Product Detail Manual
291904-Catalog 291904-Catalog 291904-Catalog 662057 Batch5 unilog cesco-content
2014-07-05
: Pdf 21795-Attachment 1 21795-Attachment_1 662057 Batch5 unilog
Open the PDF directly: View PDF .
Page Count: 228
Download | |
Open PDF In Browser | View PDF |
Linear recessed and surface lighting Linear recessed and surface lighting B Philips Lightolier For complete specification information visit www.lightolier.com Linear recessed and surface lighting Section 4 Comprehensive lighting catalog 7th Edition C Linear recessed and surface lighting D Philips Lightolier For complete specification information visit www.lightolier.com Linear recessed and surface lighting Innovative specification grade fixtures utilizing today’s most energy efficient light sources. Philips Lightolier has a rich heritage of providing innovative, high quality recessed and surface lighting solutions for commercial, industrial and institutional markets. The line encompasses a diverse range of products, each designed to answer a specific lighting need. From the most comprehensive recessed soft lighting coffer styled direct/ indirect luminaires in the industry to innovative medical patient room lighting and parabolics designed for illuminating computer screens properly, Philips Lightolier features only energy-efficient products that provide effective, glare-free illumination to achieve the highest quality visual environment possible. Philips Lightolier works constantly to develop innovative new products and ensure that each new luminaire meets the most demanding specifications. Carefully designed around the light source, Philips Lightolier recessed and surface products ensure you the best luminaire for the task at hand. Highlighted here are just some of the products that showcase our design abilities. Contents Recessed soft lighting > 4.2 Recessed & wall washing > 4.90 Medical luminaires > 4.135 Architectural & surface utility > 4.146 Task lighting > 4.167 Special purpose & industrial > 4.172 General utility > 4.202 Comprehensive lighting catalog 7th Edition 4.1 Linear recessed and surface lighting Recessed soft lighting Gain a broader perspective with Soft Lights. Soft Lights encompasses a full range of luminaires, including decorative round, low-glare, recessed, non-directional recessed, solutions for shallow plenums, and more. Every Soft Lights luminaire enhances the quality of the visual environment by embracing the principles of quality visual concepts. 4.2 Philips Lightolier For complete specification information visit www.lightolier.com Linear recessed and surface lighting Contents LED recessed luminaires > 4.4 Alter family > 4.38 HP90 family > 4.8 Alter concept > 4.64 Paraplus II > 4.20 Coffaire family > 4.74 Opalescent family > 4.24 DL Day lighting system > 4.88 Skyway family > 4.30 Aletta > 4.36 Comprehensive lighting catalog 7th Edition 4.3 Linear recessed and surface lighting – Professional Recessed 2' x 2' LED luminaires Providing illumination virtually indistinguishable from traditional technologies while consuming less energy. The Philips Lightolier LED recessed luminaire , designed specifically around the led light source, sets a new standard for lighting efficiency, performance and sustainability. With our versatile offering of both contemporary and classical shielding appearances, lighting designers and architects have the ability to utilize a LED light source in any environment. Our LED product families, provide an ideal energy saving fixture for all 2' x 2’ recessed T-bar grid and drywall applications. Construction Electrical system • Integrated thermal management system conducts heat away from LEDs and transfers it to the surrounding environment. Designed to keep LEDs below specified maximum temperatures in typical commercial installations. • Nominal power factor = 0.9. • Field replaceable LED array accessible from below. • Integral, high efficiency driver and power supply. • Input voltage = 120V-277V, 50/60Hz • Depth = 5" LED Facts LEDs have no breakable glass, their solid-state design renders them impervious to shock, vibration, frequent switching and environmental extremes. With an average lifespan of more than 50,000 hours, these maintenance-free LED luminaires eliminate repeated relamping, and operate in ambient room temperatures of -22°F to +104°F [-30°C to +40°C]. • LEDs contain no toxic materials, hazardous mercury, or halogen gases. • LEDs emit no ultraviolet (UV) rays or infrared (IR) radiation. • LEDs do not require a material safety data sheet (MSDS) or hazardous waste disposal. • LEDs do not produce electro-magnetic interference. 4.4 Philips Lightolier For complete specification information visit www.lightolier.com Professional – Linear recessed and surface lighting Opalescent LED 2' x 2' Direct recessed air handling or static luminaires Opalescent 2x2 LED’s deep curved lens combined with a regressed frame opening that appears as a cove or skylight. The opal lens subtly highlights the ceiling plenum while shielding the LED’s from direct view. Opalescent blends with any architectural environment and creates balanced brightness, illuminating both vertical and horizontal surfaces. Features OPS22GPW38A40ULAG Candlepower Curve Reference data 5" (127mm) Delivered lumens Efficiency lm/w 3619 80.6 • High light transmission frost white acrylic lens. LED Driver 550 60˚ • Field replaceable LED array and drivers accessible from below. 1100 1650 Ordering information Type Size Static 2' x 2' Delivered lumens 2553 3167 3619 4140 Input watts 30.4 38.4 44.9 52.8 30˚ Lumens Avg 8'x10' initial 8'x10' Watts Catalog no. per watt footcandles* per sq. foot 84.0 82.5 80.6 78.4 34 42 48 55 0.38 0.40 0.56 0.66 OPS22GPW25A40ULAG OPS22GPW33A40ULAG OPS22GPW38A40ULAG OPS22GPW42A40ULAG For Air handling housing models substitute OPS22 for OPA22. * 42 Recessed LED Luminaires in a 60' x 56' x 9' room with a reflectance of 80/50/20, placed 8' x 10' on center. Footcandle readings are taken 2 ½' from floor level. Example OPS22G PW Opalescent Lens shielding LED PW = High light Direct transmission frost Recessed white acrylic lens. 40 • Can provide 48 initial footcandles at 0.56 watts per square foot. • Delivers 3619 lumens with just 44.9 input watts. Input watts (120V) 44.9W 24" (610mm) • Bold but simple 2 ½" regressed frame with contoured lens. U LAG 2 Lumen 1 Color temp 1,2 Voltage Driver Options 25A = 25k lm 40 = 4000K UNV = LAG = See page 4.5 33A = 33k lm 120-277V LED Driver 38A = 38k lm 42A = 42k lm 1. Approximate delivered values (Consult IES file). 2. Consult representative for other color temperature options and driver dimming options. • Integrated thermal management system conducts heat away from LEDs and transfers it to the surrounding environment. • Factory calibrated intelligent driver capable of providing various lumen outputs to balance energy savings with lighting application needs. • High efficiency LEDs have 50,000 hour rated life at L70. • Predicted L70 lifetime is based on LED manufacturer’s supplied LM-80 data and in-situ laboratory testing. • True mitered corner lens frame. • Door jamb finished black on four sides for positive light stop. • Spring loaded rooster head latches. • 18 gauge steel hinges. • 5" deep body. • Black body to dissipate heat from LEDs. • Earthquake/Hold-down clips. • Hemmed over side rails for maximum safety. • Construction to meet NYC Code Requirements or Chicago Plenum is available. • Not for continuous row mounting. • Five-year warranty on luminaire, LED boards and driver. Options & accessories Drywall kit: Conversion kit for 2' x 2' unit: FK92X2. Electrical wiring options: Consult factory. Fusing: Suffix: A (Internal fast-blow fusing). Suffix: C (Internal slow-blow fusing). Chicago Plenum: Suffix: C. Comprehensive lighting catalog 7th Edition 4.5 Linear recessed and surface lighting – Professional Skyway LED 2' x 2' Direct recessed air handling or static luminaires Skyway 2x2 LED’s modern triple lens design features a clear conical prismatic center lens complemented by frosted white acrylic side lenses. Alternating lens textures creates visual interest while shielding the LEDs from direct view and preventing pixilation. The soft, balanced, uniform brightness of Skyway make it ideal for office, institution and healthcare applications. Features • Aesthetically pleasing triple lens design. SKS22GPK33A40ULAG 5" (127mm) • Clear acrylic conical prismatic center lens. • Can provide 45 initial footcandles at 0.56 watts per square foot. • Delivers 3366 lumens with just 44.9 input watts. Candlepower Curve Reference data • Curved high light transmission frost white acrylic side lenses. Delivered lumens Efficiency lm/w 3366 75.0 LED Driver 600 24" (610mm) 1200 • Field replaceable LED array and drivers accessible from below. • Integrated thermal management system conducts heat away from LEDs and transfers it to the surrounding environment. • Factory calibrated intelligent driver capable of providing various lumen outputs to balance energy savings with lighting application needs. • High efficiency LEDs have 50,000 hour rated life at L70. • Predicted L70 lifetime is based on LED manufacturer’s supplied LM-80 data and in-situ laboratory testing. • Black body to dissipate heat from LEDs. • 5" deep body. • Earthquake/Hold-down clips. • Door jamb finished black on four sides for positive light stop. • True mitered corner aluminum lens frame. • Spring loaded rooster head latches. • 18 gauge steel hinges. • Construction to meet NYC Code Requirements or Chicago Plenum is available. • Not for continuous row mounting. • Five-year warranty on luminaire, LED boards and driver. Options & accessories 1800 Ordering information Type Size Static 2' x 2' Delivered lumens 2381 3366 3851 Input watts 30.4 44.9 52.8 30˚ Lumens Avg 8'x10' initial 8'x10' Watts Catalog no. per watt footcandles* per sq. foot 78.3 75.0 72.9 32 45 52 0.38 0.56 0.66 SKS22GPK25A40ULAG SKS22GPK33A40ULAG SKS22GPK38A40ULAG For Air handling housing models substitute SKS22 for SKA22. * 42 Recessed LED Luminaires in a 60' x 56' x 9' room with a reflectance of 80/50/20, placed 8' x 10' on center. Footcandle readings are taken 2 ½' from floor level. • Hemmed over side rails for maximum safety. • Fixture ends turned-in for safe handling. 60˚ Input watts (120V) 44.9W Example SKS22G Skyway LED Direct Recessed 40 Lens shielding PW = Pattern 19, 0.156 virgin acrylic center lens with frost white acrylic side lenses. PP = Frost white acrylic center lens with frost white acrylic side lenses. U LAG 2 Lumen Color temp Voltage Driver Options 25A = 25k lm 40 = 4000K UNV = LAG = See page 4.6 33A = 33k lm 120-277V LED Driver 38A = 38k lm 1 1,2 1. Approximate delivered values (Consult IES file). 2. Consult representative for other color temperature options and driver dimming options. Drywall kit: Conversion kit for 2' x 2' unit: FK92X2. Electrical wiring options: Consult factory. Fusing: Suffix: A (Internal fast-blow fusing). Suffix: C (Internal slow-blow fusing). Chicago Plenum: Suffix: C. 4.6 Philips Lightolier For complete specification information visit www.lightolier.com Professional – Linear recessed and surface lighting SpecPlus LED 2' x 2' Direct recessed static luminaires Easily transition into the new era of the Green office with the SpecPlus LED 2x2 lensed troffer. SpecPlus LED offers a 1/2" regressed extruded aluminum frame with spring loaded latches. The 9/16" wide frame trim gives a 500 square inch aperture. The lens is extruded acrylic, square base male conical prism of .156" overall thickness. Providing excellent obscuration of the light source while controlling volumetric illumination. Features SPS22GFSKA38A40ULAG Candlepower Curve Reference data 5" (127mm) Delivered lumens Efficiency lm/w • Prismatic acrylic lens. • Flat steel Door frame with 500 square inch lens opening. 3621 85.5 • Can provide 52 initial footcandles at 0.56 watts per square foot. LED Driver 60˚ 700 Input watts (120V) 44.9W 24" (610mm) • Field replaceable LED array and drivers accessible from below. 1400 2100 Ordering information Type Size Delivered lumens Input watts 30˚ Lumens Avg 8'x10' initial 8'x10' Watts Catalog no. per watt footcandles* per sq. foot Static 2' x 2' 30.0 38.4 44.9 52.8 84.4 82.5 80.6 78.4 35 43 50 57 0.38 0.48 0.56 0.66 SPS22GFSKA25A40ULAG SPS22GFSKA33A40ULAG SPS22GFSKA38A40ULAG SPS22GFSKA42A40ULAG 36 45 52 59 0.38 0.48 0.56 0.66 SPS22GFSVA25A40ULAG SPS22GFSVA33A40ULAG SPS22GFSVA38A40ULAG SPS22GFSVA42A40ULAG 35 44 50 58 0.38 0.48 0.56 0.66 SPS22GRAKA25A40ULAG SPS22GRAKA33A40ULAG SPS22GRAKA38A40ULAG SPS22GRAKA42A40ULAG Flat steel/aluminum Door frame with VA lens Static 2' x 2' 2722 3362 3841 4397 30.0 38.4 44.9 52.8 89.5 87.6 85.5 83.3 Static 2' x 2' 30.0 38.4 44.9 52.8 85.5 83.4 82.0 79.5 Static 2' x 2' 30.0 38.4 44.9 52.8 89.8 87.7 86.0 83.3 • Predicted L70 lifetime is based on LED manufacturer’s supplied LM-80 data and in-situ laboratory testing. • Black body to dissipate heat from LEDs. • 5" deep body. • Earthquake/Hold-down clips. • Spring loaded rooster head latches. • Construction to meet NYC Code Requirements or Chicago Plenum is available. • Not for continuous row mounting. • Five-year warranty on luminaire, LED boards and driver. Regressed aluminum Door frame with VA lens 2729 3358 3860 4397 • Factory calibrated intelligent driver capable of providing various lumen outputs to balance energy savings with lighting application needs. • Hemmed over side rails for maximum safety. Regressed aluminum Door frame with KA lens 2598 3194 3681 4199 • Integrated thermal management system conducts heat away from LEDs and transfers it to the surrounding environment. • High efficiency LEDs have 50,000 hour rated life at L70. Flat steel/aluminum Door frame with KA lens 2565 3158 3621 4140 • Delivers 3860 lumens with just 44.9 input watts. 37 45 52 59 SPS22GRAVA25A40ULAG SPS22GRAVA33A40ULAG SPS22GRAVA38A40ULAG SPS22GRAVA42A40ULAG 0.38 0.48 0.56 0.66 Options & accessories Drywall kit: Conversion kit for 2' x 2' unit: FK92X2. Electrical wiring options: Consult factory. Fusing: Suffix: A (Internal fast-blow fusing). Suffix: C (Internal slow-blow fusing). Chicago Plenum: Suffix: C. * 42 Recessed LED luminaires in a 60' x 56' x 9' room with a reflectance of 80/50/20, placed 8' x 10' on center. Footcandle readings are taken 2 ½' from floor level. Example SPS22G PW SpecPlus Lens frame Lens shielding LED FS = Flat steel frame KA = 0.156 prismatic Direct FA = Flat alum. frame acrylic lens recessed RA = Regressed VA = 0.095 prismatic aluminum. frame acrylic lens 40 U LAG 2 Lumen Color temp Voltage Driver Options 25A = 25k lm 40 = 4000K UNV = LAG = See page 4.7 33A = 33k lm 120-277V LED driver 38A = 38k lm 42A = 42k lm 1 1,2 1. Approximate delivered values (Consult IES file). 2. Consult representative for other color temperature options and driver dimming options. Comprehensive lighting catalog 7th Edition 4.7 Linear recessed and surface lighting – Professional HP90 Direct/indirect recessed luminaires 4.8 Philips Lightolier For complete specification information visit www.lightolier.com Professional – Linear recessed and surface lighting HP90 Direct/indirect recessed luminaires The HP90 family continues to grow. Now offered in T5 or T8 lamping as well as air supply and return capabilities. It's an excellent choice when choosing an architectural designed luminaire for LEED compliant office space. HP90 combines a recessed contoured body with an enclosed linear prismatic lens to create an efficient direct/indirect luminaire. HP90 will illuminate both vertical and horizontal surfaces creating balanced brightness. Comprehensive lighting catalog 7th Edition 4.9 Linear recessed and surface lighting – Professional HP90 T5 2' x 4' Direct/indirect recessed static luminaires HP90 combines a recessed contoured body with an enclosed linear prismatic lens to create a 90.4% efficient direct/indirect luminaire. HP90 has an excellent spacing ratio of 1.4 and will illuminate both vertical and horizontal surfaces creating balance brightness while consuming only .63 watts per square foot. It is available in 2' x 4', 2' x 2' and 1' x 4' sizes utilizing T5 lamps. An excellent choice when choosing an architectural designed luminaire for LEED compliant office spaces. The construction pays attention to fit and finish. Features • Can provide 54.6 maintained footcandles of balanced brightness illumination at only .68 watts per square foot. H9S2GLR228120WA 5" (127mm) • 90.4% efficient two lamp 28W T5 2' x 4' luminaire. • 84.6% efficient two lamp 54W T5HO 2' x 4' luminaire. • Direct/indirect appearance with soft contoured interior. • Lens encloses lamp compartment. • Translucent DR acrylic linear prismatic lens. • Tension screws secure ends to body. • Same fixture fits both G and T ceiling types. • Fits flush to face of slot grid (T) ceiling types. • Lamp shield opens from either side. • 95% reflective specular aluminum reflector. 24" (610mm) Electronic ballast 5" (127mm) Type Size Static 2' x 4' Example • Wiring access plate standard. Lamp qty –type Lamp watts 2-T5 28W H9S2GLR228 120 Voltage 120 = 120V 277 = 277V UNV= 120-277V Type Size Ballast type <10THD Static 2' x 4' PG Electronic T5 28W instant start WA*† Electronic T5 28W bi-level step ballast (2 lamp) VY DALI Ballast DA Example † 56 Input watts 0.93 B.F. DALI = digital addressable dimming Options See page 4.10 and page 4.130 Candlepower Curve Efficiency 84.6% Spacing ratio 1.4 800 1600 Lamp qty –type Lamp watts 2-T5HO H9S2GLR254 54W UNV Catalog no. H9S2GLR128UNVPG 2400 H9S2GLR254 PG Voltage 120 = 120V 277 = 277V UNV= 120-277V Ballast See page 4.10 A Candlepower Curve Efficiency 87.2% 5" 1.2 (127mm) Spacing ratio Electrical wiring options: Consult factory. For motion or light sensor see folio OA20-10. Fusing: Suffix: A (Internal fast-blow fusing). Suffix: C (Internal slow-blow fusing). 24" (610mm) Electronic ballast 5" (127mm) 300 Type Static Example Size 600 Lamp qty –type 2' x 4' Lamp watts 1-T5 1-T5HO H9S2GLR128 HP90 Direct/indirect Recessed 60˚ Input watts (120V) 31.6W Ballast factor 1.0 Ordering information Philips Lightolier 30˚ Options See page 4.10 and page 4.130 Reference data Drywall kit: Conversion kit for 2' x 4' unit: FK92X4. 4.10 60˚ Input watts (120V) 112.4W Ballast factor 1.0 HP90 Direct/indirect Recessed * Ballast (WA) only available in 120 or 277 volt. Ballast See page 4.10 30˚ A Electronic ballast 5" (127mm) Ordering information 24" (610mm) 1650 H9S2GLR228 Reference data 5" (127mm) page 4.130 Catalog no. WA H9S2GLR254UNVPG Finish: Chassis exterior – baked white acrylic enamel. Cavity – baked flat white acrylic enamel. Rust preventive undercoating. Reflector – low iridescence specular aluminum 95% reflectance. 60˚ 1100 • Construction to meet NYC Code or Chicago Plenum requirement available. Electronic T5 program start 550 Input watts (120V) 54.6W Ballast factor 0.93 HP90 Direct/indirect Recessed • Can be continuous row mounted. Options & accessories Efficiency 90.4% Spacing ratio 1.4 Ordering information • Ballast accessible from room side. • Optional DALI ballast iGEN technology accepts digital dimming commands from computers, scene controllers and automatic control devices. Candlepower Curve Reference data • 87.2% efficient single lamp 28W T5 2' x 4' luminaire. 28W 54W UNV Catalog no. 900 H9S2GLR128 H9S2GLR154 PG 30˚ A Voltage Ballast Options 120 = 120V See page 4.10 See page 4.10 277 = 277V and page 4.130 UNV= 120-277V For complete specification information visit www.lightolier.com Professional – Linear recessed and surface lighting HP90 T5 2' x 2' Direct/indirect recessed static luminaires HP90 combines a recessed contoured body with an enclosed linear prismatic lens to create an efficient direct/indirect luminaire. Features H9S2GLR1FTUNVPR Candlepower Curve Reference data Efficiency 72.9% 5" Spacing ratio 1.2 (127mm) Electronic ballast 24" (610mm) 5" (127mm) Type Static Example Size Lamp watts 1-TT5 HP90 Direct/indirect Recessed 40W UNV Voltage 120 = 120V 277 = 277V UNV= 120-277V H9S2GLR224UNVPG 900 H9S2GLR1FT Ballast See page 4.11 Static Example 2' x 2' • Can be continuous row mounted. • Wiring access plate standard. • Optional DALI ballast iGEN technology accepts digital dimming commands from computers, scene controllers and automatic control devices. Candlepower Curve Efficiency 80.3% Spacing ratio 1.4 Lamp watts 2-T5 2-T5HO 14W 24W UNV Voltage 120 = 120V 277 = 277V UNV= 120-277V Catalog no. 900 H9S2GLR214 H9S2GLR224 PG Ballast See page 4.11 • Construction to meet NYC Code or Chicago Plenum requirement available. Options & accessories 300 60˚ 600 H9S2GLR224 HP90 Direct/indirect Recessed • Ballast accessible from room side. Input watts (120V) 49.4W Ballast factor 1.0 Lamp qty –type • Fits flush to face of slot grid (T) ceiling types. • 95% reflective specular aluminum reflector. Options See page 4.11 and page 4.130 Ordering information Size 30˚ • Lamp shield opens from either side. Electronic ballast 5" (127mm) • Tension screws secure ends to body. A Reference data 5" (127mm) Type • Translucent DR acrylic linear prismatic lens. • Same fixture fits both G and T ceiling types. Catalog no. IB • Direct/indirect appearance with soft contoured interior. • Lens encloses lamp compartment. 600 H9S2GLR1FT 24" (610mm) • 80.3% efficient two lamp 24W T5HO 2' x 2' luminaire. 60˚ Input watts (120V) 37.6W Ballast factor 1.0 Lamp qty –type 2' x 2' • 83.2% efficient one lamp 14W T5 2' x 2' luminaire. 300 Ordering information • 72.9% efficient single lamp 40W twin tube T5 2' x 2' luminaire. A Options See page 4.11 and page 4.130 30˚ page 4.130 Finish: Chassis exterior – baked white acrylic enamel. Cavity – baked flat white acrylic enamel. Rust preventive undercoating. Reflector – low iridescence specular aluminum 95% reflectance. Ballast type <10THD <20THD Electronic T5 program start PG – Electronic TT5 40W PR* – Electronic TT5 40W IB SB Electronic TT5 50W BP – Electronic TT5 55W BF – Electronic T5 14W bi-level VY – step ballast (2 lamp) DALI Ballast DA – * Program start. DALI = digital addressable dimming Drywall kit: Conversion kit for 2' x 2' unit: FK92X2. Electrical wiring options: Consult factory. For motion or light sensor see folio OA20-10. Fusing: Suffix: A (Internal fast-blow fusing). Suffix: C (Internal slow-blow fusing). Comprehensive lighting catalog 7th Edition 4.11 Linear recessed and surface lighting – Professional HP90 T5 1' x 4' Direct/indirect recessed static luminaires HP90 combines a recessed contoured body with an enclosed linear prismatic lens to create an efficient direct/indirect luminaire. Features • 86.9% efficient one lamp 28W T5 1' x 4' luminaire. • 88.9% efficient two lamp 28W T5 1' x 4' luminaire. H9S1GLR228UNVPG • Direct/indirect appearance with soft contoured interior. Efficiency 88.9% Spacing ratio 1.4 5" (127mm) • Lens encloses lamp compartment. Electronic ballast • Translucent DR acrylic linear prismatic lens. • Same fixture fits both G and T ceiling types. • Lamp shield opens from either side. • 95% reflective specular aluminum reflector. • Ballast accessible from room side. Ordering information Type • Wiring access plate standard. • Optional DALI ballast iGEN technology accepts digital dimming commands from computers, scene controllers and automatic control devices. Example Options & accessories page 4.130 Size Lamp qty –type Lamp watts 2-T5 2-T5HO 1' x 4' H9S1GLR228 HP90 Direct/indirect Recessed • Construction to meet NYC Code or Chicago Plenum requirement available. Finish: Chassis exterior – baked white acrylic enamel. Cavity – baked flat white acrylic enamel. Rust preventive undercoating. Reflector – low iridescence specular aluminum 95% reflectance. PG Electronic T5 28W instant start WA*† Electronic T5 28W bi-level step ballast (2 lamp) VY DALI Ballast DA UNV PG Voltage 120 = 120V 277 = 277V UNV= 120-277V H9S1GLR128UNVPG † 30˚ Ballast See page 4.12 A Options See page 4.12 and page 4.130 Candlepower Curve Reference data Efficiency 86.9% Spacing ratio 1.4 5" (127mm) Electronic ballast 250 60˚ Input watts (120V) 32.6W Ballast factor 1.0 500 11 1516 (303mm) Ordering information Type * Ballast (WA) only available in 120 or 277 volt. 1800 Catalog no. H9S1GLR228 H9S1GLR254 28W 54W Ballast type <10THD Electronic T5 program start 60˚ 1200 11 1516 (303mm) Static • Can be continuous row mounted. 600 Input watts (120V) 63.3W Ballast factor 1.0 • Tension screws secure ends to body. • Fits flush to face of slot grid (T) ceiling types. Candlepower Curve Reference data • 86.5% efficient two lamp 54W T5HO 1' x 4' luminaire. Static Size Lamp qty –type 1' x 4' Lamp watts 1-T5 1-T5HO 750 Catalog no. 30˚ H9S1GLR128 H9S1GLR154 28W 54W 56 Input watts 0.93 B.F. DALI = digital addressable dimming Drywall kit: Conversion kit for 1' x 4' unit: FK91X4. Electrical wiring options: Consult factory. For motion or light sensor see folio OA20-10. Fusing: Suffix: A (Internal fast-blow fusing). Suffix: C (Internal slow-blow fusing) 4.12 Philips Lightolier Example H9S1GLR128 HP90 Direct/indirect Recessed 120 PG Voltage 120 = 120V 277 = 277V UNV= 120-277V Ballast See page 4.12 A Options See page 4.12 and page 4.130 For complete specification information visit www.lightolier.com Professional – Linear recessed and surface lighting HP90 T8 2' x 4' Direct/indirect recessed static luminaires HP90 T8 combines a recessed contoured body with an enclosed linear prismatic lens to create a 85.2% efficient direct/indirect luminaire. HP90 has an excellent spacing ratio of 1.4 and will illuminate both balanced vertical and horizontal surfaces creating balance brightness. It is available in 2' x 4', 2' x 2' and 1' x 4' sizes utilizing T8 lamps. An excellent choice when choosing an architectural designed luminaire for LEED compliant office spaces. The construction pays attention to fit and finish. Features • 85.2% efficient single lamp 32W T8 2' x 4' luminaire. H9S2GLR232UNVHI Candlepower Curve Reference data Efficiency 85.2% 5" 1.4 (127mm) Spacing ratio 24" (610mm) Electronic ballast 5" (127mm) Type Size Static 2' x 4' • Direct/indirect appearance with soft contoured interior. • Lens encloses lamp compartment. 550 60˚ Input watts (120V) 59.7W Ballast factor 0.88 • Translucent DR acrylic linear prismatic lens. • Tension screws secure ends to body. • Same fixture fits both G and T ceiling types. • Fits flush to face of slot grid (T) ceiling types. 1100 Ordering information • 85.2% efficient two lamp 32W T8 2' x 4' luminaire. • Lamp shield opens from either side. Lamp qty –type Lamp watts 2-T8 32W Catalog no. 1650 H9S2GLR232 • 95% reflective specular aluminum reflector. 30˚ • Ballast accessible from room side. • Can be continuous row mounted. Example H9S2GLR232 HP90 Direct/indirect Recessed UNV HI Voltage 120 = 120V 277 = 277V UNV= 120-277V Ballast See page 4.13 A • Wiring access plate standard. • Optional DALI ballast iGEN technology accepts digital dimming commands from computers, scene controllers and automatic control devices. Options See page 4.13 and page 4.130 • Construction to meet NYC Code or Chicago Plenum requirement available. Options & accessories H9S2GLR132UNVHI Candlepower Curve Reference data Efficiency 85.2% 5" 1.4 (127mm) Spacing ratio 24" (610mm) Electronic ballast 5" (127mm) 300 600 Ordering information Type Size Static 2' x 4' Example Lamp qty –type Lamp watts 1-T8 H9S2GLR132 HP90 Direct/indirect Recessed 60˚ Input watts (120V) 31.2W Ballast factor 0.88 32W UNV Voltage 120 = 120V 277 = 277V UNV= 120-277V Catalog no. 900 H9S2GLR132 HI Ballast See page 4.13 A Options See page 4.13 and page 4.130 30˚ page 4.130 Finish: Chassis exterior – baked white acrylic enamel. Cavity – baked flat white acrylic enamel. Rust preventive undercoating. Reflector – low iridescence specular aluminum 95% reflectance. Ballast type <10THD <20THD Electronic T8 (1 or 2 lamp) HI* SO* Electronic T8 (1 or 2 lamp) P2** – LOL Dimming T8 PS – Electronic T8 32W bi-level step ballast (2 lamp) V2 DALI Ballast DA – – * Instant start. Standard. ** Program start. DALI = digital addressable dimming Other dimming options consult factory. Note: For T8 UNV, you must use HI or P2 ballast code. Drywall kit: Conversion kit for 2' x 4' unit: FK92X4. Electrical wiring options: Consult factory. For motion or light sensor see folio OA20-10. Fusing: Suffix: A (Internal fast-blow fusing). Suffix: C (Internal slow-blow fusing) Comprehensive lighting catalog 7th Edition 4.13 Linear recessed and surface lighting – Professional HP90 T8 2' x 2' Direct/indirect recessed static luminaires HP90 T8 combines a recessed contoured body with an enclosed linear prismatic lens to create an efficient direct/indirect luminaire. Features • 82.5% efficient one lamp 17W T8 2' x 2' luminaire. • 80.3% efficient two lamp 17W T8 2' x 2' luminaire. • Direct/indirect appearance with soft contoured interior. H9S2GLR217UNVHI 5" (127mm) • Lens encloses lamp compartment. • Translucent DR acrylic linear prismatic lens. • Tension screws secure ends to body. 24" (610mm) • Same fixture fits both G and T ceiling types. • Fits flush to face of slot grid (T) ceiling types. Candlepower Curve Reference data Emergency Pack Efficiency 80.3% Spacing ratio 1.4 Electronic ballast 250 60˚ Input watts (120V) 30.6W Ballast factor 0.88 5" (127mm) 500 • Lamp shield opens from either side. Ordering information • 95% reflective specular aluminum reflector. Type Size • Ballast accessible from room side. Static 2' x 2' Lamp qty –type Lamp watts 2-T8 750 Catalog no. 30˚ H9S2GLR217 17W • Can be continuous row mounted. • Wiring access plate standard. • Optional DALI ballast iGEN technology accepts digital dimming commands from computers, scene controllers and automatic control devices. Example • Construction to meet NYC Code or Chicago Plenum requirement available. Options & accessories page 4.130 Finish: Chassis exterior – baked white acrylic enamel. Cavity – baked flat white acrylic enamel. Rust preventive undercoating. Reflector – low iridescence specular aluminum 95% reflectance. UNV HI Voltage 120 = 120V 277 = 277V UNV= 120-277V H9S2GLR117UNVHI PS – DALI Ballast DA – A Options See page 4.14 and page 4.130 Candlepower Curve Reference data 24" (610mm) Electronic ballast 5" (127mm) 120 60˚ Input watts (120V) 16.7W Ballast factor 0.88 HI*, P2** SO* LOL Dimming T8 Ballast See page 4.14 Efficiency 82.5% 5" 1.4 (127mm) Spacing ratio Ballast type <10THD <20THD Electronic T8 (1 or 2 lamp) H9S2GLR217 HP90 Direct/indirect Recessed 240 Ordering information * Instant start. Standard. Type Size ** Program start. Static 2' x 2' Lamp qty –type Lamp watts 1-T8 360 Catalog no. 30˚ H9S2GLR117 17W DALI = digital addressable dimming Other dimming options consult factory. Note: For T8 UNV, you must use HI or P2 ballast code. Drywall kit: Conversion kit for 2' x 2' unit: FK92X2. Electrical wiring options: Consult factory. For motion or light sensor see folio OA20-10. Example H9S2GLR117 HP90 Direct/indirect Recessed UNV HI Voltage 120 = 120V 277 = 277V UNV= 120-277V Ballast See page 4.14 A Options See page 4.14 and page 4.130 Fusing: Suffix: A (Internal fast-blow fusing). Suffix: C (Internal slow-blow fusing) 4.14 Philips Lightolier For complete specification information visit www.lightolier.com Professional – Linear recessed and surface lighting HP90 T8 1' x 4' Direct/indirect recessed static luminaires HP90 T8 combines a recessed contoured body with an enclosed linear prismatic lens to create an efficient direct/indirect luminaire. Features • 77.8% efficient one lamp 32W T8 1' x 4' luminaire. H9S1GLR232UNVHI Candlepower Curve Reference data Efficiency 78.4% Spacing ratio 1.4 5" (127mm) Electronic ballast 550 Input watts (120V) 59.4W Ballast factor 0.88 5" (127mm) Static 1' x 4' • Lens encloses lamp compartment. • Translucent DR acrylic linear prismatic lens. • Same fixture fits both G and T ceiling types. • Fits flush to face of slot grid (T) ceiling types. • Lamp shield opens from either side. Ordering information Size • Direct/indirect appearance with soft contoured interior. • Tension screws secure ends to body. 1100 12" (305mm) Type 60˚ • 78.4% efficient two lamp 32W T8 1' x 4' luminaire. 1650 Lamp qty –type Lamp watts 2-T8 32W 30˚ • 95% reflective specular aluminum reflector. Catalog no. • Ballast accessible from room side. H9S1GLR232 • Can be continuous row mounted. • Wiring access plate standard. Example H9S1GLR232 HP90 Direct/indirect Recessed UNV HI Voltage 120 = 120V 277 = 277V UNV= 120-277V Ballast See page 4.15 A Options See page 4.15 and page 4.130 Candlepower Curve Reference data Efficiency 77.8% Spacing ratio 1.5 5" (127mm) Electronic ballast 250 1' x 4' Electronic T8 (1 or 2 lamp) 1-T8 32W SO* PS – Electronic T8 32W bi-level step ballast (2 lamp) V2 – Catalog no. DALI Ballast DA – H9S1GLR132 * Instant start. Standard 750 Lamp watts HI*, P2** LOL Dimming T8 Ordering information Static Ballast type <10THD <20THD 500 12" (305mm) Lamp qty –type page 4.130 Finish: Chassis exterior – baked white acrylic enamel. Cavity – baked flat white acrylic enamel. Rust preventive undercoating. Reflector – low iridescence specular aluminum 95% reflectance. 60˚ Input watts (120V) 29.4W Ballast factor 0.88 5" (127mm) Size • Construction to meet NYC Code or Chicago Plenum requirement available. Options & accessories H9S1GLR132UNVHI Type • Optional DALI ballast iGEN technology accepts digital dimming commands from computers, scene controllers and automatic control devices. 30˚ ** Program start. Example H9S1GLR132 HP90 Direct/indirect Recessed UNV Voltage 120 = 120V 277 = 277V UNV= 120-277V HI Ballast See page 4.15 A Options See page 4.15 and page 4.130 DALI = digital addressable dimming Other dimming options consult factory. Note: For T8 UNV, you must use HI or P2 ballast code. Drywall kit: Conversion kit for 1' x 4' unit: FK91X4. Electrical wiring options: Consult factory. For motion or light sensor see folio OA20-10. Fusing: Suffix: A (Internal fast-blow fusing). Suffix: C (Internal slow-blow fusing) Comprehensive lighting catalog 7th Edition 4.15 Linear recessed and surface lighting – Professional HP90 Air 2' x 4' Direct/indirect recessed air handling luminaires HP90 Air combines a recessed contoured body with an enclosed linear prismatic lens to create an efficient direct/indirect luminaire with air supply or return capabilities. HP90 Air will illuminate both vertical and horizontal surfaces creating balance brightness. It is available5" in 2' x 4' and 2' x 2' sizes. An excellent choice when choosing an architectural designed (127mm) luminaire for LEED compliant office spaces. The construction pays attention to fit and finish. 21½" (546mm) Features • 90.4% efficient two lamp 28W T5 2' x 4' luminaire. H9A2GLR128UNVPG 24" (610mm) H9A2GLR228120WA • 85.2% efficient two lamp 32W T8 2' x 4' luminaire. 5" (127mm) • Direct/indirect appearance with soft contoured interior. • air supply or Return. • Air return model meets UL 1598, paragraph 9.2.2.5 requirements. 21½" (546mm) • Lens encloses lamp compartment. Candlepower Curve Efficiency 87.2% Spacing ratio 1.2 • Tension screws secure ends to body. • Same fixture fits both G and T ceiling types. • 95% reflective specular aluminum reflector. • Ballast accessible from room side. • Can be continuous row mounted. • Optional DALI ballast iGEN technology accepts digital dimming commands from computers, scene controllers and automatic control devices. • Construction to meet NYC Code or Chicago Plenum requirement available. page 4.130 Type Air supply and return Example PG – Electronic T5 28W instant start WA*† Electronic T5 28W bi-level step ballast (2 lamp) VY – Electronic T8 (1 or 2 lamp) HI*, P2** – SO* LOL Dimming T8 PS – Electronic T8 32W bi-level step ballast (2 lamp) V2 – DALI Ballast DA – * Instant start. Standard (WA Ballast only available in 120 or 277 volt) ** Program start. † 56 Input watts 0.93 B.F. 900 30˚ Lamp qty –type Lamp watts 1-T5 1-T5HO 2-T5 2-T5HO 2' x 4' H9A2GLR228 21½" (546mm) 1100 1650 30˚ Catalog no. H9A2GLR128 H9A2GLR154 H9A2GLR228 H9A2GLR254 PG A Ballast See page 4.16 5" (127mm) Options See page 4.16 and page 4.130 21½" (546mm) 24" (610mm) H9A2GLR232UNVHI Type Example Size 2' x 4' 24" (610mm) Reference data Candlepower Curve Efficiency 85.2% Spacing ratio 1.4 60˚ 5" 300 (127mm) 600 550 Electronic ballast Input watts (120V) 59.7W Ballast factor 0.88 60˚ 1100 24" (610mm) 900 30˚ Lamp qty –type Lamp watts Ordering information Air supply and return 5" (127mm) 21½" (546mm) Efficiency 85.2% Spacing ratio 1.4 Drywall kit: Conversion kit for 2' x 4' unit: FK92X4. Philips Lightolier UNV Voltage 120 = 120V 277 = 277V UNV= 120-277V Candlepower Curve Input watts (120V) 31.2W Ballast factor 0.88 21½" (546mm) 4.16 Input watts (120V) 54.6W Ballast factor 0.93 24" (610mm) Reference data Other dimming options consult factory. Fusing: Suffix: A (Internal fast-blow fusing). Suffix: C (Internal slow-blow fusing). 60˚ 550 Electronic ballast 5" (127mm) Electronic ballast Electrical wiring options: Consult factory. For motion or light sensor see folio OA20-10. 28W 54W 28W 54W H9A2GLR132UNVHI DALI = digital addressable dimming Note: For T8 UNV, you must use HI or P2 ballast code. Candlepower Curve 24" (610mm) HP90 Air Direct/indirect recessed air supply and return Ballast type <10THD <20THD Electronic T5 program start Size (127mm) 600 Ordering information • Wiring access plate standard. 60˚ 5" 300 Input watts (120V) 31.6W Ballast factor 1.0 21½" (546mm) • Lamp shield opens from either side. 24" (610mm) Reference data Efficiency 90.4% Spacing ratio 1.4 Electronic ballast • Fits flush to face of slot grid (T) ceiling types. Options & accessories 21½" (546mm) 24" (610mm) Reference data • Translucent DR acrylic linear prismatic lens. 5" (127mm) 1-T8 2-T8 H9A2GLR232 HP90 Air Direct/indirect recessed air supply and return 32W UNV 1650 30˚ Catalog no. H9A2GLR132 H9A2GLR232 HI A Voltage Ballast Options 120 = 120V See page 4.16 See page 4.16 277 = 277V and page 4.130 UNV= 120-277V For complete specification information visit www.lightolier.com Professional – Linear recessed and surface lighting HP90 Air 2' x 2' Direct/indirect recessed air handling luminaires HP90 Air combines a recessed contoured body with an enclosed linear prismatic lens to create an efficient direct/indirect luminaire with air supply or return capabilities. HP90 Air will illuminate both vertical and horizontal surfaces creating balance brightness. It is available 5" in 2' x 4' and 2' x 2' sizes. An excellent choice when choosing an architectural designed (127mm) luminaire for LEED compliant office spaces. The construction pays attention to fit and finish. 21½" (546mm) H9A2GLR1FTUNVPR 24" (610mm) 5" (127mm) 21½" (546mm) 21½" (546mm) Candlepower Curve Efficiency 72.9% Spacing ratio 1.2 Electronic ballast Air supply and return Example Size (127mm) 600 Reference data Candlepower Curve Input watts (120V) 49.4W Ballast factor 1.0 900 30˚ Lamp qty –type Lamp watts 1-TT5 2-T5 2-T5HO 2' x 2' H9A2GLR214 40W 14W 24W UNV HP90 Air Direct/indirect recessed air supply and return Voltage 120 = 120V 277 = 277V UNV= 120-277V H9A2GLR117UNVHI • Lamp shield opens from either side. • 95% reflective specular aluminum reflector. 30˚ • Wiring access plate standard. H9A2GLR1FT H9A2GLR214 H9A2GLR224 • Optional DALI ballast iGEN technology accepts digital dimming commands from computers, scene controllers and automatic control devices. • Construction to meet NYC Code or Chicago Plenum requirement available. A Options See page 4.17 and page 4.130 21½" (546mm) Candlepower Curve Efficiency 82.5% Spacing ratio 1.4 Type Example Size 2' x 2' 60˚ 5" 120 (127mm) 240 Candlepower Curve 250 Electronic ballast Input watts (120V) 30.6W Ballast factor 0.88 360 30˚ Lamp qty –type Lamp watts 1-T8 2-T8 H9A2GLR232 HP90 Air Direct/indirect recessed air supply and return 17W UNV 60˚ Voltage 120 = 120V 277 = 277V UNV= 120-277V Catalog no. BP – Electronic TT5 55W BF – Electronic T5 14W bi-level step ballast (2 lamp) VY – HI*, P2** SB SO* LOL Dimming T8 PS – DALI Ballast DA – ** Program start. DALI = digital addressable dimming Note: For T8 UNV, you must use HI or P2 ballast code. 30˚ Drywall kit: Conversion kit for 2' x 2' unit: FK92X2. Electrical wiring options: Consult factory. For motion or light sensor see folio OA20-10. Fusing: Suffix: A (Internal fast-blow fusing). Suffix: C (Internal slow-blow fusing). H9A2GLR117 H9A2GLR217 Ballast See page 4.17 IB Electronic TT5 50W Other dimming options consult factory. 500 750 HI PG – Electronic TT5 40W * Instant start. Standard 24" (610mm) Ordering information Air supply and return Reference data page 4.130 Electronic T5 program start Electronic T8 (1 or 2 lamp) 24" (610mm) Efficiency 80.3% Spacing ratio 1.4 Electronic ballast Input watts (120V) 16.7W Ballast factor 0.88 21½" (546mm) 5" (127mm) 21½" (546mm) Options & accessories Ballast type <10THD <20THD Emergency Pack 24" (610mm) Reference data 5" (127mm) 24" (610mm) 5" (127mm) 21½" (546mm) • Ballast accessible from room side. • Can be continuous row mounted. H9A2GLR217UNVHI Emergency Pack • Tension screws secure ends to body. • Fits flush to face of slot grid (T) ceiling types. 600 Catalog no. Ballast See page 4.17 • Lens encloses lamp compartment. • Same fixture fits both G and T ceiling types. 900 PG • Air return model meets UL 1598, paragraph. • Translucent DR acrylic linear prismatic lens. 60˚ 300 Electronic ballast • 80.3% efficient two lamp 24W T5HO 2' x 2' luminaire. • air supply or Return. 24" (610mm) 24" (610mm) Ordering information Type 60˚ 5" • 83.2% efficient one lamp 14W T5 2' x 2' luminaire. • Direct/indirect appearance with soft contoured interior. Efficiency 80.3% Spacing ratio 1.4 300 Input watts (120V) 37.6W Ballast factor 1.0 21½" (546mm) • 72.9% efficient single lamp 40W Twin tube T5 2' x 2' luminaire. 5" (127mm) 24" (610mm) Reference data Features H9A2GLR224UNVPG A Options See page 4.17 and page 4.130 Comprehensive lighting catalog 7th Edition 4.17 Linear recessed and surface lighting – Professional HP90 2' x 4' & 2' x 2' Direct/indirect semi-recessed static luminaires HP90 Drop Lens ~ Semi Recessed offers T5 lamp options in a body that is only recessed 2 ¼". The translucent linear prismatic lens and softly contoured body, create a pleasing architectural statement that is evenly illuminated. Its broad light distribution illuminates both horizontal and vertical surfaces, creating a soft balanced brightness in any space that enhances visual acuity. Features • Only 2-1/4" plenum depth. • 87.0% efficient single lamp 28W T5 2' x 4' luminaire. • 88.5% efficient two lamp 28W T5 2' x 4' luminaire. • 78.2% efficient single lamp 40W Twin tube T5 2' x 2' luminaire. • 77.1% efficient two lamp 24 watt T5 2' x 2' luminaire. • Direct/indirect appearance with soft contoured interior. • Same fixture fits both G and T ceiling types. • Fits flush to face of slot grid (T) ceiling. • Lens encloses lamp compartment. • Translucent DR acrylic linear prismatic lens. • Tension screws secure ends to body. • Lamp shield opens from either side. HDS2GLW228120WA • Wiring access plate standard. Electronic ballast • Optional DALI ballast iGEN Technology accepts digital dimming controllers, scene controllers and automatic control devices. • Construction to meet NYC Code or Chicago Plenum requirement available. Options & accessories 21½" (546mm) Type Size Ballast type <10THD 40W TT5 PR Electronic T5 program start PG Electronic T5 28W instant start WA*† Electronic T5 14W/28W bi-level step ballast (2 lamp) VY DALI Ballast DA Static 1000 Lamp qty –type 2' x 4' 21½" (546mm) Example Lamp watts 1-T5 2-T5 1-T5HO 2-T5HO 4 916" 28W (116mm) 28W 54W 54W HDS2GLW228 HP90 Semi-recessed Direct/indirect recessed static 21½" (546mm) 120 30˚ A Options See page 4.18 and page 4.130 Candlepower Curve Reference data Efficiency 78.2% 4 916" 1.4 (116mm) Spacing ratio 56 Input watts 0.93 B.F. Fusing: Suffix: A (Internal fast-blow fusing). Suffix: C (Internal slow-blow fusing). 1500 HDS2GLW128 HDS2GLW228 HDS2GLW154 HDS2GLW254 WA HDS2GLW1FTUNVPR DALI = digital addressable dimming Electrical wiring options: Consult factory. For motion or light sensor see folio OA20-10. Catalog no. Voltage 4 916" Ballast (116mm) See page 4.18 120 = 120V 277 = 277V UNV= 120-277V * Ballast (WA) only available in 120 or 277 volt. Drywall kit: C onversion kit for 2' x 4' unit: FK92X4. Conversion kit for 2' x 2' unit: FK92X2. 60˚ 500 Input watts (120V) 54.1W Ballast factor 0.93 Ordering information page 4.130 Finish: Chassis exterior – baked white acrylic enamel. Cavity – baked flat white acrylic enamel. Rust preventive undercoating. Reflector – low iridescence specular aluminum 95% reflectance. † Candlepower Curve Reference data Efficiency 88.5% 4 916" 1.4 (116mm) Spacing ratio • Ballast accessible from room side. 2 1/4Electronic (57mm)ballast 21½" (546mm) 2 5/16 250 24 (610mm) Ordering information Type Size Static 500 Lamp qty –type 2' x 2' Lamp watts UNV HP90 Semi-recessed 1 9/16 X 2 13/16 ACCESS Voltage Direct/indirect 120 = 120V PLATE W/ 2-7/8 DIA KO recessed static Catalog no. 750 (57mm) 2-T5 14W 2 1/4HDS2GLW214 2-T5HO 24W HDS2GLW224 2 5/16 (59mm) 1-Twin tube T5 40W HDS2GLW1FT 24 (610mm) HDS2GLW1FT Example 60˚ (59mm) Input watts (120V) 38.4W Ballast factor 1 PR Ballast See page 4.18 277 = 277V UNV= 120-277V 2 1/4 (57mm) 24 (610mm) 30˚ 1 9/16 X 2 PLATE W/ A Options See page 4.18 and page 4.130 24" 2 5/16 (59mm) (610mm) 4.18 Philips Lightolier 24 (610mm) For complete specification information2visit 1/4www.lightolier.com (57.15mm) 24 (610mm) 24" (1219mm) Professional – Linear recessed and surface lighting HP90 2' x 4' & 2' x 2' Direct/indirect surface-mounted static luminaires HP90 Drop Lens ~ Surface Mounted offers T5 lamp options in a body that is only 2-17/32" deep. The translucent linear prismatic lens and softly contoured body, create a pleasing architectural statement that is evenly illuminated. Its broad light distribution illuminates both horizontal and vertical surfaces, creating a soft balanced brightness in any space that enhances visual acuity. Features • 88.5% efficient two lamp 28W 2' x 4' luminaire. • 87.0% efficient single lamp 28W 2' x 4' luminaire. • 77.1% efficient two lamp 24W T5HO 2' x 2' luminaire. • 78.2% efficient single lamp 40W twin tube T5 2' x 2' luminaire. • Direct/indirect appearance with soft contoured interior. • Lens encloses lamp compartment. • Translucent DR acrylic linear prismatic lens. • Tension screws secure ends to body. • Lamp shield opens from either side. • Ballast accessible from room side. HDB2SLW228120WA Candlepower Curve Reference data Efficiency 88.5% 4 ⅞" 1.4 (123mm) Spacing ratio Electronic ballast 21½" (546mm) Static Size Lamp qty –type 2' x 4' 21½" (546mm) Example 1-T5 2-T5 1-T5HO 2-T5HO HDB2SLW228 HP90 Surface mounted Direct/indirect recessed static 21½" (546mm) Lamp watts 4 ⅞" 28W (123mm) 28W 54W 54W Catalog no. Options & accessories 1500 HDB2SLW128 HDB2SLW228 HDB2SLW154 HDB2SLW254 30˚ 120 WA Voltage 4 ⅞" 120 = (123mm) 120V 277 = 277V UNV= 120-277V Ballast See page 4.19 A Options See page 4.19 and page 4.130 21½" (546mm) Static Example 2-T5 2-T5HO 24 1/8 (613mm) 1-Twin tube T5 2' x 2' PR Electronic T5 program start PG Electronic T5 28W instant start WA*† Electronic T5 14W/28W bi-level step ballast (2 lamp) VY DALI Ballast DA 60˚ 56 Input watts 0.93 B.F. DALI = digital addressable dimming Electrical wiring options: Consult factory. For motion or light sensor see folio OA20-10. 2-7/8 DIA KO 2-1/4 MOUNTING HOLES 2 17/32 (64mm) Lamp watts Catalog no. 750 2 5/16 14W (59mm) HDB2SLW214 24W 40W 21 2 5/16 (59mm 1/8 (613mm) Fusing: Suffix: 24 A (Internal fast-blow fusing). Suffix: C (Internal slow-blow fusing). 500 2-1/4 MOUNTING HOLES HDB2SLW1FT UNV HP90 mounted 2-7/8 DIASurface KO Direct/indirect recessed static 250 Input watts (120V) 38.4W Ballast factor 1 24 1/8 (613mm) Lamp qty –type 40 W TT5 † Candlepower Curve Reference data 2 5/16 (59mm) Electronic ballast Size page 4.130 Finish: Chassis exterior – baked white acrylic enamel. Cavity – baked flat white acrylic enamel. Rust preventive undercoating. Reflector – low iridescence specular aluminum 95% reflectance. * Ballast (WA) only available in 120 or 277 volt. 4 ⅞" 2Efficiency 78.2% 17/32 (64mm) 1.4 (123mm) Spacing ratio Type • Construction to meet NYC Code or Chicago Plenum requirement available. Ballast type <10THD HDB2SLW1FTUNVPR Ordering information • Optional DALI ballast iGEN Technology accepts digital dimming controllers, scene controllers and automatic control devices. • Not for continuous row mounting. 1000 Ordering information Type 60˚ 500 Input watts (120V) 54.1W Ballast factor 0.93 • Built-in earthquake clips. 30˚ HDB2SLW224 HDB2SLW1FT PR Voltage Ballast 120 = 120V 2 17/32 See(64mm) page 4.19 277 = 277V (613mm) 24 1/8" 2 5/16 (59mm) UNV= 120-277V 24 1/8" (613mm) A Options See page 4.19 and page 4.130 21 2 5/16 (59mm 2 15/16" (75mm) 24 1/8 (613mm) 3 5/8" (92mm) 1 5/8" (41mm) 2 17/32 (64mm) 24 1/8 (613mm) 15 3/4" (400mm) 1 5/8" (41mm) Comprehensive lighting catalog 7th Edition 4.19 3 5/8" (92mm) 2-7/8 DIA KO 18 7/16" (468mm 2-1/4 MOUNTING HOLES Linear recessed and surface lighting – Professional Paraplus II 2' x 4' Direct/indirect louver air return or static recessed luminaires Paraplus II is an architecturally styled recessed luminaire that combines the features of a parabolic louver and an indirect cove to create an aesthetically pleasing direct/indirect appearance. PPH2G12FW332UNVH3 5" (127mm) Features • 67.8% efficient three lamp T8 2' x 4' luminaire. • 82.0% efficient two lamp T5 2' x 4' luminaire. • 72.1% efficient two lamp T8 2' x 4' luminaire. Ordering information Type Size Air return 2' x 4' • Fits flush to face of slot grid (T) ceiling. Static 2' x 4' Louver overlay Catalog no. 3-T8 P20 P20 & white overlay Matte white lens PPH2G12FW332 PPH2G12FO332 PPH2G12FM332 3-T8 P20 PPS2G12FW332 P20 & white overlay PPS2G12FO332 Matte white lens PPS2G12FM332 • Air return standard (meets UL requirements). • Static optional. Example • Louver hinges from either side. PPH2G12FW332 Paraplus Recessed direct/indirect • Can be continuous row mounted. • Wiring access plate standard. • Built in earthquake clips. UNV Voltage 120, 277 or UNV (120-277) 5" (127mm) Ballast type <10THD <20THD Electronic T8 HI*, P2** SO* 1 - 3 Lamp T8 H3*, P3** O3* Air return 2' x 4' ** Program start. Static 2' x 4' Drywall kit: Conversion kit for 2' x 4' unit: FK92X4. Emergency/wiring options: For special wiring, fusing, electronic dimming ballasts, consult factory. Example Louver overlay Catalog no. 2-T8 P20 P20 & white overlay Matte white lens PPH2G12FW232 PPH2G12FM232 PPH2G12FO232 2-T8 P20 PPS2G12FW232 P20 & white overlay PPS2G12FO232 Matte white lens PPS2G12FM232 PPH2G12FW232 Paraplus Recessed direct/indirect Packaging: Individual carton is standard. UNV HI Voltage 120, 277 or UNV (120-277) PPS2G12FW254UNVPG 2' x 4' Static 2' x 4' Example Philips Lightolier A Candlepower Curve 650 60˚ Input watts (120V) 120W 1300 Lamp qty –type Louver overlay Catalog no. 2-T5HO P20 P20 & white overlay Matte white lens PPS2G12FW254 PPS2G12FO254 PPS2G12FM254 2-T5 P20 PPS2G12FW228 P20 & white overlay PPS2G12FO228 Matte white lens PPS2G12FM228 PPS2G12FW254 Paraplus Recessed direct/indirect 4.20 30˚ Efficiency 82.0% Spacing ratio 1.3 Ordering information Air return 60˚ Ballast Options See page 4.20 See page 4.20 and page 4.130 Electronic ballast 24" (610mm) Size 1950 Reference data 5" (127mm) Type 650 1300 Lamp qty –type Electronic T5 PG – * Instant start. Candlepower Curve Efficiency 72.1% Spacing ratio 1.3 Ordering information Size A Input watts (120V) 62W 24" (610mm) Type 30˚ Ballast Options See page 4.20 See page 4.20 and page 4.130 Electronic ballast Ballast: Specify voltage (120, 277 or UNV) and type and add as suffix, e.g. UNVHI. 2550 Reference data page 4.130 Fusing: Suffix: A (Internal fast-blow fusing). Suffix: C (Internal slow-blow fusing). H3 PPH2G12FW232UNVHI • Housing is available in 20 gauge steel that meets NYC requirements. 60˚ 1700 Lamp qty –type • Only 5" deep. • Same fixture fits both G and T ceiling types. 850 Input watts (120V) 85W 24" (610mm) • 12 cell flat white louver with prismatic lens overlay. Options & accessories Efficiency 67.8% Spacing ratio 1.3 Electronic ballast • Direct/indirect louver appearance with soft contoured interior. Candlepower Curve Reference data UNV PG Voltage 120, 277 or UNV (120-277) 1950 30˚ A Ballast Options See page 4.20 See page 4.20 and page 4.130 For complete specification information visit www.lightolier.com Professional – Linear recessed and surface lighting Paraplus II 2' x 2' Direct/indirect louver air return or static recessed luminaires Paraplus II is an architecturally styled recessed luminaire that combines the features of a parabolic louver and an indirect cove to create an aesthetically pleasing direct/indirect appearance. PPH2G8FW2FT120SB Efficiency 72.0% Spacing ratio 1.3 Electronic ballast Air return Static Lamp qty –type 2' x 2' 2' x 2' 60˚ Louver overlay Catalog no. 2-TT5 P20 P20 & white overlay Matte white lens PPH2G8FW2FT PPH2G8FO2FT PPH2G8FM2FT 2-TT5 P20 PPS2G8FW2FT P20 & white overlay PPS2G8FO2FT Matte white lens PPS2G8FM2FT • Direct/indirect louver appearance with soft contoured interior. • 8 cell flat white louver with prismatic lens overlay. 1400 Ordering information Size Features 700 Input watts (120V) 72.6W 24" (610mm) Type Candlepower Curve Reference data 5" (127mm) • 72.0% efficient two lamp TT5 2' x 2' luminaire. • 71.4% efficient two lamp T5HO 2' x 2' luminaire. 2100 30˚ • Only 5" deep. • Same fixture fits both G and T ceiling types. • Fits flush to face of slot grid (T) ceiling. • Air return standard (meets UL requirements). • Static optional. • Louver hinges from either side. • Can be continuous row mounted. Example PPH2G8FW2FT Paraplus Recessed direct/indirect 120 SB Voltage 120, 277 or UNV (120-277) Ballast Options See page 4.21 See page 4.21 and page 4.130 Efficiency 71.4% Spacing ratio 1.2 Electronic ballast 60˚ Lamp qty –type Louver overlay Catalog no. 2-T5 P20 P20 & white overlay Matte white lens PPS2G8FW214 PPS2G8FO214 PPS2G8FM214 2-T5HO P20 PPS2G8FW224 P20 & white overlay PPS2G8FO224 Matte white lens PPS2G8FM224 2-T8 P20 P20 & white overlay Matte white lens 3-T8 P20 PPS2G8FW317 P20 & white overlay PPS2G8FO317 Matte white lens PPS2G8FM317 2' x 2' PPS2G8FW224 Paraplus Recessed direct/indirect • Housing is available in 20 gauge steel that meets NYC requirements. Voltage 120, 277 or UNV (120-277) PG Ballast type <10THD <20THD Electronic T8 HI*, P2** SO* 1 - 3 Lamp T8 H3*, P3** O3* SB* Electronic T5 PG – 1350 30˚ * Instant start. ** Program start. Drywall kit: Conversion kit for 2' x 2' unit: FK92X2. Emergency/wiring options: For special wiring, fusing, electronic dimming ballasts, consult factory. Packaging: Individual carton is standard. PPS2G8FW217 PPS2G8FO217 PPS2G8FM217 UNV page 4.130 Ballast: Specify voltage (120, 277 or UNV) and type and add as suffix, e.g. UNVHI. Electronic TT5 IB* 900 Ordering information Example 450 Input watts (120V) 56.9W 24" (610mm) Static Candlepower Curve Reference data 5" (127mm) Size • Built in earthquake clips. Options & accessories PPS2G8FW224UNVPG Type • Wiring access plate standard. A Fusing: Suffix: A (Internal fast-blow fusing). Suffix: C (Internal slow-blow fusing). A Ballast Options See page 4.21 See page 4.21 and page 4.130 Comprehensive lighting catalog 7th Edition 4.21 Linear recessed and surface lighting – Professional Paraplus II 1' x 4' Direct/indirect louver air return or static recessed luminaires Paraplus II is an architecturally styled recessed luminaire that combines the features of a parabolic louver and an indirect cove to create an aesthetically pleasing direct/indirect appearance. PPH1G6FW232UNVHI Features 600 12" (305mm) • 60.2% efficient two lamp T8 1' x 4' luminaire. • 67.5% efficient single lamp T5HO 1' x 4' luminaire. • 71.4% efficient two lamp T5HO 1' x 4' luminaire. • Only 5" deep. • Same fixture fits both G and T ceiling types. 1200 Type Size Lamp qty –type 1' x 4' • Static optional. Example • Louver hinges from either side. 2-T8 PPH1G6FW232 Paraplus Recessed direct/indirect • Can be continuous row mounted. • Wiring access plate standard. • 4 earthquake clips standard. • Housing is 20 gauge steel, meets NYC requirements. Louver overlay 1800 Catalog no. UNV HI Voltage 120 = 120V 277 = 277V UNV= 120-277V Ballast See page 4.22 A Options See page 4.22 and page 4.130 page 4.130 Ballast: Specify voltage (120, 277 or UNV) and type and add as suffix, e.g. UNVHI. PPS1G6FW154UNVPG Ballast type <10THD <20THD HI*, P2** Efficiency 67.5% Spacing ratio 1.2 5" (127mm) SO* Candlepower Curve Reference data Electronic ballast Electronic T5 PG – 550 12" (305mm) 1100 ** Program start. Drywall kit: Conversion kit for 1' x 4' unit: FK91X4. Emergency/wiring options: For special wiring, fusing, electronic dimming ballasts, consult factory. Ordering information Type Size Packaging: Individual carton is standard. Fusing: Suffix: A (Internal fast-blow fusing). Suffix: C (Internal slow-blow fusing). 60˚ Input watts (120V) 60.7W * Instant start. Static Example 1' x 4' Lamp qty –type 1650 Louver overlay Catalog no. 2-T5HO P20 P20 & white overlay Matte white lens PPS1G6FW254 PPS1G6FO254 PPS1G6FM254 1-T5HO P20 PPS1G6FW154 P20 & white overlay PPS1G6FO154 Matte white lens PPS1G6FM154 2-T5 P20 PPS1G6FW228 P20 & white overlay PPS1G6FO228 Matte white lens PPS1G6FM228 PPS1G6FW154 Paraplus Recessed direct/indirect Philips Lightolier 30˚ P20 PPH1G6FW232 P20 & white overlay PPH1G6FO232 Matte white lens PPH1G6FM232 • Air return standard (meets UL requirements). 4.22 60˚ Ordering information Air return • Fits flush to face of slot grid (T) ceiling. Electronic T8 Electronic ballast Input watts (120V) 64.1W • 6 cell flat white louver with prismatic lens overlay. Options & accessories Efficiency 60.2% Spacing ratio 1.1 5" (127mm) •Direct/indirect louver appearance with soft contoured interior. Candlepower Curve Reference data UNV PG Voltage 120 = 120V 277 = 277V UNV= 120-277V Ballast See page 4.22 30˚ A Options See page 4.22 and page 4.130 For complete specification information visit www.lightolier.com Professional – Linear recessed and surface lighting Paraplus II Direct/indirect louver air return or static recessed luminaires Comprehensive lighting catalog 7th Edition 4.23 Linear recessed and surface lighting – Professional Opalescent Premium specification recessed air handling or static luminaires Opalescent’s 2 ½" regressed frame with contoured lens, made of a high light transmission frost white acrylic, creates a bold but simple appearance that will blend with any architectural environment. The Opalescent lens frame assembly, designed with precision mitered side rails and integrated spring loaded latches, allows for simple installation and maintenance of the lamps and ballast. The exterior of the Opalescent housing is black and incorporates eyeleted heat removal vents on the end caps, creating an environment for a cooler ballast operating temperature. The internal reflector system is powder coated with our 95% reflective white paint. When matched with the high light transmission frost white acrylic lens it gives the Opalescent efficiencies that qualify for many rebate programs, making it a true energy and cost saving choice. 4.24 Philips Lightolier For complete specification information visit www.lightolier.com Professional – Linear recessed and surface lighting Opalescent T5 2' x 4' Premium specification recessed air handling or static luminaires Opalescent’s 2 ½" regressed frame with contoured lens, made of a high light transmission frost white acrylic, creates a bold but simple appearance that will blend with any architectural environment. The Opalescent lens frame assembly, designed with precision mitered side rails and integrated spring loaded latches, allows for simple installation and maintenance of the lamps and ballast. The exterior of the Opalescent housing is black and incorporates eyeleted heat removal vents on the end caps, creating an environment for a cooler ballast operating temperature. The internal reflector system is powder coated with our 95% reflective white paint. When matched with the high light transmission frost white acrylic lens it gives the Opalescent efficiencies that qualify for many rebate programs, making it a true energy and cost saving choice. Features • Bold but simple 2-1/2" regressed frame with contoured lens. • High light transmission frost white acrylic lens. • True mitered corner lens frame. • 86.8% efficient two lamp 28W T5 2' x 4' luminaire. • 79.5% efficient two lamp 54W T5HO 2' x 4' luminaire. • Internal reflector coated with 95% reflective white paint. OPA2GPW228UNVPG 5" (127mm) Type Size Lamp qty –type Lamp watts Catalog no. Static 2' x 4' 2-T5 28W OPS2GPW228 Air handling 2' x 4' 2-T5 28W OPA2GPW228 5" (127mm) 5" UNV (127mm) OPA2GPW228 24" (610mm) Opalescent 24" (610mm) Frost white contoured lens design Air handling or static PG Voltage 120 = 120V 277 = 277V UNV= 120-277V OPA2GPW254UNVPG Ballast See page 4.25 Lamp qty –type Lamp watts Catalog no. Static 2' x 4' 2-T5HO 54W OPS2GPW254 Air handling 2' x 4' 2-T5HO 54W OPA2GPW254 OPA2GPW254 Opalescent Frost white contoured lens design Air handling or static UNV Voltage 120 = 120V 277 = 277V UNV= 120-277V PG Ballast See page 4.25 • Spring loaded rooster head latches. • 18 gauge steel hinges. • Construction to meet NYC Code Requirements or Chicago Plenum is available. A Options & accessories Options See page 4.25 and page 4.130 Candlepower Curve 950 page 4.130 Ballast type <10THD 60˚ Electronic T5 program start PG Electronic T5 28W instant start WA*† Electronic T5 28W bi-level step ballast (2 lamp) VY DALI Ballast DA * Ballast (WA) only available in 120 or 277 volt. † 56 Input watts 0.93 B.F. DALI = digital addressable dimming 1900 Ordering information Example 30˚ Input watts (120V) 115.0W Ballast factor 1 24" (610mm) Size • Door jamb finished black on four sides for positive light stop. Efficiency 79.5% Spacing ratio 1.3 Electronic ballast • Hemmed over side rails for maximum safety. • Built-in earthquake clips. 1950 Reference data 5" (127mm) • Eyeleted heat removal vents in fixture ends. • Fixture ends turned-in for safe handling. 1300 Ordering information Type 60˚ 650 Input watts (120V) 62.7W Ballast factor 1 24" (610mm) • 5" deep body. • Black housing exterior for cooler ballast operating temperature. Efficiency 86.8% Spacing ratio 1.3 Electronic ballast Example Candlepower Curve Reference data 2850 Drywall kit: Conversion kit for 2' x 4' unit: FK92X4. 30˚ Emergency/wiring options: For special wiring, fusing, electronic dimming ballasts, consult factory. Fusing: Suffix: A (Internal fast-blow fusing). Suffix: C (Internal slow-blow fusing). A Options See page 4.25 and page 4.130 Comprehensive lighting catalog 7th Edition 4.25 Linear recessed and surface lighting – Professional Opalescent T5 2' x 2' Premium specification recessed air handling or static luminaires Opalescent’s 2 ½" regressed frame with contoured lens, made of a high light transmission frost white acrylic, creates a bold but simple appearance that will blend with any architectural environment. The Opalescent lens frame assembly, designed with precision mitered side rails and integrated spring loaded latches, allows for simple installation and maintenance of the lamps and ballast. The exterior of the Opalescent housing is black and incorporates eyeleted heat removal vents on the end caps, creating an environment for a cooler ballast operating temperature. The internal reflector system is powder coated with our 95% reflective white paint. When matched with the high light transmission frost white acrylic lens it gives the Opalescent efficiencies that qualify for many rebate programs, making it a true energy and cost saving choice. Features • Aesthetically pleasing triple lens design. • Curved high light transmission frost white acrylic side lenses. • Clear acrylic conical prismatic center lens. • Internal reflector coated with 95% reflective white paint. • 82.8% efficient two lamp 40W TT5 2' x 2' luminaire. • 75.6% efficient two lamp 14W T5 2' x 2' luminaire. OPS2GPW2FTUNVPR 5" (127mm) • 5" deep body. • Black housing exterior for cooler ballast operating temperature. • Hemmed over side rails for maximum safety. Efficiency 82.8% Spacing ratio 1.3 Electronic ballast 1300 Ordering information • Fixture ends turned-in for safe handling. • Built-in earthquake clips. Type Size Lamp qty –type Lamp watts • Door jamb finished black on four sides for positive light stop. Static 2' x 2' 2-Twin tube T5 40W OPS2GPW2FT Air handling 2' x 2' 2-Twin tube T5 40W OPA2GPW2FT • True mitered corner aluminum lens frame. Catalog no. 1950 30˚ 5" (127mm) • Spring loaded rooster head latches. OPS2GPW2FT Example • 18 gauge steel hinges. 24" (610mm) • Construction to meet NYC Code Requirements or Chicago Plenum is available. Options & accessories 60˚ 650 Input watts (120V) 67.4W Ballast factor 0.88 24" (610mm) • Eyeleted heat removal vents in fixture ends. Candlepower Curve Reference data • 76.1% efficient two lamp 24W T5HO 2' x 2' luminaire. Opalescent Frost white contoured lens design 24" (610mm) Air handling or static page 4.130 UNV 5" (127mm) PR Voltage 120 = 120V 277 = 277v UNV= 120-277V Ballast See page 4.26 A Options See page 4.26 and page 4.130 Ballast type <10THD <20THD Electronic T5 program start PG – Electronic TT5 40W PR* – Electronic TT5 40W IB SB Electronic TT5 50W BP – Electronic TT5 55W BF – OPA2GPW224UNVPG 5" (127mm) DALI Ballast DA – * Program start. DALI = digital addressable dimming Type Size Fusing: Suffix: A (Internal fast-blow fusing). Suffix: C (Internal slow-blow fusing). Lamp qty –type Static 2' x 2' Air handling 2' x 2' 2-T5 2-T5HO Lamp watts OPA2GPW224 Opalescent Frost white contoured lens design Air handling or static 4.26 Philips Lightolier 60˚ 800 2-T5 2-T5HO Example 400 Input watts (120V) 51.1W Ballast factor 1 Ordering information Drywall kit: Conversion kit for 2' x 2' unit: FK92X2. Emergency/wiring options: For special wiring, fusing, electronic dimming ballasts, consult factory. Efficiency 76.1% Spacing ratio 1.3 Electronic ballast 24" (610mm) Electronic T5 14W bi-level VY – step ballast (2 lamp) Candlepower Curve Reference data Catalog no. 14W 24W OPS2GPW214 OPS2GPW224 14W 24W OPA2GPW214 OPA2GPW224 UNV Voltage 120 = 120V 277 = 277V UNV= 120-277V PG Ballast See page 4.26 1200 30˚ A Options See page 4.26 and page 4.130 For complete specification information visit www.lightolier.com Professional – Linear recessed and surface lighting Opalescent T8 2' x 4' Premium specification recessed air handling or static luminaires Opalescent’s 2 ½" regressed frame with contoured lens, made of a high light transmission frost white acrylic, creates a bold but simple appearance that will blend with any architectural environment. The Opalescent lens frame assembly, designed with precision mitered side rails and integrated spring loaded latches, allows for simple installation and maintenance of the lamps and ballast. The exterior of the Opalescent housing is black and incorporates eyeleted heat removal vents on the end caps, creating an environment for a cooler ballast operating temperature. The internal reflector system is powder coated with our 95% reflective white paint. When matched with the high light transmission frost white acrylic lens it gives the Opalescent efficiencies that qualify for many rebate programs, making it a true energy and cost saving choice. Features • Bold but simple 2 ½" regressed frame with contoured lens. • High light transmission frost white acrylic lens. • True mitered corner lens frame. • 80.8% efficient two lamp 32W T8 2' x 4' luminaire. • 80.0% efficient three lamp 25W T8 2' x 4' luminaire. OPA2GPW232UNVC5 Candlepower Curve Reference data 5" (127mm) Efficiency 80.8% Spacing ratio 1.3 Electronic ballast 60˚ 650 Input watts (120V) 53.5W Ballast factor 0.77 24" (610mm) • Black housing exterior for cooler ballast operating temperature. • Eyeleted heat removal vents in fixture ends. • Fixture ends turned-in for safe handling. • Built-in earthquake clips. Type Size Static 2' x 4' 2-T8 32W OPS2GPW232 Air handling 2' x 4' 2-T8 32W Lamp qty –type Lamp watts Catalog no. OPA2GPW232 1950 30˚ OPA2GPW232 UNV 5" 24" (610mm) Opalescent Frost white contoured lens design 24" (610mm) Air handling or static C5 (127mm) Voltage 120 = 120V 277 = 277V UNV= 120-277V Ballast See page 4.27 • Door jamb finished black on four sides for positive light stop. • Spring loaded rooster head latches. • 18 gauge steel hinges. 5" (127mm) Example • 5" deep body. • Hemmed over side rails for maximum safety. 1300 Ordering information • Internal reflector coated with 95% reflective white paint. • Construction to meet NYC Code Requirements or Chicago Plenum is available. A Options See page 4.27 and page 4.130 Options & accessories page 4.130 Ballast: Specify voltage (120, 277 or UNV) and type and add as suffix, e.g. UNVHI. Ballast type <10THD <20THD OPA2GPW332UNVH3 5" (127mm) 950 60˚ 1900 Type Size Lamp qty –type Lamp watts Static 2' x 4' 3-T8 32W OPS2GPW332 Air handling 2' x 4' 3-T8 32W OPA2GPW332 OPA2GPW332 Opalescent Frost white contoured lens design Air handling or static Catalog no. UNV Voltage 120 = 120V 277 = 277V UNV= 120-277V H3 Ballast See page 4.27 HI, P2** SO* 1 - 3 Lamp T8 H3*, P3** O3* C5* – * Instant start. ** Program start. Input watts (120V) 71.1W Ballast factor 0.88 Ordering information Electronic T8 Advance Optanium Low Watt.77 Electronic T8 Efficiency 80.0% Spacing ratio 1.3 Electronic ballast 24" (610mm) Example Candlepower Curve Reference data – 25W 2850 Drywall kit: Conversion kit for 2' x 4' unit: FK92X4. 30˚ Emergency/wiring options: For special wiring, fusing, electronic dimming ballasts, consult factory. Packaging: Individual carton is standard. Fusing: Suffix: A (Internal fast-blow fusing). Suffix: C (Internal slow-blow fusing). A Options See page 4.27 and page 4.130 Comprehensive lighting catalog 7th Edition 4.27 Linear recessed and surface lighting – Professional Opalescent T8 2' x 2' Premium specification recessed air handling or static luminaires Features • Aesthetically pleasing triple lens design. • Curved high light transmission frost white acrylic side lenses. • Clear acrylic conical prismatic center lens. Opalescent’s 2 ½" regressed frame with contoured lens, made of a high light transmission frost white acrylic, creates a bold but simple appearance that will blend with any architectural environment. The Opalescent lens frame assembly, designed with precision mitered side rails and integrated spring loaded latches, allows for simple installation and maintenance of the lamps and ballast. The exterior of the Opalescent housing is black and incorporates eyeleted heat removal vents on the end caps, creating an environment for a cooler ballast operating temperature. The internal reflector system is powder coated with our 95% reflective white paint. When matched with the high light transmission frost white acrylic lens it gives the Opalescent efficiencies that qualify for many rebate programs, making it a true energy and cost saving choice. • Internal reflector coated with 95% reflective white paint. • 74.5% efficient two lamp 17W T8 2' x 2' luminaire. • 70.1% efficient three lamp 17W T8 2' x 2' luminaire. OPA2GPW217UNVHI 5" (127mm) • Black housing exterior for cooler ballast operating temperature. • Hemmed over side rails for maximum safety. • Door jamb finished black on four sides for positive light stop. • True mitered corner aluminum lens frame. • Spring loaded rooster head latches. • 18 gauge steel hinges. • Construction to meet NYC Code Requirements or Chicago Plenum is available. Options & accessories 600 Ordering information • Built-in earthquake clips. Type Size Lamp qty –type Static 2' x 2' 2-T8 2-6" U T8 Air handling 2' x 2' 2-T8 2-6" U T8 page 4.130 Lamp watts 24" (610mm) OPA2GPW217 Example Catalog no. OPS2GPW217 OPS2GPW26U 17W 32W 17W5" OPA2GPW217 (127mm) 32W OPA2GPW26U 5" UNV (127mm) Opalescent Frost white contoured lens design 24" (610mm) Air handling or static Ballast: Specify voltage (120, 277 or UNV) and type and add as suffix, e.g. UNVHI. 60˚ 300 Input watts (120V) 30.2W Ballast factor 0.90 24" (610mm) • Fixture ends turned-in for safe handling. Efficiency 74.5% Spacing ratio 1.3 Electronic ballast • Eyeleted heat removal vents in fixture ends. Candlepower Curve Reference data • 5" deep body. HI Voltage 120 = 120V 277 = 277V UNV= 120-277V Ballast See page 4.28 900 30˚ A Options See page 4.28 and page 4.130 Ballast type <10THD <20THD Electronic T8 HI*, P2** SO* 1 - 3 Lamp T8 H3*, P3** O3* OPA2GPW317UNVH3 5" (127mm) ** Program start. Efficiency 70.1% Spacing ratio 1.3 Electronic ballast Drywall kit: Conversion kit for 2' x 2' unit: FK92X2. Emergency/wiring options: For special wiring, fusing, electronic dimming ballasts, consult factory. Packaging: Individual carton is standard. Fusing: Suffix: A (Internal fast-blow fusing). Suffix: C (Internal slow-blow fusing). Philips Lightolier 60˚ 900 Ordering information Type Size Static 2' x 2' Lamp qty –type 3-T8 Lamp watts 17W OPS2GPW317 Air handling 2' x 2' 3-T8 17W OPA2GPW317 OPA2GPW317 Opalescent Frost white contoured lens design Air handling or static 4.28 450 Input watts (120V) 45.5W Ballast factor 0.92 24" (610mm) Example Candlepower Curve Reference data * Instant start. Catalog no. UNV Voltage 120 = 120V 277 = 277V UNV= 120-277V H3 Ballast See page 4.28 1350 30˚ A Options See page 4.28 and page 4.130 For complete specification information visit www.lightolier.com Professional – Linear recessed and surface lighting Opalescent Twin 2' x 4' & 2' x 2' Premium specification recessed luminaires Dual sculptured ends and curved opal prismatic lens, presented in a shallow regressed Door frame the Opalescent Twin provides a broad distribution that illuminates the vertical and horizontal surfaces in the work space. This creates a soft, balanced brightness that enhances the ability to see and work. The Opalescent Twin provides illumination at power levels below LEED requirements and yet is a highly efficient luminaire. With a shallow depth of only 3 ½", access to the ballast from below, the Opalescent Twin is an excellent choice for any commercial application and a welcome part of the Opalescent family. The Opalescent Twin will be available with two high performance T8 lamps, as well as T5 and T5HO fluorescent lamps in the 2' x 4', and T8, T5, T5HO or TT5 fluorescent lamps in the 2' x 2', both sizes will also be offered with LED options. Opalescent Twin will fit standard grid and dry wall ceilings with use of optional FK Dry wall kit. Available 4th quarter 2011 OTS2GPW232UNVHI Ordering information Type Size Lamp qty –type Static 2' x 4' 2-T8 2-T5 2-T5HO Static 2' x 2' 2-T5 2-T8 2-T5HO 2-TT5 Lamp watts Catalog no. 32W 28W 54W OTS2GPW232UNVHI OTS2GPW228UNVPG OTS2GPW254UNVPG 14W 17W 24W 40W OTS2GPW214UNVPG OTS2GPW217UNVHI OTS2GPW224UNVPG OTS2GPW2FTUNVPR Comprehensive lighting catalog 7th Edition 4.29 Linear recessed and surface lighting – Professional Skyway T5 2' x 4' Premium specification recessed air handling or static luminaires Skyway’s aesthetically pleasing triple lens design features a clear conical prismatic center lens, enhanced by softly curved frost white acrylic lenses on each side, mounted in a regressed extruded aluminum frame with spring loaded latches. These 85% light transmission lenses, coupled with an internal reflector system coated with our 95% reflective white paint, creates our new, energy efficient Skyway. SKS2GPK228120WA Features • Aesthetically pleasing triple lens design. Candlepower Curve Reference data • Curved high light transmission frost white acrylic side lenses. 5" (127mm) Efficiency 73.0% Spacing ratio 1.2 Electronic ballast • Clear acrylic conical prismatic center lens. • Internal reflector coated with 95% reflective white paint. 650 1300 • 73% efficient two lamp 28W T5 2' x 4' luminaire. • 72.7% efficient two lamp 54W T5HO 2' x 4' luminaire. • 5" deep body. Ordering information Type • Black housing exterior for cooler ballast operating temperature. Size Static Lamp qty –type Air handling • Fixture ends turned-in for safe handling. 2' x 4' 28W SKS2GPK228 SKS2GPK328 2' x 4' 2-T5 3-T5 28W SKA2GPK228 SKA2GPK328 5" (127mm) Example • Door jamb finished black on four sides for positive light stop. • Spring loaded rooster head latches. • 18 gauge steel hinges. • Construction to meet NYC Code Requirements or Chicago Plenum is available. page 4.130 SKS2GPK228 Skyway Triple lens design 24" (610mm) Air handling or static • True mitered corner aluminum lens frame. 120 Electronic T5 program start PG Electronic T5 28W instant start WA*† Electronic T5 28W bi-level step ballast (2 lamp) VY DALI Ballast DA * Ballast (WA) only available in 120 or 277 volt. 56 Input watts 0.93 B.F. DALI = digital addressable dimming Drywall kit: Conversion kit for 2' x 4' unit: FK92X4. Emergency/wiring options: For special wiring, fusing, electronic dimming ballasts, consult factory. Fusing: Suffix: A (Internal fast-blow fusing). Suffix: C (Internal slow-blow fusing). 4.30 Philips Lightolier 5" (127mm) Voltage 120 = 120V 277 = 277V UNV= 120-277V SKS2GPK254UNVPG WA 30˚ Ballast See page 4.30 A Options See page 4.30 and page 4.130 Candlepower Curve Reference data 5" (127mm) Ballast type <10THD † 1950 Catalog no. 24" (610mm) • Built-in earthquake clips. Options & accessories Lamp watts 2-T5 3-T5 • Eyeleted heat removal vents in fixture ends. • Hemmed over side rails for maximum safety. 60˚ Input watts (120V) 54.5W Ballast factor 0.93 24" (610mm) Efficiency 72.7% Spacing ratio 1.3 Electronic ballast 950 60˚ Input watts (120V) 114.9W Ballast factor 1.0 24" (610mm) 1900 Ordering information Type Size Lamp qty –type Static 2' x 4' 2-T5HO 3-T5HO Air handling 2' x 4' 2-T5HO 3-T5HO Example SKS2GPK254 Skyway Triple lens design Air handling or static Lamp watts 54W 54W SKA2GPK254 SKA2GPK354 UNV PG Voltage 120 = 120V 277 = 277V UNV= 120-277V 2850 Catalog no. SKS2GPK254 SKS2GPK354 Ballast See page 4.30 30˚ A Options See page 4.30 and page 4.130 For complete specification information visit www.lightolier.com Professional – Linear recessed and surface lighting Skyway T5 2' x 2' Premium specification recessed air handling or static luminaires Skyway’s aesthetically pleasing triple lens design features a clear conical prismatic center lens, enhanced by softly curved frost white acrylic lenses on each side, mounted in a regressed extruded aluminum frame with spring loaded latches. These 85% light transmission lenses, coupled with an internal reflector system coated with our 95% reflective white paint, creates our new, energy efficient Skyway. SKS2GPK2FTUNVIB Candlepower Curve Reference data 5" (127mm) Efficiency 76.5% Spacing ratio 1.4 Electronic ballast 700 60˚ • 76.5% efficient two lamp 40W Twin tube T5 2' x 2' luminaire. Ordering information Size Static Air handling Example Lamp qty –type Lamp watts 2' x 2' 2-Twin tube T5 40W SKS2GPK2FT 2' x 2' 2-Twin tube T5 40W5" SKA2GPK2FT SKS2GPK2FT 24" (610mm) Skyway Triple lens design Air handling or static 24" (610mm) (127mm) UNV 2100 Catalog no. IB 5" Voltage (127mm) Ballast 120 = 120V See page 4.31 277 = 277V UNV= 120-277V • Clear acrylic conical prismatic center lens. • Internal reflector coated with 95% reflective white paint. 1400 Type • Aesthetically pleasing triple lens design. • Curved high light transmission frost white acrylic side lenses. Input watts (120V) 69.1W Ballast factor 0.88 24" (610mm) Features 30˚ • 72.8% efficient two lamp 14W T5 2' x 2' luminaire. • 74.6% efficient two lamp 24W T5HO 2' x 2' luminaire. • 5" deep body. • Black housing exterior for cooler ballast operating temperature. • Eyeleted heat removal vents in fixture ends. A • Hemmed over side rails for maximum safety. Options See page 4.31 and page 4.130 • Fixture ends turned-in for safe handling. • Built-in earthquake clips. • Door jamb finished black on four sides for positive light stop. • True mitered corner aluminum lens frame. • Spring loaded rooster head latches. • 18 gauge steel hinges. SKS2GPK224UNVPG Candlepower Curve Reference data 5" (127mm) Efficiency 74.6% Spacing ratio 1.3 Electronic ballast Options & accessories 400 Ballast type <10THD <20THD 800 Ordering information Type Size Lamp qty –type Static 2' x 2' 2-T5 2-T5HO 3-T5HO Air handling 2' x 2' 2-T5 2-T5HO 3-T5HO Example SKS2GPK224 Skyway Triple lens design Air handling or static Lamp watts 1200 Catalog no. page 4.130 60˚ Input watts (120V) 51.3W Ballast factor 1.0 24" (610mm) • Construction to meet NYC Code Requirements or Chicago Plenum is available. 30˚ Electronic T5 program start PG – Electronic TT5 40W PR* – Electronic TT5 40W IB SB Electronic TT5 50W BP – 14W 24W 24W SKS2GPK214 SKS2GPK224 SKS2GPK324 Electronic TT5 55W BF – 14W 24W 24W SKA2GPK214 SKA2GPK224 SKA2GPK324 DALI Ballast UNV Voltage 120 = 120V 277 = 277V UNV= 120-277V PG Ballast See page 4.31 Electronic T5 14W bi-level VY – step ballast (2 lamp) DA – * Program start. DALI = digital addressable dimming A Options See page 4.31 and page 4.130 Drywall kit: Conversion kit for 2' x 2' unit: FK92X2. Emergency/wiring options: For special wiring, fusing, electronic dimming ballasts, consult factory. Fusing: Suffix: A (Internal fast-blow fusing). Suffix: C (Internal slow-blow fusing). Comprehensive lighting catalog 7th Edition 4.31 Linear recessed and surface lighting – Professional Skyway T5 1' x 4' Premium specification recessed air handling or static luminaires Skyway’s aesthetically pleasing triple lens design features a clear conical prismatic center lens, enhanced by softly curved frost white acrylic lenses on each side, mounted in a regressed extruded aluminum frame with spring loaded latches. These 85% light transmission lenses, coupled with an internal reflector system coated with our 95% reflective white paint, creates our new, energy efficient Skyway. SKS1GPK228UNVPG Features • Aesthetically pleasing triple lens design. • Curved high light transmission frost white acrylic side lenses. Reference data Candlepower Curve Efficiency 64.7% Spacing ratio 1.2 4" (102mm) • Clear acrylic conical prismatic center lens. Electronic ballast • Internal reflector coated with 95% reflective white paint. Input watts (120V) 59.0W Ballast factor 1 11⅞" (302mm) 550 1100 • 64.7% efficient two lamp 28W T5 1' x 4' luminaire. • 4" deep body. 4" (102mm) • Black housing exterior for cooler ballast operating temperature. • Eyeleted heat removal vents in fixture ends. • Hemmed over side rails for maximum safety. Ordering information • Built-in earthquake clips. Type • True mitered corner aluminum lens frame. Size Static 1' x 4' Air handling 1' x 4' 1-T5 2-T5 1-T5HO 2-T5HO • 18 gauge steel hinges. Options & accessories Lamp qty –type 1-T5 2-T5 1-T5HO 2-T5HO • Spring loaded rooster head latches. • Construction to meet NYC Code Requirements or Chicago Plenum is available. 1650 30˚ 11⅞" (302mm) • Fixture ends turned-in for safe handling. • Door jamb finished black on four sides for positive light stop. 60˚ Lamp watts Catalog no. 28W 28W 54W 54W SKS1GPK128 SKS1GPK228 SKS1GPK154 SKS1GPK254 28W 28W 54W 54W SKA1GPK128 SKA1GPK228 SKA1GPK154 SKA1GPK254 page 4.130 Ballast type <10THD Electronic T5 program start PG Electronic T5 28W instant start WA*† Electronic T5 28W bi-level step ballast (2 lamp) VY DALI Ballast DA Example SKS1GPK228 Skyway Triple lens design Air handling or static UNV PG Voltage 120 = 120V 277 = 277V UNV= 120-277V Ballast See page 4.32 A Options See page 4.32 and page 4.130 * Ballast (WA) only available in 120 or 277 volt. † 56 Input watts 0.93 B.F. DALI = digital addressable dimming Drywall kit: Conversion kit for 1' x 4' unit: FK91X4. Emergency/wiring options: For special wiring, fusing, electronic dimming ballasts, consult factory. Fusing: Suffix: A (Internal fast-blow fusing). Suffix: C (Internal slow-blow fusing). 4.32 Philips Lightolier For complete specification information visit www.lightolier.com Professional – Linear recessed and surface lighting Skyway T8 2' x 4' Premium specification recessed air handling or static luminaires Skyway’s aesthetically pleasing triple lens design features a clear conical prismatic center lens, enhanced by softly curved frost white acrylic lenses on each side, mounted in a regressed extruded aluminum frame with spring loaded latches. These 85% light transmission lenses, coupled with an internal reflector system coated with our 95% reflective white paint, creates our new, energy efficient Skyway. SKS2GPK232UNVC5 Candlepower Curve Reference data 5" (127mm) Efficiency 75.3% Spacing ratio 1.3 Electronic ballast • Aesthetically pleasing triple lens design. • Curved high light transmission frost white acrylic side lenses. 700 60˚ Input watts (120V) 51.9W Ballast factor 0.77 24" (610mm) Features • Clear acrylic conical prismatic center lens. • Internal reflector coated with 95% reflective white paint. 1400 • 75.3% efficient two lamp 32W T8 2' x 4' luminaire. • 75.4% efficient three lamp 32W T8 2' x 4' luminaire. Ordering information Lamp qty –type Static 2' x 4' 2-T8 32W SKS2GPK232 Air handling 2' x 4' 2-T8 32W5" • Black housing exterior for cooler ballast operating temperature. SKA2GPK232 • Eyeleted heat removal vents in fixture ends. SKS2GPK232 24" (610mm) Skyway 24" (610mm) Triple lens design Air handling or static (127mm) UNV 5" (127mm) Voltage 120 = 120V 277 = 277V UNV= 120-277V Catalog no. • 5" deep body. Size Example Lamp watts 2100 Type 30˚ • Hemmed over side rails for maximum safety. C5 Ballast See page 4.33 • Fixture ends turned-in for safe handling. A • Built-in earthquake clips. Options See page 4.33 and page 4.130 • Door jamb finished black on four sides for positive light stop. • True mitered corner aluminum lens frame. • Spring loaded rooster head latches. • 18 gauge steel hinges. SKS2GPK332UNVH3 Candlepower Curve Reference data 5" (127mm) Efficiency 75.4% Spacing ratio 1.3 Electronic ballast Options & accessories 1050 60˚ Input watts (120V) 87W Ballast factor 0.88 24" (610mm) 2100 Size Static 2' x 4' 3-T8 32W SKS2GPK332 Air handling 2' x 4' 3-T8 32W SKA2GPK332 Example Lamp qty –type SKS2GPK332 Skyway Triple lens design Air handling or static Lamp watts UNV Voltage 120 = 120V 277 = 277V UNV= 120-277V 3150 Catalog no. H3 Ballast See page 4.33 A Options See page 4.33 and page 4.130 page 4.130 Ballast: Specify voltage (120, 277 or UNV) and type and add as suffix, e.g. UNVHI. Ballast type <10THD <20THD Ordering information Type • Construction to meet NYC Code Requirements or Chicago Plenum is available. 30˚ Electronic T8 HI, P2** SO* 1 - 3 Lamp T8 H3*, P3** O3* Electronic T5 PG – Advance Optanium low watt.77 Electronic T8 C5* – * Instant start. ** Program start. Drywall kit: Conversion kit for 2' x 4' unit: FK92X4. Emergency/wiring options: For special wiring, fusing, electronic dimming ballasts, consult factory. Packaging: Individual carton is standard. Fusing: Suffix: A (Internal fast-blow fusing). Suffix: C (Internal slow-blow fusing). Comprehensive lighting catalog 7th Edition 4.33 Linear recessed and surface lighting – Professional Skyway T8 2' x 2' Premium specification recessed air handling or static luminaires Skyway’s aesthetically pleasing triple lens design features a clear conical prismatic center lens, enhanced by softly curved frost white acrylic lenses on each side, mounted in a regressed extruded aluminum frame with spring loaded latches. These 85% light transmission lenses, coupled with an internal reflector system coated with our 95% reflective white paint, creates our new, energy efficient Skyway. SKS2GPK217UNVHI Features • Aesthetically pleasing triple lens design. Candlepower Curve Reference data • Curved high light transmission frost white acrylic side lenses. 5" (127mm) Efficiency 70.7% Spacing ratio 1.3 Electronic ballast • Clear acrylic conical prismatic center lens. • Internal reflector coated with 95% reflective white paint. • 70.7% efficient two Lamp 17W T8 2' x 2' luminaire. • 72.9% efficient three Lamp 17W T8 2' x 2' luminaire. • 5" deep body. • Black housing exterior for cooler ballast operating temperature. Type Size Static 2' x 2' 2-T8 17W SKS2GPK217 Air handling 2' x 2' 2-T8 17W SKA2GPK217 Lamp qty –type SKS2GPK217 Example • Fixture ends turned-in for safe handling. 24" (610mm) Skyway 24" (610mm) Triple lens design Air handling or static • Built-in earthquake clips. • Door jamb finished black on four sides for positive light stop. 60˚ 600 Ordering information Lamp watts • Eyeleted heat removal vents in fixture ends. • Hemmed over side rails for maximum safety. 300 Input watts (120V) 31.7W Ballast factor 0.83 24" (610mm) UNV 5" (127mm) 5" (127mm) Voltage 120 = 120V 277 = 277V UNV= 120-277V Catalog no. HI Ballast See page 4.34 900 30˚ A Options See page 4.34 and page 4.130 • True mitered corner aluminum lens frame. • Spring loaded rooster head latches. SKS2GPK317UNVH3 • 18 gauge steel hinges. Options & accessories 5" (127mm) page 4.130 Efficiency 72.9% Spacing ratio 1.1 Electronic ballast Ballast: Specify voltage (120, 277 or UNV) and type and add as suffix, e.g. UNVHI. Ballast type <10THD <20THD Electronic T8 HI*, P2** SO* 1 - 3 Lamp T8 H3*, P3** O3* * Instant start. ** Program start. Drywall kit: Conversion kit for 2' x 2' unit: FK92X2. Emergency/wiring options: For special wiring, fusing, electronic dimming ballasts, consult factory. Packaging: Individual carton is standard. Candlepower Curve Reference data • Construction to meet NYC Code Requirements or Chicago Plenum is available. 500 1000 Ordering information Type Size Static 2' x 2' 3-T8 17W SKS2GPK317 Air handling 2' x 2' 3-T8 17W SKA2GPK317 Example 60˚ Input watts (120V) 46.6W Ballast factor 1.0 24" (610mm) Lamp qty –type SKS2GPK317 Skyway Triple lens design Air handling or static Lamp watts UNV Catalog no. H3 Voltage 120 = 120V 277 = 277V UNV= 120-277V Ballast See page 4.34 1500 30˚ A Options See page 4.34 and page 4.130 Fusing: Suffix: A (Internal fast-blow fusing). Suffix: C (Internal slow-blow fusing). 4.34 Philips Lightolier For complete specification information visit www.lightolier.com Professional – Linear recessed and surface lighting Skyway T8 1' x 4' Premium specification recessed air handling or static luminaires Skyway’s aesthetically pleasing triple lens design features a clear conical prismatic center lens, enhanced by softly curved frost white acrylic lenses on each side, mounted in a regressed extruded aluminum frame with spring loaded latches. These 85% light transmission lenses, coupled with an internal reflector system coated with our 95% reflective white paint, creates our new, energy efficient Skyway. SKS1GPK232UNVHI Candlepower Curve Reference data Efficiency 66.4% Spacing ratio 1.2 4" (102mm) Electronic ballast • Aesthetically pleasing triple lens design. • Curved high light transmission frost white acrylic side lenses. 700 60˚ Input watts (120V) 49.6W Ballast factor 0.77 11 ⅞" (302mm) Features • Clear acrylic conical prismatic center lens. • Internal reflector coated with 95% reflective white paint. 1400 • 66.4% efficient two lamp 32W T8 1' x 4' luminaire. • 4" deep body. 4" (102mm) 2100 30˚ • Black housing exterior for cooler ballast operating temperature. • Eyeleted heat removal vents in fixture ends. • Hemmed over side rails for maximum safety. 11 ⅞" (302mm) • Fixture ends turned-in for safe handling. • Built-in earthquake clips. Ordering information Type Size Static 1' x 4' 1-T8 2-T8 1' x 4' 1-T8 2-T8 Air handling Example Lamp qty –type SKS1GPK232 Skyway Triple lens design Air handling or static Lamp watts • Door jamb finished black on four sides for positive light stop. Catalog no. 32W SKS1GPK132 SKS1GPK232 • True mitered corner aluminum lens frame. 32W SKA1GPK132 SKA1GPK232 • 18 gauge steel hinges. UNV Voltage 120 = 120V 277 = 277V UNV= 120-277V HI Ballast See page 4.35 • Spring loaded rooster head latches. • Construction to meet NYC Code Requirements or Chicago Plenum is available. A Options See page 4.35 and page 4.130 Options & accessories page 4.130 Ballast type <10THD <20THD Electronic T8 (1 or 2 lamp) HI* SO* Electronic T8 (1 or 2 lamp) P2** – LOL Dimming T8 PS – Electronic T8 32W bi-level step ballast (2 lamp) V2 – DALI Ballast DA – * Instant start. Standard ** Program start. DALI = digital addressable dimming Other dimming options consult factory. Note: For T8 UNV, you must use HI Ballast Code. Drywall kit: Conversion kit for 1' x 4' unit: FK91X4. Electrical wiring options: Consult factory. For motion or light sensor see folio OA20-10. Fusing: Suffix: A (Internal fast-blow fusing). Suffix: C (Internal slow-blow fusing). Comprehensive lighting catalog 7th Edition 4.35 Linear recessed and surface lighting – Professional Aletta louver shield T8 & T5 2' x 4' & 2' x 2' Direct/indirect recessed static luminaires This family of recessed luminaires features a gently concaved diffuser that provides balanced luminosity, combined with distinctive and elegant architectural detailing. ALS2GUL232UNVHI Features ALS2GUL228UNVPG • 66.2% efficient two lamp 32W T8 2' x 4' luminaire. 5 ⅜" (137mm) • 68.6% efficient two lamp 28W T5 2' x 4' luminaire. 5 ⅜" (137mm) • 63.7% efficient two lamp 17W T8 2' x 2' luminaire. • 62.1% efficient two lamp 24W T5HO 2' x 2' luminaire. 24" (610mm) 24" (610mm) • Housing is black baked polyester enamel die-formed Reference data code gauge cold rolled steel. 20 gauge available for NYC. • The lens assembly is made from extruded 100% DR Frost acrylic. Spring latch lens hinges, left and right sides independently, downward into the room cavity. • The center panel louver is high purity Semi-Specular, 2-3/4" (6.99cm) opening x 1-3/8" (3.49cm) deep on 2" (5.08cm) centers with micro-prismatic side overlays. • 95% reflective white powder painted performance kick reflector. • Extruded aluminum trim, painted white, interfaces with ceiling grid or plaster frame (by others). Options & accessories Electronic ballast Efficiency 68.6% Spacing ratio 1.1 1950 Size Electronic T8 HI*, P2** SO* 1 - 3 Lamp T8 H3*, P3** O3* Example 2' x 4' ** Program start. UNV Options See page 4.36 and page 4.130 5 ⅜" (137mm) ALS2GUL224UNVPG 5 ⅜" (137mm) 24" (610mm) Fusing: Suffix: A (Internal fast-blow fusing). Suffix: C (Internal slow-blow fusing). Reference data Aletta is a unique soft lighting coffer Electronic ballast 24" (610mm) Candlepower Curve Efficiency 62.1% Spacing ratio 1.1 60˚ 450 Electronic ballast Input watts (120V) 31.4W Ballast factor 0.93 Static Example Size 2' x 2' 60˚ 600 Input watts (120V) 47.7W Ballast factor 1.0 Ordering information Type Candlepower Curve Reference data Efficiency 63.7% Spacing ratio 1.2 900 Philips Lightolier A 5 ⅜" (137mm) Packaging: Individual carton is standard. 4.36 HI 24" (610mm) ALS2GUL217UNVHI Emergency/wiring options: For special wiring, fusing, electronic dimming ballasts, consult factory. Whether used in office, conference, classroom or public areas, Aletta is truly easy on the eyes: comfortable lighting to see by and beautiful lighting to look at. Catalog no. Voltage Ballast 120 = 120V See page 4.36 277 = 277V UNV= 120-277V Drywall kit: C onversion kit for 2' x 4' unit: FK92X4. Conversion kit for 2' x 2' unit: FK92X2. 2X2 30˚ ALS2GUL232 ALS2GUL332 ALS2GUL228 ALS2GUL328 ALS2GUL254 ALS2GUL154 32W 32W 28W 28W 54W 54W ALS2GUL232 5 ⅜" (137mm) 60˚ 900 Input watts (120V) 61.6W Ballast factor 1.03 24" (610mm) 1800 Lamp watts 2-T8 3-T8 2-T5 3-T5 2-T5HO 1-T5HO Aletta Direct/indirect recessed Static panel w/elongated lens Electronic T5 PG – * Instant start. Electronic ballast 30˚ Lamp qty –type Ballast: Specify voltage (120, 277 or UNV) and type and add as suffix, e.g. UNVHI. Ballast type <10THD <20THD 60˚ 975 Ordering information Type Candlepower Curve Reference data Input watts (120V) 59.0W Ballast factor 0.88 Static page 4.130 Candlepower Curve Efficiency 66.2% Spacing ratio 1.2 Lamp qty –type 2-T5 3-T5 2-T8 3-T8 2-T5HO 3-T5HO ALS2GUL224 Aletta Direct/indirect recessed Static panel w/elongated lens 1200 30˚ Lamp watts 30˚ Catalog no. ALS2GUL214 ALS2GUL314 ALS2GUL217 ALS2GUL317 ALS2GUL224 ALS2GUL324 14W 14W 17W 17W 24W 24W UNV PG Voltage Ballast 120 = 120V See page 4.36 277 = 277V UNV= 120-277V A Options See page 4.36 and page 4.130 For complete specification information visit www.lightolier.com Professional – Linear recessed and surface lighting Aletta panel shield T8 & T5 2' x 4' & 2' x 2' Direct/indirect recessed static luminaires This family of recessed luminaires features a gently concaved diffuser that provides balanced luminosity, combined with distinctive and elegant architectural detailing. ALS2GUP232UNVHI ALS2GUP228UNVPG Features 5 ⅜" (137mm) 5 ⅜" (137mm) • 69.8% efficient two lamp 32W T8 2' x 4' luminaire. • 73.6% efficient two lamp 28WT5 2' x 4' luminaire. • 68.4% efficient two lamp 17W T8 2' x 2' luminaire. 24" (610mm) Candlepower Curve Reference data Efficiency 69.8% Spacing ratio 1.3 Electronic ballast • 66.8% efficient two lamp 24W T5HO 2' x 2' luminaire. 24" (610mm) Candlepower Curve Reference data Efficiency 73.6% Spacing ratio 1.3 60˚ 825 Input watts (120V) 59.0W Ballast factor 0.88 1650 Electronic ballast 5 ⅜" (137mm) 60˚ 750 Input watts (120V) 61.7W Ballast factor 1.0 24" (610mm) 1500 30˚ Static Example Size Lamp qty –type Lamp watts 2-T8 3-T8 2-T5 3-T5 2-T5HO 1-T5HO 2' x 4' 32W 32W 28W 28W 54W 54W ALS2GUP232 UNV Aletta Direct/indirect recessed Static panel w/elongated lens 30˚ • 95% reflective white powder painted performance kick reflector. Catalog no. • Extruded aluminum trim, painted white, interfaces with ceiling grid or plaster frame (by others). ALS2GUP232 ALS2GUP332 ALS2GUP228 ALS2GUP328 ALS2GUP254 ALS2GUP154 Options & accessories HI Ballast type <10THD <20THD A Options See page 4.37 and page 4.130 5 ⅜" (137mm) 5 ⅜" (137mm) Efficiency 68.4% Spacing ratio 1.1 Electronic ballast Candlepower Curve Efficiency 66.8% Spacing ratio 1.1 60˚ 450 Input watts (120V) 31.2W Ballast factor 0.93 Electronic ballast O3* Drywall kit: C onversion kit for 2' x 4' unit: FK92X4. Conversion kit for 2' x 2' unit: FK92X2. Emergency/wiring options: For special wiring, fusing, electronic dimming ballasts, consult factory. Packaging: Individual carton is standard. 24" (610mm) Reference data SO* H3*, P3** ** Program start. ALS2GUP224UNVPG Candlepower Curve HI*, P2** 1 - 3 Lamp T8 * Instant start. 5 ⅜" (137mm) Reference data Electronic T8 Electronic T5 PG – 24" (610mm) 24" (610mm) page 4.130 Ballast: Specify voltage (120, 277 or UNV) and type and add as suffix, e.g. UNVHI. Voltage Ballast 120 = 120V See page 4.37 277 = 277V UNV= 120-277V ALS2GUP217UNVHI • The lens assembly is made from extruded 100% DR Frost acrylic. Spring latch lens hinges, left and right sides independently, downward into the room cavity. • Center Panel is constructed with 24 gauge powder painted CRS with linear micro-prismatic lens overlays. Elongated lens openings are 21-1/2" (54.61cm) windows. Ordering information Type • Housing is black baked polyester enamel die-formed code gauge cold rolled steel. 20 gauge available for NYC. 60˚ 525 Fusing: Suffix: A (Internal fast-blow fusing). Suffix: C (Internal slow-blow fusing). Aletta is a unique soft lighting coffer Input watts (120V) 47.5W Ballast factor 1.0 900 1050 30˚ 30˚ Ordering information Type Static Example Size 2' x 2' Lamp qty –type 2-T5 3-T5 2-T8 3-T8 2-T5HO 3-T5HO ALS2GUP217 Aletta Direct/indirect recessed Static panel w/elongated lens Lamp watts 14W 14W 17W 17W 24W 24W UNV Catalog no. ALS2GUP214 ALS2GUP314 ALS2GUP217 ALS2GUP317 ALS2GUP224 ALS2GUP324 HI Voltage Ballast 120 = 120V See page 4.37 277 = 277V UNV= 120-277V 2X2 A Options See page 4.37 and page 4.130 Whether used in office, conference, classroom or public areas, Aletta is truly easy on the eyes: comfortable lighting to see by and beautiful lighting to look at. Comprehensive lighting catalog 7th Edition 4.37 Linear recessed and surface lighting – Professional Alter high efficiency 2' x 4' Direct/indirect recessed static luminaires With its balanced brightness and high-lumen package capable of accommodating up to 3 linear T8, T5 or 4 TT5 lamps, the Alter High Efficiency 2' x 4' delivers superior luminous efficacy that is perfect for wide open spaces, including workplaces with no or low partitions. This common-dimension luminaire is optically designed to create cost-effective specificationready soft lighting for popular ceiling grids. QHE2GPFOP232UNVHI Features 2' x 4' Microperforated mesh lamp shields, 2-lamp 32W T8 • Alter soft white film on inside of microperforated Mesh Lamp Shields conceal lamp image providing balance between reflected and direct light. 5½" (140mm) Efficiency 70.3% Spacing ratio 1.3 Electronic ballast • Seamless welded form: curved top and side reflectors are formed together without any gaps or visual barriers. 23 1316" (605mm) • 95% reflective Alter soft white paint finish and specular interior reflector. • 5 ½" deep one-piece body for easy installation. 47 1316" (1214mm) • Easy access to ballast through lamp compartment. QHE2GPFOP332UNVH3 • Fits standard T-grid, exposed slot T-grid and drywall ceilings. 74 57 45 36 29 1378 1500 40W TT5 PB 50W TT5 BP T5 PF T8 HI T8 PS 3 LPB T8 H3 T5 PG 24" (610mm) 47 " (1214mm) 13 16 QHE2GPFOP228UNVPG Candlepower Curve 700 RCR C.U. 1 3 5 7 9 67 52 41 33 27 1916 2100 Candlepower Curve Efficiency 75.7% Spacing ratio 1.3 Electronic ballast 23 1316" (605mm) Hold down clips: Standard T 15/16" only: QVS-HD. Fusing: Suffix: A (Internal fast-blow fusing). Suffix: C (Internal slow-blow fusing). 47 1316" (1214mm) Ordering information Static Example 2' x 4' Lamp qty –type 2-T5 2-T5HO 3-T5 3-T5HO 2-T8 3-T8 4-TT5 QHE2GPFOP232 Alter High Efficiency Direct/indirect recessed w/microperforated mesh lamp shields 500 60˚ Input watts (120V) 65.0W Ballast factor 0.88 Emergency/wiring options: For special wiring, fusing, electronic dimming ballasts, consult factory. Size 30˚ 2' x 4' Microperforated mesh lamp shields, 2-lamp 28W T5 5½" (140mm) LPB = Number of lamps per ballast. Type 60˚ 1400 Reference data Drywall kit: Conversion kit for 2' x 4' unit: FK92X4. 30˚ Input watts (120V) 85.0W Ballast factor 0.88 PowerSpec HDF dimming IB Philips Lightolier 1 3 5 7 9 1000 Efficiency 64.3% Spacing ratio 1.3 Ballast type 4.38 C.U. Electronic ballast page 4.72 + 4.130 40W TT5 60˚ 2' x 4' Microperforated mesh lamp shields, 3-lamp 32W T8 5½" (140mm) Ballast: Specify voltage (120, 277 or UNV) and type and add as suffix, e.g. UNVHI. Electronic RCR Reference data • Luminaire can be row mounted Options & accessories 500 Input watts (120V) 62.0W Ballast factor 0.88 • No visible welding, screws, latches, springs, hooks, rivets or plastic supports. • Swing-down microperforated lamp shields for easy relamping. Candlepower Curve Reference data • 75.7% efficient two lamp 28W T5 2' x 4' luminaire. Lamp watts RCR C.U. 1 3 5 7 9 79 61 48 38 31 1000 1311 1500 30˚ Catalog no. 28W 54W 28W 54W 32W 32W 40, 50, 55W QHE2GPFOP228 QHE2GPFOP254 QHE2GPFOP328 QHE2GPFOP354 QHE2GPFOP232 QHE2GPFOP332 QHE2GPFOP4FT UNV HI Voltage Ballast Options 120 = 120V See page 4.38 See page 4.38 277 = 277V and page 4.72 UNV= 120-277V For complete specification information visit www.lightolier.com Professional – Linear recessed and surface lighting Alter high efficiency 2' x 2' Direct/indirect recessed static luminaires The compact architectural styling of Alter High Efficiency 2' x 2' provides shadowless balanced brightness combined with increased light efficacy in keeping with specification requirements. Designed for popular 2' x 2' grids, this luminaire allows more flexible, more symmetrical luminaire arrangements. It is suited to most environments, especially private offices where wide distribution, uniformly lit walls and low power densities are important considerations. QHE2GPFOP2FTUNVIB 2' x 2' Microperforated mesh lamp shields, 2-lamp 40W TT5 Candlepower Curve Reference data 5½" (140mm) Efficiency 66.3% Spacing ratio 1.3 Electronic ballast 23 1316" (605mm) 23 1316" (605mm) QHE2GPFOP217UNVHI RCR C.U. 1 3 5 7 9 70 54 44 35 26 RCR C.U. 1 3 5 7 9 68 53 41 33 27 500 606 750 Candlepower Curve Ordering information Static Example 2' x 2' QHE2GPFOP232 Alter High Efficiency Direct/indirect recessed w/microperforated mesh lamp shields Lamp watts Options & accessories page 4.72 + 4.130 Ballast: Specify voltage (120, 277 or UNV) and type and add as suffix, e.g. UNVHI. Ballast type PowerSpec HDF dimming 40W TT5 IB 40W TT5 PB 50W TT5 BP T5 PF 55W TT5 BF PS T8 HI 3 LPB T8 H3 T5 PG T8 LPB = Number of lamps per ballast. Drywall kit: Conversion kit for 2' x 2' unit: FK92X2. Hold down clips: Standard T 15/16" only: QVS-HD. 300 60˚ Input watts (120V) 51.0W Ballast factor 0.88 23 1316" (605mm) 1-TT5 2-TT5 2-T8 3-T8 2-T5HO 3-T5HO 30˚ Efficiency 68.6% Spacing ratio 1.3 Electronic ballast 23 1316" (605mm) • Swing-down lamp shield for easy relamping. Electronic Reference data Lamp qty –type 60˚ 250 2' x 2' Microperforated mesh lamp shields, 2-lamp 24W T5 5½" (140mm) • 5 ½" deep, one-piece body for easy installation. • Luminaire can be row mounted Input watts (120V) 74.0W Ballast factor 0.88 QHE2GPFOP224UNVPG • Seamless welded form: curved top and side reflectors are formed together without any gaps or visual barriers. • Easy access to ballast through lamp compartment. Efficiency 64.9% Spacing ratio 1.3 23 1316" (605mm) Size 30˚ Candlepower Curve Electronic ballast 23 1316" (605mm) • Alter soft white film on inside of microperforated Mesh Lamp Shields conceal lamp and provides a balance between reflected and direct light. • 95% reflective Alter soft white paint finish. 1444 1500 2' x 2' Microperforated mesh lamp shields, 2-lamp 17W T8 5½" (140mm) • 69% efficient two lamp 24W T5HO 2' x 2' luminaire. • No visible welding, screws, latches, springs, hooks, rivets or plastic supports. 1000 Reference data Type 60˚ 500 Input watts (120V) 65.2W Ballast factor 0.88 Features RCR C.U. 1 3 5 7 9 72 56 44 35 28 Fusing: Suffix: A (Internal fast-blow fusing). Suffix: C (Internal slow-blow fusing). 600 820 900 Emergency/wiring options: For special wiring, fusing, electronic dimming ballasts, consult factory. 30˚ Catalog no. 40, 50, 55W QHE2GPFOP1FT 40, 50, 55W QHE2GPFOP2FT 17W QHE2GPFOP217 17W QHE2GPFOP317 24W QHE2GPFOP224 24W QHE2GPFOP324 UNV IB Voltage Ballast 120 = 120V See page 4.39 277 = 277V UNV= 120-277V Options See page 4.39 and page 4.72 Comprehensive lighting catalog 7th Edition 4.39 Linear recessed and surface lighting – Professional Alter high efficiency 1' x 4' Direct/indirect recessed static luminaires The Alter High Efficiency 1' x 4' brings together excellent power-density value, architectural styling and Alter’s characteristic low, balanced brightness glow producing a soft awareness of the lighting element. Its linear appearance suggests movement, making it ideally suited for specification in corridors and circulation areas. QHE1GPFOP232UNVHI Features 1' x 4' Microperforated mesh lamp shields, 2-lamp 32W T8 • Even, shadowless lighting reduces veiling reflections. Efficiency 62.7% Spacing ratio 1.3 5" (127mm) • Alter soft white film on inside of microperforated Mesh Lamp Shields conceal lamp image providing a balance between reflected and direct light. Electronic ballast • Swing-down lamp shields for easy relamping. Easy access to ballast through removable back reflector compartment. 11 1316" (300mm) • No visible welding, screws, latches, springs, hooks, rivets or plastic supports. • Can be row mounted Options & accessories 9 ¾" (248mm) 47 1316" (1214mm) page 4.72 + 4.130 QHE1GPFOP228UNVPG 1 1116" (43mm) RCR C.U. 1 3 5 7 9 66 52 41 33 25 1000 1372 1500 Candlepower Curve Reference data T8 HI T5 PG T8 T5 Efficiency 65.0% Spacing ratio 1.3 5" (127mm) PowerSpec HDF dimming PF Electronic ballast PS 30˚ 1' x 4' Microperforated mesh lamp shields, 2-lamp 28W T5 Ballast type Electronic 60˚ 500 Input watts (120V) 56.5W Ballast factor 0.88 12" (305mm) • 95% reflective Alter soft white paint finish. Ballast: Specify voltage (120, 277 or UNV) and type and add as suffix, e.g. UNVHI. Candlepower Curve Reference data • 65% efficient two lamp 28W T5 1' x 4' luminaire. 500 60˚ Input watts (120V) 65.0W Ballast factor 0.88 12" (305mm) Drywall kit: Conversion kit for 1' x 4' unit: FK91X4. Hold down clips: Standard T 15/16" only: QVS-HD. 11 1316" (300mm) Emergency/wiring options: For special wiring, fusing, electronic dimming ballasts, consult factory. Fusing: Suffix: A (Internal fast-blow fusing). Suffix: C (Internal slow-blow fusing). 9 ¾" (248mm) 47 1316" (1214mm) 1 1116" (43mm) RCR C.U. 1 3 5 7 9 68 54 43 35 27 1000 1375 1500 30˚ Ordering information Type Static Example Size 1' x 4' Lamp qty –type 1-T5 1-T5HO 2-T5 2-T5HO 2-T8 QHE1GPFOP232 Alter High Efficiency Direct/indirect recessed w/microperforated mesh lamp shields 4.40 Philips Lightolier Lamp watts Catalog no. QHE1GPFOP128 QHE1GPFOP154 QHE1GPFOP228 QHE1GPFOP254 QHE1GPFOP232 28W 54W 28W 54W 32W UNV HI Voltage Ballast 120 = 120V See page 4.40 277 = 277V UNV= 120-277V Options See page 4.40 and page 4.72 For complete specification information visit www.lightolier.com Professional – Linear recessed and surface lighting Alter classic 2' x 4' Direct/indirect air handling or static recessed luminaires Functionality with crisp clean lines describes the 2' x 4' Alter luminaire. Using very popular T5, T8 and TT5 lamp technology, it offers the perfect lighting solution for spaces where larger ceiling grids are used. This luminaire provides visual interest, soft balanced brightness and is well suited for larger open spaces. When installed in continuous rows this luminaire can also create a very clean cove-like appearance. Features QVS2GPFOS232UNVHI 2' x 4' Microperforated mesh lamp shields (static), 2-lamp 32W T8 Candlepower Curve Reference data 5½" (140mm) Efficiency 56.9% Spacing ratio 1.3 • Seamless welded form: curved top and side reflectors are formed together without any gaps or visual barriers. Electronic ballast 23 1316" (605mm) QVA2GPFOP232UNVHI RCR C.U. 1 3 5 7 9 60 46 37 29 24 • 5 ½" deep one-piece body for easy installation. 1135 1200 • Easy access to ballast through lamp compartment. • Fits standard T-grid, exposed slot T-grid and drywall ceilings. Candlepower Curve Static Example 2' x 4' 700 RCR C.U. 1 3 5 7 9 52 41 32 26 19 QVS2GPFOS232 Alter Classic Direct/indirect recessed w/microperforated mesh lamp shields Lamp watts Catalog no. 28W 54W 28W 54W 32W 32W 40, 50, 55W QVS2GPFOS228 QVS2GPFOS254 QVS2GPFOS328 QVS2GPFOS354 QVS2GPFOS232 QVS2GPFOS332 QVS2GPFOS4FT UNV HI Voltage Ballast 120 = 120V See page 4.41 277 = 277V UNV= 120-277V Electronic 1751 2100 page 4.72 + 4.130 Ballast: Specify voltage (120, 277 or UNV) and type and add as suffix, e.g. UNVHI. Ballast type 1400 For QVA see below for ordering instructions 2-T5 2-T5HO 3-T5 3-T5HO 2-T8 3-T8 4-TT5 60˚ Input watts (120V) 62.0W Ballast factor 0.88 40" (1016mm) 48" (1120mm) • Luminaire can be row mounted (not applicable with the air handling option) Options & accessories Efficiency 49.2% Spacing ratio 1.4 Electronic ballast Lamp qty –type • Swing-down microperforated lamp shields for easy relamping. • Fully recessed luminaire and lamp compartment. 23 1316" (605mm) Size 30˚ 2' x 4' Microperforated mesh lamp shields (air handling), 2-lamp 32W T8 5⅛" (130mm) Type • No visible welding, screws, latches, springs, hooks, rivets or plastic supports. • 95% reflective Alter soft white paint finish and specular interior reflector. 800 Reference data Ordering information 60˚ 400 Input watts (120V) 62.0W Ballast factor 0.88 47 1316" (1214mm) • Alter soft white film on inside of microperforated Mesh Lamp Shields conceal lamp image providing balance between reflected and direct light. 30˚ PowerSpec HDF dimming 40W TT5 IB 40W TT5 PB 50W TT5 BP T5 PF T8 HI T8 PS 3 LPB T8 H3 Program start T5 PG LPB = Number of lamps per ballast. Drywall kit: Conversion kit for 2' x 4' unit: FK92X4. Hold down clips: Standard T 15/16" only: QVS-HD. Emergency/wiring options: For special wiring, fusing, electronic dimming ballasts, consult factory. Fusing: Suffix: A (Internal fast-blow fusing). Suffix: C (Internal slow-blow fusing). Options See page 4.41 and page 4.72 Clear Acrylic Plate Drop Down Element Clear polished acrylic drop-down visual element with projected color face. Substitute acrylic color suffix in place of open slot only. Suffix: GC (clear) GB (blue) GG (green) GR (red) One-piece lamp shield Air handling Replace OS in the ordering info by OP. OS Static only. Replace QVS in the ordering info by QVA and OS to OP. N/A for 1' x 4'. e.g. QVS2GPFOS (OS = Open Slot) e.g. QVS2GPFGB (GB = Blue Acrylic) For other colors or special orders, consult your Philips Lightolier representative. Comprehensive lighting catalog 7th Edition 4.41 Linear recessed and surface lighting – Professional Alter classic 2' x 2' Direct/indirect air handling or static recessed luminaires Architectural styling combined with visually exciting elements can provide shadowless balanced brightness. Low brightness glow provides the occupant with a soft awareness of the lighting element, while increasing depth perception and sense of orientation within the space. These luminaires offer a good lighting solution for open circulation for a distinctive appearance. Features • Alter soft white film on inside of microperforated Mesh Lamp Shields conceal lamp and provides a balance between reflected and direct light. QVS2GPFOS2FTUNVIB 2' x 2' Microperforated mesh lamp shields (static), 2-lamp 40W TT5 5½" (140mm) • No visible welding. Specular interior reflector with solid lamp shield only. Efficiency 58.5% Spacing ratio 1.3 Electronic ballast 23 1316" (605mm) • 5 ½" deep, one-piece body for easy installation (QVS only). • Swing-down lamp shield for easy relamping. • Easy access to ballast through lamp compartment. • Luminaire can be row mounted (not applicable with the air handling option) Options & accessories 23 1316" (605mm) page 4.72 + 4.130 QVA2GPFOP2FTUNVIB 40W TT5 IB 50W TT5 BP 55W TT5 BF T8 HI 3 LPB T8 H3 Ordering information Type Size Hold down clips: Standard T 15/16" only: QVS-HD. Emergency/wiring options: For special wiring, fusing, electronic dimming ballasts, consult factory. Fusing: Suffix: A (Internal fast-blow fusing). Suffix: C (Internal slow-blow fusing). 61 48 38 30 25 1227 1500 Static Candlepower Curve Example 200 RCR C.U. 1 3 5 7 9 49 38 31 25 18 60˚ 400 590 600 30˚ For QVA see below for ordering instructions Lamp qty –type Lamp watts Catalog no. 40, 50, 55W 40, 50, 55W 17W 17W 24W 24W QVS2GPFOS1FT QVS2GPFOS2FT QVS2GPFOS217 QVS2GPFOS317 QVS2GPFOS224 QVS2GPFOS324 QVS2GPFOS2FT UNV IB Alter Classic Direct/indirect recessed w/microperforated mesh lamp shields Voltage Ballast 120 = 120V See page 4.42 277 = 277V UNV= 120-277V 2' x 2' 30˚ Efficiency 50.8% Spacing ratio 1.4 20" (508mm) 24" (610mm) Program start T5 PG Drywall kit: Conversion kit for 2' x 2' unit: FK92X2. 1 3 5 7 9 1000 Input watts (120V) 74.0W Ballast factor 0.88 24" (610mm) PB LPB = Number of lamps per ballast. C.U. Electronic ballast PowerSpec HDF dimming 40W TT5 RCR Reference data Ballast type 60˚ 2' x 2' Microperforated mesh lamp shields (air handling), 2-lamp 40W TT5 5⅛" (130mm) Electronic 500 Input watts (120V) 74.0W Ballast factor 0.88 • 95% reflective Alter soft white paint finish. Ballast: Specify voltage (120, 277 or UNV) and type and add as suffix, e.g. UNVHI. Candlepower Curve Reference data • Seamless welded form: curved top and side reflectors are formed together without any gaps or visual barriers. 1-TT5 2-TT5 2-T8 3-T8 2-T5HO 3-T5HO Options See page 4.42 and page 4.72 Clear acrylic plate drop down element Clear polished acrylic drop-down visual element with projected color face. Substitute acrylic color suffix in place of open slot only. Suffix: GC (clear) GB (blue) GG (green) GR (red) e.g. QVS2GPFOS (OS = Open Slot) e.g. QVS2GPFGB (GB = Blue Acrylic) For other colors or special orders, consult your Philips Lightolier representative. 4.42 Philips Lightolier One-piece lamp shield Air handling Replace OS in the ordering info by OP. OS Static only. Replace QVS in the ordering info by QVA and OS to OP. N/A for 1' x 4'. For complete specification information visit www.lightolier.com Professional – Linear recessed and surface lighting Alter classic 1' x 4' Direct/indirect static recessed luminaires The Alter 1' x 4' combines architectural styling with visually exciting elements to provide a shadowless balanced brightness. Linear appearance makes this luminaire ideally suited for corridors and circulation areas. QVS1GPFOS232UNVHI 1' x 4' Microperforated mesh lamp shields, 2-lamp 32W T8 Candlepower Curve Reference data Efficiency 50.0% Spacing ratio 1.3 5" (127mm) Electronic ballast 12" (305mm) 60˚ 400 Input watts (120V) 62.0W Ballast factor 0.88 47 1316" (1214mm) QVS1GPFOS2FTUNVIB RCR C.U. 1 3 5 7 9 53 42 33 27 22 30˚ Candlepower Curve 400 60˚ Input watts (120V) 74.0W Ballast factor 0.88 RCR C.U. 1 3 5 7 9 52 41 32 26 19 800 1053 1200 30˚ Static Example Size 1' x 4' page 4.72 + 4.130 Electronic PowerSpec HDF dimming 40W TT5 IB 50W TT5 BP T5 PF 55W TT5 BF T8 PS T8 HI T5 PG 40W TT5 PB Drywall kit: Conversion kit for 1' x 4' unit: FK91X4. Ordering information Type Options & accessories Ballast: Specify voltage (120, 277 or UNV) and type and add as suffix, e.g. UNVHI. Ballast type Electronic ballast 47 " (1214mm) • No visible welding, screws, latches, springs, hooks, rivets or plastic supports. • Can be row mounted Efficiency 47.2% Spacing ratio 1.3 13 16 • Alter soft white film on inside of microperforated Mesh Lamp Shields conceal lamp image providing a balance between reflected and direct light. Not available in air handling. • Swing-down lamp shields for easy relamping. Easy access to ballast through removable back reflector compartment. 1145 1200 Reference data 12" (305mm) • Even, shadowless lighting reduces veiling reflections. • 95% reflective Alter soft white paint finish. 800 1' x 4' Microperforated mesh lamp shields, 2-lamp 40W TT5 5" (127mm) Features Hold down clips: Standard T 15/16" only: QVS-HD. Lamp qty –type 1-T5 1-T5HO 2-T5 2-T5HO 2-T8 2-TT5 QVS1GPFOS232 Alter Classic Direct/indirect recessed w/microperforated mesh lamp shields Lamp watts Cat. no. Exposed T-grid Cat. no. Slot or Concealed T 28W 54W 28W 54W 32W 40, 50, 55W QVS1GPFOS128 QVS1GPFOS154 QVS1GPFOS228 QVS1GPFOS254 QVS1GPFOS232 QVS1GPFOS2FT QVS1TPFOS128 QVS1TPFOS154 QVS1TPFOS228 QVS1TPFOS254 QVS1TPFOS232 QVS1TPFOS2FT UNV HI Voltage Ballast 120 = 120V See page 4.43 277 = 277V UNV= 120-277V Emergency/wiring options: For special wiring, fusing, electronic dimming ballasts, consult factory. Air handling: N/A for 1' x 4' model. Available for Standards, Slot and Concealed. Options See page 4.43 and page 4.72 Clear acrylic plate drop down element Clear polished acrylic drop-down visual element with projected color face. Substitute acrylic color suffix in place of open slot only. One-piece lamp shield Replace OS in the ordering info by OP. Suffix: GC (clear) GB (blue) GG (green) GR (red) e.g. QVS1GPFOS (OS = Open Slot) e.g. QVS1GPFGB (GB = Blue Acrylic) For other colors or special orders, consult your Philips Lightolier representative. Comprehensive lighting catalog 7th Edition 4.43 Linear recessed and surface lighting – Professional Alter classic 20" x 48" & 500mm x 48" Direct/indirect static recessed luminaires 20" x 48" luminaires for 5-foot module ceiling grid (3-part 20" x 60" modules) and metric luminaires. QVS5GPFOS232UNVHI 20" x 48" Microperforated mesh lamp shields 2-lamp 32W T8 Features Candlepower Curve Reference data • Alter soft white film on inside of microperforated Mesh Lamp Shields conceal lamp image providing balance between reflected and direct light. Efficiency 53.4% Spacing ratio 1.4 5 316" (148mm) Electronic ballast • No visible welding, screws, latches, springs, hooks, rivets or plastic supports. 20" (508mm) • Air handling version available. • 95% reflective Alter soft white paint finish and specular interior reflector. 9 ⅞" (251mm) • 5 ½" deep one-piece body for easy installation. • Swing-down microperforated lamp shields for easy relamping. • Fits standard T-grid, exposed slot T-grid and drywall ceilings. • Fully recessed luminaire and lamp compartment. page 4.72 + 4.130 PowerSpec HDF dimming 40W TT5 IB 50W TT5 BP T8 55W TT5 BF T8 HI 3 LPB T8 H3 T5 PG T5 Type Size Static PS Static Emergency/wiring options: For special wiring, fusing, electronic dimming ballasts, consult factory. 1 3 5 7 9 59 49 41 35 30 800 1089 1200 30˚ 500mm x 48" Lamp qty –type Cat. no. Static Cat. no. Air handling* 2-T5 2-T5HO 3-T5 3-T5HO 2-T8 3-T8 Lamp watts 28W 54W 28W 54W 32W 32W QVS5GPFOS228 QVS5GPFOS254 QVS5GPFOS328 QVS5GPFOS354 QVS5GPFOS232 QVS5GPFOS332 QVA5GPFOP228 QVA5GPFOP254 2-T5 2-T5HO 3-T5 3-T5HO 2-T8 3-T8 28W 54W 28W 54W 32W 32W QVS5MPFOS228 QVS5MPFOS254 QVS5MPFOS328 QVS5MPFOS354 QVS5MPFOS232 QVS5MPFOS332 QVA5GPFOP232 * Only luminaires with one piece lamp shield, shown here, are available for air handling. Drywall kit: Conversion kit for 20x40 unit: FK920X4. Filler Plate: Sold separately. For 20" x 60" opening with 20" x 48" luminaire: FPQVS2060. 20" x 48" PF LPB = Number of lamps per ballast. C.U. Ordering information Ballast type Electronic RCR 23 1516" (608mm) 47 1316" (1214mm) • Only luminaires of same size can be row mounted Options & accessories 60˚ 19 1316" (503mm) • Easy access to ballast through lamp compartment. Ballast: Specify voltage (120, 277 or UNV) and type and add as suffix, e.g. UNVHI. 400 Input watts (120V) 56.0W Ballast factor 0.9 Example QVS5GPFOS232 Alter Classic Direct/indirect recessed w/microperforated mesh lamp shields UNV HI Voltage Ballast 120 = 120V See page 4.44 277 = 277V UNV= 120-277V Options See page 4.44 and page 4.72 One-piece lamp shield Replace OS in the ordering info by OP. OS Static only. 4.44 Philips Lightolier For complete specification information visit www.lightolier.com Professional – Linear recessed and surface lighting Alter classic air 2' x 4' & 2' x 2' Direct/indirect recessed luminaires The compact architectural styling of Alter Classic 2' x 2' provides shadowless balanced brightness. Designed for popular 2' x 2' grids, this luminaire allows more flexible, more symmetrical luminaire arrangements. It is suited to most environments, especially private offices where wide distribution and uniformly light walls are important considerations. QVA2GPFOP332UNVH3 2' x 4' Solid lamp shields, 3-lamp 32W T8 Candlepower Curve Reference data 5⅛" (130mm) Efficiency 52.2% Spacing ratio 1.3 Electronic ballast 60˚ 350 Input watts (120V) 84.3W Ballast factor 0.88 24" (610mm) Coefficients of utilization RF 20% RC 80% RW 70 50 30 RCR 40" (1016mm) 700 Features 1050 30˚ • Dual swing down solid lamp shields separated by luminous strip for easy relamping and maintenance. 1 58 56 54 3 49 44 40 5 41 35 30 7 35 28 23 10 27 20 16 48" (1220mm) • Fully recessed luminaire and with two separate lamp compartments. • 95% Reflective Alter soft white paint finish. • Specular interior reflector. QVA2GPFOP2FT120SB 2' x 2' Solid lamp shields, 2-lamp 40W TT5 Candlepower Curve Reference data 5⅛" (130mm) Efficiency 50.8% Spacing ratio 1.3 Input watts (120V) 64.8W Ballast factor 0.88 Coefficients of utilization RF 20% RC 80% RW 70 50 30 RCR 20" (508mm) 24" (610mm) Lamp qty –type Lamp watts 1200 Catalog no. Static Air supply or 2' x 4' Air return 32W 32W 28W 28W 54W 54W 40, 50, 55W QVA2GPFOP232 QVA2GPFOP332 QVA2GPFOP228 QVA2GPFOP328 QVA2GPFOP254 QVA2GPFOP354 QVA2GPFOP4FT Static Air supply or 2' x 2' Air return 1-TT5 2-TT5 2-T8 3-T8 2-T5 3-T5 40, 50W 40, 50W 17W 17W 24W 24W QVA2GPFOP1FT QVA2GPFOP2FT QVA2GPFOP217 QVA2GPFOP317 QVA2GPFOP224 QVA2GPFOP324 Example QVA2GPFOP2FT Alter Classic Air Direct/indirect recessed w/one piece lamp shield 120 • Easy access to ballast through lamp compartment. • Fits standard T-Grid ceilings. Options & accessories page 4.72 + 4.130 Ballast: Specify voltage (120, 277 or UNV) add as suffix, e.g. 120SB. 950 1 56 54 52 3 47 42 39 5 40 34 30 7 34 27 23 10 27 21 16 2-T8 3-T8 2-T5 3-T5 2-T5 3-T5 4-TT5 60˚ 800 Ordering information Size • One piece body for easy installation. • Optional acrylic drop-down visual element. 400 Electronic ballast 24" (610mm) Type • Full-length air slot with right angle stiffener for maximum rigidity and no slot interference. 30˚ Bal. Type <10THD <20THD Electronic PowerSpec HDF Dimming T5 Linear PG – – 40W TT5 IB SB PB BP – 50W TT5 – 55W TT5 BF – – T8 HI SO PS 3 LPB T8 H3 03 – DALI Ballast DA – – LPB = Number of lamps per ballast. DALI = digital addressable dimming Drywall kit: C onversion kit for 2' x 4' unit: FK92X4. Conversion kit for 2' x 2' unit: FK92X2. Emergency/wiring options: For special wiring, fusing, electronic dimming ballasts, consult factory. Fusing: Suffix: A (Internal fast-blow fusing). Suffix: C (Internal slow-blow fusing). SB Voltage Ballast 120 = 120V See page 4.45 277 = 277V UNV= 120-277V Options See page 4.45 and page 4.72 Comprehensive lighting catalog 7th Edition 4.45 Linear recessed and surface lighting – Professional Alter classic wall 9" x 12", 9" x 24" & 9" x 48" Direct/indirect sconce luminaires This simple and clean design can create beautiful slim rows of perforated soft light or add a splash of light in a small space. Two high lumen TT5 Bi-Tube or 2 T8 lamps can provide high illumination levels when used in public spaces. (Luminaire not for through wiring). QVW8SPFOS2FTUNVIB Surface sconce microperforated mesh lamp shields, 2-lamp 40W TT5 Candlepower Curve Reference data 150˚ Efficiency 69.7% Spacing ratio 1.3 4" (102mm) 1200 Electronic ballast 9" (229mm) 120˚ Input watts (120V) 68.4W Ballast factor 0.88 12" (305mm) - 24" (610mm) - 48" (1220mm) 600 RCR C.U. 1 3 5 7 10 60 46 36 29 21 0 228 Ordering information Features • Microperforated Mesh Lamp Shields provide a soft awareness of the light source. Type Size • Alter soft white film on inside of microperforated Mesh Lamp Shields conceal lamp image providing balance between reflected and direct light. Static 9" x 12" 9" x 24" 9" x 48" • 4" deep, meets ADA when wall mounted. • All luminaire surfaces have the same visual appearance. • 95% reflective Alter soft white paint finish. • One-piece body for easy installation. • Swing open lamp shields for easy relamping. • No visible welding, screws, latches, springs, hooks, rivets or plastic supports Options & accessories Example Lamp qty –type 2-TT5 2-TT5 2-T8 QVW8SPFOS2FT Alter Classic Wall Direct/indirect Sconce w/microperforated mesh lamp shields Lamp watts Catalog no. 18W QVW8SPFOS218 40, 50, 55W QVW8SPFOS2FT 32W QVW8SPFOS232 UNV IB Voltage Ballast 120 = 120V See page 4.46 277 = 277V UNV= 120-277V Options See page 4.46 and page 4.72 page 4.72 + 4.130 Ballast: Specify voltage (120, 277 or UNV) and type and add as suffix, e.g. UNVIB. Ballast type Electronic PowerSpec HDF dimming 18W TT5 BA 40W TT5 IB T8 50W TT5 BP 55W TT5 BF T8 HI 40W TT5 PB PS Emergency/wiring options: For special wiring, fusing, electronic dimming ballasts, consult factory. Fusing: Suffix: A (Internal fast-blow fusing). Suffix: C (Internal slow-blow fusing). 4.46 Philips Lightolier For complete specification information visit www.lightolier.com Professional – Linear recessed and surface lighting Alter Wal-Lyter 1' x 2' & 1' x 4' Direct/indirect luminaires This recessed wall washer features smooth-flowing curves and a unique design that incorporates a single lateral lamp and reflector. The result is an asymmetrical light distribution that creates a soft glow and projects additional uniform light onto the wall. Style-matched with Alter full basket design. QVS1GPFAD232UNVHI 1' x 4' Asymmetrical distribution microperforated mesh lamp shields, 2-lamp 32W T8 Candlepower Curve Reference data Efficiency 56.1% 5" (127mm) 400 Input watts (120V) 56.7W Ballast factor 0.88 48" (1220mm) C.U. 1 3 5 7 10 58 44 34 28 21 800 Static 1' x 2' 2-T8 17W 1' x 4' 2-TT5 1-T5 1-T5HO 2-T5 2-T5HO 1-T8 2-T8 40, 50, 55W QVS1GPFAD2FT 28W QVS1GPFAD128 54W QVS1GPFAD154 28W QVS1GPFAD228 54W QVS1GPFAD254 32W QVS1GPFAD132 32W QVS1GPFAD232 Static Example Lamp qty –type QVS1GPFAD232 Alter Wal-Lyter Direct/indirect asymmetrical distribution w/microperforated mesh lamp shields Lamp watts UNV • Asymmetrical optical system provides a soft uniform wall wash 1200 Catalog no. QVS1GPFAD217 page 4.72 + 4.130 Ballast: Specify voltage (120, 277 or UNV) and type and add as suffix, e.g. UNVHI. 1056 Ordering information Size 60˚ Options & accessories RCR Type • Microperforated Mesh Lamp Shields provides soft awareness of the light source. • Swing-down lamp shield for easy relamping. Electronic ballast 12" (305mm) Features 30˚ Ballast type Electronic PowerSpec HDF dimming 40W TT5 IB 50W TT5 BP T5 PF 55W TT5 BF T8 PS T8 HI T5 PG 40W TT5 PB Drywall kit: Conversion kit for 1' x 4' unit: FK91X4. Emergency/wiring options: For special wiring, fusing, electronic dimming ballasts, consult factory. Fusing: Suffix: A (Internal fast-blow fusing). Suffix: C (Internal slow-blow fusing). HI Voltage Ballast 120 = 120V See page 4.47 277 = 277V UNV= 120-277V Options See page 4.47 and page 4.72 Comprehensive lighting catalog 7th Edition 4.47 Linear recessed and surface lighting – Professional Alter louver 2' x 4' & 2' x 2' Direct/indirect recessed static luminaires The Alter Louver luminaire is designed for areas requiring higher light levels. The flat blade perforated louver provides a soft glow shielding. A lens overlay prevents direct view of the lamp source. QVS2GPFLW332UNVH3 2' x 4' Microperforated mesh white lamp shields /white solid blades, 3-lamp 32W T8 Features Candlepower Curve Reference data • Flat blade louver lens overlay lamp shield and perforated curved side lamp shield. 5½" (140mm) • Seamless welded form: curved top and side reflectors are formed together without any gaps or visual barriers. Efficiency 56.7% Spacing ratio 1.5 Electronic ballast 23 1316" (605mm) • No visible welding, screws, latches, springs, hooks, rivets or plastic supports. • 95% reflective Alter soft white paint finish. • 5 ½" deep, one-piece body for easy installation. • Swing-down lamp shield for easy relamping. 47 1316" (1214mm) • Easy access to ballast through lamp compartment. • Fits standard T-grid, exposed slot T-grid ceilings and drywall ceilings (see page 4.218). • Luminaire can be row mounted Options & accessories QVS2GPFLW317UNVH3 5½" (140mm) IB 40W TT5 PB BP T5 PF 55W TT5 BF PS T8 3 LPB 40W TT5 I3 23 " (605mm) HI Ordering information 3 LPB T8 H3 Type Size Program start T5 PG Static Static Example Lamp watts 1 3 5 7 10 59 46 36 29 21 600 782 900 30˚ Catalog no. 2' x 2' 2-TT5 3-TT5 2-T8 3-T8 2-T5HO 3-T5HO 40, 50, 55W QVS2GPFLW2FT 40, 50, 55W QVS2GPFLW3FT 17W QVS2GPFLW217 17W QVS2GPFLW317 24W QVS2GPFLW224 24W QVS2GPFLW324 Alter Louver Direct/indirect recessed w/microperforated mesh lamp shields 60˚ QVS2GPFLW232 QVS2GPFLW332 QVS2GPFLW228 QVS2GPFLW328 QVS2GPFLW254 QVS2GPFLW354 2' x 4' QVS2GPFLW332 300 C.U. 32W 32W 28W 28W 54W 54W Hold down clips: Standard T 15/16" only: QVS-HD. Fusing: Suffix: A (Internal fast-blow fusing). Suffix: C (Internal slow-blow fusing). Lamp qty –type 30˚ Candlepower Curve RCR 2-T8 3-T8 2-T5 3-T5 2-T5HO 3-T5HO LPB = Number of lamps per ballast. Emergency/wiring options: For special wiring, fusing, electronic dimming ballasts, consult factory. 1599 1800 Efficiency 55.4% Spacing ratio 1.4 13 16 T8 Drywall kit: C onversion kit for 2' x 2' unit: FK92X2. Conversion kit for 2' x 4' unit: FK92X4. 60 47 37 29 21 1200 Input watts (120V) 50.1W Ballast factor 0.88 PowerSpec HDF dimming 50W TT5 1 3 5 7 10 Electronic ballast Ballast type 40W TT5 C.U. Reference data 23 1316" (605mm) Electronic RCR 2' x 2' Microperforated mesh white lamp shields/white solid blades, 3-lamp 17W T8 page 4.72 + 4.130 Ballast: Specify voltage (120, 277 or UNV) and type and add as suffix, e.g. UNVHI. 60˚ 600 Input watts (120V) 88.6W Ballast factor 0.88 UNV H3 Voltage Ballast 120 = 120V See page 4.48 277 = 277V UNV= 120-277V Options See page 4.48 and page 4.72 White solid blade 4.48 Philips Lightolier For complete specification information visit www.lightolier.com Professional – Linear recessed and surface lighting Alter louver 1' x 4' Direct/indirect recessed static luminaires The Alter Louver luminaire is designed for areas requiring higher light levels. The flat blade perforated louver provides a soft glow shielding. A lens overlay prevents direct view of the lamp source. QVS1GPFLG232UNVHI 1' x 4' Microperforated mesh white lamp shields/grey solid louver blades, 2-lamp 32W T8 Candlepower Curve Reference data Efficiency 59.8% Spacing ratio 1.2 5" (127mm) • Flat blade louver lens overlay lamp shield and perforated curved side lamp shield. Electronic ballast 48" (1220mm) Ordering information Type Static Example Size 1' x 4' 600 60˚ Input watts (120V) 50.1W Ballast factor 0.88 12" (305mm) Lamp qty –type 2-T8 2-T5 2-T5HO QVS2GPFLV332 Alter Louver Direct/indirect recessed w/microperforated mesh lamp shields Lamp watts 32W 28W 54W UNV RCR C.U. 1 3 5 7 10 64 51 41 33 24 • Seamless welded form: curved top and side reflectors are formed together without any gaps or visual barriers. 1200 • No visible welding, screws, latches, springs, hooks, rivets or plastic supports. 1465 • 95% reflective Alter soft white paint finish. 1800 Catalog no. 30˚ • 5 ½" deep, one-piece body for easy installation. • Swing-down lamp shield for easy relamping. • Easy access to ballast through lamp compartment. • Fits standard T-grid, exposed slot T-grid ceilings and drywall ceilings (see page 4.218). • Luminaire can be row mounted QVS1GPFLW232 QVS1GPFLW228 QVS1GPFLW254 Options & accessories page 4.72 + 4.130 Ballast: Specify voltage (120, 277 or UNV) and type and add as suffix, e.g. UNVHI. H3 Voltage Ballast 120 = 120V See page 4.49 277 = 277V UNV= 120-277V Features Options See page 4.49 and page 4.72 Ballast type Electronic PowerSpec HDF dimming T8 HI T5 PF 3 LPB T8 H3 PS T8 Program start T5 PG LPB = Number of lamps per ballast. Drywall kit: Conversion kit for 1' x 4' unit: FK91X4. Hold down clips: Standard T 15/16" only: QVS-HD. White solid blade Emergency/wiring options: For special wiring, fusing, electronic dimming ballasts, consult factory. Fusing: Suffix: A (Internal fast-blow fusing). Suffix: C (Internal slow-blow fusing). Comprehensive lighting catalog 7th Edition 4.49 Linear recessed and surface lighting – Professional Alter Metalyte 2' x 4' & 2' x 2' Direct/indirect recessed static luminaires Sporting a modern look for modern decors, Alter Metalyte emit surprisingly soft light and a uniform, low-level luminance. Once illuminated the reflector and mesh lamp shields appear bathed in the same uniform brightness. The mixture of direct lighting and backlighting provides a mitigated yet stunning effect. These luminaires blend in particularly well with interiors featuring metallic elements. Features QVS2GPTOS232UNVHI • Seamless semi-specular metallic reflector with lengthwise ridges. • Available one-piece mesh lamp shields with no slot. • Optional drop-down visual element comes in various colors (see page 4.72). • Suited to row mounting for a continuous cove effect Options & accessories 24" (610mm) RCR 5½" (140mm) 1 3 5 7 9 2' x 4' Microperforated mesh lamp shields, 2-lamp 32W T8 C.U. 47 37 29 23 17 page 4.72 + 4.130 Candlepower Curve Reference data Efficiency 44.8% Spacing ratio 1.4 Electronic ballast 400 800 907 Ballast: Specify voltage (120, 277 or UNV) and type and add as suffix, e.g. UNVHI. 1200 48" (1220mm) Ballast type Electronic PowerSpec HDF dimming 40W TT5 IB 40W TT5 PB 50W TT5 BP T8 (32W only) PS 55W TT5 BF IGEN DALI DA T8 HI 3 LPB T8 H3 T5 PG 60˚ Input watts (120V) 57.1W Ballast factor 0.88 QVS2GPTOS332UNVH3 24" (610mm) RCR 5½" (140mm) 1 3 5 7 9 30˚ 2' x 4' Microperforated mesh lamp shields, 3-lamp 32W T8 C.U. 42 33 26 21 19 Candlepower Curve Reference data Efficiency 39.4% Spacing ratio 1.3 Electronic ballast 500 60˚ Input watts (120V) 80.4W Ballast factor 0.88 1000 LPB = Number of lamps per ballast. Drywall kit: C onversion kit for 2' x 4' unit: FK92X4. Conversion kit for 2' x 2' unit: FK92X2. 1273 1500 48" (1220mm) QVS2GPTOS2FTUNVIB 24" (610mm) RCR 5½" (140mm) 1 3 5 7 9 30˚ 2' x 2' Microperforated mesh lamp shields, 2-lamp 40W TT5 C.U. 42 33 26 21 19 Candlepower Curve Reference data Efficiency 39.4% Spacing ratio 1.3 Electronic ballast 400 60˚ Input watts (120V) 80.4W Ballast factor 0.88 800 939 24" (610mm) 1200 Ordering information Type Static* Static* Size Lamp qty –type Lamp watts 4.50 Catalog no. QVS2GPTOS232 QVS2GPTOS332 QVS2GPTOS228 QVS2GPTOS328 QVS2GPTOS254 QVS2GPTOS354 QVS2GPTOS4FT 2' x 4' 2-T8 3-T8 2-T5 3-T5 2-T5HO 3-T5HO 4-TT5 32W 32W 28W 28W 54W 54W 40, 50, 55W 2' x 2' 1-TT5 2-TT5 2-T8 3-T8 2-T5HO 3-T5HO 40, 50, 55W QVS2GPTOS1FT 40, 50, 55W QVS2GPTOS2FT 17W QVS2GPTOS217 17W QVS2GPTOS317 24W QVS2GPTOS224 24W QVS2GPTOS324 * For optional one-piece lamp shield, replace OS by OP. Philips Lightolier 30˚ Example QVS2GPTOS2FT Alter Metalyte Direct/indirect recessed w/mesh lamp shields UNV IB Voltage Ballast Options 120 = 120V See page 4.50 See page 4.50 277 = 277V and page 4.72 UNV= 120-277V For complete specification information visit www.lightolier.com Professional – Linear recessed and surface lighting Alter Metalyte louver 2' x 4' & 2' x 2' Direct/indirect recessed static luminaires Sporting a modern look for modern decors, Alter Metalyte louver emit surprisingly soft light and a uniform, low-level luminance. This luminaire allows up to 3 TT5 lamps for a higher lumen package. Once illuminated the reflector and mesh lamp shield appear bathed in the same uniform brightness. The mixture of direct lighting, backlighting and the choice of louver and blades finishes indeed provides a mitigated yet stunning effect. These luminaires blend in particularly well with interiors featuring metallic elements. Features QVS2GPTLG232UNVHI 24" (610mm) 2' x 4' Microperforated mesh white lamp shields /grey solid louver blades, 2-lamp 32W T8 RCR 5½" (140mm) 1 3 5 7 9 C.U. 43 34 27 21 16 Candlepower Curve Reference data Efficiency 41.1% Spacing ratio 1.4 Electronic ballast 900 24" (610mm) 30˚ 2' x 4' Microperforated mesh white lamp shields /grey solid louver blades, 3-lamp 32W T8 RCR 5½" (140mm) 1 3 5 7 9 C.U. 47 37 29 23 19 Candlepower Curve Reference data Efficiency 40.0% Spacing ratio 1.3 Electronic ballast • Choice of three flat blade louvers. (See bottom of page for ordering information). Options & accessories page 4.72 + 4.130 Ballast: Specify voltage (120, 277 or UNV) and type and add as suffix, e.g. UNVHI. 600 QVS2GPTLG332UNVH3 • Lens overlay preventing direct view of the lamp source. • Suited to row mounting for a continuous cove effect. 60˚ 300 Input watts (120V) 62.0W Ballast factor 0.88 48" (1220mm) • Seamless semi-specular metallic reflector with lengthwise ridges. Ballast type Electronic 40W TT5 IB 40W TT5 PB 50W TT5 BP T5 PF 55W TT5 BF T8 (32W only) PS IGEN DALI DA 3 LPB 40W TT5 I3 60˚ 600 Input watts (120V) 85.0W Ballast factor 0.88 1200 PowerSpec HDF dimming T8 HI 3 LPB T8 H3 T5 PG LPB = Number of lamps per ballast. 1441 1800 48" (1220mm) QVS2GPTLG2FTUNVIB 24" (610mm) 30˚ 2' x 2' Microperforated mesh white lamp shields /grey solid louver blades, 2-lamp 40W TT5 RCR 5½" (140mm) 1 3 5 7 9 C.U. 43 34 27 22 17 Candlepower Curve Reference data Drywall kit: C onversion kit for 2' x 4' unit: FK92X4. Conversion kit for 2' x 2' unit: FK92X2. Emergency/wiring options: For special wiring, fusing, electronic dimming ballasts, consult factory. Fusing: Suffix: A (Internal fast-blow fusing). Suffix: C (Internal slow-blow fusing). Efficiency 40.7% Spacing ratio 1.4 Electronic ballast 60˚ 400 Input watts (120V) 74.0W Ballast factor 0.88 800 939 24" (610mm) 1200 Ordering information Type Static* Static* Size Lamp qty –type Lamp watts 30˚ Catalog no. QVS2GPTLG232 QVS2GPTLG332 QVS2GPTLG228 QVS2GPTLG328 QVS2GPTLG254 QVS2GPTLG354 2' x 4' 2-T8 3-T8 2-T5 3-T5 2-T5HO 3-T5HO 32W 32W 28W 28W 54W 54W 2' x 2' 2-TT5 3-TT5 2-T8 3-T8 2-T5HO 3-T5HO 40, 50, 55W QVS2GPTLG2FT 40, 50, 55W QVS2GPTLG3FT 17W QVS2GPTLG217 17W QVS2GPTLG317 24W QVS2GPTLG224 24W QVS2GPTLG324 Example QVS2GPTLG2FT Alter Metalyte Louver Direct/indirect recessed w/mesh white lamp shields/grey solid louver blades UNV IB Voltage Ballast Options 120 = 120V See page 4.51 See page 4.51 277 = 277V and page 4.72 UNV= 120-277V Comprehensive lighting catalog 7th Edition 4.51 Linear recessed and surface lighting – Professional Alter OPL 2' x 4' Direct/indirect static curved opal lens recessed luminaires Sober design, high performance and Alter’s trademark balanced brightness come together beautifully in Alter OPL 2' x 4'. Exhibiting pure form, the one-piece opal acrylic lens produces soft glowing illumination that uniformly lights all surfaces, while creating a feeling of spaciousness. Exceptional value for lighting efficiency provides increased specification Features • 80.2% efficient three lamp 32W T8 2' x 4' luminaire. • Alter soft white film inside of opal acrylic lamp shield conceals lamp image, providing balance between reflected and direct light. • Seamless welded form: curved top and side reflectors are formed together without any gaps or visual barriers. opportunities. Models with up to 3 high-output lamps ensure extra-wide lighting distribution in larger open spaces, including workplaces with no or low partitions. Also, this luminaire is well-suited to continuous rows, creating a continuous cove effect that enhances architectural perspectives. QVS2GOLOP332UNVH3 RCR 5½" (140mm) 1 3 5 7 9 • No visible welding, screws, latches, springs, hooks, rivets or plastic supports. • 95% reflective Alter soft white paint finish and specular interior reflector. 2' x 4' One-piece opal acrylic lamp shields, 3-lamp 32W T8 24" (610mm) • 5 ½" deep one-piece body for easy installation. C.U. 78 65 55 47 40 • Swing-down lamp shield for easy relamping. Efficiency 80.2% Spacing ratio 1.3 Electronic ballast 2283 2400 48" (1220mm) • Fully recessed luminaire and lamp compartment. 30˚ Ordering information • Air handling version unavailable page 4.72 + 4.130 Type Size Ballast: Specify voltage (120, 277 or UNV) and type and add as suffix, e.g. UNVHI. Static Ballast type Electronic 60˚ 1600 • Fits standard T-grid, exposed slot T-grid and drywall ceilings. Options & accessories 800 Input watts (120V) 86.9W Ballast factor 0.9 • Easy access to ballast through lamp compartment. • Luminaire can be row mounted. Candlepower Curve Reference data PowerSpec HDF dimming T8 HI T5 PF 3 LPB T8 H3 PS T5 PG T5 LPB = Number of lamps per ballast. Drywall kit: Conversion kit for 2' x 4' unit: FK92X4. Example 2' x 4' Lamp qty –type 2-T8 3-T8 2-T5 3-T5 2-T5HO 3-T5HO QVS2GOLOP232 Alter OPL Direct/indirect recessed w/one-piece opal lens Lamp watts Catalog no. QVS2GOLOP232 QVS2GOLOP332 QVS2GOLOP228 QVS2GOLOP328 QVS2GOLOP254 QVS2GOLOP354 32W 32W 28W 28W 54W 54W UNV HI Voltage Ballast 120 = 120V See page 4.52 277 = 277V (347V N/A) UNV= 120-277V Options See page 4.52 and page 4.72 Emergency/wiring options: For special wiring, fusing, electronic dimming ballasts, consult factory. Fusing: Suffix: A (Internal fast-blow fusing). Suffix: C (Internal slow-blow fusing). 4.52 Philips Lightolier For complete specification information visit www.lightolier.com Professional – Linear recessed and surface lighting Alter OPL 2' x 2' Direct/indirect static curved opal lens recessed luminaires The one-piece opal acrylic lens features an attractive, uncluttered, flush-ceiling, shadowless look that adds elegance to modern interiors. What’s more, Alter OPL offers excellent value, while providing superior efficiency. Alter OPL is ideal for open-plan environments, private offices, entrance halls and public spaces. Features • Alter soft white film inside of opal acrylic lamp shield conceals lamp image, providing balance between reflected and direct light. QVS2GOLOP2FTUNVIB 2' x 2' One-piece opal acrylic lamp shields, 2-lamp 40W TT5 RCR 5½" (140mm) 1 3 5 7 9 24" (610mm) C.U. 81 63 50 40 30 Candlepower Curve Reference data Efficiency 71.8% Spacing ratio 1.2 Electronic ballast 600 60˚ 1611 1800 • Easy access to ballast through lamp compartment. Static Example 2' x 2' • Fits standard T-grid, exposed slot T-grid and drywall ceilings. 30˚ • Fully recessed luminaire and lamp compartment. • Optional hold-down clips available. • Luminaire can be row mounted. Ordering information Size • 5 ½" deep one-piece body for easy installation. • Swing-down lamp shield for easy relamping. 1200 Type • No visible welding, screws, latches, springs, hooks, rivets or plastic supports. • 95% reflective Alter soft white paint finish and specular interior reflector. Input watts (120V) 64.6W Ballast factor 0.88 24" (610mm) • Seamless welded form: curved top and side reflectors are formed together without any gaps or visual barriers. • Air handling version not available Lamp qty –type 1-TT5 2-TT5 3-TT5 2-T8 3-T8 2-T5HO 3-T5HO QVS2GOLOP2FT Alter OPL Direct/indirect recessed w/one-piece opal lens Lamp watts Catalog no. Options & accessories 40, 50, 55W QVS2GOLOP1FT 40, 50, 55W QVS2GOLOP2FT 40, 50, 55W QVS2GOLOP3FT 17W QVS2GOLOP217 17W QVS2GOLOP317 24W QVS2GOLOP224 24W QVS2GOLOP324 UNV Ballast type Electronic IB Voltage Ballast 120 = 120V See page 4.53 277 = 277V UNV= 120-277V page 4.72 + 4.130 Ballast: Specify voltage (120, 277 or UNV) and type and add as suffix, e.g. UNVIB. Options See page 4.53 and page 4.72 PowerSpec HDF dimming 40W TT5 IB 40W TT5 PB 50W TT5 BP T5 PF 55W TT5 BF PS T8 3 LPB 40W TT5 I3 T8 HI 3 LPB T8 H3 Program start T5 PG LPB = Number of lamps per ballast. Drywall kit: Conversion kit for 2' x 2' unit: FK92X2. Hold down clips: Standard T 15/16" only: QVS-HD. Emergency/wiring options: For special wiring, fusing, electronic dimming ballasts, consult factory. Fusing: Suffix: A (Internal fast-blow fusing). Suffix: C (Internal slow-blow fusing). Comprehensive lighting catalog 7th Edition 4.53 Linear recessed and surface lighting – Professional Alter Waves 2' x 4' & 2' x 2' Direct/indirect static side basket recessed luminaires Architectural styling and curved door elements come together in this unique luminaire that provides balanced lighting environment. Dual-door light effect offers visual interest and soft awareness of the lighting element. Twin lateral opposing curved door lamp shields and Alter Soft Light reflector create soft light to enhance any decor. QVL2GPFSS232UNVHI Features RCR 5½" (140mm) 1 3 5 7 10 • Microperforated mesh lamp shields provide soft awareness of light source. • Curved door lateral lamp shields project light upwards to reflector and provide indirect light. 2' x 4' Microperforated mesh dual lateral side lamp shields, 2-lamp 32W T8 24" (610mm) • 95% reflective Alter soft white paint finish. C.U. 66 48 37 30 23 • Fully recessed lamp shields and reflector. Candlepower Curve Reference data Efficiency 64.7% Spacing ratio 1.4 Electronic ballast 60˚ 400 Input watts (120V) 62.0W Ballast factor 0.88 800 • Curved top and sides of reflector are formed together without any gaps or visual barriers. 1066 • No visible welding, screws, latches, springs, holes, rivets or plastic supports. 1200 48" (1220mm) 30˚ • Optional solid or curved lamp shields. • Alter soft white film inside of microperforated mesh lamp shield conceals lamp image, providing balance between reflected and direct light. QVL2GPFSS432UNVH4 RCR 5½" (140mm) 1 3 5 7 10 • Swing-down lamp shield for easy relamping. • Easy access to ballast. • Fits standard T-grid, exposed slot-T-grid and drywall ceilings (see page 4.218). 2’ x 4’ Microperforated mesh dual lateral side lamp shields, 4-lamp 32W T8 24" (610mm) C.U. 60 45 35 28 20 • Not suitable for row mounting Options & accessories Efficiency 58.6% Spacing ratio 1.3 Electronic ballast 60˚ 800 Input watts (120V) 112.0W Ballast factor 0.88 1600 page 4.72 + 4.130 1993 Ballast: Specify voltage (120, 277 or UNV) and type and add as suffix, e.g. UNVHI. Ballast type Electronic Candlepower Curve Reference data PowerSpec HDF dimming 40W TT5 IB 40W TT5 PB 50W TT5 BP T5 PF 55W TT5 BF PS T8 HI 3 LPB T8 H3 4 LPB T8 H4 T8 2400 48" (1220mm) QVL2GPFSS2FTUNVIB 2' x 2' Microperforated mesh dual lateral side lamp shields, 2-lamp 40W TT5 RCR 5½" (140mm) 1 3 5 7 10 24" (610mm) 30˚ C.U. 47 36 28 22 178 Candlepower Curve Reference data Efficiency 45.2% Spacing ratio 1.3 Electronic ballast 300 60˚ Input watts (120V) 74.0W Ballast factor 0.88 600 Program start T5 PG 24" (610mm) LPB = Number of lamps per ballast. Drywall kit: C onversion kit for 2' x 4' unit: FK92X4. Conversion kit for 2' x 2' unit: FK92X2. Hold down clips: Standard T 15/16" only: QVS-HD. 30˚ Ordering information Type Size Lamp qty –type Static 2' x 4' 2-T8 2-T5HO 4-T5 4-T5HO 2-T8 4-T8 Static 2' x 2' 2-TT5 2-T5HO Emergency/wiring options: For special wiring, fusing, electronic dimming ballasts, consult factory. Fusing: Suffix: A (Internal fast-blow fusing). Suffix: C (Internal slow-blow fusing). 851 900 Lamp watts Catalog no. QVL2GPFSS228 QVL2GPFSS254 QVL2GPFSS428 QVL2GPFSS454 QVL2GPFSS232 QVL2GPFSS432 28W 54W 28W 54W 32W 32W 40, 50, 55W QVL2GPFSS2FT 24W QVL2GPFSS224 * For optional curved lamp shield replace Wave lamp shield SS with SR. Example QVL2GPFSS2FT Alter Waves Direct/indirect recessed w/microperforated mesh dual lateral lamp shields 4.54 Philips Lightolier UNV IB Voltage Ballast 120 = 120V See page 4.54 277 = 277V UNV= 120-277V Options See page 4.54 and page 4.72 For complete specification information visit www.lightolier.com Professional – Linear recessed and surface lighting Alter Dome 2' x 2' Direct/indirect static round recessed luminaires Architectural luminaire with uniquely styled optic features “circle in square” form. The open look, elegant appearance and balanced soft light provide a distinctive touch. Rotating luminaires create patterns of light that add variety to the decor. QVC2GPFOS1FTUNVBP 2' x 2' Microperforated mesh lamp shields, 1-lamp 50W TT5 RCR C.U. 1 3 5 7 10 56 42 33 27 21 Candlepower Curve Reference data Efficiency 53.9% Spacing ratio 1.4 Electronic ballast Input watts (120V) 53.7W Ballast factor 0.88 23 ¹³¹6" (605mm) 6 ½" (165mm) 2 ⅛" (54mm) 60˚ 300 24" (610mm) • Swing-down lamp shield for easy relamping. • Alter soft white film on inside of microperforated mesh lamp shield conceals lamp image providing balance between reflected and direct light. 2 ⅛" (54mm) 600 669 900 30˚ • 95% reflective Alter soft white paint finish and specular interior reflector Options & accessories page 4.72 + 4.130 Ballast: Specify voltage (120, 277 or UNV) and type and add as suffix, e.g. UNVHI. 5 ½" (140mm) Ballast type 24" (610mm) QVC2GPFOS1FTUNVIB • Utilizes one high-lumen TT5 compact fluorescent lamp. • Microperforated mesh lamp shield provides soft awareness of the light source. 23 ¹³¹6" (605mm) 6 ½" (165mm) Features 5 ½" (140mm) Electronic 2' x 2' Microperforated mesh lamp shields, 1-lamp 40W TT5 RCR C.U. 1 3 5 7 10 60 45 36 29 22 Candlepower Curve Reference data Efficiency 58.3% Spacing ratio 1.4 Electronic ballast 200 60˚ Input watts (120V) 47.3W 2 ⅛" Ballast factor 0.88 (54mm) 400 23 ¹³¹6" (605mm) 6 ½" (165mm) 2 ⅛" (54mm) 23 ¹³¹6" (605mm) 554 600 40W TT5 IB 50W TT5 BP 55W TT5 BF LPB = Number of lamps per ballast. Drywall kit: Conversion kit for 2' x 2' unit: FK92X2. Hold down clips: Standard 15/16" only: QVS-HD. Emergency pack: Not available. Fusing: Suffix: A (Internal fast-blow fusing). Suffix: C (Internal slow-blow fusing). 30˚ 5 ½" (140mm) 6 ½" (165mm) 24" (610mm) Ordering information Type Static Example Size Lamp qty –type 2' x 2' 24" (610mm) 1-TT5 QVC2GPFOS1FT Alter Dome Direct/indirect recessed w/microperforated mesh lamp shields 5 ½" (140mm) Lamp watts Catalog no. 40, 50, 55W QVC2GPFOS1FT UNV BP Voltage Ballast 120 = 120V See page 4.55 277 = 277V UNV= 120-277V Options See page 4.55 and page 4.72 Comprehensive lighting catalog 7th Edition 4.55 Linear recessed and surface lighting – Professional Alter Windows 2' x 2' Direct/indirect static symmetrical recessed luminaires The gradations of light and gently curved square lamp shields of Alter Windows make a bold design statement. The non-directional design of the Alter Windows shield helps maintain the architectural look of a space. The multi-textured lamp shield and Alter Soft White reflector combine to create visual interest and gradations of light within a single lighting element. Features QVS2GPASQ2TTUNVTD • Utilizes two triple tube (TTT) lamps. • Alter soft white film inside of microperforated lamp shield conceals lamp image and provides balance between reflected and direct light. • Opaque lens provides a gradation of light effect that creates visual interest and architectural detail. • Unique symmetrical design elements. 2' x 2' Recessed microperforated mesh square lamp shield, 2-lamp 42W TTT RCR C.U. 1 3 5 7 10 49 39 31 24 18 23 ¹3¹6" (605mm) • Fits standard T-grid, exposed slot-T-grid and drywall ceilings (see page 4.218). Candlepower Curve Reference data Efficiency 46.7% Spacing ratio 1.4 Electronic ballast 300 60˚ Input watts (120V) 71.6W Ballast factor 1 600 • Swing-down design for easy relamping. 732 • No visible welding, screws, latches, springs, holes, rivets or plastic supports. 900 30˚ • For wall version (see next page). Options & accessories 23 ¹3¹6" (605mm) page 4.72 + 4.130 Ballast: Specify voltage (120, 277 or UNV) and type and add as suffix, e.g. UNVTD. 8" (203mm) 5 ½" (140mm) Ballast type Electronic 26W TTT TB 32W TTT TC 42W TTT TD PowerSpec HDF dimming 40W TTT PD 24" (610mm) Ordering information Drywall kit: C onversion kit for 2' x 2' unit: FK92X2. Type Size Hold down clips: Standard T 15/16" only: QVS-HD. Static 2' x 2' Emergency pack: Not available. Example Lamp qty –type 2-TTT QVS2GPASQ2TT Alter Waves Direct/indirect recessed w/solid white perimeter lamp shield / white mesh center 4.56 Philips Lightolier Lamp watts Catalog no. 26, 32, 42W QVS2GPASQ2TT UNV TD Voltage Ballast 120 = 120V See page 4.56 277 = 277V UNV= 120-277V Options See page 4.56 and page 4.72 For complete specification information visit www.lightolier.com Professional – Linear recessed and surface lighting Alter Windows Wall 13 ½" x 13 ½" Direct/indirect recessed luminaires Matches ceiling luminaire styling. Protruding design projects light backwards to wall, creating a splash of light that surrounds the luminaire. Attention is focused on the gradations of light that frame the translucid center. QVW1SPASQ2QTUNVF4 13 ½ " (343mm) 13 ½ " (343mm) 13 ½" x 13 ½" Surface wall microperforated mesh square lamp shield, 2-lamp 18W QT RCR C.U. 1 3 5 7 10 35 24 18 14 10 Candlepower Curve Reference data Efficiency 40.2% 135˚ Electronic ballast Input watts (120V) 38.3W Ballast factor 1 • Utilizes two quad tube (QT) lamps for surface wall. • Alter soft white film inside of microperforated lamp shield conceals lamp image and provides balance between reflected and direct light. 0 50 13 ½ " (343mm) 13 ½ " (343mm) 200 Type Size Static 13 ½" x 13 ½" 45˚ • Unique symmetrical design elements. • No visible welding, screws, latches, springs, holes, rivets or plastic supports. • Compact ADA compliant wall sconce form (4" deep) makes it ideal for mounting on columns and for use where wall space is limited Ordering information Example • Opaque lens provides a gradation of light effect that creates visual interest and architectural detail. 150 4" (102mm) 4" (102mm) Features Lamp qty –type 2-QT QVW1SPASQ2QT Alter Windows Direct/indirect recessed w/solid white perimeter lamp shield/white mesh center Lamp watts Options & accessories Catalog no. 18W QVW1SPASQ2QT UNV F4 Voltage Ballast 120 = 120V See page 4.57 277 = 277V UNV= 120-277V Ballast: Specify voltage (120, 277 or UNV) and type and add as suffix, e.g. UNVF4. Options See page 4.57 and page 4.72 F4: E lectronic P.S., 1 or 2 lamps per ballast 18W Quad Tube. QD: 18W QT PowerSpec HDF dimming. (Not available in 347V) Emergency pack: Not available. Comprehensive lighting catalog 7th Edition 4.57 Linear recessed and surface lighting – Professional Alter TileLyte 2' x 2' Direct/indirect recessed static luminaires with glass lens Alter TileLyte comprises a recessed 2' x 2' square of radiant light, softened by an interior opal film. It installs flush with the ceiling using decorative hardware, while concealing T-bars. This textured lighting element features glass with chamfered edges, bringing pure sophistication to modern interiors. Easy Maintenance • Easy-to-remove thumbscrews facilitate lowering of glass shield. QVD2GGLOP3FTUNVI3 • Aircraft-cable safety chain attaches behind each thumbscrew to hold glass shield when open. • Safety chains can be removed for easy cleaning, ballast access and lamp replacement RCR C.U. 1 3 5 7 9 52 41 33 27 20 24 " (610mm) Elegant Compatibility Reference data 2' x 2' Glass with opal film, 3-lamp 40W TT5 24 " (610mm) Candlepower Curve Efficiency 48.9% Spacing ratio 1.2 Electronic ballast 800 Input watts (120V) 99.8W Ballast factor 0.88 24" (610mm) • Fits all ceiling grid types (standard T, slim-T and slot-T). 2400 5" (127mm) • Four decorative stainless-steel thumbscrews creating discreet visual interest at the ceiling line 5" (127mm) • Unlimited ability to create luminous ceiling patterns. Options & accessories page 4.72 + 4.130 Ballast: Specify voltage (120, 277 or UNV) and type and add as suffix, e.g. UNVPG. Ballast type Electronic PowerSpec HDF dimming 40W TT5 IB 40W TT5 PB 50W TT5 BP T5 PF 55W TT5 BF T5 PG 30˚ 24" (610mm) 24" (610mm) Endless Possibilities • Creative side-by-side installations can generate rows, squares, rectangles, "L" shapes, "T" shapes and other geometric figures 1600 1865 • Blends in with regular flat-edge and aesthetic recessededge ceiling tiles. • Configuration versatility complements ceiling designs, adapts well to architectural interiors. 60˚ 5" (127mm) Ordering information Type Static 24" (610mm) Size Lamp qty –type 2' x 2' 24" (610mm) Example 24" (610mm) Lamp watts 3-TT5 40, 50, 55W 5" 3-T5 (127mm) 14W 3-T5 24W 4-T5 14W 4-T5 24W QVD2GGLOP3FT Alter TileLyte Direct/indirect recessed glass with opal film UNV Catalog no. QVD2GGL0P3FT QVD2GGL0P314 QVD2GGL0P324 QVD2GGL0P414 QVD2GGL0P424 I3 Voltage Ballast 120 = 120V See page 4.58 277 = 277V UNV= 120-277V Options See page 4.58 and page 4.72 3 LPB 40W TT5 I3 LPB = Number of lamps per ballast. Dimming ballast recommended with certain configurations. Drywall kit: C onversion kit for 2' x 2' unit: FK92X2. Hold down clips: Standard T 15/16" only: QVS-HD. Lens replacement: Available as a complete assembly. Order cat. no.: QVD22GLOP. Fusing: Suffix: A (Internal fast-blow fusing). Suffix: C (Internal slow-blow fusing). 4.58 Philips Lightolier For complete specification information visit www.lightolier.com Professional – Linear recessed and surface lighting Alter TileLyte 2' x 2' Direct/indirect recessed static luminaires with glass lens Comprehensive lighting catalog 7th Edition 4.59 Linear recessed and surface lighting – Professional Alter Slim Semi-recessed 2' x 4' & 2' x 2' Direct/indirect recessed static luminaires This slimly profiled luminaire adds beauty and visual interest to the ceiling. With their gently curved fluid architectural details, they blend into the ceiling perspective. For applications where plenum depth is limited. The combined use of style matched Slim Semi-recessed and Slim Surface luminaires can provide the perfect solution. QVH2GPFOS4FTUNVIB 2' x 4' Slim semi-recessed microperforated mesh lamp shields, 4-lamp 40W TT5 Candlepower Curve Reference data Efficiency 52.6% Spacing ratio 1.5 23 ¹5¹6 (608mm) 23 ¹5¹6" (608mm) Electronic ballast Input watts (120V) 142.0W Ballast factor 0.88 11 ¹5¹6" (303mm) Features 47 ¹3¹6" (1214mm) • Microperforated mesh lamp shields provide a soft awareness of the light source. • Alter soft white film on inside of microperforated mesh lamp shields conceal lamp image providing balance between reflected and direct light. • Luminaire is 2-3/16" total depth for easy installation into shallow plenum. 2 3¹6 (56mm) 24" (610mm) QVH2GPFOS2FTUNVIB RCR C.U. 1400 1 3 5 7 9 53 40 32 25 21 1706 Efficiency 52.6% Spacing ratio 1.5 23 ¹3¹6" (605mm) Electronic ballast • T8 not available 23 ¹ ¹6"(605mm) 3 Options & accessories page 4.72 + 4.130 2 ¹6" (56mm) 3 Ballast: Specify voltage (120, 277 or UNV) and type and add as suffix, e.g. UNVIB. 300 60˚ Input watts (120V) 67.0W Ballast factor 0.88 11 ¹5¹6" (303mm) • Can be row mounted. 30˚ Candlepower Curve Reference data • Easy access to ballast through lamp compartment. • Optional drop-down visual element. 2100 2' x 2' Slim semi-recessed microperforated mesh lamp shields, 2-lamp 40W TT5 • Swing-down lamp shields for easy relamping. • Fits standard T-grid, exposed slot T-grid and drywall ceilings. 60˚ 700 24" (610mm) RCR C.U. 1 3 5 7 9 53 39 30 25 21 600 853 900 30˚ Ordering information Ballast type Electronic PowerSpec HDF dimming 40W TT5 IB 40W TT5 PB 50W TT5 BP T5 PF 55W TT5 BF T5 PG Type Size Static microperforated mesh lamp shields Recessed ceiling depth 2' x 4' Emergency/wiring options: For special wiring, fusing, electronic dimming ballasts, consult factory. Fusing: Suffix: A (Internal fast-blow fusing). Suffix: C (Internal slow-blow fusing). Clear acrylic plate drop down element Clear polished acrylic drop-down visual element with projected color face. Substitute acrylic color suffix in place of open slot only. Static microperforated mesh lamp shields Example 2' x 2' Lamp watts Catalog no. 2 ¼" 2-TT5 4-TT5 2-T5 2-T5HO 3-T5 3-T5HO 40, 50, 55W 40, 50, 55W 28W 54W 28W 54W QVH2GPFOS2FL QVH2GPFOS4FT QVH2GPFOS228 QVH2GPFOS254 QVH2GPFOS328 QVH2GPFOS354 2 ¼" 2-T5HO 3-T5HO 1-TT5 2-TT5 24W 24W 40, 50, 55W 40, 50, 55W QVH2GPFOS224 QVH2GPFOS324 QVH2GPFOS1FT QVH2GPFOS2FT Drywall kit: C onversion kit for 2' x 2' unit: FK92X2. Hold down clips: Standard T 15/16" only: QVS-HD. Add appropriate Suffix: PF (Perforated) or SD (Solid) (e.g. QVH2GPF / QVH2GSD). Lamp qty –type QVH2GPFOS2FT Alter Slim Semi-recessed Direct/indirect recessed with microperforated mesh lamp shields UNV IB Voltage Ballast 120 = 120V See page 4.60 277 = 277V UNV= 120-277V Options See page 4.60 and page 4.72 Suffix: GC (clear) GB (blue) GG (green) GR (red) e.g. QVH2GPFOS (OS = Open Slot) e.g. QVH2GPFGB (GB = Blue Acrylic) For other colors or special orders, consult your Philips Lightolier representative. 4.60 Philips Lightolier For complete specification information visit www.lightolier.com Professional – Linear recessed and surface lighting Alter Slim Semi-recessed 1' x 4' Direct/indirect recessed static luminaires This slimly profiled luminaire adds beauty and visual interest to the ceiling. With their gently curved fluid architectural details, they blend into the ceiling perspective. For applications where plenum depth is limited. The combined use of style matched Slim Semi-recessed 23 ¹ ¹ " (608mm) and Slim Surface luminaires can provide 5 ¹ ¹ " the perfect solution. 11 ¹ ¹ " 5 6 5 3 6 (150mm) 47 ¹ ¹ " (1215mm) QVH1GPFOS2FTUNVIB 3 1' x 4' Slim semi-recessed microperforated mesh lamp shields, 2-lamp 40W TT5 6 3 9¹6" (90mm) 12" (305mm) 6 (300mm) RCR C.U. 1 3 5 7 10 50 38 30 24 18 Candlepower Curve Reference data Efficiency 47.5% Spacing ratio 1.4 Electronic ballast 300 60˚ Input watts (120V) 68.0W Ballast factor 0.9 11 ¹3¹6" (300mm) 900 • Alter soft white film on inside of microperforated mesh lamp shields conceal lamp image providing balance between reflected and direct light. • Swing-down lamp shields for easy relamping. 800 5 ¹5¹6" (150mm) • Microperforated mesh lamp shields provide a soft awareness of the light source. • Luminaire is 3-9/16" total depth for easy installation into shallow plenum. 600 23 ¹5¹6" (608mm) Features 30˚ • Easy access to ballast through lamp compartment. • Fits standard T-grid, exposed slot T-grid and drywall ceilings. • Optional drop-down visual element. • Can be row mounted 47 ¹3¹6" (1215mm) Options & accessories Ordering information 3 9¹6" (90mm) Type Size Recessed ceiling depth 12" (305mm) Static microperforated mesh lamp shields Example 1' x 4' 3-9/16" QVH1GPFOS2FT Alter Slim Semi-recessed Direct/indirect recessed with microperforated mesh lamp shields page 4.72 + 4.130 Ballast: Specify voltage (120, 277 or UNV) and type and add as suffix, e.g. UNVIB. Lamp qty –type 2-TT5 2-T5 2-T5HO UNV Lamp watts Catalog no. 40, 50, 55W QVH1GPFOS2FT 28W QVH1GPFOS228 54W QVH1GPFOS254 IB Voltage Ballast 120 = 120V See page 4.61 277 = 277V UNV= 120-277V Options See page 4.61 and page 4.72 Ballast type Electronic PowerSpec HDF dimming 40W TT5 IB 40W TT5 PB 50W TT5 BP T8 PS 55W TT5 BF T5 PG Drywall kit: C onversion kit for 2' x 2' unit: FK91X4. Hold down clips: Standard T 15/16" only: QVS-HD. Add appropriate Suffix: PF (Perforated) or SD (Solid) (e.g. QVH1GPF / QVH1GSD). Emergency/wiring options: For special wiring, fusing, electronic dimming ballasts, consult factory. Fusing: Suffix: A (Internal fast-blow fusing). Suffix: C (Internal slow-blow fusing). Clear acrylic plate drop down element Clear polished acrylic drop-down visual element with projected color face. Substitute acrylic color suffix in place of open slot only. Suffix: GC (clear) GB (blue) GG (green) GR (red) e.g. QVH2GPFOS (OS = Open Slot) e.g. QVH2GPFGB (GB = Blue Acrylic) For other colors or special orders, consult your Philips Lightolier representative. Comprehensive lighting catalog 7th Edition 4.61 Linear recessed and surface lighting – Professional Alter Slim Surface 2' x 4' & 2' x 2' Direct/indirect recessed luminaires These slimly profiled luminaires add beauty and visual interest to the ceiling. With their gently curved fluid architectural details, they blend into the ceiling perspective. For applications where plenum depth is limited. The combined use of style matched slim semi-recessed and slim surface luminaires can provide the perfect solution. Features • Alter soft white film on inside of microperforated mesh lamp shields conceal lamp image providing balance between reflected and direct light. QVF2SPFOS2FTUNVIB • Utilize the same reflector and optics design as Slim Semi-recessed model providing the same lighting performance. Luminaire with its contoured housing gives the visual perception of a very low-profile luminaire. 2' x 2' Slim surface microperforated mesh lamp shields, 2-lamp 40W TT5 24" (610mm) Ceiling RCR C.U. 1 3 5 7 10 53 39 30 25 19 Efficiency 52.6% Spacing ratio 1.5 Electronic ballast 600 25 ¹6" (650mm) 9 • 95% reflective Alter soft white paint finish and specular interior reflector. 60˚ 300 Input watts (120V) 67.0W Ballast factor 0.88 2 ¼" (57mm) • Contoured housing depth only 2 1/4". Total depth 3 15/16". Candlepower Curve Reference data 853 900 30˚ • Swing-down lamp shields for easy relamping. Easy access to ballast through lamp compartment. QVF2SPFOS4FTUNVIB • Fits standard T-grid, exposed slot T-grid and drywall ceilings. • No visible welding, screws, latches, springs, hooks, rivets or plastic supports. RCR • T8 not available. 1 2 ¼" 3 (57mm) 5 7 10 25 9¹6" (650mm) Options & accessories 2' x 4' Surface wall microperforated mesh lamp shields, 4-lamp 40W TT5 page 4.72 + 4.130 Ballast: Specify voltage (120, 277 or UNV) and type and add as suffix, e.g. UNVIB. C.U. Efficiency 51.0% Spacing ratio 1.5 Electronic ballast 60˚ 700 Input watts (120V) 130.0W Ballast factor 0.88 Ceiling 1400 1854 Ballast type Electronic IB 40W TT5 PB 50W TT5 BP T5 PF 55W TT5 BF T5 PG Drywall kit: C onversion kit for 2' x 4' unit: FK92X4. Conversion kit for 2' x 2' unit: FK92X2. Emergency/wiring options: For special wiring, fusing, electronic dimming ballasts, consult factory. Fusing: Suffix: A (Internal fast-blow fusing). Suffix: C (Internal slow-blow fusing). 1-11/16" = Depth of basket from bottom of surface frame 2-1/4" = Full depth of fixture from ceiling surface Type Size Clear acrylic plate drop down element 2' x 2' Clear polished acrylic drop-down visual element with projected color face. Substitute acrylic color suffix in place of open slot only. Example Philips Lightolier 2 ¼" (57mm) 3 ¹5¹6" (100mm) 1 ¹¹6" (43mm) Ordering information Static Microperforated Mesh Lamp Shields For other colors or special orders, consult your Philips Lightolier representative. Ceiling Allow 3" for recessed T-bar mounting Actual recessed luminaire depth ⅝" 2' x 4' e.g. QVH2GPFOS (OS = Open Slot) e.g. QVH2GPFGB (GB = Blue Acrylic) 30˚ Alter Slim Surface: added profile dimensions Static Microperforated Mesh Lamp Shields Suffix: GC (clear) GB (blue) GG (green) GR (red) 2100 48" (1220mm) PowerSpec HDF dimming 40W TT5 4.62 Candlepower Curve Reference data 52 39 31 25 19 Recessed ceiling depth Lamp qty –type Lamp watts Catalog no. 3 15 ⁄16" 2-TT5 4-TT5 2-T5 2-T5HO 3-T5 3-T5HO 40, 50, 55W 40, 50, 55W 28W 54W 28W 54W QVF2SPFOS2FT QVF2SPFOS4FT QVF2SPFOS228 QVF2SPFOS254 QVF2SPFOS328 QVF2SPFOS354 3 ⁄ " 1-TT5 2-TT5 2-T5HO 3-T5HO 40, 50, 55W 40, 50, 55W 24W 24W QVF2SPFOS1FT QVF2SPFOS2FT QVF2SPFOS224 QVF2SPFOS324 15 16 QVF2SPFOS2FT Alter Slim Surface Direct/indirect recessed with microperforated mesh lamp shields UNV IB Voltage Ballast 120 = 120V See page 4.62 277 = 277V UNV= 120-277V Options See page 4.62 and page 4.72 For complete specification information visit www.lightolier.com Professional – Linear recessed and surface lighting Alter Slim Square 2' x 2' Direct/indirect recessed luminaires Featuring an attractive inset frame, Alter Slim Square produces a floating effect while hugging the ceiling line. This surface-mount fluorescent luminaire displays a sleek profile with architectural detailing that blends into most environments. For balanced brightness applications where plenum depth is very limited. QVB2SPGOS2FTUNVIB 2' x 2' Microperforated mesh lamp shields, 2-lamp 40W TT5 Candlepower Curve Reference data Efficiency 50.5% Spacing ratio 1.5 24" (610mm) Electronic ballast 300 Ceiling ¾" (19mm) 28 ¹¹6" (713mm) 2 5¹6" (59mm) RCR C.U. 1 3 5 7 10 52 39 31 25 20 600 876 900 Type Size Static with white body microperforated mesh white lamp shields 2' x 2' Static with titanium body microperforated mesh white lamp shields 2' x 2' Lamp qty –type Lamp watts • Microperforated mesh lamp shield. • Available either in white or titanium painted finish. Catalog no. • Economical construction providing excellent value. 1-TT5 2-TT5 40, 50, 55W 40, 50, 55W QVB2SPWOS1FT QVB2SPWOS2FT 1-TT5 2-TT5 40, 50, 55W 40, 50, 55W QVB2SPGOS1FT QVB2SPGOS2FT Alter Slim Semi-recessed Direct/indirect recessed with microperforated mesh lamp shields Options & accessories UNV IB Voltage Ballast 120 = 120V See page 4.63 277 = 277V UNV= 120-277V Options See page 4.63 and page 4.72 1-9/16" (4 0m ) 3/4" (9m m page 4.72 + 4.130 Ballast: Specify voltage (120, 277 or UNV) and type and add as suffix, e.g. UNVIB. Ballast type Electronic For Solid Lamp Shield replace PW or PG by SW or SG. QVB2SPGOS2FT 30˚ Features Ordering information Example 60˚ Input watts (120V) 64.5W Ballast factor 0.88 40W TT5 IB 50W TT5 BP 55W TT5 BF PowerSpec HDF dimming 40W TT5 PB m) 3m m) 1-11/16" (4 Slim Square 3/4" contoured frame gives the luminaire a very low profile visual perception. Comprehensive lighting catalog 7th Edition 4.63 Linear recessed and surface lighting – Professional Alter Concept Direct/indirect recessed luminaires 4.64 Philips Lightolier For complete specification information visit www.lightolier.com Professional – Linear recessed and surface lighting Alter Concept Direct/indirect recessed luminaires Less bulk. Less weight. More performance – up to 92.7% efficient. More sustainable lighting opportunities, especially in shallow and cluttered plenums. And more lighting value for today’s modern interiors. Lower profile: 3 ⅝" vs. 5 ½" Less is more • Suited to sustainable building trend favouring less materials and shallower plenums with 3 ⅝" depth ideal for restricted ceiling space (standard Alter Classic housing is 5 ½"). • Streamlined lightweight construction Alter Concept luminaires are about 30% lighter than regular Alter models with 5 ½" housings. • Material-saving approach These products feature less fuel consumption for transportation. Also, they use considerably less steel and less packaging than standard luminaires. • Architectural flexibility Alter Concept luminaires can help reduce floorto-floor heights and overall building elevation, while minimizing the use of energy and resources Solid edge lamp shield Increased maintenance convenience Most Alter Concept models with microperforated mesh lamp shield include signature Solid Edge finish for aesthetic visual appearance where shield and reflector meet. Tool-free access from below facilitates lamp and ballast replacements. Introducing a combination of functionalities so practical, they could change the way architects design energy efficient buildings. Alter Concept features a generation of low profile luminaires. In addition to offering Alter hallmark aesthetics in a greener, more compact and more affordable lighting package, these luminaires deliver superior lighting output well suited to meeting sustainability objectives and LEED requirements. Alter Concept Elegance Available in glass and perforated steel shielding models, and in a lens version with fully enclosed dust-free lamp compartment ideal for food preparation areas and hospital applications. Old version Decorative elements Glass versions of Alter Concept Elegance, including style-matched Alter Elegance Glass Wall, integrate richly textured architectural materials, such as frosted ridged glass and natural satinfinished metal. Improved version with Solid-Edge technology and seamless design Alter Concept SR Semi-recessed T5 and T8 versions with microperforated mesh lamp shield. Comprehensive lighting catalog 7th Edition 4.65 Linear recessed and surface lighting – Professional Alter Concept Elegance Perforated 2' x 4', 2' x 2' & 1' x 4' Direct/indirect static shallow T5 recessed luminaires Attractive Concept Elegance provides outstanding lighting design statements in offices and public spaces. This luminaire features seamless construction along with the clean look of solid-edge microperforated mesh lamp shields. It belongs to the Alter Concept collection of sustainable lighting elements, offering cost-effective lighting in a lightweight, low-profile design ideal for shallow plenums, modern interiors and green buildings. Features • Efficiencies up to 67.9%. • Seamless welded form for 2' x 2' and 2' x 4' models: curved top and side reflectors are formed together without any gaps or visual barriers. • Shallow design, only 3 ⅝" deep for easy installation in shallow plenum. QCE2GPFOS228UNVPG 2' x 4' Alter Concept Elegance Perf, 2-Lamp 28W T5 RCR 3 ⅝" 1 (92mm) 3 5 7 10 • Post-painted luminaire. • Solid-Edge swing-down microperforated lamp shield for easy relamping and maintenance. 24" (610mm) • Alter soft white film on inside of mesh conceals lamp image providing balance between reflected and direct light. C.U. 71 55 43 34 25 Candlepower Curve Reference data Efficiency 67.9% Spacing ratio 1.3 Electronic ballast 60˚ 400 Input watts (120V) 65.0W Ballast factor 1.0 800 • Fully recessed luminaire and lamp compartment. • 95% Reflective Alter soft white paint finish. 1200 48" (1220mm) • One-piece body for easy installation. 30˚ • Easy access to ballast through lamp compartment. • Can be row mounted. QCE2GPFOS2FTUNVPR • Fits standard 15/16" T-Grid, Slot T-Grid Options & accessories 2' x 2' Alter Concept Elegance Perf, 2-Lamp 40W TT5 RCR 3 ⅝" (92mm) 1 page 4.72 + 4.130 Ballast: Specify voltage (120, 277 or UNV) and type and add as suffix, e.g. UNVPG. 3 5 7 10 24" (610mm) Ballast type <10THD Electronic T5/T5HO Program start PG Electronic TT5 40W Instant start IB BP Electronic TT5 55W Rapid start BF Electronic (2) T5 28W Step-dim AY Programed Rapid Start (B.F.=0.95/0.35) Electronic TT5/T5/T5HO Program start DALI Digital addressable dimming DA Drywall kit: C onversion kit for 2' x 4' unit: FK92X4. Conversion kit for 2' x 2' unit: FK92X2. Conversion kit for 1' x 4' unit: FK91X4. Hold down clips: Standard T 15/16" only: QVS-HD. Emergency Lighting: Consult factory for options. Fusing: Suffix: A (Internal fast-blow fusing). Suffix: C (Internal slow-blow fusing). 59 46 36 29 22 Candlepower Curve Reference data Efficiency 56.0% Spacing ratio 1.3 Electronic ballast 60˚ 400 Input watts (120V) 68.5W Ballast factor 0.9 800 24" (610mm) Electronic TT5 40W Program rapid start PR Electronic TT5 50W Rapid start C.U. 1200 30˚ Ordering information Recessed ceiling depth Type Size Lamp qty –type Lamp watts Catalog no. Static microperforated mesh lamp shields 2' x 4' 3 ⅝" 2-T5 3-T5 2-T5HO 28W 28W 54W Static microperforated mesh lamp shields 2' x 2' 3 ⅝" 2-TT5 2-T5HO 40, 50, 55W QCE2GPFOS2FT 24W QCE2GPFOS224 Static microperforated mesh lamp shields 1' x 4' 3 ⅝" 1-T5HO 2-T5 2-T5HO 54W 28W 54W QCE2GPFOS228 QCE2GPFOP328* QCE2GPFOS254 QCE1GPFOS154 QCE1GPFOS228 QCE1GPFOS254 Replace OS (open slot) by OP for one piece lamp shield (e.g. QCE2GPFOP2FTUNVIB). * 3-lamp combination only available with one-piece lamp shield. Example QCE2GPFOS2FT UNV IB Alter Concept Elegance Perf Voltage Ballast Direct/indirect recessed UNV= 120-277V See page 4.66 4.66 Philips Lightolier Options See page 4.66 and page 4.72 For complete specification information visit www.lightolier.com Professional – Linear recessed and surface lighting Alter Concept Elegance Lens 2' x 4', 2' x 2' & 1' x 4' Direct/indirect static shallow T5 recessed luminaires The Concept Elegance Lens model takes lighting performance to new levels while delivering Alter’s signature soft lighting effect. It features superior efficiency and seamless construction. It belongs to the Alter Concept collection of sustainable lighting elements, offering costeffective lighting in a lightweight, low-profile design ideal for shallow plenums, modern interiors and green buildings. QCE2GOLOP228UNVPG 2' x 4' Alter Concept Elegance Lens, 2-Lamp 28W T5 RCR 3 ⅝" (92mm) 1 3 5 7 10 24" (610mm) C.U. 96 72 56 45 33 Candlepower Curve Reference data Efficiency 92.7% Spacing ratio 1.4 Electronic ballast 60˚ 500 • Seamless welded form for 2' x 2' and 2' x 4' models: curved top and side reflectors are formed together without any gaps or visual barriers. 1000 1438 48" (1220mm) Features • Efficiencies up to 92.7%. Input watts (120V) 61.5W Ballast factor 1.0 30˚ • Shallow design, only 3 ⅝" deep for easy installation in shallow plenum. • Post-painted luminaire. QCE2GOLOP214UNVPG 2' x 2' Alter Concept Elegance Lens, 2-Lamp 14W T5 RCR 3 ⅝" (92mm) 1 3 5 7 10 24" (610mm) C.U. 83 56 41 32 23 Candlepower Curve Reference data Efficiency 87.6% Spacing ratio 1.4 Electronic ballast 60˚ 250 Input watts (120V) 32.6W Ballast factor 1.0 • Fits standard 15/16" T-Grid, Slot T-Grid or drywall ceilings 30˚ Static etched lens lamp shields 2' x 2' Static etched lens lamp shields 1' x 4' Example Options & accessories page 4.72 + 4.130 Ballast: Specify voltage (120, 277 or UNV) and type and add as suffix, e.g. UNVPG. Ordering information 2' x 4' • One-piece body for easy installation. • Can be row mounted. 750 Static Etched lens lamp shields • 95% Reflective Alter soft white paint finish. • Easy access to ballast through lamp compartment. 24" (610mm) Size • No tools required to remove lens for easy relamping and maintenance. • Fully recessed luminaire and lamp compartment. 500 Type • High performance contoured lens conceals lamp image providing balance between reflected and direct light. Recessed ceiling depth QCE2GOLOP214 3 ⅝" 3 ⅝" 3 ⅝" Lamp qty –type Lamp watts Catalog no. Ballast type <10THD QCE2GOLOP228 QCE2GOLOP254 Electronic T5/T5HO Program start PG Electronic TT5 40W Instant start IB 2-T5 2-T5HO 28W 54W 1-TT5 2-T5 2-T5HO 40, 50, 55W QCE2GOLOP1FT 14W QCE2GOLOP214 24W QCE2GOLOP224 1-T5HO 2-T5 2-T5HO 54W 28W 54W UNV QCE1GOLOP154 QCE1GOLOP228 QCE1GOLOP254 PG Alter Concept Elegance Lens Voltage Ballast Direct/indirect recessed UNV= 120-277V See page 4.67 Options See page 4.67 and page 4.72 Electronic TT5 40W Program rapid start PR Electronic TT5 50W Rapid start BP Electronic TT5 55W Rapid start BF Electronic (2) T5 28W Step-dim AY Programed Rapid Start (B.F.=0.95/0.35) Electronic TT5/T5/T5HO Program start DALI Digital addressable dimming DA Drywall kit: C onversion kit for 2' x 4' unit: FK92X4. Conversion kit for 2' x 2' unit: FK92X2. Conversion kit for 1' x 4' unit: FK91X4. Hold down clips: Standard T 15/16" only: QVS-HD. Emergency Lighting: Consult factory for options. Fusing: Suffix: A (Internal fast-blow fusing). Suffix: C (Internal slow-blow fusing). Comprehensive lighting catalog 7th Edition 4.67 Linear recessed and surface lighting – Professional Alter Concept Elegance Glass 2' x 4' & 2' x 2' Direct/indirect static shallow T5 recessed luminaires Concept Elegance Glass exudes soft lighting presence to bring an air of distinction to architectural decors. This luminaire family features beautifully textured glass panels, seamless construction and includes a 2' x 4' version. It belongs to the Alter Concept collection of sustainable lighting elements, offering cost-effective lighting in a lightweight, low-profile design ideal for shallow plenums, modern interiors and green buildings. QCE2GGLOS228UNVPG 2' x 4' Alter Concept Elegance Perf, 2-Lamp 28W T5 3 ⅝" (92mm) Features • Efficiencies up to 70.7%. 24" (610mm) Efficiency 70.7% Spacing ratio 1.3 Electronic ballast • Seamless welded form: curved top and side reflectors are formed together without any gaps or visual barriers. • Post-painted luminaire. • Elegant ridged glass lamp shields on hinged aluminium extrusions swing down for easy relamping and maintenance. • Fully recessed luminaire and lamp compartment. 48" (1220mm) QCE2GGLOS2FTUNVPR • 95% Reflective Alter soft white paint finish. • Easy access to ballast through lamp compartment. RCR C.U. 1 3 5 7 10 74 58 45 36 27 800 1200 30˚ 2' x 2' Alter Concept Elegance Perf, 2-Lamp 40W TT5 3 ⅝" (92mm) • One-piece body for easy installation. 24" (610mm) Candlepower Curve Reference data Efficiency 58.2% Spacing ratio 1.3 Electronic ballast • Can be row mounted. 60˚ 400 Input watts (120V) 68.9W Ballast factor 0.9 • Fits standard 15/16" T-Grid, Slot T-Grid Options & accessories 60˚ 400 Input watts (120V) 63.0W Ballast factor 1.0 • Shallow design, only 3 ⅝" deep for easy installation in shallow plenum. • Alter soft white film on inside of ridged glass conceals lamp image providing balance between reflected and direct light. Candlepower Curve Reference data page 4.72 + 4.130 Ballast: Specify voltage (120, 277 or UNV) and type and add as suffix, e.g. UNVPG. Ballast type <10THD Electronic T5/T5HO Program start PG Electronic TT5 40W Instant start IB Electronic TT5 40W Program rapid start PR Electronic TT5 50W Rapid start BP Electronic TT5 55W Rapid start BF Electronic (2) T5 28W Step-dim Programed rapid start (B.F.=0.95/0.35) AY Electronic TT5/T5/T5HO Program start DALI Digital addressable dimming DA Drywall kit: C onversion kit for 2' x 4' unit: FK92X4. Conversion kit for 2' x 2' unit: FK92X2. Hold down clips: Standard T 15/16" only: QVS-HD. Emergency Lighting: Consult factory for options. 24" (610mm) RCR C.U. 1 3 5 7 10 61 43 33 26 18 800 1200 30˚ Ordering information Recessed ceiling depth Type Size Static Concept Elegance Glass double glass lamp shields 2' x 4' 3 ⅝" 2-T5 2-T5HO 28W 54W Static Concept Elegance Glass double glass lamp shields 2' x 2' 3 ⅝" 2-TT5 2-T5HO 40, 50, 55W QCE2GGLOS2FT 24W QCE2GGLOS224 Example QCE2GGLOS2FT Lamp qty –type UNV Lamp watts Catalog no. QCE2GGLOS228 QCE2GGLOS254 IB Alter Concept Elegance Perf Voltage Ballast Direct/indirect recessed UNV= 120-277V See page 4.68 Options See page 4.68 and page 4.72 Fusing: Suffix: A (Internal fast-blow fusing). Suffix: C (Internal slow-blow fusing). 4.68 Philips Lightolier For complete specification information visit www.lightolier.com Professional – Linear recessed and surface lighting Alter Elegance Wall 9" x 12" & 9" x 24" Direct/indirect static ceiling & wall luminaires Alter Elegance Wall employs decorative elements in its design such as frosted, ridged glass lenses with natural satin finished trim accents made of satin finished metal. This design brings a unique level of refinement to the world of balanced brightness. Whether installed on walls, columns, partitions or even in alcoves, these luminaires create visual interest in combination with Alter Elegance for example. The utilization of these two products provides opportunities in any space for design consistency. QVW8SGLOS218UNVBA Alter Elegance Wall, 2-Lamp 18W TT5 RCR C.U. 1 3 5 7 10 52 37 28 22 16 Reference data Efficiency 60.9% Electronic ballast Input watts (120V) 65.6W Ballast factor 0.88 1000 Candlepower Curve 135˚ 750 500 250 12 ¼" (311mm) 4" (101mm) 45˚ 9 ¾" (248mm) 24" (610mm) 4" (101mm) 9 ¾" (248mm) Features • Efficiency 60.9%. Ordering information Type Size Static Elegance Wall 9" x 12" 9" x 24" Example Lamp qty –type Lamp watts 18W 40W 2-TT5 QVW8SGLOS2FT Alter Concept Elegance Perf Direct/indirect recessed UNV • Uses mounting surface as part of optical system. Catalog no. QVW8SGLOS218 QVW8SGLOS2FT • Installs vertically or horizontally on wall / ceiling. • Providing balance between reflected and direct light. • 0 degree lamp cut-off. BA Voltage Ballast 120 = 120V See page 4.69 277 = 277V UNV= 120-277V • Available in 12" and 24" options. • One piece body for easy installation. Options See page 4.69 and page 4.72 • Lamp shield constructed of decorative frosted rigid glass and natural satin-finished metal Options & accessories page 4.72 + 4.130 Ballast: Specify voltage (120, 277 or UNV) and type and add as suffix, e.g. UNVIB. Ballast type Electronic 40W TT5 IB 50W TT5 BP 55W TT5 BF 18W TT5 BA PowerSpec HDF dimming 40W TT5 PB Fusing: Suffix: A (Internal fusing). Comprehensive lighting catalog 7th Edition 4.69 Linear recessed and surface lighting – Professional Alter Concept SR T5 2' x 4' & 2' x 2' Direct/indirect static T5 semi recessed luminaires Subtle presence at the ceiling line and classy styling make Concept SR T5 a visually pleasing option for halls, corridors and other spaces. This semi-recessed luminaire features seamless construction along with the clean look of solid-edge microperforated mesh lamp shields. It belongs to the Alter Concept collection of sustainable lighting elements, offering costeffective lighting in a lightweight, low-profile design ideal for shallow plenums, modern interiors and green buildings. QCH2GPFOS228UNVPG 2' x 4' Alter Concept SR T5, 2-Lamp 28W T5 • Efficiencies up to 77.5%. Efficiency 71.4% Spacing ratio 1.3 24" (610mm) • Seamless welded form: curved top and side reflectors are formed together without any gaps or visual barriers. Electronic ballast • Post-painted luminaire. • Solid-edge swing-down microperforated lamp shield for easy relamping and maintenance. • Semi-recessed luminaire and lamp compartment. 48" (1220mm) QCH2GPFOS2FTUNVPR • Easy access to ballast through lamp compartment. • Can be row mounted. 24" (610mm) 24" (610mm) Ballast type <10THD IB Electronic TT5 40W Program rapid start PR Electronic TT5 50W Rapid start BP Electronic TT5 55W Rapid start BF Electronic (2) T5 28W Step-Dim Programed rapid start (B.F.=0.95/0.35) AY Electronic TT5/T5/T5HO Program start DALI Digital addressable dimming DA Drywall kit: C onversion kit for 2' x 4' unit: FK92X4. Conversion kit for 2' x 2' unit: FK92X2. Hold down clips: Standard T 15/16" only: QVS-HD. Emergency Lighting: Consult factory for options. Fusing: Suffix: A (Internal fast-blow fusing). Suffix: C (Internal slow-blow fusing). 4.70 Philips Lightolier 1172 30˚ Candlepower Curve Electronic ballast page 4.72 + 4.130 PG 75 57 45 36 26 60˚ 400 Input watts (120V) 70.7W Ballast factor 0.9 Ballast: Specify voltage (120, 277 or UNV) and type and add as suffix, e.g. UNVIB. Electronic TT5 40W Instant start 1 3 5 7 10 800 Efficiency 58.2% Spacing ratio 1.3 • Fits standard 15/16" T-Grid, Slot T-Grid Electronic T5/T5HO Program start C.U. Reference data 3 ⅝" 5 (92mm) 4 ¹ ¹6" (126mm) • One-piece body for easy installation. RCR 2' x 2' Alter Concept SR T5, 2-Lamp 40W TT5 • 95% Reflective Alter soft white paint finish. Options & accessories 60˚ 400 Input watts (120V) 67.5W Ballast factor 1.0 • Shallow design, only 3 ⅝" deep for easy installation in shallow plenum. • Alter soft white film on inside of mesh conceals lamp image providing balance between reflected and direct light. Candlepower Curve Reference data 3 ⅝" (92mm) 4 ¹5¹6" (126mm) Features RCR C.U. 1 3 5 7 10 61 47 37 30 22 800 1200 30˚ Ordering information Recessed ceiling depth Type Size Lamp qty –type Lamp watts Catalog no. Static Microperforated mesh lamp shields 2' x 4' 3 ⅝" 2-T5 2-T5HO 3-T5HO 28W 54W 28W Static microperforated mesh lamp shields 2' x 2' 3 ⅝" 2-T5 2-T5HO 3-T5HO 40, 50, 55W QCH2GPFOS2FT 24W QCH2GPFOS224 24W QCH2GPFOP324* QCH2GPFOS228 QCH2GPFOS254 QCH2GPFOP328* * 3-lamp combination only available with one-piece lamp shield. Example QCH2GPFOS2FT UNV IB Alter Concept Elegance Perf Voltage Ballast Direct/indirect recessed UNV= 120-277V See page 4.70 Options See page 4.70 and page 4.72 For complete specification information visit www.lightolier.com Professional – Linear recessed and surface lighting Alter Concept SR T8 2' x 4' & 2' x 2' Direct/indirect static T8 semi recessed luminaires Subtle presence at the ceiling line and classy styling make Concept SR T8 a visually pleasing option for halls, corridors and other spaces. This semi-recessed luminaire features T8 affordability and seamless construction, along with the clean look of microperforated mesh lamp shields. It belongs to the Alter Concept collection of sustainable lighting elements, offering cost-effective lighting in a lightweight, low-profile design ideal for shallow plenums, modern interiors and green buildings. QCJ2GPFOP332UNVH3 2' x 4' Alter Concept SR T8, 3-Lamp 32W T8 Candlepower Curve Reference data 3 ⅝" (92mm) 4 ¹5 6" ¹ (126mm) Features Efficiency 70.5% Spacing ratio 1.3 24" (610mm) • Efficiencies up to 70.5%. Electronic ballast 60˚ 600 Input watts (120V) 90.7W Ballast factor 0.88 48" (1220mm) QCJ2GPFOP217UNVHI RCR C.U. 1 3 5 7 10 73 56 44 35 25 • Post-painted luminaire. 1200 • Cost-effective T8 solution with shallow design, only 3 ⅝" deep for easy installation in shallow plenum. 1944 30˚ Candlepower Curve Reference data Efficiency 68.6% Spacing ratio 1.3 24" (610mm) Electronic ballast 60˚ Input watts (120V) 31.2W Ballast factor 0.91 24" (610mm) C.U. 1 3 5 7 10 71 55 43 34 25 Size Static microperforated mesh lamp shields 2' x 4' Static microperforated mesh lamp shields 2' x 2' Recessed ceiling depth Lamp qty –type • 95% Reflective Alter soft white paint finish. • One-piece body for easy installation. • Fits standard 15/16" T-Grid, Slot T-Grid page 4.72 + 4.130 Ballast: Specify voltage (120, 277 or UNV) and type and add as suffix, e.g. UNVHI. 607 Lamp watts • Not suitable for row mounting. Options & accessories 400 30˚ Ballast type <10THD Ordering information Type • Semi-recessed luminaire and lamp compartment. • Easy access to ballast through lamp compartment. 200 RCR • One-piece swing-down microperforated lamp shield for easy relamping and maintenance. • Alter soft white film on inside of mesh conceals lamp image providing balance between reflected and direct light. 2' x 2' Alter Concept SR T8, 2-Lamp 17W T8 3 ⅝" (92mm) 4 ¹5 6" ¹ (126mm) • Seamless welded form: curved top and side reflectors are formed together without any gaps or visual barriers. Catalog no. 3 ⅝" 2-T8 3-T8 32W 32W QCJ2GPFOP232 QCJ2GPFOP332 3 ⅝" 2-T8 17W QCJ2GPFOP217 Electronic T8 Program start P2 Electronic T8 Instant start HI Electronic T8 3-lamp instant start H3 Electronic T8 Program start DALI Digital addressable dimming DA Drywall kit: C onversion kit for 2' x 4' unit: FK92X4. Conversion kit for 2' x 2' unit: FK92X2. Hold down clips: Standard T 15/16" only: QVS-HD. Emergency Lighting: Consult factory for options. Example QCJ2GPFOP217 UNV Fusing: Suffix: A (Internal fast-blow fusing). Suffix: C (Internal slow-blow fusing). HI Alter Concept Elegance Perf Voltage Ballast Direct/indirect recessed UNV= 120-277V See page 4.71 Options See page 4.71 and page 4.72 Comprehensive lighting catalog 7th Edition 4.71 Linear recessed and surface lighting – Professional Alter Options & accessories Liteguard Liteguard is a lens for recessed luminaires adding protection against pathogens, dust and bugs and makes cleaning easy. It fits on almost all 2' x 2', 2' x 4' and 1' x 4' fully recessed luminaires including troffers, parabolics and Alter-types. Post-painted matte white aluminum frame fits Alter paint. Clear Acrylic Lens GI = ⅛" nominal thickness Clear Polycarbonate Lens PX = ⅛" nominal thickness Example LG Family LG = Liteguard 2X2 GI Luminaire Nominal size 2X2 = 2' x 2' 2X4 = 2' x 4' 1X4 = 1' x 4' Lens GI = Clear Acrylic PX = Clear Polycarbonate See Liteguard brochure for more details. Available for: Alter Classic Recessed 2' x 2'. . . . . . . (not avail. with air handling) Alter Classic Recessed 2' x 4'. . . . . . . (not avail. with air handling) Alter Classic Recessed 1' x 4'. . . . . . . (not avail. for 1 lamp) Alter Slim Semi-recessed 2' x 2'. . . . . (not avail. for 1 lamp) Alter Slim Semi-recessed 2’ x 4’. . . . . (not avail. for 2-lamp TT5) Alter Slim Square 2' x 2'. . . . . . . . . . . . (not avail. for 1 lamp) Alter Slim Surface 2' x 2', 2’ x 4’. . . . . (not avail. for 2-TT5) Optional clear polished acrylic drop-down visual element with projected color face Substitute acrylic suffix in place of open slot (OS) only. (e.g. replace QVS2GPFOS by QVS2GPFGR (Red) Suffix: GC (Clear) GG (Green Acrylic) GB (Blue) GR (Red Acrylic) For other colors, consult your Philips Lightolier representative. Size Example Description Catalog no. 1' x 4' 2' x 2' 2' x 4' LNQVS14 LNQVS22 LNQVS24 (Color Suffix) (Color Suffix) (Color Suffix) LNQVS14 - GB LNQVS22 - GR LNQVS24 - GG Emergency power battery pack Hold down clips Radio interference filter Internal fusing Add appropriate suffix in option box: T8/T5/T5HO models. Suffix: E Four clips required per luminaire. Suited to standard 15/16" and slot T grid ceilings. Can also be used for row-mounting applications. Suffix: R (in Option box) Suffix: A (Internal fast-blow fusing). Suffix: C (Internal slow-blow fusing). Factory installed emergency power battery pack with charger and inverter, concealed in luminaire channel. Upon loss of AC power, operates one fluorescent lamp at 15% light output for 90 minutes. 120V and 277V versions available. Note: 2' x 2' Alter Concept luminaires equipped with Emergency Lighting are 5-1/4" deep. 2' x 4' versions with double-switching are 5-1/4" deep while regular 2' x 4' versions (1 ballast) are 3-5/8" deep. 4.72 To get a lens separately, order Catalog no. Philips Lightolier Order separately: catalog no. QVS-HD. Inductive capacitor circuit designed to minimize interference from line radiation or feedback. (One per circuit required) (Kit bag contains 4 clips) For complete specification information visit www.lightolier.com Linear recessed and surface lighting – Specification Coffaire HP 2' x 4' Direct/indirect recessed static luminaires Our new high-performance Coffaire HP luminaire features a high 95% reflectance white powder painted body, our new Transoptix lens and a 95% reflectance Miro® aluminum reflector. Achieving efficiencies 20% greater than comparable luminaires currently available in the market. CFS2GHP228120WA 5" (127mm) Features • Direct/indirect lamp shield appearance with soft contoured interior. Candlepower Curve Reference data Efficiency 80.2% Spacing ratio 1.3 Electronic ballast • Perforated mesh lamp basket with unique TransOptix lens. Ordering Spotlightinformation Fixture: CFS2GHP228120WA • Body 95% reflective flat white powder coated. Type • 95% Internal Miro® reflector. • 73.4% efficient two lamp 32W T8 2' x 4' luminaire. Static Size Lamp qty –type 2-T5 3-T5 2' x 4' 60˚ 500 Input watts (120V) 56.6W Ballast factor 0.93 24" (610mm) 1000 Lamp watts Catalog no. CFS2GHP228 CFS2GHP328 28W 1500 30˚ • 66.9% efficient three lamp 32W T8 2' x 4' luminaire. • 80.2% efficient two lamp 28W T5 2' x 4' luminaire. • 80.7% efficient two lamp 54W T5HO 2' x 4' luminaire. • Only 5" deep. • Tension screws secure ends to body. • Same fixture fits both G and T ceiling. Example CFS2GHP228 5" 120(127mm) WA Coffaire HP Voltage 24" (610mm) Direct/indirect recessed 120 = 120V w/perforated mesh shield 277 = 277V Fixture: CFS2GHP228120WA UNV= 120-277V CFS2GHP254UNVPG Spotlight Ballast See page 4.74 A Options See page 4.74 and page 4.130 • Fits flush to face of slot grid (T) ceiling. • Injection molded light stop at basket ends. CFS2GHP254UNVPG • Perforated lamp shield hinges from either side. 5" (127mm) • Can be continuous row mounted. Efficiency 80.7% Spacing ratio 1.3 Electronic ballast • Wiring access plate standard. Ordering CFS2GHP232UNVHI CFS2GHP254UNVPG Spotlightinformation Fixture: CFS2GHP228120WA page 4.130 Type Ballast: Specify voltage (120, 277 or UNV) and type and add as suffix, e.g. UNVHI. Ballast type <10THD <20THD Electronic T8 HI*, P2** SO* 1 - 3 Lamp T8 H3*, P3** O3* Electronic T5 PG – LOL Dimming T8 PS – Static Example Size 2' x 4' Lamp qty –type 1-T5HO 2-T5HO CFS2GHP254 60˚ 800 Input watts (120V) 121.1W Ballast factor 1 24" (610mm) • Construction to meet NYC Code or Chicago Plenum requirement available. Options & accessories Candlepower Curve Reference data • Ballast accessible thru lamp compartment from room side. 1600 Lamp watts Catalog no. CFS2GHP154 CFS2GHP254 54W 5" UNV (127mm) PG Coffaire HP Voltage 24" (610mm) Direct/indirect recessed 120 = 120V w/perforated mesh shield 277 = 277V Fixture: CFS2GHP254UNVPG UNV= 120-277V CFS2GHP232UNVHI Spotlight Ballast See page 4.74 2400 30˚ A Options See page 4.74 and page 4.130 * Instant start. ** Program start. CFS2GHP232UNVHI 5" (127mm) Emergency/wiring options: For special wiring, fusing, electronic dimming ballasts, consult factory. Ordering Spotlightinformation Fixture: CFS2GHP232UNVHI Static Example Size 2' x 4' Lamp qty –type 2-T8 3-T8 CFS2GHP232 Coffaire HP Direct/indirect recessed w/perforated mesh shield Philips Lightolier 60˚ 1100 Lamp watts 32W 550 Input watts (120V) 58.7W Ballast factor 0.88 24" (610mm) Type 4.74 Efficiency 73.4% Spacing ratio 1.3 Electronic ballast Packaging: Individual carton is standard. Fusing: Suffix: A (Internal fast-blow fusing). Suffix: C (Internal slow-blow fusing). Candlepower Curve Reference data Drywall kit: Conversion kit for 2' x 4' unit: FK92X4. Catalog no. CFS2GHP232 CFS2GHP332 UNV HI Voltage 120 = 120V 277 = 277V UNV= 120-277V Ballast See page 4.74 1650 30˚ A Options See page 4.74 and page 4.130 For complete specification information visit www.lightolier.com Specification – Linear recessed and surface lighting Coffaire HP 2' x 2' Direct/indirect recessed static luminaires Our new high-performance Coffaire HP luminaire features a high 95% reflectance white powder painted body, our new Transoptix lens and a 95% reflectance Miro® aluminum reflector. Achieving efficiencies 20% greater than comparable luminaires currently available in the market. The 2' x 2' model, with Philips ballast and 25 watt PL-L lamps, is over 85% efficient. This unique combination of the Coffaire HP, lamps and ballast provides 46 maintained foot candles at 0.71 watts per square foot. CFS2GHP224UNVPG Candlepower Curve Reference data 5" (127mm) Efficiency 76.6% Spacing ratio 1.4 • Direct/indirect lamp shield appearance with soft contoured interior. Electronic ballast Ordering information Spotlight Fixture: CFS2GPF224UNVPG Type Static Example Size Lamp qty –type 2' x 2' CFS2GHP224 14W 24W 24W 5" (127mm) 5" (127mm) • 76.6% efficient two lamp 24W T5HO 2' x 2' luminaire. CFS2GHP214 CFS2GHP224 CFS2GHP324 PG Coffaire HP Voltage Ballast 24" (610mm) Direct/indirect recessed 120 = 120V See page 4.75 w/perforated mesh shield 277 = 277V CFS2GHP2FTUNVIB ~ 120-277V 25 Watt Lamps Spotlight Fixture: CFS2GPF224UNVPG UNV= (Elec. T8 Ballast only) CFS2GHP2FTUNVIB 900 24" (610mm) Input watts (120V) 57.3W 0.88 Static Example 2' x 2' Lamp qty –type Lamp watts 40W 25W 2-Twin tube T5 CFS2GHP2FT IB 550 Ordering information Spotlight Fixture: CFS2GPF217UNVHI Size Static 2' x 2' Example Lamp qty –type 2-T8 3-T8 CFS2GHP217 Coffaire HP Direct/indirect recessed w/perforated mesh shield 60˚ • Can be continuous row mounted. 1650 • Construction to meet NYC Code or Chicago Plenum requirement available. Options & accessories 1100 page 4.130 Ballast: Specify voltage (120, 277 or UNV) and type and add as suffix, e.g. UNVHI. 30˚ Ballast type <10THD <20THD A Options See page 4.75 and page 4.130 Electronic T8 HI*, P2** SO* 1 - 3 Lamp T8 H3*, P3** O3* Electronic TT5 40W IB*, PR** SB* Electronic T5 PG – * Instant start. ** Program start. Candlepower Curve Drywall kit: Conversion kit for 2' x 2' unit: FK92X2. Emergency/wiring options: For special wiring, fusing, electronic dimming ballasts, consult factory. Efficiency 72.5% Spacing ratio 1.3 250 60˚ Packaging: Individual carton is standard. Fusing: Suffix: A (Internal fast-blow fusing). Suffix: C (Internal slow-blow fusing). Input watts (120V) 30.1W Ballast factor 0.91 24" (610mm) • Ballast accessible thru lamp compartment from room side. • Wiring access plate standard. Electronic ballast Type • Injection molded light stop at basket ends. Candlepower Curve Reference data 5" (127mm) • Fits flush to face of slot grid (T) ceiling. • Perforated lamp shield hinges from either side. CFS2GHP2FT CFS2GHP2FT Coffaire HP Voltage Ballast 24" (610mm) Direct/indirect recessed 120 = 120V See page 4.75 24" (610mm) w/perforated mesh shield 277 = 277V Spotlight ~ 120-277V 25 Watt Lamps Fixture: CFS2GHP2FTUNVIB UNV= Spotlight Fixture: CFS2GPF217UNVHI (Elec. T8 Ballast only) CFS2GHP217UNVHI • Same fixture fits both G and T ceiling. Catalog no. 5" (127mm) UNV 5" (127mm) • 71.5% efficient two lamp 40W TT5 2' x 2' luminaire. • Tension screws secure ends to body. Options See page 4.75 and page 4.130 Efficiency 85.4% Spacing ratio 1.3 Electronic ballast • 85.4% efficient two lamp 25W TT5 2' x 2' luminaire. • Only 5" deep. A Reference data - 25W 24" (610mm) Size 30˚ • 72.5% efficient two lamp 17W T8 2' x 2' luminaire. Ballast factor Spotlight Fixture: CFS2GPF224UNVPG Ordering information CFS2GPF217UNVHI ~ 25 Watt Lamps Spotlight Fixture: CFS2GHP2FTUNVIB Type • 95% Internal Miro® reflector. Catalog no. 5" (127mm) UNV • Perforated mesh lamp basket with unique TransOptix lens. • Body 95% reflective flat white powder coated. 600 Lamp watts 2-T5 2-T5HO 3-T5HO 60˚ 300 Input watts (120V) 52.8W Ballast factor 1 24" (610mm) Features 500 Lamp watts 17W Catalog no. CFS2GHP217 CFS2GHP317 UNV Voltage 120 = 120V 277 = 277V UNV= 120-277V HI Ballast See page 4.75 750 30˚ A Options See page 4.75 and page 4.130 (Elec. T8 Ballast only) Comprehensive lighting catalog 7th Edition 4.75 Linear recessed and surface lighting – Specification Coffaire HP 1' x 4' Direct/indirect recessed static luminaires Our new high-performance Coffaire HP luminaire features a high 95% reflectance white powder painted body, our new Transoptix lens and a 95% reflectance Miro® aluminum reflector. Achieving efficiencies 20% greater than comparable luminaires currently available in the market. CFS1GHP232UNVHI Features Efficiency 69.1% Spacing ratio 1.2 4 1516" (125mm) • Direct/indirect lamp shield appearance with soft contoured interior. Candlepower Curve Reference data Electronic ballast 60˚ 550 Input watts (120V) 57.4W Ballast factor .88 • Perforated mesh lamp basket with unique TransOptix lens. 11⅞" (302mm) 1100 • Body 95% reflective flat white powder coated. • 95% Internal Miro® reflector. • 69.1% efficient two lamp 32W T8 1' x 4' luminaire. • 77.4% efficient two lamp 28W T5 1' x 4' luminaire. • Only 5" deep. Ordering information Spotlight Fixture: CFS1GHP232UNVHI Type Size Static 1' x 4' Lamp qty –type 1-T8 2-T8 • Tension screws secure ends to body. • Same fixture fits both G and T ceiling. Example • Fits flush to face of slot grid (T) ceiling. • Injection molded light stop at basket ends. • Ballast accessible thru lamp compartment from room side. • Wiring access plate standard. 4 1516" (125mm) 4 1516" UNV (125mm) HI Voltage 120 = 120V 277 = 277V UNV= 120-277V Ballast See page 4.76 A Options See page 4.76 and page 4.130 (Elec. T8 Ballast only) CFS1GHP228120WA • Construction to meet NYC Code or Chicago Plenum requirement available. P2** – Electronic T8 (1 & 2 Lamp) HI* SO* Electronic T5 28W (1-2 Lamp) PG** – Electronic T5 54W (1-2 Lamp) PG** – Electronic T5 28W instant start WA*† – LOL Dimming T8 † PS – 57.5 Input watts 0.93 B.F. Other dimming options. Consult factory. Note: For T8 UNV, you must use HI or P2 ballast code. Drywall kit: Conversion kit for 1' x 4' unit: FK91X4. Electronic ballast 550 11⅞" (302mm) 60˚ 1100 Ordering information Spotlight Fixture: CFS1GHP228120WA Type Size Static 1' x 4' * Instant start. Standard (WA Ballast only available in either 120 or 277.) ** Program rapid start (UNV only) Efficiency 77.4% Spacing ratio 1.2 Input watts (120V) 55.4W Ballast factor .93 Ballast type <10THD <20THD Electronic T8 Candlepower Curve Reference data 4 1516" (125mm) page 4.130 Ballast: Specify voltage (120, 277 or UNV) and type and add as suffix, e.g. UNVHI. † 30˚ Spotlight Fixture: CFS1GHP232UNVHI Spotlight Fixture: CFS1GHP228120WA • Can be continuous row mounted. Options & accessories CFS1GHP232 1650 Catalog no. CFS1GHP132 CFS1GHP232 32W Coffaire HP 11⅞" (302mm) recessed Direct/indirect w/perforated 11⅞" (302mm) mesh shield • Perforated lamp shield hinges from either side. Lamp watts Example Lamp qty –type 1-T5 2-T5 1-T5HO 2-T5HO CFS1GHP228 Coffaire HP Direct/indirect recessed w/perforated mesh shield Lamp watts 28W 28W 54W 54W 1650 30˚ Catalog no. CFS1GHP128 CFS1GHP228 CFS1GHP154 CFS1GHP254 120 WA Voltage 120 = 120V 277 = 277V UNV= 120-277V Ballast See page 4.76 A Options See page 4.76 and page 4.130 (Elec. T8 Ballast only) Emergency/wiring options: For special wiring, fusing, electronic dimming ballasts, consult factory. Packaging: Individual carton is standard. Fusing: Suffix: A (Internal fast-blow fusing). Suffix: C (Internal slow-blow fusing). 4.76 Philips Lightolier For complete specification information visit www.lightolier.com Specification – Linear recessed and surface lighting Coffaire II 2' x 4' Direct/indirect recessed air return or static luminaires Coffaire II combines a perforated mesh lamp shields and an indirect cove to create an aesthetically pleasing direct/indirect luminaire that has provision for air return or static operation. CFH2GPF332UNVH3 Candlepower Curve Reference data 5" (127mm) Features Efficiency 60.2% Spacing ratio 1.3 Electronic ballast Ordering information 1100 Type Size Lamp qty –type Static 2' x 4' 3-T8 CFS2GPF332 Air return 2' x 4' 3-T8 CFH2GPF332 CFH2GPF332 Coffaire Direct/indirect recessed w/perforated mesh shield • 63.8% efficient two lamp T8 2' x 4' luminaire. UNV 1650 H3 Voltage 120 = 120V 277 = 277V UNV= 120-277V Ballast See page 4.77 Size 2' x 4' 2-T8 CFS2GPF232 Air return 2' x 4' 2-T8 CFH2GPF232 Ballast See page 4.77 • Housing is available in 20 gauge steel that meets NYC requirements. Options & accessories 30˚ A page 4.130 Ballast type <10THD <20THD Electronic T8 HI*, P2** SO* 1 - 3 Lamp T8 H3*, P3** O3* Electronic T5 Options See page 4.77 and page 4.130 PG – * Instant start. ** Program start. Drywall kit: Conversion kit for 2' x 4' unit: FK92X4. Candlepower Curve Reference data 5" (127mm) • Wiring access plate standard. Ballast: Specify voltage (120, 277 or UNV) and type and add as suffix, e.g. UNVHI. 1050 HI Voltage 120 = 120V 277 = 277V UNV= 120-277V CFS2GPF254UNVPG Efficiency 70.8% Spacing ratio 1.3 Electronic ballast 700 60˚ Emergency/wiring options: For special wiring, fusing, electronic dimming ballasts, consult factory. Packaging: Individual carton is standard. Fusing: Suffix: A (Internal fast-blow fusing). Suffix: C (Internal slow-blow fusing). Input watts (120V) 123.2W Ballast factor 1.0 24" (610mm) 1400 Ordering information Example 60˚ 350 Catalog no. UNV • Can be continuous row mounted. • Built in earthquake clips standard. 700 Static 2' x 4' • Light traps between basket and fixture end (static models). Efficiency 63.8% Spacing ratio 1.4 Type Static • Air return standard (meets UL requirements). Candlepower Curve Ordering information Size • End securing tension bars. Input watts (120V) 58W Ballast factor 0.88 Coffaire Direct/indirect recessed w/perforated mesh shield • Only 5" deep. • Fits flush to face of slot grid T ceiling. Options See page 4.77 and page 4.130 Reference data 24" (610mm) CFH2GPF232 • 70.8% efficient two lamp T5 2' x 4' luminaire. • Same fixture fits both G and T ceiling types. A Electronic ballast Type 30˚ • Lamp shield hinges from either side. 5" (127mm) Example • 60.2% efficient three lamp T8 2' x 4' luminaire. Catalog no. CFH2GPF232UNVHI Lamp qty –type • Direct/indirect lamp shield appearance with soft contoured interior one piece body. • Perforated Mesh Lamp Shields with white acrylic overlay. Input watts (120V) 89W Ballast factor 0.90 24" (610mm) Example 60˚ 550 Lamp qty –type 1-T5HO 2-T5HO 2-T5 CFS2GPF254 Coffaire Direct/indirect recessed w/perforated mesh shield Catalog no. 2100 CFS2GPF154 CFS2GPF254 CFS2GPF228 UNV Voltage 120 = 120V 277 = 277V UNV= 120-277V PG Ballast See page 4.77 30˚ A Options See page 4.77 and page 4.130 Comprehensive lighting catalog 7th Edition 4.77 Linear recessed and surface lighting – Specification Coffaire II 2' x 2' Direct/indirect recessed air return or static luminaires Coffaire II combines a perforated mesh lamp shields and an indirect cove to create an aesthetically pleasing direct/indirect luminaire that has provision for air return or static operation. CFH2GPF2FT120SB 5" (127mm) • Direct/indirect lamp shield appearance with soft contoured interior one piece body. • 56.7% efficient two lamp T5HO 2' x 2' luminaire. • Only 5" deep. • Same fixture fits both G and T ceiling types. • Fits flush to face of slot grid T ceiling. • End securing tension bars. Type Size Static 2' x 2' 2-TT5 CFS2GPF2FT Air return 2' x 2' 2-TT5 CFH2GPF2FT Example • Light traps between basket and fixture end (static models). 800 Ordering information • Air return standard (meets UL requirements). Lamp qty –type CFH2GPF2FT Coffaire Direct/indirect recessed w/perforated mesh shield • Lamp shield hinges from either side. • Can be continuous row mounted. • Wiring access plate standard. • Built in earthquake clips standard. • Housing is available in 20 gauge steel that meets NYC requirements. Catalog no. 120 page 4.130 Voltage 120 = 120V 277 = 277V UNV= 120-277V SO* Ordering information 1 - 3 Lamp T8 H3*, P3** O3* Type Electronic TT5 40W IB*, PR** SB* Size Emergency/wiring options: For special wiring, fusing, electronic dimming ballasts, consult factory. Packaging: Individual carton is standard. Options See page 4.78 and page 4.130 Candlepower Curve Efficiency 56.7% Spacing ratio 1.3 Static 2' x 2' Air return 2' x 2' 2-T8 3-T8 CFS2GPF224 Coffaire Direct/indirect recessed w/perforated mesh shield Fusing: Suffix: A (Internal fast-blow fusing). Suffix: C (Internal slow-blow fusing). 60˚ 600 2-T8 3-T8 2-T5 2-T5HO Example 300 Input watts (120V) 56.1W Ballast factor Lamp qty –type * Instant start. ** Program start. Drywall kit: Conversion kit for 2' x 2' unit: FK92X2. Ballast See page 4.78 Electronic ballast Ballast type <10THD <20THD PG – A Reference data 24" (610mm) HI*, P2** 30˚ (Elec. TT5 Ballast only) 5" (127mm) Ballast: Specify voltage (120, 277 or UNV) and type and add as suffix, e.g. UNVHI. 1200 SB CFS2GPF224UNVPG Electronic T8 60˚ 400 Input watts (120V) 65.5W Ballast factor 0.90 24" (610mm) • 68.10% efficient two lamp TT5 2' x 2' luminaire. Electronic T5 Efficiency 68.1% Spacing ratio 1.4 Electronic ballast • Perforated mesh lamp shields with white acrylic overlay. Options & accessories Candlepower Curve Reference data Features Catalog no. CFS2GPF217 CFS2GPF317 CFS2GPF214 CFS2GPF224 CFH2GPF217 CFH2GPF317 UNV 900 PG Voltage 120 = 120V 277 = 277V UNV= 120-277V 30˚ A Ballast See page 4.78 Options See page 4.78 and page 4.130 Mounting methods Exposed T-grid ceiling Exposed slot T-grid ceiling Exposed T-bar by others Exposed T-bar by others 1 ½" max. 1 ½" max. Acoustical material by others Acoustical material by others 9/16" 15/16" 24" 4.78 Philips Lightolier 24" Meets fire test requirement of UL 1598 For complete specification information visit www.lightolier.com Specification – Linear recessed and surface lighting Coffaire II 1' x 4' Direct/indirect recessed air return or static luminaires Coffaire II combines a perforated mesh lamp shields and an indirect cove to create an aesthetically pleasing direct/indirect luminaire that has provision for air return or static operation. CFH1GPF232UNVHI Candlepower Curve Reference data Efficiency 52.1% Spacing ratio 1.2 5" (127mm) Features Electronic ballast 60˚ 400 Input watts (120V) 67.7W Ballast factor 0.87 12" (305mm) Air return Static Example Size • Perforated mesh lamp shields with white acrylic overlay. 800 • 52.1% efficient two lamp T8 1' x 4' luminaire. • 55.7% efficient two lamp T5 1' x 4' luminaire. Ordering information Type Lamp qty –type 1' x 4' 1-T8 2-T8 1' x 4' 1-T8 2-T8 CFH1GPF232 Lamp watts 1200 Catalog no. 30˚ • Fits flush to face of slot grid T ceiling. 32W CFS1GPF132 CFS1GPF232 • Lamp shield hinges from either side. HI Voltage 120 = 120V 277 = 277V UNV= 120-277V Ballast See page 4.79 • Air return standard (meets UL requirements). • Can be continuous row mounted. • Wiring access plate standard. A • 2 earthquake clips standard. • Housing is available in 20 gauge steel that meets NYC requirements. Options See page 4.79 and page 4.130 • Construction to meet Chicago Plenum requirements is available. (Elec. T8 Ballast only) Options & accessories Candlepower Curve Reference data Efficiency 55.7% Spacing ratio 1.2 5" (127mm) Electronic ballast 400 12" (305mm) 60˚ 800 Ordering information Air return Static Example 1' x 4' 1' x 4' Lamp watts 28W 28W 54W 54W CFH1GPF128 CFH1GPF228 CFH1GPF154 CFH1GPF254 1-T5 2-T5 1-T5HO 2-T5HO 28W 28W 54W 54W CFS1GPF128 CFS1GPF228 CFS1GPF154 CFS1GPF254 CFH1GPF228 Coffaire Direct/indirect recessed w/perforated mesh shield 1200 Catalog no. 1-T5 2-T5 1-T5HO 2-T5HO 120 Voltage 120 = 120V 277 = 277V UNV= 120-277V WA Ballast See page 4.79 page 4.130 Ballast: Specify voltage (120, 277 or UNV) and type and add as suffix, e.g. UNVHI. Ballast type <10THD <20THD Input watts (120V) 57.0W Ballast factor 0.93 Lamp qty –type • Same fixture fits both G and T ceiling types. 32W CFH1GPF228120WA Size • Only 5" deep. CFH1GPF132 CFH1GPF232 UNV Coffaire Direct/indirect recessed w/perforated mesh shield Type • Direct/indirect lamp shield appearance with soft contoured interior. 30˚ Electronic T8 P2** – Electronic T8 (1 & 2 Lamp) HI* SO* Electronic T5 28W (1-2 Lamp) PG** – Electronic T5 54W (1-2 Lamp) PG** – Electronic T5 28W instant start WA*† – LOL Dimming T8 PS – * Instant start. Standard (WA Ballast only available in either 120 or 277.) ** Program rapid start (UNV only) † 57.5 Input watts 0.93 B.F. Other dimming options. Consult factory. Note: For T8 UNV, you must use HI or P2 ballast code. Drywall kit: Conversion kit for 1' x 4' unit: FK91X4. A Options See page 4.79 and page 4.130 Emergency/wiring options: For special wiring, fusing, electronic dimming ballasts, consult factory. Packaging: Individual carton is standard. Fusing: Suffix: A (Internal fast-blow fusing). Suffix: C (Internal slow-blow fusing). Comprehensive lighting catalog 7th Edition 4.79 Linear recessed and surface lighting – Specification Coffaire II Air 2' x 4' Direct/indirect recessed air supply and return luminaires Coffaire II Air combines our traditional soft light perforated basket appearance with air supply/return functions for installations that demand both features. CFA2GPF254UNVPG Features • Direct/indirect lamp shield appearance with soft contoured interior. • Contoured body and ends. Type • Air return slots located above lamp shield. • Air return models meet UL 1598, Paragraph 9.2.2.5 requirements. Air supply and return • 65.0% efficient two lamp 28W T5 2' x 4' luminaire. • 70.8% efficient two lamp 54W T5 2' x 4' luminaire. Size Example • 63.8% efficient two lamp T8 2' x 4' luminaire. 1400 Lamp qty –type 2' x 4' CFA2GPF254 • Only 5" deep. • Tension screws secure ends to body. • Perforated lamp shield hinges from either side. Catalog no. UNV PG Voltage 120 = 120V 277 = 277V UNV= 120-277V CFA2GPF232UNVHI • Can be continuous row mounted. Ballast See page 4.80 • Ballast accessible from room side. 5" (127mm) • Optional supply air slot cover. Options See page 4.80 and page 4.130 Candlepower Curve Efficiency 63.8% Spacing ratio 1.4 Electronic ballast • Meets NYC Code. • Construction to meet Chicago Plenum requirements is available. Options & accessories page 4.130 Type Size 2' x 4' Ballast type <10THD <20THD Example Electronic T8 HI*, P2** 1 - 3 Lamp T8 H3*, P3** O3* Electronic T5 PG SO* * Instant start. Drywall kit: Conversion kit for 2' x 4' unit: FK92X4. Lamp qty –type CFA2GPF232 UNV HI Voltage 120 = 120V 277 = 277V UNV= 120-277V CFA2GPF332UNVH3 1200 Ballast See page 4.80 5" (127mm) Dust Shield: See folio number: OA50-20. A Candlepower Curve Efficiency 60.2% Spacing ratio 1.3 Electronic ballast Optional supply air slot cover: Order Cat No: CACS-4 CSP. 600 1200 Ordering information Type Size 2' x 4' Example 60˚ Input watts (120V) 85W Ballast factor .88 24" (610mm) Air supply and return 30˚ Options See page 4.80 and page 4.130 Reference data Electrical wiring options: Consult factory. Fusing: Suffix: A (Internal fast-blow fusing). Suffix: C (Internal slow-blow fusing). Catalog no. CFA2GPF232 2-T8 Coffaire II Air Direct/indirect recessed air supply and return w/perforated mesh shield – ** Program start. 800 Ordering information Air supply and return 60˚ 400 Input watts (120V) 58W Ballast factor .87 24" (610mm) Ballast: Specify voltage (120, 277 or UNV) and type and add as suffix, e.g. UNVHI. 30˚ A Reference data • Built-in earthquake clips. Lamp qty –type CFA2GPF332 Coffaire II Air Direct/indirect recessed air supply and return w/perforated mesh shield Philips Lightolier 2100 CFA2GPF254 CFA2GPF228 2-T5 Coffaire II Air Direct/indirect recessed air supply and return w/perforated mesh shield • 60.2% efficient three lamp T8 2' x 4' luminaire. 60˚ 700 Input watts (120V) 123W Ballast factor 1.0 Ordering information • air supply and return. 4.80 Efficiency 70.8% Spacing ratio 1.3 Electronic ballast 24" (610mm) • Perforated mesh lamp shields with white acrylic overlay. Chicago Plenum: Suffix: C. Candlepower Curve Reference data 5" (127mm) 3-T8 Catalog no. 1800 CFA2GPF332 UNV H3 Voltage 120 = 120V 277 = 277V UNV= 120-277V Ballast See page 4.80 30˚ A Options See page 4.80 and page 4.130 For complete specification information visit www.lightolier.com Specification – Linear recessed and surface lighting Coffaire II Air 2' x 2' Direct/indirect recessed air supply and return luminaires Coffaire II Air combines our traditional soft light perforated basket appearance with air supply/return functions for installations that demand both features. CFA2GPF2FT120SB Candlepower Curve Reference data 5" (127mm) Efficiency 68.1% Spacing ratio 1.4 Features Electronic ballast Input watts (120V) 65W Ballast factor .86 24" (610mm) Size Air supply and return 2' x 2' Example Lamp qty –type CFA2GPF2FT 120 Coffaire II Air Direct/indirect recessed air supply and return w/perforated mesh shield SB Voltage 120 = 120V 277 = 277V UNV= 120-277V Ballast See page 4.81 1500 Lamp qty –type 2-T8 2-T5 2-T5HO CFA2GPF217 Candlepower Curve Efficiency 61.7% Spacing ratio 1.4 Voltage 120 = 120V 277 = 277V UNV= 120-277V Ballast See page 4.81 • Optional supply air slot cover. • Meets NYC Code. • Construction to meet Chicago Plenum requirements is available. Options & accessories 600 30˚ page 4.130 Ballast: Specify voltage (120, 277 or UNV) and type and add as suffix, e.g. UNVHI. Ballast type <10THD <20THD A Options See page 4.81 and page 4.130 Electronic T8 HI*, P2** 1 - 3 Lamp T8 H3*, P3** O3* Electronic TT5 40W IB*, PR** Electronic T5 SO* SB* PG – * Instant start. Candlepower Curve Reference data 5" (127mm) Dust Shield: See folio number: OA50-20. 300 60˚ Input watts (120V) 46W Ballast factor 1.0 24" (610mm) CFA2GPF317 Coffaire II Air Direct/indirect recessed air supply and return w/perforated mesh shield 3-T8 Chicago Plenum: Suffix: C. Catalog no. 900 CFA2GPF317 UNV Voltage 120 = 120V 277 = 277V UNV= 120-277V H3 Ballast See page 4.81 Optional supply air slot cover: Order Cat No: CACS-2 CSP. Fusing: Suffix: A (Internal fast-blow fusing). Suffix: C (Internal slow-blow fusing). 600 Ordering information Lamp qty –type Drywall kit: Conversion kit for 2' x 2' unit: FK92X2. Electrical wiring options: Consult factory. Efficiency 55.9% Spacing ratio 1.3 Electronic ballast Example • Built-in earthquake clips. ** Program start. CFA2GPF317UNVH3 2' x 4' 60˚ 200 CFA2GPF217 CFA2GPF214 CFA2GPF224 HI • Can be continuous row mounted. • Ballast accessible from room side. Catalog no. UNV Coffaire II Air Direct/indirect recessed air supply and return w/perforated mesh shield Air supply and return • Only 5" deep. 400 2' x 2' Size • 55.9% efficient three lamp T8 2' x 2' luminaire. • Tension screws secure ends to body. Ordering information Type • 61.7% efficient two lamp T8 2' x 2' luminaire. Input watts (120V) 30W Ballast factor .93 24" (610mm) Example • Air return models meet UL 1598, Paragraph 9.2.2.5 requirements. • 55.2% efficient two lamp TT5 2' x 2' luminaire. Options See page 4.81 and page 4.130 Electronic ballast Air supply and return • Air return slots located above lamp shield. • 68.1% efficient two lamp TT5 2' x 2' luminaire. A Reference data 5" (127mm) Size 30˚ • Perforated lamp shield hinges from either side. CFA2GPF217UNVHI Type • Contoured body and ends. • air supply and return. Catalog no. CFA2GPF2FT CFA2GPF3FT 2-TT5 3-TT5 • Direct/indirect lamp shield appearance with soft contoured interior. • Perforated mesh lamp shields with white acrylic overlay. 1000 Ordering information Type 60˚ 500 30˚ A Options See page 4.81 and page 4.130 Comprehensive lighting catalog 7th Edition 4.81 Linear recessed and surface lighting – Specification Coffaire Drop Basket 2' x 4' Direct/indirect recessed static luminaires Coffaire Drop Basket offers T8 and T5 lamp options in a body that is only recessed 2-1/4". The 2-7/16" deep perforated basket creates uniform light distribution that brightens walls and ceilings. Evenly illuminating both horizontal and vertical surfaces, creating a soft, balanced brightness that enhances visual acuity while creating a visual statement on the ceiling line. Features CDS2GPF228UNVPG • Direct/indirect lamp shield appearance with soft contoured interior. • Perforated mesh lamp shields with white acrylic overlay. 4 1116" (119mm) • 60.8% efficient two lamp T8 2' x 4' luminaire. Candlepower Curve Reference data Efficiency 69.9% Spacing ratio 1.3 Electronic ballast • 66.0% efficient three lamp T8 2' x 4' luminaire. 24" (610mm) • 69.9% efficient two lamp 28W T5 2' x 4' luminaire. • 66.4% efficient two lamp 54W T5HO 2' x 4' luminaire. • Only 2-1/4" plenum depth. Ordering information • Same fixture fits both G and T ceiling types. Type • Fits flush to face of slot grid (T) ceiling. Size • Lamp shield hinges from either side. • Wiring access plate standard. • Optional DALI ballast iGEN Technology accepts digital dimming controllers, scene controllers and automatic control devices. Static 2' x 4' 450 60˚ Input watts (120V) 122W Ballast factor 1.0 900 Lamp qty –type 2-T5 3-T5 2-T8 3-T8 1-T5HO 2-T5HO Lamp watts 28W 28W 32W 32W 54W 54W Catalog no. 1350 CDS2GPF228 CDS2GPF328 CDS2GPF232 CDS2GPF332 CDS2GPF154 CDS2GPF254 30˚ • Construction to meet Chicago Plenum available. • Meets NYC Code requirements. Example • Not for continuous row mounting. Options & accessories page 4.130 Ballast: Specify voltage (120, 277 or UNV) and type and add as suffix, e.g. UNVHI. CDS2GPF228 Coffaire Drop Basket Direct/indirect recessed UNV PG Voltage 120 = 120V 277 = 277V UNV= 120-277V Ballast See page 4.82 A Options See page 4.82 and page 4.130 Ballast type <10THD <20THD Electronic T8 HI*, P2** 1 - 3 Lamp T8 H3*, P3** O3* Electronic T5 PG SO* – * Instant start. ** Program start. Drywall kit: Conversion kit for 2' x 4' unit: FK92X4. Electrical wiring options: Consult factory. Fusing: Suffix: A (Internal fast-blow fusing). Suffix: C (Internal slow-blow fusing). Only 2 ¼" Deep 4.82 Philips Lightolier For complete specification information visit www.lightolier.com Specification – Linear recessed and surface lighting Coffaire Drop Basket 2' x 2' Direct/indirect recessed static luminaires Coffaire Drop Basket offers T8 and T5 lamp options in a body that is only recessed 2-1/4". The 2-7/16" deep perforated basket creates uniform light distribution that brightens walls and ceilings. Evenly illuminating both horizontal and vertical surfaces, creating a soft, balanced brightness that enhances visual acuity while creating a visual statement on the ceiling line. Features CDS2GPF214UNVPG Reference data Candlepower Curve Efficiency 62.9% 4 1116" Spacing ratio 1.3 (119mm) • Perforated mesh lamp shields with white acrylic overlay. Electronic ballast 24" (610mm) 180 Static Example Size 2' x 2' 60˚ Input watts (120V) 33W Ballast factor 1.0 Lamp qty –type 2-T5 2-T5HO 2-TT5 2-T8 3-T8 CDS2GPF214 Coffaire Drop Basket Direct/indirect recessed Lamp watts 14W 24W 40W 17W 17W • 62.9% efficient two lamp T5 2' x 2' luminaire. • 62.6% efficient two lamp T5HO 2' x 2' luminaire. • 55.0% efficient two lamp TT5 2' x 2' luminaire. Catalog no. 540 CDS2GPF214 CDS2GPF224 CDS2GPF2FT CDS2GPF217 CDS2GPF317 UNV Voltage 120 = 120V 277 = 277V UNV= 120-277V PG Ballast See page 4.83 • 59.4% efficient two lamp T8 2' x 2' luminaire. • 55.5% efficient three lamp T8 2' x 2' luminaire. 360 Ordering information Type • Direct/indirect lamp shield appearance with soft contoured interior. 30˚ • Only 2-1/4" plenum depth. • Same fixture fits both G and T ceiling types. • Fits flush to face of slot grid (T) ceiling. • Lamp shield hinges from either side. • Wiring access plate standard. A Options See page 4.83 and page 4.130 • Optional DALI ballast iGEN Technology accepts digital dimming controllers, scene controllers and automatic control devices. • Construction to meet Chicago Plenum available. • Meets NYC Code requirements. • Not for continuous row mounting. Options & accessories page 4.130 Ballast: Specify voltage (120, 277 or UNV) and type and add as suffix, e.g. UNVHI. Ballast type <10THD <20THD Electronic T8 HI*, P2** 1 - 3 Lamp T8 H3*, P3** O3* Electronic TT5 40W IB*, PR** Electronic T5 SO* SB* PG – * Instant start. ** Program start. Drywall kit: Conversion kit for 2' x 2' unit: FK92X2. Electrical wiring options: Consult factory. Fusing: Suffix: A (Internal fast-blow fusing). Suffix: C (Internal slow-blow fusing). Comprehensive lighting catalog 7th Edition 4.83 Linear recessed and surface lighting – Specification Coffaire Drop Basket 2' x 4' Direct/indirect surface mounted static luminaires Coffaire Drop Basket ~ Surface Mounted offers T8 and T5 lamp options in a body that is only 2-17/32" deep. The 2-7/16" deep perforated basket creates uniform light distribution that brightens walls and ceilings. Evenly illuminating both horizontal and vertical surfaces, creating a soft, balanced brightness that enhances visual acuity while creating a visual statement on the ceiling line. CDB2SPF232UNVHI Features • Direct/indirect lamp shield appearance with soft contoured interior. 4 " (119mm) • Perforated mesh lamp shields with white acrylic overlay. 24" (610mm) • 69.9% efficient two lamp 28W T5 2' x 4' luminaire. • Optional DALI ballast iGEN Technology accepts digital dimming controllers, scene controllers and automatic control devices. Ordering information • Meets NYC Code requirements. Static page 4.130 Ballast: Specify voltage (120, 277 or UNV) and type and add as suffix, e.g. UNVHI. Type Example HI*, P2** SO* 1 - 3 Lamp T8 H3*, P3** O3* Electronic T5 PG – 800 Lamp qty –type 2' x 4' Lamp watts 24" (610mm) CDB2SPF232 UNV HI Voltage 4 1116" 120 = (119mm) 120V 277 = 277V UNV= 120-277V A Ballast See page 4.84 Options See page 4.84 and page 4.130 Candlepower Curve Reference data 4 1116" (119mm) Efficiency 69.9% Spacing ratio 1.3 Electronic ballast Spotlight Fixture: CFS2GPF224UNVPG Emergency/wiring options: For special wiring, fusing, electronic dimming ballasts, consult factory. 24" (610mm) Static Size 24" (610mm) Example 60˚ Spotligh 900 2 1/4 (57.15mm) Lamp qty –type 2' x 4' 450 Input watts (120V) 122.1W Ballast factor 1 Ordering information Type 30˚ 4 1116" (119mm) 24" (610mm) CDB2SPF228UNVPG ** Program start. Fusing: Suffix: A (Internal fast-blow fusing). Suffix: C (Internal slow-blow fusing). 1200 11 16 * Instant start. Packaging: Individual carton is standard. Catalog no. CDB2SPF232 4 " 32W (119mm) CDB2SPF332 2-T8 3-T8 Coffaire Drop Basket Direct/indirect Surface w/perforated mesh shield 24" (610mm) Ballast type <10THD <20THD Electronic T8 Size 60˚ 400 Input watts (120V) 50.4W Ballast factor 0.88 • Lamp shield hinges from either side. Options & accessories Efficiency 68.0% Spacing ratio 1.3 Electronic ballast • 68.0% efficient two lamp 32W T8 2' x 4' luminaire. • Not for continuous row mounting. Candlepower Curve Reference data 11 16 2-T5 3-T5 24" 1-T5HO 2-T5HO CDB2SPF228 Lamp watts 28W 4 1116" 28W (119mm) (610mm) 54W 54W Catalog no. UNV Coffaire Drop Basket Direct/indirect Surface w/perforated mesh shield 2 7/16 (61.91mm) 1350 CDB2SPF228 CDB2SPF328 CDB2SPF154 CDB2SPF254 PG 30˚ A Voltage Ballast Options Spotlight Fixture: CFS2GPF224UNVPG 120 = 120V See page 4.84 See page 4.84 277 = 277V UNV= 120-277V Spotlight Fixture: CDB2SPF217UNVHI and page 4.130 2 1/4 (57.15mm) Spotligh Spotl 2 7/16 (61.91mm) 2 1/4 (57.15mm) 24" (610mm) 2 7/16 (61.91mm) 24" (610mm) Spotlight Fixture: CDB2SPF217UNVHI 4.84 Philips Lightolier Spotl For complete specification information visit www.lightolier.com 2 1/4 (57.15mm) Specification – Linear recessed and surface lighting Coffaire Drop Basket 2' x 2' Direct/indirect surface mounted static luminaires Coffaire Drop Basket ~ Surface Mounted offers T8 and T5 lamp options in a body that is only 2-17/32" deep. The 2-7/16" deep perforated basket creates uniform light distribution that brightens walls and ceilings. Evenly illuminating both horizontal and vertical surfaces, creating a soft, balanced brightness that enhances visual acuity while creating a visual statement on the ceiling line. CDB2SPF217UNVHI Candlepower Curve Reference data 4 " (119mm) 11 16 Efficiency 59.4% Spacing ratio 1.3 Type Static Example Size Lamp qty –type 24" (610mm) 2' x 2' 60˚ 170 Input watts (120V) 30.8W Ballast factor 0.88 Ordering information 2-T8 3-T8 24" (610mm) CDB2SPF217 4 1116" (119mm) Lamp watts Coffaire Drop Basket Direct/indirect Surface w/perforated mesh shield 24" (610mm) • Lamp shield hinges from either side. Catalog no. 510 CDB2SPF217 4 " 17W (119mm) CDB2SPF317 30˚ 11 16 Ballast See page 4.85 Ballast type <10THD <20THD Candlepower Curve Efficiency 62.9% 4 1116" Spacing ratio 1.3 (119mm) Type Static Example 180 2' x 2' Lamp qty –type Lamp watts 2-T5 14W 2-T5HO 24W 24" 2-Twin tube T5 (610mm) 40W CDB2SPF214 UNV Coffaire Drop Basket Direct/indirect Surface 24" w/perforated mesh shield Voltage (610mm) 120 = 120V 277 = 277V UNV= 120-277V SO* H3*, P3** O3* Electronic TT5 40W IB*, PR** SB* Electronic T5 PG – 2 1/4 (57.15mm) Spotlight Fixture: CDB2SPF228UNVP ** Program start. Packaging: Individual carton is standard. Catalog no. CDB2SPF214 CDB2SPF224 CDB2SPF2FT HI*, P2** 1 - 3 Lamp T8 Emergency/wiring options: For special wiring, fusing, electronic dimming ballasts, consult factory. 360 2 1/4 (57.15mm) 2 7/16 (61.91mm) Spotlight Fixture: CFS2GPF224UNVPG 540 Size 60˚ Input watts (120V) 33.2W Ballast factor 1.06 Ordering information Electronic T8 * Instant start. Spotlight Fixture: CFS2GPF224UNVPG Electronic ballast page 4.130 Ballast: Specify voltage (120, 277 or UNV) and type and add as suffix, e.g. UNVHI. Options See page 4.85 and page 4.130 Reference data 24" (610mm) • Meets NYC Code requirements. Options & accessories A 4 1116" (119mm) 24" (610mm) CDB2SPF214UNVPG • Optional DALI ballast iGEN Technology accepts digital dimming controllers, scene controllers and automatic control devices. • Not for continuous row mounting. HI Voltage 4 1116" 120 = (119mm) 120V 277 = 277V UNV= 120-277V • 59.4% efficient two lamp T8 2' x 2' luminaire. • 62.9% efficient two lamp T5 2' x 2' luminaire. 340 UNV • Direct/indirect lamp shield appearance with soft contoured interior. • Perforated mesh lamp shields with white acrylic overlay. Electronic ballast 24" (610mm) Features 30˚ Spotlight Fixture: CDB2SPF228UNVP 2 Fusing: Suffix: A (Internal fast-blow fusing). Suffix: C (Internal slow-blow fusing). 24" (610mm) 2 7/16 A (61.91mm) PG Ballast See page 4.85 Options See page 4.85 and page 4.130 Spotlight Fixture: CDB2SPF217UNVHI 2 24" (610mm) Spotlight Fixture: CDB2SPF214UN 2 1/4 (57.15mm) Spotlight Fixture: CDB2SPF217UNVHI2 7/16 (61.91mm) 24" (610mm) 2 1/4 (57.15mm) Spotlight Fixture: CDB2SPF214UN 2 24" (610mm) 2 7/16 (61.91mm) 24" (610mm) 2 24" (610mm) Comprehensive lighting catalog 7th Edition 24" (610mm) 4.85 2 Linear recessed and surface lighting – Specification Coffaire SQ 2' x 2' Direct/indirect recessed static luminaires Coffaire SQ offers a white translucent acrylic lens that blends into the reflector paint finish to provide a unique free floating appearance to the attached 10" square perforated mesh steel center panel in an aesthetically pleasing direct/indirect luminaire. CFS2GSQ224UNVPG 5" (127mm) • 75.6% efficient two lamp 24W T5HO 2' x 2' luminaire. 24" (610mm) • 72.7% efficient two lamp 17WT8 2' x 2' luminaire. • Lens hinges from either side of fixture. • Only 5" deep. • Same fixture fits both G and T ceiling types. • Fits flush to face of slot grid (T) ceiling. Efficiency 75.6% Spacing ratio 1.3 5" (127mm) Electronic ballast • 75.2% efficient two lamp 14W T5 2' x 2' luminaire. • Direct/indirect fixture with a softly contoured interior. Candlepower Curve Reference data Features Input watts (120V) 49.8W Ballast factor 1 Ordering information Type Size Static 2' x 2' 700 Lamp qty –type Lamp watts 2-T5 3-T5 2-T5HO 24" 3-T5HO (610mm) • Built-in earthquake clips. 60˚ 350 24" (610mm) Catalog no. CFS2GSQ214 CFS2GSQ314 CFS2GSQ224 CFS2GSQ324 14W 14W 24W 24W 1050 30˚ 24" (610mm) • Can be continuous row mounted. • Wiring access plate standard. Example • Meets NYC Code requirements. • Construction to meet Chicago Plenum requirement is available. Options & accessories page 4.130 Ballast: Specify voltage (120, 277 or UNV) and type and add as suffix, e.g. UNVHI. CFS2GSQ224 UNV Coffaire 24"SQ (610mm) Direct/indirect recessed w/acrylic lens and perforated steel center panel CFS2GSQ217UNVHI (127mm) HI*, P2** SO* 1 - 3 Lamp24" T8 (610mm) H3*, P3** O3* IB*, PR** SB* Electronic TT5 40W Electronic T5 PG – * Instant start. ** Program start. 5" (127mm) (610mm) Candlepower Curve Efficiency 72.7% Spacing ratio 1.3 5" (127mm) Electronic ballast 24" (610mm) Input watts (120V) 30.3W Ballast factor 0.91 Ordering information Type Size Static 2' x 2' Drywall kit: Conversion kit for 24" 2' x 2' unit: FK92X2. Emergency/wiring options: For special wiring, fusing, electronic dimming ballasts, consult factory. A Options 24" (610mm) See page 4.86 and page 4.130 Reference data Ballast type <10THD <20THD 5" Electronic T8 PG Voltage Ballast 120 = 120V See page 4.86 277 = 277V UNV= 120-277V Example 500 Lamp qty –type Lamp watts 2-T8 3-T8 CFS2GSQ217 24" (610mm) Fusing: Suffix: A (Internal fast-blow fusing). 24" (610mm) Suffix: C (Internal slow-blow fusing). Catalog no. CFS2GSQ217 CFS2GSQ317 17W Coffaire SQ Direct/indirect recessed W/acrylic and perforated 24"lens (610mm) steel center panel Packaging: Individual carton is standard. UNV HI Voltage Ballast 120 = 120V See page 4.86 277 = 277V UNV= 120-277V CFS2GSQ2FT120SB 750 5" (127mm) Candlepower Curve Efficiency 71.6% Spacing ratio 1.3 24" (610mm) 24" (610mm) 4.86 Philips Lightolier Size Static 2' x 2' Example 60˚ 1100 Lamp qty –type Lamp watts 2-Twin tube T5 3-Twin tube T5 CFS2GSQ2FT 550 Input watts (120V) 67.0W Ballast factor 0.88 Ordering information Type 24" (610mm) Options See page 4.86 and24" page 4.130 (610mm) Electronic ballast 24" (610mm) 30˚ A Reference data 5" (127mm) 24" (610mm) 60˚ 250 24" (610mm) 24" (610mm) Coffaire SQ Direct/indirect recessed w/acrylic24" lens and perforated (610mm) steel center panel Catalog no. CFS2GSQ2FT CFS2GSQ3FT 40W UNV PR Voltage Ballast 120 = 120V See page 4.86 277 = 277V UNV= 120-277V 1650 30˚ A Options See page 4.86 and page 4.130 For complete specification information visit www.lightolier.com Specification – Linear recessed and surface lighting Coffaire Dust/Insect Shield D 1x4 Dust Shield Dust Shield Liner For Coffaire series 1116" (23mm) Perforated Basket Features Plastic Stand off and debris from appearing on • Masks unsightly insects the perforated basket. • For use with Coffaire Series. • .040 Translucent white acrylic secondary liner6 ⅜" (161mm) 45 1116" (1167mm) Ordering information 1x4 Dust Shield Dust Shield Liner 2x2 & 2x4 Dust Shield Dust Shield Liner To specifiy dust/insect shield change PF in the catalog no. to PD 1116" (23mm) Example Standard With dust/insect sheild CFS2G PF 2FTUNVIB CFS2G PF 232UNVHI CFS2G PD 2FTUNVIB CFS2G PD 232UNVHI Perforated Basket 1116" (23mm) Perforated Basket Plastic Stand off Compatible with Coffaire Series Prefix CFS, CFH, CFA 1X4, 2X2 and 2X4 Sizes Plastic Stand off 6 ⅜" (161mm) Photometry: U se standard photometric tests and multiply light loss factor by 0.98 8 ⅛" (206mm) 45 1116" (1167mm) 45 1516" (1167mm) 21 1516" (557mm) 2x2 & 2x4 Dust Shield Dust Shield Liner Coffaire Dust Guard G For static Coffaire series Perforated Basket 1116" (23mm) Plastic Stand off Clear Lens 8 ⅛" (206mm) Features 45 1516" (1167mm) 21 1516" (557mm) Ordering information • Minimizes penetration of dust, insects and other debris into the lamp compartment. • Encloses lamp compartment. • Impact resistant clear acrylic lens. To specifiy dust/insect shield change PF in the Catalog no. to PG • Hinges at end caps. • Does not interfere with basket removal and relamping Example Standard With dust/insect sheild CFS2G PF 2FTUNVIB CFS2G PF 232UNVHI CFS2G PG 2FTUNVIB CFS2G PG 232UNVHI Compatible with Coffaire Series Prefix CFS, 2X2 and 2X4 Sizes Photometry: U se standard photometric tests and multiply light loss factor by 0.98 Comprehensive lighting catalog 7th Edition 4.87 Linear recessed and surface lighting – Specification DL Daylighting System Direct/indirect recessed luminaires Even when you have selected the most energy efficient luminaire/ballast/lamp combination for your space, additional energy savings can be made by utilizing natural daylight through use of controls. In the past, many have felt “Daylighting” was too complicated because of the wiring required for the interface of the fixtures to the control sensors, the adjustability of the sensors and the inflexibility if you relocated furniture or it did not quite work to your satisfaction. ULM-EZR Module can be relocated at any time with out use of tools. 4.88 Philips Lightolier ULM-EZR Module blends in with the ceiling system. With a low profile and visible flat dimension of 3" X 3.2" the ULM-EZR causes a minimal interruption to the ceiling plane. For complete specification information visit www.lightolier.com Specification – Linear recessed and surface lighting DL Daylighting System Direct/indirect recessed luminaires Now, Philips Lightolier makes daylighting as easy as 1-2-3. Step 1 Install Philips Lightolier recessed luminaires* which include a 0-10 volt dimming ballast and the #EZR option per your Lighting Layout and connect to AC power as you normally would any recessed luminaire. Step 2 Install a ULM-EZR module in the ceiling, positioning it 6 to 10 feet from windows and over a work surface (it must be within 10 ft of a luminaire). ULM-EZR modules can be moved or added at any time merely by plugging or unplugging the CAT5 cables. Both ULM-EZR modules and fixtures have RJ45 dual receptacles for the CAT5 cable with RJ45 plugs. ULM-EZR module sensor placement guidelines Before adjusting sensor settings, check to make sure they have been installed in accordance with the following guidelines: Step 3 Using the low voltage plug-in 12' long CAT5 cables provided with the luminaires*, connect the luminaire and ULM-EZR module. Sensor SHOULD be located. • Between 6-10’ away from window. • Over work surfaces. An additional CAT5 cable will be provided with each luminaire* to plug in additional luminaires* as in a daisy chain. Up to 20 luminaires* can be connected to a single ULM-EZR module. Sensor should NOT be located. • Over very dark surfaces (e.g. dark carpet or furniture). • Over highly reflective surfaces (e.g. polished floor or table). • Outside the daylit zone (typically beyond 15’ from window) When there is no daylight, place a lightmeter on the work surface and take a footcandle reading. Adjust to desired footcandle level by rotating the sensor in the face of the ULM-EZR Module. To get MORE light on desk from the luminaire, close aperture by rotating it counter-clockwise. The lamps will get brighter. To get LESS light on desk from the luminaire, open aperture by rotating it clockwise. The lamps will dim down. The sensors are factory pre-calibrated to 45fc on the horizontal, assuming standard reflectances (80/50/20), ceiling heights (8-10’) and work surfaces (2.5’). To return to the default setting, rotate the aperture until it ‘clicks’ back into place at the mid-point. Ordering information The DL System is the combination of the ULM-EZR Module (UF2F-EZR) and a Philips Lightolier recessed fluorescent fixture* with a 0-10 volt dimming ballast and the #EZR option. This option includes integrated RJ45 receptacles and a 12' long CAT5 cable. The module and luminaire need to be ordered separately. ULM-EZR Module: UL2F-EZR DL System fixture: Specify a Philips Lightolier recessed fluorescent fixture* with a 0-10 volt, 2 wire, dimming ballast and then add suffix #EZR. (e.g. CFS2GPF232UNVM7-#EZR) M7 Denotes Advance Mark VII dimming ballast for this lamping configuration. Other lamping configurations and dimming ballast manufacturers available. *Consult your Philips Lightolier representative for list of DL System compatible 1' x 4', 2' x 2' and 2' x 4' recessed fluorescent fixtures (Alter exempt). Comprehensive lighting catalog 7th Edition 4.89 Linear recessed and surface lighting Recessed & wall washing Recessed fluorescent luminaires represent just slightly less than 50% of all commercial and industrial fluorescents sold in the United States. They are usually the “A” fixture on a project. Their use has become popular over the years because the use of low ceiling heights dictates putting the fixture behind the ceiling instead of on it, and mechanical ceiling lay-in systems made the fixture less costly to install than surface or pendant luminaires. Our recessed line consists of many different body sizes and shielding media, such as large or small cell aluminum parabolic louvers, plastic parabolic louvers, and a variety of lenses, all to meet a designer’s application needs. Our vast product offering allows today’s designer to carefully select luminaires that will enhance any space and perform to exceptional standards. 4.90 Philips Lightolier For complete specification information visit www.lightolier.com Linear recessed and surface lighting Contents Lytecel 6 > 4.94 Prismalyte Plus > 4.122 CTS3 > 4.100 Specplus > 4.124 PTS family > 4.102 GO2 family > 4.106 FRX > 4.128 Vision Smart > 4.110 Options & accessories > 4.130 Stacklyte > 4.117 Deepcel Plus > 4.118 XP & XP /XA > 4.126 Quick-connect interties > 4.131 Wall washer & accent > 4.132 Comprehensive lighting catalog 7th Edition 4.91 Linear recessed and surface lighting Lighting for VDT areas ANSI/IES RP-1, 2004 requirements for lighting VDT areas The near-universal use of computers in office areas today is a major change in the workplace. Whereas office lighting was formerly designed to suit visual conditions for paper tasks in the horizontal plane, it must now take into consideration visual tasks comprised of a reflective visual display terminal (VDT) in the vertical plane and paper tasks in the horizontal or vertical plane. This means that a new set of parameters must be considered both to limit distracting reflections in the visual display terminal (VDT) and because of the potential for eye adaption problems; otherwise, a loss of visual performance will occur, with attendant problems of eyestrain, fatigue and loss of productivity. A number of authorities have concerned themselves with this issue, most notably the Illuminating Engineering Society, who in 1989 issued a recommended practice for lighting office areas containing visual display terminals, RP-24. This was replaced in 1993 and then in 2004 by the American National Standard for Office Lighting ANSI/IES RP-1 2004, which is accepted as the quality standard for the lighting of today’s office. To reduce contrast between the VDT screen and the surrounding area and tasks Illuminance: Average maintained illuminance levels should not exceed 50 footcandles on the horizontal plane. If a higher level is required because of older eyes or very demanding tasks, it should be provided by supplemental task lighting. In office work that requires constant viewing of the visual display (e.g.: telephone reservations or scientific and engineering dialogues with the computer) where paper based visual tasks are not important, illuminance should be kept as low as possible while still achieving good visual performance. Luminance ratios: Not more than 3:1 between the task and adjacent surfaces; not more than 10:1 between the task and remote surfaces. 1.3: 1 Brightness ratio 3: 1 Maximum (RP-1-04) 2.1: 1 Brightness ratio 3: 1 Maximum (RP-1-04) 3.4: 1 Brightness ratio 3: 1 Maximum (RP-1-04) 24 Horizontal footcandles 49 Horizontal footcandles 70 Horizontal footcandles Philips Lightolier VP1 Lamp Philips Lightolier VP2 Lamp Typical 3 Lamp. Does not meet IES RP-1 2004 requirements. To reduce direct glare from the lighting fixtures at normal viewing angles: Visual Comfort Probability (VCP): 80, minimum. To minimize reflections of the lighting fixtures in the VDT screen. A ngle from Vertical 55° 65° 75° 85° VDT Intensive VDT Normal 300 cd 220 cd 135 cd 45 cd — 300 cd 185 cd 60 cd VDT screen in a space with fixtures that do not meet RP-1, 2004. VDT screen in a space with fixtures that meet RP-1, 2004. Note: This table shows candlepower values, not luminance values as in previous recommendations. 4.92 Philips Lightolier For complete specification information visit www.lightolier.com Linear recessed and surface lighting Philips Lightolier suggested LEED luminaires Comparisons in office space Direct/indirect recessed Philips Lightolier catalog no. Family Lamp Lamp lumens Watts BF Luminaire spacing fc* w/sq ft 90.1 1999 90.1 2004 % LEED % LEED H9S2GPR228120WA HP90 T5 28W 2600 54.6 0.93 8X10 55.2 0.683 47.47% 31.70% H9S2GPR232(28)UNV HP90 T5 28W 2725 51.1 0.88 8X10 50.6 0.639 50.85% 36.10% 30.70% PPH2G12FW228120WA Paraplus T5 28W 2600 55.4 0.93 8X10 48.9 0.693 46.69% H9S2GPR228120WA HP90 T5 28W 2600 54.6 0.93 8X10 48.0 0.630 51.54% 37.00% H9S2GPR232(28)UNV HP90 T5 28W 2725 51.1 0.88 8X10 41.5 0.590 54.62% 41.00% 35.40% PPH2G12FW228120WA Paraplus T5 28W 2600 56 0.93 8X10 44.0 0.646 50.31% H9S2GPR228120WA HP90 T5 28W 2600 54.6 0.93 8 44.2 0.910 30.00% 9.00% H9S2GPR232(28)UNV HP90 T5 28W 2725 51.1 0.88 8 37.9 0.852 34.46% 14.80% PPH2G12FW228120WA Paraplus T5 28W 2600 56 0.98 8 42.3 0.933 28.23% 6.70% 90.1 1999 90.1 2004 % LEED % LEED 35.00% Recessed direct Philips Lightolier catalog no. Family Lamp Lamp lumens Watts BF Luminaire spacing fc* w/sq ft DPA2G12LS232120WO Deepcel T8 30W 2900 52 0.88 8X10 50.9 0.650 50.00% DPA2G12LS232120DG Deepcel T8 32W 2950 77 1.20 8X10 70.6 0.963 25.92% 3.70% SPS2GFSVA232120WO Specline T8 30W 2900 52 0.88 8X10 52.3 0.650 50.00% 35.00% SPS2GFSVA232120DG Specline T8 32W 2950 77 1.20 8X10 72.6 0.963 25.92% 3.70% 40.00% DPA2G12LS232120WO Deepcel T8 30W 2900 52 0.88 8X10 46.1 0.600 53.85% DPA2G12LS232120DG Deepcel T8 32W 2950 77 1.20 8X10 62.9 0.888 31.69% 11.20% SPS2GFSVA232120WO Specline T8 30W 2900 52 0.88 8X10 48.6 0.600 53.85% 40.00% SPS2GFSVA232120DG Specline T8 32W 2950 77 1.20 8X10 64.7 0.888 31.69% 11.20% DPA2G12LS232120WO Deepcel T8 30W 2900 52 0.88 8 46.8 0.867 33.31% 13.30% SPS2GFSVA232120WO Specline T8 30W 2900 52 0.88 8 46.9 0.867 33.31% 13.30% 60' x 56' Room 30' x 26' Room 12' x 10' Room Comprehensive lighting catalog 7th Edition 4.93 Linear recessed and surface lighting – Professional Lytecel 6 Lens LED 6" x 48" Direct recessed air return or static luminaires The Lytecel 6 LED recessed lens brings both flexibility and unity to lighting. Create continuous lines of light with the recessed Lytecel 6 Lens LED. Its crisp, clean lines and minimalist design is sure to bring style, freshness and subtle distinction to modern office and retail interiors. A unique non-visible return air opening allows this product to have air return capabilities if needed. It fits most standard 6" X 48" lay in systems and is designed specifically for the Armstrong TechZone® ceiling systems. Features • Non-visible return air openings. LIA64GPN28A40ULAG • Air return lens regressed 1-9/16", static regressed 1-3/16". 6" (152mm) 5" (126mm) • Air return models meet UL 1598, Paragraph 9.2.2.5 requirements. 6" (152mm) 5" (126mm) LED Driver • Extruded aluminum fixture trim flat white polyester powder coated. • Extruded .080 white opalescent acrylic lens. • Only 6" deep body. 6" (152mm) 6" (152mm) • Can provide 34 initial footcandles at 0.53 watts per square foot. • Delivers 2864 lumens with just 44.9 input watts. 1 916" (40mm) • Field replaceable LED array and drivers accessible from below. 1 ⅛" (30mm) 5 ¾" (146mm) • Integrated thermal management system conducts heat away from LEDs and transfers it to the surrounding environment. 5 ¾" (146mm) Air Return Static Lens 2 ⅞" K.O. (22mm) • High efficiency LEDs have 50,000 hour rated life at L70. ⅞" K.O. (22mm) • Predicted L70 lifetime is based on LED manufacturer’s supplied LM-80 data and in-situ laboratory testing. • 20 gauge steel housing. • UL-Listed twin knockout access plate. • 2 hold-down clips standard. 4 ¼" (108mm) 48" (1,219mm) • Meets NYC Code requirements. • Compatible with Armstrong TechZone ceiling systems. • Five-year warranty on luminaire, LED boards and driver. Options & accessories Ordering information Delivered lumens Type Drywall kit: For individual mounts only: FK906X4. Access plate: Top wiring access plate is shipped with fixture as standard. When access plates are required in advance for wiring convenience, specify separately. Order catalog no.: ACP5 CSP. EM Pack or dimming ballast: Consult factory. Fusing: Suffix: A (Internal fast-blow fusing). Suffix: C (Internal slow-blow fusing). Chicago Plenum: Suffix: C. For products that meet Chicago Plenum requirements. Air return and Static 2011 2500 2864 3174 Input watts 30.0 38.4 44.9 50.8 Lumens 8'x10½" initial 8'x10½' watts Catalog no. per watt footcandles* per sq. foot 67.0 65.1 63.8 62.5 24 30 34 38 0.36 0.46 0.53 0.60 LIA64GPN20A40ULAG LIA64GPN25A40ULAG LIA64GPN28A40ULAG LIA64GPN31A40ULAG For Static Handling housing models substitute LIS64 for LIA64. * 42 Recessed LED Luminaires in a 60' x 56' x 9' room with a reflectance of 80/50/20, placed 8' x 10' on center. Footcandle readings are taken 2 ½' from floor level. Example LIA64G Lytecel 6 Lens shielding LED PN = .08 White Direct Acrylic Recessed 40 U LAG 2 Lumen Color temp Voltage Driver Options 20A = 20k lm 40 = 4000K UNV = LAG = See page 4.94 25A = 25k lm 120-277V LED Driver 28A = 28k lm 31A = 31k lm 1 1,2 1. Approximate delivered values (Consult IES file). 2. Consult representative for other color temperature options and driver dimming options. 4.94 Philips Lightolier For complete specification information visit www.lightolier.com Professional – Linear recessed and surface lighting Lytecel 6 Lens 6" x 48" Direct recessed air return or static luminaires Lytecel 6 Lens is an extension of our popular Lytecel 6 parabolic product line. Lytecel 6 Lens offers a low in brightness extruded white opalescent acrylic lens, allowing the right amount of light to be delivered to walls and work surfaces in an office environment. A unique non-visible return air opening allows this product to have air return capabilities if needed. It fits most standard 6" X 48" lay in systems and is designed specifically for the Armstrong TechZone® ceiling systems. Features LIA6GPNXR254UNVPG • Non-visible return air openings. 6" (152mm) • Lens regressed 1 9/16". 6" (152mm) 4 1516" (126mm) • Fixture trim flat white polyester powder coated. 4 1516" (126mm) • Extruded.080 white opalesent acrylic lens. • Only 6" deep body. • 64.3% efficient 1 lamp 54 Watt T5HO with lens. • 1.2 spacing mounting ratio. 6" (152mm) 6" (152mm) 1 916" (40mm) • 20 gauge steel housing. • Black housing exterior for cooler ballast operating temperature. • UL-Listed twin knockout access plate. 1 ⅛" (30mm) 5 ¾" (146mm) • Can be mounted in continuous rows. • 2 hold-down clips standard. 5 ¾" (146mm) • Compatible with Armstrong TechZone ® ceiling systems. Static Air Return • Meets NYC Code requirements. ⅞" K.O. (22mm) 2 ⅞" K.O. (22mm) • Optional DALI ballast accepts digital dimming commands from computers, scene controllers and automatic control devices. Options & accessories 4 ¼" (108mm) Ballast type <10THD <20THD 48" (1,219mm) Ordering information Type Lamp qty –type page 4.130 Lamp watts Standard grid ceiling = G Slot grid ceiling = T Air return 2-T5HO 1-T5HO 2-T5 1-T5 2-T8 1-T8 54W 54W 28W 28W 32W 32W LIA6GPNXR254 LIA6GPNXR154 LIA6GPNXR228 LIA6GPNXR128 LIA6GPNXR232 LIA6GPNXR132 LIA6TPNXR254 LIA6TPNXR154 LIA6TPNXR228 LIA6TPNXR128 LIA6TPNXR232 LIA6TPNXR132 Static 2-T5HO 1-T5HO 2-T5 1-T5 2-T8 1-T8 54W 54W 28W 28W 32W 32W LIS6GPNXR254 LIS6GPNXR154 LIS6GPNXR228 LIS6GPNXR128 LIS6GPNXR232 LIS6GPNXR132 LIS6TPNXR254 LIS6TPNXR154 LIS6TPNXR228 LIS6TPNXR128 LIS6TPNXR232 LIS6TPNXR132 Electronic T8 HI* Elec. PS T8 32W (1 or 2 Lamp) P2 – SO* Elec. T5 P.S. 28W or 54W PG – * Instant start Drywall kit: For individual mounts only: FK906X4. Access plate: Top wiring access plate is shipped with fixture as standard. When access plates are required in advance for wiring convenience, specify separately. Order catalog no.: ACP5 CSP. Electrical/wiring options: Consult factory. EM Pack or dimming ballast: Consult factory. Fusing: Suffix: A (Internal fast-blow fusing). Suffix: C (Internal slow-blow fusing). Chicago Plenum: Suffix: C. For products that meet Chicago Plenum requirements. * For any additional ceiling systems not shown please consult factory. Example LIA6GPNXR154 Lytecel 6 6" x 48" Recessed Lens UNV PG Voltage Ballast 120 = 120V See page 4.95 277 = 277V UNV= 120-277V (Elect T5 or T8) A Options See page 4.95 and page 4.130 Comprehensive lighting catalog 7th Edition 4.95 Linear recessed and surface lighting – Professional Lytecel 6 individual T5 6" x 48" Recessed parabolic luminaires Features a low brightness 20 cell parabolic louver that has an opening that is only 4¼" wide. The precise contours provide photometrics that meet the IES requirements for lighting VDT areas. It fits most standard 6" X 48" lay-in ceiling systems plus Armstrong TechZone® ceiling systems. Features • Semi-specular or specular, low iridescence, pre-anodized aluminum louver. LIS6G20PW154UNVPG • Vertical grain on cross blades eliminates reflected lamp image. 5 ½" (139mm) • Spring loaded latches (self centering). • Louver has protective dust guard. 5 ½" (139mm) • Only 5-1/2" deep body. • Black housing exterior for cooler ballast operating temperature. 4 ¼" (108mm) • Can be mounted in continuous rows. • 2 hold-down clips standard. • Compatible with Armstrong TechZone ® ceiling systems. • Optional DALI ballast accepts digital dimming commands from computers, scene controllers and automatic control devices. 5 ½" (139mm) 5 ½" (139mm) page 4.130 4 ¼" (108mm) Louver: LI is available in either specular (P) or semi-specular (L) louvers. (e.g. LIS6G20PW228 or LISG20LW228) 6" 4 ¼"(152mm) (108mm) 6" Slot Grid ceiling (152mm) Ballast type <10THD <20THD Electronic PS T5 (1 or 2 Lamp) (28W or 54W) Electronic ballast Input watts (120V) 59.0W Ballast factor 1.0 60˚ 500 1000 1500 30˚ Standard T-Grid ceiling LIS6G20PW228UNVPG • Meets NYC Code requirements. Options & accessories Efficiency 58.2% Spacing ratio 1.6 6" 4 ¼"(152mm) (108mm) 6" Standard T-Grid ceiling (152mm) • UL-Listed twin knockout access plate. Candlepower Curve 1 Lamp T5 specular louver reference data Candlepower Curve 2 Lamp T5 specular louver reference data Efficiency 55.3% Spacing ratio 1.5 Electronic ballast Input watts (120V) 66.0W Ballast factor 1.0 60˚ 550 1100 1650 30˚ Slot Grid ceiling PG – Drywall kit: For individual mounts only: FK906X4. Access plate: Top wiring access plate is shipped with fixture as standard. When access plates are required in advance for wiring convenience, specify separately. Order Catalog no.: ACP5 CSP. Electrical/wiring options: Consult factory. EM Pack or dimming ballast: Consult factory. Example LIS6G20PW154 Lytecel 6 6" x 48" Recessed parabolic UNV Voltage 120 = 120V 277 = 277V UNV= 120-277V (Elect T5) PG Ballast See page 4.96 Options See page 4.96 and page 4.130 Fusing: Suffix: A (Internal fast-blow fusing). Suffix: C (Internal slow-blow fusing). Chicago Plenum: Suffix: C. For products that meet Chicago Plenum requirements. Ordering information Type Standard grid ceiling = G Slot grid ceiling = T Tegular 9/16" ceiling = D Tegular 15/16" ceiling = A Static 1-T5 2-T5 1-T5 2-T5 28W 28W 54W 54W LIS6G20PW128UNVPG LIS6G20PW228UNVPG LIS6G20PW154UNVPG LIS6G20PW254UNVPG LIS6T20PW128UNVPG LIS6T20PW228UNVPG LIS6T20PW154UNVPG LIS6T20PW254UNVPG LIS6D20PW128UNVPG LIS6D20PW228UNVPG LIS6D20PW154UNVPG LIS6D20PW254UNVPG LIS6A20PW128UNVPG LIS6A20PW228UNVPG LIS6A20PW154UNVPG LIS6A20PW254UNVPG Air handling 1-T5 2-T5 1-T5 2-T5 28W 28W 54W 54W LIA6G20PW128UNVPG LIA6G20PW228UNVPG LIA6G20PW154UNVPG LIA6G20PW254UNVPG LIA6T20PW128UNVPG LIA6T20PW228UNVPG LIA6T20PW154UNVPG LIA6T20PW254UNVPG LIA6D20PW128UNVPG LIA6D20PW228UNVPG LIA6D20PW154UNVPG LIA6D20PW254UNVPG LIA6A20PW128UNVPG LIA6A20PW228UNVPG LIA6A20PW154UNVPG LIA6A20PW254UNVPG 4.96 Lamp qty –type Philips Lightolier Lamp watts For complete specification information visit www.lightolier.com Professional – Linear recessed and surface lighting Lytecel 6 individual T8 6" x 48" Recessed parabolic luminaires Features a low brightness 20 cell parabolic louver that has an opening that is only 4¼" wide. The precise contours provide photometrics that meet the IES requirements for lighting VDT areas. It fits most standard 6" X 48" lay-in ceiling systems plus Armstrong TechZone® ceiling systems. Features LIS6G20PW132UNVHI Candlepower Curve 1 Lamp T8 specular louver reference data 5 ½" (139mm) Efficiency 57.6% Spacing ratio 1.7 5 ½" (139mm) Electronic ballast Input watts (120V) 39.0W Ballast factor 1.1 4 ¼" (108mm) 6" 4 ¼"(152mm) (108mm) 6" Standard T-Grid ceiling (152mm) • Vertical grain on cross blades eliminates reflected lamp image. 60˚ 250 • Spring loaded latches (self centering). • Louver has protective dust guard. • Only 5-1/2" deep body. 500 • Black housing exterior for cooler ballast operating temperature. 750 30˚ • UL-Listed twin knockout access plate. • Can be mounted in continuous rows. • 2 hold-down clips standard. • Compatible with Armstrong TechZone ® ceiling systems. Standard T-Grid ceiling LIS6G20PW232UNVHI 5 ½" (139mm) 5 ½" (139mm) 4 ¼" (108mm) • Meets NYC Code requirements. Candlepower Curve 2 Lamp T8 specular louver reference data Efficiency 51.6% Spacing ratio 1.5 Electronic ballast Input watts (120V) 78.0W Ballast factor 1.1 6" 4 ¼"(152mm) (108mm) 6" Slot Grid ceiling (152mm) 60˚ 500 1000 1500 LIS6G20PW132 UNV Lytecel 6 6" x 48" Recessed parabolic Voltage 120 = 120V 277 = 277V UNV= 120-277V (Elect T8) • Optional DALI ballast accepts digital dimming commands from computers, scene controllers and automatic control devices. Options & accessories page 4.130 Louver: LI is available in either specular (P) or semi-specular (L) louvers. (e.g. LIS6G20PW228 or LISG20LW228) 30˚ Slot Grid ceiling Example • Semi-specular or specular, low iridescence, pre-anodized aluminum louver. HI Ballast type <10THD <20THD Elec. IS T8 32W (1 or 2 Lamp) HI SO Elec. PS T8 32W (1 or 2 Lamp) P2 – Drywall kit: For individual mounts only: FK906X4. Ballast See page 4.97 Options See page 4.97 and page 4.130 Access plate: Top wiring access plate is shipped with fixture as standard. When access plates are required in advance for wiring convenience, specify separately. Order Catalog no.: ACP5 CSP. Electrical/wiring options: Consult factory. EM Pack or dimming ballast: Consult factory. Fusing: Suffix: A (Internal fast-blow fusing). Suffix: C (Internal slow-blow fusing). Chicago Plenum: Suffix: C. For products that meet Chicago Plenum requirements. Ordering information Type Lamp qty –type Static 1-T8 2-T8 Air handling 1-T8 2-T8 Lamp watts Standard grid ceiling = G Slot grid ceiling = T Tegular 9/16" ceiling = D Tegular 15/16" ceiling = A 32W LIS6G20PW132UNVHI LIS6G20PW232UNVHI LIS6T20PW132UNVHI LIS6T20PW232UNVHI LIS6D20PW132UNVHI LIS6D20PW232UNVHI LIS6A20PW132UNVHI LIS6A20PW232UNVHI 32W LIA6G20PW132UNVHI LIA6G20PW232UNVHI LIA6T20PW132UNVHI LIA6T20PW232UNVHI LIA6D20PW132UNVHI LIA6D20PW232UNVHI LIA6A20PW132UNVHI LIA6A20PW232UNVHI Comprehensive lighting catalog 7th Edition 4.97 Linear recessed and surface lighting – Professional Lytecel 6 continuous T5 6" x 48" Recessed parabolic luminaires Features a low brightness 20 cell parabolic louver that has an opening that is only 4 ¼" wide and a length of 48". When mounted in continuous rows it creates an uninterrupted continuous louver appearance. It will fit most 6" wide lay-in or slot grid ceiling systems and has unique aligning and clamping hardware that creates the proper fit of the fixture into the ceiling system. Features • 48" long louver gives an uninterrupted louver appearance when row mounted. Ideal for continuous row applications. LCS6G20PW154UNVPG • Semi-specular or specular, low iridescence, preanodized aluminum louver. • Vertical grain on cross blades eliminates reflected lamp image. Electronic ballast 5 ½" (139mm) • Spring loaded latches (self centering). Input watts (120V) 59.0W Ballast factor 1.0 4 ¼" (108mm) • Louver has protective dust guard. 6" 4 ¼"(152mm) (108mm) 6" Standard T-Grid ceiling (152mm) • Only 5-1/2" deep body. • Black housing exterior for cooler ballast operating temperature. • UL-Listed twin knockout access plate. • Meets NYC Code requirements. 5 ½" (139mm) • Optional DALI ballast accepts digital dimming commands from computers, scene controllers and automatic control devices. 5 ½" (139mm) 4 ¼" (108mm) page 4.130 30˚ PI Elec. PS T5 28W or 54W (1 or 2 Lamp) PG – SO Elec IS T8 32W (1 or 2 Lamp) HI – Access plate: Top wiring access plate is shipped with fixture as standard. When access plates are required in advance for wiring convenience, specify separately. Order Catalog no.: ACP5 CSP. Electrical/wiring options: Consult factory. Chicago Plenum: Suffix: C. For products that meet Chicago Plenum requirements. Electronic ballast 60˚ 550 1100 1650 30˚ Ordering information Type Standard grid ceiling = G Slot grid ceiling = T Static 1-T5 2-T5 1-T5 2-T5 28W 28W 54W 54W LCS6G20PW128UNVPG LCS6G20PW228UNVPG LCS6G20PW154UNVPG LCS6G20PW254UNVPG LCS6T20PW128UNVPG LCS6T20PW228UNVPG LCS6T20PW154UNVPG LCS6T20PW254UNVPG Air handling 1-T5 2-T5 1-T5 2-T5 28W 28W 54W 54W LCA6G20PW128UNVPG LCA6G20PW228UNVPG LCA6G20PW154UNVPG LCA6G20PW254UNVPG LCA6T20PW128UNVPG LCA6T20PW228UNVPG LCA6T20PW154UNVPG LCA6T20PW254UNVPG EM Pack or dimming ballast: Consult factory. Fusing: Suffix: A (Internal fast-blow fusing). Suffix: C (Internal slow-blow fusing). Efficiency 55.3% Spacing ratio 1.5 Slot Grid ceiling Ballast type <10THD <20THD Elec. IS T5 28W (1 or 2 Lamp) Candlepower Curve 2 Lamp T5 specular louver reference data Input watts (120V) 66.0W Ballast factor 1.0 6" 4 ¼"(152mm) (108mm) 6" Slot Grid ceiling (152mm) Louver: LC is available in either specular (P) or semi-specular (L) louvers. (e.g. LCS6G20PW228 or LCS6G20LW228) Example Lamp qty –type Lamp watts LCS6G20PW154 Lytecel 6 6" x 48" Recessed parabolic End trim required for beginning and end of row. Order catalog no.: LC6 End trim Philips Lightolier 1000 1500 LCS6G20PW228UNVPG • 2 hold-down clips standard. 4.98 60˚ 500 Standard T-Grid ceiling • Can be mounted in continuous rows. Options & accessories Efficiency 58.2% Spacing ratio 1.6 5 ½" (139mm) Candlepower Curve 1 Lamp T5 specular louver reference data UNV Voltage 120 = 120V 277 = 277V UNV= 120-277V (Elect T5 or T8) PG Ballast See page 4.98 Options See page 4.98 and page 4.130 Continuous row coupler locks fixtures together for a continuous line of light without cell configuration interruption,supplied with fixture. (For end of row order LC85 CLAMP) For complete specification information visit www.lightolier.com Professional – Linear recessed and surface lighting Lytecel 6 continuous T8 6" x 48" Recessed parabolic luminaires Features a low brightness 20 cell parabolic louver that has an opening that is only 4 ¼" wide and a length of 48". When mounted in continuous rows it creates an uninterrupted continuous louver appearance. It will fit most 6" wide lay-in or slot grid ceiling systems and has unique aligning and clamping hardware that creates the proper fit of the fixture into the ceiling system. LCS6G20PW132UNVHI Features Efficiency 57.6% Spacing ratio 1.7 5 ½" (139mm) Electronic ballast 5 ½" (139mm) Input watts (120V) 39.0W Ballast factor 1.1 4 ¼" (108mm) Candlepower Curve 1 Lamp T8 specular louver reference data 60˚ 250 • Vertical grain on cross blades eliminates reflected lamp image. 500 • Spring loaded latches (self centering). 750 30˚ LCS6G20PW232UNVHI 5 ½" (139mm) 5 ½" (139mm) 4 ¼" (108mm) Candlepower Curve 2 Lamp T8 specular louver reference data Efficiency 51.6% Spacing ratio 1.5 Electronic ballast 60˚ 500 1500 30˚ 1-T8 2-T8 • Meets NYC Code requirements. • Optional DALI ballast accepts digital dimming commands from computers, scene controllers and automatic control devices. page 4.130 Louver: LC is available in either specular (P) or semi-specular (L) louvers. (e.g. LCS6G20PW232 or LCS6G20LW232) Ballast type <10THD <20THD Ordering information Air handling • 2 hold-down clips standard. Options & accessories 1000 Slot Grid ceiling Static • Black housing exterior for cooler ballast operating temperature. • Can be mounted in continuous rows. Input watts (120V) 78.0W Ballast factor 1.1 6" 4 ¼"(152mm) (108mm) 6" Slot Grid ceiling (152mm) 1-T8 2-T8 • Only 5-1/2" deep body. • UL-Listed twin knockout access plate. Standard T-Grid ceiling Lamp qty –type • Semi-specular or specular, low iridescence, preanodized aluminum louver. • Louver has protective dust guard. 6" 4 ¼"(152mm) (108mm) 6" Standard T-Grid ceiling (152mm) Type • 48" long louver gives an uninterrupted louver appearance when row mounted. Ideal for continuous row applications. Lamp watts Standard grid ceiling = G Slot grid ceiling = T 32W LCS6G20PW132UNVHI LCS6G20PW232UNVHI LCS6T20PW132UNVHI LCS6T20PW232UNVHI 32W LCA6G20PW132UNVHI LCA6G20PW232UNVHI LCA6T20PW132UNVHI LCA6T20PW232UNVHI Elec. IS T8 32W (1 or 2 Lamp) HI SO Elec. PS T8 32W (1 or 2 Lamp) P2 – Access plate: Top wiring access plate is shipped with fixture as standard. When access plates are required in advance for wiring convenience, specify separately. Order catalog no.: ACP5 CSP. Electrical/wiring options: Consult factory. Example LCS6G20PW132 Lytecel 6 6" x 48" Recessed parabolic End trim required for beginning and end of row. Order catalog no.: LC6 ENd trim UNV Voltage 120 = 120V 277 = 277V UNV= 120-277V (Elect T8) EM Pack or dimming ballast: Consult factory. HI Ballast See page 4.99 Options See page 4.99 and page 4.130 Fusing: Suffix: A (Internal fast-blow fusing). Suffix: C (Internal slow-blow fusing). Chicago Plenum: Suffix: C. For products that meet Chicago Plenum requirements. Continuous row coupler locks fixtures together for a continuous line of light without cell configuration interruption,supplied with fixture. (For end of row order LC85 CLAMP) Comprehensive lighting catalog 7th Edition 4.99 Linear recessed and surface lighting – Professional CTS3 2', 4' & 8' 1 lamp recessed luminaires Flush Lens 3 ¾" (95mm) CTS3-1 3 ¾" (95mm) 5 ¼" (133mm) 3" (76mm) Features Housing: 20 gauge pre-painted steel. Bulkhead: 18 gauge galvanized steel Reflector: Semi-specular aluminum. Trim: Flange has an aluminum extruded width of 3/4". Flangeless and grid mount has no trim visible. Grid mount fixture drops into grid system by others. Lamping: T5 or T5 HO fluorescent. Lens: Extruded frosted acrylic. 3 ¾" (95mm) 5 ¼" (133mm) 3" (76mm) Flangeless 5 ⅛" (130mm) 3" (76mm) Candlepower Curve CTS3-13 60˚ 300 600 Grid Mount 900 Distribution 30˚ Zone Lumens %Lamp %Luminaire 0-90 1854 37.8 100.0 90-180 0 0.0 0 0-180 1854 37.8 100.0 Regressed Lens 3 ¾" (95mm) Louver: Extruded Semi specular parabolic, 2" nominal blade spacing. Electronic ballast: Extruded Programmed start, 3 conductors, 12 gauge wire. Color-coded quick connectors allow easy connection for modular fixture. CTS3-3 3 ¾" (95mm) 5 ¼" (133mm) Emergency battery pack: 450 Lumens @ 90 minimum. Labels included: UL, cUL, and IBEW Flange CTS3-7 3" (76mm) Flange CTS3-9 3 ¾" (95mm) 5 ¼" (133mm) 3" (76mm) Flangeless 5 ⅛" (130mm) 3" (76mm) Candlepower Curve CTS3-15 60˚ 300 600 Grid Mount 900 Distribution 30˚ Zone Lumens %Lamp %Luminaire Ordering instructions Continuous rows: 1. Determine run length. 2. Order starter fixture. . 3. Order one telescoping fixture*. 4. Order remainder of joiner fixtures. Individual Fixtures: 0-90 1815 37.1 100.0 90-180 0 0.0 0 0-180 1815 37.1 100.0 Parabolic Louver 1. Order number of INDIVIDUAL UNITS required 3 ¾" (95mm) *For best one lamp effect, use telescoping fixture at longest length possible. CTS3-5 3 ¾" (95mm) 5 ¼" (133mm) 3" (76mm) Flange CTS3-11 3 ¾" (95mm) 5 ¼" (133mm) 3" (76mm) Flangeless 5 ⅛" (130mm) 3" (76mm) Candlepower Curve CTS3-17 300 60˚ 600 Grid Mount 900 Distribution 30˚ Zone Lumens %Lamp %Luminaire 0-90 1880 38.4 100.0 90-180 0 0.0 0 0-180 1880 38.4 100.0 Ordering information CT3 A Family Mounting CT3 = CTS3 F = Flange L = Flush Lens A = 1 Lamp 1 L = Flangeless R = Recessed Lens G = Grid Mount P = Parabolic Louver 1 Shielding Configuration Output Length (nom.) Housing H = High Output 2 = 2 Foot S = Standard 4 = 4 Foot 8 = 8 Foot Lamp is mounted diagonally and extends into adjacent fixture by 2 1/2" in starter, joiner and telescoping fixtures Starter available as 4' and 8' only 3 Telescoping fixture ships 85 3/8", adjustable down to 49 3/8" 4 EM pack not available in 2' or telescoping fixtures Voltage U = Indiv. Unit 1 = 120V S = Starter 2 2 = 277V J = Joiner T = Telescoping 3 Options 4 = 4 through wires 5 = 5 through wires T = Tandem Switch E = Emergency Pack 4 2 4.100 Philips Lightolier For complete specification information visit www.lightolier.com Professional – Linear recessed and surface lighting CTS3 2', 4' & 8' 2 lamp recessed luminaires Flush Lens 3 ¾" (95mm) CTS3-2 3 ¾" (95mm) 5 ¼" (133mm) 3" (76mm) Flange CTS3-8 3 ¾" (95mm) 5 ¼" (133mm) 3" (76mm) 5 ⅛" (130mm) 3" (76mm) Flangeless Candlepower Curve CTS3-14 60˚ 300 600 Grid Mount 900 Distribution 30˚ Zone Lumens %Lamp %Luminaire 0-90 3429 35.0 100.0 90-180 0 0.0 0 0-180 3429 35.0 100.0 Features Housing: 20 gauge pre-painted steel. Bulkhead: 18 gauge galvanized steel Reflector: Semi-specular aluminum. Regressed Lens 3 ¾" (95mm) CTS3-4 3 ¾" (95mm) 5 ¼" (133mm) 3" (76mm) Flange CTS3-10 3 ¾" (95mm) 5 ¼" (133mm) 3" (76mm) 5 ⅛" (130mm) 3" (76mm) Flangeless Candlepower Curve CTS3-16 60˚ 500 Lamping: T5 or T5 HO fluorescent. Lens: Extruded frosted acrylic. Louver: Extruded Semi specular parabolic, 2" nominal blade spacing. 1000 Grid Mount 1500 Distribution Trim: Flange has an aluminum extruded width of 3/4". Flangeless and grid mount has no trim visible. Grid mount fixture drops into grid system by others. 30˚ Zone Lumens %Lamp %Luminaire Electronic ballast: Extruded programmed start, 3 conductors, 12 gauge wire. Color-coded quick connectors allow easy connection for modular fixture. Emergency battery pack: 450 Lumens @ 90 minimum. 0-90 3158 32.2 100.0 90-180 0 0.0 0 0-180 3158 32.2 100.0 Labels included: UL, cUL, and IBEW Ordering instructions Continuous rows: Parabolic Louver 3 ¾" (95mm) CTS3-6 3 ¾" (95mm) 5 ¼" (133mm) 3" (76mm) Flange CTS3-12 3 ¾" (95mm) 5 ¼" (133mm) 3" (76mm) 5 ⅛" (130mm) 3" (76mm) Flangeless Candlepower Curve CTS3-18 650 60˚ Individual fixtures: 1. Order number of INDIVIDUAL UNITS required *For best one lamp effect, use telescoping fixture at longest length possible. 1300 Grid Mount 1950 Distribution 1. Determine run length. 2. Order starter fixture. . 3. Order one telescoping fixture*. 4. Order remainder of joiner fixtures. 30˚ Zone Lumens %Lamp %Luminaire 0-90 3483 35.5 100.0 90-180 0 0.0 0 0-180 3483 35.5 100.0 Ordering information CT3 C Family Mounting CT3 = CTS3 F = Flange L = Flush Lens C = 2 Lamp 1 L = Flangeless R = Recessed Lens G = Grid Mount P = Parabolic Louver 1 Shielding Configuration Output Length (nom.) Housing H = High Output 2 = 2 Foot S = Standard 4 = 4 Foot 8 = 8 Foot Lamp is mounted diagonally and extends into adjacent fixture by 2 1/2" in starter, joiner and telescoping fixtures Starter available as 4' and 8' only 3 Telescoping fixture ships 85 3/8", adjustable down to 49 3/8" 4 EM pack not available in 2' or telescoping fixtures Voltage U = Indiv. Unit 1 = 120V S = Starter 2 2 = 277V J = Joiner T = Telescoping 3 Options 4 = 4 through wires 5 = 5 through wires T = Tandem Switch E = Emergency Pack 4 2 Comprehensive lighting catalog 7th Edition 4.101 Linear recessed and surface lighting – Professional PTS7 2', 3', 4', 5' & 7' Perimeter trough system PTS7-1 1 Light T8, parabolic louver, 8 1/4" aperture Report no: LRL 499-5D Efficiency: 46.7% Lamps: 1-FO32T8 7 116" (179mm) Distribution Features Housing: Die-formed steel. Integral flanges at each end strengthen the housing and permit housings to be bolted together in continuous runs and facilitate suspension of fixture. Concealed openings for heat extraction. Lamping: One or two T8 fluorescent lamps, as specified. Provided by others. Reflector: Die-formed semi-specular aluminum. Louver: Semi-specular anodized aluminum, 40 degrees lengthwise by 30 degrees minimum crosswise shielding. Supported along both edges by concealed frame of extruded aluminum. Socket Channels: Die-formed, prepainted steel held by support brackets and allows for up to 6" lamp overlap. Ceiling Trim: Extruded aluminum with integral aligner splines. Electrical: Specify 120 volt or 277 volt. 3 conductor, 12 gauge wire. Color-coded quick connectors allow ease of connection for joiner modules. For special circuiting, consult factory. Rapid start, HPF, class “P” thermally protected. Emergency battery pack: 450 Lumens @ 90 minimum. 4' fixture and longer only. Not available in telescoping fixtures. Mountings: Wall adjustment bracket - allows for inconsistencies in wall straightness. Die-formed steel used to mount system to the wall. Candlepower Curve Reference data 11 ¼" (286mm) Zone Lumens %Lamp %Luminaire 8 ¼" (210mm) 0-90 2644 45.6 100.0 90-180 0 0.0 0.0 0-180 2644 45.6 100.0 300 60˚ 600 900 30˚ Ordering information PTS7 Family 1 Style Lamps Length Ballast 1 = 1 Lamp 24 = 24" T = Telescoping * 36 = 36" Blank = Non-telescoping 48 = 48" * * PTS7-1 lamp telescoping available 60 = 60" in 48" with adjustment of 27" to 48". 84 = 84" PTS7 = PTS7 Options E81 = ELET8 120V X4 = 4 through wires E82 = ELE T8 277V X5 = 5 through wires X6 = 6 through wires T = Tandem switch End plate and corner block accessories 90° Inside PTS7C901 Standard 90 Inside 90° Outside PTS7C900 Standard 90 Outside 1 ½'' (38mm) 135° Inside PTS7C1351 Standard 135° Outside PTS7C1350 Standard 135 Inside 8 ½'' (213mm) 4 ¾" (12mm) 14'' (356mm) Finish: Ceiling trim painted baked enamel semi-gloss white. Options and Accessories 90 degree inside, 90 degree outside, 135 degree inside, and 135 outside corners available. End cap set PTS7EP Standard Labels UL, cUL and I.B.E.W. Each run must be closed up by one End cap set 4.102 Philips Lightolier For complete specification information visit www.lightolier.com Professional – Linear recessed and surface lighting PTS7 2', 3', 3 ½', 4 ½', 5' & 8' Perimeter trough system PTS7-2 2 Light T8, parabolic louver, 8 1/4" aperture 7 116" (179mm) Candlepower Curve Reference data 11 ¼" (286mm) Report no: Lamps: Lumens: Efficiency: LRL 499-5E 2-32WT8 2900 45.6% 500 Distribution Zone Lumens %Lamp %Luminaire 8 ¼" (210mm) 0-90 2644 45.6 100.0 90-180 0 0.0 0.0 0-180 2644 45.6 100.0 60˚ 1000 1500 30˚ Ordering information PTS7 2 Family Style Lamps Length Ballast Options 2 = 2 Lamp 24 = 24" 60 = 60" E81 = ELET8 120V T = Telescoping * 36 = 36" 96 = 96" E82 = ELE T8 277V Blank = Non-telescoping 48 = 48" 54 = 54" * * PTS7-2 lamp telescoping available in 42" with adjustment 42 = 42" * PTS7 = PTS7 of 27" to 42". Also available in 54" with adjustment of 39" to 54". Sample run accessories Example of a 21' 10 ¾" run of 1 light 277v PTS7 21' 10 ¾" Example of a 21' 10 ¾" run of 1 light 277v PTS7 (667cm) 21' 10 ¾" (667cm) 60" (152cm) 60" (152cm) 84" (213cm) 84" (213cm) 84" (213cm) 84" (213cm) Qty Catalog number Lighted telescoping Lighted unit telescoping unit X4 = 4 through wires X5 = 5 through wires X6 = 6 through wires T = Tandem switch Example of a 1 light pattern using IS and OS corners Example 10' of 2a¼" 1 light pattern using IS and OS corners (311cm) 10' 2 ¼" 9' 0"(311cm) (274cm) 9' 0" (274cm) 60" (152cm) 60" (152cm) 90º Inside corner 90º Inside corner 1 PTS7T148E82 2 PTS7184E82 1 PTS7160E82 1 PTS7EP Telescoping unit (3 places) Telescoping unit (3 places) 1 ½" (4cm) 1 ½" (4cm) 90º Outside corner 90º Outside corner Example of a 21' 10 ¾" run of 2 light 277v PTS7 21' 10 ¾" Example of a 21' 10 ¾" run of 2 light 277v PTS7 (667cm) 21' 10 ¾" (667cm) 24" (61cm) 24" (61cm) 36" (91cm) 36" (91cm) 48" (122cm) 48" (122cm) Qty Catalog number 1 PTS7T254E82 1 PTS7296E82 1 PTS7248E82 1 PTS7236E82 1 PTS7224E82 1 PTS7EP 96" (244cm) 96" (244cm) Lighted telescoping Lighted unit telescoping unit 14" (36cm) 14" (36cm) 48" (122cm) 48" (122cm) Top Qty Catalog number 1 PTS7C901 IS Corner 1 PTS7T148E82 Tele 1 PTS7160E82 Fixture 14" (36cm) 14" (36cm) Side Qty Catalog number 8' ½" (245cm) 8' ½" (245cm) 48" (122cm) 48" (122cm) 8' ½" (245cm) 8' ½" (245cm) 1 PTS7T148E82 Tele 1 PTS7148E82 Fixture 1 PTS7C900 OS Corner Bottom Qty Catalog number 1 PTS7T148E82 Tele 1 PTS7148E82 Fixture 1 PTS7EP End set 1 ½" (4cm) 1 ½" (4cm) Example of a 2 light pattern using IS and OS corners 9' 2 ¼" Example of a 2 light pattern using IS and OS corners (280cm) 9' 2 ¼" 8' 0"(280cm) (244cm) 8' 0" (244cm) 48" (122cm) 48" (122cm) 90º Inside corner 90º Inside corner Telescoping unit (3 places) Telescoping unit (3 places) 1 ½" (4cm) 1 ½" (4cm) 90º Outside corner 90º Outside corner 14" (36cm) 14" (36cm) 48" (122cm) 48" (122cm) Top Qty Catalog number 1 PTS7C901 IS Corner 1 PTS7T254E82 Tele 1 PTS7248E82 Fixture 14" (36cm) 14" (36cm) Side Qty Catalog number 8' ½" (245cm) 8' ½" (245cm) 48" (122cm) 48" (122cm) 1 ½" (4cm) 1 ½" (4cm) 8' ½" (245cm) 8' ½" (245cm) 1 PTS7T254E82 Tele 1 PTS7248E82 Fixture 1 PTS7C900 OS Corner Bottom Qty Catalog number 1 PTS7T254E82 Tele 1 PTS7248E82 Fixture 1 PTS7EP End set Comprehensive lighting catalog 7th Edition 4.103 Linear recessed and surface lighting – Professional PTS5 T5 lamps 2', 3', 4', 6' & 8' Architectural profiles PTS5-1 1 Light T5, high efficiency reflector 9 ⅜" (238mm) Candlepower Curve Distribution Zone Lumens %Lamp %Luminaire 0-90 1861 37.2 100.0 7" (178mm) 0.0 0-180 1861 37.2 100.0 5 ½" (140mm) 1800 Report no: ITL53559 Lumens: Cat no: Efficiency: 37.2% PTS51HS14 60˚ 900 Reference data Features Housing: Die formed 20 gauge pre-painted steel. Integral heavy gauge bulk-heads support housing and trim, permitting modules to be bolted together in continuous runs and to facilitate suspension. 90-180 0.0 0.0 5000 2700 Lamps: 1-F54T5 30˚ Module ordering information Lamping: Cross sectional one or two linear T5 fluorescent lamps. Provided by others. PTS5 Reflector: Precision parabolic roll-formed semispecular aluminum or precision die-formed CRS finished in a high reflective baked white powder coat. 1 Family Lamps PTS5 = PTS5 1 = 1 Lamp S = Standard O = Open H = HO S = S traight blade louver L = Lens Louver: Lift and shift straight blade louver constructed from die-formed aluminum and painted to match housing. Louver blades are 1" high on 1 1/8" centers (optional). Mounting: “J” Rail is first mounted to the wall and the modules connect to the rail for 1/4" wall adjustment. Modules are hung from suspension wires attached to the fixture bulkheads and the structure above. Shielding Voltage Length Options 1 = 120V 2 = 277V 3 = 347V D1 = Dimming 120V D2 = Dimming 277V D3 = Dimming 347V E1 = Emergency 120V E2 = Emergency 277V 2 = 2' 3 = 3' 4 = 4' 6 = 6' 8 = 8' Blank = No options A = Adjustable X4 = 4 through wires X5 = 5 through wires A4 = A justable 4 through wires justable 5 A5 = A through wires PTS5-2 2 Light T5, high efficiency reflector Electrical 9 ⅜" (238mm) Electronic ballast: Programmed start, 3 conductor, 12 gauge wire. Color-coded quick connectors allow easy connection for modular fixtures. Dimming: Advance Mark X, use Advance compatible two-wire control (no extra lead required). Type Candlepower Curve Distribution Zone Lumens %Lamp %Luminaire 0-90 3026 30.3 100.0 90-180 0.0 0.0 0-180 3026 30.3 7" (178mm) 0.0 Reference data Emergency battery pack: 450 Lumens @ 90 minimum. 4' fixture and longer only. Not available in adjustable fixtures. 5 ½" (140mm) 60˚ 2000 Report no: ITL53560 Lumens: Cat no: Efficiency: 30.3% PTS52HS14 1000 100.0 5000 3000 Lamps: 2-F54T5 30˚ Module ordering information PTS5 Sample Run 8' (244cm) 21'-10 ¾" (667cm) Fixture used at 3’ - 10 ¾" (119cm) 6' (183cm) 9'-3¼" (283cm) Fixture used at 3'-3¼" (100cm) 6' (183cm) Family Lamps PTS5 = PTS5 2 = 2 Lamp S = Standard O = Open H = HO S = S traight blade louver L = Lens 4' Three-Foot A¹ (122cm) 1' (30cm) Type Shielding Voltage Length Options 1 = 120V 2 = 277V 3 = 347V D1 = Dimming 120V D2 = Dimming 277V D3 = Dimming 347V E1 = Emergency 120V E2 = Emergency 277V 2 = 2' 3 = 3' 4 = 4' 6 = 6' 8 = 8' Blank = No options A = Adjustable AS = Adjustable Staggered S = Staggered X4 = 4 through wires X5 = 5 through wires A4 = A justable 4 through wires justable 5 A5 = A through wires S5 = Staggered 4 through wires S5 = Staggered 5 through wires B4 = Adjustable Staggered 4 through wires B5 = Adjustable Staggered 5 through wires Three-Foot A¹ 3' (91cm) Three-Foot A¹ Fixture used at 3'-10½" (118cm) 1¾" (4cm) For fixture using non-staggered lamps The four-foot adjustable fixture has a range of 48.75”(123.83cm) - 60”(152.40cm). The three-foot adjustable fixture has a range of 36.75”(93.35cm) - 48”(121.92cm). The two-foot adjustable fixture has a range of 24.75”(62.87cm) - 36”(91.44cm). 7'-10½" (240cm) 7'-10½" (240cm) Three-Foot A¹ 1¾" (4cm) 4' (122cm) Fixture used at 3'-10½" (118cm) 4.104 2 Philips Lightolier For fixture using staggered lamps The four-foot adjustable staggered fixture has a range of 51”(129.54cm) - 60”(152.40cm). The three-foot adjustable staggered fixture has a range of 39”(99.06cm) - 48”(121.92cm). The two-foot adjustable staggered fixture has a range of 27”(68.58cm) - 36”(91.44cm). For complete specification information visit www.lightolier.com Professional – Linear recessed and surface lighting PTS8 T8 lamps 2', 3', 4', 6' & 8' Architectural profiles PTS8-1 1 Light T8, high efficiency reflector 9 ⅜" (238mm) Candlepower Curve Distribution Zone Lumens %Lamp %Luminaire 0-90 1162 39.4 100.0 90-180 0 0.0 0-180 1162 39.4 7" (178mm) 0.0 Reference data 5 ½" (140mm) 60˚ 450 Features 100.0 Housing: Die formed 20 gauge pre-painted steel. Integral heavy gauge bulk-heads support housing and trim, permitting modules to be bolted together in continuous runs and to facilitate suspension. 900 Report no: ITL53557 Lumens: Cat no: Efficiency: 39.4% PTS81S14 2900 1350 Lamps: 1-F32T8 30˚ Module ordering information PTS8 Reflector: Precision parabolic roll-formed semi-specular aluminum. 1 Family Lamps Shielding Voltage Length Options PTS8 = PTS8 1 = 1 Light O = Open S = S traight blade louver L = Lens 1 = 120V 2 = 277V 3 = 347V D1 = Dimming 120V D2 = Dimming 277V D3 = Dimming 347V E1 = Emergency 120V E2 = Emergency 277V 2 = 2' 3 = 3' 4 = 4' 6 = 6' 8 = 8' Blank = No options A = Adjustable X4 = 4 through wires X5 = 5 through wires A4 = A justable 4 through wires justable 5 through wires A5 = A Louver: Lift and shift straight blade louver constructed from die-formed aluminum and painted to match housing. Louver blades are 1" high on 1 1/8" centers (optional). Mounting: “J” Rail is first mounted to the wall and the modules connect to the rail for 1/4" wall adjustment. Modules are hung from suspension wires attached to the fixture bulkheads and the structure above. Electrical PTS8-2 2 Light T8, high efficiency reflector 9 ⅜" (238mm) Candlepower Curve Distribution Zone Lumens %Lamp %Luminaire 0-90 1878 31.8 100.0 90-180 0 0.0 7" (178mm) 0-180 1878 31.8 650 0.0 5 ½" (140mm) 60˚ 100.0 Reference data Lumens: Cat no: Efficiency: 31.8% PTS82S14 2950 1950 Lamps: 2-F32T8 Electronic ballast: Programmed start, 3 conductor, 12 gauge wire. Color-coded quick connectors allow easy connection for modular fixtures. Dimming: Advance Mark X, use Advance compatible two-wire control (no extra lead required). Emergency battery pack: 450 Lumens @ 90 minimum. 4' fixture and longer only. Not available in adjustable fixtures. Ordering instructions 1300 Report no: ITL53558 Module ordering information PTS8 Lamping: Cross sectional one or two linear T8 fluorescent lamps. Provided by others. 30˚ 1. Order number of fixtures necessary to complete the run. 2. Order one end set per run. Runs with staggered lamp fixtures must end in adjustable staggered module. Contact factory for details. 2 Family Lamps Shielding Voltage Length Options PTS8 = PTS8 2 = 2 Light O = Open S = S traight blade louver L = Lens 1 = 120V 2 = 277V 3 = 347V D1 = Dimming 120V D2 = Dimming 277V D3 = Dimming 347V E1 = Emergency 120V E2 = Emergency 277V 2 = 2' 3 = 3' 4 = 4' 6 = 6' 8 = 8' Blank = No options A = Adjustable AS = A djustable staggered S = Staggered X4 = 4 through wires X5 = 5 through wires A4 = A justable 4 through wires justable 5 through wires A5 = A Adjustable fixtures in 2', 3' and 4's length only. Fixture will ship one foot longer than posted length. Staggered lamp fixtures will adjust down to 3" past posted length. Non-staggered lamp fixtures will adjust down to 1" past posted length. Area of adjustability is not lamped. S4 = S taggered 4 through wires S5 = S taggered 5 through wires B4 = Adjustable Staggered 4 through wires B5 = A justable Staggered 5 through wires Mounting accessories 12" (305mm) 90° Inside corner: PTS135INCL = Lens PTS135INCO = Open PTS135INCS = Straight blade 1 ¾" (45mm) 90° Outside corner: PTS90OTCL = Lens PTS90OTCO = Open PTS90OTCS = Straight blade 6 ¼" (159mm) 135° Inside corner: PTS90INCL = Lens PTS90INCO = Open PTS90INCS = Straight blade 2" (51mm) 135° Outside corner: PTS135OTCL = Lens PTS135OTCO = Open PTS135OTCS = Straight blade End cap set: PTSEP Comprehensive lighting catalog 7th Edition 4.105 Linear recessed and surface lighting – Professional GO2 Recessed high performance louver luminaires GO2 features a high reflectance flat white louver, and aluminum reflector system that are entirely fabricated with recyclable materials, finished with emission free powder coating, and packaged in recycled corrugated containers. Add to that, it is made in the USA, saving fuel from the factory to the job site, and it makes GO2 an environmentally friendly product. The flat white louver makes the luminaire low in brightness yet gives a broad light distribution that evenly illuminates all surfaces in the space, which creates a comfortable balanced brightness for the occupants. In addition it can provide illumination levels equal to the IESNA requirements, with a Visual Comfort Probability (VCP) that exceeds 70 at less than .6 watts per square foot. Replacing a typical 3 lamp parabolic with GO2 can save as much as 44% on your energy bill. The GO2 will not only meet your lighting level requirements, but also your LEED goals. The sharp cut-off of a traditional parabolic fixture casts dark shadows on the wall creating a cave effect. 4.106 Philips Lightolier For complete specification information visit www.lightolier.com Professional – Linear recessed and surface lighting GO2 2' x 4', 2' x 2' & 1' x 4' Recessed high performance louver luminaires GOS2G232UNVC5 Efficiency 85.9% Spacing ratio 1.7 Electronic ballast 24" (610mm) Size 6" (152mm) Static Example 2-T5 2-T5 2-T5HO 2' x 4' 2-T8 2" X 2-1/2" access plate with 2-T8 two K.O.s (7/8" dia.) 2-T8 GOS2G232 2400 Voltage Ballast 120 = 120V See page 4.107 277 = 277V UNV= 120-277V Options See page 4.107 and page 4.130 Size Lamp qty –type Static 2-T5 2-T5HO 2' x 2' 2-TT5 24" (610mm) 2-T8 2-T8U 1 ⅝" GOS2G217 Example Air supply slots (GOA Only)Series GO2 Lamp watts 5" (127mm) 14W 24W 40W 17W 32W UNV Candlepower Curve GOS2G214UNVPG GOS2G224UNVPG GOS2G2FTUNVPR GOS2G217UNVHI GOS2G22UUNVHI 23-7/8"Options Voltage Ballast (606mm) Direct/indirect 120 = 120V See page 4.107 See page 4.107 recessed static 277 = 277V and page 4.130 or air supply/return UNV= 2" X 2-1/2" access120-277V plate 15-11/16" 350 60˚ 1050 30˚ For slot grid ceiling change G to T. (e.g.: GOS2T217UNVHI) Candlepower Curve Efficiency 80.7% Spacing ratio 1.5 400 60˚ 1' x 4' 48" (1219mm) GOS1G132 Lamp watts Catalog no. 28W GOS1G228UNVPG 28W4-1/2" (114mm) GOS1G228UNVVY 54W GOS1G154UNVPG 2-3/4" (70mm) 32W GOS1G232UNVHI 11-1/2" 32W GOS1G232UNVV2 (292mm) UNV Air supply slots (GOA Only) GO2 Series Direct/indirect recessed static or air supply/return C2 Voltage Ballast 120 = 120V See page 4.107 277 = 277V UNV= 120-277V page 4.130 Ballast type <10THD <20THD Electronic T8 HI*, P2** Electronic T5 SO PG – Electronic TT5 40W IB*, PR** Bilevel step dim T8 V2 – SB Bilevel step dim T5 14W / 28W VY – Adv. Optainum low watt T8 C5 – Adv. Optainum stand. Watt T8 C2 – 1200 Drywall kit: C onversion kit for 2' x 4' unit: FK92X4. Conversion kit for 2' x 2' unit: FK92X2. Conversion kit for 1' x 4' unit: FK91X4. For drywall or plaster ceilings. Electrical/wiring options: For special wiring, fusing, electronic dimming ballasts, consult factory. 800 Ordering information 2-T5 2-T5 1-T5HO 2-T8 2-T8 • Manufactured in USA * Instant start. Input watts (120V) 30.2W Ballast factor 0.87 Lamp qty –type • 18 gauge steel hinges. ** Program start. Electronic ballast Size • Spring loaded latches. Options & accessories For air handling type fixture change S to A. (e.g.: GOA2G217UNVHI) Reference data 12" (305mm) • 94% reflectance Miro® reflector system. Ballast: Specify voltage (120, 277 or UNV) and type and add as suffix, e.g. UNVHI. (398mm) 5" 5 ¾" (127mm) (146mm) • 94% reflective flat white powder coated louver. • Construction to meet NYC Code or Chicago Plenum requirements is available. Catalog no. C2 GOS1G132UNVC2 • 80.7% efficient single lamp 32 watt T8 1' x 4' luminaire. • Black exterior for cooler ballast operating temperature. Efficiency 80.5% Spacing ratio 1.7 with two K.O.s (7/8" dia.) • 80.5% efficient two lamp 17 watt T8 2' x 2' luminaire. • One piece housing. 700 Type • 85.9% efficient two lamp 32 watt T8 2' x 4' luminaire. • 5" deep body. Input watts (120V) 30.2W Ballast factor 0.88 Ordering information • GO2 2X4 can provide 51 maintained footcandles at only .58 watts per square foot. • Built-in earthquake clips. Electronic ballast 24" (610mm) 30˚ For air handling type fixture change S to A. (e.g.: GOA2G232UNVHI) Reference data 5" (127mm) • GO2 evenly illuminates horizontal and vertical surfaces and is low in brightness. For slot grid ceiling change G to T. (e.g.: GOS2T232UNVH) C5 GOS2G217UNVC2 Example Features Catalog no. GOS2G228UNVPG GOS2G228UNVVY GOS2G254UNVPG GOS2G232UNVC5 GOS2G232UNVHI GOS2G232UNVV2 28W 28W 54W 32W 32W 32W UNV GO2 Series 48" (1219mm) Direct/indirect recessed static or air supply/return Static 60˚ 1600 Lamp qty –type Lamp Air supply slots (GOA Only) watts 39-1/4" (997mm) Type 800 Input watts (120V) 51.0W Ballast factor 0.78 Ordering information Type Candlepower Curve Reference data 5" (127mm) Fusing: Suffix: A (Internal fast-blow fusing). Suffix: C (Internal slow-blow fusing). 30˚ For air handling type fixture change S to A. (e.g.: GOA1G232UNVHI) For slot grid ceiling change G to T. (e.g.: GOS1T232UNVHI) Options See page 4.107 and page 4.130 Comprehensive lighting catalog 7th Edition 4.107 Linear recessed and surface lighting – Professional GO2 Retro 2' x 4' & 2' x 2' Retro fit recessed luminaires GO2 Retro features a flat white louver and a unique power tray that can be used to convert most installations of 2' x 4' or 2' x 2' parabolic or specification grade lens troffers, that are at least 4 3/8" deep, to state of the art, energy saving GREEN FIXTURES. GO2 Retro is over 80% efficient with a broad light distribution that will illuminate both horizontal and vertical surfaces, creating a comfortable balanced brightness. Features • GO2 Retro can be used to convert most 2' x 4' and 2' x 2' parabolic or specification grade lens troffers into energy saving luminaires. GOR2G232UNVC5 Candlepower Curve Reference data • GO2 Retro evenly illuminates horizontal and vertical surfaces and is low in brightness. Efficiency 84.5% Spacing ratio 1.5 • GO2 Retro is ideal for those areas where you would like to have a minimum of down time such as retail spaces and schools. Electronic ballast 650 60˚ Input watts (120V) 53.0W Ballast factor 0.77 • Manufactured in USA 1300 GO2 Retro 2' x 4' GO2 Retro 2' x 2' • 12 Cell 95% reflective flat white powder coated louver. • 6 Cell 95% reflective flat white powder coated louver. • 84.5% efficient 32W T8. • 80.6% efficient 17W T8. Ordering information • 1.5 space mounting ratio. • 1.5 space mounting ratio. Type Options & accessories page 4.130 Retro fit Ballast: Specify voltage (120, 277 or UNV) and type and add as suffix, e.g. UNVHI. Ballast type <10THD <20THD HI*, P2** Electronic T8 1950 PG – Bilevel step dim T8 V2 – Bilevel step dim T5 14W / 28W VY – Adv. Optainum low watt T8 C5 – Adv. Optainum stand. Watt T8 C2 – * Instant start. Lamp qty –type 2-T5 2-T5HO 2-T8 2' x 4' Lamp watts Catalog no. GOR2G228UNVPG GOR2G254UNVPG GOR2G232UNVHI 28W 54W 32W Available with EM Pack Consult factory Example SO Electronic T5 Size 30˚ GOR2G232 UNV GO2 Retro Direct/indirect Retro fit recessed HI Voltage Ballast 120 = 120V See page 4.108 277 = 277V UNV= 120-277V GOR2G217UNVC2 A Options See page 4.108 and page 4.130 Candlepower Curve Reference data ** Program start. Efficiency 80.6% Spacing ratio 1.5 Dimensions are clearance required in fixture for GO2 Retro to fit Electronic ballast 300 60˚ Input watts (120V) 30.8W Ballast factor 0.88 20 5¹6" (516mm) min. 600 4 ⅜" (111mm) ¾" (19mm) 20 ⅞" (530mm) min. 22 ¾" (578mm) min. 3" (76mm) 900 Ordering information Type ¾" (19mm) min. 46 ¼" (1175mm) 2 x 4 22 ¼" (565mm) 2 x 2 Retro fit Size Lamp qty –type 2' x 2' 2-T5 2-T5HO 2-T8 GOR2G217 GO2 Retro Direct/indirect Retro Fit Recessed Philips Lightolier Lamp watts 14W 24W 17W Catalog no. GOR2G214UNVPG GOR2G224UNVPG GOR2G217UNVHI 2 x 2 Not Available with Emergency Pack Example 4.108 30˚ UNV HI Voltage Ballast 120 = 120V See page 4.108 277 = 277V UNV= 120-277V A Options See page 4.108 and page 4.130 For complete specification information visit www.lightolier.com Professional – Linear recessed and surface lighting GO2 easy installation Retro fit recessed luminaires Retrofitting with GO2 Retro as opposed to installing new fixtures is ideal for those areas where you would like to have a minimum of down time such as retail spaces or schools. Step 1 Step 2 The first step in installation, after making sure power to fixture is disconnected, is to remove all existing components of the previous fixture, leaving only the body. Place the GO2 Retro end adaptors between the base of the fixture and the T-Bar. Secure the GO2 Retro End Adaptors in place with the supplied tech screws (4). Hang GO2 Retro power tray on tab and slot as shown above. Using the ballast disconnect supplied (accepts up to 12 gauge wire), make power connections and ground connection to body. Step 3 Step 4 Lift GO2 Retro power tray into position. Slide GO2 Retro power tray into brackets on end adaptors. Slide the telescoping end of the GO2 Retro power tray into place, resting on the end adaptors. Tighten the integrated white thumb screws of the GO2 Retro power tray securing it in place. Step 5 Insert the GO2 Retro louver pins into the louver slots of the GO2 Retro end adaptors and close. The installation of the GO2 Retro is complete. Comprehensive lighting catalog 7th Edition 4.109 Linear recessed and surface lighting – Professional Vision Smart 2' x 4' 4" Parabolic louver recessed air handling luminaires Vision Smart 2' x 4' Parabolics meet criteria of IES RP-1 and RP-24. Features • VR unit meets IES RP24 and RP1 recommended (basic) criteria for lighting VDT areas. VRA2G12LS232UNVHI Efficiency 70.9% Spacing ratio 1.8 6" (152mm) • Candelas at Nadir (0°), 1510 on 2-lamp VR. Electronic ballast • Semi-specular low iridescence pre-anodized louver in VR model. Max average brightness • Only 6" deep. 55° 1701cd/m2 65° 345cd/m2 75° 61cd/m2 85° 36cd/m2 • Earthquake clips included. • Protective film dust guard. • UL-Listed twin knockout access plate. Cell • Metal gauge/construction to meet NYC 8Code or Chicago Plenum is available. Ballast: Specify voltage (120, 277 or UNV) and type and add as suffix, e.g. UNVHI. 9 Cell Ballast type <10THD <20THD HI*, P2** – 1600 2400 30˚ Ordering information page 4.130 LOL T8 Dimming 60˚ 12 Cell 12 Cell Louver finish: Low iridescence semi-specular is standard. Consult factory for other finishes. Electronic T8 800 Input watts (120V) 62.0W LER 60.4 24" (610mm) • Concealed spring-loaded latch/hinge can be opened either side. Options & accessories Candlepower Curve Reference data SO* PS * Instant start. Type Size Air handling 2' x 4' 12 Cell Example Cells Lamp qty –Type 12 2-T8 16 Cell 18 Cell VRA2G12LS232 Vision Smart 4" Precision contoured pre-anodized aluminum parabolic louver Exposed T-Grid Exposed Slot-T or concealed T-Grid VRA2G12LS232 VRA2T12LS232 UNV 24 Cell HI 32 Cell Voltage Ballast 120 = 120V See page 4.110 277 = 277V UNV= 120-277V ACS4 Options See page 4.110 and page 4.130 (Elec. T8 ballast only) ** Program start. Consult factory for other wattages. Electrical/wiring options: For special wiring, fusing, electronic dimming ballasts, consult factory. Air closure strips: ACS4 (factory installed). ACS4 CSP (field installed). Chicago Plenum: Suffix: C. For products that meet Chicago Plenum requirements. Fusing: Suffix: A (Internal fast-blow fusing). Suffix: C (Internal slow-blow fusing). Note: For concealed spline, plaster or drywall ceiling, use “G” type fixtures with either S2X4F Kit (see Folio OA-30-30), or Drywall kit, FK92X4 (see Folio OA30-10). 4.110 Philips Lightolier For complete specification information visit www.lightolier.com Professional – Linear recessed and surface lighting Vision Smart 2' x 4' 4" Parabolic louver recessed air handling luminaires Vision Smart 2' x 4' Parabolics meet the criteria of IES RP-1 and RP-24. VRA2G18LP332UNVH3 Efficiency 64.5% Spacing ratio 1.5 6" (152mm) 12 Cell Candlepower Curve Reference data Electronic ballast 12 Cell Max average brightness 55° 2681cd/m2 65° 304cd/m2 75° 147cd/m2 85° 0cd/m2 12 Cell 16 Cell 18 Cell Size Air handling 2' x 4' Example Cells Lamp qty –type 18 3-T8 VRA2G18LP332 Vision Smart 4" Precision contoured pre-anodized aluminum parabolic louver 30˚ • Earthquake clips included. • Protective film dust guard. • Metal gauge/construction to meet NYC Code or Chicago Plenum is available. Exposed Slot-T or concealed T-Grid VRA2G18LP332 VRA2T18LP332 H3 Voltage Ballast 120 = 120V See page 4.111 277 = 277V UNV= 120-277V (Elec. T8 ballast only) • Concealed spring-loaded latch/hinge can be opened either side. • UL-Listed twin knockout access plate. Exposed T-Grid UNV • Semi-specular low iridescence pre-anodized louver in VR model. • Only 6" deep. 3000 Ordering information Type 60˚ 2000 32 Cell 24 Cell • VR unit meets IES RP24 and RP1 recommended (basic) criteria for lighting VDT areas. • Candelas at Nadir (0°), 1510 on 2-lamp VR. 1000 Input watts (120V) 85.0W LER 60.1 24" (610mm) Features ACS4 Options See page 4.111 and page 4.130 Options & accessories page 4.130 Louver finish: Low iridescence semi-specular is standard. Consult factory for other finishes. Ballast: Specify voltage (120, 277 or UNV) and type and add as suffix, e.g. UNVHI. Ballast type <10THD <20THD Electronic T8 HI*, P2** 1 - 3 Lamp Elec. T8 H3*, P3** O3* LOL T8 Dimming – SO* PS * Instant start. ** Program start. Consult factory for other wattages. Electrical/wiring options: For special wiring, fusing, electronic dimming ballasts, consult factory. Air closure strips: ACS4 (factory installed). ACS4 CSP (field installed). Chicago Plenum: Suffix: C. For products that meet Chicago Plenum requirements. Fusing: Suffix: A (Internal fast-blow fusing). Suffix: C (Internal slow-blow fusing). Note: For concealed spline, plaster or drywall ceiling, use “G” type fixtures with either S2X4F Kit (see Folio OA-30-30), or Drywall kit, FK92X4 (see Folio OA30-10). Comprehensive lighting catalog 7th Edition 4.111 Linear recessed and surface lighting – Professional Vision Smart 2' x 2' 4" Parabolic louver recessed air handling luminaires Vision Smart VR architecturally symmetrical 2' x 2' Parabolics meet the criteria of IES RP-1 and RP-24. VRA2G16LV2FT120SB Features • Candelas at Nadir (0°), 1224 on 2-lamp VR. 8 Celllouver in • Semi-specular low iridescence pre-anodized 12 Cell 12 Cell Efficiency 52.2% Spacing ratio 1.8 6" (152mm) VR models. Candlepower Curve Reference data 800 Electronic ballast • Concealed spring-loaded latch/hinge can be opened either side. • Only 6" deep. • Louver frame with integral positive light stop. Max average brightness • Earthquake clips included. 55° 1130cd/m2 65° 267cd/m2 2 32 Cell 75° 121cd/m • Protective film dust guard. • UL-Listed twin knockout access plate. 9 Cell 12 Cell 16 Cell 18 Cell Ordering information Options & accessories Type Size Air handling 2' x 2' page 4.130 Louver finish: Low iridescence semi-specular is standard. Consult factory for other finishes. Ballast: Specify voltage (120, 277 or UNV) and type and add as suffix, e.g. UNVPR. Ballast type <10THD <20THD SB* LOL TT5 Dimming – PB Cells Lamp qty –type 16 2-TT5 VRA2G16LV2FT Example IB*, PR** 24 Cell 1600 2400 30˚ 85° 72cd/m2 • Metal gauge/construction to meet NYC Code or Chicago Plenum is available. 1 - 2 Lamp Elec. TT5 40W 60˚ Input watts (120V) 74.0W LER 39.9 24" (610mm) Vision Smart 4" Precision contoured pre-anodized aluminum parabolic louver Exposed T-Grid Exposed Slot-T or concealed T-Grid VRA2G16LV2FT VRA2T16LV2FT 120 SB Voltage Ballast 120 = 120V See page 4.112 277 = 277V UNV= 120-277V ACS2 Options See page 4.112 and page 4.130 (Elec. T8 or TT5 ballast only) * Instant start. ** Program start. Candlepower Curve Consult factory for other wattages. Electrical/wiring options: For special wiring, fusing, electronic dimming ballasts, consult factory. Air closure strips: ACS2 (factory installed). ACS2 CSP (field installed). Fusing: Suffix: A (Internal fast-blow fusing). Suffix: C (Internal slow-blow fusing). Chicago Plenum: Suffix: C. For products that meet Chicago Plenum requirements. 600 60˚ 1200 1800 30˚ Note: For concealed spline, plaster or drywall ceiling, use “G” type fixtures with either S2X2F Kit (see Folio OA-30-30), or Drywall kit, FK92X2 (see Folio OA30-10). 4.112 Philips Lightolier For complete specification information visit www.lightolier.com 1600 2400 Professional – Linear recessed and surface lighting 30˚ Vision Smart 2' x 2' 4" Parabolic louver recessed air handling luminaires Vision Smart VR architecturally symmetrical 2' x 2' Parabolics meet the criteria of IES RP-1 and RP-24. VRA2G9LP317UNVH3 8 Cell 12 Cell Candlepower Curve Reference data 6" (152mm) 12 Cell Efficiency 62.7% Spacing ratio 1.4 1200 Max average brightness 9 Cell 12 Cell 16 Cell 55° 2203cd/m2 65° 238cd/m2 2 18 Cell 75° 91cd/m 24 Cell 2' x 2' Cells Lamp qty –type Exposed T-Grid Exposed Slot-T or concealed T-Grid 9 3-T8 VRA2G9LP317 VRA2T9LP317 VRA2G9LP317 Example Vision Smart 4" Precision contoured pre-anodized aluminum parabolic louver UNV H3 Voltage Ballast 120 = 120V See page 4.113 277 = 277V UNV= 120-277V (Elec. T8 ballast only) • Only 6" deep. 32 Cell 30˚ • Earthquake clips included. • Protective film dust guard. • UL-Listed twin knockout access plate. Ordering information Air handling • Semi-specular low iridescence pre-anodized louver in VR models. • Louver frame with integral positive light stop. 1800 85° 0cd/m2 Size • VR 9 cell unit meets IES RP24 and RP1 recommended (basic) criteria for lighting VDT areas. • Concealed spring-loaded latch/hinge can be opened either side. Input watts (120V) 47.0W LER 50.4 24" (610mm) Type 60˚ 600 Electronic ballast Features ACS2 Options See page 4.113 and page 4.130 • Metal gauge/construction to meet NYC Code or Chicago Plenum is available. Options & accessories page 4.130 Louver finish: Low iridescence semi-specular is standard. Consult factory for other finishes. Ballast: Specify voltage (120, 277 or UNV) and type and add as suffix, e.g. UNVHI. Ballast type <10THD <20THD Electronic T8 HI*, P2** 1 - 3 Lamp Elec. T8 H3*, P3** O3* LOL T8 Dimming – SO* PS * Instant start. ** Program start. Consult factory for other wattages. Electrical/wiring options: For special wiring, fusing, electronic dimming ballasts, consult factory. Air closure strips: ACS4 (factory installed). ACS4 CSP (field installed). Fusing: Suffix: A (Internal fast-blow fusing). Suffix: C (Internal slow-blow fusing). Chicago Plenum: Suffix: C. For products that meet Chicago Plenum requirements. Note: For concealed spline, plaster or drywall ceiling, use “G” type fixtures with either S2X2F KIT (see Folio OA-30-30), or DRYWALL KIT, FK92X2 (see Folio OA30-10). Comprehensive lighting catalog 7th Edition 4.113 Linear recessed and surface lighting – Professional Vision Smart 2' x 2' 4" Parabolic louver recessed air handling luminaires Vision Smart architecturally symmetrical 2' x 2' VR Parabolics meet the criteria of IES RP-1 and RP‑24. The VR Series is best suited wherever use of VDT’s is occasional or nonintensive. Features • VR units meet IES RP24 and RP1 recommended (basic) criteria for lighting VDT areas. VRA2G9LS26UUNVHI 8 Cell 12 Cell • Only 6" deep. 6" (152mm) • Louver frame with integral positive light stop. 9 Cell • Protective Film dust guard. 12 Cell 16 Cell 55° 3272cd/m2 65° 357cd/m2 2 18 Cell 75° 130cd/m 24 Cell 1650 32 Cell 30˚ 85° 38cd/m2 • UL-Listed twin knockout access plate. Ordering information • Metal gauge/construction to meet NYC Code or Chicago Plenum is available. page 4.130 Louver finish: Low iridescence semi-specular is standard. Consult factory for other finishes. Ballast: Specify voltage (120, 277 or UNV) and type and add as suffix, e.g. UNVHI. Type Size Air handling 2' x 2' Example Cells Lamp qty –type Exposed T-Grid Exposed Slot-T or concealed T-Grid 9 2-T8U6 VRA2G9LS26U VRA2T9LS26U VRA2G9LS26U UNV Vision Smart 4" Precision contoured pre-anodized aluminum parabolic louver Ballast type <10THD <20THD HI*, P2** 1100 Max average brightness • Earthquake clips included. 60˚ 550 Input watts (120V) 60.0W LER 50.0 24" (610mm) • Concealed spring-loaded latch/hinge can be opened either side. Electronic T8 Efficiency 57.1% Spacing ratio 1.3 Electronic ballast • Semi-specular low iridescence pre-anodized louver is standard on VR models. Options & accessories Candlepower Curve Reference data 12 Cell SO* LOL T8 Dimming – PS HI Voltage Ballast 120 = 120V See page 4.114 277 = 277V UNV= 120-277V ACS2 Options See page 4.114 and page 4.130 (Elect. Ballast only) * Instant start. ** Program start. Consult factory for other wattages. Electrical/wiring options: For special wiring, 8 Cell fusing, electronic dimming ballasts, consult factory. VRA2G16LS26UUNVHI 12 Cell 12 Cell Efficiency 51.7% Spacing ratio 1.2 6" (152mm) Air closure strips: ACS2 (factory installed). ACS2 CSP (field installed). Candlepower Curve Reference data Electronic ballast Chicago Plenum: Suffix: C. For products that meet Chicago Plenum requirements. 650 Max average brightness Note: For concealed spline, plaster or drywall ceiling, use “G” type fixtures with either S2X2F Kit (see Folio OA-30-30), or Drywall 9 Cell 12 Cell kit, FK92X2 (see Folio OA30-10). 16 Cell 60˚ Input watts (120V) 60.0W LER 45.4 24" (610mm) 18 Cell 24 Cell 55° 1619cd/m2 65° 293cd/m2 2 32 Cell 75° 104cd/m 1300 1950 30˚ 85° 77cd/m2 Ordering information Type Size Air handling 2' x 2' Example Cells Lamp qty –type 16 2-T8U6 VRA2G9LS26U Vision Smart 4" Precision contoured pre-anodized aluminum parabolic louver 4.114 Philips Lightolier Exposed T-Grid Exposed Slot-T or concealed T-Grid VRA2G16LS26U VRA2T16LS26U UNV HI Voltage Ballast 120 = 120V See page 4.114 277 = 277V UNV= 120-277V ACS2 Options See page 4.114 and page 4.130 (Elect. Ballast only) For complete specification information visit www.lightolier.com Professional – Linear recessed and surface lighting Vision Smart 2' x 2' 4" Parabolic louver recessed air handling luminaires Vision Smart architecturally symmetrical 2' x 2' VR Parabolics meet the criteria of IES RP-1 and RP‑24. The VR Series is best suited wherever use of VDT’s is occasional or nonintensive. VRA2G9LP32UUNVH3 8 Cell Candlepower Curve Reference data 12 Cell 12 Cell 6" (152mm) Efficiency 56.7% Spacing ratio 1.4 60˚ 1400 Input watts (120V) 83.0W LER 57.0 Louver finish is low iridescence semi-specular. 9 Cell 12 Cell 16 Cell • Louver frame with integral positive light stop. 24 Cell 4200 32 Cell 30˚ 85° 115cd/m2 Size Air handling 2' x 2' Example Cells Lamp qty –type 3-T8U1.6 3-TT5 9 VRA2G9LP32U Exposed T-Grid Exposed Slot-T or concealed T-Grid VRA2G9LP32U VRA2G9LP3FT VRA2T9LP32U VRA2T9LP3FT UNV Vision Smart 4" Precision contoured pre-anodized aluminum parabolic louver H3 8 Cell Candlepower Curve 24" (610mm) 12 Cell 16 Cell 18 Cell 32 Cell 4500 12 Cells Ordering information Size Air handling 2' x 2' Example Cells 12 Lamp qty –type 3-T8U1.6 3-TT5 VRA2G12PP3FT Vision Smart 4" Precision contoured pre-anodized aluminum parabolic louver Exposed T-Grid Exposed Slot-T or concealed T-Grid VRA2G12PP32U VRA2G12PP3FT VRA2T12PP32U VRA2T12PP3FT 120 X3 Voltage Ballast 120 = 120V See page 4.115 277 = 277V UNV= 120-277V H3*, P3** O3* SO* 1 & 2 Lamp elec. TT5 40W IB*, PR** SB* 1 - 3 Lamp elec. TT5 40W I3* X3* LOL T8 Dimming – PS LOL TT5 Dimming – PB Consult factory for other wattages. Electrical/wiring options: For special wiring, fusing, electronic dimming ballasts, consult factory. Air closure strips: ACS4 (factory installed). ACS4 CSP (field installed). 85° 38cd/m2 Type 60˚ 3000 Max average brightness 55° 1151cd/m2 65° 71cd/m2 2 24 Cell 75° 52cd/m HI*, P2** 1 - 3 Lamp elec. T8 ** Program start. 1500 Input watts (120V) 83.0W LER 53.0 Louver finish is low iridescence specular. Electronic T8 * Instant start. Electronic ballast 9 Cell Ballast type <10THD <20THD Options See page 4.115 and page 4.130 Efficiency 55.5% Spacing ratio 1.4 6" (152mm) page 4.130 Ballast: Specify voltage (120, 277 or UNV) and type and add as suffix, e.g. UNVHI. Reference data 12 Cell 12 Cell Options & accessories Louver finish: Low iridescence semi-specular is standard. Consult factory for other finishes. (Elect. Ballast only) VRA2G12PP32UUNVH3 • Protective Film dust guard. • Metal gauge/construction to meet NYC Code or Chicago Plenum is available. ACS2 Voltage Ballast 120 = 120V See page 4.115 277 = 277V UNV= 120-277V • Earthquake clips included. • UL-Listed twin knockout access plate. 9 Cells Ordering information Type • Semi-specular low iridescence pre-anodized louver is standard on VR models. • Concealed spring-loaded latch/hinge can be opened either side. 2800 Max average brightness 55° 4605cd/m2 65° 484cd/m2 2 18 Cell 75° 181cd/m • VR units meet IES RP24 and RP1 recommended (basic) criteria for lighting VDT areas. • Only 6" deep. Electronic ballast 24" (610mm) Features 30˚ Chicago Plenum: Suffix: C. For products that meet Chicago Plenum requirements. Note: For concealed spline, plaster or drywall ceiling, use “G” type fixtures with either S2X2F KIT (see Folio OA-30-30), or DRYWALL KIT, FK92X2 (see Folio OA30-10). ACS2 Options See page 4.115 and page 4.130 (Elect. Ballast only) Comprehensive lighting catalog 7th Edition 4.115 Linear recessed and surface lighting – Professional Vision Smart 1' x 4' 3" Parabolic louver recessed air supply/return/static luminaires Vision Smart (VR) luminaires 1 lamp 8 cell, 2 lamp 12 cell comply with the Basic Criteria of RP-1 (formerly RP-24). Features • Meets IES RP-1 recommended (minimum requirements) for lighting VDT areas (VR 1 lamp 8 and 12 cell). VRA1G8LW132UNVHI Efficiency 67.9% Spacing ratio 1.9 5 ¾" (146mm) • Semi-specular low iridescence pre-anodized louver. Candlepower Curve Reference data Electronic ballast • Vertical grain on louver eliminates reflected lamp images on cross baffle. 200 60˚ Input watts (120V) 30.0W • Louver frame with positive light stop. Max average brightness 12" (305mm) 65° 837cd/m2 75° 82cd/m2 85° 0cd/m2 • Spring-loaded latches (self centering). • Black housing exterior for cooler ballast operating temperature. 400 800 30˚ • Built-in earthquake clip • UL-Listed twin knockout access plate. • Metal gauge/construction to meet NYC Code or Chicago Plenum is available. 8 Cell 8 Cell 12 Cell 12 Cell 12 Cell 12 Cell • Turned-in edges for safe handling. Options & accessories page 4.130 Ordering information Louver finish: Low iridescence semi-specular is standard. Consult factory for other finishes. Type Ballast: Specify voltage (120, 277 or UNV) and type and add as suffix, e.g. UNVHI. Ballast type <10THD <20THD Electronic T8 HI*, P2** LOL T8 Dimming – Size Static 1' x 4' * Instant start. ** Program start. Consult factory for other wattages. Drywall kit: Catalog no. FK91X4 with “G” type fixtures for drywall or plaster ceilings. Electrical/wiring options: For special wiring, fusing, electronic dimming ballasts, consult factory. Plaster frame: For type F troffers, order plaster frames separately. Catalog no. PF14 for 1' x 4' troffer. Lamp qty –type Example 8 12 8 12 1-T8 1-T8 2-T8 2-T8 VRA1G8LW132 Vision Smart 3" Parabolic Flanged for dry or plaster Exposed T-Grid 8 1-T8 12 12 Cell1-T8 12 Cell 16 Cell Air9 Cell handling 9 Cell 1' x 4' 8 2-T8 12 2-T8 SO* PS Cells Slot-T or Concealed T VRA1G8LW132 VRA1F8LW132 VRA1T8LW132 VRA1G12LW132 VRA1F12LW132 VRA1T12LW132 16 Cell 18 Cell 18 Cell 24 Cell 24 Cell 32 Cell 32 Cell VRA1G8LW232 VRA1F8LW232 VRA1T8LW232 VRA1G12LW232 VRA1F12LW232 VRA1T12LW232 VRS1G8LW132 VRS1G12LW132 VRS1G8LW232 VRS1G12LW232 UNV VRS1F8LW132 VRS1F12LW132 VRS1F8LW232 VRS1F12LW232 VRS1T8LW132 VRS1T12LW132 VRS1T8LW232 VRS1T12LW232 HI Voltage Ballast 120 = 120V See page 4.116 277 = 277V UNV= 120-277V Options See page 4.116 and page 4.130 (Elect. Ballast only) Continuous row installation: For “F” type fixtures, half-width flanges are required between fixtures. Catalog no. 1FCTRIM (each joint). Air closure strips: ACS4 (factory installed). ACS4 CSP (field installed). Fusing: Suffix: A (Internal fast-blow fusing). Suffix: C (Internal slow-blow fusing). Chicago Plenum: Suffix: C. For products that meet Chicago Plenum requirements. 4.116 Philips Lightolier For complete specification information visit www.lightolier.com Specification – Linear recessed and surface lighting Stacklyte 1' x 4' 3" Parabolic louver recessed air supply/return/static luminaires Stacklyte (STA) is excellent for lighting library bookshelves with 97.5% of the fixture distribution in the 90° zone. STA1G8LR132UNVHI Candlepower Curve Features • Semi-specular low iridescence pre-anodized louver. • Vertical grain on louver eliminates reflected lamp images on cross baffle. 5 ¾" (146mm) 400 60˚ • Louver frame with positive light stop. • Spring-loaded latches (self centering). 8 Cell 12" (305mm) 8 Cell 12 Cell • Black housing exterior for cooler ballast operating temperature. 12 Cell 12 Cell 80012 Cell • Built-in earthquake clip 1200 5 ¾" (146mm) 9 Cell 9 Cell 12 Cell 12 Cell 16 Cell 16 Cell 18 Cell Ordering information Type Air handling Static Example Cells 1' x 4' 8 12 8 12 1' x 4' 8 12 8 12 Size STA1G8LR132 Stacklyte 3" Parabolic • UL-Listed twin knockout access plate. • Metal gauge/construction to meet NYC Code or Chicago Plenum is available. • Turned-in edges for safe handling. 12" (305mm) Lamp qty –type 30˚ Exposed T-Grid Flanged for dry or plaster Slot-T or Concealed T 1-T8 1-T8 2-T8 2-T8 STA1G8LR132 STA1G12LR132 STA1G8LR232 STA1G12LR232 STA1F8LR132 STA1F12LR132 STA1F8LR232 STA1F12LR232 STA1T8LR132 STA1T12LR132 STA1T8LR232 STA1T12LR232 1-T8 1-T8 2-T8 2-T8 STS1G8LR132 STS1G12LR132 STS1G8LR232 STS1G12LR232 STS1F8LR132 STS1F12LR132 STS1F8LR232 STS1F12LR232 STS1T8LR132 STS1T12LR132 STS1T8LR232 STS1T12LR232 UNV HI Voltage Ballast 120 = 120V See page 4.117 277 = 277V UNV= 120-277V (Elect. Ballast only) Vertical footcandles on book shelves 1' 2' 3' 4' Ceiling 1 48 48 49 48 48 48 49 48 48 2 36 36 36 36 36 36 36 36 36 3 28 28 28 28 28 28 28 28 28 4 24 24 24 24 24 24 24 24 24 5 21 21 21 21 21 21 21 21 21 6 18 18 18 18 18 18 18 18 18 7 16 16 16 16 16 16 16 16 16 8 16 16 16 16 16 16 16 16 16 9 15 15 15 15 15 15 15 15 15 10 14 14 14 14 14 14 14 14 14 11 12 12 12 12 12 12 12 12 12 12 10 10 10 10 10 10 10 10 10 Floor Options See page 4.117 and page 4.130 Options & accessories 18 Cell 24 Cell 24 Cell 32 Cell page 4.130 32 Cell Louver finish: Low iridescence semi-specular is standard. Consult factory for other finishes. Ballast: Specify voltage (120, 277 or UNV) and type and add as suffix, e.g. UNVHI. Ballast type <10THD <20THD Electronic T8 HI*, P2** LOL T8 Dimming – SO* PS * Instant start. ** Program start. Consult factory for other wattages. Drywall kit: Catalog no. FK91X4 with “G” type fixtures for drywall or plaster ceilings. Electrical/wiring options: For special wiring, fusing, electronic dimming ballasts, consult factory. Plaster frame: For type F troffers, order plaster frames separately. Catalog no. PF14 for 1' x 4' troffer. Continuous row installation: For “F” type fixtures, half-width flanges are required between fixtures. Catalog no. 1FCTRIM (each joint). Air closure strips: ACS4 (factory installed). ACS4 CSP (field installed). Fusing: Suffix: A (Internal fast-blow fusing). Suffix: C (Internal slow-blow fusing). Chicago Plenum: Suffix: C. For products that meet Chicago Plenum requirements. 36" bookshelf aisle width Comprehensive lighting catalog 7th Edition 4.117 Linear recessed and surface lighting – Specification Deepcel Plus 2' x 4' 3" Parabolic louver recessed air return/static luminaires Philips Lightolier Deepcel Plus is the industry standard 3" parabolic louver troffer with features that offer value above the industry standard. DPA2G18LP332UNVH3 Features Efficiency 77.7% Spacing ratio 1.6 5" (127mm) • 5" deep body. 8 Cellcompartments. 8 Cell 12 Cell 12 Cell • Individual lamp Candlepower Curve Reference data 12 Cell 12 Cell Electronic ballast 24" (610mm) • 77.7% efficient, 3 lamp 18 cell. 60˚ 900 Input watts (120V) 85.9W Luminaire eff. (LER) 68.6 • Clean contoured interior. 1800 • Eyeleted heat removal vents in fixture ends. • One piece housing. • Black exterior for cooler ballast operating temperature. 2700 30˚ • Hemmed over side rails for safe handling. • Built-in earthquake clips. 9 Cell 9 Cell 12 Cell 12 Cell 16 Cell 16 Cell • Pre-anodized aluminum parabolic louver. 18 Cell 18 Cell Ordering information • Vertical grain louver eliminates reflected lamp images on cross baffle. Type • Spring-loaded rooster head latches. Size • 18 gauge steel hinges. Air handling Static • Louver frame with integral positive light stop. • Louver has protective film dust guard. Options & accessories Exposed T-Grid Flanged for dry or plaster Slot-T or Concealed T 2' x 4' 18 24 3-T8 DPA2G18LP332 DPA2G24LP332 DPA2F18LP332 DPA2F24LP332 DPA2T18LP332 DPA2T24LP332 2' x 4' 18 24 3-T8 DPS2G18LP332 DPS2G24LP332 DPS2F18LP332 DPS2F24LP332 DPS2T18LP332 DPS2T24LP332 Deepcel Plus 3" Precision contoured pre-anodized aluminum parabolic louver Ballast type <10THD <20THD Electronic T8 HI*, P2** SO* 1 - 3 Lamp elec. T8 H3*, P3** O3* 1 - 4 Lamp elec. T8 H4*, P4** O4* LOL T8 Dimming 8 Cell Lamp qty –type DPA2G18LP332 Example Ballast: Specify voltage (120, 277 or UNV) and type and add as suffix, e.g. UNVHI. ** Program start. Cells page 4.130 Louver finish: Low iridescence semi-specular is standard. Consult factory for other finishes. * Instant start. 32 Cell 32 Cell 24 Cell 24 Cell H3 ACS4 Options See page 4.118 and page 4.130 (Elec. T8 ballast only) DPA2G18LS332UNVH3 – PS 12 Cell UNV Voltage Ballast 120 = 120V See page 4.118 277 = 277V UNV= 120-277V Candlepower Curve Reference data Efficiency 77.6% Spacing ratio 1.6 5" (127mm) 12 Cell Electronic ballast 24" (610mm) Consult factory for other wattages. 850 1700 Drywall kit: Conversion kit for 2' x 4' unit: FK92X4. Electrical/wiring options: For special wiring, fusing, electronic dimming ballasts, consult factory. Plaster frame: For type F troffers, order plaster frames separately. Catalog no. PF24 for 2' x 4' troffer. 9 Cell 12 Cell Continuous row installation: For “F” type fixtures, half-width flanges are required between fixtures. Catalog no. 2FCTRIM (each joint). 2550 16 Cell 18 Cell 32 Cell 24 Cell Cells Lamp qty –type 2' x 4' 18 2' x 4' 18 Type Size Chicago Plenum: Suffix: C. For products that meet Chicago Plenum requirements. Air handling NYC code: Change DP to DY. Static Example Exposed T-Grid Flanged for dry or plaster Slot-T or Concealed T 3-T8 4-T8 DPA2G18LS332 DPA2F18LS432 DPA2F18LS332 DPA2F18LS432 DPA2T18LS332 DPA2T18LS432 3-T8 4-T8 DPS2G18LS332 DPS2G18LS432 DPS2F18LS332 DPS2F18LS432 DPS2T18LS332 DPS2T18LS432 DPA2G18LS332 Deepcel Plus 3" Precision contoured pre-anodized aluminum parabolic louver Philips Lightolier 30˚ Ordering information Air closure strips: ACS4 (factory installed). ACS4 CSP (field installed). 4.118 60˚ Input watts (120V) 85.8W Luminaire eff. (LER) 68.6 UNV H3 Voltage Ballast 120 = 120V See page 4.118 277 = 277V UNV= 120-277V ACS4 Options See page 4.118 and page 4.130 (Elec. T8 ballast only) For complete specification information visit www.lightolier.com Specification – Linear recessed and surface lighting Deepcel Plus 2' x 4' 3" Parabolic louver recessed air return/static luminaires Philips Lightolier Deepcel Plus is the industry standard 3" parabolic louver troffer with features that offer value above the industry standard. DPA2G12LS232UNVHI Candlepower Curve Reference data Features Efficiency 80.0% Spacing ratio 1.6 5" (127mm) Electronic ballast • 5" deep body. 60˚ 650 Input watts (120V) 61.6W Luminaire Eff. (LER) 64.4 24" (610mm) • 80% efficient, 2 lamp 12 cell. • Clean contoured interior. • Eyeleted heat removal vents in fixture ends. 1300 • One piece housing. • Black exterior for cooler ballast operating temperature. 1950 30˚ • Hemmed over side rails for safe handling. • Fixture ends turned-in for safe handling. 8 Cell • Built-in earthquake clips. 12 Cell 12 Cell • Pre-anodized aluminum parabolic louver. Ordering information Type 9 Cell 18 Cell Size Cells Lamp qty –type Air handling 2' x 4' 12 2-T8 4-T8 Static 2' x 4' 12 2-T8 4-T8 12 Cell 16 Cell 18 Cell Deepcel Plus 3" Precision contoured pre-anodized aluminum parabolic louver Flanged for dry or plaster Slot-T or Concealed T DPA2G12LS232 DPA2G12LS432 DPA2F12LS232 DPA2F12LS432 DPA2T12LS232 DPA2T12LS232 • 18 gauge steel hinges. DPS2G12LS232 DPS2G12LS432 DPS2F12LS232 DPS2F12LS432 DPS2T12LS232 DPS2T12LS432 • Snap-in ballast cover. 24 Cell DPA2G12LS232 Example • Vertical grain louver eliminates reflected lamp images on cross baffle. Exposed T-Grid UNV 32 Cell HI • Spring-loaded rooster head latches. • 1.6 spacing to mounting height ratio. • Louver frame with integral positive light stop. • Louver has protective film dust guard. ACS4 Voltage Ballast 120 = 120V See page 4.119 277 = 277V UNV= 120-277V Options & accessories Options See page 4.119 and page 4.130 page 4.130 Louver finish: Low iridescence semi-specular is standard. Consult factory for other finishes. Ballast: Specify voltage (120, 277 or UNV) and type and add as suffix, e.g. UNVHI. (Elec. T8 ballast only) Ballast type <10THD <20THD DPA2G32LS432UNVH4 Candlepower Curve Reference data 5" (127mm) Efficiency 64.1% Spacing ratio 1.4 Electronic ballast 24" (610mm) 1100 60˚ Input watts (120V) 110.9W Luminaire Eff. (LER) 56.7 Electronic T8 HI*, P2** SO* 1 - 4 Lamp elec. T8 H4*, P4** O4* LOL T8 Dimming – PS * Instant start. ** Program start. Consult factory for other wattages. 2200 Drywall kit: Conversion kit for 2' x 4' unit: FK92X4. 3300 24 Cell Ordering information Cells Lamp qty –type 2' x 4' 32 2' x 4' 32 Size Air handling Static Electrical/wiring options: For special wiring, fusing, electronic dimming ballasts, consult factory. Plaster frame: For type F troffers, order plaster frames separately. Catalog no. PF24 for 2' x 4' troffer. 32 Cell Type 30˚ Exposed T-Grid Flanged for dry or plaster Slot-T or Concealed T 4-T8 DPA2G32LS432 DPA2F32LS432 DPAT32LS432 4-T8 DPS2G32LS432 DPS2F32LS432 DPS2T32LS432 Continuous row installation: For “F” type fixtures, half-width flanges are required between fixtures. Catalog no. 2FCTRIM (each joint). Air closure strips: ACS4 (factory installed). ACS4 CSP (field installed). Chicago Plenum: Suffix: C. For products that meet Chicago Plenum requirements. NYC code: Change DP to DY. Example DPA2G32LS432 Deepcel Plus 3" Precision contoured pre-anodized aluminum parabolic louver UNV H4 Voltage Ballast 120 = 120V See page 4.119 277 = 277V UNV= 120-277V ACS4 Options See page 4.119 and page 4.130 (Elec. T8 ballast only) Comprehensive lighting catalog 7th Edition 4.119 Linear recessed and surface lighting – Specification Deepcel Plus 2' x 2' 3" Parabolic louver recessed air handling/static luminaires Deepcel Plus 2' x 2' parabolic troffers feature all of the design benefits of the 2' x 4' product. Available with T8 and Biax type lamps in 9, 12 or 16 cell configurations. For general office lighting Deepcel Plus 2' x 2' is the preferred choice. DPA2G9LS26UUNVHI Features 8 Cell 8 Cell • 5" deep body, clean contoured interior. 12 Cell 12 Cell • 66.2% efficient, 2 lamp 9 cell U6 T8. 12 Cell 12 Cell 5" (127mm) Candlepower Curve Reference data Efficiency 66.2% Spacing ratio 1.2 Electronic ballast • 63.4% efficient, 3 lamp 9 cell T8 1.6. 24" (610mm) • Eyeleted heat removal vents in fixture ends. • One piece housing. 1100 • Black exterior for cooler ballast operating temperature. • Hemmed over side rails for safe handling. 9 Cell 9 Cell • Fixtures ends turned-in for safe handling. 60˚ 550 Input watts (120V) 57.2W Luminaire eff. (LER) 53.4 12 Cell 12 Cell 16 Cell 16 Cell 18 Cell 18 Cell 24 Cell 24 Cell 32 Cell 32 Cell 1650 30˚ • Built-in earthquake clips. • Pre-anodized aluminum parabolic louver. • Vertical grain louver eliminates reflected lamp images on cross baffle. • Spring-loaded rooster head latches. • 18 gauge steel hinges. • Louver frame with integral positive light stop. • Louver has protective film dust guard. • Available for U-shape Octron Curvalume or Biax lamp types. Options & accessories Ordering information HI*, P2** SO* 1 - 3 Lamp elec. T8 H3*, P3** O3* LOL T8 Dimming – 9 12 2' x 2' 9 12 Air handling Static Exposed T-Grid Flanged for dry or plaster Slot-T or Concealed T 2-T8U6 DPA2G9LS26U DPA2G12LS26U DPA2F9LS26U DPA2F12LS26U DPA2T9LS26U DPA2T12LS26U 2-T8U6 DPS2G9LS26U DPS2G12LS26U DPS2F9LS26U DPS2F12LS26U DPS2G9LS26U DPS2T12LS26U DPA2G9LS26U Deepcel Plus 3" Precision contoured pre-anodized aluminum parabolic louver Ballast: Specify voltage (120, 277 or UNV) and type and add as suffix, e.g. UNVHI. Electronic T8 2' x 2' Size Louver finish: Low iridescence semi-specular is standard. Consult factory for other finishes. Ballast type <10THD <20THD Cells Type Example page 4.130 For 17W T8 substitute 6U with 17 in Catalog number. Lamp qty –type UNV 12 Cell 12 Cell PS ACS2 Options See page 4.120 and page 4.130 (Elec. T8 or TT5 ballast only) DPA2G9LP32UUNVH3 8 Cell 8 Cell HI Voltage Ballast 120 = 120V See page 4.120 277 = 277V UNV= 120-277V 12 Cell 12 Cell 5" (127mm) Candlepower Curve Reference data Efficiency 63.4% Spacing ratio 1.4 Electronic ballast * Instant start. 24" (610mm) ** Program start. 800 60˚ Input watts (120V) 57.2W Luminaire eff. (LER) 56.2 Consult factory for other wattages. 1600 Drywall kit: Conversion kit for 2' x 2' unit: FK92X2. Electrical/wiring options: For special wiring, fusing, electronic dimming ballasts, consult factory. Plaster frame: For type F troffers, order plaster frames separately. Catalog no. PF22 for 2' x 2' troffer. Continuous row installation: For “F” type fixtures, half-width flanges are required between fixtures. Catalog no. 2FCTRIM (each joint). 9 Cell 9 Cell 12 Cell 12 Cell 16 Cell 16 Cell Ordering information Type Size Cells Air closure strips: ACS2 (factory installed). ACS2 CSP (field installed). Air handling 2' x 2' 9 12 Chicago Plenum: Suffix: C. For products that meet Chicago Plenum requirements. Static 2' x 2' 9 12 18 Cell 18 Cell 24 Cell 24 Cell 32 Cell 32 Cell 2400 30˚ For 17W T8 substitute 2U with 17 in Catalog number. Lamp qty –type Exposed T-Grid Flanged for dry or plaster Slot-T or Concealed T 3-T8U1.6 DPA2G9LP32U DPA2G12LP32U DPA2F9LP32U DPA2F12LP32U DPA2T9LP32U DPA2T12LP32U 3-T8U1.6 DPS2G9LP32U DPS2G12LP32U DPS2F9LP32U DPS2F12LP32U DPS2T9LP32U DPS2T12LP32U NYC code: Change DP to DY. Example DPA2G9LP32U Deepcel Plus 3" Precision contoured pre-anodized aluminum parabolic louver 4.120 Philips Lightolier UNV H3 Voltage Ballast 120 = 120V See page 4.120 277 = 277V UNV= 120-277V ACS2 Options See page 4.120 and page 4.130 (Elec. T8 or TT5 ballast only) For complete specification information visit www.lightolier.com Specification – Linear recessed and surface lighting Deepcel Plus 2' x 2' 3" Parabolic louver recessed air handling/static luminaires Deepcel Plus 2' x 2' parabolic troffers feature all of the design benefits of the 2' x 4' product. Available with T8 and Biax type lamps in 9, 12 or 16 cell configurations. For general office lighting Deepcel Plus 2' x 2' is the preferred choice. DPA2G16LS26UUNVHI 8 Cell Candlepower Curve Reference data 12 Cell 12 Cell Efficiency 61.6% Spacing ratio 1.3 5" (127mm) Electronic ballast • 5" deep body, clean contoured interior. • 61.6% efficient, 2 lamp 9 cell U6 T8. 60˚ 550 Input watts (120V) 51.5W Luminaire eff. (LER) 49.4 24" (610mm) Features • 72.0% efficient, 3 lamp 9 cell TT5. • Eyeleted heat removal vents in fixture ends. • One piece housing. 1100 • Black exterior for cooler ballast operating temperature. • Hemmed over side rails for safe handling. 9 Cell 12 Cell 16 Cell 18 Cell 24 Cell 1650 32 Cell 30˚ • Fixtures ends turned-in for safe handling. • Built-in earthquake clips. Ordering information For 17W T8 substitute 6U with 17 in Catalog number. Cells Lamp qty –type 2' x 2' 16 2' x 2' 16 Type Size Air handling Static • Pre-anodized aluminum parabolic louver. • Vertical grain louver eliminates reflected lamp images on cross baffle. Exposed T-Grid Flanged for dry or plaster Slot-T or Concealed T 2-T8U6 DPA2G16LS26U DPA2G16LS26U DPA2T16LS26U • 18 gauge steel hinges. 2-T8U6 DPS2G16LS26U DPS2F16LS26U DPS2T16LS26U • Louver frame with integral positive light stop. • Spring-loaded rooster head latches. • Louver has protective film dust guard. DPA2G16LS26U Example UNV Deepcel Plus 3" Precision contoured pre-anodized aluminum parabolic louver HI Voltage Ballast 120 = 120V See page 4.121 277 = 277V UNV= 120-277V • Available for U-shape Octron Curvalume or Biax type. ACS2 Options & accessories Options See page 4.121 and page 4.130 page 4.130 Louver finish: Low iridescence semi-specular is standard. Consult factory for other finishes. Ballast: Specify voltage (120, 277 or UNV) and type and add as suffix, e.g. UNVHI. (Elec. T8 or TT5 ballast only) Ballast type <10THD <20THD DPA2G9LP3FT120SB & DPA2G12LP3FT120SB 8 Cell 8 Cell 12 Cell 12 Cell 12 Cell 12 Cell 5" (127mm) 24" (610mm) Candlepower Curve Reference data Efficiency 72.0% Spacing ratio 1.5 SO* I3* X3* IB*, PR** SB* LOL T8 Dimming – PS LOL TT5 Dimming – PB 1 - 3 Lamp elec. TT5 40W Electronic TT5 40W 1050 60˚ Electronic ballast Input watts (120V) 100.0W Luminaire eff. (LER) 59.9 HI*, P2** Electronic T8 * Instant start. ** Program start. 2100 Consult factory for other wattages. 9 Cell 9 Cell 12 Cell 12 Cell 16 Cell 16 Cell 18 Cell 18 Cell 24 Cell 24 Cell 32 Cell 32 Cell 3150 Size Cells Air handling 2' x 2' 9 12 Static 2' x 2' 9 12 Exposed T-Grid Flanged for dry or plaster Slot-T or Concealed T Plaster frame: For type F troffers, order plaster frames separately. Catalog no. PF22 for 2' x 2' troffer. 3-TT5 DPA2G9LP3FT DPA2G12LP3FT DPA2F9LP3FT DPA2F12LP3FT DPA2T9LP3FT DPA2T12LP3FT 3-TT5 DPS2G9LP3FT DPS2G12LP3FT DPS2F9LP3FT DPS2G12LP3FT DPS2T9LP3FT DPS2T12LP3FT Continuous row installation: For “F” type fixtures, half-width flanges are required between fixtures. Catalog no. 2FCTRIM (each joint). Lamp qty –type DPA2G9LP3FT Example Deepcel Plus 3" Precision contoured pre-anodized aluminum parabolic louver Drywall kit: Conversion kit for 2' x 2' unit: FK92X2. Electrical/wiring options: For special wiring, fusing, electronic dimming ballasts, consult factory. Ordering information Type 30˚ 120 X3 Voltage Ballast 120 = 120V See page 4.121 277 = 277V UNV= 120-277V ACS2 Options See page 4.121 and page 4.130 Air closure strips: ACS2 (factory installed). ACS2 CSP (field installed). Chicago Plenum: Suffix: C. For products that meet Chicago Plenum requirements. NYC code: Change DP to DY. (Elec. T8 or TT5 ballast only) Comprehensive lighting catalog 7th Edition 4.121 Linear recessed and surface lighting – Professional Prismalyte Plus 2' x 4' Premium specification lensed recessed air handling luminaires Prismalyte Plus luminaires are top of the line air handling lensed fluorescent luminaires with floating door appearance, regressed, aluminum doors and black painted housing for optimum lamp and ballast operations. Door frames are interchangeable with Deepcel Plus 2' x 4' louvers. PRA2GRFVA432UNVH4 Features • 5" deep body (2' x 4'). • Black housing exterior for cooler ballast operating temperature. Electronic ballast 24" (610mm) • Hemmed over side rails for safety. • Fixture ends turned in for safe handling. 1250 60˚ Input watts (120V) 109.5W Luminaire eff. (LER) 68.7 5" (127mm) • Door jamb finished black on four sides for positive light stop. 2500 24" (610mm) • True mitered corner aluminum lens frame. 3750 5" (127mm) • Interchangeable with Deepcel and Parabaffle louvers. • Spring loaded rooster head latches. Options & accessories Efficiency 76.7% Spacing ratio 1.3 5" (127mm) • Built-in earthquake clips on 2' x 4'. Candlepower Curve Reference data 30˚ 24" (610mm) page 4.130 Special lenses: VA lens pattern 12 prismatic virgin acrylic is standard. For other available lenses, see options and accessories page. Ballast: Specify voltage (120, 277 or UNV) and type and add as suffix, e.g. UNVHI. Ordering information HI*, P2** SO* 1 - 3 Lamp Elec. T8 H3*, P3** O3* 1 - 4 Lamp Elec. T8 H4*, P4** O4* * Instant start. ** Program start. Consult factory for other wattages. Drywall kit: C onversion kit for 2' x 4' unit: FK92X4. Electrical/wiring options: For special wiring, fusing, electronic dimming ballasts, consult factory. Flanged for dry or plaster Size Air handling 2' x 4' 2-T8 3-T8 4-T8 PRA2GRFVA232 PRA2FRFVA232 PRA2GRFVA332 PRA2GRFVA332 PRA2FRFVA432 PRA2FRFVA432 Static 2' x 4' 2-T8 3-T8 4-T8 PRS2GRFVA232 PRS2FRFVA332 PRS2GRFVA432 Ballast type <10THD <20THD Electronic T8 Lamps qty –type Type Example PRA2GRFVA432 Prismalyte Plus Floating lens frame recessed fluorescent troffer Exposed T-Grid UNV PRS2FRFVA232 PRS2FRFVA332 PRS2GRFVA432 H4 Voltage Ballast 120 = 120V See page 4.122 277 = 277V UNV= 120-277V C Options See page 4.122 and page 4.130 (Elec. T8 or TT5 Ballast only) Plaster frame: For type F troffers, order plaster frames separately. Catalog no. PF24 for 2' x 4' troffer. Air closure strips: ACS4 (factory installed). ACS4 CSP (field installed). Chicago Plenum: Suffix: C. For products that meet Chicago Plenum requirements. For NYC code consult factory 4.122 Philips Lightolier For complete specification information visit www.lightolier.com Professional – Linear recessed and surface lighting Prismalyte Plus 2' x 2' & 1' x 4' Premium specification lensed recessed air handling luminaires Prismalyte Plus luminaires are top of the line air handling lensed fluorescent luminaires with floating door appearance, regressed, aluminum doors and black painted housing for optimum lamp and ballast operations. Door frames are interchangeable with Deepcel Plus 2' x 2' louvers. PRA2GRFVA26UUNVHI & PRA2GRFVA32UUNVH3 5" (127mm) PRA26U 24" (610mm) Candlepower Curve Reference data Efficiency 71.6% Spacing ratio 1.2 PRA32U 24" (610mm) 600 1800 800 Exposed T-Grid Air handling 2' x 2' 2-T8U6 PRA2GRFVA26U PRA2FRFVA26U 3-T8U1.6/ PRA2GRFVA32U PRA2FRFVA32U 3-TT5 PRA2GRFVA3FT PRA2FRFVA3FT 2' x 2' 2-T8U6 PRS2GRFVA26U PRS2FRFVA26U 3-T8U1.6/ PRS2GRFVA32U PRS2FRFVA32U 3-TT5 PRS2GRFVA3FT PRS2FRFVA3FT PRA2GRFVA26U Prismalyte Plus Floating lens frame recessed fluorescent troffer UNV HI Voltage Ballast 120 = 120V See page 4.123 277 = 277V UNV= 120-277V 2400 Ballast type <10THD <20THD C 1-T8 2-T8 Example PRA1GRFVA232 Prismalyte Plus Floating lens frame recessed fluorescent troffer HI*, P2** SO* 1 - 3 Lamp Elec. T8 H3*, P3** O3* 1 - 3 Lamp Elec. TT5 40W IB*, PR** X3* IB* SB * Instant start. ** Program start. Consult factory for other wattages. Candlepower Curve Efficiency 65.4% Spacing ratio 1.3 600 Ordering information 1' x 4' Electronic T8 Electronic TT5 40W Options See page 4.123 and page 4.130 60˚ Exposed T-Grid Flanged for dry or plaster PRA1GRFVA132 PRA1GRFVA232 PRA1FRFVA132 PRA1FRFVA232 PRS1GRFVA132 PRS1GRFVA232 PRS1FRFVA132 PRS1FRFVA232 UNV HI Voltage Ballast 120 = 120V See page 4.123 277 = 277V UNV= 120-277V 1800 Electrical/wiring options: For special wiring, fusing, electronic dimming ballasts, consult factory. Plaster frame: For type F troffers, order plaster frames separately. Catalog no. PF22 for 2' x 2' troffer. Catalog no. PF14 for 1' x 4' troffer. Air closure strips: ACS2 (factory installed). ACS2 CSP (field installed). 1200 Static page 4.130 30˚ Input watts (120V) 56.6W Luminaire eff. (LER) 58.0 1' x 4' Options & accessories Ballast: Specify voltage (120, 277 or UNV) and type and add as suffix, e.g. UNVHI. Reference data 12" (305mm) Air handling • Interchangeable with Deepcel and Parabaffle louvers. Special lenses: VA lens pattern 12 prismatic virgin acrylic is standard. For other available lenses, see options and accessories page. 1600 Electronic ballast 1-T8 2-T8 • True mitered corner aluminum lens frame. Drywall kit: C onversion kit for 2' x 2' unit: FK92X2. Conversion kit for 1' x 4' unit: FK91X4. 4" (101mm) Size 60˚ (Elec. T8 or TT5 Ballast only) PRA1GFVA232UNVHI Lamps qty –type • Door jamb finished black on four sides for positive light stop. • Spring loaded rooster head latches. Flanged for dry or plaster Size Type 30˚ Candlepower Curve Type Example • Fixture ends turned in for safe handling. Reference data Input watts (120V) 76.0W Luminaire eff. (LER) 63.4 Lamps qty –type • Black housing exterior for cooler ballast operating temperature. • Hemmed over side rails for safety. 1200 Electronic ballast Static 60˚ • Built-in earthquake clips on 2' x 2'. Input watts (120V) 60.0W Luminaire eff. (LER) 58.0 Efficiency 67.0% Spacing ratio 1.3 Ordering information • 5" deep body (2' x 2'). • 4" deep (1' x 4' G Type). Electronic ballast 5" (127mm) Features Chicago Plenum: Suffix: C. For products that meet Chicago Plenum requirements. 30˚ For NYC code consult factory C Options See page 4.123 and page 4.130 (Elec. T8 or TT5 Ballast only) Comprehensive lighting catalog 7th Edition 4.123 Linear recessed and surface lighting – Specification Specplus 2' x 4' Specification grade lensed recessed static luminaires Specplus has all the features you look for in a TRUE specification grade lens troffer. Our 5" depth reverses the industry trend of making fixtures shallower thus putting the lamps closer to the lens. And there is more. SPS2GFSVA432UNVH4 Features Reference data • 5" deep body (2' x 4'). Efficiency 81.2% Spacing ratio 1.3 5" (127mm) • 3 1/16" lamp to lens for better lamp obscuration (2' x 4'). Candlepower Curve Electronic ballast • 81.2% efficient (4 light). 24" (610mm) • Clean contoured interior, no holes. 1250 • Hemmed over side rails for maximum safety. 2500 5" (127mm) • Fixture ends turned-in for safe handling. • Built-in earthquake clips (2' x 4'). • Slimline Door frame with 475 and 1000 square inch lens openings (2' x 4'). 60˚ Input watts (120V) 108.7W Luminaire Eff. (LER) 73.2 3750 24" (610mm) • Door jamb finished black on four sides for positive light stop. 30˚ 5" (127mm) • True Mitered corner steel lens frame. 24" (610mm) • Spring loaded rooster head latches. • 18 gauge steel hinges. • Flat and regressed aluminum doors available. Ordering information • Construction to meet Chicago Plenum requirements is available. Options & accessories Type Size Static 2' x 4' page 4.130 Special lenses: VA lens pattern 12 prismatic virgin acrylic is standard. For other available lenses, see options and accessories page. Ballast: Specify voltage (120, 277 or UNV) and type and add as suffix, e.g. UNVHI. Example HI*, P2** SO* 1 - 3 Lamp Elec. T8 H3*, P3** O3* 1 - 4 Lamp Elec. T8 H4*, P4** O4* * Instant start. 2-T8 3-T8 4-T8 Exposed T-Grid Flanged for dry or plaster SPS2GFSVA232 SPS2GFSVA332 SPS2GFSVA432 SPS2FFSVA232 SPS2FFSVA332 SPS2FFSVA432 SPS2GFSVA432 Specplus Lens Frame Recessed Fluorescent Troffer Ballast type <10THD <20THD Electronic T8 Lamps qty –type Sky lens ** Program start. Drywall kit: C onversion kit for 2' x 4' unit: FK92X4. Electrical/wiring options: For special wiring, fusing, electronic dimming ballasts, consult factory. Plaster frame: For type F troffers, order plaster frames separately. Catalog no. PF24 for 2' x 4' troffer. Door frames: SPS2GFS (Flat steel door). SPS2GFA (Flat aluminum door). SPS2GRA (Regressed aluminum door). Chicago Plenum: Suffix: C. For products that meet Chicago Plenum requirements. 4.124 Philips Lightolier H4 Voltage Ballast 120 = 120V See page 4.124 277 = 277V UNV= 120-277V A Options See page 4.124 and page 4.130 (Elec. T8 or TT5 Ballast only) The Sky lens offers an aesthetically pleasing lens option for any environment giving you the ability to customize your space. The Sky lens exudes a soothing alternative to conventional lenses when used in areas such as health care waiting or examination rooms, assisted living common areas or child care faculties. These options are available on the Philips Lightolier SpecPlus Recessed Fluorescent 2' x 2' and 2' x 4' models. To order the Sky Lens simply insert your choice of Sky lenses, S1 or S2, into the standard SpecPlus (SPS) Catalog number. Continuous row installation: For “F” type fixtures, half-width flanges are required between fixtures. Catalog no. 2FCTRIM (each joint). Fusing: Suffix: A (Internal fast-blow fusing). Suffix: C (Internal slow-blow fusing). UNV Sky lens 2' x 4' S1 Sky lens 2' x 2' S1 Sky lens 2' x 4' S2 Sky lens 2' x 2' S2 Example Standard: SPS2GFS VA 232UNVHI Sky Lens: SPS2GFS S1 232UNVHI For complete specification information visit www.lightolier.com Specification – Linear recessed and surface lighting Specplus 2' x 2' & 1' x 4' Specification grade lensed recessed static luminaires Specplus has all the features you look for in a TRUE specification grade lens troffer. Our 5" depth reverses the industry trend of making fixtures shallower thus putting the lamps closer to the lens. And there is more. SPS2GFSVA26UUNVHI & SPS2GFSVA32UUNVH3 Candlepower Curve Reference data 5" 5" (127mm) (127mm) Efficiency 71.6% Spacing ratio 1.3 Electronic ballast 24" 24" (610mm) (610mm) • 5" deep body (2' x 2'). • 3 1/16" lamp to lens for better lamp obscuration (2' x 2'). 600 24" (610mm) Static 2' x 2' Lamps qty –type 2-T8U6 3-TT5 3-T8U1.6/ 3-T8F17 SPS2GFSVA26U Example • Fixture ends turned-in for safe handling. • Built-in earthquake clips (2' x 2'). 1800 30˚ Candlepower Curve Input watts (120V) 76.2W Luminaire Eff. (LER) 64.1 Ordering information Size • Hemmed over side rails for maximum safety. 1200 Reference data Efficiency 67.9% Spacing ratio 1.3 Prismalyte Plus Floating Lens Frame Recessed Fluorescent Troffer Exposed T-Grid Flanged for dry or plaster SPS2GFSVA26U SPS2GFSVA3FT SPS2GFSVA32U SPS2GFSVA317 SPS2FFSVA26U SPS2FFSVA3FT SPS2FFSVA32U SPS2FFSVA317 UNV HI Voltage Ballast 120 = 120V See page 4.125 277 = 277V UNV= 120-277V • 71.6% efficient (2-6U T8). • Clean contoured interior, no holes. Electronic ballast Type 60˚ Input watts (120V) 56.3W Luminaire Eff. (LER) 63.1 5" (127mm) Features 800 60˚ • Slimline Door frame with 475 and 1000 square inch lens openings (2' x 2'). • Door jamb finished black on four sides for positive light stop. • True Mitered corner steel lens frame. • Spring loaded rooster head latches. • 18 gauge steel hinges. • Flat and regressed aluminum doors available. 1600 • Construction to meet Chicago Plenum requirements is available. 2400 30˚ A Options & accessories page 4.130 Special lenses: VA lens pattern 12 prismatic virgin acrylic is standard. For other available lenses, see options and accessories page. Options See page 4.125 and page 4.130 Ballast: Specify voltage (120, 277 or UNV) and type and add as suffix, e.g. UNVHI. (Elec. T8 or TT5 Ballast only) Ballast type <10THD <20THD Electronic T8 HI*, P2** SO* 1 - 3 Lamp Elec. T8 H3*, P3** O3* I3* X3* 1 - 3 Lamp Elec. TT5 40W SPS1GFSVA232UNVHI Electronic TT5 40W Candlepower Curve Reference data Efficiency 69.0% Spacing ratio 1.3 4" (101mm) 12" (305mm) Electronic ballast 800 60˚ Type Size 1200 Static Example 1' x 4' Lamps qty –type 1-T8 2-T8 SPS1GFSVA232 Specplus Lens Frame Recessed Fluorescent Troffer Exposed T-Grid Flanged for dry or plaster SPS1GFSVA132 SPS1GFSVA232 SPS1FFSVA132 SPS1FFSVA232 UNV HI Voltage Ballast 120 = 120V See page 4.125 277 = 277V UNV= 120-277V (Elec. T8 or TT5 Ballast only) * Instant start. ** Program start. Drywall kit: C onversion kit for 2' x 2' unit: FK92X2. Conversion kit for 1' x 4' unit: FK91X4. Electrical/wiring options: For special wiring, fusing, electronic dimming ballasts, consult factory. Input watts (120V) 55.8W Luminaire Eff. (LER) 62.0 Ordering information IB*, PR** SB* 1800 A Options See page 4.125 and page 4.130 Plaster frame: For type F troffers, order plaster frames separately. Catalog no. PF22 for 2' x 2' troffer. Catalog no. PF14 for 1' x 4' troffer. 30˚ Continuous row installation: For “F” type fixtures, half-width flanges are required between fixtures. Catalog no. 2FCTRIM (each joint - 2' x 2'). Catalog no. 1FCTRIM (each joint - 1' x 4'). Door frames: SPS2GFS (Flat steel door). SPS2GFA (Flat aluminum door). SPS2GRA (Regressed aluminum door). Fusing: Suffix: A (Internal fast-blow fusing). Suffix: C (Internal slow-blow fusing). Chicago Plenum: Suffix: C. For products that meet Chicago Plenum requirements. Comprehensive lighting catalog 7th Edition 4.125 Linear recessed and surface lighting – Standard XP series 2' x 4' High perform lensed recessed static luminaires Philips Lightolier’s XP troffer offers high efficiencies and unique features at an affordable price. XP2GVA432UNVH4 • Efficiency: 83.0% (4 lamp), 85.0% (3 lamp), 87.0% (2 lamp). Ordering information • Shallow 3" deep housing. Type Size XP Static 2' x 4' • Ribbed housing for strength and stability. • Ends of housing formed inward for safe handling. • Built-in earthquake clips. • Hemmed-over side rails for safe handling. Example • Ends have screw dimples for installation to T-bar (no fixture or ceiling distortion). • Edges of steel or regressed Door frame hemmedover for safe handling. 60˚ 1200 Input watts (120V) 112.0W Luminaire Eff. (LER) FL - 74.3 2400 Lamps qty –type 4-T8 Exposed T-Grid Flanged for dry or plaster XP2GVA432 XP2FVA432 XP2GVA432 UNV XP Flat Steel Lens Frame Recessed Fluorescent Troffer • Flat steel or regressed aluminum lens frame with mitered corners. Efficiency 83.0% Spacing ratio 1.4 Electronic ballast 24" (610mm) Features Candlepower Curve Reference data 3" (76mm) 3600 H4 Voltage Ballast 120 = 120V See page 4.126 277 = 277V UNV= 120-277V 30˚ A Options See page 4.126 and page 4.130 (Elec. T8 Ballast only) • No light leak. • Internal “T” hinges-easy installation and maintenance. • Rooster head spring latches. XP2GVA332UNVH3 Options & accessories 3" (76mm) page 4.130 Special lenses: VA lens pattern 12 prismatic virgin acrylic is standard. For other available lenses, see options and accessories page. 24" (610mm) 24" (610mm) Type Size Ballast type <10THD <20THD XP Static 2' x 4' Electronic T8 HI*, P2** SO* 1 - 3 Lamp Elec. T8 H3*, P3** O3* 1 - 4 Lamp Elec. T8 H4*, P4** O4* Example ** Program start. Drywall kit: Catalog no. FK92X4 with fixtures for drywall or plaster ceilings. Electrical/wiring options: For special wiring, fusing, electronic dimming ballasts, consult factory. 1900 Lamps qty –type 3-T8 Exposed T-Grid Flanged for dry or plaster XP2GVA332 XP2FVA332 XP2GVA332 UNV 24" (610mm) 24" (610mm) 2' x 4' Example Philips Lightolier 650 60˚ Input watts (120V) 58.0W Luminaire Eff. (LER) FL - 74.3 1300 Lamps qty –type 2-T8 Exposed T-Grid Flanged for dry or plaster XP2GVA232 XP2FVA232 XP2GVA232 XP Flat Steel Lens Frame Recessed Fluorescent Troffer 4.126 Candlepower Curve Efficiency 87.0% Spacing ratio 1.4 Electronic ballast Ordering information XP Static A (Elec. T8 Ballast only) 3" (76mm) Size 30˚ Options See page 4.126 and page 4.130 Reference data Plaster frame: For type F troffers, order plaster frames separately. Catalog no. PF24 for 2' x 4' troffer. Type 2850 H3 Voltage Ballast 120 = 120V See page 4.126 277 = 277V UNV= 120-277V XP2GVA232UNVHI Fusing: Suffix: A (Internal fast-blow fusing). Suffix: C (Internal slow-blow fusing). 60˚ 950 Input watts (120V) 85.0W Luminaire Eff. (LER) FL - 75.2 XP Flat Steel Lens Frame Recessed Fluorescent Troffer * Instant start. Efficiency 85.0% Spacing ratio 1.4 Electronic ballast Ordering information Ballast: Specify voltage (120, 277 or UNV) and type and add as suffix, e.g. UNVHI. Candlepower Curve Reference data • Meets code 30 requirements in New England. UNV HI Voltage Ballast 120 = 120V See page 4.126 277 = 277V UNV= 120-277V 1950 30˚ A Options See page 4.126 and page 4.130 (Elec. T8 Ballast only) For complete specification information visit www.lightolier.com Standard – Linear recessed and surface lighting XP / XA series 2' x 2' & 1' x 4' High perform lensed recessed static luminaires Philips Lightolier’s high performance XP/XA series of lensed troffers offers unique features that outperform and extend more value for money than any other comparable fluorescent troffer. XP2GVA26UUNVHI Reference data (SO) 3" (76mm) XP Static 2' x 2' XA Static 2' x 2' Example 60˚ 600 1200 Lamps qty –type • Built-in earthquake clips. Reference data (SB) Exposed T-Grid 2-TT5 2-T8U6 XP2GVA2FT XP2GVA26U 2-TT5 2-T8U6 XA2GVA2FT XA2GVA26U XP2GVA26U Efficiency 84.1% Spacing ratio 1.3 1800 30˚ • Flush steel full-sized Door frame with mitered corner detailing. • Angle regressed extruded aluminum door option. • End cap has single form configuration and formed edges for easy lamping and safety. Electronic ballast Input watts (120V) 58.0W Luminaire Eff. (LER) 74.3 • Door frame overlaps end cap for positive light stop. • UL-Listed twin knock-out access plate for easy closeddoor wiring. UNV XP Flat Steel Lens Frame Recessed Fluorescent Troffer XA Regressed Aluminum Lens Frame Recessed Fluorescent Troffer • 4" deep (1' x 4'). 3 1/2" deep (2' x 2'). • Fixture side rails have rolled-over edges for maximum safety. Input watts (120V) 55.3W Luminaire Eff. (LER) 62.3 Ordering information Size Features Electronic ballast 24" (610mm) Type Candlepower Curve Efficiency 71.7% Spacing ratio 1.3 HI Voltage Ballast 120 = 120V See page 4.127 277 = 277V UNV= 120-277V A • Fits new narrow slot grid ceiling systems. Options & accessories Options See page 4.127 and page 4.130 page 4.130 Special lenses: VA lens pattern 12 prismatic virgin acrylic is standard. For other available lenses, see options and accessories page. (Elec. T8 Ballast only) Ballast: Specify voltage (120, 277 or UNV) and type and add as suffix, e.g. UNVHI. Ballast type <10THD <20THD XP1GVA232UNVHI Efficiency 69.0% Spacing ratio 1.3 4" (101mm) Electronic ballast 12" (305mm) 600 60˚ Input watts (120V) 55.8W Luminaire Eff. (LER) 62.0 Type Size Lamps qty –type Exposed T-Grid Flanged for dry or plaster XP Static 1' x 4' 2-T8/T12 XP1GVA232 XP1FVA232 XA Static 1' x 4' 2-T8/T12 XA1GVA232 XA1FVA232 XP1GVA232 XP Flat Steel Lens Frame Recessed Fluorescent Troffer XA Regressed Aluminum Lens Frame Recessed Fluorescent Troffer UNV HI Voltage Ballast 120 = 120V See page 4.127 277 = 277V UNV= 120-277V 1800 Electronic T8 HI*, P2** SO* 1 - 3 Lamp Elec. T8 H3*, P3** O3* Electronic TT5 40W IB*, PR** SB* * Instant start. ** Program start. Drywall kit: Catalog no. FK91X4 or FK92X2 with fixtures for drywall or plaster ceilings. 1200 Ordering information Example Candlepower Curve Reference data 30˚ Electrical/wiring options: For special wiring, fusing, electronic dimming ballasts, consult factory. Seismic Hold-Down Clip: Suffix: 2HD. For 1' x 4', type G, factory installed. Plaster frame: For type F troffers, order plaster frames separately. Catalog no. PF14 for 1' x 4' troffer. Fusing: Suffix: A (Internal fast-blow fusing). Suffix: C (Internal slow-blow fusing). A Options See page 4.127 and page 4.130 Chicago Plenum: Suffix: C. For products that meet Chicago Plenum requirements. For NYC code consult factory (Elec. T8 Ballast only) Comprehensive lighting catalog 7th Edition 4.127 Linear recessed and surface lighting – Standard FRX 2' x 2' Recessed luminaires The FRX Series offers an architecturally decorative lighting element that will enhance your boardrooms, entrances or executive offices. The 2' x 2' frost white acrylic lens with softly rounded edges provides a luminescent glow of light. Features • Creative side-by-side installations can generate rows, squares, rectangles, "+" shapes, "T" shapes and other geometric figures. • Illuminates both horizontal and vertical surfaces. • Lens opens from either side. • Lens utilizes spring loaded latches/hinge. • 5" deep body. • Fixture fits a Standard 15/16" or 9/16" T-grid ceiling. Options & accessories page 4.130 Ballast type <10THD <20THD 2 Lamp Elec. T5HO 14/24W PG – 2 Lamp Elec. TT5 25/40W IB* SB* 2 Lamp Elec. TT5 40W PR** – 2 Lamp Elec. TT5 50W – BP 2 Lamp Elec. TT5 55W BF – LOL Dimming TT5 – PB 1-2 Lamp Elec. T8 HI SO LOL T8 Dimming – PS * Instant start. ** Program start. 24" (610mm) 5" (127mm) 1316" (21mm) 23-7/8" (606mm) Square Lens Ordering information Cat. no. Fixture efficiency Lamps type Lamp watts FRS2GFW2FTUNVIB FRS2GFW26UUNVHI FRS2GFW224UNVPG FRS2GFW324UNVPG 74.0% 62.2% 66.0% 70.0% 2-TT5 2-6" U T8 2-T5HO 3-T5H0 25W 24W 24W Ordering information FR S 2 G Ceiling type F Lens style W Family Body style Width FR = FRX S = Static 2 = 2 Foot G = Standard Grid F = Frost White W = White 15/16" or 9/16" Acrylic ceiling type Reflector Lamp qty Lamps 2 = 2 Lamp 3 = 3 Lamp FT = TT5 120 = 120V See page 4.128 See page 4.128 6U = 6" U T8 277 = 277V and page 4.130 14 = 14W T5HO UNV= 120-277V 24 = 24W T5HO Voltage Ballast Options (Nominal 24") 4.128 Philips Lightolier For complete specification information visit www.lightolier.com Standard – Linear recessed and surface lighting FRX 2' x 2' Recessed luminaires Comprehensive lighting catalog 7th Edition 4.129 Linear recessed and surface lighting Options & accessories Fluorescent lenses, diffusers, louvers and recessed luminaire options VA VY VI Philips Lightolier Standard Shielding. Extruded virgin acrylic, Excellent obscuration and control (similar to K12). .125" 3/16" square based female cones, running 45° to the panel nominal thickness, extruded virgin acrylic lens, (average edge. .095" nominal thickness (similar to pattern 12). weight per square foot is 7.8 ounces). Economy with more rigidity. .125" nominal thickness, extruded virgin acrylic lens, (average weight per square foot is 6.8 ounces). Catalog no. Substitute: SPS2GFS VA 332UNVH3. Catalog no. Substitute: SPS2GFS VI 332UNVH3. KA Catalog no. Substitute: SPS2GFS VY 332UNVH3. MC BP Extruded acrylic, square base male conical prism. .156" overall thickness (similar to K19 pattern). Injection molded acrylic parabolic louver, 1 ½" x 1 ½" x 1" cell size, with silver specular protected by a clear acrylic. Injection molded polystyrene plastic, parabolic louver. ½" x ½" x ½" cell size, with metallized specular finish. Catalog no. Substitute: SPS2GFS KA 332UNVH3. Catalog no. Substitute: SPS2GFS MC 332UNVH3. Catalog no. Substitute: SPS2GFS BP 332UNVH3. For additional shieldings, consult your local Philips Lightolier Representative. Lamps installed Internal fusing Radio interference filter Consult factory after ascertaining wattage, diameter, color rendering, color temperature. A = Internal fast-blow fusing. C = Internal slow-blow fusing. R = Inductive capacitor circuit designed to minimize interference from line radiation or feedback. e.g: SPS2GFSVA332UNVH3 A 120 or 277 volt at 50 or 60Hz. e.g: DPA2G18LS332120O3 R (one per fixture R) Fluorescent emergency lighting system EM = EM Factory-installed emergency power battery pack with charger and inverter, B100 or equal, 120V or 277V. e.g: SPS2GFSVA332120O3 EM e.g: DPA2G18LS332120SO B (one per ballast B) Prewiring FF6; FF14 3/8" factory prewired cable wired into fixture. Configurations available in various wire gauges, numbers of wires and lengths up to 6'. e.g: DPA2G18LS332UNVH3 FF6 (3 #18 AWG leads, 6' long); e.g: e.g: DPA2G18LS332INVHI FF14 (4 #18 AWG leads, 6' long). e.g: DPA2G18LS332120SOEM FF92 (5 #18 AWG leads, 6' long). 4.130 Philips Lightolier Job-packed Flange kit J = Uncartoned fixtures on pallets are secured by heavy-duty corrugated protectors. Attaches to Philips Lightolier recessed bodies, except XP and XA. For continuous rows, half-width flanges are required between fixtures. 2 x 4 = S2X4F Kit 2 x 2 = S2X2F Kit 1 x 4 = S1X4F Kit see folio OA30-30 2' = 2FCTrim 1' = 1FCTrim 31" x 50" x 78" e.g: DPA2G18LS332UNVH3 J * Consult factory for quantities Radio frequency shielding For hospitals, TV stations or wherever sensitive electronic equipment is in use. Consult factory. For complete specification information visit www.lightolier.com Linear recessed and surface lighting M/S interties Quick connect interties for master/satellite troffers Master/satellite troffers are quoted as a single line item, but are shipped as 3 line items to a job, the Master Troffer, the Satellite Troffer and the Intertie. All are bulk packed. This requires writing 3 separate line items. The following is the method for the proper Catalog number. Features • Quick connect plug-in. • Snap-in access plate for easy connection. • Polarized nylon plugs for positive error free connections. • 90° connectors fit shallow plenums. • Reduced installation labor costs. • Fits CF, DP, SP, MP, LC, LI, MB, PP, PR, VP, XP, XA and VR troffer families. • Master/satellite requires fewer ballasts reducing energy costs. M/S Interties Master Satellite for: CF, DP, SP, MP, LC, LI, PP, PR, VP, XP, XA and VR Series Instant start (1) 2 lamp electronic ballast INT09I2XXXX 2-1 Lamps Units INT11I2XXXX 2-1 Lamps Units 9' length 11' length Instant start (1) 4 lamp electronic ballast INT09I4XXXX 2-2 Lamps Units INT11I4XXXX 2-2 Lamps Units 9' length 11' length Typical Master Troffer Catalog no. (e.g: Deepcel Family = DPA2G18LS332120SO2XX) DPA2G18LS Instant start (1) 4 lamp and 2 lamp electronic ballast INT09I42XIO 2-3 Lamps Units 9' length INT11I42XIO 2-3 Lamps Units 11' length Program start (1) 2 lamp Aelectronic ballast A B B A B B A INT09P2XXXX 2-1 Lamps Units INT11P2XXXX 2-1 Lamps Units 9' length 11' length Program start (1) 4 lamp electronic ballast INT09P4XXXX 2-2 Lamps Units INT11P4XXXX 2-2 Lamps Units 9' length 11' length A B A A Lamp Lamp Ballast Ballast Qty Type Voltage Type Qty (1' x 4' only) 2 = 2 Lamp 32 = T8 120 = 120V SO = 20THD 2X = 1-2 Lamp (2' x 2'/2' x 4') 3 = 3 Lamp 277 = 277V HI = 10THD 22 = 2-2 Lamp 4 = 4 Lamp 4X = 1-4 Lamp 42 = 1-2 Lamp & 1-4 Lamp B A B A B A (IS only) 44 = 2-4 Lamp (IS only) Typical Satellite catalog no. (e.g: Deepcel Family = DPA2G18LS332XXXSO42X) Instant start (2) 2 lamp electronic ballast for tandem Inline DPA2G18LS)s refforT pmaL-2 '4 x '2( )s refforT pmaL-2 '4 x '2( )s refforT pmaL-2 '4 x '1( )s refforTpmaL-1 '4 x '1( )s refforT pmaL-3 '4 x '2( )s reLamps fforT pmUnits aL-4 '4 x '2( INT09I22XTI 2-2 9' length tsallaB pmaL 2-1 )A( tsallaB pmaL 2-1 tsallaB pmaL 4-1 tsallaB pmaL 4-1 )A( tsallaB pmaL 4-1 INT11I22XTI 2-2 Lamps Units 11' length)B( tsallaB pmaL 2-1 No Ballast in Must match ballast quantity nO spmaL llA=XX )B( tsallaB pmaL 2-1 nO spmaL llA=XX nO spmaL llA=XX )A( tsallaB pmaL 4-1 )B( tsallaB pmaL 4-1 Ballast code in master troffer enilni mednaT= ITmaster troffer nO spP maL draobtuO/draobnI=OI nOin spm aL draobtinline uO/drareplace obnI=OI I with Program start also available tandem SO = 20THD Catalog number (e.g: INTO9P22XT I ). A B A A B A HI = 10THD Master/Satellite troffer layouts A B A B (1' x 4' 1-LampTroffers) (1' x 4' 2-Lamp Troffers) 1-2 Lamp Ballast 1-4 Lamp Ballast XX=All Lamps On XX=All Lamps On A B A (2' x 2' 2-Lamp Troffers) B A 1-4ALamp Ballast XX=All Lamps On A B A B A A B A )s refforT pmaL-3 '2 x '2( )B( tsallaB pmaL 2-1 )A( tsallaB pmaL 4-1 nO spmaL draobtuO/draobnI=OI A )s refforT pmaL-2 '4 x '2( )A( tsallaB pmaL 2-1 )B( tsallaB pmaL 2-1 enilni mednaT= IT B (2' x 4' 2-Lamp Troffers) 1-4 Lamp Ballast XX=All Lamps On )s refforT pmaL-2 '4 x '2( tsallaB pmaL 4-1 nO spmaL llA=XX (2' x 4' 2-Lamp Troffers) 1-2 Lamp Ballast (A) 1-2 Lamp Ballast (B) TI =Tandem inline A B B A A B B A )s refforT pmaL-2 '2 x '2( tsallaB pmaL 4-1 nO spmaL llA=XX (2' x 4' 3-Lamp Troffers) 1-2 Lamp Ballast (B) 1-4 Lamp Ballast (A) IO=Inboard/Outboard Lamps On (2' x 4' 4-Lamp Troffers) 1-4 Lamp Ballast (A) 1-4 Lamp Ballast (B) IO=Inboard/Outboard Lamps On forTBpmAaL-1 '4 xA '1B( A )s refforT pmaL-2 '4 x '1( )s refA tsallaB pmaL 2-1 tsallaB pmaL 4-1 nO spmaL llA=XX nO spmaL llA=XX (2' x 2' 3-Lamp Troffers) 1-2 Lamp Ballast (B) 1-4 Lamp Ballast (A) IO=Inboard/Outboard Lamps On Comprehensive lighting catalog 7th Edition )s refforT pmaL-3 '2 x '2( )B( tsallaB pmaL 2-1 )s refforT pmaL-2 '2 x '2( tsallaB pmaL 4-1 4.131 Linear recessed and surface lighting – Professional Wal-Lyter high performance 2' & 4' Recessed wall washer/accent luminaires Wal-Lyter is a high performance wall-washer that delivers an exceptionally even wash of light from the ceiling line to the floor line utilizing TT5 (Biax Type) compact fluorescent lamps. It is much more efficient and more cost effective than most incandescent units producing equivalent illumination. Wal-Lyter is ideal for highlighting merchandise displays, brightening the walls in offices illuminating with sharp cut-off parabolics and for many other wall lighting applications. Features • Low iridescent specular reflector system for precise controlled light output. • Evenly lights vertical surfaces or displays. • 87% energy savings vs. incandescent. • 1,250 lumen (18 watt), 3150 lumen (40 watt) Biax type lamp requires fewer fixtures to provide the same wall illumination as a 60 watt incandescent wallwasher. • 20,000 hours lamp life requires less maintenance than incandescent wallwasher. WLRN124UNVPR 10 1316" (275mm) • One-piece body and integral hanger for easy, quick installation. 10 1316" (275mm) • Meets NYC Code requirements. Lens • WLRK lens, extruded acrylic (similar to K19 pattern), see page 4.130. page 4.130 PowerSpec HDF dimming BA 24W TT5 BB 40W TT5 IB*, PR** 50W TT5 BE 55W TT5 BF 40W TT5 PB With lens cat. no. WLRN121 WLRN122 WLRN124 WLRN125 WLRN126 WLRK121 WLRK122 WLRK124 WLRK125 WLRK126 10 1316" (275mm) 1800 Ordering information 4 716" (113mm) Lamps qty –type 10 1316" (275mm) Radio interference filter: Suffix: R. 120 or 277 volt at 50 or 60Hz. Lens Fusing: Suffix: A (Internal fast-blow fusing). Suffix: C (Internal slow-blow fusing). 2-TT5 4 716" (113mm) 7 1316" (183mm) Opening Chicago Plenum: Consult factory. Lamp watts 18W 24W 40W 50W 55W With lens cat. no. WLRN241 WLRN242 WLRN244 WLRN245 WLRN246 WLRK241 WLRK242 WLRK244 WLRK245 WLRK246 Nominal Length 48" Units 7 1316" (183mm) Opening 10 1316" (275mm) Lens 4 716" (113mm) 7 1316" (183mm) Opening 4.132 Philips Lightolier 2-TT5 Twin tube 18W Nominal Length 48" Units Integral hanger fixture: installs easily with adjustable integral hanger that clamps to T bar. Wire fixture through access plate without opening lamp compartment. Candlepower Curve No lens cat. no. With lens cat. no. WLRN241 – – WLRK241 60˚ 1200 2400 3600 30˚ Footcandles on wall fixtures: 3 feet from wall to outside trim on lamp side of fixture (without lens) Ordering information Lamp watts Candlepower Curve No lens cat. no. WLRN241UNVPR Lamps qty –type 30˚ 4' fixture, 2 lamp 40 watt TT5 7 1316" (183mm) Opening Electrical/wiring options: For special wiring, fusing, electronic dimming ballasts, consult factory. 4 716" (113mm) 1200 Individual Wal-Lyter Multiple Units 0' 1' 2' 3' 4' 5' 6' 7' 8' 4' 6' Ceiling 8' 76 67 46 25 14 8 5 4 3 107 104 102 104 107 86 79 63 50 63 79 86 7' 64 60 46 29 17 10 7 5 4 102 104 106 104 102 78 75 67 58 67 75 78 6' 47 44 36 24 17 12 8 6 4 85 86 88 86 85 63 62 57 48 57 62 63 5' 33 34 29 24 14 10 8 6 5 66 74 74 74 66 49 50 48 48 48 50 49 4' 26 28 23 20 14 11 8 6 5 59 65 62 65 59 42 45 42 40 42 45 42 3' 19 21 20 17 12 9 8 6 5 48 53 56 53 48 35 36 37 34 37 36 35 2' 15 16 15 13 11 9 8 6 5 42 44 46 44 42 31 31 31 26 31 31 31 1' 13 12 11 11 10 8 7 6 5 38 37 36 37 38 28 26 26 22 26 26 27 Floor Drywall kit: Catalog no. WL2DF/ UNV with 2' fixtures and WL4DF/ UNV with 4' fixtures. 10 1316" (275mm) 60˚ 600 Nominal Length 24" Units WLRN244UNVPR * Instant start. ** Program start. 1-TT5 18W 24W 40W 50W 55W Candlepower Curve No lens cat. no. Footcandles on wall: Fixtures 3 feet from wall to outside trim on lamp side of fixture (without lens) Ballast type 18W TT5 Lamp watts 4 716" (113mm) 7 1316" (183mm) Opening Ballast: Specify voltage (120, 277 or UNV) and type and add as suffix, e.g. 120SB. Electronic Lamps qty –type 7 1316" (183mm) Opening • UL-Listed access plate. Options & accessories Ordering information 4 716" (113mm) • Fits all lay-in grid ceiling systems. 2' fixture, 1 lamp 40 watt TT5 1200 60˚ 2400 3600 Example Individual Wal-Lyter 0' 1' 2' 3' 4' 5' 6' 7' 8' Ceiling 8' 111 101 75.5 47.8 28.3 18.1 13.2 10.4 8.7 7' 113 104 81.7 55.7 35.5 23.5 16.6 12.5 9.8 6' 86.4 81.0 66.9 49.8 34.8 24.6 17.7 13.4 10.4 5' 62.5 59.1 51.4 41.6 31.9 24.3 18.4 13.9 10.7 4' 50.5 48.6 42.9 35.6 28.7 22.6 18.0 14.3 11.1 3' 39.7 38.5 34.9 30.0 25.1 20.6 16.9 14.1 11.4 2' 31.1 30.3 28.1 25.0 21.7 18.5 15.7 13.4 11.1 1' 24.2 23.6 22.5 20.8 18.7 16.6 14.6 12.8 11.0 Floor 30˚ WLRN124 Wal-Lyter High Performance Wall Washer UNV PR Voltage Ballast 120 = 120V See page 4.132 277 = 277V UNV= 120-277V A Options See page 4.132 and page 4.130 For complete specification information visit www.lightolier.com Specification – Linear recessed and surface lighting Walmaster 2' & 4' Recessed wall washer/accent luminaires Walmaster is a high performance luminaire with low-iridescence semi-specular reflectors that do not protrude below the ceiling line. This provides a clean appearance while controlling the light output of a T8 or TT5 (twin tube) lamp to illuminate vertical surfaces uniformly. 2' fixture, 1 lamp 40 watt TT5 Ordering information 4 716" (113mm) Lamps qty –type 7 ⅞" (178mm) 24" (610mm) • Low iridescent specular reflector system for precise controlled light output. • Evenly lights vertical surfaces or displays (no scallops). WMRL124UNVPR 10mm) Features Candlepower Curve Lamp Catalog watts number 18W 24W 716" 1-TT5 440W (113mm) 50W 55W 7 ⅞" • 87% energy savings vs. incandescent. • Less than 3:1 maximum to minimum wall illumination when installed 6 feet on center. • 20,000 hours lamp life requires less maintenance than incandescent. 60˚ 600 WMRL121 WMRL122 WMRL124 WMRL125 WMRL126 • Can be installed only 2 feet from wall to farthest edge of fixture (3' maximum). 1200 (178mm) Nominal Length 24" Units • No edges protrude below ceiling line. • Fits all standard and narrow grid ceiling systems. 1800 30˚ • One-piece body and integral hanger for easy, quick installation. • Sides of fixture can support tile or sit on T-bar. • UL Listed access plate. • Meets NYC Code requirements. Options & accessories page 4.130 Ballast: Specify voltage (120, 277 or UNV) and type and add as suffix, e.g. 120SB. Ballast type WMRL244UNVPR 4' fixture, 2 lamp 40 watt TT5 7 ⅞" (178mm) 7 ⅞" (178mm) 48" (1220mm) 48" (1220mm) 2400 4 " (113mm) Individual Wal-Lyter 0' 1' 2' 3' 4' 5' 6' 7' Ceiling 8' 49 38 21 12 8 5 4 3 7' 49 42 29 18 12 8 6 4 6' 36 33 25 18 12 8 6 5 5' 27 25 21 16 12 9 7 5 4' 21 20 17 14 11 8 7 5 3' 16 16 14 12 9 8 6 5 2' 13 13 12 10 9 7 6 5 1' 11 10 10 9 8 6 6 5 Floor Lamps qty –type 1-T8 Lamp Catalog watts number 32W WMRL143 30˚ Candlepower Curve 60˚ 550 1100 1650 30˚ Nominal Length 48" Units Example WMRL124 Walmaster High Performance Wall Washer T8 PS † PB 40W TT5 IB*, PR** 50W TT5 BP 55W TT5 BF † 4' unit only Drywall kit: Catalog no. WL2DF/UNV with 2' fixtures and WL4DF/UNV with 4' fixtures. Fusing: Suffix: A (Internal fast-blow fusing). Suffix: C (Internal slow-blow fusing). 7 ⅞" (178mm) Ordering information 40W TT5 BB Electrical/wiring options: For special wiring, fusing, electronic dimming ballasts, consult factory. 4 " (113mm) 48" (1220mm) BA 24W TT5 * Instant start. 3600 7 16 48" (1220mm) 18W TT5 ** Program start. 4' fixture, 1 lamp 32 watt T8 7 16 PowerSpec HDF dimming T8 HI* WMRL143UNVHI 7 ⅞" (178mm) 60˚ 1200 48" (1220mm) Individual Wal-Lyter Ordering information 0' 1' 2' 3' 4' 5' 6' 7' 8' Lamps Lamp Catalog Ceiling qty –type watts number 8' 116 88 51 30 19 13 13 10 8 7' 119 102 71 45 29 19 19 14 11 18W WMRL241 6' 92 83 64 45 31 22 22 16 12 5' 69 64 53 40 30 22 22 16 13 24W WMRL242 4' 52 50 43 35 27 21 21 17 13 2-TT5 40W WMRL244 3' 40 39 35 30 24 19 19 16 13 50W WMRL245 2' 32 31 29 25 21 17 17 15 12 55W WMRL246 1' 26 25 23 21 18 15 15 13 12 Floor Nominal Length 48" Units 48" (1220mm) Candlepower Curve 4 716" (113mm) 4 716" (113mm) Electronic UNV PR Voltage Ballast 120 = 120V See page 4.133 277 = 277V UNV= 120-277V Drywall kit: WL2DF/UNV with 2' fixtures WL4DF/UNV with 4' fixtures Integral Hanger Fixture: installs easily with adjustable integral hanger that clamps to T bar. Wire fixture through access plate without opening lamp compartment. A Options See page 4.133 and page 4.130 Comprehensive lighting catalog 7th Edition 4.133 Linear recessed and surface lighting – Specification Bi-lyter 2' & 4' Surface wall washer or indirect wall mount luminaires BLSF124120SB Ceiling Ordering information Lamp watts Catalog number 1-TT5 18W 24W 40W 50W 55W BLSF121 BLSF122 BLSF124 BLSF125 BLSF126 48" 2-TT5 18W 24W 40W 50W 55W BLSF241 BLSF242 BLSF244 BLSF245 BLSF246 48" 1-T8 32W BLSF143 Length 4" (102mm) 24" 4 ⅜" (111mm) Wall washer )mm111( "⅜ 4 Wall Features 4 ⅜" (111mm) • Same fixture can be used as a wall washer when ceiling mounted, or for indirect lighting when wall mounting. "4 )mm201( Bi-lyter Surface Wall or Ceiling Mounted 4" (102mm) • Soft rounded corners and edges create an elegant appearance. BLSF124 Example • Only 4" deep. • Meets ADA when wall mounted. Candlepower Curve Lamps qty –type Indirect wall mount 120 60˚ 400 800 30˚ SB Voltage Ballast 120 = 120V See page 4.134 277 = 277V UNV= 120-277V A Options See page 4.134 and page 4.130 For flat white finish order BLSF. (e.g: BLSF126120SB) • 20 gauge cold rolled steel body. • Specular reflector. • No visible hardware. Footcandles on wall: Fixtures 3 feet from wall to outside trim on lamp side of fixture (Wall Washer) • 4' unit 2-TT5 or 1-T8 lamp. • 2' unit TT5 lamp. • Flat white baked acrylic finish (standard). • Can be used in continuous rows. Consult factory. • Meets NYC Code requirements. Options & accessories page 4.130 Ballast: Specify voltage (120, 277 or UNV) and type and add as suffix, e.g. UNVHI. Ballast type <10THD <20THD TT5 IB* SB T8 HI* SO* * 4' unit only Electrical/wiring options: For special wiring, fusing, electronic dimming ballasts, consult factory. Individual Wal-Lyter Multiple Units Continuous Row 0' 1' 2' 3' 4' 5' 6' 7' 8' 4' 6' 0' 1' 2' 3' 4' 5' 6' 7' 8' Ceiling 8' 4 5 6 9 14 25 46 72 86 100 98 92 98 100 93 82 60 50 60 82 93 157 184 199 204 207 204 199 184 157 7' 4 5 6 9 14 24 40 60 70 83 84 81 84 83 76 69 54 47 54 69 76 134 158 170 176 178 176 170 158 134 6' 4 5 6 9 13 20 31 42 47 59 63 63 63 59 53 51 44 41 44 51 53 101 118 128 134 135 134 128 118 101 5' 4 5 6 7 10 16 22 27 30 40 43 43 43 40 35 35 32 31 32 35 35 71 82 89 93 94 93 89 82 71 4' 3 4 5 6 8 10 13 15 17 24 26 26 26 24 21 21 21 21 21 21 21 45 51 55 57 58 57 55 51 45 3' 3 3 4 5 6 7 8 9 9 15 16 16 16 15 13 14 14 14 14 14 13 30 33 35 36 36 36 35 33 30 2' 3 3 3 4 4 5 5 6 6 10 10 11 10 10 9 9 9 9 9 9 9 21 23 24 25 25 25 24 23 21 1' 2 3 3 3 3 4 4 4 4 8 8 8 8 8 7 7 7 7 7 7 7 17 17 18 18 19 18 18 17 17 Floor Small office application Only four By-Lyters 55 watt lamp are required to illuminate a 12' x 12' (80/80/50) office space to 50 maintained footcandles with only 1.68 watts per square foot. 2" Unit Fusing: Suffix: A (Internal fast-blow fusing). Suffix: C (Internal slow-blow fusing). ⅞" (22mm) 932" (7mm) Dia K.O. Mounting Hole 4 ⅜" (111mm) Wall mount spacer: Order BL spacer. For uneven walls or a floating visual effect. 6 1116" 8 ¾" (222mm) (170mm) 25 1516" (659mm) Continuous row coupler: Order BL coupler. T-Grid mounting: Order BL mount. 4" Unit ⅞" (22mm) Dia K.O. 9 1516" (252mm) Mounting Holes 4 ⅜" (111mm) 20 ⅛" (511mm) 22 1316" (579mm) 4.134 Philips Lightolier 10" (254mm) 49 1516" (1268mm) Luminaire: mounted 18" from ceiling 12' x 12' Office Space with a 9' Ceiling Height Reflectance: 80% Ceiling, 80% Wall, 50% Floor. Reported numbers are maintained footcandles at desk top level with 55 watt lamp. Footcandle readings will vary depending on room reflectance. For complete specification information visit www.lightolier.com Medical luminaires Contents MD*4 & MD*2 > 4.138 MD* Coffer > 4.140 MD*A Assymetric > 4.142 OBL & SUS 432/632 > 4.144 Comprehensive Lighting Catalog 7th Edition 4.135 Linear recessed and surface lighting – Specification Medical luminaires Hospital patient room lighting Philips Lightolier’s MD* series luminaires combine all of the lighting functions in a patient’s room into a single, ceiling-mounted luminaire. Removing lighting from walls and other locations where it may be interfering with equipment and prone to damage. It supports a friendly and more residential design for the entire room. MD*4 installs at the edge of the ceiling and provides ambient, reading, examination, and night lighting – all from carefully shielded sources. MD*Coffer installs 12-18" from the wall and provides the same lighting functions, using an indirect coffer for the ambient and reading light. 4.136 Philips Lightolier For complete specification information visit www.lightolier.com Specification – Linear recessed and surface lighting Medical luminaires Hospital patient room lighting MD* Coffer • Indirect ambient light with perforated mesh shield. • Precise light control for glare-free patient environment. • Four integral lighting functions: indirect ambient, direct reading, examination and optional night light. • Recessed or surface mounted to ceiling which eliminates damage to fixture from hospital equipment attached to patient's bed. • Installs as a one-piece unit. Lighted Zone • Optional low voltage electronic sequential switch mounted in fixture for ambient and reading light controlled with pillow speaker (optional by others). • Meets NYC Code requirements. Chicago Plenum requirements available. . MD* Coffer style • 6 ⅞" deep. • All lamps are shielded. • All twin tube T5 lamps are accessible for relamping without tools. Lighted Zone Lighted Zone MD*4 Series • Four lighting functions with integral ambient, reading, examination and optional night light. • Installs as a one-piece unit. • Precise light control for glare free patient environment. • Recessed or surface mounted to ceiling against wall directly behind patient which eliminates damage to fixture from hospital equipment attached to patients bed. • Optional low voltage electronic sequential switch mounted in fixture for ambient and reading light controlled with pillow speaker (optional by others). MD*4 Style 3 (AW option) • Meets NYC Code requirements. Chicago Plenum requirements available. For single patient room All components white • 6 ⅞" deep. • All lamps are enclosed. • All twin tube T5 lamps are accessible for relamping without tools. MD*4 Style 2 (FF option) White louver and horizontal surfaces to blend with ceiling Optional LED Night Light Night Light: 120V or 277V, 3 watt, cool white LED (50,000 hours life - supplied with fixture). For multiple patient room Suffix: LD (available on MD*4 only). Lighted Zone Shielded Zone Lighted Zone Shielded Zone Lighted Zone Comprehensive lighting catalog 7th Edition 4.137 Linear recessed and surface lighting – Specification MD*4 series 2' x 4' Multi-function patient room luminaire (ambient/reading/examination/nurse’s night light) MD*4 combines all of the lighting functions in a patient’s room in a single luminaire that is ceiling mounted to permit clean headwalls. This enables architects and interior designers to create a more home-like environment and moves the light luminaire off the wall, a location where it can be damaged easily or interfere with medical equipment. MD*4 is more efficient and more economical than all other patient lighting systems. Features • 2 x 4 Unit has four lighting functions with integral ambient, reading, examination and optional nurse’s night light. MD*4 2' x 4' Ceiling • Specular aluminum reflectors for precise light control and glare free patient environment. 6 ⅞" (175mm) • Installs as a one-piece unit. Recessed or surface mounted to ceiling against wall directly behind patient. Wall Secure Luminaire (4 Places) 48" (1220mm) • Eliminates damage to luminaire from hospital equipment attached to patient bed. Wall angle or T-bar by others • 6 ⅞" deep. • Top wiring access plate is standard. Wall • All lamps are enclosed. • All TT5 type lamps (not included) are accessible for relamping without tools. • Rugged 20 gauge steel housing. • Optional low voltage (1-3 volts) electronic sequential switch mounted in luminaire for ambient and reading light controlled with pillow switch (by others). • Examination Light in 2 x 4 has 36 cell specular aluminum parabolic louver with pattern 12 lens overlay. Options & accessories Electronic (low voltage) sequential switch: Switch factory mounted in luminaire for ambient and reading light convenience (controlled by pillow switch, by others). Suffix: SW. Nurse night light: 120V medium base, narrow spot, 50W PAR 20 reflector lamp included with specular anodized mirror, field adjustable to right or left side of patients bed. Suffix: NL. The LED Night Light 120Volt, 3W, cool white LED (50,000 hours life - supplied with fixture). Suffix: LD Electrical/wiring options: For special wiring, fusing, electronic dimming ballasts, consult factory. Fusing: Suffix: A (Internal fast-blow fusing). Tamper proof: Order Germ Shield. Germ shield: Order Cat. no., MD4CLGS24 (2x4). Germshield can only be used with recessed MD*4. Examination light • Excellent color rendition. (82 CRI TT5 Type lamp). Footcandles on Bed (with Specular Louver) (Totals of Ambient, Reading & Examination lights) • Wired for independent switching (1 or 2 circuit). Numbers in parenthesis ( ) are total footcandle level of ambient and reading lights only. Reading light • Eliminates reflected glare from reading material (over the shoulder illumination). Footcandles on Beds (Horizontal) Reading Light/On Adjacent MD*4 Off 3" 6" • No direct glare to patient or visitors. (7 footcandles maximum at head of bed. 15 footcandles maximum at foot of bed.). • Controls light directly onto patients bed. • No reading light spill-over to adjacent beds. (1 footcandle maximum at head of adjacent patient’s bed.) 2 2 2 2 WALL 2 1 1 1 1 1 1 3 3 3 3 3 2 2 2 1 1 1 1 6 7 7 7 6 4 3 3 2 2 1 1 33 38 39 38 33 23 16 12 9 5 3 2 30 38 38 38 30 23 15 12 8 6 3 2 14 15 15 15 14 11 9 7 5 4 2 2 5 5 5 5 5 4 4 2 2 1 1 5 BED BED Type Cells MD*4 2x4 Ambient, Reading and Examination Light Examination light shielding 3" 2 Ordering information Sequential switch (SW) 48" (1220mm) Acoustical tile by others Lamps qty –type* Ballast type 6" 12" Illumination at the reading task ranges 50-80 footcandles. 12" Grid ceiling 36 Traditional Specular Louver 6-TT5 5-TT5 40W Electronic MD4GPSVA2SB4SB MD4GPSVA2SB3SB 36 Louver with all White Components 6-TT5 5-TT5 40W Electronic MD4GAWVA2SB4SB MD4GAWVA2SB3SB 36 White Louver with White Horizontal Surface 6-TT5 5-TT5 40W Electronic MD4GFFVA2SB4SB MD4GFFVA2SB3SB * Include 2-TT5 for ambient / reading section. Example MD4GPSVA2SB4SB MD*4 Multi-function Examination Luminaire 4.138 Philips Lightolier 120 SW A Voltage Options Options Options 120 = 120V SW= Electronic LD = 3W LED See page 4.138 277 = 277V Sequential Switch Nurses Night Light For complete specification information visit www.lightolier.com Specification – Linear recessed and surface lighting MD*2 series 2' x 2' Multi-function patient room luminaire (ambient/reading/nurse’s night light) MD*4 combines all of the lighting functions in a patient’s room in a single luminaire that is ceiling mounted to permit clean headwalls. This enables architects and interior designers to create a more home-like environment and moves the light luminaire off the wall, a location where it can be damaged easily or interfere with medical equipment. MD*4 is more efficient and more economical than all other patient lighting systems. Features MD*2 2' x 2' 2 types of lighting: ambient & reading Ceiling 6 ⅞" (175mm) Secure Luminaire (4 Places) Wall angle or T-bar by others Wall 24" (610mm) Wall Acoustical tile by others 24" (610mm) • 2 x 2 Unit has three lighting functions with integral ambient, reading, and optional nurse’s night light. • Specular aluminum reflectors for precise light control and glare free patient environment. • Installs as a one-piece unit. Recessed or surface mounted to ceiling against wall directly behind patient. • Eliminates damage to luminaire from hospital equipment attached to patient bed. • 6 ⅞" deep. • Top wiring access plate is standard. • All lamps are enclosed. Ambient light Ambient Light/On • All TT5 type lamps (not included) are accessible for relamping without tools. Adjacent MD*4/Off • Indirect illumination from wall directly behind patient provides glare-free lighting. • Rugged 20 gauge steel housing. • Optional low voltage (1-3 volts) electronic sequential switch mounted in luminaire for ambient and reading light controlled with pillow switch (by others). • No direct glare to patient (Light is directed towards wall). • No direct glare to patients visitor. Options & accessories • No direct glare to adjacent patients. (3 footcandles maximum on wall behind adjacent patient’s bed.) Electronic (low voltage) sequential switch: Switch factory mounted in luminaire for ambient and reading light convenience (controlled by pillow switch, by others). Suffix: SW. Reading light Footcandles on Beds (Horizontal) • Eliminates reflected glare from reading material (over the shoulder illumination). 3" 6" • No direct glare to patient or visitors. (7 footcandles maximum at head of bed. 15 footcandles maximum at foot of bed.). • Controls light directly onto patients bed. • No reading light spill-over to adjacent beds. (1 footcandle maximum at head of adjacent patient’s bed.) Reading Light/On Reading Light/On Adjacent MD*4/Off Adjacent MD*4 Off 2 2 2 2 2 WALL 2 1 3 3 3 3 3 2 2 2 1 1 1 1 6 7 7 7 6 4 3 3 2 2 1 1 33 38 39 38 33 23 16 12 9 5 3 2 30 38 38 38 30 23 15 12 8 6 3 2 14 15 15 15 14 11 9 7 5 4 2 2 5 5 5 5 5 5 4 4 2 2 1 1 1 1 1 1 BED Illuminating at the reading task ranges 50-60 footcandles BED 3" 6" 12" Illumination at the reading task ranges 50-80 footcandles. Nurse night light: 120V medium base, narrow spot, 50W PAR 20 reflector lamp included with specular anodized mirror, field adjustable to right or left side of patients bed. Suffix: NL. The LED Night Light 120Volt, 3W, cool white LED (50,000 hours life - supplied with fixture). Suffix: LD Electrical/wiring options: For special wiring, fusing, electronic dimming ballasts, consult factory. Fusing: Suffix: A (Internal fast-blow fusing). Tamper proof: Order Germ Shield. Germ shield: Order Cat. no., MD4CLGS22 (2x2). Germshield can only be used with recessed MD*2. 1 12" Ordering information Type MD*2 2x2 Ambient and Reading Light Example Lamps qty –type Ballast type Grid ceiling 2-TT5 40W Electronic MD2G2SB MD2G2SB MD*2 Multi-function Patient Luminaire 120 SW Voltage Options 120 = 120V SW= Electronic 277 = 277V Sequential Switch A Sequential switch (SW) Options Options LD = 3W LED See page 4.139 Nurses Night Light Comprehensive lighting catalog 7th Edition 4.139 Linear recessed and surface lighting – Specification MD* Coffer 2' x 4' Multi-function patient room luminaire (ambient/reading /examination /nurse’s night light) MD* Coffer combines all of the lighting functions in a patient’s room in a single luminaire that is ceiling mounted to permit clean headwalls. This enables architects and interior designers to create a more home like environment and moves the light luminaire off the wall, a location where it can be damaged easily or interfere with medical equipment. MD*Coffer is more efficient and more economical than all other patient lighting systems. Features • 2 x 4 Unit has four lighting functions with integral ambient, reading, examination and optional nurse’s night light. MD*Coffer 2' x 4' • Specular aluminum reflectors for precise light control and glare free patient environment. Mount 12" - 18" from wall 6 ⅞" (175mm) • Installs as a one-piece unit. Recessed or surface mounted to ceiling against wall directly behind patient. 48" (1220mm) 9'6" max. mounting height • Eliminates damage to luminaire from hospital equipment attached to patient bed. Wall angle or T-bar by others • Top wiring access plate is standard. • Optional low voltage (1-3 volts) electronic sequential switch mounted in luminaire for ambient and reading light controlled with pillow switch (by others). • Examination Light in 2 x 4 has 36 cell flat white baked enamel louver with pattern 12 lens overlay. Ambient light • Indirect illumination from TT5 shielded by perforated mesh shield with white acrylic overlay. 3" from Wall • Rugged 20 gauge steel housing. Secure Luminaire (4 Places) Mount 12" - 18" from wall 48" (1220mm) Wall • All TT5 type lamps (not included) are accessible for relamping without tools. All lamps are enclosed. Lighted Zone Ceiling Wall Acoustical tile by others 6" 12" Bed 14 15 15 14 12 12 7 • Perforated mesh shield for ambient / reading section. • No direct glare to patient. 14 16 16 14 12 12 8 Options & accessories • No direct glare to patients visitor. • No direct glare to adjacent patients. 14 15 15 14 12 12 7 Electronic (low voltage) sequential switch: Switch factory mounted in luminaire for ambient and reading light convenience (controlled by pillow switch, by others). Suffix: SW. 9/7 Watt night light: Suffix: PL (Lamp not included). Electrical/wiring options: For special wiring, fusing, electronic dimming ballasts, consult factory. Footcandles on Bed Reading light • Eliminates reflected glare from reading material (over shoulder illumination). 3" from Wall 277V: Change 120 to 277 (e.g. MDCGWSVA2SB4SB120, changes to MDCGWSVA2SB4SB277). Lighted Zone • No direct glare to patient or visitors. Illumination at the reading task ranges 45-50 footcandles. 6" 12" Bed 17 21 23 28 33 6 5 18 22 24 29 35 6 5 • Controls light directly onto patient’s bed. 12" 17 21 23 28 33 6 5 Fusing: Suffix: A (Internal fast-blow fusing). Footcandles on Bed Tamper proof: Order Germ Shield. Examination light • Excellent color rendition. Wired for independent switching (1 or 2 circuit). 3" from Wall Germ shield: Order Cat. no., MD4CLGS24 (2x4). Germshield can only be used with recessed MD* Coffer. 12" Lighted Zone • Optional louver or lens frame. • Concealed hinging and latching. Numbers in parenthesis ( ) are total footcandle level of ambient and reading lights only. Bed 68 85 93 99 100 65 49 (31) (36) (38) (42) (45) (18) (12) 12" 73 89 99 104 106 68 53 (32) (38) (40) (43) (47) (18) (13) 6" 12" 68 85 93 99 100 65 49 (31) (36) (38) (42) (45) (18) (12) Footcandles on Bed Ordering information Type Sequential switch (SW) Cells MD* Coffer 2x4 Ambient, Reading and Examination Light 36 Examination light shielding Lamps qty –type* Ballast type 6-TT5 5-TT5 40W Electronic White Louver with Prismatic Overlay Grid ceiling MDCGWSVA2SB4SB MDCGWSVA2SB3SB * Include 2-TT5 for ambient / reading section. Example MDCGWSVA2SB4SB MD* Coffer 2x4 Multi-function Examination Luminaire 4.140 Philips Lightolier 120 SW PL Voltage Options Options 120 = 120V SW= Electronic PL = Nurses 277 = 277V Sequential Switch Night Light A Options See page 4.140 For complete specification information visit www.lightolier.com Specification – Linear recessed and surface lighting MD* Coffer 2' x 2' Multi-function patient room luminaire (ambient/reading /nurse’s night light) MD* Coffer combines all of the lighting functions in a patient’s room in a single luminaire that is ceiling mounted to permit clean headwalls. This enables architects and interior designers to create a more home like environment and moves the light luminaire off the wall, a location where it can be damaged easily or interfere with medical equipment. MD*Coffer is more efficient and more economical than all other patient lighting systems. Features MD*Coffer 2' x 2' 2 types of lighting: ambient & reading 6 ⅞" (175mm) Mount 12" - 18" from wall Wall Ceiling 24" (610mm) 9'6" max. mounting height Secure Luminaire (4 Places) Mount 12" - 18" from wall Wall angle or T-bar by others • Specular aluminum reflectors for precise light control and glare free patient environment. • Installs as a one-piece unit. Recessed or surface mounted to ceiling against wall directly behind patient. 24" (610mm) Wall • 2 x 2 Unit has three lighting functions with integral ambient, reading, and optional nurse’s night light with perforated mesh shield. Acoustical tile by others • Eliminates damage to luminaire from hospital equipment attached to patient bed. • Top wiring access plate is standard. • All TT5 type lamps (not included) are accessible for relamping without tools. All lamps are enclosed. • Rugged 20 gauge steel housing. • Indirect illumination from TT5 shielded by perforated mesh shield with white acrylic overlay. 3" from Wall Ambient light Lighted Zone Bed 14 15 15 14 12 12 7 • No direct glare to patient. 14 16 16 14 12 12 8 • No direct glare to patients visitor. 14 15 15 14 12 12 7 • No direct glare to adjacent patients. • Optional low voltage (1-3 volts) electronic sequential switch mounted in luminaire for ambient and reading light controlled with pillow switch (by others). 6" 12" • Perforated mesh shield for ambient / reading section. 12" 277V: Change 120 to 277 (e.g. MDCGWSVA2SB4SB120, changes to MDCGWSVA2SB4SB277). Footcandles on Bed • Eliminates reflected glare from reading material (over shoulder illumination). 3" from Wall Reading light Lighted Zone • No direct glare to patient or visitors. Illumination at the reading task ranges 45-50 footcandles. 6" 12" Bed 17 21 23 28 33 6 5 18 22 24 29 35 6 5 • Controls light directly onto patient’s bed. 17 21 23 28 33 6 5 Footcandles on Bed 3" from Wall Night light (optional) • Indirect 9 or 7 watt PL lamp shielded by perforated mesh with internal white acrylic overlay. Options & accessories Electronic (low voltage) sequential switch: Switch factory mounted in luminaire for ambient and reading light convenience (controlled by pillow switch, by others). Suffix: SW. 9/7 Watt night light: Suffix: PL (Lamp not included). 12" Electrical/wiring options: For special wiring, fusing, electronic dimming ballasts, consult factory. Fusing: Suffix: A (Internal fast-blow fusing). Tamper proof: Order Germ Shield. Germ shield: Order Cat. no., MD4CLGS22 (2x2). Germshield can only be used with recessed MD* Coffer. 6" 12" Bed 3 4 3 3 2 2 1 • No glare to any patient. 3 4 3 3 2 2 1 • Wired for independent switching. 3 4 3 3 2 2 1 12" Footcandles on Bed Ordering information Type MD* Coffer 2x2 Ambient, Reading Example Lamps qty –type* Ballast type Grid ceiling 2-TT5 40W Electronic MDCG2SB MDCG2SB MD* Coffer 2x2 Multi-function Patient Luminaire 120 SW Voltage Options 120 = 120V SW= Electronic 277 = 277V Sequential Switch Sequential switch (SW) PL Options NL = Nurses Night Light A Options See page 4.141 Comprehensive lighting catalog 7th Edition 4.141 Linear recessed and surface lighting – Specification MD*A 6" x 48" Recessed fluorescent multi-function patient luminaire asymmetric examination and ambient lighting With the ever-increasing amounts of medical equipment needing headwall space and an overall desire to create a comforting, home-like environment, the Philips Lightolier MD*A meets these challenges. The Philips Lightolier MD*A offers three integral lighting functions: ambient light, examination light and an optional wall switch controlled night light. The ambient light provides a soft level of light that is perfect for general illumination. The examination light produces shadow-free illumination over the entire bed. When these two modes are switched on simultaneously, very high light levels are achieved, up to 120 footcandles. Ideally installed in opposing pairs over the bed. The Philips Lightolier MD*A can be ordered as two individual luminaires for wall switch operation. Or as Master and Satellite luminaires utilizing our optional sequential switch, giving the patient the ability to control the aforementioned functions from a pillow switch. Ordering information Explanation of Individual MD*A luminaire Catalog number. Example: MDA6G254117120PGP2 MD*Asymmetric Fixture width MDA 6 Ceiling type Exam lamp G 254 Ambient lamp Voltage Exam ballast Ambient ballast 117 120 PG P2 Explanation of Master MD*A luminaire Catalog number with sequential switch. Example: MDA6G254117120PGP2-SW MD*Asymmetric Fixture width MDA 6 Ceiling type Exam lamp G 254 Ambient lamp Voltage Exam ballast Ambient ballast Sequence switch 117 120 PG P2 SW Explanation of Satellite MD*A luminaire Catalog number with sequential switch. Example: MDA6G254117120PGXX-SW MD*Asymmetric Fixture width MDA 6 4.142 Philips Lightolier Ceiling type Exam lamp G 254 Ambient lamp Voltage Exam ballast Ambient ballast Satellite Sequence switch 117 120 PG P2 XX SW For complete specification information visit www.lightolier.com Specification – Linear recessed and surface lighting MD*A 6" x 48" Recessed fluorescent multi-function patient luminaire asymmetric examination and ambient lighting 42" 36" 20 Gauge steel housing 4 1516" (126mm) Exam light (2) 54w T5HO lamps (by others) Exam & Ambient Exam Ambient light (1) 17W T8 or 24W T5HO (by others) 42" Exam & Ambient Miro 4 reflector 72" 36" Exam Ambient 6" (152mm) Ambient Lens hold down latch Asymmetric prismatic lens 7 8 8 10 11 12 9 10 10 13 15 15 8 10 8 7 11 10 11 15 12 10 16 15 10 10 9 10 9 10 15 13 15 13 15 15 8 8 7 11 10 7 8 8 10 10 16 12 15 15 11 11 10 12 9 10 10T8 10 9 Two10 17W Lamps footcandle levels* 10 8 10 7 8 11 15 13 15 15 13Lamps 15 T5HO Two 24W footcandle levels* 15 11 15 10 12 16 10T8 Lamps 9 Two10 17W footcandle levels* 8 8 7 15 13Lamps 15 T5HO Two 24W footcandle levels* 12 11 10 Two 17W T8 Lamps footcandle 79 79 84 levels* Two 24W T5HO Lamps footcandle 79 79 84 levels* 100 106 99 100 106 99 84 106 79 79 114 106 84 106 79 79 114 106 106 100 99 100 99 106 106 100 99 100 99 106 84 79 79 114 106 79 79 84 106 84 79 79 114 106 79 79 84 106 99 100 106 100 99 106 Four 54W T5HO Lamps footcandle levels* 106 84 106 79 79 114 99 100 106 100 99 106 Four 54W T5HO Lamps footcandle levels* 106 84 106 79 79 114 99 106 100 Four 54W T5HO Lamps footcandle levels* 79 84 79 99 106 100 Four 54W T5HO Lamps footcandle levels* 79 84 79 Four 54W T5HO Lamps footcandle 80 82 89 levels* Four 54W T5HO Lamps footcandle 86 85 92 levels* Full light level output. 101 108 101 104 111 106 • Lens encloses lamps within luminaire. 89 108 80 82 117 108 92 111 86 85 120 111 101 108 101 101 101 108 104 110 106 104 106 111 89 80 82 117 108 82 80 88 108 92 86 85 120 111 85 86 92 111 108 101 101 101 108 101 Two 17W T8 Lamps and Four 54 Watt T5HO 108 117 88 108 82 levels* Lamps,80 footcandle 111 104 106 104 110 106 Two 24W T5HO Lamps and Four 54 Watt T5HO 111 120 92 111 85 levels* Lamps,86 footcandle 101 108 101 Two 17W T8 Lamps and Four 54 Watt T5HO 88 82 levels* Lamps,80 footcandle 106 110 104 Two 24W T5HO Lamps and Four 54 Watt T5HO 92 85 levels* Lamps,86 footcandle Two 17W T8 Lamps and Four 54 Watt T5HO Lamps, footcandle levels* Two 24W T5HO Lamps and Four 54 Watt T5HO Lamps, footcandle levels* 5 ¾" (146mm) 6" (152mm) Ambient light Indirect illumination from either two 17W T8 or two 24 watt T5HO two foot lamps. • No direct glare to patient. • No direct glare to patient's visitor. • Low level of illumination comfortable for visitors or viewing television. Examination light Excellent color rendition given by four 54 watt T5HO lamps. • Wired for tandem switching. Ambient and examination light Optional 3 watt LED night light Only available in the Individual or Satellite luminaire. Suffix: NL. *Footcandle levels based on an opposing pair of MD*A luminaries. Comprehensive lighting catalog 7th Edition 4.143 Linear recessed and surface lighting – Specification MD*4 2' x 2' Recessed 36 cell with prismatic overlay examination luminaire MDS2G36PS4FT120SB Initial Footcandles on Bed CL 1 Fixture 5" (127mm) Features 24" (610mm) • 2 units provide 123 average footcandles on patients bed when installed over each end of bed. • Utilizes 2-2 lamp electronic ballast. • Utilizes 4-40 watt Biax type lamps with excellent color rendition (82 CRI). • 3 1/2" x 3 1/2" cell size. Candlepower Curve Reference data Efficiency 55.9% Spacing ratio 1.3 Electronic ballast 60˚ 1800 Input watts (120V) 132.0W Luminaire Eff. (LER) 31.3 3600 • Door jamb with integral positive light stop. 30˚ • Spring-loaded latches. 2 Fixture CL 12" WALL 12" 12" 52.5 54.8 52.7 106 111 107 63.9 66.8 64.1 119 125 120 74.5 78.0 74.7 128 134 129 77.9 81.6 78.1 133 139 133 75.6 79.1 75.8 132 138 133 68.6 71.8 68.8 123 129 123 57.6 60.3 57.9 109 114 110 3" 6" 12" Ordering information • Integral earthquake clip. Options & accessories 12" Type page 4.130 Ballast: Electronic 120 volt standard. For 277 volt, change 120 to 277 (e.g. MDS2G36PS4FT277SB). Fusing: Suffix: A (Internal fast-blow fusing). Suffix: C (Internal slow-blow fusing). Radio interference filter: Suffix: R. 120 or 277 volt at 50 or 60Hz. One per fixture standard. Electrical/wiring options: For special wiring, fusing, electronic dimming ballasts, consult factory. Cells MD*4 2x2 Recessed Examination Light Example Examination light shielding Slot-T or Concealed-T 36 Low iridescence specular louver MDS2G36PS4FT120SB w/prismatic overlay MDS2T36PS4FT120SB 36 Low iridescence semi-specular louver w/prismatic overlay MDS2T36LS4FT120SB MDS2G36PS4FT Examination Light Direct/indirect recessed Note: For concealed spline, plaster or drywall ceiling, use “G” type fixtures with either: S2X2F KIT, or Drywall kit, FK92X2. T-Grid MDS2G36LS4FT120SB 120 SB Voltage 120 = 120V 277 = 277V A Ballast See page 4.144 Options See page 4.144 and page 4.130 OBL series Over-bed, wall mounted luminaire OBL Over-bed light Features Switching • For nursing homes, hospitals and other health care facilities. • Separate lamp compartments for controlled uplight and downlight. • Cold rolled steel body with die-cast aluminum ends. • Concealed pull-action spring-loaded latches to retain lens. • Optional oak fascia insert. • Optional low voltage electronic sequential switch for push button control of up/down lighting. UL 544 listed. Includes phone jack type receptacle. page 4.216 Ballast: Specify voltage (120, 277 or UNV) and type and add as suffix, e.g. 277SO. Ballast type <10THD <20THD HI Philips Lightolier 3-6' reading plane 0 PS Lamp Configuration 2 Up/1 Down 2 Up/2 Down 1 Up/1 Down Example Size Lamp qty –type Catalog no. 48" OBL332 Over-Bed Wall Mounted Direct/indirect recessed 500 OBL332 OBL432 OBL232 3-T8 4-T8 2-T8 120 SO Voltage 120 = 120V 277 = 277V Ballast See page 4.144 60˚ 30˚ R Options See page 4.144 and page 4.216 Optional fascia insert: Oak—to order substitute K for L in Catalog no. (e.g. OBL332 to OBK332). Radio interference filter: Suffix: R. 120 or 277 volt at 50 or 60Hz. Momentary button cordset: Traditional “Winged” Pendant Design ESD protection to 15000 volts. Heavy duty 7" cable. Consult factory. Electronic (low voltage) sequential switch: Switch factory mounted in fixture for Up and Down Light Operation from pillow switch, UL544 listed. Includes phone jack type receptacle. Consult factory. (120V or 277V). Nite light: Consult factory. 4.144 500 Ordering information • Flat white fascia standard. T8 150˚ 120˚ 50 FC reading plane (60˚ from horizontal) Pull Switch 5 916" (141mm) • .125 thick DR acrylic linear prismatic refractor. (impact resistant). 1000 side view 6' • Four-way pull switch, standard (120 volt only). Options & accessories 3' 4 Lamps = 1, 2, 3, 4 3 Lamps = 1, 2, 4 2 Lamps = 2, 4 6 116" (154mm) Candlepower Curve Reading Position For complete specification information visit www.lightolier.com Specification – Linear recessed and surface lighting SUS 432/632 Over-bed, wall mounted luminaire SUS2GFSMA632UNVH6 5" (127mm) Features 24" (610mm) • Asymmetric/symmetric distribution provides:Supplemental illumination to operating tables. Ordering information Lamp Exposed qty –type T-Grid 6-T8 • Minimizes contrast between surgical and surrounding areas. Flanged for dry or plaster • Meets government specification for Radio Frequency Interference (RFI), MIL-STD 461-A, MIL-STD 463. SUS2GFSMA632 SUS2FFSMA632 • One radio suppressor per fixture (standard). • High efficiency 60.9% (6 light), 61.2% (4 light). One-piece housing The footcandle readings Black housing exterior of a typical 8' x 12' patfor cooler ballast tern layout of 8, 6 lamp operating temperature units, illustrates that the asymmetric distribution Black striped interior adds 35% more light to perimeter of body the operating area (room eliminates light leak Symmetrical distribution size 12' x 16' x 9' ceiling). Example SUS2GFSMA632 SUS 632 Surgical Perimeter Static Luminaire UNV Candlepower Curve Fully gasketed lens frame Hemmed over side-rails for safe handling Asymmetrical distribution H6 A Voltage Ballast 120 = 120V See page 4.145 277 = 277V UNV= 120-277V • Built-in earthquake clips. • Flat full-size steel lens frame is gasketed. 2400 60˚ 3400 4400 Options See page 4.145 and page 4.130 • Hemmed over side rails for safety. Options & accessories 30˚ page 4.130 Ballast: Specify voltage (120, 277 or UNV) and type and add as suffix, e.g. 277SO. Ballast type <10THD <20THD 2 - 2 Lamp Elec. T8 SO* HI* 3 - 2 Lamp Elec. T8 SO* HI* 1 - 4 Lamp Elec. T8 O4* H4* 2 - 3 Lamp Elec. T8 O6* H6* LOL Dimming T8 PS 5" (127mm) * Instant start Standard. Continuous row installation: For “F” type fixtures, half-width flanges are required between fixtures. Catalog no. 2FC Trim (each joint). 24" (610mm) Ordering information 4-T8 • 2 1/4" lamp to integral light stop for easy lamp removal. • Black housing exterior for cooler ballast operating temperature. SUS2GFSMA432UNVH4 Lamp Exposed qty –type T-Grid • One-piece housing. Plaster frames: “F” type fixtures do not include plaster frames. For individual or continuous mounting, specify PF24 universal frame per fixture. Flanged for dry or plaster SUS2GFSMA432 SUS2FFSMA432 Electrical/wiring: Options consult factory. Seismic hold-down clips: For "G" type troffers. Suffix: 4HD (for NYC only). The footcandle readings of a typical 8' x 12' pattern layout of 8, 4 lamp units, illustrates that the asymmetric distribution adds 35% more light to the operating area (room size 12' x 16' x 9' ceiling). Example Black housing exterior for cooler ballast operating temperature Black striped interior perimeter of body eliminates light leak SUS2GFSMA432 SUS 432 Surgical Perimeter Static Luminaire One-piece housing Hemmed over side-rails for safe handling Symmetrical distribution UNV Candlepower Curve Fully gasketed lens frame Asymmetrical distribution H4 Voltage Ballast 120 = 120V See page 4.145 277 = 277V UNV= 120-277V A 1200 60˚ Fusing: Suffix: A (Internal fast-blow fusing). Suffix: C (Internal slow-blow fusing). Radio interference filter: Suffix: R. If one per ballast is required. 120 or 277 volt at 50 or 60Hz. Note: Only one radio interference filter (RF) for fixture if 3 ballasts are used. 2200 3200 30˚ Options See page 4.145 and page 4.130 Built-in Earthquake Clip before installation Earthquake Clip installed (lay-in grid) Comprehensive lighting catalog 7th Edition 4.145 Linear recessed and surface lighting Architectural & surface utility Surface mounted luminaires are most often used in situations where it is not feasible to install recessed lighting: where there is no suspended ceiling, where there are obstructions above the ceiling, or where it is costly and troublesome to penetrate but surfacemounted luminaires are also extensively used because they serve as elements of distinctive style, providing an identity or signature; they add character to a space. Because a surface mounted fluorescent is subject to closer visual scrutiny than a recessed, standards of detailing craftsmanship are necessarily higher. The high quality of Philips Lightolier’s production is seen in this product offering. 4.146 Philips Lightolier For complete specification information visit www.lightolier.com Linear recessed and surface lighting Contents Stairwell > 4.148 Celebrity > 4.150 LWBU and LSW > 4.160 Deepcel Surface > 4.162 Belmont > 4.153 Prismalyte Surface > 4.163 Dorm Lyte > 4.158 Vision Smart Surface > 4.164 Dominaire Surface > 4.159 SLB > 4.165 Comprehensive lighting catalog 7th Edition 4.147 Linear recessed and surface lighting – Specification Philips Lightolier stairwell luminaire Wall/ceiling mounted fluorescent Prismatic lens option Conserving energy while maintaining safety. Stairwell lighting typically operates continuously at full output despite very low, intermittent use. The solution to this unique application is bi-level lighting which maintains minimum illumination requirements when the stairwells are empty, thereby maximizing energy savings. Bi-level lighting incorporates a sensor integrated into the fixture that dims the lighting down to minimum standards, when no one is present. When the fixture detects someone in the area, the lighting is restored to full brightness. This can result in 50 to 80 percent energy savings per fixture. The Philips Lightolier stairwell luminaire incorporates an internal motion sensor and a bi-level ballast. It provides a standby low-light level, and upon detection of motion in a space, immediately increases the lighting to full brightness. After occupancy is no longer detected, the fixture reverts back to the low, standby level. The automatic bi-level lighting control saves energy and ensures full light output when the space is occupied. The Philips Lightolier stairwell luminaire can be mounted on the wall or installed on a ceiling and is available in one or two lamp T8 and two lamp T5 linear fluorescent. Philips Lightolier stairwell luminaire Ideal for Stairwells, restrooms, laundry rooms and other areas where maximum light levels are not required on a constant basis. Lens options • Unique composite, 1/8" thick DR (impact resistant) acrylic lens with a white opaque center and linear prisms to spread up/down light. • Classic 1/8" thick linear prismatic virgin acrylic lens that is low in brightness • A Linear prismatic lens of 50% DR (impact resistant) and 50% standard acrylic with a nominal thickness of 1/8" that will withstand 70 foot-pounds of impact without breaking. Ultrasonic Occupancy Sensor Sensor options Tamper proof option • Ultrasonic technology (40Khz) Ultrasonic detection operates by transmitting sound waves throughout an area and measuring the speed at which they return. Infrared Occupancy Sensor • Adjustable time delay from 30 seconds to 30 minutes. • Fixed sensitivity optimized for FS-LxW lens coverages. • RoHS compliant. • Light level daylighting feature from 10-120 fc. Secondary endcaps, secured with Holt head screws, can be added to the luminaire for tamper proofing SF4C232UNVV2-US, two 32 watt T8 lamps, bi-level dimming ballast and integrated Ultrasonic sensor Example catalog SF4C232UNVV2-OC, two 32 watt T8 lamps, bi-level dimming ballast and integrated Infrared sensor For complete listing of available fixtures and specification sheets search Stairwell at www.lightolier.com 4.148 Philips Lightolier For complete specification information visit www.lightolier.com Specification – Linear recessed and surface lighting Philips Lightolier stairwell luminaire Lightolier Stairwell Luminaire Recessed and Surface lighting Wall/ceiling mounted fluorescent Wall/Ceiling Mounted Fluorescent Ordering Information T5 or T5HO SF 4 C 2 Lighting in motion. Stairwell: Wall Mounted Fluorescent Fixture Length: 4=48" (Nominal 48") 28 Lens Type: Lamp C =White Composite Quantity: Acrylic Lens 2=2 Lamp R = Linear Prismatic Virgin Acrylic Lens V = Vandal Proof ~ A High impact, 50% DR Acrylic Linear Prismatic Lens with Additional Secondary Vandal proof end-caps secured with holt head screws. (Factory Installed Only) UNV Lamp Type: (By Others) 28=T5 28W 54=T5HO 54W (Nominal 48") Voltage‡: 120, 277 or UNV = 120-277 VY Fast facts - US Options: Optional Ballast Type: <10THD Sensor Type: Options: • Integrated occupancy sensor, ultrasonic or infrared motion 2 Lamp 28W Elec. T5 VY (.95BF) US=UltraSonic DL=Optional GSA Emergency Pack Fusing: (Consult Factory A=Internal 100% / 50% Bi-level OC=Infrared ballast low level • Available in T8, T5 and T5HO lamping controller. for applicable fast blowing 2 Lamp 28W Elec. T5 PG †† Three unique lens options code) C=Internal 2• Lamp 54W Elec. T5HO NQ (.80BF) Note: DLAct option slow blowing 100% / 50% • Only 3 ⅞"Bi-level deep, meeting the Americans with Disabilities requires the use of 2 Lamp 54W Elec. T5HO PG †† requirements for wall mounted fixtures a 0-10 volt dimming • Additional available for GSA requirements (consult factory) ballast. Dimming 0-10dimmer Volt 2 Lamp 28W Elec. T5 EQ‡ Note: Consult local code 2 Lamp 54W Elec. T5HO MW‡ authority for applications where Stairwell luminaire will ‡ Specific 120 or 277 voltage must be be used as emergency lighting. specified with use of a 0-10 volt dimming ballast. ††Program Rapid Start (UNV only) Recessed and Surface lighting Lightolier Stairwell Luminaire Wall/Ceiling Mounted Fluorescent Note: UNV PG combination will result in lamps controlled by occupancy sensor in a ON or OFF capacity. Ordering Information T5 or T5HO SF Stairwell: Wall Mounted Fluorescent 4 Fixture Length: 4=48" (Nominal 48") C 2 28 Lens Type: Lamp C =White Composite Quantity: Acrylic Lens 2=2 Lamp R = Linear Prismatic Virgin Acrylic Lens V = Vandal Proof ~ A High impact, 50% DR Acrylic Linear Prismatic Lens with Additional Secondary Vandal proof end-caps secured with holt head screws. (Factory Installed Only) Lighting in motion. UNV Lamp Type: (By Others) 28=T5 28W 54=T5HO 54W (Nominal 48") Voltage‡: 120, 277 or UNV = 120-277 VY - US –– –– – Sensor Type: Options: Options: Optional Ballast Type: <10THD 2 Lamp 28W Elec. T5 VY (.95BF) US=UltraSonic DL=Optional GSA Emergency Pack Fusing: OC=Infrared ballast low level (Consult Factory A=Internal 100% / 50% Bi-level controller. for applicable fast blowing 2 Lamp 28W Elec. T5 PG †† Fast code) C=Internal 2 Lamp 54WFacts Elec. T5HO NQ (.80BF) Note: DL option slow blowing 100%• /Integrated 50% Bi-level occupancy sensor, Ultrasonic or Infrared motion requires the use of 2 Lamp 54W Elec. T5HO PG †† • Available in T8, T5 and T5HO lamping a 0-10 volt dimming ballast. Dimming 0-10 Volt lens options • Three unique 2 Lamp 28W Elec. T5 EQ‡ • Only 3 ⅞" deep, meeting the Americans with Disabilities Act Note: Consult local code 2 Lamp 54W Elec. T5HO MW‡ authority for applications requirements for wall mounted fixtures where Stairwell luminaire will ‡ Specific 120 or 277 voltage must be • Additional proprietary dimmer available for GSA requirements be used as emergency lighting. specified with use of a 0-10 volt dimming ballast. (Consult Factory) ††Program Rapid Start (UNV only) Note: UNV PG combination will result in lamps controlled by occupancy sensor in a ON or OFF capacity. Ordering Information T8 SF 4 C Lighting in motion. Stairwell: Wall Mounted Fluorescent Fixture Length: 2=24" 4=48" Lens Type: C =White Composite Acrylic Lens R = Linear Prismatic Virgin Acrylic Lens V = Vandal Proof ~ A High impact, 50% DR Acrylic Linear Prismatic Lens with Additional Secondary Vandal proof end-caps secured with holt head screws. (Factory Installed Only) 2 Lamp Quantity: 1=1 Lamp 2=2 Lamps 32 Lamp Type: (By Others) 17=17W T8 (Nominal 24") 32=32W T8 (Nominal 48") UNV Voltage‡: 120, 277 or UNV=120-277 UN2 = 2, one lamp universal voltage ballasts (SF4 ONLY) V2 - US –– Ballast Type:Facts <10THD Sensor Type: Options: Fast 1 or 2 Lamp 17W or 32W Elec. T8 V2 US=UltraSonic DL=Optional GSA • Integrated occupancy sensor, Ultrasonic or Infrared motion 100% / 50% Bi-level OC=Infrared ballast low level 1 or 2• Lamp 17W or Elec. T8 T5HO P2* lamping controller. Available in 32W T8, T5 and –– Options: Emergency Pack (Consult Factory for applicable code) – Optional Fusing: A=Internal fast blowing C=Internal slow blowing • Three unique Dimming 0-10 Volt lens options Note: DL option 1 or 2• Lamp 32W meeting Elec. T8 the M7‡Americans with requires the use of Only17W 3 ⅞"ordeep, Disabilities Act a 0-10 volt dimming requirements for wall mounted fixtures ‡ Specific 120 or 277 voltage must be ballast. specified with use of proprietary a 0-10 volt dimming • Additional dimmer available for GSA requirements Note: Consult local code ballast. (Consult Factory) authority for applications *Program Start Standard where Stairwell luminaire will be used as emergency lighting. Note: UN2 P2 combination will result in one lamp always ON with second lamp controlled by occupancy sensor. UNV P2 combination will result in lamp/lamps controlled by occupancy sensor in a ON or OFF capacity. Note: Stairwell luminaire also available in LED Ordering Information T8 SF 4 C 2 32 UNV V2 - Comprehensive lighting catalog 7th Edition US 4.149 Linear recessed and surface lighting – Specification Celebrity (CWBU) Universal Wall mounted downlight luminaire The ultimate in glare-free architectural lighting. A classic rectilinear wall fixture with a jewel-like diamond faceted injection molded refractor that mirrors out brightness at critical viewing angles. Ideal for nursing homes when used as a bed-light in the uplight/ downlight configuration. It is also excellent when used over mirrors, in corridors and for Features • Universal luminaire that has uplight/downlight or downlight capabilities on the same fixture. • Low brightness controlled downlighting and uplighting/ downlighting. task lighting in the downlight only configuration. CWBU232UNVHI • Injection-molded one-piece virgin acrylic downlight refractor (1 side, 2 ends and face). 2 Lamp Downlight • Catadioptric side and end wall design (downlight). Efficiency 63.0% Spacing ratio 1.2 3 116" (78mm) • Slim 3 1/16" depth. • Nominal 2' and 4' lengths. • 63% efficient T8 lamps downlight. Candlepower Curve Reference data Uplight Lens Cover 90˚ Electronic ballast Input watts (120V) 62.0W 7 ⅝" (194mm) 500 60˚ • 67.1% efficient T8 lamps uplight/downlight. • Invisible steel latches align refractor to housing. • Individual or continuous rows. • For over mirror, over bed, corridor, stairwell and bulletin board applications. Options & accessories Ordering information Type Size Downlight 7 ⅝" x 25 ½" 7 ⅝" x 49 ½" 1000 Lamp qty –type 2-T8 Catalog no. CWBU217 CWBU232 1500 page 4.216 Ballast: Specify voltage (120, 277 or UNV) and type and add as suffix, e.g. UNVHI. Example Electronic T8 HI*, P2** SO* LOL T8 Dimming – PS * Instant start ** Program start CWBU232 CWBU Wall Mounted Downlight Luminaire Ballast type <10THD <20THD UNV HI A Voltage Ballast 120 = 120V See page 4.150 277 = 277V UNV= 120-277V Options See page 4.150 and page 4.216 (Elec. T8 Ballast only) CWBU132UNVHI Electrical/wiring options: For special wiring, fusing, electronic dimming ballasts or emergency pack, consult factory. 1 Lamp Downlight Efficiency 68.4% Spacing ratio 1.2 3 1163" 116" (78mm) (78mm) Fusing: Suffix: A (Internal fast-blow fusing). Suffix: C (Internal slow-blow fusing). Input watts (120V) 30.0W 7 ⅝"7 (194mm) ⅝" (194mm) 500 60˚ Type Size Downlight 7 ⅝" x 25 ½" 7 ⅝" x 49 ½" Example Philips Lightolier 90˚ Electronic ballast Ordering information 4.150 Candlepower Curve Reference data Uplight Lens Cover Uplight Lens Cover Radio interference filter: 120 or 277 volt, 50 or 60 Hz. One per fixture. Suffix: R. Uplight lens cover for downlignt only 30˚ CWBU132 CWBU Wall Mounted Downlight Luminaire 1000 Lamp qty –type 1-T8 UNV Catalog no. CWBU117 CWBU132 HI Voltage Ballast 120 = 120V See page 4.150 277 = 277V UNV= 120-277V 1500 30˚ A Options See page 4.150 and page 4.216 (Elec. T8 Ballast only) For complete specification information visit www.lightolier.com Specification – Linear recessed and surface lighting Celebrity (CWBU) Universal Wall mounted uplight/downlight luminaire The ultimate in glare-free architectural lighting. A classic rectilinear wall fixture with a jewel-like diamond faceted injection molded refractor that mirrors out brightness at critical viewing angles. Ideal for nursing homes when used as a bed-light in the uplight/ downlight configuration. It is also excellent when used over mirrors, in corridors and for Features task lighting in the downlight only configuration. • Universal luminaire that has uplight/downlight or downlight capabilities on the same fixture. CWBU232UNVHI 2 Lamp Uplight / Downlight Efficiency 67.1% Spacing ratio 1.3 3 116" (78mm) 90˚ 60˚ 45˚ Size Uplight / Downlight 7 ⅝" x 25 ½" 7 ⅝" x 49 ½" CWBU232 CWBU Wall Mounted Uplight/Downlight Luminaire Lamp qty –type HI 30˚ Options See page 4.151 and page 4.216 CWBU132UNVHI Candlepower Curve Reference data Efficiency 69.8% Spacing ratio 1.3 500 90˚ Electronic ballast 60˚ Input watts (120V) 30.0W 7 ⅝"7 (194mm) ⅝" (194mm) Electronic T8 HI*, P2** SO* LOL T8 Dimming – PS * Instant start ** Program start Electrical/wiring options: For special wiring, fusing, electronic dimming ballasts or emergency pack, consult factory. Radio interference filter: 120 or 277 volt, 50 or 60 Hz. One per fixture. Suffix: R. Fusing: Suffix: A (Internal fast-blow fusing). Suffix: C (Internal slow-blow fusing). 45˚ Type Size Uplight /Downlight 7 ⅝" x 25 ½" 7 ⅝" x 49 ½" CWBU Wall Mounted Uplight/Downlight Luminaire page 4.216 500 Ordering information CWBU132 • Individual or continuous rows. Ballast type <10THD <20THD 1 Lamp Uplight / Downlight 3 1163" 116" (78mm) (78mm) • Invisible steel latches align refractor to housing. Options & accessories (Elec. T8 Ballast only) Uplight Lens Cover Uplight Lens Cover • 63% efficient T8 lamps downlight. Ballast: Specify voltage (120, 277 or UNV) and type and add as suffix, e.g. UNVHI. A Voltage Ballast 120 = 120V See page 4.151 277 = 277V UNV= 120-277V • Nominal 2' and 4' lengths. • For over mirror, over bed, corridor, stairwell and bulletin board applications. 1000 CWBU217 CWBU232 2-T8 UNV Catalog no. • Catadioptric side and end wall design (downlight). • 67.1% efficient T8 lamps uplight/downlight. 500 Type • Injection-molded one-piece virgin acrylic downlight refractor (1 side, 2 ends and face). • Slim 3 1/16" depth. Input watts (120V) 62.0W Ordering information Example 500 Electronic ballast 7 ⅝" (194mm) Example Candlepower Curve Reference data Uplight Lens Cover • Low brightness controlled downlighting and uplighting/ downlighting. Lamp qty –type 1000 CWBU117 CWBU132 1-T8 UNV Catalog no. HI Voltage Ballast 120 = 120V See page 4.151 277 = 277V UNV= 120-277V 30˚ A Options See page 4.151 and page 4.216 Uplight lens cover removed for uplight/ downlignt (Elec. T8 Ballast only) Comprehensive lighting catalog 7th Edition 4.151 Linear recessed and surface lighting – Specification Celebrity Surface Surface Features CBS232UNVHI • .187 lens thickness. Efficiency 78.2% Spacing ratio 1.4 3 ¼" (83mm) • Catadioptric side/end wall design, for low brightness. • Tight aligning refractor fit. Electronic ballast 12" (305mm) • Invisible spring steel latches. 700 60˚ Input watts (120V) 59.1W Luminaire Eff (LER) 66.2 • Easy ballast accessibility. 1400 • Rigid, reinforced housing. • Individual or continuous row mounting. Options & accessories Candlepower Curve Reference data • Five side injection molded refractor with square base, conical prisms (absolutely no sag). page 4.216 Ballast: Specify voltage (120, 277 or UNV) and type and add as suffix, e.g. UNVHI. Ballast type <10THD <20THD 1 - 2 Lamp Electronic T8 HI*, P2** SO* LOL T8 Dimming – PS * Instant start ** Program start Electrical/wiring options: For special wiring, fusing, electronic dimming ballasts or emergency pack, consult factory. Ordering information Type Size Surface Prismatic 12" x 49 9⁄16" Example CBS232 Celebrity Surface Wrap Luminaire Lamp qty –type 2-T8 UNV Catalog no. 2100 CBS232 HI Voltage Ballast 120 = 120V See page 4.152 277 = 277V UNV= 120-277V 30˚ A Options See page 4.152 and page 4.216 (Elec. T8 Ballast only) Specification Surface Lens CBS Unit Matches CWBU Celebrity Wall Unit Not recommended for stem mounting. Fusing: Suffix: A (Internal fast-blow fusing). Suffix: C (Internal slow-blow fusing). Sturdy steel chassis Four sided injection molding Photograph illustrates action of Celebrity lens enclosure. Catadioptric prisms “mirror” out glare, refract light beams into u seful areas. 4.152 Philips Lightolier For complete specification information visit www.lightolier.com Specification – Linear recessed and surface lighting Belmont Spill Frame 2' x 4' 2X4 BELMONT SF (4) F32 T8 2X4 BELMONT 2X4 BELMONT SF (4) F32SFT8(2) F32 T8 2X4 BELMONT SF (2) F32 T8 2X2 BELMONT SF (4) F17 T8 2X2 BELMONT SF (4) F17SFT8(2) F40 TT5 2X2 BELMONT 2X2 BELMONT SF (2) F40 TT5 Architectural surface luminaire Belmont Spill Frame features an extruded aluminum frame with a unique uninterrupted spill of light on all four sides with a soft-white, impact resistant acrylic lens. The step back chassis creates a floating frame effect with an apparent depth of only 1½ inches. The frame can be opened and/or hinged from either side without tools for easy lamp replacement. 1 ½" 1 ½" (38mm) (38mm) Belmont Spill Frame 15 ½" 15 ½" (394mm) (394mm) 1 ½" 1 ½" (38mm) (38mm) The intriguing appearance and ease of maintenance make Belmont Spill 3 ¾" Frame the ideal choice for surface 1 ½" 3 ¾" (95mm) 1 ½" (38mm) mounted lighting applications for (95mm) (38mm) cafeterias, corridors, small offices, kitchens or family rooms. 15 ½" 15 ½" (394mm) (394mm) 3 ¾" 3 ¾" (95mm) (95mm) Features • Excellent for lighting cafeterias, small offices, corridors, 15 ½" kitchens and family rooms. 15 ½" (394mm) (394mm) • Unique rectangular double frame creates uninterrupted spill of light from all four sides. 3 ¾" • Extruded aluminum frame with mitered corners.3 ¾" (95mm) • 1/8” thick white acrylic lens containing 25% DR.(95mm) • Only 3-3/4” total depth. • Step back housing for an apparent depth of 1-1/2”. 44 116" 5 316" 44 116"(1119mm) 3 (132mm) 5 16" (1119mm) 39 ⅝" (132mm) 39 ⅝" (1006mm) (1006mm) 18" • Lens opens and hinges from either side. (457mm) 5" (127mm) 18" 5" (127mm) (457mm)on T-grid ceilings. • Zip-clip ⅞" K.O. Within flush mount 932" Mounting ⅞" KO 1 ⅞" K.O. ⅞" K.O. Within 7/8” K.O.15for ceiling. ½" flush mount to932T-grid ⅞" KO 1 ⅞" K.O. • Off-center ⅞" K.O. " MountingHole 15 ½" (394mm) Hole ⅞" K.O. 15 ½" (394mm) ⅞" K.O. 15 ½" (394mm) 15 ½" ⅞" K.O. 1 116" (27mm) (394mm) ⅞" KO3 ¾" 15 ½" (394mm) 1 ½" 1 116" (27mm) 916" Mounting 932" Mounting 3132" (394mm) 1 ½" 3⅞" ¾"KO (38mm) (95mm) 916" Mounting Hole 932" Mounting Hole 3132" (25mm) (38mm) (95mm) Hole Hole 7 1132" (25mm) 9 5" 32" Mounting ⅞" K.O. Within 7 1132" (187mm) 3" (76mm) 20" 932" Mounting Hole 1 ⅞" K.O. 5" (127mm) ⅞" K.O. Within (187mm) 50" 3" (76mm) 20" (508mm) (127mm) Hole 1 ⅞" K.O. (1270mm) 50" (508mm) 26" (1270mm) 26" (660mm) Ordering information (660mm) Note: Chassis and Lamps Electronic shielding are packed Type Finish Shielding Chassis ballast qty –type in separate cartons. 2X4 BELMONT When ordering, enter SF (4) F32 T8 1X4 BELMONT SF (2) F32 T8 Belmont 2 - 2 Lamp Black BESF2X4 BE2B432UNVHI 2X4 BELMONT 2X4 BELMONT SF (4) F32 T8 SF (2) F32 T8 as separate line items. 1X4 BELMONT SF (2) F32 T8 Spill Frame Architectural Surface Luminaire 2 - 2 Lamp 1 - 4 Lamp 1 - 4 Lamp 4-T8 2 " (75mm) 2 3132" (75mm) ⅞" KO ⅞" KO 31 32 White Black White BESF2X4 BESF2X4 BESF2X4 BE2W432UNVHI2X4 BELMONT SF (2) F32 T8 BE2B432UNVH4 BE2W432UNVH4 Belmont Spill Frame 1' x 4' Architectural surface luminaire Belmont Spill Frame 10 ½" (267mm) 1 ½" (38mm) 10 ½" (267mm) 1 ½" (38mm) 15 ½" (394mm) 3 ¾" (95mm) 5 316"44 116" (132mm) (1119mm) 39 ⅝" (1006mm) 3 ¾" (95mm) 44 116" (1119mm) 39 ⅝" (1006mm) ⅞" K.O. Ordering information Type Belmont Spill Frame Architectural Surface Luminaire Lamps qty –type 2-T8 1 ½" (38mm) 1 ½" (38mm) 2 3132" (75mm) 5 316" 2 3132" (75mm) (132mm) ⅞" K.O. ⅞" K.O. ⅞" K.O. ⅞" K.O. 10 ½" ⅞" K.O. 10 ½" 3132" (267mm) 932" Mounting (267mm) 3132" (25mm) 932" Mounting Hole 932" Mounting (25mm) 5" ⅞" K.O. Within Hole Hole Mounting ⅞" K.O. Within 1 ⅞" K.O. 5" 50"932" (127mm) 1 ⅞" K.O. (1270mm)Hole 50" (127mm) (1270mm) Electronic Finish Shielding ballast 1 - 2 Lamp Black White BESF1X4 BESF1X4 Chassis BE1B232UNVHI BE1W232UNVHI 5 316" (132mm) ⅞" K.O. ⅞" K.O. 15 ½" (394mm) 3 ¾" (95mm) 3 ¾" (95mm) 5 316"44 116" (132mm) (1119mm) 39 ⅝" (1006mm) 44 116" (1119mm) 39 ⅝" (1006mm) ⅞" KO 2 3132" (75mm) ⅞" KO 2 3132" (75mm) ⅞" KO 15 ½" (394mm 15 ½" (394mm)3132" 3132" (25mm) (25mm) 932" Mounting 5" ⅞" K.O. Within Hole Mounting ⅞" K.O. Within 1 ⅞" K.O. 5" 50"932" (127mm) (127mm) 1 ⅞" K.O. (1270mm)Hole 50" (1270mm) " Mounting 932" Mounting Hole Hole 9 32 Note: Chassis and shielding are packed in separate cartons. When ordering, enter as separate line items. ⅞" KO Comprehensive lighting catalog 7th Edition 4.153 ½" 4mm) ½" mm) 15 ½" (394mm) Linear 3recessed and surface lighting – Specification ¾" (95mm) 3 ¾" (95mm) Architectural surface luminaire Belmont Spill Frame features an extruded aluminum frame with a unique uninterrupted spill of light on all four sides with a soft-white, impact resistant acrylic lens. The step back chassis creates a floating frame effect with an apparent depth of only 1½ inches. The frame can be opened and/or hinged from either side without tools for easy lamp replacement. 2X2 BELMONT SF (4) F17 T8 2X2 BELMONT SF (4) F17 T8 2X2 BELMONT SF (2) F40 TT5 2X2 BELMONT SF (2) F40 TT5 Features Belmont Spill Frame15 ½" • Excellent for lighting cafeterias, small offices, corridors, kitchens and family rooms. • Unique rectangular double frame creates uninterrupted spill of light from all four sides. • Extruded aluminum frame with mitered corners. • 1/8” thick white acrylic lens containing 25% DR. (394mm) 15 ½" (394mm) 1 ½" (38mm) 1 ½" (38mm) 3 ¾" (95mm) 3 ¾" (95mm) • Only 3-3/4” total depth. 15 ½" (394mm) 15 ½" (394mm) • Step back housing for an apparent depth of 1-1/2”. • Lens opens and hinges from either side. ¾" • Zip-clip flush 3mount 3on ¾" T-grid ceilings. (95mm) 1 ½" (38mm) 1 ½" (38mm) ⅞" KO ⅞" KO 932" Mounting mm) 5" Hole932" Mounting (127mm) Hole 2 3132" (75mm) 2 3132" (75mm) ⅞" KO ⅞" KO 15 ½" (394mm) 15 ½" (394mm) 3132" (25mm) 3132" (25mm) ⅞" K.O. Within 1 ⅞" K.O.⅞" K.O. Within 1 ⅞" K.O. ⅞" K.O. ⅞" K.O. 1 116" (27mm) 1 116" (27mm) 916" Mounting Hole916" Mounting Hole m) The intriguing appearance and ease of maintenance make Belmont Spill Frame the ideal choice for surface mounted lighting applications for cafeterias, corridors, small offices, kitchens or family rooms. 3 ¾" (95mm) 3 ¾" (95mm) (95mm) • Off-center 7/8” K.O. for flush mount to T-grid ceiling. )44 116" 1119mm) m)39 ⅝" 1006mm) Belmont Spill Frame 2' x 2' 18" (457mm) 18" (457mm) 5" (127mm) 5" (127mm) " Mounting Hole932" Mounting Hole 15 ½" (394mm) 15 ½" (394mm) ⅞" KO ⅞" KO 9 32 7 1132" 7 1132" 3" (76mm) 20" (187mm) (187mm) 3" (76mm) (508mm) 20" 26" (508mm) (660mm) 26" (660mm) Ordering information Type Belmont Spill Frame Architectural Surface Lum. 4.154 Philips Lightolier Lamps qty –type 4-T8 4-T8 4-T8 4-T8 2-TT5 40W 2-TT5 40W Electronic Finish Shielding ballast 2 2 1 1 1 1 - 2 2 4 4 2 2 Lamp Lamp Lamp Lamp Lamp Lamp Black White Black White Black White BESF2X2 BESF2X2 BESF2X2 BESF2X2 BESF2X2 BESF2X2 Chassis BE2B417UNVHI BE2W417UNVHI BE2B417UNVH4 BE2W417UNVH4 BE2B2FTUNVIB BE2W2FTUNVIB Note: Chassis and shielding are packed in separate cartons. When ordering, enter as separate line items. For complete specification information visit www.lightolier.com Specification – Linear recessed and surface lighting Belmont I & ll 2' x 4' & 1' x 4' Linear fluorescent utility luminaire Ideally suited to circulation, utility, and workspaces, these shallow, sleek lightforms are available in the more efficient T8 Electronic lamp-ballast systems. Belmont I Application data for surface mounted Wrap-around acrylic diffuser with end caps attached. Complete Iuminaire consists of Lightshield and Chassis. Specify and order each item separately. Not suitable for row mounting. 3 ¾" (95mm) 3 ½" (89mm) 10 ¾" (273mm) Style Multiple Fixtures Single Fixture Lamp Fixture Spacing, O.C F.C.* 30' x 50' Room F.C.* 12 x 12' Room Belmont I 6' 8' 10' 78 28 28 15 96 61 42 22 16" (406mm) 50 ¼" (1276mm) 50 ¼" (1276mm) (2) 40W T12 (2) 32W T8: F.C. x 0.9 Belmont II 1x4 2x4 (4) 40W T12 Ordering information Type Size 1' x 4' 1' x 4' Belmont I Utility Luminaire 2' x 4' 2' x 4' 8' 10' 12' (4) 32W T8: F.C. x 0.9 Lamps qty –type Lightshield (Order separately) Electronic Wattage Finish Chassis ballast 2-T8 2-T8 32W UNV Black White BE1B232UNVHI 10324 BE1W232UNVHI 10324 4-T8 4-T8 32W UNV Black White BE2B432UNVHI 10328 BE2W432UNVHI 10328 For products that require 1-4 light ballast add suffix H4. Example: BE2B432UNVH4 Belmont ll Linear acrylic arc with no visible trim. Complete luminaire consists of Lightshield and Chassis. Specify and order each item separately. Not suitable for row mounting. 3 ⅞" (98mm) 10 ⅝" (270mm) 3 ⅞" (98mm) 15 ⅝" (397mm) 49 ½" (1257mm) 49 ½" (1257mm) 1x4 2x4 Ordering information Type Size 1' x 4' 1' x 4' Belmont II Utility Luminaire 2' x 4' 2' x 4' Lamps qty –type Lightshield (Order separately) Wattage Electronic Finish Chassis ballast 2-T8 2-T8 32W UNV Black White BE1B232UNVHI 10326 BE1W232UNVHI 10326 4-T8 4-T8 32W UNV Black White BE2B432UNVHI 10330 BE2W432UNVHI 10330 For products that require 1-4 light ballast add suffix H4. Example: BE2B432UNVH4 * Footcandle values of illumination are initial and average and are at a height of 30" above the floor. They are shown for rooms with ceiling heights ranging from 8' to 12'. Room finishes are typical: white ceiling (80% refl.). Light Walls (50% refl.) and dark floor (20% refl.). All units are: cULus listed, suitable for damp locations. Comprehensive lighting catalog 7th Edition 4.155 Linear recessed and surface lighting – Specification Belmont Cloud 2' x 4' & 1' x 4' Linear fluorescent utility luminaire Ideally suited to circulation, utility, and workspaces, these shallow, sleek lightforms are available in the more efficient T8 Electronic lamp-ballast systems. Belmont Cloud All units are: cULus listed, suitable for damp locations. Acrylic diffuser with softly contoured edges. Complete luminaire consists of Lightshield and Chassis. Specify and order each item separately. 4" (102mm) 13 ¾" (349mm) 4" (102mm) 17" (432mm) Not suitable for row mounting. 51 ½" (1308mm) 51 ½" (1308mm) 1x4 2x4 Ordering information Type Size 1' x 4' Belmont 1' x 4' Cloud Utility Luminaire 2' x 4' 2' x 4' Lamps qty –type Lightshield (Order separately) Wattage Electronic Finish Chassis ballast 2-T8 2-T8 32W UNV Black White BE1B232UNVHI 10325 BE1W232UNVHI 10325 4-T8 4-T8 32W UNV Black White BE2B432UNVHI 10327 BE2W432UNVHI 10327 For products that require 1-4 light ballast add suffix H4. Example: BE2B432UNVH4 4.156 Philips Lightolier For complete specification information visit www.lightolier.com Specification – Linear recessed and surface lighting Belmont 6" Cloud & Vanity Light Architectural surface Belmont 6" Cloud 24" (610mm) or 36" (914mm) 4" (102mm) 2' or 3' Channel Features 4 ⅛" (105mm) 6" (152mm) 4 ⅝" (117mm) • 6" white opal acrylic lens (vacuum formed). • Can be horizontally or vertically wall mounted. • Can be ceiling mounted. 4 ⅛" (105mm) • Efficiency 69.0%. • Lens secured to body with screws at ends. 26 ½" (673mm) 38 ½" (978mm) 48" 4" (102mm) 4' Channel K.O. • Quarter turn latch secures channel cover for easy wireway access. 6" (152mm) • Heavy duty channel of code gauge die formed steel. • Fully enclosed wiring. 6" (152mm) 4 ⅝" (117mm) • UL Listed snap-on end caps (body). • Green grounding screw installed in channel. Options & accessories 6 ⅜" (162mm) 2" Dia. K.O. with ⅞" Dia. ⅞" Dia. K.O. 50 ½" (1282mm) Ordering information Type Ballast type <10THD <20THD K.O. Electronic T8 HI – When ordering, enter as separate line items. Lamps qty –type Size 6" x 24" Belmont 6" x 36" 6" Cloud Utility Luminaire 6" x 48" 2-T8 Voltage Chassis Shielding SW2S217HPFUNVHI BCW6X24 UNV (120-277V) SW2S225HPFUNVHI BCW6X36 SW2S232HPFUNVHI BCW6X48 Note: Chassis and shielding are packed in separate cartons. Chassis and shielding shown are stock items. Vanity Light Features • Can be horizontally or vertically mounted. • 4 3/4" diameters opal white acrylic lens. 2" (51mm) 24" (610mm) 36" (914mm) 48" (1219mm) • Positive stainless steel lens retainers. 2 ½" (64mm) • Permanently installed milk white opaque diffuser ends with decorative trim. • Efficiency 76.6% (T8). 4" (102mm) 24" (610mm) 36" (914mm) 48" (1219mm) • UL Listed snap-on end caps (body). • Green grounding screw installed in channel. 4 ¾" (121mm) Ordering information Size 4 ¾" x 24" Vanity Light 4 ¾" x 36" Utility Luminaire 4 ¾" x 48" When ordering, enter as separate line items. Lamps qty –type 1-T8 • Heavy duty channel of code gauge die formed steel. • Fully enclosed wireway. ⅞" Dia. (22mm) 25 ½" (648mm) 37 ½" (953mm) 49 ½" (1257mm) Type • Quarter turn latch secures channel cover for easy wireway access. Voltage Chassis SN2S117HPFUNVHI UNV (120-277V) SN2S125HPFUNVHI SN2S132HPFUNVHI Shielding Options & accessories Ballast type <10THD <20THD Electronic T8 HI – VLW4X24 VLW4X36 VLW4X48 Note: Chassis and shielding are packed in separate cartons. Chassis and shielding shown are stock items. Comprehensive lighting catalog 7th Edition 4.157 Linear recessed and surface lighting – Specification Dorm Lyte Wall mounted fluorescent luminaire Dorm Lyte Features • For dorms, nursing homes, assisted living, health care facilities, or other over bed or wall mounted applications. • Up and downlight, 1 or 2 lamp. • Separate lamp compartments for controlled uplight and downlight for 2 lamp models. 1' 15 35 52 35 15 3' 15 25 31 35 15 • 1/8" thick DR acrylic lens. Unique co-extension. White opaque center. Frosted white front sections for subtle glow. Linear prisms to spread up/downlight. 5' 12 14 16 14 12 7' 9 10 10 10 9 • Only 3-7/8" deep, meets American With Disabilities Act for wall mounted fixtures. 9' 8 8 8 8 7 11' 7 7 7 7 7 1' 3' 5' 7' 9' • Concealed pull-action spring-loaded latches to retain lens. • 20 gauge cold rolled steel post painted baked white enamel end caps. Reading Position 3' Reference data Room Size: 12' x 10' x 8' Ceiling. • Nominal 4' length. Reflection: 80-50-20.80LLF • Four-way pull switch, (120 volt only) optional. • Optional low voltage electronic sequential switch for push button control of up/down lighting. UL 544 listed. Includes phone jack type receptacle. Options & accessories Reading Area: 35-40fc 35 to 40 fc reading plane (60° from horizontal) page 4.216 5' Ballast type <10THD <20THD Electronic T8 HI* SO* Electronic T5 P.S. (28W or 54W) PG – 3 ½' Reading Plane 1' 15 35 52 35 15 3' 15 25 31 35 15 5' 12 14 16 14 12 7' 9 10 10 10 9 9' 8 8 8 8 7 11' 7 7 7 7 7 1' 3' 5' 7' 9' * Instant start Reading Position Fusing: Suffix: A (Internal fast-blow fusing). Suffix: C (Internal slow-blow fusing). Independent Up/Down Light 2 T5 or T8 Lamps 6 ⅛" (155mm) 6 ⅛" (155mm) Type 3 ⅞" (98mm) 3 ⅞" (98mm) 6 ⅛" (156mm) 24 ¼" (616mm) 48 ½" (1232mm) 4.158 Philips Lightolier Size Up/Down Light 48" Independent 48" Up or Down Light Example 4 ¼" (108mm) 35 to 40 fc reading plane (60° from horizontal) Ordering information Up/Down Light 1 or 2 T5 or T8 Lamps DM4X232 Dorm Lyte Wall Mounted Fluorescent 3' Lamps qty –type Wattage Catalog number 1-T5 28W 1-T8 3 ½' 32W 1-T5HO Reading54W 2-T5 Plane 28W 2-T8 32W 2-T5HO 54W DM4X128 DM4X132 DM4X154 DM4X228 DM4X232 DM4X254 2-T5 2-T8 2-T5HO DM4R228 DM4R232 DM4R254 28W 32W 54W UNV HI Voltage Ballast 120 = 120V See page 4.158 277 = 277V UNV= 120-277V 5' A Options See page 4.158 and page 4.216 (Elec. T8 or T5 Ballast) For complete specification information visit www.lightolier.com Specification – Linear recessed and surface lighting Dominaire Surface Surface WA4A232UNVHI Candlepower Curve Reference data Features Efficiency 70.9% Spacing ratio 1.4 2 ⅝" (67mm) Electronic ballast 9" (229mm) • Step back housing for an apparent depth of 1 1/2". 600 60˚ Input watts (120V) 63.0W Luminaire Eff (LER) 56.5 • Luminous catadioptric end caps. • Two side shelf-leveling lens hinging. 1200 • 9" wide, 4' nominal lengths. Ordering information Type Size Prismatic Luminaire 9" x 49 9⁄16" Example WA4A232 Dominaire Surface Wrap Luminaire Lamp qty –type UNV • 14" wide, 4' nominal length. Catalog no. 1800 WA4A232 2-T8 HI 30˚ • Zip-clip flush mount on T-grid ceilings. • Off-center 7/8" K.O. for flush mount to T-grid ceiling. • Optional UL-listed low density mounting spacers. A Voltage Ballast 120 = 120V See page 4.159 277 = 277V UNV= 120-277V • Prismatic virgin acrylic lens. • Completely assembled with setup ends to lamp holders. Options See page 4.159 and page 4.216 Options & accessories (Elec. T8 Ballast only) Ballast type <10THD <20THD Electronic T8 Efficiency 70.1% Spacing ratio 1.3 Electronic ballast 14" (356mm) 1000 60˚ Input watts (120V) 84.4W Luminaire Eff (LER) 71.0 2000 2 ⅝" (67mm) 14" (356mm) 3000 Ordering information Type Size Surface Prismatic Luminaire 14" 14" 14" 24" 24" WB4B432 Candlepower Curve Reference data 2 ⅝" (67mm) Dominaire Surface Wrap Luminaire HI*, P2** SO* 1 - 2 Lamp Electronic TT5 (40W) SB*, PR** IB* WB4B432UNVH4 Example page 4.216 Ballast: Specify voltage (120, 277 or UNV) and type and add as suffix, e.g. UNVHI. x x x x x Lamp qty –type 48 ¾" 48 ¾" 48 ¾" 48 ⅝" 48 ⅝" UNV 2-T8 3-T8 4-T8 4-T8 2-TT5-40 H4 Voltage Ballast 120 = 120V See page 4.159 277 = 277V UNV= 120-277V Catalog no. WB4B232 WB4B332 WB4B432 WB2B417 WB2B2FT 1 - 3 Lamp Electronic T8 H3*, P3** O3* 1 - 4 Lamp Electronic T8 H4*, P4** O4* LOL T8 Dimming – PS * Instant start ** Program start Electrical/wiring options: For special wiring, fusing, electronic dimming ballasts or emergency pack, consult factory. 30˚ Canopy spacer: Suspends fixture 1 1/2" from surface. Order Catalog no. AC1 CSP. Stem and canopy sets: Suspend fixture 6", 12", 18" or 24" from surface. (Four per fixture is recommended.) Catalog no.: ASC6 CSP (6"); ASC12 CSP (12"); ASC18 CSP (18"); ASC24 CSP (24"). Fusing: Suffix: A (Internal fast-blow fusing). Suffix: C (Internal slow-blow fusing). Stems not available with 3 lamp unit. A Options See page 4.159 and page 4.216 (Elec. T8 Ballast only) Comprehensive lighting catalog 7th Edition 4.159 Linear recessed and surface lighting – Specification LWBU Universal Wall mounted downlight or uplight/downlight LWBU232UNVHI Features • Universal luminaire that has uplight/downlight or downlight capabilities on the same fixture. Ordering information Size page 4.216 Downlight Ballast type <10THD <20THD Electronic T8 HI*, P2** SO* LOL T8 Dimming – PS Example * Instant start ** Program start 420 Lamp qty –type Catalog no. 7 ⅝" x 25 ½" 7 ⅝" x 37 ½" 7 ⅝" x 49 ½" 1-T8 LWBU117 LWBU125 LWBU132 7 ⅝" x 25 ½" 7 ⅝" x 37 ½" 7 ⅝" x 49 ½" 2-T8 LWBU217 LWBU225 LWBU232 LWBU132 LWBU Wall Mounted Downlight Luminaire Electrical/wiring options: For special wiring, fusing, electronic dimming ballasts or emergency pack, consult factory. Fusing: Suffix: A (Internal fast-blow fusing). Suffix: C (Internal slow-blow fusing). UNV 630 HI Options See page 4.160 and page 4.216 (Elec. T8 Ballast only) LWBU232UNVHI 1 & 2 Lamp Uplight/Downlight Efficiency 65.2% Spacing ratio 1.2 Ordering information Uplight lens cover removed for uplight/ downlight Example 90˚ 450 60˚ 0 7 ⅝"7 (194mm) ⅝" (194mm) 450 Size Uplight / Downlight Candlepower Curve Reference data 3 1163" 116" (78mm) (78mm) Type 30˚ A Voltage Ballast 120 = 120V See page 4.160 277 = 277V UNV= 120-277V Uplight Lens Cover Uplight Lens Cover Uplight lens cover for downlight only 90˚ 60˚ • For over mirror, over bed, corridor, stairwell and bulletin Type board applications. Ballast: Specify voltage (120, 277 or UNV) and type and add as suffix, e.g. UNVHI. 0 210 7 ⅝" (194mm) • Invisible steel latches align refractor to housing. Options & accessories Efficiency 62.4% Spacing ratio 1.2 3 116" (78mm) • Low brightness linear prismatic virgin acrylic refractor. Candlepower Curve Reference data Uplight Lens Cover • Low brightness controlled downlighting and uplighting/ downlighting. • Individual or continuous rows. 1 & 2 Lamp Downlight Lamp qty –type 7 ⅝" x 25 ½" 7 ⅝" x 37 ½" 7 ⅝" x 49 ½" 1-T8 LWBU117 LWBU125 LWBU132 7 ⅝" x 25 ½" 7 ⅝" x 37 ½" 7 ⅝" x 49 ½" 2-T8 LWBU217 LWBU225 LWBU232 LWBU132 LWBU Wall Mounted Uplight/Downlight Luminaire UNV 45˚ Catalog no. HI Voltage Ballast 120 = 120V See page 4.160 277 = 277V UNV= 120-277V 900 30˚ A Options See page 4.160 and page 4.216 (Elec. T8 Ballast only) Controlled uplight/ downlight (LWBU) 4.160 Philips Lightolier For complete specification information visit www.lightolier.com Specification – Linear recessed and surface lighting LSW Wall mounted/ceiling mounted LS4R232UNVHI 1 Lamp Downlight 6 ⅛" (155mm) Candlepower Curve Reference data 6 ⅛" (155mm) Efficiency 73.9% Spacing ratio 1.3 3 ⅞" (98mm) 3 ⅞" (98mm) 0 90˚ 400 60˚ Ordering information 800 Type LS4R232UNVHI SizeLS4R132UNVHI Lamp qty –type Catalog no. Prismatic Lens Luminaire 6" x 23 15⁄16" 6" x 47 15⁄16" 2-T8 LS2R217 LS4R232 UNV HI Example LS4R232 LSW Wall or Ceiling Mounted Luminaire 1200 • For ceiling or wall (vertically or horizontally) mounted applications. • Only 3 7/8" deep, meets Americans with Disabilities Act (wall mounted). • Low brightness .125 thick linear prismatic virgin acrylic refractor. • Invisible spring steel latches align refractor to housing. • 20 gauge cold rolled steel post painted baked white enamel end caps. • For over mirror, over bed, corridor, stairwell and bulletin board applications. 30˚ Options & accessories A Voltage Ballast 120 = 120V See page 4.161 277 = 277V UNV= 120-277V Features page 4.216 Ballast: Specify voltage (120, 277 or UNV) and type and add as suffix, e.g. UNVHI. Options See page 4.161 and page 4.216 Ballast type <10THD <20THD (Elec. T8 Ballast only) Electronic T8 HI*, P2** SO* LOL T8 Dimming – PS * Instant start ** Program start Electrical/wiring options: For special wiring, fusing, electronic dimming ballasts or emergency pack, consult factory. LS4R132UNVHI m) 2 Lamp Downlight UNVHI Efficiency 76.9% Spacing ratio 1.4 3 ⅞" (98mm) 3 ⅞" (98mm) Candlepower Curve Reference data 6 ⅛" (155mm) Fusing: Suffix: A (Internal fast-blow fusing). Suffix: C (Internal slow-blow fusing). 0 90˚ 190 60˚ Ordering information 380 Type LS4R132UNVHI Size Prismatic Lens Luminaire 6" x 23 15⁄16" 6" x 47 15⁄16" Example LS4R132 LSW Wall or Ceiling Mounted Luminaire Lamp qty –type 1-T8 UNV Catalog no. LS2R117 LS4R132 HI Voltage Ballast 120 = 120V See page 4.161 277 = 277V UNV= 120-277V 570 30˚ A Options See page 4.161 and page 4.216 (Elec. T8 Ballast only) Comprehensive lighting catalog 7th Edition 4.161 Linear recessed and surface lighting – Specification Deepcel Surface 2' x 4' & 2' x 2' 3" parabolic louver surface fluorescent luminaires DPB2S18LS332UNVH3 Efficiency 69.6% Spacing ratio 1.6 Electronic ballast 24" (610mm) Features • Only 5 1/2" deep. 8 Cell • Welded 20 gauge steel body. 8 Cell Candlepower Curve Reference data 5 ½" (140mm) Input watts (120V) 85.0W 8 Cell Cell 12 Cell 12 Cell 12 Cell 12 Cell 1212 Cell 5 ½" (140mm) • 45° mitered corners (body and louver). 2000 24" (610mm) • Side-mounted ballast for cooler operation. 3000 • 3" deep aluminum parabolic louver. • Matches Deepcel 2x2 and 2x4 recessed. • Perfectly uniform four-side black reveal. 9 Cell 9 Cell 24" (610mm) 9 Cell 12 Cell8 Cell 12 Cell 1216 Cell Cell1216 Cell 1618 Cell Cell 1824 Cell Cell1218 Cell Cell 24 Cell 2432 Cell Cell 32 Cell 32 Cell Cell • Spring-loaded latches. Ordering information • Reversible louver hinging. Type Cells Surface Parabolic 12 18 24 32 Example DPB2S18LS332 • Door jamb with integral positive light stop. • Flush end K.O.’s for smooth surface appearance (at end of row or individual). • Louver has polyethylene dust guard. • Meets NYC Code requirements. Size Lamp qty –type 2' x 4' Ballast: Specify voltage (120, 277 or UNV) and type and add as suffix, e.g. UNVHI. Ballast type <10THD <20THD Electronic T8 HI*, P2** SO* 1 - 3 Lamp Electronic T8 H3*, P3** O3* 1 - 4 Lamp Electronic T8 H4*, P4** O4* 1 - 3 Lamp Elec. TT5 (40W) I3* X3* 1 & 2 Lamp Elec. TT5 (40W) IB*, PR** SB* 12 Cell Options See page 4.162 and page 4.130 Candlepower Curve Reference data 8 Cell Efficiency 57.6% Spacing ratio 1.4 8 Cell 8Electronic Cell Cell 12 Cell 12 Cell 12 Cell 12 ballast Cell 1212 Cell Input watts (120V) 60.0W 600 60˚ 1200 2400 5 ½" 9 Cell (140mm) 9 Cell 30˚ 12 Cell 12 Cell 1216 9 Cell Cell Cell 16 Cell 1618 Cell Cell 18 Cell 1824 Cell Cell 24 Cell 2432 Cell Cell 24" (610mm) Ordering information Type Cells Surface Parabolic 9 12 16 9 9 9 12 12 Size Lamp qty –type 2' x 2' DPB2S9LS26U Deepcel Surface Surface 3" Parabolic Philips Lightolier 32 Cell A 24" (610mm) Example 4.162 24 Cell Ballast See page 4.162 5 ½" (140mm) Electrical/wiring options: For special wiring, fusing, electronic dimming ballasts or emergency pack, consult factory. Fusing: Suffix: A (Internal fast-blow fusing). Suffix: C (Internal slow-blow fusing). H3 (Elec. T8 Ballast only) 5 ½" (140mm) 24" (610mm) 18 Cell Voltage 120 = 120V 277 = 277V UNV= 120-277V DPB2S9LS26UUNVHI * Instant start ** Program start Stem and canopy sets: Suspend fixture 6", 12", 18" or 24" from surface. (Four per fixture is recommended.) Catalog no.: ASC6 CSP (6"); ASC12 CSP (12"); ASC18 CSP (18"); ASC24 CSP (24"). 16 Cell UNV Deepcel Surface Surface 3" Parabolic Louver finish: Low iridescence semi-specular is standard. Consult factory for other finishes. Catalog no. DPB2S12LS232 DPB2S18LS332 DPB2S24LS332 DPB2S32LS432 2-T8 3-T8 3-T8 4-T8 9 Cell page 4.130 30˚ 5 ½" (140mm) • Vertical grain on louver eliminates reflected lamp image on cross baffle. Options & accessories 60˚ 1000 2-T8 U6 2-T8 U6 2-T8 U6 3-T8 17W 3-TT5 Biax 3-T8U1.6 3-TT5 Biax 3-T8U1.6 Catalog no. DPB2S9LS26U DPB2S12LS26U DPB2S16LS26U DPB2S9LS317 DPB2S9LS3FT DPB2S9LS32U DPB2S12LS3FT DPB2S12LS32U UNV HI Voltage 120 = 120V 277 = 277V UNV= 120-277V Ballast See page 4.162 A Options See page 4.162 and page 4.130 (Elec. T8 Ballast only) For complete specification information visit www.lightolier.com Specification – Linear recessed and surface lighting Prismalyte Surface 2' x 4', 2' x 2' & 1' x 4' Premium specification lensed surface fluorescent luminaires PNB2SRAVA432UNVH4 Candlepower Curve Reference data Efficiency 60.2% Spacing ratio 1.3 5 ½" (140mm) Electronic ballast 24" (610mm) 60˚ 1200 Input watts (120V) 112W • 20 gauge steel housing. 2400 5 ½" (140mm) • Housing mitered corner detailing. • Only 5 1/2" deep. 24" (610mm) 3600 5 ½" (140mm) 24" (610mm) Features 30˚ Ordering information Type Size Surface Parabolic • Quick remove ballast covers. • Fully enclosed wiring. Lamp qty –type 2-T8 3-T8 4-T8 2' x 4' • Dual side wireways for cooler operation. Catalog no. • Available in three lens frame styles. PNB2SRAVA232 PNB2SRAVA332 PNB2SRAVA432 • Door jamb with positive light stop. • Positive spring-loaded or cam-action latches. • Available with floating or full size doors. • Aluminum doors with mitered corners. • Matches Prismalyte troffer (see page 4.122). PNB2SRAVA26UUNVHI Candlepower Curve Reference data Efficiency 57.3% Spacing ratio 1.4 5 ½" (140mm) Electronic ballast 24" (610mm) 60˚ 600 Input watts (120V) 60.0W 24" (610mm) 1800 30˚ Size Surface Parabolic Lamp qty –type Catalog no. PNB2SRAVA26U PNB2SRAVA3FT PNB2SRAVA32U 2-T8 U6 3-TT5 3-T8 U1.6 2' x 2' Options & accessories page 4.130 Special lenses: VA lens is standard virgin acrylic. For other available lenses, see page 4.130 Ballast type <10THD <20THD HI*, P2** SO* Electronic T8 Ordering information Type • Matches 1x4, 2x2, 2x4 Prismalyte Recessed. Ballast: Specify voltage (120, 277 or UNV) and type and add as suffix, e.g. UNVHI. 1200 5 ½" (140mm) • Meets NYC Code requirements. 1 - 3 Lamp Electronic T8 H3*, P3** O3* 1 - 4 Lamp Electronic T8 H4*, P4** O4* 1 - 3 Lamp Elec. TT5 (40W) I3* X3* 1 & 2 Lamp Elec. TT5 (40W) IB*, PR** SB* * Instant start ** Program start PNB1SRAVA232UNVHI Candlepower Curve Reference data Efficiency 58.4% Spacing ratio 1.2 5 ½" (140mm) Electronic ballast 600 60˚ Input watts (120V) 62.0W 12" (305mm) 1200 2400 30˚ Ordering information Type 5 ½" (140mm) Surface Parabolic 12" (305mm) Example PNB1SRAVA232 Prismalyte Surface Premium Lensed Surface Luminaire UNV Voltage 120 = 120V 277 = 277V UNV= 120-277V (Elec. T8 Ballast only) Size 1' x 4' Stem and canopy sets: Suspend fixture 6", 12", 18" or 24" from surface. (Four per fixture is recommended.) Catalog no.: ASC6 CSP (6"); ASC12 CSP (12"); ASC18 CSP (18"); ASC24 CSP (24"). Fusing: Suffix: A (Internal fast-blow fusing). Suffix: C (Internal slow-blow fusing). 5 ½" (140mm) 12" (305mm) Electrical/wiring options: For special wiring, fusing, electronic dimming ballasts or emergency pack, consult factory. The Prismalyte Surface box Available with your choice of 3 different Door frames. Lamp qty –type PNB1SRAVA132 PNB1SRAVA232 PNB1SRAVA332 1-T8 2-T8 3-T8 HI Ballast See page 4.163 Catalog no. To specify which Door frame you prefer, use door name abbreviation indicated in Catalog number (PNB2SRAVA232). A Options See page 4.163 and page 4.130 FA = Flush Aluminum Full-Size Door RA = Regressed Aluminum Full-Size Door RF = Regressed Aluminum Floating Door Comprehensive lighting catalog 7th Edition 4.163 Linear recessed and surface lighting – Specification Vision Smart Surface 1' x 4' Surface VRB1S8LS132UNVHI Features • Side mounted ballast for cooler operation. Efficiency 66.0% Spacing ratio 1.9 • 45° mitered corners (body and louver). • 3" deep cell aluminum parabolic louver (VRB). • • • • • • • • 5 ½" (140mm) Candlepower Curve Reference data • 20 gauge steel welded body. Electronic ballast 60˚ 300 Input watts (120V) 30.0W • Spring-loaded latches. 600 12" (305mm) • Perfectly uniform four side reveal. • Low-iridescence, semi-specular aluminum, s tandard. 900 • Louver has polyethylene dust guard. 30˚ • Meets NYC Code requirements. • Louver assembly can be replaced with any of 3 standard Philips Lightolier Door frames. Options & accessories page 4.216 Louver finish: Low iridescence semi-specular is standard. Consult factory for other finishes. Ballast: Specify voltage (120, 277 or UNV) and type and add as suffix, e.g. UNVHI. Ballast type <10THD <20THD Electronic T8 HI*, P2** SO* LOL T8 Dimming – PS * Instant start ** Program start Electrical/wiring options: For special wiring, fusing, electronic dimming ballasts or emergency pack, consult factory. Stem and canopy sets: Suspend fixture 6", 12", 18" or 24" from surface. (Four per fixture is recommended.) Catalog no.: ASC6 CSP (6"); ASC12 CSP (12"); ASC18 CSP (18"); ASC24 CSP (24"). 8 Cell 8 Cell 12 Cell 12 Cell 12 Cell 12 Cell Ordering information Type Surface Parabolic Cells 8 12 8 9 Cell 12 Example Size Lamp qty –type 1-T8 1-T8 1' x 4' 1' x 4' 9 Cell 12 Cell VRB1S8LS132 Vision Smart Surface 1' x 4' Catalog no. VRB1S8LS132 VRB1S12LS132 2-T8 VRB1S8LS232 12 Cell 16 Cell 16 Cell 18 Cell 2-T8 VRB1S12LS232 UNV 18 Cell 24 Cell HI Voltage 120 = 120V 277 = 277V UNV= 120-277V Ballast See page 4.164 24 Cell 32 Cell 32 Cell A Options See page 4.164 and page 4.216 (Elec. T8 Ballast only) Fusing: Suffix: A (Internal fast-blow fusing). Suffix: C (Internal slow-blow fusing). 4.164 Philips Lightolier For complete specification information visit www.lightolier.com Standard – Linear recessed and surface lighting 4" (102mm) SLB 2' x 4', 2' x 2' & 1' x4' 24" (610mm) 4" (102mm) High performance lensed surface fluorescent luminaires 24" (610mm) High quality surface luminaires with 4" deep housings. Door frames are extruded aluminum or steel. SLB series surface luminaires can be used in low plenum depth areas that require surface luminaires. SLB2SFSVA432UNVH4 24" (610mm) Candlepower Curve Reference data 4"4" (102mm) (102mm) Efficiency 67.1% Spacing ratio 1.3 Electronic ballast 24" (610mm) 4" 4" (102mm) (102mm) 24" (610mm) • Shallow 4" deep, 20 gauge steel housing. • Positive cam-action latches secure frame on either side. 1200 60˚ Input watts (120V) 112.0W • Matte black light seal on both ends to prevent light leaks. Options & accessories 3600 4" 4" 4" (102mm) (102mm) (102mm) 30˚ Ordering information Door frame Size Flush Steel Surface Luminaire Regressed Aluminum 2' x 4' 2' x 4' page 4.216 Special lenses: VA lens is standard virgin acrylic. For other available lenses, see page 4.130. Ballast: Specify voltage (120, 277 or UNV) and type and add as suffix, e.g. UNVHI. 24" (610mm) Type • Center mounted ballast compartment. • Snap-on wiring channel cover is removed without tools. 2400 24" (610mm) 12" 24" (305mm) (610mm) Features Catalog no. Ballast type <10THD <20THD 2-T8 3-T8 4-T8 SLB2SFSVA232 SLB2SFSVA332 SLB2SFSVA432 Electronic T8 2-T8 3-T8 4-T8 SLB2SRAVA232 SLB2SRAVA332 SLB2SRAVA432 Lamp qty –type SLB2SFSVA26UUNVHI Candlepower Curve Efficiency 63.6% Spacing ratio 1.3 Electronic ballast 24" (610mm) 4" (102mm) H3*, P3** O3* 1 - 4 Lamp Electronic T8 H4*, P4** O4* * Instant start ** Program start Reference data 4" (102mm) HI*, P2** SO* 1 - 3 Lamp Electronic T8 550 60˚ Input watts (120V) 60.0W Electrical/wiring options: For special wiring, fusing, electronic dimming ballasts or emergency pack, consult factory. Stem and canopy sets: Suspend fixture 6", 12", 18" or 24" from surface. (Four per fixture is recommended.) Catalog no.: ASC6 CSP (6"); ASC12 CSP (12"); ASC18 CSP (18"); ASC24 CSP (24"). Fusing: Suffix: A (Internal fast-blow fusing). Suffix: C (Internal slow-blow fusing). 1100 24" (610mm) Ordering information Type 1650 Door frame Size Surface Luminaire Lamp qty –type Flush Steel 2' x 2' 2-T8 U6 4-17W SLB2SFSVA26U SLB2SFSVA417 Regressed Aluminum 2' x 2' 2-T8 U6 4-17W SLB2SRAVA26U SLB2SRAVA417 SLB1SFSVA232UNVHI 24" (610mm) 4"4" (102mm) (102mm) 24" (610mm)4" (102mm) 4" 4" (102mm) (102mm) 12" (305mm) 24" (610mm) 24" (610mm) Ordering information Type Surface Luminaire Example Door frame Size Steel 24"Flush (610mm) 1' x 4' Regressed Aluminum 1' x 4' 24" (610mm) SLB1SFSVA232 SLB High Performance Lensed Surface 4" Luminaire (102mm) 4" 4" (102mm) Lamp qty –type (102mm) Candlepower Curve Reference data Efficiency 56.2% Spacing ratio 1.2 Electronic ballast 550 60˚ Input watts (120V) 62.0W Catalog no. SLB1SFSVA232 2-T8 SLB1SRAVA232 1650 The Prismalyte Surface box Available with your choice of 2 different door frames. To specify which door frame you prefer, use door name abbreviation indicated in catalog number (PNB2SRAVA232). 1100 2-T8 UNV 30˚ Catalog no. 30˚ HI Voltage Ballast 120 = 120V See page 4.165 277 = 277V UNV= 120-277V Options See page 4.165 and page 4.216 FS = Flush Steel RA = Regressed Aluminum (Elec. T8 Ballast only) Comprehensive lighting catalog 7th Edition 24" (610mm) 4" 4.165 Linear recessed and surface lighting – Standard Jet Star Lens 2 ½" (61mm) Surface 8 ¼" (108mm) JS4A232UNVHI 2 ½" (61mm) Features • Ideal for low ceiling height applications where recessed units cannot be used. • 2 13/16" total depth. 8 ¼" (108mm) 13 ¼" (339mm) Candlepower Curve Reference data • Step-back housing for an apparent depth of 1 3/4". • A shallow profile and linear prismatic sides combine to reduce ceiling contrast. • Virgin acrylic lens with one-piece extruded prismatic pattern 12 bottom and linear prism side walls. • Shielding hinges from either side (self-leveling). 2 ½" (61mm) Efficiency 85.4% Spacing ratio 1.3 Electronic 13 ¼"ballast (339mm) Candlepower Curve Reference data Efficiency 90.7% Spacing ratio 1.4 2 ½" (61mm) Electronic ballast 60˚ 550 Input watts (120V) 56.0W LER 78.2 • Full-length ballast cover snaps-in, snaps-out (no tools). Input watts (120V) 57.0W LER 81.6 1100 • Individual or continuous row installations. 60˚ 550 1100 • Suitable for mounting on low-density cellulose fiberboard surfaces. 30˚ 30˚ • Suitable for damp locations. Ordering information Type Size Jet Star Lens Luminaire 8 ¼" 8 ¼" 8 ¼" 8 ¼" Lamp qty –type x x x x 24" 24" 48" 96" 13 ¼" x 48" Catalog no. 2-T12 2-T8 2-T8 4-T8* JS2A220 JS2A217 JS4A232 JS8A232 4-T8 JS4B432 Example JS4A232 Jet Star lens Surface * 2-Lamps In Tandem - 4 Lamps Total UNV HI A Voltage Ballast 120 = 120V See page 4.166 277 = 277V UNV= 120-277V Options See page 4.166 and page 4.216 (Elec. T8 Ballast only) Jet Star Corridor Lens Surface JS4C132UNVHI Options & accessories page 4.216 Ballast type <10THD <20THD Electronic T8 HI*, P2** SO* 1 - 4 Lamp Electronic T8 H4*, P4** LOL T8 Dimming – PS O4* Electrical/wiring options: For special wiring, fusing, electronic dimming ballasts or emergency pack, consult factory. Canopy spacer: Suspends fixture 1 1/4" from surface. Order Catalog no. AC1 CSP. Stem and canopy sets: Suspend fixture 6", 12", 18" or 24" from surface. (Four per fixture is recommended.) Catalog no.: ASC6 CSP (6"); ASC12 CSP (12"); ASC18 CSP (18"); ASC24 CSP (24"). Fusing: Suffix: A (Internal fast-blow fusing). Suffix: C (Internal slow-blow fusing). 4.166 Philips Lightolier Electronic ballast Input watts (120V) 34.3W LER 77.7 5 ½" (140mm) Ordering information Type Size Jet Star Lens Luminaire 5 ½" 5 ½" 5 ½" 5 ½" 5 ½" 5 ½" 5 ½" 5 ½" * Instant start ** Program start For 20W T12, use Ballast suffix PL. Efficiency 84.3% Spacing ratio 1.5 1 ⅞" (48mm) 4 ¼" (108mm) Ballast: Specify voltage (120, 277 or UNV) and type and add as suffix, e.g. UNVHI. Example 24" 24" 24" 24" 48" 48" 96" 96" JS4C132 Jet Star Corridor lens Surface 60˚ 280 560 Lamp qty –type x x x x x x x x Candlepower Curve Reference data 4 ⅛" (105mm) 1-T12 1-T8 2-T12 2-T8 1-T8 2-T8 2-T8* 4-T8** 30˚ Catalog no. JS2C120 JS2C117 JS2C220 JS2C217 JS4C132 JS4C232 JS8C132 JS8C232 UNV HI Voltage Ballast 120 = 120V See page 4.166 277 = 277V UNV= 120-277V *1-Lamp in tandem - 2 lamps total **2-Lamps in tandem - 4 lamps total For T5 options consult factory A Options See page 4.166 and page 4.216 (Elec. T8 Ballast only) For complete specification information visit www.lightolier.com Professional – Linear recessed and surface lighting Task lighting Contents Pristine > 4.168 Taskmaster I > 4.169 Taskmaster II > 4.169 Taskmaster Solid Front T8 > 4.170 Taskmaster Solid Front T5 > 4.171 Comprehensive lighting catalog 7th Edition 4.167 Linear recessed and surface lighting – Professional Pristine T2 Task lighting Aluminum Reflector Nine Foot Straight Cord Pristine ¾" Aluminum (19mm) Reflector Features Nine Foot Straight Cord 1 ⅜" (35mm) ¾" (19mm) • Architecturally pleasing rounded slim profile only 3/4" deep x 4-3/4" wide. 4 ¾" (121mm) 1 ⅜" (35mm) • Provides median foot candle level of 55 on 2' x 5' desk top. 4 ¾" (121mm) • Prismatic acrylic spread lens. 5 116" (132mm) • Flush push button switch. 12" (305mm) • Electronic program start <10 THD ballast. • Lamp T2 13W, CRI= 80, color temperature 3500K, lamp is included. 5 116" (132mm) 12" (305mm) 4 ¾" (121mm) • Nine foot straight black cord. • Baked pewter polyester enamel finish for cord and plug. • Baked white polyester enamel finish for hardwire option. • Meets New York City requirements for task lighting. Ordering information Please consult factory for any further options. Aluminum Reflector Nine Foot Straight Cord ¾" (19mm) 1 ⅜" (35mm) 4 ¾" (121mm) 5 116" (132mm) 4 ¾" (121mm) 22" (559mm) Type Color Length 22" (559mm) Pristine One Lamp with Cord and Plug Lamp qty –type Lamp watts Catalog no. Pewter 22” 1-T2 13W PC2P13T2120PTCPB Pristine One Lamp with Chicago Style Plug Pewter 22” 1-T2 13W PC2P13T2120PTCPBCH Pristine 12" (305mm) Hard wire series Aluminum 4 ¾" (121mm) T2 Lamp Reflector Pristine ¾" (19mm) 22" (559mm) Aluminum Reflector Aluminum Reflector ¾" (19mm) T2 Lamp 1 ¼" (32mm) T2 Lamp ¾" (19mm) 1 ¼" (32mm) 4 ¾" (121mm) 1 ¼" (32mm) 6 316" (161mm) 4 ¾" (121mm) Backwall 4 ¾" (121mm) 6 316" (161mm) 3" (76mm)3 6 16" (161mm) 1 ¼" (32mm) 3" (76mm) 1 ¼" 3" (76mm) 2 ~ ⅞" K.O. (32mm) Center Line 1 ¼" (32mm) 2 ~ ⅞" K.O. 6" (153mm) 2 ~ ⅞" K.O. 2 ~ ⅞" K.O. Center Line 5 116" (132mm) Desktop 4 ¾" (121mm) 5 116" 6" (153mm)(132mm) 2 ~ ⅞" K.O. 5 116" (132mm) Center Line 8" 6" (153mm) (203mm) 2 ~ ⅞" K.O. 8" (203mm) 8" (203mm) 4 ¾" (121mm) 4 ¾" (121mm) 12" (305mm) 22" (559mm) 4.168 Philips Lightolier 12" (305mm) Ordering information 12" (305mm) Type Color Length 22" (559mm) Lamp qty –type Pristine One Lamp Hardwire White 22” 22" (559mm) 1-T2 Lamp watts 13W Catalog no. PC2W13T2120PTHW For complete specification information visit www.lightolier.com Specification – Linear recessed and surface lighting Taskmaster I Under shelf luminaires Taskmaster 1 ⅛" (29mm) 5" (127mm) Ordering information Type Length Lamp watts/Type Taskmaster I (One Lamp) TSL0018W BPR 8PH TSL0113W BPR 13PH 8PH/13PH (1 each) TSL1813W BPR Taskmaster I (Two Lamp) 24 ¼" 42 ½" 8PH 13PH Example 1 ⅛" (29mm) 1 ⅞" (48mm) Features Catalog no. 12 ¼" 21 ¼" 33 ½" • 1 1/8" shallow depth. • Five nominal lengths: 12", 21", 24", 33", 42". • Grounded convenience outlet (optional). TSL0028W BPR TSL0213W BPR • On/off rocker switch (included in supply pack). • Baked white enamel finish. Options & accessories TSL0018W BPR Accessories that will ship separately order the following: Taskmaster I Under Shelf Luminaire GLR-B (6 pack of 3 amp fusing) RIF-SUPR (1-RFI suppressor) 5" (127mm) For electronic ballast, substitute TSLP for TSL, e.g: TSLP0018W BPR. CONV OUTLET 10-pack (10 pack of outlets and hardware) Attractive, unobtrusive lighting 5¼" (134mm) Accessories are for field installation. Taskmaster II Under shelf luminaires Taskmaster 1 ⅞" (48mm) 5¼" (134mm) Features • 1 7/8" shallow depth. Ordering information Type Length Taskmaster II 18 ⅛" 24 ⅛" 36 ⅛" 48 ⅛" 24 ⅛" 36 ⅛" 48 ⅛" Lamp qty –type TS-T12 TS-T12 TS-T12 TS-T12 T8 T8 T8 Lamp watts 15W 20W 30W 40W 17W 25W 32W • Four nominal lengths: 18", 24", 36", 48". Catalog no. • Grounded convenience outlet (optional). TCU15W120P BPR TCU20W120P BPR TCU30W120P BPR TCU40W120P BPR TCU20WUNVRO BPR TCU30WUNVRO BPR TCU40WUNVRO BPR • On/off rocker switch, standard (included in supply pack). • Baked white enamel finish. Options & accessories Accessories that will ship separately order the following: GLR-B (6 pack of 3 amp fusing) RIF-SUPR (1-RFI suppressor) CONV OUTLET 10-PACK (10 pack of outlets and hardware) Accessories are for field installation. Example TCU 40 W UNV RO BPR Lamp/fixture Bulk pack Taskmaster II length/watts Finish Voltage Ballast rocker switch Undershelf 15 = 15W TS T12 (Nom. 18") W = White 120 = 120V P = Standard Warning (277 BPR) Bulk Luminaire 20 = 20W TS T12 or 17W T8 (Nom. 24") (T12 Only) Magnetic T12 pack rocker switch can 30 = 30W RS T12 or 25W T8 (Nom. 36") UNV= 120-277V RO = Rapid Start not be installed on fixture 40 = 40W RS T12 or 32W T8 (Nom. 48") (Elec. T8 Ballast only) <10THD T8 if 277V is being run. Comprehensive lighting catalog 7th Edition 4.169 Linear recessed and surface lighting – Specification Taskmaster Solid Front T8 Specification undershelf luminaire Taskmaster 5 ¼" (133mm) Features ½" (13mm) Dia. K.O. This End Only • 1 ¾” shallow depth. • Three nominal lengths: 24", 36" , 48" ⅝" (16mm) • Specification grade under shelf luminaire. • Solid front design. 1 ¾" (44mm) • Lens removable without tools for easy maintenance. • 100% acrylic linear prismatic lens to obscure lamp image and uniformly distribute light output ⅞" (22mm) Dia. K.O. Each End " (11mm) Dia. K.O. Each End 7 16 • Lamp T8, CRI=70, color temp 3500K , is standard and included. • Paint after fabrication with white polyester paint finish. • On/off rocker switch (included in supply pack) 24 116" (611mm) 2 716" (62mm) 120 volt use only. • Universal voltage. ⅞" (22mm) Dia. K.O. (2) (One Top/One Back) " (5mm) Dia. Hole (4) (2 Top/2 Back) 3 16 Options & accessories 5 ¼" (133mm) Accessories that will ship separately order the following: GLR-B (6 pack of 3 amp fusing) RIF-SUPR ( 1-RFI suppressor) 4 ¼" (108mm) CONV OUTLET (10 PACK) CL Keyhole K.O. (2) 36 116" (916mm) 2 716" (62mm) ⅞" (22mm) Dia. K.O. (2) (One Top/One Back) " Dia. Hole (4) (2 Top/2 Back) 3 16 5 ¼" (133mm) CL 4 ¼" (108mm) Keyhole K.O. (2) 48 116" (1221mm) 2 716" (62mm) " Dia. Hole (4) (2 Top/2 Back) ⅞" (22mm) Dia. K.O. (2) (One Top/One Back) 3 16 5 ¼" (133mm) CL Keyhole K.O. (2) 4 ¼" (108mm) Ordering information Type Length Lamp qty –type 24 1 ⁄16" 36 1 ⁄16" 1 Taskmaster 48 ⁄16" Sold Front T8 24 1 ⁄16" 36 1 ⁄16" 48 1 ⁄16" TCF Example 1 32 Lamp watts Catalog no. Electronic ballast type 1-T8 17W 25W 32W TCF117WUNVRO BPR TCF125WUNVRO BPR <10 Program Rapid Start TCF132WUNVRO BPR 1-T8 17W 25W 32W TCF117WUNVHI BPR TCF125WUNVHI BPR TCF132WUNVHI BPR W UNV RO <10 Instant start BPR Lamp/fixture Bulk pack Taskmaster Lamp length/watts Finish Voltage Ballast rocker switch Solid Front T8 Specification 1 = Number 17 = 17W T8 (Nom 24") W = White UNV= 120-277V HI = Instant start Can only be installed Undershelf Luminaire of Lamps 25 = 25W T8 (Nom 36") (Elec. T8 Ballast only) <10THD T8 in a 120 volt application 32 = 32W T8 (Nom 48") RO = Rapid Start 4.170 Philips Lightolier <10THD T8 For complete specification information visit www.lightolier.com Specification – Linear recessed and surface lighting Taskmaster Solid Front T5 Specification undershelf luminaire Taskmaster 5" (127mm) Features ½" (13mm) • 1 1/8” shallow depth. 1 ⅛" (29mm) • Three nominal lengths: 22”, 34” , 46” • Specification grade under shelf luminaire. • Solid front design. ⅝" (16mm) Dia. .53" (13mm) Dia. K.O. (6) (3 Top/3 Back) • Lens removable without tools for easy maintenance. • 100% acrylic linear prismatic lens to obscure lamp image and uniformly distribute light output 22 ¾" (578mm) 1 ½" (38mm) • Lamp T5, CRI=80, color temp 3500K, is standard and included. 316" (5mm) Dia. Hole (2) 11 ⅜" (289mm) • Paint after fabrication with white polyester paint finish. 2 ½" (64mm) 1 ¾" (45mm) • On/off rocker switch (included in supply pack) 120 volt use only. 5" (127mm) • Universal voltage. Options & accessories 1 ¾" (45mm) 2 ⅜" (60mm) Accessories that will ship separately order the following: Keyhole K.O. (2) GLR-B (6 pack of 3 amp fusing) CONV OUTLET (10 pack) 34 ½" (876mm) 1 ½" (38mm) 17 ¼" (438mm) 316" (5mm) Dia. Hole (2) .53" (13mm) Dia. K.O. (6) (3 Top/3 Back) 2 ½" (64mm) 1 ¾" (45mm) 5" (127mm) 1 ¾" (45mm) 2 ⅜" (60mm) Keyhole K.O. (2) 46 ¼" (1175mm) 1 ½" (38mm) 23 ⅛" (587mm) .53" (13mm) Dia. K.O. (6) (3 Top/3 Back) " (5mm) Dia. Hole (2) 3 16 1 ½" (38mm) 2 ½" (64mm) 1 ¾" (45mm) 5" (127mm) 1 ¾" (45mm) 2 ⅜" (60mm) Keyhole K.O. (2) Ordering information Type Length Lamp qty –type 22 ¾” Taskmaster 34 ½” Sold Front T5 46 ¼” Example TSF 1-T5 Lamp watts 14W 21W 28W 1 Taskmaster Lamp Solid Front T8 Specification 1 = Number Undershelf Luminaire of Lamps Catalog no. Electronic ballast type TSF114WUNVPG BPR TSF121WUNVPG BPR TSF128WUNVPG BPR <10 Program Rapid Start 28 W UNV PG Lamp/fixture length/watts Finish Voltage Ballast 14 = 14W T5 (Nom 22") W = White UNV= 120-277V HI = Program Rapid Start 21 = 21W T5 (Nom 34") (Elec. T5 Ballast only) <10THD T5 28 = 28W T5 (Nom 46") BPR Bulk pack rocker switch Can only be installed in a 120V application Comprehensive lighting catalog 7th Edition 4.171 Linear recessed and surface lighting Special purpose & industrial Special purpose luminaires that address vandal, wet and cleanroom application needs. Industrial lighting for enclosed or open luminaires where special construction is provided to meet concerns of hazardous and industrial areas for proper and safe lighting levels. 4.172 Philips Lightolier For complete specification information visit www.lightolier.com Linear recessed and surface lighting Contents Fluorescent High & Low Bays > 4.174 Cleanguard Class > 4.186 Hazardline > 4.188 Sealatron > 4.190 Cleanguard Wet > 4.192 Cleanlite > 4.193 Guardsman Vandal Resistant > 4.194 IC Series > 4.198 TU Turret Industrial > 4.200 KD/KW Industrial > 4.201 Comprehensive lighting catalog 7th Edition 4.173 Linear recessed and surface lighting – Professional Fluorescent high & low bays Current statistics reveal 65% of the energy is being consumed by the commercial and industrial markets and 22% of this energy is being utilized for lighting alone. Smart business managers have discovered the incredible energy savings of up to 50% by replacing traditional HID high bay fixtures with efficient linear fluorescent T5HO and T8 luminaires. These are the ideal green solution and have the added benefits of high Philips Lightolier, illumination uniformity and instant-on starting. A wide variety of T5 and T8 fluorescent fixtures are offered by Philips Lightolier for high and low bay lighting, all providing exceptional features for the application they were designed for. Here are some features you may want to consider when choosing a fluorescent high bay. Light beam 1. Selecting the right reflector is just as important as choosing the right luminaire. Reflectors determine how light is distributed in a space. Each reflector design has a specific light distribution function that is suited to certain applications better than others. Contoured Miro IV specular reflector Flat Miro IV specular reflector Flat white reflector Features a mirrored silver finish designed to concentrate beam spread and optimize lamp performance making it ideal to concentrate light on the racks of a warehouse or a store. For assembly plant as well as retail open area, a flat design reflector with mirrored silver finish produces very wide light distribution and optimizes efficiency. In gymnasiums, low-glare and wide light distribution which can be provided by a flat white reflector are a must. 90° 90° 90° 0° 90° 90° 90° 0° 0° Uplight vs. downlight only Motion sensors for additional savings 2. A well-lit, inviting ceiling appearance contributes to a store's or working's positive 3. By including occupancy sensor controls, the energy reduction is even greater, ambience. Darker ceilings produce a more closed-in feeling, uncomfortable to most people. Uplight reduces the cave effect, expands the space and makes it look cleaner. especially in areas of a facility that have limited traffic. Unlike HID lamping, adding occupancy sensors to T5HO and T8 systems is relatively easy and inexpensive. If the addition of a sensor makes you nervous, consider using the Smart TriLyte turnkey solution which has the technology to optimize lamp life. Whether it is for industrial, recreational or commercial uses, you will find that Philips Lightolier’s fluorescent high bays deliver great lighting packages, superior energy efficiency and occupancy sensing capabilities. 4.174 Philips Lightolier For complete specification information visit www.lightolier.com Professional – Linear recessed and surface lighting Fluorescent high bay Selection chart Trilyte Smart Trilyte Trilyte Nordik Gymlyter The best design in its category including ballast ventilation and body strength. Most versatile high bay in regards to application, especially in industrial aisles. TriLyte including Philips Alto low mercury lamps, Advance electronic ballast and a sensor optimizing lamp life and energy savings. Guaranteed for 3 years. The same light output at -18°C as the regular TriLyte at 25°C, making it perfect for cold storage. Highly resistant, full body luminaire with strong wireguard. Smart Trilyte 4 6 ● ● ● ● ● ● ● Trilyte Nordik 4 6 T5HO ● ● 2, 3, 4, 4T 6 ● Gymlyter ● ● ● ● ● ● ● ● ● ● ● ● ● ● STD ● ● ● STD ● ● ● ● ● ● ● STD ● ● Warranty ● Lamps ● Wireguard ● Door ● Sensor ● Stern ● Chain Retail ● Pendant Recreative ● Surface Industrial ● Accessories Hot Environments** Flat White 6 Mounting Cold Environments* Flat MIRO IV 2, 3, 4, 4T Trilyte Downlight/ Uplight Contoured MIRO IV Application Downlight Reflector T8 Distribution T5 Lamp Wide Narrow Design ● STD 3 years STD STD ● STD = Standard T = Lamps in tandem (e.g. 4T means 8 lamps total) **Rated for use from 5°C to 55°C ambient (without lens). **Rated for use from -18°C to 5°C ambient. For any special solution, contact your Philips Lightolier representative. Comprehensive lighting catalog 7th Edition 4.175 Linear recessed and surface lighting – Professional TriLyte Narrow Narrow-body 2, 3 & 4 lamp lowbay surface/pendant luminaire Designed for Trade (commercial spaces), Recreational and Industrial locations, TriLyte provides much needed versatility in lowbay applications. Using the appropriate lamp, wattage and reflector options, this narrow-body version is also suitable for highbay lighting, particularly retail outlets and indoor sports facilities. Its low-profile housing (almost 1" shallower than most competing models) is perfect for areas that place a premium on luminaire appearance. Dual-circuit TriLyte equipped with optional motion sensor delivers added lighting control flexibility for industrial applications. Features • Sturdy one-piece post-painted housing providing clean, smooth,installation-friendly corners. • Side-mounted ballast for low 2-3/4" profile. FH4C4DXX454120PV RCP C.U. 1 63 2 57 3 51 4 45 5 41 6 37 7 33 • Accepts emergency battery packs. 8 30 • Available motion sensor allows for total lighting control, added energy savings. 9 27 10 24 17" (432mm) • Mounting heights from 12' to 45' with suitable lampingreflector lens selection. 2 ¾" (70mm) • 2, 3 and 4-lamp versions (cross-section view). 13 ⅜" (340mm) • Available in 4' and 8' lengths. • Choice of contoured specular, flat specular or flat white reflector. 17 " (432mm) • Contoured specular reflector offers optimum performance and 95% reflectivity (not available on 2-lamp model). 36" (914mm) • Choice of stem, surface or chain mounting. Options & accessories 49 ½" (1257mm) Ballast: Specify voltage (120, 277 or UNV) and add as suffix, e.g. 120PU. 8 ¾" (222mm) Ballast type <10THD Elect. I.S. T8, (1) 4-Lamp H4 Elect. I.S. T8, (1) 4-Lamp & (1) 2-Lamp H5 Elect. I.S. T8, (2) 4-Lamp H7 Elect. P.S. T5/T5HO, (1) 2-Lamp PG Elect. P.S. T5/T5HO, (1) 3-Lamp PU Elect. P.S. T5/T5HO, (1) 4-Lamp PV Elect. P.S. T5/T5HO, (1) 4-Lamp & (1) 2-Lamp P6 Elect. P.S. T5/T5HO, (2) 3-Lamp P7 Elect. P.S. T5/T5HO, (2) 4-Lamp P8 one 4-Lamp ballast to operate outside lamps one 4-lamp ballast to operate inside lamps one 4-Lamp ballast to operate outside lamps one 2-lamp ballast to operate inside lamps one 3-Lamp for 1, 3, & 5 and one 3-Lamp for 2, 4, & 6 one 4-Lamp for 1, 3, & 5 and one 4-Lamp for 2, 4, & 6 Narrow-Body 4' Candlepower Curve Reference data Efficiency 89.2% Spacing ratio 1.3 Electronic ballast 60˚ 3000 Input watts (120V) 58W LER FI-T 6.0 6000 9000 30˚ Application data* Luminaire spacing FC W/Sq Ft 300' x 400' x 25' Space 17' on center 50 0.81 120' x 80' x 28' Space 16' on center 55 0.98 300' x 400' x 25' Space 14' on center 75 1.15 * Average Footcandles Maintained. Total LLF = 0.84. Reflectance: 80% Ceiling, 50% Wall, 20% Floor. 54W T5HO lamp rated at 4400 lumens at 25°C. 17 " (432mm) 36" (914mm) 98 ¼" (2496mm) 36" (914mm) Consult your representative for other ballast options. Electrical/wiring options: Consult your Philips Lightolier representative. Stem and canopy sets 4 stems required per luminaire. Order cat. no. ASC12 CSP (12"), ASC18 CSP (18"), ASC24 CSP (24"), ASC36 CSP (36"), ASC48 CSP (48"). Fusing: Suffix: A (Internal fast-blow fusing). Suffix: C (Internal slow-blow fusing). 8 ¾" (222mm) Narrow-Body 8' Chain hanger kit: 2 kits required per luminaire. Order catalog number EE9HC. VA = Pattern 12 prismatic lens made of virgin acrylic (.095" nominal). Complete with hinged white wireguard. Wireguard/lens: Variety of shielding options available. Luminaire-mounted motion sensor: 360° coverage. Field installed. Only available on luminaires with contoured specular reflectors. Order catalog number FH360. Remote-mounted motion sensor: Narrow coverage. Field installed. Order catalog number FH110. 4.176 Philips Lightolier XX = Version without lens shielding. WW = W hite hinged wireguard only (no lens), 9-gauge wire adding rigidity to luminaire. VI = Pattern 12 prismatic lens made of virgin acrylic (.125" nominal). Complete with hinged white wireguard. For complete specification information visit www.lightolier.com Professional – Linear recessed and surface lighting TriLyte Narrow Narrow-body 2, 3 & 4 lamp lowbay surface/pendant luminaire Designed for Trade (commercial spaces), Recreational and Industrial locations, TriLyte provides much needed versatility in lowbay applications. Using the appropriate lamp, wattage and reflector options, this narrow-body version is also suitable for highbay lighting, particularly retail outlets and indoor sports facilities. Its low-profile housing (almost 1" shallower than most competing models) is perfect for areas that place a premium on luminaire appearance. Dual-circuit TriLyte equipped with optional motion sensor delivers added lighting control flexibility for industrial applications. Ordering information for T5 Type Lamp qty/type Lamp/luminaire nominal length Prismatic Lens (VI) with Wireguard 2-T5HO 3-T5HO 4-T5HO 6-T5HO 8-T5HO 48" 48" 48" 96" tandem 96" tandem White Wireguard with No Lens 2-T5HO 3-T5HO 4-T5HO 6-T5HO 8-T5HO 48" 48" 48" 96" tandem 96" tandem Luminaire Catalog no. width 17" FH4W4DVI254UNVPG FH4C4DVI354UNVPG FH4C4DVI454UNVPG FH8C4DVI354UNVP6 FH8C4DVI454UNVP8 17" FH4W4DWW254UNVPG FH4C4DWW354UNVPG FH4C4DWW454UNVPG FH8C4DWW354UNVP6 FH8C4DWW454UNVP8 Ordering information for T8 Type Lamp qty/type Lamp/luminaire nominal length Prismatic Lens (VI) with Wireguard 2-T8 3-T8 4-T8 6-T8 8-T8 48" 48" 48" 96" tandem 96" tandem White Wireguard with No Lens 2-T8 3-T8 4-T8 6-T8 8-T8 48" 48" 48" 96" tandem 96" tandem Example FH4W4DWW454 Basic catalog no. TriLyte Luminaire Luminaire Catalog no. width 17" FH4W4DVI232UNVHI FH4C4DVI332UNVH3 FH4C4DVI432UNVH4 FH8C4DVI332UNVH5 FH8C4DVI432UNVH7 17" FH4W4DWW232UNVHI FH4C4DWW332UNVH3 FH4C4DWW432UNVH4 FH8C4DWW332UNVH5 FH8C4DWW432UNVH7 UNV PV Acronyms used CU = Coefficients of utilization FC = Footcandles A IS = Instant start LLF = Light loss factor Voltage Ballast Options 120 = 120V See previous page See previous page 277 = 277V UNV= 120-277V PS = Program start RCR = Room cavity ratio THD = Total harmonic distortion Numbering logic FH 4 W 4 D WW 4 Lamp qty in a luminaire cross-section Luminaire type Luminaire length Body style Width Type Lens/shielding FH = TriLyte 4 = 4' 4 = 17" D = Downlight C = Contoured Specular Reflector VA = Prismatic Lens 2 = 2 Lamps VA with Wireguard 3 = 3 Lamps VI = Prismatic Lens 4 = 4 Lamps VI with Wireguard S = Flat Design Specular Reflector WW = Wireguard, White /No Lens 8 = 8' W = Flat Design White Reflector 54 UNV PV Lamp/type Voltage Ballast 28 = T5 28W 120 = 120V 32 = T8 32W 277 = 277V See previous See previous page page Options 54 = T5HO 54W UNV= 120-277V XX = No Shielding Comprehensive lighting catalog 7th Edition 4.177 Linear recessed and surface lighting – Professional TriLyte Wide Wide-body 6 lamp highbay surface/pendant luminaire Designed for Trade (commercial spaces), Recreational and Industrial locations, TriLyte provides much needed versatility in highbay applications. Using the appropriate lamp, wattage and reflector options, this wide-body version is also suitable for lowbay lighting, particularly retail outlets and indoor sports facilities. Its low-profile housing (almost 1" shallower than most competing models) is perfect for areas that place a premium on luminaire appearance. Dual-circuit TriLyte equipped with optional motion sensor delivers added lighting control flexibility for industrial applications. Features • Sturdy one-piece post-painted housing providing clean, smooth, installation-friendly corners. • Side-mounted ballast for low 2-3/4" profile. • Mounting heights up to 45'. FH4C5DXX654UNVP6 23 ⅛" (587mm) • 6-lamp versions only (cross-section view). • Available in 4' lengths only. • Choice of contoured specular or flat white reflector. • Contoured specular reflector offers optimum performance and 95% reflectivity. 19 ⅝" (498mm) 2 ¾" (70mm) 23 ⅛" (587mm) • Choice of stem, surface or chain mounting. • Accepts emergency battery packs. RCP C.U. 1 100 2 92 3 85 4 79 5 72 • Available motion sensor allows for total lighting control, added energy savings. 6 67 7 62 Options & accessories 8 58 9 53 10 49 Ballast: Specify voltage (120, 277 or UNV) and add as suffix, e.g. UNVPG. 36" (914mm) Ballast type <10THD Elect. I.S. T8, (1) 4-Lamp & (1) 2-Lamp H5 Elect. P.S. T5/T5HO, (1) 4-Lamp & (1) 2-Lamp P6 Elect. P.S. T5HO, (2) 3-Lamp P7 one 4-Lamp ballast to operate outside lamps one 2-lamp ballast to operate inside lamps one 3-Lamp for 1, 3, & 5 and one 3-Lamp for 2, 4, & 6 Consult your representative for other ballast options. Candlepower Curve Reference data Efficiency 90.0% Spacing ratio 1.3 Electronic ballast 60˚ 3000 Input watts (120V) 234W LER 1.00 6000 9000 30˚ Application data* Luminaire spacing FC W/Sq Ft 120' x 80' x 28' Space 240 sq ft per lum. 80 1.5 120' x 80' x 28' Space 20' on center 50 1.9 300' x 400' x 25' Space 18' on center 75 1.1 * Average footcandles maintained. Total LLF = 0.84. Reflectance: 80% Ceiling, 50% Wall, 20% Floor. 54W T5HO lamp rated at 4400 lumens at 25°C. 49 ½" (1257mm) ** Average footcandles maintained. Total LLF = 0.84. Reflectance: 50% Ceiling, 30% Wall, 20% Floor. 54W T5HO lamp rated at 4400 lumens at 25°C. 15" (381mm) Electrical/wiring options: Consult your Philips Lightolier representative. Stem and canopy sets: 4 stems required per luminaire. Order cat. no. ASC12 CSP (12"), ASC18 CSP (18"), ASC24 CSP (24"), ASC36 CSP (36"), ASC48 CSP (48"). Fusing: Suffix: A (Internal fast-blow fusing). Suffix: C (Internal slow-blow fusing). VA = Pattern 12 prismatic lens made of virgin acrylic (.095" nominal). Complete with hinged white wireguard. Chain hanger kit 2 kits required per luminaire. Order catalog number EE9HC. Wireguard/lens Variety of shielding options available. Luminaire-mounted motion sensor 360° coverage. Field installed. Only available on luminaires with contoured specular reflectors. Order cat. no. FH360. Remote-mounted motion sensor Narrow coverage. Field installed. Order catalog number FH110. 4.178 Philips Lightolier XX = Version without lens shielding. WW = W hite hinged wireguard only (no lens), 9-gauge wire adding rigidity to luminaire. VI = Pattern 12 prismatic lens made of virgin acrylic (.125" nominal). Complete with hinged white wireguard. For complete specification information visit www.lightolier.com Professional – Linear recessed and surface lighting TriLyte Wide Wide-body 6 lamp highbay surface/pendant luminaire Designed for Trade (commercial spaces), Recreational and Industrial locations, TriLyte provides much needed versatility in highbay applications. Using the appropriate lamp, wattage and reflector options, this wide-body version is also suitable for lowbay lighting, particularly retail outlets and indoor sports facilities. Its low-profile housing (almost 1" shallower than most competing models) is perfect for areas that place a premium on luminaire appearance. Dual-circuit TriLyte equipped with optional motion sensor delivers added lighting control flexibility for industrial applications. Ordering information for T5 Type Lamp qty/type Lamp/luminaire nominal length Luminaire Catalog no. width Prismatic Lens (VI) with Wireguard 6-T5HO 48" 23" FH4C5DVI654UNVP6 White Wireguard with No Lens 6-T5HO 48" 23" FH4C5DWW654UNVP6 Lamp qty/type Lamp/luminaire nominal length Luminaire width Prismatic Lens (VI) with Wireguard 6-T8 48" 23" FH4C5DVI632UNVH5 White Wireguard with No Lens 6-T8 48" 23" FH4C5DWW632UNVH5 Ordering information for T8 Type Example Catalog no. Acronyms used FH4W5DWW654 Basic Catalog no. TriLyte Luminaire UNV CU = Coefficients of utilization FC = Footcandles P6 IS = Instant start Voltage Ballast Options 120 = 120V See previous page See previous page 277 = 277V UNV= 120-277V LLF = Light loss factor PS = Program start RCR = Room cavity ratio THD = Total harmonic distortion Numbering logic FH 4 W 5 D WW 6 Lamp qty in a luminaire cross-section 54 UNV P6 Lamp/type Voltage Ballast See previous See previous page page Luminaire type Luminaire length Body style Width Type Lens/shielding FH = TriLyte 4 = 4' 5 = 23" D = Downlight VA = Prismatic Lens 6 = 6 Lamps VA with Wireguard 28 = T5 28W 120 = 120V VI = Prismatic Lens VI with Wireguard 32 = T8 32W 277 = 277V 54 = T5HO 54W UNV= 120-277V W = Flat Design White Reflector C = Contoured Specular Reflector Options WW = Wireguard, White with No Lens XX = No Shielding Comprehensive lighting catalog 7th Edition 4.179 Linear recessed and surface lighting – Professional Smart TriLyte Low / high bay including lamps, ballast and sensor with a 3 year warranty The Smart TriLyte is the first and only packaged fluorescent low/high bay engineered specifically to correctly address sensor applications lamp cycling in Canada. It delivers optimal performance and is the only occupancy-sensored linear fluorescent low/high bay that carries a complete system warranty on all components including lamps, ballast, sensor and luminaire for 3 years. Features • Complete system intetegrating motion sensor and Philips lamps, ballast, and lighting fixture • Lamps: Low Mercury Philips Alto II T8 lamps (Philips F32T8/TL841/Alto II, 4100K, 2850 initial lumens) or Alto T5HO lamps (Philips F54T5/841/ HO/ALTO, 4100K, 5000 initial lumens) showing 95% lumen maintenance and reduced lamp-end blackening. For other lamp colour temperatures, consult your Philips Lightolier representative FH4C4DXX454UNVSML 17" (432mm) 2 ¾" (70mm) 13 ⅜" (340mm) 17 "" 17 (432mm) (432mm) • 4 models (Narrow-body) – Available in 4' and 8' lengths 36" 36" (914mm) (914mm) • 6 models (Wide-body) – Available in 4' length only. • Sensor: LampMaximizer optimizes lamp life and energy costs while reducing maintenance costs. Circular detection with passive infrared for 30-40 ft diameter coverage. Green LED on the sensor will blink constantly for 31 days once 70% of the projected lamp life has been reached • Ballast: Philips Advance programmed start electronic ballast. Total Harmonic Distorsion of <10% • Rated for ballast case temperature up to 90°C. Tested to operate at ambient temperatures of 55°C (6-lamp version without lens). For lens applications, consult your Philips Lightolier representative Narrow Body, 4-Lamp T5HO RCP C.U. 1 96 2 88 3 82 4 76 5 70 6 66 7 60 8 56 9 52 10 48 49 ½" ½" 49 (1257mm) (1257mm) ¾" 88 ¾" (222mm) (222mm) Efficiency 86.2% Spacing ratio 1.2 Electronic ballast 60˚ 3000 Input watts (120V) 234W Ballast factor 1.0 6000 9000 30˚ Application data* Luminaire spacing FC W/Sq Ft 100' x 12' x 28' Space 20' on center 17/10 0.98 100' x 12' x 28' Space 15' on center 23/14 1.37 * Average footcandles maintained. Total LLF = 0.84. Reflectance: 50% Ceiling, 30% Wall, 20% Floor. 54W T5HO lamp rated at 4400 lumens at 25°C. 4 pi x4' grid at floor level. Narrow-Body 4' 4' Narrow-Body ** Footcandles at the floor (horizontal) with Footcandles on the walls (vertical). 17 "" 17 (432mm) (432mm) • Guarantee: 3-year guarantee on all components including lamps, ballasts, sensor and any other component installed on the product by the factory. Properly installed product that Philips Lightolier determines to be defective will be repaired or replaced at Philips Lightolier’s discretion. (The warranty covers the repair or replacement of the product and does not extend to transportation, installation or replacement charges. No other warranty, either expressed or implied, beyond this statement is included. Consult your Philips Lightolier representative for further information.) Candlepower Curve Reference data Ordering information T8 Type* 36" 36" (914mm) (914mm) Lamp qty/type Lamp/luminaire nominal length 4-T8 6-T8 48" 48" Lumin. Catalog Width number 17" 23" FH4C4DXX432UNVSML FH4C5DXX632UNVSML * No shielding (accessories ordered separately). 98 98 ¼" ¼" (2496mm) (2496mm) • Body: One-piece post-painted housing providing clean, smooth, installation-friendly corners • Reflector: Contoured Miro IV reflector offers optimum performance and 95% reflectivity 36" 36" (914mm) (914mm) • Mounting: Choice of stem, surface or chain mounting. 12' to 45' mounting height with suitable lamp reflector lens mix • Bulk Pack: Sold in bulk pack only Options & accessories Wireguard/lens: See besides. ¾" 88 ¾" (222mm) (222mm) Narrow-Body 8' 8' Narrow-Body Emergency/wiring options: For special wiring, fusing, electronic dimming ballasts, consult factory. Fusing: Suffix: A (Internal fast-blow fusing). Suffix: C (Internal slow-blow fusing). Stem and canopy sets: 4 stems required per luminaire. Order catalog no. STKF12 (12"), STKF18 (18"), STKF24 (24"), STKF36 (36"), STKF48 (48"). Chain hanger kit: 2 kits per luminaire. Order catalog no. EE9HC. XX = Version without lens shielding. 4.180 Philips Lightolier White hinged 9-gauge wireguard adding rigidity to luminaire available as an accessory. (FH4WG4 for narrow luminaire and FH4WG5 for wide luminaire. Add VA or VI for a wire guard with lens.) VA = Pattern 12 prismatic lens made of virgin acrylic (.095" nominal). Complete with hinged white wireguard. VI = Pattern 12 prismatic lens made of virgin acrylic (.125" nominal). Complete with hinged white wireguard. For complete specification information visit www.lightolier.com Professional – Linear recessed and surface lighting Smart TriLyte Low / high bay including lamps, ballast and sensor with a 3 year warranty The Smart TriLyte is the first and only packaged fluorescent low/high bay engineered specifically to correctly address sensor applications lamp cycling in Canada. It delivers optimal performance and is the only occupancy-sensored linear fluorescent low/high bay that carries a complete system warranty on all components including lamps, ballast, sensor and luminaire for 3 years. FH4C5DXX654UNVSML 23 ⅛" (587mm) Wide Body, 6-Lamp T5HO RCP C.U. 1 100 2 92 3 85 2 ¾" (70mm) 19 ⅝" (498mm) 23 ⅛" (587mm) 36" (914mm) 4 79 5 72 6 67 7 62 8 58 9 53 10 49 49 ½" (1257mm) Candlepower Curve Reference data Efficiency 90.0% Spacing ratio 1.2 60˚ 3000 Electronic ballast Input watts (120V) 358.0W Ballast factor 1.0 6000 9000 30˚ Application data* Luminaire spacing FC W/Sq Ft 100' x 12' x 28' Space 20' on center 24/16 100' x 12' x 28' Space 15' on center 32/22 2.09 1.49 * Average footcandles maintained. Total LLF = 0.84. Reflectance: 50% Ceiling, 30% Wall, 20% Floor. 54W T5HO lamp rated at 4400 lumens at 25°C. 4 pi x4' grid at floor level. 15" (381mm) ** Footcandles at the floor (horizontal) with Footcandles on the walls (vertical). Ordering information T8 Type* Lamp qty/type Lamp/luminaire nominal length Luminaire width 4-T5HO 6-T5HO 48" 48" 17" 23" Catalog number FH4C4DXX454UNVSML FH4C5DXX654UNVSML * No shielding (accessories ordered separately). Numbering logic FH Luminaire type 4 Luminaire length C Reflector type 4 Width D Type XX Shielding/cord 4 Lamp qty in a luminaire cross-section riLyte 4 = 4' C= C ontoured 4 = 17" D = Downlight XX = No Shielding 4 = 4 Lamps FH = T Miro IV (4-lamp only) Series (4 & 6 Lamp X3 = No shielding, 6 = 6 Lamps 8 = 8' 5 = 23" 3' cord, twist lock (4 Lamp only) (6-lamp only; plug (single switching) 4' unit only) X6 = No shielding, 6' cord, twist lock plug (single switching for 4 lamps or less; double switching for 6 lamps) 32 UNV SML Lamp/Type Voltage Ballast 32 = T8 32W 120 = 120V SML = Smart Lighting (Philips Alto or Alto II 54 = T5HO 54W 277 = 277V 841 lamps, Philips UNV= 120-277V Advance elect. P.S. ballast and LampMaximizer sensor.) Bulk Pack. X7 = No shielding, 6' cord, no plug (double switching) Comprehensive lighting catalog 7th Edition 4.181 Linear recessed and surface lighting – Professional TriLyte Nordik Fluorescent high bay for cold environments The TriLyte Nordik is designed to achieve the same level output at -18°C as a regular fluorescent high bay at 25°C ambient temperature. With the TriLyte Nordik, you benefit of the energy savings, high color rendering and very low lumen depreciation that were reserved to standard ambient temperature, making it perfect for applications such as cold storage. Features • The Trilyte Nordik is designed for refrigerated environments • Candlelight relative output 86.2% at -18°C when ordered with Philips Lightolier supplied amalgam lamps (CRI of 4100K) FHC4C4DGI454UNVPV6 17" (431mm) 2 ¾" (70mm) • ldeal for temperatures between -18°C and 5°C when ordered with Philips Lightolier recommended T5HO amalgam lamps.For ambient temperatures of 5°C to 55°C, use regular TriLyte • Body: One-piece post painted steel housing for superior strength and able to withstand the harshest environments. Smooth and installation-friendly corners • Shielding: Full gasket sealed Door frame standard with clear acrylic lens (0.12" nominal thickness) and spring latch design for easy tool less access to the lamp compartment . Polycarbonate lens also available. Wireguard N/A 36" (914mm) • Reflector: Contoured Miro IV reflector offers optimum performance and 95% reflectivity Narrow Body RCP C.U. 1 96 2 88 3 82 4 76 5 70 6 66 7 60 8 56 9 52 10 48 • Mounting: Surface or chain Candlepower Curve Reference data Efficiency 86.2% Spacing ratio 1.2 Electronic ballast 60˚ 3000 Input watts (120V) 234W Ballast factor 1.0 6000 9000 30˚ Application data* Luminaire spacing FC W/Sq Ft 300' x 400' x 25' Space 17' on center 50 0.81 120' x 80' x 28' Space 16' on center 55 0.98 300' x 400' x 25' Space 14' on center 75 1.15 * Average footcandles maintained. Total LLF = 0.84. Reflectance: 80% Ceiling, 50% Wall, 20% Floor. Lamps rated at 4400 lumens. Options & accessories Ballast: Specify voltage (120, 277 or UNV, 347) and add suffix, e.g. UNVPV. 49 ⅜" (1255mm) Ballast type <10THD Elect. P.S. T5HO, (2) 2-Lamp PG Elect. P.S. T5HO, (1) 4-Lamp PV Elect. P.S. T5HO, (1) 4-Lamp & (1) 2-Lamp P6 Elect. P.S. T5HO, (2) 3-Lamp P7 one 4-Lamp for 1, 2, 5, & 6 and one 2-Lamp for 3 & 4 one 3-Lamp for 1, 3, & 5 and one 3-Lamp for 2, 4, & 6 Ordering information Type* Size Lamp qty/type Catalog no. Clear Acrylic Lens with Lamps 17" x 49 ⅜" 4-T5HO FHC4C4DGI454UNVPV6 * No shielding (accessories ordered separately). Emergency/wiring options: For special wiring, fusing, electronic dimming ballasts, consult factory. Emergency pack N/A. Fusing: Suffix: A (Internal fast-blow fusing). Suffix: C (Internal slow-blow fusing). Chain hanger kit: 24" chain suspension kit. 2 kits required per luminaire. Order catalog no. EE9HC. Lamps: Philips Lightolier strongly recommends purchasing the fixture complete with special amalgam lamps to insure maximum light output. Suffix: 6. Example FHC4C4DGI454 Basic catalog no. TriLyte Nordik UNV PV 6 Voltage Ballast Options 120 = 120V See page 4.182 See page 4.182 277 = 277V Add appropriate suffix. UNV= 120-277V to Catalog number. 6 = A malgam lamps (recommended). Shielding: For clear polycarbonate lens instead of clear arylic lens, replace GI by PX. Spring latch design for easy, toolless access to the lamp compartment. 4.182 Philips Lightolier For complete specification information visit www.lightolier.com Professional – Linear recessed and surface lighting TriLyte Nordik Fluorescent high bay for cold environments The TriLyte Nordik is designed to achieve the same level output at -18°C than a regular fluorescent high bay at 25°C ambient temperature. With the TriLyte Nordik, you benefit from energy savings, high color rendering and very low lumen depreciation that were reserved for standard ambient temperature, making it perfect for applications such as cold storage. FHC4C5DGI654UNVP66 Wide Body 23 ⅛" (588mm) 2 ¾" (70mm) 36" (914mm) RCP C.U. 1 100 2 92 3 85 4 79 5 72 6 67 7 62 8 58 9 53 10 49 Candlepower Curve Reference data Efficiency 90.0% Spacing ratio 1.2 Electronic ballast 60˚ 4000 Input watts (120V) 358.0W Ballast factor 1.00 8000 12000 30˚ Application data* Luminaire spacing FC W/Sq Ft 120' x 80' x 28' Space 240' on center 80 1.5 120' x 80' x 28' Space 20' on center 50 1.9 300' x 400' x 25' Space 18' on center 75 1.1 300' x 400' x 25' Space** 22' on center 50 0.76 * Average footcandles maintained. Total LLF = 0.84. Reflectance: 80% Ceiling, 50% Wall, 20% Floor. Lamps rated at 4400 lumens. 49 ⅜" (1254mm) **Idem with 30% wall reflectance. Ordering information Type* Size Lamp qty/type Catalog no. Clear Acrylic Lens with Lamps 23" x 49 ⅜" 6-T5HO FHC4C5DGI654UNVP66 * No shielding (accessories ordered separately). Example FHC4C5DGI454 Basic catalog no. TriLyte Nordik UNV P6 Voltage Ballast 120 = 120V See previous page 277 = 277V UNV= 120-277V 6 Options See previous page Add appropriate suffix. to Catalog number. 6 = A malgam lamps (recommended). Comprehensive lighting catalog 7th Edition 4.183 Linear recessed and surface lighting – Professional Gymlyter Resistant high bay dedicated to gymnasiums Gymlyter is a one-piece body made of 22-gauge steel and a strong wireguard, with or without lens, fully dedicated to gymnasiums and other recreative environments. FH4W4DWW454UNVCV 17" (432mm) 13 ⅜" (340mm) Features 2 ¾" (70mm) • Flat white reflector and wireguard as standard. (Choice of Miro IV flat reflector also availalble) Narrow Body, 6-Lamp T5HO RCP C.U. 1 96 2 88 3 82 4 76 5 70 • Side-mounted ballast for low 2-3/4" profile 6 66 • 2-, 3-, 4- and 8-lamp (4-lamp in tandem) T8 or T5HO (cross-section view) 7 60 8 56 • Sturdy one-piece post-painted housing providing clean, smooth, installation-friendly corners • Available in 4' and 8' lengths 36" (914mm) • Choice of stem, surface or chain mounting with installation up to 45' Candlepower Curve Reference data Efficiency 86.2% Spacing ratio 1.2 Electronic ballast 60˚ 3000 Input watts (120V) 234W Ballast factor 1.0 6000 9000 9 52 Application data* 10 48 30˚ Luminaire spacing FC W/Sq Ft • Accepts emergency battery packs 300' x 400' x 25' Space 17' on center 50 120' x 80' x 28' Space 16' on center 55 1.0 Options & accessories 300' x 400' x 25' Space 14' on center 75 1.2 Ballast: Specify voltage (120, 277 or UNV, 347) and add suffix, e.g. UNVPV. 49 ½" (1257mm) Ballast type <10THD Elect. I.S. T8, 4 LPB H4 Elect. I.S. T8, (1) 4 LPB & (1) 2 LPB H5 Elect. I.S. T8, (2) 4 LPB H7 Elect. P.R.S. T5/T5HO, 1 or 2 LPB PG Elect. P.R.S. T5/T5HO, 1 or 3 LPB PU Elect. P.R.S. T5/T5HO, 1 or 4 LPB PV Elect. P.S. T5/T5HO, (1) 4 LPB & (1) 2 LPB P6 Elect. P.S. T5/T5HO, (1) 3 LPB & (1) 3 LPB P7 Elect. P.S. T5/T5HO, (2) 4 LPB P8 one for outside and one for inside lamps 8 ¾" (222mm) 17" (432mm) * Average footcandles maintained. Total LLF = 0.84. Reflectance = 80% Ceiling, 50% Wall, 20% Floor. 54W T5HO lamp rated at 4400 lumens at 25°C. Narrow Body 4' White hinged 9-gauge wireguard adding rigidity to luminaire available as an accessory. one 4 LPB for outside lamps and one 2 LPB for inside lamps 36" (914mm) one 3 LPB for lamps 1, 3, & 5 and one 3 LPB for lamps 2, 4, & 6 one for outside and one for inside lamps 0.8 FH4WG4 for narrow luminaire. Add VA or VI for a wire guard with lens. LPB = Number of lamps per ballast Emergency/wiring options: For special wiring, fusing, electronic dimming ballasts, consult factory. Fusing: Suffix: A (Internal fast-blow fusing). Suffix: C (Internal slow-blow fusing). 98 ¼" (2496mm) Lamps: not included except upon request. For T5HO lamps (8/41K) installed, CFI choice of brand, add suffix 6. Consult your Philips Lightolier representative for additional options. VI Pattern 12 prismatic lens made of virgin acrylic (.125" nominal). Complete with hinged white wireguard. 36" (914mm) 4.184 Philips Lightolier 8 ¾" (222mm) 17" (432mm) Narrow Body 8' For complete specification information visit www.lightolier.com Professional – Linear recessed and surface lighting Gymlyter Resistant high bay dedicated to gymnasiums Gymlyter is a one-piece body made of 22-gauge steel and a strong wireguard, with or without lens, fully dedicated to gymnasiums and other recreative environments. Ordering information for T5 Length Lamp qty/type Lamp/luminaire nominal length Catalog no. Prismatic Lens with Wireguard 17" 4-T5HO 6-T5HO 8-T5HO 48" 96" tandem 96" tandem FH4W4DVI454 FH8W4DVI354 FH8W4DVI454 White Wireguard with No Lens 17" 4-T5HO 6-T5HO 8-T5HO 48" 96" tandem 96" tandem FH4W4DWW454 FH8W4DWW354 FH8W4DWW454 Length Lamp qty/type Lamp/luminaire nominal length Catalog no. 17" 2-T8 3-T8 4-T8 6-T8 8-T8 48" 48" 48" 96" tandem 96" tandem FH4W4DVI232 FH4W4DVI332 FH4W4DVI432 FH8W4DVI332 FH8W4DVI432 17" 2-T8 3-T8 4-T8 6-T8 8-T8 48" 48" 48" 96" tandem 96" tandem FH4W4DWW232 FH4W4DWW332 FH4W4DWW432 FH8W4DWW332 FH8W4DWW432 Type Ordering information for T8 Type Prismatic Lens (VI) with Wireguard White Wireguard with No Lens Numbering logic FH 4 W 4 D WW Lumin. Type Lumin. Length Reflector type FH 4 = 4 ' W= F lat Design 4 = 17" D = Downlight VI = Prismatic Lens VI with White Wireguard Reflector 8 = 8 ' S= F lat Design Specular Reflector Width Type Lens/shielding 4 UNV PV Lamp/type Voltage Ballast Options 2 = 2 Lamps 28 = T5 28W 120 = 120V 32 = T8 32W 277 = 277V See prev. page See previous page 3 = 3 Lamps 4 = 4 Lamps 54 = T5HO 54W UNV= 120-277V Lamp qty in a luminaire cross-section WW= Wireguard, White with 8 = 4 Lamps in tandem No Lens (8 total) 54 6 Add appropriate suffix to Catalog number Comprehensive lighting catalog 7th Edition 4.185 Linear recessed and surface lighting – Professional Cleanguard Class 10,000 CleanRoom 2' x 4' & 2' x 2' Recessed fluorescent luminaire CXS2GFSVI332UNVH3 Features Electronic ballast • UL and ULc Listed for wet or damp locations for covered ceiling use. • Fits 15/16" to 1" wide face grid ceiling systems or flanged for drywall type ceilings. Contractor responsible for sealing fixture to ceiling. • Hemmed over side rails for maximum safety. • Spring loaded rooster head latches. • 18 gauge steel hinges. • Flat and regressed aluminum doors available. Options & accessories Ballast type <10THD <20THD Electronic T8 HI*, P2** 1-3 Lamp Elec T8 H3*, P3** 03* 1-4 Lamp Elect T8 H4*, P4** 04* 1-3 Lamp TT5 40 Watt IB*, PR** SB* Electronic TT5 40 Watt I3* X3* 1500 Ordering information Size Lamp qty–type Exposed T-Grid Flanged for dry wall or plaster 2' x 4' 2 T8 3-T8 4-T8 CXS2GFAVI232 CXS2GFAVI332 CXS2GFAVI432 CXS2FFAVI232 CXS2FFAVI332 CXS2FFAVI432 Flat Steel Door 2' x 4' 2 T8 3-T8 4-T8 CXS2GFSVI232 CXS2GFSVI332 CXS2GFSVI432 CXS2FFSVI232 CXS2FFSVI332 CXS2FFSVI432 Regressed Aluminum Door 2' x 4' 2 T8 3-T8 4-T8 CXS2GRAVI232 CXS2GRAVI332 CXS2GRAVI432 CXS2FRAVI232 CXS2FRAVI332 CXS2FRAVI432 Example CXS2GFSVI332 Cleanguard Wet location Class 10,000 or 100,000 Clean Room S0* 2250 30˚ Plaster frame: For F type troffers, order plaster frames separately. Catalog no.: PF24 for 2'x4' troffer; PF22 for 2'x2' troffer. Fusing: Suffix: A (Internal fast-blow fusing). Suffix: C (Internal slow-blow fusing). H3 A Voltage Ballast Options 120 = 120V See page 4.186 See page 4.186 277 = 277V and page 4.130 UNV= 120-277V (Elec. T8 Ballast only) Candlepower Curve Reference data 5" (127mm) Efficiency 63.1% Spacing ratio 1.2 Electronic ballast Electrical/wiring options: For special wiring, fusing, electronic dimming ballasts, consult factory. Continuous row installation: For F type fixtures, half-width flanges are required between fixtures. Catalog no.: 2FCTrim for each joint. UNV CXS2GFSVI26UUNVHI * Instant start ** Program start 500 60˚ Input watts (120V) 53.7W LER FL 56.0 24" (610mm) 1000 Ordering information Exposed T-Grid Flanged for dry wall or plaster 2-6" T8 3-TT5 3-1.6"U T8 CXS2GFAVI26U CXS2GFAVI3FT CXS2GFAVI32U CXS2FFAVI26U CXS2FFAVI3FT CXS2FFAVI32U 2' x 2' 2-6" T8 3-TT5 3-1.6"U T8 CXS2GFSVI26U CXS2GFSVI3FT CXS2GFSVI32U CXS2FFSVI26U CXS2FFSVI3FT CXS2FFSVI32U 2' x 2' 2-6" T8 3-TT5 3-1.6"U T8 CXS2GRAVI26U CXS2GRAVI3FT CXS2GRAVI32U CXS2FRAVI26U CXS2FRAVI3FT CXS2FRAVI32U Type Size Flat Aluminum Door 2' x 2' Flat Steel Door Regressed Aluminum Door Example Lamp qty–type CXS2GFSVI26U Cleanguard Wet location Class 10,000 or 100,000 Clean Room Philips Lightolier 60˚ page 4.130 Ballast: Specify voltage (120, 277 or UNV) and type and add as suffix, e.g. UNVHI 4.186 750 Input watts (120V) 108.7W LER FL 73.2 24" (610mm) • Full perimeter gasketing (closed cell Neoprene) between Type Door frame and lens, between housing and Door frame. Flat Aluminum • Ends sealed to body. Door • .125 pattern 12 lens installed smooth side down. • Door frame is post painted, baked acrylic enamel. Efficiency 67.9% Spacing ratio 1.2 5" (127mm) • Meets requirements for Federal Standard 209E Class 10,000 & 100,000 Clean Room tested by Independent Lab. Candlepower Curve Reference data UNV HI 1500 30˚ A Voltage Ballast Options 120 = 120V See page 4.186 See page 4.186 277 = 277V and page 4.130 UNV= 120-277V (Elec. T8 or TT5 Ballast only) For complete specification information visit www.lightolier.com Professional – Linear recessed and surface lighting Cleanguard Class 1,000/10,000 CleanRoom 2' x 4' & 2' x 2' Recessed fluorescent luminaire 2' x 2', 2' x 4' - 1½" wide T-bar CXS2WFAVI26UUNVHI Candlepower Curve Reference data 5" (127mm) Features Efficiency 63.1% Spacing ratio 1.2 Electronic ballast 500 60˚ Input watts (120V) 53.7W LER FL 56.0 24" (610mm) • UL and ULc Listed for wet or damp locations for covered ceiling use. 1000 Ordering information Type Flat Aluminum Door Example Size Lamp qty–type 2' x 2' CXS2WFAVI26U 2-6" T8 CXS2WFAVI3FT 3-TT5 3-1.6" U T8 CXS2WFAVI32U CXS2WFAVI26U Cleanguard Wet location Class 1,000, 10,000 or 100,000 Clean Room ¹5⁄¹6" to 1 ½" Wide face T-Grid UNV 1500 • Fits 15/16" to 1 1/2" wide face grid ceiling systems. Contractor responsible for sealing fixture to ceiling. 30˚ • .125 pattern 12 lens installed smooth side down. • Door frame is post painted, baked acrylic enamel. A • Hemmed over side rails for maximum safety. Ballast Options See page 4.187 See page 4.187 and page 4.130 • Spring loaded rooster head latches. • 18 gauge steel hinges. • Flat extruded aluminum door. (Elec. T8 or TT5 Ballast only) CXS2WFAVI332UNVH3 Options & accessories Candlepower Curve Reference data 5" (127mm) Efficiency 67.9% Spacing ratio 1.2 Electronic ballast 750 60˚ Input watts (120V) 108.7W LER FL 73.2 24" (610mm) 1500 Ordering information Type Flat Aluminum Door Example Size Lamp qty–type ¹5⁄¹6" to 1 ½" Wide face T-Grid 2' x 2' 2-T8 3-T8 4-T8 CXS2WFAVI232 CXS2WFAVI332 CXS2WFAVI432 CXS2WFAVI332 Cleanguard Wet location Class 1,000, 10,000 or 100,000 Clean Room UNV • Full perimeter gasketing (closed cell Neoprene) between Door frame and lens, closed cell ethafoam gasketing between housing and Door frame. • Ends sealed to body. HI Voltage 120 = 120V 277 = 277V UNV= 120-277V • Meets requirements for Federal Standard 209E Class 1,000/10,000 & 100,000 Clean Room tested by Independent Lab. 2250 30˚ page 4.130 Ballast: Specify voltage (120, 277 or UNV) and type and add as suffix, e.g. UNVHI Ballast type <10THD <20THD Electronic T8 HI*, P2** 1-3 Lamp Elec T8 H3*, P3** 03* 1-4 Lamp Elect T8 H4*, P4** 04* 1-3 Lamp TT5 40 Watt IB*, PR** SB* Electronic TT5 40 Watt I3* X3* S0* * Instant start ** Program start Electrical/wiring options: For special wiring, fusing, electronic dimming ballasts, consult factory. H3 A Fusing: Suffix: A (Internal fast-blow fusing). Suffix: C (Internal slow-blow fusing). Voltage Ballast Options 120 = 120V See page 4.187 See page 4.187 277 = 277V and page 4.130 UNV= 120-277V (Elec. T8 Ballast only) Mounting Methods Exposed T-grid ceiling, 1 ½" face, (with flat aluminum frame). Exposed T-grid ceiling 15⁄16" to 1" face (with flat aluminum frame). ¼" max. ¼" max. 1 ½" max. gasketing gasketing gasketing 1 ½" 24" 1 ½" max. gasketing 24" ¹5⁄¹6" or 1" Comprehensive lighting catalog 7th Edition 4.187 Linear recessed and surface lighting – Professional Hazardline Vapor/dust/wet locations enclosed luminaire This luminaire is suitable for indoor and outdoor application in three areas. Class I Div. 2 locations are those in which flammable gases, vapors or liquids are handled in closed containers from which any escape of hazardous materials are accidental. Class II locations are hazardous because of the presence of combustible dust. Class III locations are hazardous because of the presence of easily ignitable fibers of flyings. Hazardline, additionally has a wet location rating for use indoors. Features • Same fixture meets Class I, II, III and Wet Location requirements. • UL-Listed Class I, Division 2, Groups A, B, C and D locations. HSCXT232120SO • UL-Listed Class II, Division 1 and 2, Groups F and G and Class III, Division 1 and 2 locations. • UL Listed for wet locations. • Non-corrosive fiberglass reinforced polyester composite body suitable (T8 or T12RS) for 40°C ambient temperature. Efficiency 72.7% Spacing ratio 1.0 8 932" (210mm) Electronic ballast 7 516" (186mm) 1000 5 932" (134mm) • Meets UL 746C impact test requirements. • Meets UL 94-5VA fire rating. • Stainless steel, 16 gauge steel door with 3/16" tempered glass lens. 8 932" (210mm) • Stainless spring steel toggle clamps to secure lens door frame. Coefficients of utilization % wall reflectance 7 516" (186mm) 9 ¾" (247mm) • One-piece silicone gasketing. Room Cavity Ratio page 4.217 Ballast: S pecify voltage (120, 277) and type and add as suffix, e.g. HSCXT232UNVHI Ballast type <10THD <20THD 30˚ Application data* Luminaire spacing FC W/Sq Ft 1 78 75 72 50' x 70' x 12' Space 8' x 8' (64 sq ft/fixture) 51 0.9 12' x 16' x 8.5' Space 6' x 8' (48 sq ft/fixture) 54 1.2 8' x 8' x 8.5' Cubicle/60" Partition 54 30' x 30' (64 sq ft/fixture) 0.9 3 66 59 54 4 60 53 47 5 55 46 40 6 51 42 35 7 47 37 31 8 43 33 27 1-2 Lamp Elec T8 HI* S0* 9 39 30 24 1-3 Lamp Elec T8 H3* 03* 10 36 27 21 * Instant start 1500 70 50 30 2 72 67 62 Options & accessories 60˚ 500 Input watts (120V) 62.0W Ballast factor 0.88 9 ¾" (247mm) • Meets UL 844 static discharge requirements. Candlepower Curve Reference data 5 932" (134mm) * Average footcandles maintained Total LLF=.75 Reflectance: 80% Ceiling, 50% Wall, 20% Floor RE835 lamp rated at 3000 lumens 20% of floor and 80% of ceiling effective cavity reflectance Electrical/wiring options: For special wiring, fusing, consult factory. Ordering information Type Class/division Enclosed Industrial Fluorescent Vapor-tight Class I Division 2 Dust-tight Class II/III Division 1 Division 2 Wet-Location Fixture length Lamp Catalog no. qty/type 53" 2-T8 HSCXT232 53" 3-T8 HSCXT332 *800 MA HO fixtures are standard with -20°F ballasts *Consult factory for HO units. Example HSCXT232 Hazardline Vapor/Dust/Wet Locations Enclosed Luminaire 4.188 Philips Lightolier 120 SO Voltage Ballast Options 120 = 120V See page 4.188 See page 4.188 277 = 277V and page 4.217 UNV= 120-277V For complete specification information visit www.lightolier.com Professional – Linear recessed and surface lighting Hazardline Vapor/dust/wet locations enclosed luminaire This luminaire is suitable for indoor and outdoor application in three areas. Class I Div. 2 locations are those in which flammable gases, vapors or liquids are handled in closed containers from which any escape of hazardous materials are accidental. Class II locations are hazardous because of the presence of combustible dust. Class III locations are hazardous because of the presence of easily ignitable fibers of flyings. Hazardline, additionally has a wet location rating for use indoors. Features The following hazardous location definitions are excerpted from Article 500 of the 1990 National Electrical Code Thermal Performance of HSCXT Fixtures* HSCXT Series meets the following classifications Ordering information Lamp qty/type Ambient temp. °C “T” Numbers Fixture Temp.* Catalog no. 2-T8 3-T8 40 40 T-4A T-4A 120°C (248°F) 120°C (248°F) HSCXT232 HSCXT332 *800 MA HO fixtures are standard with -20°F ballasts *Consult factory for HO units. Class I, Division 2 locations (a) Class I, Division 2 location is a location (1) in which volatile flammable liquids or flammable gases are handled, processed, or used, but in which the liquids, vapors, or gases will normally be confined within closed containers or closed systems from which they can escape only in case of accidental rupture or breakdown of such containers or systems, or in case of abnormal operation of equipment. Class II locations Class II locations are those that are hazardous because of the presence of combustible dust. Features (a) Class II, Division 1. A Class II, Division 1 location is a location: (1) which combustible dust is in the air under normal operating conditions, in quantities sufficient to produce explosive or ignitible mixtures; or (2) where mechanical failure or abnormal operation of machinery or equipment might cause such explosive or ignitible mixtures to be produced, and might also provide a source of ignition through simultaneous failure of electric equipment, operation of protection devices, or from other causes; or (3) in which combustible dusts of an electrically conductive nature may be present in hazardous quantities. Hi-temp power channel Heavy-duty hinged stainless steel door (b) Class II, Division 2. A Class II, Division 2 location is a location where combustible dust is not normally in the air in quantities sufficient to produce explosive or ignitible mixtures, and dust accumulations are normally insufficient to interfere with the normal operation of electrical equipment or other apparatus, but combustible dust may be in suspension in the air as a result of infrequent malfunctioning of handling or processing equipment and where combustible dust accumulations on, in, or in the vicinity of the electrical equipment may be sufficient to interfere with the safe dissipation of heat from electrical equipment or may be ignitible by abnormal operation or failure of electrical equipment. Top/end suspension hubs Class I/Division 2 construction Class III locations Class III locations are those that are hazardous because of the presence of easily ignitible fibers of flyings, but in which such fibers or flyings are not likely to be in suspension in the air in quantities sufficient to produce ignitible mixtures. Options (a) Class III, Division 1. A Class III, Division 1 location is a location in which easily ignitible fibers or materials producing combustible flyings are handled, manufactured, or used. (b) Class III, Division 2. A Class III, Division 2 location is a location in which easily ignitible fibers are stored or handled. 45° Adjustable quadrant brackets NKH45 Top-mount angle-bars HACM CSP Comprehensive lighting catalog 7th Edition 4.189 Linear recessed and surface lighting – Professional Sealatron Wet location enclosed industrial luminaire The Sealatron is an enclosed industrial luminaire rated for wet locations with an IP67 rating ST4WA232120SO Hole each end .88" Dia. (⅞") Hole each end .88" Dia. (⅞") 1 ½" (38mm) 5 316" (132mm) 2 ⅛" (154mm) 3 316" (81mm) Features 5 ⅞" (149mm) 3 316" (81mm) Two Top Mounting Brackets: STW TOP BRKT 6 ⅝" (168mm) 7" (178mm) 7" (178mm) • NSF Certified for Non-Food Zone installations. Stud location (2 places) Drill Point location (2 places) • IP67 rating. Two Surface or Chain Mounting Brackets: STW END BRKTS 3" (76mm) 6 ⅝" (168mm) • Wet Location-Areas of high humidity, water vapor, rain, incidental water spray, or other non-corrosive or nonflammable liquid. (UL-Listed) 1 ½" (38mm) • Acceptable for outdoor as well as indoor installations. • One-piece impact resistant, non-conductive, noncorrosive housing, reinforced polyester fiberglass housing. 14 ¾" (375mm) ¼" - 28 Brass Studs 17 ½" (445mm) 25 1316" (655mm) Drill Point location (2 places) • Smooth exterior surface for easy cleaning. Stud location (2 places) • Lighting channel has high reflectance baked white enamel finish. • Two gasketed threaded (1/2" trade size) wet location hubs installed on ends. • High impact DR acrylic molded lens. • Crepe pattern inner surface lens. • Continuous, compressible, closed-cell neoprene gasket bonded to housing. 38 ¾" (984mm) Drill Point Location (2 places) 41 ⅞" (1064mm) 49 1316" (127mm) Stud location (4 places) • ABS lock-tight plastic molded cam-action tension latches. • K.O.'s provided throughout for easy access. 40 1316" (1037mm) ¼" - 28 Brass Studs • Can be surface (wall/ceiling) or suspended mounted unless otherwise specified. 89 ⅞" (2283mm) 97 1316" (2484mm) • Mounting brackets available, Order separately. Ordering information Options & accessories Ballast: Specify voltage (120, 277 or UNV) and type and add as suffix, e.g. ST4WA232UNVHI Electronic T12 (HO only) Ballast type Type SS <10THD <20THD Electronic T8 H0 P2 SO Electronic T8 HI* SO* 1-4 Lamp Electronic T8 H4* 04* Electronic T5 Instant S (28W) PI Electronic T5 Program S PG 1-4 Lamp Electronic T5 (54W) PV * Instant start Standard Size Radio interference filter: 120 or 277 volt, 50 or 60 Hz. One per fixture. Suffix: R. One per ballast. Suffix: B. Fusing: Suffix: A (Internal fast-blow fusing). Suffix: C (Internal slow-blow fusing). Top mounting bracket: Order Catalog no.: STW TOP BRKT. Philips Lightolier Catalog no. ST4WA117 ST4WA217 Electronic ballast 1-T8 1-T5 1-T5HO 2-T8 2-T5 2-T5HO ST4WA132 ST4WA128 ST4WA154 ST4WA232 ST4WA228 ST4WA254 Ballast factor 0.88 7 x 49 ¹3⁄¹6" 48" 46" 46" 48" 46" 46" 48" 46" 46" 48" 46" 46" 96" 96" 96" 1-T8* 1-T5* 1-T5HO* 2-T8** 2-T5** 2-T5HO** 2-T8SL 2-T8HO 2-T12HO ST8WA132 ST8WA128 ST8WA154 ST8WA232 ST8WA228 ST8WA254 ST8WA259SL ST8WA286HO ST8WA296HO *2 lamps total, (in tandem) **4 lamps total, (in tandem) Example Efficiency 85.10% Spacing ratio 1.5 1-T8 1-T8 Water tight kits: One installed each end of fixture. For additional kits, order Catalog no.: STW-DC2. Electrical/wiring options: Consult factory. Lamp qty–type 24" 24" 7 x 97 ¹3⁄¹6" Candlepower Curve Reference data Lamp length 7 x 25 ¹3⁄¹6" STW Wet Location Enclosed Industrial Cold weather ballasts: T12 HO lamped fixtures are standard with –20°F ballasts. To specify cold weather (0°F) ballasts for RS or T8 fixtures. Suffix: CW. 4.190 40 1316" (1037mm) ¼" - 28 Brass Studs 5 ⅛" (130mm) ST4WA232 Sealatron Wet Location Enclosed Luminaire UNV HI I.W. (120V) 54W 500 60˚ 1000 1500 Smooth virgin acrylic lens opens easily and hinges from either side for easy maintenance. 30˚ Precision molded preformed knockouts for stem, chain or surface mounting. A Voltage Ballast Options 120 = 120V See page 4.190 See page 4.190 277 = 277V UNV= 120-277V Note: Sealatron luminaire also available in LED For complete specification information visit www.lightolier.com Professional – Linear recessed and surface lighting Sealatron IP low profile Wet location enclosed industrial luminaire The Sealatron IP Low Profile enclosed Industrial is a wet location listed luminaire that incorporates a low profile housing design, high impact lenses and IP ratings. IP4WP232UNVHI Candlepower Curve Reference data A Features Efficiency 66.9% Spacing ratio 1.3 • IP65 rating for ribbed lenses and IP67 rating for prismatic lens. Electronic ballast Input watts (120V) 55W A (Overall Length) 2' models 27 11/16" (703mm) 4' models 51 9/16" (1310mm) 8' models 100" (2540mm) 60˚ 550 • Wet Location Areas of high humidity, water vapor, rain, incidental water spray, or other non-corrosive or nonflammable liquid. 1100 2 and 3 lamp (1 lamp 8') • Also suitable for damp locations. 1 lamp (except 8') 4 ¼" (108mm) 7 ¼" (184mm) • Non-conductive, non-corrosive housing. 1650 4 ¼" (108mm) 30˚ 4 ½" (114mm) • Choice of ribbed or injection molded prismatic diffusers. • Continuous poured gasket. • Polycarbonate cam action latches are standard. 4 ¼" (108mm) 7 ¼" (184mm) • Ballast is retained by a snap-on gear tray in lieu of channel, reducing weight. 4 ¼" (108mm) • Two snap-on stainless steel mounting brackets included, can be installed anywhere along housing (except at latches). 4 ½" (114mm) Prismatic Injected Molded Lens (P) Options & accessories Ballast: Specify voltage (120, 277 or UNV) and type and add as suffix, e.g. IP4WP232UNVHI Ordering information Family Lamps X section Lamp Available fixture lenses Lamp type 2' IP 1 2 1 2 R, P 14, 17, 24HO 4' IP 1 2 3 1 2 3 R, P A, R, P A, R, P 28, 32, 54HO 28, 32, 54HO 28, 32, 54HO 1 2 3 2 4 6 A 28, 32, 54HO 28, 32, 54HO 28, 32 8' IP • Smooth exterior surface for easy cleaning. • Molded fiberglass 5V-A housing. Mounting Bracket (included) Ribbed Lenses (R, A) Size • Acceptable for outdoor as well as indoor installations. Length in. (mm) 27 11/16" (703) 51 9/16" (1310) 100" (2540) Width in. (mm) 4½" (114) 7¼" (184) 4½" (114) 7¼" (184) 7¼" (184) 7¼" (184) Height in. (mm) Ballast type 4¼" (108) Electronic T8 HI* SO* 1 - 3 Lamp Electronic T8 H3* 03* 1 - 4 Lamp Electronic T8 H4* 04* 2 - 3 Lamp Electronic T8 H6* 4¼" (108) 4¼" (108) <10THD <20THD 1 - 4 Lamp or 1 - 4 Lamp Elect T8 H5* Electronic T5 (28W/54W) PG** 1 - 3 Lamp Electronic T5 (54W) PU** * Instant start ** Program start Electrical/wiring options: For special wiring, fusing, electronic dimming options, consult factory. Fusing: Suffix: A (Internal fast-blow fusing). Suffix: C (Internal slow-blow fusing). Example IP 4 W A 2 Sealatron Fixture Fixture Lamp IP low length width Lens shielding type quantity profile 2 = 2' W = 7 ¼" R = Lineal Ribbed 1 = 1 Lamp 4 = 4' N * = 4 ½" (IP65) Polycarbonate 2 = 2 Lamps 8 = 8' A = Lineal Ribbed High 3 = 3 Lamps Impact Acrylic (IP65) (28W, 32W, 54W P = Prismatic Injection lamp types only)** Polycorbonate 32 UNV HI Lamp type/ fixture length Voltage Ballast type 14 = T5 (2') 120 = 120V See page 4.191 17 = T8 (2') 277 = 277V 24 = T5HO (2') UNV= 120-277V 28 = T5 (4') 32 = T8 (4') 54 = T5SO (4') A Options Add appropriate suffix to catalog * Narrow housing only available in one lamp, two and four foot fixture sizes. ** 28W, 32W and 54W available in three lamp, four foot fixture sizes. 28W and 32W available in three lamp, eight foot fixture sizes. Comprehensive lighting catalog 7th Edition 4.191 Linear recessed and surface lighting – Specification Cleanguard wet location Recessed fluorescent luminaire 2' x 4', 2' x 2' & 1' x 4' WES2GFAVA432UNVH4 5" (127mm) 24" (610mm) • UL and C-UL Listed for wet or damp locations for covered ceiling use. Type • 5" deep body for 2x4 and 2x2. • 81.2% efficient (T8), 2x4 4 lamp. • 69.0% efficient (T8), 2-6"U. • 64.6% efficient (T8). 1x4 2 lamp. • Hemmed over side rails for maximum safety. • Fixture ends turned-in for safe handling. 2-T8 3-T8 4-T8 WES2GRAVA232 WES2FRAVA232 WES2GRAVA332 WES2FRAVA332 WES2GRAVA432 WES2FRAVA432 Flat Aluminum Door 2-T8 3-T8 4-T8 WES2GFAVA232 WES2GFAVA332 WES2GFAVA432 Example 2' x 4' WES2GFAVA432 Cleanguard Wet Location UNV Voltage 120 = 120V 277 = 277V UNV= 120-277V WES2GFAVA26UUNVHI • 18 gauge steel hinges. 5" (127mm) Ballast type <10THD <20THD Electronic T8 HI*, P2** S0* 1-3 Lamp Elec T8 H3*, P3** 03* 1-4 Lamp Elect T8 H4*, P4** 04* I3* X3* IB*, PR** SB* * Instant start ** Program start Electrical/wiring options: For special wiring, fusing, electronic dimming ballasts, consult factory. Ordering information Plaster frame: For F type troffers, order plaster frames separately. Catalog no.: PF24 for 2'x4' troffer; PF22 for 2'x2' troffer; PF14 for 1'x4' troffer. Fusing: Suffix: A (Internal fast-blow fusing). (Elec. T8 Ballast only) Candlepower Curve Efficiency 71.6% Spacing ratio 1.3 Continuous row installation: For 1'x4' F type fixtures, trim is required between fixtures. Cat. no.: 1FCTrim For 2'x4' and 2'x2' F type fixtures, trim is required between fixture Cat. no. S2FCTrim (One per joint is required). 600 Flat Steel Door 2' x 2' 2-6" T8 3-TT5 3-1.6"U T8 WES2GFSVA26U WES2FFSVA26U WES2GFSVA3FT WES2FFSVA3FT WES2GFSVA32U WES2FFSVA32U Regressed 2' x 2' Aluminum Door 2-6" T8 3-TT5 3-1.6"U T8 WES2GRAVA26U WES2FRAVA26U WES2GRAVA3FT WES2FRAVA3FT WES2GRAVA32U WES2FRAVA32U Flat Aluminum Door 2-6" T8 3-TT5 3-1.6"U T8 WES2GFAVA26U WES2FFAVA26U WES2GFAVA3FT WES2FFAVA3FT WES2GFAVA32U WES2FFAVA32U Exposed T T-Grid WES2GFAVA26U UNV Cleanguard Wet Location 1' x 4' Candlepower Curve 600 60˚ Input watts (120V) 80.0W LER FL 48.3 1200 Lamp Exposed T qty–type T-Grid 2-T8 2-T8 2-T8 WES1GFAVA232 Cleanguard Wet Location A Electronic ballast Ordering information Flat Steel Door Regressed Alum. Door Flat Aluminum Door 30˚ Efficiency 69.0% Spacing ratio 1.3 12" (305mm) Size HI 1800 Reference data 4" (101mm) Type Flanged for Dry Wall or Plaster Voltage Ballast Options 120 = 120V See page 4.192 See page 4.192 277 = 277V and page 4.130 UNV= 120-277V WES1GFAVA232UNVHI Example 60˚ 1200 Size Suffix: C (Internal slow-blow fusing) Philips Lightolier A Type Seismic Hold-Down Clip: For 1'x4' type G, Suffix: 2HD. Factory installed. 4.192 H4 Ballast Options See page 4.192 See page 4.192 and page 4.130 Lamp qty–type Example 30˚ Input watts (120V) 56.3W LER FL 58.6 24" (610mm) 2' x 2' 60˚ WES2FFAVA232 WES2FFAVA332 WES2FFAVA432 Electronic ballast page 4.130 Ballast: Specify voltage (120, 277 or UNV) and type and add as suffix, e.g. UNVHI 3750 Reference data • Flat and regressed aluminum doors available. Electronic TT5 40 Watt WES2FFSVA232 WES2FFSVA332 WES2FFSVA432 Regressed 2' x 4' Aluminum Door • Mitered corner steel lens frame. 1-3 Lamp TT5 40 Watt Flanged for Dry Wall or Plaster WES2GFSVA232 WES2GFSVA332 WES2GFSVA432 • Slimline Door frame with 1000 square inch lens opening on 2x4 door. Options & accessories Exposed T T-Grid 2-T8 3-T8 4-T8 • Built-in earthquake clips 2x4, 2x2. • Spring loaded rooster head latches. 1250 2' x 4' • Full perimeter gasketing (closed cell Neoprene) between Flat Steel Door Door frame and lens, between housing and Door frame. • Door frame is post painted, baked acrylic enamel. Electronic ballast 2500 Lamp qty–type Size Efficiency 81.2% Spacing ratio 1.3 Input watts (120V) 108.7W LER FL 73.2 Ordering information Features Candlepower Curve Reference data Flanged for Dry Wall or Plaster WES1GFSVA232 WES1FFSVA232 WES1GRAVA232 WES1FRAVA232 WES1GFAVA232 WES1FFAVA232 UNV HI 1800 30˚ A Voltage Ballast Options 120 = 120V See page 4.192 See page 4.192 277 = 277V and page 4.130 UNV= 120-277V For complete specification information visit www.lightolier.com Specification – Linear recessed and surface lighting Cleanlite Damp/wet locations enclosed luminaire SC4WC232UNVHI Efficiency 79.3% Spacing ratio 1.6 2 1316" (71mm) 2 1316" (71mm) 6 116" (27mm) 6 116" (27mm) 8 532" (207mm) 8 532" (207mm) 6 116" (27mm) 6 116" (27mm) Candlepower Curve Reference data • UL-listed for dry and damp locations. • UL-listed for wet locations. • Silicone sealed body (SC4W). Electronic ballast Input watts (120V) 53.0W Features • For industrial or commercial applications. 500 60˚ • Crisp modular design. • Available in 4' one piece body. 2 1316" (71mm) 2 1316" (71mm) • Continuous closed-cell gasketing at all seal points. 1000 8 532" (207mm) 8 532" (207mm) • Smooth one-piece water-clear acrylic lens. • Lock-tight cam-action latches. 1500 30˚ • Water-tight hubs for electrical feed (SC4W). • Construction meets NYC code requirements. Water-tight hubs Ordering information Type Size Damp Locations Wet Locations Example 8 3⁄16" x 50 5⁄16" 8 3⁄16" x 50 5⁄16" SC4WC232 Guardsman Vandal Resistant Damp/Wet Locations Enclosed Luminaire Lamp length Lamp qty–type Options & accessories Catalog no. 48" 46" 46" 48" 46" 46" 48" 46" 46" 1-T8 1-T5 1-T5HO 2-T8 2-T5 2-T5HO 3-T8 3-T5 3-T5HO SC4DC132 SC4DC128 SC4DC154 SC4DC232 SC4DC228 SC4DC254 SC4DC332 SC4DC328 SC4DC354 48" 46" 46" 48" 46" 46" 48" 46" 46" 1-T8 1-T5 1-T5HO 2-T8 2-T5 2-T5HO 3-T8 3-T5 3-T5HO SC4WC132 SC4WC128 SC4WC154 SC4WC232 SC4WC228 SC4WC254 SC4WC332 SC4WC328 SC4WC354 UNV HI page 4.130 Ballast: Specify voltage (120, 277 or UNV) and type and add as suffix, e.g. SC4DC232UNVHI Ballast type <10THD <20THD Electronic T8 HI* SO* 1 - 3 Lamp Electronic T8 H3* 03* Electronic T5 Program S PG SO* 1 - 3 Lamp Elect T5 (54W) PU – * Instant start Standard Tamperproof latches: Suffix: TP. Optional lenses: Lexan lenses or DR acrylic lens. Consult factory. Water tight kits: All fixtures are furnished with one watertight hub kit for top or end conduit entry. Additional water tight kits required for every entry. Catalog no.: GWHB CSP. For coupling kits required for continuous row mounting. Catalog no.: KWCP CSP TP Voltage Ballast Options 120 = 120V See page 4.193 See page 4.193 277 = 277V UNV= 120-277V (Elec. T8 Ballast only) Comprehensive lighting catalog 7th Edition 4.193 Linear recessed and surface lighting – Specification Guardsman Vandal Resistant Recessed fluorescent luminaire 2' x 4', 2' x 2' & 1' x 4' GVS2GFSVL432UNVH4 5" (127mm) 24" (610mm) • Excellent for locations where vandal resistance is required. Ordering information • Prismatic lens (VL) is 3/16" thick pattern 12, minimum impact strength, 130 foot pounds. Type • Full perimeter gasketing (closed cell Neoprene) between Door frame and lens. • 5" deep body, 2x2 and 2x4. Example • 74.4% efficient (T8), 2x4 4 lamp. GVS2GFSVL432 Guardsman Vandal Resistant • Hemmed over side rails for maximum safety. • Fixture ends turned-in for safe handling. • Built-in earthquake clips on 2x2 and 2x4. • Spring loaded rooster head latches. • 18 gauge steel hinges. • 62.2% efficient (T8), 1x4 2 lamp. GVS2FFSVL232 GVS2FFSVL332 GVS2FFSVL432 UNV Electronic T8 HI*, P2** 1-3 Lamp Elec T8 H3*, P3** 03* 1-4 Lamp Elect T8 H4*, P4** 04* S0* Type Flat Steel Door I3* X3* SB* Example Candlepower Curve Efficiency 69.3% Spacing ratio 1.3 ** Program start Lens: For optional 9/64" thick (VK) pattern 12, minimum impact strength, 80 foot pounds, substitute VL with VK in Catalog no. i.e:GVS2GFSVK432. Size Exposed T-Grid Flanged for dry wall or plaster 2' x 2' 2-6" T8 3-TT5 3-1.6"U T8 GVS2GFSVL26U GVS2GFSVL3FT GVS2GFSVL32U GVS2FFSVL26U GVS2FFSVL3FT GVS2FFSVL32U GVS2GFSVL26U UNV HI Candlepower Curve Efficiency 62.3% Spacing ratio 1.3 Electronic ballast 12" (305mm) Ordering information Fusing: Suffix: A (Internal fast-blow fusing). Suffix: C (Internal slow-blow fusing). Type Size Lamp qty–type Flat Steel Door 1' x 4' 2-T8 30˚ A Reference data 4" (101mm) Plaster frame: For F type troffers, order plaster frames separately. Catalog no.: PF24 for 2'x4' troffer; PF22 for 2'x2' troffer. 1800 Voltage Ballast Options 120 = 120V See page 4.194 See page 4.194 277 = 277V and page 4.130 UNV= 120-277V GVS1GFSVL232UNVHI Example 60˚ 1200 Lamp qty–type Electrical/wiring options: For special wiring, fusing, electronic dimming ballasts, consult factory. Seismic hold-down clip: For 1'x4' type G, Suffix: 2HD. Factory installed. 600 Input watts (120V) 56.4W LER FL 58.9 Guardsman Vandal Resistant * Instant start 30˚ A Reference data Ordering information <10THD <20THD IB*, PR** H4 3750 Voltage Ballast Options 120 = 120V See page 4.194 See page 4.194 277 = 277V and page 4.130 UNV= 120-277V 24" (610mm) Ballast type 500 60˚ Input watts (120V) 80.0W LER FL 48.3 1000 GVS1GFSVL232 Guardsman Vandal Resistant Philips Lightolier GVS2GFSVL232 GVS2GFSVL332 GVS2GFSVL432 Electronic ballast page 4.130 Ballast: Specify voltage (120, 277) and type and add as suffix, e.g. UNVHI 4.194 Flanged for dry wall or plaster 5" (127mm) • Turned up edges for safe handling. Options & accessories Exposed T-Grid GVS2GFSVL26UUNVHI • 69.3% efficient (T8), 2x2 2-6"U. 60˚ 2500 2-T8 3-T8 4-T8 2' x 4' 1250 Input watts (120V) 105W LER FL 69.0 Lamp qty–type Size Flat Steel Door • Tamper resistant holt head screws secure lens to housing. 1 & 2 Lamp TT5 40 Watt Efficiency 74.4% Spacing ratio 1.3 Electronic ballast Features 1-3 Lamp TT5 40 Watt Candlepower Curve Reference data Exposed T-Grid Flanged for dry wall or plaster GVS1GFSVL232 GVS1FFSVL232 UNV HI 1500 30˚ A Voltage Ballast Options 120 = 120V See page 4.194 See page 4.194 277 = 277V and page 4.130 UNV= 120-277V For complete specification information visit www.lightolier.com Specification – Linear recessed and surface lighting Guardsman Vandal Resistant Surface box luminaire 2' x 4', 2' x 2' & 1' x 4' GVB2SFSVL432UNVH4 Candlepower Curve Reference data 5 ½" (140mm) Efficiency 65.2% Spacing ratio 1.3 Electronic ballast 1050 24" (610mm) Ordering information Type Size Flat Steel Door 2' x 4' Example 60˚ Input watts (120V) 13.3W • Excellent for locations where vandal resistance is required. 2100 Lamp qty–Type 2-T8 3-T8 4-T8 GVB2SFSVL432 Guardsman Vandal Resistant UNV • 20 gauge steel body. Surface box GVB2SFSVL232 GVB2SFSVL332 GVB2SFSVL432 H4 Features 3150 30˚ • Prismatic lens (VL) is 3/16" thick, pattern 12, minimum impact strength, 130 foot pounds. • Full perimeter gasketing (closed cell Neoprene) between Door frame and lens. • Tamper resistant holt head screws secure lens to housing. A Voltage Ballast Options 120 = 120V See page 4.195 See page 4.195 277 = 277V and page 4.130 UNV= 120-277V • 45° mitered corners (body and Door frame). • Only 5-1/2" deep. • 54.9% efficient (2 lamp T8).1x4 • 55.5% efficient (2U lamp T8). (Elec. T8 Ballast only) • 65.2% efficient (4 lamp T8). • Side mounted ballast for cooler operation. GVB2SFSVL26UUNVHI Candlepower Curve Reference data 5 ½" (140mm) Electronic ballast 450 Ordering information Type Size Flat Steel Door 2' x 2' Example 60˚ Input watts (120V) 60.7W 24" (610mm) • Fully enclosed wiring. • Meets NYC Code requirements. Efficiency 55.5% Spacing ratio 1.3 Options & accessories page 4.130 Ballast: Specify voltage (120, 277 or UNV) and type and add as suffix, e.g. UNVHI 900 Lamp qty–Type 2-6" T8 3-TT5 3-1.6"U T8 GVB2SFSVL26U Guardsman Vandal Resistant UNV Surface box GVB2SFSVL26U GVB2SFSVL3FT GVB2SFSVL32U HI 1350 30˚ A HI*, P2** 1-3 Lamp T8 H3*, P3** 03* 1-4 Lamp T8 H4*, P4** 04* Electronic TT5 40 Watt IB*, PR** SB* S0* I3* X3* ** Program start Lens: For optional 9/64" thick (VK) pattern 12, minimum impact strength 80 foot pounds, substitute VL with VK in catalog no. ie GVB2SFSVK432 Candlepower Curve Reference data Efficiency 54.9% Spacing ratio 1.2 Electronic ballast Electronic T8 * Instant start (Elec. T8 Ballast only) 5 ½" (140mm) <10THD <20THD 1-3 Lamp TT5 40 Watt Voltage Ballast Options 120 = 120V See page 4.195 See page 4.195 277 = 277V and page 4.130 UNV= 120-277V GVB1SFSVL232UNVHI Ballast type Electrical/wiring options: For special wiring, fusing, electronic dimming ballasts, or emergency pack, consult factory. Fusing: Suffix: A (Internal fast-blow fusing). 500 60˚ Suffix: C (Internal slow-blow fusing) Input watts (120V) 55.6W 1000 24" (610mm) Ordering information 1500 Type Size Lamp qty–Type Flat Steel Door 1' x 4' 2-T8 Example GVB1SFSVL232 Guardsman Vandal Resistant UNV Surface box 30˚ GVB1SFSVL232 HI A Voltage Ballast Options 120 = 120V See page 4.195 See page 4.195 277 = 277V and page 4.130 UNV= 120-277V (Elec. T8 Ballast only) Comprehensive lighting catalog 7th Edition 4.195 Linear recessed and surface lighting – Specification Guardsman Vandal Resistant Fluorescent wraparound luminaire GV4WB432UNVH4 12 ¹¹6" (306mm) ⅞"Dia. K.O. 2 ¹³¹6" (71mm) Features • Excellent for locations where vandal resistance 13 ⅞" (325mm) is required. • Prismatic lens is 50% DR (impact resistant), and 50% standard acrylic with a nominal thickness of 1/8", withstands 70 ft. lbs. impact without breaking. • Tamper resistant holt head screws secure lens to housing. • Steel end caps, standard. Type Example • Heavy duty, die formed channel of code gauge steel. Options & accessories page 4.130 Ballast type <10THD <20THD Electronic T8 HI*, P2** S0* 1-3 Lamp T8 H3*, P3** 03* 1-4 Lamp T8 H4*, P4** 04* Catalog no. 2-T8 4-T8 GV4WB232 GV4WB432 UNV H4 Options See page 4.196 and page 4.130 ⅞"Dia. K.O. 2 ¹³¹6" (71mm) 13 ⅞" (325mm) Spanner Head Screw Lens Retainer Bracket Reference data End Plate Lens Input watts (120V) 86W LER FL 75 Efficiency 79.8% Spacing ratio 1.4 Electronic ballast ³¹6" K.O. (2) Ordering information Type Size Surface Wraparound 15 5 ⁄ ¹6" x 48" Suffix: C (Internal slow-blow fusing). Example GV4WB332 Guardsman Vandal Resistant Lamp qty–Type Catalog no. 3-T8 GV4WB332 UNV H3 2 ¹³¹6" (71mm) 8 ⅝" (219mm) A Voltage Ballast 120 = 120V See page 4.196 277 = 277V UNV= 120-277V GV4WA232UNVHI 6 ¹³¹6" (173mm) ⅞"Dia. K.O. Options See page 4.196 and page 4.130 Reference data Spanner Head Screw Lens Retainer Bracket End Plate Lens Efficiency 77.8% Spacing ratio 1.4 Electronic ballast Input watts (120V) 59W LER FL 70 ³¹6" K.O. (2) Ordering information Type Size Lamp qty–Type Catalog no. Surface Wraparound 10 5 ⁄ ¹6" x 48" 10 5 ⁄ ¹6" x 96" 2-T8 2-T8 in Tandem (4 total) GV4WA232 GV8WA232 Example GV4WA232 Guardsman Vandal Resistant 4.196 Philips Lightolier Candela Distribution Angle End 0 5 15 25 35 45 55 65 75 85 95 105 115 125 135 145 155 165 175 3116 3123 3020 2814 2506 2040 1178 632 348 95 0 3 6 10 15 13 13 11 11 45 Cross 3116 3119 3063 2941 2716 2285 1348 695 395 229 156 163 119 87 65 48 31 17 11 3116 3107 3099 3020 2830 2285 1257 862 553 372 306 237 162 117 91 65 46 25 14 (Elec. T8 Ballast only) GV4WB332UNVH3 12 ¹¹6" (306mm) A Voltage Ballast 120 = 120V See page 4.196 277 = 277V UNV= 120-277V ** Program start Fusing: Suffix: A (Internal fast-blow fusing). Input watts (120V) 108W LER FL 76 Electronic ballast Lamp qty–Type 15 5 ⁄ ¹6" x 48" GV4WB432 * Instant start Electrical/wiring options: For special wiring, fusing, electronic dimming ballasts, consult factory. End Plate Lens Efficiency 78.2% Spacing ratio 1.4 ³¹6" K.O. (2) Size Guardsman Vandal Resistant • Self-aligning for continuous row mounting. Ballast: Specify voltage (120, 277 or UNV) and type and add as suffix, e.g. UNVHI Reference data Ordering information Surface Wraparound • UL-Listed for direct mounting on low density ceilings and damp locations. Spanner Head Screw Lens Retainer Bracket UNV HI Voltage Ballast 120 = 120V See page 4.196 277 = 277V UNV= 120-277V A Options See page 4.196 and page 4.130 Candela Distribution Angle End 0 5 15 25 35 45 55 65 75 85 95 105 115 125 135 145 155 165 175 2339 2340 2267 2110 1876 1534 866 474 260 68 0 1 4 8 10 9 9 8 8 45 Cross 2339 2337 2302 2208 2053 1730 1020 540 310 184 134 137 94 60 45 34 22 12 7 2339 2331 2328 2274 2133 1757 973 679 453 322 266 205 129 78 60 47 33 17 9 Candela Distribution Angle End 45 Cross 0 1482 1482 1482 5 1482 1482 1479 15 1432 1463 1483 25 1331 1409 1458 35 1186 1313 1375 45 967 1078 1045 55 541 615 568 65 305 329 388 75 162 208 292 85 45 129 251 95 0 111 261 105 1 147 199 115 3 83 107 125 4 48 62 135 6 44 57 145 7 34 47 155 7 21 32 165 5 9 15 175 5 6 7 For complete specification information visit www.lightolier.com Specification – Linear recessed and surface lighting Guardsman Vandal Resistant GSW series ceiling or wall mounted luminaire GS4V232UNVHI Candlepower Curve Reference data 6" (152mm) Efficiency 73.9% Spacing ratio 1.3 Electronic ballast 3 ⅞" (98mm) 400 Input watts (120V) 59.1W LER 62.9 60˚ Features • Excellent for locations where vandal resistance is required, areas such as hallways, stairwells, locker rooms, parking garages and psychiatric hospitals. 800 • For ceiling or wall mounted applications. 1200 Ordering information Type Lamp Length Lamp qty–type 6" x 23 ¹5⁄¹6" 24" 1-T8 2-T8 GS2V117 GS2V217 6" x 48" 48" 1-T8 2-T8 GS4V132 GS4V132 Size GSW Vandal Resistant Ceiling or Wall • Can be vertically or horizontally mounted on wall. • 20 gauge cold rolled steel, post painted, baked white enamel housing. • 18 gauge cold rolled steel post painted baked white enamel end caps, standard. • Linear prismatic lens 50% DR (impact resistant) and 50% standard acrylic with nominal thickness of 1/8", withstands 70 foot pounds of impact without breaking. GS4V232 UNV Guardsman Vandal Resistant GSW Series Voltage Ballast Options 120 = 120V See page 4.197 See page 4.197 277 = 277V and page 4.130 UNV= 120-277V Example HI Catalog no. 30˚ A (Elec. T8 Ballast only) • Tamper resistant holt head screws secure ends to housing. • Only 3-7/8" deep, meets Americans with Disabilities Act for wall mounted fixtures. • Nominal 2' and 4' lengths. • 73.9% efficient (T8 lamps). Options & accessories page 4.130 Ballast: Specify voltage (120, 277 or UNV) and type and add as suffix, e.g. UNVHI " hole (2) 9 32 " hole (2) ⅞" dia. K.O. (2) ⅞" dia. K.O. (3) 9 32 1 ⅞" dia. K.O. Ballast type Electronic T8 <10THD <20THD HI* S0* * Instant start 4" 6" (152mm) 4" 6" (152mm) 23 1516" (608mm) End Cap Threaded Nipple 24" (610mm) 48" (1219mm) Electrical/wiring options: For special wiring, fusing, electronic dimming ballasts, consult factory. Fusing: Suffix: A (Internal fast-blow fusing). Suffix: C (Internal slow-blow fusing). End Cap Nut Nut Nut Required to space fixtures apart so ends can be removed or installed. For continuous row mounting Comprehensive lighting catalog 7th Edition 4.197 Linear recessed and surface lighting – Specification 5" (127mm) IC Series 2' x 4' & 2' x 2' 24" (610mm) 12 Cells (2-T8 or 4-T8) 3" parabolic recessed suitable for thermal insulation contact 5" (127mm) 24" (610mm) ICS2G12LS232UNVC2 18 Cells 24 Cells (3-T8) 5" (127mm) 5" (127mm) 24" (610mm) Features • UL Listed Type IC Recessed Luminaire (Intended for Thermal Insulated Contact). 24" (610mm) 18 Cells 24 Cells (3-T8 or 4-T8) 12 Cells (2-T8 or 4-T8) • Ideal for fire rated ceilings. • Black exterior for cooler ballast operating temperature. • 5" deep body (2x4, 2x2) • Hemmed over side rails for maximum safety. • Fixture ends turned-in for safe handling. • Built-in earthquake clips. • Pre-anodized aluminum parabolic louver. • 18 gauge steel hinges. 12Cells (3-T8 2-T8 18 Cells 24 or 4-T8)ICS2G12LS232 12 4-T8 ICS2G12LS432 ICS2F12LS232 ICS2F12LS432 ICS2T12LS232 ICS2T12LS432 3-T8 3-T8 5" ICS2G18LP332 (127mm) ICS2G24LP332 ICS2F18LP332 ICS2F24LP332 ICS2T18LP332 ICS2T24LP332 1824" (610mm)3-T8 4-T8 ICS2G18LS332 ICS2G18LS432 ICS2F18LS332 ICS2F18LS432 ICS2T18LS332 ICS2T18LS432 32 ICS2G32LS432 ICS2F32LS432 ICS2T32LS432 Static page 4.130 Example C2* C3* 1-4 Lamp Elect T8 C4* 1-3 Lamp TT5 (40W) NI* Electronic TT5 (40W) NJ* Drywall kit: Catalog no.: FK92X4 for 2'x4' troffer; FK92X2 for 2'x2' troffer Chicago Plenum: For products that meet Chicago Plenum requirements, add Suffix: C. 4-T8 ICS2G12LS232 5" (127mm) 24" (610mm) 9 Cells or 12 Cells (3-T8U1.6) 5" (127mm) 24" (610mm) 16 Cells (2-T8U6) 9 Cells or 12 Cells (3-TT5) Ordering information Lamp Cells qty–type 24" (610mm) 5" (127mm) Exposed T-Grid 2-T8U6 ICS2G9LS26U 9 Cells or 912 Cells (3-T8U1.6) 12 2-T8U6 ICS2G12LS26U 2-T8U6 Flanged for dry wall or plaster Slot-T or Concealed T ICS2F9LS26U ICS2F12LS26U ICS2G9LS26U ICS2T12LS26 5" ICS2G16LS26U (127mm) ICS2F16LS26U ICS2T16LS26U ICS2G9LP32U ICS2G12LP32U ICS2F9LP32U ICS2F12LP32U CS2T9LP32U ICS2T12LP32U ICS2G9LP3FT ICS2G12LP3FT ICS2G12LP3FT ICS2G12LP3FT ICS2T9LP3FT ICS2T12LP3FT 9 3-T8U1.6 24" (610mm)3-T8U1.6 12 9 Cells or 912 Cells (3-TT5) 3-TT5 Example Options See page 4.198 and page 4.130 24" (610mm) 24" (610mm) 12 A 16 Cells (2-T8U6) 5" (127mm) Type 5" (127mm) 5" (127mm) 24" (610mm) 16 3-TT5 ICS2G9LS26U IC Series 3" Parabolic Recessed Suitable for Thermal Insulation Contact Philips Lightolier 24" (610mm) C2 Voltage Ballast 9 Cells or 12 Cells (2-T8U6) UNV= 120-277V See page 4.198 (Elec. T8 Ballast only) 9 Cells or 12 Cells (2-T8U6) Static 4.198 UNV 5" (127mm) Continuous row installation: For F type fixtures, half-width flanges are required between fixtures. Catalog no.: 2FCTrim for each joint. Plaster frame: For F type troffers, order plaster frames separately. Catalog no.: PF24 for 2'x4' troffer; PF22 for 2'x2' troffer. 18 24 ICS2G9LS26UNVC2 * Instant start High Efficiency. Electrical/wiring options: For special wiring, fusing, electronic dimming ballasts, consult factory. Exposed T-Grid IC Series 3" Parabolic Recessed Suitable for Thermal Insulation Contact Ballast type <10THD 1-3 Lamp Elec T8 Lamp qty–type 24" (610mm) Cells 18 32 Cells (4-T8) Louver: Finish Low iridescence semi-specular is standard. Consult factory for other finishes. Ballast: Specify voltage (UNV) and type and add as suffix, e.g. UNVC4. 5" (127mm) Slot-T or Concealed T • Louver has protective film dust guard. Electronic T8 32 Cells (4-T8) Flanged for dry wall or plaster Type • Spring loaded rooster head latches. Options & accessories 24" (610mm) 24" (610mm) 18 Cells 24 Cells (3-T8) Ordering information • 77.7% efficient (3 light 18 cell) 5" (127mm) 5" (127mm) • Construction provides optimum thermal performance. UNV C2 Voltage UNV= 120-277V Ballast See page 4.198 (Elec. T8 or TT5 Ballast only) A Options See page 4.198 and page 4.130 For complete specification information visit www.lightolier.com Specification – Linear recessed and surface lighting IC Series 2' x 4' & 2' x 2' Recessed lensed static suitable for thermal insulation contact ICS2GFSVI432UNVC4 4 Lamp Data 5" (127mm) Reference data Efficiency 81.2% Spacing ratio 1.3 24" (610mm) Features • UL Listed Type IC Recessed Luminaire (Intended for Thermal Insulated Contact). Electronic ballast 5" (127mm) Input watts (120V) 108.7W Ballast factor 73.2 • Construction provides optimum thermal performance. 24" (610mm) • Ideal for fire rated ceilings. • Black exterior for cooler ballast operating temperature. 5" (127mm) • 5" deep body (2x4, 2x2) • 81.2% efficient (4 light) 24" (610mm) • Hemmed over side rails for maximum safety. Ordering information Type Size Static 2' x 4' Example Lamp qty–type 2-T8 3-T8 4-T8 • Fixture ends turned-in for safe handling. Exposed T-Grid Flanged for dry wall or plaster • Built-in earthquake clips. ICS2GFSVI232 ICS2GFSVI332 ICS2GFSVI432 ICS2FFSVI232 ICS2FFSVI332 ICS2FFSVI432 • Spring loaded rooster head latches. ICS2GFSVI432 UNV IC Series Recessed Lensed Static Suitable for Thermal Insulation Contact • True Mitered corner steel lens frame. • 18 gauge steel hinges. • Flat and regressed aluminum doors available. C4 • Construction to meet Chicago Plenum requirements is available. A Voltage Ballast UNV= 120-277V See page 4.199 (Elec. T8 Ballast only) Options See page 4.199 and page 4.130 Options & accessories page 4.130 Special lenses: VI lens is standard virgin acrylic. For other available lenses, see page 4.130. Ballast: Specify voltage (UNV) and type and add as suffix, e.g. UNVC2. Ballast type <10THD ICS2GFSVI26UUNVC2 & ICS2GFSVI32UUNVC3 5" (127mm) 24"(610mm) (610mm) 24" 5" (127mm) 2 Lamp Data 3 Lamp Data Reference data Reference data Efficiency 71.6% Spacing ratio 1.3 Efficiency 67.9% Spacing ratio 1.3 Electronic ballast Electronic ballast Input watts (120V) 56.3W Ballast factor 58.6 Input watts (120V) 76.2W Ballast factor 64.1 24" (610mm) Static Example Size Lamp qty–type Exposed T-Grid Flanged for dry wall or plaster 2' x 2' 2-T8U6 3-TT5 3-T8U1.6 3-T8F17 ICS2GFSVI26U ICS2GFSVI3FT ICS2GFSVI32U ICS2GFSVI317 ICS2FFSVI26U ICS2FFSVI3FT ICS2FFSVI32U ICS2FFSVI317 ICS2GFSVI26U IC Series Recessed Lensed Static Suitable for Thermal Insulation Contact UNV Voltage UNV= 120-277V C2 Ballast See page 4.199 (Elec. T8 or TT5 Ballast only) C2* 1-3 Lamp Elec T8 C3* 1-4 Lamp Elect T8 C4* 1-3 Lamp TT5 40 Watt NI* Electronic TT5 40 Watt NJ* * Instant start High Efficiency. Electrical/wiring options: For special wiring, fusing, electronic dimming ballasts, consult factory. Continuous row installation: For F type fixtures, half-width flanges are required between fixtures. Catalog no.: 2FCTrim (each joint, 2x2, 2x4). Ordering information Type Electronic T8 Plaster frame: For F type troffers, order plaster frames separately. Catalog no.: PF24 for 2'x4' troffer; PF22 for 2'x2' troffer. Door frames Available: ICS2GFS (flatsteel door), ICS2GFA (flat aluminum door) ICS2GRA (regressed aluminum door). A Options See page 4.199 and page 4.130 Chicago Plenum: For products that meet Chicago Plenum requirements, add Suffix: C. Fusing: Suffix: A (Internal fast-blow fusing). Suffix: C ( Internal slow-blow fusing.) Comprehensive lighting catalog 7th Edition 4.199 Linear recessed and surface lighting – Specification TU Turret Industrial Fluorescent premium open industrial luminaire TU4A232UNVHI Features • Rugged telescoping turret lampholders. • Reflector is embossed for rigidity. Candlepower Curve Reference data 4 ⅛" (105 mm) • Optimum 5 3/8" lamp spacing (2 lamp units). Efficiency 91.7% Spacing ratio 1.3 • Reflector sides are turned up for rigidity and safe handling. Electronic ballast 6 ⅛" (156 mm) • 12% aperture reflector, standard. • Solid top reflector, optional. • Reflector secured to housing with easy to use thumb screws. • 4 1/8" wide clevis type housing channel. 11 ¾" (298 mm) • Fully enclosed wiring. Input watts (120V) 61W LER FI 80 5 ⅜" (127 mm) 1450 60˚ 2900 30˚ • Optional porcelain reflectors. • Optional slide grip hangers. Ordering information • Optional heavy duty coupling, wire guards and reflector aligners. Type Fixture length 12% Uplight 49 ½" 49 ½" 99 ⅞" 99 ⅞" 96" 96" 48" 96" 48" 96" 48" 48" 48" 48" 96" 96" 48" 96" 48" 96" 2-T8 3-T8 2-T8 in Tandem (4 total) 3-T8 in Tandem (6 total) 2-T8SL 2-T8HO 2-T12HO 2-T12HO 2-T12VHO 2-T12VHO TU4A232 TU4A332 TU8A232 TU8A332 TU8A259SL TU8A286HO TU4A248HO TU8A296HO TU4A248VO TU8A296VO Solid Top No Uplight 49 ½" 49 ½" 99 ⅞" 99 ⅞" 96" 96" 48" 96" 48" 96" 48" 48" 48" 48" 96" 96" 48" 96" 48" 96" 2-T8 3-T8 2-T8 in Tandem (4 total) 3-T8 in Tandem (6 total) 2-T8SL 2-T8HO 2-T12HO 2-T12HO 2-T12VHO 2-T12VHO TU4S232 TU4S332 TU8S232 TU8S332 TU8S259SL TU8S286HO TU4S248HO TU8S296HO TU4S248VO TU8S296VO page 4.217 Ballast: Specify voltage (120, 277 or UNV) and type and add as suffix, e.g. TU4A232UNVHI Ballast type <10THD <20THD Electronic T12 H0 – SS Std. Mag. HO/VHO – PH Electronic T8 HI*, P2** 1 - 3 Lamp Electronic T8 H3*, P3** 03* 1 - 4 Lamp Electronic T8 H4*, P4** 04* SO* * Instant start ** Program start Cold weather ballasts: T12 HO lamped fixtures are standard with –20°F ballasts. To specify cold weather (0°F) ballasts for RS or T8 fixtures. Suffix: CW. Reflector Row Aligners: For continuous row installations, specify two additional bulk-packed aligners. Order Catalog no. TU - SNA. Example Housing row couplers: For continuous row mounting (stem/chain). One per joint required. Order cat. no. LFL - 3. Side-grip hangers: Accepts 1/2" thread stems or rods. Slides into fixture chassis grooves. Order cat. no. LFL - 111. Chain hanger kit: Order catalog no. LFL - 123. 4' Wire guard: Order catalog no. LFL - 173. 4.200 Philips Lightolier Lamp length TU4A232 Turret Industrial Fluorescent Premium Open Industrial Luminaire Lamp qty/type UNV Catalog no. HI A Voltage Ballast Options 120 = 120V See page 4.200 See page 4.200 277 = 277V and page 4.217 UNV= 120-277V (Elec. T8 32W Ballast only) For complete specification information visit www.lightolier.com Standard – Linear recessed and surface lighting KD/KW Industrial Standard open industrial luminaire KW4S232UNVHI Features Candlepower Curve Reference data 4 ⅝" (117mm) Efficiency 88.4% Spacing ratio 1.5 • Reflector sides are turned up for rigidity and safe handling. • Solid top reflector, standard. Electronic ballast 4 ⅜" (103mm) • Reflector is embossed for rigidity. • 10% aperture reflector, optional. Input watts (120V) 62.0W LER FI 75.3 10 ½" (267mm) 500 60˚ • 4 1/8" wide housing channel. • U.L. Listed snap-on end caps. • Fully enclosed wiring. 1000 • Combination end cap for continuous row mounting. • Optional hangers, wire guards and aligners. 1500 Solid Top No Uplite 10% Uplite Example • Optional heavy duty coupling. • Convenience outlet and switch K.O.’s provided. Ordering information Type 30˚ Fixture length Lamp length 48" 96" 96" 96" 96" 48" 96" 48" 96" 48" 48" 96" 96" 96" 48" 96" 48" 96" 2-T8 2-T8 in Tandem (4 total) 2-T8SL 2-T8HO 2-T12SL 2-T12HO 2-T12HO 2-T12VHO 2-T12VHO KW4S232 KW8S232 KW8S259SL KD8S286HO KW8S296SL KD4S248HO KD8S296HO KD4S248VO KD8S296VO 48" 96" 96" 96" 96" 48" 96" 48" 96" 48" 48" 96" 96" 96" 48" 96" 48" 96" 2-T8 2-T8 in Tandem (4 total) 2-T8SL 2-T8HO 2-T12SL 2-T12HO 2-T12HO 2-T12VHO 2-T12VHO KW4A232 KW8A232 KW8A259SL KD8A286HO KW8A296SL KD4A248HO KD8A296HO KD4A248VO KD8A296VO KW4S232 Turret Industrial Standard Open Industrial Luminaire Lamp qty/type UNV Catalog no. HI A Voltage Ballast Options 120 = 120V See page 4.201 See page 4.201 277 = 277V and page 4.217 UNV= 120-277V (Elec. T8 32W Ballast only) Options & accessories page 4.217 Ballast: Specify voltage (120, 277 or UNV) and type and add as suffix, e.g. KW4S232UNVHI Ballast type <10THD <20THD Electronic T12 (H0 & SL) – SS Std. Mag. HO/VHO – PH Electronic T8 HI*, P2** 1 - 3 Lamp Electronic T8 H3*, P3** 03* 1 - 4 Lamp Electronic T8 H4*, P4** 04* SO* * Instant start ** Program start 4' Wire guard: Order two per 8' fixture. Order catalog no. AWG4W CSP. Reflector row aligner: For continuous row installations. Order catalog no. KND CSP. Side grip hanger: Accepts 1/2" thread stems or rods. Slides into fixture chassis grooves. For KW series order NAHW CSP and for KD series order NAHD CSP. Hard surface mounting or twist tee: For KW series order NAH3 CSP and for KD series order NAH3D CSP. Chain hanger kit: Order catalog no. AH5 CSP. Heavy duty housing coupler: Order catalog no. NHDC-W CSP. Comprehensive lighting catalog 7th Edition 4.201 Linear recessed and surface lighting General utility General utility luminaires are used in a wide variety of applications, ranging from the complex to the simple. This section highlights quality surface mounted strip lighting in all T12, T8 and T5 lamp styles. Our SV5 Louver and Lens Series offers many combinations within our SV T5 channel family. Enabling designers to use channels in both a stylish and practical method. Our standard, narrow, wide, deep and staggered channels meet all the requirements for today's construction needs. You will discover that Philips Lightolier provides many solutions for your general utility lighting needs. 4.202 Philips Lightolier For complete specification information visit www.lightolier.com Linear recessed and surface lighting Contents SV5 > 4.204 Catalog numbering logic > 4.214 T5 Strips > 4.206 Surface/wall options > 4.216 Symmetric & Asymmetric Reflectors > 4.208 Industrial options > 4.217 SD Deep Strip > 4.210 Drywall kit > 4.218 SS Staggered Strip > 4.211 The ULM Module > 4.219 SM Side Mount Strip > 4.211 Ballast code options > 4.220 SN Strip > 4.212 Air handling data > 4.222 SW Strip > 4.213 Comprehensive lighting catalog 7th Edition 4.203 Linear recessed and surface lighting – Specification SV5 louver and lens series For 1 and 2 lamp 46 T5 strip (SV) Stylish, when utilizing either the radial louver or linear ribbed prismatic lens, or practical in instances where no optic is required and shielded light is required. The SV5 Series offers many combinations within its offering that allows combinations of either solid, slotted or peforated reflector designs to be interchanged with different radial louver or lens options. The new reflector design also offers a nice alternative to the standard straight blade reflector when used without the lens/louver option. The SV5 Series is retro-fittable with SV4 Series strip. Features • 90.6 % Efficiency - based on 1-54W SV Strip with perforated reflector and clear linear ribbed lens. • 86.1% Efficiency - Based on 2-28W SV Strip with perforated reflector and perforated radial louver. • Post painted with high efficiency white powdered paint. Complete SV5 Luminaire SV4 Strip SV5 Reflector and shielding options (1 or 2 lamps) Complete SV5 luminaire • Lay-in design optic allows for easy lamp maintenance. • Low profile 3” 11-16 profile when installed. + • Tooled radial louver ensures design consistency in continuous row applications. = • Retro-fittable with CFI Brand SV4 T5 Strip. • Louver - solid or perforated pattern radial blade. • Lens - frosted linear or clear linear Louver options SV5LVW4SPER Two 28W T5 Fluorescent lamps 2" (51mm) 2 916" (42mm) 3 1116" (94mm) 4 " (103mm) 1 16 4 ⅞" (124mm) Options & accessories Stem and canopy sets: Suspend luminaire 12", 18", 24", 36", or 48" from surface. (Two per luminaire is recommended.) Catalog no.: SV5F12 (12"); SV5F18 (18"); SV5F24 (24"); SV5F36 (36"); SV5F48 (48"). Aircraft cable kit: Cat No: SVCC60-UNV (adj. 6"-60") 60" SV5 Power Feed, Cable and Canopy Kit Cable and canopy kit: Cat No: SVC60 (adj. 6"-60") Chain hanging kit: Cat No: EE9HC Includes two 5' heavy duty link chains with sturdy “V” hook for fixture suspension. Rocker switches and convenience outlets: Certain combinations of the SV Series strip with the new SV5 Reflector assembly will not accommodate these options. Please consult the specification sheets or your Philips Lightolier representative to validate the request. 4.204 Philips Lightolier Dimensions are the same for 1 or 2-lamp luminaire. RCR C.U. 1 2 3 4 5 6 7 8 9 10 91 83 76 70 64 59 54 50 46 43 Ordering information White Perforated Reflector with White Perforated Radial Blade White Solid Reflector with Grey Solid Radial Blade Efficiency 86.1% Spacing ratio 1.5 Electronic ballast 60˚ 0 Input watts (120V) 64.0W Luminaire Eff (LER) 1.0 0 0 30˚ Application data* Length SV5 Reflector (nom) and louver* Type Candlepower Curve Reference data 46" 46" SV5LVW4SPER** SV5LGW4SSLD** Luminaire spacing FC W/Sq Ft 50' x 70' x 8.5' Space 8' on center 51 30' x 30' x 8.5' Space 10' on center 53 1.14 10' x 8' x 8' Space 6' on center 43 1.28 6' x 8' x 8' Space Work Cell 36 1.33 1.02 * Average foot candles maintained. Total Light Loss Factor LLF=.90 Reflectances: 80% Ceiling, 50% Wall, 20% Floor RE835 T5/T5HO lamp lumens at 4400 rated at 25C. * Only for use with 1 or 2-lamp T5 Strip (SV) ** For Slotted White Reflector, replace Solid White SLD by SLT. For Perforated White Reflector, replace Solid White SLD by PER. For White Perforated Radial Blade Louver, replace LW with LV. For Grey Perforated Radial Blade Louver, replace LG with LH Example SV5 SV5 Reflector Accessory LV W4 Louver design LV = White / Perforated Blade LW= White / Solid Blade LG = Grey / Solid Blade LH = Grey / Perforated Blade S Reflector Light dist. W4 = Nominal S = Symmetric 46” White (Std) PER Reflector style SLD = Solid SLT = Slotted PER = Perforated For complete specification information visit www.lightolier.com Specification – Linear recessed and surface lighting SV5 louver and lens series For 1 and 2 lamp 46 T5 strip (SV) SV5CLW4SPER One 54W T5 HO Fluorescent lamp 2" (51mm) 2 916" (42mm) 3 1116" (94mm) 4 116" (103mm) 4 ⅞" (124mm) Dimensions are the same for 1 or 2-lamp luminaire. RCR C.U. 1 2 3 4 5 6 7 8 9 10 95 86 79 72 66 61 56 51 47 44 Efficiency 90.6% Spacing ratio 1.3 Electronic ballast 60˚ 0 Input watts (120V) 64.0W Luminaire Eff (LER) 1.1 • 86.1% Efficiency - Based on 2-28W SV Strip with perforated reflector and perforated radial louver. 0 30˚ Application data* Length SV5 Reflector (nom) and louver* White Perforated Reflector with Clear Linear Lens 46" White Solid Reflector with Frosted Linear Lens 46" SV5CLW4SPER** Luminaire spacing FC W/Sq Ft 50' x 70' x 12' Space 8' on center 45 0.92 30' x 30' x 8.5' Space 10' on center 46 1.06 10' x 8' x 8' Space 8' on center 37 1.19 6' x 8' x 8' Space Work Cell 36 1.25 • Low profile 3” 11-16 profile when installed. • Tooled radial louver ensures design consistency in continuous row applications. • Retro-fittable with CFI Brand SV4 T5 Strip. * Only for use with 1 or 2-lamp T5 Strip (SV) ** For Perforated White Reflector, replace Solid White SLT by PER SV5 Example CL SV5 Reflector Accessory Reflector W4 = Nominal 46” White (Std) S Options & accessories 2 916" (42mm) 3 1116" (94mm) Dimensions are the same for 1 or 2-lamp luminaire. RCR C.U. 1 2 3 4 5 6 7 8 9 10 96 88 80 74 67 62 57 52 48 44 Ordering information White Solid Reflector Candlepower Curve Reference data Efficiency 87.8% Spacing ratio 1.5 Electronic ballast 60˚ 0 Input watts (120V) 64.0W Luminaire Eff (LER) 1.0 46" SV5XXW4SSLD** SV5XXW4SSLD** SV5XXW4SSLD** Stem and canopy sets: Suspend luminaire 12", 18", 24", 36", or 48" from surface. (Two per luminaire is recommended.) Catalog no.: SV5F12 (12"); SV5F18 (18"); SV5F24 (24"); SV5F36 (36"); SV5F48 (48"). Aircraft cable kit: Cat No: SVCC60-UNV (adj. 6"-60") 60" SV5 power feed, cable and canopy kit Cable and canopy kit: Cat No: SVC60 (adj. 6"-60") 0 Chain hanging kit: Cat No: EE9HC Includes two 5' heavy duty link chains with sturdy “V” hook for fixture suspension. 0 0 30˚ Application data* Length SV5 Reflector (nom) and louver* Type Reflector style SLT = Slotted PER = Perforated Two 28W T5 Fluorescent lamps 2" (51mm) 4 ⅞" (124mm) • Lens - frosted linear or clear linear PER Light dist. S = Symmetric SV5XXW4SSLD 4 116" (103mm) • Louver - solid or perforated pattern radial blade. Lens options W4 Louver design CL = Clear Linear Lens FL= Frosted Linear Lens • Post painted with high efficiency white powdered paint. • Lay-in design optic allows for easy lamp maintenance. * Average foot candles maintained. Total Light Loss Factor LLF=.90 Reflectances: 80% Ceiling, 50% Wall, 20% Floor RE835 T5/T5HO lamp lumens at 4400 rated at 25C. SV5FLW4SSLT** Features • 90.6 % Efficiency - Based on 1-54W SV Strip with perforated reflector and clear linear ribbed lens. 0 Ordering information Type Candlepower Curve Reference data Luminaire spacing FC W/Sq Ft 50' x 70' x 12' Space 8' on center 45 0.88 30' x 30' x 8.5' Space 10' on center 34 0.64 10' x 8' x 8' Space 8' on center 22 0.64 6' x 8' x 8' Space Work Cell 28 1.33 Rocker switches and convenience outlets: Certain combinations of the SV Series strip with the new SV5 Reflector assembly will not accommodate these options. Please consult the specification sheets or your Philips Lightolier representative to validate the request. * Average foot candles maintained. Total Light Loss Factor Lens option not available with a solid reflector LLF=.90 Reflectances: 80% Ceiling, 50% Wall, 20% Floor RE835 * Only for use with 1 or 2-lamp T5 Strip (SV) T5/T5HO lamp lumens at 4400 rated at 25C. ** For Slotted White Reflector, replace Solid White SLD by SLT. For Perforated White Reflector, replace Solid White SLD by PER. Example SV5 XX W4 S SV5 Louver design Reflector Light dist. Reflector XX = No Lens / Louver W4 = Nominal S = Symmetric Accessory 46” White (Std) SLD Reflector style SLD = Solid (N/A with Lens option) SLT = Slotted PER = Perforated Comprehensive lighting catalog 7th Edition 4.205 Linear recessed and surface lighting – Specification T5 strip series 22", 34", 46", 92" Surface strips (SV) SV4S228UNVPG 2 T5 Strip 1⅜" (35mm) 2⅜" (60mm) 2" (51mm) 1⅜" (35mm) RCR C.U. 1 2 3 4 5 6 7 8 9 10 90 77 67 59 52 46 41 37 33 30 Candlepower Curve Reference data Efficiency 93,3% Spacing ratio 1.5 Electronic ballast Input watts (120V) 66.0W Ballast factor 1.0 • Only 2" Wide. • Utilizes compact, high efficiency, T5 or T5HO lamps. • Fully enclosed wiring. • Optional white or specular, symmetric and assymetric reflector. • Optional hangers and guards. 1050 30˚ 2" (51mm) Ordering information Example Length Number Type (nominal) of lamps • Convenience outlet and switch K.O.s provided. • Push through lamp holders with rotor for secure lamp retention. 60˚ 700 2⅜" (60mm) Features 350 Strip T5 22" 22" 34" 34" 46" 46" 92" 92" 1 2 1 2 1 2 2 (tandem) 4 (tandem) T5 SV2S114 SV2S214 SV3S121 SV3S221 SV4S128 SV4S228 SV8S128 SV8S228 SV4S228 T5HO Strip T5 Surface Strips SV2S124 SV2S224 SV3S139 SV3S239 SV4S154 SV4S254 SV8S154 SV8S254 UNV PG Voltage Ballast Options 120 = 120V See next page See next page 277 = 277V UNV= 120-277V T5 side-mount strip series 26", 38", 50" Surface side-mount strips (SM) SM4S228UNVPG 2 T5 Sidemount Strip 1 ⅜" (35mm) 2" (51mm) 3" (76mm) 1 ⅜" (35mm) RCR C.U. 1 2 3 4 5 6 7 8 9 10 86 74 65 57 50 45 40 36 33 30 Candlepower Curve Reference data Efficiency 94,5% Spacing ratio 1.4 Electronic ballast Input watts (120V) 66.0W Ballast factor 1.0 60˚ 350 2" (51mm) 4" (102mm) Features • Only 1 3/8" deep. • Utilizes compact, high efficiency, T5 or T5HO lamps. • Fully enclosed wiring. • Convenience outlet and switch K.O.s provided (1 lamp only). • Push through lamp holders with rotor for secure lamp retention. 4.206 Philips Lightolier Ordering information Type Sidemount Strip T5 Length Number (nominal) of lamps 22" 22" 34" 34" 46" 46" 700 Example 1 2 1 2 1 2 SM4S228 T5 T5HO SM2S114 SM2S214 SM3S121 SM3S221 SM4S128 SM4S228 Strip T5 SM2S124 Surface Strips SM2S224 SM3S139 SM3S239 SM4S154 SM4S254 UNV 30˚ PG Voltage Ballast Options 120 = 120V See next page See next page 277 = 277V UNV= 120-277V For complete specification information visit www.lightolier.com Specification – Linear recessed and surface lighting T5 staggered strip series 26", 38", 50" Surface staggered strips SS4S228UNVPG 2 T5 Staggered Strip 1 716" (37mm) 2 ⅜" (60mm) 3 ⅛" (79mm) 4" (102mm) RCR C.U. 1 2 3 4 5 6 7 8 9 10 88 76 66 58 50 45 40 36 32 29 Candlepower Curve Reference data Efficiency 90,4% Spacing ratio 1.5 Features Electronic ballast Input watts (120V) 66.0W Ballast factor 1.0 • Only 2" Wide. 0 • Utilizes compact, high efficiency, T5 or T5HO lamps. 60˚ 0 0 30˚ 4" (102mm) 50" (1270mm) Options & accessories 26 ½" (673mm) T5 T5HO 26 ½" 26 ½" Staggered 38 ¼" Strip T5 38 ¼" 50" 50" SS2S114 SS2S214 SS3S121 SS3S221 SS4S128 SS4S228 SS2S124 SS2S224 SS3S139 SS3S239 SS4S154 SS4S254 SS4S228 UNV page 4.216 Ballast: Specify voltage (120, 277 or UNV) and type and add as suffix, e.g. UNVPG. Length Number Type (nominal) of lamps Staggered Strip T5 Surface Strips • Convenience outlet and switch K.O.s provided. • Optional hangers and guards. 38 ¼" (972mm) Ordering information Example • Optional white or specular, symmetric and assymetric reflector. • Push through lamp holders with rotor for secure lamp retention. 4" (102mm) 1 2 1 2 1 2 • Fully enclosed wiring. Ballast type Application data* Luminaire spacing FC W/Sq Ft 50' x 70' x 8.5' Space 12' on center 29 .45 30' x 30' x 8.5' Space 10' on center 36 .66 12' x 16' x 8.5' Space 8' on center 1.4 54 * Average footcandles mounted total LLF Reflectance 60% ceiling, 50% wall, 20%. Floor T5 rated at 2610 lumens (25°C). PG Voltage Ballast Options 120 = 120V See page 4.207 See page 4.207 277 = 277V and page 4.216 UNV= 120-277V Electronic T5 (1 or 2 LPB) Program start PG Electronic T5 (1 or 2 LPB) Power Spec Dimming PF (120/277V only) LPB = Number of lamps per ballast. Radio interference filter: Suffix: R. 120 or 277 volt at 50 or 60Hz. Stem and canopy sets: Suspend luminaire 12", 18", 24", 36", or 48" from surface. (Two per luminaire is recommended. For 34" and 46" SV Strip only.) Catalog no.: SV5F12 (12"); SV5F18 (18"); SV5F24 (24"); SV5F36 (36"); SV5F48 (48") Chain hanging kit: Includes two 5' heavy duty link chains with sturdy “V” hook for fixture suspension. (34" and 46" SV Strip only.) Catalog no.: AH5 CSP Wire guard: white wire guard. Catalog no.: For SV Strip T5 34": SV5GXW3 For SV Strip T5 46": SV5GXW4 Reflectors: See Page page 4.208 + 4.209 Comprehensive lighting catalog 7th Edition 4.207 Linear recessed and surface lighting – Specification Symmetric reflector 2', 3', 4' For 1 or 2 lamps T5 strip (SV) SV5R1S4SSLD / SV4S154UNVPG 2" (51mm) 1 ⅜" (35mm) 2 ½" (64mm) 4 ⅛" (105mm) 1 T5 Symmetric Silver RCR C.U. 1 2 3 4 5 6 7 8 9 10 90 77 67 59 52 46 41 37 33 30 Ordering information • Only 1 ⅜" deep. • Installation on regular SV T5 strip, 1 or 2 lamps. • Available in white or high reflectivity specular finish. • Optional micro-perforated or slotted white reflector. Efficiency 87,5% Spacing ratio 1.9 Electronic ballast 60˚ 300 Input watts (120V) 64.0W Ballast factor 1.0 600 900 30˚ Application data* Reflector for T5 Strip* Luminaire spacing 50' x 70' x 8.5' Space 12' on center 25 .44 Symetric Reflector White 22" 34" 46" 92" 2X SV5R1W2SSLD** SV5R1W3SSLD** SV5R1W4SSLD** SV5R1W4SSLD** 30' x 30' x 8.5' Space 10' on center 31 .64 12' x 16' x 8.5' Space 8' on center 1.3 Symetric Reflector Silver 22" 34" 46" 92" 2X SV5R1S2SSLD SV5R1S3SSLD SV5R1S4SSLD SV5R1S4SSLD Type Features Length (nominal) Candlepower Curve Reference data FC W/Sq Ft 47 * Average footcandles mounted total LLF =.90 Reflectance 80% ceiling, 50% wall, 20% Floor T5 rated at (25°C). Lamp rated at 2610 lumens * Use with 1 or 2 T5 Strip (SV) ** For Slotted White Reflector, replace Solid White SLD by SLT For Microperforated White Reflector, replace Solid White SLD by PER SV5R1W4SSLD / SV4S254UNVPG 2" (51mm) 1 ⅜" (35mm) 2 ½" (64mm) 4 ⅛" (105mm) RCR C.U. 1 2 3 4 5 6 7 8 9 10 86 74 65 57 50 45 40 36 33 30 Ordering information Length (nominal) 2 T5 Symmetric White Candlepower Curve Reference data Efficiency 78.7% Spacing ratio 1.4 Electronic ballast 60˚ 300 Input watts (120V) 121.0W Ballast factor 1.0 600 900 30˚ Application data* Reflector for T5 Strip* Luminaire spacing Symetric Reflector White 22" 34" 46" 92" SV5R1W2SSLD** SV5R1W3SSLD** SV5R1W4SSLD** 2X SV5R1W4SSLD** 30' x 30' x 8.5' Space 10' on center 51 1.2 12' x 16' x 8.5' Space 8' on center 2.5 Symetric Reflector Silver 22" 34" 46" 92" SV5R1S2SSLD SV5R1S3SSLD SV5R1S4SSLD 2X SV5R1S4SSLD Type FC W/Sq Ft 50' x 70' x 8.5' Space 12' on center 50 84 .83 * Average footcandles mounted total LLF =.90 Reflectance 80% ceiling, 50% wall, 20% Floor T5 rated at (25°C). Lamp rated at 4400 lumens * Use with 1 or 2 T5 Strip (SV) ** For Slotted White Reflector, replace Solid White SLD by SLT For Microperforated White Reflector, replace Solid White SLD by PER 4.208 Philips Lightolier For complete specification information visit www.lightolier.com Specification – Linear recessed and surface lighting Asymmetric reflector 2', 3', 4' For 1 or 2 lamps T5 strip (SV) SV5R1W4ASLD / SV4S154UNVPG 2" (51mm) 1 ⅜" (35mm) 2 ½" (64mm) 3 ⅛" (79mm) RCR C.U. 1 2 3 4 5 6 7 8 9 10 88 76 66 58 50 45 40 36 32 29 1 T5 Asymmetric White Candlepower Curve Reference data Efficiency 91.8% Spacing ratio Electronic ballast 300 Input watts (120V) 64.0W Ballast factor 1.1 60˚ 600 30˚ Ordering information Type Length (nominal) Reflector for T5 Strip* Symetric Reflector White 22" 34" 46" 92" SV5R1W2ASLD** SV5R1W3ASLD** SV5R1W4ASLD** 2X SV5R1W4ASLD** Symetric Reflector Silver 22" 34" 46" 92" SV5R1S2ASLD SV5R1S3ASLD SV5R1S4ASLD 2X SV5R1S4ASLD Features • Only 1 ⅜" deep. • Installation on regular SV T5 strip, 1 or 2 lamps. • Available in white or high reflectivity specular finish. * Use with 1 or 2 T5 Strip (SV) ** For Slotted White Reflector, replace Solid White SLD by SLT For Microperforated White Reflector, replace Solid White SLD by PER SV5R1W4ASLD / SV4S254UNVPG 2" (51mm) 1 ⅜" (35mm) 2 ½" (64mm) 3 ⅛" (79mm) RCR C.U. 1 2 3 4 5 6 7 8 9 10 86 75 65 57 50 45 40 36 32 29 2 T5 Asymmetric White Candlepower Curve Reference data Efficiency 85.8% Spacing ratio Electronic ballast 300 Input watts (120V) 121.0W Ballast factor 1.0 60˚ 600 30˚ Ordering information Type Length (nominal) Reflector for T5 Strip* Symetric Reflector White 22" 34" 46" 92" SV5R1W2ASLD** SV5R1W3ASLD** SV5R1W4ASLD** 2X SV5R1W4ASLD** Symetric Reflector Silver 22" 34" 46" 92" SV5R1S2ASLD SV5R1S3ASLD SV5R1S4ASLD 2X SV5R1S4ASLD * Use with 1 or 2 T5 Strip (SV) ** For Slotted White Reflector, replace Solid White SLD by SLT For Microperforated White Reflector, replace Solid White SLD by PER Comprehensive lighting catalog 7th Edition 4.209 Linear recessed and surface lighting – Specification SD Deep Strip High output/very high output SD8S296HO120SS 5 ⅞" (149mm) 5 1 ⁄16" (T12) (129mm) 2 ¾" (70mm) 4 13 ⁄16" (T8) (122mm) Features ⅞" Dia. K.O. (4) • Fixtures suitable for individual, row, surface, or suspension mounting. • Efficiency 92.3% (T12). 5 ⅞" (149mm) 48" (1220mm) 4" (102mm) 1 Lamp • Quarter turn latch secures channel cover for easy wireway access. 5 1 ⁄16" (T12) (129mm) • Heavy duty channel of code gauge die formed steel. • Fully enclosed wiring. 6 ⅜" (162mm) 2" Dia. K.O. • Green grounding screw installed in channel. 2 Lamp • Lampholders may be individually replaced or rewired. 72" (1829mm) or 96" (2438mm) 24" (610mm) 6" (152mm) 4 ⅝" (117mm) 4 ⅛" (105mm) page 4.216 6 ⅜" (162mm) 2" Dia. K.O. Ballast: Specify voltage (120, 277 or UNV) and type and add as suffix, e.g. 120SO. S Hook K.O. (8) ⅞" Dia. K.O. (4) 6' & 8' Channel Ballast type <10THD <20THD Electronic T8 HI* SO* Electronic P.S. T8 P2 – Electro-Magnetic – PH Elcetronic T12 Standard – SS Candlepower Curve Ordering information Nominal lamp length Lamps qty - type Electrical/wiring options: For special wiring, fusing, electronic dimming ballasts, consult factory. Optional hangers, wire guards & aligners, see page 4.216. 48" 96" 96" 192" 96" 192" 48" 48" 96" 96" 96" 96 1-T12HO 1-T12VHO 1-T12HO 1-T12HO in Tandem (2 Total) 1-T12VHO 1-T12HO in Tandem (2 Total) SD4S148HO SD4S148VO SD8S196HO SD8T196HO SD8S196VO SD8T196VO Fusing: Suffix: A (Internal fast-blow fusing). Suffix: C (Internal slow-blow fusing). 48" 48" 2-T8HO 2-T12HO 2-T12VHO SD4S244HO SD4S248HO SD4S248VO 96" 96" 2-T12HO 2-T12VHO SD8S296HO SD8S296VO 96" 1-T8HO 1-T8 in Tandem (2 Total) 2-T8HO SD8S186HO SD8T186HO SD8S286HO * Instant start. Fixture length 96" 192" 96" Reflectors Catalog no. SD 1 or 2 lamps wide 1400 60˚ 2800 30˚ Reference data Efficiency 92,3% Spacing ratio 1.59 Electronic ballast Input watts (120V) 232W LER = FS 67.3 Accessories Type Size Catalog no. Symmetrical 48" NSYMF48S CSP Asymmetrical 48" NASYF48S CSP Example SD8S296HO SD Strip High Output Very High Output Philips Lightolier S Hook K.O. (8) ⅞" Dia. K.O. (4) 4" (102mm) 3 116" (78mm) • T8 (380mA) and T12 (800mA) standard fixtures include ballasts rated for –20°F starting temperature. 4.210 4 ⅝" (117mm) 4' Channel • Combination end cap for continuous row mounting. Options & accessories 6" (152mm) 1 ⅛" (29mm) 4 ⅛" (105mm) 4 13 ⁄16" (T8) (122mm) • U.L. Listed snap-on end caps. ½" Dia. K.O. (2) Side View AC1 CSP = spacer each. NAH3D CSP = twis tee each. NAHD CSP = slide grip each. AWG3W CSP = wire guard each 4ft. All symmetric and asymmetric reflectors are shipped separately from the fixture . 120 Voltage 120 = 120V 277 = 277V SS Ballast See page 4.210 A Options See page 4.210 and page 4.216 For complete specification information visit www.lightolier.com Specification – Linear recessed and surface lighting SS Staggered Strip Surface strip SS4S132HPFUNVHI SS4S232HPFUNVHI 4 ¼" (110mm) 4 ¼" (110mm) 1 ⅝" (141mm) 3 ¾" (T12) (95mm) 1 Lamp Reference data 3 ½" (T8) (89mm) 1 ⅝" (141mm) 3 ¾" (T12) (95mm) Efficiency 89,5% Spacing ratio 1.6 Ordering information Features 2 Lamp Reference data 3 ½" (T8) (89mm) Efficiency 89,5% Spacing ratio 1.6 Nominal lamp length Lamps qty - type 23 15 ⁄16" 23 15 ⁄16" 35 15 ⁄16" 35 15 ⁄16" 47 15 ⁄16" 68 15 ⁄16" 68 15 ⁄16" 92 15 ⁄16" 24" 24" 36" 36" 48" 36" 36" 48" 1-T8 1-T12 1-T8 1-T12 1-T8 2-T8 2-T12 2-T8 • Fully enclosed wireway. 1 Lamp Catalog no. Fixture length Nominal lamp length Lamps qty - type SS2S117HPF SS2S120HPF SS3S125HPF SS3S130HPF SS4S132HPF SS6T125HPF SS6T130HPF SS8T132HPF 26 15 ⁄16" 26 15 ⁄16" 38 15 ⁄16" 38 15 ⁄16" 50 15 ⁄16" 74 15 ⁄16" 74 15 ⁄16" 98 15 ⁄16" 24" 24" 36" 36" 48" 36" 36" 48" 2-T8 2-T12 2-T8 2-T12 2-T8 4-T8 4-T12 4-T8 2 lamp Reflectors (T8 only) Type Size Catalog no. Type Size Catalog no. Asymmetrical 24" 36" 48" Asymmetrical 24" 36" 48" SS4S132HPF Example UNV SS Strip Narrow Width Channel HI 2 Lamp Catalog no. SS2S217HPF SS2S220HPF SS3S225HPF SS3S230HPF SS4S232HPF SS6T225HPF SS6T230HPF SS8T232HPF 1 lamp T8 Reflectors (T8 only) ASYC20STG ASYC30STG ASYC40STG ASYF24STG ASYF36STG ASYF48STG • Excellent for perimeter cove lighting or other applications where continuous even illumination is required. Options & accessories page 4.216 Ballast: Specify voltage (120, 277 or UNV) and type and add as suffix, e.g. UNVHI. Ballast type <10THD <20THD Electronic T8 HI* SO* 1-4 Lamp Electronic T8 H4* O4* LOL T8 Dimming – PS Magnetic T12 HPF Models LPF Models – – PH PL * Instant start. A Voltage Ballast 120 = 120V See page 4.211 277 = 277V UNV= 120-277V (Elect T8 only) • Housing is only 1 5/8" deep. • Safe-handling metal edges. Ordering information Fixture length • Full 3" overlap eliminates shadows caused by lampholders or lamp ends. Electrical/wiring options: For special wiring, fusing, electronic dimming ballasts, consult factory. Optional hangers, wire guards & aligners, see page 4.216. Options See page 4.211 and page 4.216 Fusing: Suffix: A (Internal fast-blow fusing). Suffix: C (Internal slow-blow fusing). SM Side Mount Strip Surface strip SM132HPFUNVHI 4 ⅛" 4 ⅛" (105mm) (105mm) TOPTOP VIEW VIEW 2"(51mm) 2"(51mm) 1 1316" 1 1316" 2 ½" 2 ½" (66mm) (46mm) (46mm) (66mm) ⅞" K.O. ⅞"(3) K.O. (3) 1 Lamp 1 1316" 1 1316" (46mm) (46mm) 2 Lamp 1¹3¹6" (46mm) 2½" ⅞" K.O. ⅞"(4) K.O. (4) (66mm) 2" (51mm) • Only 1 13/16" deep. • Efficiency 95.8%. TOP VIEW 1 116" (27mm) 1 116" (27mm) SIDESIDE VIEW VIEW 1 116" (27mm) 1 116" (27mm) ⅞" K.O. (3) 5¹¹¹6" (145mm) Features ½" K.O. ½"(2) K.O. (2) Ordering information 1¹ " ½" K.O. (2) 1 ¼" 1 ¼" (32mm) (32mm) 3 ¾" 3 ¾" (95mm) (95mm) Dimensions Channel length Inches 2' Channel 3' Channel 4' Channel 24" 36" 48" (mm) (610 mm) (914 mm) (1219 mm) 1 Lamp 1 Lamp SIDE VIEW 1¹¹6" (27mm) Catalog no. Catalog no. 24" 24" 36" 36" 36" 48" 48" SM117HPF SM120LPF SM125HPF SM130LPF SM130HPF SM134LPF SM132HPF T8 T12 T8 T12 T12 T12 T8 • May be surface mounted or suspended. • Code gauge, heavy duty, die formed steel channel. Nominal Fixture Lamps ⅞" K.O. (4)lamp 1¹¹qty 6" (27mm) length - type length 24" 24" 36" 36" 36" 48" 48" • Fully enclosed wiring. • May be continuous row mounted. 3 ¹6 (46mm) • Ballast cover secured by quarter-turn latches. 3¾" (95mm) SM217HPF SM220LPF SM225HPF – SM230HPF – SM232HPF 1¼" (32mm) • Multiple knockouts for convenient installation. • Lampholders may be individually replaced or rewired. • High reflectance baked white enamel finish. • U.L. Listed for damp locations. Comprehensive lighting catalog 7th Edition 4.211 Linear recessed and surface lighting – Standard SN Strip Narrow width channel SN4S132HPFUNVHI 2 ½" (66mm) 2" (51mm) TOP VIEW 2 ½" (66mm) Features • Fixtures suitable for individual, row, surface, or suspension mounting. ⅞" K.O. (3) 3 1316" (94mm) SIDE VIEW ½" K.O. (2) 1 " (46mm) 13 16 • Efficiency 94% (T8). • Quarter turn latch secures channel cover for easy wireway access. ⅞" K.O. (4) 1 116" (27mm) 1 ¼" (32mm) 1 116" (27mm) 3 ¾" (95mm) • Heavy duty channel of code gauge die formed steel. • Only 2 1/2" wide. Dimensions Reference data • U.L. Listed snap-on end caps. Channel length • Combination end cap for continuous row mounting. 18" Channel 2' Channel 3' Channel 4' Channel 6' Channel 8' Channel Efficiency 94,0% Spacing ratio 1.6 • Fully enclosed wiring. • Green grounding screw installed in channel. • U.L. listed for direct mounting on low density ceilings and damp location. Options & accessories page 4.216 Inches 18" 24" 36" 48" 72" 96" Ballast: Specify voltage (120, 277 or UNV) and type and add as suffix, e.g. UNVHI. Ordering information Ballast type <10THD <20THD Fixture length Electronic T8 HI* SO* LOL T8 Dimming – PS Magnetic T12 Standard Electro-Magnetic LPF Models PL – SS – Electronic T12 HPF Models 18", 24", 36" only * Instant start. Electrical/wiring options: For special wiring, fusing, electronic dimming ballasts, consult factory. Optional hangers, wire guards & aligners, see page 4.216. (mm) (457 (610 (914 (1219 (1829 (2438 mm) mm) mm) mm) mm) mm) Electronic ballast Input watts (120V) 36.0W LER = FS 66.7 30˚ Lamps qty - type 24" 36" 48" 96" 24" 36" 48" 48" 1-T8 1-T8 1-T8 1-T8 in Tandem (2 Total) SN2S117HPF SN3S125HPF SN4S132HPF SN8T132HPF 18" 18" 24" 24" 36" 36" 48" 18" 18" 24" 24" 36" 36" 48" 1-T12 1-T12 1-T12 1-T12 1-T12 1-T12 1-T12 SN1S115HPF SN1S115LPF SN2S120HPF SN2S120LPF SN3S130HPF SN3S130LPF SN4S134LPF Example 60˚ 200 400 Lamp length Fusing: Suffix: A (Internal fast-blow fusing). Suffix: C (Internal slow-blow fusing). Candlepower Curve SN4S132HPF SN Strip Narrow Width Channel Reflectors UNV Catalog no. HI A Voltage Ballast 120 = 120V See page 4.212 277 = 277V UNV= 120-277V (Elect T8 only) Symmetrical Type Size Catalog no. Symmetrical 24" 36" 48" NSYMC20 CSP NSYMC30 CSP NSYMC40 CSP Asymmetrical 24" 36" 48" NASYC20 CSP NASYC30 CSP NASYC40 CSP Options See page 4.212 and page 4.216 Accessories 5 ⅛" (130mm) 6" (152mm) AC1 CSP = spacer each. AWG1W CSP = wire guard each. All symmetric and asymmetric reflectors are shipped separately from the fixture . Asymmetrical 5 ⅛" (130mm) 5 7 ⁄16" (138mm) 4.212 Philips Lightolier For complete specification information visit www.lightolier.com Standard – Linear recessed and surface lighting SW Strip Standard strip wide SW4S232HPFUNVHI Candlepower Curve Reference data Efficiency 97,3% Spacing ratio 1.58 3 ¾" (T12) (95mm) Electronic ballast 3 ½" (T8) (89mm) Input watts (120V) 60.3W LEF = FS 80.5 Features 400 60˚ 1 Lamp • Efficiency 97.3% (T8). 800 3 ¾" (T12) (95mm) 30˚ • Fully enclosed wiring. • U.L. Listed snap-on end caps. 2 Lamp • Combination end cap for continuous row mounting. • Green grounding screw installed in channel. Ordering information • Lampholders may be individually replaced or rewired. Lamp length 1 Lamp -type 24" 36" 48" 96" 96" 24" 36" 48" 48" 96" 1-T8 1-T8 1-T8 1-T8 in Tandem (2 Total) 1-T8 SL SW2S117HPF SW3S125HPF SW4S132HPF SW8T132HPF SW8S159SL 24" 24" 36" 36" 48" 48" 72" 96" 192" 24" 24" 36" 36" 48" 48" 72" 96" 96" 1-T12 1-T12 1-T12 1-T12 1-T12 1-T12SL 1-T12SL 1-T12SL 1-T12 in Tandem (2 Total) SW2S120HPF SW2S120LPF SW3S130HPF SW3S130LPF SW4S134LPF SW4S148SL SW6S172SL SW8S196SL SW8T196SL Example • Quarter turn latch secures channel cover for easy wireway access. • Heavy duty channel of code gauge die formed steel. 3 ½" (T8) (89mm) Fixture length • Fixtures suitable for individual, row, surface, or suspension mounting. SW4S232HPF SW Strip Standard Strip Wide 2 Lamp Catalog no. • U.L. listed for direct mounting on low density ceilings and damp locations. 2-T8 2-T8 2-T8 2-T8 (in Tandem -2 Total) 2-T8 SL SW2S217HPF SW3S225HPF SW4S232HPF SW8T232HPF SW8S259SL Ballast: Specify voltage (120, 277 or UNV) and type and add as suffix, e.g. UNVHI. 2-T12 2-T12 2-T12 2-T12 2-T12 2-T12SL 2-T12SL 2-T12SL – SW2S220HPF SW2S220LPF SW3S230HPF SW3S230LPF SW4S234LPF SW4S248SL SW6S272SL SW8S296SL – 1 Lamp Catalog no. UNV 2 Lamp -type HI Voltage Ballast 120 = 120V See page 4.213 277 = 277V UNV= 120-277V (Elect T8 only) A Options See page 4.213 and page 4.216 Options & accessories page 4.216 Ballast type <10THD <20THD Electronic T8 HI* SO* 1-4 Lamp Electronic T8 H4* O4* LOL T8 Dimming – PS Magnetic T12 Standard Electro-Magnetic LPF Models – PL Electronic T12 Standard Electro-Magnetic – HPF and SL Models SS * Instant start. Electrical/wiring options: For special wiring, fusing, electronic dimming ballasts, consult factory. Optional hangers, wire guards & aligners, see page 4.216. Fusing: Suffix: A (Internal fast-blow fusing). Suffix: C (Internal slow-blow fusing). Reflectors Accessories Type Size Catalog no. Symmetrical 24" 36" 48" NSYMF24S CSP NSYMF36S CSP NSYMF48S CSP Asymmetrical 24" 36" 48" NASYF24S CSP NASYF36S CSP NASYF48S CSP AC1 CSP = spacer each. NAH3 CSP= twis tee each. AWG1W CSP = wire guard each. All symmetric and asymmetric reflectors are shipped separately from the fixture. Comprehensive lighting catalog 7th Edition 4.213 Linear recessed and surface lighting Catalog numbering logic Alter Please note that this ordering guide lists all Alter Soft Light numbering logic. The possible combinations and options do not apply to all luminaires. Please refer to the specific luminaire page. QVS 2 G Lumin. Ceiling width type Family QVC = Round Eclipse 1 = 12" QVE = Elegance 2 = 24" QVB = Slim Square 5 = 20" QMF = Metaform SR QVF = Slim Surface QVH = Slim SR QVS = Classic Classic OP Windows SmartVision Louver Metalyte Metalyte Louver QVW= Classic Wall Eclipse Wall Windows Wall QVL = Waves QVA = Air QHE = High-Efficiency QVD = Alter TileLyte QCE = Concept Elegance QCH = Concept SR QCJ = Concept PF OS Lamp shield with luminaire finish Lamp shield details GL = Glass Lamp Shield G = Grid S = Surface PA = Solid White Perimeter Lamp T = Slot T-grid Shield w/White Ceiling Mesh Center PC = Solid White Perimeter Lamp Shield w/White Mesh Inner Area and Solid center PF = Microperforated Mesh Lamp Shield PT = Metallic Reflector w/Microperforated Mesh Lamp Shield PG = Microperforated Mesh Lamp Shield w/Titanium Body PW= Microperforated Mesh Lamp Shield w/White Body SG = Solid Titanium Lamp Shield w/Titanium Body SW= Solid White Lamp Shield w/White Body 3 32 UNV H3 Lamp qty Lamp type Voltage Ballast 120 = 120V 277 = 277V UNV= 120-277V BF = 2 lamps Elec. Add appropriate 55W TT5 suffix to Cat. no. BP = 2 lamps Elec. 50W TT5 DA = iGEN DALI DS = iGEN BroadCast 4 Sensor w/iGEN Ballast F4 = Electronic 18W QT 4pin O3 = 3 lamp Electronic T8 Instant start O4 = Electronic 4LPB T8 Instant start PA = PowerSpec HDF dimming Electronic 18W TT5 PB = PowerSpec HDF dimming Electronic 40W TT5 PC = PowerSpec HDF dimming Electronic 50/55W TT5 PD = Electronic Dimming 2x42W TTT 4 pin PG = Electronic T5 Program start PS = PowerSpec HDF dimming Electronic T8 SB = 2 lamps Electronic 40W TT5 SO = 2 lamp Electronic T8 Instant start TC = Electronic 2x32W TTT 4 pin TD = Electronic 2x42W TTT 4 pin X3 = 3 lamps 40W Electronic TT5 HI = Electronic T8 <10THD H3 = 1-3 lamp Electronic T8 <10THD H4 = 1-4 lamp Electronic T8 <10THD AD = Asymmetric 1 = 1 lamp Distribution 2 = 2 lamp CB = Circular lamp 3 = 3 lamp shield 4 = 4 lamp GB = Clear acrylic w/Blue projected color face GC = Clear acrylic GG = Clear acrylic w/Green projected color face GR = Clear acrylic w/Red projected color face LG = Grey solid flat blade louver LV = White perforated flat blade louver LW = White solid flat blade louver OP = One-Piece lamp shield OB = One-piece lamp shield w/Sensor OS = Open Slot (no acrylic) SQ = Square Windows basket SS = Lateral Wave side shields SR = Lateral Curved side shields 14 = 2' T5 14W 17 = 2' T8 17W 24 = 2' T5HO 24W 32 = 4' T8 32W FT = TT5 FL = Two TT5 in 2' x TT = TTT Triple Tube 28 = 4' T5 28W 54 = 4' T5HO 54W QT= Quad QT lamp 4' A Options Catalog numbering logic Coffaire (recessed) Please note that this ordering guide lists all coffaire luminaire numbering logic. The possible combinations and options do not apply to all luminaires. Please refer to the specific luminaire page. CF S Family Body style CF = Coffaire A = Air supply and return S = Static H= Air return 4.214 Philips Lightolier 2 Lumin. width 1 = 12" 2 = 24" G PF 2 32 UNV HI Lamp qty Lamp type Voltage Ballast Ceiling type Shielding G = Both Standard Grid and Slot Grid N = 9/16" Narrow T-Grid PF = Perforated 1 = 1 lamp Mesh Shield 2 = 2 lamp HP= High performance 3 = 3 lamp SQ= Acrylic Lens and Perforated Steel Center Panel 120 = 120V 14 = 2' T5 14W 17 = 2' T8 17W 277 = 277V 24 = 2' T5HO 24W UNV= 120-277V FT= TT5 28 = 4' T5 28W 32 = 4' T8 32W 54 = 4' T5HO 54W A Options HI = Electronic T8 Add appropriate Instant start suffix to Cat. no. H3= 1-3 lamp Elec. T8 Instant start PG= Electronic T5 Program start PR= Electronic TT5 (40W) Program start BP= 2 lamps Elec. 50W TT5 P2 = Electronic T8 Program start P3 = 1-3 lamp Elec. T8 Program start I3 = 1-3 lamp Elec. TT5 (40W) Instant start For complete specification information visit www.lightolier.com Linear recessed and surface lighting Catalog numbering logic Parabolic (recessed and surface) Please note that this ordering guide lists all parabolic luminaire numbering logic. The possible combinations and options do not apply to all luminaires. Please refer to the specific luminaire page. DP Family A Body style 2 G Lumin. Ceiling width type DP = Deepcel A = Air supply 1 = 12" Plus and return 2 = 24" VR = Vision S = Static 6 = 6" Smart B = Surface box Recommended ST = Stacklyte LI = Lytecel Individual LC = Lytecel Continuous G = Grid (lay-in T bar) T = Slot grid or two-directional concealed T (see options) F = Flange for drywall, plaster or concealed splice S = Surface 18 Number of cells L Louver finish 8 = 1x8 (1' x 4') L = Low iridescence 9 = 3x3 (2' x 2') Semi12 = 2x6 (2' x 4') specular 3x4 (2' x 2') P = L ow 1x12 (1x4') iridescence 16 = 4x4 (2' x 2') Specular 2x8 (2' x 4') 18 = 3x6 (2' x 4') 20 = 1x20 (6' x 48') 24 = 2x12 (1' x 4') 3x8 (2' x 4') 27 = 3x9 (2' x 4') 29 = 2x9 (2' x 4') 32 = 4x8 (2' x 4') 3 32 UNV Mounting method S Lamp qty Lamp type H3 Voltage for ballast cover louver S = Single P = Twin R = Specular reflector in a lumin. cross section 1 = 1 lamp 2 = 2 lamp 3 = 3 lamp 4 = 4 lamp 17 = 2' T8 120 = 120V 20 = 2' T12 277 = 277V 32 = 4' T8 UNV= 120-277V 2U= T8U1.6 6U= T8U6 or T12U6 FT= TT5 Ballast A Options SO = Electronic T8 Add appropriate suffix to Cat. no. O3 = 1-3 lamp Electronic T8 O4 = 1-4 lamp ElectronicT8 SB = Electronic 40W TT5 X3 = 1-3 lamp Electronic 40W TT5 PS = LOL PowerSpec T8 Dimming PB = LOL PowerSpec 40W TT5 Dimming HI = Electronic T8 <10THD H3 = 1-3 lamp Electronic T8 <10THD H4 = 1-4 lamp Electronic T8 <10THD Catalog numbering logic Lens (recessed and surface) except XP troffer Please note that this ordering guide lists all lens luminaire numbering logic. The possible combinations and options do not apply to all luminaires. Please refer to the specific luminaire page. SP Family S Body style SP = SpecPlus A = Air supply PR = Prismalyte S = Static Plus B = Surface box SU = Operating Room Luminaire PN= Prismalyte Box SL = SL Surface box 2 G FS VA 4 32 UNV Voltage Ballast 120 = 120V 277 = 277V UNV= 120-277V SO = Electronic T8 Add appropriate suffix to Cat. no. O3 = 1-3 lamp Electronic T8 O4 = 1-4 lamp ElectronicT8 SB = Electronic 40W TT5 X3 = 1-3 lamp Electronic 40W TT5 PS = LOL PowerSpec T8 Dimming PB = LOL PowerSpec 40W TT5 Dimming HI = Electronic T8 <10THD H3 = 1-3 lamp Electronic T8 <10THD H4 = 1-4 lamp Electronic T8 <10THD Lumin. Ceiling width type Lens frame Lens/shield type Lamp qty Lamp type 1 = 12" 2 = 24" FS= Flat steel frame RA= Regressed aluminum frame FA= Flat aluminum frame iridescence RF= Regressed aluminum floating door VA= Standard (virgin acrylic see options and consult factory) in a lumin. cross section 1 = 1 lamp 2 = 2 lamp 3 = 3 lamp 4 = 4 lamp 6 = 6 lamp 17 = 2' T8 20 = 2' T12 32 = 4' T8 2U= T8U1.6 6U= T8U6 or T12U6 FT= TT5 G = Grid (lay-in T bar) F = Flange for drywall, plaster or concealed splice S = Surface H4 A Options Comprehensive lighting catalog 7th Edition 4.215 Linear recessed and surface lighting Surface/wall Options & accessories Radio interference filter Cord and plug convenience RF = Inductive capacitor circuit designed to minimize interference from line radiation or feedback. 120V or 277V, 50 or 60 Hz. One per fixture. e.g: WA4A232120SO RF CPA (120V) CPB (277V) = Factory wired six foot 3-conductor cord with a heavy-duty twist-lock plug with proper NEMA configuration for specified voltage. Twist tee hanger Wire guards Stem and canopy set NAH3 CSP (SW/KW fixtures) NAH3D CSP (SD/KD fixtures) AWG1W CSP (SN strip) AWG3W CSP (SW/SD strip) For SW/SD/KW/KD installation of 4 ⅛" wide (channel) fixture on exposed “T” grid ceilings on hard surfaces. Provides 1 ½" clearance from surface. Hinge and latch positive-lock construction, complete with longitudinal and transverse struts for secure protection. Baked White Enamel. ASC6 CSP (6") ASC12 CSP (12") ASC18 CSP (18") ASC24 CSP (24") Fusing Row couplers Canopy spacer (1 ½") A = Internal fast-blow fusing. NHDC-W CSP (SD/SW fixtures) AC1 CSP C = Internal slow-blow fusing. Required to connect, stabilize stem or chain-mounted fixtures used in continuous rows. Suspends fixture approximately 1 ½" from surface. e.g: WA4A232120SO A 4.216 Philips Lightolier e.g: WA4A232120SO CPA Fluorescent emergency lighting system Chain hanger kit EM = Factory-installed emergency power battery pack with charger and inverter, B100 or equal, 120V or 277V. Two 5' heavy duty chains with sturdy “V” hooks that grip fixtures at four knock-out points for level suspension. AH5 CSP (SW/SD/KW/KD fixtures) e.g: WA4A232120SO EM Heavy duty slide-grip hanger NAHD CSP (SD/KD fixtures) NAHW CSP (SW/KW fixtures) Suspends fixture 6", 12", 18" or 24" from surface and can be used in conjunction with Heavy-Duty Slide Grip Hanger. Hinge and latch positive-lock construction, complete with longitudinal and transverse struts for secure protection. For complete specification information visit www.lightolier.com Linear recessed and surface lighting Industrial Options & accessories Radio interference filter Cord and plug convenience RF = Inductive capacitor circuit designed to minimize interference from line radiation or feedback. 120V or 277V, 50 or 60 Hz. One per fixture standard. e.g: TU4A232120S0 RF CPA (120V) CPB (277V) = Factory wired six foot 3-conductor cord with a heavy-duty twist-lock plug with proper NEMA configuration for specified voltage. Twist tee hanger Wire guards Stem and canopy set NAH3 CSP (SW/KW fixtures) NAH3D CSP (SD/KD fixtures) AWG4W CSP (KD/KW fixtures) LFL - 173 (TU fixtures) For SW/SD/KW/KD installation of 4 ⅛" wide (channel) fixture on exposed “T” grid ceilings on hard surfaces. Provides 1 ½" clearance from surface. Hinge and latch positive-lock construction, complete with longitudinal and transverse struts for secure protection. ASC6 CSP (6") ASC12 CSP (12") ASC18 CSP (18") ASC24 CSP (24") Fusing Row couplers Canopy spacer (1 ½") Reflector row aligners A = Internal fast-blow fusing. NHDC-W CSP (KD/KW fixtures) AC1 CSP KND CSP C = Internal slow-blow fusing. Required to connect, stabilize stem or chain-mounted fixtures used in continuous rows. Suspends fixture approximately 1 ½" from surface. Clear, tough, plastic aligners for KW/KD fixture reflectors. e.g: TF4A232120S0 A e.g: TU4A232120S0 CPA Fluorescent emergency lighting system Chain hanger kit EM = Factory-installed emergency power battery pack with charger and inverter, B100 or equal, 120V or 277V. Two 5' heavy duty chains with sturdy “V” hooks that grip fixtures at four knock-out points for level suspension. AH5 CSP (KW/KD fixtures) e.g: TU4A232120SO EM Heavy duty slide-grip hanger Suspends fixture 6', 12', 18' or 24' from surface and can be used in conjunction with Heavy-Duty Slide Grip Hanger or Ice-Tong Hanger. NAHD CSP (KD fixtures) NAHW CSP (KW fixtures) LFL - 111 (TU fixtures) Hinge and latch positive-lock construction, complete with longitudinal and transverse struts for secure protection. Reflector row aligners Housing row couplers TU - SNA (TU fixtures) LFL - 3 (TU fixtures) Aluminum joiners clamp reflectors together for straight, permanent alignment. Two aligners are included with all 8' fixtures. For continuous row installations, specify two additional bulkpacked aligners per reflector point. Comprehensive lighting catalog 7th Edition 4.217 Linear recessed and surface lighting Drywall kit For most recessed fixtures “F” Mounting frame assembly Features ⅛" Dia. Screw Assembly Hole ¼" Dia. Wire Hanger Hole 6"x48", 1' x 4', 2' x 2', 2' x 4' • Designed to permit use of grid (NEMA G) fixtures in ceilings requiring flanges. For Mounting in Drywall or Ceilings Requiring Flanges • May be used with any “G” type Philips Lightolier troffer. 1 ½" 1 ⅜" • May be used in conjunction with Philips Lightolier plaster frame. 1 ⅛" • Extruded aluminum construction with mitered corners. " 3 16 • Includes screws for complete assembly. • Not for continuous row mounting. Ordering information Catalog number Fixture Size FK906X4 FK91X4 FK92X2 FK92X4 6" X 48" 1' x 4' 2' x 2' 2' x 4' Ceiling (cut out) Opening A B 6 ⅝" (168mm) 12 ⅝" (321mm) 24 ⅝" (626mm) 24 ⅝" (626mm) 48 ⅝" (1235mm) 48 ⅝" (1235mm) 24 ⅝" (626mm) 48 ⅝" (1235mm) 48 ⅝" 49 516" 25 " 5 16 6 ⅝" OR 12 ⅝" 25 516" Mounting methods for “F” mounting frame assembly Wire Hangers (by others) Fixture Note: Do not use wire hangers (by others) at end of fixture. Wire Hangers (by others) Fixture “F” Mounting Frame Plaster Frame “F” Mounting Frame Channel (by others) Acoustical Tile (by others) Plaster (by others) Acoustical Tile (by others) 1 ⅛" Note: Do not use wirer hangers (by others) at end of fixture. Fixture “F” Mounting Frame 1 ⅛" 1 ⅛" Note: Do not use wirer hangers (by others) at end of fixture. Note: Do not use wirer hangers (by others) at end of fixture. “F” Mounting frame assembly installation instructions Ceiling cut out dimensions 1. Assemble “F” 2. Install “F” mounting mounting frame with screws supplied (4 places). Wire Hangers (by others) frame into ceiling opening. “F” Mounting Frame May be used with plaster frame. Install fixture into “F” mounting frame. Ceiling Opening A B Screws (supplied) “F” Mounting Frame Assemble “F” mounting frame with supplied screws (4 places). 4.218 Philips Lightolier “F” Mounting Frame Install “F” mounting frame into ceiling opening. May be used with plaster frame (see reverse side for mounting methods). For complete specification information visit www.lightolier.com Linear recessed and surface lighting The ULM module Motion or light sensor enclosure The Universal Light and Motion (ULM) Module sensor integrates with recessed lighting fixtures. The clean design allows it to blend in nicely with the ceiling system and lighting fixture. The ULM Module is an enclosure that will accommodate most manufacturers motion or daylight sensors in either line or low voltage. It is designed to interface and quick connect to most of our 2x4 and 2x2 recessed lighting fixtures. The ULM Module creates the convenience of being able to build a motion or daylight sensor (produced by others) into any of our recessed fixtures eliminating the potential errors in how the sensors and fixtures are electrically connected. The ULM Module comes packaged complete with the appropriate sensor and can be easily installed and connected to the end of the lighting fixture. Note: Fixtures and ULM Modules are ordered as separate items. Sensors used and wiring of fixtures will be based on information provided by specifier. Features • Can accommodate most manufacturers light or occupancy sensor switch. • Line or low voltage. • Fits standard or slot grid ceiling systems. • Plug-in connection to mating fixture (ordered separately). • Secures to ceiling "T" (standard or slot grid). • Ceiling tile hold-down. • 18 gauge steel fascia. 6 ½" (165mm) Specifications Materials: 18 gauge cold rolled steel fascia. Finish: Flat white. Exposed Slot T-Grid Ceiling Exposed T-Grid Ceiling 4 ½" (114mm) Example 4" (102mm) UL 2 Housing: 24 gauge galvanized steel. Labels: I.B.E.W. F Fixture ULM Module width Finish Motion or Light 2 = 24" F = Flat Sensor Enclosure White Sensor code Manufacturer TR1 = Tridonic TR2 = Tridonic WS1 = Watt Stopper WS2 = Watt Stopper WS3 = Watt Stopper WS4 = Watt Stopper LU1 = Lutron LU2 = Lutron Manufacturer part number DSI Smart 120V DSI Smart 277V FS205 FS305 FS355 FS405 C-R-M1-WH C-SR-M1-WH Manufacturer Power rating 120V 120V 24VDC 24VDC 120-277VAC 24VDC 15VDC 15VDC Mates with 2' x 2' & 2' x 4' recessed fixture products Alter Classic (QVS) Alter High Efficiency (QHE) Alter Louver (QVS-LV) Coffaire (CF) Deepcel (DP) HP90 (H9) Opalescent (OP) Paraplus (PP) Prismalyte (PR) Skyway (SKS) The ULM Module clamps to the ceiling “T” bar and then the fixture is dropped in place. The same ULM Module will fit either standard or slot grid ceilings. Plug-in quick connectors are used for electrical connection of module to fixture. Housing encloses electrical connections — line or low voltage. Tile is notched and dropped in place. Specplus (SP) Vision Smart 2' x 2' (VR) Vision Smart 2' x 4' (VR) Comprehensive lighting catalog 7th Edition 4.219 Linear recessed and surface lighting Twin tube T5 ballast code options 22 ½" Long Ballast code options Example Example of voltage and ballast code fields to be populated within fixture specification sheet. Ballast code 1 2 3 Voltage 120 = 120V 277 = 277V UNV= 120-277V Ballast Ballast lamp capacity Type Ballast factor THD Voltage Wattage B3 1 - 3 Lamp Rapid Start 1.00 <10% 120 or 277 40W Ballast designation BA 3 1 or 2 Lamp Rapid Start 1.00 <10% UNV 18W Generic Electronic1 BB3 1 or 2 Lamp Rapid Start 0.95 <10% UNV 24W Generic Electronic1 BF3 1 or 2 Lamp Program start 1.00 <10% UNV 55W Generic Electronic1 BP 3 1 or 2 Lamp Program Rapid Start 0.98 <10% UNV 50W Generic Electronic1 CD Advance Electronic Centium Generic Electronic1 1 or 2 Lamp Instant start 0.88 <10% UNV 40W CE 1 - 3 Lamp Instant start 0.88 <10% UNV 40W Advance Electronic Centium CF 1 Lamp Program start 1.00 <10% UNV 40W Advance Electronic Centium IntelliVolt CT3 1 or 2 Lamp Program start 1.10 <10% UNV 50W or 55W Advance Electronic Centium IntelliVolt CY 1 - 3 Lamp Program Rapid Start 0.90 <10% UNV 50W or 55W Advance Electronic Centium IntelliVolt CZ 1 - 4 Lamp Program Rapid Start 0.90 <10% UNV 50W or 55W Advance Electronic Centium IntelliVolt I3 1 - 3 Lamp Instant start 0.88 <10% UNV 40W Generic Electronic1 IB3 1 or 2 Lamp Instant start 0.88 <10% UNV 40W Generic Electronic1 3 M7 1 - 2 Lamp Program start 1.00 / 0.03 <10% UNV 40W Advance Electronic Mark VII Dimming MW 3 1 or 2 Lamp Program start 0.90 / 0.03 <10% 120 or 277 55W Advance Electronic Mark VII Dimming MX 3 1 or 2 Lamp Program start 1.00 / 0.05 <10% 120 or 277 40W Advance Electronic Mark X Dimming MZ3 1 or 2 Lamp Program start 0.90 / 0.05 <10% 120 or 277 55W Advance Electronic Mark X Dimming P93 1 or 2 Lamp Program start 1.00 <10% UNV 55W Generic Electronic1 90°C PB 3 1 or 2 Lamp Program start 0.95 <10% UNV 40W Philips Lightolier Electronic Dimming PC3 1 or 2 Lamp Program start 0.90 <10% UNV 55W Philips Lightolier Electronic Dimming PR 3 1 or 2 Lamp Program Rapid Start 1.00 <10% UNV 40W Generic Electronic1 SB3 1 or 2 Lamp Instant start 1.00 <20% 120 or 277 40W Generic Electronic1 X3 1 - 3 Lamp Instant start 0.88 <20% 120 or 277 40W Generic Electronic1 Generic electronic ballast (Advance, Sylvania, Universal, UltraSave or GE) chosen by factory based on availability. Ballast factor based on 4' length lamps. Ballast code signifies use of a single 1 lamp ballast in a 2 lamp fixture, a single 1 lamp ballast and a 2 lamp ballast in a 3 lamp fixture and two 2 lamp ballasts in a 4 lamp fixture. 4.220 Philips Lightolier For complete specification information visit www.lightolier.com Linear recessed and surface lighting T8 ballast code options 2', 3' and 4' lengths Ballast code options Example Example of voltage and ballast code fields to be populated within fixture specification sheet. Ballast code Type Ballast factor2 THD Voltage A3 1 - 3 Lamp Program Rapid Start 0.71 <10% UNV A4 1 - 4 Lamp Program Rapid Start 0.71 <10% UNV Advance Electronic Optanium Low Watt A53 1 or 2 Lamp Instant start 0.77 <10% UNV Advance Electronic Optanium IOPA Low Watt A6 1 - 3 Lamp Instant start 0.77 <10% UNV Advance Electronic Optanium IOPA Low Watt A7 1 - 4 Lamp Instant start 0.77 <10% UNV Advance Electronic Optanium IOPA Low Watt C23 1 or 2 Lamp Instant start 0.87 <10% UNV Advance Electronic Optanium C3 1 - 3 Lamp Instant start 0.87 <10% UNV Advance Electronic Optanium C4 1 - 4 Lamp Instant start 0.87 <10% UNV Advance Electronic Optanium Advance Electronic Optanium Low Watt 1 or 2 Lamp Instant start 0.77 <10% UNV Advance Electronic Optanium Low Watt 1 - 3 Lamp Instant start 0.77 <10% UNV Advance Electronic Optanium Low Watt C7 1 - 4 Lamp Instant start 0.77 <10% UNV Advance Electronic Optanium Low Watt C8 1 - 3 Lamp Program Rapid Start 0.88 <10% UNV Advance Electronic Optanium C9 1 - 4 Lamp Program Rapid Start 0.88 <10% UNV Advance Electronic Optanium 1 or 2 Lamp Instant start 0.88 <10% UNV Advance Electronic Centium CG 1 or 2 Lamp Program Rapid Start 0.88 <10% UNV Advance Electronic Optanium CI 1 - 3 Lamp Instant start 0.88 <10% UNV Advance Electronic Centium CJ 1 - 4 Lamp Instant start 0.88 <10% UNV Advance Electronic Centium CK 3 1 or 2 Lamp Program Rapid Start 0.71 <10% UNV Advance Electronic Optanium Low Watt CO3 1 or 2 Lamp Instant start 1.18 <10% UNV Advance Electronic Optanium High Lite Output H3 1 - 3 Lamp Instant start 0.88 <10% UNV Generic Electronic1 3 H4 1 - 4 Lamp Instant start 0.88 <10% UNV Generic Electronic1 H5 1 - 2 Lamp & 1 - 4 Lamp Instant start 0.88 <10% UNV Generic Electronic1 H6 2 - 3 Lamp Instant start 0.88 <10% UNV Generic Electronic1 HI 1 or 2 Lamp Instant start 0.88 <10% UNV Generic Electronic1 1 - 3 Lamp Instant start 0.77 <10% UNV Generic Electronic1 Low Watt L4 1 - 4 Lamp Instant start 0.77 <10% UNV Generic Electronic1 Low Watt LW 3 1 or 2 Lamp Instant start 0.77 <10% UNV Generic Electronic1 Low Watt 3 L3 M4 1 - 4 Lamp (No 17W) Program start 0.88 <10% UNV Advance Electronic Mark VII Dimming M73 1 or 2 Lamp Program start 1.00 <10% UNV Advance Electronic Mark VII Dimming M8 1 - 3 Lamp Program start 0.88 <10% UNV Advance Electronic Mark VII Dimming MY 1 - 3 Lamp Program start 1.02 <10% P23 1 or 2 Lamp Program start 0.88 <10% UNV Generic Electronic1 P3 1 - 3 Lamp Program start 0.88 <10% UNV Generic Electronic1 1 - 4 Lamp Program start 0.88 <10% UNV Generic Electronic1 P4 PS 3 Ballast designation C6 3 CA 2 Ballast Ballast lamp capacity C5 1 Voltage 120 = 120V 277 = 277V UNV= 120-277V 120 or 277 Advance Electronic Mark X Dimming 1 or 2 Lamp Program start 0.98 <10% UNV Philips Lightolier Electronic Dimming PW 1 - 3 Lamp Program start 0.98 <10% UNV Philips Lightolier Electronic Dimming PX 1 - 4 Lamp Program start 0.98 <10% UNV Philips Lightolier Electronic Dimming V2 1 or 2 Lamp Program Rapid Start 0.95 <10% UNV Generic Electronic Step Dimming1 3 3 Generic electronic ballast (Advance, Sylvania, Universal, UltraSave or GE) chosen by factory based on availability. Ballast factor based on 4' length lamps. Ballast code signifies use of a single 1 lamp ballast in a 2 lamp fixture, a single 1 lamp ballast and a 2 lamp ballast in a 3 lamp fixture and two 2 lamp ballasts in a 4 lamp fixture. Comprehensive lighting catalog 7th Edition 4.221 Linear recessed and surface lighting T5 ballast code options 2', 3' and 4' lengths Ballast code options Example Example of voltage and ballast code fields to be populated within fixture specification sheet. 2 3 Ballast Ballast code Ballast lamp capacity Type Ballast factor THD Voltage AY 2 Lamp Program start 0.95 <10% UNV Advance Electronic Optanium Step Dimming (28 Watt Only) CT3 1 or 2 Lamp Program start 1.00 - 1.032 <10% UNV Advance Electronic Centium IntelliVolt CY 1 - 3 Lamp Program Rapid Start 1.00 <10% UNV Advance Electronic Centium IntelliVolt (54 Watt Only) CZ 1 - 4 Lamp Program Rapid Start 0.90 <10% UNV Advance Electronic Centium IntelliVolt (54 Watt Only) MW 3 1 or 2 Lamp Program start 1.00 / 0.03 <10% 120 or 277 Advance Electronic Mark VII Dimming (54 Watt Only) MZ3 1 or 2 Lamp Program start 1.00 / 0.052 <10% 120 or 277 Advance Electronic Mark X Dimming (24 or 54 Watt Only) P5 Ballast designation 1 - 3 Lamp Program start 1.00 <10% UNV Generic Electronic1 90°C (54 Watt Only) 3 1 or 2 Lamp Program start 1.00 <10% UNV Generic Electronic1 90°C (54 Watt Only) PF3 1 or 2 Lamp Program start 1.00 - 1.052 <10% UNV Philips Lightolier Electronic Dimming PG3 1 or 2 Lamp Program start 1.00 - 1.052 <10% UNV Generic Electronic1 PU 1 - 3 Lamp Program start 1.00 <10% UNV Generic Electronic1 (54 Watt Only) PV 1 - 4 Lamp Program start 1.00 <10% UNV Generic Electronic1 90°C (54 Watt Only) VY 2 lamp Program Rapid Start 0.95 <10% UNV Generic Electronic Step Dimming1 (14 or 28 Watt Only) VZ 1 or 2 Lamp Program Rapid Start 1.15 <10% UNV Generic Electronic Step Dimming1 (14 or 28 Watt Only) WA 3 1 or 2 Lamp Instant start 0.93 <10% WW 3 1 or 2 Lamp Program start 0.95 <10% UNV Generic Electronic1 (28 Watt Only) WX 1 or 2 Lamp Program start 1.15 <10% UNV Generic Electronic1 (28 Watt Only) P9 1 Voltage 120 = 120V 277 = 277V UNV= 120-277V 3 120 or 277 Generic Electronic1 (28 Watt Only) Generic electronic ballast (Advance, Sylvania, Universal, UltraSave or GE) chosen by factory based on availability. Ballast factor based on 4' length lamps. Ballast code signifies use of a single 1 lamp ballast in a 2 lamp fixture, a single 1 lamp ballast and a 2 lamp ballast in a 3 lamp fixture and two 2 lamp ballasts in a 4 lamp fixture. Deepcel 2' x 4' size Air handling data COMBINATION RETURN AIR/HEAT REMOVAL HEAT TRANSFER, ENERGY DISTRIBUTION, THREE LAMPS – FOUR LAMPS All performance data on the 2' x 4' luminaire is based on a maintained room temperature of 75°F (24°C). Air performance tests were conducted in accordance with Air Diffusion Council (ADC) air diffusing troffer heat removal test code TC-66. NEGATIVE STATIC PRESSURE (IN. OF H2O) Air return/heat transfer data for Deepcel 1. Input, BTUH 2. Heat removed; BTUH 3. Heat to space; BTUH 4.222 Philips Lightolier For complete specification information visit www.lightolier.com Linear recessed and surface lighting Air handling data Air return/heat transfer data for Deepcel & Lytecel Deepcel 2' x 2' size Heat transfer, energy distribution, two lamps All performance data on the 2' x 2' luminaire is based on a maintained room temperature of 75°F (24°C). Air performance tests were conducted in accordance with Air Diffusion Council (ADC) air diffusing troffer heat removal test code TC-66. 1. Input, BTUH 2. Heat removed; BTUH 3. Heat to space; BTUH VR 1' x 4' size NEGATIVE STATIC PRESSURE (IN. OF H2O) Heat transfer, energy distribution, two lamps Air handling data Air return through side slots All performance data on the 1' x 4' luminaire is based on a maintained room temperature of 75°F (24°C). Air performance tests were conducted in accordance with Air Diffusion Council (ADC) air diffusing troffer heat removal test code TC-66. Heat transfer, energy distribution, two F40 lamps 1. Input, BTUH 2. Heat removed; BTUH 3. Heat to space; BTUH NEGATIVE STATIC PRESSURE (IN. OF H2O) Air return/heat transfer data for VR *Lytecel 6" x 48" Air return Information Is only the Air return through the side slot. (No heat transfer data to right) Comprehensive lighting catalog 7th Edition 4.223 Linear recessed and surface lighting Air handling data Air return/heat transfer data for Prismalyte Plus 2' x 4' size 2' x 4' & 2' x 2' size All performance data on the 2' x 4' luminaire is based on a maintained room temperature of 75°F (24°C). Air performance tests were conducted in accordance with Air Diffusion Council (ADC) air diffusing troffer heat removal test code TC-66. 1. Input, BTUH 2. Heat removed; BTUH 3. Heat to space; BTUH 1' x 4' size 2' x 2' size All performance data on the 1' x 4' luminaire is based on a maintained room temperature of 75°F (24°C). Air performance tests were conducted in accordance with Air Diffusion Council (ADC) air diffusing troffer heat removal test code TC-66. All performance data on the 2' x 2' luminaire is based on a maintained room temperature of 75°F (24°C). Air performance tests were conducted in accordance with Air Diffusion Council (ADC) air diffusing troffer heat removal test code TC-66. 4.224 Philips Lightolier For complete specification information visit www.lightolier.com Linear recessed and surface lighting Air handling data Air return/heat transfer data for Paraplus and Coffaire 2' x 4' size 2' x 2' size Air performance tests on the 2' x 2' luminaire were conducted with procedure described in I.E.S. Journal, Summer 1987, Vol. 16, No. 2, Pages 21-31 by Building Acoustics Lighting Laboratories, Inc. Air performance tests on the 2' x 4' luminaire were conducted with procedure described in I.E.S. Journal, Summer 1987, Vol. 16, No. 2, Pages 21-31 by Building Acoustics Lighting Laboratories, Inc. Paraplus Coffaire Paraplus Coffaire Pressure drop tested in accordance with ADC 1062R2 Pressure drop tested in accordance with ADC 1062R2 .100 1. Input: BTUH. 2. Total to plenum: BTUH 3. Removed in exhaust BTUH. 1 Static Pressure-In. Wg. 300 200 100 20° Plenum to space two 54W T5HO Lamps 500 .010 300 200 100 3 0 -100 1 0 2 -100 2 -200 0 10 20 30 40 50 60 .010 1. Input: BTUH. 2. Total to plenum: BTUH 3. Removed in exhaust BTUH. 400 Static Pressure-In. Wg. 500 1. Return air through 8 heat slots 1/2" wide each inside lamp compartment. Static Pressure-In. Wg. Static Pressure-In. Wg. 20° Plenum to space two 54W T5HO lamps 400 .100 1. Return air through 20 heat slots 1/2" wide each inside lamp compartment. .001 10 CFM Through Lamp Compartment 20 30 40 50 70 100 150 200 250 Return Air Flow (CFM) 3 .001 -200 0 10 20 30 40 50 60 CFM Through Lamp Compartment 10 20 30 40 50 70 100 Return Air Flow (CFM) 1' x 4' size Air performance tests on the 1' x 4' luminaire were conducted with procedure described in I.E.S. Journal, Summer 1987, Vol. 16, No. 2, Pages 21-31 by Building Acoustics Lighting Laboratories, Inc. 20° Plenum to space two 54W T5HO lamps 500 1. Input: BTUH. 2. Total to plenum: BTUH 3. Removed in exhaust BTUH. Static Pressure-In. Wg. 400 300 Pressure drop tested in accordance with ADC 1062R2 Coffaire .100 Static Pressure-In. Wg. Paraplus 1. Return air through 20 heat slots 1/2" wide each inside lamp compartment. .010 Paraplus and Coffaire with air return meets the requirements of UL 1598, Paragraph 9.2.2.5, Large scale fallout tested in accordance with the fire test described in Paragraph 9.2.3.2.2., and is UL (Underwriters Laboratories) listed under File R5892, Vol. 1, Section 4, dated 11/16/2001. 200 100 0 -100 -200 0 10 20 30 40 50 60 CFM Through Lamp Compartment .001 10 20 30 40 50 70 100 150 200 250 Return Air Flow (CFM) Comprehensive lighting catalog 7th Edition 4.225
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.4 Linearized : Yes Tagged PDF : No XMP Toolkit : Adobe XMP Core 5.2-c001 63.139439, 2010/09/27-13:37:26 Modify Date : 2011:11:07 14:44:25-05:00 Create Date : 2011:11:07 14:44:25-05:00 Metadata Date : 2011:11:07 14:44:25-05:00 Format : application/pdf Document ID : uuid:ed950dbe-94d9-2b46-9c9f-f0d9c824514e Instance ID : uuid:bba0efbc-0aa8-404b-aa07-67620c4bcc0a Page Count : 228EXIF Metadata provided by EXIF.tools