Miniature circuit breakers
Index

M

ini
at
br ure
ea ci
ke rcu
rs
it

15 - Miniature circuit breakers

S200 Miniature circuit breakers...............................15.1 - 15.42
UL 489 Series
	
Ordering details
	Description...............................................................................................................15.1
	Features...................................................................................................................15.1
	
S200U-K, 240 VAC..................................................................................................15.2
	
S200U-Z, 240 VAC..................................................................................................15.3
	
S200UP-K, 480Y/277 VAC......................................................................................15.4
	
S200UP-Z, 480Y/277 VAC.......................................................................................15.5
	
SU200PR-K, 480Y/277 VAC....................................................................................15.6
	
S200UDC-K, 1 pole 60 VDC, 2 pole 125 VDC.........................................................15.7
	
S200UDC-Z, 1 pole 60 VDC, 2 pole 125 VDC..........................................................15.8
	Accessories..........................................................................................................15.9 - 15.12
	
Technical data.....................................................................................................15.13 - 15.15
	Dimensions.....................................................................................................................15.16
UL 1077 Series
	
Ordering details
	
Description & features............................................................................................15.17
	
S200-B, 480Y/277 VAC.........................................................................................15.18
	
S200-C, 480Y/277 VAC........................................................................................15.19
	
S200-D, 480Y/277 VAC.........................................................................................15.20
	
S200-K, 480Y/277 VAC.........................................................................................15.21
	
S200-Z, 480Y/277 VAC.........................................................................................15.22
	
S200P-B, 480Y/277 VAC.......................................................................................15.23
	
S200P-C, 480Y/277 VAC.......................................................................................15.24
	
S200P-D, 480Y/277 VAC.......................................................................................15.25
	
S200P-K, 480Y/277 VAC.......................................................................................15.26
	
S200P-Z, 480Y/277 VAC.......................................................................................15.27
	
S200PR-K, 240 VAC, Ring tongue.........................................................................15.28
	
S280UC-K, 500 VDC.............................................................................................15.29
	
S280UC-Z, 500 VDC.............................................................................................15.30
	Accessories........................................................................................................15.31 - 15.39
	
Technical data.....................................................................................................15.40 - 15.42
	Dimensions.........................................................................................................15.43 - 15.44

S800 Miniature circuit breakers.............................15.53 - 15.80
UL 489 Series
	
Ordering details
	
Description & features............................................................................................15.53
	
S800U-K, 240 VAC................................................................................................15.54
	
S800U-Z, 240 VAC................................................................................................15.55
	
S803W-SCL-SR UL Short circuit current limiter..........................................15.56 - 15.57
	
S800W-RSU Remote sensing unit.........................................................................15.58
IEC Series
	
Ordering details
	
Description & features............................................................................................15.59
	
S800S-B, 690 VAC................................................................................................15.60
	
S800S-C, 690 VAC................................................................................................15.61
	
S800S-D, 690 VAC................................................................................................15.62
	
S800S-K, 690 VAC................................................................................................15.63
	
UL & IEC Series
	Accessories........................................................................................................15.64 - 15.65
	
Technical data.....................................................................................................15.67 - 15.78
	Dimensions.....................................................................................................................15.79

S500 Miniature circuit breakers.............................15.81 - 15.87
	

Ordering details
	
Description & features............................................................................................15.81
	
S500-K, UL 600Y/277 VAC / IEC 690 VAC............................................................15.82
	
S500UC-B, 250 VDC per pole (600 VDC 4P).........................................................15.83
	
S500UC-K, 250 VDC per pole (600 VDC 4P).........................................................15.84
	Accessories....................................................................................................................15.85
	
Technical data.................................................................................................................15.86
	Dimensions.....................................................................................................................15.87

Technical data.........................................................15.89 - 15.97

Application guide...................................................15.45 - 15.52
Introduction, overload, short circuit, breaker definition.....................................................15.45
Circuit breaker construction................................................................................15.46 - 15.47
Circuit breaker current limitation..........................................................................15.48 - 15.49
Selective coordination and series ratings.............................................................15.50 - 15.51
Miniature circuit breaker cutaway....................................................................................15.52

Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com

15

cir Min
cu ia
it b tur
S2 rea e
00 ke
r

S200 UL 489 Series

Miniature circuit breakers

S200
UL 489 Series

s

Description

Features

The S200 Series miniature circuit breaker offers
a compact solution for protection requirements.
The S200U AND S200UP devices are UL 489
tested current limiting and DIN rail mounted.
The S200U and S200UP is available with
application-specific trip characteristics to
provide maximum circuit protection.
The breakers offer thermal-magnetic trip
protection according to K and Z characteristics.
For the worldwide market, the breakers carry
UL, CSA, IEC, CE and many other agency
approvals and certifications.

	•	
UL current limiting
	•	
Fast breaking time (2.3 – 2.5 ms)
	•	
Bus connection system
	•	
Wide range of accessories
	•	
Available with variable depth handle
mechanism
	•	
CE certified and marked
	•	
DIN rail mounting
	•	
Finger safe terminals
	•	
Multi-function terminals
	•	
Suitable for reverse feed but S200UDC has
polarity
	•	
UL 489 Listed - branch circuit protective
device. UL File #E212323

S200U
Amperage

0.2 – 63

Voltage
Poles

S200UP

SU200PR

S200UDC

0.2 – 25

0.2 – 35A ; 40 – 63A

1 – 63

240 VAC

480Y/277VAC

480Y/277 VAC ; 240 VAC

60-125 VDC

1, 2, 3, 4

1, 2, 3, 4

1, 2, 3, 4

1, 2

Trip characteristics

K, Z

K, Z

K

K, Z

Interrupting ratings

Up to 25 kA : IEC 60947-2
10 kA : UL 489
10 kA : CSA 22.2 No. 5

Up to 25 kA : IEC
60947-2
10 kA : UL 489
10 kA : CSA 22.2 No. 5

10kA: UL489
10kA: CSA 22.2 No.5

14 kA : UL489
14 kA: CSA 22.2 No. 5

Auxiliary contacts

Yes

Yes

Yes

Yes

Bell alarm

Yes

Yes

Yes

Yes

Shunt trip

Yes

Yes

Yes

Yes

Bus bar

Yes

Yes

No

Yes

Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com

15

re s
tu ker
a
i
in ea
M it br 0
cu S20
cir

K

S200U-K, 240 VAC
Branch circuit protection
UL 489, CSA 22.2 No. 5
No. of
poles

1

S201U-K

2
S202U-K

15

Rated
current

0.2
0.3
0.5
0.75
1
1.6
2
3
4
5
6
8
10
15
16
20
25
30
32
40
50
60
63
0.2
0.3
0.5
0.75
1
1.6
2
3
4
5
6
8
10
15
16
20
25
30
32
40
50
60
63

Catalog number

S201U-K0.2
S201U-K0.3
S201U-K0.5
S201U-K0.75
S201U-K1
S201U-K1.6
S201U-K2
S201U-K3
S201U-K4
S201U-K5
S201U-K6
S201U-K8
S201U-K10
S201U-K15
S201U-K16
S201U-K20
S201U-K25
S201U-K30
S201U-K32
S201U-K40
S201U-K50
S201U-K60
S201U-K63
S202U-K0.2
S202U-K0.3
S202U-K0.5
S202U-K0.75
S202U-K1
S202U-K1.6
S202U-K2
S202U-K3
S202U-K4
S202U-K5
S202U-K6
S202U-K8
S202U-K10
S202U-K15
S202U-K16
S202U-K20
S202U-K25
S202U-K30
S202U-K32
S202U-K40
S202U-K50
S202U-K60
S202U-K63

No. of
poles

3

4

Rated
current

0.2
0.3
0.5
0.75
1
1.6
2
3
4
5
6
8
10
15
16
20
25
30
32
40
50
60
63
0.2
0.3
0.5
0.75
1
1.6
2
3
4
5
6
8
10
15
16
20
25
30
32
40
50
60
63

Catalog number

S203U-K0.2
S203U-K0.3
S203U-K0.5
S203U-K0.75
S203U-K1
S203U-K1.6
S203U-K2
S203U-K3
S203U-K4
S203U-K5
S203U-K6
S203U-K8
S203U-K10
S203U-K15
S203U-K16
S203U-K20
S203U-K25
S203U-K30
S203U-K32
S203U-K40
S203U-K50
S203U-K60
S203U-K63
S204U-K0.2
S204U-K0.3
S204U-K0.5
S204U-K0.75
S204U-K1
S204U-K1.6
S204U-K2
S204U-K3
S204U-K4
S204U-K5
S204U-K6
S204U-K8
S204U-K10
S204U-K15
S204U-K16
S204U-K20
S204U-K25
S204U-K30
S204U-K32
S204U-K40
S204U-K50
S204U-K60
S204U-K63

Tripping characteristic K
UL 489
240 VAC
10 kA
S203U-K

Inductive loads
• K Curve
• Designed for allowing higher in-rush
currents during system start up
• Example: motors, transformers

Accessories & technical data

Accessories – See page 15.9 - 15.13
Technical data – See page 15.14 -15.16

S204U-K

Note: This breaker for AC use only

Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com

cir Min
cu ia
it b tur
S2 rea e
00 ke
r

S200U-Z, 240 VAC
Branch circuit protection
UL 489, CSA 22.2 No. 5

Z

No. of
poles

1

S201U-Z

2

S202U-Z

Rated
current

0.5
1
1.6
2
3
4
5
6
8
10
15
16
20
25
30
32
40
50
60
63
0.5
1
1.6
2
3
4
5
6
8
10
15
16
20
25
30
32
40
50
60
63

Catalog number

S201U-Z0.5
S201U-Z1
S201U-Z1.6
S201U-Z2
S201U-Z3
S201U-Z4
S201U-Z5
S201U-Z6
S201U-Z8
S201U-Z10
S201U-Z15
S201U-Z16
S201U-Z20
S201U-Z25
S201U-Z30
S201U-Z32
S201U-Z40
S201U-Z50
S201U-Z60
S201U-Z63
S202U-Z0.5
S202U-Z1
S202U-Z1.6
S202U-Z2
S202U-Z3
S202U-Z4
S202U-Z5
S202U-Z6
S202U-Z8
S202U-Z10
S202U-Z15
S202U-Z16
S202U-Z20
S202U-Z25
S202U-Z30
S202U-Z32
S202U-Z40
S202U-Z50
S202U-Z60
S202U-Z63

s

No. of
poles

3

4

Rated
current

0.5
1
1.6
2
3
4
5
6
8
10
15
16
20
25
30
32
40
50
60
63
0.5
1
1.6
2
3
4
5
6
8
10
15
16
20
25
30
32
40
50
60
63

Catalog number

S203U-Z0.5
S203U-Z1
S203U-Z1.6
S203U-Z2
S203U-Z3
S203U-Z4
S203U-Z5
S203U-Z6
S203U-Z8
S203U-Z10
S203U-Z15
S203U-Z16
S203U-Z20
S203U-Z25
S203U-Z30
S203U-Z32
S203U-Z40
S203U-Z50
S203U-Z60
S203U-Z63
S204U-Z0.5
S204U-Z1
S204U-Z1.6
S204U-Z2
S204U-Z3
S204U-Z4
S204U-Z5
S204U-Z6
S204U-Z8
S204U-Z10
S204U-Z15
S204U-Z16
S204U-Z20
S204U-Z25
S204U-Z30
S204U-Z32
S204U-Z40
S204U-Z50
S204U-Z60
S204U-Z63

Tripping characteristic Z
UL 489
240 VAC
10 kA

Resistive loads
• Z Curve
• Designed to provide maximum protection with
a very low short
circuit trip setting
• Example: semiconductors, control circuits
S203U-Z

Accessories & technical data

Accessories – See page 15.9 - 15.13
Technical data – See page 15.14 -15.16

S204U-Z

Note: This breaker for AC use only

Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com

15

re s
tu ker
a
i
in ea
M it br 0
cu S20
cir

K

S200UP-K, 480Y/277 VAC
Branch circuit protection
UL 489, CSA 22.2 No. 5
No. of
poles

1

S201UP-K

2

Rated
current

Catalog number

0.2
0.3
0.5
0.75
1
1.6
2
3
4
5
6
8
10
15
16
20
25
0.2
0.3
0.5
0.75
1
1.6
2
3
4
5
6
8
10
15
16
20
25

S201UP-K0.2
S201UP-K0.3
S201UP-K0.5
S201UP-K0.75
S201UP-K1
S201UP-K1.6
S201UP-K2
S201UP-K3
S201UP-K4
S201UP-K5
S201UP-K6
S201UP-K8
S201UP-K10
S201UP-K15
S201UP-K16
S201UP-K20
S201UP-K25
S202UP-K0.2
S202UP-K0.3
S202UP-K0.5
S202UP-K0.75
S202UP-K1
S202UP-K1.6
S202UP-K2
S202UP-K3
S202UP-K4
S202UP-K5
S202UP-K6
S202UP-K8
S202UP-K10
S202UP-K15
S202UP-K16
S202UP-K20
S202UP-K25

No. of
poles

3

4

Rated
current

0.2
0.3
0.5
0.75
1
1.6
2
3
4
5
6
8
10
15
16
20
25
0.2
0.3
0.5
0.75
1
1.6
2
3
4
5
6
8
10
15
16
20
25

Catalog number

S203UP-K0.2
S203UP-K0.3
S203UP-K0.5
S203UP-K0.75
S203UP-K1
S203UP-K1.6
S203UP-K2
S203UP-K3
S203UP-K4
S203UP-K5
S203UP-K6
S203UP-K8
S203UP-K10
S203UP-K15
S203UP-K16
S203UP-K20
S203UP-K25
S204UP-K0.2
S204UP-K0.3
S204UP-K0.5
S204UP-K0.75
S204UP-K1
S204UP-K1.6
S204UP-K2
S204UP-K3
S204UP-K4
S204UP-K5
S204UP-K6
S204UP-K8
S204UP-K10
S204UP-K15
S204UP-K16
S204UP-K20
S204UP-K25

Tripping characteristic K
S202UP-K

UL 489
480Y/277 VAC
10 kA

Inductive loads
• K Curve
• Designed for allowing higher in-rush currents
during system start up
• Example: motors, transformers

15

Accessories & technical data

Accessories – See page 15.9 - 15.13
Technical data – See page 15.14 -15.16

S203UP-K

S204UP-K

Note: This breaker for AC use only

Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com

cir Min
cu ia
it b tur
S2 rea e
00 ke
r

S200UP-Z, 480Y/277 VAC
Branch circuit protection
UL 489, CSA 22.2 No. 5

Z

No. of
poles

1

S201UP-Z

2

Rated
current

0.5
1
1.6
2
3
4
5
6
8
10
15
16
20
25
0.5
1
1.6
2
3
4
5
6
8
10
15
16
20
25

Catalog number

S201UP-Z0.5
S201UP-Z1
S201UP-Z1.6
S201UP-Z2
S201UP-Z3
S201UP-Z4
S201UP-Z5
S201UP-Z6
S201UP-Z8
S201UP-Z10
S201UP-Z15
S201UP-Z16
S201UP-Z20
S201UP-Z25
S202UP-Z0.5
S202UP-Z1
S202UP-Z1.6
S202UP-Z2
S202UP-Z3
S202UP-Z4
S202UP-Z5
S202UP-Z6
S202UP-Z8
S202UP-Z10
S202UP-Z15
S202UP-Z16
S202UP-Z20
S202UP-Z25

s

No. of
poles

3

4

Rated
current

0.5
1
1.6
2
3
4
5
6
8
10
15
16
20
25
0.5
1
1.6
2
3
4
5
6
8
10
15
16
20
25

Catalog number

S203UP-Z0.5
S203UP-Z1
S203UP-Z1.6
S203UP-Z2
S203UP-Z3
S203UP-Z4
S203UP-Z5
S203UP-Z6
S203UP-Z8
S203UP-Z10
S203UP-Z15
S203UP-Z16
S203UP-Z20
S203UP-Z25
S204UP-Z0.5
S204UP-Z1
S204UP-Z1.6
S204UP-Z2
S204UP-Z3
S204UP-Z4
S204UP-Z5
S204UP-Z6
S204UP-Z8
S204UP-Z10
S204UP-Z15
S204UP-Z16
S204UP-Z20
S204UP-Z25

Tripping characteristic Z
UL 489
480Y/277 VAC
10 kA

S202UP-Z

Resistive loads
• Z Curve
• Designed to provide maximum protection with
a very low short circuit trip setting
• Example: semiconductors, control circuits

Accessories & technical data

Accessories – See page 15.9 - 15.13
Technical data – See page 15.14 -15.16

S203UP-Z

S204UP-Z

Note: This breaker for AC use only

Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com

15

re s
tu ker
a
i
in ea
M it br 0
cu S20
cir

K

SU200PR-K, 480Y/277 VAC, Ring tongue
Branch circuit protection
UL489, CSA 22.2 No.5
No. of
poles

1

SU201PR-K0.2

SU202PR-K0.2

2

15

SU203PR-K0.2

Rated
current

0.2
0.3
0.5
0.75
1
1.6
2
3
4
5
6
8
10
13
15
16
20
25
30
32
35
40
50
60
63
0.2
0.3
0.5
0.75
1
1.6
2
3
4
5
6
8
10
13
15
16
20
25
30
32
35
40
50
60
63

Catalog number

SU201PR-K0.2
SU201PR-K0.3
SU201PR-K0.5
SU201PR-K0.75
SU201PR-K1
SU201PR-K1.6
SU201PR-K2
SU201PR-K3
SU201PR-K4
SU201PR-K5
SU201PR-K6
SU201PR-K8
SU201PR-K10
SU201PR-K13
SU201PR-K15
SU201PR-K16
SU201PR-K20
SU201PR-K25
SU201PR-K30
SU201PR-K32
SU201PR-K35
SU201PR-K40
SU201PR-K50
SU201PR-K60
SU201PR-K63
SU202PR-K0.2
SU202PR-K0.3
SU202PR-K0.5
SU202PR-K0.75
SU202PR-K1
SU202PR-K1.6
SU202PR-K2
SU202PR-K3
SU202PR-K4
SU202PR-K5
SU202PR-K6
SU202PR-K8
SU202PR-K10
SU202PR-K13
SU202PR-K15
SU202PR-K16
SU202PR-K20
SU202PR-K25
SU202PR-K30
SU202PR-K32
SU202PR-K35
SU202PR-K40
SU202PR-K50
SU202PR-K60
SU202PR-K63

No. of
poles

3

4

K characteristic

Rated
current

Catalog number

0.2
0.3
0.5
0.75
1
1.6
2
3
4
5
6
8
10
13
15
16
20
25
30
32
35
40
50
60
63
0.2
0.3
0.5
0.75
1
1.6
2
3
4
5
6
8
10
13
15
16
20
25
30
32
35
40
50
60
63

SU203PR-K0.2
SU203PR-K0.3
SU203PR-K0.5
SU203PR-K0.75
SU203PR-K1
SU203PR-K1.6
SU203PR-K2
SU203PR-K3
SU203PR-K4
SU203PR-K5
SU203PR-K6
SU203PR-K8
SU203PR-K10
SU203PR-K13
SU203PR-K15
SU203PR-K16
SU203PR-K20
SU203PR-K25
SU203PR-K30
SU203PR-K32
SU203PR-K35
SU203PR-K40
SU203PR-K50
SU203PR-K60
SU203PR-K63
SU204PR-K0.2
SU204PR-K0.3
SU204PR-K0.5
SU204PR-K0.75
SU204PR-K1
SU204PR-K1.6
SU204PR-K2
SU204PR-K3
SU204PR-K4
SU204PR-K5
SU204PR-K6
SU204PR-K8
SU204PR-K10
SU204PR-K13
SU204PR-K15
SU204PR-K16
SU204PR-K20
SU204PR-K25
SU204PR-K30
SU204PR-K32
SU204PR-K35
SU204PR-K40
SU204PR-K50
SU204PR-K60
SU204PR-K63

Tripping characteristic K
UL 489
480Y/277 VAC
10 kA

Inductive loads
• K Curve
• Designed for allowing higher in-rush currents
during system start up
• Example: motors, transformers

Accessories & technical data

Accessories – See page 15.9 - 15.13
Technical data – See page 15.14 -15.16
SU204PR-K0.2

Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com

cir Min
cu ia
it b tur
S2 rea e
00 ke
r

S200UDC-K, 1 pole 60 VDC, 2 pole 125 VDC
Branch circuit protection
UL 489, CSA 22.2 No. 5

K

No. of
poles

Rated
current

Catalog number

S202UDC-K1

Rated
current

1
S201UDC-K1
1.6
S201UDC-K1.6
2
S201UDC-K2
3
S201UDC-K3
4
S201UDC-K4
5
S201UDC-K5
6
S201UDC-K6
8
S201UDC-K8
10
S201UDC-K10
13
S201UDC-K13
15
S201UDC-K15
16
S201UDC-K16
20
S201UDC-K20
25
S201UDC-K25
30
S201UDC-K30
32
S201UDC-K32
40
S201UDC-K40
50
S201UDC-K50
60
S201UDC-K60
63
S201UDC-K63
NOTE: Standard UL 489 (only DC; please note polarity of device).

1

	S201UDC-K1	

No. of
poles

Tripping characteristic K

60
40

I1

I1 = 1.0 x In

I2

10

Minutes

I2 = 1.35 x In

ϑR = 25°C

1 = marginal characteristic
measured in cold status

20

Tripping time

Accessories & technical data

S202UDC-K1
S202UDC-K1.6
S202UDC-K2
S202UDC-K3
S202UDC-K4
S202UDC-K5
S202UDC-K6
S202UDC-K8
S202UDC-K10
S202UDC-K13
S202UDC-K15
S202UDC-K16
S202UDC-K20
S202UDC-K25
S202UDC-K30
S202UDC-K32
S202UDC-K40
S202UDC-K50
S202UDC-K60
S202UDC-K63

120

UL 489
480Y/277 VAC
14 kA

Inductive loads
• K Curve
• Designed for allowing higher in-rush currents
during system start up
• Example: motors, transformers

Catalog number

1
1.6
2
3
4
5
6
8
10
13
15
16
20
25
30
32
40
50
60
63

2

s

1

6
1
4
2

K

1
40
20

Accessories – See page 15.9 - 15.13
Technical data – See page 15.14 -15.16
Seconds

10
6
4
2
1
0.6
0.4

15

0.2

DC

0.1
0.06
0.04
0.02
0.01

1

1.5 2

3

4 5 6

8 10

15 20 30
14
25

Multiple of rated current

Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com

re s
tu ker
a
i
in ea
M it br 0
cu S20
cir

S200UDC-Z, 1 pole 60 VDC, 2 pole 125 VDC
Branch circuit protection
UL 489, CSA 22.2 No. 5

Z

No. of
poles

1

	S201UDC-K1	

S202UDC-K1

Rated
current

1
1.6
2
3
4
5
6
8
10
13
15
16
20
25
30
32
40
50
60
63

Catalog number

S201UDC-Z1
S201UDC-Z1.6
S201UDC-Z2
S201UDC-Z3
S201UDC-Z4
S201UDC-Z5
S201UDC-Z6
S201UDC-Z8
S201UDC-Z10
S201UDC-Z13
S201UDC-Z15
S201UDC-Z16
S201UDC-Z20
S201UDC-Z25
S201UDC-Z30
S201UDC-Z32
S201UDC-Z40
S201UDC-Z50
S201UDC-Z60
S201UDC-Z63

No. of
poles

2

NOTE: Standard UL 489 (only DC; please note polarity of device).

Rated
current

Catalog number

1
1.6
2
3
4
5
6
8
10
13
15
16
20
25
30
32
40
50
60
63

S202UDC-Z1
S202UDC-Z1.6
S202UDC-Z2
S202UDC-Z3
S202UDC-Z4
S202UDC-Z5
S202UDC-Z6
S202UDC-Z8
S202UDC-Z10
S202UDC-Z13
S202UDC-Z15
S202UDC-Z16
S202UDC-Z20
S202UDC-Z25
S202UDC-Z30
S202UDC-Z32
S202UDC-Z40
S202UDC-Z50
S202UDC-Z60
S202UDC-Z63

Z

Tripping characteristic Z
UL 489
480Y/277 VAC
14 kA

Accessories – See page 15.9 - 15.13
Technical data – See page 15.14 -15.16

Minutes
Tripping time

Accessories & technical data

Seconds

Resistive loads
• Z Curve
• Designed to provide maximum protection with
a very low short circuit trip setting
• Example: semiconductors, control circuits

marginal characteristic
measured in cold status

15

Multiple of rated current

Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com

cir Min
cu ia
it b tur
S2 rea e
00 ke
r

Accessories
	S200U, S200UP, SU200PR & S200UDC
UL 489, CSA 22.2 No. 5

s

Auxiliary contacts

The auxiliary contacts will signal whether the breaker is in the ON or OFF position.
Description

Catalog number

For field mounting: right side

S2C-H6RU

Bell alarm

The bell alarm includes a set of contacts that will only signal when the breaker has tripped.
Typically the contacts would be connected to an alarm or bell to signal the operator that an overcurrent trip
has occurred. The bell alarm also includes a test button for testing the alarm contacts without opening the
breaker.
S2C-H6RU

Description

Catalog number

For field mounting: right side

S2C-S6RU

Rotary operating mechanism
Allows “through the door” operation.
Description

Catalog number

Handle mechanism

S2C-DH

Shunt trip

For remote tripping of breaker, a shunt trip device can be added to the MCB. The solenoid device opens the
breaker after control voltage is applied.
Description
S2C-S6RU

Catalog number

For field mounting: right side
12…60 VAC/DC

S2C-A1U

For field mounting: right side
110…415 VAC

S2C-A2U

110…250 VDC

NOTE: For shafts and handles, refer to parts in the MCCB
section.

Possible mounting arrangements of MCB accessories

15

Legend

S2C-DH

Auxiliary contact
+ST+H+H+H)
+ST+S/H+S/H (H)+S/H (H)

H

Bell alarm/Auxiliary contact

S/H

Bell alarm/Auxiliary contact
used as auxiliary contact

S/H (H)

Shunt trip

ST

NOTE: Right hand mount accessories cannot be used in
conjunction with S2C-DH, Rotary operating mechanism.

S2C-A1U

Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com

re s
tu ker
a
i
in ea
M it br 0
cu S20
cir

Accessories
S200U, S200UP, S200UDC & SU200PR
UL 489, CSA 22.2 No. 5

Connection drawings

Bell alarm S2C-S6RU

Auxiliary contact S2C-H6RU

In ON and OFF position after hand operation

Auxiliary contact in ON position

Shunt trip S2C-A...U
Shunt trip
in OFF
position

S2C-A1U
S2C-A2U
In OFF position after tripping

Auxiliary contact in OFF position

Mounting
Addition of a S2C-H6RU auxiliary contact

Addition of a S2C-S6RU bell alarm contact

15

Addition of a S2C-A..U shunt trip
S200U-UP

S2C-A....U

Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com

Accessories
SU200PR
UL 489, CSA 22.2 No. 5

cir Min
cu ia
it b tur
S2 rea e
00 ke
r

s

SU200PR Accessory overview

H

Auxiliary contact S2C-H6RU

S

Signal contact S2C-S6RU

ST

Shunt trip S2C-A...U

SU200PR Instructions for use

15

Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com

re s
tu ker
a
i
in ea
M it br 0
cu S20
cir

Accessories
S200U, S200UP & S200UDC
UL 489, CSA 22.2 No. 5
UL approved busbars UL file # E250145
UL 489 busbar cannot be cut.

PS2/6/16 BP

For
use on:

Amp
rating

Number
of poles

Phases

Busbar length
(mm)

Catalog
number

S200U
S200UP
S201UDC

80

6
12
18

1
1
1

103.2
208.8
314.4

PS 1/6/16BP
PS 1/12/16BP
PS 1/18/16BP

S200U
S200UP
S201UDC

80

6
12
18

2
2
2

103.2
208.8
314.4

PS 2/6/16BP
PS 2/12/16BP
PS 2/18/16BP

S200U
S200UP
S201UDC

80

6
12
18

3
3
3

103.2
208.8
314.4

PS 3/6/16BP
PS 3/12/16BP
PS 3/18/16BP

1 Phase

2 Phase

Busbar tooth covers for BS...BP (UL 489)
Description

Covers three unused poles of busbar

Catalog number

BSK-BP

3 Phase

BSK-BP

Feeder terminals for PS...BP (UL 489)
Description

Catalog number

Terminal, insulated with pin contact

AST35/15BP

Feeder Terminal, single-pole terminal, can be mounted side by side, feed
on the pin of the busbar

SZ-ESK BP

	AST35/15BP	 SZ-ESPBP

15

Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com

cir Min
cu ia
it b tur
S2 rea e
00 ke
r

Technical data
S200U, S200UP, SU200PR & S200UDC
UL 489, CSA 22.2 No. 5
Technical data

S200U

S200UP

Specifications:
UL File-Number:
No. of poles:
Tripping characteristics:
Rated current:

UL 489, C 22.2 No. 5, IEC 60947-2
E 212323, UL, Current limiting series ratings
1, 2, 3 & 4
K, Z
0.2 (K) 0.5 (Z) ... 63 A
0.2 (K) 0.5 (Z) ... 25 A

Rated voltage:

Single pole: 240VAC
Multi pole: 240VAC

Short circuit capacity:
Frequency:
Degree of protection:
Mounting position:
Fixing:
Clamps only for Cu:
Service life, mech. and at rated
load:
Tightening torque:

Single pole: 277VAC
Multi pole: 480Y/277VAC

s

SU200PR

S200UDC

K
0.2 ... 63A
Single pole: 277VAC (<=35A);
240VAC (>35A)
Multi pole: 480Y/277VAC (<=35A);
240VAC (>35A)

IP20, IP40 in enclosure w/cover
Any

14 kA
50/60 Hz
IP 20
Vertical and horizontal
35 mm DIN rail
18-4 AWG (0.75 … 25 mm2)

20,000 operations

6000 operations (AC)
1 cycle (1s-ON, 9S-OFF)

20,000 operations

– 25 °C … + 55 °C/– 13 °F … + 131 °F

Shock resistance:

1P: 60 V DC
2P:125 V DC 1

10 kA
50/60 Hz
IP 20
Vertical and horizontal
35 mm DIN rail
18-4 AWG (0.75 … 25 mm2)

25 in. lbs (2.8 Nm)

Ambient temperature:

UL 489, VDE 0660
E212323, UL
1, 2
K, Z
1 - 63 A

30 g at least 2 impacts shock, duration 13 ms

25 g, 2 shocks - 13ms

25 in. lbs (2.8 Nm)
– 25 °C … + 55 °C/– 13 °F …
+ 131 °F
30 g at least 2 impacts shock,
duration 13 ms

Auxiliary contact S2C-H6RU and S2C-S6RU
Rated current:
Rated voltage AC / DC:
Contact:
Connection capacity mm2
Tightening torque:
Shock resistance acc. to DIN IEC 68-2-6:
Mechanical service life:

Shunt trip
Rated voltage
Max. release duration
Min. release voltage
Consumption on release
Coil resistance
Terminals
Tightening torque

10
24
1 pole double throw
18 – 14 AWG (0.75…2.5 mm2)
11 in.Ibs (1.2 Nm)
5 g, 20 frequency cycles 5...150...5 Hz at 24 VAC/DC, 5 mA auto-reclosing < 10 ms
10,000 operations

Type
AC
DC
AC
DC
AC
DC

V
V
ms
V
V
VA
VA
Ω
AWG/mm2
in.Ibs/Nm

S2C-A1U

S2C-A2U

12 ... 60
12 ... 60
< 10
7
10
40 ... 200
40 ... 200
3.7
18…6 / 0.75 – 16
18 / 2

110 ... 415
110 ... 250
< 10
55
80
55 ... 210
55 ... 110
225
18…6 / 0.75 – 16
18 / 2

1 Poles connected in series.

Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com

15

re s
tu ker
a
i
in ea
M it br 0
cu S20
cir

Technical data
S200U, S200UP, SU200PR & S200UDC
UL 489, CSA 22.2 No. 5

Internal resistance and power loss

Internal resistance per pole in mz, power loss per pole in W.

Type

Rated
current

S200U
S200UP

Device series
K

Device series
Z

Type

Rated
current

Device series
K

Device series
Z

A

mz

W

mz

W

A

mz

W

mz

W

 0.2
 0.3
 0.5

42500
20000
 6340

1.7
1.8
1.6

    –
    –
10100

–
–
2.5

 1
 1.6

1400
 625

1.4
1.6

2270
1100

2.3
2.8

 0.75
 1
 1.6

 2500
 1400
  625

1.4
1.4
1.6

    –
 2270
 1100

–
2.3
2.8

2
3
4

460
211
153

1.8
1.9
2.6

619
211
163

2.5
1.9
2.5

 2
 3
 4

  460
  211
  163

1.8
1.9
2.6

  619
  211
  163

2.5
1.9
2.6

6
8
10

67
45
19

2.4
2.9
1.9

104
55
21

3,7
3.5
2.1

 6
 8
10

   67
   45
   19

2.4
2.9
1.9

  104
   55
   21

3.7
3.5
2.1

13
16
20

–
8.2
7.3

–
2.1
2.0

–
10.9
7.3

–
2.8
2.9

13
16
20

    –
    8.2
    7.3

 –
2.1
2.9

    –
   10.9
   7.3

–
2.8
2.9

25
32
40

5.6
4.1
4.0

3.5
4.2
6.4

5.6
4.1
4.0

3.5
4.2
6.4

25
32
40

    5.6
    4.1
    4.0

3.5
4.2
6.4

   5.6
   4.1
   4.0

3.5
4.2
6.4

50
63

1.2
1.3

3.0
5.2

1.8
1.3

4.4
5.2

50
63

    1.2
    1.3

3.0
5.2

   1.8
   1.3

4.4
5.2

S200UDC

SU200PR

15

Rated current

Internal resistance per pole 1)

Power loss per pole 1)

A

mΩ

W

0.2

25300

1.01

0.3

13700

1.23

0.5

4740

1.19

0.75

2067

1.16

1

1270

1.27

1.5

610

1.56

2

442

1.77

3

140

1.26

4

109

1.75

5

50

1.26

6

54

1.94

8

22

1.41

10

18.2

1.82

13

14.8

2.50

15

8.1

1.83

16

11.1

2.83

20

8.5

3.40

25

5.5

3.43

30

3.8

3.39

32

4.6

4.70

35

3.9

4.76

40

2.8

4.40

50

1.7

4.25

60

1.7

6.18

63

1.9

7.56

	 Internal resistances and power loss are subject to application-specific and environment	 specific conditions and are therefore to be considered as typical values.
4)

Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com

cir Min
cu ia
it b tur
S2 rea e
00 ke
r

Technical data
S200U, S200UP, SU200PR & S200UDC
UL 489, CSA 22.2 No. 5
Tripping characteristic K (68 °F)

s

Tripping characteristic Z (68 °F)

Breaker calibration temperature 68°F
See chart below for temperature DeRating

Breaker calibration temperature 68°F
See chart below for temperature DeRating

Temperature derating
Max. operating current values depending on the ambient temperature for a circuit-breaker of characteristics type K and Z
K and Z
In (A)
 0.5
 1.0
 1.6
 2.0
 3.0
 4.0
 6.0
 8.0
10.0
13.0
16.0
20.0
25.0
32.0
40.0
50.0
63.0

Ambient temperature T (°C/°F)
– 40/– 40 – 30/– 22 – 20/– 4
 0.66
 1.32
 2.12
 2.65
 4.0
 5.3
 7.9
10.8
13.2
17.2
21.2
26.5
33.1
42.3
52.9
66.1
83.3

 0.64
 1.27
 2.04
 2.55
 3.8
 5.1
 7.6
10.2
12.7
16.6
20.4
25.5
31.9
40.8
51.0
63.7
80.3

 0.61
 1.22
 1.96
 2.45
 3.7
 4.9
 7.3
 9.8
12.2
15.9
19.6
24.5
30.6
39.2
49.0
61.2
77.2

– 10/14

0/32

10/50

20/68

30/86

40/104

50/122

60/140

70/158

 0.59
 1.17
 1.88
 2.35
 3.5
 4.7
 7.0
 9.4
11.7
15.2
18.8
23.5
29.3
37.5
46.9
58.6
73.9

 0.56
 1.12
 1.79
 2.24
 3.4
 4.5
 6.7
 8.9
11.2
14.5
17.9
22.4
28.0
35.8
44.7
55.9
70.4

 0.53
 1.06
 1.70
 2.12
 3.2
 4.2
 6.4
 8.5
10.6
13.8
17.0
21.2
26.5
33.9
42.4
53.0
66.8

 0.50
 1.00
 1.60
 2.00
 3.0
 4.0
 6.0
 8.0
10.0
13.0
16.0
20.0
25.0
32.0
40.0
50.0
63.0

 0.47
 0.94
 1.50
 1.87
 2.8
 3.7
 5.6
 7.5
 9.4
12.2
15.0
18.7
23.4
29.9
37.4
46.8
58.9

 0.43
 0.87
 1.39
 1.73
 2.6
 3.5
 5.2
 6.9
 8.7
11.3
13.9
17.3
21.7
27.7
34.6
43.3
54.6

 0.40
 0.79
 1.26
 1.58
 2.4
 3.2
 4.7
 6.3
 7.9
10.3
12.6
15.8
19.8
25.3
31.6
39.5
49.8

 0.35
 0.71
 1.13
 1.41
 2.1
 2.8
 4.2
 5.7
 7.1
 9.2
11.3
14.1
17.7
22.6
28.3
35.4
44.5

 0.31
 0.61
 0.98
 1.22
 1.8
 2.4
 3.7
 4.9
 6.1
 8.0
 9.8
12.2
15.3
19.6
24.5
30.6
38.6

Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com

15

re s
tu ker
a
i
in ea
M it br 0
cu S20
cir

Approximate dimensions
S200U, S200UP, S200UDC & SU200PR
UL 489, CSA 22.2 No. 5

Approximate dimensions in mm

S200UDC

S200U

SU200PR

S200UP

S2C-H6RU, S2C-S6RU	

S2C-A..U

15

Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com

Supplementary protective devices

S200 UL 1077 Series

S200
Supplementary protective
UL 1077 Series

Description
The S200 UL 1077 Series miniature
supplementary protector offers a compact
solution for protection requirements. The S200
devices are DIN rail mounted.
The S200 is available with application-specific
trip characteristics to provide maximum circuit
protection.
The supplementary protectors offer thermalmagnetic trip protection according to B, C, D, K
and Z characteristics.
For the worldwide market, the breakers carry
UL, CSA, IEC, CE and many other agency
approvals and certifications.

S200
Amperage
Voltage
Poles
Trip
characteristics

0.5 – 63 A

s

Features
	•	
Energy limiting
	•	
Fast breaking time (2.3 – 2.5 ms)
	•	
Bus connection system
	•	
Wide range of accessories
	•	
Available with variable depth handle
mechanism
	•	
CE certified and marked
	•	
DIN rail mounting
	•	
Finger safe terminals
	•	
Multi-function terminals
	•	
Suitable for reverse feed
	•	
UL1077 Recognized supplemental protective
device. UL file # E76126

S200P
0.2 – 63 A

cir Min
cu ia
it b tur
S2 rea e
devices 00 ker

S200PR
0.2 – 63A

S280UC
0.2 – 63 A

480Y/277 VAC

480Y/277 VAC

240 VAC

250/500 VDC

1, 2, 3, 4

1, 2, 3, 4

1, 2, 3, 4

1, 2, 3, 4

B, C, D, K

B, C, D, K, Z

K

K, Z

10kA: UL1077
10kA: CSA 22.2 No.235

Up to 6kA : IEC 60947-2
10kA : UL 1077
6 kA : CSA 22.2 No. 235

6 kA : IEC 60898
6 kA : UL 1077
6 kA : CSA 22.2 No. 235

Up to 25kA : IEC 60947-2
10kA : UL 1077

Auxiliary contacts

Yes

Yes

Yes

Yes

Bell alarm

Yes

Yes

Yes

Yes

Shunt trip
Undervoltage
release
Bus bar

Yes

Yes

Yes

Yes

Yes

Yes

Yes

Yes

Yes

Yes

No

Yes

Interrupting
ratings

Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com

15

re s
tu ker
a
i
in ea
M it br 0
cu S20
cir

B

S200-B, 480Y/277 VAC
Supplemental protectors
UL 1077, CSA 22.2, No. 235
No. of
poles

1

S201-B

S202-B

1
+
NA

2

Rated
current

6
10
13
16
20
25
32
40
50
63
 6
10
13
16
20
25
32
40
50
63
6
10
13
16
20
25
32
40
50
63

Catalog number

S201-B6
S201-B10
S201-B13
S201-B16
S201-B20
S201-B25
S201-B32
S201-B40
S201-B50
S201-B63
S201-B6NA
S201-B10NA
S201-B13NA
S201-B16NA
S201-B20NA
S201-B25NA
S201-B32NA
S201-B40NA
S201-B50NA
S201-B63NA
S202-B6
S202-B10
S202-B13
S202-B16
S202-B20
S202-B25
S202-B32
S202-B40
S202-B50
S202-B63

No. of
poles

3

3
+
NA

4

Rated
current

6
10
13
16
20
25
32
40
50
63
6
10
13
16
20
25
32
40
50
63
6
10
13
16
20
25
32
40
50
63

Catalog number

S203-B6
S203-B10
S203-B13
S203-B16
S203-B20
S203-B25
S203-B32
S203-B40
S203-B50
S203-B63
S203-B6NA
S203-B10NA
S203-B13NA
S203-B16NA
S203-B20NA
S203-B25NA
S203-B32NA
S203-B40NA
S203-B50NA
S203-B63NA
S204-B6
S204-B10
S204-B13
S204-B16
S204-B20
S204-B25
S204-B32
S204-B40
S204-B50
S204-B63

Tripping characteristic B
UL 1077
480Y/277VAC
6 kA
S203-B

Resistive loads
• B Curve
• Designed for use in cable protection
applications
• Example: control circuits, lighting

Accessories & technical data

Accessories – See page 15.31 - 15.34
Technical data – See page 15.35 - 15.36

15
S204-B

S201-BNA

S203-BNA

Note: Switching neutral is noted by “NA” in the catalog number.

Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com

cir Min
cu ia
it b tur
S2 rea e
00 ke
r

S200-C, 480Y/277 VAC
Supplemental protectors
UL 1077, CSA 22.2, No. 235

C

No. of
poles

1

S201-C

S202-C

1
+
NA
 

S203-C

2 

S204-C

Rated
current

  0.5
1
1.6
 2
3
4
 6
8
10
13
16
20
25
32
40
50
63
  0.5
1
1.6
2
3
4
6
8
10
13
16
20
25
32
40
50
63
  0.5
1
1.6
 2
3
4
6
8
10
13
16
20
25
32
40
50
63

Catalog number

S201-C0.5
S201-C1
S201-C1.6
S201-C2
S201-C3
S201-C4
S201-C6
S201-C8
S201-C10
S201-C13
S201-C16
S201-C20
S201-C25
S201-C32
S201-C40
S201-C50
S201-C63
S201-C0.5NA
S201-C1NA
S201-C1.6NA
S201-C2NA
S201-C3NA
S201-C4NA
S201-C6NA
S201-C8NA
S201-C10NA
S201-C13NA
S201-C16NA
S201-C20NA
S201-C25NA
S201-C32NA
S201-C40NA
S201-C50NA
S201-C63NA
S202-C0.5
S202-C1
S202-C1.6
S202-C2
S202-C3
S202-C4
S202-C6
S202-C8
S202-C10
S202-C13
S202-C16
S202-C20
S202-C25
S202-C32
S202-C40
S202-C50
S202-C63

s

No. of
poles

3
 

3
+
NA
 

4

Rated
current

  0.5
1
1.6
 2
3
4
6
8
10
13
16
20
25
32
40
50
63
0.5
1
1.6
2
3
4
6
8
10
13
16
20
25
32
40
50
63
  0.5
1
  1.6
 2
3
4
6
8
10
13
16
20
25
32
40
50
63

Catalog number

S203-C0.5
S203-C1
S203-C1.6
S203-C2
S203-C3
S203-C4
S203-C6
S203-C8
S203-C10
S203-C13
S203-C16
S203-C20
S203-C25
S203-C32
S203-C40
S203-C50
S203-C63
S203-C0.5NA
S203-C1NA
S203-C1.6NA
S203-C2NA
S203-C3NA
S203-C4NA
S203-C6NA
S203-C8NA
S203-C10NA
S203-C13NA
S203-C16NA
S203-C20NA
S203-C25NA
S203-C32NA
S203-C40NA
S203-C50NA
S203-C63NA
S204-C0.5
S204-C1
S204-C1.6
S204-C2
S204-C3
S204-C4
S204-C6
S204-C8
S204-C10
S204-C13
S204-C16
S204-C20
S204-C25
S204-C32
S204-C40
S204-C50
S204-C63

Tripping characteristic C
UL 1077
480Y/277 VAC
6 kA

Resistive loads
• C Curve
• Designed for use with medium magnetic
start up currents
• Example: lighting, control panels
S201-CNA

Accessories & technical data

Accessories – See page 15.31 - 15.34
Technical data – See page 15.35 - 15.36

S203-CNA

Note: Switching neutral is noted by “NA” in the catalog
number.

Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com

15

re s
tu ker
a
i
in ea
M it br 0
cu S20
cir

D

S200-D, 480Y/277 VAC
Supplemental protectors
UL 1077, CSA 22.2, No. 235
No. of
poles

1
S201-D

S202-D

1
+
NA
 

S203-D

2
15

S204-D

Rated
current

  0.5
1
1.6
 2
3
4
 6
8
10
13
16
20
25
32
40
50
63
  0.5
1
1.6
2
3
4
6
8
10
13
16
20
25
32
40
50
63
  0.5
1
1.6
 2
3
4
6
8
10
13
16
20
25
32
40
50
63

Catalog number

S201-D0.5
S201-D1
S201-D1.6
S201-D2
S201-D3
S201-D4
S201-D6
S201-D8
S201-D10
S201-D13
S201-D16
S201-D20
S201-D25
S201-D32
S201-D40
S201-D50
S201-D63
S201-D0.5NA
S201-D1NA
S201-D1.6NA
S201-D2NA
S201-D3NA
S201-D4NA
S201-D6NA
S201-D8NA
S201-D10NA
S201-D13NA
S201-D16NA
S201-D20NA
S201-D25NA
S201-D32NA
S201-D40NA
S201-D50NA
S201-D63NA
S202-D0.5
S202-D1
S202-D1.6
S202-D2
S202-D3
S202-D4
S202-D6
S202-D8
S202-D10
S202-D13
S202-D16
S202-D20
S202-D25
S202-D32
S202-D40
S202-D50
S202-D63

No. of
poles

3
 

3
+
NA

4

Rated
current

  0.5
1
1.6
 2
3
4
6
8
10
13
16
20
25
32
40
50
63
0.5
1
1.6
2
3
4
6
8
10
13
16
20
25
32
40
50
63
  0.5
1
  1.6
 2
3
4
6
8
10
13
16
20
25
32
40
50
63

Catalog number

S203-D0.5
S203-D1
S203-D1.6
S203-D2
S203-D3
S203-D4
S203-D6
S203-D8
S203-D10
S203-D13
S203-D16
S203-D20
S203-D25
S203-D32
S203-D40
S203-D50
S203-D63
S203-D0.5NA
S203-D1NA
S203-D1.6NA
S203-D2NA
S203-D3NA
S203-D4NA
S203-D6NA
S203-D8NA
S203-D10NA
S203-D13NA
S203-D16NA
S203-D20NA
S203-D25NA
S203-D32NA
S203-D40NA
S203-D50NA
S203-D63NA
S204-D0.5
S204-D1
S204-D1.6
S204-D2
S204-D3
S204-D4
S204-D6
S204-D8
S204-D10
S204-D13
S204-D16
S204-D20
S204-D25
S204-D32
S204-D40
S204-D50
S204-D63

Tripping characteristic D
UL 1077
480Y/277 VAC
6 kA

Inductive loads
• D Curve
• Designed for allowing higher in-rush
currents during system start up
• Example: motors, transformers
S201-DNA

Accessories & technical data

Accessories – See page 15.31 - 15.34
Technical data – See page 15.35 - 15.36

S203-DNA

Note: Switching neutral is noted by “NA” in the catalog
number.

Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com

cir Min
cu ia
it b tur
S2 rea e
00 ke
r

S200-K, 480Y/277 VAC
Supplemental protectors
UL 1077, CSA 22.2, No. 235

K

No. of
poles

1
 
 

S201-K

S202-K

1
+
NA

S203-K

2
S204-K

Rated
current

0.5
1
1.6
2
3
4
5
6
8
10
13
15
16
20
25
32
40
50
60
63
 0.5
1
1.6
2
3
4
6
 8
10
13
16
20
25
32
40
50
63
0.5
1
1.6
2
3
4
5
6
8
10
13
15
16
20
25
32
40
50
60
63

Catalog number

S201-K0.5
S201-K1
S201-K1.6
S201-K2
S201-K3
S201-K4
S201-K5
S201-K6
S201-K8
S201-K10
S201-K13
S201-K15
S201-K16
S201-K20
S201-K25
S201-K32
S201-K40
S201-K50
S201-K60
S201-K63
S201-K0.5NA
S201-K1NA
S201-K1.6NA
S201-K2NA
S201-K3NA
S201-K4NA
S201-K6NA
S201-K8NA
S201-K10NA
S201-K13NA
S201-K16NA
S201-K20NA
S201-K25NA
S201-K32NA
S201-K40NA
S201-K50NA
S201-K63NA
S202-K0.5
S202-K1
S202-K1.6
S202-K2
S202-K3
S202-K4
S202-K5
S202-K6
S202-K8
S202-K10
S202-K13
S202-K15
S202-K16
S202-K20
S202-K25
S202-K32
S202-K40
S202-K50
S202-K60
S202-K63

s

No. of
poles

3

3
+
NA
 

4

Rated
current

  0.5
 1
1.6
2
3
4
5
6
8
10
13
15
16
20
25
32
40
50
60
63
  0.5
 1
  1.6
 2
 3
4
6
8
10
13
16
20
25
32
40
50
63
0.5
 1
  1.6
 2
 3
 4
5
 6
 8
10
13
15
16
20
25
32
40
50
60
63

Catalog number

S203-K0.5
S203-K1
S203-K1.6
S203-K2
S203-K3
S203-K4
S203-K5
S203-K6
S203-K8
S203-K10
S203-K13
S203-K15
S203-K16
S203-K20
S203-K25
S203-K32
S203-K40
S203-K50
S203-K60
S203-K63
S203-K0.5NA
S203-K1NA
S203-K1.6NA
S203-K2NA
S203-K3NA
S203-K4NA
S203-K6NA
S203-K8NA
S203-K10NA
S203-K13NA
S203-K16NA
S203-K20NA
S203-K25NA
S203-K32NA
S203-K40NA
S203-K50NA
S203-K63NA
S204-K0.5
S204-K1
S204-K1.6
S204-K2
S204-K3
S204-K4
S204-K5
S204-K6
S204-K8
S204-K10
S204-K13
S204-K15
S204-K16
S204-K20
S204-K25
S204-K32
S204-K40
S204-K50
S204-K60
S204-K63

Tripping characteristic K
UL 1077
480Y/277 VAC
6 kA
S201-KNA

Inductive loads
• K Curve
• Designed for allowing higher in-rush
currents during system start up
• Example: motors, transformers

Accessories & technical data

Accessories – See page 15.31 - 15.34
Technical data – See page 15.35 - 15.36
S203-KNA

Note: Switching neutral is noted by “NA” in the catalog
number.

Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com

15

re s
tu ker
a
i
in ea
M it br 0
cu S20
cir

Z

S200-Z, 480Y/277 VAC
Supplemental protectors
UL 1077, CSA 22.2, No. 235
No. of
poles

Rated
current

1

0.5
1
1.6
2
3
4
6
10
13
16
20
25
32
40
50
63

2

0.5
1
1.6
2
3
4
6
10
13
16
20
25
32
40
50
63

S201-Z0.5

S202-Z0.5

Catalog number

S201-Z0.5
S201-Z1
S201-Z1.6
S201-Z2
S201-Z3
S201-Z4
S201-Z6
S201-Z10
S201-Z13
S201-Z16
S201-Z20
S201-Z25
S201-Z32
S201-Z40
S201-Z50
S201-Z63
S202-Z0.5
S202-Z1
S202-Z1.6
S202-Z2
S202-Z3
S202-Z4
S202-Z6
S202-Z10
S202-Z13
S202-Z16
S202-Z20
S202-Z25
S202-Z32
S202-Z40
S202-Z50
S202-Z63

No. of
poles

Rated
current

3

0.5
1
1.6
2
3
4
6
10
13
16
20
25
32
40
50
63

4

0.5
1
1.6
2
3
4
6
10
13
16
20
25
32
40
50
63

Catalog number

S203-Z0.5
S203-Z1
S203-Z1.6
S203-Z2
S203-Z3
S203-Z4
S203-Z6
S203-Z10
S203-Z13
S203-Z16
S203-Z20
S203-Z25
S203-Z32
S203-Z40
S203-Z50
S203-Z63
S204-Z0.5
S204-Z1
S204-Z1.6
S204-Z2
S204-Z3
S204-Z4
S204-Z6
S204-Z10
S204-Z13
S204-Z16
S204-Z20
S204-Z25
S204-Z32
S204-Z40
S204-Z50
S204-Z63

Tripping characteristic Z
UL 1077
480Y/277VAC
6 kA
S203-Z0.5

15

Resistive loads
• Z Curve
• Designed to provide maximum protection
with a very low shirt circuit trip setting
• Example: semiconductors

Accessories & technical data

Accessories – See page 15.31 - 15.34
Technical data – See page 15.35 - 15.36
S204-Z0.5

Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com

cir Min
cu ia
it b tur
S2 rea e
00 ke
r

S200P-B, 480Y/277 VAC
Supplemental protectors
UL 1077, CSA 22.2, No. 235

B

No. of
poles

1

S210P-B6

2

S210P-B6

Rated
current

6
10
13
16
20
25
32
40
50
63
6
10
13
16
20
25
32
40
50
63

Catalog number

S201P-B6
S201P-B10
S201P-B13
S201P-B16
S201P-B20
S201P-B25
S201P-B32
S201P-B40
S201P-B50
S201P-B63
S202P-B6
S202P-B10
S202P-B13
S202P-B16
S202P-B20
S202P-B25
S202P-B32
S202P-B40
S202P-B50
S202P-B63

s

No. of
poles

3

4

Rated
current

6
10
13
16
20
25
32
40
50
63
6
10
13
16
20
25
32
40
50
63

Catalog number

S203P-B6
S203P-B10
S203P-B13
S203P-B16
S203P-B20
S203P-B25
S203P-B32
S203P-B40
S203P-B50
S203P-B63
S204P-B6
S204P-B10
S204P-B13
S204P-B16
S204P-B20
S204P-B25
S204P-B32
S204P-B40
S204P-B50
S204P-B63

Tripping characteristic B
UL 1077
480Y/277 VAC
10 kA

Resistive loads
• B Curve
• Designed for use in cable protection
applications
• Example: Control circuits, lighting
S210P-B6

Accessories & technical data

Accessories – See page 15.31 - 15.34
Technical data – See page 15.35 - 15.36

15

S210P-B6

Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com

re s
tu ker
a
i
in ea
M it br 0
cu S20
cir

C

S200P-C, 480Y/277 VAC
Supplemental protectors
UL 1077, CSA 22.2, No. 235
No. of
poles

S210P-B6

1

S210P-B6

2

S210P-B6

Rated
current

0.5
1
1.6
2
3
4
6
8
10
13
16
20
25
32
40
50
63
0.5
1
1.6
2
3
4
6
8
10
13
16
20
25
32
40
50
63

Catalog number

S201P-C0.5
S201P-C1
S201P-C1.6
S201P-C2
S201P-C3
S201P-C4
S201P-C6
S201P-C8
S201P-C10
S201P-C13
S201P-C16
S201P-C10
S201P-C25
S201P-C32
S201P-C40
S201P-C50
S201P-C63
S202P-C0.5
S202P-C1
S202P-C1.6
S202P-C2
S202P-C3
S202P-C4
S202P-C6
S202P-C8
S202P-C10
S202P-C13
S202P-C16
S202P-C10
S202P-C25
S202P-C32
S202P-C40
S202P-C50
S202P-C63

No. of
poles

3

Rated
current

0.5
1
1.6
2
3
4
6
8
10
13
16
20
25
32
40
50
63

Catalog number

S203P-C0.5
S203P-C1
S203P-C1.6
S203P-C2
S203P-C3
S203P-C4
S203P-C6
S203P-C8
S203P-C10
S203P-C13
S203P-C16
S203P-C10
S203P-C25
S203P-C32
S203P-C40
S203P-C50
S203P-C63

Tripping characteristic C

15

UL 1077
480Y/277 VAC
10 kA

Resistive loads
• C Curve
• Designed for use with medium magnetic
start up currents
• Example: Lighting, control panels

Accessories & technical data

Accessories – See page 15.31 - 15.34
Technical data – See page 15.35 - 15.36

Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com

cir Min
cu ia
it b tur
S2 rea e
00 ke
r

S200P-D, 480Y/277 VAC
Supplemental protectors
UL 1077, CSA 22.2, No. 235

D

No. of
poles

S201P-D0.5

1

S202P-D0.5

2

S203P-D0.5

Rated
current

0.5
1
1.6
2
3
4
6
8
10
13
16
20
25
32
40
50
63
0.5
1
1.6
2
3
4
6
8
10
13
16
20
25
32
40
50
63

Catalog number

S201P-D0.5
S201P-D1
S201P-D1.6
S201P-D2
S201P-D3
S201P-D4
S201P-D6
S201P-D8
S201P-D10
S201P-D13
S201P-D16
S201P-D10
S201P-D25
S201P-D32
S201P-D40
S201P-D50
S201P-D63
S202P-D0.5
S202P-D1
S202P-D1.6
S202P-D2
S202P-D3
S202P-D4
S202P-D6
S202P-D8
S202P-D10
S202P-D13
S202P-D16
S202P-D10
S202P-D25
S202P-D32
S202P-D40
S202P-D50
S202P-D63

s

No. of
poles

Rated
current

3

0.5
1
1.6
2
3
4
6
8
10
13
16
20
25
32
40
50
63

Catalog number

S203P-D0.5
S203P-D1
S203P-D1.6
S203P-D2
S203P-D3
S203P-D4
S203P-D6
S203P-D8
S203P-D10
S203P-D13
S203P-D16
S203P-D10
S203P-D25
S203P-D32
S203P-D40
S203P-D50
S203P-D63

Tripping characteristic D
UL 1077
480Y/277 VAC
10 kA

Inductive loads
• D Curve
• Designed for allowing higher in-rush
currents during system start up
• Example: motors, transformers

Accessories & technical data

Accessories – See page 15.31 - 15.34
Technical data – See page 15.35 - 15.36

Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com

15

re s
tu ker
a
i
in ea
M it br 0
cu S20
cir

K

S200P-K, 480Y/277 VAC
Supplemental protectors
UL 1077, CSA 22.2, No. 235
No. of
poles

1

S201P-K

2

S202P-K

Rated
current

0.2
0.3
0.5
0.75
1
1.6
2
3
4
6
8
10
13
16
20
25
32
40
50
63
0.2
0.3
0.5
0.75
1
1.6
2
3
4
6
8
10
13
16
20
25
32
40
50
63

Catalog number

S201P-K0.2
S201P-K0.3
S201P-K0.5
S201P-K0.75
S201P-K1
S201P-K1.6
S201P-K2
S201P-K3
S201P-K4
S201P-K6
S201P-K8
S201P-K10
S201P-K13
S201P-K16
S201P-K20
S201P-K25
S201P-K32
S201P-K40
S201P-K50
S201P-K63
S202P-K0.2
S202P-K0.3
S202P-K0.5
S202P-K0.75
S202P-K1
S202P-K1,6
S202P-K2
S202P-K3
S202P-K4
S202P-K6
S202P-K8
S202P-K10
S202P-K13
S202P-K16
S202P-K20
S202P-K25
S202P-K32
S202P-K40
S202P-K50
S202P-K63

No. of
poles

3

Rated
current

0.2
0.3
0.5
0.75
1
1,6
2
3
4
6
8
10
13
16
20
25
32
40
50
63

Catalog number

S203P-K0.2
S203P-K0.3
S203P-K0.5
S203P-K0.75
S203P-K1
S203P-K1,6
S203P-K2
S203P-K3
S203P-K4
S203P-K6
S203P-K8
S203P-K10
S203P-K13
S203P-K16
S203P-K20
S203P-K25
S203P-K32
S203P-K40
S203P-K50
S203P-K63

Tripping characteristic K
UL 1077
480Y/277 VAC
10 kA

15

Inductive loads
• K Curve
• Designed for allowing higher in-rush
currents during system start up
• Example: motors, transformers

Accessories & technical data
S203P-K

Accessories – See page 15.31 - 15.34
Technical data – See page 15.35 - 15.36

Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com

cir Min
cu ia
it b tur
S2 rea e
00 ke
r

S200P-Z, 480Y/277 VAC
Supplemental protectors
UL 1077, CSA 22.2, No. 235

Z

No. of
poles

1

S201P-Z

2

Rated
current

0.5
1
1.6
2
3
4
6
8
10
16
20
25
32
40
50
63
0.5
1
1.6
2
3
4
6
8
10
16
20
25
32
40
50
63

Catalog number

S201P-Z0.5
S201P-Z1
S201P-Z1.6
S201P-Z2
S201P-Z3
S201P-Z4
S201P-Z6
S201P-Z8
S201P-Z10
S201P-Z16
S201P-Z20
S201P-Z25
S201P-Z32
S201P-Z40
S201P-Z50
S201P-Z63
S202P-Z0.5
S202P-Z1
S202P-Z1.6
S202P-Z2
S202P-Z3
S202P-Z4
S202P-Z6
S202P-Z8
S202P-Z10
S202P-Z16
S202P-Z20
S202P-Z25
S202P-Z32
S202P-Z40
S202P-Z50
S202P-Z63

s

No. of
poles

Rated
current

3

0.5
1
1.6
2
3
4
6
8
10
16
20
25
32
40
50
63

Catalog number

S203P-Z0.5
S203P-Z1
S203P-Z1.6
S203P-Z2
S203P-Z3
S203P-Z4
S203P-Z6
S203P-Z8
S203P-Z10
S203P-Z16
S203P-Z20
S203P-Z25
S203P-Z32
S203P-Z40
S203P-Z50
S203P-Z63

Tripping characteristic Z

S202P-Z

UL 1077
480Y/277 VAC
10 kA

Resistive loads
• Z Curve
• Designed to provide maximum
protection with a very low short
circuit trip setting
• Example: semiconductors

Accessories & technical data

Accessories – See page 15.31 - 15.34
Technical data – See page 15.35 - 15.36

S203P-Z

Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com

15

re s
tu ker
a
i
in ea
M it br 0
cu S20
cir

K

S200PR-K, 240 VAC, Ring tongue
Supplemental protectors
UL1077, CSA 22.2 No. 235
No. of
poles

1

S201PR-K0.2

S202PR-K0.2

2

15

S203PR-K0.2

Rated
current

Catalog number

0.2
0.3
0.5
0.75
1
1.6
2
3
4
5
6
8
10
13
15
16
20
25
30
32
35
40
50
60
63
0.2
0.3
0.5
0.75
1
1.6
2
3
4
5
6
8
10
13
15
16
20
25
30
32
35
40
50
60
63

S201PR-K0.2
S201PR-K0.3
S201PR-K0.5
S201PR-K0.75
S201PR-K1
S201PR-K1.6
S201PR-K2
S201PR-K3
S201PR-K4
S201PR-K5
S201PR-K6
S201PR-K8
S201PR-K10
S201PR-K13
S201PR-K15
S201PR-K16
S201PR-K20
S201PR-K25
S201PR-K30
S201PR-K32
S201PR-K35
S201PR-K40
S201PR-K50
S201PR-K60
S201PR-K63
S202PR-K0.2
S202PR-K0.3
S202PR-K0.5
S202PR-K0.75
S202PR-K1
S202PR-K1.6
S202PR-K2
S202PR-K3
S202PR-K4
S202PR-K5
S202PR-K6
S202PR-K8
S202PR-K10
S202PR-K13
S202PR-K15
S202PR-K16
S202PR-K20
S202PR-K25
S202PR-K30
S202PR-K32
S202PR-K35
S202PR-K40
S202PR-K50
S202PR-K60
S202PR-K63

No. of
poles

3

4

Rated
current

0.2
0.3
0.5
0.75
1
1.6
2
3
4
5
6
8
10
13
15
16
20
25
30
32
35
40
50
60
63
0.2
0.3
0.5
0.75
1
1.6
2
3
4
5
6
8
10
13
15
16
20
25
30
32
35
40
50
60
63

Catalog number

S203PR-K0.2
S203PR-K0.3
S203PR-K0.5
S203PR-K0.75
S203PR-K1
S203PR-K1.6
S203PR-K2
S203PR-K3
S203PR-K4
S203PR-K5
S203PR-K6
S203PR-K8
S203PR-K10
S203PR-K13
S203PR-K15
S203PR-K16
S203PR-K20
S203PR-K25
S203PR-K30
S203PR-K32
S203PR-K35
S203PR-K40
S203PR-K50
S203PR-K60
S203PR-K63
S204PR-K0.2
S204PR-K0.3
S204PR-K0.5
S204PR-K0.75
S204PR-K1
S204PR-K1.6
S204PR-K2
S204PR-K3
S204PR-K4
S204PR-K5
S204PR-K6
S204PR-K8
S204PR-K10
S204PR-K13
S204PR-K15
S204PR-K16
S204PR-K20
S204PR-K25
S204PR-K30
S204PR-K32
S204PR-K35
S204PR-K40
S204PR-K50
S204PR-K60
S204PR-K63

Tripping characteristic K
UL 1077
480Y/277 VAC
10 kA

Inductive loads
• K Curve
• Designed for allowing higher in-rush currents
during system start up
• Example: motors, transformers

Accessories & technical data

Accessories – See page 15.31 - 15.34
Technical data – See page 15.35 - 15.36
S203PR-K0.2

Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com

cir Min
cu ia
it b tur
S2 rea e
00 ke
r

S280UC-K, 500 VDC
Supplemental protectors
UL 1077, CSA 22.2, No. 235

K

No. of
poles

1

S281UC-K

2

S282UC-K

Rated
current

Catalog number

 0,2
 0,3
 0,5
 0,75
 1
 1,6
 2
 3
 4
 6
 8
10
16
20
25
32
40
50
63
 0,2
 0,3
 0,5
 0,75
 1
 1,6
 2
 3
 4
 6
 8
10
16
20
25
32
40
50
63

S281UC-K0.2
S281UC-K0.3
S281UC-K0.5
S281UC-K0.75
S281UC-K1
S281UC-K1.6
S281UC-K2
S281UC-K3
S281UC-K4
S281UC-K6
S281UC-K8
S281UC-K10
S281UC-K16
S281UC-K20
S281UC-K25
S281UC-K32
S281UC-K40
S281UC-K50
S281UC-K63
S282UC-K0.2
S282UC-K0.3
S282UC-K0.5
S282UC-K0.75
S282UC-K1
S282UC-K1.6
S282UC-K2
S282UC-K3
S282UC-K4
S282UC-K6
S282UC-K8
S282UC-K10
S282UC-K16
S282UC-K20
S282UC-K25
S282UC-K32
S282UC-K40
S282UC-K50
S282UC-K63

s

No. of
poles

Rated
current

3

 0.2
 0.3
 0.5
 0.75
 1
 1.6
 2
 3
 4
 6
 8
10
16
20
25
32
40
50
63

Catalog number

S283UC-K0.2
S283UC-K0.3
S283UC-K0.5
S283UC-K0.75
S283UC-K1
S283UC-K1.6
S283UC-K2
S283UC-K3
S283UC-K4
S283UC-K6
S283UC-K8
S283UC-K10
S283UC-K16
S283UC-K20
S283UC-K25
S283UC-K32
S283UC-K40
S283UC-K50
S283UC-K63

Tripping characteristic K

UL 1077
250/500 VDC
10 kA
Inductive loads
• K Curve
• Designed for allowing higher in-rush
currents during system start up
• Example: motors, transformer

Accessories & technical data

Accessories – See page 15.31 - 15.34
Technical data – See page 15.35 - 15.36

S283UC-K

Direct current applications

500 VDC
Two Pole
S201DC

S282UC

3+

The S280UC differs from standard miniature circuit breakers in that the UC versions
include a permanent magnet which aids in the
extinguishing of the arc during medium and
high level faults. It is necessary to observe the
correct polarity and current direction when
connecting the UC breakers. Two examples of
correct connection are shown.
Termination points are marked on all UC type
MCBs, points one (1) and four (4) are negative
and points two (2) and three (3) are positive.

4LOAD

Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com

15

re s
tu ker
a
i
in ea
M it br 0
cu S20
cir

S280UC-Z, 500 VDC
Supplemental protectors
UL 1077, CSA 22.2, No. 235

Z

No. of
poles

1

S281UC-Z

2

Rated
current

 0.5
 1
 1.6
 2
 3
 4
 6
 8
10
16
20
25
32
40
50
63
 0.5
 1
 1.6
 2
 3
 4
 6
 8
10
16
20
25
32
40
50
63

Catalog number

S281UC-Z0.5
S281UC-Z1
S281UC-Z1.6
S281UC-Z2
S281UC-Z3
S281UC-Z4
S281UC-Z6
S281UC-Z8
S281UC-Z10
S281UC-Z16
S281UC-Z20
S281UC-Z25
S281UC-Z32
S281UC-Z40
S281UC-Z50
S281UC-Z63
S282UC-Z0.5
S282UC-Z1
S282UC-Z1.6
S282UC-Z2
S282UC-Z3
S282UC-Z4
S282UC-Z6
S282UC-Z8
S282UC-Z10
S282UC-Z16
S282UC-Z20
S282UC-Z25
S282UC-Z32
S282UC-Z40
S282UC-Z50
S282UC-Z63

No. of
poles

Rated
current

3

 0.5
 1
 1.6
 2
 3
 4
 6
 8
10
16
20
25
32
40
50
63

Catalog number

S283UC-Z0.5
S283UC-Z1
S283UC-Z1.6
S283UC-Z2
S283UC-Z3
S283UC-Z4
S283UC-Z6
S283UC-Z8
S283UC-Z10
S283UC-Z16
S283UC-Z20
S283UC-Z25
S283UC-Z32
S283UC-Z40
S283UC-Z50
S283UC-Z63

Tripping characteristic Z
UL 1077
250/500 VDC
10 kA

S282UC-Z

Resistive loads
• Z Curve
• Designed to provide maximum
protection with a very low short
circuit trip setting
• Example: semiconductors

15

Accessories & technical data

Accessories – See page 15.31 - 15.34
Technical data – See page 15.35 - 15.36

Direct current applications

The S280UC differs from standard miniature circuit breakers in that the UC versions
include a permanent magnet which aids in the
extinguishing of the arc during medium and
high level faults. It is necessary to observe the
correct polarity and current direction when
connecting the UC breakers. Two examples of
correct connection are shown.

S283UC-Z

500 VDC
Two Pole
S201DC

Termination points are marked on all UC type
MCBs, points one (1) and four (4) are negative
and points two (2) and three (3) are positive.

S282UC

3+
4LOAD

Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com

cir Min
cu ia
it b tur
S2 rea e
00 ke
r

Accessories
S200, S200P & S200PR
UL 1077, CSA 22.2, No. 235

s

Auxiliary contacts

The auxiliary contacts will signal whether the breaker is in the ON or OFF position.
Description

For field mounting: right side

Catalog number

S2C-H6R

Bell alarm - signal contact

The bell alarm includes a set of contacts that will only signal when the breaker has tripped.
Typically the contacts would be connected to an alarm or bell to signal the operator that an overcurrent trip
has occurred. The bell alarm also includes a test button for testing the alarm contacts without opening the
breaker.
Description
S2C-H6R

For field mounting: right side

Catalog number

S2C-S/H6R 1

Shunt trip

For remote tripping of breaker, a shunt trip device can be added to the MCB. The solenoid device opens the
breaker after control voltage is applied.
Description

For field mounting: right side
A1-12-60 VAC (12 – 60 VDC)
A2-110-415 VAC (110 – 250 VDC)

Catalog number

S2C-A1
S2C-A2

Undervoltage release

When control voltage drops below approximately 50 % of rated voltage, the UVR opens the breaker.
The breaker can not be operated unless proper control voltage is first applied to the UVR coil.
Description

S2C-A

For field mounting: right side
	
12 VDC
	
24 VAC/VDC
	 48 VAC/VDC
	 110 VAC/VDC
	 220 VAC/VDC
	 380 VAC

Catalog number

S2C-UA 12
S2C-UA 24
S2C-UA 48
S2C-UA 110
S2C-UA 230
S2C-UA 400

Possible mounting arrangements of MCB accessories

15
Legend

S2C-UA

Auxiliary contact
+ST+H+H+H)
+ST+S/H+S/H (H)+S/H (H)

SA 1

H

Bell alarm/Auxiliary contact

S/H

Bell alarm/Auxiliary contact
used as auxiliary contact

S/H (H)

Shunt trip

ST

Undervoltage release

UR

Locking devices
Description

Catalog number

Locking devices, 3 mm

SA1

Padlock with 2 keys

SA2

SA 2

1 Combination bell alarm/auxiliary contact.

Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com

re s
tu ker
a
i
in ea
M it br 0
cu S20
cir

Accessories
S200PR
UL 1077, CSA 22.2, No. 235

S200PR Accessory overview
H

Auxiliary contact S2C-H6R

H-R

Auxiliary contact S2C-H6-...R

S/H

Signal/Auxiliary contact S2C-S/H6R

S/H (H) Signal/Auxiliary contact S2C-S/H6R
used as auxiliary contact
ST

Shunt trip S2C-A...

UR

Undervoltage release S2C-UA

S200PR Instructions for use

15

Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com

cir Min
cu ia
it b tur
S2 rea e
00 ke
r

Accessories
S280UC
UL 1077, CSA 22.2, No. 235

s

Shunt trips
Function: remote opening of the device when a voltage is applied
Suitable for MCBs S 280 and S 280 UC series.
Description

S2-A1 I
S2-A2 I
C1

1

1

C1

C2

2

2

C2

110-415 VAC and 110-250 VDC shunt trip

S2-A2

Signal contacts
Function: indication of the position of the device’s contacts only after the automatic release of the MCBs
and RCBOs due to an overload or a short-circuit
Suitable for MCBs S 280 and S 280 UC series

S 290 A1
S 290 A2

2

S2-A1

Auxiliary contacts
Function: indication of the position of the device’s contacts
Suitable for MCBs S 280 and S 280 UC series

S2-A1

1

Catalog number

12-60 VAC/VDC shunt trip

Description

C1

C2

Catalog number

Auxiliary contact 1 NO + 1 NC (1/2 module)

S2-H11

Auxiliary contact 2 NO (1/2 module)

S2-H20

Auxiliary contact 2 NC (1/2 module)

S2-H02

Auxiliary contact 1 NO + 1 NC (1/2 module) with Faston connections

S2-H11X

Auxiliary contact 2 NO (1/2 module) with Faston connections

S2-H20X

S9-T24, S9-T130, S9-T415

S5 AL Auxiliary contact 2 NC (1/2 module) with Faston connections

S2-H02X

C1

C1

C2

1

2

1

C2

Auxiliary contact 2 NO + 1 NC (1/2 module)

S2-H21

Auxiliary contact 1 NO + 2 NC (1/2 module)

S2-H12

Auxiliary
contact 3 NO (1/2 module)
2

S2-H30

InstallationAuxiliary
only on leftcontact

3 NC (1/2 module)

S2-H03

Signal contact (1/2 module)

S2-S

Signal contact + Auxiliary contact (1/2 module)

S2-S/H

Undervoltage release
Function: protection of the load in the event of a voltage drop (between 70% and 35% of its rated value);
positive safety (device’s tripping when the voltage is disconnected) emergency stop by means of a button.
Suitable for MCBs S 280 and S 280 UC series.
Description

S2-UA12

S2-UA12

Undervoltage release 24V AC/DC (1 module)

S2-UA24

Undervoltage release 48V AC/DC (1 module)

S2-UA48

Undervoltage release 110V AC/DC (1 module)

S2-UA110

Undervoltage release 220V AC/DC (1 module)

S2-UA220

Undervoltage release 380V AC (1 module)	

S2-UA380

S2-H11	
S2-h11 X	

S2-H20	 S2-H02	S2-H21	
S2-H20 X	
S2-H02 X

S2-H12	

S2-H30	 S2-H03

13 21 1

13 23 1

11 21 1

11 23 33 1

11 21 33 1

13 23 33 1

11 21 31 1

14 22 2

14 24 2

12 22 2

12 24 34 2

12 22 34 2

14 24 34 2

12 22 32 2

S2-S
95

15

Catalog number

Undervoltage release 12V DC (1 module)

1 95

Automatic
ManualManual
Automatic
openingopening
openingopening
1 95

1 95

1 95

1 95

1

96 98 2 96 98 296 98 2 96 98 296 98 2 96 98 2

S2-S/H
95

11 95 1

11

Automatic
Automatic Manual Manual
openingopening openingopening

95
1

11 95 1

11

95
1

11 95 1

11

1

96 98 12 96
14 982 12 1496298 12 96
14 98
2 12 1496298 12 96
14 98
2 12 14 2

Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com

re s
tu ker
a
i
in ea
M it br 0
cu S20
cir

Accessories
S280UC
UL 1077, CSA 22.2, No. 235
Hand operated neutral
The hand operated neutral has to be mounted to the left side of the MCB and be snapped on the DIN rail.
It is used for measuring duties where the neutral conductor must be in the open position. Due to the special
design of the handle - when switching ON the MCB – the neutral will make before the MCB is closed.
The S2C - Nt is not to switch with a tool (screw driver).
Description

Hand operated neutral	

Catalog number

S2-NT

15

Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com

Schemes for combination and technical features
Auxiliary elements for MCBs S 280 series

cir Min
cu ia
it b tur
S2 rea e
00 ke
r

s

Combination between auxiliary elements and S 280

H

S 280

S/H

ST

UR

S

UR
H

ST

S

H
S
UR
ST

Auxiliary contact
Signal contact
Undervoltare release
Shunt trip

S

S/H

Technical characteristics of auxiliary and signal contacts
Type		
		

S2-H11 I	
S2-H11 X	

S2-H20 I	
S2-H20 X	

Description		
1NO+1NC	2NO	

S2-H02 I	
S2-H02 X

S2-H21	

S2-H12	

S2-H30	

2NC	2NO+1NC	
1NO+2NC	3NO	

S2-H03
3NC

Alternating	
Ue [V]	•••••••••••••••••••••••••••••••	
	
240	 415
current	
Ie [A]	•••••••••••••••••••••••••••••••	
	 6	2
Direct	
Ue [V]	••••••••••••••••••••••••	
24	 60	 110	250
current	
Ie [A]	••••••••••••••••••••••••	
4	 2	1.5	 1
Min.operating
voltage	[V]	
	
		
12 a.c.-12 d.c.
Min. operating
current	 [mA]				
12
up to 2x1.5
Terminals 	
[mm2]				
Dielectric strength 	
[kV]				
3
Resistance to short-circuit
at 240 V a.c.	
[A]			
1000 (protected with S 2 breaker characteristic K - 6 A)
Impulse voltage withstand
capacity 	[kV]				4
Tightening torque 	
[Nm]				
0.7
Dimensions (WxDxH) 	 [mm]				
8.75x68x90
NB: 	the auxiliary contacts S2-H11 X, S2-H20 X, S2-H02 X differ from the contacts S2-H11, S2-H20, S2-H02 in that they do not have a terminal to tighten the cable
which is replaced by a bayonet for the Faston connection.

Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com

15

re s
tu ker
a
i
in ea
M it br 0
cu S20
cir

Technical features
Auxiliary elements for MCBs S 280 series

Technical characteristics of shunt trips
Type		
S2-A1	S2-A2
Rated voltage 	
[V]
	
a.c.	
12 - 60	
110 - 415	
d.c.	
12 - 60	
110 - 250	
	
Max. release duration 	
[ms]	
<10	
<10	
Min. release 	
[V]
voltage 	
a.c. 	
7	
55
	
d.c.	10	
80
Consumption on release 	 [VA]
	
12 V a.c.	
35		
	
12 V d.c.	
30		
	
24 V a.c.	
140		
	
24 V d.c.	
100		
	
48 V a.c.	
600		
	
48 V d.c.	
330		
	
110 V a.c.		
40	
	
110 V d.c.		
40	
	
220 V a.c.		
180	
	
220 V d.c.		
170	
Coil resistance
	
[Ω]	
3.7	
225
Terminals	[mm2]	25	
25	
Tightening torque	
[Nm]	
2	
2	
Dimens.(WxDxH) 	

[mm]	

17.5x68x90	

17.5x68x90	

Technical characteristics of undervoltage releases
Type		
S2-UA 12	
S2-UA 24	
S2-UA 48		
S2-UA 110	
S2-UA 220	
S2-UA 380
Standards				
VDE0660 part I - IEC EN 60947.1
Rated
	[V] a.c.	
-	
24	
48		
110	
220-240	
380
	 [V] d.c.	
12	
24	
-		
110	
220-240	
380
voltage
Frequency 	 [Hz]				
50...60
Release trip 	[V]	
			
0.35 Un≤V≤0.7 Un	
Terminals	[mm2]				
2 x 1.5
Consumption 	[mA]				
10
15 Resistance to corrosion 	 [°C/RH]			const. climatic cond.: 23/83-40/93-55/20; var. climatic cond.: 25/95-40/93
Protection degree					
IP20
[Nm]				
0.4
Tightening torque 	
Dimensions (WxDxH) 	
[mm]				
17.5x68x90

	

S2-S						

	
1 change over						
			
240		415
			
6		2
		
250	
110		 60	
24
		
0.5	
1		1	
4

S2-SH
2 change over

				12 a.c.-12 d.c.
				12
				 up to 2x1.5
				3
			1000 (protected with S 2 breaker characteristic K - 6 A)
				4
				0.7
				8.75x68x90

Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com

Accessories
S200 & S200P
UL 1077, CSA 22.2, No. 235 (suitable for cutting)

cir Min
cu ia
it b tur
S2 rea e
00 ke
r

s

1 Phase
For
use on:

Amp
rating

Number
of poles

Phases

Busbar length
(mm)

End cap
catalog number

S200
S200 P

63
80

60
60

1
1

986
986

PS-END0
PS-END0

For
use on:

Amp
rating

Number
of poles

Phases

Busbar length
(mm)

End cap
catalog number

S200
S200 P

63
80

58
58

2
2

1035
1035

PS-ENDSP
PS-ENDSP

For
use on:

Amp
rating

Number
of poles

Phases

Busbar length
(mm)

End cap
catalog number

S200
S200 P

63
80

60
60

3
3

1065
1065

For
use on:

Amp
rating

Number
of poles

Phases

Busbar length
(mm)

S200

80

60

4

1056

Catalog
number

PS1/60SP
PS1/60/16SP

1 Phase

2 Phase

2 Phase

3 Phase

4 Phase

Catalog
number

PS2/58SP
PS2/58/16SP

3 Phase
PSB-ENDSP
PSB-ENDSP

Catalog
number

PS3/60SP
PS3/60/16SP

4 Phase
End cap
catalog number

PS-END1

Catalog
number

PS4/60/16SP

NOTE
All busbars may be center fed in order
to increase ampacity up to 130 A.

NOTE
Busbars may be used on line or
load side of MCBs

Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com

15

re s
tu ker
a
i
in ea
M it br 0
cu S20
cir

Accessories
S200 & S200P
UL 1077, CSA 22.2, No. 235
1 Phase with 1 auxiliary
For
use on:

Amp
rating

Number
of poles

Phases

Busbar length
(mm)

End cap
catalog number

S200 &
S200 P

63
80

38
38

1
1

1044
1044

–
–

Catalog
number

PS1/38H
PS1/38/16H

1 Phase + Aux

2 Phase with 1 auxiliary
For
use on:

Amp
rating

Number
of poles

Phases

Busbar length
(mm)

End cap
catalog number

S200 &
S200 P

80

48

2

1065

PS-ENDSP

Catalog
number

PS2/48/16SP

2 Phase + Aux

3 Phase with 1 auxiliary
For
use on:

Amp
rating

Number
of poles

Phases

Busbar length
(mm)

End cap
catalog number

S200 &
S200 P

80

39

3

980

PS-ENDSP

Catalog
number

PS3/39/16SP

3 Phase + Aux

3 Phase + N, for use with 2 pole-MCBs on 3 phase/4W system

3 Phase + N

15

For
use on:

Amp
rating

Number
of poles

Phases

Busbar length
(mm)

S200 &
S200 P

80

58

4

1048

End cap
catalog number

Catalog
number

PS-END1SP PS4/58/16NSP

NOTE

NOTE

All busbars may be center fed in order
to increase ampacity up to 130 A.

Busbars may be used on line or
load side of MCBs

Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com

cir Min
cu ia
it b tur
S2 rea e
00 ke
r

Accessories
S200 & S200P
UL 1077, CSA 22.2, No. 235

s

Busbar tooth covers
Description

Covers five unused poles of busbar

Catalog
number

BSK-SP

BSK-SP

Feeder terminals
Description

PS2/6/16 SP

Catalog
number

Insulated with pin contact, 35mm sq.

AST35/15SP

For side by side mounting; feed on pin of busbar, 50mm sq.

SZ-ESKSP

AST35/15SP

SZ-ESK SP

15

Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com

re s
tu ker
a
i
in ea
M it br 0
cu S20
cir

Technical data
S200, S200P, S200PR & S280UC
UL 1077, CSA 22.2, No. 235

Technical data

S200

Specifications:

S200P

UL 1077, CSA C 22.2, VDE 0660, 60898, 60947-2

UL File-Number:
No. of poles:
Tripping characteristics:
Rated current:

E 76126 UL CL
1, 2, 3 & 4
B, C, D, K & Z
0.5-63 A

Rated voltage:

E 76126 UL CL
1, 2, 3 & 4
B, C, D, K & Z
0.2-63 A

Multi pole, 480Y/277 VAC

Short circuit capacity:
Frequency:
Degree of protection:
Mounting position:
Fixing:
Clamps only for Cu:

S200 6kA; S200P 10 kA
50/60 Hz
IP 20
Vertical, horizontal

Service life, mech. and at rated load:

20,000 operations

Tightening torque:
Ambient temperature:

25 in. lbs (2.8 Nm)
– 25°C … – 13°F / 70°C … 158°F
30 g at least 3 impacts, shock duration
of 11 ms

Shock resistance:

S200PR
UL1077, CSA 22.2 No. 235,
IEC 60947-2
E 76126 UL CL
1, 2, 3 & 4
K
0.2-63 A
1 pole, 277 VAC,
Multi pole, 480Y/277 VAC
10 kA
50/60 Hz
IP 20, IP40 in enclosure w/cover
Any
35mm DIN rail
18-4 AWG
6000 ops (AC),
1 cycle (1s -ON, 9s -OFF)

S280UC
UL1077, CSA 22.2, No. 235
–
1, 2, 3
K, Z
0.2-63 A
1 pole, 250 VDC, 230 VAC,
Multipole, 500 VDC, 480 VAC
4.5 kA (10 kA, 60 VD 1P, 125 VDC, 2P
50/60 Hz
IP 20
Any

-25°C ... +55°C

6000 ops (AC/DC),
1 cycle (1s -ON, 9s -OFF)
17.5 in. lbs (2.5 Nm)
-25°C ... +55°C

25g, 2 shocks, 13ms

30g, 3 shocks, 11ms

Auxiliary contact S2C-H6R and Signal contact S2C-S6R for S200, S200P & S200PR
Rated current:
Rated voltage AC / DC:
Contact:
Connection capacity mm2
Tightening torque:
Shock resistance acc. to DIN IEC 68-2-6:
Mechanical service life:

Shunt trip
Rated voltage

AC
DC

Max. release duration
Min. release voltage

15

Consumption on release

AC
DC
AD
DC

Coil resistance
Terminals
Tightening torque

Undervoltage release
Standards
Rated voltage

AC
DC

Frequency
Release trip
Terminals
Consumption
Resistance to corrosion
Protection degree
Tightening torque

10
24
1 pole, single throw
18 – 14 AWG (0.75…2.5)
11 in. Ibs (1.2 Nm)
5 g, 20 frequency cycles 5...150...5 Hz at 24 VAC/DC, 5 mA auto-reclosing < 10 ms
10,000 operations

S2C-A1

S2C-A2

12 ... 60 V
12 ... 60 V
< 10 ms
7V
10 V
40 ... 200 VA
40 ... 200 VA
3.7 Ω
18…6/0.75 – 16 AWG/mm2
18/2 in.Ibs/Nm

110 ... 415 V
110 ... 250 V
< 10 ms
55 V
80 V
55 ... 210 VA
55 ... 110 VA
225 Ω
18…6/0.75 – 16 AWG/mm2
18/2 in.Ibs/Nm

S2C-UA S2C-UA S2C-UA S2C-UA S2C-UA S2C-UA S2C-UA S2C-UA S2C-UA S2C-UA
12 DC
24 AC
24 DC
48 AC
48 DC
110 AC 110 DC 230 AC 230 DC 400 AC
IEC/EN 60947-1
24 V
48 V
110 V
230 V
400 V
12 V
24 V
48 V
110 V
230 V
50 ... 60 Hz
0.35 UnOVO 0.7 Un V
2 x 16/2 x 1.5 AWG/mm2
0.2 VA
3.6 VA
2 VA
3.6 VA
2.1 VA
3.5 VA
2.2 VA
3.7 VA
2.3 VA
2.4 VA
constant atmosphere: 23/83 – 40/93 – 55/20; variable atmosphere: 25/95 – 40/93 °C/RH
IPXXB / IP2X
3.5/0.4 in.Ibs/Nm

Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com

cir Min
cu ia
it b tur
S2 rea e
00 ke
r

Technical data
S200, S200P & S200PR
UL 1077, CSA 22.2, No. 235

s

Internal resistance and power loss
S200PR

Internal resistance per pole in mz, power loss per pole in W	
Type

Rated
current

Device series
B, C, D1

Device series
K

Device series
Z

A

mz

W

mz

W

mz

W

 0.5
 1
 1.6

5500
1440
630

1.4
1.4
1.6

6340
1550
695

1.6
1.6
1.8

10100
2270
1100

2.5
2.3
2.8

 2
3
4

460
150
110

1.8
1.3
1.8

460
165
120

1.9
1.5
2.0

619
202
149

2.5
1.8
2.4

6
8
10

55
15
13.3

2.0
1.0
1.3

52
38
12.6

1.9
2.5
1.26

104
53.9
17.5

3.7
3.45
1.7

13
16
20

13.3
7.0
6.25

2.3
1.8
2.5

12.6
7.7
6.7

1.26
2.0
2.7

10.9
6.0

2.8
2.4

25
32
40

5.0
3.6
3.0

3.2
3.7
4.8

4.6
3.5
2.8

2.9
3.6
4.5

4.1
2.8
2.5

2.6
2.9
4.1

50
63

1.3
1.2

3.25
4.8

1.25
0.7

2.9
5.2

1.8
1.3

4.4
5.2

S200 &
S200P

Rated current

Internal resistance
per pole 4)

Power loss
per pole 4)

mΩ
25300
13700
4740
2067
1270
610
442
140
109
50
54
22
18.2
14.8
8.1
11.1
8.5
5.5
3.8
4.6
3.9
2.8
1.7
1.7
1.9

W
1.01
1.23
1.19
1.16
1.27
1.56
1.77
1.26
1.75
1.26
1.94
1.41
1.82
2.50
1.83
2.83
3.40
3.43
3.39
4.70
4.76
4.40
4.25
6.18
7.56

A
0.2
0.3
0.5
0.75
1
1.5
2
3
4
5
6
8
10
13
15
16
20
25
30
32
35
40
50
60
63

1 Current intensities 0.5 - 4 apply exclusively to C-type trip characteristics

Temperature derating
Max operating current depending on the ambient temperature of a circuit breaker characteristics type B, C and D
B, C, D,
K, & Z

Amps

Ambient Temperatures T (Cº/Fº)
-40/-40
0.67
1.33
2.13
2.67
4.0

-30/-22
0.65
1.29
2.07
2.58
3.9

-20/-4
0.62
1.25
2.00
2.49
3.7

-10/14
0.60
1.20
1.92
2.40
3.6

5.3
8.0
10.7
13.3
17.3

5.2
7.7
10.3
12.9
16.8

5.0
7.5
10.0
12.5
16.2

4.8
7.2
9.6
12.0
15.6

21.3
26.7
33.3
42.7
53.3

20.7
25.8
32.3
41.3
51.6

20.0
24.9
31.2
39.9
49.9

66.7
84.0
112.6
140.7
175.9

64.5
81.3
107.2
134.0
167.5

62.4
78.6
102.1
127.6
159.5

0/32
0.58
1.15
1.85
2.31
3.5

10/50
0.55
1.11
1.77
2.21
3.3

20/68
0.53
1.05
1.69
2.11
3.2

30/86
0.50
1.00
1.60
2.00
3.0

40/104
0.47
0.94
1.51
1.89
2.8

50/122
0.44
0.88
1.41
1.76
2.6

60/140
0.41
0.82
1.31
1.63
2.4

4.6
6.9
9.2
11.5
15.0

4.4
6.6
8.8
11.1
14.4

4.2
6.3
8.4
10.5
13.7

4.0
6.0
8.0
10.0
13.0

3.8
5.7
7.5
9.4
12.3

3.5
5.3
7.1
8.8
11.5

3.3
4.9
6.5
8.2
10.6

3.0
4.5
6.0
7.5
9.7

19.2
24.0
30.0
38.5
48.1

18.5
23.1
28.9
37.0
46.2

17.7
22.1
27.6
35.4
44.2

16.9
21.1
26.4
33.7
42.2

16.0
20.0
25.0
32.0
40.0

15.1
18.9
23.6
30.2
37.7

14.1
17.6
22.0
28.2
35.3

13.1
16.3
20.4
26.1
32.7

11.9
14.9
18.6
23.9
29.8

60.1
75.7
97.2
121.6
151.9

57.7
72.7
92.6
115.8
114.7

55.3
69.6
88.2
110.3
137.8

52.7
66.4
84.0
105.0
131.3

50.0
63.0
80.0
100.0
125.0

47.1
59.4
76.0
95.0
118.8

44.1
55.6
72.2
90.3
112.8

40.8
51.4
68.6
85.7
107.2

37.3
47.0
65.2
81.5
101.8

Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com

70/158
0.37
0.75
1.19
1.49
2.2

15

re s
tu ker
a
i
in ea
M it br 0
cu S20
cir

Technical data
S200 & S200P
UL 1077, CSA 22.2, No. 235

Tripping characteristic B

Tripping characteristic C

Tripping characteristic K

Tripping characteristic Z

Tripping characteristic D

15

Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com

Approximate dimensions
S200, S200P, S200PR
UL 1077, CSA 22.2, No. 235

cir Min
cu ia
it b tur
S2 rea e
00 ke
r

s

S200, S200P

S200PR

SU200PR Instructions for use

15

Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com

re s
tu ker
a
i
in ea
M it br 0
cu S20
cir

Approximate dimensions
S280UC, S2C-H6R, S2C-A...U
UL 1077, CSA 22.2, No. 235

S280UC

S2C-H6R, S2C-A... S2C

Addition of S2C-A...U

LS

15

Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com

Miniature circuit breaker
Application guide

ci Mi
Ap rcui n iat
pli t b ure
cSa re
t2io0 ak
n0 g e rs
uid
e

Introduction

Breaker definition

The circuit breaker plays an important role in providing over-current
protection and a disconnect means in electrical networks. Recent
advancements in circuit breaker technology has increased breaker
performance and protection.

A breaker is a device designed to isolate a circuit during an overcurrent
event without the use of a fusible element. A breaker is a resettable
protective device that protects against two types of overcurrent
situations; Overload and Short Circuit.

Overload
A slow and small overcurrent situation that causes the ampacity and
temperature of the circuit to gradually increase over time. This type of
event is characterized by a slight increase in the load (ampacity) on the
circuit and is interrupted by the thermal trip unit of the breaker.

ABB current limiting breaker
Tripping lever

Electro-magnetic protection

Thermal Example
10A

Thermal
protectionbimetal

15A
Operating
mechanism

Breaker

Upper
terminal

Light

The light draws more than 10 amps for
an extended period of time creating a
thermal overload.

Operator

Short circuit
A rapid and intense overcurrent situation that causes the ampacity of
the circuit to increase. This type of event is characterized by a dramatic
increase in the load (ampacity) on the circuit and is interrupted by the
magnetic trip unit of the breaker.

Arc
chamber

Magnetic Example

10A

Breaker

Fixed
contact

10A

Space for
identification
marker

Moving
contact

Light

The wire connected between the light and
breaker is cut and shorted to ground
creating a short circuit.

Lower terminal

Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com

DIN rail holder

15

re s
tu ker e
a
i
in ea id
M it br n0 gu
cu t2io0
c ir plicSa
Ap

Circuit breaker construction

Thermal / Magnetic trip units definition

Magnetic trip units (short circuit protection)

ABB Current Limiting Breakers use an electromechanical (Thermal /
Magnetic) trip unit to open the breaker contacts during a overcurrent
event. The thermal trip unit is temperature sensitive and the magnetic trip
unit is current sensitive. Both units act independently and mechanically
with the breaker’s trip mechanism to open the breaker’s contacts.

The Magnetic trip unit protects against a short circuit. The magnetic trip
unit is comprised of an electromagnet and an armature.
Armature and Plunger
Movable Contact

Magnet Trip Unit

Current Flow During Operation
Magnetic Trip Unit

Thermal Trip Unit

All highlighted components are energized during operation

Overload protection
The thermal trip unit protects against a continuous overload. The thermal
unit is comprised of a bimetal element located behind the circuit breaker
trip bar and is part of the breaker’s current carrying path. When there is
an overload, the increased current flow heats the bimetal causing it to
bend. As the bimetal bends it pulls the trip bar which opens the breaker’s
contacts.

15

Components of a magnetic trip unit
When there is a short circuit, a high magnitude of current passes through
the coils creating a magnetic field that attracts the movable armature
towards the fixed armature. The hammer trip is pushed against the
movable contact and the contacts are opened. The opening of the
breakers contacts during a short circuit is complete in .5 milli-seconds.

The time required for the bimetal to bend and trip the breaker varies
inversely with the current. Because of this, the tripping time becomes
quicker as current increases in magnitude.
Overload protection is applicable to any installation, conductor, or
component which can be subjected to low-magnitude but long-time overcurrents. Low-magnitude, long-time over-currents can be dangerous
because they reduce the life of the electrical installation, conductor, and
components and if left unchecked could result in fire.

Trip Bar
Operating Mechanism

Thermal Trip Unit

Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com

Circuit breaker construction

ci Mi
Ap rcui n iat
pli t b ure
cSa re
t2io0 ak
n0 g e rs
uid
e

Arc runners / Arc chutes

Breaker curves

The arc runner and arc chute limit and dissipate the arc energy during the
interruption of an overload or short circuit event.

Thermal Trip Unit (region one)
The first sloping region of the breaker curve is a graphical representation
of the tripping characteristics of the thermal trip unit. This portion of the
curve is sloped due to the nature of the thermal trip unit. The trip unit
bends to trip the breaker’s trip bar in conjunction with a rise in amperage
(temperature) over time. As the current on the circuit increases, the
temperature rises, the faster the thermal element will trip.

During an overload or short circuit event, the contacts of the breaker
separate and an electrical arc is formed between the contacts through air.
The arc is moved into the arch chute by “running” the arc down the interior
of the breaker along the arc runner. When the arc reaches the arc chute
it is broken into small segmented arcs. The segmented arcs split the
overall energy level into segments less than 25V. Each 25V segment does
not have a high enough energy level to maintain an arc and all energy is
naturally dissipated.

Arc Runner

Arc Chute

Example using the curve below: If you had a 10A breaker and the circuit
was producing 30 amps of current, the breaker would trip between 2
seconds and 1 minute. In this example you would find the circuit current
on the bottom of the graph (Multiples of rated current). The first line is 10
amps (10 amp breaker x a multiple of one), the second line is 20 amps
(10 amp breaker x multiple of 2), and the third line is 30 amps (10amp
breaker x multiple of 3). Next you would trace the vertical 30A line up until
it intersects the red portion of the breaker thermal curve. If you follow the
horizontal lines, on both sides of the red curve, to the left you will see that
the breaker can trip as fast as 2 seconds and no slower than 1 minute.
Magnetic Trip Unit (region two)
This region of the breaker curve is the instantaneous trip unit. ABB’s
miniature circuit breaker’s instantaneous trip unit interrupts a short circuit
in 2.3 to 2.5 milliseconds. Because of this the curve has no slope and is
graphically represented as a vertical straight line.
Example using the curve above: If you had a 10 amp breaker the magnetic
trip element would interrupt a short circuit between 10 and 30 amps (10
amp breaker x multiple of 2 and 3) in 2.3 to 2.5 milliseconds.
Breaker Contacts (region three)
This region of the curve is the time required for the contacts of the breaker
to begin to separate. The contacts will open in less than .5 milliseconds
and is graphically represented by the bottom vertical portion of the curve.

15

Thermal Trip Unit
(Region One)

Magnetic Trip Unit
(Region Two)

Moving Contacts
(Region Three)

Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com

re s
tu ker e
a
i
in ea id
M it br n0 gu
cu t2io0
c ir plicSa
Ap

Circuit breaker current limitation

Current limiting definitions

Current limiting breakers and electrical networks

All ABB Miniature Circuit Breakers are UL tested and certified as current
limiting protective devices. Current limiting circuit breakers provide a
higher level of circuit protection than a typical zero point external breakers.

Current Limitation
When a short-circuit condition occurs, the “ideal” current limiting circuit
breaker opens before the current waveform can reach its full potential
magnitude which occurs at ¼ cycle (4.17ms). ABB’s current limiting
breakers can interrupt a fault in about ½ cycle or 2.3ms to 2.5ms.

UL AC 60Hz cycle
UL defines an AC cycle as the potential energy of the wave form traveling
from Zero-to-Positive amplitude, Positive-to-Zero amplitude, Zero-toNegative amplitude, Negative-to-Zero amplitude 60 times in one second.
One cycle is completed every 16.6 milliseconds.

UL breaker current limiting
UL defines breaker current limitation as a breaker that interrupts and
isolates a fault in less than 1/2 of an AC cycle. 1/2 a cycle is completed in
8.3 milliseconds.

NEC240.2 current limiting

A device that, when interrupting current in its current-limiting range,
reduces the current flowing in the faulted circuit to a magnitude
substantially less than that obtainable in the same circuit if the device were
replaced with a solid conductor having comparable impedance.

IEC 60947-2 current limiting circuit breaker
A circuit breaker with sufficiently short trip time to prevent the short-circuit
current from reaching the peak value which would otherwise be reached.

ABB current limiting breakers
ABB current limiting breakers can interrupt and isolate a fault in 1/8 of
an AC cycle. The breaker fault interruption is completed in 2.3 to 2.5
milliseconds.

Zero point extinguishing breakers

15

A typical zero point extinguishing breaker interrupts a fault and does not
isolate the energy. The breaker allows an arc to be present between the
open contacts until the AC wave form crosses zero. When the wave
form crosses zero, the potential energy is zero and the arc (fault) naturally
extinguishes. The arc could be present for up to 8.3 milliseconds.

ABB’s current limiting breakers interrupt a short circuit in less than 1/8
cycle and limit the amount of current that can reach a circuit. Limiting
the available current on the circuit provides additional protection against
network, breaker, or bus damage and prevents the tripping of upstream
breakers (selective coordination).

IsqT
The true destructive nature of a short circuit is measured by the time
it is available combined with the peak value of the short circuit. The
IsqT (Amps Squared over Time) value represents the amount of energy
available on a network during a short circuit and is represented by the
shaded area on the graph below.
During a short circuit both magnetic forces and thermal energy combine
to damage devices on the electrical network. The level of thermal energy
and magnetic forces are directly proportional to the square of the current.
The magnetic forces vary as a square of the peak current available and the
thermal energy varies as a square of the RMS (root mean square) current
available. ABB’s current limiting breakers will limit the let-through energy
to a fraction (1/100th) of the value which is available from the network. By
comparison, a Zero Crossing breaker would let-through approximately 100
times as much destructive energy as the current limiting circuit breaker
[ (100,000A / 10,000A) squared – 100X].
ABB’s current limiting breakers limit the short circuit current to a relatively
small magnitude in a extremely short time, which dramatically limits a short
circuit’s destructive energy.

Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com

ci Mi
Ap rcui n iat
pli t b ure
cSa re
t2io0 ak
n0 g e rs
uid
e

Circuit breaker current limitation

Current limiting and zero crossing breakers

Zero crossing example

During the initial stages of a short circuit a breaker’s contacts open to
interrupt the circuit. After the contacts open an arc forms in the air
between the contacts on both the current limiting and zero crossing
breaker contacts. What distinguishes a current limiting breaker from a
zero crossing breaker is what each breaker does after an arc is formed
between the open contacts.

The test report below details a 20A Zero Point Extinguishing breaker
interrupting a 9kA fault in 9 milliseconds. The total "I Square T" value is
104.0kA.

A current limiting breaker “runs” the arc down the breaker arc runner into
an arc chute that extinguishes the arc.
A zero crossing breaker does not attempt to extinguish the arc. The
breaker is designed to withstand the energy of the arc long enough for
the waveform to cross zero. When the wave form crosses zero the
potential energy is zero and the arc naturally extinguishes itself.
ABB’s current limiting breakers interrupt the arc energy in 2.3ms to 2.5ms
(1/8 cycle) and a zero crossing breaker allows the arc to be present for up
to 8.3ms (1/2 cycle). A zero crossing breaker will let through 100 times
as much energy as an ABB current limiting breaker.

500
V

10
kA

400

8

300

6

200

4

100

2

U-BCP L2
100 /div

I-L2
2 k/div

Current limiting example
The lab test report below details a 20A S200 series current limiting
breaker interrupting a 28kA fault in 1.7 milliseconds. The total “I Square
T” value is 32.0kA.

-100

-2

-200

-4

-300

-6

-400

-8

-500

-10

Legend
Voltage

500
V

10
kA

400

8

300

6

200

4

100

2

U-L2
100 /div

Amps
Time A Time B
0
0.9999
499.93 Sample/div

1.9997

2.9996

3.9994

4.9993

15

I-L2
2 k/div

-100

-2

-200

-4

-300

-6

Legend
Voltage

-400

-8

-500

-10

5.9991 6.999
kSample

Amps

Time A Time B
0
0.9999
499.93 Sample/div

1.9997

2.9996

3.9994

4.9993

5.9991 6.999
kSample

Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com

re s
tu ker e
a
i
in ea id
M it br n0 gu
cu t2io0
c ir plicSa
Ap

Selective coordination and series ratings

IEC 60497-1 selective coordination definition

Example of no breaker coordination

Coordination between the operating characteristics of two or more overcurrent protection devices, so that when an over-current within established
limits occurs, the device designated to operate within those limits trips
whereas the other do not trip.

Selective breaker coordination is not achieved when there is an overload
event at the branch breaker level (MCB1) and both the branch breaker
and main breaker interrupt the circuit (open). When there is no breaker
coordination several circuits lose power that should remain operational
during and after the overload event. The chart below gives a graphical
representation of a down stream branch breaker (B curve) and a main
breaker (A curve) without coordination. There is no separation between
the curves. The branch breaker will react to a fault and the main breaker
will open and de-energize all circuits down stream.

Main
breaker

CB1

CB2

CB3

CB4

Short circuit

Example of breaker coordination
When an over-current event occurs at the branch breaker level (CB1), and
the event is within the operating characteristics of the breaker, then the
branch breaker should interrupt the circuit (open) and the main breaker
should remain closed and energized. The chart below gives a graphical
representation of a down stream branch breaker (B curve) and a main
breaker (A curve) with coordination. The separation between the curves
allows the branch breaker to react to the fault and the main breaker
remain closed and energized.

15

Problems in coordination occur when the branch breaker allows the "I
Square T" value of the short circuit to rise to a level that is in the operating
range of the up-stream main breaker. Proper breaker coordination is
easier to achieve with the use of current limiting breakers at the branch
level.

Selective coordination and current limiting breakers
Recent improvements in ABB circuit breaker technology has pushed the
performance of breakers to the same level as fuses. The reaction time
and tripping characteristics of current limiting breakers are now on par with
fuses. This allows ABB to provide a high level of coordination between
branch breakers and the main. A current limiting branch breaker will limit
the “I Square T” value well below the level of the operating range of the upstream main breaker.
ABB’s current limiting branch breakers can coordinate between the main
breaker up to 35kA.

Selective coordination and zero crossing breakers
Zero crossing breakers do not limit the “I Square T” value. They wait for
the wave form to cross zero and allow a high level of let-through energy
to pass through the system. The “I Square T” value of a zero crossing
breaker is high enough that the main breaker will likely trip during a short
circuit. With zero crossing breakers it is extremely difficult to coordinate
between branch and main breakers.
A typical zero crossing breaker’s coordination level is below 10kA. There
are a few manufactures that have achieved coordination between a
branch zero crossing breaker and the main by slowing the performance
(protection) of the main breaker.

Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com

Selective coordination and series ratings

ci Mi
Ap rcui n iat
pli t b ure
cSa re
t2io0 ak
n0 g e rs
uid
e

Series ratings –vs- selective coordination

Series ratings

Selective coordination

Series ratings are different from coordination ratings. Unlike coordination
ratings where the branch opens and the main remains closed, a series
rated combination is one where both the branch and main breakers open
and work together to isolate the fault.

Selective coordination is achieved when there is a short circuit on a branch
circuit breaker, the branch breaker opens and isolates the fault, and the
main breaker remains closed. The rating is usually a value above the
“stand alone” interrupting rating of the branch breaker and the “stand
alone” rating of the main breaker.
Example:
65kA rated main breaker
10kA rated branch breaker
Coordination between the two breakers up to 35kA
There can be a short circuit on the branch breaker up to 35kA where the
branch will open (CB1) and the main breaker will remain closed. Although
the branch has a 10kA “stand alone” rating both the breakers work
together to limit the available short circuit to allow the branch (CB1) to
isolate the fault.

Main
breaker
65 kA

CB1
10 kA

CB2
10 kA

CB3
10 kA

The series rating combination of two breakers is equal to the “stand alone”
interrupting value of the main breaker. This is a result of the main breaker
let-through value being lower than the “stand alone” interrupting value
of the branch breaker. During a short circuit the main breaker will limit
the energy to a level that is below the “stand alone” value of the branch
breaker.
Example:
65kA rated main breaker
10kA rated branch breaker
Series combination rating between the two breakers up to 65kA
There can be a short circuit on the branch breaker up to 65kA where the
branch will open and the main breaker will open. Although the branch
breaker (CB1) has a 10kA “stand alone” rating the main breaker has a letthrough value below 10kA. If there is a fault up to 65kA on the network
the main breaker will limit the energy to a value less than the rating of the
branch breaker (CB1). Both breakers will trip (no coordination) but the
network can safely withstand a fault of 65kA.

CB4
10 kA

35 kA or 65 kA short circuit

15

Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com

re s
tu ker e
a
i
in ea id
M it br n0 gu
cu t2io0
c ir plicSa
Ap

Miniature circuit breaker cutaway

Tripping lever

Electro-magnetic protection
Upper terminal

Thermal
protection-bimetal
Operating
mechanism

Operator

Arc chamber

15

Fixed contact

Space for
identification marker

Moving contact

Lower terminal

DIN rail clip

Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com

High performance circuit breakers

S800 UL 489 Series

S800
High performance circuit
UL 489 Series

cir Min
cu ia
it b tur
S8 rea e
breakers 00 ker

Description

Features

The S800 high performance MCB offers a
compact solution to circuit protection. The
S800 devices are DIN rail mounted. The
S800 is available with application-specific trip
characteristics to provide maximum circuit
protection.

	•	
Energy limiting
	•	
Fast breaking time (2.3 – 2.5 ms)
	•	
Wide range of accessories
	•	
DIN rail mounting
	•	
Finger safe terminals
	•	
Multi-function terminals
	 • Ring tongue compatible
	 •	 UL489 File # E312425
	

The breakers offer thermal-magnetic
trip protection according to Z and K
characteristics.
For the worldwide market, the breakers
carry CSA, IEC, CE and many other agency
approvals.

S800U	
Amperage
Voltage
Poles

10 – 100 A
240 VAC
1, 2, 3, 4 poles

Trip characteristics

Z, K

Interrupting ratings

30kA: UL 489, single pole
50kA: UL 489, multi-pole

Auxiliary contacts

Yes

Bell alarm

Yes

Shunt trip

Yes

Undervoltage release

Yes

Ring tongue

Yes

Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com

s

15

e rs
ur
at ake
i
n
e
i
M it br 0
u
c S80
cir

K

S800U-K, 240 VAC
Branch circuit protection
UL 489
No. of
poles

1

S801U-K

2

Rated
current

10
15
20
25
30
40
50
60
70
80
90
100
10
15
20
25
30
40
50
60
70
80
90
100

S801U-K10
S801U-K15
S801U-K20
S801U-K25
S801U-K30
S801U-K40
S801U-K50
S801U-K60
S801U-K70
S801U-K80
S801U-K90
S801U-K100
S802U-K10
S802U-K15
S802U-K20
S802U-K25
S802U-K30
S802U-K40
S802U-K50
S802U-K60
S802U-K70
S802U-K80
S802U-K90
S802U-K100

Tripping characteristic K
S802U-K

No. of
poles

Catalog number

UL 489
240 VAC
30 kA, single pole
50 kA, multi-pole

Rated
current

10
15
20
25
30
40
50
60
70
80
90
100
10
15
20
25
30
40
50
60
70
80
90
100

3

4

Catalog number

S803U-K10
S803U-K15
S803U-K20
S803U-K25
S803U-K30
S803U-K40
S803U-K50
S803U-K60
S803U-K70
S803U-K80
S803U-K90
S803U-K100
S804U-K10
S804U-K15
S804U-K20
S804U-K25
S804U-K30
S804U-K40
S804U-K50
S804U-K60
S804U-K70
S804U-K80
S804U-K90
S804U-K100

10 000

1000

Resistive loads
• K Curve
• Designed for use in cable protection
applications
• Example: control circuits, lighting

100

Accessories & technical data

10

Accessories – See page 15.52
Technical data – See page 15.76 - 15.82
1

S803U-K
seconds

15

0.1

0.01
1

2

3

10

20

30

multiple of rated current

S804U-K

Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com

cir Min
cu ia
it b tur
S8 rea e
00 ke
r

S800U-Z, 240 VAC
Branch circuit protection
UL 489

Z

No. of
poles

1

S801U-Z

2

Rated
current

10
15
20
25
30
40
50
60
70
80
90
100
10
15
20
25
30
40
50
60
70
80
90
100

s

No. of
poles

Catalog number

S801U-Z10
S801U-Z15
S801U-Z20
S801U-Z25
S801U-Z30
S801U-Z40
S801U-Z50
S801U-Z60
S801U-Z70
S801U-Z80
S801U-Z90
S801U-Z100
S802U-Z10
S802U-Z15
S802U-Z20
S802U-Z25
S802U-Z30
S802U-Z40
S802U-Z50
S802U-Z60
S802U-Z70
S802U-Z80
S802U-Z90
S802U-Z100

3

4

Rated
current

Catalog number

10
15
20
25
30
40
50
60
70
80
90
100
10
15
20
25
30
40
50
60
70
80
90
100

S803U-Z10
S803U-Z15
S803U-Z20
S803U-Z25
S803U-Z30
S803U-Z40
S803U-Z50
S803U-Z60
S803U-Z70
S803U-Z80
S803U-Z90
S803U-Z100
S804U-Z10
S804U-Z15
S804U-Z20
S804U-Z25
S804U-Z30
S804U-Z40
S804U-Z50
S804U-Z60
S804U-Z70
S804U-Z80
S804U-Z90
S804U-Z100

S802U-Z

Tripping characteristic Z

10 000

UL 489
240 VAC
30 kA, single pole
50 kA, multi-pole

S803U-Z

1000

Resistive loads
• Z Curve
• Designed for use in cable protection
applications
• Example: control circuits, lighting

100

Accessories & technical data

15

10

Accessories – See page 15.52
Technical data – See page 15.76 - 15.82

seconds

1

S804U-Z

0.1

0.01
1

2

3

5

10

20

30

multiple of rated current

Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com

e rs
ur
at ake
i
n
e
i
M it br 0
u
c S80
cir

S803W-SCL-SR UL Short circuit current limiter
Self-resetting
UL version short circuit current limiter, self resetting, 3 pole
Item

Catalog number

32A Self resetting current limiter
63A Self resetting current limiter
100A Self resetting current limiter

S803W-SCL32-SR
S803W-SCL63-SR
S803W-SCL100-SR

Technical data
Rated voltage

600 VAC per UL508

Short circuit current rating according to UL508, CSA 22.2

480 VAC 50/60 Hz, 65 kA
600 VAC 50/60 Hz, 65 kA

Approved combinations with motor starter
Downstream devices	

Upstream devices

	S803W-SCL-SR
S803W-SCL-SR

	

Rated current Ie [A]	

Self resetting short-circuit limiter

32		

63		

100

MS/MO325					
0.1– 2.5	

■		■		■

 4	

■		■		■

 6.3	

■		■		■

 9	

■		■		■

12.5	

■		■		■

16	

■		■		■

20			■		■
25			■		■
MS/MO132					
0.1– 2.5	

■		■		

 4	

■		■		

6.3	

■		■		■

10	

■		■		■

16	

■		■		■

20			■		■
25			■		■

15

32			■		■
– Combinations with S500-K and S500-KM on request
■ Applies for all voltages according to the table below

	S803W-SCL-SR
Rated ultimate short-circuit breaking capacity
Short-circuit rating according to UL 508, CSA 22.2
(AC) 50/60 Hz 480 V 	

[kA]	

65

(AC) 50/60 Hz 600 V 	

[kA]	

65

(AC) 50/60 Hz 240/415 V 	

[kA]	

100

(AC) 50/60 Hz 254/440 V 	

[kA]	

100

(AC) 50/60 Hz 277/480 V 	

[kA]	  65

(AC) 50/60 Hz 289/500 V 	

[kA]	  65

(AC) 50/60 Hz 346/600 V 	

[kA]	  65

(AC) 50/60 Hz 400/690 V 	

[kA]	  50

Icu = Ics according to IEC 60947-2

Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com

S803W-SCL-SR UL508 Short circuit current limiter
Approximate dimensions

cir Min
cu ia
it b tur
S8 rea e
00 ke
r

s

Minimum cable length between S803W-SCL-SR and
downstream devices (Connection has to be short-circuit
proofed acc. to IEC 61439-1)

MS/M0325
MS/M0132
S800
S800-SCL-SR	

min. length X	

min. cross section

  32 A	  80 mm	  6 mm2

x

  63 A	  80 mm	

16 mm2

100/125 A	

35 mm2

250 mm	

Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com

15

e rs
ur
at ake
i
n
e
i
M it br 0
u
c S80
cir

S800W-RSU Remote sensing unit
UL489
Remote switching unit
Item

Catalog number

Remote switching unit S800W-RSU

S800W-RSU

S800-RSU cable including plug
Item

Catalog number

3 meter cable 0.5mm2 (AWG20)
inclusing 10 pole Micro Fit 3.0 plug

S800-RSU-CP

Key Features
•	 The remote Switching unit S800W-RSU has a brushless high precision DC motor to ensure fast remote control operation.
S800W-RSU

•	 Low power consumption
•	 Short switching times
•	 The S800W-RSU is mounted on any multipole S800 High Performance MCB
•	 Installation and wiring can be field installable
•	 The connection is done by a 10-pole Micro Fit 3.0 (not included in delivery)
•	 The S800W-RSU can be operated by a standard pushbutton or drive by a PLC

Switching times

S800W-RSU mounted on MCB

•	 OFF -> ON	
	 from signal to contact closing

<<500ms

•	 ON -> OFF	
	 from signal to contact opening

<<250ms

•	 TRIP -> OFF -> ON	
	 from signal to contact closing

<<1500ms

For differing requirements, please contact your local ABB partner

Safety intelligence
•	 Inputs are deactivated when detecting manual use
•	 All outputs become active when spindle is rotated more than 360 degrees
•	 S800W-RSU is locked for 5 minutes after three switching attempts leading to a trip
•	 Manual switch off possible for 3 & 4 pole devices

Technical specifications

15
S800-RSU-CP

Operational voltage

24 VDC

Current consumption Irms

2,5

Standby current IStandby

< 50mA

Switching time OFF-ON

< 500 msec

Switching time ON-OFF

<250 mse

Ambient operation temperature

-25…+70°C

Number of switching operations

10.000

Maximum cable lengths(AWG20/ 0.5mm2)

10m

Degree of protection (mounted)

IP2

Weight

300 gr

Connection

10 pole Micro Fit 3.0

Approximate dimensions

Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com
	

High performance circuit breakers

S800 IEC Series

S800
High performance circuit
IEC Series

Description
The S800 high performance MCB offers
a compact solution to circuit protection.
The S800 devices are IEC tested current
limiting and DIN rail mounted. The S800
is available with application-specific trip
characteristics to provide maximum circuit
protection.
The breakers offer thermal-magnetic
trip protection according to B, C, D & K
characteristics.

Amperage
Voltage
Poles
Trip characteristics
Interrupting ratings
Auxiliary contacts
Bell alarm
Shunt trip
Undervoltage release
Ring tongue

cir Min
cu ia
it b tur
S8 rea e
breakers 00 ker

s

For the worldwide market, the breakers
carry CSA, IEC, CE and many other agency
approvals.
Features
	•	
Current limiting
	•	
Fast breaking time (2.3 – 2.5 ms)
	•	
Wide range of accessories
	•	
DIN rail mounting
	•	
Finger safe terminals
	•	
Multi-function terminals
	•	
Ring tongue compatible

S800S
10 – 125 A
690 VAC
1, 2, 3, 4
B, C, D, K
50 kA : IEC
Yes
Yes
Yes
Yes
Yes

Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com

15

e rs
ur
at ake
i
n
e
i
M it br 0
u
c S80
cir

B

S800S-B, 690 VAC
IEC
No. of
poles

1

S801U-B

2

S802U-B

Rated
current

10
13
16
20
25
32
40
50
63
80
100
125
10
13
16
20
25
32
40
50
63
80
100
125

No. of
poles

Catalog number

S801S-B10
S801S-B13
S801S-B16
S801S-B20
S801S-B25
S801S-B32
S801S-B40
S801S-B50
S801S-B63
S801S-B80
S801S-B100
S801S-B125
S802S-B10
S802S-B13
S802S-B16
S802S-B20
S802S-B25
S802S-B32
S802S-B40
S802S-B50
S802S-B63
S802S-B80
S802S-B100
S802S-B125

Tripping characteristic B

Rated
current

Catalog number

10
13
16
20
25
32
40
50
63
80
100
125
10
13
16
20
25
32
40
50
63
80
100
125

3

4

S803S-B10
S803S-B13
S803S-B16
S803S-B20
S803S-B25
S803S-B32
S803S-B40
S803S-B50
S803S-B63
S803S-B80
S803S-B100
S803S-B125
S804S-B10
S804S-B13
S804S-B16
S804S-B20
S804S-B25
S804S-B32
S804S-B40
S804S-B50
S804S-B63
S804S-B80
S804S-B100
S804S-B125

10 000

IEC
690 VAC
50 kA

1000

Resistive loads
• B Curve
• Designed for use in cable protection
applications
• Example: control circuits, lighting

100

Accessories & technical data
S803U-B

Accessories – See page 15.52
Technical data – See page 15.76 - 15.82

10

15
seconds

1

S804U-B

0.1

0.01
1

2

3

5

10

20

30

multiple of rated current

Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com

cir Min
cu ia
it b tur
S8 rea e
00 ke
r

S800S-C, 690 VAC
IEC

C

No. of
poles

1

S801S-C

2

S802S-C

Rated
current

10
13
16
20
25
32
40
50
63
80
100
125
10
13
16
20
25
32
40
50
63
80
100
125

Catalog number

S801S-C10
S801S-C13
S801S-C16
S801S-C20
S801S-C25
S801S-C32
S801S-C40
S801S-C50
S801S-C63
S801S-C80
S801S-C100
S801S-C125
S802S-C10
S802S-C13
S802S-C16
S802S-C20
S802S-C25
S802S-C32
S802S-C40
S802S-C50
S802S-C63
S802S-C80
S802S-C100
S802S-C125

Tripping characteristic C

s

No. of
poles

Catalog number

10
13
16
20
25
32
40
50
63
80
100
125
10
13
16
20
25
32
40
50
63
80
100
125

3

4

S803S-C10
S803S-C13
S803S-C16
S803S-C20
S803S-C25
S803S-C32
S803S-C40
S803S-C50
S803S-C63
S803S-C80
S803S-C100
S803S-C125
S804S-C10
S804S-C13
S804S-C16
S804S-C20
S804S-C25
S804S-C32
S804S-C40
S804S-C50
S804S-C63
S804S-C80
S804S-C100
S804S-C125

10 000

IEC
690 VAC
50 kA

1000

Resistive loads
• C Curve
• Designed for use with medium magnetic
start up currents
• Example: lighting, control panels

100

Accessories & technical data
S803S-C

Rated
current

10

Accessories – See page 15.52
Technical data – See page 15.76 - 15.82

seconds

1

15

0.1

0.01
1

S804S-C

2

3

5

10

20

30

multiple of rated current

Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com

e rs
ur
at ake
i
n
e
i
M it br 0
u
c S80
cir

D

S800S-D, 690 VAC
IEC
No. of
poles

1

S801S-D

2

S802S-D

Rated
current

10
13
16
20
25
32
40
50
63
80
100
125
10
13
16
20
25
32
40
50
63
80
100
125

No. of
poles

Catalog number

S801S-D10
S801S-D13
S801S-D16
S801S-D20
S801S-D25
S801S-D32
S801S-D40
S801S-D50
S801S-D63
S801S-D80
S801S-D100
S801S-D125
S802S-D10
S802S-D13
S802S-D16
S802S-D20
S802S-D25
S802S-D32
S802S-D40
S802S-D50
S802S-D63
S802S-D80
S802S-D100
S802S-D125

10
13
16
20
25
32
40
50
63
80
100
125
10
13
16
20
25
32
40
50
63
80
100
125

3

4

Catalog number

S803S-D10
S803S-D13
S803S-D16
S803S-D20
S803S-D25
S803S-D32
S803S-D40
S803S-D50
S803S-D63
S803S-D80
S803S-D100
S803S-D125
S804S-D10
S804S-D13
S804S-D16
S804S-D20
S804S-D25
S804S-D32
S804S-D40
S804S-D50
S804S-D63
S804S-D80
S804S-D100
S804S-D125

10 000

Tripping characteristic D
IEC
690 VAC
50 kA

1000

Inductive loads
• D Curve
• Designed for allowing higher in-rush
currents during system start up
• Example: motors, transformers

100

Accessories & technical data
S803S-D

Rated
current

10

Accessories – See page 15.52
Technical data – See page 15.76 - 15.82

1

seconds

15

0.1

0.01
1

S804S-D

2

3

10

20

30

multiple of rated current

Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com

cir Min
cu ia
it b tur
S8 rea e
00 ke
r

S800S-K, 690 VAC
IEC

K

No. of
poles

1

S801S-K

2

S802S-K

Rated
current

10
13
16
20
25
32
40
50
63
80
100
125
10
13
16
20
25
32
40
50
63
80
100
125

s

No. of
poles

Catalog number

S801S-K10
S801S-K13
S801S-K16
S801S-K20
S801S-K25
S801S-K32
S801S-K40
S801S-K50
S801S-K63
S801S-K80
S801S-K100
S801S-K125
S802S-K10
S802S-K13
S802S-K16
S802S-K20
S802S-K25
S802S-K32
S802S-K40
S802S-K50
S802S-K63
S802S-K80
S802S-K100
S802S-K125

Tripping characteristic K

Rated
current

10
13
16
20
25
32
40
50
63
80
100
125
10
13
16
20
25
32
40
50
63
80
100
125

3

4

Catalog number

S803S-K10
S803S-K13
S803S-K16
S803S-K20
S803S-K25
S803S-K32
S803S-K40
S803S-K50
S803S-K63
S803S-K80
S803S-K100
S803S-K125
S804S-K10
S804S-K13
S804S-K16
S804S-K20
S804S-K25
S804S-K32
S804S-K40
S804S-K50
S804S-K63
S804S-K80
S804S-K100
S804S-K125

10 000

IEC
690 VAC
50 kA

1000

Inductive loads
• K Curve
• Designed for allowing higher in-rush
currents during system start up
• Example: motors, transformers

100

Accessories & technical data
S803S-K

Accessories – See page 15.52
Technical data – See page 15.76 - 15.82

10

15

seconds

1

S804S-K

0.1

0.01
1

2

3

10

20

30

multiple of rated current

Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com

e rs
ur
at ake
i
n
e
i
M it br 0
u
c S80
cir

Accessories
	S800U & S800S
UL & IEC
Shunt trip

For remote tripping of breaker, a shunt trip device can be added to the MCB. The device opens the breaker
after control voltage is applied.
Description (for field mounting, left side)

Shunt operation release 24 VAC/DC
Shunt operation release 48...130 VAC/DC
Shunt operation release 110...250 VAC/DC

Catalog number

S800-SOR24
S800-SOR130
S800-SOR250

S800-SOR

Undervoltage release

When control voltage drops below approximately 50 % of rated voltage, the UVR opens the breaker.
The breaker can not be operated unless proper control voltage is first applied to the UVR coil.
Description

Under voltage release 24...36 VAC/DC
Under voltage release 48...60 VAC/DC
Under voltage release 110...130 VAC/DC
Under voltage release 220...250 VAC/DC

Catalog number

S800-UVR36
S800-UVR60
S800-UVR130
S800-UVR250

S800-UVR

Auxiliary contacts

The auxiliary contacts will signal whether the breaker is in the ON or OFF position.
Description

Auxiliary contact

Catalog number

S800-AUX

S800-AUX

15
Bell alarm

The bell alarm includes a set of contacts that will only signal when the breaker has tripped.
Typically the contacts would be connected to an alarm or bell to signal the operator that an overcurrent trip
has occurred. The bell alarm also includes a test button for testing the alarm contacts without opening the
breaker.
Description

Bell alarm

Catalog number

S800-AUX/ALT

S800-AUX/ALT

Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com

cir Min
cu ia
it b tur
S8 rea e
00 ke
r

Accessories
	S800U & S800S
UL & IEC

s

Ring tongue adaptor
Description

Ring terminal cable connection, 40-125A

Catalog number
S800-RT2125

S800-RT2125

Rotary operating mechanism

Allows “through the door” operation.
Description

Handle mechanism

Catalog number

S800-RD

S800-RD

Description

Grey rotary handle

Catalog number

S800-RHE-H

S800-RHE-H

Description

Red rotary handle

Catalog number

S800-RHE-EM

15

S800-RHE-EM

Description

Shaft extension

Catalog number

S800-RHE-S

S800-RHE-S

UL Locking device
Description

Padlock not included

Catalog number
S800U-PLL

S800U-PLL

Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com

e rs
ur
at ake
i
n
e
i
M it br 0
u
c S80
cir

Technical data
	S800U
UL
S800U

Characteristics

K, Z

Rated operational current Ie

[A]

10...100
1...4

Pole
Rated operational voltage Ue compliant to UL 489
	 (AC)	

50/60 Hz

[V]

240

Rated ultimate short-circuit breaking capacity compliant to UL489
	 (AC)	

50/60 Hz	

240 V	

Single-pole

[kA]

30

	 (AC)	

50/60 Hz	

240 V 	

Multipole

[kA]

50

[V]

240/415

Rated operational voltage U e compliant to IEC 60947-2
	(AC)
Rated ultimate short-circuit breaking capacity I cu compliant to IEC 60947-2
	 (AC)	

50/60 Hz	

240/415 V	

Single-pole

[kA]

30

	 (AC)	

50/60 Hz	

240/415 V	

Multipole

[kA]

50

Rated service short-circuit breaking capacity I cs compliant to IEC 60947-2
	 (AC)	

50/60 Hz	

240/415 V	

Single-pole

[kA]

25

	 (AC)	

50/60 Hz	

240/415 V	

Multipole

[kA]

40

Connections C u			

10...30 A

14 – 2 AWG

				

40...100 A

8 –1 AWG

Rated frequency

50/60

Tightening torque

[Hz]

3,5 (31 in.lb.)

Protection category

[Nm]

IP40
(actuating end only)

Mounting position

any

Contacts

cadmium-free

Permissible ambient temperature
Standards

[°C]

–25...+60
UL 489
IEC 60947-2
CSA22.2 NO.5-02

Approval

cULus
File E312425

15

Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com

cir Min
cu ia
it b tur
S8 rea e
00 ke
r

Technical data
	S800U
UL
Typical internal resistances
and power losses at 25 °C
ambient temperature

Influence of ambient
temperature

s

Rated current In

Internal resistance Ri

Power loss Pv

[A]

[mΩ]

[W]

K, Z

K, Z

  10

15.2

1.5

 15

12.1

2.7

 20

 8.7

3.5

 25

 6.8

4.2

 30

 3.1

2.8

 40

 2.3

3.7

 50

 1.7

4.3

 60

 1.6

5.8

 70

 1.0

4.9

 80

 1.0

6.4

 90

 0.8

6.5

100

 0.8

8.3

Devices mounted singly (specifications in A)

S800U-K, -Z
In [A]

  10 °C

  15  ° C

  20  ° C

  25  ° C

  30  ° C

  35 ° C

  40 ° C

  45  ° C

  50 °C

  55 ° C

  60  ° C

  10

  10.9

  10.7

  10.4

  10.0

  9.6

  9.3

  9.0

  8.7

  8.4

  8.0

  7.6

 15

 16.5

 16.0

 15.6

 15.0

 14.4

 14.0

 13.5

 13.0

 12.6

 12.0

 11.4

 20

 22.0

 21.4

 20.8

 20.0

 19.2

 18.6

 18.0

 17.4

 16.8

 16.0

 15.2

 25

 27.5

 26.8

 26.0

 25.0

 24.0

 23.3

 22.5

 21.8

 21.0

 20.0

 19.0

 30

 33.1

 32.1

 31.2

 30.0

 28.8

 27.9

 27.0

 26.1

 25.2

 24.0

 22.9

 40

 44.0

 42.8

 41.6

 40.0

 38.4

 37.2

 36.0

 34.8

 33.6

 32.0

 30.9

 50

 55.1

 53.5

 52.0

 50.0

 48.0

 46.5

 45.0

 43.5

 42.0

 40.0

 38.3

 60

 66.2

 64.2

 62.4

 60.0

 57.6

 55.8

 54.0

 52.2

 50.4

 48.0

 46.0

 70

 76.9

 74.9

 72.8

 70.0

 67.2

 65.1

 63.0

 60.9

 58.8

 56.0

 53.4

 80

 88.0

 85.6

 83.2

 80.0

 76.8

 74.4

 72.0

 69.6

 67.1

 64.0

 61.6

 90

99.1

96.3

93.6

90.0

 86.4

 83.7

 81.0

 78.3

 75.6

 72.0

 69.5

100

110.5

107.0

104.0

100.0

96.0

 93.0

 90.0

87.0

83.8

80.0

77.8

Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com

15

e rs
ur
at ake
i
n
e
i
M it br 0
u
c S80
cir

Technical data
S800S
IEC

Internal resistance and power loss

Internal resistance per pole in mz, power loss per pole in W	

Type

S800S

Rated
current
A

Device series
BCDK

Power loss
BCDK

mz

W

 10
 13
 16

15.2
12.1
12.1

1.5
2.0
3.1

 20
 25
 32

8.7
6.8
3.1

3.5
4.2
3.1

 40
 50
 63

2.3
1.7
1.6

3.7
4.3
6.2

 80
100
125

1.0
0.8
0.6

6.4
8.3
9.4

Temperature derating
Max. operating current values depending on the ambient temperature for a circuit-breaker in load circuit of type B, C, D, & K characteristics.
S800S-B, -C, -D
In [A]
	10
	13
	16
	20
	25
	32
	40
	50
	63
	80
100
125

Ambient temperature T (°C/°F)
	10/50
			11.2
			14.6
			17.9
			22.4
			28.0
			35.8
			44.8
				56.0
			70.6
			89.6
112.0
140.0

	15/59
			11.0
			14.3
			17.6
			22.0
			27.5
			35.2
			44.0
			55.0
			69.3
			88.0
110.0
137.5

	20/68
			10.7
			13.9
			17.1
			21.4
			26.8
			34.2
			42.8
			53.5
			67.4
			85.6
107.0
133.8

	25/77
			10.4
			13.5
			16.6
			20.8
			26.0
			33.3
			41.6
			52.0
			65.5
			83.2
104.0
130.0

	10/50
			11.9
			15.6
			19.1
			23.9
			29.9
			38.2
			47.8
			59.7
			75.3
			95.6
119.5
149.4

	15/59
			11.6
			15.1
			18.6
			23.2
			29.1
			37.2
			46.5
			58.1
			73.2
			93.0
116.2
145.3

	20/68
			11.2
			14.6
			17.9
			22.4
			28.0
			35.8
			44.8
			56.0
			70.6
			89.6
112.0
140.0

	25/77
			11.0
			14.3
			17.6
			22.0
			27.5
			35.2
			44.0
			55.0
			69.3
			88.0
110.0
137.5

	30/86
			10.0
			13.0
			16.0
			20.0
			25.0
			32.0
			40.0
			50.0
			63.0
			80.0
100.0
125.0

	 35/95
				9.6
			12.5
			15.4
			19.2
			24.0
			30.7
			38.4
			48.0
			60.5
			76.8
			96.0
120.0

40/104
				9.3
			12.1
			14.9
			18.6
			23.3
			29.8
			37.2
			46.5
			58.6
			74.4
			93.0
116.3

45/113
				9.0
			11.7
			14.4
			18.0
			22.5
			28.8
			36.0
			45.0
			56.7
			72.0
			90.0
112.5

50/122
				8.7
			11.3
			13.9
			17.4
			21.8
			27.8
			34.8
			43.5
			54.8
			69.6
			87.0
108.8

55/131
				8.4
			10.9
			13.4
			16.8
			21.0
			26.9
			33.6
			42.0
			52.9
			67.2
			84.0
105.0

60/140
				8.0
			10.4
			12.8
			16.0
			20.0
			25.6
			32.0
			40.0
			50.4
			64.0
			80.0
100.0

50/122
				9.3
			12.1
			14.9
			18.6
			23.3
			29.8
			37.2
			46.5
			58.6
			74.4
			93
116.3

55/131
				9.0
			11.7
			14.4
			18.0
			22.5
			28.8
			36.0
			45.0
			56.7
			72.0
			90.0
112.5

60/140
				8.7
			11.3
			13.9
			17.4
			21.8
			27.8
			34.8
			43.5
			54.8
			69.6
			87.0
108.8

15
S800S-K
In [A]
	10
	13
	16
	20
	25
	32
	40
	50
	63
	80
100
125

Ambient temperature T (°C/°F)
	30/86
			10.7
			13.9
			17.1
			21.4
			26.8
			34.2
			42.8
			53.5
			67.4
			85.6
107.0
133.8

	 35/95
		 10.4
			13.5
			16.6
			20.8
			26.0
			33.3
			41.6
			52.0
			65.5
			83.2
104.0
130.0

40/104
		 10.0
			13.0
			16.0
			20.0
			25.0
			32.0
			40.0
			50.0
			63.0
			80.0
100.0
125.0

45/113
				9.6
			12.5
			15.4
			19.2
			24.0
			30.7
			38.4
			48.0
			60.5
			76.8
			96.0
120.0

Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com

cir Min
cu ia
it b tur
S8 rea e
00 ke
r

Technical data
S800S
IEC
Tripping Characteristic B

s

Tripping Characteristic C

Tripping Characteristic D

1000

1000

1000

100

100

100

10

10

10

1

1

1

0.1

seconds

10 000

seconds

10 000

seconds

10 000

0.1

0.01

0.01
1

2

3

5

10

20

0.01
1

30

2

3

5

10

20

30

multiple of rated current

multiple of rated current

Tripping Characteristic K

0.1

1

2

3

10

20

30

multiple of rated current

Tripping Characteristic Z

10 000

10 000

1000

1000

100

100

10

10

1

1

seconds

seconds

15

0.1

0.01

0.1

0.01
1

2

3

multiple of rated current

10

20

30

1

2

3

5

10

20

30

multiple of rated current

Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com

e rs
ur
at ake
i
n
e
i
M it br 0
u
c S80
cir

Technical data
S800U & S800S
Accessories

Auxiliary contact S800-AUX
S800-AUX
AC15 400/2 A-UL
AC15 240/ -UL
DC13 250/0.55 A125 V/1.1A-IEC
DC13 125 V/1.1A
DC13 60 V/2A
DC13 24 V/4A
6A
690 V
2
6 kV
3
Changeover contacts
1 x 2.5 mm2
2 x 1.5 mm2
1 Nm
5g, 20 frequency cycle
at 24 VAC/DC, 5mA
brief interrupt
<10 ms
any EN 60715
EN 60715 IP20
IP20
-25...+60 °C; -13 °F... 140 °F
-40...+70 °C; -40 °F... 158 °F
6000 switching cycles
1000 A
IEC 60068-2-27;
IEC 60068-2;
EN 61373 Cat.1/class B

Usage category

Continuous thermal current In
Rated insulation voltage Ui
Number of contacts
Surge Utest (1.2/50µs)
Degree of protection
Function of contact
Connection Cu
Tightening torque
Ensured contacts during shake test
acc. to IEC 68-2-6

AC/DC supply
Mounting on DIN top hat rail
Type of protection
Permissible ambient temperature for operations
Storage temperature
Mechanical device service life
Icu with S450E
Resistance to vibration

Undervoltage release S800-UVR
S800-UVR36
24...36
VAC/DC

Rated voltage Ue

15

S800-UVR60
48...60
VAC/DC

S800-UVR130
110...130
VAC/DC

S800-UVR250
220...250
VAC/DC

Operating range
Operating opening

35...70% Ue

Operating clothing

85% Ue
690 V

Rated insulation voltage Ui
Coil pull in consumption
Rated frequency

1 W, 14 vA

1 W, 25 vA

1 W, 41 vA

1 W, 91 vA

DC; 50/60 Hz

Protection degree
Connection Cu

3
1...35 cable

Tightening torque

min.3/ max.4 Nm

AC/DC supply

any

DIN top hat rail

EN 60715

Type of protection
Permissible ambient temperature of operations
Storage temperature
Resistance to vibration

IP20
IP40 (only actuation side)
-25...+60 °C; -13 °F... 140 °F
-40...+70 °C; -40 °F... 158 °F
IEC 60068-2-27; IEC 60068-2; EN61373 Cat.1/class B

Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com

cir Min
cu ia
it b tur
S8 rea e
00 ke
r

Technical data
S800U & S800S
Accessories

s

Combined auxiliary and bell alarm
Usage category

Continuous thermal current In
Rated insulation voltage Ui
Number of contacts
Surge Utest (1.2/50µs)
Degree of protection
Function of contact
Connection Cu
Tightening torque
Ensured contacts during shake test
acc. to IEC 68-2-6

AC/DC supply
Mounting on DIN top hat rail
Type of protection
Permissible ambient temperature for operations
Storage temperature
mech. Device service life
Icu with S450E
Resistance to vibration

AC15 400/2A-UL
AC15 240/6A-UL
DC13 250/0.55A125V/1.1A-IEC
DC13 125V/1.1A-IEC
DC13 60V/2A
DC13 24V/4A
6A
690 V
2 (1x AUX, 1 x AUX/ALT)
6 kV
3
Changeover contacts
1 x 2.5 mm2
2 x 1.5 mm2
1 Nm
5g, 20 frequency cycle
5...150...5Hz
at 24VAC/DC, 5mA
brief interrupt
<10ms
any EN 60715
EN 60715
IP20
-25 °C... 60 °C; -13 °F... 140 °F
-40 °C... 70 °C; -40 °F... 150 °F
6000 switching cycles
1000 A
IEC 60068-2-27;
IEC 60068-2;
EN 61373 Cat.1/class B

Shunt operation release – S800-SOR
Rated voltage Ue
Operating range
Rated insulation voltage Ui
Coil pull in consumption
Rated frequency
Degree of protection
Connection Cu
Tightening torque
AC/DC supply
DIN top hat rail
Type of protection
Permissible ambient temperature of operations
Storage temperature
Resistance to vibration

S800-SOR24
24 VAC/DC

19.2 W/vA

S800-SOR130
S800-SOR250
48...130 VAC/DC
110...250 VAC/DC
70... 110% Ue
690 V
On request
DC; 50/60 Hz
3
1...35 AWG
min.3/ max.4 Nm
any
EN 60715
IP20; IP40 (only actuation side)
-25 °C... 60 °C; -13 °F... 140 °F

S800-SOR400
220...250

-40 °C... 70 °C; -40 °F... 158 °F
IEC 60068-2-27; IEC 60068-2; EN61373 Cat.1/class B	

Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com

15

e rs
ur
at ake
i
n
e
i
M it br 0
u
c S80
cir

Technical data
Backup
S800S - S200 @ 230/400 V
E.

Char.
Icu [kA]

L.

S200

B

6

In [A]
6
10
13
16
20
25
32
40
50
63

25
50
50
50
50

32
50
50
50
50
50

40
50
50
50
50
50
50

S800S
B, C, D, K
50
50 63
50 50
50 50
50 50
50 50
50 50
50 50
50 50
50

E.
Char.
Icu [kA]

L.
80
50
50
50
50
50
50
50
50
50

100 125
50 50
50 50
50 50
50 50
50 50
50 50
50 50
50 50
50 50
50 50

25
S200P

B
15

In [A]
6…16
20
25
32
40
50
63

25
50

32
50
50

40
50
50
50

E.
Char.
Icu [kA]

L.
E.
Char.
Icu [kA]

L.

[A]
0.5…6
8
10
13
16
20
25
32
40
50
63
In

S200

C

6

25
50
50
50
50
50

32
50
50
50
50
50
50

40
50
50
50
50
50
50
50

S800S
B, C, D, K
50
50 63
50 50
50 50
50 50
50 50
50 50
50 50
50 50
50 50
50

25
80
50
50
50
50
50
50
50
50
50
50

100 125
50 50
50 50
50 50
50 50
50 50
50 50
50 50
50 50
50 50
50 50
50 50

S200P

C
15

25
In [A]
0.5…16 50
20
25
32
40
50
63

32
50
50

40
50
50
50

S800S
B, C, D, K
50
50 63
50 50
50 50
50 50
50 50
50

S800S
B, C, D, K
50
50 63
50 50
50 50
50 50
50 50
50

80
50
50
50
50
50
50

100 125
50 50
50 50
50 50
50 50
50 50
50 50
50 50

80
50
50
50
50
50
50

100 125
50 50
50 50
50 50
50 50
50 50
50 50
50 50

LEGEND
E. = supply side
L. = load side
Back-up limit values are specified in kA

15

Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com

cir Min
cu ia
it b tur
S8 rea e
00 ke
r

Technical data
Selectivity
S800S - S200 @ 230/400 V
E.
Char.
Icu [kA]

L.

S200

B

6

In [A]
6
10
13
16
20
25
32
40
50
63

25

32

40
0.4

E.
Char.
Icu [kA]

L.

S200

C

6

In [A]
0.5
1
1.6
2
3
4
6
8
10
13
16
20
25
32
40
50
63

25
T
3.3
0.6
0.4

32
T
T
1.3
0.7
0.4
0.4

40
T
T
T
1.3
0.6
0.6
0.4

S800S
B
50
50
63
0.5 0.7
0.4 0.6
0.5

S800S
B
50
50
63
T
T
T
T
T
T
T
T
0.7 1.1
0.7
1
0.5 0.7
0.4 0.6
0.4 0.6
0.5

s

E.
Char.
Icu [kA]

L.
80
1
0.7
0.7
0.7

80
T
T
T
T
2.6
1.7
1
0.7
0.7
0.7
0.7

100
1.5
1
0.9
0.9
0.9
0.9
0.8
0.8

100
T
T
T
T
T
3.1
1.5
1
1
0.9
0.9
0.9
0.9
0.8
0.8

125
2.6
1.4
1.3
1.3
1.3
1.3
1.1
1.1
1
0.9

125
T
T
T
T
T
T
2.6
1.4
1.4
1.3
1.3
1.3
1.3
1.1
1.1
1
0.9

S200

D

6

In [A]
0.5
1
1.6
2
3
4
6
8
10
13
16
20
25
32
40
50
63

25
T
0.8
0.5
0.3

32
T
4.5
1
0.5
0.4
0.4

40
T
T
2.3
0.7
0.5
0.4

E.
Char.
Icu [kA]

L.

S200

K

6

In [A]
0.5
1
1.6
2
3
4
6
8
10
13
16
20
25
32
40
50
63

25
T
0.8
0.5
0.3

32
T
5
1
0.5
0.4
0.4

40
T
T
2.1
0.7
0.5
0.4

S800S
B
50
50
63
T
T
T
T
T
T
2.3
T
0.7 1.2
0.7
1
0.6 0.8
0.7

S800S
B
50
50
63
T
T
T
T
T
T
2.1
T
0.7 1.2
0.7
1
0.6 0.8
0.7

80
T
T
T
T
2.5
1.7
1.2
0.9
0.9

100
T
T
T
T
T
3
2
1.3
1.3
1

125
T
T
T
T
T
T
3.6
2
2
1.5
1.5

80
T
T
T
T
2.5
1.7
1.2
0.9
0.9

100
T
T
T
T
T
3
2
1.3
1.3
1

125
T
T
T
T
T
T
3.6
2
2
1.5
1.5

15
LEGEND
E. = supply side
L. = load side
Back-up limit values are specified in kA

Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com

e rs
ur
at ake
i
n
e
i
M it br 0
u
c S80
cir

Technical data
Selectivity
S800S - S200 @ 230/400 V
E.

Char.
Icu [kA]

L.

S200

B

6

In [A]
6
10
13
16
20
25
32
40
50
63

25

32
0.4
0.3
0.3
0.3

40
0.5
0.4
0.4
0.4
0.4
0.4

S800S
C
50
50
63
0.7 0.9
0.5 0.7
0.5 0.7
0.5 0.7
0.5 0.7
0.5 0.7
0.5 0.6
0.6

E.
80
1.4
0.9
0.9
0.9
0.9
0.9
0.8
0.8
0.7

100
2.4
1.3
1.3
1.3
1.2
1.2
1
1
0.9
0.9

125
4.8
2
1.9
1.9
1.8
1.8
1.4
1.4
1.3
1.2

Char.
Icu

L.

S200
E.
Char.
Icu [kA]

L.

S200

C

6

In [A]
0.5
1
1.6
2
3
4
6
8
10
13
16
20
25
32
40
50
63

25
T
T
0.6
0.5
0.3
0.3

32
T
T
T
1
0.5
0.4
0.4
0.3
0.3
0.3
0.3

40
T
T
T
T
0.7
0.7
0.5
0.4
0.4
0.4
0.4
0.4
0.4

S800S
C
50
50
63
T
T
T
T
T
T
T
T
1.2 2.1
1
1.5
0.7 0.9
0.5 0.7
0.5 0.7
0.5 0.7
0.5 0.7
0.5 0.7
0.5 0.7
0.5 0.6
0.6

80
T
T
T
T
T
2.6
1.4
0.9
0.9
0.9
0.9
0.9
0.9
0.8
0.8
0.7

100
T
T
T
T
T
T
2.4
1.3
1.3
1.3
1.3
1.2
1.2
1
1
0.9
0.9

125
T
T
T
T
T
T
4.8
2
2
1.9
1.9
1.8
1.8
1.4
1.4
1.3
1.2

D

[kA]

6

In [A]
0.5
1
1.6
2
3
4
6
8
10
13
16
20
25
32
40
50
63

25
T
2.1
0.8
0.4
0.3
0.3

32
T
T
2.3
0.7
0.5
0.4
0.4

40
T
T
T
2.3
0.7
0.7
0.6
0.5

E.
Char.
Icu [kA]

L.

S200

15

K

6

In [A]
0.5
1
1.6
2
3
4
6
8
10
13
16
20
25
32
40
50
63

25
T
2.1
0.8
0.4
0.3
0.3

32
T
T
2.3
0.7
0.5
0.4
0.4

40
T
T
T
2.3
0.7
0.7
0.6
0.5

S800S
C
50
50
63
T
T
T
T
T
T
T
T
1.2 2.2
1
1.4
0.8 1.1
0.7 0.9
0.7 0.9
0.7

S800S
C
50
50
63
T
T
T
T
T
T
T
T
1.2 2.2
1
1.4
0.8 1.1
0.7 0.9
0.7 0.9
0.7

80
T
T
T
T
T
2.6
1.8
1.2
1.2
1
1

100
T
T
T
T
T
T
3.2
1.8
1.8
1.4
1.4
1

125
T
T
T
T
T
T
T
2.8
2.8
2
2
1.4
1.4

80
T
T
T
T
T
2.6
1.8
1.2
1.2
1
1

100
T
T
T
T
T
T
3.2
1.8
1.8
1.4
1.4
1

125
T
T
T
T
T
T
T
2.8
2.8
2
2
1.4
1.4

LEGEND
E. = supply side
L. = load side
Back-up limit values are specified in kA

Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com

cir Min
cu ia
it b tur
S8 rea e
00 ke
r

Technical data
Selectivity
S800S - S200 @ 230/400 V
E.
Char.
Icu [kA]

L.

S200

B

6

In [A]
6
10
13
16
20
25
32
40
50
63

25
0.5
0.4
0.4

32
1
0.6
0.6
0.6

40
1.2
0.8
0.8
0.8
0.8
0.8

E.
Char.
Icu [kA]

L.

S200

C

6

In [A]
0.5
1
1.6
2
3
4
6
8
10
13
16
20
25
32
40
50
63

25
T
T
T
T
0.7
0.7
0.5
0.4
0.4
0.4

32
T
T
T
T
2.2
1.3
1
0.6
0.6
0.6
0.6

40
T
T
T
T
4.4
2.2
1.2
0.8
0.8
0.8
0.8
0.8
0.8

S800S
D
50
50
63
2
2.8
1.1 1.4
1.1 1.4
1.1 1.4
1.1 1.3
1.1 1.3
0.9 1.1
1.1

S800S
D
50
50
63
T
T
T
T
T
T
T
T
T
T
4.4
T
2
2.8
1.1 1.4
1.1 1.4
1.1 1.4
1.1 1.4
1.1 1.3
1.1 1.3
0.9 1.1
1.1

s

E.
Char.
Icu [kA]

L.
80
T
2.8
2.5
2.5
2.3
2.3
1.9
1.9
1.5

100
T
3.9
3.3
3.3
3
3
2.4
2.4
1.9
1.7

125
T
T
T
5.6
4.7
4.7
3.7
3.7
2.3
2.3

80
T
T
T
T
T
T
T
2.8
2.8
2.5
2.5
2.3
2.3
1.9
1.9
1.5

100
T
T
T
T
T
T
T
3.9
3.9
3.3
3.3
3
3
2.4
2.4
1.9
1.7

125
T
T
T
T
T
T
T
T
T
5.6
5.6
4.7
4.7
3.7
3.7
2.3
2.3

S200

D

6

In [A]
0.5
1
1.6
2
3
4
6
8
10
13
16
20
25
32
40
50
63

25
T
T
T
2.3
0.7
0.7
0.6
0.5
0.5

32
T
T
T
T
1.3
1
0.8
0.7
0.7
0.6

40
T
T
T
T
4.4
2.2
1.5
1.1
1.1
0.9
0.9

E.
Char.
Icu [kA]

L.

S200

K

6

In [A]
0.5
1
1.6
2
3
4
6
8
10
13
16
20
25
32
40
50
63

25
T
T
T
2.3
0.7
0.7
0.6
0.5
0.5

32
T
T
T
T
1.3
1
0.8
0.7
0.7
0.6

40
T
T
T
T
4.4
2.2
1.5
1.1
1.1
0.9
0.9

S800S
D
50
50
63
T
T
T
T
T
T
T
T
T
T
4.4
T
2.5 3.6
1.5
2
1.5
2
1.2 1.5
1.2 1.5
0.9 1.1
1.1

S800S
D
50
50
63
T
T
T
T
T
T
T
T
T
T
4.4
T
2.5 3.6
1.5
2
1.5
2
1.2 1.5
1.2 1.5
0.9 1.1
1.1

80
T
T
T
T
T
T
T
4
4
2.6
2.6
1.8
1.8
1.7

100
T
T
T
T
T
T
T
5.5
5.5
3.4
3.4
2.2
2.2
2
1.9

125
T
T
T
T
T
T
T
T
T
5.2
5.2
3.2
3.2
2.9
2.6
2.2

80
T
T
T
T
T
T
T
4
4
2.6
2.6
1.8
1.8
1.7

100
T
T
T
T
T
T
T
5.5
5.5
3.4
3.4
2.2
2.2
2
1.9

125
T
T
T
T
T
T
T
T
T
5.2
5.2
3.2
3.2
2.9
2.6
2.2

LEGEND
E. = supply side
L. = load side
Back-up limit values are specified in kA

Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com

15

e rs
ur
at ake
i
n
e
i
M it br 0
u
c S80
cir

Technical data
Selectivity
S800S - S200 @ 230/400 V
E.

Char.
Icu [kA]

L.

25
S200P

B

15

In [A]
6
10
13
16
20
25
32
40
50
63

25

32

40
0.4

E.
Char.
Icu

L.

[kA]

25
S200P

C

15

In [A]
0.5
1
1.6
2
3
4
6
8
10
13
16
20
25
32
40
50
63

25
T
3.3
0.6
0.4

32
T
T
1.3
0.7

40
T
T
T
1.2
0.6
0.6
0.4

E.
Char.
Icu [kA]

L.

15
25
S200P

K

15

In [A]
0.2
0.3
0.5
0.75
1
1.6
2
3
4
6
8
10
13
16
20
25
32
40
50
63

25
T
T
T
T
0.8
0.5
0.3

32
T
T
T
T
5
1
0.5
0.4
0.4

40
T
T
T
T
T
2.3
0.7
0.5
0.4

S800S
B
50
50
63
0.5 0.7
0.4 0.6
0.5

S800S
B
50
50
63
T
T
T
T
T
T
T
T
0.7 1.1
0.7
1
0.5 0.7
0.4 0.6
0.4 0.6
0.5

S800S
B
50
50
63
T
T
T
T
T
T
T
T
T
T
T
T
2.1
T
0.7 1.2
0.7
1
0.6 0.8
0.7

E.
Char.
Icu [kA]

L.
80
1
0.7
0.7
0.7

100
1.5
1
0.9
0.9
0.9
0.9
0.8
0.8

125
2.6
1.4
1.3
1.3
1.3
1.3
1.1
1.1
1
0.9

25
S200P

B

15

In [A]
6
10
13
16
20
25
32
40
50
63

25

32

40
0.4

E.
Char.
L.
80
T
T
T
T
2.6
1.7
1
0.7
0.7
0.7
0.7

100
T
T
T
T
8.8
3.1
1.5
1
1
0.9
0.9
0.9
0.9
0.8
0.8

125
T
T
T
T
T
7
2.6
1.4
1.4
1.3
1.3
1.3
1.3
1.1
1.1
1
0.9

Icu

[kA]

25
S200P

C

15

In [A]
0.5
1
1.6
2
3
4
6
8
10
13
16
20
25
32
40
50
63

25
T
3.3
0.6
0.4

32
T
T
1.3
0.7
0.4
0.4

40
T
T
T
1.3
0.6
0.6
0.4

E.
Char.
Icu [kA]

L.
80
T
T
T
T
T
T
T
2.5
1.7
1.2
0.9
0.9

100
T
T
T
T
T
T
T
8.6
3
2
1.3
1.3
1

125
T
T
T
T
T
T
T
T
7.7
3.6
2
2
1.5
1.5

25
S200P

K

15

In [A]
0.2
0.3
0.5
0.75
1
1.6
2
3
4
6
8
10
13
16
20
25
32
40
50
63

25
T
T
T
T
0.8
0.5
0.3

32
T
T
T
T
5
1
0.5
0.4
0.4

40
T
T
T
T
T
2.3
0.7
0.5
0.4

S800S
C
50
50
63
0.5 0.7
0.4 0.6
0.5

S800S
C
50
50
63
T
T
T
T
T
T
T
T
0.7 1.1
0.7
1
0.5 0.7
0.4 0.6
0.4 0.6
0.5

S800S
C
50
50
63
T
T
T
T
T
T
T
T
T
T
T
T
2.3
T
0.7 1.2
0.7
1
0.6 0.8
0.7

80
1
0.7
0.7
0.7

100
1.5
1
0.9
0.9
0.9
0.9
0.8
0.8

125
2.6
1.4
1.3
1.3
1.3
1.3
1.1
1.1
1
0.9

80
T
T
T
T
2.6
1.7
1
0.7
0.7
0.7
0.7

100
T
T
T
T
8.8
3.1
1.5
1
1
0.9
0.9
0.9
0.9
0.8
0.8

125
T
T
T
T
T
7
2.6
1.4
1.4
1.3
1.3
1.3
1.3
1.1
1.1
1
0.9

80
T
T
T
T
T
T
T
2.5
1.7
1.2
0.9
0.9

100
T
T
T
T
T
T
T
8.6
3
2
1.3
1.3
1

125
T
T
T
T
T
T
T
T
7.7
3.6
2
2
1.5
1.5

LEGEND
E. = supply side
L. = load side
Back-up limit values are specified in kA

Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com

cir Min
cu ia
it b tur
S8 rea e
00 ke
r

Technical data
Selectivity
S800S - S200P @ 230/400 V
E.
Char.
Icu [kA]

L.

25
S200P

B

15

In [A]
6
10
13
16
20
25
32
40
50
63

25
0.5
0.4
0.4

32
1
0.6
0.6
0.6

40
1.2
0.8
0.8
0.8
0.8
0.8

S800S
D
50
50
63
2
2.8
1.1 1.4
1.1 1.4
1.1 1.4
1.1 1.3
1.1 1.3
0.9 1.1
1.1

E.
Char.
80
9.9
2.8
2.5
2.5
2.3
2.3
1.9
1.9
1.5

100
21.3
3.9
3.3
3.3
3
3
2.4
2.4
1.9
1.7

125
T
7.4
5.6
5.6
4.7
4.7
3.7
3.7
2.3
2.3

E.
Icu [kA]

L.

25
S200P

C

15

In [A]
0.5
1
1.6
2
3
4
6
8
10
13
16
20
25
32
40
50
63

25
T
T
T
T
0.7
0.7
0.5
0.4
0.4
0.4

32
T
T
T
T
2.2
1.3
1
0.6
0.6
0.6
0.6

40
T
T
T
T
4.4
2.2
1.2
0.8
0.8
0.8
0.8
0.8
0.8

S800S
D
50
50
63
T
T
T
T
T
T
T
T
T
T
4.4 7.7
2
2.8
1.1 1.4
1.1 1.4
1.1 1.4
1.1 1.4
1.1 1.3
1.1 1.3
0.9 1.1
1.1

80
T
T
T
T
T
T
9.9
2.8
2.8
2.5
2.5
2.3
2.3
1.9
1.9
1.5

100
T
T
T
T
T
T
22
3.9
3.9
3.3
3.3
3
3
2.4
2.4
1.9
1.7

Icu [kA]

L.

25
S200P

Char.

s

125
T
T
T
T
T
T
T
7.4
7.4
5.6
5.6
4.7
4.7
3.7
3.7
2.3
2.3

K

15

In [A]
0.2
0.3
0.5
0.75
1
1.6
2
3
4
6
8
10
13
16
20
25
32
40
50
63

25
T
T
T
T
T
T
2.3
0.7
0.7
0.6
0.5
0.5

32
T
T
T
T
T
T
T
1.3
1
0.8
0.7
0.7
0.6

40
T
T
T
T
T
T
T
4.4
2.2
1.5
1.1
1.1
0.9
0.9

S800S
D
50
50
63
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
4.4 7.7
2.5 3.6
1.5
2
1.5
2
1.2 1.5
1.2 1.5
0.9 1.1

80 100 125
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
12.1 24.2
T
4
5.5 9.9
4
5.5 9.9
2.6 3.4 5.2
2.6 3.4 5.2
1.8 2.2 3.2
1.8 2.2 3.2
1.7
2
2.9
1.9 2.6
2.2

LEGEND
E. = supply side
L. = load side
Back-up limit values are specified in kA

15

Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com

e rs
ur
at ake
i
n
e
i
M it br 0
u
c S80
cir

Technical data
Selectivity
S800S - S280 @ 230/400 V
E.

Char.
L.

Icu [kA]
10

25
S280

B
15
10

In [A]
6
10
13
16
20
25
32
40
50
63

25
50
50
50
50

32
50
50
50
50
50

40
50
50
50
50
50
50

E.
Icu [kA]

10

S280

C

25

15
10

S280

K, Z

25

15
10

125
50
16
16
16
16
16
16
16
16
16

Icu [kA]

S400E

B

6

In [A]
6
10
13
16
20
25
32
40
50
63

25
50
50
50
50

32
50
50
50
50
50

40
50
50
50
50
50
50

E.
L.

40
50
50
50
50
50

50
50
50
50
25
25

63
50
50
50
20
20

80
50
50
50
16
16

100
50
50
50
16
16

125
50
50
50
16
16

13
16
20
25
32
40
50
63

50
50

50
50
50

50
50
50
50

25
25
25
25
25

20
20
20
20
20
20

16
16
16
16
16
16
16

16
16
16
16
16
16
16
16

16
16
16
16
16
16
16
16

80
50
50
50
16
16

100
50
50
50
16
16

125
50
50
50
16
16

In [A]
3
4
6
8
10

25
50
50
50
50
50

32
50
50
50
50
50

40
50
50
50
50
50

S800S
B, C, D, K
50
50
63
50
50
50
50
50
50
25
20
25
20

13

50

50

50

25

20

16

16

16

16
20
25
32
40
50
63

50

50
50

50
50
50

25
25
25
25

20
20
20
20
20

16
16
16
16
16
16

16
16
16
16
16
16
16

16
16
16
16
16
16
16

Icu [kA]
In [A]
0.5…6
8
10
13
16

S400E

C

6

20
25
32
40
50
63

S800S
B, C, D, K
50
50
63
50
50
50
50
50
50
50
50
50
50
50
50
50
50
50

80
50
50
50
50
50
50
50
50
50

100
50
50
50
50
50
50
50
50
50
50

125
50
50
50
50
50
50
50
50
50
50

S800S
B, C, D, K
50

Char.

32
50
50
50
50
50

Icu [kA]

10

100
50
16
16
16
16
16
16
16
16
16

25
50
50
50
50
50

E.

15

L.
80
50
16
16
16
16
16
16
16
16

In [A]
3
4
6
8
10

Char.
L.

E.
Char.

S800S
B, C, D, K
50

Char.
L.

S800S
B, C, D, K
50
50
63
50
50
25
20
25
20
25
20
25
20
25
20
25
20
20

25
50
50
50
50
50

32
50
50
50
50
50

40
50
50
50
50
50

50
50
50
50
50
50

63
50
50
50
50
50

80
50
50
50
50
50

100
50
50
50
50
50

125
50
50
50
50
50

50

50
50

50
50
50

50
50
50
50

50
50
50
50
50

50
50
50
50
50
50

50
50
50
50
50
50

LEGEND
E. = supply side
L. = load side
Back-up limit values are specified in kA

Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com

cir Min
cu ia
it b tur
S8 rea e
00 ke
r

Approximate dimensions
S800U & S800S
UL & IEC

s

Dimension drawings in mm

S800-SOR & S800-UVR

S800S & S800U
106

6

82.5

79.5

6

26.5

82.5

76.5

53

76.5

46

46

45

95

45

95

35

95
2CCC413010Z0001

35

45

26.5

1P

2P

3P

4P

S800-AUX

S800-AUX/ALT
9
9

6

6

82.5

82.5

76.5

76.5

46

46

T

2CCC413018Z0001

95

RT

2CCC413017Z0001

35

45

35

T

15

S800-RD & S800-RHE
81

67

76

48

76

max. 500mm

Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com

cir Min
cu ia
it b tur
S5 rea e
00 ke
r

S500 UL 1077 Series

Miniature circuit breakers

S500 Series
UL 1077

s

Description

Features

The S500 high performance MCB offers
a compact solution to circuit protection.
The S500 devices are UL tested current
limiting and DIN rail mounted. The S500
is available with application-specific trip
characteristics to provide maximum circuit
protection.

•	
•	
•	
•	
•	
•	
•	
•	
	
•	
•	
•	
•	

The breakers offer thermal-magnetic
trip protection according to B and K
characteristics.
For the worldwide market, the breakers
carry CSA, IEC, CE and many other
agency approvals.

High breaking capacity
Fast breaking time (2.3 - 2.5 ms)
Adjustable trip unit
DIN rail mounting
Finger safe terminals
Multi-functional terminals
Wide range of accessories
UL 1077 recognized 600 VAC and
600 VDC versions
UL1077 AC adjustable K
UL1077 DC adjustable B, K
UL File # E167556
IEC #E60497-2

S500
Amperage
Voltage

S500UC

0.1 – 45 A

0.1 – 63 A

UL: 600Y/277 VAC
IEC: 690 VAC

UL: 250 VDC per pole (600 VDC for 4P)
IEC: 250 VDC per pole (750 VDC for 4P)

1, 2, 3

1, 2, 3, 4

Trip characteristics

K

B, K

Interrupting ratings

Up to 30 kA : UL 1077
Up to 30 kA: CSA C22.2

30 kA : UL 1077
30 kA: CSA C22.2

Auxiliary contacts

Yes

Yes

Bell alarm

Yes

Yes

Shunt trip

No

No

Undervoltage release

No

No

Bus bar

Yes

Yes

Poles

Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com

15

re s
tu ker
a
i
in ea
M it br 0
cu S50
cir

K

S500-K, UL 600Y/277 VAC / IEC 690 VAC
Supplemental protection
UL 1077, CSA 22.2, IEC
No. of
poles

1
S501-K

S502-K

2

S503-K

Catalog number

	 0.1	–	 0.15
	0.14	–	 0.21
	 0.2	–	 0.3
	0.28	–	 0.42
	0.38	–	 0.58
	0.53	–	 0.8
	0.73	–	 1.1
	 1	–	 1.5
	 1.4	–	 2.1
	 2	–	 3
	 2.8	–	 4.2
	 3.8	–	 5.8
	 5.3	–	 8
	 7.3	–	 11
	 10	–	 15
	 14	–	 20
	 18	–	 26
	 23	–	 32
	 29	–	 37
	 34	–	 41
	 38	–	 45
	 0.1	–	 0.15
	0.14	–	 0.21
	 0.2	–	 0.3
	0.28	–	 0.42
	0.38	–	 0.58
	0.53	–	 0.8
	0.73	–	 1.1
	 1	–	 1.5
	 1.4	–	 2.1
	 2	–	 3
	 2.8	–	 4.2
	 3.8	–	 5.8
	 5.3	–	 8
	 7.3	–	 11
	 10	–	 15
	 14	–	 20
	 18	–	 26
	 23	–	 32
	 29	–	 37
	 34	–	 41
	 38	–	 45

S501-K0.15
S501-K0.21
S501-K0.3
S501-K0.42
S501-K0.58
S501-K0.8
S501-K1.1
S501-K1.5
S501-K2.1
S501-K3
S501-K4.2
S501-K5.8
S501-K8
S501-K11
S501-K15
S501-K20
S501-K26
S501-K32
S501-K37
S501-K41
S501-K45
S502-K0.15
S502-K0.21
S502-K0.3
S502-K0.42
S502-K0.58
S502-K0.8
S502-K1.1
S502-K1.5
S502-K2.1
S502-K3
S502-K4.2
S502-K5.8
S502-K8
S502-K11
S502-K15
S502-K20
S502-K26
S502-K32
S502-K37
S502-K41
S502-K45

No. of
poles

Rated
current

Catalog number

	 0.1	–	 0.15
	0.14	–	 0.21
	 0.2	–	 0.3
	0.28	–	 0.42
	0.38	–	 0.58
	0.53	–	 0.8
	0.73	–	 1.1
	 1	–	 1.5
	 1.4	–	 2.1
	 2	–	 3
	 2.8	–	 4.2
	 3.8	–	 5.8
	 5.3	–	 8
	 7.3	–	 11
	 10	–	 15
	 14	–	 20
	 18	–	 26
	 23	–	 32
	 29	–	 37
	 34	–	 41
	 38	–	 45

3

S503-K0.15
S503-K0.21
S503-K0.3
S503-K0.42
S503-K0.58
S503-K0.8
S503-K1.1
S503-K1.5
S503-K2.1
S503-K3
S503-K4.2
S503-K5.8
S503-K8
S503-K11
S503-K15
S503-K20
S503-K26
S503-K32
S503-K37
S503-K41
S503-K45

10,000

Tripping characteristic K
UL 1077

IEC

600 VAC
Up to 30 kA

690 VAC
Up to 30 kA

5000
1000
500

Inductive loads
• K Curve
• Designed for allowing higher in-rush
currents during system start up
• Example: motors, transformers

100
50
10
5

Accessories & technical data

Accessories – See page 15.71
Technical data – See page 15.76 - 82
seconds

15

Rated
current

1
0.5
AC
0.1
0.05
0.01
1

2

3

5

8 10 12

20 30

multiple of rated current

Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com

cir Min
cu ia
it b tur
S5 rea e
00 ke
r

S500UC-B, 250 VDC per pole (600 VDC 4P)
UL/IEC (750 VDC 4P)
Supplemental protectors, UL1077, CSA 22.2, IEC

B

No. of
poles

1

S501UC-B

2

Rated
current

Catalog number

6
10
13
16
20
25
32
40
50
63
6
10
13
16
20
25
32
40
50
63

No. of
poles

S501UC-B6
S501UC-B10
S501UC-B13
S501UC-B16
S501UC-B20
S501UC-B25
S501UC-B32
S501UC-B40
S501UC-B50
S501UC-B63
S502UC-B6
S502UC-B10
S502UC-B13
S502UC-B16
S502UC-B20
S502UC-B25
S502UC-B32
S502UC-B40
S502UC-B50
S502UC-B63

Tripping characteristic B

Catalog number

6
10
13
16
20
25
32
40
50
63
6
10
13
16
20
25
32
40
50
63

3

4

S503UC-B6
S503UC-B10
S503UC-B13
S503UC-B16
S503UC-B20
S503UC-B25
S503UC-B32
S503UC-B40
S503UC-B50
S503UC-B63
S504UC-B6
S504UC-B10
S504UC-B13
S504UC-B16
S504UC-B20
S504UC-B25
S504UC-B32
S504UC-B40
S504UC-B50
S504UC-B63

10,000

UL 1077

IEC

250 VDC per pole
(600 VDC 4P)
30 kA

250 VDC per pole
(750 VDC 4P)
30 kA

5000
1000
500

S502UC-B

Inductive loads

100
50

• B Curve
• Designed for allowing higher in-rush
currents during system start up
• Example: motors, transformers

10
5

Accessories & technical data

seconds

Accessories – See page 15.71
Technical data – See page 15.76 - 82
S503UC-B

Rated
current

s

1
0.5
DC
0.1
0.05

15

0.01
1

2

3

5

7 10

20 30

multiple of rated current

S504UC-B

Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com

re s
tu ker
a
i
in ea
M it br 0
cu S50
cir

K

S500UC-K, 250 VDC per pole (600 VDC 4P)
UL/IEC (750 VDC 4P)
Supplemental protectors, UL1077, CSA 22.2, IEC
No. of
poles

1
S501UC-K

S502UC-K

2

S503UC-K

Rated
current

	 0.1	–	 0.15
	0.14	–	 0.21
	 0.2	–	 0.3
	0.28	–	 0.42
	0.38	–	 0.58
	0.53	–	 0.8
	0.73	–	 1.1
	 1	–	 1.5
	 1.4	–	 2.1
	 2	–	 3
	 2.8	–	 4.2
	 3.8	–	 5.8
	 5.3	–	 8
	 7.3	–	 11
	 10	–	 15
	 14	–	 20
	 18	–	 26
	 23	–	 32
	 29	–	 37
	 34	–	 41
	 38	–	 45
	 0.1	–	 0.15
	0.14	–	 0.21
	 0.2	–	 0.3
	0.28	–	 0.42
	0.38	–	 0.58
	0.53	–	 0.8
	0.73	–	 1.1
	 1	–	 1.5
	 1.4	–	 2.1
	 2	–	 3
	 2.8	–	 4.2
	 3.8	–	 5.8
	 5.3	–	 8
	 7.3	–	 11
	 10	–	 15
	 14	–	 20
	 18	–	 26
	 23	–	 32
	 29	–	 37
	 34	–	 41
	 38	–	 45

Catalog number

S501UC-K0.15
S501UC-K0.21
S501UC-K0.3
S501UC-K0.42
S501UC-K0.58
S501UC-K0.8
S501UC-K1.1
S501UC-K1.5
S501UC-K2.1
S501UC-K3
S501UC-K4.2
S501UC-K5.8
S501UC-K8
S501UC-K11
S501UC-K15
S501UC-K20
S501UC-K26
S501UC-K32
S501UC-K37
S501UC-K41
S501UC-K45
S502UC-K0.15
S502UC-K0.21
S502UC-K0.3
S502UC-K0.42
S502UC-K0.58
S502UC-K0.8
S502UC-K1.1
S502UC-K1.5
S502UC-K2.1
S502UC-K3
S502UC-K4.2
S502UC-K5.8
S502UC-K8
S502UC-K11
S502UC-K15
S502UC-K20
S502UC-K26
S502UC-K32
S502UC-K37
S502UC-K41
S502UC-K45

Tripping characteristic K

15

S504UC-K

No. of
poles

Rated
current

Catalog number

	 0.1	–	 0.15
	0.14	–	 0.21
	 0.2	–	 0.3
	0.28	–	 0.42
	0.38	–	 0.58
	0.53	–	 0.8
	0.73	–	 1.1
	 1	–	 1.5
	 1.4	–	 2.1
	 2	–	 3
	 2.8	–	 4.2
	 3.8	–	 5.8
	 5.3	–	 8
	 7.3	–	 11
	 10	–	 15
	 14	–	 20
	 18	–	 26
	 23	–	 32
	 29	–	 37
	 34	–	 41
	 38	–	 45
	 0.1	–	 0.15
	0.14	–	 0.21
	 0.2	–	 0.3
	0.28	–	 0.42
	0.38	–	 0.58
	0.53	–	 0.8
	0.73	–	 1.1
	 1	–	 1.5
	 1.4	–	 2.1
	 2	–	 3
	 2.8	–	 4.2
	 3.8	–	 5.8
	 5.3	–	 8
	 7.3	–	 11
	 10	–	 15
	 14	–	 20
	 18	–	 26
	 23	–	 32
	 29	–	 37
	 34	–	 41
	 38	–	 45

3

4

S503UC-K0.15
S503UC-K0.21
S503UC-K0.3
S503UC-K0.42
S503UC-K0.58
S503UC-K0.8
S503UC-K1.1
S503UC-K1.5
S503UC-K2.1
S503UC-K3
S503UC-K4.2
S503UC-K5.8
S503UC-K8
S503UC-K11
S503UC-K15
S503UC-K20
S503UC-K26
S503UC-K32
S503UC-K37
S503UC-K41
S503UC-K45
S504UC-K0.15
S504UC-K0.21
S504UC-K0.3
S504UC-K0.42
S504UC-K0.58
S504UC-K0.8
S504UC-K1.1
S504UC-K1.5
S504UC-K2.1
S504UC-K3
S504UC-K4.2
S504UC-K5.8
S504UC-K8
S504UC-K11
S504UC-K15
S504UC-K20
S504UC-K26
S504UC-K32
S504UC-K37
S504UC-K41
S504UC-K45

10,000

UL 1077

IEC

250 VDC per pole
(600 VDC 4P)
30 kA

250 VDC per pole
(750 VDC 4P)
30 kA

5000
1000
500

Inductive loads
• K Curve
• Designed for allowing higher in-rush
currents during system start up
• Example: motors, transformers

100
50
10
5

Accessories & technical data

seconds

Accessories – See page 15.71
Technical data – See page 15.76 - 82

1
0.5
0.1
0.05

DC

0.01
1

2

3

5

10

20 30

multiple of rated current

Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com

cir Min
cu ia
it b tur
S5 rea e
00 ke
r

Accessories
S500 UL1077

s

Auxiliary contacts

The auxiliary contacts will signal whether the breaker is in the ON or OFF position.
Description

For field mounting: left side

1 N.O./1 N.C.
2 N.O.

Catalog number

S500-H11
S500-H20

S500-H11, -H20

Bell alarm

The bell alarm includes a set of contacts that will only signal when the breaker has tripped.
Typically the contacts would be connected to an alarm or bell to signal the operator that an
overcurrent trip has occurred. The bell alarm also includes a test button for testing the alarm
contacts without opening the breaker.
Description

For field mounting: left side

1 N.O./1 N.C.
2 N.O.

Catalog number

S500-S11
S500-S20

S500-S11, -S20

Handle mechanism
Description

Handle mechanism

Catalog number

S500-RD3

For use with 1-4 pole S500 MCBs and disconnect switch selector handles with 5mm shafts.
S500-RD3

Power feed terminal - Accepts into 2/0 AWG
Description

Rear mount terminal

S500-K1

Catalog number

S500-K2

Rear mount terminal - Accepts into 2/0 AWG
Description

Accepts 4AWG/25mm

Catalog number

S500-K1

Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com

15

re s
tu ker
a
i
in ea
M it br 0
cu S50
cir

Technical data
S500-K & S500UC-B, K

Technical data
Approvals
UL
CSA
Number of poles
Tripping characteristic
Rated currents
Rated voltage
Frequency
Mounting position
Standard mounting
Clamps only for CU
Service life, mechanical at rated load
Ambient temperature

S500-K

S500UC-B, K

1077
C22.2 - No. 235
1, 2, 3
K
0.1 to 45 A
480Y/277 VAC, 600Y/346 VAC
50/60 Hz
vertical, horizontal
35mm DIN rail
16 - 4 AWG
20,000
40°C... 104°F

1077
C22.2 - No. 235
1, 2, 3, 4
B, K
B: 6 - 63 A; K: 0.15 - 45 A
250 VDC per pole (600 VDC 4 pole)
50/60 Hz
vertical, horizontal
35mm DIN rail
16 - 4 AWG
20,000
40°C... 104°F

Tripping characteristic K

10,000

5000

5000

1000
500

1000
500

100
50

100
50

10
5

10
5

1
0.5

1
0.5

seconds

10,000

seconds

15

Tripping characteristic B

AC
0.1
0.05

0.1
0.05

DC

DC

0.01

0.01
1

2

3

5

8 10 12

multiple of rated current

20 30

1

2

3

5

7 10

20 30

multiple of rated current

Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com

cir Min
cu ia
it b tur
S5 rea e
00 ke
r

Approximate dimensions
	S500 & Accessories

s

S500
2.95
75

1.97
50

0.98
25

3.64 92.5
1.73 44

3.15

3.62

1.77 45

80

92

CL

2.22

2.95 75

56.5

1.14
29

0.24 6
S500

S500-H11, S500-H20
S500-S11, S500-S20

S500-RD3 Handle mechanism

92
80
56.5

45
75
91

6

35

12.5

15

3.15 80

1.60 40.7

S500 handle mechanism

S500 Front mounting kit

CL

4.41

2.91

112

74

2.00
51

0.24 D

CUT-OUT

6D

CL

1.81
46

"L"
L + 0.51 13
L
L + 1.02 26

3.31 84

0.31 8

S500 FRONT MOUNT

Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com

Miniature circuit breakers

Technical data

Miniature circuit breakers
Technical data

	S201UP-K	

	

S201UP-K	

S201-B	

S201P-Z	

S201PR-K0.2	

cir Min
c
Te uit iatu
ch br re
nic ea
al ker
da s
ta

S201UDC-K1	

S501-K	S801U-B

S200

UL489
S200U-K................................................. 15.90
S200U-Z................................................. 15.90
S200UP-K............................................... 15.90
S200UP-Z............................................... 15.90
SU200PR-K............................................ 15.91
S200UDC-K............................................ 15.91
S200UDC-Z............................................ 15.91
UL1077
S200-B.................................................... 15.92
S200-C, D............................................... 15.92
S200-K.................................................... 15.92
S200-Z.................................................... 15.92
S200P-B................................................. 15.93
S200P-C................................................. 15.93
S200P-D................................................. 15.93
S200P-K................................................. 15.93
S200P-Z.................................................. 15.94
S200PR-K............................................... 15.94
S280UC-K............................................... 15.94
S280UC-Z............................................... 15.94

S800

UL489
S800U-K, Z............................................. 15.95
IEC
S800S-B................................................. 15.95
S800S-C................................................. 15.95
S800S-D................................................. 15.95
S800S-K................................................. 15.96

S500

UL1077
S500-K.................................................... 15.97
S500UC-B, K.......................................... 15.97

Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com

15

re s
tu ker
a
i
in ea ta
M it br l da
a
cu ic
cir echn
T

Item

Approvals:
UL
CSA
VDE
IEC
Number of Poles:
Tripping Characteristic:
Rated Currents:
Minimum Operating Voltage:
UL/CSA Rated Voltage
& Interrupting Capacity:
Frequency:
120VAC
240 VAC
277 VAC
277/480 VAC
60VDC
125VDC
250VDC
500VDC
IEC Rated Voltage
Frequency:
Rated Voltage
IEC Single Pole
IEC Multi-Pole
Production Category:
Depth of Unit Per DIN 43880:
Mounting Position:
Standard Mounting:
Main and Shunt Trip Terminals:
Wire Size
Torque
Tool
Accessory Terminals
Wire Size
Torque
Tool
Service Life at Rated Load:
Ambient Temperatures:
Minimum
Maximum
Storage Temperatures:
Minimum
Maximum
Shock Resistance:

15 Vibration Resistance:
Disconnecting Neutral Rating:

Technical data
S200U-K, S200U-Z, S200UP-K, S200UP-Z

S200U-K

S200U-Z

S200UP-K

S200UP-Z

489
C22.2 No. 5
0660
898, 60947-2
1,2,3,4
K
0.2 to 63A
12V

489
C22.2 No. 5
0660
898, 60947-2
1,2,3,4
Z
0.2 to 63A
12V

489
C22.2 No. 5
0660
898, 60947-2
1,2,3,4
K
0.2 to 25A
12V

489
C22.2 No. 5
0660
898
1,2,3,4
Z
0.2 to 25A
12V

50/60 Hz
10kA
10kA
—
—
15kA
15kA
—
—

50/60 Hz
10kA
10kA
—
—
15kA
15kA
—
—

50/60 Hz
10kA
10kA
10kA
10kA
15kA
15kA
—
—

50/60 Hz
10kA
10kA
10kA
10kA
15kA
15kA
—
—

50/60 Hz

50/60 Hz

50/60 Hz

50/60 Hz

240/415VAC, 220VDC
415VAC, 440VDC
IP20
68mm/ 2.68 in.
Vertical / horizontal
35mm DIN rail

240/415VAC, 60VDC
415VAC, 110VDC
IP20
68mm/ 2.68 in.
Vertical / horizontal
35mm DIN rail

240/415VAC, 220VDC
415VAC, 440VDC
IP20
68mm/ 2.68 in.
Vertical / horizontal
35mm DIN rail

240/415VAC, 220VDC
415VAC, 440VDC
IP20
68mm/ 2.68 in.
Vertical / horizontal
35mm DIN rail

18-4 AWG/.82-21.2mm²
17.5 in-lbs. / 1.978 Nm
# 2 Posidrive

18-4 AWG/.82-21.2mm²
17.5 in-lbs. / 1.978 Nm
# 2 Posidrive

18-4 AWG/.82-21.2mm²
17.5 in-lbs. / 1.978 Nm
# 2 Posidrive

18-4 AWG/.82-21.2mm²
17.5 in-lbs. / 1.978 Nm
# 2 Posidrive

18-16 AWG/.82-1.3mm²
4.5 in-lbs./.51nm
# 1 Posidrive
No Load 20,000 operations

18-16 AWG/.82-1.3mm²
4.5 in-lbs./.51nm
# 1 Posidrive
No Load 20,000 operations
Full Load 10,000 operations

18-16 AWG/.82-1.3mm²
4.5 in-lbs./.51nm
# 1 Posidrive
No Load 20,000 operations
Full Load 10,000 operations

18-16 AWG/.82-1.3mm²
4.5 in-lbs./.51nm
# 1 Posidrive
No Load 20,000 operations
Full Load 10,000 operations

-25ºC... -13ºF
70ºC... 158ºF

-25ºC... -13ºF
70ºC... 158ºF

-25ºC... -13ºF
70ºC... 158ºF

-25ºC... -13ºF
70ºC... 158ºF

-40ºC... -40ºF
70ºC... 158ºF
30g minimum of 2 impacts,
shock duration of 13ms
5g, 20 cycles, 5 Hz, 150 Hz

-40ºC... -40ºF
70ºC... 158ºF
30g minimum of 2 impacts,
shock duration of 13ms
5g, 20 cycles, 5 Hz, 150 Hz

—

—

-40ºC... -40ºF
70ºC... 158ºF
30g minimum of 2 impacts,
shock duration of 13ms
5g, 20 cycles, 5 Hz, 150 Hz
@ 0.8 ~ In
—

-40ºC... -40ºF
70ºC... 158ºF
30g minimum of 2 impacts,
shock duration of 13ms
5g, 20 cycles, 5 Hz, 150 Hz
@ 0.8 ~ In
—

Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com

Technical data
SU200PR-K, S200UDC-K, S200UDC-Z
Item

Approvals:
UL
CSA
VDE
IEC
Number of Poles:
Tripping Characteristic:
Rated Currents:
Minimum Operating Voltage:
UL/CSA Rated Voltage
& Interrupting Capacity:
Frequency:
120VAC
240 VAC
277 VAC
277/480 VAC
60VDC
125VDC
250VDC
500VDC
IEC Rated Voltage
Frequency:
Rated Voltage
IEC Single Pole
IEC Multi-Pole
Production Category:
Depth of Unit Per DIN 43880:
Mounting Position:
Standard Mounting:
Main and Shunt Trip Terminals:
Wire Size
Torque
Tool
Accessory Terminals
Wire Size
Torque
Tool
Service Life at Rated Load:
Ambient Temperatures:
Minimum
Maximum
Storage Temperatures:
Minimum
Maximum
Shock Resistance:
Vibration Resistance:
Disconnecting Neutral Rating:

SU200PR-K

S200UDC-K

S200UDC-Z

489
CS22.2 No. 5
0660
60947-2
1,2,3,4
K
0.2 to 63A
12 VAC

489
—
0660
—
1, 2
K
1 to 63A
—

489
—
0660
—
1, 2
Z
1 to 63A
—

50/60 Hz
10 kA
10 kA
10 kA
10 kA
—
—
—
—

50/60 Hz
—
—
—
—
14 kA
—
—
—

50/60 Hz
—
—
—
—
14 kA
—
—
—

50/60 Hz

50/60 Hz

50/60 Hz

240 VAC
400 VAC
IP20
68mm/ 2.68 in.
Any
35mm DIN rail

—
—
IP20
68mm/ 2.68 in.
Vertical / horizontal
35mm DIN rail

—
—
IP20
68mm/ 2.68 in.
Vertical / horizontal
35mm DIN rail

18-4 AWG/.82-21.2 mm²
25 in-lbs. / 2.8 Nm
# 2 Posidrive

18-4 AWG/.82-21.2 mm²
17.5 in-lbs. / 1.978 Nm
# 2 Posidrive

18-4 AWG/.82-21.2 mm²
17.5 in-lbs. / 1.978 Nm
# 2 Posidrive

18-16 AWG/.82-1.3mm2
4.5 in-lbs. / .51 Nm
# 1 Posidrive
6000 operations (AC),
1 cycle (1s-ON, 9s-OFF)

18-16 AWG/.82-1.3mm2
4.5 in-lbs. / .51 Nm
# 1 Posidrive

18-16 AWG/.82-1.3mm2
4.5 in-lbs. / .51 Nm
# 1 Posidrive

Full Load 10,000 operations

Full Load 10,000 operations

-25ºC... -13ºF
55ºC

-25ºC... -13ºF
70ºC... 158ºF

-25ºC... -13ºF
70ºC... 158ºF

-40ºC... -40ºF
70ºC... 158ºF
25g minimum of 2 impacts,
shock duration of 13 ms
5g, 20 cycles, 5-150, 5Hz
with load 0.8in
—

-40ºC... -40ºF
70ºC... 158ºF
30g minimum of 2 impacts,
shock duration of 13 ms
5g, 20 cycles, 5 Hz, 150 Hz

-40ºC... -40ºF
70ºC... 158ºF
30g minimum of 2 impacts,
shock duration of 13 ms
5g, 20 cycles, 5 Hz, 150 Hz

—

—

cir Min
c
Te uit iatu
ch br re
nic ea
al ker
da s
ta

Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com

15

re s
tu ker
a
i
in ea ta
M it br l da
a
cu ic
cir echn
T

15

Technical data
S200-B; S200-C, D; S200-K; S200-Z

Item
S200-B
Approvals:
UL
1077
CSA
C22.2 No. 235
VDE
0641, 0660
IEC
898, 60947-2
Number of Poles:
1,2,3,4, 1+N, 3+N
Tripping Characteristic:
B
Rated Currents:
6 to 63A
Minimum Operating Voltage:
12VAC
	 Single pole	 Multi pole
UL/CSA Rated Voltage
& Interrupting Capacity:
Frequency:
50/60 Hz
120VAC
	
10 kA	
—
240 VAC
	
6 kA	
10 kA
	
6 kA	
—
277 VAC
277/480 VAC
	
—	
6 kA
60VDC
	
10 kA	
10 kA
	
10 kA	
10 kA
125VDC
250VDC
	—	
—
500VDC
	—	
—
IEC Rated Voltage
Frequency:
50/60 Hz
Rated Voltage
IEC Single Pole
240/415 VAC, 60 VDC
IEC Multi-Pole
415 VAC, 110 VDC
Production Category:
IP20
Depth of Unit Per DIN 43880:
68mm/ 2.68 in.
Mounting Position:
Vertical / horizontal
Standard Mounting:
35mm DIN rail
Main and Shunt Trip Terminals:
Wire Size
18-4 AWG/.82-21.2 mm²
Torque
17.5 in-lbs. / 1.978 Nm
Tool
# 2 Posidrive
Accessory Terminals
Wire Size
18-16 AWG/.82-1.3 mm²
Torque
4.5 in-lbs./.51 Nm
Tool
# 1 Posidrive
Service Life at Rated Load:
No Load 20,000 operations
Full Load 10,000 operations
Ambient Temperatures:
Minimum
-25ºC... -13ºF
Maximum
70ºC... 158ºF
Storage Temperatures:
Minimum
-40ºC... -40ºF
Maximum
70ºC... 158ºF
Shock Resistance:
30g minimum of 2 impacts,
shock duration of 13 ms
Vibration Resistance:
5g, 20 cycles, 5 Hz, 150 Hz
Disconnecting Neutral Rating:
6 kA switching

S200-C, D

	

1077
C22.2 No. 235
0660
898, 60947-2
1,2,3, 1+N, 3+N
C, D
0.5 to 63A
12VAC
Single pole	 Multi pole

50/60 Hz
	
10 kA	
—
	
6 kA	
10 kA
	
6 kA	
—
	
—	
6 kA
	
10 kA	
10 kA
	
10 kA	
10 kA
	—	
—
	—	
—

S200-K

	

1077
C22.2 No. 235
0660
898, 60947-2
1,2,3,4, 1+N, 3+N
K
0.5 to 63A
12 V
Single pole	 Multi pole

50/60 Hz
	
10 kA	
—
	
6 kA	
10 kA
	
6 kA	
—
	
—	
6 kA
	
10 kA	
10 kA
	
10 kA	
10 kA
	—	
—
	—	
—

S200-Z

	

1077
C22.2 No. 235
0660
898, 60947-2
1,2,3,4, 1+N, 3+N
K
0.5 to 63A
12 V
Single pole	 Multi pole

50/60 Hz
	
10 kA	
—
	
6 kA	
10 kA
	
6 kA	
—
	
—	
6 kA
	
10 kA	
10 kA
	
10 kA	
10 kA
	—	
—
	—	
—

50/60 Hz

50/60 Hz

50/60 Hz

240/415 VAC, 60 VDC
415 VAC, 110 VDC
IP20
68mm/ 2.68 in.
Vertical / horizontal
35mm DIN rail

240/415 VAC, 60 VDC
415 VAC, 110 VDC
IP20
68mm/ 2.68 in.
Vertical / horizontal
35mm DIN rail

240/415 VAC, 60 VDC
415 VAC, 110 VDC
IP20
68mm/ 2.68 in.
Vertical / horizontal
35mm DIN rail

18-4 AWG/.82-21.2 mm²
17.5 in-lbs. / 1.978 Nm
# 2 Posidrive

18-4 AWG/.82-21.2 mm²
17.5 in-lbs. / 1.978 Nm
# 2 Posidrive

18-4 AWG/.82-21.2 mm²
17.5 in-lbs. / 1.978 Nm
# 2 Posidrive

18-16 AWG/.82-1.3 mm²
4.5 in-lbs./.51 Nm
# 1 Posidrive
No Load 20,000 operations
Full Load 10,000 operations

18-16 AWG/.82-1.3 mm²
4.5 in-lbs./.51 Nm
# 1 Posidrive
No Load 20,000 operations
Full Load 10,000 operations

18-16 AWG/.82-1.3 mm²
4.5 in-lbs./.51 Nm
# 1 Posidrive
No Load 20,000 operations
Full Load 10,000 operations

-25ºC... -13ºF
70ºC... 158ºF

-25ºC... -13ºF
70ºC... 158ºF

-25ºC... -13ºF
70ºC... 158ºF

-40ºC... -40ºF
70ºC... 158ºF
30g minimum of 2 impacts,
shock duration of 13 ms
5g, 20 cycles, 5 Hz, 150 Hz
6 kA switching

-40ºC... -40ºF
70ºC... 158ºF
30g minimum of 2 impacts,
shock duration of 13 ms
5g, 20 cycles, 5 Hz, 150 Hz
6 kA switching

-40ºC... -40ºF
70ºC... 158ºF
30g minimum of 2 impacts,
shock duration of 13 ms
5g, 20 cycles, 5 Hz, 150 Hz
6 kA switching

Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com

cir Min
c
Te uit iatu
ch br re
nic ea
al ker
da s
ta

Technical data
S200-P-B; S200P-C; S200P-D; S200P-K
Item
Approvals:
UL
CSA
VDE
IEC
Number of Poles:
Tripping Characteristic:
Rated Currents:
Minimum Operating Voltage:
UL/CSA Rated Voltage
& Interrupting Capacity:
Frequency:
120VAC
240 VAC
277 VAC
277/480 VAC
60VDC
125VDC
250VDC
500VDC
IEC Rated Voltage
Frequency:
Rated Voltage
IEC Single Pole
IEC Multi-Pole
Production Category:
Depth of Unit Per DIN 43880:
Mounting Position:
Standard Mounting:
Main and Shunt Trip Terminals:
Wire Size
Torque
Tool
Accessory Terminals
Wire Size
Torque
Tool
Service Life at Rated Load:
Ambient Temperatures:
Minimum
Maximum
Storage Temperatures:
Minimum
Maximum
Shock Resistance:
Vibration Resistance:
Disconnecting Neutral Rating:

S200P-B

	

1077
C22.2 No. 235
0660
898, 60947-2
1,2,3,4, 1+N, 3+N
K
0.5 to 63A
12 V
Single pole	 Multi pole

50/60 Hz
	
10 kA	
—
	
6 kA	
10 kA
	
6 kA	
—
	
—	
6 kA
	
10 kA	
10 kA
	
10 kA	
10 kA
	—	
—
	—	
—

S200P-C

	

1077
C22.2 No. 235
0660
898, 60947-2
1,2,3,4, 1+N, 3+N
K
0.5 to 63A
12 V
Single pole	 Multi pole

50/60 Hz
	
10 kA	
—
	
6 kA	
10 kA
	
6 kA	
—
	
—	
6 kA
	
10 kA	
10 kA
	
10 kA	
10 kA
	—	
—
	—	
—

S200P-D

	

1077
C22.2 No. 235
0660
898, 60947-2
1,2,3,4, 1+N, 3+N
K
0.5 to 63A
12 V
Single pole	 Multi pole

50/60 Hz
	
10 kA	
—
	
6 kA	
10 kA
	
6 kA	
—
	
—	
6 kA
	
10 kA	
10 kA
	
10 kA	
10 kA
	—	
—
	—	
—

S200P-K

	

1077
—
0660
898, 60947-2
1,2,3,4, 1+N, 3+N
K
0.2 to 63A
12 V
Single pole	 Multi pole

50/60 Hz
	
10 kA	
—
	
10 kA	
10 kA
	
10 kA	
—
	
—	
10 kA
	
15 kA	
15 kA
	
15 kA	
15 kA
	—	
—
	—	
—

50/60 Hz

50/60 Hz

50/60 Hz

50/60 Hz

240/415 VAC, 60 VDC
415 VAC, 110 VDC
IP20
68mm/ 2.68 in.
Vertical / horizontal
35mm DIN rail

240/415 VAC, 60 VDC
415 VAC, 110 VDC
IP20
68mm/ 2.68 in.
Vertical / horizontal
35mm DIN rail

240/415 VAC, 60 VDC
415 VAC, 110 VDC
IP20
68mm/ 2.68 in.
Vertical / horizontal
35mm DIN rail

240/415 VAC, 60 VDC
415 VAC, 110 VDC
IP20
68mm/ 2.68 in.
Vertical / horizontal
35mm DIN rail

18-4 AWG/.82-21.2 mm²
17.5 in-lbs. / 1.978 Nm
# 2 Posidrive

18-4 AWG/.82-21.2 mm²
17.5 in-lbs. / 1.978 Nm
# 2 Posidrive

18-4 AWG/.82-21.2 mm²
17.5 in-lbs. / 1.978 Nm
# 2 Posidrive

18-4 AWG/.82-21.2 mm²
17.5 in-lbs. / 1.978 Nm
# 2 Posidrive

18-16 AWG/.82-1.3 mm²
4.5 in-lbs./.51 Nm
# 1 Posidrive
No Load 20,000 operations
Full Load 10,000 operations

18-16 AWG/.82-1.3 mm²
4.5 in-lbs./.51 Nm
# 1 Posidrive
No Load 20,000 operations
Full Load 10,000 operations

18-16 AWG/.82-1.3 mm²
4.5 in-lbs./.51 Nm
# 1 Posidrive
No Load 20,000 operations
Full Load 10,000 operations

18-16 AWG/.82-1.3 mm²
4.5 in-lbs./.51 Nm
# 1 Posidrive
No Load 20,000 operations
Full Load 10,000 operations

-25ºC... -13ºF
70ºC... 158ºF

-25ºC... -13ºF
70ºC... 158ºF

-25ºC... -13ºF
70ºC... 158ºF

-25ºC... -13ºF
70ºC... 158ºF

-40ºC... -40ºF
70ºC... 158ºF
30g minimum of 2 impacts,
shock duration of 13 ms
5g, 20 cycles, 5 Hz, 150 Hz
6 kA switching

-40ºC... -40ºF
70ºC... 158ºF
30g minimum of 2 impacts,
shock duration of 13 ms
5g, 20 cycles, 5 Hz, 150 Hz
6 kA switching

-40ºC... -40ºF
70ºC... 158ºF
30g minimum of 2 impacts,
shock duration of 13 ms
5g, 20 cycles, 5 Hz, 150 Hz
6 kA switching

-40ºC... -40ºF
70ºC... 158ºF
30g minimum of 2 impacts,
shock duration of 13 ms
5g, 20 cycles, 5 Hz, 150 Hz
—

Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com

15

re s
tu ker
a
i
in ea ta
M it br l da
a
cu ic
cir echn
T

Technical data
S200P-Z; S200PR-K; S280UC-K; S280C-Z
S200P-Z

Item

Approvals:
UL
CSA
VDE
IEC
Number of Poles:
Tripping Characteristic:
Rated Currents:
Minimum Operating Voltage:
UL/CSA Rated Voltage
& Interrupting Capacity:
Frequency:
120VAC
240 VAC
277 VAC
277/480 VAC
60VDC
125VDC
250VDC
500VDC
IEC Rated Voltage
Frequency:
Rated Voltage
IEC Single Pole
IEC Multi-Pole
Production Category:
Depth of Unit Per DIN 43880:
Mounting Position:
Standard Mounting:
Main and Shunt Trip Terminals:
Wire Size
Torque
Tool
Accessory Terminals
Wire Size
Torque
Tool
Service Life at Rated Load:

15

Ambient Temperatures:
Minimum
Maximum
Storage Temperatures:
Minimum
Maximum
Shock Resistance:
Vibration Resistance:
Disconnecting Neutral Rating:

	

1077
—
0660
898, 60947-2
1,2,3,4
Z
0.5 to 63A
12 V
Single pole	 Multi pole

S280UC-K

S200PR-K
489
CS22.2 No. 5
0660
60947-2
1,2,3,4
K
0.2 to 63A
12 VAC

50/60 Hz
	
10 kA	
—
	
10 kA	
10 kA
	
10 kA	
—
	—	
—

50/60 Hz
10 kA
10 kA
10 kA
10 kA

	
15 kA	
15 kA
	
15 kA	
15 kA
	—	
—
	—	
—

—
—
—
—

	

1077
22.2, No. 235
0660
898, 60947-2
1,2,3
K
0.2 to 63A
12 V
Single pole	 Multi pole

50/60 Hz
	
10 kA	
10 kA
	
10 kA	
6 kA
	
10 kA	
6 kA
4.5 kA for 0.2-40 A
	—	
		
5 kA for 50-63 A
	
10 kA	
10 kA
	
10 kA	
—
	
4.5 kA	
4.5 kA
	
—	
4.5 kA

S280UC-Z

	

1077
22.2, No. 235
0660
898, 60947-2
1,2,3
Z
0.5 to 63A
12 V
Single pole	 Multi pole

50/60 Hz
	
10 kA	
—
	
10 kA	
10 kA
	
10 kA	
—
	—	
4.5 kA for 0.2-40 A
		
5 kA for 50-63 A
	
10 kA	
10 kA
	
10 kA	
10 kA
	
4.5 kA	
4.5 kA
	
—	
4.5 kA

50/60 Hz

50/60 Hz

50/60 Hz

50/60 Hz

240/415 VAC, 220 VDC
415 VAC, 440 VDC
IP20
68mm/ 2.68 in.
Vertical / horizontal
35mm DIN rail

240 VAC
400 VAC
IP20
68mm/ 2.68 in.
Any
35mm DIN rail

240/415VAC, 220VDC
415VAC, 440VDC
IP20
68mm/ 2.68 in.
Vertical / horizontal
35mm DIN rail

240/415VAC, 220VDC
415VAC, 440VDC
IP20
68mm/ 2.68 in.
Vertical / horizontal
35mm DIN rail

18-4 AWG/.82-21.2 mm²

18-4 AWG/.82-21.2 mm²

17.5 in-lbs. / 1.978 Nm
# 2 Posidrive

25 in-lbs. / 2.8 Nm
# 2 Posidrive

18-4 AWG/.82-21.2 mm² for
0.2 - 40A
18-2 AWG for 50 A & above
17.5 in-lbs. / 1.978 Nm
# 2 Posidrive

18-4 AWG/.82-21.2 mm² for
0.5 - 40A
18-2 AWG for 50 A & above
17.5 in-lbs. / 1.978 Nm
# 2 Posidrive

18-16 AWG/.82-1.3 mm²
4.5 in-lbs./.51 Nm
# 1 Posidrive
No Load 20,000 operations
Full Load 10,000 operations

18-16 AWG/.82-1.3 mm²
4.5 in-lbs./.51 Nm
# 1 Posidrive
6000 operations (AC),
1 cycle (1s-ON, 9s-OFF)

18-16 AWG/.82-1.3 mm²
4.5 in-lbs./.51 Nm
# 1 Posidrive
No Load 20,000 operations
Full Load 10,000 operations

18-16 AWG/.82-1.3 mm²
4.5 in-lbs./.51 Nm
# 1 Posidrive
No Load 20,000 operations
Full Load 10,000 operations

-25ºC... -13ºF
70ºC... 158ºF

-25ºC... -13ºF
55ºC

-25ºC... -13ºF
70ºC... 158ºF

-25ºC... -13ºF
70ºC... 158ºF

-40ºC... -40ºF
70ºC... 158ºF
30g minimum of 2 impacts,
shock duration of 13 ms
5g, 20 cycles, 5 Hz, 150 Hz

-40ºC... -40ºF
70ºC... 158ºF
25gminimum of 2 impacts,
shock duration of 13 ms
5g, 20 cycles, 5-150, 5Hz
with load 0.8in
—

-40ºC... -40ºF
70ºC... 158ºF
30g minimum of 2 impacts,
shock duration of 13 ms
5g, 20 cycles, 5 Hz, 150 Hz

-40ºC... -40ºF
70ºC... 158ºF
30g minimum of 2 impacts,
shock duration of 13 ms
5g, 20 cycles, 5 Hz, 150 Hz

—

—

—

Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com

Technical data
S800U-K, Z; S800S-B, S800S-C, S800S-D
Item

Approvals:
UL
CSA
VDE
IEC
Number of Poles:
Tripping Characteristic:
Rated Currents:
Minimum Operating Voltage:
UL/CSA Rated Voltage
& Interrupting Capacity:
Frequency:
120VAC
240 VAC
277 VAC
277/480 VAC
60VDC
125VDC
250VDC
500VDC
IEC Rated Voltage
Frequency:
Rated Voltage
IEC Single Pole
IEC Multi-Pole
Production Category:
Depth of Unit Per DIN 43880:
Mounting Position:
Standard Mounting:
Main and Shunt Trip Terminals:
Wire Size
Torque
Tool
Accessory Terminals
Wire Size
Torque
Tool
Service Life at Rated Load:
Ambient Temperatures:
Minimum
Maximum
Storage Temperatures:
Minimum
Maximum
Shock Resistance:
Vibration Resistance:
Disconnecting Neutral Rating:

cir Min
c
Te uit iatu
ch br re
nic ea
al ker
da s
ta

S800U-K, Z

S800S-B

S800S-C

S800S-D

489, E312425
22.2 No. 5.1
—
60947-2
1,2,3,4
K
10 to 100A
—

—
—
—
60947-2
1,2,3,4
B
10 to 125A
400/690VAC

—
—
—
60947-2
1,2,3,4
C
10 to 125A
400/690VAC

—
—
—
60947-2
1,2,3,4
D
10 to 125A
400/690VAC

50/60 Hz
—
50 kA multi, 30 kA single
—
—
—
—
—
—

50/60 Hz
—
50 kA multi, 30 kA single; IEC
—
—
—
—
—
—

50/60 Hz
—
50 kA multi, 30 kA single; IEC
—
—
—
—
—
—

50/60 Hz
—
50 kA multi, 30 kA single; IEC
—
—
—
—
—
—

—

50/60 Hz

50/60 Hz

50/60 Hz

—
—
IP20
—
Vertical / horizontal
35mm DIN rail

690 VAC
—
IP20
—
Vertical / horizontal
35mm DIN rail

690 VAC
—
IP20
—
Vertical / horizontal
35mm DIN rail

690 VAC
—
IP20
—
Vertical / horizontal
35mm DIN rail

1... 25
35 in-lbs. / 4 Nm
—

1... 25
35 in-lbs. / 4 Nm
—

1... 25
35 in-lbs. / 4 Nm
—

1... 25
35 in-lbs. / 4 Nm
—

1... 35
35 in-lbs./4 Nm
—
6,000 operations

1... 35
35 in-lbs./4 Nm
—
6,000 operations

1... 35
35 in-lbs./4 Nm
—
6,000 operations

1... 35
35 in-lbs./4 Nm
—
6,000 operations

-25ºC... -13ºF
60ºC... 140ºF

-25ºC... -13ºF
60ºC... 140ºF

-25ºC... -13ºF
60ºC... 140ºF

-25ºC... -13ºF
60ºC... 140ºF

-40ºC... -40ºF
70ºC... 158ºF
—
—
—

-40ºC... -40ºF
70ºC... 158ºF
—
—
—

-40ºC... -40ºF
70ºC... 158ºF
—
—
—

-40ºC... -40ºF
70ºC... 158ºF
—
—
—

Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com

15

re s
tu ker
a
i
in ea ta
M it br l da
a
cu ic
cir echn
T
Item
Approvals:
UL
CSA
VDE
IEC
Number of Poles:
Tripping Characteristic:
Rated Currents:
Minimum Operating Voltage:
UL/CSA Rated Voltage
& Interrupting Capacity:
Frequency:
120VAC
240 VAC
277 VAC
277/480 VAC
60VDC
125VDC
250VDC
500VDC
IEC Rated Voltage
Frequency:
Rated Voltage
IEC Single Pole
IEC Multi-Pole
Production Category:
Depth of Unit Per DIN 43880:
Mounting Position:
Standard Mounting:
Main and Shunt Trip Terminals:
Wire Size
Torque
Tool
Accessory Terminals
Wire Size
Torque
Tool
Service Life at Rated Load:
Ambient Temperatures:
Minimum
Maximum
Storage Temperatures:
Minimum
Maximum
Shock Resistance:
Vibration Resistance:
Disconnecting Neutral Rating:

Technical data
S800S-K
S800S-K
—
—
—
60947-2
1,2,3,4
K
10 to 125A
400/690 VAC
50/60 Hz
—
50 kA multi; 30 kA single; IEC
—
—
—
—
—
—
50/60 Hz
690 VAC
—
IP20
—
Vertical / horizontal
35mm DIN rail
1... 25
35 in-lbs. / 4 Nm
—
1... 35
35 in-lbs./4 Nm
—
6,000 operations
-25ºC... -13ºF
60ºC... 140ºF
-40ºC... -40ºF
70ºC... 158ºF
—
—
—

15

Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com

cir Min
c
Te uit iatu
ch br re
nic ea
al ker
da s
ta

Technical data
S500-K, Z; S500UC-B, K
	

Item	

S500-K, Z

Approvals:
	UL		
1077
	 CSA		
C22.2 - No. 235
	VDE		
0641/6.78­
	IEC		
—
1,2,3, +N, +NA
No. of poles:		
K
Tripping characteristic:		
Rated currents:		
0.1 to 45A
Rated voltage:
	 UL/CSA single pole		
277VAC
	 UL/CSA multi pole		
600YVAC
	 IEC single pole		
690VAC
Rated interrupting capacity:		
	 Single pole		
0.15-25A – 30KA/240VAC
			
14KA/277VAC
			
26-45A – 18KA/240VAC
			
14KA/277VAC
	 Multi-pole		
0.15-45A – 14KA/480VAC
			
6KA/600VAC
Frequency:		50/60Hz
Mounting position:		
Vertical / horizontal
Standard mounting:		
35mm DIN rail
Terminals:		
16-4AWG / 1-25mm2
Service life at rated load:		
20,000 operations
Calibration temperature:		
40°C

	

Item	

S500UC-B, K	

Approvals:
	UL			
	CSA		
	VDE		
No. of poles:	
Tripping characteristic:			
Rated currents:			

1077
C22.2
0660
1,2,3, 4
B, K
B: 6 to 63A
K: 0.15 to 45A

Rated voltage:
	 UL single pole		 			277VAC/250VDC
	 UL multi pole		 			600VAC/600VDC
			
690VAC/750VDC
	 IEC multi pole			
Rated interrupting capacity:			
	
B single pole:	
			 	
6 – 25A	
18KA/240VAC	 14KA/277VAC	
			 	
32 – 63A	 30KA/240VAC	 14KA/277VAC	
			 	
			 B two-pole:
6 – 63A	
14KA/480VAC	 6KA/600VAC	
			 	
				
B three-pole:
	
6 – 63A	
14KA/480VAC	 6KA/600VAC	
K single pole:	
	
0.15 – 25A	 30KA/240VAC	 14KA/277VAC	
	
32 – 45A	 18KA/240VAC	 14KA/277VAC	
	
K two-pole:
	
0.15 – 45A	 14KA/480VAC	 6KA/600VAC	
K three-pole:
	
0.5 – 45A	 14KA/480VAC	 6KA/600VAC	

30KA/250VDC
30KA/250VDC
30KA/500VDC
30KA/600VDC
30KA/250VDC
30KA/250VDC
30KA/500VDC
30KA/600VDC

Frequency:		 50/60Hz
Vertical / horizontal
Mounting position:			
35mm DIN-rail
Standard mounting:			
Terminals:
16-4AWG / 1-25mm2
			
			
Service life at rated load:		
20,000 operations

Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com

15



Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.6
Linearized                      : Yes
Author                          : ABB Low Voltage - Clearwater Tech
Create Date                     : 2013:05:09 09:11:20-06:00
Keywords                        : ABB, Miniature, Circuit, Breakers, Catalog, Distributors
Modify Date                     : 2013:05:10 13:19:54-06:00
Has XFA                         : No
XMP Toolkit                     : Adobe XMP Core 5.2-c001 63.139439, 2010/09/27-13:37:26
Metadata Date                   : 2013:05:10 13:19:54-06:00
Creator Tool                    : Adobe InDesign CS5 (7.0.4)
Format                          : application/pdf
Title                           : ABB Miniature Circuit Breakers Catalog
Description                     : ABB Miniature Circuit Breaker
Creator                         : ABB Low Voltage - Clearwater Tech
Subject                         : ABB Miniature Circuit Breakers Catalog Distributors
Document ID                     : uuid:b86170a2-e51b-466c-8348-37fa36ff8136
Instance ID                     : uuid:33d745f8-c184-4bcc-803b-f85472753aa7
Producer                        : Adobe PDF Library 9.9
Page Count                      : 96
EXIF Metadata provided by EXIF.tools

Navigation menu