Arkansas_3 2011_ 476547 Catalog 1
2014-07-05
: Pdf 476547-Catalog 1 476547-Catalog_1 784572 Batch5 unilog
Open the PDF directly: View PDF .
Page Count: 36
Download | |
Open PDF In Browser | View PDF |
Meter Mounting Equipment Arkansas, W. Tennessee, N. Mississippi Market MILBANK OVERVIEW MILBANK OVERVIEW 2 Charles A. Milbank 1879-1966 Bill Martin 1916-1998 Robert F. Waldrop 1922-2002 Robert F. Waldrop, II Chairman Katrina Waldrop Henke Vice Chairman Milbank: Quality Metering Products for 80+Years M ilbank Manufacturing Company was established in 1927 by Charles A. Milbank. Originally, the company manufactured high voltage switches; however, by 1941 Milbank devoted itself primarily to the manufacture of sheet metal enclosures and related equipment for the electrical generation and distribution industry. Today we are an industry leader in the manufacture of electrical meter sockets. Through a national network of manufacturer’s representatives we provide wholesale electrical distributors with quality electrical products for the utility, contractor, industrial and OEM markets. As the meter standards have changed, Milbank has been successful in adapting its product line to these changes. Our full scale engineering department designs products to meet customer specifications and satisfy all utility requirements. Milbank’s employee base of over 1,000 workers, along with our five manufacturing facilities comprising almost 550,000 square feet give us the flexibility to schedule, produce, and ship orders quickly. Currently, Milbank manufactures over 10,000 different catalog items, and this list continues to grow. Our unique product offering includes: Residential & Commercial Meter Sockets; Residential & Commercial Meter Pedestals; RV/MH Power Outlets, Service Pedestals, and Transformers; Commercial & Industrial Electrical Enclosures; Circuit Breakers; Disconnects & Safety Switches; Safety Sockets; Utility & Residential Secondary Pedestals; Hubs, and related accessories. If you don’t find a unit in this catalog to service your needs, send us your specifications and we will be happy to work with you. Our success has come from a loyal customer base that can rely on us to build quality products at 2 a fair price in a timely manner. Our willingness and ability to design and produce new products to meet our customer demands is an important factor to remain competitive in today’s electrical market. Milbank has been serving the electric utility & wholesale distribution industries for more than 80 years with innovative, quality engineered products. So remember us for all of your meter mounting and related requirements, and we will be happy to serve you as we have in the past–with dependable service and quality products! We take great pride in being one of the few family-owned businesses left in our industry. We are a third generation run business and truly believe that... FAMILY MAKES A DIFFERENCE! TABLE OF CONTENTS DISCONNECTS (30-200 AMP) 30 & 60 AMP FUSIBLE/NON-FUSIBLE AC DISCONNECTS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 AC DISCONNECT WITH GFCI PROTECTION / SPA BOX . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 SINGLE POSITION 125 & 200 AMP–4 TERMINAL–RINGLESS–600 VAC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 200 AMP–5 & 7 TERMINAL–HEAVY DUTY LEVER BYPASS–RINGLESS–600 VAC . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 320 AMP–4 & 5 TERMINAL–HEAVY DUTY LEVER BYPASS–RINGLESS–600 VAC . . . . . . . . . . . . . . . . . . . . . . . . . . . 9 320 AMP–7 TERMINAL–HEAVY DUTY LEVER BYPASS–RINGLESS–600 VAC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 METER MAINS 100 & 200 AMP–4 TERMINAL–RINGLESS METER MAIN . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11 200 AMP–4 TERMINAL–METER MAIN W/BREAKERS–RINGLESS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12 200 AMP–7 TERMINAL–METER MAIN–RINGLESS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13 320 AMP–4 TERMINAL–RINGLESS–METER MAIN WITH SIDE WIREWAY . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14 400 AMP–320 CONTINUOUS–METER MAIN COMBINATION W/LOAD CENTER . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15 MULTIPLE POSITION 100 & 200 AMP/POSITION–4 TERMINAL–HORIZONAL GANGS–RINGLESS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16 125 & 200 AMP/POSITION–4 TERMINAL–CONDOMINIUM METERING BANKS . . . . . . . . . . . . . . . . . . . . . . . . . . 17-18 CONDOMINIUM METERING BANKS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19-20 POWER OUTLETS & METERED PEDESTALS 100 AMP–4 TERMINAL–SERVICE POWER OUTLET . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21-22 200 AMP–METERED PEDESTALS–RINGLESS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23 MISCELLANEOUS CT ENCLOSURES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24 COMMERCIAL METER PEDESTALS OVERVIEW, APPLICATIONS & ACCESSORIES . . . . . . . . . . . . . . . . . . . . . 25-26 UQFP PLUG-IN SERIES CIRCUIT BREAKERS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27 ACCESSORIES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28-29 NEMA & UL RATINGS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30 CONDUIT & AMPACITY INFORMATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32 ENERGIZATION OF ELECTRICAL EQUIPMENT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33 MATERIALS AND FINISHES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34 ADDITIONAL MILBANK PRODUCTS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35 CATALOG INDEX . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31 3 TABLE OF CONTENTS CATALOG NUMBER LOGIC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 3 CATALOG NUMBER LOGIC CATALOG NUMBER LOGIC 4 4 30 & 60 AMP–FUSIBLE / NON-FUSIBLE–AIR CONDITIONER DISCONNECTS 30 & 60 AMP–FUSIBLE / NON-FUSIBLE–AIR CONDITIONER DISCONNECTS U3802 U3832 PROFILE Milbankʼs air conditioner disconnect has a removable hinged cover which makes wiring a breeze. Our compact design meets all wire bending space requirements in the NEC and, also, complies with article 440-14 in the NEC. To insure the safest conditions, we designed our disconnect pullers to be removable or they may be reinstalled in the off position. Another safety feature is the padlock provision on the front cover. As with all Milbank products, our enclosure is constructed of G90U galvanized steel and finished with an attractive, light gray, baked powder coating. Our state of the art finish combines epoxy and polyester hybrid resins into a hybrid powder coating which is then electrostatically applied. This offers a durable, nonfading finish. TECHNICAL INFORMATION AMP TYPE CATALOG NUMBER MAX WT. H.P. @ # 60 NON FUSIBLE U3802 10 3.25 60 NON AUTO U3812 10 3.3 30 FUSIBLE U3832 3 2.5 60 FUSIBLE U3860 10 3.3 LINE & LOAD WIRE RANGE CU AL #14-#2 AWG #14-#2 AWG #14-#3 AWG #14-#3 AWG #12-#2 AWG #12-#2 AWG #14-#3 AWG #14-#3 AWG GROUND WIRE RANGE DIMENSIONS WIRE RATING CU/AL D" W" CU °C #14-4 AWG 2-1/2 5 7-1/2 60°/75° 60°/75° #14-4 AWG 2-1/2 5 7-1/2 60°/75° 60°/75° #14-3 AWG 2-1/8 5 #14-3 AWG 3 5 H" 7 60°/75° AL °C 60° 9-1/4 60°/75° 60°/75° ✓ UL Listed as Enclosed Pullout Switch ✓ 1∅, 240 VAC ✓ Type 3R Rainproof ✓ One-inch concentric knockouts Utility requirements for this equipment may vary. Always consult the serving utility for their requirements before ordering or installing equipment in this catalog. 5 5 AC DISCONNECT / SPA BOX Combination AC Disconnect / 20 Amp GFCI Receptacle–Together in 1 Box AC DISCONNECT / SPA BOX 6 • Meets NEC #210.63 Requirements* • UL Listed as Power Outlet • Type 3R Enclosure • In-Use Cover** • Duplex Ground Connector • 1” Concentric Knockouts 60 amp, Non-Fused AC Disconnect Duplex 20 amp GFCI Receptacle WR-TR Type 3R Enclosure with In-Use Cover U3822-20GWR AMP 60 TYPE CATALOG MAX WT. NUMBER H.P. @ # NONFUSIBLE U3822-20GWR 10 AC DISCONNECT • 1∅, 240 Volt • 60 amp, Non-Fused GFCI RECEPTACLE • 20 amp • Reset/Test Button • Weather Resistant/Tamper Resistant • Meets NEC #406.8 Requirements* LINE & LOAD CONNECTOR GROUND CONNECTOR WIRE RANGE WIRE RANGE 6 CU AL CU/AL #14-#2 AWG #12-#2 AWG #14-4 AWG * NEC® #210.63 Heating, Air-Conditioning and Refrigeration Equipment Outlet. ...The receptacle shall be located on the same level and within 7.5 m (25 ft.) of the heating, air-conditioning and refrigeration equipment. * NEC® #210.68 GroundFault Circuit – Interruptor protection for personnel. * NEC® #406.8 receptacles in damp or wet locations. DIMENSIONS WIRE RATING D″ CU °C W″ H″ AL °C 4.8 5.25 7.4 60°/75° 60°/75° To ensure the safest conditions, Milbank disconnect pullers are designed to be reversible so they may be reinstalled in the OFF position. All units are designed with a padlock provision on the cover for security. **Note: U3822-20GWR cover rated as IN-USE COVER (Cover may be closed with cords plugged into receptacle). Units supplied with WRTR receptacle. *Reprinted with permission from NFPA 70-2002, National Electrical Code®, Copyright 2001, National Fire Protection Association, Quincy, MA 02269. This reprinted material is not the complete and official position of the NFPA on the referenced subject, which is represented only by the standard in its entirety. National Electrical Code® and NEC® are registered trademarks of the National Fire Protection Association, Quincy, MA. Hot Tub Disconnect or Sub Panel Breaker Enclosure–Type 3R Spa Box with GFCI Protection • • • • • • • • • • • 240 Volt ground fault protection UL listed, Type 3R rainproof Milbank reliability Easy installation 2 pole, 50 amp GFCI breaker protection Compact size: 8-1/2” H x 7-1/2” W x 3-3/4” D 3 or 4 wire installation 1∅, 120 / 240 VAC Standard package of 12 2 extra one-pole breaker spaces 100 amp overall rating Sub Panel Breaker Enclosure • Use as a 100 amp, 4 circuit sub pane enclosure • U4881-O has provision for (2) 2-pole or (4) 1-pole small frame breakers U4881-O-50GB AMP TYPE CATALOG NUMBER WT. @ # U4881-O LINE & LOAD CONNECTOR WIRE RANGE GROUND CONNECTOR WIRE RANGE DIMENSIONS CU AL CU/AL D″ W″ H″ 7 #14-1/0 #14-1/0 #14-1/0 3 3⁄4 71⁄2 81⁄2 50 BREAKER U4881-O-50GB 8 #14-1/0 #14-1/0 #14-1/0 3 3⁄4 71⁄2 81⁄2 60 BREAKER U4881-O-60GB 8 #14-1/0 #14-1/0 #14-1/0 3 3⁄4 71⁄2 81⁄2 – BREAKER PROVISION 6 125 & 200 AMP–4 TERMINAL–RINGLESS–600 VAC 2 3 4 55 125 & 200 AMP–4 TERMINAL–RINGLESS–600 VAC 1 8435 7040 7021 4 6 U8435-RL-TG U7040-RL-TG 1 2 2 1 6 3 5 4 4413 1980 3 4 5 6 U1980-O 125 & 200 AMP–4 TERMINAL–RINGLESS AMP SERVICE 125 OH/UG 200 OH 200 OH/UG 200 200 UG UG CATALOG NUMBER U8435-RL-TG U7021-RL-TG U7040-RL-TG U1980-O U4413-O CONNECTORS CU/AL HUB LINE H.O. #6-2/0 LOAD #6-2/0 H.O. #6-350 kcmil #6-350 kcmil H.O. #6-350 kcmil #6-350 kcmil BLANK BLANK #6-350 kcmil #6-350 kcmil #6-350 kcmil #6-350 kcmil BY- DIMENSIONS PASS D″ W″ H″ NONE NONE NONE NONE NONE 5 ⁄16 3 1 4 ⁄8 1 4 ⁄8 1 4 ⁄2 1 4 ⁄2 8 8 11 13 13 11 1 15 1 15 1 15 1 15 1 ⁄2 ⁄2 ⁄2 ⁄4 ⁄4 CONCENTRIC K.O.ʼS 1 2 1 1 1 ⁄2 1 2 ⁄2 1 2 ⁄2 1 2 ⁄2 1 2 ⁄2 1 ⁄2 1 2 ⁄2 1 2 ⁄2 1 2 ⁄2 1 2 ⁄2 3 2 1 2 ⁄2 1 2 ⁄2 3 1 2 ⁄2 4 1 1 ⁄4 – 5 – 1 ⁄4 6 1 ⁄4 1 1 4, 2 ⁄ ⁄ 1 1 1 4, 2 1 1 1 1 4, 2 1 1 1 4, 2 2 1 ⁄2 ⁄2 3 ⁄ ⁄ 2 1 ⁄2 ⁄2 HUBS: For proper hub selection see the hub suffix chart on the accessory page. FIFTH TERMINAL: For field mounted fifth terminal, order catalog number K5T to fit into square opening at the 9 oʼclock position of the new style block (#6-350 kcmil.) Order catalog number 5T8K2 to fit into round opening at the 9 oʼclock position of the old style block (#2-350 kcmil.) Order catalog number 5T8K2 for U8435. For the U7040 & U1980-O, order catalog number K5T. CONNECTORS: Extruded aluminum connectors are tin plated. Units are supplied with triplex neutral. Utility requirements for this equipment may vary. Always consult the serving utility for their requirements before ordering or installing equipment in this catalog. 7 7 1 ⁄4 ⁄ ⁄ ⁄ ⁄ 200 AMP–5 & 7 TERMINAL–HEAVY DUTY LEVER BYPASS–RINGLESS–600 VAC 200 AMP–5 & 7 TERMINAL–HEAVY DUTY LEVER BYPASS–RINGLESS–600 VAC 8 1 4 2 3 5 4 6 4581 4701 U4581-RL-QG U4701-RL-QG 2 1 4184 1 3 U4184-X 200 AMP–5 & 7 TERMINAL–RINGLESS–600 VAC CONNECTORS TERM SERVICE 5 7 7 OH/UG OH/UG OH/UG CATALOG NUMBER U4581-RL-QG U4184-X U4701-RL-QG CU/AL HUB LINE LOAD H.O. #6-350 kcmil #6-350 kcmil C.P. #6-350 kcmil #6-350 kcmil H.O. #6-350 kcmil #6-350 kcmil BY- DIMENSIONS PASS D″ W″ H″ LEVER LEVER LEVER 7 4 ⁄8 6 7 4 ⁄8 13 19 18 1 13 19 ⁄4 19 CONCENTRIC K.O.ʼS 1 2 3 1 2 ⁄2 4 4 3 1 2 ⁄2 3 4 5 3 3 1 1 1 4, 2 – – 3 1 ⁄ ⁄ 3 ⁄4 ⁄4 6 1 1 4, 2 ⁄ ⁄ – 1 1 4, 2 ⁄ ⁄ CONNECTORS: Extruded aluminum connectors are tin plated. The U4581 has a manual center disconnect on the neutral / center phase. LEVER BYPASS: Lever supplies clamping action and operates bypass device. BONDING LINK: U4581-RL-QG is factory bonded. Can be field isolated. Utility requirements for this equipment may vary. Always consult the serving utility for their requirements before ordering or installing equipment in this catalog. 8 320 AMP–4 & 5 TERMINAL–HEAVY DUTY LEVER BYPASS–RINGLESS–600 VAC 320 AMP–4 & 5 TERMINAL–HEAVY DUTY LEVER BYPASS–RINGLESS–600 VAC 320 AMP CONTINUOUS 400 AMP MAX 2 1 2 2 1 4 1 3 1 5161 3 4 4419 4505 4702 4 55 6 U4505-X U5161-X-K3L-K2L 1.13 10.75 7.30 16.31 30.00 8.44 2.88 1.00 10.00 1797 1.00 2.22 4.84 I.D. 15.00 O.D. 1 1/4” 1 3 4905 4 3” (5) 1/4”, 1/2” 2.19 .75 U1797-O-K3L-K2L 2 2 2.88 1.13 2.00 2.03 4.50 4.50 U4905-X 320 AMP–4 & 5 TERMINAL–RINGLESS CONNECTORS TERM SERVICE 4 OH/UG 4 OH/UG 4 UG 4 OH/UG CATALOG NUMBER U4702-X C.P. U5161-X-K3L-K2L C.P. U1797-O-K3L-K2L* C.P. U4905-X CU/AL HUB C.P. 5 OH/UG U4505-X C.P. 5 OH/UG U4419-X C.P. BY- DIMENSIONS PASS D″ W″ H″ LINE LOAD 3/8″-16 STUD (1) #4-600 or (2) 1/0-250 #4-600 or (2) 1/20-250 3/8″-16 STUD 3/8″-16 STUD 3/8″-16 STUD 3/8″-16 STUD LEVER 4 (2) #6-350 LEVER 4 TWIN #6-350 3/8″-16 STUD 3/8″-16 STUD 3/8″-16 STUD 7 ⁄8 7 ⁄8 7 LEVER 4 LEVER 5 ⁄8 3 ⁄4 7 LEVER 4 LEVER 4 ⁄8 7 ⁄8 15 15 15 16 15 15 CONCENTRIC K.O.ʼS 1 2 3 1 3 3 3 30 3 (1) 3 1 1 4, 2 28 ⁄4 30 3 38 3 4 28 1 3 29 3 ⁄4 ⁄4 ⁄ ⁄ 4 5 3 1 1 – 1 ⁄4 3 3 3 1 3 1 1 4, 2 3 ⁄2 ⁄4 ⁄ ⁄ ⁄4 – 3 3 3 1 1 3 3 1 2 ⁄2 ⁄4 ⁄4 HUBS: For proper hub selection see the hub suffix chart on the accessory page. LEVER BYPASS: Lever supplies clamping action and operates bypass device. CONNECTORS: Stud type units supplied with 3/8″-16 hex head nuts with Belleville washers. For single lug connector kits, order as extra K1539 (350 kcmil), K3082 (350 kcmil) or K3441 (600 kcmil). For twin lug connectors order as extra K1350 (350 kcmil) or K3442 (350 kcmil). Separate kits are required for both line and load. DISCONNECT: The U4419 has a manual center disconnect on the neutral / center phase. PHASES: The U4505 & U4419 are 1∅3W or 3∅3W, and the U4702 is 1∅3W. FIFTH TERMINAL: For field installed fifth terminal order catalog no. K3865. * SIDE WIREWAY Utility requirements for this equipment may vary. Always consult the serving utility for their requirements before ordering or installing equipment in this catalog. 9 9 6 1 1 4, 2 ⁄ ⁄ – 1 1 4, 2 ⁄ ⁄ – 1 1 4, 2 1 1 4, 2 ⁄ ⁄ ⁄ ⁄ 320 AMP–7 TERMINAL–HEAVY DUTY LEVER BYPASS–SIDE WIREWAY–RINGLESS–600 VAC 10 320 AMP–7 TERMINAL–HEAVY DUTY LEVER BYPASS–SIDE WIREWAY–RINGLESS–600 VAC 2 3 6 5 2120 4 2 2594 U2594-X 3 5 6 4 U2120-X 320 AMP–7 TERMINAL–SIDE WIREWAY–RINGLESS–3∅4W CONNECTORS SERVICE OH/UG UG CATALOG NUMBER U2594-X U2120-X CU/AL HUB C.P. C.P. LINE LOAD 3/8″-16 STUD 3/8″-16 STUD 3/8″-16 STUD 3/8″-16 STUD BY- DIMENSIONS PASS D″ W″ H″ LEVER LEVER 1 ⁄2 6 1 6 19 3 34 1 3 ⁄8 ⁄2 17 ⁄4 31 ⁄4 CONCENTRIC K.O.ʼS 1 – 4 2 3 3 3 – 4 4 5 4 1 3 2, 4, 1 4 6 1 ⁄ ⁄ 1 ⁄4 ⁄4 1 3 ⁄2, ⁄4,1 HUBS: For proper hub selection see the hub suffix chart on the accessory page. LEVER BYPASS: Lever supplies clamping action and operates bypass device. CONNECTORS: Stud type units supplied with 3/8″-16 hex head nuts with Belleville washers. For single lug connector kits, order as extra: K3082 (350 kcmil) or K3441 (600 kcmil). For twin lug connectors order as extra: K3442 (350 kcmil). Separate kits are required for both line and load. Utility requirements for this equipment may vary. Always consult the serving utility for their requirements before ordering or installing equipment in this catalog. 10 U5842/44 RINGLESS METER MAINS–240V U5844 Configuration U5842 RINGLESS METER MAIN MODELS CATALOG NUMBER AMP MAIN TERM SERVICE WT (#) U5842-RL-100 100 100a 4 OH 26 U5842-RL-200 200 200a 4 OH 26 U5844-PXL 200 2p* 4 OH/UG 37 U5844-PXL-100 100 100a 4 OH/UG 37 U5844-PXL-150 150 150a 4 OH/UG 37 U5844-PXL-200 200 200a 4 OH/UG 37 AIC RATING: All models are rated 22K AIC when Siemens breakers are used. HUB: OH/UG units supplied with one (1) closing plate packed inside. FIFTH TERMINAL: For field installed 208Y/120 network service order K5T. Installs in the 9 oʼclock position. *2 pole position. MAIN CIRCUIT BREAKER CHART Amperage 60 100 150 200 10KAIC Breaker Model Q260 Q2100 QN2150 QN2200 22KAIC Breaker Model Q260H Q2100H QN2150H QN2200H Utility requirements for this equipment may vary. Always consult the serving utility for their requirements before ordering or installing equipment in this catalog. 11 U5842/44 RINGLESS METER MAINS–240V U5842 Configuration 11 200 AMP–4 TERMINAL–RINGLESS–METER MAIN WITH BREAKERS–240V 200 AMP–4 TERMINAL–RINGLESS–METER MAIN WITH BREAKERS/BRKR. PROVISION–240V 12 1 3 5 6 1 4 2 5 5 6 5 6 5168 5268 U5168-XTL-200 U5268-XTL-200 1 K5815 – QN w/Q Interlock Kit (shown installed) for Standby Power Hookup 5898 2 6 3 4 5 U5898-O-200 200 AMP–4 TERMINAL–METER MAIN–22K AIC–120/240 VOLT–1Ø3W AVAIL. SERVICE CIRCUITS 8 20 8 OH/ UG OH/ UG UG CATALOG NUMBER U5168-XTL-200 U5268-XTL-200 U5898-O-200 CONNECTORS HUB LINE C.P. #6-350 kcmil C.P. #6-350 kcmil LOAD DIMENSIONS BYPASS D″ W″ H″ 1 #6-300 kcmil NONE 41⁄2 14 ⁄8 Breaker* Breaker C.P. #6-350 kcmil #6-350 kcmil NONE NONE 1 4 1 ⁄2 14 ⁄8 32 1 4 32 ⁄2 17 34 1 ⁄2 CONCENTRIC K.O.ʼS 1 2 2 2 2 2 3 4 3 1 1⁄ 3⁄ 1 3 2, 4, 1 2 , 4 1 1⁄ 3⁄ 1 3 2, 4, 1 2 , 4 1 1 2 3 3 1 2 ⁄2 2 2 ⁄2 ⁄2 5 6 ⁄ ⁄ ⁄ ⁄ 3 1 ⁄2 , ⁄4 ⁄4,1⁄2 HUB: Supplied with (2) closing plates packed inside. Order hubs as a separate item. See accessory page for hub options and twin hub openings. INTERIOR: U5168 and U5898 units have 8-circuit interior; U5268 units have 20-circuit interior. FIFTH TERMINAL: Order K5T and field install for 208Y/120 network systems. Installs in the 9 oʼclock position only for U5168 and U5268. In U5898, it can be rotated to 6 o'clock position.. BREAKERS: Rated 22K AIC with Milbank QNR2200H main installed. INTERLOCK KIT: For generator auxiliary circuit breaker interlock, order K5815 for large QN with small frame Q; order K5820 for large frame QN with large frame QN. *SUB-FEED LUGS: #6-350 kcmil sub-feed lugs provided on 8-circuit interior. Order K3701 for 20-circuit interior. Utility requirements for this equipment may vary. Always consult the serving utility for their requirements before ordering or installing equipment in this catalog. 12 200 AMP–7 TERMINAL–METER MAIN–RINGLESS–240V 2 1 1 3 5750 1 2 4 USE-22 4 3 U5750-RXL-200-BL USE-22-200-MB 200 AMP MAIN POWER OUTLET–BRANCH PROVISIONS–1∅3W–10K AIC RATING SERVICE OH OH CONNECTORS CATALOG NUMBER BREAKERS INSTALLED ADDITIONAL CIRCUITS * HUB USE-22-200-MB UQFB-M-200 4-Branch 2" USE-AP-200-MB UQFB-M-200 4-Branch 2" DIMENSIONS CONCENTRIC K.O.ʼS LINE D" W" H" 1 2 3 4 2/0-300 kcmil 4 81⁄8 225⁄8 1 2 1 3 2, 4 ⁄ ⁄ 1 3 2, 4 2 1 3 2, 4 1 3 2, 4 #4-250 5 8 26 1 ⁄ ⁄ ⁄ ⁄ ⁄ ⁄ NOTE: The neutral bus/ground bar is factory installed. USE-22-200-MB: 200 amp main with provisions for 200 AMP direct wire feeder. 200 amp bolt-on breaker wired in series with plug-in style bus. Space for four single pole or two 2-pole plug-in, branch circuit breakers. One 2″ hub included. Quadplex style breakers may be used in accordance with the NEC. 200 AMP–7 TERMINAL–METER MAIN–RINGLESS–3∅4W AMPS 200 CATALOG NUMBER HUB CONNECTOR CU/AL LINE U5750-RXL-200-BL C.P. #6-350 DIMENSIONS BYPASS LOAD D" W" H" C/B LEVER 5 3⁄4 17 3⁄8 34 CONCENTRIC K.O.ʼS 1 2 11⁄4-3 3-4 3 1 ⁄2-2 HUBS: For proper hub selection see the hub suffix chart on the accessory page. BYPASS: The lever supplies clamping action on the meter spade and also operates the bypass device. BREAKER: Factory installed 200 amp, 3-pole, 10,000 AIC Utility requirements for this equipment may vary. Always consult the serving utility for their requirements before ordering or installing equipment in this catalog. 13 200 AMP–7 TERMINAL–METER MAIN–RINGLESS–240V 1 13 320 AMP–4 TERMINAL–RINGLESS–METER MAIN WITH SIDE WIREWAY–240V 14 320 AMP–4 TERMINAL–RINGLESS–METER MAIN WITH SIDE WIREWAY–240V (U4031 AND U4835 PREWIRED WITH MILBANK LARGE FRAME BREAKERS) 1 3 4 5 1 2 2 4 4835 U4835-X-2/200-BL 5059 U5059-X-2/200-K3L 5894 U5894-X-2/200-MLK 320 AMP METER MAIN WITH BREAKERS–SIDE WIREWAY–1Ø3W–RINGLESS–120/240 VAC CONNECTORS SERVICE OH/UG CATALOG NUMBER CU/AL HUB U4835-X-2/200-BL C.P. OH/UG U5059-X-2/200-K3L C.P. LINE LOAD 3/8"-16 STUDS #4-600 KCMIL #1/0-300 KCMIL #1/0-300 KCMIL FIFTH BYDIMENSIONS TERM. PASS D″ W″ H″ KIT 3 K3866 LEVER 5 K3866 LEVER 4 ⁄4 7 ⁄8 CONCENTRIC K.O.ʼS 1 2 3 4 5 25 30 3 3 4 3 1 1 4, 2 15 42 3 3 3 1 1 1 4, 2 ⁄4 ⁄ ⁄ ⁄ ⁄ LEVER BYPASS: Lever supplies clamping action and operates bypass device. CONNECTORS: Sockets are supplied with 3/8” - 16 hex head nuts with Belleville washers. For connector lug kits, order as extra from chart on accessory page. Lug kit required for line side only. * BREAKERS: Supplied with (2) bolt-in Milbank UQFBH-200 breakers. Rated at 22K AIC. Supplied with (2) plug-in Milbank UQFPH-200 breakers. CONNECTORS SERVICE OH/UG OH/UG CATALOG NUMBER U5890-X-2/200 CU/AL HUB LINE C.P. U5892-X-2/200**¿ C.P. OH/UG U5894-X-2/200-MLK*¡ C.P. STUDS STUDS STUDS LOAD 1/0-300 1/0-300 1/0-300 FIFTH BYDIMENSIONS TERM. PASS D″ W″ H″ KIT K3865 K3865 K3865 LEVER LEVER LEVER 6 6 6 24 1 29 1 29 1 ⁄2 ⁄2 ⁄2 35 35 35 CONCENTRIC K.O.ʼS 1 2 3 4 5 4 1 1 –– –– 1 1 –– –– 1 1 –– –– 4 4 2 2 2 ⁄2 ⁄2 ⁄2 ⁄4 ⁄4 ⁄4 BREAKERS: U5890 installed with Milbank QN2200H breakers. U5894 and U5895 installed with left breaker QN2200H and right breaker QN2200RH. ¿ SUB-FEED LUGS: #6-350 kcmil sub-feed lugs provided on 8-circuit interior. Order K3701 for 20-circuit interior or –MLK for factory installed. ¡ SIDE WIREWAY *12-circuit load center **24-circuit load center Utility requirements for this equipment may vary. Always consult the serving utility for their requirements before ordering or installing equipment in this catalog. 14 400 AMP–320 AMP CONTINUOUS–METER MAIN COMBINATION WITH LOAD CENTER–240V 4 2 (9) 5 4(32) 3 2 M400-UG-APS-LC SPLIT MAIN W/ 24/40 CIRCUIT LOAD CENTER– 4 TERMINAL–1∅3W–TYPE 3R–RING TYPE–120/240 VAC SERV CATALOG NUMBER UG M400-UG-APS-LC ¿ DIMENSIONS PRIMARY SECONDARY BYDISCONNECT DISCONNECT PASS D" W" H" 200 Amp / 2 Pole 200 Amp / 2 Pole NONE 5 6 ⁄16 Circuit Breaker Circuit Breaker 29 41 7 ⁄16 CONCENTRIC K.O.ʼS 1 1 1 ⁄2 2 1 2 ⁄2 3 4 4 5 WT. # 3 1 110# ⁄4 UL LISTING: UL listed Service Entrance Equipment File E42827. NEUTRAL: Bonded neutral and ground factory Installed. LINE SIDE CONNECTORS: Two 1/2" studs per phase on 1 3/4" centers. SHORT CIRCUIT CURRENT WITHSTAND RATING: 10,000 AIC standard 22,000 AIC available. Consult factory. ¿ BREAKERS: Two 200 Amp 2-pole main breakers factory installed, and semi-flush flange kit packed inside meter section. Universal Copper 24 / 40 Circuit interior accepts Challenger, GE, Murrary, Siemens / ITE, and Cutler-Hammer / Westinghouse universal type plug-in branch circuit breakers. Utility requirements for this equipment may vary. Always consult the serving utility for their requirements before ordering or installing equipment in this catalog. 15 400 AMP–320 AMP CONTINUOUS–METER MAIN COMBINATION WITH LOAD CENTER–240V 1 15 100 & 200 AMP–4 TERMINAL–HORIZONTAL GANGS–RINGLESS–300V 16 100 & 200 AMP–4 TERMINAL–HORIZONTAL GANGS–RINGLESS–300V U1252-R 1 3 4 5 2 6 4 U8212-RL (4” side wireway / OH/UG service) 1 1 1 3 1252-3 3 1 4 2 2 6 5 3 1 4 3 4 1 1 1254-6 4 3 3 5 2 1 8212-6 5 100 & 200 AMP / POSITION–4 TERMINAL–RINGLESS–1∅3W–OH/UG* AMPS 100 100 100 100 100 200 200 200 NO. OF POS. 2 3 4 5 6 2 2 3 CATALOG NUMBER U8212-RL U8213-RL U8214-RL U8215-RL U8216-XL U4252-RXL-K2 U1252-REL-K1 U1253-X HUB LINE H.O. H.O. H.O. H.O. C.P. C.P. 21 ⁄2 C.P. 200 4 U1254-X C.P. 200 5 U1255-X C.P. 200 6 U1256-X CONNECTOR CU/AL C.P. #6-350 kcmil #6-350 kcmil #6-350 kcmil #6-350 kcmil #6-350 kcmil 3/8″-16 STUD 3/8″-16 STUD 3/8″-16 STUD 3/8″-16 STUD 3/8″-16 STUD 3/8″-16 STUD LOAD #6-2/0 #6-2/0 #6-2/0 #6-2/0 #6-2/0 #6-350 kcmil #6-350 kcmil #6-350 kcmil #6-350 kcmil #6-350 kcmil #6-350 kcmil BYPASS DIMENSIONS D″ W″ NONE 41⁄2 5 NONE 1 4 NONE 41 ⁄2 ⁄16 28 ⁄2 1 11 ⁄2 40 ⁄16 NONE 41⁄2 NONE 1 NONE 20 4 ⁄2 57 ⁄16 ⁄8 1 5 487⁄8 NONE 51⁄8 NONE 51 NONE 51 ⁄8 NONE 51⁄8 NONE 51 1 26 1 ⁄2 261⁄2 ⁄8 34 ⁄16 11 H″ 16 16 16 16 16 14 CONCENTRIC K.O.ʼS 1 2 2 2 2 2 21⁄2 14 21 14 21 ⁄2 ⁄2 2 3 4 5 2 21⁄2 2 21 ⁄2 1 1 21⁄2 1 1 2 21⁄2 1 1 2 21 1 1 21⁄2 1 1 3 21 1 1 1 3 2 4,1 3 21 ⁄2 1 1 1 1 4 2,1 1 1 1 4 2,1 2 2 2 2 2 3 2 ⁄2 ⁄2 ⁄2 ⁄2 ⁄2 1 6 1 ⁄4, ⁄2 ⁄4, ⁄2 ⁄4, ⁄2 ⁄4, ⁄2 ⁄4, ⁄2 ⁄4 ⁄4 ⁄4 – – – – – 1 ⁄,⁄ ⁄,⁄ 42 7 16 21⁄2 3 21⁄2 1 54 7 16 21⁄2 3 21⁄2 1 1 1 1 4 2,1 18 21 3 21 1 1 1 1 4 2,1 ⁄8 ⁄8 ⁄8 63 ⁄16 1 ⁄2 ⁄2 ⁄2 ⁄2 ⁄2 ⁄4 ⁄4 ⁄4 ⁄,⁄ ⁄,⁄ ⁄,⁄ HUB: For proper hub selection refer to the hub suffix chart on the accessory page. For the U1254-6 two hub openings are supplied and the extra opening is closed with a closing plate as standard. For the U8212 a hub opening is supplied at each end and the extra opening is closed with a closing plate as standard. FIFTH TERMINAL: For field mounted fifth terminal for U8212-6, order 5T8K2 (6 oʼclock position). For field mounted fifth terminal for U4252 & U1252-6, order catalog number K5T (9 oʼclock position). CONNECTORS: Extruded aluminum connectors are tin plated. BUSSING: Bussing is 5/16″ x 1″ aluminum on the U1252-1253, U4252 and the U8212-6. On the U1254-6 gangs the bussing is 3/8″ x 1″ aluminum. NOTE: See chart on page 32 for gang socket overall ampacities. Utility requirements for this equipment may vary. Always consult the serving utility for their requirements before ordering or installing equipment in this catalog. 16 U5882–86 & U5902–06 CONDOMINIUM METERING BANKS U5884-X CONDOMINIUM METERING BANKS 125A / POSITION CATALOG NUMBER AMP POSITIONS TERM SERVICE LINE LOAD WT (#) U5902-X 100 2 4 OH/UG 1/0-350 #6-350 58 U5903-X 100 3 4 OH/UG 1/0-350 #6-350 88 U5904-X 100 4 4 OH/UG 1/0-350 #6-350 107 U5905-X 100 5 4 OH/UG 1/0-350 #6-350 128 U5906-X 100 6 4 OH/UG 1/0-350 #6-350 146 OPTIONAL: 100 Amp are available with 100 Amp breakers from factory. 200A / POSITION CATALOG NUMBER AMP POSITIONS TERM SERVICE LINE LOAD WT (#) U5882-X 200 2 4 OH/UG 1/0-350 #6-350 58 U5883-X 200 3 4 OH/UG 1/0-350 #6-350 88 U5884-X 200 4 4 OH/UG 1/0-350 #6-350 107 U5885-X 200 5 4 OH/UG 1/0-350 #6-350 128 U5886-X 200 6 4 OH/UG 1/0-350 #6-350 146 OPTIONAL: 200 Amp are available with 200 Amp breakers from factory. AIC RATING: All models are rated 22K AIC. HUB: Units supplied with one (1) closing plate. Order hubs separately, see accesory page. FIFTH TERMINAL: For field installed 208Y/120 network service, order K5T. Installs in the 9 oʼclock position. CIRCUIT BREAKER CHART Manufacturer 10K Models 22K Models QP, QN QPH, QNH Cutler-Hammer BR, HPQ, QPGF — Square D G.E. (50 Amp Max.) Homeline THQL, THQL-GF — — Siemens Utility requirements for this equipment may vary. Always consult the serving utility for their requirements before ordering or installing equipment in this catalog. 17 U5882–86 & U5902–06 CONDOMINIUM METERING BANKS U5882-X 17 CONDOMINIUM METERING BANKS DIMENSIONAL INFORMATION CONDOMINIUM METERING BANKS DIMENSIONAL INFORMATION 18 CONDOMINIUM BANKS CondominiumMETERING Metering Banks Dimensional Information Dimensional Information KNOCKOUTS 1 3 2 3 2 1⁄ 2 1 4 5 ⁄8 1 7 ⁄4 30" 30" 30" 30" 2 2 26.5" 26.5" 2 4 5 1 3 4 5882 5882 5902 5902 2 5.125" 5.125" 34.56" 34.56" 5.125" 5.125" 2 30" 30" 2 1 3 1 5883 5883 5903 5903 2 30" 30" 5.125" 5.125" 42.81" 42.81" 2 2 1 3 1 2 5884 5884 5904 5904 2 5.125" 5.125" 51.06" 51.06" 2 2 2 1 3 1 2 30" 30" 5.125" 5.125" 59.31" 59.31" 2 2 2 1 3 1 2 18 2 2 5886 5886 5906 5906 2 5885 5885 5905 5905 CONDOMINIUM METERING BANKS–240V 19 CONDOMINIUM METERING BANKS–240V U2854-X (Order circuit breakers as extra) U2866-X VERTICAL 125 AMP/POSITION 200 AMP/POSITION NO. OF POS. CATALOG NUMBER MAIN BUS RATING LINE CONNECTOR SIZE NO. OF POS. CATALOG NUMBER MAIN BUS RATING LINE CONNECTOR SIZE 2 U2852-X 200 AMP *3/8″-16 STUD 2 U2862-X 250 AMP *3/8″-16 STUD 3 U2853-X 200 AMP *3/8″-16 STUD 3 U2863-X 300 AMP *3/8″-16 STUD RECTANGULAR 125 AMP/POSITION 200 AMP/POSITION NO. OF POS. CATALOG NUMBER MAIN BUS RATING LINE CONNECTOR SIZE NO. OF POS. CATALOG NUMBER MAIN BUS RATING LINE CONNECTOR SIZE 4 U2854-X 400 AMP *3/8″-16 STUD 4 U2864-X 400 AMP *3/8″-16 STUD 5 U2855-X ① 400 AMP *3/8″-16 STUD 5 U2865-X 600 AMP *3/8″-16 STUD 6 U2856-X ① 400 AMP *3/8″-16 STUD 6 U2866-X 600 AMP *3/8″-16 STUD *CONNECTORS: For line wire connector kits, order separately. FIFTH TERMINALS: For field mounted fifth terminal order catalog number K2381. Order one per meter position (9 oʼclock position only). BREAKERS: Units have provision for one double pole main per meter position. Breakers not included. Order as extra Milbank. CONNECTOR KITS * SIZE SUFFIX KIT COMPATIBLE NUMBER WITH -K1 K1539 -K3 K1540 SINGLE -K2 K1350 TWIN -K4 K1541 U2852-56 U2862-66 U2854-56 U2864-66 U2854-56 U2863-66 U2864-66 WIRE RANGE ① NOT STOCKED #6-350 kcmil PLUG-IN BREAKER COMPATIBILITY CHART #4-600 kcmil AMPS #6-350 kcmil 125-200 HQP / BR / WBJ #2-600 kcmil ≤ 100 SIEMENS MURRAY / CROUSE-HINDS G.E. SQ-D – MD Q LINE – QP MP Q LINE HOMELINE CUTLER-HAMMER SIEMENS (WESTINGHOUSE) (ITE) QP / BR / HQP Utility requirements for this equipment may vary. Always consult the serving utility for their requirements before ordering or installing equipment in this catalog. 19 CONDOMINIUM METERING BANKS–240V CONDOMINIUM METERING BANKS–240V 20 VERTICAL 125 &200 amp/pos. (single position) 125 amp/pos. (2-3 position) D 200 amp/pos. (2-3 position) D D 21" A C B A 25" or 37" C 13" or 18" 29" or 41" 5 13/16" 5 13/16" E E E B C 18" E E E U2852-X B C 5 13/16" 21" CONDOMINIUM METERING BANKS RECTANGULAR 125 amp/pos. (4, 5 & 6 position) 200 amp/pos. (4, 5 & 6 position) D FIG. DIMENSIONS A 11⁄4 ″ CONCENTRIC K.O. B 1 D 37" or 25" 29" or 41" ⁄4,1⁄2″ CONCENTRIC K.O. C 3″ CONCENTRIC K.O. D 4″ HUB OPENING E 2″ CONCENTRIC K.O. A A A C B 31" A A A 4 7/8" E E E B C 36" 20 E E E 4 7/8" 100 AMP–4 TERMINAL–SERVICE POWER OUTLET–240V 100 AMP–4 TERMINAL–SERVICE POWER OUTLET–240V TEMP POWER 25 15/16 MILBANK 5 3/8 CL MILBANK 3 5/16 9” 5 1/4 U4908-O-11GR 1 5/8 4908 3 4 3 4 5100 U5100-XL-75 Loop feed not available. SPECIFICATIONS ● Available in ringless style (U4908 series) or ring type (U4909 series). ● UL Listed 100 Amp, 120/240 Volt – 1∅ Underground Service Power Outlet. (U4908-UG and U5101-OH) ● Type 3R welded enclosure for durable outdoor use. ● Hub opening with closure plate. (U5101) ● Wire terminations accept copper or aluminum conductors. (U4908) Service–Line & Neutral: (1) #6-2/0 Load Ground: (2) 1/0-#14 & (4) #6-#14 Load Neutral: (2) 1/0-#14 & (4) #6-#14 ● ● Service Ground: #2-#8 Wire terminations accept copper or aluminum conductors. Loop feed not available. (U5101) Line: (1) #6-250 kcmil Ground: (2) 1/0-#14 & (4) #6-#14 Neutral: (2) 1/0-#14 & (4) #6-#14 Four terminal, ringless meter socket with stainless steel locking hasp. Utility requirements for this equipment may vary. Always consult the serving utility for their requirements before ordering or installing equipment in this catalog. 21 21 SERIES U4908 & U4909 STANDARD CONFIGURATIONS SERIES U4908 & U4909 STANDARD CONFIGURATIONS 22 U5100 & U5101 STANDARD CONFIGURATIONS ORDERING INFORMATION CATALOG # SOCKET TYPE DESCRIPTION U4908-O-(*) Ringless (*) Add suffix from above chart to complete catalog number (ie: U4908-O-11GR) U5101-XL-(*) Ringless (*) Add suffix from above chart to complete catalog number (ie: U5101-XL-11GR) * Cover may not close completely while in use with Twist-Locking devices. Available without meter and available as ring type. Other configurations available, consult factory. Utility requirements for this equipment may vary. Always consult the serving utility for their requirements before ordering or installing equipment in this catalog. 22 U5136 & U5137–RINGLESS–METERED PEDESTALS 23 U5136 & U5137–RINGLESS–METERED PEDESTALS U5136-0-200S-10GR with series wired main SPECIFICATIONS • 200 amp maximum, 120/240 volt, single phase, three wire meter socket • Ringless meter socket with horn bypass and stainless steel latch • Short circuit withstand rating 22K AIC. • Wire terminations accept copper or aluminum conductors • Line & Neutral: (2) #6-350 kcmil per phase • Line Ground: (4) #14-1/0 • Load (CB): 2/0 to 300 kcmil per pole • Load Neutral: (1) #6-350 kcmil • Load Ground: (2) #14-1/0, (4) #14/6 • Milbank plug-in main circuit breaker. Available in 100, 125, 150 & 200 amp. Type UQFPH-M. • Four-circuit plated copper interior accepts (2) 2-pole or (4) 1-pole standard plug-in type circuit breakers up to a total of 125 amps maximum. Acceptable manufacturers: Cutler-Hammer, GE or Siemens • Factory installed receptacle bridge and receptacle / circuit breakers. SINGLE PEDESTAL (DIRECT BURIAL) CATALOG NUMBER MAIN BREAKER MAIN CB BRANCH WT (#) U5136-0-100S UQFPH-M-100 100 4 Circuit 82 U5136-0-200S UQFPH-M-200 200 4 Circuit 82 U5136-0 (parallel wired) provision for UQFPH-M Series ––– 4 Circuit 80 DOUBLE PEDESTAL (DIRECT BURIAL) CATALOG NUMBER MAIN BREAKER MAIN CB BRANCH WT (#) U5137-0-100S (2) UQFPH-M-100 100 4 Circuit 115 U5137-0-200S (2) UQFPH-M-200 200 4 Circuit 115 U5137-0 (parallel wired) provision for (2) UQFPH-M Series ––– 4 Circuit 111 K5415 Stabilizer Foot sold separately. Pad mount pedestals require K5035 pad mount kit. Order separately. Pad mount available. Utility requirements for this equipment may vary. Always consult the serving utility for their requirements before ordering or installing equipment in this catalog. 23 CT ENCLOSURES CT ENCLOSURES 24 403214-TC3R-SP1 307220-TC3R-WB OUTDOOR TRANSFORMER CABINETS–NEMA 3R DIMENSIONS CATALOG NUMBER D″ W″ H″ 403214-TC3R-SP1 14 40 32 543214-TC3R-SP1 14 54 32 307220-TC3R-WB* 20 30 72 363616-CT3R-WB* 16 36 36 *Wood backboard factory installed. Bottom panel kit available for 307220-TC3R-WB, order A-3020-BTMKIT. 24 COMMERCIAL METER PEDESTALS OVERVIEW • Attractive Un-Strut Your Stuff... • Easy to install • Secure • Cost effective ilbank Commercial Pedestals are pad-mounted, weatherproof electrical enclosures consisting of a utility pull section with optional meter socket, and a customer section containing distribution and control equipment. Milbank Commercial Pedestals are an attractive, secure, easy to install and costeffective solution when underground remote site power distribution and control equipment is required, replacing unsightly and inefficient strut and backboard structures. Strut and backboard design Commercial Pedestal UL Listed as Industrial Control Equipment (File E113855). STANDARD FEATURES –COMMERCIAL PEDESTALS Ringless Socket Ring-type Socket Utility Lug Landing Customer Interior • Type 3R rainproof, vandal-resistant cabinet of polyurethane powder-coated steel (aluminum or stainless steel also available) • UL listed as enclosed industrial control equipment (UL508) • Isolated, lockable & sealable utility metering & lug landing sections • Lockable customer section for distribution & control equipment with internal deadfront • Print pocket inside customer section door contains wiring schematics and installation instructions • Most load centers are UL listed for use with various manufacturers’ circuit breakers • All stainless steel external hardware (screws, bolts, hinges, handles, hasps and sealing screws) • Meets EUSERC 308 and other utility standards. 25 COMMERCIAL METER PEDESTALS OVERVIEW Commercial Pedestals 25 APPLICATIONS & ACCESSORIES 26 APPLICATIONS & ACCESSORIES APPLICATIONS These units are ideal for controlling and metering: • Traffic signals • Street lighting • Irrigation / sprinkler systems • Cell towers / telephone vaults • Pump stations • Temporary power for fairgrounds, swap meets, outdoor markets, portable offices, holiday lights, etc. • Outdoor lighting for athletic fields, tennis and basketball courts, parking lots, landscaping and subdivision entrances, etc. AVAILABLE FACTORY-INSTALLED OPTIONS • Meter sockets – ring type or ringless, to 400 amp (unmetered and dual-metered pedestals also available) • Main and branch breakers or T fuses • Distribution – copper load centers & panel boards • Clocks / timers / relays • Photoelectric cells and controls • Power receptacles – pin & sleeve, twist lock or straight blade • Contactors – definite purpose, electrical or mechanically held, IEC and mercury types • Surge protection & lightning arrestors • Reserve inlet generator receptacle with interlocked circuit breakers • Motor starters, relays • Push button controls • Thermostat controls, fans and heating strips • Power blocks and terminal blocks • Steel, aluminum and plywood back boards • Transformers • Interlock devices for circuit breakers • Available in steel, aluminum (raw painted or anodized) or stainless steel construction with powder-coated finish available in 8 standard colors or special ordered RAL colors. • Available for applications up to 400 amp, 120V, 208V, 240V, 277V, 480V – 1Ø or 3Ø. ACCESSORIES 105J Fifth terminal kit for use with ring-type meter sockets CP-TC7D 7-day time clock kit CP-TC24H 24-hour time clock kit CP-TCWIRE Male four-pin connector and wiring harness for use with time clocks other than shown K3865 Fifth terminal kit for use with ringless meter sockets CP-16FPAD Fiberglass pedestal mounting base for 16" pedestal (direct buried) CP-ABK5/8 Anchor bolt kit (includes four 5/8 13 x 18" anchor bolts) CP-16PDMNT-CALT Pedestal mounting base for 16" pedestal CP-24PDMNT-CALT Pedestal mounting base for 24" pedestal (includes mounting hardware) CP-32PDMNT Pedestal mounting base for 32" pedestal (includes mounting hardware) 26 CP-PE-HOA-3POS HOA switch – for field installation UQFP PLUG-IN SERIES CIRCUIT BREAKERS 27 UQFP PLUG-IN SERIES CIRCUIT BREAKERS UQFP UQFP-M 200 AMP FRAME—PLUG-IN—10,000 AIC & 22,000 AIC TWO-POLE—COMMON TRIP 10K AIC PLUG-IN 22K AIC PLUG-IN 100 UQFP-100 UQFPH-100 125 UQFP-125 150 AMPS 10K AIC PLUG-IN 22K AIC PLUG-IN WIRE RANGE CU AL UQFP-M-100 UQFPH-M-100 #3-#1 #1-1/0 UQFPH-125 UQFP-M-125 UQFPH-M-125 #3-#1 #1-1/0 UQFP-150 UQFPH-150 UQFP-M-150 UQFPH-M-150 1/0-300 2/0-300 175 UQFP-175 UQFPH-175 UQFP-M-175 UQFPH-M-175 1/0-300 2/0-300 200 UQFP-200 UQFPH-200 UQFP-M-200 UQFPH-M-200 1/0-300 2/0-300 UL LISTED: For use with 60°C or 75°C wire. UQFP: For parallel main circuit breaker applications UQFP-M: For series main circuit breaker applications. Split load tab features allow for feed through capability. STANDARD PACKAGING: 5 units per 16 lb. carton. Utility requirements for this equipment may vary. Always consult the serving utility for their requirements before ordering or installing equipment in this catalog. 27 ACCESSORIES ACCESSORIES 28 INTERCHANGEABLE UNIT HUBS SMALL “RL" OPENING (STANDARD) SUFFIX LARGE “R” OPENING (HEAVY DUTY) SUFFIX SIZE MILBANK NO. F G H 3″ 31⁄2″ 4″ A8110 A8111 A8112 SIZE MILBANK NO. 1″ A7514 A7515 A7516 A7517 A7518 WL YL ZL DL EL 11⁄4″ 11⁄2″ 2″ 21⁄2″ ANTI-INVERSION CLIP K4802 BYPASS LINK K8180 (Bypass links sold in pairs) REMOVABLE HUB CLOSING PLATE HUB ADAPTER PLATE (Converts 4″ opening to 21⁄2″) S8324 DESCRIPTION SUFFIX CAT. # STANDARD (for -RL opening) -XL A7551 LARGE (for -R opening) -X A9064 ISOLATED NEUTRAL KIT K1047 CONNECTOR KITS TAP CONNECTORS (3 per set) For use with 3/8”-16 stud type units only SINGLE TWIN SUFFIX K1 K3 K3L CATALOG # (3 per set) – 1 ∅ 6-350 kcmil 4-600 kcmil or K1540 (2) 1/0-250 kcmil 4-600 kcmil or K1540L (2) 1/0-250 kcmil Non-rotating K1539 SUFFIX CATALOG # (4 per set) – 3 ∅ K5 K3082 6-350 kcmil 4-600 kcmil or (2) 1/0-250 kcmil K7 K3441 SUFFIX CATALOG # K2 K1350 K2L K1350L K4 K1541 SUFFIX CATALOG # K6 K8 K3442 K3083 (3 per set) – 1 ∅ 6-350 kcmil 6-350 kcmil Non-rotating 4-600 kcmil (4 per set) – 3 ∅ 6-350 kcmil 4-600 kcmil 28 Replaces the line or load side slide-in nut assembly on Milbank 200 amp sockets. Allows for a 100 amp tap location in addition to the #6-350 kcmil load-side connector. K5022 Includes Safety Barrier Extensions– for applications over 300 VAC. K4977-INT INTERNAL HEX K5022-INT INTERNAL HEX ACCESSORIES DISCONNECT SLEEVE * M5-144 (*NOT TO BE USED WITH LEVER BYPASS SOCKETS) HEAVY DUTY JAW CLAMPING K3865 (K3866 w/out neutral wire) 100-200 amp “PLUG-IN” FIFTH TERMINAL 5T8K2 TRIPLEX GROUND 200 amp FIFTH TERMINAL K5T (New style block with square hole) FOR CONDO METERING BANKS (125-200 amp) K2381 K1190 (For factory installed triplex ground add suffix “-TG” to the catalog number.) CLOSING COVERS SEALING RINGS METER CLOSING PLATE (Ring type / Ringless) 6003 (Gray Plastic) 6116 (Clear Plastic) METAL CLOSING PLATE (For Ringless sockets) CP-21 (For Ring type sockets) MCP SNAP ACTION MR-2 SCREW TYPE (Stainless Steel) MR-4 29 ACCESSORIES FIFTH TERMINALS 29 NEMA & UL RATINGS NEMA and UL are standard writing organizations commonly recognized in the North American continent. The following ratings are based on similar application descriptions and expected performance. UL requires enclosure testing by qualified evaluators. The Milbank Test Lab is certified in the UL Client Test Data Program. They also send site inspectors to check manufacturer adherence to prescribed manufacturing methods and material specifications. NEMA does not require independent testing, which leaves compliance totally up to the manufacturer. RATING NEMA TYPE 1 National Electrical Manufacturers Association (NEMA Standard 250) Enclosures are intended for indoor use primarily to provide a degree of protection against limited amounts of falling dirt. Underwriters Laboratories Inc. (UL 50 and UL 508) Canadian Standards* CAN/CSA–C22.2 No. 94-M91 Indoor use primarily to provide a degree of protection against limited amounts of falling dirt. General purpose enclosure. Protects against accidental contact with live parts. Outdoor use primarily to provide a degree of protection against rain, sleet, windblown dust, and damage from external ice formation. An Enclosure for either indoor or outdoor use, constructed so as to provide a degree of protection against rain, snow, and windblown dust; undamaged by the external formation of ice on the enclosure. Outdoor use primarily to provide a degree of protection against rain, sleet, and damage from external ice formation. An Enclosure for either indoor or outdoor use, constructed so as to provide a degree of protection against rain, snow, and windblown dust, splashing and hosedirected water; undamaged by the external formation of ice on the enclosure. Indoor or outdoor use primarily to provide a degree of protection against windblown dust and rain, splashing water, hose-directed water, and damage from external ice formation. An Enclosure for either indoor or outdoor use, constructed so as to provide a degree of protection against rain, snow, and windblown dust, splashing and hosedirected water; undamaged by the external formation of ice on the enclosure. Enclosures are intended for indoor and outdoor use primarily to provide a degree of protection against corrosion, windblown dust and rain, splashing water, hose-directed water, and damage from external ice formation. (NEMA Standard 1-10-1979) Indoor or outdoor use primarily to provide a degree of protection against corrosion, windblown dust and rain, splashing water, hose-directed water, and damage from external ice formation. An Enclosure for either indoor or outdoor use, constructed so as to provide a degree of protection against rain, snow, and windblown dust, splashing and hosedirected water; undamaged by the external formation of ice on the enclosure; resists corrosion. Enclosures are intended for indoor use primarily to provide a degree of protection against circulating dust, falling dirt, and dripping noncorrosive liquids. Indoor use primarily to provide a degree of protection against circulating dust, falling dirt, and dripping noncorrosive liquids. An Enclosure for either indoor use, constructed so as to provide a degree of protection against circulating dust, lint, fibers, and flyings; dripping and light splashing of noncorrosive liquids; not provided with knockouts. Enclosures are intended for indoor use primarily to provide a degree of protection against dust, spraying of water, oil, and noncorrosive coolant. Indoor use primarily to provide a degree of protection against lint, dust, seepage, external condensation, and spraying of water, oil, and noncorrosive liquids. Indoor use; provides a degree of protection against circulating dust, lint, fibers, and flyings; seepage and spraying of noncorrosive liquids, including oils and coolants. The definitions on this page are reproduced with permission from NEMA. These descriptions are not intended to be complete representations of National Electrical Manufacturers Association standards. The preceding definitions were reproduced with permission from Underwriters Laboratories Inc. Enclosures for Electrical Equipment. UL 50, Copywrite 1995. *Our enclosures are tested to CSA Standards by Underwriters Laboratories and bear the CUL Listing Mark. Underwriters Laboratories Inc. (UL) shall not be responsible for the use of or reliance upon a UL Standard by anyone. UL shall not incur any obligation or liability for damages, including consequential damages, arising out of or connection with the use, interpretation of or reliance upon a UL Standard. The definitions on this page are reproduced with permission from CSA. These descriptions are not intended to be complete representations of CSA standards. (NEMA Standard 7-15-1991) TYPE 3 Enclosures are intended for outdoor use primarily to provide a degree of protection against rain, sleet, windblown dust, and damage from external ice formation. (NEMA Standard 7-15-1991) TYPE 3R TYPE 4 Enclosures are intended for outdoor use primarily to provide a degree of protection against rain, sleet, and damage from external ice formation. (NEMA Standard 7-15-1991) Enclosures are intended for indoor and outdoor use primarily to provide a degree of protection against windblown dust and rain, splashing water, hose-directed water, and damage from external ice formation. (NEMA Standard 1-10-1979) TYPE 4X TYPE 12 (NEMA Standard 7-15-1991) TYPE 13 DISCLAIMERS NEMA & UL RATINGS 30 30 INDEX PAGE # 6003 . . . . . . . . . . . . . . . . . . . . . . . . . . . . .29 6116 . . . . . . . . . . . . . . . . . . . . . . . . . . . . .29 105J . . . . . . . . . . . . . . . . . . . . . . . . . . . . .26 307220-TC3R-WB . . . . . . . . . . . . . . . . . .24 363616-CT3R-WB . . . . . . . . . . . . . . . . . .24 403214-TC3R-SP1 . . . . . . . . . . . . . . . . .24 543214-TC3R-SP1 . . . . . . . . . . . . . . . . .24 5T8K2 . . . . . . . . . . . . . . . . . . . . . . . . . . .29 A7514 . . . . . . . . . . . . . . . . . . . . . . . . . . .28 A7515 . . . . . . . . . . . . . . . . . . . . . . . . . . .28 A7516 . . . . . . . . . . . . . . . . . . . . . . . . . . .28 A7517 . . . . . . . . . . . . . . . . . . . . . . . . . . .28 A7518 . . . . . . . . . . . . . . . . . . . . . . . . . . .28 A7551 . . . . . . . . . . . . . . . . . . . . . . . . . . .28 A8110 . . . . . . . . . . . . . . . . . . . . . . . . . . .28 A8111 . . . . . . . . . . . . . . . . . . . . . . . . . . .28 A8112 . . . . . . . . . . . . . . . . . . . . . . . . . . .28 A9064 . . . . . . . . . . . . . . . . . . . . . . . . . . .28 CP-16FPAD . . . . . . . . . . . . . . . . . . . . . . .26 CP-16PDMNT-CALT . . . . . . . . . . . . . . . .26 CP-21 . . . . . . . . . . . . . . . . . . . . . . . . . . .29 CP-24PDMNT-CALT . . . . . . . . . . . . . . . .26 CP-32PDMNT . . . . . . . . . . . . . . . . . . . . .26 CP-ABK/8 . . . . . . . . . . . . . . . . . . . . . . . .26 CP-PE-HOA-3POS . . . . . . . . . . . . . . . . .26 CP-TC24H . . . . . . . . . . . . . . . . . . . . . . . .26 CP-TC7D . . . . . . . . . . . . . . . . . . . . . . . . .26 CP-TCWIRE . . . . . . . . . . . . . . . . . . . . . .26 K1047 . . . . . . . . . . . . . . . . . . . . . . . . . . .28 K1190 . . . . . . . . . . . . . . . . . . . . . . . . . . .29 K1350 . . . . . . . . . . . . . . . . . . . . . . . .19, 28 K1350L . . . . . . . . . . . . . . . . . . . . . . . . . .28 K1539 . . . . . . . . . . . . . . . . . . . . . . . .19, 28 K1540 . . . . . . . . . . . . . . . . . . . . . . . .19, 28 K1540L . . . . . . . . . . . . . . . . . . . . . . . . . .28 K1541 . . . . . . . . . . . . . . . . . . . . . . . .19, 28 K2381 . . . . . . . . . . . . . . . . . . . . . . . . . . .29 K3082 . . . . . . . . . . . . . . . . . . . . . . . . . . .28 K3083 . . . . . . . . . . . . . . . . . . . . . . . . . . .28 K3441 . . . . . . . . . . . . . . . . . . . . . . . . . . .28 K3442 . . . . . . . . . . . . . . . . . . . . . . . . . . .28 K3865 . . . . . . . . . . . . . . . . . . . . . . . . . . .26 K3865 . . . . . . . . . . . . . . . . . . . . . . . . . . .29 K3866 . . . . . . . . . . . . . . . . . . . . . . . . . . .29 K4802 . . . . . . . . . . . . . . . . . . . . . . . . . . .28 K4977-INT . . . . . . . . . . . . . . . . . . . . . . . .28 K5022-INT . . . . . . . . . . . . . . . . . . . . . . . .28 K5T . . . . . . . . . . . . . . . . . . . . . . . . . . . . .29 K8180 . . . . . . . . . . . . . . . . . . . . . . . . . . .28 M400-UG-APS-LC . . . . . . . . . . . . . . . . . .15 M5-144 . . . . . . . . . . . . . . . . . . . . . . . . . .29 MCP . . . . . . . . . . . . . . . . . . . . . . . . . . . . .29 MR-2 . . . . . . . . . . . . . . . . . . . . . . . . . . . .29 CATALOG # PAGE # MR-4 . . . . . . . . . . . . . . . . . . . . . . . . . . . .29 Q2100 . . . . . . . . . . . . . . . . . . . . . . . . . . .11 Q2100H . . . . . . . . . . . . . . . . . . . . . . . . . .11 Q260 . . . . . . . . . . . . . . . . . . . . . . . . . . . .11 Q260H . . . . . . . . . . . . . . . . . . . . . . . . . . .11 QN2150 . . . . . . . . . . . . . . . . . . . . . . . . . .11 QN2150H . . . . . . . . . . . . . . . . . . . . . . . . .11 QN2200 . . . . . . . . . . . . . . . . . . . . . . . . . .11 QN2200H . . . . . . . . . . . . . . . . . . . . . . . . .11 S8324 . . . . . . . . . . . . . . . . . . . . . . . . . . .28 U1252-REL-K1 . . . . . . . . . . . . . . . . . . . .16 U1253-X . . . . . . . . . . . . . . . . . . . . . . . . .16 U1254-X . . . . . . . . . . . . . . . . . . . . . . . . .16 U1255-X . . . . . . . . . . . . . . . . . . . . . . . . .16 U1256-X . . . . . . . . . . . . . . . . . . . . . . . . .16 U1797-O-K3L-K2L . . . . . . . . . . . . . . . . . . .9 U1980-O . . . . . . . . . . . . . . . . . . . . . . . . . .7 U2120-X . . . . . . . . . . . . . . . . . . . . . . . . .10 U2594-X . . . . . . . . . . . . . . . . . . . . . . . . .10 U2852-X . . . . . . . . . . . . . . . . . . . . . . . . .19 U2853-X . . . . . . . . . . . . . . . . . . . . . . . . .19 U2854-X . . . . . . . . . . . . . . . . . . . . . . . . .19 U2855-X . . . . . . . . . . . . . . . . . . . . . . . . .19 U2856-X . . . . . . . . . . . . . . . . . . . . . . . . .19 U2862-X . . . . . . . . . . . . . . . . . . . . . . . . .19 U2863-X . . . . . . . . . . . . . . . . . . . . . . . . .19 U2864-X . . . . . . . . . . . . . . . . . . . . . . . . .19 U2865-X . . . . . . . . . . . . . . . . . . . . . . . . .19 U2866-X . . . . . . . . . . . . . . . . . . . . . . . . .19 U3313-X-2/K3 . . . . . . . . . . . . . . . . . . . . . .9 U3822-20GWR . . . . . . . . . . . . . . . . . . . . .6 U3830 . . . . . . . . . . . . . . . . . . . . . . . . . . . .5 U3860 . . . . . . . . . . . . . . . . . . . . . . . . . . . .5 U4252-RXL-K2 . . . . . . . . . . . . . . . . . . . .16 U4413-O . . . . . . . . . . . . . . . . . . . . . . . . . .7 U4419-X . . . . . . . . . . . . . . . . . . . . . . . . . .9 U4505-X . . . . . . . . . . . . . . . . . . . . . . . . . .9 U4581-RL-QG . . . . . . . . . . . . . . . . . . . . . .8 U4701-RL-QG . . . . . . . . . . . . . . . . . . . . . .8 U4702-X . . . . . . . . . . . . . . . . . . . . . . . . . .9 U4835-X-2/200-BL . . . . . . . . . . . . . . . . . .14 U4881-O . . . . . . . . . . . . . . . . . . . . . . . . . .6 U4881-O-50GB . . . . . . . . . . . . . . . . . . . . .6 U4881-O-60GB . . . . . . . . . . . . . . . . . . . . .6 U4908-O . . . . . . . . . . . . . . . . . . . . . .21, 22 U5059-X-2/200-K3L . . . . . . . . . . . . . . . . .14 U5101-XL . . . . . . . . . . . . . . . . . . . . .21, 22 U5136-O . . . . . . . . . . . . . . . . . . . . . . . . .23 U5136-O-100S . . . . . . . . . . . . . . . . . . . .23 U5136-O-200S . . . . . . . . . . . . . . . . . . . .23 U5137-O . . . . . . . . . . . . . . . . . . . . . . . . .23 U5137-O-100S . . . . . . . . . . . . . . . . . . . .23 U5137-O-200S . . . . . . . . . . . . . . . . . . . .23 31 CATALOG # PAGE # U5168-XTL-200 . . . . . . . . . . . . . . . . . . . .12 U5268-XTL-200 . . . . . . . . . . . . . . . . . . . .12 U5750-RXL-200-BL . . . . . . . . . . . . . . . . .13 U5842-RL-100 . . . . . . . . . . . . . . . . . . . . .11 U5842-RL-200 . . . . . . . . . . . . . . . . . . . . .11 U5844-PXL . . . . . . . . . . . . . . . . . . . . . . .11 U5844-PXL-100 . . . . . . . . . . . . . . . . . . . .11 U5844-PXL-150 . . . . . . . . . . . . . . . . . . . .11 U5844-PXL-200 . . . . . . . . . . . . . . . . . . . .11 U5882-X . . . . . . . . . . . . . . . . . . . . . . . . .17 U5883-X . . . . . . . . . . . . . . . . . . . . . . . . .17 U5884-X . . . . . . . . . . . . . . . . . . . . . . . . .17 U5885-X . . . . . . . . . . . . . . . . . . . . . . . . .17 U5886-X . . . . . . . . . . . . . . . . . . . . . . . . .17 U5890-X-2/200 . . . . . . . . . . . . . . . . . . . .14 U5892-X-2/200 . . . . . . . . . . . . . . . . . . . .14 U5894-X-2/200-MLK . . . . . . . . . . . . . . . .14 U5902-X . . . . . . . . . . . . . . . . . . . . . . . . .17 U5903-X . . . . . . . . . . . . . . . . . . . . . . . . .17 U5904-X . . . . . . . . . . . . . . . . . . . . . . . . .17 U5905-X . . . . . . . . . . . . . . . . . . . . . . . . .17 U5906-X . . . . . . . . . . . . . . . . . . . . . . . . .17 U7021-RG-TG . . . . . . . . . . . . . . . . . . . . . .7 U7040-RL-TG . . . . . . . . . . . . . . . . . . . . . .7 U8212-RL . . . . . . . . . . . . . . . . . . . . . . . .16 U8213-RL . . . . . . . . . . . . . . . . . . . . . . . .16 U8214-RL . . . . . . . . . . . . . . . . . . . . . . . .16 U8215-RL . . . . . . . . . . . . . . . . . . . . . . . .16 U8216-RL . . . . . . . . . . . . . . . . . . . . . . . .16 U8435-RL-TG . . . . . . . . . . . . . . . . . . . . . .7 UQFB-M-200 . . . . . . . . . . . . . . . . . . . . . .13 UQFP-100 . . . . . . . . . . . . . . . . . . . . . . . .27 UQFP-125 . . . . . . . . . . . . . . . . . . . . . . . .27 UQFP-150 . . . . . . . . . . . . . . . . . . . . . . . .27 UQFP-175 . . . . . . . . . . . . . . . . . . . . . . . .27 UQFP-200 . . . . . . . . . . . . . . . . . . . . . . . .27 UQFPH-100 . . . . . . . . . . . . . . . . . . . . . . .27 UQFPH-125 . . . . . . . . . . . . . . . . . . . . . . .27 UQFPH-150 . . . . . . . . . . . . . . . . . . . . . . .27 UQFPH-175 . . . . . . . . . . . . . . . . . . . . . . .27 UQFPH-200 . . . . . . . . . . . . . . . . . . . . . . .27 UQFPH-M-100 . . . . . . . . . . . . . . . . . .23, 27 UQFPH-M-125 . . . . . . . . . . . . . . . . . . . . .27 UQFPH-M-150 . . . . . . . . . . . . . . . . . . . . .27 UQFPH-M-175 . . . . . . . . . . . . . . . . . . . . .27 UQFPH-M-200 . . . . . . . . . . . . . . . . . .23, 27 UQFP-M-100 . . . . . . . . . . . . . . . . . . . . . .27 UQFP-M-125 . . . . . . . . . . . . . . . . . . . . . .27 UQFP-M-150 . . . . . . . . . . . . . . . . . . . . . .27 UQFP-M-175 . . . . . . . . . . . . . . . . . . . . . .27 UQFP-M-200 . . . . . . . . . . . . . . . . . . . . . .27 USE-22-200-MB . . . . . . . . . . . . . . . . . . .13 USE-AP-200-M . . . . . . . . . . . . . . . . . . . .13 INDEX CATALOG # 31 CONDUIT AND AMPACITY INFORMATION MAXIMUM NUMBER OF CONDUCTORS IN CONDUIT u CONDUIT AND AMPACITY INFORMATION 32 Table from 2008 NEC Code Reference: Rigid Metal Conduit CONDUCTOR SIZE TYPE (AWG / kcmil) 12 10 8 6 4 3 2 1 1/0 2/0 3/0 4/0 4 2 1/0 2/0 4/0 250 350 500 750 THHN, THWN, THWN-2 XHH, XHHW, XHHW-2 u This CONDUIT TRADE SIZES (INCHES) 1 3 ⁄2 9 6 3 2 1 1 1 1 1 0 0 0 1 1 1 0 0 0 0 0 0 ⁄4 1 11⁄4 11⁄2 2 16 10 6 4 2 1 1 1 1 1 1 1 2 1 1 1 1 0 0 0 0 26 17 9 7 4 3 3 1 1 1 1 1 4 3 1 1 1 1 1 0 0 46 29 16 12 7 6 5 4 3 2 1 1 7 5 3 2 1 1 1 1 0 62 39 22 16 10 8 7 5 4 3 3 2 10 7 4 3 2 1 1 1 1 102 64 37 27 16 14 11 8 7 6 5 4 16 12 7 6 4 3 2 1 1 AL or 31⁄2 3 146 225 301 92 142 189 82 109 53 79 59 38 48 36 23 41 31 20 34 26 17 25 19 12 21 16 10 18 13 8 15 11 7 12 9 6 49 37 24 35 26 17 22 16 10 18 13 9 12 9 6 10 7 5 7 6 3 5 4 2 4 3 1 4 387 244 140 101 62 53 44 33 27 23 19 16 63 45 28 23 16 13 10 7 5 table is for concentric stranded conductors only. For cables with compact conductors refer to NEC. Refer to latest NEC Code or Local Codes for updated requirements. * ALLOWABLE AMPACITIES OF INSULATED COPPER & ** ALUMINUM CONDUCTORS (3W IN CONDUIT) 75°C (167°F) *CU 21⁄2 **Cu-Clad AL A B A C 18 16 14 12 10 8 – – 20✝ 25✝ 35✝ 50 – – – 12 10 8 – – – 20✝ 30✝ 40 6 4 3 2 1 65 85 100 115 130 6 4 3 2 1 50 65 75 90 100 1/0 2/0 3/0 4/0 150 175 200 230 1/0 2/0 3/0 4/0 120 135 155 180 250 300 350 400 500 255 285 310 335 380 250 300 350 400 500 205 230 250 270 310 600 700 750 420 460 475 600 700 750 340 375 385 AMPACITY CORRECTION FACTORS A = Size: AWG/MCM *B = Ampere Rating for Insulation Types: FEPW, RH, RHW, THW, THWN, XHHW, USE, 2W. **C = Ampere Rating for Insulation Types: RH, RHW, THW, THWN, XHHW, USE (Per NEC table 310-16) AMBIENT TEMP.C° 21 - 25 26 - 30 31 - 35 36 - 40 41 - 45 46 - 50 51 - 55 56 - 60 61 - 65 CORRECTION FACTOR 1.05 1.00 .94 .88 .82 .75 .67 .58 .33 AMBIENT TEMP.F° 70 - 77 78 - 86 87 - 95 96 - 104 105 - 113 114 - 122 123 - 131 132 - 140 141 - 158 Overall ampere ratings of U/L listed Milbank multiple position meter sockets are based on 2008 N.E.C. Handbook Article 220-84 and ANSI / UL-414 (except where restricted by line connector size.) These requirements provide for a diversity factor / demand factor being utilized in determining the overall (main bus / lug) rating of a gang socket. All Milbank U/L listed gang sockets meet or exceed these diversity factor/demand factor requirements. Standard overall ampacity ratings for U/L listed and non U/L listed gang sockets are as shown in the chart below. Ampere ratings of meter sockets are based on the meter socket being wired with 75° C insulated wire conductor, sized in accordance with Table 310-16 of the National Electric Code. GANG SOCKET OVERALL AMPACITIES NO. OF METER POSITIONS 2 3 4 5 6 100A / POS. AMPACITY 200A 200A 200A 225A 270A 125A / POS. AMPACITY 200A 225A 250A 285A 330A 150A / POS. AMPACITY 200A 225A 270A 338A 396A 200A / POS. AMPACITY 400A 270A 360A 450A 528A ✝ Unless otherwise permitted elsewhere in the Code, the overcurrent protection for conductor types marked with an obelisk (✝) shall not exceed 15 amps for 14 AWG, 20 amps for 12 AWG, and 30 amps for 10 AWG copper: or 15 amps for 12 AWG and 25 amps for 10 AWG aluminum and copper-clad aluminum after any correction factors for ambient temperature and number of conductors have been applied. 32 ENERGIZATION OF ELECTRICAL EQUIPMENT In addition to national and local electrical codes, many utilities have specific requirements for metering equipment. Always consult the serving utility for their specifications and requirements prior to ordering or installing Milbank meter mounting equipment. BEFORE ENERGIZING A. Give equipment a thorough visual examination to determine that: 1) No shipping or installation damage exists. 2) Proper clearances have been maintained. 3) All connections have been made. 4) Equipment is clean and dry. B. Make a thorough examination to: 1) Verify tightness of all bolted connections (see table below). 2) Manually operate all circuit breakers, switches, relays, etc. 3) Check rigidity of all mountings, bus bars and components. 4) Use test equipment to check continuity of circuitry and integrity of insulation. C. All switches and circuit breakers should be in the “off” position. D. Verify that manual meter bypass (if applicable) is in non-bypass position. E. Install cover and/or close doors. F. If installation is not being energized at this time, follow “after-energizing” steps listed below. These steps will secure the installation in case of accidental energization. WHEN ENERGIZING A. Use caution and follow established safety procedures: 1) Wear safety apparel. 2) Use safety equipment. 3) Take action to prevent injury to yourself and others in the event of failure of the installation. 4) Take action to prevent/decrease damage to property in the event of failure of the installation. 5) If you are unsure how to safely energize the installation, get someone who is knowledgeable to do it. AFTER ENERGIZING A. Secure the installation: 1) To prevent accidental contact with energized parts, cover all openings with approved filler devices. 2) To prevent unauthorized access, secure all covers and/or doors with approved security devices. 3) Attach/post information to advise others of potential hazards associated with the installation. RECOMMENDED TORQUE FOR GENERAL APPLICATIONS* JOINT DESCRIPTION NOMINAL SIZE SCREW NUT 10 10 10 12 12 1/4 1/4 5/16 5/16 3/8 1/2 BRASS STEEL STEEL STEEL STEEL STEEL STEEL STEEL STEEL STEEL STEEL Brass Nut or Extruded Hole CU or AL Busbar <1/8″ Steel Nut or EH; CU or AL Busbar >1/8″ Aluminum Extruded Hole Steel Nut or Extruded Hole Aluminum Extruded Hole Steel Nut or EH; CU or AL Busbar Aluminum Extruded Hole Steel Nut or EH; CU or AL Busbar Steel Nut Steel Nut HEAD TYPE TORQUE ( INCH LBS. ) ALL ALL ALL ALL ALL ALL ALL HEX HEX HEX HEX 20-25 in. lbs. 25-30 in. lbs 30-35 in. lbs 30-35 in. lbs 40-50 in. lbs. 40-50 in. lbs. 50-60 in. lbs. 60-70 in. lbs. 100-150 in. lbs. 150-200 in. lbs. 200-250 in. lbs. *Interior labels typically indicate the required torque for wire connectors and studs, and should be referenced first. EH: Extruded Hole CU: Copper AL: Aluminum 33 ENERGIZATION OF ELECTRICAL EQUIPMENT IMPORTANT NOTE 33 MATERIALS AND FINISHES 34 MATERIALS AND FINISHES MATERIALS STEEL QUALITY The meter equipment listed in this catalog is made of galvanized steel (AISI* G90) to afford the best possible weather proofing. *American Iron and Steel Institute. STEEL SHEET 16 gauge, galvanized, sheet: 0.90 oz./ sq.ft. class zinc-coated. (AISI G90) 14 gauge, galvanized, sheet: 0.90 oz./ sq.ft. class zinc-coated. ALUMINUM EXTRUSION Wire-Terminals: Alloy; 6061-T6, Tin-plated for CU/AL wire. Bus Bar: Alloy; 6101-o & 6063-O ALUMINUM SHEET 3000 series aluminum sheet, H14, or 5052 series aluminum sheet, H32. Where applicable thicknesses range from .064 – .125 COPPER SHEET & BUS Electrolytic copper with tin plating in most applications. INSULATING MATERIALS • In most units, support bases for current-carrying components are molded from fiberglass reinforced high-strength, track resistant, thermoset polyester molding compounds. • Clear or black safety shields and polarity barriers are molded from high-strength, track resistant, polycarbonate molding compounds. • Various sheet insulating materials, as appropriate for the application are utilized in the fabrication of flat, formed and punched component parts and barriers. FINISH PROCESS Light gray “state of the art” electrostatically applied powder paint offers a durable, non-fading finish. For further information concerning the chemical analysis of the weather resistant finish, please contact the factory. METAL FASTENERS Zinc-coated with a chromate dip. RATING NEMA RATING All Milbank meter sockets, CT cans and meter socket / breaker units have a type 3R rating. 34 ADDITIONAL MILBANK PRODUCTS Commercial Pedestals • Attractive • Easy to install • Secure • Cost effective UnStrut Your Stuff... 816.483.5314 phone 816.483.6357 fax www.milbankmfg.com ComPed 2/09 (7.5K) In addition to your local utility’s meter mounting equipment, Milbank also manufactures supporting products, such as... Air Conditioner Disconnects Hot Tub Disconnects RV/Mobile Home Power Outlets Terminal Boxes Temporary Power Outlets Commercial Pedestals Commercial Enclosures CT Enclosures Circuit Breakers Enclosed Circuit Breakers Safety Switches Test Switches Contact your local distributor or go to www.milbankmfg.com to find additional product literature. 35 ADDITIONAL MILBANK PRODUCTS Other quality products available from Milbank 35 Meter Mounting Equipment & More! Commercial Electrical Enclosures Residential & Commercial Metering Commercial Meter Pedestals Disconnect Devices Current Transformer Enclosures RV/MH Pedestals Temporary Power Outlets Circuit Breakers Distribution Unit Substations Enclosed Circuit Breakers Safety Switches Test Switches PORTER SALES 6001 Murray Street Little Rock, AR 72209 Tel: 501-570-8100 Fax: 501-570-8190 MILBANK MFG. CO. PO Box 419028 Kansas City, MO 64141-0028 Tel: 816-483-5314 Fax: 816-483-6357 Toll Free: 877-483-5314 www.milbankmfg.com www.milbankmfg.com ARK/WTN/NMS 3/11 ( 750 )
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.7 Linearized : Yes Author : Kim Tappan Create Date : 2011:03:23 11:12:23-05:00 GTS PDFX Conformance : PDF/X-1a:2001 GTS PDFX Version : PDF/X-1:2001 Modify Date : 2011:03:23 11:16:06-05:00 Has XFA : No XMP Toolkit : Adobe XMP Core 4.2.1-c043 52.372728, 2009/01/18-15:56:37 Producer : Acrobat Distiller 9.4.2 (Macintosh) Trapped : False Creator Tool : QuarkXPress 8.1.6 Metadata Date : 2011:03:23 11:16:06-05:00 Format : application/pdf Creator : Kim Tappan Title : Arkansas_3-2011_Layout 1 Document ID : uuid:ac1a00d2-6cdc-cc49-91d5-ca477da96e8f Instance ID : uuid:7a594cc3-71ba-4d42-8bd1-d7e815ccd474 Page Count : 36EXIF Metadata provided by EXIF.tools