Section 3
Safety Switches
Light Duty
Fusible

3-2

Application Data and Dimensions

3-3

Standards:
•
•

UL 98 Enclosed and Dead Front Switches.
UL Listed under File E2875.
NEMA Standards Publication KS1. Enclosed Switches.

General Duty
Light Duty, p. 3-2

Fusible and Non-Fusible

3-2

Application Data and Dimensions

3-3

Standards:
•
•

UL 98 Enclosed and Dead Front Switches.
UL Listed under File E2875.
NEMA Standards Publication KS1. Enclosed Switches.

Heavy Duty
Fusible

3-4

Non-Fusible

3-6

Special Application Enclosures

3-7

Motor Disconnect and Receptacle Switches
General Duty, p. 3-2

3-8

Accessories

3-11

Application Data and Dimensions

3-13

Standards:
•
•
•

UL 98 Enclosed and Dead Front Switches.
UL Listed under files E2875, E154828, E233505 and E317818.
UL 508 Industrial Control Equipment, file E 164864.
NEMA Standards Publication KS1 Enclosed Switches (UL98 Switches Only).

Fusible and Non-Fusible

3-15

Accessories

3-18

Standards:
•
•
Heavy Duty, p. 3-4

UL 98 Enclosed and Dead Front Switches.
UL Listed under files E2875 (unless otherwise noted).
NEMA Standards Publication KS1 Enclosed Switches (applies to Type DT and
DTU series F only).

Application Data and Dimensions

1000 Vdc Photovoltaic Heavy Duty
Disconnect Switch

3-19
3-22

3

Standards:
•
•
•
•
•
•

UL 98 Enclosed and Dead Front Switches
UL Listed under file E343347
IEC 60947 - 1 Electrical
IEC 60947 - 3 Mechanical
NEMA standard. Publication KS-1 Enclosed Switches
IP 63 and NEMA 3 Enclosure

Stainless Steel Heavy Duty, p. 3-7

© 2012 Schneider Electric
All Rights Reserved

SAFETY SWITCHES

Double Throw

3-1

General Duty Safety Switches

Light Duty
Class 3130 / Refer to Catalog 3100CT0901
www.schneider-electric.us

Light Duty—Visible Blades 10 kA Short Circuit Current Rating
The Square D light duty enclosed switch is ideal for home applications in disconnecting power to workshops, hobby rooms,
furnaces, and garages.
Table 3.1:
System

L221N

Fusible

Amperes Fuse

NEMA 1 Indoor

Cat. No.
$ Price
2 Wire (1 Blade and Fuseholder, 1 Neutral)—120 Vac

30

a

Plug

L111N

Horsepower Ratings
Std.

Max.

1/2

2

$54.00

System

NEMA 1 Indoor

Amperes Fuse

Horsepower Ratings

Cat. No.
$ Price
Std.
3 Wire (2 Blades and Fuseholders, 1 Neutral)—120/240 Vac

Max.

30

Plug

L211N

72.00

1-1/2a

3a

30

Cart.

L221N

98.00

1-1/2a

3a

For single phase hp rating, use two switching poles.

General Duty—Up To 100 kA Short Circuit Current Rating With Proper Current Limiting Fusing
General duty safety switches are designed for residential and commercial applications where durability and economy are
prime considerations. Typical loads are lighting, air conditioning, and appliances. They are suitable for use as service
equipment when equipped with a factory- or field-installed neutral assembly or a field-installed service grounding kit, (see
Table 3.6) as applicable.
General duty safety switches are UL Listed, File E2875, and meet or exceed the NEMA Standard KS1.
D223N

Table 3.2:

Fusible

UL Listed Short Circuit
Withstand Rating
Short
Circuit
Rating
Plug
10 kA
H
10 kA
K
10 kA
Fusible
J
100 kA
R
100 kA
T
100 kA
H
10 kA
K
10 kA
NonJ
100 kA
Fusiblea
R
100 kAb
T
100 kA
a
The UL Listed short-circuit
current rating for
Square D general duty,
not fusible switches is
based on the switch being
used in conjunction with
fuses. Evaluation of nonfusible switches in
conjunction with molded
case circuit breakers
above 10,000 amps has
not been performed. For
applications requiring
greater protection,
consider using a heavy
duty safety switch. Refer
to UL Listed Maximum
Short Circuit Current
Ratings—AC only—on
page 3-6. If a UL Listed
short-circuit current rating
is required, this nonfusible switch must be
replaced with a Square D
general duty fusible safety
switch equipped with the
appropriate class and size
fusing. Consult the wiring
diagram of the switch to
verify the UL Listed shortcircuit current rating.
b
50 kA for 60 A non-fusible
switch.
Switch
Type

3
SAFETY SWITCHES

3-2

Fuse
Class

NEMA 1
Indoor
System

Amperes

NEMA 3Ra
Rainproof

Class R Fuse Kits
Field-Installedb

Fuse
Cat. No.

$ Price

Cat. No.

$ Price

Cat. No.

$ Price

2 Wire (1 Blade and Fuseholder, 1 Neutral)—120 Vac
30
Plug
Use Light Duty Device for this Application (see below)
30

Cart.

Use three-wire devices for this application.

Horsepower Ratings
Std. (Fast Acting
One-Time Fuses)

Max. (Dual Element
Time-Delay Fuses)

1Ø

3Ø

1Ø

3Ø

—

—

—

—

—

—

—

—

3 Wire (2 Blades and Fuseholders, 1 Neutral)—120/240 Vac (Plug), 240 Vac (Cart.) Maximum
30
Plug
D211N
90.00 D211NRB
177.00
—
—
1-1/2
—
3
—
30
Cart.
D221N
122.00 D221NRB
188.00
DRK30
25.65
1-1/2
3c
3
7-1/2c
60
Cart.
D222N
206.00 D222NRB
326.00 RFK03H
25.50
3
7-1/2c
10
15c
100
Cart.
D223N
426.00 D223NRB
480.00
RFK10
47.70
7-1/2
15 c
15
30c
200
Cart.
D224Ne
884.00 D224NRBe 1200.00 HRK1020
47.70
15
25 c
—
60c
400
Cart.
D225N
2555.00
D225NR
3459.00
DRK40
111.00
—
—
—
—
600g
Cart.
D226N
5109.00
D226NR
6569.00 DRK600
111.00
—
—
—
—
4 Wire (3 Blades and Fuseholders, 1 Neutral)—240 Vac Maximum
30
Cart.
D321N
188.00 D321NRB
293.00
DRK30
25.65
1-1/2
3
3
7-1/2
60
Cart.
D322N
326.00 D322NRB
441.00 RFK03H
25.50
3
7-1/2d
10
15d
100
Cart.
D323N
564.00 D323NRB
816.00
RFK10
47.70
7-1/2
15d
15
30d
200
Cart.
D324Ne
1202.00 D324NRBe 1461.00 HRK1020
47.70
15
25d
—
60d
400
Cart.
D325N
3113.00
D325NR
3893.00
DRK40
111.00
—
50
—
125
400f
Class T D325NT
2994.00 D325NTR
3741.00
—
—
—
50
—
—
600g
Cart.
D326N
5823.00
D326NR
7877.00 DRK600
111.00
—
75
—
150
600f
Class T D326NT
5598.00 D326NTR
7569.00
—
—
—
75
—
—
800f
Class T
T327N
9722.00
T327NR
12438.00
—
—
—
100
—
—
a
Bolt-on hubs—Refer to page 3-10.
b
When installed, this kit rejects all but Class R fuses.
c
For corner grounded delta systems only. Use switching poles for ungrounded conductors. See data bulletin 2700DB0202 for additional information.
d
If corner grounded delta, use outer switching poles for ungrounded conductors.
e
For 200% neutral, order (1) additional neutral kit SN20A and (1) neutral jumper kit SN20NI.
f
Class T 400–800 A general duty safety switches use 300 Vac Class T fuses and are UL Listed for use on systems with up to 100 kA available fault current.
g
Order Class J fuse kit: GDJK600 for Class J fuses.

Table 3.3:
System

Non-Fusible
Amperes

NEMA 3R Rainproof h

NEMA 1 Indoor
Cat. No.

$ Price

Cat. No.

$ Price

Horsepower Ratings (Max.)
1Ø

3Ø

2 Wire (2 Blades)—240 Vac Maximum
30
—
—
DU221RB
177.00
3
—
60
—
—
DU222RB
353.00
10
—
60
QO260NATSij
161.00
QO200TR ijk
161.00
10
—
100
QO2000NSij
276.00
QO2000NRBik
338.00
20
—
200
Use 3P Switch
—
Use 3P Switch
—
—
—
400p
Use 3P Switch
—
Use 3P Switch
—
—
—
600
Use 3P Switch
—
Use 3P Switch
—
—
—
3 Wire (3 Blades)—240 Vac Maximum
30
DU321
155.00
DU321RB
293.00
3
7-1/2
60
DU322
206.00
DU322RB
443.00
10
15
100
DU323l
477.00
DU323RBl
816.00
15
30
200
DU324m
884.00
DU324RBm
1461.00
15
60n
400p
DU325
2198.00
—
—
—
125
600
DU326n
4191.00
—
—
—
150
h
Bolt-on hubs—Refer to page 3-10.
i
Enclosed molded case switch—Refer to page 1-24.
j
Includes factory-installed grounding kit.
k
Not service entrance rated—Refer to page 1-19 for more information.
l
If a neutral assembly is required, order and field-install SN0610.
m
If a neutral assembly is required, order and field install a SN20A Neutral Assembly Kit. For a 200% neutral application, order and field install (2) SN20A
Neutral Assembly Kits and (1) SN20NI Neutral Jumper Kit.
n
If a neutral assembly is required, order part number D600SN. Available for field-installation.
o
For single phase hp rating, use two switching poles.
p
To accept J class fuses, move fuse bases to the embossed guide inside of the switch.

DE1A

DE2A

Discount
Schedule

© 2012 Schneider Electric
All Rights Reserved

General Duty Safety Switches

Accessories, Lug Data and Dimensions
Class 3130 / Refer to Catalog 3100CT0901

www.schneider-electric.us

Terminal Lug Data a

Table 3.4:

Table 3.6:

Wire Range
Amperes Conductors
Per NEC Table 312.6
Per Phase Wire Bending Space
AWG/kcmil
30
60
100
200

1
1
1
1
1
or
2

Lug Wire Range
AWG/kcmil

12–6 (Al) or 14–6 (Cu)
10–2 (Al) or 14–2 (Cu)
12–1/0 (Al) or 14–1/0 (Cu)
6 –300 (Al/Cu)
(1) 1/0 –750 (Al/Cu)
400
or
NEMA 1
(2) 1/0 –300 (Al/Cu)
(1) 1 –600 (Al/Cu)
400
2
1/0–250
(Al/Cu)
or
NEMA 3R
(2) 1/0 –250 (Al/Cu)
600
2
4 –500 (Al/Cu)
4 –600 (Al/Cu)
800
3
3/0 –500 (Al/Cu)
3/0 –500 (Al/Cu)
o
o
a
30–100 A switches suitable for 60 C or 75 C conductors. 200–800 A switches suitable for
75oC conductors.

Cat. No.

30

PK3GTA1

11.40

60a

PK3GTA1

11.40

60b

GTK03

11.40

12–6 (Al) or 14–6 (Cu)
10–3 (Al) or 14–3 (Cu)
12–1 (Al) or 14–1 (Cu)
6 –250 (Al/Cu)
1/0 –600 (Al/Cu)
or
1/0 –300 (Al/Cu)

a
b

NOTE: Field-installed lug kits are located in the Supplemental
Digest page 2.2.

Kit consists of three fuse pullers as required for a 3P, fusible, 60 and 100 A
general duty switch. Kits can be installed in 60 and 100 A Series F switches.
Table 3.5:
Fuse Puller Kits
Description

Cat. No.
FPK03
FPK0610

100
GTK0610
200
PKOGTA2
400
PKOGTA2
600
(Two Required)
800
PKOGTA3
Series E switch only.
Series F switch only.

$ Price

18.90
55.00
55.00
123.00

Wire Size (AWG)
(2) 12 Cu or
(2) 10 Al or
(1) 4 Al/Cu Max.
(2) 12 Cu or
(2) 10 Al or
(1) 4 Al/Cu Max.
(2) 12 Cu or
(2) 10 Al or
(1) 4 Al/Cu Max.
(2) 1/0 Al/Cu Max.
(2) 2/0 Al/Cu Max.
(2) 2/0 Al/Cu Max.
Per Lug
(6) 3/0 Al/Cu Max.

Field-Installed Electrical Interlock Kits

Field-Installed Fuse Puller Kits

Series F 60 A Fuse Puller Kit
Series F 100 A Fuse Puller Kit

Field-Installed Service Grounding Kits

Amperes

$ Price
30.00
42.60

W

Electrical interlocks for Series F 100–200 A general duty safety switches
and Series F 60 A fusible general duty safety switches are available in
kit form for field installation. Each kit contains instructions for proper field
mounting. A pivot arm operates from switch mechanism, breaking the
control circuit before the main switch blades break. Switches with
electrical interlocks installed are UL Listed.
Table 3.7:
Electrical Interlock Kit
Switch’s
Amperes Rating

Electrical Interlock Kit
$ Price
Cat. No.a
EIK031
or
60
Fb
218.00
EIK032
EIK1
or
100–200
F
311.00
EIK2
a
Electrical interlock kit catalog numbers with -1 suffix indicates one normally open and one
normally closed contact; -2 indicates two normally open and two normally closed contacts.
Kits are UL Listed.
b
Fusible series.
Series

H

W/H

H
W
W/H
D
Std.
Cat. No.
in.
mm
in.
mm
in.
mm
in.
mm Pack
L111N
E2
7.63
194
5.00 127
6.13 156 4.00 102
1
D325NTRc
L211N
E2
7.63
194
5.00 127
6.13 156 4.00 102
1
D326Nc
L221N
E2
7.63
194
5.00 127
6.13 156 4.00 102
1
D326NTc
D211Nc
E3
9.25
235
6.75 171
7.25 184
3.63
92
5
D326NRc
D211NRBc
E2
9.63
245
7.25 184
7.75 197
3.75
95
5
D326NTRc
D221Nc
E3
9.25
235
6.75 171
7.25 184
3.63
92
5
DU221RBc
D221NRBc
E3
9.63
245
7.25 184
7.75 197
3.75
95
5
DU222RBc
D222N
F1
14.63
372
6.50 165
7.45 189
4.88 124
1
DU321c
D222NRB
F1
14.88
378
6.63 168
7.45 189
4.88 124
1
DU321RBc
D223N
F3
17.50
445
8.50 216 10.50 267
6.50 165
1
DU322c
D223NRB
F3
17.50
445
8.50 216 10.50 267
6.50 165
1
DU322RBc
D224N
F1
29.00
737 17.25 438 19.00 483
8.25 210
1
DU323
D224NRB
F1
29.25
743 17.25 438 19.00 483
8.25 210
1
DU323RB
D225N
E3
45.12 1146 24.00 610 24.88 632
8.88 226
1
DU324
D225NR
E1
30.63
778 21.38 543 22.25 565 10.13 257
1
DU324RB
D226Nc
E3
49.13 1248 24.00 610 24.88 632
8.88 226
1
DU325c
D226NRc
E1
49.13 1248 24.75 629 25.13 638
8.88 226
1
DU326c
D321Nc
E3
9.25
235
6.75 171
7.25 184
3.63
92
5
QO200TRc
D321NRBc
E3
9.63
245
7.25 184
7.75 197
3.75
95
5
QO260NATSc
D322N
F1
14.63
372
6.50 165
7.45 189
4.88 124
1
QO2000NRBc
D322NRB
F1
14.88
378
6.63 168
7.45 189
4.88 124
1
QO2000NSc
D323N
F3
17.50
445
8.50 216 10.50 267
6.50 165
1
T327Nc
D323NRB
F3
17.50
445
8.50 216 10.50 267
6.50 165
1
T327NRc
D324N
F1
29.00
737 17.25 438 19.00 483
8.25 210
1
D324NRB
F1
29.25
743 17.25 438 19.00 483
8.25 210
1
D325Nc
E3
45.12 1146 24.00 610 24.88 632
8.88 226
1
D325NTc
E3
45.12 1146 24.00 610 24.88 632
8.88 226
1
D325NRc
E1
30.63
778 21.38 543 22.25 565 10.13 257
1
c
30–100 A switches suitable for 60oC or 75oC conductors. 200–800 A switches suitable for 75oC conductors.
Cat. No.

Series

© 2012 Schneider Electric
All Rights Reserved

DE1

DE3A

Discount
Schedule

Series
E1
E3
E3
E1
E1
E2
E1
E2
E2
E1
E1
F3
F3
F1
F1
E3
E3
G3
E2
E1
E1
E1
E1

H
in.
30.63
49.13
49.13
49.13
49.13
9.63
9.63
9.25
9.63
9.25
9.63
17.50
17.50
29.00
29.25
45.12
49.13
6.50
9.25
14.00
13.38
49.13
49.13

mm
778
1248
1248
1248
1246
245
245
235
245
235
245
445
445
737
743
1146
1248
165
235
356
340
1248
1248

W
W/H
D
Std.
in.
mm
in.
mm
in.
mm Pack
21.38 543 22.25 565 10.13 257
1
24.00 610 24.88 632
8.88 226
1
24.00 610 24.88 632
8.88 226
1
24.75 629 25.13 638
8.88 226
1
24.75 629 25.13 638
8.88 226
1
7.25 184
7.75 197
3.75
95
5
7.25 184
7.75 197
3.75
95
5
6.75 171
7.25 184
3.63
92
5
7.25 184
7.75 197
3.75
95
5
6.75 171
7.25 184
3.63
92
5
7.25 184
7.75 197
3.75
95
5
8.50 216 10.50 267
6.50 165
1
8.50 216 10.50 267
6.50 165
1
17.25 438 19.00 483
8.25 210
1
17.25 438 19.00 483
8.25 210
1
24.00 610 24.88 632
8.88 226
1
24.00 610 24.88 632
8.88 226
1
4.63 118
—
—
3.88
99
5
4.88 124
—
—
3.25
83
1
7.75 197
—
—
4.50 114
1
6.13 156
—
—
3.50
89
1
24.00 610 24.88 632
8.88 226
1
24.75 629 25.13 638
8.88 226
1

3-3

SAFETY SWITCHES

Approximate Dimensions

3

Table 3.8:

D

Heavy Duty Safety Switches

240 Volt
Class 3110 / Refer to Catalog 3100CT0901
www.schneider-electric.us

Visible blade heavy duty safety switches are designed for application where maximum
performance and continuity of service are required. All heavy duty safety switches
feature quick-make, quick-break operating mechanism, a dual cover interlock and a
color coded indicator handle. They are suitable for use as service equipment when
equipped with a field- or factory-installed neutral assembly or equipment grounding kit,
unless a 600Y/347 V or 480 Y/277 V, 1000 A or greater, solidly grounded WYE system
is used, per NEC 215-10. Heavy duty safety switches are UL Listed (except as noted),
File E2875 and 154828 and meet or exceed the NEMA Standard KS1. For UL Listed
short circuit current ratings, see page 3-6.

NEMA 3R NEMA 4, 4X and 5
Stainless Steel

NEMA 1

Table 3.9:

System

NEMA 12

240 Volt—Single Throw Fusible

Amperes

NEMA 1
Indoor

Cat. No.

$ Price

NEMA 3R
Rainproof
(Bolt-on Hubs,
page 3-10)
Cat. No.

$ Price

NEMA 4, 4X, 5, a
304 Stainless Steel (for
316 stainless, see
page 3-7) Dust tight,
Watertight, Corrosion
Resistant (Watertight
Hubs, page 3-10)
Cat. No.

$ Price

NEMA 12K
With
Knockouts
(Watertight Hubs,
page 3-10)
Cat. No.

$ Price

NEMA
12, 3R b
Without
Knockouts
(Watertight Hubs,
page 3-10)
Cat. No.

3
SAFETY SWITCHES

2-Wire (2 Blades and Fuseholders)—240 Vac, 250 Vdc
30
H221DS
1947.00 H221A
504.00
H221AWK
30
—
—
—
—
H2212AWKe
Use
three-wire
devices
60
H222DS
2337.00
—
—
H222AWK
For two-wire applications
100
H223DS
5094.00 H223A
1008.00
H223AWK
200
H224DS
6960.00 H224A
1737.00
H224AWK
400
H225
2729.00
H225R
3884.00
H225DS
14481.00
—
—
H225AWK
600
H226
5424.00
H226R
7281.00
H226DS
20772.00
—
—
H226AWK
800
H227
8459.00
H227Rf 11483.00
—
—
—
—
H227AWK
—
—
—
—
H228AWK
1200
H228 11682.00 H228Rf 15486.00
3-Wire (2 Blades and Fuseholders, 1 Neutral)—240 Vac, 250 Vdc
30
H221N
236.00 H221NRB
447.00
Use two-wire devices,
60
H222N
471.00 H222NRB
842.00
Field-installed solid neutral assemblies
100
H223N
716.00 H223NRB
1086.00
Order separately See page 3-11.
200
H224N
1289.00 H224NRB
1562.00
400
H225N
3092.00
H225NR
4245.00 H225NDS 14787.00
—
—
H225NAWK
600
H226N
5819.00
H226NR
7677.00 H226NDS 21081.00
—
—
H226NAWK
800
H227N 10067.00 H227NRf 12216.00
—
—
—
—
H227NAWK
1200
H228N 12422.00 H228NRf 16665.00
—
—
—
—
H228NAWK
3-Wire (3 Blades and Fuseholders)—240 Vac, 250 Vdc
30
H321DS
2049.00 H321A
639.00
H321AWK
60
H322DS
2532.00 H322A
914.00
H322AWK
Use four-wire devices
For three-wire applications
100
H323DS
5346.00 H323A
1412.00
H323AWK
200
H324DS
7496.00 H324A
2040.00
H324AWK
400
H325
3425.00
H325R
3975.00
H325DS
14961.00
—
—
H325AWK
600
H326
6170.00
H326R
8286.00
H326DS
21399.00
—
—
H326AWK
800
H327 11456.00 H327Rf 14849.00
—
—
—
—
H327AWK
1200
H328 14517.00 H328Rf 18728.00
—
—
—
—
H328AWK
4-Wire (3 Blades and Fuseholders, 1 Neutral)—240 Vac, 250 Vdc
30
H321N
314.00 H321NRB
555.00
Use three-wire devices,
60
H322N
528.00 H322NRB
891.00
Field-installed solid neutral assemblies
100
H323N
842.00 H323NRB
1278.00
Order separately. See page 3-11
200
H324N
1451.00 H324NRB
1748.00
400
H325N
3788.00
H325NR
4322.00 H325NDS 15321.00
—
—
H325NAWK
600
H326N
6519.00
H326NR
8622.00 H326NDS 21759.00
—
—
H326NAWK
800
H327N 12189.00 H327NRf 15563.00
—
—
—
—
H327NAWK
1200
H328N 15314.00 H328NRf 19709.00
—
—
—
—
H328NAWK
4-Wire (4 Blades and Fuseholders)
30
60
100
Use 600 Vac devices. See page 3-5.
200
400
600
a
Complete rating is NEMA 3, 3R, 4, 4X, 5 and 12. For NEMA 3R applications, remove drain screw from bottom endwall.
b
Also suitable for NEMA 3R application by removing drain screw from bottom endwall.
c
For switching dc, use two outside switching poles.
d
For corner grounded delta systems only and with neutral assembly installed. Use switching poles for ungrounded conductors.
e
60 ampere switch with 30 ampere fuse spacing and clips. Must use 60 A enclosure accessories including electrical interlocks.
f
Suitable for NEMA 5 applications with drain screw installed.

Horsepower Ratings
240 Vac
Std.
(Using Fast
Acting,
One Time Fuses)

Max.
(Using Dual
Element, Time 250 Vdcc
Delay Fuses)

$ Price

1Ø

3Ø

1Ø

3Ø

473.00
588.00
647.00
948.00
1643.00
4163.00
6543.00
10325.00
15815.00

1-1/2
1-1/2
3
7-1/2
15
—
—
50
50

3d
—
7-1/2 d
15 d
25 d
—
75 d
—
—

3
3
10
15
—
—
—
50
50

7-1/2d
—
15 d
30 d
60 d
—
200 d
—
—

5
5
10
20
40
50
50
50
50

4304.00
6936.00
12338.00
17184.00

1-1/2
3
7-1/2
15
—
—
50
50

3 d
7-1/2 d
15 d
25 d
50 d
75 d
—
—

3
10
15
—
—
—
50
50

7-1/2 d
15 d
30 d
60 d
125 d
200 d
—
—

5
10
20
40
50
50
50
50

639.00
864.00
1331.00
1926.00
4253.00
7365.00
14528.00
17450.00

1-1/2
3
7-1/2
15
—
—
50
50

3
7-1/2
15
25
50
75
100
100

3
10
15
—
—
—
50
50

7-1/2
15
30
60
125
200
250
250

5
10
20
40
50
50
50
50

4635.00
7757.00
15879.00
20015.00

1-1/2
3
7-1/2
15
—
—
50
50

3
7-1/2
15
25
50
75
100
100

3
10
15
—
—
—
50
50

7-1/2
15
30
60
125
200
250
250

5
10
20
40
50
50
50
50

Accessories: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . pages 3-10 through 3-12
Dimensions: NEMA 1 and 3R . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 3-13
Dimensions: NEMA 4, 4X and 5 Stainless and NEMA 12 . . . . . . . page 3-14

3-4

DE1

Discount
Schedule

© 2012 Schneider Electric
All Rights Reserved

Heavy Duty Safety Switches

600 Volt
Class 3110 / Refer to Catalog 3100CT0901

www.schneider-electric.us

Table 3.10:

600 Volts—Single Throw Fusible
Horsepower Ratings

System

NEMA 1
Indoor

Amperes

Cat. No.

$ Price

NEMA 3R
Rainproof
(Bolt-on Hubs,
page 3-10)

Cat. No.

$ Price

NEMA 4, 4X, 5a
304 Stainless Steel
NEMA 12K
(for 316 stainless, see
With Knockouts
page 3-7) Dust tight,
(Watertight
Hubs,
Watertight, Corrosion
page 3-10)
Resistant
(Watertight Hubs, page 3-10)
Cat. No.

$ Price

Cat. No.

$ Price

480 Vac
NEMA 12, 3Rb
Without Knockouts
(Watertight Hubs,
page 3-10)

Cat. No.

600 Vac

Max.
Std.
Max.
Std.
(Using (Using (Using
(Using
Dual
Fast
Dual
Fast
Acting, Element,
Acting, Element,
Time
One
Time
One Time Delay
Time
Delay
Fuses)
Fuses) Fuses) Fuses)

dcd

$ Price

3Ø

3Ø

3Ø

3Ø

250 600

5025.00
7341.00
15276.00
18044.00

—
—
—
—
100 c
150 c
—
—

—
—
—
—
250 c
400 c
—
—

—
—
—
—
—
—
—
—

—
—
—
—
—
—
—
—

—
—
—
—
50
50
50
50

—
—
—
—
50
50
50
50

5
5
15
25
50
100
150
200
200

15
15
30
60
125
250
400
500
500

7-1/2
7-1/2
15
30
60
125
200
250
250

20
20
50
75
150
350
500
500
500

5
—
—
—
40
50
50
50
50

15
15
30
50
50
50
50
50
50

5
15
25
50
100
150
200
200

15
30
60
125
250
400
500
500

7-1/2
15
30
60
125
200
250
250

20
50
75
150
350
500
500
500

—
—
—
40
50
50
50
50

15
30
50
50
50
50
50
50

2Ø
7-1/2
15
25
50
100
150
3Ø
25

2Ø
20
40
50
—
250
400
3Ø
60

2Ø
10
20
30
50
125
200
3Ø
30

2Ø
25
50
75
—
350
500
3Ø
75

5
10
20
40
50
50

15
30
30
50
50
50

—

—

2-Wire (2 Blades and Fuseholders)—600 Vac, 600 Vdc
30
60
100
200
400
600
800
1200

Use three-wire devices
for two-wire applications
H265
H266
H267
H268

4206.00
6653.00
10365.00
14570.00

H265R
5424.00
H266R 10686.00
H267Rf 16385.00
H268Rf 17991.00

H265DS
H266DS
—
—

14961.00
21399.00
—
—

—
—
—
—

—
—
—
—

H265AWK
H266AWK
H267AWK
H268AWK

3-Wire (3 Blades and Fuseholders)—600 Vac, 600 Vdc d
30
30
60
100
200
400
600
800
1200

H361
H361-2f
H362
H363
H364
H365
H366
H367
H368

528.00 H361RB
899.00
617.00 H3612RBe 1049.00
638.00 H362RB
1055.00
1188.00 H363RB
1644.00
1707.00 H364RB
2259.00
4551.00
H365R
5532.00
7649.00
H366R 10899.00
13319.00 H367R f 16500.00
17507.00 H368Rf 20009.00

H361DS
—
H362DS
H363DS
H364DS
H365DS
H366DS
—
—

2520.00
H361A
—
H361-2A e
2771.00
H362A
5493.00
H363A
7685.00
H364A
15321.00
—
21084.00
—
—
—
—
—

1014.00
H361AWK
956.00
1035.00 H3612AWKe
977.00
1047.00
H362AWK
984.00
1626.00
H363AWK
1539.00
2544.00
H364AWK
2400.00
—
H365AWK
5462.00
—
H366AWK
9203.00
—
H367AWK 16352.00
—
H368AWK 19706.00

4-Wire (3 Blades and Fuseholders, 1 Neutral)—600 Vac, 600 Vdcd
H361N
617.00 H361NRB
986.00
H362N
710.00 H362NRB 1134.00
H363N 1278.00 H363NRB 1737.00
H364N 1869.00 H364NRB 2408.00
H365N 4898.00 H365NR 5765.00
H366N 8019.00 H366NR 11054.00
H367N 14043.00 H367NRf 17205.00
H368N 18114.00 H368NRf 20993.00

Use three-wire devices field-installed solid neutral
assemblies. Order separately. See page 3-11.
H364NDS
H365NDS
H366NDS
—
—

7871.00
15668.00
22122.00
—
—

H364NA
—
—
—
—

2715.00
—
—
—
—

H364NAWK 2558.00
H365NAWK 5823.00
H366NAWK 9600.00
H367NAWK 17253.00
H368NAWK 20820.00

H461DS
H462DS
H463DS
H464DS
—
—

2937.00
3069.00
8345.00
12596.00
—
—

—
—
—
—
—
—

—
—
—
—
—
—

H461AWK
H462AWK
H463AWK
H464AWK
H465AWK
—

4-Wire (4 Blades and Fuseholders)—600 Vac, 600 Vdcg
30
60
100
200
400
600

H461
H462
H463
H464
H465
H466

914.00
1065.00
1778.00
2957.00
6210.00
10104.00

—
—
—
—
—
—

—
—
—
—
—
—

1115.00
1257.00
1932.00
3222.00
6807.00
—

6-Wire (6 Blades and Fuseholders)—600 Vac g

a
b
c
d
e
f
g

100

—

—

—

—

H663DS

25964.00

—

—

H663AWK

200

—

—

—

—

H664DS

35393.00

—

—

H664AWK

5112.00

For applications requiring motor disconnect
12222.00 capability,
use electrical interlock. Refer to page 3-10.

Complete rating is NEMA 3, 3R, 4, 4X, 5 and 12.
Also suitable for NEMA 3R application by removing drain screw from bottom endwall.
For corner grounded delta systems only and with neutral assembly installed. Use switching poles for ungrounded conductors.
For switching dc use two outside switching poles.
60 A switch with 30 A fuse spacing and clips. Must use 60 A enclosure accessories including electrical interlocks.
Suitable for NEMA 5 applications with drain screw installed.
Not suitable for use as service equipment.

Class H Fuse Provisions:
Fusible Square D 30 through 600 A heavy duty safety switches accept Class H fuses as standard. With Class H fuses
installed, the switch is UL Listed for use on systems with up to 10 kA available fault current.

SAFETY SWITCHES

30
60
100
200
400
600
800
1200

Fusible Square D 30–600 A heavy duty safety switches will accept Class R fuses as standard. A field-installed rejection
kit is available which, when installed, rejects all but Class R fuses. With the installation of the rejection kit and Class R
fuses, the switch is UL Listed for use on systems with up to 200 kA available fault current. See Class R fuse kits on
page 3-10.

Class J Fuse Provisions:

Class R Fuse

Provisions for installing Class J fuses are included in 30 through 400 A 600 Volt, and 100 through 400 A 240 Volt,
fusible heavy duty safety switches. Conversion to Class J fuse spacing requires relocating the load side fuse base
assembly from the standard Class H fuse location to an alternate position as marked in the enclosure. With Class J
fuses installed, the switch is UL Listed for use on systems with up to 200 kA available fault current. Switches rated
600 A, 240 or 600 Volt, require the addition of an adapter kit, H600J at $456. One kit per 3P switch.

Class L Fuse Provisions:
Fusible 800 A and 1200 A safety switches use Class L bolt-in fuses and are rated for use on systems with up to 200 kA
at 600 Vac maximum. 1200 A switches accept class L fuses from 601–1200 A, 800 A switches accept class L fuses
from 601–800 A.
Accessories: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .pages 3-10 through 3-12
Dimensions: NEMA 1 and 3R . . . . . . . . . . . . . . . . . . . . . . . . . . . . .page 3-13
Dimensions: NEMA 4, 4X and 5 . . . . . . . . . . . . . . . . . . . . . . . . . . .page 3-14

© 2012 Schneider Electric
All Rights Reserved

DE1

Discount
Schedule

3-5

3

Class R Fuse Provisions:

Heavy Duty Safety Switches
Refer to Catalog 3100CT0901
www.schneider-electric.us

Table 3.11:

System

600 Volt—Single Throw Non-Fusible

NEMA 1
Indoor

Amperes

Cat. No.

$ Price

2-Wire (2 Blades)—600 Vac, 600 Vdc
30
60
100
200
400
HU265
2750.00
600
HU266
4896.00
800
HU267
7467.00
1200
HU268 10226.00

NEMA 4, 4X, 5 a
304 Stainless Steel
(for 316 stainless, see
page 3-7)
Dust tight, Watertight
Corrosion Resistant
(Watertight Hubs, page 3-10)

NEMA 3R
Rainproof
(Bolt-on Hubs, page 3-10)

Cat. No.

$ Price

Cat. No.

$ Price

NEMA 12K
With
Knockouts
(Watertight Hubs,
page 3-10)
Cat. No.

$ Price

NEMA 12, 3Rb
Without
Knockouts
(Watertight Hubs,
page 3-10)
Cat. No.

$ Price

Use three-wire devices
for two-wire applications.
HU265R
HU266R
HU267Rd
HU268Rd

3764.00
7533.00
12884.00
17393.00

HU265DS
HU266DS
—
—

12812.00
18455.00
—
—

—
—
—
—

—
—
—
—

HU265AWK
HU266AWK
HU267AWK
HU268AWK

3
SAFETY SWITCHES

3-Wire (3 Blades)—600 Vac, 600 Vdc
30
HU361
279.00
HU361RB
488.00
HU361DS
2120.00
HU361A
689.00
HU361AWK
30 HU361EIe 638.00 HU361RBEIe
846.00 HU361DSEIe
2480.00 HU361AEIe 1047.00 HU361AWKEIe
30 HU3612f
369.00 HU3612RBf
638.00
—
— HU3612Af
710.00 HU3612AWKf
60
HU362
488.00
HU362RB
876.00
HU362DS
2520.00
HU362A
875.00
HU362AWK
60
—
—
—
—
HU362DSEIe
2972.00
—
—
—
100
HU363
783.00
HU363RB
1226.00
HU363DS
5102.00
HU363A
1265.00
HU363AWK
200
HU364
1209.00
HU364RB
1485.00
HU364DS
6960.00
HU364A
1697.00
HU364AWK
400
HU365
2804.00
HU365R
3840.00
HU365DS
14294.00
—
—
HU365AWK
600
HU366
4992.00
HU366R
7683.00
HU366DS
19062.00
—
—
HU366AWK
800
HU367
9978.00 HU367R d 13050.00
—
—
—
—
HU367AWK
1200
HU368 13421.00 HU368R d 17867.00
—
—
—
—
HU368AWK
4-Wire (4 Blades)—600 Vac, 600 Vdc j
30
HU461g
827.00
—
—
HU461DS
2586.00
—
—
HU461AWKh
60
HU462g
914.00
—
—
HU462DS
3027.00
—
—
HU462AWK
100
HU463g 1647.00
—
—
HU463DS
7401.00
—
—
HU463AWK
200
HU464g 2399.00
—
—
HU464DS
11244.00
—
—
HU464AWK
400
HU465
5201.00
—
—
—
—
—
—
HU465AWK
600
HU466
9072.00
—
—
—
—
—
—
—
6-Wire (6 Blades)—600 Vacj
30
—
—
—
—
HU661DS
11903.00
—
—
HU661AWKk
60
—
—
—
—
HU662DS
13254.00
—
—
HU662AWKk
100
—
—
—
—
HU663DS
20643.00
—
—
HU663AWKk
200
—
—
—
—
HU664DS
28316.00
—
—
HU664AWKk
a
Complete rating is NEMA 3, 3R, 4, 4X, 5 and 12.
b
Also suitable for NEMA 3R application by removing drain screw from bottom endwall.
c
For switching dc, use two outside switching poles.
d
Suitable for NEMA 5 applications with drain screw installed.
e
Switches with EI suffix are stocked with factory-installed electrical interlocks with one normally-open and one normally-closed contact.
f
Use 60 A enclosure accessories, including electrical interlocks.
g
No knockouts are provided.
h
Requires 60 A accessories. See page 3-14 for series rating..
i
HU461AWK (Series F6) is rated 5 hp@250 Vdc, 10 hp@600 Vdc.
j
Not suitable for use as service equipment.
k
One enclosure for NEMA 1, 3, 3R or 12 applications. UL Listed.

3212.00
5408.00
12957.00
17522.00
647.00
1007.00
666.00
833.00
—
1194.00
1604.00
4023.00
6711.00
13097.00
17940.00

Horsepower Ratings
(Max.)
Volts ac
240

480

600

dcc

1Ø 3Ø

1Ø

3Ø 1Ø 3Ø 250 600

—
—
—
—
—
—
50
50

—
—
—
—
—
—
50
50

—
—
—
—
—
—
—
—

915.00
1008.00
1791.00
2832.00
5672.00
—

5
5
5
10
10
20
15
—
—
50
50
2Ø
10
20
30
50
—
—

3357.00
3884.00
4793.00
10538.00

—
—
—
—

—
—
—
—
—
—
—
—

—
—
—
—
—
—
50
—

—
—
—
—
—
—
—
—

—
—
—
—
50
50
—
50

—
—
—
—
50
50
50
50

10 7-1/2 20 10 30 5 15
10 7-1/2 20 10 30 5 15
10 7-1/2 20 10 30 5 15
20 25
50 30 60 10 30
20 25
50 30 60 10 30
40 40
75 40 100 20 50
60 50 125 50 150 40 50
125 — 250 — 350 50 50
200 — 400 — 500 50 50
250 50 500 50 500 50 50
250 50 500 50 500 50 50
3Ø 2Ø 3Ø 2Ø 3Ø
10 20
20 25 30 10i 15i
20 40
50 50 60 10 30
40 50
75 50 75 20 30
60 50 125 50 150 40 50
125 — 250 — 350 50 50
200 — 400 — 500 50 50
3Ø
3Ø
3Ø
10 —
20 — 30 — —
20 —
50 — 60 — —
40 —
75 — 75 — —
60 — 125 — 150 — —

UL Listed Maximum Short Circuit Current Ratings—AC only
NOTE: Consult the wiring diagram of the switch to verify the
UL Listed short circuit current rating.

Table 3.12:

Non-Fusible Safety Switches

Fusible Safety Switches

For the short circuit current rating, refer to the table below.
Heavy Duty
Safety Switch Type

l

UL Listed
UL Listed Short Circuit
Fuse Class
Current Ratings
H, K
10 kA
Fusible
R, J, L
200 kAl
On 600 V, 200 A switches, 100,000 A max. on corner grounded delta when protected by
Class J or R fuses.

Any brand of circuit breaker or fuse not exceeding the ampere rating of the
switch may be used in conjunction with an non-fusible safety switch when
there is up to 10 kA short circuit current available (see table below).
Above 10 kA—When applied on systems with greater than 10 kA short
circuit current available, the UL Listed short circuit current rating for
Square D non-fusible switches is based upon the switch being used in
conjunction with fuses or Square D circuit breakers or Mag-Gard motor
circuit protectors.
Table 3.13:

Non-Fusible Safety Switches

Heavy Duty
Switch Rating
Safety Switch Type
(A) m

Fuse or Circuit
Breaker Typen

3-Phase

480 Vac
600 Vac
Any brand circuit
breaker
Up to 10 kA
All
H, K
R,T,J.L
200 kA
200 kA
200 kA
30–100
Ho
65 kA
35 kA
35 kA
Non-Fusible
Switches
30–100
FA
14 kA
14 kA
14 kA
30–100
FH
18 kA
18 kA
18 kA
200
H, J o
65 kA
35 kA
35 kA
400
LA
22 kA
22 kA
22 kA
400
LH
25 kA
25 kA
25 kA
m
Applies to NEMA 1, 3R, 4X stainless, 12 switches.
n
Ampere rating of fuse or circuit breaker not to exceed switch ampere rating.
o
All H and J circuit breakers are acceptable, but will only support the noted Short Circuit
Current Ratings.

3-6

DE1

Discount
Schedule

240 Vac

© 2012 Schneider Electric
All Rights Reserved

Heavy Duty Safety
Switches

Special Applications
Class 3110 / Refer to Catalog 3100CT0901

www.schneider-electric.us

316 Grade Stainless Steel—NEMA 3, 3R, 4, 4X, 5, 12
Type 316 stainless steel enclosure safety switches offer superior corrosion resistance to a wider range of chemicals than
Type 304 stainless switches. Type 316 better resists chloride and is often used in marine, waste treatment and transportation
applications. Use watertight hubs from page 3-10. Equipment grounding lugs are supplied as standard.
(For Type 304 stainless switches see pages 3-4–3-6.)
Table 3.14:

3P 600 Vac, 600 Vdc
Horsepower Ratings– 3Øa

Amperes

Cat. No

$ Price

480 Vac

600 Vac

600 Vdcb

Std.

Max.

Std.

Max.

Max.

Fusible

H361SS

30
60
100
200
400
600
Non-Fusible
30
60
100
200
400
600

H361SS
H362SS
H363SS
H364SS
H365SS
H366SS

3444.00
3792.00
7562.00
10592.00
21622.00
30528.00

5
15
25
50
100
150

15
30
60
125
250
400

7-1/2
15
30
60
125
200

20
50
75
150
350
500

15
30
50
50
50
50

HU361SS
HU362SS
HU363SS
HU364SS
HU365SS
HU366SS

2898.00
3444.00
7029.00
9623.00
17758.00
26306.00

—
—
—
—
—
—

20
50
75
125
250
400

—
—
—
—
—
—

30
60
100
150
350
500

15
30
50
50
50
50

Fiberglass Reinforced Polyester Enclosures—NEMA 4X
Fiberglass reinforced polyester enclosures are watertight, corrosion resistant, and impervious to windblown dust, rain, and
splashing liquid. The molded fiberglass is extremely stable in a wide range of operating temperatures and can withstand
heavy impact. Switches are furnished with hubs (page 3-14) and equipment grounding lugs. UL Listed.
Table 3.15:
Amperes

H363DF

Fusible
30
60
100
200
Non-Fusible
30
60
100
200

3P 600 Vac, 600 Vdc
Cat. No.

$ Price

Cat. No.

$ Price

H361DF
H362DF
H363DF
H364DF

3570.00
3968.00
7613.00
9729.00

RFK06
RFK06H
RFK10
HRK1020

HU361DF
HU362DF
HU363DF
HU364DF

3402.00
3782.00
7241.00
9695.00

—
—
—
—

Horsepower Ratings– 3Øa

Electrical Interlock Kits
Field-Installed Cat. No.

Class R Fuse Kits

480 Vac

600 Vac

600 Vdcb

1 NO/1 NC Contacts

2 NO/2 NC Contacts

Std.

Max.

Std.

Max.

Max.

25.50
25.50
47.70
47.70

9999TC10
9999TC10
9999TC10
9999R8

9999TC20
9999TC20
9999TC20
9999R9

5
15
25
50

15
30
60
125

7-1/2
15
30
60

20
50
75
150

15
30
50
50

—
—
—
—

9999TC10
9999TC10
9999TC10
9999R8

9999TC20
9999TC20
9999TC20
9999R9

—
—
—
—

20
50
75
125

—
—
—
—

30
60
100
—

15
30
50
50

Krydon™ Enclosures—NEMA 4X
Krydon enclosures are compression molded of fiberglass reinforced polyester, specially formulated to withstand attack from
almost any corrosive atmosphere found in the toughest industrial application. Switches are furnished with hubs
(page 3-14) and equipment grounding lugs. UL Listed.

Amperes

3P, 600 Vac, 600 Vdc
Cat. No.

$ Price

Cat. No.

H361DX

Fusible
30
60
100
Non-Fusible
30
60
100

Electrical Interlock Kits
Field-Installed Cat. No.

Class R Fuse Kits

H361DX
H362DX
H363DX

4161.00
4626.00
8858.00

RFK06
RFK06H
RFK10

HU361DX
HU362DX
HU363DX

3960.00
4406.00
8438.00

—
—
—

$ Price

Horsepower Ratings– 3Øa
480 Vac

600 Vac

600 Vdcb

1 NO/1 NC Contact

2 NO/2 NC Contacts

Std.

Max.

Std.

Max.

Max.

25.50
25.50
47.70

9999TC10
9999TC10
9999TC10

9999TC20
9999TC20
9999TC20

5
15
25

15
30
60

7-1/2
15
30

20
50
75

15
30
50

—
—
—

9999TC10
9999TC10
9999TC10

9999TC20
9999TC20
9999TC20

—
—
—

20
50
75

—
—
—

30
60
100

15
30
50

SAFETY SWITCHES

Table 3.16:

An enclosed automatic molded case switch for use in Divisions 1 and 2 of the following: Class I, Groups C and D; Class II,
Groups E, F and G; or Class III, Hazardous Locations as defined in NEC™ Article 500. Furnished with threaded conduit
openings in both top and bottom endwall (page 3-14). Suitable for use as service equipment and listed as “Raintight’’ for
outdoor applications. cULus Listed. Equipment grounding lugs supplied as standard.
Table 3.17:
Amperes

H60XFA
a
b
c
d
e
f

© 2012 Schneider Electric
All Rights Reserved

3 Pole Molded Case Switch, 600 Vac, 250 Vdc Maximum, Short Circuit Current Rating 10 kA AIR
Enclosed Molded Case Switchc

Solid Neutral Assembly

Cat. No.
$ Price
Cat. No.
60
H60XFA
2571.00
100SNA
60
H60XFA1212d
2886.00
100SNA
100
H100XFA
3045.00
100SNA
100
H100XFA1212d
3287.00
100SNA
225
H225XJGf
6387.00
225SNA
225
H225XJGAAdf
6701.00
225SNA
Std.—Using fast acting one time fuses. Max.—Using dual element time delay fuses.
For switching dc use two switching poles.
Includes PKDB1, breather and drain kit, required for rainproof application—NEMA 7 only.
Includes auxiliary contacts.
For available options, contact customer service prior to placing an order.
Not UL listed or CSA Certified due to wire bending space.

DE1

Discount
Schedule

Horsepower Ratings—3Ø
$ Price
143.00
143.00
143.00
143.00
189.00
189.00

240 Vac
15
15
30
30
60
60

480 Vac
30
30
60
60
125
125

600 Vacb
50
50
75
75
150
150

3-7

3

NEMA 7 and 9

UL508 Motor Disconnect
Switches

MD Motor Disconnect Switches
Class 3110 / Refer to Catalog 3100CT0901
www.schneider-electric.us

The MD motor disconnect switch is listed UL508 Suitable For Motor Control (UL File
E164864). It is in a compact NEMA 4X enclosure suitable for use in NEMA Type 1, 3, 3R, 4,
4X and 12 applications. The MD's key benefits are an extremely small footprint, a more
economically efficient NEMA 4X solution and a handle interlock preventing cover removal
when the switch is in the ON position.
Table 3.18:

MD Motor Disconnect Switch—Non Metallic NEMA 1, 3, 3R, 4, 4X and
12 Enclosureabc
Maximum Horse Power Ratings

Amperes

a
b
c

Cat. No.

$ Price

Height
(in.)

220–240
440–480
600
30
MD3304X
7.5
20
25
121.00
6.38
60
MD3604X
20
40
40
161.00
8.27
See table 8.9 for accessories.
Complies with OSHA lockout/tagout requirements—accepts up to three 8 mm padlocks.
Suitable for NEMA 1, 3R, 4, 4X and 12 enclosure applications.

Table 3.19:
D

Three Phase Vac

Cat. No.
MDSAN20
MDSAN11
MDS30P

Width
(in.)

Depth
(in.)

3.9
4.94

4.37
4.37

MD Motor Disconnect Accessories
Description
2 Normally open auxiliary contact module
1 normally open and 1 normally closed auxiliary contact module
30 Amp Add on power pole

$ Price
57.00
27.00
35.00

H

W

MD Motor Disconnect Switches

3
SAFETY SWITCHES

3-8
DE1

Discount
Schedule

© 2012 Schneider Electric
All Rights Reserved

Heavy Duty Safety Switches

Receptacle Switches
Class 3110 / Refer to Catalog 3100CT0901

www.schneider-electric.us

Interlocked Receptacle Switches
Interlocked Receptacle Switches are furnished with a factory-installed three-phase four-wire Appleton
Powertite™, Crouse-Hinds Style 2 Arktite™, or Hubbellock™ receptacle. The fourth wire is connected to the switch
equipment grounding terminal and is not a neutral termination. Interlocking linkage between the receptacle and
switch mechanism prevents insertion or removal of the plug while the switch is in the “ON’’ position or insertion of
any plug other than specified. Grounding lugs are included.

Appleton Powertite Receptacle

•
•
•

Devices are UL Listed and CSA Certified, suitable for use as service equipment.
Receptacles are epoxy powder coated over copper-free cast aluminum and NEMA 3, 3R, 4, 4X and 12 rated. Appleton receptacles
are UL Classified for use with the Crouse-Hinds plugs listed below.
Short circuit rating: 10 kA when used in conjunction with Class H or K fuses; 200 kA when used in conjunction with Class R or J fuses.
NEMA
3, 3R, 4, 4X, 5, 12
304 Stainless Steel
Enclosure

NEMA 1
Amperes
Cat. No.

H362AWA
Interlocked Receptacle
Switch with Appleton
Powertite Receptacle

$ Price

Cat. No.

$ Price

Cat. No.

Horsepower
Ratings–3Øb

Use with Plug a

NEMA 12, 3R

$ Price

Cat. No.

480 Vac

$ Price

600 Vac

250 Vdcc

Std. Max. Std. Max. Std. Max.

Fusible—3P, 600 Vac, 250 Vdc
30
H361WA
2076.00
H361DSWA
4401.00
H361AWA
2289.00
ACP3034BC
1235.00
5
15 7-1/2 20
5
60
H362WA
2412.00
H362DSWA
4668.00
H362AWA
2508.00
ACP6034BC
1295.00 15
30
15
50
10
100
H363WA
3689.00
H363DSWA
8468.00
H363AWA
3758.00
ACP1034CD
1928.00 25
60
30
75
20
Non-Fusible—3P, 600 Vac, 250 Vdc
30
HU361WA 1893.00 HU361DSWA 4001.00 HU361AWA 2076.00
ACP3034BC
1235.00 —
20
—
30
—
60
HU362WA 2306.00 HU362DSWA 4412.00 HU362AWA 2357.00
ACP6034BC
1295.00 —
50
—
60
—
100
HU363WA 3153.00 HU363DSWA 8010.00 HU363AWA 3347.00
ACP1034CD
1928.00 —
75
—
100
—
a
Receptacle UL Listed for use with “Appleton ACP or CPH” plugs; UL Classified for use with Crouse-Hinds “APJ” Arktite plugs listed on this page.
b
Std.—Using fast acting one time fuses. Max.—Using dual element time delay fuses.
c
For switching dc, use two switching poles.

—
—
—
5
10
20

Crouse-Hinds Arktite Receptacle

•
•

UL Listed, suitable for use as service equipment.
Short circuit ratings: 10 kA when used in conjunction with Class H or K fuses; 200 kA when used in conjunction with Class R or J fuses.

Table 3.20:

Amperes
Cat. No.

H362AWC
Interlocked Receptacle
Switch with Crouse-Hinds
Arktite Receptacle

$ Price

Cat. No.

$ Price

NEMA 12, 3R

Cat. No.

Horsepower
Ratings–3Ød

Use with Plug

$ Price

Fusible—3P, 600 Vac Maximum
30
H361WC
2139.00
H361DSWC
6377.00
H361AWC
2355.00
60
H362WC
2751.00
H362DSWC
7749.00
H362AWC
2846.00
100
H363WC
6005.00
H363DSWC
14826.00
H363AWC
6087.00
Non-Fusible—3P, 600 Vac Maximum
30
HU361WC
1952.00 HU361DSWC
5888.00
HU361AWC
2136.00
60
HU362WC
2634.00 HU362DSWC
7374.00
HU362AWC
2678.00
100
HU363WC
5249.00 HU363DSWC
14025.00
HU363AWC
5444.00
d
Std.—Using fast acting one time fuses. Max.—Using dual element time delay fuses.

Cat. No.

$ Price

480 Vac

600 Vac

Std.

Max.

Std.

Max.

APJ3485
APJ6485
APJ10487

1235.00
1295.00
1928.00

5
15
—

15
30
60

7-1/2
15
—

20
50
75

APJ3485
APJ6485
APJ10487

1235.00
1295.00
1928.00

—
—
—

20
50
60

—
—
—

30
60
100

Hubbellock Receptacle

•
•

UL Listed, suitable for use as service equipment.
Short circuit rating: 10 kA.

Note: The Hubbellock receptacle switch utilizes the Square D interlocked plug SD12781 available only from Square D.

SAFETY SWITCHES

NEMA 3, 3R, 4, 4X, 5, 12
304 Stainless Steel
Enclosure

NEMA 1

Table 3.21:

Cat. No.

$ Price

NEMA 12
Cat. No.

$ Price

Use with Plug
Cat. No.

$ Price

Fusible—3P, 600 Vac Maximum
60
H362WH
2351.00 H362AWH
2459.00 SD12781f
609.00
Non-Fusible—3P, 600 Vac Maximum
60
HU362WH
2237.00 HU362AWH
2310.00 SD12781f
609.00
e
Std.—Using fast acting one time fuses. Max.—Using dual element time delay fuses.
f
Hubbell plug is furnished with a Kellems grip for 1-1/2 in. to 1-21/64 in. cable diameter.

Horsepower Ratings—3Øe
480 Vac

600 Vac

3

NEMA 1
Amperes

Std.

Max.

Std.

Max.

15

30

15

50

—

50

—

60

Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . pages 3-10 through 3-12.

H362AWH
Interlocked Receptacle
Switch with Hubbell™
Hubbellock Receptacle

© 2012 Schneider Electric
All Rights Reserved

DE1

Discount
Schedule

3-9

Heavy Duty Safety Switches

Accessories
Class 3110 / Refer to Catalog 3100CT0901
www.schneider-electric.us

Rainproof Bolt-On Hubs—for use on NEMA 3R Enclosure
RB Hub

Conduit Size

3/4

1

1-1/4

1-1/2

2

2-1/2

3

3-1/2

4

Closing Cap

Hub Cat. No.

B075

B100

B125

B150

B200

B250

B300

B350

B400

BCAP

$ Price Each
33.30
33.30
33.30
33.30
61.00
102.00
186.00
300.00
368.00
3.80
(DE1A)
Note: NEMA 3R rainproof enclosures with Cat. No. ending in RB have a bolt-on closing cap factory-installed. Order bolt-on hubs separately
from table above. For more details see page 1-13. Hubs through size 2-1•2 can be directly installed on RB devices. Devices requiring threeinch or larger hubs must have holes cut in the field. Gaskets are provided on three-inch and larger hubs.
Note: All hubs are UL Listed for indoor and rainproof applications and suitable for use with conduit having ANSI standard taper pipe thread.

Watertight Hubs—for use on NEMA 4, 4X and 5 Stainless Steel and NEMA 12 Enclosures
Conduit Trade Size

1/2

3/4

1

1-1/4

1-1/2

2

2-1/2

3

3-1/2

4

Standard-Zinc
Hub Cat. No.

H050

H075

H100

H125

H150

H200

H250

H300

H350

H400

138.00

177.00

282.00

Zinc $ Price Each
Chrome Plated
Hub Cat. No.
Chrome Plated $ Price
Each

31.10

45.00

47.10

54.00

83.00

120.00

H050CP

H075CP

H100CP

H125CP

H150CP

H200CP

—

—

—

—

40.70

56.00

64.00

67.00

96.00

137.00

—

—

—

—

Electrical Interlock Kits

Table 3.24:

Electrical interlocks for heavy duty 30–1200 A safety switches are
available factory-installed or in kit form for field installation. Each kit
contains instructions for proper field mounting. A pivot arm operates
from switch mechanism, breaking the control circuit before the main
switch blades break. Switches with electrical interlocks installed are UL
Listed. For factory-installed electrical interlocks add EI (for one contact)
or EI2 (for two contacts) suffix to catalog number. See Supplemental
Digest page 2-3 for electrical interlock contact ratings.
Table 3.22:

Electrical Interlock Kit

a

3
SAFETY SWITCHES

Switch’s
Series Number
Electrical Interlock Kit $ Price Factory-Installed
Amperes Rating (See pages 3-13, 3-14)
Cat. No.b
$ Price
EIK031c d
F1, F5–F7
218.00
359.00
EIK032c d
30
EIK1
F3
311.00
452.00
EIK2
EIK1
F1-F3
311.00
452.00
F5–F7 (600 V)
EIK2
60
EIK031e
F4
218.00
359.00
F5–F6 (240 V)
EIK032e
EIK1
100–200
F2–F7
311.00
452.00
EIK2
EIK40601
400–1200
E1–E4
533.00
674.00
EIK40602
a
See page 3-7 for electrical interlocks on NEMA 4X fiberglass reinforced polyester and
Krydon™.
b
Electrical interlock kit catalog numbers with 1 suffix indicates one normally open and one
normally closed contact; 2 indicates two normally open and two normally closed contacts.
Kits are UL Listed.
c
HU461AWK uses EK3061 or EK3062.
d
The following Series F5–F7 devices use EIK-1, 2: H3612, H3612A, H3612AWK,
H3612RB, H461, H461DS, H461AWK, HU461, HU461DS, HU661DS, HU661AWK,
H361AWA, H361AWC, HU361AWA and HU361AWC.
e
H362WA, HU362WA, H362WC, H362AWA, HU362AWA, H362AWC, HU362AWC, and
H2212AWK use EIK1 or EIK2 electric interlock.
f
Single-pole single-throw interlock kits are rated 1/2 hp @ 110 and 220 Vac.

Class R Fuse Kits
When installed, this kit rejects all but Class R fuses. Kits are available for
field installation. For factory installation, add “CLR’’ suffix to catalog
number.
Table 3.23:

Class R Fuse Kits—240 V (one kit per 3P switch)

Series Number
Class R Fuse Kit
(See pages 3-13, 3-14)
Cat. No.
30
F5–F7
RFK03Lg
60
F1, F2, F3
RFK06
60
F4–F7
RFK03H
100
F2–F7
RFK10
200
F5–F6
HRK1020
400–600
E
HRK4060
g
H221-2AWK uses RFK06 Class R fuse kit.
Amperes

$ Price
25.50
25.50
25.50
47.70
47.70
111.00

Series Number
Class R Fuse Kit $ Price Factory-Installed
(See pages 3-13, 3-14)
Cat. No.
$ Price
30h
F1, F5–F7
RFK03Hi
25.50
293.00
30 h
F3
RFK06
25.50
293.00
60 h
F1–F7
RFK06H i
25.50
293.00
100 h
F2–F7
RFK10
47.70
231.00
200
F5–F6
HRK1020
47.70
231.00
400–600
E2–E4
HRK4060
111.00
360.00
h
See page 3-7 for Class R Fuse Kits in NEMA 4X Fiberglass Reinforced Polyester and
Krydon switches.
i
The following Series F5–F7 devices use RFK06: H3612, H3612A, H3612AWK, H3612RB,
H461, H461DS, H461AWK, H361AWA and H361AWC.

Internal Barrier Kits
Internal Barrier Kits provide an additional barrier that helps prevent
accidental contact with live parts. Field-installed transparent barriers do
not restrict visual inspection of the switch. Barriers provide IEC529 IP2X
“finger safe” protection when door of enclosed disconnect switch is
open. Convenient door allows use of test probes without accessing
fuses and replacement of fuses without removing barrier. Barrier can
also be used with the skirt kit to enclose a panel mounted Type 9422
disconnect.
Safety Switch Application
9422 Type T
(F Series Only)
Disconnect Application $ Price
240 / 600 Vac – 30 A
Interior Barrier for 30 A
SS03
NA
150.
Safety Switchj
240 Vac – 60 A
Interior Barrier for 60 A
600 Vac – 30 A
SS06
Safety Switch, 30 or
600 Vac – 60 A
165.
600 Vac – 60 A
60 A 9422 Switch
Interior Barrier for 100 A
SS10
Safety Switch or
240 / 600 Vac – 100 A
600 Vac – 100 A
195.
100 A 9422 Switch
Interior
Barrier
for
200
A
SS20
240 / 600 Vac – 200 A
NA
225.
Safety Switch
Skirt Kit to Enclose 30 or
600 Vac – 30 A
SS0306SK
60 A 9422 Switch
NA
225.
600 Vac – 60 A
(requires SS06)
Skirt Kit to Enclose 100 A
SS10SK
9422 Switch
NA
600 Vac – 100 A
255.
(requires SS10)
j
Requires arc shield on 240 V switches be changed to 600 V arc suppressor.
Cat. No.

Description

Fuse Puller Kits

Factory-Installed
$ Price
195.00
195.00
195.00
231.00
231.00
360.00

DE1

Class R Fuse Kits—600 V (one kit per 3P switch)

Amperes

Kit consists of three fuse pullers as required for a 3-pole fusible 240 V or
600 V heavy duty switch. Kits can be installed in switches manufactured
after February, 1980. Fuse pullers supplied as standard equipment on
NEMA 12, 12K, NEMA 4, 4X, 5 stainless steel, NEMA 4X fiberglass
reinforced polyester and KRYDON switches through 100 A.

k
l

3-10

381.00

DE1A

Amperes

Series Number

Fuse Puller Kit Cat. No.

$ Price

30
30

F1, F5–F7
F3

FPK03 k
FPK0610

30.00
42.60

60
60 l

F1, F2, F3, F5–F7 (600 V)
F4 l, F5–F7 (240 V)

FPK0610
FPK03 l

42.60
30.00

100

F2–F7

FPK0610

42.60

30 A 4- and 6-pole, H361-2 and H361-2RB Series F5 use FPK0610.
H362WA, H362WC, H362AWA, H362AWC, H362WH and H362AWH use FPK0610 fuse
puller kit.

Discount
Schedule

© 2012 Schneider Electric
All Rights Reserved

Heavy Duty Safety Switches

Accessories and Special Features
Class 3110 / Refer to Catalog 3100CT0901

www.schneider-electric.us

Neutral Assemblies—Field-Installed Neutral Assemblies for Fusible and Non-Fusible 240 and 600 Volt Safety Switches
Series Number
Amperes (See
pages 3-13, 3-14)
30

F1, F5–F6
F1–F3,
F5–F6 (600 V)
F4,
F5–F6 (240 V)

60

Standard
Neutral Kit
Cat. No.
SN03a
SN0610
SN03a

Terminal Data
AWG/kcmil

Copper Only
$ Price Optional
Neutral Kit Cat. No.

(3) 2 Max. Al/Cu
(2) 1/0 Max. Al/Cu
(2) 6 Max. Al/Cu
(3) 2 Max. Al/Cu

(3) 6 Max. Cu
(2) 1/0 Max. Cu
(2) 6 Max. Cu

102.00
114.00

83.00

SN03Ca

107.00

SN0610C

SN20A

200.00

SN20C

H600SN

(4) 750 Max. Al/Cu
(1) 300 Max. Al/Cu

327.00

H600SNC

753.00

—

—

—

1034.00

—

—

—

F2–F6

SN0610

200b

F5–F6

400 and
600

E1–E4

(6) 750 Max. Al/Cu
(2) 350 Max. Al/Cu
(8) 750 Max. Al/Cu
1200
E2–E4
H1200SNE4
(2) 350 Max. Al/Cu
Note: Neutrals cannot be installed in 4P, 6P, or 200 A NEMA 4X fiberglass reinforced polyester
safety switches.
a
The following Series F5–F6 devices use SN0610(C): H-361-2, H-361-2RB, H-361-2A and
H-361-2AWK.
b
For 200% neutral, order (2) neutral kits and (1) SN20NI neutral jumper kit.
(2) 350 Max. Al/Cu.
E2–E4

SN03C a
SN0610C

$ Price

(2) 1/0 Max. Al/Cu
(2) 6 Max. Al/Cu
(2) 250 Max. Al/Cu
(1) 1/0 Max. Al/Cu

100

800

83.00
107.00

Terminal Data
AWG/kcmil

H800SNE4

(3) 6 Max. Cu

102.00

(2) 1/0 Max. Cu
(2) 6 Max. Cu
(2) 250 Max. Cu
(1) 1/0 Max. Cu
(2) 600 Max. Cu
(2) 350 Max. Cu
(1) 250 Max. Cu

114.00
246.00
452.00

Equipment Grounding Kitsg
Equipment grounding kits are field-installed and UL Listed in 30–1200 A
heavy duty switches. For factory installation of equipment grounding kit, add
suffix GL to standard Cat. No. (Example: H361GL).
Price = Switch + Kit Price.
Equipment Grounding Kits—Field- or Factory-Installed Equipment Grounding Kits–240 and 600 V

30
60 d
60

Standard
Cat. No.
GTK03 c
GTK0610 d
GTK03

Terminal Data
AWG/kcmil
(2) 12 Cu or (2) 10 Al or (1) 4 Max. Al/Cu

Optional Copper Only
Cat. No.
11.40
GTK03C c

Terminal Data
AWG/kcmil
(1) 6 Max. Cu

(2) 1/0 Max. Al/Cu

18.90

GTK0610Cd

(2) 4 Max. Cu

22.70

(2) 12 Cu or (2) 10 Al or (1) 4 Max. Al/Cu

11.40

GTK03C

(1) 6 Max. Cu

13.40

$ Price

$ Price
13.40

GTK0610
(2) 1/0 Max. Al/Cu
18.90
GTK0610C
(2) 4 Max. Cu
22.70
PKOGTA2
(2) 2/0 Max. Al/Cu
55.00
PKOGTC2
(2) 4 Max. Cu
58.00
PKOGTA2e
PKOGTC3
400 and 600
E2–E4
(2) 2/0 Max. Al/Cu
55.00
(3) 1/0 Max. Cu
107.00f
(2 Required)
800
E2–E4
PKOGTA7
(4) 350 Max. Al/Cu
198.00f
—
—
—
1200
E2–E4
PKOGTA8
(8) 350 Max. Al/Cu
203.00f
—
—
—
c
The following Series F5–F6 devices use GTK0610(C): H-361-2 and H-361-2RB.
d
4- and 6-pole 30 A F Series.
e
Two required if grounding conductors are run in parallel.
f
PE1A Discount Schedule
g
Equipment Ground Kits are factory-installed standard in 30–200 A series F NEMA 4-4X-5 (stainless) and 12. Equipment Ground Kits are standard on all NEMA Types, Series F 30–200 A
4 and 6 pole switches.

Table 3.25:

Square D Gray Paint

Description
16 oz. Aerosol Paint Can, Square D Gray Paint
Note: Shipped in quantities of 6.

Price Adder Each Switch
Cat. No.
PK49SP

$ Price
39.00 ea.

Quantity

$ Price
30 A
242.00

10

60 A
278.00

100 A
434.00

200 A
479.00

400 A
1137.00

Special Paint

Lock-Off Guard Kitsd

UL Listed heavy duty switches are available painted with special safety
colors. To order safety colored switches add suffixes as noted in
Table 3.26 to the standard switch commercial reference number.
All colors comply with OSHA Standard 1910.144 and ANSI Specification
Z535.1 for marking physical hazards.

Available factory- or field-installed the
lock-off guard works by covering the
lockout/tagout opening whenever the switch
is in the ON position. This prevents a
padlock from being inadvertantly inserted
into the switch lockplate. The device is
designed to help prevent accidental
misapplication of a lockout device. These
kits are marked cURus (UL Component
Recognized) for field or factory installation.

Table 3.26:

Safety Colors

Safety Color
Suffix
Black
SP0
Red
SP2
Orange
SP3
Yellow
SP4
Green
SP5
Blue
SP6
Purple
SP7
Gray
SP8
Gray ANSI 61
SP861a
White
SP9
a
Standard Square D ANSI 49 grey paint, when selecting this suffix, switches will receive
additional coat of paint.

A minimum quantity of 10 is required. Not available for NEMA Type 7/9
or stainless steel products.

Amperesc
30 A
60 A 240 V
60 A 600 V
100 and 200 A
b
c
d

© 2012 Schneider Electric
All Rights Reserved

DE1

PE1A

600 A
2801.00

800 A
3501.00

1200 A
4376.00

3

100
200

Series Number
(See pages 3-13, 3-14)
F1, F5–F7
F1–F3d,
F5–F7 (600 V)
F4,
F5–F6 (240 V)
F2–F7
F5–F7

FactoryInstalled
$ Price

Kit Cat.
No.

Field-Installed
$ Price

LOGK1

44.30

146.00

LOGK2

45.00

177.00

For factory installation, add suffix “LOG” to the switch
catalog number.
For use with 30–200 Ampere Series F NEMA 1, 3R,
12 and 12K switches only.
Factory install and kits are available for NEMA 1, 3R,
12 and 12K switch enclosures only.

Discount
Schedule

SAFETY SWITCHES

Amperes

3-11

Heavy Duty Safety Switches

Accessories and Special Features
Class 3110 / Refer to Catalog 3100CT0901
www.schneider-electric.us

Key Interlock Systems
Factory-installed only on heavy duty safety
switches and double throw safety switches.
Interlocks are used to prevent the authorized
operator from making an unauthorized operation.
Not available on hazardous location devices
(NEMA 7/9) or fiberglass reinforced polyester
(NEMA 4X).
The key interlock system is a simple and easy
method of applying individual key interlock units
and assemblies to the above equipment so as to
require operation in a predetermined sequence.
UL Listed.

Copper Only Lug Kits
Heavy duty safety switches are supplied standard with Al lugs, which
accept both Cu and Al wires. For field installation of copper-only lug kits,
order kits below. For factory installation of copper only lugs, add suffix
SLC to standard Cat. No. Note: 30 through 200 Amperes NEMA 12, 12K
and stainless steel switches with factory-installed lugs bear the UL
Marine Listed manifest for use on vessels over 65 feet long. 30 through
200 Amperes NEMA 12, 12K and stainless steel switches using fieldinstalled copper only lug kits are UL Marine Listed, but do not bear the
marine manifest.
Table 3.30:

Quoting:
Contact Schneider Electric for catalog number, availability, and pricing prior
to quoting a job.
Detailed information is required before an order can be processed.
Please see Supplemental Digest Section 2 for further information.
Use these suffixes on switch catalog numbers:

•
•
•

Double Lug Kits

KI = 1 lock per switch
KI2 = 1 lock with 2 cylinders (2 keys) per switch
KIKI = 2 separate locks per switch

Table 3.27:

a

Price Adder Per Lock a

Switch Type
$ Price
30–1200 A Heavy Duty
2055.00
30–600 A Double Throw
1988.00
Prices do not apply when more than three devices are interlocked, as these schemes
normally require more than one key assembly per device.

Al/Cu to Cu Only

Lug Kitc
Cat. No.

Amperes

Lock-On Provisions
Lock-off provisions are standard on all heavy duty safety switches.
Provision for one 3•8-inch hasp padlock is available factory-installed on
NEMA 1, 3R, 4-4X-5 stainless steel and 12 switches. This modification
will allow the switch to be locked in the “ON’’ position. UL Listed.
Table 3.28:

Price Adder Per Each Switch

3

Safety Switch
Rating
To order, add suffix SPLO to standard
catalog number. Example: H364-SPLO

$ Price

30–1200 A

155.00

Cover Viewing Window
SAFETY SWITCHES

Optional cover viewing window is positioned over the
blades to allow visual verification of “ON-OFF’’ status.
Available on 30 through 1200 A heavy duty switches, all
NEMA Types. (Not available on NEMA 4X fiberglass
reinforced polyester, Krydon™ enclosures, or NEMA 7
and 9 devices.)
Factory-installed only: add “VW’’ suffix to the Cat. No.
See table below for price adder.
Table 3.29:
Class
Heavy Duty
Heavy Duty
Double Throw

Price Adder Per Switch—UL Listed
Amperes
30–100 A
400–1200 A
30–100 A

2- and 3-Pole
38.00
2297.00
255.00

4- and 6-Pole
75.00
—
510.00

Kit $ Priced

200 A heavy duty F-series switches
are supplied standard with lugs listed
on page 3-13 (one wire per phase).
For lugs that accept two wires per
phase and neutral, order the following
kit:

Lug wire range
per phase and neutral
AWG/kcmil
(2) 6 –300 Cu/Al

Field maintenance lubricant is available for servicing blade and jaw
components in switches 600 V and below. Catalog number SWLUB (list
price $24.14) consists of one tube of BG20 High Performance Synthetic
Grease manufactured by Dow Corning®. SWLUB is available in
warehouse stock, shipped individually or in multiples of 12 units per
carton.

Table 3.31:

800 and 1200 A Compression Lug Kits–
Field- Installed (See page 3-13 for 100–600 A Switches)
Series E4 800 and 1200 A safety switches are equipped as standard
with mechanical lugs. Alternate compression lug kits are available for
field installation and are UL Listed. Each kit consists of VCEL07512H1
Versa-Crimp™ Compression Lugs and lug landing connectors capable
of converting line and load side of one switch pole or neutral.
Order one field-installed kit per pole or neutral per table below.
Example: Three-pole three-wire requires three kits; three-pole, four-wire
requires four kits.
Lug Kit
Cat. No.
800
H8LKE2
1200
H12LKE2
Note: For terminal lug data, refer to table below.
Amperes

Amperes

System

2 Wire
800
3 Wire
4 Wire
2 Wire
1200
3 Wire
4 Wire
Note: For terminal Lug data refer to table below.

Amperes
800

1200

DE5

$ Price Per
Pole or Neutral
893.00
1109.00

Table 3.32:
Factory-Installed
Series E4 800 and 1200 A safety switches are available with factoryinstalled VCEL-075-12H1 Versa-Crimp compression lug kits (above).
For factory installation, add suffix LK to standard Cat. No. (Example:
H367LK) and use price adder from table below based on system type.

Table 3.33:

DE1

Switch wire range
per phase and neutral
AWG/kcmil
(2) 6 –250 Cu/Al

200
AL20DTF
159.00
c
Not UL Listed.
d
Kit contains 3 lugs. For double lugs for line and load, order 2 kits.

Switch Lubricant

3-12

Kits–Wire size (pp 3-13)

Lug Kit
Kit
Factory-Installed
Amperes Cat.
No.b $ Price
Adder per Switch
30
CL0306F
69.00
224.00
60
CL0306F
69.00
224.00
100
CL10F
159.00
431.00
200
CL20F
264.00
717.00
400
CL40F
549.00
1490.00
600
CL60F
893.00
2426.00
800
—
—
—
1200
—
—
—
bOne kit includes all phase line/load lugs for a 3pole switch.

Discount
Schedule

Factory-Installed
$ Price Adder Per Switch
2106.00
2972.00
3839.00
2591.00
3696.00
4806.00

Terminal Lug Data—800 and 1200 A Compression Lugs
Conductors
Per Phase
(3) Line
and
(3) Load
(4) Line
and
(4) Load

Compression Lug (VCEL-075-12H1)
Wire Range
500–750 kcmil (Al)
or
500 kcmil (Cu)
500–750 kcmil (Al)
or
500 kcmil (Cu)

© 2012 Schneider Electric
All Rights Reserved

Heavy Duty Safety Switches

NEMA Type 1 and 3R—Dimensions, Lug Data
Class 3110 / Refer to Catalog 3100CT0901

www.schneider-electric.us

Table 3.34:
Rating
(A)

W

30c
60d
100
200e

D

W/H

W/H

D

Typical NEMA 3R

Approximate Dimensions
Cat. No.
H221N
H221NRB
H222N
H222NRB
H223N
H223NRB
H224N
H224NRB
H225, N
H225NR, R
H226, N
H226NR, R
H227, N
H227NR, R
H228, N
H228NR, R
H265
H265R
H266
H266R
H267
H267R
H268
H268R
H321N
H321NRB
H322N
H322NRB
H323N
H323NRB
H324N
H324NRB
H325, N
H325R, NR
H326, N
H326R, NR
H327, N
H327R, NR
H328, N
H328R, NR
H361, N
H361-2
H361NRB, RB
H361WA
H361WC
H362, N
H362NRB, RB
H362WA
H362WC
H362WH
H363, N
H363NRB, RB
H363WA
H363WC

Series
F5
F5
F5
F5
F5
F5
F5
F5
E4
E5
E4
E5
E4
E4
E4
E4
E4
E5
E4
E5
E4
E4
E4
E4
F5
F5
F5
F5
F5
F5
F5
F5
E4
E5
E4
E5
E4
E4
E4
E4
F5
F5
F5
F6
F6
F5
F5
F6
F6
F5
F5
F5
F6
F6

© 2012 Schneider Electric
All Rights Reserved

H
in.
14.60
14.88
14.60
14.88
21.25
21.25
29.00
29.25
50.25
50.31
50.25
50.31
69.13
69.13
69.13
69.13
50.25
50.31
50.25
50.31
69.13
69.13
69.13
69.13
14.60
14.88
14.60
14.88
21.25
21.25
29.00
29.25
50.25
50.31
50.25
50.31
69.13
69.13
69.13
69.13
14.60
17.50
14.88
18.19
18.19
17.50
17.50
18.19
16.75
18.19
21.25
21.25
21.85
21.85

W
mm
371
378
371
378
540
540
737
743
1276
1278
1276
1278
1756
1756
1756
1756
1276
1278
1276
1278
1756
1756
1756
1756
371
378
371
378
540
540
737
743
1276
1278
1276
1278
1756
1756
1756
1756
371
445
378
462
462
445
445
462
425
462
540
540
462
555

in.
6.50
6.63
6.50
6.63
8.50
8.50
17.13
17.25
27.63
27.76
27.63
27.76
36.62
36.62
36.62
36.62
27.63
27.76
27.63
27.76
36.62
36.62
36.62
36.62
6.50
6.63
6.50
6.63
8.50
8.50
17.13
17.25
27.88
27.76
27.63
27.76
36.62
36.62
36.62
36.62
6.50
9.00
6.63
9.00
9.00
9.00
9.00
9.00
9.00
9.00
8.50
8.50
9.00
9.00

in.
4.88
4.88
4.88
4.88
6.38
6.38
8.25
8.50
10.13
9.53
10.13
9.53
17.75
17.75
17.75
17.75
10.13
9.53
10.13
9.53
17.75
17.75
17.75
17.75
4.88
4.88
4.88
4.88
6.38
6.38
8.25
8.50
10.13
9.53
10.13
9.53
17.75
17.75
17.75
17.75
4.88
6.38
4.88
6.81
6.81
6.38
6.38
6.81
7.00
6.81
6.38
6.38
6.81
6.81

12–2 (Al)
or
14–2 (Cu)
12–2 (Al) or 14–2 (Cu)
12–1/0 (Al) or 14–1/0 (Cu)
6–300 (Al/Cu)

—

—

Approximate Dimensions

D
mm
165
168
165
168
216
216
435
438
702
705
702
705
930
930
930
930
702
705
702
705
930
930
930
930
165
168
165
168
216
216
435
438
708
705
702
705
930
930
930
930
165
229
168
229
229
229
229
229
229
229
216
216
229
229

Optional Versa-Crimp™
Compression Lug
Field-Installedb

VCEL02114S1
VCEL030516H1
VCEL07512H1
1
1/0–750 (Al/Cu)f
1/0–750 (Al/Cu)
or
400
or
or
and
VCEL030516H1g
2
1/0–300 (Al/Cu)
1/0–300 (Al/Cu)
and
VCEL05012H1
600
2
3/0–500 (Al/Cu)
3/0–500 (Al/Cu)
VCEL05012H1
800
3
3/0–750 (Al/Cu)
3/0–750 (Al/Cu)
H8LKE2h
1200
4
3/0–750 (Al/Cu)
3/0–750 (Al/Cu)
H12LKE2 h
o
a
30–100 A switches suitable for 60°C or 75°C conductors. 200–1200 A switches suitable for 75 C conductors.
b
For NEMA 1 and 3R only.
c
HU461AWK— 14–3 AWG (Al or Cu).
d
H60XFA— 14–6 AWG (Cu).
e
H225XKA— 4 AWG–300 kcmil (Cu).
f
Max. wire range is (1) 600 kcmil or (2) 300 kcmil Al/Cu on NEMA 4X Stainless and NEMA 12.
g
Order two PK516KN mounting kits when installing VCEL030516H1 lugs.
Only one kit is required on 2-Pole switches.
h
See page 3-12, 800 and 1200 A compression lug kits for additional information.

H

Typical NEMA 1

1
1
1

Lug Wire Range
AWG/kcmil

W/H
mm
124
124
124
124
162
162
210
216
257
242
257
242
451
451
451
451
257
242
257
242
451
451
451
451
124
124
124
124
162
162
210
216
257
242
257
242
451
451
451
451
124
162
124
173
173
162
162
173
178
173
162
162
173
173

in.
7.55
7.55
7.55
7.55
10.50
10.50
18.50
18.63
27.63
27.88
27.63
27.88
36.62
36.62
36.62
36.62
27.63
27.88
27.63
27.88
36.62
36.62
36.62
36.62
7.55
7.55
7.55
7.55
10.50
10.50
18.50
18.63
27.88
27.88
27.63
27.88
36.62
36.62
36.62
36.62
7.55
10.50
7.55
10.50
10.50
10.50
10.50
10.50
10.50
10.50
10.50
10.50
10.50
10.50

Cat. No.
mm
192
192
192
192
267
267
470
473
702
708
702
708
930
930
930
930
702
708
702
708
930
930
930
930
192
192
192
192
267
267
470
473
708
708
702
708
930
930
930
930
192
267
192
267
267
267
267
267
267
267
267
267
267
267

H364, N
H364RB, NRB
H365, N
H365R, NR
H366, N
H366NR, R
H367, N
H367NR, R
H368, N
H368NR, R
H461
H462
H463
H464
H465
H466
HU265
HU265R
HU266
HU266R
HU267
HU267R
HU268
HU268R
HU361
HU361RB
HU361WA
HU361WC
HU362
HU362RB
HU362WA
HU362WC
HU362WH
HU363
HU363RB
HU363WA
HU363WC
HU364
HU364RB
HU365
HU365R
HU366
HU366R
HU367
HU367R
HU368
HU368R
HU461
HU462
HU463
HU464
HU465
HU466

Series
F5
F5
E4
E5
E4
E5
E4
E4
E4
E4
F5
F5
F5
F5
E4
E4
E4
E5
E4
E5
E4
E4
E4
E4
F5
F5
F6
F6
F5
F5
F6
F6
F5
F5
F5
F6
F6
F5
F5
E4
E5
E4
E5
E4
E4
E4
E4
F5
F5
F5
F5
E4
E4

H
in.
29.00
29.25
50.25
50.31
50.25
50.31
69.13
69.13
69.13
69.13
20.50
20.50
20.50
29.00
50.25
50.25
50.25
50.31
50.25
50.31
69.13
69.13
69.13
69.13
14.60
14.88
18.19
18.19
17.50
17.50
18.19
16.75
18.19
21.25
21.25
21.85
21.85
29.00
29.25
50.25
50.31
50.25
50.31
69.13
69.13
69.13
69.13
20.50
20.50
20.50
29.00
50.25
50.25

W
mm
737
743
1276
1278
1276
1278
1756
1756
1756
1756
521
521
521
737
1276
1276
1276
1278
1276
1278
1756
1756
1756
1756
371
378
462
462
445
445
462
425
462
540
540
462
555
737
743
1276
1278
1276
1278
1756
1756
1756
1756
521
521
521
737
1276
1276

in.
17.13
17.25
27.63
27.76
27.63
27.76
36.62
36.62
36.62
36.62
14.75
14.75
14.75
23.25
33.88
33.88
27.63
27.76
27.63
27.76
36.62
36.62
36.62
36.62
6.50
6.63
9.00
9.00
9.00
9.00
9.00
9.00
9.00
8.50
8.50
9.00
9.00
17.13
17.25
27.63
27.76
27.63
27.76
36.62
36.62
36.62
36.62
14.75
14.75
14.75
23.25
33.88
33.88

D
mm
435
438
702
705
702
705
930
930
930
930
375
375
375
591
861
861
702
705
702
705
930
930
930
930
165
168
229
229
229
229
229
229
229
216
216
229
229
435
438
702
705
702
705
930
930
930
930
375
375
375
591
861
861

in.
8.25
8.50
10.13
9.53
10.13
9.53
17.75
17.75
17.75
17.75
6.85
6.85
6.85
8.75
10.13
10.13
10.13
9.53
10.13
9.53
17.75
17.75
17.75
17.75
4.88
4.88
6.81
6.81
6.38
6.38
6.81
7.00
6.81
6.38
6.38
6.81
6.81
8.25
8.50
10.13
9.53
10.13
9.53
17.75
17.75
17.75
17.75
6.85
6.85
6.85
8.75
10.13
10.13

W/H
mm
210
216
257
242
257
242
451
451
451
451
174
174
174
222
257
257
257
242
257
242
451
451
451
451
124
124
173
173
162
162
173
178
173
162
162
173
173
210
216
257
242
257
242
451
451
451
451
174
174
174
222
257
257

in.
18.50
18.63
27.63
27.88
27.63
27.88
36.62
36.62
36.62
36.62
16.13
16.13
16.13
24.88
33.88
33.88
27.63
27.88
27.63
27.88
36.62
36.62
36.62
36.62
7.55
7.55
10.50
10.50
10.50
10.50
10.50
10.50
10.50
10.50
10.50
10.50
10.50
18.50
18.63
27.63
27.88
27.63
27.88
36.62
36.62
36.62
36.62
16.13
16.13
16.13
24.88
33.88
33.88

mm
470
473
702
708
702
708
930
930
930
930
410
410
410
632
861
861
702
708
702
708
930
930
930
930
192
192
267
267
267
267
267
267
267
267
267
267
267
470
473
702
708
702
708
930
930
930
930
410
410
410
632
861
861

3-13

SAFETY SWITCHES

H

2

Wire Range Wire Bending Space
Per NEC Table 312.6
AWG/kcmil
12–6 (Al) or 14–6 (Cu)
14–10 (Cu) solid or 14–10 (Cu)
stranded
14–3 (Al) or 14–3 (Cu)
12–1/0 (Al) or 14–1/0 (Cu)
6–250 (Al/Cu)

3

W

Terminal Lug Data (NEMA 1, 3R, 4, 4X, 5, 7, 9, 12)a

Conductors
Per Phase
and Neutral
1

Heavy Duty Safety Switches

NEMA Types 4, 4X, 5, 7, 9, 12 and 12K Dimensions
Class 3110 / Refer to Catalog 3100CT0901
www.schneider-electric.us

NEMA Type 4, 4X, 5, 7, 9 and 12
W

Approximate Dimensions
Cat. No.

W

D

H

H

H

W/H
D
Typical NEMA 4X
Typical NEMA 4, 4X, 5, 12,
Fiberglass Reinforced
12K (Stainless has flat front)
Polyester and Krydon™

Table 3.35:

W

D

Typical NEMA 7, 9

Optional Copper Only Lug Kits

(See page 3-12 for pricing. See page 3-13 for terminal lug data for the series switches listed in the
dimension table below.)
Amperes
Optional Lug Kit Cat. No.a
Lug Wire Range Per Phase AWG/kcmil
30–60
CL0306F
(1) 14–8 Cu solid or 14–4 Cu strand
100
CL10F
(1) 14–8 Cu solid or 14–1/0 Cu strand
200
CL20F
(1) 6–250 Cu
400
CL40F
(1) 1–600 Cu plus (1) 6–250 Cu
600
CL60F
(2) 4–350 Cu
a
One kit includes all phase line/load lugs for a 3-pole switch.

Table 3.36:

Conduit Provisions

(NEMA 4X Fiberglass Reinforced Polyester and Krydon, NEMA 7 and 9.)
Top and Bottom Endwall
Amperes

b
c

NEMA 4X Fiberglass
Reinforced Polyester and Krydonb
30
3/4 in.
60
1-1/4 in.
100
2 in.
200
2-1/2 in.
Hubs and hub drilling templates are provided for field-installation.
Threaded conduit opening.

NEMA 7 and 9c
—
3/4 in.
1-1/4 in.
2-1/2 in.

Approximate Dimensions
Cat. No.

3
SAFETY SWITCHES

H60XFA
H100XFA
H221AWK, A
H221DS
H221-2AWK
H222AWK, A
H222DS
H223AWK, A
H223DS
H224A,AWK
H224DS
H225AWK, DS
H225NAWK, NDS
H225XJG
H226AWK, DS
H226NAWK, NDS
H227AWK, NAWK
H228AWK, NAWK
H265AWK, DS
H266AWK, A, DS
H267AWK, NAWK
H268AWK, NAWK
H321AWK, A
H321DS
H322AWK, A
H322DS
H323AWK, A
H323DS
H324A,AWK
H324DS
H325AWK, DS
H325NAWK, NDS
H326AWK, DS
H326NAWK, NDS
H327AWK, NAWK
H328AWK, NAWK
H361AWA
H361AWC
H361AWK, A
H361DS
H361DSWA
H361DSWC
H361DF
H361DX
H361SS
H361-2AWK, A
H362AWA
H362AWC
H362AWH
H362AWK, A
H362DS

3-14

Series
E1
E1
F6
F6
F6
F6
F6
F6
F6
F6
F6
E4
E4
C2
E4
E4
E4
E4
E4
E4
E4
E4
F6
F6
F6
F6
F6
F6
F6
F6
E4
E4
E4
E4
E4
E4
F7
F7
F6
F6
F7
F7
F1
F1
F6
F6
F7
F7
F6
F6
F6

H
in.
15.93
15.93
14.60
14.93
16.50
14.60
14.93
20.50
20.82
29.00
29.00
46.25
46.25
22.56
46.25
46.25
69.13
69.13
46.25
46.25
69.13
69.13
14.60
14.93
14.60
14.93
20.50
20.82
29.00
29.00
46.25
46.25
46.25
46.25
69.13
69.13
16.50
16.50
14.60
14.93
16.87
16.87
16.50
19.40
14.93
16.50
16.50
16.50
16.50
16.50
16.87

W
mm
405
405
371
379
419
371
379
521
529
737
737
1175
1175
573
1175
1175
1756
1756
1175
1175
1756
1756
371
379
371
379
521
529
737
737
1175
1175
1175
1175
1756
1756
419
419
371
379
428
428
419
493
379
419
419
419
419
419
428

in.
9.87
9.87
6.63
7.22
9.00
6.63
7.22
9.00
9.36
17.25
17.75
26.25
26.25
10.88
26.25
26.25
36.62
36.62
26.25
26.25
36.62
36.62
6.63
7.22
6.63
7.22
9.00
9.36
17.25
17.75
26.25
26.25
26.25
26.25
36.62
36.62
9.00
9.00
6.63
7.22
8.92
8.92
11.00
11.40
7.22
9.00
9.00
9.00
9.00
9.00
8.92

D
mm
251
251
168
183
229
168
183
229
238
438
451
667
667
276
667
667
930
930
667
667
930
930
168
183
168
183
229
238
438
451
667
667
667
667
930
930
229
229
168
183
227
227
279
290
183
229
229
229
229
229
227

in.
6.96
6.96
4.96
5.11
7.00
4.96
5.11
7.00
6.97
8.75
8.88
10.13
10.13
7.75
10.13
10.13
17.75
17.75
10.13
10.13
17.75
17.75
4.96
5.11
4.96
5.11
7.00
6.97
8.75
8.88
10.13
10.13
10.13
10.13
17.75
17.75
7.00
7.00
4.96
5.11
5.11
5.11
8.80
8.60
5.11
7.00
7.00
7.00
7.00
7.00
6.97

W/H
mm
177
177
125
130
178
125
130
178
177
216
226
259
259
197
259
259
451
451
259
259
451
451
125
130
125
130
178
177
216
226
259
259
259
259
451
451
178
178
125
130
130
130
224
218
130
178
178
178
178
178
177

in.
9.87
9.87
7.55
8.67
10.50
7.55
8.67
10.50
11.25
18.63
19.25
26.25
26.25
10.88
26.25
26.25
36.62
36.62
26.25
26.25
36.62
36.62
7.55
8.67
7.55
8.67
10.50
11.25
18.63
19.25
26.25
26.25
26.25
26.25
36.62
36.62
10.50
10.50
7.55
8.67
10.81
10.79
11.00
11.40
8.67
10.50
10.50
10.50
10.50
10.50
10.81

mm
251
251
192
220
267
192
220
267
286
473
489
667
667
276
667
667
930
930
667
667
930
930
192
220
192
220
267
286
473
489
667
667
667
667
930
930
267
267
192
220
275
274
279
290
220
267
267
267
267
267
275

H362DSWA
H362DSWC
H362DF
H362DX
H362SS
H363AWA
H363AWC
H363AWK, A
H363DS
H363DSWA
H363DSWC
H363DF
H363DX
H363SS
H364A,AWK
H364DS,NDS
H364NA,NAWK
H364DF
H364SS
H365AWK, DS, SS
H365NAWK, NDS
H366AWK, DS
H366NAWK, NDS, SS
H367AWK, NAWK
H368AWK, NAWK
H461AWK
H461DS
H462AWK
H462DS
H463AWK
H463 DS
H464AWK
H464DS
H465AWK
H663AWK
H663DS
H664AWK
H664DS
HU265AWK, DS
HU266AWK, DS
HU267AWK
HU268AWK
HU361AWA
HU361AWC
HU361AWK, A
HU361DS
HU361DSWA
HU361DSWC
HU361DF
HU361DX
HU361SS
HU362AWA
HU362AWC
HU362AWH
HU362AWK, A
HU362DS
HU362DSWA
HU362DSWC
HU362DF
HU362DX
HU362SS
HU363AWA
HU363AWC
HU363AWK, A
HU363DS
HU363DSWA
HU363DSWC
HU363DF
HU363DX
HU363SS
HU364A,AWK
HU364DF
HU364DS
HU364SS
HU365AWK, DS, SS
HU366AWK, DS, SS
HU367AWK
HU368AWK
HU461AWK
HU461DS
HU462AWK
HU462DS
HU463AWK
HU463DS
HU464AWK
HU464DS
HU465AWK
HU661AWK
HU661DS
HU662AWK
HU662DS
HU663AWK
HU663DS
HU664AWK
HU664DS

Series
F7
F7
F1
F1
F6
F7
F7
F6
F6
F7
F7
F1
F1
F6
F6
F6
F6
E1
F6
E4
E4
E4
E4
E4
E4
F6
F6
F6
F6
F6
F6
F6
F6
E4
F6
F6
F6
F6
E4
E4
E4
E4
F7
F7
F6
F6
F7
F7
F1
F1
F6
F7
F7
F6
F6
F6
F7
F7
F1
F1
F6
F7
F7
F6
F6
F7
F7
F1
F1
F6
F6
E1
F6
F6
E4
E4
E4
E4
F6
F6
F6
F6
F6
F6
F6
F6
E4
F6
F6
F6
F6
F6
F6
F6
F6

H
in.
16.87
16.87
16.50
19.40
16.87
20.50
20.50
20.50
20.82
20.82
20.82
24.80
25.25
20.82
29.00
29.00
29.00
31.30
29.00
46.25
46.25
46.25
46.25
69.13
69.13
20.50
20.82
20.50
20.82
20.50
20.82
29.00
29.00
46.25
20.50
20.82
29.00
29.00
46.25
46.25
69.13
69.13
16.50
16.50
14.60
14.93
16.87
16.87
16.50
19.40
14.93
16.50
16.50
16.50
16.50
16.87
16.87
16.87
16.50
19.40
16.87
20.50
20.50
20.50
20.82
20.82
20.82
24.80
25.25
20.82
29.00
31.30
29.00
29.00
46.25
46.25
69.13
69.13
20.50
20.82
21.25
20.82
20.50
20.82
29.00
29.00
46.25
20.50
20.82
20.50
20.82
20.50
20.82
29.00
29.00

W
mm
428
428
419
493
428
521
521
521
529
529
529
630
641
529
737
737
737
795
737
1175
1175
1175
1175
1756
1756
521
529
521
529
521
529
737
737
1175
521
529
737
737
1175
1175
1756
1756
419
419
371
379
428
428
419
493
379
419
419
419
419
428
428
428
419
493
428
521
521
521
529
529
529
630
641
529
737
795
737
737
1175
1175
1756
1756
521
529
540
529
521
529
737
737
1175
521
529
521
529
521
529
737
737

in.
8.92
8.92
11.00
11.40
8.92
9.00
9.00
9.00
9.36
9.36
9.36
13.70
11.40
9.36
17.25
17.75
17.25
26.30
17.75
26.25
26.25
26.25
26.25
36.62
36.62
14.75
15.08
14.75
15.08
14.75
15.08
23.25
23.75
32.50
14.75
15.08
23.25
23.75
26.25
26.25
36.62
36.62
9.00
9.00
6.63
7.22
8.92
8.92
11.00
11.40
7.22
9.00
9.00
9.00
9.00
8.92
8.92
8.92
11.00
11.40
8.92
9.00
9.00
9.00
9.36
9.36
9.36
13.70
11.40
9.36
17.25
26.30
17.75
17.75
26.25
26.25
36.62
36.62
14.75
15.08
16.13
15.08
14.75
15.08
23.25
23.75
32.50
14.75
15.08
14.75
15.08
14.75
15.08
23.25
23.75

D
mm
227
227
279
290
227
229
229
229
238
238
238
348
290
238
438
451
438
668
451
667
667
667
667
930
930
375
383
375
383
375
383
591
603
826
375
383
591
603
667
667
930
930
229
229
168
183
227
227
279
290
183
229
229
229
229
227
227
227
279
290
227
229
229
229
238
238
238
348
290
238
438
668
451
451
667
667
930
930
375
383
410
383
375
383
591
603
826
375
383
375
383
375
383
591
603

in.
5.11
5.11
8.80
8.60
6.97
7.00
7.00
7.00
6.97
6.97
6.97
12.00
8.60
6.97
8.75
8.88
8.75
11.80
8.88
10.13
10.13
10.13
10.13
17.75
17.75
6.80
6.97
6.80
6.97
6.80
6.97
8.75
8.88
10.13
6.80
6.97
8.75
8.88
10.13
10.13
17.75
17.75
7.00
7.00
4.96
5.11
5.11
5.11
8.80
8.60
5.11
7.00
7.00
7.00
7.00
6.97
5.11
5.11
8.80
8.60
6.97
7.00
7.00
7.00
6.97
6.97
6.97
12.00
8.60
6.97
8.75
11.80
8.88
8.88
10.13
10.13
17.75
17.75
6.80
6.97
6.80
6.97
6.80
6.97
8.75
8.88
10.13
6.80
6.97
6.80
6.97
6.80
6.97
8.75
8.88

W/H
mm
130
130
224
218
177
178
178
178
177
177
177
305
218
177
216
226
216
300
226
259
259
259
259
451
451
173
177
173
177
173
177
222
226
259
173
177
222
226
259
259
451
451
178
178
125
130
130
130
224
218
130
178
178
178
178
177
130
130
224
218
177
178
178
178
177
177
177
305
218
177
216
300
226
226
259
259
451
451
173
177
173
177
173
177
222
226
259
173
177
173
177
173
177
222
226

in.
10.81
10.79
11.00
11.40
10.81
10.50
10.50
10.50
11.25
11.25
11.25
13.70
11.40
11.25
18.63
19.25
18.63
26.30
19.25
26.25
26.25
26.25
26.25
36.62
36.62
16.13
16.85
16.13
16.85
16.13
16.85
24.88
25.25
32.50
16.13
16.85
24.88
25.25
26.25
26.25
36.62
36.62
10.50
10.50
7.55
8.67
10.81
10.79
11.00
11.40
8.67
10.50
10.50
10.50
10.50
10.81
10.81
10.79
11.00
11.40
10.81
10.50
10.50
10.50
11.25
11.25
11.25
13.70
11.40
11.25
18.63
26.30
19.25
19.25
26.25
26.25
36.62
36.62
16.13
16.85
16.13
16.85
16.13
16.85
24.88
25.25
32.50
16.13
16.85
16.13
16.85
16.13
16.85
24.88
25.25

mm
275
274
279
290
275
267
267
267
286
286
286
348
290
286
473
489
473
668
489
667
667
667
667
930
930
410
428
410
428
410
428
632
641
826
410
428
632
641
667
667
930
930
267
267
192
220
275
274
279
290
220
267
267
267
267
275
275
274
279
290
275
267
267
267
286
286
286
348
290
286
473
668
489
489
667
667
930
930
411
428
410
428
410
428
632
641
826
410
428
410
428
410
428
632
641

© 2012 Schneider Electric
All Rights Reserved

Double Throw Safety Switches

Fusible and Non-Fusible
Class 3140 / Refer to Catalog 3100CT0901

www.schneider-electric.us

30–100 A Types DT, DTU (Series F)
•Fusible (DT) and non-fusible (DTU) switches available
•Manually-operated switch suitable for use in accordance with article 702 of the NEC, ANSI/NFPA 70
•Standards: UL 98, NEMA KS1, CSA, and NOM
•Modular design—switch handle, lock-plate, switch mechanism; line and load bases are field replaceable
•UL Listed short circuit current ratings up to 200 kA (using Class R, J, or T fuses—see table for rating)
•Load make/break rated
•Meets NEMA hp ratings
•Dual cover interlock
•May be padlocked ON (I) or OFF (O)
•Lock-off accepts up to three padlocks
•Side-opening door
•Quick make / quick break mechanism
•Meets NEMA requirements as heavy duty switch
•Field-installed electrical interlock kits
•Field-installed neutral assembly kits (2P and 3P switches)
•UL Listed as suitable for use as service equipment
•Supplied as standard for switching one load between two power sources, and may be field-converted to switch on power
source between two loads.

30 (Series T4), 200–600 A Types 82,000 and 200 A DTU (Series E, A)
•Non-fusible
•Designed for manual transfer of loads from one supply to another
•UL Listed switches are suitable for use in accordance with Article 702 of the National Electrical Code, ANSI / NFPA 70
•All 82,000 and DTU double throw switches are continuous duty rated for their nameplate ampere rating
•The 82,000 and DTU (Series E, A) switches are load make/break rated
•UL Listed as suitable for use as service equipment
•Horsepower rated only as footnoted.
Field-Installed Accessories:

SAFETY SWITCHES

—Neutral
—Electrical Interlock
—Grounding Terminals

3

30–100 A DT, DTU (Series F)
NEMA 1

82,000 Line
NEMA 1

© 2012 Schneider Electric
All Rights Reserved

3-15

Double Throw Safety
Switches

240 Volt
Class 3140 / Refer to Catalog 3100CT0901
www.schneider-electric.us

Table 3.37:

240 V Double Throw Safety Switches
Horsepower Ratings ab

System

Amperes Current
Series

NEMA 1

NEMA 4,4X,5
304 Stainless Steel

NEMA 3R

NEMA 12
Gasketed

240 Vac
Std.

Cat. No.

$ Price

Max.

Cat. No.

$ Price

Cat. No.

$ Price

Cat. No.

$ Price

1Ø

3Ø

1Ø

3Ø

250 Vdcc

Fusible—2P, 240 Vac—250 Vdc

Line

F

DT223

2379.00

DT223RB

3056.00

—

—

—

—

7.5

15 d

15

30 d

20

30
60

F
F

DT321
DT322

1646.00
1970.00

DT321RB
DT322RB

2216.00
2612.00

—
—

—
—

—
—

—
—

1.5 e
3e

3d
7.5 d

3e
10 e

7.5 d
15 d

5
10

100

F

DT323

3104.00

DT323RB

3725.00

—

—

—

—

7.5 e

15 d

15 e

30 d

20

—
DTU223RB

—
1347.00

—
—

—
—

—
—

—
—

—
—

—
—

10
15

—
—

10 f
20 f

100

Line

Load
Fusible—3P, 240 Vac—250 Vdc

Line

Line

Load
Non-Fusible—2P, 240 Vac—250 Vdc

Line

Line

60
100

F
F

DTU222
DTU223

962.00
1371.00

30
200
—
400

T4
E
—
A

92251 g
82254 k
—
82255 g

585.00
—
1815.00 DTU224NRB ghk
—
—
5850.00
82255R g

—
2177.00
—
8715.00

—
—
—
—

—
—
—
—

—
H82254
—
H82255 g

—
4671.00
—
10335.00

—
15
15
—

—
—
—
—

—
—
—
—

—
—
—
—

—
—
—
—

804.00
1119.00
1764.00

—
—
1953.00

—
—
—

—
—
—

—
—
—

—
—
—

—
—
—

3d
—
—

5e
10 e
15 e

10 d
15 d
30 d

5f
10 f
20 f

687.00
—
—
2564.00 DTU324NRB gh 3005.00
2798.00
—
—
8040.00
82355R g
13038.00
12555.00
DTU326R
13890.00

—
—
—
—
—

—
—
—
—
—

—
—
—
—
—

—
15
15
—
125

—
—
—
—
—

—
—
—
—
—

—
—
—
—
50

Load

3

Non-Fusible—3P, 240 Vac—250 Vdc

Line

SAFETY SWITCHES

30
60
100

F
F
F

DTU321
DTU322
DTU323

30
200
200
400
600
Non-Fusible—4P, 240 Vac
30
200
400

T4
E
E
A
A

92351 g
82354 g
DTU324N gh
82355 g
DTU326

T4
E
A

92451
82454 k
82455

953.00
5184.00
11505.00

—
82454R k
82455R

—
7517.00
16200.00

—
—
—

—
—
—

—
H82454 j
H82455

—
6779.00
15975.00

—
—
—

—
15 j
—

—
—
—

—
—
—

—
—
—

600

A

DTU426

20355.00

DTU426R

20595.00

—

—

—

—

—

125

—

—

50

Line

—
—
DTU323RB

Load

a
b
c
d
e
f
g
h
i
j
k

—
—
H82354 gi 5408.00
—
—
H82355 g 11715.00
—
—

Refer to page 7-31 for additional motor application data. The starting current of motors or more than standard horsepower may require the use of fuses with appropriate time delay
characteristics.
Std.—Using fast acting one time fuses. Max.—Using dual element time delay fuses.
For switching dc, use two switching poles.
If used on corner grounded delta systems, install neutral and use outer switching pole for ungrounded conductors.
Use outer switching poles.
Maximum rating.
240 Vac only.
Neutral included with device.
Suitable for use as service equipment.
Hp rating applies only to H82454.
250 V dc rated.

600 V Double Throw . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 3-17
Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 3-18
Application Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 3-19
Dimensions: 30–100 A (Series F) . . . . . . . . . . . . . . . . . . . . . . . . . page 3-20
Dimensions: 30, 200–600 A (Series E, T4, A) . . . . . . . . . . . . . . . . page 3-21

3-16

DE1

Discount
Schedule

© 2012 Schneider Electric
All Rights Reserved

Double Throw Safety Switches

600 Volt
Class 3140 / Refer to Catalog 3100CT0901

www.schneider-electric.us

Table 3.38:

600 V Double Throw Safety Switches
Horsepower Ratings ao
NEMA 1

Amperes Current
Series

System

NEMA 4,4X,5
304 Stainless Steel

NEMA 3R

NEMA 12
Gasketed

240 Vac
std

max

480 Vac
std

600 Vac

max

std

max

Cat. No.

$ Price

Cat. No.

$ Price

Cat. No.

$ Price

Cat. No.

$ Price

3Ø

3Ø 3Ø b 3Øb

3Ø

3Ø

DT361
DT362
DT363

2016.00
2111.00
3686.00

DT361RB
DT362RB
DT363RB

2678.00
3135.00
4427.00

—
—
—

—
—
—

—
—
—

—
—
—

—
—
—

—
—
—

7.5
15
30

20
50
75

Vdcb
250 600

Fusible 3P, 600 Vac—600 Vdc

Line

30
60
100

Line

F
F
F

5
15
25

15
30
60

5
—
—

15
30
50

10
30
40

30
5
60 g 10
75 h 20

15
30
50

—
—
50

—
—
—

Load
1Ø d 3Ø b 1Ø d 3Ø b 1Ø d 3Ø

Non-Fusible 3P, 600 Vac—600 Vdc

Line

Line

30
60
100

F
F
F

200
400
600

E
A
A

DTU361
DTU362
DTU363

879.00 DTU361RB
1254.00 DTU362RB
2036.00 DTU363RB

1544.00
—
2045.00 DTU362DS
3425.00 DTU363DS

—
—
—
6306.00 DTU362AWK p 3635.00
9414.00 DTU363AWK p 3894.00

5
10
20

10
20e
40h

7.5
20
25
50 g
40 75 hi

82344jn 2783.00 82344RB jn 5868.00 82344DSjr 11415.00 H82344ljq 7503.00
82345 n
8213.00 82345R n 13140.00 82345DS n 15675.00
H82345 n
12105.00
DTU366 ns 13890.00 DTU366R ns 19800.00
—
—
DTU366AWKns 21675.00

—
—
—

—
—
125

—
—
—

15 k
—
250

—
—
—

—
—
350

2Ø

3Ø

2Ø

3Ø

2Ø

3Ø

20
30

20
40

40
50

50
75

50
50

60
75

10
20

30
30

—
—
—

—
—
125

—
—
—

—
—
250

—
—
—

—
—
350

—
—
50

—
—
—

1Ø

3Ø

1Ø

3Ø

1Ø

3Ø

—
—

20
40

—
—

50
75

—
—

60
75

10
20

30
50

Load

Non-Fusible 4P, 600 Vac—600 Vdc

Line

Line

60
100

F
F

200
400
600

E
A
A

DTU462
DTU463

3035.00
Use NEMA 12
3851.00

—
—

DTU462DS
DTU463DS

6683.00 DTU462AWK p 4184.00
9978.00 DTU463AWK p 6123.00

82444 n
6143.00 82444R n 8130.00 82444DS n 15105.00
82445 n 12578.00 82445Rn 16800.00
—
—
DTU466 n 20355.00 DTU466R n 23475.00
—
—

H82444 ljn 7143.00
H82445n
16845.00
—
—

Non-Fusible 6P, 600 Vac—600 Vdc

Line

Line

60
100

F
F

—
—

—
—

—
—

—
—

—
—

DTU662AWK p 8474.00
DTU663AWK p 12735.00

—
—

SAFETY SWITCHES

Load

3

Load

a
b
c
d
e
f
g
h

Refer to page 7-31 for additional motor application data. The starting current of motors or more than
standard horsepower may require the use of fuses with appropriate time delay characteristics.
If used on corner grounded delta systems, install neutral and use outer switching pole for ungrounded
conductors.
For switching dc, use two switching poles.
Use outer switching poles.
Maximum Hp is 15 for corner grounded delta systems.
Maximum Hp is 30 for corner grounded delta systems.
Use 75oC #4 Cu or #2 Al conductors only.
Use 75oC #1 Cu conductors only.

i
j
k
l
m
n
o
p
q
r
s

Maximum Hp is 60 for corner grounded delta systems.
480 Vac maximum only, 250Vdc.
Standard Hp rating.
Not suitable for use as service equipment.
600 Vac max.
250 V dc rated.
Std.—Using fast acting one time fuses. Max.—Using dual element time delay
fuses.
(Non-fusible switches have max rating unless noted.)
Complete rating on switch is NEMA 3R or 12.
For 3R applications, remove drain screw from bottom endwall.
H82 ... and H92 ... devices are NEMA 12 only, intended for use indoors only.
Not UL Listed.
Copper lugs not listed or available.

240 V Double Throw . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 3-16
Accessories. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 3-18
Application Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 3-19
Dimensions: 30–100 A (Series F) . . . . . . . . . . . . . . . . . . . . . . . . . page 3-20
Dimensions: 30, 200–600 A (Series E, T4, A). . . . . . . . . . . . . . . . page 3-21

© 2012 Schneider Electric
All Rights Reserved

DE1

Discount
Schedule

3-17

Double Throw Safety Switches

Accessories
Class 3140 / Refer to Catalog 3100CT0901
www.schneider-electric.us

Table 3.38:

Neutral Assembly

Field-Installed
Terminal
Field-Installed
Terminal
Standard Neutral Kit
Data
$ Price
Copper only
Data
$ Price
Cat. No.
AWG/kcmil
Neutral Kit Cat. No. AWG/kcmil
30–100 A Type DT, DTU (Series F) (2- and 3-pole switches only)
SN0310
14–1/0 Al/Cu 114.00
SN0310C
14–1/0 Cu 120.00
30 A (Series T4) (2- and 3-pole switches only)
a
a
908.00
—
—
—
200 A Type 82000 and DTU (Series E) b
a
a
1110.00
—
—
—
(1) 4–600kcmil or 105.00
400 A Type 82000
DT400N
—
—
—
(2) 1/0–250kcmil
600 A Type DTU (Series A)
DT600NKD
250–500kcmil 452.00
—
—
—
a
For Type 82,000 switches, neutral is available factory-installed on 2P and 3P double throw switches. Not UL Listed. To order, add suffix N to the standard
catalog number and add the above price to the list price of the switch. For DTU switches, neutral is factory-installed in standard device and is UL Listed.
b
Neutral assembly catalog number DT200N can be added to 4P Type 82000 switches in the field.
Switch

Table 3.39:

Electrical Interlocks (For Electrical Interlock Contact Ratings, see Supplemental Digest page 2-4.)

Factory-Installed
Field-Installed Electrical Interlock Kit Cat. No. c
$ Price $ Price
Adder Per Switch
30–100 A Type DT, DTU (Series F)
EIK1, EIK2 dh
311.00
905.00e
200 A Type 82000 and DTU (Series E) f
g
—
1113.00e
400 A Type 82000
EK400DTU2
260.00
1533.00
600 A Type DTU (Series A)
DS200EK2D
438.00
—
c
Electrical interlock kit catalog numbers with “1” suffix indicate one normally open and normally closed contact; “2” indicates two normally open and two
normally closed contacts. See page 3-10 for electrical interlock ratings.
d
30–100 A Type DT, DTU (Series F) switches contain (2) separate switching mechanisms. Each mechanism will accept an electrical interlock. Some
applications may therefore require (2) electrical interlocks.
e
30–100 A Type DT, DTU (Series F) switches with factory-installed electrical interlocks installed are UL Listed and interlocks are furnished with 2 N.O. /2
N.C. contacts installed in both “ON” positions. To order, add suffix EI to standard catalog number.
f
Electrical interlock EK400DTU2 can be added to 4-pole Type 82000 switches in the field.
g
Type 82000 and DTU switches are available with electrical interlock factory-installed only. Not UL listed. Electrical interlocks are furnished with 2
N.O./N.C. contacts and are installed in both “ON” positions. To order, add suffix EI to standard switch catalog number.
h
Double throw switches 92251, 92351, and 92451 are not available with factory or field installed electrical interlocks.
Switch

Table 3.40:

Service Grounding Kit (Required for service equipment use.)

Switch
30–100 A Type DT, DTU (Series F)
30 A Type 92,000
200 A Type 82000 and DTU (Series E)

Field-Installed Service Grounding Lug Kit Cat. No.
Included
DT30SG
DT100SG
PKOGTA2
(2 required)
DS468GKD

400 A Type 82000
600 A Type 82000 (Series A)

Table 3.41:

Terminal Data AWG/kcmil
Included
(4) 14–4 Cu/Al
(3) 14–1/0 Cu/Al
(4) 10–2/0 Cu or
(4) 6–2/0 Al
6–250kcmil

$ Price
std.
29.40
30.00
55.00
309.00

Class R Fuse Kits

When installed, this kit rejects all but Class R fuses. Kits are available for field installation. For factory installation, add “CLR” suffix to catalog number.
Switch

Series Number

Class R Fuse Kit Cat. No.

3

Class R Fuse Kits—240 V (two kits per 3P switch)
30 A
F5
60 A
F5
100 A
F5
Class R Fuse Kits—600 V (two kits per 3P switch)
30 A
F5
60 A
F5
100 A
F5

$ Price

Factory-Installed

$ Price

RFK03
RFK06
RFK10

24.50
25.50
47.70

390.00
390.00
390.00

RFK06
RFK06H
RFK10

25.50
25.50
47.70

390.00
390.00
390.00

SAFETY SWITCHES

Viewing Windows
See Table 3.29 for list price. Accessory available on 30–100 A DTU switches only.
Key Interlock Systems
For factory-installed key interlocks, refer to page 3-12.
Phenolic Legend Plate
For factory-installed phenolic legend plates, refer to Supplemental Digest page 2.3.
Lock-On Provisions—UL Listed
Standard and feature on 30–100 A type DT and DTU (Series F), 82,000 (400 A only) and type 92,000 switches.
Feature available as facatory installed option for Type 82,000 (200 A only) and 200 A DTU (Series E) switches. Add the
suffix SPLO to the catalog number and add $410. to the switches list price.
Table 3.42:

“RB Hub”

Rainproof Bolt-On Hubs—for use on NEMA 3R Enclosures

Conduit Size

3/4

1

1-1/4

1-1/2

2

2-1/2

3

3-1/2

4

Closing
Cap

Hub Cat. No.

B075

B100

B125

B150

B200

B250

B300

B350

B400

BCAP

$ Price Eachi
33.30
33.30
33.30
33.30
61.00
102.00
186.00
300.00
368.00
3.80
Note: NEMA 3R rainproof enclosures with catalog number ending in RB have a bolt-on closing cap factory-installed. Order bolt-on hubs separately
from table above. For more details see page 1-13. Hubs through size 2-1/2 in. can be directly installed on RB devices. Devices requiring 3
in. or larger hubs must have holes cut in the field. Gaskets are provided on 3 in. and larger hubs.
Note: All hubs are UL Listed for indoor and rainproof applications and suitable for use with conduit having ANSI standard taper pipe thread.
i
See Discount Schedule.

Table 3.43:

Watertight Hubs—for use on NEMA 4, 4X and 5 Stainless Steel and NEMA 12 Enclosures

Conduit Trade Size

1/2

3/4

1

1-1/4

1-1/2

2

2-1/2

3

3-1/2

4

Standard-Zinc Hub Cat. No.

H050

H075

H100

H125

H150

H200

H250

H300

H350

H400

120.00

138.00

177.00

282.00

381.00

Zinc $ Price Each
Chrome Plated Hub Cat. No.
Chrome Plated $ Price Each

31.10
H050CP

45.00
H075CP

40.70

47.10
H100CP

56.00

64.00

54.00
H125CP
67.00

83.00
H150CP
96.00

H200CP
137.00

—

—

—

—

—

—

—

—

240 V Double Throw . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 3-16
600 V Double Throw . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 3-17
Application Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 3-19
Dimensions: 30–100 A (Series F) . . . . . . . . . . . . . . . . . . . . . . . . . . page 3-20
Dimensions: 30, 200–600 A (Series E, T4, A) . . . . . . . . . . . . . . . . page 3-21

3-18

DE1

DE1A

Discount
Schedule

© 2012 Schneider Electric
All Rights Reserved

Double Throw Safety Switches

Application Data
Class 3140 / Refer to Catalog 3100CT0901

www.schneider-electric.us

30–100 A Type DT
(Series F):
Select DT switches from
pages 3-16, 3-17, which
have provisions for
accepting fuses.
30 A, 200–600 A Type
82,000 (Series E, T4, A),
all DTU devices:
Use the non-fusible
double throw switches
from pages 3-16, 3-17 in
conjunction with standard
fusible devices, and
install them according to
diagram 1 or 2, below.
Line
Non-Fusible
Double Throw
Switch
Line

Table 3.44:

UL Listed Short Circuit Current Ratings

Switch Type
Type DT
(Series F)
DTU b

Type
(Series F)
DTU224NRB and
DTU324NRB
(Series E)
DTU324N
(Series E)

Voltage
Rating

UL Listed
Fuse Class

30–100 A

240 V or
600 V

30–100 A

240 V or
600 V

H, K
R, J
H or K
R, J or T

Short Circuit
Current Rating a
(A)
10,000
200,000
10,000 c
200,000

200 A

240 V

H, K

10,000 c

H, K
10,000 c
R, J
100,000
H, K
10,000 c
240 V
Type 82,000
all
R, J
100,000 d
600 V
H, K
10,000 c
H, K
10,000
Type DTU (A series)
600 A
240 V or 600 V
R, J, T
100,000
a
Rating applies to AC only. The UL Listed short circuit current rating for non-fusible switches is based on the switch being used in conjunction with the
corresponding fuse type. Evaluation of non-fusible switches in conjunction with molded case circuit breakers has not been performed.
b
The DTU361 and DTU361RB are also suitable for use on a circuit capable of delivering not more than
(A) 18 kA, 600 Vac maximum when protected by Type FH circuit breaker rated 30 A maximum or
(B) 14 kA, 600 Vac maximum when protected by Type FA circuit breaker rated 30 A maximum.
c
Any brand of circuit breaker or fuse not exceeding the ampere rating of the switch may be used ahead of a non-fusible safety switch when there is up to
10 kA short circuit current available.
d
400 A 82,000 switch is only 10 kA.

Table 3.45:

200 A

240 V

Terminal Lug Data for Type DT, DTU (Series F) Double Throw Safety Switches
NEMA 1, 3R, 4, 4X, 12

Wires
per
Phase

Wire Range Wire Bending Space
Per NEC Table 373-6
AWG/kcmil
30–60 A
12–2 Al
Type DT, DTU
1
or
(Series F)
14–2 Cu
100 A
12–1/0 Al
Type DT, DTU
1
or
(Series F)
14–1/0 Cu
e
Thomas and Betts catalog numbers.
f
Hubbell Versa-Crimp™ catalog numbers.
Switch Type

Fusible Single
Throw Switch
or Circuit
Breaker

Amperes

Table 3.46:
Load

Standard Lug
Wire Range
AWG/kcmil
12–2 Al
or
14–2 Cu
12–1/0 Al
or
14–1/0 Cu

Amperes

Wires per
Phase

Wire Range Wire Bending Space
Per NEC Table 373-6
AWG/kcmil

30 A (Series T4) h

1

14–8 Al/Cu

Line
200

Non-Fusible
Double
Throw
Switch

Load

1
1
or
2
600
2
o
200–600 A switches suitable for 75 C conductors.
30 A switches suitable for 60oC or 75oC conductors.
Hubbell Versa-Crimp™ catalog numbers.
400

g
h
i

VCEL02114S1 f

Optional Copper Only Lug

See pages 3-12 and 3-14 for appropriate
kit.
Order two kits per switch.

Terminal Lug Data for Types 82,000 and for A and E-Series DTU devices

Diagram 1

Fusible
Single Throw
Switch or
Circuit
Breaker

Optional
Compression Lug
Field-Installed
C10-14,
D8-14,
or E6-14 e

6–300 Al/Cu
1/0–600 Al/Cu
or
1/0–300 Al/Cu
250–500 Al/Cu

Lug Wire Range
AWG/kcmil

g
Optional Compression Lugs
Field-Installed

12–2 Al
or
14–2 Cu
6–300 Al/Cu

VCEL030516H1 i

1/0–600 Al/Cu

—

250–500 Al/Cu

—

—

SAFETY SWITCHES

Situations Requiring
Fuses

240 V Double Throw . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .page 3-16
600 V Double Throw . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 3-17
Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .page 3-18
Dimensions: 30–100 A (Series F) . . . . . . . . . . . . . . . . . . . . . . . . . .page 3-20
Dimensions: 30, 200–600 A (Series E, T4, A). . . . . . . . . . . . . . . . .page 3-21

3

Fusible
Single Throw
Switch or
Circuit
Breaker
Line

Diagram 2

© 2012 Schneider Electric
All Rights Reserved

DE1

Discount
Schedule

3-19

Double Throw Safety Switches

Dimensions—Series F Devices
Class 3140 / Refer to Catalog 3100CT0901
www.schneider-electric.us

Table 3.47:

W

H

D

W/H

NEMA 1
W

H

3
W/H

D

30–100 A Type DT, DTU (Series F)—Approximate Dimensions

Cat. No.

Series

DT223
DT223RB
DT321
DT321RB
DT322
DT322RB
DT323
DT323RB
DT361
DT361RB
DT362
DT362RB
DT363
DT363RB
DTU222
DTU223
DTU223RB
DTU321
DTU322
DTU323
DTU323RB
DTU361
DTU361RB
DTU362
DTU362AWK
DTU362DS
DTU362RB
DTU363
DTU363AWK
DTU363DS
DTU363RB
DTU462
DTU462AWK
DTU462DS
DTU463
DTU463AWK
DTU463DS
DTU662AWK
DTU663AWK

F5
F5
F5
F5
F5
F5
F5
F5
F5
F5
F5
F5
F5
F5
F5
F5
F5
F5
F5
F5
F5
F5
F5
F5
F6
F6
F5
F5
F6
F6
F5
F5
F6
F6
F5
F6
F6
F6
F6

H
in.
38.00
38.00
38.00
38.00
38.00
38.00
38.00
38.00
38.00
38.00
38.00
38.00
38.00
38.00
29.94
29.94
30.50
29.94
29.94
29.94
30.50
29.94
30.50
29.94
29.94
30.26
30.50
29.94
29.94
30.26
30.50
29.94
30.26
30.26
29.94
30.26
30.26
30.26
30.26

W
mm
965
965
965
965
965
965
965
965
965
965
965
965
965
965
760
760
775
760
760
760
775
760
775
760
760
769
775
760
760
769
775
760
769
769
760
769
769
769
769

in.
9.88
6.87
10.25
10.25
10.25
10.25
9.88
6.87
10.25
10.25
10.25
10.25
9.88
6.87
10.25
10.25
10.25
10.25
10.25
10.25
10.25
10.25
10.25
10.25
10.25
10.25
10.25
10.25
10.25
10.25
10.25
10.25
15.50
15.50
10.25
15.50
15.50
15.50
15.50

W/H
mm
251
174
260
260
260
260
251
174
260
260
260
260
251
174
260
260
260
260
260
260
260
260
260
260
260
260
260
260
260
260
260
260
394
394
260
394
394
394
394

in.
11.13
8.12
11.50
11.80
11.50
11.80
11.13
8.12
11.50
11.80
11.50
11.80
11.13
8.12
11.96
11.96
11.96
11.96
11.96
11.96
11.96
11.96
11.96
11.96
11.96
11.50
11.96
11.96
11.96
11.50
11.96
11.96
16.75
16.75
11.96
16.75
16.75
16.75
16.75

D
mm
283
206
292
300
292
300
283
206
292
300
292
300
283
206
304
304
304
304
304
304
304
304
304
304
304
292
304
304
304
292
304
304
425
425
304
425
425
425
425

in.
6.75
6.60
6.75
6.60
6.75
6.60
6.75
6.60
6.75
6.60
6.75
6.60
6.75
6.60
6.93
6.93
6.93
6.93
6.93
6.93
6.93
6.93
6.93
6.93
6.93
7.12
6.93
6.93
6.93
7.12
6.93
6.93
7.12
7.12
6.93
7.12
7.12
7.12
7.12

mm
171
168
171
168
171
168
171
168
171
168
171
168
171
168
176
176
176
176
176
176
176
176
176
176
176
181
176
176
176
181
176
176
181
181
176
181
181
181
181

240 V Double Throw . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 3-16
600 V Double Throw . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 3-17
Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 3-18
Application Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 3-19
Dimensions: 30, 200–600 A (Series E, T4, A) . . . . . . . . . . . . . . . . page 3-21

NEMA 3R
SAFETY SWITCHES

W

H

W/H

D

NEMA 4, 4X, 5 and 12

3-20

© 2012 Schneider Electric
All Rights Reserved

Double Throw Safety Switches

Dimensions—Series A, E, and T4 Devices
Class 3140 / Refer to Catalog 3100CT0901

www.schneider-electric.us

30, 200–600 A Types 82,000 and E-Series DTU devices, NEMA 1 and
3R—Approximate Dimensions

Cat. No.

W/H
W

D

H

NEMA 1

W/H
W

D

H

DTU—200 A
NEMA 3R

DTU224NRB a
82254 a
82254NW a
82344 a
82344RB a
82354
92251
82344DS
DTU324N
DTU324NRB
H82344
H82444 a
H82454
82454
82444
82454R a
82444R
H82254
H82354
82444DS a
82255 a
82255R
82345a
82345DSa
82345Ra
82355 a
82355R a
82445
82445R
82455 a
82455R
H82255
H82345
H82355
H82445
H82455
DTU326
DTU426
DTU366
DTU466
DTU326R
DTU426R
DTU366R
DTU466R
DTU366AWK
a
250 V dc rated.

Series
E1
E1
E1
E2
E1
E1
T4
E1
E1
E1
E2
E2
E3
E3
E3
E3
E3
E3
E3
E3
A1
A1
A1
A1
A1
A1
A1
A1
A1
A1
A1
A1
A1
A1
A1
A1
A1
A1
A1
A1
A1
A1
A1
A1
A1

H
in.
32.50
30.88
30.88
30.88
32.50
30.88
10.00
30.88
32.50
32.50
32.50
32.50
32.50
38.00
38.00
38.00
38.00
32.50
32.50
38.00
38.50
39.00
38.50
39.00
39.00
38.50
39.00
38.50
39.00
38.50
39.00
39.00
39.00
39.00
39.00
39.00
63.31
63.31
63.31
63.31
63.76
63.76
63.76
63.76
63.76

W
mm
826
784
784
784
826
784
254
784
826
826
826
826
826
965
965
965
965
826
826
965
978
991
978
991
991
978
991
978
991
978
991
991
991
991
991
991
1608
1608
1608
1608
1619
1619
1619
1619
1619

in.
20.63
15.75
20.00
20.00
20.63
20.00
8.00
20.00
24.50
24.50
24.50
30.21
30.21
29.62
29.62
29.62
29.62
24.50
24.50
29.62
26.10
26.62
26.10
26.62
26.62
26.10
26.62
30.10
30.21
30.10
30.21
26.62
26.62
26.62
30.21
30.21
23.66
27.00
23.66
27.00
23.66
27.00
23.66
27.00
23.66

W/H
mm
524
400
508
508
524
508
203
508
622
622
622
767
767
753
753
753
753
622
622
753
663
676
663
676
676
663
676
765
767
765
767
676
676
676
767
767
601
686
601
686
601
686
601
686
601

in.
24.00
19.63
23.88
23.88
24.00
23.88
9.75
23.88
26.25
26.25
26.25
33.61
33.61
33.02
33.02
33.02
33.02
26.25
26.25
33.02
29.51
30.02
29.51
30.02
30.02
29.51
30.02
33.50
33.61
33.50
33.61
30.02
30.02
30.02
33.61
33.61
24.46
27.80
24.46
27.80
24.46
27.80
24.46
27.80
24.46

D
mm
610
499
607
607
610
607
248
607
667
667
667
854
854
839
839
839
839
667
667
839
750
763
750
763
763
750
763
851
854
851
854
763
763
763
854
854
621
706
621
706
621
706
621
706
621

in.
10.63
9.75
11.75
11.75
10.63
11.75
4.75
11.75
10.63
10.63
10.63
10.63
10.63
10.63
10.63
10.63
10.63
10.63
10.63
10.63
10.63
10.63
10.63
10.63
10.63
10.63
10.63
10.63
10.63
10.63
10.63
10.63
10.63
10.63
10.63
10.63
8.88
8.88
8.88
8.88
8.88
8.88
8.88
8.88
8.88

mm
270
248
298
298
270
298
121
298
270
270
270
270
270
270
270
270
270
270
270
270
270
270
270
270
270
270
270
270
270
270
270
270
270
270
270
270
226
226
226
226
226
226
226
226
226

3

240 V Double Throw . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 3-16
600 V Double Throw . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 3-17
Accessories. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 3-18
Application Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 3-20
Dimensions: 30–100 A (Series F) . . . . . . . . . . . . . . . . . . . . . . . . . . page 3-20

SAFETY SWITCHES

Table 3.48:

© 2012 Schneider Electric
All Rights Reserved

3-21

Dimensions

1000 Vdc Photovoltaic Heavy Duty
Disconnect Switch

Class 3110
www.schneider-electric.us

Put over 100 years of Schneider Electric’s experience as
a global specialist in energy management to work on your
photovoltaic (PV) project. The Square D™ 1000 Vdc
disconnect switch is the perfect solution for your 1000 Vdc

PV disconnect applications. It is compact and available in
both a 100 and 200 amp non-fusible versions. IEC 609471 and 3 certified (file 136861) and UL 98 certified (file
E343341).

Extended Life Expectancy

Designed for Harsh PV Environments

Exceeds IEC 60947-3 mechanical endurance
requirements by factor of 18
Exceeds IEC 60947-1 electrical endurance requirements
by factor of 10
Exceeds NEMA KS-1 mechanical endurance
requirements by factor of 3.

NEMA Type 3 and IP63 enclosure

•
•

Resists windblown dirt/dust
Exceeds NEMA Type 1, 3R and 12

Operating range of -37°C to 50°C
Specially designed PV paint reduces solar gain up to 35%
over standard grey enclosures

Easy to Install
Preconfigured solar solution
Familiar enclosed safety switch design
Suitable for both grounded and ungrounded PV
Table 3.49:

1000 Vdc Photovoltaic Heavy Duty Disconnect Switch Pricing and Accessories
Factory Installed Accessories
NEMA 1, 3R, 12, 3
and IP63

System

Amperes

Cat. No.

Electrical Interlock Electrical Interlock
Single Contacta
Two Contactsb

Viewing
Windows

Terminal Blocks
(Copper)c

3 Wire
Ground
Lugd

Price No. Suffix $ Price No. $ Price No. $ Price No. $ Price
$ Price No. Suffix $Adder
Adder Suffix Adder Suffix Adder Suffix Adder

Height Width
(in.)
(in.)

Depth
(in.)

3 Pole Groundede
Three-Pole (Grounded System)

Connector

Line

Connector

100

REHU393IP 1672.00

EI

452.00

EI2

496.00

VW

150.00

TBC

409.00

GL

263.00

22.13

18.63

8.75

200

REHU394IP 2246.00

EI

452.00

EI2

496.00

VW

175.00

TBC

409.00

GL

263.00

22.13

18.63

8.75

100

REHU493IP 2507.00

EI

452.00

EI2

496.00

VW

150.00

—

—

GL

263.00

29.00

18.63

8.75

200

REHU494IP 3965.00

EI

452.00

EI2

496.00

VW

175.00

—

—

GL

263.00

29.00

18.63

8.75

Load

PE
Protective earth terminal

3

4 Pole Ungrounded
Four-Pole (Ungrounded System)

SAFETY SWITCHES

Load

Line

Load

Line

Connector

PE
Protective earth terminal

a
b
c

Order EIK1PV for single contact field-installed kit $311.00.
Order EIK2PV for double contact field-installed kit $355.00.
Accommodates (2) 250 max Cu or (1) 1/0 max Cu wiring; Order

d
e

SN20CPV for field-installed kit $246.00.
Order REHGND KIT for field installable kit $100.00.
Terminal blocks standard with 3 pole switches; accommodates (2) 1/0
max Al/Cu or (2) 6 max Al/Cu wiring.

Schneider Electric gives the Photovoltaic market place the most comprehensive one stop shop
for Residential and Light Commercial Photovoltaic Balance of System components. Schneider
Electric's Inverters, and Square D brand DC and AC disconnect switches and Load Centers are
ideal solutions to your Balance of Systems requirements. See the Balance of System solution
chart below for your single phase PV system.
Table 3.50:

200 A Enclosed Switch Dimensions (inches)

PV Balance of System Solution Package—Grid Tie

System Voltage

Kilowatts

Amps

DC Disconnect

Inverter

250 Vdc

2.8

30

HU361RB

878-2801

D221NRB

250 Vdc

3.3

60

HU362RB

878-3301

D222NRB

QO140M225

250 Vdc

3.3

100

HU363RB

878-3301

D223NRB

QONQ42MS400

600 Vdc

3.8

30

HU361RB

878-3801

D221NRB

QO130M200

600 Vdc

5.0

60

HU362RB

878-5001

D222NRB

QO140M225

600 Vdc

5.0

100

HU363RB

878-5001

D223NRB

QONQ42MS400

For internal 600 Vdc PV combiner box switches please see our offering of 9422
switches 600 Vdc UL98 listed in digest pages 8-14.

3-22

DE1

Discount
Schedule

AC Disconnect Load Center Product
QO130M200

For our 600 Vdc PV switch offering please see digest pages 3-5–3-6.

© 2012 Schneider Electric
All Rights Reserved

String Combiner Boxes

Dimensions
Class 3140 / Refer to Catalog 3100CT0901

www.schneider-electric.us

Square D PV string combiner boxes are used to integrate multiple PV strings into one output
circuit. Its tough exterior and safety features protect wiring from weather and overcurrent. The
exterior coating ensures low operating temperatures and longer life of internal components.
The specially engineered enclosure is designed to provide dust tight and rain tight protection;
it meets or exceeds NEMA® 3R, 12, and 4 requirements. Traditional Square D visible blade
switch architecture confirms disconnection, while touch-safe interior shielding protects
against accidental contact with live components.

Features
Flexible

•
•
•

Vertical, horizontal, and angled mounting options
Flexible installation with top, bottom, and side entry
Substantial wire-bending space

Robust

•
•
•

Dust tight and rain tight engineered enclosure for outdoor use
UV-resistant white exterior coating to reduce solar gain by 35%
Meets or exceeds NEMA 3R, 12, and 4 requirements

Safe

•
•
•
•

Square D traditional visible blade switch architecture for confirmation of disconnect
Touch-safe interior shielding guards against accidental contact with current-carrying components
Seismic-certified 100–400 amp string combiner boxes for earthquake safety
Optional integrated 2.5 kV surge arrestor to protect PV electronics from lightning strikes

Listings
• UL 1741
• Switches tested to UL98B
• CSA C22.2 Spec 107.1
600 Vdc Photovoltaic Combiner Boxes

Maximum
Wire Range (AWG/kcmil—Copper Only)
Continuous Maximum Continuous
Output
DC Output PV Module
Input
List
Input Output Circuit Number
of
Ground
Current
Isc Rating
Current
Price $
Circuit
(+
and
-)
Conductors
In
(Max.)
(Amps)
Per String
(+ and -)
(+ or -)
(Amps)
REHSC126100
12
100
838.00 #12–#6
#6–1/0
1
REHSC166200
16
200
1067.00 #12–#6 #6–300 MCM
1
#14–4 Or
10.4
13
2X #14–#12
REHSC246300
24
300
1378.00 #12–#6
1/0–300
2
REHSC326400
32
400
2226.00 #12–#6
1/0–300
2
a
For factory installed surge protection device add the suffix “S” to the catalog number.
Catalog
Numbera

Table 3.52:

Number
Input
Circuits
(Max.)

Width

Depth

Ground
Out

in.

mm

in.

mm

in.

mm

#6–2/0
#6–2/0
#6–2/0
#6–2/0

20.78
27.78
35.78
35.78

528
706
909
909

14.50
20.25
20.25
20.25

368
514
514
514

6.13
6.13
6.13
6.13

156
156
156
156

600 Vdc Photovoltaic Combiner Boxes With Disconnects

Maximum
Wire Range (AWG/kcmil—Copper Only)
Continuous Maximum Continuous
Output
DC Output PV Module
Input
List
Input Output Circuit Number
of
Ground
Current
Isc Rating
Current
Price $
Circuit
(+
and
-)
Conductors
In
(Max.)
(Amps)
Per String
(+ and -)
(+ or -)
(Amps)
REHSC126100DU
12
100
1438.00 #12–#6
#6–1/0
1
REHSC166200DU
16
200
1899.00 #12–#6 #6–300 MCM
1
#14–4 Or
10.4
13
2X #14–#12
REHSC246300DU
24
300
3035.00 #12–#6
1/0–300
2
REHSC326400DU
32
400
3883.00 #12–#6
1/0–300
2
a
For factory installed surge protection device add the suffix “S” to the catalog number.
Catalog
Numbera

Outside Dimmensions
Height

Number
Input
Circuits
(Max.)

Outside Dimmensions
Height

Width

Depth

Ground
Out

in.

mm

in.

mm

in.

mm

#6–2/0
#6–2/0
#6–2/0
#6–2/0

31.00
31.00
41.00
41.00

787
787
1041
1041

19.00
25.00
25.00
25.00

483
635
635
635

9.00
9.00
10.50
10.50

229
229
267
267

SAFETY SWITCHES

Table 3.51:

The 600 Vdc Type 2 Surge Protection Device (SPD) is for medium risk PV applications. The
SPD when installed in a Square D combiner box protects solar modules, power tracking and
blocking diodes from physical damage resulting from lightning induced transients. The SPD
device uses Metal Oxide Varistor (MOV)/Gas-Filled Spark Gap (GSP) protection circuits for
longer life and no current leakage. The devices are UL1449 ed 2 compliant Low Voltage
TVSS. The SP are available as factory installed by adding the suffix “S” to the combiner box
catalog number or as kits a kit: REHTYPE2SP.
Table 3.53:

Typical String Combination Box Dimensions

© 2012 Schneider Electric
All Rights Reserved

600 Vdc Type 2 Surge Protection Device

Catalog
Number

Network
Voltage

Nominal
Discharge
Current
per 20
micro sec

Maximum
Discharge
Current
per 20
micro sec

Operating
Current

Operating
Temperature;
Celsius

List Price $

REHTYPE2SP

600 Vdc

20kA

40kA

<0.1nA

-40 to +85

Kit
337.00

Factory
Installed
490.00

3-23

3

Surge Protection Device

www.schneider-electric.us

3
SAFETY SWITCHES

3-24

© 2012 Schneider Electric
All Rights Reserved



Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.6
Linearized                      : Yes
Create Date                     : 2014:10:23 10:57:57-04:00
Modify Date                     : 2014:10:23 10:57:57-04:00
XMP Toolkit                     : Adobe XMP Core 5.4-c005 78.147326, 2012/08/23-13:03:03
Metadata Date                   : 2014:10:23 10:57:57-04:00
Format                          : application/pdf
Document ID                     : uuid:6e740c0c-54f4-4f63-aaa5-ce4cdb31ad43
Instance ID                     : uuid:1307862d-0c67-4e71-8456-289bfdd0c594
Page Mode                       : UseNone
Page Count                      : 24
EXIF Metadata provided by EXIF.tools

Navigation menu