Volume 6 Tab 2 54525 Catalog

102556-Catalog 102556-Catalog 102556-Catalog 786685 Batch10 unilog cesco-content

103068-Catalog 103068-Catalog 103068-Catalog 786685 Batch10 unilog cesco-content

449624-Catalog 1 449624-Catalog_1 449624-Catalog_1 786685 Batch10 unilog cesco-content

119852-Catalog 119852-Catalog 119852-Catalog 786685 Batch10 unilog cesco-content

119431-Catalog 119431-Catalog 119431-Catalog 786685 Batch10 unilog cesco-content

2014-10-17

: Pdf 54525-Catalog 54525-Catalog 782116 Batch10 unilog

Open the PDF directly: View PDF PDF.
Page Count: 291

DownloadVolume 6 Tab 2  54525-Catalog
Open PDF In BrowserView PDF
Adjustable Frequency Drives
PowerXL DC1

OEM Drives

2.1

Product Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

2.2

V6-T2-11

V6-T2-20

2
2

General Purpose Industrial Drives

2

2.4

2

PowerXL DG1 Series Drives
Product Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

2.5

V6-T2-30

SVX9000 Drives
Product Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

V6-T2-45

SVX9000 Drives
Product Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

V6-T2-48

SVX9000 Enclosed Drives
Product Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

V6-T2-87

SVX9000 VFD Pump Panels
Product Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

V6-T2-111

2.6

H-Max Series Drives

2.9

2
2
2

V6-T2-132

H-Max IntelliPass and IntelliDisconnect Drives
Product Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

2

V6-T2-141

2

V6-T2-158

Enclosed Passive Filtered Drives
Product Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

V6-T2-200

Enclosed 18-Pulse Drives
Product Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

V6-T2-233

LCX9000 Liquid Cooled Drives
V6-T2-263

2
2
2
2
2

SPA9000/SPN9000/SPI9000 Common DC Bus Drives
Product Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

2
2

Low Harmonic Drives

Drawings
Online

2

2

SPX9000 Drives

Learn
Online

2

H-Max Drives
Product Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Product Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

2.10

2

V6-T2-131

Product Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

2.8

2

Product Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Performance Drives

2.7

2

2

General Purpose HVAC Drives
Enclosed 18-Pulse Drive

2
2

M-Max Series Drives
Product Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

PowerXL DG1

V6-T2-2

PowerXL DA1 Series Drives
Product Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

2.3

2

PowerXL DC1 Series Drives

V6-T2-280

2
2

An Eaton
Green Solution

2
2

Volume 6—Solid-State Motor Control CA08100007E—May 2014 www.eaton.com

V6-T2-1

2.1
2

Adjustable Frequency Drives
PowerXL DC1 Series Drives

Contents

PowerXL DC1 Series Drives

Description

2

Page

PowerXL DC1 Series Drives
Catalog Number Selection . . . . . . . . . . . . . . . .
Product Selection . . . . . . . . . . . . . . . . . . . . . . .
Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . .
Technical Data and Specifications . . . . . . . . . .
Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . .

2
2
2

V6-T2-3
V6-T2-4
V6-T2-6
V6-T2-7
V6-T2-9

2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2

Product Description

Features

Eaton’s PowerXL™ DC1
variable frequency drives are
the next generation of drives
specifically engineered for
today’s machinery
applications.

●

The DC1 is compact with
only 14 basic parameters,
SmartWire-DT™ connectivity,
and outstanding ease of
mounting and installation.
The DC1 is perfect for quick
commissioning and is ideal
for panel builders. This drive
supports single-phase motor
applications, and detachable
terminal blocks make control
wiring much easier.

●

●

●

●

●

Compact, space-saving
design
Rugged and reliable—175%
for 2s, 50°C rated
DIN rail and screw
mountable (FS1 and FS2)
Side-by-side installation
Industry-leading efficiency
delivers energy savings to
the customer
Optional integrated EMC
filters make the unit
suitable for commercial
and industrial networks

●

●
●

●
●
●

●

●

Brake chopper as standard
in frames 2 and higher
Temperature-controlled fan
RS-485/Modbus® and
CANopen™ as standard
PI controller as standard
SmartWire capability
Removable I/O terminal
blocks
Contactor style power
wiring
Compatibility with singlephase motors

Models rated at 480 volts,
three-phase, 50/60 Hz are
available in sizes ranging from
1 to 15 hp. Models rated at
240 volts, single- or threephase, 50/60 Hz are available
in sizes ranging from 0.5
to 7.5 hp. Models rated at
115 volts, single-phase,
50/60 Hz are available in
the 0.5 to 3 hp size range.

2
2
2
2
2
V6-T2-2

Volume 6—Solid-State Motor Control CA08100007E—May 2014 www.eaton.com

Standards and
Certifications
Product
●
Complies with EN61800-3
(2004)
EMC (At Default Settings)
●
EMC Category C1, C2
and C3 at default settings
(1m, 5m, 25m)
Safety 1
●
61800-5-1
●
EN 60529
●
CE
●
UL
●
cUL
●
UkrSepro
●
c-Tick
●
RoHS compliant

Note
1 See unit nameplate for more detailed
approvals.

Adjustable Frequency Drives
PowerXL DC1 Series Drives

2.1

Catalog Number Selection

2

DC1 Series Adjustable Frequency AC Drives

2

DC1 - 1 2 4D1 F N - A 20 N
Device Series
DC1 = Variable frequency drive, compact, Series 1
(D = Drives, C = Compact, 1 = Series 1)

2

Type
N = Standard basic device

Connection in Power Section
1 = Single-phase mains connection/three-phase motor connection
3 = Three-phase mains connection/three-phase motor connection
S = Single-phase mains connection/single-phase motor connection

1=
2=
4=
D=

2

Mains Voltage Category
110V (110–115V ±10%)
230V (200–240V ±10%)
460V (380–480V ±10%)
110V input/230V output (voltage doubler)

Rated
Operational Current
Examples—
2D2 = 2.2A
4D1 = 4.1A
024 = 24A

2

Degree of Protection
20 = IP20/NEMA 0
66 = IP66/NEMA 4
6S = IP66 with disconnect/NEMA 4

2
2
2

Display Unit (Display)
A = LED display

2

Brake Chopper
N = No internal brake chopper
B = Brake chopper

2
2

EMC (Radio Interference Suppression Filter)
N = No internal RFI filter
F = Internal RFI filter

2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2

Volume 6—Solid-State Motor Control CA08100007E—May 2014 www.eaton.com

V6-T2-3

2.1
2
2

Adjustable Frequency Drives
PowerXL DC1 Series Drives

Product Selection
IP20

2

DC1 Series IP20 Enclosure Drives 1
hp 2

kW

Volts

0.5

0.37

2

0.75

0.55

115V single-phase in/
115V single-phase out

2

0.5

0.37

1

0.75

2

1.5

1.1

0.5

0.37

2

1

0.75

1.5

1.1

2

0.5

0.37

2

1

0.75

2

2

200–240V single-phase in/
200–240V single-phase out

115V single-phase in/
230V three-phase out

100% Continuous Frame
Current In (A)
Size 3

Catalog Number

7

1

DC1-S17D0NN-A20N

10.5

2

DC1-S1011NB-A20N

4.3

1

DC1-S24D3NN-A20N 4

7

1

DC1-S27D0NN-A20N 4

10

2

DC1-S2011NB-A20N 4

2.3

1

DC1-1D2D3NN-A20N 4

4.3

1

DC1-1D4D3NN-A20N

5.8

2

DC1-1D5D8NB-A20N

2.3

1

DC1-122D3NN-A20N 4

4.3

1

DC1-124D3NN-A20N 4

1.5

7

1

DC1-127D0NN-A20N 4

2

1.5

7

2

DC1-127D0NB-A20N 4

3

2.2

10.5

2

DC1-12011NB-A20N 4

2

5

4

15

3

DC1-12015NB-A20N

2

0.5

0.37

2.3

1

DC1-322D3NN-A20N

1

0.75

4.3

1

DC1-324D3NN-A20N

2

2

1.5

7

1

DC1-327D0NN-A20N

2

1.5

7

2

DC1-327D0NB-A20N 4

2

3

2.2

10.5

2

DC1-32011NB-A20N 4

5

4

18

3

DC1-32018NB-A20N 4

2

1

0.75

2.2

1

DC1-342D2NN-A20N 4

2

2

1.5

4.1

1

DC1-344D1NN-A20N 4

2

1.5

4.1

2

DC1-344D1NB-A20N 4

2

3

2.2

5.8

2

DC1-345D8NB-A20N 4

5

4

9.5

2

DC1-349D5NB-A20N 4

2

7.5

5.5

14

3

DC1-34014NB-A20N 4

10

7.5

18

3

DC1-34018NB-A20N 4

2

15

11

24

3

DC1-34024NB-A20N 4

200–240V single-phase in/
230V three-phase out

200–240V three-phase in/
230V three-phase out

380–480V three-phase in/
460V three-phase out

Notes
1 These are constant torque/high overload rated drives.
2 For all applications, select the unit such that the motor current is less than or equal to the rated continuous output current.
3 Brake chopper circuit available as standard in frames 2 and 3.
4 RFI version available. Substitute with DC1-*****F*-**** for this option.

2
2
2
2
2
2
2
2
2
2
2
V6-T2-4

Volume 6—Solid-State Motor Control CA08100007E—May 2014 www.eaton.com

Adjustable Frequency Drives
PowerXL DC1 Series Drives

IP66

IP66S

2.1

DC1 Series IP66 Enclosure Drives 1

2

100% Continuous Frame
Current In (A)
Size 3

Catalog Number

7

1

DC1-S17D0NN-A6SN 4

10.5

2

DC1-S1011NB-A6SN 4

4.3

1

DC1-S24D3NN-A6SN 45

7

1

DC1-S27D0NN-A6SN 45

10

2

DC1-S2011NB-A6SN 45

2.3

1

DC1-1D2D3NN-A6SN 4

4.3

1

DC1-1D4D3NN-A6SN 4

5.8

2

DC1-1D5D8NB-A6SN 4

2.3

1

DC1-122D3NN-A6SN 45

4.3

1

DC1-124D3NN-A6SN 45

1.5

7

1

DC1-127D0NN-A6SN 45

2

1.5

7

2

DC1-127D0NB-A6SN 45

3

2.2

10.5

2

DC1-12011NB-A6SN 45

5

4

15

3

DC1-12015NB-A6SN 4

0.5

0.37

2.3

1

DC1-322D3NN-A6SN 4

1

0.75

4.3

1

DC1-324D3NN-A6SN 4

2

1.5

7

1

DC1-327D0NN-A6SN 4

2

1.5

7

2

DC1-327D0NB-A6SN 45
45

hp 2

kW

Volts

0.5

0.37

0.75

0.55

115V single-phase in/
115V single-phase out

0.5

0.37

1

0.75

1.5

1.1

0.5

0.37

1

0.75

1.5

1.1

0.5

0.37

1

0.75

2

200–240V single-phase in/
200–240V single-phase out

115V single-phase in/
230V three-phase out

200–240V single-phase in/
230V three-phase out

200–240V three-phase in/
230V three-phase out

3

2.2

10.5

2

DC1-32011NB-A6SN

5

4

18

3

DC1-32018NB-A6SN 45

1

0.75

2

1.5

2
3
5

380–480V three-phase in/
460V three-phase out

2
2
2
2
2
2
2
2
2
2
2
2
2

45

2.2

1

DC1-342D2NN-A6SN

4.1

1

DC1-344D1NN-A6SN 45

1.5

4.1

2

DC1-344D1NB-A6SN 45

2.2

5.8

2

DC1-345D8NB-A6SN 45

4

9.5

2

DC1-349D5NB-A6SN 45
45

7.5

5.5

14

3

DC1-34014NB-A6SN

10

7.5

18

3

DC1-34018NB-A6SN 45

2
2
2
2

Notes
1 These are constant torque/high overload rated drives.
2 For all applications, select the unit such that the motor current is less than or equal to the rated continuous output current.
3 Brake chopper circuit available as standard in frames 2 and 3.
4 Non-disconnect version available. Substitute with -A66N.
5 RFI version available. Substitute with DC1-*****F*-**** for this option.

2
2
2
2
2
2
2
2
2
2
2
2

Volume 6—Solid-State Motor Control CA08100007E—May 2014 www.eaton.com

V6-T2-5

2.1
2
2
2
2
2
2

Adjustable Frequency Drives
PowerXL DC1 Series Drives

Accessories
DC1 Series
PC Communication Kit and Copy/Paste Module

Extension Cables and Data Cable Splitter

Description

Catalog Number

Description

Catalog Number

Bluetooth copy/paste communication stick

DX-COM-STICK

RJ45 communication cable w/terminating resistor

DX-CBL-TERM

USB PC connection kit

DX-COM-PCKIT

RS-485 data cable, RJ45, 0.5m

DX-CBL-RJ45-0M5

RS-485 data cable, RJ45, 1.0m

DX-CBL-RJ45-1M0

RS-485 data cable, RJ45, 3.0m

DX-CBL-RJ45-3M0

RS-485 three-way data cable splitter, RJ45

DX-SPL-RJ45-3SL

RS-485 data cable splitter, RJ45, (1 connector to 2 socket)

DX-SPL-RJ45-2SL1PL

Encoder Feedback Plug-In Option Module
and Miscellaneous Cards
Description

Catalog Number

Local control/test option card

DXC-EXT-LOCSIM

2

HVACO drive running and tripped relay output card

DXC-EXT-2RO1AO

SmartWire Modules

Dual relay output card

DXC-EXT-2RO

Description

Catalog Number

2

110V logic input card

DXC-EXT-IO110

SmartWire-DT interface for DC1 IP20

DX-NET-SWD3

230V logic input card

DXC-EXT-IO230

2

2
2
2
2

Note
1 Includes 1m RS-485 data cable.

Remote Keypad
Description

Catalog Number

LED remote keypad—7-segment display, IP54 rated

DX-KEY-LED 1

OLED remote keypad—full text display, multi-line text,
multi-language, IP54

DX-KEY-OLED 1

2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
V6-T2-6

Volume 6—Solid-State Motor Control CA08100007E—May 2014 www.eaton.com

Adjustable Frequency Drives
PowerXL DC1 Series Drives

2.1

Technical Data and Specifications

2

DC1 Series
Ratings

2

Specifications

PowerXL DC1 Basic Controller IP20 Standard Ratings

PowerXL DC1 Series Drives

Description

Description

Specification

2

Specification

2
2

Input Ratings

Protections
Overload protection

150% for 60s for every 600 seconds

Input voltage (Vin)

±10%

Overvoltage protection

Yes

Input frequency (fin)

50/60 Hz (variation up to 48–62 Hz)

Undervoltage protection

Yes

Connection to power

Maximum of one time every 30 seconds

Ground fault protection

Yes

Output Ratings

Overtemperature
protection

Yes

Output voltage

0 to Vin 1

2

Motor overload protection Yes

Continuous output
current

Continuous rated current IN at ambient temperature max.
122°F (50°C), 150% for 60 seconds, 175% for 2 seconds

2

Motor stall protection

Output frequency

0 to 500 Hz

Frequency resolution

0.1 Hz

2

Programmable Parameters

Initial output current (IH) 175% for 2s for every 20 seconds
Torque depends on motor

2

Description

Control Characteristics

Built-in Help card

Operation mode

2

14 Standard operation parameters

Switching frequency

4 to 32 kHz

Reference scaling

Voltage reference

10 Vdc (max. 10 mA)

Programmable start and stop functions

Field weakening point

0 to 500 Hz

DC-brake at start and stop

Acceleration time

0.1 to 600 seconds

Programmable V/Hz curve

Deceleration time

0.1 to 600 seconds

Adjustable switching frequency

Brake Resistor (Minimum Values) 2

Autorestart function after fault

230V Series

FS2 and FS3 47 ohms

Protections and supervisions

400V Series

FS2 100 ohms, FS3 47 ohms

Power section fault indication

Ambient Conditions

External fault

Ambient operating
temperature

+14°F (–10°C), no frost to +122°F (+50°C): Rated loadability IN
IP20—NEMA 0

Storage temperature

–40°F (–40°C) to +140°F (+60°C)

Relative humidity

0 to 95% RH, noncondensing, non-corrosive, no dripping water

Enclosure class

IP20 (FS1–FS3)

Yes

Fieldbus communication
Second deceleration time
Analog input range selection, signal scaling and filtering
PI controller
Skip frequencies

2

U/f control, slip compensation

2
2
2
2
2
2
2
2
2

Notes
1 Exception: 115V single-phase in, 230V three-phase out.
2 Only FS2 and FS3 drives are equipped with brake chopper circuit.

2
2
2
2
2
2
2
2
2
2

Volume 6—Solid-State Motor Control CA08100007E—May 2014 www.eaton.com

V6-T2-7

2.1

Adjustable Frequency Drives
PowerXL DC1 Series Drives

2

Standards—DC1 Series

2

I/O Specifications
●
Digital inputs DI1–DI4 are
programmable
●
Digital, relay and analog
outputs are programmable

2
2
2
2
2
2

DC1 Series I/O Interface

2

1

2
2

Terminal

Includes:
●
Four inputs (two digital and
two digital/analog)
●
Analog inputs
●
4–20 mA
●
0–10V
●
One output (analog or
digital)
●
One relay output
●
RS-485 interface

Reliability
Pretested components
●
Computerized testing
●
Final test with full load
●
Conformal-coated boards
●
Eaton’s Electrical Services &
Systems: national network
of AF drive specialists
●

Signal

Factory Preset

Description

+24 Vdc

Control voltage for DI1–DI4

—

Maximum load 100 mA
Reference potential V
8 to +30V (High, R1 > 6 kΩ)

2

DI1

Digital Input 1

Start Enable FWD

3

DI2

Digital Input 2

Start Enable REV

8 to +30V (High, R1 > 6 kΩ)

4

DI3

Digital Input 3

Fixed frequency FF1

Digital: 8–30V (high)

AI2

Analog Input 2

Fixed frequency FF1

Analog: 0 to +10V (Ri >72 kΩ)
0/4–20 mA (Rß = 500 Ω)
Can be switched with parameter P16

2
2

5

+10 Vdc

Reference voltage, Output (+10V) —

2

6

AI1

Analog Input 1

Frequency reference value 1 Analog: 0 to +10V (Ri >72 kΩ)
(fixed frequency)
0/4–20 mA (Rß = 500 Ω)
Can be switched with parameter P16

DI4

Digital Input 5

Frequency reference value 1 Digital: 8–30V (high)
(fixed frequency)

2

2

Digital Output 1

Output frequency

Digital: 8 to +24V

0V

Reference potential

—

0V connection terminal 7

10

K13

Relay 1, normally open contact

Active = RUN

Maximum switching load: 250 Vac/6A or 30 Vdc/5A

11

K14

Relay 1, normally open contact

Active = RUN

Maximum switching load: 250 Vac/6A or 30 Vdc/5A

2

4

f-Out
0 to +10V/20 mA

3

6

8
AO
(DO)

2

f-Soll
0 to +10V/20 mA

1

FF1

Note
1 Programmable function.

AI1
(DI4)

2

DO1
9

DI3
(AI2)

2

Analog: 0 to +10V, maximum 4–20 mA
Can be switched with parameter P-25

REV

2

0V = connection terminal 9

Output frequency

DI2

2

—

FWD

2

Reference potential
Analog Output 1

DI1

2

0V
AO1

24V

2

7
8

+24V Out
< 100 mA

2

Maximum load 10 mA
Reference potential 0V

CPU

2
2
2
2
2
V6-T2-8

Volume 6—Solid-State Motor Control CA08100007E—May 2014 www.eaton.com

Adjustable Frequency Drives
PowerXL DC1 Series Drives

2.1

Dimensions
Approximate Dimensions in Inches (mm)

2

DC1, Sizes FS1–FS3, Degree of Protection IP20/NEMA 0

2

Ø

2

B2

2

Ø1

2
2

Ø2

B1

2

B

2
2
2
A1

2

C1

2

C

A
Frame
Size

Ø2

Weight
lbs (kg)

A

A1

B

B1

B2

C

C1

Ø1

FS1

3.19 (81.0)

1.97 (50.0)

7.24 (184.0)

6.69 (170.0)

0.28 (7.0)

4.88 (124.0)

0.16 (4.0)

2

0.24 (6.0)

0.47 (12.0)

2.43 (1.1)

FS2

4.21 (107.0)

2.95 (75.0)

9.09 (231.0)

8.46 (215.0)

0.31 (8.0)

5.98 (152.0)

0.20 (5.0)

0.24 (6.0)

0.47 (12.0)

5.73 (2.6)

2

FS3

5.16 (131.0)

3.94 (100.0)

10.75 (273.0)

10.04 (255.0)

0.33 (8.5)

6.89 (175.0)

0.20 (5.0)

0.24 (6.0)

0.47 (12.0)

8.82 (4.0)

2
2

DC1, Sizes FS1–FS3, Degree of Protection IP66/NEMA 4

2

Ø1

2
2

Ø2

2
2

B
B1

2
2
2

B1

2
2

A1

B2

A1

C1

2

C

A
Frame
Size

Ø2

Weight
lbs (kg)

A

A1

B

B1

B2

C

C1

Ø1

FS1

6.34 (161.0)

5.85 (148.5)

9.13 (232.0)

7.44 (189.0)

0.98 (25.0)

7.24 (184.0)

0.14 (3.5)

2

0.15 (4.0)

0.31 (8.0)

5.51 (2.5)

FS2

7.40 (188.0)

6.93 (176.0)

10.12 (257.0)

7.87 (200.0)

1.12 (28.5)

7.58 (192.0)

0.14 (3.5)

0.16 (4.2)

0.33 (8.5)

10.36 (4.7)

2

FS3

8.29 (210.5)

7.78 (197.5)

12.20 (310.0)

9.90 (251.5)

1.31 (33.4)

9.21 (234.0)

0.14 (3.5)

0.16 (4.2)

0.33 (8.5)

17.42 (7.9)

Volume 6—Solid-State Motor Control CA08100007E—May 2014 www.eaton.com

V6-T2-9

2

2.1
2
2

Adjustable Frequency Drives
PowerXL DC1 Series Drives

Approximate Dimensions in Inches (mm)
DC1, Sizes FS1–FS3, Degree of Protection IP66/NEMA 4, with Local Controls
Ø1

2
2

Ø2

2
2

B

2

B1

2
2
B1

2
2
2
2
2
2
2

A1

B2

A1

C1

A

C

Frame
Size

A

A1

B

B1

B2

C

C1

Ø1

Ø2

Weight
lbs (kg)

FS1

6.34 (161.0)

5.85 (148.5)

9.13 (232.0)

7.44 (189.0)

0.98 (25.0)

7.24 (184.0)

0.14 (3.5)

0.15 (4.0)

0.31 (8.0)

6.17 (2.8)

FS2

7.40 (188.0)

6.93 (176.0)

10.12 (257.0)

7.87 (200.0)

1.12 (28.5)

7.58 (192.0)

0.14 (3.5)

0.16 (4.2)

0.33 (8.5)

11.02 (5.0)

FS3

8.29 (210.5)

7.78 (197.5)

12.20 (310.0)

9.90 (251.5)

1.31 (33.4)

9.21 (234.0)

0.14 (3.5)

0.16 (4.2)

0.33 (8.5)

18.08 (8.2)

2
2
2
2
2
2
2
2
2
2
2
2
2
2
V6-T2-10

Volume 6—Solid-State Motor Control CA08100007E—May 2014 www.eaton.com

Adjustable Frequency Drives
PowerXL DA1 Series Drives

2.2

Contents

PowerXL DA1 Series Drives

Description

Page

PowerXL DA1 Series Drives
Catalog Number Selection . . . . . . . . . . . . . . . .
Product Selection . . . . . . . . . . . . . . . . . . . . . . .
Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . .
Technical Data and Specifications . . . . . . . . . .
Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . .

V6-T2-12
V6-T2-13
V6-T2-15
V6-T2-16
V6-T2-18

2
2
2
2
2
2
2
2
2
2

Product Description

Features

Eaton’s PowerXL™ DA1
variable frequency drives are
the next generation of drives
specifically engineered for
today’s machinery
applications.

●

DA1 is the perfect match for
demanding OEM applications.
High-performance processor,
safe torque off, multiple
fieldbus protocols including
SmartWire-DT, sensorless
vector control and the
possibility to operate
permanent magnet motors
are sure to leave a lasting
impression.
Models rated at 480 volts,
three-phase, 50/60 Hz are
available in sizes ranging from
1 to 15 hp. Models rated at
240 volts, single- or threephase, 50/60 Hz are available
in sizes ranging from 0.5
to 7.5 hp. Models rated at
575 volts, three-phase,
50/60 Hz are available in sizes
ranging from 1 to 20 hp.

●

●

●
●

●

●

Compact, space-saving
design
Rugged and reliable—200%
for 4s 50°C rated
DIN rail and screw
mountable (FS1 and FS2)
Side-by-side installation
Industry-leading efficiency
delivers energy savings to
the customer
Integrated EMC filters
make the unit suitable for
commercial and industrial
networks
Communication cards that
integrate into the drive—
●
EtherNet/IP
●
DeviceNet
●
PROFIBUS-DP
●
EtherCAT
●
PROFINET
●
Modbus TCP
●
BACnet

●

●
●

●
●
●
●

●

●
●

●
●
●

Brake chopper as standard
in frames 2 and higher
Temperature-controlled fan
RS-485/Modbus® and
CANopen™ as standard
PID controller as standard
Several fieldbus options
SmartWire capability
Removable I/O terminal
blocks
Contactor style power
wiring
200% torque at zero speed
Ability to run permanent
magnet motors
PLC programming
Closed loop
Conformal coated boards

2

Standards and
Certifications

2

Product
●
Complies with EN61800-3
(2004)

2

EMC (At Default Settings)
●
EMC Category C1, C2
and C3 at default settings
(1m, 5m, 25m)

2

Safety
●
61800-5-1
●
EN 60529
●
CE
●
UL
●
cUL
●
UkrSepro
●
c-Tick
●
RoHS compliant

2
2
2

1

2
2
2
2
2

Note
1 See unit nameplate for more detailed
approvals.

2
2
2
2
2
2
2
2

Volume 6—Solid-State Motor Control CA08100007E—May 2014 www.eaton.com

V6-T2-11

2.2

Adjustable Frequency Drives
PowerXL DA1 Series Drives

2

Catalog Number Selection

2

DA1 Series Adjustable Frequency AC Drives

DA1 - 1 2 4D1 F B - A 20 C

2
2

Device Series
DA1 = Variable frequency drive, compact, Series 1
(D = Drives, A = Advanced, 1 = Series 1)

2
2

Type
C = Coated printed circuit boards

Degree of Protection
20 = IP20/NEMA 0
66 = IP66/NEMA 4
6S = IP66 with disconnect/NEMA 4

Connection in Power Section
1 = Single-phase mains connection/three-phase motor connection
3 = Three-phase mains connection/three-phase motor connection

2
2

Display Unit (Display)
A = LED display

Mains Voltage Category
2 = 230V (200–240V ±10%)
4 = 400V (380–480V ±10%)
5 = 575V (500–600V ±10%)

2

Brake Chopper
B = Brake chopper

2

Rated
Operational Current
Examples—
2D2 = 2.2A
4D1 = 4.1A
024 = 24A

2
2

EMC (Radio Interference Suppression Filter)
F = Internal RFI filter

2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
V6-T2-12

Volume 6—Solid-State Motor Control CA08100007E—May 2014 www.eaton.com

Adjustable Frequency Drives
PowerXL DA1 Series Drives

2.2

Product Selection
IP20

2

DA1 Series IP20 Enclosure Drives
hp

2

2

1

100% Continuous Frame
Current In (A)
Size 3

Catalog Number

4.3

2

DA1-124D3FB-A20C

7

2

DA1-127D0FB-A20C

10.5

2

DA1-12011FB-A20C

4.3

2

DA1-324D3FB-A20C

7

2

DA1-327D0FB-A20C

kW

Volts

1

0.75

2

1.5

200–240V single-phase in/
230V three-phase out

3

2.2

1

0.75

2

1.5

3

2.2

10.5

2

DA1-32011FB-A20C

5

4

18

3

DA1-32018FB-A20C

7.5

5.5

24

3

DA1-32024FB-A20C

1

0.75

2.2

2

DA1-342D2FB-A20C

2

1.5

4.1

2

DA1-344D1FB-A20C

3

2.2

5.8

2

DA1-345D8FB-A20C

5

4

9.5

2

DA1-349D5FB-A20C

7.5

5.5

14

3

DA1-34014FB-A20C

10

7.5

18

3

DA1-34018FB-A20C

15

11

24

3

DA1-34024FB-A20C

1

0.75

2.1

2

DA1-352D1NB-A20C

2

4.5

3.1

2

DA1-353D1NB-A20C

3

2.2

4.1

2

DA1-354D1NB-A20C

5

4

6.5

2

DA1-356D5NB-A20C

7.5

5.5

9

2

DA1-359D0NB-A20C

10

7.5

12

3

DA1-35012NB-A20C

15

11

17

3

DA1-35017NB-A20C

20

15

22

3

DA1-35022NB-A20C

200–240V three-phase in/
230V three-phase out

380–480V three-phase in/
460V three-phase out

500–600V three-phase in/
575V three-phase out

2
2
2
2
2
2
2
2
2
2
2
2
2
2
2

Notes
1 These are constant torque/high overload rated drives.
2 For all applications, select the unit such that the motor current is less than or equal to the rated continuous output current.
3 Brake chopper circuit available as standard in frames 2 and 3.

2
2
2
2
2
2
2
2
2
2
2
2
2

Volume 6—Solid-State Motor Control CA08100007E—May 2014 www.eaton.com

V6-T2-13

2.2
2

IP66

Adjustable Frequency Drives
PowerXL DA1 Series Drives

DA1 Series IP66 Enclosure Drives 1
100% Continuous Frame
Current In (A)
Size 3

Catalog Number

4.3

2

DA1-124D3FB-A6SC 4

7

2

DA1-127D0FB-A6SC 4

10.5

2

DA1-12011FB-A6SC 4

4.3

2

DA1-324D3FB-A6SC 4

7

2

DA1-327D0FB-A6SC 4

10.5

2

DA1-32011FB-A6SC 4

18

3

DA1-32018FB-A6SC 4

2.2

2

DA1-342D2FB-A6SC 4

4.1

2

DA1-344D1FB-A6SC 4

2.2

5.8

2

DA1-345D8FB-A6SC 4

5

4

9.5

2

DA1-349D5FB-A6SC 4

2

7.5

5.5

14

3

DA1-34014FB-A6SC 4

10

7.5

18

3

DA1-34018FB-A6SC 4

2

1

0.75

2.1

2

DA1-352D1NB-A6SC

2

4.5

3.1

2

DA1-353D1NB-A6SC

3

2.2

4.1

2

DA1-354D1NB-A6SC

hp 2

kW

Volts

1

0.75

2

2

1.5

200–240V single-phase in/
230V three-phase out

2

3

2.2

1

0.75

2

1.5

3

2.2

5

4

1

0.75

2

2

1.5

2

3

2

2

IP66S

2

2

200–240V three-phase in/
230V three-phase out

380–480V three-phase in/
460V three-phase out

500–600V three-phase in/
575V three-phase out

2

5

4

6.5

2

DA1-356D5NB-A6SC

7.5

5.5

9

2

DA1-359D0NB-A6SC

2

10

7.5

12

3

DA1-35012NB-A6SC

15

11

17

3

DA1-35017NB-A6SC

2

Notes
1 These are constant torque/high overload rated drives.
2 For all applications, select the unit such that the motor current is less than or equal to the rated continuous output current.
3 Brake chopper circuit available as standard in frames 2 and 3.
4 Non-disconnect version available. Substitute with -A66C.

2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
V6-T2-14

Volume 6—Solid-State Motor Control CA08100007E—May 2014 www.eaton.com

2.2

Adjustable Frequency Drives
PowerXL DA1 Series Drives

Accessories

2

DA1 Series

2

PC Communication Kit and Copy/Paste Module

Remote Keypad

Description

Catalog Number

Description

Catalog Number

Bluetooth copy/paste communication stick

DX-COM-STICK

LED remote keypad—7-segment display, IP54 rated

DX-KEY-LED 1

USB PC connection kit

DX-COM-PCKIT

OLED remote keypad—full text display, multi-line text,
multi-language, IP54

DX-KEY-OLED 1

Catalog Number

DeviceNet plug-in interface module

DX-NET-DEVICENET

PROFIBUS-DP plug-in interface module

DX-NET-PROFIBUS

EtherNet/IP plug-in interface module

DX-NET-ETHERNET-2

EtherCAT plug-in interface module

DX-NET-ETHERCAT-2

PROFINET plug-in interface module

DX-NET-PROFINET-2

Modbus TCP plug-in interface module

DX-NET-MODBUSTCP-2

BACnet plug-in interface module

DX-NET-BACNETIP-2

Extension Cables and Data Cable Splitter
Description

Catalog Number

RJ45 communication cable w/terminating resistor

DX-CBL-TERM

RS-485 data cable, RJ45, 0.5m

DX-CBL-RJ45-0M5

RS-485 data cable, RJ45, 1.0m

DX-CBL-RJ45-1M0

RS-485 data cable, RJ45, 3.0m

DX-CBL-RJ45-3M0

RS-485 three-way data cable splitter, RJ45

DX-SPL-RJ45-3SL

RS-485 data cable splitter, RJ45, (1 connector to 2 socket)

DX-SPL-RJ45-2SL1PL

SmartWire Modules

Encoder Feedback Plug-In Option Module
and Miscellaneous Cards

Description

Catalog Number
DX-NET-SWD1

Description

Catalog Number

SmartWire-DT interface for DA1 IP20

Relay output option module

DXA-EXT-3RO

Encoder feedback plug-in option module

DXA-EXT-ENCOD

Note
1 Includes 1m RS-485 data cable.

2
2

Optional Communication Modules
Description

2

2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2

Volume 6—Solid-State Motor Control CA08100007E—May 2014 www.eaton.com

V6-T2-15

2.2
2
2
2

Adjustable Frequency Drives
PowerXL DA1 Series Drives

Technical Data and Specifications
DA1 Series
Ratings

Specifications

PowerXL DA1 Basic Controller IP20 Standard Ratings

PowerXL DA1 Series Drives

2

Description

Description

2

Overload protection

150% for 60s for every 600 seconds

2

Overvoltage protection
Undervoltage protection

2
2
2
2
2
2

Specification

Protections

Specification

Input Ratings
Input voltage (Vin)

±10%

Yes

Input frequency (fin)

50/60 Hz (variation up to 48–62 Hz)

Yes

Connection to power

Maximum of one time every 30 seconds

Ground fault protection

Yes

Output Ratings

Overtemperature
protection

Yes

Output voltage

0 to Vin 1

Motor overload protection Yes

Continuous output
current

Continuous rated current IN at ambient temperature max. 122°F (50°C),
150% for 60 seconds, 200% for 4 seconds

Motor stall protection

Output frequency

0 to 500 Hz

Frequency resolution

0.1 Hz

Yes

Programmable Parameters

Initial output current (IH) 200% for 4s for every 40 seconds
Torque depends on motor

Description

Control Characteristics

Built-in Help card

Operation mode

14 Standard operation parameters

2

Reference scaling

2

DC-brake at start and stop

Programmable start and stop functions

Programmable V/Hz curve

2

Adjustable switching frequency

2

Protections and supervisions

Autorestart function after fault

U/f control, slip compensation, sensorless vector control (SLV),
vector control with feedback (CLV)

Switching frequency

4 to 32 kHz

Voltage reference

10 Vdc (max. 10 mA)

Field weakening point

0 to 500 Hz

Acceleration time

0.1 to 600 seconds

Deceleration time

0.1 to 600 seconds

Brake Resistor (Minimum Values) 2
230V Series

FS2 and FS3 15 ohms

400V Series

FS2 33 ohms, FS3 22 ohms

2

Power section fault indication

2

Fieldbus communication

Ambient operating
temperature

+14°F (–10°C), no frost to +122°F (+50°C): Rated loadability IN
IP20—NEMA 0

Safe torque off (STO) function

Storage temperature

–40°F (–40°C) to +140°F (+60°C)

Analog input range selection, signal scaling and filtering

Relative humidity

0 to 95% RH, noncondensing, non-corrosive, no dripping water

PI controller

Enclosure class

IP20 (FS1–FS3)

2
2

Ambient Conditions

External fault

Skip frequencies

2

Notes
1 Exception: 115V single-phase in, 230V three-phase out.
2 Only FS2 and FS3 drives are equipped with brake chopper circuit.

2
2
2
2
2
2
2
2
2
V6-T2-16

Volume 6—Solid-State Motor Control CA08100007E—May 2014 www.eaton.com

Adjustable Frequency Drives
PowerXL DA1 Series Drives

2.2

Standards—DA1 Series
I/O Specifications
●
Digital inputs DI1–DI5 are
programmable
●
Digital, relay and analog
outputs are programmable

Includes:
Five inputs (three digital
and two digital/analog)
●
Analog inputs
●
4–20 mA
●
0–10V
●
Two outputs (analog or
digital)
●
Two relay outputs
●
RS-485 interface
●

2

Reliability
●
Pretested components
●
Computerized testing
●
Final test with full load
●
Conformal-coated boards
●
Eaton’s Electrical Services &
Systems: national network
of AF drive specialists

2
2
2
2
2
2
2

DA1 Series I/O Interface
Terminal

Signal

Factory Preset

Description

1

+24 Vdc

Control voltage for DI1–DI5

—

Maximum load 100 mA
Reference potential V

2

DI1

Digital Input 1

Start Enable FWD 1
1

2

8 to +30V (High, R1 > 6 kΩ)

3

DI2

Digital Input 2

Start Enable REV

4

DI3

Digital Input 3

Fixed frequency FF1/FF2 1

8 to +30V (High, R1 > 6 kΩ)

5

+10 Vdc

Reference voltage, Output (+10V)

—

Maximum load 10 mA
Reference potential 0V

6

AI1

Analog Input 1

Frequency reference value 1

Analog: 0 to +10V (Ri >72 kΩ)
0/4–20 mA (Ri = 500 Ω)
Can be switched with parameter P2-30

DI4

Digital Input 5

Frequency reference value 1

Digital: 8–30V (high)

2

8 to +30V (High, R1 > 6 kΩ)

7

0V

Reference potential

—

0V = connection terminal 9

8

AO1

Analog Output 1

Output frequency

Analog: 0 to +10V, maximum 20 mA
Can be switched with parameter P2-11

DO1

Digital Output 1

Output frequency

Digital: 8–24V

9

0V

Reference potential

—

0V connection terminal 7

10

DI4

Digital Input 4

Fixed frequency FF2 1

Analog: 0 to +10V (Ri >72 kΩ)
0/4–20 mA (Ri = 500 Ω)
Can be switched with parameter P2-30

AI2

Analog Input 2

Fixed frequency FF2 1

Digital: 8–30V (high)

AO2

Analog output 2

Output current 1

Analog: 0 to +10V, maximum 4–20 mA
Can be switched with parameter P2-11

DO2

Digital output 2

Output current 1

Digital: 8–24V

12

STO+

Safe Torque Off +

—

Enable = +24V

13

STO-

Safe Torque Off –

—

11

2

2
2
2
2
2
2
2
2
2
2

Enable = 0V
1

Maximum switching load: 250 Vac/6A or 30 Vdc/5A

14

K11

Relay 1, changeover contact

Active = FAULT

15

K14

Relay 1, changeover contact (N/O)

Active = FAULT 1

Maximum switching load: 250 Vac/6A or 30 Vdc/5A

16

K12

Relay 1, changeover contact (N/C)

Active = FAULT 1

Maximum switching load: 250 Vac/6A or 30 Vdc/5A

17

K23

Relay 2, N/O contact

Active = FAULT 1

Maximum switching load: 250 Vac/6A or 30 Vdc/5A

18

K24

Relay 2, N/C contact

Active = FAULT 1

Maximum switching load: 250 Vac/6A or 30 Vdc/5A

2
2
2
2

f-Out
0 to +10V/20 mA

A-Out
0 to +10V/20 mA

6

8

11

AO1
(DO1)

2
2
2

AO2
(DO2)

f-Soll
0 to +10V/20 mA

10

AI1
(DI5)

FF2

FF1/FF2
4

DI4
(AI2)

3

DI3

REV

FWD
2

DI2

+24V Out
< 100 mA

1

DI1

+24V

Note
1 Programmable function.

2
2

CPU

Volume 6—Solid-State Motor Control CA08100007E—May 2014 www.eaton.com

V6-T2-17

2.2
2
2

Adjustable Frequency Drives
PowerXL DA1 Series Drives

Dimensions
Approximate Dimensions in Inches (mm)
DA1, Sizes FS2 and FS3, Degree of Protection IP20/NEMA 0

2

Ø

B2

2

Ø1

2
2

Ø2

2

B1

B

2
2
2
2

A1

2

C1
C

A

2

Frame
Size

A

A1

2

FS2

4.21 (107.0)

FS3

5.16 (131.0)

2

B

B1

B2

C

C1

Ø1

Ø2

Weight
lbs (kg)

2.95 (75.0)

9.09 (231.0)

8.46 (215.0)

0.31 (8.0)

7.32 (186.0)

0.20 (5.0)

0.24 (6.0)

0.47 (12.0)

3.97 (1.8)

3.94 (100.0)

10.75 (273.0)

10.04 (255.0)

0.33 (8.5)

8.03 (204.0)

0.20 (5.0)

0.24 (6.0)

0.47 (12.0)

7.72 (3.5)

DA1, Sizes FS2 and FS3, Degree of Protection IP66/NEMA 4

2

Ø1

2
2

Ø2

2
2
B

2

B1

2
2
2

B1

2
2
2
2
2

A1

B2

A1

C1

A

C

Frame
Size

A

A1

B

B1

B2

C

C1

Ø1

Ø2

Weight
lbs (kg)

FS2

7.40 (188.0)

6.93 (176.0)

10.12 (257.0)

7.87 (200.0)

0.79 (20.0)

9.42 (239.3)

0.14 (3.5)

0.16 (4.2)

0.33 (8.5)

10.4 (4.5)

FS3

8.29 (211.0)

7.78 (198.0)

12.20 (310.0)

9.90 (252.0)

0.98 (25.0)

10.48 (266.3)

0.14 (3.5)

0.16 (4.2)

0.33 (8.5)

15.9 (7.0)

2
V6-T2-18

Volume 6—Solid-State Motor Control CA08100007E—May 2014 www.eaton.com

Adjustable Frequency Drives
PowerXL DA1 Series Drives

2.2

Approximate Dimensions in Inches (mm)

2

DA1, Sizes FS2 and FS3, Degree of Protection IP66/NEMA 4, with Local Controls

2
Ø1

2
2

Ø2

2
2
2

B
B1

2
2
2
B1

2
2

A1

B2

A1

C1

A

C

Frame
Size

A

A1

B

B1

B2

C

C1

Ø1

Ø2

Weight
lbs (kg)

FS2

7.40 (188.0)

6.93 (176.0)

10.12 (257.0)

7.87 (200.0)

0.79 (20.0)

9.42 (239.3)

0.14 (3.5)

0.16 (4.2)

0.33 (8.5)

10.6 (4.8)

FS3

8.29 (211.0)

7.78 (198.0)

12.20 (310.0)

9.90 (252.0)

0.98 (25.0)

10.48 (266.3)

0.14 (3.5)

0.16 (4.2)

0.33 (8.5)

16.1 (7.3)

2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2

Volume 6—Solid-State Motor Control CA08100007E—May 2014 www.eaton.com

V6-T2-19

2.3
2

Adjustable Frequency Drives
M-Max Series Drives

M-Max Series Drives for Machinery Applications

Contents
Description

2

Page

M-Max Series Drives
Catalog Number Selection . . . . . . . . . . . . . . . .
Product Selection . . . . . . . . . . . . . . . . . . . . . . .
Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . .
Technical Data and Specifications . . . . . . . . . .
Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . .

2
2
2

V6-T2-21
V6-T2-22
V6-T2-23
V6-T2-24
V6-T2-26

2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2

Product Description
Eaton’s M-Max™ Series
Sensorless Vector Adjustable
Frequency AC Drives are
the next generation of drives
specifically engineered
for today’s machinery
applications. These microprocessor-based drives have
standard features that can be
programmed to tailor the
drive’s performance to suit a
wide variety of application
requirements. The M-Max
product line uses a 32-bit
microprocessor and insulated
gate bipolar transistors
(IGBTs) that provide quiet
motor operation, high motor
efficiency, and smooth lowspeed performance. The size
and simplicity of the M-Max
make it ideal for hassle-free
installation. Models rated at
575 volts, three-phase,
50/60 Hz are available in sizes
ranging from 1 to 7-1/2 hp.
Models rated at 480 volts,
three-phase, 50/60 Hz
are available in sizes ranging
from 1/2 to 25 hp. Models
rated at 240 volts, single- or
three-phase, 50/60 Hz are
available in sizes ranging from
1/4 to 15 hp. Models rated
at 115 volts, single-phase,
50/60 Hz are available in the
1/4 to 1-1/2 hp size range.

Features
The standard drive includes a
digital display, and operating
and programming keys on a
visually appealing, efficient
application programming
interface. The display
provides drive monitoring, as
well as adjustment and
diagnostic information. The
keys are used for digital
adjustment and programming
of the drive, as well as for
operator control. Separate
terminal blocks for control
and power wiring are
provided for customer
connections.

●

●

●

●

●
●

●

Ease of use—preset
application macros, startup
wizard, diagnostic
capabilities
Compact, space-saving
design
Rugged and reliable—
150% torque for one
minute, 50C rated,
conformal coated boards
DIN rail and screw
mountable
Side-by-side installation
Industry leading efficiency
delivers energy savings to
the customer
Integrated 5% DC choke
(FS4 and FS5)

●

●

●

●

●
●

●
●

Integrated EMC filters
make the unit suitable for
commercial and industrial
networks
IP21 as standard, option
for NEMA® 1 (FS4 and FS5)
IP20 as standard, option
for IP21 and NEMA 1
(FS1–FS3)
Brake chopper as standard
in three-phase, applications
of frames 2 (FS2) and
larger
Temperature-controlled fan
RS-485/Modbus® as
standard
PID controller as standard
Several fieldbus options

Standards and Certifications
Product
●
Complies with EN61800-3
(2004)

EMC (At Default Settings)
EMC Category C2, C3, and
C4 (Level H): With an
internal RFI filter option

●

Safety 1
●
61800-5-1
●
EN60204-1
●
CE
●
UL
●
cUL
●
IEC
●
RoHS compliant
Note
1 See unit nameplate for more detailed
approvals.

2
2
V6-T2-20

Volume 6—Solid-State Motor Control CA08100007E—May 2014 www.eaton.com

2.3

Adjustable Frequency Drives
M-Max Series Drives

Catalog Number Selection

2
MMX 1 1 AA 1D1 F 0 – 0

Description
MMX = Base catalog number

Phase
1 = Single-phase
3 = Three-phase

2
Enclosure Class
0 = NEMA 0 or IP20

Voltage
1 = 120V
4 = 480V
2 = 230V
5 = 575V

Software
Designation Series
AA

Output Current
1D6 = 1.6A
010 = 10A

2

Option
0 = Full version

2
2

EMC Filter
F = Filter
N = No filter

2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2

Volume 6—Solid-State Motor Control CA08100007E—May 2014 www.eaton.com

V6-T2-21

2.3

Adjustable Frequency Drives
M-Max Series Drives

2

Product Selection

2

M-Max

2

M-Max Basic Controller
hp 1

Volts 2

1/4

100–120V single-phase in
230V three-phase out

100% Continuous
Current IN (A)

Nominal Input
Current (A)

Frame
Size

Catalog Number

FS2

MMX11AA1D7N0-0

1.7

9.2

2.4

11.6

2

1/2
3/4

2.8

12.4

MMX11AA2D8N0-0

2

1

3.7

15

MMX11AA3D7N0-0

4.8

16.5

FS3

MMX11AA4D8N0-0

1.7

4.2

FS1

MMX12AA1D7F0-0 3

2.4

5.7

1-1/2

MMX11AA2D4N0-0

2

1/4

2

3/4

2.8

6.6

2

1

3.7

8.3

1-1/2

4.8

11.2

MMX12AA4D8F0-0 3

2

2

7

14.1

MMX12AA7D0F0-0 3

9.6

15.8

FS3

MMX12AA9D6F0-0 3

2

1/4

1.7

2.7

FS1

MMX32AA1D7N0-0

2.4

3.5

2

3/4

2.8

3.8

2

1

3.7

4.3

1-1/2

4.8

6.8

2

2

7

8.4

3

11

13.4

FS3

MMX32AA011N0-0

2

5

17

17

FS4

MMX32AA017F0-0 4

7-1/2

25

25

2

10

31

31

2

15

38

38

1/2

1.3

2.2

1.9

2.8

MMX34AA1D9F0-0 3
MMX34AA2D4F0-0 3

1/2

200–240V single-phase in
230V three-phase out

3

1/2

200–240V three-phase in
230V three-phase out

380–480V three-phase in
460V three-phase out

MMX12AA2D4F0-0 3
MMX12AA2D8F0-0 3
FS2

MMX12AA3D7F0-0 3

MMX32AA2D4N0-0
MMX32AA2D8N0-0
FS2

MMX32AA3D7N0-0
MMX32AA4D8N0-0
MMX32AA7D0N0-0

MMX32AA025F0-0 4
FS5

MMX32AA031F0-0 4
MMX32AA038F0-0 4

FS1

MMX34AA1D3F0-0 3

2

3/4
1

2.4

3.2

2

1-1/2

3.3

4

2

4.3

5.6

2

3

5.6

7.3

2

4

7.6

9.6

5

9

11.5

2

7-1/2

12

14.9

MMX34AA012F0-0 3

10

14

18.7

MMX34AA014F0-0 3

2

10

16

16

15

23

23

2

20

31

31

25

38

38

1.7

2.0

2.7

3.6

2

1
2

2
2
2

575V three-phase in
575V three-phase out

FS2

MMX34AA3D3F0-0 3
MMX34AA4D3F0-0 3
MMX34AA5D6F0-0 3

FS3

MMX34AA7D6F0-0 3
MMX34AA9D0F0-0 3

FS4

MMX34AA016F0-0 4
MMX34AA023F0-0 4

FS5

MMX34AA031F0-0 4
MMX34AA038F0-0 4

FS3

MMX35AA1D7N0-0
MMX35AA2D7N0-0

3

3.9

5.0

MMX35AA3D9N0-0

5

6.1

7.6

MMX35AA6D1N0-0

7-1/2

9.0

10.4

MMX35AA9D0N0-0

Notes
1 Horsepower ratings are based on the use of a 240V, 460V, and 575V NEMA B, four- or six-pole squirrel cage induction motor and are for reference only.
Units are to be selected such that the motor current is less than or equal to the MMX rated continuous output current.
2 For 208V, 380V, or 415V applications, select the unit such that the motor current is less than or equal to the MMX rated continuous output current.
3 Units are also available without EMC filters. Substitute -N0-0 for this option.
4 Units are also available without EMC filters and 5% DC choke. Substitute -N0-0 for this option.

2
2
2
V6-T2-22

Volume 6—Solid-State Motor Control CA08100007E—May 2014 www.eaton.com

Adjustable Frequency Drives
M-Max Series Drives

2.3

Accessories

2

M-Max Copy/Paste Module
Description

2

Catalog Number

Module is plugged onto the front of the drive to provide: upload/download of all parameters, MMX-COM-PC
direct link to a PC via USB interface for parameter assignment via MaxConnect software, and
copying of parameters for a series of devices or when exchanging devices. No PC required

2

PC Cable

2

Description

Catalog Number

Remote download USB to RJ-45 cable with software driver disk

REM-USB-DOWN

2
2
2

NEMA Type 1 Kits 1
Description

Catalog Number

NEMA Type 1 and IP21 kit for frame 1

MMX-IP21-FS1

NEMA Type 1 and IP21 kit for frame 2

MMX-IP21-FS2

NEMA Type 1 and IP21 kit for frame 3

MMX-IP21-FS3

NEMA Type 1 for frame 4

MMX-CKIT-FS4

NEMA Type 1 for frame 5

MMX-CKIT-FS5

2
2
2
2
2

Optional Communication Modules

2

Description

Catalog Number

Communication adapter kit (FS1–FS3)

MMX-NET-XA

Communication adapter kit (FS4 and FS5)

MMX-NET-XA-45

PROFIBUS DP network card with serial connection

XMX-NET-PS-A

PROFIBUS DP network card with Sub-D connection

XMX-NET-PD-A

DeviceNet network card

XMX-NET-DN-A

2
2
2
2
2

Remote Keypad

3

Description

Catalog Number

Keypad, bezel and cable

OPTRMT-BP-HMAX

Remote copy/paste keypad

MMX-REMKEY-TEXT

VFD adapter

MMX-ADAPTER-RJ45

2
2
2
2

Notes
1 NEMA Type 1 kit provides conduit entry plate.
2 Additional input and output reactors are available. Consult Eaton representative for a complete listing.
3 All three components are required for remote keypad operation.

2
2
2
2
2
2
2
2
2

Volume 6—Solid-State Motor Control CA08100007E—May 2014 www.eaton.com

V6-T2-23

2.3
2

Adjustable Frequency Drives
M-Max Series Drives

Technical Data and Specifications
Ratings

Specifications

M-Max Basic Controller IP20 Standard Ratings

M-Max Series Drives

2

Description

Description

2

Overcurrent protection

Trip limit 4.0 x IH instantaneously

Input voltage (Vin)

+10%/–15%

2

Overvoltage protection

115/230V series: 437 Vdc; 400V series: 874 Vdc;
575V series: 1048 Vdc trip level

Input frequency (fin)

50/60 Hz (variation up to 45–66 Hz)

Connection to power

Once per minute or less (typical operation)

2

Undervoltage protection

115/230V series: 183 Vdc; 400V series: 333 Vdc;
575V series: 460 Vdc trip level

Ground fault protection

Ground fault is tested before every start. In case of ground fault in
motor or motor cable, only the frequency converter is protected

Overtemperature
protection

Yes

2

2
2
2
2
2
2

Specification

Protections

Specification

Input Ratings

Output Ratings
Output voltage

0 to Vin 1

Continuous output
current

Continuous rated current IN at ambient temperature max.
122°F (50°C), overload 1.5 x IN max. 1 min/10 min

Output frequency

0 to 320 Hz

Motor overload protection Yes

Frequency resolution

0.01 Hz

Motor stall protection

Initial output current (IH) Current 2 x IN for 2 seconds in every 20-second period
Torque depends on motor

Yes

Motor underload protection Yes

Control Characteristics
Control method

Frequency control (V/Hz) open loop or sensorless vector control

Programmable Parameters

Switching frequency

1.5 to 16 kHz; default 4 kHz

Description

Frequency reference

Analog input: resolution 0.1% (10-bit), accuracy ± 1% V/Hz
Panel reference: resolution 0.01 Hz

Application macros: basic, pump, fan and high load (hoist)

2

Programmable start/stop and reverse signal logic (sinking or sourcing)

2

Programmable start and stop functions

Reference scaling

2

DC-brake at start and stop

2

Adjustable switching frequency

Field weakening point

30 to 320 Hz

Acceleration time

0 to 3000 sec

Deceleration time

0 to 3000 sec

Braking torque

DC brake: 30% x Tn (without brake option)

Brake Resistor (Minimum Values) 2

Programmable V/Hz curve

Autorestart function after fault

2

Protections and supervisions (all fully programmable; off, warning, fault)

2

External fault

230V Series

FS2 35 ohms and FS3 26 ohms, FS4 14 ohms, FS5 9 ohms

400V Series

FS2 75 ohms and FS3 54 ohms, FS4 28 ohms, FS5 17 ohms

575V Series

FS3 103 ohms

Ambient Conditions

Current signal input fault

2

Fieldbus communication

2

Analog input range selection, signal scaling and filtering

Eight preset speeds

Ambient operating
temperature

14°F (–10°C), no frost to 122°F (+50°C): Rated loadability IN

Storage temperature

–40°F (–40°C) to 158°F (70°C)

Relative humidity

0 to 95% RH, noncondensing, non-corrosive, no dripping water

Air quality

Chemical vapors: IEC 721-3-3, unit in operation, Class 3C2; Mechanical
particles: IEC 721-3-3, unit in operation, Class 3S2

Altitude

2

100% load capacity (no derating) up to 3280 ft (1000m);
1% derating for each 328 ft (100m) above 3280 ft (1000m);
max. 6560 ft (2000m)

Vibration

2

EN 60068-2-6; 3 to 150 Hz, displacement amplitude 1 mm (peak) at 3 to
15.8 Hz, max. acceleration amplitude 1G at 15.8 to 150 Hz

Shock

2

EN 50178, IEC 68-2-27 UPS Drop test (for applicable UPS weights);
storage and shipping: max. 15G, 11 ms (in package)

Enclosure class

IP20 (FS1–FS3)
IP21 (FS4 and FS5)

2

PID controller
Skip frequencies

2

Notes
1 Exception: 115V single-phase in, 230V three-phase out.
2 Only three-phase FS2 and FS3 drives are equipped with brake chopper circuit.

2
2
2
2
2
V6-T2-24

Volume 6—Solid-State Motor Control CA08100007E—May 2014 www.eaton.com

Adjustable Frequency Drives
M-Max Series Drives

2.3

Standards
I/O Specifications
●
Digital inputs DI1–DI6 are
freely programmable. The
user can assign multiple
functions to a single input
●
Digital, relay, and analog
outputs are freely
programmable

2

Reliability
●
Pretested components
●
Computerized testing
●
Final test with full load
●
Conformal-coated boards
●
Eaton’s Electrical Services &
Systems: national network
of AF drive specialists

Includes:
●
Six digital inputs
●
Two analog inputs
– 4–20 mA
– 0–10V
●
One analog output
●
One digital output
●
Two relay outputs
●
RS-485 interface

2
2
2
2
2
2
2

M-Max I/O Interface
Terminal

AUTOGEN
Ref
Current

Analog
OUT

Signal

Factory Preset

Description

1

+10V

Ref. output voltage

—

Maximum load 10 mA

2

AI1

Analog signal in 1

Freq. reference P)

0–+10V Ri = 200k ohms [min.]

3

GND

I/O signal ground

—

—

6

24V

24V output for DIs

—

±20%, max. load 50 mA

7

GND

I/O signal ground

—

—

8

DI1

Digital input 1

Start forward P)

0–+30V Ri = 12k ohms min.

9

DI2

Digital input 2

Start reverse P)

—

10

DI3

Digital input 3

Preset speed P)

—

A

A

RS-485 signal A

FB communication

—

B

B

RS-485 signal B

FB communication

—

4

AI2

Analog signal in 2

PI actual value P)

0[4]–20 mA, Ri = 200k ohms

5

GND

I/O signal ground

—

—

13

GND

I/O signal ground

—

—

14

DI4

Digital input 4

Preset speed B1 P)

0–+30V Ri = 12k ohms min.

15

DI5

Digital input 5

Fault reset P)

0–+30V Ri = 12k ohms min.

16

DI6

Digital input 6

Disable PI contr. P)

18

AO

20

DO

22

RO11

23

RO12

24

RO21

25

RO22

26

RO23

Analog output

Output frequency

Digital signal out

Active =

READY P)

P)

2
2
2
2
2
2
2
2
2
2
2

0–+30V Ri = 12k ohms min.

2

0(2)–10V, RL = 500 ohms
Open collector, max. load 48V/50 mA

Relay out 1

Active = RUN P)

Max. switching load: 250 Vac/2A or 250 Vdc/0.4A

Relay out 2

Active = FAULT P)

Max. switching load: 250 Vac/2A or 250 Vdc/0.4A

2
2
2
2

Note
P) Parameter-selectable function.

2
2
2
2
2
2
Volume 6—Solid-State Motor Control CA08100007E—May 2014 www.eaton.com

V6-T2-25

2.3
2
2

Adjustable Frequency Drives
M-Max Series Drives

Dimensions
Approximate Dimensions in Inches (mm)
Dimensions and Frame Sizes, FS1–FS3 (FS = Frame Size)

2
2

a

a

a

a1

a1

a1

2
2

2
2
2

FS1

2

FS2

2
2
FS3

2

0.28 in
(7 mm)

2

b2

2
2
2
2
2

c

2
2
2
2
2
2
2
2
V6-T2-26

Volume 6—Solid-State Motor Control CA08100007E—May 2014 www.eaton.com

b

b1

2

b

b1

b1

2

b

2

Adjustable Frequency Drives
M-Max Series Drives

2.3

Approximate Dimensions in Inches (mm)

2

Dimensions and Frame Sizes, FS4 and FS5 (FS = Frame Size)

2

a
0.28
(7.0)

a1

2

Ø

2
2
2
2
2

b2

b

b1

2
2
2
2
2
2
2
2

c

2
2

Ø1

a1

2
2

b1

Ø2

2
2
2
2
2
2
2
2
2
2
Volume 6—Solid-State Motor Control CA08100007E—May 2014 www.eaton.com

V6-T2-27

2.3
2

Adjustable Frequency Drives
M-Max Series Drives

Dimensions and Frame Sizes
Approximate Dimensions in inches (mm)
Part Number

a

a1

b

b1

b2

c

Ø, Ø1

Ø2

Installation
Size

2

MMX12AA1D7_
MMX12AA2D4_
MMX12AA2D8_

2.60
(66)

1.50
(38)

6.30
(160)

5.79
(147)

1.26
(32)

4.02
(102)

0.18
(4.5)

—

FS1

2

MMX32AA1D7_
MMX32AA2D4_
MMX32AA2D8_

3.54
(90)

2.46
(62.5)

7.68
(195)

7.17
(182)

1.26
(32)

4.14
(105)

2.17
(5.5)

—

FS2

3.94
(100)

2.95
(75)

9.96
(253)

9.53
(242)

1.34
(34)

4.41
(112)

2.17
(5.5)

—

FS3

6.50
(165.0)

5.51
(140.0)

14.57
(370.0)

13.82
(351.0)

13.27
(337.0)

6.61
(168.0)

0.28
(7.0)

0.55
(14.0)

FS4

6.50
(165.0)

5.51
(140.0)

14.57
(414.0)

13.82
(398.0)

15.08
(383.0)

8.07
(205.0)

0.28
(7.0)

0.55
(14.0)

FS5

2

2
2
2
2
2
2
2
2
2
2
2
2
2

MMX34AA1D3_
MMX34AA1D9_
MMX34AA2D4_
MMX11AA1D7_
MMX11AA2D4_
MMX11AA2D8_
MMX11AA3D7_
MMX12AA3D7_
MMX12AA4D8_
MMX12AA7D0_
MMX32AA3D7_
MMX32AA4D8_
MMX32AA7D0_
MMX34AA3D3_
MMX34AA4D3_
MMX34AA5D6_
MMX11AA4D8_
MMX12AA9D6_
MMX32AA011_
MMX34AA7D6_
MMX34AA9D0_
MMX34AA012_
MMX34AA014_
MMX35AA1D7_
MMX35AA2D7_
MMX35AA3D9_
MMX35AA6D1_
MMX35AA9D0_

2

MMX32AA012_
MMX32AA017_
MMX32AA025_

2

MMX34AA016_
MMX34AA023_

2

MMX32AA031_
MMX32AA038_

2

MMX34AA031_
MMX34AA038_

2

Note
1 in = 25.4 mm, 1 mm = 0.0394 in

2
2
2
2
2
2
2
2
V6-T2-28

Volume 6—Solid-State Motor Control CA08100007E—May 2014 www.eaton.com

Adjustable Frequency Drives
M-Max Series Drives

2.3

Approximate Dimensions in Inches (mm)

2

NEMA 1/IP21 M-Max Drives and Communication Adapter Kit

2

D

2
2

W3

2

W2

2
H

2
2
2
2
W1

Frame Type

H

W1

W2

W3

D

FS1

8.14 (206.7)

3.77 (95.7)

2.99 (75.9)

3.98 (101.2)

5.41 (137.5)

FS2

9.90 (251.5)

4.72 (120.0)

3.97 (100.8)

4.94 (125.5)

5.68 (144.2)

FS3

12.26 (311.5)

5.12 (130.1)

4.36 (110.8)

5.33 (135.3)

6.32 (160.5)

2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2

Volume 6—Solid-State Motor Control CA08100007E—May 2014 www.eaton.com

V6-T2-29

2.4
2

Adjustable Frequency Drives
PowerXL DG1 Series Drives

Contents

DG1 General Purpose Drive

Description

2

Page

PowerXL DG1 Series Drives
Standards and Certifications . . . . . . . . . . . . . .
Catalog Number Selection . . . . . . . . . . . . . . . .
Product Selection . . . . . . . . . . . . . . . . . . . . . . .
Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . .
Replacement Parts . . . . . . . . . . . . . . . . . . . . . .
Technical Data and Specifications . . . . . . . . . .
Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . .

2
2
2
2

V6-T2-31
V6-T2-31
V6-T2-32
V6-T2-34
V6-T2-38
V6-T2-40
V6-T2-44

2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2

Product Description

Features and Benefits

The DG1 general purpose
drives are part of Eaton’s next
generation PowerXL Series of
adjustable frequency drives
specifically engineered for
today’s more demanding
commercial and industrial
applications. The power unit
makes use of the most
sophisticated semiconductor
technology and a highly
modular construction that can
be flexibly adapted to meet
the customer’s needs.

Hardware
●

●

●

●

●

The control module was
designed to include today’s
standard communication
protocols and I/O while still
having the modularity to add
additional option cards.

●

●

Eaton’s patented Active
Energy Control is also a
standard feature on DG1
drives, offering customers
increased efficiency, safety
and reliability.
These drives continue
the tradition of robust
performance and raise
the bar on features and
functionality, ensuring
the best solution at the
right price.

Product Range
●
●
●

●

Brake chopper standard on
Frames 1, 2, 3
Dual overload ratings
●
110% variable torque (IL)
●
150% constant torque (IH)
Type 1/IP21 and Type 12/
IP54 enclosures available
Integrated common mode
reduction 5% DC link
choke with input surge
protection
EMI/RFI filters standard on
all drives—meets EMC
Category C2
Real-time clock—supports
calendaring and PLC
functionality
Graphic LCD display and
keypad—supports simple
menu navigation as well as
on-screen diagnostics and
troubleshooting
LOCAL/REMOTE operation
from keypad and two
configurable soft keys

Software
●

●

●

Control logic can be
powered from an external
auxiliary control panel—
internal drive functions and
fieldbus if necessary
Standard I/O:
●
8DI, 1DO
●
2AI, 2AO
●
Three relays
●
Meets needs of most
communication
requirements
Standard communications:
●
EtherNet/IP, Modbus TCP
●
RS-485: Modbus RTU,
BACnet MS/TP
●
Meets the needs of
most communication
requirements

●

●

●

●
●

●

●

Seamless integration into
EtherNet/IP networks
via EIP-Assist I/O
tag-generation tool
Two expansion slots—
intended to support
additional I/O or
communication protocols
as necessary
Quick disconnect terminals
for I/O connections—
supports fast easy
installation

230V to 125 hp, 310A, 90 kW
480V to 250 hp, 310A, 160 kW
575V to 250 hp, 250A, 160 kW

V6-T2-30

●

Volume 6—Solid-State Motor Control CA08100007E—May 2014 www.eaton.com

●

●

●

Active energy control—
minimizes energy losses
in your motor, resulting in
industry-leading energy
efficiency for your
application
Quick Start Wizard upon
initial power-up supports
fast, easy installation
Standard applications:
●
Standard
●
Multi-pump and fan
Control
●
Multi-PID
●
Multi-purpose
Copy/paste functionality
on drive keypad—allows
for fast setup of multiple
drives
Pre-programmed I/O—
supports fast, easy
installation for most
applications
Dynamic motor
regenerative energy
management
Advanced PC Tool with
diagnostic capabilities
Two configurable keypad
soft keys

Adjustable Frequency Drives
PowerXL DG1 Series Drives

2.4

Standards and Certifications
Product
●
●
●
●
●
●

EMC

IEC/EN 61800-5-1
IEC/EN 61800-5-2
UL 508C
IEC 61508
EN 62061
EN ISO 13849-1

●
●

2

Certification

Immunity: IEC/EN 61800-3
Category C2

●
●
●
●
●

2

UL
cUL
CE
C-Tick
RoHS

2
2
2
2

Catalog Number Selection

2

PowerXL Series—DG1 General Purpose Drive
Series

Power Part

Options

2

D G1 – 3 4 4D8 F B – C 21 C
Basic Naming
D = Drive

Series
G1 = General purpose

2
2

Coating of Boards
C = Coated

Phase Reference
3 = 3~ INPUT/3~ OUTPUT

Internal Brake Chopper
N = No brake chopper
B = Brake chopper

2

Enclosure (IP Rating)
21 = IP21/Type 1
54 = IP54/Type 12

2
2

Input/Output Voltage Rating
2 = 230V (208–240V, –15%, +10%)
4 = 400V (380–500V, –15%, +10%)
5 = 575V (525–600V, –15%, +10%)

Internal EMC Filter
F = Internal EMC filter

2

Display Option
C = LCD (graphical)

2
3D7 =
4D8 =
6D6 =
7D8 =
011 =
012 =
017 =
025 =
031 =
048 =
061 =
075 =
088 =
114 =
143 =
170 =
211 =
261 =

208–240V
3.7A, 0.55 kW, 0.75 hp
4.8A, 0.75 kW, 1 hp
6.6A, 1.1 kW, 1.5 hp
7.8A, 1.5 kW, 2 hp
11A, 2.2 kW, 3 hp
12.5A, 3 kW, 5 hp (VT)
17.5A, 3.7 kW, 5 hp
25A, 5.5 kW, 7.5 hp
31A, 7.5 kW, 10 hp
48A, 11 kW, 15 hp
61A, 15 kW, 20 hp
75A, 18.5 kW, 25 hp
88A, 22 kW, 30 hp
114A, 30 kW, 40 hp
143A, 37 kW, 50 hp
170A, 45 kW, 60 hp
211A, 55 kW, 75 hp
261A, 75 kW, 100 hp

Output Current Rating (CT)
380–500V
2D2 = 2.2A, 0.75 kW, 1 hp
3D3 = 3.3A, 1.1 kW, 1.5 hp
4D3 = 4.3A, 1.5 kW, 2 hp
5D6 = 5.6A, 2.2 kW, 3 hp
7D6 = 7.6A, 3 kW, 5 hp
9D0 = 9A, 4 kW, 7.5 hp (VT)
012 = 12A, 5.5 kW, 7.5 hp
016 = 16A, 7.5 kW, 10 hp
023 = 23A, 11 kW, 15 hp
031 = 31A, 15 kW, 20 hp
038 = 38A, 18 kW, 25 hp
046 = 46A, 22 kW, 30 hp
061 = 61A, 30 kW, 40 hp
072 = 72A, 37 kW, 50 hp
087 = 87A, 45 kW, 60 hp
105 = 105A, 55 kW, 75 hp
140 = 140A, 75 kW, 100 hp
170 = 170A, 90 kW, 125 hp
205 = 205A, 110 kW, 150 hp
261 = 261A, 132 kW, 200 hp

3D3 =
4D5 =
7D5 =
010 =
013 =
018 =
022 =
027 =
034 =
041 =
052 =
062 =
080 =
100 =
125 =
144 =
208 =

2

525–600V
3.3A, 1.5 kW, 2 hp
4.5A, 2.2 kW, 3 hp
7.5A, 3.7 kW, 5 hp
10A, 5.5 kW, 7.5 hp
13.5A, 7.5 kW, 10 hp
18A, 11 kW, 15 hp
22A, 15 kW, 20 hp
27A, 18 kW, 25 hp
34A, 22 kW, 30 hp
41A, 30 kW, 40 hp
52A, 37 kW, 50 hp
62A, 45 kW, 60 hp
80A, 55 kW, 75 hp
100A, 75 kW, 100 hp
125A, 90 kW, 125 hp
144A, 110 kW, 150 hp
208A, 160 kW, 200 hp

2
2
2
2
2
2
2
2
2

PowerXL Series—DG1 General Purpose Drive Option Boards

DX G – NET – PROFB
Basic Naming
DX = PowerXL Drive

Series
G = General purpose

NET =
EXT =
ACC =
SPR =
KEY =
CBL =

Type
Communication card
I/O card
Accessory
Spare part
Keypad
Cable

2
2

Function
PROFIBUS = PROFIBUS
DEVICENET = DeviceNet
LONWORKS = LonWorks
CANOPEN = CANopen
SWD = SmartWire
See Accessories on Page V6-T2-34
for full offering

Volume 6—Solid-State Motor Control CA08100007E—May 2014 www.eaton.com

2
2
2
V6-T2-31

2.4

Adjustable Frequency Drives
PowerXL DG1 Series Drives

2

Product Selection

2

DG1 Series Drives—208–240 Volt

2

PowerXL Series—DG1

Type 1/IP21
Frame Size

230V, 50 Hz
kW Rating (CT/IH)

230V, 50 Hz
kW Rating (VT/IL)

230V, 60 Hz
hp (CT/IH)

230V, 60 Hz
hp (VT/IL)

Current
A (CT/IH)

Current
A (VT/IL)

Catalog Number

FR1

0.55

0.75

0.75

1

3.7

4.8

DG1-323D7FB-C21C

2

0.75

1.1

1

1.5

4.8

6.6

DG1-324D8FB-C21C

2

1.1

1.5

1.5

2

6.6

7.8

DG1-326D6FB-C21C

1.5

2.2

2

3

7.8

11

DG1-327D8FB-C21C

2.2

3

3

—

11

12.5

DG1-32011FB-C21C

3

3.7

—

5

12.5

17.5

DG1-32012FB-C21C

3.7

5.5

5

7.5

17.5

25

DG1-32017FB-C21C

5.5

7.5

7.5

10

25

31

DG1-32025FB-C21C

7.5

11

10

15

31

48

DG1-32031FB-C21C

11

15

15

20

48

61

DG1-32048FB-C21C

15

18.5

20

25

61

75

DG1-32061FN-C21C

2

2

FR2

2
2

FR3

2

FR4

2
2

FR5

2

FR6 1

2

18.5

22

25

30

75

88

DG1-32075FN-C21C

22

30

30

40

88

114

DG1-32088FN-C21C

30

37

40

50

114

143

DG1-32114FN-C21C

37

45

50

60

143

170

DG1-32143FN-C21C

45

55

60

75

170

211

DG1-32170FN-C21C

55

75

75

100

211

261

DG1-32211FN-C21C

75

90

100

125

261

312

DG1-32261FN-C21C

2
2

PowerXL Series—DG1

2

Type 12/IP54
Frame Size

230V, 50 Hz
kW Rating (CT/IH)

230V, 50 Hz
kW Rating (VT/IL)

230V, 60 Hz
hp (CT/IH)

230V, 60 Hz
hp (VT/IL)

Current
A (CT/IH)

Current
A (VT/IL)

Catalog Number

FR1

0.55

0.75

0.75

1

3.7

4.8

DG1-323D7FB-C54C

0.75

1.1

1

1.5

4.8

6.6

DG1-324D8FB-C54C

1.1

1.5

1.5

2

6.6

7.8

DG1-326D6FB-C54C

1.5

2.2

2

3

7.8

11

DG1-327D8FB-C54C

2.2

3

3

—

11

12.5

DG1-32011FB-C54C

3

3.7

—

5

12.5

17.5

DG1-32012FB-C54C

3.7

5.5

5

7.5

17.5

25

DG1-32017FB-C54C

5.5

7.5

7.5

10

25

31

DG1-32025FB-C54C

7.5

11

10

15

31

48

DG1-32031FB-C54C

11

15

15

20

48

61

DG1-32048FB-C54C

15

18.5

20

25

61

75

DG1-32061FN-C54C

18.5

22

25

30

75

88

DG1-32075FN-C54C

22

30

30

40

88

114

DG1-32088FN-C54C

30

37

40

50

114

143

DG1-32114FN-C54C

37

45

50

60

143

170

DG1-32143FN-C54C

45

55

60

75

170

211

DG1-32170FN-C54C

55

75

75

100

211

261

DG1-32211FN-C54C

75

90

100

125

261

312

DG1-32261FN-C54C

2
2
2

FR2

2
2

FR3

2

FR4

2
FR5

2
2

FR6 1

2
2

Note
1 FR6 available in 2015.

2
2
V6-T2-32

Volume 6—Solid-State Motor Control CA08100007E—May 2014 www.eaton.com

2.4

Adjustable Frequency Drives
PowerXL DG1 Series Drives

DG1 Series Drives—380–500 Volt

2

PowerXL Series—DG1 Type 1/IP21
Frame Size

400V, 50 Hz
kW Rating (CT/IH)

400V, 50 Hz
kW Rating (VT/IL)

460V, 60 Hz
hp (CT/IH)

460V, 60 Hz
hp (VT/IL)

FR1

0.75

1.1

1

1.5

1.1

1.5

1.5

2

1.5

2.2

2

3

2.2

3

3

3

4

5

4

5.5

5.5

7.5

7.5

FR2

FR3

FR4

FR5

FR6 1

Current
A (CT/IH)

2

Current
A (VT/IL)

Catalog Number

2.2

3.3

DG1-342D2FB-C21C

3.3

4.3

DG1-343D3FB-C21C

4.3

5.6

DG1-344D3FB-C21C

5

5.6

7.6

DG1-345D6FB-C21C

—

7.6

9

DG1-347D6FB-C21C

—

7.5

9

12

DG1-349D0FB-C21C

7.5

10

12

16

DG1-34012FB-C21C

11

10

15

16

23

DG1-34016FB-C21C

11

15

15

20

23

31

DG1-34023FB-C21C

15

18.5

20

25

31

38

DG1-34031FB-C21C

18.5

22

25

30

38

46

DG1-34038FB-C21C

22

30

30

40

46

61

DG1-34046FB-C21C

30

37

40

50

61

72

DG1-34061FN-C21C

37

45

50

60

72

87

DG1-34072FN-C21C

45

55

60

75

87

105

DG1-34087FN-C21C

55

75

75

100

105

140

DG1-34105FN-C21C

75

90

100

125

140

170

DG1-34140FN-C21C

90

110

125

150

170

205

DG1-34170FN-C21C

110

132

150

200

205

261

DG1-34205FN-C21C

132

160

200

250

261

310

DG1-34261FN-C21C

2
2
2
2
2
2
2
2
2
2
2
2
2

PowerXL Series—DG1 Type 12/IP54

2

Frame Size

400V, 50 Hz
kW Rating (CT/IH)

400V, 50 Hz
kW Rating (VT/IL)

460V, 60 Hz
hp (CT/IH)

460V, 60 Hz
hp (VT/IL)

Current
A (CT/IH)

Current
A (VT/IL)

Catalog Number

FR1

0.75

1.1

1

1.5

2.2

3.3

DG1-342D2FB-C54C

1.1

1.5

1.5

2

3.3

4.3

DG1-343D3FB-C54C

1.5

2.2

2

3

4.3

5.6

DG1-344D3FB-C54C

2.2

3

3

5

5.6

7.6

DG1-345D6FB-C54C

3

4

5

—

7.6

9

DG1-347D6FB-C54C

4

5.5

—

7.5

9

12

DG1-349D0FB-C54C

5.5

7.5

7.5

10

12

16

DG1-34012FB-C54C

7.5

11

10

15

16

23

DG1-34016FB-C54C

FR2

FR3

FR4

FR5

FR6

1

11

15

15

20

23

31

DG1-34023FB-C54C

15

18.5

20

25

31

38

DG1-34031FB-C54C

18.5

22

25

30

38

46

DG1-34038FB-C54C

22

30

30

40

46

61

DG1-34046FB-C54C

30

37

40

50

61

72

DG1-34061FN-C54C

37

45

50

60

72

87

DG1-34072FN-C54C

45

55

60

75

87

105

DG1-34087FN-C54C

55

75

75

100

105

140

DG1-34105FN-C54C

75

90

100

125

140

170

DG1-34140FN-C54C

90

110

125

150

170

205

DG1-34170FN-C54C

110

132

150

200

205

261

DG1-34205FN-C54C

132

160

200

250

261

310

DG1-34261FN-C54C

2
2
2
2
2
2
2
2
2
2
2
2
2

Note
1 FR6 available in 2015.

2
Volume 6—Solid-State Motor Control CA08100007E—May 2014 www.eaton.com

V6-T2-33

2.4

Adjustable Frequency Drives
PowerXL DG1 Series Drives

2

Accessories

2

The PowerXL Series—DG1 drives can accommodate a wide
selection of expander and adapter option boards to customize
the drive for your application needs. The drive’s control unit is
designed to accept a total of two additional option boards.

PowerXL Series—DG1 Conversion and Flange Kits

The PowerXL Series—DG1 drives come with a factory-installed
standard board configuration including the following:

Type 12/IP54 Conversion Kits

2
2
2

●

2
2
2

●

Standard I/O:
●
8DI, 1DO
●
2AI, 2AO
●
Three relays
Standard communications:
●
EtherNet/IP, Modbus TCP
●
RS-485: Modbus RTU, BACnet MS/TP

Catalog Number

Frame 1 230V Type 12/IP54 kit

DXG-ACC-2FR1N12KIT

Frame 1 480V Type 12/IP54 kit

DXG-ACC-4FR1N12KIT

Frame 2 Type 12/IP54 kit

DXG-ACC-FR2N12KIT

Frame 3 Type 12/IP54 kit

DXG-ACC-FR3N12KIT

Flange Kits

PowerXL Series—DG1 I/O Card Kits
Description

Description

The flange kit is used when the power section heat sink is
mounted through the back panel of an enclosure. The kit
includes hardware, top flange plate, bottom flange plate and
two side flange plates.

2
2

The Type 12/IP54 option kit is used to convert a Type 1/IP21 to a
Type 12/IP54 drive. The kit includes cover, fan and grommets.

Catalog Number

Description

Catalog Number
DXG-ACC-FR1N12FK

2

3 x DI, 3 x DO, 1 x thermistor, 24 Vdc/EXT option card

DXG-EXT-3DI3DO1T

Frame 1 flange kit Type 12/IP54

DXG-EXT-1AI2AO

Frame 2 flange kit Type 12/IP54

DXG-ACC-FR2N12FK

2

1 x AI, 2 x AO (isolated to control board) option card
3 x relay dry contact (2NO + 1NO/NC) option card

DXG-EXT-3RO

Frame 3 flange kit Type 12/IP54

DXG-ACC-FR3N12FK

3 x PT100 RTD thermistor input option card

DXG-EXT-THER1

Frame 4 flange kit Type 12/IP54

DXG-ACC-FR4N12FK

6 x DI 240 Vac input option card

DXG-EXT-6DI

Frame 5 flange kit Type 12/IP54

DXG-ACC-FR5N12FK

2
2

PowerXL Series—DG1 Communication Card Kits

PowerXL Series—DG1 Demo Units

Description

Catalog Number

Demo Units

2

PROFIBUS-DP communication card

DXG-NET-PROFIBUS

Description

Catalog Number

2

CANopen communication card

DXG-NET-CANOPEN

DG1 control module demo stand

DG1-DEMO1

DeviceNet communication card

DXG-NET-DEVICENET

DG1 full drive demo case

DG1-DEMO2

2

PROFIBUS DB9 to 5-pin adapter card

DXG-MNT-PROFIBUS

SmartWire communication card and module

DXG-NET-SWD

2

LonWorks communication card

DXG-NET-LONWORKS

2

2

PowerXL Series—DG1 Keypad Kits

2

Description

Catalog Number

2

Standard keypad

DXG-KEY-LCD

Remote keypad kit (0.5m cable)

DXG-KEY-RMTKIT

2

1m remote keypad cable

DXG-CBL-1M0

3m remote keypad cable

DXG-CBL-3M0

2

Remote keypad mounting holder only

DXG-KEY-HOLDER

Type 12/IP54 keypad hole plug (maintain rating without keypad)

DXG-KEY-N12PLUG

2
2
2
2
2
2
V6-T2-34

Volume 6—Solid-State Motor Control CA08100007E—May 2014 www.eaton.com

Adjustable Frequency Drives
PowerXL DG1 Series Drives

2.4

PowerXpert inControl Software

2

The PowerXL Series PC Tool is designed for programming, controlling and monitoring of
the DG1 drives. Features include loading parameters that can be saved to a file or printed,
setting references, starting and stopping the motor, monitoring signals in graphical or text
form, and real-time display.

2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2

PowerXpert inControl Software
Description

Catalog Number

Software kit (software, cable, manual)

DXG-ACC-SOFTWARE

Software cable (USB to RJ45 [RS-485])

DXG-CBL-PCCABLE

Real-time clock battery

DXG-ACC-RTBATT

2
2
2

Volume 6—Solid-State Motor Control CA08100007E—May 2014 www.eaton.com

V6-T2-35

2.4
2
2
2
2
2
2
2
2
2

Adjustable Frequency Drives
PowerXL DG1 Series Drives

Brake Chopper Options
The brake chopper circuit
option is used for applications
that require dynamic braking.
Dynamic braking resistors are
not included with drive
purchase. Consult the factory
for additional dynamic braking
resistor selections that are
supplied separately. A list of
common resistors are listed
below and are complete
indoor assemblies, include a
pre-wired terminal block and
a thermal switch, and are not
UL Listed.

Duty Cycle
The duty cycle rating is based
on a 60-second period. For
example, the 20% duty cycle
resistor can carry 100%
current for 12 seconds out
of every 60 seconds, while
the 50% duty cycle resistor
can carry 150% current for
30 seconds out of every
60 seconds.

Torque
If the braking torque required
is less than 15%, dynamic
braking is not required
because the regenerated
energy will be dissipated in
the drive and motor losses.

Dynamic Brake Resistor—Catalog Number Selection

DBR – R100 – W0800

2
2

Dynamic Brake Resistor

Resistance
1D0 = 1.0 Ohms
100 = 100 Ohms

2

Rated Watts
0800 = 800 Watts
8000 = 8000 Watts
080K = 80,000 Watts

2
2

230V Brake Resistors
Drive hp
(CT/IH)

Minimum
Ohms

20% Duty Cycle, 100% Torque

50% Duty Cycle, 150% Torque

Catalog Number

Dimensions

Catalog Number

Dimensions

0.75

15.0

DBR-R100-W0400

12W x 5D x 5H

DBR-R100-W0800

12W x 7D x 5H

1

15.0

DBR-R100-W0400

12W x 5D x 5H

DBR-R100-W0800

12W x 7D x 5H

2

1.5

15.0

DBR-R100-W0400

12W x 5D x 5H

DBR-R036-W1200

12W x 10D x 5H

2

15.0

DBR-R100-W0400

12W x 5D x 5H

DBR-R036-W1200

12W x 10D x 5H

2

3

15.0

DBR-R036-W0800

12W x 7D x 5H

DBR-R036-W2000

12W x 16D x 5H

4

9.0

DBR-R036-W0800

12W x 7D x 5H

DBR-R012-W2400

19W x 10D x 5H

2

5

9.0

DBR-R036-W0800

12W x 7D x 5H

DBR-R020-W2800

19W x 13D x 5H

2

7.5

9.0

DBR-R020-W1200

12W x 10D x 5H

DBR-R012-W4800

26.5W x 10D x 5H

10

7.0

DBR-R015-W1600

12W x 13D x 5H

DBR-R112-W6000

26.5W x 13D x 5H

2

15

7.0

DBR-R012-W2400

19W x 10D x 5H

DBR-R7D8-W9000

28W x 10D x 10H

20

2.0

DBR-R9D3-W3200

19W x 10D x 5H

DBR-R3D4-W012K

28W x 10D x 10H

2

25

2.0

DBR-R5D5-W4000

26.5W x 10D x 5H

DBR-R5D1-W015K

28W x 16D x 10H

30

2.0

DBR-R4D8-W4800

26.5W x 10D x 5H

DBR-R4D1-W020K

28W x 16D x 10H

2

40

2.0

DBR-R004-W6000

26.5W x 13D x 5H

DBR-R3D4-W025K

30W x 18D x 16H

2

50

2.0

DBR-R3D1-W7500

26.5W x 16D x 5H

DBR-R2D1-W030K

30W x 18D x 24H

60

2.0

DBR-R2D8-W9000

26.5W x 16D x 5H

DBR-R002-W036K

30W x 18D x 24H

75

2.0

DBR-R2D6-W012K

28W x 10D x 10H

DBR-R002-W045K

30W x 18D x 32H

100

2.0

DBR-R002-W015K

28W x 16D x 10H

DBR-R002-W060K

30W x 18D x 48H

2
2

2
2
2
2
2
2

V6-T2-36

Volume 6—Solid-State Motor Control CA08100007E—May 2014 www.eaton.com

Adjustable Frequency Drives
PowerXL DG1 Series Drives

2.4

480V Brake Resistors
Drive hp
(CT/IH)

Minimum
Ohms

20% Duty Cycle, 100% Torque

50% Duty Cycle, 150% Torque

Catalog Number

Dimensions

Catalog Number

Dimensions

1

36.0

DBR-R100-W0400

12W x 5D x 5H

DBR-R100-W0800

12W x 7D x 5H

1.5

36.0

DBR-R100-W0400

12W x 5D x 5H

DBR-R100-W1200

12W x 10D x 5H

2

36.0

DBR-R100-W0400

12W x 5D x 5H

DBR-R100-W1200

12W x 10D x 5H

3

36.0

DBR-R100-W0800

12W x 7D x 5H

DBR-R100-W2000

12W x 16D x 5H

5

36.0

DBR-R100-W0800

12W x 7D x 5H

DBR-R100-W2800

19W x 13D x 5H

6

36.0

DBR-R100-W1200

12W x 10D x 5H

DBR-R070-W4000

19W x 16D x 5H

7.5

18.0

DBR-R100-W1200

12W x 10D x 5H

DBR-R020-W4800

26.5W x 13D x 5H

10

18.0

DBR-R063-W1600

12W x 13D x 5H

DBR-R030-W6000

26.5W x 16D x 5H

15

18.0

DBR-R030-W2400

19W x 10D x 5H

DBR-R030-W9000

28W x 10D x 10H

20

13.0

DBR-R030-W3200

19W x 13D x 5H

DBR-R023-W012K

28W x 13D x 10H

25

13.0

DBR-R030-W4000

19W x 16D x 5H

DBR-R013-W015K

28W x 16D x 10H

30

13.0

DBR-R020-W4800

26.5W x 13D x 5H

DBR-R014-W020K

30W x 18D x 24H

40

2.0

DBR-R112-W6000

26.5W x 13D x 5H

DBR-R007-W025K

30W x 18D x 16H

50

2.0

DBR-R013-W7500

26.5W x 16D x 5H

DBR-R8D5-W030K

30W x 18D x 24H

60

2.0

DBR-R010-W9000

28W x 10D x 10H

DBR-R7D3-W036K

30W x 18D x 24H

75

2.0

DBR-R009-W012K

28W x 13D x 10H

DBR-R002-W045K

30W x 18D x 32H

100

2.0

DBR-R5D1-W015K

28W x 16D x 10H

DBR-R004-W060K

30W x 18D x 40H

125

2.0

DBR-R4D1-W020K

28W x 16D x 10H

DBR-R004-W070K

30W x 18D x 48H

150

2.0

DBR-R3D4-W025K

30W x 18D x 16H

DBR-R3D5-W085K

30W x 18D x 56H

200

2.0

DBR-R3D3-W030K

30W x 18D x 24H

DBR-R2D6-W110K

30W x 18D x 64H

2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2

Volume 6—Solid-State Motor Control CA08100007E—May 2014 www.eaton.com

V6-T2-37

2.4

Adjustable Frequency Drives
PowerXL DG1 Series Drives

2

Replacement Parts

2

Frame 1

2

Description

Catalog Number
230V

Catalog Number
480V

Catalog Number
575V

Standard keypad 1

DXG-KEY-LCD

DXG-KEY-LCD

DXG-KEY-LCD

2

Main control board 1

DXG-SPR-CTRLBOARD

DXG-SPR-CTRLBOARD

DXG-SPR-CTRLBOARD

Control board cover

DXG-SPR-BCOVER

DXG-SPR-BCOVER

DXG-SPR-BCOVER

2

Type 1/IP21 standard cover

DXG-SPR-FR1CVR

DXG-SPR-FR1CVR

2

Main fan kit 1

DXG-SPR-FR1FAN

DXG-SPR-FR1FAN

2

2

Control fan

DXG-SPR-2FR1CF

DXG-SPR-4FR1CF

2

DXG-SPR-2FR1MPB

DXG-SPR-4FR1MPB

2

2

Main power board
EMI board

DXG-SPR-2FR1EB

DXG-SPR-4FR1EB

2

Middle chassis cover

DXG-SPR-FR1MCC

DXG-SPR-FR1MCC

2

Outer housing

DXG-SPR-FR1OH

DXG-SPR-FR1OH

2

UL conduit plate

DXG-SPR-FR1CPUL

DXG-SPR-FR1CPUL

2

IEC conduit plate

DXG-SPR-FR1CPIEC

DXG-SPR-FR1CPIEC

2

2
2
2

Frame 2

2

Description

Catalog Number
230V

Catalog Number
480V

Catalog Number
575V

2

Standard keypad 1

DXG-KEY-LCD

DXG-KEY-LCD

DXG-KEY-LCD

Main control board 1

DXG-SPR-CTRLBOARD

DXG-SPR-CTRLBOARD

DXG-SPR-CTRLBOARD

2

Control board cover

DXG-SPR-BCOVER

DXG-SPR-BCOVER

DXG-SPR-BCOVER

Type 1/IP21 standard cover

DXG-SPR-FR2CVR

DXG-SPR-FR2CVR

2

2

Main fan kit 1

DXG-SPR-FR2FAN

DXG-SPR-FR2FAN

2

Control fan

DXG-SPR-FR2CF

DXG-SPR-FR2CF

2

2

Bus capacitor

DXG-SPR-2FR2BC

DXG-SPR-4FR24BC

2

Main power board

DXG-SPR-2FR2MPB

DXG-SPR-4FR2MPB

2

2

EMI board

DXG-SPR-2FR2EB

DXG-SPR-4FR2EB

2

DXG-SPR-FR2IGBT

DXG-SPR-FR2IGBT

2

2

IGBT module
Middle chassis cover

DXG-SPR-FR2MCC

DXG-SPR-FR2MCC

2

Outer housing

DXG-SPR-FR2OH

DXG-SPR-FR2OH

2

UL conduit plate

DXG-SPR-FR2CPUL

DXG-SPR-FR2CPUL

2

IEC conduit plate

DXG-SPR-FR2CPIEC

DXG-SPR-FR2CPIEC

2

Description

Catalog Number
230V

Catalog Number
480V

Catalog Number
575V

Standard keypad 1

DXG-KEY-LCD

DXG-KEY-LCD

DXG-KEY-LCD

Main control board 1

DXG-SPR-CTRLBOARD

DXG-SPR-CTRLBOARD

DXG-SPR-CTRLBOARD

Control board cover

DXG-SPR-BCOVER

DXG-SPR-BCOVER

DXG-SPR-BCOVER

2
2
2
2
2

Frame 3

Type 1/IP21 standard cover

DXG-SPR-FR3CVR

DXG-SPR-FR3CVR

2

Main fan kit 1

DXG-SPR-FR3FAN

DXG-SPR-FR3FAN

2

2

Control fan

DXG-SPR-FR34CF

DXG-SPR-FR34CF

2

Bus capacitor

DXG-SPR-FR3BC

DXG-SPR-FR3BC

2

2

Main power board

DXG-SPR-2FR3MPB

DXG-SPR-4FR3MPB

2

EMI board

DXG-SPR-2FR3EB

DXG-SPR-4FR3EB

2

2

Drive board

DXG-SPR-2FR3DB

DXG-SPR-4FR3DB

2

DXG-SPR-FR3OB

DXG-SPR-FR3OB

2

2

Output board
Middle chassis cover

DXG-SPR-FR3MCC

DXG-SPR-FR3MCC

2

Outer housing

DXG-SPR-FR3OH

DXG-SPR-FR3OH

2

UL conduit plate

DXG-SPR-FR3CPUL

DXG-SPR-FR3CPUL

2

IEC conduit plate

DXG-SPR-FR3CPIEC

DXG-SPR-FR3CPIEC

2

2

2
2
2

Notes
1 Factory recommended spare parts.
2 575V available in 2015.

V6-T2-38

Volume 6—Solid-State Motor Control CA08100007E—May 2014 www.eaton.com

Adjustable Frequency Drives
PowerXL DG1 Series Drives

2.4

Frame 4
230V

480V

575V

Description

Catalog Number

Catalog Number

Catalog Number

Standard keypad 1

DXG-KEY-LCD

DXG-KEY-LCD

DXG-KEY-LCD

Main control board 1

DXG-SPR-CTRLBOARD

DXG-SPR-CTRLBOARD

DXG-SPR-CTRLBOARD

Control board cover

DXG-SPR-BCOVER

DXG-SPR-BCOVER

DXG-SPR-BCOVER

Type 1/IP21 standard cover

DXG-SPR-FR4CVR

DXG-SPR-FR4CVR

2

DXG-SPR-FR4FAN

DXG-SPR-FR4FAN

2

DXG-SPR-FR34CF

DXG-SPR-FR34CF

2

Main fan kit

1

Control fan
Bus capacitor

DXG-SPR-2FR4BC

DXG-SPR-4FR24BC

2

Main power board

DXG-SPR-2FR4MPB

DXG-SPR-4FR4MPB

2

EMI board

DXG-SPR-2FR4EB

DXG-SPR-4FR4EB

2

Softstart board

DXG-SPR-2FR4SB

DXG-SPR-4FR4SB

2

IGBT module

DXG-SPR-2FR4IGBT

DXG-SPR-4FR4IGBT

2

Rectifier module

DXG-SPR-2FR4RM

DXG-SPR-4FR4RM

2

Brake chopper module

DXG-SPR-2FR4BCM

DXG-SPR-4FR4BCM

2

Middle chassis cover

DXG-SPR-FR4MCC

DXG-SPR-FR4MCC

2

Outer housing

DXG-SPR-FR4OH

DXG-SPR-FR4OH

2

UL conduit plate

DXG-SPR-FR4CPUL

DXG-SPR-FR4CPUL

2

IEC conduit plate

DXG-SPR-FR4CPIEC

DXG-SPR-FR4CPIEC

2

230V

480V

575V

Description

Catalog Number

Catalog Number

Catalog Number

Standard keypad 1

DXG-KEY-LCD

DXG-KEY-LCD

DXG-KEY-LCD

Main control board 1

DXG-SPR-CTRLBOARD

DXG-SPR-CTRLBOARD

DXG-SPR-CTRLBOARD

Control board cover

DXG-SPR-BCOVER

DXG-SPR-BCOVER

DXG-SPR-BCOVER

Type 1/IP21 standard cover

DXG-SPR-FR5CVR

DXG-SPR-FR5CVR

2

Main fan kit 1

DXG-SPR-FR5FAN

DXG-SPR-FR5FAN

2

2
2
2
2
2
2
2
2
2
2
2
2
2

Frame 5

Control fan

DXG-SPR-FR5CF

DXG-SPR-FR5CF

2

Bus capacitor

DXG-SPR-FR5BC

DXG-SPR-FR5BC

2

Main power board

DXG-SPR-2FR5MPB

DXG-SPR-4FR5MPB

2

EMI-1 board

DXG-SPR-2FR5E1B

DXG-SPR-4FR5E1B

2

EMI-2 board

DXG-SPR-2FR5E2B

DXG-SPR-4FR5E2B

2

EMI-3 board

DXG-SPR-FR5E3B

DXG-SPR-FR5E3B

2

IGBT module

DXG-SPR-FR5IGBT

DXG-SPR-FR5IGBT

2

Rectifier module

DXG-SPR-2FR5RM

DXG-SPR-4FR5RM

2

Brake chopper module

DXG-SPR-2FR5BCM

DXG-SPR-4FR5BCM

2

Middle chassis cover

DXG-SPR-FR5MCC

DXG-SPR-FR5MCC

2

Outer housing

DXG-SPR-FR5OH

DXG-SPR-FR5OH

2

UL conduit plate

DXG-SPR-FR5CPUL

DXG-SPR-FR5CPUL

2

IEC conduit plate

DXG-SPR-FR5IECCP

DXG-SPR-FR5IECCP

2

2
2
2
2
2
2
2
2
2
2
2
2

Notes
1 Factory recommended spare parts.
2 575V available in 2015.

2
2
2
2
2
Volume 6—Solid-State Motor Control CA08100007E—May 2014 www.eaton.com

V6-T2-39

2.4

Adjustable Frequency Drives
PowerXL DG1 Series Drives

2

Technical Data and Specifications

2

PowerXL Series—DG1 Technical Data and Specifications
Attribute

Description

Specification

2

Input ratings

Input voltage Uin

208V to 240V, 380V to 500V, 525V to 600V, –15 to 10%

Input frequency

50 Hz to 60 Hz (variation up to 45 Hz to 66 Hz)

2
2
2

Output ratings

2
2
2
2

Connection to power

Once per minute or less

Starting delay

3s (FR1 to FR2), 4s (FR3), 5s (FR4), 6s (FR5)

Short-circuit withstand rating

100 kAIC

Output voltage

0 to Uin

Continuous output current

IL: ambient temperature maximum 40°C, up to 60°C with derating, overload 1.1 x IL (1 min./10 min.)
IH: ambient temperature maximum 50°C, up to 60°C with derating, overload 1.5 x IH (1 min./10 min.)

Overload current

150% respectively 110% (1 min./10 min.)

Initial output current

200% (2s/20s)

Output frequency

0–400 Hz (standard)

Frequency resolution

0.01 Hz

Control methods

Frequency control
Speed control
Open-loop speed control
Open-loop torque control

Switching frequency

2

Range:
FR1–3: 1 kHz to 12 kHz
FR4–5: 1 kHz to 10 kHz
Defaults:
FR1–3: 4 kHz (IH), 6 kHz (IL)
FR4–5: 3.6 kHz
Automatic switching frequency derating in case of overload.

Frequency reference

2

Analog input: resolution 0.1% (10-bit), accuracy +1%
Panel reference: resolution 0.01 Hz

Field weakening point

20 Hz to 400 Hz

Acceleration time

0.1s to 3000s

Deceleration time

0.1s to 3000s

Braking torque

DC brake: 30% x Motor Rated Torque (Tn) (without brake chopper)
Dynamic braking (with optional brake chopper using an external brake resistor):
100% continuous maximum rating

Ambient operating temperature

–10°C (no frost) to +50°C, up to +60°C with derating (CT)
–10°C (no frost) to +40°C, up to +60°C with derating (VT)

Storage temperature

–40°C to +70°C

2

Control characteristics

2
2
2
2

2
2
2
2

Ambient conditions

2
2
2

Relative humidity

0–95% RH, noncondensing, non-corrosive

Air quality:
Chemical vapors
Mechanical particles

Tested according to IEC 60068-2-60 Test Key:
Flowing mixed gas corrosion test, Method 1 (H2S [hydrogen sulfide] and SO2 [sulfur dioxide])
Designed according to:
IEC 60721-3-3, unit in operation, class 3C2
IEC 60721-3-3, unit in operation, class 3S2

Altitude

100% load capacity (no derating) up to 3280 ft (1000m); 1% derating for each 328 ft (100m) above
3280 ft (1000m); max. 9842 ft (3000m) (2000m for corner grounded earth main systems)

●

●

2
2
2
2
2
2
V6-T2-40

Volume 6—Solid-State Motor Control CA08100007E—May 2014 www.eaton.com

Adjustable Frequency Drives
PowerXL DG1 Series Drives

2.4

PowerXL Series—DG1 Technical Data and Specifications, continued

2

Attribute

Description

Specification

Ambient conditions,
continued

Vibration:
EN 61800-5-1
EN 60668-2-6

5–150 Hz
Displacement amplitude: 1 mm (peak) at 5 Hz to 15.8 Hz (FR1–FR5)
Maximum acceleration amplitude: 1g at 15.8 Hz to 150 Hz (FR1–FR5)

Shock:
ISTA 1 A
EN 60068-2-27

Storage and shipping: maximum 15g, 11 ms (in package)

Overvoltage

Overvoltage Category III

Pollution degree

Pollution Degree 2

2

Enclosure class

IP21/Type 1 standard in entire kW/hp range
IP54/Type 12 option
Note: Keypad required to be mounted in drive for IP54/Type 12 rating

2

Immunity

Fulfills EN 61800-3 (2004), first and second environment

MTBF

FR1: 165,457 hours
FR2: 134,833 hours
FR3: 102,515 hours
FR4: 121,567 hours
FR5: 108,189 hours
FR6: Available in 2015

●

●

2
2
2

●

2

●

Standards

2
2
2

Safety

UL 508C, CSA C22.2 No. 274-13 and EN 61800-5-1

2

EMC

+EMC2: EN 61800-3 (2004), Category C2
The drive can be modified for IT networks and corner grounding TN system

2

Electrostatic discharge

Second environment, IEC 61000-4-2, 4 kV CD or 8 kV AD, Criterion B

Fast transient burst

Second environment, IEC 61000-4-4, 2 kV/5 kHz, Criterion B

2

Dielectrical strength

Primary to secondary: 3600 Vac/5100 Vdc
Primary to earth: 2000 Vac/2828 Vdc

Approvals

EN 61800-5-1 (2007), CE, UL and cUL (see nameplate for more detailed approvals)

2
2
2

Onboard: EtherNet/IP, Modbus® TCP, Modbus RTU, BACnet

Fieldbus connections
Safety/protections

2

Overvoltage protection

Yes

Overvoltage trip limit

240V drives: 456V
480V drives: 911V

Undervoltage protection

Yes

Undervoltage trip limit

240V drives: 211V
480V drives: 370V

Earth fault protection

Yes

Input phase supervision

Yes

Motor phase supervision

Yes

Overcurrent protection

Yes

2

Unit overtemperature protection

Yes

Motor overload protection

Yes

2

2
2
2
2
2

2

Motor stall protection

Yes

Motor underload protection

Yes

DC bus overvoltage control

Yes

Short-circuit protection of 24V
reference voltages

Yes

2

Surge protection

Yes (differential mode 2 kV; common mode 4 kV)

2

Common coated boards

Yes (prevents corrosion)

2

2

2
Volume 6—Solid-State Motor Control CA08100007E—May 2014 www.eaton.com

V6-T2-41

2.4

Adjustable Frequency Drives
PowerXL DG1 Series Drives

2

Wiring Diagram

2

PowerXL Series—DG1 Control Wiring Diagram
Default Setting

Description

1

+10V

Ref. Output Voltage

—

10 Vdc Supply Source

2

AI1+

Analog Input 1

0–10V

Voltage Speed Reference (Programmable to 4 mA to 20 mA)

3

AI1–

Analog Input 1 Ground

—

Analog Input 1 Common (Ground)

4

AI2+

Analog Input 2

4 mA to 20 mA

Current Speed Reference (Programmable to 0–10V)

5

AI2–

Analog Input 2 Ground

—

Analog Input 2 Common (Ground)

2

6

GND

I/O Signal Ground

—

I/O Ground for Reference and Control

2

7

DIN5

Digital Input 5

Preset Speed B0

Sets frequency output to Preset Speed 1

8

DIN6

Digital Input 6

Preset Speed B1

Sets frequency output to Preset Speed 2

2

9

DIN7

Digital Input 7

Emergency Stop (TI–)

Input forces VFD output to shut off

10

DIN8

Digital Input 8

Force Remote (TI+)

Input takes VFD from Local to Remote

11

CMB

DI5 to DI8 Common

Grounded

Allows source input

2

12

GND

I/O Signal Ground

—

I/O Ground for Reference and Control

13

24V

+24 Vdc Output

—

Control voltage output (100 mA max.)

2

14

DO1

Digital Output 1

Ready

Shows the drive is ready to run

2

15

24Vo

+24 Vdc Output

—

Control voltage output (100 mA max.)

16

GND

I/O Signal Ground

—

I/O Ground for Reference and Control

17

AO1+

Analog Output 1

Output Frequency

Shows Output frequency to motor 0–60 Hz (4 mA to 20 mA)

18

AO2+

Analog Output 2

Motor Current

Shows Motor current of motor 0–FLA (4 mA to 20 mA)

2
2

Res

Signal Name Signal

2

Pin

i

2

2
2

19

24Vi

+24 Vdc Input

—

External control voltage input

2

20

DIN1

Digital Input 1

Run Forward

Input starts drive in forward direction (start enable)

21

DIN2

Digital Input 2

Run Reverse

Input starts drive in reverse direction (start enable)

2

22

DIN3

Digital Input 3

External Fault

Input causes drive to fault

2

23

DIN4

Digital Input 4

Fault Reset

Input resets active faults

24

CMA

DI1 to DI4 Common

Grounded

Allows source input

2

25

A

RS-485 Signal A

—

Fieldbus Communication (Modbus, BACnet)

26

B

RS-485 Signal B

—

Fieldbus Communication (Modbus, BACnet)

2

27

R3NO

Relay 3 Normally Open

At Speed

Relay output 3 shows VFD is at Ref. Frequency

2

28

R1NC

Relay 1 Normally Closed

Run

Relay output 1 shows VFD is in a run state

29

R1CM

Relay 1 Common

30

R1NO

Relay 1 Normally Open

31

R3CM

Relay 3 Common

At Speed

Relay output 3 shows VFD is at Ref. Frequency

32

R2NC

Relay 2 Normally Closed

Fault

Relay output 2 shows VFD is in a fault state

33

R2CM

Relay 2 Common

34

R2NO

Relay 2 Normally Open

2
2
2
2
2
2
2
2
2
2
V6-T2-42

Volume 6—Solid-State Motor Control CA08100007E—May 2014 www.eaton.com

Adjustable Frequency Drives
PowerXL DG1 Series Drives

2.4

Control Board Layout

2

PowerXL Series—DG1 Control Board Layout

2
2
2

Fan Power Wire

Connect DSP Part
to Power Board

2

Keypad

2

STO

2
2
2

1

AI Mode Selection

Connect MCU Part
to Power Board
2 3

ON

2
Battery (Standard)

2

RJ45 EtherNet/IP,
Modbus TCP

2

Optional Card A

2

Optional Card B

Control I/O
Terminals

2

ON

1

RS-485 Terminating
Resistor

2

Removable
MOV Screw

2
2

Removable
EMC Screw

2

Line Ground
Clamp Location

2

Motor Ground
Clamp Location

2

Line Ground
Clamp Location
Grounding
Strap Location

Grounding
Strap Location

2
2

Line Side

2

Motor

2
2
2
2
2
2
2
Volume 6—Solid-State Motor Control CA08100007E—May 2014 www.eaton.com

V6-T2-43

2.4
2
2

Adjustable Frequency Drives
PowerXL DG1 Series Drives

Dimensions
Approximate Dimensions in Inches (mm)
PowerXL Series—DG1 Dimensions

2

W4

D

2
2

W2

2
2
2

H1

H2

H3

2
2
2

W1

2
2
2
2

W3
Frame
Size
FR1

2
2

FR2

2
2
2

FR3

FR4

2
2

FR5

2
2
2
2

FR6 1

Voltage

hp (CT/IH) kW

Amperes
(CT/IH)

Approximate Dimensions in Inches (mm)
D

H1

H2

H3

W1

W2

W3

W4

Ø

Weight
Lb (kg)

7.89
(200.4)

12.87
(326.9)

12.28
(311.9)

11.50
(292.1)

6.02
(153.0)

4.80
(121.9)

3.94
(100.1)

3.94
(100.1)

0.28
(7.0)

14.33
(6.5)

9.63
(244.7)

16.50
(419.1)

15.98
(405.9)

14.96
(380.0)

6.61
(167.8)

5.28
(134.1)

3.54
(90.0)

3.54
(90.0)

0.28
(7.0)

23.37
(10.6)

10.44
(265.1)

21.97
(558.0)

21.46
(545.0)

20.43
(518.9)

8.06
(204.6)

7.24
(183.9)

4.92
(125.0)

4.92
(125.0)

0.35
(9.0)

49.82
(22.6)

11.57
(294.0)

24.80
(629.9)

34.31
(617.5)

23.27
(591.1)

9.36
(237.7)

9.13
(231.9)

8.07
(205.0)

8.07
(205.0)

0.35
(9.0)

77.60
(35.2)

13.41
(340.7)

34.98
(888.5)

29.65
(753.1)

27.83
(706.9)

11.34
(288.0)

11.10
(281.9)

8.66
(220.0)

8.66
(220.0)

0.35
(9.0)

154.32
(70.0)

1

1

1

1

1

1

1

1

1

1

230 Vac

0.75–3

0.55–2.2

3.5–11

480 Vac

1–5

0.75–3.7

2.3–7.6

575 Vac 1

2–5

1.5–3.7

3.3–7.5

230 Vac

5–7.5

3–5.5

12.5–25

480 Vac

7.5–15

5.5–11

12–23

575 Vac 1

7.5–15

5.5–11

10–18

230 Vac

10–15

7.5–11

31–48

480 Vac

20–30

15–22

31–46

575 Vac 1

20–30

15–22

22–34

230 Vac

20–30

15–22

61–88

480 Vac

40–60

30–45

61–87

575 Vac 1

40–60

30–45

41–62

230 Vac

40–60

30–45

114–170

480 Vac

75–125

55–90

105–170

575 Vac 1

75–125

55–90

80–125

230 Vac

75–100

55–75

211–261

480 Vac

150–200

110–150

205–261

575 Vac 1

150–200

110–160

144–208

Note
1 FR6 and 575 Vac available in 2015.

2
2
2
2
V6-T2-44

Volume 6—Solid-State Motor Control CA08100007E—May 2014 www.eaton.com

Adjustable Frequency Drives
SVX9000 Drives

2.5

Contents

SVX9000 Drives

Description

Page

SVX9000 Drives
SVX9000 Drives . . . . . . . . . . . . . . . . . . . . . . . .
SVX9000 Enclosed Drives . . . . . . . . . . . . . . . .
SVX9000 VFD Pump Panels . . . . . . . . . . . . . . .

V6-T2-48
V6-T2-87
V6-T2-111

2
2
2
2
2
2
2
2
2
2

Product Overview

Application Description

With the SVX9000 Series
Sensorless Vector Control,
Eaton’s expanded Eaton drive
offering now covers a
complete line of PWM
adjustable frequency (speed)
drives in ratings from:

Application Engineering

●

●

●

●

208V—3/4 to 100 hp IH;
1 to 100 hp IL
230V—3/4 to 100 hp IH;
1 to 125 hp IL
480V—1 to 1900 hp IH;
1-1/2 to 2200 hp IL
575V—2 to 2000 hp IH;
3 to 2300 hp IL

The Eaton family of drives
includes DA1, DC1, H-Max,
M-Max, SVX9000 and
SPX9000. 9000X Series drive
ratings are rated for either
high overload (IH) or low
overload (IL). IL indicates
110% overload capacity for
1 minute out of 10 minutes.
IH indicates 150% overload
capacity for 1 minute out of
10 minutes.
A full range of enclosure
types and options are
available to meet a wide array
of applications—from simple
variable torque to more
complex industrial
applications such as
conveyors, mixers and
machine controls.

Proper selection and
application of all drive system
components is essential to
assure that an adjustable
frequency drive system will
safely and reliably provide the
performance required for any
given application. The party
responsible for the overall
design and operation of the
facility must make sure that
qualified personnel are
employed to select all
components of the drive
system, including appropriate
safety devices. Eaton’s AF
Drives Application
Engineering Department is
prepared to provide
assistance to answer any
questions about the technical
capabilities of Eaton drives.
Motor Selection
The basic requirement of
motor selection is to match
the torque vs. speed
capability of the motor to the
torque vs. speed requirement
of the driven load.

2
Motor Torque vs. Speed
Capability
As the speed of a motor is
reduced below its 60 Hz base
speed, motor cooling
becomes less effective
because of the reduced speed
of the self-cooling fan. This
limitation determines the
maximum torque for
continuous operation at any
operating speed. The
maximum intermittent
operating torque is
determined by the motor’s
torque vs. current
characteristics and the output
current capability of the
adjustable frequency
controller.

2
Special Types of Motors
Standard NEMA Designs A
and B three-phase motors are
the only motors
recommended for use in the
majority of applications, but
other types of motors are
occasionally used. If the
existing motor used in the
application or the motor
proposed for use with the
drive system is a type other
than NEMA Design A or B,
Application Engineering
assistance must be
requested to make certain
that the drive is properly
applied.

2
2
2
2
2
2
2
2
2
2

Multiple Motor Operation
A number of motors can be
connected in parallel to a
single controller. Since the
frequency of the power
supplied by the controller is
the same for each motor, the
motors will always operate at
the same speed. Application
Engineering assistance must
be requested for all multiple
motor applications to assure
compliance with all controller
design limitations.

2
2
2
2
2
2
2
2

Volume 6—Solid-State Motor Control CA08100007E—May 2014 www.eaton.com

V6-T2-45

2.5
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2

Adjustable Frequency Drives
SVX9000 Drives

Product Selection Guide

Features

Controller Selection

Controller Features

The basic requirement of
controller selection is to
match the output current,
voltage and frequency
capabilities of the controller
with the requirements of the
connected motor.

Operator Control and Interface
Requirements
Since there are many
possible configurations and
many ways of achieving a
specific end result, it pays to
consider the operator control
and interface requirements
carefully. A simplified and
more economical drive
package can often be
achieved by selecting from
standard product offerings
rather than specifying a
custom designed
configuration.

Output Current
The controller must be
selected and applied such
that the average operating
motor current and
horsepower do not exceed
the continuous current and
horsepower ratings of the
controller. The intermittent
operating current must not
exceed the intermittent
current rating of the
controller.
Motor Protection
Eaton adjustable frequency
drives include electronic
motor overload protection
circuits that are designed to
meet the requirements of
NEC article 430-2 provided
that only one motor is
connected to the output of
the controller.
Output Voltage and Frequency
When they are shipped, AF
controllers are adjusted to
provide a maximum output
voltage and frequency
equivalent to the input line
voltage and frequency. The
controllers can be adjusted to
operate above line frequency,
but a hazard of personal injury
or equipment damage may
exist when the motor is
operated above base speed.
Before adjusting the drive to
operate above line frequency,
make sure that the motor and
the driven machinery can
safely be operated at the
resulting speed.

Installation Compatibility
The successful application
of an AC drive requires the
assurance that the drive will
be compatible with the
environment in which it will
be installed. In planning the
installation, be sure to
carefully consider the heat
produced by the drive, the
altitude and temperature
limits and the need for clean
cooling air. Other important
considerations include
acoustical noise, vibration,
electromagnetic compatibility,
power quality, controller input
harmonic current and power
distribution equipment
requirements.

Auxiliary Equipment and
Accessories
Adjustable drives are
generally designed to have a
motor directly connected to
the controller output
terminals with no other
equipment connected in
series or parallel. Motor
starters, disconnect
switches, surge absorbers,
DV/DT suppression circuits,
output chokes, output
transformers and any other
equipment under
consideration for installation
on the output of the controller
should not be installed
without first requesting
Application Engineering
assistance. Power factor
correction capacitors must
never, under any
circumstances, be connected
at the output of the controller.
They would serve no useful
purpose, and they may
damage the controller.

2
2
2
2
2
V6-T2-46

Volume 6—Solid-State Motor Control CA08100007E—May 2014 www.eaton.com

Enclosure Definitions
●
NEMA Type 1/IP21—
Enclosures are intended for
indoor use primarily to
provide a degree of
protection against contact
with enclosed equipment
and provide a degree of
protection against a limited
amount of falling dirt in
locations where unusual
service conditions do not
exist. Top or side openings
in the NEMA Type 1/IP21
enclosure allow for the free
exchange of inside and
outside air while meeting
the UL rod entry and rust
resistance design tests.
●

NEMA Type 12/IP54—
Enclosures are intended
for indoor use primarily to
provide a degree of
protection against
circulating dust, falling dirt
and dripping noncorrosive
liquids. To meet UL drip,
dust and rust resistance
tests, NEMA Type 12/IP54
enclosures have no
openings to allow for the
exchange of inside and
outside air.

●

Chassis IP00—Similar to
Protected Chassis IP20
except power terminals are
protected by plastic
shielding only. Primarily
intended to be mounted
inside a surrounding
protective enclosure.

●

NEMA Type 3R—Similar in
design to NEMA Type 12/
IP54 except with more
stringent design and test
requirements.

Adjustable Frequency Drives
SVX9000 Drives

2.5

Motor Protection

2

DV/DT and Peak Motor Voltage Solutions
Today’s AFD products offer
significantly improved
performance, but at the
potential cost of motor
insulation stress. The fast
switching time of the IGBT
devices used in newer AFDs
can cause a transmission line
effect in the output power
leads to the motor, leading to
possibly damaging voltage
levels. To meet this need,

2

NEMA has introduced a
motor in MG1, Part 31, which
provides an insulation system
designed to maintain normal
motor life in AFD applications.
For existing motors, a motor
protection scheme is required
for longer cable runs. Eaton
offers three standard solutions
for existing systems.
●

●

2
2
2
2
2

MotoRx This solution
provides an energy
recovery system which
clamps the peak motor
voltage to a safe level
for standard motors. This
option is used when the
distance between a single
motor and the drive is
600 ft or less.
Output Line Reactor This
option provides an output
line reactor, reducing the
DV/DT of the AFD output
voltage and lessening the
transmission line effect, to
lower the peak voltage at
the motor terminals.

2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2

Volume 6—Solid-State Motor Control CA08100007E—May 2014 www.eaton.com

V6-T2-47

2.5
2

Adjustable Frequency Drives
SVX9000 Drives

Contents

SVX9000 Drives

Description

2

Page

SVX9000 Drives
Standards and Certifications . . . . . . . . . . . . . .
Catalog Number Selection . . . . . . . . . . . . . . . .
Product Selection . . . . . . . . . . . . . . . . . . . . . . .
Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . .
Options . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Replacement Parts . . . . . . . . . . . . . . . . . . . . . .
Technical Data and Specifications . . . . . . . . . .
Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . .
SVX9000 Enclosed Drives . . . . . . . . . . . . . . . . . . .
SVX9000 VFD Pump Panels . . . . . . . . . . . . . . . . .

2
2
2
2
2

V6-T2-49
V6-T2-49
V6-T2-50
V6-T2-54
V6-T2-55
V6-T2-61
V6-T2-70
V6-T2-71
V6-T2-87
V6-T2-111

2
2
2
2

SVX9000 Drives

2

Product Description

Features

SVX9000 Series Adjustable
Frequency Drives from
Eaton’s Electrical Sector are
the next generation of drives
specifically engineered for
today’s commercial and
industrial applications. The
power unit makes use of the
most sophisticated
semiconductor technology
and a highly modular
construction that can be
flexibly adapted to the
customer’s needs.

●

2
2
2
2
2
2
2
2
2
2
2
2
2
2
2

The input and output
configuration (I/O) is designed
with modularity in mind. The
I/O is compromised of option
cards, each with its own input
and output configuration. The
control module is designed to
accept a total of five of these
cards. The cards contain not
only normal analog and digital
inputs but also fieldbus cards.
These drives continue the
tradition of robust
performance, and raise the
bar on features and
functionality, ensuring the
best solution at the right
price.

●

●

●

●

●

●

●

●

Robust design—proven
500,000 hours MTBF
Integrated 3% line reactors
standard on drives from
FR4 through FR9
EMI/RFI Filters H standard
up to 200 hp IH 480V, 100
hp IH 230V
Simplified operating menu
allows for typical
programming changes,
while programming mode
provides control of
everything
Quick Start Wizard built
into the programming of
the drive ensures a smooth
start-up
Keypad can display up to
three monitored
parameters simultaneously
LOCAL/REMOTE operation
from keypad
Copy/paste function allows
transfer of parameter
settings from one drive to
the next
Standard NEMA Type 12/
IP54 keypad on all drives

●

●

●

The SVX can be flexibly
adapted to a variety of
needs using our preinstalled “Seven in One”
precision application
programs consisting of:
●
Basic
●
Standard
●
Local/remote
●
Multi step speed control
●
PID control
●
Multi-purpose control
●
Pump and fan control
with auto change
Additional I/O and
communication cards
provide plug and play
functionality
I/O connections with
simple quick connection
terminals

2
2
2
V6-T2-48

Volume 6—Solid-State Motor Control CA08100007E—May 2014 www.eaton.com

●

●

●

●

●

●

Hand-held auxiliary 24V
power supply allows
programming/monitoring
of control module without
applying full power to the
drive
Control logic can be
powered from an external
auxiliary control panel,
internal drive functions and
fieldbus if necessary
Brake chopper standard
from: 1–30 hp/380–500V
3/4–15 hp/208–230V
NEMA Type 1/IP21 and
NEMA Type 12/IP54
enclosures available,
Frame Sizes FR4–FR9
Open chassis FR10 and
greater
Standard option board
configuration includes an
A9 I/O board and an A2
relay output board installed
in slots A and B

Adjustable Frequency Drives
SVX9000 Drives

2.5

Standards and Certifications
EMC (At Default Settings)
●
Immunity: Fulfills all EMC
immunity requirements;
Emissions: EN 61800-3,
LEVEL H

Product
●
IEC 61800-2

2

Safety
●
UL 508C
●
CE

2
2
2
2

Catalog Number Selection

2

SVX9000 Adjustable Frequency Drives

SVX 010 A 1 – 4 A 1 B 1
Product Family
SVX = Open drives
SPX = Open drives FR10 and greater

Board Modifications
1 = Standard boards
2 = Conformal (varnished) coating 4

Horsepower Rating
F07 = 3/4 hp
800 = 800 hp
F15 = 1-1/2 hp
900 = 900 hp
007 = 7-1/2 hp
H10 = 1000 hp
010 = 10 hp
H12 = 1200 hp
050 = 50 hp
H13 = 1350 hp
125 = 125 hp
H15 = 1500 hp
350 = 350 hp
H16 = 1600 hp
700 = 700 hp
H20 = 2000 hp

Brake Chopper Options 2
N = No brake chopper circuit
B = Internal brake chopper circuit

AFD Software Series
A = Standard software

Keypad
A = Alphanumeric

Input Options 1
1 = Three-phase, EMC H
2 = Three-phase, EMC N
4 = Three-phase, EMC L

Enclosure 3
0 = Chassis
1 = NEMA Type 1/IP21
2 = NEMA Type 12/IP54

2

_ _ _ _ _ _

Voltage Rating
2 = 230V (208–240)
4 = 480V (380–500)
5 = 575V (525–690)

2

Options
Options appear in alphabetical order.
Extended I/O Card Options
B1 = 6 DI, 1 ext +24 Vdc/EXT +24 Vdc
B2 = 1 RO (NC-NO), 1 RO (NO), 1 therm
B4 = 1 AI (mA isolated), 2 AO (mA isolated),
1 ext +24 Vdc/EXT + 24 Vdc
B5 = 3 RO (NO)
B8 = 1 ext +24 Vdc/EXT +24 Vdc, 3 Pt100
B9 = 1 RO (NO), 5 DI 42–240 Vac input
Communication Cards
CA = Johnson Controls N2
CI = Modbus TCP
CJ = BACnet
CQ = EtherNet/IP
C2 = Modbus
C3 = PROFIBUS DP
C4 = LonWorks
C5 = PROFIBUS DP (D9 connector)
C6 = CANopen (slave)
C7 = DeviceNet
C8 = Modbus (D9 Type connector)
D3 = RS-232 with D9 connection

Notes
1 All 230V drives and 480V drives up to 200 hp (IH) are only available with input option 1 (EMC Level H). 480V drives 250 hp (IH) or larger are available
with input option 2 (EMC Level N). 480V drives are available with input option 4 (EMC Level L). 575V drives 200 hp (IH) or larger are only available
with input option 2. 575V drives up to 150 hp (IH) are only available with input option 4 (EMC Level L).
2 480V drives up to 30 hp (IH) are only available with brake chopper option B. 480V drives 40 hp (IH) or larger come standard with brake chopper option
N. 230V drives up to 15 hp (IH) are only available with brake chopper option B. 230V drives 20 hp or larger come standard with brake chopper option
N. All 575V drives come standard without brake chopper option (N). N = No brake chopper.
3 480V drives 250 hp (I ) and larger are available with enclosure style 0 (chassis); 690V drives 200 hp (I ) and larger are available with
H
H
enclosure style 0 (chassis).
4 Factory promise delivery. Consult sales office for availability.

2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2

Volume 6—Solid-State Motor Control CA08100007E—May 2014 www.eaton.com

V6-T2-49

2.5

Adjustable Frequency Drives
SVX9000 Drives

2

Product Selection

2

230V SVX9000 Drives

2

SVX9000 Open Drives

208–240V, NEMA Type 1/IP21 Drives
Frame
Size

2

FR4

2
2
2

FR5

2
2

FR6

2

FR7

2
FR8

2
2

FR9

2
2

hp (IH)

Current (IH)

hp (IL)

Current (IL)

Catalog Number

3/4

3.7

1

4.8

SVXF07A1-2A1B1

1

4.8

1-1/2

6.6

SVX001A1-2A1B1

1-1/2

6.6

2

7.8

SVXF15A1-2A1B1

2

7.8

3

11

SVX002A1-2A1B1

3

11

—

12.5

SVX003A1-2A1B1

—

12.5

5

17.5

SVX004A1-2A1B1

5

17.5

7-1/2

25

SVX005A1-2A1B1

7-1/2

25

10

31

SVX007A1-2A1B1

10

31

15

48

SVX010A1-2A1B1

15

48

20

61

SVX015A1-2A1B1

20

61

25

75

SVX020A1-2A1N1

25

75

30

88

SVX025A1-2A1N1

30

88

40

114

SVX030A1-2A1N1

40

114

50

140

SVX040A1-2A1N1

50

140

60

170

SVX050A1-2A1N1

60

170

75

205

SVX060A1-2A1N1

75

205

100

261

SVX075A1-2A1N1

100

261

125

300

SVX100A1-2A1N1

208–240V, NEMA Type 12/IP54 Drives

2

Frame
Size

hp (IH)

Current (IH)

hp (IL)

Current (IL)

Catalog Number

FR4

3/4

3.7

1

4.8

SVXF07A2-2A1B1

2

1

4.8

1-1/2

6.6

SVX001A2-2A1B1

1-1/2

6.6

2

7.8

SVXF15A2-2A1B1

2

2

7.8

3

11

SVX002A2-2A1B1

3

11

—

12.5

SVX003A2-2A1B1

—

12.5

5

17.5

SVX004A2-2A1B1

5

17.5

7-1/2

25

SVX005A2-2A1B1

7-1/2

25

10

31

SVX007A2-2A1B1

10

31

15

48

SVX010A2-2A1B1

15

48

20

61

SVX015A2-2A1B1

2

2

FR5

2
2

FR6

2

FR7

2
FR8

2
2

FR9

2

20

61

25

75

SVX020A2-2A1N1

25

75

30

88

SVX025A2-2A1N1

30

88

40

114

SVX030A2-2A1N1

40

114

50

140

SVX040A2-2A1N1

50

140

60

170

SVX050A2-2A1N1

60

170

75

205

SVX060A2-2A1N1

75

205

100

261

SVX075A2-2A1N1

100

261

125

300

SVX100A2-2A1N1

2
2
2
V6-T2-50

Volume 6—Solid-State Motor Control CA08100007E—May 2014 www.eaton.com

Adjustable Frequency Drives
SVX9000 Drives

2.5

480V SVX9000 Drives
SVX9000 Open Drives

2
380–500V, NEMA Type 1/IP21 Drives

2

Frame
Size

hp (IH)

Current (IH)

hp (IL)

Current (IL)

Catalog Number

FR4

1

2.2

1-1/2

3.3

SVX001A1-4A1B1

1-1/2

3.3

2

4.3

SVXF15A1-4A1B1

2

4.3

3

5.6

SVX002A1-4A1B1

3

5.6

5

7.6

SVX003A1-4A1B1

5

7.6

—

9

SVX005A1-4A1B1

—

9

7-1/2

12

SVX006A1-4A1B1

7-1/2

12

10

16

SVX007A1-4A1B1

10

16

15

23

SVX010A1-4A1B1

15

23

20

31

SVX015A1-4A1B1

20

31

25

38

SVX020A1-4A1B1

25

38

30

46

SVX025A1-4A1B1

30

46

40

61

SVX030A1-4A1B1

FR5

FR6

FR7

FR8

FR9

40

61

50

72

SVX040A1-4A1N1

50

72

60

87

SVX050A1-4A1N1

60

87

75

105

SVX060A1-4A1N1

75

105

100

140

SVX075A1-4A1N1

100

140

125

170

SVX100A1-4A1N1

125

170

150

205

SVX125A1-4A1N1

150

205

200

261

SVX150A1-4A1N1

200

245

250

300

SVX200A1-4A1N1

2
2
2
2
2
2
2
2
2
2
2
2
2

380–500V, NEMA Type 12/IP54 Drives

2

Frame
Size

hp (IH)

Current (IH)

hp (IL)

Current (IL)

Catalog Number

FR4

1

2.2

1-1/2

3.3

SVX001A2-4A1B1

1-1/2

3.3

2

4.3

SVXF15A2-4A1B1

2

4.3

3

5.6

SVX002A2-4A1B1

3

5.6

5

7.6

SVX003A2-4A1B1

5

7.6

—

9

SVX005A2-4A1B1

—

9

7-1/2

12

SVX006A2-4A1B1

7-1/2

12

10

16

SVX007A2-4A1B1

10

16

15

23

SVX010A2-4A1B1

15

23

20

31

SVX015A2-4A1B1

20

31

25

38

SVX020A2-4A1B1

25

38

30

46

SVX025A2-4A1B1

30

46

40

61

SVX030A2-4A1B1

40

61

50

72

SVX040A2-4A1N1

50

72

60

87

SVX050A2-4A1N1

60

87

75

105

SVX060A2-4A1N1

75

105

100

140

SVX075A2-4A1N1

100

140

125

170

SVX100A2-4A1N1

125

170

150

205

SVX125A2-4A1N1

150

205

200

261

SVX150A2-4A1N1

200

245

250

300

SVX200A2-4A1N1

FR5

FR6

FR7

FR8

FR9

2
2
2
2
2
2
2
2
2
2
2
2
2
2

Volume 6—Solid-State Motor Control CA08100007E—May 2014 www.eaton.com

V6-T2-51

2.5
2

Adjustable Frequency Drives
SVX9000 Drives

380–500V, Open Chassis Drives

SVX9000 Open Drives

Frame
Size

2

FR10

1

2
2

FR11

2
2

FR12

2

FR13

2
2

FR14

2

hp (IH)

Current (IH)

hp (IL)

Current (IL)

Catalog Number

250

330

300

385

SPX250A0-4A2N1

300

385

350

460

SPX300A0-4A2N1

350

460

400

520

SPX350A0-4A2N1

400

520

500

590

SPX400A0-4A2N1

500

590

—

650

SPX500A0-4A2N1

—

650

600

730

SPX550A0-4A2N1

600

730

—

820

SPX600A0-4A2N1

—

820

700

920

SPX650A0-4A2N1

700

920

800

1030

SPX700A0-4A2N1

800

1030

900

1150

SPX800A0-4A2N1

900

1150

1000

1300

SPX900A0-4A2N1

1000

1300

1200

1450

SPXH10A0-4A2N1

1200

1600

1500

1770

SPXH12A0-4A2N1

1600

1940

1800

2150

SPXH16A0-4A2N1

1900

2300

2200

2700

SPXH19A0-4A2N1

2
2

575V SVX9000 Drives

2

525–690V, NEMA Type 1/IP21 Drives
Frame
Size

hp (IH)

Current (IH)

hp (IL)

Current (IL)

Catalog Number

FR6

2

3.3

3

4.5

SVX002A1-5A4N1

3

4.5

—

5.5

SVX003A1-5A4N1

2

—

5.5

5

7.5

SVX004A1-5A4N1

5

7.5

7-1/2

10

SVX005A1-5A4N1

2

7-1/2

10

10

13.5

SVX007A1-5A4N1

10

13.5

15

18

SVX010A1-5A4N1

2

15

18

20

22

SVX015A1-5A4N1

2

20

22

25

27

SVX020A1-5A4N1

25

27

30

34

SVX025A1-5A4N1

30

34

40

41

SVX030A1-5A4N1

40

41

50

52

SVX040A1-5A4N1

50

52

60

62

SVX050A1-5A4N1

60

62

75

80

SVX060A1-5A4N1

75

80

100

100

SVX075A1-5A4N1

100

100

125

125

SVX100A1-5A4N1

125

125

150

144

SVX125A1-5A4N1

150

144

—

170

SVX150A1-5A4N1

—

170

200

208

SVX175A1-5A4N1

2
2

2

FR7

2

FR8

2

FR9

2
2
2

Note
1 FR10–FR14 includes 3% line reactor, but it is not integral to chassis.

2
2
2
2
2
V6-T2-52

Volume 6—Solid-State Motor Control CA08100007E—May 2014 www.eaton.com

Adjustable Frequency Drives
SVX9000 Drives

SVX9000 Open Drives

2.5

525–690V, NEMA Type 12/IP54 Drives

2

Frame
Size

hp (IH)

Current (IH)

hp (IL)

Current (IL)

Catalog Number

FR6

2

3.3

3

4.5

SVX002A2-5A4N1

3

4.5

—

5.5

SVX003A2-5A4N1

—

5.5

5

7.5

SVX004A2-5A4N1

5

7.5

7-1/2

10

SVX005A2-5A4N1

7-1/2

10

10

13.5

SVX007A2-5A4N1

10

13.5

15

18

SVX010A2-5A4N1

15

18

20

22

SVX015A2-5A4N1

20

22

25

27

SVX020A2-5A4N1

25

27

30

34

SVX025A2-5A4N1

30

34

40

41

SVX030A2-5A4N1

40

41

50

52

SVX040A2-5A4N1

50

52

60

62

SVX050A2-5A4N1

60

62

75

80

SVX060A2-5A4N1

FR7

FR8

FR9

75

80

100

100

SVX075A2-5A4N1

100

100

125

125

SVX100A2-5A4N1

125

125

150

144

SVX125A2-5A4N1

150

144

—

170

SVX150A2-5A4N1

—

170

200

208

SVX175A2-5A4N1

2
2
2
2
2
2
2
2
2
2
2
2

525–690V, Open Chassis Drives
Frame
Size
FR10

FR11

FR12

FR13

FR14

hp (IH)

Current (IH)

2
hp (IL)

Current (IL)

Catalog Number

200

208

250

261

SPX200A0-5A2N1

250

261

300

325

SPX250A0-5A2N1

300

325

400

385

SPX300A0-5A2N1

400

385

450

460

SPX400A0-5A2N1

450

460

500

502

SPX450A0-5A2N1

500

502

—

590

SPX500A0-5A2N1

—

590

600

650

SPX550A0-5A2N1

600

650

700

750

SPX600A0-5A2N1

700

750

800

820

SPX700A0-5A2N1

800

820

900

920

SPX800A0-5A2N1

900

920

1000

1030

SPX900A0-5A2N1

1000

1030

1250

1180

SPXH10A0-5A2N1

1350

1300

1500

1500

SPXH13A0-5A2N1

1500

1500

2000

1900

SPXH15A0-5A2N1

2000

1900

2300

2250

SPXH20A0-5A2N1

2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2

Volume 6—Solid-State Motor Control CA08100007E—May 2014 www.eaton.com

V6-T2-53

2.5

Adjustable Frequency Drives
SVX9000 Drives

2

Accessories

2

Demo Drive and Power Supply

2
2
2
2
2
2
2
2
2

Demo Drive and Power Supply
Description

Catalog Number

9000X demo drive

9000XDEMO

NEMA Type 12/IP54 Conversion Kit
The NEMA Type 12/IP54 kit
option is used to convert a
NEMA Type 1/IP21 to a
NEMA Type 12/IP54 drive.
The NEMA Type 12/IP54

kit consists of a metal
drive shroud, fan kit for
some frames, adaptor plate
and plugs.

NEMA Type 12/IP54 Conversion Kit
Approximate Dimensions in Inches (mm)
Frame Size

Delivery Code

Length

Width

Height

Approximate
Weight Lb (kg)

Catalog Number

FR4

W

13 (330)

7 (178)

4 (102)

4 (1.8)

OPTN12FR4

FR5

16 (406)

8 (203)

7 (178)

5 (2.3)

OPTN12FR5

FR6

21 (533)

10 (254)

5 (127)

7 (3.2)

OPTN12FR6

2
2
2
2
2
2
2

Flange Kits
Flange Kit NEMA Type 12/
IP54
The flange kit is utilized when
the power section is mounted
through the back panel of an
enclosure. Includes flange
mount brackets and NEMA
Type 12/IP54 fan
components. Metal shroud
not included.

Flange kits for NEMA Type
12/IP54 enclosure drive rating
are determined by rating of
drive.

Flange Kit NEMA Type 12/
IP54—Frames 4–9
Frame
Size

Delivery
Code

Catalog
Number

Flange Kit NEMA Type 12/
IP54— Frames 4, 5 and 6 1

FR4

FP

OPTTHR4

FR5

OPTTHR5

Frame
Size

FR6

OPTTHR6

FR7

OPTTHR7

FR8

OPTTHR8

FR9

OPTTHR9

FR4

2

Delivery
Code
W

Catalog
Number
OPTTHRFR4

FR5

OPTTHRFR5

FR6

OPTTHRFR6

2
2
2

Note
1 For installation of an SVX9000 NEMA Type 1/IP21 drive into a NEMA Type 12/IP54 oversized enclosure.

2
2
2
2
2
2
2
2
V6-T2-54

Volume 6—Solid-State Motor Control CA08100007E—May 2014 www.eaton.com

2.5

Adjustable Frequency Drives
SVX9000 Drives

Options

2

9000X Series Option Board Kits

2

The 9000X Series drives can accommodate a wide selection of expander and adapter option boards
to customize the drive for your application needs. The drive’s control unit is designed to accept a
total of five option boards.
The 9000X Series factory installed standard board configuration includes an A9 I/O board and an A2
relay output board, which are installed in slots A and B.
Option Boards

2
2

Option Board Kits

2

Allowed Slot
Locations 2

Field
Installed
Catalog
Number

Factory
Installed
Option
Designator

SVX Ready Programs
Local/
Basic Remote Standard

MSS

PID

Multi-P. PFC

6 DI, 1 DO, 2 AI, 1AO, 1 +10 Vdc ref,
2 ext +24 Vdc/EXT +24 Vdc

A

OPTA9

—

■

■

■

■

■

■

■

2 RO (NC-NO)

B

OPTA2

—

■

■

■

■

■

■

■

2 RO, therm—SPX only

B

OPTA3

A3

—

■

■

■

■

■

■

Encoder low volt +5V/15V/24V—SPX only

C

OPTA4

A4

—

■

■

■

■

■

■

Encoder high volt +15V/24V—SPX only

C

OPTA5

A5

—

■

■

■

■

■

■

Double encoder—SPX only

C

OPTA7

A7

■

■

■

■

■

■

■

6 DI, 1 DO, 2 AI, 1 AO—SPX only

A

OPTA8

A8

—

■

■

■

■

■

■

3 DI (encoder 10–24V), out +15V/+24V,
2 DO (pulse+direction)—SPX only

C

OPTAE

AE

■

■

■

■

■

■

■

2

6 DI, 1 ext +24 Vdc/EXT +24 Vdc

B, C, D, E

OPTB1

B1

—

—

—

—

—

■

■

2

1 RO (NC-NO), 1 RO (NO), 1 therm

B, C, D, E

OPTB2

B2

—

—

—

—

—

■

■

1 AI (mA isolated), 2 AO (mA isolated),
1 ext +24 Vdc/EXT +24 Vdc

B, C, D, E

OPTB4

B4

■

■

■

■

■

■

■

2

3 RO (NO)

B, C, D, E

OPTB5

B5

—

—

—

—

—

■

■

2

1 ext +24 Vdc/EXT +24 Vdc, 3 Pt100

B, C, D, E

OPTB8

B8

—

—

—

—

—

—

—

1 RO (NO), 5 DI 42–240 Vac input

B, C, D, E

OPTB9

B9

—

—

—

—

—

■

■

2

Modbus 3

D, E

OPTC2

C2

■

■

■

■

■

■

■

2

Johnson Controls N2 3

D, E

OPTC2

CA

—

—

—

—

—

—

—

Modbus TCP

D, E

OPTCI

CI

■

■

■

■

■

■

■

Option Kit Description 1
Standard I/O Cards
A

D E
B C

Extended I/O Cards

Communication Cards

BACnet

D, E

OPTCJ

CJ

■

■

■

■

■

■

■

EtherNet/IP

D, E

OPTCQ

CQ

■

■

■

■

■

■

■

PROFIBUS DP

D, E

OPTC3

C3

■

■

■

■

■

■

■

LonWorks

D, E

OPTC4

C4

■

■

■

■

■

■

■

PROFIBUS DP (D9 connector)

D, E

OPTC5

C5

■

■

■

■

■

■

■

CANopen (slave) 4

D, E

OPTC6

C6

■

■

■

■

■

■

■

DeviceNet

D, E

OPTC7

C7

■

■

■

■

■

■

■

Modbus (D9 type connector)

D, E

OPTC8

C8

■

■

■

■

■

■

■

Adapter—SPX only

D, E

OPTD1

D1

■

■

■

■

■

■

■

Adapter—SPX only

D, E

OPTD2

D2

■

■

■

■

■

■

■

RS-232 with D9 connection

D, E

OPTD3

D3

■

■

■

■

■

■

■

2
2
2
2
2
2

2
2
2
2
2
2
2
2

Notes
1 AI = Analog Input; AO = Analog Output, DI = Digital Input, DO = Digital Output, RO = Relay Output
2 Option card must be installed in one of the slots listed for that card. Slot indicated in bold is the preferred location.
3 OPTC2 is a multi-protocol option card.
4 SPX9000 drives only (FR10 and larger).

2
2
2
2
2

Volume 6—Solid-State Motor Control CA08100007E—May 2014 www.eaton.com

V6-T2-55

2.5
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2

Adjustable Frequency Drives
SVX9000 Drives

Modbus RTU Network
Communications
The Modbus Network Card
OPTC2 is used for connecting
the 9000X Drive as a slave on
a Modbus network. The
interface is connected by a
9-pin DSUB connector
(female) and the baud rate
ranges from 300 to 19200
baud. Other communication
parameters include an
address range from 1 to 247;
a parity of None, Odd or
Even; and the stop bit is 1.

DeviceNet Network
Communications
The DeviceNet Network Card
OPTC7 is used for connecting
the 9000X Drive on a
DeviceNet Network. It
includes a 5.08 mm pluggable
connector. Transfer method
is via CAN using a two-wire
twisted shielded cable with
two-wire bus power cable
and drain. The baud rates
used for communication
include 125K baud, 250K
baud and 500K baud.

PROFIBUS Network
Communications
The PROFIBUS Network Card
OPTC3 is used for connecting
the 9000X Drive as a slave
on a PROFIBUS-DP network.
The interface is connected
by a 9-pin DSUB connector
(female). The baud rates
range from 9.6K baud to 12M
baud, and the addresses
range from 1 to 127.

Johnson Controls
Metasys N2 Network
Communications
The OPTC2 fieldbus board
provides communication
between the 9000X Drive and
a Johnson Controls
Metasys™ N2 network. With
this connection, the drive can
be controlled, monitored and
programmed from the
Metasys system. The N2
fieldbus is available as a
factory installed option and as
a field installable kit.

LonWorks Network
Communications
The LonWorks Network Card
OPTC4 is used for connecting
the 9000X Drive on a
LonWorks network. This
interface uses Standard
Network Variable Types
(SNVT) as data types. The
channel connection is
achieved using a FTT-10A
Free Topology transceiver
via a single twisted transfer
cable. The communication
speed with LonWorks is
78 kBits/s.
CANopen (Slave)
Communications
The CANopen (Slave)
Network Card OPTC6 is used
for connecting the 9000X
Drive to a host system.
According to ISO11898
standard cables to be chosen
for CAN bus should have a
nominal impedance of 120
ohms, and specific line delay
of nominal 5 nS/m. 120 ohms
line termination resistors
required for installation.

Modbus/TCP Network
Communications
The Modbus/TCP Network
Card OPTCI is used for
connecting the 9000X Drive
to Ethernet networks utilizing
Modbus protocol. It includes
an RJ-45 pluggable connector.
This interface provides a
selection of standard and
custom register values to
communicate drive parameters.
The board supports 10 Mbps
and 100 Mbps communication
speeds. The IP address of the
board is configurable over
Ethernet using a supplied
software tool.

BACnet Network
Communications
The BACnet Network Card
OPTCJ is used for connecting
the 9000X Drive to BACnet
networks. It includes a
5.08 mm pluggable connector.
Data transfer is Master-Slave/
Token Passing (MS/TP)
RS-485. This interface uses
a collection of 30 Binary Value
Objects (BVOs) and 35 Analog
Value Objects (AVOs) to
communicate drive parameters.
The card supports 9.6, 19.2
and 38.4 Kbaud communication
speeds and supports network
addresses 1–127.
EtherNet/IP Network
Communications
The EtherNet/IP Network
Card OPTCK is used for
connecting the 9000X Drive
to Ethernet/Industrial Protocol
networks. It includes an
RJ-45 pluggable connector.
The interface uses CIP
objects to communicate drive
parameters (CIP is “Common
Industrial Protocol”, the same
protocol used by DeviceNet).
The board supports 10 Mbps
and 100 Mbps communication
speeds. The IP address of the
board is configurable by Static,
BOOTP and DHCP methods.

2
2
2
V6-T2-56

Volume 6—Solid-State Motor Control CA08100007E—May 2014 www.eaton.com

Adjustable Frequency Drives
SVX9000 Drives

2.5

Control Panel Options

2

Factory Options

2

Factory Installed

Field Installed

Option Code

NEMA Type 1/IP21
Catalog Number

2

Local/Remote Keypad SVX9000 Control Panel—This option is standard on all drives and
A
consists of an RS-232 connection, backlit alphanumeric LCD display with nine indicators for the
RUN status and two indicators for the control source. The nine pushbuttons on the panel are used
for panel programming and monitoring of all SVX9000 parameters. The panel is detachable and
isolated from the input line potential. Include LOC/REM key to choose control location.

KEYPAD-LOC/REM

2

Keypad Remote Mounting Kit—This option is used to remote mount the SVX9000 keypad. The
footprint is compatible to the SV9000 remote mount kit. Includes 10 ft cable, keypad holder and
mounting hardware.

OPTRMT-KIT-9000X

Description

—

2
2
2
2

Miscellaneous Options
Description

Catalog Number

9000XDrive—A PC-based tool for controlling and monitoring of the SVX9000. Features include: loading parameters that
can be saved to a file or printed, setting references, starting and stopping the motor, monitoring signals in graphical or text
form, and real-time display. To avoid damage to the drive or computer, SVDrivecable must be used.

9000XDRIVE

SVDrivecable—6 ft (1.8m) RS-232 cable (22 gauge) with a 7-pin connector on each end. Should be used in conjunction
with the 9000XDrive option to avoid damage to the SVX9000 or computer. The same cable can be used for downloading
specialized applications to the drive.

SVDRIVECABLE

External Dynamic Braking Resistors—Used with the dynamic braking chopper circuit to absorb motor regenerative
energy for stopping the load and to dissipate the energy flowing back into the drive. Resistors are separated into standard
duty and heavy-duty. Standard duty is defined as 20% duty or less with 100% braking torque, while heavy-duty is defined as
50% duty or less with 150% braking torque.

See Page V6-T2-58

2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2

Volume 6—Solid-State Motor Control CA08100007E—May 2014 www.eaton.com

V6-T2-57

2.5
2
2
2
2
2
2
2
2

Adjustable Frequency Drives
SVX9000 Drives

Open Drive Options
Brake Chopper Options
The brake chopper circuit
option is used for applications
that require dynamic braking.
Dynamic braking resistors are
not included with drive
purchase. Consult the factory
for additional dynamic braking
resistor selections that are
supplied separately. A list of
common resistors are listed
below and are complete
indoor assemblies, include a
pre-wired terminal block and
a thermal switch, and are not
UL Listed.

Duty Cycle
The duty cycle rating is based
on a 60-second period. For
example, the 20% duty cycle
resistor can carry 100%
current for 12 seconds out
of every 60 seconds, while
the 50% duty cycle resistor
can carry 150% current for
30 seconds out of every
60 seconds.

Torque
If the braking torque required
is less than 15%, dynamic
braking is not required
because the regenerated
energy will be dissipated in
the drive and motor losses.

2
2

Dynamic Brake Resistor—Catalog Number Selection

DBR – R100 – W0800

2
2

Dynamic Brake Resistor

Resistance
1D0 = 1.0 Ohms
100 = 100 Ohms

2

Rated Watts
0800 = 800 Watts
8000 = 8000 Watts
080K = 80,000 Watts

2

230V Brake Resistors

2

Drive hp
(CT/IH)

Minimum
Ohms

20% Duty Cycle, 100% Torque

50% Duty Cycle, 150% Torque

Catalog Number

Dimensions (Inches)

Catalog Number

Dimensions (Inches)

2

0.75

30.0

DBR-R100-W0400

12W x 5D x 5H

DBR-R100-W0800

12W x 7D x 5H

1

30.0

DBR-R100-W0400

12W x 5D x 5H

DBR-R100-W0800

12W x 7D x 5H

1.5

30.0

DBR-R100-W0400

12W x 5D x 5H

DBR-R036-W1200

12W x 10D x 5H

2

2

30.0

DBR-R100-W0400

12W x 5D x 5H

DBR-R036-W1200

12W x 10D x 5H

3

30.0

DBR-R036-W0800

12W x 7D x 5H

DBR-R036-W2000

12W x 16D x 5H

2

4

30.0

DBR-R036-W0800

12W x 7D x 5H

DBR-R030-W2400

19W x 10D x 5H

5

30.0

DBR-R036-W0800

12W x 7D x 5H

DBR-R030-W2800

19W x 13D x 5H

2

7.5

20.0

DBR-R020-W1200

12W x 10D x 5H

DBR-R020-W4800

26.5W x 13D x 5H

2

10

10.0

DBR-R015-W1600

12W x 13D x 5H

DBR-R112-W6000

26.5W x 13D x 5H

15

10.0

DBR-R012-W2400

19W x 10D x 5H

DBR-R010-W9000

28W x 10D x 10H

2

20

3.3

DBR-R9D3-W3200

19W x 10D x 5H

DBR-R3D4-W012K

28W x 10D x 10H

25

3.3

DBR-R5D5-W4000

26.5W x 10D x 5H

DBR-R5D1-W015K

28W x 16D x 10H

2

30

3.3

DBR-R4D8-W4800

26.5W x 10D x 5H

DBR-R4D1-W020K

28W x 16D x 10H

40

1.4

DBR-R004-W6000

26.5W x 13D x 5H

DBR-R3D4-W025K

30W x 18D x 16H

2

50

1.4

DBR-R3D1-W7500

26.5W x 16D x 5H

DBR-R2D1-W030K

30W x 18D x 24H

2

60

1.4

DBR-R2D8-W9000

26.5W x 16D x 5H

DBR-R002-W036K

30W x 18D x 24H

75

1.4

DBR-R2D6-W012K

28W x 10D x 10H

DBR-R1D5-W045K

30W x 18D x 32H

100

1.4

DBR-R002-W015K

28W x 16D x 10H

DBR-R1D4-W060K

30W x 18D x 40H

2

2
2
2
2
2

V6-T2-58

Volume 6—Solid-State Motor Control CA08100007E—May 2014 www.eaton.com

Adjustable Frequency Drives
SVX9000 Drives

2.5

480V Brake Resistors
Drive hp
(CT/IH)

Minimum
Ohms

20% Duty Cycle, 100% Torque

50% Duty Cycle, 150% Torque

Catalog Number

Dimensions (Inches)

Catalog Number

Dimensions (Inches)

1

63.0

DBR-R100-W0400

12W x 5D x 5H

DBR-R100-W0800

12W x 7D x 5H

1.5

63.0

DBR-R100-W0400

12W x 5D x 5H

DBR-R100-W1200

12W x 10D x 5H

2

63.0

DBR-R100-W0400

12W x 5D x 5H

DBR-R100-W1200

12W x 10D x 5H

3

63.0

DBR-R100-W0800

12W x 7D x 5H

DBR-R100-W2000

12W x 16D x 5H

5

63.0

DBR-R100-W0800

12W x 7D x 5H

DBR-R100-W2800

19W x 13D x 5H

6

63.0

DBR-R100-W1200

12W x 10D x 5H

DBR-R070-W4000

19W x 16D x 5H

7.5

63.0

DBR-R100-W1200

12W x 10D x 5H

DBR-R063-W4800

26.5W x 13D x 5H

10

63.0

DBR-R063-W1600

12W x 13D x 5H

DBR-R063-W6000

26.5W x 16D x 5H

15

42.0

DBR-R042-W2400

19W x 10D x 5H

DBR-R042-W9000

28W x 10D x 10H

20

21.0

DBR-R030-W3200

19W x 13D x 5H

DBR-R023-W012K

28W x 13D x 10H

25

21.0

DBR-R030-W4000

19W x 16D x 5H

DBR-R021-W015K

28W x 13D x 10H

30

14.0

DBR-R020-W4800

26.5W x 13D x 5H

DBR-R014-W020K

30W x 18D x 24H

40

6.5

DBR-R112-W6000

26.5W x 13D x 5H

DBR-R007-W025K

30W x 18D x 16H

50

6.5

DBR-R013-W7500

26.5W x 16D x 5H

DBR-R8D5-W030K

30W x 18D x 24H

60

6.5

DBR-R010-W9000

28W x 10D x 10H

DBR-R7D3-W036K

30W x 18D x 24H

75

3.3

DBR-R009-W012K

28W x 13D x 10H

DBR-R3D3-W045K

30W x 18D x 32H

100

3.3

DBR-R5D1-W015K

28W x 16D x 10H

DBR-R004-W060K

30W x 18D x 40H

125

3.3

DBR-R4D1-W020K

28W x 16D x 10H

DBR-R004-W070K

30W x 18D x 48H

150

3.3

DBR-R3D4-W025K

30W x 18D x 16H

DBR-R3D5-W085K

30W x 18D x 56H

200

3.3

DBR-R3D3-W030K

30W x 18D x 24H

DBR-R3D3-W110K

30W x 18D x 72H

250

1.4

DBR-R2D5-W036K

30W x 18D x 24H

1

—

300

1.4

DBR-R1D5-W045K

30W x 18D x 32H

1

—

350

1.4

DBR-R1D4-W060K

30W x 18D x 40H

1

—

400

0.9

DBR-R1D4-W060K

30W x 18D x 40H

1

—

500

0.9

DBR-R0D9-W080K

30W x 18D x 48H

1

—

550

0.9

DBR-R001-W085K

30W x 18D x 56H

1

—

2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2

Note
1 Consult factory.

2
2
2
2
2
2
2
2
2
2
2
2
2
Volume 6—Solid-State Motor Control CA08100007E—May 2014 www.eaton.com

V6-T2-59

2.5
2

Adjustable Frequency Drives
SVX9000 Drives

575V Brake Resistors
Drive hp
(CT/IH)

Minimum
Ohms

20% Duty Cycle, 100% Torque

50% Duty Cycle, 150% Torque

Catalog Number

Dimensions (Inches)

Catalog Number

Dimensions (Inches)

2

100.0

DBR-R100-W0400

12W x 5D x 5H

DBR-R100-W1200

12W x 10D x 5H

3

100.0

DBR-R100-W0800

12W x 7D x 5H

DBR-R100-W2000

12W x 16D x 5H

2

4

100.0

DBR-R100-W0800

12W x 7D x 5H

DBR-R100-W2400

19W x 10D x 5H

5

100.0

DBR-R100-W0800

12W x 7D x 5H

DBR-R100-W2800

19W x 13D x 5H

2

7.5

100.0

DBR-R100-W1200

12W x 10D x 5H

DBR-R100-W4800

26.5W x 13D x 5H

10

30.0

DBR-R063-W1600

12W x 13D x 5H

DBR-R063-W6000

26.5W x 16D x 5H

2

15

30.0

DBR-R042-W2400

19W x 10D x 5H

DBR-R042-W9000

28W x 10D x 10H

2

20

30.0

DBR-R030-W3200

19W x 13D x 5H

DBR-R030-W012K

28W x 13D x 10H

25

30.0

DBR-R030-W4000

19W x 16D x 5H

DBR-R030-W015K

28W x 16D x 10H

2

30

18.0

DBR-R020-W4800

26.5W x 13D x 5H

DBR-R020-W020K

30W x 18D x 16H

40

18.0

DBR-R030-W6000

26.5W x 16D x 5H

DBR-R184-W025K

30W x 18D x 16H

2

50

9.0

DBR-R013-W7500

26.5W x 16D x 5H

DBR-R012-W030K

30W x 18D x 24H

60

9.0

DBR-R010-W9000

28W x 10D x 10H

DBR-R010-W036K

30W x 18D x 24H

2

75

9.0

DBR-R009-W012K

28W x 13D x 10H

DBR-R009-W045K

30W x 18D x 24H

2

100

7.0

DBR-R013-W015K

28W x 16D x 10H

DBR-R8D4-W060K

30W x 18D x 40H

125

7.0

DBR-R8D2-W020K

30W x 18D x 10H

DBR-R007-W070K

30W x 18D x 40H

2

150

7.0

DBR-R007-W025K

30W x 18D x 16H

DBR-R006-W085K

30W x 18D x 56H

175

7.0

DBR-R007-W030K

30W x 18D x 24H

DBR-R007-W100K

30W x 18D x 72H

2

200

2.5

DBR-R3D3-W030K

30W x 18D x 24H

DBR-R2D6-W110K

30W x 18D x 64H

250

2.5

DBR-R2D5-W036K

30W x 18D x 24H

DBR-R003-W140K

30W x 18D x 72H

2

300

2.5

DBR-R3D3-W045K

30W x 18D x 32H

1

—

2

400

1.7

DBR-R002-W060K

30W x 18D x 48H

1

—

450

1.7

DBR-R1D8-W070K

30W x 18D x 48H

1

—

2

500

1.7

DBR-R002-W080K

30W x 18D x 56H

1

—

2
2

2

Note
1 Consult factory.

2
2
2
2
2
2
2
2
2
2
2
2
2
V6-T2-60

Volume 6—Solid-State Motor Control CA08100007E—May 2014 www.eaton.com

Adjustable Frequency Drives
SVX9000 Drives

2.5

Replacement Parts

2

FR4 Spare Parts
Category

Description
1

Quantity/
Drive

230V

480V

575V

Catalog Number

Catalog Number

Catalog Number

1

PP01086

PP01086

—

Control fan

NEMA Type 12 control fan

Control module 2

SVX control module

1

CSBS0000000000

CSBS0000000000

—

Standard slot A I/O card

1

OPTA9

OPTA9

—

Standard slot B I/O card

1

OPTA2

OPTA2

—

Power board 3

1

VB00308-0004-2

VB00208-0003-5

—

1

VB00308-0007-2

VB00208-0004-5

—

1

VB00308-0008-2

VB00208-0005-5

—

1

—

VB00208-0007-5

—

1

—

VB00208-0009-5

—

1

—

VB00410-0012-5-ARV

—

1

KEYPAD-LOC/REM

KEYPAD-LOC/REM

—

Converter

Keypad 2

SVX/SPX keypad

Main fan 2

DC fan (main)

1

PP01060

PP01060

—

Other

Mounting kit, fixing kit

1

FR00040

FR00040

—

Mounting kit, fixing kit, N12 1

1

FR00079

FR00079

—

Control cover, plastic, N1

1

FR00006

FR00006

—

Quantity/
Drive

230V

480V

575V

Catalog Number

Catalog Number

Catalog Number

2
2
2
2
2
2
2
2
2
2
2
2

FR5 Spare Parts
Category

Description
1

Control fan

NEMA Type 12 control fan

1

PP01088

PP01088

—

Control module 2

SVX control module

1

CSBS0000000000

CSBS0000000000

—

Standard slot A I/O card

1

OPTA9

OPTA9

—

Standard slot B I/O card

1

OPTA2

OPTA2

—

Power board 3

1

VB00313-0017-2

VB00213-0016-5

—

1

VB00313-0025-2

VB00213-0022-5

—

1

VB00313-0031-2

VB00213-0031-5

—

SVX/SPX keypad

1

KEYPAD-LOC/REM

KEYPAD-LOC/REM

—

DC fan (main)

1

PP01061

PP01061

—

Converter

Keypad

2

Main fan 2
Other

Mounting kit, fixing kit

1

FR00050

FR00050

—

Mounting kit, fixing kit, N12 1

1

FR00081

FR00081

—

Control cover, plastic, N1

1

FR05011

FR05011

—

2
2
2
2
2
2
2
2
2

Notes
1 Only for NEMA Type 12/IP54 Type drives.
2 Factory recommended spare parts.
3 Select one part number based on the amperage rating of the drive. Please contact EatonCare at 877-ETN-CARE for assistance.

2
2
2
2
2
2
2
2

Volume 6—Solid-State Motor Control CA08100007E—May 2014 www.eaton.com

V6-T2-61

2.5

Adjustable Frequency Drives
SVX9000 Drives

2

FR6 Spare Parts

2

Category

Description

Quantity/
Drive

Control fan

NEMA Type 12 control fan 1

1

PP01049

PP01049

—

Control module 2

SVX control module

1

CSBS0000000000

CSBS0000000000

CSBS0000000000

Standard slot A I/O card

1

OPTA9

OPTA9

OPTA9

Standard slot B I/O card

1

OPTA2

OPTA2

OPTA2

Power board 3

1

VB00316-0048-2

VB00416-0038-5

VB00404-0004-6

1

VB00316-0061-2

VB00416-0045-5

VB00404-0005-6

2

1

—

VB00416-0061-5

VB00404-0007-6

2

1

—

—

VB00404-0010-6

1

—

—

VB00404-0013-6

2

1

—

—

VB00404-0018-6

1

—

—

VB00404-0022-6

2

1

—

—

VB00404-0027-6

1

—

—

VB00404-0034-6

2
2
2

2
2
2

Converter

2

—

—

S00930

Keypad 2

SVX/SPX keypad

1

KEYPAD-LOC/REM

KEYPAD-LOC/REM

KEYPAD-LOC/REM

Main fan 2

DC fan (main)

1

PP01062

PP01062

—

Other

Mounting kit, fixing kit

1

FR00060

FR00060

FR00060

Mounting kit, fixing kit, N12 1

1

FR00082

FR00082

FR00082

Control cover, plastic, N1

1

FR06011

FR06011

FR06011

Quantity/
Drive

230V

480V

575V

Description

Catalog Number

Catalog Number

Catalog Number

NEMA Type 12 control fan 1

1

PP01049

PP01049

PP01049

SVX control module

1

CSBS0000000000

CSBS0000000000

CSBS0000000000

Standard slot A I/O card

1

OPTA9

OPTA9

OPTA9

Standard slot B I/O card

1

OPTA2

OPTA2

OPTA2

Power board 3

1

VB00319-0075-2

VB00619-0072-5

VB00419-0041-6

1

VB00319-0088-2

VB00619-0087-5

VB00419-0052-6

1

VB00319-0114-2

VB00619-0105-5

—

FR7 Spare Parts

2

Category

2

Control fan
Control module

Converter

2

2
2
2
2

DC section

Bus capacitor

2

—

—

PP01041

Keypad 2

SVX/SPX keypad

1

KEYPAD-LOC/REM

KEYPAD-LOC/REM

KEYPAD-LOC/REM

Main fan 2

DC fan (main)

1

PP01063

PP01063

PP01063

Other

Mounting kit, fixing kit

1

FR07071

FR07071

FR07071

Mounting kit, fixing kit, N12 1

1

FR07072

FR07072

FR07072

Control cover, plastic, N1

1

FR07011

FR07011

FR07011

2
2
2

575V
Catalog Number

Bus capacitor

2

2

480V
Catalog Number

DC section

2

2

230V
Catalog Number

Notes
1 Only for NEMA Type 12/IP54 Type drives.
2 Factory recommended spare parts.
3 Select one part number based on the amperage rating of the drive. Please contact EatonCare at 877-ETN-CARE for assistance.

2
2
2
2
2
V6-T2-62

Volume 6—Solid-State Motor Control CA08100007E—May 2014 www.eaton.com

Adjustable Frequency Drives
SVX9000 Drives

2.5

FR8 Spare Parts
230V

480V

575V

Category

Description

Quantity/
Drive

Catalog Number

Catalog Number

Catalog Number

Control fan

NEMA Type 12 control fan 1

1

CP01180

CP01180

CP01180

Control module 2

SVX control module

1

CSBS0000000000

CSBS0000000000

CSBS0000000000

Standard slot A I/O card

1

OPTA9

OPTA9

OPTA9

Standard slot B I/O card

1

OPTA2

OPTA2

OPTA2

1

VB00722-0140-2-ANV

VB00636-0140-4-ANV

VB00422-0062-5-ANV

1

VB00722-0170-2-ANV

VB00636-0168-4-ANV

VB00422-0080-5-ANV

1

VB00722-0205-2-ANV

VB00636-0205-4-ANV

VB00422-0100-5-ANV

2

PP01175

PP01175

PP01127

Converter

Power board

3

IGBT
DC section

Bus capacitor

4

S00335

S00335

PP01041

Inverter

Diode

3

CP01268

CP01268

CP01373

Rectifier board

1

VB00227

VB00227

VB00427

Keypad 2

SVX/SPX keypad

1

KEYPAD-LOC/REM

KEYPAD-LOC/REM

KEYPAD-LOC/REM

Main AC fan

Fan AC

1

PP01123

PP01123

PP01123

Fan fuse

2

PP20202

PP20202

PP20202

Starting cap

1

S00734

S00734

S00734

Fan driver board AC

1

VB00599

VB00799

VB00799

Isolation transformer (fan)

1

S0000113

S0000113

S0000113

Main DC fan 2

DC fan

1

PP00071

PP00071

PP00071

DC power supply

1

S01016

S01016

S01016

Other

Front cover, N12 1

1

FR08079

FR08079

FR08079

Conduit plate, N12

1

FR08082

FR08082

FR08082

Front cover, N1

1

FR08106

FR08106

FR08106

2
2
2
2
2
2
2
2
2
2
2
2
2
2
2

Notes
1 Only for NEMA Type 12/IP54 Type drives.
2 Factory recommended spare parts.
3 Select one part number based on the amperage rating of the drive. Please contact EatonCare at 877-ETN-CARE for assistance.

2
2
2
2
2
2
2
2
2
2
2
2
2
2
2

Volume 6—Solid-State Motor Control CA08100007E—May 2014 www.eaton.com

V6-T2-63

2.5

Adjustable Frequency Drives
SVX9000 Drives

2

FR9 Spare Parts

2

Category

Description

Quantity/
Drive

Control fan

50 mm fan

1

PP09041

PP09041

PP09041

80 mm fan

1

PP01068

PP01068

PP01068

SVX control module

1

CSBS0000000000

CSBS0000000000

CSBS0000000000

2
2
2

Control module 1

Converter

2
2

480V

575V

Catalog Number

Catalog Number

Standard slot A I/O card

1

OPTA9

OPTA9

OPTA9

Standard slot B I/O card

1

OPTA2

OPTA2

OPTA2

Power module 2

1

FR09-0261-2-ANV

FR09-0261-4-ANV

FR09-0125-5-ANV

1

FR09-0300-2-ANV

FR09-0300-4-ANV

FR09-0144-5-ANV

1

—

—

FR09-0170-5-ANV

Driver board

1

S00583

S00583

S00583

Shunt board 2

6

—

VB00535

VB00537

6

—

VB00536

VB00542

2
2

230V
Catalog Number

6

—

—

VB00543

Balancing resistor

3

PP00052

PP00052

PP00052

2

Bus capacitor

8

S00335

S00335

PP01041

2

DC busbars DC–

1

FR09043

FR09043

FR09043

DC busbars DC+

1

FR09044

FR09044

FR09044

2

DC busbars connection

1

FR09045

FR09045

FR09045

DC busbars +/– insulator

1

FR09046

FR09046

FR09046

2

DC busbars –/con insulator

1

FR09047

FR09047

FR09047

Rectifier module

1

FR09826

FR09822

FR09823

Diode

3

CP01268

CP01268

CP01268

Rectifier board

1

—

VB00459

VB00460

SVX/SPX keypad

1

KEYPAD-LOC/REM

KEYPAD-LOC/REM

KEYPAD-LOC/REM

DC section

Inverter

2
2
2

Keypad 1
Main AC fan

2
2
2

Main DC fan 1

2

Other

2
2
2

Fan AC

1

PP01080

PP01080

PP01080

Fan fuse

2

PP20202

PP20202

PP20202

Starting cap

1

S00465

S00465

S00465

Fan driver board AC

1

VB00899

VB00399

VB00299

Isolation transformer (fan)

1

PP09056

PP09055

PP09055

DC fan

1

PP00072

PP00072

PP00072
S01017

DC power supply

1

S01017

S01017

Front cover power

1

FR09012

FR09012

FR09012

Front cover connection

1

FR09013

FR09013

FR09013

Front power conduit

1

FR09014

FR09014

FR09014

Notes
1 Factory recommended spare parts.
2 Select one part number based on the amperage rating of the drive. Please contact EatonCare at 877-ETN-CARE for assistance.

2
2
2
2
2
2
2
V6-T2-64

Volume 6—Solid-State Motor Control CA08100007E—May 2014 www.eaton.com

Adjustable Frequency Drives
SVX9000 Drives

2.5

FR10 Spare Parts
230V

480V

575V

Category

Description

Quantity/
Drive

Catalog Number

Catalog Number

Catalog Number

Control

Fiber board

1

—

S00451

S00451

ASIC board

1

—

S00457

S00457

Control fan

ASIC fan

1

—

PP01096

PP01096

Control module 1

SVX control module

1

—

CPBS0000000000

CPBS0000000000

Standard slot A I/O card

1

—

OPTA9

OPTA9

Standard slot B I/O card

1

—

OPTA2

OPTA2

1

—

FR10-0385-4-ANV

FR10-0261-5-ANV

1

—

FR10-0460-4-ANV

FR10-0325-5-ANV

1

—

FR10-0520-4-ANV

FR10-0385-5-ANV

1

—

—

FR10-0416-5-ANV

Driver board

1

—

S00450

S00450

Driver adapter board

1

—

VB00330

VB00330

Shunt board 2

6

—

VB00497

VB00510

6

—

VB00498

VB00511

6

—

VB00537

VB00545

Top cover

1

—

FR10340

FR10340

Side cover

2

—

FR10341

FR10341

Balancing resistor

2

—

PP13027

PP13028

DC busbars kit (right)

1

—

S0000005

S0000005

Bus capacitor

12

—

S00335

S00336

Rectifier module

1

—

FR10823

FR10823

Charging resistor

1

—

PP00066

PP00066

Diode

3

—

PP01177

PP01177

Rectifier board

1

—

S00591

S00592

SVX/SPX keypad

1

—

KEYPAD-LOC/REM

KEYPAD-LOC/REM

Converter

Covers

DC section

Inverter

Keypad 1
Main AC fan

Main DC fan 1

Power module

2

Fan assembly (left)

1

—

FR10846

FR10846

Fan assembly (right)

1

—

FR10847

FR10847

Fan AC

2

—

PP01080

PP01080

Fan fuse

4

—

PP20202

PP20202

Starting cap

2

—

S00528

S00528

Fan driver board AC

2

—

VB00299

VB00299

Isolation transformer (left)

1

—

FR10844

FR10844

Isolation transformer (right)

1

—

FR10845

FR10845

DC fan

2

—

PP00072

PP00072

DC power supply

2

—

S01017

S01017

2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2

Notes
1 Factory recommended spare parts.
2 Select one part number based on the amperage rating of the drive. Please contact EatonCare at 877-ETN-CARE for assistance.

2
2
2
2
2
2
2

Volume 6—Solid-State Motor Control CA08100007E—May 2014 www.eaton.com

V6-T2-65

2.5

Adjustable Frequency Drives
SVX9000 Drives

2

FR11 Spare Parts

2

Category
Control

S00451

—

S00457

S00457

Control fan

ASIC fan

1

—

PP01096

PP01096

Control module 1

SVX control module

1

—

CPBS0000000000

CPBS0000000000

Standard slot A I/O card

1

—

OPTA9

OPTA9

Standard slot B I/O card

1

—

OPTA2

OPTA2

Power module 2

1

—

FR11-0590-4-ANV

FR11-0460-5-ANV

1

—

FR11-0650-4-ANV

FR11-0502-5-ANV

1

—

FR11-0730-4-ANV

FR11-0590-5-ANV

1

—

S00452

S00452

1

—

VB00330

VB00330

9

—

VB00513

VB00512

9

—

VB00514

VB00546

9

—

VB00538

VB00547

1

—

FR11345

FR11345

Converter

Driver board
Driver adapter board
Shunt board

Covers
DC section

2
2
2

Balancing resistor

3

—

PP13027

PP13027

DC busbars kit (right)

3

—

S0000005

S0000005

18

—

S00335

S00335

1

—

FR10823

FR10823

Diode

3

—

PP01177

PP01177

Rectifier board

1

—

S00591

S00591

Keypad 1

SVX/SPX keypad

1

—

KEYPAD-LOC/REM

KEYPAD-LOC/REM

Main AC fan

Fan assembly (right)

3

—

FR10847

FR10847

Fan AC

3

—

PP01080

PP01080

Fan fuse

4

—

PP20202

PP20202

Starting cap

3

—

S00530

S00530

Fan driver board AC

3

—

VB00299

VB00299

2

2

Top cover

Bus capacitor

2

2

2

Rectifier module

Inverter

2

2

S00451

—

2

2

575V
Catalog Number

1

2

2

480V
Catalog Number

1

2

2

230V
Catalog Number

Fiber board

2
2

Quantity/
Drive

ASIC board

2
2

Description

Main DC fan 1

Isolation transformer (right)

3

—

FR10845

FR10845

DC fan

2

—

PP00072

PP00072

DC power supply

2

—

S01017

S01017

Notes
1 Factory recommended spare parts.
2 Select one part number based on the amperage rating of the drive. Please contact EatonCare at 877-ETN-CARE for assistance.

2
2
2
2
2
2
2
2
2
V6-T2-66

Volume 6—Solid-State Motor Control CA08100007E—May 2014 www.eaton.com

Adjustable Frequency Drives
SVX9000 Drives

2.5

FR12 Spare Parts
230V

480V

575V

Category

Description

Quantity/
Drive

Catalog Number

Catalog Number

Catalog Number

Control

Fiber board

2

—

S00451

S00451

ASIC board

2

—

S00457

S00457

Star coupler

1

—

S00593

S00593

ASIC fan

2

—

PP01096

PP01096

SVX control module

1

—

CPBS0000000000

CPBS0000000000

Standard slot A I/O card

1

—

OPTA9

OPTA9

Standard slot B I/O card

1

—

OPTA2

OPTA2

Power module 2

1

—

FR12-0820-4-ANV

FR12-0650-5-ANV

1

—

FR12-0920-4-ANV

FR12-0750-5-ANV

1

—

FR12-1030-4-ANV

FR12-0820-5-ANV

Control fan
Control module

Converter

Covers

DC section

Inverter

Keypad 1
Main AC fan

Main DC fan

1

1

Driver board

2

—

S00450

S00450

Driver adapter board

2

—

VB00330

VB00330

Shunt board

12

—

VB00498

VB00511

Top cover

2

—

FR10340

FR10340

Side cover

4

—

FR10341

FR10341

Balancing resistor

4

—

PP13027

PP13027

DC busbars kit (right)

2

—

S0000005

S0000005

Bus capacitor

24

—

S00335

S00336

Rectifier module

2

—

FR10823

FR10823

Diode

3

—

PP01177

PP01177

Rectifier board

2

—

S00591

S00591

SVX/SPX keypad

1

—

KEYPAD-LOC/REM

KEYPAD-LOC/REM

Fan assembly (left)

2

—

FR10846

FR10846

Fan assembly (right)

2

—

FR10847

FR10847

Fan AC

4

—

PP01080

PP01080

Fan fuse

8

—

PP20202

PP20202

Starting cap

4

—

S00528

S00528

Fan driver board AC

4

—

VB00299

VB00299

Isolation transformer (left)

2

—

FR10844

FR10844

Isolation transformer (right)

2

—

FR10845

FR10845

DC fan

4

—

PP00072

PP00072

DC power supply

4

—

S01017

S01017

2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2

Notes
1 Factory recommended spare parts.
2 Select one part number based on the amperage rating of the drive. Please contact EatonCare at 877-ETN-CARE for assistance.

2
2
2
2
2
2
2
2
2

Volume 6—Solid-State Motor Control CA08100007E—May 2014 www.eaton.com

V6-T2-67

2.5

Adjustable Frequency Drives
SVX9000 Drives

2

FR13 Spare Parts

2

Category

Description

Control

Quantity/
Drive

230V

480V

575V

Catalog Number

Catalog Number

Catalog Number

ASIC board

1

—

S00457

S00457

ASIC assembly

1

—

60S01030

60S01030

ASIC fan

1

—

PP01096

PP01096

SVX control module

1

—

CPBS0000000000

CPBS0000000000

Standard slot A I/O card

1

—

OPTA9

OPTA9

Standard slot B I/O card

1

—

OPTA2

OPTA2

Power module 2

3

—

FI13-1150-4-ANV

FR13-1030-5-ANV

3

—

FI13-1300-4-ANV

FR13-1180-5-ANV

3

—

FI13-1450-4-ANV

FR13-920-5-ANV

Driver board

3

—

S00454

S00454

Driver adapter board

2

—

VB00330

VB00330

18

—

VB00505

VB00516

18

—

VB00514

VB00517

18

—

VB00541

VB00547

Top cover

3

—

FI10001

FI10001

Side cover

3

—

FI10003

FI10003

Balancing resistor

6

—

PP13034

PP13034

Bus capacitor

36

—

S00335

S00336

DC busbars kit

3

—

FI13329

FI13329

Rectifier module

2

—

FR10823

FR10823

Diode

3

—

PP01177

PP01177

Rectifier board

2

—

S00591

S00591

Keypad 1

SVX/SPX keypad

1

—

KEYPAD-LOC/REM

KEYPAD-LOC/REM

Main AC fan

Fan assembly (left)

3

—

FI13301

FI13301

Fan AC

3

—

PP01080

PP01080

2

Fan fuse

6

—

PP20202

PP20202

2

Starting cap

3

—

S00520

S00520

Fan driver board AC

3

—

VB00299

VB00299

Isolation transformer

3

—

PP10057

PP10057

2
2

Control fan
Control module

2
2

Converter

1

2
2
2
2
2
2
2

Shunt board

Covers

DC section

Inverter

2
2
2

2
2
2

Main DC fan 1

2

DC fan

4

—

PP00072

PP00072

DC power supply

4

—

S01017

S01017

Notes
1 Factory recommended spare parts.
2 Select one part number based on the amperage rating of the drive. Please contact EatonCare at 877-ETN-CARE for assistance.

2
2
2
2
2
2
2
2
2
V6-T2-68

Volume 6—Solid-State Motor Control CA08100007E—May 2014 www.eaton.com

Adjustable Frequency Drives
SVX9000 Drives

2.5

FR14 Spare Parts
230V

480V

575V

Category

Description

Quantity/
Drive

Catalog Number

Catalog Number

Catalog Number

Control

ASIC board

2

—

S00457

S00457

Star coupler

1

—

S00593

S00593

ASIC assembly

2

—

60S01030

60S01030

Star coupler kit

1

—

FR10860

FR10860

Control fan

ASIC fan

2

—

PP01096

PP01096

Control module 1

SVX control module

1

—

CPBS0000000000

CPBS0000000000

Converter

Covers

DC section

Inverter

Standard slot A I/O card

1

—

OPTA9

OPTA9

Standard slot B I/O card

1

—

OPTA2

OPTA2

Power module 2

1

—

FR14-1770-4-ANV

FR14-1500-5-ANV

1

—

FR14-2150-4-ANV

FR14-1900-5-ANV

1

—

FR14-2700-4-ANV

FR14-2250-5-ANV

Driver board

6

—

S00454

S00454

Driver adapter board

2

—

VB00330

VB00330

Shunt board 2

36

—

VB00541

VB00516

36

—

—

VB00517

Top cover

6

—

FI10001

FI10001

Side cover

6

—

FI10003

FI10003

Balancing resistor

6

—

PP13034

PP13034

Bus capacitor

72

—

S00335

S00336

DC busbars kit

6

—

FI13329

FI13329

Rectifier module

2

—

FR10823

FR10823

Diode

3

—

PP01177

PP01177

Rectifier board

2

—

S00591

S00591

Keypad 1

SVX/SPX keypad

1

—

KEYPAD-LOC/REM

KEYPAD-LOC/REM

Main AC fan

Fan assembly (left)

6

—

FI13301

FI13301

Main DC fan

1

Fan AC

6

—

PP01080

PP01080

Fan fuse

12

—

PP20202

PP20202

Starting cap

6

—

S00520

S00520

Fan driver board AC

6

—

VB00299

VB00299

Isolation transformer

6

—

PP10057

PP10057

DC fan

6

—

PP00072

PP00072

DC power supply

6

—

S01017

S01017

2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2

Notes
1 Factory recommended spare parts.
2 Select one part number based on the amperage rating of the drive. Please contact EatonCare at 877-ETN-CARE for assistance.

2
2
2
2
2
2
2
2
2

Volume 6—Solid-State Motor Control CA08100007E—May 2014 www.eaton.com

V6-T2-69

2.5

Adjustable Frequency Drives
SVX9000 Drives

2

Technical Data and Specifications

2

SVX9000 Drives

2

Input Ratings
Input voltage (Vin)

+10%/–15%

2

Input frequency (fin)

50/60 Hz (variation up to 45–66 Hz)

2

Connection to power

Once per minute or less (typical operation)

2

Output Ratings

2
2
2
2
2
2

Description

Specification

Description

Specification

Control Connections

High withstand rating

100 kAIC

Output voltage

0 to Vin

Analog input voltage

0 to 10V, R = 200 kohms (–10 to 10V joystick control) resolution
0.1%; accuracy ±1%

Analog input current

0(4) to 20 mA; Ri—250 ohms differential

Digital inputs (6)

Positive or negative logic; 18 to 30 Vdc

Auxiliary voltage

+24V ±15%, max. 250 mA

Output reference voltage

+10V +3%, max. load 10 mA

Analog output

0(4) to 20 mA; RL max. 500 ohms;
resolution 10 bit; accuracy ±2%

Continuous output current

IH rated 100% at 122°F (50°C), FR9 and below
IL rated 100% at 104°F (40°C), FR9 and below
IH/IL 100% at 104°F (40°C), FR10 and above

Digital outputs

Open collector output, 50 mA/48V

Overload current (IH/IL)

150% IH, 110% IL for 1 min.

Relay outputs

Output frequency

0 to 320 Hz

Two programmable Form C relay outputs
switching capacity: 24 Vdc/8A, 250 Vac/8A, 125 Vdc/0.4A

Frequency resolution

0.01 Hz

Initial output current (IH)

250% for 2 seconds

Control Characteristics
Control method

Frequency control (V/f)
Open loop: Sensorless vector control
Closed loop: SPX9000 drives only

Protections
Overcurrent protection

Trip limit 4.0 x IH instantaneously

Overvoltage protection

Yes

Undervoltage protection

Yes

Earth fault protection

In case of earth fault in motor or motor cable, only the
frequency converter is protected

Input phase supervision

Trips if any of the input phases are missing

Motor phase supervision

Trips if any of the output phases are missing

Overtemperature protection

Yes

Switching frequency
Frame 4–6
Frame 7–12

Adjustable with parameter 2.6.9
1–16 kHz; default 10 kHz
1–10 kHz; default 3.6 kHz

2

Frequency reference

Analog input: Resolution 0.1% (10-bit), accuracy ±1% V/Hz
Panel reference: Resolution 0.01 Hz

Motor overload protection

Yes

2

Field weakening point

30–320 Hz

Motor stall protection

Yes

Acceleration time

0–3000 sec.

Motor underload protection

Yes

2

Deceleration time

0–3000 sec.

Short-circuit protection

Yes (+24V and +10V reference voltages)

2

Braking torque

DC brake: 30% x Tn (without brake option)

Ambient Conditions

2

2

Ambient operating
temperature

14°F (–10°C), no frost to 122°F (50°C) IH (FR4–FR9)
14°F (–10°C), no frost to 104°F (40°C) IH (FR10 and up)
14°F (–10°C), no frost to 104°F (40°C) IL (all frames)

Storage temperature

Standard I/O Specifications
Description

Specification

–40° to 158°F (–40° to 70°C)

Six–digital input
programmable

24V: “0” <10V, “1” >18V,Ri >5 kohms

Relative humidity

0 to 95% RH, noncondensing, non-corrosive,
no dripping water

Two–analog input
configurable w/jumpers

Voltage: 0–±10V, Ri >200 kohms
Current: 0 (4)–20 mA, Ri = 250 ohms

Air quality

Chemical vapors: IEC 721-3-3, unit in operation, class 3C2;
Mechanical particles: IEC 721-3-3, unit in operation, class 3S2

Two–digital output
programmable

Form C relays 250 Vac
30 Vdc 2 amp resistive

Altitude

100% load capacity (no derating) up to 3280 ft (1000m);
1% derating for each 328 ft (100m) above 3280 ft (1000m);
max. 9842 ft (3000m)

One–analog output
programmable
configurable w/jumper

0–20 mA, RL max. 500 ohms 10 bits ±2%

Vibration

One digital output
programmable

Open collector 48 Vdc 50 mA

2

EN 50178, EN 60068-2-6; 5 to 50 Hz, displacement amplitude
1 mm (peak) at 3 to 15.8 Hz, max. acceleration amplitude
1G at 15.8 to 150 Hz

Shock

EN 50178, EN 60068-2-27 UPS Drop test (for applicable UPS
weights) Storage and shipping: max. 15G, 11 ms (in package)

2

Enclosure class

NEMA 1/IP21 or NEMA 12/IP54, open chassis/IP20

2
2
2
2
2

2
2
2
2
2
V6-T2-70

Volume 6—Solid-State Motor Control CA08100007E—May 2014 www.eaton.com

2.5

Adjustable Frequency Drives
SVX9000 Drives

Dimensions
Approximate Dimensions in Inches (mm)

2

9000X Open Drives

2
2

NEMA Type 1/IP21 and NEMA Type 12/IP54, FR4, FR5 and FR6
W1
W2

D1

2

R2

2

R1
EATON

2
2
2

H1
H3

2

H2

2
2
2

R2

2
2
2
2

Knockouts

2

D3

2

D2

2
hp (IH)

H1

H2

H3

D1

D2

D3

W1

W2

R1 Dia.

R2 Dia.

Weight
Lbs (kg)

Knockouts at Inches (mm)
N1 (O.D.)

2

230V

3/4–3

11.5
(292)

7.5
(190)

3.0
(77)

4.9
(126)

5.0
(128)

3.9
(100)

0.3 (7)

11.0 (5)

3 @ 1.1 (28)

2

1–5

12.3
(313)

0.5 (13)

480V

12.9
(327)

16.5
(419)

16.0
(406)

15.3
(389)

8.4
(214)

3.9
(100)

5.8
(148)

5.6
(143)

3.9
(100)

0.5 (13)

22.0
(558)

21.3
(541)

20.4
(519)

9.3
(237)

4.2
(105)

6.5
(165)

7.6
(195)

5.8
(148)

0.6 (15.5)

Voltage
FR4

2

FR5
230V

5–7-1/2

480V

7-1/2–15

0.3 (7)

17.9 (8)

2

2 @ 1.5 (37)
1 @ 1.1 (28)

2

FR6
230V

10–15

480V

20–30

575V

2–25

0.4 (9)

40.8 (19)

2

3 @ 1.5 (37)

2
2
2
2
2
Volume 6—Solid-State Motor Control CA08100007E—May 2014 www.eaton.com

V6-T2-71

2.5
2
2

Adjustable Frequency Drives
SVX9000 Drives

Approximate Dimensions in Inches (mm)
NEMA Type 1/IP21 and NEMA Type 12/IP54 with Flange Kit, FR4, FR5 and FR6

2
2

W2

2

Dia. A

2

H2
H1

2

W1

2
2
2

H4
D1

2
2

H5
D2

2
2

H3
Dia. B

H7

2
2
2

W5

Flange Opening
FR4 to FR6

H8

H6

W4 W3

2
2
2

FR4, FR5 and FR6 with Flange Kit

2

W1

2

5.0 (128)

2

5.6 (143)

2
2
2
2

H9

W2

H1

H2

H3

H4

H5

D1

D2

Dia. A

4.5 (113)

13.3 (337)

12.8 (325)

12.9 (327)

1.2 (30)

0.9 (22)

7.5 (190)

3.0 (77)

0.3 (7)

4.7 (120)

17.0 (434)

16.5 (420)

16.5 (419)

1.4 (36)

0.7 (18)

8.4 (214)

3.9 (100)

0.3 (7)

6.7 (170)

22.0 (560)

21.6 (549)

22.0 (558)

1.2 (30)

0.8 (20)

9.3 (237)

4.2 (106)

0.3 (7)

FR4

FR5

FR6
7.7 (195)

Flange Opening, FR4 to FR6
W3

W4

W5

H6

H7

H8

H9

Dia. B

4.5 (113)

—

12.4 (315)

12.8 (325)

—

0.2 (5)

0.3 (7)

4.7 (120)

—

16.2 (410)

16.5 (420)

—

0.2 (5)

0.3 (7)

6.7 (170)

6.2 (157)

21.2 (539)

21.6 (549)

0.3 (7)

0.2 (5)

0.3 (7)

FR4
4.8 (123)

2

FR5

2

FR6

5.3 (135)

7.3 (185)

2
V6-T2-72

Volume 6—Solid-State Motor Control CA08100007E—May 2014 www.eaton.com

2.5

Adjustable Frequency Drives
SVX9000 Drives

Approximate Dimensions in Inches (mm)

2

NEMA Type 1/IP21 and NEMA Type 12/IP54, FR7

2

H1
H2

2
2
2

W2 W1

2
2
R2

R1

2

R2

2
2

Knockouts

2

H3

2

D2

2
2

D1
D3

2
2

Voltage

hp (IH)

H1

H2

H3

D1

D2

D3

W1

W2

R1 Dia.

R2 Dia.

Weight
Lbs (kg)

Knockouts at Inches (mm)
N1 (O.D.)

2

230V

20–30

24.8 (630)

24.2 (614)

23.2 (590)

10.1 (257)

3.0 (77)

7.3 (184)

9.3 (237)

7.5 (190)

0.7 (18)

0.4 (9)

77.2 (35)

3 at 1.5 (37)

480V

40–60

2

575V

30–40

2
2
2
2
2
2
2
2
2
2
2
2
Volume 6—Solid-State Motor Control CA08100007E—May 2014 www.eaton.com

V6-T2-73

2.5
2
2

Adjustable Frequency Drives
SVX9000 Drives

Approximate Dimensions in Inches (mm)
NEMA Type 1/IP21 and NEMA Type 12/IP54, FR8
H1
H2

2
2
2
2

W1 W2

2
2
2
2
2

R2
R1
H3

2
2
2
2

D1

2
2
2
2
2
2
2

Voltage

hp (IH)

D1

H1

H2

H3

W1

W2

R1 Dia.

R2 Dia.

Weight
Lbs (kg)

230V

40–60

13.5 (344)

30.1 (764)

28.8 (732)

28.4 (721)

11.5 (291)

10 (255)

0.7 (18)

0.4 (9)

127 (58)

480V

75–125

575V

50–75

2
2
2
2
2
2
2
2
V6-T2-74

Volume 6—Solid-State Motor Control CA08100007E—May 2014 www.eaton.com

2.5

Adjustable Frequency Drives
SVX9000 Drives

Approximate Dimensions in Inches (mm)

2

NEMA Type 1/IP21 and NEMA Type 12/IP54, with Flange Kit, FR7 and FR8
H6

H4

H4

H5

2

Dia. A

2
2
2

W4 W2

2
2
2

H2
H1

W3
W1

H7

2
2
2
2

D1

2

D2

2
2

H3
H12

H9

H9

H10

H11

2
2

Flange Opening
FR7/FR8

W5 W6

2

W7
Dia. B

2

H8

H13
W1

2

W3

W4

H1

H2

H3

H4

H5

H6

H7

D1

D2

Dia. A

6.8 (175)

10.6 (270)

10.0 (253)

24.9 (652)

24.8 (632)

24.8 (630)

7.4 (189)

7.4 (189)

0.9 (23)

0.8 (20)

10.1 (257)

4.6 (117)

0.3 (6)

2

—

14.0 (355)

13.0 (330)

32.8 (832)

—

29.3 (745)

10.2 (258)

10.4 (265)

1.7 (43)

2.2 (57)

13.5 (344)

4.3 (110)

0.4 (9)

2

FR7
9.3 (237)
FR8
11.2 (285)

2

Flange Opening, FR7 and FR8
W5

W6

W7

H8

H9

H10

H11

H12

H13

Dia. B

2

6.9 (175)

10.0 (253)

24.4 (619)

7.4 (189)

7.4 (189)

1.4 (35)

1.3 (32)

1.0 (25)

0.3 (6)

2

—

13.0 (330)

31.9 (810)

10.2 (258)

10.4 (265)

—

—

1.3 (33)

0.4 (9)

2

FR7
9.2 (233)
FR8
11.9 (301)

2

W2

2
2
2
Volume 6—Solid-State Motor Control CA08100007E—May 2014 www.eaton.com

V6-T2-75

2.5
2
2

Adjustable Frequency Drives
SVX9000 Drives

Approximate Dimensions in Inches (mm)
NEMA Type 1/IP21 and NEMA Type 12/IP54 FR9
H6

H4

H3

W4

2

W5

2

W5

W2

W3

W1

PE

2

B- B+ /R+ R-

2

2
2

H2

2

H5

D3

H1
Dia.

2
2
2

D1

D2

2
2
2
2
2
2

Voltage

hp (IH)

W1

W2

W3

W4

H1

H2

H3

H4 1

D1

D2

D3

Dia.

230V

75–100

480V

150–200

18.9
(480)

15.7
(400)

0.4
(9)

2.1
(54)

45.3
(1150)

44.1
(1120)

0.6
(16)

7.4
(188)

14.2
(361.5)

13.4
(340)

11.2
(285)

0.8
(21)

575V

100–175

Note
1 Brake resistor terminal box (H6) included when brake chopper ordered.

2
2
2
2
2
2
2
2
2
2
2
2
V6-T2-76

Volume 6—Solid-State Motor Control CA08100007E—May 2014 www.eaton.com

Weight
Lbs (kg)
321.9 (146)

2.5

Adjustable Frequency Drives
SVX9000 Drives

Approximate Dimensions in Inches (mm)

2

NEMA Type 1/IP21 and NEMA Type 12/IP54, FR9 with Flange Kit

2

H7

2
2

W5

2

W1

2
2
2
2

Dia.

2
2

D1
D2

2
2

D3
H4

H5

H3

2

H4

H2

H3

H3

2

H5

2
2

W4
Flange Opening
FR9

W3

2
W2

2

W4

2
2
2

H1

H6

.20 (5)
Dia.
W1

W2

W3

W4

W5

H1

H2

H3

20.9 (530)

20.0 (510)

19.1 (485)

7.9 (200)

0.2 (5.5)

51.7 (1312) 45.3 (1150) 16.5 (420)

H4

H5

H6

H7

D1

D2

D3

Dia.

3.9 (100)

1.4 (35)

0.4 (9)

0.1 (2)

24.9 (362)

13.4 (340)

4.3 (109)

0.8 (21)

2
2
2
2
2
2
2
2

Volume 6—Solid-State Motor Control CA08100007E—May 2014 www.eaton.com

V6-T2-77

2.5
2
2

Adjustable Frequency Drives
SVX9000 Drives

Approximate Dimensions in Inches (mm)
NEMA Type 1/IP21 and NEMA Type 12/IP54, FR10 Freestanding
W7

2

W4

W5
W6

W6

W4

2
2

Dia. 3
Dia. 1

2

Dia. 2
D6 D7

D3 D2
D5

2

D4

2

W2
W3

2

W1

2

W3

W3 W3

W2

D1

2
2
2
2
2
2
2

H1
H2

2
2
2

Operator
(Shown with
Optional
Disconnect)

2
2

H3

2
2
2
2
2

W1

W2

W3

W4

W5

W6

W7

H1

H2

H3

D1

23.43
(595)

2.46
(62.5)

4.53
(115)

0.79
(20)

5.95
(151)

2.95
(75)

30.11
(79)

79.45
(2018)

74.80
(1900)

20.18 23.70
(512.5) (602)

D2

D3

D4

D5

D6

D7

Dia. 1

Dia. 2

Dia. 3

Weight
Lbs (kg)

17.44
(443)

19.02
(483)

0.47
(12)

11.22
(285)

17.60
(447)

20.08
(510)

0.83
(21)

1.89
(48)

0.43
(11)

857
(389)

2
2
2
V6-T2-78

Volume 6—Solid-State Motor Control CA08100007E—May 2014 www.eaton.com

2.5

Adjustable Frequency Drives
SVX9000 Drives

Approximate Dimensions in Inches (mm)

2

FR10 Open Chassis 1

2

H3
H4

H5

2

W3

2
2

W2

W1

W5

2
2
2
2

H7

2

W4

H6
H2
H1

2
2
2
2

D3

D4

D2

2

D1

2
2
2

Voltage

hp (IH)

W1

W2

W3

W4

W5

H1

H2

H3

H4

H5

H6

H7

D1

D2

D3

D4

Weight
Lbs (kg)

480V

250–350

575V

200–300

19.7
(500)

16.7
(425)

1.2
(30)

2.6
(67)

12.8
(325)

45.9
(1165)

44.1
(1121)

34.6
(879)

33.5
(850)

0.7
(17)

24.7
(627)

10.8
(275)

19.9
(506)

17.9
(455)

16.7
(423)

16.6
(421)

518
(235)

Note
1 9000X FR12 is built of two FR10 modules. Please refer to SPX9000 installation manual for mounting instructions.

2
2
2
2
2
2
2
2
2
2
2
2

Volume 6—Solid-State Motor Control CA08100007E—May 2014 www.eaton.com

V6-T2-79

2.5
2
2

Adjustable Frequency Drives
SVX9000 Drives

Approximate Dimensions in Inches (mm)
NEMA Type 1/IP21, FR11 Freestanding Drive
W5

2

W8
W6 W6 W6 W7 W7 W6 W6 W6

W4

2
2

Dia. 3
Dia. 1

2

Dia. 2

D3

D5

2

D2

2

W2

D4

W3

2

W1

W3

W3

W3

W2

D1

2
2
2
2
2
2
2
2

H1
H2

2
2
Operator
(Shown with
Optional
Disconnect)

2
2
2

H3

2
2
2
2

Voltage hp (IH)
480

W1

400–550 31.26
(794)

W2

W3

W4

W5

W6

W7

W8

H1

H2

H3

D1

2.40
(61)

6.50
(165)

0.79
(20)

3.43
(87)

2.95
(75)

2.52
(64)

1.18
(30)

79.45 74.80 20.18 23.70
(2018) (1900) (512.5) (602)

D2

D3

D4

D5

Dia. 1 Dia. 2 Dia. 3

11.22
(285)

19.09
(485)

0.47
(12)

17.60
(447)

0.83
(21)

2
2
2
2
V6-T2-80

Volume 6—Solid-State Motor Control CA08100007E—May 2014 www.eaton.com

1.89
(48)

Weight
Lbs (kg)

0.35 x 0.43 526
(9 x 11)
(239)

Adjustable Frequency Drives
SVX9000 Drives

2.5

Approximate Dimensions in Inches (mm)

2

FR11 Open Chassis

2

H2
W3

W3

W2

W2

2
2
2
2

W2

2

W2

2

Shown without
terminal cover

2
2
2

H1

2
2
2
2

W1

2
2
2
2
2
2
2

D1

D2

2
2
Voltage

hp (IH)

W1

W2

W3

H1

H2

D1

D2

Weight
Lbs (kg)

2

480V

400–550

27.9 (709)

8.86 (225)

2.6 (67)

45.5 (1155)

33.5 (850)

19.8 (503)

18.4 (468)

833 (378)

575V

400–500

2
2
2
2
2

Volume 6—Solid-State Motor Control CA08100007E—May 2014 www.eaton.com

V6-T2-81

2.5
2
2

Adjustable Frequency Drives
SVX9000 Drives

Approximate Dimensions in Inches (mm)
FR13, Open Chassis Inverter
W3

2

D6

Dia. 4

2

D8

2

D7

2
D5

2

W4 W4 W4 W4 W4 Dia. 1

D1

2

D2

D6

W1

2
2
2

H3

H1

H4

2
2
2

H2

2

Dia. 2

Dia. 3
W2

W2

W2

W2

D4
D4

H5

2
2
2

Dia. 3

2

D3

2
2
2
2

W1

W2

W3

W4

W5

H1

H2

H3

H4

H5

27.87
(708)

5.91
(150)

26.65
(677)

4.57
(116)

3.35
(85)

41.54 2.46 39.86 41.34 0.79
(1055) (62.5) (1012.5) (1050) (20)

W5

W5

W5

D1

D2

D3

D4

D5

D6

D7

D8

Dia.
2

Dia.
3

Dia.
4

Weight
Lbs (kg)

21.77
(553)

0.51
(13)

0.63
(16)

1.97
(50)

1.06
(27)

1.57
(40)

5.91
(150)

9.64
0.35x0.59 0.18
(244.8) (9x15)
(4.6)

0.51
(13)

0.37
(9.5)

683
(310)

Notes
9000X FR14 is built of two FR13 modules. Please refer to SPX9000 installation manual for mounting instructions.
FR13 is built from an inverter module and a converter module. Please refer to SPX9000 installation manual for mounting instructions.

2
2
2
2
2
2
2
V6-T2-82

Volume 6—Solid-State Motor Control CA08100007E—May 2014 www.eaton.com

Dia.
1

2.5

Adjustable Frequency Drives
SVX9000 Drives

Approximate Dimensions in Inches (mm)

2

FR13, Open Chassis Converter
Dia. 3

2

D9

2

D8

2

D7

2

W3

2

D6
Dia. 1 W4

W4

W4

D1

D2

W1

2
2
2
2
2

H4

H1

H3

2
2
2
2

H2
W2

D4

W2

D5 D5

2

H5
Dia. 2

2
2
2

Dia. 2

2

D3

H2

H3

H4

H5

W5

W1

W2

W3

W4

W5

H1

D1

18.74
(476)

5.91
(150)

17.52
(445)

4.57
(116)

3.35
(85)

41.54 2.46 39.86 41.34 0.69 14.69
(1055) (62.5) (1012.5) (1050) (17.5) (373)

W5

D2

D3

D4

0.51
(13)

0.73 6.42
(18.5) (163)

Weight
Dia. 2 Dia. 3 Lbs (kg)

D5

D6

D7

D8

D9

Dia. 1

2.56
(65)

1.06
(27)

1.57
(40)

5.91
(150)

5.24
(133)

0.35x0.59 0.51
(9x15)
(13)

0.37
(9.5)

295
(134)

2
2
2
2

Number of Input Units
480V
Catalog Number

hp

Input
Modules

690V
Catalog Number

hp

Input
Modules

SPX800A0-4A2N1

800

2

SPX800A0-5A2N1

800

2

SPX900A0-5A2N1

900

2

SPXH10A0-5A2N1

1000

2

2
2
2
2
2
2

Volume 6—Solid-State Motor Control CA08100007E—May 2014 www.eaton.com

V6-T2-83

2.5
2
2

Adjustable Frequency Drives
SVX9000 Drives

Approximate Dimensions in Inches (mm)
FR13, Open Chassis Converter—900/1000 hp 480V
Dia. 4

W3

2

D9

2

D8

2

D7

2
2

D6
Dia. 1 W4

W4

W4

W4

W4

D1

W1

D2

2
2
2
2

H1

H3

H4

2
2
2
2

H2

2

Dia. 2

W2

D3

W5

W2

W2

D4

W2

D5 D5

2

H5
Dia. 3

2
2
2
2
2
2

W1

W2

W3

W4

W5

H1

H2

H3

H4

H5

D1

27.87
(708)

5.91
(150)

26.65
(677)

4.57
(116)

3.35
(85)

41.54 2.46 39.86
41.34 0.69 14.69
(1055) (62.5) (1012.5) (1050) (17.5) (373)

W5

D2

D3

D4

D5

0.51
(13)

0.73 6.42 2.56
(18.5) (163) (65)

W5
D6

D7

D8

Dia.
2

Dia.
3

Dia.
4

Weight
Lbs (kg)

1.06
(27)

1.57
(40)

5.91 5.24 0.35x0.59 0.18
(150) (133) (9x15)
(4.6)

0.51
(13)

0.37
(9.5)

443
(201)

2

Number of Input Units

2

480V
Catalog Number

hp

Input
Modules

2

SPX900A0-4A2N1

900

3

SPXH10A0-4A2N1

1000

3

V6-T2-84

Volume 6—Solid-State Motor Control CA08100007E—May 2014 www.eaton.com

2
2
2
2

D9

Dia.
1

Adjustable Frequency Drives
SVX9000 Drives

2.5

Approximate Dimensions in Inches (mm)

2

AC Choke Dimensions

2

Choke Types
Catalog Number

Frame Size

Choke Type 1

Catalog Number

Voltage Range 380–500V
SPX 250 4

SPX 200 5

SPX 300 4

CHK0520

SPX 250 5

CHK0400

SPX 350 4

CHK0520

SPX 300 5

CHK0400

FR10

FR11

FR10

CHK0261

2 x CHK0400

SPX 400 5

SPX 500 4

2 x CHK0400

SPX 450 5

CHK0520

SPX 550 4

2 x CHK0400

SPX 500 5

2 x CHK0400

SPX 600 4

FR12

FR11

2 x CHK0520

SPX 550 5
SPX 600 5

2 x CHK0520

SPX 700 5

2 x CHK0400

SPX 800 5

SPX 900 4

3 x CHK0520

SPX 900 5

2 x CHK0400

SPX H10 4

3 x CHK0520

SPX H10 5

2 x CHK0400

4 x CHK0520

SPX H13 5

6 x CHK0400

SPX H15 5

SPX 700 4

SPX H12 4

FR13

FR14

SPX H16 4

2
2

CHK0520

2 x CHK0520

SPX 650 4

SPX 800 4

2

Voltage Range 525–690V
CHK0400

SPX 400 4

2

Choke Type 1

Frame Size

FR12

2
2

2 x CHK0400
2 x CHK0400

2

2 x CHK0400
FR13

2 x CHK0400

FR14

2
2

4 x CHK0400

2

6 x CHK0400

2

CHK0520

2
2
2
6.50
(165)

6.50
(165)

2

.24
(6)

2

8.03 (204)
1.69
(43)

2

19.57
(497)

1

1

2

.79
(20)

.83
(21)

3

.79
(20)

2

3

3

2

2

2
2
2
2

7.88
(200)

5.70
(145)
9.61 (244)

2

17.57
15.71 (446)
(399)

1.58
(40)

3.03
(77)

2

1

.55 (14)

2

Note
1 Chokes are provided with all FR10–FR14 drives.

2
2
2
Volume 6—Solid-State Motor Control CA08100007E—May 2014 www.eaton.com

V6-T2-85

2.5
2
2

Adjustable Frequency Drives
SVX9000 Drives

Approximate Dimensions in Inches (mm)
CHK0400

2
2

.24
(6)

2
2

4.72
(120)

2

4.72
(120)

9.37 (238)

2

1.54
(39)

13.79 (350)

2

1

1

1

2
2
2

13.94
(354)

2.64
(67)

2

.75
(19)

2

.59
(15)

16.58
15.08 (421)
(383)

1.18
(30)

.59
(15)

3

3

3

2

2

2

5.51
(140)

2

5.90
(150)
10.83 (275)

10.30 (262)

2
2

CHK0261

2
2

.24
(6)

2
4.72
(120)

2

13.79 (350)

2

8.11 (206)
1.54
(39)

2
2

1

2

1

1.18
(30)

.87
(22)

2
2

1

.59
(15)

2
2

4.72
(120)

.59
(15)
.39
(10)

4.25
(108)
9.06 (230)

.75 (19)
Min.

3

3

3

2

2

2

14.06
12.56
11.30 (319) (357)
(287)

5.90
(150)
10.83 (275)

2
V6-T2-86

Volume 6—Solid-State Motor Control CA08100007E—May 2014 www.eaton.com

Adjustable Frequency Drives
SVX9000 Drives

2.5

Contents

SVX9000 Enclosed Drives

Description

Page

SVX9000 Drives . . . . . . . . . . . . . . . . . . . . . . . . . . .
SVX9000 Enclosed Drives
Product Identification . . . . . . . . . . . . . . . . . . . .
Catalog Number Selection . . . . . . . . . . . . . . . .
Product Selection . . . . . . . . . . . . . . . . . . . . . . .
Options . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Technical Data and Specifications . . . . . . . . . .
Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . .
SVX9000 VFD Pump Panels . . . . . . . . . . . . . . . . .

V6-T2-48
V6-T2-88
V6-T2-89
V6-T2-90
V6-T2-94
V6-T2-98
V6-T2-100
V6-T2-111

2
2
2
2
2
2
2
2
2
2
2

SVX9000 Enclosed Drives
Product Description
●

●

Standard Enclosed—
covers a wide range of the
most commonly ordered
options. Pre-engineering
eliminates the lead time
normally associated with
customer specific options.
Modified Standard
Enclosed—applies to
specific customer
requirements that vary
from the standard enclosed
offering, such as the need
for an additional indicating
light or minor modifications
to drawings. Consult your
Eaton representative for
assistance in pricing and
lead time.

Features
●

Custom Engineered—
for those applications with
more unique or complex
requirements, these are
individually engineered to
the customer’s needs.
Consult your Eaton
representative for assistance
in pricing and lead time.

●

●

●

●

●

NEMA Type 1/IP21 or
NEMA Type 12/IP54
enclosures
Input voltage: 208V, 230V,
480V and 575V (consult
factory)
Complete range of control,
network and power options
Horsepower range:
●
208V—3/4 to 100 hp IH;
1 to 100 hp IL
●
230V—3/4 to 100 hp IH;
1 to 100 hp IL
●
480V—1 to 700 hp IH;
1-1/2 to 800 hp IL
Padlockable disconnect

Standards and Certifications
●
●

UL Listed
cUL Listed

2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2

Volume 6—Solid-State Motor Control CA08100007E—May 2014 www.eaton.com

V6-T2-87

2.5

Adjustable Frequency Drives
SVX9000 Drives

2

Product Identification

2

Enclosed 9000X Series Drive
1

2

3

2
2
2

4

2
2

5

2

6

2
2
2

7

2

12

11

10

9

8

2
2
2

1 Door mounted keypad (included as
standard with bypass option)
2 SVX9000 variable frequency drive

6 Output contactor
• Option PE (included as
standard with bypass option)
7 Bypass contactor
• Option RA
• Option RB

3 Input disconnect
• Option P1

2

4 Input line fuses
• Option P3

2

5 Input contactor (included as
standard with bypass option)

8 Overload relay
• Option PH
• Option PI

9 115V control transformer
• Option KB
10 Bypass pilot lights and selector switches
• Option RA
• Option RB
• Option L2
• Option KF
11 Customer control and signal connection
terminal block
12 Control relay

2
2
2
2
2
2
2
2
2
2
2
2
2
V6-T2-88

Volume 6—Solid-State Motor Control CA08100007E—May 2014 www.eaton.com

2.5

Adjustable Frequency Drives
SVX9000 Drives

Catalog Number Selection

2

SVX9000 Enclosed NEMA Type 1/IP21 and NEMA Type 12/IP54 Drives

2

Build Alphabetically and Numerically

SVX F07 1 4 A A

K1
K2

Product Family
SVX = Enclosed drives

F07 = 3/4 hp
001 = 1 hp
F15 = 1-1/2 hp
002 = 2 hp
003 = 3 hp
005 = 5 hp
007 = 7-1/2 hp
010 = 10 hp
015 = 15 hp
020 = 20 hp

Horsepower Rating
025 = 25 hp
030 = 30 hp
040 = 40 hp
050 = 50 hp
060 = 60 hp
075 = 75 hp
100 = 100 hp
125 = 125 hp
150 = 150 hp
200 = 200 hp

_ _ _ _ _ _ _ _ _ _

250 = 250 hp
300 = 300 hp
350 = 350 hp
400 = 400 hp
500 = 500 hp
550 = 550 hp
600 = 600 hp
650 = 650 hp
700 = 700 hp
800 = 800 hp

Enclosure Rating
1 = NEMA Type 1/IP21
2 = NEMA Type 12/IP54
6 = NEMA Type 12/IP54 filtered

Voltage Rating
1 = 208V
2 = 230V
4 = 480V

Application—Torque/Braking 2
A = IL/no brake chopper
B = IL/internal brake chopper
D = IH/no brake chopper
E = IH/internal brake chopper

Enclosed Style
A = Enclosed drive

K4
K5
K6
KB
KF
KO
L1
L2
LA
LD
LE
LF
LJ
LU
P1
P3
P8
PA
PE
PF
PG
PH
PI
PN
RA
RB
RC
RD
S5
S6
S7
S8
S9
SA

C2 =
C3 =
C4 =
C5 =

2

Modbus
PROFIBUS DP
LonWorks
PROFIBUS DP
(D9 connector)

Communication Options 6
C6 = CANopen (slave)
C7 = DeviceNet
C8 = Modbus (D9 type
connector)
CA = Johnson Controls N2

2

Type

Enclosed Options 145
Door-mounted speed potentiometer 3
Door-mounted speed potentiometer with HOA
selector switch 3
HAND/OFF/AUTO switch (22 mm)
MANUAL/AUTO ref switch (22 mm)
START/STOP pushbuttons (22 mm)
115V control transformer (500 VA)
Bypass test switch for RA and RB
Standard elapsed time meter
POWER ON, RUN and FAULT pilot lights
Bypass pilot lights for RA, RB bypass options
Green RUN light (22 mm)
Green STOP light (22 mm)
Red RUN light
Red STOP light (22 mm)
White POWER ON light (22 mm)
Misc. light (22 mm)
Input circuit breaker
Input line fuses (200 kAIC)
SPD (50 kA per phase)
SPD (100 kA per phase)
Output contactor
Output filter (100–300 ft)
MotoRx (300–600 ft) 1000 V/μS DV/DT filter
Single overload relay
Dual overload relays
Dual overloads for bypass
Manual HOA bypass controller
Manual IOB bypass controller
Auto transfer HOA bypass controller
Auto transfer IOB bypass controller
Floor stand 22 in
Floor stand 12 in
10 in expansion
20 in expansion
Space heater
Space heater with CPT

Control
Control

2

Control
Control
Control
Control
Addl. bypass
Control
Light
Addl. bypass
Light
Light
Light
Light
Light
Light
Input
Input
Input
Input
Output
Output
Output
Output
Output
Addl. bypass
Bypass
Bypass
Bypass
Bypass
Enclosure
Enclosure
Enclosure
Enclosure
Enclosure
Enclosure

CI =
CJ =
CQ =
C3 =

2
2
2
2
2
2
2
2
2
2
2
2
2
2

Modbus TCP
BACnet
EtherNet/IP
RS-232 with D9
connection

2
2

Control Options
B1 = 6 DI, 1 ext +24 Vdc/EXT +24 Vdc
B5 = 3 RO (NO)
B2 = 1 RO (NC-NO), 1 RO (NO), 1 therm
B8 = 1 ext +24 Vdc/EXT +24 Vdc, 3 Pt100
B4 = 1 AI (mA isolated), 2 AO (mA isolated), B9 = 1 RO (NO), 5 DI 42–240 Vac input
1 ext +24 Vdc/EXT +24 Vdc
Engineered Options
VB

2
2
2
2

Varnished boards

2

Notes
1 Local/remote keypad is included as the standard control panel.
2 Brake chopper is a factory installed option only, see drive options on Page V6-T2-49. External dynamic braking resistors not included. Consult factory.
3 Includes local/remote speed reference switch.
4 Some options are voltage and/or horsepower specific. Consult your Eaton representative for details.
5 See Pages V6-T2-96 and V6-T2-97 for descriptions.
6 See Pages V6-T2-94 and V6-T2-95 for complete descriptions.

2
2
2
2

Volume 6—Solid-State Motor Control CA08100007E—May 2014 www.eaton.com

V6-T2-89

2.5

Adjustable Frequency Drives
SVX9000 Drives

2

Product Selection

2

2

When Ordering
●
Select a base catalog
number that meets the
application requirements—
nominal horsepower,
voltage and enclosure
rating (the enclosed drive’s
continuous output amp
rating should be equal to or

2

208V Drives

2

SVX9000 Enclosed
Drives

2
2

greater than the motor’s
full load amp rating). The
base enclosed package
includes a standard drive,
door mounted local/remote
keypad and enclosure.

●

If dynamic brake chopper
or control/communication
option is desired, change
the appropriate code in the
base catalog number.

●

Input Base Drives
NEMA Type 1/IP21
Frame
Base Catalog
Current (A) Size
Number 2

2

Enclosure
Size 1

2

High Overload Drive and Enclosure
0

hp

3.7

2

1

4.8

SVX00111EA

SVX00121EA

2

1-1/2

6.6

SVXF1511EA

SVXF1521EA

2

7.8

SVX00211EA

SVX00221EA

3

11

SVX00311EA

5

17.5

7-1/2

25

2

1

10

31

2

15

48

2

20

61

2

5

SVXF0711EA

NEMA Type 12/IP54
Frame
Base Catalog
Size
Number 2

3/4

2

4

SVX00511EA

4

SVX01011EA

SVX00321EA
SVX00521EA

6

SVX01021EA

7

SVX02021DA

SVX00721EA

SVX01511EA
7

SVX02011DA

SVXF0721EA

5

SVX00711EA
6

SVX01521EA

25

75

SVX02511DA

2

30

88

SVX03011DA

3

40

114

8

SVX04011DA

8

SVX04021DA

2

4

50

143

8

SVX05011DA

8

SVX05021DA

5

60

170

8

SVX06011DA

8

SVX06021DA

75

211

9

SVX07511DA

9

SVX07521DA

100

273

2
2

SVX02521DA
SVX03021DA

SVX10011DA

SVX10021DA

Low Overload Drive and Enclosure
0

1

4.8

2

1-1/2

6.6

SVXF1511BA

SVXF1521BA

2

2

7.8

SVX00211BA

SVX00221BA

3

11

SVX00311BA

5

17.5

7-1/2

25

SVX00711BA

10

31

SVX01011BA

15

48

20

61

25

75

30

88

SVX03011AA

2

40

114

SVX04011AA

3

50

—

8

SVX05011AA

8

2

4

60

170

8

SVX06011AA

8

SVX06021AA

5

75 3

205

8

SVX07511AA

8

SVX07521AA

100 3

261

9

SVX10011AA

9

SVX10021AA

2
2

1

2

2

2

2

4

5

6

SVX00111BA

SVX00511BA

SVX01511BA

4

SVX02511AA

SVX00121BA

SVX00321BA
5

SVX00521BA
SVX00721BA
SVX01021BA

6

SVX01521BA

7

SVX02521AA

SVX02011BA
7

SVX02021BA

SVX03021AA
SVX04021AA
SVX05021AA

Notes
For brake chopper options, see Page V6-T2-58.
1 See enclosure dimensions starting on Page V6-T2-100.
2 Includes drive, local/remote keypad and enclosure.
3 These units are current rated (75 I hp 205 amps, 100 I hp 261 amps). They do not meet NEC ampere ratings.
L
L

2
2
V6-T2-90

●

Volume 6—Solid-State Motor Control CA08100007E—May 2014 www.eaton.com

Select enclosed options.
Add the codes as suffixes
to the base catalog number
in alphabetical and numeric
order.
Read all footnotes.

Adjustable Frequency Drives
SVX9000 Drives

2.5

230V Drives
SVX9000 Enclosed
Drives

2

Input Base Drives
NEMA Type 1/IP21
Enclosure
Size 1

hp

Frame
Current (A) Size

2

NEMA Type 12/IP54

Base Catalog
Number 2

Frame
Size

Base Catalog
Number 2

SVXF0712EA

4

SVXF0722EA

2

High Overload Drive and Enclosure
0

1

2

3/4

3.7

1

4.8

SVX00112EA

SVX00122EA

1-1/2

6.6

SVXF1512EA

SVXF1522EA

2

7.8

SVX00212EA

SVX00222EA

3

11

SVX00312EA

SVX00322EA

5

17.5

7-1/2

25

10

31

15

48

20

61

4

5

SVX00512EA

5

SVX00712EA
6

SVX01012EA

SVX02012DA

2
2
2

SVX00522EA
SVX00722EA

6

SVX01512EA
7

2

2

SVX01022EA
SVX01522EA

7

25

75

SVX02512DA

SVX02522DA

30

88

SVX03012DA

SVX03022DA

3

40

114

8

SVX04012DA

8

SVX04022DA

4

50

140

8

SVX05012DA

8

SVX05022DA

5

60

170

8

SVX06012DA

8

SVX06022DA

75

205

9

SVX07512DA

9

100 3

261

SVX10012DA

2

SVX02022DA

2
2
2

SVX07522DA

2

SVX10022DA

2

Low Overload Drive and Enclosure
0

1

4.8

4

1-1/2

6.6

SVXF1512BA

SVXF1522BA

2

7.8

SVX00212BA

SVX00222BA

3

11

SVX00312BA

SVX00322BA

5

17.5

7-1/2

25

5

SVX00112BA

SVX00512BA

4

5

SVX00712BA

SVX00122BA

31
48

20

61

25

75

30

88

SVX03012AA

SVX03022AA

40

114

SVX04012AA

SVX04022AA

3

50

140

8

SVX05012AA

8

SVX05022AA

4

60

170

8

SVX06012AA

8

SVX06022AA

5

75

205

8

SVX07512AA

8

SVX07522AA

100 3

261

9

SVX10012AA

9

SVX10022AA

2

SVX01012BA
SVX01512BA

SVX02512AA

2

SVX01022BA
6

SVX02012BA
7

2

SVX00722BA

10

6

2

SVX00522BA

15

1

2

SVX01522BA

2

SVX02022BA
7

SVX02522AA

2
2
2
2
2

Notes
For brake chopper options, see Page V6-T2-58.
1 See enclosure dimensions starting on Page V6-T2-100.
2 Includes drive, local/remote keypad and enclosure.
3 This unit is current rated (100 I hp 100 amps, 261 I hp). It is not hp rated. They do not meet NEC ampere ratings.
L
L

2
2
2
2
2
2

Volume 6—Solid-State Motor Control CA08100007E—May 2014 www.eaton.com

V6-T2-91

2.5
2
2

Adjustable Frequency Drives
SVX9000 Drives

480V Drives
SVX9000 Enclosed
Drives

Input Base Drives
NEMA Type 1/IP21
Enclosure
Size 1

2

hp

Frame
Current (A) Size

NEMA Type 12/IP54

Base Catalog
Number 2

Frame
Size

Base Catalog
Number 2

SVX00114EA

4

SVX00124EA

High Overload Drive and Enclosure

2

0

1

2.2

2

1-1/2

3.3

SVXF1514EA

SVXF1524EA

2

4.3

SVX00214EA

SVX00224EA

2

3

5.6

SVX00314EA

SVX00324EA

5

7.6

SVX00514EA

SVX00524EA

2

7-1/2

12

2

10

16

SVX01014EA

15

23

SVX01514EA

20

31

1

2
2

2

2
2

3

2

4

2

5

2

6, 8 34

2
2

8, 9 45

2

6

2
2

4

5

6

SVX00714EA

SVX02014EA

25

38

SVX02514EA

30

46

SVX03014EA

40

61

50

72

7

SVX04014DA

5

SVX00724EA
SVX01024EA
SVX01524EA

6

SVX02024EA
SVX02524EA
SVX03024EA

7

SVX05014DA

SVX04024DA
SVX05024DA

60

87

75

105

SVX06014DA

100

140

125

170

8

SVX12514DA

8

SVX12524DA

150

205

9

SVX15014DA

9

SVX15024DA

200

245

250

300

10

SVX25064DA

300

385

8

SVX07514DA

SVX06024DA
8

SVX10014DA

SVX10024DA

SVX20014DA
10

SVX25014DA

SVX07524DA

SVX20024DA

SVX30014DA

SVX30064DA

350

460

400

520

SVX35014DA

500

590

SVX50014DA

550

650

SVX55014DA

600

730

650

820

SVX65014DA

SVX65064DA

700

920

SVX70014DA

SVX70064DA

11

12

SVX40014DA

SVX60014DA

SVX35064DA
11

SVX40064DA
SVX50064DA
SVX55064DA

12

SVX60064DA

Notes
For brake chopper options, see Page V6-T2-58.
1 See enclosure dimensions starting on Page V6-T2-100.
2 Includes drive, local/remote keypad and enclosure.
3 The smaller enclosure Size 6 accommodates only power options, input disconnect (P1) and input line fuses (P3).
Bypass and other options require Size 8. Adding any standard control option will not require the larger enclosure.
4 For other options, consult factory.
5 The smaller enclosure Size 8 accommodates only power options, input disconnect (P1) and input line fuses (P3).
Bypass and other options require Size 9. Adding any standard control option will not require the larger enclosure.
6 Consult factory.

2
2
2
2
2
2
2
2
2
2
V6-T2-92

Volume 6—Solid-State Motor Control CA08100007E—May 2014 www.eaton.com

Adjustable Frequency Drives
SVX9000 Drives

SVX9000 Enclosed
Drives

2.5

Input Base Drives, continued
NEMA Type 12/IP54

2

Base Catalog
Number 2

Frame
Size

Base Catalog
Number 2

2

SVXF1514BA

4

SVXF1524BA

2

NEMA Type 1/IP21
Enclosure
Size 1

hp

Frame
Current (A) Size

Low Overload Drive and Enclosure
0

1

2

1-1/2

3.3

4

2

4.3

SVX00214BA

SVX00224BA

3

5.6

SVX00314BA

SVX00324BA

5

7.6

SVX00514BA

SVX00524BA

7-1/2

12

SVX00714BA

SVX00724BA

10

16

15

23

SVX01514BA

SVX01524BA

20

31

SVX02014BA

SVX02024BA

25

38

30

46

SVX03014BA

SVX03024BA

40

61

SVX04014BA

SVX04024BA

50

72

60

87

5

6

7

SVX01014BA

SVX02514BA

SVX05014AA

5

6

7

SVX06014AA

140

8

SVX10014AA

8

SVX10024AA

4

125

170

8

SVX12514AA

8

SVX12524AA

150

205

200

261

250

300

300

385

350

460

SVX35014AA

SVX35064AA

400

520

SVX40014AA

SVX40064AA

500

590

550

650

SVX55014AA

SVX55064AA

600

730

SVX60014AA

SVX60064AA

650

820

700

920

SVX70014AA

SVX70064AA

800

1030

SVX80014AA

SVX80064AA

8, 9 45

6

SVX07514AA

11

12

SVX50014AA

SVX65014AA

2
2
2

SVX15024AA
9

SVX25014AA
SVX30014AA

2

SVX07524AA

SVX15014AA

10

2

SVX06024AA

105

6, 8 34

2

SVX05024AA

100

SVX20014AA

2

SVX02524BA

75

9

2

SVX01024BA

3

5

2

2

SVX20024AA

2

SVX25024AA
10

11

12

SVX30064AA

2
2

SVX50064AA

2
2

SVX65064AA

2

Notes
For brake chopper options, see Page V6-T2-58.
1 See enclosure dimensions starting on Page V6-T2-100.
2 Includes drive, local/remote keypad and enclosure.
3 The smaller enclosure Size 6 accommodates only power options, input disconnect (P1) and input line fuses (P3).
Bypass and other options require Size 8. Adding any standard control option will not require the larger enclosure.
4 For other options, consult factory.
5 The smaller enclosure Size 8 accommodates only power options, input disconnect (P1) and input line fuses (P3).
Bypass and other options require Size 9. Adding any standard control option will not require the larger enclosure.
6 Consult factory.

2
2
2
2
2
2
2
2
2
2
2

Volume 6—Solid-State Motor Control CA08100007E—May 2014 www.eaton.com

V6-T2-93

2.5
2
2
2
2
2

SVX9000 Drives

Options
9000X Series Option Board Kits
The 9000X Series drives can accommodate a wide selection of expander and adapter option boards
to customize the drive for your application needs. The drive’s control unit is designed to accept a
total of five option boards.
The 9000X Series factory installed standard board configuration includes an A9 I/O board and an A2
relay output board, which are installed in slots A and B.
Option Boards

2

Option Board Kits

Allowed Slot
Locations 2

Field
Installed
Catalog
Number

Factory
Installed
Option
Designator

SVX Ready Programs
Local/
Basic Remote Standard

MSS

PID

Multi-P. PFC

6 DI, 1 DO, 2 AI, 1AO, 1 +10 Vdc ref,
2 ext +24 Vdc/EXT +24 Vdc

A

OPTA9

—

■

■

■

■

■

■

■

2 RO (NC-NO)

B

OPTA2

—

■

■

■

■

■

■

■

Option Kit Description 1

2
2

Adjustable Frequency Drives

Standard I/O Cards
A

D E
B C

2

Extended I/O Cards

2

2 RO, therm—SPX only

B

OPTA3

A3

—

■

■

■

■

■

■

Encoder low volt +5V/15V/24V—SPX only

C

OPTA4

A4

—

■

■

■

■

■

■

2

Encoder high volt +15V/24V—SPX only

C

OPTA5

A5

—

■

■

■

■

■

■

Double encoder—SPX only

C

OPTA7

A7

■

■

■

■

■

■

■

2

6 DI, 1 DO, 2 AI, 1 AO—SPX only

A

OPTA8

A8

—

■

■

■

■

■

■

3 DI (encoder 10–24V), out +15V/+24V,
2 DO (pulse+direction)—SPX only

C

OPTAE

AE

■

■

■

■

■

■

■

6 DI, 1 ext +24 Vdc/EXT +24 Vdc

B, C, D, E

OPTB1

B1

—

—

—

—

—

■

■

1 RO (NC-NO), 1 RO (NO), 1 therm

B, C, D, E

OPTB2

B2

—

—

—

—

—

■

■

1 AI (mA isolated), 2 AO (mA isolated),
1 ext +24 Vdc/EXT +24 Vdc

B, C, D, E

OPTB4

B4

■

■

■

■

■

■

■

3 RO (NO)

B, C, D, E

OPTB5

B5

—

—

—

—

—

■

■

2

1 ext +24 Vdc/EXT +24 Vdc, 3 Pt100

B, C, D, E

OPTB8

B8

—

—

—

—

—

—

—

1 RO (NO), 5 DI 42–240 Vac input

B, C, D, E

OPTB9

B9

—

—

—

—

—

■

■

2

Communication Cards

2
2
2

Modbus 3

D, E

OPTC2

C2

■

■

■

■

■

■

■

2

Modbus TCP

D, E

OPTCI

CI

■

■

■

■

■

■

■

BACnet

D, E

OPTCJ

CJ

2

■

■

■

■

■

■

■

EtherNet/IP

D, E

OPTCQ

CQ

■

■

■

■

■

■

■

Johnson Controls N2 3

D, E

OPTC2

CA

—

—

—

—

—

—

—

2

PROFIBUS DP

D, E

OPTC3

C3

■

■

■

■

■

■

■

2

LonWorks

D, E

OPTC4

C4

■

■

■

■

■

■

■

PROFIBUS DP (D9 connector)

D, E

OPTC5

C5

■

■

■

■

■

■

■

2

CANopen (slave)

D, E

OPTC6

C6

■

■

■

■

■

■

■

DeviceNet

D, E

OPTC7

C7

■

■

■

■

■

■

■

2

Modbus (D9 type connector)

D, E

OPTC8

C8

■

■

■

■

■

■

■

Adapter—SPX only

D, E

OPTD1

D1

■

■

■

■

■

■

■

2

Adapter—SPX only

D, E

OPTD2

D2

■

■

■

■

■

■

■

RS-232 with D9 connection

D, E

OPTD3

D3

■

■

■

■

■

■

■

2

Notes
1 AI = Analog Input; AO = Analog Output, DI = Digital Input, DO = Digital Output, RO = Relay Output
2 Option card must be installed in one of the slots listed for that card. Slot indicated in bold is the preferred location.
3 OPTC2 is a multi-protocol option card.

2
2
2
2
2
V6-T2-94

Volume 6—Solid-State Motor Control CA08100007E—May 2014 www.eaton.com

Adjustable Frequency Drives
SVX9000 Drives

Modbus RTU Network
Communications
The Modbus Network Card
OPTC2 is used for connecting
the 9000X Drive as a slave on
a Modbus network. The
interface is connected by a
9-pin DSUB connector
(female) and the baud rate
ranges from 300 to 19200
baud. Other communication
parameters include an
address range from 1 to 247;
a parity of None, Odd or
Even; and the stop bit is 1.

DeviceNet Network
Communications
The DeviceNet Network Card
OPTC7 is used for connecting
the 9000X Drive on a
DeviceNet Network. It
includes a 5.08 mm pluggable
connector. Transfer method
is via CAN using a two-wire
twisted shielded cable with
two-wire bus power cable
and drain. The baud rates
used for communication
include 125K baud, 250K
baud and 500K baud.

PROFIBUS Network
Communications
The PROFIBUS Network Card
OPTC3 is used for connecting
the 9000X Drive as a slave
on a PROFIBUS-DP network.
The interface is connected
by a 9-pin DSUB connector
(female). The baud rates
range from 9.6K baud to 12M
baud, and the addresses
range from 1 to 127.

Johnson Controls
Metasys N2 Network
Communications
The OPTC2 fieldbus board
provides communication
between the 9000X Drive and
a Johnson Controls
Metasys™ N2 network. With
this connection, the drive can
be controlled, monitored and
programmed from the
Metasys system. The N2
fieldbus is available as a
factory installed option and as
a field installable kit.

LonWorks Network
Communications
The LonWorks Network Card
OPTC4 is used for connecting
the 9000X Drive on a
LonWorks network. This
interface uses Standard
Network Variable Types
(SNVT) as data types. The
channel connection is
achieved using a FTT-10A
Free Topology transceiver
via a single twisted transfer
cable. The communication
speed with LonWorks is
78 kBits/s.
CANopen (Slave)
Communications
The CANopen (Slave)
Network Card OPTC6 is used
for connecting the 9000X
Drive to a host system.
According to ISO11898
standard cables to be chosen
for CAN bus should have a
nominal impedance of 120
ohms, and specific line delay
of nominal 5 nS/m. 120 ohms
line termination resistors
required for installation.

Modbus/TCP Network
Communications
The Modbus/TCP Network
Card OPTCI is used for
connecting the 9000X Drive
to Ethernet networks utilizing
Modbus protocol. It includes
an RJ-45 pluggable connector.
This interface provides a
selection of standard and
custom register values to
communicate drive parameters.
The board supports 10 Mbps
and 100 Mbps communication
speeds. The IP address of the
board is configurable over
Ethernet using a supplied
software tool.

2.5

BACnet Network
Communications
The BACnet Network Card
OPTCJ is used for connecting
the 9000X Drive to BACnet
networks. It includes a
5.08 mm pluggable connector.
Data transfer is Master-Slave/
Token Passing (MS/TP)
RS-485. This interface uses
a collection of 30 Binary Value
Objects (BVOs) and 35 Analog
Value Objects (AVOs) to
communicate drive parameters.
The card supports 9.6, 19.2
and 38.4 Kbaud communication
speeds and supports network
addresses 1–127.

2
2
2
2
2
2
2
2
2

EtherNet/IP Network
Communications
The EtherNet/IP Network
Card OPTCK is used for
connecting the 9000X Drive
to Ethernet/Industrial Protocol
networks. It includes an
RJ-45 pluggable connector.
The interface uses CIP
objects to communicate drive
parameters (CIP is “Common
Industrial Protocol”, the same
protocol used by DeviceNet).
The board supports 10 Mbps
and 100 Mbps communication
speeds. The IP address of the
board is configurable by Static,
BOOTP and DHCP methods.

2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2

Volume 6—Solid-State Motor Control CA08100007E—May 2014 www.eaton.com

V6-T2-95

2.5
2
2
2

Adjustable Frequency Drives
SVX9000 Drives

Control/Communication Option Descriptions
For availability, see Product Selection for base drive voltage required.
Available Control/Communications Options
Option

Description

Option Type

K1

Door-Mounted Speed Potentiometer—Provides the SVX9000 with the ability to adjust the frequency reference using a door-mounted potentiometer. This option uses
the 10 Vdc reference to generate a 0–10V signal at the analog voltage input signal terminal. When the HOA bypass option is added, the speed is controlled when the
HOA switch is in the HAND position. Without the HOA bypass option, a two-position switch (labeled local/remote) is provided on the keypad to select speed reference from the
speed potentiometer or a remote speed signal.

Control

K2

Door-Mounted Speed Potentiometer with HOA Selector Switch—Provides the SVX9000 with the ability to start/stop and adjust the speed reference from
door-mounted control devices or remotely from customer supplied inputs. In HAND position, the drive will start and the speed is controlled by the door-mounted speed
potentiometer. The drive will be disabled in the OFF position. When AUTO is selected, the drive run and speed control commands are via user-supplied dry contact and
4–20 mA signal.

Control

K4

HAND/OFF/AUTO Switch for Non-Bypass Configurations—Provides a three-position selector switch that allows the user to select either a HAND or AUTO mode of
operation. HAND mode is defaulted to k (keypad operation, and AUTO mode is defaulted to control from an external terminal source. These modes of operation can be
configured via programming to allow for alternate combinations of start and speed sources. Start and speed sources include keypad, I/O and fieldbus.

Control

K5

MANUAL/AUTO Speed Reference Switch—Provides a door-mounted selector switch for MANUAL/AUTO speed reference.

Control

2

K6

START/STOP Pushbuttons—Provide door-mounted START and STOP pushbuttons for either bypass or non-bypass configurations.

Control

2

KB

115V Control Transformer, 500 VA—Provides a fused control power transformer with additional 500 VA at 115V for customer use.

Control

KF

Bypass Test Switch for RB and RA—Allows the user to energize the AF drive for testing while operating the motor on the bypass controller. The test switch is
mounted on the inside of the enclosure door.

Addl. bypass

KO

Standard Elapsed Time Meter—Provides a door-mounted elapsed run time meter.

Control

L1

POWER ON, RUN and FAULT Pilot Lights —Provide a white POWER ON light that indicates power to the enclosed cabinet, a green RUN light that indicates the drive
is running and a red FAULT light that indicates a drive fault has occurred.

Light

L2

Bypass Pilot Lights for RA and RB Bypass Options—A green MOTOR ON INVERTER light indicates when the motor is running in inverter mode and an amber
MOTOR ON BYPASS light indicates when the motor is running in bypass mode. The lights are mounted on the enclosure door, above the switches.

Addl. bypass

2
2
2
2
2

2
2
2
2

LA

Green RUN Light (22 mm)—Provides a green RUN light that indicates the drive is running.

Light

LD

Green STOP Light (22 mm)—Provides a green STOP light that indicates the drive is stopped.

Light

2

LE

Red RUN Pilot Light (22 mm)—Provides a red RUN pilot light that indicates the drive is running.

Light

LF

Red STOP Light (22 mm)—Provides a red STOP light that indicates the drive is stopped.

Light

2

LJ

White POWER ON Light (22 mm)—Provides a white POWER ON light that indicates power to the enclosed cabinet.

Light

LU

Misc. Light (22 mm)—Provides a misc. “user defined” pilot light. User to define light function and color.

Light

P1

Input

2

Input Circuit Breaker—Provides a means of short-circuit protection for the power cables between it and the SVX9000, and protection from high-level ground faults on
the power cable. Allows a convenient means of disconnecting the SVX9000 from the line and the operating mechanism can be padlocked in the OFF position. This is factory
mounted in the enclosure.

P3

Input

2

Input Line Fuses Rated to 200 kAIC—Provides high-level fault protection of the SVX9000 input power circuit from the load side of the fuses to the input side of the
power transistors. This option consists of three 200 kA fuses, which are factory mounted in the enclosure.

P8

Input

2

SPD (50 kA per Phase)—Provides a surge protection device (SPD) connected to the line side terminals and is designed to clip line side transients.
Rated for 50,000A.

PA

Input

2

SPD (100 kA per Phase)—Provides a surge protection device (SPD) connected to the line side terminals and is designed to clip line side transients.
Rated for 100,000A.

PE

Output Contactor—Provides a means for positive disconnection of the drive output from the motor terminals. The contactor coil is controlled by the drive’s run or
permissive logic. NC and NO auxiliary contacts rated at 10A, 600 Vac are provided for customer use. Bypass options RB and RA include an output contactor as standard.
This option includes a low VA 115 Vac fused control power transformer and is factory mounted in the enclosure.

Output

PF

Output Filter (100–300 ft)—Used to reduce the transient voltage (DV/DT) at the motor terminals. The output filter is recommended for cable lengths exceeding 100 ft
(30m) with a drive of 3 hp and above, for cable lengths of 33 ft (10m) with a drive of 2 hp and below, or for a drive rated at 525–690V. This option is mounted in the enclosure,
and may be used in conjunction with a brake chopper circuit.

Output

PG

MotoRX (300–600 ft) 1000 V/μS DV/DT Filter—Used to reduce transient voltage (DV/DT) and peak voltages at the motor terminals. This option is comprised of a 0.5%
line reactor, followed by capacitive filtering and an energy recovery/clamping circuit. Unlike the output filter (See option PF), the MotoRx recovers most of the energy from the
voltage peaks, resulting in a lower voltage drop to the motor, and therefore conserving power. This option is used when the distance between a single motor and the drive
is 300–600 ft (91–183m). This option can not be used with the brake chopper circuit. The output filter (option PF) should be investigated as an alternative.

Output

PH

Single Overload Relay—Uses a bimetallic overload relay to provide additional overload current protection to the motor on configurations without bypass options. It is
included with the bypass configurations for overload current protection in the bypass mode. The overload relay is mounted within the enclosure, and is manually
resettable. Heater pack included.

Output

PI

Dual Overload Relays—This option is recommended when a single drive is operating two motors and overload current protection is needed for each of the motors. The
standard configuration includes two bimetallic overload relays, each sized to protect a motor with 50% of the drive hp rating. For example, a 100 hp drive would include
two overload relays sized to protect two 50 hp motors. The relays are mounted within the enclosure, and are manually resettable. Heater packs not included.

Output

PN

Dual Overloads for Bypass—This option is recommended when a single drive is operating two motors in the bypass mode and overload current protection is needed
for each of the motors. The standard configuration includes two bimetallic overload relays, each sized to protect a motor with 50% of the drive hp rating. For example, a
100 hp drive would include two overload relays sized to protect two 50 hp motors. The relays are mounted within the enclosure, and are manually resettable.

Addl. bypass

2

2
2
2
2
2
2
2
2
2

V6-T2-96

Volume 6—Solid-State Motor Control CA08100007E—May 2014 www.eaton.com

Adjustable Frequency Drives
SVX9000 Drives

2.5

For availability, see Product Selection for base drive voltage required.

2

Available Control/Communications Options, continued
Option

Description

Option Type

RA

Manual HOA Bypass Controller—The manual HAND/OFF/AUTO (HOA)—3-contactor—bypass option provides a means of bypassing the SVX9000, allowing the AC
motor to be operated at full speed directly from the AC supply line. This option consists of an input disconnect, a fused control power transformer, and a full voltage
bypass starter with a door mounted HOA selector switch and an INVERTER/BYPASS switch. The HOA switch provides the ability to start and stop the drive in the inverter
mode. For applications up to 100 hp, a Freedom Series IEC input contactor, a Freedom Series IEC output contactor, and a Freedom Series IEC starter with a bimetallic
overload relay is included. For applications above 100 hp, an Advantage input contactor, an Advantage output contactor and an Advantage starter with electronic
overload protection is included. The contactors are mechanically and electrically interlocked.

Bypass

Manual IOB Bypass Controller—The manual INVERTER/OFF/BYPASS (IOB)—3-contactor—bypass option provides a means of bypassing the SVX9000, allowing
the AC motor to be operated at full speed directly from the AC supply line. This option consists of an input disconnect, a fused control power transformer, and a full
voltage bypass starter with a door mounted IOB selector switch. For applications up to 100 hp, a Freedom Series IEC input contactor, a Freedom Series IEC output
contactor, and a Freedom Series IEC starter with a bimetallic overload relay is included. For applications above 100 hp, an Advantage input contactor, an Advantage
output contactor and an Advantage starter with electronic overload protection is included. The contactors are mechanically and electrically interlocked.

Bypass

Auto Transfer HOA Bypass Controller—The manual HAND/OFF/AUTO (HOA)—3-contactor—bypass option provides a means of bypassing the SVX9000, allowing
the AC motor to be operated at full speed directly from the AC supply line. The circuitry provides an automatic transfer of the load to “across the line” operation after a
drive trip. This option consists of an input disconnect, a fused control power transformer, and a full voltage bypass starter with a door mounted HOA selector switch and
an INVERTER/BYPASS switch. The HOA switch provides the ability to start and stop the drive in either mode. For applications up to 100 hp, a Freedom Series IEC input
contactor, a Freedom Series IEC output contactor, and a Freedom Series IEC starter with a bimetallic overload relay is included. For applications above 100 hp, an Advantage input
contactor, an Advantage output contactor and an Advantage starter with electronic overload protection is included. The contactors are mechanically and electrically
interlocked. Door-mounted pilot lights are provided which indicate bypass or inverter operation. A green light indicates when the motor is running in inverter mode and an
amber light indicates when the motor is running in bypass mode.
WARNING: The motor may restart when the overcurrent relay is reset when operating in bypass, unless the IOB selector switch is turned to the OFF position.

Bypass

Auto Transfer IOB Bypass Controller—The auto INVERTER/OFF/BYPASS (IOB)—3-contactor—bypass option provides a means of bypassing the SVX9000, allowing
the AC motor to be operated at full speed directly from the AC supply line. The circuitry provides an automatic transfer of the load to “across the line” operation after a
drive trip. This option consists of an input disconnect, a fused control power transformer, and a full voltage bypass starter with a door mounted IOB selector switch. For
applications up to 100 hp, a Freedom Series IEC input contactor, a Freedom Series IEC output contactor, and a Freedom Series IEC starter with a bimetallic overload relay
is included. For applications above 100 hp, an Advantage input contactor, an Advantage output contactor and an Advantage starter with electronic overload protection is
included. The contactors are mechanically and electrically interlocked. Door-mounted pilot lights are provided which indicate bypass or inverter operation. A green light
indicates when the motor is running in inverter mode and an amber light indicates when the motor is running in bypass mode.
WARNING: The motor may restart when the overcurrent relay is reset when operating in bypass, unless the IOB selector switch is turned to the OFF position.

Bypass

RB

RC

RD

2
2
2
2
2
2
2
2
2
2
2
2
2

S5

Floor Stand 22 in—Converts a Size 1 or 2, normally wall mounted enclosure to a floor standing enclosure with a height of 22 in (558.8 mm).

Enclosure

S6

Floor Stand 12 in—Converts a Size 2, normally wall mounted enclosure to a floor standing enclosure with a height of 12 in (304.8 mm).

Enclosure

S7

10 in Expansion—In a Size 5 enclosure, the extension allows for bottom cable entry and additional space for customer mounted components.
NOTE: Enclosure expansion rated NEMA Type 1/IP21 only.

Enclosure

2

S8

20 in Expansion—In a Size 5 enclosure, the extension allows for bottom cable entry and additional space for customer mounted components. When the output filter
(option PF) is selected for a drive using a Size 5 enclosure, this expansion box is required and included in the option pricing.
Enclosure expansion rated NEMA Type 1/IP21 only.

Enclosure

2

S9

Space Heater—Prevents condensation from forming in the enclosure when the drive is inactive or in storage. Includes a thermostat for variable temperature control. A
200W heater is installed in enclosures 0 and 1, and a 400W heater is installed in enclosures 2–5.

Enclosure

SA

Space Heater with CPT—Prevents condensation from forming in the enclosure when the drive is inactive or in storage. Includes a thermostat for variable temperature
control. A 200W heater is installed in enclosures 0 and 1, and a 400W heater is installed in enclosures 2–5. Includes a 115V supply to power heater.

Enclosure

SVX Conversion Kit

Brake Chopper Options

Frame 4–7

The brake chopper circuit option is used for applications that
require dynamic braking. Dynamic braking resistors are not
included with drive purchase. Consult Page V6-T2-58 for
dynamic braking resistors which are supplied separately.
Resistors are not UL Listed.

Frame
Size

Enclosure
Size

Delivery
Code

Catalog Number

FR4

0

FB10

OPTCON-SVXFR4-SZ00

1

For brake chopper circuit selection and adder—NEMA
Type 1/IP21, NEMA Type 12/IP54, consult the factory

1

FB10

2

2

OPTCON-SVXFR5-SZ00

2

OPTCON-SVXFR5-SZ01
FB10

2
FR7

2

OPTCON-SVXFR4-SZ01

1
FR6

2
2

1

0

2
2

Enclosed Drive Options

FR5

2

2

OPTCON-SVXFR6-SZ01
OPTCON-SVXFR6-SZ02

FB10

2

OPTCON-SVXFR7-SZ02

Note
1 The kit consists of a flange kit, adapter plate(s), hardware, remote keypad kit and
SVX9000 decal.

2
2
2
2

Volume 6—Solid-State Motor Control CA08100007E—May 2014 www.eaton.com

V6-T2-97

2.5

Adjustable Frequency Drives
SVX9000 Drives

2

Technical Data and Specifications

2

9000X Enclosed Drives

2

Description

NEMA Type 1/IP21 or NEMA Type 12/IP54
Specification

Primary Design Features

Description

NEMA Type 1/IP21 or NEMA Type 12/IP54
Specification

Input/Output Interface Features

2

45–66 Hz input frequency

Standard

2

Output: AC volts maximum

Input voltage base

Output frequency range

0–320 Hz

2

Initial output current (IH)

250% for 2 seconds

Overload (1 minute [IH/IL])

150%/110%

Drive mounted keypad/display

2

Enclosure space heater

Optional

Remote keypad/display

Standard

Oversize enclosure

Standard

Conventional control elements

Standard

2

Output contactor

Optional

Serial communications

Optional

2

Bypass motor starter

Optional

115 Vac control circuit

Optional

Listings

UL, cUL

Setup adjustment provisions
Remote keypad/display

Standard

Personal computer

Standard

Operator control provisions
Standard

Speed setting inputs

2

Protection Features
Incoming line fuses

Optional

0–10 Vdc potentiometer/voltage signal

Standard

2

AC input circuit disconnect

Optional

4–20 mA Isolated

Configurable

2

Line reactors (3%)

Standard

4–20 mA Differential

Configurable

Phase rotation insensitive

Standard

2

EMI filter

Standard

Speed/frequency

Input phase loss protection

Standard

Torque/load/current

Programmable

2

Input overvoltage protection

Standard

Motor voltage

Programmable

Line surge protection

Optional

Kilowatts

Programmable

2

Output short-circuit protection

Standard

0–10 Vdc signals

Configurable w/jumpers

2

Output ground fault protection

Standard

4–20 mA DC signals

Standard

Output phase protection

Standard

Isolated signals

Optional

2

Overtemperature protection

Standard

Discrete outputs

DC overvoltage protection

Standard

Fault alarm

Standard

2

Drive overload protection

Standard

Drive running

Standard

Motor overload protection

Standard

Drive at set speed

Programmable

2

Programmer software

Optional

Optional parameters

14

2

Local/remote keypad

Standard

Dry contacts

1 (2 relays Form C)

Keypad lockout

Standard

Open collector outputs

1

Fault alarm output

Standard

Additional discrete outputs

Optional

Built-in diagnostics

Standard

2

Keypad

Standard

Analog outputs
Standard

Communications

2

RS-232

Standard

2

RS-422/485

Optional

DeviceNet™

Optional

2

Modbus RTU

Optional

CANopen (slave)

Optional

2

PROFIBUS-DP

Optional

Lonworks®

Optional

2

Johnson Controls Metasys™ N2

Optional

2

EtherNet/IP

Optional

Modbus TCP

Optional

BACnet

Optional

2
2
2
V6-T2-98

Volume 6—Solid-State Motor Control CA08100007E—May 2014 www.eaton.com

Adjustable Frequency Drives
SVX9000 Drives

9000X Enclosed Drives, continued

2.5

Standard I/O Specifications

2

NEMA Type 1/IP21 or NEMA Type 12/IP54
Specification

Description

Specification

Six–digital input
programmable

24V: “0” <10V, “1” >18V,Ri >5 kohms

2

Sensorless vector control

Standard

Volts/hertz control

Standard

Two–analog input
configurable w/jumpers

Voltage: 0–±10V, Ri >200 kohms
Current: 0 (4)–20 mA, Ri = 250 ohms

2

IR and slip compensation

Standard

Two–digital output
programmable

Form C relays 250 Vac
30 Vdc 2 amp resistive

2

Electronic reversing

Standard
Optional 1

2

DC braking

Standard

One–analog output
programmable
configurable w/jumper

0–20 mA, RL max. 500 ohms 10 bits ±2%

Dynamic braking

PID setpoint controller

Programmable

One digital output
programmable

Open collector 48 Vdc 50 mA

Critical speed lockout

Standard

Current (torque) limit

Standard

Adjustable acceleration/deceleration

Standard

I/O Specifications for Control/Communication Options

Linear or S curve accel/decel

Standard

Description

Specification

Jog at preset speed

Standard

Analog voltage, input

0–±10V, Ri >200 kohms

Thread/preset speeds

7 Standard, 15 Optional

Analog current, input

0 (4)–20 mA, Ri = 250 ohms

Automatic restart

Selectable

Digital input

24V: “0” <10V, “1” >18V, Ri >5 kohms

Coasting motor start

Standard

Auxiliary voltage

24V (±20%), max. 50 mA

Coast or ramp stop selection

Standard

Reference voltage

10V ±3%, max. 10 mA

Elapsed time meter

Optional

Analog current, output

Carrier frequency adjustment

1–16 kHz

0 (4)–20 mA, RL = 500 kohms resolution 10 bit,
accuracy <±2%

Analog voltage, output

0 (2)–10V, RL >1 kohms, resolution 10 bit,
accuracy <±2%

Description
Performance Features

Standard Conditions for Application and Service

2
2
2
2
2
2
2
2
2

Operating ambient temperature

0 to 40°C

Storage temperature

–40 to 60°C

Maximum switching voltage

Humidity (maximum), non-condensing

95%

Maximum switching load

8A/24 Vdc, 0.4A/300 Vdc, 2 kVA/250 Vac

Altitude (maximum without derate)

3300 ft (1000m)

Maximum continuous load

2A rms

Line voltage variation

+10/–15%

Thermistor input

Rtrip = 4.7 kohms

2

Line frequency variation

45–66 Hz

Encoder input

Efficiency

>96%

24V: “0” <10V, “1” >18V, Ri = 2.2 kohms
5V: “0” <2V, “1” >3V, Ri = 330 ohms

2

Power factor (displacement)

>0.94

Relay output
300 Vdc, 250 Vac

Note
1 Some horsepower units include dynamic braking chopper as standard—refer to individual
drive sections.

2

2
2
2
2
2
2
2
2
2
2
2
2
2

Volume 6—Solid-State Motor Control CA08100007E—May 2014 www.eaton.com

V6-T2-99

2.5
2

Adjustable Frequency Drives
SVX9000 Drives

Dimensions
Approximate Dimensions in Inches (mm)

2

9000X Enclosed Drives

2

Size 0
1.50 (38.1)
Lifting Holes
4 Places

2

K

For Cable
Entry

K

V

J

2

U

2
2

L
H

B

S

F

T
Top View

2
2

C

2

P

D
A
0.44 (11.2)
Mounting Holes
4 Places

2

W
V

NEMA Type 1/IP21, NEMA Type 12/IP54
NEMA Type 12/IP54 Includes Cover Plates Over Louvers

2
2

For Cable
Entry

R

Bottom View

For reference only, dimensions are subject to change.
Wide

High

Deep

Mounting

Door Height

Min. Air Space

A

B

C

D

D1

E

E1

F

G

G1

H

J

K

2

19.9 (504)

29.0 (737)

16.4 (416)

18.3 (465)

—

—

—

27.4 (695)

—

—

25.4 (644)

4.0 (102)

3.0 (76)

2

Cable Entry
L

M

N

P

R

Door Clearance
S

CB Handle
T

U

V

W

Max. Approx.
Shipping Weight
Lbs (kg)

2

5.0 (127)

—

—

6.0 (152)

9.6 (245)

26.4 (669)

1.5 (38)

6.3 (160)

4.3 (108)

5.3 (134)

200 (91)

2

2
2
2
2
2
2
2
2
2
2
2
2
2
V6-T2-100

Volume 6—Solid-State Motor Control CA08100007E—May 2014 www.eaton.com

2.5

Adjustable Frequency Drives
SVX9000 Drives

Approximate Dimensions in Inches (mm)

2

Size 1
2.50 (63.5)
Lifting Holes
4 Places

2.50 (63.5)
Lifting Holes
4 Places

K
J

2

D
K

AA

2

J

2
H

B

2

H

B

F

2

C

2

CC

X
D
A
0.44 (11.2)
Mounting Holes
4 Places

2

BB

2
2

NEMA Type 1/IP21, NEMA Type 12/IP54
NEMA Type 12/IP54 Includes Cover Plates Over Louvers
Y

2

DD
A

Z
C

2

NEMA Type 1/IP21, NEMA Type 12/IP54
with Floor Stand

M

For Cable
Entry

N

0.44 (11.2)
Mounting Holes
6 Places
For Cable
Entry

For Cable
Entry

L
For Cable
Entry

P

FF

For Cable
Entry

2

MM

2

KK

R

T
Top View

2

NN

EE
EE

U

S

2

2

U

JJ

GG
HH

Bottom View

LL

2

Bottom View
NEMA Type 1/IP21, NEMA Type 12/IP54
with Floor Stand

2

For reference only, dimensions are subject to change.

2

Wide

High

Deep

Mounting

Door Height

Min. Air Space

A

B

C

D

D1

E

E1

F

G

G1

H

J

K

26.4 (669)

36 (914)

16.3 (414)

24.8 (630)

—

—

—

34.0 (864)

—

—

32.4 (822)

4.0 (102)

3.0 (76)

CB Handle
T

U

V

W

Max. Approx.
Shipping Weight
Lbs (kg)

1.5 (38)

4.3 (108)

—

—

230 (104)

Cable Entry
L

M

N

P

R

Door Clearance
S

11.0 (279)

6.0 (152)

9.0 (229)

10.0 (254)

6.5 (165)

26.4 (669)

2
2
2
2

Floor Stand
X

Y

Z

AA

BB

CC

DD

EE

FF

GG

HH

JJ

KK

LL

MM

NN

PP

RR

SS

TT

UU

VV

56.0
(1422)

4.3
(108)

11.1
(281)

1.8
(46)

0.8
(19)

55.2
(1402)

26.0
(660)

3.5
(90)

5.5
(141)

3.0
(76)

6.0
(152)

2.0
(51)

5.4
(136)

1.1
(28)

8.8
(224)

5.4
(137)

—

—

—

—

—

—

2
2
2
2
2
2

Volume 6—Solid-State Motor Control CA08100007E—May 2014 www.eaton.com

V6-T2-101

2.5
2
2

Adjustable Frequency Drives
SVX9000 Drives

Approximate Dimensions in Inches (mm)
Size 2
2.50 (63.5)
Lifting Holes
2 Places

2

2.50 (63.5)
Lifting Holes AA
2 Places

J

D
J

K

2

K

2.50 (63.5)
Lifting Holes AA
2 Places

D
J

2
2
2

K

H

B

H

B

F

PP

NN

2

H

XB

CC

2
2

C

D
A
0.44 (11.2)
Mounting Holes
4 Places
NEMA Type 1/IP21, NEMA Type 12/IP54
NEMA Type 12/IP54 Includes
Cover Plates Over Louvers

2
2
2

BB

BB

Z
DD
C
A
NEMA Type 1/IP21, NEMA Type 12/IP54
with 22 in Floor Stand
Y

2
2

For Cable
Entry

For Cable
Entry

2

Y

Z
DD
C
A
NEMA Type 1/IP21, NEMA Type 12/IP54
with 12 in Floor Stand

For Cable
Entry

0.44 (11.2) Mounting
Holes 6 Places

EE
EE

P
FF

2

For Cable
Entry
MM

L
U

S

2

V

U

R
Bottom View

T
Top View

JJ

GG
HH

2

LL

KK

Bottom View
NEMA Type 1/IP21, NEMA Type 12/IP54
with Floor Stand

2

For reference only, dimensions are subject to change.

2

Wide

High

Deep

Mounting

Door Height

Min. Air Space

A

B

C

D

D1

E

E1

F

G

G1

H

J

K

26.4 (669)

59.0 (1499)

19.4 (492)

24.8 (630)

—

—

—

57.0 (1448)

—

—

55.4 (1406)

4.0 (102)

3.0 (76)

CB Handle
T

U

V

W

Max. Approx.
Shipping Weight
Lbs (kg)

1.5 (38)

4.8 (121)

5.9 (151)

—

380 (173)

2
2
2
2
2
2

Cable Entry
L

M

N

P

R

Door Clearance
S

5.9 (149)

—

—

12.4 (315)

9.5 (241)

26.4 (669)

Floor Stand
X

Y

Z

AA

BB

CC

DD

EE

FF

GG

HH

JJ

KK

LL

MM

NN

PP

RR

SS

TT

UU

VV

69.0
(1753)

4.8
(121)

13.6
(344)

1.8
(46)

0.8
(19)

68.2
(1732)

26.0
(660)

4.8
(121)

6.8
(172)

3.0
(76)

6.0
(152)

2.0
(51)

5.0
(127)

1.1
(28)

11.3
(288)

79.0
(2007)

78.2
—
(1986)

—

—

—

—

2
2
2
V6-T2-102

Volume 6—Solid-State Motor Control CA08100007E—May 2014 www.eaton.com

2.5

Adjustable Frequency Drives
SVX9000 Drives

Approximate Dimensions in Inches (mm)

2

Size 3

2

0.50 (12.7)
Lifting Eyes
2 Places

2

K

J

M

P

2

V
For Cable
Entry

2

U
L

2

S
T

2

Top View
H
B

RR

0.44 (11.2)
Mounting Holes
6 Places
R

2
2

For Cable
Entry

2

N

F

2

G
TT
UU

SS
C

G1 D1
E1

A

NEMA Type 1/IP21, NEMA Type 12/IP54
NEMA Type 12/IP54 Includes Cover Plates Over Louvers

2

W

D
E
VV
Bottom View

2
2

For reference only, dimensions are subject to change.
Wide

High

Deep

Mounting

Door Height

Min. Air Space

A

B

C

D

D1

E

E1

F

G

G1

H

J

K

26.4 (671)

77.0 (1956)

19.4 (493)

19.5 (495)

3.3 (83)

23.0 (584)

1.5 (38)

11.7 (298)

5.5 (140)

0.9 (24)

76.4 (1939)

4.0 (102)

3.0 (76)

Cable Entry

Door Clearance

CB Handle

L

M

N

P

R

S

T

U

V

W

RR

SS

TT

UU

VV

5.3
(133)

23.4
(594)

10.0
(254)

1.3
(32)

12.9
(328)

26.4
(669)

1.5
(38)

8.0
(203)

4.8
(121)

6.8
(173)

79.5
(2018)

13.40
(340)

0.8
(19)

1.3
(32)

26.0
(660)

Max. Approx.
Shipping Weight
Lbs (kg)
690 (313)

2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2

Volume 6—Solid-State Motor Control CA08100007E—May 2014 www.eaton.com

V6-T2-103

2.5
2
2

Adjustable Frequency Drives
SVX9000 Drives

Approximate Dimensions in Inches (mm)
Size 4
0.50 (12.7)
Lifting Eyes
2 Places

2

J

K
M

2

V

2

For Cable
Entry

2

U
L
S

2
2

T
Top View

H
B

RR
0.44 (11.2)
Mounting Holes
6 Places
R

2
2
SS
TT
C

2

2
2
2
2

N

G

2

2

For Cable
Entry

F

2

2

P

G1 D1
E1

A

D
E

NEMA Type 1/IP21, NEMA Type 12/IP54
NEMA Type 12/IP54 Includes Cover Plates Over Louvers

Bottom View

For reference only, dimensions are subject to change.
Wide

High

Deep

Mounting

Door Height

Min. Air Space

A

B

C

D

D1

E

E1

F

G

G1

H

J

K

26.4 (671)

90.0 (2286)

19.4 (493)

19.5 (495)

3.3 (83)

23.0 (584)

1.5 (38)

11.7 (298)

5.5 (140)

0.9 (24)

89.4 (2270)

4.0 (102)

3.0 (76)

L

M

N

P

R

S

T

U

V

W

RR

SS

TT

UU

VV

Max. Approx.
Shipping Weight
Lbs (kg)

5.3
(133)

23.4
(594)

13.8
(351)

1.0
(25)

11.2
(286)

26.4
(669)

1.5
(38)

8.0
(204)

4.8
(121)

—

92.5
(2349)

0.8
(19)

1.3
(32)

—

—

825 (375)

Cable Entry

Door Clearance

CB Handle

2
2
2
2
2
2
2
2
2
2
2
V6-T2-104

Volume 6—Solid-State Motor Control CA08100007E—May 2014 www.eaton.com

2.5

Adjustable Frequency Drives
SVX9000 Drives

Approximate Dimensions in Inches (mm)

2

Size 5

2

J

2
2
2

Lifting Eyes
(2 Places)

2
2

RR

2
For Cable
Entry

T

N

2

L

2

H
S

M

B

2

P

Top View

A
Front View
NEMA Type 1/IP21

2
2

0.56 (14.2) Dia.
Mounting
Holes
(4 Places)

2

F

2

SS
G
C

2

D

D1

Side View

Bottom View

2
2

IL hp
208/230V

  75
100

2

480V

200
250

2
2
2

Front View
NEMA Type 12/IP54

2

For reference only, dimensions are subject to change.
Wide

High

Deep

Mounting

Door Height

Min. Air Space

A

B

C

D

D1

E

E1

F

G

G1

H

J

K

40.0 (1016)

90.0 (2286)

21.3 (541)

36.0 (914)

2.0 (51)

—

—

8.0 (203)

10.8 (273)

—

84.4 (2143)

4.0 (102)

—

L

M

N

P

R

S

T

U

V

W

RR

SS

TT

UU

VV

Max. Approx.
Shipping Weight
Lbs (kg)

15.0
(381)

10.0
(254)

4.8
(122)

2.0
(51)

—

36.3
(921)

20.0
(508)

—

—

—

94.0
(2387)

15.5
(394)

—

—

—

1275 (579)

Cable Entry

Door Clearance

2
2
2
2
2
2
2

Volume 6—Solid-State Motor Control CA08100007E—May 2014 www.eaton.com

V6-T2-105

2.5
2
2

Adjustable Frequency Drives
SVX9000 Drives

Approximate Dimensions in Inches (mm)
Size 5-1P
J

2
2
2
2

Lifting Eyes
(2 Places)

2

RR
For Cable
Entry

2
2

L

T

2
2

S

H

B

Door Clearance

P

M

Top View

A

2

N

Front View
NEMA Type 1/IP21

0.56 (14.2) Dia.
Mounting Holes
(4 Places)

2
2

F

2

G
SS
C

V

U

D

D1

2

For Cable
Entry

P

M
Bottom View

2
2

IL hp

2

208/230V

  75
100

2

480V

200
250

2
2

Front View
NEMA Type 12/IP54

2

For reference only, dimensions are subject to change.

2

Wide

High

Deep

Mounting

Door Height

Min. Air Space

A

B

C

D

D1

E

E1

F

G

G1

H

J

K

2

50.0 (1270)

90.0 (2286)

21.3 (541)

36.0 (914)

2.0 (51)

—

—

8.0 (203)

10.8 (273)

—

84.4 (2143)

4.0 (102)

—

2
2
2

L

M

N

P

R

S

T

U

V

W

RR

SS

TT

UU

VV

Max. Approx.
Shipping Weight
Lbs (kg)

17.1
(435)

8.0
(203)

1.3
(33)

1.0
(25)

—

36.3
(921)

20.0
(508)

18.4
(466)

1.3
(32)

—

94.0
(2387)

15.5
(394)

—

—

—

1375 (624)

Cable Entry

Door Clearance

2
2
V6-T2-106

Volume 6—Solid-State Motor Control CA08100007E—May 2014 www.eaton.com

2.5

Adjustable Frequency Drives
SVX9000 Drives

Approximate Dimensions in Inches (mm)

2

Size 5-2P

2

J

2
2
2

Lifting Eyes
(2 Places)

2
RR

2

For Cable
Entry

T

2

L

S

H

B

2

N

M

Door Clearance

P

Top View

A
Front View
NEMA Type 1/IP21

0.56 (14.2) Dia.
Mounting Holes
(4 Places)

2

F
V

SS
C

U

2
2

D

D1

2
2

For Cable
Entry

G

2

R

M
Bottom View

2
2

IL hp

2

208/230V

  75
100

2

480V

200
250

2
2
2

Front View
NEMA Type 12/IP54

2

For reference only, dimensions are subject to change.
Wide

High

Deep

Mounting

Door Height

Min. Air Space

A

B

C

D

D1

E

E1

F

G

G1

H

J

K

21.3 (541)

36.0 (914)

2.0 (51)

—

—

8.0 (203)

10.8 (273)

—

84.4 (2143)

4.0 (102)

—

2

Enclosure Size 5-2P
60.0 (1524)

90.0 (2286)

2

L

M

N

P

R

S

T

U

V

W

RR

SS

TT

UU

VV

Max. Approx.
Shipping Weight
Lbs (kg)

17.0
(432)

18.0
(457)

1.5
(38)

1.0
(25)

0.9
(23)

36.3
(921)

20.0
(508)

18.4
(466)

1.3
(32)

—

94.0
(2387)

15.5
(394)

—

—

—

1585 (720)

Cable Entry

Door Clearance

2
2
2
2
2

Volume 6—Solid-State Motor Control CA08100007E—May 2014 www.eaton.com

V6-T2-107

2.5
2
2

Adjustable Frequency Drives
SVX9000 Drives

Approximate Dimensions in Inches (mm)
Size 6

2

T

2
2

S

Door Clearance
Top View

2
2

J

2

Keypad

2

Flanged Disconnect Supplied
with Circuit Breaker When Specified

2

Operator Elements When Specified,
Mounted on These Panels

2
2

RR

B

Key-Locking Handle

H

2
2
2

Ventilating Slots

2

Quarter Turn Latch
(2 Places)

2

C

2

A

Side View

Front View

2
480V

2

For Cable Entry

N

IL hp

2

F

300
350
400

P

0.56 (14.2) Dia.
Mounting Hole –
(4 Places)

G

2
2

L

M

D1

D
Bottom View

For reference only, dimensions are subject to change. See Page V6-T2-92, notes 3 and 5 for enclosure and option selection.

2

Wide

High

Deep

Mounting

Door Height

Min. Air Space

2

A

B

C

D

D1

E

E1

F

G

G1

H

J

K

30.0 (762)

90.0 (2286)

26.0 (660)

26.5 (673)

1.8 (46)

—

—

17.3 (438)

5.5 (140)

—

84.4 (2143)

4.0 (102)

—

2
2
2

L

M

N

P

R

S

T

U

V

W

RR

SS

TT

UU

VV

Max. Approx.
Shipping Weight
Lbs (kg)

23.5
(597)

3.3
(84)

4.5
(114)

19.3
(490)

—

26.2
(667)

24.8
(629)

—

—

—

93.9
(2386)

—

—

—

—

1500 (681)

Cable Entry

Door Clearance

2
2
V6-T2-108

Volume 6—Solid-State Motor Control CA08100007E—May 2014 www.eaton.com

2.5

Adjustable Frequency Drives
SVX9000 Drives

Approximate Dimensions in Inches (mm)

2

Size 8

2

For Top Cable Entry –
(2 Places)

T

S

2
2

R

2
Top View

2

J

2
2
2
2
2
2

RR

H

B

2
2
2
2
2

U

C

2

V
A
Front View

Side View
0.56 (14.2) Dia.
Mounting Hole –
(4 Places)
IL hp
300
350
400

480V

M

L

2

For Bottom
Cable Entry

2

F

N

2

G

P

2
2

D
Bottom View

D1

2

For reference only, dimensions are subject to change. See Page V6-T2-92, notes 3 and 5 for enclosure and option selection.

2

Wide

High

Deep

Mounting

Door Height

Min. Air Space

A

B

C

D

D1

E

E1

F

G

G1

H

J

K

48.0 (1219)

90.0 (2286)

24.0 (610)

42.2 (1072)

3.0 (77)

—

—

—

5.5 (139)

—

84.4 (2143)

4.0 (102)

—

2
2

L

M

N

P

R

S

T

U

V

W

RR

SS

TT

UU

VV

Max. Approx.
Shipping Weight
Lbs (kg)

9.5
(241)

37.5
(952)

12.5
(318)

7.7
(196)

8.3
(210)

1.3
(32)

31.0
(787)

21.5
(545)

21.3
(541)

—

93.5
(2375)

—

—

—

—

2000 (908)

Cable Entry

2
2
2

Volume 6—Solid-State Motor Control CA08100007E—May 2014 www.eaton.com

V6-T2-109

2.5
2
2

Adjustable Frequency Drives
SVX9000 Drives

Approximate Dimensions in Inches (mm)
Size 9
T

S

U

2

R
Access in Top –
(2 Places)

2

V

W

2
2

SS
TT

2

90° Max.
Door
Opening

90° Max.
Door
Opening

UU

Top View

2

J

2

Openings Filtered for
NEMA Type 12/IP54 Design

2

Drive Circuit Breaker

2
2
2

Key-Locking Handle

RR

2

B

2
Access
Plate –
4 Places

2
2
2

C
Side View

2

A
Front View
M

2

2
2

IH hp

IL hp

400
500
550

500
550
600

480V

2
2

N
G

2
2

Bottom Access

L

0.56 (14.2) Dia.
Mounting Hole –
(5 Places)

P

G1
D1

D

D2
E
Bottom View

For reference only, dimensions are subject to change. See Page V6-T2-92, notes 3 and 5 for enclosure and option selection.
Wide

High

Deep

Mounting

Door Height

Min. Air Space

A

B

C

D

D1

E

E1

F

G

G1

H

J

K

60.0 (1524)

90.0 (2286)

260.1 (664)

22.9 (582)

2.0 (51)

30.0 (762)

44.3 (1125)

10.6 (270)

10.6 (270)

8.2 (208)

—

4.0 (102)

—

2

Cable Entry
L

M

N

P

R

S

T

U

V

W

RR

SS

TT

UU

VV

Max. Approx.
Shipping Weight
Lbs (kg)

2

8.5
(216)

32.7
(831)

12.0
(305)

11.9
(303)

9.8
(249)

1.5
(38)

43.5
(1105)

15.0
(381)

7.5
(191)

25.0
(635)

93.5
(2375)

27.4
(696)

290.1
(738)

270.1
(687)

—

2500 (1135)

2
2
V6-T2-110

Volume 6—Solid-State Motor Control CA08100007E—May 2014 www.eaton.com

2.5

Adjustable Frequency Drives
SVX9000 Drives

Contents

SVX9000 VFD Pump Panels

Description

Page

SVX9000 Drives . . . . . . . . . . . . . . . . . . . . . . . . . . .
SVX9000 Enclosed Drives . . . . . . . . . . . . . . . . . . .
SVX9000 VFD Pump Panels
Catalog Number Selection . . . . . . . . . . . . . . . .
Product Selection . . . . . . . . . . . . . . . . . . . . . . .
Options . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Technical Data and Specifications . . . . . . . . . .
Wiring Diagrams . . . . . . . . . . . . . . . . . . . . . . . .
Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . .

V6-T2-48
V6-T2-87
V6-T2-112
V6-T2-113
V6-T2-118
V6-T2-121
V6-T2-123
V6-T2-124

2
2
2
2
2
2
2
2
2
2
2

SVX9000 VFD Pump Panels
Product Description
●

●

●

Standard Enclosed—
covers a wide range of the
most commonly ordered
options. Pre-engineering
eliminates the lead time
normally associated with
customer specific options.
Modified Standard
Enclosed—applies to
specific customer
requirements that vary
from the Standard
Enclosed offering, such as
the need for an additional
indicating light or minor
modifications to drawings.
Consult your Eaton
representative for
assistance in pricing and
lead time.
Custom Engineered—for
those applications with
more unique or complex
requirements, these are
individually engineered to
the customer’s needs.
Consult your Eaton
representative for
assistance in pricing and
lead time.

●

●

●

●

●
●

2

Product Identification

Features
NEMA Type 12/IP54 or
NEMA Type 3R enclosures
Input voltage: 208V, 230V,
480V and 575V (consult
factory)
Complete range of control,
network and power options
Horsepower range:
●
208V—3/4 to 100 hp IH;
1 to 100 hp IL
●
230V—3/4 to 100 hp IH;
1 to 100 hp IL
●
480V—1 to 350 hp IH;
1-1/2 to 400 hp IL
Padlockable disconnect
Single-phase input
available

SVX9000 Pump Application

2

1

2
2
6

2

2

2
2

3

2
2
2

4

2

Standards and Certifications
●
●

UL Listed
cUL Listed

2

5

2
2
2 Input disconnect Option P1

4 Space heater
Option S9

2

3 Input contactor (included as
standard with bypass option)

5 Bypass contactor
Option RA/RB

2

6 Door-mounted keypad
(included as standard)

2

1 SVX9000 variable frequency drive

2
2
Volume 6—Solid-State Motor Control CA08100007E—May 2014 www.eaton.com

V6-T2-111

2.5

Adjustable Frequency Drives
SVX9000 Drives

2

Catalog Number Selection

2

SVX9000 Enclosed NEMA Type 12/IP54/3R Drive
Build Alphabetically and Numerically

SVX 010 2 4 E P

2
2
2
2
2
2
2

Product Family
SVX = Enclosed drives

F07 = 3/4 hp
001 = 1 hp
F15 = 1-1/2 hp
002 = 2 hp
003 = 3 hp
005 = 5 hp
007 = 7-1/2 hp
010 = 10 hp

2
2
2
2

Application—Torque/Braking 2
A = IL/no brake chopper
B = IL/internal brake chopper
D = IH/no brake chopper
E = IH/internal brake chopper

2
2

Enclosed Style
P = Pumping application

2
2
2
2
2
2

2

K5
K6
K9
L1
L2
LD
LE
LU
LW
P1
P3
P8
PA
PE
PF
PG
RA
S5
S9
SA
SB
SE
SF

Enclosed Options 145
Door-mounted speed potentiometer 3
Door-mounted speed potentiometer with HOA selector
switch 3
MANUAL/AUTO reference switch (22 mm)
START and STOP pushbuttons (22 mm)
(2) Factory installed auxiliary contacts
POWER ON, RUN and Fault pilot lights
Bypass pilot lights for RA bypass option 7
Green STOP light
Red RUN light
Misc. light (22 mm)
PTT light (22 mm)
Input circuit breaker
Input line fuses (200 kAIC)
SPD (50 kA per phase)
SPD (100 kA per phase)
Output contactor
Output filter
MotoRX (300–600 ft) 1000 V/μS DV/DT filter
Manual HOA bypass controller 7
Floor stand 22 in
Space heater w/out CPT
Space heater w/CPT
Socket type control relay
On-delay timer
Off-delay timer

Communication Options 6
C2 = Modbus
C3 = PROFIBUS DP
C4 = LonWorks
C5 = PROFIBUS DP (D9 connector)
C6 = CANopen (slave)
C7 = DeviceNet
C8 = Modbus (D9 type connector)
CA = Johnson Controls N2
CI = Modbus TCP
CJ = BACnet
CQ = EtherNet/IP
D3 = RS-232 with D9 connection

Control Options
B1 = 6 DI, 1 ext +24 Vdc/EXT +24 Vdc
B2 = 1 RO (NC-NO), 1 RO (NO), 1 therm
B4 = 1 AI (mA isolated), 2 AO (mA isolated),
1 ext +24 Vdc/EXT +24 Vdc
B5 = 3 RO (NO)
B8 = 1 ext +24 Vdc/EXT +24 Vdc, 3 Pt100
B9 = 1 RO (NO), 5 DI 42–240 Vac input

2

2

100 = 100 hp
125 = 125 hp
150 = 150 hp
200 = 200 hp
250 = 250 hp
300 = 300 hp
350 = 350 hp
400 = 400 hp

Voltage Rating
Three-phase
Single-phase
1 = 208V
J = 230V
2 = 230V
K = 480V
4 = 480V

2

2

K1
K2

Enclosure Rating
2 = NEMA Type 12/IP54
3 = NEMA Type 3R

2

2

Horsepower Rating
015 = 15 hp
020 = 20 hp
025 = 25 hp
030 = 30 hp
040 = 40 hp
050 = 50 hp
060 = 60 hp
075 = 75 hp

_ _ _ _ _ _ _ _ _ _

Notes
1 Local/remote keypad is included as the standard control panel.
2 Brake chopper is a factory installed option only, see drive options on Page V6-T2-49. External dynamic braking resistors not included. See Page V6-T2-58.
3 Includes local/remote speed reference switch.
4 Some options are voltage and/or horsepower specific. Consult your Eaton representative for details.
5 See Page V6-T2-120 for descriptions.
6 See Pages V6-T2-118 and V6-T2-119 for complete descriptions.
7 Bypass options applicable only in the pump panel three-phase design.

2
2
V6-T2-112

Volume 6—Solid-State Motor Control CA08100007E—May 2014 www.eaton.com

Type
Control
Control
Control
Control
Power
Light
Addl. bypass
Light
Light
Light
Light
Input
Input
Input
Input
Output
Output
Output
Bypass
Enclosure
Enclosure
Enclosure
Enclosure
Enclosure
Enclosure

Adjustable Frequency Drives
SVX9000 Drives

2.5

Product Selection

2

When Ordering
●
Select a base catalog
number that meets the
application requirements—
nominal horsepower,
voltage and enclosure
rating (the enclosed drive’s
continuous output amp
rating should be equal to or

greater than the motor’s
full load amp rating). The
base enclosed package
includes a standard drive,
door mounted local/remote
keypad and enclosure.

●

If dynamic brake chopper
or control/communication
option is desired, change
the appropriate code in the
base catalog number.

●

●

Select enclosed options.
Add the codes as suffixes
to the base catalog number
in alphabetical and numeric
order.
Read all footnotes.

2
2
2
2

208V Drives
SVX9000 Enclosed
Drives

2

Pump Panel Style (Three-Phase)
Enclosure
Size 1

hp

NEMA Type 12/IP54
Frame
Base Catalog
Size
Number 2

2

NEMA Type 3R
Frame
Base Catalog
Size
Number 2

2
2

High Overload Drive and Enclosure
A

3/4

4

SVXF0721EP
SVX00121EP

SVX00131EP

1-1/2

SVXF1521EP

SVXF1531EP

3

SVX00221EP
5

SVX00321EP
SVX00521EP

SVX00531EP

SVX00721EP

SVX00731EP

6

SVX01021EP

20

SVX02021DP

7

SVX02531DP

SVX03021DP

SVX03031DP

SVX04021DP

8

SVX05021DP

60
75

—

100

2
2

SVX04031DP
SVX05031DP

SVX06021DP
9

2

SVX02031DP

SVX02521DP

8

2

SVX01531EP

30
40

2

SVX01031EP

25

50

F

6

SVX01521EP
7

2

SVX00331EP

7-1/2

15

2

SVX00231EP
5

5

10

C

SVXF0731EP

1

2

B

4

2

SVX06031DP
9

—

SVX07531DP
SVX10031DP

2

SVX00131BP

2

Low Overload Drive and Enclosure
A

1

4

SVXF1521BP

SVXF1531BP

2

SVX00221BP

SVX00231BP

5

SVX00321BP
5

SVX00731BP

SVX01021BP

SVX01031BP

25

SVX01521BP

6

SVX02021BP
7

SVX02521AP

7

SVX03031AP

SVX04021AP

SVX04031AP

125

8

SVX06021AP

75
100

SVX05021AP

—
—

2
2

SVX05031AP
SVX06031AP

SVX07521AP
9

2

SVX02531AP

SVX03021AP

8

2

SVX02031BP

40

60

2

SVX01531BP

30

50

2

SVX00531BP

SVX00721BP

6

2

SVX00331BP
5

10

20

F

SVX00521BP

7-1/2

15

C

4

1-1/2

3

B

SVX00121BP

2

SVX07531AP
9

SVX10031AP

2

SVX12531AP

2

Notes
1 Enclosure dimensions starting on Page V6-T2-124.
2 Includes drive, local/remote keypad and enclosure.

Volume 6—Solid-State Motor Control CA08100007E—May 2014 www.eaton.com

2
V6-T2-113

2.5
2
2

Adjustable Frequency Drives
SVX9000 Drives

230V Drives
SVX9000 Enclosed
Drives

Pump Panel Style (Three-Phase)
Enclosure
Size 1

2

hp

NEMA Type 12/IP54
Frame
Base Catalog
Size
Number 2

NEMA Type 3R
Frame
Base Catalog
Size
Number 2

High Overload Drive and Enclosure

2

A

3/4

4

SVXF0722EP

4

SVXF0732EP

1

SVX00122EP

SVX00132EP

1-1/2

SVXF1522EP

SVXF1532EP

2

2

SVX00222EP

2

5

SVX00522EP

7-1/2

SVX00722EP

2

10

2

3

5

6

15

2

B

2
C

2

20

SVX02022DP

25

SVX02522DP

30

SVX03022DP

40

8

SVX04022DP

50

SVX05022DP

60

SVX06022DP

F

2

Low Overload Drive and Enclosure

75

9

100

A

SVX01022EP

1

SVX00232EP
5

—

SVX00732EP
6

SVX01032EP

7

SVX02032DP

SVX01532EP

SVX02532DP
SVX03032DP
8

SVX00122BP

SVX04032DP
SVX05032DP
SVX06032DP

9

—

4

SVX00332EP
SVX00532EP

SVX01522EP
7

2
2

SVX00322EP

SVX07532DP
SVX10032DP

4

SVX00132BP

1-1/2

SVXF1522BP

SVXF1532BP

2

SVX00222BP

SVX00232BP

2

3

SVX00322BP

2

7-1/2

SVX00722BP

10

SVX01022BP

2

15

2

5

5

6

20

2

B

2
C

2
2

F

2

25

SVX00522BP

SVX01522BP

SVX02522AP
SVX03022AP

40

SVX04022AP
8

SVX05022AP

60

SVX06022AP

75

SVX07522AP

100
125

9

—
—

SVX00532BP
SVX00732BP
SVX01032BP

6

SVX01532BP

7

SVX02532AP

SVX02022BP
7

30

50

SVX00332BP
5

SVX02032BP

SVX03032AP
SVX04032AP
8

SVX05032AP
SVX06032AP
SVX07532AP

9

SVX10032AP
SVX12532AP

Notes
1 Enclosure dimensions starting on Page V6-T2-124.
2 Includes drive, local/remote keypad and enclosure.

2
2
2
2
2
2
2
V6-T2-114

Volume 6—Solid-State Motor Control CA08100007E—May 2014 www.eaton.com

Adjustable Frequency Drives
SVX9000 Drives

2.5

230V Drives, continued
SVX9000 Enclosed
Drives

2

Pump Panel Style (Single-Phase)
Enclosure
Size 1

hp

2

NEMA Type 12/IP54

NEMA Type 3R

Frame
Size

Base Catalog
Number 2

Frame
Size

Base Catalog
Number 2

SVXF072JBP

4

SVXF073JBP

5

SVX0023JBP

2

Low Overload Drive and Enclosure
A

3/4

4

1
2

SVX0012JBP
5

SVX0022JBP
SVX0032JBP

SVX0033JBP

5

SVX0052JBP

SVX0053JBP

6

10
B

15

C

25

SVX0072JBP

6

SVX0102JBP
7

20

SVX0152JBP

SVX0252JAP

2
2

SVX0073JBP
SVX0103JBP

7

SVX0153JBP

8

SVX0253JAP

SVX0202JAP
8

2

SVX0013JBP

3

7-1/2

2

2
2

SVX0203JAP

30

SVX0302JAP

SVX0303JAP

40

SVX0402JAP

SVX0403JAP

2
2

Notes
1 Enclosure dimensions starting on Page V6-T2-124.
2 Includes drive, local/remote keypad and enclosure.

2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2

Volume 6—Solid-State Motor Control CA08100007E—May 2014 www.eaton.com

V6-T2-115

2.5
2
2

Adjustable Frequency Drives
SVX9000 Drives

480V Drives
SVX9000 Enclosed
Drives

Pump Panel Style (Three-Phase)
Enclosure
Size 1

2

hp

NEMA Type 12/IP54
Frame
Base Catalog
Size
Number 2

NEMA Type 3R
Frame
Base Catalog
Size
Number 2

High Overload Drive and Enclosure

2

A

1

4

SVX00124EP

4

SVX00134EP

1-1/2

SVXF1524EP

SVXF1534EP

2

2

SVX00224EP

SVX00234EP

3

SVX00324EP

SVX00334EP

2

5

SVX00524EP

2

10

SVX01024EP

15

SVX01524EP

2

20

7-1/2

5

6

25

2

B

2
2

C

2

F

2

30

SVX01034EP
SVX01534EP
6

SVX02034EP

7

SVX03034EP

SVX02534EP

SVX04024DP

SVX04034DP

50

SVX05024DP

SVX05034DP

60

SVX06024DP

75

8

SVX07524DP

100

SVX10024DP

125

SVX12524DP

150

9

—

SVX06034DP
8

—
—

350

—
11 3

500

—

SVX07534DP
SVX10034DP
SVX12534DP

9

—
10

300
400

2

SVX03024EP

SVX00734EP

40

250

2

SVX02024EP

SVX00534EP
5

SVX02524EP
7

200

2

SVX00724EP

SVX15034DP
SVX20034DP

10

SVX25034DP
SVX30034DP
SVX35034DP

11

—

SVX40034DP
SVX50034DP

Low Overload Drive and Enclosure
A

2

1-1/2

4

SVXF1524BP

4

SVXF1534BP

2

SVX00224BP

SVX00234BP

3

SVX00324BP

SVX00334BP

5

SVX00524BP

SVX00534BP

2

7-1/2

SVX00724BP

2

15

SVX01524BP

20

SVX02024BP

2

25

2

10

5

6

30
B

2
2

C

2
2

F

40

SVX01024BP

SVX02524BP
SVX04024BP

SVX01034BP
SVX01534BP
SVX02034BP

6

SVX02534BP

7

SVX04034BP

SVX03024BP
7

SVX03034BP

50

SVX05024AP

SVX05034AP

60

SVX06024AP

SVX06034AP

75

SVX07524AP

100

8

SVX10024AP

125

SVX12524AP

150

SVX15024AP

200

9

—

2

250

2

350

—

400

—

2

500

300

600

2

SVX00734BP
5

SVX07534AP
8

SVX12534AP
SVX15034AP
9

—
10

11 3

—

—
—

SVX10034AP

SVX20034AP
SVX25034AP

10

SVX30034AP
SVX35034AP
SVX40034AP

11

SVX50034AP
SVX60034AP

Notes
1 Enclosure dimensions starting on Page V6-T2-124.
2 Includes drive, local/remote keypad and enclosure.
3 FR11 has limited power options available.

2
V6-T2-116

Volume 6—Solid-State Motor Control CA08100007E—May 2014 www.eaton.com

Adjustable Frequency Drives
SVX9000 Drives

2.5

480V Drives, continued
SVX9000 Enclosed
Drives

2

Pump Panel Style (Single-Phase)
Enclosure
Size 1

hp

NEMA Type 12/IP54
Frame
Base Catalog
Size
Number 2

2

NEMA Type 3R
Frame
Base Catalog
Size
Number 2

2

Low Overload Drive and Enclosure
A

3/4

4

2

SVX0022KBP

SVX0023KBP

3

SVX0032KBP

SVX0033KBP

5

SVX0052KBP

5

SVX0072KBP

SVX0073KBP

10

SVX0102KBP

SVX0103KBP

6

25

6

SVX0202KBP
7

30
40

SVX0152KBP

SVX0252KAP

SVX0402KAP

2
2
2

SVX0153KBP
SVX0203KBP

7

SVX0302KAP
8

2

SVX0053KBP

7-1/2

20

2

SVXF073KBP
SVX0013KBP

15

C

4

SVX0012KBP

5

B

SVXF072KBP

1

2

SVX0253KAP
SVX0303KAP

8

2

SVX0403KAP

50

SVX0502KAP

SVX0503KAP

60

SVX0602KAP

SVX0603KAP

2
2

Notes
1 Enclosure dimensions starting on Page V6-T2-124.
2 Includes drive, local/remote keypad and enclosure.

2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2

Volume 6—Solid-State Motor Control CA08100007E—May 2014 www.eaton.com

V6-T2-117

2.5
2
2
2

Adjustable Frequency Drives
SVX9000 Drives

Options
9000X Series Option Board Kits
The 9000X Series drives can accommodate a wide selection of expander and adapter option boards
to customize the drive for your application needs. The drive’s control unit is designed to accept a
total of five option boards.

2

The 9000X Series factory installed standard board configuration includes an A9 I/O board and an A2
relay output board, which are installed in slots A and B.

2

Option Boards

Option Board Kits
Field
Installed

Factory
Installed

SVX Ready Programs

Allowed Slot
Locations 2

Catalog
Number

Option
Designator

Basic

Local/
Remote

Standard

MSS

PID

Multi-P. PFC

6 DI, 1 DO, 2 AI, 1AO, 1 +10 Vdc ref,
2 ext +24 Vdc/EXT +24 Vdc

A

OPTA9

—

■

■

■

■

■

■

■

2 RO (NC-NO)

B

OPTA2

—

■

■

■

■

■

■

■

2
Option Kit Description 1

2
2

Standard I/O Cards
A

D E
B C

2

Extended I/O Cards

2

6 DI, 1 ext +24 Vdc/EXT +24 Vdc

B, C, D, E

OPTB1

B1

—

—

—

—

—

■

■

1 RO (NC-NO), 1 RO (NO), 1 therm

B, C, D, E

OPTB2

B2

—

—

—

—

—

■

■

1 AI (mA isolated), 2 AO (mA isolated),
1 ext +24 Vdc/EXT +24 Vdc

B, C, D, E

OPTB4

B4

■

■

■

■

■

■

■

3 RO (NO)

B, C, D, E

OPTB5

B5

—

—

—

—

—

■

■

2

1 ext +24 Vdc/EXT +24 Vdc, 3 Pt100

B, C, D, E

OPTB8

B8

—

—

—

—

—

—

—

1 RO (NO), 5 DI 42–240 Vac input

B, C, D, E

OPTB9

B9

—

—

—

—

—

■

■

2

Communication Cards

2
2

Modbus 3

D, E

OPTC2

C2

■

■

■

■

■

■

■

2

Modbus TCP

D, E

OPTCI

CI

■

■

■

■

■

■

■

2

BACnet

D, E

OPTCJ

CJ

■

■

■

■

■

■

■

EtherNet/IP

D, E

OPTCQ

CQ

■

■

■

■

■

■

■

2

Johnson Controls N2 3

D, E

OPTC2

CA

—

—

—

—

—

—

—

PROFIBUS DP

D, E

OPTC3

C3

■

■

■

■

■

■

■

2

LonWorks

D, E

OPTC4

C4

■

■

■

■

■

■

■

PROFIBUS DP (D9 connector)

D, E

OPTC5

C5

■

■

■

■

■

■

■

2

CANopen (slave)

D, E

OPTC6

C6

■

■

■

■

■

■

■

2

DeviceNet

D, E

OPTC7

C7

■

■

■

■

■

■

■

Modbus (D9 type connector)

D, E

OPTC8

C8

■

■

■

■

■

■

■

RS-232 with D9 connection

D, E

OPTD3

D3

■

■

■

■

■

■

■

2

Notes
1 AI = Analog Input; AO = Analog Output, DI = Digital Input, DO = Digital Output, RO = Relay Output
2 Option card must be installed in one of the slots listed for that card. Slot indicated in bold is the preferred location.
3 OPTC2 is a multi-protocol option card.

2
2
2
2
2
2
2
2
2
V6-T2-118

Volume 6—Solid-State Motor Control CA08100007E—May 2014 www.eaton.com

Adjustable Frequency Drives
SVX9000 Drives

Modbus RTU Network
Communications
The Modbus Network Card
OPTC2 is used for connecting
the 9000X Drive as a slave on
a Modbus network. The
interface is connected by a
9-pin DSUB connector
(female) and the baud rate
ranges from 300 to 19200
baud. Other communication
parameters include an
address range from 1 to 247;
a parity of None, Odd or
Even; and the stop bit is 1.

DeviceNet Network
Communications
The DeviceNet Network Card
OPTC7 is used for connecting
the 9000X Drive on a
DeviceNet Network. It
includes a 5.08 mm pluggable
connector. Transfer method
is via CAN using a two-wire
twisted shielded cable with
two-wire bus power cable
and drain. The baud rates
used for communication
include 125K baud, 250K
baud and 500K baud.

PROFIBUS Network
Communications
The PROFIBUS Network Card
OPTC3 is used for connecting
the 9000X Drive as a slave
on a PROFIBUS-DP network.
The interface is connected
by a 9-pin DSUB connector
(female). The baud rates
range from 9.6K baud to 12M
baud, and the addresses
range from 1 to 127.

Johnson Controls
Metasys N2 Network
Communications
The OPTC2 fieldbus board
provides communication
between the 9000X Drive and
a Johnson Controls
Metasys™ N2 network. With
this connection, the drive can
be controlled, monitored and
programmed from the
Metasys system. The N2
fieldbus is available as a
factory installed option and as
a field installable kit.

LonWorks Network
Communications
The LonWorks Network Card
OPTC4 is used for connecting
the 9000X Drive on a
LonWorks network. This
interface uses Standard
Network Variable Types
(SNVT) as data types. The
channel connection is
achieved using a FTT-10A
Free Topology transceiver
via a single twisted transfer
cable. The communication
speed with LonWorks is
78 kBits/s.
CANopen (Slave)
Communications
The CANopen (Slave)
Network Card OPTC6 is used
for connecting the 9000X
Drive to a host system.
According to ISO11898
standard cables to be chosen
for CAN bus should have a
nominal impedance of 120
ohms, and specific line delay
of nominal 5 nS/m. 120 ohms
line termination resistors
required for installation.

Modbus/TCP Network
Communications
The Modbus/TCP Network
Card OPTCI is used for
connecting the 9000X Drive
to Ethernet networks utilizing
Modbus protocol. It includes
an RJ-45 pluggable connector.
This interface provides a
selection of standard and
custom register values to
communicate drive parameters.
The board supports 10 Mbps
and 100 Mbps communication
speeds. The IP address of the
board is configurable over
Ethernet using a supplied
software tool.

2.5

BACnet Network
Communications
The BACnet Network Card
OPTCJ is used for connecting
the 9000X Drive to BACnet
networks. It includes a
5.08 mm pluggable connector.
Data transfer is Master-Slave/
Token Passing (MS/TP)
RS-485. This interface uses
a collection of 30 Binary Value
Objects (BVOs) and 35 Analog
Value Objects (AVOs) to
communicate drive parameters.
The card supports 9.6, 19.2
and 38.4 Kbaud communication
speeds and supports network
addresses 1–127.

2
2
2
2
2
2
2
2
2

EtherNet/IP Network
Communications
The EtherNet/IP Network
Card OPTCK is used for
connecting the 9000X Drive
to Ethernet/Industrial Protocol
networks. It includes an
RJ-45 pluggable connector.
The interface uses CIP
objects to communicate drive
parameters (CIP is “Common
Industrial Protocol”, the same
protocol used by DeviceNet).
The board supports 10 Mbps
and 100 Mbps communication
speeds. The IP address of the
board is configurable by Static,
BOOTP and DHCP methods.

2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2

Volume 6—Solid-State Motor Control CA08100007E—May 2014 www.eaton.com

V6-T2-119

2.5
2
2
2

Adjustable Frequency Drives
SVX9000 Drives

Control/Communication Option Descriptions
For availability, see Product Selection for base drive voltage required.
Available Control/Communications Options
Option

Description

Option Type

K1

Door-Mounted Speed Potentiometer—Provides the SVX9000 with the ability to adjust the frequency reference using a door-mounted potentiometer. This option uses
the 10 Vdc reference to generate a 0–10V signal at the analog voltage input signal terminal. When the HOA bypass option is added, the speed is controlled when the
HOA switch is in the HAND position. Without the HOA bypass option, a two-position switch (labeled local/remote) is provided on the keypad to select speed reference from the
Speed Potentiometer or a remote speed signal.

Control

K2

Door-Mounted Speed Potentiometer with HOA Selector Switch—Provides the SVX9000 with the ability to start/stop and adjust the speed reference from
door-mounted control devices or remotely from customer supplied inputs. In HAND position, the drive will start and the speed is controlled by the door-mounted speed
potentiometer. The drive will be disabled in the OFF position. When AUTO is selected, the drive run and speed control commands are via user-supplied dry contact and
4–20 mA signal.

Control

K5

MANUAL/AUTO Speed Reference Switch—Provides a door-mounted selector switch for MANUAL/AUTO speed reference.

Control

K6

START and STOP Pushbuttons (22 mm)—START (green) STOP (red). Provide door-mounted START and STOP pushbuttons for either bypass or
non-bypass configurations.

Control

K9

(2) Factory Installed Auxiliary Contacts—Provide two NO/NC auxiliary contacts.

Power

L2

Bypass Pilot Lights for RA and RB Bypass Options—A green MOTOR ON INVERTER light indicates when the motor is running in inverter mode and an amber
MOTOR ON BYPASS light indicates when the motor is running in bypass mode. The lights are mounted on the enclosure door, above the switches.

Addl. bypass

LD

Green STOP Light (22 mm)—Provides a green STOP light that indicates the drive is stopped.

Light

2

LE

Red RUN Pilot Light (22 mm)—Provides a red RUN pilot light that indicates the drive is running.

Light

LU

Misc. Light (22 mm)—Provides a misc. “user defined” pilot light. User to define light function and color.

Light

2

LW

PTT (Push-To-Test) Light (22 mm)—Provides misc. “user defined” PTT pilot light. User to define light function and color.

Light

P1

Input Circuit Breaker—Provides a means of short-circuit protection for the power cables between it and the SVX9000, and protection from high-level ground faults on
the power cable. Allows a convenient means of disconnecting the SVX9000 from the line and the operating mechanism can be padlocked in the OFF position. This is factory
mounted in the enclosure.

Input

2

P3

Input Line Fuses Rated to 200 kAIC—Provide high-level fault protection of the SVX9000 input power circuit from the load side of the fuses to the input side of the
power transistors. This option consists of three 200 kA fuses, which are factory mounted in the enclosure.

Input

2

P8

SPD (50 kA per Phase)—Provides a surge protection device (SPD) connected to the line side terminals and is designed to clip line side transients.
Rated for 50,000A.

Input

2

PA

SPD (100 kA per Phase)—Provides a surge protection device (SPD) connected to the line side terminals and is designed to clip line side transients.
Rated for 100,000A.

Input

PE

Output Contactor—Provides a means for positive disconnection of the drive output from the motor terminals. The contactor coil is controlled by the drive’s run or
permissive logic. NC and NO auxiliary contacts rated at 10A, 600 Vac are provided for customer use. Bypass option RA includes an output contactor as standard. This
option includes a low VA 115 Vac fused control power transformer and is factory mounted in the enclosure.

Output

RA

Manual HOA Bypass Controller—The Manual HAND/OFF/AUTO (HOA)—3-contactor—bypass option provides a means of bypassing the SVX9000, allowing the AC
motor to be operated at full speed directly from the AC supply line. This option consists of an input disconnect, a fused control power transformer, and a full voltage
bypass starter with a door mounted HOA selector switch and an INVERTER/BYPASS switch. The HOA switch provides the ability to start and stop the drive in the inverter
mode. For applications up to 100 hp, a Freedom Series IEC input contactor, a Freedom Series IEC output contactor, and a Freedom Series IEC starter with a bimetallic
overload relay is included. For applications above 100 hp, an Advantage input contactor, an Advantage output contactor and an Advantage starter with electronic
overload protection is included. The contactors are mechanically and electrically interlocked.

Bypass

RB

Manual IOB Bypass Controller—The manual INVERTER/OFF/BYPASS (IOB)—3-contactor—bypass option provides a means of bypassing the SVX9000, allowing
the AC motor to be operated at full speed directly from the AC supply line. This option consists of an input disconnect, a fused control power transformer, and a full
voltage bypass starter with a door mounted IOB selector switch. For applications up to 100 hp, a Freedom Series IEC input contactor, a Freedom Series IEC output
contactor, and a Freedom Series IEC starter with a bimetallic overload relay is included. For applications above 100 hp, an Advantage input contactor, an Advantage
output contactor and an Advantage starter with electronic overload protection is included. The contactors are mechanically and electrically interlocked.

Bypass

2
2
2
2
2
2
2

2

2
2
2
2
2
2

S5

Floor Stand 22 in—Converts a Size A or B, normally wall mounted enclosure to a floor standing enclosure with a height of 22 in (558.8 mm).

Enclosure

S9

Enclosure

2

Space Heater without CPT—Prevents condensation from forming in the enclosure when the drive is inactive or in storage. Includes a thermostat for variable
temperature control. A 200W heater is installed in enclosures A and B, and 400W heater is installed in enclosures C and D. Requires a customer supplied 115V remote
supply source.

SA

2

Space Heater with CPT— Prevents condensation from forming in the enclosure when the drive is inactive or in storage. Includes a thermostat for variable temperature Enclosure
control. A 200W heater is installed in enclosures A and B, and 400W heater is installed in enclosures C and D. Provided with CPT connected to load side of input disconnect.

SB

Ice Cube Style Control Relay—Provides misc. “user defined” 4PDT control relay. Requires user to define functionality.

Enclosure

SE

On-Delay Timer (Delay on Make)—Provides misc. “user defined” time delay relay. Requires user to define functionality and time setting requirement.

Enclosure

SF

Off-Delay Timer (Delay on Break)—Provides misc. “user defined” time delay relay. Requires user to define functionality and time setting requirement.

Enclosure

2

2
2
2
2
2

V6-T2-120

Volume 6—Solid-State Motor Control CA08100007E—May 2014 www.eaton.com

Adjustable Frequency Drives
SVX9000 Drives

2.5

Technical Data and Specifications

2

9000X VFD Pump Panels
Description

NEMA Type 12/IP54 or NEMA Type 3R
Specification

Primary Design Features

Description

NEMA Type 12/IP54 or NEMA Type 3R
Specification

Input/Output Interface Features

45–66 Hz input frequency

Standard

Output (AC volts maximum)

Input voltage base

Remote keypad/display

Standard

Output frequency range

0–320 Hz

Personal computer

Standard

Initial output current (IH)

250% for 2 seconds

Overload (1 minute [IH/IL])

150%/110%

Drive mounted keypad/display

Enclosure space heater

Optional

Remote keypad/display

Standard

Oversize enclosure

Standard

Conventional control elements

Standard

Output contactor

Optional

Serial communications

Optional

Bypass motor starter

Optional

115 Vac control circuit

Optional

Listings

UL, cUL

2

Standard

2
2
2

Speed setting inputs
Standard

Optional

0–10 Vdc potentiometer/voltage signal

Standard

AC input circuit disconnect

Optional

4–20 mA isolated

Configurable

Line reactors (3%)

Standard

4–20 mA differential

Configurable

Phase rotation insensitive

Standard

EMI filter

Standard—Thru Frame 9

Speed/frequency

Input phase loss protection

Standard

Torque/load/current

Programmable

Input overvoltage protection

Standard

Motor voltage

Programmable

Line surge protection

Optional

Kilowatts

Programmable

Output short-circuit protection

Standard

0–10 Vdc signals

Configurable w/jumpers

Output ground fault protection

Standard

4–20 mA DC signals

Standard
Optional

Incoming line fuses

2

Operator control provisions

Keypad

2
2

Setup adjustment provisions

Protection Features

2

2
2
2

Analog outputs
Standard

2
2
2
2

Output phase protection

Standard

Isolated signals

Overtemperature protection

Standard

Discrete outputs

DC overvoltage protection

Standard

Fault alarm

Drive overload protection

Standard

Drive running

Standard

Motor overload protection

Standard

Drive at set speed

Programmable

Programmer software

Optional

Optional parameters

14

Local/remote keypad

Standard

Dry contacts

1 (2 relays Form C)

Keypad lockout

Standard

Open collector outputs

1

Fault alarm output

Standard

Additional discrete outputs

Optional

Built-in diagnostics

Standard

2

RS-232

Standard

RS-422/485

Optional

2

2

Standard

2
2
2

Communications

DeviceNet™

Optional

Modbus RTU

Optional

CANopen (slave)

Optional

PROFIBUS-DP

Optional

Lonworks®

Optional

Johnson Controls Metasys™ N2

Optional

EtherNet/IP

Optional

Modbus TCP

Optional

BACnet

Optional

2
2
2
2
2
2
2
2

Volume 6—Solid-State Motor Control CA08100007E—May 2014 www.eaton.com

V6-T2-121

2.5

Adjustable Frequency Drives
SVX9000 Drives

2

9000X VFD Pump Panels, continued

2

Description

Standard I/O Specifications

NEMA Type 12/IP54 or NEMA Type 3R
Specification

Description

Specification

Six–digital input
programmable

24V: “0” <10V, “1” >18V,Ri >5 kohms

Two–analog input
configurable w/jumpers

Voltage: 0–±10V, Ri >200 kohms
Current: 0 (4)–20 mA, Ri = 250 ohms

Two–digital output
programmable

Form C relays 250 Vac
30 Vdc 2 amp resistive

One–analog output
programmable
configurable w/jumper

0–20 mA, RL max. 500 ohms 10 bits ±2%

One digital output
programmable

Open collector 48 Vdc 50 mA

Performance Features

2

Sensorless vector control

Standard

2

Volts/hertz control

Standard

IR and slip compensation

Standard

2

Electronic reversing

Standard

Dynamic braking

Optional 1

2

DC braking

Standard

PID setpoint controller

Programmable

2

Critical speed lockout

Standard

2

Current (torque) limit

Standard

Adjustable acceleration/deceleration

Standard

I/O Specifications for Control/Communication Options
Specification
0–±10V, Ri >200 kohms

2

Linear or S curve accel/decel

Standard

Description

Jog at preset speed

Standard

Analog voltage, input

2

Thread/preset speeds

7 Standard, 15 Optional

Analog current, input

0 (4)–20 mA, Ri = 250 ohms

Automatic restart

Selectable

Digital input

24V: “0” <10V, “1” >18V, Ri >5 kohms

Coasting motor start

Standard

Auxiliary voltage

24V (±20%), max. 50 mA

Standard

Reference voltage

10V ±3%, max. 10 mA

Analog current, output

0 (4)–20 mA, RL = 500 kohms, resolution
10 bit, accuracy <±2%

Analog voltage, output

0 (2)–10V, RL >1 k kohms, resolution 10 bit,
accuracy <±2%

2
2

Coast or ramp stop selection
Elapsed time meter

Optional

2

Carrier frequency adjustment

1–16 kHz

2

Operating ambient temperature

0 to 40°C

2

Storage temperature

–40 to 60°C

Maximum switching voltage

Humidity (maximum), non-condensing

95%

Maximum switching load

8A/24 Vdc, 0.4A/300 Vdc, 2 kVA/250 Vac

2

Altitude (maximum without derate)

3300 ft (1000m)

Maximum continuous load

2A rms

Line voltage variation

+10/–15%

2

Line frequency variation

45–66 Hz

Efficiency

>96%

Power factor (displacement)

0.96

2

Standard Conditions for Application and Service

Relay output

Thermistor input

Rtrip = 4.7 kohms

Note
1 Some horsepower units include dynamic braking chopper as standard—refer to individual
drive sections.

2
2
2
2
2
2
2
2
2
2
2
2
V6-T2-122

300 Vdc, 250 Vac

Volume 6—Solid-State Motor Control CA08100007E—May 2014 www.eaton.com

2.5

Adjustable Frequency Drives
SVX9000 Drives

Wiring Diagrams
A9 Board Control Wiring
Basic I/O
Board A9

2

SVX9000 Pump Panel Bypass Power Wiring

2

Incoming Power
L2
L1
L3

+10Vref
AI1+

1

GND
AI2+

3
4

AI2-

5

Input Reference
(Current)

24Vout

6

Control Voltage Output

GND
DIN1

7
8

DIN2

9

Input Reference
(Voltage)

2

2

Bypass
Circuit
Breaker

2
2
2

Optional Fuse

2

24V

DIN3 10
CMA 11

GND

24Vout 12

L1

L2

2

L3

GND 13

2

To Drive Input

DIN4 14
DIN5 15
DIN6 16

24V

2

To Drive Output

GND

CMB 17
AO1+ 18

RL<500 W
+ V<+48V
I<50 mA

2

U(T1) V(T2)W(T3)

0 (4)/20 mA

AO1- 19
DO1 20

Output
Contactor

Bypass
Contactor

2
2

Indicates Connections for Inverted Signals

A2 Board Control Wiring
Basic Relay
Board A2

RO1/1

2

Overload
Relay

2

21
V(T2)

RO1/2

22

RO1/3

23

RO2/1

24

RO2/2

25

RO2/3

26

U(T1)

RL

2

W(T3)
Motor

AC / DC
Max. Current/Voltage
Switching:
<8A / 24 Vdc
<0.4A / 300 Vdc
<2 kVA / 250 Vac
Continuously <2 Arms

2
SVX9000 Pump Panel Disconnect Power Wiring

2

Incoming Power
L2
L1
L3

2
2

Circuit
Breaker

2
2

Optional Fuse

2
2

To Drive Input

To Drive Output

2

U(T1) V(T2)W(T3)

2

Optional
Output
Contactor

2
2
2

V(T2)
U(T1)

W(T3)
Motor

Volume 6—Solid-State Motor Control CA08100007E—May 2014 www.eaton.com

2
V6-T2-123

2.5
2

Adjustable Frequency Drives
SVX9000 Drives

Dimensions
Approximate Dimensions in Inches (mm)

2

SVX9000 Pump Application Drives

2

Enclosure Box A NEMA Type 12/IP54

2

4.00 (101.6)
Minimum Free Air
Space Required

2

3.00 (76.2)
Minimum Air
Space
Required
Both Sides

2
2
2
2

H1 H2

H

2
2
2
2

0.44 (11.2)
Mounting
Holes
(4 Places)

W1
W

D1

D

2
2
2
2
2
2
2
2

Voltage
AC

hp
(IH)

hp
(IL)

Approx.
Shipping Weight
Lbs (kg)

H

H1

H2

W

W1

D

D1

29.00
(736.6)

27.00
(685.8)

25.35
(643.9)

16.92
(429.8)

15.30
(388.6)

16.26
(413.0)

2.34
(59.4)

120 (54)

160 (73)

29.00
(736.6)

27.00
(685.8)

25.35
(643.9)

16.92
(429.8)

15.30
(388.6)

16.26
(413.0)

2.34
(59.4)

120 (54)

160 (73)

Three-Phase

2

208V

3/4–10

1–15

230V

3/4–10

1–15

2

480V

1–25

1–30

2

230V

—

3/4–10

480V

—

3/4–20

2

Approx.
Weight
Lbs (kg)

Single-Phase

2
2
2
2
2
V6-T2-124

Volume 6—Solid-State Motor Control CA08100007E—May 2014 www.eaton.com

Adjustable Frequency Drives
SVX9000 Drives

2.5

Approximate Dimensions in Inches (mm)

2

Enclosure Box B NEMA Type 12/IP54

2

4.00 (101.6)
Minimum Free Air
Space Required

2

3.00 (76.2)
Minimum Air
Space
Required
Both Sides

2
2
2
2
2

H

H1 H2

2
2
2
2
2

0.44 (11.2)
Mounting
Holes
(4 Places)

W1
W

2
D1

D

2
2
2
2
2
2

hp
(IH)

hp
(IL)

208V

15–25

20–30

230V

15–25

20–30

480V

30–60

40–75

Voltage
AC

H

H1

H2

W

W1

D

D1

40.00
(1016.0)

38.00
(965.2)

36.35
(923.3)

20.92
(531.4)

19.30
(490.2)

16.76
(425.7)

2.34
(59.4)

Approx.
Weight
Lbs (kg)

Approx.
Shipping Weight
Lbs (kg)

2

185 (84)

229 (104)

2

Three-Phase

2

Single-Phase
230V

—

15–20

480V

—

25–30

2

40.00
(1016.0)

38.00
(965.2)

36.35
(923.3)

20.92
(531.4)

19.30
(490.2)

16.76
(425.7)

2.34
(59.4)

185 (84)

2

229 (104)

2
2
2
2
2

Volume 6—Solid-State Motor Control CA08100007E—May 2014 www.eaton.com

V6-T2-125

2.5
2
2
2

Adjustable Frequency Drives
SVX9000 Drives

Approximate Dimensions in Inches (mm)
Enclosure Box C NEMA Type 12/IP54
0.44 (11.2)
Mounting 4.00 (101.6) Minimum
Holes
Free Air Space Required
(4 Places)

0.44 (11.2)
Mounting
Holes
(4 Places)

3.00 (76.2)
Minimum Air Space
Required Both Sides

W1

3.00 (76.2)
Minimum Air Space
Required Both Sides

4.00 (101.6) Minimum
Free Air Space Required

2
2
2
2
2

H

H1 H2

2

H2

H3

H4

2
2
2

W1
W

D1

D

2
2
2

D

D1

W

2
2
2
2
2
2

Voltage
AC

hp
(IH)

hp
(IL)

208V

30–50

40–60

230V

30–50

40–60

480V

75–125

100–150

2

Single-Phase

2

H

H1

H2

H3

H4

W

W1

D

D1

52.00
(1320.8)

50.00
(1270.0)

48.35
(1228.1)

72.00
(1828.8)

71.19
(1808.2)

30.92
(785.4)

29.30
(744.2)

16.78
(426.2)

2.34
(59.4)

1

52.00
(1320.8)

50.00
(1270.0)

48.35
(1228.1)

72.00
(1828.8)

71.19
(1808.2)

30.92
(785.4)

29.30
(744.2)

16.78
(426.2)

2.34
(59.4)

1

Three-Phase

2
2

Approx.
Shipping Weight
Lbs (kg)

230V

—

25–40

480V

—

40–60

Note
1 Consult factory.

2
2
2
2
2
V6-T2-126

Volume 6—Solid-State Motor Control CA08100007E—May 2014 www.eaton.com

Adjustable Frequency Drives
SVX9000 Drives

2.5

Approximate Dimensions in Inches (mm)

2

Enclosure Box A NEMA Type 3R
W

2

D

2
2
2
2
2

H

2

H1 H2 H3

2
2
2
2

W2
W1

W3

D2

D1

2

0.44 (11.2)
Mounting
Holes
(4 Places)

2
2
2
2
2
2
2

Voltage
AC

hp
(IH)

hp
(IL)

H

H1

H2

H3

W

W1

W2

W3

D

D1

D2

33.00
(838.2)

31.36
(796.5)

29.67
(753.6)

25.35
(643.9)

21.05
(534.7)

16.92
(429.8)

15.30
(388.6)

2.07
(52.6)

17.24
(437.9)

16.26
(413.0)

3.31
(84.1)

Approx.
Weight
Lbs (kg)

Approx.
Shipping Weight
Lbs (kg)

170 (77)

215 (98)

Three-Phase
208V

3/4–10

1–15

230V

3/4–10

1–15

480V

1–25

1–30

—

3/4–10

480V

—

3/4–20

2
2
2
2

Single-Phase
230V

2

33.00
(838.2)

31.36
(796.5)

29.67
(753.6)

25.35
(643.9)

21.05
(534.7)

16.92
(429.8)

15.30
(388.6)

2.07
(52.6)

17.24
(437.9)

16.26
(413.0)

3.31
(84.1)

170 (77)

215 (98)

2
2
2
2
2

Volume 6—Solid-State Motor Control CA08100007E—May 2014 www.eaton.com

V6-T2-127

2.5
2
2

Adjustable Frequency Drives
SVX9000 Drives

Approximate Dimensions in Inches (mm)
Enclosure Box B NEMA Type 3R
W

D

2
2
2
2
2
2
2

H2
H

H1

2

H3

2
2
2
2
2
2

W2
W1

W3

D1

D2

2

0.44 (11.2)
Mounting
Holes
(4 Places)

2
2
2
2
2
2
2
2
2

Voltage
AC

hp
(IH)

hp
(IL)

H2

H3

W

W1

W2

W3

D

D1

D2

Approx.
Weight
Lbs (kg)

46.09
44.45
(1170.7) (1129.0)

42.77
(1086.4)

36.35
(923.3)

26.31
(668.3)

20.92
(531.4)

19.30
(490.2)

2.69
(68.3)

17.74
(450.6)

16.76
(425.7)

3.31
(84.1)

235
(107)

290
(132)

46.09
44.45
(1170.7) (1129.0)

42.77
(1086.4)

36.35
(923.3)

26.31
(668.3)

20.92
(531.4)

19.30
(490.2)

2.69
(68.3)

17.74
(450.6)

16.76
(425.7)

3.31
(84.1)

235
(107)

290
(132)

H

H1

Approx.
Shipping Weight
Lbs (kg)

Three-Phase
208V

15–25

20–30

2

230V

15–25

20–30

480V

30–60

40–75

2

Single-Phase
230V

—

15–20

2

480V

—

25–30

2
V6-T2-128

Volume 6—Solid-State Motor Control CA08100007E—May 2014 www.eaton.com

2.5

Adjustable Frequency Drives
SVX9000 Drives

Approximate Dimensions in Inches (mm)

2

Enclosure Box C NEMA Type 3R
0.44 (11.2)
Mounting Holes
(4 Places)
W

W
W2

D

2

0.44 (11.2)
Mounting Holes
(4 Places)
D

2
2
2
2
2

H1 H2
H3

2

H2
H3

H

2
H4

H5

2
2
2

W2
W1
W3

D2

2

D1

2
2
2

D1

W1
D2

2
2
2

Voltage
AC

hp
(IH)

hp
(IL)

H

H1

Approx.
Weight
Lbs (kg)

H2

H3

H4

H5

W

W1

W2

W3

D

D1

D2

58.09
56.45
(1475.5) (1433.8)

54.77
(1391.2)

48.35
(1228.1)

78.09
(1983.5)

77.64
(1972.1)

37.73
(958.3)

30.92
(785.4)

29.30
(744.2)

3.34
(84.8)

17.74
(450.6)

16.77
(426.0)

3.31
(84.1)

1

58.09
56.45
(1475.5) (1433.8)

54.77
(1391.2)

48.35
(1228.1)

78.09
(1983.5)

77.64
(1972.1)

37.73
(958.3)

30.92
(785.4)

29.30
(744.2)

3.34
(84.8)

17.74
(450.6)

16.77
(426.0)

3.31
(84.1)

1

Three-Phase
208

30–50

40–60

230

30–50

40–60

480

75–125

100–150

—

25–40

480V

—

40–60

2
2
2
2

Single-Phase
230V

2

2
2

Note
1 Consult factory.

2
2
2
2
Volume 6—Solid-State Motor Control CA08100007E—May 2014 www.eaton.com

V6-T2-129

2.5
2
2

Adjustable Frequency Drives
SVX9000 Drives

Approximate Dimensions in Inches (mm)
Enclosure Size F
W

D

2
2
2
2
2
2
2
H1

2

H

2
2
2
2
2

W1

D1

2
2
2
2
2
2
2

H

H1

W

W1

D

D1

2

93.58
(2376.9)

69.51
(1765.60)

60.00
(1524.0)

48.00
(1219.2)

37.50
(952.5)

26.00
(660.4)

Approximate
Weight
Lbs (kg)

Approximate
Shipping Weight
Lbs (kg)

1700 (771)

1850 (839)

2
2
2
2
2
2
2
V6-T2-130

Volume 6—Solid-State Motor Control CA08100007E—May 2014 www.eaton.com

Adjustable Frequency Drives
H-Max Series Drives

2.6

Contents

H-Max Series Drives

Description
H-Max Series Drives
H-Max Drives . . . . . . . . . . . . . . . . . . . . . . . . . .
H-Max IntelliPass and
IntelliDisconnect Drives . . . . . . . . . . . . . . . . .

Page

2

V6-T2-132

2

V6-T2-141

2
2
2
2
2
2
2
2
2

Product Overview
H-Max Family Introduction
Eaton’s H-Max™ Series VFD
is the next generation of
drives specifically engineered
for HVAC pump and fluid
control applications. The
H-Max family of products
boasts industry leading
energy efficiency algorithms
for your applications. Not only
are the drives ultra-efficient—
they contain software that
minimizes motor winding
energy loses in your
applications. Designed for
easy installation, simple
startup, and long life; the
H-Max Series drive family
provides exceptional value
to our customers,

Product Range
Open Style Drives:
0.75–125 hp at 230 Vac
●
1.5–250 hp at 480 Vac
●

Note: Available in NEMA 1 or
NEMA 12 designs.

IntelliPass/IntelliDisconnect
Drives:
●
1–30 hp at 208 Vac
●
1–30 hp at 230 Vac
●
1–75 hp at 480 Vac
Note: Available in NEMA 1,
NEMA 12, or NEMA 3R
enclosures.

Application Description

Key Feature

The H-Max Series drive was
designed specifically for
HVAC pump and fluid control
applications. It is intended to
be used on variable torque
loads with the intent of moving
air or liquids. With this in mind,
the H-Max drive has onboard
I/O pre-programmed to meet
the common needs for these
applications. The H-Max drive
supports items such as
standard speed control,
PID functionality, as well as
multi-motor applications. The
drive easily supports
interlock, second motor
parameter set, as well as fire
mode functionality.

Active Energy Control Algorithm
Eaton’s H-Max Series drives
have been designed to provide
industry leading energy saving
solutions. Not only is the
drive ultra-efficient, the drive
seeks the most efficient
operating point of the motor,
minimizing energy loss in the
windings per the given load
requirements. This is an
Eaton protected control
algorithm exclusive to
H-Max drives.

2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2

Volume 6—Solid-State Motor Control CA08100007E—May 2014 www.eaton.com

V6-T2-131

2.6
2

Adjustable Frequency Drives
H-Max Series Drives

Contents

H-Max Drives

Description

2

Page

H-Max Drives
Catalog Number Selection . . . . . . . . . . . . . . . .
Product Selection . . . . . . . . . . . . . . . . . . . . . . .
Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . .
Replacement Parts . . . . . . . . . . . . . . . . . . . . . .
Technical Data and Specifications . . . . . . . . . .
Wiring Diagram . . . . . . . . . . . . . . . . . . . . . . . .
Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . .
H-Max IntelliPass and IntelliDisconnect Drives . . .

2
2
2
2

V6-T2-133
V6-T2-134
V6-T2-137
V6-T2-137
V6-T2-138
V6-T2-139
V6-T2-140
V6-T2-141

2
2
2
2
2

H-Max Drives

2

Product Description

Features and Benefits

Eaton’s H-Max Series VFD
has software and hardware
designed specifically for the
HVAC, pump industry. The
ultra-efficient DC capacitor
and power structure allows
the drive to consume less
energy, lowering greenhouse
gases.

Hardware
●
Thin metal capacitor
design—ultra-efficient
drive operation and
extended self life (up to
five years without
reforming)
●
Integrated 5% DC link
choke with Input surge
protection—protects
against voltage spikes and
provides a clean wave form
to the motor
●
EMI/RFI filters standard on
all drives—meets EMC
Category 2 for commercial
applications
●
Real-time clock—supports
calendaring and PLC
functionality
●
Graphic LCD display and
keypad—supports simple
menu navigation as well as
on-screen diagnostics and
troubleshooting
●
HAND-OFF-AUTO and
drive-bypass selector on
keypad—simplifies control
●
Standard I/O: 6DI, 2AI,
1AO, 2 Form C RO (NO/
NC), 1 Form A RO (NO)—
supports requirements for
most installations

2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2

The I/O configuration is
designed with wiring
ergonomics in mind by
including removable terminal
blocks. The main, easily
removable, control board
used for all drive frames with
six digital IN, two analog IN,
one analog OUT, three relay
OUT accepts two additional
I/O or communication board.
In addition, the control board
has built-in RS-485 and
Ethernet communication.
These drives continue
the tradition of robust
performance, and raise
the bar on features and
functionality, ensuring
the best solution at the
right price.
In addition to the Active
Energy Control Algorithm to
maximize motor efficiency,
the drive boasts an ultraefficient DC capacitor and
power structure to allow less
energy consumption,
lowering greenhouse gases.

V6-T2-132

Standards and Certifications
●

●

●

●

Onboard RS 485: Modbus,
N2, BACnet—meets needs
of most communication
requirements
Onboard Ethernet: BACnet/
IP, Modbus/TCP—meets
needs of most
communication
requirements
Two expansion slots—
intended to support
additional I/O or
communication protocols
as necessary
Quick disconnect terminals
for I/O connections—
supports fast easy
installation

Software
●
Active energy control—
minimizes energy losses in
your motor resulting in
industry leading energy
efficiency for your
application
●
Quick Start Wizard upon
initial power up—supports
fast easy installation
●
Copy/paste functionality on
drive keypad—allows for
fast setup of multiple
drives
●
Pre-programmed I/O—
supports fast easy
installation for most
applications

Volume 6—Solid-State Motor Control CA08100007E—May 2014 www.eaton.com

Product
●
IEC 61800-5-1
●
CE
●
UL508C
●
cUL
●
C-Tick Mark
●
OSHPD Seismic Certified
●
Plenum Rated

Adjustable Frequency Drives
H-Max Series Drives

2.6

Catalog Number Selection

2

H-Max Series Drives

2

HMX 3 4 A G 3D4 2 1 - N
Product
HMX = HVAC drive

2
Braking/Application
N = No brake chopper (low overload)

2
2

Phase
3 = Three-phase

Enclosure
1 = Open NEMA Type 1 IP21
2 = Open NEMA Type 12 IP54

Voltage
2 = 200–240V
4 = 380–480V

2
2

Input Options Frame and
Voltage Specific
2 = EMC C2

2
2

Software Series
A–Z

2

Keypad
G = Graphical panel

200–240 Volts
3D7 = 3.7A–0.75 hp, 0.55 kW
4D8 = 4.8A–1 hp, 0.75 kW
6D6 = 6.6A–1.5 hp, 1.1 kW
8D0 = 8A–2 hp, 1.5 kW
011 = 11A–3 hp, 2.2 kW
012 = 12A–4 hp, 3 kW
018 = 18A–5 hp, 4 kW
024 = 24A–7.5 hp, 5.5 kW
031 = 31A–10 hp, 7.5 kW
048 = 48A–15 hp, 11 kW

2
062 =
075 =
088 =
105 =
140 =
170 =
205 =
261 =
310 =

Amperes
380–480 Volts
62A–20 hp, 15 kW
3D4 = 3.4A–1.5 hp, 1.1 kW
75A–25 hp, 18.5 kW
4D8 = 4.8–2 hp, 1.5 kW
88A–30 hp, 22 kW
5D6 = 5.6A–3 hp, 2.2 kW
105A–40 hp, 30 kW
8D0 = 8A–4 hp, 3 kW
140A–50 hp, 37 kW
9D6 = 9.6A–5 hp, 4 kW
170A–60 hp, 45 kW
012 = 12A–7.5 hp, 5.5 kW
205A–75 hp, 55 kW
016 = 16A–10 hp, 7.5 kW
261A–100 hp, 75 kW
023 = 23A–15 hp, 11 kW
310A–125 hp, 90 kW
031 = 31A–20 hp, 15 kW
038 = 38A–25 hp, 18.5 kW

2
046 =
061 =
072 =
087 =
105 =
140 =
170 =
205 =
261 =
310 =

2

46A–30 hp, 22 kW
61A–40 hp, 30 kW
72A–50 hp, 37 kW
87A–60 hp, 45 kW
105A–75 hp, 55 kW
140A–100 hp, 75 kW
170A–125 hp, 90 kW
205A–150 hp, 110 kW
261A–200 hp, 132 kW
310A–250 hp, 160 kW

2
2
2
2

Notes
All boards are varnished (conformed coated). Corrosion resistant.
Battery included in all drives for real-time clock.
Keypad kit includes HOA bypass.
Keypad kit includes HOA, back reset for Europe application.
EMI/RFI filters included.
DC link choke included.

2
2
2
2
2
2
2
2
2
2
2
2
2
Volume 6—Solid-State Motor Control CA08100007E—May 2014 www.eaton.com

V6-T2-133

2.6
2
2
2

Adjustable Frequency Drives
H-Max Series Drives

Product Selection
H-Max Series Drives—230 Vac
NEMA Type 1

2
2

NEMA Type 1/IP21
FS
Frame
Size

Drive Output Current
Low Overload Full
Load Amps at 40°C

4

3.7
4.8
6.6

2
2
2

5

2

6

2

7

2
2

8

2
2

9

2
2

NEMA Type 12

Assigned Motor Ratings
Drive kW
230 Vac
230 Vac/50 Hz
NEC Amps 1

Low Overload Full
Load Amps at 50°C

Catalog
Number

0.75

0.55

3.2

2.6

HMX32AG3D721-N

1

0.75

4.2

3.7

HMX32AG4D821-N

1.5

1.1

6.6

4.8

HMX32AG6D621-N

8

2

1.5

6.8

6.6

HMX32AG8D021-N

11

3

2.2

9.6

8

HMX32AG01121-N

12.5

4

3

N/A

11

HMX32AG01221-N

18

5

4

15.2

12.5

HMX32AG01821-N

24

7.5

5.5

22

18

HMX32AG02421-N

31

10

7.5

28

24

HMX32AG03121-N

48

15

11

42

31

HMX32AG04821-N

62

20

15

54

48

HMX32AG06221-N

75

25

18.5

68

62

HMX32AG07521-N

88

30

22

80

75

HMX32AG08821-N

105

40

30

104

88

HMX32AG10521-N

140

50

37

130

105

HMX32AG14021-N

170

60

45

154

140

HMX32AG17021-N

205

75

55

192

170

HMX32AG20521-N

261

100

75

248

205

HMX32AG26121-N

310

125

90

N/A

261

HMX32AG31021-N

Horsepower

Assigned Motor Ratings
230 Vac
Drive kW
NEC Amps 1
230 Vac/50 Hz

Low Overload Full
Load Amps at 50°C

Catalog
Number

Horsepower

NEMA Type 12/IP54

2

FS
Frame
Size

Drive Output Current
Low Overload Full
Load Amps at 40°C

2

4

3.7

0.75

0.55

3.2

2.6

HMX32AG3D722-N

4.8

1

0.75

4.2

3.7

HMX32AG4D822-N

6.6

1.5

1.1

6.6

4.8

HMX32AG6D622-N

2

8

2

1.5

6.8

6.6

HMX32AG8D022-N

11

3

2.2

9.6

8

HMX32AG01122-N

2

12.5

4

3

N/A

11

HMX32AG01222-N

18

5

4

15.2

12

HMX32AG01822-N

24

7.5

5.5

22

18

HMX32AG02422-N

31

10

7.5

28

24

HMX32AG03122-N

48

15

11

42

31

HMX32AG04822-N

62

20

15

54

48

HMX32AG06222-N

75

25

18.5

68

62

HMX32AG07522-N

88

30

22

80

75

HMX32AG08822-N

105

40

30

104

88

HMX32AG10522-N

140

50

37

130

105

HMX32AG14022-N

170

60

45

154

140

HMX32AG17022-N

205

75

55

192

170

HMX32AG20522-N

261

100

75

248

205

HMX32AG26122-N

310

125

90

N/A

261

HMX32AG31022-N

2

5

2
2

6

2

7

2
8

2
2

9

2

Note
1 For sizing reference.

2
2
V6-T2-134

Volume 6—Solid-State Motor Control CA08100007E—May 2014 www.eaton.com

2.6

Adjustable Frequency Drives
H-Max Series Drives

H-Max Series Drives—480 Vac
NEMA Type 1

FS
Frame
Size

Drive Output Current
Low Overload Full
Load Amps at 40°C

4

5

6

7

8

9

NEMA Type 12

2

NEMA Type 1/IP21

2

Horsepower

Assigned Motor Ratings
Drive kW
480 Vac
400 Vac/50 Hz
NEC Amps 1

Low Overload Full
Load Amps at 50°C

Catalog
Number

2

3.4

1.5

1.1

2.1

2.6

HMX34AG3D421-N

4.8

2

1.5

3.4

3.4

HMX34AG4D821-N

2

5.6

3

2.2

5.6

4.8

HMX34AG5D621-N

8.0

4

3.0

N/A

5.6

HMX34AG8D021-N

9.6

5

4

7.6

8

HMX34AG9D621-N

12

7.5

5.5

11

9.6

HMX34AG01221-N

16

10

7.5

14

12

HMX34AG01621-N

23

15

11

21

16

HMX34AG02321-N

31

20

15

27

23

HMX34AG03121-N

38

25

18.5

34

31

HMX34AG03821-N

46

30

22

40

38

HMX34AG04621-N

61

40

30

52

46

HMX34AG06121-N

72

50

37

65

61

HMX34AG07221-N

87

60

45

77

72

HMX34AG08721-N

105

75

55

96

87

HMX34AG10521-N

140

100

75

124

105

HMX34AG14021-N

170

125

90

156

140

HMX34AG17021-N

205

150

110

180

170

HMX34AG20521-N

261

200

132

240

205

HMX34AG26121-N

310

250

160

302

261

HMX34AG31021-N

Drive Output Current
Low Overload Full
Load Amps at 40°C

4

3.4

5

6

7

8

9

2
2
2
2
2
2
2
2
2
2

NEMA Type 12/IP54
FS
Frame
Size

2

2

Horsepower

Assigned Motor Ratings
Drive kW
480 Vac
400 Vac/50 Hz
NEC Amps 1

Low Overload Full
Load Amps at 50°C

Catalog
Number

1.5

1.1

2.1

2.6

HMX34AG3D422-N

4.8

2

1.5

3.4

3.4

HMX34AG4D822-N

5.6

3

2.2

5.6

4.8

HMX34AG5D622-N

8.0

4

3.0

N/A

5.6

HMX34AG8D022-N

9.6

5

4

7.6

8

HMX34AG9D622-N

12

7.5

5.5

11

9.6

HMX34AG01222-N

16

10

7.5

14

12

HMX34AG01622-N

23

15

11

21

16

HMX34AG02322-N

31

20

15

27

23

HMX34AG03122-N

38

25

18.5

34

31

HMX34AG03822-N

46

30

22

40

38

HMX34AG04622-N

61

40

30

52

46

HMX34AG06122-N

72

50

37

65

61

HMX34AG07222-N

87

60

45

77

72

HMX34AG08722-N

105

75

55

96

87

HMX34AG10522-N

140

100

75

124

105

HMX34AG14022-N

170

125

90

156

140

HMX34AG17022-N

205

150

110

180

170

HMX34AG20522-N

261

200

132

240

205

HMX34AG26122-N

310

250

160

302

261

HMX34AG31022-N

Note
1 For sizing reference.

2
2
2
2
2
2
2
2
2
2
2
2
2
2

Volume 6—Solid-State Motor Control CA08100007E—May 2014 www.eaton.com

V6-T2-135

2.6
2
2
2
2
2
2
2

Adjustable Frequency Drives
H-Max Series Drives

Onboard Network Communications
Johnson Controls
Metasys N2
H-Max Series provides
communication between the
drive and a Johnson Controls
Metasys™ N2 network. With
this connection, the drive can
be controlled, monitored and
programmed from the
Metasys system. N2 can be
selected and programmed by
the drive keypad.

BACnet

Modbus RTU

H-Max Series provides
communication to BACnet
networks. Data transfer is
master-slave/token passing
(MS/TP) RS-485.

H-Max Series provides
communication to Modbus
RTU RS-485 as a slave on a
Modbus network. Other
communication parameters
include an address range
from 1–247; a parity of
None, Odd or Even; and the
stop bit is 1.

BACnet IP
100Base-T interface.
Modbus TCP
Ethernet based protocol.

2
2
2

H-Max Series Option Board Kits Available for Slot B
The factory issued relay
option board can be replaced
with the following option

boards to customize the drive
for your application needs.

The standard board provides
2 Form C RO (NO/NC) and
1 Form A RO (NO).

2

Option Boards Mounted in Slot B

2

Option Kit Description

Option Kit
Catalog Number

I/O expander card, 2 RO and thermistor input

Relay Board 2

2
2
2
2
2

H-Max Series Option Board Kits Available for Slots D and E
The H-Max Series drives can
accommodate a wide
selection of expander and
adapter option boards to
customize the drive for your

application needs. The drive’s
control unit is designed to
accept a total of two option
boards.

The H-Max Series factoryinstalled standard board
configuration includes an
I/O board and a relay
output board.

Option Boards Mounted in Slots D and E

2

Option Kit Description

Option Kit
Catalog Number

6 x DI /DO, each digital input can be individually programmed as digital output

XMX-IO-B1-A

2

1RO Form C (NO/NC), 1RO Form A (NO), 1 thermistor

XMX-IO-B2-A

1 x AI, 2 x AO (isolated)

XMX-IO-B4-A

2

3 x RO Form A (NO)

XMX-IO-B5-A

2

1RO Form A (NO), 5DI 42–240 Vac input

XMX-IO-B9-A

1 x AO, 1 x DO, 1 x RO

XMX-IO-BF-A

LonWorks®

XMX-COM-C4-A

2

2
2
2
2

NEMA Type 1 to NEMA Type 12/IP54 Conversion Kit
The NEMA Type 12/IP54
option kit is used to convert a
NEMA Type 1 to a NEMA
Type 12 drive.

Kit consists of a drive cover,
fan kit and plugs.

2

NEMA Type 12/IP54 Cover

2

Option Kit Description

Option Kit
Catalog Number

2

FS4-branded N12/IP54 cover with gasket, plastic plug, fans, Eaton logos

FS4-N12KIT

FS5-branded N12/IP54 cover with gasket, plastic plug, fans, Eaton logos

FS5-N12KIT

FS6-branded N12/IP54 cover with gasket, plastic plug, fans, Eaton logos

FS6-N12KIT

2
V6-T2-136

Volume 6—Solid-State Motor Control CA08100007E—May 2014 www.eaton.com

2.6

Adjustable Frequency Drives
H-Max Series Drives

Accessories

Replacement Parts

Flange Kits
The flange kit is used when the power section heat sink is
mounted through the back panel of an enclosure.

Control Board/Keypad
Description

Current Catalog
Number

Flange Kit NEMA Type 12/IP54
Includes flange, mounting brackets, NEMA Type 12 fan
components, air shroud screws and plugs.

H-Max Series graphic bypass, HOA

KeypadbypassHOA

H-Max Series graphic back, HOA

KeypadbackHOA

2

Description

Catalog
Number

NEMA Type 12/IP54
FS4 N12/IP54 flange kit
(mounting N1 drive into N12 enclosure)

FS4-Flange-N12KIT

FS5 N12/IP54 flange kit
(mounting N1 drive into N12 enclosure)

FS5-Flange-N12KIT

FS6 N12/IP54 flange kit
(mounting N1 drive into N12 enclosure)

FS6-Flange-N12KIT

FS7 N12/IP54 flange kit
(mounting N1 drive into N12 enclosure)

FS7-Flange-N12KIT

Description
Remote download USB to RJ-45 cable with
software driver disk

Catalog
Number
REM-USB-Down

Replacement relay board
qty 2 Form C relay, qty 1 Form A relay

Catalog
Number

Description
FS4 main fan

FS4-Main Fan

Remote Mounting Keypad Kit

FS5 main fan

FS5-Main Fan

FS6 main fan

FS6-Main Fan

FS7 main fan

FS7-Main Fan

Frames FS4–FS9
Description

Catalog
Number

Remote mounting keypad kit—bezel and cable

OPTRMT-BP-HMAX

2

2
2

Main Fan

Keypad Accessories

2

2

Relay board 1

Catalog
Number

2

2

Replacement Relay Board in Slot B
Description

2
2

PC Cable
Frames FS4–FS7 12

2

2
2
2
2

Internal Fan
Description

Catalog
Number

2

FS4 internal fan (IP54/NEMA 12)

FS4-Internal Fan

FS5 internal fan (IP54/NEMA 12)

FS5-Internal Fan

2

H-Max Series Drive Demo

FS6 internal fan (IP54/NEMA 12)

FS6-Internal Fan

Demos and Power Supply

FS7 internal fan (IP54/NEMA 12)

FS7-Internal Fan

Drive Demo

Description

Catalog
Number

H-Max Series bypass demo

H-MAX-BYPASS-DEMO

Hand-held 24V auxiliary power supply—used to supply power
to the control module in order to perform keypad programming
before the drive is connected to line voltage

9000XAUX24V

2
2
2
2
2

Notes
1 For installation of a NEMA Type 1 drive into a NEMA Type 12 oversized enclosure.
2 Frame size 8 and 9 must be ordered from the factory as a flange mount unit.

2
2
2
2
2
2
2
2

Volume 6—Solid-State Motor Control CA08100007E—May 2014 www.eaton.com

V6-T2-137

2.6

Adjustable Frequency Drives
H-Max Series Drives

2

Technical Data and Specifications

2

H-Max Series Drives

2
2
2
2
2

Description

Specification

Input Ratings

Description

Specification

Control Connections

Input voltage (Vin)

200–240 Vac, 380–480 Vac, –10%/+10%

Input frequency (fin)

50/60 Hz (variation up to 47–66 Hz)

Connection to power

Once per minute or less (typical operation)

Short-circuit withstand
rating

100 kAIC

Output Ratings
Output voltage

0 to Vin/Uin line voltage in

Analog input voltage

0 to 10V, R = 200 kohms differential
Resolution 0.1%; Accuracy ±1%
DIP switch selection (voltage/current)

Analog input current

0(4) to 20 mA; Ri –250 ohms differential

Digital inputs (6)

Positive or negative logic; 18 to 30 Vdc

Auxiliary voltage

+24V ±10%, max. 250 mA

Output reference voltage

+10V +3%, max. load 10 mA

Analog output

0–10V, 0(4) to 20 mA; RL max. 500 ohms;
Resolution 10 bit; Accuracy ±2%
DIP switch selection (voltage/current)

Relay outputs

3 programmable, 2 Form C, 1 Form A relay outputs
Switching capacity: 24 Vdc/8A, 250 Vac/8A, 125 Vdc/0.4A

Hard wire jumper

Between terminal 6 and 10 factory default

DIP switch setting default

RS-485 = off
A01 = current
A12 = current
A11 = voltage

Continuous output current

Ambient temperature max. 104°F (40°C)

2

IL overload

1.1 x IL (1 min./10 min.)

2

Overload current

110% (1 min./10 min.)

Initial output current

150% for two seconds

2

Output frequency

0 to 320 Hz

2

Control Characteristics

2

Control method

Frequency control (V/f) open loop sensorless vector control

Switching frequency

1–310 amps
FS4–9: default 6 kHz

2

Frequency reference

Analog input: Resolution 0.1% (10-bit), accuracy ±1%
Panel reference: Resolution 0.01 Hz

Overvoltage protection

Yes

2

DC bus regulation anti-trip

Yes (accelerates or decelerates the load)

Field weakening point

8 to 320 Hz

Undervoltage protection

Yes

Acceleration time

0.1 to 3000 seconds

Earth fault protection

Deceleration time

0.1 to 3000 seconds

Yes (in case of earth fault in motor or motor cable,
only the frequency converter is protected)

Braking torque

DC brake: 30% x Tn

2

Frequency resolution

0.01 Hz

2

Ambient Conditions

2

Ambient operating
temperature

2
2
2

FS4–FS9: 14°F (–10°C), no frost to 104°F (40°C)
(Drive can operate at 122°F (50°C), see Pages V6-T2-134 and
V6-T2-135)

Storage temperature

–40° to 158°F (–40° to 70°C)

Relative humidity

0 to 95% RH, noncondensing, non-corrosive, no dripping water

Air quality

Chemical vapors: IEC 60721-3-3, unit in operation, Class 3C2;
Mechanical particles: IEC 60721-3-3, unit in operation, Class 3S2

Altitude

100% load capacity (no derating) up to 3280 ft (1000m);
1% derating for each 328 ft (100m) above 3280 ft (1000m);
max. 9842 ft (3000m); 380–480V

Vibration

FS4–FS9: EN 61800-5-1, EN 60068-2-6; 5 to 150 Hz,
displacement amplitude 1 mm (peak) at 5 to 15.8 Hz,
max. acceleration amplitude 1G at 15.8 to 150 Hz

2

Shock

EN 61800-5-1, EN 60068-2-27 UPS Drop test (for applicable UPS
weights) Storage and shipping: max. 15G, 11 ms (in package)

2

Enclosure class

NEMA Type 1/IP21 or NEMA Type 12/IP54
(keypad required for IP54/Type 12)

2

Standards

2
2

2

EMC

Immunity: Fulfills all EMC immunity requirements;
Emissions: EN 61800-3, LEVEL H (EMC C2)

Emissions

EMC level dependent—
+EMC 2: EN61800-3 (2004) Category C2
Delivered with Class C2 EMC filtering as default.

2

Protections
Overcurrent protection

Input phase supervision

Yes (trips if any of the input phases are missing)

Motor phase supervision

Yes (trips if any of the output phases are missing)

Overtemperature protection Yes
Motor overload protection

Yes

Motor stall protection

Yes

Motor underload protection Yes
Short-circuit protection

Yes

Surge protection

Yes (varistor input)

Conformed coated
(varnished) boards

Yes (prevents corrosion)

2
2
2
V6-T2-138

Yes

Volume 6—Solid-State Motor Control CA08100007E—May 2014 www.eaton.com

2.6

Adjustable Frequency Drives
H-Max Series Drives

Wiring Diagram

2

Control Input/Output, PID Application
RJ-45

2

BACnet/IP Ethernet Industrial Protocol
Modbus/TCP Transmission Control Protocol (Ethernet Based)

Optional

L1
L2
L3

Three-Phase Input
Input
(Single-Phase not available)

Slot A
Terminal
Resistor

Factory
Jumper

1

+10V

2

AI–1+

3

Vin

4

AI–2+

5

AI–2–

2

U (T1)
V (T2)

2

Motor

2

W (T3)

2

Factory Default Signal

6

24Vout

Reference Output
Analog Input Voltage (Range 0–10 Vdc)
(can be programmed to current 4–20 mA)
Analog Output Common (Ground)
Analog Input Current (Range 4–20 mA)
(can be programmed to voltage 0–10 Vdc)
PI Setpoint or Feedback
Analog Input Common
PI Setpoint or Feedback
Control Voltage Output (0.1A max.)

7

GND

I/O Ground

8

DIN1

START/STOP (Contact closed = start)

9

DIN2

External Fault (Closed = fault)
Run Interlock Permissive IP Interlock
(Closed = OK)
DIN1–DIN6 Common

2

12 24Vout

Control Voltage Output (0.1A max.)

13 GND

I/O Ground

2

14 DIN4

Speed Select 0–100% (Preset speed)

15 DIN5

Fire Mode (Contact closed = fire mode)

16 DIN6

Force Bypass (Contact closed = bypass)

17 CMB

DIN1–DIN6 Common

18 AO–1+

Output Frequency (0–20 mA)

10 DIN3
11

COM

19 AO–1–

Analog Output Common (Ground)

30 24 Vdcin

Auxiliary Input Voltage

A
B
21
22

DATADATA+

RS-485 DATARS-485 DATA+
Relay Board 1
Default Signal
RO1 Bypass Run

Programmable BACnet,
Modbus, FLN, N2
Slot B

23
24
25

RO2 Drive Run

24 Vdc/8A
250 Vac/8A
125 Vdc/0.4A

2
2
2

Test
OFF
VOLTAGE
VOLTAGE
VOLTAGE

ON
CURRENT
CURRENT
CURRENT

2

RS485
AO1
AI2
AI1

2
2
2
2

Terminal Block Layout

2

21

22

23

24

25

26

32

33

RO1

RO1

RO1

RO2

RO2

RO2

RO3

RO3

NC

COM

NO

NC

COM

NO

COM

NO

13

14

15

16

17

18

30

A

DI4

DI5

DI6

COM
DI1–6

AO1+

12

24 Vdc GND
out

19

2

B

AO1– 24 Vdc RS-485 RS-485
in
Data– Data+

1

2

3

4

5

6

7

8

9

10

11

+10
Vdc

AI1+

AI1–

AI2+

AI2–

24 Vdc
out

GND

DI1

DI2

DI3

COM
DI1–6

Slot E __________________

Analog

Three-Phase
Output

Optional
Resistor

Slot D __________________

Circuit
Breaker

5% DC Link
Reactor

DB R+
Chopper R-

26

33

Standards
●
Digital inputs D1–D6, relay
out, analog in/out are freely
programmed
●
The user can assign a
single input to multiple
functions

Factory Jumper
External Interlock

Includes
●
Six digital input
●
Two analog input
●
One analog output
●
Three relay output
●
RS-485
●
Ethernet (BACnet and
Modbus)

2
2
2
2
2

Reliability
●
Pretested components
●
Conformal coated
(varnished) boards
●
40°C rated
●
110% overload for one
minute
●
Eaton Electrical Services &
Systems national network
of AF drive specialists

Volume 6—Solid-State Motor Control CA08100007E—May 2014 www.eaton.com

2

2

32
RO3 Fault

2

2
2
2
2
V6-T2-139

2.6
2
2

Adjustable Frequency Drives
H-Max Series Drives

Dimensions
Approximate Dimensions in Inches (mm)
H-Max Series Frames FS4–FS7

2

W2

2
2
2

H1

H3

H2

W1

2
2

W3

D

2
2

Voltage

hp

kW

Amps

D

H1

Hole
Center-to-Center
H2

7.77
(197.3)

12.89
(327.5)

12.32
(313.0)

11.22
(285.0)

5.04
(128.0)

3.94
(100.0)

3.94
(100.0)

13.2
(6)

8.73
(221.6)

16.50
(419.0)

15.98
(406.0)

15.04
(382.0)

5.67
(144.0)

4.53
(115.0)

3.94
(100.0)

22.0
(10)

9.29
(236.0)

21.93
(557.0)

21.28
(540.5)

20.24
(514.0)

7.68
(195.0)

5.83
(148.0)

5.83
(148.0)

44.1
(20)

10.49
(266.5)

25.98
(660.0)

25.39
(645.0)

24.29
(617.0)

9.06
(230.0)

7.48
(190.0)

7.48
(190.0)

82.6
(37.5)

230 Vac

0.75–4

0.55–3.0

3.7–12.5

2

480 Vac

1.5–7.5

1.1–5.5

3.4–12

FS5

2

230 Vac

5–10

4–7.5

18–31

480 Vac

10–20

7.5–15

16–31

2

FS6
230 Vac

15–20

11–15

48–62

2

480 Vac

25–40

18.5–30

38–61

2

230 Vac

25–30

18.5–30

75–105

480 Vac

50–75

37–55

72–105

2

W3

Weight in
Lbs (kg)

H-Max Series Frames FS8 and FS9
W2

W1

2
2

W2

FS7

2
2

W1

FS4

2

2

H3

W3

H3

H2

H1

2
2

D

2
2
2
2
2
2

hp

kW

Amps

D

H1

Hole
Center-to-Center
H2

230 Vac

50–75

37–55

140–205

480 Vac

100–150

75–110

13.76
(349.6)

38.02
(965.7)

37.26
(946.4)

37.26
(946.4)

11.42
(290.1)

9.29
(236.0)

1.42
(36.0)

154.3
(70)

230 Vac

100–120

75–90

261–310

480 Vac

200–250

132–160

14.63
(371.6)

33.09
(890.4)

31.89
(810.0)

31.89
(810.0)

18.90
(480.0)

15.75
(400.0)

1.57
(40.0)

238.1
(108)

Voltage

H3

W1

W2

W3

Weight in
Lbs (kg)

FS8

FS9

Note: For flange dimension, please reference User Manual.

V6-T2-140

Volume 6—Solid-State Motor Control CA08100007E—May 2014 www.eaton.com

Adjustable Frequency Drives
H-Max Series Drives

2.6

Contents

H-Max IntelliPass and IntelliDisconnect Drives

Description

Page

H-Max Drives . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
H-Max IntelliPass and IntelliDisconnect Drives
Catalog Number Selection . . . . . . . . . . . . . . . .
Product Selection . . . . . . . . . . . . . . . . . . . . . . .
Technical Data and Specifications . . . . . . . . . .
Wiring Diagrams . . . . . . . . . . . . . . . . . . . . . . . .
Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . .

V6-T2-132
V6-T2-142
V6-T2-143
V6-T2-151
V6-T2-152
V6-T2-154

2
2
2
2
2
2
2
2
2
2
2

H-Max IntelliPass and IntelliDisconnect Drives
Product Description

Features and Benefits

The IntelliPass electronic
bypass is a two or optional
three contactor design using a
24 Vdc XT Series contactor
with an optional manual
override switch that allows
the unit to run in bypass
without the H-Max Series
drive.

Industry-leading energy
saving solution—uses the
Eaton H-Max drive with
Active Energy Control
algorithm.

The IntelliPass software
parameters utilize engineering
units common to the HVAC
industry. Onboard startup
wizard guarantees flawless
commissioning with plugand-play screen entry.
Available in NEMA/UL Type 1,
Type 12 and Type 3R with
optional pre-engineered
operator devices to meet
all customized specification
requirements.

Built to be as tough as the
application—Eaton’s robust
design boasts an industrial
grade enclosure and industry
proven components.
●
●
●

Industrial Power Supply
XT Contactors
22 mm Pilot Devices

Standards and Certifications
Designed with Our Customers
in Mind
●
Removable top and bottom
entry panels
●
Door-mounted graphic
display and keypad
●
Easily accessible
connection terminals with
removable I/O terminal
connections

Product
●
IEC 61800-5-1
●
UL508C
●
cUL
●
OSHPD Seismic Certified

2
2
2
2
2
2

Engineered Product Solution
●
The Eaton H-Max
IntelliPass and
IntelliDisconnect products
are available with a variety
of factory tested and
certified options meeting
or exceeding UL508C
requirements

2
2
2
2
2
2

The IntelliPass construction
features allow for easy
installation, reliable operation
and serviceability with
additional onboard wire space,
and removable conduit plates
with knockouts.

2
2
2
2
2
2
2
Volume 6—Solid-State Motor Control CA08100007E—May 2014 www.eaton.com

V6-T2-141

2.6

Adjustable Frequency Drives
H-Max Series Drives

2

Catalog Number Selection

2

H-Max Series IntelliPass and IntelliDisconnect Drives

HMX 011 3 4 N A

2
2
2
2
2
2
2
2
2
2
2
2

Product
HMX = HVAC drive (VT)
(low overload)
NEC Ampere Ratings
208 Volts
480 Volts
4D6 = 4.6A—1 hp
2D1 = 2.1A—1 hp
7D5 = 7.5A—2 hp
3D4 = 3.4A—2 hp
011 = 11A—3 hp
5D6 = 5.6A—3 hp
017 = 17A—5 hp
7D6 = 7.6A—5 hp
025 = 25A—7.5 hp
011 = 11A—7.5 hp
031 = 31A—10 hp
014 = 14A—10 hp
047 = 47A—15 hp
021 = 21A—15 hp
060 = 60A—20 hp
027 = 27A—20 hp
075 = 75A—25 hp
034 = 34A—25 hp
088 = 88A—30 hp
040 = 40A—30 hp
052 = 52A—40 hp
230 Volts
065 = 65A—50 hp
4D2 = 4.2A—1 hp
077 = 77A—60 hp
6D8 = 6.8A—2 hp
096 = 96A—75 hp
9D6 = 9.6A—3 hp
016 = 16A—5 hp
022 = 22A—7.5 hp
028 = 28A—10 hp
042 = 42A—15 hp
054 = 54A—20 hp
068 = 68A—25 hp
080 = 80A—30 hp

_ _ Build
_ options
_ alphabetically
_ _ and_numerically.
_ _ _
Software Series
A–Z

Braking/Application
N = No brake chopper
(low overload)
Voltage

Optional Communications in Slot D and E
C4 = LonWorks

1 = 208V
2 = 230V
4 = 480V

3
4
5
A
B
C

=
=
=
=
=
=

EMC Upgrade Option
EMC C2 Standard

Enclosure Style
IntelliPass NEMA Type 1
IntelliPass NEMA Type 12
IntelliPass NEMA Type 3R
IntelliDisconnect NEMA Type 1
IntelliDisconnect NEMA Type 12
IntelliDisconnect NEMA Type 3R

L3
P3
PE
SA

2
2

2
2
2
2
2

IntelliDisconnect Options
Pilot lights (Power ON, RUN, Fault)
Fused drive isolation
Output contactor
Space heater w/transformer (Type 3R only)

Standard Onboard Communications
RS-485 Communications
BACnet MS/TP = Master slave/token protocol (Universal BACnet) RS-485
Modbus RTU RS-485, ASCII or RTU, remote terminal unit 32 nodes
N2 = Johnson Controls Metasys N2 network
Onboard Ethernet-Based Communications
(port left side of keypad)
BACnet/IP Ethernet industrial protocol
Modbus/TCP Transmission control protocol (Ethernet-based)

2

2

=
=
=
=

Keypad Options
None available

IntelliPass Bypass Options
L4 = Pilot lights (Power ON, RUN, Fault, Bypass)
P3 = Fused drive isolation (can not be used with P6 or MI)
P6 = Third contactor drive isolation
(cannot be used with P3, IS or MI)
M1 = Manual bypass, includes isolation contactor and pilot
lights (not available with P3, L4, P6 or IS)
SA = Space heater w/transformer (Type 3R only)
K9 = Auxiliary contacts
IS = Isolation switch (cannot be used with P6 or MI)

2

2

Extended I/O Options in Slot D and E
B1 = 6 x DI /DO, Each digital input can be individually
programmed as digital output
B2 = 1RO (NC/NO), 1RO (NO), 1 Thermistor
B4 = 1 x AI, 2 x AO (isolated)
B5 = 3 x RO
B9 = 1RO (NO), 5 DI 42–240 Vac input
BF = Expander IO, 1 AO, 1 DO, 1 RO

Notes
IntelliPass—two contactor electronic bypass standard.
All boards are varnished. Corrosion resistant.
Battery included in all drives for real-time clock. Three year lifetime.
Keypad kit includes HOA bypass.
EMI/RFI filters included.
DC link choke included.

2
2
2
2
2
V6-T2-142

Volume 6—Solid-State Motor Control CA08100007E—May 2014 www.eaton.com

Adjustable Frequency Drives
H-Max Series Drives

2.6

Product Selection

2

H-Max Series IntelliPass NEMA Type 1—Two Contactor Bypass Standard
HMX_

2

208 Vac
FS
Frame Size
4

5

Horsepower

Drive Rated
NEC Amps

2

Catalog Number

1

4.6

HMX4D631NA

2

7.5

HMX7D531NA

3

10.6

HMX01131NA

5

16.7

HMX01731NA

7.5

24.2

HMX02531NA

10

30.8

HMX03131NA

6

15

46.2

HMX04731NA

20

59.4

HMX06031NA

7

25

74.9

HMX07531NA

30

88

HMX08831NA

2
2
2
2
2
2
2

230 Vac
FS
Frame Size
4

5

Horsepower

Drive Rated
NEC Amps

2

Catalog Number

1

4.2

HMX4D232NA

2

6.8

HMX6D832NA

3

9.6

HMX9D632NA

5

15.2

HMX01632NA

7.5

22

HMX02232NA

10

28

HMX02832NA

6

15

42

HMX04232NA

20

54

HMX05432NA

7

25

68

HMX06832NA

30

80

HMX08032NA

2
2
2
2
2
2
2

480 Vac
FS
Frame Size
4

5

6

7

Horsepower

Drive Rated
NEC Amps

2

Catalog Number

1

2.1

HMX2D134NA

2

3.4

HMX3D434NA

3

5.6

HMX5D634NA

5

7.6

HMX7D634NA

7.5

11

HMX01134NA

10

14

HMX01434NA

15

21

HMX02134NA

20

27

HMX02734NA

25

34

HMX03434NA

30

40

HMX04034NA

40

52

HMX05234NA

50

65

HMX06534NA

60

77

HMX07734NA

75

96

HMX09634NA

2
2
2
2
2
2
2
2
2

Notes
For Wiring Diagrams, see Page V6-T2-153.
For NEMA 12 or 3R enclosures, see Catalog Number Selection on Page V6-T2-142.
Call Technical Support for NEMA 3R specifics. Enclosure size and weight differ from NEMA 1 and 12 products.

2
2

Volume 6—Solid-State Motor Control CA08100007E—May 2014 www.eaton.com

V6-T2-143

2.6

Adjustable Frequency Drives
H-Max Series Drives

2

H-Max Series IntelliPass NEMA Type 12—Two Contactor Bypass Standard

2

HMX_

2

208 Vac
FS
Frame Size

Horsepower

Drive Rated
NEC Amps

4

1

4.6

HMX4D641NA

2

7.5

HMX7D541NA

2
2

3

10.6

HMX01141NA

5

16.7

HMX01741NA

7.5

24.2

HMX02541NA

10

30.8

HMX03141NA

6

15

46.2

HMX04741NA

20

59.4

HMX06041NA

7

25

74.9

HMX07541NA

30

88

HMX08841NA

FS
Frame Size

Horsepower

Drive Rated
NEC Amps

Catalog Number

4

1

4.2

HMX4D242NA

2

6.8

HMX6D842NA

5

2
2
2

Catalog Number

2
230 Vac

2
2
2

3

9.6

HMX9D642NA

5

15.2

HMX01642NA

7.5

22

HMX02242NA

10

28

HMX02842NA

2

6

15

42

HMX04242NA

20

54

HMX05442NA

2

7

25

68

HMX06842NA

30

80

HMX08042NA

FS
Frame Size

Horsepower

Drive Rated
NEC Amps

Catalog Number

4

1

2.1

HMX2D144NA

2

3.4

HMX3D444NA

3

5.6

HMX5D644NA

5

7.6

HMX7D644NA

2

5

2

2
480 Vac

2
2
2
2
2

5

2
2

6

2

7

2
2

7.5

11

HMX01144NA

10

14

HMX01444NA

15

21

HMX02144NA

20

27

HMX02744NA

25

34

HMX03444NA

30

40

HMX04044NA

40

52

HMX05244NA

50

65

HMX06544NA

60

77

HMX07744NA

75

96

HMX09644NA

Notes
For Wiring Diagrams, see Page V6-T2-153.
For NEMA 12 or 3R enclosures, see Catalog Number Selection on Page V6-T2-142.
Call Technical Support for NEMA 3R specifics. Enclosure size and weight differ from NEMA 1 and 12 products.

2
2
2
V6-T2-144

Volume 6—Solid-State Motor Control CA08100007E—May 2014 www.eaton.com

Adjustable Frequency Drives
H-Max Series Drives

2.6

H-Max Series IntelliPass NEMA Type 3R—Two Contactor Bypass Standard
HMX_

2

208 Vac
FS
Frame Size
4

5

Horsepower

Drive Rated
NEC Amps

2
Catalog Number

1

4.6

HMX4D651NA

2

7.5

HMX7D551NA

3

10.6

HMX01151NA

5

16.7

HMX01751NA

7.5

24.2

HMX02551NA

10

30.8

HMX03151NA

6

15

46.2

HMX04751NA

20

59.4

HMX06051NA

7

25

74.9

HMX07551NA

30

88

HMX08851NA

2
2
2
2
2
2
2

230 Vac

2

FS
Frame Size

Horsepower

Drive Rated
NEC Amps

Catalog Number

4

1

4.2

HMX4D252NA

5

2

6.8

HMX6D852NA

3

9.6

HMX9D652NA

5

15.2

HMX01652NA

7.5

22

HMX02252NA

10

28

HMX02852NA

6

15

42

HMX04252NA

20

54

HMX05452NA

7

25

68

HMX06852NA

30

80

HMX08052NA

2
2
2
2
2
2
2

480 Vac

2

FS
Frame Size

Horsepower

Drive Rated
NEC Amps

Catalog Number

4

1

2.1

HMX2D154NA

2

3.4

HMX3D454NA

3

5.6

HMX5D654NA

5

6

7

5

7.6

HMX7D654NA

7.5

11

HMX01154NA

10

14

HMX01454NA

15

21

HMX02154NA

20

27

HMX02754NA

25

34

HMX03454NA

30

40

HMX04054NA

40

52

HMX05254NA

50

65

HMX06554NA

60

77

HMX07754NA

75

96

HMX09654NA

2
2
2
2
2
2
2
2
2

Notes
For Wiring Diagrams, see Page V6-T2-153.
For NEMA 12 or 3R enclosures, see Catalog Number Selection on Page V6-T2-142.
Call Technical Support for NEMA 3R specifics. Enclosure size and weight differ from NEMA 1 and 12 products.

2
2
2

Volume 6—Solid-State Motor Control CA08100007E—May 2014 www.eaton.com

V6-T2-145

2.6

Adjustable Frequency Drives
H-Max Series Drives

2

H-Max Series IntelliDisconnect NEMA Type 1—Main Disconnect Standard

2

HMX_

208 Vac
FS
Frame Size

Horsepower

Drive Rated
NEC Amps

Catalog Number

4

1

4.6

HMX4D6A1NA

2

7.5

HMX7D5A1NA

3

11

HMX011A1NA

5

17

HMX017A1NA

7.5

25

HMX025A1NA

10

31

HMX031A1NA

15

47

HMX047A1NA

20

60

HMX060A1NA

25

75

HMX075A1NA

30

88

HMX088A1NA

FS
Frame Size

Horsepower

Drive Rated
NEC Amps

Catalog Number

4

1

4.2

HMX4D2A2NA

2

6.8

HMX6D8A2NA

3

9.6

HMX9D6A2NA

5

15.2

HMX016A2NA

7.5

22

HMX022A2NA

10

28

HMX028A2NA

15

42

HMX042A2NA

20

54

HMX054A2NA

25

68

HMX068A2NA

30

80

HMX080A2NA

FS
Frame Size

Horsepower

Drive Rated
NEC Amps

Catalog Number

4

1

2.1

HMX2D1A4NA

2

2

3.4

HMX3D4A4NA

3

5.6

HMX5D6A4NA

2

5

7.6

HMX7D6A4NA

7.5

11

HMX011A4NA

10

14

HMX014A4NA

15

21

HMX021A4NA

20

27

HMX027A4NA

25

34

HMX034A4NA

30

40

HMX040A4NA

40

52

HMX052A4NA

50

65

HMX065A4NA

60

77

HMX077A4NA

75

96

HMX096A4NA

2
2
2

5

2

6

2

7

2
2

230 Vac

2
2
2
2

5

2
2

6

2

7

2
480 Vac

2
2

2

5

2
2

6

2

7

2
2

Notes
For Wiring Diagrams, see Page V6-T2-153.
For NEMA 12 or 3R enclosures, see Catalog Number Selection on Page V6-T2-142.
Call Technical Support for NEMA 3R specifics. Enclosure size and weight differ from NEMA 1 and 12 products.

2
2
2
V6-T2-146

Volume 6—Solid-State Motor Control CA08100007E—May 2014 www.eaton.com

Adjustable Frequency Drives
H-Max Series Drives

2.6

H-Max Series IntelliDisconnect NEMA Type 12—Main Disconnect Standard
HMX_

2

208 Vac

2

FS
Frame Size

Horsepower

Drive Rated
NEC Amps

Catalog Number

4

1

4.6

HMX4D6B1NA

2

7.5

HMX7D5B1NA

3

11

HMX011B1NA

5

17

HMX017B1NA

7.5

25

HMX025B1NA

5

10

31

HMX031B1NA

6

15

47

HMX047B1NA

20

60

HMX060B1NA

7

25

75

HMX075B1NA

30

88

HMX088B1NA

2
2
2
2
2
2
2

230 Vac

2

FS
Frame Size

Horsepower

Drive Rated
NEC Amps

Catalog Number

4

1

4.2

HMX4D2B2NA

2

6.8

HMX6D8B2NA

3

9.6

HMX9D6B2NA

5

15.2

HMX016B2NA

7.5

22

HMX022B2NA

5

10

28

HMX028B2NA

6

15

42

HMX042B2NA

20

54

HMX054B2NA

7

25

68

HMX068B2NA

30

80

HMX080B2NA

2
2
2
2
2
2
2

480 Vac

2

FS
Frame Size

Horsepower

Drive Rated
NEC Amps

Catalog Number

4

1

2.1

HMX2D1B4NA

2

3.4

HMX3D4B4NA

3

5.6

HMX5D6B4NA

5

7.6

HMX7D6B4NA

7.5

11

HMX011B4NA

10

14

HMX014B4NA

15

21

HMX021B4NA

5

6

7

20

27

HMX027B4NA

25

34

HMX034B4NA

30

40

HMX040B4NA

40

52

HMX052B4NA

50

65

HMX065B4NA

60

77

HMX077B4NA

75

96

HMX096B4NA

2
2
2
2
2
2
2
2
2

Notes
For Wiring Diagrams, see Page V6-T2-153.
For NEMA 12 or 3R enclosures, see Catalog Number Selection on Page V6-T2-142.
Call Technical Support for NEMA 3R specifics. Enclosure size and weight differ from NEMA 1 and 12 products.

2
2
2

Volume 6—Solid-State Motor Control CA08100007E—May 2014 www.eaton.com

V6-T2-147

2.6

Adjustable Frequency Drives
H-Max Series Drives

2

H-Max Series IntelliDisconnect NEMA Type 3R—Main Disconnect Standard

2

HMX_

208 Vac
FS
Frame Size

Horsepower

Drive Rated
NEC Amps

Catalog Number

4

1

4.6

HMX4D6C1NA

2

7.5

HMX7D5C1NA

3

11

HMX011C1NA

5

17

HMX017C1NA

7.5

25

HMX025C1NA

10

31

HMX031C1NA

15

47

HMX047C1NA

20

60

HMX060C1NA

25

75

HMX075C1NA

30

88

HMX088C1NA

FS
Frame Size

Horsepower

Drive Rated
NEC Amps

Catalog Number

4

1

4.2

HMX4D2C2NA

2

6.8

HMX6D8C2NA

3

9.6

HMX9D6C2NA

5

15.2

HMX016C2NA

7.5

22

HMX022C2NA

10

28

HMX028C2NA

15

42

HMX042C2NA

20

54

HMX054C2NA

25

68

HMX068C2NA

30

80

HMX080C2NA

FS
Frame Size

Horsepower

Drive Rated
NEC Amps

Catalog Number

4

1

2.1

HMX2D1C4NA

2

2

3.4

HMX3D4C4NA

3

5.6

HMX5D6C4NA

2

5

7.6

HMX7D6C4NA

7.5

11

HMX011C4NA

10

14

HMX014C4NA

15

21

HMX021C4NA

20

27

HMX027C4NA

25

34

HMX034C4NA

30

40

HMX040C4NA

40

52

HMX052C4NA

50

65

HMX065C4NA

60

77

HMX077C4NA

75

96

HMX096C4NA

2
2
2

5

2

6

2

7

2
2

230 Vac

2
2
2
2

5

2
2

6

2

7

2
480 Vac

2
2

2

5

2
2

6

2

7

2
2

Notes
For Wiring Diagrams, see Page V6-T2-153.
For NEMA 12 or 3R enclosures, see Catalog Number Selection on Page V6-T2-142.
Call Technical Support for NEMA 3R specifics. Enclosure size and weight differ from NEMA 1 and 12 products.

2
2
2
V6-T2-148

Volume 6—Solid-State Motor Control CA08100007E—May 2014 www.eaton.com

Adjustable Frequency Drives
H-Max Series Drives

2.6

Onboard Network Communications
Johnson Controls
Metasys N2
H-Max Series provides
communication between the
drive and a Johnson Controls
Metasys™ N2 network. With
this connection, the drive can
be controlled, monitored and
programmed from the
Metasys system. N2 can be
selected and programmed by
the drive keypad.

2
BACnet

Modbus RTU

H-Max Series provides
communication to BACnet
networks. Data transfer is
master-slave/token passing
(MS/TP) RS-485.

H-Max Series provides
communication to Modbus
RTU RS-485 as a slave on a
Modbus network. Other
communication parameters
include an address range
from 1 to 247; a parity of
None, Odd or Even; and the
stop bit is 1.

BACnet IP
100Base-T interface.

2

.

2
2
2
2

Modbus TCP

2

Ethernet based protocol.

2
2

H-Max Series Option Board Kits Available for Slots D and E
The H-Max Series drives can
accommodate a wide
selection of expander and
adapter option boards to
customize the drive for your

application needs. The drive’s
control unit is designed to
accept a total of two option
boards.

2

The H-Max Series factoryinstalled standard board
configuration includes an
I/O board and a relay
output board.

2
2

Option Boards Mounted in Slots D and E
Option Kit Description

Option Kit
Catalog Number

6 x DI /DO, each digital input can be individually programmed as digital output

XMX-IO-B1-A

1RO Form C (NO/NC), 1RO Form A (NO), 1 thermistor

XMX-IO-B2-A

1 x AI, 2 x AO (isolated)

XMX-IO-B4-A

3 x RO Form A (NO)

XMX-IO-B5-A

1RO Form A (NO), 5DI 42–240 Vac input

XMX-IO-B9-A

LonWorks

XMX-COM-C4-A

1 x AO, 1 x DO, 1 x RO

XMX-IO-BF-A

2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2

Volume 6—Solid-State Motor Control CA08100007E—May 2014 www.eaton.com

V6-T2-149

2.6

Adjustable Frequency Drives
H-Max Series Drives

2

Extended I/O Options in Slot D and E

2

Description

Suffix
Number

6 x DI /DO, Each digital input can be individually
programmed as digital output

B1

1RO (NC/NO), 1RO (NO), 1 Thermistor

B2

2

1 x AI, 2 x AO (isolated)

B4

3 x RO

B5

2

1RO (NO), 5 DI 42–240 Vac input

B9

Expander IO, 1 AO, 1 DO, 1 RO

BF

2

2
2

Optional Communications in Slot D and E

2

Description

Suffix
Number

LonWorks

C4

2
2

IntelliDisconnect Options

2

Description

Suffix
Number

Pilot lights (Power ON, RUN, Fault)

L3

Fused drive isolation (cannot be used with PE)

P3

Output contactor (cannot be used with P3)

PE

Space heater w/transformer (Type 3R only)

SA

2
2
2
2

IntelliPass Bypass Options

2

Description

Suffix
Number

2

Pilot lights (Power ON, RUN, Fault)

L4

Fused drive isolation (can not be used with P6)

P3

2

Third contactor drive isolation (cannot be used with P3 or IS)

P6

Manual bypass switch located on front door

M1

2

Space heater w/transformer (Type 3R only)

SA

2

Auxiliary contacts

K9

Isolation switch

IS

2
2
2

Standard Onboard Communications
Suffix
Number

Description
RS-485 Communications

2

BACnet MS/TP = Master slave/token protocol (Universal BACnet) RS-485

BACnet

Modbus RTU RS-485, ASCII or RTU, remote terminal unit 32 nodes

Modbus

2

Johnson Controls Metasys N2 network

N2

2
2

Onboard Ethernet-Based Communications
(port left side of keypad)
BACnet/IP Ethernet industrial protocol

BACnet

Modbus/TCP Transmission control protocol (Ethernet-based)

Modbus

2
2
2
V6-T2-150

Volume 6—Solid-State Motor Control CA08100007E—May 2014 www.eaton.com

2.6

Adjustable Frequency Drives
H-Max Series Drives

Technical Data and Specifications

2

Primary Design Features
Description

IntelliPass

IntelliDisconnect

Description

IntelliPass

IntelliDisconnect

CB MMP

Standard

Standard

Isolation switch

Optional

N/A

2 contactor bypass

Standard

N/A

Top entry (power)

Standard

Standard

Electrical interlock

Standard

N/A

Bottom entry (power)

Standard

Standard

Third contactor (isolation)

Optional

N/A

Output contactor

Standard

Optional

2
2
2
2
2

H-Max Series Drives
Description

Specification

Description

Input Ratings

Specification

2

Standards

Input voltage (Vin)

208, 230, 480 Vac, –10%/+10%

Input frequency (fin)

50/60 Hz (variation up to 47–66 Hz)

Connection to power

Once per minute or less (typical operation)

Short-circuit withstand
rating

65 kAIC combination

EMC

Immunity: Fulfills all EMC immunity requirements;
Emissions: EN 61800-3, LEVEL H (EMC C2)

2

Emissions

EMC level dependent—
+EMC 2: EN61800-3 (2004) Category C2
Delivered with Class C2 EMC filtering as default.

2
2

Control Connections

Output Ratings
Output voltage

0 to Vin/Uin line voltage in

Continuous output current

Ambient temperature max. 104°F (40°C)

IL overload

1.1 x IL (1 min./10 min.)

Overload current

110% (1 min./10 min.)

Initial output current

150% for two seconds

Output frequency

0 to 320 Hz

Frequency resolution

0.01 Hz

Analog input voltage

0 to 10V, R = 200 kohms differential
Resolution 0.1%; Accuracy ±1%
DIP switch selection (voltage/current)

2

Analog input current

0(4) to 20 mA; Ri –250 ohms differential

Digital inputs (6)

Positive or negative logic; 18 to 30 Vdc

2

Auxiliary voltage

+24V ±10%, max. 250 mA

Output reference voltage

+10V +3%, max. load 10 mA

Analog output

0–10V, 0(4) to 20 mA; RL max. 500 ohms;
Resolution 10 bit; Accuracy ±2%;
DIP switch selection (voltage/current)

Control Characteristics

2
2

Control method

Frequency control (V/f) open loop sensorless vector control

Relay outputs

3 programmable, 2 Form C, 1 Form A relay outputs
Switching capacity: 24 Vdc/8A, 250 Vac/8A, 125 Vdc/0.4A

Switching frequency

1–310 amps; adjustable with parameter 2.6.9
FS4–FS7: default 6 kHz

Hard wire jumper

Between terminal 6 and 10 factory default

Frequency reference

Analog input: Resolution 0.1% (10-bit), accuracy ±1%
Panel reference: Resolution 0.01 Hz

DIP switch setting default

RS-485 = off
A01 = current
A12 = current
A11 = voltage

2
2
2
2

Field weakening point

8 to 320 Hz

Acceleration time

0.1 to 3000 seconds

Protections

Deceleration time

0.1 to 3000 seconds

Overcurrent protection

Braking torque

DC brake: 30% x Tn

Overvoltage protection

Yes

DC bus regulation anti-trip

Yes (accelerates or decelerates the load)

Undervoltage protection

Yes

2

Earth fault protection

Yes (in case of earth fault in motor or motor cable,
only the frequency converter is protected)

2
2

Ambient Conditions
Ambient operating
temperature

FS4–FS7: 14°F (–10°C), no frost to 104°F (40°C)
(Drive can operate at 122°F (50°C)

Storage temperature

–40° to 158°F (–40° to 70°C)

Relative humidity

0 to 95% RH, noncondensing, non-corrosive, no dripping water

Input phase supervision

Yes (trips if any of the input phases are missing)

Air quality

Chemical vapors: IEC 60721-3-3, unit in operation, Class 3C2;
Mechanical particles: IEC 60721-3-3, unit in operation, Class 3S2

Motor phase supervision

Yes (trips if any of the output phases are missing)

Altitude

100% load capacity (no derating) up to 3280 ft (1000m);
1% derating for each 328 ft (100m) above 3280 ft (1000m);
max. 9842 ft (3000m); 380–480V

2

Yes

2

2

Overtemperature protection Yes
Motor overload protection

Yes

Motor stall protection

Yes

Vibration

FS4–FS7: IEC 60068-2-6, 10–150 Hz
Displacement amplitude = 1 mm peak-to-peak from 10–15.8 Hz
Max. acceleration amplitude = 1G peak from 15.8–150 Hz

Motor underload protection Yes
Short-circuit protection

Yes

Shock

FS4–FS7: IEC 60068-2-27, 15G peak acceleration at 11 ms
duration, 1/2-sine. ISTA 1A Certified

Surge protection

Yes (varistor input)

NEMA Type 1/IP21 or NEMA Type 12/IP54
(keypad required for IP54/Type 12)

Conformed coated
(varnished) board

Yes (prevents corrosion)

Enclosure class

2
2
2
2
2
2

Volume 6—Solid-State Motor Control CA08100007E—May 2014 www.eaton.com

V6-T2-151

2.6

Adjustable Frequency Drives
H-Max Series Drives

2

Wiring Diagrams

2

Control Input/Output, PID Application

Optional

2

Circuit
Breaker

L1
L2

2
2
2

L3

Resistor

2

Factory
Jumper

2
2

2
2
2
2

4

AI–2+

5

AI–2–

6

24Vout

V (T2)

Factory Default Signal
Reference Output
Analog Input Voltage (Range 0–10 Vdc)
(can be programmed to current 4–20 mA)
Analog Output Common (Ground)
Analog Input Current (Range 4–20 mA)
(can be programmed to voltage 0–10 Vdc)
PI Setpoint or Feedback
Analog Input Common
PI Setpoint or Feedback
Control Voltage Output (0.1A max.)

GND

I/O Ground

8

DIN1

START/STOP (Contact closed = start)

9

DIN2

External Fault (Closed = fault)
Run Interlock Permissive IP Interlock
(Closed = OK)
DIN1–DIN6 Common

12 24Vout

Control Voltage Output (0.1A max.)

13 GND

I/O Ground

14 DIN4

Speed Select 0–100% (Preset speed)

15 DIN5

Fire Mode (Contact closed = fire mode)

16 DIN6

Force Bypass (Contact closed = bypass)

17 CMB

DIN1–DIN6 Common

18 AO–1+

Output Frequency (0–20 mA)

19 AO–1–

Analog Output Common (Ground)

30 24 Vdcin

Auxiliary Input Voltage

A

DATA-

RS-485 DATA-

B

DATA+

RS-485 DATA+
Relay Board 1
Default Signal
RO1 Bypass Run

24
25

Motor

W (T3)

7

COM

U (T1)

Test

RO2 Drive Run

OFF
VOLTAGE
VOLTAGE
VOLTAGE

ON
CURRENT
CURRENT
CURRENT

RS485
AO1
AI2
AI1

Terminal Block Layout

Programmable BACnet,
Modbus, FLN, N2
Slot B

23

2

24 Vdc/8A
250 Vac/8A
125 Vdc/0.4A

21

22

23

24

25

26

32

33

RO1

RO1

RO1

RO2

RO2

RO2

RO3

RO3

NC

COM

NO

NC

COM

NO

COM

NO

30

A

12

13

24 Vdc GND
out

14

15

16

17

18

DI4

DI5

DI6

COM
DI1–6

AO1+

19

1

2

3

4

5

6

7

8

9

10

11

+10
Vdc

AI1+

AI1–

AI2+

AI2–

24 Vdc
out

GND

DI1

DI2

DI3

COM
DI1–6

32

2

33

RO3 Fault

Standards
●
Digital inputs D1–D6, relay
out, analog in/out are freely
programmed
●
The user can assign a
single input to multiple
functions

2
V6-T2-152

Includes
Six digital input
●
Two analog input
●
One analog output
●
Three relay output
●
RS-485
●
Ethernet
●

B

AO1– 24 Vdc RS-485 RS-485
in
Data– Data+

26

2

2

Vin

22

2

2

AI–1+

3

21

2

2

2

Three-Phase
Output

Optional
Resistor

Factory Jumper
External Interlock

Reliability
Pretested components
●
Conformal coated
(varnished) boards
●
40°C rated
●
110% overload for one
minute
●
Eaton Electrical Services &
Systems national network
of AF drive specialists
●

Volume 6—Solid-State Motor Control CA08100007E—May 2014 www.eaton.com

Slot E __________________

Analog

2

2

+10V

11

2

2

1

10 DIN3

2

DB R+
Chopper R-

5% DC Link

Reactor
Three-Phase Input
Input
(Single-Phase not available)

Slot A
Terminal

2
2

BACnet/IP Ethernet Industrial Protocol
Modbus/TCP Transmission Control Protocol (Ethernet Based)

Slot D __________________

RJ-45

2

Adjustable Frequency Drives
H-Max Series Drives

H-Max Series IntelliPass

2.6

H-Max Series IntelliDisconnect Power Wiring

2

Incoming Power
L2
L1
L3

Incoming Power
L2
L1
L3

2

Bypass

2

Circuit
Breaker

Circuit
Breaker

2
2
2

Optional Fuse

Optional Fuse
or
Drive Input
Contactor

2
2

To Drive Input
L1

L2

L3

2

To Drive Output

To Drive Input

2

U(T1) V(T2)W(T3)
To Drive Output

2

Optional
Output
Contactor

U(T1) V(T2)W(T3)
Output
Contactor

2
2

Bypass
Contactor

2

V(T2)
U(T1)

W(T3)

2

Motor

2

Overload
Relay

2
2

V(T2)
U(T1)

W(T3)

2

Motor

2
2
2
2
2
2
2
2
2
2
2
Volume 6—Solid-State Motor Control CA08100007E—May 2014 www.eaton.com

V6-T2-153

2.6
2
2

Adjustable Frequency Drives
H-Max Series Drives

Dimensions
Approximate Dimensions in Inches (mm)
H-Max Series IntelliPass and IntelliDisconnect Drives

2

W1

H3

2

D1

2
2
2
2
2
2

H4
H1

H2

2
2
2
2
2
2

W3

W2

C

D2

2

Consult factory or use manual for final dimensions.

2

Frame
Size

Voltage

Horsepower (IL)

H1

H2

H3

H4

C

W1

W2

W3

D1

D2

2

FS4

208

1–3
1–3

30.00
(762.0)

29.41
(747.1)

0.25
(6.35)

31.00
(787.4)

3.00
(76.2)

7.88
(200.2)

6.25
(158.8)

0.75
(19.1)

12.49
(317.2)

10.36
(263.1)

45 (20.41)

230
480

1–7.5

208

5–10
5–10

37.00
(939.8)

36.72
(932.7)

0.25
(6.35)

38.31
(973.0)

3.00
(76.2)

9.60
(243.8)

7.97
(202.4)

0.75
(19.1)

15.35
(390.0)

13.22
(335.8)

57.5 (26.10)

230

45.45
(1154.4)

44.81
(1138.2)

0.25
(6.35)

46.4
(1178.6)

4.00
(101.6)

11.44
(290.6)

9.75
(247.6)

0.75
(19.1)

15.80
(401.3)

13.67
(347.2)

98.0 (44.45)

58.51
(1486.2)

57.87
(1470.0)

0.25
(6.35)

59.46
(1510.3)

5.00
(127.0)

14.52
(368.8)

12.83
(325.9)

0.75
(19.1)

15.68
(398.3)

13.72
(348.5)

165.0 (74.84)

2
2
2

FS5

FS6

2
2
2
2

FS7

480

10–20

208

15–20

230

15–20

480

25–40

208

25–30

230

25–30

480

50–75

Note: C distance is spacing required to mount multiple drives.

2
2
2
2
V6-T2-154

Volume 6—Solid-State Motor Control CA08100007E—May 2014 www.eaton.com

Weight in
Lbs (kg)

Adjustable Frequency Drives
H-Max Series Drives

2.6

Approximate Dimensions in Inches (mm)

2

Enclosure Box A NEMA Type 3R
W

2

D

2
2
2
2
2

H

2

H1 H2 H3

2
2
2
2

W2
W1

W3

D2

D1

2

0.44 (11.2)
Mounting
Holes
(4 Places)

2
2
2
2
2
2
2

Voltage
AC

hp
(IL)

H

H1

H2

H3

W

W1

W2

W3

D

D1

D2

33.00
(838.2)

31.36
(796.5)

29.67
(753.6)

25.35
(643.9)

21.05
(534.7)

16.92
(429.8)

15.30
(388.6)

2.07
(52.6)

17.24
(437.9)

16.26
(413.0)

3.31
(84.1)

Approx.
Weight
Lbs (kg)

Approx.
Shipping Weight
Lbs (kg)

170 (77)

215 (98)

Three-Phase
208V

1–10

230V

1–10

480V

1–20

2
2
2
2
2
2
2
2
2
2

Volume 6—Solid-State Motor Control CA08100007E—May 2014 www.eaton.com

V6-T2-155

2.6
2
2

Adjustable Frequency Drives
H-Max Series Drives

Approximate Dimensions in Inches (mm)
Enclosure Box B NEMA Type 3R
W

D

2
2
2
2
2
2
2

H2
H

H1

2

H3

2
2
2
2
2
2

W2
W1

W3

D1

D2
0.44 (11.2)
Mounting
Holes
(4 Places)

2
2
2
2
2
2
2
2
2
2
2

Voltage
AC

hp
(IL)

H

H1

H2

H3

W

W1

W2

W3

D

D1

D2

46.09
(1170.7)

44.45
(1129.0)

42.77
(1086.4)

36.35
(923.3)

26.31
(668.3)

20.92
(531.4)

19.30
(490.2)

2.69
(68.3)

17.74
(450.6)

16.76
(425.7)

3.31
(84.1)

Approx.
Weight
Lbs (kg)

Approx.
Shipping Weight
Lbs (kg)

235 (107)

290 (132)

Three-Phase
208V

15

230V

15

480V

25–40

2
2
2
V6-T2-156

Volume 6—Solid-State Motor Control CA08100007E—May 2014 www.eaton.com

2.6

Adjustable Frequency Drives
H-Max Series Drives

Approximate Dimensions in Inches (mm)

2

Enclosure Box C NEMA Type 3R
0.44 (11.2)
Mounting Holes
(4 Places)
W

W
W2

D

2

0.44 (11.2)
Mounting Holes
(4 Places)
D

2
2
2
2
2

H1 H2
H3

H

2

H2
H3

2
2
2
2

W2
W1
W3

D2

W1

D1

2

D1
D2

2
2
2
2

Voltage
AC

hp
(IL)

H

H1

H2

H3

W

W1

W2

W3

D

D1

D2

Approx.
Weight
Lbs (kg)

2

1

2

Three-Phase
208

20–30

230

20–30

480

50–75

58.09
(1475.5)

56.45
(1433.8)

54.77
(1391.2)

48.35
(1228.1)

37.73
(958.3)

30.92
(785.4)

29.30
(744.2)

3.34
(84.8)

17.74
(450.6)

16.77
(426.0)

3.31
(84.1)

2
2

Note
1 Consult factory.

2
2
2
2
2
2
2
2
2
Volume 6—Solid-State Motor Control CA08100007E—May 2014 www.eaton.com

V6-T2-157

2.7
2

Adjustable Frequency Drives
SPX9000 Drives

Contents

SPX9000 Drives

Description

2

SPX9000 Drives
Features and Benefits . . . . . . . . . . . . . . . . . . .
Standards and Certifications . . . . . . . . . . . . . .
Catalog Number Selection . . . . . . . . . . . . . . . .
Product Selection . . . . . . . . . . . . . . . . . . . . . . .
Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . .
Options . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Replacement Parts . . . . . . . . . . . . . . . . . . . . . .
Technical Data and Specifications . . . . . . . . . .
Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . .

2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2

Product Description
The SPX9000 Series
Adjustable Frequency Drives
from Eaton’s Electrical Sector
are specifically designed
for high performance
applications. Equipped with
high processing power, the
SPX9000 can use information
from an encoder or a resolver
in order to provide very
precise motor control.
Sensorless vector and simple
frequency control are also
supported. Typical
applications requiring high
performance are: masterslave drives, positioning
applications, winder tension
control and synchronization.

The SPX9000 supports fast
drive-to-drive communication.
It also offers an integrated
data logger functionality for
analysis of dynamic events
without the need of additional
hardware. Simultaneous fast
monitoring of several drives
can be done by using the
9000Xdrive tool and CAN
communication. In
applications where reliability
and quality are essential for
high-performance, the
SPX9000 is the logical choice.

The Eaton family of drives
includes DA1, DC1, H-Max,
M-Max, SVX9000 and
SPX9000. 9000X Series drive
ratings are rated for either
high overload (IH) or low
overload (IL). IL indicates
110% overload capacity for
1 minute out of 10 minutes.
IH indicates 150% overload
capacity for 1 minute out of
10 minutes.

The core of the SPX9000
is a fast microprocessor,
providing high dynamic
performance for applications
where good motor handling
and reliability are required.
It can be used both in open
loop applications as well
as in applications requiring
encoder feedback.

2
2
2
2
2
V6-T2-158

Volume 6—Solid-State Motor Control CA08100007E—May 2014 www.eaton.com

Page
V6-T2-159
V6-T2-159
V6-T2-160
V6-T2-161
V6-T2-166
V6-T2-167
V6-T2-174
V6-T2-183
V6-T2-184

Adjustable Frequency Drives
SPX9000 Drives

2.7

Features and Benefits
●

●

●

●

●

●

●

●

●

●

●

●

●

●

●

Speed error <0.01%,
depending on the encoder
Incremental or absolute
encoder support
Encoder voltages of 5V
(RS-422), 15V or 24V,
depending on the option
card
Full torque control at all
speeds, including zero
Torque accuracy <2%;
<5% down to zero speed
Starting torque >200%,
depending on motor and
drive sizing
Integrated datalogger for
system analysis
Fast multiple drive
monitoring with PC
Full capability for master/
slave configurations
High-speed bus (12 Mbit/s)
for fast inter-drive
communication
High-speed applications
(up to 7200 Hz) possible
Robust design—proven
500,000 hours MTBF
Integrated 3% line reactors
standard on drives from
FR4 through FR9
Line reactor is included but
is separated from chassis
EMI/RFI Filters H standard
up to 200 hp IH 480V,
100 hp IH 230V

●

●

●

●

●

●

●

●

Simplified operating menu
allows for typical
programming changes,
while programming mode
provides control of
everything
Quick Start Wizard built
into the programming of
the drive ensures a smooth
start-up
Keypad can display up to
three monitored
parameters simultaneously
LOCAL/REMOTE operation
from keypad
Copy/paste function allows
transfer of parameter
settings from one drive to
the next
Standard NEMA Type 12/
IP54 keypad on all drives
Hand-held auxiliary 240
power supply allows
programming/monitoring
of control module without
applying full power to the
drive
The SPX can be flexibly
adapted to a variety of
needs using our preinstalled “Seven in One”
precision application
programs consisting of:
●
Basic
●
Standard
●
Local/remote
●
Multi-step speed control
●
PID control
●
Multi-purpose control
●
Pump and fan control
with auto change

●

●

●

●

●

●

●

2

Additional I/O and
communication cards
provide plug and play
functionality
I/O connections with
simple quick connection
terminals
Control logic can be
powered from an external
auxiliary control panel,
internal drive functions and
fieldbus if necessary
Brake chopper standard
from: 1–30 hp/380–500V
3/4–15 hp/208–230V
NEMA Type 1/IP21
enclosures available Frame
Sizes FR4–FR11, NEMA
Type 12/IP54 enclosures
available Frame Sizes FR4–
FR10 (FR10 and FR11
freestanding drives)
Open chassis FR10 and
greater
Standard option board
configuration includes an
A9 I/O board and an A2
relay output board installed
in slots A and B

2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2

Standards and Certifications
Product
●
IEC 61800-2
Safety
●
UL 508C

2
EMC (at default settings)
●
Immunity: Fulfills all EMC
immunity requirements;
Emissions: EN 61800-3,
LEVEL H

●
●

2

UL Listed
CE

2
2
2
2
2
2

Volume 6—Solid-State Motor Control CA08100007E—May 2014 www.eaton.com

V6-T2-159

2.7
2
2

Adjustable Frequency Drives
SPX9000 Drives

Catalog Number Selection
SPX9000 Adjustable Frequency Drives

SPX 010 A 1 – 4 A 1 B 1

2
2
2
2
2
2
2
2
2
2
2

2

Voltage Rating
2 = 230V (208–240)
4 = 480V (380–500)
5 = 575V (525–690)

2
2

2
2
2

Board Modifications
1 = Standard boards
2 = Conformal (varnished) coating 4

Enclosure 3
0 = Chassis
1 = NEMA Type 1/IP21
2 = NEMA Type 12/IP54

2

2

Horsepower Rating
3/4
125 = 125
1
150 = 150
1-1/2
250 = 250
2
300 = 300
3
350 = 350
5 (IL)
400 = 400
500 = 500
5
550 = 550
7-1/2 (IL)
600 = 600
7-1/2
650 = 650
10
700 = 700
15
800 = 800
20
900 = 900
25
H10 = 1000
30
H12 = 1200
40
H13 = 1350
50
H15 = 1500
60
H16 = 1600
75
H20 = 2000
100
AFD Software Series
A = Standard software

2

2

Options
Options appear in alphabetical order.
Extended I/O Card Options
A3 = 2 RO, Therm
A4 = Encoder low volt +5V/15V24V
A5 = Encoder high volt +15V/24V
A7 = Double Encoder
A8 = 6 DI, 1 DO, 2 AI, 1AO
AE = 3 DI (Encoder 10–24V), Out +15V/+24V 2 DO (pulse + direction)
B1 = 6 DI, 1 ext +24 Vdc/EXT +24 Vdc
B2 = 1 RO (NC-NO), 1 RO (NO), 1 therm
B4 = 1 AI (mA isolated), 2 AO (mA isolated), 1 ext +24 Vdc/EXT + 24 Vdc
B5 = 3 RO (NO)
B8 = 1 ext +24 Vdc/EXT +24 Vdc, 3 Pt100
B9 = 1 RO (NO), 5 DI 42–240 Vac input
BB = SPI, absolute encoder
Communication Cards
CA = Johnson Controls N2
C5 = PROFIBUS DP (D9 connector)
CI = Modbus TCP
C6 = CANopen (slave)
CJ = BACnet
C7 = DeviceNet
CQ = EtherNet/IP
C8 = Modbus (D9 type connector)
C2 = Modbus
D1 = Adapter—SPX only
C3 = PROFIBUS DP
D2 = Adapter—SPX only
C4 = LonWorks
D3 = RS-232 with D9 connection

Product Family
SPX = Open drives

F07 =
001 =
F15 =
002 =
003 =
004 =
005 =
006 =
007 =
010 =
015 =
020 =
025 =
030 =
040 =
050 =
060 =
075 =
100 =

_ _ _ _ _ _

Brake Chopper Options 2
N = No brake chopper circuit
B = Internal brake chopper circuit

Keypad
A = Alphanumeric

Input Options 1
1 = Three-phase, EMC H
2 = Three-phase, EMC N
4 = Three-phase, EMC L

Notes
1 All 230V drives and 480V drives up to 200 hp (I ) are only available with input option 1 (EMC level H). 480V drives 250 hp (I ) or larger are
H
H
available with input option 2 (EMC level N). 575V drives 200 hp (IH) or larger are available with input option 2. 575V drives up to 150 hp (IH)
are available with input option 4 (EMC level L). 480V and 690V freestanding drives are available with input option 4 (EMC level L).
2 480V drives up to 30 hp (I ) are only available with brake chopper option B. 480V drives 40 hp (I ) or larger come standard with brake
H
H
chopper option N. 230V drives up to 15 hp (IH) are only available with brake chopper option B. 230V drives 20 hp and larger come standard
with brake chopper option N. All 575V drives come standard without brake chopper option (N). N = No brake chopper.
3 480V drives 250–350 hp (I ) and 690V drives 200–300 hp (I ) are available with enclosure style 0 (chassis). 480V and 690V FR10
H
H
freestanding drives are available with 1 (NEMA Type 1/IP21) or 2 (NEMA Type 12/IP54). FR11 freestanding drives are only available with
enclosure style 1 (NEMA Type 1/IP21).
4 Factory promise delivery. Consult sales office for availability.

2
2
2
2
2
2
2
V6-T2-160

Volume 6—Solid-State Motor Control CA08100007E—May 2014 www.eaton.com

Adjustable Frequency Drives
SPX9000 Drives

2.7

Product Selection

2

230V Drives

2

SPX9000 Open Drives

208–240V, NEMA Type 1/IP21 Drives
Frame
Size

hp (IH)

Current (IH)

hp (IL)

Current (IL)

Catalog Number

FR4

3/4

3.7

1

4.8

SPXF07A1-2A1B1

FR5

FR6

FR7

FR8

FR9

1

4.8

1-1/2

6.6

SPX001A1-2A1B1

1-1/2

6.6

2

7.8

SPXF15A1-2A1B1

2

7.8

3

11

SPX002A1-2A1B1

3

11

—

12.5

SPX003A1-2A1B1

—

12.5

5

17.5

SPX004A1-2A1B1

5

17.5

7-1/2

25

SPX005A1-2A1B1

7-1/2

25

10

31

SPX007A1-2A1B1

10

31

15

48

SPX010A1-2A1B1

15

48

20

61

SPX015A1-2A1B1

20

61

25

75

SPX020A1-2A1N1

25

75

30

88

SPX025A1-2A1N1

30

88

40

114

SPX030A1-2A1N1

40

114

50

140

SPX040A1-2A1N1

50

140

60

170

SPX050A1-2A1N1

60

170

75

205

SPX060A1-2A1N1

75

205

100

261

SPX075A1-2A1N1

100

261

—

—

SPX100A1-2A1N1

2
2
2
2
2
2
2
2
2
2
2
2
2

208–240V, NEMA Type 12/IP54 Drives
Frame
Size
FR4

FR5

FR6

FR7

FR8

FR9

hp (IH)

Current (IH)

hp (IL)

Current (IL)

Catalog Number

3/4

3.7

1

4.8

SPXF07A2-2A1B1

1

4.8

1-1/2

6.6

SPX001A2-2A1B1

1-1/2

6.6

2

7.8

SPXF15A2-2A1B1

2

7.8

3

11

SPX002A2-2A1B1

3

11

—

12.5

SPX003A2-2A1B1

—

12.5

5

17.5

SPX004A2-2A1B1

5

17.5

7-1/2

25

SPX005A2-2A1B1

7-1/2

25

10

31

SPX007A2-2A1B1

10

31

15

48

SPX010A2-2A1B1

15

48

20

61

SPX015A2-2A1B1

20

61

25

75

SPX020A2-2A1N1

25

75

30

88

SPX025A2-2A1N1

30

88

40

114

SPX030A2-2A1N1

40

114

50

140

SPX040A2-2A1N1

50

140

60

170

SPX050A2-2A1N1

60

170

75

205

SPX060A2-2A1N1

75

205

100

261

SPX075A2-2A1N1

100

261

—

—

SPX100A2-2A1N1

2
2
2
2
2
2
2
2
2
2
2
2
2
2
2

Volume 6—Solid-State Motor Control CA08100007E—May 2014 www.eaton.com

V6-T2-161

2.7
2

480V Drives

2

SPX9000 Open Drives

Adjustable Frequency Drives
SPX9000 Drives

380–500V, NEMA Type 1/IP21 Drives
Frame
Size

2

FR4

hp (IH)

Current (IH)

hp (IL)

Current (IL)

Catalog Number

1

2.2

1-1/2

3.3

SPX001A1-4A1B1

2

1-1/2

3.3

2

4.3

SPXF15A1-4A1B1

2

4.3

3

5.6

SPX002A1-4A1B1

2

3

5.6

5

7.6

SPX003A1-4A1B1

5

7.6

—

9

SPX005A1-4A1B1

—

9

7-1/2

12

SPX006A1-4A1B1

7-1/2

12

10

16

SPX007A1-4A1B1

10

16

15

23

SPX010A1-4A1B1

15

23

20

31

SPX015A1-4A1B1

20

31

25

38

SPX020A1-4A1B1

25

38

30

46

SPX025A1-4A1B1

30

46

40

61

SPX030A1-4A1B1

40

61

50

72

SPX040A1-4A1N1

50

72

60

87

SPX050A1-4A1N1

60

87

75

105

SPX060A1-4A1N1

75

105

100

140

SPX075A1-4A1N1

100

140

125

170

SPX100A1-4A1N1

125

170

150

205

SPX125A1-4A1N1

150

205

200

261

SPX150A1-4A1N1

200

245

250

300

SPX200A1-4A1N1

2
2

FR5

2

FR6

2
2

FR7

2
2

FR8

2
FR9

2
2

380–500V, NEMA Type 1/IP21 Freestanding Drives

2

Frame
Size

2

FR10

2
2

FR11

2
2

hp (IH)

Current (IH)

hp (IL)

Current (IL)

Catalog Number

250

330

300

385

SPX250A1-4A4N1

300

385

350

460

SPX300A1-4A4N1

350

460

400

520

SPX350A1-4A4N1

400

520

500

590

SPX400A1-4A4N1

500

590

550

650

SPX500A1-4A4N1

550

650

600

730

SPX550A1-4A4N1

Note
Integrated fuses as standard. Limited option selection available; 115V transformer (KB), light kit (L1), HOA (K4),
speed potentiometer w/HOA (K2), Disconnect switch (P2). See Freestanding Option selection on Page V6-T2-173.

2
2
2
2
2
2
2
2
2
V6-T2-162

Volume 6—Solid-State Motor Control CA08100007E—May 2014 www.eaton.com

Adjustable Frequency Drives
SPX9000 Drives

SPX9000 Open Drives

2.7

380–500V, NEMA Type 12/IP54 Drives

2

Frame
Size

hp (IH)

Current (IH)

hp (IL)

Current (IL)

Catalog Number

FR4

1

2.2

1-1/2

3.3

SPX001A2-4A1B1

1-1/2

3.3

2

4.3

SPXF15A2-4A1B1

2

4.3

3

5.6

SPX002A2-4A1B1

3

5.6

5

7.6

SPX003A2-4A1B1

5

7.6

—

9

SPX005A2-4A1B1

—

9

7-1/2

12

SPX006A2-4A1B1

7-1/2

12

10

16

SPX007A2-4A1B1

10

16

15

23

SPX010A2-4A1B1

15

23

20

31

SPX015A2-4A1B1

20

31

25

38

SPX020A2-4A1B1

25

38

30

46

SPX025A2-4A1B1

30

46

40

61

SPX030A2-4A1B1

40

61

50

72

SPX040A2-4A1N1

50

72

60

87

SPX050A2-4A1N1

60

87

75

105

SPX060A2-4A1N1

75

105

100

140

SPX075A2-4A2N1

100

140

125

170

SPX100A2-4A1N1

125

170

150

205

SPX125A2-4A1N1

150

205

200

261

SPX150A2-4A1N1

200

245

250

300

SPX200A2-4A1N1

FR5

FR6

FR7

FR8

FR9

2
2
2
2
2
2
2
2
2
2
2
2
2
2

380–500V, NEMA Type 12/IP54 Freestanding Drives
Frame
Size

hp (IH)

Current (IH)

hp (IL)

Current (IL)

Catalog Number

FR10

250

330

300

385

SPX250A2-4A4N1

300

385

350

460

SPX300A2-4A4N1

350

460

400

520

SPX350A2-4A4N1

2
2
2
2

380–500V, Open Chassis Drives
Frame
Size

hp (IH)

Current (IH)

hp (IL)

Current (IL)

Catalog Number

FR10

250

330

300

385

SPX250A0-4A2N1

300

385

—

460

SPX300A0-4A2N1

350

460

400

520

SPX350A0-4A2N1

400

520

500

590

SPX400A0-4A2N1

FR11

FR12

FR13

FR14

500

590

—

650

SPX500A0-4A2N1

—

650

600

730

SPX550A0-4A2N1

600

730

—

820

SPX600A0-4A2N1

—

820

700

920

SPX650A0-4A2N1

700

920

800

1030

SPX700A0-4A2N1

800

1030

900

1150

SPX800A0-4A2N1

900

1150

1000

1300

SPX900A0-4A2N1

1000

1300

1200

1450

SPXH10A0-4A2N1

1200

1600

1500

1770

SPXH12A0-4A2N1

1600

1940

1800

2150

SPXH16A0-4A2N1

2
2
2
2
2
2
2
2
2
2

Notes
Integrated fuses as standard. Limited option selection available; 115V transformer (KB), light kit (L1), HOA (K4),
speed potentiometer w/HOA (K2), disconnect switch (P2). See Freestanding Option selection on Page V6-T2-173.
1 FR10–FR14 includes 3% line reactor, but it is not integral to chassis.

Volume 6—Solid-State Motor Control CA08100007E—May 2014 www.eaton.com

2
V6-T2-163

2.7
2

575V Drives

2

SPX9000 Open Drives

Adjustable Frequency Drives
SPX9000 Drives

525–690V, NEMA Type 1/IP21 Drives
Frame
Size

2

FR6

hp (IH)

Current (IH)

hp (IL)

Current (IL)

Catalog Number

2

3.3

3

4.5

SPX002A1-5A4N1

2

3

4.5

—

5.5

SPX003A1-5A4N1

—

5.5

5

7.5

SPX004A1-5A4N1

2

5

7.5

7-1/2

10

SPX005A1-5A4N1

2

7-1/2

10

10

13.5

SPX007A1-5A4N1

10

13.5

15

18

SPX010A1-5A4N1

2

15

18

20

22

SPX015A1-5A4N1

20

22

25

27

SPX020A1-5A4N1

25

27

30

34

SPX025A1-5A4N1

30

34

40

41

SPX030A1-5A4N1

40

41

50

52

SPX040A1-5A4N1

50

52

60

62

SPX050A1-5A4N1

60

62

75

80

SPX060A1-5A4N1

75

80

100

100

SPX075A1-5A4N1

100

100

125

125

SPX100A1-5A4N1

2

125

125

150

144

SPX125A1-5A4N1

2

150

144

—

170

SPX150A1-5A4N1

—

170

200

208

SPX175A1-5A4N1

2

FR7

2

FR8

2
2

FR9

2

525–690V, NEMA Type 1/IP21 Freestanding Drives

2
2

Frame
Size

hp (IH)

Current (IH)

hp (IL)

Current (IL)

Catalog Number

FR10

200

208

250

261

SPX200A1-5A4N1

250

261

300

325

SPX250A1-5A4N1

300

325

400

385

SPX300A1-5A4N1

400

385

450

460

SPX400A1-5A4N1

450

460

500

502

SPX450A1-5A4N1

500

502

550

590

SPX500A1-5A4N1

2
2

FR11

2
2

Note
Integrated fuses as standard. Limited option selection available; 115V transformer (KB), light kit (L1), HOA (K4),
speed potentiometer w/HOA (K2), disconnect switch (P2). See Freestanding Option selection on Page V6-T2-173.

2
2
2
2
2
2
2
2
2
2
V6-T2-164

Volume 6—Solid-State Motor Control CA08100007E—May 2014 www.eaton.com

Adjustable Frequency Drives
SPX9000 Drives

SPX9000 Open Drives

2.7

525–690V, NEMA Type 12/IP54 Drives

2

Frame
Size

hp (IH)

Current (IH)

hp (IL)

Current (IL)

Catalog Number

FR6

2

3.3

3

4.5

SPX002A2-5A4N1

3

4.5

—

5.5

SPX003A2-5A4N1

—

5.5

5

7.5

SPX004A2-5A4N1

5

7.5

7-1/2

10

SPX005A2-5A4N1

7-1/2

10

10

13.5

SPX007A2-5A4N1

10

13.5

15

18

SPX010A2-5A4N1

15

18

20

22

SPX015A2-5A4N1

20

22

25

27

SPX020A2-5A4N1

25

27

30

34

SPX025A2-5A4N1

30

34

40

41

SPX030A2-5A4N1

40

41

50

52

SPX040A2-5A4N1

50

52

60

62

SPX050A2-5A4N1

60

62

75

80

SPX060A2-5A4N1

FR7

FR8

FR9

75

80

100

100

SPX075A2-5A4N1

100

100

125

125

SPX100A2-5A4N1

125

125

150

144

SPX125A2-5A4N1

150

144

—

170

SPX150A2-5A4N1

—

170

200

208

SPX175A2-5A4N1

2
2
2
2
2
2
2
2
2
2
2
2

525–690V, NEMA Type 12/IP54 Freestanding Drives
Frame
Size
FR10

hp (IH)

Current (IH)

hp (IL)

2

Current (IL)

Catalog Number

200

208

250

261

SPX200A2-5A4N1

250

261

300

325

SPX250A2-5A4N1

300

325

400

385

SPX300A2-5A4N1

2
2
2
2

525–690V, Open Chassis Drives
Frame
Size

hp (IH)

Current (IH)

hp (IL)

Current (IL)

Catalog Number

FR10

200

208

250

261

SPX200A0-5A2N1

250

261

300

325

SPX250A0-5A2N1

300

325

400

385

SPX300A0-5A2N1

400

385

450

460

SPX400A0-5A2N1

450

460

500

502

SPX450A0-5A2N1

500

502

—

590

SPX500A0-5A2N1

FR11

FR12

FR13

FR14

—

590

600

650

SPX550A0-5A2N1

600

650

700

750

SPX600A0-5A2N1

700

750

800

820

SPX700A0-5A2N1

800

820

900

920

SPX800A0-5A2N1

900

920

1000

1030

SPX900A0-5A2N1

1000

1030

1250

1180

SPXH10A0-5A2N1

1350

1300

1500

1500

SPXH13A0-5A2N1

1500

1500

2000

1900

SPXH15A0-5A2N1

2000

1900

2300

2250

SPXH20A0-5A2N1

2
2
2
2
2
2
2
2
2
2

Notes
Integrated fuses as standard. Limited option selection available; 115V transformer (KB), light kit (L1), HOA (K4),
speed potentiometer w/HOA (K2), disconnect switch (P2). See Freestanding Option selection on Page V6-T2-173.
1 FR10–FR14 includes 3% line reactor, but it is not integral to chassis.

Volume 6—Solid-State Motor Control CA08100007E—May 2014 www.eaton.com

2
2
V6-T2-165

2.7

Adjustable Frequency Drives
SPX9000 Drives

2

Accessories

2

Demo Drive and Power Supply

2
2
2
2
2
2
2

Demo Drive and Power Supply
Description

Catalog Number

9000X demo drive

9000XDEMO

NEMA Type 12/IP54 Conversion Kit
The NEMA Type 12/IP54 kit
option is used to convert a
NEMA Type 1/IP21 to a
NEMA Type 12/IP54 drive.
The NEMA Type 12/IP54

kit consists of a metal
drive shroud, fan kit for
some frames, adaptor plate
and plugs.

NEMA Type 12/IP54 Conversion Kit
Approximate Dimensions in Inches (mm)
Frame Size

Delivery Code

Length

Width

Height

Approximate
Weight Lb (kg)

Catalog Number

2

FR4

W

13 (330)

7 (178)

4 (102)

4 (1.8)

OPTN12FR4

2

FR5

16 (406)

8 (203)

7 (178)

5 (2.3)

OPTN12FR5

FR6

21 (533)

10 (254)

5 (127)

7 (3.2)

OPTN12FR6

2
2
2
2
2
2
2

Flange Kits
Flange Kit NEMA Type
12/IP54
The flange kit is utilized when
the power section is mounted
through the back panel of an
enclosure. Includes flange
mount brackets and NEMA
Type 12/IP54 fan
components. Metal shroud
not included.

Flange kits for NEMA Type
12/IP54 enclosure drive rating
are determined by rating of
drive.

Flange Kit NEMA Type 12/
IP54—Frames 4–9
Frame
Size

Delivery
Code

Catalog
Number

Flange Kit NEMA Type 12/
IP54— Frames 4, 5 and 6 1

FR4

FP

OPTTHR4

FR5

OPTTHR5

Frame
Size

FR6

OPTTHR6

FR7

OPTTHR7

FR8

OPTTHR8

FR9

OPTTHR9

FR4

2

Delivery
Code
W

Catalog
Number
OPTTHRFR4

FR5

OPTTHRFR5

FR6

OPTTHRFR6

2
2
2

Note
1 For installation of an SPX9000 NEMA Type 1/IP21 drive into a NEMA Type 12/IP54 oversized enclosure.

2
2
2
2
2
2
2
2
V6-T2-166

Volume 6—Solid-State Motor Control CA08100007E—May 2014 www.eaton.com

2.7

Adjustable Frequency Drives
SPX9000 Drives

Options

2

9000X Series Option Board Kits

2

The 9000X Series drives can accommodate a wide selection of expander and adapter option boards
to customize the drive for your application needs. The drive’s control unit is designed to accept a
total of five option boards.

2
2

The 9000X Series factory installed standard board configuration includes an A9 I/O board and an A2
relay output board, which are installed in slots A and B.
Option Boards

2

Option Board Kits

2

Allowed Slot
Locations 2

Field
Installed
Catalog
Number

Factory
Installed
Option
Designator

SVX Ready Programs
Local/
Basic Remote Standard

MSS

PID

Multi-P. PFC

6 DI, 1 DO, 2 AI, 1AO, 1 +10 Vdc ref,
2 ext +24 Vdc/EXT +24 Vdc

A

OPTA9

—

■

■

■

■

■

■

■

2

2 RO (NC-NO)

B

OPTA2

—

■

■

■

■

■

■

■

2

2 RO, therm

B

OPTA3

A3

—

■

■

■

■

■

■

2

Encoder low volt +5V/15V/24V

C

OPTA4

A4

—

■

■

■

■

■

■

Encoder high volt +15V/24V

C

OPTA5

A5

—

■

■

■

■

■

■

Option Kit Description 1
Standard I/O Cards
A

D E
B C

Extended I/O Cards

2

2
2

Double encoder—SPX only

C

OPTA7

A7

■

■

■

■

■

■

■

6 DI, 1 DO, 2 AI, 1 AO

A

OPTA8

A8

—

■

■

■

■

■

■

6 DI, 1 DO, 2 AI, 1AO, 1 +10 Vdc ref,
2 ext +24 Vdc/EXT +24 Vdc

A

OPTA1

—

■

■

■

■

■

■

■

2

3 DI (encoder 10–24V), out +15V/+24V,
2 DO (pulse+direction)—SPX only

C

OPTAE

AE

■

■

■

■

■

■

■

2

6 DI, 1 DO, 2 AI, 1AO, 1 +10 Vdc ref,
2 ext +24 Vdc/EXT +24 Vdc

A

OPTAFA1

—

■

■

■

■

■

■

■

2

6 DI, 1 ext +24 Vdc/EXT +24 Vdc

B, C, D, E

OPTB1

B1

—

—

—

—

—

■

■

1 RO (NC-NO), 1 RO (NO), 1 therm

B, C, D, E

OPTB2

B2

—

—

—

—

—

■

■

1 AI (mA isolated), 2 AO (mA isolated),
1 ext +24 Vdc/EXT +24 Vdc

B, C, D, E

OPTB4

B4

—

■

■

■

■

■

■

3 RO (NO)

B, C, D, E

OPTB5

B5

—

—

—

—

—

■

■

1 ext +24 Vdc/EXT +24 Vdc, 3 Pt100

B, C, D, E

OPTB8

B8

—

—

—

—

—

—

—

1 RO (NO), 5 DI 42–240 Vac input

B, C, D, E

OPTB9

B9

—

—

—

—

—

■

■

SPI, absolute encoder

C

OPTBB

BB

—

—

—

—

—

—

—

Modbus 3

D, E

OPTC2

C2

■

■

■

■

■

■

■

Johnson Controls N2 3

D, E

OPTC2

CA

—

—

—

—

—

—

—

Communication Cards

Modbus TCP

D, E

OPTCI

CI

■

■

■

■

■

■

■

BACnet

D, E

OPTCJ

C4

■

■

■

■

■

■

■

EtherNet/IP

D, E

OPTCQ

CQ

■

■

■

■

■

■

■

PROFIBUS DP

D, E

OPTC3

C3

■

■

■

■

■

■

■

LonWorks

D, E

OPTC4

C4

■

■

■

■

■

■

■

PROFIBUS DP (D9 connector)

D, E

OPTC5

C5

■

■

■

■

■

■

■

CANopen (slave)

D, E

OPTC6

C6

■

■

■

■

■

■

■

DeviceNet

D, E

OPTC7

C7

■

■

■

■

■

■

■

Modbus (D9 type connector)

D, E

OPTC8

C8

■

■

■

■

■

■

■

Adapter—SPX only

D, E

OPTD1

D1

■

■

■

■

■

■

■

Adapter—SPX only

D, E

OPTD2

D2

■

■

■

■

■

■

■

RS-232 with D9 connection

D, E

OPTD3

D3

■

■

■

■

■

■

■

Notes
1 AI = Analog Input; AO = Analog Output, DI = Digital Input, DO = Digital Output, RO = Relay Output
2 Option card must be installed in one of the slots listed for that card. Slot indicated in bold is the preferred location.
3 OPTC2 is a multi-protocol option card.

Volume 6—Solid-State Motor Control CA08100007E—May 2014 www.eaton.com

2
2
2
2
2
2
2
2
2
2
2
2
2
2
2

V6-T2-167

2.7
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2

Adjustable Frequency Drives
SPX9000 Drives

Modbus RTU Network
Communications
The Modbus Network Card
OPTC2 is used for connecting
the 9000X Drive as a slave on
a Modbus network. The
interface is connected by a
9-pin DSUB connector
(female) and the baud rate
ranges from 300 to 19200
baud. Other communication
parameters include an
address range from 1 to 247;
a parity of None, Odd or
Even; and the stop bit is 1.

DeviceNet Network
Communications
The DeviceNet Network Card
OPTC7 is used for connecting
the 9000X Drive on a
DeviceNet Network. It
includes a 5.08 mm pluggable
connector. Transfer method
is via CAN using a two-wire
twisted shielded cable with
two-wire bus power cable
and drain. The baud rates
used for communication
include 125K baud, 250K
baud and 500K baud.

PROFIBUS Network
Communications
The PROFIBUS Network Card
OPTC3 is used for connecting
the 9000X Drive as a slave
on a PROFIBUS-DP network.
The interface is connected
by a 9-pin DSUB connector
(female). The baud rates
range from 9.6K baud to 12M
baud, and the addresses
range from 1 to 127.

Johnson Controls Metasys N2
Network Communications
The OPTC2 fieldbus board
provides communication
between the 9000X Drive and
a Johnson Controls
Metasys™ N2 network. With
this connection, the drive can
be controlled, monitored and
programmed from the
Metasys system. The N2
fieldbus is available as a
factory installed option and as
a field installable kit.

LonWorks Network
Communications
The LonWorks Network Card
OPTC4 is used for connecting
the 9000X Drive on a
LonWorks network. This
interface uses Standard
Network Variable Types
(SNVT) as data types. The
channel connection is
achieved using a FTT-10A
Free Topology transceiver
via a single twisted transfer
cable. The communication
speed with LonWorks is
78 kBits/s.
CANopen (Slave)
Communications
The CANopen (Slave)
Network Card OPTC6 is used
for connecting the 9000X
Drive to a host system.
According to ISO11898
standard cables to be chosen
for CAN bus should have a
nominal impedance of 120
ohms, and specific line delay
of nominal 5 nS/m. 120 ohms
line termination resistors
required for installation.

Modbus/TCP Network
Communications
The Modbus/TCP Network
Card OPTCI is used for
connecting the 9000X Drive
to Ethernet networks utilizing
Modbus protocol. It includes
an RJ-45 pluggable connector.
This interface provides a
selection of standard and
custom register values to
communicate drive parameters.
The board supports 10 Mbps
and 100 Mbps communication
speeds. The IP address of the
board is configurable over
Ethernet using a supplied
software tool.

BACnet Network
Communications
The BACnet Network Card
OPTCJ is used for connecting
the 9000X Drive to BACnet
networks. It includes a
5.08 mm pluggable connector.
Data transfer is Master-Slave/
Token Passing (MS/TP)
RS-485. This interface uses
a collection of 30 Binary Value
Objects (BVOs) and 35 Analog
Value Objects (AVOs) to
communicate drive parameters.
The card supports 9.6, 19.2
and 38.4 Kbaud communication
speeds and supports network
addresses 1–127.
EtherNet/IP Network
Communications
The EtherNet/IP Network
Card OPTCK is used for
connecting the 9000X Drive
to Ethernet/Industrial Protocol
networks. It includes an
RJ-45 pluggable connector.
The interface uses CIP
objects to communicate drive
parameters (CIP is “Common
Industrial Protocol”, the same
protocol used by DeviceNet).
The board supports 10 Mbps
and 100 Mbps communication
speeds. The IP address of the
board is configurable by Static,
BOOTP and DHCP methods.

2
2
2
V6-T2-168

Volume 6—Solid-State Motor Control CA08100007E—May 2014 www.eaton.com

Adjustable Frequency Drives
SPX9000 Drives

2.7

Control Panel Options

2

Factory Options

Description

Factory Installed

Field Installed

Option Code

NEMA Type 1/IP21
Catalog Number

Local/Remote Keypad SVX9000 Control Panel—This option is standard on all drives and
A
consists of an RS-232 connection, backlit alphanumeric LCD display with nine indicators for the
RUN status and two indicators for the control source. The nine pushbuttons on the panel are used
for panel programming and monitoring of all SVX9000 parameters. The panel is detachable and
isolated from the input line potential. Include LOC/REM key to choose control location.

KEYPAD-LOC/REM

Keypad Remote Mounting Kit—This option is used to remote mount the SVX9000 keypad. The
footprint is compatible to the SV9000 remote mount kit. Includes 10 ft cable, keypad holder and
mounting hardware.

—

OPTRMT-KIT-9000X

Keypad Blank—9000X Series select keypad for use with special and custom applications.

—

KEYPAD-BLANK

2
2
2
2
2
2
2

Miscellaneous Options
Description

Catalog Number

9000XDrive—A PC-based tool for controlling and monitoring of the SVX9000. Features include: loading parameters that
can be saved to a file or printed, setting references, starting and stopping the motor, monitoring signals in graphical or text
form, and real-time display. To avoid damage to the drive or computer, SVDrivecable must be used.

9000XDRIVE

SVDrivecable—6 ft (1.8m) RS-232 cable (22 gauge) with a 7-pin connector on each end. Should be used in conjunction
with the 9000XDrive option to avoid damage to the SVX9000 or computer. The same cable can be used for downloading
specialized applications to the drive.

SVDRIVECABLE

External Dynamic Braking Resistors—Used with the dynamic braking chopper circuit to absorb motor regenerative
energy for stopping the load and to dissipate the energy flowing back into the drive. Resistors are separated into standard
duty and heavy-duty. Standard duty is defined as 20% duty or less with 100% braking torque, while heavy-duty is defined as
50% duty or less with 150% braking torque.

See Page V6-T2-170

2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2

Volume 6—Solid-State Motor Control CA08100007E—May 2014 www.eaton.com

V6-T2-169

2.7
2
2
2
2
2
2
2
2

Adjustable Frequency Drives
SPX9000 Drives

SPX9000 Drive Options
Brake Chopper Options
The brake chopper circuit
option is used for applications
that require dynamic braking.
Dynamic braking resistors are
not included with drive
purchase. Consult the factory
for additional dynamic braking
resistor selections that are
supplied separately. A list of
common resistors are listed
below and are complete
indoor assemblies, include a
pre-wired terminal block and
a thermal switch, and are not
UL Listed.

Duty Cycle
The duty cycle rating is based
on a 60-second period. For
example, the 20% duty cycle
resistor can carry 100%
current for 12 seconds out
of every 60 seconds, while
the 50% duty cycle resistor
can carry 150% current for
30 seconds out of every
60 seconds.

Torque
If the braking torque required
is less than 15%, dynamic
braking is not required
because the regenerated
energy will be dissipated in
the drive and motor losses.

2
2

Dynamic Brake Resistor—Catalog Number Selection

DBR – R100 – W0800

2
2

Dynamic Brake Resistor

Resistance
1D0 = 1.0 Ohms
100 = 100 Ohms

2

Rated Watts
0800 = 800 Watts
8000 = 8000 Watts
080K = 80,000 Watts

2

230V Brake Resistors

2

Drive hp
(CT/IH)

Minimum
Ohms

20% Duty Cycle, 100% Torque

50% Duty Cycle, 150% Torque

Catalog Number

Dimensions (Inches)

Catalog Number

Dimensions (Inches)

2

0.75

30.0

DBR-R100-W0400

12W x 5D x 5H

DBR-R100-W0800

12W x 7D x 5H

2

1

30.0

DBR-R100-W0400

12W x 5D x 5H

DBR-R100-W0800

12W x 7D x 5H

1.5

30.0

DBR-R100-W0400

12W x 5D x 5H

DBR-R036-W1200

12W x 10D x 5H

2

2

30.0

DBR-R100-W0400

12W x 5D x 5H

DBR-R036-W1200

12W x 10D x 5H

3

30.0

DBR-R036-W0800

12W x 7D x 5H

DBR-R036-W2000

12W x 16D x 5H

2

4

30.0

DBR-R036-W0800

12W x 7D x 5H

DBR-R030-W2400

19W x 10D x 5H

5

30.0

DBR-R036-W0800

12W x 7D x 5H

DBR-R030-W2800

19W x 13D x 5H

2

7.5

20.0

DBR-R020-W1200

12W x 10D x 5H

DBR-R020-W4800

26.5W x 13D x 5H

2

10

10.0

DBR-R015-W1600

12W x 13D x 5H

DBR-R112-W6000

26.5W x 13D x 5H

15

10.0

DBR-R012-W2400

19W x 10D x 5H

DBR-R010-W9000

28W x 10D x 10H

2

20

3.3

DBR-R9D3-W3200

19W x 10D x 5H

DBR-R3D4-W012K

28W x 10D x 10H

25

3.3

DBR-R5D5-W4000

26.5W x 10D x 5H

DBR-R5D1-W015K

28W x 16D x 10H

2

30

3.3

DBR-R4D8-W4800

26.5W x 10D x 5H

DBR-R4D1-W020K

28W x 16D x 10H

2

40

1.4

DBR-R004-W6000

26.5W x 13D x 5H

DBR-R3D4-W025K

30W x 18D x 16H

50

1.4

DBR-R3D1-W7500

26.5W x 16D x 5H

DBR-R2D1-W030K

30W x 18D x 24H

2

60

1.4

DBR-R2D8-W9000

26.5W x 16D x 5H

DBR-R002-W036K

30W x 18D x 24H

75

1.4

DBR-R2D6-W012K

28W x 10D x 10H

DBR-R1D5-W045K

30W x 18D x 32H

2

100

1.4

DBR-R002-W015K

28W x 16D x 10H

DBR-R1D4-W060K

30W x 18D x 40H

2
2
2
2
V6-T2-170

Volume 6—Solid-State Motor Control CA08100007E—May 2014 www.eaton.com

Adjustable Frequency Drives
SPX9000 Drives

2.7

480V Brake Resistors
Drive hp
(CT/IH)

Minimum
Ohms

20% Duty Cycle, 100% Torque

50% Duty Cycle, 150% Torque

Catalog Number

Dimensions (Inches)

Catalog Number

Dimensions (Inches)

1

63.0

DBR-R100-W0400

12W x 5D x 5H

DBR-R100-W0800

12W x 7D x 5H

1.5

63.0

DBR-R100-W0400

12W x 5D x 5H

DBR-R100-W1200

12W x 10D x 5H

2

63.0

DBR-R100-W0400

12W x 5D x 5H

DBR-R100-W1200

12W x 10D x 5H

3

63.0

DBR-R100-W0800

12W x 7D x 5H

DBR-R100-W2000

12W x 16D x 5H

5

63.0

DBR-R100-W0800

12W x 7D x 5H

DBR-R100-W2800

19W x 13D x 5H

6

63.0

DBR-R100-W1200

12W x 10D x 5H

DBR-R070-W4000

19W x 16D x 5H

7.5

63.0

DBR-R100-W1200

12W x 10D x 5H

DBR-R063-W4800

26.5W x 13D x 5H

10

63.0

DBR-R063-W1600

12W x 13D x 5H

DBR-R063-W6000

26.5W x 16D x 5H

15

42.0

DBR-R042-W2400

19W x 10D x 5H

DBR-R042-W9000

28W x 10D x 10H

20

21.0

DBR-R030-W3200

19W x 13D x 5H

DBR-R023-W012K

28W x 13D x 10H

25

21.0

DBR-R030-W4000

19W x 16D x 5H

DBR-R021-W015K

28W x 13D x 10H

30

14.0

DBR-R020-W4800

26.5W x 13D x 5H

DBR-R014-W020K

30W x 18D x 24H

40

6.5

DBR-R112-W6000

26.5W x 13D x 5H

DBR-R007-W025K

30W x 18D x 16H

50

6.5

DBR-R013-W7500

26.5W x 16D x 5H

DBR-R8D5-W030K

30W x 18D x 24H

60

6.5

DBR-R010-W9000

28W x 10D x 10H

DBR-R7D3-W036K

30W x 18D x 24H

75

3.3

DBR-R009-W012K

28W x 13D x 10H

DBR-R3D3-W045K

30W x 18D x 32H

100

3.3

DBR-R5D1-W015K

28W x 16D x 10H

DBR-R004-W060K

30W x 18D x 40H

125

3.3

DBR-R4D1-W020K

28W x 16D x 10H

DBR-R004-W070K

30W x 18D x 48H

150

3.3

DBR-R3D4-W025K

30W x 18D x 16H

DBR-R3D5-W085K

30W x 18D x 56H

200

3.3

DBR-R3D3-W030K

30W x 18D x 24H

DBR-R3D3-W110K

30W x 18D x 72H

250

1.4

DBR-R2D5-W036K

30W x 18D x 24H

1

—

300

1.4

DBR-R1D5-W045K

30W x 18D x 32H

1

—

350

1.4

DBR-R1D4-W060K

30W x 18D x 40H

1

—

400

0.9

DBR-R1D4-W060K

30W x 18D x 40H

1

—

500

0.9

DBR-R0D9-W080K

30W x 18D x 48H

1

—

550

0.9

DBR-R001-W085K

30W x 18D x 56H

1

—

2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2

Note
1 Consult factory.

2
2
2
2
2
2
2
2
2
2
2
2
2
Volume 6—Solid-State Motor Control CA08100007E—May 2014 www.eaton.com

V6-T2-171

2.7
2

Adjustable Frequency Drives
SPX9000 Drives

575V Brake Resistors
Drive hp
(CT/IH)

Minimum
Ohms

20% Duty Cycle, 100% Torque
Catalog Number
Dimensions (Inches)

50% Duty Cycle, 150% Torque
Catalog Number
Dimensions (Inches)

2

100.0

DBR-R100-W0400

12W x 5D x 5H

DBR-R100-W1200

12W x 10D x 5H

2

3

100.0

DBR-R100-W0800

12W x 7D x 5H

DBR-R100-W2000

12W x 16D x 5H

2

4

100.0

DBR-R100-W0800

12W x 7D x 5H

DBR-R100-W2400

19W x 10D x 5H

5

100.0

DBR-R100-W0800

12W x 7D x 5H

DBR-R100-W2800

19W x 13D x 5H

2

7.5

100.0

DBR-R100-W1200

12W x 10D x 5H

DBR-R100-W4800

26.5W x 13D x 5H

10

30.0

DBR-R063-W1600

12W x 13D x 5H

DBR-R063-W6000

26.5W x 16D x 5H

2

15

30.0

DBR-R042-W2400

19W x 10D x 5H

DBR-R042-W9000

28W x 10D x 10H

20

30.0

DBR-R030-W3200

19W x 13D x 5H

DBR-R030-W012K

28W x 13D x 10H

2

25

30.0

DBR-R030-W4000

19W x 16D x 5H

DBR-R030-W015K

28W x 16D x 10H

30

18.0

DBR-R020-W4800

26.5W x 13D x 5H

DBR-R020-W020K

30W x 18D x 16H

2

40

18.0

DBR-R030-W6000

26.5W x 16D x 5H

DBR-R184-W025K

30W x 18D x 16H

2

50

9.0

DBR-R013-W7500

26.5W x 16D x 5H

DBR-R012-W030K

30W x 18D x 24H

60

9.0

DBR-R010-W9000

28W x 10D x 10H

DBR-R010-W036K

30W x 18D x 24H

2

75

9.0

DBR-R009-W012K

28W x 13D x 10H

DBR-R009-W045K

30W x 18D x 24H

100

7.0

DBR-R013-W015K

28W x 16D x 10H

DBR-R8D4-W060K

30W x 18D x 40H

2

125

7.0

DBR-R8D2-W020K

30W x 18D x 10H

DBR-R007-W070K

30W x 18D x 40H

150

7.0

DBR-R007-W025K

30W x 18D x 16H

DBR-R006-W085K

30W x 18D x 56H

2

175

7.0

DBR-R007-W030K

30W x 18D x 24H

DBR-R007-W100K

30W x 18D x 72H

200

2.5

DBR-R3D3-W030K

30W x 18D x 24H

DBR-R2D6-W110K

30W x 18D x 64H

250

2.5

DBR-R2D5-W036K

30W x 18D x 24H

DBR-R003-W140K

30W x 18D x 72H

300

2.5

DBR-R3D3-W045K

30W x 18D x 32H

1

—

400

1.7

DBR-R002-W060K

30W x 18D x 48H

1

—

2

450

1.7

DBR-R1D8-W070K

30W x 18D x 48H

1

—

500

1.7

DBR-R002-W080K

30W x 18D x 56H

1

—

2

Note
1 Consult factory.

2

2
2

2
2
2
2
2
2
2
2
2
2
2
2
2
2
V6-T2-172

Volume 6—Solid-State Motor Control CA08100007E—May 2014 www.eaton.com

Adjustable Frequency Drives
SPX9000 Drives

2.7

Control/Communication Options

2

Available Control/Communications Options

2

Option

Description

Option Type

K2

Door-Mounted Speed Potentiometer with HOA Selector Switch—Provides the SPX9000 with the ability to start/stop and adjust the speed reference from
door-mounted control devices or remotely from customer supplied inputs. In HAND position, the drive will start and the speed is controlled by the door-mounted
speed potentiometer. The drive will be disabled in the OFF position. When AUTO is selected, the drive run and speed control commands are via user-supplied dry
contact and 4–20 mA signal.

Control

K4

HAND/OFF/AUTO Switch for Non-Bypass Configurations—Provides a three-position selector switch that allows the user to select either a HAND or AUTO
mode of operation. HAND mode is defaulted to keypad operation, and AUTO mode is defaulted to control from an external terminal source. These modes of operation
can be configured via programming to allow for alternate combinations of start and speed sources. Start and speed sources include keypad, I/O and fieldbus.

Control

KB

115V Control Transformer, 550 VA—Provides a fused control power transformer with additional 550 VA at 115V for customer use.

Control

L1

Power On and Fault Pilot Lights—Provide a white power on light that indicates power to the enclosed cabinet and a red fault light that indicates a drive fault
has occurred.

Light

2

P2

Disconnect Switch—Disconnect switch option is applicable only with NEMA Type 1/IP21 and NEMA Type 12/IP54 Freestanding drives. Allows a convenient
means of disconnecting the SPX9000 from the line, and the operating mechanism can be padlocked in the OFF position. This is factory-mounted in the enclosure.

Input

2

2
2
2

2
2

SPX Freestanding Options

2

480V and 690V Control Options, 200–550 hp 1
Description

Catalog Number
Suffix

Door-mounted speed potentiometer with HOA selector switch

K2

HAND/OFF/AUTO switch (22 mm)

K4

115 volt control transformer 550 VA

KB

2
2
2
2

480V and 690V Light Options, 200–550 hp 1
Description

Catalog Number
Suffix

Power on/fault pilot lights

L1

2
2
2

Input Options, 200–550 hp 1
Description

Catalog Number
Suffix

2

Disconnect switch

P2 2

2

Notes
1 Consult factory for adder information.
2 Applicable with FR10 and FR11 freestanding designs only.

2
2
2
2
2
2
2
2
2
2
2
Volume 6—Solid-State Motor Control CA08100007E—May 2014 www.eaton.com

V6-T2-173

2.7

Adjustable Frequency Drives
SPX9000 Drives

2

Replacement Parts

2

FR4 Spare Parts

2

Category

Description

2

Control fan

NEMA Type 12 control fan 1

1

PP01086

PP01086

—

Control module 2

SPX control module

1

CPBS0000000000

CPBS0000000000

—

2
2

Converter

Quantity/
Drive

230V

480V

575V

Catalog Number

Catalog Number

Catalog Number

Standard slot A I/O card

1

OPTA9

OPTA9

—

Standard slot B I/O card

1

OPTA2

OPTA2

—

Power board 3

1

VB00308-0004-2

VB00208-0003-5

—
—

1

VB00308-0007-2

VB00208-0004-5

2

1

VB00308-0008-2

VB00208-0005-5

—

2

1

—

VB00208-0007-5

—

1

—

VB00208-0009-5

—

1

—

VB00410-0012-5-ARV

—

1

KEYPAD-LOC/REM

KEYPAD-LOC/REM

—

2
2
2

Keypad 2

SVX/SPX keypad

Main fan 2

DC fan (main)

1

PP01060

PP01060

—

Other

Mounting kit, fixing kit

1

FR00040

FR00040

—

Mounting kit, fixing kit, N12

1

Control cover, plastic, N1

2

1

FR00079

FR00079

—

1

FR00006

FR00006

—

Quantity/
Drive

230V

480V

575V

Catalog Number

Catalog Number

Catalog Number

2

FR5 Spare Parts

2

Category

Description

Control fan

NEMA Type 12 control fan 1

1

PP01088

PP01088

—

Control module 2

SPX control module

1

CPBS0000000000

CPBS0000000000

—

2
2
2

Converter

Standard slot A I/O card

1

OPTA9

OPTA9

—

Standard slot B I/O card

1

OPTA2

OPTA2

—

Power board 3

1

VB00313-0017-2

VB00213-0016-5

—

1

VB00313-0025-2

VB00213-0022-5

—

1

VB00313-0031-2

VB00213-0031-5

—

1

KEYPAD-LOC/REM

KEYPAD-LOC/REM

—
—

2
2
2

Keypad 2

SVX/SPX keypad

Main fan 2

DC fan (main)

1

PP01061

PP01061

Other

Mounting kit, fixing kit

1

FR00050

FR00050

—

Mounting kit, fixing kit, N12 1

1

FR00081

FR00081

—

Control cover, plastic, N1

1

FR05011

FR05011

—

2
2
2

Notes
1 Only for NEMA Type 12/IP54 Type drives.
2 Factory recommended spare parts.
3 Select one part number based on the amperage rating of the drive. Please contact EatonCare at 877-ETN-CARE for assistance.

2
2
2
2
2
2
2
V6-T2-174

Volume 6—Solid-State Motor Control CA08100007E—May 2014 www.eaton.com

Adjustable Frequency Drives
SPX9000 Drives

2.7

FR6 Spare Parts
230V

480V

575V

Category

Description

Quantity/
Drive

Catalog Number

Catalog Number

Catalog Number

Control fan

NEMA Type 12 control fan 1

1

PP01049

PP01049

—

Control module 2

SPX control module

1

CPBS0000000000

CPBS0000000000

CPBS0000000000

Standard slot A I/O card

1

OPTA9

OPTA9

OPTA9

Standard slot B I/O card

1

OPTA2

OPTA2

OPTA2

1

VB00316-0048-2

VB00416-0038-5

VB00404-0004-6

1

VB00316-0061-2

VB00416-0045-5

VB00404-0005-6

1

—

VB00416-0061-5

VB00404-0007-6

1

—

—

VB00404-0010-6

1

—

—

VB00404-0013-6

1

—

—

VB00404-0018-6

1

—

—

VB00404-0022-6

1

—

—

VB00404-0027-6

1

—

—

VB00404-0034-6

Converter

Power board

3

DC section

Bus capacitor

2

—

—

S00930

Keypad 2

SVX/SPX keypad

1

KEYPAD-LOC/REM

KEYPAD-LOC/REM

KEYPAD-LOC/REM

Main fan 2

DC fan (main)

1

PP01062

PP01062

—

Other

Mounting kit, fixing kit

1

FR00060

FR00060

FR00060

Mounting kit, fixing kit, N12 1

1

FR00082

FR00082

FR00082

Control cover, plastic, N1

1

FR06011

FR06011

FR06011

2
2
2
2
2
2
2
2
2
2
2
2
2
2

FR7 Spare Parts
Category

Description

Control fan
Control module

Converter

DC section
Keypad

2

Main fan 2
Other

2

Quantity/
Drive

230V

480V

575V

Catalog Number

Catalog Number

Catalog Number

NEMA Type 12 control fan 1

1

PP01049

PP01049

PP01049

SPX control module

1

CPBS0000000000

CPBS0000000000

CPBS0000000000

Standard slot A I/O card

1

OPTA9

OPTA9

OPTA9

Standard slot B I/O card

1

OPTA2

OPTA2

OPTA2

Power board 3

1

VB00319-0075-2

VB00619-0072-5

VB00419-0041-6

1

VB00319-0088-2

VB00619-0087-5

VB00419-0052-6

1

VB00319-0114-2

VB00619-0105-5

—

Bus capacitor

2

—

—

PP01041

SVX/SPX keypad

1

KEYPAD-LOC/REM

KEYPAD-LOC/REM

KEYPAD-LOC/REM

DC fan (main)

1

PP01063

PP01063

PP01063

Mounting kit, fixing kit

1

FR07071

FR07071

FR07071

Mounting kit, fixing kit, N12 1

1

FR07072

FR07072

FR07072

Control cover, plastic, N1

1

FR07011

FR07011

FR07011

2
2
2
2
2
2
2
2
2

Notes
1 Only for NEMA Type 12/IP54 Type drives.
2 Factory recommended spare parts.
3 Select one part number based on the amperage rating of the drive. Please contact EatonCare at 877-ETN-CARE for assistance.

2
2
2
2
2
2
2

Volume 6—Solid-State Motor Control CA08100007E—May 2014 www.eaton.com

V6-T2-175

2.7

Adjustable Frequency Drives
SPX9000 Drives

2

FR8 Spare Parts

2

Category

Description

Control fan

NEMA Type 12 control fan 1

1

CP01180

CP01180

CP01180

Control module 2

SPX control module

1

CPBS0000000000

CPBS0000000000

CPBS0000000000

Standard slot A I/O card

1

OPTA9

OPTA9

OPTA9

Standard slot B I/O card

1

OPTA2

OPTA2

OPTA2

Power board 3

1

VB00722-0140-2-ANV

VB00636-0140-4-ANV

VB00422-0062-5-ANV

1

VB00722-0170-2-ANV

VB00636-0168-4-ANV

VB00422-0080-5-ANV

1

VB00722-0205-2-ANV

VB00636-0205-4-ANV

VB00422-0100-5-ANV

2

PP01175

PP01175

PP01127

2
2
2

Converter

2
2

IGBT

Quantity/
Drive

230V

480V

575V

Catalog Number

Catalog Number

Catalog Number

DC section

Bus capacitor

4

S00335

S00335

PP01041

Inverter

Diode

3

CP01268

CP01268

CP01373

Rectifier board

1

VB00227

VB00227

VB00427

SVX/SPX keypad

1

KEYPAD-LOC/REM

KEYPAD-LOC/REM

KEYPAD-LOC/REM

Fan AC

1

PP01123

PP01123

PP01123

2

Fan fuse

2

PP20202

PP20202

PP20202

2

Starting cap

1

S00734

S00734

S00734

Fan driver board AC

1

VB00599

VB00799

VB00799

Isolation transformer (fan)

1

S0000113

S0000113

S0000113

2
2

2
2

Keypad

2

Main AC fan

Main DC fan 2

Other

2
2
2
2

DC fan

1

PP00071

PP00071

PP00071

DC power supply

1

S01016

S01016

S01016

Front cover, N12 1

1

FR08079

FR08079

FR08079

Conduit plate, N12

1

FR08082

FR08082

FR08082

Front cover, N1

1

FR08106

FR08106

FR08106

Notes
1 Only for NEMA Type 12/IP54 Type drives.
2 Factory recommended spare parts.
3 Select one part number based on the amperage rating of the drive. Please contact EatonCare at 877-ETN-CARE for assistance.

2
2
2
2
2
2
2
2
2
2
2
2
2
V6-T2-176

Volume 6—Solid-State Motor Control CA08100007E—May 2014 www.eaton.com

Adjustable Frequency Drives
SPX9000 Drives

2.7

FR9 Spare Parts
230V

480V

575V

Catalog Number

Catalog Number

Catalog Number

PP09041

PP09041

PP09041

Category

Description

Quantity/
Drive

Control fan

50 mm fan

1

80 mm fan

1

PP01068

PP01068

PP01068

Control module 1

SPX control module

1

CPBS0000000000

CPBS0000000000

CPBS0000000000

Standard slot A I/O card

1

OPTA9

OPTA9

OPTA9

Standard slot B I/O card

1

OPTA2

OPTA2

OPTA2

Power module 2

1

FR09-0261-2-ANV

FR09-0261-4-ANV

FR09-0125-5-ANV

1

FR09-0300-2-ANV

FR09-0300-4-ANV

FR09-0144-5-ANV

1

—

—

FR09-0170-5-ANV

Driver board

1

S00583

S00583

S00583

Shunt board 2

6

—

VB00535

VB00537

6

—

VB00536

VB00542

6

—

—

VB00543

Balancing resistor

3

PP00052

PP00052

PP00052

Bus capacitor

8

S00335

S00335

PP01041

DC busbars DC–

1

FR09043

FR09043

FR09043

DC busbars DC+

1

FR09044

FR09044

FR09044

DC busbars connection

1

FR09045

FR09045

FR09045

DC busbars +/– insulator

1

FR09046

FR09046

FR09046

Converter

DC section

DC busbars –/con insulator

1

FR09047

FR09047

FR09047

Rectifier module

1

FR09826

FR09822

FR09823

Diode

3

CP01268

CP01268

CP01268

Rectifier board

1

—

VB00459

VB00460

Keypad 1

SVX/SPX keypad

1

KEYPAD-LOC/REM

KEYPAD-LOC/REM

KEYPAD-LOC/REM

Main AC fan

Fan AC

1

PP01080

PP01080

PP01080

Fan fuse

2

PP20202

PP20202

PP20202

Inverter

Main DC fan

Other

1

Starting cap

1

S00465

S00465

S00465

Fan driver board AC

1

VB00899

VB00399

VB00299

Isolation transformer (fan)

1

PP09056

PP09055

PP09055

DC fan

1

PP00072

PP00072

PP00072

DC power supply

1

S01017

S01017

S01017

Front cover power

1

FR09012

FR09012

FR09012

Front cover connection

1

FR09013

FR09013

FR09013

Front power conduit

1

FR09014

FR09014

FR09014

2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2

Notes
1 Factory recommended spare parts.
2 Select one part number based on the amperage rating of the drive. Please contact EatonCare at 877-ETN-CARE for assistance.

2
2
2
2
2
2
2
2
2

Volume 6—Solid-State Motor Control CA08100007E—May 2014 www.eaton.com

V6-T2-177

2.7

Adjustable Frequency Drives
SPX9000 Drives

2

FR10 Spare Parts

2

Category
Control

575V
Catalog Number
S00451

1

—

S00451

—

S00457

S00457

Control fan

ASIC fan

1

—

PP01096

PP01096

Control module 1

SPX control module

1

—

CPBS0000000000

CPBS0000000000

Standard slot A I/O card

1

—

OPTA9

OPTA9

Standard slot B I/O card

1

—

OPTA2

OPTA2

Power module 2

1

—

FR10-0385-4-ANV

FR10-0261-5-ANV

1

—

FR10-0460-4-ANV

FR10-0325-5-ANV

1

—

FR10-0520-4-ANV

FR10-0385-5-ANV

1

—

—

FR10-0416-5-ANV

1

—

S00450

S00450

Driver adapter board

1

—

VB00330

VB00330

Shunt board 2

6

—

VB00497

VB00510

6

—

VB00498

VB00511

6

—

VB00537

VB00545

Top cover

1

—

FR10340

FR10340

Side cover

2

—

FR10341

FR10341

Balancing resistor

2

—

PP13027

PP13028

DC busbars kit (right)

1

—

S0000005

S0000005

Converter

2

Driver board

2
2
2

480V
Catalog Number

1

2

2

230V
Catalog Number

Fiber board

2
2

Quantity/
Drive

ASIC board

2
2

Description

Covers

DC section

2

Bus capacitor

12

—

S00335

S00336

Rectifier module

1

—

FR10823

FR10823

2

Charging resistor

1

—

PP00066

PP00066

Diode

3

—

PP01177

PP01177

2

Rectifier board

1

—

S00591

S00592

Keypad 1

SVX/SPX keypad

1

—

KEYPAD-LOC/REM

KEYPAD-LOC/REM

Main AC fan

Fan assembly (left)

1

—

FR10846

FR10846

Fan assembly (right)

1

—

FR10847

FR10847

Fan AC

2

—

PP01080

PP01080

2

Fan fuse

4

—

PP20202

PP20202

Starting cap

2

—

S00528

S00528

2

Fan driver board AC

2

—

VB00299

VB00299

Isolation transformer (left)

1

—

FR10844

FR10844

2

2

Inverter

2

2
2
2
2

Main DC fan 1

Isolation transformer (right)

1

—

FR10845

FR10845

DC fan

2

—

PP00072

PP00072

DC power supply

2

—

S01017

S01017

Notes
1 Factory recommended spare parts.
2 Select one part number based on the amperage rating of the drive. Please contact EatonCare at 877-ETN-CARE for assistance.

2
2
2
2
2
2
V6-T2-178

Volume 6—Solid-State Motor Control CA08100007E—May 2014 www.eaton.com

Adjustable Frequency Drives
SPX9000 Drives

2.7

FR11 Spare Parts
230V

480V

575V

Category

Description

Quantity/
Drive

Catalog Number

Catalog Number

Catalog Number

Control

Fiber board

1

—

S00451

S00451

ASIC board

1

—

S00457

S00457

Control fan

ASIC fan

1

—

PP01096

PP01096

Control module 1

SPX control module

1

—

CPBS0000000000

CPBS0000000000

Converter

Standard slot A I/O card

1

—

OPTA9

OPTA9

Standard slot B I/O card

1

—

OPTA2

OPTA2

1

—

FR11-0590-4-ANV

FR11-0460-5-ANV

1

—

FR11-0650-4-ANV

FR11-0502-5-ANV

1

—

FR11-0730-4-ANV

FR11-0590-5-ANV

1

—

S00452

S00452

Driver adapter board

1

—

VB00330

VB00330

Shunt board 2

9

—

VB00513

VB00512

9

—

VB00514

VB00546

9

—

VB00538

VB00547

1

—

FR11345

FR11345

Power module

2

Driver board

Covers

Top cover

DC section

Inverter

Keypad 1
Main AC fan

Main DC fan

1

Balancing resistor

3

—

PP13027

PP13027

DC busbars kit (right)

3

—

S0000005

S0000005

Bus capacitor

18

—

S00335

S00335

Rectifier module

1

—

FR10823

FR10823

Diode

3

—

PP01177

PP01177

Rectifier board

1

—

S00591

S00591

SVX/SPX keypad

1

—

KEYPAD-LOC/REM

KEYPAD-LOC/REM

Fan assembly (right)

3

—

FR10847

FR10847

Fan AC

3

—

PP01080

PP01080

Fan fuse

4

—

PP20202

PP20202

Starting cap

3

—

S00530

S00530

Fan driver board AC

3

—

VB00299

VB00299

Isolation transformer (right)

3

—

FR10845

FR10845

DC fan

2

—

PP00072

PP00072

DC power supply

2

—

S01017

S01017

2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2

Notes
1 Factory recommended spare parts.
2 Select one part number based on the amperage rating of the drive. Please contact EatonCare at 877-ETN-CARE for assistance.

2
2
2
2
2
2
2
2
2
2

Volume 6—Solid-State Motor Control CA08100007E—May 2014 www.eaton.com

V6-T2-179

2.7

Adjustable Frequency Drives
SPX9000 Drives

2

FR12 Spare Parts

2

Category
Control

2
2
2
2
2

Description

Quantity/
Drive

230V

480V

575V

Catalog Number

Catalog Number

Catalog Number

Fiber board

2

—

S00451

S00451

ASIC board

2

—

S00457

S00457

Star coupler

1

—

S00593

S00593

Control fan

ASIC fan

2

—

PP01096

PP01096

Control module 1

SPX control module

1

—

CPBS0000000000

CPBS0000000000

Converter

Standard slot A I/O card

1

—

OPTA9

OPTA9

Standard slot B I/O card

1

—

OPTA2

OPTA2

Power module 2

1

—

FR12-0820-4-ANV

FR12-0650-5-ANV

1

—

FR12-0920-4-ANV

FR12-0750-5-ANV

1

—

FR12-1030-4-ANV

FR12-0820-5-ANV

2

Driver board

2

—

S00450

S00450

2

Driver adapter board

2

—

VB00330

VB00330

Shunt board

12

—

VB00498

VB00511

Top cover

2

—

FR10340

FR10340

Side cover

4

—

FR10341

FR10341

Balancing resistor

4

—

PP13027

PP13027

DC busbars kit (right)

2

—

S0000005

S0000005

2

Covers

2

DC section

2
2
2
2

Bus capacitor

24

—

S00335

S00336

Rectifier module

2

—

FR10823

FR10823

Diode

3

—

PP01177

PP01177

Rectifier board

2

—

S00591

S00591

Keypad 1

SVX/SPX keypad

1

—

KEYPAD-LOC/REM

KEYPAD-LOC/REM

Main AC fan

Fan assembly (left)

2

—

FR10846

FR10846

Inverter

2
2
2
2
2
2
2

Main DC fan 1

Fan assembly (right)

2

—

FR10847

FR10847

Fan AC

4

—

PP01080

PP01080

Fan fuse

8

—

PP20202

PP20202

Starting cap

4

—

S00528

S00528

Fan driver board AC

4

—

VB00299

VB00299

Isolation transformer (left)

2

—

FR10844

FR10844

Isolation transformer (right)

2

—

FR10845

FR10845

DC fan

4

—

PP00072

PP00072

DC power supply

4

—

S01017

S01017

Notes
1 Factory recommended spare parts.
2 Select one part number based on the amperage rating of the drive. Please contact EatonCare at 877-ETN-CARE for assistance.

2
2
2
2
2
2
2
2
V6-T2-180

Volume 6—Solid-State Motor Control CA08100007E—May 2014 www.eaton.com

Adjustable Frequency Drives
SPX9000 Drives

2.7

FR13 Spare Parts
230V

480V

575V

Category

Description

Quantity/
Drive

Catalog Number

Catalog Number

Catalog Number

Control

ASIC board

1

—

S00457

S00457

ASIC assembly

1

—

60S01030

60S01030

Control fan

ASIC fan

1

—

PP01096

PP01096

Control module 1

SPX control module

1

—

CPBS0000000000

CPBS0000000000

Converter

Standard slot A I/O card

1

—

OPTA9

OPTA9

Standard slot B I/O card

1

—

OPTA2

OPTA2

3

—

FI13-1150-4-ANV

FR13-1030-5-ANV

3

—

FI13-1300-4-ANV

FR13-1180-5-ANV

3

—

FI13-1450-4-ANV

FR13-920-5-ANV

3

—

S00454

S00454

Driver adapter board

2

—

VB00330

VB00330

Shunt board 2

18

—

VB00505

VB00516

18

—

VB00514

VB00517

Power module

2

Driver board

Covers

DC section

Inverter

18

—

VB00541

VB00547

Top cover

3

—

FI10001

FI10001

Side cover

3

—

FI10003

FI10003

Balancing resistor

6

—

PP13034

PP13034

Bus capacitor

36

—

S00335

S00336

DC busbars kit

3

—

FI13329

FI13329

Rectifier module

2

—

FR10823

FR10823

Diode

3

—

PP01177

PP01177

Rectifier board

2

—

S00591

S00591

Keypad 1

SVX/SPX keypad

1

—

KEYPAD-LOC/REM

KEYPAD-LOC/REM

Main AC fan

Fan assembly (left)

3

—

FI13301

FI13301

Fan AC

3

—

PP01080

PP01080

Main DC fan 1

Fan fuse

6

—

PP20202

PP20202

Starting cap

3

—

S00520

S00520

Fan driver board AC

3

—

VB00299

VB00299

Isolation transformer

3

—

PP10057

PP10057

DC fan

4

—

PP00072

PP00072

DC power supply

4

—

S01017

S01017

2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2

Notes
1 Factory recommended spare parts.
2 Select one part number based on the amperage rating of the drive. Please contact EatonCare at 877-ETN-CARE for assistance.

2
2
2
2
2
2
2
2
2
2

Volume 6—Solid-State Motor Control CA08100007E—May 2014 www.eaton.com

V6-T2-181

2.7

Adjustable Frequency Drives
SPX9000 Drives

2

FR14 Spare Parts

2

Category

Description

Control

2
2
2

230V

480V

575V

Catalog Number

Catalog Number

Catalog Number

ASIC board

2

—

S00457

S00457

Star coupler

1

—

S00593

S00593

ASIC assembly

2

—

60S01030

60S01030
FR10860

Star coupler kit

1

—

FR10860

Control fan

ASIC fan

2

—

PP01096

PP01096

Control module 1

SPX control module

1

—

CPBS0000000000

CPBS0000000000

2
2

Quantity/
Drive

Converter

Standard slot A I/O card

1

—

OPTA9

OPTA9

Standard slot B I/O card

1

—

OPTA2

OPTA2

Power module 2

1

—

FR14-1770-4-ANV

FR14-1500-5-ANV

1

—

FR14-2150-4-ANV

FR14-1900-5-ANV

1

—

FR14-2700-4-ANV

FR14-2250-5-ANV
S00454

2
2
2
2
2

Covers

DC section

2
2

6

—

S00454

2

—

VB00330

VB00330

Shunt board 2

36

—

VB00541

VB00516

36

—

—

VB00517

Top cover

6

—

FI10001

FI10001

Side cover

6

—

FI10003

FI10003

Balancing resistor

6

—

PP13034

PP13034

Bus capacitor

72

—

S00335

S00336

DC busbars kit

6

—

FI13329

FI13329

Rectifier module

2

—

FR10823

FR10823

Diode

3

—

PP01177

PP01177

Rectifier board

2

—

S00591

S00591

Keypad 1

SVX/SPX keypad

1

—

KEYPAD-LOC/REM

KEYPAD-LOC/REM

Main AC fan

Fan assembly (left)

6

—

FI13301

FI13301

Inverter

2
2

Driver board
Driver adapter board

2

Fan AC

6

—

PP01080

PP01080

2

Fan fuse

12

—

PP20202

PP20202

Starting cap

6

—

S00520

S00520

Fan driver board AC

6

—

VB00299

VB00299

Isolation transformer

6

—

PP10057

PP10057

2
2
2
2

Main DC fan 1

DC fan

6

—

PP00072

PP00072

DC power supply

6

—

S01017

S01017

Notes
1 Factory recommended spare parts.
2 Select one part number based on the amperage rating of the drive. Please contact EatonCare at 877-ETN-CARE for assistance.

2
2
2
2
2
2
2
2
V6-T2-182

Volume 6—Solid-State Motor Control CA08100007E—May 2014 www.eaton.com

Adjustable Frequency Drives
SPX9000 Drives

2.7

Technical Data and Specifications

2

SPX9000 Drives
Description

Specification

Description

Input Ratings

2

Specification

Control Connections

Input voltage (Vin)

+10%/–15%

Input frequency (fin)

50/60 Hz (variation up to 45–66 Hz)

Connection to power

Once per minute or less (typical operation)

High withstand rating

100 kAIC

Analog input voltage

0 to 10V, R = 200 kohms (–10 to 10V joystick control) resolution
0.1%; accuracy ±1%

Analog input current

0(4) to 20 mA; Ri—250 ohms differential

2
2
2

Digital inputs (6)

Positive or negative logic; 18 to 30 Vdc

Auxiliary voltage

+24V ±15%, max. 250 mA

Output reference voltage

+10V +3%, max. load 10 mA

2

IH rated 100% at 122°F (50°C), FR9 and below
IL rated 100% at 104°F (40°C), FR9 and below
IH/IL 100% at 104°F (40°C), FR10 and above

Analog output

0(4) to 20 mA; RL max. 500 ohms;
resolution 10 bit; Accuracy ±2%

2

Digital outputs

Open collector output, 50 mA/48V

Overload current (IH/IL)

150% IH, 110% IL for 1 min.

Relay outputs

2

Output frequency

0 to 320 Hz

2 programmable Form C relay outputs
switching capacity: 24 Vdc/8A, 250 Vac/8A, 125 Vdc/0.4A

Frequency resolution

0.01 Hz

Initial output current (IH)

250% for 2 seconds

Output Ratings
Output voltage
Continuous output current

0 to Vin

Protections

2

Overcurrent protection

Trip limit 4.0 x IH instantaneously

Overvoltage protection

Yes

Undervoltage protection

Yes

Earth fault protection

In case of earth fault in motor or motor cable, only the
frequency converter is protected

Adjustable with parameter 2.6.9

Input phase supervision

Trips if any of the input phases are missing

Frame 4–6

1 to 16 kHz; default 10 kHz

Motor phase supervision

Trips if any of the output phases are missing

Frame 7–12

1 to 10 kHz; default 3.6 kHz

Overtemperature protection

Yes

Frequency reference

Analog input: Resolution 0.1% (10-bit), accuracy ±1% V/Hz
Panel reference: Resolution 0.01 Hz

Motor overload protection

Yes

Field weakening point

30 to 320 Hz

Acceleration time

0 to 3000 sec.

Deceleration time

0 to 3000 sec.

Braking torque

DC brake: 30% x Tn (without brake option)

Control Characteristics
Control method

Switching frequency

Frequency control (V/f) Open loop: sensorless vector control
Closed loop: frequency control
Closed loop: vector control

Motor stall protection

Yes

Motor underload protection

Yes

Short-circuit protection

Yes (+24V and +10V reference voltages)

Encoder voltages

5V (RS-422), 15V or 24V, depending on the option card

Torque control

Full torque control at all speeds, including zero

Torque accuracy

<2%; <5% down to zero speed

Relative humidity

0 to 95% RH, noncondensing, non-corrosive,
no dripping water

Starting torque

>200%, depending on motor and drive sizing

Master/slave configurations

Full capability

Chemical vapors: IEC 721-3-3, unit in operation, class 3C2;
Mechanical particles: IEC 721-3-3, unit in operation, class 3S2

System analysis

Integrated data logger

PC communication

Fast multiple drive monitoring with PC

Inter-drive communication

High-speed bus (12 Mbits/s)

High-speed applications

Up to 7200 Hz

100% load capacity (no derating) up to 3280 ft (1000m);
1% derating for each 328 ft (100m) above 3280 ft (1000m);
max. 9842 ft (3000m)

Vibration

EN 50178, EN 60068-2-6; 5 to 50 Hz, displacement amplitude
1 mm (peak) at 3 to 15.8 Hz, max. acceleration amplitude
1G at 15.8 to 150 Hz

Shock

EN 50178, EN 60068-2-27 UPS Drop test (for applicable UPS
weights) Storage and shipping: max. 15G, 11 ms (in package)

Enclosure class

NEMA 1/IP21 or NEMA 12/IP54, open chassis/IP20

2

<0.01%, depending on the encoder

–40° to 158°F (–40° to 70°C)

Altitude

2

Incremental or absolute

Storage temperature

Air quality

2

Encoder support
14°F (–10°C), no frost to 122°F (50°C) IH (FR4–FR9)
14°F (–10°C), no frost to 104°F (40°C) IL (FR10 and up)
14°F (–10°C), no frost to 104°F (40°C) IL (all frames)

2
2

Speed error

Ambient operating
temperature

2
2

High Performance Features

Ambient Conditions

2

2
2
2
2
2
2
2
2
2
2
2
2
2

Volume 6—Solid-State Motor Control CA08100007E—May 2014 www.eaton.com

V6-T2-183

2.7
2
2
2

Adjustable Frequency Drives
SPX9000 Drives

Dimensions
Approximate Dimensions in Inches (mm)
9000X Drives
NEMA Type 1/IP21 and NEMA Type 12/IP54, FR4, FR5 and FR6

2

W1
W2

D1

R2

2

R1

2

EATON

2
2

H1

2

H3

H2

2
2
2

R2

2
2
2
2

Knockouts

2
D3

2

D2

2
2

Voltage

Weight
Lbs (kg)

Knockouts at Inches (mm)
N1 (O.D.)

0.3
(7)

11.0 (5)

3 at 10.1 (28)

0.5
(13)

0.3
(7)

17.9 (8)

2 at 1.5 (37)
1 at 10.1 (28)

0.6
(15.5)

0.4
(9)

40.8 (19)

3 at 1.5 (37)

hp (IH)

H1

H2

H3

D1

D2

D3

W1

W2

R1 Dia.

R2 Dia.

12.9
(327)

12.3
(313)

11.5
(292)

7.5
(190)

3.0
(77)

5.0
(126)

5.04
(128)

3.9
(100)

0.5
(13)

16.5
(419)

16.0
(406)

15.3
(389)

8.4
(214)

3.9
(100)

5.8
(148)

5.7
(144)

3.9
(100)

22.0
(558)

21.3
(541)

20.4
(519)

9.3
(237)

4.2
(105)

6.5
(165)

7.7
(195)

5.8
(148)

2

FR4

2

230V

3/4–3

480V

1–5

2

FR5
230V

5–7-1/2

2

480V

7-1/2–15

FR6

2

230V

10–15

2

480V

20–30

575V

2–25

2
2
2
2
V6-T2-184

Volume 6—Solid-State Motor Control CA08100007E—May 2014 www.eaton.com

Adjustable Frequency Drives
SPX9000 Drives

2.7

Approximate Dimensions in Inches (mm)

2

NEMA Type 1/IP21 and NEMA Type 12/IP54 with Flange Kit, FR4, FR5 and FR6

2
2
2

W2

2

Dia. A

2

H2
H1

2

W1

2
2
2

H4
D1

2

H5

2

D2

2
2

H3
Dia. B

H7

2
2

Flange Opening
FR4 to FR6

W5

2

W4 W3

2
H8

H6

2

H9

2

FR4, FR5 and FR6 with Flange Kit
W1

W2

H1

H2

H3

H4

H5

D1

D2

Dia. A

2

4.5 (113)

13.3 (337)

12.8 (325)

12.9 (327)

1.2 (30)

0.9 (22)

7.5 (190)

3.0 (77)

0.3 (7)

2

4.7 (120)

17.0 (434)

16.5 (420)

16.5 (419)

1.4 (36)

0.7 (18)

8.4 (214)

3.9 (100)

0.3 (7)

2

6.7 (170)

22.0 (560)

21.6 (549)

22.0 (558)

1.2 (30)

0.8 (20)

9.3 (237)

4.2 (106)

0.3 (7)

FR4
5.0 (128)
FR5
5.6 (143)
FR6
7.7 (195)

2
2

Flange Opening, FR4 to FR6
W3

2

W4

W5

H6

H7

H8

H9

Dia. B

4.5 (113)

—

12.4 (315)

12.8 (325)

—

0.2 (5)

0.3 (7)

2

4.7 (120)

—

16.2 (410)

16.5 (420)

—

0.2 (5)

0.3 (7)

2

6.7 (170)

6.2 (157)

21.2 (539)

21.6 (549)

0.3 (7)

0.2 (5)

0.3 (7)

2

FR4
4.8 (123)
FR5
5.3 (135)
FR6
7.3 (185)

2
Volume 6—Solid-State Motor Control CA08100007E—May 2014 www.eaton.com

V6-T2-185

2.7
2
2

Adjustable Frequency Drives
SPX9000 Drives

Approximate Dimensions in Inches (mm)
NEMA Type 1/IP21 and NEMA Type 12/IP54, FR7
H1
H2

2
2
2

W2 W1

2
2
2

R2

R1

R2

2
2
Knockouts

2
2

H3

D2

2
2
2

D1
D3

2
2

Voltage

hp (IH)

H1

H2

H3

D1

D2

D3

W1

W2

R1 Dia.

R2 Dia.

Weight
Lbs (kg)

Knockouts at Inches (mm)
N1 (O.D.)

2

230V

20–30

24.8 (630)

24.2 (614)

23.2 (590)

10.1 (257)

3.0 (77)

7.3 (184)

9.3 (237)

7.5 (190)

0.7 (18)

0.4 (9)

77.2 (35)

3 at 1.5 (37)

2

480V

40–60

575V

30–40

2
2
2
2
2
2
2
2
2
2
2
V6-T2-186

Volume 6—Solid-State Motor Control CA08100007E—May 2014 www.eaton.com

Adjustable Frequency Drives
SPX9000 Drives

2.7

Approximate Dimensions in Inches (mm)

2

NEMA Type 1/IP21 and NEMA Type 12/IP54, FR8

2

H1
H2

2
2
2
2

W1 W2

2
2
2
2

R2
R1

2

H3

2
2
2
2

D1

2
2
2
2

Voltage

hp (IH)

D1

H1

H2

H3

W1

W2

R1 Dia.

R2 Dia.

Weight
Lbs (kg)

2

230V

40–60

13.5 (344)

300.1 (764)

28.8 (732)

28.4 (721)

11.5 (291)

10 (255)

0.7 (18)

0.4 (9)

127 (58)

480V

75–125

2

575V

50–75

2
2
2
2
2
2
2
2
2
Volume 6—Solid-State Motor Control CA08100007E—May 2014 www.eaton.com

V6-T2-187

2.7
2
2

Adjustable Frequency Drives
SPX9000 Drives

Approximate Dimensions in Inches (mm)
NEMA Type 1/IP21 and NEMA Type 12/IP54, with Flange Kit, FR7 and FR8
H6

H4

H4

H5

Dia. A

2
2
2

W4 W2

2
2
2

H2
H1

2

W3
W1

H7

2
2
2

D1

2

D2

2
2

H3
H12

2

H9

H9

H10

H11

2
2

Flange Opening
FR7/FR8

W5 W6

W7
Dia. B

2
2
2
2

FR7

2

FR8

2
2

H8

H13
W1

9.3 (237)

11.2 (285)

W2

W3

W4

H1

H2

H3

H4

H5

H6

H7

D1

D2

Dia. A

6.8 (175)

10.6 (270)

10.0 (253)

25.6 (652)

24.9 (632)

24.8 (630)

7.4 (189)

7.4 (189)

0.9 (23)

0.8 (20)

10.1 (257)

4.6 (117)

0.3 (6)

—

14.0 (355)

13.0 (330)

32.8 (832)

—

29.3 (745)

10.2 (258)

10.4 (265)

1.7 (43)

2.2 (57)

13.5 (344)

4.3 (110)

0.4 (9)

Flange Opening, FR7 and FR8
W5

2

FR7

2

FR8

9.2 (233)

11.9 (301)

W6

W7

H8

H9

H10

H11

H12

H13

Dia. B

6.9 (175)

10.0 (253)

24.4 (619)

7.4 (189)

7.4 (189)

1.4 (35)

1.3 (32)

1.0 (25)

0.3 (6)

—

13.0 (330)

31.9 (810)

10.2 (258)

10.4 (265)

—

—

1.3 (33)

0.4 (9)

2
2
2
V6-T2-188

Volume 6—Solid-State Motor Control CA08100007E—May 2014 www.eaton.com

2.7

Adjustable Frequency Drives
SPX9000 Drives

Approximate Dimensions in Inches (mm)

2

NEMA Type 1/IP21 and NEMA Type 12/IP54, FR9
H6

H4

H3

2

W4

W5

2
W2

W3

W1

2
2

PE

W5

B- B+ /R+ R-

2

2
H2

H5

2

D3

2

H1
Dia.

2
2

D1

2

D2

2
Voltage

hp (IH)

W1

W2

W3

W4

H1

H2

H3

H4 1

D1

D2

D3

Dia.

230V

75–100

480V

150–200

18.9
(480)

15.7
(400)

0.4
(9)

2.1
(54)

45.3
(1150)

44.1
(1120)

0.6
(16)

7.4
(188)

14.2
(361.5)

13.4
(340)

11.2
(285)

0.8
(21)

575V

100–175

Weight
Lbs (kg)
321.9 (146)

2
2
2
2

Note
1 Brake resistor terminal box (H6) included when brake chopper ordered.

2
2
2
2
2
2
2
2
2
2
2
2
2

Volume 6—Solid-State Motor Control CA08100007E—May 2014 www.eaton.com

V6-T2-189

2.7
2
2

Adjustable Frequency Drives
SPX9000 Drives

Approximate Dimensions in Inches (mm)
NEMA Type 1/IP21 and NEMA Type 12/IP54, FR9 with Flange Kit
H7

2
2

W5

2

W1

2
2
2
2

Dia.

2
2

D1
D2

2
2

D3

2
2
2

H4

H4

H2

H5

H3

H3

H3

H5

2
2
2

W4
Flange Opening
FR9

W3

W2

2

W4

2
2
2
2

H1

H6

.20 (5)
Dia.
W1

W2

W3

W4

W5

H1

20.9 (530)

20.0 (510)

19.1 (485)

7.9 (200)

0.2 (5.5)

51.7 (1312) 45.3 (1150) 16.5 (420)

H2

H3

H4

H5

H6

H7

D1

D2

D3

Dia.

3.9 (100)

1.4 (35)

0.4 (9)

0.1 (2)

24.9 (362)

13.4 (340)

4.3 (109)

0.8 (21)

2
2
2
2
2
2
V6-T2-190

Volume 6—Solid-State Motor Control CA08100007E—May 2014 www.eaton.com

2.7

Adjustable Frequency Drives
SPX9000 Drives

Approximate Dimensions in Inches (mm)

2

NEMA Type 1/IP21 and NEMA Type 12/IP54, FR10 Freestanding
W7
W4

2

W5
W6

W6

2

W4

2
2

Dia. 3
Dia. 1

Dia. 2

2

D6 D7

D3 D2
D5

2

D4

2

W2
W3

W1

W3

W3 W3

W2

2

D1

2
2
2
2
2
2
2
2

H1
H2

2
2
2

Operator
(Shown with
Optional
Disconnect)

2
2

H3

2
2
hp
Volts (IH)
480V 250–350
690V 200–300

W1

W2

23.43 2.46
(595) (62.5)

W3

W4

W5

W6

W7

H1

H2

H3

D1

4.53
(115)

0.79
(20)

5.95
(151)

2.95
(75)

30.11 79.45 74.80 20.18 23.70
(79)
(2018) (1900) (512.5) (602)

D2

D3

D4

D5

D6

D7

Weight
Dia. 1 Dia. 2 Dia. 3 Lbs (kg)

17.44
(443)

19.02
(483)

0.47
(12)

11.22
(285)

17.60
(447)

20.08
(510)

0.83
(21)

1.89
(48)

0.43
(11)

875 (389)

2
2
2
2
2
2

Volume 6—Solid-State Motor Control CA08100007E—May 2014 www.eaton.com

V6-T2-191

2.7
2
2
2
2

Adjustable Frequency Drives
SPX9000 Drives

Approximate Dimensions in Inches (mm)
FR10 Open Chassis 1
H3
H4

H5
W3

2
2

W2

W1

W5

2
2
2
2

H7

W4

H6
H2
H1

2
2
2
2
2
2

D3

D4

D2

D1

2
2
2
2
2
2

Voltage

hp (IH)

W1

W2

W3

W4

W5

H1

H2

H3

H4

H5

H6

H7

D1

D2

D3

D4

Weight
Lbs (kg)

480V

250–350

575V

200–300

19.7
(500)

16.7
(425)

1.2
(30)

2.6
(67)

12.8
(325)

45.9
(1165)

44.1
(1121)

34.6
(879)

33.5
(850)

0.7
(17)

24.7
(627)

10.8
(275)

19.9
(506)

17.9
(455)

16.7
(423)

16.6
(421)

518
(235)

Note
1 SPX9000X FR12 is built of two FR10 modules. Please refer to SPX9000 installation manual for mounting instructions.

2
2
2
2
2
2
2
2
V6-T2-192

Volume 6—Solid-State Motor Control CA08100007E—May 2014 www.eaton.com

2.7

Adjustable Frequency Drives
SPX9000 Drives

Approximate Dimensions in Inches (mm)

2

NEMA Type 1/IP21, FR11 Freestanding Drive
W5

2

W8
W6 W6 W6 W7 W7 W6 W6 W6

W4

2
2
2

Dia. 3
Dia. 1

Dia. 2

D3

2

D5
D2

2

D4

2

W2
W3

W1

W3

W3

W3

W2

2

D1

2
2
2
2
2
2
2
2

H1
H2

2
2
Operator
(Shown with
Optional
Disconnect)

2
2
2

H3

2
2
hp
Voltage (IH)
480V

400–550

690V

400–500

W1

W2

31.26 2.40
(794) (61)

W3

W4

W5

W6

W7

W8

H1

H2

H3

D1

6.50
(165)

0.79
(20)

3.43
(87)

2.95
(75)

2.52
(64)

1.18
(30)

79.45 74.80 20.18 23.70
(2018) (1900) (512.5) (602)

D2

D3

D4

D5

Dia. 1 Dia. 2 Dia. 3

11.22
(285)

19.09
(485)

0.47
(12)

17.60
(447)

0.83
(21)

1.89
(48)

Weight
Lbs (kg)

0.35 x 0.43 526
(9 x 11)
(239)

2
2
2
2
2
2

Volume 6—Solid-State Motor Control CA08100007E—May 2014 www.eaton.com

V6-T2-193

2.7
2
2

Adjustable Frequency Drives
SPX9000 Drives

Approximate Dimensions in Inches (mm)
FR11 Open Chassis
H2

2

W3

W3

W2

W2

W2

W2

2
2
2
2
2
2

Shown without
terminal cover

2
2

H1

2
2
2
2

W1

2
2
2
2
2
2
2

D1

D2

2
2
2
2

Voltage

hp (IH)

W1

W2

W3

H1

H2

D1

D2

Weight
Lbs (kg)

480V

400–550

27.9 (709)

8.6 (225)

2.6 (67)

45.5 (1155)

33.5 (850)

19.8 (503)

18.4 (468)

833 (378)

575V

400–500

2
2
2
2
V6-T2-194

Volume 6—Solid-State Motor Control CA08100007E—May 2014 www.eaton.com

2.7

Adjustable Frequency Drives
SPX9000 Drives

Approximate Dimensions in Inches (mm)

2

FR13, Open Chassis Inverter
W3

2

D6

2

Dia. 4

2

D8

2

D7

D5
W4 W4 W4 W4 W4 Dia. 1

D1

D2

2

D6

2

W1

2
2
2

H3

H1

2

H4

2
2
2

H2
Dia. 2

Dia. 3
W2

W2

W2

W2

D4
D4

2

H5

2
2
2

Dia. 3

D3

W1

W2

W3

W4

W5

H1

H2

H3

H4

H5

27.87
(708)

5.91
(150)

26.65
(677)

4.57
(116)

3.35
(85)

41.54 2.46 39.86 41.34 0.79
(1055) (62.5) (1012.5) (1050) (20)

2
W5

W5

W5

D1

D2

D3

D4

D5

D6

D7

D8

Dia.
1

Dia.
2

Dia.
3

Dia.
4

Weight
Lbs (kg)

21.77
(553)

0.51
(13)

0.63
(16)

1.97
(50)

1.06
(27)

1.57
(40)

5.91
(150)

9.64
0.35x0.59 0.18
(244.8) (9x15)
(4.6)

0.51
(13)

0.37
(9.5)

683 (310)

2
2
2

Notes
9000X FR14 is built of two FR13 modules. Please refer to SPX9000 installation manual for mounting instructions.
FR13 is built from an inverter module and a converter module. Please refer to SPX9000 installation manual for mounting instructions.

2
2
2
2
2
2
2
2

Volume 6—Solid-State Motor Control CA08100007E—May 2014 www.eaton.com

V6-T2-195

2.7
2
2

Adjustable Frequency Drives
SPX9000 Drives

Approximate Dimensions in Inches (mm)
FR13, Open Chassis Converter
Dia. 3

W3

2

D9

2

D8

2

D7

2
2

D6
Dia. 1 W4

W4

W4

D1

D2

W1

2
2
2
2

H4

H1

H3

2
2
2
2

H2

2

W2

D4

W2

D5 D5

2

H5
Dia. 2

2
2

Dia. 2

2

D3

2
2
2

H2

H3

H4

H5

W5

W1

W2

W3

W4

W5

H1

D1

18.74
(476)

5.91
(150)

17.52
(445)

4.57
(116)

3.35
(85)

41.54 2.46 39.86 41.34 0.69 14.69
(1055) (62.5) (1012.5) (1050) (17.5) (373)

D2

D3

0.51
(13)

0.73 6.42
(18.5) (163)

2

Number of Input Units

2

480V
Catalog Number

hp

Input
Modules

690V
Catalog Number

hp

Input
Modules

SPX800A0-4A2N1

800

2

SPX800A0-5A2N1

800

2

SPX900A0-5A2N1

900

2

SPXH10A0-5A2N1

1000

2

2
2

W5
D4

D6

D7

D8

D9

Dia. 1

2.56
(65)

1.06
(27)

1.57
(40)

5.91
(150)

5.24
(133)

0.35x0.59 0.51
(9x15)
(13)

2
2
2
V6-T2-196

Weight
Dia. 2 Dia. 3 Lbs (kg)

D5

Volume 6—Solid-State Motor Control CA08100007E—May 2014 www.eaton.com

0.37
(9.5)

295 (134)

2.7

Adjustable Frequency Drives
SPX9000 Drives

Approximate Dimensions in Inches (mm)

2

FR13, Open Chassis Converter—900/1000 hp 480V
Dia. 4

2

D9

2

D8

2

D7

2

W3

2

D6
Dia. 1 W4

W4

W4

W4

W4

D1

W1

D2

2
2
2
2
H1

H3

H4

2
2
2
2
2

H2
Dia. 2

W2

W2

W2

D4

W2

D5 D5

H5
Dia. 3

2
2
2
2

D3

W1

W2

W3

W4

W5

H1

H2

H3

H4

H5

D1

27.87
(708)

5.91
(150)

26.65
(677)

4.57
(116)

3.35
(85)

41.54 2.46 39.86
41.34 0.69 14.69
(1055) (62.5) (1012.5) (1050) (17.5) (373)

2
W5

W5

D2

D3

D4

D5

0.51
(13)

0.73 6.42 2.56
(18.5) (163) (65)

W5
D6

D7

D8

Dia.
2

Dia.
3

Dia.
4

Weight
Lbs (kg)

1.06
(27)

1.57
(40)

5.91 5.24 0.35x0.59 0.18
(150) (133) (9x15)
(4.6)

0.51
(13)

0.37
(9.5)

443 (201)

D9

Dia.
1

2
2
2
2

Number of Input Units
480V
Catalog Number

hp

Input
Modules

2

SPX900A0-4A2N1

900

3

SPXH10A0-4A2N1

1000

3

2
2
2
2
2
Volume 6—Solid-State Motor Control CA08100007E—May 2014 www.eaton.com

V6-T2-197

2.7
2
2
2
2

Adjustable Frequency Drives
SPX9000 Drives

Approximate Dimensions in Inches (mm)
AC Choke Dimensions
Choke Types
Catalog Number

Frame Size

Choke Type 1

Catalog Number

Voltage Range 380–500V
SPX 250 4

Choke Type 1

Frame Size

Voltage Range 525–690V

FR10

CHK0400

SPX 200 5

FR10

CHK0261

2

SPX 300 4

CHK0520

SPX 250 5

2

SPX 350 4

CHK0520

SPX 300 5

SPX 400 4

2 x CHK0400

SPX 400 5

2 x CHK0400

SPX 450 5

2 x CHK0400

SPX 500 5

2 x CHK0520

SPX 550 5

SPX 650 4

2 x CHK0520

SPX 600 5

2 x CHK0400

2

SPX 700 4

2 x CHK0520

SPX 700 5

2 x CHK0400

2

2 x CHK0400

SPX 800 5

SPX 900 4

3 x CHK0520

SPX 900 5

2

SPX H10 4

3 x CHK0520

SPX H10 5

4 x CHK0520

SPX H13 5

2

SPX H16 4

6 x CHK0400

SPX H15 5

2

CHK0520

2

SPX 500 4

2

SPX 600 4

FR11

SPX 550 4

SPX 800 4

SPX H12 4

FR12

FR13

FR14

CHK0400
CHK0400
FR11

CHK0520
CHK0520
2 x CHK0400

FR12

2 x CHK0400

FR13

2 x CHK0400
2 x CHK0400
2 x CHK0400

FR14

4 x CHK0400
6 x CHK0400

2
2
2
2

6.50
(165)

6.50
(165)

.24
(6)

2
2

8.03 (204)
1.69
(43)

19.57
(497)

2
2

1

2

1

.79
(20)

2

.83
(21)

2
2

5.70
(145)

2

9.61 (244)

17.57
15.71 (446)
(399)

1.58
(40)

3.03
(77)

2

2

1

3

.79
(20)

2

3

3

2

2

7.88
(200)
.55 (14)

Note
1 Chokes are provided with all FR10–FR14 drives.

2
2
V6-T2-198

Volume 6—Solid-State Motor Control CA08100007E—May 2014 www.eaton.com

Adjustable Frequency Drives
SPX9000 Drives

2.7

Approximate Dimensions in Inches (mm)

2

CHK0400

2
2
2

.24
(6)
4.72
(120)

2
2

4.72
(120)

2

9.37 (238)
1.54
(39)

2

13.79 (350)

1

1

2

1

2
13.94
(354)

2.64
(67)
.75
(19)

.59
(15)

2

16.58
15.08 (421)
(383)

1.18
(30)

.59
(15)

3

3

3

2

2

2

2

2

5.51
(140)

2

5.90
(150)
10.83 (275)

10.30 (262)

2
2

CHK0261

2
2
2

.24
(6)
4.72
(120)

2

4.72
(120)

2

13.79 (350)

2

8.11 (206)
1.54
(39)

2
1

1

2

1

.59
(15)
1.18
(30)

.87
(22)
.59
(15)
.39
(10)

4.25
(108)
9.06 (230)

.75 (19)
Min.

3

3

3

2

2

2

2

14.06
12.56
11.30 (319) (357)
(287)

2
2
2

5.90
(150)
10.83 (275)

2
2

Volume 6—Solid-State Motor Control CA08100007E—May 2014 www.eaton.com

V6-T2-199

2.8
2

Adjustable Frequency Drives
Low Harmonic Drives

Contents

Enclosed Passive Filtered Drives

Description

2

Page

Enclosed Passive Filtered Drives
Application Description . . . . . . . . . . . . . . . . . .
Features and Benefits . . . . . . . . . . . . . . . . . . .
Standards and Certifications . . . . . . . . . . . . . .
Product Identification . . . . . . . . . . . . . . . . . . . .
Catalog Number Selection . . . . . . . . . . . . . . . .
Product Selection . . . . . . . . . . . . . . . . . . . . . . .
Options . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Technical Data and Specifications . . . . . . . . . .
Wiring Diagram . . . . . . . . . . . . . . . . . . . . . . . .
Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . .
Enclosed 18-Pulse Drives . . . . . . . . . . . . . . . . . . .

2
2
2
2
2
2

V6-T2-201
V6-T2-207
V6-T2-207
V6-T2-207
V6-T2-208
V6-T2-209
V6-T2-216
V6-T2-221
V6-T2-223
V6-T2-224
V6-T2-233

2
2
2

Enclosed Passive Filtered Drives

2

Product Description

2
2
2
2
2
2
2
2
2

The enclosed passive filtered
clean power drives from
Eaton’s Electrical Sector
use tuned passive filters
to significantly reduce line
harmonics at the drive input
terminals.
The enclosed passive filtered
drive also delivers True
Power Factor—in addition to
reducing harmonic distortion,
the enclosed passive filtered
drive prevents transformer
overheating and overloading
of breakers and feeders,
which enables the application
of adjustable frequency
drives on generators and
other high impedance power
systems.

2
2

The 9000X family of drives
includes HVX9000, SVX9000,
SLX9000, and SPX9000.
9000X Series drive ratings are
rated for either high overload
(IH) or low overload (IL). IL
indicates 110% overload
capacity for 1 minute out of
10 minutes. IH indicates
150% overload capacity for
1 minute out of 10 minutes.

Enclosed Passive Filtered
Drive Products
●

Standard Enclosed—
covers a wide range of the
most commonly ordered
options. Pre-engineering
eliminates the lead time
normally associated with
customer specific options.
Available configurations
are listed on Pages
V6-T2-207 to V6-T2-222.

●

Modified Standard
Enclosed—applies to
specific customer
requirements that vary
from the Standard
Enclosed offering, such as
the need for an additional
indicating light or minor
modifications to drawings.
Contact your local sales
office for assistance in
pricing and lead time.

2
2
2
2
2
2
2
V6-T2-200

Volume 6—Solid-State Motor Control CA08100007E—May 2014 www.eaton.com

●

Custom Engineered—for
those applications with
more unique or complex
requirements, these are
individually engineered to
the customer’s needs.
Contact your local sales
office for assistance in
pricing and lead time.

Adjustable Frequency Drives
Low Harmonic Drives

2.8

Application Description
Designed to meet the IEEE®
519-1992 requirements for
harmonic distortion, the
enclosed passive filtered

drive is an excellent choice
for small and midsize drives
applications where harmonics
are a concern.

What Are Harmonics?
Take a perfect wave with a fundamental frequency of 60 Hz,
which is close to what is supplied by the power company.
Perfect Wave
Volts
(v)
f(x) = sin(x)

Add a second wave that is five times the fundamental frequency—
300 Hz (typical of frequency added to the line by a fluorescent light).
Second Wave

f(x) = sin(5x)
5

Time
(t)

Combine the two waves. The result is a 60 Hz supply rich in
fifth harmonics.
Resulting Supply
Volts
(v)
f(x) = sin(x) + sin(5x)
5

Time
(t)

Harmonics are the result of
nonlinear loads that convert
AC line voltage to DC.
Examples of equipment that
are non-linear loads are listed
below:
●
AC variable frequency
drives
●
DC drives
●
Fluorescence lighting,
computers, UPS systems
●
Industrial washing
machines, punch presses,
welders, etc.
How Can Harmonics Due to
VFDs Be Diminished?
By applying drives from the
Eaton Clean Power Drives
Family; The HCX9000,
enclosed passive filtered
drive and enclosed 18-pulse
drive.

Time
(t)

Volts
(v)

What Causes Harmonics?

What Are Linear Loads?
Linear loads are primarily
devices that run across the
line and do not add
harmonics. Motors are prime
examples. The downside to
having large motor linear
loads is that they draw more
energy than a VFD, because
of their inability to control
motor speed. In most
applications there is a turn
down valve used with the
motor which will reduce the
flow of the material, without
significantly reducing the load
to the motor. While this
provides some measure of
speed control, it is extremely
inefficient.

2

Why Be Concerned
About Harmonics?
1. Installation and utility
costs increase.
Harmonics cause
damage to transformers
and lower efficiencies
due to the IR loss.
These losses can
become significant (from
16.6–21.6%) which can
have a dramatic effect on
the HVAC systems that
are controlling the
temperatures of the
building where the
transformer and drive
equipment reside.
2. Downtime and loss of
productivity. Telephones
and data transmissions
links may not be
guaranteed to work on
the same power grids
polluted with harmonics.
3. Downtime and
nuisance trips of drives
and other equipment.
Emergency generators
have up to three times
the impedance that is
found in a conventional
utility source. Thus the
harmonic voltage can be
up to three times as
large, causing risk of
operation problems.
4. Larger motors must be
used. Motors running
across the line that are
connected on polluted
power distribution grids
can overheat or operate
at lower efficiency due to
harmonics.
5. Higher installation
costs. Transformers and
power equipment must
be oversized to
accommodate the loss of
efficiencies. This is due
to the harmonic currents
circulating through the
distribution without
performing useful work.

2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2

Volume 6—Solid-State Motor Control CA08100007E—May 2014 www.eaton.com

V6-T2-201

2.8

Adjustable Frequency Drives
Low Harmonic Drives

2

How Does a VFD Convert Three-Phase AC to a
Variable Output Voltage and Frequency?

Guidelines of Meeting IEEE Std. 519-1992
Harmonic Distortion Limits

2

The six-pulse VFD: The
majority of all conventional
drives that are built consist of
a six-pulse configuration. The
figure below represents a sixdiode rectifier design that
converts three-phase utility
power to DC. The inverter
section uses IGBTs to convert
DC power to a simulated AC
sine wave that can vary in
frequency from 0–400 Hz.

The IEEE 519-1992
Specification is a standard
that provides guidelines for
commercial and industrial

2
2
2
2
2

The six-pulse VFD drive
creates harmonic current
distortion. The harmonic
current that is created is
energy that can not be used
by customers and causes
external heat and losses to all
components including other
drives that are on the same
power distribution. The figure
is a 100 hp drive with 45A of
damaging harmonic current.

2

100 hp Six-Diode Rectifier Design

2

Current
Amps

2
2
2
2

1000

500

2
2
2
2
2
2
2
2

Isc/IL

Harmonic Order (Odd Harmonics)
111000

15.0

7.0

6.0

2.5

1.4

20.0

Notes

0

TDD = Total demand distortion is the harmonic current distortion in percent of the maximum
demand load current (15 or 30 minute demand).

–500

ISC = Maximum short-circuit current at the PCC not counting motor contribution.

–1000
0.100

IL = Maximum demand load current for all of the connected loads (fundamental frequency
component) at the PCC. All of the limits are measured at a point of common coupling.

0.10625

2
2

Maximum Harmonic Current Distortion in % of the
Fundamental (120V through 69,000V)

The ratio Isc/IL is the ratio of the short-circuit current available at the
point of common coupling (PCC), to the maximum fundamental load
current. Consequently, as the size of the user load decreases with
respect to the size of the system, the percentage of harmonic current
that the user is allowed to inject into the utility system increases.

2
2

users that are implementing
medium and low voltage
equipment.

0.1125
Time in Seconds

0.11875

0.125

100 hp Six-Pulse Nonproductive Harmonic Current
Current
Amps
1000

500

0

–500

–1000
0.100

0.10625

0.1125
Time in Seconds

0.11875

0.125

Six-Pulse Nonproductive Harmonic Current

2

Six-Pulse Circuit

2

I1 = 100%

I11 = 6.10%

I19 = 1.77%

2

I5 = 22.5%

I13 = 4.06%

I23 = 1.12%

I7 = 9.38%

I17 = 2.26%

I25 = 0.86%

2

Power = 100 hp

Current harmonics

Harmonic current = 45 amps

2
V6-T2-202

Volume 6—Solid-State Motor Control CA08100007E—May 2014 www.eaton.com

2.8

Adjustable Frequency Drives
Low Harmonic Drives

One-Line Diagram for Harmonic Analysis

____Volts

____Volts

2
____Volts

____Volts

2

Source A

2

PCC
Utility Side
AC
Motor

AC
Motor

2
2
2

Utility Side
Transformer

2

Customer
Transformer

____Volts
____kVA
____Isc
____Impedance

____Volts
____kVA
____Isc
____Impedance

AC
Motor

AC
Motor

2
2
2

AC
Motor

Customer
Generator
____Volts
____kVA
____Isc
____Impedance

AC
Motor

2

Generator
Set

2
Source B

2

____AMPS
Total Linear Motor Loads
Total Non-Linear Drive Loads ____AMPS

2

The best way to estimate AFD harmonic contribution to an electrical system is to perform a harmonic analysis based on known system
characteristics. The one line in this figure would provide the data to complete the calculations.
Terms
●
PCC (Point of Common
Coupling) is defined as the
electrical connecting point
between the utility and
multiple customers per the
specifications in IEEE 519
●
POA (Point of Analysis)
is defined as where the
harmonic calculations
are taken
An oscilloscope can make
all measurements at the
PCC or POA to do an on-site
harmonic evaluation.

Harmonic Reduction
Methods to Meet IEEE 519
1. Line Reactor
A line reactor is a three-phase
series inductance on the line
side of an AFD. If a line
reactor is applied on all
AFDs, it is possible to meet
IEEE guidelines where
10–25% of system loads
are AFDs, depending on the
stiffness of the line and the
value of line reactance. Line
reactors are available in
various values of percent
impedance, most typically
1–1.5%, 3% and 5%.
Note: The 9000X drives come
standard with a nominal 3% input
impedance.

2
2

Line Reactor

2
AFD

Motor

2
2

Advantages
●
Low cost
●
Can provide moderate
reduction in voltage and
current harmonics
●
Available in various values
of percent impedance
●
Provides increased input
protection for AFD and its
semiconductors from line
transients

Disadvantages
May not reduce harmonic
levels to below IEEE 5191992 guidelines
●
Voltage drop due to IR loss
●

2
2
2
2
2
2
2
2
2
2
2

Volume 6—Solid-State Motor Control CA08100007E—May 2014 www.eaton.com

V6-T2-203

2.8
2
2
2
2
2

Adjustable Frequency Drives
Low Harmonic Drives

2. Passive Filters
Tuned harmonic filters
involve the series connection
of an inductor with the shunt
connection of an inductor and
capacitor to form a low
impedance path to ground for

a specific range of
frequencies. This path
presents an alternative to the
flow of harmonic currents
back into the utility source.

Enclosed Drive with Integrated Passive Filter

2

Tuned
Harmonic
Capacitor

2

Shunt
Fusing

2

Inverter Section

6-Pulse Diode
Bridge Rectifier
Converter Section

(+) DC

Tuned
Shunt
Reactor

2
2

L1A

1

2

L2A

2
3

2

AC
Motor

L3A
AC Input
Reactor

2
2
2

(–) DC
Dynamic Braking
Transistor

Three-Phase
Input

Bus
Capacitors

2

100 hp Enclosed 480V Drive with Integrated Passive Filter

2

Current
Amps

2
2
2

2

100 hp Enclosed 480V Drive with Integrated Passive Filter
Passive Filter
Current harmonics

200

100

I1 = 100%

I11 = 0.24%

I19 = 0.50%

I5 = 3.76%

I13 = 1.1%

I23 = 0.55%

I7 = 1.65%

I17 = 0.80%

I25 = 0.80%

Power = 100 hp

0

Hc = 8.6 Amps

2
2

Output Transistors
IGBT Section

–100

–200
Time

2
2

Advantages
●
Low cost for smaller
horsepower applications
●
More effective harmonic
attenuation than 12-pulse
drives
●
Provides increased input
protection for AFD from
line transients

2
2
2
2
2
V6-T2-204

Volume 6—Solid-State Motor Control CA08100007E—May 2014 www.eaton.com

Disadvantages
Capacitors age over time,
unlike magnetics
●
Not as effective as
18-pulse drives
●
Challenging to retrofit with
bypass applications
●

Adjustable Frequency Drives
Low Harmonic Drives

3. 12-Pulse Converters
A 12-pulse converter
incorporates two separate
AFD input semiconductor
bridges, which are fed from
30º phase shifted power
sources with identical
impedance. The sources may
be two isolation
transformers, where one is a
delta/wye design (which
provides the phase shift) and

the second a delta/delta
design (which does not phase
shift). The 12-pulse
arrangement allows the
harmonics from the first
converter to cancel the
harmonics of the second. Up
to approximately 85%
reduction of harmonic current
and voltage distortion may be
achieved (over standard

2.8
2

six-pulse converter). This
permits a facility to use a
larger percentage of AFD
loads under IEEE 519-1992
guidelines than allowable
using line reactors or DC
chokes. A harmonic analysis
is required to guarantee
compliance with guidelines.

2
2
2
2
2
2

Basic 12-Pulse Rectifier with “Phase Shifting” Transformer
12-Pulse
Phase-Shifting
Transformer

12-Pulse Diode
Bridge Rectifier
Converter Section

2

Inverter Section

2

(+) DC

2

L1A
L2A
L3A

2

AC
Motor

2

L1B
L2B
L3B

2
2

(-) DC
12-Pulse Diode
Bridge Rectifier
Converter Section

Dynamic Braking
Transistor

Output Transistors
IGBT Section

2

Bus
Capacitors

2

100 hp 480V Drive with 12-Pulse Rectifier

100 hp 480V Drive with 12-Pulse Rectifier

Current
Amps

12-Pulse Circuit

2
2

Current harmonics

200

100

I1 = 100%

I11 = 4.19%

I19 = 0.06%

I5 = 1.25%

I13 = 2.95%

I23 = 0.87%

I7 = 0.48%

I17 = 0.21%

I25 = 0.73%

2
2

Power = 100 hp

0

2

Hc = 20 Amps

–100

–200
Time

Advantages
●
Reasonable cost, although
significantly more than
reactors or chokes
●
Substantial reduction (up to
approx. 85%) in voltage
and current harmonics
●
Provides increased input
protection for AFD and its
semiconductors from line
transients

Disadvantages
Impedance matching of
phase shifted sources is
critical to performance
●
Transformers often require
separate mounting or
larger AFD enclosures
●
May not reduce
distribution harmonic levels
to below IEEE 519-1992
guidelines
●
Cannot retrofit for most
AFDs
●

2
2
2
2
2
2
2
2
2

Volume 6—Solid-State Motor Control CA08100007E—May 2014 www.eaton.com

V6-T2-205

2.8
2
2
2
2
2
2
2

Adjustable Frequency Drives
Low Harmonic Drives

4. Clean Power Drives
When the total load is
comprised of non-linear load
such as drives, and the ratio
is lsc/IL, the greatest
harmonic mitigation is
required. Under these
conditions, the currents
drawn from the supply need
to be sinusoidal and “clean”
such that system
interference and additional

losses are negligible. Eaton’s
Enclosed 18-Pulse clean
power drive uses a phaseshifting auto-transformer with
delta-connected winding that
carries only the ampere-turns
caused by the difference in
load currents. This results in
nine separate phases. In this
type of configuration, the

total kVA rating of the
transformer magnetic system
was only 48% that of the
motor load. A traditional
isolated transformer system,
with multipulse windings,
would require the full kVA
rating to be supported, which
is more common in an MV
step-down transformer.

Basic 18-Pulse Rectifier with Phase-Shifting Auto-Transformer
Inverter Section

18-Pulse SCR
Bridge Rectifier
Converter Section

2

Pre-charge
Circuit

2

(+) DC

2
2
2

1
2
3

A
1

9
1
2
3

8

2
3

N
7

2

4

C
6

2
2
2
2
2
2
2
2
2

AC
Motor

4
5
6
7
8
9

5

2
2

The integrated 18-pulse clean
power drive, with near sine
wave input current and low
harmonics will meet the
requirements of IEEE 5191992 under all practical
operating conditions. The
comparisons with six-pulse
passive filter and 12-pulse
systems are shown on Pages
V6-T2-202, V6-T2-204 and
below.

(–) DC
3-Phase
AC Input

18-Pulse
Phase-Shifting
Auto-Transformer

100 hp 480V Drive with 18-Pulse Rectifiers

Diode Rectifiers

Dynamic Braking
Transistor

Output Transistors
IGBT Section

Bus
Capacitors

100 hp 480V Drive with 18-Pulse Rectifiers
18-Pulse Clean Power

Current
Amps

Current harmonics

200

100

I1 = 100%

I11 = 0.24%

I19 = 1.00%

I5 = 0.16%

I13 = 0.10%

I23 = 0.01%

I7 = 0.03%

I17 = 0.86%

I25 = 0.01%

Power = 100 hp

0

Hc = 5.9 Amps

–100

–200
Time

2
2
2
2
2
2
V6-T2-206

Advantages
●
Effectively guarantees
compliance with IEEE 5191992
●
Provides increased input
protection for AFD and its
semiconductors from line
transients
●
Up to 4 times the harmonic
reduction of 12-pulse
methods
●
Smaller transformer than
isolation transformer used
in 12-pulse converter
●
Minimizes ripple current in
capacitors, doubling
expected capacitor life

Volume 6—Solid-State Motor Control CA08100007E—May 2014 www.eaton.com

Disadvantages
Not as cost effective as
some other methods at
small (<50) horsepower

●

Adjustable Frequency Drives
Low Harmonic Drives

Features and Benefits
New enclosed passive filtered
clean power drive features
include (at 480V):
●

●

●

UL Type 1, UL Type 12, UL
Type 3R and NEMA 12 with
gaskets and filters
Input voltage: 480V, 230V,
575V
Complete range of control,
network and power options

2.8

Standards and Certifications
●

Horsepower range:
●
480V, 7-1/2–400 hp IL
●
230V, 7-1/2–100 hp IL;
consult factory for
details
●
575V, 15–400 hp IL;
consult factory for
details

●

●

Single enclosure for both
drive and filter reduces
field wiring and enables
convenient bypass
installation
Packaged solution ensures
optimal coordination of
drive and filter

●
●
●

UL
cUL
508C

2
2
2
2
2
2
2

Product Identification

2

Enclosed Passive Filtered Drive—UL Type 12, 40 hp

2

SVX9000 Drive

2

Input Reactor

2
2
2

Optional Breaker
Disconnect (P1)

2
2

Shunt Fusing

2
Door Mounted
Keypad

2
Tuned Shunt
Reactor

2
2
2

Tuned Harmonic
Capacitor

2
2
2
2
2
2
2
2
2
2

Volume 6—Solid-State Motor Control CA08100007E—May 2014 www.eaton.com

V6-T2-207

2.8
2
2

Adjustable Frequency Drives
Low Harmonic Drives

Catalog Number Selection
Enclosed Passive Filtered Drives
Build Alphabetically and Numerically

CFX 050 1 4 A A

2
2
2
2
2
2
2

_ _ _ _ _ _ _ _ _ _

Product Family
CFX = Integrated filter clean power drive

K3
K4
K5
K6
KF
KO
L1
L2
LE
P1
P3
P7
P8
PE
PF
PG
PH
PI
PN
RA
RB
RC
RD
RG
S4
S5
S6
S9

Horsepower Rating
007 = 7-1/2 hp 040 = 40 hp
150 = 150 hp
010 = 10 hp
050 = 50 hp
200 = 200 hp
015 = 15 hp
060 = 60 hp
250 = 250 hp
020 = 20 hp
075 = 75 hp
300 = 300 hp
025 = 25 hp
100 = 100 hp
350 = 350 hp
030 = 30 hp
125 = 125 hp
400 = 400 hp

2

Enclosure Rating
1 = UL Type 1
2 = UL Type 12
3 = UL Type 3R
6 = NEMA 12 filtered

2
2

Voltage Rating
1 = 208V
2 = 230V
4 = 480V
5 = 575V (575–600V)

2
2
2

Application—Torque/Braking 1
A = IL/no brake chopper
B = IL/internal brake chopper
D = IH/no brake chopper
E = IH/internal brake chopper

2
2
2

C2
C3
C4
C5
C6
C7

Enclosed Style
A = Enclosed drive

2
2
2
2
2
2
2
2

=
=
=
=
=
=

Notes
1 Brake chopper is standard in 208V, 230V and 480V drives up to FR6; optional in all other drives.
2 Local/remote keypad is included as the standard control panel.
3 Some options are voltage and/or horsepower specific. Consult your Eaton representative for details.
4 See Pages V6-T2-218 and V6-T2-219 for complete descriptions.
5 Includes local/remote speed reference switch.
6 See Pages V6-T2-216 and V6-T2-217 for complete descriptions.
7 Consult Eaton for availability.

2
2
V6-T2-208

Type
Control
Control
Control
Control
Control
Control
Addl. bypass
Control
Light
Addl. bypass
Light
Input
Input
Input
Input
Output
Output
Output
Output
Output
Addl. bypass
Bypass
Bypass
Bypass
Bypass
Bypass
Enclosure
Enclosure
Enclosure
Enclosure

Communication Options 6
Modbus
C8 = Modbus (D9 type connector)
PROFIBUS DP
CA = Johnson Controls N2
LonWorks
CI = Modbus TCP
PROFIBUS DP (D9 Connector)
CJ = BACnet
CANopen (Slave)
CQ = EtherNet/IP
DeviceNet
D3 = RS-232 with D9 connection

Control Options
B1 = 6 DI, 1 ext +24 Vdc/EXT +24 Vdc
B2 = 1 RO (NC-NO), 1 RO (NO), 1 therm
B4 = 1 AI (mA isolated), 2 AO (mA isolated), 1 ext +24 Vdc/EXT +24 Vdc
B5 = 3 RO (NO)
B8 = 1 ext +24 Vdc/EXT +24 Vdc, 3 Pt100
B9 = 1 RO (NO), 5 DI 42–240 Vac input

2

2

Enclosed Options 234
Door-mounted speed potentiometer 5
Door-mounted speed potentiometer with HOA selector
switch 5
3–15 psig follower
HAND/OFF/AUTO switch (22 mm)
MANUAL/AUTO reference switch (22 mm)
START/STOP pushbuttons (22 mm)
Bypass test switch for RA and RB
Standard elapsed time meter
Power, RUN and fault pilot lights
Bypass pilot lights for RA, RB, bypass options
Red RUN light
Input circuit breaker
Input line fuses (200 kAIC)
Input power surge protection
TVSS surge protective device
Output contactor
Output filter
MotoRx (up to 600 ft) 1000 V/μS DV/DT filter
Single overload relay
Dual overload relays
Dual overloads for bypass
Manual HOA bypass controller
Manual IOB bypass controller
Auto transfer HOA bypass controller
Auto transfer IOB bypass controller
Reduced voltage starter for bypass
Floor stand 6 in
Floor stand 22 in
Floor stand 12 in
Space heater

K1
K2

Volume 6—Solid-State Motor Control CA08100007E—May 2014 www.eaton.com

HT
VB

Engineered Options
High temperature rating for 50°C 7
Varnished boards

Adjustable Frequency Drives
Low Harmonic Drives

2.8

Product Selection
When Ordering
●
Select a base catalog
number that meets the
application requirements—
nominal horsepower,
voltage and enclosure
rating. (The enclosed
drive’s continuous output
amp rating should be equal
to or greater than the
motor’s full load amp
rating.) The base enclosed
package includes a
standard drive, doormounted alphanumeric
panel and enclosure.

2
●

The enclosed passive
filtered drive product uses
the term High Overload (IH)
in place of the term
Constant Torque (CT).
Likewise, Low Overload (IL)
is used in place of the term
Variable Torque (VT). The
new terms are a more
precise description of the
rating. The older terms
included ambient
temperature ratings in
addition to overload
ratings. In order to
minimize enclosure size
and offer the highest
ambient temperature
rating, overload and
temperature ratings are
now treated separately.
Ambient temperature
ratings are shown in the
following table.

2

Ambient
Temperature Ratings
Enclosure
Size

IH

IL

B, C, 9 1

40°C

40°C

7, 8

50°C

50°C

●

●

●

2
2
2

If dynamic brake chopper
or control/communication
option is desired, change
the appropriate code in the
base catalog number.
All of the programming is
exactly the same as the
standard SVX9000 drive.
Select enclosed options.
Add the codes as suffixes
to the base catalog number
in alphabetical and numeric
order.

2
2
2
2
2
2

Note
1 For high temperature rating, select
HT option code and contact factory.

2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2

Volume 6—Solid-State Motor Control CA08100007E—May 2014 www.eaton.com

V6-T2-209

2.8
2

208V Drives

2

Enclosed Passive
Filtered Drive

Adjustable Frequency Drives
Low Harmonic Drives

UL Type 1, UL Type 12, UL Type 3R and NEMA 12 Filtered
NEC
Current (A)

Chassis
Frame

UL Type 1
Base Catalog Number

UL Type 12 and NEMA 12 Filtered
Base Catalog Number

UL Type 3R
Base Catalog Number

2

hp

2

7-1/2

24.2

FR5

1

CFX00721BA

CFX00731BA

10

30.8

FR5

1

CFX01021BA

CFX01031BA

2

15

46.2

FR6

1

CFX01521BA

CFX01531BA

59.4

FR6

1

2

20

CFX02021BA

CFX02031BA

25

74.8

FR7

1

CFX02521AA

CFX02531AA

2

30

88

FR7

1

CFX03021AA

CFX03031AA

40

114

FR7

1

CFX04021AA

CFX04031AA

2

50

143

FR8

CFX05011AA

CFX05061AA

CFX05031AA

60

169

FR8

CFX06011AA

CFX06061AA

CFX06031AA

2

75

211

FR8

CFX07511AA

CFX07561AA

CFX07531AA

2

100

273

FR9

CFX10011AA

CFX10061AA

CFX10031AA

High Overload Drive

Low Overload Drive

2

7-1/2

24.2

FR5

1

CFX00721EA

CFX00731EA

10

30.8

FR6

1

CFX01021EA

CFX01031EA

2

15

46.2

FR6

1

CFX01521EA

CFX01531EA

20

59.4

FR7

1

CFX02021DA

CFX02031DA

2

25

74.8

FR7

1

CFX02521DA

CFX02531DA

30

88

FR7

1

CFX03021DA

CFX03031DA

2
2
2

40

114

FR8

CFX04011DA

CFX04061DA

CFX04031DA

50

143

FR8

CFX05011DA

CFX05061DA

CFX05031DA

60

169

FR8

CFX06011DA

CFX06061DA

CFX06031DA

75

211

FR9

CFX07511DA

CFX07561DA

CFX07531DA

100

273

FR9

CFX10011DA

CFX10061DA

CFX10031DA

2

Enclosed Passive Filtered Drive Enclosure

2

Chassis
Frame

UL Type 1
Disconnect Only

With Power Options

UL Type 12
Disconnect Only

With Power Options

UL Type 3R
Disconnect Only

With Power Options

2

FR4

N/A

N/A

B

C

B

C

2

FR5

N/A

N/A

B

C

B

C

FR6

N/A

N/A

B

C

B

C

FR7

N/A

7

C

7

C

D

FR8

7

7

7

7

F

F

2

FR9

8

8

8

8

F

F

2

Enclosure Dimension Drawings

2

Enclosure
Size

UL Type 1 and UL Type 12

UL Type 3R

B

See Page V6-T2-224

See Page V6-T2-226

2

C

See Page V6-T2-225

See Page V6-T2-227

2

D

N/A

See Page V6-T2-228

F

N/A

See Page V6-T2-229

72

See Page V6-T2-230

3

82

See Page V6-T2-231

3

9

See Page V6-T2-232

3

2

2
2

Notes
1 FR5–FR7 drives not available in UL Type 1.
2 Enclosures 7 and 8 are NEMA 12 filtered.
3 Not available for UL Type 3R.

2
2
V6-T2-210

Volume 6—Solid-State Motor Control CA08100007E—May 2014 www.eaton.com

2.8

Adjustable Frequency Drives
Low Harmonic Drives

230V Drives
Enclosed Passive
Filtered Drive

2
UL Type 1, UL Type 12, UL Type 3R and NEMA 12 Filtered
hp

NEC
Current (A)

Chassis
Frame

UL Type 1
Base Catalog Number

UL Type 12 and NEMA 12 Filtered
Base Catalog Number

UL Type 3R
Base Catalog Number

Low Overload Drive
7-1/2

22

FR5

1

CFX00722BA

CFX00732BA

10

28

FR5

1

CFX01022BA

CFX01032BA

15

42

FR6

1

CFX01522BA

CFX01532BA

20

54

FR6

1

CFX02022BA

CFX02032BA

25

68

FR7

1

CFX02522AA

CFX02532AA

30

80

FR7

1

CFX03022AA

CFX03032AA

40

104

FR7

1

CFX04022AA

CFX04032AA

50

130

FR8

CFX05012AA

CFX05062AA

CFX05032AA

60

154

FR8

CFX06012AA

CFX06062AA

CFX06032AA

75

192

FR8

CFX07512AA

CFX07562AA

CFX07532AA

100

248

FR9

CFX10012AA

CFX10062AA

CFX10032AA

22

FR5

1

CFX00722EA

CFX00732EA

10

28

FR6

1

CFX01022EA

CFX01032EA

15

42

FR6

1

CFX01522EA

CFX01532EA

20

54

FR7

1

CFX02022DA

CFX02032DA

25

68

FR7

1

CFX02522DA

CFX02532DA

30

80

FR7

1

CFX03022DA

CFX03032DA

40

104

FR8

CFX04012DA

CFX04062DA

CFX04032DA

50

130

FR8

CFX05012DA

CFX05062DA

CFX05032DA

60

154

FR8

CFX06012DA

CFX06062DA

CFX06032DA

75

192

FR9

CFX07512DA

CFX07562DA

CFX07532DA

100

248

FR9

CFX10012DA

CFX10062DA

CFX10032DA

2
2
2
2
2
2
2
2
2
2
2
2
2

Enclosed Passive Filtered Drive Enclosure

2

Chassis
Frame

UL Type 1
Disconnect Only

With Power Options

UL Type 12
Disconnect Only

With Power Options

UL Type 3R
Disconnect Only

With Power Options

FR4

N/A

N/A

B

C

B

C

FR5

N/A

N/A

B

C

B

C

FR6

N/A

N/A

B

C

B

C

FR7

N/A

7

C

7

C

D

FR8

7

7

7

7

F

F

FR9

8

8

8

8

F

F

UL Type 1 and UL Type 12

UL Type 3R

B

See Page V6-T2-224

See Page V6-T2-226

C

See Page V6-T2-225

See Page V6-T2-227

D

N/A

See Page V6-T2-228

F

N/A

See Page V6-T2-229

72

See Page V6-T2-230

3

82

See Page V6-T2-231

3

9

See Page V6-T2-232

3

2
2
2
2
2
2
2
2

Notes
1 FR5–FR7 drives not available in UL Type 1.
2 Enclosures 7 and 8 are NEMA 12 filtered.
3 Not available for UL Type 3R.

Volume 6—Solid-State Motor Control CA08100007E—May 2014 www.eaton.com

2
2

Enclosure Dimension Drawings
Enclosure
Size

2
2

High Overload Drive
7-1/2

2

2
2
V6-T2-211

2.8
2
2

Adjustable Frequency Drives
Low Harmonic Drives

480V Drives
Enclosed Passive
Filtered Drive

2

Enclosed Passive Filtered Base Drive
hp

NEC
Current (A)

Chassis
Frame

UL Type 1
Base Catalog Number 1

UL Type 12 and NEMA 12 Filtered
Base Catalog Number 1

UL Type 3R
Base Catalog Number 1

Low Overload Drive

2

7-1/2

11

FR4

2

CFX00724BA

CFX00734BA

10

14

FR5

2

CFX01024BA

CFX01034BA

15

21

FR5

2

CFX01524BA

CFX01534BA

2

20

27

FR5

2

CFX02024BA

CFX02034BA

25

34

FR6

2

CFX02524BA

CFX02534BA

2

30

40

FR6

2

CFX03024BA

CFX03034BA

40

52

FR6

2

CFX04024BA

CFX04034BA

2

50

65

FR7

CFX05014AA 3

CFX05024AA

CFX05034AA

2

60

77

FR7

CFX06014AA 3

CFX06024AA

CFX06034AA

75

96

FR7

CFX07514AA 3

CFX07524AA

CFX07534AA

100

124

FR8

CFX10014AA

CFX10064AA

CFX10034AA

125

156

FR8

CFX12514AA

CFX12564AA

CFX12534AA

150

180

FR8

CFX15014AA

CFX15064AA

CFX15034AA

200

240

FR9

CFX20014AA

CFX20064AA

CFX20034AA

2

250

302

FR9

CFX25014AA

CFX25064AA

CFX25034AA

361

FR10

CFX30014AA

CFX30064AA

4

2

300
350

414

FR10

CFX35014AA

CFX35064AA

4

2

400

477

FR10

CFX40014AA

CFX40064AA

4

2

7-1/2

11

FR5

2

CFX00724EA

CFX00734EA

10

14

FR5

2

CFX01024EA

CFX01034EA

2

15

21

FR5

2

CFX01524EA

CFX01534EA

20

27

FR6

2

CFX02024EA

CFX02034EA

2

25

34

FR6

2

CFX02524EA

CFX02534EA

2

30

40

FR6

2

CFX03024EA

CFX03034EA

40

52

FR7

CFX04014DA 3

CFX04024DA

CFX04034DA

2

50

65

FR7

CFX05014DA 3

CFX05024DA

CFX05034DA

60

77

FR7

CFX06014DA 3

CFX06024DA

CFX06034DA

2

75

96

FR8

CFX07514DA

CFX07564DA

CFX07534DA

100

124

FR8

CFX10014DA

CFX10064DA

CFX10034DA

2

125

156

FR8

CFX12514DA

CFX12564DA

CFX12534DA

2

150

180

FR9

CFX15014DA

CFX15064DA

CFX15034DA

200

240

FR9

CFX20014DA

CFX20064DA

CFX20034DA

2

250

302

FR10

CFX25014DA

CFX25064DA

4

300

361

FR10

CFX30014DA

CFX30064DA

4

2

350

414

FR10

CFX35014DA

CFX35064DA

4

2

2
2

High Overload Drive

Notes
1 The integrated filter clean power assembly includes a standard drive, door-mounted local/remote keypad and enclosure.
2 FR4–FR6 drives not available in UL Type 1.
3 This catalog number is used only with power options.
4 Consult factory.

2
2
2
2
2
2
V6-T2-212

Volume 6—Solid-State Motor Control CA08100007E—May 2014 www.eaton.com

2.8

Adjustable Frequency Drives
Low Harmonic Drives

Enclosed Passive Filtered Drive Enclosure
Chassis
Frame

UL Type 1
Disconnect Only

With Power Options

UL Type 12
Disconnect Only

FR4

N/A

N/A

B

FR5
FR6

N/A

N/A

N/A

N/A

FR7

N/A

FR8

7

2

With Power Options

UL Type 3R
Disconnect Only

With Power Options

C

B

C

B

C

B

C

B

C

B

C

7

C

7

C

D

7

7

7

F

F

FR9

8

8

8

8

F

F

FR10

9

9

9

9

1

1

2
2
2
2
2

Enclosure Dimension Drawings
Enclosure
Size

UL Type 1 and UL Type 12

UL Type 3R

B

See Page V6-T2-224

See Page V6-T2-226

C

See Page V6-T2-225

See Page V6-T2-227

D

N/A

See Page V6-T2-228

F

N/A

See Page V6-T2-229

72

See Page V6-T2-230

3

82

See Page V6-T2-231

3

9

See Page V6-T2-232

3

2

2
2
2
2
2

Notes
1 Consult factory.
2 Enclosures 7 and 8 are NEMA 12 filtered.
3 Not available for UL Type 3R.

2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2

Volume 6—Solid-State Motor Control CA08100007E—May 2014 www.eaton.com

V6-T2-213

2.8
2
2

Adjustable Frequency Drives
Low Harmonic Drives

575V Drives
Enclosed Passive
Filtered Drive

2

UL Type 1, UL Type 12, UL Type 3R and NEMA 12 Filtered
hp

NEC
Current (A)

Chassis
Frame

UL Type 1
Base Catalog Number

UL Type 12 and NEMA 12 Filtered
Base Catalog Number

UL Type 3R
Base Catalog Number

Low Overload Drive

2

15

17

FR6

1

CFX01525AA

CFX01535AA

20

22

FR6

1

CFX02025AA

CFX02035AA

25

27

FR6

1

CFX02525AA

CFX02535AA

2

30

32

FR6

1

CFX03025AA

CFX03035AA

40

41

FR7

1

CFX04025AA

CFX04035AA

2

50

52

FR7

1

CFX05025AA

CFX05035AA

60

62

FR8

CFX06015AA

CFX06065AA

CFX06035AA

2

2

75

77

FR8

CFX07515AA

CFX07565AA

CFX07535AA

2

100

99

FR8

CFX10015AA

CFX10065AA

CFX10035AA

125

125

FR9

CFX12515AA

CFX12565AA

CFX12535AA

2

150

144

FR9

CFX15015AA

CFX15065AA

CFX15035AA

200

192

FR9

CFX20015AA

CFX20065AA

CFX20035AA

2

250

242

FR10

CFX25015AA

CFX25065AA

2

300

289

FR10

CFX30015AA

CFX30065AA

2

400

382

FR10

CFX40015AA

CFX40065AA

2

2

High Overload Drive

2

10

14

FR6

1

CFX01025DA

CFX01035DA

2

15

17

FR6

1

CFX01525DA

CFX01535DA

20

22

FR6

1

CFX02025DA

CFX02035DA

2

25

27

FR6

1

CFX02525DA

CFX02535DA

30

32

FR7

1

CFX03025DA

CFX03035DA

2

40

41

FR7

1

CFX04025DA

CFX04035DA

50

52

FR8

CFX05015DA

CFX05065DA

CFX05035DA

2

60

62

FR8

CFX06015DA

CFX06065DA

CFX06035DA

2

75

77

FR8

CFX07515DA

CFX07565DA

CFX07535DA

100

99

FR9

CFX10015DA

CFX10065DA

CFX10035DA

2

125

125

FR9

CFX12515DA

CFX12565DA

CFX12535DA

150

144

FR9

CFX15015DA

CFX15065DA

CFX15035DA

2

200

192

FR10

CFX20015DA

CFX20065DA

2

250

242

FR10

CFX25015DA

CFX25065DA

2

2

300

289

FR10

CFX30015DA

CFX30065DA

2

2

Notes
1 FR6–FR7 drives not available in UL Type 1.
2 Consult factory.

2
2
2
2
2
2
2
2
V6-T2-214

Volume 6—Solid-State Motor Control CA08100007E—May 2014 www.eaton.com

2.8

Adjustable Frequency Drives
Low Harmonic Drives

Enclosed Passive Filtered Drive Enclosure
Chassis
Frame

UL Type 1
Disconnect Only

With Power Options

UL Type 12
Disconnect Only

FR6

N/A

N/A

B

FR7
FR8

N/A

7

7

7

2

With Power Options

UL Type 3R
Disconnect Only

With Power Options

C

B

C

C

7

C

D

7

7

F

F

FR9

8

8

8

8

F

F

FR10

9

9

9

9

1

1

2
2
2
2

Enclosure Dimension Drawings
Enclosure
Size

UL Type 1 and UL Type 12

UL Type 3R

B

See Page V6-T2-224

See Page V6-T2-226

C

See Page V6-T2-225

See Page V6-T2-227

D

N/A

See Page V6-T2-228

F

N/A

See Page V6-T2-229

72

See Page V6-T2-230

3

82

See Page V6-T2-231

3

9

See Page V6-T2-232

3

2

2
2
2
2
2

Notes
1 Consult factory.
2 Enclosures 7 and 8 are NEMA 12 filtered.
3 Not available for UL Type 3R.

2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2

Volume 6—Solid-State Motor Control CA08100007E—May 2014 www.eaton.com

V6-T2-215

2.8
2
2
2

Adjustable Frequency Drives
Low Harmonic Drives

Options
Enclosed Passive Filtered Drive Option Board Kits
The enclosed passive filtered drive series can accommodate a wide selection of expander and
adapter option boards to customize the drive for your application needs. The drive’s control unit is
designed to accept a total of five option boards.

2

The enclosed passive filtered drive series factory-installed standard board configuration includes an A9
I/O board and an A2 relay output board, which are installed in slots A and B.

2

Option Boards

Option Board Kits

2
2
2

Option Kit Description 1

Allowed Slot
Locations 2

Field
Installed

Factory
Installed

SVX Ready Programs

Catalog
Number

Option
Designator

Basic

Local/
Remote

Standard

MSS

PID

Multi-P. PFC

Standard I/O Cards
D E
B C

2 RO (NC/NO)

B

OPTA2

—

■

■

■

■

■

■

■

2

6 DI, 1 DO, 2 AI, 1AO, 1 +10 Vdc ref,
2 ext +24 Vdc/ext +24 Vdc

A

OPTA9

—

■

■

■

■

■

■

■

2

Extended I/O Cards
6 DI

B, C, D, E

OPTB1

B1

—

—

—

—

—

■

■

2

1 RO (NC/NO), 1 RO (NO), 1 therm

B, C, D, E

OPTB2

B2

—

—

—

—

—

■

■

A

1 AI (mA isolated), 2 AO (mA isolated)

B, C, D, E

OPTB4

B4

■

■

■

■

■

■

■

2

3 RO (NO)

B, C, D, E

OPTB5

B5

—

—

—

—

—

■

■

2

3 Pt100 RTD board

B, C, D, E

OPTB8

B8

—

—

—

—

—

■

—

1 RO (NO), 5 DI 42–240 Vac input

B, C, D, E

OPTB9

B9

—

—

—

—

—

■

■

2

Communication Cards 3
Modbus

D, E

OPTC2

C2

■

■

■

■

■

■

■

2

Modbus TCP

D, E

OPTCI

CI

■

■

■

■

■

■

■

2

BACnet

D, E

OPTCJ

CJ

■

■

■

■

■

■

■

EtherNet/IP

D, E

OPTCQ

CQ

■

■

■

■

■

■

■

2

Johnson Controls N2

D, E

OPTC2

CA

■

■

■

■

■

■

■

PROFIBUS DP

D, E

OPTC3

C3

■

■

■

■

■

■

■

2

LonWorks

D, E

OPTC4

C4

■

■

■

■

■

■

■

PROFIBUS DP (D9 connector)

D, E

OPTC5

C5

■

■

■

■

■

■

■

2

CANopen (slave)

D, E

OPTC6

C6

■

■

■

■

■

■

■

2

DeviceNet

D, E

OPTC7

C7

■

■

■

■

■

■

■

Modbus (D9 type connector)

D, E

OPTC8

C8

■

■

■

■

■

■

■

RS-232 with D9 connection

D, E

OPTD3

D3

■

■

■

■

■

■

■

2

Notes
1 AI = Analog Input; AO = Analog Output, DI = Digital Input, DO = Digital Output, RO = Relay Output
2 Option card must be installed in one of the slots listed for that card. Slot indicated in bold is the preferred location.
3 OPTC2 is a multi-protocol option card.

2
2
2
2
2
2
2
2
2
V6-T2-216

Volume 6—Solid-State Motor Control CA08100007E—May 2014 www.eaton.com

Adjustable Frequency Drives
Low Harmonic Drives

Modbus RTU Network
Communications
The Modbus Network Card
OPTC2 is used for connecting
the 9000X Drive as a slave
on a Modbus network. The
interface is connected by
a 9-pin DSUB connector
(female) and the baud rate
ranges from 300 to 19,200
baud. Other communication
parameters include an
address range from 1 to 247;
a parity of None, Odd or
Even; and the stop bit is 1.

DeviceNet Network
Communications
The DeviceNet Network Card
OPTC7 is used for connecting
the 9000X Drive on a
DeviceNet Network. It
includes a 5.08 mm pluggable
connector. Transfer method
is via CAN using a two-wire
twisted shielded cable with
two-wire bus power cable
and drain. The baud rates
used for communication
include 125K baud, 250K
baud and 500K baud.

PROFIBUS Network
Communications
The PROFIBUS Network Card
OPTC3 is used for connecting
the 9000X Drive as a slave
on a PROFIBUS-DP network.
The interface is connected
by a 9-pin DSUB connector
(female). The baud rates
range from 9.6K baud to 12M
baud, and the addresses
range from 1 to 127.

Johnson Controls Metasys N2
Network Communications
The OPTC2 fieldbus board
provides communication
between the 9000X Drive
and a Johnson Controls
Metasys™ N2 network.
With this connection, the
drive can be controlled,
monitored and programmed
from the Metasys system.
The N2 fieldbus is available as
a factory-installed option and
as a field-installable kit.

LonWorks Network
Communications
The LonWorks Network Card
OPTC4 is used for connecting
the 9000X Drive on a
LonWorks network. This
interface uses Standard
Network Variable Types
(SNVT) as data types. The
channel connection is
achieved using a FTT-10A
Free Topology transceiver
via a single twisted transfer
cable. The communication
speed with LonWorks is
78 kBits/s.
CANopen (Slave)
Communications
The CANopen (Slave)
Network Card OPTC6 is used
for connecting the 9000X
Drive to a host system.
According to ISO® 11898
standard cables to be chosen
for CAN bus should have
a nominal impedance of
120 ohms, and specific line
delay of nominal 5 as/m.
120 ohm line termination
resistors required for
installation.

Modbus/TCP Network
Communications
The Modbus/TCP Network
Card OPTCI is used for
connecting the 9000X Drive
to Ethernet networks using
Modbus protocol. It includes
an RJ-45 pluggable
connector. This interface
provides a selection of
standard and custom register
values to communicate drive
parameters. The board
supports 10 Mbps and
100 Mbps communication
speeds. The IP address of
the board is configurable over
Ethernet using a supplied
software tool.

2.8

BACnet Network
Communications
The BACnet Network Card
OPTCJ is used for connecting
the 9000X Drive to BACnet
networks. It includes a 5.08
mm pluggable connector.
Data transfer is Master-Slave/
Token Passing (MS/TP)
RS-485. This interface uses
a collection of 30 Binary
Value Objects (BVOs) and
35 Analog Value Objects
(AVOs) to communicate
drive parameters. The card
supports 9.6, 19.2 and 38.4
Kbaud communication
speeds and supports network
addresses 1 to 127.

2
2
2
2
2
2
2
2
2

Ethernet/IP Network
Communications
The Ethernet/IP Network
Card OPTCK is used for
connecting the 9000X Drive
to Ethernet/Industrial Protocol
networks. It includes an RJ45 pluggable connector. The
interface uses CIP objects to
communicate drive
parameters (CIP is
“Common Industrial
Protocol,” the same protocol
used by DeviceNet). The
board supports 10 Mbps and
100 Mbps communication
speeds. The IP address of
the board is configurable
by Static, BOOTP and
DHCP methods.

2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2

Volume 6—Solid-State Motor Control CA08100007E—May 2014 www.eaton.com

V6-T2-217

2.8

Adjustable Frequency Drives
Low Harmonic Drives

2

Control/Communication Option Descriptions

2

Available Control/Communications Options
Option

Description

Option Type

2

K1

Door-Mounted Speed Potentiometer—Provides the drive with the ability to adjust the frequency reference using a door-mounted potentiometer. This option uses the
10 Vdc reference to generate a 0–10V signal at the analog voltage input signal terminal. When the HOA bypass option is added, the speed is controlled when the HOA
switch is in the HAND position. Without the HOA bypass option, a two-position switch (labeled local/remote) is provided on the keypad to select speed reference from the speed
potentiometer or a remote speed signal.

Control

K2

Door-Mounted Speed Potentiometer with HOA Selector Switch—Provides the drive with the ability to start/stop and adjust the speed reference from doormounted control devices or remotely from customer supplied inputs. In HAND position, the drive will start and the speed is controlled by the door-mounted speed
potentiometer. The drive will be disabled in the OFF position. When AUTO is selected, the drive run and speed control commands are via user-supplied dry contact and
4–20 mA signal.

Control

K3

3–15 psig Follower—Provides a pneumatic transducer which converts a 3–15 psig pneumatic signal to either 0–8 Vdc or a 1–9 Vdc signal interface with the drive.
The circuit board is mounted on the inside of the front enclosure panel and connects to the user’s pneumatic control system via 6 ft (1.8m) of flexible tubing and a 1/4 in
(6.4 mm) brass tube union.

Control

K4

HAND/OFF/AUTO Switch for Non-Bypass Configurations—Provides a three-position selector switch that allows the user to select either a HAND or AUTO mode of
operation. HAND mode is defaulted to keypad operation, and AUTO mode is defaulted to control from an external terminal source. These modes of operation can be
configured via drive programming to allow for alternate combinations of start and speed sources. Start and speed sources include keypad, I/O and fieldbus.

Control

2

K5

MANUAL/AUTO Speed Reference Switch—Provides door-mounted selector switch for MANUAL/AUTO speed reference.

Control

2

K6

START/STOP Pushbuttons—Provide door-mounted START and STOP pushbuttons for either bypass or non-bypass configurations.

Control

KF

Bypass Test Switch for RB and RA—Allows the user to energize the AF drive for testing while operating the motor on the bypass controller. The Test Switch is
mounted on the inside of the enclosure door.

Addl. bypass

KO

Standard Elapsed Time Meter—Provides a door-mounted elapsed run time meter.

Control

L1

Power On, Run and Fault Lights—Provide a white power on light that indicates power to the enclosed cabinets, a green run light and a red fault light that indicates a
drive fault has occurred.

Light

L2

Bypass Pilot Lights for RB, RA Bypass Options—A green light indicates when the motor is running in inverter mode and an amber light indicates when the motor is
running in bypass mode. The lights are mounted on the enclosure door, above the switches.

Addl. bypass

LE

Red Run Pilot Light (22 mm)—Provides a red run pilot light that indicates the drive is running.

Light

P1

2

Input Circuit Breaker—High interrupting circuit breaker that provides a means of short-circuit protection for the power cables between it and the enclosed 18-pulse
Input
drive, and protection from high-level ground faults on the power cable. Allows a convenient means of disconnecting the enclosed 18-pulse drive from the line and the operating
mechanism can be padlocked in the OFF position. This is factory mounted in the enclosure. Standard rating is 65 kAIC at 208/480V. 100 kAIC is available as an option.

P3

2

Input Line Fuses Rated to 200 kAIC—Provide high-level fault protection of the drive input power circuit from the load side of the fuses to the input side of the power
transistors. This option consists of three 200 kA fuses, which are factory mounted in the enclosure.

P7

MOV Surge Suppressor—Provides a Metal Oxide Varistor (MOV) connected to the line side terminals and is designed to clip line side transients.

Input

2

P8

TVSS Surge Protective Device with 50 kA Rating—Provides transient voltage protection eliminating surges and spikes which can damage the diode bridge
of the drive.

Input

2

PC

Capacitor Contactor—This option provides a contactor between the tuned reactor and capacitor to disconnect the capacitor from the circuit when desired, typically at
light or no load conditions. This contactor is wired to a programmable relay output.

Input

2

PE

Output

2

Output Contactor—Provides a means for positive disconnection of the drive output from the motor terminals. The contactor coil is controlled by the drive’s run or
permissive logic. NO auxiliary contacts rated at 10A, 600 Vac are provided for customer use. Bypass options RB and RA include an output contactor as standard.
This option includes a low VA 115 Vac fused control power transformer and is factory mounted in the enclosure.

PF

Output

2

Output Filter—Used to reduce the transient voltage (DV/DT) at the motor terminals. The output filter is recommended for cable lengths exceeding 100 ft (30m) or for a
drive rated at 525–690V. This option is mounted in the enclosure, and may be used in conjunction with a brake chopper circuit.

PG

MotoRx (300–600 ft) 1000 V/μS DV/DT Filter—Used to reduce transient voltage (DV/DT) and peak voltages at the motor terminals. This option is comprised of a 0.5%
line reactor, followed by capacitive filtering and an energy recovery/clamping circuit. Unlike the output filter (see option PF), the MotoRx recovers most of the energy from the
voltage peaks, resulting in a lower voltage drop to the motor, and therefore conserving power. This option is used when the distance between a single motor and the drive
is 300–600 ft (91–183m). This option cannot be used with the brake chopper circuit. The output filter (option PF) should be investigated as an alternative.

Output

PH

Single Overload Relay—Uses a bimetallic overload relay to provide additional overload current protection to the motor on configurations without bypass options. It is
included with the bypass configurations for overload current protection in the bypass mode. The overload relay is mounted within the enclosure, and is manually
resettable. Heater pack included.

Output

PI

Dual Overload Relays—This option is recommended when a single drive is operating two motors and overload current protection is needed for each of the motors. The
standard configuration includes two bimetallic overload relays, each sized to protect a motor with 50% of the drive hp rating. For example, a 100 hp drive would include
two overload relays sized to protect two 50 hp motors. The relays are mounted within the enclosure, and are manually resettable. Heater packs not included.

Output

PN

Dual Overloads for Bypass—This option is recommended when a single drive is operating two motors in the bypass mode and overload current protection is needed
for each of the motors. The standard configuration includes two bimetallic overload relays, each sized to protect a motor with 50% of the drive hp rating. For example, a
100 hp drive would include two overload relays sized to protect two 50 hp motors. The relays are mounted within the enclosure, and are manually resettable.

Addl. bypass

2
2
2
2
2

2
2
2
2

2
2
2
2
2
2
2
2
2

V6-T2-218

Volume 6—Solid-State Motor Control CA08100007E—May 2014 www.eaton.com

Input

2.8

Adjustable Frequency Drives
Low Harmonic Drives

Available Control/Communications Options, continued

2

Option

Description

Option Type

RA

Manual HOA Bypass Controller—The manual HAND/OFF/AUTO (HOA)—three-contactor—bypass option provides a means of bypassing the enclosed passive
filtered drive, allowing the AC motor to be operated at full speed directly from the AC supply line. This option consists of an input HMCP, a fused control power
transformer, and a full voltage bypass starter with a door-mounted HOA selector switch and an INVERTER/BYPASS switch. The HOA switch provides the ability to start
and stop the drive in the inverter mode. IEC type input, bypass and input contactors are provided. The contactors are mechanically and electrically interlocked (see wiring
diagram on Page V6-T2-223).

Bypass

RB

Manual IOB Bypass Controller—The manual INVERTER/OFF/BYPASS (IOB)—three-contactor—bypass option provides a means of bypassing the enclosed passive
filtered drive, allowing the AC motor to be operated at full speed directly from the AC supply line. This option consists of an input HMCP, a fused control power
transformer, and a full voltage bypass starter with a door-mounted IOB selector switch. IEC type input, bypass and input contactors are provided. The contactors are
mechanically and electrically interlocked (see wiring diagram on Page V6-T2-223).

Bypass

RC

Auto Transfer HOA Bypass Controller —The manual HAND/OFF/AUTO (HOA)—three-contactor—bypass option provides a means of bypassing the enclosed passive
filtered drive, allowing the AC motor to be operated at full speed directly from the AC supply line. The circuitry provides an automatic transfer of the load to “across the
line” operation after a drive trip. This option consists of an input HMCP, a fused control power transformer, and a full voltage bypass starter with a door-mounted HOA
selector switch and an INVERTER/BYPASS switch. The HOA switch provides the ability to start and stop the drive in either mode. IEC type input, bypass and input
contactors are provided. The contactors are mechanically and electrically interlocked (see wiring diagram on Page V6-T2-223). Door-mounted pilot lights are provided
that indicate bypass or inverter operation. A green light indicates when the motor is running in inverter mode and an amber light indicates when the motor is running in
bypass mode.
WARNING: The motor may restart when the overcurrent relay is reset when operating in bypass, unless the IOB selector switch is turned to the OFF position.

Bypass

Auto Transfer IOB Bypass Controller—The auto INVERTER/OFF/BYPASS (IOB)—three-contactor—bypass option provides a means of bypassing the enclosed passive
filtered drive, allowing the AC motor to be operated at full speed directly from the AC supply line. The circuitry provides an automatic transfer of the load to “across the
line” operation after a drive trip. This option consists of an input HMCP, a fused control power transformer, and a full voltage bypass starter with a door-mounted IOB
selector switch. IEC type input, bypass and input contactors are provided. The contactors are mechanically and electrically interlocked (see wiring diagram on Page
V6-T2-223). Door-mounted pilot lights are provided that indicate bypass or inverter operation. A green light indicates when the motor is running in inverter mode and an
amber light indicates when the motor is running in bypass mode.
WARNING: The motor may restart when the overcurrent relay is reset when operating in bypass, unless the IOB selector switch is turned to the OFF position.

Bypass

RG

Reduced Voltage Starter for Bypass—Used in conjunction with bypass option RA, RB, RC or RD. This option adds IT. Series reduced voltage soft starter to bypass
assembly for soft starting in bypass mode.

Bypass

2

S4

Floor Stand 6 in—Raises “F” box off the ground 6 in (152.4 mm). Recommended when box is not installed on an appropriate concrete pad.

Enclosure

2

RD

2
2
2
2
2
2
2
2
2

S5

Floor Stand 22 in—Converts a Size B or C, normally wall mounted enclosure to a floor standing enclosure with a height of 22 in (558.8 mm).

Enclosure

S6

Floor Stand 12 in—Converts a Size C or D, normally wall mounted enclosure to a floor standing enclosure with a height of 12 in (304.8 mm).

Enclosure

S9

Space Heater—Prevents condensation from forming in the enclosure when the drive is inactive or in storage. Includes a thermostat for variable temperature control.
Heater requires a customer supplied 115V remote supply source.

Enclosure

2
2
2

Enclosed Drive Options
Conformal (Varnished) Coating 1

2

Control Options
Delivery
Code

Description

Catalog
Number Suffix

2

FR9

FP

Door-mounted speed potentiometer

K1

FR10

FP

Door-mounted speed potentiometer with HOA selector switch

K2

2

Chassis
Frame

Delivery
Code

Chassis
Frame

FR6

FP

FR7

FP

FR8

FP

FR11

FP

3–15 psig follower

K3

—

—

FR12

FP

HOA selector switch

K4

MANUAL/AUTO reference switch

K5

START-STOP pushbuttons

K6

Type D2 control relay

SD

On-delay relay

SE

Off-delay relay

SF

Additional terminal blocks per 4 points

SD

Light Options
Description

2

Catalog
Number Suffix

Power on, run, fault LED lights (22 mm)

L1

Power on, fault LED lights (22 mm)

L3

Green LED run light (22 mm)

LA

Green LED stop light (22 mm)

LD

Red LED run light (22 mm)

LE

Red LED stop light (22 mm)

LF

Red LED fault light (22 mm)

LG

Power on white LED light (22 mm)

LJ

Miscellaneous LED light (22 mm)

LU

2
2
2
2
2
2

Note
1 See catalog number description to order.

2
2
2
2
2

Volume 6—Solid-State Motor Control CA08100007E—May 2014 www.eaton.com

V6-T2-219

2.8

Adjustable Frequency Drives
Low Harmonic Drives

2

Bypass Control Options

480 and 575V Power Options, 7-1/2–400 hp

2

Description

Catalog
Number Suffix

Description

Catalog
Number Suffix

Bypass test switch used with RA and RB

KF

Input breaker

P1

2

Inverter/bypass pilot lights

L2

Input line fusing

P2

2

Input line fuses 200 kAIC

P3

Meter Options

Output contactor

PE

Catalog
Number Suffix

Output filter

PF

KO

MotoRx (300–600 ft) DV/DT filter

PG

KS

Single overload relay

PH
PI

2

Description
Standard elapsed time meter

2

Frequency meter
MP-3000 relay with URTD

KV

Dual overload relays

2

MP-3000 relay with URTD and CTs

KU

Input MOV

P7

2

50 kA surge protective device

P8

Enclosure Options

100 kA surge protective device

P9

2
2

Catalog
Number Suffix

Enclosure
Size
Space Heater 1

208V Bypass Options, 7-1/2–100 hp

7

S9

2

8

S9

Description

Catalog
Number Suffix

9

S9

Manual HOA bypass controller

RA

2

B

S9

IOB bypass controller

RB

C

S9

Auto transfer HOA bypass controller

RC

2

D

S9

Auto transfer IOB bypass controller

RD

F

S9

Reduced voltage starter for bypass

RG

2

Plastic Nameplate

Dual overloads for bypass

PN

2

Floor Stand/Enclosure Size

2

6 in floor stand, size F

S4

22 in floor stand, size B and C

S5

Description

Catalog
Number Suffix

12 in floor stand, size C and D

S6

Manual HOA bypass controller

RA

IOB bypass controller

RB

Auto transfer HOA bypass controller

RC

Auto transfer IOB bypass controller

RD

Reduced voltage starter for bypass

RG

Dual overloads for bypass

PN

2

All

SN

230V Bypass Options, 7-1/2–125 hp

2

208V Power Options, 7-1/2–100 hp

2

Description

Catalog
Number Suffix

Input breaker

P1

2

Input line fusing

P2

Input line fuses 200 kAIC

P3

2

Output contactor

PE

2

Single overload relay

PH

Dual overload relays

2
2
2

480 and 575V Bypass Options, 7-1/2–400 hp
Description

Catalog
Number Suffix

PI

Manual HOA bypass controller

RA

P7

IOB bypass controller

RB

50 kA surge protective device

P8

Auto transfer HOA bypass controller

RC

100 kA surge protective device

P9

Auto transfer IOB bypass controller

RD

Reduced voltage starter for bypass

RG

Dual overloads for bypass

PN

MOV

230V Power Options, 7-1/2–125 hp
Description

Catalog
Number Suffix

2

Input breaker

P1

Input line fusing

P2

2

Input line fuses 200 kAIC

P3

2

Output contactor

PE

Single overload relay

PH

2

Dual overload relays

PI

MOV

P7

2

50 kA surge protective device

P8

100 kA surge protective device

P9

V6-T2-220

Note
1 Requires customer-supplied 115 Vac supply.

Volume 6—Solid-State Motor Control CA08100007E—May 2014 www.eaton.com

Adjustable Frequency Drives
Low Harmonic Drives

2.8

Technical Data and Specifications

2

Enclosed Passive Filtered Drives
Description

Specification

2

Specification

2

Input/Output Interface Features

Primary Design Features
45–66 Hz input frequency

Description

Standard

Setup adjustment provisions

2

Output: AC volts maximum

Input Voltage Base

Remote keypad/display

Standard

Output frequency range

0–320 Hz

Personal computer

Standard

Initial output current (IH)

250% for 2 seconds

2
2

Operator control provisions

Overload (1 minute [IH/IL])

150%/110%

Drive mounted keypad/display

Standard

Enclosure space heater

Optional

Remote keypad/display

Standard

Oversize enclosure

Standard

Conventional control elements

Standard

Output contactor

Optional

Serial communications

Optional

Bypass motor starter

Optional

115 Vac control circuit

Optional

2

Listings

UL, cUL, 508C

Standard

2

Protection Features

2

Speed setting inputs
Keypad

2

Incoming line fuses

Optional

0–10 Vdc potentiometer/voltage signal Standard

AC input circuit disconnect

Optional

4–20 mA isolated

Configurable

Phase rotation insensitive

Standard

4–20 mA differential

Configurable

EMI filter

Standard—FR6 thru FR9 1

3–15 psig

Optional

Input phase loss protection

Standard

2
2

2

Analog outputs

Input overvoltage protection

Standard

Speed/frequency

Standard

Line surge protection

Standard

Torque/load/current

Programmable

Output short-circuit protection

Standard

Motor voltage

Programmable

Output ground fault protection

Standard

Kilowatts

Programmable

Output phase protection

Standard

0–10 Vdc signals

Configurable w/jumpers

Overtemperature protection

Standard

4–20 mA DC signals

Standard

DC overvoltage protection

Standard

Isolated signals

Optional

Drive overload protection

Standard

Discrete outputs

Motor overload protection

Standard

Fault alarm

Programmer software

Optional

Drive running

Standard

Local/remote keypad

Standard

Drive at set speed

Programmable

Keypad lockout

Standard

Optional parameters

14

Fault alarm output

Standard

Dry contacts

Built-in diagnostics

Standard

Surge protective device

Optional

2
2
2
2

Standard

2
2
2

2 relays Form C

Open collector outputs

1

Additional discrete outputs

Optional

2

RS-232

Standard

2

RS-422/485

Optional

DeviceNet™

Optional

Modbus RTU

Optional

CANopen (slave)

Optional

Communications

PROFIBUS-DP

Optional

Lonworks®

Optional

Johnson Controls Metasys™ N2

Optional

EtherNet/IP/Modbus TCP

Optional

BACnet

Optional

2
2
2
2
2
2

Note
1 The EMI filter is optional in FR10.

2
2

Volume 6—Solid-State Motor Control CA08100007E—May 2014 www.eaton.com

V6-T2-221

2.8
2

Adjustable Frequency Drives
Low Harmonic Drives

Enclosed Passive Filtered Drives, continued

Standard I/O Specifications

Description

Description

Specification

Six–digital input programmable

24V: “0” <10V, “1” >18V,Ri >5 kohms

Two–analog input configurable w/
jumpers

Voltage: 0–±10V, Ri >200 kohms
Current: 0 (4)–20 mA, Ri = 250 kohms

Two–digital output programmable

Form C relays 250 Vac or 30 Vdc 2 Amp resistive

Specification

2

Performance Features

2

Sensorless vector control

Standard

Volts/hertz control

Standard

IR and slip compensation

Standard

2
2

Electronic reversing

Standard

One–digital output programmable

Open collector 48 Vdc 50 mA

One–analog output programmable
configurable w/jumper

0–20 mA, RL max. 500 ohms 10 bits ±2%

Dynamic braking

Optional

DC braking

Standard

PID setpoint controller

Programmable

2

Critical speed lockout

Standard

I/O Specifications for Control/Communication Options

Current (torque) limit

Standard

Description

Specification

2

Adjustable acceleration/deceleration

Standard

Analog voltage, input

0–±10V, Ri >200 kilohms

Linear or S curve accel/decel

Standard

Analog current, input

0 (4)–20 mA, Ri = 250 ohms

2

Jog at preset speed

Standard

Digital input

24V: “0” <10V, “1” >18V, Ri >5 kilohms

2

Thread/preset speeds

7

Auxiliary voltage

24V (±20%), max. 50 mA

Automatic restart

Selectable

Reference voltage

10V ±3%, max. 10 mA

2

Coasting motor start

Standard

Analog current, output

Coast or ramp stop selection

Standard

0 (4)–20 mA, RL = 500 kilohms, resolution
10 bit, accuracy <±2%

2

Elapsed time meter

Optional

Analog voltage, output

0 (2)–10V, RL >1 kohm, resolution
10 bit, accuracy <±2%

Standard Conditions for Application and Service

Relay output max. switching voltage

300 Vdc, 250 Vac

Maximum operating ambient temperature 0 to 40°C, contact factory for 50°C 1

Relay output max. switching load

3A/24 Vdc, 300 Vdc, 250 Vac 2

Storage temperature

–40 to 60°C

Relay output max. continuous load

2A rms

Humidity (maximum), non-condensing

95%

Thermistor input

Rtrip = 4.7 kohms

Altitude

100% load capacity (no derating) up to
3280 ft (1000m);
1% derating for each 328 ft (100m) above
3280 ft (1000m); max. 9842 ft (3000m)

Notes
1 Units FR10 rated 40°C.
2 For applications above 3A consult instruction manual.

Line voltage variation

+10/–15%

2

2
2
2
2
2

Line frequency variation

45–66 Hz

2

Efficiency

>96%

Power factor (displacement)

0.99

2
2
2
2
2
2
2
2
2
2
2
2
V6-T2-222

Volume 6—Solid-State Motor Control CA08100007E—May 2014 www.eaton.com

2.8

Adjustable Frequency Drives
Low Harmonic Drives

Wiring Diagram

2

Control Input/Output

2

Basic Application Default I/O Configuration
Reference potentiometer
1–10 kohms

Terminal
1

Remote reference
0(4)–20 mA

mA
READY

Signal

Description

2

Reference output

Voltage for potentiometer, etc.

2

OPTA9
+10Vref

2

AI1+

Analog input, voltage range 0–10 Vdc

Voltage input frequency reference

3

AI1–

I/O Ground

Ground for reference and controls

Analog input, current range 0–20 mA

Current input frequency reference

2
2

4

AI2+

5

AI2–

6

+24V

Control voltage output

Voltage for switches, etc. max 0.1A

7

GND

I/O ground

Ground for reference and controls

8

DIN1

Start forward

Contact closed = start forward

9

DIN2

Start reverse

Contact closed = start reverse

2

10

DIN3

External fault input (programmable)

Contact open = no fault
Contact closed = fault

2

11

CMA

Common for DIN 1–DIN 3

Connect to GND or +24V

12

+24V

Control voltage output

Voltage for switches (see terminal 6)

13

GND

I/O ground

Ground for reference and controls

14

DIN4

Multi-step speed select 1

DIN4

DIN5

Frequency Ref.

15

DIN5

Multi-step speed select 2

Open
Closed
Open
Closed

Open
Open
Closed
Closed

Ref.Vin
Multi-step ref.1
Multi-step ref.2
RefMax

Fault reset

2
2

2
2

16

DIN6

17

CMB

Common for DIN4–DIN6

Connect to GND or +24V

18

AO1+

19

AO1–

Output frequency
Analog output

Programmable
Range 0–20 mA, RL max. 500 ohms

20

DO1

Digital output
READY

Programmable
Open collector, I <50 mA, V <48 Vdc

2
2
2

Contact open = no action
Contact closed = fault reset

2
2
2

OPTA2

RUN

21

RO1

22

RO1

23

RO1

24

RO2

25

RO2

26

RO2

2

Relay output 1
RUN

2
2

Relay output 2
FAULT

2
2
2
2
2
2
2
2
2
Volume 6—Solid-State Motor Control CA08100007E—May 2014 www.eaton.com

V6-T2-223

2.8
2
2

Adjustable Frequency Drives
Low Harmonic Drives

Dimensions
Approximate Dimensions in Inches (mm)
Enclosure Size B—UL Type 12

2

4.00 (101.6)
Minimum Free Air
Space Required

2

3.00 (76.2)
Minimum Air
Space
Required
Both Sides

2
2
2
2
2

H

H1 H2

2
2
2
2
2
2

0.44 (11.2)
Mounting
Holes
(4 Places)

W1
W

D1

D

2
2
2
2
2
2
2

H

H1

H2

W

W1

D

D1

2

40.00
(1016.0)

38.00
(965.2)

36.35
(923.3)

20.92
(531.4)

19.30
(490.2)

16.76
(425.7)

2.34
(59.4)

Approximate
Weight
Lbs (kg)

Approximate
Shipping Weight
Lbs (kg)

185 (84)

229 (104)

2
2
2
2
2
2
2
V6-T2-224

Volume 6—Solid-State Motor Control CA08100007E—May 2014 www.eaton.com

2.8

Adjustable Frequency Drives
Low Harmonic Drives

Approximate Dimensions in Inches (mm)

2

Enclosure Size C—UL Type 12
0.44 (11.2)
Mounting 4.00 (101.6) Minimum
Holes
Free Air Space Required
(4 Places)

0.44 (11.2)
Mounting
Holes
(4 Places)

3.00 (76.2)
Minimum Air Space
Required Both Sides

W1

2

3.00 (76.2)
Minimum Air Space
Required Both Sides

4.00 (101.6) Minimum
Free Air Space Required

2
2
2
2
2

H

H1 H2

2

H2

H3

H4

2
2
2

W1
W

D1

2

D

2
2
D1

W

2

D

2
2
2
H

H1

H2

H3

H4

W

W1

D

D1

52.00
(1320.8)

50.00
(1270.0)

48.35
(1228.1)

72.00
(1828.8)

71.19
(1808.2)

30.92
(785.4)

29.30
(744.2)

16.78
(426.2)

2.34
(59.4)

Approximate
Weight
Lbs (kg)

Approximate
Shipping Weight
Lbs (kg)

320 (145)

435 (197)

2
2
2
2
2
2
2
2
2
2
2
2

Volume 6—Solid-State Motor Control CA08100007E—May 2014 www.eaton.com

V6-T2-225

2.8
2
2

Adjustable Frequency Drives
Low Harmonic Drives

Approximate Dimensions in Inches (mm)
Enclosure Size B—UL Type 3R
W

D

2
2
2
2
2
2
2

H2
H

H1

2

H3

2
2
2
2
2
2

W2
W1

W3

D1

D2
0.44 (11.2)
Mounting
Holes
(4 Places)

2
2
2
2
2
2
2
2
2
2

H

H1

H2

H3

W

W1

W2

W3

D

D1

D2

46.09
(1170.7)

44.45
(1129.0)

42.77
(1086.4)

36.35
(923.3)

26.31
(668.3)

20.92
(531.4)

19.30
(490.2)

2.69
(68.3)

17.74
(450.6)

16.76
(425.7)

3.31
(84.1)

2
2
2
2
V6-T2-226

Volume 6—Solid-State Motor Control CA08100007E—May 2014 www.eaton.com

Approximate
Weight
Lbs (kg)

Approximate
Shipping Weight
Lbs (kg)

235 (107)

290 (132)

2.8

Adjustable Frequency Drives
Low Harmonic Drives

Approximate Dimensions in Inches (mm)

2

Enclosure Size C—UL Type 3R
0.44 (11.2)
Mounting Holes
(4 Places)
W

W
W2

D

2

0.44 (11.2)
Mounting Holes
(4 Places)
D

2
2
2
2
2

H1 H2
H3

2

H2
H3

H

2
H4

H5

2
2
2

W2
W1

2

D1

D2

W3

2
2
2

D1

W1
D2

2
2
2

H

H1

H2

H3

H4

H5

W

W1

W2

W3

D

D1

D2

58.09
(1475.5)

56.45
(1433.8)

54.77
(1391.2)

48.35
(1228.1)

78.09
(1983.5)

77.64
(1972.1)

37.73
(958.3)

30.92
(785.4)

29.30
(744.2)

3.34
(84.8)

17.74
(450.6)

16.77
(426.0)

3.31
(84.1)

Approximate
Weight
Lbs (kg)

Approximate
Shipping Weight
Lbs (kg)

370 (168)

485 (220)

2
2
2
2
2
2
2
2
2
2
2

Volume 6—Solid-State Motor Control CA08100007E—May 2014 www.eaton.com

V6-T2-227

2.8
2
2

Adjustable Frequency Drives
Low Harmonic Drives

Approximate Dimensions in Inches (mm)
Enclosure Size D—UL Type 3R
W1

2

D1

Ø0.44 (11.2)
Mounting Holes
(two places)

W2

2
2
2
2
2
2
2
2

H
H1

2
2
2
2
2
2
2
2

D

W

2
2
2
2
2
2
2
2

H

H1

W

W1

W2

D

D1

76.27
(1937.3)

96.00
(2438.4)

30.92
(784.4)

37.73
(958.3)

29.30
(744.2)

16.76
(424.7)

17.74
(450.6)

Approximate
Shipping Weight
Lbs (kg)
1000 (454)

Note
Shown with optional floor stands.

2
2
2
V6-T2-228

Volume 6—Solid-State Motor Control CA08100007E—May 2014 www.eaton.com

Adjustable Frequency Drives
Low Harmonic Drives

2.8

Approximate Dimensions in Inches (mm)

2

Enclosure Size F
W

2

D

2
2
2
2
2
2
2
H1

H

2
2
2
2
2

W1

2

D1

2
2
2
2
2
H

H1

W

W1

D

D1

93.58
(2376.9)

69.51
(1765.60)

60.00
(1524.0)

48.00
(1219.2)

37.50
(952.5)

26.00
(660.4)

Approximate
Weight
Lbs (kg)

Approximate
Shipping Weight
Lbs (kg)

1700 (771)

1850 (839)

2
2
2
2
2
2
2
2
2
2

Volume 6—Solid-State Motor Control CA08100007E—May 2014 www.eaton.com

V6-T2-229

2.8
2
2

Adjustable Frequency Drives
Low Harmonic Drives

Approximate Dimensions in Inches (mm)
Enclosure Size 7
Exhaust
Air

2
2

For
Cable Entry

20.00
(508.0)

2
2
2

26.25
(666.8)

2

4.79
(121.7)

15.00
(381.0)

Hinged Side
Door Clearance 10.00
at 90°
(254.0)
Top View

2.00
(50.8)

4.00 (101.6) Minimum
Free Air Space Required

2
2
2

Keypad

2

Flanged Disconnect Supplied
with Circuit Breaker
When Specified

2

Operator Elements
When Specified, Mounted
on These Panels

2
2
2

Door Handle
(key-lock optional)
93.92
(2385.6) 90.00
(2286.0)

84.37
(2143.0)

Intake Ventilating Slots
(Filtered on NEMA 12)

2
2
2
2

Quarter Turn Latch
(two places)

2
21.50
(546.1)

2

Side View

2
2

Front View
.56 (14.2) Dia.
Mounting Holes
(4 Places)

3.50
(88.9)

8.00
(203.2)

5.75
(146.1)

2
Construction: UL Type 1 Oversize
Finish: Enclosure – ANSI 61 Gray (Light)

Opening for
Bottom Cable Entry

8.50
(215.9)

18.75
(476.3)

2
2

30.00
(762.0)

15.50
(393.7)

2

1.75 (44.5) Typ.
24.45 (621.0)
28.05 (712.5)
Bottom View

2
2
V6-T2-230

Volume 6—Solid-State Motor Control CA08100007E—May 2014 www.eaton.com

Approximate
Shipping Weight
Lbs (kg)
1000 (454)

2.8

Adjustable Frequency Drives
Low Harmonic Drives

Approximate Dimensions in Inches (mm)

2

Enclosure Size 8
1.25
(31.8)

2

31.00
(787.4)

2

8.25
(209.6)

2

Opening for Top Cable Entry
(2 Places)

2
2
2

Top View

2

4.00 (101.6) Minimum
Free Air Space Required
Keypad

2

Flanged Disconnect Supplied
with Circuit Breaker When Specified

2

Operator Elements When Specified,
Mounted on These Panels

2
2
2

Door Handle
(key-lock optional)
93.50
(2374.9) 90.00
(2286.0)

2

84.37
(2143.0)

2
2

Intake Ventilating Slots
(Filtered on NEMA 12)

2
2

Quarter Turn Latch
(2 Places)

2
2
25.14 (639)
Side View

2

Front View
.56 (14.2) Dia.
Mounting Holes
(4 Places)

9.50
(241.3)

2

Opening for
Bottom Cable Entry

2

12.50
(317.5)

22.47
(570.74)

2

7.73
(196.34)

5.48
(139.19)
Construction: UL Type 1 Oversize
Finish: Enclosure – ANSI 61 Gray (Light)

2

21.45 (544.8)
21.31 (541.3)
48.00 (1219.2)

24.00 (609.6)

3.01 (76.45)
37.47 (951.74)
45.22 (1148.59)
Bottom View

2
Approximate
Shipping Weight
Lbs (kg)

2

1400 (636)

2
2
2

Volume 6—Solid-State Motor Control CA08100007E—May 2014 www.eaton.com

V6-T2-231

2.8
2
2

Adjustable Frequency Drives
Low Harmonic Drives

Approximate Dimensions in Inches (mm)
Enclosure Size 9
43.50 (1104.9)

1.50 (38.1)

2

8.75
(222.3)

2

7.46 x 15.00
(189.5 x 381.0)
Access in Top
(two places)

2
2

90 Max.
Door
Opening

2

27.36
(694.9)

2

29.05
(737.9)

2

90 Max.
Door
Opening

27.06
(687.3)

Top View

2

4.00 (101.6) Minimum
Free Air Space Required

2
2
2
2
2
2
2
2

93.50
(2374.9)

Drive
Circuit Breaker

90.00
(2286.0)
Door Handle
(key-lock optional)

2
2

Access
Plate
(4 places)

2
2

8.50 x 12.00 (215.9 x 304.8)
Bottom Access

ø0.56 (ø14.2) Dia.
Mounting Hole
(five places)

2
2

32.72 (831.1)

Side View

2
2

60.00 (1524.0)
Front View

24.00 (609.6)
25.14 (638.6)

2

25.00
(635.0)

Finish: Enclosure—ANSI 61 Gray (light)
Material: Enclosure and Backplate—
12 ga. = 0.1046 Cold Rolled Steel

18.84
(478.5)
8.20
(208.3)
2.00 (50.8)

2
2

11.93
(303.0)
22.90 (581.7)
46.30 (1176.0)
54.90 (1394.5)
Bottom View

Approximate
Shipping Weight
Lbs (kg)
1800 (817)

2
V6-T2-232

Volume 6—Solid-State Motor Control CA08100007E—May 2014 www.eaton.com

Adjustable Frequency Drives
Low Harmonic Drives

2.8

Contents

Enclosed 18-Pulse Drives

Description

Page

Enclosed Passive Filtered Drives . . . . . . . . . . . . . .
Enclosed 18-Pulse Drives
Application Description . . . . . . . . . . . . . . . . . . .
Features and Benefits . . . . . . . . . . . . . . . . . . .
Catalog Number Selection . . . . . . . . . . . . . . . .
Product Selection . . . . . . . . . . . . . . . . . . . . . . .
Options . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Technical Data and Specifications . . . . . . . . . .
Wiring Diagrams . . . . . . . . . . . . . . . . . . . . . . . .
Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . .

V6-T2-200
V6-T2-234
V6-T2-239
V6-T2-240
V6-T2-241
V6-T2-249
V6-T2-255
V6-T2-257
V6-T2-258

2
2
2
2
2
2
2
2
2
2
2

Enclosed 18-Pulse Drives
Product Description
Eaton’s enclosed 18-pulse
clean power drives use
advanced 18-pulse clean
power technology that
significantly reduces line
harmonics at the drive input
terminals, resulting in one of
the purest sinusoidal
waveforms available.
The enclosed 18-pulse drive
also delivers True Power
Factor—in addition to
reducing harmonic distortion,
the enclosed 18-pulse drive
prevents upstream
transformer overheating and
overloading of breakers and
feeders, enabling the
application of adjustable
frequency drives on
generators and other high
impedance power systems.

All 9000X Series drives are
constant torque rated and
rated for either high overload
(IH) or low overload (IL). IH
indicates 150% overload
capacity for 1 minute out of
10 minutes. IL indicates
110% overload capacity for
1 minute out of 10 minutes.

Enclosed 18-Pulse Drive
Products
●

●

Standard Enclosed—
covers a wide range of the
most commonly ordered
options. Pre-engineering
eliminates the lead time
normally associated with
customer specific options.
Available configurations
are listed on Pages
V6-T2-240 and
V6-T2-249 to V6-T2-254.
Modified Standard
Enclosed—applies to
specific customer
requirements that vary
from the Standard
Enclosed offering, such as
the need for an additional
indicating light or minor
modifications to drawings.
Contact your local sales
office for assistance in
pricing and lead time.

●

Custom Engineered—
for those applications with
more unique or complex
requirements, these are
individually engineered
to the customer’s needs.
Contact your local sales
office for assistance in
pricing and lead time.

2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2

Volume 6—Solid-State Motor Control CA08100007E—May 2014 www.eaton.com

V6-T2-233

2.8
2
2
2

Adjustable Frequency Drives
Low Harmonic Drives

Application Description
Designed to exceed the IEEE®
519-1992 requirements for
harmonic distortion, the
enclosed 18-pulse drive is the
clear choice for applications in

the water, wastewater,
HVAC, industrial and process
industries where harmonics
are a concern.

2

What Are Harmonics?

2

Take a perfect wave with a fundamental frequency of 60 Hz,
which is close to what is supplied by the power company.

2

Perfect Wave

2

Volts
(v)
f(x) = sin(x)

2
2
2
2
2

Add a second wave that is five times the fundamental frequency—
300 Hz (typical of frequency added to the line by a fluorescent light).

2

Second Wave

2

Volts
(v)

f(x) = sin(5x)
5

2
2
2

Time
(t)

2
2
2
2
2

Combine the two waves. The result is a 60 Hz supply rich in
fifth harmonics.

Volts
(v)
f(x) = sin(x) + sin(5x)
5

2
2

What Are Linear Loads?
Linear loads are primarily
devices that run across the
line and do not add
harmonics. Motors are prime
examples. The downside to
having large motor linear
loads is that they draw more
energy than a VFD, because
of their inability to control
motor speed. In most
applications, there is a turn
down valve used with the
motor that will reduce the
flow of the material, without
significantly reducing the load
to the motor. While this
provides some measure of
speed control, it is extremely
inefficient.

Resulting Supply

2
2

Harmonics are the result of
nonlinear loads that convert
AC line voltage to DC.
Examples of equipment that
are non-linear loads are listed
below:
●
AC variable frequency
drives
●
DC drives
●
Fluorescence lighting,
computers, UPS systems
●
Industrial washing
machines, punch presses,
welders, etc.
How Can Harmonics Due to
VFDs Be Diminished?
By purchasing Eaton’s
enclosed 18-pulse drive
that is guaranteed to meet
IEEE Std. 519-1992 Harmonic
Distortion Limits.

Time
(t)

2

What Causes Harmonics?

Time
(t)

2
2
2
V6-T2-234

Volume 6—Solid-State Motor Control CA08100007E—May 2014 www.eaton.com

Why Be Concerned
About Harmonics?
1. Installation and utility
costs increase.
Harmonics cause
damage to transformers
and lower efficiencies
due to the IR loss. These
losses can become
significant and can have a
dramatic effect on the
HVAC systems that are
controlling the
temperatures of the
building where the
transformer and drive
equipment reside.
2. Downtime and loss of
productivity. Telephones
and data transmissions
links may not be
guaranteed to work on
the same power grids
polluted with harmonics.
3. Downtime and
nuisance trips of drives
and other equipment.
Emergency generators
have up to three times
the impedance that is
found in a conventional
utility source. Thus the
harmonic voltage
distortion can be up
to three times as large,
causing risk of operation
problems.
4. Larger motors must be
used. Motors running
across the line that are
connected on polluted
power distribution grids
can overheat or operate
at lower efficiency due
to harmonics.
5. Higher installation
costs. Transformers and
power equipment must
be oversized to
accommodate the loss of
efficiencies. This is due
to the harmonic currents
circulating through the
distribution without
performing useful work.

2.8

Adjustable Frequency Drives
Low Harmonic Drives

How Does a VFD Convert Three-Phase AC to a
Variable Output Voltage and Frequency?

Guidelines of Meeting IEEE Std. 519-1992
Harmonic Distortion Limits

2

The six-pulse VFD: The
majority of all conventional
drives that are built consist
of a six-pulse configuration.
The figure below represents
a six-diode rectifier design that
converts three-phase utility
power to DC. The inverter
section uses IGBTs to convert
DC power to a simulated AC
sine wave that can vary in
frequency from 0–320 Hz.

The IEEE 519-1992
Specification is a standard
that provides guidelines for
commercial and industrial

2

The six-pulse VFD drive
creates harmonic current
distortion. The harmonic
current that is created is
energy that can not be used
by customers and causes
external heat and losses to all
components including other
drives that are on the same
power distribution. See the
curve below showing a
500 hp drive with 167A of
damaging harmonic current.

Six-Diode Rectifier Design
Inverter Section

Six-Pulse Diode
Bridge Rectifier
Converter Section

users that are implementing
medium and low voltage
equipment.

2

Maximum Harmonic Current Distortion in % of the
Fundamental (120V through 69,000V)

2

Isc/IL

Harmonic Order (Odd Harmonics)
h<11
111000

15.0

7.0

6.0

2.5

1.4

20.0

The ratio Isc/IL is the ratio of the short-circuit current available at the
point of common coupling (PCC), to the maximum fundamental load
current. Consequently, as the size of the user load decreases with
respect to the size of the system, the percentage of harmonic current
that the user is allowed to inject into the utility system increases.

(+) DC

L2A
AC
Motor

L1A
L3A

Notes
TDD = Total demand distortion is the harmonic current distortion in percent of the maximum
demand load current (15 or 30 minute demand).
ISC = Maximum short-circuit current at the PCC not counting motor contribution.
IL = Maximum demand load current for all of the connected loads (fundamental frequency
component) at the PCC. All of the limits are measured at a point of common coupling.

(–) DC
Dynamic Braking
Transistor
Bus
Capacitors

2

Output Transistors
IGBT Section

2
2
2
2
2
2
2
2
2
2
2

500 hp Six-Pulse Nonproductive Harmonic Current

2

Current
Amps

2

1000

2
2

500

2

0

2

–500

–1000
0.100

2
0.10625

0.1125
Time in Seconds

0.11875

2

0.125

2

500 hp Six-Pulse Nonproductive Harmonic Current

2

Six-Pulse Circuit

2

Current harmonics
I1 = 100%

I11 = 6.10%

I19 = 1.77%

I5 = 22.5%

I13 = 4.06%

I23 = 1.12%

I7 = 9.38%

I17 = 2.26%

I25 = 0.86%

2
2

Power = 500 hp
Harmonic current = 167 amps

2
Volume 6—Solid-State Motor Control CA08100007E—May 2014 www.eaton.com

V6-T2-235

2.8
2
2
2

Adjustable Frequency Drives
Low Harmonic Drives

One-Line Diagram for Harmonic Analysis

____Volts

____Volts

____Volts

____Volts

Source A

PCC
Utility Side

2

AC
Motor

AC
Motor

AC
Motor

AC
Motor

2
2
2
2
2

Utility Side
Transformer

Customer
Transformer

____Volts
____kVA
____Isc
____Impedance

____Volts
____kVA
____Isc
____Impedance

2
____Volts
____kVA
____Isc
____Impedance

2
2
2

AC
Motor

AC
Motor

Customer
Generator

2

Generator
Set

Source B

____AMPS
Total Linear Motor Loads
Total Non-Linear Drive Loads ____AMPS

2

The best way to estimate AFD harmonic contribution to an electrical system is to perform a harmonic analysis based on known system
characteristics. The one-line in this figure would provide the data to complete the calculations.

2

Terms
●
PCC (Point of Common
Coupling) is defined as the
electrical connecting point
between the utility and
multiple customers per the
specifications in IEEE 519
●
POA (Point of Analysis)
is defined as where the
harmonic calculations
are taken

2
2
2
2
2
2
2

An oscilloscope can make
all measurements at the
PCC or POA do an on-site
harmonic evaluation.

2
2

Harmonic Reduction
Methods to Meet IEEE 519
1. Line Reactor
A line reactor is a three-phase
series inductance on the line
side of an AFD. If a line
reactor is applied on all AFDs,
it is possible to meet IEEE
guidelines where 10–25% of
system loads are AFDs,
depending on the stiffness of
the line and the value of line
reactance. Line reactors are
available in various values of
impedance, most typically
1–1.5%, 3% and 5%.

Line Reactor

AFD

Advantages
●
Low cost
●
Can provide moderate
reduction in voltage and
current harmonics
●
Available in various values
of impedance
●
Provides increased input
protection for AFD and its
semiconductors from line
transients

2
2
2
2
2
V6-T2-236

Volume 6—Solid-State Motor Control CA08100007E—May 2014 www.eaton.com

Motor

Disadvantages
May not reduce harmonic
levels to below IEEE 5191992 guidelines
●
Voltage drop due to IR loss
●

Adjustable Frequency Drives
Low Harmonic Drives

2. 12-Pulse Converters
A 12-pulse converter
incorporates two separate
AFD input semiconductor
bridges, which are fed from
30º phase shifted power
sources with identical
impedance. The sources
may be two isolation
transformers, where one is
a delta/wye design (which
provides the phase shift)

and the second a delta/delta
design (which does not phase
shift). The 12-pulse
arrangement allows the
harmonics from the first
converter to cancel the
harmonics of the second.
Up to approximately 85%
reduction of harmonic current
and voltage distortion may
be achieved (over standard

2.8
2

six-pulse converter). This
permits a facility to use a
larger percentage of AFD
loads under IEEE 519-1992
guidelines than allowable
using line reactors or DC
chokes. A harmonic analysis
is required to guarantee
compliance with guidelines.

2
2
2
2
2
2

Basic 12-Pulse Rectifier with “Phase Shifting” Transformer
12-Pulse
Phase-Shifting
Transformer

12-Pulse Diode
Bridge Rectifier
Converter Section

2

Inverter Section

2

(+) DC

2

L1A
L2A
L3A

2

AC
Motor

2

L1B
L2B
L3B

2
2

(-) DC
12-Pulse Diode
Bridge Rectifier
Converter Section

Dynamic Braking
Transistor

Output Transistors
IGBT Section

2

Bus
Capacitors

2

500 hp 480V Drive with 12-Pulse Rectifier

500 hp 480V Drive with 12-Pulse Rectifier

Current
Amps

12-Pulse Circuit

2
2

Current harmonics

1000

500

I1 = 100%

I11 = 4.19%

I19 = 0.06%

I5 = 1.25%

I13 = 2.95%

I23 = 0.87%

I7 = 0.48%

I17 = 0.21%

I25 = 0.73%

2
2

Power = 500 hp

0

–500

–1000
0.126

2

Hc = 66.2 amps

0.13225

0.1385
Time in Seconds

0.14475

0.151

Advantages
●
Moderate cost, although
significantly more than
reactors or chokes
●
Substantial reduction (up
to approx. 85%) in voltage
and current harmonics
●
Provides increased input
protection for AFD and its
semiconductors from line
transients

Disadvantages
Impedance matching of
phase shifted sources is
critical to performance
●
Transformers often require
separate mounting or
larger AFD enclosures
●
May not reduce
distribution harmonic levels
to below
IEEE 519-1992 guidelines
●
Cannot retrofit for most
AFDs
●

2
2
2
2
2
2
2
2
2

Volume 6—Solid-State Motor Control CA08100007E—May 2014 www.eaton.com

V6-T2-237

2.8
2
2
2
2
2
2
2
2

Adjustable Frequency Drives
Low Harmonic Drives

3. Clean Power Drives
When the total load is of nonlinear, the greatest harmonic
mitigation is required. Under
these conditions, the currents
drawn from the supply need
to be sinusoidal and “clean”
such that system
interference and additional
losses are negligible. Eaton’s
enclosed 18-pulse clean
power drive uses a phaseshifting auto-transformer with
delta-connected winding.
Three of the output phases

Pre-charge
Circuit
(+) DC

2

1
2
3

A

2

1

9
1
2
3

8

2
3

N
7

4

C
6

2

AC
Motor

4
5
6
7
8
9

5

(–) DC

2
2

The integrated 18-pulse
clean power drive, with
near sine wave input current
and low harmonics will meet
the requirements of IEEE
519-1992 under all practical
operating conditions. The
comparisons with six-pulse
and 12-pulse systems
are shown, see Pages
V6-T2-235, V6-T2-237
and V6-T2-238.
Inverter Section

18-Pulse SCR
Bridge Rectifier
Converter Section

2

2

rating to be supported, which
is more common in an MV
step-down transformer.

Basic 18-Pulse Rectifier with Phase Shifting Transformer

2

2

are advanced and three are
retarded. The remaining three
phases of this nine-phase
supply are in phase with the
incoming line. This results in
nine separate phases. In this
type of configuration, the
total required kVA rating of
the transformer is only 48%
of a drive rate isolation
transformer. A traditional
isolated transformer system,
with multipulse windings,
would require the full kVA

3-Phase
AC Input

18-Pulse
Phase-Shifting
Auto-Transformer

Diode Rectifiers

Dynamic Braking
Transistor

Output Transistors
IGBT Section

Bus
Capacitors

2
2
2
2
2
2
2
2
2

500 hp 480V Drive with 18-Pulse Rectifiers

500 hp 480V Drive with 18-Pulse Rectifiers

Current
Amps

18-Pulse Clean Power
Current harmonics

1000

500

I1 = 100%

I11 = 0.24%

I19 = 1.00%

I5 = 0.16%

I13 = 0.10%

I23 = 0.01%

I7 = 0.03%

I17 = 0.86%

I25 = 0.01%

Power = 500 hp

0

Hc = 24 amps

–500

–1000
0.126

2
2
2
2
V6-T2-238

0.13225

0.1385
Time in Seconds

0.14475

0.151

Advantages
●
Virtually guarantees
compliance with
IEEE 519-1992
●
Provides increased input
protection for AFD and its
semiconductors from line
transients
●
Up to four times the
harmonic reduction of
12-pulse methods
●
Smaller transformer than
isolation transformer used
in 12-pulse converter

Volume 6—Solid-State Motor Control CA08100007E—May 2014 www.eaton.com

Disadvantages
Not as cost-effective as
some other methods at
small (<50) horsepower

●

Adjustable Frequency Drives
Low Harmonic Drives

Features and Benefits
Enclosed 18-pulse clean power
drive features include:
●
●

●

●

●

Space optimized enclosure
Simple layout for power
options
Type 1, NEMA 12 with
gaskets and filters,
Type 3R
Input voltage: 480V, 208V,
575V
Complete range of control,
network and power options

2.8

Standards and Certifications
●

●

●

●

Horsepower range:
●
480V, 25–800 hp (consult
factory for larger sizes)
●
208/230V, 25–200 hp
●
575V, 25–800 hp (consult
factory for larger sizes)
Over 15 years of 18-pulse
clean power experience
65 kAIC Standard at 480V
and 208V
100 kAIC optional

2

UL 508C tested, listed and
approved.

2
2
2
2
2
2
2

Product Identification

2

Type 1, 25–150 hp (30 x 90 x 21.50)

2

SVX9000 Drive

2
2
2

Bypass Starter Assembly
(option)

2

Motor Circuit Protector
(standard with bypass options)

2

Door Mounted Keypad

2
2

Pre-Charge Input Contactor

2
18-Pulse Diode Rectifier

2

Input Line Fuses

2
2
2

Input Choke

2
2

18-Pulse Auto-Transformer

2
2
2
2
2
2
Volume 6—Solid-State Motor Control CA08100007E—May 2014 www.eaton.com

V6-T2-239

2.8

Adjustable Frequency Drives
Low Harmonic Drives

2

Catalog Number Selection

2

Enclosed 18-Pulse Drive

2
2
2
2
2

Build options alphabetically and numerically.

CPX 100 1 4 A A

025 = 25 hp
030 = 30 hp
040 = 40 hp
050 = 50 hp
060 = 60 hp
075 = 75 hp

2

K1
K2
K3
K4
K5
K6
KF
KO

Horsepower Rating
100 = 100 hp 350 = 350 hp
125 = 125 hp 400 = 400 hp
150 = 150 hp 500 = 500 hp
200 = 200 hp 600 = 600 hp
250 = 250 hp 700 = 700 hp
300 = 300 hp 800 = 800 hp
Enclosure Rating
1 = Type 1
3 = Type 3R
6 = Type 12 filtered

2
2

Voltage Rating
2 = 230V (208–240V)
4 = 480V
5 = 575V (575–600V)

2
2

Application—Torque/Braking 1
A = IL/no brake chopper
B = IL/internal brake chopper
D = IH/no brake chopper
E = IH/internal brake chopper

2
2
2

L1
L2
LE
P1
P8
PE
PF
PG
PH
PI
PN
RA
RB
RC
RD
RG
S7
S8
S9

Enclosed Style
A = Enclosed drive

2
2
2
2
2
2
2
2

Door-mounted speed potentiometer 5
Door-mounted speed potentiometer with HOA selector switch 5
3–15 psig follower
HAND/OFF/AUTO switch 0.87-inch (22 mm)
MANUAL/AUTO reference switch 0.87-inch (22 mm)
START/STOP pushbuttons 0.87-inch (22 mm)
Bypass test switch for RA and RB
Standard elapsed time meter
Power, RUN and fault pilot lights
Bypass pilot lights for RA, RB, bypass options
Red RUN light
Input disconnect
Surge protective device
Output contactor
Output filter
MotoRx (up to 600 ft [182.9m]) 1000 V/μS DV/DT filter
Single overload relay
Dual overload relays
Dual overloads for bypass
Manual HOA bypass controller
Manual IOB bypass controller
Auto transfer HOA bypass controller
Auto transfer IOB bypass controller
Reduced voltage starter for bypass
10.00-inch (254.0 mm) expansion
20.00-inch (508.0 mm) expansion
Space heater

Control
Control
Control
Control
Control
Control
Addl. bypass
Control
Light
Addl. bypass
Light
Input
Input
Output
Output
Output
Output
Output
Addl. bypass
Bypass
Bypass
Bypass
Bypass
Bypass
Enclosure
Enclosure
Enclosure

Communication Options 6
Modbus®

C2 =
C3 = PROFIBUS® DP
C4 = LonWorks®
C5 = PROFIBUS DP (D9 connector)
C6 = CANopen (slave)
C7 = DeviceNet™
C8 = Modbus (D9 Type connector)

CA =
CI =
CJ =
CQ =
D3 =

Johnson Controls N2
Modbus TCP
BACnet
EtherNet/IP
RS-232 with D9 connection

Control Options
B1 = 6 DI, 1 ext +24 Vdc/ext +24 Vdc
B2 = 1 RO (NC/NO), 1 RO (NO), 1 therm
B4 = 1 AI (mA isolated), 2 AO (mA isolated), 1 ext +24 Vdc/EXT +24 Vdc
B5 = 3 RO (NO)
B8 = 1 ext +24 Vdc/ext +24 Vdc, 3 Pt100
B9 = 1 RO (NO), 5 DI 42–240 Vac input

2

2

Type

Enclosed Options 234

Product Family
CPX = Clean power 18-pulse
enclosed drives

HT
VB

Engineered Options
High temperature rating for 50°C (FR10 and above) 7
Varnished boards

Notes
1 Brake chopper is standard in drives up to 30 hp I or 40 hp I at 480V. It is optional in larger drives.
H
L
2 Local/remote keypad is included as the standard control panel.
3 Some options are voltage and/or horsepower specific. Consult your Eaton representative for details.
4 See Pages V6-T2-251 and V6-T2-252 for complete descriptions.
5 Includes local/remote speed reference switch.
6 See Pages V6-T2-249 and V6-T2-250 for complete descriptions.
7 Consult Eaton for availability.

2
2
2
2
2
V6-T2-240

Volume 6—Solid-State Motor Control CA08100007E—May 2014 www.eaton.com

Adjustable Frequency Drives
Low Harmonic Drives

2.8

Product Selection

2

When Ordering
●

Select a base catalog
number that meets the
application requirements—
nominal horsepower,
voltage and enclosure
rating. (The enclosed
drive’s continuous output
amp rating should be equal
to or greater than the
motor’s full load amp
rating.) The base-enclosed
package includes a
standard drive, doormounted alphanumeric
panel and enclosure.

●

The enclosed 18-pulse
drive product uses the
term High Overload (IH) in
place of the term Constant
Torque (CT). Likewise, Low
Overload (IL) is used in
place of the term Variable
Torque (VT). The new
terms are a more precise
description of the rating.
The older terms included
ambient temperature
ratings in addition to
overload ratings. In order to
minimize enclosure size
and offer the highest
ambient temperature

rating, overload and
temperature ratings are
now treated separately.
Ambient temperature
ratings are shown in the
table below. Consult the
factory for 50°C ratings of
FR10 and above.
Ambient Temperature
Ratings
Frame
Size

IH

IL

FR4–FR9

50°C

50°C

FR10 and above

40°C

40°C

●

●

●

If dynamic brake chopper
or control/communication
option is desired, change
the appropriate code in the
base catalog number.
All of the programming is
exactly the same as the
standard SVX9000 drive.
Select enclosed options.
Add the codes as suffixes
to the base catalog number
in alphabetical and numeric
order.

2
2
2
2
2
2
2
2

208/230V Drives
Enclosed 18-Pulse
Drive

2

2

Enclosed 18-Pulse Base Drive Type 1
Enclosure
Size 1

Current
(A)

Chassis
Frame

Base Catalog
Number 3

25

75

FR7

CPX02512AA

30

88

FR7

CPX03012AA

40

114

FR7

CPX04012AA

50

140

FR8

CPX05012AA

hp 2

2
2

Low Overload Drive
7

8
9

10

60

170

FR8

CPX06012AA

75

205

FR8

CPX07512AA

100

300

FR9

CPX10012AA

2
2
2
2
2

125

340

FR8T

CPX12512AA

150

410

FR8T

CPX15012AA

200

522

FR9T

CPX20012AA

2

25

75

FR7

CPX02512DA

2

30

88

FR7

CPX03012DA

40

114

FR8

CPX04012DA

High Overload Drive
7

50

140

FR8

CPX05012DA

60

170

FR8

CPX06012DA

8

75

205

FR9

CPX07512DA

9

100

300

FR8T

CPX10012DA

125

340

FR8T

CPX12512DA

10

150

410

FR9T

CPX15012DA

200

522

FR9T

CPX20012DA

2
2
2
2
2
2

Notes
1 See enclosure dimensions beginning on Page V6-T2-258.
2 hp ratings are provided as a guideline. Drives should be sized per motor nameplate FLA.
3 The 18-pulse clean power assembly includes a standard drive, door-mounted local/remote keypad and enclosure.

2
2
2
2

Volume 6—Solid-State Motor Control CA08100007E—May 2014 www.eaton.com

V6-T2-241

2.8
2

Enclosed 18-Pulse
Drive

2

Adjustable Frequency Drives
Low Harmonic Drives

Enclosed 18-Pulse Base Drive NEMA 12 Filtered
Enclosure
Size 1

Current
(A)

Chassis
Frame

Base Catalog
Number 3

25

75

FR7

CPX02562AA

30

88

FR7

CPX03062AA

40

114

FR7

CPX04062AA

hp 2

Low Overload Drive

2

7

2
2
2

8

2

9

2

10

50

140

FR8

CPX05062AA

60

170

FR8

CPX06062AA

75

205

FR8

CPX07562AA

100

300

FR9

CPX10062AA
CPX12562AA

125

340

FR8T

150

410

FR8T

CPX15052AA

200

522

FR9T

CPX20062AA

25

75

FR7

CPX02562DA

30

88

FR7

CPX03062DA

40

114

FR8

CPX04062DA

50

140

FR8

CPX05062DA
CPX06062DA

High Overload Drive

2

7

2
2

60

170

FR8

8

75

205

FR9

CPX07562DA

2

9

100

300

FR8T

CPX10062DA

125

340

FR8T

CPX12562DA

2

10

150

410

FR9T

CPX15062DA

200

522

FR9T

CPX20062DA

2

2
2

Enclosed 18-Pulse Base Drive Type 3R 4
Enclosure
Size 1

2

Current
(A)

Chassis
Frame

Base Catalog
Number 3

25

75

FR7

CPX02532AA

30

88

FR7

CPX03032AA

40

114

FR7

CPX04032AA

hp 2

Low Overload Drive

2

7

2
2
2

50

140

FR8

CPX05032AA

60

170

FR8

CPX06032AA
CPX07532AA

75

205

FR8

2

8

100

300

FR9

CPX10032AA

9

125

340

FR8T

CPX12532AA

2

High Overload Drive
25

75

FR7

CPX02532DA

2

30

88

FR7

CPX03032DA

2

40

114

FR8

CPX04032DA

50

140

FR8

CPX05032DA
CPX06032DA

7

2
2

60

170

FR8

8

75

205

FR9

CPX07532DA

9

100

300

FR8T

CPX10032DA

Notes
1 See enclosure dimensions beginning on Page V6-T2-258.
2 hp ratings are provided as a guideline. Drives should be sized per motor nameplate FLA.
3 The 18-pulse clean power assembly includes a standard drive, door-mounted local/remote keypad and enclosure.
4 All Type 3R drives use the Size F enclosure.

2
2
2
V6-T2-242

Volume 6—Solid-State Motor Control CA08100007E—May 2014 www.eaton.com

Adjustable Frequency Drives
Low Harmonic Drives

2.8

480V Drives
Enclosed 18-Pulse
Drive

2
Enclosed 18-Pulse Base Drive Type 1
Enclosure
Size 1

Current
(A)

Chassis
Frame

Base Catalog
Number 3

25

38

FR6

CPX02514BA

30

46

FR6

CPX03014BA

40

61

FR6

CPX04014BA

50

72

FR7

CPX05014AA

hp 2

2
2

Low Overload Drive
7

8

9

10

11

60

87

FR7

CPX06014AA

75

105

FR7

CPX07514AA

100

140

FR8

CPX10014AA

125

170

FR8

CPX12514AA

150

205

FR8

CPX15014AA

200

261

FR9

CPX20014AA

250

300

FR9

CPX25014AA

300

385

FR10

CPX30014AA

350

460

FR10

CPX35014AA

400

520

FR10

CPX40014AA

500

590

FR11

CPX50014AA

550

650

FR11

CPX55014AA

600

730

FR11

CPX60014AA

650

820

FR11

CPX65014AA

700

920

FR12

CPX70014AA

800

1030

FR12

CPX80014AA

25

38

FR6

CPX02514EA

30

46

FR6

CPX03014EA

40

61

FR7

CPX04014DA

50

72

FR7

CPX05014DA

60

87

FR7

CPX06014DA

75

105

FR8

CPX07514DA

100

140

FR8

CPX10014DA

2
2
2
2
2
2
2
2
2
2
2
2

High Overload Drive
7

125

170

FR8

CPX12514DA

8

150

205

FR9

CPX15014DA

200

245

FR9

CPX20014DA

9

250

300

FR10

CPX25014DA

300

385

FR10

CPX30014DA

10

11

350

460

FR10

CPX35014DA

400

520

FR11

CPX40014DA

500

590

FR11

CPX50014DA

550

650

FR11

CPX55014DA

600

720

FR12

CPX60014DA

650

820

FR12

CPX65014DA

700

840

FR12

CPX70014DA

2
2
2
2
2
2
2
2
2
2
2
2

Notes
1 See enclosure dimensions beginning on Page V6-T2-258.
2 hp ratings are provided as a guideline. Drives should be sized per motor nameplate FLA.
3 The 18-pulse clean power assembly includes a standard drive, door-mounted local/remote keypad and enclosure.

2
2
2

Volume 6—Solid-State Motor Control CA08100007E—May 2014 www.eaton.com

V6-T2-243

2.8
2

Enclosed 18-Pulse
Drive

Adjustable Frequency Drives
Low Harmonic Drives

Enclosed 18-Pulse Base Drive NEMA 12 Filtered
Current
(A)

Chassis
Frame

Base Catalog
Number 3

25

38

FR6

CPX02564BA

30

46

FR6

CPX03064BA

40

61

FR6

CPX04064BA

2

50

72

FR7

CPX05064AA

60

87

FR7

CPX06064AA

2

75

105

FR7

CPX07564AA

100

140

FR8

CPX10064AA

2

Enclosure
Size 1

hp 2

Low Overload Drive

2

7

2

2
2

8

2

9

2
2

10

125

170

FR8

CPX12564AA

150

205

FR8

CPX15064AA

200

261

FR9

CPX20064AA

250

300

FR9

CPX25064AA

300

385

FR10

CPX30064AA

350

460

FR10

CPX35064AA

400

520

FR10

CPX40064AA

500

590

FR11

CPX50064AA
CPX55064AA

550

650

FR11

600

730

FR11

CPX60064AA

650

820

FR11

CPX65064AA

700

920

FR12

CPX70064AA

800

1030

FR12

CPX80064AA

25

38

FR6

CPX02564EA

2

30

46

FR6

CPX03064EA

40

61

FR7

CPX04064DA

2

50

72

FR7

CPX05064DA

60

87

FR7

CPX06064DA

75

105

FR8

CPX07564DA

2
2

11

2

High Overload Drive

2

7

2
2
2

8

2

9

2
10

2
2

11

2
2

100

140

FR8

CPX10064DA

125

170

FR8

CPX12564DA

150

205

FR9

CPX15064DA

200

245

FR9

CPX20064DA
CPX25064DA

250

300

FR10

300

385

FR10

CPX30064DA

350

460

FR10

CPX35014DA

400

520

FR11

CPX40064DA

500

590

FR11

CPX50064DA
CPX55064DA

550

650

FR11

600

720

FR12

CPX60064DA

650

820

FR12

CPX65064DA

700

840

FR12

CPX70064DA

Notes
1 See enclosure dimensions beginning on Page V6-T2-258.
2 hp ratings are provided as a guideline. Drives should be sized per motor nameplate FLA.
3 The 18-pulse clean power assembly includes a standard drive, door-mounted local/remote keypad and enclosure.

2
2
2
2
V6-T2-244

Volume 6—Solid-State Motor Control CA08100007E—May 2014 www.eaton.com

Adjustable Frequency Drives
Low Harmonic Drives

Enclosed 18-Pulse
Drive

2.8

Enclosed 18-Pulse Base Drive Type 3R 1
Enclosure
Size 2

hp 3

Current
(A)

Chassis
Frame

Base Catalog
Number 4

2
2

Low Overload Drive
7

8

25

38

FR6

CPX02534AA

30

46

FR6

CPX03034AA

40

61

FR6

CPX04034AA

50

72

FR7

CPX05034AA

2
2
2

60

87

FR7

CPX06034AA

75

105

FR7

CPX07534AA

100

140

FR8

CPX10034AA

125

170

FR8

CPX12534AA

150

205

FR8

CPX15034AA

200

261

FR9

CPX20034AA

250

300

FR9

CPX25034AA

2

25

38

FR6

CPX02534DA

30

46

FR6

CPX03034DA

2

40

61

FR7

CPX04034DA

50

72

FR7

CPX05034DA

60

87

FR7

CPX06034DA

75

105

FR8

CPX07534DA

100

140

FR8

CPX10034DA

2
2
2

High Overload Drive
7

8

125

170

FR8

CPX12534DA

150

205

FR9

CPX15034DA

200

245

FR9

CPX20034DA

2
2
2
2
2
2

Notes
1 All Type 3R drives use the Size F enclosure.
2 See enclosure dimensions beginning on Page V6-T2-258.
3 hp ratings are provided as a guideline. Drives should be sized per motor nameplate FLA.
4 The 18-pulse clean power assembly includes a standard drive, door-mounted local/remote keypad and enclosure.

2
2
2
2
2
2
2
2
2
2
2
2
2
2

Volume 6—Solid-State Motor Control CA08100007E—May 2014 www.eaton.com

V6-T2-245

2.8
2

575V Drives

2

Enclosed 18-Pulse
Drive

Adjustable Frequency Drives
Low Harmonic Drives

Enclosed 18-Pulse Base Drive Type 1
Current
(A)

Chassis
Frame

Base Catalog
Number 3

25

27

FR6

CPX02515AA

30

34

FR6

CPX03015AA

2

40

41

FR7

CPX04015AA

2

50

52

FR7

CPX05015AA

60

62

FR8

CPX06015AA

75

80

FR8

CPX07515AA

100

100

FR8

CPX10015AA

125

125

FR9

CPX12515AA

150

144

FR9

CPX15015AA

200

208

FR9

CPX20015AA
CPX25015AA

2

Enclosure
Size 1

hp 2

Low Overload Drive

2

7

2
2

8

2
9

2
2

10

2

11

2

250

261

FR10

300

325

FR10

CPX30015AA

400

385

FR10

CPX40015AA

500

502

FR11

CPX50015AA

600

590

FR11

CPX60015AA

650

650

FR12

CPX65015AA

700

750

FR12

CPX70015AA

800

820

FR12

CPX80015AA

25

27

FR6

CPX02515DA

30

34

FR7

CPX03015DA

2

40

41

FR7

CPX04015DA

2

50

52

FR8

CPX05015DA

60

62

FR8

CPX06015DA

75

80

FR8

CPX07515DA

100

100

FR9

CPX10015DA

125

125

FR9

CPX12515DA

150

144

FR9

CPX15015DA

200

208

FR10

CPX20015DA
CPX25015DA

2

High Overload Drive

2

7

2

8

2
2

9

2
2

10

2

11

2
2

250

261

FR10

300

325

FR10

CPX30015DA

400

385

FR11

CPX40015DA

450

460

FR11

CPX45015DA

500

502

FR11

CPX50015DA
CPX60015DA

600

590

FR12

650

650

FR12

CPX65015DA

700

750

FR12

CPX70015DA

Notes
1 See enclosure dimensions beginning on Page V6-T2-258.
2 hp ratings are provided as a guideline. Drives should be sized per motor nameplate FLA.
3 The 18-pulse clean power assembly includes a standard drive, door-mounted local/remote keypad and enclosure.

2
2
2
2
2
V6-T2-246

Volume 6—Solid-State Motor Control CA08100007E—May 2014 www.eaton.com

Adjustable Frequency Drives
Low Harmonic Drives

Enclosed 18-Pulse
Drive

2.8

Enclosed 18-Pulse Base Drive NEMA 12 Filtered
Enclosure
Size 1

hp 2

Current
(A)

Chassis
Frame

Base Catalog
Number 3

2
2

Low Overload Drive
7

8

9

25

27

FR6

CPX02565AA

30

34

FR6

CPX03065AA

40

41

FR7

CPX04065AA

50

52

FR7

CPX05065AA

60

62

FR8

CPX06065AA

75

80

FR8

CPX07565AA

100

100

FR8

CPX10065AA

125

125

FR9

CPX12565AA

150

144

FR9

CPX15065AA

200

208

FR9

CPX20065AA

250

261

FR10

CPX25065AA

300

325

FR10

CPX30065AA

2
2
2
2
2
2
2
2

400

385

FR10

CPX40065AA

10

500

502

FR11

CPX50065AA

600

590

FR11

CPX60065AA

11

650

650

FR12

CPX65065AA

700

750

FR12

CPX70065AA

800

820

FR12

CPX80065AA

2

25

27

FR6

CPX02565DA

30

34

FR7

CPX03065DA

2

40

41

FR7

CPX04065DA

50

52

FR8

CPX05065DA

60

62

FR8

CPX06065DA

75

80

FR8

CPX07565DA

100

100

FR9

CPX10065DA

125

125

FR9

CPX12565DA

150

144

FR9

CPX15065DA

2
2

High Overload Drive
7

8

9

10

11

200

208

FR10

CPX20065DA

250

261

FR10

CPX25065DA

300

325

FR10

CPX30065DA

400

385

FR11

CPX40065DA

450

460

FR11

CPX45065DA

500

502

FR11

CPX50065DA

600

590

FR12

CPX60065DA

650

650

FR12

CPX65065DA

700

750

FR12

CPX70065DA

2
2
2
2
2
2
2
2
2
2

Notes
1 See enclosure dimensions beginning on Page V6-T2-258.
2 hp ratings are provided as a guideline. Drives should be sized per motor nameplate FLA.
3 The 18-pulse clean power assembly includes a standard drive, door-mounted local/remote keypad and enclosure.

2
2
2
2
2
2

Volume 6—Solid-State Motor Control CA08100007E—May 2014 www.eaton.com

V6-T2-247

2.8
2

Enclosed 18-Pulse
Drive

Adjustable Frequency Drives
Low Harmonic Drives

Enclosed 18-Pulse Base Drive Type 3R 1
Enclosure
Size 2

Current
(A)

Chassis
Frame

Base Catalog
Number 4

25

27

FR6

CPX02535AA

30

34

FR6

CPX03035AA

40

41

FR7

CPX04035AA

2

50

52

FR7

CPX05035AA

60

62

FR8

CPX06035AA

2

75

80

FR8

CPX07535AA

100

100

FR8

CPX10035AA

125

125

FR9

CPX12535AA

150

144

FR9

CPX15035AA

200

208

FR9

CPX20035AA

25

27

FR6

CPX02535DA

30

34

FR7

CPX03035DA

40

41

FR7

CPX04035DA

50

52

FR8

CPX05035DA

60

62

FR8

CPX06035DA

75

80

FR8

CPX07535DA

100

100

FR9

CPX10035DA

125

125

FR9

CPX12535DA

150

144

FR9

CPX15035DA

2

hp 3

Low Overload Drive

2

7

2

2

8

2

High Overload Drive

2

7

2
2
2
2

8

2

Notes
All Type 3R drives use the Size F enclosure.
2 See enclosure dimensions beginning on Page V6-T2-258.
3 hp ratings are provided as a guideline. Drives should be sized per motor nameplate FLA.
4 The 18-pulse clean power assembly includes a standard drive, door-mounted local/remote keypad and enclosure.

2

1

2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
V6-T2-248

Volume 6—Solid-State Motor Control CA08100007E—May 2014 www.eaton.com

2.8

Adjustable Frequency Drives
Low Harmonic Drives

Options

2

Enclosed 18-Pulse Drive Option Board Kits

2

The enclosed 18-pulse drives can accommodate a wide selection of expander and adapter option
boards to customize the drive for your application needs. The drive’s control unit is designed to accept
a total of five option boards (see figure below).

2

The enclosed 18-pulse drives factory-installed standard board configuration includes an A9 I/O board
and an A2 relay output board, which are installed in slots A and B.

2
2

9000X Series Option Board Kits
Option Boards

2

Option Board Kits

2

Field
Installed

Factory
Installed

SVX Ready Programs

Allowed Slot
Locations 2

Catalog
Number

Option
Designator

Basic

Local/
Remote

Standard

MSS

PID

Multi-P. PFC

2 RO (NC/NO)

B

OPTA2

—

■

■

■

■

■

■

■

6 DI, 1 DO, 2 AI, 1AO, 1 +10 Vdc ref,
2 ext +24 Vdc/ext +24 Vdc

A

OPTA9

—

■

■

■

■

■

■

■

6 DI

B, C, D, E

OPTB1

B1

—

—

—

—

—

■

■

1 RO (NC/NO), 1 RO (NO), 1 therm

B, C, D, E

OPTB2

B2

—

—

—

—

—

■

■

Option Kit Description 1
Standard I/O Cards
A

D E
B C

2
2
2
2

Extended I/O Cards

1 AI (mA isolated), 2 AO (mA isolated)

B, C, D, E

OPTB4

B4

■

■

■

■

■

■

■

3 RO (NO)

B, C, D, E

OPTB5

B5

—

—

—

—

—

■

■

3 Pt100 RTD board

B, C, D, E

OPTB8

B8

—

—

—

—

—

■

—

1 RO (NO), 5 DI 42–240 Vac input

B, C, D, E

OPTB9

B9

—

—

—

—

—

■

■

Modbus

D, E

OPTC2

C2

■

■

■

■

■

■

■

Modbus TCP

D, E

OPTCI

CI

■

■

■

■

■

■

■

Communication Cards 3

BACnet

D, E

OPTCJ

CJ

■

■

■

■

■

■

■

EtherNet/IP

D, E

OPTCQ

CQ

■

■

■

■

■

■

■

Johnson Controls N2

D, E

OPTC2

CA

■

■

■

■

■

■

■

PROFIBUS DP

D, E

OPTC3

C3

■

■

■

■

■

■

■

LonWorks

D, E

OPTC4

C4

■

■

■

■

■

■

■

PROFIBUS DP (D9 connector)

D, E

OPTC5

C5

■

■

■

■

■

■

■

CANopen (slave)

D, E

OPTC6

C6

■

■

■

■

■

■

■

DeviceNet

D, E

OPTC7

C7

■

■

■

■

■

■

■

Modbus (D9 type connector)

D, E

OPTC8

C8

■

■

■

■

■

■

■

RS-232 with D9 connection

D, E

OPTD3

D3

■

■

■

■

■

■

■

2
2
2
2
2
2
2
2
2
2
2
2

Notes
1 AI = Analog Input; AO = Analog Output, DI = Digital Input, DO = Digital Output, RO = Relay Output
2 Option card must be installed in one of the slots listed for that card. Slot indicated in bold is the preferred location.
3 OPTC2 is a multi-protocol option card.

2
2
2
2
2
2
2

Volume 6—Solid-State Motor Control CA08100007E—May 2014 www.eaton.com

V6-T2-249

2.8
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2

Adjustable Frequency Drives
Low Harmonic Drives

Modbus RTU Network
Communications
The Modbus Network Card
OPTC2 is used for connecting
the 9000X Drive as a slave
on a Modbus network. The
interface is connected by
a 9-pin DSUB connector
(female) and the baud rate
ranges from 300 to 19,200
baud. Other communication
parameters include an
address range from 1 to 247;
a parity of None, Odd or
Even; and the stop bit is 1.

DeviceNet Network
Communications
The DeviceNet Network Card
OPTC7 is used for connecting
the 9000X Drive on a
DeviceNet Network. It
includes a 5.08 mm pluggable
connector. Transfer method
is via CAN using a two-wire
twisted shielded cable with
two-wire bus power cable
and drain. The baud rates
used for communication
include 125K baud, 250K
baud and 500K baud.

PROFIBUS Network
Communications
The PROFIBUS Network Card
OPTC3 is used for connecting
the 9000X Drive as a slave
on a PROFIBUS-DP network.
The interface is connected
by a 9-pin DSUB connector
(female). The baud rates
range from 9.6K baud to 12M
baud, and the addresses
range from 1 to 127.

Johnson Controls Metasys N2
Network Communications
The OPTC2 fieldbus board
provides communication
between the 9000X Drive
and a Johnson Controls
Metasys™ N2 network.
With this connection, the
drive can be controlled,
monitored and programmed
from the Metasys system.
The N2 fieldbus is available as
a factory-installed option and
as a field-installable kit.

LonWorks Network
Communications
The LonWorks Network Card
OPTC4 is used for connecting
the 9000X Drive on a
LonWorks network. This
interface uses Standard
Network Variable Types
(SNVT) as data types. The
channel connection is
achieved using a FTT-10A
Free Topology transceiver
via a single twisted transfer
cable. The communication
speed with LonWorks is
78 kBits/s.
CANopen (Slave)
Communications
The CANopen (Slave)
Network Card OPTC6 is used
for connecting the 9000X
Drive to a host system.
According to ISO® 11898
standard cables to be chosen
for CAN bus should have
a nominal impedance of
120 ohms, and specific line
delay of nominal 5 nS/m.
120 ohm line termination
resistors required for
installation.

Modbus/TCP Network
Communications
The Modbus/TCP Network
Card OPTCI is used for
connecting the 9000X Drive
to Ethernet networks using
Modbus protocol. It includes
an RJ-45 pluggable
connector. This interface
provides a selection of
standard and custom register
values to communicate drive
parameters. The board
supports 10 Mbps and
100 Mbps communication
speeds. The IP address of
the board is configurable over
Ethernet using a supplied
software tool.

BACnet Network
Communications
The BACnet Network Card
OPTCJ is used for connecting
the 9000X Drive to BACnet
networks. It includes a 5.08
mm pluggable connector.
Data transfer is Master-Slave/
Token Passing (MS/TP)
RS-485. This interface uses
a collection of 30 Binary
Value Objects (BVOs) and
35 Analog Value Objects
(AVOs) to communicate
drive parameters. The card
supports 9.6, 19.2 and 38.4
Kbaud communication
speeds and supports network
addresses 1 to 127.
Ethernet/IP Network
Communications
The Ethernet/IP Network
Card OPTCK is used for
connecting the 9000X Drive
to Ethernet/Industrial Protocol
networks. It includes an RJ45 pluggable connector. The
interface uses CIP objects to
communicate drive
parameters (CIP is
“Common Industrial
Protocol,” the same protocol
used by DeviceNet). The
board supports 10 Mbps and
100 Mbps communication
speeds. The IP address of
the board is configurable
by Static, BOOTP and
DHCP methods.

2
2
2
V6-T2-250

Volume 6—Solid-State Motor Control CA08100007E—May 2014 www.eaton.com

Adjustable Frequency Drives
Low Harmonic Drives

2.8

Control/Communication Option Descriptions

2

For availability, see Product Selection for base drive voltage required.

2

Available Control/Communications Options
Option
Type

2

Option

Description

K1

Door-Mounted Speed Potentiometer—Provides the enclosed 18-pulse drive with the ability to adjust the frequency reference using a door-mounted potentiometer.
This option uses the 10 Vdc reference to generate a 0–10V signal at the analog voltage input signal terminal. When the HOA bypass option is added, the speed is
controlled when the HOA switch is in the HAND position. Without the HOA bypass option, a two-position switch (labeled local/remote) is provided on the keypad to select
speed reference from the speed potentiometer or a remote speed signal.

Control

K2

Door-Mounted Speed Potentiometer with HOA Selector Switch—Provides the enclosed 18-pulse drive with the ability to start/stop and adjust the speed
reference from door-mounted control devices or remotely from customer-supplied inputs. In HAND position, the drive will start and the speed is controlled by the doormounted speed potentiometer. The drive will be disabled in the OFF position. When AUTO is selected, the drive run and speed control commands are via user-supplied dry
contact and 4–20 mA signal.

Control

K3

3–15 psig Follower—Provides a pneumatic transducer that converts a 3–15 psig pneumatic signal to either 0–8 Vdc or a 1–9 Vdc signal interface with the enclosed
18-pulse drive. The circuit board is mounted on the inside of the front enclosure panel and connects to the user’s pneumatic control system via 6 ft (1.8m) of flexible
tubing and a 1/4 inch (6.4 mm) brass tube union.

Control

K4

HAND/OFF/AUTO Switch for Non-Bypass Configurations—Provides a three-position selector switch that allows the user to select either a HAND or AUTO mode
of operation. HAND mode is defaulted to keypad operation, and AUTO mode is defaulted to control from an external terminal source. These modes of operation can be
configured via drive programming to allow for alternate combinations of start and speed sources. Start and speed sources include Keypad, I/O and fieldbus.

Control

K5

MANUAL/AUTO Speed Reference Switch—Provides door-mounted selector switch for MANUAL/AUTO speed reference.

Control

K6

START/STOP Pushbuttons—Provide door-mounted START and STOP pushbuttons for either bypass or non-bypass configurations.

Control

KF

Bypass Test Switch for RB and RA—Allows the user to energize the AF drive for testing while operating the motor on the bypass controller. The Test Switch is
mounted on the inside of the enclosure door.

Addl. bypass

2

KO

Standard Elapsed Time Meter—Provides a door-mounted elapsed run-time meter.

Control

2

L1

Power On and Fault Power Lights—Provide a white Power On light that indicates power to the enclosed cabinet and a red fault light that indicates a drive fault
has occurred.

Light

2

L2

Bypass Pilot Lights for RB, RA Bypass Options—A green light indicates when the motor is running in Inverter mode and an amber light indicates when the motor is
running in Bypass mode. The lights are mounted on the enclosure door, above the switches.

Addl. bypass

2
2

2
2
2
2
2
2
2

LE

Red Run Pilot Light 0.87-Inch (22 mm)—Provides a red Run pilot light that indicates the drive is running.

Light

P1

Input Circuit Breaker—High interrupting circuit breaker that provides a means of short-circuit protection for the power cables between it and the enclosed 18-pulse
drive, and protection from high-level ground faults on the power cable. Allows a convenient means of disconnecting the enclosed 18-pulse drive from the line and the operating
mechanism can be padlocked in the OFF position. This is factory mounted in the enclosure. Standard rating is 65 kAIC at 208/480V. 100 kAIC is available as an option.

Input

PE

Output Contactor—Provides a means for positive disconnection of the drive output from the motor terminals. The contactor coil is controlled by the drive’s run or
permissive logic. NC and NO auxiliary contacts rated at 10A, 600 Vac are provided for customer use. Bypass options RB and RA include an output contactor as standard.
This option includes a low VA 115 Vac fused control power transformer and is factory mounted in the enclosure.

Output

PF

Output Filter—Used to reduce the transient voltage (DV/DT) at the motor terminals. The output filter is recommended for cable lengths exceeding 100 ft (30.5m) with a
drive of 3 hp and above, for cable lengths of 33 ft (10.1m) with a drive of 2 hp and below, or for a drive rated at 525–690V. This option is mounted in the enclosure.

Output

2

PG

MotoRx (300–600 Ft) 1000 V/μS DV/DT Filter—Used to reduce transient voltage (DV/DT) and peak voltages at the motor terminals. This option is comprised of a 0.5%
line reactor, followed by capacitive filtering and an energy recovery/clamping circuit. Unlike the output filter (see option PF), the MotoRx recovers most of the energy from the
voltage peaks, resulting in a lower voltage drop to the motor, and therefore conserving power. This option is used when the distance between a single motor and the drive
is 300–600 ft (91.4–182.9m).

Output

2

PH

Single Overload Relay—Uses a bimetallic overload relay to provide additional overload current protection to the motor on configurations without bypass options.
It is included with the bypass configurations for overload current protection in the bypass mode. The overload relay is mounted within the enclosure, and is manually
resettable. Heater pack included.

Output

PI

Dual Overload Relays—This option is recommended when a single drive is operating two motors and overload current protection is needed for each of the motors.
The standard configuration includes two bimetallic overload relays, each sized to protect a motor with 50% of the drive hp rating. For example, a 100 hp drive would
include two overload relays sized to protect two 50 hp motors. The relays are mounted within the enclosure, and are manually resettable. Heater packs not included.

Output

PN

Dual Overloads for Bypass—This option is recommended when a single drive is operating two motors in the Bypass mode and overload current protection is needed
for each of the motors. The standard configuration includes two bimetallic overload relays, each sized to protect a motor with 50% of the drive hp rating. For example,
a 100 hp drive would include two overload relays sized to protect two 50 hp motors. The relays are mounted within the enclosure, and are manually resettable.

Addl. bypass

2
2

2
2
2
2
2
2
2
2
2
2
2

Volume 6—Solid-State Motor Control CA08100007E—May 2014 www.eaton.com

V6-T2-251

2.8

Adjustable Frequency Drives
Low Harmonic Drives

2

For availability, see Product Selection for base drive voltage required.

2

Available Control/Communications Options, continued

2

Option

Description

RA

Manual HOA Bypass Controller—The manual HAND/OFF/AUTO (HOA)—three-contactor—bypass option provides a means of bypassing the enclosed 18-pulse drive,
allowing the AC motor to be operated at full speed directly from the AC supply line. This option consists of an input HMCP, a fused control power transformer, and a
full voltage bypass starter with a door-mounted HOA selector switch and an INVERTER/BYPASS switch. The HOA switch provides the ability to start and stop the drive
in the inverter mode. IEC type input, bypass and input contactors are provided. The contactors are mechanically and electrically interlocked (see wiring diagram on
Page V6-T2-257).

Bypass

RB

Manual IOB Bypass Controller—The manual INVERTER/OFF/BYPASS (IOB)—three-contactor—bypass option provides a means of bypassing the enclosed 18-pulse
drive, allowing the AC motor to be operated at full speed directly from the AC supply line. This option consists of an input HMCP, a fused control power transformer, and
a full voltage bypass starter with a door-mounted IOB selector switch. IEC type input, bypass and input contactors are provided. The contactors are mechanically and
electrically interlocked (see wiring diagram on Page V6-T2-257).

Bypass

RC

Auto Transfer HOA Bypass Controller —The manual HAND/OFF/AUTO (HOA)—three-contactor—bypass option provides a means of bypassing the enclosed
18-pulse drive, allowing the AC motor to be operated at full speed directly from the AC supply line. The circuitry provides an automatic transfer of the load to “across the
line” operation after a drive trip. This option consists of an input HMCP, a fused control power transformer, and a full voltage bypass starter with a door-mounted HOA
selector switch and an INVERTER/BYPASS switch. The HOA switch provides the ability to start and stop the drive in either mode. IEC type input, bypass and input
contactors are provided. The contactors are mechanically and electrically interlocked (see wiring diagram on Page V6-T2-257). Door-mounted pilot lights are provided
that indicate bypass or inverter operation. A green light indicates when the motor is running in inverter mode and an amber light indicates when the motor is running in
bypass mode.
WARNING: The motor may restart when the overcurrent relay is reset when operating in bypass, unless the IOB selector switch is turned to the OFF position.

Bypass

RD

Bypass

2

Auto Transfer IOB Bypass Controller—The auto INVERTER/OFF/BYPASS (IOB)—three-contactor—bypass option provides a means of bypassing the enclosed
18-pulse drive, allowing the AC motor to be operated at full speed directly from the AC supply line. The circuitry provides an automatic transfer of the load to “across the
line” operation after a drive trip. This option consists of an input HMCP, a fused control power transformer, and a full voltage bypass starter with a door-mounted IOB
selector switch. IEC type input, bypass and input contactors are provided. The contactors are mechanically and electrically interlocked (see wiring diagram on Page
V6-T2-257). Door-mounted pilot lights are provided that indicate bypass or inverter operation. A green light indicates when the motor is running in inverter mode and an
amber light indicates when the motor is running in bypass mode.
WARNING: The motor may restart when the overcurrent relay is reset when operating in bypass, unless the IOB selector switch is turned to the OFF position.

RG

Reduced Voltage Starter for Bypass—Used in conjunction with bypass option RA, RB, RC or RD. This option adds reduced voltage soft starter to bypass assembly for
soft starting in bypass mode.

Bypass

2

S7

10.00-Inch (254.0 mm) Expansion—Expansion cabinet allows for special components, customer-supplied components or oversized cables.
NOTE: Enclosure expansion rated Type 1 only.

Enclosure

2

S8

20.00-Inch (508.0 mm) Expansion—Expansion cabinet allows for special components, customer-supplied components or oversized cables.
NOTE: Enclosure expansion rated Type 1 only.

Enclosure

2

S9

Space Heater—Prevents condensation from forming in the enclosure when the drive is inactive or in storage. Includes a thermostat for variable temperature control.
The heater requires a customer-supplied 115V remote supply source.

Enclosure

2
2
2
2
2
2
2
2
2

Option
Type

2
2

Dissipated Watt Losses
Horsepower

40

50

60

75

100

125

150

200

250

300

350

400

450

500

600

700

800

2

Watts

1844

2170

2540

3040

4011

4940

5730

8020

9383

11600

13600

15700

16250

17976

20393

27200

31400

2

Conformal (Varnished) Coating 1

480V Input Disconnect Selection 2
Delivery
Code

Horsepower

P1 Input
Breaker

Bypass Motor Circuit Protector
(RA, RB, RC, RD)

FR9

FP

25

HFD3050

HMCP050K2C

FR10

FP

30

HFD3060

HMCP100R3C

FP

FR11

FP

40

HFD3080

HMCP100R3C

—

FR12

FP

2

Chassis
Frame

Delivery
Code

Chassis
Frame

2

FR6

FP

FR7

FP

2

FR8
—

50

HFD3100

HMCP100R3C

2

60

HFD3100

HMCP150T4C

2

75

HFD3125

HMCP150T4C

100

HFD3150

HMCP150U4C

125

HFD3200

HMCP250W5C

150

HFD3225

HMCP250W5C

200

HKD3300

HMCP400X5C

250

HKD3400

HMCP400X5C

300–400

HLD3600

HMCP600L6W

500–600

HND3800

HMCP800X7W

650–800

HND312

3

2
2
2
2
2

Notes
1 See catalog number description to order.
2 Contact factory for 208V and 575V applications.
3 Contact factory.

V6-T2-252

Volume 6—Solid-State Motor Control CA08100007E—May 2014 www.eaton.com

2.8

Adjustable Frequency Drives
Low Harmonic Drives

Enclosed Drive Options

2

Light Options

Meter Options

Description

Catalog
Number Suffix

Description

Catalog
Number Suffix

Power on, run, fault LED lights (22 mm)

L1

Standard elapsed time meter

KO

Power on, fault LED lights (22 mm)

L3

Frequency meter

KS

Green LED run light (22 mm)

LA

MP-3000 relay with URTD

KV

Green LED stop light (22 mm)

LD

MP-3000 relay with URTD and CTs

KU

Red LED run light (22 mm)

LE

Red LED stop light (22 mm)

LF

Red LED fault light (22 mm)

LG

Power on white LED light (22 mm)

LJ

Miscellaneous LED light (22 mm)

LU

Control Options

2
2
2
2

Enclosure Options
Enclosure
Size

2

Catalog
Number Suffix

10.00 Inch (254.0 mm) Expansion
7

S7

8

S7

2
2
2
2

Catalog
Number Suffix

9

S7

Description

10

S7

Door-mounted speed potentiometer

K1

11

S7

Door-mounted speed potentiometer with HOA selector switch

K2

20.00 Inch (508.0 mm) Expansion

3–15 psig follower

K3

7

S8

HOA selector switch

K4

8

S8

MANUAL/AUTO reference switch

K5

9

S8

START-STOP pushbuttons

K6

10

S8

Type D2 control relay

SD

11

S8

On-delay relay

SE

Space Heater 1

Off-delay relay

SF

7

S9

Additional terminal blocks per 4 points

SD

8

S9

9

S9

10

S9

11

S9

2

7

SN

2

8

SN

9

SN

10

SN

11

SN

Bypass Control Options
Description

Catalog
Number Suffix

Bypass test switch used with RA and RB

KF

Inverter/bypass pilot lights

L2

2
2
2
2
2
2
2

Plastic Nameplate

2
2
2

Note
1 Requires customer-supplied 115 Vac supply.

2
2
2
2
2
2
2
2

Volume 6—Solid-State Motor Control CA08100007E—May 2014 www.eaton.com

V6-T2-253

2.8

Adjustable Frequency Drives
Low Harmonic Drives

2

208V and 230V Power Options, 25–200 hp

2

208V and 230V Bypass Options, 25–200 hp

Description

Catalog
Number Suffix

Description

Catalog
Number Suffix

Input breaker

P1

Manual HOA bypass controller

RA

2

Output contactor

PE

IOB bypass controller

RB

2

Single overload relay

PH

Auto transfer HOA bypass controller

RC

Dual overload relays

PI

Auto transfer IOB bypass controller

RD

2

MOV

P7

Reduced voltage starter for bypass

RG

50 kA surge protective device

P8

Dual overloads for bypass

PN

2

100 kA surge protective device

P9

2

480 and 575V Power Options, 25–800 hp

2

Description

Catalog
Number Suffix

Input breaker

P1

2

Output contactor

2

Output filter

480 and 575V Bypass Options, 25–800 hp
Description

Catalog
Number Suffix

Manual HOA bypass controller

RA

IOB bypass controller

RB

PE

Auto transfer HOA bypass controller

RC

PF

Auto transfer IOB bypass controller

RD

MotoRx (300–600 Ft) DV/DT filter

PG

Reduced voltage starter for bypass

RG

2

Single overload relay

PH

Dual overloads for bypass

PN

Dual overload relays

PI

2

Input MOV

P7

2

50 kA surge protective device

P8

100 kA surge protective device

P8

2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
V6-T2-254

Volume 6—Solid-State Motor Control CA08100007E—May 2014 www.eaton.com

Adjustable Frequency Drives
Low Harmonic Drives

2.8

Technical Data and Specifications

2

Enclosed 18-Pulse Drives
Description

Specification

Description

2

Specification

2

Input/Output Interface Features

Primary Design Features

Setup adjustment provisions

45–66 Hz input frequency

Standard

Output: AC volts maximum

Input voltage base

Remote keypad/display

Standard

Output frequency range

0–320 Hz

Personal computer

Standard

Initial output current (IH)

250% for 2 seconds

2
2

2

Operator control provisions

Overload (1 minute [IH/IL])

150%/110%

Drive mounted keypad/display

Standard

Enclosure space heater

Optional

Remote keypad/display

Standard

Oversize enclosure

Standard

Conventional control elements

Standard

Output contactor

Optional

Serial communications

Optional

Bypass motor starter

Optional

115 Vac control circuit

Optional

2

Listings

UL, cUL, 508C

Standard

2

Protection Features

2

Speed setting inputs
Keypad

2

Incoming line fuses

Standard 200 kAIC rating

0–10 Vdc potentiometer/voltage signal

Standard

AC input circuit disconnect

Optional

4–20 mA isolated

Configurable

Phase rotation insensitive

Standard

4–20 mA differential

Configurable

EMI filter

Standard FR6 thru FR9 1

3–15 psig

Optional

Input phase loss protection

Standard

2
2

2

Analog outputs

Input overvoltage protection

Standard

Speed/frequency

Standard

Line surge protection

Standard

Torque/load/current

Programmable

Output short-circuit protection

Standard

Motor voltage

Programmable

Output ground fault protection

Standard

Kilowatts

Programmable

Output phase protection

Standard

0–10 Vdc signals

Configurable w/jumpers

Overtemperature protection

Standard

4–20 mA DC signals

Standard

DC overvoltage protection

Standard

Isolated signals

Standard

Drive overload protection

Standard

Discrete outputs

Motor overload protection

Standard

Fault alarm

Programmer software

Optional

Drive running

Standard

Local/remote keypad

Standard

Drive at set speed

Programmable

Keypad lockout

Standard

Optional parameters

14

Fault alarm output

Standard

Dry contacts

2 Form C contacts available

Built-in diagnostics

Standard

Additional discrete outputs

Optional

Surge protective device

Optional

2
2
2
2

Standard

2
2
2
2

Communications
RS-232

Standard

RS-422/485

Optional

DeviceNet™

Optional

Modbus RTU

Optional

CANopen (slave)

Optional

PROFIBUS-DP

Optional

LonWorks

Optional

Johnson Controls Metasys N2

Optional

EtherNet/IP/Modbus TCP

Optional

BACnet

Optional

2
2
2
2
2
2

Note
1 The EMI filter is optional in FR10 and larger.

2
2
2

Volume 6—Solid-State Motor Control CA08100007E—May 2014 www.eaton.com

V6-T2-255

2.8
2

Adjustable Frequency Drives
Low Harmonic Drives

Enclosed 18-Pulse Drives
Description

Standard I/O Specifications
Specification

2

Performance Features

2

Sensorless vector control

Standard

Volts/hertz control

Standard

2

IR and slip compensation

Standard

Electronic reversing

Standard

2

Dynamic braking

Optional

DC braking

Standard

PID set point controller

Programmable

2

Critical speed lockout

Standard

Current (torque) limit

Standard

2

Adjustable acceleration/deceleration

Standard

Linear or S curve accel/decel

Standard

2

2
2

Jog at preset speed

Standard

Thread/preset speeds

7

Voltage: 0–±10V, Ri >200 kohms
Current: 0 (4)–20 mA, Ri = 250 ohms

Two–digital output programmable

Form C relays 250 Vac
30 Vdc 2 amp resistive

One–analog output programmable
configurable w/jumper

0–20 mA, RL max. 500 ohms 10 bits ±2%

I/O Specifications for Control/Communication Options
Description

Specification

Analog voltage, input

0–±10V, Ri >200 kilohms

Analog current, input

0 (4)–20 mA, Ri = 250 ohms

Digital input

24V: “0” <10V, “1” >18V, Ri >5 kilohms

Auxiliary voltage

24V (±20%), max. 50 mA

Analog voltage, output

0 (2)–10V, RL >1 kilohm, resolution
10 bit, accuracy <±2%

Relay output max. switching voltage

300 Vdc, 250 Vac

Standard Conditions for Application and Service

Relay output max. switching load

3A/24 Vdc, 300 Vdc, 250 Vac 1

Maximum operating ambient temperature 0–50°C up to FR9
0–40°C FR10 and larger, consult factory for 50°C
rating above FR9

Relay output max. continuous load

2A rms

Thermistor input

Rtrip = 4.7 kohms

Storage temperature

–40 to 60°C

Humidity (maximum), noncondensing

95%

Note
1 For applications above 3A consult instruction manual.

Altitude (maximum without derate)

3300 ft (1000m)

Standard

2

Optional

Carrier frequency adjustment

1–16 kHz

Standard

2

Line voltage variation

+10/–15%

Line frequency variation

45–66 Hz

2

Efficiency

>95%

Power factor (displacement)

0.99+

Power factor (apparent)

0.99

2

Two–analog input configurable
w/jumpers

10V ±3%, max. 10 mA

Elapsed time meter

2

24V: “0” <10V, “1” >18V,Ri >5 kohms

0 (4)–20 mA, RL = 500 kilohms, resolution
10 bit, accuracy <±2%

Selectable

Coast or ramp stop selection

2

Six–digital input programmable

Analog current, output

Automatic restart
Coasting motor start

2

Specification

Reference voltage

2
2

Description

2
2
2
2
2
2
2
2
2
2
2
V6-T2-256

Volume 6—Solid-State Motor Control CA08100007E—May 2014 www.eaton.com

2.8

Adjustable Frequency Drives
Low Harmonic Drives

Wiring Diagrams
Power Diagram Up to FR9

2

2
Inverter Input
I
Contactor

Inverter Input
Contactor

I

2

HMCP

Circuit
Breaker
Input
Fusing

2

Power Diagram Up to FR9 with Bypass

18-Pulse
Transformer

2

Input
Fusing

2
2

18-Pulse
Transformer

18-Pulse
Diode Bridge

Optional
Reduced
Voltage Starter

18-Pulse
Diode Bridge

9000X
Drive

2

(IT.)

2
2

9000X
Drive

2

Mechanical
Interlock
Output M
Contactor

L

Bypass
Contactor

2

Motor

2

Overload

2

Motor

Power Diagram FR10 and Larger

2
2

Power Diagram FR10 and Larger with Bypass

2

HMCP

Circuit
Breaker

2
Inverter Input
I
Contactor

Input
Fusing

2

Input
Fusing

18-Pulse
Transformer
Pre-charge
Complete
Contactor

2

(IT.)

2

Pre-charge
Complete
Contactor

6-Pulse
Diode Bridge
9000X
12-Pulse Drive

Optional
Reduced
Voltage Starter

18-Pulse
Transformer

2
2

6-Pulse
Diode Bridge

2

9000X
12-Pulse Drive

2

Mechanical
Interlock
Output M
Contactor

L

2

Bypass
Contactor

2

Motor

2

Overload

2

Motor

2
Volume 6—Solid-State Motor Control CA08100007E—May 2014 www.eaton.com

V6-T2-257

2.8
2

Adjustable Frequency Drives
Low Harmonic Drives

Dimensions
Approximate Dimensions in Inches (mm)

2

Enclosure Size 7

2

25–150 hp IL and 25–125 hp IH 480V—25–100 hp IL and 25–75 hp IH 575V

2

4.79
(121.7)

Exhaust Air

2

20.00
(508.0)

For
Cable
Entry

2
26.25
(666.8)

2

Hinged
Side Door
Clearance at 90º

2

10.00
(254.0)

15.00
(381.0)

2.00
(50.8)

Top View

2

4.00 (101.6) Minimum
Free Air Space Required

2
2
2

Keypad
Flanged Disconnect Supplied
With Circuit Breaker
When Specified

2
2

Operator Elements
When Specified, Mounted
On These Panels

2
2
2

84.37
(2143.0)

Door Handle
(key-lock optional)

93.92
(2385.6)

90.00
(2286.0)

2
2
2
2

Quarter Turn Latch
(three places)

2
2

15.50
(393.7)

2

21.50
(546.1)

2

18.75
(476.3)

2
2

30.00
(762.0)
Opening For Bottom
Cable Entry
14.90
(378.5)

Side View

2
2

ø0.56 (ø14.2) Dia.
Mounting Holes
(five places)

4.25
(107.9)

7.00
(177.8)

5.75
(146.1)
Finish: Enclosure—ANSI 61 Gray (light)
Material: Enclosure and Backplate—
12 ga. = 0.1046 Cold Rolled Steel

1.75
(44.5)

10.50
(266.7)

24.45
(621.0)

28.05
(712.5)

Bottom View

2
V6-T2-258

Volume 6—Solid-State Motor Control CA08100007E—May 2014 www.eaton.com

2.8

Adjustable Frequency Drives
Low Harmonic Drives

Approximate Dimensions in Inches (mm)

2

Enclosure Size 8

2

200–250 hp IL and 150–200 hp IH 480V—125–200 hp IL and 100–150 hp IH 575V
1.25
(31.8)

2

31.00
(787.4)

2

8.25
(209.6)

2
2
2

For Top
Cable Entry
(two places)

2

Top View

2

4.00 (101.6) Minimum
Free Air Space Required

2
2
2
2
Drive
Circuit Breaker

2
2

90.00
(2286.0)

2

93.50
(2374.9)

84.37
(2143.0)

2
Door Handle
(key-lock optional)

2
2
2
2
2

21.45
(544.8)

24.00
(609.6)
Side View

48.00
(1219.2)

For Bottom
Cable Entry
9.50
(241.3)
22.47
(570.7)

Finish: Enclosure—ANSI 61 Gray (light)
Material: Enclosure and Backplate—
12 ga. = 0.1046 Cold Rolled Steel

2

21.31
(541.3)

13.97
(354.8)

32.20
(817.9)
7.73
5.48
(196.3) (139.2)
3.01 (76.5)
37.47 (951.7)
45.22 (1148.6)
Bottom View

2
2

12.50
(317.5)

2

ø0.56
(ø14.2)
(five places)

Volume 6—Solid-State Motor Control CA08100007E—May 2014 www.eaton.com

2

2
2
2
V6-T2-259

2.8
2
2
2

Adjustable Frequency Drives
Low Harmonic Drives

Approximate Dimensions in Inches (mm)

Enclosure Size 9
300–400 hp IL and 250–350 hp IH 480V—250–400 hp IL and 200–300 hp IH 575V
43.50 (1104.9)

1.50 (38.1)

2

8.75
(222.3)

2

7.46 x 15.00
(189.5 x 381.0)
Access in Top
(two places)

2
2

90 Max.
Door
Opening

2

27.36
(694.9)

2

29.05
(737.9)

2

90 Max.
Door
Opening

27.06
(687.3)

Top View

2

4.00 (101.6) Minimum
Free Air Space Required

2
2
2
2
2
2
2
2

93.50
(2374.9)

Drive
Circuit Breaker

90.00
(2286.0)
Door Handle
(key-lock optional)

2
2

Access
Plate
(4 places)

2
2

8.50 x 12.00 (215.9 x 304.8)
Bottom Access

ø0.56 (ø14.2) Dia.
Mounting Hole
(five places)

2
2

32.72 (831.1)

Side View

2
2

60.00 (1524.0)
Front View

24.00 (609.6)
25.14 (638.6)

2

25.00
(635.0)

Finish: Enclosure—ANSI 61 Gray (light)
Material: Enclosure and Backplate—
12 ga. = 0.1046 Cold Rolled Steel

18.84
(478.5)
8.20
(208.3)
2.00 (50.8)

2
2
V6-T2-260

11.93
(303.0)
22.90 (581.7)
46.30 (1176.0)
54.90 (1394.5)
Bottom View

Volume 6—Solid-State Motor Control CA08100007E—May 2014 www.eaton.com

2.8

Adjustable Frequency Drives
Low Harmonic Drives

Approximate Dimensions in Inches (mm)

2

Enclosure Size 10

2

500–600 hp IL and 400–500 hp IH 480V—500–600 hp IL and 400–500 hp IH 575V

2

15.63
(397.0)

2

9.03
(229.4)

2
2

21.00 x 10.00
(533.4 x 254.0)
Access in Top

2
2

Top View

2

4.00 (101.6) Minimum
Free Air Space Required
Flanged
Disconnect
Supplied with
Circuit Breaker
When Specified

2
2

Keypad
Door Handle
(key-lock optional)

Operator
Elements
When
Specified,
Mounted
on These
Panels

93.50
(2374.9)

2

2
2
2
2

90.00
(2286.0)

2

84.37
(2143.0)

Quarter-Turn
Latch (four places)

2
2

Intake Ventilating
Slots (filtered on
Type 12)

35.75 (908.1)
30.50 (774.7)
31.75 (806.5)

2

21.00 x 10.00 (533.4 x 254.0)
Bottom Access

15.64
(397.3)

2
2

35.75 (908.1)
80.00 (2032.0)
Front View

Side View

2

2
2

29.04
(737.6)

2

17.79
(451.9)

4.87
(123.7)

2
2

2.00 (50.8)
Finish: Enclosure – ANSI 61 Gray (light)
Material: Enclosure and Backplate—
12 ga. = 0.1046 Cold Rolled Steel

38.00 (965.2)
42.02 (1067.3)

2
78.02 (1981.7)
Bottom View

Volume 6—Solid-State Motor Control CA08100007E—May 2014 www.eaton.com

2
V6-T2-261

2.8
2
2
2

Adjustable Frequency Drives
Low Harmonic Drives

Approximate Dimensions in Inches (mm)

Enclosure Size F Type 3R Drives
25–250 hp IL and 25–200 hp IH 480V—25–200 hp IL and 25–150 hp IH 575V Type 3R Drives
60.00 (1524.0)

2

18.00 x 8.50
(457.2 x 215.9)
Side Access

Exhaust Air
Venting Slots

2

Enclosure
Door Stop

2
2

Flanged
Disconnect
Supplied with
Circuit Breaker
When Specified
Key Locking
Three-Position
Latch
93.50
Filtered
(2374.9)
Intake Air
Ventilating
Slots

Keypad Located
Inside Locking
Enclosure Door

2

Operator Elements
When Specified,
Mounted Inside
Locking Enclosure Door

2
2
2
2

18.00 x 8.50
(457.2 x 215.9)
Bottom Access

2

29.32
(744.7)

2

9.08
(230.5)

2

6.82
(173.3)

2
2

25.84
(656.2)
29.58
(751.2)

35.75 (908.0)
48.00 (1219.2)

2

2

37.50 (952.5)

3.11 (78.9)
37.43 (950.7)
45.32 (1151.1)

Enclosed 18-Pulse Drive Enclosure Dimensions
Enclosure
Size 1

Width

Height

Depth

Approx. Shipping
Weight in Lbs (kg)

7

30.00 (762.0)

90.00 (2286.0)

21.50 (546.1)

1000 (454)

2

8

48.00 (1219.2)

90.00 (2286.0)

26.14 (664.0)

1400 (636)

9

60.00 (1524.0)

90.00 (2286.0)

25.74 (653.8)

1800 (817)

2

10

80.00 (2032.0)

90.00 (2286.0)

31.75 (806.5)

2100 (953)

11 23

120.00 (3048.0)

90.00 (2286.0)

25.74 (653.8)

2500 (1,135)

F4

60.00 (1524.0)

93.50 (2374.9)

37.50 (952.5)

2500 (1,135)

2

2
2
2
2

Notes
1 Enclosure sizes accommodate drive and options, including bypass and disconnect.
For other power options, consult your Eaton representative.
2 Consult factory. Limited power options available.
3 Enclosure size 11 consists of two of the enclosure size 9.
4 All Type 3R drives use the Size F enclosure.

2
2
2
2
V6-T2-262

Volume 6—Solid-State Motor Control CA08100007E—May 2014 www.eaton.com

Exhaust Air
Venting Slots

Adjustable Frequency Drives
LCX9000 Liquid Cooled Drives

2.9

Contents

LCX9000 Liquid Cooled Adjustable Frequency Drives

Description

Page

LCX9000 Drives
Catalog Number Selection . . . . . . . . . . . . . . . .
Product Selection . . . . . . . . . . . . . . . . . . . . . . .
Options . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Technical Data and Specifications . . . . . . . . . .
Wiring Diagrams . . . . . . . . . . . . . . . . . . . . . . . .
Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . .

V6-T2-264
V6-T2-265
V6-T2-268
V6-T2-270
V6-T2-271
V6-T2-273

2
2
2
2
2
2
2
2
2
2

Product Description

Features and Benefits

The LCX9000 Liquid Cooled
Drive family continues
Eaton’s tradition of providing
state-of-the-industry
products, by taking advantage
of liquid cooling technology in
lieu of air-cooling techniques.

●

●

The LCX9000 drives are
liquid-cooled products that
utilize potable water or a
water-glycol mixture as a
cooling medium.
●

Compact size and low
heat transfer rates allow
enclosure size to be greatly
reduced, which is especially
beneficial in UL Type 4X
applications
Design is modular, with
control and power modules
independent of each other.
Connection between
power and control modules
can be direct or extended
via a fiber optic cable
Same reliable control
module and operating
system as the SPX9000
air-cooled drives

2

Standards and
Certifications
●

●

●

●

CE mark ensures
compliance with the
Electromagnetic
Compatibility Directive
(EMC) and the Low Voltage
Directive (LVD)
Reliable drive with over
500,000 hours MTBF
based on MIL 217
Currently supports
DeviceNet, PROFIBUS-DP,
Modbus RTU and Modbus
TCP communication
protocols
Separately mounted line
reactor included with AC
fed models

●

2

CE

2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2

Volume 6—Solid-State Motor Control CA08100007E—May 2014 www.eaton.com

V6-T2-263

2.9
2
2

Adjustable Frequency Drives
LCX9000 Liquid Cooled Drives

Catalog Number Selection
LCX9000 Liquid Cooled Adjustable Frequency Drives

LCX 016 A 0 – 4 A 3 B 2

2
2

Product Family
LCX = High performance, liquid-cooled drive

2
2
2
2
2
2
2
2
2
2
2

Current Rating
480V
016 = 16A
385 = 385A
022 = 22A
460 = 460A
031 = 31A
520 = 520A
038 = 38A
590 = 590A
045 = 45A
650 = 650A
061 = 61A
730 = 730A
072 = 72A
820 = 820A
087 = 87A
920 = 920A
105 = 105A
H10 = 1030A
140 = 140A
H11 = 1150A
168 = 168A
H13 = 1370A
205 = 205A
H16 = 1640A
261 = 261A
H20 = 2060A
300 = 300A
H23 = 2300A
690V
170 = 170A
590 = 590A
208 = 208A
650 = 650A
261 = 261A
750 = 750A
325 = 325A
820 = 820A
385 = 385A
H10 = 1030A
416 = 416A
H11 = 1180A
460 = 460A
H13 = 1300A
502 = 502A
H15 = 1500A

Software Series
A = Standard

Enclosure Rating
0 = Open chassis

2

Voltage Rating
4 = 380–500V
5 = 520–690V

Keypad
A = Alphanumeric

Input Options
3 = Three-phase, EMC T
7 = DC Input

2
2

_ _

_ _

Options
List options in alphabetical order.
Extended I/O Card Options
A3 = 2 RO, therm
A4 = Encoder low volt +5V/15V/24V
A5 = Encoder high volt +15V/24V
A7 = Dual encoder +15V/24V
A8 = 6 DI, 1 DO, 2 AI, 1AO
AE = Encoder with 2 DOs
B1 = 6 DI, 1 ext +24 Vdc/EXT +24 Vdc
B2 = 1 RO (NC-NO), 1 RO (NO), 1 therm
B4 = 1 AI (mA isolated), 2 AO (mA isolated),
1 ext +24 Vdc/EXT + 24 Vdc
B5 = 3 RO (NO)
B8 = 1 ext +24 Vdc/EXT +24 Vdc, 3 Pt100
B9 = 1 RO (NO), 5 DI 42–240 Vac input
BB = SPI, absolute encoder
Communication Cards
CA = Johnson Controls N2
CI = Modbus TCP
C2 = Modbus
C3 = PROFIBUS DP
C4 = LonWorks
C5 = PROFIBUS DP (D9 Connector)
C6 = CANopen (Slave)
C7 = DeviceNet
C8 = Modbus (D9 Type Connector)
D1 = Adapter
D2 = Adapter
D3 = RS-232 with D9 Connection

Board Modifications
2 = Varnished boards

Brake Chopper Options 1
N = No brake chopper circuit
B = Internal brake chopper

2
2

_ _

Note
1 Brake chopper is only available in 480V CH3 drives.

2
2
2
2
2
2
2
2
2
2
V6-T2-264

Volume 6—Solid-State Motor Control CA08100007E—May 2014 www.eaton.com

Adjustable Frequency Drives
LCX9000 Liquid Cooled Drives

2.9

Product Selection
LCX9000 Liquid Cooled
Drives

2
2

380–500 Vac Liquid Cooled Drives

2

Motor Output
Current
Thermal, Ith (A)

IL (A)

IH (A)

kW

Chassis

Catalog Number

16

15

11

7.5

CH3

LCX016A0-4A3N2

22

20

15

11

CH3

LCX022A0-4A3N2

31

28

21

15

CH3

LCX031A0-4A3N2

38

35

25

18.5

CH3

LCX038A0-4A3N2

45

41

30

22

CH3

LCX045A0-4A3N2

61

55

41

30

CH3

LCX061A0-4A3N2

72

65

48

37

CH4

LCX072A0-4A3N2

87

79

58

45

CH4

LCX087A0-4A3N2

105

95

70

55

CH4

LCX105A0-4A3N2

140

127

93

75

CH4

LCX140A0-4A3N2

168

153

112

90

CH5

LCX168A0-4A3N2

205

186

137

110

CH5

LCX205A0-4A3N2

261

237

174

132

CH5

LCX261A0-4A3N2

300

273

200

160

CH61

LCX300A0-4A3N2

385

350

257

200

CH61

LCX385A0-4A3N2

460

418

307

250

CH72

LCX460A0-4A3N2

520

473

347

250

CH72

LCX520A0-4A3N2

590

536

393

315

CH72

LCX590A0-4A3N2

650

591

433

355

CH72

LCX650A0-4A3N2

730

664

487

400

CH72

LCX730A0-4A3N2

820

745

547

450

CH63

LCX820A0-4A3N2

920

836

613

500

CH63

LCX920A0-4A3N2

1030

936

687

560

CH63

LCXH10A0-4A3N2

1150

1045

766

600

CH63

LCXH11A0-4A3N2

1370

1245

913

700

CH74

LCXH13A0-4A3N2

1640

1491

1093

900

CH74

LCXH16A0-4A3N2

2060

1873

1373

1100

CH74

LCXH20A0-4A3N2

2300

2091

1533

1200

CH74

LCXH23A0-4A3N2

2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2

Volume 6—Solid-State Motor Control CA08100007E—May 2014 www.eaton.com

V6-T2-265

2.9
2

LCX9000 Liquid Cooled
Drives

2

Adjustable Frequency Drives
LCX9000 Liquid Cooled Drives

525–690 Vac Liquid Cooled Drives
Motor Output
Current
Thermal, Ith (A)

IL (A)

IH (A)

kW

Chassis

Catalog Number

2

170

155

113

110

CH61

LCX170A0-5A3N2

2

208

189

139

132

CH61

LCX208A0-5A3N2

261

237

174

160

CH72

LCX261A0-5A3N2

2

325

295

217

200

CH72

LCX325A0-5A3N2

385

350

257

250

CH72

LCX385A0-5A3N2

2

416

378

277

250

CH72

LCX416A0-5A3N2

460

418

307

300

CH72

LCX460A0-5A3N2

2

502

456

335

355

CH72

LCX502A0-5A3N2

2

590

536

393

400

CH63

LCX590A0-5A3N2

650

591

433

450

CH63

LCX650A0-5A3N2

2

750

682

500

500

CH63

LCX750A0-5A3N2

820

745

547

560

CH74

LCX820A0-5A3N2

2

920

836

613

650

CH74

LCX920A0-5A3N2

1030

936

687

700

CH74

LCXH10A0-5A3N2

2
2

1180

1073

787

800

CH74

LCXH11A0-5A3N2

1300

1182

867

900

CH74

LCXH13A0-5A3N2

1500

1364

1000

1000

CH74

LCXH15A0-5A3N2

2
540–675 Vdc Liquid Cooled Inverter Units

2

Drive Output

2

Current
Thermal
Ith (A)

2
2
2

Motor Output Power
Rated Cont.
IL (A)

Rated Cont.
IH (A)

Optimum Motor
at Ith 400V (kW)

Optimum Motor
at Ith 500V (kW)

Power Loss
c/a/T
(kW)

Chassis

Catalog Number
LCX016A0-4A7B2

16

15

11

7.5

11

0.4/0.2/0.6

CH3

22

20

15

11

15

0.5/0.2/0.7

CH3

LCX022A0-4A7B2

31

28

21

15

18.5

0.7/0.2/0.9

CH3

LCX031A0-4A7B2

38

35

25

18.5

22

0.8/0.2/1.0

CH3

LCX038A0-4A7B2

45

41

30

22

30

1.0/0.3/1.3

CH3

LCX045A0-4A7B2

61

55

41

30

37

1.3/0.3/1.5

CH3

LCX061A0-4A7B2

2

72

65

48

37

45

1.2/0.3/1.5

CH4

LCX072A0-4A7N2

87

79

58

45

55

1.5/0.3/1.8

CH4

LCX087A0-4A7N2

2

105

95

70

55

75

1.8/0.3/2.1

CH4

LCX105A0-4A7N2

2

140

127

93

75

90

2.3/0.3/2.6

CH4

LCX140A0-4A7N2

168

153

112

90

110

2.5/0.3/2.8

CH5

LCX168A0-4A7N2

2

205

186

137

110

132

3.0/0.4/3.4

CH5

LCX205A0-4A7N2

261

237

174

132

160

4.0/0.4/4.4

CH5

LCX261A0-4A7N2

2

300

273

200

160

200

4.5/0.4/4.9

CH61

LCX300A0-4A7N2

385

350

257

200

250

5.5/0.5/6.0

CH61

LCX385A0-4A7N2

2

460

418

307

250

315

5.5/0.5/6.0

CH62

LCX460A0-4A7N2

2

520

473

347

250

355

6.5/0.5/7.0

CH62

LCX520A0-4A7N2

590

536

393

315

400

7.5/0.6/8.1

CH62

LCX590A0-4A7N2

2

2
2
2
2
V6-T2-266

Volume 6—Solid-State Motor Control CA08100007E—May 2014 www.eaton.com

2.9

Adjustable Frequency Drives
LCX9000 Liquid Cooled Drives

LCX9000 Liquid Cooled
Drives

540–675 Vdc Liquid Cooled Inverter Units, continued

2

Drive Output
Current

Motor Output Power

2

Thermal
Ith (A)

Rated Cont.
IL (A)

Rated Cont.
IH (A)

Optimum Motor
at Ith 400V (kW)

Optimum Motor
at Ith 500V (kW)

Power Loss
c/a/T
(kW)

Chassis

Catalog Number

650

591

433

355

450

8.5/0.6/9.1

CH62

LCX650A0-4A7N2

730

664

487

400

500

10.0/0.7/10.7

CH62

LCX730A0-4A7N2

820

745

547

450

560

12.5/0.8/13.3

CH63

LCX820A0-4A7N2

920

836

613

500

600

14.4/0.9/15.3

CH63

LCX920A0-4A7N2

1030

936

687

560

700

16.5/1.0/17.5

CH63

LCXH10A0-4A7N2

1150

1045

766

600

750

18.4/10.1/19.5

CH63

LCXH11A0-4A7N2

1370

1245

913

700

900

15.5/1.0/16.5

CH64

LCXH13A0-4A7N2

1640

1491

1093

900

1100

19.5/1.2/20.7

CH64

LCXH16A0-4A7N2

2060

1873

1373

1100

1400

26.5/1.5/28.0

CH64

LCXH20A0-4A7N2

2300

2091

1533

1250

1500

29.6/1.7/31.3

CH64

LCXH23A0-4A7N2

2470

2245

1647

1300

1600

36.0/2.0/38.0

2*CH64

LCXH24A0-4A7N2

2950

2681

1967

1550

1950

39.0/2.4/41.4

2*CH64

LCXH29A0-4A7N2

3710

3372

2473

1950

2450

48.0/2.7/50.7

2*CH64

LCXH37A0-4A7N2

4140

3763

2760

2150

2700

53.0/3.0/66.0

2*CH64

LCXH41A0-4A7N2

2
2
2
2
2
2
2
2
2

710–930 Vdc Liquid Cooled Inverter Unit

2

Drive Output
Current

2

Motor Output Power

Thermal
Ith (A)

Rated Cont.
IL (A)

Rated Cont.
IH (A)

Optimum Motor
at Ith 400V (kW)

Optimum Motor
at Ith 500V (kW)

Power Loss
c/a/T
(kW)

170

155

113

110

160

4.5/0.2/4.7

CH61

LCX170A0-5A7N2

208

189

139

132

200

5.5/0.3/5.8

CH61

LCX208A0-5A7N2

261

237

174

160

250

5.5/0.3/5.8

CH61

LCX261A0-5A7N2

325

295

217

200

300

6.5/0.3/6.8

CH62

LCX325A0-5A7N2

385

350

257

250

355

7.5/0.4/7.9

CH62

LCX385A0-5A7N2

416

378

277

250

355

8.0/0.4/8.4

CH62

LCX416A0-5A7N2

460

418

307

300

400

8.5/0.4/8.9

CH62

LCX460A0-5A7N2

502

456

335

355

450

10.0/0.5/10.5

CH62

LCX502A0-5A7N2

590

536

393

400

560

10.0/0.5/10.5

CH63

LCX590A0-5A7N2

650

591

433

450

600

13.5/0.7/14.2

CH63

LCX650A0-5A7N2

750

682

500

500

700

16.0/0.8/16.8

CH63

LCX750A0-5A7N2

820

745

547

560

800

16.0/0.8/16.8

CH64

LCX820A0-5A7N2

920

836

613

650

850

18.0/0.9/18.9

CH64

LCX920A0-5A7N2

1030

936

687

700

1000

19.0/1.0/20.0

CH64

LCXH10A0-5A7N2

1180

1073

787

800

1100

21.0/10.1/20.1

CH64

LCXH11A0-5A7N2

1300

1182

867

900

1200

27.0/1.4/28.4

CH64

LCXH13A0-5A7N2

Chassis

Catalog Number

1500

1364

1000

1050

1400

32.0/1.6/33.6

CH64

LCXH15A0-5A7N2

1700

1545

1133

1150

1550

N/A

CH64

LCXH17A0-5A7N2

1850

1682

1233

1250

1650

34.2/1.8/36.0

2*CH64

LCXH18A0-5A7N2

2120

1927

1413

1450

1900

37.8/2.0/39.8

2*CH64

LCXH21A0-5A7N2

2340

2127

1560

1600

2100

48.6/2.5/51.1

2*CH64

LCXH23A0-5A7N2

2700

2455

1800

1850

2450

57.6/3.0/60.6

2*CH64

LCXH27A0-5A7N2

3100

2818

2066

2150

2800

N/A

2*CH64

LCXH31A0-5A7N2

2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2

Volume 6—Solid-State Motor Control CA08100007E—May 2014 www.eaton.com

V6-T2-267

2.9
2
2

Adjustable Frequency Drives
LCX9000 Liquid Cooled Drives

Options
9000X Series Option Board Kits

2

The 9000X Series drives can accommodate a wide selection of expander and adapter option boards to
customize the drive for your application needs. The drive’s control unit is designed to accept a total of
five option boards.

2

The 9000X Series factory installed standard board configuration includes an A9 I/O board and an A2
relay output board, which are installed in slots A and B.

2

Option Boards

Option Board Kits

2
2
2
2

Option Kit Description 1

Allowed Slot
Locations 2

Field
Installed
Catalog
Number

Factory
Installed
Option
Designator

SVX Ready Programs
Local/
Basic Remote Standard

MSS

PID

Multi-P. PFC

Standard I/O Cards
A

D E
B C

2 RO (NC-NO)

B

OPTA2

—

■

■

■

■

■

■

■

6 DI, 1 DO, 2 AI, 1AO, 1 +10 Vdc ref,
2 ext +24 Vdc/EXT +24 Vdc

A

OPTA9

—

■

■

■

■

■

■

■

2

Extended I/O Cards
2 RO, therm

B

OPTA3

A3

—

■

■

■

■

■

■

2

Encoder low Volt +5V/15V/24V

C

OPTA4

A4

—

■

■

■

■

■

■

Encoder high Volt +15V/24V

C

OPTA5

A5

—

■

■

■

■

■

■

2

Dual encoder +15V/24V

C

OPTA7

A7

—

■

■

■

■

■

■

6 DI, 1 DO, 2 AI, 1 AO

A

OPTA8

A8

—

2

■

■

■

■

■

■

3 DI (encoder 10–24V), out +15V/+24V,
2 DO (pulse+direction)—SPX only

C

OPTAE

AE

■

■

■

■

■

■

■

2

6 DI, 1 ext +24 Vdc/EXT +24 Vdc

B, C, D, E

OPTB1

B1

—

—

—

—

—

■

■

1 RO (NC-NO), 1 RO (NO), 1 therm

B, C, D, E

OPTB2

B2

—

—

—

—

—

■

■

1 AI (mA isolated), 2 AO (mA isolated),
1 ext +24 Vdc/EXT +24 Vdc

B, C, D, E

OPTB4

B4

—

■

■

■

■

■

■

3 RO (NO)

B, C, D, E

OPTB5

B5

—

—

—

—

—

■

■

1 ext +24 Vdc/EXT +24 Vdc, 3 Pt100

B, C, D, E

OPTB8

B8

—

—

—

—

—

—

—

1 RO (NO), 5 DI 42–240 Vac input

B, C, D, E

OPTB9

B9

—

—

—

—

—

■

■

2

SPI, absolute encoder

C

OPTBB

BB

—

—

—

—

—

—

—

2

Modbus

D, E

OPTC2

C2

■

■

■

■

■

■

■

Johnson Controls N2

D, E

OPTC2

CA

—

—

—

—

—

—

—

2

PROFIBUS DP

D, E

OPTC3

C3

■

■

■

■

■

■

■

LonWorks

D, E

OPTC4

C4

■

■

■

■

■

■

■

2

PROFIBUS DP (D9 connector)

D, E

OPTC5

C5

■

■

■

■

■

■

■

2

CANopen (slave)

D, E

OPTC6

C6

■

■

■

■

■

■

■

DeviceNet

D, E

OPTC7

C7

■

■

■

■

■

■

■

2

Modbus (D9 Type connector)

D, E

OPTC8

C8

■

■

■

■

■

■

■

Modbus TCP

D, E

OPTCI

CI

■

■

■

■

■

■

■

2

Adapter—SPX only

D, E

OPTD1

D1

■

■

■

■

■

■

■

Adapter—SPX only

D, E

OPTD2

D2

■

■

■

■

■

■

■

2

RS-232 with D9 connection

D, E

OPTD3

D3

■

■

■

■

■

■

■

9000X Series standard keypad

—

KEYPADSTD

—

—

—

—

—

—

—

■

9000X Series remote mount keypad unit
(keypad not included, includes 10 ft cable,
keypad holder, mounting hardware)

—

OPTRMTKIT-9000X

—

—

—

—

—

—

—

—

2
2
2

Communication Cards 3

Keypad

2
2
2

Notes
1 AI = Analog Input; AO = Analog Output, DI = Digital Input, DO = Digital Output, RO = Relay Output
2 Option card must be installed in one of the slots listed for that card. Slot indicated in bold is the preferred location.
3 OPTC2 is a multi-protocol option card.

2
2
V6-T2-268

Volume 6—Solid-State Motor Control CA08100007E—May 2014 www.eaton.com

Adjustable Frequency Drives
LCX9000 Liquid Cooled Drives

2.9

Line Reactors
The line reactor carries out
several functions in the liquid
cooled drive. Connection of
the line reactor is necessary
except if you have a
component in your system
that performs the same tasks
(e.g. a transformer). The line

reactor is needed as an
essential component for
motor control, to protect the
input and DC-link components
against abrupt changes of
current and voltage as well as
to function as a protection

2

against harmonics. The line
reactors are included in the
standard delivery of liquidcooled drives (not inverters).
However, you can also order
your drive without a line
reactor.

2
2
2
2

Line Reactor Specifications

2

Drive Rating
480V

Drive Rating
690V

Thermal
Current
(A)

Nominal
Inductance
(μH) A/B 1

Calculated
Loss
(W)

Choke
Catalog Number
(690 Vac)

16 to 22A

12 to 23A

23

1900

145

CHK0023N6A0

31 to 38A

31 to 38A

38

1100

170

CHK0038N6A0

45 to 61A

46 to 62A

62

700

210

CHK0062N6A0

72 to 87A

72 to 87A

87

480

250

CHK0087N6A0

105 to 140A

105 to 140A

145

290

380

CHK0145N6A0

168 to 261A

170 to 261A

261

139/187

460

CHK0261N6A0

300 to 385A

325 to 385A
820 to 1180A 2

400

90/126

570

CHK0400N6A0

2

460 to 520A
1370A 2

416 to 502A
1300 to 1500A 2

520

65/95

610

CHK0520N6A0

2

590 to 650A
1640A 2

590 to 650A

650

51/71

840

CHK0650N6A0

2

730A
2060A 2

—

730

45/61

850

CHK0730N6A0

2

820A
2300A 2

750A

N/A

N/A

N/A

CHK0820N6A0

2

920 to 1030A

—

1000

30/41

950

CHK1030N6A0

1150A

—

1150

26/36

1000

CHK1150N6A0

2

2
2
2
2

2

Dimensions, see Page V6-T2-273.
Notes
1 Inductances for different supply voltages: A = 400–480 Vac; B = 500–690 Vac.
2 Drives require three chokes of the designated catalog number with six-pulse supply.

2
2
2
2
2
2
2
2
2
2
2
2
2

Volume 6—Solid-State Motor Control CA08100007E—May 2014 www.eaton.com

V6-T2-269

2.9

Adjustable Frequency Drives
LCX9000 Liquid Cooled Drives

2

Technical Data and Specifications

2

LCX9000 Products

2
2
2
2
2
2
2
2
2

Description

Specification

Description

Specification

Ambient Conditions

General Specifications
Line voltage

400 to 500 Vac; 525 to 690 Vac; (–10% to 10%)
465 to 800 Vdc; 640 to 1100 Vdc; (–0 to 0%)

Ambient operating temperature

14°F (–10°C), no frost to 122°F (50°C) at Ith
122 to 158°F (50 to 70°C), derating required

Frequency

50/60 Hz

Storage temperature

Line voltage variation

–10% to 10%

–40°F to 158°F (–40 to 70°C)
No liquid in heatsink under 32°F (0°C)

Input frequency variation

45–66 Hz

Continuous output current

Rated current at incoming cooling liquid
temperature of 30°C

Output frequency

0–320 Hz

Drive efficiency

>95%

Power factor (displacement)

0.96

Liquid coolant pressure

87 psi (6 bar) maximum

Liquid coolant flow rate

1.3 to 7.9 gal./min. (5 to 30 liter/min.)
minimum depending on drive size

Liquid coolant fittings

Standard quick connect, NPT

Relative humidity

5–96% RH, noncondensing, no dripping water

Air quality

Chemical vapors:
IEC 721-3-3, unit in operation, class 3C2
Mechanical particles:
IEC 721-3-3, unit in operation, class 3S2 (no conductive
dust allowed); No corrosive gases

Altitude

Up to 1,000m: 100% load capacity (no derating)
Above 1,000m: Derating of 1% per each 100m required

Vibration

EN 50178, EN 60068-2-6; 5–150 Hz
Displacement amplitude: 0.25 mm (peak) at 3–31 Hz
Max. acceleration amplitude: 1G at 31–150 Hz

Shock

EN 50178, EN 60068-2-27, UPS drop test
(for applicable UPS weights)
Storage and shipping: Max. 15G, 11 ms (in package)
IP00 open frame standard in entire kW/hp range

Operating ambient temperature

–10/50°C

2

Storage temperature

–40/70°C

Enclosure class

Humidity

95% maximum (non-condensing)

EMC

2

Altitude

3300 ft (1000 m) maximum without derating

Immunity

Fulfils all EMC immunity requirements

Enclosure

IP00

2

Emissions

EMC level N; EMC level T for IT networks

Warranty

Standard terms, 3 years with certified start-up

Safety

2

Input voltage (Vin)

400–500 Vac; 525–690 Vac; (–10%–10%)
465–800 Vdc; 640–1100 Vdc; (–0–0%)

Input frequency (fin)

45–66Hz

Control Connections

2

Connection to mains

Once per minute or less (normal case)

Analog input voltage

0 to +10V, Ri = 200 kohm (–10V to +10V joystick control)
Resolution 0.1%; accuracy ±1%

2

Analog input current

Output voltage

0–Vin

0(4)–20 mA, Ri = 250 ohm differential

Digital inputs

6 positive or negative logic; 18–24 Vdc

Continuous output current

2

Rated current at nominal inflow cooling water
temperature of 30°C; Overload 2 sec./20 sec.

Starting current

2

Rated current at 2 sec./20 sec. if output frequency
<30 Hz and temperature of heatsink <149°F (65°C)

Output frequency

0–320 Hz (standard); 7200 Hz (special software)

2

Frequency resolution

Application dependent

2

Control method

Frequency control (V/f)
Open loop: Sensorless vector control
Closed loop: Frequency control
Closed loop: Vector control

Switching frequency

Adjustable with parameter 2.6.9

2

Mains Connection

Motor Connection

Control Characteristics

2
2

480V 1

2
2
2

Approvals

575V 1
Frequency reference

Auxiliary voltage

+24V, ±15%, max. 250 mA

Output reference voltage

+10V, +3%, max. load 10 mA

Analog output

0(4)–20 mA, RL max. 500 ohm
Resolution 10 bits; accuracy ±2%

Digital outputs

Open collector output, 50 mA/48V

Relay outputs

Two programmable change-over relay outputs
Switching capacity: 24 Vdc/8A, 250 Vac/8A,
125 Vdc/0.4A
Min. switching load: 5V/10 mA

Note
1 Derating required if higher switching frequency than the default is used.

Up to and including 61-Amp size:
1–16 kHz (factory default, 10 kHz)
From 72-Amp size:
1–12 kHz (factory default, 3.6 kHz)
1–6kHz (factory default, 1.5kHz)
Analog input: resolution 0.1% (10 bits); accuracy ±1%
Panel reference: resolution 0.01 Hz

Field weakening point

30–320 Hz

2

Acceleration time

0.1–3000 seconds

2

Deceleration time

0.1–3000 seconds

Braking torque

DC brake: 30% x Tn (without brake option)

2
V6-T2-270

EN 50178, EN 60204-1, CE, UL, CUL, FI,
GOST R, IEC 61800-5
(See unit nameplate for more detailed approvals.)

Volume 6—Solid-State Motor Control CA08100007E—May 2014 www.eaton.com

Adjustable Frequency Drives
LCX9000 Liquid Cooled Drives

2.9

LCX9000 Products, continued
Description

Specification

Description

Protections

Protections, continued

Overvoltage protection

Overcurrent protection

2

Yes

2

480V

911V

Motor overload protection

Yes

575V

1200V

Motor stall protection

Yes

Motor underload protection

Yes

Short-circuit protection

Yes (+24V and +10V reference voltages)

Undervoltage protection
480V

333V

575V

461V

2

Specification

2
2

Liquid Cooling

Ground fault protection

In case of ground fault in motor or motor cable,
only the drive is protected

Mains supervision

Trips if any of the input phases are missing (drives only)

Motor phase supervision

Trips if any of the output phases are missing

Drinking water
Water-glycol mixture

Temperature of cooling agent

32 to 86°F (0 to 30°C) at Ith for input;
86 to 149°F (30 to 65°C)
Max. temperature rise during circulation: 9°F (5°C), no
condensation allowed

System max. working pressure

87 psi (6 bar)

System max. peak pressure

580 psi (40 bar)

Pressure loss (at nominal flow)

Varies according to size

Unit overtemperature protection
Alarm limit

149°F (65°C) for heatsink, 158°F (70°C) for circuit boards

Trip limit

158°F (70°C) for heatsink, 185°F (85°C) for circuit boards

2

Allowed cooling agents

2
2
2
2
2

Wiring Diagrams

2

Cooling System Diagrams

2

Example of a Typical Cooling System

2
30.0C

2

18.0C

2
2
2

Heat
Exchanger

2
2

35.4C

2

26.1C

2
2
2
2
2
2
2
2
2

Volume 6—Solid-State Motor Control CA08100007E—May 2014 www.eaton.com

V6-T2-271

2.9

Adjustable Frequency Drives
LCX9000 Liquid Cooled Drives

2

Example PI-Diagram of a Typical Cooling System and Connections

2

Cooling Water Inlet
Frequency
Converters

2
2
2
2
2

Cooling Water Outlet

2
2
Customer Delivery

2
2
2
2
2

I/O Board Diagrams
A9 Option Board Control Wiring
Basic I/O Board A9

2
2
2
2
2
2
2

+10 V ref

1

AI1+

2

GND

3

AI2+

4

AI2-

5

24Vout

6

GND

7

DIN1

8

DIN2

9

Reference
(voltage)

Reference
(current)
Control Voltage Output

DIN3 10

24V

CMA 11

GND

24Vout 12

2

GND

13

DIN4 14

2

DIN5 15

2

DIN6 16
CMB

2
2
2
2

17

24V
GND

AO1+ 18

0 (4)/20mA

AO1- 19

RL<500W

DO1

+ V<+48V
I<50mA

20

Dotted lines indicate the connections for inverted signals

2
2
V6-T2-272

Volume 6—Solid-State Motor Control CA08100007E—May 2014 www.eaton.com

Adjustable Frequency Drives
LCX9000 Liquid Cooled Drives

2.9

A2 Option Board Wiring

2

Basic Relay Board A2
RO1/1

21

RO1/2

22

RO1/3

23

RO2/1

24

RO2/2

25

RO2/3

26

2
RL

2
AC / DC

2

Switching:
<8 A / 24 Vdc
<0.4 A / 125 Vdc
<8 A / 250 Vac
<2 Arms
Continuous

2
2
2
2
2

Dimensions

2

Approximate Dimensions in Inches (mm)

Line Reactors
Sizes Up To 61A

2

Sizes Larger Than 61A

ZWY V X U

2

Mains

2
2

H1

2
2

H1
W1
D1

2

Converters
W1

Catalog Number

2

D1

H1

W1

D1

2

Weight
Lbs (kg)

CHK0023N6A0

7.01 (178)

9.06 (230)

4.76 (121)

22 (10)

CHK0038N6A0

8.23 (209)

10.63 (270)

5.71 (145)

33 (15)

CHK0062N6A0

8.39 (213)

11.81 (300)

6.30 (160)

44 (20)

CHK0087N6A0

9.13 (232)

11.81 (300)

6.69 (170)

57 (26)

CHK0145N6A0

11.50 (292)

11.81 (300)

7.28 (185)

82 (37)

CHK0220N6A0

12.05 (306)

13.86 (352)

7.28 (185)

119 (54)

CHK0325N6A0

13.66 (347)

13.86 (352)

7.28 (185)

132 (60)

CHK0460N6A0

16.54 (423)

13.70 (348)

9.41 (239)

203 (92)

CHK0520N6A0

17.60 (447)

15.51 (394)

10.71 (272)

231 (105)

CHK0590N6A0

20.43 (519)

15.51 (394)

10.71 (272)

276 (125)

CHK0650N6A0

20.51 (521)

15.51 (394)

10.71 (272)

276 (125)

CHK0750N6A0

24.72 (628)

15.51 (394)

11.10 (282)

331 (150)

CHK0820N6A0

24.72 (628)

15.51 (394)

11.10 (282)

331 (150)

CHK1000N6A0

22.68 (576)

19.57 (497)

11.85 (301)

441 (200)

CHK1150N6A0

22.83 (580)

19.57 (497)

11.85 (301)

441 (200)

2
2
2
2
2
2
2
2
2
2
2

Volume 6—Solid-State Motor Control CA08100007E—May 2014 www.eaton.com

V6-T2-273

2.9
2
2

Adjustable Frequency Drives
LCX9000 Liquid Cooled Drives

Approximate Dimensions in Inches (mm)

LCX9000 Drives
Chassis Size, CH3

2

H2

2

W1
W2

R2

2
2
2

Top
H1

2
2
2
2

H3

2
2
2
2

W3

Bottom

D1

R1

Front

Side

Voltage

Amps

H1

H2

H3

D1

W1

W2

W3

R1 Dia.

R2 Dia.

380–500 Vac

16–61

16.97
(431.0)

0.53
(13.5)

0.59
(15.0)

9.69
(246.0)

6.30
(160.0)

4.80
(122.0)

4.80
(122.0)

0.39
(10.0)

0.35
(9.0)

Weight
Lbs (kg)
66 (30)

Chassis Size, CH4

2

W1
W2

H2

2

R1

2
2
2
H1

2

Top

2
2
H3

2
2
2
2

R1

W3
Right Side

D1

Front

Bottom

Left Side

Voltage

Amps

H1

H2

H3

D1

W1

W2

W3

R1 Dia.

R2 Dia.

Weight
Lbs (kg)

380–500 Vac

72–140

19.41
(493.0)

0.49
(12.5)

1.77
(45.0)

10.14
(257.5)

7.60
(193.0)

3.35
(85.0)

5.24
(133.0)

0.39
(10.0)

—

77 (35)

2
2
2
V6-T2-274

Volume 6—Solid-State Motor Control CA08100007E—May 2014 www.eaton.com

Adjustable Frequency Drives
LCX9000 Liquid Cooled Drives

2.9

Approximate Dimensions in Inches (mm)

2

Chassis Size, CH5

2

W1
W2

2

R1

2
2
2
2

Top

H1 H3

2
2
2
2

H2
W3

Bottom

D1

R1

Front

2

Side

Voltage

Amps

H1

H2

H3

D1

W1

W2

W3

R1 Dia.

R2 Dia.

Weight
Lbs (kg)

2

380–500 Vac

168–261

21.77
(553.0)

1.30
(33.0)

19.88
(505.0)

10.39
(264.0)

9.69
(246)

3.94
(100.0)

7.87
(200.0)

0.51
(13.0)

—

88 (40)

2
2

Chassis Size, CH61

2

W1
R2

2

W2

2
2
2
H3

2

H1

Top

2
2
2

H2

2

R1

Right Side

Bottom

W3

D1

Front

Left Side

2

Voltage

Amps

H1

H2

H3

D1

W1

W2

W3

R1 Dia.

R2 Dia.

380–500 Vac

300–385

525–690 Vac

170–208

25.91
(658.0)

2.09
(53.0)

23.23
(590.0)

14.69
(373.0)

9.69
(246.0)

3.94
(100.0)

5.91
(150.0)

0.55
(14.0)

0.51
(13.0)

Weight
Lbs (kg)
121 (55)

2
2
2
2

Volume 6—Solid-State Motor Control CA08100007E—May 2014 www.eaton.com

V6-T2-275

2.9
2
2

Adjustable Frequency Drives
LCX9000 Liquid Cooled Drives

Approximate Dimensions in Inches (mm)
Liquid-Cooled Inverter—Chassis Size, CH62
W1

2

R2

W2

2
2
2
2

Top
H1

H3

2
2
2

H2

2
2
2
2
2

D1
Bottom

R1

W3

Side

Front

Voltage

Amps

H1

H2

H3

D1

W1

W2

W3

R1 Dia.

R2 Dia.

540–675 Vdc

460–730

710–930 Vdc

325–502

26.50
(673)

2.0
(53)

23.23
(590)

14.69
(373)

9.69
(246)

3.94
(100)

5.91
(150)

0.55
(14)

0.51
(13)

Chassis Size, CH63

2

H2

2
2
2
2

H3

2

H1

Top

2
2
2
2

R1

2
2
2
2

Bottom
Right Side
Voltage

W2
W1

D1

Front

Left Side

Amps

H1

H2

H3

D1

W1

W2

R1 Dia.

380–500 Vac

820–1030

525–690 Vac

590–750

36.36
(923.5)

0.91
(23.0)

34.39
(873.5)

15.35
(390.0)

19.88
(505.0)

13.98
(355.0)

0.43
(11.0)

2
V6-T2-276

Volume 6—Solid-State Motor Control CA08100007E—May 2014 www.eaton.com

Weight
Lbs (kg)
264 (120)

2.9

Adjustable Frequency Drives
LCX9000 Liquid Cooled Drives

Approximate Dimensions in Inches (mm)

2

Liquid-Cooled Inverter with Mounting Bracket, Chassis Size CH64, IP90

2
2
2
2
2
2

Top

Bottom

2

H2

2
2
2
2
H3

2

H1

2
2
2
2
2
W2

W2

W2

Right Side

2

R1

W1

D1

Front

Left Side

2

Amps

H1

H2

H3

D1

W1

W2

R1 Dia.

2

540–675 Vdc

1370–4140

710–930 Vdc

820–3100

36.38
(924)

1.03
(26)

34.37
(873)

15.35
(390)

29.37
(746)

7.87
(200)

0.43
(11)

2

Voltage

2
2
2
2
2
2
2
2
Volume 6—Solid-State Motor Control CA08100007E—May 2014 www.eaton.com

V6-T2-277

2.9
2
2

Adjustable Frequency Drives
LCX9000 Liquid Cooled Drives

Approximate Dimensions in Inches (mm)
Chassis Size, CH72
W1

R1

2
2
2
2
2

Top

H3 H1

2
2
2
2
Bottom

2
2

H2

2
2
2

W1

R2

D1

Front

Side

Voltage

Amps

H1

H2

H3

D1

W1

R1 Dia.

R2 Dia.

380–500 Vac

460–730

525–690 Vac

261–502

42.38
(1076.5)

1.57
(40.0)

39.37
(1000.0)

14.65
(372.0)

7.87
(200.0)

0.55
(14.0)

0.51
(13.0)

2
2
2
2
2
2
2
2
2
2
2
2
2
2
V6-T2-278

Volume 6—Solid-State Motor Control CA08100007E—May 2014 www.eaton.com

Weight
Lbs (kg)
198 (90)

2.9

Adjustable Frequency Drives
LCX9000 Liquid Cooled Drives

Approximate Dimensions in Inches (mm)

2

Chassis Size, CH74

2

R2

2
2
2
2
2
2

Top
H1

H3

2
2
2
2
2
2

Bottom
H2
W2

W3
W4

Front

Voltage

2

D1

R1
W4
W1

2

Side

Amps

H1

H2

H3

D1

W1

W2

W3

W4

R1 Dia.

R2 Dia.

380–500 Vac

1370–2300

525–690 Vac

820–1500

42.38
(1076.5)

1.57
(40.0)

39.37
(1000.0)

14.65
(372.0)

29.06
(738.0)

0.91
(23.0)

7.87
(200.0)

9.69
(246)

0.51
(13.0)

0.55
(14.0)

Weight
Lbs (kg)
617 (280)

2
2
2
2

Control Unit

2

D1
H2

D2

2
2

H1

2

H3

2
2

Bottom

2

W1
Front

Side

Back

H1

H2

H3

D1

D2

W1

2

12.93
(328.5)

0.33
(8.5)

11.81
(300.0)

2.95
(75.0)

0.33
(8.5)

5.75
(146.0)

2
2

Volume 6—Solid-State Motor Control CA08100007E—May 2014 www.eaton.com

V6-T2-279

2.10
2

Adjustable Frequency Drives
SPA9000/SPN9000/SPI9000 Common DC Bus Drives

SPA9000/SPN9000/SPI9000 Common DC Bus Drive Products

Contents
Description

2

Page

SPA9000/SPN9000/SPI9000 Common DC Bus Drives
Application Description . . . . . . . . . . . . . . . . . .
V6-T2-281
Product Comparison . . . . . . . . . . . . . . . . . . . .
V6-T2-281
Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
V6-T2-282
Standards and Certifications . . . . . . . . . . . . . .
V6-T2-282
Catalog Number Selection . . . . . . . . . . . . . . . .
V6-T2-282
Product Selection . . . . . . . . . . . . . . . . . . . . . . .
V6-T2-284
Options . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
V6-T2-287
Technical Data and Specifications . . . . . . . . . .
V6-T2-288
Wiring Diagrams . . . . . . . . . . . . . . . . . . . . . . .
V6-T2-290
Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . .
V6-T2-291

2
2
2
2
2
2
2
2
2
2
2
2
2
2

Product Description
Eaton offers a comprehensive
range of common DC bus
drive products. The product
family covers a number of
front-end units and inverter
units in the entire power
range from 1-1/2 to 2000
horsepower at 460V and
690V. The drive components
are built on the SPX9000
technology.

2
2
2
2

Front-End Units
The front-end units convert a
mains AC voltage and current
into a DC voltage and current.
The power is transferred from
the mains to a common DC
bus (and, in certain cases,
vice versa).
The SPA (active front-end)
unit is a bidirectional
(regenerative) power
converter for the front end
of a common DC bus drive
line up. An external LCL filter
is used at the input. This unit
is suitable in applications
where low mains harmonics
are required.

Inverter Unit
The SPN (non-regenerative
front-end) unit is a unidirectional (motoring) power
converter for the front-end
of a common DC bus drive
line-up. The device operates
as a diode bridge using diode/
thyristor components. A
dedicated external choke is
used at the input. The unit
has the capacity to charge a
common DC bus. This unit is
suitable as a rectifying device
when a “normal” level of
harmonics is accepted and
no regeneration to the mains
is required.

2
2
2
2
2
2
2
2
2
2
V6-T2-280

Volume 6—Solid-State Motor Control CA08100007E—May 2014 www.eaton.com

The SPI9000 Inverter Unit is a
bidirectional DC-fed power
inverter for the supply and
control of AC motors. The
inverter is supplied from a
common DC bus drive lineup. A charging circuit is
needed in case a connection
to a live DC bus is required.
The DC side charging circuit
is integrated up to 75 kW
(FR4–FR8) and external
for higher power ratings
(FI9–FI14).

Adjustable Frequency Drives
SPA9000/SPN9000/SPI9000 Common DC Bus Drives

2.10

Application Description

2

The common DC bus product portfolio fulfills all solution demands with a flexible architecture.

2

Front end units are selected according to the level of harmonics and power requirements. Typical
drive system configurations are illustrated the following figures.
SPA + Inverters

SPN + Inverters

Active
Front End
(SPA)

2

Combination Configuration

Non-regenerative
Front End
(SPN)

Non-regenerative
Front End
(SPN) Alternative

3

3

3

3

2

2

2

2

2

2

2

2

2

2

3

3

3

3

3

3

Inverter

Inverter

Inverter

Inverter

Inverter

Common DC Bus

●

Low harmonics, -Pmains
~
~ +Pmains/Pmains < PINU

●

Low total mains power,
Pmains < PINU

●

Suitable for almost every
application

●

Suitable e.g. for small
processing line with
un- and recoiler, em-stop
coasting

2
2
2

2

2

3

3

Inverter

Inverter

2

Active
Front End
(SPA) Alternative

2
2

Inverter

2

Common DC bus
components are used in a
multitude of combinations.
Drives which are braking can
transfer the energy directly to
the drives in motoring mode.

2
2
2

Product Comparison

2

Advantages over Conventional Front Ends

2
2

Eaton Front Ends vs. Conventional

Input device

Non-Regenerative
Front End

Active
Front End

Conventional
Regenerative Front End 1

Choke (L)

Filter (LCL)

Choke or auto-transformer (L)

Bridge type

Diode/thyristor bridge

IGBT bridge, two-level type

Anti-parallel connected thyristor bridge

Type of operation

Controlled half-bridge

High frequency modulation
(1.5 to 3.6 kHz)

Firing angle controlled

Direction of power

Motoring

Motoring and regenerating

Motoring and regenerating

2
2
2

Charging

Constant current

External required

Usually internal

2

DC voltage

Nominal (approx. 1.35
alternative UN)

Stable at +10% of nominal
(approx. 110% of 1.35
alternative UN)

Lowered DC voltage for commutation margin
(e.g. 17% fi approx. 83% of 1.35 alternative UN) or
autotransformer on regenerative bridge

2

THD

Similar to six-pulse bridge
normal <40%

Very low

Similar to six-pulse bridge or worse

2
2

Note
1 Conventional regenerative front end (a.k.a. “anti-parallel thyristor bridge”) is not available from Eaton.

2
2
2
2
2
2
2

Volume 6—Solid-State Motor Control CA08100007E—May 2014 www.eaton.com

V6-T2-281

2.10

Adjustable Frequency Drives
SPA9000/SPN9000/SPI9000 Common DC Bus Drives

2

Features

2

Standard Features

2

Feature

FR4, 6, 7

FR8

FI9–FI14

FI9–FI14

FI9

IP00

—

■

■

■

■

IP21

■

—

—

—

—

2

Air cooling

■

■

■

■

■

Standard board

■

■

■

■

2

Varnished board

—

—

—

—

—

2

SPI9000

SPA

SPN

Alphanumeric keypad

■

■

■

■

—

2

EMC class T (EN 61800-3 for IT networks)

■

■

■

■

■

2

Safety CE/UL

■

■

■

■

■

Input choke

—

—

—

—

■

LCL filter

—

—

—

■

—

No integrated charging

—

—

■

■

—

2

Integrated charging (DC side)

■

■

—

—

■

2

Diode/thyristor rectifier

—

—

—

—

■

IGBT

■

■

■

■

—

2

2
2

Standards and Certifications
●

2

●

2

●

●

CE
UL
cUL
EN 61800-5-1 (2003)

2
2
2
2

Catalog Number Selection
Active Front End

SPA 205 A 0 – 4 A 3 N 1

2
Product Family
SPA = Active Front End

2
2

Board Modifications
1 = Standard boards
2 = Varnished boards

Current Rating
480V
575V
205 = 205A
125 = 125A
385 = 385A
325 = 325A
H10 = 1150A
920 = 920A

2
2

Brake Chopper Options
N = No brake chopper circuit

EMC Level
3 = IT network

2

Software Series
A = Standard

2
2

Enclosure Rating
0 = Chassis

2

Keypad
A = Alphanumeric
Voltage Rating
4 = 480V
5 = 575V

2
2
V6-T2-282

Volume 6—Solid-State Motor Control CA08100007E—May 2014 www.eaton.com

Adjustable Frequency Drives
SPA9000/SPN9000/SPI9000 Common DC Bus Drives

2.10

Non-Regenerative Front End

2

SPN 510 A 0 – 4 A 3 N 1

2

Product Family
SPN = Non-regenerative
SPN = front end

2

Board Modifications
1 = Standard boards
2 = Varnished boards

2
2

Brake Chopper Options
N = No brake chopper circuit

Current Rating
480V/575V
510 = 510A

2
EMC Level
3 = IT network

Software Series
A = Standard

2
2

Keypad
A = Alphanumeric
Enclosure Rating
0 = Chassis

2

Voltage Rating
4 = 480V
5 = 575V

2
2

SPI9000 Inverter Unit

2
SPI 016 A 1 – 4 A 3 N 1

Product Family
SPI = Inverter unit

2
2

Board Modifications
1 = Standard boards
2 = Varnished boards

Current Rating
480V (FR4–FR8)
575V (FR6–FR8)
003 = 3.3A
031 = 31A
003 = 3.2A
022 = 22A
007 = 7.6A
038 = 38A
004 = 4.5A
027 = 27A
009 = 9A
061 = 61A
005 = 5.5A
034 = 34A
012 = 12A
071 = 72A
007 = 7.5A
041 = 41A
016 = 16A
087 = 87A
010 = 10A
052 = 52A
023 = 23A
105 = 105A
013 = 13.5A
062 = 62A
018 = 18A
080 = 80A
480V (FI9–FI13)
575V (FI9–FI14)
502 = 502A
140 = 140A
730 = 730A
100 = 100A
590 = 590A
170 = 170A
820 = 820A
125 = 125A
650 = 650A
205 = 205A
920 = 920A
144 = 144A
820 = 820A
245 = 245A
H10 = 1030A
170 = 170A
920 = 920A
300 = 300A
H11 = 1150A
208 = 207A
H10 = 1030A
385 = 385A
H13 = 1300A
261 = 261A
325 = 325A
H13 = 1300A
460 = 460A
H16 = 1600A
385 = 385A
H15 = 1500A
520 = 520A
H19 = 1940A
460 = 460A
H19 = 1900A
590 = 590A
H23 = 2300A
650 = 650A

2
2

Brake Chopper Options
N = No brake chopper circuit

2
2

EMC Level
3 = IT network

2

Keypad
A = Alphanumeric

2
2

Voltage Rating
4 = 480V
5 = 575V

2
2

Enclosure Rating
1 = NEMA Type 1/IP21
0 = Chassis

2
2

Software Series
A = Standard

2
2
2
2
2
Volume 6—Solid-State Motor Control CA08100007E—May 2014 www.eaton.com

V6-T2-283

2.10
2
2

Adjustable Frequency Drives
SPA9000/SPN9000/SPI9000 Common DC Bus Drives

Product Selection
Common DC Bus Drive
Products

2
2
2
2

SPA9000 Active Front End 480V
Low Overload (AC Current)

High Overload (AC Current)

Imax

Frame

IL-cont (A)

I1min (A)

IH-cont (A)

I1min (A)

I2s (A)

Catalog Number

FI9

261

287

205

308

349

SPA205A0-4A3N1

FI10

460

506

385

578

693

SPA385A0-4A3N1

FI13

1300

1430

1150

1725

2070

SPAH11A0-4A3N1

SPN9000 Non-Regenerative Front End 480V

2
2

Low Overload (AC Current)

High Overload (AC Current)

Imax

Frame

IL-cont (A)

I1min (A)

IH-cont (A)

I1min (A)

I2s (A)

Catalog Number

FI9

520

572

460

690

828

SPN460A0-4A3N1

2
2

SPI9000 Inverter Unit 480V

2

Low Overload (AC Current)

High Overload (AC Current)

Imax

Frame

IL-cont (A)

I1min (A)

IH-cont (A)

I1min (A)

I2s (A)

Catalog Number

FR4

4.3

4.7

3.3

5

6.2

SPI003A1-4A3N1

9

9.9

7.6

11.4

14

SPI007A1-4A3N1

12

13.2

9

13.5

18

SPI009A1-4A3N1

16

17.6

12

18

24

SPI012A1-4A3N1

23

25.3

16

24

32

SPI016A1-4A3N1

31

34

23

35

46

SPI023A1-4A3N1

38

42

31

47

62

SPI031A1-4A3N1

46

51

38

57

76

SPI038A1-4A3N1

72

79

61

92

122

SPI061A1-4A3N1

87

96

72

108

144

SPI072A1-4A3N1

105

116

87

131

174

SPI087A1-4A3N1

FR8

140

154

105

158

210

SPI105A0-4A3N1

FI9

170

187

140

210

280

SPI140A0-4A3N1

2

205

226

170

255

336

SPI170A0-4A3N1

2

261

287

205

308

349

SPI205A0-4A3N1

300

330

245

379

444

SPI245A0-4A3N1

385

424

300

450

540

SPI300A0-4A3N1

460

506

385

578

693

SPI385A0-4A3N1

520

572

460

690

828

SPI460A0-4A3N1

590

649

520

780

936

SPI520A0-4A3N1

650

715

590

885

1062

SPI590A0-4A3N1

2

730

803

650

975

1170

SPI650A0-4A3N1

820

902

730

1095

1314

SPI730A0-4A3N1

2

920

1012

820

1230

1476

SPI820A0-4A3N1

1030

1133

920

1380

1656

SPI920A0-4A3N1

1150

1265

1030

1545

1854

SPIH10A0-4A3N1

1300

1430

1150

1720

2070

SPIH11A0-4A3N1

1450

1595

1300

1950

2340

SPIH13A0-4A3N1

1770

1947

1600

2400

2880

SPIH16A0-4A3N1

2150

2365

1940

2910

3492

SPIH19A0-4A3N1

2
2

FR6

2
2
2

FR7

2
2

FI10

2
2

FI12

2

2

FI13

2
FI14

2
2

Note
For filter and line reactor information, see Page V6-T2-286.

2
V6-T2-284

Volume 6—Solid-State Motor Control CA08100007E—May 2014 www.eaton.com

2.10

Adjustable Frequency Drives
SPA9000/SPN9000/SPI9000 Common DC Bus Drives

Common DC Bus Drive
Products

SPA9000 Active Front End 575V

2

Low Overload (AC Current)

High Overload (AC Current)

Imax

Frame

IL-cont (A)

I1min (A)

IH-cont (A)

I1min (A)

I2s (A)

Catalog Number

FI9

144

158

125

188

213

SPA125A0-5A3N1

FI10

385

424

325

488

585

SPA325A0-5A3N1

FI13

1030

1133

920

1380

1656

SPA920A0-5A3N1

2
2
2
2

SPN9000 Non-Regenerative Front End 575V
Low Overload (AC Current)

High Overload (AC Current)

Imax

Frame

IL-cont (A)

I1min (A)

IH-cont (A)

I1min (A)

I2s (A)

Catalog Number

FI9

600

660

510

732

888

SPN510A0-5A3N1

2
2
2

SPI9000 Inverter Unit 575V

2

Low Overload (AC Current)

High Overload (AC Current)

Imax

Frame

IL-cont (A)

I1min (A)

IH-cont (A)

I1min (A)

I2s (A)

Catalog Number

FR6

4.5

5

3.2

5

6.4

SPI003A1-5A3N1

FR7

FR8

FI9

FI10

FI12

FI13

FI14

5.5

6

4.5

7

9

SPI004A1-5A3N1

7.5

8

5.5

8

11

SPI005A1-5A3N1

10

11

7.5

11

15

SPI007A1-5A3N1

13.5

15

10

15

20

SPI010A1-5A3N1

18

20

13.5

20

27

SPI013A1-5A3N1

22

24

18

27

36

SPI018A1-5A3N1

27

30

22

33

44

SPI022A1-5A3N1

34

37

27

41

54

SPI027A1-5A3N1

41

45

34

51

68

SPI034A1-5A3N1

52

57

41

62

82

SPI041A1-5A3N1

62

68

52

78

104

SPI052A0-5A3N1

80

88

62

93

124

SPI062A0-5A3N1

100

110

80

120

160

SPI080A0-5A3N1

125

138

100

150

200

SPI100A0-5A3N1

144

158

125

188

213

SPI125A0-5A3N1

170

187

144

216

245

SPI144A0-5A3N1

208

229

170

255

289

SPI170A0-5A3N1

261

287

208

312

375

SPI208A0-5A3N1

325

358

261

392

470

SPI261A0-5A3N1

385

424

325

488

585

SPI325A0-5A3N1

460

506

385

578

693

SPI385A0-5A3N1

502

552

460

690

828

SPI460A0-5A3N1

590

649

502

753

904

SPI502A0-5A3N1

650

715

590

885

1062

SPI590A0-5A3N1

750

825

650

975

1170

SPI650A0-5A3N1

920

1012

820

1230

1476

SPI820A0-5A3N1

1030

1133

920

1380

1656

SPI920A0-5A3N1

1180

1298

1030

1464

1755

SPIH10A0-5A3N1

1500

1650

1300

1950

2340

SPIH13A0-5A3N1

1900

2090

1500

2250

2700

SPIH15A0-5A3N1

2250

2475

1900

2782

3335

SPIH19A0-5A3N1

2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2

Note
For filter and line reactor information, see Page V6-T2-286.

Volume 6—Solid-State Motor Control CA08100007E—May 2014 www.eaton.com

2
V6-T2-285

2.10

Adjustable Frequency Drives
SPA9000/SPN9000/SPI9000 Common DC Bus Drives

2

LCL Filters

Line Reactor

2

LCL Filters for Active Front End (480V)

Line Reactor for
Non-Regenerative
Front End (480/575VV)

Amps

Catalog Number

Amps

Catalog Number

2

10

REG 10 5 0

270

REG 270 5 0

2

18

REG 18 5 0

410

REG 410 5 0

32

REG 32 5 0

580

REG 580 5 0

2

48

REG 48 5 0

840

REG 840 5 0

75

REG 75 5 0

1160

REG 1160 5 0

2

110

REG 110 5 0

1480

REG 1480 5 0

180

REG 180 5 0

2
2
2

Amps

Watts
Losses

Catalog
Number

600

493

CHK600

LCL Filters for Active Front End (690V)
Amps

Catalog Number

Amps

Catalog Number

2

14

REG 14 6 0

287

REG 287 6 0

23

REG 23 6 0

390

REG 390 6 0

2

35

REG 35 6 0

460

REG 460 6 0

52

REG 52 6 0

620

REG 620 6 0

2

85

REG 85 6 0

780

REG 780 6 0

2

122

REG 122 6 0

920

REG 920 6 0

185

REG 185 6 0

1180

REG 1180 6 0

2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
V6-T2-286

Volume 6—Solid-State Motor Control CA08100007E—May 2014 www.eaton.com

2.10

Adjustable Frequency Drives
SPA9000/SPN9000/SPI9000 Common DC Bus Drives

Options

2

9000X Series Option Board Kits

2

The 9000X Series drives can accommodate a wide selection of expander and adapter option boards to
customize the drive for your application needs. The drive’s control unit is designed to accept a total of
five option boards.
The 9000X Series factory installed standard board configuration includes an A9 I/O board and an A2
relay output board, which are installed in slots A and B.
Option Boards

2
2
2

Option Board Kits

Allowed Slot
Locations 2

Field
Installed
Catalog
Number

Factory
Installed
Option
Designator

SVX Ready Programs
Local/
Basic Remote Standard

MSS

PID

Multi-P. PFC

2 RO (NC-NO)

B

OPTA2

—

■

■

■

■

■

■

■

6 DI, 1 DO, 2 AI, 1AO, 1 +10 Vdc ref,
2 ext +24 Vdc/EXT +24 Vdc

A

OPTA9

—

■

■

■

■

■

■

■

2 RO, therm

B

OPTA3

A3

—

■

■

■

■

■

■

Encoder low volt +5V/15V24V

C

OPTA4

A4

—

■

■

■

■

■

■

Encoder high volt +15V/24V

C

OPTA5

A5

—

■

■

■

■

■

■

Option Kit Description 1
Standard I/O Cards
A

D E
B C

2
2
2
2

Extended I/O Cards

2
2

Double encoder

C

OPTA7

A7

■

■

■

■

■

■

■

6 DI, 1 DO, 2 AI, 1 AO

A

OPTA8

A8

—

■

■

■

■

■

■

3 DI (encoder 10–24V), out +15V/+24V,
2 DO (pulse+direction)

C

OPTAE

AE

■

■

■

■

■

■

■

2

6 DI, 1 ext +24 Vdc/EXT +24 Vdc

B, C, D, E

OPTB1

B1

—

—

—

—

—

■

■

2

1 RO (NC-NO), 1 RO (NO), 1 therm

B, C, D, E

OPTB2

B2

—

—

—

—

—

■

■

1 AI (mA isolated), 2 AO (mA isolated),
1 ext +24 Vdc/EXT +24 Vdc

B, C, D, E

OPTB4

B4

—

■

■

■

■

■

■

2

3 RO (NO)

B, C, D, E

OPTB5

B5

—

—

—

—

—

■

■

2

1 ext +24 Vdc/EXT +24 Vdc, 3 Pt100

B, C, D, E

OPTB8

B8

—

—

—

—

—

—

—

1 RO (NO), 5 DI 42–240 Vac input

B, C, D, E

OPTB9

B9

—

—

—

—

—

■

■

SPI, absolute encoder

C

OPTBB

BB

—

—

—

—

—

—

—

2

Modbus

D, E

OPTC2

C2

■

■

■

■

■

■

■

Johnson Controls N2

D, E

OPTC2

CA

—

—

—

—

—

—

—

2

Modbus TCP

D, E

OPTCI

CI

■

■

■

■

■

■

■

BACnet

D, E

OPTCJ

CJ

■

■

■

■

■

■

■

EtherNet/IP

D, E

OPTCQ

CQ

■

■

■

■

■

■

■

PROFIBUS DP

D, E

OPTC3

C3

■

■

■

■

■

■

■

LonWorks

D, E

OPTC4

C4

■

■

■

■

■

■

■

PROFIBUS DP (D9 connector)

D, E

OPTC5

C5

■

■

■

■

■

■

■

CANopen (slave)

D, E

OPTC6

C6

■

■

■

■

■

■

■

DeviceNet

D, E

OPTC7

C7

■

■

■

■

■

■

■

Modbus (D9 type connector)

D, E

OPTC8

C8

■

■

■

■

■

■

■

Adapter

D, E

OPTD1

D1

■

■

■

■

■

■

■

Adapter

D, E

OPTD2

D2

■

■

■

■

■

■

■

RS-232 with D9 connection

D, E

OPTD3

D3

■

■

■

■

■

■

■

2

9000X Series local/remote keypad
(replacement keypad)

—

KEYPADLOC/REM

—

—

—

—

—

—

—

■

2

9000X Series remote mount keypad unit
(keypad not included, includes 10 ft cable,
keypad holder, mounting hardware)

—

OPTRMTKIT-9000X

—

—

—

—

—

—

—

—

2

9000X Series RS-232 cable, 13 ft

—

PP00104

—

—

—

—

—

—

—

—

Communication Cards 3

Keypad

Notes
1 AI = Analog Input; AO = Analog Output, DI = Digital Input, DO = Digital Output, RO = Relay Output
2 Option card must be installed in one of the slots listed for that card. Slot indicated in bold is the preferred location.
3 OPTC2 is a multi-protocol option card.

Volume 6—Solid-State Motor Control CA08100007E—May 2014 www.eaton.com

2

2
2
2
2
2
2

2
2
2

V6-T2-287

2.10

Adjustable Frequency Drives
SPA9000/SPN9000/SPI9000 Common DC Bus Drives

2

Technical Data and Specifications

2

SPA9000/SPN9000/SPI9000

2
2
2

Description

Specification

Supply Connection
Input voltage Uin (AC) front end modules

380–500 Vac/525–690 Vac –10% to 10%

Input voltage Uin (DC) inverter

465–800 Vdc/640–1100 Vdc –0% to 0%, the waviness of the inverter supply voltage,
formed in rectification of the electric network’s alternating voltage in basic frequency,
must be less than 50V peak-to-peak

Output voltage Uout (AC) inverter

3 ~ 0–Uin/1.4

Output voltage Uout (DC) active front end module

10.10 x 1.35 x Uin (factory default)

2

Output voltage Uout (DC) non-regenerative front end module

1.35 x Uin

2

Ambient operating temperature

14 (no frost) to 122°F (–10 to 50°C): IH
14 (no frost) to 104°F (–10 to 40°C): IL

2

Storage temperature

–40 to 158°F (–40 to 70°C)

Relative humidity

0 to 95% RH, non-condensing, non-corrosive, no dripping water

2

2
2
2
2
2
2
2
2

Ambient Conditions

Air quality
Chemical vapors

IEC 721-3-3, unit in operation, class 3C2

Mechanical particles

IEC 721-3-3, unit in operation, class 3S2

Altitude

100% load capacity (no derating) up to 1000m
1% derating for each 100m above 1000m; max. 3000m

Vibration

5–150 Hz

EN50178/EN60068-2-6

Displacement amplitude 0.25 mm (peak) at 3–15.8 Hz
Max acceleration amplitude 1G at 15.8–150 Hz

Shock
EN50178, EN60068-2-27

UPS Drop Test (for applicable UPS weights)
Storage and shipping: max 15G, 11 ms (in package)

Cooling capacity required

Approximately 2%

Cooling air required

FR4 41 cfm, FR6 250 cfm, FR7 250 cfm, FR8 383 cfm
FI9 677 cfm, FI10 824 cfm, FI12 1648 cfm, FI13 2472 cfm

Unit enclosure class

FR4–FR7 NEMA Type 1/IP21; FR8, FI9–FI14 chassis (IP00)

EMC (at fault settings)

2

Immunity

2

Approvals

Fulfill all EMC immunity requirements

Safety
CE, UL, cUL, EN 61800-5-1 (2003), see unit nameplate for more detailed approvals

Control Connections

2

Analog input voltage

0–10V, Ri = 200 kohms, (–10V to 10V joystick control)
Resolution 0.1%, accuracy ±1%

2

Analog input current

0(4)–20 mA, Ri = 250 ohms differential

2

Digital inputs

6, positive or negative logic; 18–30 Vdc

Auxiliary voltage

+24V, ±15%, max. 250 mA

Output reference voltage

+10V, +3%, max. load 10 mA

Analog output

0(4)–20 mA; RL max. 500 ohms; resolution 10 bits
Accuracy ±2%

2
2
2

Digital outputs

Open collector output, 50 mA/48V

Relay outputs

2 programmable change-over relay outputs
Switching capacity: 24 Vdc/8A, 250 Vac/8A, 125 Vdc/0.4A
Min. switching load: 5V/10 mA

2
2
2
2
2
V6-T2-288

Volume 6—Solid-State Motor Control CA08100007E—May 2014 www.eaton.com

Adjustable Frequency Drives
SPA9000/SPN9000/SPI9000 Common DC Bus Drives

2.10

SPA9000/SPN9000/SPI9000, continued
Description

2

Specification

2

Protections
Overvoltage protection

480V/911 Vdc, 575V/1200 Vdc

Undervoltage protection

480V/333 Vdc, 575V/460 Vdc

Ground fault protection

In case of ground fault in motor or motor cable, only the inverter is protected

Motor phase supervision

Trips if any of the output phases is missing

Overcurrent protection

Yes

Unit overtemperature protection

Yes

Motor overload protection

Yes

Motor stall protection

Yes

Motor underload protection

Yes

Short-circuit protection of 24V and 10V reference voltages

Yes

2
2
2
2
2
2
2

Input Fuses

2

SHT fuses can be assembled into same-size DIN fuse base.
SPA9000/SPN9000/SPI9000
Module
Component

Frame

Bussman Fuse Type (aR)

Size

UN (V)

IN (A)

Qty.

SPI003A1-4

FR4

170M1560

0

690

20

2

SPI007A1-4

FR4

170M1562

0

690

63

2

SPI009A1-4

FR4

170M1562

0

690

63

2

SPI012A1-4

FR6

170M1565

0

690

63

2

SPI016A1-4

FR6

170M1565

0

690

63

2

SPI023A1-4

FR6

170M1565

0

690

63

2

SPI031A1-4

FR6

170M1567

0

690

100

2

SPI038A1-4

FR6

170M1567

0

690

100

2

SPI061A1-4

FR7

170M1570

0

690

200

2

SPI072A1-4

FR7

170M1570

0

690

200

2

SPI087A1-4

FR7

170M1571

0

690

250

2

SPI105A0-4

FR8

170M3819

DIN1

690

400

2

SPI140A0-4

FR8

170M3819

DIN1

690

400

2

SPI170A0-4

FR8

170M3819

DIN1

690

400

2

SPI205A0-4

FI9

170M6812

DIN3

690

800

2

SPI245A0-4

FI9

170M6812

DIN3

690

800

2

SPI300A0-4

FI10

170M8547

3SHT

690

1250

2

SPI385A0-4

FI10

170M8547

3SHT

690

1250

2

SPI460A0-4

FI10

170M8547

3SHT

690

1250

2

SPI520A0-4

FI12

170M8547

3SHT

690

1250

2x2

SPI590A0-4

FI12

170M8547

3SHT

690

1250

2x2

SPI650A0-4

FI12

170M8547

3SHT

690

1250

2x2

SPI730A0-4

FI12

170M8547

3SHT

690

1250

2x2

SPI820A0-4

FI12

170M8547

3SHT

690

1250

2x2

SPI920A0-4

FI12

170M8547

3SHT

690

1250

2x2

SPIH10A0-4

FI13

170M8547

3SHT

690

1250

6

SPIH11A0-4

FI13

170M8547

3SHT

690

1250

6

SPIH13A0-4

FI13

170M8547

3SHT

690

1250

6

SPIH16A0-4

FI14

170M8547

3SHT

690

1250

2x6

SPIH19A0-4

FI14

170M8547

3SHT

690

1250

2x6

SPIH23A0-4

FI14

170M8547

3SHT

690

1250

2x6

2
2

Inverter Units

Volume 6—Solid-State Motor Control CA08100007E—May 2014 www.eaton.com

2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
V6-T2-289

2.10
2
2
2

Adjustable Frequency Drives
SPA9000/SPN9000/SPI9000 Common DC Bus Drives

SHT fuses can be assembled into same-size DIN fuse base.
SPA9000/SPN9000/SPI9000, continued
Module
Component

Frame

Bussman Fuse Type (aR)

Size

UN (V)

IN (A)

Qty.

Active Front Ends

2

SPA205A0-4

FI9

170M6202

3SHT

1250

500

3

SPA385A0-4

FI10

170M6277

3SHT

1250

1000

3

2

SPAH10A0-4

FI13

170M6277

3SHT

1250

1000

3x3

170M8547

3SHT

690

1250

3

2
2
2
2
2

Non-Regenerative Front Ends
SPN468A0-4

FI9

Wiring Diagrams
SPA9000—
Active Front End

SPN9000—NonRegenerative Front End

380 – 500 Vac

380 – 500 Vac

L1
L2
L3

2

-K4

2

NFE
-F1

SPI9000—Inverter Unit
(FI9–FI14)

425 – 800 Vdc

425 – 800 Vdc

DC+
DC-

L1
L2
L3

AFE -F1

2

SPI9000—Inverter Unit
(FR4–FR8)

DC+
DC-

INU DC+
-F1

DC-

INU DC+
-F1

DC-

-F4

-L1.1

2

-K5
-V4

-L1.2

-L1

2

-R4
-U1

-U1

2
2

PE U V

2
2

-F2

-F2

425 – 600 Vdc

425 – 800 Vdc

DC+
DC-

DC+
DC-

2
2
2
2
2
2
2
2
2
2
2
V6-T2-290

Volume 6—Solid-State Motor Control CA08100007E—May 2014 www.eaton.com

M

W

PE U V

M

W

Adjustable Frequency Drives
SPA9000/SPN9000/SPI9000 Common DC Bus Drives

2.10

Dimensions

2

Approximate Dimensions in Inches (mm)

2

SPA9000/SPN9000/SPI9000
Frame

Height

Width

Depth

Weight
Lbs (kg)

9.4 (239)

14.6 (372)

148 (67)

2

Active Front Ends
FI9

40.6 (1030)

2
2

FI10

40.6 (1032)

9.4 (239)

21.7 (552)

220 (100)

FI12

40.6 (1032)

2 x 9.4 (2 x 239)

21.7 (552)

441 (200)

FI13

40.6 (1032)

27.9 (708)

21.8 (553)

674 (306)

FI14

40.6 (1032)

2 x 27.9 (2 x 708)

21.8 (553)

1348 (612)

9.4 (239)

14.6 (372)

148 (67)

2
2

2
2

Non-Regenerative Front Ends
FI9

40.6 (1030)

Inverter Units
FR4

11.5 (292)

5.0 (128)

7.5 (190)

11 (5)

FR6

20.4 (519)

7.7 (195)

9.3 (237)

35 (16)

FR7

23.3 (591)

9.3 (237)

10.1 (257)

64 (29)

FR8

29.8 (758)

11.4 (289)

13.5 (344)

106 (48)

FI9

40.6 (1030)

9.4 (239)

14.6 (372)

148 (67)

FI10

40.6 (1032)

9.4 (239)

21.7 (552)

220 (100)

FI12

40.6 (1032)

2 x 9.4 (2 x 239)

21.7 (552)

441 (200)

FI13

40.6 (1032)

27.9 (708)

21.8 (553)

674 (306)

FI14

40.6 (1032)

2 x 27.9 (2 x 708)

21.8 (553)

1348 (612)

2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2

Volume 6—Solid-State Motor Control CA08100007E—May 2014 www.eaton.com

V6-T2-291



Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.6
Linearized                      : Yes
Author                          : Zoltun Design
Create Date                     : 2014:05:29 11:21:59-05:00
Modify Date                     : 2014:05:29 12:29:01-05:00
Subject                         : Adjustable Frequency Drives
XMP Toolkit                     : Adobe XMP Core 4.2.1-c043 52.372728, 2009/01/18-15:56:37
Creator Tool                    : PScript5.dll Version 5.2.2
Metadata Date                   : 2014:05:29 12:29:01-05:00
Format                          : application/pdf
Title                           : Volume 6 Tab 2
Creator                         : Zoltun Design
Description                     : Adjustable Frequency Drives
Producer                        : Acrobat Distiller 9.5.5 (Macintosh)
Document ID                     : uuid:2722eaf2-f55b-6542-afa9-53b5d8e0b92d
Instance ID                     : uuid:dd9e97a3-a1dc-2841-8887-83ffe2c87dc3
Page Count                      : 291
EXIF Metadata provided by EXIF.tools

Navigation menu