646385 Catalog
2014-09-04
: Pdf 646385-Catalog 646385-Catalog 622454 Batch7 unilog
Open the PDF directly: View PDF .
Page Count: 49
Download | |
Open PDF In Browser | View PDF |
Pocket Pro w w w. i p ex e l e c t r i c a l . c o m E L E C T R I C A L S Y S T E M S ® TM TM Trenchless Raceways Systems ® ® ® ® ® ® UL Underwriters Laboratories Inc. (UL 50 and UL 508) 1 Indoor use primarily to provide protection against contact with the enclosed equipment and against a limited amount of falling dirt. 2 Indoor use to provide a degree of protection against limited amounts of falling water and dirt. 3 Outdoor use to provide a degree of protection against windblown rain; undamaged by the formation of ice on the enclosure. 4 Either indoor or outdoor use to provide a degree of protection against falling rain, splashing water, and hose-directed water; undamaged by the formation of ice on the enclosure. 4X Either indoor or outdoor use to provide a degree of protection against falling rain, splashing water, and hose-directed water; undamaged by the formation of ice on the enclosure; resists corrosion. 6P Indoor or outdoor use primarily to provide a degree of protection against hose-directed water, the entry of water during prolonged submersion at a limited depth, and be undamaged by the formation of ice on the enclosure. 12 Indoor use to provide a degree of protection against dust, dirt, fiber flyings, dripping water, and external condensation of noncorrosive liquids. 13 Indoor use to provide a degree of protection and spraying of water, oil, and noncorrosive liquids. 1 Type Designation 2 3 4 5 6 This material is reproduced with permission from Underwriters Laboratories Inc. Standard for Safety for Cabinets and Boxes, UL 50, Copyright 1988 and Industrial Control Equipment, UL 508, Copyright 1994 by Underwriters Laboratories Inc. 7 Underwriters Laboratories Inc. (UL) shall not be responsible to anyone for the use of or reliance upon a UL Standard by anyone. UL shall not incur any obligation or liability for damages, including consequential damages, arising out of or in connection with the use, interpretation of, or reliance upon a UL Standard. 8 TABLE OF CONTENTS Applications . . . . . . . . . . . . . . . . . . . . . . . . . .3 Advantages . . . . . . . . . . . . . . . . . . . . . . . . . .4 SCEPTER PVC CONDUIT Introduction . . . . . . . . . . . . . . . . . . . . . . . . . .2 1 Scepter® Rigid PVC Conduit . . . . . . . . . . . . . . .7 Expansion and Contraction . . . . . . . . . . . . . . . . . . .10 Conduit Dimensions . . . . . . . . . . . . . . . . . . . . . . . .15 Fittings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .18 Cover Plates . . . . . . . . . . . . . . . . . . . . . . . . . . . . .33 Weatherproof Covers . . . . . . . . . . . . . . . . . . . . . . . .34 CONDUIT REPAIR KIT Scepter® PVC Conduit Fittings . . . . . . . . . . . .17 SCEPTER PVC FITTINGS Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8 Boxes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .41 Conduit Repair Kit . . . . . . . . . . . . . . . . . . . .43 EPR Kits . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .43 SCEPTALIGHT Conduit Cements & Primers . . . . . . . . . . . . . . . . . .42 EPR Kit Adapters . . . . . . . . . . . . . . . . . . . . . . . . . .43 Cor-Line® ENT & Kwikon® Fittings . . . . . . . . . .53 CORLINE ENT & KIWKON FITTINGS SceptalightTM: Nonmetallic Light Fixtures . . . .45 Cor-Line Tubing . . . . . . . . . . . . . . . . . . . . . . . . . . .56 Kwikon Fittings . . . . . . . . . . . . . . . . . . . . . . . . . . .57 Kwikon Accessories . . . . . . . . . . . . . . . . . . . . . . . .61 SUPERDUCT Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .56 Super Duct® . . . . . . . . . . . . . . . . . . . . . . . . . .63 Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .65 Pipe . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .70 SCEPTACON Advantages/Engineering Data . . . . . . . . . . . . . . . . .64 Fittings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .71 Vertical-Lok Spacers . . . . . . . . . . . . . . . . . . . . . . . .76 SceptaConTM Trenchless Raceway Systems . . .79 Kwikpath® Communication Raceway Systems . .81 KWIKPATH Monobloc® Spacers . . . . . . . . . . . . . . . . . . . . . . . .77 2 APPLICATIONS INTRODUCTION Engineers, electricians, contractors, specifiers and utilities have realized for many years the advantages of PVC. Today, IPEX electrical systems include Scepter® PVC conduit and fittings, Super Duct® power and communication ducts, Cor-Line® ENT, Kwikon® ENT fittings and FiberTel® high density polyethylene innerduct. These brands are the number-one choice for power, communication and data needs. Whether exposed, concealed in walls, encased in concrete, or directly buried, IPEX electrical products are preferred For The Long Run. Only when you specify IPEX branded products by name are you guaranteed our commitment to excellence. Applications Typical industrial/commercial and residential applications for IPEX electrical systems include: • Utilities • Cable • Communications • Street and highway lighting • Residential applications Pocket Pro provides the most comprehensive information about PVC systems – from basic raw material to installation characteristics of the finished product. Written with the engineer, contractor and distributor in mind, it is based on laboratory test results and IPEX’s many years of field experience. At IPEX, we have been extruding PVC conduit and molding fittings since 1951. We formulate our own compounds, maintain strict quality control during production, and offer one of the most comprehensive lines of nonmetallic electrical products throughout North America. More important, our commitment to customers extends beyond the sale. Quality control and thorough jobsite field reports have earned IPEX a reputation for product quality and service excellence. • Water treatment plants • Airports • Subways • Sewage treatment plants • Pulp and paper industries • Parking garages • Car washes • Fish plants • Marinas • Agricultural, dairy, hogs, cattle, chicken, etc. • Bridges and tunnels • Food processing plants • Steel mills • Mines 3 4 ADVANTAGES ADVANTAGES Labour Savings Easy Wire Pulls Compared to metal, PVC products reduce labour on a typical installation by up to two-thirds. The reason? PVC is easy to work with. It can also be cut and joined without pipe vises, cutters, threading equipment and reamers associated with metal conduit. PVC’s exceptionally smooth interior surface greatly reduces the amount of friction while pulling conductors/wires through long runs, even with 90° bends. A large pull-rope and wire-pulling compound should be used when pulling all conductors and wires. Lightweight Conduit Noncorroding Scepter Rigid PVC Conduit is one-half the weight of aluminum and one-sixth the weight of steel. As a result, handling and installation are easier and faster, reducing labour costs. PVC is immune to damage from naturally corrosive soil conditions, as well as electrochemical and galvanic corrosion. This ensures lower maintenance costs and superior performance For The Long Run. Sunlight Resistant The 2006 Canadian Electrical Code rule 2-130 is intended to ensure that totally enclosed nonmetallic raceways are properly protected against adverse effects from direct exposure to UV rays. Electrical nonmetallic raceways marked for such applications are suitable for installation and use in direct exposure to the rays of the sun. Scepter rigid PVC Conduit meets the criteria for sunlight resistance, is approved for the purpose, and is appropriately marked. Easy Joining Solvent cementing is all that is required, eliminating the need for power-threading machines, pipe vises and cutting equipment. A hacksaw or carpenter’s saw is the only equipment required. Strength Scepter Rigid PVC Conduit offers both high impact and high tensile strength, even in cold temperatures. Scepter Rigid PVC Conduit and fittings meet and exceed all CSA and UL standards. Scepter Rigid PVC Conduit CSA Impact Test UL Impact Test Size (in) 1/2 Size (mm) 12 8.9 ft.lbs. (12 joules) 50 ft.lbs. 3/4 20 8.9 ft.lbs. (12 joules) 80 ft.lbs. (109 joules) @ -29°F (-34°C) @ 72°F (23°C) (68 joules) 1 25 8.9 ft.lbs. (12 joules) 100 ft.lbs. (136 joules) 1 1/4 32 8.9 ft.lbs. (12 joules) 120 ft.lbs. (163 joules) 1 1/2 40 8.9 ft.lbs. (12 joules) 150 ft.lbs. (204 joules) 2 50 8.9 ft.lbs. (12 joules) 190 ft.lbs. (258 joules) 2 1/2 65 8.9 ft.lbs. (12 joules) 210 ft.lbs. (285 joules) 3 – 6 75 – 150 8.9 ft.lbs. (12 joules) 220 ft.lbs. (298 joules) Nonconducting Scepter Rigid PVC conduit pipe and fittings are nonsparking and nonconducting, thereby eliminating the most dangerous ‘second point of contact’ and ‘phase to ground’ faults. The use of a separate grounding conductor provides a complete and positive ground for the whole system. Chemical Resistance One of the greatest benefits of PVC is its excellent chemical resistance. It resists attack by acids, alkalies, salt solutions, and many other types of chemicals. For more information on PVC and chemical resistance, refer to the IPEX Chemical Resistance Guide. Long Life Scepter Rigid PVC Conduit pipe and fittings retain their original properties after years of exposure to heat and weather. In addition, resistance to fungi, bacterial action, rodents, termites and corrosive agents ensures a long, trouble-free life for PVC conduit installed indoors or outdoors. Concrete Tight Scepter Rigid PVC Conduit pipe and fittings are designed and engineered to be concrete tight in all weather conditions. 5 6 SCEPTER RIGID PVC CONDUIT ADVANTAGES SCEPTER PVC CONDUIT Fire Resistant IPEX’s proprietary PVC compound used to manufacture Scepter products is a self-extinguishing material and will not support combustion. Samples taken from an actual fire show the outer surface of the conduit was blistered and charred. The interior of the conduit, however, was unaffected. Additionally, the undamaged conductors were then removed and reinstalled in new conduit. Fire-resistant characteristics when tested to CAN ULC S102.2 are as follows: 0.080" (2mm) thickness Flame Spread 10 – 20 Smoke Developed 225 – 270 Fuel Contribution 0 0.630" (16mm) thickness 10 – 20 300 – 390 0 IPEX Compound FT-4 Rating Scepter Rigid PVC conduit is certified to meet the requirements of FT-4 allowing its use in noncombustible construction per Section 3.1.5.20 of the National Building Code, which reads: 1.) Subject to the limits on the size of elements that penetrate fire separations as stated in Sentence 3.1.9.3.(2), within a fire compartment of a building required to be of noncombustible construction, totally enclosed nonmetallic raceways not more than 175mm in outside diameter, or of an equivalent rectangular area, are permitted to be used to enclose optical fibre cables and electrical wires and cables, provided the raceways exhibit a vertical char not more than 1.5m when tested in conformance with the Vertical Flame Test (FT - 4) Conduit or Tubing on Cable Tray in Clause 6.16 of CSA C22.2 No. 211.0, “General Requirements and Methods of Testing for Nonmetallic conduit.” Suitable for Direct Burial PVC is suitable for direct burial and requires no extra protection when installed in accordance with the Canadian Electrical Code and the local inspection authority guidelines. The usual care regarding trenches and backfilling should be respected. One-Source Specification IPEX offers a full range of PVC fittings and accessories. As a result, it is easy to specify a single source PVC system. Quality Control In addition to IPEX’s quality control testing, all Scepter electrical products carry third-party certification by CSA, UL and NRTL. 7 This section covers the most comprehensive design and installation of Scepter Rigid PVC Conduit pipe and fittings. Always consult the authority having jurisdiction for specific installation procedures. CSA C22.2 No. 211.2 CSA C22.2 No. 211.0 FT-4 for 1/2" to 6" NEMA TC-2 Corps. of Engineers Spec. CE 303:01 Military Spec, Federal Spec. WC 1094A INSTALLATION INSTALLATION Support Solvent Cementing Due to PVC’s light weight, support spacing is different than that used with metal conduits. Supporting straps should NOT be firmly tightened, so that linear movement of the pipe is possible. The maximum allowable support spacing, as per Canadian Electrical Code (CEC), is as follows: After cutting Scepter Rigid PVC conduit, sharp edges or burrs from inside the conduit should be removed with a knife. Thoroughly clean the end of the pipe and inside the fitting with a pipe cleaner. Apply a generous amount of IPEX solvent cement to both surfaces; slide together and give a quarter turn to ensure the solvent is spread evenly on the material. Hold together for a few seconds until the joint is made. Support Spacing For Scepter Rigid PVC Conduit Pipe Nominal Conduit Diameter inches mm 1/2 12 3/4 20 1 25 1-1/4 32 1-1/2 40 2 50 2-1/2 65 3 75 3-1/2 90 4 100 5 125 6 150 Maximum Support Spacing feet metres 2-1/2 0.75 2-1/2 0.75 2-1/2 0.75 4 1.2 4 1.2 5 1.5 6 1.8 6 1.8 7 2.1 7 2.1 7 2.1 8 2.5 Maximum Operating Temperature The Canadian Electrical Code (CEC) allows the use of Scepter Rigid PVC Conduit up to a maximum ambient temperature of 167°F (75°C). Cutting Scepter Rigid PVC conduit can be easily cut on the jobsite by using a hacksaw, carpenter’s saw or PVC conduit cutters. For larger sizes of conduit, the use of a mitre box is also recommended to ensure a square cut. Usually the solvent-cemented joint will be strong enough to install immediately. However, in climates with low temperatures or areas with high humidity, extra time may be required before moving the pipe for permanent installation. Solventcemented joints appear to “set up” instantly, but will take 24 hours to cure properly. After this time, the solvent-cemented joint has completely cured and is waterproof. For extreme cold weather installations, the use of IPEX PVC Primer is recommended. IPEX cements and primers are available in quarter-pint (125ml), half-pint (250ml), pint (500ml), quart (1-litre) and gallon (4-litre) containers. Bending PVC is a thermoplastic material that, when heated, becomes soft and pliable. As a result, its shape can be altered. A flameless heat source is recommended to heat the pipe. AN OPEN FLAME SHOULD NOT BE USED. Either an electric unit or an infra-red propane unit is recommended. The necessary temperature for bending pipe is 260°F (127°C). The pipe must be heated evenly over an area approximately ten times the diameter of the pipe before any attempt at bending is made. Bending the pipe when it has not been thoroughly heated will cause the pipe to “kink.” With proper care and a little practice, the bend will form easily. Cooling the pipe with cold air or water will cause “spring back.” Allow a few extra degrees of overbending to compensate. Maximum bending radius shall be six times the internal diameter according to the Canadian Electrical Code. 9 SCEPTER PVC CONDUIT SCEPTER PVC CONDUIT 8 11 EXPANSION & CONTRACTION EXPANSION & CONTRACTION Using Expansion Joints Number of Expansion Joints Required It’s just as important to know when to use an expansion joint as it is to know how to install it correctly. Expansion joints are required when the temperature change is greater than 25°F (14°C). Scepter Rigid PVC conduit has a coefficient of linear expansion of 3.6 x 10-4 in./ft./°F (.054mm/m/°C.) Generally, a 100 ft. (30.48m) run of PVC conduit will undergo a change in length of 3.6 inches (91.44mm) for every 100°F (56°C) temperature change. Use the following equation to determine the number of expansion joints needed for a Scepter Rigid PVC Conduit installation: Number of joints = total expansion (mm or in) E E = Expansion joint travel length 101.6mm (4") or 203.2mm (8") depending on diameter. Always round up to the next whole number. For conduit installed indoors, the range of expansion and contraction can be calculated using the maximum air temperature plus the heat contributed by the conductors inside the conduit and minimum air temperature expected. Expansion joints are not required indoors unless there are widely varying temperatures such as the attic of a building. Setting the Piston Opening The expansion joint must be installed to allow for expansion and contraction of the conduit run. On a cold day, if an expansion joint is installed completely closed with the piston bottomed, there is no room for expansion when the conduit is warmed. If it is installed open to the maximum on a hot day, the expansion joint will pull apart when cooled. Conduit installed outdoors, exposed to direct sunlight, will be considerably hotter than the air temperature. As a guideline in this case, add 27°F (15°C) to the temperature change. Expansion joints should be installed to allow for all anticipated temperature changes. The correct piston opening for any installation condition can be easily determined using the formula below: Piston setting = PVC PIPE LENGTH VARIATION DUE TO TEMPERATURE CHANGE (ºF) Coefficient = 3.6 x 10-4 in/ft/ºF Expansion Formula °F Total Expansion (in.) = length of run (ft.) x temperature change (°F) x 0.00036 TEMPERATURE CHANGE IN ºF By using the following formulas and the charts below, the total expected expansion in a run can be easily determined: Compressed length + 120 100 80 ) xE PVC PIPE 70 60 As a general rule for every temperature change of 10ºF, PVC pipe will expand or contract 3/8" per 100' 50 40 30 20 10 0 1 2 3 4 LENGTH VARIATION in/100 ft OF PIPE 5 PVC PIPE LENGTH VARIATION DUE TO TEMPERATURE CHANGE (ºC) Coefficient = .054/mm/m/ºC TEMPERATURE CHANGE IN ºC max. temp. – min. temp. Formula can be used for both metric and imperial measurements. 90 60 Total Expansion (mm) = length of run (m) x temperature change (°C) x 0.054 max. temp. – installation temp. 110 or °C ( 55 50 45 40 PVC PIPE 35 30 25 20 15 10 5 0 As a general rule for every temperature change of 5ºC, PVC pipe will expand or contract 2.7mm per 10m .5 1.0 1.5 2.0 2.5 3.0 3.5 LENGTH VARIATION mm/m OF PIPE Size (mm) (in) 13 20 25 32 38 51 64 76 89 102 127 152 1/2 3/4 1 1-1/4 1-1/2 2 2-1/2 3 3-1/2 4 5 6 Compressed Length (mm) (in) (mm) (in) 203.2 203.2 215.9 228.6 228.6 235.0 235.0 362.0 362.0 362.0 362.0 362.0 101.6 101.6 101.6 101.6 101.6 101.6 101.6 203.2 203.2 203.2 203.2 203.2 4 4 4 4 4 4 4 8 8 8 8 8 8.00 8.00 8.50 9.00 9.00 9.25 9.25 14.25 14.25 14.25 14.25 14.25 Travel SCEPTER PVC CONDUIT SCEPTER PVC CONDUIT 10 EXPANSION & CONTRACTION EXPANSION & CONTRACTION Location of Expansion Joints Figure 1 Proper functioning of an expansion joint depends on three procedures: 1. The correct placement of the expansion joint. 2. The proper installation of Scepter Rigid PVC conduit and the expansion joint. 3. The proper placement and fastening of support straps. One Expansion Joint Figure 1 If only one expansion joint is needed between two boxes, the barrel of the joint is rigidly fastened close to the first box. Scepter Rigid PVC conduit should then be loosely supported with straps, allowing the conduit to move freely as it expands and contracts. Figure 2 Two Expansion Joints Figure 2 If two expansion joints are needed, the joints should be firmly fastened back to back at the centre of the run. Scepter Rigid PVC conduit is loosely supported with straps, allowing the conduit to move freely as it expands and contracts. Figure 3 Two Expansion Joints (Alternative) Figure 3 Alternatively, the centre of the run and the two expansion joints (located at the boxes) should be rigidly fastened. All other support straps should be loosely fastened. Three or More Expansion Joints Figure 4 If more than two joints are needed in a very long run, they should be put in a series, one after the other. Each barrel must be rigidly fastened while conduit is loosely supported with straps allowing the conduit to move freely as it expands and contracts. When installed in a series, each section acts independently of the other. Spacing of conduit supports must be in accordance with Section 12-1114 of the Canadian Electrical Code (CEC). Figure 4 13 SCEPTER PVC CONDUIT SCEPTER PVC CONDUIT 12 15 CONDUIT DIMENSIONS EXPANSION & CONTRACTION Installation of Expansion Joints Scepter Rigid PVC Conduit Dimensions (inches) Installation recommendations: • Expansion joints should be mounted so the piston can travel in a straight line in the barrel. If the alignment is not straight, the piston will bind, preventing the joint from functioning correctly. Nominal Product Code Size • The expansion joint barrel should be clamped tight, but the conduit mounted loose enough in its hangers to allow for movement as it expands and contracts. • Scepter nonmetallic straps are correctly sized and designed for proper support, and must be used to secure the conduit. • When expansion joints are used in a vertical position, the piston should be mounted in a downward position so dirt cannot deposit between the barrel and piston at the muzzle of the expansion joints. 1/2 3/4 1 1-1/4 1-1/2 2 WARNING 2-1/2 3 Common Mistakes Three common mistakes are: 1. Forgetting to use expansion joints. 3-1/2 4 2. Not using enough expansion joints. 3. Overtightening of support straps. It is more cost effective to use more expansion joints than needed, rather than too few. It is difficult to correct the problem after conductors are installed and in service. Failure to accommodate expansion/contraction may result in pipe fracture. 5 6 (10') (20') (10') (20') (10') (20') (10') (20') (10') (20') (10') (20') (10') (20') (10') (20') (10') (20') (10') (20') (10') (20') (10') (20') 032105 032106 032107 032108 032110 032111 032112 032114 032115 032116 032120 032121 032125 032126 032130 032131 032135 032136 032140 032141 032150 032151 032160 032161 OD ID Min. Wall Weight Standard lbs/100' ft/crate 0.840 0.622 0.109 15 1.050 0.824 0.113 21 1.315 1.049 0.133 31 1.660 1.380 0.140 42 1.900 1.610 0.145 53 2.375 2.067 0.154 71 2.875 2.469 0.203 112 3.500 3.068 0.216 166 4.000 3.548 0.226 200 4.500 4.026 0.237 236 5.563 5.047 0.258 321 6.625 6.065 0.280 417 6,000 12,000 4,400 8,800 3,600 7,200 3,300 6,600 2,250 4,500 1,400 2,800 780 1,560 780 1,560 630 1,260 600 1,200 230 460 260 520 Scepter Rigid PVC Conduit Dimensions (mm) Nominal Size OD ID Min. Wall Weight kgs/100' 12 20 25 32 40 50 65 75 90 100 125 150 21.3 26.7 33.4 42.2 48.3 60.3 73.0 88.9 101.6 114.3 141.3 168.3 15.8 20.9 26.6 35.1 40.9 52.5 62.7 77.9 90.1 102.3 128.2 154.1 2.8 2.9 3.4 3.6 3.7 3.9 5.2 5.5 5.7 6.0 6.6 7.1 22.6 31.2 46.2 63.0 78.4 105.5 167.2 247.8 297.7 352.4 478.5 621.0 SCEPTER PVC CONDUIT SCEPTER PVC CONDUIT 14 SCEPTER PVC CONDUIT 16 SCEPTER ® CONDUIT FITTINGS CONDUIT DIMENSIONS 17 Weight Comparison of Scepter Rigid PVC Conduit - lbs./100 ft. Nominal Size (in) Rigid PVC Aluminum Rigid Steel 1/2 15 28 79 3/4 21 27 105 31 53 153 42 70 201 1-1/2 53 86 249 2 71 116 334 2-1/2 112 183 527 3 166 239 690 3-1/2 200 288 831 4 236 340 982 5 321 465 1,334 6 417 613 1,771 SCEPTER PVC FITTINGS 1 1-1/4 Weight Comparison of Scepter Rigid PVC Conduit - kg/100 m Nominal Size (in) Rigid PVC Aluminum Rigid Steel 12 23 41 118 20 31 54 157 25 46 79 228 32 63 104 300 40 78 129 371 50 106 173 498 65 167 272 786 75 248 356 1,029 90 298 429 1,239 100 352 507 1,464 125 479 694 1,989 150 621 914 2,641 CSA C22.2 No. 211.2 FT-4 for 1/2 " to 6" NEMA TC2 Corps. of Engineers Spec. CE 303:01 Military Spec, Federal Spec. WC 1094A Industry leaders specify Scepter PVC fittings by name. For years, Scepter PVC fittings have set the standard for quality and value-added features not normally available from other suppliers. Features such as our threaded brass inserts, brass screws, and superior PVC gasketing system make a real difference. C22.2 No. 85 UL Listed UL514B – UL514C NEMA TC-2, 3 18 19 FITTINGS FITTINGS C B A B Size (in) Part Number Product Code A (in) B (in) C (in) 1/2 EC10 077001 1.080 0.840 1.437 1/2 FA10 3/4 EC15 077002 1.300 1.050 2.200 1/2 FA10 1 EC20 077003 1.590 1.315 2.031 3/4 1-1/4 1-1/2 2 2-1/2 3 3-1/2 4 5 6 EC25 EC30 EC35 EC40 EC45 EC50 EC55 EC60 EC65 C Female Adapters 077004 077005 077006 077007 077008 077009 077010 077011 077012 2.000 2.230 2.720 3.320 4.000 4.500 5.000 6.120 7.370 1.660 1.900 2.375 2.875 3.500 4.000 4.500 5.563 6.625 A D Part Product Size (in) Number Code A (in) B (in) C (in) D (in) 076544 0.620 1.080 0.800 1.725 077041 0.620 1.080 0.800 1.725 FA15 077042 0.820 1.300 0.800 1.900 2.156 1 FA20 077043 1.065 1.590 1.000 2.300 2.281 1-1/4 FA25 077044 1.395 2.000 1.015 2.425 2.406 1-1/2 FA30 077045 1.575 2.230 1.050 2.440 3.187 2 FA35 077046 2.050 2.720 1.075 2.550 3.437 2-1/2 FA40 077047 1.020 3.250 1.500 2.700 3.625 3 FA45 077048 3.090 4.000 1.630 4.100 3.750 3-1/2 FA50 077049 3.540 4.500 1.800 3.895 4 FA55 077050 4.025 5.000 1.755 4.210 5 FA60 077051 5.035 6.120 2.065 5.240 6 FA65 077052 6.045 7.370 2.065 5.235 4.187 4.562 Note: All female adapters have NPT-tapered threads. Terminal Adapters Part Product Size (in) Number Code 5° Couplings A (in) B (in) C (in) D (in) 1/2 TA10 077021 0.700 0.591 0.750 1.550 3/4 TA15 077022 0.675 0.790 1.000 1.750 1 TA20 077023 0.625 1.000 1.115 1.860 1-1/4 TA25 077024 0.640 1.311 1.300 2.125 1-1/2 TA30 077025 0.725 1.530 1.425 2.250 2 TA35 077026 0.800 1.970 1.150 2.100 2-1/2 TA40 077027 0.800 2.346 1.900 2.930 3 TA45 077028 0.815 2.915 2.000 3.055 3-1/2 TA50 077029 1.000 3.385 1.715 3.055 4 TA55 077030 0.815 3.850 1.990 3.215 5 TA60 077031 1.725 5.015 2.000 5.985 6 TA65 077032 1.875 6.025 2.130 6.500 Note: 1/2" to 1-1/4" TA – tapered thread. 1-1/2" to 6" TA – non-tapered thread. Size (in) Part Number Product Code L (in) 2 5EC35 077100 4.0 2-1/2 5EC40 077101 5.5 3 5EC45 077103 6.0 3-1/2 5EC50 077102 7.0 4 5EC55 077104 7.0 5 5EC60 077105 7.5 6 5EC65 077106 11.0 Threaded Reducer Bushings Size (in) Part Number Product Code 3/4 x 1/2 1825 077314 1 x 1/2 1826 077315 1 x 3/4 1827 077316 SCEPTER PVC FITTINGS SCEPTER PVC FITTINGS Couplings 20 FITTINGS 21 FITTINGS “O” Ring Expansion Joints Reducer Bushings Part Number Product Code 3/4 x 1/2 1805 077300 1 x 1/2 1805-1 077301 1 x 3/4 1806 077302 1-1/4 x 3/4 1807-1 077303 1-1/4 x 1 1807 077304 1-1/2 x 1 1808-1 077305 1-1/2 x 1-1/4 1808 077306 2x1 1809-1 077313 2 x 1-1/4 1809 077307 2 x 1-1/2 1810 077308 2-1/2 x 2 1811 077309 3x2 1812-1 077310 3 x 2-1/2 1812 077311 4x2 1813-1 077319 4x3 1813 077312 4 x 3-1/2 1814 077317 B min. A max. Size (in) Part Number Product Code A (in) max. B (in) min. 1/2 EJ10 077381 12.00 8.00 3/4 EJ15 077382 12.00 8.00 1 EJ20 077383 12.50 8.50 1-1/4 EJ25 077384 13.00 9.00 1-1/2 EJ30 077385 13.00 9.00 2 EJ35 077386 13.25 9.25 2-1/2 EJ40 077387 13.25 9.25 3 EJ45 077388 22.25 14.25 3-1/2 EJ50 077389 22.25 14.25 4 EJ55 077390 22.25 14.25 5 EJ60 077391 22.25 14.25 6 EJ65 077392 22.25 14.25 Expansion and Deflection Fitting Assemblies *Additional sizes of reducer bushings are available upon request. End Caps Size (in) Part Number Product Code 1/2 CAP10 077421 3/4 CAP15 077422 1 CAP20 077423 1-1/4 CAP25 077424 1-1/2 CAP30 077425 2 CAP35 077426 2-1/2 CAP40 077427 3 CAP45 077428 3-1/2 CAP50 077429 4 CAP55 077430 5 CAP60 077431 6 CAP65 077432 Size (in) Part Number Description Product Code 2 SE-J-35 Complete Assembly 077889 3 SE-J-45 Complete Assembly 077890 4 SE-J-55 Complete Assembly 077891 R T Utility 90° Elbows c/w Solvent Bell End D Size (in) Part Number Product Code D (in) T (in) R (in) 2 NSL 2-24 069257 2.375 41.20 24 2 NSL 2-36 069260 2.375 31.70 36 3 NSL 3-24 069265 3.500 41.20 24 3 NSL 3-36 069261 3.500 31.70 36 4 NSL 4-36 069267 4.500 31.70 36 4 NSL 4-48 069266 4.500 22.25 48 5 NSL 5-36 069263 5.563 31.70 36 6 NSL 6-36 069264 6.625 31.70 36 SCEPTER PVC FITTINGS SCEPTER PVC FITTINGS Size (in) FITTINGS 23 FITTINGS T 22 R 90° Elbows 30° Elbows With integral bell. c/w Solvent Bell End (Plain End x Plain End) Part Number Product Code D (in) T (in) R (in) 1/2 EE1090 069081 0.840 1.500 4.00 3/4 EE1590 069082 1.050 1.500 4.50 1 EE2090 069083 1.315 1.875 5.75 1-1/4 EE2590 069084 1.660 2.000 7.25 1-1/2 EE3090 069085 1.900 2.000 8.25 2 EE3590 069086 2.375 2.000 9.50 2-1/2 EE4090 069087 2.875 3.000 10.50 3 EE4590 069088 3.500 3.125 13.00 3-1/2* EE5090 069089 4.000 3.250 15.00 4 EE5590 069090 4.500 3.375 16.00 5 EE6090 069091 5.563 3.625 24.00 6 EE6590 069092 6.625 3.750 30.00 Size (in) Part Number Product Code D (in) T (in) R (in) 1/2 3/4 1 1-1/4 1-1/2 2 2-1/2 3 3-1/2 4 5 6 EE1030 EE1530 EE2030 EE2530 EE3030 EE3530 EE4030 EE4530 EE5030 EE5530 EE6030 EE6530 069241 069242 069243 069244 069245 069246 069247 069248 069249 069250 069251 069252 0.840 1.050 1.315 1.660 1.900 2.375 2.750 3.500 4.000 4.500 5.563 6.625 1.500 1.500 1.875 2.000 2.000 2.000 3.000 3.125 3.250 3.375 3.625 3.750 4.00 4.50 5.75 7.25 8.25 9.50 10.50 13.00 15.00 16.00 24.00 30.00 * Plain end only R T Utility 90° Elbows c/w Solvent Bell End D Size (in) 45° Elbows c/w Solvent Bell End With integral bell. Size (in) Part Number Product Code D (in) T (in) R (in) 1/2 EE1045 069201 0.840 1.500 4.00 3/4 EE1545 069202 1.050 1.500 4.50 1 EE2045 069203 1.315 1.875 5.75 1-1/4 EE2545 069204 1.660 2.000 7.25 1-1/2 EE3045 069205 1.900 2.000 8.25 2 EE3545 069206 2.375 2.000 9.50 2-1/2 EE4045 069207 2.875 3.000 10.50 2 2 3 3 4 4 5 6 Part Number Product Code D (in) T (in) R (in) NSL NSL NSL NSL NSL NSL NSL NSL 069257 069260 069265 069261 069267 069266 069263 069264 2.375 2.375 3.500 3.500 4.500 4.500 5.563 6.625 10.200 31.700 41.200 31.700 31.700 31.700 31.700 31.700 24.00 36.00 24.00 36.00 36.00 48.00 36.00 36.00 2-24 2-36 3-24 3-36 4-36 4-48 5-36 6-36 3 EE4545 069208 3.500 3.125 13.00 3-1/2* EE5045 069209 4.000 3.250 15.00 90° Elbows 4 EE5545 069210 4.500 3.375 16.00 Extended bend 5 EE6045 069211 5.563 3.625 24.00 6 EE6545 069212 6.625 3.750 30.00 * Plain end only 90º Size (in) Part Number Product Code D (in) T (in) R (in) 1-1/4 1-1/2 2 EE2590E EE3090E EE3590E 069096 069097 069098 1.66 1.90 2.38 10.24 12.80 11.02 6.73 8.25 13.00 SCEPTER PVC FITTINGS SCEPTER PVC FITTINGS D Size (in) 24 25 FITTINGS PVC Coated Steel, 1 Hole Size (in) Part Number Product Code Size (in) Part Number Product Code 1/2 PS10 077811 1/2 CS10-1 077831 3/4 PS15 077812 3/4 CS15-1 077832 1 PS20 077813 1 CS20-1 077833 1-1/4 PS25 077814 1-1/4 CS25-1 077834 1-1/2 PS30 077815 1-1/2 CS30-1 077835 2 PS35 077816 2 CS35-1 077836 2-1/2 CS40-1 077837 3 CS45-1 077838 3-1/2 CS50-1 077839 4 CS55-1 077840 SCEPTER PVC FITTINGS SCEPTER PVC FITTINGS Pipe Straps PVC, 2 Hole Polyethylene (PE), 2 Hole Size (in) Part Number Product Code 2-1/2 PS40 077262 3 PS45 077263 4 PS55 077264 PVC Coated Steel, 2 Hole Size (in) Part Number Product Code 2 CS35 077818 2-1/2 CS40 077819 3 CS45 077820 3-1/2 CS50 077821 4 CS55 077822 5 CS60 077824 6 CS65 077823 Conduit Clamps & Spacers Size (in) Part Number Product Code X (in) Y (in) Z (in) 1/2 CCS10 077794 1.191 2.414 1.824 3/4 CCS15 077796 1.195 2.660 2.106 1 CCS20 077797 1.215 2.962 2.443 1-1/4 CCS25 077798 1.182 3.300 2.855 1-1/2 CCS30 077799 1.193 3.600 3.170 2 CCS35 077800 1.195 4.135 3.785 Strut Base CCS-B 077343 _ _ _ * CCS-B are sold individually, two pieces are required to create one base unit. Y X Z FITTINGS 26 Access Fittings* Type LB Access Fittings* Type LL F G C F H H G B B E I B K 27 FITTINGS TYPE LL C E I Size (in) Part Number Product Code Size (in) Part Number Product Code 1/2 SLB10S 077541 1/2 SLL10S 077521 077542 3/4 SLL20S 077522 077543 1 SLL30S 077523 077544 1-1/4 SLL40S 077524 077545 1-1/2 SLL50S 077525 077546 2 SLL60S 077526 077547 2-1/2 SLL70S 077527 077548 3 SLL80S 077528 077549 3-1/2 SLL90S 077530 077550 4 SLL100S 077529 3/4 SLB20S 1 SLB30S 1-1/4 SLB40S 1-1/2 SLB50S 2 SLB60S 2-1/2 SLB70S 3 SLB80S 3-1/2 SLB90S 4 SLB100S Access Fittings* Type LR Access Fittings* Type C H G B B C E E C D I B B A F Size (in) 1/2 3/4 1 1-1/4 1-1/2 2 2-1/2 3 3-1/2 4 Part Number SLR10S SLR20S SLR30S SLR40S SLR50S SLR60S SLR70S SLR80S SLR90S SLR100S Product Code Size (in) Part Number Product Code 077481 1/2 SC10S 077501 077482 3/4 SC20S 077502 077483 1 SC30S 077503 077484 1-1/4 SC40S 077504 077485 1-1/2 SC50S 077505 077486 2 SC60S 077506 077480 2-1/2 SC70S 077507 077488 3 SC80S 077508 077487 3-1/2 SC90S 077510 077489 4 SC100S 077509 * All access fittings are CSA and UL listed for wet locations. Supplied with threaded brass inserts, combination brass head screws and PVC gasketing. * Stainless steel screws are available upon request. **Not UL Listed. SCEPTER PVC FITTINGS SCEPTER PVC FITTINGS B FITTINGS 28 Access Fittings* Type T Access Fittings* Type TB** J K B J 29 FITTINGS E C D I D E B B L J B J Size (in) Part Number Product Code Size (in) Part Number Product Code 1/2 STB10S 077451 1/2 ST10S 077461 3/4 STB20S 077452 3/4 ST20S 077462 1 STB30S 077453 1 ST30S 077463 1-1/4 STB40S 077454 1-1/4 ST40S 077464 1-1/2 STB50S 077455 1-1/2 ST50S 077465 2 STB60S 077456 2 ST60S 077466 2-1/2 ST70S 077467 3 ST80S 077468 3-1/2 ST90S 077571 Size (in) A (in) B (in) C (in) D (in) E (in) F (in) 4 ST100S 077572 1/2 5.606 0.639 1.268 1.100 0.840 4.337 3/4 5.606 0.810 1.536 1.325 1.050 5.395 1 6.500 0.910 1.700 1.600 1.335 6.250 1-1/4 7.900 1.050 2.300 2.250 1.660 7.625 1-1/2 8.500 1.125 2.675 2.250 1.900 8.250 2 10.875 1.160 3.188 2.820 2.375 10.531 2-1/2 14.600 1.750 4.500 3.950 2.870 13.630 3 14.600 1.900 4.500 3.950 3.510 13.630 3-1/2 17.040 2.125 5.536 5.000 4.000 16.000 4 17.040 2.125 5.536 5.000 4.530 16.000 Access Fittings* Type E F C E B Access Fitting Dimensions* Size (in) Part Number Product Code 1/2 SE10S 077561 Size (in) G (in) H (in) I (in) J (in) K (in) L (in) 3/4 SE20S 077562 1/2 4.095 1.297 2.487 2.280 1.005 0.750 1 SE30S 077563 3/4 4.095 1.297 2.487 2.803 1.005 0.810 1-1/4 SE40S 077564 1 4.750 1.500 2.075 3.250 1.125 1.115 1-1/2 SE50S 077565 1-1/4 5.750 1.750 3.575 3.950 1.562 1.300 2 SE60S 077566 1-1/2 6.500 1.750 3.938 4.250 1.656 1.425 2-1/2 SE70S 077567 2 8.156 2.344 4.535 5.438 1.968 1.160 3 SE80S 077568 2-1/2 9.825 3.805 6.240 7.300 2.610 - 3-1/2 SE90S 077569 3 10.897 2.733 6.240 7.300 2.610 - 4 SE100S 077570 3-1/2 11.465 4.535 7.500 8.535 2.975 - 4 11.465 4.535 7.500 8.535 2.975 - * All access fittings are CSA and UL listed for wet locations. Supplied with threaded brass inserts, combination brass head screws and PVC gasketing. * Stainless steel screws are available upon request. **Not UL Listed. * All access fittings are CSA and UL listed for wet locations. Supplied with threaded brass inserts, combination brass head screws and PVC gasketing. * Stainless steel screws are available upon request. **Not UL Listed. SCEPTER PVC FITTINGS SCEPTER PVC FITTINGS B 30 FITTINGS Meter Hubs End Bells Product Code Size (in) Part Number Product Code EB-10 077406 1-1/4 MHU25 077961 EB-15 077085 1-1/2 MHU30 077963 1 EB-20 077323 2 MHU35 077965 1-1/4 EB-25 077324 2-1/2 MHU40 077967 1-1/2 EB-30 077325 3 MHU45 077968 2 EB-35 077326 2-1/2 EB-40 077327 3 EB-45 077328 3-1/2 EB-50 077329 4 EB-55 077330 5 EB-60 077331 6 EB-65 077332 Size (in) Part Number 1/2 3/4 Long Meter Offsets (Fabricated) Size (in) Part Number Product Code 1-1/4 LMO25 069641 1-1/2 LMO30 069645 2 LMO35 069646 Service Entrance Fittings Size (in) Part Number Product Code 1/2 EF10 077281 3/4 EF15 077282 “Two in One” Pull Elbow The “two in one” access pull elbow reduces inventory costs & increases installation flexibility (3/4" hub fitting supplied with 3/4" x 1/2" reducers). The pull elbow is approved for wet location use and is manufactured from high impact, nonconducting and noncorroding PVC. 1 EF20 077283 1-1/4 EF25 077284 1-1/2 EF30 077285 2 EF35 077286 2-1/2 EF40 077287 Size (in) Part Number Product Code 3 EF45 077288 1/2 or 3/4 PE15/10 077491 3-1/2 EF50 077289 4 EF55 077290 Size (in) Part Number Product Code 1-1/4 MO25 077941 2 MO35 077942 Meter Offsets SCEPTER PVC FITTINGS SCEPTER PVC FITTINGS 31 FITTINGS FITTINGS Nonmetallic Threaded Strain Relief Connector c/w “O” Ring, Locknut & 6 Grommets F Series - Single Gang Plates 1.415” dia. DRC15/10 TSC15/10 1.610” dia. 1.760” dia. 20RC15/10 20-3RC15/10 30-3RC15/10 BRC15/10 Size (in) Part Number Product Code Part Number Product Code 1/2 TSRC10 077754 Duplex Receptacle DRC15/10 077617 3/4 TSRC15 077756 Toggle Switch TSC15/10 077616 Single Receptacle 20RC15/10 077618 Single Receptacle 20-3RC15/10 077619 Single Receptacle 30RC15/10 077620 Blank c/w Gasket BRC15/10 077611 PVC Gasket GASK15/10 077621 Description Strain Relief Connectors c/w 6 Grommets Part Number Product Code 3/4 SRC15 077985 F Series - Double Gang Plates GASK20-2 Size (in) Strain Relief Connectors Grommet Dimensions BRC20-2 Grommet From TSC20-2 To Description W = .195" L = .450" W = .220" W = .285" L = .530" W = .291" L = .516" L = .565" Ø = .240" Ø = .300" Ø = .290" Ø = .385" DRC20-2 TSDC20-2 Part Number Product Code Blank Cover c/w Gasket BRC20-2 077614 Double Switch TSC20-2 077738 Double Duplex Receptacle DRC20-2 077740 Combo Switch Duplex Rec. TSDC20-2 077739 PVC Gasket GASK20-2 077743 GASK20-3 F Series - Triple Gang Plates BRC20-3 DRC20-3 Description Ø = .500" Note: All grommets are supplied with TSRC10, TSRC15 and SRC15. Ø = .625" TSDC20-3 Product Code DRC20-3 077747 DSDR20-3 077745 TSC20-3 077744 Combo Switch Receptacle TSDC20-3 077746 Blank Cover c/w Gasket BRC20-3 077748 PVC Gasket GASK20-3 077749 Combo Switch Receptacle Triple Switch Ø = .525" TSC20-3 Part Number Triple Receptacle Ø = .405" DSDR20-3 SCEPTER PVC FITTINGS SCEPTER PVC FITTINGS 33 COVER PLATES GASK 15/10 32 WEATHERPROOF COVERS 34 Weatherproof Covers - Single Gang VPT15/10 Description (in) Weatherproof Covers - Double Gang Part Number Product Code VPT15/10 077630 Description Part Number Product Code Toggle Switch Cover VSC20-2 077741 Combination Switch & GFI Receptacle VSRC20-2 077742 Combination Switch & Duplex Receptacle VSDR20-2 077752 Combination Switch & Single Receptacle Cover VSRR20-2 077753 Double Door GFCI Cover VSGG20-2 077096 Double Door Duplex Cover VSDD20-2 077097 GASK20-2 077743 VSC20-2 Plunger-style Switch Cover VSC15/10 Toggle Switch Cover VSC15/10 SCEPTER PVC FITTINGS SCEPTER PVC FITTINGS 35 WEATHERPROOF COVERS 077612 VSRC20-2 WTG15/10 WDR15/10 RWDR15/10 WGF15/10 RWGF15/10 WTL15 WTL20 WTL30 Grey Toggle Switch Cover WTG15/10 077606 Grey Duplex Receptacle WDR15/10 077993 White Duplex Receptacle RWDR15/10 077786 Grey Ground Fault Receptacle WGF15/10 077785 White Ground Fault Receptacle RWGF15/10 077787 WTL15 077992 Single Receptacle Device 15 AMP VSDR20-2 1.375 Single Receptacle Device 20 AMP 1.625 WTL20 077994 Single Receptacle Device 30 AMP 1.722 WTL30 077991 Single Receptacle Device 50 AMP 2.187 WTL50 077951 Grey Double Door Duplex Receptacle WDRE15/10 077087 White Double Door Duplex Receptacle RWDRE15/10 077408 VSRR20-2 VSGG20-2 VSDD20-2 WTL50 WDRE15/10 RWDRE15/10 Gasket for W Series Cover (except WDRE & (except VSGG20-2 & VSDD20-2) GASKW 077755 GASKDD 072225 RWDRE) Gasket for WDRE & RWDRE Covers Gasket for 2-Gang ‘F’ Boxes Note: Weatherproof covers, with lids closed, are CSA and UL Listed for wet locations. Gasket for VSGG20-2 & VSDD20-2 Double Gangs GASKV20-2 072227 BOXES 36 37 BOXES F Series Single Gang Boxes F Series Double Gang Boxes Outside Dimensions: Height, 49/16" – Width, 213/16" – Depth 2", Cubic Inches = 25.67 FS-2 cu.in = 39.5, FSC-2 & FSS-2 cu.in. = 37.0, FSCC-2 cu.in.= 36.0 FS-2-101520 1/2, 3/4, 1 FSC-2-101520 077441 4.5 4.75 2.5 1/2, 3/4, 1 FSS-2-101520 077442 4.5 4.75 SCEPTER PVC FITTINGS FSC FSS FSCC FS 2.5 1/2, 3/4, 1 FSCC-2-101520 077443 4.5 4.75 2.5 Blank FD-2 077734 4.75 4.75 Size (in) Part Number Product Code 3.0 1/2 FSC10 077607 3/4 FSC15 077608 1/2 FS10 077601 3/4 FS15 077602 1/2 FSCC10 077622 3/4 FSCC15 077623 1/2 FSS10 077604 3/4 FSS15 077605 Part Number H 4.5 OD (inches) W D 4.75 2.5 W H D FSC-2-101520 FS-2-101520 FSCC-2-101520 FSS-2-101520 FD-2 Note: 10 = 1/2" Hub, 15 = 3/4" Hub FD Series Single Gang Deep Boxes Outside Dimensions: Height, 49/16" – Width, 213/16" – Depth 23/4", Cubic Inches = 35.30 With the exception of the FD Blank Box, Scepter FD Series Single Gang Deep Boxes are molded with 1" conduit hubs and supplied with reducer bushings. The conduit hub(s) are field modified as 1/2", 3/4" or 1" to accommodate job-site requirements. The appropriate quantity of 1" x 3/4" and 3/4" x 1/2" reducers to create the desired hub size are packaged with each FD Series Single Gang Deep Box. FD Blank FDS101520 F Series Triple Gang Boxes 1/2, 3/4, 1 FS-3-101520 Product Code 077337 1/2, 3/4, 1 FSC-3-101520 077438 4.5 6.6 2.5 Blank FD-3 077737 4.5 6.6 3.0 Hub Size (in) Part Number H 4.5 OD (inches) W D 6.6 2.5 Note: All F series boxes are supplied with integral mounting feet, threaded brass inserts and grounding clips. FDC101520 H W D FS-3-101520 Size (in) Part Number Product Code 1/2, 3/4, 1 FDC101520 077291 1/2, 3/4, 1 FDS101520 077299 BLANK FD BLANK 077603 347 VOLT FD347 077610 FSC-3-101520 FD-3 SCEPTER PVC FITTINGS 1/2, 3/4, 1 Product Code 077440 Hub Size (in) 38 Flanged Box with Fibre-Reinforced Safety Tread Cover Octagonal Boxes* Octagonal Boxes are shipped complete with cover, gasket, 4 reducing bushings (3/4" x 1/2") and 4 sealing caps to be installed from inside box to seal off unused entry hubs. Scepter’s Flanged ‘H’ Series Junction Boxes provide H10 Highway Loading. The fiber-reinforced safety tread cover secures using recessed Hex Key fastening hardware offering a simple installation while reducing the opportunity for tampering. Size (in) Part Number Hub Size (in) Product Code 4 x 1-1/2 OB15/10 1/2 – 3/4 077983* 4 x 2-1/8 OB20 1 077984* H887 H887A CC B A Octagonal Box Extension Rings Size (in) Part Number Product Code 4 x 1 deep XR20 077989* 4 x 2 deep XR35 077990* * Octagonal Boxes are not designed for supporting luminaires. PVC Molded Junction Boxes Junction boxes are supplied with threaded brass inserts, brass screws, PVC gasketing and mounting feet. Nylon and stainless steel screws, as well as larger sizes of fabricated junction boxes, are available upon request. L Box ID (in) W D B C NEMA 1, 2, 3, 4, 4x, 6P, 12, 13 UL listed for wet locations H664 077685 6 6 4-1/4 9.0 9.0 0.60 H666 077686 6 6 6-1/4 9.0 9.0 0.60 H884 077687 8 8 4-1/4 11.5 11.5 0.75 H886 077688 8 8 6-1/4 11.5 11.5 0.75 H887 077689 8 8 7-1/4 11.5 11.5 0.75 H887-A 077692 8 8 7-1/4 11.5 11.5 0.75 BC E (in) Junction Box Adapters A F C (in) D E Size (in) A E (in) Part Number Product Code 1/2 JBA10 077721 F (in) 3/4 JBA15 077722 1 JBA20 077723 Part Number Product Code JB442 077659 3.675 4.000 3.450 2.125 2.000 8-32 1-1/4 JBA25 077724 JB444 077696 3.675 4.000 3.450 4.188 3.750 8-32 1-1/2 JBA30 077725 JB446 077669 3.675 4.000 3.450 6.225 6.000 8-32 2 JBA35 077726 JB552 077670 4.680 5.000 4.485 2.000 1.845 8-32 2-1/2 JBA40 077727 JB664 077697 6.000 6.375 5.813 4.188 4.000 10-32 3 JBA45 077728 JB666 077698 6.000 6.375 5.813 6.188 6.000 10-32 3-1/2 JBA50 077729 JB884 077664 8.075 8.625 7.966 4.230 4.005 1/4-20 4 JBA55 077730 JB887 077671 8.100 8.625 7.966 7.250 7.035 1/4-20 JB12124 Lid Dimensions (in) A B C Unflanged PVC fabricated boxes of any size may be made to customers’ specifications and come complete with lids, gaskets and screws. These boxes are not CSA Certified and are not returnable. Scepter PVC junction boxes are: B (in) Part Number Fabricated Boxes (F = Threaded brass insert size.) A (in) Size (in) 077672 12.085 12.580 11.874 4.256 4.030 1/4-20 JB12126 077666 12.085 12.580 11.874 6.240 6.025 1/4-20 JB12128 077668 12.085 12.580 11.874 8.250 8.025 1/4-20 Junction Box Adapter Standard PVC Coupling SCEPTER PVC FITTINGS SCEPTER PVC FITTINGS 39 BOXES BOXES 40 BOXES Nonmetallic Floor Box, Cover & Metal Cover Adapter Description Installation is quick and simple with our nonmetallic floor box and covers, saving both time and money over similar metallic assemblies. Floor Box Base All boxes are shipped complete with reducer plugs for added versatility. Product Code 076954 FB FB Floor Box Base c/w Leveling Ring Adapter (includes disposable protective cap, reducer plugs & leveling ring adapter) 077068 FBKIT Floor Box Stand Kit (includes FB Box) (is equiped with several height brackets which accommodate the different rebar and post-tension cable heights and slab depths found from job-site to job-site.) 077700 This simple yet innovative Round Floor Box Stand is equipped with several height brackets which accommodate the different rebar and post-tension cable heights and slab depths found from jobsite to job-site. When installed together, the Floor Box and Stand can be used in 5-1/2" to 10" slab depths. Sold as a Kit, IPEX offers the Round Floor Box and Stand conveniently packaged together as one complete product offering. • Raises Entrance Hubs to Rebar • Minimizes Footprint on Concrete Form AFMC (includes leveling ring, metal cover adapter & 2 gaskets) 076953 AFMC Universal Leveling Ring Adapter 076606 LRA-U LRA-U Floor Box Duplex Receptacle Cover (Nonmetallic) (includes flush mount cover, blank cover & gasket) Brown Gold Grey Light Almond 076943 076942 076941 076940 FBDRCB FBDRCG FBDRCGr FBDRCA FBDRC Tri-Service Universal Divider Kit (includes upper & lower dividers, riser tube & two grommets) 077948 FBUDK 077499 FBYC FBUDK Y Connector (3/4") FEATURE & BENEFITS • Four Adjustable Heights FBS-KIT FBS-KIT Metal Cover Adapter Kit One Kit, Four Heights, One Low Cost! SCEPTER PVC FITTINGS The flush-mount covers are available in custom colours and are shipped with a leveling ring complete with a grounding clip. Metal cover adapter kits are also available, allowing you to adapt to metal floor plates. Our 6" deep floor box allows flexibility for various concrete floor pours, while the 4 3/4" width offers easy access and ample wire room. Scepter’s FB box is molded with 2 - 1" and 2 - 3/4" hub openings. Part Number (Includes disposable protective cap & reducer plugs) Scepter’s floor box and duplex receptacle covers are constructed from high impact, noncorroding and nonconducting PVC. SCEPTER PVC FITTINGS 41 BOXES • Withstands Tough Job Site Conditions Brass Cover Plates • Easy to Install (offers a one-piece design measuring 5-3/4" diameter. Are available in a variety of styles accommodating power and communication needs. Install to the FB box using the universal leveling ring adapter. • Cost Effective For more information, visit our NEW website www.ipexelectrical.com Duplex Screw Cover Duplex Screw Cover Single Screw Cover Single Screw Cover Duplex Flip Lid (single) Duplex Flip Lid (double) DSC DSC-P/C SSC SSC-P/C DFL-1 DFL-2 178091 178092 178093 178094 178095 178096 FBYC 43 CONDUIT REPAIR KIT 42 Conduit Cement c/w Applicator Cap Conduit Repair Kit Part Number Product Code 125ml S100PT25 074717 250ml S100PT5 074713 500ml S100PT 074714 1L S100QT 074715 4L S100GAL 074716 Size Part Number Product Code SCEPTER PVC FITTINGS Size EPR Kit for Conduit Repair EPR Kits from IPEX are the first total repair systems for broken and damaged PVC conduit. They offer fast and easy repairs for damaged conduit caused by actions such as earth excavation, horizontal and core drilling. All sizes are 24 inches in length. Primer C100PT5 500ml 074306 C100PT 1L 074307 C100QT 074308 Average # of Joints per Pint or Quart of Cement Nominal Pipe Size # of Joints # of Joints Nominal Pipe Size # of Joints # of Joints inches mm /Pint /Quart inches mm /Pint /Quart 1/2 12 350 700 2-1/2 12 40 80 3/4 19 200 400 3 19 35 70 1 25 150 300 3-1/2 25 30 60 1-1/4 32 110 220 4 32 24 48 1-1/2 38 80 160 5 38 10 20 2 50 45 90 6 50 8 16 Part Number Product Code 1-1/4 EPR25 077976 1-1/2 EPR30 077971 2 EPR35 077972 2-1/2 EPR40 077973 3 EPR45 077974 4 EPR55 077975 5 EPR60 077977 6 EPR65 077979 EPR Kit Adapters for Duct Repair EPR Conduit Repair Kits allow contractors to repair a broken section of DB-II duct while leaving the cables inside. The Adapters are pre-cut allowing each to open around existing cabling and are then solvent cemented onto the outside diameter of the broken duct. Using standard PVC solvent cement, an EPR Kit is then easily assembled and connected to the Adapters, restoring the duct to its original form. Size (in) Part Number Product Code 2 EPRA35 077852 3 EPRA45 077853 4 EPRA55 077854 5 EPRA60 077855 6 EPRA65 077856 CONDUIT REPAIR KIT 250ml Size (in) SCEPTALIGHT Bookmark Our New Website www.ipexelectrical.com TM 45 SCEPTALIGHT: The Light That Lasts Sceptalight fixtures from IPEX prove themselves to be all-round performers in a variety of indoor and outdoor applications. PRODUCT INFO, TECHNICAL DOCUMENTS, ONLINE TRAINING & MUCH MORE ... Sceptalight's thermoplastic construction offers outstanding corrosion and chemical resistance. And its interior and exterior silicone gaskets create a watertight seal, the reason it performs equally well indoors and outside. Features and Benefits • Stable Construction • Watertight seal with weather-resistant silicone gaskets • Corrosion Resistant • Durable and Impact Resistant OUR SCEPTER ELECTRICAL CATALOGUE & ELECTRICAL POCKET PRO INCLUDE MORE INFORMATION ON: • Conduit & Fittings • Light Fixtures • ENT Tubing & Fittings Mounting Options CEILING MOUNT WALL MOUNT Box with four 3/4" threaded hubs and integral mounting feet. Box with four 3/4" threaded hubs, 90º wall bracket and integral mounting feet. PENDANT MOUNT • Duct • Trenchless Raceways • and much more ... available at www.ipexelectrical.com Pendant cap with 3/4" threaded hub and a locking set screw. SCEPTALIGHT Sceptalight fixtures are made from a glass-reinforced thermoplastic polyester resin, which enable them to stand up better to corrosive elements than metal. This thermoplastic design marries an unrivaled balance of strength, stiffness and toughness with all the benefits users appreciate of Scepter rigid PVC conduit and fittings - long life, easy servicing and high impact-resistance. 46 SCEPTALIGHT SCEPTALIGHT TM Globe Options Wet Locations Sceptalight offers a variety of globe options to suit a wide range of applications and environments. Our standard clear glass globes are ideal for general purpose area lighting for either indoor or outdoor use. Polycarbonate globes offer impact resistance in case of accidental contact and the assurance that work areas are not contaminated by broken glass. Coloured globes - available in red, blue, green or amber can transform the light to an indicator or warning light. C22.2 No. 250 UL 1598 Ceiling Mount 4 3/4" Ceiling Mount Ceiling Mount Heat-treated Blue Glass Heat-treated Green Glass Heat-treated Amber Glass Light Options Fluorescents Our compact fluorescent fixtures work four to five times more efficiently per watt than incandescents and provide 10-20 times the lamp life, yet use approximately 75% less energy. In this way, Sceptalight fluorescents lower energy and maintenance costs without sacrificing light levels. Incandescents With their low initial cost, Sceptalight incandescent fixtures make the most practical choice to meet the daily needs of commercial, industrial, marine and agricultural applications. Our incandescents are ideal for short burn times as well as flashing and dimming applications. Ceiling Mount Polycarbonate Globe Part Number Product Code 150W Incandescent LVPF150C 077225 150W Incandescent less guard LVPF150LG 077237 26W Compact Fluorescent LVPL26C 077170 18W Compact Fluorescent LVPL18C 077210 13W Compact Fluorescent LVPL13C 077122 9W Compact Fluorescent LVPL9C 077121 7W Compact Fluorescent LVPL7C 077120 Part Number Product Code Ceiling Mount with Clear Polycarbonate Glass Globe (no guard) 26W Compact Fluorescent LVPL26PCC 077176 18W Compact Fluorescent LVPL18PCC 077211 13W Compact Fluorescent LVPL13PCC 077165 9W Compact Fluorescent LVPL9PCC 077155 7W Compact Fluorescent LVPL7PCC 077145 SCEPTALIGHT SCEPTALIGHT Heat-treated Red Glass 9 1/2" 10" Ceiling Mount with Standard Clear Glass Globe Standard or Heat-treated Clear Glass 6" 4 3/4" 11 3/4" Clear Polycarbonate 47 TM 48 SCEPTALIGHT SCEPTALIGHT TM Pendant Mount Hazardous Locations 4 3/4" 4 3/4" 49 TM Class I, Div 2 Groups A, B, C & D Class II, Div 2 Groups F & G Ceiling Mount 10 1/4" 12" Part Number Product Code 150W Incandescent clear LVPF150HRC-HAZ 077414 Part Number Product Code 150W Incandescent red LVPF150HRR-HAZ 077415 150W Incandescent blue LVPF150HRB-HAZ 077416 150W Incandescent LPMF150C 077231 150W Incandescent green LVPF150HRG-HAZ 077417 26W Compact Fluorescent LPPL26C 077184 150W Incandescent amber 18W Compact Fluorescent LPPL18C 077212 13W Compact Fluorescent LPPL13C 077185 9W Compact Fluorescent LPPL9C 077183 7W Compact Fluorescent LPPL7C 077182 Pendant Mount with Clear Polycarbonate Globe (no guard) Part Number Product Code LVPF150HRA-HAZ 077494 26W Compact Fluorescent clear LVPL26HRC-HAZ 077377 26W Compact Fluorescent red LVPL26HRR-HAZ 077378 077379 26W Compact Fluorescent blue LVPL26HRB-HAZ 26W Compact Fluorescent green LVPL26HRG-HAZ 077399 26W Compact Fluorescent amber LVPL26HRA-HAZ 077400 26W Compact Fluorescent LPPL26PCC 077375 18W Compact Fluorescent clear LVPL18HRC-HAZ 077347 18W Compact Fluorescent LPPL18PCC 077273 18W Compact Fluorescent red LVPL18HRR-HAZ 077348 13W Compact Fluorescent LPPL13PCC 077365 18W Compact Fluorescent blue LVPL18HRB-HAZ 077349 9W Compact Fluorescent LPPL9PCC 077355 18W Compact Fluorescent green LVPL18HRG-HAZ 077353 7W Compact Fluorescent LPPL7PCC 077345 18W Compact Fluorescent amber LVPL18HRA-HAZ 077354 Pendant Mount Wall Mount Pendant Mount with Heat Resistant Glass Globe 7 1/4" 2 7/8" 13 1/4" Part Number Product Code For wall mount fixtures select and order the appropriate style (wattage and globe) ceiling LWB150 mount fixture from above and add LWB150 Wall Mount bracket 077233 Description Part Number Product Code 150W Incandescent clear LPMF150HRC-HAZ 077495 150W Incandescent red LPMF150HRR-HAZ 077496 26W Compact Fluorescent clear LPPL26HRC-HAZ 077407 26W Compact Fluorescent red LPPL26HRR-HAZ 077409 18W Compact Fluorescent clear LPPL18HRC-HAZ 077500 18W Compact Fluorescent red LPPL18HRR-HAZ 077498 Part Number Product Code For wall mount fixtures select and order the appropriate style (wattage and globe) ceiling LWB150 mount fixture from above and add LWB150 Wall Mount bracket 077233 Wall Mount Description SCEPTALIGHT SCEPTALIGHT Pendant Mount with Standard Clear Glass Globe Ceiling Mount with Heat Resistant Glass Globe 50 SCEPTALIGHT SCEPTALIGHT TM Nonmetallic Utility Light Fixture LVPE150-PCC LVPE150 51 TM Accessories & Components * 5 1/8" 5 1/8" Standard Glass Globes 3 1/2" 9 7/8" Part Number Hub Product Size Code LVPE150-10/15 1 Fixture c/w Clear Polycarbonate Globe Fixture c/w Heat Resistant Clear Globe LVPE150-PCC* LVPE150-HRC 1 Fixture c/w Heat Resistant Red Globe LVPE150-HRR 1 Fixture c/w Heat Resistant Blue Globe LVPE150-HRB 1 Fixture c/w Heat Resistant Green Globe LVPE150-HRG 1 Fixture c/w Heat Resistant Amber Globe LVPE150-HRA 1 Nonmetallic Clamp-on Guard Fixture c/w Clear Glass Globe & Clamp-on guard Clear LGC150 077247 Heat Resistant Globes LVPE150-1015G Fixture c/w Clear Glass Globe Replacement Clear Glass Globe Product Code /2"-3/4" 077493 /2"-3/4" 077181 /2"-3/4" 077578 1 /2"-3/4" 077599 /2"-3/4" 077579 /2"-3/4" 077597 /2"-3/4" 077598 LGC150 Description Part Number Product Code Clear LG150T 077909 Red LCGR150T 077239 Blue LCGB150T 077910 Green LCGG150T 077241 Amber LCGA150T 077242 Polycarbonate Globes (for use with compact fluorescent or maximum 60W incandescent lamp) Description Part Number Product Code Clear LPCC18 077911 Red LPCR18 077912 Blue LPCB18 077913 Green LPCG18 077914 Amber LPCA18 077915 077247 LVPUG150 077558 LVPE150-1015G /2"- /4" 077402 1 Threaded Junction Boxes 3 * Maximum 60W incandescent lamp with polycarbonate globe Part Number Product Code LFB150C 077250 LFB150T * 077251 *LFB150T complete with 1/2 threaded" hole in center of cover SCEPTALIGHT Description Part Number 11 SCEPTALIGHT LVPUG150 Description 52 SCEPTALIGHT COR-LINE ® ENT & KWIKON ® FITTINGS TM 53 Accessories & Components con’t Fixture Components (LVPF, LVPL, LPMF, LPPL) Description Part Number Product Code Ceiling Mount Box LVPB 150 077243 Pendant Mount Cap LPC 150 077246 90 Wall Bracket LWB 150 077233 Socket Base Assembly LSBA 150 077245 Medium Base Replacement Socket LSOC 150 077249 Screw-on Guard LVPG 150 077978 Replacement Lamps SCEPTALIGHT Description Part Number Product Code 7 Watt LD/E 7 072841 9 Watt LD/E 9 072844 13 Watt LD/E 13 072847 18 Watt (Quad) LD/E 18 077947 26 Watt (Quad) LD/E 26 077081 Cor-Line ENT – Savings for the Long Run Description Part Number Product Code 7/9 Watt Lamp Holder LLH 7/9 072843 13 Watt Lamp Holder LLH 13 072849 18 Watt Lamp Holder (4 Pin) LLH 18 072818 26 Watt Lamp Holder (4 Pin) LLH 26 077082 Noncorroding and nonconducting, Cor-Line Electrical Nonmetallic Tubing and fittings are designed For The Long Run. Coiled in lengths up to 1,500 feet, the Cor-Line system can span the longest run. Encased in concrete, concealed in walls or ceilings, Cor-Line offers the best alternative to the labour-intensive, 10' lengths of metal conduit with its couplings and scrap. The Cor-Line System is the right choice! Kwikon Fittings Ballasts Description Part Number Product Code 7/9 Watt Magnetic Ballast (NPF) LEB 7/9 072842 13 Watt Magnetic Ballast (NPF) LEB 13 072848 18 Watt Electronic Ballast (HPF) LEB 18 077224 26 Watt Electronic Ballast (HPF) LEB 26 077080 Our unique Kwikon couplings, transition couplings and connectors are designed with six 360° locking tabs to ensure a secure concrete-tight connection. Time-consuming taping and solvent cementing are eliminated. Gaskets Description Part Number Product Code Box Gasket LBGASK 150 072820 Lamp Gasket LLGASK 150 076971 C22.2 – No. 227.1 CORLINE ENT & KIWKON FITTINGS Replacement Lamp Holders 54 COR-LINE ® ENT & KWIKON ® FITTINGS COR-LINE ® ENT & KWIKON ® FITTINGS Ease of Installation Pulling Wire Engineered for the rugged day-to-day challenges of the construction industry, Cor-Line has already established itself as a market leader. Requiring no special tools for bending or cutting, Cor-Line is easily installed. Kwikon’s interior corrugated surface greatly reduces the amount of friction while pulling conductors through long runs, even with 90° bends. 55 CSA Certified Bending & Cutting Cor-Line’s corrugated construction allows it to be easily bent by hand, no longer requiring special bending equipment traditionally required with metal conduit systems. When bending, ensure the radius of the curve is at least six times the internal diameter of the tubing. Pre-Assembly of Kwikon Slab Boxes Pre-Assembly of Metallic Boxes FT-4 Approved IPEX Cor-Line ENT tubing meets and exceeds the requirements of CSA’s vertical char test as described in Clause 4.11.4 of CSA C22.2 No. 0.3M. Direct Burial The Canadian Electrical Code approves ENT for direct earth burial. Rules governing installation of Cor-Line ENT are covered in the CEC Part 1, Rule 12-1500 through 12-1516. Installation in Noncombustible/Combustible Construction Metallic slab boxes can be quickly preassembled with Kwikon connectors. Secured with a locknut, Kwikon connectors provide a concrete-tight connection. Refer to Section 3.1.5.19 of the National Building Code for rules governing the use of combustible conduit in noncombustible and/or combustible buildings. Where provincial codes vary, please consult with the building authority having jurisdiction. Installation in Sheer Walls, Interior Walls & Block Walls Nonmetallic Raceways for Fire Alarm System Conductors Cor-Line’s flexibility, lightweight and ease of handling in metal, wood, or block walls, combined with Kwikon connectors and couplings, substantially reduce time and labour needed to install electrical raceways. Rule 32-102 of the CEC allows Cor-Line ENT to be used for fire alarm systems in noncombustible or combustible buildings provided: (1) the raceway is embedded in at least 50mm (2 in.) of masonry or poured concrete, and (2) where electrical nonmetallic tubing (ENT) is used, the transition from ENT to metal raceways is made in the concrete using a transition fitting or other acceptable means. (Kwikon transition fittings are specifically designed for this application.) CORLINE ENT & KIWKON FITTINGS CORLINE ENT & KIWKON FITTINGS IPEX’s Kwikon slab boxes are available with or without molded connectors. For boxes without molded connectors, pre-assembly is quick and simple using our snap-in connector or threaded male adapter with locknuts. Both provide a secure concrete-tight connection. Cor-Line Electrical nonmetallic tubing and Kwikon fittings are certified to CSA C22.2 No. 227.1. COR-LINE ® ENT 56 Reel & Coil Size Size (in) 1/2 Coil Reel 3/4 57 KWIKON ® ENT FITTINGS Kwikon Coupling Length (ft) Product Code 1500 Weight lbs/pkg Size (in) Part Number Product Code Package Qty 185 1/2 KC10 089000 150 145 3/4 KC15 089001 100 KC20 089002 50 012004 1000 012009 1 750 012019 155 1 1-1/4 1000 012047 205 1-1/4 KC25 189670 30 1-1/2 750 012033 180 1-1/2 KC30 189671 30 2 500 012044 160 2 KC35 189672 20 1/2 370 012000 37 3/4 240 012008 30 1 160 012018 28 1-1/4 500 012046 102 1-1/2 300 012032 72 2 225 012043 62 Kwikon Connector For Concrete Encasement Size (in) Part Number Product Code Package Qty 1/2 KTA10 089006 150 3/4 KTA15 089007 100 1 KTA20 089008 50 1-1/4 KTA25 189680 30 Wrapped in plastic, coils are easily dispensed from the centre. Size (in) Length (ft) Product Code Weight lbs/pkg 1/2 x 10' 3600 012005 345 1-1/2 KTA30 189681 30 3/4 x 10' 2200 012006 315 2 KTA35 189682 20 1 x 10' 1800 012007 345 Cor-Line Dimensions CORLINE ENT & KIWKON FITTINGS CORLINE ENT & KIWKON FITTINGS 10' Sticks Kwikon Snap-in Connector Size (in) ID (in) OD (in) 1/2 0.574 0.840 Size (in) Part Number Product Code Package Qty 3/4 0.778 1.050 1/2 KTS10 089146 150 1 1.000 1.315 3/4 KTS15 089147 100 1-1/4 1.340 1.660 1 KTS20 089148 50 1-1/2 1.574 1.900 2 2.020 2.375 Kwikon Transition Coupling Weight Comparison of Cor-Line ENT vs EMT Size (in) ENT lbs/1000' EMT lbs/1000' 1/2 100 295 3/4 125 440 1 175 668 1-1/4 185 970 1-1/2 220 1,100 2 319 1,517 CSA C22.2 No. 227.1 Size (in) Part Number Product Code Package Qty 1/2 KTC10 089012 125 3/4 KTC15 089013 100 1 KTC20 089014 50 58 59 KWIKON ® ENT FITTINGS KWIKON ® ENT FITTINGS Kwikon 90o Stub Down Fittings Kwikon Slab Box Engineered to be rugged and durable, IPEX’s boxes will withstand construction’s harshest environments. KT90 Stub Down Fittings (Kwikon x Threaded) Size (in) Part Number Product Code Package Qty 1/2 KT90-10 089060 40 3/4 KT90-15 089059 35 1 KT90-20 089058 25 KK90 Stub Down Fittings (Kwikon x Kwikon) Size (in) Part Number Product Code Package Qty 1/2 KK90-10 089055 40 3/4 KK90-15 089056 35 1 KK90-20 089057 25 Features • Approved for use with ceiling fans up to 35 lbs. and luminaries up to 50 lbs. • Concrete tight • All molded connectors have 360° locking tabs that exceed CSA and UL requirements for pull-out • Molded connectors are also approved for use with Scepter Rigid PVC Conduit • Manufactured from high impact PVC • Nonmetallic / Nonconducting / Noncorroding • Threaded brass inserts Slab Box w/ Molded Connectors Size (in) Part Number Product Code Package Qty 1/2 KSTB-10 089330 150 Hub Size (in) Part Number Product Code Package Qty 3/4 KSTB-15 089331 150 8 x 1/2 SMB-H-10 089455 25 1 KSTB-20 089332 150 4 x 1/2, 2 x 3/4, 2 x 1 SMB-H-10/20 089456 25 1-1/4 KSTB-25 089333 150 4 x 1/2, 4 x 3/4 SMB-H-10/15 089457 25 8 x 3/4 SMB-H-15 089459 25 4 x 3/4, 4 x 1 SMB-H-15/20 089463 25 Kwikon ENT Multi-LinkTM Form Stubby Size (in) Part Number Product Code Package Qty 1/2 MSTB-10 089031 75 3/4 MSTB-15 089026 75 1 MSTB-20 089025 50 Slab Box w/o Molded Connectors Knockout Size (in) Part Number Product Code Package Qty 8 x 1/2 SMB-10 089450 25 4 x 1/2, 2 x 3/4, 2 x 1 SMB-10/20 089451 25 Kwikon ENT Angled Form Stubby Slab Box Extension Ring Size (in) Part Number Product Code Package Qty 1/2 KASTB-10 089233 50 3/4 KASTB-15 089234 50 Part Number Product Code Standard Packaging SMBR 089494 20 1 KASTB-20 089235 50 1-1/4 KASTB-25 089236 50 1-1/2 KASTB-30 089238 50 Adjusts height of SMB/SMBH series slab boxes by 1" CORLINE ENT & KIWKON FITTINGS CORLINE ENT & KIWKON FITTINGS Kwikon ENT Form Stubby Designed by contractors for contractors, Kwikon slab boxes are available in two unique styles, with or without molded connectors. Now you can provide a complete, nonmetallic slab system. Priced competitively with traditional steel mud boxes, Kwikon slab boxes increase labour efficiencies, reducing costs. 60 61 KWIKON ® ENT FITTINGS KWIKON ® ENT FITTINGS 4" Square Slab Box Hub Size (in) Part Number Product Code Package Qty 8 x 1/2 SSBH-10 089452 25 8 x 3/4 SSBH-15 089453 25 4 x 1/2 & 4 x 3/4 SSBH-10/15 089454 25 The NEW ENT Support Unit (ESU) raises the tubing or conduit up off the concrete form during the concrete pour maintaining a level raceway and allows for maximum aggregate flow and concrete consolidation. Easy to use, the ESU snaps around any size of ENT. It is perfect for use in high rise buildings constructed with post-tensioned (PT) concrete slabs. Features Shallow Slab Box Hub Size (in) Part Number 8 x 1/2 SMBS-H-10 Product Code Package Qty 089485 20 4 x 1/2 & 4 x 3/4 SMBS-H-10/15 089486 20 8 x 3/4" SMBS-H-15 089487 20 4 x 1/2, 2 x 3/4, 2 x 1 SMBS-H-10/20 089488 20 4 x 3/4 & 4 x 1 SMBS-H-15/20 089489 20 • • • • • Part Number Product Code ESU-10-35 089149 One size fits all 1/2" - 2" Saves time and labour Easy locking mechanism Securable to the concrete form Minimal footprint reduces amount of surface contact Accessories • • • • Fully assembled and installation ready Perfectly suited for deep or shallow construction preferences Concrete-tight poly film covering the box opening Kwikon hubs do not protrude inside the box Kwikon Concrete 3-1/2" Deep Concrete Wall Box ENT 4" Square Box Flat Cover Size (in) Part Number Product Code 1/2 KO KWBC-10 089500 Tapered Plugs Hub Size (in) Part Number Product Code Size (in) Part Number Product Code Package Qty 4 x 1/2, 4 x 3/4 SVDB-H-10/15 089496 1/2 TP10 089003 100 4 x 3/4, 4 x 1 SVDB-H-15/20 089049 3/4 TP15 089004 100 4 x 1/2, 2 x 3/4, 2 x 1 SVDB-H-10/20 089052 1 TP20 089005 100 8 x 3/4 SVDB-H-15 089065 Kwikon Cutter & Blades Kwikon 2" Shallow Concrete Wall Box Description Part Number Product Code Cutter (1/2"- 1") CLC20 089066 Hub Size (in) Part Number Product Code Blades for CLC20 SSB 089067 4 x 1/2 SVSB-H-10 089054 Cutter (1/2"- 2") CLC35 089068 4 x 3/4 SVSB-H-15 089053 Blades for CLC35 SB35 089069 CORLINE ENT & KIWKON FITTINGS CORLINE ENT & KIWKON FITTINGS Concrete Wall Boxes SUPER DUCT ® PIPE & FITTINGS 63 Visit our website: www.ipexelectrical.com PRODUCT INFO TECHNICAL DOCUMENTS ONLINE TRAINING & MUCH MORE ... Super Duct Pipe and Fittings Super Duct is recognized by major utilities, contractors and engineering firms as the premier ducting product available on the market. Rigid Super Duct (Type DB-2) conforms to the testing requirements of CSA Standard C22.2 No. 211.1 both for encasement in concrete/masonry and for direct burial. + DOWNLOAD OUR SCEPTER ELECTRICAL CATALOGUE OR OUR ELECTRICAL POCKET PRO CSA C22.2 No. 211.1 SUPERDUCT Super Duct is manufactured with a specialized compound and engineered for high impact and crush strength specifically required by utilities for underground duct. This compound enhances the friction coefficient of Super Duct for easier pulling of conductors/wires through long runs. 64 65 INSTALLATION ENGINEERING DATA Lightweight Field Bending Super Duct is easy to carry and install, reducing labour and costs. The natural flexibility of IPEX Super Duct allows field bending, so minor changes in elevation or direction can often be accommodated without the use of special sweeps or fittings. The following table indicates typical maximum offset bends that can be achieved by “cold bending.” Long Lengths Super Duct is available in 10' and 20' lengths, minimizing the number of connections needed. Allowable Offset for Super Duct Bell Ends Super Duct is bell-ended, allowing for easy assembly in the field. Offset High Compressive Strength Super Duct’s specially formulated compound is designed to withstand high loads. Low Coefficient of Friction Max Allowable Offset 20' Length in. mm in. mm in. mm 2 50 20 508 79 2 007 3 75 14 356 56 1 422 3-1/2 90 12 305 49 1 245 4 100 11 279 43 1 092 Quality Control 5 125 7 178 35 889 Stringent, continuous testing ensures that Super Duct is a consistently high quality product. 6 150 7 178 29 737 The smooth bore of Super Duct facilitates cable pulling and eliminates costly cable damage. CORLINE ENT & KIWKON FITTINGS Max Allowable Offset 10' Length Size NOTES: Description CSA Requirements Reference Pipe Stiffness @ 5% 43.5 psi (300 kPa) CSA C22.2 No. 211.1 Crush Resistance 198 lbs. @ 73°F (90 kg @ 23°C) CSA C22.2 No. 211.1 10% max. residual deflection Impact Resistance 45 ft. lbf @ 73°F (61J @ 23°C) CSA C22.2 No. 211.1 25 ft. lbf @ 0°F (34J @ -18°C) Residual Stress 149°F (65°C) for 4 hours. Allow to cool to 73°F (23°C). 0.5% shrinkage allowed. Joint Tightness 5 psi (35 kPa) internal water CSA C22.2 No. 211.1 pressure applied for 24 hours. Note: Super Duct meets or exceeds all CSA requirements. CSA C22.2 No. 211.1 Axial deflection should not be attempted at the joints. 2. The above values were established for ambient temperatures above the freezing point. Increased radii may be desirable at below-freezing temperatures. SUPERDUCT Super Duct (Type DB-2) 1. INSTALLATION 66 INSTALLATION Bends Concrete Encased Duct Installation Standard 90°, 45° and 22 1/2° bends are available from sizes 2" through to 6" in 24", 36", 42" and 60" radius. All bends are supplied with 6" (15.2cm) tangents. The centre line lay length (L) can be calculated using; For multipurpose power cable and communication duct banks, spacing between ducts is critical for optimum performance. IPEX has designed the Monobloc and Vertical Lok Spacer systems to accommodate all specification and field installations. L = Where: § (π r x 180 ) + 2 (tangent) These light weight spacers provide the vertical and horizontal separation required in a trench. π = 3.14 L = centre line lay length r = radius of bend § = angle of bend tangent = 6" Example: for a 3" 90° bend with a 36" radius - calculate the lay length: L = 90° (3.14 x 36 x 180° ) + 2 (6) L = 69 inches L (metres) = With spacers in place on the trench bottom, lay the first tier of ducts. When using a concrete base, lay the bottom tier before the base has taken initial set. Place subsequent tiers of spacers on top of the tier until the required number of ducts are installed. Then tie the entire assembly together. It is not necessary to weight or brace the bank unless the concrete mix is very wet. The Concrete Pour L imperial = 69" = 1.75m 12 x 3.281 67 Do not allow a heavy mass of concrete to fall directly onto the duct. If this is a possibility, use a plank to direct the concrete down the sides of the bank assembly to the trench bottom. The concrete will flow to the centre of the bank and rise up in the middle, uniformly filling all open spaces. Voids can be eliminated by carefully working a long, flat slicing bar or spatula up and down between the vertical rows of ducts. Concrete should then flow between and under all of the ducts. 39.37 Duct Bank Elevation 45° Monobloc spacers should be staggered. It is recommended that spacers be located approximately one-fifth of duct length from each end. Vertical Lok spacers should be located to a maximum of every 5.5 ft. (1.7m). 221/2° Static Friction Coefficient Ducting Materials PVC RTRC .0 .1 .2 .3 .4 .5 .6 .7 .8 Backfilling Backfill with regular excavated soil after the concrete has set. SUPERDUCT SUPERDUCT 90° INSTALLATION 68 INSTALLATION Concrete Encased Tier-by-Tier Installation Direct Burial Installation The advantage of this method is the production of a solid, void-free concrete envelope. Simply pour each tier independently. Trench Bottom Trench Bottom Cross-section of tier-by-tier method. After grading the trench, place a foundation of 3" of concrete on the bottom. It should be smooth and graded. 69 The trench bottom should provide a continuous, firm and uniform support for the duct bank construction. Care should be taken to avoid lumps, ridges, depressions and stones causing “point” contacts or uneven bearing. Rock or Shale Bank Assembly Lay the bottom tier of ducts on the concrete base. Ducts should be spaced with wooden combs (two per duct length). Concrete the first tier level to the top of the comb. Remove combs and fill the voids. Type of wood comb used. Light tamping will ensure an even surface. Repeat this sequence until the bank is built up. Excavate 3" below the desired depth and bring the trench back to grade with selected tamped soil. This will provide the duct with a uniform bedding surface. Unstable Soils Tests should be conducted to establish the soil strength in marshy or swampy areas. It may be necessary in these conditions to dig deeper and refill with crushed stone or gravel, or to employ mats, timbers or a concrete base. Concreting If the concrete is allowed to set before assembling the next tier, the concrete will be stronger and more dense and the ducts will be aligned straighter. One problem with this method is that the bank will be in a series of layers and therefore more likely to heave and separate under frost conditions. If successive tiers are laid before the concrete has set, a satisfactory bond will be achieved by tamping the dry concrete. After the first tier of ducts is installed, backfill and compact as outlined below. If wood combs are employed for spacing, remove them as the backfill is placed and tamped. Then begin the next tier. Initial Backfilling 1. Fit side and centre to the top of the ducts. Use a hand tamper only to tamp firmly. Backfilling 2. Backfill over the duct to the required thickness (see note) and tamp firmly, using only a hand tamper. Backfill with regular excavated soil when the bank is complete. 100' 100' 100' 100' 100' Duct is usually laid in 100' sections once the trench is excavated. Therefore, concreting can be a continuous process. Final Backfilling When the last tier is placed, hand-place the backfill to 4" over the duct with soil that does not contain stones larger than 3/8". Handtamping of this layer is optional, depending on the specifications. From this point, backfill may be completed by hand or by pneumatic tamping in layers from 4" to 12" depending on the degree of compaction desired. When placing backfill by machine, avoid the use of large rocks until a protective layer (minimum of 12") is established. Note: In direct burial, no spacer should be used with Type 2; spacers provide “point” support instead of the continuous bed required. Backfill thickness between ducts is usually 2" to 3". SUPERDUCT SUPERDUCT Placement of Duct 70 SUPER DUCT ® FITTINGS SUPER DUCT ® PIPE CSA Type II PVC Coupling - Solvent Weld Dimension 10' L Belled Ft/Crate (in) Product Code 2 008220 3 008230 3-1/2 008235 4 008240 5 008250 6 71 008260 2,460 1,120 810 630 430 280 20' L Belled Weight/100' Ft/Crate Product Code (lbs) 08221 08231 08236 08241 08251 08261 4,920 2,240 1,620 1,260 860 560 Dimension (in) Part Number Product Code 33.7 2 SWC020 029001 61.2 2 (long) SWC020L 029009 77.3 3 SWC030 029002 99.2 3-1/2 SWC035 029003 159.6 4 SWC040 029004 226.6 5 SWC050 029005 6 SWC060 029006 CSA Type II Split Duct Dimension (in) Product Code Ft/Crate Weight/100' (lbs) 2 008222 2,460 33.7 3 008232 1,120 61.2 3-1/2 008237 810 77.3 4 008242 630 99.2 5 008252 430 159.6 6 008262 280 226.6 Polyethylene Coupling – Push Fit Dimension (in) Part Number Product Code 2 PFC020 029011 3 PFC030 029012 3-1/2 PFC035 029013 4 PFC040 029014 5 PFC050 029015 6 PFC060 029016 Duct Diameter Minimum ID Nominal Wall Average OD 2 2.001 .082 2.250 3 3.000 .097 3.250 3-1/2 3.480 .109 3.730 4 3.941 .120 4.216 5 4.974 .153 5.299 6 5.896 .180 6.275 PVC 5° Coupling – Solvent Weld Dimension (in) Part Number Product Code 2 3 5ACS20 5ACS30 029041 029042 3-1/2 4 5 6 5ACS35 5ACS40 5ACS50 5ACS60 029043 029044 029045 029046 Super Duct Dimensions in Millimetres Duct Diameter Minimum ID Nominal Wall Average OD 50 50.83 2.08 57.15 75 76.20 2.46 82.55 Dimension (in) Part Number Product Code 90 88.39 2.77 94.74 3 5APF30 029030 100 100.10 3.05 107.09 3-1/2 5APF35 029502 125 126.34 3.89 134.60 4 5APF40 029998 150 149.76 4.57 159.39 5 5APF50 029050 Polyethylene 5° Coupling – Push Fit SUPERDUCT SUPERDUCT Super Duct Dimensions in Inches 72 SUPER DUCT ® FITTINGS 73 SUPER DUCT ® FITTINGS Expansion Joint Terminator with Knock-Out Plugs Dimension (in) Part Number Product Code Dimension (in) Part Number Product Code 2 EXPJ20 029151 3 TERM30 029826 3 EXPJ30 029152 3 1/2 TERM35 029523 3-1/2 EXPJ35 029153 4 (with holes) TERM40H 029822 4 EXPJ40 029154 4 (no holes) TERM40W 029827 Reducer Coupling – Solvent Weld Cap – Solvent Weld Dimension (in) Part Number Product Code 3x2 RC3020 029021 3-1/2 x 2 RC3520 029039 3-1/2 x 3 RC3530 029022 4x2 RC4020 029023 4x3 RC4030 029024 4 x 3-1/2 RC4035 029025 5x4 RC5040 029026 6x4 RC6040 029027 Dimension (in) Part Number Product Code 2 SWCA20 029071 3 SWCA30 029072 3-1/2 SWCA35 029073 4 SWCA40 029074 5 SWCA50 029075 6 SWCA60 029076 90° Long Sweep Bend Dimension (in) Part Number Product Code 2 x 24 R 902024 029091 Dimension (in) Part Number Product Code 2 x 36 R 902036 029092 2 SPLY20 029051 2 x 60 R 902060 029036 3 SPLY30 029052 3 x 24 R 903024 029055 3-1/2 SPLY35 029053 3 x 36 R 903036 029093 4 SPLY40 029054 3 x 60 R 903060 029134 3-1/2 x 24 R 903524 029123 3-1/2 x 36 R 903536 029094 3-1/2 x 60 R 903560 029135 4 x 24 R 904024 029047 4 x 36 R 904036 029095 4 x 60 R 904060 029096 5 x 42 R 905042 029097 5 x 60 R 905060 029037 6 x 60 R 906060 029098 PVC Bell Ends Dimension (in) Part Number Product Code 2 BELL20 029061 3 BELL30 029062 3-1/2 BELL35 029063 4 BELL40 029064 5 BELL50 029065 6 BELL60 029066 SUPERDUCT SUPERDUCT Split Wye – Solvent Weld SUPER DUCT ® FITTINGS 74 75 SUPER DUCT ® FITTINGS 45° Long Sweep Bend Universal Pipe Plug Dimension (in) Part Number Product Code Dimension (in) Part Number Product Code 2 x 24 R 452024 029111 2 & 2-1/2 UPP35 077433 2 x 36 R 452036 029112 3 & 3-1/2 UPP45 077434 3 x 24 R 453024 029082 4 UPP55 077435 3 x 36 R 453036 029113 5 UPP60 077436 3-1/2 x 36 R 453536 029114 6 UPP65 077437 4 x 24 R 454024 029128 4 x 36 R 454036 029115 4 x 60 R 454060 029116 5 x 42 R 455042 029117 6 x 60 R 456060 029118 Sleeve Female Adapter 22 1/2° Long Sweep Bend Dimension (in) Part Number Product Code 2 FEMA20 029141 3 FEMA30 029142 3-1/2 FEMA35 029143 Dimension (in) Part Number Product Code 4 FEMA40 029144 3 x 36 R 223036 029085 5 FEMA50 029145 4 x 36 R 224036 029204 6 FEMA60 029146 5 x 42 R 225042 029249 Note: Special radius bends are available upon request. Dimension (in) Part Number Product Code 2 ARIG20 029181 2 (long) ARIG20L 029188 Product Code 3 ARIG30 029182 029131 3-1/2 ARIG35 029183 029132 4 ARIG40 029184 029133 5 ARIG50 029185 6 ARIG60 029186 Tapered Plug Dimension (in) 2 3 3-1/2 Part Number PLUG20 PLUG30 PLUG35 Duct Socket 4 PLUG40 029078 5 PLUG50 029079 6 PLUG60 029136 Note: Duct to RTRC Conduit Adapters are available on request. SUPERDUCT SUPERDUCT Conduit to Duct Adapter Conduit Socket 76 Monobloc Spacer Benefits for Telephone Duct: Reducing Adapter Coupling – Duct to PVC Conduit • lightweight; easy to handle and install Dimension (in) Part Number Product Code 3x2 ARIG3020 029191 4x2 ARIG4020 029192 4x3 ARIG4030 029187 PVC Adapter Coupling – Asbestos Cement or Bituminous Fibre • weatherproof • resilient at extremely low temperatures B • flexible, yet tough • readily available in a wide range of sizes and configurations B • economical D • immune to corrosion attack C • approved by Bell Canada Dimension (in) Part Number Product Code 3-1/2 ACFB35 029163 4 ACFB40 029164 • versatile, as they can be used as both a base & intermediate spacer Selection Table (in inches) (A) Vertical Spacing (B) Horizontal Spacing (C) Ground Clearance (D) Number of Ways (E) 2 1-1/2 1-1/2 3 2 3 1-1/2 1-1/2 3 2 3-1/2 1 1 2 2-3-4 1-2-3-4 Nominal Size Vertical-Lok Spacers Intermediate Base * * * 4 1 1 2 4 1-1/2 1-1/2 3 2-3-4 4 2 2 3 1-2-3-4 2 x 1-1/2 IS3530 029550 BS3530 029566 4 3 3 3 2-3-4 2x2 IS3535 029551 BS3535 029567 4 3 3 4 2-3-4 2x3 IS3545 029552 BS3545 029568 4-1/2 2 2 3 1-2-3 3 x 1-1/2 IS4530 029553 BS4530 029569 5 1-1/2 2-1/8 3-5/8 1 3x2 IS4535 029554 BS4535 029570 5 1-1/2 1-1/2 3 2-3-4 3x3 IS4545 029555 BS4545 029571 4x1 IS5520 029556 BS5520 029572 4 x 1-1/2 IS5530 029557 BS5530 029573 4x2 IS5535 029558 BS5535 029574 4x3 IS5545 029559 BS5545 029575 5 x 1-1/2 IS6030 029560 BS6030 029576 5x2 IS6035 029561 BS6035 029577 5x3 IS6045 029562 BS6045 029578 6 x 1-1/2 IS6530 029563 BS6530 029579 6x2 IS6535 029564 BS6535 029580 6x3 IS6545 029565 BS6545 029581 8x2 IS8035 029294 BS8035 029293 * Do not have rebar slots or base holes 1 2 3 4 SUPERDUCT SUPERDUCT Dimension (in) Part Number Product Code Part Number Product Code * 77 MONOBLOC ™ SPACERS SUPER DUCT ® FITTINGS 78 SCEPTACON TM TRENCHLESS RACEWAY SYSTEMS MONOBLOC ® SPACERS 79 SUPERDUCT Monobloc Duct Spacers Description (in) A, B, C, D E Product Code Dimensional F length Drawing (in) 2 x 1-1/2 x 1-1/2 x 3 2 way 029473 2 7.9 3 x 1-1/2 x 1-1/2 x 3 2 way 029474 2 10.3 3-1/2 x 1 x 1 x 2 2 way 029860 2 12.4 3-1/2 x 1 x 1 x 2 3 way 029861 2 17.3 3-1/2 x 1 x 1 x 2 4 way 029479 2 20.9 4x1x1x2 1 way 029475 2 8.3 4x1x1x2 2 way 029476 2 13.5 4x1x1x2 3 way 029477 2 18.8 4x1x1x2 4 way 029478 2 24.2 4 x 1-1/2 x 1-1/2 x 3 2 way 029470 1 14.2 4 x 1-1/2 x 1-1/2 x 3 3 way 029471 1 20.0 4 x 1-1/2 x 1-1/2 x 3 4 way 029472 1 26.0 4x2x2x3 1 way 029480 2 8.3 4x2x2x3 2 way 029464 1 14.5 SceptaCon Trenchless Raceway Systems 4x2x2x3 3 way 029465 1 20.7 4x2x2x3 4 way 029499 1 27.0 4 x 3 x 3 x 3 (Base) 2 way 029466 3 15.0 SceptaCon is one of the first PVC systems designed for the rigors of trenchless applications. It links seamlessly to existing PVC conduit infrastructures and allows utility companies to standardize on PVC throughout their entire electrical systems. 4 x 3 x 3 x 3 (Base) 3 way 029488 3 22.5 4 x 3 x 3 x 3 (Base) 4 way 029489 3 30.0 4x3x3x4 2 way 029469 1 15.0 4x3x3x4 3 way 029497 1 22.5 4x3x3x4 4 way 029498 1 30.1 4-1/2 x 2 x 2 x 3 1 way 029485 2 8.7 4-1/2 x 2 x 2 x 3 2 way 029486 2 15.5 4-1/2 x 2 x 2 x 3 3 way 029487 2 22.2 5 x 1-1/2 x 2-1/8 x 3-5/8 1 way 029455 4 7.0 2 way 029494 2 16.2 5 x 1-1/2 x 1-1/2 x 3 3 way 029495 2 23.1 5 x 1-1/2 x 1-1/2 x 3 4 way 029496 2 30.0 SceptaCon's slide-in locking system and pre-installed, pre-lubricated gaskets allow contractors to create a water-tight seal by hand in seconds - in all temperatures - without having to worry about solvents or chemicals freezing or drying too quickly. Its unique spline-lock snaps into a recessed opening, ensuring the spline won't get snagged during pull-through. SceptaCon's rounded bell shoulders slide easily past roots, rocks and other debris in the borehole, ensuring a smooth, easy installation. And because SceptaCon is made to the same high standards as our Scepter rigid PVC conduit, contractors and electrical utilities can be assured of the same level of quality - above ground and below. SCEPTACON 5 x 1-1/2 x 1-1/2 x 3 TM 80 SCEPTACON TM TRENCHLESS RACEWAY SYSTEMS KWIKPATH ® COMMUNICATION RACEWAY SYSTEMS 81 No Cementing or Lubrication SceptaCon’s slide-in locking system and preinstalled, pre-lubricated gaskets allow contractors to create a water-tight seal by hand in seconds. Outperforms Other PVC Products SceptaCon’s unique spline-lock snaps into a recessed opening, ensuring the spline won’t get snagged during pull-through. SceptaCon’s rounded bell shoulders slide easily past roots, rocks and other debris in the borehole, ensuring a smooth, easy installation. No Fusion Required Because SceptaCon’s joints can be quickly joined by hand in seconds, crews don’t need large, expensive fusion equipment or special training to create water-tight joints. In addition, SceptaCon can be assembled one pipe length at a time, then pulled underground, eliminating the need for long strings of pipe on the job. Kwikpath® Optical Fibre & Communication Cable Raceway Systems Superior Performance SceptaCon is made from durable schedule 40 PVC that’s resistant to creasing, scoring or flattening when pulled past obstructions in the borehole, yet flexible enough to bend with underground twists and turns. SceptaCon remains round, unlike HDPE which can stretch and become oval. Easy to Handle SceptaCon is available in convenient 10' and 20' lengths that are light-weight, easy to handle and no problem to work with in all types of weather. SCEPTACON SceptaConTM Raceway Length Product Code 3" x 10' 106330 Kwikpath comes together faster and easier than other raceway systems, thanks largely to a patented "snap-on" design that ensures fittings and raceway assemble and terminate easily with no special tools or handling equipment needed. The six locking tabs keep the fitting tightly connected with tremendous pull-out resistance. All without messy cementing or screws to tighten. With its handy coil lengths delivered in dual purpose protective packaging/pull box, Kwikpath makes home-run systems easy and economical, letting you run cable from your telecommunications box directly to a workstation outlet with fewer couplings. Being able to cut to length on the job site ensures that you don't run short or have wasted conduit left over. Whether in narrow shafts or tight plenums, its lightweight and fast, trouble-free installation make Kwikpath the number one choice for commercial and residential cable management. 106331 Codes & Standards 4" x 10' 106340 • EIA/TIA 4" x 20' 106341 • CEC 2002/NBC 5" x 10' 106350 • NFPA 5" x 20' 106351 • Plenum FT6 6" x 10' 106360 • Riser FT4 6" x 20' 106361 • General Purpose FT1 KWIKPATH 3" x 20' 82 KWIKPATH ® COMMUNICATION RACEWAY SYSTEMS Compliance to Building Regulations Kwikpath meets all building regulations and is the only fully approved raceway and fitting combination on the market. 83 Kwikpath Plenum Raceway NBC CEC A Fitting Choice The Kwikpath fitting system reduces the need for pulling long runs of raceway around awkward corners and tight spaces. And the industry first Y-Coupler reduces the number of pull boxes required in your system design. Installation Friendly Packaging 200' coils are packaged individually in corrugated boxed cartons for ease of handling and dispensing. Designed into the cartons are packaging features that assist with moving and dispensing the product. By using the dispensing method, only the necessary product amount is withdrawn from the carton with the balance being contained and easily managed. Reduces Costs Now and Over Long Term Kwikpath is designed to allow easier cable installation and removal than other careway systems. Simply pull cables through the raceway – no more fishing new cables blindly through walls or ceilings. Kwikpath also reduces renovation costs by eliminating the need to remove existing cabling in retrofit applications. Protects Cable Integrity and Performance Kwikpath prevents cables from being damaged on edges or snags as they’re pulled through the raceway. Once cables are installed, Kwikpath offers flame resisting properties and its protective shell prevents damage to cables when renovations cause tradesmen to enter or change the walls or ceilings. Kwikpath Plenum is made from a UL approved compound and like Kwikpath Riser, forms nonmetallic, flexible corrugated cable raceways. Vibrant orange in colour, Kwikpath Plenum meets the UL tests on flame propagation and smoke density with values well below the standard requirements. This heat/smoke-resistance makes it an ideal raceway to run Optical Fiber Cables (OFPN) and/or Communication Cables (CMP/CMP-OF) through plenums and other spaces used for environmental air. Kwikpath Plenum comes with sequential markers every foot. Plenum Coil with Pull Tape Size Length Part Number Product Code 3/4" 200' KPP075TC 124020 1" 200' KPP100TC 124011 1-1/4" 200' KPP125TC 124012 1-1/2" 200' KPP150TC 124013 2" 200' KPP200TC 124014 Also available without pull tape - minimum quantity required. Plenum Reel with Pull Tape Size Length Part Number Product Code 3/4" 1000' KPP075TR 124021 1" 1000' KPP100TR 124015 1" 2500' KPP100TR48 124022 1" 5000' KPP100TR72 124023 1-1/4" 1000' KPP125TR 124016 1-1/4" 4000' KPP125TR72 124024 1-1/2" 750' KPP150TR 124017 2" 500' KPP200TR 124018 Also available without pull tape - minimum quantity required. KWIKPATH KWIKPATH KWIKPATH ® COMMUNICATION RACEWAY SYSTEMS 84 KWIKPATH ® COMMUNICATION RACEWAY SYSTEMS KWIKPATH ® COMMUNICATION RACEWAY SYSTEMS Kwikpath Plenum Fittings Kwikpath Riser Raceway Kwikpath Plenum fittings are molded from approved material to be used with Kwikpath Plenum raceway meeting all Standards requirements. The backbone of the structured cabling syste, Kwikpath Riser is a nonmetallic, flexible PVC corrugated product manufactured and tested specifically for riser applications. Easily identified by its mandarin orange color, it’s available in convenient coil or reel packaging with squential markers every foot. Plenum Coupling Size Part Number Product Code 3/4" KPPC075 132650 Riser Coil with Pull Tape 1" KPPC100 132651 Size Length Part Number Product Code 1-1/4" KPPC125 132652 3/4" 200' KPR075TC 125026 1-1/2" KPPC150 132653 1" 200' KPR100TC 125011 2" KPPC200 132654 1-1/4" 200' KPR125TC 125012 1-1/2" 200' KPR150TC 125013 2" 200' KPR200TC 125014 Plenum Terminal Adapter c/w Lockout Size Part Number Product Code 3/4" KPTA075 132660 1" KPTA100 132661 1-1/4" KPTA125 132662 1-1/2" KPTA150 132663 2" KPTA200 132664 85 Also available without pull tape - minimum quantity required. Riser Reel with Pull Tape Size Length Part Number Product Code 3/4" 1000' KPR075TR 124027 1" 1000' KPR100TR 125015 1" 2500' KPR100TR48 125023 1" 5000' KPR100TR72 125025 1-1/4" 1000' KPR125TR 125016 1-1/4" 4000' KPR125TR72 125024 1-1/2" 750' KPR150TR 125017 2" 500' KPR200TR 125018 KWIKPATH KWIKPATH Also available without pull tape - minimum quantity required. 86 KWIKPATH ® COMMUNICATION RACEWAY SYSTEMS KWIKPATH ® COMMUNICATION RACEWAY SYSTEMS Kwikpath Riser Fittings Kwikpath Resi Raceway Made from the same material as Kwikpath Riser Raceway. Kwikpath Resi is a flexible raceway system created especially for residential communications systems, arranging and organizing telephone, ethernet, satellite, internet, video, security and sound cabling. 87 Riser Coupling Resi Coil Empty Size 3/4" 1" Part Number KPRC075 KPRC100 Product Code 132655 132656 1-1/4" KPRC125 132657 1-1/2" KPRC150 132658 2" KPRC200 132659 Size Length Part Number Product Code 3/4" 200' KPH075C 127001 1" 200' KPH100C 127002 1-1/4" 200' KPH125C 127003 1-1/2" 200' KPH150C 127004 2" 200' KPH200C 127005 Resi Reel Empty Riser Terminal Adapter c/w Lockout Size Part Number Product Code 3/4" KRTA075 132665 1" KRTA100 132666 1-1/4" KRTA125 132667 1-1/2" KRTA150 132668 2" KRTA200 132669 Size Length Part Number Product Code 3/4" 1000' KPH075R 127006 1" 1000' KPH100R 127007 1-1/4" 1000' KPH125R 127008 1-1/2" 750' KPH150R 127009 2" 500' KPH200R 127010 Kwikpath Resi Fittings Kwikpath Resi couplings and terminal adapters are available in 3/4" to 2" sizes and are also Kwikpath Riser fittings. KWIKPATH KWIKPATH Refer to Kwikpath Riser Part Numbers. 88 KWIKPATH ® COMMUNICATION RACEWAY SYSTEMS Kwikpath Y-Coupler The Y-Coupler is a fitting designed to allow contractors to branch off from any size (3/4" to 2") – new or existing – corrugated communication raceway. Manufactured in traditional Kwikpath vibrant orange, the Y-Coupler is ideal for use in high-rise residential and commercial building applications. Size Part Number Product Code 3/4" to 2" KPPY075-200 132011 Seal End Plugs For temporary and long-term closure of raceway ends, the insertion of sealing end plugs ensures the raceway conduit remains clean and ready for future needs. Size Part Number Product Code 3/4" SEP075 132000 1" SEP100 132001 1-1/4" SEP125 132002 1-1/2" SEP150 132003 2" SEP200 132004 Riser / Resi Straps KWIKPATH Manufactured of the same material as Riser/RESI raceway, Kwikpath pipe straps allow for compliance with installation requirements providing for the proper support of Riser/RESI raceways. Size Part Number Product Code 3/4" KPS075 132006 1" KPS100 132007 1-1/4" KPS125 132008 1-1/2" KPS150 132009 2" KPS200 132010 Register your Pocket Pro today! Fax this form to (905) 403-1124 and we’ll add you to our mailing list. Toll Free: (866) 473-9462 IPEX 2441 Royal Windsor Drive Mississauga, Ontario L5J 4C7 Fax: (905) 403-1124 Website: www.ipexelectrical.com PLEASE PRINT Company Name Title Address City Province Postal Code Phone ext. Fax Email / Website This is a: ❏ Home Address ❏ Business Address ❏ Jobsite Address Business Type: (check 1 or 2 that best apply) Company classification: ❏ Distributor/Wholesaler ❏ Engineering Firm ❏ Contractor ❏ Government ❏ OEM - Products manufactured: ❏ Other SIC or industry sector: My primary markets are (check all that apply): ❏ Commercial ❏ Residential ❏ Industrial ❏ Other ❏ Utility ❏ OEM ❏ Institutional CUSTOMER SERVICE CENTRES Vancouver Winnipeg Saint John Tel (604) 534-8631 Fax (604) 534-7616 Tel (204) 633-3111 Fax (204) 633-3075 Calgary Toronto Tel (506) 633-7473 (PIPE) Fax (506) 633-8720 Tel (403) 236-8333 Fax (403) 279-8443 Tel (905) 670-7676 Fax (905) 670-5295 Edmonton Montreal Tel (780) 415-5300 Fax (780) 415-5358 Tel (514) 337-2624 Fax (514) 337-7886 St. John’s Tel (709) 747-7473 (PIPE) Fax (709) 368-9111 Toll Free 1-866-473-9462 (IPEXINC) About the IPEX Group of Companies As leading suppliers of thermoplastic piping systems, the IPEX Group of Companies provides our customers with some of the world’s largest and most comprehensive product lines. All IPEX products are backed by more than 50 years of experience. With state-of-the-art manufacturing facilities and distribution centers across North America, we have established a reputation for product innovation, quality, end-user focus and performance. Markets served by IPEX group products are: • Electrical systems • Telecommunications and utility piping systems • PVC, PVCO, CPVC, PP, ABS, PEX, FR-PVDF & PE pipe & ftgs (1/4" to 48") • Industrial process piping systems • Municipal pressure and gravity piping systems • Plumbing and mechanical piping systems • PE Electrofusion systems for gas and water • Industrial, plumbing and electrical cements • Irrigation systems Products are manufactured by IPEX Electrical Inc. Cor-Line®, FiberTel®, Kwikon®, Kwikpath®, Monobloc®, SceptaConTM, SceptalightTM and SuperDuct® are trademarks of IPEX Branding Inc. w w w . i p e x e l e c t r i c a l . c o m This literature is published in good faith and is believed to be reliable. However, it does not represent and/or warrant in any manner the information and suggestions contained in this brochure. Data presented is the result of laboratory tests and field experience. A policy of ongoing product improvement is maintained. This may result in modifications of features and/or specifications without notice. CTELNAIP090805 © 2010 IPEX EL004C
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.7 Linearized : No Page Count : 49 Create Date : 2014:09:03 17:39:45 Creator : Google Producer : GoogleEXIF Metadata provided by EXIF.tools