Meter Mounting Equipment
Northern Indiana Public Service Co.

MILBANK OVERVIEW

MILBANK OVERVIEW

2

Charles A. Milbank
1879-1966

Bill Martin

Robert F. Waldrop,
1922-2002

Robert F. Waldrop, II
Chairman

Katrina Waldrop Henke
Vice Chairman

Milbank–Quality Metering Products for over 75 Years

M

ilbank Manufacturing
Company was established in 1927 by
Charles A. Milbank.
Originally, the company manufactured high voltage switches;
however, by 1941 Milbank devoted itself primarily to the manufacture of sheet metal enclosures
and related equipment for the
electrical generation and distribution industry. Today we are an
industry leader in the manufacture of electrical meter sockets.
Through a national network of
manufacturer’s representatives we
provide wholesale electrical distributors with quality electrical
products for the utility, contractor,
industrial and OEM markets.
As the meter standards have
changed, Milbank has been successful in adapting its product
line to these changes. Our full
scale engineering department
designs products to meet customer specifications and satisfy
all
utility
requirements.

Milbank’s employee base of over
1,000 with our five manufacturing facilities comprising almost
550,000 square feet gives us the
flexibility to schedule, produce,
and ship orders quickly.
Currently, Milbank manufactures
over 10,000 different catalog
items, and this list continues to
grow. Our unique product offering includes: Residential &
Commercial Meter Sockets;
Residential & Commercial Meter
Pedestals; RV/MH Power Outlets,
Pedestals, and Transformers;
Commercial
&
Industrial
Electrical Enclosures; Circuit
Breakers; Disconnects & Safety
Switches; Safety Sockets; Utility &
Residential Secondary Pedestals;
Hubs and related accessories. If
you don’t find a unit in this catalog to service your needs, send us
your specifications and we will
be happy to work with you.
Our success has come from a
loyal customer base that can rely
on us to build quality products at

2

a fair price in a timely manner.
Our willingness and ability to
design and produce new products
to meet our customer demands is
an important factor to remain
competitive in today’s electrical
market.
Milbank has been serving the
electric utility & wholesale distribution industries for over 75
years with innovative, quality
engineered products. So remember us for all of your meter
mounting and related requirements, and we will be happy to
serve you as we have in the
past—with dependable service
and quality products!
We take great pride in being
one of the few family-owned
businesses left in our industry.
We are a third generation run
business and truly believe that...

FAMILY MAKES A
DIFFERENCE!

TABLE OF CONTENTS

DISCONNECTS
AIR CONDITIONER DISCONNECT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5
AIR CONDITIONER DISCONNECT WITH GFCI RECEPTACLE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6
HOT TUB DISCONNECT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6

SINGLE POSITION (HORN BYPASS)
125 AMP–4 TERMINAL–RINGLESS –600 VAC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7
200 AMP–4 TERMINAL–RINGLESS–600 VAC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8
200 AMP–4 TERMINAL–SIDE WIREWAY–RINGLESS–600 VAC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8

SINGLE POSITION (LEVER BYPASS)
200 AMP–5 & 7 TERMINAL–HEAVY DUTY–RINGLESS–600 VAC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9
320 AMP–4 TERMINAL–HEAVY DUTY–RINGLESS–600 VAC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10
320 AMP CONTINUOUS–7 TERMINAL–HEAVY DUTY–RINGLESS–600 VAC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .11

MULTIPLE POSITION
100, 150 & 200 AMP / POSITION–4 TERMINAL–HORIZONTAL GANGS–RINGLESS–300 VAC . . . . . . . . . . . . . . . . .12
200 AMP / POSITION–7 TERMINAL–HORIZONTAL GANGS–HEAVY DUTY–RINGLESS–600 VAC . . . . . . . . . . . . . .13

CONDOMINIUM METERING BANKS
125 & 200 AMP / POSITION–VERTICAL & RECTANGULAR–120 / 240 VAC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .14-15

PEDESTALS
100 & 200 AMP–4 TERMINAL–RESIDENTIAL–SINGLE OR DOUBLE POSITION–RINGLESS-600 VAC . . . . . . . . . . .16
100 / 200 AMP–5 & 7 TERMINAL–LEVER BYPASS–HEAVY DUTY–600 VAC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .17

METER-MAIN / CIRCUIT BREAKERS
100 / 200 AMP–4 TERMINAL–CB MAIN DISCONNECT–RINGLESS–120 / 240 VAC . . . . . . . . . . . . . . . . . . . . . . . . . .18
100 / 200 AMP–4 TERMINAL–METER PEDESTAL–RINGLESS–PARALLEL MAIN–120 / 240 VAC . . . . . . . . . . . . . . .19
320 AMP–4 TERMINAL–WITH BREAKER–LEVER BYPASS–HEAVY DUTY–RINGLESS–120 / 240 VAC . . . . . . . . . .20
320 AMP–4 TERMINAL–NO BREAKER PROVISION–LEVER BYPASS–HEAVY DUTY–RINGLESS–600 VAC . . . . . .20

RV / MOBILE HOME PEDESTAL
200 AMP–4 TERMINAL–RINGLESS–120 / 240 VAC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .21

MISCELLANEOUS
ACCESSORIES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .22-23
CONDUIT AND AMPACITY INFORMATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .24
ENERGIZATION OF ELECTRICAL EQUIPMENT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .25
MATERIALS AND FINISHES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .26
WATTHOUR METERS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .27
OTHER MILBANK PRODUCTS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .28

INDEX . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .29

3

TABLE OF CONTENTS

CATALOG NUMBER LOGIC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4

3

CATALOG NUMBER LOGIC

CATALOG NUMBER LOGIC

4

4

30 & 60 AMP–FUSIBLE / NON-FUSIBLE–AIR CONDITIONER DISCONNECTS

5

DISCONNECTS

U3800
(No deadfront required)

U3806

PROFILE
Milbank’s air conditioner disconnect has a removable hinged cover which makes wiring a breeze. Our
compact design meets all wire bending space requirements in the NEC and also complies with article
440-14 in the NEC. To insure the safest conditions, we designed our disconnect pullers to be removable or they may be reinstalled in the “off” position. Another safety feature is the padlock provision on
the front cover. As with all Milbank products, our enclosure is constructed of G90U galvanized steel
and finished with an attractive, light gray, baked powder coating. Our state of the art finish combines
epoxy and polyester hybrid resins into a hybrid powder coating which is then electrostatically applied.
This offers a durable, nonfading finish.

TECHNICAL INFORMATION
AMP

TYPE

CATALOG
NUMBER

MAX WT.
H.P. #

30

FUSIBLE

U3803

3

3.7

60

FUSIBLE

U3806

10

3.7

U3800

10

3.25

60 NONFUSIBLE

LINE & LOAD
WIRE RANGE

GROUND
WIRE RANGE

DIMENSIONS

WIRE RATING
CU °C

CU

AL

CU/AL

D″″

W″″

#14-#2
AWG
#14-#2
AWG
#14-#2
AWG

#12-#2
AWG
#12-#2
AWG
#12-#2
AWG

#12-2 AWG

3

5

91⁄4 60°/75°

60°

#12-2 AWG

3

5

91⁄4 60°/75°

60°

#14-4 AWG

3

5



U3800 is UL Listed without deadfront. Line and
load terminations are fully insulated.



U3800 std. quantity is 20 per carton.



5

H″″

8

AL °C

60°/75° 60°/75°

U3803 & U3806 std. quantity is 6 per
carton.

30 & 60 AMP–FUSIBLE / NON-FUSIBLE–AIR CONDITIONER DISCONNECTS

U3803

AC DISCONNECT / SPA BOX

Combination AC Disconnect / 20 Amp GFCI Receptacle–Together in 1 Box

AC DISCONNECT / SPA BOX

DISCONNECTS

6

• Meets NEC # 210.63 Requirements *
• UL Listed as Power Outlet
• Type 3R Enclosure
• In-Use Cover**
• Duplex Ground Connector
• 1” Concentric Knockouts
*

60 amp,
Non-Fused
AC Disconnect

AC DISCONNECT
• 1∅, 240 Volt
• 60 amp, Non-Fused

Duplex 20 amp
GFCI Receptacle
Type 3R
Enclosure with
In-Use Cover

GFCI RECEPTACLE
• 20 amp
• Reset/Test Button
• Padlock provision

U3822-20GR

AMP
60

TYPE

CATALOG MAX WT.
NUMBER H.P. #

NONFUSIBLE U3822-20GR

10

LINE & LOAD CONNECTOR
WIRE RANGE

6

NEC® #210.63 Heating, AirConditioning and Refrigeration
Equipment Outlet.
...The receptacle shall be located on the same level and within
7.5 m (25 ft.) of the heating, airconditioning and refrigeration
equipment.
* NEC® #210.08 Ground-Fault
Circuit– Interruptor protection
for personnel.

GROUND CONNECTOR
WIRE RANGE

CU

AL

CU/AL

#14-#2
AWG

#12-#2
AWG

#14-4 AWG

DIMENSIONS

WIRE RATING

D″″

CU °C

W″″

H″″

AL °C

4.8 5.25 7.4 60°/75° 60°/75°

To ensure the safest conditions, Milbank disconnect pullers are designed to be reversible so they may be reinstalled in the OFF position.
All units are designed with a padlock provision on the cover for security.
**Note: U3822-20GR cover rated as IN-USE COVER (Cover may be closed with cords plugged into receptacle).
*Reprinted with permission from NFPA 70-2002, National Electrical Code®, Copyright 2001, National Fire Protection Association, Quincy, MA 02269. This reprinted material is not the complete
and official position of the NFPA on the referenced subject, which is represented only by the standard in its entirety. National Electrical Code® and NEC® are registered trademarks of the
National Fire Protection Association, Quincy, MA.

Hot Tub Disconnect or Sub Panel Breaker Enclosure–Type 3R
Spa Box with GFCI Protection
•
•
•
•
•
•
•
•
•
•
•

240 volt ground fault protection
UL listed, Type 3R rainproof
Milbank reliability
Easy installation
2 pole, 50 amp GFCI breaker protection
Compact size:
8-1/2” H x 7-1/2” W x 3-3/4” D
3 or 4 wire installation
1∅, 120 / 240 VAC
Standard package of 12
2 extra one-pole breaker spaces
100 amp overall rating

Sub Panel Breaker Enclosure
• Use as a 100 amp, 4 circuit sub panel
enclosure
• U4881-O has provision for (2) 2-pole or
(4) 1-pole small frame breakers

U4881-O-50GB

AMP TYPE

CATALOG
NUMBER

WT.
#

U4881-O

LINE & LOAD CONNECTOR
WIRE RANGE

GROUND CONNECTOR
WIRE RANGE

DIMENSIONS

CU

AL

CU/AL

D″″

W″″

H″″

7

#14-1/0

#14-1/0

#14-1/0

3 3⁄4

71⁄2

81⁄2

50 BREAKER U4881-O-50GB

8

#14-1/0

#14-1/0

#14-1/0

3 3⁄4

71⁄2

81⁄2

60 BREAKER U4881-O-60GB

8

#14-1/0

#14-1/0

#14-1/0

3 3⁄4

71⁄2

81⁄2

–

BREAKER
PROVISION

6

125 AMP–4 TERMINAL–RINGLESS–600 VAC

SINGLE POSITION

1

7

2
7487

5

125 AMP–4 TERMINAL–RINGLESS–600 VAC

3

4

4
6

U7487-RL-TG-KK

∅3W
125 AMP–4 TERMINAL*–RINGLESS–1∅
SERVICE AMP
OH

125

CATALOG
NUMBER

DIMENSIONS
HUB CONNECTORS BYCU/AL
PASS D″″ W″″ H″″

U7487-RL-TG-KK H.O.

#6-2/0

HORN

5

3

⁄16

8

111⁄2

CONCENTRIC K.O.’S
1

2

3

4

5

1

1

2

11⁄4

—

1

⁄2

1

⁄2

6
1

⁄4

HUBS: For proper hub selection see the hub suffix chart on the accessory page.
BYPASS: The -KK horn type bypass is factory installed and permits changing and testing of the meter without interrupting
customer service.
CONNECTORS: Extruded aluminum connectors are tin plated. Units are supplied with duplex neutral.
*FIFTH TERMINAL: For field mounted fifth terminal, order catalog number 5T24R.

Utility requirements for this equipment may vary. Always consult the serving utility for their requirements before ordering or
installing equipment in this catalog.

7

8

200 AMP–4 TERMINAL–RINGLESS–600 VAC

200 AMP–4 TERMINAL–RINGLESS–600 VAC

SINGLE POSITION

1
1

2

4

2

4

3
55

7040
8949

6

7021
5

3

6

U7040-RL-TG-KK

U7021-RL-TG-KK

1

3

2

1980
4

5

6

U1980-O-KK

200 AMP–4 TERMINAL–RINGLESS
CONNECTORS
CATALOG
NUMBER

SERVICE
OH

U8949-RL-TG-KK

OH

U7021-RL-TG-KK

OH/UG

U7040-RL-TG-KK

BY- DIMENSIONS
PASS D″″ W″″ H″″

CU/AL

HUB
LINE

LOAD

H.O. #6-350 kcmil #6-350 kcmil
H.O. #6-350 kcmil #6-350 kcmil
H.O. #6-350 kcmil #6-350 kcmil

HORN
HORN
HORN

1

⁄8

4

1

⁄8

4

1

⁄8

4

8
8
11

15

1

15

1

15

1

CONCENTRIC K.O.’S

⁄2
⁄2
⁄2

1

2

3

4

5

1

1

1

11⁄4

—

1

—

1

1

1

⁄2

2

1

⁄2

2

1

⁄2

2

⁄2

2

1

⁄2

2

1

⁄2

2

2
2
2

⁄2
⁄2
⁄2

⁄2

2

6

⁄4

1

⁄4

1 1
4, 2

⁄ ⁄

1 1
4, 2

1

⁄ ⁄

⁄4

HUBS: For proper hub selection see the hub suffix chart on the accessory page.
FIFTH TERMINAL: For field mounted fifth terminal for U8949, U7021 & U7040, order catalog number K5T.
CONNECTORS: Extruded aluminum connectors are tin plated.
GROUND: For indoor service for U8949 order as extra catalog number BL1048-KK block assembly to be installed to provide
insulated neutral.

200 AMP–4 TERMINAL–SIDE WIREWAY–RINGLESS
CONNECTORS
AMP SERVICE
200

UG

CATALOG
NUMBER
U1980-O-KK

LINE
BLANK

BY- DIMENSIONS
PASS D″″ W″″ H″″

CU/AL

HUB

LOAD

#6-350 kcmil #6-350 kcmil

HORN

1

4

⁄2

13

15

1

⁄4

CONCENTRIC K.O.’S
1

2

1

1

2

⁄2

2

⁄2

3

4

5

6

3

1

1

1 1
4, 2

1

⁄2

2

⁄2

⁄ ⁄

FIFTH TERMINAL: For factory installed fifth terminal in the 9 o’clock position add the suffix -5T. For field mounted fifth terminal
order catalog number K5T.
CONNECTORS: Extruded aluminum connectors are tin plated. Units are supplied with triplex neutral.

Utility requirements for this equipment may vary. Always consult the serving utility for their requirements before ordering or
installing equipment in this catalog.

8

200 AMP–5 & 7 TERMINAL–LEVER BYPASS–HEAVY DUTY–RINGLESS–600 VAC

9

6

1

3

SINGLE POSITION

5

2
9550
9700
6

2

3

9551
9701

U9701-O

4

U9550-RL

55

4
6

∅3W
200 AMP–5 TERMINAL–RINGLESS–3∅
CONNECTORS
AMP SERVICE

CATALOG
NUMBER

200

OH

U9550-RL*

200

UG

U9551-O*

CU/AL

HUB
LINE

LOAD

BY- DIMENSIONS
PASS D″″ W″″ H″″
7

10

7

13

H.O. #6-350 kcmil #6-350 kcmil

LEVER

4

BLANK

LEVER

4

#6-350 kcmil #6-350 kcmil

⁄8
⁄8

CONCENTRIC K.O.’S
1

2

1

3

1

2

19

3

2

1

18

⁄2

⁄2
⁄2

3

4

5

3

—

1 1
4, 2

3

3

6
3

⁄ ⁄
1

⁄4

⁄4

1 1
4, 2

⁄ ⁄

*Grounded B phase (may be field isolated).
HUBS: For proper hub selection see the hub suffix chart on the accessory page.
BYPASS: Lever supplies clamping action on meter spades and also operates bypass device.
CONNECTORS: Units supplied with extruded aluminum connectors and bonded triplex ground.
FIFTH TERMINAL: Fifth terminal is supplied in the 6 o’clock position. For factory installed fifth terminal in the 9 o’clock position add the suffix -5T9 to the catalog number.

∅4W
200 AMP–7 TERMINAL–RINGLESS–3∅
CONNECTORS
AMP SERVICE

CATALOG
NUMBER

200

OH

U9700-RRL

200

UG

U9701-O

CU/AL

HUB
LINE

LOAD

BY- DIMENSIONS
PASS D″″ W″″ H″″
7

10

7

13

H.O. #6-350 kcmil #6-350 kcmil

LEVER

4

#6-350 kcmil #6-350 kcmil

LEVER

4

BLANK

⁄8
⁄8

CONCENTRIC K.O.’S
1

2

1

3

1

2

19

3

2

1

18

⁄2

⁄2
⁄2

3

4

5

3

—

1 1
4, 2

3

3

⁄ ⁄
1

⁄4

6
3

⁄4

1 1
4, 2

⁄ ⁄

HUBS: For proper hub selection see the hub suffix chart on the accessory page.
BYPASS: Lever supplies clamping action on meter spades and also operates bypass device.
CONNECTORS: Units supplied with extruded aluminum connectors and bonded triplex ground.
INSULATED NEUTRAL: For field installed insulated neutral for the U9701 order kit number K1047.

Utility requirements for this equipment may vary. Always consult the serving utility for their requirements before ordering or
installing equipment in this catalog.

9

200 AMP–5 & 7 TERMINAL–LEVER BYPASS–HEAVY DUTY–RINGLESS–600 VAC

1

10

320 AMP–4 TERMINAL–LEVER BYPASS–HEAVY DUTY–RINGLESS–600 VAC

320 AMP–4 TERMINAL–LEVER BYPASS–HEAVY DUTY–RINGLESS–600 VAC

SINGLE POSITION

3” KO–right
side only
3000

2

1
4

3
5

1779

4
6

U1779-RRL
(shown with optional
hub installed)

U3000-O-K3L-K2L

∅3W–600 VAC
320 AMP–4 TERMINAL–RINGLESS–1∅
CONNECTORS
SERVICE

UG
OH

CATALOG
NUMBER
U3000-O-K3L-K2L
U1779-RRL

CU/AL

HUB
LINE

BLANK #4-600 kcmil

(2) 1/0-250 kcmil
3/8″-16
H.O.
STUD

LOAD
TWIN #6-350
kcmil
3/8″-16
STUD

5T
KIT
K3865
K3866

BY- DIMENSIONS
PASS D″″ W″″ H″″
LEVER
LEVER

7

4

⁄8

7

4

⁄8

15

30

13

3

38

⁄4

CONCENTRIC K.O.’S
1

2

3

4

5

3

3

3

3

1

1 1
4, 2

3

1

3

1

1 1
4, 2

2

⁄2

3

⁄4
⁄4

6

⁄ ⁄
⁄ ⁄

HUBS: For proper hub selection see the hub suffix chart on the accessory page.
BYPASS: Lever supplies clamping action and also operates bypass device.
CONNECTORS: Stud type units supplied with 3/8″-16 hex head nuts with Belleville washers. For connector kits, order as extra
K1540 (600 kcmil). For twin lug connectors order as extra K1350 (350 kcmil). U3000-O-K3L-K2L uses K1540L (single 600)
or K1350L (twin 350) non-rotating connectors for load side. Separate kits are required for both line and load.
FIFTH TERMINAL: For factory installed fifth terminal in the 6 o’clock position add the suffix -5T6 to the catalog number. For
factory installed fifth terminal in the 9 o’clock position at the suffix -5T9 to the catalog number. For field installed fifth terminal, order as extra K3865.

Utility requirements for this equipment may vary. Always consult the serving utility for their requirements before ordering or
installing equipment in this catalog.

10

320 AMP CONTINUOUS–7 TERMINAL–LEVER BYPASS–HEAVY DUTY–RINGLESS–600 VAC

11

320 AMP CONTINUOUS
400 AMP MAX.

SINGLE POSITION

2
3

5

6

4

U2594-X-K7-INV
(Shown without lugs)

∅4W
320 AMP–SIDE WIREWAY–7 TERMINAL–RINGLESS–3∅
CONNECTORS
AMP SERVICE
320

OH/UG

CATALOG
NUMBER

CU/AL

HUB

U2594-X-K7-INV C.P.

LINE

LOAD

#4-600
kcmil

3/8″-16
STUD

BY- DIMENSIONS
PASS D″″ W″″ H″″
LEVER

1

6

⁄2

19

34

1

⁄8

CONCENTRIC K.O.’S
1
–

2
3

3
4

4

5

4

1

⁄4

6
1

⁄2,3⁄4,1

HUBS: For proper hub selection see the hub suffix chart on the accessory page.
BYPASS: Lever supplies clamping action on meter spades and also operates bypass device.
CONNECTORS: Type K7 single barrel 600 kcmil (catalog number K3441) line side lugs included. For load side lugs, stud type
units are supplied with 3/8″-16 hex head nuts with Belleville washers. For single lug connector kits, order as extra K3441 (600
kcmil). For twin lug connectors order as extra K3442 (350 kcmil).
.

Utility requirements for this equipment may vary. Always consult the serving utility for their requirements before ordering or
installing equipment in this catalog.

11

320 AMP CONTINUOUS–7 TERMINAL–LEVER BYPASS–HEAVY DUTY–RINGLESS–600 VAC

2594

12

100 & 200 AMP / POSITION–4 TERMINAL–HORIZONTAL GANG–RINGLESS–300 VAC

4″″ SIDE WIREWAY
OH/UG SERVICE

L572-XL-KK

100 & 200 AMP / POSITION–4 TERMINAL–HORIZONTAL GANG–RINGLESS
300 VAC

MULTIPLE POSITION

1

4

5

U1252-X-KK (Shown with optional line side connectors)

2

1

3

3

1

1

1

2

1

2

1

1252

L572-6

4

5

3

5

6

5

1253-6

4

4

3

5

7

4

6

5

4

5

7

∅3W–OVERHEAD–300 VAC
100 AMP / POSITION– 4 TERMINAL–RINGLESS–1∅
AMPS

NO.
OF
POS.

CATALOG
NUMBER

HUB

100

2

L572-XL-KK

C.P.

100

3

L573-XL-KK

C.P.

100

4

L574-XL-KK

C.P.

100

5

L575-XL-KK

C.P.

100

6

L576-XL-KK

C.P.

CONNECTOR
CU/AL

LINE
#2-350
kcmil
#2-350
kcmil
#2-350
kcmil
#2-350
kcmil
#2-350
kcmil

BY- DIMENSIONS
PASS
LOAD
D″″ W″″ H″″

CONCENTRIC K.O.’S
1

2

3

4

5

#6-2/0

HORN

41⁄2 205⁄16 16

2

2

2

21⁄2

1

⁄4,1⁄2

#6-2/0

HORN

41⁄2 281⁄2

16

2

2

2

21⁄2

1

#6-2/0

HORN

41⁄2 4011⁄16 16

2

2

2

21⁄2

1

#6-2/0

HORN

41⁄2 487⁄8

16

2

2

2

21⁄2

1

#6-2/0

HORN

41⁄2 571⁄16 16

2

2

2

21⁄2

1

⁄4,1⁄2
⁄4,1⁄2
⁄4,1⁄2
⁄4,1⁄2

CONNECTORS: Extruded aluminum connectors are tin plated.
BUSSING: Supplied with 5/16″ x 1″ aluminum bussing.
FIFTH TERMINAL: For field installed fifth terminal, order as extra catalog number 5T8K2 for the 6 o’clock position, and Kit #K9959 for the
9 o’clock position.
EXTRA WIRE SPACE: Extra wire space of 4″ provided on the left end of 2 and 3 position gangs. Furnished on both ends of 4, 5, and 6 position
gangs.
MAIN BUS RATING: For main bus rating, see the conduit and ampacity information page in this catalog.
BYPASS: The -KK horn type bypass is factory installed and permits changing and testing of the meter without interrupting customer service when
used with utility-supplied jumpers.

∅3W–OH/UG–300 VAC
150 & 200 AMP / POSITION–4 TERMINAL–RINGLESS–1∅
NO.
OF
POS.

CATALOG
NUMBER

HUB

2

U1252-X-KK*

C.P.

3

U1253-X-KK*

C.P.

4

U1254-X-KK*

C.P.

5

U1255-X-KK*

C.P.

6

U1256-X-KK*

C.P.

CONNECTOR
CU/AL

LINE

BY- DIMENSIONS
LOAD PASS D″″ W″″ H″″

3/8″-16
STUD
3/8″-16
STUD
3/8″-16
STUD
3/8″-16
STUD
3/8″-16
STUD

#6-350
kcmil
#6-350
kcmil
#6-350
kcmil
#6-350
kcmil
#6-350
kcmil

HORN

CONCENTRIC K.O.’S
1

2

3

4

14

21⁄2

21⁄2

3

⁄8 34 ⁄16 14

21⁄2

21⁄2

16

21⁄2

⁄8 54 ⁄8 16

51⁄8 261⁄2
1

11

HORN

5

HORN

51⁄8 427⁄8
1

7

HORN

5

HORN

51⁄8 637⁄8

18

5

6

7

21⁄2

1

1

1

3

21⁄2

1

1

1

21⁄2

3

21⁄2

1

1

1

21⁄2

21⁄2

3

21⁄2

1

1

1

21⁄2

21⁄2

3

21⁄2

1

1

1

⁄2
⁄2
⁄2
⁄2
⁄2

⁄4
⁄4
⁄4
⁄4
⁄4

HUB: For proper hub selection refer to the hub suffix chart on the accessory page. For the U1255 & U1256 units, two hub openings are supplied
and the extra opening is closed with a closing plate as standard.
FIFTH TERMINAL: For field mounted fifth terminal order catalog number K5T for 9 o’clock position.
*CONNECTORS: Extruded aluminum connectors are tin plated. Units supplied with 3/8″–16 hex head nuts with Belleville washers on line side.
Order connector kit K1541 (600 kcmil) as extra.
BUSSING: Refer to the Conduit & Ampacity Section on page 25 of this catalog for information on ampacity of bussing.
FOR OVERHEAD SERVICE: The U1254, U1255, and the U1256 units are factory assembled for underground service. If overhead service is
desired an extension kit is required; order catalog number K3923 for the U1254 and U1255 units, and K3955 for the U1256 unit. For factory
installed overhead service add suffix -EX to the catalog number.

Utility requirements for this equipment may vary. Always consult the serving utility for their requirements before ordering or
installing equipment in this catalog.

12

200 AMP / POSITION–7 TERMINAL–HORIZONTAL GANGS
LEVER BYPASS–HEAVY DUTY–RINGLESS–600 VAC

1

1

1

3

4

5

13

2

4

CENTER WIREWAY

MULTIPLE POSITION

U2732-XT-PED
(shown without pedestal)

AMPS SERV.

NO.
OF
POS.

CATALOG
NUMBER

HUB

200

OH/UG

2

U2732-XT-PED (2)C.P.

200

OH/UG

3

U2733-XT-PED (2)C.P.

200

OH/UG

4

U2734-XT-PED (2)C.P.

CONNECTOR
CU/AL

LINE

LOAD

3/8″-16
STUD
3/8″-16
STUD
3/8″-16
STUD

#6-350
kcmil
#6-350
kcmil
#6-350
kcmil

BYPASS

DIMENSIONS
D″″

W″″

CONCENTRIC K.O.’S

H″″

1

2

3

4

5

PED

21⁄2

1 1
4, 2

6

321⁄8 251⁄4

21⁄2

21⁄2

LEVER

6

423

21

21

⁄2

PED

21

⁄2

1 1
4, 2

LEVER

6

521⁄4 251⁄4

21⁄2

21⁄2

PED

21⁄2

1 1
4, 2

LEVER

⁄16

251

⁄4

⁄2

⁄ ⁄
⁄ ⁄
⁄ ⁄

HUBS: Units supplied with two closing plates. To order hubs as extra refer to the hub suffix chart on the accessory page.
BYPASS: Lever supplies clamping action on meter spades and also operates bypass device.
*CONNECTOR KITS: Line wire sections supplied with studs. For connector kits order K3082 (single-350 kcmil), K3441 (single600 kcmil), or twin K3442 (twin-350 kcmil) or K3083 (twin-600 kcmil.) Line connectors can be reversed to change from OH to
UG service.
*UNDERGROUND PEDESTALS: For underground service order S2291-TO pedestal raceway. A 12″ pedestal extension kit is
also available. Order catalog number S2571.
BUSSING: Bussing is 3/8″ x 1″ aluminum. Refer to the conduit & ampacity page of this catalog for information on ampacity of
bussing.

Utility requirements for this equipment may vary. Always consult the serving utility for their requirements before ordering or
installing equipment in this catalog.

13

200 AMP / POSITION–7 TERMINAL–HORIZONTAL GANGS
LEVER BYPASS–HEAVY DUTY–RINGLESS–600 VAC

∅4W–OVERHEAD / UNDERGROUND*
200 AMP –7 TERMINAL–RINGLESS–3∅

14

CONDOMINIUM METERING BANKS–RINGLESS–OH/UG SERVICE–1∅3W–120 / 240 VAC

U2864-X-PED-KK
(Order breakers and pedestal
raceway as extra)

U2866-X
(Shown without pedestal)

∅
VERTICAL—1∅

200 AMP/POSITION

CONDOMINIUM METERING BANKS–RINGLESS–
OH/UG SERVICE–1∅3W–120 / 240 VAC

CONDO MTR. BANKS

125 AMP/POSITION
NO.
OF
POS.

CATALOG
NUMBER

2

U2852-X-KK-K1-PED

200 amp

3

U2853-X-KK-K1-PED

200 amp

NO.
OF
POS.

CATALOG
NUMBER

#6-350 kcmil

2

U2862-X-KK-K1-PED

250 amp

#6-350 kcmil

#6-350 kcmil

3

U2863-X-KK-K1-PED

300 amp

#6-350 kcmil

LINE
MAIN BUS
CONNECTOR
RATING
SIZE

∅
RECTANGULAR—1∅

125 AMP/POSITION
NO.
OF
POS.

CATALOG
NUMBER

4

U2854-X-KK-PED

400 amp

5

U2855-X-KK-PED

6

U2856-X-KK-PED

SUFFIX

200 AMP/POSITION

NO.
OF
POS.

CATALOG
NUMBER

*3/8″-16 STUD

4

U2864-X-KK-PED

400 amp

*3/8″-16 STUD

400 amp

*3/8″-16 STUD

5

U2865-X-KK-PED

600 amp

*3/8″-16 STUD

400 amp

*3/8″-16 STUD

6

U2866-X-KK-PED

600 amp

*3/8″-16 STUD

LINE
MAIN BUS
CONNECTOR
RATING
SIZE

KIT
COMPATIBLE
NUMBER
WITH

-K1

K1539

-K3

K1540

-K2

K1350

-K4

K1541

SINGLE

TWIN

U2852-56
U2862-66
U2854-56
U2864-66
U2854-56
U2863-66
U2864-66

LINE
MAIN BUS
CONNECTOR
RATING
SIZE

*CONNECTORS: For line wire connector kits, order
separately.
FIFTH TERMINALS: For field mounted fifth terminal
order catalog number K2381. Order one per meter
position (9 o’clock position only).
BREAKERS: Units have provision for one double pole
main per meter position. Breakers not included, order
as extra Milbank type Q or QNR or comparable.
Refer to the accessories section in back of catalog.
UNDERGROUND SERVICE: For underground service
order S2291-TO pedestal raceway. Order separately.
PEDESTAL EXTENSION KIT: A 12” pedestal extension kit is also available. Order catalog number
S2571.

CONNECTOR KITS *
SIZE

LINE
MAIN BUS
CONNECTOR
RATING
SIZE

WIRE
RANGE
#6-350
kcmil
#4-600
kcmil
#6-350
kcmil
#2-600
kcmil

Utility requirements for this equipment may vary. Always consult the serving utility for their requirements before ordering or
installing equipment in this catalog.

14

CONDOMINIUM METERING BANKS–RINGLESS–OH/UG SERVICE–1∅3W–120 / 240 VAC

15

CONDOMINIUM METERING BANKS
VERTICAL
with pedestal option in bottom
125 amp/pos.
(2-3 position)

200 amp/pos.
(2-3 position)

D

D

25" or
37"

29" or
41"

U2852-X

FIG.

DIMENSIONS

A

11⁄4 ″ CONCENTRIC K.O.

B

1

⁄4,1⁄2″ CONCENTRIC K.O.
3″ CONCENTRIC K.O.

D

4″ HUB OPENING

E

2″ CONCENTRIC K.O.

18"
E

E

E

PED

4-7/8"

CONDO MTR. BANKS

C

4-7/8"

PED

A A A

21"

RECTANGULAR
PEDESTAL OPTION

PEDESTAL OPTION

Pedestal Raceway
S2291-TO

Pedestal Extension Unit
S2571

with pedestal option in bottom
125 amp/pos.
(4,5 & 6 position)

200 amp/pos.
(4,5 & 6 position)

PED

C

25" or
37"
29" or
41"

A

A

A

PED
31"

A

A

A

4-7/8"
E

E

E

PED

E

E

E

4-7/8"

36"

FIFTH TERMINAL # K2381
(125-200 amp)

Utility requirements for this equipment may vary. Always consult the serving utility for their requirements before ordering or
installing equipment in this catalog.

15

CONDOMINIUM METERING BANKS–RINGLESS–
OH/UG SERVICE–1∅3W–120 / 240 VAC

C

16

100 / 200 AMP–4 TERMINAL–RESIDENTIAL PEDESTAL
SINGLE OR DOUBLE POSITION–1∅3W–600 VAC

3
5

100 / 200 AMP–4 TERMINAL–RESIDENTIAL PEDESTAL
SINGLE OR DOUBLE POSITION–1∅3W–600 VAC

1
3

2

2

2
GRADE LINE

4

18.00

U8436-O

PEDESTALS

Extension Unit
K5800

∅3W—600 VAC
100 / 200 AMP—4 TERMINAL—CECHA APPROVED—RINGLESS—1∅
CONNECTORS
AMP SERVICE
200

UG

CATALOG
NUMBER
U8436-O

BLANK

BY- DIMENSIONS
PASS D″″ W″″ H″″

CU/AL

HUB
LINE

LOAD

4/0
Crimp-On

#6-350
kcmil

HORN

1

4

⁄8

9

62

CONCENTRIC K.O.’S
1
2

2
2

3
5

⁄16

4

5

6

1

2

—

⁄2

HANGING HOOK: Supplied with keyhole hanger for easy mounting.
EXTENSION UNIT: For 15” burial applications, order extension unit K5800; for 30” applications, order (2) K5800 units.
FIFTH TERMINAL: For field installed fifth terminal, order catalog number K5T (9 o’clock position).
BYPASS: Horn type bypass.

Utility requirements for this equipment may vary. Always consult the serving utility for their requirements before ordering or
installing equipment in this catalog.

16

100 / 200 AMP–5 & 7 TERMINAL–LEVER BYPASS–HEAVY DUTY PEDESTAL–600 VAC

4

4

17

PEDESTAL EXTENSION UNIT
S3488

MILBANK

100 / 200 AMP–5 & 7 TERMINAL–LEVER BYPASS
HEAVY DUTY PEDESTAL–600 VAC

1

3

2

4

4

4

4

9108
9107

U9107-O

∅-3W OR 3∅
∅-3W
100 / 200 AMP—5 TERMINAL—HEAVY DUTY—1∅
#
OF
TERMS
5

CATALOG
NUMBER
U9108-O

SERVICE
UG

HUB
BLANK

CONNECTORS
CU/AL
LINE
LOAD

BYPASS

#6-350
kcmil

LEVER

3/0-4/0

DIMENSIONS

CONCENTRIC K.O.’S

D″″

W″″

H″″

1

2

3

6

11

58

21⁄2

21⁄2

21⁄2

4

5

⁄16

—

5

#
OF
TERMS
7

CATALOG
NUMBER
U9107-O

SERVICE
UG

HUB
BLANK

CONNECTORS
CU/AL
LINE
LOAD

BYPASS

#6-350
kcmil

LEVER

3/0-4/0

DIMENSIONS

CONCENTRIC K.O.’S

D″″

W″″

H″″

1

2

3

6

11

58

21⁄2

21⁄2

21⁄2

4

5

⁄16

—

5

BYPASS: Lever supplies clamping action on meter spades and also operates bypass device.
BOTTOM PLATE: Bottom plate is not furnished with this unit. However, if plate is required, order catalog number S9157 as
extra.
NEUTRAL: The U9108-O is supplied with a center disconnect neutral.
EXTENSION KIT: For direct burial applications, order kit S3488 as separate item.

Utility requirements for this equipment may vary. Always consult the serving utility for their requirements before ordering or
installing equipment in this catalog.

17

PEDESTALS

∅4W
100 / 200 AMP—7 TERMINAL—HEAVY DUTY—3∅

18

100 OR 200 AMP–CIRCUIT BREAKER MAIN DISCONNECT–SINGLE POSITION
METER MAIN–240 VAC

M I L B A N K

2

1

100 OR 200 AMP–CIRCUIT BREAKER MAIN DISCONNECT
SINGLE POSITION–METER MAIN–240 VAC

3

4

U7375-RL-KK

U7607-RL-200-KK
(Supplied with 200 Amp circuit breaker)

∅
100 AMP–4 TERMINAL—METER MAIN (PLUG-IN)—RINGLESS—1∅
CATALOG
NUMBER
U7375-RL-KK

SERVICE
OH

HUB
H.O.

CONNECTORS
CU/AL
LINE
LOAD
#6-2/0

BYPASS

DIMENSIONS
D″″

W″″

⁄4

3

C.B.

HORN 3

⁄8

1

8

CONCENTRIC K.O.’S

H″″

1

22

1

1

2

⁄4

3

⁄4

1

1

⁄4

1

1

4

5

⁄ ⁄

—

1 1
4, 2

CIRCUIT BREAKER: Main circuit breaker not supplied with unit. For 100 amp service order Milbank catalog number
Q2100 separately. See circuit breaker chart on accessory page for other compatible models.

METER MAINS

∅
200 AMP–4 TERMINAL—METER MAIN—RINGLESS—1∅
CATALOG
NUMBER
U7607-RL-200-KK

SERVICE
OH

HUB
H.O.

CONNECTORS
CU/AL
LINE
LOAD
#6-350
#1-300
kcmil
kcmil

BYPASS

DIMENSIONS
D″″

⁄2

1

HORN 4

W″″

⁄8

1

8

H″″
29

CONCENTRIC K.O.’S
1
2

2
2

3

4

5

2

1 1
4, 2

⁄ ⁄

—

CIRCUIT BREAKER: 200 amp main circuit breaker factory bussed. Order Milbank catalog number UQFB-200-X1 for
replacement. Other amperages available. See Milbank circuit breaker chart on accessory page.
HUBS: Order hubs separately–see accessory page for ordering information.
FIFTH TERMINAL: For field mounted fifth terminal for U7375 order catalog number 5T8K2. For field mounted fifth
terminal for U7607 order catalog number K5T. Mount in the 9 o’clock position only.

Utility requirements for this equipment may vary. Always consult the serving utility for their requirements before ordering or
installing equipment in this catalog.

18

100 / 200 AMP–4 TERMINAL–METER PEDESTAL–PARALLEL MAIN–1∅–120 / 240 VAC

STD = 79"
-LP = 70"

1
2

Grade Line

STD = 36"
-LP = 24"

NU8980-O-KK

∅3W–UG–10K / 22K AIC RATING
100 / 200 AMP–4 TERMINAL–C/B–RINGLESS–1∅
CATALOG NUMBER
W/ BREAKER
INSTALLED

HUB

NU8980-O-100-KK

BLANK

NU8980-O-100-KK-LP

BLANK

NU8980-O-200-KK

BLANK

NU8980-O-200-KK-LP

BLANK

CONNECTOR
CU/AL

MAIN BREAKER

DIMENSIONS

CONCENTRIC K.O.’S

BYPASS

10K

22K

D″″

W″″

H″″

1

2

3

LINE

LOAD

#6-350
KCMIL
#6-350
KCMIL
#6-350
KCMIL
#6-350
KCMIL

C/B

HORN

UQFP

UQFPH

6

9

79

21⁄2

21⁄2

—

C/B

HORN

UQFP

UQFPH

6

9

70

21⁄2

21⁄2

—

C/B

HORN

UQFP

UQFPH

6

9

79

21⁄2

21⁄2

—

C/B

HORN

UQFP

UQFPH

6

9

70

21⁄2

21⁄2

—

Utility requirements for this equipment may vary. Always consult the serving utility for their requirements before ordering or
installing equipment in this catalog.

19

METER MAINS

MAIN CIRCUIT BREAKERS: For 10K AIC order with factory installed main. For 22K AIC order pedestal without main and order
circuit breaker separately. All main breakers are parallel connected. For series wired main order wire kit K4714 and UQFP-M
type circuit breaker. See Milbank circuit breaker chart on accessory page.
BRANCH CIRCUIT BREAKERS: Branch Interior accepts most manufacturers <100 amp. See plug-in breaker compatibility chart
on accessory page.
FIFTH TERMINAL: For field installed 5th terminal order 5T8K2. Mounts in 9 o'clock position only.
BYPASS: All pedestals have horn-type bypass installed for meter testing or replacement without interrupting customer service.
EXTENSION KIT: Available for low profile (-LP) units only. Order kit K4694. See accessory page.

100 / 200 AMP–4 TERMINAL–METER PEDESTAL–PARALLEL MAIN–1∅–120 / 240 VAC

MILBANK

19

20

320 AMP–4 TERMINAL–METER MAIN–LEVER BYPASS–HEAVY DUTY–2/200 AMP CB

3

320 AMP CONTINUOUS
400 AMP MAX

3

320 AMP–4 TERMINAL–METER MAIN–LEVER BYPASS–HEAVY DUTY–2/200 AMP CB

4

4

1

1

2

2

M I L B A N K

1

3

2
Grade Line

Grade Line

Grade Line

Grade Line

4 18"

4
18"
3

3

4-27/32"
I.D.

13"
O.D.

16-15/16"
15"

U3849-O-2/200-INV

S1848
Pedestal Extension Unit

U1748-O-WI

∅3W
320 AMP–4 TERMINAL–METER MAIN WITH BREAKERS–RINGLESS–240 VAC–1∅
CATALOG
NUMBER

SERVICE

HUB

U3849-O-2/200-INV

UG

BLANK

CONNECTORS
CU/AL
LINE
LOAD
3/8″ X 16
STUDS

DIMENSIONS

BYPASS

C.B. #1- 300 LEVER
kcmil

CONCENTRIC K.O.’S

D″″

W″″

H″″

1

2

47⁄8

13

64

21⁄2

21⁄2

3

4

5

⁄16

—

—

5

BREAKERS: Supplied from factory with 2 double-pole, 200 amp Milbank UQFB-200 or UQFBH-200 (22,000 AIC) bolt-on circuit breakers.
* Must order 22K AIC breakers separately. Order Milbank UQFBH-200 breakers.
CONNECTORS: The line wire section is supplied with 3/8”-16 studs with hex nuts and captive Bellville washers. For line side connectors, order as
extra catalog numbers K1539 (single-350 kcmil), or K1540 (single-600 kcmil), or for twin K1350 (twin-350 kcmil). Order one kit per unit.
EXTENSION KIT: For extension kit order as extra catalog number S1848.
.

METER MAINS

∅3W
320 AMP–4 TERMINAL–WITHOUT BREAKER PROVISION–RINGLESS–600 VAC–1∅
CATALOG
NUMBER
U1748-O-WI

SERVICE
UG

HUB
BLANK

CONNECTORS
CU/AL
LINE
LOAD
3/8″ X 16
STUDS

TWIN #6350 kcmil

BYPASS
LEVER

DIMENSIONS
D″″

⁄8

7

4

W″″
13

CONCENTRIC K.O.’S

H″″

1

64

1

2

⁄2

2

⁄2

1

2

3

⁄2

1

2

4

5

⁄16

—

5

CONNECTORS: The line wire section is supplied with 3⁄8″–16 studs with hex head nuts and captive Belleville washers. The line
side connectors are to be supplied by the Utility, load side is furnished.
BYPASS: The lever supplies clamping action on the meter spade and also operates the bypass device.
FIFTH TERMINAL: For field installed fifth terminal order kit number K3865.
PEDESTAL EXTENSION KIT: If extension kit is required, order as extra kit number S1848. See accessory page.
.

Utility requirements for this equipment may vary. Always consult the serving utility for their requirements before ordering or
installing equipment in this catalog.

20

200 AMP–SERIES U5136 & U5137–RINGLESS–METERED PEDESTAL

U5136-O-200S

SINGLE PEDESTAL
CATALOG #
U5136-O-100S
U5136-O-200S
U5136-O-200S/22

MAIN BREAKER
UQFP-M-100
UQFP-M-200
UQFPH-M-200

AMPS
100
200
200

INTERIOR
4 Circuit
4 Circuit
4 Circuit

WEIGHT (lbs)
82
82
82

DOUBLE PEDESTAL
CATALOG #
U5137-O-100S
U5137-O-200S
U5137-O-200S/22

MAIN BREAKER
(2) UQFP-M-100 Series
(2) UQFP-M-200 Series
(2) UQFPH-M-200 Series

AMPS
100
200
200

INTERIOR
4 Circuit
4 Circuit
4 Circuit

WEIGHT (lbs)
115
115
115

RECEPTACLE / CIRCUIT BREAKER KITS AND ACCESSORIES (Sold separately)
CATALOG #
RECEPTACLE
CIRCUIT BREAKER
CONDUCTOR
K5400-520
5-20R Duplex
20 amp, 1 Pole
12 Awg
K5400-520GR

5-20R Duplex GFI

20 amp, 1 Pole

12 Awg

K5400-TT30

TT30R

30 amp, 1 Pole

10 Awg

K5400-1450

14-50R

50 amp, 2 Pole

8 Awg

K5400-BRIDGE-1POS
K5400-BRIDGE-2POS
K5415
K5035
K5T
K5193

CONFIGURATION

GFI Rec.

Self-grounded one position receptacle bridge with hardware
Self-grounded two position receptacle bridge with hardware
Stabilizer foot with hardware
Pad mount kit with hardware (see note below)
5th terminal for 3 or 9 o’clock position
Wire kit to convert series wired main breaker to parallel

• A maximum of two receptacle / circuit breaker kits can be installed in each power head. Order from above. Other kits available.
Consult factory for factory-installed receptacle kits.
• Receptacle / circuit breaker kits include receptacle, circuit breaker, wire, cover plate and mounting screws.
• Receptacle bridge K5400-BRIDGE-1POS or K5400-BRIDGE-2POS not included with pedestal. Order separately.
• Pedestals are stocked with series wired main circuit breakers. Order K5193 kit to field convert to parallel main lug circuit
breaker. For parallel wired main circuit breakers, change “S” suffix to “P” (Ex.: U5136-O-100P).
• K5415 Stabilizer Foot sold separately. Recommended for double pedestals.
• Pad mount pedestals available. Order U5138 (single meter) or U5139 (double meter) prefix. K5035 pad mount kit required.
Order separately.

21

200 AMP–SERIES U5136 & U5137–RINGLESS–METERED PEDESTAL

24”

RV/MH

• UL Listed File E90945.
• 200 amp maximum, 120/240 V, 1∅3W.
• Ringless type meter socket with horn bypass and
stainless steel latch.
• Short circuit withstand rating 10K AIC, for 22K AIC, order
with “22” suffix.
• Type 3R construction for durable outdoor use.
• Milbank grey polyester powder coat finish.
• Wire terminations accept copper or aluminum conductors.
• Line & Neutral: (2) #6-350 kcmil per phase.
• Line Ground: (4) #14-1/0.
• Load (CB): 1/0 to 300 kcmil per pole.
• Load Neutral: (1) #6-350 kcmil.
• Load Ground: (2) #14-1/0, (4) #14/6.
• Commercial grade, plug-in main circuit breaker. Available
in 100, 125, 150 & 200 amp. Type UQFP-M.
• 4 circuit plated copper interior accepts (2) 2-pole or (4)
1-pole standard plug-in type circuit breakers. Branch
circuit rated to 125 amps max. Acceptable manufacturers:
Milbank, Cutler-Hammer, GE or Siemens.
• Factory or field installable receptacle bridge and receptacle / circuit breaker kits available. See accessories.

21

22

MILBANK ACCESSORIES

INTERCHANGEABLE UNIT HUBS

MISC.

HUB
ADAPTER PLATE
(Converts 4″ opening to
21⁄2″ opening)

S8324

SMALL “RL"OPENING
(STANDARD)
SUFFIX SIZE
1″

WL
YL
ZL
DL
EL

11⁄4″
11⁄2″

2″
21⁄2″

MILBANK
NO.

SUFFIX SIZE

A7514
A7515
A7516
A7517
A7518

3″

F
G
H

31⁄2″
4″

MILBANK
NO.

A8110
A8111
A8112

DESCRIPTION SUFFIX

CAT. #

STANDARD
(for -RL opening)

-XL

A7551

LARGE
(for -R opening)

-X

A9064

HUB SUFFIX CHART

CLOSING COVERS
MILBANK ACCESSORIES

REMOVABLE HUB
CLOSING PLATE

LARGE “R” OPENING
(HEAVY DUTY)

O
RL
R
XL
X

Plain Top
Small Hub Opening
Large Hub Opening
Small Closing Plate
Large Closing Plate
Large Hub Opening
RXL
adapted to small Closing Plate
METAL CLOSING PLATE

METER CLOSING PLATE

(for ringless sockets)

(Grey Plastic)

CP-21

6003

Large Hub Opening
RRL
adapted to small Hub Opening

WL 1″ For -RL Opening
YL 11⁄4″ For -RL Opening
ZL 11⁄2″ For -RL Opening
DL 2″ For -RL Opening
EL 21⁄2″ For -RL Opening
3″ For -R Opening
F
G

31⁄2″

For -R Opening

H

4″

For -R Opening

PEDESTAL EXTENSION UNITS
CATALOG
NUMBER

D″″

W″″

H″″

3

4 1⁄8
4 7⁄8
6

8 ⁄16
11
10
13
9

15
15
12
15
24

4 1⁄8

9

15

1

S8988
S3488
S2571
S1848
K4694
K5800

4 ⁄2
6

#K3235
STAKE KIT
Suitable for
use with
pedestals for
extra support

FOR CONDO METERING BANKS
(125-200 AMP) K2381

FIFTH TERMINALS

PLUG-IN FIFTH TERMINAL
5T8K2
(Fits in round hole of old
style block)

HEAVY DUTY JAW
CLAMPING
K3865

BOLT-IN FIFTH TERMINAL
5T24R
(Fits in round hole of old
style block)

22

FIFTH TERMINAL
K5T
(Fits in square hole
of new style 200 amp block)

MILBANK ACCESSORIES

CONNECTOR KITS

23

DISCONNECT SLEEVE
M5-144

For use with 3/8”-16
stud type units only
TWIN
SINGLE

SUFFIX

CATALOG #

(3 per set) – 1 ∅

K1539

K3
K3L

CATALOG #

(4 per set) – 3 ∅

K5

K3082

K7

K3441

6-350 kcmil
4-600 kcmil or
(2) 1/0-250 kcmil

K1350

K2L

K1350L

K4

K1541

6-350 kcmil
6-350 kcmil
Non-rotating
4-600 kcmil
(4 per set) – 3 ∅

SUFFIX CATALOG #

K6
K8

ISOLATED
NEUTRAL
KIT
K1047

6-350 kcmil
4-600 kcmil

K3442
K3083

MILBANK ACCESSORIES

SUFFIX

K2

LOAD TAP CONNECTORS (3 per set)
Replaces the load side slide-in nut assembly on
Milbank 200 amp sockets. Allows for a 100 amp tap
location in addition to the #6-350 kcmil load-side
connector. K5022 Includes Safety Barrier
Extensions–for applications over 300 VAC.
K4977-INT INTERNAL HEX
K5022-INT INTERNAL HEX

ANTI-INVERSION CLIP
SEALING RINGS
K4802

PLUG-IN BREAKER COMPATIBILITY CHART
AMPS MILBANK
125-200 Q / QNR
≤ 100

CUTLER-HAMMER SIEMENS
(WESTINGHOUSE) (ITE)

SIEMENS
MURRAY /
CROUSE-HINDS

G.E.

SQ-D

HQP / BR / WBJ Q / QN

MD

Q LINE

—

MP

Q LINE HOMELINE

QUICKLAG P /
BR / HQP

Q

QP

SCREW TYPE
MR-4

BUCKLE HASP
MR-8

MILBANK
2-POLE—200 AMP LARGE FRAME—10,000 AIC & 22,000 AIC
AMPS 10,000 AIC 22,000 AIC 10,000 AIC 22,000 AIC 10,000 AIC 22,000 AIC 10,000 AIC
PLUG-IN
PLUG-IN
PLUG-IN
PLUG-IN
BOLT-ON BOLT-ON BOLT-ON
100

UQFP-100

UQFPH-100 UQFP-M-100 UQFPH-M-100

UQFB-100

UQFBH-100 UQFB-100-X1

125

UQFP-125

UQFPH-125 UQFP-M-125 UQFPH-M-125

UQFB-125

UQFBH-125 UQFB-125-X1

150

UQFP-150

UQFPH-150 UQFP-M-150 UQFPH-M-150

UQFP-150

UQFBH-150 UQFP-150-X1

175

UQFP-175

UQFPH-175 UQFP-M-175 UQFPH-M-175

UQFB-175

UQFBH-175 UQFB-175-X1

200

UQFP-200

UQFPH-200 UQFP-M-200 UQFPH-M-200

UQFB-200

UQFBH-200 UQFB-200-X1

23

MISC.

6-350 kcmil
4-600 kcmil or
K1540 (2) 1/0-250 kcmil
4-600 kcmil or
K1540L (2) 1/0-250 kcmil
Non-rotating

K1

(3 per set) – 1 ∅

SUFFIX CATALOG #

24

CONDUIT AND AMPACITY INFORMATION

MAXIMUM NUMBER OF CONDUCTORS IN CONDUIT*
CONDUCTOR
SIZE
AWG,MCM

TYPE

CONDUIT AND AMPACITY INFORMATION

MISC.

RHW & RHH
(without outer covering)
THW

TW
THW
FEPB (6 thru 2),
RHW and
RHH
(without outer covering)
RH, THHW

CONDUIT TRADE SIZES (INCHES)
1

⁄4

1

11⁄4

11⁄2

2

21⁄2

3

⁄2

31⁄2

3

4

14
12
10
8

6
4
4
1

10
8
6
3

16
13
11
5

29
24
19
10

40
32
26
13

65
53
43
22

93
76
61
32

143 192
117 157
95 127 163
49
66
85

6

1

2

3

7

10

16

23

36

48

62

3

1

1

2

4

6

10

15

23

31

40

1
1
1

1
1
1
1

2
1
1
1

3
3
2
1

5
5
4
3

8
7
6
5

12
10
9
7

16
14
12
10

21
18
15
13

1
1

1
1
1
1
1

1
1
1
1
1

2
2
1
1
1

4
3
3
2
1

6
5
4
4
3

8
7
6
5
4

10
9
8
7
6

1
1
1

1
1
1

1
1
1

3
2
2

4
3
3

5
4
4

1/0
2/0
3/0
4/0
250
300
350
400
500
600
700
750

*This table is for concentric stranded conductors only. For cables with compact conductors refer to N.E.C.
* ALLOWABLE AMPACITIES OF INSULATED COPPER &
ALUMINUM CONDUCTORS (3W IN CONDUIT) 75°°C (167°°F)
*CU

AL or Cu-Clad AL

A

B

A

C

18
16
14
12
10
8

—
—
20
25
35
50

—
—
—
12
10
8

—
—
—
20
30
40

6
4
3
2
1

65
85
100
115
130

6
4
3
2
1

50
65
75
90
100

1/0
2/0
3/0
4/0

150
175
200
230

1/0
2/0
3/0
4/0

120
135
155
180

250
300
350
400
500

255
285
310
335
380

250
300
350
400
500

205
230
250
270
310

600
700
750

420
460
475

600
700
750

340
375
385

AMPACITY CORRECTION FACTORS

A = Size: AWG/MCM
B = Ampere Rating for
Insulation Types:
FEPW, RH, RHW,
THW, THWN, XHHW,
USE, 2W.
C = Ampere Rating for
Insulation Types:
RH, RHW, THW,
THWN, XHHW, USE
(Per NEC table 310-16)

AMBIENT
TEMP.C°°
21 - 25
26 - 30
31 - 35
36 - 40
41 - 45
46 - 50
51 - 55
56 - 60
61 - 65
66 - 70

CORRECTION
FACTOR
1.05
1.00
.94
.88
.82
.75
.67
.58
.33
—

AMBIENT
TEMP.F°°
70 - 77
79 - 86
88 - 95
97 - 104
106 - 113
115 - 122
124 - 131
133 - 140
142 - 158
160 - 176

Overall ampere ratings of UL Listed Milbank multiple position meter sockets are based on 1993
N.E.C. Manual article 220-32 and ANSI / UL-414 (except where restricted by line connector size).
These requirements provide for a diversity factor / demand factor being utilized in determining the overall (main bus / lug) rating of a gang socket. All Milbank UL Listed gang sockets meet or exceed these
diversity factor/demand factor requirements. Standard overall ampacity ratings for UL Listed and non
UL Listed gang sockets are as shown in the chart below. Ampere ratings of meter sockets are based
on the meter socket being wired with 75° C insulated wire conductor, sized in accordance with Table
310-16 of the National Electric Code.

GANG SOCKET OVERALL AMPACITIES
NO. OF METER
POSITIONS
2
3
4
5
6

100A / POS.
AMPACITY
200A
200A
200A
225A
270A

125A / POS.
AMPACITY
200A
225A
250A
285A
330A

150A / POS.
AMPACITY
200A
225A
270A
338A
396A

200A / POS.
AMPACITY
200A
270A
360A
450A
528A

 Unless otherwise permitted elsewhere in the Code, the overcurrent protection for conductor types marked with an obelisk () shall not exceed 15
amps for 14 AWG, 20 amps for 12 AWG, and 30 amps for 10 AWG copper: or 15 amps for 12 AWG and 25 amps for 10 AWG aluminum and
copper-clad aluminum after any correction factors for ambient temperature and number of conductors have been applied.
All meter sockets are 600 Volt rated unless otherwise noted.
All meter socket ampacity ratings are continuous duty unless otherwise noted.

24

ENERGIZATION OF ELECTRICAL EQUIPMENT

25

IMPORTANT NOTE
In addition to national and local electrical codes, many utilities have specific requirements for metering equipment. Always consult the serving utility for their specifications and requirements prior to ordering or installing
Milbank meter mounting equipment.

BEFORE ENERGIZING

A. Use caution and follow established safety procedures:
1) Wear safety apparel.
2) Use safety equipment.
3) Take action to prevent injury to yourself and others in the event of failure of the installation.
4) Take action to prevent/decrease damage to property in the event of failure of the installation.
5) If you are unsure how to safely energize the installation, get someone who is knowledgeable to do it.

AFTER ENERGIZING
A. Secure the installation:
1) To prevent accidental contact with energized parts, cover all openings with approved filler devices.
2) To prevent unauthorized access, secure all covers and/or doors with approved security devices.
3) Attach/post information to advise others of potential hazards associated with the installation.

RECOMMENDED TORQUE FOR GENERAL APPLICATIONS*
JOINT DESCRIPTION

NOMINAL
SIZE

SCREW

NUT

10
10
10
12
12
1/4
1/4
5/16
5/16
3/8
1/2

BRASS
STEEL
STEEL
STEEL
STEEL
STEEL
STEEL
STEEL
STEEL
STEEL
STEEL

Brass Nut or Extruded Hole
CU or AL Busbar <1/8″
Steel Nut or EH; CU or AL Busbar >1/8″

Aluminum Extruded Hole
Steel Nut or Extruded Hole
Aluminum Extruded Hole
Steel Nut or EH; CU or AL Busbar
Aluminum Extruded Hole
Steel Nut or EH; CU or AL Busbar
Steel Nut
Steel Nut

HEAD TYPE

TORQUE
( INCH LBS. )

ALL
ALL
ALL
ALL
ALL
ALL
ALL
HEX
HEX
HEX
HEX

20-25 in. lbs.
25-30 in. lbs
30-35 in. lbs
30-35 in. lbs
40-50 in. lbs.
40-50 in. lbs.
50-60 in. lbs.
60-70 in. lbs.
100-150 in. lbs.
150-200 in. lbs.
200-250 in. lbs.

*Interior labels typically indicate the required torque for wire connectors and studs, and should be referenced first.
EH: Extruded Hole
CU: Copper
AL: Aluminum

25

ENERGIZATION OF ELECTRICAL EQUIPMENT

WHEN ENERGIZING

MISC.

A. Give equipment a thorough visual examination to determine that:
1) No shipping or installation damage exists.
2) Proper clearances have been maintained.
3) All connections have been made.
4) Equipment is clean and dry.
B. Make a thorough examination to verify:
1) Tightness of all bolted connections (see table below).
2) Manually operate all circuit breakers, switches, relays, etc.
3) Check rigidity of all mountings, bus bars and components.
4) Use test equipment to check continuity of circuitry and integrity of insulation.
C. All switches and circuit breakers should be in the “off” position.
D. Verify that manual meter bypass (if applicable) is in non-bypass position.
E. Install cover and/or close doors.
F. If installation is not being energized at this time, follow “after-energizing” steps listed below. These
steps will secure the installation in case of accidental energization.

26

MATERIALS AND FINISHES

MATERIALS
STEEL QUALITY
The meter equipment listed in this catalog is made of galvanized steel (AISI* G90) to afford the
best possible weather proofing. *American Iron and Steel Institute.

MISC.

STEEL SHEET
16 gauge, galvanized, sheet: 1 1/4 oz./ sq.ft. class zinc-coated.
(AISI G90)
14 gauge, galvanized, sheet: 1 1/4 oz./ sq.ft. class zinc-coated.

ALUMINUM EXTRUSION
Wire-Terminals: Alloy; 6061-T6, Tin-plated for CU/AL wire.
Bus Bar: Alloy; 6101-o & 6063-O

MATERIALS AND FINISHES

ALUMINUM SHEET
3000 series aluminum sheet, H14, or 5052 series aluminum sheet, H32. Where applicable thicknesses range from .064 — .125

COPPER SHEET & BUS
Electrolytic copper with tin plating in most applications.

INSULATING MATERIALS
• In most units, support bases for current-carrying components are molded from fiberglass reinforced high-strength, track resistant, thermoset polyester molding compounds.
• Clear or black safety shields and polarity barriers are molded from high-strength, track resistant,
polycarbonate molding compounds.
• Various sheet insulating materials, as appropriate for the application are utilized in the fabrication of flat, formed and punched component parts and barriers.

FINISH
PROCESS
Light gray “state of the art” electrostatically applied powder paint offers a durable, non-fading
finish. For further information concerning the chemical analysis of the weather resistant finish,
please contact the factory.

METAL FASTENERS
Zinc-coated with a chromate dip.

RATING
NEMA RATING
All Milbank meter sockets, CT cans and meter socket / breaker units have a Type 3R rating.

26

WATTHOUR METERS–STANDARD FORMS–TRANSFORMER RATED OR SELF-CONTAINED

SC
2 and 3-WIRE FORMS
1S & 2S

SC
2 and 3-WIRE FORMS
1S & 2S with BYPASS

TR

TR

2-WIRE FORM 3S
5th Term. 9 o'clock

2-WIRE FORM 3S
with BYPASS

27

TR
2-WIRE FORM 3S
5th Term.6 o'clock

MISC.

SC

SC

SC

2-WIRE FORM 3S
with BYPASS

2 ELEMENT
3-WIRE NETWORK
FORM 12S 5th
TERM. 9 o'clock

2 ELEMENT 3-WIRE
NETWORK FORM 12S
with BYPASS
5th Term. 9 o'clock

2 ELEMENT
3-WIRE NETWORK
FORM 12S 5th
TERM. 6 o'clock

TR

TR

SC

3-WIRE FORM 4S

3-WIRE FORM 4S
WITH BYPASS

2 or 3 ELEMENT
3∅4W Y or Δ
Y FORM 14S
Δ FORM 15S

SC
2 or 3 ELEMENT
3∅4W Y or Δ
FORMS 14S & 15S
with BYPASS

SC
2 ELEMENT 3-WIRE
NETWORK FORM 12S
with BYPASS
5th Term. 6 o'clock

TR
2 ELEMENT
3∅4W Y or Δ
Y FORM 7S
Δ FORM 24S
with BYPASS

TR

TR

SC

SC

TR

2 ELEMENT
2∅3W, 2∅4W, 3∅3W
FORM 5S

2 ELEMENT 2∅3W,
2∅4W, 3∅3W
FORM 5S with
BYPASS

2 ELEMENT
2∅3W, 2∅4W, 3∅3W
FORM 13S

2 or 3 ELEMENT
2∅3W, 2∅4W, 3∅3W
FORM 13S with
BYPASS

2 or 3 ELEMENT
3∅4W Y or Δ
Y FORM 9S
Δ FORM 8S

TR

TR

TR

2 ELEMENT
3∅4W Y
FORM 6S

2 ELEMENT
3∅4W Y
FORM 6S
with BYPASS

TR = TRANSFORMER RATED
SC = SELF CONTAINED

2 or 3 ELEMENT
3∅4W Y or Δ
FORMS 8S & 9S
with BYPASS

Utility requirements for this equipment may vary. Always consult the serving utility for their requirements before ordering or
installing equipment in this catalog.

27

WATTHOUR METERS–STANDARD FORMS–TRANSFORMER RATED OR SELF-CONTAINED

TR

28

ADDITIONAL MILBANK PRODUCTS

ADDITIONAL MILBANK PRODUCTS

MISC

Other quality products available from Milbank

In addition to your local utility’s meter mounting
equipment, Milbank also manufactures
supporting products, such as...

Air Conditioner Disconnects
Hot Tub Disconnects
RV/Mobile Home Power Outlets
Terminal Boxes
Temporary Power Outlets
Commercial Pedestals
Commercial Enclosures
CT Enclosures
Circuit Breakers
Distribution Unit Substations
Enclosed Circuit Breakers
Safety Switches
Test Switches
Contact your local distributor or go to
www.milbankmfg.com
to find additional product literature.
28

INDEX

PG

CAT. NO.

PG

CAT. NO.

PG

6003 . . . . . . . . . . . . . . . . . . . . . . . . .22

MR-4 . . . . . . . . . . . . . . . . . . . . . . . . .23

U7021-RL-TG-KK . . . . . . . . . . . . . . . .8

5T24R . . . . . . . . . . . . . . . . . . . . . . . .22

MR-8 . . . . . . . . . . . . . . . . . . . . . . . . .23

U7040-RL-TG-KK . . . . . . . . . . . . . . . .8

5T8K2 . . . . . . . . . . . . . . . . . . . . . . . .22

NU8980-O-100-KK . . . . . . . . . . . . . .19

U7375-RL-KK . . . . . . . . . . . . . . . . . .18

A7514 . . . . . . . . . . . . . . . . . . . . . . . .22

NU8980-O-100-KK-LP . . . . . . . . . . .19

U7487-RL-TG-KK . . . . . . . . . . . . . . . .7

A7515 . . . . . . . . . . . . . . . . . . . . . . . .22

NU8980-O-200-KK . . . . . . . . . . . . . .19

U7607-RL-200-KK . . . . . . . . . . . . . .18

A7516 . . . . . . . . . . . . . . . . . . . . . . . .22

NU8980-O-200-KK-LP . . . . . . . . . . .19

U8436-O . . . . . . . . . . . . . . . . . . . . . .16

A7517 . . . . . . . . . . . . . . . . . . . . . . . .22

S1848 . . . . . . . . . . . . . . . . . . . . . . . .22

U8949-RL-TG-KK . . . . . . . . . . . . . . . .8

A7518 . . . . . . . . . . . . . . . . . . . . . . . .22

S2291-TO . . . . . . . . . . . . . . . . . . . . .15

U9107-O . . . . . . . . . . . . . . . . . . . . . .17

A7551 . . . . . . . . . . . . . . . . . . . . . . . .22

S2571 . . . . . . . . . . . . . . . . . . . . .15, 22

U9108-O . . . . . . . . . . . . . . . . . . . . . .17

A8110 . . . . . . . . . . . . . . . . . . . . . . . .22

S3488 . . . . . . . . . . . . . . . . . . . . . . . .22

U9550-RL . . . . . . . . . . . . . . . . . . . . . .9

A8111 . . . . . . . . . . . . . . . . . . . . . . . .22

S8324 . . . . . . . . . . . . . . . . . . . . . . . .22

U9551-O . . . . . . . . . . . . . . . . . . . . . . .9

A8112 . . . . . . . . . . . . . . . . . . . . . . . .22

S8988 . . . . . . . . . . . . . . . . . . . . . . . .22

U9700-RRL . . . . . . . . . . . . . . . . . . . . .9

A9064 . . . . . . . . . . . . . . . . . . . . . . . .22

U1252-X-KK . . . . . . . . . . . . . . . . . . .12

U9701-O . . . . . . . . . . . . . . . . . . . . . . .9

CP-21 . . . . . . . . . . . . . . . . . . . . . . . .22

U1253-X-KK . . . . . . . . . . . . . . . . . . .12

UQFB-100 . . . . . . . . . . . . . . . . . . . . .37

K1047 . . . . . . . . . . . . . . . . . . . . . . . .23

U1254-X-KK . . . . . . . . . . . . . . . . . . .12

UQFB-100-X1 . . . . . . . . . . . . . . . . . .37

K1350 . . . . . . . . . . . . . . . . . . . . .14,23

U1255-X-KK . . . . . . . . . . . . . . . . . . .12

UQFB-125 . . . . . . . . . . . . . . . . . . . . .37

K1350L . . . . . . . . . . . . . . . . . . . . . . .23

U1256-X-KK . . . . . . . . . . . . . . . . . . .12

UQFB-125-X1 . . . . . . . . . . . . . . . . . .37

K1539 . . . . . . . . . . . . . . . . . . . . .14, 23

U1748-O-WI . . . . . . . . . . . . . . . . . . .20

UQFB-150 . . . . . . . . . . . . . . . . . . . . .37

K1540 . . . . . . . . . . . . . . . . . . . . .14, 23

U1779-RRL . . . . . . . . . . . . . . . . . . . .10

UQFB-150-X1 . . . . . . . . . . . . . . . . . .37

K1540L . . . . . . . . . . . . . . . . . . . . . . .23

U1980-O-KK . . . . . . . . . . . . . . . . . . . .8

UQFB-175 . . . . . . . . . . . . . . . . . . . . .37

K1541 . . . . . . . . . . . . . . . . . . . . .14, 23

U2594-X-K7-INV . . . . . . . . . . . . . . . .11

UQFB-175-X1 . . . . . . . . . . . . . . . . . .37

K2381 . . . . . . . . . . . . . . . . . . . . .15, 22

U2732-XT-PED . . . . . . . . . . . . . . . . .13

UQFB-200 . . . . . . . . . . . . . . . . . . . . .37

K3082 . . . . . . . . . . . . . . . . . . . . . . . .23

U2733-XT-PED . . . . . . . . . . . . . . . . .13

UQFB-200-X1 . . . . . . . . . . . . . . . . . .37

K3083 . . . . . . . . . . . . . . . . . . . . . . . .23

U2734-XT-PED . . . . . . . . . . . . . . . . .13

UQFBH-100 . . . . . . . . . . . . . . . . . . .37

K3235 . . . . . . . . . . . . . . . . . . . . . . . .22

U2852-X-KK-K1-PED . . . . . . . . . . . .14

UQFBH-125 . . . . . . . . . . . . . . . . . . .37

K3441 . . . . . . . . . . . . . . . . . . . . . . . .23

U2853-X-KK-K1-PED . . . . . . . . . . . .14

UQFBH-150 . . . . . . . . . . . . . . . . . . .37

K3442 . . . . . . . . . . . . . . . . . . . . . . . .23

U2854-X-KK-PED . . . . . . . . . . . . . . .14

UQFBH-175 . . . . . . . . . . . . . . . . . . .37

K3865 . . . . . . . . . . . . . . . . . . . . . . . .22

U2855-X-KK-PED . . . . . . . . . . . . . . .14

UQFBH-200 . . . . . . . . . . . . . . . . . . .37

K4509 . . . . . . . . . . . . . . . . . . . . . . . .23

U2856-X-KK-PED . . . . . . . . . . . . . . .14

UQFP-100 . . . . . . . . . . . . . . . . . . . . .37

K4694 . . . . . . . . . . . . . . . . . . . . . . . .22

U2862-X-KK-K1-PED . . . . . . . . . . . .14

UQFP-125 . . . . . . . . . . . . . . . . . . . . .37

K4695 . . . . . . . . . . . . . . . . . . . . . . . .22

U2863-X-KK-K1-PED . . . . . . . . . . . .14

UQFP-150 . . . . . . . . . . . . . . . . . . . . .37

K5035 . . . . . . . . . . . . . . . . . . . . . . . .21

U2864-X-KK-PED . . . . . . . . . . . . . . .14

UQFP-175 . . . . . . . . . . . . . . . . . . . . .37

K5086 . . . . . . . . . . . . . . . . . . . . . . . .22

U2865-X-KK-PED . . . . . . . . . . . . . . .14

UQFP-200 . . . . . . . . . . . . . . . . . . . . .37

K5193 . . . . . . . . . . . . . . . . . . . . . . . .21

U2866-X-KK-PED . . . . . . . . . . . . . . .14

UQFPH-100 . . . . . . . . . . . . . . . . . . .37

K5400-1450 . . . . . . . . . . . . . . . . . . .21

U3000-O-K3L-K2L . . . . . . . . . . . . . .10

UQFPH-125 . . . . . . . . . . . . . . . . . . .37

K5400-520 . . . . . . . . . . . . . . . . . . . .21

U3800 . . . . . . . . . . . . . . . . . . . . . . . . .5

UQFPH-150 . . . . . . . . . . . . . . . . . . .37

K5400-520GR . . . . . . . . . . . . . . . . . .21

U3803 . . . . . . . . . . . . . . . . . . . . . . . . .5

UQFPH-175 . . . . . . . . . . . . . . . . . . .37

K5400-BRIDGE-1POS . . . . . . . . . . .21

U3806 . . . . . . . . . . . . . . . . . . . . . . . . .5

UQFPH-200 . . . . . . . . . . . . . . . . . . .37

K5400-BRIDGE-2POS . . . . . . . . . . .21

U3822-20GR . . . . . . . . . . . . . . . . . . . .6

UQFPH-M-100 . . . . . . . . . . . . . . . . .37

K5400-TT30 . . . . . . . . . . . . . . . . . . .21

U3849-O-2/200-INV . . . . . . . . . . . . .20

UQFPH-M-125 . . . . . . . . . . . . . . . . .37

K5415 . . . . . . . . . . . . . . . . . . . . . . . .21

U4881-O . . . . . . . . . . . . . . . . . . . . . . .6

UQFPH-M-150 . . . . . . . . . . . . . . . . .37

K5800 . . . . . . . . . . . . . . . . . . . . . . . .22

U4881-O-50GB . . . . . . . . . . . . . . . . . .6

UQFPH-M-175 . . . . . . . . . . . . . . . . .37

K5T . . . . . . . . . . . . . . . . . . . . . . .21, 22

U4881-O-60GB . . . . . . . . . . . . . . . . . .6

UQFPH-M-200 . . . . . . . . . . . . . . . . .37

L572-XL-KK . . . . . . . . . . . . . . . . . . .12

U5136-O-100S . . . . . . . . . . . . . . . . .21

UQFP-M-100 . . . . . . . . . . . . . . . . . .37

L573-XL-KK . . . . . . . . . . . . . . . . . . .12

U5136-O-200S . . . . . . . . . . . . . . . . .21

UQFP-M-125 . . . . . . . . . . . . . . . . . .37

L574-XL-KK . . . . . . . . . . . . . . . . . . .12

U5136-O-200S/22 . . . . . . . . . . . . . . .21

UQFP-M-150 . . . . . . . . . . . . . . . . . .37

L575-XL-KK . . . . . . . . . . . . . . . . . . .12

U5137-O-100S . . . . . . . . . . . . . . . . .21

UQFP-M-175 . . . . . . . . . . . . . . . . . .37

L576-XL-KK . . . . . . . . . . . . . . . . . . .12

U5137-O-200S . . . . . . . . . . . . . . . . .21

UQFP-M-200 . . . . . . . . . . . . . . . . . .37

M5-144 . . . . . . . . . . . . . . . . . . . . . . .23

U5137-O-200S/22 . . . . . . . . . . . . . . .21

29

INDEX

CAT. NO.

29

NOTES

NOTES

30

30

NOTES

31
NOTES

31

Meter Mounting Equipment & More!
Commercial Electrical Enclosures
Residential & Commercial Metering
Commercial Meter Pedestals
Disconnect Devices
Current Transformer Enclosures
RV/MH Pedestals
Temporary Power Outlets
Circuit Breakers
Distribution Unit Substations
Enclosed Circuit Breakers
Safety Switches
Test Switches

REPRESENTATIVE
Callas/Kingsley
845 Lively Boulevard
Wood Dale, IL 60191
Tel: 630-595-7887 Fax: 630-595-6922
www.ckelectricalsales.com

MILBANK MFG. CO.
PO Box 419028
Kansas City, MO 64141-0028
Tel: 816-483-5314 Fax: 816-483-6357
Toll Free: 877-483-5314
www.milbankmfg.com

www.milbankmfg.com

NIPSCO 11/06 (1K)



Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.6
Linearized                      : No
XMP Toolkit                     : 3.1-701
Producer                        : Acrobat Distiller 7.0.5 for Macintosh
Create Date                     : 2006:11:27 10:58:50-06:00
Modify Date                     : 2007:01:11 16:52:24-06:00
Creator Tool                    : QuarkXPress: pictwpstops filter 1.0
Metadata Date                   : 2007:01:11 16:52:24-06:00
Format                          : application/pdf
Title                           : NIPSCO 11 06 w rep
Creator                         : Melisa J Burns
Document ID                     : uuid:9ee8819a-7e38-11db-94ba-000a95b001fc
Instance ID                     : uuid:67492f3a-a1c6-11db-8f9a-000a95b001fc
Has XFA                         : No
Page Count                      : 32
Author                          : Melisa J Burns
EXIF Metadata provided by EXIF.tools

Navigation menu