Meter Mounting Equipment
Western Region Area

MILBANK OVERVIEW

1
MILBANK OVERVIEW

Charles A. Milbank
1879-1966

Bill Martin
1916-1998

Robert F. Waldrop
1922-2002

Robert F. Waldrop, II
Chairman

Katrina Waldrop Henke
Vice Chairman

Milbank–Quality Metering Products for 80 Years

M

ilbank Manufacturing
Company was established in 1927 by
Charles A. Milbank.
Originally,
the
company
manufactured high voltage
switches; however, by 1941
Milbank devoted itself primarily
to the manufacture of sheet metal
enclosures and related equipment
for the electrical generation and
distribution industry. Today we
are an industry leader in the
manufacture of electrical meter
sockets. Through a national
network of manufacturer ’s
representatives we provide
wholesale electrical distributors
with quality electrical products
for the utility, contractor,
industrial and OEM markets.
As the meter standards have
changed, Milbank has been
successful in adapting its product
line to these changes. Our full
scale engineering department
designs products to meet
customer specifications and
satisfy all utility requirements.
Milbank’s employee base of over
1,000 workers, along with our

five manufacturing facilities
comprising almost 550,000
square feet give us the flexibility
to schedule, produce, and ship
orders quickly.
Currently,
Milbank manufactures over
10,000 different catalog items,
and this list continues to grow.
Our unique product offering
includes:
Residential
&
Commercial Meter Sockets;
Residential & Commercial Meter
Pedestals; RV/MH Power Outlets,
Service
Pedestals,
and
Transformers; Commercial &
Industrial Electrical Enclosures;
Circuit Breakers; Disconnects &
Safety Switches; Safety Sockets;
Utility & Residential Secondary
Pedestals; Hubs, and related
accessories. If you don’t find a
unit in this catalog to service your
needs, send us your specifications
and we will be happy to work
with you.
Our success has come from a
loyal customer base that can rely
on us to build quality products at
a fair price in a timely manner.
Our willingness and ability to
design and produce new products

1

to meet our customer demands is
an important factor to remain
competitive in today’s electrical
market.
Milbank has been serving the
electric utility & wholesale
distribution industries for 80 years
with innovative, quality
engineered products. So
remember us for all of your meter
mounting
and
related
requirements, and we will be
happy to serve you as we have in
the past – with dependable
service and quality products!
We take great pride in being
one of the few family-owned
businesses left in our industry.
We are a third generation run
business and truly believe that...

FAMILY MAKES A
DIFFERENCE!

PRODUCT INDEX BY CATEGORY

2

PRODUCT INDEX BY CATEGORY

AC DISCONNECTS

SECTION A

30 & 60 Amp – Fusible/Non-Fusible Air Conditioner Disconnects....................................................................................1
Combination AC Disconnect / 20 Amp GFCI Receptacle..................................................................................................2
Hot Tub Disconnect or Sub Panel Breaker Enclosure – Type 3R .......................................................................................2

METER SOCKETS

SECTION B

SINGLE POSITION (NO BYPASS)
30-100 Amp – Economy Cast Socket – Ring Type, 4T.......................................................................................................1
125-200 Amp, Ringless, 4T, 5T & 7T.............................................................................................................................2-3
125-200 Amp, Ring Type, 4T & 7T................................................................................................................................2,4
125-200 Amp, Ring Type with Manual Circuit Closing Blocks, 4T & 7T ...........................................................................9
200 Amp, Ring Type, Flush Mount, 4T .............................................................................................................................5
320 Amp, Ringless (Non-Lever Bypass), 4T.....................................................................................................................10
SINGLE POSITION (WITH BYPASS)
125-200 Amp, Ringless (Non-Jaw Clamping Lever Bypass), 4T, 5T & 7T .......................................................................6-7
200 Amp, Ringless (Jaw Clamping Lever Bypass), 4T, 5T & 7T .........................................................................................8
320 Amp, Ringless (Lever Bypass), 4T.............................................................................................................................10
320 Amp, Ring Type (Link Bypass), 4T ...........................................................................................................................11
320 Amp, Ringless (Lever Bypass), Side Wireway, 7T .....................................................................................................11
MULTIPLE POSITION
100-125 Amp, Ringless/Ring Type Horizontal Gang Sockets, 4T ....................................................................................12
200 Amp, Ringless/Ring Type Horizontal Gang Sockets, 4T ...........................................................................................13
125-200 Amp, Condominium Metering Banks, Ringless ............................................................................................15-16

METER MAINS AND SERVICE ENTRANCE EQUIPMENT

SECTION C

100/150/200 Amp, Ringless/Ring Type Meter Main, 4T & 5T – 22K AIC...........................................................................2
200 Amp, Ring Type, 4T & 7T ..........................................................................................................................................1
200 Amp, Unmetered, Service Entrance Main Breaker, 4T ...............................................................................................3
400 Amp, 320 Amp Continuous, Ringless Meter Main with Split Load, 4T .......................................................................4
400 Amp, 320 Amp Continuous, Ring Type Meter Main with Split Load, 4T ....................................................................5
400 Amp, 320 Amp Continuous, Ring Type Plug-In Socket – Meter Main with Split Load, 4T ..........................................6
400 Amp, 320 Amp Continuous, Ring Type Meter Main Combination, 4T ....................................................................7-8

COMMERCIAL METERING –
SAFETY SOCKETS, METER MAINS, TERMINATION BOXES, BUSSED GUTTERS

SECTION D

SAFETY SOCKETS
100/200 Amp – TB Series – 600 Volt Self-Contained / Socket Only, 4T, 5T & 7T..............................................................1
100 Amp, MTB Series – 10K AIC – 240 Volt Self-Contained Meter Main / CB, 4T, 5T & 7T..............................................2
100 Amp, MTB Series – 22K AIC – 240 Volt Self-Contained Meter Main / CB, 4T & 7T....................................................3
100 Amp, MTB Series – 14K AIC – 480 Volt Self-Contained Meter Main / CB, 4T, 5T & 7T..............................................4
100 Amp, MTB-P & MTB-P48 Series – 200K AIC – 240 & 480 Volt Self-Contained Meter Main /
T-Fuse Pullout, 4T, 5T & 7T.........................................................................................................................................5
200 Amp, MTB Series – 10K AIC – 240 Volt Self-Contained Meter Main / CB, 4T, 5T & 7T..............................................6
200 Amp, MTB Series – 22K AIC – 240 Volt Self-Contained Meter Main / CB, 4T & 7T....................................................7
200 Amp, MTB Series – 35K AIC – 480 Volt Self-Contained Meter Main / CB, 4T & 7T....................................................8
200 Amp, Test Block Bypass – MTB-P & MTB-P48 Series – 200K AIC – 240/480 Volt Self-Contained Meter Main /
T-Fuse Pullout, 4T, 5T & 7T.........................................................................................................................................9
100 & 200 Amp, MTBL All-In-One Series, 10K & 200K AIC – 240 Volt Meter Main – Circuit Breaker /
T-Fuse Pullout ................................................................................................................................................................10
Safety Socket Replacement Circuit Breakers & Pullouts .............................................................................................14-15
Safety Socket & T-Fuse Replacement Parts ......................................................................................................................16
UNDERGROUND TERMINATION BOXES & BUSSED GUTTERS
Underground Termination Boxes – 600 VAC..................................................................................................................11
Bussed Gutters – Type 3R - 3Ø4W – 600 VAC ...............................................................................................................12
Bussed Gutters – Type 3R - 3Ø4W – 600 VAC ...............................................................................................................13

COMMERCIAL METER PEDESTALS

SECTION E

Commercial Meter Pedestals Overview ............................................................................................................................1
Applications & Accessories...............................................................................................................................................2
Catalog Number Logic......................................................................................................................................................3
ML Series – Main Load Center ..........................................................................................................................................4
SL Series – Switched Load Center .....................................................................................................................................5
400 Amp Series ................................................................................................................................................................6
IR Series – Irrigation Control .............................................................................................................................................7
BBS/UPS Series .................................................................................................................................................................8

2

PRODUCT INDEX BY CATEGORY

CT CABINETS, TEST SWITCHES, POLYPHASE ENCLOSURES

SECTION F

Current Transformer Cabinets – Type 3R – Door Mount CT Rated Socket .........................................................................1
Current Transformer Cabinets ...........................................................................................................................................2
Current Transformer Cabinets – Mounting Racks ..............................................................................................................3
Metered Transformer Cabinets – Overhead & Underground .............................................................................................4
20 Amp – 4, 5, 6, 7, 8 & 13 Terminal Current Transformer Rated – Ringless/Ring Type ....................................................5
20 Amp – 600 VAC – 5, 6, 8, 13 & 15 Terminal Current Transformer – Test Switch Provision ..........................................6
Milbank Test Switches – 4, 7 & 10 Pole............................................................................................................................7
Test Switches – 4, 7 & 10 Pole – 600 VAC – Per ANSI C12.9 Standard.............................................................................8
Milbank Test Switch Worksheet........................................................................................................................................9

SERVICE PEDESTALS

SECTION G

125 Amp – Mobile Home Metered Pedestal – Hardwired – 120/240VAC .........................................................................1
200 Amp – Mobile Home Metered Pedestal – Hardwired – 120/240VAC .........................................................................2
100/200 Amp – Load Center Power Pedestals – All Purpose & RV Applications ...............................................................3
200 Amp Series U5240 & U5241 Ring Type Metered Pedestals ....................................................................................4-5
200 Amp Series U5136 & 5137 Ringless Metered Pedestals ..........................................................................................6-7
U5706 & U5707 Temp to Final Service Pedestal – Ringless/Ring Type ..........................................................................8-9
Mobile Home Rebuild Kits ........................................................................................................................................10-11

RV

SECTION H
Series U5000 – Unmetered – Surface Mount Power Outlet ...........................................................................................1-2
Series U5100 – Metered – Surface Mount Power Outlet ................................................................................................3-4
Series U5200 – Unmetered – Pedestal Power Outlet .....................................................................................................5-6
Series U5300 – Metered – Pedestal Power Outlet ..........................................................................................................7-8
Millennium Features....................................................................................................................................................9-10
600/1200 Amp – Pad Mounted Panel Board...................................................................................................................11
100, 200 & 400 Amp – Terminal Box .............................................................................................................................12
Lighting Accessories .......................................................................................................................................................13
Telecommunications and Pedestal Accessories...............................................................................................................14
Pedestal Mounting Accessories.......................................................................................................................................15
Metering & Single Receptacle Accessories ......................................................................................................................16
RV Replacement Parts & Accessories.........................................................................................................................17-18
RV Product Information – Wiring Diagram Label – Warranty.........................................................................................19

TEMPORARY POWER

SECTION I

U4908/U4909 Underground Service Power Outlet – Ringless/Ring Type ......................................................................1-2
Series U5000 – Unmetered – Surface Mount Power Outlet ...........................................................................................3-4
Series U5001 – Unmetered – Surface Mount Power Outlet...............................................................................................5
Series U5100 & U5101 Overhead – Ringless/Ring Type – Metered – Surface Mount Power Outlet ...............................6-7
Replacement Parts for MPAP/MPRV/HP Pedestals ............................................................................................................8

TRANSFORMERS

SECTION J

Galvanized Steel Distribution Transformer – 1∅...............................................................................................................1

MISCELLANEOUS

SECTION K

Accessories....................................................................................................................................................................1,2
UQFP Plug-In Series Circuit Breakers ...............................................................................................................................3
UQFB Bolt-On Series Circuit Breakers ..............................................................................................................................4
Conduit, Ampacity, SCCR Information..............................................................................................................................5
Energization of Electrical Equipment.................................................................................................................................6
Materials and Finishes ......................................................................................................................................................7
Meter Forms .....................................................................................................................................................................8
Watthour Meter Forms – Standard Forms, Transformer Rated or Self-Contained ...............................................................9
Standard NEMA Configurations ......................................................................................................................................10
Additional Milbank Products ..........................................................................................................................................11

ALPHA-NUMERIC INDEX

SECTION L

Alpha-Numeric Index ....................................................................................................................................................1-2

3

PRODUCT INDEX BY CATEGORY

Power Transfer Series – Metered & Unmetered .................................................................................................................9
General Specifications ....................................................................................................................................................10
Commercial Meter Pedestal Drawings – 16” Metered & Unmetered ...............................................................................11
Commercial Meter Pedestal Drawings – 24” Metered & Unmetered ...............................................................................12
Commercial Meter Pedestal Drawings – 32” Metered .....................................................................................................13
Commercial Meter Pedestal Drawings – Metered ...........................................................................................................14

3

CATALOG NUMBER LOGIC

CATALOG NUMBER LOGIC

4

4

30 & 60 AMP–FUSIBLE / NON-FUSIBLE–AIR CONDITIONER DISCONNECTS

A1
SECTION A
AC DISCONNECTS

U3801

U3800

U3860

(No deadfront required)

PROFILE
Milbankʼs air conditioner disconnect has a removable hinged cover which makes wiring a breeze. Our
compact design meets all wire bending space requirements in the NEC and, also, complies with article
440-14 in the NEC. To insure the safest conditions, we designed our disconnect pullers to be
removable or they may be reinstalled in the off position. Another safety feature is the padlock provision
on the front cover. As with all Milbank products, our enclosure is constructed of G90U galvanized steel
and finished with an attractive, light gray, baked powder coating. Our state of the art finish combines
epoxy and polyester hybrid resins into a hybrid powder coating which is then electrostatically applied.
This offers a durable, nonfading finish.

TECHNICAL INFORMATION
AMP

TYPE

CATALOG
NUMBER

MAX WT.
H.P. @
#

30

FUSIBLE

U3830

3

2.7

60

FUSIBLE

U3860

10

3.3

60 NONFUSIBLE

U3800

10

3.25

60 NONFUSIBLE

U3801

10

2.5

LINE & LOAD
WIRE RANGE

GROUND
WIRE RANGE

DIMENSIONS

WIRE RATING
CU °C

CU

AL

CU/AL

D"

W"

H"

#14-#3
AWG
#14-#3
AWG
#14-#2
AWG
#14-#3
AWG

#14-#3
AWG
#14-#3
AWG
#12-#2
AWG
#14-#3
AWG

#14-3 AWG

2-5/8

5

7

#14-3 AWG

3

5

#14-3 AWG

3

5

#14-3 AWG

2-3/8

5

AL °C

60°/75° 60°/75°

91⁄4 60°/75° 60°/75°
8

60°/75° 60°/75°

6-3/4 60°/75° 60°/75°



U/L listed as Enclosed Pullout Switch



Type 3R Rainproof



1∅, 240 VAC



Six one-inch concentric knockouts

Utility requirements for this equipment may vary. Always consult the serving utility for their requirements before ordering or
installing equipment in this catalog.

A1

AC DISCONNECT / SPA BOX

Combination AC Disconnect / 20 Amp GFCI Receptacle–Together in 1 Box

SECTION A

A2

• Meets NEC # 210.63 Requirements *
• UL Listed as Power Outlet
• Type 3R Enclosure
• In-Use Cover**
• Duplex Ground Connector
• 1” Concentric Knockouts
*

AC DISCONNECTS

60 amp,
Non-Fused
AC Disconnect

AC DISCONNECT
• 1∅, 240 Volt
• 60 amp, Non-Fused

Duplex 20 amp
GFCI Receptacle
Type 3R
Enclosure with
In-Use Cover

GFCI RECEPTACLE
• 20 amp
• Reset/Test Button
• Padlock provision

U3822-20GR

AMP
60

TYPE

CATALOG MAX WT.
NUMBER H.P. #

NONFUSIBLE U3822-20GR

10

LINE & LOAD CONNECTOR
WIRE RANGE

6

NEC® #210.63 Heating, AirConditioning and Refrigeration
Equipment Outlet.
...The receptacle shall be
located on the same level and
within 7.5 m (25 ft.) of the
heating, air-conditioning and
refrigeration equipment.
* NEC® #210.08 Ground-Fault
Circuit– Interruptor protection
for personnel.

GROUND CONNECTOR
WIRE RANGE

DIMENSIONS

WIRE RATING
CU °C

W"

H"

AL °C

CU

AL

CU/AL

D"

#14-#2

#12-#2

#14-4

4.8 5.25 7.4 60°/75° 60°/75°

To ensure the safest conditions, Milbank disconnect pullers are designed to be reversible so they may be reinstalled in the OFF position.
All units are designed with a padlock provision on the cover for security.
**Note: U3822-20GR cover rated as IN-USE COVER (Cover may be closed with cords plugged into receptacle).
*Reprinted with permission from NFPA 70-2002, National Electrical Code®, Copyright 2001, National Fire Protection Association, Quincy, MA 02269. This reprinted material is not the complete
and official position of the NFPA on the referenced subject, which is represented only by the standard in its entirety. National Electrical Code® and NEC® are registered trademarks of the
National Fire Protection Association, Quincy, MA.

Hot Tub Disconnect or Sub Panel Breaker Enclosure–Type 3R
Spa Box with GFCI Protection
•
•
•
•
•
•
•
•
•
•
•

240 volt ground fault protection
UL listed, Type 3R rainproof
Milbank reliability
Easy installation
2 pole, 50 amp GFCI breaker protection
Compact size:
8-1/2” H x 7-1/2” W x 3-3/4” D
3 or 4 wire installation
1∅, 120 / 240 VAC
Standard package of 12
2 extra one-pole breaker spaces
100 amp overall rating

Sub Panel Breaker Enclosure
• Use as a 100 amp, 4 circuit sub panel
enclosure
U4881-O-50GB

AMP TYPE

CATALOG
NUMBER

WT.
#

LINE & LOAD CONNECTOR
WIRE RANGE

GROUND CONNECTOR
WIRE RANGE

DIMENSIONS

CU

AL

CU/AL

D"

W"

H"

50 BREAKER U4881-O-50GB

8

#14-1/0

#14-1/0

#14-1/0

3 3⁄4

71⁄2

81⁄2

60 BREAKER U4881-O-60GB

8

#14-1/0

#14-1/0

#14-1/0

3 3⁄4

71⁄2

81⁄2

A2

30/60/100 AMP—4 TERMINAL—ECONOMY CAST SOCKET—RING TYPE

B1

ECONOMY SOCKET





Temporary Service
Outdoor Advertising
Small Customer Service
Other Low Amperage Requirements

SECTION B

100 amp max rated is ideal for use on:

METER SOCKETS

FOR USE WITH SINGLE PHASE
SELF-CONTAINED 4 TERMINAL METERS

Our enclosure is made of die cast aluminum. The electrostatically applied epoxy and
polyester resins, which are baked on, form a durable, light gray exterior. The current carrying
parts are of copper alloy. The ground connector is designed to insure a positive electrical
connection by effectively clamping the conductor against a serrated surface.

30-100 AMP—4 TERMINAL—ECONOMY CAST SOCKET—RING TYPE
SERVICE

CATALOG
NUMBER

HUB
SIZE

CONNECTOR
CU/AL

QUANTITY
PER PACKAGE

CONCENTRIC
KNOCKOUTS

OH/UG

AP2300-03

1"

#12-#1

12

3/4", 1"

OH/UG

AP2300-04

11⁄4"

#12-#1

12

3/4", 1"

FIFTH & SIXTH TERMINAL: Contact factory.
SEALING RING: Supplied with a snap action sealing ring.
HUB: Units supplied with cast in hub on top and bottom. Consult factory for availability of other hub sizes.
BYPASS: Also available with auto bypass. Contact factory.

Utility requirements for this equipment may vary. Always consult the serving utility for their requirements before ordering or
installing equipment in this catalog.

B1

125 AMP—4 & 7 TERMINAL—SINGLE POSITION—RINGLESS / RING TYPE—600 VAC

SECTION B

B2

1

2
7490

4 3 4
METER SOCKETS

5

1

2

4 3 4
5

6

6

7487
6

1

U7487-RL

2

U7490-O

1681

3

5

6

125 AMP–SINGLE POSITION–4 TERMINAL–RINGLESS
AMP
125
125

SERVICE
UG
OH/UG

CATALOG
NUMBER

HUB

U7487-O

BLANK

U7487-RL

H.O.

CONNECTORS
CU/AL
#6-2/0
#6-2/0

DIMENSIONS
D"

W"

5

8

⁄16

3

5

⁄16

3

8

CONCENTRIC K.O.ʼS

H"
11

1

11

1

⁄2
⁄2

1

2

3

4

5

1

11⁄2

2

11⁄4

1

1

—
—

1
1

⁄2
⁄2

1

⁄2

2

11⁄4

6
1

⁄4

1

⁄4

125 AMP–SINGLE POSITION–4 TERMINAL–RING TYPE
AMP
125
125

SERVICE
OH/UG
UG

CATALOG
NUMBER
U7490-RL
U7490-O

HUB
H.O.
BLANK

CONNECTORS
CU/AL
#6-2/0
#6-2/0

DIMENSIONS
D"
5

⁄16

3

5

⁄16

3

W"
8
8

CONCENTRIC K.O.ʼS

H"

1

11

1

1

11⁄2

11

1

1

1

⁄2
⁄2

1
1

⁄2
⁄2

2

1

⁄2

3

4

2

11⁄4

2

1

1

⁄4

5

—
—

6
1

⁄4

1

⁄4

125 AMP–7 TERMINAL–RING TYPE
AMP
125

SERVICE
OH

CATALOG
NUMBER

HUB

U1681-RL

H.O.

CONNECTORS
CU/AL
#6-2/0

DIMENSIONS
D"

W"

7

10

4

⁄8

CONCENTRIC K.O.ʼS

H"
18

1

⁄2

1

2

3

4

5

2

2

2

—

1 1
4, 2

⁄ ⁄

6
3

⁄4

FIFTH TERMINAL: For field mounted fifth terminal on the U7487 & U7490 order catalog number 5T8K2 to fit into round
opening at the 9 oʼclock position.
HUBS: For proper hub selection see the hub suffix chart on the accessory page.
CONNECTORS: Extruded aluminum connectors are tin plated.
SEALING RINGS: Ring type units supplied with an MR-2 snap action sealing ring as standard.

Utility requirements for this equipment may vary. Always consult the serving utility for their requirements before ordering or
installing equipment in this catalog.

B2

200 AMP—4 TERMINAL—SINGLE POSITION—RINGLESS—600 VAC

B3

SECTION B
METER SOCKETS

U7040-XL-TG

1

2

4 3 4
5

U1060-RL

1

1

2

2

7040
1060
7021

6

5

3

6

3

1980

5

4

6

200 AMP–SINGLE POSITION–4 TERMINAL–RINGLESS
AMP
200
200

SERVICE
OH
UG

CATALOG
NUMBER
U1060-RL
U1527-O

HUB
H.O.
BLANK

CONNECTORS
CU/AL
#2-350
#2-350

DIMENSIONS
D"
1

4

⁄8

1

4

⁄8

W"
8
11

CONCENTRIC K.O.ʼS

H"

1

15

1

15

1

2
2

⁄2
⁄2

2

2

1

1

2

1

2

13

15

1

1

8

15

1

2
2

UG

U1980-O

BLANK

#6-350

4

200

OH

U7021-RL-TG

H.O.

#6-350

4

⁄2
⁄8

⁄4
⁄2

1

11

15

1

7

13

15

1

200

OH/UG

U7040-XL-TG

C.P.

#6-350

4

200

OH/UG

U7043-XL-TG

C.P.

#6-350

4

⁄8
⁄8

⁄2
⁄2

2

2

1

200

2

⁄2
⁄2

1

1

2

1

2

⁄2
⁄2

⁄2
⁄2

1

⁄2

1

⁄2

3

4

—

⁄2

1 1
4, 2

1

1

—

2

1

⁄ ⁄

3

1

1

⁄2

2

1

—

1

1

1

2
2

⁄2
⁄2

3

2

6
1

2

2

5

⁄2

3

⁄2

⁄4

1 1
4, 2

⁄ ⁄
1

⁄4

⁄4
⁄4

1 1
4, 2

⁄ ⁄

1 1
4, 2

⁄ ⁄
1

⁄4

1 1
4, 2

⁄ ⁄

FIFTH TERMINAL: For field mounted fifth terminal order catalog number K5T to fit into square opening at the 9 oʼclock
position.
HUBS: For proper hub selection see the hub suffix chart on accessory page.
CONNECTORS: Extruded aluminum connectors are tin plated.

Utility requirements for this equipment may vary. Always consult the serving utility for their requirements before ordering or
installing equipment in this catalog.

B3

200 AMP—4 & 7 TERMINAL—SINGLE POSITION—RING TYPE—600 VAC

METER SOCKETS

SECTION B

B4

U4518-O-W
U3328-RXL

1

3328

4 3 4
5

1

2
6

5

3

2

1
3 3 4

4518

6

5

1

2
4517

3

6

2

4015

5

4

6

200 AMP–SINGLE POSITION–4 TERMINAL–RING TYPE
AMP
200

SERVICE
OH

CATALOG
NUMBER

HUB

U4517-DL-M4

2"

CONNECTORS
CU/AL
#6-350

DIMENSIONS
D"

W"

1

8

1

11

15

1

16

1

#6-350

4

200

UG

U4518-O-W

BLANK

#6-350

4

#6-350

⁄2

15

C.P.

BLANK

1

11

U4518-XL-W

U4015-O

15

1

OH/UG

UG

H"

1

200

200

⁄8

4

CONCENTRIC K.O.ʼS

⁄8
⁄8

6

14

⁄2
⁄2
⁄4

1

2

3

4

21⁄2

21⁄2

21⁄2

—

5
1

⁄4

6
1 1
4, 2

⁄ ⁄

2

2

2

21⁄2

1 1
4, 2

⁄ ⁄

1

2

2

2

21⁄2

1 1
4, 2

1

21⁄2

21⁄2

3

11⁄2

⁄ ⁄

21⁄2

⁄4
⁄4

1 1
4, 2

⁄ ⁄

200 AMP–7 TERMINAL–RING TYPE
AMP
200

SERVICE
OH/UG

CATALOG
NUMBER

HUB

U3328-RXL

C.P.

CONNECTORS
CU/AL
#6-350

DIMENSIONS

CONCENTRIC K.O.ʼS

D"

W"

H"

1

2

3

4

5

7

13

19

3

21⁄2

3

3

1

4

⁄8

⁄4

6
1 1
4, 2

⁄ ⁄

FIFTH TERMINAL: For field mounted fifth terminal order catalog number K5T to fit into square opening at the 9 oʼclock
position.
HUBS: For proper hub selection see the hub suffix chart on the accessory page.
CONNECTORS: Extruded aluminum connectors are tin plated.
SEALING RINGS: The above ring type units are supplied with an MR-4 screw type sealing ring as standard.

Utility requirements for this equipment may vary. Always consult the serving utility for their requirements before ordering or
installing equipment in this catalog.

B4

200 AMP—4 TERMINAL–FLUSH MOUNT—SINGLE POSITION–RING TYPE—600 VAC

B5

SECTION B

3

4

METER SOCKETS

UF4015-KO

UF4518-KO

4

3

4

3

1
1

1

2

2

2

4015
4969

4 5 3 6
4518

3

4517

3

4
5 4 6

5

4

6

200 AMP—4 (1∅3W) TERMINAL—FACTORY WELDED FLUSH MOUNT—RING TYPE
TERM. AMP SERVICE
4
4
4
4

200
200
200
200

OH
OH/UG
UG
UG

CATALOG
NUMBER
UF4517-KO
UF4518-KO
UF4015-KO
UF4969-KO*

HUB CONNECTORS
CU/AL
K.O.
K.O.
K.O.
K.O.

#6-350
#6-350

DIMENSIONS
D"
1

⁄8

5

1

⁄8

5

#6-350

5

#6-350

1

7

⁄2

W"
8
11
14
14

CONCENTRIC K.O.ʼS

H"
15

1

15

1

16

1

16

1

⁄2
⁄2
⁄4
⁄4

1
2
2
1

2

⁄2

1

2

⁄2

2

3

2

2

2

1

2

1

2

2

⁄2

1

2

⁄2

⁄2

1

⁄2

1

2

⁄2

4
2
2
1

2

⁄2

3

5
1

⁄4

⁄ ⁄

1 1
4, 2

6

⁄ ⁄

1 1
4, 2
1

⁄4

1

1 1
4, 2

1

1 1
4, 2

1
1

⁄2
⁄2

⁄ ⁄
⁄ ⁄

FIFTH TERMINAL: For field mounted fifth terminal order catalog number K5T to fit into square opening at the 9 oʼclock position.
CONNECTORS: Extruded aluminum connectors are tin plated.
SEALING RINGS: Ring type units supplied with an MR-4 screw type sealing ring as standard.
* UF4969 can only be used in a 2 x 6 wall.

Utility requirements for this equipment may vary. Always consult the serving utility for their requirements before ordering or
installing equipment in this catalog.

B5

200 AMP—4 & 5 TERMINAL—SINGLE POSITION—RINGLESS
NON-JAW CLAMPING LEVER BYPASS—600 VAC

METER SOCKETS

SECTION B

B6

2

1
2

1

4

5

3

6

3852

4

3

4

1211
9319

4

5

6

U9319-XL

200 AMP—4 TERMINAL—RINGLESS—1∅3W
CONNECTORS
TERM SERVICE
4

OH/UG

CATALOG
NUMBER
U3852-XL

HUB

CU/AL

LINE & LOAD
C.P.

#2-350

BYPASS
LEVER

DIMENSIONS
D"
7

4

⁄8

W"
13

H"
19

CONCENTRIC K.O.ʼS
1

2

3

4

5

3

1

1

1

1

2

⁄2

2

⁄2

2

⁄2

⁄4

6
1 1
4, 2

⁄ ⁄

FIFTH TERMINAL: Fifth terminal is not available for this unit.
TRIPLEX GROUND: Factory installed as standard.

200 AMP—4 & 5 TERMINAL—RINGLESS—1∅3W OR 3∅3W
CONNECTORS
TERM SERVICE
4
5

OH/UG
OH/UG

CATALOG
NUMBER

HUB

U1211-RXL

C.P.

U9319-XL

CU/AL

LINE & LOAD

C.P.

#6-350

BYPASS
LEVER

#6-350

LEVER

DIMENSIONS

CONCENTRIC K.O.ʼS

D"

W"

H"

1

7

13

19

3

4

⁄8

7

4

⁄8

13

19

3

2

3

4

5

1

3

3

1

1 1
4, 2

3

1

1 1
4, 2

2

⁄2

1

2

⁄2

3

⁄4
⁄4

6

⁄ ⁄

FIFTH TERMINAL: For field mounted fifth terminal, order as extra K3866 for the U1211.
HUBS: For proper hub selection see the hub suffix chart on the accessory page.
BYPASS: 200 amp continuous duty bypass. Lever operates bypass only. Not jaw clamping.
CONNECTORS: Units are supplied with extruded aluminum connectors and bonded, triplex neutral.

Utility requirements for this equipment may vary. Always consult the serving utility for their requirements before ordering or
installing equipment in this catalog.

B6

⁄ ⁄

125-200 AMP–7 TERMINAL–SINGLE POSITION–RINGLESS
NON-JAW CLAMPING LEVER BYPASS–600 VAC

SECTION B

6

1

2

6

7573
8100

1

2

3

9320
7422
7423

METER SOCKETS

3

5

U7423-RXL

U7573-RL

4
5

4
6

125 AMP—7 TERMINAL—RINGLESS—3∅4W
AMP

SERVICE

CATALOG
NUMBER

HUB

CONNECTORS
CU/AL

BYPASS

DIMENSIONS
D"

W"

H"

10

18

1

7

10

18

1

OH

U7573-RL

H.O.

#6-2/0

LEVER

4

125

OH

U8100-RL

H.O.

#6-2/0

NONE

4

OH/UG

U9320-RXL

C.P.

#6-2/0

LEVER

CONCENTRIC K.O.ʼS

7

125

125

⁄8
⁄8

7

4

⁄8

13

⁄2
⁄2

19

1

2

3

2

2

2

2

2

2

3

1

⁄2

2

3

4

5

—
—

1 1
4, 2

⁄ ⁄

3

1 1
4, 2

3

3

⁄ ⁄
1

⁄4

6

⁄4
⁄4

1 1
4, 2

⁄ ⁄

200 AMP—7 TERMINAL—RINGLESS—3∅4W
AMP
200
200

SERVICE
OH/UG
OH/UG

CATALOG
NUMBER
U7422-RXL
U7423-RXL

HUB
C.P.
C.P.

CONNECTORS
CU/AL

BYPASS

#6-350

NONE

#6-350

LEVER

DIMENSIONS
D"
7

4

⁄8

7

4

⁄8

W"
13
13

H"
19
19

CONCENTRIC K.O.ʼS
1

2

3

1

3

2

⁄2

1

2

⁄2

3
3
3

4

5

3

1

1 1
4, 2

3

1

1 1
4, 2

⁄4
⁄4

6

⁄ ⁄
⁄ ⁄

HUBS: For proper hub selection, see hub suffix chart in accessories page.
BYPASS: 200 amp continuous duty bypass. Lever operates bypass only. Not jaw clamping.
CONNECTORS: Extruded aluminum connectors are tin plated. Units supplied with bonded, duplex neutral.

Utility requirements for this equipment may vary. Always consult the serving utility for their requirements before ordering or
installing equipment in this catalog.

B7

B7

200 AMP—4, 5 & 7 TERMINAL—SINGLE POSITION—RINGLESS
JAW CLAMPING LEVER BYPASS–600 VAC

METER SOCKETS

SECTION B

B8

U9701-RXL

U9800-RRL

U9551-RXL

6

1

5

6

1

2

3

6

9550
9700
5

3

6

2

1

2

9800

3

4
5

9551
9701

4
6

200 AMP—4 TERMINAL—RINGLESS—1∅3W OR 3∅3W
AMP SERVICE
200
200

CATALOG
NUMBER

OH

U9800-RRL 

OH/UG

U9801-RXL 

HUB
H.O.
C.P.

CONNECTORS BYCU/AL
PASS
#6-350
#6-350

LEVER
LEVER

DIMENSIONS
D"
7

⁄8

4

7

⁄8

4

CONCENTRIC K.O.ʼS

W"

H"

10

1

13

18

⁄2

19

1
3
3

2
1

⁄2

2

1

⁄2

2

3
3
3

4

—
3

5
1 1
4, 2

⁄ ⁄
1

⁄4

6
3

⁄4

1 1
4, 2

⁄ ⁄

200 AMP—5 TERMINAL—RINGLESS—1∅3W OR 3∅3W
AMP SERVICE
200
200

OH
OH/UG

CATALOG
NUMBER

HUB

U9550-RRL

H.O.

U9551-RXL

C.P.

CONNECTORS BYCU/AL
PASS
#6-350
#6-350

LEVER
LEVER

DIMENSIONS
D"

W"

7

10

⁄8

4

7

⁄8

4

13

CONCENTRIC K.O.ʼS

H"
18

1

⁄2

19

1
3
3

2

3

4

5

1

3

—

1 1
4, 2

⁄2

2

1

⁄2

2

3

3

⁄ ⁄
1

⁄4

6
3

⁄4

1 1
4, 2

⁄ ⁄

200 AMP—7 TERMINAL—RINGLESS—3∅4W
AMP

SERVICE

CATALOG
NUMBER

HUB

CONNECTORS
CU/AL

BYPASS

DIMENSIONS
D"

CONCENTRIC K.O.ʼS

W"

H"

7

10

1

7

13

200

OH

U9700-RRL

H.O.

#6-350

LEVER

4

200

OH/UG

U9701-RXL

C.P.

#6-350

LEVER

4

⁄8
⁄8

18

⁄2

19

1

2

3

1

2

3

2

1

⁄2
⁄2

3

4

5

3

—

1 1
4, 2

3

3

⁄ ⁄
1

⁄4

6
3

⁄4

1 1
4, 2

⁄ ⁄

HUBS: For proper hub selection, see hub suffix chart in accessories page.
BYPASS: Lever supplies clamping action and also operates bypass device.
CONNECTORS: Extruded aluminum connectors are tin plated. U9550 and U9551 units are supplied with duplex neutral, with
removable bonding strap for insulated neutral. U9700 series units are supplied with duplex neutral.

 Internal Hex Connectors. For main and/or service disconnect, use with U5484-O enclosed circuit breaker.
Utility requirements for this equipment may vary. Always consult the serving utility for their requirements before ordering or
installing equipment in this catalog.

B8

125-200 AMP—4 & 7 TERMINAL
MANUAL CIRCUIT CLOSING BLOCKS—RING TYPE—600 VAC

B9

SECTION B

3

4
5

METER SOCKETS

2

1

4
6

3504
3507
3514
3517

U3517-XL

U3504-XL

125 AMP—RING TYPE
TERM.
4
7

SERVICE
OH/UG
OH/UG

CATALOG
NUMBER
U3504-XL
U3507-XL

HUB
C.P.
C.P.

CONNECTORS BYCU/AL
PASS
LINK

#6-2/0

LINK

#6-2/0

DIMENSIONS
D"
7

⁄8

4

7

⁄8

4

CONCENTRIC K.O.ʼS

W"

H"

1

2

3

4

5

10

1

2

2

2

2

—

1

2

1

—

10

18

⁄2

21

2

2

2

⁄4

6

⁄4

200 AMP—RING TYPE
TERM.
4
7

SERVICE
OH/UG
OH/UG

CATALOG
NUMBER

HUB

U3514-XL

C.P.

U3517-XL

C.P.

CONNECTORS BYCU/AL
PASS
LINK

#6-350

LINK

#6-350

DIMENSIONS

CONCENTRIC K.O.ʼS

D"

W"

H"

7

13

21

13

1

4

⁄8

7

4

⁄8

24

⁄2

1
1

2

⁄2

1

2

⁄2

2

3

4

5

6

1

3

3

1

1

1

1

1

1

1

2
2

⁄2
⁄2

2

⁄2

2

⁄2

⁄4
⁄4

⁄2
⁄2

FIFTH TERMINAL: For field mounted fifth terminal order catalog number 5T8K2 for the U3504; order K5T for the U3514.
CONNECTORS: Extruded aluminum connectors are tin plated.
SEALING RINGS: Ring type units supplied with an MR-4 screw type sealing ring as standard.
LINK BYPASS: Links provided by utility.

Utility requirements for this equipment may vary. Always consult the serving utility for their requirements before ordering or
installing equipment in this catalog.

B9

B10

320 AMP—4 TERMINAL—SINGLE POSITION—RINGLESS—600 VAC

METER SOCKETS

SECTION B

400 AMP MAX
320 AMP CONTINUOUS

2

1

4

5

3

1129
1797
1819

4

6

2

1
3

3

1079
1432
1431

4

5

6

U1797-O-K3L-K2L

U1129-O-K3L-K2L

320 AMP—4 TERMINAL—RINGLESS—600 VAC
AMP SVC.
320
320

OH
UG

320 OH/UG
320
320
320

UG
UG
UG

CATALOG
NUMBER
U1079-R
U1129-O-K3L-K2L
U1431-R*
U1432-O*
U1819-X*
U1797-O-K3L-K2L

FIFTH
TERM.

CONNECTORS
LINE
3

⁄8"-16 STUDS

K3866

H.O.

K3865

BLANK #4-600 or
(2) 1/0-250

K3866
K3865

DIMENSIONS
BYLOAD PASS D" W" H"

CONCENTRIC K.O.ʼS

CU/AL

HUB

H.O.

3

BLANK

3

TWIN
#6-350

⁄8"-16 STUDS
⁄8"-16 STUDS

3

⁄8"-16 STUDS

K3865

C.P.

K3865

BLANK #4-600 or
(2) 1/0-250

TWIN
#6-350

LEVER
LEVER
NONE
NONE
NONE
LEVER

7

4

⁄8

7

4

⁄8

7

4

⁄8

13

30

13

38

3

29

3

13

7

15

4

⁄8
⁄8

7

4

⁄8

⁄4

15

7

4

38

3

15

⁄4
⁄4

30
30

1
3

2

3

4

5

1

3

3

1

1 1
4, 2
1 1
4, 2

2

3

3

1

3

3

1

1 1
4, 2
1 1
4, 2

3

2

3

⁄ ⁄

1

2

3

⁄4

1

3

3

⁄2

6

⁄2
⁄2

⁄4
⁄4

⁄ ⁄
⁄ ⁄

1

3

3

1

3

3

3

1

1 1
4, 2

3

1

1 1
4, 2

2

⁄2

3

3

⁄4
⁄4
⁄4

⁄ ⁄
⁄ ⁄
⁄ ⁄

HUBS: For proper hub selection, see hub suffix chart in accessories page.
BYPASS: *Lever supplies clamping action on meter spades only on the U1431, U1432 and U1819. Lever supplies clamping
action and also operates bypass device on the U1079, U1129 & U1797.
CONNECTOR KITS: Stud type units are supplied with 3⁄8"-16 hex head nuts with Belleville washers. Order two connector kits to
cover both line and load. Order K1539 (single #350), K1540 (single #600) or K1350 (twin #350). See accessories page.
NOTE: The U1129 unit has a single connector on the line side only.
FIFTH TERMINAL: For field mounted fifth terminal, order as extra K3866 for the U1079 & U1431. Order as extra K3865 for units
U1129, U1432, U1819, and U1797.
LUG SIZE RANGE: See accessories page for lug size range for the U1129 & U1797 units.

Utility requirements for this equipment may vary. Always consult the serving utility for their requirements before ordering or
installing equipment in this catalog.

B10

320 AMP—4 & 7 TERMINAL—SINGLE POSITION–RINGLESS / RING TYPE—600 VAC

2

1

4

3

5056

3

5

2120
2594

4

6

METER SOCKETS

3

SECTION B

1

B11

5

U2120-X
U3548-X

1

2

1

3

4

3548

4
6

5

U5056-O

320 AMP—4 TERMINAL—LINK BYPASS—RING TYPE—1∅3W
CONNECTORS
SERVICE

CATALOG
NUMBER

CU/AL

HUB
LINE

OH/ UG

U3548-X*

C.P.

UG

U5056-O**

BLANK

LOAD

W"

H"

1

2

3

4

5

6

LINK

6

14

33

3

3

3

3

1

⁄4

1 1
4, 2

LINK

6

24

32

3

—

4

1 1
4, 2

⁄ ⁄

1

⁄4

—

#4-600 or
twin 1/0-250

⁄2"-13 STUDS

CONCENTRIC K.O.ʼS

D"

SINGLE = 4-600
PARALLEL = 1/0-250
1

DIMENSIONS

BYPASS

⁄ ⁄

SEALING RING: Ring type units are supplied with an MR-4, screw type, sealing ring as standard.
TRIPLE TAP LUG: For triple tap lug kit order K5049.
LINK BYPASS: Links provided by utility.
*FLUSH MOUNT KIT: For field mounted flush mount kit order K4086.
**This is a PP&L approved unit.

320 AMP—7 TERMINAL—SIDE WIREWAY—RINGLESS
AMP
320
320

SERVICE
UG
OH/UG

CATALOG
NUMBER
U2120-X
U2594-X

HUB

CONNECTORS
CU/AL

C.P.

3

C.P.

3

⁄8"-16 STUDS
⁄8"-16 STUDS

BYPASS
LEVER
LEVER

DIMENSIONS
D"
1

6

H"

3

3

19

1

⁄2 17 ⁄4 31 ⁄4

1

6

W"

CONCENTRIC K.O.ʼS

⁄2

34

⁄8

1
4
—

2
3
3

3
4
4

4
4
4

5

6

1

⁄4

1

⁄4

1
1

⁄2,3⁄4,1

BYPASS: Lever supplies clamping action on meter spades and operates bypass device.
CONNECTOR KITS: Stud type units are supplied with 3⁄8"-16 hex head nuts with Belleville washers. Order two connector kits to
cover both line and load. For single lug connector kits for the U2120 and U2594 units, order as extra K3082 (350 kcmil) or
K3441 (600 kcmil). For twin lug connectors order as extra: K3442 (350 kcmil). Separate kits are required for both line and load.

Utility requirements for this equipment may vary. Always consult the serving utility for their requirements before ordering or
installing equipment in this catalog.

B11

100-125 AMP—4 TERMINAL—HORIZONTAL GANGS–RINGLESS / RING TYPE—300 VAC

METER SOCKETS

SECTION B

B12

U3522-XL

U8032-XL

7

6

1

1

1

4

5

7

3

7

4

5

1

2

7

6

8032

4

3

5

5

1

2

4

3522

100 AMP / POSITION—CONTINUOUS—4 TERMINAL—RINGLESS
NO.
OF SERVICE
POS.

2
3
4
5
6

OH/UG
OH/UG
OH/UG
OH/UG
OH/UG

CATALOG
NUMBER

HUB

U8032-XL
U8033-XL
U8034-XL
U8035-XL
U8036-XL

CONNECTORS
CU/AL

LINE
C.P.
C.P.
C.P.
C.P.
C.P.

#2-350
#2-350
#2-350
#2-350
#2-350

DIMENSIONS

LOAD

D"

#6-2/0

1

1

1

3

1

7

1

1

1

1

#6-2/0
#6-2/0
#6-2/0
#6-2/0

4
4
4
4
4

W"

⁄2 24 ⁄2
⁄2 32 ⁄4
⁄2 40 ⁄8

H"

1

2

3

4

5

6

16

2

2

21⁄2

2

1

⁄2

1 1
4, 2

⁄ ⁄

5

1

⁄2

1 1
4, 2

⁄ ⁄

5

⁄2

1 1
4, 2

⁄ ⁄

5

⁄2

1 1
4, 2

⁄ ⁄

5

⁄2

1 1
4, 2

⁄ ⁄

5

16

2

2

2

⁄2

(3) 2

1

16

2

2

21⁄2

(4) 2

1

2

2

1

2

⁄2

(5) 2

1

2

2

21⁄2

(6) 2

1

⁄2 49 ⁄16 16
⁄2 57 ⁄4

CONCENTRIC K.O.ʼS

16

7

⁄16
⁄16
⁄16
⁄16
⁄16

125 AMP / POSITION—CONTINUOUS—4 TERMINAL—RING TYPE
NO.
OF SERVICE
POS.

2

OH/UG

CATALOG
NUMBER

HUB

U3522-XL-K1

C.P.

CONNECTORS
CU/AL

DIMENSIONS

LINE

LOAD

D"

#2-350

#6-2/0

4

W"

H"

1

2

3

4

5

6

⁄2 241⁄2

14

11⁄2

11⁄2

21⁄2

21⁄2

1 1
4, 2

⁄ ⁄

14

11⁄2

11⁄2

21⁄2

(3)21⁄2 1⁄4,1⁄2

14

11⁄2

11⁄2

21⁄2

(4)21⁄2 1⁄4,1⁄2

⁄2 491⁄16 16

11⁄2

11⁄2

21⁄2

(5)21⁄2 1⁄4,1⁄2

—
—
—
—

1
1

3

OH/UG

U3523-XL-K1

C.P.

#2-350

#6-2/0

4

4

OH/UG

U3524-XL-K2

C.P.

#2-350

#6-2/0

4

5

UG

U3525-XL-K2*

C.P.

#2-350

#6-2/0

4

CONCENTRIC K.O.ʼS

3

⁄2 32 ⁄4

1

⁄2 407⁄8

1

*FOR OVERHEAD SERVICE: The U3525 is factory configured for underground service. If overhead service is desired,
an extension kit is required. Order separately, catalog number K3937.
FIFTH TERMINAL: For field mounted fifth terminal, order catalog number 5T8K2 (6 oʼclock only on 100 amp units,
9 oʼclock only on 125 amp units.)
HUBS: For proper hub selection, see the hub suffix chart in accessories page.
SEALING RINGS: Ring type units are supplied with one MR-4 screw type sealing ring per position.
MAIN BUS RATING: See general engineering page.

Utility requirements for this equipment may vary. Always consult the serving utility for their requirements before ordering or
installing equipment in this catalog.

B12

200 AMP—4 TERMINAL—HORIZONTAL GANGS–RINGLESS / RING TYPE—300 VAC

B13

SECTION B
METER SOCKETS

U1252-X-K1

1

1

3

4

5

2

6

3

4

1

1

1

1252
3532

3

4

2

6

3

5

1

4

4

1
1253-6
3533-6

3

200 AMP / POSITION—4 TERMINAL—RINGLESS
NO.
OF SERVICE
POS.

2
3
4
5
6

OH/UG
OH/UG
UG
UG
UG

CATALOG
NUMBER
U1252-X-K1
U1253-X-K3
U1254-X-K3*
U1255-X-K4*
U1256-X-K4*

HUB

CONNECTORS
CU/AL

LINE
C.P.
C.P.
C.P.

#6-350
#4-600
#4-600

DIMENSIONS

LOAD

D"

#2-350

1

1

1

3

1

7

1

7

1

1

#2-350
#2-350

C.P. (2)#2-600 #2-350
C.P. (2)#2-600 #2-350

W"

⁄8 26 ⁄2

5

⁄8 34 ⁄4

5

⁄8 42 ⁄8

5

⁄8 54 ⁄8

5

H"

1

2

3

14

1

2

⁄2

3

1

1

14

21⁄2

3

(3)21⁄2

1

16

1

2

⁄2

3

(4)2 ⁄2

1

16

21⁄2

3

(5)21⁄2

1

3

(6)2 ⁄2

1

⁄8 63 ⁄16 18

5

CONCENTRIC K.O.ʼS

⁄2

1

2

2

4

⁄2
1

1

5

6

⁄4

1

⁄4

1

⁄4

1

⁄4

1

⁄4

1

⁄2

1

⁄2

1

⁄2

1

⁄2

1

⁄2

1

200 AMP / POSITION—4 TERMINAL—RING TYPE
NO.
OF SERVICE
POS.

2
3

OH/UG
OH/UG

CATALOG
NUMBER
U3532-X-K1
U3533-X-K3

HUB

CONNECTORS
CU/AL

LINE
C.P.
C.P.

#6-350
#4-600

DIMENSIONS

LOAD

D"

#2-350

1

1

1

3

#2-350

5
5

W"

⁄8 26 ⁄2
⁄8 34 ⁄4

CONCENTRIC K.O.ʼS

H"

1

2

3

4

14

21⁄2

3

21⁄2

14

1

3

(3)2 ⁄2

—
—

2

⁄2

1

5

6

⁄4

1

⁄4

1

1
1

*FOR OVERHEAD SERVICE: These units are factory configured for underground service. If overhead service is
desired, an extension kit is required. Order as extra, K3923 (4 & 5 position), K3955 (6 position).
FIFTH TERMINAL: For field mounted fifth terminal order catalog number K5T to fit into square opening at the 9 oʼclock
position.
HUBS: For proper hub selection, see the hub suffix chart in accessories page.
SEALING RINGS: Ring type units are supplied with one MR-4 screw type sealing ring per position.
MAIN BUS RATING: See general engineering page. U1252 & U3532 only rated 400 amp overall.

Utility requirements for this equipment may vary. Always consult the serving utility for their requirements before ordering or
installing equipment in this catalog.

B13

CONDOMINIUM METERING BANKS—RINGLESS

CONDOMINIUM METERING BANKS—RINGLESS

SECTION B

B14

U2854-X-4/125
(Order circuit breakers as extra)

U2866-X

VERTICAL

125 AMP/POSITION

200 AMP/POSITION

NO.
OF
POS.

CATALOG
NUMBER

MAIN BUS
RATING

LINE
CONNECTOR
SIZE

NO.
OF
POS.

CATALOG
NUMBER

MAIN BUS
RATING

LINE
CONNECTOR
SIZE

2

U2852-X

200 AMP

*3/8"-16 STUD

2

U2862-X

250 AMP

*3/8"-16 STUD

3

U2853-X

200 AMP

*3/8"-16 STUD

3

U2863-X

300 AMP

*3/8"-16 STUD

RECTANGULAR

125 AMP/POSITION

200 AMP/POSITION

NO.
OF
POS.

CATALOG
NUMBER

MAIN BUS
RATING

LINE
CONNECTOR
SIZE

NO.
OF
POS.

CATALOG
NUMBER

MAIN BUS
RATING

LINE
CONNECTOR
SIZE

4

U2854-X

400 AMP

*3/8"-16 STUD

4

U2864-X

400 AMP

*3/8"-16 STUD

5

U2855-X

400 AMP

*3/8"-16 STUD

5

U2865-X

600 AMP

*3/8"-16 STUD

6

U2856-X

400 AMP

*3/8"-16 STUD

6

U2866-X

600 AMP

*3/8"-16 STUD

CONNECTOR KITS *
SIZE

SUFFIX

KIT
COMPATIBLE
NUMBER
WITH

-K1

K1539

-K3

K1540

SINGLE

-K2

K1350

-K4

K1541

TWIN

U2852-56
U2862-66
U2854-56
U2864-66
U2854-56
U2863-66
U2864-66

WIRE
RANGE
#6-350

*CONNECTORS: For line wire connector kits, order separately.
FIFTH TERMINALS: For field mounted fifth terminal order catalog
number K2381. Order one per meter position (9 oʼclock position
only).
BREAKERS: Units have provision for one double pole main per
meter position. Breakers not included. Order as extra Milbank.

PLUG-IN BREAKER COMPATIBILITY CHART
#4-600
AMPS

#6-350

125-200 HQP / BR / WBJ

#2-600

≤ 100

SIEMENS
MURRAY /
CROUSE-HINDS

G.E.

SQ-D

—

MD

THQ

—

QP

MP

THQ

HOMELINE

CUTLER-HAMMER SIEMENS
(WESTINGHOUSE) (ITE)

QP / BR / HQP

Utility requirements for this equipment may vary. Always consult the serving utility for their requirements before ordering or
installing equipment in this catalog.

B14

CONDOMINIUM METERING BANKS

B15

VERTICAL
125 amp/pos.
(2-3 position)

D

200 amp/pos.
(2-3 position)

D

SECTION B

125 &200 amp/pos.
(single position)

D

21"

C

B

A
25" or
37"

C

13"
or
18"

29" or
41"

5 13/16"

5 13/16"

E E E B C
18"
E

E

E

U2852-X

B

C

5 13/16"

21"

CONDOMINIUM
METERING BANKS

RECTANGULAR
125 amp/pos.
(4,5 & 6 position)

200 amp/pos.
(4,5 & 6 position)

D

FIG.

DIMENSIONS

A

11⁄4" CONCENTRIC K.O.

B

1

D

37" or
25"
29" or
41"

⁄4,1⁄2" CONCENTRIC K.O.

C

3" CONCENTRIC K.O.

D

4" HUB OPENING

E

2" CONCENTRIC K.O.

A

A

A

B

C
31"

A

A

A

4 7/8"
E

E

E

B

C

E

E

E

4 7/8"

36"

Utility requirements for this equipment may vary. Always consult the serving utility for their requirements before ordering or
installing equipment in this catalog.

B15

CONDOMINIUM METERING BANKS

A

NOTES

SECTION B

B16
NOTES

B16

200 AMP—4 & 7 TERMINAL—METER MAIN—RING TYPE—240 VOLT

SECTION C

1
2

3584
3587

3
4

4

3

METER MAINS AND SERVICE ENTRANCE EQUIPMENT

2

1

4

5

3574
3577

U3574-RL-200

200 AMP—4 & 7 TERMINAL—RING TYPE
NO.
OF
SERVICE
TERMS
4
7
4
7

OH
OH
UG
UG

CATALOG
NUMBER

BREAKER

U3574-RL-200

200A-2P

U3577-RL-200
U3584-O-200
U3587-O-200

200A-3P
200A-2P
200A-3P

CONNECTORS
CU/AL

DIMENSIONS

CONCENTRIC K.O.ʼS

LINE

LOAD

D"

W"

H"

1

2

3

#2-350

#3-300

4

1

8

30

2

2

21⁄2

1

10

34

2

2

21⁄2

1

#2-350
#6-350
#6-350

#3-300
#3-300
#3-300

⁄8

7

4

⁄8

1

1

1

1

5
5

⁄2 14 ⁄8
⁄2 14 ⁄8

4

5

6

⁄4

1 1
4, 2

⁄ ⁄

⁄4

1 1
4, 2

⁄ ⁄

—
—

—
—
—
—

26

3

3

3

1 1
4, 2

26

3

3

3

1 1
4, 2

⁄ ⁄

⁄ ⁄

BREAKERS: Units are supplied with bolt-on 200 amp circuit breakers where specified above.
SEALING RINGS: Units are supplied with an MR-4 screw type sealing ring.

Utility requirements for this equipment may vary. Always consult the serving utility for their requirements before ordering or
installing equipment in this catalog.

C1

C1

100/150/200 AMP–RING TYPE / RINGLESS METER MAINS–4 & 5 TERMINAL–22K AIC

SECTION C

C2

1

3

5

6

1

4

2

5

5

6

5

6

METER MAINS AND SERVICE ENTRANCE EQUIPMENT

U5168-XTL-200

5168
5169
5268
5269

U5268-XTL-200-KK

100/150/200 AMP–4 & 5 TERMINAL–METER MAIN–22K AIC–120/240 VOLT–1∅3W–RINGLESS / RING TYPE
OVERHEAD / UNDERGROUND–8 & 20 CIRCUIT INTERIOR
NO. OF
TERMS AMP CIRCUITS
4
4
4
4
4
4
5
5
4
4
4
4
4
4
4
4

100
150
200
100
150
200
100
150
100
150
200
150
200
150
200
200

10
8
8
10
8
8
10
8
10
8
8
20
20
20
20
20

CATALOG
NUMBER
U5168-XTL-100 **
U5168-XTL-150 **
U5168-XTL-200 **
U5168-XTL-100-KK **
U5168-XTL-150-KK **
U5168-XTL-200-KK **

CONNECTORS
HUB
LINE
C.P.
C.P.
C.P.
C.P.
C.P.
C.P.

U5168-XTL-100-KK-5T ** C.P.
U5168-XTL-150-KK-5T ** C.P.
U5169-XTL-100
U5169-XTL-150
U5169-XTL-200
U5268-XTL-150 **
U5268-XTL-200 **
U5268-XTL-150-KK **
U5268-XTL-200-KK **
U5269-XTL-200

C.P.
C.P.
C.P.
C.P.
C.P.
C.P.
C.P.
C.P.

#6-350
#6-350
#6-350
#6-350
#6-350
#6-350
#6-350
#6-350
#6-350
#6-350
#6-350
#6-350
#6-350
#6-350
#6-350
#6-350

DIMENSIONS
BYPASS D" W" H"
NONE
NONE
NONE
HORN
HORN
HORN
HORN
HORN
NONE
NONE
NONE
NONE
NONE
HORN
HORN
NONE

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4

⁄2 14 ⁄8 32
⁄2 14 ⁄8 32
⁄2 14 ⁄8 32
⁄2 14 ⁄8 32
⁄2 14 ⁄8 32
⁄2 14 ⁄8 32
⁄2 14 ⁄8 32
⁄2 14 ⁄8 32
⁄2 14 ⁄8 32
⁄2 14 ⁄8 32
⁄2 14 ⁄8 32
⁄2 14 ⁄8 32
⁄2 14 ⁄8 32
⁄2 14 ⁄8 32
⁄2 14 ⁄8 32
⁄2 14 ⁄8 32

CONCENTRIC K.O.ʼS
1
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2

2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2

3

4

3

1

1 3
⁄2, ⁄4, 1 1 2 3 4

1

1 3
⁄2, ⁄4, 1 1 2 3 4

1

1 3
⁄2, ⁄4, 1 1 2 3 4

1

1 3
⁄2, ⁄4, 1 1 2 3 4

1

1 3
⁄2, ⁄4, 1 1 2 3 4

1

1 3
⁄2, ⁄4, 1 1 2 3 4

1

1 3
⁄2, ⁄4, 1 1 2 3 4

1

1 3
⁄2, ⁄4, 1 1 2 3 4

1

1 3
⁄2, ⁄4, 1 1 2 3 4

1

1 3
⁄2, ⁄4, 1 1 2 3 4

1

1 3
⁄2, ⁄4, 1 1 2 3 4

1

1 3
⁄2, ⁄4, 1 1 2 3 4

1

1 3
⁄2, ⁄4, 1 1 2 3 4

1

1 3
⁄2, ⁄4, 1 1 2 3 4

1

1 3
⁄2, ⁄4, 1 1 2 3 4

1

1 3
⁄2, ⁄4, 1 1 2 3 4

3
3
3
3
3
3
3
3
3
3
3
3
3
3
3

2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2

⁄2
⁄2
⁄2
⁄2
⁄2
⁄2
⁄2
⁄2
⁄2
⁄2
⁄2
⁄2
⁄2
⁄2
⁄2
⁄2

5

6

⁄,⁄
⁄,⁄
⁄,⁄
⁄,⁄
⁄,⁄
⁄,⁄
⁄,⁄
⁄,⁄
⁄,⁄
⁄,⁄
⁄,⁄
⁄,⁄
⁄,⁄
⁄,⁄
⁄,⁄
⁄,⁄

HUB: Supplied with (2) closing plates packed inside. Order hubs as a separate item. See accessory page for hub options.
INTERIOR: U5168 units have 8-circuit interior; U5268 units have 20-circuit interior.
FIFTH TERMINAL: Order K5T and field install for 208Y/120 network systems. Installs in the 9 oʼclock position only.
BREAKERS: Rated 22K AIC with Milbank QNR2200H main installed.
INTERLOCK KIT: For generator auxiliary circuit breaker interlock, order K5815 for large QN with small frame Q; order K5820 for
large frame QN with large frame QN.
SUB-FEED LUGS: #6-350 kcmil sub-feed lugs provided on 8 and 10 circuit interior. Not available on 20 circuit interior.
*Amperage rating limited to main breaker rating. Interior has 10 branch circuit breaker provisions.
**RINGLESS

Utility requirements for this equipment may vary. Always consult the serving utility for their requirements before ordering or
installing equipment in this catalog.

C2

200 AMP—4 TERMINAL—SERVICE ENTRANCE
MAIN BREAKER—UNMETERED—120/240 VAC

C3

26"

SECTION C

8"
1

2

4
4

USE-AP

N

A

B

N

A

B

USE-AP-200-ML
G
G

USE-AP-200-ML

USE-AP-200-MB

200 AMP—4 TERMINAL—BREAKER ENCLOSURE—1∅3W, 120/240V—10K AIC RATING
NO.
OF
TERM.

4
4

SERVICE

OH
OH

CATALOG
NUMBER
USE-AP-200-MB
USE-AP-200-ML

CONNECTORS

DIMENSIONS

CONCENTRIC K.O.ʼS

HUB
LINE
2"

#4-250

2"

#4-250

D"
5
5

W"
8
8

H"
26
26

1
1
1

2

3

4

2

1 3
2, 4

⁄ ⁄

1 3
2, 4

2

1 3
2, 4

1 3
2, 4

⁄ ⁄

⁄ ⁄
⁄ ⁄

NOTE: The neutral bus / ground bar is factory installed.
USE-AP-200-MB: 200 Amp main wired in series with plug-in style bus. UQFP-M-200 factory installed Additional 4
branch circuits available for (1) two-pole and (2) one-pole, or (4) one pole breakers. One 2" hub included.
USE-AP-200-ML: 200 Amp breaker wired in parallel with plug-in style bus. UQFP-200 factory installed. Additional 4
branch circuits available for (1) two-pole and (2) one-pole, or (4) one pole breakers. One 2" hub included.

Utility requirements for this equipment may vary. Always consult the serving utility for their requirements before ordering or
installing equipment in this catalog.

C3

METER MAINS AND SERVICE ENTRANCE EQUIPMENT

5"

3

400 AMP—320 AMP CONTINUOUS
METER MAIN WITH SPLIT LOAD—120/240 VAC

METER MAINS AND SERVICE ENTRANCE EQUIPMENT

SECTION C

C4

1

3

4

5059
5759

1

4

2

5

M400-PAR-UG

5

U4031-O-2/200

U5059-X-2/200

1

3

4

1

2

1
5

M400-PAR

3

4

3

5

2

1

5

4031

4

4 TERMINAL—1∅3W—RINGLESS / 22K AIC
SERV.

CATALOG
NUMBER

PRIMARY
DISCONNECT

OH

M400-PAR 

200 Amp / 2 Pole
Circuit Breaker
200 Amp / 2 Pole
Circuit Breaker
200 Amp / 2 Pole
Circuit Breaker
200 Amp / 2 Pole
Circuit Breaker
200 Amp / 2 Pole
Circuit Breaker

UG M400-PAR-UG** 
UG U4031-O-2/200 
OH/UG U5059-X-2/200 
OH/UG U5759-X-2/200*

DIMENSIONS
SECONDARY BYDISCONNECT PASS D" W" H"
See note 
See note 

LEVER
LEVER

1

6

⁄8

1

6

1

9

1

200 Amp / 2 Pole LEVER
5 ⁄4
Circuit Breaker
7
200 Amp / 2 Pole LEVER
4 ⁄8
Circuit Breaker
7
200 Amp / 2 Pole NONE
4 ⁄8
Circuit Breaker

1

2

⁄2 47 ⁄8

2

2

1

1

1

⁄8 22 ⁄8 36

3

CONCENTRIC K.O.ʼS

25
15
15

30
42
42

2

⁄2

3
3
3

2

⁄2

3
3
3

3
2
4
4
3
3

4

5

1

1 3
2, 4

1

1 3
2, 4

⁄2

1

⁄2

2

⁄ ⁄
⁄ ⁄

3

1 1
4, 2

1

1 1
4, 2

1

1 1
4, 2

⁄4
⁄4

⁄ ⁄
⁄ ⁄
⁄ ⁄

NEUTRAL: Bonded neutral and ground factory Installed.
FLUSH MOUNT: Flush mounting available on underground units. Order catalog number FK-M400-UG separately.
SHORT CIRCUIT CURRENT WITHSTAND RATING: 22K AIC Standard.
BYPASS: Lever supplies clamping action and operates bypass device.
FIFTH TERMINAL: For field installed fifth terminal for the U5059 & U5759, order separately catalog number K3866.
CONVERSION KIT: To field convert M400 UG units to OH, order K4787-R. Includes connectors (#2-600).

 200 amp primary disconnect factory installed. Order secondary disconnect separately. Specify UQFPH-100, 125, 150,
175 or 200.

 OVERHEAD: Includes one 3" hub.
 Provided with connectors for #4-600 or twin 1/0-250.
 LINE SIDE CONNECTOR KITS: Two 1/2" studs per phase on 1 3/4" centers. Factory installed for the U5759, for
the U5059 order anti-rotation connector kit K1540L to accommodate #4-600 kcmil single or K1350L for twin 350
kcmil connectors.
*Lever supplies clamping action only–does NOT operate bypass on the U5759.
**LUG KIT: Mechanical lug kit available for M400-APS-UG, order K4920 (#2-500).

Utility requirements for this equipment may vary. Always consult the serving utility for their requirements before ordering or
installing equipment in this catalog.

C4

400 AMP—320 AMP CONTINUOUS
METER MAIN WITH SPLIT LOAD—120/240 VAC

C5

SECTION C

3

2

1

4

METER MAINS AND SERVICE ENTRANCE EQUIPMENT

1

5
5

M400-APS-BS

4 TERMINAL—1∅3W—TYPE 3R—RING TYPE —120/240 VAC
SERV
OH
OH

CATALOG
NUMBER
M400-APS
M400-APS-BS

DIMENSIONS
PRIMARY
SECONDARY BYDISCONNECT DISCONNECT PASS D" W" H"
200 Amp / 2 Pole
Circuit Breaker
200 Amp / 2 Pole
Circuit Breaker

See note 
See note 

NONE
LINK

1

6

⁄8

6

1

9

11

1

⁄2 47 ⁄8

1

⁄2 47

CONCENTRIC K.O.ʼS
1

2

2
1- 2

3

2
1

2
1

⁄2 2- 2 ⁄2 3-3

4

5

1

1 3
2, 4

4-3

1

1

⁄2

⁄ ⁄

5

⁄2

6
—
3

⁄4

EUSERC: Meets EUSERC requirements. Consult local utility for acceptability before ordering or installing.
NEUTRAL: Bonded neutral and ground factory Installed.
LINE SIDE CONNECTORS: Connectors provided for 4-600 or twin 1/0-250.
OVERHEAD: Overhead units include one 3" hub.

 200 amp primary disconnect factory installed. Order secondary disconnect separately. Specify UQFPH-100, 125, 150,
175 or 200.

Utility requirements for this equipment may vary. Always consult the serving utility for their requirements before ordering or
installing equipment in this catalog.

C5

400 AMP—320 AMP CONTINUOUS
METER MAIN WITH SPLIT LOAD—120/240 VAC

METER MAINS AND SERVICE ENTRANCE EQUIPMENT

SECTION C

C6

1

3

4

1

4

2

5

FIG. 1

5

1

1

2

4

4

FIG. 2

M400-UG-APS-LC

U3251-O-200-CB

(see next page for dwg. & chart)

3

5

4 TERMINAL—1∅3W–TYPE 3R—RING TYPE PLUG-IN SOCKETS—120/240 VAC
SERV
UG
UG
UG
UG
UG
UG

CATALOG
NUMBER

DIMENSIONS
PRIMARY
SECONDARY BYDISCONNECT DISCONNECT PASS D" W" H"

200 Amp / 2 Pole
See note 
Circuit Breaker
200
Amp
/
2
Pole
M400-UG-APS-F-BS  Circuit Breaker
See note 
200 Amp
200 Amp
M400-UG-APS-P 
2 Pole—T-Fuse 2 Pole—T-Fuse
200 Amp / 2 Pole 200 Amp / 2 Pole
M400-UG-APS-LC 
Circuit Breaker
Circuit Breaker
200
Amp
/
2
Pole
200
Amp / 2 Pole
M400-UG-APS-LC-BS  Circuit Breaker
Circuit Breaker
Amp / 2 Pole 200 Amp / 2 Pole
U3251-O-200-CB  200
Circuit Breaker
Circuit Breaker

M400-UG-APS-F 

NONE
LINK
NONE

1

6

⁄8 221⁄8 36

6

29 41

7

⁄16

1

6

⁄8 221⁄8 36

NONE

6

29 41

7

LINK

6

29 41

7

24

1

LINK

3

6

⁄4

⁄16

40

⁄16
⁄4

CONCENTRIC K.O.ʼS
1
1

2

⁄2

2
1

2

1

2

1

2

1
2

⁄2
⁄2

1

2

1

2

1

⁄2
⁄2

3

⁄2

1

1

1

⁄2
⁄2

1

⁄2

1

⁄2

3

3
4
4
4
4
4
4

FIG.

4

5

1

1 3
2, 4

⁄ ⁄

1

⁄4

1

—

1

1 3
2, 4

⁄ ⁄

1

1

—

⁄4

1

—

3

1 3
2, 4

2

⁄2

2

3

⁄2

2

3

⁄4

3

⁄ ⁄

EUSERC: Meets EUSERC requirements. Consult local utility for acceptability before ordering or installing.
NEUTRAL: Bonded neutral and ground factory Installed.
LINE SIDE CONNECTORS: Two 1/2" studs per phase on 1 3/4" centers.
LOAD SIDE CONNECTORS: 1/0-300
FLUSH MOUNT: Flush mount kit included with M400-UG-APS-F, M400-UG-APS-BS, M400-UG-APS-LC and
M400-UG-APS-LC-BS. Available for other underground units. Order catalog number FK-M400-UG separately.
SHORT CIRCUIT CURRENT WITHSTAND RATING: 22K AIC standard, 200K AIC standard on T-fuse models.
LUG KIT: Mechanical lug kit available, order K4920 (#2-500).
CONVERSION KIT: To field convert M400 UG units to OH, order K4787-R. Includes connectors (#2-600).

 200 amp primary disconnect factory installed. Order secondary disconnect separately. Specify UQFPH-100, 125, 150, 175 or 200.
 Two 200 amp T-fuse pull-outs factory installed as primary and secondary disconnects.
 Two 200 amp 2-pole bolt-on UQFBH main breakers factory installed.
 BREAKERS: Two 200 Amp 2-pole main breakers factory installed, and semi-flush flange kit packed inside meter section.
Universal Copper 24 / 40 Circuit interior accepts Challenger, GE, Murrary, Siemens / ITE, and Cutler-Hammer / Westinghouse
universal type plug-in branch circuit breakers.

Utility requirements for this equipment may vary. Always consult the serving utility for their requirements before ordering or
installing equipment in this catalog.

C6

400 AMP—320 AMP CONTINUOUS—METER MAIN COMBINATION

SECTION C

1

C7

1
2
4

2

(9)

5 (4)
4

METER MAINS AND SERVICE ENTRANCE EQUIPMENT

1

5

4(32)
3

3

2

6

M400-UG-APS-LC

M401-UG

(see previous page for details)

400 AMP MAIN BREAKER—4 TERMINAL—1∅3W—TYPE 3R—RING TYPE–120/240 VAC
SERV.

UG
UG

CATALOG
NUMBER

MAIN
DISCONNECT

M401-UG

(1) 400 AMP
2 POLE BREAKER
(1) 400 AMP
2 POLE BREAKER

M401-UG-BS

CONNECTORS
CU/AL

LINE

DIMENSIONS
BYLOAD PASS D" W" H"

STUDS C.B.
STUDS C.B.

NONE
LINK

6
6

24
24

38
38

CONCENTRIC K.O.ʼS
1

2

3

1

1

1

2

⁄2

1

2

⁄2

3

⁄2

1

3

⁄2

3

⁄2

1

3

⁄2

4

5

6

4

1

1

4

1

1

⁄4
⁄4

⁄2
⁄2

EUSERC: Meets EUSERC requirements. Consult local utility for acceptability before ordering or installing.
NEUTRAL: Bonded neutral and ground factory installed.
LINE SIDE CONNECTORS: Two 1/2" studs per phase on 1-3/4" centers.
LUG KIT: Mechanical lug kit available, order K4920 (#2-500).
FLUSH MOUNT: Flush mount kits are NOT available for these units.
SHORT CIRCUIT CURRENT WITHSTAND RATING: 22K AIC standard.
 CB load side (1) or (2) copper conductors 3/0-500, (2) aluminum conductors 4/0-500 or (1) aluminum conductor 250-500.

Utility requirements for this equipment may vary. Always consult the serving utility for their requirements before ordering or
installing equipment in this catalog.

C7

400 AMP—320 AMP CONTINUOUS—METER MAIN COMBINATION

METER MAINS AND SERVICE ENTRANCE EQUIPMENT

SECTION C

C8

5
6

7

1 2 3 4 6

8

CONCENTRIC K.O.ʼS
1=
2=
3=
4=
5=
6=
7=
8=

(12)
(4)
(4)
(2)
(3)
(4)
(1)
(4)

1/2" K.O.
1/2, 3/4
3/4, 1"
1/2, 3/4, 1, 1 1/4"
3/4, 1, 1 1/4, 1 1/2"
1, 1 1/4, 1 1/2, 2"
3, 3 1/2, 4"
1/4 diameter hole

M404-UG-LC

400 AMP MAIN WITH CIRCUIT LOAD CENTER—4 TERMINAL—1∅3W
RING TYPE—120/240 VAC
SERV.

UG
UG

CATALOG
NUMBER

PRIMARY
DISCONNECT

M404-UG-LC*

400 AMP
2 POLE BREAKER
400 AMP
2 POLE BREAKER

M404-UG-LC-BS*

SECONDARY
DISCONNECT
N/A
N/A

DIMENSIONS
BYPASS D" W" H"
NONE

LINK

6
6

34 47
34 47

CONCENTRIC K.O.ʼS
1

7

8

⁄4 1 ⁄2 2

4

1

⁄2 1⁄2,3⁄4 1 11⁄4 11⁄2 2

4

1

1

2
1 3
2, 4

⁄2 ⁄ ⁄

3
1

4

5

1

1

1

1

6

EUSERC: Meets EUSERC requirements. Consult local utility for acceptability before ordering or installing.
NEUTRAL: Bonded neutral and ground factory installed.
LINE SIDE CONNECTORS: (2) 1/2" studs per phase on 1-3/4" centers.
LUG KIT: Mechanical lug kit available, order K4920 (#2-500).
FLUSH MOUNT: Flush mounting available on underground units. Order catalog number FK-M404-UGLC separately.
SHORT CIRCUIT CURRENT WITHSTAND RATING: 22K AIC standard.
BRANCH BREAKERS: Use Siemens, Cutler-Hammer, GE or Siemens/Murray breakers to maintain 22K rating.
* Includes a 30-circuit load center.

Utility requirements for this equipment may vary. Always consult the serving utility for their requirements before ordering or
installing equipment in this catalog.

C8

⁄4
⁄4

TEST BLOCK BYPASS—TB SERIES
100/200 AMP—600 VOLT SELF CONTAINED / SOCKET ONLY

D1

These UL Listed products
are for use in areas
requiring Electrical Utility
Service Equipment
Requirements Committee
(EUSERC) compliance.

5

4

4

SECTION D

2

1

1

3

114TB
115TB
117TB

2

1
6

3

4

124TB
125TB
127TB

127TB

114TB

100 AMP—4, 5 & 7 TERMINAL— FOR USE WITH REMOTE MAIN—RING TYPE
NO.
TYPE
OF
OF
TERM. SERVICE

4
5
7

OH/UG

CATALOG
NUMBER
114TB*

OH/UG

115TB

OH/UG

117TB

CONNECTORS
CU/AL
LINE & LOAD
#6-1/0
#6-1/0
#6-1/0

TYPE
OF
SERVICE
1∅3W *
3∅3W
3∅4W

DIMENSIONS
D"
5

4

⁄8

5

4

⁄8

5

4

⁄8

CONCENTRIC K.O.ʼS

W"

H"

1

2

3

4

5

6

12

25

2

2

11⁄2

2

1

⁄2

1

—
—
—

12

25

2

2

1

⁄2

2

1

⁄2

12

25

2

2

11⁄2

2

1

⁄2

200 AMP—4, 5 & 7 TERMINAL—FOR USE WITH REMOTE MAIN—RING TYPE
NO.
TYPE
OF
OF
TERM. SERVICE

CATALOG
NUMBER

CONNECTORS
CU/AL
LINE & LOAD

TYPE
OF
SERVICE

D"

W"

H"

1

2

3

4

DIMENSIONS

CONCENTRIC K.O.ʼS
5

6

⁄32

1

⁄32

1

⁄32

1

4

OH/UG

124TB*

#1/0-250

1∅3W *

6

14

30

21⁄2

21⁄2

3

3

9

5

OH/UG

125TB

#1/0-250

3∅3W

6

14

30

21⁄2

21⁄2

3

3

9

30

1

3

9

7

OH/UG

127TB

#1/0-250

3∅4W

6

14

2

⁄2

⁄2

1

2

3

⁄2
⁄2
⁄2

HUBS: OH units use hub up to 21⁄2" (see accessory page). Units provided with closing plates.
SEALING RINGS: Units furnished with MR-2 snap style sealing rings.
NEUTRAL: “Lay-in” connectors will accommodate #6-2/0 (for 100 amp units) and #2-250 (for 200 amp units) copper or
aluminum wire.
RING PROTECTOR: Add suffix -RP to catalog number for factory installed ring protector (ex. 117TB becomes 117TB-RP).
* For 3W (208Y/120) network service, install field mounted fifth terminal catalog number 105J. See accessories page.

SHORT CIRCUIT CURRENT WITHSTAND RATING UP TO 200K AIC DEPENDING ON
OVERCURRENT PROTECTION DEVICE USED
Utility requirements for this equipment may vary. Always consult the serving utility for their requirements before ordering or
installing equipment in this catalog.

D1

COMMERCIAL METERING–SAFETY SOCKETS, METER MAINS,
TERMINATION BOXES, BUSSED GUTTERS

5

4

D2

TEST BLOCK BYPASS—MTB SERIES—100 AMP—10K AIC
240 VOLT SELF CONTAINED METER MAIN / CIRCUIT BREAKERS

COMMERCIAL METERING–SAFETY SOCKETS, METER MAINS,
TERMINATION BOXES, BUSSED GUTTERS

SECTION D

These UL Listed products
are for use in areas
requiring Electrical Utility
Service Equipment
Requirements Committee
(EUSERC) compliance.

1
5 5

4

3

4

6

2
U214MTB
U215MTB
U217MTB

U214MTB
217MTB
2

1
5

6

3

4

4

214MTB
215MTB
217MTB

100 AMP—4, 5, & 7 TERMINAL—240 VOLT—BREAKER INSTALLED—RING TYPE
NO.
TYPE
OF
OF
TERM. SERVICE

CATALOG
NUMBER

CONNECTORS
LINE

TYPE

LOAD
OF
NEUTRAL SERVICE

DIMENSIONS
D"
5

4

OH

214MTB*

#6-2/0

#14-1/0 1∅3W *

4

5

OH

215MTB

#6-2/0

#14-1/0

4

3∅3W

7

OH

217MTB

#6-2/0

#14-1/0

4

OH/UG

U214MTB*

#6-2/0

#14-1/0 1∅3W *

3∅4W

⁄8

5

⁄8

5

4

⁄8

5

4

⁄8

5

5

OH/UG

U215MTB

#6-2/0

#14-1/0

3∅3W

4

7

OH/UG

U217MTB

#6-2/0

#14-1/0

3∅4W

4

⁄8

5

⁄8

W"

H"

CONCENTRIC K.O.ʼS
1

2

3

4
1

5

6

⁄32

1

⁄32

1

12

34

2

2

2

1

⁄2

9

12

34

2

2

2

11⁄2

9

1

⁄2

9

⁄32

1

2

3

2
2
2

12

34

2

2

2

18

25

2

2

21⁄2
1

1

⁄4

18

25

2

2

2

⁄2

2

3

18

25

2

2

21⁄2

2

3

⁄4
⁄4

⁄2
⁄2
⁄2

REPLACEMENT MAIN DISCONNECTS: For replacement main disconnect see pages D14 & D15.
HUBS: OH units use hub up to 21⁄2" (see accessory page). Units provided with closing plate.
SEALING RINGS: Units furnished with MR-2 snap style sealing rings.
NEUTRAL: “Lay-in” connectors will accommodate #6-2/0 (for 100 amp units) and #2-250 (for 200 amp units) copper or
aluminum wire.
* For 3W (208Y/120) network service, install field mounted fifth terminal catalog number 105J. See accessories page.

Utility requirements for this equipment may vary. Always consult the serving utility for their requirements before ordering or
installing equipment in this catalog.

D2

TEST BLOCK BYPASS—MTB SERIES—100 AMP—22K AIC
240 VOLT—SELF CONTAINED METER MAIN / CIRCUIT BREAKER

D3

These UL Listed products
are for use in areas
requiring Electrical Utility
Service Equipment
Requirements Committee
(EUSERC) compliance.

5

6

3

4

SECTION D

2

1

4

214MTB/22
217MTB/22

217MTB/22
1

2

6

U214MTB/22
U217MTB/22

5 5

4

3

4

100 AMP—4 & 7 TERMINAL—240 VOLT—BREAKER INSTALLED—RING TYPE
NO.
TYPE
OF
OF
TERM. SERVICE

4
7
4
7

OH
OH

CATALOG
NUMBER
214MTB/22*
217MTB/22

OH/UG U214MTB/22*
OH/UG

U217MTB/22

CONNECTORS

TYPE

DIMENSIONS

LINE

LOAD
OF
NEUTRAL SERVICE

D"

#6-2/0

#14-1/0 1∅3W *

4

#6-2/0
#6-2/0
#6-2/0

#14-1/0

3∅4W

#14-1/0 1∅3W *
#14-1/0

3∅4W

5

⁄8

5

4

⁄8

5

4

⁄8

5

4

⁄8

CONCENTRIC K.O.ʼS

W"

H"

1

2

3

4

5

6

12

34

2

2

2

11⁄2

9

⁄32

1

12

34

2

2

2

11⁄2

9

⁄32

1

1

2
2

18

25

2

2

2

⁄2

2

3

18

25

2

2

21⁄2

2

3

⁄4
⁄4

⁄2
⁄2

REPLACEMENT MAIN DISCONNECTS: For replacement main disconnect see pages D14 & D15.
* For 3W (208Y/120) network service, install field mounted fifth terminal catalog number 105J. See accessories page.
HUBS: OH units use hub up to 21⁄2" (see accessory page). Units provided with closing plate.
SEALING RINGS: Units furnished with MR-2 snap style sealing rings.
NEUTRAL: “Lay-in” connectors will accommodate #6-2/0 (for 100 amp units) and #2-250 (for 200 amp units) copper or
aluminum wire.

Utility requirements for this equipment may vary. Always consult the serving utility for their requirements before ordering or
installing equipment in this catalog.

D3

COMMERCIAL METERING—SAFETY SOCKETS, METER
MAINS, TERMINATION BOXES, BUSSED GUTTERS

U214MTB/22

D4

TEST BLOCK BYPASS—MTB SERIES—100 AMP—14K AIC
480 VOLT—SELF CONTAINED METER MAIN / CIRCUIT BREAKER
These UL Listed products
are for use in areas
requiring Electrical Utility
Service Equipment
Requirements Committee
(EUSERC) compliance.

2

1
5

6

3

4

COMMERCIAL METERING–SAFETY SOCKETS, METER MAINS,
TERMINATION BOXES, BUSSED GUTTERS

SECTION D

4

214MTB-48
215MTB-48
217MTB-48

1

2
U214MTB-48
U215MTB-48
U217MTB-48

5 5

4

3

4

6

U214MTB-48

217MTB-48

100 AMP—4, 5 & 7 TERMINAL—480 VOLT—BREAKER INSTALLED—RING TYPE
NO.
TYPE
OF
OF
TERM. SERVICE

CATALOG
NUMBER

CONNECTORS
LINE

LOAD
NEUTRAL

TYPE
OF
SERVICE

D"

W"

H"

1

2

3

4

DIMENSIONS

CONCENTRIC K.O.ʼS
5

6

⁄32

1

⁄32

1

⁄32

1

⁄4

2

⁄4

2

⁄4

2

4

OH

214MTB-48*

#6-250

#14-1/0

1∅3W

6

14

48

21⁄2

21⁄2

3

3

9

5

OH

215MTB-48

#6-250

#14-1/0

3∅3W

6

14

48

21⁄2

21⁄2

3

3

9

7

OH

217MTB-48

#6-250

#14-1/0

3∅4W

6

14

48

21⁄2

21⁄2

3

3

9

#6-250

#14-1/0

1∅3W

18

25

2

2

21⁄2

2

3

18

25

2

2

21⁄2

2

3

18

25

2

2

21⁄2

2

3

4

OH/UG U214MTB-48*

5

4

⁄8

5

5

OH/UG

U215MTB-48

#6-250

#14-1/0

3∅3W

4

7

OH/UG

U217MTB-48

#6-250

#14-1/0

3∅4W

4

⁄8

5

⁄8

⁄2
⁄2
⁄2

REPLACEMENT MAIN DISCONNECTS: For replacement main disconnect see pages D14 & D15.
HUBS: OH units use hub up to 21⁄2" (see accessory page.) Units provided with closing plate.
SEALING RINGS: Units furnished with MR-2 snap style sealing rings.
NEUTRAL: “Lay-in” connectors will accommodate #6-2/0 aluminum wire.
* For 3W (208Y/120) network service, install field mounted fifth terminal catalog number 105J. See accessory page.

Utility requirements for this equipment may vary. Always consult the serving utility for their requirements before ordering or
installing equipment in this catalog.

D4

TEST BLOCK BYPASS—MTB-P & MTB-P48 SERIES—100 AMP—200K AIC
240 & 480 VOLT—SELF CONTAINED METER MAIN / T-FUSE PULLOUT

D5

These UL Listed products are for use in areas requiring
Electrical Utility Service Equipment Requirements Committee
(EUSERC) compliance.

200K Short Circuit Current Withstand Rating

2

1

4

6

3

4

1

214MTB-P
215MTB-P
217MTB-P
214MTB-P48
215MTB-P48
217MTB-P48

2

U214MTB-P
U215MTB-P
U217MTB-P
U214MTB-P48
U215MTB-P48
U217MTB-P48

5 5

4

3

4

6

214MTB-P

SECTION D

5

U217MTB-P

NO.
TYPE
OF
OF
TERM. SERVICE

CATALOG
NUMBER

CONNECTORS
LINE

LOAD
NEUTRAL

TYPE
OF
SERVICE

DIMENSIONS
D"

W"

CONCENTRIC K.O.ʼS

H"

1
1

⁄2

4

OH

214MTB-P*

#1/0-250 #14-1/0 1∅3W *

6

14

48

2

5

OH

215MTB-P

#1/0-250 #14-1/0

6

14

48

21⁄2

14

48

1

18

25

7
4
5
7

OH
OH/UG
OH/UG
OH/UG

217MTB-P
U214MTB-P*
U215MTB-P
U217MTB-P

#1/0-250 #14-1/0

#6-2/0
#6-2/0
#6-2/0

3∅3W
3∅4W

#14-1/0 1∅3W *
#14-1/0
#14-1/0

3∅3W
3∅4W

6
5

4

⁄8

5

4

⁄8

5

4

⁄8

2

⁄2

2

2

3

4

5

6

⁄32

1

⁄32

1

⁄32

1

⁄4

2

⁄4

2

⁄4

2

1

⁄2

3

3

9

21⁄2

3

3

9

2

⁄2

1

3

3

9

2

21⁄2

2

3

1

2

18

25

2

2

2

⁄2

2

3

18

25

2

2

21⁄2

2

3

⁄2
⁄2
⁄2

100 AMP—4, 5, & 7 TERMINAL—480 VOLT—PULL-OUT INSTALLED—RING TYPE
NO.
TYPE
OF
OF
TERM. SERVICE

CATALOG
NUMBER

CONNECTORS
LINE

TYPE
OF
LOAD
NEUTRAL SERVICE

D"

W"

H"

1

2

3

4

DIMENSIONS

CONCENTRIC K.O.ʼS
5

6

⁄32

1

⁄32

1

⁄32

1

⁄4

2

⁄4

2

⁄4

2

4

OH

214MTB-P48*

#6-250

#14-1/0 1∅3W *

6

14

48

21⁄2

21⁄2

3

3

9

5

OH

215MTB-P48

#6-250

#14-1/0

3∅3W

6

14

48

21⁄2

21⁄2

3

3

9

7

OH

217MTB-P48

#6-250

#14-1/0

3∅4W

6

14

48

21⁄2

21⁄2

3

3

9

5

18

25

2

2

21⁄2

2

3

1

4
5
7

OH/UG
OH/UG
OH/UG

U214MTB-P48*
U215MTB-P48
U217MTB-P48

#6-250
#6-250
#6-250

#14-1/0 1∅3W *
#14-1/0
#14-1/0

3∅3W
3∅4W

4

⁄8

5

18

25

2

2

2

⁄2

2

3

5

18

25

2

2

21⁄2

2

3

4
4

⁄8
⁄8

⁄2
⁄2
⁄2

REPLACEMENT MAIN DISCONNECTS: For replacement main disconnect see pages D14 & D15.
* For 3W (208Y/120) network service, install field mounted fifth terminal catalog number 105J. See accessory page.
HUBS: OH units use hub up to 21⁄2" (see accessory page). Units provided with closing plate.
SEALING RINGS: Units furnished with MR-2 snap style sealing rings.
NEUTRAL: “Lay-in” connectors will accommodate #6-2/0 aluminum wire.
PULL-OUTS: For use with T-fuses only. Fuses are included with fused safety sockets.

Utility requirements for this equipment may vary. Always consult the serving utility for their requirements before ordering or
installing equipment in this catalog.

D5

COMMERCIAL METERING–SAFETY SOCKETS, METER MAINS,
TERMINATION BOXES, BUSSED GUTTERS

100 AMP—4, 5, & 7 TERMINAL—240 VOLT—PULL-OUT INSTALLED—RING TYPE

D6

TEST BLOCK BYPASS—MTB SERIES—200 AMP—10K AIC
240 VOLT—SELF CONTAINED METER MAIN / CIRCUIT BREAKER

SECTION D

These UL Listed products
are for use in areas
requiring Electrical Utility
Service Equipment
Requirements Committee
(EUSERC) compliance.

COMMERCIAL METERING–SAFETY SOCKETS, METER MAINS,
TERMINATION BOXES, BUSSED GUTTERS

5

4

6

3

1

2

1

4

224MTB
225MTB
227MTB

5 5

4

4

3

6

2
U224MTB
U225MTB
U227MTB

U227MTB

224MTB

200 AMP—4, 5 & 7 TERMINAL—240 VOLT—BREAKER INSTALLED—RING TYPE
NO.
TYPE
OF
OF
TERM. SERVICE

4

OH

CATALOG
NUMBER
224MTB*

CONNECTORS
LINE
#6-250

LOAD
NEUTRAL

TYPE
OF
SERVICE

#2/0-250 1∅3W *

DIMENSIONS

CONCENTRIC K.O.ʼS

D"

W"

H"

1

2

3

4

6

14

48

21⁄2

21⁄2

3

3

9

1

⁄2

5

6

⁄32

1

⁄32

1

⁄32

1

1

⁄2

3

3

9

21⁄2

3

3

9

1

⁄2

3

1

2

⁄2

3

5

OH

225MTB

#6-250

#2/0-250

3∅3W

6

14

48

2

7

OH

227MTB

#6-250

#2/0-250

3∅4W

6

14

48

21⁄2

30

1

2

30

21⁄2

21⁄2

3

21⁄2

3

30

21⁄2

21⁄2

3

21⁄2

3

4

OH/UG

U224MTB*

#6-250

#2/0-250 1∅3W *

6

22

3

⁄4

5

OH/UG

U225MTB

#6-250

#2/0-250

3∅3W

6

22

3

7

OH/UG

U227MTB

#6-250

#2/0-250

3∅4W

6

22

3

⁄4
⁄4

⁄2

2

2

⁄2
⁄2
⁄2

⁄4

2

⁄2

⁄4

21⁄2

⁄4

21⁄2

1

REPLACEMENT MAIN DISCONNECTS: For replacement main disconnect see pages D14 & D15.
HUBS: OH units use hub up to 21⁄2" (see accessory page). Units provided with closing plate.
SEALING RINGS: Units furnished with MR-2 snap stye sealing rings.
NEUTRAL: “Lay-in” connectors will accommodate #2-250 copper or aluminum wire.
*For 3W (208Y/120) network service, install field mounted fifth terminal catalog number 105J. See accessory page.

Utility requirements for this equipment may vary. Always consult the serving utility for their requirements before ordering or
installing equipment in this catalog.

D6

TEST BLOCK BYPASS—MTB SERIES—200 AMP—22K AIC
240 VOLT—SELF CONTAINED METER MAIN / CIRCUIT BREAKER

D7

These UL Listed products
are for use in areas
requiring Electrical Utility
Service Equipment
Requirements Committee
(EUSERC) compliance.

4

224MTB/22
227MTB/22

5 5

4

4

3

6

2
U224MTB/22
U227MTB/22

U227MTB/22

224MTB/22

200 AMP—4 & 7 TERMINAL—240 VOLT—BREAKER INSTALLED—RING TYPE
NO.
TYPE
OF
OF
TERM. SERVICE

CATALOG
NUMBER

CONNECTORS
LINE

LOAD
NEUTRAL

TYPE
OF
SERVICE

DIMENSIONS
D"

W"

CONCENTRIC K.O.ʼS

H"

1
1

⁄2

4

OH

224MTB/22*

#6-250

#2/0-250 1∅3W *

6

14

48

2

7

OH

227MTB/22

#6-250

#2/0-250

6

14

48

21⁄2

30

1

2

30

21⁄2

4
7

OH/UG U224MTB/22*
OH/UG

U227MTB/22

#6-250
#6-250

3∅4W

#2/0-250 1∅3W *
#2/0-250

3∅4W

6
6

22

3

22

3

⁄4
⁄4

⁄2

2

3

4

5

6

⁄32

1

⁄32

1

1

⁄2

3

3

9

21⁄2

3

3

9

1

⁄2

3

1

2

⁄2

3

21⁄2

3

21⁄2

3

2

2

⁄2
⁄2

⁄4

2

⁄2

⁄4

21⁄2

1

REPLACEMENT MAIN DISCONNECTS: For replacement main disconnect see pages D14 & D15.
HUBS: OH units use hub up to 21⁄2" (see accessory page). Units provided with closing plate.
SEALING RINGS: Units furnished with MR-2 snap stye sealing rings.
NEUTRAL: “Lay-in” connectors will accommodate #2-250 copper or aluminum wire.
*For 3W (208Y/120) network service, install field mounted fifth terminal catalog number 105J. See accessory page.

Utility requirements for this equipment may vary. Always consult the serving utility for their requirements before ordering or
installing equipment in this catalog.

D7

COMMERCIAL METERING–SAFETY SOCKETS, METER MAINS,
TERMINATION BOXES, BUSSED GUTTERS

6

3

SECTION D

5

4

1

2

1

D8

TEST BLOCK BYPASS—MTB SERIES—200 AMP—35K AIC
480 VOLT—SELF CONTAINED METER MAIN / CIRCUIT BREAKER
These UL Listed products are for use in areas requiring
Electrical Utility Service Equipment Requirements
Committee (EUSERC) compliance.

COMMERCIAL METERING–SAFETY SOCKETS, METER MAINS,
TERMINATION BOXES, BUSSED GUTTERS

SECTION D

35K Short Circuit Current Withstand Rating

2

1
5

4

6

3

4

224MTB-48
227MTB-48

1

2

U227MTB-48

227MTB-48

5 5

4

3

4

6

U224MTB-48
U227MTB-48

200 AMP—4 & 7 TERMINAL—480 VOLT—BREAKER INSTALLED—RING TYPE
NO.
TYPE
OF
OF
TERM. SERVICE

7

OH

CATALOG
NUMBER
227MTB-48

CONNECTORS
LINE
#6-250

LOAD
NEUTRAL

#2/0-250

TYPE
OF
SERVICE

3∅4W

DIMENSIONS
D"
6

W"
14

4

OH/UG U224MTB-48*

#6-250

#2/0-250 1∅3W *

6

22

3

7

OH/UG

#6-250

#2/0-250

6

22

3

U227MTB-48

3∅4W

⁄4
⁄4

CONCENTRIC K.O.ʼS

H"

1

48

1

2

30
30

⁄2

2

3

4

5

6

⁄32

1

1

⁄2

3

3

9

21⁄2

21⁄2

3

21⁄2

3

21⁄2

21⁄2

3

21⁄2

3

2

⁄2

⁄4

21⁄2

⁄4

21⁄2

REPLACEMENT MAIN DISCONNECTS: For replacement main disconnect see pages D14 & D15.
HUBS: OH units use hub up to 21⁄2" (see accessory page). Units provided with closing plate.
SEALING RINGS: Units furnished with MR-2 snap style sealing rings.
NEUTRAL: “Lay-in” connectors will accommodate #2-250 copper or aluminum wire.
* For 3W (208Y/120) network service, install field mounted fifth terminal catalog number 105J. See accessory page.

Utility requirements for this equipment may vary. Always consult the serving utility for their requirements before ordering or
installing equipment in this catalog.

D8

TEST BLOCK BYPASS—MTB-P SERIES & MTB-P48 SERIES—200 AMP—200K AIC
240/480 VOLT—SELF-CONTAINED METER MAIN / T-FUSE PULLOUT

D9

These UL Listed products are for use in areas requiring
Electrical Utility Service Equipment Requirements Committee
(EUSERC) compliance.

200K Short Circuit Current Withstand Rating

5

4

1
6

3

2

5 5

4

4
224MTB-P
225MTB-P
227MTB-P
224MTB-P48
225MTB-P48
227MTB-P48

4

3

6

U224MTB-P
U227MTB-P
U224MTB-P48
U227MTB-P48

U227MTB-P

200 AMP—4, 5 & 7 TERMINAL—240 VOLT PULLOUT INSTALLED—RING TYPE
NO.
TYPE
OF
OF
TERM. SERVICE

CATALOG
NUMBER

CONNECTORS
LINE

TYPE

OF
LOAD
NEUTRAL SERVICE

DIMENSIONS

CONCENTRIC K.O.ʼS

D"

W"

H"

1

2

3

4

5

6

⁄32

1

⁄32

1

⁄32

1

⁄4

2

⁄4

2

4

OH

224MTB-P*

#6-250 #1/0-250 1∅3W *

6

14

48

21⁄2

21⁄2

3

3

9

5

OH

225MTB-P

#6-250 #1/0-250

3∅3W

6

14

48

21⁄2

21⁄2

3

3

9

7

OH

227MTB-P

#6-250 #1/0-250

3∅4W

6

14

48

21⁄2

21⁄2

3

3

9

4

OH/UG

U224MTB-P*

30

2

2

21⁄2

2

3

30

2

2

21⁄2

2

3

7

OH/UG

U227MTB-P

#6-250 #1/0-250 1∅3W *
#6-250 #1/0-250

3∅4W

6
6

22

3

22

3

⁄4
⁄4

⁄2
⁄2
⁄2

200 AMP—4, 5 & 7 TERMINAL—200 AMP-480 VOLT PULLOUT INSTALLED —RING TYPE
NO.
TYPE
OF
OF
TERM. SERVICE

CATALOG
NUMBER

CONNECTORS
LINE

TYPE

OF
LOAD
NEUTRAL SERVICE

DIMENSIONS

CONCENTRIC K.O.ʼS

D"

W"

H"

1

2

3

4

5

6

⁄32

1

⁄32

1

⁄32

1

⁄4

2

⁄4

2

4

OH

224MTB-P48* #6-250 #1/0-250 1∅3W *

6

14

48

21⁄2

21⁄2

3

3

9

5

OH

225MTB-P48

#6-250 #1/0-250

3∅3W

6

14

48

21⁄2

21⁄2

3

3

9

7

OH

227MTB-P48

#6-250 #1/0-250

3∅4W

6

14

48

21⁄2

21⁄2

3

3

9

30

2

2

21⁄2

2

3

30

2

2

21⁄2

2

3

4

OH/UG U224MTB-P48*

#6-250 #1/0-250 1∅3W *

6

22

3

7

OH/UG

#6-250 #1/0-250

6

22

3

U227MTB-P48

3∅4W

⁄4
⁄4

⁄2
⁄2
⁄2

REPLACEMENT MAIN DISCONNECTS: For replacement main disconnect see pages D14 & D15.
HUBS: OH units use hub up to 21⁄2" (see accessory page). Units provided with closing plate.
SEALING RINGS: Units furnished with MR-2 snap style sealing rings.
NEUTRAL: “Lay-in” connectors will accommodate #2-250 copper or aluminum wire.
PULL-OUTS: For use with T-fuses only. Fuses are included with fused safety sockets.
* For 3W (208Y/120) network service, install field mounted fifth terminal catalog number 105J. See accessory page.

Utility requirements for this equipment may vary. Always consult the serving utility for their requirements before ordering or
installing equipment in this catalog.

D9

COMMERCIAL METERING–SAFETY SOCKETS, METER MAINS,
TERMINATION BOXES, BUSSED GUTTERS

224MTB-P

SECTION D

2

1

D10

TEST BLOCK BYPASS—MTBL ALL-IN-ONE SERIES—100 & 200 AMP—10K & 200K AIC
240 VOLT METER MAIN—CIRCUIT BREAKER / T-FUSE PULLOUT
These UL Listed products are for use in areas requiring
Electrical Utility Service Equipment Requirements
Committee (EUSERC) compliance.

25" or
27"

ON OFF

COMMERCIAL METERING–SAFETY SOCKETS, METER MAINS,
TERMINATION BOXES, BUSSED GUTTERS

SECTION D

24 3/4"
or
30"

4 5/8"
or
6"

U227-MTBL

CATALOG
NUMBER
U214MTBL

RATING

NO.
MAIN CIRCUIT BREAKER
INTERNAL
OR
CIRCUITS

100A,120/240 12/24
VAC 1∅3W

100A,120/240 12/24
U214MTBPL
VAC 1∅3W

U217MTBL

U217MTBPL
U224MTBL

100A,
240Δ/120;
208Y/120 VAC
3∅4W
100A,
240Δ/120;
208Y/120 VAC
3∅4W

U227MTBPL

D"

W"

100A, 2P, 10K
Milbank Q2100

45⁄8

25

243⁄4

100A, 2P, 100K
Boltswitch PT223

45⁄8

UTILITY SECTION

(1) 1/2"
(3) 11/4",11/2",2",21/2"
25

243⁄4

100A, 3P, 10K
Siemens BQ3100

45⁄8

25

243⁄4

18/36

100A, 3P, 100K
Boltswitch PT323

45⁄8

25

243⁄4

200A, 2P, 10K
Milbank UQFP-200

6

27

30

200A, 2P, 100K
Boltswitch PT224

6

200A,120/240 20/40
U224MTBPL
VAC 1∅3W

U227MTBL

FUSE PULLOUT

BOTTOM
BACK
CONDUIT
K.O.ʼS
CONDUIT
K.O.ʼS
H"

18/36

200A,120/240 20/40
VAC 1∅3W

200A,
240Δ/120;
208Y/120 VAC
3∅4W
200A,
240Δ/120;
208Y/120 VAC
3∅4W

DIMENSIONS

24/42

24/42

CUSTOMER
SECTION

(3) 1/2", 3/4"
(1) 1/2" ,3/4" ,1",11/4"
(2) 3/4",1",11/4",11/2"

CUSTOMER
SECTION

(7) 1/2"
(4) 1/2" , 3/4"
3
(1) /4" ,1",11/4",11/2"

UTILITY SECTION

200A, 3P, 10K
Siemens QJ23B200

6

200A, 3P, 100K
Boltswitch PT324

6

27

27

27

30

30

30

(1) 1/2", 3/4"
(2) 11/4",11/2", 2",21/2"
(1) 21/2" ,3"
CUSTOMER
SECTION

(11) 1/2"
(2) 1/2", 3/4"
(1) 1/2" ,3/4",1",11/4"
(2) 3/4",1",11/4",11/2"

CUSTOMER
SECTION

(6) 1/2"
(4) 1/2" , 3/4"
3
(1) /4" ,1",11/4",11/2"

LINE: Underground or overhead service. Line Lug: 100A, 14-2/0 and 200A 1/0-250
LOAD: Underground only.
BRANCH BREAKERS: Single phase units—approved for Siemens/ITE Type Q, Challenger, Cutler-Hammer/Westinghouse,
General Electric, Murray. Three phase units—approved for Siemens/ITE Type Q.
HUBS: OH units use hub up to 21⁄2" (see accessory page). Units provided with closing plate.
PULL-OUTS: For use with T-fuses only. Fuses are included with fused safety sockets.

 For 208Y/120 applications, order separately and field install kit 105J.
Utility requirements for this equipment may vary. Always consult the serving utility for their requirements before ordering or
installing equipment in this catalog.

D10

UNDERGROUND TERMINATION BOXES—600 VAC

D11

These UL Listed products are for use in areas requiring
Electrical Utility Service Equipment Requirements
Committee (EUSERC) compliance.

SECTION D

PB-011

PB-032

PB-012
PB-038

X- dim.
PB-011
1 1/4"

1 1/4"

1 1/4" 1 1/4"

PB-012

PB-032

UNDERGROUND TERMINATION BOXES
AMPS

TYPE
CATALOG
OF
NUMBER
SERVICE

LINE

LOAD

D"

W"

H"

X"

SHORT CIRCUIT
CURRENT
WITHSTAND RATING

CONNECTORS

DIMENSIONS

100

1∅-3W

PB-011

#14-1/0

#14-1/0

4

12

81⁄2

33⁄4

10K AMPS

200

1∅-3W

PB-012

#6-250

#6-250

6

12

26

141⁄4

10K AMPS

400

1∅-3W

1/2"-13
studs

twin 1⁄0-250

6

16

36

22

50K AMPS

800

1∅-3W

PB-014
PB-014-NK
PB-018
PB-018-NK

1/2"-13
studs 

twin 1⁄0-250

11

24

48

26

50K AMPS

200

3∅-4W

PB-032

#6-250

#6-250

6

16

26

1411⁄16

10K AMPS

400

3∅-4W

PB-034
PB-034-NK

1/2"-13
studs 

twin 1⁄0-250

6

16

36

22

50K AMPS

800

3∅-4W

PB-038

1/2"-13
studs 

twin 1⁄0-250

11

24

48

26

50K AMPS *

#4-600
#4-600

#4-600
#4-600

CONNECTORS AND BUSSING: Extruded aluminum connectors and bus bars are tin plated.
For no knockouts, add suffix -NK to the above catalog numbers.
 No lift handles provided on the PB-011.
 2 studs per lug position provided for 400 amp units. 4 studs per lug position provided for 800 amp units.

Utility requirements for this equipment may vary. Always consult the serving utility for their requirements before ordering or
installing equipment in this catalog.

D11

COMMERCIAL METERING–SAFETY SOCKETS, METER MAINS,
TERMINATION BOXES, BUSSED GUTTERS

X-dim.
X-dim.

D12

BUSSED GUTTERS—TYPE 3R—1∅3W AND 3∅4W—600 VAC

COMMERCIAL METERING–SAFETY SOCKETS, METER MAINS,
TERMINATION BOXES, BUSSED GUTTERS

SECTION D

These UL Listed products
are for use in areas
requiring Electrical Utility
Service Equipment
Requirements Committee
(EUSERC) compliance.

BC418

FOR COMMERCIAL SAFETY SOCKET APPLICATIONS

1∅3W—BUSSED GUTTERS—TYPE 3R—600 VAC
DIMENSIONS

METER
POSITION

CATALOG
NUMBER

AMPERE
RATING

D"

2

BC214

400

6

3

BC318

800

6

4

BC418

800

5

BC518

6

BC618

W"

H"

LENGTH
OF
BUS

LINE LUGS
PER
EACH BUS

LOAD LUGS
PER
EACH BUS

20" Bar

(1) 600

(2) 6-250

28 ⁄8 151⁄2
5

151⁄2

(2)

20" Bars

(2) 600

(3) 6-250

6

57 ⁄4 15 ⁄2

(2)

20" Bars

(2) 600

(4) 6-250

800

6

715⁄8 151⁄2

(2)

20" Bars

(2) 600

(5) 6-250

800

6

85 ⁄8 15 ⁄2

(2)

20" Bars

(2) 600

(6) 6-250

LENGTH
OF
BUS

LINE LUGS
PER
EACH BUS

LOAD LUGS
PER
EACH BUS

20" Bar

(1) 600

(2) 6-250

43
1

7

1

1

3∅4W—BUSSED GUTTERS—TYPE 3R—600 VAC
DIMENSIONS

METER
POSITION

CATALOG
NUMBER

AMPERE
RATING

D"

2

BC234

400

6

3

BC338

800

6

4

BC438

800

5

BC538

6

BC638

W"

H"

285⁄8 151⁄2
15 ⁄2

(2)

20" Bars

(2) 600

(3) 6-250

6

571⁄4 151⁄2

(2)

20" Bars

(2) 600

(4) 6-250

800

6

71 ⁄8 15 ⁄2

(2)

20" Bars

(2) 600

(5) 6-250

800

6

857⁄8 151⁄2

(2)

20" Bars

(2) 600

(6) 6-250

43

5

1

1

SHORT CIRCUIT CURRENT WITHSTAND RATING: Standard bracing is 42K AIC.
CONNECTORS AND BUSSING: Extruded aluminum connectors and bus bars are tin plated.
COVER: Lift handles provided along with a cover sealing provision. A removable, sealable
cover is provided at both ends for pull box assembly.
HARDWARE: Meter socket mounting hardware included.
SUITABLE FOR USE ON LINE SIDE OF SERVICE EQUIPMENT.

Utility requirements for this equipment may vary. Always consult the serving utility for their requirements before ordering or
installing equipment in this catalog.

D12

BUSSED GUTTERS—TYPE 3R—3∅4W—600 VAC

D13

These UL Listed products
are for use in areas
requiring Electrical Utility
Service Equipment
Requirements Committee
(EUSERC) compliance.

•
•
•
•

3∅4W—BUSSED GUTTERS—TYPE 3R—600 VAC
LINE LUGS
PER
EACH BUS

24

24

17" Bar

(1) 600

6

36

24

24" Bars

(2) 600

800

6

48

24

32" Bars

(3) 600

U3465-O

800

6

60

24

40" Bars

(3) 600

U3466-O

800

6

72

24

56" Bars

(3) 600

CATALOG
NUMBER

AMPERE
RATING

D"

W"

2

U3462-O

400

6

3

U3463-O

600

4

U3464-O

5
6

SHORT CIRCUIT CURRENT WITHSTAND RATING: The 400 and 600 amp units have a
withstand rating of 50K amps, and the 800 amp units have a rating of 65K amps.
SUITABLE FOR USE ON LINE SIDE OF SERVICE EQUIPMENT.
Gasket attached
to Pull Box

Bussed Gutter

Knockouts

Pull Box

Meter Socket

Typical Application of
Safety Sockets
with Multi-Metering
(shown with KOs)

Utility requirements for this equipment may vary. Always consult the serving utility for their requirements before ordering or
installing equipment in this catalog.

D13

COMMERCIAL METERING–SAFETY SOCKETS, METER MAINS,
TERMINATION BOXES, BUSSED GUTTERS

H"

LENGTH
OF
BUS

DIMENSIONS

METER
POSITION

SECTION D

Enclosure without knockouts
Tin plated aluminum bus bars
Furnished with line lugs only
Bus is drilled and tapped for easy
installation of load lugs

D14

SAFETY SOCKET REPLACEMENT CIRCUIT BREAKERS & PULLOUTS

COMMERCIAL METERING–SAFETY SOCKETS, METER MAINS,
TERMINATION BOXES, BUSSED GUTTERS

SECTION D

REPLACEMENT CIRCUIT BREAKERS

REPLACEMENT CIRCUIT BREAKERS, cont.

CATALOG
NUMBER

CIRCUIT
BREAKER

MFG.

PART
NUMBER

CATALOG
NUMBER

CIRCUIT
BREAKER

MFG.

PART
NUMBER

214MTB

BQ2B100L

Milbank

917930-MO

227MTB

UQFB-3200

Milbank

916777-MO

214MTB-48

ED42B100

Siemens

705831-MO

227MTB-125

UQFB-3125

Milbank

916759-MO

214MTB/22

BQ2B100HL

Milbank

917960-MO

227MTB-150

UQFB-3150

Milbank

916765-MO

U214MTB

BQ2B100L

Milbank

917930-MO

227MTB-175

UQFB-3175

Milbank

926772-MO

U214MTB-48

ED42B100

Siemens

705831-MO

227MTB-48

FXD63B200

Siemens

706036-MO

U214MTB/22

BQ2B100HL

Milbank

917960-MO

227MTB/22

QJH23B200L

Siemens

707503-MO

U214MTBL

BQ2B100L

Milbank

917915-MO

227MTB

UQFB-3200

Milbank

916777-MO

U227MTB-125

UQFB-3125

Milbank

916759-MO

215MTB

BQ3B100L

Milbank

917990-MO

U227MTB-150

UQFB-3150

Milbank

916765-MO

215MTB-48

ED43B100

Siemens

708571-MO

U227MTB-175

UQFB-3175

Milbank

926772-MO

U215MTB

BQ3B100L

Milbank

917990-MO

U227MTB-48

FXD63B200

Siemens

706036-MO

U215MTB-48

ED43B100

Siemens

708571-MO

U227MTB/22

QJH23B200L

Siemens

707503-MO

U227MTBL

QJ23B200

Siemens

707403-MO

217MTB

BQ3B100L

Milbank

917990-MO

217MTB-48

ED43B100

Siemens

708571-MO

217MTB/22

BQ3B100HL

Milbank

918020-MO

U217MTB

BQ3B100L

Milbank

917990-MO

U217MTB-48

ED43B100

Siemens

708571-MO

U217MTB/22

BQ3B100HL

Milbank

918020-MO

U217MTBL

BQ3B100L

Milbank

917990-MO

SIEMENS
CIRCUIT
BREAKER

NUMBER OF
LUG COLLARS
REQUIRED

PART NUMBER

224MTB

UQFB-200

Milbank

915548-MO

ED42B100

(2) LN13100

705831-MO

224MTB/22

UQFBH-200

Milbank

915748-MO

ED43B100

(3) LN1E100

708572-AC

U224MTB

UQFB-200

Milbank

915548-MO

FXD62B200

(4) TA1FD350

708573-AC

U224MTB-48

FXD62B200

Siemens

705747-MO

FXD63B200

(6) TA1FD350

706036-MO

U224MTB/22

UQFBH-200

Milbank

915748-MO

QJ22B200H

(2) TA1Q300

707523-MO

U224MTBL

UQFB-200

Milbank

915548-MO

QJ23B200

(1) TA1Q300

707403-MO

QJH23B200L

(1) TA1Q300

707503-MO

U225MTB

UQFB-3200

Milbank

916777-MO

U225MTBL

QJ23B200

Siemens

707403-MO

LUG KITS FOR CIRCUIT BREAKERS

When replacing Siemens Circuit Breaker (FXD,ED,QJ) in
safety sockets, lug collars must be ordered separately.

D14

SAFETY SOCKET REPLACEMENT CIRCUIT BREAKERS & PULLOUTS D15

REPLACEMENT T-FUSE PULLOUTS

LUG KITS FOR T-FUSE PULLOUTS

MFG.

PART
NUMBER

T-FUSE
PULLOUTS

NUMBER OF
LUG COLLARS
REQUIRED

PART NUMBER

214MTB-P

PT223

Boltswitch

707674-MO

PT223

(2) TK100P

707682-AC

214MTB-P48

PT263

Boltswitch

708564-MO

PT224

(2) TK200P

708570-AC

U214MTB-P

PT223

Boltswitch

707674-MO

PT263

(2) TK100P

707682-AC

U214MTB-P48

PT263

Boltswitch

708564-MO

PT264

(2) TK200P

708570-AC

U214MTBPL

PT223

Boltswitch

707674-MO

PT323

(3) TK100P

707682-AC

215MTB-P

PT323

Boltswitch

708565-MO

PT324

(3) TK200P

708570-AC

215MTB-P48

PT363

Boltswitch

708566-MO

PT363

(3) TK100P

707682-AC

U215MTB-P

PT323

Boltswitch

708565-MO

PT364

(3) TK200P

708570-AC

U215MTB-P48

PT363

Boltswitch

708566-MO

217MTB-P

PT323

Boltswitch

708565-MO

217MTB-P48

PT363

Boltswitch

708566-MO

U217MTB-P

PT323

Boltswitch

708565-MO

U217MTB-P48

PT363

Boltswitch

708566-MO

U217MTBPL

PT323

Boltswitch

708565-MO

224MTB-P

PT224

Boltswitch

707684-MO

224MTB-P48

PT264

Boltswitch

708567-MO

U224MTB-P

PT224

Boltswitch

707684-MO

U224MTB-P48

PT264

Boltswitch

708567-MO

U224MTBPL

PT224

Boltswitch

707684-MO

225MTB-P48

PT364

Boltswitch

708569-MO

U225MTBPL

PT324

Boltswitch

708568-MO

227MTB-P

PT324

Boltswitch

708568-MO

227MTB-P48

PT364

Boltswitch

708569-MO

U227MTB-P

PT324

Boltswitch

708568-MO

U227MTB-P48

PT364

Boltswitch

708569-MO

U227MTBPL

PT324

Boltswitch

708568-MO

D15

NOTE: T-Fuse pullouts provided with load side lugs.
Order line side lugs separately from above chart.

COMMERCIAL METERING–SAFETY SOCKETS, METER MAINS,
TERMINATION BOXES, BUSSED GUTTERS

T-FUSE
PULLOUT

SECTION D

CATALOG
NUMBER

D16

SAFETY SOCKET & T-FUSE REPLACEMENT PARTS

COMMERCIAL METERING–SAFETY SOCKETS, METER MAINS,
TERMINATION BOXES, BUSSED GUTTERS

SECTION D

These UL Listed products
are for use in areas
requiring Electrical Utility
Service Equipment
Requirements Committee
(EUSERC) compliance.

TB200-47

MS-27-TB

TENANT METER SOCKETS

REPLACEMENT TEST BLOCKS

AMPS

CATALOG
NUMBER

VOLTAGE / SYSTEM

AMPS

CATALOG
NUMBER

PHASE

200

MS-24-TB

600V / 1∅3W

100

TB100-47

PHASE A, B & C

200

MS-27-TB

600V / 3∅4W

100

TB100-5
CENTER BLOCK ONLY

PHASE B—3∅3W

200

TB200-47

PHASE A, B & C

200

TB200-5
CENTER BLOCK ONLY

PHASE B—3∅3W

200

TB200-LL

LUG—LUG

—

TB-BARR
#Z707371-MO

TEST BLOCK BARRIER

PT324

240 VOLT
MAIN DISCONNECTS
PULLOUT SWITCH
(USES TYPE “T” FUSE)

480 VOLT
MAIN DISCONNECTS
PULLOUT SWITCH
(USES TYPE “T” FUSE)

AMPS

CATALOG
NUMBER

RATING

AMPS

CATALOG
NUMBER

RATING

100

PT223

2 POLE—240 VOLT

100

PT263

2 POLE, 480 VOLT

200

PT224

2 POLE—240 VOLT

200

PT264

2 POLE, 480 VOLT

100

PT323

3 POLE—240 VOLT

100

PT363

3 POLE, 480 VOLT

200

PT324

3 POLE—240 VOLT

200

PT364

3 POLE, 480 VOLT

Utility requirements for this equipment may vary. Always consult the serving utility for their requirements before ordering or
installing equipment in this catalog.

D16

OVERVIEW

E1

Commercial Pedestals
• Attractive

Un-Strut
Your
Stuff...

• Easy to install

• Secure

• Cost effective

Commercial Pedestal

UL Listed as Industrial Control Equipment (File E113855).
STANDARD FEATURES –COMMERCIAL PEDESTALS

Ringless Socket

Ring-type Socket

Utility Lug Landing

Customer Interior

• Type 3R rainproof, vandal-resistant cabinet of
polyurethane powder-coated steel (aluminum or
stainless steel also available)
• UL listed as enclosed industrial control
equipment (UL508)
• Isolated, lockable & sealable utility metering &
lug landing sections
• Lockable customer section for distribution &
control equipment with internal deadfront
• Print pocket inside customer section door
contains wiring schematics
and installation instructions
• Most load centers are UL
listed for use with various
manufacturers’ circuit
breakers
• All stainless steel external
hardware (screws, bolts,
hinges, handles, hasps and
sealing screws)
• Meets EUSERC 308 and other
utility standards.

Utility requirements for this equipment may vary. Always consult the serving utility for their requirements before ordering or
installing equipment in this catalog.

E1

COMMERCIAL METER PEDESTALS

Strut and backboard design

SECTION E

ilbank Commercial Pedestals are pad-mounted, weatherproof electrical
enclosures consisting of a utility pull section with optional meter socket, and
a customer section containing distribution and control equipment. Milbank
Commercial Pedestals
are an attractive, secure,
easy to install and costeffective solution when
underground remote
site power distribution
and control equipment
is required, replacing
unsightly and inefficient
strut and backboard
structures.

E2

APPLICATIONS & ACCESSORIES

APPLICATIONS
These units are ideal for controlling and metering:
• Traffic signals
• Street lighting
• Irrigation / sprinkler systems
• Cell towers / telephone vaults
• Pump stations
• Temporary power for fairgrounds, swap meets, outdoor
markets, portable offices, holiday lights, etc.
• Outdoor lighting for athletic fields, tennis and basketball courts, parking lots,
landscaping and subdivision entrances, etc.

COMMERCIAL METER PEDESTALS

SECTION E

AVAILABLE FACTORY-INSTALLED OPTIONS
• Meter sockets – ring type or ringless, to 400 amp (unmetered
pedestals also available)
• Main and branch breakers or T fuses
• Distribution – copper load centers & panel boards
• Clocks / timers / relays
• Photoelectric cells and controls
• Power receptacles – pin & sleeve, twist lock or straight blade
• Contactors – definite purpose, electrical or mechanically
held, IEC and mercury types
• Surge protection & lightning arrestors
• Reserve inlet generator receptacle with interlocked circuit
breakers

• Motor starters, relays
• Push button controls
• Thermostat controls, fans and heating strips
• Power blocks and terminal blocks
• Steel, aluminum and plywood back boards
• Transformers
• Interlock devices for circuit breakers
• Available in steel, aluminum (raw painted or anodized) or
stainless steel construction with powder-coated finish
available in 8 standard colors or special ordered RAL colors.
• Available for applications up to 400 amp, 120V, 208V,
240V, 277V, 480V – 1Ø or 3Ø.

ACCESSORIES

105J
Fifth terminal
kit for use
with ring-type
meter sockets

CP-TC7D 7-day time clock kit
CP-TC24H 24-hour time clock kit
CP-TCWIRE Male four-pin connector
and wiring harness for use
with time clocks other than
shown

K3865
Fifth terminal kit for
use with ringless
meter sockets

CP-ABK5/8
Anchor bolt kit (includes four 5/8 13 x 18" anchor bolts)

CP-16PDMNT-CALT
Pedestal mounting base for 16" pedestal
CP-24PDMNT-CALT
Pedestal mounting base for 24" pedestal
(includes mounting hardware)

CP-PE-HOA-3POS
HOA switch – for field
installation

Utility requirements for this equipment may vary. Always consult the serving utility for their requirements before ordering or
installing equipment in this catalog.

E2

CATALOG NUMBER LOGIC

E3

SECTION E
COMMERCIAL METER PEDESTALS

Logic description subject to change and factory interpretation.
E3

E4

ML SERIES–MAIN LOAD CENTER

CP3B “ML” Series

Features:
These units include everything required for
remote site service:

Main Load Center Series
1∅ 3 wire 120/240 or 208Y/120 volt

 NEMA 3R construction

Typical applications: Remote site service
for multiple loads

 Expandable – Load centers allow for future
expansion without costly modifications

The Milbank Main Load Center Commercial
Pedestals are designed to handle the vast majority of
all requirements in a standard, stocked configuration.

 All units feature 200 amp meter socket with
optional field-installable fifth terminal kit
available

• No waiting or extra charge

 22K ampere interrupting capacity (AIC)

COMMERCIAL METER PEDESTALS

SECTION E

• Units all feature a load center with a plugon, back-fed main breaker.

standard

 Optional mounting base can be embedded in

• Load center has 16 positions for the
100 amp pedestals and 24 circuits for
the 200 amp pedestals.

concrete for fast, easy installation

 Separate sealable and lockable utility

• Both sizes include sub-feed lugs to
allow feeding an external panel

termination section

 Separate sealable and lockable metering

If your application requires
turning loads on based on “dusk-todawn” requirements, be sure to see
the Milbank Switched Load Center
Commercial Pedestal
products on the
following page.

section with the option of:
EITHER
	

Milbank ring-type socket with test / bypass
blocks (conforms to EUSERC 308)
OR

	

Milbank heavy duty ringless socket with
lever bypass

 A separate sealable and lockable customer
section with a load center for “always on”
loads that includes:
• Main circuit breaker
• Twenty (200 or 125 amp model) or
fourteen (100 amp model) blank breaker
spaces
• A circuit directory to document
configuration
STOCKED
PEDESTALS*

OPTIONAL FIFTH
TERMINAL KIT

MAIN CB
LOAD CENTER
AMPS
SPACES
CIRCUITS

AIC

METER SOCKET TYPE

CP3B11115A22

105J

100

1,2

16

22K

Ring-type with test / bypass blocks

CP3B11115A42

105J

100

1,2

16

42K

Ring-type with test / bypass blocks

CP3B12119A22

105J

200

1,2,3,4

24

22K

Ring-type with test / bypass blocks

CP3B51115A22

K3865

100

1,2

16

22K

Ringless socket with lever bypass

CP3B52119A22

K3865

200

1,2,3,4

24

22K

Ringless socket with lever bypass

*NOTE: Chart shows standard, stocked items. Other options and features are available. Contact factory for options details and
availability.

Utility requirements for this equipment may vary. Always consult the serving utility for their requirements before ordering or
installing equipment in this catalog.

E4

SL SERIES–SWITCHED LOAD CENTER

CP3B “SL” Series

Features:
These units include everything required for remote service:

Switched Load Center Series
1∅ 3 wire 120/240 or 208Y/120 volt

 NEMA 3R construction
 Expandable – Load centers allow for future expansion

Typical applications: Traffic signal, parking
lot, highway, & athletic field lighting

 All units feature 200 amp meter socket with optional

The Milbank Switched Load Center Commercial
Pedestals are designed to not only provide power for
various loads, but also to switch specific loads on and
off under certain conditions. A photoelectric cell is
used for these controlled loads, and an optional time
clock is also available.

E5

without costly modifications

field-installable fifth terminal kit available

 22K ampere interrupting capacity (AIC) standard
 Optional mounting base can be embedded in concrete
for fast, easy installation

 Separate sealable and lockable utility termination section
 Separate sealable and lockable metering section with the
option of:

EITHER
Milbank ring-type socket with test / bypass blocks
(conforms to EUSERC 308)
OR
	

Milbank heavy duty ringless socket with lever bypass

 A separate sealable and lockable customer section with:
Control circuit including:
• PE receptacle, Lexan® window and glare shield
• Hand-Off-Auto (HOA) switch
• Contactor controlling a 16-circuit load center for
controlled loads
• Pre-mounted DIN rail and pre-wired connector to
add an optional “plug and play” time clock kit for PE
on and TC off operation
• A circuit directory to document configuration
	

A load center for “always on” loads that includes:
• Main circuit breaker
• Control power circuit breaker
• Switched load center main breaker
• Nine (200 amp model) or eleven (100 amp model)
blank breaker spaces
• A circuit directory to document configuration

STOCKED
PEDESTALS*

OPTIONAL FIFTH
TERMINAL KIT

MAIN CB
AMPS
SPACES

CONTACTOR
AMPERAGE

METER SOCKET TYPE

CP3B11110A22SL1

105J

100

(1,3)

60

Ring-type with test / bypass blocks

CP3B12110A22SL1

105J

200

(1,2,3,4)

100

Ring-type with test / bypass blocks

CP3B51110A22SL1

K3865

100

(1,3)

60

Ringless socket with lever bypass

CP3B52110A22SL1

K3865

200

(1,2,3,4)

100

Ringless socket with lever bypass

*NOTE: Chart shows standard, stocked items. Other options and features are available. Contact factory for options details and
availability.

Utility requirements for this equipment may vary. Always consult the serving utility for their requirements before ordering or
installing equipment in this catalog.

E5

COMMERCIAL METER PEDESTALS

	

SECTION E

	

E6

400 AMP SERIES

Features:

CP3B “400” Series

These units include everything required for
remote site service:

400 amp Series
1∅ 3 wire 120/240 or 208Y/120 volt

 NEMA 3R construction
 Main circuit breaker or dual service

Typical applications: Remote site service for
residential and commercial jobsites

disconnects

The Milbank 400 amp Commercial Pedestal is designed
to provide a weather and vandal resistant metered enclosure
for various loads and distribution. Each pedestal has been
designed to handle a wide range of applications using
standard, stocked configurations.

COMMERCIAL METER PEDESTALS

SECTION E

• Choice of a single main breaker or twin service disconnect
breakers gives flexibility to the pedestal design.

 Expandable – Load center units allow for
future expansion without costly modifications

 22K ampere interrupting capacity (AIC)
standard

 Optional mounting base can be embedded in
concrete for fast, easy installation

 Separate sealable and lockable utility

• Optional distribution with feedthru lugs below the service
disconnect breakers allows the
pedestal to handle numerous
applications.

termination section with lug termination

 Separate sealable and lockable metering
section

 A separate sealable and lockable customer

•Typical applications include
remote homes where the
metering is best located at the
curb side or other remote area.
The pedestal can also provide
power to secondary residence,
on-site business, workshop,
irrigation, lighting, security or
other secondary load.

section with a circuit directory and a print
pocket to hold all documentation

Meter Socket Options:
• Ring type with bypass studs
• Ringless with heavy duty lever bypass
• K type bolt-on

• Available in custom c o l o r s t o
m a t c h home or landscaping.
STOCKED
PEDESTALS*

OPTIONAL FIFTH
TERMINAL KIT

CP3B1411JB22

N/A

CP3B14120B22

N/A

CP3B5411JB22

K3865

MAIN CB
320 amp (400 max)
2-200 amp
320 amp (400 max)

LOAD CENTER
CIRCUITS

AIC

0

22K

Ring type with test / bypass studs

(2) 12 ckt 

22K

Ring type with test / bypass studs

0

22K

Ringless with lever bypass

22K

Ringless with lever bypass

METER SOCKET TYPE

CP3B54120B22

K3865

2-200 amp

(2) 12 ckt 

CP3B8411JB22



400 amp

0

22K

K4 Bolt-on

CP3B84120B22



2-200 amp

(2) 12 ckt 

22K

K4 Bolt-on

*NOTE: Chart shows standard, stocked items. Other options and features are available. Contact factory for options details and
availability.
Stud utility landing is standard. Lug kits are available from factory.
 Units with load centers have (2) #6-250 sub-feed lugs on each load center. (Each load center is 200 amp rated and UL Listed
with: Siemens, General Electric and Cutler-Hammer plug-in style circuit breakers.)
 When ordering, specify lugs or studs for utility landings.
Three phase units available — contact factory.

Utility requirements for this equipment may vary. Always consult the serving utility for their requirements before ordering or
installing equipment in this catalog.

E6

IR SERIES–IRRIGATION CONTROL

Features:

CP3B “IR” Series

These units include everything required for
remote site service:

Irrigation Control Pedestals
1∅ 3 wire 120/240 or 208Y/120 volt

 NEMA 3R construction

Typical application: Metered Power Pedestal for
Irrigation Systems

 2 each 20 amp single pole circuit breakers:
one breaker for standard 20 amp GFCI
receptacle and one breaker for irrigation
control circuit

 Large plywood back panel for mounting
irrigation controller

 All units feature 200 amp meter socket
with optional field-installable fifth terminal
kit available

 10K ampere interrupting capacity (AIC)
standard

 Optional mounting base can be embedded
in concrete for fast, easy installation
termination section

 Separate sealable and lockable metering
section with the option of
EITHER:
	

Milbank ring-type socket with test /
bypass blocks (conforms to EUSERC 308)
OR

	

Milbank heavy duty ringless socket with
lever bypass

OPTIONAL FIFTH**
TERMINAL KIT

EXTERIOR
CABINET

CP3B111IRASP

105J

Steel, Light Green

Ring type meter socket with
test / bypass blocks

CP3B111IRASS

105J

Stainless Steel

Ring type meter socket with
test / bypass blocks

CP3B511IRASP

K3865

Steel, Light Green

METER SOCKET TYPE

Ringless heavy duty meter socket
with lever bypass

*NOTE: Chart shows standard, stocked items. Other options and features are available. Contact factory for options details and
availability.
*See page E2 for options (accessories) details.

Utility requirements for this equipment may vary. Always consult the serving utility for their requirements before ordering or
installing equipment in this catalog.

E7

COMMERCIAL METER PEDESTALS

 Separate sealable and lockable utility

SECTION E

The Milbank “IR” series Commercial Pedestals are
designed to provide a weather and vandal resistant
metered enclosure for irrigation controllers. Breakers and
a GFI duplex receptacle are provided to power the
irrigation controllers supplied
by others. A plywood
backboard is mounted behind
the deadfront door for
mounting the irrigation
controller. A large plan pocket
is mounted inside t h e
customer section door to
hold
plans
and
specifications. L i g h t g r e e n
powder coated steel or
stainless steel pedestals are
normally in stock.

STOCKED
PEDESTALS*

E7

E8

BBS/UPS SERIES

CP3B BBS & UPS Series
1Ø 3 wire 120/240 or 120/208 volt
Typical applications: Metered emergency
uninterrupted power for traffic intersections,
wireless - phone, communication equipment,
parking lots, camera and security locations.
The Milbank BBS / UPS Series Commercial Pedestals

Industrial Control Equipment”

 100 through 320 amp meter socket with the option
of either:
	

Milbank ring type socket (conforms to EUSERC 309)
with or without test / bypass blocks

	

Milbank heavy duty ringless socket with lever bypass

 Separate sealable utility termination compartment
 An isolated separate customer section with:
	

Service disconnects

loads, and also to switch specific loads on and off under

	

Power distribution options

	

Power control

be used to control lighting circuits as an example.

SECTION E

 NEMA 3R construction, UL listed as “Enclosed

are designed to provide continuous power for various
certain conditions. A photoelectric cell or time clock may

COMMERCIAL METER PEDESTALS

Features:

Metered and non-metered power distribution options are
available. The back-up power pedestal is designed to
handle the vast majority of todays back-up power
requirements. By using 19” rack design, shelves can be

 19” wide rack in customer compartment for easy
layout of equipment

 Battery trays
 Thermostat with cooling fan
 Filtered louvers for heat rise flow through ventilation
(UL Listed 508A)

adjusted to accommodate the required batteries and

 Three point door latch (key or pad lockable)

manufactures DC to AC inverters, transfer switches and

Options:

other related equipment. This design gives the user a
wide range of design and configuration options.
Complete turnkey, ready to power-up pedestals are
offered along with basic and custom configurations.

 Manual Bypass switch (used for maintenance of
BBS/UPS)

 Transfer switch for generator power back-up
 Generator inlet receptacles 30 amps through 200 amps
 Pad lockable provision for receptacles
 Police access door
 Metered load center distribution
 Non metered load center distribution
 Photo electric controls (for street lighting)
 Time clocks
 HOA switches
 Contactors
 GFI duplex receptacles
 Thermostat for heating control
 Heating pads or elements
 Roll out shelves for batteries
 Surge arrestors and lighting arrestors

Utility requirements for this equipment may vary. Always consult the serving utility for their requirements before ordering or
installing equipment in this catalog.

E8

POWER TRANSFER SERIES–METERED & UNMETERED

CP3B “Power Transfer” Series – Metered

CP3B “Power Transfer” Series
1Ø3W 120/240 volt thru 3Ø4W 277/480 volt
Typical applications: Traffic intersections,
Cell sites, Phone company broadband service,
Cable TV, Pump and Lift stations requiring
utility power with back up generator power

E9

The Milbank Commercial Pedestal “Power Transfer Series”
provides metered AC power, distribution, surge suppression,
mechanical interlock and stand by generator receptacle. All
electrical equipment including the generator receptacle is built
inside the pedestal, giving it a clean appearance and making it
extremely vandal resistant. 


Features & Options:

Features & Options:
 120/240v 1∅3W thru 277/480v 3∅4W ratings
 60 amps thru 400 amp ratings
 10K AIC up to 50K AIC ratings
 UL listed 508A, NEMA 3R rated
 Pad lockable, isolated utility compartments
 20 amp GFI convenience receptacle
 Utility and generator indicator light options
 All stainless steel hardware
 Galvanized steel, aluminum or stainless steel cabinet options
 Custom designs available
Utility requirements for this equipment may vary. Always consult the serving utility for their requirements before ordering or
installing equipment in this catalog.

E9

COMMERCIAL METER PEDESTALS

CP3B “Power Transfer” Series – Unmetered
The Milbank Commercial Pedestal “Power Transfer Series”
provides non metered AC power, distribution, surge
suppression, mechanical interlock and stand-by generator
receptacle – all in a neat, compact pedestal. 


SECTION E

Generator
Receptacle
Inside!

 120/240v 1∅3W thru 277/480v 3∅4W ratings
 Choice of EUSERC ring type or ringless meter sockets
 60 amps thru 400 amp ratings
 10K AIC up to 50K AIC ratings
 UL Listed 508A, NEMA 3R rated
 Pad lockable, isolated utility compartments
 20 amp GFI convenience receptacle
 Lockable recessed generator receptacle door
 Utility and generator indicator light options
 All stainless steel hardware
 Galvanized steel, aluminum or stainless steel cabinet options
 Custom designs available

E10

GENERAL SPECIFICATIONS

Example of specifications for a Metered Commercial
Pedestal
Commercial pedestal shall be type ______________ .
Catalog # _________________

COMMERCIAL METER PEDESTALS

SECTION E

Voltage rating :____(120/240v 1P 3W)__
AIC rating: ____10__
Amperage rating :____(100 amps)__
The pedestal shall be of NEMA Type 3R rainproof
construction and shall be UL Listed as “Enclosed
Industrial Control Equipment” (UL 508A). External
construction shall comply with UL50 requirements and
shall be of G90 galvanized steel with light green #14672
Federal Specification 595 polyurethane industrial grade
powder paint of 1.7 mil minimum thickness (unless
otherwise specified). Aluminum and stainless steel are
other factory options available. Internal construction shall
be G90 galvanized steel and 1.7 mil minimum thickness
polyurethane industrial grade powder coat painted or
bare aluminum. No fasteners except sealing screws
shall be removable by external access. Hinges shall be
stainless steel and of the continuous piano hinge type.
The pedestal mounting bolts shall not be externally
accessible. The pedestal shall be offered with an
optional base designed to be embedded in concrete in
place of anchor bolts. Either pedestal mounting base or
anchor bolt kit is required for installation.

The customer compartment door to be hinged on the left
hand side. A stainless pad-lockable hasp provided to
secure customer compartment. A door keeper provided
to keep the door in an open position. A print pocket on
the inside of the door shall hold all wiring schematics,
circuit directories and instructions in a clear,
weatherproof sleeve. Required UL labeling shall be
located on the inside of the customer door. Distribution
and control equipment shall be behind an internal deadfront door with a quarter-turn securing latch and be
hinged to open more than 90 degrees. The dead-front
door shall be hinged on the same side as the customer
section door. All distribution and control equipment shall
be factory wired using 600 volt wire sized to NEC and UL
requirements.
The service pedestal shall be rated for operation at 10K
minimum (AIC) amps interrupting capacity. The provided
documentation shall list circuit breaker combinations and
those to be used for de-rated operation for series ratings.
Circuit breakers shall be permanently labeled with
engraved name plates.

Utility requirements for this equipment vary. Always
consult the serving utility for their requirements before
ordering or installing this equipment.

The service pedestal must have three separate isolated
sections for metering equipment, utility termination and
customer equipment.
The metering section must be pad-lockable and sealable
and have a hinged swing back hood with an integral
hinged polycarbonate sealable window for access to
demand meters. An external nameplate shall be
permanently attached to the hood. A stainless steel
handle shall be provided on the front exterior of the hood.
Meter socket type shall meet the requirements of the
serving utility.
The utility termination section must be pad-lockable and
sealable and shall have a stainless steel handle provided
on a lift-off cover. Sufficient clearance shall be provided
for a 4-inch diameter conduit for utility cables entrance.
Utility landing lugs shall be UL listed and shall
accommodate #6 – 350 kcmil conductors.

E10

COMMERCIAL METER PEDESTAL DRAWINGS–16" METERED & UNMETERED

E11

“A” Style 16" Metered Commercial Pedestal
HINGED
DEMAND
METER
RESET
COVER
WITH
WINDOW
REMOVEABLE
TEST BYPASS
BLOCK COVER
(IF APPLICABLE)

FULLY HINGED
METER SECTION
COVER

36" MIN.
CLEARANCE

PER
MOUNTING BASE DETAIL REQUIRED
N.E.C 110-16

PHOTO CELL WINDOW
WITH SHIELD
(IF APPLICABLE)

PRINT
POCKET

TYPICAL
FRONT & BACK
16"
15"
14 1/2"
13"

PADLOCK
BRACKET
EXTENDS
THROUGH
DOOR
FOR
SECURITY

48"
42"

UTILITY
SECTION
14 1/2" 9 3/4"
16"
12 1/4"

LIFT-OFF
SERVICE
COVER

17"
ENCLOSURE
DEPTH

CUSTOMER
SECTION

SECTION E

23.5" UTILITY
TERMINATION
LANDING MIN.

HINGED
DEADFRONT

6 3/4"

ANCHOR BOLT
MOUNTING HOLES
PEDESTAL
MOUNTING HOLES

COMMERCIAL METER PEDESTALS

3" RECOMMENDED MIN.
FOUNDATION EXTENSION
ALL SIDES. 6" REC.

HINGED EXTERIOR DOOR
WITH DOOR STOP TO HOLD
DOOR IN OPEN POSITION

CP-16PDMNT-CALT
MOUNTING BASE

CP-16PDMNT-CALT
MOUNTING BASE

Pad Mount Base or (4) 5/8-11 X 18” Anchor Bolts Recommended

“E” Style 16" Unmetered Commercial Pedestal–Low Profile
PHOTO CELL WINDOW
WITH SHIELD
(IF APPLICABLE)

PRINT
POCKET

MOUNTING BASE DETAIL
LIFT-OFF
SERVICE
COVER

LATCH HASP
EXTENDS
THROUGH
DOOR FOR
SECURITY

16"
15"
14 1/2"
13"

32 1/4"
40 1/2"

36" MIN.
CLEARANCE
REQUIRED PER
N.E.C 110-16
TYPICAL
FRONT & BACK

UTILITY
SECTION

HINGED
DEADFRONT

23 7/8" UTILITY
TERMINATION
LANDING MIN.

16"

14 1/2" 9 3/4"
12 1/4"

CUSTOMER
SECTION

6 3/4"

17"
ENCLOSURE
DEPTH

ANCHOR BOLT
MOUNTING HOLES

HINGED
EXTERIOR
DOOR

PEDESTAL
MOUNTING HOLES

CP-16PDMNT-CALT
MOUNTING BASE

CP-16PDMNT-CALT
MOUNTING BASE

3" RECOMMENDED MIN.
FOUNDATION EXTENSION
ALL SIDES. 6" REC.
MINIMUM DEPTH.

Pad Mount Base or (4) 5/8-11 X 18" Anchor Bolts Recommended

Utility requirements for this equipment may vary. Always consult the serving utility for their requirements before ordering or
installing equipment in this catalog.

E11

E12

COMMERCIAL METER PEDESTAL DRAWINGS–24" METERED & UNMETERED

“B” Style 24" Metered Commercial Pedestal
“B” Style
24"
Metered
(With
one or
two
meters)Commercial Pedestal
HINGED DEMAND
METER RESET
COVER WITH
WINDOW
REMOVEABLE
TEST BYPASS
BLOCK COVER
(IF APPLICABLE)

FULLY HINGED
METER SECTION
COVER

MOUNTING BASE DETAIL
24"

PHOTO CELL WINDOW
WITH SHIELD
(IF APPLICABLE)

PRINT
POCKET

36" MIN.
CLEARANCE
REQUIRED PER
N.E.C 110-16
TYPICAL
FRONT & BACK

23"
22 1/2"
21"

PADLOCK
BRACKET
EXTENDS
THROUGH
DOOR
FOR
SECURITY

48"
42"

14 1/2" 9 3/4"
16"
12 1/4"

23.5" UTILITY
TERMINATION
LANDING MIN.

HINGED
DEADFRONT

SECTION E
COMMERCIAL METER PEDESTALS

UTILITY
SECTION

CP-24PDMNT-CALT
MOUNTING BASE

17"
ENCLOSURE
DEPTH

CUSTOMER
SECTION

ANCHOR BOLT
MOUNTING HOLES

LIFT-OFF
SERVICE
COVER

HINGED EXTERIOR DOOR
WITH DOOR STOP TO HOLD
DOOR IN OPEN POSITION

6 3/4"

PEDESTAL
MOUNTING HOLES

3" RECOMMENDED MIN.
FOUNDATION EXTENSION
ALL SIDES. 6" REC.
MINIMUM DEPTH.

CP-24PDMNT-CALT
MOUNTING BASE

Pad Mount Base or (4) 5/8-11 X 18" Anchor Bolts Recommended

“M”
Style
24"24"
Unmetered
Pedestal
“M”
Style
MeteredCommercial
Commercial
Pedestal
PHOTO CELL WINDOW
WITH SHIELD
(IF APPLICABLE)

PRINT
POCKET

MOUNTING BASE DETAIL
24"
22 1/2"
21 1/2"
21"

PADLOCK
BRACKET
EXTENDS
THROUGH
DOOR
FOR
SECURITY

CUSTOMER
SECTION

15 3/8"
17"
22 1/2"
UTILITY
TERMINATION
LANDING

HINGED
DEADFRONT

12 1/4"
14 1/4"

UTILITY TERM.
SECTION

6 1/2"

1 7/8""
1 1/2""

LIFT-OFF
SERVICE
COVER

CP-24PDMNT-CALT
MOUNTING BASE
HINGED EXTERIOR DOOR
WITH DOOR STOP TO HOLD
DOOR IN OPEN POSITION

CP-24PDMNT-CALT
MOUNTING BASE

3" RECOMMENDED MIN.
FOUNDATION EXTENSION
ALL SIDES. 6" RECOMMENDED
MINIMUM DEPTH.
36" MIN.
CLEARANCE
REQUIRED PER
N.E.C 110-16
TYPICAL
FRONT & BACK

Pad Mount Base or (4) 5/8-11 X 18" Anchor Bolts Recommended

Utility requirements for this equipment may vary. Always consult the serving utility for their requirements before ordering or
installing equipment in this catalog.

E12

COMMERCIAL METER PEDESTAL DRAWINGS–32" METERED

E13

“K” Style 32" Metered Commercial Pedestal
(With one or two meters)

SECTION E
COMMERCIAL METER PEDESTALS

(4) 5/8-11 X 18" Anchor Bolts Recommended
Catalog Number CP-ABK5/8

Utility requirements for this equipment may vary. Always consult the serving utility for their requirements before ordering or
installing equipment in this catalog.

E13

E14

COMMERCIAL METER PEDESTAL DRAWINGS–METERED

“D” Style Metered Commercial Pedestal
VENTILATED OPENINGS
W/ SOFFIT

LIFTING EYES

VENTILATION FAN

SLOPED ROOF

SECTION 3

SECTION 2

SECTION 4

SECTION 5
19.06
AVAILABLE
EQUIPMENT
SPACE

SECTION 1

PE SOCKET
KNOCKOUTS

1/4 TURN
PADLOCKABLE
HANDLES
SECTION 7

VENTILATION
LOUVERS
WITH FILTER

44.38

24.12
TO BOTTOM OF LUG

60.00
27.31
AVAILABLE
EQUIPMENT SPACE

48.56

SECTION E

24.00

“C” Style 54" Metered Commercial Pedestal
24.50

30.50

A
PE WINDOW

DEMAND METER
DOOR

DEMAND METER
WINDOW
19" RACK

METER DOOR

METER DOOR
PADLOCK-ABLE
CAM LATCH

METER
SECTION

CUSTOMER DOOR
CUSTOMER
DOOR
55.50

SEAL STUD
54.25

PADLOCK-ABLE
3-POINT CAM LATCH

19" RACK

REMOVEABLE
COVER PLATES
FOR INSTALLATION

B

A

B

UTILITY PULL
SECTION

COMMERCIAL METER PEDESTALS

SECTION 6

REMOVEABLE
UTILITY COVER

PADLOCK HASP

SEAL STUD

SECTION A-A
SCALE 1 : 16
REMOVEABLE
AIR FILTERS

PRINT
POCKET

3-POINT
CAM LATCH

19" RACK

Utility requirements for this equipment may vary. Always consult the serving utility for their requirements before ordering or
installing equipment in this catalog.

E14

COMMERCIAL METER PEDESTALS WORKSHEET

E15

Commercial Pedestal Worksheet
Phone (816)483-5314 ‡ Fax (816)483-6357
Please answer all of the questions as best as you can. Additional comments as to application and future requirements
will help Milbank will determine the best product for your job.

Distributor: __________________________ Phone: _________________ Fax: ___________________
Contact Name: _____________________________ Application: ______________________________
Milbank Representative: _______________________________ Salesmen: ______________________
Job Name & Location: _________________________________________________________________
Agency Specifications: (DOT-City-Other) _________________________________________________
Unit Amperage: ___________

Voltage: ____________ Phase: ____________ Wire: _____________

Meter socket (200 Amp)

RING-TYPE RINGLESS

Fifth Terminal?

NO YES (at _____ o’clock)

Meter socket (200 Amp)

RING-TYPE RINGLESS

Fifth Terminal?

NO YES (at _____ o’clock)

Amp: __________ Poles: __________ KAIC: __________

Main breaker requirements:

Amp: __________ Poles: __________ KAIC: __________

Interior #1 0-42 circuits ________ Load center ________ Panel board ________ Metered? YES

NO

Interior #2 0-42 circuits ________ Load center ________ Panel board ________ Metered? YES

NO

Amps:

Poles:

KAIC:

Label & Special requirements:

Qty _____Breakers

______

______

______

__________________________

Qty _____Breakers

______

______

______

__________________________

Qty _____Breakers

______

______

______

__________________________

Qty _____Breakers

______

______

______

__________________________

Qty _____Breakers

______

______

______

__________________________

Qty _____Breakers

______

______

______

__________________________

Controls:
Qty _____ Time Clock: 24 Hr _____ 7 Day _____ 365 Day Astro _____ Description: _______________
Qty _____ Photo Electric Control Receptacle
Qty _____ Test switch: 2 Pos. _____ 3 Pos. _____ HOA Type _____ Other ________________________
Qty _____ Control Transformer ___________ Voltage ___________VA Size (required for all 277/480v)
Contactors:
Type: Lighting - LT / Definite Purpose - DP / Mechanical Held - MH / Mercury - MV / IEC - IC
Qty ______

Type ______

Amps ______

Poles ______

Coil voltage ______

Other ________

Qty ______

Type ______

Amps ______

Poles ______

Coil voltage ______

Other ________

Qty ______

Type ______

Amps ______

Poles ______

Coil voltage ______

Other ________

Cabinet / Finish requirements:

Alum – Untreated = AO / Alum Anodized = AL / Stainless Steel = SS

Aluminum – Painted = A / GALVANIZED STEEL PAINTED
MINT GREEN

(STANDARD)

(STANDARD) _______

(specify paint below)

= G / Pine Green = PG / Dark Green = DG / Black = BK / Desert Tan = DT

White = W / Gray = P / Summerland Gray = SG / Other (RAL finish number) ____________________
Other Requirements: ___________________________________________________________________
_____________________________________________________________________________________
Please send any drawings, plans, specifications, and load/panel board schedules with worksheet

E15

COMMERCIAL METER PEDESTALS

Branch breakers:

SECTION E

Main breaker requirements:

NOTES

SECTION E

E16
NOTES

E16

F1

36 or 48

36.00 or 48.00

CURRENT TRANSFORMER CABINETS–TYPE 3R–DOOR MOUNT CT RATED SOCKET

363612-CT3R-SP
364812-CT3R-SP2

SECTION F

NO. OF CATALOG
TERMS. NUMBER BYPASS CONNECTORS AMPS

K4806-BP Plunger #14-4 Max 20 A

13

DIMENSIONS
D"

W"

H"

21⁄2

77⁄8

71⁄2

BP: The -BP suffix indicates plunger bypass.
12184-LC3R

CURRENT TRANSFORMER RATED CABINETS—TYPE 3R
CATALOG
NUMBER
243210-LC3R-SP
323610-LC3R-SP
363016-CT3R
363612-CT3R-SP
364812-CT3R-SP2

D"

W"

H"

GAUGE
OF
STEEL

10
10
16
12
12

24
32
36
36
36

32
36
30
36
48

14
14
14
14
14

DIMENSIONS

PANEL SIZE
W" x H"
21
29
33
33
33

29
33
27
33
45

PANEL & BACKBOARD CATALOG NUMBERS
PAINTED STEEL PANEL

WOOD BACKBOARD

A-24P32
A-32P36
A-36P30
A-36P36
A-48P36

A-24P32W
A-32P36W
A-36P30W
A-36P36W INCLUDED
A-48P36W INCLUDED

Utility requirements for this equipment may vary. Always consult the serving utility for their requirements before ordering or
installing equipment in this catalog.

F1

CT CABINETS, TEST SWITCHES, POLYPHASE ENCLOSURES

DOOR MOUNT C.T. RATED SOCKET

F2

CURRENT TRANSFORMER CABINETS

CT203611-HC

CT18249-SC

CT CABINETS, TEST SWITCHES, POLYPHASE ENCLOSURES

SECTION F

SCREW COVER
CATALOG
NUMBER

C.T.
RACKS

SIZE
W" X H" X D"

FRONT
COVER

CT24329-SC
CT242411-SC
CT243011-SC
CT243611-SC
CT244811-SC
CT303011-SC
CT303611-SC
CT303614-SC
CT363611-SC
CT364211-SC
CT364811-SC
CT364814-SC
CT424211-SC
CT484811-SC

C, M
A4, C, M
A4, C, M
A4, C, J, M
A, C, D, G, J, M
A4, B4, C, E, L, M
A4, B4, C, E, J, K, L, M
A4, B4, C, E, J, K, L, M
A4, B4, C, E, J, K, L, M
A4, B4, C, E, J, K, L, M
A, B, C, D, E, F, G, H, J, K, L, M
A, B, C, D, E, F, G, H, J, K, L, M
A4, B4, C, E, J, K, L, M
A, B, C, D, E, F, G, H, J, K, L, M

24 X 32 X 9
24 X 24 X 11
24 X 30 X 11
24 X 36 X 11
24 X 48 X 11
30 X 30 X 11
30 X 36 X 11
30 X 36 X 14
36 X 36 X 11
36 X 42 X 11
36 X 48 X 11
36 X 48 X 14
42 X 42 X 11
48 X 48 X 11

1 PIECE
1 PIECE
1 PIECE
1 PIECE
1 PIECE
1 PIECE
1 PIECE
1 PIECE
1 PIECE
2 PIECES
2 PIECES
2 PIECES
2 PIECES
2 PIECES

HINGE COVER
CATALOG
NUMBER

C.T.
RACKS

SIZE
W" X H" X D"

FRONT
COVER

CT203611-HC
CT243011-HC
CT243611-HC
CT244811-HC
CT303611-HC
CT304811-HC
CT363611-HC
CT364811-HC
CT484811-HC
CT364814-HC
CT484814-HC

C
A4, C, M
C, M
A, C, D, G, J, M
A4, B4, C, E, J, K, L, M
A, B, C, D, E, F, G, H, J, K, L, M
A4, B4, C, E, J, K, L, M
A, B, C, D, E, F, G, H, J, K, L, M
A, B, C, D, E, F, G, H, J, K, L, M
A, B, C, D, E, F, G, H, J, K, L, M
A, B, C, D, E, F, G, H, J, K, L, M

20 X 36 X 11
24 X 30 X 11
24 X 36 X 11
24 X 48 X 11
30 X 36 X 11
30 X 48 X 11
36 X 36 X 11
36 X 48 X 11
48 X 48 X 11
36 X 48 X 14
48 X 48 X 14

1 PIECE
1 PIECE
1 PIECE
1 PIECE
1 PIECE
1 PIECE
1 PIECE
1 PIECE
2 PIECE
2 PIECE
2 PIECE

ENCLOSURE: These units are rated Type 3R, powder coated, and constructed of galvanized steel.
MOUNTING RACK: Select CT mounting rack from next page.
MOUNTING: 1/4-20 welded studs.

Utility requirements for this equipment may vary. Always consult the serving utility for their requirements before ordering or
installing equipment in this catalog.

F2

CURRENT TRANSFORMER CABINETS–MOUNTING RACKS

K4798

K4797

K4793 / K4795

K4729

CODE

CATALOG
NUMBER

AIC
RATING

AMPS

VOLTS

TYPE OF
SERVICE

TERMINATION TYPE

A4

K4797

50K

400

600

1∅3W

1/2-13 studs on 1-3/4" centers

A

K4797

50K

800

600

1∅3W

1/2-13 studs on 1-3/4" centers

B4

K4798

50K

400

600

3∅4W

1/2-13 studs on 1-3/4" centers

B

K4798

50K

800

600

3∅4W

1/2-13 studs on 1-3/4" centers

C

K4793

10K

201-400

600

1∅3W

1/2-13 studs on 1-3/4" centers

D

K4795

10K

401-800

600

1∅3W

1/2-13 studs on 1-3/4" centers

E

K4794

10K

201-400

600

3∅4W

1/2-13 studs on 1-3/4" centers

F

K4796

10K

401-800

600

3∅4W

1/2-13 studs on 1-3/4" centers

G

K4729

50K

800

600

1∅3W

(3) #4 - 600 or (6) #1 - 250

H

K4722

50K

800

600

3∅4W

(3) #4 - 600 or (6) #1 - 250

J

K4903

50K

400

600

1∅3W

(1) #4 - 600 or (2) #1 - 250

K

K4904

50K

400

600

3∅4W

(1) #4 - 600 or (2) #1 - 250

L

K5747

50K

800

600

3∅4W

M

K5752

50K

800

600

1∅3W

Line: 1/2-13 studs on 1-3/4" centers
Load: (3) #4 - 600 or (6) #1 - 250
Line: 1/2-13 studs on 1-3/4" centers
Load: (3) #4 - 600 or (6) #1 - 250

Select CT enclosures from previous page.

Utility requirements for this equipment may vary. Always consult the serving utility for their requirements before ordering or
installing equipment in this catalog.

F3

CT CABINETS, TEST SWITCHES, POLYPHASE ENCLOSURES

CURRENT TRANSFORMER ENCLOSURE MOUNTING RACKS

SECTION F

K4722

F3

METERED TRANSFORMER CABINETS–OVERHEAD & UNDERGROUND

CT CABINETS, TEST SWITCHES, POLYPHASE ENCLOSURES

SECTION F

F4

U3565-O

METERED TRANSFORMER CABINETS—RING TYPE
NO.
DIMENSIONS
OF
TERMS D" W" H"
6
11
24
42

SERVICE

HUB

CATALOG
NUMBER

C.T.
RACKS

OH

H.O.

U3320-R

A, C, D, J, L, M

OH

H.O.
H.O.

U3322-R

B, E, F, G, H, L, M

13

11

36

42

3∅4W Υor Δ

OH

U3555-R

B, E, F, G, H, L, M

15

11

36

42

3∅4W Υor Δ

UG

NONE

U3340-O

A, C, D, J, L, M

6

11

24

52

1∅3W

UG

NONE

U3342-O

B, E, F, G, H, L, M

13

11

36

52

3∅4W Υor Δ

UG

NONE

U3565-O

B, E, F, G, H, L, M

15

11

36

52

3∅4W Υor Δ

TYPE OF
SERVICE
1∅3W

METER SOCKET: 20 amp current transformer meter socket built in.
ENCLOSURE: NEMA Type 3R with screw cover.
CURRENT TRANSFORMER MOUNTING: 1/4-20 welded studs.
HUBS: For proper hub selection, see hub suffix chart in the accessory section.
SEALING RINGS: Supplied with MR-4 screw type sealing ring.
MOUNTING RACKS: For mounting rack information refer to previous page.

Utility requirements for this equipment may vary. Always consult the serving utility for their requirements before ordering or
installing equipment in this catalog.

F4

20 AMP— 4, 5, 6, 7, 8, & 13 TERMINAL
CURRENT TRANSFORMER RATED—RINGLESS / RING TYPE

2

1

4

F5

3

4
5

UC7237-RL

UC7582-XL

NO.
METER
OF
FORM
TERMS

HUB

3S

UC1290-XL

6

4S

UC1299-XL

7

7,14,15 &
24S

UC7233-XL

8

5S

UC7235-XL

13

6,8,9S &
(ALT) 10S

5

UC7237-XL

DIMENSIONS

CONCENTRIC K.O.ʼS

CONNECTORS
CU

BYPASS

D"

W"

H"

1

2

3

4

5

C.P.

#14 - #10

PLUNGER*

35⁄16

8

14

11⁄2

11⁄4

11⁄4

2

11⁄4

1

C.P.

#14 - #10

PLUNGER*

35⁄16

8

14

11⁄2

11⁄4

11⁄4

2

11⁄4

1

C.P.

#14 - #10

PLUNGER*

5

3 ⁄16

8

14

11

11

11

⁄4

2

11

⁄4

1

C.P.

#14 - #10

PLUNGER*

35⁄16

8

14

11⁄2

11⁄4

11⁄4

2

11⁄4

1

#14 - #10

PLUNGER*

3 ⁄16

14

11

11

11

2

11

1

C.P.

8

5

⁄2
⁄2

⁄4
⁄4

⁄4

⁄4

6

⁄4
⁄4
⁄4
⁄4
⁄4

RING TYPE–PLUNGER TYPE BYPASS–OVERHEAD / UNDERGROUND
NO.
METER
OF
FORM
TERMS
5
6
8
13
13

3S
4S
5S
6,8,9S &
(ALT) 10S
6,8,9S &
(ALT) 10S

CATALOG
NUMBER
UC1291-RL
UC1300-RL
UC7544-RL

HUB
H.O.
H.O.
H.O.

CONNECTORS
CU

BYPASS

#14 - #4 MAX

PLUNGER*

#14 - #4 MAX

PLUNGER*

#14 - #4 MAX

PLUNGER*

UC7545-RL

H.O.

#14 - #4 MAX

PLUNGER*

UC7582-XL

C.P.

#14 - #10

NONE

DIMENSIONS

CONCENTRIC K.O.ʼS

D"

W"

H"

1

2

3

4

5

5

8

14

11⁄2

11⁄4

11⁄4

2

11⁄4

1

11

11

⁄4

2

11

⁄4

1

2

11⁄4

1

3

⁄16

6

⁄4

5

8

14

11

5

8

14

11⁄2

11⁄4

11⁄4

11

11

⁄4

2

11

⁄4

1

11⁄4

11⁄4

2

11⁄4

1

3
3

⁄16
⁄16

⁄2

5

⁄16

8

14

11

3 ⁄16

8

14

11⁄2

3

5

⁄2

⁄4
⁄4

⁄4
⁄4
⁄4
⁄4

HUBS: For proper hub selection see the hub suffix chart on the accessory page.
*BYPASS: Plunger type bypass automatically closes when meter is removed.
CONNECTORS: Units are supplied with sleeve type connectors (#14-#2)

Utility requirements for this equipment may vary. Always consult the serving utility for their requirements before ordering or
installing equipment in this catalog.

F5

CT CABINETS, TEST SWITCHES, POLYPHASE ENCLOSURES

CATALOG
NUMBER

SECTION F

RINGLESS—PLUNGER TYPE BYPASS–OVERHEAD / UNDERGROUND

F6

20 AMP–600 VAC–5, 6, 8, 13, & 15 TERMINAL
CURRENT TRANSFORMER—TEST SWITCH PROVISION

2

1

3

4

5
6

3425 7636
3426 7461
3428
3423
1

3

2

1

3435
3436
3438
3433
3434

5

4

UC3423-XL
UC3438-XL-TS080025
(with test switch factory installed)

RINGLESS—WITH PROVISION FOR TEST SWITCH–TWO PIECE FRONT

CT CABINETS, TEST SWITCHES, POLYPHASE ENCLOSURES

SECTION F

NO.
OF SERVICE
TERMS

CATALOG
NUMBER

HUB

DIMENSIONS

CONCENTRIC K.O.ʼS

CONNECTORS

BYPASS

D"

W"

H"

1

2

3

4

5

6

5

OH / UG

UC3425-XL

C.P.

#14 - #2

NONE

51⁄8

12

20

11⁄4

11⁄4

11⁄4

11⁄4

11⁄4

1 1
4, 2

6

OH / UG

UC3426-XL

C.P.

#14 - #2

NONE

1

5 ⁄8

12

20

11

11

11

11

11

⁄4

1 1
4, 2

8

OH / UG

UC3428-XL

C.P.

#14 - #2

NONE

51⁄8

12

20

11⁄4

11⁄4

11⁄4

11⁄4

11⁄4

1 1
4, 2

13

OH / UG

UC3423-XL

C.P.

#14 - #2

NONE

5 ⁄8

12

20

11

11

11

11

11

1 1
4, 2

1

⁄4
⁄4

⁄4
⁄4

⁄4
⁄4

⁄4
⁄4

⁄4

⁄ ⁄
⁄ ⁄
⁄ ⁄
⁄ ⁄

*RING TYPE—TEST SWITCH FACTORY PREWIRED—TWO PIECE FRONT
APPROVED FOR TUCSON ELECTRIC POWER
NO.
OF SERVICE
TERMS

CATALOG
NUMBER

6

OH

UC7636-YL-TGE-DES 11⁄4"

13

OH

UC7461-YL-TGE-DES

⁄4"

11

DIMENSIONS

CONCENTRIC K.O.ʼS

BYPASS

D"

W"

H"

1

2

3

4

5

6

#14 - #2

TEST
SWITCH

41⁄8

12

20

11⁄4

11⁄4

11⁄4

11⁄4

11⁄4

1 1
4, 2

#14 - #2

TEST
SWITCH

41

12

20

11

11

11

11

11

1 1
4, 2

HUB CONNECTORS

⁄8

⁄4

⁄4

⁄4

⁄4

⁄4

⁄ ⁄
⁄ ⁄

*RING TYPE—WITH PROVISIONS FOR TEST SWITCH—EUSERC COMPLIANT–TWO PIECE FRONT
NO.
OF SERVICE
TERMS

CATALOG
NUMBER

HUB

DIMENSIONS

CONCENTRIC K.O.ʼS

CONNECTORS

BYPASS

D"

W"

H"

1

2

3

4

5

6

5

OH / UG

UC3435-XL

C.P.

#14 - #2

NONE

51⁄8

12

20

2

2

2

2

2

—

6

OH / UG

UC3436-XL

C.P.

#14 - #2

NONE

51⁄8

12

20

2

2

2

2

2

—

8

OH / UG

UC3438-XL

C.P.

#14 - #2

NONE

51⁄8

12

20

2

2

2

2

2

—

13

OH / UG

UC3433-XL

C.P.

#14 - #2

NONE

51⁄8

12

20

2

2

2

2

2

—

15

OH / UG

UC3434-XL

C.P.

#14 - #2

NONE

51⁄8

12

20

2

2

2

2

2

—

*SEALING RINGS: Ring type units are supplied with one MR-4, screw type, sealing ring.
PREWIRING: If factory prewiring is required consult factory before ordering. Please include meter socket catalog number, test
switch number, meter form number, and a copy of your wiring diagram.
TEST SWITCH COVERS: Units on this page can be used with clear lexan cover (except units 7636 and 7461).
CONNECTORS: Units are supplied with sleeve type connectors (#14-#2)
HUBS: For proper hub selection see the hub suffix chart in accessory section.

Utility requirements for this equipment may vary. Always consult the serving utility for their requirements before ordering or
installing equipment in this catalog.

F6

MILBANK TEST SWITCHES—4, 7, & 10 POLE

SWITCH BLADES

TEST SWITCH BASE

POLARITY BARRIER

Two dimples coined into one side
of the switch blade ensure
positive contact in corrosive,
sooty environments—even after
years of inactivity.

The base is molded from a high
strength, fiberglass reinforced,
thermoset polyester. This
material is track resistant, flame
retardant and has low water
absorption qualities. Bases are
available in 7 pole and 10 pole
sizes.

For maximum protection potential
circuits are supplied with
permanently mounted, rigid
barriers made from high tensile
strength, polycarbonate.

TEST SWITCH COVERS

CURRENT CARRYING PARTS

SWITCH JAWS

FLUSH MOUNT COVER
BLACK

STANDARD COVER

Units must be
5 1/8" deep
for Cover

K3388-BLK-FL

K3388
FACTORY INSTALLED: For cover installed add the suffix -WC or -WCFL to the catalog number of
desired test switch
FIELD INSTALLED: For field installed cover order kit number K3388 or K3388-BLK-FL.

The MILBANK test switch is designed to meet the critical requirements of the electric utility industry. Not only do they meet EEI,
ANSI C12.9, and UL standards but they combine several special features giving the MILBANK test switch increased safety,
durability and reliability. One such feature is our unique switch blade contact points which cut through residue that builds up after
years of service. Another distinction is our polarity barrier which is designed to be flexible as well as offer exceptional insulating
qualities. Our test switches are constructed from the latest materials available using modern fabricating and assembly methods.

Utility requirements for this equipment may vary. Always consult the serving utility for their requirements before ordering or
installing equipment in this catalog.

F7

CT CABINETS, TEST SWITCHES, POLYPHASE ENCLOSURES

The switch blade jaw clips are
constructed from spring grade
copper alloy. The material and
design ensure excellent contact
which prevents overheating.

Highly conductive copper and
copper alloy materials are used
on all current carrying parts. This
ensures conductivity and deters
corrosion. Spring grades are
used where appropriate. Plating
is available if required. Contact
general offices to special order.

SECTION F

Standard test switch covers are
made from break resistant, clear,
thermal plastic which has
excellent tracking and moisture
resistant properties. If covers are
required, add suffix “-WC” (with
cover) to the catalog number or
order separately catalog number
K3388. Black flush mount
covers are also available. Order
catalog number K3388-BLK-FL.
10 pole base only.

F7

F8

TEST SWITCHES—4, 7 & 10 POLE—600 VAC–PER ANSI C12.9 STANDARD

3 1/2"

7 1/2"

3 1/2"

CATALOG
NUMBER

CT CABINETS, TEST SWITCHES, POLYPHASE ENCLOSURES

SECTION F

9 1/2"

C+
C

X

P

Pn

X

C+

C

X

TS04-0104

X

C+

C

X

P

Pn

X

C+

C

7-POLE

TS07-0105

Potential Switch

P

P

Pn

C+

C

Line side current switch with
short circuit assembly
Load side current switch with
test jack assembly

N

Neutral bar ( no switch )

Pn

Neutral potential switch

X

TS04-0101

CATALOG
NUMBER

KEY
P

4-POLE

CATALOG
NUMBER

7-POLE ON A 10 POLE BASE

TS07-0049

P

X

P

X

Pn

X

C+

C

C

C+

TS07-0106

X

P

C+

C

P

C+

C

Pn

X

X

Unused position on base
Insulating barrier, isolates both
sides of switch

CATALOG
NUMBER
CUSTOM POLE ARRANGEMENTS:
The key may be used to diagram your
own pole arrangement. Be sure to
specify base size and whether all C+
line side, current switch / shunt circuit
assemblies are to be bussed together.
The catalog numbers shown above are
connected in line-load pairs; therefore,
if bussed is required, different catalog
numbers will apply.

10-POLE

TS10-0109

P

P

P

Pn

C+

C

C+

C

C+

C

TS10-0110

P

C+

C

P

C+

C

P

C+

C

Pn

TS10-0111

P

P

P

Pn

C

C+

C

C+

C

C+

TS10-0112

C+

C

C+

C

C+

C

P

P

P

Pn

TS10-0016

P

P

P

PN

C

C+

C

C+

C

C+

Utility requirements for this equipment may vary. Always consult the serving utility for their requirements before ordering or
installing equipment in this catalog.

F8

MILBANK TEST SWITCH WORKSHEET

F9

CUSTOMER NAME: __________________________________________
ADDRESS: __________________________________________________
____________________________________________________________
PHONE / FAX:_____________________ / ________________________

HANDLE COLOR KEY

TEST SWITCH BASE
The base is molded from a high strength, fiberglass
reinforced, thermoset polyester. This material is
track-resistant, flame-retardant and has low water
absorption qualities. Bases are available in two
standard sizes following NEMA mounting
classifications.

BK

Black

P

Purple

Y

Yellow

R

Red

BL

Blue

W

White

BR

Brown

GR

Grey

O

GN

Green

BKS BK/Stripe

Orange WS W/Stripe

POLE POSITION CHART
1

2

3

4

5

6

7

8

9

10

FEATURE

1

2

3

4

5

6

7

8

9

10

GANGED HANDLES (C)
BUSSING
COLORED HANDLES
ENGINEERING INFORMATION:____________________________________________________________________________
______________________________________________________________________________________________________
______________________________________________________________________________________________________
______________________________________________________________________________________________________
______________________________________________________________________________________________________

KEY
P
C+
C

Potential Switch
Line side current switch with
short circuit assembly
Load side current switch with
test jack assembly

N

Neutral bar ( no switch )

Pn

Neutral potential switch

X

Unused position on base
Insulating barrier, isolates both
sides of switch

CUSTOM POLE ARRANGEMENTS: The key may be used to diagram your own pole
arrangement. Be sure to specify base size and whether all C+ line side, current switch /
shunt circuit assemblies are to be bussed together. The catalog numbers shown above
are connected in line-load pairs; therefore, if bussed is required, different catalog
numbers will apply.

NUMBER OF POLES

TEST SWITCH COVER*

BASE SIZE












4
7
10

YES ___ CLEAR ___ BLACK
NO

7 POLE
10 POLE

*Test switch covers are only
available for 10 pole bases.

OTHER ______

Utility requirements for this equipment may vary. Always consult the serving utility for their requirements before ordering or
installing equipment in this catalog.

F9

CT CABINETS, TEST SWITCHES, POLYPHASE ENCLOSURES

45° ANGLE STOPS

SECTION F

SPECIAL FEATURES

NOTES

SECTION F

F10
NOTES

F10

125 AMP–MOBILE HOME METERED PEDESTAL–HARDWIRED–120/240 VAC

G1

STANDARD CONFIGURATIONS

78"

SERVICE PEDESTALS

49-1/2"

GRADE LEVEL

SECTION G

24"

MPRV-100-MB-78
4"

8"

SINGLE

SPECIFICATIONS
• UL Listed 100 amp continuous duty meter socket.
• 120/240 volt single phase service.

CATALOG NUMBER

DESCRIPTION

MPRV-BLANK-78

Ring type, parallel wired

MPRV-BLANK-78-R-5T

Ringless, horn bypass

MPRV-100-78

Ring type, parallel wired

• Space for four (4) single, or one double (240V C/B centerpositions only) and two (2) single pole universal style,
plug-in circuit breakers.

MPRV-100-MB-78

Ring type, series wired

• Ringless version equipped with horn bypass as standard.

MPRV-100-20GR-78

Ring type, parallel wired

• For fifth terminal field installed order kit 105J in the
3 oʼclock or 9 oʼclock position.

MPRV-50-78

Ring type

• Direct rear feed kit PF-KR included.

MPRV-503020GR-78

Ring type

• Specify MPRV-100-78 for 100 amp service pedestal with
direct feed kit and 100 amp CB wired in parallel. Space
for two additional single pole CBs provided. Series wiring
available; specify MPRV-100-MB-78.

• Twin line termination lugs #6-350 kcmil CU/AL per phase
for looping.

• MR-2 sealing ring standard with ring type cover.
• No knockouts.

Utility requirements for this equipment may vary. Always consult the serving utility for their requirements before ordering or
installing equipment in this catalog.

G1

G2

200 AMP–MOBILE HOME METERED PEDESTAL—HARDWIRED—120/240VAC

9"

54"
49-1/2"

27"
78"

SECTION G

SERVICE PEDESTALS

GRADE LEVEL

24"

4"

4"

8"

STANDARD CONFIGURATIONS

MPAP-200-78

A
BLANK

G

N

B

100A thru 200A

200-20GR
1-20A/125V

SINGLE

DOUBLE

SPECIFICATIONS
• 120/240 volt single phase service.

CATALOG NUMBER

DESCRIPTION

MPAP-BLANK-78

Ring type, parallel wired

MPAP-BLANK-78-R

Ringless, horn bypass, parallel wired

MPAP-100-78

Ring type, parallel wired

MPAP-100-MB-78

Ring type, series wired

MPAP-200-78

Ring type, parallel wired

MPAP-200-MB-78

Ring type, series wired

MPAP-200-20GR-78

Ring type, parallel wired

MPAPD-BLANK-78

Ring type, parallel wired

MPAPD-BLANK-78R

Ringless, horn bypass, parallel wired

• Twin line termination lugs #6-350 CU/AL per phase
for looping.
• UQFP breaker provisions factory wired in parallel with
branch breaker bus. Series wiring available. Specify
MB after breaker rating, ex. MPAP-200-MB.
• Furnished with space for four single or one double
(240V C/B center-positions only) and two single pole
universal style, plug-in circuit breakers in addition to
main.
• Ringless version equipped with horn bypass as
standard.
• For fifth terminal field installed order kit 105J in the
3 oʼclock or 9 oʼclock position.
• Direct rear feed kit PF-KR included.
• MR-2 sealing ring standard with ring type cover.

Utility requirements for this equipment may vary. Always consult the serving utility for their requirements before ordering or
installing equipment in this catalog.

G2

100 / 200 AMP—LOAD CENTER POWER PEDESTALS
ALL PURPOSE & RV APPLICATIONS

10"

G3

12 5/8"

30"
??"

??"
48"

80"
23-3/4"

??"
27"

Grade Level

SERVICE PEDESTALS

24"

6"
4"

8"

N

B

5 5

3

5 5 MPRV

2

5 5
4

1

5 5 MPAP
4

G1 N1

SECTION G

A

Left
Side
Only
MPAP

MPAP-200-MBLC-80

G

100 & 200 AMP—LOAD CENTER POWER OUTLETS
CATALOG
NUMBER

DESCRIPTION

MPRV-100-MBLC-80
MPAP-200-MBLC-80

CONCENTRIC K.O.ʼS
(INCHES)

1

2

3

4

5

100 Amp Metered Pedestal with (8) Circuit Load Center

21⁄2

2

11⁄2

11⁄4

1 3
2, 4

200 Amp Metered Pedestal with (8) Circuit Load Center

21⁄2

2

11⁄2

11⁄4

1 3
2, 4

⁄ ⁄
⁄ ⁄

SPECIFICATIONS
• UL Listed 100 / 200 amp continuous duty meter socket.
• Approved for 120/240 volt single phase service.
• Twin line termination lugs #6-350 CU/AL per phase for looping. Rear termination
• Space for (8) single, or (4) double and two single pole universal style plug-in circuit breakers
• Series main breaker factory installed.
• Direct feed lugs standard.

Utility requirements for this equipment may vary. Always consult the serving utility for their requirements before ordering or
installing equipment in this catalog.

G3

200 AMP SERIES U5240 & U5241 RING TYPE METERED PEDESTALS

SECTION G

SERVICE PEDESTALS

G4

U5240-O-200S with series wired
main & K5400-520GR kit

SPECIFICATIONS
• UL Listed – conforms to EUSERC drawing number 307
• 200 amp maximum, 120/240 volt, single phase, three wire meter socket
• Ring type meter socket with stainless steel screw-type sealing ring
• Short circuit withstand rating 22K AIC.
• Type 3R construction for durable outdoor use, one piece post – lockable and sealable
• Milbank grey polyester powder coat finish
• Wire terminations accept copper or aluminum conductors
• Line & Neutral: (2) #6-350 kcmil per phase
• Line Ground: (4) #14-1/0
• Load (CB): 2/0 to 300 kcmil per pole
• Load Neutral: (1) #6-350 kcmil
• Load Ground: (2) #14-1/0, (4) #14/6
• Milbank plug-in main circuit breaker. Available in 100, 125, 150 & 200 amp. Type UQFPH-M.
• Four-circuit plated copper interior accepts (2) 2-pole or (4) 1-pole standard plug-in type circuit breakers up to a
total of 125 amps maximum. Acceptable manufacturers: Cutler-Hammer, GE or Siemens
• Factory or field installable receptacle bridge and receptacle / circuit breaker kits available. See accessories.
Utility requirements for this equipment may vary. Always consult the serving utility for their requirements before ordering or
installing equipment in this catalog.

G4

200 AMP SERIES U5240 & U5241 RING TYPE METERED PEDESTALS

G5

SINGLE PEDESTAL (Direct Burial)
CATALOG NUMBER

MAIN BREAKER

MAIN CB

BRANCH

WEIGHT (lbs)



U5240-O-100S



UQFPH-M-100

100

4 Circuit

82



U5240-O-200S



UQFPH-M-200

200

4 Circuit

82



U5240-O (parallel wired)

—

4 Circuit

80

200

4 Circuit

82

—

4 Circuit

80

provision for UQFPH-M Series

SINGLE PEDESTAL (Pad Mount)


U5242-O-200S

UQFPH-M-200



U5242-O (parallel wired)

provision for UQFPH-M Series

DOUBLE PEDESTAL (Direct Burial)
MAIN BREAKER

MAIN CB

BRANCH

WEIGHT (lbs)



U5241-O-100S

(2) UQFPH-M-100

100

4 Circuit

115



U5241-O-200S

(2) UQFPH-M-200

200

4 Circuit

115



U5241-O (parallel wired)

provision for (2) UQFPH-M Series

—

4 Circuit

111

—

4 Circuit

111

DOUBLE PEDESTAL (Pad Mount)
U5243-O (parallel wired)

provision for (2) UQFPH-M Series

RECEPTACLE / CIRCUIT BREAKER KITS AND ACCESSORIES (ORDER SEPARATELY)
RECEPTACLE

CIRCUIT BREAKER CONDUCTOR CONFIGURATION



K5400-520GR

5-20R Duplex GFI

20 Amp, 1 Pole

12 Awg



K5400-TT30

TT30R

30 Amp, 1 Pole

10 Awg



K5400-1450

14-50R

50 Amp, 2 Pole

8 Awg



K5400-BRIDGE-1POS

Self-grounded one position receptacle bridge with hardware



K5400-BRIDGE-2POS

Self-grounded two position receptacle bridge with hardware



K5415

Stabilizer Foot with hardware



K5035

Pad Mount Kit with hardware for U5242/43 pad mount pedestals required



K5T

5th Terminal for 208y / 120 volt 3-wire service



K5193

Bus kit to convert series-wired main breaker to parallel



K5194

Wire kit to convert parallel-wired main breaker to series



K3450

Telephone / CATV mounting bracket (mounts left or right)



K5039

Penta bolt utility cover

GFI Rec.

• Up to two receptacle / circuit breaker kits can be field-installed in each powerhead. Order mounting bridge and
receptacle kits separately from above. For three receptacles or factory-installed kits, contact factory.
• Receptacle / circuit breaker kits include receptacle, circuit breaker, connected wire, cover plate and mounting
screws. Other receptacle / circuit breaker kits available.
• K5415 Stabilizer Foot sold separately. Recommended for double pedestals.
• Pad mount pedestals require K5035 pad mount kit. Order separately.
 Stock item – availability subject to prior sale.

Non-stock items – minimum order quantity required.
Utility requirements for this equipment may vary. Always consult the serving utility for their requirements before ordering or
installing equipment in this catalog.

G5

SECTION G

CATALOG #

SERVICE PEDESTALS

CATALOG NUMBER

200 AMP SERIES U5136 & U5137 RINGLESS METERED PEDESTALS

SECTION G

SERVICE PEDESTALS

G6

U5136-O-200S with series wired
main & K5400-520GR kit

SPECIFICATIONS
• UL Listed – conforms to EUSERC drawing number 307
• 200 amp maximum, 120/240 volt, single phase, three wire meter socket
• Ringless meter socket with horn bypass and stainless steel latch
• Short circuit withstand rating 22K AIC.
• Type 3R construction for durable outdoor use, one piece post – lockable and sealable
• Milbank grey polyester powder coat finish
• Wire terminations accept copper or aluminum conductors
• Line & Neutral: (2) #6-350 kcmil per phase
• Line Ground: (4) #14-1/0
• Load (CB): 2/0 to 300 kcmil per pole
• Load Neutral: (1) #6-350 kcmil
• Load Ground: (2) #14-1/0, (4) #14/6
• Milbank plug-in main circuit breaker. Available in 100, 125, 150 & 200 amp. Type UQFPH-M.
• Four-circuit plated copper interior accepts (2) 2-pole or (4) 1-pole standard plug-in type circuit breakers up to a
total of 125 amps maximum. Acceptable manufacturers: Cutler-Hammer, GE or Siemens
• Factory or field installable receptacle bridge and receptacle / circuit breaker kits available. See accessories.

Utility requirements for this equipment may vary. Always consult the serving utility for their requirements before ordering or
installing equipment in this catalog.

G6

200 AMP SERIES U5136 & U5137 RINGLESS METERED PEDESTALS

G7

SINGLE PEDESTAL (Direct Burial)
CATALOG NUMBER

MAIN BREAKER

MAIN CB

BRANCH

WEIGHT (lbs)



U5136-O-100S



UQFPH-M-100

100

4 Circuit

82



U5136-O-200S



UQFPH-M-200

200

4 Circuit

82



U5136-O (parallel wired)

—

4 Circuit

80

200

4 Circuit

82

—

4 Circuit

80

provision for UQFPH-M Series

SINGLE PEDESTAL (Pad Mount)
U5138-O-200S

UQFPH-M-200

U5138-O (parallel wired)

provision for UQFPH-M Series

DOUBLE PEDESTAL (Direct Burial)
MAIN BREAKER

MAIN CB

BRANCH

WEIGHT (lbs)



U5137-O-100S

(2) UQFPH-M-100

100

4 Circuit

115



U5137-O-200S

(2) UQFPH-M-200

200

4 Circuit

115



U5137-O (parallel wired)

provision for (2) UQFPH-M Series

—

4 Circuit

111

RECEPTACLE / CIRCUIT BREAKER KITS AND ACCESSORIES (ORDER SEPARATELY)
RECEPTACLE

CIRCUIT BREAKER CONDUCTOR CONFIGURATION



K5400-520GR

5-20R Duplex GFI

20 Amp, 1 Pole

12 Awg



K5400-TT30

TT30R

30 Amp, 1 Pole

10 Awg



K5400-1450

14-50R

50 Amp, 2 Pole

8 Awg



K5400-BRIDGE-1POS

Self-grounded one position receptacle bridge with hardware



K5400-BRIDGE-2POS

Self-grounded two position receptacle bridge with hardware



K5415

Stabilizer Foot with hardware



K5035

Pad Mount Kit with hardware for U5138/39 pad mount pedestals required



K5T

5th Terminal for 208y / 120 volt 3-wire service



K5193

Bus kit to convert series-wired main breaker to parallel



K5194

Wire kit to convert parallel-wired main breaker to series



K3450

Telephone / CATV mounting bracket (mounts left or right



K5039

Penta bolt utility cover

GFI Rec.

• Up to two receptacle / circuit breaker kits can be field-installed in each powerhead. Order mounting bridge and
receptacle kits separately from above. For three receptacles or factory-installed kits, contact factory.
• Receptacle / circuit breaker kits include receptacle, circuit breaker, connected wire, cover plate and mounting
screws. Other receptacle / circuit breaker kits available.
• K5415 Stabilizer Foot sold separately. Recommended for double pedestals.
• Pad mount pedestals require K5035 pad mount kit. Order separately.
 Stock item – availability subject to prior sale.

Non-stock items – minimum order quantity required.
Utility requirements for this equipment may vary. Always consult the serving utility for their requirements before ordering or
installing equipment in this catalog.

G7

SECTION G

CATALOG #

SERVICE PEDESTALS

CATALOG NUMBER

G8

U5706 & U5707 TEMP TO FINAL SERVICE PEDESTAL–RINGLESS/RING TYPE

Concentric Knockouts
A (4) = 1, 1-1/2, 2, 2-1/2”
B (1) = 1-1/4, 1-1/2, 2”
C (1) = 3/4”, 1”
D (1) = 1/4”, 1/2”
E (1) = 1” Solid

Bridge Kit
(4) .173” Extr. Holes
E

A

B

C

A
30-3/16”

SERVICE PEDESTALS

A

SECTION G

A

19”

D

13-1/4”
8-1/2”

U5706-O-200P
* (Shown with (2) K5400-520GR receptacles,
K5400-BRIDGE-2POS & line side
conductor installed.)

OPEN

3-1/2”

SPECIFICATIONS
• 200 amp, 1∅, 120/240 volt, 22K AIC, underground service only.
• U5706 has Ringless meter socket available with or without horn bypass (-KK).
• U5707 has Ring type meter socket with MR-4 screw type meter ring.
• Suitable for use as service equipment, mobile home service equipment and temporary power
service equipment.
*• Provisions for up to two Type 3R in-use receptacle kits.
*• Order receptacle and bridge kits separately. See ordering information.
• Direct burial pedestal suitable for free standing or structure mounted installation.
• Separate line and load wireways are removable, lockable and sealable for security.
• Left side is for utility connection. Right side is for customer underground load exit.
• Convenient knockouts in post for thru-wall load exit requirements.
• Type 3R enclosure constructed with type G90 galvanized steel.
• Repaintable light gray polyester powder coat finish.
• Wire terminations accept copper or aluminum conductors: Line & Neutral: #6-350 Ground: (4) #14-1/0.
• Main circuit breaker can be series or parallel connected.
• Universal 4 circuit branch 125 amp interior (up to (2) 2-pole) accepts most manufacturers plug-in type
circuit breakers. See wiring diagram.
Utility requirements for this equipment may vary. Always consult the serving utility for their requirements before ordering or
installing equipment in this catalog.

G8

U5706 & U5707 TEMP TO FINAL SERVICE PEDESTAL–RINGLESS/RING TYPE

U5706 Ringless Pedestal
Catalog Number

Amps

Service

By-Pass

Main
Circuit Breaker

Main
Wired

Replacement
Main Type*

Branch
Circuits

Weight
LBS.

 U5706-O-200S

200

120/240

None

200a 2p

Series

UQFPH-M

4

79

 U5706-O-200S-KK

200

120/240

Horn

200a 2p

Series

UQFPH-M

4

79

U5707 Ring Type Pedestal
Catalog Number

Amps

Service

By-Pass

Main
Circuit Breaker

Main
Wired

Replacement
Main Type*

Branch
Circuits

Weight
LBS.

 U5707-O-200S

200

120/240

None

200a 2p

Series

UQFPH-M

4

79

G9

Up to two receptacle/circuit breaker kits can be field or factory installed. See below for ordering information. Contact factory for factory installed kits.

To increase pedestal height, order field-installed post extension kit K5708.
For field installed fifth terminal in the 9 oʼclock position, order kit K5T.
For field converting from parallel to series wired, order kit K5194. For field converting from series to parallel wired, order kit K5193.

Receptacle / Circuit Breaker Kits & Receptacle Bridge Kits
Amps/ Volts

NEMA Config

Circuit Breaker

Conductor

Configuration

 K5400-520GR

20a 120v

5-20R Duplex GFI

20a 1p

12 awg

Fig. 1

 K5400-620

20a 240v

6-20R Simplex

20a 2p

12 awg

Fig. 2

 K5400-620GB

20a 240v

6-20R Simplex

20a 240v GFI

12 awg

Fig. 3

 K5400-1450

50a 120/240v

14-50R

50a 120/240v

8 awg

Fig. 4

 K5400-1450GB

50a 120/240v

14-50R

50a 120/240v GFI

8 awg

Fig. 4
Fig. 5

 K5400-BRIDGE-2POS Self-grounded TWO position bridge with hardware and instructions.

Fig. 6

Receptacle kits include: receptacle, circuit breaker, connected wire, cover plate, mounting screws and instructions. Contact factory for other kits.
NOTE: Receptacle grounding is provided by metal contact with bridge and pedestal. Be sure to torque all fasteners per torque requirements.
 Stock item – availability subject to prior sale.
Non-stock items – minimum order quantity required.
Fig. 1
K5400-520GR

Fig. 5
K5400-BRIDGE-1POS

Fig. 2
K5400-620

Fig. 3
K5400-620GB

Fig. 6
K5400-BRIDGE-2POS

Fig. 4
K5400-1450

Fig. 7
UQFPH-M-200

Utility requirements for this equipment may vary. Always consult the serving utility for their requirements before ordering or
installing equipment in this catalog.

G9

SECTION G

 K5400-BRIDGE-1POS Self-grounded ONE position bridge with hardware and instructions.

SERVICE PEDESTALS

Catalog Number

MOBILE HOME REBUILD KITS

Catalog # 020-148-00-00-0
MPAP 200A interior rebuild kit

Catalog # 020-147-00-00-0
MPRV 100A interior rebuild kit

Catalog # RBK-1
Unicorn MPP (pre-1969)
interior rebuild kit

Catalog # Z1048284
MPAP, MPRV & Unicorn MPP
lug landing assembly with grounding kit

SECTION G

SERVICE PEDESTALS

G10

Above items sold as complete assemblies only. Individual components not available.
Utility requirements for this equipment may vary. Always consult the serving utility for their requirements before ordering or
installing equipment in this catalog.

G10

MOBILE HOME REBUILD KITS

Catalog # PF-KR
MPAP / MPRV rear connector kit

SERVICE PEDESTALS

Catalog # PF-BL
MPAP / MPRV blank deadfront
with hinged cover

G11

SECTION G

Lug cover for MPAP / MPRV
Order Catalog # 403456-SC
1
⁄
(8 2" W x 201⁄2" H) for 72" pedestals
and Cat. # 403457-SC (81⁄2" W x 261⁄2" H)
for 78" pedestals.

Utility requirements for this equipment may vary. Always consult the serving utility for their requirements before ordering or
installing equipment in this catalog.

G11

SERIES U5000–UNMETERED–SURFACE MOUNT POWER OUTLET

SECTION H

RV

H1

U5000-XL-75

SPECIFICATIONS:

















UL Listed 125 Amp, 120/240 Volt, 1∅ Power Outlet.
Short circuit current withstand rating 10K RMS symmetrical amperes.
Type 3R welded enclosure for durable outdoor use.
Enclosure constructed with galvanized 16 gauge steel.
ASA 61 grey polyester powder coat finish.
Convenient concentric knock-out configurations and mounting embosses.
Hub opening with closure plate allows for meter retrofit.
Wire terminations accept copper or aluminum conductors for loop feed wiring.
Line: (2) 1/0-#12
Ground: (2) 1/0-#14 & (4) #6-#14
Neutral: (2) 1/0-#14 & (4) #6-#14
Six circuit plated copper interior accepts standard plug-in type circuit breakers. Rated up to 125 amps.
Three position self-grounded receptacle bridge accepts most standard NEMA receptacles with mounting plates.
Components factory wired with stranded copper wire.
Lockable hinge cover and dead front are removable for installation and maintenance. Stay-open hinge cover has
safety interlock on dead front. Dead front cover must be removed before hinge cover can be removed.
Low wattage, 120 Volt fluorescent site light available. Factory or field installable.
Unit weight: 21 lbs.

Utility requirements for this equipment may vary. Always consult the serving utility for their requirements before ordering or
installing equipment in this catalog.

H1

SERIES U5000–UNMETERED–SURFACE MOUNT POWER OUTLET

H2

U5000 STANDARD MODELS
CATALOG #

RECEPTACLES

U5000-XL-41

(1) TT30R
(1) 5-20R GFI

(1) 30A, 1P, 120V
(1) 20A, 1P, 120V

U5000-XL-332

(2) TT30R
(1) 5-20R GFI

(2) 30A, 1P, 120V
(1) 20A, 1P, 120V

U5000-XL-55

(1) 14-50R
(1) 5-20R GFI

(1) 50A, 2P, 120/240V
(1) 20A, 1P, 120V

U5000-XL-75

(1) 14-50R
(1) TT30R
(1) 5-20R GFI

(1) 50A, 2P, 120/240V
(1) 30A, 1P, 120V
(1) 20A, 1P, 120V

(1) 14-50R
(1) TT30R
(1) 5-20R

(1) 50A, 2P, 120/240V
(1) 30A, 1P, 120V
(1) 20A, 1P, 120V, GFI

U5000-XL-75GB

CIRCUIT BREAKERS

U5000 STANDARD BASE MODEL

Base model without receptacles or circuit breakers.

RECEPTACLE & CIRCUIT BREAKER KITS
CATALOG #

RECEPTACLES

K5400-520GR

5-20R Duplex GFI

20 Amp, 1 Pole

12 Awg

GFI Rec.

5-20R Duplex

20 Amp, 1 Pole GFI

12 Awg

GFI CB

TT30R

30 Amp, 1 Pole

10 Awg

TT30R

30 Amp, 1 Pole GFI

10 Awg

14-50R

50 Amp, 2 Pole

8 Awg

K5400-520GB
K5400-TT30

K5400-TT30GB
K5400-1450

CIRCUIT BREAKERS

CONDUCTORS

CONFIGURATION

GFI CB

 Stock model. Availability subject to prior sale.
Note: 20 Amp GFI required at each RV site by UL and NEC 551-71

INTERNAL LIGHT KITS Factory or field installed. See accessory page.
Utility requirements for this equipment may vary. Always consult the serving utility for their requirements before ordering or
installing equipment in this catalog.

H2

SECTION H

U5000-XL

RV

Order up to (3) receptacle / breaker kits. Sold separately for field installation.
CATALOG #
DESCRIPTION

H3

SERIES U5100–METERED–SURFACE MOUNT POWER OUTLET

SECTION H

RV

Loop
feed not
available.

U5100-XL-75

SPECIFICATIONS




















UL Listed 125 Amp, 120/240 Volt—1∅ Power Outlet.
This is an overhead only unit.
Short circuit current withstand rating 10K RMS symmetrical amperes.
Type 3R welded enclosure for durable outdoor use.
Enclosure constructed with galvanized 16 gauge steel.
ASA 61 grey polyester powder coat finish.
Convenient concentric knock-out configurations and mounting embosses.
Hub opening with closure plate.
Wire terminations accept copper or aluminum conductors. Loop feed not available.
Line: (1) #6-250 kcmil Ground: (2) 1/0-#14 & (4) #6-#14 Neutral: (2) 1/0-#14 & (4) #6-#14
Six circuit plated copper interior accepts standard plug-in type circuit breakers. Rated up to 125 amps.
Three position self-grounded receptacle bridge accepts most standard NEMA receptacles with mounting plates.
Four terminal, drawn ring type meter socket with aluminum sealing ring. Ringless meter socket available. Use
U5101 prefix.
Components factory wired with stranded copper wire.
Lockable hinge cover and dead front are removable for installation and maintenance. Stay-open hinge cover has
safety interlock on dead front. Dead front must be removed before hinge cover can be removed.
Low wattage, 120 Volt fluorescent site light available. Factory or field installable.
Unit weight: 26 lbs.
Utility requirements for this equipment may vary. Always consult the serving utility for their requirements before ordering or
installing equipment in this catalog.

H3

SERIES U5100–METERED–SURFACE MOUNT POWER OUTLET

H4

U5100 STANDARD MODELS
CATALOG #

RECEPTACLES

CIRCUIT BREAKERS

U5100-XL-41

(1) TT30R
(1) 5-20R GFI

(1) 30A, 1P, 120V
(1) 20A, 1P, 120V

U5100-XL-55

(1) 14-50R
(1) 5-20R GFI

(1) 50A, 2P, 120/240V
(1) 20A, 1P, 120V

U5100-XL-75

(1) 14-50R
(1) TT30R
(1) 5-20R GFI

(1) 50A, 2P, 120/240V
(1) 30A, 1P, 120V
(1) 20A, 1P, 120V

U5100-XL-75GB

(1) 14-50R
(1) TT30R
(1) 5-20R

(1) 50A, 2P, 120/240V
(1) 30A, 1P, 120V
(1) 20A, 1P, 120V, GFI

U5100-XL-552GR

(2) 14-50R
(1) 5-20R GFI

(2) 50A, 2P, 120/240V
(1) 20A, 1P, 120V, GFI

U5100 STANDARD BASE MODELS
Order up to (3) receptacle / breaker kits. Sold separately for field installation.
CATALOG #
DESCRIPTION

U5101-XL

Ringless-type base model without receptacles or circuit breakers.

RECEPTACLE & CIRCUIT BREAKER KITS
CATALOG #

RECEPTACLES

K5400-520GR

5-20R Duplex GFI

20 Amp, 1 Pole

12 Awg

GFI Rec.

5-20R Duplex

20 Amp, 1 Pole GFI

12 Awg

GFI CB

TT30R

30 Amp, 1 Pole

10 Awg

TT30R

30 Amp, 1 Pole GFI

10 Awg

14-50R

50 Amp, 2 Pole

8 Awg

K5400-520GB
K5400-TT30

K5400-TT30GB
K5400-1450

CIRCUIT BREAKERS

CONDUCTORS

CONFIGURATION

GFI CB

 Stock model. Availability subject to prior sale.
Note: 20 Amp GFI required at each RV site by UL and NEC 551-71

INTERNAL LIGHT KITS Factory or field installed. See accessory page.
Utility requirements for this equipment may vary. Always consult the serving utility for their requirements before ordering or
installing equipment in this catalog.

H4

SECTION H

Ring-type base model without receptacles or circuit breakers.

RV

U5100-XL

SERIES U5200–UNMETERED–PEDESTAL POWER OUTLET

SECTION H

RV

H5

U5200-XL-75
DIRECT BURIAL

SPECIFICATIONS



















UL Listed 125 Amp, 120/240 Volt—1∅ Power Outlet.
Short circuit current withstand rating 10K RMS symmetrical amperes.
Type 3R welded enclosure for durable outdoor use.
Enclosure constructed with galvanized 16 gauge steel.
Direct burial or pad mounted post constructed with 14 gauge galvanized steel. Two removable front covers for
ease of installation. Accepts up to (3) 2 1/2” conduits.
ASA 61 grey polyester powder coat finish.
Convenient concentric knock-out configurations. See note A & B above.
Hub opening with closure plate allows for meter retrofit.
Wire terminations accept copper or aluminum conductors for loop feed wiring.
Line: (2) #6-350 kcmil
Ground: (2) #14-2/0
Neutral: (2) #6-350 kcmil
Six circuit plated copper interior accepts standard plug-in type circuit breakers. Rated up to 125 amps.
Three position self-grounded receptacle bridge accepts most standard NEMA receptacles with mounting plates.
Components factory wired with stranded copper wire.
Lockable hinge cover and dead front are removable for installation and maintenance. Stay-open hinge cover has
safety interlock on dead front. Dead front must be removed before hinge cover can be removed.
Low wattage, 120 Volt fluorescent site light available. Factory or field installable.
Unit weight: Single–48 lbs. Double–70 lbs.
Utility requirements for this equipment may vary. Always consult the serving utility for their requirements before ordering or
installing equipment in this catalog.

H5

SERIES U5200–UNMETERED–PEDESTAL POWER OUTLET

H6

U5200 STANDARD MODELS
SINGLE HEAD
CATALOG #

DBL. HEAD
CATALOG#

U5200-XL-41

U5220-XL-41

U5200-XL-41GB
U5200-XL-332

U5200-XL-75

U5220-XL-75

U5200-XL-75GB

RECEPTACLES

CIRCUIT BREAKERS

(1) TT30R
(1) 5-20R GFI

(1) 30A, 1P, 120V
(1) 20A, 1P, 120V

(1) TT30R
(1) 5-20R

(1) 30A, 1P, 120V
(1) 20A, 1P, 120V, GFI

(2) TT30R
(1) 5-20R GFI

(2) 30A, 1P, 120V
(1) 20A, 1P, 120V

(1) 14-50R
(1) TT30R
(1) 5-20R GFI

(1) 50A, 2P, 120/240V
(1) 30A, 1P, 120V
(1) 20A, 1P, 120V

(1) 14-50R
(1) TT30R
(1) 5-20R

(1) 50A, 2P, 120/240V
(1) 30A, 1P, 120V
(1) 20A, 1P, 120V,GFI

U5200 STANDARD BASE MODELS
Order up to (3) receptacle / breaker kits. Sold separately for field installation.
CATALOG #
DESCRIPTION
Single head base model on direct burial post.

U5210-XL

Single head base model on pad mount post. Order K5410 pad mount base separately.

U5220-XL

Double head base model on direct burial post.

U5230-XL

Double head base model on pad mount post. Order K5410 pad mount base separately.

RV

U5200-XL

CATALOG #

RECEPTACLES

K5400-520GR

5-20R Duplex GFI

20 Amp, 1 Pole

12 Awg

GFI Rec.

5-20R Duplex

20 Amp, 1 Pole GFI

12 Awg

GFI CB

TT30R

30 Amp, 1 Pole

10 Awg

TT30R

30 Amp, 1 Pole GFI

10 Awg

14-50R

50 Amp, 2 Pole

8 Awg

K5400-520GB
K5400-TT30

K5400-TT30GB
K5400-1450

CIRCUIT BREAKERS

CONDUCTORS

CONFIGURATION

GFI CB

 Stock model. Availability subject to prior sale.
Note: 20 Amp GFI required at each RV site by UL and NEC 551-71

INTERNAL LIGHT KITS Factory or field installed. See accessory page.
Utility requirements for this equipment may vary. Always consult the serving utility for their requirements before ordering or
installing equipment in this catalog.

H6

SECTION H

RECEPTACLE & CIRCUIT BREAKER KITS

H7

SERIES U5300–METERED–PEDESTAL POWER OUTLET

SECTION H

RV

U5310-O-75
PAD MOUNT

DIRECT BURIAL

SPECIFICATIONS


















UL Listed 125 Amp, 120/240 Volt—1∅ Power Outlet.
Short circuit current withstand rating 10K RMS symmetrical amperes.
Type 3R welded enclosure for durable outdoor use.
Enclosure constructed with galvanized 16 gauge steel.
Direct burial or pad mounted post constructed with 14 gauge galvanized steel. Two removable front covers for
ease of installation. Accepts up to (3) 2 1/2” conduits.
ASA 61 grey polyester powder coat finish.
Wire terminations accept copper or aluminum conductors for loop feed wiring.
Line: (2) #6-350 kcmil
Ground: (2) #14-2/0
Neutral: (2) #6-350 kcmil
Six circuit plated copper interior accepts standard plug-in type circuit breakers. Rated up to 125 amps.
Three position self-grounded receptacle bridge accepts most standard NEMA receptacles with mounting plates.
Four terminal, drawn ring type meter socket with aluminum sealing ring.
Components factory wired with stranded copper wire.
Lockable hinge cover and dead front are removable for installation and maintenance. Stay-open hinge cover has
safety interlock on dead front. Dead front must be removed before hinge cover can be removed.
Low wattage, 120 Volt fluorescent site light available. Factory or field installable.
Unit weight: Single–53 lbs. Double–80 lbs.

Utility requirements for this equipment may vary. Always consult the serving utility for their requirements before ordering or
installing equipment in this catalog.

H7

SERIES U5300–METERED–PEDESTAL POWER OUTLET

H8

U5300 STANDARD MODELS
SINGLE HEAD
CATALOG #

DBL. HEAD
CATALOG#

RECEPTACLES

CIRCUIT BREAKERS

U5300-O-41

(1) TT30R
(1) 5-20R GFI

(1) 30A, 1P, 120V
(1) 20A, 1P, 120V

U5300-O-55

(1) 14-50R
(1) 5-20R GFI

(1) 50A, 2P, 120/240V
(1) 20A, 1P, 120V

(1) 14-50R
(1) TT30R
(1) 5-20R GFI

(1) 50A, 2P, 120/240V
(1) 30A, 1P, 120V
(1) 20A, 1P, 120V

(2) 14-50R
(1) 5-20R GFI

(2) 50A, 2P, 120/240V
(1) 20A, 1P, 120V

U5300-O-75

U5320-O-75

U5300-O-552GR

U5300 STANDARD BASE MODELS
Order up to (3) receptacle / breaker kits. Sold separately for field installation.

U5300-O

Single head base model on direct burial post.

U5310-O

Single head base model on pad mount post. Order K5410 pad mount base separately.

U5320-O

Double head base model on direct burial post.

U5330-O

Double head base model on pad mount post. Order K5410 pad mount base separately.

RECEPTACLE & CIRCUIT BREAKER KITS
CATALOG #

RECEPTACLES

K5400-520GR

5-20R Duplex GFI

20 Amp, 1 Pole

12 Awg

GFI Rec.

5-20R Duplex

20 Amp, 1 Pole GFI

12 Awg

GFI CB

TT30R

30 Amp, 1 Pole

10 Awg

TT30R

30 Amp, 1 Pole GFI

10 Awg

14-50R

50 Amp, 2 Pole

8 Awg

K5400-520GB
K5400-TT30

K5400-TT30GB
K5400-1450

CIRCUIT BREAKERS

CONDUCTORS

CONFIGURATION

GFI CB

 Stock model. Availability subject to prior sale.
Note: 20 Amp GFI required at each RV site by UL and NEC 551-71
INTERNAL LIGHT KITS Factory or field installed. See accessory page.
Utility requirements for this equipment may vary. Always consult the serving utility for their requirements before ordering or
installing equipment in this catalog.

H8

SECTION H

DESCRIPTION
RV

CATALOG #

H9

MILBANK UTILITY GRADE 125 AMP
DRAWN RING TYPE METER SOCKET

REMOVABLE DEADFRONT

TAMPER PROOF BARRIER BETWEEN
RECEPTACLES & BREAKERS

STANDARD COPPER
FACTORY WIRING ON ALL
RECEPTACLES AND
CIRCUIT BREAKERS

RECEPTACLES MOLDED
FROM DURABLE NYLON
MATERIAL

SIX CIRCUIT 125 AMP INTERIOR WITH PLATED
COPPER STABS & GLASS FILLED C/B BASE

LOW WATTAGE
FLUORESCENT
LIGHT
(OPTIONAL)

RV

GLASS FILLED LUG LANDING WITH
TWIN #6-350 KCMIL LINE CONNECTORS
FOR LOOP FEED WIRING

LEFT & RIGHT LOCKING COVER PROVISIONS

OPTIONAL LEFT OR RIGHT INSTALLATION
PHOTO-ELECTRIC LIGHT CONTROL

PAD LOCKABLE DEADFRONT PROVISION

GFI RECEPTACLE WITH MISWIRE / TRIP
INDICATOR LIGHT

SELF-GROUNDED UNIVERSAL BRIDGE FOR UP
TO THREE RECEPTACLES

INSULATED BONDABLE MULTIPLE
HOLE NEUTRAL BAR

MULTIPLE HOLE GROUNDING BAR

MILLENNIUM SERIES BY MILBANK

SECTION H
H9
MILLENNIUM FEATURES

H10
ROLLED EDGE WIREWAY
(NO SHARP EDGES)

SLIP-ON LOCKING TABS FOR
LOWER COVER

STAINLESS STEEL LOCKING
HASP& SEALING SCREW

SECTION H

REMOVABLE HINGE
COVER
WITH STAY OPEN &
CLOSED SNAPS

RV

LIGHT LENS
(OPTIONAL)

U5300-O-75
(Illustrated)

ONE PIECE WELDED POST
CONSTRUCTION

EASY TWO SCREW LOWER COVER REMOVAL

TWIN #14-2/0 GROUND LUG

MILLENNIUM FEATURES

H10

H11

600 / 1200 AMP–PAD MOUNTED PANEL BOARD–120 / 240 VOLT–1∅

SPECIFICATIONS





SECTION H

RV





600 to 1200 amp, 120/240 Volt, 1∅ distribution bus accepts up to (6) 2 pole, 200 amp circuit breakers. Order from chart below.
Costly main breaker not required per NEC 230-71.
Economical alternative to costly wall hung or strut-mounted panel boards and load centers.
Low profile, aesthetic design can be located near utility transformers or fed from a main service to a convenient location.
Pad mounted Type 3R powder coated aluminum enclosure – Standard color is gray.
Hinge door and lift off rear service door are lockable and sealable for security.
NOTE: Consult local code enforcement for pad size requirements. Order Catalog # CP-24-PDMNT-CALT pad mount base or
Catalog # CP-ABK5/8 anchor bolt kit separately.

CIRCUIT BREAKERS
CATALOG #
CP3B-AUX-1200

AMPS

PHASE

VOLTS

1200

1∅

120/240

LINE CONNECTORS
(3) 1-600 kcmil / ∅ or
(3) 2-250 kcmil / ∅

D

W

H

17"

24"

41"

200 AMP FRAME—PLUG-IN—10K AIC & 22K AIC
TWO-POLE—COMMON TRIP

UQFP

WIRE RANGE

2-POLE
RATING

10K AIC
PLUG-IN

22K AIC
PLUG-IN

PKG
QTY

CU

AL

100

UQFP-100

UQFPH-100

1

#3-#1

#1-1/0

125

UQFP-125

UQFPH-125

1

#3-#1

#1-1/0

150

UQFP-150

UQFPH-150

1

1/0-300

2/0-300

175

UQFP-175

UQFPH-175

1

1/0-300

2/0-300

200

UQFP-200

UQFPH-200

1

1/0-300

2/0-300

225

UQFP-225

UQFPH-225

1

1/0-300

2/0-300

Utility requirements for this equipment may vary. Always consult the serving utility for their requirements before ordering or
installing equipment in this catalog.

H11

100, 200 & 400 AMP–TERMINAL BOX–1∅ & 3∅–120 / 240 VOLT–600 VAC

H12

U4540-XL

RV

SECTION H

U4548
U4549

U4540
U4542

100, 200, & 400 AMP—TERMINAL BOXES—1∅ & 3∅—120/240 VOLT
PHASE AMPS
1

100

VOLTS
120/240

CATALOG
NUMBER

HUB

U4544-XL

C.P.

CONNECTORS 1∅ TO
CU7AL
3∅ KIT
(6) #12-1/0

K4543

3

100

600

U4546-XL

C.P.

(6) #12-1/0

N/A

1

200

120/240

U4540-XL

C.P.

(6) #6-350

K4539

3
1
3

200
400
400

600
120/240
600

U4542-XL
U4548-RXL
U4549-RXL

C.P.

(6) #6-350

N/A

C.P.

(3) #6-350 or
(2) #4-600
(3) #6-350 or
(2) #4-600

K4547

C.P.

N/A

DIMENSIONS
D"

W"

41⁄8 913⁄16

CONCENTRIC K.O.ʼS

H"

1

2

3

4

5

18

—

2

2

1

1 1
4, 2

⁄ ⁄

13

⁄8 9 ⁄16 18

—

2

2

1

1 1
4, 2

41⁄8 1413⁄16 23

—

11⁄4

21⁄2

21⁄2

1 1
4, 2

—

1

1

1

1 1
4, 2

1

4

1

14

5

151⁄2

4

⁄8

5

13

15

⁄16 23

1

27

⁄2 27

3
3

1

⁄4

3
3

2

⁄2

2

⁄2

⁄ ⁄
⁄ ⁄
⁄ ⁄

3

1 1
4, 2

⁄ ⁄

1

3

1 1
4, 2

1

⁄ ⁄

⁄4
⁄4

HUB: Standard hub opening on top with closing plate attached.
FEATURES: UL Listed pad lockable Type 3R enclosure.
3∅ 120/240V APPLICATION: Field installable 3∅ lug kit converts 1∅ unit to 3∅ unit.

Utility requirements for this equipment may vary. Always consult the serving utility for their requirements before ordering or
installing equipment in this catalog.

H12

H13

LIGHTING ACCESSORIES

INTERNAL LIGHT KITS FOR POWER OUTLETS
Application:
• Internal light kit for U5000 & U5200 UNMETERED power outlets.
Features:
• Includes 5 watt fluorescent lamp socket, ballast, lamp shield and
opaque hinge cover lens. Factory wired to 20 amp GFI circuit. May
be wired to separate 20 amp circuit breaker. Order Q120
separately.
• Cover on unmetered power outlet is 19 1/8” in height.
Ordering:
• Order with -L suffix (after catalog number) for factory installed.
• Order catalog number K5411 for field installed.

Application:
• Internal light kit for U5100 & U5300 METERED power outlets.
Features:
• Includes 5 watt fluorescent lamp socket, ballast, lamp shield and
opaque hinge cover lens. Factory wired to 20 amp GFI circuit. May
be wired to separate 20 amp circuit breaker. Order Q120
separately.
• Cover on metered power outlet is 15 1/4” in height.
Ordering:

SECTION H

RV

• Order with -L suffix (after catalog number) for factory installed.
• Order catalog number K5412 for field installed.

PHOTOELECTRIC LIGHT CONTROL KIT
Application:
• Photoelectric light control kit for K5411 & K5412
light kits.
Features:
• 2.5 amp, 120 Volt photo electrical control wired in
series with K5411& K5412 light kits.
Ordering:
• Order with -LPC suffix for factory installed light and
PE control.
• Order catalog number K5413 for field installed.

WARNING: Always disconnect power
prior to installing these devices.
Utility requirements for this equipment may vary. Always consult the serving utility for their requirements before ordering or
installing equipment in this catalog.

H13

TELECOMMUNICATIONS AND PEDESTAL ACCESSORIES

H14

TELEPHONE AND CABLE TV KIT
Application:
• Mounts to rear of pedestal series U5200 & U5300. May also be
adaptable to a wooden or similar structure.
Features:
• Single: 16” galvanized raceway, (1) RJ11 telephone jack
& (1) Type F coaxial CATV jack.
• Dual: 16” galvanized raceway, (2) RJ11 telephone jack
& (1) Type F coaxial CATV jack.
• Includes mounting hardware & instructions.
Ordering:
• Single Line Telephone & Cable TV kit order
catalog number K4709-02.
• Weatherproof Type 3R “in-use” cover available. Add -3R to
catalog numbers above.
NOTE:
• Confirm acceptability with Cable TV & Telephone provider
before ordering or installing these devices.

K4709-02
K4709-02-3R

RV

Application:
• Used to cover water pipe and provide means to
mount hose bib to rear of pedestal.
Features:
• Includes mounting hardware and instructions.
• Matches K4709 kits when mounted side by side.

10
16 OD

Ordering:
• Order catalog number K4709-WS.

13 5/16

4

3 5/32 ID

2 1/2 OD

3 3/4
4 9/32 OD ref

Utility requirements for this equipment may vary. Always consult the serving utility for their requirements before ordering or
installing equipment in this catalog.

H14

SECTION H

WATER SHROUD WITH HARDWARE

H15

PEDESTAL MOUNTING ACCESSORIES

FIELD INSTALLED PAD MOUNT KIT
Application:
• Field installed pad mount kit with (6) 3/4” mounting holes.
Features:
• Includes 1/4-20 stainless steel hardware to attach pad mount
base to post.
• Anchor bolt kit sold separately (order catalog number K5421).
Ordering:
• Order catalog number K5410.

STABILIZER FOOT WITH HARDWARE

SECTION H

RV

Application:
• Stabilizes direct burial type posts in unstable soil conditions.
Features:
• Includes 1/4-20 hardware to attach to U5200 & U5300 pedestals.
Ordering:
• Order catalog number K5415.

ANCHOR BOLT KIT
Application:
• Concrete anchor bolt kit designed to attach pad
mount base to concrete.
Features:
• (4) sets of zinc-plated 5/8-11 x 10” bolt with 2” toe.
• Includes nut and flat washer.
Ordering:
• Order catalog number K5421.

Utility requirements for this equipment may vary. Always consult the serving utility for their requirements before ordering or
installing equipment in this catalog.

H15

METERING & SINGLE RECEPTACLE ACCESSORIES

H16

FIELD INSTALLED METER KITS
Application:
• Field installed meter kit for U5000 & U5200 power outlets.
Features:
• 100 amp cast meter socket, CL200 E-Z Read Meter, sealing ring,
security seal, 1” Milbank hub, nipple and mounting screws.
• Optional 1” liquid-tight hub available for existing units without
extruded hub opening. See ordering information.
• See CL200 for Watt-hour meter specifications.
Ordering:
• Order catalog number K4800-01.

E-Z READ WATT-HOUR METER
Application:
• 200 Amp E-Z read watt-hour meter designed to be field installed
on the U5100 & U5300 metered power outlets.
Features:
• 200 Amp Form 2S 120/240 Volt.
• Numeric read-out in full kilowatt increments. No “tenths” dial.

• Order catalog number CL200. Sold in multiples of (4) per carton.

*SINGLE RECEPTACLE ONLY POWER OUTLET
Application:
• Overhead/underground power outlet receptacle, suitable for RV,
temporary service, campground, marina & boatyard equipment.
Features:
• Type 3R, 120/240 Volt single phase.
• Lockable cover.
Ordering:
• Order catalog number from chart below.

WARNING: Always disconnect power
prior to installing these devices.
Utility requirements for this equipment may vary. Always consult the serving utility for their requirements before ordering or
installing equipment in this catalog.

H16

SECTION H

Ordering:

RV

• Remanufactured to 1% accuracy.

H17

RV REPLACEMENT PARTS & ACCESSORIES

708080-MO
20 amp GFI receptacle
NEMA 520

K5400-520GR
20 amp 120V GFI receptacle and
circuit breaker kit

K5400-520GB
20 amp 120V receptacle
and GFI circuit breaker kit

701776-MO
30 amp receptacle
NEMA TT30

SECTION H

RV

K5400-TT30
30 amp 120V receptacle
and circuit breaker kit

K5400-1450
50 amp 120 / 240V
receptacle and circuit
breaker kit

K5400-BRIDGE
Receptacle bridge (3) position

708767-MO
50 amp receptacle
NEMA 1450

K5400-NEUTRAL
Neutral assembly

K5400-BLANK

Utility requirements for this equipment may vary. Always consult the serving utility for their requirements before ordering or
installing equipment in this catalog.

H17

RV REPLACEMENT PARTS & ACCESSORIES

H18

Z917602-AC
Circuit breaker base
(6 circuit)

Z918466-AC
Lug landing base
Z915141-AC
Left or right
meter block assembly

Q120
20 amp 1 pole
circuit breaker

SEALING RING

SNAP ACTION
MR-2

RV

708784-MO
20 amp 1 pole GFI
circuit breaker

SECTION H

Q130
30 amp 1 pole
circuit breaker

HINGE COVER
Z918449-SC
19” Unmetered
Z918447-SC
15” Metered

Q250
50 amp 2 pole
circuit breaker

DEADFRONT
Z818052-SC 19” Unmetered
Z818480-SC 15” Metered

Utility requirements for this equipment may vary. Always consult the serving utility for their requirements before ordering or
installing equipment in this catalog.

H18

H19

RV PRODUCT INFORMATION–WIRING DIAGRAM LABEL–WARRANTY

U5300-O SERIES
RATING: 125 amps maximum–120/240 VAC–1∅3W
METER SOCKET: 100 amp continuous–600 VAC–Rainproof NEMA
Type 3R

Size of field installed conductors shall be 60°, 75°, or
90°C sized to 60°C rating for 110 Amps or less, and
75° C or 90°C sized to 75° C
for 125 Amps and above.

SHORT CIRCUIT CURRENT RATING: 10,000 RMS symmetrical
amperes at 240 VAC maximum, but is limited to the lowest short
circuit current rating of any installed circuit breaker. Watthour
meter not included in short circuit current rating.
REPLACEMENT CIRCUIT BREAKER: Must be the same type and
rating. Use Milbank: UCP; Siemens/ITE: QP, QT; Cutler-Hammer
/Westinghouse: QP, BD, BR; General Electric: TQ, THQ, THQL;
Challenger: C, Q, QC, QP, A.

FOR
UNDERGROUND
FEED ONLY

SUITABLE FOR USE AS: Service equipment, mobile home service
equipment, temporary power service equipment and recreational
vehicle site supply power. See rating label below.

WIRE TERMINAL INFORMATION—USE AL-CU CONDUCTORS
TERMINAL

WIRE RANGE

TORQUE LB. / IN.

Twin
350 kcmil - #6

250

Load, Neutral
and
Ground

(large hole)

14 - 10
8
6-4
3 - 1/0

35
40
45
50

Load, Neutral
and
Ground

(small hole)

14 - 10
8
6

20
25
35

DANGER

On

Hazard of Electrical Trip
Shock or Burn
TURN OFF POWER Off
Supplying this equipment To reset breaker
move to “off”
before working inside
then to “on”

SECTION H

RV

Line & Neutral

RECEPTACLE
KIT

RV

K5400-520GR
K5400-520GB
K5400-TT30
K5400-TT30GB
K5400-1450
K5400-BLANK

R
R
A
A
A
A

A = Acceptable
R = Required
 K5400-520GR or
K5400-520GB required

Shipping tends to
loosen bolted
connections.
Check and tighten
all hardware before
energizing unit.

WARRANTY


If any equipment manufactured by seller fails due to defects in material or workmanship within one year from the date seller shipped the
equipment, such equipment will be replaced or repaired at seller’s option. This warranty is limited to the repair or replacement of the
equipment or component part or parts of the equipment and becomes void if any equipment failure is due to improper installation, purchaser’s
negligence, unreasonable use, damage (not resulting from defects in material or workmanship) or misapplication. This warranty does not
include reimbursement for the expense of installation, removal of the equipment from the line, transportation, or any other expenses which
may be incurred.



In no event shall seller be liable for consequential or incidental damages and seller’s liability for any and all losses and damages sustained by
the purchaser or any other person arising out of or by reason of the use of the equipment, a defect in the equipment (whether discoverable or
latent), a claim of negligence or for any other reason, shall not exceed the purchase price paid by the purchaser.



THIS WARRANTY IS MADE EXPRESSLY IN LIEU OF ANY OTHER WARRANTY AND SELLER MAKES NO OTHER REPRESENTATION OR
WARRANTY OF ANY OTHER KIND, EXPRESS OR IMPLIED, WITH RESPECT TO THE EQUIPMENT, WHETHER AS TO MERCHANTABILITY,
FITNESS FOR A PARTICULAR PURPOSE OR ANY OTHER MATTER.



AUTHORIZATION MUST BE OBTAINED FROM MILBANK’S GENERAL OFFICE BEFORE EQUIPMENT IS RETURNED.

Utility requirements for this equipment may vary. Always consult the serving utility for their requirements before ordering or
installing equipment in this catalog.

H19

U4908/U4909 UNDERGROUND SERVICE POWER OUTLET–RINGLESS/RING TYPE

I1

25 15/16

MILBANK

5 3/8

CL
MILBANK

3 5/16

9”
5 1/4
1 5/8

U4909-O-11GR
3
4

3
4


















Utility requirements for this equipment may vary. Always consult the serving utility for their requirements before ordering or
installing equipment in this catalog.

I1

SECTION I



Available in ringless style (U4908 series) or ring type (U4909 series)
UL Listed 100 Amp, 120/240 Volt – 1∅ Underground Service Power Outlet
Short circuit current withstand rating 10K RMS symmetrical amperes
Type 3R welded enclosure for durable outdoor use
Enclosure constructed with galvanized 16 gauge steel
ASA 61 grey polyester powder coat finish
Convenient concentric knock-out configurations and mounting embosses
Wire terminations accept copper or aluminum conductors
Service–Line & Neutral: (1) #6-2/0 Load Ground: (2) 1/0-#14 & (4) #6-#14
Load Neutral: (2) 1/0-#14 & (4) #6-#14 Service Ground: #2-#8
Six circuit plated copper interior accepts standard plug-in type circuit breakers
Three position self-grounded receptacle bridge accepts most standard NEMA receptacles with mounting plates
Four terminal, ringless meter socket with stainless steel locking hasp. Ring type socket has aluminum MR-2 snap
action sealing ring
Lockable hinge cover and deadfront are removable for installation and maintenance. Stay-open hinge cover has
safety interlock on deadfront. Deadfront must be removed before hinge cover can be removed.
Tamper proof fastening available

TEMPORARY POWER

SPECIFICATIONS

I2

U4908/U4909 UNDERGROUND SERVICE POWER OUTLET–RINGLESS/RING TYPE

U4908 / U4909 STANDARD CONFIGURATIONS

ORDERING INFORMATION
CATALOG #

SOCKET TYPE

 U4908-O

Ringless

DESCRIPTION
Order base model and up to three factory installed receptacle/breaker kit separately

TEMPORARY POWER

from list below. Other kits available. Consult factory.
 U4908-O-11GR

Ringless

 U4908-O-55GBGR

Ringless

 U4909-O

Ring type

Order base model and up to three factory installed receptacle/breaker kit separately
from list below. Other kits available. Consult factory.

 U4909-O-11GR

Ring type

 U4909-O-55GBGR

Ring type

SECTION I

RECEPTACLE & CIRCUIT BREAKER KITS
CATALOG
NUMBER

AMP

BLADE

VOLTAGE

NEMA
CONFIG.

TYPE

 K5400-520

20

Straight

120

5-20

Std. Duplex

20 Amp 1 Pole

 K5400-520GR

20

Straight

120

5-20

GFI Duplex

20 Amp 1 Pole

 K5400-620

20

Straight

240

6-20

Single

20 Amp 2 Pole

 K5400-620GB

20

Straight

240

6-20

Single

20 Amp 2 Pole GFI

 K5400-1450

50

Straight

120/240

14-50

Single

30 Amp 2 Pole

 K5400-1450GB

50

Straight

120/240

14-50

Single

30 Amp 2 Pole GFI

CIRCUIT BREAKER TYPE

Flat cover may not close completely with twist locking devices in use.
Order slope-front 3R cover # 1107681 separately to use with twist lock type receptacles.
 Stock item – availability subject to prior sale.
Non-stock items – minimum order quantity required

Utility requirements for this equipment may vary. Always consult the serving utility for their requirements before ordering or
installing equipment in this catalog.

I2

SERIES U5000–UNMETERED–SURFACE MOUNT POWER OUTLET

I3

U5000-XL-38GR

TEMPORARY POWER

SPECIFICATIONS:
















UL Listed 125 Amp, 120/240 Volt, 1∅ Power Outlet.
Short circuit current withstand rating 10K RMS symmetrical amperes.
Type 3R welded enclosure for durable outdoor use.
Enclosure constructed with galvanized 16 gauge steel.
ASA 61 grey polyester powder coat finish.
Convenient concentric knock-out configurations and mounting embosses.
Hub opening with closure plate installed.
Wire terminations accept copper or aluminum conductors for loop feed wiring.
Line: (2) 1/0-#12
Ground: (2) 1/0-#14 & (4) #6-#14
Neutral: (2) 1/0-#14 & (4) #6-#14
Six circuit plated copper interior accepts standard plug-in type circuit breakers.
Three position self-grounded receptacle bridge accepts most standard NEMA receptacles with mounting plates.
Components factory wired with stranded copper wire.
Lockable hinge cover and dead front are removable for installation and maintenance. Stay-open hinge cover
has safety interlock on dead front. Dead front cover must be removed before hinge cover can be removed.
NOTE: Cover may not close completely with twist-locking devices in use.
Tamper proof fastening available.

Utility requirements for this equipment may vary. Always consult the serving utility for their requirements before ordering or
installing equipment in this catalog.

I3

SECTION I



I4

SERIES U5000–UNMETERED–SURFACE MOUNT POWER OUTLET

SECTION I

TEMPORARY POWER

U5000 STANDARD CONFIGURATIONS

ORDERING INFORMATION
CATALOG #

DESCRIPTION

U5000-XL-(*)

(*) Add suffix from above chart to complete catalog number (ie: U5000-XL-11GR)

U5000-XL

Order base model and up to three factory installed receptacle/breaker kit separately from list
below. Other kits available. Consult factory.

RECEPTACLE & CIRCUIT BREAKER KITS
CATALOG

NEMA

NUMBER

AMP

BLADE

VOLTAGE

CONFIG.

TYPE

CIRCUIT BREAKER TYPE

K5400-520

20

Straight

120

5-20

Std. Duplex

20 Amp 1 Pole

K5400-520GR

20

Straight

120

5-20

GFI Duplex

20 Amp 1 Pole

K5400-620

20

Straight

240

6-20

Single

20 Amp 2 Pole

K5400-620GB

20

Straight

240

6-20

Single

20 Amp 2 Pole GFI

K5400-1450

50

Straight

120/240

14-50

Single

30 Amp 2 Pole

K5400-1450GB

50

Straight

120/240

14-50

Single

30 Amp 2 Pole GFI

* Cover may not close completely while in use with Twist-Locking devices.

Utility requirements for this equipment may vary. Always consult the serving utility for their requirements before ordering or
installing equipment in this catalog.

I4

SERIES U5001–UNMETERED–SURFACE MOUNT POWER OUTLET

TEMPORARY POWER

U5001-RL-01

SPECIFICATIONS:











UL Listed 125 Amp, 120/240 Volt, 1∅ Power Outlet.
Short circuit current withstand rating 10K RMS symmetrical amperes.
Type 3R welded enclosure for durable outdoor use.
ASA 61 grey polyester powder coat finish.
Wire terminations accept copper or aluminum conductors.
Line: 1/0-#4
Ground/Neutral: (4) 1/0-#14 & (11) #14-#6
Six circuit plated copper interior accepts standard plug-in type circuit breakers.
Components factory wired with stranded copper wire.
Lockable hinge cover and dead front are removable for installation and maintenance.
U5001-RL-01 includes:
(1) L6-30
(1) 30A, 2P, 240V GFI Breaker
(2) L5-20
(2) 20A, IP, 120V GFI Breaker

Utility requirements for this equipment may vary. Always consult the serving utility for their requirements before ordering or
installing equipment in this catalog.

I5

SECTION I



I5

SECTION I

TEMPORARY POWER

I6

SERIES U5100 & U5101–OVERHEAD–RING & RINGLESS–
METERED–SURFACE MOUNT POWER OUTLET

U5100-XL-11GR

SPECIFICATIONS



















Available in ringless style (U5101 series) or ring type (U5100 series).
UL Listed 125 Amp, 120/240 Volt—1∅ Power Outlet.
Short circuit current withstand rating 10K RMS symmetrical amperes.
Type 3R welded enclosure for durable outdoor use.
Enclosure constructed with galvanized 16 gauge steel.
ASA 61 grey polyester powder coat finish.
Convenient concentric knock-out configurations and mounting embosses.
Hub opening with closure plate installed.
Wire terminations accept copper or aluminum conductors.
Line: (1) #6-250 kcmil Ground: (2) 1/0-#14 & (4) #6-#14 Neutral: (2) 1/0-#14 & (4) #6-#14
Six circuit plated copper interior accepts standard plug-in type circuit breakers.
Three position self-grounded receptacle bridge accepts most standard NEMA
receptacles with mounting plates.
Four terminal, ringless meter socket with stainless steel locking hasp.
Components factory wired with stranded copper wire.
Lockable hinge cover and dead front are removable for installation and maintenance. Stay-open hinge
cover has safety interlock on dead front. Dead front must be removed before hinge cover can be removed.
NOTE: Cover may not close completely with twist-locking devices in use.
Tamper proof fastening available.

Utility requirements for this equipment may vary. Always consult the serving utility for their requirements before ordering or
installing equipment in this catalog.

I6

MILBANK

I7

U5100 & U5101 STANDARD CONFIGURATIONS

ORDERING INFORMATION
DESCRIPTION

U5100-XL-(*)

Ring type

(*) Add suffix from above chart to complete catalog number (ie: U5100-XL-11GR)

U5100-XL

Ring type

Order base model and up to three factory installed receptacle/breaker kit separately
from list below. Other kits available. Consult factory.

U5101-XL-(*)

Ringless

(*) Add suffix from above chart to complete catalog number (ie: U5101-XL-11GR)

U5101-XL

Ringless

Order base model and up to three factory installed receptacle/breaker kit separately
from list below. Other kits available. Consult factory.

CATALOG

NEMA

NUMBER

AMP

BLADE

VOLTAGE

CONFIG.

TYPE

CIRCUIT BREAKER TYPE

K5400-520

20

Straight

120

5-20

Std. Duplex

20 Amp 1 Pole

K5400-520GR

20

Straight

120

5-20

GFI Duplex

20 Amp 1 Pole

K5400-620

20

Straight

240

6-20

Single

20 Amp 2 Pole

K5400-620GB

20

Straight

240

6-20

Single

20 Amp 2 Pole GFI

K5400-1450

50

Straight

120/240

14-50

Single

30 Amp 2 Pole

K5400-1450GB

50

Straight

120/240

14-50

Single

30 Amp 2 Pole GFI

* Cover may not close completely while in use with Twist-Locking devices.

Utility requirements for this equipment may vary. Always consult the serving utility for their requirements before ordering or
installing equipment in this catalog.

I7

SECTION I

RECEPTACLE & CIRCUIT BREAKER KITS

TEMPORARY POWER

CATALOG # SOCKET TYPE

SECTION I

TEMPORARY POWER

I8

REPLACEMENT PARTS FOR MPAP / MPRV / HP PEDESTALS

CATALOG #

CIRCUIT BREAKER DESCRIPTION

Q115

15 Amp—1 Pole—120/240—Plug-In Circuit Breaker

Q120

20 Amp—1 Pole—120/240—Plug-In Circuit Breaker

Q130

30 Amp—1 Pole—120/240—Plug-In Circuit Breaker

Q220

20 Amp—2 Pole—120/240—Plug-In Circuit Breaker

Q250

50 Amp—2 Pole—120/240—Plug-In Circuit Breaker

Q2100

100 Amp—2 Pole—120/240—Plug-In Circuit Breaker

708784-MO

20 Amp—GFCI—1 Pole—120/240—Plug-In Circuit Breaker

708785-MO

30 Amp—GFCI—1 Pole—120/240—Plug-In Circuit Breaker

707915-MO

50 Amp—GFCI—2 Pole—120/240—Plug-In Circuit Breaker

703997-MO

50 Amp—Quad—2 Pole—120/240—Circuit Breaker

CATALOG #

RECEPTACLE DESCRIPTION

708777-MO

20 Amp—120V—NEMA 5-20R—Duplex Receptacle

708080-MO

20 Amp—120V—NEMA 5-20—GFCI Duplex Receptacle

704995-MO

20A—250V—NEMA 6-20R—Single Receptacle

701776-MO

30 Amp—120V—NEMA TT-30R—Travel Trailer Receptacle

706761-MO

50A—120V—3 Pole—3 Wire—NEMA 10-50R—Receptacle

Z700911-MO

50A—120/250V—3 Pole—4 Wire—NEMA 14-50R—Receptacle

CATALOG #

LUG LANDINGS & BREAKER BASE DESCRIPTION

Z020-509-01-00-0

MPRV / MPAP—Lug Landing (Twin #6-350 KCMIL)

Z020-148-00-00-0

MPAP—Complete Interior Assembly

*NOTE: The following brand names may be supplied when replacement circuit breakers are ordered: Cutler-Hammer/
Westinghouse—QP, BQC, BD, BR. Siemens/ITE—Q, QT. General Electric—TQ, THQ, THQL. Challenger—C, Q, QC,
QP. Contact sales office for brand specific requirements.

Utility requirements for this equipment may vary. Always consult the serving utility for their requirements before ordering or
installing equipment in this catalog.

I8

GALVANIZED STEEL DISTRIBUTION TRANSFORMER–1∅

J1

DRY TYPE TRANSFORMERS WITH DISTRIBUTION FOR RV & MOBILE HOME PARK APPLICATIONS

480 VOLTS TO 120/240 SINGLE PHASE

KVA

CAT. NO.

WT.

75
100
167 1⁄2
200
250

7URMD
10URMD
16URMD
20URMD
25URMD

850#
1050#
1400#
1650#
1950#

VOLTAGE
480V, A
2400V, A

A
48″
48″

DIMENSIONS
B
C
38″
40″
41″
53″

B

C

2400 VOLTS TO 120/240 SINGLE PHASE

CAT. NO.*

WT.

75
100
167 1⁄2
200
250

7URMD24
10URMD24
16URMD24
20URMD24
25URMD24

1050#
1200#
1650#
1900#
2200#

A

Specifications
• Built in accordance with NEMA, ASA and AIEEE standards. Designed and tested to withstand 150% of rated load for
two hours continuously. 480 Volt units are UL listed. Consult local utility for acceptance of this product.

• Primary and / or secondary main circuit breaker protection available. Consult local utility for 480 volt overcurrent
protection requirements. Single fuse primary overcurrent protection provided on 2400 volt and above units.
• Other primary voltages available: 4160, 4800, 7200, 7960, & 12,470. Consult factory. Not UL listed.

CORE AND COIL:

DISTRIBUTION BUS:

ENCLOSURE:

• Aluminum wound (Copper available)
• Standard voltage taps @ 2FCAN and 4FCBN
• Rated at 150° C temperature rise
• 1600 Amp tin plated aluminum
• Space available for up to (12) circuit breakers – 1600 amp maximum
• Uses Milbank type UQFP-100 through 200 amp circuit breakers (See page 18)
• Type 3R enclosure
• Powder coated galvanized steel (aluminum available)
• Lockable primary and secondary doors
• Lifting hooks and fork lift slots provided

* These models are not UL listed.

J1

SECTION J

• Integrated design of the enclosure, core and coil, and secondary distribution panel permits convenient vertical
line and load terminations.

TRANSFORMERS

KVA

SECTION J
NOTES

J2
NOTES

J2

ACCESSORIES

K1

INTERCHANGEABLE UNIT HUBS

HUB ADAPTER PLATE
(Converts 4″ opening to 21⁄2″)
S8324

SMALL “RL"
OPENING (STANDARD)
SUFFIX

SIZE

MILBANK
NO.

WL
YL
ZL
DL
EL

1″
11⁄4″

A7514
A7515
A7516
A7517
A7518

11⁄2″

2″
21⁄2″

LARGE “R”
OPENING (HEAVY DUTY)
SUFFIX

SIZE

MILBANK
NO.

F
G
H

3″
31⁄2″
4″

A8110
A8111
A8112

REMOVABLE HUB
CLOSING PLATE
DESCRIPTION SUFFIX

CAT. #

STANDARD
(for -RL opening)

-XL

A7551

LARGE
(for -R opening)

-X

A9064

CLOSING COVERS
HUB SUFFIX CHART
O
RL
R
XL
X

Plain Top
Small Hub Opening
Large Hub Opening
Small Closing Plate
Large Closing Plate
Large Hub Opening
RXL
adapted to small Closing Plate
METAL CLOSING PLATE
(For Ringless sockets)
CP-21

Large Hub Opening
RRL
adapted to small Hub Opening

G

31⁄2″

For -R Opening

H

4″

For -R Opening

ACCESSORIES & MISCELLANEOUS

METER CLOSING PLATE
(Ring type / Ringless)
6003 (Gray Plastic)
6116 (Clear Plastic)

WL 1″ For -RL Opening
YL 11⁄4″ For -RL Opening
ZL 11⁄2″ For -RL Opening
DL 2″ For -RL Opening
EL 21⁄2″ For -RL Opening
3″ For -R Opening
F

(For Ring type sockets)
MCP

CONNECTOR KITS
For use with 3/8”-16 stud
type units only
SINGLE
TWIN
CATALOG #

(3 per set) – 1 ∅

K1

K1539

K3

K1540

6-350
4-600 or
(2) 1/0-250
4-600 or
(2) 1/0-250
Non-rotating

K3L

K1540L

SUFFIX

CATALOG #

(4 per set) – 3 ∅

K5

K3082

6-350
4-600 or
(2) 1/0-250

K7

K3441

SUFFIX CATALOG #

K2

K1350

K2L

K1350L

K4

K1541

SUFFIX CATALOG #

K6
K8

K3442
K3083

(3 per set) – 1 ∅

6-350
6-350
Non-rotating
4-600
(4 per set) – 3 ∅

6-350
4-600

Utility requirements for this equipment may vary. Always consult the serving utility for their requirements before ordering or
installing equipment in this catalog.

K1

SECTION K

SUFFIX

K2

ACCESSORIES

SEALING RINGS

FIFTH TERMINALS
Consult factory for 5th terminal selection

100-200 amp
“PLUG-IN” FIFTH TERMINAL
5T8K2

HEAVY DUTY JAW
CLAMPING
K3865
(K3866 w/out neutral wire)

SNAP ACTION
MR-2

SCREW TYPE
(Stainless Steel)
MR-4

STAINLESS STEEL
MR2-SS

LOAD TAP CONNECTORS

SECTION K

ACCESSORIES & MISCELLANEOUS

200 amp
FIFTH TERMINAL
K5T
(New style block with square hole)

BYPASS LINK

DISCONNECT SLEEVE *
M5-144
(*NOT TO BE USED WITH LEVER
BYPASS SOCKETS)

K8180
(Bypass links sold in pairs)

Utility requirements for this equipment may vary. Always consult the serving utility for their requirements before ordering or
installing equipment in this catalog.

K2

UQFP PLUG-IN SERIES CIRCUIT BREAKERS

K3

UQFP

200 AMP FRAME—PLUG-IN—10,000 AIC & 22,000 AIC
TWO-POLE—COMMON TRIP
10K AIC
PLUG-IN

22K AIC
PLUG-IN

100

UQFP-100

UQFPH-100

125

UQFP-125

150

AMPS

10K AIC
PLUG-IN

22K AIC
PLUG-IN

WIRE RANGE
AL

UQFP-M-100 UQFPH-M-100

#3-#1

#1-1/0

UQFPH-125

UQFP-M-125 UQFPH-M-125

#3-#1

#1-1/0

UQFP-150

UQFPH-150

UQFP-M-150 UQFPH-M-150

1/0-300

2/0-300

175

UQFP-175

UQFPH-175

UQFP-M-175 UQFPH-M-175

1/0-300

2/0-300

200

UQFP-200

UQFPH-200

UQFP-M-200 UQFPH-M-200

1/0-300

2/0-300

UL LISTED: For use with 60°C or 75°C wire.
UQFP: For parallel main circuit breaker applications
UQFP-M: For series main circuit breaker applications. Split load tab features allow for feed
through capability.
STANDARD PACKAGING: 5 units per 16 lb. carton.

Utility requirements for this equipment may vary. Always consult the serving utility for their requirements before ordering or
installing equipment in this catalog.

K3

SECTION K

CU

ACCESSORIES & MISCELLANEOUS

UQFP-M

K4

UQFB BOLT-ON SERIES CIRCUIT BREAKERS

UQFB-X

SECTION K

ACCESSORIES & MISCELLANEOUS

UQFB-X1

UQFB

UQFB-X-MOD

200 AMP FRAME—BOLT-ON—10K AIC & 22K AIC
TWO-POLE—COMMON TRIP
10K AIC
BOLT-ON

22K AIC
BOLT-ON

100

UQFB-100

125

AMPS

10K AIC
BOLT-ON

WIRE RANGE
CU

AL

UQFBH-100 UQFB-100-X1

#3-#1

#1-1/0

UQFB-125

UQFBH-125 UQFB-125-X1

#3-#1

#1-1/0

150

UQFB-150

UQFBH-150 UQFB-150-X1

1/0-300

2/0-300

175

UQFB-175

UQFBH-175 UQFB-175-X1

1/0-300

2/0-300

200

UQFB-200

UQFBH-200 UQFB-200-X1

1/0-300

2/0-300

UL LISTED: For use with 60°C or 75°C wire.
UQFB: (2) 1/0-300 kcmil lugs provided on load and line side (cable-in, cable-out.)
UQFB3: Three pole available. Consult factory.
UQFB-X: (2) 1/0-300 kcmil lugs provided on load side and (2) line bar bus connections on line side.
UQFB-M: For series main circuit breaker applications. Split load tab features allow for feed through capability.
UQFB-X-MOD: Replacement circuit breaker with line barriers removed.
STANDARD PACKAGING: 5 units per 16 lb. carton.

Utility requirements for this equipment may vary. Always consult the serving utility for their requirements before ordering or
installing equipment in this catalog.

K4

CONDUIT, AMPACITY & SCCR INFORMATION

MAXIMUM NUMBER OF CONDUCTORS IN CONDUIT*
CONDUCTOR
SIZE
AWG,MCM

TYPE

RHW & RHH
(without outer covering)
THW

TW
THW
FEPB (6 thru 2),
RHW and
RHH
(without outer covering)
RH, THHW

*CU

CONDUIT TRADE SIZES (INCHES)
1

⁄2

3

⁄4

1

11⁄4 11⁄2

2

21⁄2

14
12
10
8

6
4
4
1

10
8
6
3

16
13
11
5

29
24
19
10

40
32
26
13

65
53
43
22

93
76
61
32

143 192
117 157
95 127 163
49 66 85

6

1

2

3

7

10

16

23

36

48

62

3

1

1

2

4

6

10

15

23

31

40

1
1
1

1
1
1
1

2
1
1
1

3
3
2
1

5
5
4
3

8
7
6
5

12
10
9
7

16
14
12
10

21
18
15
13

1
1

1
1
1
1
1

1
1
1
1
1

2
2
1
1
1

4
3
3
2
1

6
5
4
4
3

8
7
6
5
4

10
9
8
7
6

1
1
1

1
1
1

1
1
1

3
2
2

4
3
3

5
4
4

1/0
2/0
3/0
4/0

250
300
350
400
500
600
700
750

3

31⁄2

4

*This table is for concentric stranded conductors only. For cables with compact conductors
refer to N.E.C.

AL

or

Cu-Clad AL

A

B

A

C

18
16
14
12
10
8

—
—
20
25
35
50

—
—
—
12
10
8

—
—
—
20
30
40

6
4
3
2
1

65
85
100
115
130

6
4
3
2
1

50
65
75
90
100

1/0
2/0
3/0
4/0

150
175
200
230

1/0
2/0
3/0
4/0

120
135
155
180

250
300
350
400
500

255
285
310
335
380

250
300
350
400
500

205
230
250
270
310

600
700
750

420
460
475

600
700
750

340
375
385

* Allowable ampacities of insulated

A = Size: AWG/MCM
B = Ampere Rating for Insulation
Types: FEPW, RH, RHW, THW,
THWN, XHHW, USE, 2W.
C = Ampere Rating for Insulation
Types: RH, RHW, THW, THWN,
XHHW, USE
(Per NEC table 310-16)

100A / POS.
AMPACITY
200A
200A
200A
225A
270A

125A / POS.
AMPACITY
200A
225A
250A
285A
330A

150A / POS.
AMPACITY
200A
225A
270A
338A
396A

200A / POS.
AMPACITY
200A
270A
360A
450A
528A

All meter sockets are 600 volt rated unless otherwise noted.
All meter socket ampacity ratings are continuous duty unless otherwise noted.

K5

AMBIENT
TEMP.C°
21 - 25
26 - 30
31 - 35
36 - 40
41 - 45
46 - 50
51 - 55
56 - 60
61 - 65
66 - 70

CORRECTION
FACTOR
1.05
1.00
.94
.88
.82
.75
.67
.58
.33
—

AMBIENT
TEMP.F°
70 - 77
79 - 86
88 - 95
97 - 104
106 - 113
115 - 122
124 - 131
133 - 140
142 - 158
160 - 176

SECTION K

GANG SOCKET OVERALL AMPACITIES
NO. OF METER
POSITIONS
2
3
4
5
6

AMPACITY CORRECTION FACTORS

ACCESSORIES & MISCELLANEOUS

Copper & Aluminum conductors
(3W in conduit) 75°C (167°F)

 Unless otherwise permitted elsewhere in
the Code, the overcurrent protection for
conductor types marked with an obelisk
(
) shall not exceed 15 amps for 14
AWG, 20 amps for 12 AWG, and 30
amps for 10 AWG copper: or 15 amps
for 12 AWG and 25 amps for 10 AWG
aluminum and copper-clad aluminum
after any correction factors for ambient
temperature and number of conductors
have been applied.

Overall ampere ratings of UL Listed Milbank multiple position meter sockets are
based on 1993 N.E.C. Manual article 220-32 and ANSI / UL-414 (except where
restricted by line connector size.) These requirements provide for a diversity factor /
demand factor being utilized in determining the overall (main bus / lug) rating of a gang
socket. All Milbank UL Listed gang sockets meet or exceed these diversity
factor/demand factor requirements. Standard overall ampacity ratings for UL Listed
and non UL Listed gang sockets are as shown in the chart below. Ampere ratings of
meter sockets are based on the meter socket being wired with 75° C insulated wire
conductor, sized in accordance with Table 310-16 of the National Electric Code.

K5

K6

ENERGIZATION OF ELECTRICAL EQUIPMENT

IMPORTANT NOTE
In addition to national and local electrical codes, many utilities have specific requirements for metering
equipment. Always consult the serving utility for their specifications and requirements prior to ordering or
installing Milbank meter mounting equipment.

BEFORE ENERGIZING
A. Give equipment a thorough visual examination to determine that:
1) No shipping or installation damage exists.
2) Proper clearances have been maintained.
3) All connections have been made.
4) Equipment is clean and dry.
B. Make a thorough examination to:
1) Verify tightness of all bolted connections (see table below).
2) Manually operate all circuit breakers, switches, relays, etc.
3) Check rigidity of all mountings, bus bars and components.
4) Use test equipment to check continuity of circuitry and integrity of insulation.
C. All switches and circuit breakers should be in the “off” position.
D. Verify that manual meter bypass (if applicable) is in non-bypass position.
E. Install cover and/or close doors.
F. If installation is not being energized at this time, follow “after-energizing” steps listed below. These
steps will secure the installation in case of accidental energization.

WHEN ENERGIZING

SECTION K

ACCESSORIES & MISCELLANEOUS

A. Use caution and follow established safety procedures:
1) Wear safety apparel.
2) Use safety equipment.
3) Take action to prevent injury to yourself and others in the event of failure of the installation.
4) Take action to prevent/decrease damage to property in the event of failure of the installation.
5) If you are unsure how to safely energize the installation, get someone who is knowledgeable to do it.

AFTER ENERGIZING
A. Secure the installation:
1) To prevent accidental contact with energized parts, cover all openings with approved filler devices.
2) To prevent unauthorized access, secure all covers and/or doors with approved security devices.
3) Attach/post information to advise others of potential hazards associated with the installation.

RECOMMENDED TORQUE FOR GENERAL APPLICATIONS*
JOINT DESCRIPTION

NOMINAL
SIZE

SCREW

NUT

10
10
10
12
12
1/4
1/4
5/16
5/16
3/8
1/2

BRASS
STEEL
STEEL
STEEL
STEEL
STEEL
STEEL
STEEL
STEEL
STEEL
STEEL

Brass Nut or Extruded Hole
CU or AL Busbar <1/8″
Steel Nut or EH; CU or AL Busbar >1/8″

Aluminum Extruded Hole
Steel Nut or Extruded Hole
Aluminum Extruded Hole
Steel Nut or EH; CU or AL Busbar
Aluminum Extruded Hole
Steel Nut or EH; CU or AL Busbar
Steel Nut
Steel Nut

HEAD TYPE

TORQUE
( INCH LBS. )

ALL
ALL
ALL
ALL
ALL
ALL
ALL
HEX
HEX
HEX
HEX

20-25 in. lbs.
25-30 in. lbs
30-35 in. lbs
30-35 in. lbs
40-50 in. lbs.
40-50 in. lbs.
50-60 in. lbs.
60-70 in. lbs.
100-150 in. lbs.
150-200 in. lbs.
200-250 in. lbs.

*Interior labels typically indicate the required torque for wire connectors and studs, and should be referenced first.
EH: Extruded Hole
CU: Copper
AL: Aluminum

K6

MATERIALS AND FINISHES

K7

MATERIALS
STEEL QUALITY
The meter equipment listed in this catalog is made of galvanized steel (AISI* G90) to afford the
best possible weather proofing. *American Iron and Steel Institute.

STEEL SHEET
16 gauge, galvanized, sheet: 1 1/4 oz./ sq.ft. class zinc-coated.
(AISI G90)
14 gauge, galvanized, sheet: 1 1/4 oz./ sq.ft. class zinc-coated.

ALUMINUM EXTRUSION
Wire-Terminals: Alloy; 6061-T6, Tin-plated for CU/AL wire.
Bus Bar: Alloy; 6101-o & 6063-O

ALUMINUM SHEET
3000 series aluminum sheet, H14, or 5052 series aluminum sheet, H32. Where applicable
thicknesses range from .064 — .125

COPPER SHEET & BUS
Electrolytic copper with tin plating in most applications.

INSULATING MATERIALS
• In most units, support bases for current-carrying components are molded from fiberglass
reinforced high-strength, track resistant, thermoset polyester molding compounds.

• Various sheet insulating materials, as appropriate for the application are utilized in the
fabrication of flat, formed and punched component parts and barriers.

FINISH
PROCESS
Light gray “state of the art” electrostatically applied powder paint offers a durable, non-fading
finish. For further information concerning the chemical analysis of the weather resistant finish,
please contact the factory.

SECTION K

METAL FASTENERS

ACCESSORIES & MISCELLANEOUS

• Clear or black safety shields and polarity barriers are molded from high-strength, track resistant,
polycarbonate molding compounds.

Zinc-coated with a chromate dip.

RATING
NEMA RATING
Milbank meter sockets, CT cans and meter socket / breaker units have a type 3R rating.

K7

K8

METER FORMS

DIAGRAM A

DIAGRAM B

DIAGRAM C

DIAGRAM D

1∅2W with 1 P.T. & 1 C.T.
Single Stator Meter(2W1∅) - Form 3S
5T Socket, Test Switch #TS04-0101

1∅3W with 1 C.T.
Single Stator Meter(2W1∅) - Form 3S
5T Socket, Test Switch #TS04-0101

1∅3W with 2 C.T.ʼs
Single Stator Meter(3W1∅) - Form 4S
6T Socket, Test Switch #TS07-0105

1∅3W or 3W Network with 2 C.T.ʼs
2 Stator Meter - Form 5S
8T Socket, Test Switch #TS07-0105

DIAGRAM A

DIAGRAM B

DIAGRAM D

(ALT.LOC.)

(ALT.LOC.)

P1 PN

DIAGRAM C

+
C1

+
C1

P1 PN

C1

C1

+
C1

P1 P2

+
C2

+
C2 C2

+
C1

P1 P2 PN

+
C2 C2

C1

+

P.T. +

+
+

I
LINE
N

I

+

LINE 2
N

C.T.

(BONDED)

ACCESSORIES & MISCELLANEOUS

LOAD
LINE

(BONDED)

+

I
N(BONDED)
2

C.T.
C.T. +

LOAD

+

LINE

+

I
N(BONDED)
2

C.T.

+

LOAD

+

C.T.

DIAGRAM E

DIAGRAM F

DIAGRAM G

DIAGRAM H

3∅3W “Δ” with 2 P.T.ʼs & 2 C.T.ʼs
2 Stator Meter - Form 5S
8T Socket, Test Switch #TS07-0105

3∅3W “Δ” with 2 C.T.ʼs
2 Stator Meter - Form 5S
8T Socket, Test Switch #TS07-0105

3∅4W “Y” with 3 C.T.ʼs
2 1⁄2 Stator Meter - Form 6S
13T Socket, Test Switch #TS10-0109

3∅4W “Y” with 2 P.T.ʼs & 3 C.T.ʼs
2 1⁄2 Stator Meter - Form 6S
13T Socket, Test Switch #TS10-0109

DIAGRAM E

SECTION K

+

+

+

LOAD

C.T.

DIAGRAM G

DIAGRAM F

P1
P1 P3

P2 C+1

+
C3 C3

C1

P2 C+1

P1 P3

P3 PN C+

DIAGRAM H

C+ C

C

C+ C

P1

P3 PN

+
PT

PT

PT

+

+

+

+

1
LINE 2
3

1
2
LINE
3
N

+

+
C.T.

+

LOAD

+
C.T.

+

1
LINE 2
3

C.T.

+

LOAD

+
C.T.

DIAGRAM I

DIAGRAM J

3∅4W “Y” or “Δ” with 3 C.T.ʼs
“Y” 3 Stator Meter - Form 9S
“Δ” 2 Stator Meter - Form 8S
13T Socket, Test Switch #TS10-0109

3∅4W “Y” with 3 P.T.ʼs & 3 C.T.ʼs
3 Stator Meter - Form 9S
13T Socket, Test Switch #TS10-0109

DIAGRAM I

P1 P2 P3 PN

+
C

+
C

C

C

+
C C

P1 P2 P3 PN

C

C+

+
C.T.

+

C.T.

LOAD

+
+

C.T.

1
2
LINE
3
N(BONDED)

C+

+
+

C

+

+

+
C.T.

+

(BONDED)

+
PT

C.T.

LOAD

+
+

C.T.

1
2
LINE
3
N(BONDED)

+

+
+

+
C.T.

+

C.T.

LOAD

+
+

C+

C

C

PREWIRING: If standard factory prewiring is
required, refer to wiring diagrams on this page.
Determine appropriate diagram and send a
copy with order. If custom factory prewiring is
required, specify on order. Be sure to include
meter socket catalog number, test switch make
and catalog number, meter form number and
provide a copy of your wiring diagram.

C+ C

PT

PT PT

+ +
+ +

+

C+

C

DIAGRAM J

+

1
2
LINE
3
N(BONDED)

C+

+
C3 C3

C1

+
+

+
C.T.

+

C.T.

+

LOAD

+

C.T.

K8

C.T.

WATTHOUR METER FORMS—STANDARD FORMS
TRANSFORMER RATED OR SELF-CONTAINED

SC
2 and 3-WIRE FORMS
1S & 2S

SC
2 and 3-WIRE FORMS
1S & 2S with BYPASS

TR

TR

2-WIRE FORM 3S
5th Term. 9 o'clock

2-WIRE FORM 3S
with BYPASS

TR
2-WIRE FORM 3S
5th Term.6 o'clock

TR

SC

SC

SC

2-WIRE FORM 3S
with BYPASS

2 ELEMENT
3-WIRE NETWORK
FORM 12S 5th
TERM. 9 o'clock

2 ELEMENT 3-WIRE
NETWORK FORM 12S
with BYPASS
5th Term. 9 o'clock

2 ELEMENT
3-WIRE NETWORK
FORM 12S 5th
TERM. 6 o'clock

TR

TR

SC

3-WIRE FORM 4S

3-WIRE FORM 4S
WITH BYPASS

TR

TR

SC

SC

TR

2 ELEMENT
2∅3W, 2∅4W, 3∅3W
FORM 5S

2 ELEMENT 2∅3W,
2∅4W, 3∅3W
FORM 5S with
BYPASS

2 ELEMENT
2∅3W, 2∅4W, 3∅3W
FORM 13S

2 or 3 ELEMENT
2∅3W, 2∅4W, 3∅3W
FORM 13S with
BYPASS

2 or 3 ELEMENT
3∅4W Y or ∆
Y FORM 9S
∆ FORM 8S

TR

TR

TR

2 ELEMENT
3∅4W Y
FORM 6S

2 ELEMENT
3∅4W Y
FORM 6S
with BYPASS

2 or 3 ELEMENT
3∅4W Y or ∆
FORMS 14S & 15S
with BYPASS

SC
2 ELEMENT 3-WIRE
NETWORK FORM 12S
with BYPASS
5th Term. 6 o'clock

TR
2 ELEMENT
3∅4W Y or ∆
Y FORM 7S
∆ FORM 24S
with BYPASS

ACCESSORIES & MISCELLANEOUS

2 or 3 ELEMENT
3∅4W Y or ∆
Y FORM 14S
∆ FORM 15S

SC

K9

SECTION K

TR = TRANSFORMER RATED
SC = SELF CONTAINED

2 or 3 ELEMENT
3∅4W Y or ∆
FORMS 8S & 9S
with BYPASS

Utility requirements for this equipment may vary. Always consult the serving utility for their requirements before ordering or
installing equipment in this catalog.

K9

K10

STANDARD NEMA CONFIGURATIONS

2 POLE—3 WIRE—GROUNDING RECEPTACLES
STRAIGHT BLADE WIRING DEVICES
VOLTS CODE

15
AMPS

20
AMPS

G

125V 5

30
AMPS

TWIST-LOCK WIRING DEVICES
50
AMPS
G

G

G

W

30
AMPS
W

W
G

G

L5-20R

L5-30R

G

W

5-15R

5-20R

G

5-30R

5-50R

G

G

L5-15R

G

G

G

G

6-20R

G

G

W

W

6-30R

6-50R

G

L6-15R

G

7-15R

W

7-20R

7-30R

L6-20R

L6-30R
W

W

W

G

G

G

7

Y

Y

Y

6-15R

X

X

X

250V 6
277
VAC

20
AMPS

W

W

W

15
AMPS

W

7-50R

L7-15R

L7-20R

L7-30R

3 POLE—3 WIRE—SPECIAL APPLICATIONS
STRAIGHT BLADE WIRING DEVICES

SECTION K

ACCESSORIES & MISCELLANEOUS

VOLTS CODE

125V 10
250V

20
AMPS

30
AMPS

50
AMPS

W

W

TWIST-LOCK
20
AMPS

30
AMPS
X

X

W

Y

W

W
X

Y

X

10-20R

10-30R

X

Y

10-50R

Y

L10-20R

Y

L10-30R

3 POLE—4 WIRE—GROUNDING
STRAIGHT BLADE WIRING DEVICES
VOLTS CODE

125V 14
250V

15
AMPS

20
AMPS

G
Y

30
AMPS

Y

50
AMPS

G

G
X

TWIST-LOCK

X
W

W

Y

X

Y

14-20R

30
AMPS
X

X

G
X

G

W

G

W

W
W

14-15R

20
AMPS

14-30R

14-50R

Y

L14-20R

Y

L14-30R

2 POLE—3 WIRE—GROUNDING—NEMA TRAILER

STRAIGHT BLADE
VOLTS CODE

30
AMPS
G

125V TT

W

TT-30R

Utility requirements for this equipment may vary. Always consult the serving utility for their requirements before ordering or
installing equipment in this catalog.

K10

ADDITIONAL MILBANK PRODUCTS

K11

Other quality products available from Milbank
COMMERCIAL ENCLOSURES

2007 PRICE LIST

Effective June 26, 2006
Supercedes and cancels all previous Milbank lists.
All prices listed within are subject to change without notice.

MILBANK MFG. CO.– ENCLOSURE GROUP
1601 South St. Louis Street
Concordia, MO 64020
Tel: 660-463-0805 Fax: 660-463-7950
Toll Free: 1-877-483-5314
www.milbankmfg.com

Contact your local distributor or go to
www.milbankmfg.com
to find additional product literature.

K11

SECTION K

Air Conditioner Disconnects
Hot Tub Disconnects
RV/Mobile Home Power Outlets
Terminal Boxes
Temporary Power Outlets
Commercial Pedestals
Commercial Enclosures
CT Enclosures
Circuit Breakers
Enclosed Circuit Breakers
Safety Switches
Test Switches

ACCESSORIES & MISCELLANEOUS

In addition to your local utility’s meter mounting
equipment, Milbank also manufactures
supporting products, such as...

SECTION L

ALPHA-NUMERIC INDEX

L1

ALPHA-NUMERIC INDEX

6003 .................................K1

708785-MO........................I8

CT303611-HC ..................F2

K5400-520GR....................I2

MPRV-100-78 ..................G1

6116 .................................K1

A3800 ...............................A1

CT303614-SC...................F2

K5400-620 .......................G9

MPRV-100-MB-78............G1

020-147-00-00-0 ............G10

A7514 ...............................K1

CT304811-HC ..................F2

K5400-620 .........................I2

MPRV-100-MBLC-80 .......G3

020-148-00-00-0 ............G10

A7515 ...............................K1

CT363611-SC...................F2

K5400-620GB ....................I2

MPRV-200-MBLC-80 .......G3

020-509-01-00-0 ............G10

A7516 ...............................K1

CT364211-SC...................F2

K5400-620GR ..................G9

MPRV-503020GR-78.......G1

105J..................................E2

A7517 ...............................K1

CT364811-HC ..................F2

K5400-BLANK................H17

MPRV-50-78 ....................G1

114TB...............................D1

A7518 ...............................K1

CT364811-SC...................F2

K5400-BRIDGE..............H17

MPRV-BLANK-78 ............G1

115TB...............................D1

A7551 ...............................K1

CT364814-HC ..................F2

K5400-BRIDGE-1POS..G5-9

MPRV-BLANK-78-R-5T ...G1

116TB...............................D1

A8110 ...............................K1

CT364814-SC...................F2

K5400-BRIDGE-2POS..G5-9

MR-2 ..............................H18

124TB...............................D1

A8111 ...............................K1

CT424211-SC...................F2

K5400-GB ......................H17

MR-2.................................K2

125TB...............................D1

A8112 ...............................K1

CT484811-HC ..................F2

K5400-NEUTRAL...........H17

MR-2SS............................K2

127TB...............................D1

A9064 ...............................K1

CT484811-SC...................F2

K5400-TT30 ......G5-9, H2-10

MR-4.................................K2

214MTB............................D2

AP-2300-03 ......................B1

CT484814-HC ..................F2

K5400-TT30 ...................H17

MS24-TB ........................D16

214MTB/22.......................D3

AP-2300-04 ......................B1

ED42B100......................D14

K5400-TT30GB...........H2-10

MS27-TB ........................D16

214MTB-48 ......................D4

BC214 ............................D12

ED43B100......................D14

K5410.............................H15

P-10GR ..........................H16

214MTB-P ........................D5

BC234 ............................D12

FXD62B200....................D14

K5411.............................H13

P-13................................H16

214MTB-P48 ....................D5

BC318 ............................D12

FXD63B200....................D14

K5412.............................H13

P-54................................H16

215MTB............................D2

BC338 ............................D12

K1350 .............................B15

K5413.............................H13

PB-011 ...........................D11

215MTB-48 ......................D4

BC418 ............................D12

K1350 ...............................K1

K5415 ...........................G5-7

PB-012 ...........................D11

215MTB-P ........................D5

BC438 ............................D12

K1350L .............................K1

K5415.............................H15

PB-014 ...........................D11

215MTB-P48 ....................D5

BC518 ............................D12

K1539 .............................B15

K5421.............................H15

PB-014-NK .....................D11

217MTB............................D2

BC538 ............................D12

K1539 ...............................K1

K5421.............................H15

PB-018 ...........................D11

217MTB/22.......................D3

BC618 ............................D12

K1540 .............................B15

K5747 ...............................F3

PB-018-NK .....................D11

217MTB-48 ......................D4

BC638 ............................D12

K1540 ...............................K1

K5757 ...............................F3

PB-032 ...........................D11

217MTB-P ........................D5

CL200.............................H16

K1540L .............................K1

K5T ...............................G5-7

PB-034 ...........................D11

217MTB-P48 ....................D5

CP-16PDMNT-CALT ........E2

K1541 .............................B15

K5T...................................K2

PB-034-NK .....................D11

224MTB............................D6

CP-21 ...............................K1

K1541 ...............................K1

K8180 ...............................K2

PB-038 ...........................D11

224MTB/22.......................D7

CP-24PDMNT-CALT ........E2

K3082 ...............................K1

KK3388.............................F7

PF-BL.............................G11

224MTB-P ........................D9

CP3B11110A22SL1 .........E5

K3083 ...............................K1

KK3388-BLK-FL ...............F7

PF-KR ............................G11

224MTB-P48 ....................D9

CP3B11115A22................E4

K3441 ...............................K1

M400-APS........................C5

PT223.............................D16

225MTB............................D6

CP3B11115A42................E4

K3442 ...............................K1

M400-APS-BS..................C5

PT224.............................D16

225MTB-P ........................D9

CP3B111IRASP ...............E7

K3450 ...........................G5-7

M400-PAR........................C4

PT263.............................D16

225MTB-P48 ....................D9

CP3B111IRASS ...............E7

K3865 ...............................E2

M400-PAR-UG .................C4

PT264.............................D16

227MTB............................D6

CP3B12110A22SL1 .........E5

K3865 ...............................K2

M400-UG-APS-F..............C6

PT323.............................D16

227MTB/22.......................D7

CP3B12119A22................E4

K3866 ...............................K2

M400-UG-APS-F-BS........C6

PT324.............................D16

227MTB-125 ..................D14

CP3B1411JB22................E6

K4709-02........................H14

M400-UG-APS-LC ...........C6

PT363.............................D16

227MTB-150 ..................D14

CP3B14120B22................E6

K4709-WS......................H14

M400-UG-APS-LC-BS .....C6

PT364.............................D16

227MTB-175 ..................D14

CP3B51110A22SL1 .........E5

K4722 ...............................F3

M400-UG-APS-P..............C6

Q115 ..................................I8

227MTB-48 ......................D8

CP3B51115A22................E4

K4729 ...............................F3

M401-UG..........................C7

Q120 ..............................H18

227MTB-P ........................D9

CP3B511IRASP ...............E7

K4793 ...............................F3

M401-UG-BS....................C7

Q120 ..................................I8

227MTB-P48 ....................D9

CP3B52110A22SL ...........E5

K4794 ...............................F3

M404-UG-LC....................C8

Q130 ..............................H18

243210-LC3R-SP .............F1

CP3B52119A22................E4

K4795 ...............................F3

M404-UG-LC-BS..............C8

Q130 ..................................I8

323610-LC3R-SP .............F1

CP3B5411JB22................E6

K4796 ...............................F3

M5-144 .............................K2

Q220 ..................................I8

363016-CT3R ...................F1

CP3B8411JB22................E6

K4797 ...............................F3

MCP .................................K1

Q250 ..............................H18

363612-CT3R-SP .............F1

CP3B84120B22................E6

K4798 ...............................F3

MN1020-TVB ....................J1

Q250 ..................................I8

364812-CT3R-SP2 ...........F1

CP3B-AUX-1200 ............H11

K4800-01........................H16

MN1100 ............................J1

QJ22B200H....................D14

403456-SC.....................G11

CP-ABK5/8 .......................E2

K4903 ...............................F3

MN1100-NG......................J1

QJ23B200 ......................D14

403457-SC.....................G11

CP-PE-HOA-3POS...........E2

K4904 ...............................F3

MN-1100-TV .....................J1

QJH23B200L..................D14

5T8K2...............................K2

CP-TC24H........................E2

K5035 ...........................G5-7

MN2200 ............................J1

RBK-1 ............................G10

701776-MO ....................H17

CP-TC7D..........................E2

K5039 ...........................G5-7

MN900 ..............................J1

S8324 ...............................K1

701776-MO........................I8

CP-TCWIRE .....................E2

K5193 ...........................G5-7

MN900-B...........................J1

TB100-47 .......................D16

703997-MO........................I8

CT203611-HC ..................F2

K5194 ...........................G5-7

MPAP-100-78 ..................G2

TB100-5 .........................D16

704995-MO........................I8

CT242411-SC...................F2

K5400-1450 ......G5-9, H2-10

MPAP-100-MB-78............G2

TB200-47 .......................D16

706761-MO........................I8

CT243011-HC ..................F2

K5400-1450....................H17

MPAP-200-20GR-78........G2

TB200-LL .......................D16

707915-MO........................I8

CT243011-SC...................F2

K5400-1450 .......................I2

MPAP-200-78 ..................G2

TB-BARR .......................D16

708080-MO ....................H17

CT24329-SC.....................F2

K5400-1450GB ................G9

MPAP-200-MB-78............G2

TS04-0049........................F8

708080-MO........................I8

CT243611-HC ..................F2

K5400-1450GB ..................I2

MPAP-BLANK-78.............G2

TS04-0101........................F8

708676-MO ....................H17

CT243611-SC...................F2

K5400-520 ......................I2-7

MPAP-BLANK-78-R.........G2

TS04-0104........................F8

708777-MO........................I8

CT244811-HC ..................F2

K5400-520GB .............H2-10

MPAPD-BLANK-78 ..........G2

TS04-0105........................F8

708784-MO ....................H18

CT244811-SC...................F2

K5400-520GR ...G5-9, H2-10

MPAPD-BLANK-78R .......G2

TS04-0106........................F8

708784-MO........................I8

CT303011-SC...................F2

K5400-520GR ................H17

MPRV-100-20GR-78........G1

TS10-0016........................F8

L1

ALPHA-NUMERIC INDEX

U4909-O ............................I2

U5268-XTL-150................C2

UQFB-100-X1...................K4

U2855-X .........................B15

U4909-O-11GR..................I2

U5268-XTL-150-KK..........C2

UQFB-125 ........................K4

TS10-0111........................F8

U2856-X .........................B15

U4909-O-55GBGR ............I2

U5268-XTL-200................C2

UQFB-125-X1...................K4

TS10-0112........................F8

U2862-X .........................B15

U4969-KO ........................B5

U5268-XTL-200-KK..........C2

UQFB-150 ........................K4

U1060-RL .........................B3

U2863-X .........................B15

U5000-XL .........................H2

U5269-XTL-200................C2

UQFB-150-X1...................K4

U1079-R .........................B10

U2864-X .........................B15

U5000-XL...........................I4

U5300-O.........................H10

UQFB-175 ........................K4

U1129-O-K3L-K2L..........B10

U2865-X .........................B15

U5000-XL-332..................H2

U5300-O-41 ...................H10

UQFB-175-X1...................K4

U1211-RXL.......................B7

U2866-X .........................B15

U5000-XL-41....................H2

U5300-O-55 ...................H10

UQFB-200 ........................K4

U1252-X-K1....................B13

U3251-O-200-CB .............C6

U5000-XL-55....................H2

U5300-O-552GR ............H10

UQFB-200-X1...................K4

U1253-X-K3....................B13

U3320-R ...........................F4

U5000-XL-75....................H2

U5300-O-75 ...................H10

UQFBH-100......................K4

U1254-X-K3....................B13

U3322-R ...........................F4

U5000-XL-75GB...............H2

U5310-O.........................H10

UQFBH-125......................K4

U1255-X-K4....................B13

U3328-RXL.......................B4

U5001-RL-01 .....................I5

U5320-O.........................H10

UQFBH-150......................K4

U1256-X-K4....................B13

U3340-O ...........................F4

U5056-O.........................B10

U5330-O.........................H10

UQFBH-175......................K4

U1431-R .........................B10

U3342-O ...........................F4

U5059-X-2/200.................C4

U5706-O-200S.................G9

UQFBH-200......................K4

U1432-O.........................B10

U3462-O.........................D13

U5100-XL .........................H4

U5706-O-200S-KK...........G9

UQFP-100 ......................H11

U1527-O...........................B3

U3463-O.........................D13

U5100-XL...........................I7

U5707-O-200S.................G9

UQFP-100 ........................K3

U1681-RL .........................B2

U3464-O.........................D13

U5100-XL-41....................H4

U5759-X-2/200.................C4

UQFP-125 ......................H11

U1797-O-K3L-K2L..........B10

U3465-O.........................D13

U5100-XL-55....................H4

U7021-RL-TG..................`B3

UQFP-125 ........................K3

U1819-X .........................B10

U3466-O.........................D13

U5100-XL-552GR ............H4

U7040-XL-TG ...................B3

UQFP-150 ......................H11

U1980-O...........................B3

U3504-XL .........................B9

U5100-XL-75....................H4

U7043-XL-TG ...................B3

UQFP-150 ........................K3

U2120-X .........................B11

U3507-XL .........................B9

U5100-XL-75GB...............H4

U7422-RXL.......................B6

UQFP-175 ......................H11

U214MTB .........................D2

U3514-XL .........................B9

U5101-XL .........................H4

U7423-RXL.......................B6

UQFP-175 ........................K3

U214MTB/22 ....................D3

U3517-XL .........................B9

U5101-XL...........................I7

U7487-O...........................B2

UQFP-200 ......................H11

U214MTB-48....................D4

U3522-XL-K1..................B12

U5136-O ..........................G7

U7487-RL .........................B2

UQFP-200 ........................K3

U214MTBL .....................D10

U3523-XL-K1..................B12

U5136-O-100S.................G7

U7490-O...........................B2

UQFP-225 ......................H11

U214MTB-P .....................D5

U3524-XL-K2..................B12

U5136-O-200S.................G7

U7490-RL .........................B2

UQFPG-100 .....................K3

U214MTB-P48 .................D5

U3525-XL-K2..................B12

U5137-O ..........................G7

U7573-RL .........................B6

UQFPG-125 .....................K3

U214MTBPL...................D10

U3532-X-K1....................B13

U5137-O-100S.................G7

U8032-XL .......................B12

UQFPG-150 .....................K3

U215MTB .........................D2

U3533-X-K3....................B13

U5137-O-200S.................G7

U8033-XL .......................B12

UQFPG-175 .....................K3

U215MTB-48....................D4

U3548-X .........................B11

U5138-O ..........................G7

U8034-XL .......................B12

UQFPG-200 .....................K3

U215MTB-P .....................D5

U3555-R ...........................F4

U5138-O-200S.................G7

U8035-XL .......................B12

UQFPH-100 ...................H11

U215MTB-P48 .................D5

U3565-O ...........................F4

U5168-100-KK-5T ............C2

U8036-XL .......................B12

UQFPH-125 ...................H11

U217MTB .........................D2

U3574-RL-200..................C1

U5168-150-KK-5T ............C2

U8100-RL .........................B6

UQFPH-150 ...................H11

U217MTB/22 ....................D3

U3577-RL-200..................C1

U5168-XTL-100................C2

U9319-XL .........................B7

UQFPH-175 ...................H11

U217MTB-48....................D4

U3587-O-200 ...................C1

U5168-XTL-100-KK..........C2

U9320-RXL.......................B6

UQFPH-200 ...................H11

U217MTBL .....................D10

U3800...............................A1

U5168-XTL-150................C2

U9550-RRL ......................B8

UQFPH-225 ...................H11

U217MTB-P .....................D5

U3801...............................A1

U5168-XTL-150-KK..........C2

U9551-RXL.......................B8

UQFPH-M-100 .................K3

U217MTB-P48 .................D5

U3830...............................A1

U5168-XTL-200................C2

U9700-RRL ......................B8

UQFPH-M-125 .................K3

U217MTBPL...................D10

U3860...............................A1

U5168-XTL-200-KK..........C2

U9701-RXL.......................B8

UQFPH-M-150 .................K3

U224MTB .........................D6

U3822-20GR ....................A2

U5169-XTL-100................C2

UC1290-XL.......................F5

UQFPH-M-175 .................K3

U224MTB/22 ....................D7

U3852-XL .........................B7

U5169-XTL-150................C2

UC1291-RL.......................F5

UQFPH-M-200 .................K3

U224MTB-48....................D8

U3854-O-200 ...................C1

U5169-XTL-200................C2

UC1299-XL.......................F5

UQFP-M-100 ....................K3

U224MTBL .....................D10

U4015-KO ........................B5

U5200-XL .........................H5

UC1300-RL.......................F5

UQFP-M-125 ....................K3

U224MTB-P .....................D9

U4015-O...........................B4

U5200-XL-332..................H5

UC3423-XL.......................F6

UQFP-M-150 ....................K3

U224MTB-P48 .................D9

U4031-O-2/200 ................C4

U5200-XL-41....................H5

UC3425-XL.......................F6

UQFP-M-175 ....................K3

U224MTBPL...................D10

U4517-DL-M4...................B4

U5200-XL-75....................H5

UC3426-XL.......................F6

UQFP-M-200 ....................K3

U225MTB .........................D6

U4517-KO ........................B5

U5200-XL-75GB...............H5

UC3428-XL.......................F6

USE-AP-200-MB ..............C3

U225MTBL .....................D14

U4518-KO ........................B5

U5210-XL .........................H5

UC3433-XL.......................F6

USE-AP-200-ML ..............C3

U227MTB .........................D6

U4518-O-W ......................B4

U5220-XL .........................H5

UC3434-XL.......................F6

Z020-148-00-00-0..............I8

U227MTB/22 ....................D7

U4518-XL-W.....................B4

U5220-XL-41....................H5

UC3435-XL.......................F6

Z020-509-11-00-0..............I8

U227MTB-125................D14

U4540-XL .......................H12

U5220-XL-75....................H5

UC3436-XL.......................F6

Z818052-SC...................H18

U227MTB-150................D14

U4542-XL .......................H12

U5230-XL .........................H5

UC3438-XL.......................F6

Z818480-SC...................H18

U227MTB-175................D14

U4544-XL .......................H12

U5240-O ..........................G5

UC7233-XL.......................F5

Z915141-AC...................H18

U227MTB-48....................D8

U4546-XL .......................H12

U5240-O-100S.................G5

UC7235-XL.......................F5

Z917602-AC...................H18

U227MTBL .....................D10

U4548-RXL ....................H12

U5240-O-200S.................G5

UC7237-XL.......................F5

Z918447-SC...................H18

U227MTB-P .....................D9

U4549-RXL ....................H12

U5241-O ..........................G5

UC7461-YL-TGE-DES......F6

Z918449-SC...................H18

U227MTB-P48 .................D9

U4881-O-50GB ................A2

U5241-O-100S.................G5

UC7544-RL.......................F5

Z918466-AC...................H18

U227MTBPL...................D10

U4881-O-60GB ................A2

U5241-O-200S.................G5

UC7545-RL.......................F5

U2594-X .........................B11

U4908-O ............................I2

U5242-O-200S.................G5

UC7582-RL.......................F5

U2852-X .........................B15

U4908-O-11GR..................I2

U5243-O ..........................G5

UC7636-YL-TGE-DES......F6

U2853-X .........................B15

U4908-O-55GBGR ............I2

U5252-O ..........................G5

UQFB-100 ........................K4

L2

SECTION L

U2854-X .........................B15

TS10-0110........................F8

ALPHA-NUMERIC INDEX

TS10-0109........................F8

L2

L3

EUSERC INDEX

EUSERC INDEX

SECTION L

EUSERC INDEX

Milbank Catalog
EUSERC
Number
Drawing Number
U3574-RL-200
U3577-RL-200
U3584-O-200
U3587-O-200
U4015-O
UF4015-KO
U3548-X
M400-UG-APS-F
M400-UG-APS-F-BS
M400-UG-APS-P
M400-UG-APS-LC
M400-UG-APS-LC-BS
U3251-O-200-CB
M401-UG
M401-UG-BS
M404-UG-LC
M404-UG-LC-BS
114TB
115TB
117TB
124TB
125TB
127TB
214MTB
215MTB
217MTB
U214MTB
U215MTB
U217MTB
214MTB/22
217MTB/22
U214MTB/22
U217MTB/22
214MTB-48
215MTB-48
217MTB-48
U214MTB-48
U215MTB-48
U217MTB-48
214MTB-P
215MTB-P
217MTB-P
U214MTB-P
U215MTB-P
U217MTB-P
214MTB-P48
215MTB-P48
217MTB-P48
U214MTB-P48
U215MTB-P48
U217MTB-P48
224MTB
225MTB
227MTB
U224MTB
U225MTB
U227MTB
224MTB/22
227MTB/22
U224MTB/22

301
301
301
301
301A
301A
302B
302A
302
302A
302A
302
302
302A
302
302A
302
304, 311
304, 311
304, 311
305, 311
305, 311
305, 311
305A, 311
305A, 311
305A, 311
305A, 311
305A, 311
305A, 311
305A, 311
305A, 311
305A, 311
305A, 311
305A, 311
305A, 311
305A, 311
305A, 311
305A, 311
305A, 311
305A, 311
305A, 311
305A, 311
305A, 311
305A, 311
305A, 311
305A, 311
305A, 311
305A, 311
305A, 311
305A, 311
305A, 311
305A, 311
305A, 311
305A, 311
305A, 311
305A, 311
305A, 311
305A, 311
305A, 311
305A, 311

Catalog
Page
C1
C1
C1
C1
B4
B5
B11
C6
C6
C6
C6
C6
C6
C7
C7
C8
C8
D1
D1
D1
D1
D1
D1
D2
D2
D2
D2
D2
D2
D3
D3
D3
D3
D4
D4
D4
D4
D4
D4
D5
D5
D5
D5
D5
D5
D5
D5
D5
D5
D5
D5
D6
D6
D6
D6
D6
D6
D7
D7
D7

Milbank Catalog
EUSERC
Number
Drawing Number
U227MTB/22
227MTB-48
U224MTB-48
U227MTB-48
224MTB-P
225MTB-P
227MTB-P
U224MTB-P
U227MTB-P
224MTB-P48
225MTB-P48
227MTB-P48
U224MTB-P48
U227MTB-P48
U214MTBL
U214MTBPL
U217MTBL
U217MTBPL
U224MTBL
U224MTBPL
U227MTBL
U227MTBPL
PB-011
PB-012
PB-014
PB-014-NK
PB-018
PB-018-NK
PB-032
PB-034
PB-034-NK
PB-038
U3320-R
U3322-R
U3555-R
U3340-O
U3342-O
U3565-O
CT244811-SC
CT364811-SC
CT364814-SC
CT484811-SC
CT244811-HC
CT304811-HC
CT364811-HC
CT484811-HC
CT484814-HC
K4903
K4904
K4722
K4729
K4797
K4798
UC3435-XL
UC3436-XL
UC3438-XL
UC3433-XL
UC3434-XL

L3

305A, 311
305A, 311
305A, 311
305A, 311
305A, 311
305A, 311
305A, 311
305A, 311
305A, 311
305A, 311
305A, 311
305A, 311
305A, 311
305A, 311
305A, 311
305A, 311
305A, 311
305A, 311
305A, 311
305A, 311
305A, 311
305A, 311
343A
343A
343
343
343
343
343A
343
343
343
313
Single Phase Only
313
313
314
Single Phase Only
314
314
316, 317
316, 317, 318
316, 317, 318
316, 317
316, 317
316, 317
316, 317, 318
316, 317, 318
316, 317, 318
328B
329B
329B
328B
328A
329A
339
339
339
339
339

Catalog
Page
D7
D8
D8
D8
D9
D9
D9
D9
D9
D9
D9
D9
D9
D9
D10
D10
D10
D10
D10
D10
D10
D10
D11
D11
D11
D11
D11
D11
D11
D11
D11
D11
F4
F4
F4
F4
F4
F4
F2
F2
F2
F2
F2
F2
F2
F2
F2
F3
F3
F3
F3
F3
F3
F6
F6
F6
F6
F6

Meter Mounting Equipment & More!
Commercial Electrical Enclosures
Residential & Commercial Metering
Commercial Meter Pedestals
Disconnect Devices
Current Transformer Enclosures
RV/MH Pedestals
Temporary Power Outlets
Circuit Breakers
Enclosed Circuit Breakers
Safety Switches
Test Switches

REPRESENTED BY:

MILBANK MFG. CO.
PO Box 419028
Kansas City, MO 64141-0028
Tel: 816-483-5314 Fax: 816-483-6357
Toll Free: 877-483-5314
www.milbankmfg.com

www.milbankmfg.com

WRC 4/08 (5K)



Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.6
Linearized                      : Yes
XMP Toolkit                     : Adobe XMP Core 4.0-c316 44.253921, Sun Oct 01 2006 17:08:23
Trapped                         : False
GTS PDFX Version                : PDF/X-1:2001
GTS PDFX Conformance            : PDF/X-1a:2001
Producer                        : Acrobat Distiller 8.1.0 (Macintosh)
Create Date                     : 2009:01:06 21:01:08-06:00
Modify Date                     : 2009:01:06 21:08:45-06:00
Creator Tool                    : QuarkXPress 7.2
Metadata Date                   : 2009:01:06 21:08:45-06:00
Format                          : application/pdf
Creator                         : Kim Tappan
Title                           : WRC_4-08:UNY 1/03
Document ID                     : uuid:283545b8-613d-4b69-996a-25123c664ef8
Instance ID                     : uuid:4a14975b-c816-4556-a86c-7084d9e9b46f
Page Count                      : 128
Author                          : Kim Tappan
EXIF Metadata provided by EXIF.tools

Navigation menu