work and as you step inside, the temperature of the room is just right, the lighting level is relaxed and inviting, your audio system is playing your favorite song, the shades are being drawn for the evening and your spa is warm and bubbling. At Intermatic, we call this living the InTouch lifestyle. Previous home controls systems capable of providing a similar level of service as InTouch were expensive, took weeks to install and didn’t deliver the same functionality. InTouch provides the safety, security and convenience homeowners are looking for while making it priceaccessible for everyone. With an InTouch residential controls package from Intermatic, electrical contractors, designers, home builders and custom installers can provide homeowners with a robust and intelligent system for a fraction of the cost of current competitive systems. Best of all, the system can be expanded easily to grow with homeowners’ changing needs. And since it’s powered by Z-wave technology, InTouch is 100% compatible with the growing number of Z-wave enabled products. InTouch products are backed by a 10-year warranty and more than 115 years of experience in the electrical industry. The controllers, switches and receptacles are designed to complement any décor and the intuitive controls are designed for minimal programming effort and maximum system functionality. For the Professional installer: • Earn back lost sales by offering customers an affordable, full-bodied system at a price that will shock them for being so affordable. • Easy Installation equals less spent on time and labor.InTouch devices install with existing wiring and both network setup and system programming are quick and easy. • Fewer SKUs means less inventory. Intermatic’s growing line of InTouch products offer changeable faceplates and combination switches to keep the number of devices the distributor or installer needs to inventory to a minimum. • Adaptability makes InTouch the perfect solution for new construction as well as retrofit applications. For the Homeowner: • Advanced technology fosters a progressive lifestyle at a price anyone can afford. • Home controls add value to the home, increasing prestige and resale values. • Reliable and secure control network for consistent comfort, convenience and safety. • Energy savings brought about by improved electrical management. • Easily modified as your electronic needs change and grow. WEATHERPROOF • ENERGY CONTROLS • PROFESSIONAL LIGHTING • POOL & SPA • SURGE PROTECTION • CONSUMER 55 InTouch Wireless Controls™ Wireless Home Controls InTouch™ Residential and Small Business Applications CA5000 Multi-Scene Control CA3000 Lighting Control CA9000 Motion Control CA3500 Appliance Control CA600 Dimming Control CA5100 Multi-Point Control CA3750 Heavy Load Control 56 CA5500BR Portable Command CA7100 Central Command WEATHERPROOF • ENERGY CONTROLS • PROFESSIONAL LIGHTING • POOL & SPA • SURGE PROTECTION • CONSUMER InTouch Wireless Controls™ Wireless Home Controls InTouch™ Product Line CA7100 CA7100 CA600 In-Wall Master Control Wall Dimmer Switch • Features include multiple scene functions, programming based on time, action or a combination of both, along with a full 2-way control system • Built-in astro clock allows lights to go on at sunset and off at sunrise, never having to reset the timer • Voltage: 120 volts 50/60 Hz • Agency approval: FCC, CSA c/us • Offers local and remote scene control, ON/OFF/dim/bright features and LED feedback • The 3-way option allows consumers to control lights from multiple locations, using standard switches, and the mini-scene function allows a light switch to also trigger a small scene of up to five additional devices • Includes three interchangeable faceplates • Colors include White, Ivory and Light Almond • Voltage: 120 volts 50/60 Hz • Rating: 600 W Tungsten • Agency approval: FCC, CSA c/us CA5500BR Hand Held Remote with Smartbase • Offers remote scene control, status feedback and a rechargeable nickel metal hydride battery • The Smartbase also features network memory backup • Agency approval: FCC CA5000 Multi-Button Scene Controller • Offers remote scene control and status feedback • Includes three interchangeable faceplates • Colors include White, Ivory and Light Almond • Voltage: 120 volts 50/60 Hz • Agency approval: FCC, CSA c/us Wall Switch • Includes local and remote scene control, ON/OFF, 3-way option and mini-scenes • Includes three interchangeable faceplates • Colors include White, Ivory and Light Almond • Voltage: 120 volts 50/60 Hz • Rating: 1800 Watts 15A Tungsten; 1800 Watts 15A Resistive/Inductive; 1820VA 15A Ballast; 1/2HP Motor • Agency approval: FCC, CSA c/us CA3500 Accessory Wall Controller Split-Duplex Receptacle CA9000 CA600 CA5000 CA3000 CA5100 CA3500 CA9000 CA3750 CA3000 CA5100 • Features include remote scene control, and mini-scenes • Includes three interchangeable faceplates • Colors include White, Ivory and Light Almond • Voltage: 120 volts 50/60 Hz • Agency approval: FCC, CSA c/us CA5500BR • Features one controlled grounded receptacle and local control • Includes three interchangeable faceplates • Colors include White, Ivory and Light Almond • Voltage: 125 volts 50/60 Hz • Rating: 15 Amps General Purpose • Agency approval: FCC, CSA c/us CA3750 Wireless PIR Sensor • Features remote scene control and adjustable time delay • Requires three AA alkaline batteries • Agency approval: FCC Contactor Module • For large loads such as air conditioners, spas and heaters, the contactor module features a local ON/OFF control and LED feedback • Voltage: 120, 208, 240, 277 volts 50/60 Hz • Rating: 6600 Watts 30 A Resistive; 5500VA 25 Amps Inductive; 5540 Watts 20 Amps @ 277VAC Ballast; 4400 Watts 20 Amps Tungsten; 3HP @ 220VAC Motor • Agency approval: FCC, CSA c/us WEATHERPROOF • ENERGY CONTROLS • PROFESSIONAL LIGHTING • POOL & SPA • SURGE PROTECTION • CONSUMER 57 Your Total Professional Solution Whether you are looking to light a garden pathway or signs along the highway, Intermatic has a comprehensive line of professional lighting to suit your every need. Intermatic recently introduced its line of High Intensity Discharge (HID) lighting to satisfy the growing demand for high quality industrial lighting. With the same high quality that you’ve come to expect from Intermatic controls, Intermatic HID lighting can withstand the harshest elements while providing constant and reliable operation. When married with Intermatic switches and other HID control features like time clocks and photo controls, Intermatic provides a total lighting solution from beginning to end. Intermatic’s Light Expressions™ series of low voltage lighting fixtures is a professional grade series of landscape lighting that blends superior styling with extreme durability. The Light Expressions™ line offers contractors and landscape designers a high-end family of landscape fixtures and transformers to dramatically enhance the appearance of the home, while adding safety and security. With Light Expressions™, one may highlight architecture, trees, sculpture, decks, paths and more. 58 Professional Grade Transformers A Intermatic® professional grade transformers are the most reliable low voltage transformers available. Manufactured by Intermatic Incorporated – recognized worldwide for high quality timers and system controls – these transformers are especially designed for trouble-free operation and long lasting durability. Ensure that all of your professional lighting installations operate trouble-free and provide long-lasting service by using only Intermatic® professional grade transformers. “Your success can depend on it!” B Every professional grade transformer includes these important product features: • Heavy gauge steel housings with rain-tight covers (Model AL60TW uses a high impact polymer construction) • Complete ground shield protection for safe operation. Suitable for use with submersible luminaries or submersible pumps • Suitable for use with submersible luminaries or submersible pumps • Meets UL and cCSAus safety standards • Automatic or resettable circuit breakers for overload protection, helps prevent damage to electrical components, caused by overheating A. AL300TPWS • Heavy-duty 16 ga. stainless steel case • Built-in photo control option • Manual ON/OFF switch • Fully programmable timer • One set of 300 watt terminal blocks • Heavy-duty power cord • 5 Year limited warranty • Resettable circuit breaker • Rain tight enclosure with lifetime limited warranty B. AL600TPWS • Heavy-duty 16 ga. stainless steel case • Built-in photo control option • Manual ON/OFF switch • Fully programmable timer • Two sets of 300 watt terminal blocks • Heavy-duty power cord • 5 year limited warranty • Resettable circuit breaker • Rain tight enclosure with lifetime limited warranty C. AL900TPWS • Heavy-duty 16 ga. stainless steel case • Built-in photo control option • Manual ON/OFF switch • Fully programmable timer • Three sets of 300 watt terminal blocks • Heavy-duty power cord • 5 year limited warranty • Resettable circuit breaker • Rain tight enclosure with lifetime limited warranty C D D. AL300RTW E. AL600TW • Heavy-duty 18 ga. steel housing • Manual ON/OFF switch • Fully programmable timer • One set of 300 watt terminal blocks • Heavy-duty power cord • 5 year limited warranty • Automatic circuit breaker • Rain tight enclosure • Heavy-duty 18 ga. steel housing • Manual ON/OFF switch • Fully programmable timer • Two sets of 300 watt terminal blocks • Heavy-duty power cord • 5 year limited warranty • Automatic circuit breaker • Rain tight enclosure F. AL900TW • Heavy-duty 18 ga. steel housing • Manual ON/OFF switch • Fully programmable timer • Three sets of 300 watt terminal blocks • Heavy-duty power cord • 5 year limited warranty • Automatic circuit breaker • Rain tight enclosure F E All Intermatic AL Transformers meet UL1838 Standards WEATHERPROOF • ENERGY CONTROLS • PROFESSIONAL LIGHTING • POOL & SPA • SURGE PROTECTION • CONSUMER 59 Professional Grade Transformers G. AL60TW G H. AL300MTW • High-impact polymer case • Manual ON/OFF switch • Fully programmable timer • 2 sets of ON/OFF trippers • Automatic circuit breaker • Ground shield protection • Heavy-duty power cord • 5 year limited warranty • Rain tight enclosure TRANSFORMER: • 300VA (True Watts) multi-tap (12V, 13V, 15V) • Heavy 18 ga. painted steel housing • Resettable circuit breaker • Heavy duty power cord code compliant for use with submersible luminaries • Easy hook-up to color coded and labeled leads • Conduit ready with knockouts • 10 year limited warranty on transformer • 600VA (True Watts) multi-tap (12V, 13V, 15V) • Heavy 18 ga. painted steel housing • Resettable magnetic circuit breakers (2) • Heavy duty power cord code compliant for use with submersible luminaries • Easy hook-up to color coded and labeled leads • Conduit ready with knockouts • 10 year limited warranty on transformer INDEPENDENT DIGITAL SELF ADJUSTING INDOOR TIMER: • Set it once, no re-setting required • Automatically adjusts sunrise/sunset times • Automatically adjusts for daylight savings time • Battery back-up included • Easy to read LCD display • One year limited warranty on timer H I. AL600MTW TRANSFORMER: INDEPENDENT DIGITAL SELF ADJUSTING INDOOR TIMER: • Set it once, no re-setting required • Automatically adjusts sunrise/sunset Times • Automatically adjusts for daylight savings time • Battery back-up included • Easy to read LCD display • One year limited warranty on timer J. AL300BW I • High-impact PVC case • Water tight enclosure, can be buried to ground level • Can be controlled externally • Three 1.5” I.D. knockouts for line voltage conduit • Automatic circuit breaker • Ground shield protection for safe operation • 5 year limited warranty J All Intermatic AL Transformers meet UL1838 Standards 60 WEATHERPROOF • ENERGY CONTROLS • PROFESSIONAL LIGHTING • POOL & SPA • SURGE PROTECTION • CONSUMER Professional Landscape Lighting Our Professional Grade Lighting line includes a wide range of weatherproof transformers, low voltage fixtures, specialty insulated cables and a variety of accessories. Intermatic offers an expanded selection of fixtures designed for easy installation. All have the most advanced features that result from our many years of experience in low voltage lighting. AL111 AL115 AL375V AL380C Well Light with 14W Poly-Star bulb Submersible Light with 20W halogen MR16 bulb Metal Light with 18W wedge base bulb and Verde finish Copper Light with 18W wedge base bulb Accessories Low Voltage Cable AL10210 10/2 100 ft. AL102-5C 10/2 500 ft. AL12210 12/2 100 ft. AL385V AL395 AL395V AL401 Brass Light with 18W wedge base bulb and Verde Patina finish Brass Light with 18W wedge base bulb and Aged Brass finish Brass Light with 18W wedge base bulb and Verde Patina finish Metal Floodlight with 35W MR16 bulb and Black finish AL122-5C 12/2 500 ft. AL8-12 Designed specifically for weatherproof, outdoor, hard-wire installations AL1160 AL402 AL402TA AL403 AL403TA Metal Floodlight with 50W PAR36 bulb and Black finish Metal Floodlight with 50W PAR36 bulb and Textured Architectural Bronze finish Metal Floodlight with 35W Halogen MR16 bulb and Black finish Metal Floodlight with 35W Halogen MR16 bulb and Textured Architectural Bronze finish Fixture Ground Stake, 1/2” Female Thread, Heavy Duty Plastic WEATHERPROOF • ENERGY CONTROLS • PROFESSIONAL LIGHTING • POOL & SPA • SURGE PROTECTION • CONSUMER 61 Professional Landscape Lighting 62 AL405 AL405V AL406 AL406TA Brass Light with 18W wedge base bulb and Aged Brass finish Brass Light with 18W wedge base bulb and Verde Patina finish Metal Deck Light with 8W bayonet bulb and Black finish Metal Deck Light with 8W bayonet bulb and Textured Architectural Bronze finish AL407TA AL408TA AL409 AL409TA Metal Cone Walk Light with 18W wedge base bulb and Textured Architectural Bronze finish Metal Dome Walk Light with 18W wedge base bulb and Textured Architectural Bronze finish Metal Bollard Light with 50W MR16 bulb and Black finish Metal Bollard Light with 50W MR16 bulb and Textured Architectural Bronze finish AL425C AL501 AL502 AL502DS Copper Ellipse Light with 18W wedge base bulb Mini Floodlight with 35W halogen MR16 bulb and Black finish Large Floodlight with 50W PAR36 bulb and Black finish Large Floodlight with 50W PAR36 bulb and Dark Sand finish WEATHERPROOF • ENERGY CONTROLS • PROFESSIONAL LIGHTING • POOL & SPA • SURGE PROTECTION • CONSUMER Professional Landscape Lighting AL502TA AL506 AL508V AL510V Large Floodlight with 50W PAR36 bulb and Architectural Bronze finish Metal Floodlight with 35W halogen MR16 bulb and Black finish Large Path Light with 18W wedge base bulb and Verde finish Large Brass Floodlight with 50W PAR36 bulb and Verde finish AL521 AL550 AL550DS AL550TA Cast Metal Acorn Style Path Light with 35W halogen MR16 bulb and Black finish 3 Tier Path Light with 18W wedge base bulb and Black finish 3 Tier Path Light with 18W wedge base bulb and Dark Sand finish 3 Tier Path Light with 18W wedge base bulb and Architectural Bronze finish WEATHERPROOF • ENERGY CONTROLS • PROFESSIONAL LIGHTING • POOL & SPA • SURGE PROTECTION • CONSUMER 63 High Intensity Discharge (HID) Lighting Intermatic’s line of HID lighting is the perfect solution for a wide variety of outdoor lighting needs. In addition, Intermatic has a full array of controls and sensors designed to complement any residential, commercial or industrial lighting system. Wall Packs Ideal for: Parking Areas, Entrances, Walkways, Underpasses, Loading Docks, Recreation Areas and Tunnels. • UL listed for wet locations • Heavy duty die-cast aluminum powder coating construction Part Number WL050MH WL070MH WL100MH WL150MH WL175MH WL250MH WL400MH 64 WL035HPS WL050HPS WL070HPS WL100HPS Wattage Lamp Voltage Finish Lens WL035HPS WL050HPS 35W 50W High Pressure Sodium High Pressure Sodium Bronze Bronze Polycarbonate Polycarbonate WL050MH 50W Metal Halide Bronze Polycarbonate WL070HPS 70W High Pressure Sodium Bronze Polycarbonate WL070MH 70W Metal Halide Bronze Polycarbonate WL100HPS 100W High Pressure Sodium Bronze Glass WL100MH 100W Metal Halide 120V 120V 120/208/240/277V Quad Tap 120/208/240/277V Quad Tap 120/208/240/277V Quad Tap 120/208/240/277V Quad Tap 120/208/240/277V Quad Tap Bronze Glass WL150HPS 150W High Pressure Sodium Bronze Glass WL150MH 150W Metal Halide Bronze Glass WL175MH 175W Metal Halide Bronze Glass WL250HPS 250W High Pressure Sodium Bronze Glass WL250MH 250W Metal Halide Bronze Glass WL400HPS 400W High Pressure Sodium Bronze Glass WL400MH 400W Metal Halide Bronze Glass WL150HPS WL250HPS WL400HPS • Corrosion-resistant hardware • 1/2” tapped holes available for installing photocell (photocell optional) 120/208/240/277V Quad Tap 120/208/240/277V Quad Tap 120/208/240/277V Quad Tap 120/208/240/277V Quad Tap 120/208/240/277V Quad Tap 120/208/240/277V Quad Tap 120/208/240/277V Quad Tap WEATHERPROOF • ENERGY CONTROLS • PROFESSIONAL LIGHTING • POOL & SPA • SURGE PROTECTION • CONSUMER High Intensity Discharge (HID) Lighting Floodlights Ideal for: Buildings, Backyards, Highway Signs, Outdoor Advertising Boards, Parks and Sports Fields • UL and CUL listed for wet locations • Heavy duty die-cast aluminum powder coating construction • Corrosion-resistant hardware Part Number • High impact-resistant tempered glass • Lamp holder E-26, UL approved • Multi-tap ballast: 120/208/240/277 Volts Wattage Lamp Voltage Finish Lens FL035HPS FL050HPS FL070HPS 35W 50W 70W High Pressure Sodium High Pressure Sodium High Pressure Sodium 120V 120V 120V Bronze Bronze Bronze Glass Glass Glass FL050MH 50W Metal Halide Bronze Glass FL070MH 70W Metal Halide Bronze Glass FL100HPS 100W High Pressure Sodium Bronze Glass FL100MH 100W Metal Halide Bronze Glass FL150HPS 150W High Pressure Sodium Bronze Glass FL150MH 150W Metal Halide Bronze Glass FL175MH 175W Metal Halide Bronze Glass FL250HPS 250W High Pressure Sodium FL250MH 250W Metal Halide FL400HPS 400W High Pressure Sodium FL400MH 400W Metal Halide 120/208/240/277V Quad Tap 120/208/240/277V Quad Tap 120/208/240/277V Quad Tap 120/208/240/277V Quad Tap 120/208/240/277V Quad Tap 120/208/240/277V Quad Tap 120/208/240/277V Quad Tap 120/208/240/277V Quad Tap 120/208/240/277V Quad Tap 120/208/240/277V Quad Tap 120/208/240/277V Quad Tap Bronze Glass Bronze Glass Bronze Glass Bronze Glass FL035HPS FL050HPS FL070HPS FL050MH FL070MH FL100MH FL100HPS FL150MH FL175MH FL150HPS FL250MH FL400MH FL250HPS FL400HPS DD175MV DD150HPS Dusk-to-Dawn Lights Ideal for: Perimeter and Security Lighting, Loading Platforms, Barnyards, Parking Lots, Rural Homes, Public Entrances and OFF-Street Parking • UL listed for wet locations • Precision die-cast aluminum housing with natural finish • UV-stabilized PS Lens • 24” arm Part Number DD150HPS DD175MV • Dusk-to-dawn with twist-lock photo control • Mounting hardware included • Lamp holder E-39, 4KV and UL approved • 120 Volt fixture Wattage Lamp Voltage Lens Arm 150W 175W High Pressure Sodium Mercury Vapor 120V 120V Polycarbonate Polycarbonate 24” 24” WEATHERPROOF • ENERGY CONTROLS • PROFESSIONAL LIGHTING • POOL & SPA • SURGE PROTECTION • CONSUMER 65 High Intensity Discharge (HID) Lighting Quartz Floodlights Ideal for: Building Facades, Signs, Sports Fields and Emergency and Temporary Floodlighting FL150Q • UL and CUL listed for wet locations • Die-cast aluminum construction • Tempered door glass • Hinged front door Part Number FL300Q FL500Q FL150Q FL300Q FL500Q • 1/2” threaded swivel mount • Dark bronze finish • 120 Volt fixture Wattage Lamp Voltage Finish Lens 150W 300W 500W Quartz Halogen Quartz Halogen Quartz Halogen 120V 120V 120V Bronze Bronze Bronze Glass Glass Glass Canopy Lights Ideal for: Parking Areas, Entrances, Walkways, Underpasses, Loading Docks and Recreation Areas • UL listed for wet locations • Heavy duty die-cast aluminum powder coating construction • High impact polycarbonate lens • Corrosion-resistant hardware Part Number Wattage Lamp Voltage Finish Lens High Pressure Sodium 120/208/240/277V Quad Tap Bronze Polycarbonate CP150HPS CP150HPS 150W • 1/2” tapped holes available for installing photocell (photocell optional) • multi tap ballast: 120/208/240/277 Volts Wall Fixture with Photocell Ideal for: Parking Areas, Entrances, Walkways, Underpasses, Loading Docks and Recreation Areas WL070HPSPC 66 • UL listed for wet locations • High-impact polycarbonate lens and housing • Aluminum baseplate with conduit access • Corrosion-resistant hardware • 120 Volt installed photocell included • Multi-tap ballast: 120 Volt fixture Part Number Wattage Lamp Voltage Finish Lens WL070HPSPC 70W High Pressure Sodium 120V Bronze Polycarbonate WEATHERPROOF • ENERGY CONTROLS • PROFESSIONAL LIGHTING • POOL & SPA • SURGE PROTECTION • CONSUMER Helping Maintain the Luxuries of Life Few things exceed the pleasure of a refreshing dip in the pool on a hot summer day or a relaxing soak in the hot tub on a chilly evening. Intermatic helps maintain these luxuries with a variety of reliable controls, which combine economy and flexibility in a single enclosure. Too often, as technology advances, controlling that technology becomes exceedingly complex. Intermatic has made a commitment to provide its customers with controls that are as easy to install as they are to use. While maintaining its reputation for reliability, Intermatic designs innovative pool and spa controls that are powerful and intuitive. Providing simple, focused controls allows the consumer to purchase only the features they need for their application – saving money and easing frustration. Intermatic’s products are flexible and designed to work together cohesively in an endless number of scenarios. Intermatic controls reduce installation costs and maintain consistent performance for aeration, freeze protection, lighting and pumping year after year. 67 Digital Wireless Controls PE40000 Series I-Wave Wireless Pool/Spa Control Intermatic’s wireless pool and spa controls utilize ground-breaking Z-wave™ technology. While some controls communicate transmission problems, Intermatic’s wireless devices allow total and uninterrupted communication between the controller and the equipment. Intermatic’s modular approach provides for added diversity and convenience. Modules are capable of working independently or within a system. Portions can be added or replaced without interfering with the original system, and each system can be designed to incorporate as many or as few features as needed to accomplish the task at hand – making Intermatic the most value added and cost-effective choice. All I-Wave Models include wireless transmitter and transceiver, two PE24VA valve actuators, five total circuits (three timed and two on demand), two-speed control, water temperature display, heater temperature control, fireman switch, freeze protection and 125 Amp breaker base. Applications • Pool/Spa combinations • Water features • Fountains PE950 Specifications Case — 26.0" (66.3 cm) high x 18.0" (45.9 cm) wide x 5.5" (14.0 cm) deep, 0.048" steel with electrostatically applied light beige finish. Knockouts: Two combination 3/4”–1”–1-1/4” and eleven combination 1/2”–3/4” knockouts on the bottom. Two 3/4”–1” combination and four combination 1/2”–3/4” knockouts on the back. Low voltage compartment has two combination 1/2”–3/4” knockouts and one 3/4” hole with a shutter bushing installed. Two combination 3/4”–1” and one combination 1/2–3/4” knockouts. One 1-3/4” x 2-3/4” knockout on the right side. Switch Rating: P1353ME – see page 70; P4243ME – see page 71 Model Mechanisms Switch Transformer Volts 60Hz Shipping Weight PE45343RC PE45343RCT1 PE45343RCT3 PE650 PE950 P1353ME and P4243ME P1353ME and P4243ME P1353ME and P4243ME Wireless Receiver Wireless Transmitter 5 - SPST 5 - SPST 5 - SPST – – None 100 Watt 300 Watt – – 120 or 208-240 120 or 208-240 120 or 208-240 – – 44.0 lbs. 51.0 lbs 56.0 lbs 5.5 lbs 5.5 lbs Complete System PE650 PE45343RC 68 WEATHERPROOF • ENERGY CONTROLS • PROFESSIONAL LIGHTING • POOL & SPA • SURGE PROTECTION • CONSUMER Salt Chlorine Generators PE25 & PE40 Series I-Pure Stand Alone Salt Chlorine Generator While traditional Salt Chlorine Generators can be difficult to manage and operate, the new I-Pure Salt Chlorine Generator takes the hassle out of sanitizing pools and spas. The I-Pure system produces more chlorine than other Salt Chlorine Generators and provides homeowners with easy-to-use, high quality sanitation at a competitive price. Designed for pools up to 25,000 gallons or 40,000 gallons, the I-Pure Stand Alone Salt Generator’s self-adjustable control dial allows users to increase or decrease chlorine production with ease. The simplified controls of the I-Pure deliver easy pool maintenance. Applications • Residential Pools • Water Features • Commercial Pools • Fountains Specifications Case — 15.0" (38.3 cm) high x 10.5" (26.8 cm) wide x 4.5" (11.4 cm) deep. Voltage: 120VAC or 240VAC (See Below) Shipping Weight: See Chart Agency Approval: ARL PE40K240V Checklist for proper operation: Salt 3000 to 4000 ppm Free Chlorine 1 to 3 ppm PH 7.2 to 7.8 Total Alkalinity 80 to 180 - adjust per calcium hardness level Stabilizer (Cyanuric Acid) 60 - 80 Nitrates 0 ppm Metals 0 ppm Phosphates 0 ppm Calcium Hardness Determine level for individual pool surface Saturation Index -0.3 to 0.3 (0 is ideal) Model PE25K120V PE25K240V PE40K120V PE40K240V Cell Features Max Gallons Volts 60 Hz Shipping Weight 25,000 25,000 40,000 40,000 120 208-240 120 208-240 22.0 lbs (9.9 kg) 22.0 lbs (9.9 kg) 22.0 lbs (9.9 kg) 22.0 lbs (9.9 kg) The I-Pure system utilizes plates that are specially coated to convert regular table salt into natural chlorine. The system uses the most advanced self-cleaning technologies, including reversed polarity, which allows the Cell to stay cleaner and last longer than other self-cleaning cells. The clear Cell also allows for easy regular inspections for calcium build-up. I-Pure Demo Kits PEDCHLR - Empty I-Pure shell only PEDCELL - Empty I-Pure cell only PE25KCELL Replacement 25,000 gallon cell only PE40KCELL Replacement 40,000 gallon cell only WEATHERPROOF • ENERGY CONTROLS • PROFESSIONAL LIGHTING • POOL & SPA • SURGE PROTECTION • CONSUMER 69 Digital Control Mechanisms P1353ME Digital Pool/Spa Mechanism Designed as part of the I-Wave system and for aftermarket and retro-fit applications, the P1353ME has the ability to program three circuits and snap into almost any Intermatic enclosure. Five pre-programmed modes of operation include single speed pump or two-speed pump and booster/cleaner pump combinations. In addition, programmed modes that include auxiliaries can control pumps up to 3HP as well as underwater, garden and/or fountain lighting. Countdown and Override features allow cycle interruptions when pool/spa service is required. All timing and protection associated with filter pump/cleaner pump combinations and two speed pumps has already been integrated into the software. Applications • Single Speed Pump Combos • Two-Speed Pump/Booster Pump Combos • Pool & Spa Lighting • Water Feature Applications • Garden & Fountain Lighting • Landscape Lighting Key Features Include P1353ME • Memory Back-Up • Heater Protection (Fireman Switch) • Three On/Off Events per Day per Circuit • Wired Remote – 133PE1484A (optional) • 120V or 240V Input • LCD Display • Freeze Protection Probe – 178PA28A (optional) Mode 1 – (Aux1, Aux2, Aux3) The time switch is a 3-circuit switch with all three switches controlling auxiliary devices. Mode 2 – (Pump High, Pump Low, Aux3) The time switch is a 2-circuit switch with the 1st & 2nd switch controlling a two-speed pump. The 3rd switch is controlling any auxiliary device. All protection associated with a two speed pump is preprogrammed into this mode. Mode 3 – (Pump, Aux2, Cleaner Pump) The time switch is a 3-circuit switch with the 1st switch controlling a single speed pump, the 2nd switch controls any auxiliary device, and the 3rd switch operates a booster/cleaner pump. All timing & protection associated with a filter pump/cleaner pump combination is preprogrammed into this mode. 133PE1484A Mode 4 – (PumpHigh, PumpLow, Cleaner Pump) The time switch is a 2-circuit switch with the 1st & 2nd switch controlling a 2-speed pump. The 3rd switch is controlling a booster/cleaner pump. All protection associated with a 2-speed pump and booster/cleaner pump combination is preprogrammed into this mode. Mode 5 – (Pump L1, Pump L2, Aux3) 178PA28A The time switch is a 2-circuit switch with the 1st & 2nd switch controlling a 240V pump, where both L1 & L2 are required to be disconnected when the pump is OFF. The 3rd switch is controlling any auxiliary device. Specifications Input Voltage – 120 Volt or 208-240 Volt, 50/60 Hz. Number of Circuits – Up to three SPST 3HP circuits. Switch Rating (each circuit) – 20 Amp Resistive, 120/240 VAC, 50/60 Hz; 20 Amp FLA @ 120 VAC, 96 Amp LRA @ 120 VAC, 50/60 Hz; 17 Amp FLA @ 240 VAC, 80 Amp LRA @ 240 VAC, 50/60 Hz; 5 Amp Tungsten, 120/240 VAC, 50/60 Hz; 5 Amp Ballast, 120/240V VAC, 50/60 Hz Shipping Weight – 3.0lbs. (1.4 kg.) Note: The P1353ME will not retro-fit into any enclosure that uses stand off posts to attach the mechanism. 70 WEATHERPROOF • ENERGY CONTROLS • PROFESSIONAL LIGHTING • POOL & SPA • SURGE PROTECTION • CONSUMER Digital Control Mechanisms P4243ME Pump/Valve Actuator Mechanism Designed as part of the I-Wave system, this electronic control mechanism, especially designed for pool/spa combinations, will snap into most Intermatic panels and enclosures in use today. Designed as a very versatile, user-friendly device, it can be combined with a number of different Intermatic controls in order to facilitate a variety of custom applications. This mechanism can handle two motor loads, up to 3 HP, switch up to 3 valve actuators, the heater thermostats and also allow the user to select pool and spa heater operation. The control options are numerous. For example, the Pool-to-Spa operation can be activated three different ways. By a remote installed count down timer, a radio receiver or a simple toggle switch. In the pool mode, any new or existing timer or manual switch may be used to control the filter pump operation. In the Spa mode, the filter pump and an additional piece of equipment can be controlled by a wired remote on the spa side (133PE1484A), by wireless remote, or by the buttons provided on the face of the mechanism. If combined with the P1353ME Digital Pool/Spa mechanism, the two units can handle all the equipment variations of a pool/spa combination, including two-speed filter pump, cleaner pump, up to three 24 volt valve actuators, two stage protected heater, jet pump, blower and lights. P4243ME Applications • Pool/Spa Combinations • Blower • Pool & Spa Lighting • Water Feature • Filter Pump • Jets • Landscape Lighting Specifications Input Voltage – 120 Volt or 208-240 Volt, 50/60 Hz. Switch Rating (each circuit) – 17 Amp resistive 120-240V, 10 Amp Tungsten – 120V, 1.5 HP – 120V, 3 HP – 240V, 60Hz Number of Circuits – Up to two DPST 3HP circuits Shipping Weight – 5 lbs (2.2 kg) 133PE1484A WEATHERPROOF • ENERGY CONTROLS • PROFESSIONAL LIGHTING • POOL & SPA • SURGE PROTECTION • CONSUMER 71 Digital Controls PE100 Series Mini PE Series Digital Pool or Spa Controls Intermatic’s Mini-PE Series Digital Controls couple the standard features of our compact T100 Series mechanical time switches with the convenience of digital automation. One of Intermatic’s latest innovations, the P1353ME allows the ability to program up to three circuits. Beyond single and two-speed pump/booster pump applications, auxiliary modes can control pumps up to 3HP as well as underwater, garden and/or fountain lighting. Countdown and override features allow cycle interruptions when pool/spa service is required. All timing and protection associated with filter pump/booster pump combos and two-speed pumps has already been integrated into the digital software. The Mini-PE Series is available in both metal and plastic enclosures and with a wired remote command, freeze probe or both. See chart below for details. PE153 Intermatic makes it simple to convert your Mini-PE Series Digital Control into a Wireless Control System. Simply install a Panel Mounted Transceiver (RC650) and Hand-Held Transceiver (PE950) to any Mini-PE Series control, which allows the system to display the status of each of the three circuits as well as pool or spa water temperature, pool or spa thermostat set point, heating status and overall communication status. Applications • Single Speed Pump/Booster Pump Combos • Water Feature Applications • Pool & Spa Lighting • Two-Speed Pump/Booster Pump Combos • Garden & Fountain Applications • Landscape Lighting Specifications PE153W PE153F Case – NEMA 3R rated for indoor-outdoor installation. 9-3/8" (23.8 cm) high, 5-1/2" (14.0 cm) wide, 3-5/8" (9.2 cm) deep in beige finish. “P” suffix models are same dimensions, except made from outdoor grade plastic. Knockouts – Combination 1/2" – 3/4" nominal knockouts, one on back and each side of case and two on bottom. Switch Rating (each circuit) – 20 Amp Resistive, 120/240 VAC, 50/60 Hz; 20 Amp FLA @ 120 VAC, 96 Amp LRA @ 120 VAC, 50/60 Hz; 17 Amp FLA @ 240 VAC, 80 Amp LRA @ 240 VAC, 50/60 Hz; 5 Amp Tungsten, 120/240 VAC, 50/60 Hz; 5 Amp Ballast, 120/240V VAC, 50/60 Hz Shipping Weight – 3.7 lbs (1.7 kg) Agency Approval – CSA/C-US Model # Description Switch Clock Supply PE153 PE153W Digital Time Clock in Metal Enclosure Digital Time Clock in Metal Enclosure with 100' Wired Remote Command Digital Time Clock in Metal Enclosure with Freeze Protection Probe Digital Time Clock in Metal Enclosure with 100' Wired Remote Command & Freeze Protection Probe Digital Time Clock in Plastic Enclosure Digital Time Clock in Plastic Enclosure with 100' Wired Remote Command Digital Time Clock in Plastic Enclosure with Freeze Protection Probe Digital Time Clock in Plastic Enclosure with 100' Wired Remote Command & Freeze Protection Probe 3 - SPST 3 - SPST 120 or 240V 120 or 240V 3 - SPST 120 or 240V 3 - SPST 120 or 240V 3 - SPST 3 - SPST 120 or 240V 120 or 240V 3 - SPST 120 or 240V 3 - SPST 120 or 240V PE153F PE153WF PE153P PE153PW PE153PF PE153PWF NOTE: See page 68 for PE650 and PE950 specifications and page 70 for P1353ME specifications PE153WF 72 WEATHERPROOF • ENERGY CONTROLS • PROFESSIONAL LIGHTING • POOL & SPA • SURGE PROTECTION • CONSUMER Digital Controls PE Series Digital Controls For pool, spa or water feature applications, the PE Series Digital Controls includes one P1353ME mechanism that controls a total of three timed circuits, including single-speed or two-speed filter pumps, cleaner/booster pumps, pool lights, spa lights and landscape lights. Intermatic makes it simple to convert your PE Series Digital Control into a Wireless Control System. Simply install a Panel Mounted Transceiver (RC650) and a Hand-Held Transceiver (PE950). Applications • Single Speed Pump/Booster Pump Combos • Water Feature Applications • Two-Speed Pump/Booster Pump Combos • Garden & Fountain Applications • Pool & Spa Lighting • Landscape Lighting PE25300 Case – 16-1/2" (41.9 cm) high x 10-7/8" (27.6 cm) wide x 4-1/4" (10.8 cm) deep, 0.048" steel with electrostatically applied light beige finish. Knockouts – One 1.09 diameter through hole, six combination 1/2"-3/4" knockouts, and three combination 3/4"-1" knockouts on the bottom. Two combination 1/2"-3/4" on the left side and one combination 3/4"-1" on the back. One knockout 1-3/4" x 2-3/4" on the right side for mounting switches or GFCI. Panel Rating – 60 Amp 120/240 V.A.C or 120/208 VAC single phase Switch Rating – P1353ME - See page 70 Agency Approval – CSA/C-US PE25300 PE35300 Case – 22" (55.9 cm) high x 14-3/4" (37.5 cm) wide x 4-1/4" (10.8 cm) deep, 0.048" steel with light beige finish. Knockouts – One 1.09 diameter through hole, six combination 1/2"-3/4" knockouts, 2 combination 3/4", 1", 1-1/4" knockouts, four 1/2" knockouts on the bottom. Two combination 1/2"-3/4" knockouts on the left side and four combination 1/2"-3/4" knockouts, two combination 3/4"-1" on the back. One knockout 1-3/4" x 23/4" on the right side for mounting switches or GFCI. Panel Rating – 80 Amp 120/240 VAC or 120/208 VAC single phase Switch Rating – P1353ME - See page 70 Agency Approval – CSA/C-US Model # Description/Mechanism Switch Clock Supply Volts 60 Hz Shipping Weight PE25300 PE35300 P1353ME P1353ME 3–SPST 3-SPST 120 or 240 120 or 240 14.0 lbs (6.3 kg) 19.0 lbs (8.6 kg) PE35300 PE1500RC Series Mini-Wave Wireless Pool/Spa Control Panels For pool/spa combinations or pool/water feature combinations, the PE1541RC controls four circuits, two PE24VA valve actuators, Wireless Panel Mounted Transceiver (PE650) and Hand-Held Transceiver (PE950), which allows the system to display the status of each of the four on-demand circuits, pool and spa water temperature, pool and spa thermostat set point, heating status and overall communication status. PE1501RC does not include actuators and is designed for pool or spa applications. PE1500RC Panel Rating – 100 Amp 120/240 VAC or 120/208 VAC single phase Switch Rating – 17A Resistive, 120/240 VAC., 50/60 Hz; 1.5 HP @ 120 VAC., 50/60 Hz; 3.0 HP @ 240 VAC., 50/60 Hz; 10 Amp Tungsten, 120/240 VAC, 50/60 Hz Shipping Weight – 24.3 lbs. (10.9 kg) Agency Approval – CSA/C-US Model # Description/Mechanism PE1541RC PE1501RC PB313E PB313E Circuits Actuators Switch Clock Supply Volts 60 Hz 4 4 2 None 4–SPST 4-SPST 120 or 240 120 or 240 PE1541RC WEATHERPROOF • ENERGY CONTROLS • PROFESSIONAL LIGHTING • POOL & SPA • SURGE PROTECTION • CONSUMER 73 Mechanical Controls T10000R Series Pool & Spa Control Centers The T10000R Series Control Centers feature an all-weather enclosure and contain one or two heavy duty timer mechanisms. In addition, they have provision to install switches or GFCI receptacle on the side and additional switches inside. The enclosure accepts any combinations of P1353ME or P4243ME or T100M or RC2000M or PF1000M Series mechanisms. Applications T10000R • Filter Pumps-Booster Pump Combinations • Filter Pump-Light Controls • Pool-Spa Combinations • Yard Lighting • Signs Specifications Case – 12" (30.5 cm) H x 12" (30.5 cm) W x 4-1/4" (10.8 cm) D, 0.048" steel with electrostatically applied light beige finish. Knockouts – Five combination 1/2"-3/4" and two combination 3/4"-1" knockouts on the bottom. One combination 1/2"-3/4" on the left side and one combination 3/4"-1" on the back. One knockout 1-3/4" x 2-3/4" on the right side for mounting switches or GFCI. Center Rating – 92 Amp per leg, 168 Amp Max. 120-240 VAC or 120-208 VAC single phase - 60 Hz Time Switch Rating – 30 Amp Resistive Inductive, Tungsten or 1000 VA pilot duty each pole 120/208/240 VAC; 2 HP (24 FLA) - 120 VAC; 5 HP (28 FLA) - 240 VAC Shipping Weight – See Table. Agency Approval – CSA/C-US T10004R Model # Description/Mechanism Switch T10000R T10101R T10004R T10404R T10604R* T12404R** Enclosure Only Two T101M One T104M Two T104M T106M & T104M T104M201 & T104M None SPST – SPST NA – DPST DPST – DPST SPDT – DPST DPST –DPST Clock Supply Volts 60 Hz NA / NA 120 /120 NA / 240 240 / 240 240 / 240 240 / 240 Shipping Weight 9.3 lbs (4.2 kg) 11.0 lbs (5.0 kg) 10.5 lbs (4.7 kg) 11.0 lbs (5.0 kg) 11.0 lbs (5.0 kg) 11.0 lbs (5.0 kg) * For 2 Speed Pump Applications. ** The heater protection switch (fireman switch) is closed when the time switch contacts are open to allow remote operation of the heater. A flow or pressure switch therefore must always be part of the heater control circuit. For additional trippers ( 1 “ON” 1 “OFF” per pack), order No. 156T1978A. For additional “OFF” trippers (25 “OFF” per pack), order No. PA115. For Stand offs for décor knockouts (4 stand-offs per pack), order No. 21T156A. T10404R 74 WEATHERPROOF • ENERGY CONTROLS • PROFESSIONAL LIGHTING • POOL & SPA • SURGE PROTECTION • CONSUMER Mechanical Controls T20000R Series 60 Amp Pool/Spa Control Panels The T20000R Series Control Panels feature an all-weather enclosure and contain a 4 circuit breaker base, an equipment grounding bar and a mechanical time switch mechanism. The circuit breaker base accepts interchangeable type breakers made by a number of different manufacturers. In addition, the enclosure has provision for installing additional switches or GFCI receptacles on the side and inside. Applications • Filter Pumps • Signs • Lights • Air Conditioners • Ventilating Systems • Heaters Specifications T21000R Case – 16-3/4" (42.6 cm) H x 8-7/8" (22.5 cm) W x 4-3/8" (11.1 cm) D. 0.048" steel with electrostatically applied light beige finish. Knockouts – Five combination 1/2"-3/4" and three 3/4" - 1" on the bottom, one combination 1/2"-3/4" on the left side, one 3/4"-1" on the back and one combination 1-3/4" x 2-3/4" knockout on the right side for mounting switches or GFCI Panel Rating – 60 Amp 120/240 VAC or 120/208 VAC; Single Phase-60 Hz Time Switch Rating – 30 Amp Resistive Inductive, Tungsten or 1000 VA pilot duty each pole 120/208/240 VAC; 2 HP (24 FLA) - 120 VAC; 5 HP (28 FLA) - 240 VAC Shipping Weight – See table. Agency Approval – CSA/C-US Model # Description/Mechanism Switch T21000R T21001R T21004R T20004R* Enclosure only T101M T104M T104M None SPST DPST DPST * T20004R has a limited availability, T21004R is the replacement model. For additional trippers ( 1 “ON” 1 “OFF” per pack ), order No. 156T1978A For additional “OFF” trippers (25 “OFF” per pack), order No. PA115 For Stand offs for décor knockouts (4 stand-offs per pack), order No. 21T156A Clock Supply Volts 60 Hz NA 120 240 240 Shipping Weight 11.2 lbs (5.0 kg) 14.0 lbs (6.3 kg) 14.0 lbs (6.3 kg) 14.0 lbs (6.3 kg) T21004R T20004R WEATHERPROOF • ENERGY CONTROLS • PROFESSIONAL LIGHTING • POOL & SPA • SURGE PROTECTION • CONSUMER 75 Mechanical Controls T30000R Series 100 Amp Pool/Spa Control Panels The T30000R Series Control Panels reduce installation costs and provide all of the electrical requirements for any pool and/or spa installation. They offer an all-in-one electrical control center which can be custom wired for a wide variety of requirements, and eliminate the need for additional junction boxes and service panels. The enclosure accepts any combinations of P1353ME or P4243ME or T100M or RC2000M or PF1000M Series mechanisms Applications T30000R5 • Filter Pumps • Security Systems • Booster Pumps • Fountains • Heating Systems • Sprinkler Systems • Lights • Valve Actuators • Cleaning Systems • Yard Lights Specifications Case – 16-1/2" (41.9 cm) H x 10-7/8" (27.6 cm) W x 4-1/4" (10.8 cm) D, 0.048" steel with electrostatically applied beige finish Knockouts – Two 1/2", three combination 1/2"-3/4", and two combination 3/4"-1" knockouts on the bottom. Four 1/2", three combination 1/2"-3/4" on the back. One combination 3/4"-1" on the left side. One 1-3/4" x 23/4" knockout on the right side for mounting switches and GFCI. Panel Rating – 100 Amp., 120-240 VAC or 120-208 VAC single phase - 60Hz. Timer Switch Rating – 30 Amp Resistive Inductive, Tungsten or 1000 VA pilot duty each pole 120/208/240 VAC; 2 HP (24 FLA) - 120 VAC; 5 HP (28 FLA) - 240 VAC Shipping Weight – See table. Agency Approval – CSA/C-US T30004R Model # Description/Mechanism Switch T30000R5 T30004R T30401R T30404R T30604R T32404R Enclosure Only One T104M T104M & T101M Two T104M T106M & T104M T104M201 & T104M None None / SPST DPST / SPST DPST / DPST SPDT / DPST DPST / DPST Clock Supply Volts 60 Hz NA / NA NA / 240 240 / 120 240 / 240 240 / 240 240 / 240 Shipping Weight 18.6 lbs (8.4 kg) 18.6 lbs (8.4 kg) 18.6 lbs (8.4 kg) 18.6 lbs (8.4 kg) 18.6 lbs (8.4 kg) 18.6 lbs (8.4 kg) * The heater protection switch (fireman switch) is closed when the time switch contacts are open to allow remote operation of the heater. A flow or pressure switch therefore must always be part of the heater control circuit. For additional trippers ( 1 “ON” 1 “OFF” per pack), order No. 156T1978A. For additional “OFF” trippers (25 “OFF” per pack), order No. PA115. For Stand offs for décor knockouts (4 stand-offs per pack), order No. 21T156A. T32404R 76 WEATHERPROOF • ENERGY CONTROLS • PROFESSIONAL LIGHTING • POOL & SPA • SURGE PROTECTION • CONSUMER Quality Pool & Spa Controls T40000R Series 125 Amp Pool/Spa Control Panels The T40000R Series Control Panels reduce installation costs and provide all of the electrical requirements for any pool and/or spa installation. They offer an all-in one electrical control center which can be custom wired for a wide variety of requirements, and eliminate the need for additional junction boxes and service panels. The enclosure accepts any combinations of P1353ME or P4243ME or T100M or RC2000M or PF1000M Series mechanisms. T40000R Applications • Filter Pumps • Security Systems • Booster Pumps • Fountains • Heating Systems • Sprinkler Systems • Lights • Yard Lights • Cleaning Systems Specifications Case – 20-3/4" (52.7 cm) high x 12-3/4" (32.4 cm) wide x 4-1/4" (10.8 cm) deep, 0.048" steel with electrostatically applied light beige finish Knockouts – Seven combination 1/2"-3/4" and three combination 3/4"-1" knockouts on the bottom. Five combination 1/2"-3/4" on the left side. One 1-3/4" x 2-3/4" knockout on the right side for mounting switches and GFCI Panel Rating – 1 Timer Switch Rating – 30 Amp Resistive Inductive, Tungsten or 1000 VA pilot duty each pole 120/208/240 VAC; 2 HP (24 FLA) - 120 VAC; 5 HP (28 FLA) - 240 VAC Shipping Weight – See table. Agency Approval – CSA/C-US Model # Description/Mechanism Switch T40000R T40004R T40404R Enclosure Only One T104M Two T104M None DPST DPST Clock Supply Volts 60 Hz NA NA / 240 240 / 240 Shipping Weight T40004R T40404R 16.0 lbs (7.2 kg) 20.5 lbs (9.2 kg) 21.2 lbs (9.5 kg) For additional trippers ( 1 “ON” 1 “OFF” per pack ), order No. 156T1978A. For additional “OFF” trippers (25 “OFF” per pack), order NO. PA115. For additional stand-offs for décor knockouts (4 stand-offs per pack), order No. 21T156A. T40000R Series 100 Amp Specialty Control Panels T40000R4 These specialty Control Panels are the same as the T40000R Series, except they have been designed for specialty applications. Models include a factory installed GFCI, or stainless steel panel for high corrosive environments or an inside wiring compartment for two devices. These enclosures accept any combinations of T100M, P1353ME, P4243ME or T100M or RC2000M or PF1000M Series mechanisms. Applications Specifications Same as above. Case, Knockouts, Timer Switch Rating & Agency Approval – Same as above Panel Rating – 115 Amp. 120-240 VAC or 120-208 VAC single phase - 60 Hz. Shipping Weight – See table. Model # Description/Mechanism Switch T40000R4* T40004RSS** T40004R5 T40404R5 Inside Compartment One T104M One T104M & GFCI Installed Two T104M & GFCI Installed None / None None / DPST None / DPST DPST / DPST T40004RSS Clock Supply Volts 60 Hz Shipping Weight NA / NA NA / 240 NA / 240 240 / 240 19.4 lbs (8.7 kg) 20.5 lbs (9.2 kg) 21.6 lbs (9.7 kg) 24.6 lbs (11.0 kg) * Enclosure only with inside wiring compartment for twist-lock receptacle and GFCI. ** Stainless Steel Enclosure. For additional trippers ( 1 “ON” 1 “OFF” per pack ), order No. 156T1978A. For additional “OFF” trippers (25 “OFF” per pack), order NO. PA115. For additional stand-offs for décor knockouts (4 stand-offs per pack), order No. 21T156A. T40004R5 WEATHERPROOF • ENERGY CONTROLS • PROFESSIONAL LIGHTING • POOL & SPA • SURGE PROTECTION • CONSUMER 77 Safety Transformers T10000RT, T40000RT & PE45343RCT Series Pool Panels with Transformer These Panels with Transformer offer an all-in-one, easy to wire and extremely cost effective electrical control center for any pool or spa installation. Inside the enclosure are the time switch, the transformer and other components needed for the completion of this installation. The T40000RT Series panels will accept additional Intermatic mechanisms and/or components. The PE45343RCT Series includes all the features of the PE Series Digital Controls plus two PE24VA valve actuators, Wireless Panel Mounted Transceiver (PE950), which allows the system to display the status of each of the five circuits (3 timed and 2 on demand), pool and spa water temperature, pool and spa thermostat set point, heating status and overall communication status. T10004RT1 Applications • Filter Pumps • Low Voltage Outdoor Lighting • Blowers • Fountains • Low Voltage Pool/Spa Lighting Specifications T10000RT Series Case – 12" (30.5 cm) H x 12" (30.5 cm) W x 4-1/4" (10.8 cm) D, 0.048" steel with electrostatically applied light beige finish Knockouts – Five combination 1/2"-3/4" and two combination 3/4"-1" knockouts on the bottom. One combination 1/2"-3/4" on the left side and one combination 3/4"-1" on the back. One knockout 1-3/4" x 2-3/4" on the right side for mounting switches or GFCI Center Rating – 92 Amp per leg, 168 Amp Max. 120-240 VAC or 120-208 VAC single phase - 60 Hz. T40004RT3 T40000RT Series Case – 20-3/4" (52.7 cm) high x 12-3/4" (32.4 cm) wide x 4-1/4" (10.8 cm) deep, 0.048" steel with electrostatically applied light beige finish. Knockouts – Seven combination 1/2"-3/4" and three combination 3/4"-1" knockouts on the bottom. Five combination 1/2"-3/4" on the left side. One 1-3/4" x 2-3/4" knockout on the right side for mounting switches and GFCI. Panel Rating – T40000RT Series - 100 Amp 120-240 VAC or 120-208 VAC single phase - 60 HZ Timer Switch Rating – 30 Amp Resistive Inductive, Tungsten or 1000 VA pilot duty each pole 120/208/240 VAC; 2 HP (24 FLA) - 120 VAC; 5 HP (28 FLA) - 240 VAC PE45343RCT Series Case – 12" (30.5 cm) H x 12" (30.5 cm) W x 4-1/4" (10.8 cm) D, 0.048" steel with electrostatically applied light beige finish Knockouts – Five combination 1/2"-3/4" and two combination 3/4"-1" knockouts on the bottom. One combination 1/2"-3/4" on the left side and one combination 3/4"-1" on the back. One knockout 1-3/4" x 2-3/4" on the right side for mounting switches or GFCI Panel Rating – T40000RT Series - 100 Amp 120-240 VAC or 120-208 VAC single phase - 60 HZ Agency Approval – CSA/C-US Model # T10004RT1 T10004RT3 T40003RT3 T40004RT1 T40004RT3 PE45343RCT1 PE45343RCT3 PE45343RCT3 78 Transformer Input 60 Hz Output Mechanism Shipping Weight 100 Watt 300 Watt 300 Watt 100 Watt 300 Watt 100 Watt 300 Watt 120V, 1 Amp 120V, 3 Amp 120V, 3 Amp 120V, 1 Amp 120V, 3 Amp 120V, 1 Amp 120V, 3 Amp 12V, 13V, 12V, 13V, 14V 12V, 13V, 14V 12V, 13V, 12V, 13V, 14V 12V, 13V 12V, 13V, 14V T104M T104M T103M T104M T104M P1353ME & P4243ME P1353ME & P4243ME 14.0 lbs (6.3 kg) 20.0 lbs (9.0 kg) 32.0 lbs (14.4 kg) 26.0 lbs (11.7 kg) 32.0 lbs (14.4 kg) 56.0 lbs (25.2 kg) 61.0 lbs (27.5 kg) For additional trippers ( 1 “ON” 1 “OFF” per pack ), order No. 156T1978A. For additional “OFF” trippers (25 “OFF” per pack), order No. PA115. For stand-offs for décor knockouts (4 stand-offs per pack), order No. 21T156A.Note: See Page 29 for a detailed list of T100M replacement mechanisms and page 16 for PE650 and PE950 specifications WEATHERPROOF • ENERGY CONTROLS • PROFESSIONAL LIGHTING • POOL & SPA • SURGE PROTECTION • CONSUMER Safety Transformers PX100, PX300 & PX600 SeriesSafety Transformers These Safety Transformers are specifically designed to supply 12 volts to pool/spa lights, submersible fixtures and outdoor garden lights. A grounded shield between the primary and secondary windings assures safe operation and the built-in circuit protection will disconnect power to the transformer in case of defect or overload. Applications • Pool Lights • Spa Lights • Garden Lights • Fountain Lights PX100 Specifications - PX100/S, PX300/S Enclosure – 7.25" (19.4 cm) H x 5.25" (13.3 cm) W x 4.5" (11.4 cm) D. Stainless steel or steel with electrostatically applied light beige finish. Mounting brackets top and bottom. Knockouts – Total of ten combination 1/2”-3/4” knockouts, (2) right side, (2) left side, (2) back, (4) bottom. Electrical Rating – See table. Shipping Weight – See table. PX100S Specifications – PX600/S Enclosure – 10" (25.4 cm) high x 10" (25.4 cm) wide x 5" (12.7 cm) deep. Stainless steel or steel with electrostatically applied light beige finish. Mounting brackets top and bottom. Knockouts – Two combination 1/2"-3/4", and 4 combination 3/4"-1" knockouts on the bottom. Total of six combination 1/2"-3/4" knockouts, (2) right side, (2) left side, (2) back. Electrical Rating – See table. Shipping Weight – See table. Model # Description Input Output Shipping Weight PX100 PX100S PX300 PX300S PX600 PX600S 100 Watt Beige Steel Enclosure 100 Watt Stainless Steel Enclosure 300 Watt Beige Steel Enclosure 300 Watt Stainless Steel Enclosure 600 Watt Beige Steel Enclosure 600 Watt Stainless Steel Enclosure 120V, 1AMP 120V, 1AMP 120V, 3AMP 120V, 3AMP 120V, 6AMP 120V, 6AMP 12 or 13V 12 or 13V 12,13 or 14V 12,13 or 14V 12,13 or 14V 12,13 or 14V 7.0 lbs (3.2 kg) 7.0 lbs (3.2 kg) 13.0 lbs (5.9 kg) 13.0 lbs (5.9 kg) 26.0 lbs (11.7 kg) 26.0 lbs (11.7 kg) PX300 PX300S PX600 PX600S WEATHERPROOF • ENERGY CONTROLS • PROFESSIONAL LIGHTING • POOL & SPA • SURGE PROTECTION • CONSUMER 79 Freeze Protection Controls PF1100 Series Single Circuit Freeze Protection Controls These Freeze Protection Controls are designed to protect the pool and spa equipment and plumbing against freeze damage. They turn the pump and the heater ON vwhen the outdoor temperature drops below the temperature set by the user-adjustable thermostat. Models without timer connect to a timing or switching device and together, they control operation of the equipment as well as protect it against freeze damage. Models with timer provide both automation and protection for the equipment. PF1102M APPLICATIONS • Filter Pumps • Waterfalls • Filter Pump/Booster Pump Combinations • Water Features SPECIFICATIONS PF1102 CASE - 0.034 inch drawn steel, electrostatically coated, beige color. Hasp, with hole for lock, holds permanently attached side-hinged door closed. 9-3/8" (23.8 cm) high x 5-1/4" (14.0 cm) wide x 3-5/8" (9.2 cm) deep. KNOCKOUTS - 1/2" - 3/4" combination knockouts, one back, one on each side, two bottom. THERMOSTAT RANGE - 45°F - 32°F with 5 degrees differential. ELECTRICAL RATING - See table SHIPPING WEIGHT - See table. AGENCY APPROVAL - CSA/C-US Model # Description Input PF1102 PF1102M PF1102T PF1102MT PF1103 PF1103M PF1103T PF1103MT Thermostat only. For 240V installation. Same as above, mechanism only. Timer with thermostat. For 240V installation. Same as above, mechanism only. Thermostat only. For 120/240V installation. Same as above, mechanism only. Timer with thermostat. For 120/240V installation Same as above, mechanism only. 240V 240V 240V 240V 120/240V* 120/240V* 120/240V* 120/240V* Rating H.P. 3 3 3 3 1.5/3 1.5/3 1.5/3 1.5/3 Shipping Weight 3.7 lbs (1.7 kg) 2.0 lbs (0.9 kg) 4.5 lbs (2.0 kg) 2.5 lbs (1.1 kg) 3.7 lbs (1.7 kg) 2.0 lbs (0.9 kg) 4.5 lbs (2.0 kg) 2.5 lbs (1.1 kg) * Neutral must be installed. PF1103MT PF1103T 80 WEATHERPROOF • ENERGY CONTROLS • PROFESSIONAL LIGHTING • POOL & SPA • SURGE PROTECTION • CONSUMER Freeze Protection Controls PF1100 & PF1200 Series Multi Circuit Freeze Protection Control Centers & Panels These heavy-duty Freeze Protection Controls are designed specifically for pools requiring one or two time switches and protect the pool and spa equipment and plumbing against freeze damage. They turn the pump and the heater ON when the outdoor temperature drops below the temperature set by the user-adjustable thermostat. In addition, they have a provision to install switches inside or GFCI receptacle on the side of enclosure. Applications • Filter Pumps • Combinations • Filter Pump-Booster Pump • Pool-Spa Combinations • Fountains PF1112T Specifications PF1112T, PF1202T Case – 12" (30.5 cm) H x 12" (30.5 cm) W x 4-1/4" (10.8 cm) D, 0.048" steel with electrostatically applied light beige finish. Knockouts – Five combination 1/2"-3/4" and two combination 3/4"-1" knockouts on the bottom. One combination 1/2"-3/4" on the left side and one combination 3/4"-1" on the back. One knockout 1-3/4" x 2-3/4" on the right side for mounting switches or GFCI Center Rating – 92 Amp per leg, 168 Amp Max. 120-240 VAC or 120-240VAC single phase - 60 Hz. Electrical Rating – See table. Thermostat Range – 44°F - 32°F with 5 degrees differential. Shipping Weight – See table. Agency Approval – CSA/C-US PF1222TB Case – 16-1/2" (41.9 cm) H x 10-7/8" (27.6 cm) W x 4-1/4" (10.8 cm) D, 0.048" steel with electrostatically applied beige finish. Knockouts – Two 1/2", three combination 1/2"-3/4", and two combination 3/4"-1" knockouts on the bottom. Four 1/2", three combination 1/2"-3/4" on the back. One combination 3/4"-1" on the left side. One 1-3/4" x 23/4" knockout on the right side for mounting switches and GFCI. Panel Rating – 100 Amp max., 120-240 VAC or 120-208 VAC single phase - 60 Hz. Electrical Rating – See table. Thermostat Range – 44°F - 32°F with 5 degrees differential. Shipping Weight – See table. Agency Approval – CSA/C-US Model # Description PF1112T PF1202T PF1222TB For pools requiring one time switch For pools with cleaner, requiring two time switches Same as a PF1202T with 4/8 breaker base and heater protection Electrical Input 240V 240V 240V PF1202T Rating HP Shipping Weight 3 3 3 8.0 lbs (3.6 kg) 10.0 lbs (4.5 kg) 17.0 lbs (7.7 kg) For additional trippers ( 1 “ON” 1 “OFF” per pack ), order No. 156T1978A. For additional “OFF” trippers (25 “OFF” per pack), order NO. PA115. For additional stand-offs for décor knockouts (4 stand-offs per pack), order No. 21T156A. PF1222TB WEATHERPROOF • ENERGY CONTROLS • PROFESSIONAL LIGHTING • POOL & SPA • SURGE PROTECTION • CONSUMER 81 Air Operated Controls Air Operated Pool/Spa & Pool-to-Spa Controls This line of Air Operated Controls is specially designed to control pool/spa combinations economically and reliably for up to 100 ft. away from the equipment. Everything needed to control the filter pump, valves, heater thermostat, booster pump, blower or lights is included in a single package and can be installed in less than two hours. A number of accessories are available to enhance the control capacity of these units. Comes complete with two PE24VA 24-Volt valve actuators. Applications • Pool/Spa Combinations • Water Features Specifications RC2403RT RC2163E Case – 0.048" steel with electrostatically applied light beige finish. See table for nominal dimensions. Maximum Range – 100 ft. (The actual distance between the control and air button depends on the amount of displaced air, the inside diameter of the air hose and other factors beyond the control of the manufacturer.) Timer – 24 Hour Electronic. Specifications/Features RC2163E RC2163FE RC2263E RC2403RT Voltage Remote Command Filter Pump Timer Controlled in Pool Mode Single Speed Only (HP) Single or Two Speed (HP) Heater Control (Single or Two Stage) Number of Valve Actuator Connections Heater Protection (Optional) Blower Independent Circuit (DPST 30A, 3HP-240V) Standard Enclosure (In) Number of Breaker Space Shipping Weight (lbs) Reference Picture 120/240 1-Air Y 3 HP NA Y 3 Y NO NO 12.9 x 10.9 x 4.3 NA 20.0 (9.0 kg) RC2163E 120/240 Any Switch* Y 3 HP NA Y 3 Y NO NO 12.9 x 10.9 x 4.3 NA 20.0 (9.0 kg) RC2163E 120/240 1-Air Y NA 2 HP Y 3 NO Y NO 12.9 x 10.9 x 4.3 NA 23.7 (10.7 kg) RC2163E 120/240 2-Air Y NA 2 HP NO 0 NO Y Y 12.9 x 10.9 x 4.3 NA 19.0 (8.6 kg) RC2163E *Can use spring wound timer, toggle switch or remote control with transmitter to operate equipment Specifications/Features RC2163BE RC2163BFE RC2263BE Voltage Remote Command Filter Pump Timer Controlled in Pool Mode Single Speed Only (HP) Single or Two Speed (HP) Heater Control (Single or Two Stage) Number of Valve Actuator Connections Heater Protection (Optional) Blower Independent Circuit (DPST 30A, 3HP-240V) Standard Enclosure (In) Number of Breaker Space Shipping Weight (lbs) Reference Picture 120/240 1-Air Y 3 HP NA Y 3 Y NO NO 16.8 x 10.9 x 4.3 8/16 24.3 (10.9 kg) RC2263BE 120/240 Any Switch* Y 3 HP NA Y 3 Y NO NO 16.8 x 10.9 x 4.3 8/16 24.3 (10.9 kg) RC2263BE 120/240 1-Air Y NA 2 HP Y 3 NO Y NO 16.8 x 10.9 x 4.3 8/16 28.0 (12.6 kg) RC2263BE RC2263BE 82 WEATHERPROOF • ENERGY CONTROLS • PROFESSIONAL LIGHTING • POOL & SPA • SURGE PROTECTION • CONSUMER Electronic Time Switches P1000 & P7000 Series Electronic Time Switches and Mechanisms This line of electronic time switches in safety enclosures are specially suited for applications where a need to turn equipment up to 8 ON and OFF cycles daily, and where the automatic operation of the equipment requires occasional override by someone other than a qualified service professional. Electronic technology allows upto-the-minute programming accuracy. The unique “door within the door” provides safe access to the timer control buttons, but prevents entry into the wiring compartment. Light indicator illuminates when timer is in ON position. An override feature is provided to allow pool service without interruption of ON-OFF settings. Select feature allows timer to be continuously ON, OFF or in Auto mode. The addition of a radio receiver (Model P1203FR) provides a 2nd circuit for any other load (light, blower etc.) requiring control from a remote location. Typical application for the clock circuit would be the pool pump, and a pool light for the radio circuit. In case of power failure, a replaceable battery preserves programming for up to three years. P1102ME Applications • Filter pumps • Pool/Spa lights • Water Features • Fountains Specifications Case – All plastic NEMA 3R rated for indoor-outdoor installation. 9-3/8" (23.9 cm) H, 5-1/2" (14.0 cm) W, 3-5/8" (9.2 cm) D in beige finish. Knockouts – Combination 1/2" - 3/4" nominal knockouts, (1) on back and each side of case, and (2) on bottom. Rating – P1102FE - 3.0 HP @ 240V, 30 Amp resistive; P1203FR - 1.5 HP @ 120V, 3.0 HP @ 240V, 30 Amp resistive; Radio Circuit - 15 Amp resistive, 10 Amp Tungsten, 1 HP motor load - 120 VAC Shipping Weight - 3.75 lbs (1.7 kg) Agency Approval – CSA/C-US P1102FE Model Number Description Switch P1102ME P1103ME 24-Hour Electronic Mechanism Only 24-Hour Electronic Mechanism Only One DPST One DPST P7101ME P7102ME P7103ME 7-Day Electronic Mechanism Only 7-Day Electronic Mechanism Only 7-Day Electronic Mechanism Only One DPST One DPST One DPST P1102FE P1103FE 24-Hour Electronic Time Switch 24-Hour Electronic Time Switch One DPST One DPST P1203FR 24-Hour Electronic Time Switch Radio Receiver Module One DPST One SPST Supply Voltage 50/60 Hz 240V only clock & load 120V for clock 120V or 240V only clock & load 120V only clock & load 240V only clock & load 120V for clock 120V or 240V only clock & load 240V only clock & load 120V for clock 120V or 240V only clock & load 3.0 HP - 208-240V only clock & load 120V only receiver & load P1203FR WEATHERPROOF • ENERGY CONTROLS • PROFESSIONAL LIGHTING • POOL & SPA • SURGE PROTECTION • CONSUMER 83 Radio Remote Controls RC600 & RC900 Outdoor Radio Remote Controls These Modular Radio Receivers are one half of a two part remote control system. They operate as ordinary ON/OFF switches but they also respond to the signals of a hand held transmitter — the other half of the system. The modules are designed for indoor or outdoor use, and can handle a variety of switching applications, typical around the house or farm. By the push of a button on the face of the transmitter, the user is able to turn ON-OFF the connected load (lights, pump, etc.) from any remote location, inside or outside of the house, safely and conveniently. In addition, a single transmitter can operate up to three receivers and is able to “teach” each module a different code (Transmitter model RC939 sold separately). Applications RC613R • Pool/Spa Pumps, Lights and Heaters • Fountain Pumps • Outdoor Lighting • Motorized Valves • Air Blowers • Signs • Motorized Gates Specifications Enclosure – Beige outdoor grade plastic. Maximum Range – 100 ft. See transmitter model RC939 for details. Model # Description RC613 Electrical Rating Receiver with ON/OFF Button 15 Amp Resistive, 10 Amp (1200 W) Tungsten, 1 HP, Motor Load - 120 V RC613L RC613 with (3) 36" Long Leads Same as RC613 RC613R Heavy Duty Receiver Module 30 Amp Resistive, 120/240 V 12.5 Amp (1500 W), 1.5 HP - 140 V 1.5 HP - 140 V, 3 HP - 240 V, Double Pole, Single Throw Contacts RC615 Timer Interface Module Same as RC613 without Manual Button Size Shipping Weight 4-1/2" H (11.4 cm) 3" W (7.6 cm), 1-1/4" D (4.0 cm) Same as RC613 7-3/4" H (19.7 cm) 4" W (10.7 cm) 3-1/2" D (8.9 cm) 0.5 lbs (0.2 kg) 0.7 lbs (0.3 kg) 1.4 lbs (0.6 kg) Same as RC613 0.5 lbs (0.2 kg) RC613L Hand Held Radio Transmitter This hand held radio transmitter operates the shared equipment of a pool/spa combination by the touch of a button. In addition, more buttons are available on the transmitter to turn ON-OFF a booster pump, a blower and lights. Applications • Pool-Spa Combinations • Water Features Specifications Enclosure – Beige plastic, 4-3/8" (11.1 cm) H, 2-3/4" (7.0 cm) W and 1" (2.5 cm) D. Model # Description Range* Battery Shipping Weight RC939 3 Channel Radio Transmitter 100 ft. 9V Transistor type 0.5 lbs (0.2 kg) * The range is 100 feet but depends on many factors like the age of the battery, proximity of large metal objects, the location of the receiver and environmental conditions at the time of transmission. RC939 84 WEATHERPROOF • ENERGY CONTROLS • PROFESSIONAL LIGHTING • POOL & SPA • SURGE PROTECTION • CONSUMER Portable Outdoor Timers P1200 Series Two-Circuit Portable Outdoor Timer These Portable Two-circuit Above Ground Pool Timers incorporate a plug in for a timed circuit (normally used for a pool pump) and a plug in for a live circuit (typically used for a pool light). GFCI protected circuits and a three-prong grounded plug for the time switch supply are also built-in. Applications • Above ground pool pumps • Above ground pool lights P1261P Specifications Case - NEMA 3R rated for indoor-outdoor installation. 9-3/8” (23.8 cm) high x 5-1/2” (14.0 cm) wide x 3-5/8” (9.2 cm) deep Knockouts - Combination 1/2” - 3/4” nominal knockouts, one on the back and each side of case, two pre-cut on bottom Timer - 24 hour with 23-1/2 hour maximum ON time. Two ON, two OFF trippers - standard. Dial will accept up to 12 sets of trippers. Shipping Weight - 2.8 lbs. (1.3kg) Model Description Electrical Plug & Receptacle P1261P PB913N84 Timer 5-15 P1261PE PB313E Electronic Timer 15 Amp (1800 W), Resistive or Tungsten 1 HP, 15 FLA (96 LRA) Motor Load 15 Amp (1800 W), Resistive or Tungsten 1 HP, 15 FLA (96 LRA) Motor Load P1261PE 5-15 For additional trippers ( 2 “ON” 2 “ OFF” per pack ), order No. 156PB10398A P1100 Series Portable Outdoor Timers – Heavy Duty Outdoor Timers These Portable Outdoor Timers are specially designed to control the filter pump of a portable pool or spa, but they can also be used to turn ON and OFF (in off-season) outdoor decoration, engine block heaters and other appliances, indoors or outdoors. P1101 Applications • Filter Pumps • Signs • Engine Block Heaters • Air Conditioners • Lights • Fans P1121 Specifications Case – Outdoor grade plastic. 5" (12.7 cm) H x 5-1/2" (13.97 cm) W x 3-3/4" (9.52 cm) D. Cord – 3 wire, outdoor grade, 22" long. Timer – 24 hour with 23-1/2 hour maximum ON time. Two ON, two OFF trippers - standard. Dial will accept up to 12 sets of trippers. Shipping Weight – 1.7 lbs (0.7 kg) Model # Description Electrical P1101 Timer P1121 Timer P1131 Heavy-Duty Timer with Twist-Lock Plug & Receptacle Safety Timer with Ground Fault Circuit Protection 15 Amp (1800 W), Resistive or Tungsten 1 HP Air Conditioner, 15 FLA (96 LRA), Motor Load 15 Amp (1800 W), Resistive or Tungsten 1 HP Air Conditioner, 15 FLA (96 LRA), Motor Load Resistive, 1 HP, 16 FLA (96 LRA) Motor Load 5-15 5L-20 15 Amp (1800 W) Resistive, Tungsten 15 FLA (90 LRA) Motor 5-15 P1161 Plug & Receptacle 5-15 P1131 P1161 For additional trippers ( 2 “ON” 2 “ OFF” per pack ), order No. 156PB10398A WEATHERPROOF • ENERGY CONTROLS • PROFESSIONAL LIGHTING • POOL & SPA • SURGE PROTECTION • CONSUMER 85 Pool/Spa Accessories PJB Series Pool/Spa Junction Box & Mounting Bracket PJB4175 PJB2175 These polymeric, water tight, multi-fixture Junction Boxes are especially designed for pools, pool-spa combinations and landscape applications. The PJB4175 provides safe and reliable connection for up to four lights. While the PJB2175 supports up to two lights. They will accommodate flexible cords from #16-3 up to #12-3 and #10-3 in any combination and non-metallic conduits from 1/2 to 1 inch, including one for supply conductor feed. An optional wall/post mounting bracket is also available. Applications • Pool Lights • Spa Lights • Landscape Lights Specifications Case – Outdoor grade plastic. PJB4175 - 7.5" L x 4.75" W x 5.0" D. PJB2175 - 7.0" L x 3.0" W x 4.0" D PA114 Model # Description PJB2175 PJB4175 PA114 Pool/Spa Light Junction Box Pool/Spa Light Junction Box Wall/Post Mounting Bracket Light Connection Case Qty. Shipping Weight 2 4 — 24 12 10 19.2 lbs (8.6 kg) 13.2 lbs (6.0 kg) 5lbs (2.3 kg) PAV Series Maintenance Free Water Valves Intermatic’s Maintenance Free Water Valves have been designed to provide reliable control of water flow to pools, spas, solar collectors, cleaners and water features. These 2-way and 3-way valves have excellent flow characteristics while maintaining back pressure. Manufactured with Intermatic’s high quality standards, the PAV Series Water Valves offer long maintenance free performance PAV320 Applications • Pools • Spas • Fountains • Water Features PAV220C Standard Features • Teflon-coated diverter requires no lubrication and ensures maintenance free performance • Innovative field adjustable stop ensures precise valve positioning • 1-1/2” valves fit 1-1/2” and 2” plumbing, 2” plumbing, 2” valves fit 2” and 2-1/2” plumbing • Available in standard PVC and high temperature CPVC Model For maximum convenience in pool/spa automation, PAV Series water valves can be used in conjunction with Intermatic PE24VA valve actuators. 86 PAV215 PAV215C PAV220 PAV220C PAV315 PAV315C PAV320 PAV320C Port Size Configuration Material Shipping Weight Each 1-1/2” 1-1/2” 2” 2” 1-1/2” 1-1/2” 2” 2” 2-WAY 2-WAY 2-WAY 2-WAY 3-WAY 3-WAY 3-WAY 3-WAY PVC CPVC PVC CPVC PVC CPVC PVC CPVC 1.5 lbs (0.6 kg) 1.5 lbs (0.6 kg) 1.6 lbs (0.7 kg) 1.6 lbs (0.7 kg) 1.5 lbs (0.6 kg) 1.5 lbs (0.6 kg) 1.6 lbs (0.7 kg) 1.6 lbs (0.7 kg) Model # Description Voltage Shipping Weight Each PE24VA Valve Actuator 24 VAC 3.5 lbs (2.2 kg) WEATHERPROOF • ENERGY CONTROLS • PROFESSIONAL LIGHTING • POOL & SPA • SURGE PROTECTION • CONSUMER Setting a New Standard for Protection The same quality and coverage you’ve come to expect from Intermatic controls can also be found in a complete line of panel-mount and point-of-use surge protection — from high current capacity industrial models to residential models, with integrated phone and coax protection. On average, the typical home or business gets hit with more than 2,000 electrical surges annually, costing home and business owners more than $26 billion dollars. As more and more homes begin housing more elaborate home theater and entertainment systems, home offices and other appliances, it is becoming increasingly important to protect all electronic investments from transient voltage or “bad power.” 87 Why Every Facility Needs Surge Protection 1.0 V(t)/Vp Electrical disturbances and downtime cost North American Companies more than $26 billion every year. Every process within your building is controlled by electrical and electronic components which all require surge protection to function reliably. 0.8 RISE TIME = 1.2 s 0.6 DURATION = 50 s 0.4 0.2 0.0 0 20 40 60 80 TIME .s 100 Voltage Waveform ANSI/IEEE has defined common disturbances which occur in modern facilities per the waveforms to the left. Depending on the proximity of the equipment to your power entry points, the severity increases. As the transient event propagates throughout your building, it degrades your electronic components by stressing them with excess voltage and current. Every modern facility is a strong candidate for protection. Intermatic has a broad line of Service Entrance, Panelboard and Point-of-Use Protection to select from. 1.0 l(t)/lp 0.8 Service Entrance, Panelboard and Point-of-Use surge protection can be found in the following types of facilities and installations: FRONT TIME = 8 s 0.6 DURATION = 20 s 0.4 0.2 0 0.0 0 10 20 30 40 TIME .s 50 Current Waveform 1.0 • Manufacturing • Healthcare/Medical • Education/University • Data Centers • Telecom/Cell Sites • Utility • Correctional • Military Installations • Airports • Broadcast Studios • Financial Institutions • Retail • General Office • Semiconductor Fabrication • Wastewater Facilities • Restaurants • Entertainment Facilities RISE TIME = 0.5 s V(t)/Vp 10 s 0.6 Virtually all devices which are powered by electricity are vulnerable. Surge Suppression is required for protection of the following types of systems: 0.4 0.2 -0.0 1 -0.2 -0.4 -0.6 -0.8 -1.0 -1.2 0 10 20 TIME .s 30 100 kHz Ringwave System Voltage The wiring diagrams characterize common voltage configurations available for the products. Refer to individual product pages for models available in below configurations. Match the voltage configuration below with your voltage configuration at your Service Entrance, Distribution Panel or Panelboard location where you want protection. • Computer/Peripherals • Network Servers/ Routers/Modems • Telecom Equipment • Variable Frequency Drives • Lighting Ballasts • HVAC Controls • Fire Alarm Systems • Security Systems • Lighting Control and Dimming Systems • Automatic Test Equipment • Wafer Fabrication Equipment • Uninterruptible Power Supplies • Bar Code Scanning Equipment • Programmable Logic Controllers • CNC Machines • Pumps, motors and related equipment which has electronic controls or starters Surge Suppression Definitions Surge Current Capacity is the rated surge current that a design will withstand based on the standard 8 x 20 microsecond current waveform. Nema LS-1 states that this should be given for each mode of a surge protection device, since devices can have different components in each mode. Modes of Protection are the coupling paths that exist in a single or three phase system. In a three phase wye system there are 10 potential modes where a transient can be coupled: L1 to Neutral L3 to Neutral L3 to L1 120/208 Volt 120/240 Volt 120 Volt Three Phase Wye Single Phase Single Phase 2 Wire plus Ground 3 Wire plus Ground 4 Wire plus Ground (split phase) L1 to Ground L3 to Ground Neutral to Ground L2 to Neutral L1 to L2 L2 to Ground L2 to L3 In a three phase delta system there are six potential modes where a transient can be coupled: L1 to Ground L1 to L2 L2 to Ground L2 to L3 L3 to Ground L3 to L1 All modes must have suppression components coupled between them in order to be 100% effective. 120/240 Volt 240 Volt 277/480 Volt Three Phase HLD Three Phase Delta Three Phase Wye (High Leg Delta) 3 Wire plus Ground 4 Wire plus Ground 4 Wire plus Ground MCOV (Maximum Continuous Operating Voltage) is the maximum steady state rms voltage at which the unit can safely operate.The recommended MCOV is 115% of nominal voltage for all voltage configurations. EMI/RFI Noise Attenuation is a way to rate filter performance over a range of specific frequencies. IEEE characterizes line noise as less than two times peak voltage. Line noise can be somewhat attenuated by the capacitance found in MOVs, but typically requires the addition of capacitors to increase effectiveness. EMI/RFI filters should be UL1283 Listed for safety. 600 Volt 347/600 Volt 480 Volt Three Phase Delta Three Phase Wye Three Phase Delta 3 Wire plus Ground 4 Wire plus Ground 3 Wire plus Ground 88 WEATHERPROOF • ENERGY CONTROLS • PROFESSIONAL LIGHTING • POOL & SPA • SURGE PROTECTION • CONSUMER Standards and Guidelines ANSI/IEEE C62.41.1-2002 and ANSI/IEEE C62.41.2-2002 are the recognized American National Standards for establishing the surge withstand capability of equipment connected to utility power circuits in residential, commercial or industrial applications. The standard has established the following Location Categories which can be applied to virtually any type of facility. Category C Category B Category A • Outside and Service Entrance • Any underground lines • Overhead line to detached building • Feeders and short branch circuits • Distribution panel devices • Lighting systems in large buildings • Outlets and long branch circuits Service Entrance Meter Service Entrance Meter The following values and waveforms are recognized within Categories C, B and A. Location Category C is the Outside and Service Entrance and the harshest surge environment. C Combination Waves Ring Waves 1.2 x 50 microsecond / 8 x 20 microsecond 100KHz 0.5 microsecond Location Voltage (Peak) Category 1.2 x 50 µ sec. Current (Peak) 8 x 20 µ sec. Location Category Voltage (peak) Current (peak) A B C low C high 500 Amp 3,000 Amp 3,000 Amp 10,000 Amp A B 6,000 Volts 6,000 Volts 200 Amp 500 Amp 6,000 Volt 6,000 Volt 6,000 Volt 10,000 Volt The following guidelines can be followed for Intermatic products: Large Service Entrance (2000 to 4000 Amperes) Best PG5001-480-3DLL PG5001-480-3Y Better PG4501-480-3DLL PG4501-480-3Y Good PG4001-480-3DLL PG4001-480-3Y Small Service Entrance (Less than 1600 Amperes) Best PG4501-480-3DLL PG4501-480-3Y Better PG4001-480-3DLL PG4001-480-3Y Good PG100-480-3DLL PG100-480-3Y Large Distribution Panel (1000 to 1600 Amperes) Best PG4001-480-3DLL PG4001-480-3Y Better PG100-480-3DLL PG100-480-3Y Good PG80-480-3DLL PG80-480-3Y Small Distribution Panel (600 to 1000 Amperes) Best PG100-480-3DLL PG100-480-3Y Better PG80-480-3DLL PG80-480-3Y Good PG60-480-3DLL PG60-480-3Y Large Panelboard (225 to 400 Amperes) Best PG80-480-3DLL PG80-480-3Y Better PG60-480-3DLL PG60-480-3Y Good PG40-480-3D PG40-480-3Y Small Panelboard (60 to 200 Amperes) Best PG60-480-3DLL PG60-480-3Y Better PG40-480-3D PG40-480-3Y Good PG20-480-3D PG20-480-3Y A Nema Standard LS-1 is the National Electrical Manufacturers Association specification guideline for low voltage surge protection devices. Underwriters Laboratories – UL1449 has recently been revised (August 1998) and requires surge suppression devices to safely pass overvoltage tests, abnormal overvoltage tests, short circuit withstand tests as well as assigns suppress voltage ratings based on a 6 KV, 500 Amp combination wave or impulse. Product Selection Chart – Surge Suppression Recommendations Choose Model by Voltage and distance from incoming Service Location 480 VAC 277/480 VAC 120/208 VAC Wye B ANSI/IEEE C62.45 is the American National Standard for uniform testing of surge suppression devices. All Intermatic testing follows these guidelines. Refer to Page PG5001-208-3Y PG4501-208-3Y PG4001-208-3Y 90 91 92 PG4501-208-3Y PG4001-208-3Y PG100-208-3Y 91 92 93 PG4001-208-3Y PG100-208-3Y PG80-208-3Y 92 93 95 PG100-208-3Y PG80-208-3Y PG60-208-3Y 93 95 97 PG80-208-3Y PG60-208-3Y PG40-208-3Y 95 97 100 PG60-208-3Y PG40-208-3Y PG20-208-3Y 97 100 102 Note for the PG 60/80/100 models equivalent models are available in Nema 3R enclosures for outdoor applications (see PG2500, PG3000, PG3500 Series). UL1283 – The safety standard for EMI/RFI noise attenuation filters. While this device does not rate filters or performance – it does provide a level of testing to ensure the filter is safe for commercial application. There are four main factors to consider when specifying the appropriate device for your facility: 1. What is the amperage (size) of the Switchboard or Panelboard at the point of installation? 2. What is the geographic location of the facility?(i.e. the relative level of lightning exposure and utility grid switching activity) 3. What is the density of electronic equipment and how critical is the application? (i.e. a 7 x 24 computer data center would require a higher level of protection than a retail store) 4. What is the level of transient and noise producing loads within your facility? (i.e. a heavy industrial manufacturing environment or a densely populated computer data center would require a higher level of protection) NOTES: • Pick appropriate model to match the voltage of your Service Entrance, Distribution Panel or Panelboard. • See individual product pages for other available voltages. • A facility without any Service Entrance protection would warrant a higher level of protection at downstream locations. WEATHERPROOF • ENERGY CONTROLS • PROFESSIONAL LIGHTING • POOL & SPA • SURGE PROTECTION • CONSUMER 89 Surge Suppression System PG5000 Series Features • All mode Protection (L-N, L-G, N-G, L-L) • 40 kA Brute Force MOVs • 200 KAIC Surge Rated Fuses • Fault Current Tested to 200 KAIC • Easily Replaceable Master Surge Module • NEMA 3R Style Enclosure • Redundant Protection per mode 400kA PER PHASE • Safety Interlocked Disconnect • Thermally Protected MOVs for maximum safety • EMI/RFI Filtration – Up to 54 dB from 20 kHz to 100 MHz • UL1449, 2nd Edition and UL1283 Listed, cULus • Lugs accept #10 to #2 AWG • 10 year product warranty • Complementary Listed as Secondary Surge Arrester (OWHX,E135626) Integral Diagnostics • LED Indicator Lights • Form C Contacts • Intermatic Thermal Monitoring System • Digital Surge Counter • Audible Alarm Surge Current Capacity (8 x 20 usec) (per mode)2 Per Phase3 Intermatic MCOV1 Model L-G L-N L-G N-G L-L PG5001-240-2S 120/240 VAC Single Phase (split) 115% 200 kA 200 kA 200 kA 200 kA PG5001-208-3Y 120/208 VAC Three Phase Wye 115% 200 kA 200 kA 200 kA 200 kA PG5001-240-3HLD 120/240 VAC Three Phase High Leg Delta 115% 200 kA 200 kA 200 kA 200 kA The PG5000 Series is a hardwired suppression device (installed in parallel) and recommended for all ANSI/IEEE Category locations. Dimensions: 28.66"H x 15.11"W x 8.05"D Weight: 65 lbs. PG5001-480-3Y 277/480 VAC Three Phase Wye 115% 200 kA 200 kA 200 kA PG5001-480-3DLL 480 VAC Three Phase Delta 115% — — — PG5001-600-3Y 347/600 VAC Three Phase Wye 115% 200 kA 200 kA 200 kA PG5001-600-3D 600 VAC Three Phase Delta 115% — 200 kA — UL 1449 Clamping Voltage (SVR) 6 kV, 500 Amp (8 x 20 usec)4 L-N L-G N-G L-L 400 kA 400 V 400 V 330 V 700 V 400 kA 400 V 400 V 330 V 700 V 400 kA 400 V / (700 V) 400 V / (700 V) 330 V 900 V 200 kA 400 kA 800 V 700 V 700 V 1,500 V 200 kA 200 kA — — — 1,500 V 200 kA 400 kA 1,000 V 1,000 V 1,000 V 1,800 V 200 kA 400 kA — 1,500 V — 1,800 V NOTES: 1 MCOV is Maximum Continuous Operating Voltage expressed in percentage of nominal voltage. 2 All surge currents listed above are independently tested and verified per NEMA LS-1. 3 Per Phase is defined as L-N + L-G for three phase 4-wire wye systems; L-G + L-L for three phase 3-wire delta systems. 4 Let-Through Voltage measured with 6 inch lead lengths per UL Standard 1449, 2nd Edition. 90 WEATHERPROOF • ENERGY CONTROLS • PROFESSIONAL LIGHTING • POOL & SPA • SURGE PROTECTION • CONSUMER Surge Suppression System PG4500 Series Features • All mode Protection (L-N, L-G, N-G, L-L) • 40 kA Brute Force MOVs • 200 KAIC Surge Rated Fuses • Fault Current Tested to 200 KAIC • Easily Replaceable Master Surge Module • NEMA 3R Style Enclosure • Redundant Protection per mode • Safety Interlocked Disconnect • Thermally Protected MOVs for maximum safety • EMI/RFI Filtration – Up to 54 dB from 20 kHz to 100 MHz • UL1449, 2nd Edition and UL1283 Listed, cULus • Lugs accept #10 to #2 AWG • 10 year product warranty • Complementary Listed as Secondary Surge Arrester (OWHX,E135626) 300kA PER PHASE Integral Diagnostics • LED Indicator Lights • Form C Contacts • Intermatic Thermal Monitoring System • Digital Surge Counter • Audible Alarm Surge Current Capacity (8 x 20 usec) (per mode)2 Per Phase3 Intermatic MCOV1 Model L-G L-N L-G N-G L-L PG4501-240-2S 120/240 VAC Single Phase (split) 115% 150 kA 150 kA 150 kA 150 kA PG4501-208-3Y 120/208 VAC Three Phase Wye 115% 150 kA 150 kA 150 kA 150 kA PG4501-240-3HLD 120/240 VAC Three Phase High Leg Delta 115% 150 kA 150 kA 150 kA 150 kA PG4501-480-3Y 277/480 VAC Three Phase Wye 115% 150 kA 150 kA 150 kA PG4501-480-3DLL 480 VAC Three Phase Delta 115% — — — PG4501-600-3Y 347/600 VAC Three Phase Wye 115% 150 kA 150 kA 150 kA PG4501-600-3D 600 VAC Three Phase Delta 115% — 150 kA — UL 1449 Clamping Voltage (SVR) 6 kV, 500 Amp (8 x 20 usec)4 L-N L-G N-G L-L 300 kA 400 V 400 V 330 V 700 V 300 kA 400 V 400 V 330 V 700 V 300 kA 400 V / (700 V) 400 V / (700 V) 330 V 900 V 150 kA 300 kA 800 V 700 V 700 V 1,500 V 150 kA 150 kA — — — 1,500 V 150 kA 300 kA 1,000 V 1,000 V 1,000 V 1,800 V 150 kA 300 kA — 1,500 V — 1,800 V The PG4500 Series is a hardwired suppression device (installed in parallel) and recommended for all ANSI/IEEE Category locations. Dimensions: 28.66"H x 15.11"W x 8.05"D Weight: 65 lbs. NOTES: 1 MCOV is Maximum Continuous Operating Voltage expressed in percentage of nominal voltage. 2 All surge currents listed above are independently tested and verified per NEMA LS-1. 3 Per Phase is defined as L-N + L-G for three phase 4-wire wye systems; L-G + L-L for three phase 3-wire delta systems. 4 Let-Through Voltage measured with 6 inch lead lengths per UL Standard 1449, 2nd Edition. WEATHERPROOF • ENERGY CONTROLS • PROFESSIONAL LIGHTING • POOL & SPA • SURGE PROTECTION • CONSUMER 91 Surge Suppression System PG4000 Series Features • All mode Protection (L-N, L-G, N-G, L-L) • Safety Interlocked Disconnect • 40 kA Brute Force MOVs • Thermally Protected MOVs for maximum safety • 200 KAIC Surge Rated Fuses • EMI/RFI Filtration – Up to 54 dB from 20 kHz to 100 MHz • Fault Current Tested to 200 KAIC • UL1449, 2nd Edition and UL1283 Listed, cULus • Easily Replaceable Master Surge Module • Lugs accept #10 to #2 AWG • NEMA 3R Style Enclosure • 10 year product warranty • Redundant Protection per mode • Redundant Protection per mode • Complementary Listed as Secondary Surge Arrester (OWHX,E135626) 250kA PER PHASE Integral Diagnostics • LED Indicator Lights • Form C Contacts • Intermatic Thermal Monitoring System • Digital Surge Counter • Audible Alarm Surge Current Capacity (8 x 20 usec) (per mode)2 The PG4000 Series is a hardwired suppression device (installed in parallel) and recommended for all ANSI/IEEE Category locations. Dimensions: 28.66"H x 15.11"W x 8.05"D Weight: 65 lbs. Per Phase3 Intermatic MCOV1 Model L-G L-N L-G N-G L-L PG4001-240-2S 120/240 VAC Single Phase (split) 115% 125 kA 125 kA 125 kA 125 kA PG4001-208-3Y 120/208 VAC Three Phase Wye 115% 125 kA 125 kA 125 kA 125 kA PG4001-240-3HLD 120/240 VAC Three Phase High Leg Delta 115% 125 kA 125 kA 125 kA 125 kA PG4001-480-3Y 277/480 VAC Three Phase Wye 115% 125 kA 125 kA 125 kA PG4001-480-3DLL 480 VAC Three Phase Delta 115% — — — PG4001-600-3Y 347/600 VAC Three Phase Wye 115% 125 kA 125 kA 125 kA PG4001-600-3D 600 VAC Three Phase Delta 115% — 125 kA — UL 1449 Clamping Voltage (SVR) 6 kV, 500 Amp (8 x 20 usec)4 L-N L-G N-G L-L 250 kA 400 V 400 V 330 V 700 V 250 kA 400 V 400 V 330 V 700 V 250 kA 400 V / (700 V) 400 V / (700 V) 330 V 900 V 125 kA 250 kA 800 V 700 V 700 V 1,500 V 125 kA 125 kA — — — 1,500 V 125 kA 250 kA 1,000 V 1,000 V 1,000 V 1,800 V 125 kA 250 kA — 1,500 V — 1,800 V NOTES: 1 MCOV is Maximum Continuous Operating Voltage expressed in percentage of nominal voltage. 2 All surge currents listed above are independently tested and verified per NEMA LS-1. 3 Per Phase is defined as L-N + L-G for three phase 4-wire wye systems; L-G + L-L for three phase 3-wire delta systems. 4 Let-Through Voltage measured with 6 inch lead lengths per UL Standard 1449, 2nd Edition. 92 WEATHERPROOF • ENERGY CONTROLS • PROFESSIONAL LIGHTING • POOL & SPA • SURGE PROTECTION • CONSUMER Surge Suppression System PG100 Series Features • Panel Extension design for mounting above or below 20" wide panel • Available wiring space on each side for branch circuit or main input conductors • All mode Protection (L-N, L-G, N-G, L-L) • Redundant Protection per mode, replaceable master module • Integral 200 KAIC fusing and thermal protection • Fault Current Tested to 200 KAIC • Complementary Listed as Secondary Surge Arrester (OWHX,E135626) • UL1449, 2nd Edition and UL1283 Listed, cULus • NEMA 12 Style Enclosure • Lugs accept #10 to #2 AWG • Available with flush mount cover PG1-FMP • 10 year product warranty • EMI/RFI Filtration – Up to 54 dB from 20 kHz to 100 MHz Integral Diagnostics • LED Indicator Lights for each mode • Form C Contacts • Audible Alarm Surge Current Capacity (8 x 20 usec) (per mode)2 Per Phase3 Intermatic MCOV1 Model L-G L-N L-G N-G L-L PG100-240-2S 120/240 VAC Single Phase (split) 115% 100 kA 100 kA 100 kA 100 kA PG100-208-3Y 120/208 VAC Three Phase Wye 115% 100 kA 100 kA 100 kA 100 kA PG100-240-3HLD 120/240 VAC Three Phase High Leg Delta 115% 100 kA 100 kA 100 kA 100 kA PG100-480-3Y 277/480 VAC Three Phase Wye 115% 100 kA 100 kA 100 kA PG100-480-3DLL 480 VAC Three Phase Delta 115% — — — UL 1449 Clamping Voltage (SVR) 6 kV, 500 Amp (8 x 20 usec)4 L-N L-G N-G L-L 200 kA 330 V 330 V 330 V 600 V 200 kA 330 V 330 V 330 V 600 V 200 kA 330 V (600 V) 330 V (700 V) 330 V 900 V 100 kA 200 kA 800 V 800 V 700 V 1,500 V 100 kA 100 kA — — — 1,200 V 200kA PER PHASE The PG100 Series is a hard wired suppression device installed in parallel) and recommended for all ANSI/IEEE Category locations. Dimensions: 16.0”H x 20.0”W x 6.0”D Weight: 40 lbs NOTES: 1 MCOV is Maximum Continuous Operating Voltage expressed in percentage of nominal voltage. 2 All surge currents listed above are independently tested and verified per NEMA LS-1. 3 Per Phase is defined as L-N + L-G for three phase 4-wire wye systems; L-G + L-L for three phase 3-wire delta systems. 4 Let-Through Voltage measured with 6 inch lead lengths per UL Standard 1449, 2nd Edition. Flush Mount Plate PG1-FMP WEATHERPROOF • ENERGY CONTROLS • PROFESSIONAL LIGHTING • POOL & SPA • SURGE PROTECTION • CONSUMER 93 Surge Suppression System PG3500 Series Features • All mode Protection (L-N, L-G, N-G, L-L) • Redundant Protection per mode • 40 kA Brute Force MOVs • Thermally Protected MOVs for maximum safety • 200 KAIC Surge Rated Fuses • EMI/RFI Filtration – Up to 54 dB from 20 kHz to 100 MHz • Fault Current Tested to 200 KAIC • UL1449, 2nd Edition and UL1283 Listed, cULus • Easily Replaceable Master Surge Module • Lugs accept #10 to #2 AWG • NEMA 3R Style Enclosure • 10 year product warranty • Complementary Listed as Secondary Surge Arrester (OWHX,E135626) 200kA PER PHASE Integral Diagnostics • LED Indicator Lights • Intermatic Thermal Monitoring System • Audible Alarm • Form C Contacts Surge Current Capacity (8 x 20 usec) (per mode)2 Per Phase3 Intermatic MCOV1 Model L-G L-N L-G N-G L-L PG3500-240-2S 120/240 VAC Single Phase (split) 115% 100 kA 100 kA 100 kA 100 kA PG3500-208-3Y 120/208 VAC Three Phase Wye 115% 100 kA 100 kA 100 kA 100 kA PG3500-240-3HLD 120/240 VAC Three Phase High Leg Delta 115% 100 kA 100 kA 100 kA 100 kA The PG3500 Series is a hardwired suppression device (installed in parallel) and recommended for all ANSI/IEEE Category locations. Dimensions: 28.66"H x 15.11"W x 8.05"D Weight: 60 lbs. PG3500-480-3Y 277/480 VAC Three Phase Wye 115% 100 kA 100 kA 100 kA PG3500-480-3DLL 480 VAC Three Phase Delta 115% — — — PG3500-600-3Y 347/600 VAC Three Phase Wye 115% 100 kA 100 kA 100 kA PG3500-600-3D 600 VAC Three Phase Delta 115% — 100 kA — UL 1449 Clamping Voltage (SVR) 6 kV, 500 Amp (8 x 20 usec)4 L-N L-G N-G L-L 200 kA 400 V 400 V 330 V 700 V 200 kA 400 V 400 V 330 V 700 V 200 kA 400 V / (700 V) 400 V / (700 V) 330 V 900 V 100 kA 200 kA 800 V 700 V 700 V 1,500 V 100 kA 100 kA — — — 1,500 V 100 kA 200 kA 1,000 V 1,000 V 1,000 V 1,800 V 100 kA 200 kA — 1,500 V — 1,800 V NOTES: 1 MCOV is Maximum Continuous Operating Voltage expressed in percentage of nominal voltage. 2 All surge currents listed above are independently tested and verified per NEMA LS-1. 3 Per Phase is defined as L-N + L-G for three phase 4-wire wye systems; L-G + L-L for three phase 3-wire delta systems. 4 Let-Through Voltage measured with 6 inch lead lengths per UL Standard 1449, 2nd Edition. 94 WEATHERPROOF • ENERGY CONTROLS • PROFESSIONAL LIGHTING • POOL & SPA • SURGE PROTECTION • CONSUMER Surge Suppression System PG80 Series Features • Panel Extension design for mounting above or below 20" wide panel • Available wiring space on each side for branch circuit or main input conductors • All mode Protection (L-N, L-G, N-G, L-L) • Redundant Protection per mode, replaceable master module • Integral 200 KAIC fusing and thermal protection • EMI/RFI Filtration – Up to 54 dB from 20 kHz to 100 MHz • Complementary Listed as Secondary Surge Arrester (OWHX,E135626) • UL1449, 2nd Edition and UL1283 Listed, cULus • NEMA 12 Style Enclosure • Lugs accept #10 to #2 AWG • Available with flush mount cover PG1-FMP • 10 year product warranty • Fault Current Tested to 200 KAIC 160kA PER PHASE Integral Diagnostics • LED Indicator Lights for each mode • Form C Contacts • Audible Alarm Surge Current Capacity (8 x 20 usec) (per mode)2 Per Phase3 Intermatic MCOV1 Model L-G L-N L-G N-G L-L PG80-240-2S 120/240 VAC Single Phase (split) 115% 80 kA 80 kA 80 kA 80 kA PG80-208-3Y 120/208 VAC Three Phase Wye 115% 80 kA 80 kA 80 kA 80 kA PG80-240-3HLD 120/240 VAC Three Phase High Leg Delta 115% 80 kA 80 kA 80 kA 80 kA PG80-480-3Y 277/480 VAC Three Phase Wye 115% 80 kA 80 kA 80 kA PG80-480-3DLL 480 VAC Three Phase Delta 115% — 80 kA — UL 1449 Clamping Voltage (SVR) 6 kV, 500 Amp (8 x 20 usec)4 L-N L-G N-G L-L 160 kA 330 V 330 V 330 V 600 V 160 kA 330 V 330 V 330 V 600 V 160 kA 330 V (600 V) 330 V (700 V) 330 V 900 V 80 kA 160 kA 800 V 800 V 700 V 1500 V 80 kA 80 kA — — — 1,200 V The PG80 Series is a hardwired suppression device (installed in parallel) and recommended for all ANSI/IEEE Category locations. Dimensions: 16.0"H x 20.0"W x 6.0"D Weight: 40 lbs. NOTES: 1 MCOV is Maximum Continuous Operating Voltage expressed in percentage of nominal voltage. 2 All surge currents listed above are independently tested and verified per NEMA LS-1. 3 Per Phase is defined as L-N + L-G for three phase 4-wire wye systems; L-G + L-L for three phase 3-wire delta systems. 4 Let-Through Voltage measured with 6 inch lead lengths per UL Standard 1449, 2nd Edition. Flush Mount Plate PG1-FMP WEATHERPROOF • ENERGY CONTROLS • PROFESSIONAL LIGHTING • POOL & SPA • SURGE PROTECTION • CONSUMER 95 Surge Suppression System PG3000 Series Features • All mode Protection (L-N, L-G, N-G, L-L) • 40 kA Brute Force MOVs • Thermally Protected MOVs for maximum safety • EMI/RFI Filtration – Up to 54 dB from 20 kHz to 100 MHz • UL1449, 2nd Edition and UL1283 Listed, cULus • 10 year product warranty 160kA PER PHASE • Redundant Protection per mode • 200 KAIC Surge Rated Fuses • Fault Current Tested to 200 KAIC • Easily Replaceable Master Surge Module • NEMA 3R Style Enclosure • Complementary Listed as Secondary Surge Arrester (OWHX,E135626) Integral Diagnostics • LED Indicator Lights • Intermatic Thermal Monitoring System • Audible Alarm • Form C Contacts Surge Current Capacity (8 x 20 usec) (per mode)2 The PG3000 Series is a hardwired suppression device (installed in parallel) and recommended for all ANSI/IEEE Category locations. Dimensions: 28.66"H x 15.11"W x 8.05"D Weight: 60 lbs. Per Phase3 Intermatic MCOV1 Model L-G L-N L-G N-G L-L PG3000-240-2S 120/240 VAC Single Phase (split) 115% 80 kA 80 kA 80 kA 80 kA PG3000-208-3Y 120/208 VAC Three Phase Wye 115% 80 kA 80 kA 80 kA 80 kA PG3000-240-3HLD 120/240 VAC Three Phase High Leg Delta 115% 80 kA 80 kA 80 kA 80 kA PG3000-480-3Y 277/480 VAC Three Phase Wye 115% 80 kA 80 kA 80 kA PG3000-480-3DLL 480 VAC Three Phase Delta 115% — — — PG3000-600-3Y 347/600 VAC Three Phase Wye 115% 80 kA 80 kA 80 kA PG3000-600-3D 600 VAC Three Phase Delta 115% — 80 kA — UL 1449 Clamping Voltage (SVR) 6 kV, 500 Amp (8 x 20 usec)4 L-N L-G N-G L-L 160 kA 400 V 400 V 330 V 700 V 160 kA 400 V 400 V 330 V 700 V 160 kA 400 V / (700 V) 400 V / (700 V) 330 V 900 V 80 kA 160 kA 800 V 700 V 700 V 1,500 V 80 kA 80 kA — — — 1,500 V 80 kA 160 kA 1,000 V 1,000 V 1,000 V 1,800 V 80 kA 160 kA — 1,500 V — 1,800 V NOTES: 1 MCOV is Maximum Continuous Operating Voltage expressed in percentage of nominal voltage. 2 All surge currents listed above are independently tested and verified per NEMA LS-1. 3 Per Phase is defined as L-N + L-G for three phase 4-wire wye systems; L-G + L-L for three phase 3-wire delta systems. 4 Let-Through Voltage measured with 6 inch lead lengths per UL Standard 1449, 2nd Edition. 96 WEATHERPROOF • ENERGY CONTROLS • PROFESSIONAL LIGHTING • POOL & SPA • SURGE PROTECTION • CONSUMER Surge Suppression System PG60 Series Features • Panel Extension design for mounting above or below 20" wide panel • Available wiring space on each side for branch circuit or main input conductors • All mode Protection (L-N, L-G, N-G, L-L) • Redundant Protection per mode, replaceable master module • Integral 200 KAIC fusing and thermal protection • EMI/RFI Filtration – Up to 54 dB from 20 kHz to 100 MHz • Complementary Listed as Secondary Surge Arrester (OWHX,E135626) • UL1449, 2nd Edition and UL1283 Listed, cULus • NEMA 12 Style Enclosure • Lugs accept #10 to #2 AWG • Available with flush mount cover PG1-FMP • 10 year product warranty • Fault Current Tested to 200 KAIC Integral Diagnostics 120kA PER PHASE • LED Indicator Lights for each mode • Form C Contacts • Audible Alarm Surge Current Capacity (8 x 20 usec) (per mode)2 Per Phase3 Intermatic MCOV1 Model L-G L-N L-G N-G L-L PG60-240-2S 120/240 VAC Single Phase (split) 115% 60 kA 60 kA 60 kA 60 kA PG60-208-3Y 120/208 VAC Three Phase Wye 115% 60 kA 60 kA 60 kA 60 kA PG60-240-3HLD 120/240 VAC Three Phase High Leg Delta 115% 60 kA 60 kA 60 kA 60 kA PG60-480-3Y 277/480 VAC Three Phase Wye 115% 60 kA 60 kA 60 kA PG60-480-3DLL 480 VAC Three Phase Delta 115% — — — UL 1449 Clamping Voltage (SVR) 6 kV, 500 Amp (8 x 20 usec)4 L-N L-G N-G L-L 120 kA 330 V 330 V 330 V 600 V 120 kA 330 V 330 V 330 V 600 V 120 kA 330 V (600 V) 330 V (700 V) 330 V 900 V 60 kA 120 kA 800 V 800 V 700 V 1,500 V 60 kA 60 kA — — — 1,200 V The PG60 Series is a hardwired suppression device (installed in parallel) and recommended for all ANSI/IEEE Category locations. Dimensions: 16.0"H x 20.0"W x 6.0"D Weight: 40 lbs. NOTES: 1 MCOV is Maximum Continuous Operating Voltage expressed in percentage of nominal voltage. 2 All surge currents listed above are independently tested and verified per NEMA LS-1. 3 Per Phase is defined as L-N + L-G for three phase 4-wire wye systems; L-G + L-L for three phase 3-wire delta systems. 4 Let-Through Voltage measured with 6 inch lead lengths per UL Standard 1449, 2nd Edition. Flush Mount Plate PG1-FMP WEATHERPROOF • ENERGY CONTROLS • PROFESSIONAL LIGHTING • POOL & SPA • SURGE PROTECTION • CONSUMER 97 Surge Suppression System PG2500 Series Features • All mode Protection (L-N, L-G, N-G, L-L) • Redundant Protection per mode • 200 KAIC Surge Rated Fuses • Thermally Protected MOVs for maximum safety • Fault Current Tested to 200 KAIC • Complementary Listed as Secondary Surge Arrester (OWHX,E135626) • EMI/RFI Filtration – Up to 54 dB from 20 kHz to 100 MHz • UL1449, 2nd Edition and UL1283 Listed, cULus • NEMA 3R Style Enclosure • Pre-wired with 40" of #10 AWG wire leads • 10 year product warranty Integral Diagnostics • LED Indicator Lights for each mode • Form C Contacts • Audible Alarm Surge Current Capacity (8 x 20 usec) (per mode)2 120kA PER PHASE The PG2500 Series is a hardwired suppression device (installed in parallel) and recommended for all ANSI/IEEE Category locations. Dimensions: 16.47"H x 10.59"W x 4.9"D Weight: 28 lbs. Per Phase3 Intermatic MCOV1 Model L-G L-N L-G N-G L-L IG2401SECA 120/240 VAC Single-Phase (Split) 115% 60 kA 60 kA 60 kA 60 kA IG2083YECA 120/208 VAC Three Phase Wye 115% 60 kA 60 kA 60 kA 60 kA IG2403DECA 120/240 VAC Three Phase High Leg Delta 115% 60 kA 60 kA 60 kA 60 kA IG4803YECA 277/480 VAC Three Phase Wye 115% 60 kA 60 kA 60 kA IG4803DECA 480 VAC Three Phase Delta 115% — 120 kA — UL 1449 Clamping Voltage (SVR) 6 kV, 500 Amp (8 x 20 usec)4 L-N L-G N-G L-L 120 kA 400 V 400 V 330 V 600 V 120 kA 400 V 400 V 330 V 600 V 120 kA 400 V / (600 V) 400 V / (700 V) 330 V 700 V 60 kA 120 kA 800 V 800 V 400 V 1,500 V 60 kA 180 kA — 1,500 V — 1,200 V NOTES: 1 MCOV is Maximum Continuous Operating Voltage expressed in percentage of nominal voltage. 2 All surge currents listed above are independently tested and verified per NEMA LS-1. 3 Per Phase is defined as L-N + L-G for three phase 4-wire wye systems; L-G + L-L for three phase 3-wire delta systems. 4 Let-Through Voltage measured with 6 inch lead lengths per UL Standard 1449, 2nd Edition. Flush Mount Plate IG1FMP-PG 98 WEATHERPROOF • ENERGY CONTROLS • PROFESSIONAL LIGHTING • POOL & SPA • SURGE PROTECTION • CONSUMER Surge Suppression System PG2000 Series Features • All mode Protection (L-N, L-G, N-G, L-L) • Redundant Protection per mode • 200 KAIC Surge Rated Fuses • Thermally Protected MOVs for maximum safety • Fault Current Tested to 200 KAIC • Complementary Listed as Secondary Surge Arrester (OWHX,E135626) • EMI/RFI Filtration – Up to 54 dB from 20 kHz to 100 MHz • UL1449, 2nd Edition and UL1283 Listed, cULus • NEMA 3R Style Enclosure • Pre-wired with 40" of #10 AWG wire leads • 10 year product warranty Integral Diagnostics • LED Indicator Lights • Form C Contacts • Intermatic Thermal Monitoring System Surge Current Capacity (8 x 20 usec) (per mode)2 Intermatic MCOV1 Model L-G IG2401ECS 120/240 VAC 115% IG2083ECY 120/208 VAC 115% IG2403ECD 120/240 VAC 115% Per Phase3 UL 1449 Clamping Voltage (SVR) 6 kV, 500 Amp (8 x 20 usec)4 60kA PER PHASE L-N L-G N-G Single-Phase (Split) 30 kA 30 kA 30 kA Three Phase Wye 30 kA 30 kA 30 kA Three Phase High Leg Delta 30 kA 30 kA 30 kA IG4803ECY 277/480 VAC Three Phase Wye 115% 30 kA 30 kA IG4803ECD 480 VAC Three Phase Delta 115% — 60 kA L-L L-N L-G N-G L-L 30 kA 60 kA 500 V 400 V 400 V 700 V 30 kA 60 kA 400 V 500 V 400 V 700 V 30 kA 60 kA 400 V / (700 V) 400 V / (700 V) 330 V 700 V 30 kA 30 kA 60 kA 800 V 800 V 400 V 1,500 V — 30 kA 90 kA — 1,500 V — 1,500 V The PG2000 Series is a hardwired suppression device (installed in parallel) and recommended for all ANSI/IEEE Category locations. Dimensions: 16.47"H x 10.59"W x 4.9"D Weight: 28 lbs. NOTES: 1 MCOV is Maximum Continuous Operating Voltage expressed in percentage of nominal voltage. 2 All surge currents listed above are independently tested and verified per NEMA LS-1. 3 Per Phase is defined as L-N + L-G for three phase 4-wire wye systems; L-G + L-L for three phase 3-wire delta systems. 4 Let-Through Voltage measured with 6 inch lead lengths per UL Standard 1449, 2nd Edition. Flush Mount Plate IG1FMP-PG WEATHERPROOF • ENERGY CONTROLS • PROFESSIONAL LIGHTING • POOL & SPA • SURGE PROTECTION • CONSUMER 99 Surge Suppression System PG40 Series Features • All mode Protection (L-N, L-G, N-G, L-L) • Redundant Protection per mode • Integral 200 KAIC fusing and thermal protection • Thermally protected MOVs for maximum safety • Fault current tested to 200 KAIC • EMI/RFI Filtration – Up to 54 dB from 20 kHz to 100 MHz • UL1449, 2nd Edition and UL1283 Listed, cULus • NEMA 4 style enclosure • Pre-wired with 30" of #10 AWG wire leads • Available with flush mount cover PG2-FMP • 10 year product warranty • Complementary Listed as Secondary Surge Arrester (OWHX,E135626) Integral Diagnostics • LED indicator lights for each mode • Form C Contacts • Audible alarm Surge Current Capacity (8 x 20 usec) (per mode)2 80kA PER PHASE The PG40 Series is a hardwired suppression device (installed in parallel) and recommended for all ANSI/IEEE Category locations. Dimensions: 11.0"H x 5.875"W x 3.75"D Weight: 22 lbs. Per Phase3 Intermatic MCOV1 Model L-G L-N L-G N-G L-L PG40-240-2S 120/240 VAC Single Phase (split) 115% 40 kA 40 kA 40 kA 40 kA PG40-208-3Y 120/208 VAC Three Phase Wye 115% 40 kA 40 kA 40 kA 40 kA PG40-240-3HLD 120/240 VAC Three Phase High Leg Delta 115% 40 kA 40 kA 40 kA 40 kA PG40-480-3Y 277/480 VAC Three Phase Wye 115% 40 kA 40 kA 40 kA PG40-480-3D 480 VAC Three Phase Delta 115% — 40 kA — UL 1449 Clamping Voltage (SVR) 6 kV, 500 Amp (8 x 20 usec)4 L-N L-G N-G L-L 80 kA 330 V 330 V 400 V 700 V 80 kA 330 V 330 V 400 V 700 V 80 kA 330 V (600 V) 330 V (600 V) 400 V 900 V 40 kA 80 kA 800 V 800 V 800 V 1,500 V 40 kA 80 kA — 1,200 V — 1,200 NOTES: 1 MCOV is Maximum Continuous Operating Voltage expressed in percentage of nominal voltage. 2 All surge currents listed above are independently tested and verified per NEMA LS-1. 3 Per Phase is defined as L-N + L-G for three phase 4-wire wye systems; L-G + L-L for three phase 3-wire delta systems. 4 Let-Through Voltage measured with 6 inch lead lengths per UL Standard 1449, 2nd Edition. Flush Mount Plate PG2-FMP 100 WEATHERPROOF • ENERGY CONTROLS • PROFESSIONAL LIGHTING • POOL & SPA • SURGE PROTECTION • CONSUMER Surge Suppression System EH Series Features • All mode Protection (L-N, L-G, N-G, L-L) • Redundant Protection per mode • 200 KAIC Surge Rated Fuses • Thermally Protected MOVs for maximum safety • Fault Current Tested to 200 KAIC • Complementary Listed as Secondary Surge Arrester (OWHX,E135626) • EMI/RFI Filtration – 20 to 30 dB from 20 kHz to 100 MHz • UL1449, 2nd Edition Listed, cULus • NEMA 12 Style Enclosure • Pre-wired with 30" of #10 AWG wire leads • 10 year product warranty Integral Diagnostics • LED Indicator Lights • Intermatic Thermal Monitoring System Surge Current Capacity (8 x 20 usec) (per mode)2 Per Phase3 Intermatic MCOV1 Model L-G L-N L-G N-G L-L IG1201EH 120 VAC Single Phase 115% 26 kA 26 kA 26 kA — IG2401EH 120/240 VAC Single Phase (split) 115% 26 kA 26 kA 26 kA 26 kA IG2083YEH 120/208 VAC Three Phase Wye 115% 26 kA 26 kA 26 kA 26 kA IG2403DEH 120/240 VAC Three Phase High Leg Delta 115% 26 kA 26 kA 26 kA 26 kA IG4803YEH 277/480 VAC Three Phase Wye 115% 26 kA 26 kA 26 kA IG4803DEH 480 VAC Three Phase Delta 115% — 52 kA — UL 1449 Clamping Voltage (SVR) 6 kV, 500 Amp (8 x 20 usec)4 52kA PER PHASE L-N L-G N-G L-L 52 kA 500 V 500 V 500 V — 52 kA 400 V 400 V 400 V 700 V 52 kA 400 V 400 V 400 V 700 V 52 kA 400 V / (700 V) 400 V / (700 V) 400 V 700 V 26 kA 52 kA 800 V 800 V 400 V 1,500 V 26 kA 78 kA — 1,200 V — 1,500 V NOTES: 1 MCOV is Maximum Continuous Operating Voltage expressed in percentage of nominal voltage. 2 All surge currents listed above are independently tested and verified per NEMA LS-1. 3 Per Phase is defined as L-N + L-G for three phase 4-wire wye systems; L-G + L-L for three phase 3-wire delta systems. 4 Let-Through Voltage measured with 6 inch lead lengths per UL Standard 1449, 2nd Edition. The EH Series is a hardwired suppression device (installed in parallel) and recommended for all ANSI/IEEE Category locations. Dimensions: 7.5"H x 4.25"W x 4.0"D Weight: 5.5 lbs. Flush Mount Plate IG1FMP-H WEATHERPROOF • ENERGY CONTROLS • PROFESSIONAL LIGHTING • POOL & SPA • SURGE PROTECTION • CONSUMER 101 Surge Suppression System PG20 Series Features • All mode Protection (L-N, L-G, N-G, L-L) • Redundant Protection per mode • Integral 200 KAIC fusing and thermal protection • Thermally protected MOVs for maximum safety • Fault current tested to 200 KAIC • EMI/RFI Filtration – Up to 54 dB from 20 kHz to 100 MHz • UL1449, 2nd Edition and UL1283 Listed, cULus • NEMA 4 style enclosure • Pre-wired with 30" of #10 AWG wire leads • Available with flush mount cover PG2-FMP • 10 year product warranty • Complementary Listed as Secondary Surge Arrester (OWHX,E135626) Integral Diagnostics • LED indicator lights for each mode • Form C Contacts • Audible alarm Surge Current Capacity (8 x 20 usec) (per mode)2 40kA PER PHASE The PG20 Series is a hardwired suppression device (installed in parallel) and recommended for all ANSI/IEEE Category locations. Dimensions: 11.0"H x 5.875"W x 3.75"D Weight: 22 lbs. Per Phase3 Intermatic MCOV1 Model L-G L-N L-G N-G L-L PG20-240-2S 120/240 VAC Single Phase (split) 115% 20 kA 20 kA 20 kA 20 kA PG20-208-3Y 120/208 VAC Three Phase Wye 115% 20 kA 20 kA 20 kA 20 kA PG20-240-3HLD 120/240 VAC Three Phase High Leg Delta 115% 20 kA 20 kA 20 kA 20 kA PG20-480-3Y 277/480 VAC Three Phase Wye 115% 20 kA 20 kA 20 kA PG20-480-3D 480 VAC Three Phase Delta 115% — 20 kA — UL 1449 Clamping Voltage (SVR) 6 kV, 500 Amp (8 x 20 usec)4 L-N L-G N-G L-L 40 kA 330 V 330 V 400 V 700 V 40 kA 330 V 330 V 400 V 700 V 40 kA 330 V (600 V) 330 V (600 V) 400 V 900 V 20 kA 40 kA 800 V 800 V 800 V 1,500 V 20 kA 40 kA — 1,200 V — 1,200 V NOTES: 1 MCOV is Maximum Continuous Operating Voltage expressed in percentage of nominal voltage. 2 All surge currents listed above are independently tested and verified per NEMA LS-1. 3 Per Phase is defined as L-N + L-G for three phase 4-wire wye systems; L-G + L-L for three phase 3-wire delta systems. 4 Let-Through Voltage measured with 6 inch lead lengths per UL Standard 1449, 2nd Edition. Flush Mount Plate PG2-FMP 102 WEATHERPROOF • ENERGY CONTROLS • PROFESSIONAL LIGHTING • POOL & SPA • SURGE PROTECTION • CONSUMER Surge Suppression System LH Series Features • All mode Protection (L-N, L-G, N-G, L-L) • 200 KAIC Surge Rated Fuses • Thermally Protected MOVs for maximum safety • Fault Current Tested to 200 KAIC • EMI/RFI Filtration – 20 to 30 dB from 20 kHz to 100 MHz • UL1449, 2nd Edition, cULus • NEMA 12 Style Enclosure • Pre-wired with 30" of #10 AWG wire leads • 10 year product warranty • Complementary Listed as Secondary Surge Arrester (OWHX,E135626) Integral Diagnostics 26kA PER PHASE • LED Indicator Lights • Intermatic Thermal Monitoring System Surge Current Capacity (8 x 20 usec) (per mode)2 Per Phase3 Intermatic MCOV1 Model L-G L-N L-G N-G L-L IG1201LH 120 VAC Single Phase 115% 13 kA 13 kA 13 kA — IG2401LH 120/240 VAC Single Phase (split) 115% 13 kA 13 kA 13 kA 13 kA IG2083LYH 120/208 VAC Three Phase Wye 115% 13 kA 13 kA 13 kA 13 kA IG2403LDH 120/240 VAC Three Phase High Leg Delta 115% 13 kA 13 kA 13 kA 13 kA IG4803LYH 277/480 VAC Three Phase Wye 115% 13 kA 13 kA IG4803LDH 480 VAC Three Phase Delta 115% — 26 kA UL 1449 Clamping Voltage (SVR) 6 kV, 500 Amp (8 x 20 usec)4 L-N L-G N-G L-L 26 kA 500 V 500 V 400 V — 26 kA 400 V 500 V 400 V 700 V 26 kA 500 V 500 V 400 V 700 V 26 kA 500 V / (700 V) 500 V / (700 V) 500 V 700 V 13 kA 13 kA 26 kA 800 V 800 V 500 V 1,500 V — 13 kA 39 kA — 1,500 V — 1,500 V The LH Series is a hardwired suppression device (installed in parallel) and recommended for ANSI/IEEE Category locations for A and B. Dimensions: 7.5"H x 4.25"W x 4.0"D Weight: 5.5 lbs. NOTES: 1 MCOV is Maximum Continuous Operating Voltage expressed in percentage of nominal voltage. 2 All surge currents listed above are independently tested and verified per NEMA LS-1. 3 Per Phase is defined as L-N + L-G for three phase 4-wire wye systems; L-G + L-L for three phase 3-wire delta systems. 4 Let-Through Voltage measured with 6 inch lead lengths per UL Standard 1449, 2nd Edition. Flush Mount Plate IG1FMP-H WEATHERPROOF • ENERGY CONTROLS • PROFESSIONAL LIGHTING • POOL & SPA • SURGE PROTECTION • CONSUMER 103 Surge Suppression System PG1500 Series Features • L-N, N-G protection modes (4 mode) • Redundant protection per mode • Integral 200 KAIC fusing and thermal protection • Thermally protected MOVs for maximum safety • Fault current tested to 200 KAIC • EMI/RFI filtration – Up to 54 dB from 20 kHz to 100 MHz • UL1449, 2nd Edition and UL1283 Listed, cULus • NEMA 4 style enclosure • Pre-wired with 30" of #10 AWG wire leads • Available with flush mount cover PG2-FMP • 10 year product warranty • Complementary Listed as Secondary Surge Arrester (OWHX,E135626) Integral Diagnostics • LED indicator lights for each mode • Form C Contacts • Audible alarm Surge Current Capacity (8 x 20 usec) (per mode)2 80kA PER PHASE The PG1500 Series is a hardwired suppression device (installed in parallel) and recommended for all ANSI/IEEE Category locations. Dimensions: 11.0"H x 5.875"W x 3.75"D Weight: 22 lbs. Intermatic MCOV1 Model L-N L-N L-G N-G PG1500-240-2S 120/240 VAC Single Phase (split) 115% 80 kA — 40 kA PG1500-208-3Y 120/208 VAC Three Phase Wye 115% 80 kA — 40 kA PG1500-480-3Y 277/480 VAC Three Phase Wye 115% 80 kA — 40 kA PG1500-480-3D 480 VAC Three Phase Delta 115% — 80 kA — Per Phase3 L-L UL 1449 Clamping Voltage (SVR) 6 kV, 500 Amp (8 x 20 usec)4 L-N L-G N-G L-L 80 kA 80 kA 330 V 700 V 400 V 600 V 80 kA 80 kA 330 V 700 V 400 V 600 V 80 kA 80 kA 800 V 1,500 V 800 V 1,500 V 80 kA 160 kA — 1,200 V — 1,200 V NOTES: 1 MCOV is Maximum Continuous Operating Voltage expressed in percentage of nominal voltage. 2 All surge currents listed above are independently tested and verified per NEMA LS-1. 3 Per Phase is defined as L-N + L-G for three phase 4-wire wye systems; L-G + L-L for three phase 3-wire delta systems. 4 Let-Through Voltage measured with 6 inch lead lengths per UL Standard 1449, 2nd Edition. Flush Mount Plate PG2-FMP 104 WEATHERPROOF • ENERGY CONTROLS • PROFESSIONAL LIGHTING • POOL & SPA • SURGE PROTECTION • CONSUMER Surge Suppression System PG1000 Series Features • L-N, N-G protection modes (4 mode) • Redundant protection per mode • Integral 200 KAIC fusing and thermal protection • Thermally protected MOVs for maximum safety • Fault current tested to 200 KAIC • EMI/RFI filtration – Up to 54 dB from 20 kHz to 100 MHz • UL1449, 2nd Edition and UL1283 Listed, cULus • NEMA 4 style enclosure • Pre-wired with 30" of #10 AWG wire leads • Available with flush mount cover PG2-FMP • 10 year product warranty • Complementary Listed as Secondary Surge Arrester (OWHX,E135626) Integral Diagnostics • LED indicator lights for each mode • Form C Contacts • Audible alarm Surge Current Capacity (8 x 20 usec) (per mode)2 Intermatic MCOV1 Model L-N L-N L-G N-G PG1000-240-2S 120/240 VAC Single Phase (split) 115% 40 kA — 40 kA PG1000-208-3Y 120/208 VAC Three Phase Wye 115% 40 kA — 40 kA PG1000-480-3Y 277/480 VAC Three Phase Wye 115% 40 kA — 40 kA PG1000-480-3D 480 VAC Three Phase Delta 115% — 40 kA — Per Phase3 L-L UL 1449 Clamping Voltage (SVR) 6 kV, 500 Amp (8 x 20 usec)4 L-N L-G N-G L-L 40 kA 40 kA 330 V 700 V 400 V 600 V 40 kA 40 kA 330 V 700 V 400 V 600 V 40 kA 40 kA 800 V 1,500 V 800 V 1,500 V 40 kA 80 kA — 1,200 V — 1,200 V NOTES: 1 MCOV is Maximum Continuous Operating Voltage expressed in percentage of nominal voltage. 2 All surge currents listed above are independently tested and verified per NEMA LS-1. 3 Per Phase is defined as L-N + L-G for three phase 4-wire wye systems; L-G + L-L for three phase 3-wire delta systems. 4 Let-Through Voltage measured with 6 inch lead lengths per UL Standard 1449, 2nd Edition. 40kA PER PHASE The PG1000 Series is a hardwired suppression device (installed in parallel) and recommended for all ANSI/IEEE Category locations. Dimensions: 11.0"H x 5.875"W x 3.75"D Weight: 22 lbs. Flush Mount Plate PG2-FMP WEATHERPROOF • ENERGY CONTROLS • PROFESSIONAL LIGHTING • POOL & SPA • SURGE PROTECTION • CONSUMER 105 Modular Protection System There are four main factors to consider when specifying the appropriate device for your facility: 1. What is the amperage (size) of the Switchboard or Panelboard at the point of installation? 2. What is the geographic location of the facility? (i.e. the relative level of lightning exposure and utility grid switching activity) 3. What is the density of electronic equipment and how critical is the application? (i.e. a 7 x 24 computer data center would require a higher level of protection than a retail store) Product Selection Chart – Modular Models The following guidelines can be followed for Intermatic products: Choose Model by Voltage Location 480 VAC Delta 277/480 VAC Wye Large Service Entrance 2000 to 4000 Amp Best SG320K-480-3D SG320K-480-3Y Better SG240K-480-3D SG240K-480-3Y Good UG40A4803D UG404803Y Small Service Entrance Less than 1600 Amp Best SG240K-480-3D SG240K-480-3Y Better SG160K-480-3D SG160K-480-3Y Good UG30A4803D UG30A4803Y Distribution Panel 1000 to 1600 Amp Best SG160K-480-3D SG160K-480-3Y Better UG30A4803D UG30A4803Y Good UG28A4803D UG28A4803Y Panelboard 60 to 400 Amp Best UG30A4803D UG30A4803Y Better UG28A4803D UG28A4803Y 120/208 VAC Wye Refer to Page SG320K-208-3Y SG240K-208-3Y UG40A2083Y 107 108 110 SG240K-208-3Y SG160K-208-3Y UG30A2083Y 108 109 111 SG160K-208-3Y UG30A2083Y UG28A2083Y 109 111 112 UG30A2083Y UG28A2083Y 111 112 4. What is the level of transient and noise producing loads within your facility? (i.e. a heavy industrial manufacturing environment or a densely populated computer data center would require a higher level of protection) NOTES: • Pick appropriate model to match the voltage of your Service Entrance, Distribution Panel or Panelboard. • See individual product pages for other available voltages. • A facility without any Service Entrance protection would warrant a higher level of protection at downstream locations. 106 WEATHERPROOF • ENERGY CONTROLS • PROFESSIONAL LIGHTING • POOL & SPA • SURGE PROTECTION • CONSUMER Modular Protection System SG320 Series Features • All mode Protection (L-N, L-G, N-G, L-L) • Fault Current Tested to 200 KAIC • EMI/RFI Filtration – Up to 50 dB from 20 kHz to 100 MHz • Replaceable Modules for low MTTR • NEMA 12 Enclosure • 40 kA Brute Force MOVs • Redundant Protection per mode • Thermally Protected MOVs for maximum safety • UL1449, 2nd Edition and UL1283 Listed, UL and cUL • 5 year product warranty Installation: • Recommended installation is with 30-100 Amp breaker Integral Diagnostics 320kA • LED Indicator Lights • Form C Contacts PER PHASE • Audible Alarm • Digital Surge Counter Surge Current Capacity (8 x 20 usec) (per mode) Per Phase2 Intermatic MCOV1 Model L-G L-N L-G N-G L-L SG320K-208-3Y 120/208 VAC Three Phase Wye 115% 160 kA 160 kA 120 kA 160 kA SG320K-240-3HLD 120/240 VAC Three Phase High Leg Delta 115% 160 kA 160 kA 120 kA 160 kA SG320K-480-3Y 277/480 VAC Three Phase Wye 115% 160 kA 160 kA 120 kA SG320K-480-3D 480 VAC Three Phase Delta 115% — 160 kA — UL 1449 Clamping Voltage (SVR) 6 kV, 500 Amp (8 x 20 usec)3 L-N L-G N-G L-L 320 kA 400 V 400 V 700 V 800 V 320 kA 400 V / (800 V) 400 V / (800 V) 700 V 800 V 160 kA 320 kA 800 V 800 V 1,500 V 1,500 V 160 kA 320 kA — 1,500 V — 2,500 V NOTES: 1 MCOV is Maximum Continuous Operating Voltage expressed in percent of nominal voltage. 2 Per Phase is defined as L-N + L-G for three phase 4-wire wye systems; L-G + L-L for three phase 3-wire delta systems. 3 Let-Through Voltage measured with 6 inch lead lengths per UL Standard 1449, 2nd Edition. The SG320 Series is a modular hardwired suppression device and recommended for all ANSI/IEEE Category locations. Contains one bolt-on module per phase for easy maintenance. Dimensions: 16"H x 14"W x 6"D Weight: 29 lbs. REPLACEMENT MODULE INFORMATION System Number: Quantity & Part Number SG320K-208-3Y (3) SG160-120V-M SG320K-240-3HLD (2) SG160-120V-M (1) SG160-240V-M SG320K-480-34 (3) SG160-277V-M (3) SG160-480V-M SG320K-480-3D WEATHERPROOF • ENERGY CONTROLS • PROFESSIONAL LIGHTING • POOL & SPA • SURGE PROTECTION • CONSUMER 107 Modular Protection System SG240 Series Features • All mode Protection (L-N, L-G, N-G, L-L) • Fault Current Tested to 200 KAIC • EMI/RFI Filtration – Up to 50 dB from 20 kHz to 100 MHz • Replaceable Modules for low MTTR • NEMA 12 Enclosure • 40 kA Brute Force MOVs • Redundant Protection per mode • Thermally Protected MOVs for maximum safety • UL1449, 2nd Edition and UL1283 Listed, UL and cUL • 5 year product warranty Installation: • Recommended installation is with 30-100 Amp breaker Integral Diagnostics 240kA • LED Indicator Lights • Form C Contacts PER PHASE • Audible Alarm • Digital Surge Counter Surge Current Capacity (8 x 20 usec) (per mode) Per Phase2 Intermatic MCOV1 Model L-G L-N L-G N-G L-L SG240K-208-3Y 120/208 VAC Three Phase Wye 115% 120 kA 120 kA 120 kA 120 kA SG240K-240-3HLD 120/240 VAC Three Phase High Leg Delta 115% 120 kA 120 kA 120 kA 120 kA SG240K-480-3Y 277/480 VAC Three Phase Wye 115% 120 kA 120 kA 120 kA SG240K-480-3D 480 VAC Three Phase Delta 115% — 120 kA — The SG240 Series is a modular hardwired suppression device and recommended for all ANSI/IEEE Category locations. Contains one bolt-on module per phase for easy maintenance. Dimensions: 16"H x 14"W x 6"D Weight: 28 lbs. UL 1449 Clamping Voltage (SVR) 6 kV, 500 Amp (8 x 20 usec)3 L-N L-G N-G L-L 240 kA 400 V 400 V 700 V 800 V 240 kA 400 V / (800 V) 400 V / (800 V) 700 V 800 V 120 kA 240 kA 800 V 800 V 1,500 V 1,500 V 120 kA 240 kA — 1,500 V — 2,500 V NOTES: 1 MCOV is Maximum Continuous Operating Voltage expressed in percent of nominal voltage. 2 Per Phase is defined as L-N + L-G for three phase 4-wire wye systems; L-G + L-L for three phase 3-wire delta systems. 3 Let-Through Voltage measured with 6 inch lead lengths per UL Standard 1449, 2nd Edition. REPLACEMENT MODULE INFORMATION Quantity & Part Number System Number: SG240K-208-3Y (3) SG120-120V-M SG240K-240-3HLD (2) SG120-120V-M (1) SG120-240V-M SG240K-480-34 (3) SG120-277V-M SG240K-480-3D (3) SG120-480V-M 108 WEATHERPROOF • ENERGY CONTROLS • PROFESSIONAL LIGHTING • POOL & SPA • SURGE PROTECTION • CONSUMER Modular Protection System SG160 Series Features • All mode Protection (L-N, L-G, N-G, L-L) • Fault Current Tested to 200 KAIC • EMI/RFI Filtration – Up to 50 dB from 20 kHz to 100 MHz • Replaceable Modules for low MTTR • NEMA 12 Enclosure • 40 kA Brute Force MOVs • Redundant Protection per mode • Thermally Protected MOVs for maximum safety • UL1449, 2nd Edition and UL1283 Listed, UL and cUL • 5 year product warranty Installation: • Recommended installation is with 30-100 Amp breaker Integral Diagnostics 160kA • LED Indicator Lights • Form C Contacts PER PHASE • Audible Alarm • Digital Surge Counter Surge Current Capacity (8 x 20 usec) (per mode) Per Phase2 Intermatic MCOV1 Model L-G L-N L-G N-G L-L SG160K-208-3Y 120/208 VAC Three Phase Wye 115% 80 kA 80 kA 120 kA 80 kA SG160K-240-3HLD 120/240 VAC Three Phase High Leg Delta 115% 80 kA 80 kA 120 kA 80 kA SG160K-480-3Y 277/480 VAC Three Phase Wye 115% 80 kA 80 kA 120 kA SG160K-480-3D 480 VAC Three Phase Delta 115% — 80 kA — UL 1449 Clamping Voltage (SVR) 6 kV, 500 Amp (8 x 20 usec)3 L-N L-G N-G L-L 160 kA 400 V 400 V 700 V 800 V 160 kA 400 V / (800 V) 400 V / (800 V) 700 V 800 V 80 kA 160 kA 800 V 800 V 1,500 V 1,500 V 80 kA 160 kA — 1,500 V — 2,500 V NOTES: 1 MCOV is Maximum Continuous Operating Voltage expressed in percent of nominal voltage. 2 Per Phase is defined as L-N + L-G for three phase 4-wire wye systems; L-G + L-L for three phase 3-wire delta systems. 3 Let-Through Voltage measured with 6 inch lead lengths per UL Standard 1449, 2nd Edition. The SG160 Series is a modular hardwired suppression device and recommended for all ANSI/IEEE Category locations. Contains one bolt-on module per phase for easy maintenance. Dimensions: 16"H x 14"W x 6"D Weight: 27 lbs. REPLACEMENT MODULE INFORMATION System Number: Quantity & Part Number SG160K-208-3Y (3) SG80-120V-M SG160K-240-3HLD (2) SG80-120V-M (1) SG80-240V-M SG160K-480-34 (3) SG80-277V-M SG160K-480-3D (3) SG80-480V-M WEATHERPROOF • ENERGY CONTROLS • PROFESSIONAL LIGHTING • POOL & SPA • SURGE PROTECTION • CONSUMER 109 Modular Protection System UG40 Series 90kA PER PHASE Features • All mode Protection (L-N, L-G, N-G, L-L) • Integral Disconnect • Redundant Protection per mode • Thermally Protected MOVs for maximum safety • UL1449, 2nd Edition, cULus • 10 year product warranty • Fault Current Tested to 200 KAIC • 200 KAIC Surge Rated Fuses • EMI/RFI Filtration – 20 to 30 dB from 20 kHz to 100 MHz • Replaceable Modules for low MTTR • NEMA 3R Style Enclosure • Complementary Listed as Secondary Surge Arrester (OWHX,E135626) Integral Diagnostics • LED Indicator Lights • Audible Alarm • Intermatic Thermal Monitoring System • Form C Contacts Surge Current Capacity (8 x 20 usec) (per mode) The UG40 Series is a modular hardwired suppression device and recommended for all ANSI/IEEE Category locations. Contains one module per phase for easy maintenance. Dimensions: 20.75"H x 10.75"W x 4.75"D Weight: 23 lbs. REPLACEMENT MODULE INFORMATION System Number: Quantity & Part Number UG40A2401S (2) UG41120A UG40A2083Y (3) UG41120B UG40A2403D (2) UG41120A (1) UG41208A UG40A2403G (3) UG41240A UG40A4803Y (3) UG41277A UG40A4803D (3) UG41480A 110 Per Phase2 MCOV1 Intermatic L-N L-G N-G L-L Model L-G UG40A2401S 120/240VAC Single Phase (split) 90 kA 45 kA 45 kA 45 kA 115% UG40A2083Y 120/208 VAC Three Phase Wye 115% 45 kA 45 kA 135 kA 45 kA UG40A2403D 120/240 VAC Three Phase High Leg Delta 115% 45 kA 45 kA 135 kA 45 kA UG40A2403G 240 VAC Three Phase Delta 115% — 90 kA — UG40A4803Y 277/480 VAC Three Phase Wye 115% 45 kA 45 kA 135 kA UG40A4803D 480 VAC Three Phase Delta 115% — 90 kA — UL 1449 Clamping Voltage (SVR) 6 kV, 500 Amp (8 x 20 usec)3 L-N L-G N-G L-L 90 kA 500 V 500 V 500 V 800 V 90 kA 500 V 500 V 500 V 700 V 90 kA 500 V / (800 V) 500 V / (700 V) 500 V 800 V 45 kA 125 kA — 700 V — 800 V 45 kA 90 kA 900 V 900 V 800 V 1,500 V 45 kA 135 kA — 1,500 V — 1,500 V NOTES: 1 MCOV is Maximum Continuous Operating Voltage expressed in percent of nominal voltage. 2 Per Phase is defined as L-N + L-G for three phase 4-wire wye systems; L-G + L-L for three phase 3-wire delta systems. 3 Let-Through Voltage measured with 6 inch lead lengths per UL Standard 1449, 2nd Edition. WEATHERPROOF • ENERGY CONTROLS • PROFESSIONAL LIGHTING • POOL & SPA • SURGE PROTECTION • CONSUMER Modular Protection System 90kA UG30 Series PER PHASE Features • All mode Protection (L-N, L-G, N-G, L-L) • Fault Current Tested to 200 KAIC • 200 KAIC Surge Rated Fuses • Redundant Protection per mode • EMI/RFI Filtration – 20 to 30 dB from 20 kHz to 100 MHz • Complementary Listed as Secondary Surge Arrester (OWHX,E135626) • Thermally Protected MOVs for maximum safety • Replaceable Modules for low MTTR • UL1449, 2nd Edition, cULus • NEMA 3R Style Enclosure • 10 year product warranty Integral Diagnostics • LED Indicator Lights • Intermatic Thermal Monitoring System Surge Current Capacity (8 x 20 usec) (per mode) Per Phase2 Intermatic MCOV1 Model L-G L-N L-G N-G L-L UG30A2401S 120/240 VAC Single Phase (split) 45 kA 90 kA 45 kA 115% 45 kA UG30A2083Y 120/208 VAC Three Phase Wye 115% 45 kA 45 kA 135 kA 45 kA UG30A2403D 120/240 VAC Three Phase High Leg Delta 115% 45 kA 45 kA 135 kA 45 kA UG30A2403G 240 VAC Three Phase Delta 115% — 90 kA — UG30A4803Y 277/480 VAC Three Phase Wye 115% 45 kA 45 kA 135 kA UG30A4803D 480 VAC Three Phase Delta 115% — 90 kA — UL 1449 Clamping Voltage (SVR) 6 kV, 500 Amp (8 x 20 usec)3 L-N L-G N-G L-L 90 kA 500 V 500 V 400 V 700 V 90 kA 500 V 500 V 400 V 700 V 90 kA 500 V / (700 V) 500 V / (700 V) 400 V 700 V 45 kA 135 kA — 700 V — 700 V 45 kA 90 kA 800 V 800 V 800 V 1,500 V 45 kA 135 kA — 1,500 V — 1,500 V The UG30 Series is a modular hardwired suppression device and recommended for all ANSI/IEEE Category locations. Contains one module per phase for easy maintenance. Dimensions: 12.88"H x 10.94"W x 4.65"D Weight: 15 lbs. NOTES: 1 MCOV is Maximum Continuous Operating Voltage expressed in percent of nominal voltage. 2 Per Phase is defined as L-N + L-G for three phase 4-wire wye systems; L-G + L-L for three phase 3-wire delta systems. 3 Let-Through Voltage measured with 6 inch lead lengths per UL Standard 1449, 2nd Edition. Flush Mount Plate UG1-FMP REPLACEMENT MODULE INFORMATION System Number: Quantity & Part Number UG30A2401S (2) UG29120A UG30A2083Y (3) UG29120A UG30A2403D (2) UG29120A (1) UG29208A (3) UG29240A UG30A2403G UG30A4803Y (3) UG29277A (3) UG29480A UG30A4803D WEATHERPROOF • ENERGY CONTROLS • PROFESSIONAL LIGHTING • POOL & SPA • SURGE PROTECTION • CONSUMER 111 Modular Protection System UG28 Series 90kA PER PHASE Features • Nine mode Protection (L-N, L-G, L-L) • Fault Current Tested to 200 KAIC • 200 KAIC Surge Rated Fuses • Redundant Protection per mode • EMI/RFI Filtration – 20 to 30 dB from 20 kHz to 100 MHz • Complementary Listed as Secondary Surge Arrester (OWHX,E135626) • Thermally Protected MOVs for maximum safety • Replaceable Modules for low MTTR • UL1449, 2nd Edition, cULus • NEMA 3R Style Enclosure • 10 year product warranty Integral Diagnostics • LED Indicator Lights • Intermatic Thermal Monitoring System The UG28 Series is a modular hardwired suppression device and recommended for all ANSI/IEEE Category locations. Contains one module per phase for easy maintenance. Dimensions: 12.88"H x 10.94"W x 4.65"D Weight: 15 lbs. Surge Current Capacity (8 x 20 usec) (per mode) Per Phase2 Intermatic MCOV1 Model L-G L-N L-G N-G L-L UG28A2401S 120/240 VAC Single Phase (split) 45 kA — 45 kA 115% 45 kA UG28A2083Y 120/208 VAC Three Phase Wye 115% 45 kA 45 kA — 45 kA UG28A2403D 120/240 VAC Three Phase High Leg Delta 115% 45 kA 45 kA — 45 kA UG28A4803Y 277/480 VAC Three Phase Wye 115% 45 kA 45 kA — UG28A4803D 480 VAC Three Phase Delta 115% — 90 kA — UL 1449 Clamping Voltage (SVR) 6 kV, 500 Amp (8 x 20 usec)3 L-N L-G N-G L-L 90 kA 500 V 500 V — 700 V 90 kA 500 V 500 V — 700 V 90 kA 500 V / (700 V) 500 V / (700 V) — 700 V 45 kA 90 kA 800 V 800 V — 1,500 V 45 kA 135 kA — 1,500 V — 1,500 V NOTES: 1 MCOV is Maximum Continuous Operating Voltage expressed in percent of nominal voltage. 2 Per Phase is defined as L-N + L-G for three phase 4-wire wye systems; L-G + L-L for three phase 3-wire delta systems. 3 Let-Through Voltage measured with 6 inch lead lengths per UL Standard 1449, 2nd Edition. Flush Mount Plate UG1-FMP REPLACEMENT MODULE INFORMATION System Number: Quantity & Part Number UG28A2401S (2) UG27120A (3) UG27120A UG28A2083Y (2) UG27120A UG28A2403D (1) UG27208A UG28A4803Y (3) UG27277A UG28A4803D (3) UG27480A 112 WEATHERPROOF • ENERGY CONTROLS • PROFESSIONAL LIGHTING • POOL & SPA • SURGE PROTECTION • CONSUMER Industrial Point-of-Use Protection F20 Series Features • All mode Protection • Thermally Protected MOVs for maximum safety • UL1449, 2nd Edition and UL1283 Listed, cULus • NEMA 4 Enclosure • EMI/RFI Filtration – 26 to 39 dB • 5 year product warranty Integral Diagnostics • LED Indicator Lights • Intermatic Thermal Monitoring System • Form C Contacts Surge Current Capacity (8 x 20 usec) (per mode) Intermatic MCOV1 Model L-G L-N L-G IG1201F20 120 VAC Single Phase 115% 16 kA 16 kA IG2401F20 240 VAC Single Phase 115% — 32 kA UL 1449 Clamping Voltage (SVR) 6 kV, 500 Amp (8 x 20 usec)3 N-G L-L Per Phase2 L-N L-G N-G L-L 16 kA — 32 kA 500 V 500 V 500 V — — 16 kA 48 kA — 700 V — 700 V NOTES: 1 MCOV is Maximum Continuous Operating Voltage expressed in percent of nominal voltage. 2 Per Phase is defined as L-N + L-G for three phase 4-wire wye systems; L-G + L-L for three phase 3-wire delta systems. 3 Let-Through Voltage measured with 6 inch lead lengths per UL Standard 1449, 2nd Edition. The F20 Series is a hardwired in line suppression device for protection of loads up to 20 Amps including fire alarm circuits, industrial controls, PLC’s and any other sensitive electronic equipment. Dimensions: 4.54"H x 3.5"W x 2.2"D Weight: 2.5 lbs. Din Rail Adapter Kit IG1DIN-F20 WEATHERPROOF • ENERGY CONTROLS • PROFESSIONAL LIGHTING • POOL & SPA • SURGE PROTECTION • CONSUMER 113 Industrial Point-of-Use Protection Features A B • Designed for heavy industrial use • 3-mode Surge Protection (L-N, L-G, N-G) • UL1449, 2nd Edition, cULus • EMI/RFI noise filtration A. IG11246 C • 4-outlets • 6 ft. cord • Lighted On/Off switch B. IG11466 D • 6-outlets • 6 ft. cord • Lighted On/Off switch • Enhanced EMI/RFI noise filtration, UL1283 F C. IG11266 E • 6-outlets • 6 ft. cord • Lighted On/Off switch D. IG11266BLK10 G • Black • 6-outlets • 10 ft. cord • Lighted On/Off switch H I E. IG2066 & IG20615 • 6 specification-grade outlets • Master On/Off switch • Enhanced EMI/RFI noise filtration, UL1283 • 6 ft. cord (IG2066); 15 ft. cord (IG20615) • 14 gauge SJT power cord with molded plug • Protection monitoring circuitry with LED light indicator • 15 amp resettable breaker • Ivory metal housing F. IG1866A • 6-outlets • 6 ft. cord • Audible alarm • Master On/Off switch • Enhanced EMI/RFI noise filtration, UL1283 G. IG20B12 & IG2012B15 • 6 specification-grade outlets • Master On/Off switch • Enhanced EMI/RFI noise filtration, UL1283 • 6 ft. cord (IG20B12); 15 ft. cord (IG2012B15) H. IG2086 • 8 specification-grade outlets • Master On/Off switch • Enhanced EMI/RFI noise filtration, UL1283 • 6 ft. cord I. IG9638S55 • 6 specification-grade outlets • Lighted On/Off switch • Steel housing • 15 ft. cord See chart on page 115 for UL1449 ratings and EMI/RFI filtration. Computer Control Centers Features • 6 centralized switches • One unswitched receptacle • Metal housing • Static discharge pad • 15 Amp, resettable circuit breaker J. IG141 • Standard model J K L M 114 K. IG141T • Standard model with phone/fax/modem protection • RJ11 connectors • 9 ft., 14 gauge power cord • LED Indicator Light monitors power on & protection status • L-N, L-G and N-G surge protection • cULus • UL1449, 2nd Edition L. IG143 • Enhanced EMI/RFI noise attenuation • Dual choke design for lower clamping M. IG143T • Enhanced model with phone/fax/modem protection • RJ11 connectors WEATHERPROOF • ENERGY CONTROLS • PROFESSIONAL LIGHTING • POOL & SPA • SURGE PROTECTION • CONSUMER Industrial Point-of-Use Protection Mounting Bracket & Plate N N. IG1SRMP • Allows any IG strip to be mounted on a 19" equipment rack O. 24EG5133 • Secures mounting bracket for all IG strips in extruded aluminum alloy housing (See models on chart with *) Product Selection Chart – Point of Use Models Energy Capacity UL1449 Clamping Number Max. Max. Connected Voltage (SVR) Intermatic of Cord Electrical Joule. Surge. Equipment 6 kV, 500A Model Outlets Length Rating Rating Amperage $ Coverage (8 x 20 µ sec) Industrial Grade L-N/L-G/N-G IG11246* 4 6 120 V/15 A 480 24,000 A $10,000 400/400/400 IG11266* 6 6 120 V/15 A 480 24,000 A $10,000 400/400/400 IG11266BLK10* 6 10 120 V/15 A 480 24,000 A $10,000 400/400/400 IG11466* 6 6 120 V/15 A 480 24,000 A $10,000 400/400/400 IG1866A* 6 6 120 V/15 A 960 48,000 A $25,000 330/330/330 IG2066* 6 6 120 V/15 A 960 48,000 A $25,000 330/330/330 IG20615* 6 15 120 V/15 A 960 48,000 A $25,000 330/330/330 IG20B12* 6 6 120 V/15 A 480 24,000 A $ 5,000 400/400/400 IG2012B15* 6 15 120 V/15 A 480 24,000 A $ 5,000 400/400/400 IG9638S55 6 15 120 V/15 A 480 24,000 A — 400/400/400 IG2086* 8 6 120 V/15 A 960 48,000 A $25,000 330/330/330 Computer Control Centers IG141 6 9 120 V/15 A 480 24,000 A $10,000 400/400/400 IG141T 6 9 120 V/15 A 480 24,000 A $10,000 400/400/400 IG143 6 9 120 V/15 A 960 48,000 A $25,000 330/330/330 IG143T 6 9 120 V/15 A 960 48,000 A $25,000 330/330/330 EMI-RFI Noise Filtration Prod. Frequency Max. Warr. Range (Hz) Reduc. (yrs) 100k-20M 100k-20M 100k-20M 100k-20M 100k-100M 100k-100M 100k-100M 100k-20M 100k-20M 100k-20M 100k-100M 25dB 25dB 25dB 40dB 62dB 62dB 62dB 25dB 25dB 21dB 62dB 5 5 5 5 5 5 5 5 5 5 5 100k-20M 100k-20M 100k-100M 100k-100M 25dB 25dB 62dB 62dB 5 5 5 5 O * = Extruded aluminum housing NOTE: Cord lengths can be modified up to 25 feet. Consult Factory for pricing and availability. WEATHERPROOF • ENERGY CONTROLS • PROFESSIONAL LIGHTING • POOL & SPA • SURGE PROTECTION • CONSUMER 115 Residential Hardwired Protection IG Series Features • Hardwired models provide greater capacity to handle surge energy (based on their close location to the service ground) compared to standard plug-in strips • Designed for 120/240 volt single or (split-phase) panels • Dual LED indicator(s) provides surge protection status on AC A A. IG1300-2T-1C • 120/240 VAC Single (Split) Phase • 6 Modes of Surge Protection (L1-N, L2-N, L1-G, L2-G, N-G, L1-L2) • Provides protection for 2 Telephone Lines (Analog Phone Line, Modem, or DSL) and 1 Coax Line (Cable TV, Cable Internet or Satellite TV) • UL 1449 Listed, 2nd Edition and UL497A Listed, cULus • NEMA 3R Raintight Enclosure for indoor or outdoor installations (9.38"H x 5.25"W x 4.0"D) • Tested to 65 kAIC per NEC Section 285 • 5 Year Product Warranty • $10,000 Connected Equipment Coverage • Complementary Listed as Secondary Surge Arrester (OWHX,E135626) B B. IG1300-4T-2C • 120/240 VAC Single (Split) Phase • 6 Modes of Surge Protection (L1-N, L2-N, L1-G, L2-G, N-G, L1-L2) • Provides protection for 4 Telephone Lines (Analog Phone Line, Modem, or DSL) and 2 Coax Lines (Cable TV, Cable Internet or Satellite TV) • UL 1449 Listed, 2nd Edition and UL497A Listed, cULus • NEMA 3R Raintight Enclosure for indoor or outdoor installations (9.38"H x 5.25"W x 4.0"D) • Tested to 65 kAIC per NEC Section 285 • 5 Year Product Warranty • $10,000 Connected Equipment Warranty (Appliances and Electronics) [5 year] • Complementary Listed as Secondary Surge Arrester (OWHX,E135626) C C. IG1240RC D • 120/240 VAC Single (Split) phase • 6 Modes of Surge Protection (L1-N, L2-N, L1-G, L2-G, N-G, L1-L2) • Green LED indicator provides status of protection; Red LED indicator indicates reduced protection • NEMA 4 plastic housing (5.65"H x 4.18"W x 3.33"D) • 5 year product warranty • UL Listed UL1449, 2nd edition, cULus • Tested to 65 kAIC per NEC Section 285 • $10,000 Connected Equipment Coverage (Appliances and Electronics) [5 year] • Complementary Listed as Secondary Surge Arrester (OWHX,E135626) IG1240FMP3 • Includes faceplate, screws and mounting bracket for IG1240RC D. IG3240RC Flush Mount Plates IG1240FMP3 IG3240FMP3 • 120/240 VAC Single (Split) phase • 6 Modes of Surge Protection (L1-N, L2-N, L1-G, L2-G, N-G, L1-L2) • Green LED indicator provides status of protection; Red LED indicator indicates reduced protection • NEMA 4 metal housing (6.28"H x 4.4"W x 3.25"D) • 10 year product warranty • UL Listed UL1449, 2nd edition, cULus • Tested to 65 kAIC per NEC Section 285 • $25,000 Connected Equipment Coverage (Appliances and Electronics) [5 year] • Complementary Listed as Secondary Surge Arrester (OWHX,E135626) IG3240FMP3 • Includes faceplate, screws and mounting bracket for IG3240RC 116 WEATHERPROOF • ENERGY CONTROLS • PROFESSIONAL LIGHTING • POOL & SPA • SURGE PROTECTION • CONSUMER Residential Hardwired Protection E. IG251 E • Handles up to 600 Amp service capacity • Enclosure size (6.0"H x 3.5"W x 3.0"D) • Epoxy encapsulation protects surge components from moisture, dirt and corrosion • 5 year product warranty • UL 1449 2nd edition listed as a Transient Voltage Surge Suppressor • 250 Volt MCOV for generator applications Intermatic Model Service Voltage Phase IG1300-2T-1C IG1300-4T-2C IG1240RC IG3240RC IG251 120/240 120/240 120/240 120/240 120/240 2 2 2 2 2 Leads # – Length 4 4 4 4 4 24 24 30 30 24 Gauge Wire Config. Peak Surge Current Per Phase/ System 14 14 14 14 12 L1, L2, N, GND L1, L2, N, GND L1, L2, N, GND L1, L2, N, GND L1, L2, N, GND 20 kA/60 kA 20 kA/60 kA 20 kA/60 kA 60 kA/180 kA 48 kA/115 kA UL 1449 Clamping Voltage (SVR) 6 kV, 500 Amp (8 x 20 µ sec) L-N L-G N-G L-L 400 400 400 330 600 400 400 400 330 — 400 400 400 330 — 700 700 700 600 1200 F Stand Alone Telephone / Modem / DSL Internet Lines F. IG2TM • Provides protection for 2 lines • Tip to Ground, Tip to Ring and Ring to Ground Modes • 40 kA surge protection per line • Gas Tube Protection 350 Volt DC Breakdown • UL497A • Nema 1 Type Enclosure Model Number IG2TM Application Lines Gauge Wire Configuration phone/modem/DSL up to 2 #24-#16 AWG 4 wire Application Lines Gauge Wire Configuration phone/modem/DSL up to 4 #24-#16 AWG 8 wire DC Breakdown Voltage Application 350 Vdc G Indoor G. IG4TM • Protection same as IG2TM • Protects 4 Lines Model Number IG4TM DC Breakdown Voltage Application 350 Vdc Indoor H. IG2T3R • Protection same as IG2TM • Provides protection for 2 lines (expandable to 12 Lines) • Nema 3R Type Enclosure Model Number IG2T3R Application phone/modem/DSL Lines Gauge H Wire Configuration 2 standard #24-#16 AWG 4 wire (up to 24 wire) (up to 12) DC Breakdown Voltage Application 350 Vdc Indoor/Outdoor WEATHERPROOF • ENERGY CONTROLS • PROFESSIONAL LIGHTING • POOL & SPA • SURGE PROTECTION • CONSUMER 117 Residential Hardwired Protection I Stand Alone Local Antenna/Cable - Satellite/Cable Internet Protection I. IG1CM • Provides Protection for 1 Line (Expandable to 2 Lines) • 10 kA surge protection per line • Gas Tube Protection 90 Volt DC Breakdown Application Lines Thread Type DC Breakdown Voltage Cable TV/internet/satellite 1 F 90 Vdc Application Indoor/Outdoor Model Number IG1CM J Application Indoor J. IG1C3R • Protection same as IG1CM • Provides Protection for 1 Line (Expandable to up to 6 Coax Lines) • Nema 3R Type Enclosure Model Number IG1C3R Application Lines Thread Type DC Breakdown Voltage Cable TV/internet/satellite 1 Standard (up to 6) F 90 Vdc K. IG2T • Spare Telephone / Modem / DSL Internet Protection Module K Model Number IG2T Spare Lines 2 For Use In: IG2TM, IG1CM, IG2T3R, IG1C3R, IG1300-2T-1C L. IG1C • Spare Coax Cable Protection Module Model Number IG1C Spare L Lines 1 For Use In: IG1CM, IG1C3R, IG2TM, IG4TM, IG2T3R M. IGFlush Mount Kit • Flush mount kit for IG2TM, IG4TM, and IG1CM Model Number IG Flush Mount Kit For Use In: IG2TM IG4TM, IG1CM M 118 WEATHERPROOF • ENERGY CONTROLS • PROFESSIONAL LIGHTING • POOL & SPA • SURGE PROTECTION • CONSUMER Surge Arresters A Features: • Designed for outdoor installations on service entrance and utility meter cabinets • Approved for outdoor applications such as irrigation equipment, pumps, lighting fixtures, traffic signaling devices, farm equipment, HVAC controls and motors • Parallel metal oxide varistors (MOV) from each line to grounded neutral provide increased product capability • Molded polycarbonate housing with 1/2" x 20 threaded nipple is weatherproof and UV resistant • Epoxy encapsulation protects components from moisture, dirt and corrosion • Color coded 18" leads • UL listed as a secondary surge arrester, ANSI/IEEE C62.11 for Category “C” locations “OWHX” • 2 year product warranty A. AG2401C • 120/240 single phase, 2 pole 3 wire device • 18" 14 gauge leads B. AG2083C • 120/208 VAC, 3 pole 4 wire device • 18" 12 gauge leads C • Up to 600 V three phase, 3 pole 4 wire device • 18" 12 gauge leads (AG6503); 36" 10 gauge leads (AG6503L) D E G. AG2401C-IND • 120/240 single phase, 2 pole 3 wire device • 18" 14 gauge leads D. AG4803C • 277/480 VAC or 480 VAC, 3 pole 4 wire device • 18" 12 gauge leads Standard (No LED’s) AG2401C 120/240V AG2083C 208V AG2403C 240V AG4801 277V or 480V AG4803C 480V AG6503C Up to 600V AG6503L Up to 600V Enhanced (with LED‘s) AG2401C-IND 120/240V AG6503C-IND Up to 600V AG6503L • 277V or 480V VAC single phase, 2 pole 3 wire device • 18" 10 gauge leads • 18" 6 gauge green ground lead • 240 VAC, 3 pole 4 wire device • 18" 12 gauge leads Service Voltage B F. AG4801 C. AG2403C Model E. AG6503C & H. AG6503C-IND • Up to 600 V three phase 3 pole 4 wire device • 18" 12 gauge leads Poles Number of Leads/ Length Wire Configuration 1 or 2 3 3 1 or 2 3 3 3 3/18" 4/18" 4/18" 3/18" 4/18" 4/18" 4/36" L1, L2, GND/N L1, L2, L3, GND/N L1, L2, L3, GND/N L1, L2, GND L1, L2, L3, GND/N L1, L2, L3, GND/N L1, L2, L3, GND/N 1500A 490 490 740 1450 1450 1640 1640 5000A 980 980 1330 2130 2130 2340 2340 10000A 1410 1410 1850 2620 2620 2920 2920 1 or 2 3 3/18" 4/18" L1, L2, GND/N L1, L2, L3, GND/N 490 1640 980 2340 1410 2920 F Actual Clamping Voltage (Line to Ground) Match the correct model to the voltage of your system/machine G H The chart below shows Typical Clamp Voltage for each model. Mounting Bracket AG1BRKT WEATHERPROOF • ENERGY CONTROLS • PROFESSIONAL LIGHTING • POOL & SPA • SURGE PROTECTION • CONSUMER 119 Surge Arresters A. UG240R B. IG250LA • 120/240 V Surge Arrester for up to 600 Amp service • 2 pole 3 wire configuration for installation on utility cabinets and outdoor service panels • Enclosure size (6.0"H x 3.5"W x 3.0"D) • Steel weatherproof housing with lockable cover • Epoxy encapsulation protects components from moisture, dirt and corrosion • UL listed as a Secondary Surge Arrester (OWHX) • LED indicator provides surge protection status • 5 year product warranty A B • 120/240 V Surge Arrester for up to 600 Amp service • Designed for applications frequently subjected to high level surge energy • Enclosure size (6.63"H x 3.75"W x 2.5"D) • Epoxy encapsulation protects components from moisture, dirt and corrosion • UL listed as a Secondary Surge Arrester (OWHX) • LED indicator provides surge protection status • 5 year product warranty Number Peak Surge Current of 24" Wire Per Phase/ Leads Configuration Per System Model Service Voltage Phase UG240R 120/240 2 3 L1, L2, N 48 kA/115 kA IG250LA 120/240 2 3 L1, L2, N 48 kA/115 kA Clamping Voltage @500A Enclosure Size (inches) Weight Lbs L-N: 555 L-L 1028 L-N: 555 L-L: 1028 6.06 x 3.81 x 3.31 2.4 6.0 x 3.5 x 3.0 2.4 Surge Protection Device Connected Equipment Coverage Surge Protection devices, with Connected Product Type Metal Multi-Outlet Strip Page # 114 Model Number IG2012B15 IG20B12 Metal Multi-Outlet Strip Computer Control Center Residential Grade Protector 114 114 116 117 118 114 114 114 116 IG11246 IG141 IG1240RC IG2TM IG1CM IG1866A IG2066 IG143 IG3240RC Equipment Coverage, offers the user extended protection for sensitive equipment. In the Metal Multi-Outlet Strip unlikely event that a damaging transient surge passes through the surge device and damage Computer Control Center Residential Grade Protector IG11266 IG141T IG1300-2T-1C IG4TM IG1C3R IG2046 IG2086 IG143T Maximum Repair or Replacement Coverage IG11466 IG1300-4T-2C IG2T3R occurs to the connected equipment, Intermatic will pay up to $25,000 to repair or replace the equipment based on the specified model and coverage provided. Refer to the warranty document included with the product for specific coverage details and limitations. 120 WEATHERPROOF • ENERGY CONTROLS • PROFESSIONAL LIGHTING • POOL & SPA • SURGE PROTECTION • CONSUMER R CONSUME S T C U D O R P 121 Entering a New Century of Energy Management and Home Security! Indoor and Outdoor Timers Intermatic offers a wide variety of styles to meet today’s application requirements. Intermatic timers add convenience by turning lights ON when needed, and saves energy by turning lights OFF when not needed. They give homes a lived-in look providing an easy and economical way to improve home security. Outdoor timers also let users control outside lights and holiday displays while staying comfortably inside. Heavy Duty Outdoor Timers for lights, motors & pool pumps Digital Photo Control automatically turns lights on at dusk, off 6 hours later Do-it-yourself Wireless Motion Sensor Alarms Home Controls, Modules and controllers Power Failure Lights & Photo Controls Intermatic power failure lights have many practical applications in the home: in bedrooms, hallways, stairways, bathrooms, kitchens and more. Photo controls are a simple solution to turning lights on when dark, off when light. Do-it-Yourself Security Alarms The Burglary Prevention Council statistics show that residential break-ins occur every 11 seconds. Intermatic answers the demand for easy-to-install, affordable security products with a full line of DIY portable security alarms that have superior features. Intermatic Wireless Alarms provide economical home security. There are no monthly fees or setup charges. The wireless feature offers easy do-ityourself installation at affordable prices. 122 Outdoor Digital Timers with light sensor to control outdoor lights & holiday displays Heavy-Duty Digital 7-Day Wall Switch Timers to control fans, lights & appliances with “never set it again” feature All purpose Heavy-Duty Lamp & Appliance Timers 24 Hr. Heavy-Duty Programmable Digital Timer for lamps, stereos, & appliances WEATHERPROOF • ENERGY CONTROLS • PROFESSIONAL LIGHTING • POOL & SPA • SURGE PROTECTION • CONSUMER Intermatic Home Controls A Until now, the ability to reliably and cost efficiently control lighting and electronics and electrical devices in the home, using Radio Frequency, was extremely limited. Intermatic introduces a line of cost effective plug-in modules, in-wall receptacles and switches and easy-to-use controllers that allow fingertip control of multiple items in and around the house. Intermatic’s Home Controls incorporate Z-Wave™ technology – the most advanced, low cost and highly efficient Radio Frequency based technology in the industry. Innovative Features: • All items are controlled by Radio Frequency (no wiring is involved) • Easy DIY installation • All products use unique Z-Wave™ technology • Two-way feedback lets you know if the system is properly set up and if the system is working properly • The cost for this highly reliable system is priced much less than comparable systems that require contractor installation • All modules and in-wall products can be set for timing control • Each module includes a “repeater” function, for unmatched reliability • Controllers can control up to 192 devices and can create “scenes” to create the light level look wanted A. HA01C Wall Receptacle • Replaces standard wall receptacles • One receptacle is controlled • LED shows feedback from controller during setup and that the controlled device is working • Use with decora wall plate (not included) Specifications: • For indoor use only • 15 Amps Resistive • 8.3 Amps Tungsten • 120VAC, 60 Hz • Temperature operating range: 0°C to 60°C B C. HA03C Plug-In Indoor Lamp Module • Controls ON/OFF/DIM for incandescent lamps • Manual override • LED shows feedback from controller during setup and that the controlled device is working C Specifications: • For indoor use only • 300 Watts • 120VAC, 60 Hz • Temperature operating range: 0°C to 60°C D B. HA02C Plug-In Appliance Module • Controls appliances up to 15 Amps and lighting (including compact fluorescent bulbs) • Heavy-duty 3 prong plug and receptacle • Manual override • LED shows feedback from controller during setup and that the controlled device is working Specifications: • For indoor use only • 15 Amps Resistive • 1200 W Inductive • 1/2 HP • 8.3 Amps Tungsten • 120VAC, 60 Hz • Temperature operating range: 0°C to 60°C D. HA04C Outdoor Lighting Module • Controls ON/OFF outdoor devices • Weather resistant • 6" cord • Manual override • LED shows feedback from controller during setup and that the controlled device is working Specifications: • 15 Amp Resistive • 1/2 HP • 1200 W Inductive • 8.3 Amp Tungsten • 120 VAC, 60 Hz • Temperature operating range: -35°C to 60°C WEATHERPROOF • ENERGY CONTROLS • PROFESSIONAL LIGHTING • POOL & SPA • SURGE PROTECTION • CONSUMER 123 Intermatic Home Controls E E. HA05C Outdoor Lamp Screw-In Module • For incandescent and PAR lamps • Fits most outdoor fixtures • ON/OFF functions • Manual override • LED shows feedback from controller during setup and that the controlled device is working Specifications: F • 300 W Tungsten, 4 W compact fluorescent • 120 VAC, 60 Hz • Temperature operating range: -35° C to 60° C F. HAO6C Indoor Wall Switch • Rocker style uses decorative wall plate (not included) • ON/OFF/DIM controls • Manual override • LED shows feedback from controller during setup and that the controlled device is working Specifications: G • For indoor use only • 300 Watts Tungsten • 120 VAC, 60 Hz • Temperature operating range: 0°C to 70°C G. HA07 Master Remote Controller • Controls all Intermatic Home Settings devices • Large LCD screen shows all functions when set-up is successful, dim levels, channels and time functions • Easy to set up • Attractive design can be set on a table or wall mounted • ALL ON/ALL OFF buttons controls devices to warn would-be intruders • Controls up to 12 channels • Each channel can control up to 16 devices • Timing controls for all devices include: - Set the Astronomic feature and you will never have to reset the timer for the everyday changes in SUNRISE and SUNSET times. - Multiple time options: all week, 5 days, weekends or individual days - RANDOM timing option for a “lived-in” look - Optional automatic Daylight Savings Time function • 8 dimming levels • Requires 4 AA batteries (not included). Specifications: • Temperature operating range: 0°C to 60°C H. HA09C Handy Remote Control • Controls all Intermatic Home Controls devices • Easy to set up • Attractive, easy to hold • Controls up to 6 channels • Each channel can control up to 16 devices • 8 dimming levels • Requires 4 AAA batteries (not included) Specifications: • Temperature operating range: 0°C to 60°C H 124 WEATHERPROOF • ENERGY CONTROLS • PROFESSIONAL LIGHTING • POOL & SPA • SURGE PROTECTION • CONSUMER Indoor Plug-In Timers Heavy Duty Lamp & Appliance Timers A. TN111C Lamp & Appliance Timer D. TN711C Random Pattern Security Timer • 2 ON / 2 OFF settings per day • Controls lamps & appliances • Ideal for all-purpose use • Ratings: 15 Amp Resistive, 1750 Watts Tungsten, 1/3 HP, 125 VAC, 60 Hz B. TN111GC Lamp & Appliance Timer With Lighted Dial • 2 on/2 off settings per day • Turns lights on and off automatically within ±15 min. of the set times • Eliminates the predictable “timer-controlled” look • Ratings: 15 Amp Resistive, 1750 Watts Tungsten, 1/3 HP, 125 VAC, 60 Hz E. TN311C Heavy-Duty Grounded Timer Override switch with on/off indicator faces up - easiest to view and change Oversized color-coded trippers simplest to use • 3 on/3 off settings per day • For air conditioners, heaters and other heavy electrical loads • Ratings: 15 Amp Resistive, 1750 Watts Tungsten & Resistive, 125 VAC, 60 Hz, 12 FLA, 72 LRA, 120 VAC Motor (12 AMP Air Conditioner) • Transparent plastic dial acts as a night light • 2 ON / 2 OFF settings per day • Ideal for all-purpose use • Ratings: 15 Amp Resistive, 1750 Watts Tungsten, 1/3 HP, 125 VAC, 60 Hz Unique “time of day” window quickest and easiest to set B A C. TN811C Multi-Setting Timer C D • 24 ON / 24 OFF settings per day • Convenient programmable settings • Enhances safety & security by making home look more “lived-in” • Ratings: 15 Amp Resistive, 1750 Watts Tungsten, 1/3 HP, 125 VAC, 60 Hz E Digital Plug-in Timers F. DT17C 7-Day Heavy-Duty Digital Timer • Up to 14 ON / 14 OFF settings per day or 98 ON / 98 OFF settings per week • Random setting option avoids predictable “timercontrolled” look • 3-prong grounded plug and receptacle • Controls lamps (including fluorescent), TVs, stereos and appliances • Easy-to-set hand-held programming with battery backup • Manual override feature • Ratings: 15 Amp Resistive & Inductive, 500 Watts Tungsten, 1/3 HP 120 VAC H. DT27C Heavy-Duty Digital Timer with Astronomic Feature • Up to 7 ON/OFF settings per day • Astronomic features allow setting it once without ever having to reset it again; follows daily changes in sunrise/sunset times • Random setting option avoids predictable “timercontrolled” look • 3-prong grounded plug and receptacle • Controls lamps (including fluorescent), TVs, stereos and appliances • Easy to program • Battery backup • Manual override feature • 15 Amp Resistive and Inductive, 500 Watts Tungsten, 1/3 HP, 120 VAC, 60 Hz G. DT121C Digital Lamp Timer • 2 ON / 2 OFF settings per day • Controls indoor lamps • To-the-minute accuracy • Large display, easy to read • Manual override feature • Ratings: 8.3 Amp Resistive and Inductive, 300 Watts Tungsten, 120 VAC, 60 Hz I. F G TB121C Digital Table Top Timer • 2 ON / 2 OFF settings per day • Attractive tabletop styling in decorative platinum • 5 ft. cord • Easy to reach • Large display, easy to read • To-the-minute accuracy • Manual override feature • Ratings: 8.3 Amp Resistive and Inductive, 300 Watts Tungsten, 120 VAC, 60 Hz H I WEATHERPROOF • ENERGY CONTROLS • PROFESSIONAL LIGHTING • POOL & SPA • SURGE PROTECTION • CONSUMER 125 Appliance & Wall Switch Timers Heavy Duty Appliance Timers A. HB112C Air Conditioner & Appliance Timer C. HB113C Air Conditioner & Appliance Timer Same as HB112C except 2500W/120V/ for the following: 1 H.P. 120V Max. • Automatically controls 120 Volt Motor Load air conditioners, heaters, heavy-duty appliances and lamps • 2,500 Watt capacity • Automatically controls 240 volt 3750W/240V/ air conditioners, heaters, 2 H.P. 240V Max. heavy-duty appliances Motor Load and lamps • 3,750 watt capacity • Plugs directly into wall outlet • 2 ON/2 OFF settings per day • 3-prong 220-240 Volt grounded plug and receptacle • Manual override ON/OFF switch A, B, C D B. HB114C Air Conditioner & Appliance Timer E • Same as HB112C except for the following: • 5,000 Watt capacity 5000W/240V/ 2 H.P. 240V Max. Motor Load Wall Switch Timers D. ST01C Heavy Duty In-Wall Timer with Astronomic Feature Can be used with four separate programming options: Same settings Monday through Friday, Saturday & Sunday, all 7 days of the week or individual daily settings. F G H • DST for 2006, 2007 and flexible for future changes, if needed • Set it once and never set it again; follows daily changes in sunrise/sunset times • For single pole and three way applications up to 100 ft. • Controls lighting including fluorescent and heavy duty loads such as fans and appliances • Up to 6 ON/OFF settings per 7-day period a total of 42 ON/42 OFF settings per week • Easy-to-set 6 button programming • LCD digital clock and readout • To-the-minute setting accuracy • Battery backup • Random setting feature available to avoid predictable “timer controlled” look • Manual override feature • Use with decorator-style wall plate (not included) • Ratings: Resistive: 15 A, 120-277 VAC Tungsten: 15 A, 120 VAC, 6 A, 208-277 VAC Ballast: 8 A, 120 VAC, 4 A, 208-277 VAC Motor: 1 HP, 120 VAC, 2 HP, 240 VAC DC Loads: 4 A, 12 VDS, 2 A, 28 VDS E. ST01AC Heavy Duty In-Wall Timer with Astronomic Feature F. EJ351C Programmable 24-hour Security Timer • Up to 24 ON/24 OFF settings per day • Random setting turns light ON and OFF at slightly different times each day • Self-learning feature: if not manually programmed, it will repeat the first 24 hr. ON/OFF pattern • 15 minute memory guard protects against power failure • Replaces any standard wall light switch • Use with existing wall plate; standard (toggle) or decorator (rocker) styles • Ratings: 500 Watts Incandescent, 120 VAC, 60 Hz G. EJ500C Indoor Digital Wall Switch Timer with Astronomic Feature • Flushmount design • 6 ON/6 OFF settings per day • Controls incandescent and fluorescent (class “P” ballast) lighting • Easy to set programming • Set it once and never set it again; follows daily changes in sunrise/sunset times • Battery backup guards against memory loss • Replaces any standard wall switch • Use with decorative style wall plate(not included) • Ratings: 500 Watts Incandescent, 120 VAC, 60 Hz H. EJ500AC Indoor Digital Wall Switch Timer with Astronomic Feature Same as EJ500C except Almond Color Same as ST01C except Almond color 126 WEATHERPROOF • ENERGY CONTROLS • PROFESSIONAL LIGHTING • POOL & SPA • SURGE PROTECTION • CONSUMER Outdoor Timers A. HB31R Heavy Duty Outdoor Timer (15 Amp) C. HB51RC Outdoor Timer with Light Sensor • Highly versatile control with choice of operating modes • Photo ON / Timer OFF mode provides automatic ON at dusk, OFF after owner’s choice on 2, 4, 6 or 8 hours • Photo ON / Photo OFF mode offers automatic ON at dusk, OFF at dawn • 8.3 Amp lighting timer • Manual override ON/OFF switch • Grounded, compact 6" cord • Up to 2 ON / 2 OFF settings per day • Full 15 Amp capacity controls lighting and heavy-duty loads such as motors and pool pumps • Grounded plug • Manual override ON/OFF switch • Waterproof cover • Heavy-duty 12" grounded cord • 120 VAC, 60 Hz B. HB35R Outdoor Timer (10 Amp) D. HB61RC Digital Outdoor Timer with Light Sensor • 2 ON / 2 OFF settings per day • Grounded plug • Manual override ON/OFF switch • Waterproof cover • Heavy-duty 15" cord • 120 VAC, 60 Hz • Photo ON at dusk, OFF at dawn • Photo ON at dusk, OFF at 1 hour increments from 1-9 hours • Immediate ON/OFF at owner’s selection in 1 hour increments for 1-9 hours • Manual override • Grounded 6" cord and receptacle Model Number Max. ON Time Min. ON Time HB31R 23-1/2 hrs. 1/2 hr. HB35R 23-1/2 hrs. 1/2 hr. HB51RC Dusk to 8 hr. Dusk to 2 hr. HB61RC Dusk to 8 hr. Dusk to 2 hr. A B Capacity 15 Amps, 1800 Watts Resistive; 15 Amps, 1800 Watts Tungsten, 15 FLA, 90 LRA; 120 VAC Operating Temp.: -40˚C to +40˚C 10 Amps, 1200 Watts Resistive; 10 Amps, 1200 Watts Tungsten; 120 VAC Operating Temp.: -40˚C to +40˚C 8.3 Amps, 1000 Watts Resistive; 8.3 Amps, 1000 Watts Tungsten, 120 VAC Operating Temp.: -35˚C to +40˚C 8.3 Amps, 1000 Watts Resistive; 8.3 Amps, 1000 Watts Tungsten, 120 VAC Operating Temp.: -35˚C to +40˚C C D WEATHERPROOF • ENERGY CONTROLS • PROFESSIONAL LIGHTING • POOL & SPA • SURGE PROTECTION • CONSUMER 127 Outdoor Timers E E. HB77R Digital Outdoor Timer G. HB88RC Programmable Outdoor Timer • 15 Amp capacity controls lighting and heavy-duty loads such as motors and pool pumps • 14 ON / OFF settings per day - a total of 42 ON / OFF settings per week - can be used with 4 separate programming options – Same settings Monday through Friday – Same settings Saturday and Sunday – Same settings all 7 days of the week – Various daily settings • Easy hand-held programming • Replaceable button cell batteries (included) maintains program, during power failure F. • 15 Amp capacity controls lighting and heavy duty loads such as engine block heaters, holiday and landscape lighting, pool/spa pumps and more • 7 day / 7 event programming • Multiple daily programming options – Same settings Monday through Friday – Same settings Saturday and Sunday – Same settings all 7 days of the week – Individual daily settings • Two timed receptacles • Battery backup • Ratings: 15 Amp Resistive and Tungsten, 1000W Inductive, 1/2 HP, 120 VAC, 60 Hz HB1116R 6 Outlet Electromechanical Timer with Stake • 2 ON/OFF settings per day • Full 15 Amp capacity controls lighting and heavy loads such as motors, engine block heaters and pool pumps • Weatherproof cover • 24" grounded cord • Grounded receptacle • Circuit breaker • Manual override ON/OFF switch • For wall mounting or stake mounting F Model Number Max. ON Time Min. ON Time HB77R 6 days 23 hrs. 59 min. 23-1/2 hrs. 1 min. 6 days 23 hrs. 59 min. 1 min. HB1116R HB88RC 1/2 hr. Capacity 15 Amps Resistive and Inductive, 500 Watts Tungsten, 1/3 H.P., 120 VAC Operating Temp.: -35˚C to +40˚C 15 Amps, 1800 Watts Resistive; 15 Amps 1800 Watts Tungsten 15 FLA, 90 LRA, 120 VAC Operating Temp.: -40˚C to +40˚C 15 Amps, 1000 Watts Resistive; 15 Amps 1000 Watts Tungsten 1/2 HP; 120 VAC; 60 Hz G 128 WEATHERPROOF • ENERGY CONTROLS • PROFESSIONAL LIGHTING • POOL & SPA • SURGE PROTECTION • CONSUMER Photo Controls Power Failure Light Safety Light Products A. NE1C Screw-In Photo Control D. NE200C Plug-In Photo Control • Automatically turns electrical load ON at dusk, OFF at dawn • Screws into any standard incandescent light socket • Controls interior and exterior lights B. NE2C Automatic Security Light Dual Photo Cell with Flicker Eliminator • Automatically turns electrical load ON at dusk, OFF at dawn • Advanced technology circuit saves energy • Screws into any standard incandescent light socket • Controls interior and exterior lights C. NE3BC Digital Photo Control, Time Controlled • Automatically turns electrical load ON at dusk, OFF at dawn • For outdoor spot and flood lamps, used on driveways and patios • Also ideal for indoor or outdoor PL lamp fixtures (compact fluorescent) B E. NE250C Outdoor Photo Control • Automatically turns electrical load ON at dusk, OFF at dawn • For outdoor spot and flood lamps, used on driveways and patios • Handles up to 150 Watt incandescent bulbs F. • Automatically turns light ON at dusk and OFF 6 hours later • Soft start extends bulb life • Controls incandescent lights up to 150 Watts • Screw into any standard incandescent light socket • Controls indoor and exterior lights • Handles up to 150 Watt incandescent and 45 Watt fluorescent bulbs A C NE5C Plug-In Photo Control • Automatically turns electrical load ON at dusk, OFF at dawn • Plugs into any polarized indoor wall socket • Controls indoor devices such as table light, floor light, radio or TV E D F Power Failure Light G. PR3C 3-in-1 Power Failure Light • Light automatically comes on when power goes out • Automatic guide light • Can be used as a handy rechargeable flashlight • Screw-off cover with replaceable #14 flashlight bulb • Plugs into any polarized indoor wall socket • Provides safety and security • Unique receptacle for plugging in additional lamp or appliance • 120 Volts, 60 Hz, 1 Watt G WEATHERPROOF • ENERGY CONTROLS • PROFESSIONAL LIGHTING • POOL & SPA • SURGE PROTECTION • CONSUMER 129 Intermatic Do-It-Yourself Security Security Alarms A A. SP230B Wireless Alarm with Motion Sensor • Place on wall, table or shelf • Piercing alarm activated when movement is detected • Warning sticker included • Programmable code entered on keypad activates/deactivates alarm • 110 dB siren B. SP130B Wireless Door Alarm with Programmable Keypad B • Piercing alarm activated when contact point is broken • Mounts on door • Code entered on keypad activates/deactivates alarm • 110 dB siren C. SP440B Wireless Window Alarm • Piercing alarm activated when contact point is broken • Mounts on window • ON/OFF switch activates/deactivates alarm • 90 dB siren D. SP500 Window Stickers • Discourages intruders • 4 pack E. SP640B Personal Security Alarm • Piercing alarm sounds when pin is removed • Small enough to hold in the palm of the hand • Alerts others that help is required • Includes flashlight and belt clip • 90 dB siren C E D 130 WEATHERPROOF • ENERGY CONTROLS • PROFESSIONAL LIGHTING • POOL & SPA • SURGE PROTECTION • CONSUMER Malibu Low Voltage Landscape Lighting ® Malibu®, the leading landscape lighting brand, has been making lighting systems to enhance the beauty, safety and security of American homes for almost 40 years. In that time we’ve learned a lot about how American consumers use their outdoor space, and we’ve seen the definition of “outdoor lifestyle” grow. People spend more time outdoors than ever before, and it’s important to them to decorate their outdoor space. Malibu® helps them make their outdoors as beautiful, livable and enjoyable as their indoors. Fixtures For Every Need The traditional approaches to outdoor lighting are to provide uplight, to highlight trees or bushes and create a focal point for beauty; downlight to place along walkways and steps or outline driveways for safety; and backlight to illuminate walls or fences and light up a home’s exterior for security. To fill these needs, Malibu® offers a wide variety of floodlights and decorative fixtures, path and garden lights. Traditional lighting approaches are still very relevant today, but the trend that expands gracious living to a home’s outdoor space has led to a new approach, the creation of outdoor decorative elements that provide function and beauty in the daytime, as well as illumination at night. These items include an illuminated birdbath, lighthouse and rock spotlights. Lighting the way to outdoor living 12 volt fixtures provide important benefits not available with conventional 110 volt systems • Fast, easy installation • Flexibility to add and adjust fixtures as landscape matures • Economical operation, thanks to longer lamp life & less energy usage • No hard wiring required • No need for junction box on each fixture • Maximum eye appeal both night (when on) & day Market Leading Power Packs and Accessories (when off) Malibu® high quality Power Packs offer dependable power and integrated Intermatic timers to ensure that your customers’ landscape lighting delivers bright reliable light in any weather, year in and year out. Malibu® bulbs and cable complete the picture to give you safe, weather-resistant installations. ® Malibu Products are Affordable and Guaranteed Malibu® is committed to building the best products available across several price ranges. We also offer one of the most comprehensive warranties in the industry; from 3 years to lifetime depending on the fixture, and 5 years on Power Packs. For more information and to view the most up-to-date listing of Malibu® Landscape Lighting products, see our Landscape Lighting catalog, or visit our web site at www.intermatic.com. WEATHERPROOF • ENERGY CONTROLS • PROFESSIONAL LIGHTING • POOL & SPA • SURGE PROTECTION • CONSUMER 131 Malibu Low Voltage Landscape Lighting ® 132 CS110P CS110TA CS120TA CS14P Metal Walk Light with 11W wedge base bulb and Pewter finish Metal Walk Light with 11W wedge base bulb and Architectural Bronze finish Metal Walk Light with 18W wedge base bulb and Architectural Bronze finish Metal Carriage Light with 11W wedge base bulb and Pewter finish CS17K CS140K CS180C CS200C Metal Mission Light with 11W wedge base bulb and Antique Copper finish Metal Lantern Light with 18W wedge base bulb and Antique Copper finish Copper Floodlight with 20W halogen MR16 bulb Copper Tier Light with 18W wedge base bulb CS230R CS240 CS330OB CS508K Metal Mission Light with 18W wedge base bulb and Aged Brass finish Metal Parfait Light with 18W wedge base bulb and Aged Brass finish Metal Walk Light with 11W wedge base bulb and Oiled Bronze finish Metal floodlight with 35W halogen MR16 bulb and Antique Copper finish WEATHERPROOF • ENERGY CONTROLS • PROFESSIONAL LIGHTING • POOL & SPA • SURGE PROTECTION • CONSUMER Malibu Low Voltage Landscape Lighting ® CS508P CS508S CS508TA CS7AC1 Metal floodlight with 35W halogen MR16 bulb and Pewter finish Metal floodlight with 35W halogen MR16 bulb and Sand finish Metal floodlight with 35W halogen MR16 bulb and Architectural Bronze finish Metal garden light with 11W wedge base bulb and Antique Copper and Oil Rubbed bronze finish CS7CT4 CS7E1 NA320 NA401 Metal garden light with 4W wedge base bulb and Black finish Metal garden light with 4W wedge base bulb and Black finish Natural Rock Light with 20W MR11 bulb Metal Birdbath Light with 35 watt MR16 bulb and Verdigris finish NA501 Metal Hanging Floral Basket Light with 7 watt wedge base bulb and Verde finish WEATHERPROOF • ENERGY CONTROLS • PROFESSIONAL LIGHTING • POOL & SPA • SURGE PROTECTION • CONSUMER 133 Malibu Low Voltage Landscape Lighting ® Finishes & Colors Choose from classic or contemporary designs in a variety of finishes and textures. Use Malibu® fixtures to blend into your landscape design, add an elegant touch to a garden path or highlight architecture for safety and security. Aged Brass Antique Copper (K) Architectural Bronze (TA) Black Chrome (BC) Black Satin Bronze (BSB) Brushed Nickel (N) Copper (C) Graphite (GR) Oil Rubbed Bronze (OB) Pewter (P) Rustic Brick (RB) Sand (S) Verde (V) Verde Patina (V) CL1 CL111R CL115 CL191 Metal floodlight with 50W halogen MR16 bulb and Black finish Well Light with 11W Poly-Star bulb and Black finish Submersible Light with 20W halogen MR16 bulb and Black finish Metal Tier Light with 11W wedge base bulb and Black finish CL191K CL191S CL191V CL280 Metal Tier Light with 11W wedge base bulb and Antique Copper finish Metal Tier Light with 11W wedge base bulb and Sand finish Metal Tier Light with 11W wedge base bulb and Verde finish Metal Tulip Light with 18W wedge base bulb and Black finish CL305P CL4 CL501 CL503TA Metal Walk Light with 11 watt wedge base bulb and Pewter finish Metal Hanging Lantern with 7W wedge base bulb and Black finish Metal Well Uplight with 35 watt MR16 bulb and Black finish Metal Surface Light with 7 watt wedge base bulb and Architectural Bronze finish Verdigris Due to Intermatic’s dedication to technological advancement, it is possible that specifications and/or appearances of our products may have changed after the printing of this literature. See price list for the latest available product light sets. 134 WEATHERPROOF • ENERGY CONTROLS • PROFESSIONAL LIGHTING • POOL & SPA • SURGE PROTECTION • CONSUMER Malibu Low Voltage Landscape Lighting ® CL507 CL508 CL509 CL635R Metal Floodlight with 20W halogen MR16 bulb and Black finish Metal Floodlight with 35W halogen MR16 bulb and Black finish Metal Wall Wash Floodlight with 20W halogen bi-pin bulb and Black finish Metal Bollard Light with 20W MR11 bulb and Black Finish CL635P CL635RS CL635RK CL711 Metal Bollard Light with 20W MR11 bulb and Pewter finish Metal Bollard Light with 20W MR11 bulb and Sand finish Metal Bollard Light with 20W MR11 bulb and Antique Copper finish Metal Mushroom Light with 10W halogen bi-pin bulb and Black finish CL801BC8 CL802BSB6 CL802P7 CL803S2 Metal garden light with 4 and 11W wedge base bulbs, Black Chrome finish and Frosted Crackel Glass Globe Metal garden light with 4 and 11W wedge base bulbs, Black Satin Bronze finish and Mocha Marble Glass Globe Metal garden light with 4 and 11W wedge base bulbs, Pewter finish and Square Frosted Glass Globe Metal garden light with 4 and 11W wedge base bulbs, Sand finish and Frosted Ribbed Glass Globe WEATHERPROOF • ENERGY CONTROLS • PROFESSIONAL LIGHTING • POOL & SPA • SURGE PROTECTION • CONSUMER 135 Malibu Low Voltage Landscape Lighting ® 136 CL8041 CL9 CL9S CL905 Metal garden light with 4 and 11W wedge base bulbs, Black finish and Alabaster-Style Glass Globe Metal Floodlight with 20W halogen bi-pin bulb and Black finish Metal Floodlight with 20W halogen bi-pin bulb and Sand finish Metal Half Brick Light with 7W wedge base bulb and Black finish CL905K LT8 LT8K LT9 Metal Half Brick Light with 7W wedge base bulb and Antique Copper finish Metal Surface Light with 7W wedge base bulb and Black finish Metal Surface Light with 7W wedge base bulb and Antique Copper finish Metal Floodlight with 10W halogen bi-pin bulb and Black finish LT10 LT13 LT13N LT13S Metal Shaded Flare Light with 11W wedge base bulb and Black finish Metal Three Tier Light with 7W wedge base bulb and Black finish Metal Three Tier Light with 7W wedge base bulb and Nickel finish Metal Three Tier Light with 7W wedge base bulb and Sand finish WEATHERPROOF • ENERGY CONTROLS • PROFESSIONAL LIGHTING • POOL & SPA • SURGE PROTECTION • CONSUMER Malibu Low Voltage Landscape Lighting ® LT406 LT406N Metal Two Tier Light with 4W wedge base bulb and Black finish Metal Two Tier Light with 4W wedge base bulb and Nickel finish WEATHERPROOF • ENERGY CONTROLS • PROFESSIONAL LIGHTING • POOL & SPA • SURGE PROTECTION • CONSUMER 137 Malibu Low Voltage Landscape Lighting ® Low Voltage Polymer Power Packs Intermatic offers the widest variety of Power Packs in any wattage and control option your system may require. Power Packs are available from 44 to 900 watts, allowing you to choose which power supply is right for your particular lighting plan. yyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyy yyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyy yyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyy yyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyy yyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyy yyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyy yyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyy yyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyy yyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyy yyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyy yyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyy yyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyy yyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyy yyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyy yyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyy yyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyy yyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyy yyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyy yyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyy yyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyy LD622L/ML60721 LV181/ML10781 Plastic Deck Light 4W wedge base bulb All Power Packs are certified for safe operation and long life. Keyhole mountings are featured for ease of operation and installation. See chart below for available Power Packs and features. Plastic Tier Light 7W wedge base bulb Models Max. Wattage Output Specifications LV103/ML91103 LV108/ML90708 ML44T ML60TW ML88T ML100T ML121RT ML200RT ML200RTW ML300RTW ML600TW ML900TW 44 Watt 60 Watt 88 Watt 100 Watt 121 Watt 200 Watt 200 Watt 300 Watt 600 Watt 900 Watt Timer with 2 sets of trippers Timer with 2 sets of trippers and ground shield Timer with 2 sets of trippers Timer with 2 sets of trippers Timer with 2 sets of trippers Timer with 2 sets of trippers Timer with 2 sets of trippers and ground shield Timer with 2 sets of trippers and ground shield Timer with 2 sets of trippers and ground shield Timer with 2 sets of trippers and ground shield Plastic Floodlight 11W wedge base bulb Plastic Floodlight 7W wedge base bulb IMPORTANT: When planning your lighting and choosing a Power Pack, your total bulb wattage must not exceed maximum transformer wattage output rating. Power PackModels LV183/ML11183 LD641/ML60704 Plastic Tier Light 11W wedge base bulb Plastic Deck Light 7W wedge base bulb yy yyyy yyyy yyyy yyyy yy yyyy yyyy yyyy yyyy yyyy yyyy yyyy yyyy yyyy yyyy yyyy yy yyyy yyyy yyyy yyyy yyyy yyyy yyyy yyyy yyyy yyyy yyyy yyyy yy yyyy yyyy yyyy yyyy yyyy yyyy yyyy yyyy yyyy yyyy yyyy yyyy yy yyyy yyyy yyyy yyyy yyyy yyyy yyyy yyyy yyyy yyyy yyyy yyyy yy yyyy yyyy yyyy yyyy yyyy yyyy yyyy yyyy yyyy yyyy yyyy yyyy yy yyyy yyyy yyyy yyyy yyyy yyyy yyyy yyyy yyyy yyyy yyyy yyyy yy yyyy yyyy yyyy yyyy yyyy yyyy yyyy yyyy yyyy yyyy yyyy yyyy yy yyyy yyyy yyyy yyyy yyyy yyyy yyyy yyyy yyyy yyyy yyyy yyyy yy yyyy yyyy yyyy yyyy yyyy yyyy yyyy yyyy yyyy yyyy yyyy yyyy yy yyyy yyyy yyyy yyyy yyyy yyyy yyyy yyyy yyyy yyyy yyyy yyyy yy yyyy yyyy yyyy yyyy yyyy yyyy yyyy yyyy yyyy yyyy yyyy yyyy yy yyyy yyyy yyyy yyyy yyyy yyyy yyyy yyyy yyyy yyyy yyyy yyyy yy yyyy yyyy yyyy yyyy yyyy yyyy yyyy yyyy yyyy yyyy yyyy yyyy yy yyyy yyyy yyyy yyyy yyyy yyyy yyyy yyyy yyyy yyyy yyyy yyyyyyyyyyyy yyyyyyyyyyyy yyyy yyyyyyyyyyyy LX9Z/ML90401 LX1/ML10401 Plastic Floodlight 4W wedge base bulb Plastic Tier Light 4W wedge base bulb yyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyy yyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyy yyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyy yyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyy yyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyy yy yy yy yy yy yy yy yy yy yy yy yy yy yy yy yy yy yy yy yy yy yy y yyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyy yyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyy yyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyy yyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyy yyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyy yyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyy yyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyy yy yy yy yy yy yy yy yy yy yy yy yy yy yy yy yy yy yy yy yy yy yy y yyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyy yyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyy yyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyy yyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyy yyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyy yyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyy ML44T ML60TW ML88T ML100T ML121RT ML200RT ML200RTW ML300RTW ML600TW ML900TW Low Voltage Cable For fast, easy installation of Malibu® light fixtures, use low voltage cable. It’s safe, weather-resistant, self sealing and available in 16, 14 and 12 gauge sizes. LD622/ML60722 Plastic Deck Light 4W wedge base bulb 138 WEATHERPROOF • ENERGY CONTROLS • PROFESSIONAL LIGHTING • POOL & SPA • SURGE PROTECTION • CONSUMER Malibu Solar-Powered Accent Lighting ® Solar accent lighting is the simplest and safest way to brighten your home’s walkways, decorate patios and flower beds or create an enchanting lake view. Solar powered light fixtures cost nothing to operate and each fixture automatically recharges during the day and turns on at dusk. Malibu solar accent lights utilize the latest in L.E.D. technology to create lights that are brighter and stay lit longer than other solar-powered brands. Choose from our new brighter white L.E.D. light fixtures or from our more traditional amber colored L.E.D. fixtures. Each fixture contains a scientifically designed solar collector panel that converts sunlight into electrical energy. With no plug-in receptacles or power packs, solar accent lights can be installed even in remote areas where the sun shines and regular power sources aren’t available. Malibu solar lights operate independently, allowing you to use as many as you like. Premium Metal Walk Light LZ7CT4 LZ7FC4 LZ7Z6 LZ51GR Metal Contemporary Walk Light with White L.E.D. Metal French Country Walk Light with White L.E.D. Premium Cast Metal Zen style Walk Light with White L.E.D. Metal French Lantern with White L.E.D., Graphite Finish LZ191 LZ305P LZ601 LZ602 Cast Metal Tier Light with White L.E.D. Metal Lantern with Graphite Finish and White L.E.D. Copper finish Metal Pillar-Style Walklight with White L.E.D. and Pewter finish. Metal Diamond Mission Light with Aged Brass Finish and White L.E.D. LZ603 LZ11101OB LZ11101P LZ11101RB Metal Pagoda Light with Black Finish and White L.E.D. Metal Walklight with White L.E.D. and Oil Bronze finish. Metal Walklight with White L.E.D. and Pewter finish. Metal Walklight with White L.E.D. and Rustic Brick finish. LZ191K WEATHERPROOF • ENERGY CONTROLS • PROFESSIONAL LIGHTING • POOL & SPA • SURGE PROTECTION • CONSUMER 139 Malibu Solar-Powered Accent Lighting ® Understanding Solar-Powered Accent Lighting Solar lights are not for every lighting application. Malibu Solar Lights produce a glow that is ideal for outlining locations and darkened areas such as steps, walks, etc. Solar Lights are perfect for for those applications where a regular power source is unavailable, where some sort of accent light is desired and where the area has exposure to the full daylight sun. Malibu Solar Lights can be installed just about anywhere; as long as there is enough sunlight available to recharge the batteries. The specially designed solar panel collects natural sunlight and converts it into electrical power that is stored in highly efficient, rechargeable batteries. Be sure all Solar collector panels are installed in a sunny location where they will receive adequate, unobstructed sunlight each day. Solar Light performance will be diminished during cloudy, rainy, or wintery weather conditions. With fully charged batteries, Solar Lights will provide many hours of nighttime illumination. LZ11101V LZ11771H LZ11771HK LZ14001H Metal Walklight with White L.E.D. and Verde finish. Metal Prairie Style Light with White L.E.D. and Architectural Bronze finish. Metal Prairie Style Light with White L.E.D. and Antique Copper finish. Metal Lantern Light with White L.E.D. and Black finish. LZ14001HP Pewter finish. LZ21811K LZ25030RB LZ230 Metal Fence Post Light with White L.E.D. and Antique Copper finish. Small Metal Prairie style Lantern with Amber L.E.D. and Rustic Brick finish. Metal Mission Light with White L.E.D. and Aged Brass finish. LZ25030V Verde finish. Metal Walk Lights LZ406 LZ407 LZ418 LZ422WBR Metal Tier Light with Amber L.E.D. Metal Tier Light with White L.E.D. and Pewter finish. Metal Walklight with Oil Rubbed Bronze Finish, White L.E.D.. Dark Brown Walklight with White L.E.D.. LZ422W Black Walklight with White L.E.D.. 140 WEATHERPROOF • ENERGY CONTROLS • PROFESSIONAL LIGHTING • POOL & SPA • SURGE PROTECTION • CONSUMER Malibu Solar-Powered Accent Lighting ® LZ10130 LZ10131 LZ10131P Metal Tier Light with Amber L.E.D.. Metal Tier Light with White L.E.D.. Metal Tier Light with White L.E.D. and Pewter finish. LZ1 LZ1W LZ3 LZ4H Plastic Tier Light with Amber L.E.D.. Plastic Tier Light with White L.E.D.. Plastic Contemporary Solar Fixture with Amber L.E.D. Plastic Hanging Carriage Light with Amber L.E.D. LZ3W LZ4HW White L.E.D. White L.E.D. Plastic Walk Lights LZ4HWGR White L.E.D. with Graphite finish. LZ4M LZ4MOB LZ6 LZ302 Plastic Carriage Light with White L.E.D. and Black finish. Plastic Carriage Light with White L.E.D. and Rubbed Bronze finish. Table Top Accent Light with Amber L.E.D. Plastic Post Top Light with White L.E.D. LZ4MK Antique Copper finish. WEATHERPROOF • ENERGY CONTROLS • PROFESSIONAL LIGHTING • POOL & SPA • SURGE PROTECTION • CONSUMER 141 Malibu Solar-Powered Accent Lighting ® LZ312 LZ701/LZ701W LZ702/LZ702W LZ703/LZ703W Path Marker Light with White L.E.D. Plastic Walklight with White or Amber L.E.D. and Brown finish. Plastic Walklight with White or Amber L.E.D. and Black finish. Plastic Walklight with White or Amber L.E.D. and Black finish. LZ704/LZ704W LZ705/LZ705W LZ20601P Plastic Walklight with White or Amber L.E.D. and Brown finish. Plastic Walklight with White or Amber L.E.D. and Black finish. Plastic Coach Light with White L.E.D. and Pewter finish. LZ413 LZ413RP4 LZ414 LZ415 Plastic Flood Light Set with Remote Panel and 3 White L.E.D.s per Lamp Plastic Flood Light Set with 4 Lamps, 3 White L.E.D.s per lamp Plastic Flood Light Set with Remote Panel and 3 White L.E.D.s per Lamp Flood Light with 3 White L.E.D.s Solar Flood Lights 142 WEATHERPROOF • ENERGY CONTROLS • PROFESSIONAL LIGHTING • POOL & SPA • SURGE PROTECTION • CONSUMER Malibu Solar-Powered Accent Lighting ® LZ419 LZ605RP Resin Flood Light with 3 White L.E.D.s Metal Flood Light with 12 White L.E.D.s, Black Finish Specialty Solar Lights LZ303RB LZ305FP LZ310 LZ314 Metal Hanging Lantern with White L.E.D. and Rustic Brick finish. Metal Pillar-Style Walklight with White Flickering L.E.D.s and Pewter finish. Cast Metal Lamp-Post Replacement Fixture with 1 Watt White L.E.D. Address Light with Amber L.E.D. LZ511A,B,C,R LZ604B LZ706 LZ16220 Driveway Markers with Steady ON or Flash Modes Solar Island Torch with Flickering Amber L.E.D.s Resin Pagoda Light with Amber L.E.D. and Natural finish. Plastic Deck Light with Amber L.E.D. WEATHERPROOF • ENERGY CONTROLS • PROFESSIONAL LIGHTING • POOL & SPA • SURGE PROTECTION • CONSUMER 143 Malibu Solar-Powered Accent Lighting ® LZ90004 LZ16551 LZB1 Replacement Batteries Plastic Floating Light with White L.E.D. Plastic Solar Luminary with Amber L.E.D Novelty Solar lights LZ1WU Replacement Bulb LZ306 LZ307 LZ308 LZ313 Decorative Frog Light with White L.E.D. Large Turtle with White L.E.D. Decorative Lighthouse with Amber L.E.D. Turtle with Amber L.E.D. Kits LZ15004 Nickel Metal Hydride replacements 144 LZ13RP4 LZ53RP4 LZ280RP4 Metal Tier Light Set with 2 White L.E.D.s per Lamp and Remote Panel, Black Finish Metal Deck Light Set with 2 White L.E.D.s per Lamp and Remote Panel, Oil Rubbed Bronze Finish Metal Tulip Set with 2 White L.E.D.s per Lamp and Remote Panel, Oil Rubbed Bronze Finish LZ635RP4 LZ501RP4 Metal Bollard Set with 2 White L.E.D.s per Lamp and Remote Panel, Black Finish Metal Walk Light Set with 2 White L.E.D.s per Lamp and Remote Panel, Oil Rubbed Bronze Finish WEATHERPROOF • ENERGY CONTROLS • PROFESSIONAL LIGHTING • POOL & SPA • SURGE PROTECTION • CONSUMER Malibu Outdoor Living ® Mosquito Sentinel 360 ACCESSORIES MZ951 Mosquito Sentinel 360 Octenol Lure MZ952 MZ501 Mosquito Sentinel 360 Replacement Nets Trap • Attracts and kills mosquitoes in your yard • Provides 360º protection against mosquitoes up to 1/2 acre • Uses safe low-voltage power - No propane cylinders to refill MZ953 Mosquito Sentinel 360 Replacement Bulbs MZ105 MZ904 MZ204G MZ301 • Repels Mosquitoes up to 400 Sq. Ft. • Patented chemical developed at University of Florida MZ101 MZ102 MZ902 • Blocks Mosquitoes up to 100 square feet! Patented Inhibitor blocks mosquito’s ability to track your scent. • Easy to Use • Long Lasting • Inhibitor refill lasts up to 3 weeks. WEATHERPROOF • ENERGY CONTROLS • PROFESSIONAL LIGHTING • POOL & SPA • SURGE PROTECTION • CONSUMER 145 Cross Reference Time Switch Motors Model (Series) to be used Description UPC* Item # Part # MOTOR ONLY OLD STYLE T100 T100, T170 24V 60Hz N/A T100R201, 125V 50Hz N/A T1400BR, 125V 60Hz WG430-10D T1800BR, 208/277V 50Hz WG434-20D§ T180, T500, 208/277V 60Hz WG433-20D WH10,30, 480V 60Hz WG436-20 WH40,70,80 MOTOR ONLY NEW STYLE T100 T100, T170 24V 60Hz CW1570-10D T180, 125V 60Hz WG1570-10D T100R201, 125V 50Hz WG1571-10D T100R301, 208/277V 50Hz WG1574-10D WH10,30, 208/277V 60Hz WG1573-10D WH40,70,80 480V 60Hz WG1576-10D MOTOR ONLY T100CR T100CR, 24V 60Hz N/A T170CR, 125V 50Hz WG1381-10§ T1400BCR, 125V 60Hz WG1380-11§ T1800BCR 208/277V 50Hz N/A 208/277V 60Hz WG1383-11§ 480V 60Hz N/A MOTOR AND CARRYOVER COMBINED T100CR T100CR, 24V 60Hz N/A T170CR, 125V 50Hz 131T93GA T1400BCR, 125V 60Hz 131T68GA T1800BCR 208/277V 50Hz 131T70GA 208/277V 60Hz 131T69GA 480V 60Hz N/A MOTOR ONLY AT1300R 24V 60Hz N/A 125V 50Hz N/A 125V 60Hz WG430-20D 208/277V 50Hz WG434-20§ 208/277V 60Hz WG433-20D 480V 60Hz WG436-20 Malibu Repl. 125V 60Hz WG630D Motors 125V 60Hz WG1750-10§ 125V 60Hz N/A MOTOR ONLY T1900, 24V 60Hz N/A T8800, 125V 50Hz N/A R8800 125V 60Hz WG730-14D 208/277V 50Hz N/A 208/277V 60Hz WG733-14D 480V 60Hz WG736-14D MOTOR ONLY T7400B 24V 60Hz N/A T7800B 125V 50Hz N/A 125V 60Hz WG1600-11 208/277V 50Hz N/A 208/277V 60Hz WG1603-11D 480V 60Hz WG1606-11§ 11972 6 11978* 11976 5 11979* 10828 8 11915 4 11919 2 11932 1 02012 2 11938 3 11903* 11902* 11904* 60090 21170 60091 21180 02009 2 11978* 02010 8 11979* 02013* 11911* 12001* 12005 1 12008 2 11939 0 11951 2 11948 2 Model (Series) to be used Description Part # MOTOR ONLY T7400BC 24V 60Hz N/A T7800BC 125V 50Hz WG1381-10§ 125V 60Hz WG1380-11 208/277V 50Hz N/A 208/277V 60Hz WG1383-11 480V 60Hz N/A MOTOR AND CARRYOVER COMBINED T7400BC 24V 60Hz N/A T7800BC 125V 50Hz 131T93GA 125V 60Hz 131T68GA§ 208/277V 50Hz N/A 208/277V 60Hz 131T69GA 480V 60Hz N/A MOTOR AND CARRYOVER COMBINED V41079CR 24V 60Hz N/A V45000 125V 50Hz 131T93GA V46100C 125V 60Hz 131T68GA§ 208/277V 50Hz N/A 208/277V 60Hz 131T69GA 480V 60Hz N/A MOTOR ONLY V45400 24V 60Hz N/A V46400 125V 50Hz WG1381-10§ 125V 60Hz WG1380-11§ 208/277V 50Hz N/A 208/277V 60Hz WG1383-11§ 480V 60Hz N/A MOTOR ONLY T2000 24V 60Hz CW720-10§ 125V 50Hz N/A 125V 60Hz WG720-10D 208/277V 50Hz WG724-10§ 208/277V 60Hz WG723-10D§ 480V 60Hz N/A MOTOR ONLY V47000 24V 60Hz N/A V48000 125V 50Hz N/A V49000 125V 60Hz WG690-10 208/277V 50Hz N/A 208/277V 60Hz N/A 480V 60Hz N/A MOTOR ONLY LS7000 24V 60Hz CW190-10D 125V 50Hz WG191-10§ 125V 60Hz WG190-15D 208/277V 50Hz WG194-10§ 208/277V 60Hz N/A 480V 60Hz N/A MOTOR ONLY E1000 24V 60Hz N/A 125V 50Hz N/A 125V 60Hz WG230-13D 208/277V 50Hz N/A 208/277V 60Hz WG233-18§ 480V 60Hz N/A UPC* Item # 11903* 11902 4 11905 5 60090 21170 21180 60090 21170 21180 11903* 11900* 11904* 10846* 11997 0 12000* 11999 4 11991* 10839 4 11957* 11956 7 11960* Model (Series) to be used Description MOTOR ONLY C8815 24V 60Hz 125V 50Hz 125V 60Hz 208/277V 50Hz 208/277V 60Hz 480V 60Hz MOTOR ONLY C8825 24V 60Hz 125V 50Hz 125V 60Hz 208/277V 50Hz 208/277V 60Hz 480V 60Hz MOTOR ONLY C8835 24V 60Hz 125V 50Hz 125V 60Hz 208/277V 50Hz 208/277V 60Hz 480V 60Hz MOTOR ONLY C8845 24V 60Hz 125V 50Hz 125V 60Hz 208/277V 50Hz 208/277V 60Hz 480V 60Hz MOTOR ONLY C8855 24V 60Hz 125V 50Hz 125V 60Hz 208/277V 50Hz 208/277V 60Hz 480V 60Hz MOTOR ONLY C8865 24V 60Hz 125V 50Hz 125V 60Hz 208/277V 50Hz 208/277V 60Hz 480V 60Hz MOTOR ONLY C8866 24V 60Hz 125V 50Hz 125V 60Hz 208/277V 50Hz 208/277V 60Hz 480V 60Hz Part # N/A N/A WG790-11D N/A N/A N/A N/A N/A WG760-10 N/A N/A N/A N/A N/A WG780-12D N/A N/A N/A N/A N/A WG750-10D N/A N/A N/A N/A N/A WG800-11D N/A N/A N/A CW770-10§ N/A WG770-10D N/A WG773-10 N/A CW770-10§ N/A WG770-10 WG774-10 WG773-10 N/A UPC* Item # 12019 8 12011* 12017 4 12010 5 10854 7 10852* 12013 6 12014* 10852* 12012* 12015* 12014* N/A Not available. All time switch motors are available in voltage and cycle shown in 2nd column. For example: To order new style T100 Series Motor in 60Hz 125V, order WG1570-10D. 11966 6 60037 NOTE: Carryover only sold as a complete unit with motor. **These voltages and corresponding motor numbers apply to all model numbers. § Available while supplies last. Internal revisions may result in the motor you receive having a different dash number (WG430-3 vs. WG430-10) than the motor ordered. This revision has no effect on the motor function. 146 WEATHERPROOF • ENERGY CONTROLS • PROFESSIONAL LIGHTING • POOL & SPA • SURGE PROTECTION • CONSUMER Cross Reference 24-Hour Time Switches INTERMATIC Paragon Specialty Time Switches Tork 24 Hour Time Switches (1 hour minimum “ON’’ time) T101 4001-00 1101/1191 T102 4002-71 1102 T103 4003-00 1103/1962 T104 4004-71, 4004-20 1104/1962 T105 4005-00S 3121 T101B 4001-00V — T101R 4011-00 1101-0/1191-0 T102R 4012-20 — T103R 4013-00 1103-0/1962-0 T104R 4014-71, 4014-20 1104-0 T106R — — 24 Hour Time Switches with Skip-A-Day (1 hour minimum “ON’’ time) T171 P101S 7100 T172 — 7102 T173 4003-00S, P103S 7200 T174 4004-71S, P104S 7202 T175 4005-00S 7120 T176 4006-71S 7122 T171R 4013-00S 7100-0 T172R 4014-20S 7102-0 T173R 4013-00S 7200-0 T174R 4014-20S, 4014-71S 7202-0 T176R — 7122-0 T1471BR 47017-0S 7300 T1472BR 47017-20S 7302 T1475BR — — T1871BR — 7220 24 Hour Time Switches with Skip-A-Day and Carryover 1 hour minimum ‘’ON’’ time T1471BCR 47217-00S 7300L/7300L-0 T171CR — — T173CR 4213-0S 7200L T174CR 4114-27S 7202L Water Heater Time Switches with manual “external override’’ WH40 — WH2 INTERMATIC Paragon Special Timing Cycle Tork Irrigation Time Switches (12 minute minimum “ON’’ time) T8805P101C — — R8806P101C — — Cycle Time Switches (5 minute-4 hour dial) C8815 — 8121 C8835 — 8301 C8845 — — C8855 — 8061 C8865 — 8601 C8866 — 8602 Lighting Control Centers (7 day dial) T51211BC — T920L T51311BC — T930L Swimming Pool Time Switches INTERMATIC Paragon 24 Hour Time Switches in Plastic Case T101P 4011-00P T102P — T103P 4013-00P T104P 4014-71P 24 Hour Time Switches w/ Heater Circuit T101R201 41011-00 T104R201 41014-20 T101P201 41011-00M T104P201 41014-20M 2 in 1 24 Hour Time Switches T10101R 4912-99 T10404R 4918-99 T12404R 4928-99 Tork 1101-N — 1103-N 1104-N — 1104FM — — 1101D 1104D 1104DF Astronomic Time Switches INTERMATIC Paragon Tork 24 Hour Time Switches 15 minute minimum “ON’’ time T1905 1015-00RS 8001 T1905R 42011-00 — T1906 1015-00RS 8004 T1975 1015-00RS 8007 T1976 1015-00RS 8008 T1975E 1015-40TS 8001-U Signal Timers ET279C 25001-0S — ET279C 25002-0S — ET279C 23001-00S 5701/5702 ET279C 23002-20S — ET279C 23002-00S — 24 Hour Switching (with adjustable 10-60 min.) “ON’’ times T185 8025-00 4277 Momentary Contact Time Switches (with dry contacts for low voltage remote and mechanically held contactor control) ET279C 47016-00S 1847A ET279C 47216-00S 1847AL ET279C — 1847AW ET279C 7216-00 1847AWL 7-Day Time Switches INTERMATIC Paragon Tork T7401B T7402B T7801B T7802B T7401BC T7402BC T7801BC 7007-00 7007-20, 7007-71 7008-00 7008-20, 7008-71 7217-00 7217-20 7218-00 W100/W200/ W300/W400 W202/W302/W402 W120/W220 W222 W300L/W400L W302L/W402L W220L INTERMATIC Paragon Tork Astro Dial V45471R V45472R V45471CR V45472CR In-Wall Timers 4003SZ,47017-00S & 00SZ 47017-71S & 71SZ 47217-00SZ 47217-20SZ & 27SZ 7200Z/7300Z 7202Z/7302Z 7200ZL/7300ZL 7202ZL/7302ZL INTERMATIC Grasslin Paragon Tork 24-Hour Electro-Mechanical In-Wall Timers E1010 — — E1020/E1120 KM2 ST-16 701A/701AC E1221 — 701A-2G E1220 KM2 ST-2G — 24 Hour Electronic In-Wall Timers EJ351C ETC-502 — EJ353C ETC-503 — EI500C — — — WB101 WB103 WB103 — — — Digital In-Wall Timers INTERMATIC Paragon Interval Timers – Electronic EI15MH E500/ET2000/ET1100 EI200 — EI210 — EI220 — EI230 — Tork — — — — — WEATHERPROOF • ENERGY CONTROLS • PROFESSIONAL LIGHTING • POOL & SPA • SURGE PROTECTION • CONSUMER 147 Cross Reference Spring Wound Timers INTERMATIC† M.H. Rhodes Mark Time Tork†† Paragon††† FF5M/FD5M FF15M/FD15M FF30M/FD30M FF60M/FD60M FF2H/FD2H FF4H/FD4H FF6H/FD6H FF12H/FD12H FF5MH FF15MH/FD15MH FF30MH/FD30MH FF60MH/FD60MH FF6HH/FD6HH FF12HH/FD12HH 90004/9305M 90005/9315M 90006/9330M 90008/9360M 90281/9302H 90240/9304H 90007/9306H 90001/9312H 90030 90539/9315MH 90032/9330MH 90024/9360MH 90017/9306HH 90015/9312HH A505M A515M A530M A560M A502H A504H A506H A512H ––– A515MH A530MH A560MH A506HH A512HH SW5M/SWD5M SW15M/SWD15M SW30M/SWD30M SW60M/SWD60M SW2H/SWD2H SW4H/SWD4H SW6H/SWD6H SW12H/SWD12H SW5MH SW15MH/SWD15MH SW30MH/SWD30MH SW60MH/SWD60MH SW6HH/SWD6HH SW12HH/SWD12HH INTERMATIC† M.H. Rhodes *SPDT (for reverse action applications) FF32HH 9302HH FF34HH 9304HH FF36H/FD36H ––– FF312H ––– FF315M 90012 FF330M 90011 FF360M 90010 DPST (for breaking both sides of 240 volt loads) FF415M/FD415M ––– FF430M/FD430M ––– FF460M/FD460M ––– FF46H/FD46H ––– FF412H ––– Tork†† Paragon††† ––– ––– ––– ––– ––– ––– ––– ––– ––– ––– ––– ––– ––– ––– ––– ––– ––– ––– ––– ––– ––– ––– ––– ––– † FF Models with brushed aluminum plate for commercial/industrial applications. FD Models-decorator design with ivory or white time dial for use with existing toggle or decorator style switch plate. †† Decorator models only. ††† PSW series no longer available; replaced by SW and SWD series Next Generation 365 Day Multi-Function Electronic Time Switches INTERMATIC Paragon Tork Lithonia ET70115C (SPDT) *(SPST) **(DPDT) EL71/Series EC7001/208-240V EC7001/277V EC7001/208-277V EC7004/208-240V* EC7004/277V* EC7004/208-277V* EC71/18S/120V EC71D/18S/240V EC71ST/120V EC71ST/240V EC71ST/277V EC71STM/120V EC71STM/277V EC365/C/120V EL71PC/Series EC71STN3/120V DT100** DT100-2** DT100-3** DZS100** –– ET70115CR (SPDT) **(DPDT) ET70115CR24 for 24 Volt / 60 Hz Input only 148 INTERMATIC ET70215C ET70215CR Paragon EL72/Series EC72/120V EC72/240V EC72/277V EC72D/120V EC72D/240V EC72ST/120V EC72ST/240V EC72ST/277V EL72PC/Series EC72STN3/120V ET70215CR24 for 24 Volt / 60 Hz Input only DZS100A DTS100A DG180 DG180-2 DG180-3 DG100 DG100-2 DG100-3 DG120** DG120-2** DZS100** DZS100-2** DZS100-3** DGS100 DGS100-2 DGS100-3 DGS180 DGS180-2 DGS180-3 DGM100** DGM100-2** DGM100-3** DWZ100A** — ET70415CR ET70415CR24 for 24 Volt / 60 Hz Input only ET70815CR — ET70815CR24 for 24 Volt / 60 Hz Input only IMPORTANT NOTE: Review manufacturer’s literature for possible feature differences ET71615CR ET71615CR24 for 24 Volt / 60 Hz Input only EL74 EC74/50S/120V EC74/50S/240V EC74/120D/120/240V EC74/192MA/120/240V EL78 EC77/140/120, 240V EL712 EC712/120, 240V EC128 Tork DT200 DT200-2 DT200-3 Lithonia –– DZS200A DTS200A DZM200A DS200 DS200-2 DS200-3 DZS200 DZS200-2 DZS200-3 DZM200 DZM200-2 DZM200-3 DZS400A DTS400A Z400B Z400B-2 K400Z K400Z-2 K401Z K401Z-2 DIN103A (3PDT) K600Z K800Z K600Z-2 K800Z-2 K601Z K601Z-2 K801Z K801Z-2 AI200 A1600 –– –– LITEKEEPER LK8 LK16 CK16 LK32† CK32† WEATHERPROOF • ENERGY CONTROLS • PROFESSIONAL LIGHTING • POOL & SPA • SURGE PROTECTION • CONSUMER Cross Reference Weatherproof Outdoor Receptacle Covers Intermatic WP1000C WP1000GC WP1000HC WP1000HGC WP1000RC WP1000HRC WP1010C WP1010HC WP1010HMC WP1010MC WP1020C WP1030C WP1030MC WP1050 WP1100C WP1110C WP1150C WP1100WC WP1110WC WP1220C WP1230C WP1250C WP2000 Taymac Carlon Cooper Arlington T&B Raco P&S n/a n/a n/a n/a 71101* n/a n/a n/a MX3300 MX3200 MM2440C n/a MX6200* MM7440C MM400C n/a MM740C n/a n/a MM2440C* n/a MM7440C* n/a E9UVCRN E9UVGRN E9UHCRN E9UVGRN n/a n/a E9UDVCRN n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a E9U2CRN* n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a WIU-1 n/a WIU-1D WIU-1W n/a WIU-2* n/a n/a n/a n/a n/a n/a n/a DBV* series DBV* series n/a n/a n/a n/a DBUL1DC n/a n/a n/a DBU1C n/a n/a DBUL1 n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a CKMD* CKSDV* n/a n/a 2CKD* n/a CKNM* n/a n/a n/a n/a 2CKNM* n/a n/a n/a 5752-0* n/a 5761-0* n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a 5770-0* n/a 5789-0 n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a WIUC10CL n/a WIUC10DL WIUC10WL n/a n/a WIUC20CL n/a n/a *Competitive product does not meet all possible device configurations and installation methods that the Intermatic cover handles. 7-Day Electronic Time Switches 24 Hour Electronic Time Switches INTERMATIC Paragon Tork EZ Controls INTERMATIC Paragon Tork EZ Controls ET171C (SPST) *(SPDT) EC7000/120* ES101, EW101 ES120*, EW120* DG100*, DG180* DIN101A* ES103, EW103 EZ-701-1 ET100C (SPST) *(SPDT) EC1015P/120* EC4000/120* EC4004/120 EC4004P/120 EC4004PC/120 EC4000P/120* EC4000PC/120* EC11 & 11D/120* — E101, E120* EZ-T101 E101, E120* EZ-T101 E101-2 EZ-T102 EC7004/120 ET173C (DPST) EC7005/120 ET174C (DPST) *(SPDT) EC7000/208-240* ET279C (SPST) *(SPDT) **(DPDT) EC7000/277* EC7004/208-240 EC7004/277 EC7005/120, 208-240 EC7005/277 EC11 Series* EC7001/120* ET8115C EC71/30S/120 ES103-2,ES103-3 ES120-2*, ES120-3* EW103-2, EW103-3 DGM100** CD100A, DS200** DIN100*, DIN200* E, ES & EW120 DG100, DG180 EZ-701-1A EZ-701-2 EZ-701-2A EZ-701-72 ET101C (SPST) *(SPDT) ET102C (SPST) *(SPDT) EZ-701-2M** EZ-T105 EZ-701-1A (SPST) ET8215C ET8215C *(SPDT) **(DPDT) EH10†† EH40†† — EC71D/30SM/ 120* — — †† With external load indicator and external load override. DIN101A DG120 (DPDT) DGM100 — EZ-701-2M EH10 EH20 — — **(DPST) ET103C (DPST) ET104C (DPST) EC1015P/208-277 EC4000/208-277* EC4004/208-277 EC4004P/208-277 EC4000P/208-277 EC4004PC/208-277 EC4005P/120, 208-240** EC4005PC/120, 208-240** EC11D/240* — EC4005/120-240 E101-3 E120-2* E120-3* E103 E103-2, E103-3 EZ-T103 EZ-T104 Astronomic Electronic Time Switches INTERMATIC Paragon Tork EZ Controls ET70115CR† (SPDT) EC71ST/120 EC71ST-N3/120V EC71ST/277 DZS100 EZ-701-2AS DZS100-3 EZ-701-72AS † Replaces ET816CR and ET833CR. NOTE: ET70000 Series provides astronomic programming for any circuit(s). WEATHERPROOF • ENERGY CONTROLS • PROFESSIONAL LIGHTING • POOL & SPA • SURGE PROTECTION • CONSUMER 149 Cross Reference High Intensity Discharge (HID) Lighting Intermatic RAB Stonco Intermatic RAB Stonco WL050MH WL070MH WL100MH WL150MH WL175MH WL250MH WL400MH WL035HPS WL050HPS WL070HPS WL100HPS WL150HPS WL250HPS WL400HPS FL050MH FL070MH FL100MH FL150MH WP1H50 WP1H70 WP1H100 WP2H150QT WP2H175QT WP3H250QT WP4H400QT WP1SN35 WP1SN50 WP1SN70 WP1SN100 WP2SH150QT WP3SC250QT WP4SC400QT FFH50 FFH70 EZHH100QT EZHH150QT LPSC50MA-8 LPSC70MA-8 LPM2C100MA-8 WPM150MA-8 WPM175MA-8 WP250MA-8 WP400MA-8 WNPS35NLXL WNPS50NLXL WNPS70NLXL-8 WNPS100NLXL-8 WPM150NLXL-8 WP250NLXL-8 WP400LXL-8 TLX50NMAL-1 SLA70NMAL-1 SLA100MAL-8 SLA150MAL-8 FL175MH FL250MH FL400MH FL035HPS FL050HPS FL070HPS FL100HPS FL150HPS FL250HPS FL400HPS DD175MV DD150HPS FL150Q FL300Q FL500Q WL070HPSPC CP150HPS EZHH175QT FZH250QT FZH400QT FF35 FF50 FF70 EZSH100 EZSH150QT FZS250QT FZS400QT YLM175 YLS150 QF150 QF300 QF500 WPTS70 VAN5S150QT SLA175MAL-8 SLM250MAL-8 SLM400MAL-8 TLX35NLXL-1 TLX50NLXL-1 TLX70NLXL-1 SLA100LXL-8 SLA150LXL-8 SLM250LXL-8 SLM400LXL-8 DTDA175NMML-1 DTDA150NLXL-1 EQX150L EQ300L EQ500L TLW70NLXL-1 LCQ155LXL-8 Electronic Astronomic Time Switches Intermatic Paragon SPST Astro Time Switches in NEMA 1 Case ET8015C — SPST Astro Time Switches in NEMA 3R Case ET8015CR EC365DST1/120V SPDT Astro Time Switches in NEMA 1 Case ET8115C — SPDT Astro Time Switches in NEMA 3R Case ET8115CR EL71/120V EL71/208-240V EL71/277V DPST Astro Time Switches in NEMA 1 Case ET8215C — DPST Astro Time Switches in NEMA 3R Case ET8215CR EC365DST2/120V EC365DST2/277V EL72/120V EL72/208-240V EL72/277V 150 Electronic Auto-Off Timers Tork — — — DWZ100A DZS100A — DW200A DZS200A Intermatic 5-10-15-30 Minute Range EI200 EI200LA EI200W 10-20-30-60 Minute Range EI210 EI210LA EI210W 1-2-4-8 Hour Range EI220 EI220LA EI220W 2-4-8-12 Hour Range EI230 EI230LA EI230W Leviton Leviton 6230MI 6230MA 6230MW — — — 6260MI 6260MA 6260MW 6560MI 6560MA 6560MW — — — — — — 6212HI 6212HA 6212HW 6512HI 6512HA 6512HW WEATHERPROOF • ENERGY CONTROLS • PROFESSIONAL LIGHTING • POOL & SPA • SURGE PROTECTION • CONSUMER Cross Reference Photo Controls Intermatic ALR Tork Ripley Mulberry Precision Paragon Fisher Pierce K4021C K4024 K4022 K4033 K4023C K4035 K4321C K4121C K4124 K4122 K4123C K4133 K4135 K4141C K4221C K4224 K4222 K4233 K4235 K4236 K4121M K4123M K4136M K4251 K4253 LC4521C/K4521 LC4521LA LC4523 LC4523LA LC4535 LC4535LA LC4536C LC4536LA K4524 K4522 K4533 K4535 K4023* K1121 K1122 LC2000 LC2000 Accessories K4500 K121 K122 AA105 AA106 AA107 AA108 AA1068 — AA105W PT15 AT16 AT17 PT168/AT368 AT18 AT19/PT19/AT39 AT30 (metal) SAT15/SPT15 SAT16 SAT17 SAT18 SAT19/SPT19 PT20/SAT168/SPT168 AT15 AT168 AT20 TL115 TL168 LC120 BF120/M120 LC208-277 BF208-277/M208-277 — BF480/M480 — BFPV/MPV — — — — AA1068W/AA1068P — — — — 3000 — — — 3002 — 3010 2101/2100 — — — — — 2105 (polycarbonate) 2001/3020 — — — — 2104/2102/2002 2101 2104 2107 2021 2022 2003/5001S 2003S/5021S 2004/5004S 2004S/5024S — 2008D/5008S/2008** — 2007D/5007S/2007** — — — 2008 — — — 2005 2007 7001/7011 — — — 7002/7003/7012/7013 — 7105 — — — — — — — — — — — — — — — — — — — 7046 — 7049 — — 6190** — — — — — — — — 6146/6281 — 30850 30851 30852 — 30853 — 30855 30825/30820 30827 30829 — 30831 — 30847 30826/30868 — — — — 30830/30833/3082 — — — — — 30834 — 30837 — 30842 — 30844 — 30836 30838 30840 30842 — — — — — A105 — — — A1068 — A105W T-15 — — T-168 — T-19 T-30 ST-15 — — — ST-19 ST-168 TL15AL — — ET-15 ET-168 P-2275/M2275 P2275LA P68275 8672** P7275 LM7275/8694** P26275/8690N** 8690** — — — P7275 A1068W/A1068P — — EC120 EC240,ECDV LB201-00 — — — LB201-71 — LB201W-00 CW201-00 — — CW201-71 — — CW302-00 CW201S-00 — — — — CW201-71 CW201-00 CW201-71 CW201-70 PN201-00 — TL201-00 — TL201-71 — — — TL201-70 — — — — — — — — — — FA105/FA305/6241A/6210 — 6242A — FA1068 — FA105W 6241B/FT15 — 6242B FT168 — FT19 — SFT15 — — — SFT19 SFT168 FT15 FT168 — FL115 — NFP120/N6401-NS NFP120H/N7760-SSS** NFP277 NFP-277H/M208-277 — SC10 AM1ANB AM1A, AM2A, AM2ANB 2500/5500 2223/2224 2421/2422 6005/6007 — 5925/5926/5927 30846 — 30862 JP275 603 M2A SC201-99 — TB201-99 NS1038-1 NS47681 NS476-71/NS476-732 7790B-NSS** 7790B-ESS**/N7790B — — — — — — — 7760/7762/7790B/7792B 7770/7772/7790B * With K4001 ** Quick response type For quick access to Intermatic Energy Control products and Weatherproof Covers simply go to www.intermatic.com/energycontrols This will take you directly to our Energy Controls Search where you may search for products by Application, by Feature, by Series or by Category. This file provides you the ability to download and print specifications, wiring diagrams and product photographs. Many of our instruction sheets, all in pdf format, can also be found on the site. WEATHERPROOF • ENERGY CONTROLS • PROFESSIONAL LIGHTING • POOL & SPA • SURGE PROTECTION • CONSUMER 151 INDUSTRIAL & COMMERCIAL SALES REPRESENTATIVES CORPORATE HEADQUARTERS: General Catalog 7777 Winn Road Spring Grove, IL 60081 Phone: (815) 675-2321 Fax: (815) 675-7105 WEATHERPROOF www.intermatic.com 2. P&M SALES, LTD. 400 Chapel Road, Unit 2-1, South Windsor, CT 06074-4169 Phone: (860) 528-9181 FAX: (860) 528-7050 3. * BURGOYNE SALES, INC. 110 McGaw Drive, Raritan Industrial Center, Edison, NJ 08837 Phone: (732) 225-0450 FAX: 732-225-7454 Effective January 2007 MILLS TALBOT CO. 100 Thompson Street, Fayetteville, NY 13066 Phone: (315) 637-0511 FAX: (315) 637-0512 22. ELECTRA SALES 2320 Hinton Drive, Irving, TX 75061 Phone: (972) 554-8200 FAX: (972)554-7861 39. BAILEY/MARTIN & ASSOCIATES 935 6th Ave. South, Nashville, TN 37203 Phone: (615) 256-3000 FAX: (615) 242-6780 5. * R.C. COLERICK, INC. 1244 Ritchie Hwy., Suite 13, Arnold, MD 21012 Phone: (410) 421-9511 FAX: (410) 421-9514 23. ELECTRA SALES 2200 SW 14th St., Oklahoma City, OK 73108 Phone: (405) 722-6905 FAX (405) 722-2458 40. CURTIS H. STOUT INC. 310 Edgewood Terrace, Suite B, Jackson, MS 39206 Phone: (601) 366-1903 FAX: (601) 981-8439 6. * SYNERGY ELECTRICAL SALES 95 Canal Rd., Penn Warner Industrial Park, Fairless Hills, PA 19030 Phone: (800) 220-5691 FAX: (215) 428-1137 24. CURTIS H. STOUT INC. 2400 Cantrell Road, Suite 100, Little Rock, AR 72202 Phone: (501) 372-2555 FAX: (501) 375-4451 41. 25. CURTIS H. STOUT INC. 3478 Winhoma Drive, Memphis, TN 38118 Phone: (901) 362-1616 FAX: 901-795-0481 INTERMATIC INCORPORATED CANADA 6430-B Kennedy Rd. Unit B Mississauga, Ontario L5T 2Z5 Canada Phone: (905) 696-7621 FAX: (905) 6960846 4. 7. Electra Products, Inc. 2750 Breckinridge Blvd Suite 400 Duluth, GA 30095 Phone: (770) 451-9146 Phone: (800) 225-4820 FAX: (770) 451-9424 8. * PAOLICELLI & ASSOCIATES Gregg & Hammond Sts., Carnegie Industrial Park, P.O. Box 665, Carnegie, PA 15106-0665 Phone: (412) 276-8816 FAX: (412) 276-6670 9. * E.F. LOMBARDI CO. P.O. Box 669186, Charlotte, NC 28266, 2101 Freedom Drive, Charlotte, NC 28208 Phone: (704) 334-1637 FAX: (704) 372-6078 10. * INTERMATIC INCORPORATED 3150 NW Prospect Road, Suite 330, Ft. Lauderdale, FL 33309 Phone: (954) 535-0020 FAX: (954) 535-0040 11. 26. CURTIS H. STOUT INC. 201 Evans Road, #110, Harahan, LA 70123 Phone: (504) 818-1848 FAX: (504) 818-1631 42. INTRALEC ELECTRICAL PRODUCTS LTD. 1200 Cardiff Blvd, Unit 1, Mississauga, Ontario Canada L5S 1P6 Phone: (905) 670-0970 FAX: (905) 670-3098 27. STOVER & ASSOCIATES, INC. 4460 W. 107th St., Shawnee Mission, KS 66207 Phone: (913) 649-6600 FAX: (913) 649-2762 43. 28. JOE BERTSCH ELECTRICAL SALES 5832 Dry Creek Lane N.E., Cedar Rapids, IA 52402, Phone: (319) 395-9220 FAX: (319) 395-9224 ADANAC #3-2075 Brigantine Drive, Coquitlam, British Columbia, Canada V3K 7B8 Phone: (604) 540-0220 FAX: (604) 540-0124 44. 29. JOE BERTSCH ELECTRICAL SALES 201 S. 84th St, Suite D, Lincoln, NE 68510 Phone: (402) 488-1614 FAX: (402) 488-1615 D.A.D. SALES 2013, 17th Ave., Didsbury, Alberta TOM OWO, Canada T2G 5G5 Phone: (403) 335-3531 FAX: (403) 335-8347 45. JEBCO AGENCIES, LTD. #4 - 2225 First Avenue North, Saskatoon, Saskatchewan, Canada S7K 2A5 Phone: (306) 373-0771 FAX: (306) 374-8023 30. 12. * RIFFLE & ASSOCIATES INC. 2671 Crescentville Rd., Cincinnati, OH 45241 Phone: (513) 771-0002 FAX: (513) 771-0011 JOE BERTSCH ELECTRICAL SALES 8450 Hickman Rd., Suite 15F, Des Moines, IA 50325 Phone: (515) 276-8967 FAX: (515) 276-8968 46. 31. LEE-NOONAN CO. 2230 Country Rd. H2, Moundsview, MN 55112 Phone: (763) 278-1036 FAX: (763) 560-3282 JEBCO AGENCIES, LTD. Unit 19 – 1865 Sargent Avenue, Winnipeg, Manitoba Canada R3H 0E4 Phone: (204) 786-2604 FAX: (204) 786-4734 47. 32. CENTAURI SALES 10708 Elena Dr. NE, Albuquerque, NM 87122 Phone: (505) 823-9816 FAX: (505) 823-9608 CONTACT DELAGE, INC. 135 J.A. Bombardier, Suite 90, Boucherville, Quebec Canada J4B 8P1 Phone: (450) 449-9444 FAX: (450) 449-6090 48. BROCKWAY ENTERPRISES 51 Cobequid Road, Suite 203 Lower Sackville, Nova Scotia, Canada B4C 2N1 Phone: (902) 865-4192 FAX: (902) 865-5967 49. BROCKWAY ENTERPRISES 7 Howard Court, Quispamsis, New Brunswick, Canada E2E 4J6 Phone: (506) 849-6000 FAX: (506) 847-5329 50. BROCKWAY ENTERPRISES 62 Kerry Avenue, Conception Bay South, New Foundland, Canada A1X 7H7 Phone: (709) 834-7444 FAX: (709) 834-7446 51. BOB JONES & ASSOCIATES 3837 E. Anne Street, Phoenix, Arizona 85040 Phone: (602)-437-1111 FAX: (602)-437-2339 14. 15. 16. 17. 18. 19. 20. RIFFLE & ASSOCIATES 16760 W. Park Circle Dr., Chagrin Falls, OH 44023 Phone: (440) 543-8257 FAX: (440) 543-7236 ELECTROCOM-MIDWEST SALES, INC. (EAST) 32500 Concord Drive, Suite 298, Madison Heights, MI 48071 Phone: (248) 307-1640 FAX: (248) 307-1630 ELECTROCOM-MIDWEST SALES, INC. (WEST) 4485 Plainfield N.E. Suite 103, Grand Rapids, MI 49525 Phone: (616) 364-8084 FAX: (616) 364-0135 ARTHUR A. BOYLE CO., INC. 5172 E. 65th Street, Indianapolis, IN 46220 Phone: (800) 776-9101 (317) 577-9100 FAX: (317) 577-9161 LAKESHORE ELECTRICAL, INC. 614 W. Brown Deer Rd., Suite 230, Bayside, WI 53217 Phone: (414) 228-0580 (800) 229-2227 FAX: (414) 228-0585 INTERMATIC INCORPORATED CORPORATE OFFICES Intermatic Plaza, Spring Grove, IL 60081-9698 Phone: (815) 675-2321 FAX: (815) 675-7105 MARTIN ELECTRICAL SALES, INC. 136 West Adams, P.O. Box 220189, Kirkwood, MO 63122 Phone: (314) 966-8659 FAX: (314) 966-6748 33. * BLOMQUIST, DENSELY & YOUNG (BDY) 2550 Decker Blvd. – #28, Salt Lake City, UT 84119 Phone: (801) 972-0070 FAX: (801) 973-0526 34. * PRO-LINES SALES & MARKETING P.O. Box 58248, Tukwila, WA 98138, 18700 – 80th Place South, Kent, WA 98032 Phone: (425) 272-0348 FAX: (425) 272-0362 35. PRO-LINES SALES & MARKETING SOUTH 7272 SW Durham Road, Suite 750, Portland, OR 97224 Phone: (503) 692-6993 FAX: (503) 612-6706 36. * INTERMATIC INCORPORATED 10524 Pioneer Blvd., Santa Fe Springs, CA 90670 Phone: (562) 906-0900 FAX: (562) 906-0955 ENERGY CONTROLS PROFESSIONAL LIGHTING INTERMATIC CANADIAN WAREHOUSE 1200 Cardiff Blvd, Mississauga, Ontario L5S 1P6 FAX: 1(800) 700-9671 Interwest 345 West 62nd Ave. Suite B Denver, CO. 80216 Phone: (303) 650-5162 FAX: (303) 650-5165 13. * L.P. CHICK CO. P.O. Box 19021, Louisville, KY 40259-0021; 1110 Industrial Blvd., Louisville, KY 40219 Phone: (502) 964-8181 FAX: (502) 964-8196 General Catalog 1. * DAVID ROLE & COMPANY 216 New Boston Street, Woburn, MA 01801 Phone: (781) 932-8810 FAX: (781) 932-8815 POOL & SPA CONTROLS SURGE PROTECTION 37. * LAU COMPANY 47-096 Kam Hwy, Kaneone Oahu, HI 96744 Phone: (808) 234-0199 FAX: (808) 235-7765 38. CONSUMER PRODUCTS CURTIS H. STOUT INC. 11051 Coursey Blvd., Suite B, Baton Rouge, LA 70816 Phone: (225) 291-5709 FAX: (225) 291-5713 www.intermatic.com * indicates carries stock of industrial and consumer products PRINTED IN U.S.A. ©COPYRIGHT 2007 INTERMATIC INC. TS89 300TS10057 Eff. 1/07 21. * ETEL 7106 Cavalcade, Houston, TX 77028 Phone: (713) 678-4460 FAX: (713) 678-4371
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.6 Linearized : No Page Mode : UseOutlines XMP Toolkit : 3.1-701 About : uuid:c57ba76c-9f2e-11da-b3fd-000a95a89824 Producer : QuarkXPress(tm) 6.5 Modify Date : 2007:03:26 15:00:36-05:00 Create Date : 2006:01:24 14:45:10-06:00 Metadata Date : 2007:03:26 15:00:36-05:00 Creator Tool : QuarkXPress(tm) 6.5 Document ID : uuid:49cd432e-8d1a-11da-9487-000a95a89824 Instance ID : uuid:a979d58a-dbd4-11db-85d3-000a95a89824 Format : application/pdf Creator : Paul Dulberg Title : Intermatic General Catalog Has XFA : No Page Count : 152 Page Layout : SinglePage Author : Paul DulbergEXIF Metadata provided by EXIF.tools