Product Detail Manual
113610-Catalog 113610-Catalog 113610-Catalog 785901 Batch12 unilog cesco-content
2014-11-11
: Pdf 54531-Attachment 54531-Attachment 785901 Batch12 unilog
Open the PDF directly: View PDF .
Page Count: 24
Download | ![]() |
Open PDF In Browser | View PDF |
Table of Contents Section 3 Safety Switches Light Duty Fusible 3-2 Application Data and Dimensions 3-3 Standards: • • UL 98 Enclosed and Dead Front Switches. UL Listed under File E2875. NEMA Standards Publication KS1. Enclosed Switches. General Duty Light Duty, p. 3-2 Fusible and Non-Fusible 3-2 Application Data and Dimensions 3-3 Standards: • • UL 98 Enclosed and Dead Front Switches. UL Listed under File E2875. NEMA Standards Publication KS1. Enclosed Switches. Heavy Duty Fusible 3-4 Non-Fusible 3-6 Special Application Enclosures 3-7 Motor Disconnect and Receptacle Switches General Duty, p. 3-2 3-8 Accessories 3-11 Application Data and Dimensions 3-13 Standards: • • • UL 98 Enclosed and Dead Front Switches. UL Listed under files E2875, E154828, E233505 and E317818. UL 508 Industrial Control Equipment, file E 164864. NEMA Standards Publication KS1 Enclosed Switches (UL98 Switches Only). Fusible and Non-Fusible 3-15 Accessories 3-18 Standards: • • Heavy Duty, p. 3-4 UL 98 Enclosed and Dead Front Switches. UL Listed under files E2875 (unless otherwise noted). NEMA Standards Publication KS1 Enclosed Switches (applies to Type DT and DTU series F only). Application Data and Dimensions 1000 Vdc Photovoltaic Heavy Duty Disconnect Switch 3-19 3-22 3 Standards: • • • • • • UL 98 Enclosed and Dead Front Switches UL Listed under file E343347 IEC 60947 - 1 Electrical IEC 60947 - 3 Mechanical NEMA standard. Publication KS-1 Enclosed Switches IP 63 and NEMA 3 Enclosure Stainless Steel Heavy Duty, p. 3-7 © 2012 Schneider Electric All Rights Reserved SAFETY SWITCHES Double Throw 3-1 General Duty Safety Switches Light Duty Class 3130 / Refer to Catalog 3100CT0901 www.schneider-electric.us Light Duty—Visible Blades 10 kA Short Circuit Current Rating The Square D light duty enclosed switch is ideal for home applications in disconnecting power to workshops, hobby rooms, furnaces, and garages. Table 3.1: System L221N Fusible Amperes Fuse NEMA 1 Indoor Cat. No. $ Price 2 Wire (1 Blade and Fuseholder, 1 Neutral)—120 Vac 30 a Plug L111N Horsepower Ratings Std. Max. 1/2 2 $54.00 System NEMA 1 Indoor Amperes Fuse Horsepower Ratings Cat. No. $ Price Std. 3 Wire (2 Blades and Fuseholders, 1 Neutral)—120/240 Vac Max. 30 Plug L211N 72.00 1-1/2a 3a 30 Cart. L221N 98.00 1-1/2a 3a For single phase hp rating, use two switching poles. General Duty—Up To 100 kA Short Circuit Current Rating With Proper Current Limiting Fusing General duty safety switches are designed for residential and commercial applications where durability and economy are prime considerations. Typical loads are lighting, air conditioning, and appliances. They are suitable for use as service equipment when equipped with a factory- or field-installed neutral assembly or a field-installed service grounding kit, (see Table 3.6) as applicable. General duty safety switches are UL Listed, File E2875, and meet or exceed the NEMA Standard KS1. D223N Table 3.2: Fusible UL Listed Short Circuit Withstand Rating Short Circuit Rating Plug 10 kA H 10 kA K 10 kA Fusible J 100 kA R 100 kA T 100 kA H 10 kA K 10 kA NonJ 100 kA Fusiblea R 100 kAb T 100 kA a The UL Listed short-circuit current rating for Square D general duty, not fusible switches is based on the switch being used in conjunction with fuses. Evaluation of nonfusible switches in conjunction with molded case circuit breakers above 10,000 amps has not been performed. For applications requiring greater protection, consider using a heavy duty safety switch. Refer to UL Listed Maximum Short Circuit Current Ratings—AC only—on page 3-6. If a UL Listed short-circuit current rating is required, this nonfusible switch must be replaced with a Square D general duty fusible safety switch equipped with the appropriate class and size fusing. Consult the wiring diagram of the switch to verify the UL Listed shortcircuit current rating. b 50 kA for 60 A non-fusible switch. Switch Type 3 SAFETY SWITCHES 3-2 Fuse Class NEMA 1 Indoor System Amperes NEMA 3Ra Rainproof Class R Fuse Kits Field-Installedb Fuse Cat. No. $ Price Cat. No. $ Price Cat. No. $ Price 2 Wire (1 Blade and Fuseholder, 1 Neutral)—120 Vac 30 Plug Use Light Duty Device for this Application (see below) 30 Cart. Use three-wire devices for this application. Horsepower Ratings Std. (Fast Acting One-Time Fuses) Max. (Dual Element Time-Delay Fuses) 1Ø 3Ø 1Ø 3Ø — — — — — — — — 3 Wire (2 Blades and Fuseholders, 1 Neutral)—120/240 Vac (Plug), 240 Vac (Cart.) Maximum 30 Plug D211N 90.00 D211NRB 177.00 — — 1-1/2 — 3 — 30 Cart. D221N 122.00 D221NRB 188.00 DRK30 25.65 1-1/2 3c 3 7-1/2c 60 Cart. D222N 206.00 D222NRB 326.00 RFK03H 25.50 3 7-1/2c 10 15c 100 Cart. D223N 426.00 D223NRB 480.00 RFK10 47.70 7-1/2 15 c 15 30c 200 Cart. D224Ne 884.00 D224NRBe 1200.00 HRK1020 47.70 15 25 c — 60c 400 Cart. D225N 2555.00 D225NR 3459.00 DRK40 111.00 — — — — 600g Cart. D226N 5109.00 D226NR 6569.00 DRK600 111.00 — — — — 4 Wire (3 Blades and Fuseholders, 1 Neutral)—240 Vac Maximum 30 Cart. D321N 188.00 D321NRB 293.00 DRK30 25.65 1-1/2 3 3 7-1/2 60 Cart. D322N 326.00 D322NRB 441.00 RFK03H 25.50 3 7-1/2d 10 15d 100 Cart. D323N 564.00 D323NRB 816.00 RFK10 47.70 7-1/2 15d 15 30d 200 Cart. D324Ne 1202.00 D324NRBe 1461.00 HRK1020 47.70 15 25d — 60d 400 Cart. D325N 3113.00 D325NR 3893.00 DRK40 111.00 — 50 — 125 400f Class T D325NT 2994.00 D325NTR 3741.00 — — — 50 — — 600g Cart. D326N 5823.00 D326NR 7877.00 DRK600 111.00 — 75 — 150 600f Class T D326NT 5598.00 D326NTR 7569.00 — — — 75 — — 800f Class T T327N 9722.00 T327NR 12438.00 — — — 100 — — a Bolt-on hubs—Refer to page 3-10. b When installed, this kit rejects all but Class R fuses. c For corner grounded delta systems only. Use switching poles for ungrounded conductors. See data bulletin 2700DB0202 for additional information. d If corner grounded delta, use outer switching poles for ungrounded conductors. e For 200% neutral, order (1) additional neutral kit SN20A and (1) neutral jumper kit SN20NI. f Class T 400–800 A general duty safety switches use 300 Vac Class T fuses and are UL Listed for use on systems with up to 100 kA available fault current. g Order Class J fuse kit: GDJK600 for Class J fuses. Table 3.3: System Non-Fusible Amperes NEMA 3R Rainproof h NEMA 1 Indoor Cat. No. $ Price Cat. No. $ Price Horsepower Ratings (Max.) 1Ø 3Ø 2 Wire (2 Blades)—240 Vac Maximum 30 — — DU221RB 177.00 3 — 60 — — DU222RB 353.00 10 — 60 QO260NATSij 161.00 QO200TR ijk 161.00 10 — 100 QO2000NSij 276.00 QO2000NRBik 338.00 20 — 200 Use 3P Switch — Use 3P Switch — — — 400p Use 3P Switch — Use 3P Switch — — — 600 Use 3P Switch — Use 3P Switch — — — 3 Wire (3 Blades)—240 Vac Maximum 30 DU321 155.00 DU321RB 293.00 3 7-1/2 60 DU322 206.00 DU322RB 443.00 10 15 100 DU323l 477.00 DU323RBl 816.00 15 30 200 DU324m 884.00 DU324RBm 1461.00 15 60n 400p DU325 2198.00 — — — 125 600 DU326n 4191.00 — — — 150 h Bolt-on hubs—Refer to page 3-10. i Enclosed molded case switch—Refer to page 1-24. j Includes factory-installed grounding kit. k Not service entrance rated—Refer to page 1-19 for more information. l If a neutral assembly is required, order and field-install SN0610. m If a neutral assembly is required, order and field install a SN20A Neutral Assembly Kit. For a 200% neutral application, order and field install (2) SN20A Neutral Assembly Kits and (1) SN20NI Neutral Jumper Kit. n If a neutral assembly is required, order part number D600SN. Available for field-installation. o For single phase hp rating, use two switching poles. p To accept J class fuses, move fuse bases to the embossed guide inside of the switch. DE1A DE2A Discount Schedule © 2012 Schneider Electric All Rights Reserved General Duty Safety Switches Accessories, Lug Data and Dimensions Class 3130 / Refer to Catalog 3100CT0901 www.schneider-electric.us Terminal Lug Data a Table 3.4: Table 3.6: Wire Range Amperes Conductors Per NEC Table 312.6 Per Phase Wire Bending Space AWG/kcmil 30 60 100 200 1 1 1 1 1 or 2 Lug Wire Range AWG/kcmil 12–6 (Al) or 14–6 (Cu) 10–2 (Al) or 14–2 (Cu) 12–1/0 (Al) or 14–1/0 (Cu) 6 –300 (Al/Cu) (1) 1/0 –750 (Al/Cu) 400 or NEMA 1 (2) 1/0 –300 (Al/Cu) (1) 1 –600 (Al/Cu) 400 2 1/0–250 (Al/Cu) or NEMA 3R (2) 1/0 –250 (Al/Cu) 600 2 4 –500 (Al/Cu) 4 –600 (Al/Cu) 800 3 3/0 –500 (Al/Cu) 3/0 –500 (Al/Cu) o o a 30–100 A switches suitable for 60 C or 75 C conductors. 200–800 A switches suitable for 75oC conductors. Cat. No. 30 PK3GTA1 11.40 60a PK3GTA1 11.40 60b GTK03 11.40 12–6 (Al) or 14–6 (Cu) 10–3 (Al) or 14–3 (Cu) 12–1 (Al) or 14–1 (Cu) 6 –250 (Al/Cu) 1/0 –600 (Al/Cu) or 1/0 –300 (Al/Cu) a b NOTE: Field-installed lug kits are located in the Supplemental Digest page 2.2. Kit consists of three fuse pullers as required for a 3P, fusible, 60 and 100 A general duty switch. Kits can be installed in 60 and 100 A Series F switches. Table 3.5: Fuse Puller Kits Description Cat. No. FPK03 FPK0610 100 GTK0610 200 PKOGTA2 400 PKOGTA2 600 (Two Required) 800 PKOGTA3 Series E switch only. Series F switch only. $ Price 18.90 55.00 55.00 123.00 Wire Size (AWG) (2) 12 Cu or (2) 10 Al or (1) 4 Al/Cu Max. (2) 12 Cu or (2) 10 Al or (1) 4 Al/Cu Max. (2) 12 Cu or (2) 10 Al or (1) 4 Al/Cu Max. (2) 1/0 Al/Cu Max. (2) 2/0 Al/Cu Max. (2) 2/0 Al/Cu Max. Per Lug (6) 3/0 Al/Cu Max. Field-Installed Electrical Interlock Kits Field-Installed Fuse Puller Kits Series F 60 A Fuse Puller Kit Series F 100 A Fuse Puller Kit Field-Installed Service Grounding Kits Amperes $ Price 30.00 42.60 W Electrical interlocks for Series F 100–200 A general duty safety switches and Series F 60 A fusible general duty safety switches are available in kit form for field installation. Each kit contains instructions for proper field mounting. A pivot arm operates from switch mechanism, breaking the control circuit before the main switch blades break. Switches with electrical interlocks installed are UL Listed. Table 3.7: Electrical Interlock Kit Switch’s Amperes Rating Electrical Interlock Kit $ Price Cat. No.a EIK031 or 60 Fb 218.00 EIK032 EIK1 or 100–200 F 311.00 EIK2 a Electrical interlock kit catalog numbers with -1 suffix indicates one normally open and one normally closed contact; -2 indicates two normally open and two normally closed contacts. Kits are UL Listed. b Fusible series. Series H W/H H W W/H D Std. Cat. No. in. mm in. mm in. mm in. mm Pack L111N E2 7.63 194 5.00 127 6.13 156 4.00 102 1 D325NTRc L211N E2 7.63 194 5.00 127 6.13 156 4.00 102 1 D326Nc L221N E2 7.63 194 5.00 127 6.13 156 4.00 102 1 D326NTc D211Nc E3 9.25 235 6.75 171 7.25 184 3.63 92 5 D326NRc D211NRBc E2 9.63 245 7.25 184 7.75 197 3.75 95 5 D326NTRc D221Nc E3 9.25 235 6.75 171 7.25 184 3.63 92 5 DU221RBc D221NRBc E3 9.63 245 7.25 184 7.75 197 3.75 95 5 DU222RBc D222N F1 14.63 372 6.50 165 7.45 189 4.88 124 1 DU321c D222NRB F1 14.88 378 6.63 168 7.45 189 4.88 124 1 DU321RBc D223N F3 17.50 445 8.50 216 10.50 267 6.50 165 1 DU322c D223NRB F3 17.50 445 8.50 216 10.50 267 6.50 165 1 DU322RBc D224N F1 29.00 737 17.25 438 19.00 483 8.25 210 1 DU323 D224NRB F1 29.25 743 17.25 438 19.00 483 8.25 210 1 DU323RB D225N E3 45.12 1146 24.00 610 24.88 632 8.88 226 1 DU324 D225NR E1 30.63 778 21.38 543 22.25 565 10.13 257 1 DU324RB D226Nc E3 49.13 1248 24.00 610 24.88 632 8.88 226 1 DU325c D226NRc E1 49.13 1248 24.75 629 25.13 638 8.88 226 1 DU326c D321Nc E3 9.25 235 6.75 171 7.25 184 3.63 92 5 QO200TRc D321NRBc E3 9.63 245 7.25 184 7.75 197 3.75 95 5 QO260NATSc D322N F1 14.63 372 6.50 165 7.45 189 4.88 124 1 QO2000NRBc D322NRB F1 14.88 378 6.63 168 7.45 189 4.88 124 1 QO2000NSc D323N F3 17.50 445 8.50 216 10.50 267 6.50 165 1 T327Nc D323NRB F3 17.50 445 8.50 216 10.50 267 6.50 165 1 T327NRc D324N F1 29.00 737 17.25 438 19.00 483 8.25 210 1 D324NRB F1 29.25 743 17.25 438 19.00 483 8.25 210 1 D325Nc E3 45.12 1146 24.00 610 24.88 632 8.88 226 1 D325NTc E3 45.12 1146 24.00 610 24.88 632 8.88 226 1 D325NRc E1 30.63 778 21.38 543 22.25 565 10.13 257 1 c 30–100 A switches suitable for 60oC or 75oC conductors. 200–800 A switches suitable for 75oC conductors. Cat. No. Series © 2012 Schneider Electric All Rights Reserved DE1 DE3A Discount Schedule Series E1 E3 E3 E1 E1 E2 E1 E2 E2 E1 E1 F3 F3 F1 F1 E3 E3 G3 E2 E1 E1 E1 E1 H in. 30.63 49.13 49.13 49.13 49.13 9.63 9.63 9.25 9.63 9.25 9.63 17.50 17.50 29.00 29.25 45.12 49.13 6.50 9.25 14.00 13.38 49.13 49.13 mm 778 1248 1248 1248 1246 245 245 235 245 235 245 445 445 737 743 1146 1248 165 235 356 340 1248 1248 W W/H D Std. in. mm in. mm in. mm Pack 21.38 543 22.25 565 10.13 257 1 24.00 610 24.88 632 8.88 226 1 24.00 610 24.88 632 8.88 226 1 24.75 629 25.13 638 8.88 226 1 24.75 629 25.13 638 8.88 226 1 7.25 184 7.75 197 3.75 95 5 7.25 184 7.75 197 3.75 95 5 6.75 171 7.25 184 3.63 92 5 7.25 184 7.75 197 3.75 95 5 6.75 171 7.25 184 3.63 92 5 7.25 184 7.75 197 3.75 95 5 8.50 216 10.50 267 6.50 165 1 8.50 216 10.50 267 6.50 165 1 17.25 438 19.00 483 8.25 210 1 17.25 438 19.00 483 8.25 210 1 24.00 610 24.88 632 8.88 226 1 24.00 610 24.88 632 8.88 226 1 4.63 118 — — 3.88 99 5 4.88 124 — — 3.25 83 1 7.75 197 — — 4.50 114 1 6.13 156 — — 3.50 89 1 24.00 610 24.88 632 8.88 226 1 24.75 629 25.13 638 8.88 226 1 3-3 SAFETY SWITCHES Approximate Dimensions 3 Table 3.8: D Heavy Duty Safety Switches 240 Volt Class 3110 / Refer to Catalog 3100CT0901 www.schneider-electric.us Visible blade heavy duty safety switches are designed for application where maximum performance and continuity of service are required. All heavy duty safety switches feature quick-make, quick-break operating mechanism, a dual cover interlock and a color coded indicator handle. They are suitable for use as service equipment when equipped with a field- or factory-installed neutral assembly or equipment grounding kit, unless a 600Y/347 V or 480 Y/277 V, 1000 A or greater, solidly grounded WYE system is used, per NEC 215-10. Heavy duty safety switches are UL Listed (except as noted), File E2875 and 154828 and meet or exceed the NEMA Standard KS1. For UL Listed short circuit current ratings, see page 3-6. NEMA 3R NEMA 4, 4X and 5 Stainless Steel NEMA 1 Table 3.9: System NEMA 12 240 Volt—Single Throw Fusible Amperes NEMA 1 Indoor Cat. No. $ Price NEMA 3R Rainproof (Bolt-on Hubs, page 3-10) Cat. No. $ Price NEMA 4, 4X, 5, a 304 Stainless Steel (for 316 stainless, see page 3-7) Dust tight, Watertight, Corrosion Resistant (Watertight Hubs, page 3-10) Cat. No. $ Price NEMA 12K With Knockouts (Watertight Hubs, page 3-10) Cat. No. $ Price NEMA 12, 3R b Without Knockouts (Watertight Hubs, page 3-10) Cat. No. 3 SAFETY SWITCHES 2-Wire (2 Blades and Fuseholders)—240 Vac, 250 Vdc 30 H221DS 1947.00 H221A 504.00 H221AWK 30 — — — — H2212AWKe Use three-wire devices 60 H222DS 2337.00 — — H222AWK For two-wire applications 100 H223DS 5094.00 H223A 1008.00 H223AWK 200 H224DS 6960.00 H224A 1737.00 H224AWK 400 H225 2729.00 H225R 3884.00 H225DS 14481.00 — — H225AWK 600 H226 5424.00 H226R 7281.00 H226DS 20772.00 — — H226AWK 800 H227 8459.00 H227Rf 11483.00 — — — — H227AWK — — — — H228AWK 1200 H228 11682.00 H228Rf 15486.00 3-Wire (2 Blades and Fuseholders, 1 Neutral)—240 Vac, 250 Vdc 30 H221N 236.00 H221NRB 447.00 Use two-wire devices, 60 H222N 471.00 H222NRB 842.00 Field-installed solid neutral assemblies 100 H223N 716.00 H223NRB 1086.00 Order separately See page 3-11. 200 H224N 1289.00 H224NRB 1562.00 400 H225N 3092.00 H225NR 4245.00 H225NDS 14787.00 — — H225NAWK 600 H226N 5819.00 H226NR 7677.00 H226NDS 21081.00 — — H226NAWK 800 H227N 10067.00 H227NRf 12216.00 — — — — H227NAWK 1200 H228N 12422.00 H228NRf 16665.00 — — — — H228NAWK 3-Wire (3 Blades and Fuseholders)—240 Vac, 250 Vdc 30 H321DS 2049.00 H321A 639.00 H321AWK 60 H322DS 2532.00 H322A 914.00 H322AWK Use four-wire devices For three-wire applications 100 H323DS 5346.00 H323A 1412.00 H323AWK 200 H324DS 7496.00 H324A 2040.00 H324AWK 400 H325 3425.00 H325R 3975.00 H325DS 14961.00 — — H325AWK 600 H326 6170.00 H326R 8286.00 H326DS 21399.00 — — H326AWK 800 H327 11456.00 H327Rf 14849.00 — — — — H327AWK 1200 H328 14517.00 H328Rf 18728.00 — — — — H328AWK 4-Wire (3 Blades and Fuseholders, 1 Neutral)—240 Vac, 250 Vdc 30 H321N 314.00 H321NRB 555.00 Use three-wire devices, 60 H322N 528.00 H322NRB 891.00 Field-installed solid neutral assemblies 100 H323N 842.00 H323NRB 1278.00 Order separately. See page 3-11 200 H324N 1451.00 H324NRB 1748.00 400 H325N 3788.00 H325NR 4322.00 H325NDS 15321.00 — — H325NAWK 600 H326N 6519.00 H326NR 8622.00 H326NDS 21759.00 — — H326NAWK 800 H327N 12189.00 H327NRf 15563.00 — — — — H327NAWK 1200 H328N 15314.00 H328NRf 19709.00 — — — — H328NAWK 4-Wire (4 Blades and Fuseholders) 30 60 100 Use 600 Vac devices. See page 3-5. 200 400 600 a Complete rating is NEMA 3, 3R, 4, 4X, 5 and 12. For NEMA 3R applications, remove drain screw from bottom endwall. b Also suitable for NEMA 3R application by removing drain screw from bottom endwall. c For switching dc, use two outside switching poles. d For corner grounded delta systems only and with neutral assembly installed. Use switching poles for ungrounded conductors. e 60 ampere switch with 30 ampere fuse spacing and clips. Must use 60 A enclosure accessories including electrical interlocks. f Suitable for NEMA 5 applications with drain screw installed. Horsepower Ratings 240 Vac Std. (Using Fast Acting, One Time Fuses) Max. (Using Dual Element, Time 250 Vdcc Delay Fuses) $ Price 1Ø 3Ø 1Ø 3Ø 473.00 588.00 647.00 948.00 1643.00 4163.00 6543.00 10325.00 15815.00 1-1/2 1-1/2 3 7-1/2 15 — — 50 50 3d — 7-1/2 d 15 d 25 d — 75 d — — 3 3 10 15 — — — 50 50 7-1/2d — 15 d 30 d 60 d — 200 d — — 5 5 10 20 40 50 50 50 50 4304.00 6936.00 12338.00 17184.00 1-1/2 3 7-1/2 15 — — 50 50 3 d 7-1/2 d 15 d 25 d 50 d 75 d — — 3 10 15 — — — 50 50 7-1/2 d 15 d 30 d 60 d 125 d 200 d — — 5 10 20 40 50 50 50 50 639.00 864.00 1331.00 1926.00 4253.00 7365.00 14528.00 17450.00 1-1/2 3 7-1/2 15 — — 50 50 3 7-1/2 15 25 50 75 100 100 3 10 15 — — — 50 50 7-1/2 15 30 60 125 200 250 250 5 10 20 40 50 50 50 50 4635.00 7757.00 15879.00 20015.00 1-1/2 3 7-1/2 15 — — 50 50 3 7-1/2 15 25 50 75 100 100 3 10 15 — — — 50 50 7-1/2 15 30 60 125 200 250 250 5 10 20 40 50 50 50 50 Accessories: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . pages 3-10 through 3-12 Dimensions: NEMA 1 and 3R . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 3-13 Dimensions: NEMA 4, 4X and 5 Stainless and NEMA 12 . . . . . . . page 3-14 3-4 DE1 Discount Schedule © 2012 Schneider Electric All Rights Reserved Heavy Duty Safety Switches 600 Volt Class 3110 / Refer to Catalog 3100CT0901 www.schneider-electric.us Table 3.10: 600 Volts—Single Throw Fusible Horsepower Ratings System NEMA 1 Indoor Amperes Cat. No. $ Price NEMA 3R Rainproof (Bolt-on Hubs, page 3-10) Cat. No. $ Price NEMA 4, 4X, 5a 304 Stainless Steel NEMA 12K (for 316 stainless, see With Knockouts page 3-7) Dust tight, (Watertight Hubs, Watertight, Corrosion page 3-10) Resistant (Watertight Hubs, page 3-10) Cat. No. $ Price Cat. No. $ Price 480 Vac NEMA 12, 3Rb Without Knockouts (Watertight Hubs, page 3-10) Cat. No. 600 Vac Max. Std. Max. Std. (Using (Using (Using (Using Dual Fast Dual Fast Acting, Element, Acting, Element, Time One Time One Time Delay Time Delay Fuses) Fuses) Fuses) Fuses) dcd $ Price 3Ø 3Ø 3Ø 3Ø 250 600 5025.00 7341.00 15276.00 18044.00 — — — — 100 c 150 c — — — — — — 250 c 400 c — — — — — — — — — — — — — — — — — — — — — — 50 50 50 50 — — — — 50 50 50 50 5 5 15 25 50 100 150 200 200 15 15 30 60 125 250 400 500 500 7-1/2 7-1/2 15 30 60 125 200 250 250 20 20 50 75 150 350 500 500 500 5 — — — 40 50 50 50 50 15 15 30 50 50 50 50 50 50 5 15 25 50 100 150 200 200 15 30 60 125 250 400 500 500 7-1/2 15 30 60 125 200 250 250 20 50 75 150 350 500 500 500 — — — 40 50 50 50 50 15 30 50 50 50 50 50 50 2Ø 7-1/2 15 25 50 100 150 3Ø 25 2Ø 20 40 50 — 250 400 3Ø 60 2Ø 10 20 30 50 125 200 3Ø 30 2Ø 25 50 75 — 350 500 3Ø 75 5 10 20 40 50 50 15 30 30 50 50 50 — — 2-Wire (2 Blades and Fuseholders)—600 Vac, 600 Vdc 30 60 100 200 400 600 800 1200 Use three-wire devices for two-wire applications H265 H266 H267 H268 4206.00 6653.00 10365.00 14570.00 H265R 5424.00 H266R 10686.00 H267Rf 16385.00 H268Rf 17991.00 H265DS H266DS — — 14961.00 21399.00 — — — — — — — — — — H265AWK H266AWK H267AWK H268AWK 3-Wire (3 Blades and Fuseholders)—600 Vac, 600 Vdc d 30 30 60 100 200 400 600 800 1200 H361 H361-2f H362 H363 H364 H365 H366 H367 H368 528.00 H361RB 899.00 617.00 H3612RBe 1049.00 638.00 H362RB 1055.00 1188.00 H363RB 1644.00 1707.00 H364RB 2259.00 4551.00 H365R 5532.00 7649.00 H366R 10899.00 13319.00 H367R f 16500.00 17507.00 H368Rf 20009.00 H361DS — H362DS H363DS H364DS H365DS H366DS — — 2520.00 H361A — H361-2A e 2771.00 H362A 5493.00 H363A 7685.00 H364A 15321.00 — 21084.00 — — — — — 1014.00 H361AWK 956.00 1035.00 H3612AWKe 977.00 1047.00 H362AWK 984.00 1626.00 H363AWK 1539.00 2544.00 H364AWK 2400.00 — H365AWK 5462.00 — H366AWK 9203.00 — H367AWK 16352.00 — H368AWK 19706.00 4-Wire (3 Blades and Fuseholders, 1 Neutral)—600 Vac, 600 Vdcd H361N 617.00 H361NRB 986.00 H362N 710.00 H362NRB 1134.00 H363N 1278.00 H363NRB 1737.00 H364N 1869.00 H364NRB 2408.00 H365N 4898.00 H365NR 5765.00 H366N 8019.00 H366NR 11054.00 H367N 14043.00 H367NRf 17205.00 H368N 18114.00 H368NRf 20993.00 Use three-wire devices field-installed solid neutral assemblies. Order separately. See page 3-11. H364NDS H365NDS H366NDS — — 7871.00 15668.00 22122.00 — — H364NA — — — — 2715.00 — — — — H364NAWK 2558.00 H365NAWK 5823.00 H366NAWK 9600.00 H367NAWK 17253.00 H368NAWK 20820.00 H461DS H462DS H463DS H464DS — — 2937.00 3069.00 8345.00 12596.00 — — — — — — — — — — — — — — H461AWK H462AWK H463AWK H464AWK H465AWK — 4-Wire (4 Blades and Fuseholders)—600 Vac, 600 Vdcg 30 60 100 200 400 600 H461 H462 H463 H464 H465 H466 914.00 1065.00 1778.00 2957.00 6210.00 10104.00 — — — — — — — — — — — — 1115.00 1257.00 1932.00 3222.00 6807.00 — 6-Wire (6 Blades and Fuseholders)—600 Vac g a b c d e f g 100 — — — — H663DS 25964.00 — — H663AWK 200 — — — — H664DS 35393.00 — — H664AWK 5112.00 For applications requiring motor disconnect 12222.00 capability, use electrical interlock. Refer to page 3-10. Complete rating is NEMA 3, 3R, 4, 4X, 5 and 12. Also suitable for NEMA 3R application by removing drain screw from bottom endwall. For corner grounded delta systems only and with neutral assembly installed. Use switching poles for ungrounded conductors. For switching dc use two outside switching poles. 60 A switch with 30 A fuse spacing and clips. Must use 60 A enclosure accessories including electrical interlocks. Suitable for NEMA 5 applications with drain screw installed. Not suitable for use as service equipment. Class H Fuse Provisions: Fusible Square D 30 through 600 A heavy duty safety switches accept Class H fuses as standard. With Class H fuses installed, the switch is UL Listed for use on systems with up to 10 kA available fault current. SAFETY SWITCHES 30 60 100 200 400 600 800 1200 Fusible Square D 30–600 A heavy duty safety switches will accept Class R fuses as standard. A field-installed rejection kit is available which, when installed, rejects all but Class R fuses. With the installation of the rejection kit and Class R fuses, the switch is UL Listed for use on systems with up to 200 kA available fault current. See Class R fuse kits on page 3-10. Class J Fuse Provisions: Class R Fuse Provisions for installing Class J fuses are included in 30 through 400 A 600 Volt, and 100 through 400 A 240 Volt, fusible heavy duty safety switches. Conversion to Class J fuse spacing requires relocating the load side fuse base assembly from the standard Class H fuse location to an alternate position as marked in the enclosure. With Class J fuses installed, the switch is UL Listed for use on systems with up to 200 kA available fault current. Switches rated 600 A, 240 or 600 Volt, require the addition of an adapter kit, H600J at $456. One kit per 3P switch. Class L Fuse Provisions: Fusible 800 A and 1200 A safety switches use Class L bolt-in fuses and are rated for use on systems with up to 200 kA at 600 Vac maximum. 1200 A switches accept class L fuses from 601–1200 A, 800 A switches accept class L fuses from 601–800 A. Accessories: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .pages 3-10 through 3-12 Dimensions: NEMA 1 and 3R . . . . . . . . . . . . . . . . . . . . . . . . . . . . .page 3-13 Dimensions: NEMA 4, 4X and 5 . . . . . . . . . . . . . . . . . . . . . . . . . . .page 3-14 © 2012 Schneider Electric All Rights Reserved DE1 Discount Schedule 3-5 3 Class R Fuse Provisions: Heavy Duty Safety Switches Refer to Catalog 3100CT0901 www.schneider-electric.us Table 3.11: System 600 Volt—Single Throw Non-Fusible NEMA 1 Indoor Amperes Cat. No. $ Price 2-Wire (2 Blades)—600 Vac, 600 Vdc 30 60 100 200 400 HU265 2750.00 600 HU266 4896.00 800 HU267 7467.00 1200 HU268 10226.00 NEMA 4, 4X, 5 a 304 Stainless Steel (for 316 stainless, see page 3-7) Dust tight, Watertight Corrosion Resistant (Watertight Hubs, page 3-10) NEMA 3R Rainproof (Bolt-on Hubs, page 3-10) Cat. No. $ Price Cat. No. $ Price NEMA 12K With Knockouts (Watertight Hubs, page 3-10) Cat. No. $ Price NEMA 12, 3Rb Without Knockouts (Watertight Hubs, page 3-10) Cat. No. $ Price Use three-wire devices for two-wire applications. HU265R HU266R HU267Rd HU268Rd 3764.00 7533.00 12884.00 17393.00 HU265DS HU266DS — — 12812.00 18455.00 — — — — — — — — — — HU265AWK HU266AWK HU267AWK HU268AWK 3 SAFETY SWITCHES 3-Wire (3 Blades)—600 Vac, 600 Vdc 30 HU361 279.00 HU361RB 488.00 HU361DS 2120.00 HU361A 689.00 HU361AWK 30 HU361EIe 638.00 HU361RBEIe 846.00 HU361DSEIe 2480.00 HU361AEIe 1047.00 HU361AWKEIe 30 HU3612f 369.00 HU3612RBf 638.00 — — HU3612Af 710.00 HU3612AWKf 60 HU362 488.00 HU362RB 876.00 HU362DS 2520.00 HU362A 875.00 HU362AWK 60 — — — — HU362DSEIe 2972.00 — — — 100 HU363 783.00 HU363RB 1226.00 HU363DS 5102.00 HU363A 1265.00 HU363AWK 200 HU364 1209.00 HU364RB 1485.00 HU364DS 6960.00 HU364A 1697.00 HU364AWK 400 HU365 2804.00 HU365R 3840.00 HU365DS 14294.00 — — HU365AWK 600 HU366 4992.00 HU366R 7683.00 HU366DS 19062.00 — — HU366AWK 800 HU367 9978.00 HU367R d 13050.00 — — — — HU367AWK 1200 HU368 13421.00 HU368R d 17867.00 — — — — HU368AWK 4-Wire (4 Blades)—600 Vac, 600 Vdc j 30 HU461g 827.00 — — HU461DS 2586.00 — — HU461AWKh 60 HU462g 914.00 — — HU462DS 3027.00 — — HU462AWK 100 HU463g 1647.00 — — HU463DS 7401.00 — — HU463AWK 200 HU464g 2399.00 — — HU464DS 11244.00 — — HU464AWK 400 HU465 5201.00 — — — — — — HU465AWK 600 HU466 9072.00 — — — — — — — 6-Wire (6 Blades)—600 Vacj 30 — — — — HU661DS 11903.00 — — HU661AWKk 60 — — — — HU662DS 13254.00 — — HU662AWKk 100 — — — — HU663DS 20643.00 — — HU663AWKk 200 — — — — HU664DS 28316.00 — — HU664AWKk a Complete rating is NEMA 3, 3R, 4, 4X, 5 and 12. b Also suitable for NEMA 3R application by removing drain screw from bottom endwall. c For switching dc, use two outside switching poles. d Suitable for NEMA 5 applications with drain screw installed. e Switches with EI suffix are stocked with factory-installed electrical interlocks with one normally-open and one normally-closed contact. f Use 60 A enclosure accessories, including electrical interlocks. g No knockouts are provided. h Requires 60 A accessories. See page 3-14 for series rating.. i HU461AWK (Series F6) is rated 5 hp@250 Vdc, 10 hp@600 Vdc. j Not suitable for use as service equipment. k One enclosure for NEMA 1, 3, 3R or 12 applications. UL Listed. 3212.00 5408.00 12957.00 17522.00 647.00 1007.00 666.00 833.00 — 1194.00 1604.00 4023.00 6711.00 13097.00 17940.00 Horsepower Ratings (Max.) Volts ac 240 480 600 dcc 1Ø 3Ø 1Ø 3Ø 1Ø 3Ø 250 600 — — — — — — 50 50 — — — — — — 50 50 — — — — — — — — 915.00 1008.00 1791.00 2832.00 5672.00 — 5 5 5 10 10 20 15 — — 50 50 2Ø 10 20 30 50 — — 3357.00 3884.00 4793.00 10538.00 — — — — — — — — — — — — — — — — — — 50 — — — — — — — — — — — — — 50 50 — 50 — — — — 50 50 50 50 10 7-1/2 20 10 30 5 15 10 7-1/2 20 10 30 5 15 10 7-1/2 20 10 30 5 15 20 25 50 30 60 10 30 20 25 50 30 60 10 30 40 40 75 40 100 20 50 60 50 125 50 150 40 50 125 — 250 — 350 50 50 200 — 400 — 500 50 50 250 50 500 50 500 50 50 250 50 500 50 500 50 50 3Ø 2Ø 3Ø 2Ø 3Ø 10 20 20 25 30 10i 15i 20 40 50 50 60 10 30 40 50 75 50 75 20 30 60 50 125 50 150 40 50 125 — 250 — 350 50 50 200 — 400 — 500 50 50 3Ø 3Ø 3Ø 10 — 20 — 30 — — 20 — 50 — 60 — — 40 — 75 — 75 — — 60 — 125 — 150 — — UL Listed Maximum Short Circuit Current Ratings—AC only NOTE: Consult the wiring diagram of the switch to verify the UL Listed short circuit current rating. Table 3.12: Non-Fusible Safety Switches Fusible Safety Switches For the short circuit current rating, refer to the table below. Heavy Duty Safety Switch Type l UL Listed UL Listed Short Circuit Fuse Class Current Ratings H, K 10 kA Fusible R, J, L 200 kAl On 600 V, 200 A switches, 100,000 A max. on corner grounded delta when protected by Class J or R fuses. Any brand of circuit breaker or fuse not exceeding the ampere rating of the switch may be used in conjunction with an non-fusible safety switch when there is up to 10 kA short circuit current available (see table below). Above 10 kA—When applied on systems with greater than 10 kA short circuit current available, the UL Listed short circuit current rating for Square D non-fusible switches is based upon the switch being used in conjunction with fuses or Square D circuit breakers or Mag-Gard motor circuit protectors. Table 3.13: Non-Fusible Safety Switches Heavy Duty Switch Rating Safety Switch Type (A) m Fuse or Circuit Breaker Typen 3-Phase 480 Vac 600 Vac Any brand circuit breaker Up to 10 kA All H, K R,T,J.L 200 kA 200 kA 200 kA 30–100 Ho 65 kA 35 kA 35 kA Non-Fusible Switches 30–100 FA 14 kA 14 kA 14 kA 30–100 FH 18 kA 18 kA 18 kA 200 H, J o 65 kA 35 kA 35 kA 400 LA 22 kA 22 kA 22 kA 400 LH 25 kA 25 kA 25 kA m Applies to NEMA 1, 3R, 4X stainless, 12 switches. n Ampere rating of fuse or circuit breaker not to exceed switch ampere rating. o All H and J circuit breakers are acceptable, but will only support the noted Short Circuit Current Ratings. 3-6 DE1 Discount Schedule 240 Vac © 2012 Schneider Electric All Rights Reserved Heavy Duty Safety Switches Special Applications Class 3110 / Refer to Catalog 3100CT0901 www.schneider-electric.us 316 Grade Stainless Steel—NEMA 3, 3R, 4, 4X, 5, 12 Type 316 stainless steel enclosure safety switches offer superior corrosion resistance to a wider range of chemicals than Type 304 stainless switches. Type 316 better resists chloride and is often used in marine, waste treatment and transportation applications. Use watertight hubs from page 3-10. Equipment grounding lugs are supplied as standard. (For Type 304 stainless switches see pages 3-4–3-6.) Table 3.14: 3P 600 Vac, 600 Vdc Horsepower Ratings– 3Øa Amperes Cat. No $ Price 480 Vac 600 Vac 600 Vdcb Std. Max. Std. Max. Max. Fusible H361SS 30 60 100 200 400 600 Non-Fusible 30 60 100 200 400 600 H361SS H362SS H363SS H364SS H365SS H366SS 3444.00 3792.00 7562.00 10592.00 21622.00 30528.00 5 15 25 50 100 150 15 30 60 125 250 400 7-1/2 15 30 60 125 200 20 50 75 150 350 500 15 30 50 50 50 50 HU361SS HU362SS HU363SS HU364SS HU365SS HU366SS 2898.00 3444.00 7029.00 9623.00 17758.00 26306.00 — — — — — — 20 50 75 125 250 400 — — — — — — 30 60 100 150 350 500 15 30 50 50 50 50 Fiberglass Reinforced Polyester Enclosures—NEMA 4X Fiberglass reinforced polyester enclosures are watertight, corrosion resistant, and impervious to windblown dust, rain, and splashing liquid. The molded fiberglass is extremely stable in a wide range of operating temperatures and can withstand heavy impact. Switches are furnished with hubs (page 3-14) and equipment grounding lugs. UL Listed. Table 3.15: Amperes H363DF Fusible 30 60 100 200 Non-Fusible 30 60 100 200 3P 600 Vac, 600 Vdc Cat. No. $ Price Cat. No. $ Price H361DF H362DF H363DF H364DF 3570.00 3968.00 7613.00 9729.00 RFK06 RFK06H RFK10 HRK1020 HU361DF HU362DF HU363DF HU364DF 3402.00 3782.00 7241.00 9695.00 — — — — Horsepower Ratings– 3Øa Electrical Interlock Kits Field-Installed Cat. No. Class R Fuse Kits 480 Vac 600 Vac 600 Vdcb 1 NO/1 NC Contacts 2 NO/2 NC Contacts Std. Max. Std. Max. Max. 25.50 25.50 47.70 47.70 9999TC10 9999TC10 9999TC10 9999R8 9999TC20 9999TC20 9999TC20 9999R9 5 15 25 50 15 30 60 125 7-1/2 15 30 60 20 50 75 150 15 30 50 50 — — — — 9999TC10 9999TC10 9999TC10 9999R8 9999TC20 9999TC20 9999TC20 9999R9 — — — — 20 50 75 125 — — — — 30 60 100 — 15 30 50 50 Krydon™ Enclosures—NEMA 4X Krydon enclosures are compression molded of fiberglass reinforced polyester, specially formulated to withstand attack from almost any corrosive atmosphere found in the toughest industrial application. Switches are furnished with hubs (page 3-14) and equipment grounding lugs. UL Listed. Amperes 3P, 600 Vac, 600 Vdc Cat. No. $ Price Cat. No. H361DX Fusible 30 60 100 Non-Fusible 30 60 100 Electrical Interlock Kits Field-Installed Cat. No. Class R Fuse Kits H361DX H362DX H363DX 4161.00 4626.00 8858.00 RFK06 RFK06H RFK10 HU361DX HU362DX HU363DX 3960.00 4406.00 8438.00 — — — $ Price Horsepower Ratings– 3Øa 480 Vac 600 Vac 600 Vdcb 1 NO/1 NC Contact 2 NO/2 NC Contacts Std. Max. Std. Max. Max. 25.50 25.50 47.70 9999TC10 9999TC10 9999TC10 9999TC20 9999TC20 9999TC20 5 15 25 15 30 60 7-1/2 15 30 20 50 75 15 30 50 — — — 9999TC10 9999TC10 9999TC10 9999TC20 9999TC20 9999TC20 — — — 20 50 75 — — — 30 60 100 15 30 50 SAFETY SWITCHES Table 3.16: An enclosed automatic molded case switch for use in Divisions 1 and 2 of the following: Class I, Groups C and D; Class II, Groups E, F and G; or Class III, Hazardous Locations as defined in NEC™ Article 500. Furnished with threaded conduit openings in both top and bottom endwall (page 3-14). Suitable for use as service equipment and listed as “Raintight’’ for outdoor applications. cULus Listed. Equipment grounding lugs supplied as standard. Table 3.17: Amperes H60XFA a b c d e f © 2012 Schneider Electric All Rights Reserved 3 Pole Molded Case Switch, 600 Vac, 250 Vdc Maximum, Short Circuit Current Rating 10 kA AIR Enclosed Molded Case Switchc Solid Neutral Assembly Cat. No. $ Price Cat. No. 60 H60XFA 2571.00 100SNA 60 H60XFA1212d 2886.00 100SNA 100 H100XFA 3045.00 100SNA 100 H100XFA1212d 3287.00 100SNA 225 H225XJGf 6387.00 225SNA 225 H225XJGAAdf 6701.00 225SNA Std.—Using fast acting one time fuses. Max.—Using dual element time delay fuses. For switching dc use two switching poles. Includes PKDB1, breather and drain kit, required for rainproof application—NEMA 7 only. Includes auxiliary contacts. For available options, contact customer service prior to placing an order. Not UL listed or CSA Certified due to wire bending space. DE1 Discount Schedule Horsepower Ratings—3Ø $ Price 143.00 143.00 143.00 143.00 189.00 189.00 240 Vac 15 15 30 30 60 60 480 Vac 30 30 60 60 125 125 600 Vacb 50 50 75 75 150 150 3-7 3 NEMA 7 and 9 UL508 Motor Disconnect Switches MD Motor Disconnect Switches Class 3110 / Refer to Catalog 3100CT0901 www.schneider-electric.us The MD motor disconnect switch is listed UL508 Suitable For Motor Control (UL File E164864). It is in a compact NEMA 4X enclosure suitable for use in NEMA Type 1, 3, 3R, 4, 4X and 12 applications. The MD's key benefits are an extremely small footprint, a more economically efficient NEMA 4X solution and a handle interlock preventing cover removal when the switch is in the ON position. Table 3.18: MD Motor Disconnect Switch—Non Metallic NEMA 1, 3, 3R, 4, 4X and 12 Enclosureabc Maximum Horse Power Ratings Amperes a b c Cat. No. $ Price Height (in.) 220–240 440–480 600 30 MD3304X 7.5 20 25 121.00 6.38 60 MD3604X 20 40 40 161.00 8.27 See table 8.9 for accessories. Complies with OSHA lockout/tagout requirements—accepts up to three 8 mm padlocks. Suitable for NEMA 1, 3R, 4, 4X and 12 enclosure applications. Table 3.19: D Three Phase Vac Cat. No. MDSAN20 MDSAN11 MDS30P Width (in.) Depth (in.) 3.9 4.94 4.37 4.37 MD Motor Disconnect Accessories Description 2 Normally open auxiliary contact module 1 normally open and 1 normally closed auxiliary contact module 30 Amp Add on power pole $ Price 57.00 27.00 35.00 H W MD Motor Disconnect Switches 3 SAFETY SWITCHES 3-8 DE1 Discount Schedule © 2012 Schneider Electric All Rights Reserved Heavy Duty Safety Switches Receptacle Switches Class 3110 / Refer to Catalog 3100CT0901 www.schneider-electric.us Interlocked Receptacle Switches Interlocked Receptacle Switches are furnished with a factory-installed three-phase four-wire Appleton Powertite™, Crouse-Hinds Style 2 Arktite™, or Hubbellock™ receptacle. The fourth wire is connected to the switch equipment grounding terminal and is not a neutral termination. Interlocking linkage between the receptacle and switch mechanism prevents insertion or removal of the plug while the switch is in the “ON’’ position or insertion of any plug other than specified. Grounding lugs are included. Appleton Powertite Receptacle • • • Devices are UL Listed and CSA Certified, suitable for use as service equipment. Receptacles are epoxy powder coated over copper-free cast aluminum and NEMA 3, 3R, 4, 4X and 12 rated. Appleton receptacles are UL Classified for use with the Crouse-Hinds plugs listed below. Short circuit rating: 10 kA when used in conjunction with Class H or K fuses; 200 kA when used in conjunction with Class R or J fuses. NEMA 3, 3R, 4, 4X, 5, 12 304 Stainless Steel Enclosure NEMA 1 Amperes Cat. No. H362AWA Interlocked Receptacle Switch with Appleton Powertite Receptacle $ Price Cat. No. $ Price Cat. No. Horsepower Ratings–3Øb Use with Plug a NEMA 12, 3R $ Price Cat. No. 480 Vac $ Price 600 Vac 250 Vdcc Std. Max. Std. Max. Std. Max. Fusible—3P, 600 Vac, 250 Vdc 30 H361WA 2076.00 H361DSWA 4401.00 H361AWA 2289.00 ACP3034BC 1235.00 5 15 7-1/2 20 5 60 H362WA 2412.00 H362DSWA 4668.00 H362AWA 2508.00 ACP6034BC 1295.00 15 30 15 50 10 100 H363WA 3689.00 H363DSWA 8468.00 H363AWA 3758.00 ACP1034CD 1928.00 25 60 30 75 20 Non-Fusible—3P, 600 Vac, 250 Vdc 30 HU361WA 1893.00 HU361DSWA 4001.00 HU361AWA 2076.00 ACP3034BC 1235.00 — 20 — 30 — 60 HU362WA 2306.00 HU362DSWA 4412.00 HU362AWA 2357.00 ACP6034BC 1295.00 — 50 — 60 — 100 HU363WA 3153.00 HU363DSWA 8010.00 HU363AWA 3347.00 ACP1034CD 1928.00 — 75 — 100 — a Receptacle UL Listed for use with “Appleton ACP or CPH” plugs; UL Classified for use with Crouse-Hinds “APJ” Arktite plugs listed on this page. b Std.—Using fast acting one time fuses. Max.—Using dual element time delay fuses. c For switching dc, use two switching poles. — — — 5 10 20 Crouse-Hinds Arktite Receptacle • • UL Listed, suitable for use as service equipment. Short circuit ratings: 10 kA when used in conjunction with Class H or K fuses; 200 kA when used in conjunction with Class R or J fuses. Table 3.20: Amperes Cat. No. H362AWC Interlocked Receptacle Switch with Crouse-Hinds Arktite Receptacle $ Price Cat. No. $ Price NEMA 12, 3R Cat. No. Horsepower Ratings–3Ød Use with Plug $ Price Fusible—3P, 600 Vac Maximum 30 H361WC 2139.00 H361DSWC 6377.00 H361AWC 2355.00 60 H362WC 2751.00 H362DSWC 7749.00 H362AWC 2846.00 100 H363WC 6005.00 H363DSWC 14826.00 H363AWC 6087.00 Non-Fusible—3P, 600 Vac Maximum 30 HU361WC 1952.00 HU361DSWC 5888.00 HU361AWC 2136.00 60 HU362WC 2634.00 HU362DSWC 7374.00 HU362AWC 2678.00 100 HU363WC 5249.00 HU363DSWC 14025.00 HU363AWC 5444.00 d Std.—Using fast acting one time fuses. Max.—Using dual element time delay fuses. Cat. No. $ Price 480 Vac 600 Vac Std. Max. Std. Max. APJ3485 APJ6485 APJ10487 1235.00 1295.00 1928.00 5 15 — 15 30 60 7-1/2 15 — 20 50 75 APJ3485 APJ6485 APJ10487 1235.00 1295.00 1928.00 — — — 20 50 60 — — — 30 60 100 Hubbellock Receptacle • • UL Listed, suitable for use as service equipment. Short circuit rating: 10 kA. Note: The Hubbellock receptacle switch utilizes the Square D interlocked plug SD12781 available only from Square D. SAFETY SWITCHES NEMA 3, 3R, 4, 4X, 5, 12 304 Stainless Steel Enclosure NEMA 1 Table 3.21: Cat. No. $ Price NEMA 12 Cat. No. $ Price Use with Plug Cat. No. $ Price Fusible—3P, 600 Vac Maximum 60 H362WH 2351.00 H362AWH 2459.00 SD12781f 609.00 Non-Fusible—3P, 600 Vac Maximum 60 HU362WH 2237.00 HU362AWH 2310.00 SD12781f 609.00 e Std.—Using fast acting one time fuses. Max.—Using dual element time delay fuses. f Hubbell plug is furnished with a Kellems grip for 1-1/2 in. to 1-21/64 in. cable diameter. Horsepower Ratings—3Øe 480 Vac 600 Vac 3 NEMA 1 Amperes Std. Max. Std. Max. 15 30 15 50 — 50 — 60 Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . pages 3-10 through 3-12. H362AWH Interlocked Receptacle Switch with Hubbell™ Hubbellock Receptacle © 2012 Schneider Electric All Rights Reserved DE1 Discount Schedule 3-9 Heavy Duty Safety Switches Accessories Class 3110 / Refer to Catalog 3100CT0901 www.schneider-electric.us Rainproof Bolt-On Hubs—for use on NEMA 3R Enclosure RB Hub Conduit Size 3/4 1 1-1/4 1-1/2 2 2-1/2 3 3-1/2 4 Closing Cap Hub Cat. No. B075 B100 B125 B150 B200 B250 B300 B350 B400 BCAP $ Price Each 33.30 33.30 33.30 33.30 61.00 102.00 186.00 300.00 368.00 3.80 (DE1A) Note: NEMA 3R rainproof enclosures with Cat. No. ending in RB have a bolt-on closing cap factory-installed. Order bolt-on hubs separately from table above. For more details see page 1-13. Hubs through size 2-1•2 can be directly installed on RB devices. Devices requiring threeinch or larger hubs must have holes cut in the field. Gaskets are provided on three-inch and larger hubs. Note: All hubs are UL Listed for indoor and rainproof applications and suitable for use with conduit having ANSI standard taper pipe thread. Watertight Hubs—for use on NEMA 4, 4X and 5 Stainless Steel and NEMA 12 Enclosures Conduit Trade Size 1/2 3/4 1 1-1/4 1-1/2 2 2-1/2 3 3-1/2 4 Standard-Zinc Hub Cat. No. H050 H075 H100 H125 H150 H200 H250 H300 H350 H400 138.00 177.00 282.00 Zinc $ Price Each Chrome Plated Hub Cat. No. Chrome Plated $ Price Each 31.10 45.00 47.10 54.00 83.00 120.00 H050CP H075CP H100CP H125CP H150CP H200CP — — — — 40.70 56.00 64.00 67.00 96.00 137.00 — — — — Electrical Interlock Kits Table 3.24: Electrical interlocks for heavy duty 30–1200 A safety switches are available factory-installed or in kit form for field installation. Each kit contains instructions for proper field mounting. A pivot arm operates from switch mechanism, breaking the control circuit before the main switch blades break. Switches with electrical interlocks installed are UL Listed. For factory-installed electrical interlocks add EI (for one contact) or EI2 (for two contacts) suffix to catalog number. See Supplemental Digest page 2-3 for electrical interlock contact ratings. Table 3.22: Electrical Interlock Kit a 3 SAFETY SWITCHES Switch’s Series Number Electrical Interlock Kit $ Price Factory-Installed Amperes Rating (See pages 3-13, 3-14) Cat. No.b $ Price EIK031c d F1, F5–F7 218.00 359.00 EIK032c d 30 EIK1 F3 311.00 452.00 EIK2 EIK1 F1-F3 311.00 452.00 F5–F7 (600 V) EIK2 60 EIK031e F4 218.00 359.00 F5–F6 (240 V) EIK032e EIK1 100–200 F2–F7 311.00 452.00 EIK2 EIK40601 400–1200 E1–E4 533.00 674.00 EIK40602 a See page 3-7 for electrical interlocks on NEMA 4X fiberglass reinforced polyester and Krydon™. b Electrical interlock kit catalog numbers with 1 suffix indicates one normally open and one normally closed contact; 2 indicates two normally open and two normally closed contacts. Kits are UL Listed. c HU461AWK uses EK3061 or EK3062. d The following Series F5–F7 devices use EIK-1, 2: H3612, H3612A, H3612AWK, H3612RB, H461, H461DS, H461AWK, HU461, HU461DS, HU661DS, HU661AWK, H361AWA, H361AWC, HU361AWA and HU361AWC. e H362WA, HU362WA, H362WC, H362AWA, HU362AWA, H362AWC, HU362AWC, and H2212AWK use EIK1 or EIK2 electric interlock. f Single-pole single-throw interlock kits are rated 1/2 hp @ 110 and 220 Vac. Class R Fuse Kits When installed, this kit rejects all but Class R fuses. Kits are available for field installation. For factory installation, add “CLR’’ suffix to catalog number. Table 3.23: Class R Fuse Kits—240 V (one kit per 3P switch) Series Number Class R Fuse Kit (See pages 3-13, 3-14) Cat. No. 30 F5–F7 RFK03Lg 60 F1, F2, F3 RFK06 60 F4–F7 RFK03H 100 F2–F7 RFK10 200 F5–F6 HRK1020 400–600 E HRK4060 g H221-2AWK uses RFK06 Class R fuse kit. Amperes $ Price 25.50 25.50 25.50 47.70 47.70 111.00 Series Number Class R Fuse Kit $ Price Factory-Installed (See pages 3-13, 3-14) Cat. No. $ Price 30h F1, F5–F7 RFK03Hi 25.50 293.00 30 h F3 RFK06 25.50 293.00 60 h F1–F7 RFK06H i 25.50 293.00 100 h F2–F7 RFK10 47.70 231.00 200 F5–F6 HRK1020 47.70 231.00 400–600 E2–E4 HRK4060 111.00 360.00 h See page 3-7 for Class R Fuse Kits in NEMA 4X Fiberglass Reinforced Polyester and Krydon switches. i The following Series F5–F7 devices use RFK06: H3612, H3612A, H3612AWK, H3612RB, H461, H461DS, H461AWK, H361AWA and H361AWC. Internal Barrier Kits Internal Barrier Kits provide an additional barrier that helps prevent accidental contact with live parts. Field-installed transparent barriers do not restrict visual inspection of the switch. Barriers provide IEC529 IP2X “finger safe” protection when door of enclosed disconnect switch is open. Convenient door allows use of test probes without accessing fuses and replacement of fuses without removing barrier. Barrier can also be used with the skirt kit to enclose a panel mounted Type 9422 disconnect. Safety Switch Application 9422 Type T (F Series Only) Disconnect Application $ Price 240 / 600 Vac – 30 A Interior Barrier for 30 A SS03 NA 150. Safety Switchj 240 Vac – 60 A Interior Barrier for 60 A 600 Vac – 30 A SS06 Safety Switch, 30 or 600 Vac – 60 A 165. 600 Vac – 60 A 60 A 9422 Switch Interior Barrier for 100 A SS10 Safety Switch or 240 / 600 Vac – 100 A 600 Vac – 100 A 195. 100 A 9422 Switch Interior Barrier for 200 A SS20 240 / 600 Vac – 200 A NA 225. Safety Switch Skirt Kit to Enclose 30 or 600 Vac – 30 A SS0306SK 60 A 9422 Switch NA 225. 600 Vac – 60 A (requires SS06) Skirt Kit to Enclose 100 A SS10SK 9422 Switch NA 600 Vac – 100 A 255. (requires SS10) j Requires arc shield on 240 V switches be changed to 600 V arc suppressor. Cat. No. Description Fuse Puller Kits Factory-Installed $ Price 195.00 195.00 195.00 231.00 231.00 360.00 DE1 Class R Fuse Kits—600 V (one kit per 3P switch) Amperes Kit consists of three fuse pullers as required for a 3-pole fusible 240 V or 600 V heavy duty switch. Kits can be installed in switches manufactured after February, 1980. Fuse pullers supplied as standard equipment on NEMA 12, 12K, NEMA 4, 4X, 5 stainless steel, NEMA 4X fiberglass reinforced polyester and KRYDON switches through 100 A. k l 3-10 381.00 DE1A Amperes Series Number Fuse Puller Kit Cat. No. $ Price 30 30 F1, F5–F7 F3 FPK03 k FPK0610 30.00 42.60 60 60 l F1, F2, F3, F5–F7 (600 V) F4 l, F5–F7 (240 V) FPK0610 FPK03 l 42.60 30.00 100 F2–F7 FPK0610 42.60 30 A 4- and 6-pole, H361-2 and H361-2RB Series F5 use FPK0610. H362WA, H362WC, H362AWA, H362AWC, H362WH and H362AWH use FPK0610 fuse puller kit. Discount Schedule © 2012 Schneider Electric All Rights Reserved Heavy Duty Safety Switches Accessories and Special Features Class 3110 / Refer to Catalog 3100CT0901 www.schneider-electric.us Neutral Assemblies—Field-Installed Neutral Assemblies for Fusible and Non-Fusible 240 and 600 Volt Safety Switches Series Number Amperes (See pages 3-13, 3-14) 30 F1, F5–F6 F1–F3, F5–F6 (600 V) F4, F5–F6 (240 V) 60 Standard Neutral Kit Cat. No. SN03a SN0610 SN03a Terminal Data AWG/kcmil Copper Only $ Price Optional Neutral Kit Cat. No. (3) 2 Max. Al/Cu (2) 1/0 Max. Al/Cu (2) 6 Max. Al/Cu (3) 2 Max. Al/Cu (3) 6 Max. Cu (2) 1/0 Max. Cu (2) 6 Max. Cu 102.00 114.00 83.00 SN03Ca 107.00 SN0610C SN20A 200.00 SN20C H600SN (4) 750 Max. Al/Cu (1) 300 Max. Al/Cu 327.00 H600SNC 753.00 — — — 1034.00 — — — F2–F6 SN0610 200b F5–F6 400 and 600 E1–E4 (6) 750 Max. Al/Cu (2) 350 Max. Al/Cu (8) 750 Max. Al/Cu 1200 E2–E4 H1200SNE4 (2) 350 Max. Al/Cu Note: Neutrals cannot be installed in 4P, 6P, or 200 A NEMA 4X fiberglass reinforced polyester safety switches. a The following Series F5–F6 devices use SN0610(C): H-361-2, H-361-2RB, H-361-2A and H-361-2AWK. b For 200% neutral, order (2) neutral kits and (1) SN20NI neutral jumper kit. (2) 350 Max. Al/Cu. E2–E4 SN03C a SN0610C $ Price (2) 1/0 Max. Al/Cu (2) 6 Max. Al/Cu (2) 250 Max. Al/Cu (1) 1/0 Max. Al/Cu 100 800 83.00 107.00 Terminal Data AWG/kcmil H800SNE4 (3) 6 Max. Cu 102.00 (2) 1/0 Max. Cu (2) 6 Max. Cu (2) 250 Max. Cu (1) 1/0 Max. Cu (2) 600 Max. Cu (2) 350 Max. Cu (1) 250 Max. Cu 114.00 246.00 452.00 Equipment Grounding Kitsg Equipment grounding kits are field-installed and UL Listed in 30–1200 A heavy duty switches. For factory installation of equipment grounding kit, add suffix GL to standard Cat. No. (Example: H361GL). Price = Switch + Kit Price. Equipment Grounding Kits—Field- or Factory-Installed Equipment Grounding Kits–240 and 600 V 30 60 d 60 Standard Cat. No. GTK03 c GTK0610 d GTK03 Terminal Data AWG/kcmil (2) 12 Cu or (2) 10 Al or (1) 4 Max. Al/Cu Optional Copper Only Cat. No. 11.40 GTK03C c Terminal Data AWG/kcmil (1) 6 Max. Cu (2) 1/0 Max. Al/Cu 18.90 GTK0610Cd (2) 4 Max. Cu 22.70 (2) 12 Cu or (2) 10 Al or (1) 4 Max. Al/Cu 11.40 GTK03C (1) 6 Max. Cu 13.40 $ Price $ Price 13.40 GTK0610 (2) 1/0 Max. Al/Cu 18.90 GTK0610C (2) 4 Max. Cu 22.70 PKOGTA2 (2) 2/0 Max. Al/Cu 55.00 PKOGTC2 (2) 4 Max. Cu 58.00 PKOGTA2e PKOGTC3 400 and 600 E2–E4 (2) 2/0 Max. Al/Cu 55.00 (3) 1/0 Max. Cu 107.00f (2 Required) 800 E2–E4 PKOGTA7 (4) 350 Max. Al/Cu 198.00f — — — 1200 E2–E4 PKOGTA8 (8) 350 Max. Al/Cu 203.00f — — — c The following Series F5–F6 devices use GTK0610(C): H-361-2 and H-361-2RB. d 4- and 6-pole 30 A F Series. e Two required if grounding conductors are run in parallel. f PE1A Discount Schedule g Equipment Ground Kits are factory-installed standard in 30–200 A series F NEMA 4-4X-5 (stainless) and 12. Equipment Ground Kits are standard on all NEMA Types, Series F 30–200 A 4 and 6 pole switches. Table 3.25: Square D Gray Paint Description 16 oz. Aerosol Paint Can, Square D Gray Paint Note: Shipped in quantities of 6. Price Adder Each Switch Cat. No. PK49SP $ Price 39.00 ea. Quantity $ Price 30 A 242.00 10 60 A 278.00 100 A 434.00 200 A 479.00 400 A 1137.00 Special Paint Lock-Off Guard Kitsd UL Listed heavy duty switches are available painted with special safety colors. To order safety colored switches add suffixes as noted in Table 3.26 to the standard switch commercial reference number. All colors comply with OSHA Standard 1910.144 and ANSI Specification Z535.1 for marking physical hazards. Available factory- or field-installed the lock-off guard works by covering the lockout/tagout opening whenever the switch is in the ON position. This prevents a padlock from being inadvertantly inserted into the switch lockplate. The device is designed to help prevent accidental misapplication of a lockout device. These kits are marked cURus (UL Component Recognized) for field or factory installation. Table 3.26: Safety Colors Safety Color Suffix Black SP0 Red SP2 Orange SP3 Yellow SP4 Green SP5 Blue SP6 Purple SP7 Gray SP8 Gray ANSI 61 SP861a White SP9 a Standard Square D ANSI 49 grey paint, when selecting this suffix, switches will receive additional coat of paint. A minimum quantity of 10 is required. Not available for NEMA Type 7/9 or stainless steel products. Amperesc 30 A 60 A 240 V 60 A 600 V 100 and 200 A b c d © 2012 Schneider Electric All Rights Reserved DE1 PE1A 600 A 2801.00 800 A 3501.00 1200 A 4376.00 3 100 200 Series Number (See pages 3-13, 3-14) F1, F5–F7 F1–F3d, F5–F7 (600 V) F4, F5–F6 (240 V) F2–F7 F5–F7 FactoryInstalled $ Price Kit Cat. No. Field-Installed $ Price LOGK1 44.30 146.00 LOGK2 45.00 177.00 For factory installation, add suffix “LOG” to the switch catalog number. For use with 30–200 Ampere Series F NEMA 1, 3R, 12 and 12K switches only. Factory install and kits are available for NEMA 1, 3R, 12 and 12K switch enclosures only. Discount Schedule SAFETY SWITCHES Amperes 3-11 Heavy Duty Safety Switches Accessories and Special Features Class 3110 / Refer to Catalog 3100CT0901 www.schneider-electric.us Key Interlock Systems Factory-installed only on heavy duty safety switches and double throw safety switches. Interlocks are used to prevent the authorized operator from making an unauthorized operation. Not available on hazardous location devices (NEMA 7/9) or fiberglass reinforced polyester (NEMA 4X). The key interlock system is a simple and easy method of applying individual key interlock units and assemblies to the above equipment so as to require operation in a predetermined sequence. UL Listed. Copper Only Lug Kits Heavy duty safety switches are supplied standard with Al lugs, which accept both Cu and Al wires. For field installation of copper-only lug kits, order kits below. For factory installation of copper only lugs, add suffix SLC to standard Cat. No. Note: 30 through 200 Amperes NEMA 12, 12K and stainless steel switches with factory-installed lugs bear the UL Marine Listed manifest for use on vessels over 65 feet long. 30 through 200 Amperes NEMA 12, 12K and stainless steel switches using fieldinstalled copper only lug kits are UL Marine Listed, but do not bear the marine manifest. Table 3.30: Quoting: Contact Schneider Electric for catalog number, availability, and pricing prior to quoting a job. Detailed information is required before an order can be processed. Please see Supplemental Digest Section 2 for further information. Use these suffixes on switch catalog numbers: • • • Double Lug Kits KI = 1 lock per switch KI2 = 1 lock with 2 cylinders (2 keys) per switch KIKI = 2 separate locks per switch Table 3.27: a Price Adder Per Lock a Switch Type $ Price 30–1200 A Heavy Duty 2055.00 30–600 A Double Throw 1988.00 Prices do not apply when more than three devices are interlocked, as these schemes normally require more than one key assembly per device. Al/Cu to Cu Only Lug Kitc Cat. No. Amperes Lock-On Provisions Lock-off provisions are standard on all heavy duty safety switches. Provision for one 3•8-inch hasp padlock is available factory-installed on NEMA 1, 3R, 4-4X-5 stainless steel and 12 switches. This modification will allow the switch to be locked in the “ON’’ position. UL Listed. Table 3.28: Price Adder Per Each Switch 3 Safety Switch Rating To order, add suffix SPLO to standard catalog number. Example: H364-SPLO $ Price 30–1200 A 155.00 Cover Viewing Window SAFETY SWITCHES Optional cover viewing window is positioned over the blades to allow visual verification of “ON-OFF’’ status. Available on 30 through 1200 A heavy duty switches, all NEMA Types. (Not available on NEMA 4X fiberglass reinforced polyester, Krydon™ enclosures, or NEMA 7 and 9 devices.) Factory-installed only: add “VW’’ suffix to the Cat. No. See table below for price adder. Table 3.29: Class Heavy Duty Heavy Duty Double Throw Price Adder Per Switch—UL Listed Amperes 30–100 A 400–1200 A 30–100 A 2- and 3-Pole 38.00 2297.00 255.00 4- and 6-Pole 75.00 — 510.00 Kit $ Priced 200 A heavy duty F-series switches are supplied standard with lugs listed on page 3-13 (one wire per phase). For lugs that accept two wires per phase and neutral, order the following kit: Lug wire range per phase and neutral AWG/kcmil (2) 6 –300 Cu/Al Field maintenance lubricant is available for servicing blade and jaw components in switches 600 V and below. Catalog number SWLUB (list price $24.14) consists of one tube of BG20 High Performance Synthetic Grease manufactured by Dow Corning®. SWLUB is available in warehouse stock, shipped individually or in multiples of 12 units per carton. Table 3.31: 800 and 1200 A Compression Lug Kits– Field- Installed (See page 3-13 for 100–600 A Switches) Series E4 800 and 1200 A safety switches are equipped as standard with mechanical lugs. Alternate compression lug kits are available for field installation and are UL Listed. Each kit consists of VCEL07512H1 Versa-Crimp™ Compression Lugs and lug landing connectors capable of converting line and load side of one switch pole or neutral. Order one field-installed kit per pole or neutral per table below. Example: Three-pole three-wire requires three kits; three-pole, four-wire requires four kits. Lug Kit Cat. No. 800 H8LKE2 1200 H12LKE2 Note: For terminal lug data, refer to table below. Amperes Amperes System 2 Wire 800 3 Wire 4 Wire 2 Wire 1200 3 Wire 4 Wire Note: For terminal Lug data refer to table below. Amperes 800 1200 DE5 $ Price Per Pole or Neutral 893.00 1109.00 Table 3.32: Factory-Installed Series E4 800 and 1200 A safety switches are available with factoryinstalled VCEL-075-12H1 Versa-Crimp compression lug kits (above). For factory installation, add suffix LK to standard Cat. No. (Example: H367LK) and use price adder from table below based on system type. Table 3.33: DE1 Switch wire range per phase and neutral AWG/kcmil (2) 6 –250 Cu/Al 200 AL20DTF 159.00 c Not UL Listed. d Kit contains 3 lugs. For double lugs for line and load, order 2 kits. Switch Lubricant 3-12 Kits–Wire size (pp 3-13) Lug Kit Kit Factory-Installed Amperes Cat. No.b $ Price Adder per Switch 30 CL0306F 69.00 224.00 60 CL0306F 69.00 224.00 100 CL10F 159.00 431.00 200 CL20F 264.00 717.00 400 CL40F 549.00 1490.00 600 CL60F 893.00 2426.00 800 — — — 1200 — — — bOne kit includes all phase line/load lugs for a 3pole switch. Discount Schedule Factory-Installed $ Price Adder Per Switch 2106.00 2972.00 3839.00 2591.00 3696.00 4806.00 Terminal Lug Data—800 and 1200 A Compression Lugs Conductors Per Phase (3) Line and (3) Load (4) Line and (4) Load Compression Lug (VCEL-075-12H1) Wire Range 500–750 kcmil (Al) or 500 kcmil (Cu) 500–750 kcmil (Al) or 500 kcmil (Cu) © 2012 Schneider Electric All Rights Reserved Heavy Duty Safety Switches NEMA Type 1 and 3R—Dimensions, Lug Data Class 3110 / Refer to Catalog 3100CT0901 www.schneider-electric.us Table 3.34: Rating (A) W 30c 60d 100 200e D W/H W/H D Typical NEMA 3R Approximate Dimensions Cat. No. H221N H221NRB H222N H222NRB H223N H223NRB H224N H224NRB H225, N H225NR, R H226, N H226NR, R H227, N H227NR, R H228, N H228NR, R H265 H265R H266 H266R H267 H267R H268 H268R H321N H321NRB H322N H322NRB H323N H323NRB H324N H324NRB H325, N H325R, NR H326, N H326R, NR H327, N H327R, NR H328, N H328R, NR H361, N H361-2 H361NRB, RB H361WA H361WC H362, N H362NRB, RB H362WA H362WC H362WH H363, N H363NRB, RB H363WA H363WC Series F5 F5 F5 F5 F5 F5 F5 F5 E4 E5 E4 E5 E4 E4 E4 E4 E4 E5 E4 E5 E4 E4 E4 E4 F5 F5 F5 F5 F5 F5 F5 F5 E4 E5 E4 E5 E4 E4 E4 E4 F5 F5 F5 F6 F6 F5 F5 F6 F6 F5 F5 F5 F6 F6 © 2012 Schneider Electric All Rights Reserved H in. 14.60 14.88 14.60 14.88 21.25 21.25 29.00 29.25 50.25 50.31 50.25 50.31 69.13 69.13 69.13 69.13 50.25 50.31 50.25 50.31 69.13 69.13 69.13 69.13 14.60 14.88 14.60 14.88 21.25 21.25 29.00 29.25 50.25 50.31 50.25 50.31 69.13 69.13 69.13 69.13 14.60 17.50 14.88 18.19 18.19 17.50 17.50 18.19 16.75 18.19 21.25 21.25 21.85 21.85 W mm 371 378 371 378 540 540 737 743 1276 1278 1276 1278 1756 1756 1756 1756 1276 1278 1276 1278 1756 1756 1756 1756 371 378 371 378 540 540 737 743 1276 1278 1276 1278 1756 1756 1756 1756 371 445 378 462 462 445 445 462 425 462 540 540 462 555 in. 6.50 6.63 6.50 6.63 8.50 8.50 17.13 17.25 27.63 27.76 27.63 27.76 36.62 36.62 36.62 36.62 27.63 27.76 27.63 27.76 36.62 36.62 36.62 36.62 6.50 6.63 6.50 6.63 8.50 8.50 17.13 17.25 27.88 27.76 27.63 27.76 36.62 36.62 36.62 36.62 6.50 9.00 6.63 9.00 9.00 9.00 9.00 9.00 9.00 9.00 8.50 8.50 9.00 9.00 in. 4.88 4.88 4.88 4.88 6.38 6.38 8.25 8.50 10.13 9.53 10.13 9.53 17.75 17.75 17.75 17.75 10.13 9.53 10.13 9.53 17.75 17.75 17.75 17.75 4.88 4.88 4.88 4.88 6.38 6.38 8.25 8.50 10.13 9.53 10.13 9.53 17.75 17.75 17.75 17.75 4.88 6.38 4.88 6.81 6.81 6.38 6.38 6.81 7.00 6.81 6.38 6.38 6.81 6.81 12–2 (Al) or 14–2 (Cu) 12–2 (Al) or 14–2 (Cu) 12–1/0 (Al) or 14–1/0 (Cu) 6–300 (Al/Cu) — — Approximate Dimensions D mm 165 168 165 168 216 216 435 438 702 705 702 705 930 930 930 930 702 705 702 705 930 930 930 930 165 168 165 168 216 216 435 438 708 705 702 705 930 930 930 930 165 229 168 229 229 229 229 229 229 229 216 216 229 229 Optional Versa-Crimp™ Compression Lug Field-Installedb VCEL02114S1 VCEL030516H1 VCEL07512H1 1 1/0–750 (Al/Cu)f 1/0–750 (Al/Cu) or 400 or or and VCEL030516H1g 2 1/0–300 (Al/Cu) 1/0–300 (Al/Cu) and VCEL05012H1 600 2 3/0–500 (Al/Cu) 3/0–500 (Al/Cu) VCEL05012H1 800 3 3/0–750 (Al/Cu) 3/0–750 (Al/Cu) H8LKE2h 1200 4 3/0–750 (Al/Cu) 3/0–750 (Al/Cu) H12LKE2 h o a 30–100 A switches suitable for 60°C or 75°C conductors. 200–1200 A switches suitable for 75 C conductors. b For NEMA 1 and 3R only. c HU461AWK— 14–3 AWG (Al or Cu). d H60XFA— 14–6 AWG (Cu). e H225XKA— 4 AWG–300 kcmil (Cu). f Max. wire range is (1) 600 kcmil or (2) 300 kcmil Al/Cu on NEMA 4X Stainless and NEMA 12. g Order two PK516KN mounting kits when installing VCEL030516H1 lugs. Only one kit is required on 2-Pole switches. h See page 3-12, 800 and 1200 A compression lug kits for additional information. H Typical NEMA 1 1 1 1 Lug Wire Range AWG/kcmil W/H mm 124 124 124 124 162 162 210 216 257 242 257 242 451 451 451 451 257 242 257 242 451 451 451 451 124 124 124 124 162 162 210 216 257 242 257 242 451 451 451 451 124 162 124 173 173 162 162 173 178 173 162 162 173 173 in. 7.55 7.55 7.55 7.55 10.50 10.50 18.50 18.63 27.63 27.88 27.63 27.88 36.62 36.62 36.62 36.62 27.63 27.88 27.63 27.88 36.62 36.62 36.62 36.62 7.55 7.55 7.55 7.55 10.50 10.50 18.50 18.63 27.88 27.88 27.63 27.88 36.62 36.62 36.62 36.62 7.55 10.50 7.55 10.50 10.50 10.50 10.50 10.50 10.50 10.50 10.50 10.50 10.50 10.50 Cat. No. mm 192 192 192 192 267 267 470 473 702 708 702 708 930 930 930 930 702 708 702 708 930 930 930 930 192 192 192 192 267 267 470 473 708 708 702 708 930 930 930 930 192 267 192 267 267 267 267 267 267 267 267 267 267 267 H364, N H364RB, NRB H365, N H365R, NR H366, N H366NR, R H367, N H367NR, R H368, N H368NR, R H461 H462 H463 H464 H465 H466 HU265 HU265R HU266 HU266R HU267 HU267R HU268 HU268R HU361 HU361RB HU361WA HU361WC HU362 HU362RB HU362WA HU362WC HU362WH HU363 HU363RB HU363WA HU363WC HU364 HU364RB HU365 HU365R HU366 HU366R HU367 HU367R HU368 HU368R HU461 HU462 HU463 HU464 HU465 HU466 Series F5 F5 E4 E5 E4 E5 E4 E4 E4 E4 F5 F5 F5 F5 E4 E4 E4 E5 E4 E5 E4 E4 E4 E4 F5 F5 F6 F6 F5 F5 F6 F6 F5 F5 F5 F6 F6 F5 F5 E4 E5 E4 E5 E4 E4 E4 E4 F5 F5 F5 F5 E4 E4 H in. 29.00 29.25 50.25 50.31 50.25 50.31 69.13 69.13 69.13 69.13 20.50 20.50 20.50 29.00 50.25 50.25 50.25 50.31 50.25 50.31 69.13 69.13 69.13 69.13 14.60 14.88 18.19 18.19 17.50 17.50 18.19 16.75 18.19 21.25 21.25 21.85 21.85 29.00 29.25 50.25 50.31 50.25 50.31 69.13 69.13 69.13 69.13 20.50 20.50 20.50 29.00 50.25 50.25 W mm 737 743 1276 1278 1276 1278 1756 1756 1756 1756 521 521 521 737 1276 1276 1276 1278 1276 1278 1756 1756 1756 1756 371 378 462 462 445 445 462 425 462 540 540 462 555 737 743 1276 1278 1276 1278 1756 1756 1756 1756 521 521 521 737 1276 1276 in. 17.13 17.25 27.63 27.76 27.63 27.76 36.62 36.62 36.62 36.62 14.75 14.75 14.75 23.25 33.88 33.88 27.63 27.76 27.63 27.76 36.62 36.62 36.62 36.62 6.50 6.63 9.00 9.00 9.00 9.00 9.00 9.00 9.00 8.50 8.50 9.00 9.00 17.13 17.25 27.63 27.76 27.63 27.76 36.62 36.62 36.62 36.62 14.75 14.75 14.75 23.25 33.88 33.88 D mm 435 438 702 705 702 705 930 930 930 930 375 375 375 591 861 861 702 705 702 705 930 930 930 930 165 168 229 229 229 229 229 229 229 216 216 229 229 435 438 702 705 702 705 930 930 930 930 375 375 375 591 861 861 in. 8.25 8.50 10.13 9.53 10.13 9.53 17.75 17.75 17.75 17.75 6.85 6.85 6.85 8.75 10.13 10.13 10.13 9.53 10.13 9.53 17.75 17.75 17.75 17.75 4.88 4.88 6.81 6.81 6.38 6.38 6.81 7.00 6.81 6.38 6.38 6.81 6.81 8.25 8.50 10.13 9.53 10.13 9.53 17.75 17.75 17.75 17.75 6.85 6.85 6.85 8.75 10.13 10.13 W/H mm 210 216 257 242 257 242 451 451 451 451 174 174 174 222 257 257 257 242 257 242 451 451 451 451 124 124 173 173 162 162 173 178 173 162 162 173 173 210 216 257 242 257 242 451 451 451 451 174 174 174 222 257 257 in. 18.50 18.63 27.63 27.88 27.63 27.88 36.62 36.62 36.62 36.62 16.13 16.13 16.13 24.88 33.88 33.88 27.63 27.88 27.63 27.88 36.62 36.62 36.62 36.62 7.55 7.55 10.50 10.50 10.50 10.50 10.50 10.50 10.50 10.50 10.50 10.50 10.50 18.50 18.63 27.63 27.88 27.63 27.88 36.62 36.62 36.62 36.62 16.13 16.13 16.13 24.88 33.88 33.88 mm 470 473 702 708 702 708 930 930 930 930 410 410 410 632 861 861 702 708 702 708 930 930 930 930 192 192 267 267 267 267 267 267 267 267 267 267 267 470 473 702 708 702 708 930 930 930 930 410 410 410 632 861 861 3-13 SAFETY SWITCHES H 2 Wire Range Wire Bending Space Per NEC Table 312.6 AWG/kcmil 12–6 (Al) or 14–6 (Cu) 14–10 (Cu) solid or 14–10 (Cu) stranded 14–3 (Al) or 14–3 (Cu) 12–1/0 (Al) or 14–1/0 (Cu) 6–250 (Al/Cu) 3 W Terminal Lug Data (NEMA 1, 3R, 4, 4X, 5, 7, 9, 12)a Conductors Per Phase and Neutral 1 Heavy Duty Safety Switches NEMA Types 4, 4X, 5, 7, 9, 12 and 12K Dimensions Class 3110 / Refer to Catalog 3100CT0901 www.schneider-electric.us NEMA Type 4, 4X, 5, 7, 9 and 12 W Approximate Dimensions Cat. No. W D H H H W/H D Typical NEMA 4X Typical NEMA 4, 4X, 5, 12, Fiberglass Reinforced 12K (Stainless has flat front) Polyester and Krydon™ Table 3.35: W D Typical NEMA 7, 9 Optional Copper Only Lug Kits (See page 3-12 for pricing. See page 3-13 for terminal lug data for the series switches listed in the dimension table below.) Amperes Optional Lug Kit Cat. No.a Lug Wire Range Per Phase AWG/kcmil 30–60 CL0306F (1) 14–8 Cu solid or 14–4 Cu strand 100 CL10F (1) 14–8 Cu solid or 14–1/0 Cu strand 200 CL20F (1) 6–250 Cu 400 CL40F (1) 1–600 Cu plus (1) 6–250 Cu 600 CL60F (2) 4–350 Cu a One kit includes all phase line/load lugs for a 3-pole switch. Table 3.36: Conduit Provisions (NEMA 4X Fiberglass Reinforced Polyester and Krydon, NEMA 7 and 9.) Top and Bottom Endwall Amperes b c NEMA 4X Fiberglass Reinforced Polyester and Krydonb 30 3/4 in. 60 1-1/4 in. 100 2 in. 200 2-1/2 in. Hubs and hub drilling templates are provided for field-installation. Threaded conduit opening. NEMA 7 and 9c — 3/4 in. 1-1/4 in. 2-1/2 in. Approximate Dimensions Cat. No. 3 SAFETY SWITCHES H60XFA H100XFA H221AWK, A H221DS H221-2AWK H222AWK, A H222DS H223AWK, A H223DS H224A,AWK H224DS H225AWK, DS H225NAWK, NDS H225XJG H226AWK, DS H226NAWK, NDS H227AWK, NAWK H228AWK, NAWK H265AWK, DS H266AWK, A, DS H267AWK, NAWK H268AWK, NAWK H321AWK, A H321DS H322AWK, A H322DS H323AWK, A H323DS H324A,AWK H324DS H325AWK, DS H325NAWK, NDS H326AWK, DS H326NAWK, NDS H327AWK, NAWK H328AWK, NAWK H361AWA H361AWC H361AWK, A H361DS H361DSWA H361DSWC H361DF H361DX H361SS H361-2AWK, A H362AWA H362AWC H362AWH H362AWK, A H362DS 3-14 Series E1 E1 F6 F6 F6 F6 F6 F6 F6 F6 F6 E4 E4 C2 E4 E4 E4 E4 E4 E4 E4 E4 F6 F6 F6 F6 F6 F6 F6 F6 E4 E4 E4 E4 E4 E4 F7 F7 F6 F6 F7 F7 F1 F1 F6 F6 F7 F7 F6 F6 F6 H in. 15.93 15.93 14.60 14.93 16.50 14.60 14.93 20.50 20.82 29.00 29.00 46.25 46.25 22.56 46.25 46.25 69.13 69.13 46.25 46.25 69.13 69.13 14.60 14.93 14.60 14.93 20.50 20.82 29.00 29.00 46.25 46.25 46.25 46.25 69.13 69.13 16.50 16.50 14.60 14.93 16.87 16.87 16.50 19.40 14.93 16.50 16.50 16.50 16.50 16.50 16.87 W mm 405 405 371 379 419 371 379 521 529 737 737 1175 1175 573 1175 1175 1756 1756 1175 1175 1756 1756 371 379 371 379 521 529 737 737 1175 1175 1175 1175 1756 1756 419 419 371 379 428 428 419 493 379 419 419 419 419 419 428 in. 9.87 9.87 6.63 7.22 9.00 6.63 7.22 9.00 9.36 17.25 17.75 26.25 26.25 10.88 26.25 26.25 36.62 36.62 26.25 26.25 36.62 36.62 6.63 7.22 6.63 7.22 9.00 9.36 17.25 17.75 26.25 26.25 26.25 26.25 36.62 36.62 9.00 9.00 6.63 7.22 8.92 8.92 11.00 11.40 7.22 9.00 9.00 9.00 9.00 9.00 8.92 D mm 251 251 168 183 229 168 183 229 238 438 451 667 667 276 667 667 930 930 667 667 930 930 168 183 168 183 229 238 438 451 667 667 667 667 930 930 229 229 168 183 227 227 279 290 183 229 229 229 229 229 227 in. 6.96 6.96 4.96 5.11 7.00 4.96 5.11 7.00 6.97 8.75 8.88 10.13 10.13 7.75 10.13 10.13 17.75 17.75 10.13 10.13 17.75 17.75 4.96 5.11 4.96 5.11 7.00 6.97 8.75 8.88 10.13 10.13 10.13 10.13 17.75 17.75 7.00 7.00 4.96 5.11 5.11 5.11 8.80 8.60 5.11 7.00 7.00 7.00 7.00 7.00 6.97 W/H mm 177 177 125 130 178 125 130 178 177 216 226 259 259 197 259 259 451 451 259 259 451 451 125 130 125 130 178 177 216 226 259 259 259 259 451 451 178 178 125 130 130 130 224 218 130 178 178 178 178 178 177 in. 9.87 9.87 7.55 8.67 10.50 7.55 8.67 10.50 11.25 18.63 19.25 26.25 26.25 10.88 26.25 26.25 36.62 36.62 26.25 26.25 36.62 36.62 7.55 8.67 7.55 8.67 10.50 11.25 18.63 19.25 26.25 26.25 26.25 26.25 36.62 36.62 10.50 10.50 7.55 8.67 10.81 10.79 11.00 11.40 8.67 10.50 10.50 10.50 10.50 10.50 10.81 mm 251 251 192 220 267 192 220 267 286 473 489 667 667 276 667 667 930 930 667 667 930 930 192 220 192 220 267 286 473 489 667 667 667 667 930 930 267 267 192 220 275 274 279 290 220 267 267 267 267 267 275 H362DSWA H362DSWC H362DF H362DX H362SS H363AWA H363AWC H363AWK, A H363DS H363DSWA H363DSWC H363DF H363DX H363SS H364A,AWK H364DS,NDS H364NA,NAWK H364DF H364SS H365AWK, DS, SS H365NAWK, NDS H366AWK, DS H366NAWK, NDS, SS H367AWK, NAWK H368AWK, NAWK H461AWK H461DS H462AWK H462DS H463AWK H463 DS H464AWK H464DS H465AWK H663AWK H663DS H664AWK H664DS HU265AWK, DS HU266AWK, DS HU267AWK HU268AWK HU361AWA HU361AWC HU361AWK, A HU361DS HU361DSWA HU361DSWC HU361DF HU361DX HU361SS HU362AWA HU362AWC HU362AWH HU362AWK, A HU362DS HU362DSWA HU362DSWC HU362DF HU362DX HU362SS HU363AWA HU363AWC HU363AWK, A HU363DS HU363DSWA HU363DSWC HU363DF HU363DX HU363SS HU364A,AWK HU364DF HU364DS HU364SS HU365AWK, DS, SS HU366AWK, DS, SS HU367AWK HU368AWK HU461AWK HU461DS HU462AWK HU462DS HU463AWK HU463DS HU464AWK HU464DS HU465AWK HU661AWK HU661DS HU662AWK HU662DS HU663AWK HU663DS HU664AWK HU664DS Series F7 F7 F1 F1 F6 F7 F7 F6 F6 F7 F7 F1 F1 F6 F6 F6 F6 E1 F6 E4 E4 E4 E4 E4 E4 F6 F6 F6 F6 F6 F6 F6 F6 E4 F6 F6 F6 F6 E4 E4 E4 E4 F7 F7 F6 F6 F7 F7 F1 F1 F6 F7 F7 F6 F6 F6 F7 F7 F1 F1 F6 F7 F7 F6 F6 F7 F7 F1 F1 F6 F6 E1 F6 F6 E4 E4 E4 E4 F6 F6 F6 F6 F6 F6 F6 F6 E4 F6 F6 F6 F6 F6 F6 F6 F6 H in. 16.87 16.87 16.50 19.40 16.87 20.50 20.50 20.50 20.82 20.82 20.82 24.80 25.25 20.82 29.00 29.00 29.00 31.30 29.00 46.25 46.25 46.25 46.25 69.13 69.13 20.50 20.82 20.50 20.82 20.50 20.82 29.00 29.00 46.25 20.50 20.82 29.00 29.00 46.25 46.25 69.13 69.13 16.50 16.50 14.60 14.93 16.87 16.87 16.50 19.40 14.93 16.50 16.50 16.50 16.50 16.87 16.87 16.87 16.50 19.40 16.87 20.50 20.50 20.50 20.82 20.82 20.82 24.80 25.25 20.82 29.00 31.30 29.00 29.00 46.25 46.25 69.13 69.13 20.50 20.82 21.25 20.82 20.50 20.82 29.00 29.00 46.25 20.50 20.82 20.50 20.82 20.50 20.82 29.00 29.00 W mm 428 428 419 493 428 521 521 521 529 529 529 630 641 529 737 737 737 795 737 1175 1175 1175 1175 1756 1756 521 529 521 529 521 529 737 737 1175 521 529 737 737 1175 1175 1756 1756 419 419 371 379 428 428 419 493 379 419 419 419 419 428 428 428 419 493 428 521 521 521 529 529 529 630 641 529 737 795 737 737 1175 1175 1756 1756 521 529 540 529 521 529 737 737 1175 521 529 521 529 521 529 737 737 in. 8.92 8.92 11.00 11.40 8.92 9.00 9.00 9.00 9.36 9.36 9.36 13.70 11.40 9.36 17.25 17.75 17.25 26.30 17.75 26.25 26.25 26.25 26.25 36.62 36.62 14.75 15.08 14.75 15.08 14.75 15.08 23.25 23.75 32.50 14.75 15.08 23.25 23.75 26.25 26.25 36.62 36.62 9.00 9.00 6.63 7.22 8.92 8.92 11.00 11.40 7.22 9.00 9.00 9.00 9.00 8.92 8.92 8.92 11.00 11.40 8.92 9.00 9.00 9.00 9.36 9.36 9.36 13.70 11.40 9.36 17.25 26.30 17.75 17.75 26.25 26.25 36.62 36.62 14.75 15.08 16.13 15.08 14.75 15.08 23.25 23.75 32.50 14.75 15.08 14.75 15.08 14.75 15.08 23.25 23.75 D mm 227 227 279 290 227 229 229 229 238 238 238 348 290 238 438 451 438 668 451 667 667 667 667 930 930 375 383 375 383 375 383 591 603 826 375 383 591 603 667 667 930 930 229 229 168 183 227 227 279 290 183 229 229 229 229 227 227 227 279 290 227 229 229 229 238 238 238 348 290 238 438 668 451 451 667 667 930 930 375 383 410 383 375 383 591 603 826 375 383 375 383 375 383 591 603 in. 5.11 5.11 8.80 8.60 6.97 7.00 7.00 7.00 6.97 6.97 6.97 12.00 8.60 6.97 8.75 8.88 8.75 11.80 8.88 10.13 10.13 10.13 10.13 17.75 17.75 6.80 6.97 6.80 6.97 6.80 6.97 8.75 8.88 10.13 6.80 6.97 8.75 8.88 10.13 10.13 17.75 17.75 7.00 7.00 4.96 5.11 5.11 5.11 8.80 8.60 5.11 7.00 7.00 7.00 7.00 6.97 5.11 5.11 8.80 8.60 6.97 7.00 7.00 7.00 6.97 6.97 6.97 12.00 8.60 6.97 8.75 11.80 8.88 8.88 10.13 10.13 17.75 17.75 6.80 6.97 6.80 6.97 6.80 6.97 8.75 8.88 10.13 6.80 6.97 6.80 6.97 6.80 6.97 8.75 8.88 W/H mm 130 130 224 218 177 178 178 178 177 177 177 305 218 177 216 226 216 300 226 259 259 259 259 451 451 173 177 173 177 173 177 222 226 259 173 177 222 226 259 259 451 451 178 178 125 130 130 130 224 218 130 178 178 178 178 177 130 130 224 218 177 178 178 178 177 177 177 305 218 177 216 300 226 226 259 259 451 451 173 177 173 177 173 177 222 226 259 173 177 173 177 173 177 222 226 in. 10.81 10.79 11.00 11.40 10.81 10.50 10.50 10.50 11.25 11.25 11.25 13.70 11.40 11.25 18.63 19.25 18.63 26.30 19.25 26.25 26.25 26.25 26.25 36.62 36.62 16.13 16.85 16.13 16.85 16.13 16.85 24.88 25.25 32.50 16.13 16.85 24.88 25.25 26.25 26.25 36.62 36.62 10.50 10.50 7.55 8.67 10.81 10.79 11.00 11.40 8.67 10.50 10.50 10.50 10.50 10.81 10.81 10.79 11.00 11.40 10.81 10.50 10.50 10.50 11.25 11.25 11.25 13.70 11.40 11.25 18.63 26.30 19.25 19.25 26.25 26.25 36.62 36.62 16.13 16.85 16.13 16.85 16.13 16.85 24.88 25.25 32.50 16.13 16.85 16.13 16.85 16.13 16.85 24.88 25.25 mm 275 274 279 290 275 267 267 267 286 286 286 348 290 286 473 489 473 668 489 667 667 667 667 930 930 410 428 410 428 410 428 632 641 826 410 428 632 641 667 667 930 930 267 267 192 220 275 274 279 290 220 267 267 267 267 275 275 274 279 290 275 267 267 267 286 286 286 348 290 286 473 668 489 489 667 667 930 930 411 428 410 428 410 428 632 641 826 410 428 410 428 410 428 632 641 © 2012 Schneider Electric All Rights Reserved Double Throw Safety Switches Fusible and Non-Fusible Class 3140 / Refer to Catalog 3100CT0901 www.schneider-electric.us 30–100 A Types DT, DTU (Series F) •Fusible (DT) and non-fusible (DTU) switches available •Manually-operated switch suitable for use in accordance with article 702 of the NEC, ANSI/NFPA 70 •Standards: UL 98, NEMA KS1, CSA, and NOM •Modular design—switch handle, lock-plate, switch mechanism; line and load bases are field replaceable •UL Listed short circuit current ratings up to 200 kA (using Class R, J, or T fuses—see table for rating) •Load make/break rated •Meets NEMA hp ratings •Dual cover interlock •May be padlocked ON (I) or OFF (O) •Lock-off accepts up to three padlocks •Side-opening door •Quick make / quick break mechanism •Meets NEMA requirements as heavy duty switch •Field-installed electrical interlock kits •Field-installed neutral assembly kits (2P and 3P switches) •UL Listed as suitable for use as service equipment •Supplied as standard for switching one load between two power sources, and may be field-converted to switch on power source between two loads. 30 (Series T4), 200–600 A Types 82,000 and 200 A DTU (Series E, A) •Non-fusible •Designed for manual transfer of loads from one supply to another •UL Listed switches are suitable for use in accordance with Article 702 of the National Electrical Code, ANSI / NFPA 70 •All 82,000 and DTU double throw switches are continuous duty rated for their nameplate ampere rating •The 82,000 and DTU (Series E, A) switches are load make/break rated •UL Listed as suitable for use as service equipment •Horsepower rated only as footnoted. Field-Installed Accessories: SAFETY SWITCHES —Neutral —Electrical Interlock —Grounding Terminals 3 30–100 A DT, DTU (Series F) NEMA 1 82,000 Line NEMA 1 © 2012 Schneider Electric All Rights Reserved 3-15 Double Throw Safety Switches 240 Volt Class 3140 / Refer to Catalog 3100CT0901 www.schneider-electric.us Table 3.37: 240 V Double Throw Safety Switches Horsepower Ratings ab System Amperes Current Series NEMA 1 NEMA 4,4X,5 304 Stainless Steel NEMA 3R NEMA 12 Gasketed 240 Vac Std. Cat. No. $ Price Max. Cat. No. $ Price Cat. No. $ Price Cat. No. $ Price 1Ø 3Ø 1Ø 3Ø 250 Vdcc Fusible—2P, 240 Vac—250 Vdc Line F DT223 2379.00 DT223RB 3056.00 — — — — 7.5 15 d 15 30 d 20 30 60 F F DT321 DT322 1646.00 1970.00 DT321RB DT322RB 2216.00 2612.00 — — — — — — — — 1.5 e 3e 3d 7.5 d 3e 10 e 7.5 d 15 d 5 10 100 F DT323 3104.00 DT323RB 3725.00 — — — — 7.5 e 15 d 15 e 30 d 20 — DTU223RB — 1347.00 — — — — — — — — — — — — 10 15 — — 10 f 20 f 100 Line Load Fusible—3P, 240 Vac—250 Vdc Line Line Load Non-Fusible—2P, 240 Vac—250 Vdc Line Line 60 100 F F DTU222 DTU223 962.00 1371.00 30 200 — 400 T4 E — A 92251 g 82254 k — 82255 g 585.00 — 1815.00 DTU224NRB ghk — — 5850.00 82255R g — 2177.00 — 8715.00 — — — — — — — — — H82254 — H82255 g — 4671.00 — 10335.00 — 15 15 — — — — — — — — — — — — — — — — — 804.00 1119.00 1764.00 — — 1953.00 — — — — — — — — — — — — — — — 3d — — 5e 10 e 15 e 10 d 15 d 30 d 5f 10 f 20 f 687.00 — — 2564.00 DTU324NRB gh 3005.00 2798.00 — — 8040.00 82355R g 13038.00 12555.00 DTU326R 13890.00 — — — — — — — — — — — — — — — — 15 15 — 125 — — — — — — — — — — — — — — 50 Load 3 Non-Fusible—3P, 240 Vac—250 Vdc Line SAFETY SWITCHES 30 60 100 F F F DTU321 DTU322 DTU323 30 200 200 400 600 Non-Fusible—4P, 240 Vac 30 200 400 T4 E E A A 92351 g 82354 g DTU324N gh 82355 g DTU326 T4 E A 92451 82454 k 82455 953.00 5184.00 11505.00 — 82454R k 82455R — 7517.00 16200.00 — — — — — — — H82454 j H82455 — 6779.00 15975.00 — — — — 15 j — — — — — — — — — — 600 A DTU426 20355.00 DTU426R 20595.00 — — — — — 125 — — 50 Line — — DTU323RB Load a b c d e f g h i j k — — H82354 gi 5408.00 — — H82355 g 11715.00 — — Refer to page 7-31 for additional motor application data. The starting current of motors or more than standard horsepower may require the use of fuses with appropriate time delay characteristics. Std.—Using fast acting one time fuses. Max.—Using dual element time delay fuses. For switching dc, use two switching poles. If used on corner grounded delta systems, install neutral and use outer switching pole for ungrounded conductors. Use outer switching poles. Maximum rating. 240 Vac only. Neutral included with device. Suitable for use as service equipment. Hp rating applies only to H82454. 250 V dc rated. 600 V Double Throw . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 3-17 Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 3-18 Application Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 3-19 Dimensions: 30–100 A (Series F) . . . . . . . . . . . . . . . . . . . . . . . . . page 3-20 Dimensions: 30, 200–600 A (Series E, T4, A) . . . . . . . . . . . . . . . . page 3-21 3-16 DE1 Discount Schedule © 2012 Schneider Electric All Rights Reserved Double Throw Safety Switches 600 Volt Class 3140 / Refer to Catalog 3100CT0901 www.schneider-electric.us Table 3.38: 600 V Double Throw Safety Switches Horsepower Ratings ao NEMA 1 Amperes Current Series System NEMA 4,4X,5 304 Stainless Steel NEMA 3R NEMA 12 Gasketed 240 Vac std max 480 Vac std 600 Vac max std max Cat. No. $ Price Cat. No. $ Price Cat. No. $ Price Cat. No. $ Price 3Ø 3Ø 3Ø b 3Øb 3Ø 3Ø DT361 DT362 DT363 2016.00 2111.00 3686.00 DT361RB DT362RB DT363RB 2678.00 3135.00 4427.00 — — — — — — — — — — — — — — — — — — 7.5 15 30 20 50 75 Vdcb 250 600 Fusible 3P, 600 Vac—600 Vdc Line 30 60 100 Line F F F 5 15 25 15 30 60 5 — — 15 30 50 10 30 40 30 5 60 g 10 75 h 20 15 30 50 — — 50 — — — Load 1Ø d 3Ø b 1Ø d 3Ø b 1Ø d 3Ø Non-Fusible 3P, 600 Vac—600 Vdc Line Line 30 60 100 F F F 200 400 600 E A A DTU361 DTU362 DTU363 879.00 DTU361RB 1254.00 DTU362RB 2036.00 DTU363RB 1544.00 — 2045.00 DTU362DS 3425.00 DTU363DS — — — 6306.00 DTU362AWK p 3635.00 9414.00 DTU363AWK p 3894.00 5 10 20 10 20e 40h 7.5 20 25 50 g 40 75 hi 82344jn 2783.00 82344RB jn 5868.00 82344DSjr 11415.00 H82344ljq 7503.00 82345 n 8213.00 82345R n 13140.00 82345DS n 15675.00 H82345 n 12105.00 DTU366 ns 13890.00 DTU366R ns 19800.00 — — DTU366AWKns 21675.00 — — — — — 125 — — — 15 k — 250 — — — — — 350 2Ø 3Ø 2Ø 3Ø 2Ø 3Ø 20 30 20 40 40 50 50 75 50 50 60 75 10 20 30 30 — — — — — 125 — — — — — 250 — — — — — 350 — — 50 — — — 1Ø 3Ø 1Ø 3Ø 1Ø 3Ø — — 20 40 — — 50 75 — — 60 75 10 20 30 50 Load Non-Fusible 4P, 600 Vac—600 Vdc Line Line 60 100 F F 200 400 600 E A A DTU462 DTU463 3035.00 Use NEMA 12 3851.00 — — DTU462DS DTU463DS 6683.00 DTU462AWK p 4184.00 9978.00 DTU463AWK p 6123.00 82444 n 6143.00 82444R n 8130.00 82444DS n 15105.00 82445 n 12578.00 82445Rn 16800.00 — — DTU466 n 20355.00 DTU466R n 23475.00 — — H82444 ljn 7143.00 H82445n 16845.00 — — Non-Fusible 6P, 600 Vac—600 Vdc Line Line 60 100 F F — — — — — — — — — — DTU662AWK p 8474.00 DTU663AWK p 12735.00 — — SAFETY SWITCHES Load 3 Load a b c d e f g h Refer to page 7-31 for additional motor application data. The starting current of motors or more than standard horsepower may require the use of fuses with appropriate time delay characteristics. If used on corner grounded delta systems, install neutral and use outer switching pole for ungrounded conductors. For switching dc, use two switching poles. Use outer switching poles. Maximum Hp is 15 for corner grounded delta systems. Maximum Hp is 30 for corner grounded delta systems. Use 75oC #4 Cu or #2 Al conductors only. Use 75oC #1 Cu conductors only. i j k l m n o p q r s Maximum Hp is 60 for corner grounded delta systems. 480 Vac maximum only, 250Vdc. Standard Hp rating. Not suitable for use as service equipment. 600 Vac max. 250 V dc rated. Std.—Using fast acting one time fuses. Max.—Using dual element time delay fuses. (Non-fusible switches have max rating unless noted.) Complete rating on switch is NEMA 3R or 12. For 3R applications, remove drain screw from bottom endwall. H82 ... and H92 ... devices are NEMA 12 only, intended for use indoors only. Not UL Listed. Copper lugs not listed or available. 240 V Double Throw . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 3-16 Accessories. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 3-18 Application Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 3-19 Dimensions: 30–100 A (Series F) . . . . . . . . . . . . . . . . . . . . . . . . . page 3-20 Dimensions: 30, 200–600 A (Series E, T4, A). . . . . . . . . . . . . . . . page 3-21 © 2012 Schneider Electric All Rights Reserved DE1 Discount Schedule 3-17 Double Throw Safety Switches Accessories Class 3140 / Refer to Catalog 3100CT0901 www.schneider-electric.us Table 3.38: Neutral Assembly Field-Installed Terminal Field-Installed Terminal Standard Neutral Kit Data $ Price Copper only Data $ Price Cat. No. AWG/kcmil Neutral Kit Cat. No. AWG/kcmil 30–100 A Type DT, DTU (Series F) (2- and 3-pole switches only) SN0310 14–1/0 Al/Cu 114.00 SN0310C 14–1/0 Cu 120.00 30 A (Series T4) (2- and 3-pole switches only) a a 908.00 — — — 200 A Type 82000 and DTU (Series E) b a a 1110.00 — — — (1) 4–600kcmil or 105.00 400 A Type 82000 DT400N — — — (2) 1/0–250kcmil 600 A Type DTU (Series A) DT600NKD 250–500kcmil 452.00 — — — a For Type 82,000 switches, neutral is available factory-installed on 2P and 3P double throw switches. Not UL Listed. To order, add suffix N to the standard catalog number and add the above price to the list price of the switch. For DTU switches, neutral is factory-installed in standard device and is UL Listed. b Neutral assembly catalog number DT200N can be added to 4P Type 82000 switches in the field. Switch Table 3.39: Electrical Interlocks (For Electrical Interlock Contact Ratings, see Supplemental Digest page 2-4.) Factory-Installed Field-Installed Electrical Interlock Kit Cat. No. c $ Price $ Price Adder Per Switch 30–100 A Type DT, DTU (Series F) EIK1, EIK2 dh 311.00 905.00e 200 A Type 82000 and DTU (Series E) f g — 1113.00e 400 A Type 82000 EK400DTU2 260.00 1533.00 600 A Type DTU (Series A) DS200EK2D 438.00 — c Electrical interlock kit catalog numbers with “1” suffix indicate one normally open and normally closed contact; “2” indicates two normally open and two normally closed contacts. See page 3-10 for electrical interlock ratings. d 30–100 A Type DT, DTU (Series F) switches contain (2) separate switching mechanisms. Each mechanism will accept an electrical interlock. Some applications may therefore require (2) electrical interlocks. e 30–100 A Type DT, DTU (Series F) switches with factory-installed electrical interlocks installed are UL Listed and interlocks are furnished with 2 N.O. /2 N.C. contacts installed in both “ON” positions. To order, add suffix EI to standard catalog number. f Electrical interlock EK400DTU2 can be added to 4-pole Type 82000 switches in the field. g Type 82000 and DTU switches are available with electrical interlock factory-installed only. Not UL listed. Electrical interlocks are furnished with 2 N.O./N.C. contacts and are installed in both “ON” positions. To order, add suffix EI to standard switch catalog number. h Double throw switches 92251, 92351, and 92451 are not available with factory or field installed electrical interlocks. Switch Table 3.40: Service Grounding Kit (Required for service equipment use.) Switch 30–100 A Type DT, DTU (Series F) 30 A Type 92,000 200 A Type 82000 and DTU (Series E) Field-Installed Service Grounding Lug Kit Cat. No. Included DT30SG DT100SG PKOGTA2 (2 required) DS468GKD 400 A Type 82000 600 A Type 82000 (Series A) Table 3.41: Terminal Data AWG/kcmil Included (4) 14–4 Cu/Al (3) 14–1/0 Cu/Al (4) 10–2/0 Cu or (4) 6–2/0 Al 6–250kcmil $ Price std. 29.40 30.00 55.00 309.00 Class R Fuse Kits When installed, this kit rejects all but Class R fuses. Kits are available for field installation. For factory installation, add “CLR” suffix to catalog number. Switch Series Number Class R Fuse Kit Cat. No. 3 Class R Fuse Kits—240 V (two kits per 3P switch) 30 A F5 60 A F5 100 A F5 Class R Fuse Kits—600 V (two kits per 3P switch) 30 A F5 60 A F5 100 A F5 $ Price Factory-Installed $ Price RFK03 RFK06 RFK10 24.50 25.50 47.70 390.00 390.00 390.00 RFK06 RFK06H RFK10 25.50 25.50 47.70 390.00 390.00 390.00 SAFETY SWITCHES Viewing Windows See Table 3.29 for list price. Accessory available on 30–100 A DTU switches only. Key Interlock Systems For factory-installed key interlocks, refer to page 3-12. Phenolic Legend Plate For factory-installed phenolic legend plates, refer to Supplemental Digest page 2.3. Lock-On Provisions—UL Listed Standard and feature on 30–100 A type DT and DTU (Series F), 82,000 (400 A only) and type 92,000 switches. Feature available as facatory installed option for Type 82,000 (200 A only) and 200 A DTU (Series E) switches. Add the suffix SPLO to the catalog number and add $410. to the switches list price. Table 3.42: “RB Hub” Rainproof Bolt-On Hubs—for use on NEMA 3R Enclosures Conduit Size 3/4 1 1-1/4 1-1/2 2 2-1/2 3 3-1/2 4 Closing Cap Hub Cat. No. B075 B100 B125 B150 B200 B250 B300 B350 B400 BCAP $ Price Eachi 33.30 33.30 33.30 33.30 61.00 102.00 186.00 300.00 368.00 3.80 Note: NEMA 3R rainproof enclosures with catalog number ending in RB have a bolt-on closing cap factory-installed. Order bolt-on hubs separately from table above. For more details see page 1-13. Hubs through size 2-1/2 in. can be directly installed on RB devices. Devices requiring 3 in. or larger hubs must have holes cut in the field. Gaskets are provided on 3 in. and larger hubs. Note: All hubs are UL Listed for indoor and rainproof applications and suitable for use with conduit having ANSI standard taper pipe thread. i See Discount Schedule. Table 3.43: Watertight Hubs—for use on NEMA 4, 4X and 5 Stainless Steel and NEMA 12 Enclosures Conduit Trade Size 1/2 3/4 1 1-1/4 1-1/2 2 2-1/2 3 3-1/2 4 Standard-Zinc Hub Cat. No. H050 H075 H100 H125 H150 H200 H250 H300 H350 H400 120.00 138.00 177.00 282.00 381.00 Zinc $ Price Each Chrome Plated Hub Cat. No. Chrome Plated $ Price Each 31.10 H050CP 45.00 H075CP 40.70 47.10 H100CP 56.00 64.00 54.00 H125CP 67.00 83.00 H150CP 96.00 H200CP 137.00 — — — — — — — — 240 V Double Throw . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 3-16 600 V Double Throw . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 3-17 Application Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 3-19 Dimensions: 30–100 A (Series F) . . . . . . . . . . . . . . . . . . . . . . . . . . page 3-20 Dimensions: 30, 200–600 A (Series E, T4, A) . . . . . . . . . . . . . . . . page 3-21 3-18 DE1 DE1A Discount Schedule © 2012 Schneider Electric All Rights Reserved Double Throw Safety Switches Application Data Class 3140 / Refer to Catalog 3100CT0901 www.schneider-electric.us 30–100 A Type DT (Series F): Select DT switches from pages 3-16, 3-17, which have provisions for accepting fuses. 30 A, 200–600 A Type 82,000 (Series E, T4, A), all DTU devices: Use the non-fusible double throw switches from pages 3-16, 3-17 in conjunction with standard fusible devices, and install them according to diagram 1 or 2, below. Line Non-Fusible Double Throw Switch Line Table 3.44: UL Listed Short Circuit Current Ratings Switch Type Type DT (Series F) DTU b Type (Series F) DTU224NRB and DTU324NRB (Series E) DTU324N (Series E) Voltage Rating UL Listed Fuse Class 30–100 A 240 V or 600 V 30–100 A 240 V or 600 V H, K R, J H or K R, J or T Short Circuit Current Rating a (A) 10,000 200,000 10,000 c 200,000 200 A 240 V H, K 10,000 c H, K 10,000 c R, J 100,000 H, K 10,000 c 240 V Type 82,000 all R, J 100,000 d 600 V H, K 10,000 c H, K 10,000 Type DTU (A series) 600 A 240 V or 600 V R, J, T 100,000 a Rating applies to AC only. The UL Listed short circuit current rating for non-fusible switches is based on the switch being used in conjunction with the corresponding fuse type. Evaluation of non-fusible switches in conjunction with molded case circuit breakers has not been performed. b The DTU361 and DTU361RB are also suitable for use on a circuit capable of delivering not more than (A) 18 kA, 600 Vac maximum when protected by Type FH circuit breaker rated 30 A maximum or (B) 14 kA, 600 Vac maximum when protected by Type FA circuit breaker rated 30 A maximum. c Any brand of circuit breaker or fuse not exceeding the ampere rating of the switch may be used ahead of a non-fusible safety switch when there is up to 10 kA short circuit current available. d 400 A 82,000 switch is only 10 kA. Table 3.45: 200 A 240 V Terminal Lug Data for Type DT, DTU (Series F) Double Throw Safety Switches NEMA 1, 3R, 4, 4X, 12 Wires per Phase Wire Range Wire Bending Space Per NEC Table 373-6 AWG/kcmil 30–60 A 12–2 Al Type DT, DTU 1 or (Series F) 14–2 Cu 100 A 12–1/0 Al Type DT, DTU 1 or (Series F) 14–1/0 Cu e Thomas and Betts catalog numbers. f Hubbell Versa-Crimp™ catalog numbers. Switch Type Fusible Single Throw Switch or Circuit Breaker Amperes Table 3.46: Load Standard Lug Wire Range AWG/kcmil 12–2 Al or 14–2 Cu 12–1/0 Al or 14–1/0 Cu Amperes Wires per Phase Wire Range Wire Bending Space Per NEC Table 373-6 AWG/kcmil 30 A (Series T4) h 1 14–8 Al/Cu Line 200 Non-Fusible Double Throw Switch Load 1 1 or 2 600 2 o 200–600 A switches suitable for 75 C conductors. 30 A switches suitable for 60oC or 75oC conductors. Hubbell Versa-Crimp™ catalog numbers. 400 g h i VCEL02114S1 f Optional Copper Only Lug See pages 3-12 and 3-14 for appropriate kit. Order two kits per switch. Terminal Lug Data for Types 82,000 and for A and E-Series DTU devices Diagram 1 Fusible Single Throw Switch or Circuit Breaker Optional Compression Lug Field-Installed C10-14, D8-14, or E6-14 e 6–300 Al/Cu 1/0–600 Al/Cu or 1/0–300 Al/Cu 250–500 Al/Cu Lug Wire Range AWG/kcmil g Optional Compression Lugs Field-Installed 12–2 Al or 14–2 Cu 6–300 Al/Cu VCEL030516H1 i 1/0–600 Al/Cu — 250–500 Al/Cu — — SAFETY SWITCHES Situations Requiring Fuses 240 V Double Throw . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .page 3-16 600 V Double Throw . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 3-17 Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .page 3-18 Dimensions: 30–100 A (Series F) . . . . . . . . . . . . . . . . . . . . . . . . . .page 3-20 Dimensions: 30, 200–600 A (Series E, T4, A). . . . . . . . . . . . . . . . .page 3-21 3 Fusible Single Throw Switch or Circuit Breaker Line Diagram 2 © 2012 Schneider Electric All Rights Reserved DE1 Discount Schedule 3-19 Double Throw Safety Switches Dimensions—Series F Devices Class 3140 / Refer to Catalog 3100CT0901 www.schneider-electric.us Table 3.47: W H D W/H NEMA 1 W H 3 W/H D 30–100 A Type DT, DTU (Series F)—Approximate Dimensions Cat. No. Series DT223 DT223RB DT321 DT321RB DT322 DT322RB DT323 DT323RB DT361 DT361RB DT362 DT362RB DT363 DT363RB DTU222 DTU223 DTU223RB DTU321 DTU322 DTU323 DTU323RB DTU361 DTU361RB DTU362 DTU362AWK DTU362DS DTU362RB DTU363 DTU363AWK DTU363DS DTU363RB DTU462 DTU462AWK DTU462DS DTU463 DTU463AWK DTU463DS DTU662AWK DTU663AWK F5 F5 F5 F5 F5 F5 F5 F5 F5 F5 F5 F5 F5 F5 F5 F5 F5 F5 F5 F5 F5 F5 F5 F5 F6 F6 F5 F5 F6 F6 F5 F5 F6 F6 F5 F6 F6 F6 F6 H in. 38.00 38.00 38.00 38.00 38.00 38.00 38.00 38.00 38.00 38.00 38.00 38.00 38.00 38.00 29.94 29.94 30.50 29.94 29.94 29.94 30.50 29.94 30.50 29.94 29.94 30.26 30.50 29.94 29.94 30.26 30.50 29.94 30.26 30.26 29.94 30.26 30.26 30.26 30.26 W mm 965 965 965 965 965 965 965 965 965 965 965 965 965 965 760 760 775 760 760 760 775 760 775 760 760 769 775 760 760 769 775 760 769 769 760 769 769 769 769 in. 9.88 6.87 10.25 10.25 10.25 10.25 9.88 6.87 10.25 10.25 10.25 10.25 9.88 6.87 10.25 10.25 10.25 10.25 10.25 10.25 10.25 10.25 10.25 10.25 10.25 10.25 10.25 10.25 10.25 10.25 10.25 10.25 15.50 15.50 10.25 15.50 15.50 15.50 15.50 W/H mm 251 174 260 260 260 260 251 174 260 260 260 260 251 174 260 260 260 260 260 260 260 260 260 260 260 260 260 260 260 260 260 260 394 394 260 394 394 394 394 in. 11.13 8.12 11.50 11.80 11.50 11.80 11.13 8.12 11.50 11.80 11.50 11.80 11.13 8.12 11.96 11.96 11.96 11.96 11.96 11.96 11.96 11.96 11.96 11.96 11.96 11.50 11.96 11.96 11.96 11.50 11.96 11.96 16.75 16.75 11.96 16.75 16.75 16.75 16.75 D mm 283 206 292 300 292 300 283 206 292 300 292 300 283 206 304 304 304 304 304 304 304 304 304 304 304 292 304 304 304 292 304 304 425 425 304 425 425 425 425 in. 6.75 6.60 6.75 6.60 6.75 6.60 6.75 6.60 6.75 6.60 6.75 6.60 6.75 6.60 6.93 6.93 6.93 6.93 6.93 6.93 6.93 6.93 6.93 6.93 6.93 7.12 6.93 6.93 6.93 7.12 6.93 6.93 7.12 7.12 6.93 7.12 7.12 7.12 7.12 mm 171 168 171 168 171 168 171 168 171 168 171 168 171 168 176 176 176 176 176 176 176 176 176 176 176 181 176 176 176 181 176 176 181 181 176 181 181 181 181 240 V Double Throw . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 3-16 600 V Double Throw . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 3-17 Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 3-18 Application Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 3-19 Dimensions: 30, 200–600 A (Series E, T4, A) . . . . . . . . . . . . . . . . page 3-21 NEMA 3R SAFETY SWITCHES W H W/H D NEMA 4, 4X, 5 and 12 3-20 © 2012 Schneider Electric All Rights Reserved Double Throw Safety Switches Dimensions—Series A, E, and T4 Devices Class 3140 / Refer to Catalog 3100CT0901 www.schneider-electric.us 30, 200–600 A Types 82,000 and E-Series DTU devices, NEMA 1 and 3R—Approximate Dimensions Cat. No. W/H W D H NEMA 1 W/H W D H DTU—200 A NEMA 3R DTU224NRB a 82254 a 82254NW a 82344 a 82344RB a 82354 92251 82344DS DTU324N DTU324NRB H82344 H82444 a H82454 82454 82444 82454R a 82444R H82254 H82354 82444DS a 82255 a 82255R 82345a 82345DSa 82345Ra 82355 a 82355R a 82445 82445R 82455 a 82455R H82255 H82345 H82355 H82445 H82455 DTU326 DTU426 DTU366 DTU466 DTU326R DTU426R DTU366R DTU466R DTU366AWK a 250 V dc rated. Series E1 E1 E1 E2 E1 E1 T4 E1 E1 E1 E2 E2 E3 E3 E3 E3 E3 E3 E3 E3 A1 A1 A1 A1 A1 A1 A1 A1 A1 A1 A1 A1 A1 A1 A1 A1 A1 A1 A1 A1 A1 A1 A1 A1 A1 H in. 32.50 30.88 30.88 30.88 32.50 30.88 10.00 30.88 32.50 32.50 32.50 32.50 32.50 38.00 38.00 38.00 38.00 32.50 32.50 38.00 38.50 39.00 38.50 39.00 39.00 38.50 39.00 38.50 39.00 38.50 39.00 39.00 39.00 39.00 39.00 39.00 63.31 63.31 63.31 63.31 63.76 63.76 63.76 63.76 63.76 W mm 826 784 784 784 826 784 254 784 826 826 826 826 826 965 965 965 965 826 826 965 978 991 978 991 991 978 991 978 991 978 991 991 991 991 991 991 1608 1608 1608 1608 1619 1619 1619 1619 1619 in. 20.63 15.75 20.00 20.00 20.63 20.00 8.00 20.00 24.50 24.50 24.50 30.21 30.21 29.62 29.62 29.62 29.62 24.50 24.50 29.62 26.10 26.62 26.10 26.62 26.62 26.10 26.62 30.10 30.21 30.10 30.21 26.62 26.62 26.62 30.21 30.21 23.66 27.00 23.66 27.00 23.66 27.00 23.66 27.00 23.66 W/H mm 524 400 508 508 524 508 203 508 622 622 622 767 767 753 753 753 753 622 622 753 663 676 663 676 676 663 676 765 767 765 767 676 676 676 767 767 601 686 601 686 601 686 601 686 601 in. 24.00 19.63 23.88 23.88 24.00 23.88 9.75 23.88 26.25 26.25 26.25 33.61 33.61 33.02 33.02 33.02 33.02 26.25 26.25 33.02 29.51 30.02 29.51 30.02 30.02 29.51 30.02 33.50 33.61 33.50 33.61 30.02 30.02 30.02 33.61 33.61 24.46 27.80 24.46 27.80 24.46 27.80 24.46 27.80 24.46 D mm 610 499 607 607 610 607 248 607 667 667 667 854 854 839 839 839 839 667 667 839 750 763 750 763 763 750 763 851 854 851 854 763 763 763 854 854 621 706 621 706 621 706 621 706 621 in. 10.63 9.75 11.75 11.75 10.63 11.75 4.75 11.75 10.63 10.63 10.63 10.63 10.63 10.63 10.63 10.63 10.63 10.63 10.63 10.63 10.63 10.63 10.63 10.63 10.63 10.63 10.63 10.63 10.63 10.63 10.63 10.63 10.63 10.63 10.63 10.63 8.88 8.88 8.88 8.88 8.88 8.88 8.88 8.88 8.88 mm 270 248 298 298 270 298 121 298 270 270 270 270 270 270 270 270 270 270 270 270 270 270 270 270 270 270 270 270 270 270 270 270 270 270 270 270 226 226 226 226 226 226 226 226 226 3 240 V Double Throw . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 3-16 600 V Double Throw . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 3-17 Accessories. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 3-18 Application Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 3-20 Dimensions: 30–100 A (Series F) . . . . . . . . . . . . . . . . . . . . . . . . . . page 3-20 SAFETY SWITCHES Table 3.48: © 2012 Schneider Electric All Rights Reserved 3-21 Dimensions 1000 Vdc Photovoltaic Heavy Duty Disconnect Switch Class 3110 www.schneider-electric.us Put over 100 years of Schneider Electric’s experience as a global specialist in energy management to work on your photovoltaic (PV) project. The Square D™ 1000 Vdc disconnect switch is the perfect solution for your 1000 Vdc PV disconnect applications. It is compact and available in both a 100 and 200 amp non-fusible versions. IEC 609471 and 3 certified (file 136861) and UL 98 certified (file E343341). Extended Life Expectancy Designed for Harsh PV Environments Exceeds IEC 60947-3 mechanical endurance requirements by factor of 18 Exceeds IEC 60947-1 electrical endurance requirements by factor of 10 Exceeds NEMA KS-1 mechanical endurance requirements by factor of 3. NEMA Type 3 and IP63 enclosure • • Resists windblown dirt/dust Exceeds NEMA Type 1, 3R and 12 Operating range of -37°C to 50°C Specially designed PV paint reduces solar gain up to 35% over standard grey enclosures Easy to Install Preconfigured solar solution Familiar enclosed safety switch design Suitable for both grounded and ungrounded PV Table 3.49: 1000 Vdc Photovoltaic Heavy Duty Disconnect Switch Pricing and Accessories Factory Installed Accessories NEMA 1, 3R, 12, 3 and IP63 System Amperes Cat. No. Electrical Interlock Electrical Interlock Single Contacta Two Contactsb Viewing Windows Terminal Blocks (Copper)c 3 Wire Ground Lugd Price No. Suffix $ Price No. $ Price No. $ Price No. $ Price $ Price No. Suffix $Adder Adder Suffix Adder Suffix Adder Suffix Adder Height Width (in.) (in.) Depth (in.) 3 Pole Groundede Three-Pole (Grounded System) Connector Line Connector 100 REHU393IP 1672.00 EI 452.00 EI2 496.00 VW 150.00 TBC 409.00 GL 263.00 22.13 18.63 8.75 200 REHU394IP 2246.00 EI 452.00 EI2 496.00 VW 175.00 TBC 409.00 GL 263.00 22.13 18.63 8.75 100 REHU493IP 2507.00 EI 452.00 EI2 496.00 VW 150.00 — — GL 263.00 29.00 18.63 8.75 200 REHU494IP 3965.00 EI 452.00 EI2 496.00 VW 175.00 — — GL 263.00 29.00 18.63 8.75 Load PE Protective earth terminal 3 4 Pole Ungrounded Four-Pole (Ungrounded System) SAFETY SWITCHES Load Line Load Line Connector PE Protective earth terminal a b c Order EIK1PV for single contact field-installed kit $311.00. Order EIK2PV for double contact field-installed kit $355.00. Accommodates (2) 250 max Cu or (1) 1/0 max Cu wiring; Order d e SN20CPV for field-installed kit $246.00. Order REHGND KIT for field installable kit $100.00. Terminal blocks standard with 3 pole switches; accommodates (2) 1/0 max Al/Cu or (2) 6 max Al/Cu wiring. Schneider Electric gives the Photovoltaic market place the most comprehensive one stop shop for Residential and Light Commercial Photovoltaic Balance of System components. Schneider Electric's Inverters, and Square D brand DC and AC disconnect switches and Load Centers are ideal solutions to your Balance of Systems requirements. See the Balance of System solution chart below for your single phase PV system. Table 3.50: 200 A Enclosed Switch Dimensions (inches) PV Balance of System Solution Package—Grid Tie System Voltage Kilowatts Amps DC Disconnect Inverter 250 Vdc 2.8 30 HU361RB 878-2801 D221NRB 250 Vdc 3.3 60 HU362RB 878-3301 D222NRB QO140M225 250 Vdc 3.3 100 HU363RB 878-3301 D223NRB QONQ42MS400 600 Vdc 3.8 30 HU361RB 878-3801 D221NRB QO130M200 600 Vdc 5.0 60 HU362RB 878-5001 D222NRB QO140M225 600 Vdc 5.0 100 HU363RB 878-5001 D223NRB QONQ42MS400 For internal 600 Vdc PV combiner box switches please see our offering of 9422 switches 600 Vdc UL98 listed in digest pages 8-14. 3-22 DE1 Discount Schedule AC Disconnect Load Center Product QO130M200 For our 600 Vdc PV switch offering please see digest pages 3-5–3-6. © 2012 Schneider Electric All Rights Reserved String Combiner Boxes Dimensions Class 3140 / Refer to Catalog 3100CT0901 www.schneider-electric.us Square D PV string combiner boxes are used to integrate multiple PV strings into one output circuit. Its tough exterior and safety features protect wiring from weather and overcurrent. The exterior coating ensures low operating temperatures and longer life of internal components. The specially engineered enclosure is designed to provide dust tight and rain tight protection; it meets or exceeds NEMA® 3R, 12, and 4 requirements. Traditional Square D visible blade switch architecture confirms disconnection, while touch-safe interior shielding protects against accidental contact with live components. Features Flexible • • • Vertical, horizontal, and angled mounting options Flexible installation with top, bottom, and side entry Substantial wire-bending space Robust • • • Dust tight and rain tight engineered enclosure for outdoor use UV-resistant white exterior coating to reduce solar gain by 35% Meets or exceeds NEMA 3R, 12, and 4 requirements Safe • • • • Square D traditional visible blade switch architecture for confirmation of disconnect Touch-safe interior shielding guards against accidental contact with current-carrying components Seismic-certified 100–400 amp string combiner boxes for earthquake safety Optional integrated 2.5 kV surge arrestor to protect PV electronics from lightning strikes Listings • UL 1741 • Switches tested to UL98B • CSA C22.2 Spec 107.1 600 Vdc Photovoltaic Combiner Boxes Maximum Wire Range (AWG/kcmil—Copper Only) Continuous Maximum Continuous Output DC Output PV Module Input List Input Output Circuit Number of Ground Current Isc Rating Current Price $ Circuit (+ and -) Conductors In (Max.) (Amps) Per String (+ and -) (+ or -) (Amps) REHSC126100 12 100 838.00 #12–#6 #6–1/0 1 REHSC166200 16 200 1067.00 #12–#6 #6–300 MCM 1 #14–4 Or 10.4 13 2X #14–#12 REHSC246300 24 300 1378.00 #12–#6 1/0–300 2 REHSC326400 32 400 2226.00 #12–#6 1/0–300 2 a For factory installed surge protection device add the suffix “S” to the catalog number. Catalog Numbera Table 3.52: Number Input Circuits (Max.) Width Depth Ground Out in. mm in. mm in. mm #6–2/0 #6–2/0 #6–2/0 #6–2/0 20.78 27.78 35.78 35.78 528 706 909 909 14.50 20.25 20.25 20.25 368 514 514 514 6.13 6.13 6.13 6.13 156 156 156 156 600 Vdc Photovoltaic Combiner Boxes With Disconnects Maximum Wire Range (AWG/kcmil—Copper Only) Continuous Maximum Continuous Output DC Output PV Module Input List Input Output Circuit Number of Ground Current Isc Rating Current Price $ Circuit (+ and -) Conductors In (Max.) (Amps) Per String (+ and -) (+ or -) (Amps) REHSC126100DU 12 100 1438.00 #12–#6 #6–1/0 1 REHSC166200DU 16 200 1899.00 #12–#6 #6–300 MCM 1 #14–4 Or 10.4 13 2X #14–#12 REHSC246300DU 24 300 3035.00 #12–#6 1/0–300 2 REHSC326400DU 32 400 3883.00 #12–#6 1/0–300 2 a For factory installed surge protection device add the suffix “S” to the catalog number. Catalog Numbera Outside Dimmensions Height Number Input Circuits (Max.) Outside Dimmensions Height Width Depth Ground Out in. mm in. mm in. mm #6–2/0 #6–2/0 #6–2/0 #6–2/0 31.00 31.00 41.00 41.00 787 787 1041 1041 19.00 25.00 25.00 25.00 483 635 635 635 9.00 9.00 10.50 10.50 229 229 267 267 SAFETY SWITCHES Table 3.51: The 600 Vdc Type 2 Surge Protection Device (SPD) is for medium risk PV applications. The SPD when installed in a Square D combiner box protects solar modules, power tracking and blocking diodes from physical damage resulting from lightning induced transients. The SPD device uses Metal Oxide Varistor (MOV)/Gas-Filled Spark Gap (GSP) protection circuits for longer life and no current leakage. The devices are UL1449 ed 2 compliant Low Voltage TVSS. The SP are available as factory installed by adding the suffix “S” to the combiner box catalog number or as kits a kit: REHTYPE2SP. Table 3.53: Typical String Combination Box Dimensions © 2012 Schneider Electric All Rights Reserved 600 Vdc Type 2 Surge Protection Device Catalog Number Network Voltage Nominal Discharge Current per 20 micro sec Maximum Discharge Current per 20 micro sec Operating Current Operating Temperature; Celsius List Price $ REHTYPE2SP 600 Vdc 20kA 40kA <0.1nA -40 to +85 Kit 337.00 Factory Installed 490.00 3-23 3 Surge Protection Device www.schneider-electric.us 3 SAFETY SWITCHES 3-24 © 2012 Schneider Electric All Rights Reserved
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.6 Linearized : Yes Create Date : 2014:10:23 10:57:57-04:00 Modify Date : 2014:10:23 10:57:57-04:00 XMP Toolkit : Adobe XMP Core 5.4-c005 78.147326, 2012/08/23-13:03:03 Metadata Date : 2014:10:23 10:57:57-04:00 Format : application/pdf Document ID : uuid:6e740c0c-54f4-4f63-aaa5-ce4cdb31ad43 Instance ID : uuid:1307862d-0c67-4e71-8456-289bfdd0c594 Page Mode : UseNone Page Count : 24EXIF Metadata provided by EXIF.tools