NIPSCO 11 06 W Rep
111370-Catalog 111370-Catalog 111370-Catalog 784572 Batch6 unilog cesco-content
145938-Attachment 145938-Attachment 145938-Attachment 784572 Batch6 unilog cesco-content
317435-Catalog 317435-Catalog 317435-Catalog 784572 Batch7 unilog cesco-content
145938-Attachment 145938-Attachment 145938-Attachment 784572 Batch7 unilog cesco-content
252625-Catalog 252625-Catalog 252625-Catalog 784572 Batch7 unilog cesco-content
2014-06-03
: Pdf 242787-Attachment 242787-Attachment 784572 Batch4 unilog
Open the PDF directly: View PDF .
Page Count: 32
Download | |
Open PDF In Browser | View PDF |
Meter Mounting Equipment Northern Indiana Public Service Co. MILBANK OVERVIEW MILBANK OVERVIEW 2 Charles A. Milbank 1879-1966 Bill Martin Robert F. Waldrop, 1922-2002 Robert F. Waldrop, II Chairman Katrina Waldrop Henke Vice Chairman Milbank–Quality Metering Products for over 75 Years M ilbank Manufacturing Company was established in 1927 by Charles A. Milbank. Originally, the company manufactured high voltage switches; however, by 1941 Milbank devoted itself primarily to the manufacture of sheet metal enclosures and related equipment for the electrical generation and distribution industry. Today we are an industry leader in the manufacture of electrical meter sockets. Through a national network of manufacturer’s representatives we provide wholesale electrical distributors with quality electrical products for the utility, contractor, industrial and OEM markets. As the meter standards have changed, Milbank has been successful in adapting its product line to these changes. Our full scale engineering department designs products to meet customer specifications and satisfy all utility requirements. Milbank’s employee base of over 1,000 with our five manufacturing facilities comprising almost 550,000 square feet gives us the flexibility to schedule, produce, and ship orders quickly. Currently, Milbank manufactures over 10,000 different catalog items, and this list continues to grow. Our unique product offering includes: Residential & Commercial Meter Sockets; Residential & Commercial Meter Pedestals; RV/MH Power Outlets, Pedestals, and Transformers; Commercial & Industrial Electrical Enclosures; Circuit Breakers; Disconnects & Safety Switches; Safety Sockets; Utility & Residential Secondary Pedestals; Hubs and related accessories. If you don’t find a unit in this catalog to service your needs, send us your specifications and we will be happy to work with you. Our success has come from a loyal customer base that can rely on us to build quality products at 2 a fair price in a timely manner. Our willingness and ability to design and produce new products to meet our customer demands is an important factor to remain competitive in today’s electrical market. Milbank has been serving the electric utility & wholesale distribution industries for over 75 years with innovative, quality engineered products. So remember us for all of your meter mounting and related requirements, and we will be happy to serve you as we have in the past—with dependable service and quality products! We take great pride in being one of the few family-owned businesses left in our industry. We are a third generation run business and truly believe that... FAMILY MAKES A DIFFERENCE! TABLE OF CONTENTS DISCONNECTS AIR CONDITIONER DISCONNECT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5 AIR CONDITIONER DISCONNECT WITH GFCI RECEPTACLE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6 HOT TUB DISCONNECT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6 SINGLE POSITION (HORN BYPASS) 125 AMP–4 TERMINAL–RINGLESS –600 VAC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7 200 AMP–4 TERMINAL–RINGLESS–600 VAC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8 200 AMP–4 TERMINAL–SIDE WIREWAY–RINGLESS–600 VAC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8 SINGLE POSITION (LEVER BYPASS) 200 AMP–5 & 7 TERMINAL–HEAVY DUTY–RINGLESS–600 VAC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9 320 AMP–4 TERMINAL–HEAVY DUTY–RINGLESS–600 VAC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10 320 AMP CONTINUOUS–7 TERMINAL–HEAVY DUTY–RINGLESS–600 VAC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .11 MULTIPLE POSITION 100, 150 & 200 AMP / POSITION–4 TERMINAL–HORIZONTAL GANGS–RINGLESS–300 VAC . . . . . . . . . . . . . . . . .12 200 AMP / POSITION–7 TERMINAL–HORIZONTAL GANGS–HEAVY DUTY–RINGLESS–600 VAC . . . . . . . . . . . . . .13 CONDOMINIUM METERING BANKS 125 & 200 AMP / POSITION–VERTICAL & RECTANGULAR–120 / 240 VAC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .14-15 PEDESTALS 100 & 200 AMP–4 TERMINAL–RESIDENTIAL–SINGLE OR DOUBLE POSITION–RINGLESS-600 VAC . . . . . . . . . . .16 100 / 200 AMP–5 & 7 TERMINAL–LEVER BYPASS–HEAVY DUTY–600 VAC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .17 METER-MAIN / CIRCUIT BREAKERS 100 / 200 AMP–4 TERMINAL–CB MAIN DISCONNECT–RINGLESS–120 / 240 VAC . . . . . . . . . . . . . . . . . . . . . . . . . .18 100 / 200 AMP–4 TERMINAL–METER PEDESTAL–RINGLESS–PARALLEL MAIN–120 / 240 VAC . . . . . . . . . . . . . . .19 320 AMP–4 TERMINAL–WITH BREAKER–LEVER BYPASS–HEAVY DUTY–RINGLESS–120 / 240 VAC . . . . . . . . . .20 320 AMP–4 TERMINAL–NO BREAKER PROVISION–LEVER BYPASS–HEAVY DUTY–RINGLESS–600 VAC . . . . . .20 RV / MOBILE HOME PEDESTAL 200 AMP–4 TERMINAL–RINGLESS–120 / 240 VAC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .21 MISCELLANEOUS ACCESSORIES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .22-23 CONDUIT AND AMPACITY INFORMATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .24 ENERGIZATION OF ELECTRICAL EQUIPMENT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .25 MATERIALS AND FINISHES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .26 WATTHOUR METERS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .27 OTHER MILBANK PRODUCTS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .28 INDEX . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .29 3 TABLE OF CONTENTS CATALOG NUMBER LOGIC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4 3 CATALOG NUMBER LOGIC CATALOG NUMBER LOGIC 4 4 30 & 60 AMP–FUSIBLE / NON-FUSIBLE–AIR CONDITIONER DISCONNECTS 5 DISCONNECTS U3800 (No deadfront required) U3806 PROFILE Milbank’s air conditioner disconnect has a removable hinged cover which makes wiring a breeze. Our compact design meets all wire bending space requirements in the NEC and also complies with article 440-14 in the NEC. To insure the safest conditions, we designed our disconnect pullers to be removable or they may be reinstalled in the “off” position. Another safety feature is the padlock provision on the front cover. As with all Milbank products, our enclosure is constructed of G90U galvanized steel and finished with an attractive, light gray, baked powder coating. Our state of the art finish combines epoxy and polyester hybrid resins into a hybrid powder coating which is then electrostatically applied. This offers a durable, nonfading finish. TECHNICAL INFORMATION AMP TYPE CATALOG NUMBER MAX WT. H.P. # 30 FUSIBLE U3803 3 3.7 60 FUSIBLE U3806 10 3.7 U3800 10 3.25 60 NONFUSIBLE LINE & LOAD WIRE RANGE GROUND WIRE RANGE DIMENSIONS WIRE RATING CU °C CU AL CU/AL D″″ W″″ #14-#2 AWG #14-#2 AWG #14-#2 AWG #12-#2 AWG #12-#2 AWG #12-#2 AWG #12-2 AWG 3 5 91⁄4 60°/75° 60° #12-2 AWG 3 5 91⁄4 60°/75° 60° #14-4 AWG 3 5 U3800 is UL Listed without deadfront. Line and load terminations are fully insulated. U3800 std. quantity is 20 per carton. 5 H″″ 8 AL °C 60°/75° 60°/75° U3803 & U3806 std. quantity is 6 per carton. 30 & 60 AMP–FUSIBLE / NON-FUSIBLE–AIR CONDITIONER DISCONNECTS U3803 AC DISCONNECT / SPA BOX Combination AC Disconnect / 20 Amp GFCI Receptacle–Together in 1 Box AC DISCONNECT / SPA BOX DISCONNECTS 6 • Meets NEC # 210.63 Requirements * • UL Listed as Power Outlet • Type 3R Enclosure • In-Use Cover** • Duplex Ground Connector • 1” Concentric Knockouts * 60 amp, Non-Fused AC Disconnect AC DISCONNECT • 1∅, 240 Volt • 60 amp, Non-Fused Duplex 20 amp GFCI Receptacle Type 3R Enclosure with In-Use Cover GFCI RECEPTACLE • 20 amp • Reset/Test Button • Padlock provision U3822-20GR AMP 60 TYPE CATALOG MAX WT. NUMBER H.P. # NONFUSIBLE U3822-20GR 10 LINE & LOAD CONNECTOR WIRE RANGE 6 NEC® #210.63 Heating, AirConditioning and Refrigeration Equipment Outlet. ...The receptacle shall be located on the same level and within 7.5 m (25 ft.) of the heating, airconditioning and refrigeration equipment. * NEC® #210.08 Ground-Fault Circuit– Interruptor protection for personnel. GROUND CONNECTOR WIRE RANGE CU AL CU/AL #14-#2 AWG #12-#2 AWG #14-4 AWG DIMENSIONS WIRE RATING D″″ CU °C W″″ H″″ AL °C 4.8 5.25 7.4 60°/75° 60°/75° To ensure the safest conditions, Milbank disconnect pullers are designed to be reversible so they may be reinstalled in the OFF position. All units are designed with a padlock provision on the cover for security. **Note: U3822-20GR cover rated as IN-USE COVER (Cover may be closed with cords plugged into receptacle). *Reprinted with permission from NFPA 70-2002, National Electrical Code®, Copyright 2001, National Fire Protection Association, Quincy, MA 02269. This reprinted material is not the complete and official position of the NFPA on the referenced subject, which is represented only by the standard in its entirety. National Electrical Code® and NEC® are registered trademarks of the National Fire Protection Association, Quincy, MA. Hot Tub Disconnect or Sub Panel Breaker Enclosure–Type 3R Spa Box with GFCI Protection • • • • • • • • • • • 240 volt ground fault protection UL listed, Type 3R rainproof Milbank reliability Easy installation 2 pole, 50 amp GFCI breaker protection Compact size: 8-1/2” H x 7-1/2” W x 3-3/4” D 3 or 4 wire installation 1∅, 120 / 240 VAC Standard package of 12 2 extra one-pole breaker spaces 100 amp overall rating Sub Panel Breaker Enclosure • Use as a 100 amp, 4 circuit sub panel enclosure • U4881-O has provision for (2) 2-pole or (4) 1-pole small frame breakers U4881-O-50GB AMP TYPE CATALOG NUMBER WT. # U4881-O LINE & LOAD CONNECTOR WIRE RANGE GROUND CONNECTOR WIRE RANGE DIMENSIONS CU AL CU/AL D″″ W″″ H″″ 7 #14-1/0 #14-1/0 #14-1/0 3 3⁄4 71⁄2 81⁄2 50 BREAKER U4881-O-50GB 8 #14-1/0 #14-1/0 #14-1/0 3 3⁄4 71⁄2 81⁄2 60 BREAKER U4881-O-60GB 8 #14-1/0 #14-1/0 #14-1/0 3 3⁄4 71⁄2 81⁄2 – BREAKER PROVISION 6 125 AMP–4 TERMINAL–RINGLESS–600 VAC SINGLE POSITION 1 7 2 7487 5 125 AMP–4 TERMINAL–RINGLESS–600 VAC 3 4 4 6 U7487-RL-TG-KK ∅3W 125 AMP–4 TERMINAL*–RINGLESS–1∅ SERVICE AMP OH 125 CATALOG NUMBER DIMENSIONS HUB CONNECTORS BYCU/AL PASS D″″ W″″ H″″ U7487-RL-TG-KK H.O. #6-2/0 HORN 5 3 ⁄16 8 111⁄2 CONCENTRIC K.O.’S 1 2 3 4 5 1 1 2 11⁄4 — 1 ⁄2 1 ⁄2 6 1 ⁄4 HUBS: For proper hub selection see the hub suffix chart on the accessory page. BYPASS: The -KK horn type bypass is factory installed and permits changing and testing of the meter without interrupting customer service. CONNECTORS: Extruded aluminum connectors are tin plated. Units are supplied with duplex neutral. *FIFTH TERMINAL: For field mounted fifth terminal, order catalog number 5T24R. Utility requirements for this equipment may vary. Always consult the serving utility for their requirements before ordering or installing equipment in this catalog. 7 8 200 AMP–4 TERMINAL–RINGLESS–600 VAC 200 AMP–4 TERMINAL–RINGLESS–600 VAC SINGLE POSITION 1 1 2 4 2 4 3 55 7040 8949 6 7021 5 3 6 U7040-RL-TG-KK U7021-RL-TG-KK 1 3 2 1980 4 5 6 U1980-O-KK 200 AMP–4 TERMINAL–RINGLESS CONNECTORS CATALOG NUMBER SERVICE OH U8949-RL-TG-KK OH U7021-RL-TG-KK OH/UG U7040-RL-TG-KK BY- DIMENSIONS PASS D″″ W″″ H″″ CU/AL HUB LINE LOAD H.O. #6-350 kcmil #6-350 kcmil H.O. #6-350 kcmil #6-350 kcmil H.O. #6-350 kcmil #6-350 kcmil HORN HORN HORN 1 ⁄8 4 1 ⁄8 4 1 ⁄8 4 8 8 11 15 1 15 1 15 1 CONCENTRIC K.O.’S ⁄2 ⁄2 ⁄2 1 2 3 4 5 1 1 1 11⁄4 — 1 — 1 1 1 ⁄2 2 1 ⁄2 2 1 ⁄2 2 ⁄2 2 1 ⁄2 2 1 ⁄2 2 2 2 2 ⁄2 ⁄2 ⁄2 ⁄2 2 6 ⁄4 1 ⁄4 1 1 4, 2 ⁄ ⁄ 1 1 4, 2 1 ⁄ ⁄ ⁄4 HUBS: For proper hub selection see the hub suffix chart on the accessory page. FIFTH TERMINAL: For field mounted fifth terminal for U8949, U7021 & U7040, order catalog number K5T. CONNECTORS: Extruded aluminum connectors are tin plated. GROUND: For indoor service for U8949 order as extra catalog number BL1048-KK block assembly to be installed to provide insulated neutral. 200 AMP–4 TERMINAL–SIDE WIREWAY–RINGLESS CONNECTORS AMP SERVICE 200 UG CATALOG NUMBER U1980-O-KK LINE BLANK BY- DIMENSIONS PASS D″″ W″″ H″″ CU/AL HUB LOAD #6-350 kcmil #6-350 kcmil HORN 1 4 ⁄2 13 15 1 ⁄4 CONCENTRIC K.O.’S 1 2 1 1 2 ⁄2 2 ⁄2 3 4 5 6 3 1 1 1 1 4, 2 1 ⁄2 2 ⁄2 ⁄ ⁄ FIFTH TERMINAL: For factory installed fifth terminal in the 9 o’clock position add the suffix -5T. For field mounted fifth terminal order catalog number K5T. CONNECTORS: Extruded aluminum connectors are tin plated. Units are supplied with triplex neutral. Utility requirements for this equipment may vary. Always consult the serving utility for their requirements before ordering or installing equipment in this catalog. 8 200 AMP–5 & 7 TERMINAL–LEVER BYPASS–HEAVY DUTY–RINGLESS–600 VAC 9 6 1 3 SINGLE POSITION 5 2 9550 9700 6 2 3 9551 9701 U9701-O 4 U9550-RL 55 4 6 ∅3W 200 AMP–5 TERMINAL–RINGLESS–3∅ CONNECTORS AMP SERVICE CATALOG NUMBER 200 OH U9550-RL* 200 UG U9551-O* CU/AL HUB LINE LOAD BY- DIMENSIONS PASS D″″ W″″ H″″ 7 10 7 13 H.O. #6-350 kcmil #6-350 kcmil LEVER 4 BLANK LEVER 4 #6-350 kcmil #6-350 kcmil ⁄8 ⁄8 CONCENTRIC K.O.’S 1 2 1 3 1 2 19 3 2 1 18 ⁄2 ⁄2 ⁄2 3 4 5 3 — 1 1 4, 2 3 3 6 3 ⁄ ⁄ 1 ⁄4 ⁄4 1 1 4, 2 ⁄ ⁄ *Grounded B phase (may be field isolated). HUBS: For proper hub selection see the hub suffix chart on the accessory page. BYPASS: Lever supplies clamping action on meter spades and also operates bypass device. CONNECTORS: Units supplied with extruded aluminum connectors and bonded triplex ground. FIFTH TERMINAL: Fifth terminal is supplied in the 6 o’clock position. For factory installed fifth terminal in the 9 o’clock position add the suffix -5T9 to the catalog number. ∅4W 200 AMP–7 TERMINAL–RINGLESS–3∅ CONNECTORS AMP SERVICE CATALOG NUMBER 200 OH U9700-RRL 200 UG U9701-O CU/AL HUB LINE LOAD BY- DIMENSIONS PASS D″″ W″″ H″″ 7 10 7 13 H.O. #6-350 kcmil #6-350 kcmil LEVER 4 #6-350 kcmil #6-350 kcmil LEVER 4 BLANK ⁄8 ⁄8 CONCENTRIC K.O.’S 1 2 1 3 1 2 19 3 2 1 18 ⁄2 ⁄2 ⁄2 3 4 5 3 — 1 1 4, 2 3 3 ⁄ ⁄ 1 ⁄4 6 3 ⁄4 1 1 4, 2 ⁄ ⁄ HUBS: For proper hub selection see the hub suffix chart on the accessory page. BYPASS: Lever supplies clamping action on meter spades and also operates bypass device. CONNECTORS: Units supplied with extruded aluminum connectors and bonded triplex ground. INSULATED NEUTRAL: For field installed insulated neutral for the U9701 order kit number K1047. Utility requirements for this equipment may vary. Always consult the serving utility for their requirements before ordering or installing equipment in this catalog. 9 200 AMP–5 & 7 TERMINAL–LEVER BYPASS–HEAVY DUTY–RINGLESS–600 VAC 1 10 320 AMP–4 TERMINAL–LEVER BYPASS–HEAVY DUTY–RINGLESS–600 VAC 320 AMP–4 TERMINAL–LEVER BYPASS–HEAVY DUTY–RINGLESS–600 VAC SINGLE POSITION 3” KO–right side only 3000 2 1 4 3 5 1779 4 6 U1779-RRL (shown with optional hub installed) U3000-O-K3L-K2L ∅3W–600 VAC 320 AMP–4 TERMINAL–RINGLESS–1∅ CONNECTORS SERVICE UG OH CATALOG NUMBER U3000-O-K3L-K2L U1779-RRL CU/AL HUB LINE BLANK #4-600 kcmil (2) 1/0-250 kcmil 3/8″-16 H.O. STUD LOAD TWIN #6-350 kcmil 3/8″-16 STUD 5T KIT K3865 K3866 BY- DIMENSIONS PASS D″″ W″″ H″″ LEVER LEVER 7 4 ⁄8 7 4 ⁄8 15 30 13 3 38 ⁄4 CONCENTRIC K.O.’S 1 2 3 4 5 3 3 3 3 1 1 1 4, 2 3 1 3 1 1 1 4, 2 2 ⁄2 3 ⁄4 ⁄4 6 ⁄ ⁄ ⁄ ⁄ HUBS: For proper hub selection see the hub suffix chart on the accessory page. BYPASS: Lever supplies clamping action and also operates bypass device. CONNECTORS: Stud type units supplied with 3/8″-16 hex head nuts with Belleville washers. For connector kits, order as extra K1540 (600 kcmil). For twin lug connectors order as extra K1350 (350 kcmil). U3000-O-K3L-K2L uses K1540L (single 600) or K1350L (twin 350) non-rotating connectors for load side. Separate kits are required for both line and load. FIFTH TERMINAL: For factory installed fifth terminal in the 6 o’clock position add the suffix -5T6 to the catalog number. For factory installed fifth terminal in the 9 o’clock position at the suffix -5T9 to the catalog number. For field installed fifth terminal, order as extra K3865. Utility requirements for this equipment may vary. Always consult the serving utility for their requirements before ordering or installing equipment in this catalog. 10 320 AMP CONTINUOUS–7 TERMINAL–LEVER BYPASS–HEAVY DUTY–RINGLESS–600 VAC 11 320 AMP CONTINUOUS 400 AMP MAX. SINGLE POSITION 2 3 5 6 4 U2594-X-K7-INV (Shown without lugs) ∅4W 320 AMP–SIDE WIREWAY–7 TERMINAL–RINGLESS–3∅ CONNECTORS AMP SERVICE 320 OH/UG CATALOG NUMBER CU/AL HUB U2594-X-K7-INV C.P. LINE LOAD #4-600 kcmil 3/8″-16 STUD BY- DIMENSIONS PASS D″″ W″″ H″″ LEVER 1 6 ⁄2 19 34 1 ⁄8 CONCENTRIC K.O.’S 1 – 2 3 3 4 4 5 4 1 ⁄4 6 1 ⁄2,3⁄4,1 HUBS: For proper hub selection see the hub suffix chart on the accessory page. BYPASS: Lever supplies clamping action on meter spades and also operates bypass device. CONNECTORS: Type K7 single barrel 600 kcmil (catalog number K3441) line side lugs included. For load side lugs, stud type units are supplied with 3/8″-16 hex head nuts with Belleville washers. For single lug connector kits, order as extra K3441 (600 kcmil). For twin lug connectors order as extra K3442 (350 kcmil). . Utility requirements for this equipment may vary. Always consult the serving utility for their requirements before ordering or installing equipment in this catalog. 11 320 AMP CONTINUOUS–7 TERMINAL–LEVER BYPASS–HEAVY DUTY–RINGLESS–600 VAC 2594 12 100 & 200 AMP / POSITION–4 TERMINAL–HORIZONTAL GANG–RINGLESS–300 VAC 4″″ SIDE WIREWAY OH/UG SERVICE L572-XL-KK 100 & 200 AMP / POSITION–4 TERMINAL–HORIZONTAL GANG–RINGLESS 300 VAC MULTIPLE POSITION 1 4 5 U1252-X-KK (Shown with optional line side connectors) 2 1 3 3 1 1 1 2 1 2 1 1252 L572-6 4 5 3 5 6 5 1253-6 4 4 3 5 7 4 6 5 4 5 7 ∅3W–OVERHEAD–300 VAC 100 AMP / POSITION– 4 TERMINAL–RINGLESS–1∅ AMPS NO. OF POS. CATALOG NUMBER HUB 100 2 L572-XL-KK C.P. 100 3 L573-XL-KK C.P. 100 4 L574-XL-KK C.P. 100 5 L575-XL-KK C.P. 100 6 L576-XL-KK C.P. CONNECTOR CU/AL LINE #2-350 kcmil #2-350 kcmil #2-350 kcmil #2-350 kcmil #2-350 kcmil BY- DIMENSIONS PASS LOAD D″″ W″″ H″″ CONCENTRIC K.O.’S 1 2 3 4 5 #6-2/0 HORN 41⁄2 205⁄16 16 2 2 2 21⁄2 1 ⁄4,1⁄2 #6-2/0 HORN 41⁄2 281⁄2 16 2 2 2 21⁄2 1 #6-2/0 HORN 41⁄2 4011⁄16 16 2 2 2 21⁄2 1 #6-2/0 HORN 41⁄2 487⁄8 16 2 2 2 21⁄2 1 #6-2/0 HORN 41⁄2 571⁄16 16 2 2 2 21⁄2 1 ⁄4,1⁄2 ⁄4,1⁄2 ⁄4,1⁄2 ⁄4,1⁄2 CONNECTORS: Extruded aluminum connectors are tin plated. BUSSING: Supplied with 5/16″ x 1″ aluminum bussing. FIFTH TERMINAL: For field installed fifth terminal, order as extra catalog number 5T8K2 for the 6 o’clock position, and Kit #K9959 for the 9 o’clock position. EXTRA WIRE SPACE: Extra wire space of 4″ provided on the left end of 2 and 3 position gangs. Furnished on both ends of 4, 5, and 6 position gangs. MAIN BUS RATING: For main bus rating, see the conduit and ampacity information page in this catalog. BYPASS: The -KK horn type bypass is factory installed and permits changing and testing of the meter without interrupting customer service when used with utility-supplied jumpers. ∅3W–OH/UG–300 VAC 150 & 200 AMP / POSITION–4 TERMINAL–RINGLESS–1∅ NO. OF POS. CATALOG NUMBER HUB 2 U1252-X-KK* C.P. 3 U1253-X-KK* C.P. 4 U1254-X-KK* C.P. 5 U1255-X-KK* C.P. 6 U1256-X-KK* C.P. CONNECTOR CU/AL LINE BY- DIMENSIONS LOAD PASS D″″ W″″ H″″ 3/8″-16 STUD 3/8″-16 STUD 3/8″-16 STUD 3/8″-16 STUD 3/8″-16 STUD #6-350 kcmil #6-350 kcmil #6-350 kcmil #6-350 kcmil #6-350 kcmil HORN CONCENTRIC K.O.’S 1 2 3 4 14 21⁄2 21⁄2 3 ⁄8 34 ⁄16 14 21⁄2 21⁄2 16 21⁄2 ⁄8 54 ⁄8 16 51⁄8 261⁄2 1 11 HORN 5 HORN 51⁄8 427⁄8 1 7 HORN 5 HORN 51⁄8 637⁄8 18 5 6 7 21⁄2 1 1 1 3 21⁄2 1 1 1 21⁄2 3 21⁄2 1 1 1 21⁄2 21⁄2 3 21⁄2 1 1 1 21⁄2 21⁄2 3 21⁄2 1 1 1 ⁄2 ⁄2 ⁄2 ⁄2 ⁄2 ⁄4 ⁄4 ⁄4 ⁄4 ⁄4 HUB: For proper hub selection refer to the hub suffix chart on the accessory page. For the U1255 & U1256 units, two hub openings are supplied and the extra opening is closed with a closing plate as standard. FIFTH TERMINAL: For field mounted fifth terminal order catalog number K5T for 9 o’clock position. *CONNECTORS: Extruded aluminum connectors are tin plated. Units supplied with 3/8″–16 hex head nuts with Belleville washers on line side. Order connector kit K1541 (600 kcmil) as extra. BUSSING: Refer to the Conduit & Ampacity Section on page 25 of this catalog for information on ampacity of bussing. FOR OVERHEAD SERVICE: The U1254, U1255, and the U1256 units are factory assembled for underground service. If overhead service is desired an extension kit is required; order catalog number K3923 for the U1254 and U1255 units, and K3955 for the U1256 unit. For factory installed overhead service add suffix -EX to the catalog number. Utility requirements for this equipment may vary. Always consult the serving utility for their requirements before ordering or installing equipment in this catalog. 12 200 AMP / POSITION–7 TERMINAL–HORIZONTAL GANGS LEVER BYPASS–HEAVY DUTY–RINGLESS–600 VAC 1 1 1 3 4 5 13 2 4 CENTER WIREWAY MULTIPLE POSITION U2732-XT-PED (shown without pedestal) AMPS SERV. NO. OF POS. CATALOG NUMBER HUB 200 OH/UG 2 U2732-XT-PED (2)C.P. 200 OH/UG 3 U2733-XT-PED (2)C.P. 200 OH/UG 4 U2734-XT-PED (2)C.P. CONNECTOR CU/AL LINE LOAD 3/8″-16 STUD 3/8″-16 STUD 3/8″-16 STUD #6-350 kcmil #6-350 kcmil #6-350 kcmil BYPASS DIMENSIONS D″″ W″″ CONCENTRIC K.O.’S H″″ 1 2 3 4 5 PED 21⁄2 1 1 4, 2 6 321⁄8 251⁄4 21⁄2 21⁄2 LEVER 6 423 21 21 ⁄2 PED 21 ⁄2 1 1 4, 2 LEVER 6 521⁄4 251⁄4 21⁄2 21⁄2 PED 21⁄2 1 1 4, 2 LEVER ⁄16 251 ⁄4 ⁄2 ⁄ ⁄ ⁄ ⁄ ⁄ ⁄ HUBS: Units supplied with two closing plates. To order hubs as extra refer to the hub suffix chart on the accessory page. BYPASS: Lever supplies clamping action on meter spades and also operates bypass device. *CONNECTOR KITS: Line wire sections supplied with studs. For connector kits order K3082 (single-350 kcmil), K3441 (single600 kcmil), or twin K3442 (twin-350 kcmil) or K3083 (twin-600 kcmil.) Line connectors can be reversed to change from OH to UG service. *UNDERGROUND PEDESTALS: For underground service order S2291-TO pedestal raceway. A 12″ pedestal extension kit is also available. Order catalog number S2571. BUSSING: Bussing is 3/8″ x 1″ aluminum. Refer to the conduit & ampacity page of this catalog for information on ampacity of bussing. Utility requirements for this equipment may vary. Always consult the serving utility for their requirements before ordering or installing equipment in this catalog. 13 200 AMP / POSITION–7 TERMINAL–HORIZONTAL GANGS LEVER BYPASS–HEAVY DUTY–RINGLESS–600 VAC ∅4W–OVERHEAD / UNDERGROUND* 200 AMP –7 TERMINAL–RINGLESS–3∅ 14 CONDOMINIUM METERING BANKS–RINGLESS–OH/UG SERVICE–1∅3W–120 / 240 VAC U2864-X-PED-KK (Order breakers and pedestal raceway as extra) U2866-X (Shown without pedestal) ∅ VERTICAL—1∅ 200 AMP/POSITION CONDOMINIUM METERING BANKS–RINGLESS– OH/UG SERVICE–1∅3W–120 / 240 VAC CONDO MTR. BANKS 125 AMP/POSITION NO. OF POS. CATALOG NUMBER 2 U2852-X-KK-K1-PED 200 amp 3 U2853-X-KK-K1-PED 200 amp NO. OF POS. CATALOG NUMBER #6-350 kcmil 2 U2862-X-KK-K1-PED 250 amp #6-350 kcmil #6-350 kcmil 3 U2863-X-KK-K1-PED 300 amp #6-350 kcmil LINE MAIN BUS CONNECTOR RATING SIZE ∅ RECTANGULAR—1∅ 125 AMP/POSITION NO. OF POS. CATALOG NUMBER 4 U2854-X-KK-PED 400 amp 5 U2855-X-KK-PED 6 U2856-X-KK-PED SUFFIX 200 AMP/POSITION NO. OF POS. CATALOG NUMBER *3/8″-16 STUD 4 U2864-X-KK-PED 400 amp *3/8″-16 STUD 400 amp *3/8″-16 STUD 5 U2865-X-KK-PED 600 amp *3/8″-16 STUD 400 amp *3/8″-16 STUD 6 U2866-X-KK-PED 600 amp *3/8″-16 STUD LINE MAIN BUS CONNECTOR RATING SIZE KIT COMPATIBLE NUMBER WITH -K1 K1539 -K3 K1540 -K2 K1350 -K4 K1541 SINGLE TWIN U2852-56 U2862-66 U2854-56 U2864-66 U2854-56 U2863-66 U2864-66 LINE MAIN BUS CONNECTOR RATING SIZE *CONNECTORS: For line wire connector kits, order separately. FIFTH TERMINALS: For field mounted fifth terminal order catalog number K2381. Order one per meter position (9 o’clock position only). BREAKERS: Units have provision for one double pole main per meter position. Breakers not included, order as extra Milbank type Q or QNR or comparable. Refer to the accessories section in back of catalog. UNDERGROUND SERVICE: For underground service order S2291-TO pedestal raceway. Order separately. PEDESTAL EXTENSION KIT: A 12” pedestal extension kit is also available. Order catalog number S2571. CONNECTOR KITS * SIZE LINE MAIN BUS CONNECTOR RATING SIZE WIRE RANGE #6-350 kcmil #4-600 kcmil #6-350 kcmil #2-600 kcmil Utility requirements for this equipment may vary. Always consult the serving utility for their requirements before ordering or installing equipment in this catalog. 14 CONDOMINIUM METERING BANKS–RINGLESS–OH/UG SERVICE–1∅3W–120 / 240 VAC 15 CONDOMINIUM METERING BANKS VERTICAL with pedestal option in bottom 125 amp/pos. (2-3 position) 200 amp/pos. (2-3 position) D D 25" or 37" 29" or 41" U2852-X FIG. DIMENSIONS A 11⁄4 ″ CONCENTRIC K.O. B 1 ⁄4,1⁄2″ CONCENTRIC K.O. 3″ CONCENTRIC K.O. D 4″ HUB OPENING E 2″ CONCENTRIC K.O. 18" E E E PED 4-7/8" CONDO MTR. BANKS C 4-7/8" PED A A A 21" RECTANGULAR PEDESTAL OPTION PEDESTAL OPTION Pedestal Raceway S2291-TO Pedestal Extension Unit S2571 with pedestal option in bottom 125 amp/pos. (4,5 & 6 position) 200 amp/pos. (4,5 & 6 position) PED C 25" or 37" 29" or 41" A A A PED 31" A A A 4-7/8" E E E PED E E E 4-7/8" 36" FIFTH TERMINAL # K2381 (125-200 amp) Utility requirements for this equipment may vary. Always consult the serving utility for their requirements before ordering or installing equipment in this catalog. 15 CONDOMINIUM METERING BANKS–RINGLESS– OH/UG SERVICE–1∅3W–120 / 240 VAC C 16 100 / 200 AMP–4 TERMINAL–RESIDENTIAL PEDESTAL SINGLE OR DOUBLE POSITION–1∅3W–600 VAC 3 5 100 / 200 AMP–4 TERMINAL–RESIDENTIAL PEDESTAL SINGLE OR DOUBLE POSITION–1∅3W–600 VAC 1 3 2 2 2 GRADE LINE 4 18.00 U8436-O PEDESTALS Extension Unit K5800 ∅3W—600 VAC 100 / 200 AMP—4 TERMINAL—CECHA APPROVED—RINGLESS—1∅ CONNECTORS AMP SERVICE 200 UG CATALOG NUMBER U8436-O BLANK BY- DIMENSIONS PASS D″″ W″″ H″″ CU/AL HUB LINE LOAD 4/0 Crimp-On #6-350 kcmil HORN 1 4 ⁄8 9 62 CONCENTRIC K.O.’S 1 2 2 2 3 5 ⁄16 4 5 6 1 2 — ⁄2 HANGING HOOK: Supplied with keyhole hanger for easy mounting. EXTENSION UNIT: For 15” burial applications, order extension unit K5800; for 30” applications, order (2) K5800 units. FIFTH TERMINAL: For field installed fifth terminal, order catalog number K5T (9 o’clock position). BYPASS: Horn type bypass. Utility requirements for this equipment may vary. Always consult the serving utility for their requirements before ordering or installing equipment in this catalog. 16 100 / 200 AMP–5 & 7 TERMINAL–LEVER BYPASS–HEAVY DUTY PEDESTAL–600 VAC 4 4 17 PEDESTAL EXTENSION UNIT S3488 MILBANK 100 / 200 AMP–5 & 7 TERMINAL–LEVER BYPASS HEAVY DUTY PEDESTAL–600 VAC 1 3 2 4 4 4 4 9108 9107 U9107-O ∅-3W OR 3∅ ∅-3W 100 / 200 AMP—5 TERMINAL—HEAVY DUTY—1∅ # OF TERMS 5 CATALOG NUMBER U9108-O SERVICE UG HUB BLANK CONNECTORS CU/AL LINE LOAD BYPASS #6-350 kcmil LEVER 3/0-4/0 DIMENSIONS CONCENTRIC K.O.’S D″″ W″″ H″″ 1 2 3 6 11 58 21⁄2 21⁄2 21⁄2 4 5 ⁄16 — 5 # OF TERMS 7 CATALOG NUMBER U9107-O SERVICE UG HUB BLANK CONNECTORS CU/AL LINE LOAD BYPASS #6-350 kcmil LEVER 3/0-4/0 DIMENSIONS CONCENTRIC K.O.’S D″″ W″″ H″″ 1 2 3 6 11 58 21⁄2 21⁄2 21⁄2 4 5 ⁄16 — 5 BYPASS: Lever supplies clamping action on meter spades and also operates bypass device. BOTTOM PLATE: Bottom plate is not furnished with this unit. However, if plate is required, order catalog number S9157 as extra. NEUTRAL: The U9108-O is supplied with a center disconnect neutral. EXTENSION KIT: For direct burial applications, order kit S3488 as separate item. Utility requirements for this equipment may vary. Always consult the serving utility for their requirements before ordering or installing equipment in this catalog. 17 PEDESTALS ∅4W 100 / 200 AMP—7 TERMINAL—HEAVY DUTY—3∅ 18 100 OR 200 AMP–CIRCUIT BREAKER MAIN DISCONNECT–SINGLE POSITION METER MAIN–240 VAC M I L B A N K 2 1 100 OR 200 AMP–CIRCUIT BREAKER MAIN DISCONNECT SINGLE POSITION–METER MAIN–240 VAC 3 4 U7375-RL-KK U7607-RL-200-KK (Supplied with 200 Amp circuit breaker) ∅ 100 AMP–4 TERMINAL—METER MAIN (PLUG-IN)—RINGLESS—1∅ CATALOG NUMBER U7375-RL-KK SERVICE OH HUB H.O. CONNECTORS CU/AL LINE LOAD #6-2/0 BYPASS DIMENSIONS D″″ W″″ ⁄4 3 C.B. HORN 3 ⁄8 1 8 CONCENTRIC K.O.’S H″″ 1 22 1 1 2 ⁄4 3 ⁄4 1 1 ⁄4 1 1 4 5 ⁄ ⁄ — 1 1 4, 2 CIRCUIT BREAKER: Main circuit breaker not supplied with unit. For 100 amp service order Milbank catalog number Q2100 separately. See circuit breaker chart on accessory page for other compatible models. METER MAINS ∅ 200 AMP–4 TERMINAL—METER MAIN—RINGLESS—1∅ CATALOG NUMBER U7607-RL-200-KK SERVICE OH HUB H.O. CONNECTORS CU/AL LINE LOAD #6-350 #1-300 kcmil kcmil BYPASS DIMENSIONS D″″ ⁄2 1 HORN 4 W″″ ⁄8 1 8 H″″ 29 CONCENTRIC K.O.’S 1 2 2 2 3 4 5 2 1 1 4, 2 ⁄ ⁄ — CIRCUIT BREAKER: 200 amp main circuit breaker factory bussed. Order Milbank catalog number UQFB-200-X1 for replacement. Other amperages available. See Milbank circuit breaker chart on accessory page. HUBS: Order hubs separately–see accessory page for ordering information. FIFTH TERMINAL: For field mounted fifth terminal for U7375 order catalog number 5T8K2. For field mounted fifth terminal for U7607 order catalog number K5T. Mount in the 9 o’clock position only. Utility requirements for this equipment may vary. Always consult the serving utility for their requirements before ordering or installing equipment in this catalog. 18 100 / 200 AMP–4 TERMINAL–METER PEDESTAL–PARALLEL MAIN–1∅–120 / 240 VAC STD = 79" -LP = 70" 1 2 Grade Line STD = 36" -LP = 24" NU8980-O-KK ∅3W–UG–10K / 22K AIC RATING 100 / 200 AMP–4 TERMINAL–C/B–RINGLESS–1∅ CATALOG NUMBER W/ BREAKER INSTALLED HUB NU8980-O-100-KK BLANK NU8980-O-100-KK-LP BLANK NU8980-O-200-KK BLANK NU8980-O-200-KK-LP BLANK CONNECTOR CU/AL MAIN BREAKER DIMENSIONS CONCENTRIC K.O.’S BYPASS 10K 22K D″″ W″″ H″″ 1 2 3 LINE LOAD #6-350 KCMIL #6-350 KCMIL #6-350 KCMIL #6-350 KCMIL C/B HORN UQFP UQFPH 6 9 79 21⁄2 21⁄2 — C/B HORN UQFP UQFPH 6 9 70 21⁄2 21⁄2 — C/B HORN UQFP UQFPH 6 9 79 21⁄2 21⁄2 — C/B HORN UQFP UQFPH 6 9 70 21⁄2 21⁄2 — Utility requirements for this equipment may vary. Always consult the serving utility for their requirements before ordering or installing equipment in this catalog. 19 METER MAINS MAIN CIRCUIT BREAKERS: For 10K AIC order with factory installed main. For 22K AIC order pedestal without main and order circuit breaker separately. All main breakers are parallel connected. For series wired main order wire kit K4714 and UQFP-M type circuit breaker. See Milbank circuit breaker chart on accessory page. BRANCH CIRCUIT BREAKERS: Branch Interior accepts most manufacturers <100 amp. See plug-in breaker compatibility chart on accessory page. FIFTH TERMINAL: For field installed 5th terminal order 5T8K2. Mounts in 9 o'clock position only. BYPASS: All pedestals have horn-type bypass installed for meter testing or replacement without interrupting customer service. EXTENSION KIT: Available for low profile (-LP) units only. Order kit K4694. See accessory page. 100 / 200 AMP–4 TERMINAL–METER PEDESTAL–PARALLEL MAIN–1∅–120 / 240 VAC MILBANK 19 20 320 AMP–4 TERMINAL–METER MAIN–LEVER BYPASS–HEAVY DUTY–2/200 AMP CB 3 320 AMP CONTINUOUS 400 AMP MAX 3 320 AMP–4 TERMINAL–METER MAIN–LEVER BYPASS–HEAVY DUTY–2/200 AMP CB 4 4 1 1 2 2 M I L B A N K 1 3 2 Grade Line Grade Line Grade Line Grade Line 4 18" 4 18" 3 3 4-27/32" I.D. 13" O.D. 16-15/16" 15" U3849-O-2/200-INV S1848 Pedestal Extension Unit U1748-O-WI ∅3W 320 AMP–4 TERMINAL–METER MAIN WITH BREAKERS–RINGLESS–240 VAC–1∅ CATALOG NUMBER SERVICE HUB U3849-O-2/200-INV UG BLANK CONNECTORS CU/AL LINE LOAD 3/8″ X 16 STUDS DIMENSIONS BYPASS C.B. #1- 300 LEVER kcmil CONCENTRIC K.O.’S D″″ W″″ H″″ 1 2 47⁄8 13 64 21⁄2 21⁄2 3 4 5 ⁄16 — — 5 BREAKERS: Supplied from factory with 2 double-pole, 200 amp Milbank UQFB-200 or UQFBH-200 (22,000 AIC) bolt-on circuit breakers. * Must order 22K AIC breakers separately. Order Milbank UQFBH-200 breakers. CONNECTORS: The line wire section is supplied with 3/8”-16 studs with hex nuts and captive Bellville washers. For line side connectors, order as extra catalog numbers K1539 (single-350 kcmil), or K1540 (single-600 kcmil), or for twin K1350 (twin-350 kcmil). Order one kit per unit. EXTENSION KIT: For extension kit order as extra catalog number S1848. . METER MAINS ∅3W 320 AMP–4 TERMINAL–WITHOUT BREAKER PROVISION–RINGLESS–600 VAC–1∅ CATALOG NUMBER U1748-O-WI SERVICE UG HUB BLANK CONNECTORS CU/AL LINE LOAD 3/8″ X 16 STUDS TWIN #6350 kcmil BYPASS LEVER DIMENSIONS D″″ ⁄8 7 4 W″″ 13 CONCENTRIC K.O.’S H″″ 1 64 1 2 ⁄2 2 ⁄2 1 2 3 ⁄2 1 2 4 5 ⁄16 — 5 CONNECTORS: The line wire section is supplied with 3⁄8″–16 studs with hex head nuts and captive Belleville washers. The line side connectors are to be supplied by the Utility, load side is furnished. BYPASS: The lever supplies clamping action on the meter spade and also operates the bypass device. FIFTH TERMINAL: For field installed fifth terminal order kit number K3865. PEDESTAL EXTENSION KIT: If extension kit is required, order as extra kit number S1848. See accessory page. . Utility requirements for this equipment may vary. Always consult the serving utility for their requirements before ordering or installing equipment in this catalog. 20 200 AMP–SERIES U5136 & U5137–RINGLESS–METERED PEDESTAL U5136-O-200S SINGLE PEDESTAL CATALOG # U5136-O-100S U5136-O-200S U5136-O-200S/22 MAIN BREAKER UQFP-M-100 UQFP-M-200 UQFPH-M-200 AMPS 100 200 200 INTERIOR 4 Circuit 4 Circuit 4 Circuit WEIGHT (lbs) 82 82 82 DOUBLE PEDESTAL CATALOG # U5137-O-100S U5137-O-200S U5137-O-200S/22 MAIN BREAKER (2) UQFP-M-100 Series (2) UQFP-M-200 Series (2) UQFPH-M-200 Series AMPS 100 200 200 INTERIOR 4 Circuit 4 Circuit 4 Circuit WEIGHT (lbs) 115 115 115 RECEPTACLE / CIRCUIT BREAKER KITS AND ACCESSORIES (Sold separately) CATALOG # RECEPTACLE CIRCUIT BREAKER CONDUCTOR K5400-520 5-20R Duplex 20 amp, 1 Pole 12 Awg K5400-520GR 5-20R Duplex GFI 20 amp, 1 Pole 12 Awg K5400-TT30 TT30R 30 amp, 1 Pole 10 Awg K5400-1450 14-50R 50 amp, 2 Pole 8 Awg K5400-BRIDGE-1POS K5400-BRIDGE-2POS K5415 K5035 K5T K5193 CONFIGURATION GFI Rec. Self-grounded one position receptacle bridge with hardware Self-grounded two position receptacle bridge with hardware Stabilizer foot with hardware Pad mount kit with hardware (see note below) 5th terminal for 3 or 9 o’clock position Wire kit to convert series wired main breaker to parallel • A maximum of two receptacle / circuit breaker kits can be installed in each power head. Order from above. Other kits available. Consult factory for factory-installed receptacle kits. • Receptacle / circuit breaker kits include receptacle, circuit breaker, wire, cover plate and mounting screws. • Receptacle bridge K5400-BRIDGE-1POS or K5400-BRIDGE-2POS not included with pedestal. Order separately. • Pedestals are stocked with series wired main circuit breakers. Order K5193 kit to field convert to parallel main lug circuit breaker. For parallel wired main circuit breakers, change “S” suffix to “P” (Ex.: U5136-O-100P). • K5415 Stabilizer Foot sold separately. Recommended for double pedestals. • Pad mount pedestals available. Order U5138 (single meter) or U5139 (double meter) prefix. K5035 pad mount kit required. Order separately. 21 200 AMP–SERIES U5136 & U5137–RINGLESS–METERED PEDESTAL 24” RV/MH • UL Listed File E90945. • 200 amp maximum, 120/240 V, 1∅3W. • Ringless type meter socket with horn bypass and stainless steel latch. • Short circuit withstand rating 10K AIC, for 22K AIC, order with “22” suffix. • Type 3R construction for durable outdoor use. • Milbank grey polyester powder coat finish. • Wire terminations accept copper or aluminum conductors. • Line & Neutral: (2) #6-350 kcmil per phase. • Line Ground: (4) #14-1/0. • Load (CB): 1/0 to 300 kcmil per pole. • Load Neutral: (1) #6-350 kcmil. • Load Ground: (2) #14-1/0, (4) #14/6. • Commercial grade, plug-in main circuit breaker. Available in 100, 125, 150 & 200 amp. Type UQFP-M. • 4 circuit plated copper interior accepts (2) 2-pole or (4) 1-pole standard plug-in type circuit breakers. Branch circuit rated to 125 amps max. Acceptable manufacturers: Milbank, Cutler-Hammer, GE or Siemens. • Factory or field installable receptacle bridge and receptacle / circuit breaker kits available. See accessories. 21 22 MILBANK ACCESSORIES INTERCHANGEABLE UNIT HUBS MISC. HUB ADAPTER PLATE (Converts 4″ opening to 21⁄2″ opening) S8324 SMALL “RL"OPENING (STANDARD) SUFFIX SIZE 1″ WL YL ZL DL EL 11⁄4″ 11⁄2″ 2″ 21⁄2″ MILBANK NO. SUFFIX SIZE A7514 A7515 A7516 A7517 A7518 3″ F G H 31⁄2″ 4″ MILBANK NO. A8110 A8111 A8112 DESCRIPTION SUFFIX CAT. # STANDARD (for -RL opening) -XL A7551 LARGE (for -R opening) -X A9064 HUB SUFFIX CHART CLOSING COVERS MILBANK ACCESSORIES REMOVABLE HUB CLOSING PLATE LARGE “R” OPENING (HEAVY DUTY) O RL R XL X Plain Top Small Hub Opening Large Hub Opening Small Closing Plate Large Closing Plate Large Hub Opening RXL adapted to small Closing Plate METAL CLOSING PLATE METER CLOSING PLATE (for ringless sockets) (Grey Plastic) CP-21 6003 Large Hub Opening RRL adapted to small Hub Opening WL 1″ For -RL Opening YL 11⁄4″ For -RL Opening ZL 11⁄2″ For -RL Opening DL 2″ For -RL Opening EL 21⁄2″ For -RL Opening 3″ For -R Opening F G 31⁄2″ For -R Opening H 4″ For -R Opening PEDESTAL EXTENSION UNITS CATALOG NUMBER D″″ W″″ H″″ 3 4 1⁄8 4 7⁄8 6 8 ⁄16 11 10 13 9 15 15 12 15 24 4 1⁄8 9 15 1 S8988 S3488 S2571 S1848 K4694 K5800 4 ⁄2 6 #K3235 STAKE KIT Suitable for use with pedestals for extra support FOR CONDO METERING BANKS (125-200 AMP) K2381 FIFTH TERMINALS PLUG-IN FIFTH TERMINAL 5T8K2 (Fits in round hole of old style block) HEAVY DUTY JAW CLAMPING K3865 BOLT-IN FIFTH TERMINAL 5T24R (Fits in round hole of old style block) 22 FIFTH TERMINAL K5T (Fits in square hole of new style 200 amp block) MILBANK ACCESSORIES CONNECTOR KITS 23 DISCONNECT SLEEVE M5-144 For use with 3/8”-16 stud type units only TWIN SINGLE SUFFIX CATALOG # (3 per set) – 1 ∅ K1539 K3 K3L CATALOG # (4 per set) – 3 ∅ K5 K3082 K7 K3441 6-350 kcmil 4-600 kcmil or (2) 1/0-250 kcmil K1350 K2L K1350L K4 K1541 6-350 kcmil 6-350 kcmil Non-rotating 4-600 kcmil (4 per set) – 3 ∅ SUFFIX CATALOG # K6 K8 ISOLATED NEUTRAL KIT K1047 6-350 kcmil 4-600 kcmil K3442 K3083 MILBANK ACCESSORIES SUFFIX K2 LOAD TAP CONNECTORS (3 per set) Replaces the load side slide-in nut assembly on Milbank 200 amp sockets. Allows for a 100 amp tap location in addition to the #6-350 kcmil load-side connector. K5022 Includes Safety Barrier Extensions–for applications over 300 VAC. K4977-INT INTERNAL HEX K5022-INT INTERNAL HEX ANTI-INVERSION CLIP SEALING RINGS K4802 PLUG-IN BREAKER COMPATIBILITY CHART AMPS MILBANK 125-200 Q / QNR ≤ 100 CUTLER-HAMMER SIEMENS (WESTINGHOUSE) (ITE) SIEMENS MURRAY / CROUSE-HINDS G.E. SQ-D HQP / BR / WBJ Q / QN MD Q LINE — MP Q LINE HOMELINE QUICKLAG P / BR / HQP Q QP SCREW TYPE MR-4 BUCKLE HASP MR-8 MILBANK 2-POLE—200 AMP LARGE FRAME—10,000 AIC & 22,000 AIC AMPS 10,000 AIC 22,000 AIC 10,000 AIC 22,000 AIC 10,000 AIC 22,000 AIC 10,000 AIC PLUG-IN PLUG-IN PLUG-IN PLUG-IN BOLT-ON BOLT-ON BOLT-ON 100 UQFP-100 UQFPH-100 UQFP-M-100 UQFPH-M-100 UQFB-100 UQFBH-100 UQFB-100-X1 125 UQFP-125 UQFPH-125 UQFP-M-125 UQFPH-M-125 UQFB-125 UQFBH-125 UQFB-125-X1 150 UQFP-150 UQFPH-150 UQFP-M-150 UQFPH-M-150 UQFP-150 UQFBH-150 UQFP-150-X1 175 UQFP-175 UQFPH-175 UQFP-M-175 UQFPH-M-175 UQFB-175 UQFBH-175 UQFB-175-X1 200 UQFP-200 UQFPH-200 UQFP-M-200 UQFPH-M-200 UQFB-200 UQFBH-200 UQFB-200-X1 23 MISC. 6-350 kcmil 4-600 kcmil or K1540 (2) 1/0-250 kcmil 4-600 kcmil or K1540L (2) 1/0-250 kcmil Non-rotating K1 (3 per set) – 1 ∅ SUFFIX CATALOG # 24 CONDUIT AND AMPACITY INFORMATION MAXIMUM NUMBER OF CONDUCTORS IN CONDUIT* CONDUCTOR SIZE AWG,MCM TYPE CONDUIT AND AMPACITY INFORMATION MISC. RHW & RHH (without outer covering) THW TW THW FEPB (6 thru 2), RHW and RHH (without outer covering) RH, THHW CONDUIT TRADE SIZES (INCHES) 1 ⁄4 1 11⁄4 11⁄2 2 21⁄2 3 ⁄2 31⁄2 3 4 14 12 10 8 6 4 4 1 10 8 6 3 16 13 11 5 29 24 19 10 40 32 26 13 65 53 43 22 93 76 61 32 143 192 117 157 95 127 163 49 66 85 6 1 2 3 7 10 16 23 36 48 62 3 1 1 2 4 6 10 15 23 31 40 1 1 1 1 1 1 1 2 1 1 1 3 3 2 1 5 5 4 3 8 7 6 5 12 10 9 7 16 14 12 10 21 18 15 13 1 1 1 1 1 1 1 1 1 1 1 1 2 2 1 1 1 4 3 3 2 1 6 5 4 4 3 8 7 6 5 4 10 9 8 7 6 1 1 1 1 1 1 1 1 1 3 2 2 4 3 3 5 4 4 1/0 2/0 3/0 4/0 250 300 350 400 500 600 700 750 *This table is for concentric stranded conductors only. For cables with compact conductors refer to N.E.C. * ALLOWABLE AMPACITIES OF INSULATED COPPER & ALUMINUM CONDUCTORS (3W IN CONDUIT) 75°°C (167°°F) *CU AL or Cu-Clad AL A B A C 18 16 14 12 10 8 — — 20 25 35 50 — — — 12 10 8 — — — 20 30 40 6 4 3 2 1 65 85 100 115 130 6 4 3 2 1 50 65 75 90 100 1/0 2/0 3/0 4/0 150 175 200 230 1/0 2/0 3/0 4/0 120 135 155 180 250 300 350 400 500 255 285 310 335 380 250 300 350 400 500 205 230 250 270 310 600 700 750 420 460 475 600 700 750 340 375 385 AMPACITY CORRECTION FACTORS A = Size: AWG/MCM B = Ampere Rating for Insulation Types: FEPW, RH, RHW, THW, THWN, XHHW, USE, 2W. C = Ampere Rating for Insulation Types: RH, RHW, THW, THWN, XHHW, USE (Per NEC table 310-16) AMBIENT TEMP.C°° 21 - 25 26 - 30 31 - 35 36 - 40 41 - 45 46 - 50 51 - 55 56 - 60 61 - 65 66 - 70 CORRECTION FACTOR 1.05 1.00 .94 .88 .82 .75 .67 .58 .33 — AMBIENT TEMP.F°° 70 - 77 79 - 86 88 - 95 97 - 104 106 - 113 115 - 122 124 - 131 133 - 140 142 - 158 160 - 176 Overall ampere ratings of UL Listed Milbank multiple position meter sockets are based on 1993 N.E.C. Manual article 220-32 and ANSI / UL-414 (except where restricted by line connector size). These requirements provide for a diversity factor / demand factor being utilized in determining the overall (main bus / lug) rating of a gang socket. All Milbank UL Listed gang sockets meet or exceed these diversity factor/demand factor requirements. Standard overall ampacity ratings for UL Listed and non UL Listed gang sockets are as shown in the chart below. Ampere ratings of meter sockets are based on the meter socket being wired with 75° C insulated wire conductor, sized in accordance with Table 310-16 of the National Electric Code. GANG SOCKET OVERALL AMPACITIES NO. OF METER POSITIONS 2 3 4 5 6 100A / POS. AMPACITY 200A 200A 200A 225A 270A 125A / POS. AMPACITY 200A 225A 250A 285A 330A 150A / POS. AMPACITY 200A 225A 270A 338A 396A 200A / POS. AMPACITY 200A 270A 360A 450A 528A Unless otherwise permitted elsewhere in the Code, the overcurrent protection for conductor types marked with an obelisk () shall not exceed 15 amps for 14 AWG, 20 amps for 12 AWG, and 30 amps for 10 AWG copper: or 15 amps for 12 AWG and 25 amps for 10 AWG aluminum and copper-clad aluminum after any correction factors for ambient temperature and number of conductors have been applied. All meter sockets are 600 Volt rated unless otherwise noted. All meter socket ampacity ratings are continuous duty unless otherwise noted. 24 ENERGIZATION OF ELECTRICAL EQUIPMENT 25 IMPORTANT NOTE In addition to national and local electrical codes, many utilities have specific requirements for metering equipment. Always consult the serving utility for their specifications and requirements prior to ordering or installing Milbank meter mounting equipment. BEFORE ENERGIZING A. Use caution and follow established safety procedures: 1) Wear safety apparel. 2) Use safety equipment. 3) Take action to prevent injury to yourself and others in the event of failure of the installation. 4) Take action to prevent/decrease damage to property in the event of failure of the installation. 5) If you are unsure how to safely energize the installation, get someone who is knowledgeable to do it. AFTER ENERGIZING A. Secure the installation: 1) To prevent accidental contact with energized parts, cover all openings with approved filler devices. 2) To prevent unauthorized access, secure all covers and/or doors with approved security devices. 3) Attach/post information to advise others of potential hazards associated with the installation. RECOMMENDED TORQUE FOR GENERAL APPLICATIONS* JOINT DESCRIPTION NOMINAL SIZE SCREW NUT 10 10 10 12 12 1/4 1/4 5/16 5/16 3/8 1/2 BRASS STEEL STEEL STEEL STEEL STEEL STEEL STEEL STEEL STEEL STEEL Brass Nut or Extruded Hole CU or AL Busbar <1/8″ Steel Nut or EH; CU or AL Busbar >1/8″ Aluminum Extruded Hole Steel Nut or Extruded Hole Aluminum Extruded Hole Steel Nut or EH; CU or AL Busbar Aluminum Extruded Hole Steel Nut or EH; CU or AL Busbar Steel Nut Steel Nut HEAD TYPE TORQUE ( INCH LBS. ) ALL ALL ALL ALL ALL ALL ALL HEX HEX HEX HEX 20-25 in. lbs. 25-30 in. lbs 30-35 in. lbs 30-35 in. lbs 40-50 in. lbs. 40-50 in. lbs. 50-60 in. lbs. 60-70 in. lbs. 100-150 in. lbs. 150-200 in. lbs. 200-250 in. lbs. *Interior labels typically indicate the required torque for wire connectors and studs, and should be referenced first. EH: Extruded Hole CU: Copper AL: Aluminum 25 ENERGIZATION OF ELECTRICAL EQUIPMENT WHEN ENERGIZING MISC. A. Give equipment a thorough visual examination to determine that: 1) No shipping or installation damage exists. 2) Proper clearances have been maintained. 3) All connections have been made. 4) Equipment is clean and dry. B. Make a thorough examination to verify: 1) Tightness of all bolted connections (see table below). 2) Manually operate all circuit breakers, switches, relays, etc. 3) Check rigidity of all mountings, bus bars and components. 4) Use test equipment to check continuity of circuitry and integrity of insulation. C. All switches and circuit breakers should be in the “off” position. D. Verify that manual meter bypass (if applicable) is in non-bypass position. E. Install cover and/or close doors. F. If installation is not being energized at this time, follow “after-energizing” steps listed below. These steps will secure the installation in case of accidental energization. 26 MATERIALS AND FINISHES MATERIALS STEEL QUALITY The meter equipment listed in this catalog is made of galvanized steel (AISI* G90) to afford the best possible weather proofing. *American Iron and Steel Institute. MISC. STEEL SHEET 16 gauge, galvanized, sheet: 1 1/4 oz./ sq.ft. class zinc-coated. (AISI G90) 14 gauge, galvanized, sheet: 1 1/4 oz./ sq.ft. class zinc-coated. ALUMINUM EXTRUSION Wire-Terminals: Alloy; 6061-T6, Tin-plated for CU/AL wire. Bus Bar: Alloy; 6101-o & 6063-O MATERIALS AND FINISHES ALUMINUM SHEET 3000 series aluminum sheet, H14, or 5052 series aluminum sheet, H32. Where applicable thicknesses range from .064 — .125 COPPER SHEET & BUS Electrolytic copper with tin plating in most applications. INSULATING MATERIALS • In most units, support bases for current-carrying components are molded from fiberglass reinforced high-strength, track resistant, thermoset polyester molding compounds. • Clear or black safety shields and polarity barriers are molded from high-strength, track resistant, polycarbonate molding compounds. • Various sheet insulating materials, as appropriate for the application are utilized in the fabrication of flat, formed and punched component parts and barriers. FINISH PROCESS Light gray “state of the art” electrostatically applied powder paint offers a durable, non-fading finish. For further information concerning the chemical analysis of the weather resistant finish, please contact the factory. METAL FASTENERS Zinc-coated with a chromate dip. RATING NEMA RATING All Milbank meter sockets, CT cans and meter socket / breaker units have a Type 3R rating. 26 WATTHOUR METERS–STANDARD FORMS–TRANSFORMER RATED OR SELF-CONTAINED SC 2 and 3-WIRE FORMS 1S & 2S SC 2 and 3-WIRE FORMS 1S & 2S with BYPASS TR TR 2-WIRE FORM 3S 5th Term. 9 o'clock 2-WIRE FORM 3S with BYPASS 27 TR 2-WIRE FORM 3S 5th Term.6 o'clock MISC. SC SC SC 2-WIRE FORM 3S with BYPASS 2 ELEMENT 3-WIRE NETWORK FORM 12S 5th TERM. 9 o'clock 2 ELEMENT 3-WIRE NETWORK FORM 12S with BYPASS 5th Term. 9 o'clock 2 ELEMENT 3-WIRE NETWORK FORM 12S 5th TERM. 6 o'clock TR TR SC 3-WIRE FORM 4S 3-WIRE FORM 4S WITH BYPASS 2 or 3 ELEMENT 3∅4W Y or Δ Y FORM 14S Δ FORM 15S SC 2 or 3 ELEMENT 3∅4W Y or Δ FORMS 14S & 15S with BYPASS SC 2 ELEMENT 3-WIRE NETWORK FORM 12S with BYPASS 5th Term. 6 o'clock TR 2 ELEMENT 3∅4W Y or Δ Y FORM 7S Δ FORM 24S with BYPASS TR TR SC SC TR 2 ELEMENT 2∅3W, 2∅4W, 3∅3W FORM 5S 2 ELEMENT 2∅3W, 2∅4W, 3∅3W FORM 5S with BYPASS 2 ELEMENT 2∅3W, 2∅4W, 3∅3W FORM 13S 2 or 3 ELEMENT 2∅3W, 2∅4W, 3∅3W FORM 13S with BYPASS 2 or 3 ELEMENT 3∅4W Y or Δ Y FORM 9S Δ FORM 8S TR TR TR 2 ELEMENT 3∅4W Y FORM 6S 2 ELEMENT 3∅4W Y FORM 6S with BYPASS TR = TRANSFORMER RATED SC = SELF CONTAINED 2 or 3 ELEMENT 3∅4W Y or Δ FORMS 8S & 9S with BYPASS Utility requirements for this equipment may vary. Always consult the serving utility for their requirements before ordering or installing equipment in this catalog. 27 WATTHOUR METERS–STANDARD FORMS–TRANSFORMER RATED OR SELF-CONTAINED TR 28 ADDITIONAL MILBANK PRODUCTS ADDITIONAL MILBANK PRODUCTS MISC Other quality products available from Milbank In addition to your local utility’s meter mounting equipment, Milbank also manufactures supporting products, such as... Air Conditioner Disconnects Hot Tub Disconnects RV/Mobile Home Power Outlets Terminal Boxes Temporary Power Outlets Commercial Pedestals Commercial Enclosures CT Enclosures Circuit Breakers Distribution Unit Substations Enclosed Circuit Breakers Safety Switches Test Switches Contact your local distributor or go to www.milbankmfg.com to find additional product literature. 28 INDEX PG CAT. NO. PG CAT. NO. PG 6003 . . . . . . . . . . . . . . . . . . . . . . . . .22 MR-4 . . . . . . . . . . . . . . . . . . . . . . . . .23 U7021-RL-TG-KK . . . . . . . . . . . . . . . .8 5T24R . . . . . . . . . . . . . . . . . . . . . . . .22 MR-8 . . . . . . . . . . . . . . . . . . . . . . . . .23 U7040-RL-TG-KK . . . . . . . . . . . . . . . .8 5T8K2 . . . . . . . . . . . . . . . . . . . . . . . .22 NU8980-O-100-KK . . . . . . . . . . . . . .19 U7375-RL-KK . . . . . . . . . . . . . . . . . .18 A7514 . . . . . . . . . . . . . . . . . . . . . . . .22 NU8980-O-100-KK-LP . . . . . . . . . . .19 U7487-RL-TG-KK . . . . . . . . . . . . . . . .7 A7515 . . . . . . . . . . . . . . . . . . . . . . . .22 NU8980-O-200-KK . . . . . . . . . . . . . .19 U7607-RL-200-KK . . . . . . . . . . . . . .18 A7516 . . . . . . . . . . . . . . . . . . . . . . . .22 NU8980-O-200-KK-LP . . . . . . . . . . .19 U8436-O . . . . . . . . . . . . . . . . . . . . . .16 A7517 . . . . . . . . . . . . . . . . . . . . . . . .22 S1848 . . . . . . . . . . . . . . . . . . . . . . . .22 U8949-RL-TG-KK . . . . . . . . . . . . . . . .8 A7518 . . . . . . . . . . . . . . . . . . . . . . . .22 S2291-TO . . . . . . . . . . . . . . . . . . . . .15 U9107-O . . . . . . . . . . . . . . . . . . . . . .17 A7551 . . . . . . . . . . . . . . . . . . . . . . . .22 S2571 . . . . . . . . . . . . . . . . . . . . .15, 22 U9108-O . . . . . . . . . . . . . . . . . . . . . .17 A8110 . . . . . . . . . . . . . . . . . . . . . . . .22 S3488 . . . . . . . . . . . . . . . . . . . . . . . .22 U9550-RL . . . . . . . . . . . . . . . . . . . . . .9 A8111 . . . . . . . . . . . . . . . . . . . . . . . .22 S8324 . . . . . . . . . . . . . . . . . . . . . . . .22 U9551-O . . . . . . . . . . . . . . . . . . . . . . .9 A8112 . . . . . . . . . . . . . . . . . . . . . . . .22 S8988 . . . . . . . . . . . . . . . . . . . . . . . .22 U9700-RRL . . . . . . . . . . . . . . . . . . . . .9 A9064 . . . . . . . . . . . . . . . . . . . . . . . .22 U1252-X-KK . . . . . . . . . . . . . . . . . . .12 U9701-O . . . . . . . . . . . . . . . . . . . . . . .9 CP-21 . . . . . . . . . . . . . . . . . . . . . . . .22 U1253-X-KK . . . . . . . . . . . . . . . . . . .12 UQFB-100 . . . . . . . . . . . . . . . . . . . . .37 K1047 . . . . . . . . . . . . . . . . . . . . . . . .23 U1254-X-KK . . . . . . . . . . . . . . . . . . .12 UQFB-100-X1 . . . . . . . . . . . . . . . . . .37 K1350 . . . . . . . . . . . . . . . . . . . . .14,23 U1255-X-KK . . . . . . . . . . . . . . . . . . .12 UQFB-125 . . . . . . . . . . . . . . . . . . . . .37 K1350L . . . . . . . . . . . . . . . . . . . . . . .23 U1256-X-KK . . . . . . . . . . . . . . . . . . .12 UQFB-125-X1 . . . . . . . . . . . . . . . . . .37 K1539 . . . . . . . . . . . . . . . . . . . . .14, 23 U1748-O-WI . . . . . . . . . . . . . . . . . . .20 UQFB-150 . . . . . . . . . . . . . . . . . . . . .37 K1540 . . . . . . . . . . . . . . . . . . . . .14, 23 U1779-RRL . . . . . . . . . . . . . . . . . . . .10 UQFB-150-X1 . . . . . . . . . . . . . . . . . .37 K1540L . . . . . . . . . . . . . . . . . . . . . . .23 U1980-O-KK . . . . . . . . . . . . . . . . . . . .8 UQFB-175 . . . . . . . . . . . . . . . . . . . . .37 K1541 . . . . . . . . . . . . . . . . . . . . .14, 23 U2594-X-K7-INV . . . . . . . . . . . . . . . .11 UQFB-175-X1 . . . . . . . . . . . . . . . . . .37 K2381 . . . . . . . . . . . . . . . . . . . . .15, 22 U2732-XT-PED . . . . . . . . . . . . . . . . .13 UQFB-200 . . . . . . . . . . . . . . . . . . . . .37 K3082 . . . . . . . . . . . . . . . . . . . . . . . .23 U2733-XT-PED . . . . . . . . . . . . . . . . .13 UQFB-200-X1 . . . . . . . . . . . . . . . . . .37 K3083 . . . . . . . . . . . . . . . . . . . . . . . .23 U2734-XT-PED . . . . . . . . . . . . . . . . .13 UQFBH-100 . . . . . . . . . . . . . . . . . . .37 K3235 . . . . . . . . . . . . . . . . . . . . . . . .22 U2852-X-KK-K1-PED . . . . . . . . . . . .14 UQFBH-125 . . . . . . . . . . . . . . . . . . .37 K3441 . . . . . . . . . . . . . . . . . . . . . . . .23 U2853-X-KK-K1-PED . . . . . . . . . . . .14 UQFBH-150 . . . . . . . . . . . . . . . . . . .37 K3442 . . . . . . . . . . . . . . . . . . . . . . . .23 U2854-X-KK-PED . . . . . . . . . . . . . . .14 UQFBH-175 . . . . . . . . . . . . . . . . . . .37 K3865 . . . . . . . . . . . . . . . . . . . . . . . .22 U2855-X-KK-PED . . . . . . . . . . . . . . .14 UQFBH-200 . . . . . . . . . . . . . . . . . . .37 K4509 . . . . . . . . . . . . . . . . . . . . . . . .23 U2856-X-KK-PED . . . . . . . . . . . . . . .14 UQFP-100 . . . . . . . . . . . . . . . . . . . . .37 K4694 . . . . . . . . . . . . . . . . . . . . . . . .22 U2862-X-KK-K1-PED . . . . . . . . . . . .14 UQFP-125 . . . . . . . . . . . . . . . . . . . . .37 K4695 . . . . . . . . . . . . . . . . . . . . . . . .22 U2863-X-KK-K1-PED . . . . . . . . . . . .14 UQFP-150 . . . . . . . . . . . . . . . . . . . . .37 K5035 . . . . . . . . . . . . . . . . . . . . . . . .21 U2864-X-KK-PED . . . . . . . . . . . . . . .14 UQFP-175 . . . . . . . . . . . . . . . . . . . . .37 K5086 . . . . . . . . . . . . . . . . . . . . . . . .22 U2865-X-KK-PED . . . . . . . . . . . . . . .14 UQFP-200 . . . . . . . . . . . . . . . . . . . . .37 K5193 . . . . . . . . . . . . . . . . . . . . . . . .21 U2866-X-KK-PED . . . . . . . . . . . . . . .14 UQFPH-100 . . . . . . . . . . . . . . . . . . .37 K5400-1450 . . . . . . . . . . . . . . . . . . .21 U3000-O-K3L-K2L . . . . . . . . . . . . . .10 UQFPH-125 . . . . . . . . . . . . . . . . . . .37 K5400-520 . . . . . . . . . . . . . . . . . . . .21 U3800 . . . . . . . . . . . . . . . . . . . . . . . . .5 UQFPH-150 . . . . . . . . . . . . . . . . . . .37 K5400-520GR . . . . . . . . . . . . . . . . . .21 U3803 . . . . . . . . . . . . . . . . . . . . . . . . .5 UQFPH-175 . . . . . . . . . . . . . . . . . . .37 K5400-BRIDGE-1POS . . . . . . . . . . .21 U3806 . . . . . . . . . . . . . . . . . . . . . . . . .5 UQFPH-200 . . . . . . . . . . . . . . . . . . .37 K5400-BRIDGE-2POS . . . . . . . . . . .21 U3822-20GR . . . . . . . . . . . . . . . . . . . .6 UQFPH-M-100 . . . . . . . . . . . . . . . . .37 K5400-TT30 . . . . . . . . . . . . . . . . . . .21 U3849-O-2/200-INV . . . . . . . . . . . . .20 UQFPH-M-125 . . . . . . . . . . . . . . . . .37 K5415 . . . . . . . . . . . . . . . . . . . . . . . .21 U4881-O . . . . . . . . . . . . . . . . . . . . . . .6 UQFPH-M-150 . . . . . . . . . . . . . . . . .37 K5800 . . . . . . . . . . . . . . . . . . . . . . . .22 U4881-O-50GB . . . . . . . . . . . . . . . . . .6 UQFPH-M-175 . . . . . . . . . . . . . . . . .37 K5T . . . . . . . . . . . . . . . . . . . . . . .21, 22 U4881-O-60GB . . . . . . . . . . . . . . . . . .6 UQFPH-M-200 . . . . . . . . . . . . . . . . .37 L572-XL-KK . . . . . . . . . . . . . . . . . . .12 U5136-O-100S . . . . . . . . . . . . . . . . .21 UQFP-M-100 . . . . . . . . . . . . . . . . . .37 L573-XL-KK . . . . . . . . . . . . . . . . . . .12 U5136-O-200S . . . . . . . . . . . . . . . . .21 UQFP-M-125 . . . . . . . . . . . . . . . . . .37 L574-XL-KK . . . . . . . . . . . . . . . . . . .12 U5136-O-200S/22 . . . . . . . . . . . . . . .21 UQFP-M-150 . . . . . . . . . . . . . . . . . .37 L575-XL-KK . . . . . . . . . . . . . . . . . . .12 U5137-O-100S . . . . . . . . . . . . . . . . .21 UQFP-M-175 . . . . . . . . . . . . . . . . . .37 L576-XL-KK . . . . . . . . . . . . . . . . . . .12 U5137-O-200S . . . . . . . . . . . . . . . . .21 UQFP-M-200 . . . . . . . . . . . . . . . . . .37 M5-144 . . . . . . . . . . . . . . . . . . . . . . .23 U5137-O-200S/22 . . . . . . . . . . . . . . .21 29 INDEX CAT. NO. 29 NOTES NOTES 30 30 NOTES 31 NOTES 31 Meter Mounting Equipment & More! Commercial Electrical Enclosures Residential & Commercial Metering Commercial Meter Pedestals Disconnect Devices Current Transformer Enclosures RV/MH Pedestals Temporary Power Outlets Circuit Breakers Distribution Unit Substations Enclosed Circuit Breakers Safety Switches Test Switches REPRESENTATIVE Callas/Kingsley 845 Lively Boulevard Wood Dale, IL 60191 Tel: 630-595-7887 Fax: 630-595-6922 www.ckelectricalsales.com MILBANK MFG. CO. PO Box 419028 Kansas City, MO 64141-0028 Tel: 816-483-5314 Fax: 816-483-6357 Toll Free: 877-483-5314 www.milbankmfg.com www.milbankmfg.com NIPSCO 11/06 (1K)
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.6 Linearized : No XMP Toolkit : 3.1-701 Producer : Acrobat Distiller 7.0.5 for Macintosh Create Date : 2006:11:27 10:58:50-06:00 Modify Date : 2007:01:11 16:52:24-06:00 Creator Tool : QuarkXPress: pictwpstops filter 1.0 Metadata Date : 2007:01:11 16:52:24-06:00 Format : application/pdf Title : NIPSCO 11 06 w rep Creator : Melisa J Burns Document ID : uuid:9ee8819a-7e38-11db-94ba-000a95b001fc Instance ID : uuid:67492f3a-a1c6-11db-8f9a-000a95b001fc Has XFA : No Page Count : 32 Author : Melisa J BurnsEXIF Metadata provided by EXIF.tools