Fl2 Fl3 L2323.qxp
2014-06-03
: Pdf 259325-Attachment 259325-Attachment 746504 Batch4 unilog
Open the PDF directly: View PDF .
Page Count: 2
Download | |
Open PDF In Browser | View PDF |
Type No. Job Name Catalog No. FL2-FL3 Shown: FL2OT Decorative Emergency Lighting 6 Volt, 11 Watts & 6 Volt, 17 Watt Maintenance Free, Sealed Lead Calcium Battery Housing • Constructed of impact resistant, UL 94 V-O, 5 VA thermoplastic, completely self contained • White housing is standard, with an optional black housing available • The FL3 offers the option of 6 W remote capability Electronics • 120/277 VAC dual voltage input with surge-protection • Solid-state charging circuitry provides for a reliable charging system • Brownout protection activates lights when AC voltage drops 20% below nominal • AC indicator lamp and test switch Battery • Maintenance free, sealed lead calcium battery has an expected service life of 5 years with an operating range of 68°F (20°C) to 104°F (40°C)* • Battery supplies 90 minutes of emergency power * Increases or decreases in temperature will affect battery performance and/or capacity. Optimum battery performance realized at 77°F (25°C) • Low voltage disconnect feature (LVD) prevents deep battery discharge Illumination • Illumination is provided by two fully adjustable polycarbonate 6 VDC, 5.4 W T-5 lamps • High impact acrylic refractors minimize glare and maximize optic control Warranty • Electronics: 3 years • Battery: 1 year full, 4 years pro-rata Electrical Specifications • 120 VAC: 60 Hz, 0.045 A • 277 VAC: 60 Hz, 0.020 A LightGuard is a Philips company Self-Testing Diagnostics (Optional) • Continuously monitors the critical functions of the equipment, including: battery disconnect, battery failure, charger failure, transformer failure and lamp failure • Self-Testing routine performs a one-minute test every 30 days, a 30-minute test on the 6th month and a 90-minute test annually Code Compliance • UL 924 listed • UL damp location listed standard 68°F (20°C) to 104°F (40°C) • NFPA 101, NEC, BOCA, OSHA, and IBC illumination standards Application • Corridors • Open Plan Office Areas • School Hallways, Lunch Rooms • Hotel, Retail and General Commercial Construction FL2-FL3 Ordering Information SERIES FL2 = 6 V, 11 W Emergency Lighting Unit FL3 = 6 V, 17 W Emergency Lighting Unit With 6 W Remote Capability Dimensions HOUSING COLOR FACTORY INSTALLED OPTIONS ACCESSORIES (Ordered Separately) Blank = White B = Black OT = Self-Diagnostics (available in white housing only) WG5 = Wire Guard 16.0” (40.6 cm) 5.0” (12.7 cm) 11.87” (30.15 cm) Dimensions are approximate and subject to change. Suggested Specification Furnish and install LightGuard decorative emergency lighting model _____________________________________. The unit shall be constructed to meet Underwriter’s Laboratories, Inc. Standard #924 and must be installed to conform to Article 700 of the National Electrical Code (NEC). INSTALLATION AND OPERATION - Unit shall be easily field connected to a 120 or 277 VAC, 60 Hz, unswitched power source. Installation must comply with the NEC as well as other applicable codes. Upon utility power failure or brownout, the unit shall automatically provide emergency battery power and maintain the stated illumination level and output wattage for a minimum period of 90 minutes. Upon restoration of utility power, the charging circuitry shall restore the battery to full charge within UL 924 requirements following a rated discharge of not more than 90 minutes.The unit shall be damp location listed standard. CHARGING CIRCUITRY - Unit shall utilize a solid-state, fully automatic, voltage regulated charging system which will maintain the battery at full capacity without the need for periodic exercising or equalization.The following features shall be standard: low voltage disconnect (LVD), brownout protection and AC lockout. BATTERY - The battery shall be maintenance free, sealed lead calcium with an optimum operating temperature range of 68°F (20°C) to 104°F (40°C). All normal gassing shall be contained within the battery casing, and will not escape into the atmosphere. Gasses created during recharge cycles will recombine with existing electrolyte.The battery shall have a recommended service life of 5 years when operated at optimum operating temperature. ILLUMINATION - The product shall incorporate two fully adjustable lamp heads, witch include a parabolic reflector design and utilize a 6 VDC, 5.4 W T-5 wedge base tungsten lamp.The lamp head lens shall be constructed of high impact, prismatic, UV stabilized acrylic, and will effectively control sight line glare. HOUSING - The housing shall be constructed of impact resistant, UL 94 V-0, white thermoplastic, completely self-contained. ALL SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE 272 West Stag Park Service Road • Burgaw, NC 28425 (910) 259-1131 • FAX (800) 403-6927 www.lightguard.com L2323R11 1/12 IH
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.4 Linearized : No XMP Toolkit : 3.1-702 Producer : Acrobat Distiller 7.0 (Windows) Create Date : 2009:06:03 15:25:30-04:00 Creator Tool : PScript5.dll Version 5.2.2 Modify Date : 2012:02:23 15:24:38-05:00 Metadata Date : 2012:02:23 15:24:38-05:00 Format : application/pdf Title : fl2-fl3 l2323.qxp Creator : KNarusewicz Document ID : uuid:8579bb82-d327-490a-91d6-9fe7328b9916 Instance ID : uuid:6d9bec23-b149-40d7-9c1f-f7f1867a4beb Has XFA : No Page Count : 2 Author : KNarusewiczEXIF Metadata provided by EXIF.tools