ABB Miniature Circuit Breakers Catalog
2014-06-03
: Pdf 34164-Attachment 34164-Attachment 804325 Batch4 unilog
Open the PDF directly: View PDF .
Page Count: 96
Download | |
Open PDF In Browser | View PDF |
Miniature circuit breakers Index M ini at br ure ea ci ke rcu rs it 15 - Miniature circuit breakers S200 Miniature circuit breakers...............................15.1 - 15.42 UL 489 Series Ordering details Description...............................................................................................................15.1 Features...................................................................................................................15.1 S200U-K, 240 VAC..................................................................................................15.2 S200U-Z, 240 VAC..................................................................................................15.3 S200UP-K, 480Y/277 VAC......................................................................................15.4 S200UP-Z, 480Y/277 VAC.......................................................................................15.5 SU200PR-K, 480Y/277 VAC....................................................................................15.6 S200UDC-K, 1 pole 60 VDC, 2 pole 125 VDC.........................................................15.7 S200UDC-Z, 1 pole 60 VDC, 2 pole 125 VDC..........................................................15.8 Accessories..........................................................................................................15.9 - 15.12 Technical data.....................................................................................................15.13 - 15.15 Dimensions.....................................................................................................................15.16 UL 1077 Series Ordering details Description & features............................................................................................15.17 S200-B, 480Y/277 VAC.........................................................................................15.18 S200-C, 480Y/277 VAC........................................................................................15.19 S200-D, 480Y/277 VAC.........................................................................................15.20 S200-K, 480Y/277 VAC.........................................................................................15.21 S200-Z, 480Y/277 VAC.........................................................................................15.22 S200P-B, 480Y/277 VAC.......................................................................................15.23 S200P-C, 480Y/277 VAC.......................................................................................15.24 S200P-D, 480Y/277 VAC.......................................................................................15.25 S200P-K, 480Y/277 VAC.......................................................................................15.26 S200P-Z, 480Y/277 VAC.......................................................................................15.27 S200PR-K, 240 VAC, Ring tongue.........................................................................15.28 S280UC-K, 500 VDC.............................................................................................15.29 S280UC-Z, 500 VDC.............................................................................................15.30 Accessories........................................................................................................15.31 - 15.39 Technical data.....................................................................................................15.40 - 15.42 Dimensions.........................................................................................................15.43 - 15.44 S800 Miniature circuit breakers.............................15.53 - 15.80 UL 489 Series Ordering details Description & features............................................................................................15.53 S800U-K, 240 VAC................................................................................................15.54 S800U-Z, 240 VAC................................................................................................15.55 S803W-SCL-SR UL Short circuit current limiter..........................................15.56 - 15.57 S800W-RSU Remote sensing unit.........................................................................15.58 IEC Series Ordering details Description & features............................................................................................15.59 S800S-B, 690 VAC................................................................................................15.60 S800S-C, 690 VAC................................................................................................15.61 S800S-D, 690 VAC................................................................................................15.62 S800S-K, 690 VAC................................................................................................15.63 UL & IEC Series Accessories........................................................................................................15.64 - 15.65 Technical data.....................................................................................................15.67 - 15.78 Dimensions.....................................................................................................................15.79 S500 Miniature circuit breakers.............................15.81 - 15.87 Ordering details Description & features............................................................................................15.81 S500-K, UL 600Y/277 VAC / IEC 690 VAC............................................................15.82 S500UC-B, 250 VDC per pole (600 VDC 4P).........................................................15.83 S500UC-K, 250 VDC per pole (600 VDC 4P).........................................................15.84 Accessories....................................................................................................................15.85 Technical data.................................................................................................................15.86 Dimensions.....................................................................................................................15.87 Technical data.........................................................15.89 - 15.97 Application guide...................................................15.45 - 15.52 Introduction, overload, short circuit, breaker definition.....................................................15.45 Circuit breaker construction................................................................................15.46 - 15.47 Circuit breaker current limitation..........................................................................15.48 - 15.49 Selective coordination and series ratings.............................................................15.50 - 15.51 Miniature circuit breaker cutaway....................................................................................15.52 Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com 15 cir Min cu ia it b tur S2 rea e 00 ke r S200 UL 489 Series Miniature circuit breakers S200 UL 489 Series s Description Features The S200 Series miniature circuit breaker offers a compact solution for protection requirements. The S200U AND S200UP devices are UL 489 tested current limiting and DIN rail mounted. The S200U and S200UP is available with application-specific trip characteristics to provide maximum circuit protection. The breakers offer thermal-magnetic trip protection according to K and Z characteristics. For the worldwide market, the breakers carry UL, CSA, IEC, CE and many other agency approvals and certifications. • UL current limiting • Fast breaking time (2.3 – 2.5 ms) • Bus connection system • Wide range of accessories • Available with variable depth handle mechanism • CE certified and marked • DIN rail mounting • Finger safe terminals • Multi-function terminals • Suitable for reverse feed but S200UDC has polarity • UL 489 Listed - branch circuit protective device. UL File #E212323 S200U Amperage 0.2 – 63 Voltage Poles S200UP SU200PR S200UDC 0.2 – 25 0.2 – 35A ; 40 – 63A 1 – 63 240 VAC 480Y/277VAC 480Y/277 VAC ; 240 VAC 60-125 VDC 1, 2, 3, 4 1, 2, 3, 4 1, 2, 3, 4 1, 2 Trip characteristics K, Z K, Z K K, Z Interrupting ratings Up to 25 kA : IEC 60947-2 10 kA : UL 489 10 kA : CSA 22.2 No. 5 Up to 25 kA : IEC 60947-2 10 kA : UL 489 10 kA : CSA 22.2 No. 5 10kA: UL489 10kA: CSA 22.2 No.5 14 kA : UL489 14 kA: CSA 22.2 No. 5 Auxiliary contacts Yes Yes Yes Yes Bell alarm Yes Yes Yes Yes Shunt trip Yes Yes Yes Yes Bus bar Yes Yes No Yes Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com 15 re s tu ker a i in ea M it br 0 cu S20 cir K S200U-K, 240 VAC Branch circuit protection UL 489, CSA 22.2 No. 5 No. of poles 1 S201U-K 2 S202U-K 15 Rated current 0.2 0.3 0.5 0.75 1 1.6 2 3 4 5 6 8 10 15 16 20 25 30 32 40 50 60 63 0.2 0.3 0.5 0.75 1 1.6 2 3 4 5 6 8 10 15 16 20 25 30 32 40 50 60 63 Catalog number S201U-K0.2 S201U-K0.3 S201U-K0.5 S201U-K0.75 S201U-K1 S201U-K1.6 S201U-K2 S201U-K3 S201U-K4 S201U-K5 S201U-K6 S201U-K8 S201U-K10 S201U-K15 S201U-K16 S201U-K20 S201U-K25 S201U-K30 S201U-K32 S201U-K40 S201U-K50 S201U-K60 S201U-K63 S202U-K0.2 S202U-K0.3 S202U-K0.5 S202U-K0.75 S202U-K1 S202U-K1.6 S202U-K2 S202U-K3 S202U-K4 S202U-K5 S202U-K6 S202U-K8 S202U-K10 S202U-K15 S202U-K16 S202U-K20 S202U-K25 S202U-K30 S202U-K32 S202U-K40 S202U-K50 S202U-K60 S202U-K63 No. of poles 3 4 Rated current 0.2 0.3 0.5 0.75 1 1.6 2 3 4 5 6 8 10 15 16 20 25 30 32 40 50 60 63 0.2 0.3 0.5 0.75 1 1.6 2 3 4 5 6 8 10 15 16 20 25 30 32 40 50 60 63 Catalog number S203U-K0.2 S203U-K0.3 S203U-K0.5 S203U-K0.75 S203U-K1 S203U-K1.6 S203U-K2 S203U-K3 S203U-K4 S203U-K5 S203U-K6 S203U-K8 S203U-K10 S203U-K15 S203U-K16 S203U-K20 S203U-K25 S203U-K30 S203U-K32 S203U-K40 S203U-K50 S203U-K60 S203U-K63 S204U-K0.2 S204U-K0.3 S204U-K0.5 S204U-K0.75 S204U-K1 S204U-K1.6 S204U-K2 S204U-K3 S204U-K4 S204U-K5 S204U-K6 S204U-K8 S204U-K10 S204U-K15 S204U-K16 S204U-K20 S204U-K25 S204U-K30 S204U-K32 S204U-K40 S204U-K50 S204U-K60 S204U-K63 Tripping characteristic K UL 489 240 VAC 10 kA S203U-K Inductive loads • K Curve • Designed for allowing higher in-rush currents during system start up • Example: motors, transformers Accessories & technical data Accessories – See page 15.9 - 15.13 Technical data – See page 15.14 -15.16 S204U-K Note: This breaker for AC use only Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com cir Min cu ia it b tur S2 rea e 00 ke r S200U-Z, 240 VAC Branch circuit protection UL 489, CSA 22.2 No. 5 Z No. of poles 1 S201U-Z 2 S202U-Z Rated current 0.5 1 1.6 2 3 4 5 6 8 10 15 16 20 25 30 32 40 50 60 63 0.5 1 1.6 2 3 4 5 6 8 10 15 16 20 25 30 32 40 50 60 63 Catalog number S201U-Z0.5 S201U-Z1 S201U-Z1.6 S201U-Z2 S201U-Z3 S201U-Z4 S201U-Z5 S201U-Z6 S201U-Z8 S201U-Z10 S201U-Z15 S201U-Z16 S201U-Z20 S201U-Z25 S201U-Z30 S201U-Z32 S201U-Z40 S201U-Z50 S201U-Z60 S201U-Z63 S202U-Z0.5 S202U-Z1 S202U-Z1.6 S202U-Z2 S202U-Z3 S202U-Z4 S202U-Z5 S202U-Z6 S202U-Z8 S202U-Z10 S202U-Z15 S202U-Z16 S202U-Z20 S202U-Z25 S202U-Z30 S202U-Z32 S202U-Z40 S202U-Z50 S202U-Z60 S202U-Z63 s No. of poles 3 4 Rated current 0.5 1 1.6 2 3 4 5 6 8 10 15 16 20 25 30 32 40 50 60 63 0.5 1 1.6 2 3 4 5 6 8 10 15 16 20 25 30 32 40 50 60 63 Catalog number S203U-Z0.5 S203U-Z1 S203U-Z1.6 S203U-Z2 S203U-Z3 S203U-Z4 S203U-Z5 S203U-Z6 S203U-Z8 S203U-Z10 S203U-Z15 S203U-Z16 S203U-Z20 S203U-Z25 S203U-Z30 S203U-Z32 S203U-Z40 S203U-Z50 S203U-Z60 S203U-Z63 S204U-Z0.5 S204U-Z1 S204U-Z1.6 S204U-Z2 S204U-Z3 S204U-Z4 S204U-Z5 S204U-Z6 S204U-Z8 S204U-Z10 S204U-Z15 S204U-Z16 S204U-Z20 S204U-Z25 S204U-Z30 S204U-Z32 S204U-Z40 S204U-Z50 S204U-Z60 S204U-Z63 Tripping characteristic Z UL 489 240 VAC 10 kA Resistive loads • Z Curve • Designed to provide maximum protection with a very low short circuit trip setting • Example: semiconductors, control circuits S203U-Z Accessories & technical data Accessories – See page 15.9 - 15.13 Technical data – See page 15.14 -15.16 S204U-Z Note: This breaker for AC use only Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com 15 re s tu ker a i in ea M it br 0 cu S20 cir K S200UP-K, 480Y/277 VAC Branch circuit protection UL 489, CSA 22.2 No. 5 No. of poles 1 S201UP-K 2 Rated current Catalog number 0.2 0.3 0.5 0.75 1 1.6 2 3 4 5 6 8 10 15 16 20 25 0.2 0.3 0.5 0.75 1 1.6 2 3 4 5 6 8 10 15 16 20 25 S201UP-K0.2 S201UP-K0.3 S201UP-K0.5 S201UP-K0.75 S201UP-K1 S201UP-K1.6 S201UP-K2 S201UP-K3 S201UP-K4 S201UP-K5 S201UP-K6 S201UP-K8 S201UP-K10 S201UP-K15 S201UP-K16 S201UP-K20 S201UP-K25 S202UP-K0.2 S202UP-K0.3 S202UP-K0.5 S202UP-K0.75 S202UP-K1 S202UP-K1.6 S202UP-K2 S202UP-K3 S202UP-K4 S202UP-K5 S202UP-K6 S202UP-K8 S202UP-K10 S202UP-K15 S202UP-K16 S202UP-K20 S202UP-K25 No. of poles 3 4 Rated current 0.2 0.3 0.5 0.75 1 1.6 2 3 4 5 6 8 10 15 16 20 25 0.2 0.3 0.5 0.75 1 1.6 2 3 4 5 6 8 10 15 16 20 25 Catalog number S203UP-K0.2 S203UP-K0.3 S203UP-K0.5 S203UP-K0.75 S203UP-K1 S203UP-K1.6 S203UP-K2 S203UP-K3 S203UP-K4 S203UP-K5 S203UP-K6 S203UP-K8 S203UP-K10 S203UP-K15 S203UP-K16 S203UP-K20 S203UP-K25 S204UP-K0.2 S204UP-K0.3 S204UP-K0.5 S204UP-K0.75 S204UP-K1 S204UP-K1.6 S204UP-K2 S204UP-K3 S204UP-K4 S204UP-K5 S204UP-K6 S204UP-K8 S204UP-K10 S204UP-K15 S204UP-K16 S204UP-K20 S204UP-K25 Tripping characteristic K S202UP-K UL 489 480Y/277 VAC 10 kA Inductive loads • K Curve • Designed for allowing higher in-rush currents during system start up • Example: motors, transformers 15 Accessories & technical data Accessories – See page 15.9 - 15.13 Technical data – See page 15.14 -15.16 S203UP-K S204UP-K Note: This breaker for AC use only Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com cir Min cu ia it b tur S2 rea e 00 ke r S200UP-Z, 480Y/277 VAC Branch circuit protection UL 489, CSA 22.2 No. 5 Z No. of poles 1 S201UP-Z 2 Rated current 0.5 1 1.6 2 3 4 5 6 8 10 15 16 20 25 0.5 1 1.6 2 3 4 5 6 8 10 15 16 20 25 Catalog number S201UP-Z0.5 S201UP-Z1 S201UP-Z1.6 S201UP-Z2 S201UP-Z3 S201UP-Z4 S201UP-Z5 S201UP-Z6 S201UP-Z8 S201UP-Z10 S201UP-Z15 S201UP-Z16 S201UP-Z20 S201UP-Z25 S202UP-Z0.5 S202UP-Z1 S202UP-Z1.6 S202UP-Z2 S202UP-Z3 S202UP-Z4 S202UP-Z5 S202UP-Z6 S202UP-Z8 S202UP-Z10 S202UP-Z15 S202UP-Z16 S202UP-Z20 S202UP-Z25 s No. of poles 3 4 Rated current 0.5 1 1.6 2 3 4 5 6 8 10 15 16 20 25 0.5 1 1.6 2 3 4 5 6 8 10 15 16 20 25 Catalog number S203UP-Z0.5 S203UP-Z1 S203UP-Z1.6 S203UP-Z2 S203UP-Z3 S203UP-Z4 S203UP-Z5 S203UP-Z6 S203UP-Z8 S203UP-Z10 S203UP-Z15 S203UP-Z16 S203UP-Z20 S203UP-Z25 S204UP-Z0.5 S204UP-Z1 S204UP-Z1.6 S204UP-Z2 S204UP-Z3 S204UP-Z4 S204UP-Z5 S204UP-Z6 S204UP-Z8 S204UP-Z10 S204UP-Z15 S204UP-Z16 S204UP-Z20 S204UP-Z25 Tripping characteristic Z UL 489 480Y/277 VAC 10 kA S202UP-Z Resistive loads • Z Curve • Designed to provide maximum protection with a very low short circuit trip setting • Example: semiconductors, control circuits Accessories & technical data Accessories – See page 15.9 - 15.13 Technical data – See page 15.14 -15.16 S203UP-Z S204UP-Z Note: This breaker for AC use only Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com 15 re s tu ker a i in ea M it br 0 cu S20 cir K SU200PR-K, 480Y/277 VAC, Ring tongue Branch circuit protection UL489, CSA 22.2 No.5 No. of poles 1 SU201PR-K0.2 SU202PR-K0.2 2 15 SU203PR-K0.2 Rated current 0.2 0.3 0.5 0.75 1 1.6 2 3 4 5 6 8 10 13 15 16 20 25 30 32 35 40 50 60 63 0.2 0.3 0.5 0.75 1 1.6 2 3 4 5 6 8 10 13 15 16 20 25 30 32 35 40 50 60 63 Catalog number SU201PR-K0.2 SU201PR-K0.3 SU201PR-K0.5 SU201PR-K0.75 SU201PR-K1 SU201PR-K1.6 SU201PR-K2 SU201PR-K3 SU201PR-K4 SU201PR-K5 SU201PR-K6 SU201PR-K8 SU201PR-K10 SU201PR-K13 SU201PR-K15 SU201PR-K16 SU201PR-K20 SU201PR-K25 SU201PR-K30 SU201PR-K32 SU201PR-K35 SU201PR-K40 SU201PR-K50 SU201PR-K60 SU201PR-K63 SU202PR-K0.2 SU202PR-K0.3 SU202PR-K0.5 SU202PR-K0.75 SU202PR-K1 SU202PR-K1.6 SU202PR-K2 SU202PR-K3 SU202PR-K4 SU202PR-K5 SU202PR-K6 SU202PR-K8 SU202PR-K10 SU202PR-K13 SU202PR-K15 SU202PR-K16 SU202PR-K20 SU202PR-K25 SU202PR-K30 SU202PR-K32 SU202PR-K35 SU202PR-K40 SU202PR-K50 SU202PR-K60 SU202PR-K63 No. of poles 3 4 K characteristic Rated current Catalog number 0.2 0.3 0.5 0.75 1 1.6 2 3 4 5 6 8 10 13 15 16 20 25 30 32 35 40 50 60 63 0.2 0.3 0.5 0.75 1 1.6 2 3 4 5 6 8 10 13 15 16 20 25 30 32 35 40 50 60 63 SU203PR-K0.2 SU203PR-K0.3 SU203PR-K0.5 SU203PR-K0.75 SU203PR-K1 SU203PR-K1.6 SU203PR-K2 SU203PR-K3 SU203PR-K4 SU203PR-K5 SU203PR-K6 SU203PR-K8 SU203PR-K10 SU203PR-K13 SU203PR-K15 SU203PR-K16 SU203PR-K20 SU203PR-K25 SU203PR-K30 SU203PR-K32 SU203PR-K35 SU203PR-K40 SU203PR-K50 SU203PR-K60 SU203PR-K63 SU204PR-K0.2 SU204PR-K0.3 SU204PR-K0.5 SU204PR-K0.75 SU204PR-K1 SU204PR-K1.6 SU204PR-K2 SU204PR-K3 SU204PR-K4 SU204PR-K5 SU204PR-K6 SU204PR-K8 SU204PR-K10 SU204PR-K13 SU204PR-K15 SU204PR-K16 SU204PR-K20 SU204PR-K25 SU204PR-K30 SU204PR-K32 SU204PR-K35 SU204PR-K40 SU204PR-K50 SU204PR-K60 SU204PR-K63 Tripping characteristic K UL 489 480Y/277 VAC 10 kA Inductive loads • K Curve • Designed for allowing higher in-rush currents during system start up • Example: motors, transformers Accessories & technical data Accessories – See page 15.9 - 15.13 Technical data – See page 15.14 -15.16 SU204PR-K0.2 Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com cir Min cu ia it b tur S2 rea e 00 ke r S200UDC-K, 1 pole 60 VDC, 2 pole 125 VDC Branch circuit protection UL 489, CSA 22.2 No. 5 K No. of poles Rated current Catalog number S202UDC-K1 Rated current 1 S201UDC-K1 1.6 S201UDC-K1.6 2 S201UDC-K2 3 S201UDC-K3 4 S201UDC-K4 5 S201UDC-K5 6 S201UDC-K6 8 S201UDC-K8 10 S201UDC-K10 13 S201UDC-K13 15 S201UDC-K15 16 S201UDC-K16 20 S201UDC-K20 25 S201UDC-K25 30 S201UDC-K30 32 S201UDC-K32 40 S201UDC-K40 50 S201UDC-K50 60 S201UDC-K60 63 S201UDC-K63 NOTE: Standard UL 489 (only DC; please note polarity of device). 1 S201UDC-K1 No. of poles Tripping characteristic K 60 40 I1 I1 = 1.0 x In I2 10 Minutes I2 = 1.35 x In ϑR = 25°C 1 = marginal characteristic measured in cold status 20 Tripping time Accessories & technical data S202UDC-K1 S202UDC-K1.6 S202UDC-K2 S202UDC-K3 S202UDC-K4 S202UDC-K5 S202UDC-K6 S202UDC-K8 S202UDC-K10 S202UDC-K13 S202UDC-K15 S202UDC-K16 S202UDC-K20 S202UDC-K25 S202UDC-K30 S202UDC-K32 S202UDC-K40 S202UDC-K50 S202UDC-K60 S202UDC-K63 120 UL 489 480Y/277 VAC 14 kA Inductive loads • K Curve • Designed for allowing higher in-rush currents during system start up • Example: motors, transformers Catalog number 1 1.6 2 3 4 5 6 8 10 13 15 16 20 25 30 32 40 50 60 63 2 s 1 6 1 4 2 K 1 40 20 Accessories – See page 15.9 - 15.13 Technical data – See page 15.14 -15.16 Seconds 10 6 4 2 1 0.6 0.4 15 0.2 DC 0.1 0.06 0.04 0.02 0.01 1 1.5 2 3 4 5 6 8 10 15 20 30 14 25 Multiple of rated current Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com re s tu ker a i in ea M it br 0 cu S20 cir S200UDC-Z, 1 pole 60 VDC, 2 pole 125 VDC Branch circuit protection UL 489, CSA 22.2 No. 5 Z No. of poles 1 S201UDC-K1 S202UDC-K1 Rated current 1 1.6 2 3 4 5 6 8 10 13 15 16 20 25 30 32 40 50 60 63 Catalog number S201UDC-Z1 S201UDC-Z1.6 S201UDC-Z2 S201UDC-Z3 S201UDC-Z4 S201UDC-Z5 S201UDC-Z6 S201UDC-Z8 S201UDC-Z10 S201UDC-Z13 S201UDC-Z15 S201UDC-Z16 S201UDC-Z20 S201UDC-Z25 S201UDC-Z30 S201UDC-Z32 S201UDC-Z40 S201UDC-Z50 S201UDC-Z60 S201UDC-Z63 No. of poles 2 NOTE: Standard UL 489 (only DC; please note polarity of device). Rated current Catalog number 1 1.6 2 3 4 5 6 8 10 13 15 16 20 25 30 32 40 50 60 63 S202UDC-Z1 S202UDC-Z1.6 S202UDC-Z2 S202UDC-Z3 S202UDC-Z4 S202UDC-Z5 S202UDC-Z6 S202UDC-Z8 S202UDC-Z10 S202UDC-Z13 S202UDC-Z15 S202UDC-Z16 S202UDC-Z20 S202UDC-Z25 S202UDC-Z30 S202UDC-Z32 S202UDC-Z40 S202UDC-Z50 S202UDC-Z60 S202UDC-Z63 Z Tripping characteristic Z UL 489 480Y/277 VAC 14 kA Accessories – See page 15.9 - 15.13 Technical data – See page 15.14 -15.16 Minutes Tripping time Accessories & technical data Seconds Resistive loads • Z Curve • Designed to provide maximum protection with a very low short circuit trip setting • Example: semiconductors, control circuits marginal characteristic measured in cold status 15 Multiple of rated current Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com cir Min cu ia it b tur S2 rea e 00 ke r Accessories S200U, S200UP, SU200PR & S200UDC UL 489, CSA 22.2 No. 5 s Auxiliary contacts The auxiliary contacts will signal whether the breaker is in the ON or OFF position. Description Catalog number For field mounting: right side S2C-H6RU Bell alarm The bell alarm includes a set of contacts that will only signal when the breaker has tripped. Typically the contacts would be connected to an alarm or bell to signal the operator that an overcurrent trip has occurred. The bell alarm also includes a test button for testing the alarm contacts without opening the breaker. S2C-H6RU Description Catalog number For field mounting: right side S2C-S6RU Rotary operating mechanism Allows “through the door” operation. Description Catalog number Handle mechanism S2C-DH Shunt trip For remote tripping of breaker, a shunt trip device can be added to the MCB. The solenoid device opens the breaker after control voltage is applied. Description S2C-S6RU Catalog number For field mounting: right side 12…60 VAC/DC S2C-A1U For field mounting: right side 110…415 VAC S2C-A2U 110…250 VDC NOTE: For shafts and handles, refer to parts in the MCCB section. Possible mounting arrangements of MCB accessories 15 Legend S2C-DH Auxiliary contact +ST+H+H+H) +ST+S/H+S/H (H)+S/H (H) H Bell alarm/Auxiliary contact S/H Bell alarm/Auxiliary contact used as auxiliary contact S/H (H) Shunt trip ST NOTE: Right hand mount accessories cannot be used in conjunction with S2C-DH, Rotary operating mechanism. S2C-A1U Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com re s tu ker a i in ea M it br 0 cu S20 cir Accessories S200U, S200UP, S200UDC & SU200PR UL 489, CSA 22.2 No. 5 Connection drawings Bell alarm S2C-S6RU Auxiliary contact S2C-H6RU In ON and OFF position after hand operation Auxiliary contact in ON position Shunt trip S2C-A...U Shunt trip in OFF position S2C-A1U S2C-A2U In OFF position after tripping Auxiliary contact in OFF position Mounting Addition of a S2C-H6RU auxiliary contact Addition of a S2C-S6RU bell alarm contact 15 Addition of a S2C-A..U shunt trip S200U-UP S2C-A....U Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com Accessories SU200PR UL 489, CSA 22.2 No. 5 cir Min cu ia it b tur S2 rea e 00 ke r s SU200PR Accessory overview H Auxiliary contact S2C-H6RU S Signal contact S2C-S6RU ST Shunt trip S2C-A...U SU200PR Instructions for use 15 Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com re s tu ker a i in ea M it br 0 cu S20 cir Accessories S200U, S200UP & S200UDC UL 489, CSA 22.2 No. 5 UL approved busbars UL file # E250145 UL 489 busbar cannot be cut. PS2/6/16 BP For use on: Amp rating Number of poles Phases Busbar length (mm) Catalog number S200U S200UP S201UDC 80 6 12 18 1 1 1 103.2 208.8 314.4 PS 1/6/16BP PS 1/12/16BP PS 1/18/16BP S200U S200UP S201UDC 80 6 12 18 2 2 2 103.2 208.8 314.4 PS 2/6/16BP PS 2/12/16BP PS 2/18/16BP S200U S200UP S201UDC 80 6 12 18 3 3 3 103.2 208.8 314.4 PS 3/6/16BP PS 3/12/16BP PS 3/18/16BP 1 Phase 2 Phase Busbar tooth covers for BS...BP (UL 489) Description Covers three unused poles of busbar Catalog number BSK-BP 3 Phase BSK-BP Feeder terminals for PS...BP (UL 489) Description Catalog number Terminal, insulated with pin contact AST35/15BP Feeder Terminal, single-pole terminal, can be mounted side by side, feed on the pin of the busbar SZ-ESK BP AST35/15BP SZ-ESPBP 15 Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com cir Min cu ia it b tur S2 rea e 00 ke r Technical data S200U, S200UP, SU200PR & S200UDC UL 489, CSA 22.2 No. 5 Technical data S200U S200UP Specifications: UL File-Number: No. of poles: Tripping characteristics: Rated current: UL 489, C 22.2 No. 5, IEC 60947-2 E 212323, UL, Current limiting series ratings 1, 2, 3 & 4 K, Z 0.2 (K) 0.5 (Z) ... 63 A 0.2 (K) 0.5 (Z) ... 25 A Rated voltage: Single pole: 240VAC Multi pole: 240VAC Short circuit capacity: Frequency: Degree of protection: Mounting position: Fixing: Clamps only for Cu: Service life, mech. and at rated load: Tightening torque: Single pole: 277VAC Multi pole: 480Y/277VAC s SU200PR S200UDC K 0.2 ... 63A Single pole: 277VAC (<=35A); 240VAC (>35A) Multi pole: 480Y/277VAC (<=35A); 240VAC (>35A) IP20, IP40 in enclosure w/cover Any 14 kA 50/60 Hz IP 20 Vertical and horizontal 35 mm DIN rail 18-4 AWG (0.75 … 25 mm2) 20,000 operations 6000 operations (AC) 1 cycle (1s-ON, 9S-OFF) 20,000 operations – 25 °C … + 55 °C/– 13 °F … + 131 °F Shock resistance: 1P: 60 V DC 2P:125 V DC 1 10 kA 50/60 Hz IP 20 Vertical and horizontal 35 mm DIN rail 18-4 AWG (0.75 … 25 mm2) 25 in. lbs (2.8 Nm) Ambient temperature: UL 489, VDE 0660 E212323, UL 1, 2 K, Z 1 - 63 A 30 g at least 2 impacts shock, duration 13 ms 25 g, 2 shocks - 13ms 25 in. lbs (2.8 Nm) – 25 °C … + 55 °C/– 13 °F … + 131 °F 30 g at least 2 impacts shock, duration 13 ms Auxiliary contact S2C-H6RU and S2C-S6RU Rated current: Rated voltage AC / DC: Contact: Connection capacity mm2 Tightening torque: Shock resistance acc. to DIN IEC 68-2-6: Mechanical service life: Shunt trip Rated voltage Max. release duration Min. release voltage Consumption on release Coil resistance Terminals Tightening torque 10 24 1 pole double throw 18 – 14 AWG (0.75…2.5 mm2) 11 in.Ibs (1.2 Nm) 5 g, 20 frequency cycles 5...150...5 Hz at 24 VAC/DC, 5 mA auto-reclosing < 10 ms 10,000 operations Type AC DC AC DC AC DC V V ms V V VA VA Ω AWG/mm2 in.Ibs/Nm S2C-A1U S2C-A2U 12 ... 60 12 ... 60 < 10 7 10 40 ... 200 40 ... 200 3.7 18…6 / 0.75 – 16 18 / 2 110 ... 415 110 ... 250 < 10 55 80 55 ... 210 55 ... 110 225 18…6 / 0.75 – 16 18 / 2 1 Poles connected in series. Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com 15 re s tu ker a i in ea M it br 0 cu S20 cir Technical data S200U, S200UP, SU200PR & S200UDC UL 489, CSA 22.2 No. 5 Internal resistance and power loss Internal resistance per pole in mz, power loss per pole in W. Type Rated current S200U S200UP Device series K Device series Z Type Rated current Device series K Device series Z A mz W mz W A mz W mz W 0.2 0.3 0.5 42500 20000 6340 1.7 1.8 1.6 – – 10100 – – 2.5 1 1.6 1400 625 1.4 1.6 2270 1100 2.3 2.8 0.75 1 1.6 2500 1400 625 1.4 1.4 1.6 – 2270 1100 – 2.3 2.8 2 3 4 460 211 153 1.8 1.9 2.6 619 211 163 2.5 1.9 2.5 2 3 4 460 211 163 1.8 1.9 2.6 619 211 163 2.5 1.9 2.6 6 8 10 67 45 19 2.4 2.9 1.9 104 55 21 3,7 3.5 2.1 6 8 10 67 45 19 2.4 2.9 1.9 104 55 21 3.7 3.5 2.1 13 16 20 – 8.2 7.3 – 2.1 2.0 – 10.9 7.3 – 2.8 2.9 13 16 20 – 8.2 7.3 – 2.1 2.9 – 10.9 7.3 – 2.8 2.9 25 32 40 5.6 4.1 4.0 3.5 4.2 6.4 5.6 4.1 4.0 3.5 4.2 6.4 25 32 40 5.6 4.1 4.0 3.5 4.2 6.4 5.6 4.1 4.0 3.5 4.2 6.4 50 63 1.2 1.3 3.0 5.2 1.8 1.3 4.4 5.2 50 63 1.2 1.3 3.0 5.2 1.8 1.3 4.4 5.2 S200UDC SU200PR 15 Rated current Internal resistance per pole 1) Power loss per pole 1) A mΩ W 0.2 25300 1.01 0.3 13700 1.23 0.5 4740 1.19 0.75 2067 1.16 1 1270 1.27 1.5 610 1.56 2 442 1.77 3 140 1.26 4 109 1.75 5 50 1.26 6 54 1.94 8 22 1.41 10 18.2 1.82 13 14.8 2.50 15 8.1 1.83 16 11.1 2.83 20 8.5 3.40 25 5.5 3.43 30 3.8 3.39 32 4.6 4.70 35 3.9 4.76 40 2.8 4.40 50 1.7 4.25 60 1.7 6.18 63 1.9 7.56 Internal resistances and power loss are subject to application-specific and environment specific conditions and are therefore to be considered as typical values. 4) Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com cir Min cu ia it b tur S2 rea e 00 ke r Technical data S200U, S200UP, SU200PR & S200UDC UL 489, CSA 22.2 No. 5 Tripping characteristic K (68 °F) s Tripping characteristic Z (68 °F) Breaker calibration temperature 68°F See chart below for temperature DeRating Breaker calibration temperature 68°F See chart below for temperature DeRating Temperature derating Max. operating current values depending on the ambient temperature for a circuit-breaker of characteristics type K and Z K and Z In (A) 0.5 1.0 1.6 2.0 3.0 4.0 6.0 8.0 10.0 13.0 16.0 20.0 25.0 32.0 40.0 50.0 63.0 Ambient temperature T (°C/°F) – 40/– 40 – 30/– 22 – 20/– 4 0.66 1.32 2.12 2.65 4.0 5.3 7.9 10.8 13.2 17.2 21.2 26.5 33.1 42.3 52.9 66.1 83.3 0.64 1.27 2.04 2.55 3.8 5.1 7.6 10.2 12.7 16.6 20.4 25.5 31.9 40.8 51.0 63.7 80.3 0.61 1.22 1.96 2.45 3.7 4.9 7.3 9.8 12.2 15.9 19.6 24.5 30.6 39.2 49.0 61.2 77.2 – 10/14 0/32 10/50 20/68 30/86 40/104 50/122 60/140 70/158 0.59 1.17 1.88 2.35 3.5 4.7 7.0 9.4 11.7 15.2 18.8 23.5 29.3 37.5 46.9 58.6 73.9 0.56 1.12 1.79 2.24 3.4 4.5 6.7 8.9 11.2 14.5 17.9 22.4 28.0 35.8 44.7 55.9 70.4 0.53 1.06 1.70 2.12 3.2 4.2 6.4 8.5 10.6 13.8 17.0 21.2 26.5 33.9 42.4 53.0 66.8 0.50 1.00 1.60 2.00 3.0 4.0 6.0 8.0 10.0 13.0 16.0 20.0 25.0 32.0 40.0 50.0 63.0 0.47 0.94 1.50 1.87 2.8 3.7 5.6 7.5 9.4 12.2 15.0 18.7 23.4 29.9 37.4 46.8 58.9 0.43 0.87 1.39 1.73 2.6 3.5 5.2 6.9 8.7 11.3 13.9 17.3 21.7 27.7 34.6 43.3 54.6 0.40 0.79 1.26 1.58 2.4 3.2 4.7 6.3 7.9 10.3 12.6 15.8 19.8 25.3 31.6 39.5 49.8 0.35 0.71 1.13 1.41 2.1 2.8 4.2 5.7 7.1 9.2 11.3 14.1 17.7 22.6 28.3 35.4 44.5 0.31 0.61 0.98 1.22 1.8 2.4 3.7 4.9 6.1 8.0 9.8 12.2 15.3 19.6 24.5 30.6 38.6 Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com 15 re s tu ker a i in ea M it br 0 cu S20 cir Approximate dimensions S200U, S200UP, S200UDC & SU200PR UL 489, CSA 22.2 No. 5 Approximate dimensions in mm S200UDC S200U SU200PR S200UP S2C-H6RU, S2C-S6RU S2C-A..U 15 Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com Supplementary protective devices S200 UL 1077 Series S200 Supplementary protective UL 1077 Series Description The S200 UL 1077 Series miniature supplementary protector offers a compact solution for protection requirements. The S200 devices are DIN rail mounted. The S200 is available with application-specific trip characteristics to provide maximum circuit protection. The supplementary protectors offer thermalmagnetic trip protection according to B, C, D, K and Z characteristics. For the worldwide market, the breakers carry UL, CSA, IEC, CE and many other agency approvals and certifications. S200 Amperage Voltage Poles Trip characteristics 0.5 – 63 A s Features • Energy limiting • Fast breaking time (2.3 – 2.5 ms) • Bus connection system • Wide range of accessories • Available with variable depth handle mechanism • CE certified and marked • DIN rail mounting • Finger safe terminals • Multi-function terminals • Suitable for reverse feed • UL1077 Recognized supplemental protective device. UL file # E76126 S200P 0.2 – 63 A cir Min cu ia it b tur S2 rea e devices 00 ker S200PR 0.2 – 63A S280UC 0.2 – 63 A 480Y/277 VAC 480Y/277 VAC 240 VAC 250/500 VDC 1, 2, 3, 4 1, 2, 3, 4 1, 2, 3, 4 1, 2, 3, 4 B, C, D, K B, C, D, K, Z K K, Z 10kA: UL1077 10kA: CSA 22.2 No.235 Up to 6kA : IEC 60947-2 10kA : UL 1077 6 kA : CSA 22.2 No. 235 6 kA : IEC 60898 6 kA : UL 1077 6 kA : CSA 22.2 No. 235 Up to 25kA : IEC 60947-2 10kA : UL 1077 Auxiliary contacts Yes Yes Yes Yes Bell alarm Yes Yes Yes Yes Shunt trip Undervoltage release Bus bar Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes No Yes Interrupting ratings Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com 15 re s tu ker a i in ea M it br 0 cu S20 cir B S200-B, 480Y/277 VAC Supplemental protectors UL 1077, CSA 22.2, No. 235 No. of poles 1 S201-B S202-B 1 + NA 2 Rated current 6 10 13 16 20 25 32 40 50 63 6 10 13 16 20 25 32 40 50 63 6 10 13 16 20 25 32 40 50 63 Catalog number S201-B6 S201-B10 S201-B13 S201-B16 S201-B20 S201-B25 S201-B32 S201-B40 S201-B50 S201-B63 S201-B6NA S201-B10NA S201-B13NA S201-B16NA S201-B20NA S201-B25NA S201-B32NA S201-B40NA S201-B50NA S201-B63NA S202-B6 S202-B10 S202-B13 S202-B16 S202-B20 S202-B25 S202-B32 S202-B40 S202-B50 S202-B63 No. of poles 3 3 + NA 4 Rated current 6 10 13 16 20 25 32 40 50 63 6 10 13 16 20 25 32 40 50 63 6 10 13 16 20 25 32 40 50 63 Catalog number S203-B6 S203-B10 S203-B13 S203-B16 S203-B20 S203-B25 S203-B32 S203-B40 S203-B50 S203-B63 S203-B6NA S203-B10NA S203-B13NA S203-B16NA S203-B20NA S203-B25NA S203-B32NA S203-B40NA S203-B50NA S203-B63NA S204-B6 S204-B10 S204-B13 S204-B16 S204-B20 S204-B25 S204-B32 S204-B40 S204-B50 S204-B63 Tripping characteristic B UL 1077 480Y/277VAC 6 kA S203-B Resistive loads • B Curve • Designed for use in cable protection applications • Example: control circuits, lighting Accessories & technical data Accessories – See page 15.31 - 15.34 Technical data – See page 15.35 - 15.36 15 S204-B S201-BNA S203-BNA Note: Switching neutral is noted by “NA” in the catalog number. Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com cir Min cu ia it b tur S2 rea e 00 ke r S200-C, 480Y/277 VAC Supplemental protectors UL 1077, CSA 22.2, No. 235 C No. of poles 1 S201-C S202-C 1 + NA S203-C 2 S204-C Rated current 0.5 1 1.6 2 3 4 6 8 10 13 16 20 25 32 40 50 63 0.5 1 1.6 2 3 4 6 8 10 13 16 20 25 32 40 50 63 0.5 1 1.6 2 3 4 6 8 10 13 16 20 25 32 40 50 63 Catalog number S201-C0.5 S201-C1 S201-C1.6 S201-C2 S201-C3 S201-C4 S201-C6 S201-C8 S201-C10 S201-C13 S201-C16 S201-C20 S201-C25 S201-C32 S201-C40 S201-C50 S201-C63 S201-C0.5NA S201-C1NA S201-C1.6NA S201-C2NA S201-C3NA S201-C4NA S201-C6NA S201-C8NA S201-C10NA S201-C13NA S201-C16NA S201-C20NA S201-C25NA S201-C32NA S201-C40NA S201-C50NA S201-C63NA S202-C0.5 S202-C1 S202-C1.6 S202-C2 S202-C3 S202-C4 S202-C6 S202-C8 S202-C10 S202-C13 S202-C16 S202-C20 S202-C25 S202-C32 S202-C40 S202-C50 S202-C63 s No. of poles 3 3 + NA 4 Rated current 0.5 1 1.6 2 3 4 6 8 10 13 16 20 25 32 40 50 63 0.5 1 1.6 2 3 4 6 8 10 13 16 20 25 32 40 50 63 0.5 1 1.6 2 3 4 6 8 10 13 16 20 25 32 40 50 63 Catalog number S203-C0.5 S203-C1 S203-C1.6 S203-C2 S203-C3 S203-C4 S203-C6 S203-C8 S203-C10 S203-C13 S203-C16 S203-C20 S203-C25 S203-C32 S203-C40 S203-C50 S203-C63 S203-C0.5NA S203-C1NA S203-C1.6NA S203-C2NA S203-C3NA S203-C4NA S203-C6NA S203-C8NA S203-C10NA S203-C13NA S203-C16NA S203-C20NA S203-C25NA S203-C32NA S203-C40NA S203-C50NA S203-C63NA S204-C0.5 S204-C1 S204-C1.6 S204-C2 S204-C3 S204-C4 S204-C6 S204-C8 S204-C10 S204-C13 S204-C16 S204-C20 S204-C25 S204-C32 S204-C40 S204-C50 S204-C63 Tripping characteristic C UL 1077 480Y/277 VAC 6 kA Resistive loads • C Curve • Designed for use with medium magnetic start up currents • Example: lighting, control panels S201-CNA Accessories & technical data Accessories – See page 15.31 - 15.34 Technical data – See page 15.35 - 15.36 S203-CNA Note: Switching neutral is noted by “NA” in the catalog number. Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com 15 re s tu ker a i in ea M it br 0 cu S20 cir D S200-D, 480Y/277 VAC Supplemental protectors UL 1077, CSA 22.2, No. 235 No. of poles 1 S201-D S202-D 1 + NA S203-D 2 15 S204-D Rated current 0.5 1 1.6 2 3 4 6 8 10 13 16 20 25 32 40 50 63 0.5 1 1.6 2 3 4 6 8 10 13 16 20 25 32 40 50 63 0.5 1 1.6 2 3 4 6 8 10 13 16 20 25 32 40 50 63 Catalog number S201-D0.5 S201-D1 S201-D1.6 S201-D2 S201-D3 S201-D4 S201-D6 S201-D8 S201-D10 S201-D13 S201-D16 S201-D20 S201-D25 S201-D32 S201-D40 S201-D50 S201-D63 S201-D0.5NA S201-D1NA S201-D1.6NA S201-D2NA S201-D3NA S201-D4NA S201-D6NA S201-D8NA S201-D10NA S201-D13NA S201-D16NA S201-D20NA S201-D25NA S201-D32NA S201-D40NA S201-D50NA S201-D63NA S202-D0.5 S202-D1 S202-D1.6 S202-D2 S202-D3 S202-D4 S202-D6 S202-D8 S202-D10 S202-D13 S202-D16 S202-D20 S202-D25 S202-D32 S202-D40 S202-D50 S202-D63 No. of poles 3 3 + NA 4 Rated current 0.5 1 1.6 2 3 4 6 8 10 13 16 20 25 32 40 50 63 0.5 1 1.6 2 3 4 6 8 10 13 16 20 25 32 40 50 63 0.5 1 1.6 2 3 4 6 8 10 13 16 20 25 32 40 50 63 Catalog number S203-D0.5 S203-D1 S203-D1.6 S203-D2 S203-D3 S203-D4 S203-D6 S203-D8 S203-D10 S203-D13 S203-D16 S203-D20 S203-D25 S203-D32 S203-D40 S203-D50 S203-D63 S203-D0.5NA S203-D1NA S203-D1.6NA S203-D2NA S203-D3NA S203-D4NA S203-D6NA S203-D8NA S203-D10NA S203-D13NA S203-D16NA S203-D20NA S203-D25NA S203-D32NA S203-D40NA S203-D50NA S203-D63NA S204-D0.5 S204-D1 S204-D1.6 S204-D2 S204-D3 S204-D4 S204-D6 S204-D8 S204-D10 S204-D13 S204-D16 S204-D20 S204-D25 S204-D32 S204-D40 S204-D50 S204-D63 Tripping characteristic D UL 1077 480Y/277 VAC 6 kA Inductive loads • D Curve • Designed for allowing higher in-rush currents during system start up • Example: motors, transformers S201-DNA Accessories & technical data Accessories – See page 15.31 - 15.34 Technical data – See page 15.35 - 15.36 S203-DNA Note: Switching neutral is noted by “NA” in the catalog number. Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com cir Min cu ia it b tur S2 rea e 00 ke r S200-K, 480Y/277 VAC Supplemental protectors UL 1077, CSA 22.2, No. 235 K No. of poles 1 S201-K S202-K 1 + NA S203-K 2 S204-K Rated current 0.5 1 1.6 2 3 4 5 6 8 10 13 15 16 20 25 32 40 50 60 63 0.5 1 1.6 2 3 4 6 8 10 13 16 20 25 32 40 50 63 0.5 1 1.6 2 3 4 5 6 8 10 13 15 16 20 25 32 40 50 60 63 Catalog number S201-K0.5 S201-K1 S201-K1.6 S201-K2 S201-K3 S201-K4 S201-K5 S201-K6 S201-K8 S201-K10 S201-K13 S201-K15 S201-K16 S201-K20 S201-K25 S201-K32 S201-K40 S201-K50 S201-K60 S201-K63 S201-K0.5NA S201-K1NA S201-K1.6NA S201-K2NA S201-K3NA S201-K4NA S201-K6NA S201-K8NA S201-K10NA S201-K13NA S201-K16NA S201-K20NA S201-K25NA S201-K32NA S201-K40NA S201-K50NA S201-K63NA S202-K0.5 S202-K1 S202-K1.6 S202-K2 S202-K3 S202-K4 S202-K5 S202-K6 S202-K8 S202-K10 S202-K13 S202-K15 S202-K16 S202-K20 S202-K25 S202-K32 S202-K40 S202-K50 S202-K60 S202-K63 s No. of poles 3 3 + NA 4 Rated current 0.5 1 1.6 2 3 4 5 6 8 10 13 15 16 20 25 32 40 50 60 63 0.5 1 1.6 2 3 4 6 8 10 13 16 20 25 32 40 50 63 0.5 1 1.6 2 3 4 5 6 8 10 13 15 16 20 25 32 40 50 60 63 Catalog number S203-K0.5 S203-K1 S203-K1.6 S203-K2 S203-K3 S203-K4 S203-K5 S203-K6 S203-K8 S203-K10 S203-K13 S203-K15 S203-K16 S203-K20 S203-K25 S203-K32 S203-K40 S203-K50 S203-K60 S203-K63 S203-K0.5NA S203-K1NA S203-K1.6NA S203-K2NA S203-K3NA S203-K4NA S203-K6NA S203-K8NA S203-K10NA S203-K13NA S203-K16NA S203-K20NA S203-K25NA S203-K32NA S203-K40NA S203-K50NA S203-K63NA S204-K0.5 S204-K1 S204-K1.6 S204-K2 S204-K3 S204-K4 S204-K5 S204-K6 S204-K8 S204-K10 S204-K13 S204-K15 S204-K16 S204-K20 S204-K25 S204-K32 S204-K40 S204-K50 S204-K60 S204-K63 Tripping characteristic K UL 1077 480Y/277 VAC 6 kA S201-KNA Inductive loads • K Curve • Designed for allowing higher in-rush currents during system start up • Example: motors, transformers Accessories & technical data Accessories – See page 15.31 - 15.34 Technical data – See page 15.35 - 15.36 S203-KNA Note: Switching neutral is noted by “NA” in the catalog number. Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com 15 re s tu ker a i in ea M it br 0 cu S20 cir Z S200-Z, 480Y/277 VAC Supplemental protectors UL 1077, CSA 22.2, No. 235 No. of poles Rated current 1 0.5 1 1.6 2 3 4 6 10 13 16 20 25 32 40 50 63 2 0.5 1 1.6 2 3 4 6 10 13 16 20 25 32 40 50 63 S201-Z0.5 S202-Z0.5 Catalog number S201-Z0.5 S201-Z1 S201-Z1.6 S201-Z2 S201-Z3 S201-Z4 S201-Z6 S201-Z10 S201-Z13 S201-Z16 S201-Z20 S201-Z25 S201-Z32 S201-Z40 S201-Z50 S201-Z63 S202-Z0.5 S202-Z1 S202-Z1.6 S202-Z2 S202-Z3 S202-Z4 S202-Z6 S202-Z10 S202-Z13 S202-Z16 S202-Z20 S202-Z25 S202-Z32 S202-Z40 S202-Z50 S202-Z63 No. of poles Rated current 3 0.5 1 1.6 2 3 4 6 10 13 16 20 25 32 40 50 63 4 0.5 1 1.6 2 3 4 6 10 13 16 20 25 32 40 50 63 Catalog number S203-Z0.5 S203-Z1 S203-Z1.6 S203-Z2 S203-Z3 S203-Z4 S203-Z6 S203-Z10 S203-Z13 S203-Z16 S203-Z20 S203-Z25 S203-Z32 S203-Z40 S203-Z50 S203-Z63 S204-Z0.5 S204-Z1 S204-Z1.6 S204-Z2 S204-Z3 S204-Z4 S204-Z6 S204-Z10 S204-Z13 S204-Z16 S204-Z20 S204-Z25 S204-Z32 S204-Z40 S204-Z50 S204-Z63 Tripping characteristic Z UL 1077 480Y/277VAC 6 kA S203-Z0.5 15 Resistive loads • Z Curve • Designed to provide maximum protection with a very low shirt circuit trip setting • Example: semiconductors Accessories & technical data Accessories – See page 15.31 - 15.34 Technical data – See page 15.35 - 15.36 S204-Z0.5 Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com cir Min cu ia it b tur S2 rea e 00 ke r S200P-B, 480Y/277 VAC Supplemental protectors UL 1077, CSA 22.2, No. 235 B No. of poles 1 S210P-B6 2 S210P-B6 Rated current 6 10 13 16 20 25 32 40 50 63 6 10 13 16 20 25 32 40 50 63 Catalog number S201P-B6 S201P-B10 S201P-B13 S201P-B16 S201P-B20 S201P-B25 S201P-B32 S201P-B40 S201P-B50 S201P-B63 S202P-B6 S202P-B10 S202P-B13 S202P-B16 S202P-B20 S202P-B25 S202P-B32 S202P-B40 S202P-B50 S202P-B63 s No. of poles 3 4 Rated current 6 10 13 16 20 25 32 40 50 63 6 10 13 16 20 25 32 40 50 63 Catalog number S203P-B6 S203P-B10 S203P-B13 S203P-B16 S203P-B20 S203P-B25 S203P-B32 S203P-B40 S203P-B50 S203P-B63 S204P-B6 S204P-B10 S204P-B13 S204P-B16 S204P-B20 S204P-B25 S204P-B32 S204P-B40 S204P-B50 S204P-B63 Tripping characteristic B UL 1077 480Y/277 VAC 10 kA Resistive loads • B Curve • Designed for use in cable protection applications • Example: Control circuits, lighting S210P-B6 Accessories & technical data Accessories – See page 15.31 - 15.34 Technical data – See page 15.35 - 15.36 15 S210P-B6 Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com re s tu ker a i in ea M it br 0 cu S20 cir C S200P-C, 480Y/277 VAC Supplemental protectors UL 1077, CSA 22.2, No. 235 No. of poles S210P-B6 1 S210P-B6 2 S210P-B6 Rated current 0.5 1 1.6 2 3 4 6 8 10 13 16 20 25 32 40 50 63 0.5 1 1.6 2 3 4 6 8 10 13 16 20 25 32 40 50 63 Catalog number S201P-C0.5 S201P-C1 S201P-C1.6 S201P-C2 S201P-C3 S201P-C4 S201P-C6 S201P-C8 S201P-C10 S201P-C13 S201P-C16 S201P-C10 S201P-C25 S201P-C32 S201P-C40 S201P-C50 S201P-C63 S202P-C0.5 S202P-C1 S202P-C1.6 S202P-C2 S202P-C3 S202P-C4 S202P-C6 S202P-C8 S202P-C10 S202P-C13 S202P-C16 S202P-C10 S202P-C25 S202P-C32 S202P-C40 S202P-C50 S202P-C63 No. of poles 3 Rated current 0.5 1 1.6 2 3 4 6 8 10 13 16 20 25 32 40 50 63 Catalog number S203P-C0.5 S203P-C1 S203P-C1.6 S203P-C2 S203P-C3 S203P-C4 S203P-C6 S203P-C8 S203P-C10 S203P-C13 S203P-C16 S203P-C10 S203P-C25 S203P-C32 S203P-C40 S203P-C50 S203P-C63 Tripping characteristic C 15 UL 1077 480Y/277 VAC 10 kA Resistive loads • C Curve • Designed for use with medium magnetic start up currents • Example: Lighting, control panels Accessories & technical data Accessories – See page 15.31 - 15.34 Technical data – See page 15.35 - 15.36 Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com cir Min cu ia it b tur S2 rea e 00 ke r S200P-D, 480Y/277 VAC Supplemental protectors UL 1077, CSA 22.2, No. 235 D No. of poles S201P-D0.5 1 S202P-D0.5 2 S203P-D0.5 Rated current 0.5 1 1.6 2 3 4 6 8 10 13 16 20 25 32 40 50 63 0.5 1 1.6 2 3 4 6 8 10 13 16 20 25 32 40 50 63 Catalog number S201P-D0.5 S201P-D1 S201P-D1.6 S201P-D2 S201P-D3 S201P-D4 S201P-D6 S201P-D8 S201P-D10 S201P-D13 S201P-D16 S201P-D10 S201P-D25 S201P-D32 S201P-D40 S201P-D50 S201P-D63 S202P-D0.5 S202P-D1 S202P-D1.6 S202P-D2 S202P-D3 S202P-D4 S202P-D6 S202P-D8 S202P-D10 S202P-D13 S202P-D16 S202P-D10 S202P-D25 S202P-D32 S202P-D40 S202P-D50 S202P-D63 s No. of poles Rated current 3 0.5 1 1.6 2 3 4 6 8 10 13 16 20 25 32 40 50 63 Catalog number S203P-D0.5 S203P-D1 S203P-D1.6 S203P-D2 S203P-D3 S203P-D4 S203P-D6 S203P-D8 S203P-D10 S203P-D13 S203P-D16 S203P-D10 S203P-D25 S203P-D32 S203P-D40 S203P-D50 S203P-D63 Tripping characteristic D UL 1077 480Y/277 VAC 10 kA Inductive loads • D Curve • Designed for allowing higher in-rush currents during system start up • Example: motors, transformers Accessories & technical data Accessories – See page 15.31 - 15.34 Technical data – See page 15.35 - 15.36 Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com 15 re s tu ker a i in ea M it br 0 cu S20 cir K S200P-K, 480Y/277 VAC Supplemental protectors UL 1077, CSA 22.2, No. 235 No. of poles 1 S201P-K 2 S202P-K Rated current 0.2 0.3 0.5 0.75 1 1.6 2 3 4 6 8 10 13 16 20 25 32 40 50 63 0.2 0.3 0.5 0.75 1 1.6 2 3 4 6 8 10 13 16 20 25 32 40 50 63 Catalog number S201P-K0.2 S201P-K0.3 S201P-K0.5 S201P-K0.75 S201P-K1 S201P-K1.6 S201P-K2 S201P-K3 S201P-K4 S201P-K6 S201P-K8 S201P-K10 S201P-K13 S201P-K16 S201P-K20 S201P-K25 S201P-K32 S201P-K40 S201P-K50 S201P-K63 S202P-K0.2 S202P-K0.3 S202P-K0.5 S202P-K0.75 S202P-K1 S202P-K1,6 S202P-K2 S202P-K3 S202P-K4 S202P-K6 S202P-K8 S202P-K10 S202P-K13 S202P-K16 S202P-K20 S202P-K25 S202P-K32 S202P-K40 S202P-K50 S202P-K63 No. of poles 3 Rated current 0.2 0.3 0.5 0.75 1 1,6 2 3 4 6 8 10 13 16 20 25 32 40 50 63 Catalog number S203P-K0.2 S203P-K0.3 S203P-K0.5 S203P-K0.75 S203P-K1 S203P-K1,6 S203P-K2 S203P-K3 S203P-K4 S203P-K6 S203P-K8 S203P-K10 S203P-K13 S203P-K16 S203P-K20 S203P-K25 S203P-K32 S203P-K40 S203P-K50 S203P-K63 Tripping characteristic K UL 1077 480Y/277 VAC 10 kA 15 Inductive loads • K Curve • Designed for allowing higher in-rush currents during system start up • Example: motors, transformers Accessories & technical data S203P-K Accessories – See page 15.31 - 15.34 Technical data – See page 15.35 - 15.36 Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com cir Min cu ia it b tur S2 rea e 00 ke r S200P-Z, 480Y/277 VAC Supplemental protectors UL 1077, CSA 22.2, No. 235 Z No. of poles 1 S201P-Z 2 Rated current 0.5 1 1.6 2 3 4 6 8 10 16 20 25 32 40 50 63 0.5 1 1.6 2 3 4 6 8 10 16 20 25 32 40 50 63 Catalog number S201P-Z0.5 S201P-Z1 S201P-Z1.6 S201P-Z2 S201P-Z3 S201P-Z4 S201P-Z6 S201P-Z8 S201P-Z10 S201P-Z16 S201P-Z20 S201P-Z25 S201P-Z32 S201P-Z40 S201P-Z50 S201P-Z63 S202P-Z0.5 S202P-Z1 S202P-Z1.6 S202P-Z2 S202P-Z3 S202P-Z4 S202P-Z6 S202P-Z8 S202P-Z10 S202P-Z16 S202P-Z20 S202P-Z25 S202P-Z32 S202P-Z40 S202P-Z50 S202P-Z63 s No. of poles Rated current 3 0.5 1 1.6 2 3 4 6 8 10 16 20 25 32 40 50 63 Catalog number S203P-Z0.5 S203P-Z1 S203P-Z1.6 S203P-Z2 S203P-Z3 S203P-Z4 S203P-Z6 S203P-Z8 S203P-Z10 S203P-Z16 S203P-Z20 S203P-Z25 S203P-Z32 S203P-Z40 S203P-Z50 S203P-Z63 Tripping characteristic Z S202P-Z UL 1077 480Y/277 VAC 10 kA Resistive loads • Z Curve • Designed to provide maximum protection with a very low short circuit trip setting • Example: semiconductors Accessories & technical data Accessories – See page 15.31 - 15.34 Technical data – See page 15.35 - 15.36 S203P-Z Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com 15 re s tu ker a i in ea M it br 0 cu S20 cir K S200PR-K, 240 VAC, Ring tongue Supplemental protectors UL1077, CSA 22.2 No. 235 No. of poles 1 S201PR-K0.2 S202PR-K0.2 2 15 S203PR-K0.2 Rated current Catalog number 0.2 0.3 0.5 0.75 1 1.6 2 3 4 5 6 8 10 13 15 16 20 25 30 32 35 40 50 60 63 0.2 0.3 0.5 0.75 1 1.6 2 3 4 5 6 8 10 13 15 16 20 25 30 32 35 40 50 60 63 S201PR-K0.2 S201PR-K0.3 S201PR-K0.5 S201PR-K0.75 S201PR-K1 S201PR-K1.6 S201PR-K2 S201PR-K3 S201PR-K4 S201PR-K5 S201PR-K6 S201PR-K8 S201PR-K10 S201PR-K13 S201PR-K15 S201PR-K16 S201PR-K20 S201PR-K25 S201PR-K30 S201PR-K32 S201PR-K35 S201PR-K40 S201PR-K50 S201PR-K60 S201PR-K63 S202PR-K0.2 S202PR-K0.3 S202PR-K0.5 S202PR-K0.75 S202PR-K1 S202PR-K1.6 S202PR-K2 S202PR-K3 S202PR-K4 S202PR-K5 S202PR-K6 S202PR-K8 S202PR-K10 S202PR-K13 S202PR-K15 S202PR-K16 S202PR-K20 S202PR-K25 S202PR-K30 S202PR-K32 S202PR-K35 S202PR-K40 S202PR-K50 S202PR-K60 S202PR-K63 No. of poles 3 4 Rated current 0.2 0.3 0.5 0.75 1 1.6 2 3 4 5 6 8 10 13 15 16 20 25 30 32 35 40 50 60 63 0.2 0.3 0.5 0.75 1 1.6 2 3 4 5 6 8 10 13 15 16 20 25 30 32 35 40 50 60 63 Catalog number S203PR-K0.2 S203PR-K0.3 S203PR-K0.5 S203PR-K0.75 S203PR-K1 S203PR-K1.6 S203PR-K2 S203PR-K3 S203PR-K4 S203PR-K5 S203PR-K6 S203PR-K8 S203PR-K10 S203PR-K13 S203PR-K15 S203PR-K16 S203PR-K20 S203PR-K25 S203PR-K30 S203PR-K32 S203PR-K35 S203PR-K40 S203PR-K50 S203PR-K60 S203PR-K63 S204PR-K0.2 S204PR-K0.3 S204PR-K0.5 S204PR-K0.75 S204PR-K1 S204PR-K1.6 S204PR-K2 S204PR-K3 S204PR-K4 S204PR-K5 S204PR-K6 S204PR-K8 S204PR-K10 S204PR-K13 S204PR-K15 S204PR-K16 S204PR-K20 S204PR-K25 S204PR-K30 S204PR-K32 S204PR-K35 S204PR-K40 S204PR-K50 S204PR-K60 S204PR-K63 Tripping characteristic K UL 1077 480Y/277 VAC 10 kA Inductive loads • K Curve • Designed for allowing higher in-rush currents during system start up • Example: motors, transformers Accessories & technical data Accessories – See page 15.31 - 15.34 Technical data – See page 15.35 - 15.36 S203PR-K0.2 Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com cir Min cu ia it b tur S2 rea e 00 ke r S280UC-K, 500 VDC Supplemental protectors UL 1077, CSA 22.2, No. 235 K No. of poles 1 S281UC-K 2 S282UC-K Rated current Catalog number 0,2 0,3 0,5 0,75 1 1,6 2 3 4 6 8 10 16 20 25 32 40 50 63 0,2 0,3 0,5 0,75 1 1,6 2 3 4 6 8 10 16 20 25 32 40 50 63 S281UC-K0.2 S281UC-K0.3 S281UC-K0.5 S281UC-K0.75 S281UC-K1 S281UC-K1.6 S281UC-K2 S281UC-K3 S281UC-K4 S281UC-K6 S281UC-K8 S281UC-K10 S281UC-K16 S281UC-K20 S281UC-K25 S281UC-K32 S281UC-K40 S281UC-K50 S281UC-K63 S282UC-K0.2 S282UC-K0.3 S282UC-K0.5 S282UC-K0.75 S282UC-K1 S282UC-K1.6 S282UC-K2 S282UC-K3 S282UC-K4 S282UC-K6 S282UC-K8 S282UC-K10 S282UC-K16 S282UC-K20 S282UC-K25 S282UC-K32 S282UC-K40 S282UC-K50 S282UC-K63 s No. of poles Rated current 3 0.2 0.3 0.5 0.75 1 1.6 2 3 4 6 8 10 16 20 25 32 40 50 63 Catalog number S283UC-K0.2 S283UC-K0.3 S283UC-K0.5 S283UC-K0.75 S283UC-K1 S283UC-K1.6 S283UC-K2 S283UC-K3 S283UC-K4 S283UC-K6 S283UC-K8 S283UC-K10 S283UC-K16 S283UC-K20 S283UC-K25 S283UC-K32 S283UC-K40 S283UC-K50 S283UC-K63 Tripping characteristic K UL 1077 250/500 VDC 10 kA Inductive loads • K Curve • Designed for allowing higher in-rush currents during system start up • Example: motors, transformer Accessories & technical data Accessories – See page 15.31 - 15.34 Technical data – See page 15.35 - 15.36 S283UC-K Direct current applications 500 VDC Two Pole S201DC S282UC 3+ The S280UC differs from standard miniature circuit breakers in that the UC versions include a permanent magnet which aids in the extinguishing of the arc during medium and high level faults. It is necessary to observe the correct polarity and current direction when connecting the UC breakers. Two examples of correct connection are shown. Termination points are marked on all UC type MCBs, points one (1) and four (4) are negative and points two (2) and three (3) are positive. 4LOAD Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com 15 re s tu ker a i in ea M it br 0 cu S20 cir S280UC-Z, 500 VDC Supplemental protectors UL 1077, CSA 22.2, No. 235 Z No. of poles 1 S281UC-Z 2 Rated current 0.5 1 1.6 2 3 4 6 8 10 16 20 25 32 40 50 63 0.5 1 1.6 2 3 4 6 8 10 16 20 25 32 40 50 63 Catalog number S281UC-Z0.5 S281UC-Z1 S281UC-Z1.6 S281UC-Z2 S281UC-Z3 S281UC-Z4 S281UC-Z6 S281UC-Z8 S281UC-Z10 S281UC-Z16 S281UC-Z20 S281UC-Z25 S281UC-Z32 S281UC-Z40 S281UC-Z50 S281UC-Z63 S282UC-Z0.5 S282UC-Z1 S282UC-Z1.6 S282UC-Z2 S282UC-Z3 S282UC-Z4 S282UC-Z6 S282UC-Z8 S282UC-Z10 S282UC-Z16 S282UC-Z20 S282UC-Z25 S282UC-Z32 S282UC-Z40 S282UC-Z50 S282UC-Z63 No. of poles Rated current 3 0.5 1 1.6 2 3 4 6 8 10 16 20 25 32 40 50 63 Catalog number S283UC-Z0.5 S283UC-Z1 S283UC-Z1.6 S283UC-Z2 S283UC-Z3 S283UC-Z4 S283UC-Z6 S283UC-Z8 S283UC-Z10 S283UC-Z16 S283UC-Z20 S283UC-Z25 S283UC-Z32 S283UC-Z40 S283UC-Z50 S283UC-Z63 Tripping characteristic Z UL 1077 250/500 VDC 10 kA S282UC-Z Resistive loads • Z Curve • Designed to provide maximum protection with a very low short circuit trip setting • Example: semiconductors 15 Accessories & technical data Accessories – See page 15.31 - 15.34 Technical data – See page 15.35 - 15.36 Direct current applications The S280UC differs from standard miniature circuit breakers in that the UC versions include a permanent magnet which aids in the extinguishing of the arc during medium and high level faults. It is necessary to observe the correct polarity and current direction when connecting the UC breakers. Two examples of correct connection are shown. S283UC-Z 500 VDC Two Pole S201DC Termination points are marked on all UC type MCBs, points one (1) and four (4) are negative and points two (2) and three (3) are positive. S282UC 3+ 4LOAD Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com cir Min cu ia it b tur S2 rea e 00 ke r Accessories S200, S200P & S200PR UL 1077, CSA 22.2, No. 235 s Auxiliary contacts The auxiliary contacts will signal whether the breaker is in the ON or OFF position. Description For field mounting: right side Catalog number S2C-H6R Bell alarm - signal contact The bell alarm includes a set of contacts that will only signal when the breaker has tripped. Typically the contacts would be connected to an alarm or bell to signal the operator that an overcurrent trip has occurred. The bell alarm also includes a test button for testing the alarm contacts without opening the breaker. Description S2C-H6R For field mounting: right side Catalog number S2C-S/H6R 1 Shunt trip For remote tripping of breaker, a shunt trip device can be added to the MCB. The solenoid device opens the breaker after control voltage is applied. Description For field mounting: right side A1-12-60 VAC (12 – 60 VDC) A2-110-415 VAC (110 – 250 VDC) Catalog number S2C-A1 S2C-A2 Undervoltage release When control voltage drops below approximately 50 % of rated voltage, the UVR opens the breaker. The breaker can not be operated unless proper control voltage is first applied to the UVR coil. Description S2C-A For field mounting: right side 12 VDC 24 VAC/VDC 48 VAC/VDC 110 VAC/VDC 220 VAC/VDC 380 VAC Catalog number S2C-UA 12 S2C-UA 24 S2C-UA 48 S2C-UA 110 S2C-UA 230 S2C-UA 400 Possible mounting arrangements of MCB accessories 15 Legend S2C-UA Auxiliary contact +ST+H+H+H) +ST+S/H+S/H (H)+S/H (H) SA 1 H Bell alarm/Auxiliary contact S/H Bell alarm/Auxiliary contact used as auxiliary contact S/H (H) Shunt trip ST Undervoltage release UR Locking devices Description Catalog number Locking devices, 3 mm SA1 Padlock with 2 keys SA2 SA 2 1 Combination bell alarm/auxiliary contact. Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com re s tu ker a i in ea M it br 0 cu S20 cir Accessories S200PR UL 1077, CSA 22.2, No. 235 S200PR Accessory overview H Auxiliary contact S2C-H6R H-R Auxiliary contact S2C-H6-...R S/H Signal/Auxiliary contact S2C-S/H6R S/H (H) Signal/Auxiliary contact S2C-S/H6R used as auxiliary contact ST Shunt trip S2C-A... UR Undervoltage release S2C-UA S200PR Instructions for use 15 Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com cir Min cu ia it b tur S2 rea e 00 ke r Accessories S280UC UL 1077, CSA 22.2, No. 235 s Shunt trips Function: remote opening of the device when a voltage is applied Suitable for MCBs S 280 and S 280 UC series. Description S2-A1 I S2-A2 I C1 1 1 C1 C2 2 2 C2 110-415 VAC and 110-250 VDC shunt trip S2-A2 Signal contacts Function: indication of the position of the device’s contacts only after the automatic release of the MCBs and RCBOs due to an overload or a short-circuit Suitable for MCBs S 280 and S 280 UC series S 290 A1 S 290 A2 2 S2-A1 Auxiliary contacts Function: indication of the position of the device’s contacts Suitable for MCBs S 280 and S 280 UC series S2-A1 1 Catalog number 12-60 VAC/VDC shunt trip Description C1 C2 Catalog number Auxiliary contact 1 NO + 1 NC (1/2 module) S2-H11 Auxiliary contact 2 NO (1/2 module) S2-H20 Auxiliary contact 2 NC (1/2 module) S2-H02 Auxiliary contact 1 NO + 1 NC (1/2 module) with Faston connections S2-H11X Auxiliary contact 2 NO (1/2 module) with Faston connections S2-H20X S9-T24, S9-T130, S9-T415 S5 AL Auxiliary contact 2 NC (1/2 module) with Faston connections S2-H02X C1 C1 C2 1 2 1 C2 Auxiliary contact 2 NO + 1 NC (1/2 module) S2-H21 Auxiliary contact 1 NO + 2 NC (1/2 module) S2-H12 Auxiliary contact 3 NO (1/2 module) 2 S2-H30 InstallationAuxiliary only on leftcontact 3 NC (1/2 module) S2-H03 Signal contact (1/2 module) S2-S Signal contact + Auxiliary contact (1/2 module) S2-S/H Undervoltage release Function: protection of the load in the event of a voltage drop (between 70% and 35% of its rated value); positive safety (device’s tripping when the voltage is disconnected) emergency stop by means of a button. Suitable for MCBs S 280 and S 280 UC series. Description S2-UA12 S2-UA12 Undervoltage release 24V AC/DC (1 module) S2-UA24 Undervoltage release 48V AC/DC (1 module) S2-UA48 Undervoltage release 110V AC/DC (1 module) S2-UA110 Undervoltage release 220V AC/DC (1 module) S2-UA220 Undervoltage release 380V AC (1 module) S2-UA380 S2-H11 S2-h11 X S2-H20 S2-H02 S2-H21 S2-H20 X S2-H02 X S2-H12 S2-H30 S2-H03 13 21 1 13 23 1 11 21 1 11 23 33 1 11 21 33 1 13 23 33 1 11 21 31 1 14 22 2 14 24 2 12 22 2 12 24 34 2 12 22 34 2 14 24 34 2 12 22 32 2 S2-S 95 15 Catalog number Undervoltage release 12V DC (1 module) 1 95 Automatic ManualManual Automatic openingopening openingopening 1 95 1 95 1 95 1 95 1 96 98 2 96 98 296 98 2 96 98 296 98 2 96 98 2 S2-S/H 95 11 95 1 11 Automatic Automatic Manual Manual openingopening openingopening 95 1 11 95 1 11 95 1 11 95 1 11 1 96 98 12 96 14 982 12 1496298 12 96 14 98 2 12 1496298 12 96 14 98 2 12 14 2 Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com re s tu ker a i in ea M it br 0 cu S20 cir Accessories S280UC UL 1077, CSA 22.2, No. 235 Hand operated neutral The hand operated neutral has to be mounted to the left side of the MCB and be snapped on the DIN rail. It is used for measuring duties where the neutral conductor must be in the open position. Due to the special design of the handle - when switching ON the MCB – the neutral will make before the MCB is closed. The S2C - Nt is not to switch with a tool (screw driver). Description Hand operated neutral Catalog number S2-NT 15 Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com Schemes for combination and technical features Auxiliary elements for MCBs S 280 series cir Min cu ia it b tur S2 rea e 00 ke r s Combination between auxiliary elements and S 280 H S 280 S/H ST UR S UR H ST S H S UR ST Auxiliary contact Signal contact Undervoltare release Shunt trip S S/H Technical characteristics of auxiliary and signal contacts Type S2-H11 I S2-H11 X S2-H20 I S2-H20 X Description 1NO+1NC 2NO S2-H02 I S2-H02 X S2-H21 S2-H12 S2-H30 2NC 2NO+1NC 1NO+2NC 3NO S2-H03 3NC Alternating Ue [V] ••••••••••••••••••••••••••••••• 240 415 current Ie [A] ••••••••••••••••••••••••••••••• 6 2 Direct Ue [V] •••••••••••••••••••••••• 24 60 110 250 current Ie [A] •••••••••••••••••••••••• 4 2 1.5 1 Min.operating voltage [V] 12 a.c.-12 d.c. Min. operating current [mA] 12 up to 2x1.5 Terminals [mm2] Dielectric strength [kV] 3 Resistance to short-circuit at 240 V a.c. [A] 1000 (protected with S 2 breaker characteristic K - 6 A) Impulse voltage withstand capacity [kV] 4 Tightening torque [Nm] 0.7 Dimensions (WxDxH) [mm] 8.75x68x90 NB: the auxiliary contacts S2-H11 X, S2-H20 X, S2-H02 X differ from the contacts S2-H11, S2-H20, S2-H02 in that they do not have a terminal to tighten the cable which is replaced by a bayonet for the Faston connection. Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com 15 re s tu ker a i in ea M it br 0 cu S20 cir Technical features Auxiliary elements for MCBs S 280 series Technical characteristics of shunt trips Type S2-A1 S2-A2 Rated voltage [V] a.c. 12 - 60 110 - 415 d.c. 12 - 60 110 - 250 Max. release duration [ms] <10 <10 Min. release [V] voltage a.c. 7 55 d.c. 10 80 Consumption on release [VA] 12 V a.c. 35 12 V d.c. 30 24 V a.c. 140 24 V d.c. 100 48 V a.c. 600 48 V d.c. 330 110 V a.c. 40 110 V d.c. 40 220 V a.c. 180 220 V d.c. 170 Coil resistance [Ω] 3.7 225 Terminals [mm2] 25 25 Tightening torque [Nm] 2 2 Dimens.(WxDxH) [mm] 17.5x68x90 17.5x68x90 Technical characteristics of undervoltage releases Type S2-UA 12 S2-UA 24 S2-UA 48 S2-UA 110 S2-UA 220 S2-UA 380 Standards VDE0660 part I - IEC EN 60947.1 Rated [V] a.c. - 24 48 110 220-240 380 [V] d.c. 12 24 - 110 220-240 380 voltage Frequency [Hz] 50...60 Release trip [V] 0.35 Un≤V≤0.7 Un Terminals [mm2] 2 x 1.5 Consumption [mA] 10 15 Resistance to corrosion [°C/RH] const. climatic cond.: 23/83-40/93-55/20; var. climatic cond.: 25/95-40/93 Protection degree IP20 [Nm] 0.4 Tightening torque Dimensions (WxDxH) [mm] 17.5x68x90 S2-S 1 change over 240 415 6 2 250 110 60 24 0.5 1 1 4 S2-SH 2 change over 12 a.c.-12 d.c. 12 up to 2x1.5 3 1000 (protected with S 2 breaker characteristic K - 6 A) 4 0.7 8.75x68x90 Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com Accessories S200 & S200P UL 1077, CSA 22.2, No. 235 (suitable for cutting) cir Min cu ia it b tur S2 rea e 00 ke r s 1 Phase For use on: Amp rating Number of poles Phases Busbar length (mm) End cap catalog number S200 S200 P 63 80 60 60 1 1 986 986 PS-END0 PS-END0 For use on: Amp rating Number of poles Phases Busbar length (mm) End cap catalog number S200 S200 P 63 80 58 58 2 2 1035 1035 PS-ENDSP PS-ENDSP For use on: Amp rating Number of poles Phases Busbar length (mm) End cap catalog number S200 S200 P 63 80 60 60 3 3 1065 1065 For use on: Amp rating Number of poles Phases Busbar length (mm) S200 80 60 4 1056 Catalog number PS1/60SP PS1/60/16SP 1 Phase 2 Phase 2 Phase 3 Phase 4 Phase Catalog number PS2/58SP PS2/58/16SP 3 Phase PSB-ENDSP PSB-ENDSP Catalog number PS3/60SP PS3/60/16SP 4 Phase End cap catalog number PS-END1 Catalog number PS4/60/16SP NOTE All busbars may be center fed in order to increase ampacity up to 130 A. NOTE Busbars may be used on line or load side of MCBs Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com 15 re s tu ker a i in ea M it br 0 cu S20 cir Accessories S200 & S200P UL 1077, CSA 22.2, No. 235 1 Phase with 1 auxiliary For use on: Amp rating Number of poles Phases Busbar length (mm) End cap catalog number S200 & S200 P 63 80 38 38 1 1 1044 1044 – – Catalog number PS1/38H PS1/38/16H 1 Phase + Aux 2 Phase with 1 auxiliary For use on: Amp rating Number of poles Phases Busbar length (mm) End cap catalog number S200 & S200 P 80 48 2 1065 PS-ENDSP Catalog number PS2/48/16SP 2 Phase + Aux 3 Phase with 1 auxiliary For use on: Amp rating Number of poles Phases Busbar length (mm) End cap catalog number S200 & S200 P 80 39 3 980 PS-ENDSP Catalog number PS3/39/16SP 3 Phase + Aux 3 Phase + N, for use with 2 pole-MCBs on 3 phase/4W system 3 Phase + N 15 For use on: Amp rating Number of poles Phases Busbar length (mm) S200 & S200 P 80 58 4 1048 End cap catalog number Catalog number PS-END1SP PS4/58/16NSP NOTE NOTE All busbars may be center fed in order to increase ampacity up to 130 A. Busbars may be used on line or load side of MCBs Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com cir Min cu ia it b tur S2 rea e 00 ke r Accessories S200 & S200P UL 1077, CSA 22.2, No. 235 s Busbar tooth covers Description Covers five unused poles of busbar Catalog number BSK-SP BSK-SP Feeder terminals Description PS2/6/16 SP Catalog number Insulated with pin contact, 35mm sq. AST35/15SP For side by side mounting; feed on pin of busbar, 50mm sq. SZ-ESKSP AST35/15SP SZ-ESK SP 15 Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com re s tu ker a i in ea M it br 0 cu S20 cir Technical data S200, S200P, S200PR & S280UC UL 1077, CSA 22.2, No. 235 Technical data S200 Specifications: S200P UL 1077, CSA C 22.2, VDE 0660, 60898, 60947-2 UL File-Number: No. of poles: Tripping characteristics: Rated current: E 76126 UL CL 1, 2, 3 & 4 B, C, D, K & Z 0.5-63 A Rated voltage: E 76126 UL CL 1, 2, 3 & 4 B, C, D, K & Z 0.2-63 A Multi pole, 480Y/277 VAC Short circuit capacity: Frequency: Degree of protection: Mounting position: Fixing: Clamps only for Cu: S200 6kA; S200P 10 kA 50/60 Hz IP 20 Vertical, horizontal Service life, mech. and at rated load: 20,000 operations Tightening torque: Ambient temperature: 25 in. lbs (2.8 Nm) – 25°C … – 13°F / 70°C … 158°F 30 g at least 3 impacts, shock duration of 11 ms Shock resistance: S200PR UL1077, CSA 22.2 No. 235, IEC 60947-2 E 76126 UL CL 1, 2, 3 & 4 K 0.2-63 A 1 pole, 277 VAC, Multi pole, 480Y/277 VAC 10 kA 50/60 Hz IP 20, IP40 in enclosure w/cover Any 35mm DIN rail 18-4 AWG 6000 ops (AC), 1 cycle (1s -ON, 9s -OFF) S280UC UL1077, CSA 22.2, No. 235 – 1, 2, 3 K, Z 0.2-63 A 1 pole, 250 VDC, 230 VAC, Multipole, 500 VDC, 480 VAC 4.5 kA (10 kA, 60 VD 1P, 125 VDC, 2P 50/60 Hz IP 20 Any -25°C ... +55°C 6000 ops (AC/DC), 1 cycle (1s -ON, 9s -OFF) 17.5 in. lbs (2.5 Nm) -25°C ... +55°C 25g, 2 shocks, 13ms 30g, 3 shocks, 11ms Auxiliary contact S2C-H6R and Signal contact S2C-S6R for S200, S200P & S200PR Rated current: Rated voltage AC / DC: Contact: Connection capacity mm2 Tightening torque: Shock resistance acc. to DIN IEC 68-2-6: Mechanical service life: Shunt trip Rated voltage AC DC Max. release duration Min. release voltage 15 Consumption on release AC DC AD DC Coil resistance Terminals Tightening torque Undervoltage release Standards Rated voltage AC DC Frequency Release trip Terminals Consumption Resistance to corrosion Protection degree Tightening torque 10 24 1 pole, single throw 18 – 14 AWG (0.75…2.5) 11 in. Ibs (1.2 Nm) 5 g, 20 frequency cycles 5...150...5 Hz at 24 VAC/DC, 5 mA auto-reclosing < 10 ms 10,000 operations S2C-A1 S2C-A2 12 ... 60 V 12 ... 60 V < 10 ms 7V 10 V 40 ... 200 VA 40 ... 200 VA 3.7 Ω 18…6/0.75 – 16 AWG/mm2 18/2 in.Ibs/Nm 110 ... 415 V 110 ... 250 V < 10 ms 55 V 80 V 55 ... 210 VA 55 ... 110 VA 225 Ω 18…6/0.75 – 16 AWG/mm2 18/2 in.Ibs/Nm S2C-UA S2C-UA S2C-UA S2C-UA S2C-UA S2C-UA S2C-UA S2C-UA S2C-UA S2C-UA 12 DC 24 AC 24 DC 48 AC 48 DC 110 AC 110 DC 230 AC 230 DC 400 AC IEC/EN 60947-1 24 V 48 V 110 V 230 V 400 V 12 V 24 V 48 V 110 V 230 V 50 ... 60 Hz 0.35 UnOVO 0.7 Un V 2 x 16/2 x 1.5 AWG/mm2 0.2 VA 3.6 VA 2 VA 3.6 VA 2.1 VA 3.5 VA 2.2 VA 3.7 VA 2.3 VA 2.4 VA constant atmosphere: 23/83 – 40/93 – 55/20; variable atmosphere: 25/95 – 40/93 °C/RH IPXXB / IP2X 3.5/0.4 in.Ibs/Nm Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com cir Min cu ia it b tur S2 rea e 00 ke r Technical data S200, S200P & S200PR UL 1077, CSA 22.2, No. 235 s Internal resistance and power loss S200PR Internal resistance per pole in mz, power loss per pole in W Type Rated current Device series B, C, D1 Device series K Device series Z A mz W mz W mz W 0.5 1 1.6 5500 1440 630 1.4 1.4 1.6 6340 1550 695 1.6 1.6 1.8 10100 2270 1100 2.5 2.3 2.8 2 3 4 460 150 110 1.8 1.3 1.8 460 165 120 1.9 1.5 2.0 619 202 149 2.5 1.8 2.4 6 8 10 55 15 13.3 2.0 1.0 1.3 52 38 12.6 1.9 2.5 1.26 104 53.9 17.5 3.7 3.45 1.7 13 16 20 13.3 7.0 6.25 2.3 1.8 2.5 12.6 7.7 6.7 1.26 2.0 2.7 10.9 6.0 2.8 2.4 25 32 40 5.0 3.6 3.0 3.2 3.7 4.8 4.6 3.5 2.8 2.9 3.6 4.5 4.1 2.8 2.5 2.6 2.9 4.1 50 63 1.3 1.2 3.25 4.8 1.25 0.7 2.9 5.2 1.8 1.3 4.4 5.2 S200 & S200P Rated current Internal resistance per pole 4) Power loss per pole 4) mΩ 25300 13700 4740 2067 1270 610 442 140 109 50 54 22 18.2 14.8 8.1 11.1 8.5 5.5 3.8 4.6 3.9 2.8 1.7 1.7 1.9 W 1.01 1.23 1.19 1.16 1.27 1.56 1.77 1.26 1.75 1.26 1.94 1.41 1.82 2.50 1.83 2.83 3.40 3.43 3.39 4.70 4.76 4.40 4.25 6.18 7.56 A 0.2 0.3 0.5 0.75 1 1.5 2 3 4 5 6 8 10 13 15 16 20 25 30 32 35 40 50 60 63 1 Current intensities 0.5 - 4 apply exclusively to C-type trip characteristics Temperature derating Max operating current depending on the ambient temperature of a circuit breaker characteristics type B, C and D B, C, D, K, & Z Amps Ambient Temperatures T (Cº/Fº) -40/-40 0.67 1.33 2.13 2.67 4.0 -30/-22 0.65 1.29 2.07 2.58 3.9 -20/-4 0.62 1.25 2.00 2.49 3.7 -10/14 0.60 1.20 1.92 2.40 3.6 5.3 8.0 10.7 13.3 17.3 5.2 7.7 10.3 12.9 16.8 5.0 7.5 10.0 12.5 16.2 4.8 7.2 9.6 12.0 15.6 21.3 26.7 33.3 42.7 53.3 20.7 25.8 32.3 41.3 51.6 20.0 24.9 31.2 39.9 49.9 66.7 84.0 112.6 140.7 175.9 64.5 81.3 107.2 134.0 167.5 62.4 78.6 102.1 127.6 159.5 0/32 0.58 1.15 1.85 2.31 3.5 10/50 0.55 1.11 1.77 2.21 3.3 20/68 0.53 1.05 1.69 2.11 3.2 30/86 0.50 1.00 1.60 2.00 3.0 40/104 0.47 0.94 1.51 1.89 2.8 50/122 0.44 0.88 1.41 1.76 2.6 60/140 0.41 0.82 1.31 1.63 2.4 4.6 6.9 9.2 11.5 15.0 4.4 6.6 8.8 11.1 14.4 4.2 6.3 8.4 10.5 13.7 4.0 6.0 8.0 10.0 13.0 3.8 5.7 7.5 9.4 12.3 3.5 5.3 7.1 8.8 11.5 3.3 4.9 6.5 8.2 10.6 3.0 4.5 6.0 7.5 9.7 19.2 24.0 30.0 38.5 48.1 18.5 23.1 28.9 37.0 46.2 17.7 22.1 27.6 35.4 44.2 16.9 21.1 26.4 33.7 42.2 16.0 20.0 25.0 32.0 40.0 15.1 18.9 23.6 30.2 37.7 14.1 17.6 22.0 28.2 35.3 13.1 16.3 20.4 26.1 32.7 11.9 14.9 18.6 23.9 29.8 60.1 75.7 97.2 121.6 151.9 57.7 72.7 92.6 115.8 114.7 55.3 69.6 88.2 110.3 137.8 52.7 66.4 84.0 105.0 131.3 50.0 63.0 80.0 100.0 125.0 47.1 59.4 76.0 95.0 118.8 44.1 55.6 72.2 90.3 112.8 40.8 51.4 68.6 85.7 107.2 37.3 47.0 65.2 81.5 101.8 Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com 70/158 0.37 0.75 1.19 1.49 2.2 15 re s tu ker a i in ea M it br 0 cu S20 cir Technical data S200 & S200P UL 1077, CSA 22.2, No. 235 Tripping characteristic B Tripping characteristic C Tripping characteristic K Tripping characteristic Z Tripping characteristic D 15 Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com Approximate dimensions S200, S200P, S200PR UL 1077, CSA 22.2, No. 235 cir Min cu ia it b tur S2 rea e 00 ke r s S200, S200P S200PR SU200PR Instructions for use 15 Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com re s tu ker a i in ea M it br 0 cu S20 cir Approximate dimensions S280UC, S2C-H6R, S2C-A...U UL 1077, CSA 22.2, No. 235 S280UC S2C-H6R, S2C-A... S2C Addition of S2C-A...U LS 15 Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com Miniature circuit breaker Application guide ci Mi Ap rcui n iat pli t b ure cSa re t2io0 ak n0 g e rs uid e Introduction Breaker definition The circuit breaker plays an important role in providing over-current protection and a disconnect means in electrical networks. Recent advancements in circuit breaker technology has increased breaker performance and protection. A breaker is a device designed to isolate a circuit during an overcurrent event without the use of a fusible element. A breaker is a resettable protective device that protects against two types of overcurrent situations; Overload and Short Circuit. Overload A slow and small overcurrent situation that causes the ampacity and temperature of the circuit to gradually increase over time. This type of event is characterized by a slight increase in the load (ampacity) on the circuit and is interrupted by the thermal trip unit of the breaker. ABB current limiting breaker Tripping lever Electro-magnetic protection Thermal Example 10A Thermal protectionbimetal 15A Operating mechanism Breaker Upper terminal Light The light draws more than 10 amps for an extended period of time creating a thermal overload. Operator Short circuit A rapid and intense overcurrent situation that causes the ampacity of the circuit to increase. This type of event is characterized by a dramatic increase in the load (ampacity) on the circuit and is interrupted by the magnetic trip unit of the breaker. Arc chamber Magnetic Example 10A Breaker Fixed contact 10A Space for identification marker Moving contact Light The wire connected between the light and breaker is cut and shorted to ground creating a short circuit. Lower terminal Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com DIN rail holder 15 re s tu ker e a i in ea id M it br n0 gu cu t2io0 c ir plicSa Ap Circuit breaker construction Thermal / Magnetic trip units definition Magnetic trip units (short circuit protection) ABB Current Limiting Breakers use an electromechanical (Thermal / Magnetic) trip unit to open the breaker contacts during a overcurrent event. The thermal trip unit is temperature sensitive and the magnetic trip unit is current sensitive. Both units act independently and mechanically with the breaker’s trip mechanism to open the breaker’s contacts. The Magnetic trip unit protects against a short circuit. The magnetic trip unit is comprised of an electromagnet and an armature. Armature and Plunger Movable Contact Magnet Trip Unit Current Flow During Operation Magnetic Trip Unit Thermal Trip Unit All highlighted components are energized during operation Overload protection The thermal trip unit protects against a continuous overload. The thermal unit is comprised of a bimetal element located behind the circuit breaker trip bar and is part of the breaker’s current carrying path. When there is an overload, the increased current flow heats the bimetal causing it to bend. As the bimetal bends it pulls the trip bar which opens the breaker’s contacts. 15 Components of a magnetic trip unit When there is a short circuit, a high magnitude of current passes through the coils creating a magnetic field that attracts the movable armature towards the fixed armature. The hammer trip is pushed against the movable contact and the contacts are opened. The opening of the breakers contacts during a short circuit is complete in .5 milli-seconds. The time required for the bimetal to bend and trip the breaker varies inversely with the current. Because of this, the tripping time becomes quicker as current increases in magnitude. Overload protection is applicable to any installation, conductor, or component which can be subjected to low-magnitude but long-time overcurrents. Low-magnitude, long-time over-currents can be dangerous because they reduce the life of the electrical installation, conductor, and components and if left unchecked could result in fire. Trip Bar Operating Mechanism Thermal Trip Unit Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com Circuit breaker construction ci Mi Ap rcui n iat pli t b ure cSa re t2io0 ak n0 g e rs uid e Arc runners / Arc chutes Breaker curves The arc runner and arc chute limit and dissipate the arc energy during the interruption of an overload or short circuit event. Thermal Trip Unit (region one) The first sloping region of the breaker curve is a graphical representation of the tripping characteristics of the thermal trip unit. This portion of the curve is sloped due to the nature of the thermal trip unit. The trip unit bends to trip the breaker’s trip bar in conjunction with a rise in amperage (temperature) over time. As the current on the circuit increases, the temperature rises, the faster the thermal element will trip. During an overload or short circuit event, the contacts of the breaker separate and an electrical arc is formed between the contacts through air. The arc is moved into the arch chute by “running” the arc down the interior of the breaker along the arc runner. When the arc reaches the arc chute it is broken into small segmented arcs. The segmented arcs split the overall energy level into segments less than 25V. Each 25V segment does not have a high enough energy level to maintain an arc and all energy is naturally dissipated. Arc Runner Arc Chute Example using the curve below: If you had a 10A breaker and the circuit was producing 30 amps of current, the breaker would trip between 2 seconds and 1 minute. In this example you would find the circuit current on the bottom of the graph (Multiples of rated current). The first line is 10 amps (10 amp breaker x a multiple of one), the second line is 20 amps (10 amp breaker x multiple of 2), and the third line is 30 amps (10amp breaker x multiple of 3). Next you would trace the vertical 30A line up until it intersects the red portion of the breaker thermal curve. If you follow the horizontal lines, on both sides of the red curve, to the left you will see that the breaker can trip as fast as 2 seconds and no slower than 1 minute. Magnetic Trip Unit (region two) This region of the breaker curve is the instantaneous trip unit. ABB’s miniature circuit breaker’s instantaneous trip unit interrupts a short circuit in 2.3 to 2.5 milliseconds. Because of this the curve has no slope and is graphically represented as a vertical straight line. Example using the curve above: If you had a 10 amp breaker the magnetic trip element would interrupt a short circuit between 10 and 30 amps (10 amp breaker x multiple of 2 and 3) in 2.3 to 2.5 milliseconds. Breaker Contacts (region three) This region of the curve is the time required for the contacts of the breaker to begin to separate. The contacts will open in less than .5 milliseconds and is graphically represented by the bottom vertical portion of the curve. 15 Thermal Trip Unit (Region One) Magnetic Trip Unit (Region Two) Moving Contacts (Region Three) Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com re s tu ker e a i in ea id M it br n0 gu cu t2io0 c ir plicSa Ap Circuit breaker current limitation Current limiting definitions Current limiting breakers and electrical networks All ABB Miniature Circuit Breakers are UL tested and certified as current limiting protective devices. Current limiting circuit breakers provide a higher level of circuit protection than a typical zero point external breakers. Current Limitation When a short-circuit condition occurs, the “ideal” current limiting circuit breaker opens before the current waveform can reach its full potential magnitude which occurs at ¼ cycle (4.17ms). ABB’s current limiting breakers can interrupt a fault in about ½ cycle or 2.3ms to 2.5ms. UL AC 60Hz cycle UL defines an AC cycle as the potential energy of the wave form traveling from Zero-to-Positive amplitude, Positive-to-Zero amplitude, Zero-toNegative amplitude, Negative-to-Zero amplitude 60 times in one second. One cycle is completed every 16.6 milliseconds. UL breaker current limiting UL defines breaker current limitation as a breaker that interrupts and isolates a fault in less than 1/2 of an AC cycle. 1/2 a cycle is completed in 8.3 milliseconds. NEC240.2 current limiting A device that, when interrupting current in its current-limiting range, reduces the current flowing in the faulted circuit to a magnitude substantially less than that obtainable in the same circuit if the device were replaced with a solid conductor having comparable impedance. IEC 60947-2 current limiting circuit breaker A circuit breaker with sufficiently short trip time to prevent the short-circuit current from reaching the peak value which would otherwise be reached. ABB current limiting breakers ABB current limiting breakers can interrupt and isolate a fault in 1/8 of an AC cycle. The breaker fault interruption is completed in 2.3 to 2.5 milliseconds. Zero point extinguishing breakers 15 A typical zero point extinguishing breaker interrupts a fault and does not isolate the energy. The breaker allows an arc to be present between the open contacts until the AC wave form crosses zero. When the wave form crosses zero, the potential energy is zero and the arc (fault) naturally extinguishes. The arc could be present for up to 8.3 milliseconds. ABB’s current limiting breakers interrupt a short circuit in less than 1/8 cycle and limit the amount of current that can reach a circuit. Limiting the available current on the circuit provides additional protection against network, breaker, or bus damage and prevents the tripping of upstream breakers (selective coordination). IsqT The true destructive nature of a short circuit is measured by the time it is available combined with the peak value of the short circuit. The IsqT (Amps Squared over Time) value represents the amount of energy available on a network during a short circuit and is represented by the shaded area on the graph below. During a short circuit both magnetic forces and thermal energy combine to damage devices on the electrical network. The level of thermal energy and magnetic forces are directly proportional to the square of the current. The magnetic forces vary as a square of the peak current available and the thermal energy varies as a square of the RMS (root mean square) current available. ABB’s current limiting breakers will limit the let-through energy to a fraction (1/100th) of the value which is available from the network. By comparison, a Zero Crossing breaker would let-through approximately 100 times as much destructive energy as the current limiting circuit breaker [ (100,000A / 10,000A) squared – 100X]. ABB’s current limiting breakers limit the short circuit current to a relatively small magnitude in a extremely short time, which dramatically limits a short circuit’s destructive energy. Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com ci Mi Ap rcui n iat pli t b ure cSa re t2io0 ak n0 g e rs uid e Circuit breaker current limitation Current limiting and zero crossing breakers Zero crossing example During the initial stages of a short circuit a breaker’s contacts open to interrupt the circuit. After the contacts open an arc forms in the air between the contacts on both the current limiting and zero crossing breaker contacts. What distinguishes a current limiting breaker from a zero crossing breaker is what each breaker does after an arc is formed between the open contacts. The test report below details a 20A Zero Point Extinguishing breaker interrupting a 9kA fault in 9 milliseconds. The total "I Square T" value is 104.0kA. A current limiting breaker “runs” the arc down the breaker arc runner into an arc chute that extinguishes the arc. A zero crossing breaker does not attempt to extinguish the arc. The breaker is designed to withstand the energy of the arc long enough for the waveform to cross zero. When the wave form crosses zero the potential energy is zero and the arc naturally extinguishes itself. ABB’s current limiting breakers interrupt the arc energy in 2.3ms to 2.5ms (1/8 cycle) and a zero crossing breaker allows the arc to be present for up to 8.3ms (1/2 cycle). A zero crossing breaker will let through 100 times as much energy as an ABB current limiting breaker. 500 V 10 kA 400 8 300 6 200 4 100 2 U-BCP L2 100 /div I-L2 2 k/div Current limiting example The lab test report below details a 20A S200 series current limiting breaker interrupting a 28kA fault in 1.7 milliseconds. The total “I Square T” value is 32.0kA. -100 -2 -200 -4 -300 -6 -400 -8 -500 -10 Legend Voltage 500 V 10 kA 400 8 300 6 200 4 100 2 U-L2 100 /div Amps Time A Time B 0 0.9999 499.93 Sample/div 1.9997 2.9996 3.9994 4.9993 15 I-L2 2 k/div -100 -2 -200 -4 -300 -6 Legend Voltage -400 -8 -500 -10 5.9991 6.999 kSample Amps Time A Time B 0 0.9999 499.93 Sample/div 1.9997 2.9996 3.9994 4.9993 5.9991 6.999 kSample Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com re s tu ker e a i in ea id M it br n0 gu cu t2io0 c ir plicSa Ap Selective coordination and series ratings IEC 60497-1 selective coordination definition Example of no breaker coordination Coordination between the operating characteristics of two or more overcurrent protection devices, so that when an over-current within established limits occurs, the device designated to operate within those limits trips whereas the other do not trip. Selective breaker coordination is not achieved when there is an overload event at the branch breaker level (MCB1) and both the branch breaker and main breaker interrupt the circuit (open). When there is no breaker coordination several circuits lose power that should remain operational during and after the overload event. The chart below gives a graphical representation of a down stream branch breaker (B curve) and a main breaker (A curve) without coordination. There is no separation between the curves. The branch breaker will react to a fault and the main breaker will open and de-energize all circuits down stream. Main breaker CB1 CB2 CB3 CB4 Short circuit Example of breaker coordination When an over-current event occurs at the branch breaker level (CB1), and the event is within the operating characteristics of the breaker, then the branch breaker should interrupt the circuit (open) and the main breaker should remain closed and energized. The chart below gives a graphical representation of a down stream branch breaker (B curve) and a main breaker (A curve) with coordination. The separation between the curves allows the branch breaker to react to the fault and the main breaker remain closed and energized. 15 Problems in coordination occur when the branch breaker allows the "I Square T" value of the short circuit to rise to a level that is in the operating range of the up-stream main breaker. Proper breaker coordination is easier to achieve with the use of current limiting breakers at the branch level. Selective coordination and current limiting breakers Recent improvements in ABB circuit breaker technology has pushed the performance of breakers to the same level as fuses. The reaction time and tripping characteristics of current limiting breakers are now on par with fuses. This allows ABB to provide a high level of coordination between branch breakers and the main. A current limiting branch breaker will limit the “I Square T” value well below the level of the operating range of the upstream main breaker. ABB’s current limiting branch breakers can coordinate between the main breaker up to 35kA. Selective coordination and zero crossing breakers Zero crossing breakers do not limit the “I Square T” value. They wait for the wave form to cross zero and allow a high level of let-through energy to pass through the system. The “I Square T” value of a zero crossing breaker is high enough that the main breaker will likely trip during a short circuit. With zero crossing breakers it is extremely difficult to coordinate between branch and main breakers. A typical zero crossing breaker’s coordination level is below 10kA. There are a few manufactures that have achieved coordination between a branch zero crossing breaker and the main by slowing the performance (protection) of the main breaker. Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com Selective coordination and series ratings ci Mi Ap rcui n iat pli t b ure cSa re t2io0 ak n0 g e rs uid e Series ratings –vs- selective coordination Series ratings Selective coordination Series ratings are different from coordination ratings. Unlike coordination ratings where the branch opens and the main remains closed, a series rated combination is one where both the branch and main breakers open and work together to isolate the fault. Selective coordination is achieved when there is a short circuit on a branch circuit breaker, the branch breaker opens and isolates the fault, and the main breaker remains closed. The rating is usually a value above the “stand alone” interrupting rating of the branch breaker and the “stand alone” rating of the main breaker. Example: 65kA rated main breaker 10kA rated branch breaker Coordination between the two breakers up to 35kA There can be a short circuit on the branch breaker up to 35kA where the branch will open (CB1) and the main breaker will remain closed. Although the branch has a 10kA “stand alone” rating both the breakers work together to limit the available short circuit to allow the branch (CB1) to isolate the fault. Main breaker 65 kA CB1 10 kA CB2 10 kA CB3 10 kA The series rating combination of two breakers is equal to the “stand alone” interrupting value of the main breaker. This is a result of the main breaker let-through value being lower than the “stand alone” interrupting value of the branch breaker. During a short circuit the main breaker will limit the energy to a level that is below the “stand alone” value of the branch breaker. Example: 65kA rated main breaker 10kA rated branch breaker Series combination rating between the two breakers up to 65kA There can be a short circuit on the branch breaker up to 65kA where the branch will open and the main breaker will open. Although the branch breaker (CB1) has a 10kA “stand alone” rating the main breaker has a letthrough value below 10kA. If there is a fault up to 65kA on the network the main breaker will limit the energy to a value less than the rating of the branch breaker (CB1). Both breakers will trip (no coordination) but the network can safely withstand a fault of 65kA. CB4 10 kA 35 kA or 65 kA short circuit 15 Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com re s tu ker e a i in ea id M it br n0 gu cu t2io0 c ir plicSa Ap Miniature circuit breaker cutaway Tripping lever Electro-magnetic protection Upper terminal Thermal protection-bimetal Operating mechanism Operator Arc chamber 15 Fixed contact Space for identification marker Moving contact Lower terminal DIN rail clip Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com High performance circuit breakers S800 UL 489 Series S800 High performance circuit UL 489 Series cir Min cu ia it b tur S8 rea e breakers 00 ker Description Features The S800 high performance MCB offers a compact solution to circuit protection. The S800 devices are DIN rail mounted. The S800 is available with application-specific trip characteristics to provide maximum circuit protection. • Energy limiting • Fast breaking time (2.3 – 2.5 ms) • Wide range of accessories • DIN rail mounting • Finger safe terminals • Multi-function terminals • Ring tongue compatible • UL489 File # E312425 The breakers offer thermal-magnetic trip protection according to Z and K characteristics. For the worldwide market, the breakers carry CSA, IEC, CE and many other agency approvals. S800U Amperage Voltage Poles 10 – 100 A 240 VAC 1, 2, 3, 4 poles Trip characteristics Z, K Interrupting ratings 30kA: UL 489, single pole 50kA: UL 489, multi-pole Auxiliary contacts Yes Bell alarm Yes Shunt trip Yes Undervoltage release Yes Ring tongue Yes Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com s 15 e rs ur at ake i n e i M it br 0 u c S80 cir K S800U-K, 240 VAC Branch circuit protection UL 489 No. of poles 1 S801U-K 2 Rated current 10 15 20 25 30 40 50 60 70 80 90 100 10 15 20 25 30 40 50 60 70 80 90 100 S801U-K10 S801U-K15 S801U-K20 S801U-K25 S801U-K30 S801U-K40 S801U-K50 S801U-K60 S801U-K70 S801U-K80 S801U-K90 S801U-K100 S802U-K10 S802U-K15 S802U-K20 S802U-K25 S802U-K30 S802U-K40 S802U-K50 S802U-K60 S802U-K70 S802U-K80 S802U-K90 S802U-K100 Tripping characteristic K S802U-K No. of poles Catalog number UL 489 240 VAC 30 kA, single pole 50 kA, multi-pole Rated current 10 15 20 25 30 40 50 60 70 80 90 100 10 15 20 25 30 40 50 60 70 80 90 100 3 4 Catalog number S803U-K10 S803U-K15 S803U-K20 S803U-K25 S803U-K30 S803U-K40 S803U-K50 S803U-K60 S803U-K70 S803U-K80 S803U-K90 S803U-K100 S804U-K10 S804U-K15 S804U-K20 S804U-K25 S804U-K30 S804U-K40 S804U-K50 S804U-K60 S804U-K70 S804U-K80 S804U-K90 S804U-K100 10 000 1000 Resistive loads • K Curve • Designed for use in cable protection applications • Example: control circuits, lighting 100 Accessories & technical data 10 Accessories – See page 15.52 Technical data – See page 15.76 - 15.82 1 S803U-K seconds 15 0.1 0.01 1 2 3 10 20 30 multiple of rated current S804U-K Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com cir Min cu ia it b tur S8 rea e 00 ke r S800U-Z, 240 VAC Branch circuit protection UL 489 Z No. of poles 1 S801U-Z 2 Rated current 10 15 20 25 30 40 50 60 70 80 90 100 10 15 20 25 30 40 50 60 70 80 90 100 s No. of poles Catalog number S801U-Z10 S801U-Z15 S801U-Z20 S801U-Z25 S801U-Z30 S801U-Z40 S801U-Z50 S801U-Z60 S801U-Z70 S801U-Z80 S801U-Z90 S801U-Z100 S802U-Z10 S802U-Z15 S802U-Z20 S802U-Z25 S802U-Z30 S802U-Z40 S802U-Z50 S802U-Z60 S802U-Z70 S802U-Z80 S802U-Z90 S802U-Z100 3 4 Rated current Catalog number 10 15 20 25 30 40 50 60 70 80 90 100 10 15 20 25 30 40 50 60 70 80 90 100 S803U-Z10 S803U-Z15 S803U-Z20 S803U-Z25 S803U-Z30 S803U-Z40 S803U-Z50 S803U-Z60 S803U-Z70 S803U-Z80 S803U-Z90 S803U-Z100 S804U-Z10 S804U-Z15 S804U-Z20 S804U-Z25 S804U-Z30 S804U-Z40 S804U-Z50 S804U-Z60 S804U-Z70 S804U-Z80 S804U-Z90 S804U-Z100 S802U-Z Tripping characteristic Z 10 000 UL 489 240 VAC 30 kA, single pole 50 kA, multi-pole S803U-Z 1000 Resistive loads • Z Curve • Designed for use in cable protection applications • Example: control circuits, lighting 100 Accessories & technical data 15 10 Accessories – See page 15.52 Technical data – See page 15.76 - 15.82 seconds 1 S804U-Z 0.1 0.01 1 2 3 5 10 20 30 multiple of rated current Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com e rs ur at ake i n e i M it br 0 u c S80 cir S803W-SCL-SR UL Short circuit current limiter Self-resetting UL version short circuit current limiter, self resetting, 3 pole Item Catalog number 32A Self resetting current limiter 63A Self resetting current limiter 100A Self resetting current limiter S803W-SCL32-SR S803W-SCL63-SR S803W-SCL100-SR Technical data Rated voltage 600 VAC per UL508 Short circuit current rating according to UL508, CSA 22.2 480 VAC 50/60 Hz, 65 kA 600 VAC 50/60 Hz, 65 kA Approved combinations with motor starter Downstream devices Upstream devices S803W-SCL-SR S803W-SCL-SR Rated current Ie [A] Self resetting short-circuit limiter 32 63 100 MS/MO325 0.1– 2.5 ■ ■ ■ 4 ■ ■ ■ 6.3 ■ ■ ■ 9 ■ ■ ■ 12.5 ■ ■ ■ 16 ■ ■ ■ 20 ■ ■ 25 ■ ■ MS/MO132 0.1– 2.5 ■ ■ 4 ■ ■ 6.3 ■ ■ ■ 10 ■ ■ ■ 16 ■ ■ ■ 20 ■ ■ 25 ■ ■ 15 32 ■ ■ – Combinations with S500-K and S500-KM on request ■ Applies for all voltages according to the table below S803W-SCL-SR Rated ultimate short-circuit breaking capacity Short-circuit rating according to UL 508, CSA 22.2 (AC) 50/60 Hz 480 V [kA] 65 (AC) 50/60 Hz 600 V [kA] 65 (AC) 50/60 Hz 240/415 V [kA] 100 (AC) 50/60 Hz 254/440 V [kA] 100 (AC) 50/60 Hz 277/480 V [kA] 65 (AC) 50/60 Hz 289/500 V [kA] 65 (AC) 50/60 Hz 346/600 V [kA] 65 (AC) 50/60 Hz 400/690 V [kA] 50 Icu = Ics according to IEC 60947-2 Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com S803W-SCL-SR UL508 Short circuit current limiter Approximate dimensions cir Min cu ia it b tur S8 rea e 00 ke r s Minimum cable length between S803W-SCL-SR and downstream devices (Connection has to be short-circuit proofed acc. to IEC 61439-1) MS/M0325 MS/M0132 S800 S800-SCL-SR min. length X min. cross section 32 A 80 mm 6 mm2 x 63 A 80 mm 16 mm2 100/125 A 35 mm2 250 mm Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com 15 e rs ur at ake i n e i M it br 0 u c S80 cir S800W-RSU Remote sensing unit UL489 Remote switching unit Item Catalog number Remote switching unit S800W-RSU S800W-RSU S800-RSU cable including plug Item Catalog number 3 meter cable 0.5mm2 (AWG20) inclusing 10 pole Micro Fit 3.0 plug S800-RSU-CP Key Features • The remote Switching unit S800W-RSU has a brushless high precision DC motor to ensure fast remote control operation. S800W-RSU • Low power consumption • Short switching times • The S800W-RSU is mounted on any multipole S800 High Performance MCB • Installation and wiring can be field installable • The connection is done by a 10-pole Micro Fit 3.0 (not included in delivery) • The S800W-RSU can be operated by a standard pushbutton or drive by a PLC Switching times S800W-RSU mounted on MCB • OFF -> ON from signal to contact closing <<500ms • ON -> OFF from signal to contact opening <<250ms • TRIP -> OFF -> ON from signal to contact closing <<1500ms For differing requirements, please contact your local ABB partner Safety intelligence • Inputs are deactivated when detecting manual use • All outputs become active when spindle is rotated more than 360 degrees • S800W-RSU is locked for 5 minutes after three switching attempts leading to a trip • Manual switch off possible for 3 & 4 pole devices Technical specifications 15 S800-RSU-CP Operational voltage 24 VDC Current consumption Irms 2,5 Standby current IStandby < 50mA Switching time OFF-ON < 500 msec Switching time ON-OFF <250 mse Ambient operation temperature -25…+70°C Number of switching operations 10.000 Maximum cable lengths(AWG20/ 0.5mm2) 10m Degree of protection (mounted) IP2 Weight 300 gr Connection 10 pole Micro Fit 3.0 Approximate dimensions Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com High performance circuit breakers S800 IEC Series S800 High performance circuit IEC Series Description The S800 high performance MCB offers a compact solution to circuit protection. The S800 devices are IEC tested current limiting and DIN rail mounted. The S800 is available with application-specific trip characteristics to provide maximum circuit protection. The breakers offer thermal-magnetic trip protection according to B, C, D & K characteristics. Amperage Voltage Poles Trip characteristics Interrupting ratings Auxiliary contacts Bell alarm Shunt trip Undervoltage release Ring tongue cir Min cu ia it b tur S8 rea e breakers 00 ker s For the worldwide market, the breakers carry CSA, IEC, CE and many other agency approvals. Features • Current limiting • Fast breaking time (2.3 – 2.5 ms) • Wide range of accessories • DIN rail mounting • Finger safe terminals • Multi-function terminals • Ring tongue compatible S800S 10 – 125 A 690 VAC 1, 2, 3, 4 B, C, D, K 50 kA : IEC Yes Yes Yes Yes Yes Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com 15 e rs ur at ake i n e i M it br 0 u c S80 cir B S800S-B, 690 VAC IEC No. of poles 1 S801U-B 2 S802U-B Rated current 10 13 16 20 25 32 40 50 63 80 100 125 10 13 16 20 25 32 40 50 63 80 100 125 No. of poles Catalog number S801S-B10 S801S-B13 S801S-B16 S801S-B20 S801S-B25 S801S-B32 S801S-B40 S801S-B50 S801S-B63 S801S-B80 S801S-B100 S801S-B125 S802S-B10 S802S-B13 S802S-B16 S802S-B20 S802S-B25 S802S-B32 S802S-B40 S802S-B50 S802S-B63 S802S-B80 S802S-B100 S802S-B125 Tripping characteristic B Rated current Catalog number 10 13 16 20 25 32 40 50 63 80 100 125 10 13 16 20 25 32 40 50 63 80 100 125 3 4 S803S-B10 S803S-B13 S803S-B16 S803S-B20 S803S-B25 S803S-B32 S803S-B40 S803S-B50 S803S-B63 S803S-B80 S803S-B100 S803S-B125 S804S-B10 S804S-B13 S804S-B16 S804S-B20 S804S-B25 S804S-B32 S804S-B40 S804S-B50 S804S-B63 S804S-B80 S804S-B100 S804S-B125 10 000 IEC 690 VAC 50 kA 1000 Resistive loads • B Curve • Designed for use in cable protection applications • Example: control circuits, lighting 100 Accessories & technical data S803U-B Accessories – See page 15.52 Technical data – See page 15.76 - 15.82 10 15 seconds 1 S804U-B 0.1 0.01 1 2 3 5 10 20 30 multiple of rated current Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com cir Min cu ia it b tur S8 rea e 00 ke r S800S-C, 690 VAC IEC C No. of poles 1 S801S-C 2 S802S-C Rated current 10 13 16 20 25 32 40 50 63 80 100 125 10 13 16 20 25 32 40 50 63 80 100 125 Catalog number S801S-C10 S801S-C13 S801S-C16 S801S-C20 S801S-C25 S801S-C32 S801S-C40 S801S-C50 S801S-C63 S801S-C80 S801S-C100 S801S-C125 S802S-C10 S802S-C13 S802S-C16 S802S-C20 S802S-C25 S802S-C32 S802S-C40 S802S-C50 S802S-C63 S802S-C80 S802S-C100 S802S-C125 Tripping characteristic C s No. of poles Catalog number 10 13 16 20 25 32 40 50 63 80 100 125 10 13 16 20 25 32 40 50 63 80 100 125 3 4 S803S-C10 S803S-C13 S803S-C16 S803S-C20 S803S-C25 S803S-C32 S803S-C40 S803S-C50 S803S-C63 S803S-C80 S803S-C100 S803S-C125 S804S-C10 S804S-C13 S804S-C16 S804S-C20 S804S-C25 S804S-C32 S804S-C40 S804S-C50 S804S-C63 S804S-C80 S804S-C100 S804S-C125 10 000 IEC 690 VAC 50 kA 1000 Resistive loads • C Curve • Designed for use with medium magnetic start up currents • Example: lighting, control panels 100 Accessories & technical data S803S-C Rated current 10 Accessories – See page 15.52 Technical data – See page 15.76 - 15.82 seconds 1 15 0.1 0.01 1 S804S-C 2 3 5 10 20 30 multiple of rated current Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com e rs ur at ake i n e i M it br 0 u c S80 cir D S800S-D, 690 VAC IEC No. of poles 1 S801S-D 2 S802S-D Rated current 10 13 16 20 25 32 40 50 63 80 100 125 10 13 16 20 25 32 40 50 63 80 100 125 No. of poles Catalog number S801S-D10 S801S-D13 S801S-D16 S801S-D20 S801S-D25 S801S-D32 S801S-D40 S801S-D50 S801S-D63 S801S-D80 S801S-D100 S801S-D125 S802S-D10 S802S-D13 S802S-D16 S802S-D20 S802S-D25 S802S-D32 S802S-D40 S802S-D50 S802S-D63 S802S-D80 S802S-D100 S802S-D125 10 13 16 20 25 32 40 50 63 80 100 125 10 13 16 20 25 32 40 50 63 80 100 125 3 4 Catalog number S803S-D10 S803S-D13 S803S-D16 S803S-D20 S803S-D25 S803S-D32 S803S-D40 S803S-D50 S803S-D63 S803S-D80 S803S-D100 S803S-D125 S804S-D10 S804S-D13 S804S-D16 S804S-D20 S804S-D25 S804S-D32 S804S-D40 S804S-D50 S804S-D63 S804S-D80 S804S-D100 S804S-D125 10 000 Tripping characteristic D IEC 690 VAC 50 kA 1000 Inductive loads • D Curve • Designed for allowing higher in-rush currents during system start up • Example: motors, transformers 100 Accessories & technical data S803S-D Rated current 10 Accessories – See page 15.52 Technical data – See page 15.76 - 15.82 1 seconds 15 0.1 0.01 1 S804S-D 2 3 10 20 30 multiple of rated current Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com cir Min cu ia it b tur S8 rea e 00 ke r S800S-K, 690 VAC IEC K No. of poles 1 S801S-K 2 S802S-K Rated current 10 13 16 20 25 32 40 50 63 80 100 125 10 13 16 20 25 32 40 50 63 80 100 125 s No. of poles Catalog number S801S-K10 S801S-K13 S801S-K16 S801S-K20 S801S-K25 S801S-K32 S801S-K40 S801S-K50 S801S-K63 S801S-K80 S801S-K100 S801S-K125 S802S-K10 S802S-K13 S802S-K16 S802S-K20 S802S-K25 S802S-K32 S802S-K40 S802S-K50 S802S-K63 S802S-K80 S802S-K100 S802S-K125 Tripping characteristic K Rated current 10 13 16 20 25 32 40 50 63 80 100 125 10 13 16 20 25 32 40 50 63 80 100 125 3 4 Catalog number S803S-K10 S803S-K13 S803S-K16 S803S-K20 S803S-K25 S803S-K32 S803S-K40 S803S-K50 S803S-K63 S803S-K80 S803S-K100 S803S-K125 S804S-K10 S804S-K13 S804S-K16 S804S-K20 S804S-K25 S804S-K32 S804S-K40 S804S-K50 S804S-K63 S804S-K80 S804S-K100 S804S-K125 10 000 IEC 690 VAC 50 kA 1000 Inductive loads • K Curve • Designed for allowing higher in-rush currents during system start up • Example: motors, transformers 100 Accessories & technical data S803S-K Accessories – See page 15.52 Technical data – See page 15.76 - 15.82 10 15 seconds 1 S804S-K 0.1 0.01 1 2 3 10 20 30 multiple of rated current Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com e rs ur at ake i n e i M it br 0 u c S80 cir Accessories S800U & S800S UL & IEC Shunt trip For remote tripping of breaker, a shunt trip device can be added to the MCB. The device opens the breaker after control voltage is applied. Description (for field mounting, left side) Shunt operation release 24 VAC/DC Shunt operation release 48...130 VAC/DC Shunt operation release 110...250 VAC/DC Catalog number S800-SOR24 S800-SOR130 S800-SOR250 S800-SOR Undervoltage release When control voltage drops below approximately 50 % of rated voltage, the UVR opens the breaker. The breaker can not be operated unless proper control voltage is first applied to the UVR coil. Description Under voltage release 24...36 VAC/DC Under voltage release 48...60 VAC/DC Under voltage release 110...130 VAC/DC Under voltage release 220...250 VAC/DC Catalog number S800-UVR36 S800-UVR60 S800-UVR130 S800-UVR250 S800-UVR Auxiliary contacts The auxiliary contacts will signal whether the breaker is in the ON or OFF position. Description Auxiliary contact Catalog number S800-AUX S800-AUX 15 Bell alarm The bell alarm includes a set of contacts that will only signal when the breaker has tripped. Typically the contacts would be connected to an alarm or bell to signal the operator that an overcurrent trip has occurred. The bell alarm also includes a test button for testing the alarm contacts without opening the breaker. Description Bell alarm Catalog number S800-AUX/ALT S800-AUX/ALT Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com cir Min cu ia it b tur S8 rea e 00 ke r Accessories S800U & S800S UL & IEC s Ring tongue adaptor Description Ring terminal cable connection, 40-125A Catalog number S800-RT2125 S800-RT2125 Rotary operating mechanism Allows “through the door” operation. Description Handle mechanism Catalog number S800-RD S800-RD Description Grey rotary handle Catalog number S800-RHE-H S800-RHE-H Description Red rotary handle Catalog number S800-RHE-EM 15 S800-RHE-EM Description Shaft extension Catalog number S800-RHE-S S800-RHE-S UL Locking device Description Padlock not included Catalog number S800U-PLL S800U-PLL Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com e rs ur at ake i n e i M it br 0 u c S80 cir Technical data S800U UL S800U Characteristics K, Z Rated operational current Ie [A] 10...100 1...4 Pole Rated operational voltage Ue compliant to UL 489 (AC) 50/60 Hz [V] 240 Rated ultimate short-circuit breaking capacity compliant to UL489 (AC) 50/60 Hz 240 V Single-pole [kA] 30 (AC) 50/60 Hz 240 V Multipole [kA] 50 [V] 240/415 Rated operational voltage U e compliant to IEC 60947-2 (AC) Rated ultimate short-circuit breaking capacity I cu compliant to IEC 60947-2 (AC) 50/60 Hz 240/415 V Single-pole [kA] 30 (AC) 50/60 Hz 240/415 V Multipole [kA] 50 Rated service short-circuit breaking capacity I cs compliant to IEC 60947-2 (AC) 50/60 Hz 240/415 V Single-pole [kA] 25 (AC) 50/60 Hz 240/415 V Multipole [kA] 40 Connections C u 10...30 A 14 – 2 AWG 40...100 A 8 –1 AWG Rated frequency 50/60 Tightening torque [Hz] 3,5 (31 in.lb.) Protection category [Nm] IP40 (actuating end only) Mounting position any Contacts cadmium-free Permissible ambient temperature Standards [°C] –25...+60 UL 489 IEC 60947-2 CSA22.2 NO.5-02 Approval cULus File E312425 15 Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com cir Min cu ia it b tur S8 rea e 00 ke r Technical data S800U UL Typical internal resistances and power losses at 25 °C ambient temperature Influence of ambient temperature s Rated current In Internal resistance Ri Power loss Pv [A] [mΩ] [W] K, Z K, Z 10 15.2 1.5 15 12.1 2.7 20 8.7 3.5 25 6.8 4.2 30 3.1 2.8 40 2.3 3.7 50 1.7 4.3 60 1.6 5.8 70 1.0 4.9 80 1.0 6.4 90 0.8 6.5 100 0.8 8.3 Devices mounted singly (specifications in A) S800U-K, -Z In [A] 10 °C 15 ° C 20 ° C 25 ° C 30 ° C 35 ° C 40 ° C 45 ° C 50 °C 55 ° C 60 ° C 10 10.9 10.7 10.4 10.0 9.6 9.3 9.0 8.7 8.4 8.0 7.6 15 16.5 16.0 15.6 15.0 14.4 14.0 13.5 13.0 12.6 12.0 11.4 20 22.0 21.4 20.8 20.0 19.2 18.6 18.0 17.4 16.8 16.0 15.2 25 27.5 26.8 26.0 25.0 24.0 23.3 22.5 21.8 21.0 20.0 19.0 30 33.1 32.1 31.2 30.0 28.8 27.9 27.0 26.1 25.2 24.0 22.9 40 44.0 42.8 41.6 40.0 38.4 37.2 36.0 34.8 33.6 32.0 30.9 50 55.1 53.5 52.0 50.0 48.0 46.5 45.0 43.5 42.0 40.0 38.3 60 66.2 64.2 62.4 60.0 57.6 55.8 54.0 52.2 50.4 48.0 46.0 70 76.9 74.9 72.8 70.0 67.2 65.1 63.0 60.9 58.8 56.0 53.4 80 88.0 85.6 83.2 80.0 76.8 74.4 72.0 69.6 67.1 64.0 61.6 90 99.1 96.3 93.6 90.0 86.4 83.7 81.0 78.3 75.6 72.0 69.5 100 110.5 107.0 104.0 100.0 96.0 93.0 90.0 87.0 83.8 80.0 77.8 Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com 15 e rs ur at ake i n e i M it br 0 u c S80 cir Technical data S800S IEC Internal resistance and power loss Internal resistance per pole in mz, power loss per pole in W Type S800S Rated current A Device series BCDK Power loss BCDK mz W 10 13 16 15.2 12.1 12.1 1.5 2.0 3.1 20 25 32 8.7 6.8 3.1 3.5 4.2 3.1 40 50 63 2.3 1.7 1.6 3.7 4.3 6.2 80 100 125 1.0 0.8 0.6 6.4 8.3 9.4 Temperature derating Max. operating current values depending on the ambient temperature for a circuit-breaker in load circuit of type B, C, D, & K characteristics. S800S-B, -C, -D In [A] 10 13 16 20 25 32 40 50 63 80 100 125 Ambient temperature T (°C/°F) 10/50 11.2 14.6 17.9 22.4 28.0 35.8 44.8 56.0 70.6 89.6 112.0 140.0 15/59 11.0 14.3 17.6 22.0 27.5 35.2 44.0 55.0 69.3 88.0 110.0 137.5 20/68 10.7 13.9 17.1 21.4 26.8 34.2 42.8 53.5 67.4 85.6 107.0 133.8 25/77 10.4 13.5 16.6 20.8 26.0 33.3 41.6 52.0 65.5 83.2 104.0 130.0 10/50 11.9 15.6 19.1 23.9 29.9 38.2 47.8 59.7 75.3 95.6 119.5 149.4 15/59 11.6 15.1 18.6 23.2 29.1 37.2 46.5 58.1 73.2 93.0 116.2 145.3 20/68 11.2 14.6 17.9 22.4 28.0 35.8 44.8 56.0 70.6 89.6 112.0 140.0 25/77 11.0 14.3 17.6 22.0 27.5 35.2 44.0 55.0 69.3 88.0 110.0 137.5 30/86 10.0 13.0 16.0 20.0 25.0 32.0 40.0 50.0 63.0 80.0 100.0 125.0 35/95 9.6 12.5 15.4 19.2 24.0 30.7 38.4 48.0 60.5 76.8 96.0 120.0 40/104 9.3 12.1 14.9 18.6 23.3 29.8 37.2 46.5 58.6 74.4 93.0 116.3 45/113 9.0 11.7 14.4 18.0 22.5 28.8 36.0 45.0 56.7 72.0 90.0 112.5 50/122 8.7 11.3 13.9 17.4 21.8 27.8 34.8 43.5 54.8 69.6 87.0 108.8 55/131 8.4 10.9 13.4 16.8 21.0 26.9 33.6 42.0 52.9 67.2 84.0 105.0 60/140 8.0 10.4 12.8 16.0 20.0 25.6 32.0 40.0 50.4 64.0 80.0 100.0 50/122 9.3 12.1 14.9 18.6 23.3 29.8 37.2 46.5 58.6 74.4 93 116.3 55/131 9.0 11.7 14.4 18.0 22.5 28.8 36.0 45.0 56.7 72.0 90.0 112.5 60/140 8.7 11.3 13.9 17.4 21.8 27.8 34.8 43.5 54.8 69.6 87.0 108.8 15 S800S-K In [A] 10 13 16 20 25 32 40 50 63 80 100 125 Ambient temperature T (°C/°F) 30/86 10.7 13.9 17.1 21.4 26.8 34.2 42.8 53.5 67.4 85.6 107.0 133.8 35/95 10.4 13.5 16.6 20.8 26.0 33.3 41.6 52.0 65.5 83.2 104.0 130.0 40/104 10.0 13.0 16.0 20.0 25.0 32.0 40.0 50.0 63.0 80.0 100.0 125.0 45/113 9.6 12.5 15.4 19.2 24.0 30.7 38.4 48.0 60.5 76.8 96.0 120.0 Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com cir Min cu ia it b tur S8 rea e 00 ke r Technical data S800S IEC Tripping Characteristic B s Tripping Characteristic C Tripping Characteristic D 1000 1000 1000 100 100 100 10 10 10 1 1 1 0.1 seconds 10 000 seconds 10 000 seconds 10 000 0.1 0.01 0.01 1 2 3 5 10 20 0.01 1 30 2 3 5 10 20 30 multiple of rated current multiple of rated current Tripping Characteristic K 0.1 1 2 3 10 20 30 multiple of rated current Tripping Characteristic Z 10 000 10 000 1000 1000 100 100 10 10 1 1 seconds seconds 15 0.1 0.01 0.1 0.01 1 2 3 multiple of rated current 10 20 30 1 2 3 5 10 20 30 multiple of rated current Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com e rs ur at ake i n e i M it br 0 u c S80 cir Technical data S800U & S800S Accessories Auxiliary contact S800-AUX S800-AUX AC15 400/2 A-UL AC15 240/ -UL DC13 250/0.55 A125 V/1.1A-IEC DC13 125 V/1.1A DC13 60 V/2A DC13 24 V/4A 6A 690 V 2 6 kV 3 Changeover contacts 1 x 2.5 mm2 2 x 1.5 mm2 1 Nm 5g, 20 frequency cycle at 24 VAC/DC, 5mA brief interrupt <10 ms any EN 60715 EN 60715 IP20 IP20 -25...+60 °C; -13 °F... 140 °F -40...+70 °C; -40 °F... 158 °F 6000 switching cycles 1000 A IEC 60068-2-27; IEC 60068-2; EN 61373 Cat.1/class B Usage category Continuous thermal current In Rated insulation voltage Ui Number of contacts Surge Utest (1.2/50µs) Degree of protection Function of contact Connection Cu Tightening torque Ensured contacts during shake test acc. to IEC 68-2-6 AC/DC supply Mounting on DIN top hat rail Type of protection Permissible ambient temperature for operations Storage temperature Mechanical device service life Icu with S450E Resistance to vibration Undervoltage release S800-UVR S800-UVR36 24...36 VAC/DC Rated voltage Ue 15 S800-UVR60 48...60 VAC/DC S800-UVR130 110...130 VAC/DC S800-UVR250 220...250 VAC/DC Operating range Operating opening 35...70% Ue Operating clothing 85% Ue 690 V Rated insulation voltage Ui Coil pull in consumption Rated frequency 1 W, 14 vA 1 W, 25 vA 1 W, 41 vA 1 W, 91 vA DC; 50/60 Hz Protection degree Connection Cu 3 1...35 cable Tightening torque min.3/ max.4 Nm AC/DC supply any DIN top hat rail EN 60715 Type of protection Permissible ambient temperature of operations Storage temperature Resistance to vibration IP20 IP40 (only actuation side) -25...+60 °C; -13 °F... 140 °F -40...+70 °C; -40 °F... 158 °F IEC 60068-2-27; IEC 60068-2; EN61373 Cat.1/class B Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com cir Min cu ia it b tur S8 rea e 00 ke r Technical data S800U & S800S Accessories s Combined auxiliary and bell alarm Usage category Continuous thermal current In Rated insulation voltage Ui Number of contacts Surge Utest (1.2/50µs) Degree of protection Function of contact Connection Cu Tightening torque Ensured contacts during shake test acc. to IEC 68-2-6 AC/DC supply Mounting on DIN top hat rail Type of protection Permissible ambient temperature for operations Storage temperature mech. Device service life Icu with S450E Resistance to vibration AC15 400/2A-UL AC15 240/6A-UL DC13 250/0.55A125V/1.1A-IEC DC13 125V/1.1A-IEC DC13 60V/2A DC13 24V/4A 6A 690 V 2 (1x AUX, 1 x AUX/ALT) 6 kV 3 Changeover contacts 1 x 2.5 mm2 2 x 1.5 mm2 1 Nm 5g, 20 frequency cycle 5...150...5Hz at 24VAC/DC, 5mA brief interrupt <10ms any EN 60715 EN 60715 IP20 -25 °C... 60 °C; -13 °F... 140 °F -40 °C... 70 °C; -40 °F... 150 °F 6000 switching cycles 1000 A IEC 60068-2-27; IEC 60068-2; EN 61373 Cat.1/class B Shunt operation release – S800-SOR Rated voltage Ue Operating range Rated insulation voltage Ui Coil pull in consumption Rated frequency Degree of protection Connection Cu Tightening torque AC/DC supply DIN top hat rail Type of protection Permissible ambient temperature of operations Storage temperature Resistance to vibration S800-SOR24 24 VAC/DC 19.2 W/vA S800-SOR130 S800-SOR250 48...130 VAC/DC 110...250 VAC/DC 70... 110% Ue 690 V On request DC; 50/60 Hz 3 1...35 AWG min.3/ max.4 Nm any EN 60715 IP20; IP40 (only actuation side) -25 °C... 60 °C; -13 °F... 140 °F S800-SOR400 220...250 -40 °C... 70 °C; -40 °F... 158 °F IEC 60068-2-27; IEC 60068-2; EN61373 Cat.1/class B Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com 15 e rs ur at ake i n e i M it br 0 u c S80 cir Technical data Backup S800S - S200 @ 230/400 V E. Char. Icu [kA] L. S200 B 6 In [A] 6 10 13 16 20 25 32 40 50 63 25 50 50 50 50 32 50 50 50 50 50 40 50 50 50 50 50 50 S800S B, C, D, K 50 50 63 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 E. Char. Icu [kA] L. 80 50 50 50 50 50 50 50 50 50 100 125 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 25 S200P B 15 In [A] 6…16 20 25 32 40 50 63 25 50 32 50 50 40 50 50 50 E. Char. Icu [kA] L. E. Char. Icu [kA] L. [A] 0.5…6 8 10 13 16 20 25 32 40 50 63 In S200 C 6 25 50 50 50 50 50 32 50 50 50 50 50 50 40 50 50 50 50 50 50 50 S800S B, C, D, K 50 50 63 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 25 80 50 50 50 50 50 50 50 50 50 50 100 125 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 S200P C 15 25 In [A] 0.5…16 50 20 25 32 40 50 63 32 50 50 40 50 50 50 S800S B, C, D, K 50 50 63 50 50 50 50 50 50 50 50 50 S800S B, C, D, K 50 50 63 50 50 50 50 50 50 50 50 50 80 50 50 50 50 50 50 100 125 50 50 50 50 50 50 50 50 50 50 50 50 50 50 80 50 50 50 50 50 50 100 125 50 50 50 50 50 50 50 50 50 50 50 50 50 50 LEGEND E. = supply side L. = load side Back-up limit values are specified in kA 15 Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com cir Min cu ia it b tur S8 rea e 00 ke r Technical data Selectivity S800S - S200 @ 230/400 V E. Char. Icu [kA] L. S200 B 6 In [A] 6 10 13 16 20 25 32 40 50 63 25 32 40 0.4 E. Char. Icu [kA] L. S200 C 6 In [A] 0.5 1 1.6 2 3 4 6 8 10 13 16 20 25 32 40 50 63 25 T 3.3 0.6 0.4 32 T T 1.3 0.7 0.4 0.4 40 T T T 1.3 0.6 0.6 0.4 S800S B 50 50 63 0.5 0.7 0.4 0.6 0.5 S800S B 50 50 63 T T T T T T T T 0.7 1.1 0.7 1 0.5 0.7 0.4 0.6 0.4 0.6 0.5 s E. Char. Icu [kA] L. 80 1 0.7 0.7 0.7 80 T T T T 2.6 1.7 1 0.7 0.7 0.7 0.7 100 1.5 1 0.9 0.9 0.9 0.9 0.8 0.8 100 T T T T T 3.1 1.5 1 1 0.9 0.9 0.9 0.9 0.8 0.8 125 2.6 1.4 1.3 1.3 1.3 1.3 1.1 1.1 1 0.9 125 T T T T T T 2.6 1.4 1.4 1.3 1.3 1.3 1.3 1.1 1.1 1 0.9 S200 D 6 In [A] 0.5 1 1.6 2 3 4 6 8 10 13 16 20 25 32 40 50 63 25 T 0.8 0.5 0.3 32 T 4.5 1 0.5 0.4 0.4 40 T T 2.3 0.7 0.5 0.4 E. Char. Icu [kA] L. S200 K 6 In [A] 0.5 1 1.6 2 3 4 6 8 10 13 16 20 25 32 40 50 63 25 T 0.8 0.5 0.3 32 T 5 1 0.5 0.4 0.4 40 T T 2.1 0.7 0.5 0.4 S800S B 50 50 63 T T T T T T 2.3 T 0.7 1.2 0.7 1 0.6 0.8 0.7 S800S B 50 50 63 T T T T T T 2.1 T 0.7 1.2 0.7 1 0.6 0.8 0.7 80 T T T T 2.5 1.7 1.2 0.9 0.9 100 T T T T T 3 2 1.3 1.3 1 125 T T T T T T 3.6 2 2 1.5 1.5 80 T T T T 2.5 1.7 1.2 0.9 0.9 100 T T T T T 3 2 1.3 1.3 1 125 T T T T T T 3.6 2 2 1.5 1.5 15 LEGEND E. = supply side L. = load side Back-up limit values are specified in kA Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com e rs ur at ake i n e i M it br 0 u c S80 cir Technical data Selectivity S800S - S200 @ 230/400 V E. Char. Icu [kA] L. S200 B 6 In [A] 6 10 13 16 20 25 32 40 50 63 25 32 0.4 0.3 0.3 0.3 40 0.5 0.4 0.4 0.4 0.4 0.4 S800S C 50 50 63 0.7 0.9 0.5 0.7 0.5 0.7 0.5 0.7 0.5 0.7 0.5 0.7 0.5 0.6 0.6 E. 80 1.4 0.9 0.9 0.9 0.9 0.9 0.8 0.8 0.7 100 2.4 1.3 1.3 1.3 1.2 1.2 1 1 0.9 0.9 125 4.8 2 1.9 1.9 1.8 1.8 1.4 1.4 1.3 1.2 Char. Icu L. S200 E. Char. Icu [kA] L. S200 C 6 In [A] 0.5 1 1.6 2 3 4 6 8 10 13 16 20 25 32 40 50 63 25 T T 0.6 0.5 0.3 0.3 32 T T T 1 0.5 0.4 0.4 0.3 0.3 0.3 0.3 40 T T T T 0.7 0.7 0.5 0.4 0.4 0.4 0.4 0.4 0.4 S800S C 50 50 63 T T T T T T T T 1.2 2.1 1 1.5 0.7 0.9 0.5 0.7 0.5 0.7 0.5 0.7 0.5 0.7 0.5 0.7 0.5 0.7 0.5 0.6 0.6 80 T T T T T 2.6 1.4 0.9 0.9 0.9 0.9 0.9 0.9 0.8 0.8 0.7 100 T T T T T T 2.4 1.3 1.3 1.3 1.3 1.2 1.2 1 1 0.9 0.9 125 T T T T T T 4.8 2 2 1.9 1.9 1.8 1.8 1.4 1.4 1.3 1.2 D [kA] 6 In [A] 0.5 1 1.6 2 3 4 6 8 10 13 16 20 25 32 40 50 63 25 T 2.1 0.8 0.4 0.3 0.3 32 T T 2.3 0.7 0.5 0.4 0.4 40 T T T 2.3 0.7 0.7 0.6 0.5 E. Char. Icu [kA] L. S200 15 K 6 In [A] 0.5 1 1.6 2 3 4 6 8 10 13 16 20 25 32 40 50 63 25 T 2.1 0.8 0.4 0.3 0.3 32 T T 2.3 0.7 0.5 0.4 0.4 40 T T T 2.3 0.7 0.7 0.6 0.5 S800S C 50 50 63 T T T T T T T T 1.2 2.2 1 1.4 0.8 1.1 0.7 0.9 0.7 0.9 0.7 S800S C 50 50 63 T T T T T T T T 1.2 2.2 1 1.4 0.8 1.1 0.7 0.9 0.7 0.9 0.7 80 T T T T T 2.6 1.8 1.2 1.2 1 1 100 T T T T T T 3.2 1.8 1.8 1.4 1.4 1 125 T T T T T T T 2.8 2.8 2 2 1.4 1.4 80 T T T T T 2.6 1.8 1.2 1.2 1 1 100 T T T T T T 3.2 1.8 1.8 1.4 1.4 1 125 T T T T T T T 2.8 2.8 2 2 1.4 1.4 LEGEND E. = supply side L. = load side Back-up limit values are specified in kA Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com cir Min cu ia it b tur S8 rea e 00 ke r Technical data Selectivity S800S - S200 @ 230/400 V E. Char. Icu [kA] L. S200 B 6 In [A] 6 10 13 16 20 25 32 40 50 63 25 0.5 0.4 0.4 32 1 0.6 0.6 0.6 40 1.2 0.8 0.8 0.8 0.8 0.8 E. Char. Icu [kA] L. S200 C 6 In [A] 0.5 1 1.6 2 3 4 6 8 10 13 16 20 25 32 40 50 63 25 T T T T 0.7 0.7 0.5 0.4 0.4 0.4 32 T T T T 2.2 1.3 1 0.6 0.6 0.6 0.6 40 T T T T 4.4 2.2 1.2 0.8 0.8 0.8 0.8 0.8 0.8 S800S D 50 50 63 2 2.8 1.1 1.4 1.1 1.4 1.1 1.4 1.1 1.3 1.1 1.3 0.9 1.1 1.1 S800S D 50 50 63 T T T T T T T T T T 4.4 T 2 2.8 1.1 1.4 1.1 1.4 1.1 1.4 1.1 1.4 1.1 1.3 1.1 1.3 0.9 1.1 1.1 s E. Char. Icu [kA] L. 80 T 2.8 2.5 2.5 2.3 2.3 1.9 1.9 1.5 100 T 3.9 3.3 3.3 3 3 2.4 2.4 1.9 1.7 125 T T T 5.6 4.7 4.7 3.7 3.7 2.3 2.3 80 T T T T T T T 2.8 2.8 2.5 2.5 2.3 2.3 1.9 1.9 1.5 100 T T T T T T T 3.9 3.9 3.3 3.3 3 3 2.4 2.4 1.9 1.7 125 T T T T T T T T T 5.6 5.6 4.7 4.7 3.7 3.7 2.3 2.3 S200 D 6 In [A] 0.5 1 1.6 2 3 4 6 8 10 13 16 20 25 32 40 50 63 25 T T T 2.3 0.7 0.7 0.6 0.5 0.5 32 T T T T 1.3 1 0.8 0.7 0.7 0.6 40 T T T T 4.4 2.2 1.5 1.1 1.1 0.9 0.9 E. Char. Icu [kA] L. S200 K 6 In [A] 0.5 1 1.6 2 3 4 6 8 10 13 16 20 25 32 40 50 63 25 T T T 2.3 0.7 0.7 0.6 0.5 0.5 32 T T T T 1.3 1 0.8 0.7 0.7 0.6 40 T T T T 4.4 2.2 1.5 1.1 1.1 0.9 0.9 S800S D 50 50 63 T T T T T T T T T T 4.4 T 2.5 3.6 1.5 2 1.5 2 1.2 1.5 1.2 1.5 0.9 1.1 1.1 S800S D 50 50 63 T T T T T T T T T T 4.4 T 2.5 3.6 1.5 2 1.5 2 1.2 1.5 1.2 1.5 0.9 1.1 1.1 80 T T T T T T T 4 4 2.6 2.6 1.8 1.8 1.7 100 T T T T T T T 5.5 5.5 3.4 3.4 2.2 2.2 2 1.9 125 T T T T T T T T T 5.2 5.2 3.2 3.2 2.9 2.6 2.2 80 T T T T T T T 4 4 2.6 2.6 1.8 1.8 1.7 100 T T T T T T T 5.5 5.5 3.4 3.4 2.2 2.2 2 1.9 125 T T T T T T T T T 5.2 5.2 3.2 3.2 2.9 2.6 2.2 LEGEND E. = supply side L. = load side Back-up limit values are specified in kA Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com 15 e rs ur at ake i n e i M it br 0 u c S80 cir Technical data Selectivity S800S - S200 @ 230/400 V E. Char. Icu [kA] L. 25 S200P B 15 In [A] 6 10 13 16 20 25 32 40 50 63 25 32 40 0.4 E. Char. Icu L. [kA] 25 S200P C 15 In [A] 0.5 1 1.6 2 3 4 6 8 10 13 16 20 25 32 40 50 63 25 T 3.3 0.6 0.4 32 T T 1.3 0.7 40 T T T 1.2 0.6 0.6 0.4 E. Char. Icu [kA] L. 15 25 S200P K 15 In [A] 0.2 0.3 0.5 0.75 1 1.6 2 3 4 6 8 10 13 16 20 25 32 40 50 63 25 T T T T 0.8 0.5 0.3 32 T T T T 5 1 0.5 0.4 0.4 40 T T T T T 2.3 0.7 0.5 0.4 S800S B 50 50 63 0.5 0.7 0.4 0.6 0.5 S800S B 50 50 63 T T T T T T T T 0.7 1.1 0.7 1 0.5 0.7 0.4 0.6 0.4 0.6 0.5 S800S B 50 50 63 T T T T T T T T T T T T 2.1 T 0.7 1.2 0.7 1 0.6 0.8 0.7 E. Char. Icu [kA] L. 80 1 0.7 0.7 0.7 100 1.5 1 0.9 0.9 0.9 0.9 0.8 0.8 125 2.6 1.4 1.3 1.3 1.3 1.3 1.1 1.1 1 0.9 25 S200P B 15 In [A] 6 10 13 16 20 25 32 40 50 63 25 32 40 0.4 E. Char. L. 80 T T T T 2.6 1.7 1 0.7 0.7 0.7 0.7 100 T T T T 8.8 3.1 1.5 1 1 0.9 0.9 0.9 0.9 0.8 0.8 125 T T T T T 7 2.6 1.4 1.4 1.3 1.3 1.3 1.3 1.1 1.1 1 0.9 Icu [kA] 25 S200P C 15 In [A] 0.5 1 1.6 2 3 4 6 8 10 13 16 20 25 32 40 50 63 25 T 3.3 0.6 0.4 32 T T 1.3 0.7 0.4 0.4 40 T T T 1.3 0.6 0.6 0.4 E. Char. Icu [kA] L. 80 T T T T T T T 2.5 1.7 1.2 0.9 0.9 100 T T T T T T T 8.6 3 2 1.3 1.3 1 125 T T T T T T T T 7.7 3.6 2 2 1.5 1.5 25 S200P K 15 In [A] 0.2 0.3 0.5 0.75 1 1.6 2 3 4 6 8 10 13 16 20 25 32 40 50 63 25 T T T T 0.8 0.5 0.3 32 T T T T 5 1 0.5 0.4 0.4 40 T T T T T 2.3 0.7 0.5 0.4 S800S C 50 50 63 0.5 0.7 0.4 0.6 0.5 S800S C 50 50 63 T T T T T T T T 0.7 1.1 0.7 1 0.5 0.7 0.4 0.6 0.4 0.6 0.5 S800S C 50 50 63 T T T T T T T T T T T T 2.3 T 0.7 1.2 0.7 1 0.6 0.8 0.7 80 1 0.7 0.7 0.7 100 1.5 1 0.9 0.9 0.9 0.9 0.8 0.8 125 2.6 1.4 1.3 1.3 1.3 1.3 1.1 1.1 1 0.9 80 T T T T 2.6 1.7 1 0.7 0.7 0.7 0.7 100 T T T T 8.8 3.1 1.5 1 1 0.9 0.9 0.9 0.9 0.8 0.8 125 T T T T T 7 2.6 1.4 1.4 1.3 1.3 1.3 1.3 1.1 1.1 1 0.9 80 T T T T T T T 2.5 1.7 1.2 0.9 0.9 100 T T T T T T T 8.6 3 2 1.3 1.3 1 125 T T T T T T T T 7.7 3.6 2 2 1.5 1.5 LEGEND E. = supply side L. = load side Back-up limit values are specified in kA Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com cir Min cu ia it b tur S8 rea e 00 ke r Technical data Selectivity S800S - S200P @ 230/400 V E. Char. Icu [kA] L. 25 S200P B 15 In [A] 6 10 13 16 20 25 32 40 50 63 25 0.5 0.4 0.4 32 1 0.6 0.6 0.6 40 1.2 0.8 0.8 0.8 0.8 0.8 S800S D 50 50 63 2 2.8 1.1 1.4 1.1 1.4 1.1 1.4 1.1 1.3 1.1 1.3 0.9 1.1 1.1 E. Char. 80 9.9 2.8 2.5 2.5 2.3 2.3 1.9 1.9 1.5 100 21.3 3.9 3.3 3.3 3 3 2.4 2.4 1.9 1.7 125 T 7.4 5.6 5.6 4.7 4.7 3.7 3.7 2.3 2.3 E. Icu [kA] L. 25 S200P C 15 In [A] 0.5 1 1.6 2 3 4 6 8 10 13 16 20 25 32 40 50 63 25 T T T T 0.7 0.7 0.5 0.4 0.4 0.4 32 T T T T 2.2 1.3 1 0.6 0.6 0.6 0.6 40 T T T T 4.4 2.2 1.2 0.8 0.8 0.8 0.8 0.8 0.8 S800S D 50 50 63 T T T T T T T T T T 4.4 7.7 2 2.8 1.1 1.4 1.1 1.4 1.1 1.4 1.1 1.4 1.1 1.3 1.1 1.3 0.9 1.1 1.1 80 T T T T T T 9.9 2.8 2.8 2.5 2.5 2.3 2.3 1.9 1.9 1.5 100 T T T T T T 22 3.9 3.9 3.3 3.3 3 3 2.4 2.4 1.9 1.7 Icu [kA] L. 25 S200P Char. s 125 T T T T T T T 7.4 7.4 5.6 5.6 4.7 4.7 3.7 3.7 2.3 2.3 K 15 In [A] 0.2 0.3 0.5 0.75 1 1.6 2 3 4 6 8 10 13 16 20 25 32 40 50 63 25 T T T T T T 2.3 0.7 0.7 0.6 0.5 0.5 32 T T T T T T T 1.3 1 0.8 0.7 0.7 0.6 40 T T T T T T T 4.4 2.2 1.5 1.1 1.1 0.9 0.9 S800S D 50 50 63 T T T T T T T T T T T T T T T T 4.4 7.7 2.5 3.6 1.5 2 1.5 2 1.2 1.5 1.2 1.5 0.9 1.1 80 100 125 T T T T T T T T T T T T T T T T T T T T T T T T T T T 12.1 24.2 T 4 5.5 9.9 4 5.5 9.9 2.6 3.4 5.2 2.6 3.4 5.2 1.8 2.2 3.2 1.8 2.2 3.2 1.7 2 2.9 1.9 2.6 2.2 LEGEND E. = supply side L. = load side Back-up limit values are specified in kA 15 Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com e rs ur at ake i n e i M it br 0 u c S80 cir Technical data Selectivity S800S - S280 @ 230/400 V E. Char. L. Icu [kA] 10 25 S280 B 15 10 In [A] 6 10 13 16 20 25 32 40 50 63 25 50 50 50 50 32 50 50 50 50 50 40 50 50 50 50 50 50 E. Icu [kA] 10 S280 C 25 15 10 S280 K, Z 25 15 10 125 50 16 16 16 16 16 16 16 16 16 Icu [kA] S400E B 6 In [A] 6 10 13 16 20 25 32 40 50 63 25 50 50 50 50 32 50 50 50 50 50 40 50 50 50 50 50 50 E. L. 40 50 50 50 50 50 50 50 50 50 25 25 63 50 50 50 20 20 80 50 50 50 16 16 100 50 50 50 16 16 125 50 50 50 16 16 13 16 20 25 32 40 50 63 50 50 50 50 50 50 50 50 50 25 25 25 25 25 20 20 20 20 20 20 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 80 50 50 50 16 16 100 50 50 50 16 16 125 50 50 50 16 16 In [A] 3 4 6 8 10 25 50 50 50 50 50 32 50 50 50 50 50 40 50 50 50 50 50 S800S B, C, D, K 50 50 63 50 50 50 50 50 50 25 20 25 20 13 50 50 50 25 20 16 16 16 16 20 25 32 40 50 63 50 50 50 50 50 50 25 25 25 25 20 20 20 20 20 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 Icu [kA] In [A] 0.5…6 8 10 13 16 S400E C 6 20 25 32 40 50 63 S800S B, C, D, K 50 50 63 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 80 50 50 50 50 50 50 50 50 50 100 50 50 50 50 50 50 50 50 50 50 125 50 50 50 50 50 50 50 50 50 50 S800S B, C, D, K 50 Char. 32 50 50 50 50 50 Icu [kA] 10 100 50 16 16 16 16 16 16 16 16 16 25 50 50 50 50 50 E. 15 L. 80 50 16 16 16 16 16 16 16 16 In [A] 3 4 6 8 10 Char. L. E. Char. S800S B, C, D, K 50 Char. L. S800S B, C, D, K 50 50 63 50 50 25 20 25 20 25 20 25 20 25 20 25 20 20 25 50 50 50 50 50 32 50 50 50 50 50 40 50 50 50 50 50 50 50 50 50 50 50 63 50 50 50 50 50 80 50 50 50 50 50 100 50 50 50 50 50 125 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 LEGEND E. = supply side L. = load side Back-up limit values are specified in kA Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com cir Min cu ia it b tur S8 rea e 00 ke r Approximate dimensions S800U & S800S UL & IEC s Dimension drawings in mm S800-SOR & S800-UVR S800S & S800U 106 6 82.5 79.5 6 26.5 82.5 76.5 53 76.5 46 46 45 95 45 95 35 95 2CCC413010Z0001 35 45 26.5 1P 2P 3P 4P S800-AUX S800-AUX/ALT 9 9 6 6 82.5 82.5 76.5 76.5 46 46 T 2CCC413018Z0001 95 RT 2CCC413017Z0001 35 45 35 T 15 S800-RD & S800-RHE 81 67 76 48 76 max. 500mm Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com cir Min cu ia it b tur S5 rea e 00 ke r S500 UL 1077 Series Miniature circuit breakers S500 Series UL 1077 s Description Features The S500 high performance MCB offers a compact solution to circuit protection. The S500 devices are UL tested current limiting and DIN rail mounted. The S500 is available with application-specific trip characteristics to provide maximum circuit protection. • • • • • • • • • • • • The breakers offer thermal-magnetic trip protection according to B and K characteristics. For the worldwide market, the breakers carry CSA, IEC, CE and many other agency approvals. High breaking capacity Fast breaking time (2.3 - 2.5 ms) Adjustable trip unit DIN rail mounting Finger safe terminals Multi-functional terminals Wide range of accessories UL 1077 recognized 600 VAC and 600 VDC versions UL1077 AC adjustable K UL1077 DC adjustable B, K UL File # E167556 IEC #E60497-2 S500 Amperage Voltage S500UC 0.1 – 45 A 0.1 – 63 A UL: 600Y/277 VAC IEC: 690 VAC UL: 250 VDC per pole (600 VDC for 4P) IEC: 250 VDC per pole (750 VDC for 4P) 1, 2, 3 1, 2, 3, 4 Trip characteristics K B, K Interrupting ratings Up to 30 kA : UL 1077 Up to 30 kA: CSA C22.2 30 kA : UL 1077 30 kA: CSA C22.2 Auxiliary contacts Yes Yes Bell alarm Yes Yes Shunt trip No No Undervoltage release No No Bus bar Yes Yes Poles Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com 15 re s tu ker a i in ea M it br 0 cu S50 cir K S500-K, UL 600Y/277 VAC / IEC 690 VAC Supplemental protection UL 1077, CSA 22.2, IEC No. of poles 1 S501-K S502-K 2 S503-K Catalog number 0.1 – 0.15 0.14 – 0.21 0.2 – 0.3 0.28 – 0.42 0.38 – 0.58 0.53 – 0.8 0.73 – 1.1 1 – 1.5 1.4 – 2.1 2 – 3 2.8 – 4.2 3.8 – 5.8 5.3 – 8 7.3 – 11 10 – 15 14 – 20 18 – 26 23 – 32 29 – 37 34 – 41 38 – 45 0.1 – 0.15 0.14 – 0.21 0.2 – 0.3 0.28 – 0.42 0.38 – 0.58 0.53 – 0.8 0.73 – 1.1 1 – 1.5 1.4 – 2.1 2 – 3 2.8 – 4.2 3.8 – 5.8 5.3 – 8 7.3 – 11 10 – 15 14 – 20 18 – 26 23 – 32 29 – 37 34 – 41 38 – 45 S501-K0.15 S501-K0.21 S501-K0.3 S501-K0.42 S501-K0.58 S501-K0.8 S501-K1.1 S501-K1.5 S501-K2.1 S501-K3 S501-K4.2 S501-K5.8 S501-K8 S501-K11 S501-K15 S501-K20 S501-K26 S501-K32 S501-K37 S501-K41 S501-K45 S502-K0.15 S502-K0.21 S502-K0.3 S502-K0.42 S502-K0.58 S502-K0.8 S502-K1.1 S502-K1.5 S502-K2.1 S502-K3 S502-K4.2 S502-K5.8 S502-K8 S502-K11 S502-K15 S502-K20 S502-K26 S502-K32 S502-K37 S502-K41 S502-K45 No. of poles Rated current Catalog number 0.1 – 0.15 0.14 – 0.21 0.2 – 0.3 0.28 – 0.42 0.38 – 0.58 0.53 – 0.8 0.73 – 1.1 1 – 1.5 1.4 – 2.1 2 – 3 2.8 – 4.2 3.8 – 5.8 5.3 – 8 7.3 – 11 10 – 15 14 – 20 18 – 26 23 – 32 29 – 37 34 – 41 38 – 45 3 S503-K0.15 S503-K0.21 S503-K0.3 S503-K0.42 S503-K0.58 S503-K0.8 S503-K1.1 S503-K1.5 S503-K2.1 S503-K3 S503-K4.2 S503-K5.8 S503-K8 S503-K11 S503-K15 S503-K20 S503-K26 S503-K32 S503-K37 S503-K41 S503-K45 10,000 Tripping characteristic K UL 1077 IEC 600 VAC Up to 30 kA 690 VAC Up to 30 kA 5000 1000 500 Inductive loads • K Curve • Designed for allowing higher in-rush currents during system start up • Example: motors, transformers 100 50 10 5 Accessories & technical data Accessories – See page 15.71 Technical data – See page 15.76 - 82 seconds 15 Rated current 1 0.5 AC 0.1 0.05 0.01 1 2 3 5 8 10 12 20 30 multiple of rated current Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com cir Min cu ia it b tur S5 rea e 00 ke r S500UC-B, 250 VDC per pole (600 VDC 4P) UL/IEC (750 VDC 4P) Supplemental protectors, UL1077, CSA 22.2, IEC B No. of poles 1 S501UC-B 2 Rated current Catalog number 6 10 13 16 20 25 32 40 50 63 6 10 13 16 20 25 32 40 50 63 No. of poles S501UC-B6 S501UC-B10 S501UC-B13 S501UC-B16 S501UC-B20 S501UC-B25 S501UC-B32 S501UC-B40 S501UC-B50 S501UC-B63 S502UC-B6 S502UC-B10 S502UC-B13 S502UC-B16 S502UC-B20 S502UC-B25 S502UC-B32 S502UC-B40 S502UC-B50 S502UC-B63 Tripping characteristic B Catalog number 6 10 13 16 20 25 32 40 50 63 6 10 13 16 20 25 32 40 50 63 3 4 S503UC-B6 S503UC-B10 S503UC-B13 S503UC-B16 S503UC-B20 S503UC-B25 S503UC-B32 S503UC-B40 S503UC-B50 S503UC-B63 S504UC-B6 S504UC-B10 S504UC-B13 S504UC-B16 S504UC-B20 S504UC-B25 S504UC-B32 S504UC-B40 S504UC-B50 S504UC-B63 10,000 UL 1077 IEC 250 VDC per pole (600 VDC 4P) 30 kA 250 VDC per pole (750 VDC 4P) 30 kA 5000 1000 500 S502UC-B Inductive loads 100 50 • B Curve • Designed for allowing higher in-rush currents during system start up • Example: motors, transformers 10 5 Accessories & technical data seconds Accessories – See page 15.71 Technical data – See page 15.76 - 82 S503UC-B Rated current s 1 0.5 DC 0.1 0.05 15 0.01 1 2 3 5 7 10 20 30 multiple of rated current S504UC-B Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com re s tu ker a i in ea M it br 0 cu S50 cir K S500UC-K, 250 VDC per pole (600 VDC 4P) UL/IEC (750 VDC 4P) Supplemental protectors, UL1077, CSA 22.2, IEC No. of poles 1 S501UC-K S502UC-K 2 S503UC-K Rated current 0.1 – 0.15 0.14 – 0.21 0.2 – 0.3 0.28 – 0.42 0.38 – 0.58 0.53 – 0.8 0.73 – 1.1 1 – 1.5 1.4 – 2.1 2 – 3 2.8 – 4.2 3.8 – 5.8 5.3 – 8 7.3 – 11 10 – 15 14 – 20 18 – 26 23 – 32 29 – 37 34 – 41 38 – 45 0.1 – 0.15 0.14 – 0.21 0.2 – 0.3 0.28 – 0.42 0.38 – 0.58 0.53 – 0.8 0.73 – 1.1 1 – 1.5 1.4 – 2.1 2 – 3 2.8 – 4.2 3.8 – 5.8 5.3 – 8 7.3 – 11 10 – 15 14 – 20 18 – 26 23 – 32 29 – 37 34 – 41 38 – 45 Catalog number S501UC-K0.15 S501UC-K0.21 S501UC-K0.3 S501UC-K0.42 S501UC-K0.58 S501UC-K0.8 S501UC-K1.1 S501UC-K1.5 S501UC-K2.1 S501UC-K3 S501UC-K4.2 S501UC-K5.8 S501UC-K8 S501UC-K11 S501UC-K15 S501UC-K20 S501UC-K26 S501UC-K32 S501UC-K37 S501UC-K41 S501UC-K45 S502UC-K0.15 S502UC-K0.21 S502UC-K0.3 S502UC-K0.42 S502UC-K0.58 S502UC-K0.8 S502UC-K1.1 S502UC-K1.5 S502UC-K2.1 S502UC-K3 S502UC-K4.2 S502UC-K5.8 S502UC-K8 S502UC-K11 S502UC-K15 S502UC-K20 S502UC-K26 S502UC-K32 S502UC-K37 S502UC-K41 S502UC-K45 Tripping characteristic K 15 S504UC-K No. of poles Rated current Catalog number 0.1 – 0.15 0.14 – 0.21 0.2 – 0.3 0.28 – 0.42 0.38 – 0.58 0.53 – 0.8 0.73 – 1.1 1 – 1.5 1.4 – 2.1 2 – 3 2.8 – 4.2 3.8 – 5.8 5.3 – 8 7.3 – 11 10 – 15 14 – 20 18 – 26 23 – 32 29 – 37 34 – 41 38 – 45 0.1 – 0.15 0.14 – 0.21 0.2 – 0.3 0.28 – 0.42 0.38 – 0.58 0.53 – 0.8 0.73 – 1.1 1 – 1.5 1.4 – 2.1 2 – 3 2.8 – 4.2 3.8 – 5.8 5.3 – 8 7.3 – 11 10 – 15 14 – 20 18 – 26 23 – 32 29 – 37 34 – 41 38 – 45 3 4 S503UC-K0.15 S503UC-K0.21 S503UC-K0.3 S503UC-K0.42 S503UC-K0.58 S503UC-K0.8 S503UC-K1.1 S503UC-K1.5 S503UC-K2.1 S503UC-K3 S503UC-K4.2 S503UC-K5.8 S503UC-K8 S503UC-K11 S503UC-K15 S503UC-K20 S503UC-K26 S503UC-K32 S503UC-K37 S503UC-K41 S503UC-K45 S504UC-K0.15 S504UC-K0.21 S504UC-K0.3 S504UC-K0.42 S504UC-K0.58 S504UC-K0.8 S504UC-K1.1 S504UC-K1.5 S504UC-K2.1 S504UC-K3 S504UC-K4.2 S504UC-K5.8 S504UC-K8 S504UC-K11 S504UC-K15 S504UC-K20 S504UC-K26 S504UC-K32 S504UC-K37 S504UC-K41 S504UC-K45 10,000 UL 1077 IEC 250 VDC per pole (600 VDC 4P) 30 kA 250 VDC per pole (750 VDC 4P) 30 kA 5000 1000 500 Inductive loads • K Curve • Designed for allowing higher in-rush currents during system start up • Example: motors, transformers 100 50 10 5 Accessories & technical data seconds Accessories – See page 15.71 Technical data – See page 15.76 - 82 1 0.5 0.1 0.05 DC 0.01 1 2 3 5 10 20 30 multiple of rated current Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com cir Min cu ia it b tur S5 rea e 00 ke r Accessories S500 UL1077 s Auxiliary contacts The auxiliary contacts will signal whether the breaker is in the ON or OFF position. Description For field mounting: left side 1 N.O./1 N.C. 2 N.O. Catalog number S500-H11 S500-H20 S500-H11, -H20 Bell alarm The bell alarm includes a set of contacts that will only signal when the breaker has tripped. Typically the contacts would be connected to an alarm or bell to signal the operator that an overcurrent trip has occurred. The bell alarm also includes a test button for testing the alarm contacts without opening the breaker. Description For field mounting: left side 1 N.O./1 N.C. 2 N.O. Catalog number S500-S11 S500-S20 S500-S11, -S20 Handle mechanism Description Handle mechanism Catalog number S500-RD3 For use with 1-4 pole S500 MCBs and disconnect switch selector handles with 5mm shafts. S500-RD3 Power feed terminal - Accepts into 2/0 AWG Description Rear mount terminal S500-K1 Catalog number S500-K2 Rear mount terminal - Accepts into 2/0 AWG Description Accepts 4AWG/25mm Catalog number S500-K1 Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com 15 re s tu ker a i in ea M it br 0 cu S50 cir Technical data S500-K & S500UC-B, K Technical data Approvals UL CSA Number of poles Tripping characteristic Rated currents Rated voltage Frequency Mounting position Standard mounting Clamps only for CU Service life, mechanical at rated load Ambient temperature S500-K S500UC-B, K 1077 C22.2 - No. 235 1, 2, 3 K 0.1 to 45 A 480Y/277 VAC, 600Y/346 VAC 50/60 Hz vertical, horizontal 35mm DIN rail 16 - 4 AWG 20,000 40°C... 104°F 1077 C22.2 - No. 235 1, 2, 3, 4 B, K B: 6 - 63 A; K: 0.15 - 45 A 250 VDC per pole (600 VDC 4 pole) 50/60 Hz vertical, horizontal 35mm DIN rail 16 - 4 AWG 20,000 40°C... 104°F Tripping characteristic K 10,000 5000 5000 1000 500 1000 500 100 50 100 50 10 5 10 5 1 0.5 1 0.5 seconds 10,000 seconds 15 Tripping characteristic B AC 0.1 0.05 0.1 0.05 DC DC 0.01 0.01 1 2 3 5 8 10 12 multiple of rated current 20 30 1 2 3 5 7 10 20 30 multiple of rated current Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com cir Min cu ia it b tur S5 rea e 00 ke r Approximate dimensions S500 & Accessories s S500 2.95 75 1.97 50 0.98 25 3.64 92.5 1.73 44 3.15 3.62 1.77 45 80 92 CL 2.22 2.95 75 56.5 1.14 29 0.24 6 S500 S500-H11, S500-H20 S500-S11, S500-S20 S500-RD3 Handle mechanism 92 80 56.5 45 75 91 6 35 12.5 15 3.15 80 1.60 40.7 S500 handle mechanism S500 Front mounting kit CL 4.41 2.91 112 74 2.00 51 0.24 D CUT-OUT 6D CL 1.81 46 "L" L + 0.51 13 L L + 1.02 26 3.31 84 0.31 8 S500 FRONT MOUNT Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com Miniature circuit breakers Technical data Miniature circuit breakers Technical data S201UP-K S201UP-K S201-B S201P-Z S201PR-K0.2 cir Min c Te uit iatu ch br re nic ea al ker da s ta S201UDC-K1 S501-K S801U-B S200 UL489 S200U-K................................................. 15.90 S200U-Z................................................. 15.90 S200UP-K............................................... 15.90 S200UP-Z............................................... 15.90 SU200PR-K............................................ 15.91 S200UDC-K............................................ 15.91 S200UDC-Z............................................ 15.91 UL1077 S200-B.................................................... 15.92 S200-C, D............................................... 15.92 S200-K.................................................... 15.92 S200-Z.................................................... 15.92 S200P-B................................................. 15.93 S200P-C................................................. 15.93 S200P-D................................................. 15.93 S200P-K................................................. 15.93 S200P-Z.................................................. 15.94 S200PR-K............................................... 15.94 S280UC-K............................................... 15.94 S280UC-Z............................................... 15.94 S800 UL489 S800U-K, Z............................................. 15.95 IEC S800S-B................................................. 15.95 S800S-C................................................. 15.95 S800S-D................................................. 15.95 S800S-K................................................. 15.96 S500 UL1077 S500-K.................................................... 15.97 S500UC-B, K.......................................... 15.97 Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com 15 re s tu ker a i in ea ta M it br l da a cu ic cir echn T Item Approvals: UL CSA VDE IEC Number of Poles: Tripping Characteristic: Rated Currents: Minimum Operating Voltage: UL/CSA Rated Voltage & Interrupting Capacity: Frequency: 120VAC 240 VAC 277 VAC 277/480 VAC 60VDC 125VDC 250VDC 500VDC IEC Rated Voltage Frequency: Rated Voltage IEC Single Pole IEC Multi-Pole Production Category: Depth of Unit Per DIN 43880: Mounting Position: Standard Mounting: Main and Shunt Trip Terminals: Wire Size Torque Tool Accessory Terminals Wire Size Torque Tool Service Life at Rated Load: Ambient Temperatures: Minimum Maximum Storage Temperatures: Minimum Maximum Shock Resistance: 15 Vibration Resistance: Disconnecting Neutral Rating: Technical data S200U-K, S200U-Z, S200UP-K, S200UP-Z S200U-K S200U-Z S200UP-K S200UP-Z 489 C22.2 No. 5 0660 898, 60947-2 1,2,3,4 K 0.2 to 63A 12V 489 C22.2 No. 5 0660 898, 60947-2 1,2,3,4 Z 0.2 to 63A 12V 489 C22.2 No. 5 0660 898, 60947-2 1,2,3,4 K 0.2 to 25A 12V 489 C22.2 No. 5 0660 898 1,2,3,4 Z 0.2 to 25A 12V 50/60 Hz 10kA 10kA — — 15kA 15kA — — 50/60 Hz 10kA 10kA — — 15kA 15kA — — 50/60 Hz 10kA 10kA 10kA 10kA 15kA 15kA — — 50/60 Hz 10kA 10kA 10kA 10kA 15kA 15kA — — 50/60 Hz 50/60 Hz 50/60 Hz 50/60 Hz 240/415VAC, 220VDC 415VAC, 440VDC IP20 68mm/ 2.68 in. Vertical / horizontal 35mm DIN rail 240/415VAC, 60VDC 415VAC, 110VDC IP20 68mm/ 2.68 in. Vertical / horizontal 35mm DIN rail 240/415VAC, 220VDC 415VAC, 440VDC IP20 68mm/ 2.68 in. Vertical / horizontal 35mm DIN rail 240/415VAC, 220VDC 415VAC, 440VDC IP20 68mm/ 2.68 in. Vertical / horizontal 35mm DIN rail 18-4 AWG/.82-21.2mm² 17.5 in-lbs. / 1.978 Nm # 2 Posidrive 18-4 AWG/.82-21.2mm² 17.5 in-lbs. / 1.978 Nm # 2 Posidrive 18-4 AWG/.82-21.2mm² 17.5 in-lbs. / 1.978 Nm # 2 Posidrive 18-4 AWG/.82-21.2mm² 17.5 in-lbs. / 1.978 Nm # 2 Posidrive 18-16 AWG/.82-1.3mm² 4.5 in-lbs./.51nm # 1 Posidrive No Load 20,000 operations 18-16 AWG/.82-1.3mm² 4.5 in-lbs./.51nm # 1 Posidrive No Load 20,000 operations Full Load 10,000 operations 18-16 AWG/.82-1.3mm² 4.5 in-lbs./.51nm # 1 Posidrive No Load 20,000 operations Full Load 10,000 operations 18-16 AWG/.82-1.3mm² 4.5 in-lbs./.51nm # 1 Posidrive No Load 20,000 operations Full Load 10,000 operations -25ºC... -13ºF 70ºC... 158ºF -25ºC... -13ºF 70ºC... 158ºF -25ºC... -13ºF 70ºC... 158ºF -25ºC... -13ºF 70ºC... 158ºF -40ºC... -40ºF 70ºC... 158ºF 30g minimum of 2 impacts, shock duration of 13ms 5g, 20 cycles, 5 Hz, 150 Hz -40ºC... -40ºF 70ºC... 158ºF 30g minimum of 2 impacts, shock duration of 13ms 5g, 20 cycles, 5 Hz, 150 Hz — — -40ºC... -40ºF 70ºC... 158ºF 30g minimum of 2 impacts, shock duration of 13ms 5g, 20 cycles, 5 Hz, 150 Hz @ 0.8 ~ In — -40ºC... -40ºF 70ºC... 158ºF 30g minimum of 2 impacts, shock duration of 13ms 5g, 20 cycles, 5 Hz, 150 Hz @ 0.8 ~ In — Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com Technical data SU200PR-K, S200UDC-K, S200UDC-Z Item Approvals: UL CSA VDE IEC Number of Poles: Tripping Characteristic: Rated Currents: Minimum Operating Voltage: UL/CSA Rated Voltage & Interrupting Capacity: Frequency: 120VAC 240 VAC 277 VAC 277/480 VAC 60VDC 125VDC 250VDC 500VDC IEC Rated Voltage Frequency: Rated Voltage IEC Single Pole IEC Multi-Pole Production Category: Depth of Unit Per DIN 43880: Mounting Position: Standard Mounting: Main and Shunt Trip Terminals: Wire Size Torque Tool Accessory Terminals Wire Size Torque Tool Service Life at Rated Load: Ambient Temperatures: Minimum Maximum Storage Temperatures: Minimum Maximum Shock Resistance: Vibration Resistance: Disconnecting Neutral Rating: SU200PR-K S200UDC-K S200UDC-Z 489 CS22.2 No. 5 0660 60947-2 1,2,3,4 K 0.2 to 63A 12 VAC 489 — 0660 — 1, 2 K 1 to 63A — 489 — 0660 — 1, 2 Z 1 to 63A — 50/60 Hz 10 kA 10 kA 10 kA 10 kA — — — — 50/60 Hz — — — — 14 kA — — — 50/60 Hz — — — — 14 kA — — — 50/60 Hz 50/60 Hz 50/60 Hz 240 VAC 400 VAC IP20 68mm/ 2.68 in. Any 35mm DIN rail — — IP20 68mm/ 2.68 in. Vertical / horizontal 35mm DIN rail — — IP20 68mm/ 2.68 in. Vertical / horizontal 35mm DIN rail 18-4 AWG/.82-21.2 mm² 25 in-lbs. / 2.8 Nm # 2 Posidrive 18-4 AWG/.82-21.2 mm² 17.5 in-lbs. / 1.978 Nm # 2 Posidrive 18-4 AWG/.82-21.2 mm² 17.5 in-lbs. / 1.978 Nm # 2 Posidrive 18-16 AWG/.82-1.3mm2 4.5 in-lbs. / .51 Nm # 1 Posidrive 6000 operations (AC), 1 cycle (1s-ON, 9s-OFF) 18-16 AWG/.82-1.3mm2 4.5 in-lbs. / .51 Nm # 1 Posidrive 18-16 AWG/.82-1.3mm2 4.5 in-lbs. / .51 Nm # 1 Posidrive Full Load 10,000 operations Full Load 10,000 operations -25ºC... -13ºF 55ºC -25ºC... -13ºF 70ºC... 158ºF -25ºC... -13ºF 70ºC... 158ºF -40ºC... -40ºF 70ºC... 158ºF 25g minimum of 2 impacts, shock duration of 13 ms 5g, 20 cycles, 5-150, 5Hz with load 0.8in — -40ºC... -40ºF 70ºC... 158ºF 30g minimum of 2 impacts, shock duration of 13 ms 5g, 20 cycles, 5 Hz, 150 Hz -40ºC... -40ºF 70ºC... 158ºF 30g minimum of 2 impacts, shock duration of 13 ms 5g, 20 cycles, 5 Hz, 150 Hz — — cir Min c Te uit iatu ch br re nic ea al ker da s ta Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com 15 re s tu ker a i in ea ta M it br l da a cu ic cir echn T 15 Technical data S200-B; S200-C, D; S200-K; S200-Z Item S200-B Approvals: UL 1077 CSA C22.2 No. 235 VDE 0641, 0660 IEC 898, 60947-2 Number of Poles: 1,2,3,4, 1+N, 3+N Tripping Characteristic: B Rated Currents: 6 to 63A Minimum Operating Voltage: 12VAC Single pole Multi pole UL/CSA Rated Voltage & Interrupting Capacity: Frequency: 50/60 Hz 120VAC 10 kA — 240 VAC 6 kA 10 kA 6 kA — 277 VAC 277/480 VAC — 6 kA 60VDC 10 kA 10 kA 10 kA 10 kA 125VDC 250VDC — — 500VDC — — IEC Rated Voltage Frequency: 50/60 Hz Rated Voltage IEC Single Pole 240/415 VAC, 60 VDC IEC Multi-Pole 415 VAC, 110 VDC Production Category: IP20 Depth of Unit Per DIN 43880: 68mm/ 2.68 in. Mounting Position: Vertical / horizontal Standard Mounting: 35mm DIN rail Main and Shunt Trip Terminals: Wire Size 18-4 AWG/.82-21.2 mm² Torque 17.5 in-lbs. / 1.978 Nm Tool # 2 Posidrive Accessory Terminals Wire Size 18-16 AWG/.82-1.3 mm² Torque 4.5 in-lbs./.51 Nm Tool # 1 Posidrive Service Life at Rated Load: No Load 20,000 operations Full Load 10,000 operations Ambient Temperatures: Minimum -25ºC... -13ºF Maximum 70ºC... 158ºF Storage Temperatures: Minimum -40ºC... -40ºF Maximum 70ºC... 158ºF Shock Resistance: 30g minimum of 2 impacts, shock duration of 13 ms Vibration Resistance: 5g, 20 cycles, 5 Hz, 150 Hz Disconnecting Neutral Rating: 6 kA switching S200-C, D 1077 C22.2 No. 235 0660 898, 60947-2 1,2,3, 1+N, 3+N C, D 0.5 to 63A 12VAC Single pole Multi pole 50/60 Hz 10 kA — 6 kA 10 kA 6 kA — — 6 kA 10 kA 10 kA 10 kA 10 kA — — — — S200-K 1077 C22.2 No. 235 0660 898, 60947-2 1,2,3,4, 1+N, 3+N K 0.5 to 63A 12 V Single pole Multi pole 50/60 Hz 10 kA — 6 kA 10 kA 6 kA — — 6 kA 10 kA 10 kA 10 kA 10 kA — — — — S200-Z 1077 C22.2 No. 235 0660 898, 60947-2 1,2,3,4, 1+N, 3+N K 0.5 to 63A 12 V Single pole Multi pole 50/60 Hz 10 kA — 6 kA 10 kA 6 kA — — 6 kA 10 kA 10 kA 10 kA 10 kA — — — — 50/60 Hz 50/60 Hz 50/60 Hz 240/415 VAC, 60 VDC 415 VAC, 110 VDC IP20 68mm/ 2.68 in. Vertical / horizontal 35mm DIN rail 240/415 VAC, 60 VDC 415 VAC, 110 VDC IP20 68mm/ 2.68 in. Vertical / horizontal 35mm DIN rail 240/415 VAC, 60 VDC 415 VAC, 110 VDC IP20 68mm/ 2.68 in. Vertical / horizontal 35mm DIN rail 18-4 AWG/.82-21.2 mm² 17.5 in-lbs. / 1.978 Nm # 2 Posidrive 18-4 AWG/.82-21.2 mm² 17.5 in-lbs. / 1.978 Nm # 2 Posidrive 18-4 AWG/.82-21.2 mm² 17.5 in-lbs. / 1.978 Nm # 2 Posidrive 18-16 AWG/.82-1.3 mm² 4.5 in-lbs./.51 Nm # 1 Posidrive No Load 20,000 operations Full Load 10,000 operations 18-16 AWG/.82-1.3 mm² 4.5 in-lbs./.51 Nm # 1 Posidrive No Load 20,000 operations Full Load 10,000 operations 18-16 AWG/.82-1.3 mm² 4.5 in-lbs./.51 Nm # 1 Posidrive No Load 20,000 operations Full Load 10,000 operations -25ºC... -13ºF 70ºC... 158ºF -25ºC... -13ºF 70ºC... 158ºF -25ºC... -13ºF 70ºC... 158ºF -40ºC... -40ºF 70ºC... 158ºF 30g minimum of 2 impacts, shock duration of 13 ms 5g, 20 cycles, 5 Hz, 150 Hz 6 kA switching -40ºC... -40ºF 70ºC... 158ºF 30g minimum of 2 impacts, shock duration of 13 ms 5g, 20 cycles, 5 Hz, 150 Hz 6 kA switching -40ºC... -40ºF 70ºC... 158ºF 30g minimum of 2 impacts, shock duration of 13 ms 5g, 20 cycles, 5 Hz, 150 Hz 6 kA switching Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com cir Min c Te uit iatu ch br re nic ea al ker da s ta Technical data S200-P-B; S200P-C; S200P-D; S200P-K Item Approvals: UL CSA VDE IEC Number of Poles: Tripping Characteristic: Rated Currents: Minimum Operating Voltage: UL/CSA Rated Voltage & Interrupting Capacity: Frequency: 120VAC 240 VAC 277 VAC 277/480 VAC 60VDC 125VDC 250VDC 500VDC IEC Rated Voltage Frequency: Rated Voltage IEC Single Pole IEC Multi-Pole Production Category: Depth of Unit Per DIN 43880: Mounting Position: Standard Mounting: Main and Shunt Trip Terminals: Wire Size Torque Tool Accessory Terminals Wire Size Torque Tool Service Life at Rated Load: Ambient Temperatures: Minimum Maximum Storage Temperatures: Minimum Maximum Shock Resistance: Vibration Resistance: Disconnecting Neutral Rating: S200P-B 1077 C22.2 No. 235 0660 898, 60947-2 1,2,3,4, 1+N, 3+N K 0.5 to 63A 12 V Single pole Multi pole 50/60 Hz 10 kA — 6 kA 10 kA 6 kA — — 6 kA 10 kA 10 kA 10 kA 10 kA — — — — S200P-C 1077 C22.2 No. 235 0660 898, 60947-2 1,2,3,4, 1+N, 3+N K 0.5 to 63A 12 V Single pole Multi pole 50/60 Hz 10 kA — 6 kA 10 kA 6 kA — — 6 kA 10 kA 10 kA 10 kA 10 kA — — — — S200P-D 1077 C22.2 No. 235 0660 898, 60947-2 1,2,3,4, 1+N, 3+N K 0.5 to 63A 12 V Single pole Multi pole 50/60 Hz 10 kA — 6 kA 10 kA 6 kA — — 6 kA 10 kA 10 kA 10 kA 10 kA — — — — S200P-K 1077 — 0660 898, 60947-2 1,2,3,4, 1+N, 3+N K 0.2 to 63A 12 V Single pole Multi pole 50/60 Hz 10 kA — 10 kA 10 kA 10 kA — — 10 kA 15 kA 15 kA 15 kA 15 kA — — — — 50/60 Hz 50/60 Hz 50/60 Hz 50/60 Hz 240/415 VAC, 60 VDC 415 VAC, 110 VDC IP20 68mm/ 2.68 in. Vertical / horizontal 35mm DIN rail 240/415 VAC, 60 VDC 415 VAC, 110 VDC IP20 68mm/ 2.68 in. Vertical / horizontal 35mm DIN rail 240/415 VAC, 60 VDC 415 VAC, 110 VDC IP20 68mm/ 2.68 in. Vertical / horizontal 35mm DIN rail 240/415 VAC, 60 VDC 415 VAC, 110 VDC IP20 68mm/ 2.68 in. Vertical / horizontal 35mm DIN rail 18-4 AWG/.82-21.2 mm² 17.5 in-lbs. / 1.978 Nm # 2 Posidrive 18-4 AWG/.82-21.2 mm² 17.5 in-lbs. / 1.978 Nm # 2 Posidrive 18-4 AWG/.82-21.2 mm² 17.5 in-lbs. / 1.978 Nm # 2 Posidrive 18-4 AWG/.82-21.2 mm² 17.5 in-lbs. / 1.978 Nm # 2 Posidrive 18-16 AWG/.82-1.3 mm² 4.5 in-lbs./.51 Nm # 1 Posidrive No Load 20,000 operations Full Load 10,000 operations 18-16 AWG/.82-1.3 mm² 4.5 in-lbs./.51 Nm # 1 Posidrive No Load 20,000 operations Full Load 10,000 operations 18-16 AWG/.82-1.3 mm² 4.5 in-lbs./.51 Nm # 1 Posidrive No Load 20,000 operations Full Load 10,000 operations 18-16 AWG/.82-1.3 mm² 4.5 in-lbs./.51 Nm # 1 Posidrive No Load 20,000 operations Full Load 10,000 operations -25ºC... -13ºF 70ºC... 158ºF -25ºC... -13ºF 70ºC... 158ºF -25ºC... -13ºF 70ºC... 158ºF -25ºC... -13ºF 70ºC... 158ºF -40ºC... -40ºF 70ºC... 158ºF 30g minimum of 2 impacts, shock duration of 13 ms 5g, 20 cycles, 5 Hz, 150 Hz 6 kA switching -40ºC... -40ºF 70ºC... 158ºF 30g minimum of 2 impacts, shock duration of 13 ms 5g, 20 cycles, 5 Hz, 150 Hz 6 kA switching -40ºC... -40ºF 70ºC... 158ºF 30g minimum of 2 impacts, shock duration of 13 ms 5g, 20 cycles, 5 Hz, 150 Hz 6 kA switching -40ºC... -40ºF 70ºC... 158ºF 30g minimum of 2 impacts, shock duration of 13 ms 5g, 20 cycles, 5 Hz, 150 Hz — Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com 15 re s tu ker a i in ea ta M it br l da a cu ic cir echn T Technical data S200P-Z; S200PR-K; S280UC-K; S280C-Z S200P-Z Item Approvals: UL CSA VDE IEC Number of Poles: Tripping Characteristic: Rated Currents: Minimum Operating Voltage: UL/CSA Rated Voltage & Interrupting Capacity: Frequency: 120VAC 240 VAC 277 VAC 277/480 VAC 60VDC 125VDC 250VDC 500VDC IEC Rated Voltage Frequency: Rated Voltage IEC Single Pole IEC Multi-Pole Production Category: Depth of Unit Per DIN 43880: Mounting Position: Standard Mounting: Main and Shunt Trip Terminals: Wire Size Torque Tool Accessory Terminals Wire Size Torque Tool Service Life at Rated Load: 15 Ambient Temperatures: Minimum Maximum Storage Temperatures: Minimum Maximum Shock Resistance: Vibration Resistance: Disconnecting Neutral Rating: 1077 — 0660 898, 60947-2 1,2,3,4 Z 0.5 to 63A 12 V Single pole Multi pole S280UC-K S200PR-K 489 CS22.2 No. 5 0660 60947-2 1,2,3,4 K 0.2 to 63A 12 VAC 50/60 Hz 10 kA — 10 kA 10 kA 10 kA — — — 50/60 Hz 10 kA 10 kA 10 kA 10 kA 15 kA 15 kA 15 kA 15 kA — — — — — — — — 1077 22.2, No. 235 0660 898, 60947-2 1,2,3 K 0.2 to 63A 12 V Single pole Multi pole 50/60 Hz 10 kA 10 kA 10 kA 6 kA 10 kA 6 kA 4.5 kA for 0.2-40 A — 5 kA for 50-63 A 10 kA 10 kA 10 kA — 4.5 kA 4.5 kA — 4.5 kA S280UC-Z 1077 22.2, No. 235 0660 898, 60947-2 1,2,3 Z 0.5 to 63A 12 V Single pole Multi pole 50/60 Hz 10 kA — 10 kA 10 kA 10 kA — — 4.5 kA for 0.2-40 A 5 kA for 50-63 A 10 kA 10 kA 10 kA 10 kA 4.5 kA 4.5 kA — 4.5 kA 50/60 Hz 50/60 Hz 50/60 Hz 50/60 Hz 240/415 VAC, 220 VDC 415 VAC, 440 VDC IP20 68mm/ 2.68 in. Vertical / horizontal 35mm DIN rail 240 VAC 400 VAC IP20 68mm/ 2.68 in. Any 35mm DIN rail 240/415VAC, 220VDC 415VAC, 440VDC IP20 68mm/ 2.68 in. Vertical / horizontal 35mm DIN rail 240/415VAC, 220VDC 415VAC, 440VDC IP20 68mm/ 2.68 in. Vertical / horizontal 35mm DIN rail 18-4 AWG/.82-21.2 mm² 18-4 AWG/.82-21.2 mm² 17.5 in-lbs. / 1.978 Nm # 2 Posidrive 25 in-lbs. / 2.8 Nm # 2 Posidrive 18-4 AWG/.82-21.2 mm² for 0.2 - 40A 18-2 AWG for 50 A & above 17.5 in-lbs. / 1.978 Nm # 2 Posidrive 18-4 AWG/.82-21.2 mm² for 0.5 - 40A 18-2 AWG for 50 A & above 17.5 in-lbs. / 1.978 Nm # 2 Posidrive 18-16 AWG/.82-1.3 mm² 4.5 in-lbs./.51 Nm # 1 Posidrive No Load 20,000 operations Full Load 10,000 operations 18-16 AWG/.82-1.3 mm² 4.5 in-lbs./.51 Nm # 1 Posidrive 6000 operations (AC), 1 cycle (1s-ON, 9s-OFF) 18-16 AWG/.82-1.3 mm² 4.5 in-lbs./.51 Nm # 1 Posidrive No Load 20,000 operations Full Load 10,000 operations 18-16 AWG/.82-1.3 mm² 4.5 in-lbs./.51 Nm # 1 Posidrive No Load 20,000 operations Full Load 10,000 operations -25ºC... -13ºF 70ºC... 158ºF -25ºC... -13ºF 55ºC -25ºC... -13ºF 70ºC... 158ºF -25ºC... -13ºF 70ºC... 158ºF -40ºC... -40ºF 70ºC... 158ºF 30g minimum of 2 impacts, shock duration of 13 ms 5g, 20 cycles, 5 Hz, 150 Hz -40ºC... -40ºF 70ºC... 158ºF 25gminimum of 2 impacts, shock duration of 13 ms 5g, 20 cycles, 5-150, 5Hz with load 0.8in — -40ºC... -40ºF 70ºC... 158ºF 30g minimum of 2 impacts, shock duration of 13 ms 5g, 20 cycles, 5 Hz, 150 Hz -40ºC... -40ºF 70ºC... 158ºF 30g minimum of 2 impacts, shock duration of 13 ms 5g, 20 cycles, 5 Hz, 150 Hz — — — Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com Technical data S800U-K, Z; S800S-B, S800S-C, S800S-D Item Approvals: UL CSA VDE IEC Number of Poles: Tripping Characteristic: Rated Currents: Minimum Operating Voltage: UL/CSA Rated Voltage & Interrupting Capacity: Frequency: 120VAC 240 VAC 277 VAC 277/480 VAC 60VDC 125VDC 250VDC 500VDC IEC Rated Voltage Frequency: Rated Voltage IEC Single Pole IEC Multi-Pole Production Category: Depth of Unit Per DIN 43880: Mounting Position: Standard Mounting: Main and Shunt Trip Terminals: Wire Size Torque Tool Accessory Terminals Wire Size Torque Tool Service Life at Rated Load: Ambient Temperatures: Minimum Maximum Storage Temperatures: Minimum Maximum Shock Resistance: Vibration Resistance: Disconnecting Neutral Rating: cir Min c Te uit iatu ch br re nic ea al ker da s ta S800U-K, Z S800S-B S800S-C S800S-D 489, E312425 22.2 No. 5.1 — 60947-2 1,2,3,4 K 10 to 100A — — — — 60947-2 1,2,3,4 B 10 to 125A 400/690VAC — — — 60947-2 1,2,3,4 C 10 to 125A 400/690VAC — — — 60947-2 1,2,3,4 D 10 to 125A 400/690VAC 50/60 Hz — 50 kA multi, 30 kA single — — — — — — 50/60 Hz — 50 kA multi, 30 kA single; IEC — — — — — — 50/60 Hz — 50 kA multi, 30 kA single; IEC — — — — — — 50/60 Hz — 50 kA multi, 30 kA single; IEC — — — — — — — 50/60 Hz 50/60 Hz 50/60 Hz — — IP20 — Vertical / horizontal 35mm DIN rail 690 VAC — IP20 — Vertical / horizontal 35mm DIN rail 690 VAC — IP20 — Vertical / horizontal 35mm DIN rail 690 VAC — IP20 — Vertical / horizontal 35mm DIN rail 1... 25 35 in-lbs. / 4 Nm — 1... 25 35 in-lbs. / 4 Nm — 1... 25 35 in-lbs. / 4 Nm — 1... 25 35 in-lbs. / 4 Nm — 1... 35 35 in-lbs./4 Nm — 6,000 operations 1... 35 35 in-lbs./4 Nm — 6,000 operations 1... 35 35 in-lbs./4 Nm — 6,000 operations 1... 35 35 in-lbs./4 Nm — 6,000 operations -25ºC... -13ºF 60ºC... 140ºF -25ºC... -13ºF 60ºC... 140ºF -25ºC... -13ºF 60ºC... 140ºF -25ºC... -13ºF 60ºC... 140ºF -40ºC... -40ºF 70ºC... 158ºF — — — -40ºC... -40ºF 70ºC... 158ºF — — — -40ºC... -40ºF 70ºC... 158ºF — — — -40ºC... -40ºF 70ºC... 158ºF — — — Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com 15 re s tu ker a i in ea ta M it br l da a cu ic cir echn T Item Approvals: UL CSA VDE IEC Number of Poles: Tripping Characteristic: Rated Currents: Minimum Operating Voltage: UL/CSA Rated Voltage & Interrupting Capacity: Frequency: 120VAC 240 VAC 277 VAC 277/480 VAC 60VDC 125VDC 250VDC 500VDC IEC Rated Voltage Frequency: Rated Voltage IEC Single Pole IEC Multi-Pole Production Category: Depth of Unit Per DIN 43880: Mounting Position: Standard Mounting: Main and Shunt Trip Terminals: Wire Size Torque Tool Accessory Terminals Wire Size Torque Tool Service Life at Rated Load: Ambient Temperatures: Minimum Maximum Storage Temperatures: Minimum Maximum Shock Resistance: Vibration Resistance: Disconnecting Neutral Rating: Technical data S800S-K S800S-K — — — 60947-2 1,2,3,4 K 10 to 125A 400/690 VAC 50/60 Hz — 50 kA multi; 30 kA single; IEC — — — — — — 50/60 Hz 690 VAC — IP20 — Vertical / horizontal 35mm DIN rail 1... 25 35 in-lbs. / 4 Nm — 1... 35 35 in-lbs./4 Nm — 6,000 operations -25ºC... -13ºF 60ºC... 140ºF -40ºC... -40ºF 70ºC... 158ºF — — — 15 Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com cir Min c Te uit iatu ch br re nic ea al ker da s ta Technical data S500-K, Z; S500UC-B, K Item S500-K, Z Approvals: UL 1077 CSA C22.2 - No. 235 VDE 0641/6.78 IEC — 1,2,3, +N, +NA No. of poles: K Tripping characteristic: Rated currents: 0.1 to 45A Rated voltage: UL/CSA single pole 277VAC UL/CSA multi pole 600YVAC IEC single pole 690VAC Rated interrupting capacity: Single pole 0.15-25A – 30KA/240VAC 14KA/277VAC 26-45A – 18KA/240VAC 14KA/277VAC Multi-pole 0.15-45A – 14KA/480VAC 6KA/600VAC Frequency: 50/60Hz Mounting position: Vertical / horizontal Standard mounting: 35mm DIN rail Terminals: 16-4AWG / 1-25mm2 Service life at rated load: 20,000 operations Calibration temperature: 40°C Item S500UC-B, K Approvals: UL CSA VDE No. of poles: Tripping characteristic: Rated currents: 1077 C22.2 0660 1,2,3, 4 B, K B: 6 to 63A K: 0.15 to 45A Rated voltage: UL single pole 277VAC/250VDC UL multi pole 600VAC/600VDC 690VAC/750VDC IEC multi pole Rated interrupting capacity: B single pole: 6 – 25A 18KA/240VAC 14KA/277VAC 32 – 63A 30KA/240VAC 14KA/277VAC B two-pole: 6 – 63A 14KA/480VAC 6KA/600VAC B three-pole: 6 – 63A 14KA/480VAC 6KA/600VAC K single pole: 0.15 – 25A 30KA/240VAC 14KA/277VAC 32 – 45A 18KA/240VAC 14KA/277VAC K two-pole: 0.15 – 45A 14KA/480VAC 6KA/600VAC K three-pole: 0.5 – 45A 14KA/480VAC 6KA/600VAC 30KA/250VDC 30KA/250VDC 30KA/500VDC 30KA/600VDC 30KA/250VDC 30KA/250VDC 30KA/500VDC 30KA/600VDC Frequency: 50/60Hz Vertical / horizontal Mounting position: 35mm DIN-rail Standard mounting: Terminals: 16-4AWG / 1-25mm2 Service life at rated load: 20,000 operations Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com 15
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.6 Linearized : Yes Author : ABB Low Voltage - Clearwater Tech Create Date : 2013:05:09 09:11:20-06:00 Keywords : ABB, Miniature, Circuit, Breakers, Catalog, Distributors Modify Date : 2013:05:10 13:19:54-06:00 Has XFA : No XMP Toolkit : Adobe XMP Core 5.2-c001 63.139439, 2010/09/27-13:37:26 Metadata Date : 2013:05:10 13:19:54-06:00 Creator Tool : Adobe InDesign CS5 (7.0.4) Format : application/pdf Title : ABB Miniature Circuit Breakers Catalog Description : ABB Miniature Circuit Breaker Creator : ABB Low Voltage - Clearwater Tech Subject : ABB Miniature Circuit Breakers Catalog Distributors Document ID : uuid:b86170a2-e51b-466c-8348-37fa36ff8136 Instance ID : uuid:33d745f8-c184-4bcc-803b-f85472753aa7 Producer : Adobe PDF Library 9.9 Page Count : 96EXIF Metadata provided by EXIF.tools