WRC_4 08 96747 Catalog
2014-07-05
: Pdf 96747-Catalog 96747-Catalog 784572 Batch5 unilog
Open the PDF directly: View PDF .
Page Count: 128
Download | |
Open PDF In Browser | View PDF |
Meter Mounting Equipment Western Region Area MILBANK OVERVIEW 1 MILBANK OVERVIEW Charles A. Milbank 1879-1966 Bill Martin 1916-1998 Robert F. Waldrop 1922-2002 Robert F. Waldrop, II Chairman Katrina Waldrop Henke Vice Chairman Milbank–Quality Metering Products for 80 Years M ilbank Manufacturing Company was established in 1927 by Charles A. Milbank. Originally, the company manufactured high voltage switches; however, by 1941 Milbank devoted itself primarily to the manufacture of sheet metal enclosures and related equipment for the electrical generation and distribution industry. Today we are an industry leader in the manufacture of electrical meter sockets. Through a national network of manufacturer ’s representatives we provide wholesale electrical distributors with quality electrical products for the utility, contractor, industrial and OEM markets. As the meter standards have changed, Milbank has been successful in adapting its product line to these changes. Our full scale engineering department designs products to meet customer specifications and satisfy all utility requirements. Milbank’s employee base of over 1,000 workers, along with our five manufacturing facilities comprising almost 550,000 square feet give us the flexibility to schedule, produce, and ship orders quickly. Currently, Milbank manufactures over 10,000 different catalog items, and this list continues to grow. Our unique product offering includes: Residential & Commercial Meter Sockets; Residential & Commercial Meter Pedestals; RV/MH Power Outlets, Service Pedestals, and Transformers; Commercial & Industrial Electrical Enclosures; Circuit Breakers; Disconnects & Safety Switches; Safety Sockets; Utility & Residential Secondary Pedestals; Hubs, and related accessories. If you don’t find a unit in this catalog to service your needs, send us your specifications and we will be happy to work with you. Our success has come from a loyal customer base that can rely on us to build quality products at a fair price in a timely manner. Our willingness and ability to design and produce new products 1 to meet our customer demands is an important factor to remain competitive in today’s electrical market. Milbank has been serving the electric utility & wholesale distribution industries for 80 years with innovative, quality engineered products. So remember us for all of your meter mounting and related requirements, and we will be happy to serve you as we have in the past – with dependable service and quality products! We take great pride in being one of the few family-owned businesses left in our industry. We are a third generation run business and truly believe that... FAMILY MAKES A DIFFERENCE! PRODUCT INDEX BY CATEGORY 2 PRODUCT INDEX BY CATEGORY AC DISCONNECTS SECTION A 30 & 60 Amp – Fusible/Non-Fusible Air Conditioner Disconnects....................................................................................1 Combination AC Disconnect / 20 Amp GFCI Receptacle..................................................................................................2 Hot Tub Disconnect or Sub Panel Breaker Enclosure – Type 3R .......................................................................................2 METER SOCKETS SECTION B SINGLE POSITION (NO BYPASS) 30-100 Amp – Economy Cast Socket – Ring Type, 4T.......................................................................................................1 125-200 Amp, Ringless, 4T, 5T & 7T.............................................................................................................................2-3 125-200 Amp, Ring Type, 4T & 7T................................................................................................................................2,4 125-200 Amp, Ring Type with Manual Circuit Closing Blocks, 4T & 7T ...........................................................................9 200 Amp, Ring Type, Flush Mount, 4T .............................................................................................................................5 320 Amp, Ringless (Non-Lever Bypass), 4T.....................................................................................................................10 SINGLE POSITION (WITH BYPASS) 125-200 Amp, Ringless (Non-Jaw Clamping Lever Bypass), 4T, 5T & 7T .......................................................................6-7 200 Amp, Ringless (Jaw Clamping Lever Bypass), 4T, 5T & 7T .........................................................................................8 320 Amp, Ringless (Lever Bypass), 4T.............................................................................................................................10 320 Amp, Ring Type (Link Bypass), 4T ...........................................................................................................................11 320 Amp, Ringless (Lever Bypass), Side Wireway, 7T .....................................................................................................11 MULTIPLE POSITION 100-125 Amp, Ringless/Ring Type Horizontal Gang Sockets, 4T ....................................................................................12 200 Amp, Ringless/Ring Type Horizontal Gang Sockets, 4T ...........................................................................................13 125-200 Amp, Condominium Metering Banks, Ringless ............................................................................................15-16 METER MAINS AND SERVICE ENTRANCE EQUIPMENT SECTION C 100/150/200 Amp, Ringless/Ring Type Meter Main, 4T & 5T – 22K AIC...........................................................................2 200 Amp, Ring Type, 4T & 7T ..........................................................................................................................................1 200 Amp, Unmetered, Service Entrance Main Breaker, 4T ...............................................................................................3 400 Amp, 320 Amp Continuous, Ringless Meter Main with Split Load, 4T .......................................................................4 400 Amp, 320 Amp Continuous, Ring Type Meter Main with Split Load, 4T ....................................................................5 400 Amp, 320 Amp Continuous, Ring Type Plug-In Socket – Meter Main with Split Load, 4T ..........................................6 400 Amp, 320 Amp Continuous, Ring Type Meter Main Combination, 4T ....................................................................7-8 COMMERCIAL METERING – SAFETY SOCKETS, METER MAINS, TERMINATION BOXES, BUSSED GUTTERS SECTION D SAFETY SOCKETS 100/200 Amp – TB Series – 600 Volt Self-Contained / Socket Only, 4T, 5T & 7T..............................................................1 100 Amp, MTB Series – 10K AIC – 240 Volt Self-Contained Meter Main / CB, 4T, 5T & 7T..............................................2 100 Amp, MTB Series – 22K AIC – 240 Volt Self-Contained Meter Main / CB, 4T & 7T....................................................3 100 Amp, MTB Series – 14K AIC – 480 Volt Self-Contained Meter Main / CB, 4T, 5T & 7T..............................................4 100 Amp, MTB-P & MTB-P48 Series – 200K AIC – 240 & 480 Volt Self-Contained Meter Main / T-Fuse Pullout, 4T, 5T & 7T.........................................................................................................................................5 200 Amp, MTB Series – 10K AIC – 240 Volt Self-Contained Meter Main / CB, 4T, 5T & 7T..............................................6 200 Amp, MTB Series – 22K AIC – 240 Volt Self-Contained Meter Main / CB, 4T & 7T....................................................7 200 Amp, MTB Series – 35K AIC – 480 Volt Self-Contained Meter Main / CB, 4T & 7T....................................................8 200 Amp, Test Block Bypass – MTB-P & MTB-P48 Series – 200K AIC – 240/480 Volt Self-Contained Meter Main / T-Fuse Pullout, 4T, 5T & 7T.........................................................................................................................................9 100 & 200 Amp, MTBL All-In-One Series, 10K & 200K AIC – 240 Volt Meter Main – Circuit Breaker / T-Fuse Pullout ................................................................................................................................................................10 Safety Socket Replacement Circuit Breakers & Pullouts .............................................................................................14-15 Safety Socket & T-Fuse Replacement Parts ......................................................................................................................16 UNDERGROUND TERMINATION BOXES & BUSSED GUTTERS Underground Termination Boxes – 600 VAC..................................................................................................................11 Bussed Gutters – Type 3R - 3Ø4W – 600 VAC ...............................................................................................................12 Bussed Gutters – Type 3R - 3Ø4W – 600 VAC ...............................................................................................................13 COMMERCIAL METER PEDESTALS SECTION E Commercial Meter Pedestals Overview ............................................................................................................................1 Applications & Accessories...............................................................................................................................................2 Catalog Number Logic......................................................................................................................................................3 ML Series – Main Load Center ..........................................................................................................................................4 SL Series – Switched Load Center .....................................................................................................................................5 400 Amp Series ................................................................................................................................................................6 IR Series – Irrigation Control .............................................................................................................................................7 BBS/UPS Series .................................................................................................................................................................8 2 PRODUCT INDEX BY CATEGORY CT CABINETS, TEST SWITCHES, POLYPHASE ENCLOSURES SECTION F Current Transformer Cabinets – Type 3R – Door Mount CT Rated Socket .........................................................................1 Current Transformer Cabinets ...........................................................................................................................................2 Current Transformer Cabinets – Mounting Racks ..............................................................................................................3 Metered Transformer Cabinets – Overhead & Underground .............................................................................................4 20 Amp – 4, 5, 6, 7, 8 & 13 Terminal Current Transformer Rated – Ringless/Ring Type ....................................................5 20 Amp – 600 VAC – 5, 6, 8, 13 & 15 Terminal Current Transformer – Test Switch Provision ..........................................6 Milbank Test Switches – 4, 7 & 10 Pole............................................................................................................................7 Test Switches – 4, 7 & 10 Pole – 600 VAC – Per ANSI C12.9 Standard.............................................................................8 Milbank Test Switch Worksheet........................................................................................................................................9 SERVICE PEDESTALS SECTION G 125 Amp – Mobile Home Metered Pedestal – Hardwired – 120/240VAC .........................................................................1 200 Amp – Mobile Home Metered Pedestal – Hardwired – 120/240VAC .........................................................................2 100/200 Amp – Load Center Power Pedestals – All Purpose & RV Applications ...............................................................3 200 Amp Series U5240 & U5241 Ring Type Metered Pedestals ....................................................................................4-5 200 Amp Series U5136 & 5137 Ringless Metered Pedestals ..........................................................................................6-7 U5706 & U5707 Temp to Final Service Pedestal – Ringless/Ring Type ..........................................................................8-9 Mobile Home Rebuild Kits ........................................................................................................................................10-11 RV SECTION H Series U5000 – Unmetered – Surface Mount Power Outlet ...........................................................................................1-2 Series U5100 – Metered – Surface Mount Power Outlet ................................................................................................3-4 Series U5200 – Unmetered – Pedestal Power Outlet .....................................................................................................5-6 Series U5300 – Metered – Pedestal Power Outlet ..........................................................................................................7-8 Millennium Features....................................................................................................................................................9-10 600/1200 Amp – Pad Mounted Panel Board...................................................................................................................11 100, 200 & 400 Amp – Terminal Box .............................................................................................................................12 Lighting Accessories .......................................................................................................................................................13 Telecommunications and Pedestal Accessories...............................................................................................................14 Pedestal Mounting Accessories.......................................................................................................................................15 Metering & Single Receptacle Accessories ......................................................................................................................16 RV Replacement Parts & Accessories.........................................................................................................................17-18 RV Product Information – Wiring Diagram Label – Warranty.........................................................................................19 TEMPORARY POWER SECTION I U4908/U4909 Underground Service Power Outlet – Ringless/Ring Type ......................................................................1-2 Series U5000 – Unmetered – Surface Mount Power Outlet ...........................................................................................3-4 Series U5001 – Unmetered – Surface Mount Power Outlet...............................................................................................5 Series U5100 & U5101 Overhead – Ringless/Ring Type – Metered – Surface Mount Power Outlet ...............................6-7 Replacement Parts for MPAP/MPRV/HP Pedestals ............................................................................................................8 TRANSFORMERS SECTION J Galvanized Steel Distribution Transformer – 1∅...............................................................................................................1 MISCELLANEOUS SECTION K Accessories....................................................................................................................................................................1,2 UQFP Plug-In Series Circuit Breakers ...............................................................................................................................3 UQFB Bolt-On Series Circuit Breakers ..............................................................................................................................4 Conduit, Ampacity, SCCR Information..............................................................................................................................5 Energization of Electrical Equipment.................................................................................................................................6 Materials and Finishes ......................................................................................................................................................7 Meter Forms .....................................................................................................................................................................8 Watthour Meter Forms – Standard Forms, Transformer Rated or Self-Contained ...............................................................9 Standard NEMA Configurations ......................................................................................................................................10 Additional Milbank Products ..........................................................................................................................................11 ALPHA-NUMERIC INDEX SECTION L Alpha-Numeric Index ....................................................................................................................................................1-2 3 PRODUCT INDEX BY CATEGORY Power Transfer Series – Metered & Unmetered .................................................................................................................9 General Specifications ....................................................................................................................................................10 Commercial Meter Pedestal Drawings – 16” Metered & Unmetered ...............................................................................11 Commercial Meter Pedestal Drawings – 24” Metered & Unmetered ...............................................................................12 Commercial Meter Pedestal Drawings – 32” Metered .....................................................................................................13 Commercial Meter Pedestal Drawings – Metered ...........................................................................................................14 3 CATALOG NUMBER LOGIC CATALOG NUMBER LOGIC 4 4 30 & 60 AMP–FUSIBLE / NON-FUSIBLE–AIR CONDITIONER DISCONNECTS A1 SECTION A AC DISCONNECTS U3801 U3800 U3860 (No deadfront required) PROFILE Milbankʼs air conditioner disconnect has a removable hinged cover which makes wiring a breeze. Our compact design meets all wire bending space requirements in the NEC and, also, complies with article 440-14 in the NEC. To insure the safest conditions, we designed our disconnect pullers to be removable or they may be reinstalled in the off position. Another safety feature is the padlock provision on the front cover. As with all Milbank products, our enclosure is constructed of G90U galvanized steel and finished with an attractive, light gray, baked powder coating. Our state of the art finish combines epoxy and polyester hybrid resins into a hybrid powder coating which is then electrostatically applied. This offers a durable, nonfading finish. TECHNICAL INFORMATION AMP TYPE CATALOG NUMBER MAX WT. H.P. @ # 30 FUSIBLE U3830 3 2.7 60 FUSIBLE U3860 10 3.3 60 NONFUSIBLE U3800 10 3.25 60 NONFUSIBLE U3801 10 2.5 LINE & LOAD WIRE RANGE GROUND WIRE RANGE DIMENSIONS WIRE RATING CU °C CU AL CU/AL D" W" H" #14-#3 AWG #14-#3 AWG #14-#2 AWG #14-#3 AWG #14-#3 AWG #14-#3 AWG #12-#2 AWG #14-#3 AWG #14-3 AWG 2-5/8 5 7 #14-3 AWG 3 5 #14-3 AWG 3 5 #14-3 AWG 2-3/8 5 AL °C 60°/75° 60°/75° 91⁄4 60°/75° 60°/75° 8 60°/75° 60°/75° 6-3/4 60°/75° 60°/75° U/L listed as Enclosed Pullout Switch Type 3R Rainproof 1∅, 240 VAC Six one-inch concentric knockouts Utility requirements for this equipment may vary. Always consult the serving utility for their requirements before ordering or installing equipment in this catalog. A1 AC DISCONNECT / SPA BOX Combination AC Disconnect / 20 Amp GFCI Receptacle–Together in 1 Box SECTION A A2 • Meets NEC # 210.63 Requirements * • UL Listed as Power Outlet • Type 3R Enclosure • In-Use Cover** • Duplex Ground Connector • 1” Concentric Knockouts * AC DISCONNECTS 60 amp, Non-Fused AC Disconnect AC DISCONNECT • 1∅, 240 Volt • 60 amp, Non-Fused Duplex 20 amp GFCI Receptacle Type 3R Enclosure with In-Use Cover GFCI RECEPTACLE • 20 amp • Reset/Test Button • Padlock provision U3822-20GR AMP 60 TYPE CATALOG MAX WT. NUMBER H.P. # NONFUSIBLE U3822-20GR 10 LINE & LOAD CONNECTOR WIRE RANGE 6 NEC® #210.63 Heating, AirConditioning and Refrigeration Equipment Outlet. ...The receptacle shall be located on the same level and within 7.5 m (25 ft.) of the heating, air-conditioning and refrigeration equipment. * NEC® #210.08 Ground-Fault Circuit– Interruptor protection for personnel. GROUND CONNECTOR WIRE RANGE DIMENSIONS WIRE RATING CU °C W" H" AL °C CU AL CU/AL D" #14-#2 #12-#2 #14-4 4.8 5.25 7.4 60°/75° 60°/75° To ensure the safest conditions, Milbank disconnect pullers are designed to be reversible so they may be reinstalled in the OFF position. All units are designed with a padlock provision on the cover for security. **Note: U3822-20GR cover rated as IN-USE COVER (Cover may be closed with cords plugged into receptacle). *Reprinted with permission from NFPA 70-2002, National Electrical Code®, Copyright 2001, National Fire Protection Association, Quincy, MA 02269. This reprinted material is not the complete and official position of the NFPA on the referenced subject, which is represented only by the standard in its entirety. National Electrical Code® and NEC® are registered trademarks of the National Fire Protection Association, Quincy, MA. Hot Tub Disconnect or Sub Panel Breaker Enclosure–Type 3R Spa Box with GFCI Protection • • • • • • • • • • • 240 volt ground fault protection UL listed, Type 3R rainproof Milbank reliability Easy installation 2 pole, 50 amp GFCI breaker protection Compact size: 8-1/2” H x 7-1/2” W x 3-3/4” D 3 or 4 wire installation 1∅, 120 / 240 VAC Standard package of 12 2 extra one-pole breaker spaces 100 amp overall rating Sub Panel Breaker Enclosure • Use as a 100 amp, 4 circuit sub panel enclosure U4881-O-50GB AMP TYPE CATALOG NUMBER WT. # LINE & LOAD CONNECTOR WIRE RANGE GROUND CONNECTOR WIRE RANGE DIMENSIONS CU AL CU/AL D" W" H" 50 BREAKER U4881-O-50GB 8 #14-1/0 #14-1/0 #14-1/0 3 3⁄4 71⁄2 81⁄2 60 BREAKER U4881-O-60GB 8 #14-1/0 #14-1/0 #14-1/0 3 3⁄4 71⁄2 81⁄2 A2 30/60/100 AMP—4 TERMINAL—ECONOMY CAST SOCKET—RING TYPE B1 ECONOMY SOCKET Temporary Service Outdoor Advertising Small Customer Service Other Low Amperage Requirements SECTION B 100 amp max rated is ideal for use on: METER SOCKETS FOR USE WITH SINGLE PHASE SELF-CONTAINED 4 TERMINAL METERS Our enclosure is made of die cast aluminum. The electrostatically applied epoxy and polyester resins, which are baked on, form a durable, light gray exterior. The current carrying parts are of copper alloy. The ground connector is designed to insure a positive electrical connection by effectively clamping the conductor against a serrated surface. 30-100 AMP—4 TERMINAL—ECONOMY CAST SOCKET—RING TYPE SERVICE CATALOG NUMBER HUB SIZE CONNECTOR CU/AL QUANTITY PER PACKAGE CONCENTRIC KNOCKOUTS OH/UG AP2300-03 1" #12-#1 12 3/4", 1" OH/UG AP2300-04 11⁄4" #12-#1 12 3/4", 1" FIFTH & SIXTH TERMINAL: Contact factory. SEALING RING: Supplied with a snap action sealing ring. HUB: Units supplied with cast in hub on top and bottom. Consult factory for availability of other hub sizes. BYPASS: Also available with auto bypass. Contact factory. Utility requirements for this equipment may vary. Always consult the serving utility for their requirements before ordering or installing equipment in this catalog. B1 125 AMP—4 & 7 TERMINAL—SINGLE POSITION—RINGLESS / RING TYPE—600 VAC SECTION B B2 1 2 7490 4 3 4 METER SOCKETS 5 1 2 4 3 4 5 6 6 7487 6 1 U7487-RL 2 U7490-O 1681 3 5 6 125 AMP–SINGLE POSITION–4 TERMINAL–RINGLESS AMP 125 125 SERVICE UG OH/UG CATALOG NUMBER HUB U7487-O BLANK U7487-RL H.O. CONNECTORS CU/AL #6-2/0 #6-2/0 DIMENSIONS D" W" 5 8 ⁄16 3 5 ⁄16 3 8 CONCENTRIC K.O.ʼS H" 11 1 11 1 ⁄2 ⁄2 1 2 3 4 5 1 11⁄2 2 11⁄4 1 1 — — 1 1 ⁄2 ⁄2 1 ⁄2 2 11⁄4 6 1 ⁄4 1 ⁄4 125 AMP–SINGLE POSITION–4 TERMINAL–RING TYPE AMP 125 125 SERVICE OH/UG UG CATALOG NUMBER U7490-RL U7490-O HUB H.O. BLANK CONNECTORS CU/AL #6-2/0 #6-2/0 DIMENSIONS D" 5 ⁄16 3 5 ⁄16 3 W" 8 8 CONCENTRIC K.O.ʼS H" 1 11 1 1 11⁄2 11 1 1 1 ⁄2 ⁄2 1 1 ⁄2 ⁄2 2 1 ⁄2 3 4 2 11⁄4 2 1 1 ⁄4 5 — — 6 1 ⁄4 1 ⁄4 125 AMP–7 TERMINAL–RING TYPE AMP 125 SERVICE OH CATALOG NUMBER HUB U1681-RL H.O. CONNECTORS CU/AL #6-2/0 DIMENSIONS D" W" 7 10 4 ⁄8 CONCENTRIC K.O.ʼS H" 18 1 ⁄2 1 2 3 4 5 2 2 2 — 1 1 4, 2 ⁄ ⁄ 6 3 ⁄4 FIFTH TERMINAL: For field mounted fifth terminal on the U7487 & U7490 order catalog number 5T8K2 to fit into round opening at the 9 oʼclock position. HUBS: For proper hub selection see the hub suffix chart on the accessory page. CONNECTORS: Extruded aluminum connectors are tin plated. SEALING RINGS: Ring type units supplied with an MR-2 snap action sealing ring as standard. Utility requirements for this equipment may vary. Always consult the serving utility for their requirements before ordering or installing equipment in this catalog. B2 200 AMP—4 TERMINAL—SINGLE POSITION—RINGLESS—600 VAC B3 SECTION B METER SOCKETS U7040-XL-TG 1 2 4 3 4 5 U1060-RL 1 1 2 2 7040 1060 7021 6 5 3 6 3 1980 5 4 6 200 AMP–SINGLE POSITION–4 TERMINAL–RINGLESS AMP 200 200 SERVICE OH UG CATALOG NUMBER U1060-RL U1527-O HUB H.O. BLANK CONNECTORS CU/AL #2-350 #2-350 DIMENSIONS D" 1 4 ⁄8 1 4 ⁄8 W" 8 11 CONCENTRIC K.O.ʼS H" 1 15 1 15 1 2 2 ⁄2 ⁄2 2 2 1 1 2 1 2 13 15 1 1 8 15 1 2 2 UG U1980-O BLANK #6-350 4 200 OH U7021-RL-TG H.O. #6-350 4 ⁄2 ⁄8 ⁄4 ⁄2 1 11 15 1 7 13 15 1 200 OH/UG U7040-XL-TG C.P. #6-350 4 200 OH/UG U7043-XL-TG C.P. #6-350 4 ⁄8 ⁄8 ⁄2 ⁄2 2 2 1 200 2 ⁄2 ⁄2 1 1 2 1 2 ⁄2 ⁄2 ⁄2 ⁄2 1 ⁄2 1 ⁄2 3 4 — ⁄2 1 1 4, 2 1 1 — 2 1 ⁄ ⁄ 3 1 1 ⁄2 2 1 — 1 1 1 2 2 ⁄2 ⁄2 3 2 6 1 2 2 5 ⁄2 3 ⁄2 ⁄4 1 1 4, 2 ⁄ ⁄ 1 ⁄4 ⁄4 ⁄4 1 1 4, 2 ⁄ ⁄ 1 1 4, 2 ⁄ ⁄ 1 ⁄4 1 1 4, 2 ⁄ ⁄ FIFTH TERMINAL: For field mounted fifth terminal order catalog number K5T to fit into square opening at the 9 oʼclock position. HUBS: For proper hub selection see the hub suffix chart on accessory page. CONNECTORS: Extruded aluminum connectors are tin plated. Utility requirements for this equipment may vary. Always consult the serving utility for their requirements before ordering or installing equipment in this catalog. B3 200 AMP—4 & 7 TERMINAL—SINGLE POSITION—RING TYPE—600 VAC METER SOCKETS SECTION B B4 U4518-O-W U3328-RXL 1 3328 4 3 4 5 1 2 6 5 3 2 1 3 3 4 4518 6 5 1 2 4517 3 6 2 4015 5 4 6 200 AMP–SINGLE POSITION–4 TERMINAL–RING TYPE AMP 200 SERVICE OH CATALOG NUMBER HUB U4517-DL-M4 2" CONNECTORS CU/AL #6-350 DIMENSIONS D" W" 1 8 1 11 15 1 16 1 #6-350 4 200 UG U4518-O-W BLANK #6-350 4 #6-350 ⁄2 15 C.P. BLANK 1 11 U4518-XL-W U4015-O 15 1 OH/UG UG H" 1 200 200 ⁄8 4 CONCENTRIC K.O.ʼS ⁄8 ⁄8 6 14 ⁄2 ⁄2 ⁄4 1 2 3 4 21⁄2 21⁄2 21⁄2 — 5 1 ⁄4 6 1 1 4, 2 ⁄ ⁄ 2 2 2 21⁄2 1 1 4, 2 ⁄ ⁄ 1 2 2 2 21⁄2 1 1 4, 2 1 21⁄2 21⁄2 3 11⁄2 ⁄ ⁄ 21⁄2 ⁄4 ⁄4 1 1 4, 2 ⁄ ⁄ 200 AMP–7 TERMINAL–RING TYPE AMP 200 SERVICE OH/UG CATALOG NUMBER HUB U3328-RXL C.P. CONNECTORS CU/AL #6-350 DIMENSIONS CONCENTRIC K.O.ʼS D" W" H" 1 2 3 4 5 7 13 19 3 21⁄2 3 3 1 4 ⁄8 ⁄4 6 1 1 4, 2 ⁄ ⁄ FIFTH TERMINAL: For field mounted fifth terminal order catalog number K5T to fit into square opening at the 9 oʼclock position. HUBS: For proper hub selection see the hub suffix chart on the accessory page. CONNECTORS: Extruded aluminum connectors are tin plated. SEALING RINGS: The above ring type units are supplied with an MR-4 screw type sealing ring as standard. Utility requirements for this equipment may vary. Always consult the serving utility for their requirements before ordering or installing equipment in this catalog. B4 200 AMP—4 TERMINAL–FLUSH MOUNT—SINGLE POSITION–RING TYPE—600 VAC B5 SECTION B 3 4 METER SOCKETS UF4015-KO UF4518-KO 4 3 4 3 1 1 1 2 2 2 4015 4969 4 5 3 6 4518 3 4517 3 4 5 4 6 5 4 6 200 AMP—4 (1∅3W) TERMINAL—FACTORY WELDED FLUSH MOUNT—RING TYPE TERM. AMP SERVICE 4 4 4 4 200 200 200 200 OH OH/UG UG UG CATALOG NUMBER UF4517-KO UF4518-KO UF4015-KO UF4969-KO* HUB CONNECTORS CU/AL K.O. K.O. K.O. K.O. #6-350 #6-350 DIMENSIONS D" 1 ⁄8 5 1 ⁄8 5 #6-350 5 #6-350 1 7 ⁄2 W" 8 11 14 14 CONCENTRIC K.O.ʼS H" 15 1 15 1 16 1 16 1 ⁄2 ⁄2 ⁄4 ⁄4 1 2 2 1 2 ⁄2 1 2 ⁄2 2 3 2 2 2 1 2 1 2 2 ⁄2 1 2 ⁄2 ⁄2 1 ⁄2 1 2 ⁄2 4 2 2 1 2 ⁄2 3 5 1 ⁄4 ⁄ ⁄ 1 1 4, 2 6 ⁄ ⁄ 1 1 4, 2 1 ⁄4 1 1 1 4, 2 1 1 1 4, 2 1 1 ⁄2 ⁄2 ⁄ ⁄ ⁄ ⁄ FIFTH TERMINAL: For field mounted fifth terminal order catalog number K5T to fit into square opening at the 9 oʼclock position. CONNECTORS: Extruded aluminum connectors are tin plated. SEALING RINGS: Ring type units supplied with an MR-4 screw type sealing ring as standard. * UF4969 can only be used in a 2 x 6 wall. Utility requirements for this equipment may vary. Always consult the serving utility for their requirements before ordering or installing equipment in this catalog. B5 200 AMP—4 & 5 TERMINAL—SINGLE POSITION—RINGLESS NON-JAW CLAMPING LEVER BYPASS—600 VAC METER SOCKETS SECTION B B6 2 1 2 1 4 5 3 6 3852 4 3 4 1211 9319 4 5 6 U9319-XL 200 AMP—4 TERMINAL—RINGLESS—1∅3W CONNECTORS TERM SERVICE 4 OH/UG CATALOG NUMBER U3852-XL HUB CU/AL LINE & LOAD C.P. #2-350 BYPASS LEVER DIMENSIONS D" 7 4 ⁄8 W" 13 H" 19 CONCENTRIC K.O.ʼS 1 2 3 4 5 3 1 1 1 1 2 ⁄2 2 ⁄2 2 ⁄2 ⁄4 6 1 1 4, 2 ⁄ ⁄ FIFTH TERMINAL: Fifth terminal is not available for this unit. TRIPLEX GROUND: Factory installed as standard. 200 AMP—4 & 5 TERMINAL—RINGLESS—1∅3W OR 3∅3W CONNECTORS TERM SERVICE 4 5 OH/UG OH/UG CATALOG NUMBER HUB U1211-RXL C.P. U9319-XL CU/AL LINE & LOAD C.P. #6-350 BYPASS LEVER #6-350 LEVER DIMENSIONS CONCENTRIC K.O.ʼS D" W" H" 1 7 13 19 3 4 ⁄8 7 4 ⁄8 13 19 3 2 3 4 5 1 3 3 1 1 1 4, 2 3 1 1 1 4, 2 2 ⁄2 1 2 ⁄2 3 ⁄4 ⁄4 6 ⁄ ⁄ FIFTH TERMINAL: For field mounted fifth terminal, order as extra K3866 for the U1211. HUBS: For proper hub selection see the hub suffix chart on the accessory page. BYPASS: 200 amp continuous duty bypass. Lever operates bypass only. Not jaw clamping. CONNECTORS: Units are supplied with extruded aluminum connectors and bonded, triplex neutral. Utility requirements for this equipment may vary. Always consult the serving utility for their requirements before ordering or installing equipment in this catalog. B6 ⁄ ⁄ 125-200 AMP–7 TERMINAL–SINGLE POSITION–RINGLESS NON-JAW CLAMPING LEVER BYPASS–600 VAC SECTION B 6 1 2 6 7573 8100 1 2 3 9320 7422 7423 METER SOCKETS 3 5 U7423-RXL U7573-RL 4 5 4 6 125 AMP—7 TERMINAL—RINGLESS—3∅4W AMP SERVICE CATALOG NUMBER HUB CONNECTORS CU/AL BYPASS DIMENSIONS D" W" H" 10 18 1 7 10 18 1 OH U7573-RL H.O. #6-2/0 LEVER 4 125 OH U8100-RL H.O. #6-2/0 NONE 4 OH/UG U9320-RXL C.P. #6-2/0 LEVER CONCENTRIC K.O.ʼS 7 125 125 ⁄8 ⁄8 7 4 ⁄8 13 ⁄2 ⁄2 19 1 2 3 2 2 2 2 2 2 3 1 ⁄2 2 3 4 5 — — 1 1 4, 2 ⁄ ⁄ 3 1 1 4, 2 3 3 ⁄ ⁄ 1 ⁄4 6 ⁄4 ⁄4 1 1 4, 2 ⁄ ⁄ 200 AMP—7 TERMINAL—RINGLESS—3∅4W AMP 200 200 SERVICE OH/UG OH/UG CATALOG NUMBER U7422-RXL U7423-RXL HUB C.P. C.P. CONNECTORS CU/AL BYPASS #6-350 NONE #6-350 LEVER DIMENSIONS D" 7 4 ⁄8 7 4 ⁄8 W" 13 13 H" 19 19 CONCENTRIC K.O.ʼS 1 2 3 1 3 2 ⁄2 1 2 ⁄2 3 3 3 4 5 3 1 1 1 4, 2 3 1 1 1 4, 2 ⁄4 ⁄4 6 ⁄ ⁄ ⁄ ⁄ HUBS: For proper hub selection, see hub suffix chart in accessories page. BYPASS: 200 amp continuous duty bypass. Lever operates bypass only. Not jaw clamping. CONNECTORS: Extruded aluminum connectors are tin plated. Units supplied with bonded, duplex neutral. Utility requirements for this equipment may vary. Always consult the serving utility for their requirements before ordering or installing equipment in this catalog. B7 B7 200 AMP—4, 5 & 7 TERMINAL—SINGLE POSITION—RINGLESS JAW CLAMPING LEVER BYPASS–600 VAC METER SOCKETS SECTION B B8 U9701-RXL U9800-RRL U9551-RXL 6 1 5 6 1 2 3 6 9550 9700 5 3 6 2 1 2 9800 3 4 5 9551 9701 4 6 200 AMP—4 TERMINAL—RINGLESS—1∅3W OR 3∅3W AMP SERVICE 200 200 CATALOG NUMBER OH U9800-RRL OH/UG U9801-RXL HUB H.O. C.P. CONNECTORS BYCU/AL PASS #6-350 #6-350 LEVER LEVER DIMENSIONS D" 7 ⁄8 4 7 ⁄8 4 CONCENTRIC K.O.ʼS W" H" 10 1 13 18 ⁄2 19 1 3 3 2 1 ⁄2 2 1 ⁄2 2 3 3 3 4 — 3 5 1 1 4, 2 ⁄ ⁄ 1 ⁄4 6 3 ⁄4 1 1 4, 2 ⁄ ⁄ 200 AMP—5 TERMINAL—RINGLESS—1∅3W OR 3∅3W AMP SERVICE 200 200 OH OH/UG CATALOG NUMBER HUB U9550-RRL H.O. U9551-RXL C.P. CONNECTORS BYCU/AL PASS #6-350 #6-350 LEVER LEVER DIMENSIONS D" W" 7 10 ⁄8 4 7 ⁄8 4 13 CONCENTRIC K.O.ʼS H" 18 1 ⁄2 19 1 3 3 2 3 4 5 1 3 — 1 1 4, 2 ⁄2 2 1 ⁄2 2 3 3 ⁄ ⁄ 1 ⁄4 6 3 ⁄4 1 1 4, 2 ⁄ ⁄ 200 AMP—7 TERMINAL—RINGLESS—3∅4W AMP SERVICE CATALOG NUMBER HUB CONNECTORS CU/AL BYPASS DIMENSIONS D" CONCENTRIC K.O.ʼS W" H" 7 10 1 7 13 200 OH U9700-RRL H.O. #6-350 LEVER 4 200 OH/UG U9701-RXL C.P. #6-350 LEVER 4 ⁄8 ⁄8 18 ⁄2 19 1 2 3 1 2 3 2 1 ⁄2 ⁄2 3 4 5 3 — 1 1 4, 2 3 3 ⁄ ⁄ 1 ⁄4 6 3 ⁄4 1 1 4, 2 ⁄ ⁄ HUBS: For proper hub selection, see hub suffix chart in accessories page. BYPASS: Lever supplies clamping action and also operates bypass device. CONNECTORS: Extruded aluminum connectors are tin plated. U9550 and U9551 units are supplied with duplex neutral, with removable bonding strap for insulated neutral. U9700 series units are supplied with duplex neutral. Internal Hex Connectors. For main and/or service disconnect, use with U5484-O enclosed circuit breaker. Utility requirements for this equipment may vary. Always consult the serving utility for their requirements before ordering or installing equipment in this catalog. B8 125-200 AMP—4 & 7 TERMINAL MANUAL CIRCUIT CLOSING BLOCKS—RING TYPE—600 VAC B9 SECTION B 3 4 5 METER SOCKETS 2 1 4 6 3504 3507 3514 3517 U3517-XL U3504-XL 125 AMP—RING TYPE TERM. 4 7 SERVICE OH/UG OH/UG CATALOG NUMBER U3504-XL U3507-XL HUB C.P. C.P. CONNECTORS BYCU/AL PASS LINK #6-2/0 LINK #6-2/0 DIMENSIONS D" 7 ⁄8 4 7 ⁄8 4 CONCENTRIC K.O.ʼS W" H" 1 2 3 4 5 10 1 2 2 2 2 — 1 2 1 — 10 18 ⁄2 21 2 2 2 ⁄4 6 ⁄4 200 AMP—RING TYPE TERM. 4 7 SERVICE OH/UG OH/UG CATALOG NUMBER HUB U3514-XL C.P. U3517-XL C.P. CONNECTORS BYCU/AL PASS LINK #6-350 LINK #6-350 DIMENSIONS CONCENTRIC K.O.ʼS D" W" H" 7 13 21 13 1 4 ⁄8 7 4 ⁄8 24 ⁄2 1 1 2 ⁄2 1 2 ⁄2 2 3 4 5 6 1 3 3 1 1 1 1 1 1 1 2 2 ⁄2 ⁄2 2 ⁄2 2 ⁄2 ⁄4 ⁄4 ⁄2 ⁄2 FIFTH TERMINAL: For field mounted fifth terminal order catalog number 5T8K2 for the U3504; order K5T for the U3514. CONNECTORS: Extruded aluminum connectors are tin plated. SEALING RINGS: Ring type units supplied with an MR-4 screw type sealing ring as standard. LINK BYPASS: Links provided by utility. Utility requirements for this equipment may vary. Always consult the serving utility for their requirements before ordering or installing equipment in this catalog. B9 B10 320 AMP—4 TERMINAL—SINGLE POSITION—RINGLESS—600 VAC METER SOCKETS SECTION B 400 AMP MAX 320 AMP CONTINUOUS 2 1 4 5 3 1129 1797 1819 4 6 2 1 3 3 1079 1432 1431 4 5 6 U1797-O-K3L-K2L U1129-O-K3L-K2L 320 AMP—4 TERMINAL—RINGLESS—600 VAC AMP SVC. 320 320 OH UG 320 OH/UG 320 320 320 UG UG UG CATALOG NUMBER U1079-R U1129-O-K3L-K2L U1431-R* U1432-O* U1819-X* U1797-O-K3L-K2L FIFTH TERM. CONNECTORS LINE 3 ⁄8"-16 STUDS K3866 H.O. K3865 BLANK #4-600 or (2) 1/0-250 K3866 K3865 DIMENSIONS BYLOAD PASS D" W" H" CONCENTRIC K.O.ʼS CU/AL HUB H.O. 3 BLANK 3 TWIN #6-350 ⁄8"-16 STUDS ⁄8"-16 STUDS 3 ⁄8"-16 STUDS K3865 C.P. K3865 BLANK #4-600 or (2) 1/0-250 TWIN #6-350 LEVER LEVER NONE NONE NONE LEVER 7 4 ⁄8 7 4 ⁄8 7 4 ⁄8 13 30 13 38 3 29 3 13 7 15 4 ⁄8 ⁄8 7 4 ⁄8 ⁄4 15 7 4 38 3 15 ⁄4 ⁄4 30 30 1 3 2 3 4 5 1 3 3 1 1 1 4, 2 1 1 4, 2 2 3 3 1 3 3 1 1 1 4, 2 1 1 4, 2 3 2 3 ⁄ ⁄ 1 2 3 ⁄4 1 3 3 ⁄2 6 ⁄2 ⁄2 ⁄4 ⁄4 ⁄ ⁄ ⁄ ⁄ 1 3 3 1 3 3 3 1 1 1 4, 2 3 1 1 1 4, 2 2 ⁄2 3 3 ⁄4 ⁄4 ⁄4 ⁄ ⁄ ⁄ ⁄ ⁄ ⁄ HUBS: For proper hub selection, see hub suffix chart in accessories page. BYPASS: *Lever supplies clamping action on meter spades only on the U1431, U1432 and U1819. Lever supplies clamping action and also operates bypass device on the U1079, U1129 & U1797. CONNECTOR KITS: Stud type units are supplied with 3⁄8"-16 hex head nuts with Belleville washers. Order two connector kits to cover both line and load. Order K1539 (single #350), K1540 (single #600) or K1350 (twin #350). See accessories page. NOTE: The U1129 unit has a single connector on the line side only. FIFTH TERMINAL: For field mounted fifth terminal, order as extra K3866 for the U1079 & U1431. Order as extra K3865 for units U1129, U1432, U1819, and U1797. LUG SIZE RANGE: See accessories page for lug size range for the U1129 & U1797 units. Utility requirements for this equipment may vary. Always consult the serving utility for their requirements before ordering or installing equipment in this catalog. B10 320 AMP—4 & 7 TERMINAL—SINGLE POSITION–RINGLESS / RING TYPE—600 VAC 2 1 4 3 5056 3 5 2120 2594 4 6 METER SOCKETS 3 SECTION B 1 B11 5 U2120-X U3548-X 1 2 1 3 4 3548 4 6 5 U5056-O 320 AMP—4 TERMINAL—LINK BYPASS—RING TYPE—1∅3W CONNECTORS SERVICE CATALOG NUMBER CU/AL HUB LINE OH/ UG U3548-X* C.P. UG U5056-O** BLANK LOAD W" H" 1 2 3 4 5 6 LINK 6 14 33 3 3 3 3 1 ⁄4 1 1 4, 2 LINK 6 24 32 3 — 4 1 1 4, 2 ⁄ ⁄ 1 ⁄4 — #4-600 or twin 1/0-250 ⁄2"-13 STUDS CONCENTRIC K.O.ʼS D" SINGLE = 4-600 PARALLEL = 1/0-250 1 DIMENSIONS BYPASS ⁄ ⁄ SEALING RING: Ring type units are supplied with an MR-4, screw type, sealing ring as standard. TRIPLE TAP LUG: For triple tap lug kit order K5049. LINK BYPASS: Links provided by utility. *FLUSH MOUNT KIT: For field mounted flush mount kit order K4086. **This is a PP&L approved unit. 320 AMP—7 TERMINAL—SIDE WIREWAY—RINGLESS AMP 320 320 SERVICE UG OH/UG CATALOG NUMBER U2120-X U2594-X HUB CONNECTORS CU/AL C.P. 3 C.P. 3 ⁄8"-16 STUDS ⁄8"-16 STUDS BYPASS LEVER LEVER DIMENSIONS D" 1 6 H" 3 3 19 1 ⁄2 17 ⁄4 31 ⁄4 1 6 W" CONCENTRIC K.O.ʼS ⁄2 34 ⁄8 1 4 — 2 3 3 3 4 4 4 4 4 5 6 1 ⁄4 1 ⁄4 1 1 ⁄2,3⁄4,1 BYPASS: Lever supplies clamping action on meter spades and operates bypass device. CONNECTOR KITS: Stud type units are supplied with 3⁄8"-16 hex head nuts with Belleville washers. Order two connector kits to cover both line and load. For single lug connector kits for the U2120 and U2594 units, order as extra K3082 (350 kcmil) or K3441 (600 kcmil). For twin lug connectors order as extra: K3442 (350 kcmil). Separate kits are required for both line and load. Utility requirements for this equipment may vary. Always consult the serving utility for their requirements before ordering or installing equipment in this catalog. B11 100-125 AMP—4 TERMINAL—HORIZONTAL GANGS–RINGLESS / RING TYPE—300 VAC METER SOCKETS SECTION B B12 U3522-XL U8032-XL 7 6 1 1 1 4 5 7 3 7 4 5 1 2 7 6 8032 4 3 5 5 1 2 4 3522 100 AMP / POSITION—CONTINUOUS—4 TERMINAL—RINGLESS NO. OF SERVICE POS. 2 3 4 5 6 OH/UG OH/UG OH/UG OH/UG OH/UG CATALOG NUMBER HUB U8032-XL U8033-XL U8034-XL U8035-XL U8036-XL CONNECTORS CU/AL LINE C.P. C.P. C.P. C.P. C.P. #2-350 #2-350 #2-350 #2-350 #2-350 DIMENSIONS LOAD D" #6-2/0 1 1 1 3 1 7 1 1 1 1 #6-2/0 #6-2/0 #6-2/0 #6-2/0 4 4 4 4 4 W" ⁄2 24 ⁄2 ⁄2 32 ⁄4 ⁄2 40 ⁄8 H" 1 2 3 4 5 6 16 2 2 21⁄2 2 1 ⁄2 1 1 4, 2 ⁄ ⁄ 5 1 ⁄2 1 1 4, 2 ⁄ ⁄ 5 ⁄2 1 1 4, 2 ⁄ ⁄ 5 ⁄2 1 1 4, 2 ⁄ ⁄ 5 ⁄2 1 1 4, 2 ⁄ ⁄ 5 16 2 2 2 ⁄2 (3) 2 1 16 2 2 21⁄2 (4) 2 1 2 2 1 2 ⁄2 (5) 2 1 2 2 21⁄2 (6) 2 1 ⁄2 49 ⁄16 16 ⁄2 57 ⁄4 CONCENTRIC K.O.ʼS 16 7 ⁄16 ⁄16 ⁄16 ⁄16 ⁄16 125 AMP / POSITION—CONTINUOUS—4 TERMINAL—RING TYPE NO. OF SERVICE POS. 2 OH/UG CATALOG NUMBER HUB U3522-XL-K1 C.P. CONNECTORS CU/AL DIMENSIONS LINE LOAD D" #2-350 #6-2/0 4 W" H" 1 2 3 4 5 6 ⁄2 241⁄2 14 11⁄2 11⁄2 21⁄2 21⁄2 1 1 4, 2 ⁄ ⁄ 14 11⁄2 11⁄2 21⁄2 (3)21⁄2 1⁄4,1⁄2 14 11⁄2 11⁄2 21⁄2 (4)21⁄2 1⁄4,1⁄2 ⁄2 491⁄16 16 11⁄2 11⁄2 21⁄2 (5)21⁄2 1⁄4,1⁄2 — — — — 1 1 3 OH/UG U3523-XL-K1 C.P. #2-350 #6-2/0 4 4 OH/UG U3524-XL-K2 C.P. #2-350 #6-2/0 4 5 UG U3525-XL-K2* C.P. #2-350 #6-2/0 4 CONCENTRIC K.O.ʼS 3 ⁄2 32 ⁄4 1 ⁄2 407⁄8 1 *FOR OVERHEAD SERVICE: The U3525 is factory configured for underground service. If overhead service is desired, an extension kit is required. Order separately, catalog number K3937. FIFTH TERMINAL: For field mounted fifth terminal, order catalog number 5T8K2 (6 oʼclock only on 100 amp units, 9 oʼclock only on 125 amp units.) HUBS: For proper hub selection, see the hub suffix chart in accessories page. SEALING RINGS: Ring type units are supplied with one MR-4 screw type sealing ring per position. MAIN BUS RATING: See general engineering page. Utility requirements for this equipment may vary. Always consult the serving utility for their requirements before ordering or installing equipment in this catalog. B12 200 AMP—4 TERMINAL—HORIZONTAL GANGS–RINGLESS / RING TYPE—300 VAC B13 SECTION B METER SOCKETS U1252-X-K1 1 1 3 4 5 2 6 3 4 1 1 1 1252 3532 3 4 2 6 3 5 1 4 4 1 1253-6 3533-6 3 200 AMP / POSITION—4 TERMINAL—RINGLESS NO. OF SERVICE POS. 2 3 4 5 6 OH/UG OH/UG UG UG UG CATALOG NUMBER U1252-X-K1 U1253-X-K3 U1254-X-K3* U1255-X-K4* U1256-X-K4* HUB CONNECTORS CU/AL LINE C.P. C.P. C.P. #6-350 #4-600 #4-600 DIMENSIONS LOAD D" #2-350 1 1 1 3 1 7 1 7 1 1 #2-350 #2-350 C.P. (2)#2-600 #2-350 C.P. (2)#2-600 #2-350 W" ⁄8 26 ⁄2 5 ⁄8 34 ⁄4 5 ⁄8 42 ⁄8 5 ⁄8 54 ⁄8 5 H" 1 2 3 14 1 2 ⁄2 3 1 1 14 21⁄2 3 (3)21⁄2 1 16 1 2 ⁄2 3 (4)2 ⁄2 1 16 21⁄2 3 (5)21⁄2 1 3 (6)2 ⁄2 1 ⁄8 63 ⁄16 18 5 CONCENTRIC K.O.ʼS ⁄2 1 2 2 4 ⁄2 1 1 5 6 ⁄4 1 ⁄4 1 ⁄4 1 ⁄4 1 ⁄4 1 ⁄2 1 ⁄2 1 ⁄2 1 ⁄2 1 ⁄2 1 200 AMP / POSITION—4 TERMINAL—RING TYPE NO. OF SERVICE POS. 2 3 OH/UG OH/UG CATALOG NUMBER U3532-X-K1 U3533-X-K3 HUB CONNECTORS CU/AL LINE C.P. C.P. #6-350 #4-600 DIMENSIONS LOAD D" #2-350 1 1 1 3 #2-350 5 5 W" ⁄8 26 ⁄2 ⁄8 34 ⁄4 CONCENTRIC K.O.ʼS H" 1 2 3 4 14 21⁄2 3 21⁄2 14 1 3 (3)2 ⁄2 — — 2 ⁄2 1 5 6 ⁄4 1 ⁄4 1 1 1 *FOR OVERHEAD SERVICE: These units are factory configured for underground service. If overhead service is desired, an extension kit is required. Order as extra, K3923 (4 & 5 position), K3955 (6 position). FIFTH TERMINAL: For field mounted fifth terminal order catalog number K5T to fit into square opening at the 9 oʼclock position. HUBS: For proper hub selection, see the hub suffix chart in accessories page. SEALING RINGS: Ring type units are supplied with one MR-4 screw type sealing ring per position. MAIN BUS RATING: See general engineering page. U1252 & U3532 only rated 400 amp overall. Utility requirements for this equipment may vary. Always consult the serving utility for their requirements before ordering or installing equipment in this catalog. B13 CONDOMINIUM METERING BANKS—RINGLESS CONDOMINIUM METERING BANKS—RINGLESS SECTION B B14 U2854-X-4/125 (Order circuit breakers as extra) U2866-X VERTICAL 125 AMP/POSITION 200 AMP/POSITION NO. OF POS. CATALOG NUMBER MAIN BUS RATING LINE CONNECTOR SIZE NO. OF POS. CATALOG NUMBER MAIN BUS RATING LINE CONNECTOR SIZE 2 U2852-X 200 AMP *3/8"-16 STUD 2 U2862-X 250 AMP *3/8"-16 STUD 3 U2853-X 200 AMP *3/8"-16 STUD 3 U2863-X 300 AMP *3/8"-16 STUD RECTANGULAR 125 AMP/POSITION 200 AMP/POSITION NO. OF POS. CATALOG NUMBER MAIN BUS RATING LINE CONNECTOR SIZE NO. OF POS. CATALOG NUMBER MAIN BUS RATING LINE CONNECTOR SIZE 4 U2854-X 400 AMP *3/8"-16 STUD 4 U2864-X 400 AMP *3/8"-16 STUD 5 U2855-X 400 AMP *3/8"-16 STUD 5 U2865-X 600 AMP *3/8"-16 STUD 6 U2856-X 400 AMP *3/8"-16 STUD 6 U2866-X 600 AMP *3/8"-16 STUD CONNECTOR KITS * SIZE SUFFIX KIT COMPATIBLE NUMBER WITH -K1 K1539 -K3 K1540 SINGLE -K2 K1350 -K4 K1541 TWIN U2852-56 U2862-66 U2854-56 U2864-66 U2854-56 U2863-66 U2864-66 WIRE RANGE #6-350 *CONNECTORS: For line wire connector kits, order separately. FIFTH TERMINALS: For field mounted fifth terminal order catalog number K2381. Order one per meter position (9 oʼclock position only). BREAKERS: Units have provision for one double pole main per meter position. Breakers not included. Order as extra Milbank. PLUG-IN BREAKER COMPATIBILITY CHART #4-600 AMPS #6-350 125-200 HQP / BR / WBJ #2-600 ≤ 100 SIEMENS MURRAY / CROUSE-HINDS G.E. SQ-D — MD THQ — QP MP THQ HOMELINE CUTLER-HAMMER SIEMENS (WESTINGHOUSE) (ITE) QP / BR / HQP Utility requirements for this equipment may vary. Always consult the serving utility for their requirements before ordering or installing equipment in this catalog. B14 CONDOMINIUM METERING BANKS B15 VERTICAL 125 amp/pos. (2-3 position) D 200 amp/pos. (2-3 position) D SECTION B 125 &200 amp/pos. (single position) D 21" C B A 25" or 37" C 13" or 18" 29" or 41" 5 13/16" 5 13/16" E E E B C 18" E E E U2852-X B C 5 13/16" 21" CONDOMINIUM METERING BANKS RECTANGULAR 125 amp/pos. (4,5 & 6 position) 200 amp/pos. (4,5 & 6 position) D FIG. DIMENSIONS A 11⁄4" CONCENTRIC K.O. B 1 D 37" or 25" 29" or 41" ⁄4,1⁄2" CONCENTRIC K.O. C 3" CONCENTRIC K.O. D 4" HUB OPENING E 2" CONCENTRIC K.O. A A A B C 31" A A A 4 7/8" E E E B C E E E 4 7/8" 36" Utility requirements for this equipment may vary. Always consult the serving utility for their requirements before ordering or installing equipment in this catalog. B15 CONDOMINIUM METERING BANKS A NOTES SECTION B B16 NOTES B16 200 AMP—4 & 7 TERMINAL—METER MAIN—RING TYPE—240 VOLT SECTION C 1 2 3584 3587 3 4 4 3 METER MAINS AND SERVICE ENTRANCE EQUIPMENT 2 1 4 5 3574 3577 U3574-RL-200 200 AMP—4 & 7 TERMINAL—RING TYPE NO. OF SERVICE TERMS 4 7 4 7 OH OH UG UG CATALOG NUMBER BREAKER U3574-RL-200 200A-2P U3577-RL-200 U3584-O-200 U3587-O-200 200A-3P 200A-2P 200A-3P CONNECTORS CU/AL DIMENSIONS CONCENTRIC K.O.ʼS LINE LOAD D" W" H" 1 2 3 #2-350 #3-300 4 1 8 30 2 2 21⁄2 1 10 34 2 2 21⁄2 1 #2-350 #6-350 #6-350 #3-300 #3-300 #3-300 ⁄8 7 4 ⁄8 1 1 1 1 5 5 ⁄2 14 ⁄8 ⁄2 14 ⁄8 4 5 6 ⁄4 1 1 4, 2 ⁄ ⁄ ⁄4 1 1 4, 2 ⁄ ⁄ — — — — — — 26 3 3 3 1 1 4, 2 26 3 3 3 1 1 4, 2 ⁄ ⁄ ⁄ ⁄ BREAKERS: Units are supplied with bolt-on 200 amp circuit breakers where specified above. SEALING RINGS: Units are supplied with an MR-4 screw type sealing ring. Utility requirements for this equipment may vary. Always consult the serving utility for their requirements before ordering or installing equipment in this catalog. C1 C1 100/150/200 AMP–RING TYPE / RINGLESS METER MAINS–4 & 5 TERMINAL–22K AIC SECTION C C2 1 3 5 6 1 4 2 5 5 6 5 6 METER MAINS AND SERVICE ENTRANCE EQUIPMENT U5168-XTL-200 5168 5169 5268 5269 U5268-XTL-200-KK 100/150/200 AMP–4 & 5 TERMINAL–METER MAIN–22K AIC–120/240 VOLT–1∅3W–RINGLESS / RING TYPE OVERHEAD / UNDERGROUND–8 & 20 CIRCUIT INTERIOR NO. OF TERMS AMP CIRCUITS 4 4 4 4 4 4 5 5 4 4 4 4 4 4 4 4 100 150 200 100 150 200 100 150 100 150 200 150 200 150 200 200 10 8 8 10 8 8 10 8 10 8 8 20 20 20 20 20 CATALOG NUMBER U5168-XTL-100 ** U5168-XTL-150 ** U5168-XTL-200 ** U5168-XTL-100-KK ** U5168-XTL-150-KK ** U5168-XTL-200-KK ** CONNECTORS HUB LINE C.P. C.P. C.P. C.P. C.P. C.P. U5168-XTL-100-KK-5T ** C.P. U5168-XTL-150-KK-5T ** C.P. U5169-XTL-100 U5169-XTL-150 U5169-XTL-200 U5268-XTL-150 ** U5268-XTL-200 ** U5268-XTL-150-KK ** U5268-XTL-200-KK ** U5269-XTL-200 C.P. C.P. C.P. C.P. C.P. C.P. C.P. C.P. #6-350 #6-350 #6-350 #6-350 #6-350 #6-350 #6-350 #6-350 #6-350 #6-350 #6-350 #6-350 #6-350 #6-350 #6-350 #6-350 DIMENSIONS BYPASS D" W" H" NONE NONE NONE HORN HORN HORN HORN HORN NONE NONE NONE NONE NONE HORN HORN NONE 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 ⁄2 14 ⁄8 32 ⁄2 14 ⁄8 32 ⁄2 14 ⁄8 32 ⁄2 14 ⁄8 32 ⁄2 14 ⁄8 32 ⁄2 14 ⁄8 32 ⁄2 14 ⁄8 32 ⁄2 14 ⁄8 32 ⁄2 14 ⁄8 32 ⁄2 14 ⁄8 32 ⁄2 14 ⁄8 32 ⁄2 14 ⁄8 32 ⁄2 14 ⁄8 32 ⁄2 14 ⁄8 32 ⁄2 14 ⁄8 32 ⁄2 14 ⁄8 32 CONCENTRIC K.O.ʼS 1 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 3 4 3 1 1 3 ⁄2, ⁄4, 1 1 2 3 4 1 1 3 ⁄2, ⁄4, 1 1 2 3 4 1 1 3 ⁄2, ⁄4, 1 1 2 3 4 1 1 3 ⁄2, ⁄4, 1 1 2 3 4 1 1 3 ⁄2, ⁄4, 1 1 2 3 4 1 1 3 ⁄2, ⁄4, 1 1 2 3 4 1 1 3 ⁄2, ⁄4, 1 1 2 3 4 1 1 3 ⁄2, ⁄4, 1 1 2 3 4 1 1 3 ⁄2, ⁄4, 1 1 2 3 4 1 1 3 ⁄2, ⁄4, 1 1 2 3 4 1 1 3 ⁄2, ⁄4, 1 1 2 3 4 1 1 3 ⁄2, ⁄4, 1 1 2 3 4 1 1 3 ⁄2, ⁄4, 1 1 2 3 4 1 1 3 ⁄2, ⁄4, 1 1 2 3 4 1 1 3 ⁄2, ⁄4, 1 1 2 3 4 1 1 3 ⁄2, ⁄4, 1 1 2 3 4 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 ⁄2 ⁄2 ⁄2 ⁄2 ⁄2 ⁄2 ⁄2 ⁄2 ⁄2 ⁄2 ⁄2 ⁄2 ⁄2 ⁄2 ⁄2 ⁄2 5 6 ⁄,⁄ ⁄,⁄ ⁄,⁄ ⁄,⁄ ⁄,⁄ ⁄,⁄ ⁄,⁄ ⁄,⁄ ⁄,⁄ ⁄,⁄ ⁄,⁄ ⁄,⁄ ⁄,⁄ ⁄,⁄ ⁄,⁄ ⁄,⁄ HUB: Supplied with (2) closing plates packed inside. Order hubs as a separate item. See accessory page for hub options. INTERIOR: U5168 units have 8-circuit interior; U5268 units have 20-circuit interior. FIFTH TERMINAL: Order K5T and field install for 208Y/120 network systems. Installs in the 9 oʼclock position only. BREAKERS: Rated 22K AIC with Milbank QNR2200H main installed. INTERLOCK KIT: For generator auxiliary circuit breaker interlock, order K5815 for large QN with small frame Q; order K5820 for large frame QN with large frame QN. SUB-FEED LUGS: #6-350 kcmil sub-feed lugs provided on 8 and 10 circuit interior. Not available on 20 circuit interior. *Amperage rating limited to main breaker rating. Interior has 10 branch circuit breaker provisions. **RINGLESS Utility requirements for this equipment may vary. Always consult the serving utility for their requirements before ordering or installing equipment in this catalog. C2 200 AMP—4 TERMINAL—SERVICE ENTRANCE MAIN BREAKER—UNMETERED—120/240 VAC C3 26" SECTION C 8" 1 2 4 4 USE-AP N A B N A B USE-AP-200-ML G G USE-AP-200-ML USE-AP-200-MB 200 AMP—4 TERMINAL—BREAKER ENCLOSURE—1∅3W, 120/240V—10K AIC RATING NO. OF TERM. 4 4 SERVICE OH OH CATALOG NUMBER USE-AP-200-MB USE-AP-200-ML CONNECTORS DIMENSIONS CONCENTRIC K.O.ʼS HUB LINE 2" #4-250 2" #4-250 D" 5 5 W" 8 8 H" 26 26 1 1 1 2 3 4 2 1 3 2, 4 ⁄ ⁄ 1 3 2, 4 2 1 3 2, 4 1 3 2, 4 ⁄ ⁄ ⁄ ⁄ ⁄ ⁄ NOTE: The neutral bus / ground bar is factory installed. USE-AP-200-MB: 200 Amp main wired in series with plug-in style bus. UQFP-M-200 factory installed Additional 4 branch circuits available for (1) two-pole and (2) one-pole, or (4) one pole breakers. One 2" hub included. USE-AP-200-ML: 200 Amp breaker wired in parallel with plug-in style bus. UQFP-200 factory installed. Additional 4 branch circuits available for (1) two-pole and (2) one-pole, or (4) one pole breakers. One 2" hub included. Utility requirements for this equipment may vary. Always consult the serving utility for their requirements before ordering or installing equipment in this catalog. C3 METER MAINS AND SERVICE ENTRANCE EQUIPMENT 5" 3 400 AMP—320 AMP CONTINUOUS METER MAIN WITH SPLIT LOAD—120/240 VAC METER MAINS AND SERVICE ENTRANCE EQUIPMENT SECTION C C4 1 3 4 5059 5759 1 4 2 5 M400-PAR-UG 5 U4031-O-2/200 U5059-X-2/200 1 3 4 1 2 1 5 M400-PAR 3 4 3 5 2 1 5 4031 4 4 TERMINAL—1∅3W—RINGLESS / 22K AIC SERV. CATALOG NUMBER PRIMARY DISCONNECT OH M400-PAR 200 Amp / 2 Pole Circuit Breaker 200 Amp / 2 Pole Circuit Breaker 200 Amp / 2 Pole Circuit Breaker 200 Amp / 2 Pole Circuit Breaker 200 Amp / 2 Pole Circuit Breaker UG M400-PAR-UG** UG U4031-O-2/200 OH/UG U5059-X-2/200 OH/UG U5759-X-2/200* DIMENSIONS SECONDARY BYDISCONNECT PASS D" W" H" See note See note LEVER LEVER 1 6 ⁄8 1 6 1 9 1 200 Amp / 2 Pole LEVER 5 ⁄4 Circuit Breaker 7 200 Amp / 2 Pole LEVER 4 ⁄8 Circuit Breaker 7 200 Amp / 2 Pole NONE 4 ⁄8 Circuit Breaker 1 2 ⁄2 47 ⁄8 2 2 1 1 1 ⁄8 22 ⁄8 36 3 CONCENTRIC K.O.ʼS 25 15 15 30 42 42 2 ⁄2 3 3 3 2 ⁄2 3 3 3 3 2 4 4 3 3 4 5 1 1 3 2, 4 1 1 3 2, 4 ⁄2 1 ⁄2 2 ⁄ ⁄ ⁄ ⁄ 3 1 1 4, 2 1 1 1 4, 2 1 1 1 4, 2 ⁄4 ⁄4 ⁄ ⁄ ⁄ ⁄ ⁄ ⁄ NEUTRAL: Bonded neutral and ground factory Installed. FLUSH MOUNT: Flush mounting available on underground units. Order catalog number FK-M400-UG separately. SHORT CIRCUIT CURRENT WITHSTAND RATING: 22K AIC Standard. BYPASS: Lever supplies clamping action and operates bypass device. FIFTH TERMINAL: For field installed fifth terminal for the U5059 & U5759, order separately catalog number K3866. CONVERSION KIT: To field convert M400 UG units to OH, order K4787-R. Includes connectors (#2-600). 200 amp primary disconnect factory installed. Order secondary disconnect separately. Specify UQFPH-100, 125, 150, 175 or 200. OVERHEAD: Includes one 3" hub. Provided with connectors for #4-600 or twin 1/0-250. LINE SIDE CONNECTOR KITS: Two 1/2" studs per phase on 1 3/4" centers. Factory installed for the U5759, for the U5059 order anti-rotation connector kit K1540L to accommodate #4-600 kcmil single or K1350L for twin 350 kcmil connectors. *Lever supplies clamping action only–does NOT operate bypass on the U5759. **LUG KIT: Mechanical lug kit available for M400-APS-UG, order K4920 (#2-500). Utility requirements for this equipment may vary. Always consult the serving utility for their requirements before ordering or installing equipment in this catalog. C4 400 AMP—320 AMP CONTINUOUS METER MAIN WITH SPLIT LOAD—120/240 VAC C5 SECTION C 3 2 1 4 METER MAINS AND SERVICE ENTRANCE EQUIPMENT 1 5 5 M400-APS-BS 4 TERMINAL—1∅3W—TYPE 3R—RING TYPE —120/240 VAC SERV OH OH CATALOG NUMBER M400-APS M400-APS-BS DIMENSIONS PRIMARY SECONDARY BYDISCONNECT DISCONNECT PASS D" W" H" 200 Amp / 2 Pole Circuit Breaker 200 Amp / 2 Pole Circuit Breaker See note See note NONE LINK 1 6 ⁄8 6 1 9 11 1 ⁄2 47 ⁄8 1 ⁄2 47 CONCENTRIC K.O.ʼS 1 2 2 1- 2 3 2 1 2 1 ⁄2 2- 2 ⁄2 3-3 4 5 1 1 3 2, 4 4-3 1 1 ⁄2 ⁄ ⁄ 5 ⁄2 6 — 3 ⁄4 EUSERC: Meets EUSERC requirements. Consult local utility for acceptability before ordering or installing. NEUTRAL: Bonded neutral and ground factory Installed. LINE SIDE CONNECTORS: Connectors provided for 4-600 or twin 1/0-250. OVERHEAD: Overhead units include one 3" hub. 200 amp primary disconnect factory installed. Order secondary disconnect separately. Specify UQFPH-100, 125, 150, 175 or 200. Utility requirements for this equipment may vary. Always consult the serving utility for their requirements before ordering or installing equipment in this catalog. C5 400 AMP—320 AMP CONTINUOUS METER MAIN WITH SPLIT LOAD—120/240 VAC METER MAINS AND SERVICE ENTRANCE EQUIPMENT SECTION C C6 1 3 4 1 4 2 5 FIG. 1 5 1 1 2 4 4 FIG. 2 M400-UG-APS-LC U3251-O-200-CB (see next page for dwg. & chart) 3 5 4 TERMINAL—1∅3W–TYPE 3R—RING TYPE PLUG-IN SOCKETS—120/240 VAC SERV UG UG UG UG UG UG CATALOG NUMBER DIMENSIONS PRIMARY SECONDARY BYDISCONNECT DISCONNECT PASS D" W" H" 200 Amp / 2 Pole See note Circuit Breaker 200 Amp / 2 Pole M400-UG-APS-F-BS Circuit Breaker See note 200 Amp 200 Amp M400-UG-APS-P 2 Pole—T-Fuse 2 Pole—T-Fuse 200 Amp / 2 Pole 200 Amp / 2 Pole M400-UG-APS-LC Circuit Breaker Circuit Breaker 200 Amp / 2 Pole 200 Amp / 2 Pole M400-UG-APS-LC-BS Circuit Breaker Circuit Breaker Amp / 2 Pole 200 Amp / 2 Pole U3251-O-200-CB 200 Circuit Breaker Circuit Breaker M400-UG-APS-F NONE LINK NONE 1 6 ⁄8 221⁄8 36 6 29 41 7 ⁄16 1 6 ⁄8 221⁄8 36 NONE 6 29 41 7 LINK 6 29 41 7 24 1 LINK 3 6 ⁄4 ⁄16 40 ⁄16 ⁄4 CONCENTRIC K.O.ʼS 1 1 2 ⁄2 2 1 2 1 2 1 2 1 2 ⁄2 ⁄2 1 2 1 2 1 ⁄2 ⁄2 3 ⁄2 1 1 1 ⁄2 ⁄2 1 ⁄2 1 ⁄2 3 3 4 4 4 4 4 4 FIG. 4 5 1 1 3 2, 4 ⁄ ⁄ 1 ⁄4 1 — 1 1 3 2, 4 ⁄ ⁄ 1 1 — ⁄4 1 — 3 1 3 2, 4 2 ⁄2 2 3 ⁄2 2 3 ⁄4 3 ⁄ ⁄ EUSERC: Meets EUSERC requirements. Consult local utility for acceptability before ordering or installing. NEUTRAL: Bonded neutral and ground factory Installed. LINE SIDE CONNECTORS: Two 1/2" studs per phase on 1 3/4" centers. LOAD SIDE CONNECTORS: 1/0-300 FLUSH MOUNT: Flush mount kit included with M400-UG-APS-F, M400-UG-APS-BS, M400-UG-APS-LC and M400-UG-APS-LC-BS. Available for other underground units. Order catalog number FK-M400-UG separately. SHORT CIRCUIT CURRENT WITHSTAND RATING: 22K AIC standard, 200K AIC standard on T-fuse models. LUG KIT: Mechanical lug kit available, order K4920 (#2-500). CONVERSION KIT: To field convert M400 UG units to OH, order K4787-R. Includes connectors (#2-600). 200 amp primary disconnect factory installed. Order secondary disconnect separately. Specify UQFPH-100, 125, 150, 175 or 200. Two 200 amp T-fuse pull-outs factory installed as primary and secondary disconnects. Two 200 amp 2-pole bolt-on UQFBH main breakers factory installed. BREAKERS: Two 200 Amp 2-pole main breakers factory installed, and semi-flush flange kit packed inside meter section. Universal Copper 24 / 40 Circuit interior accepts Challenger, GE, Murrary, Siemens / ITE, and Cutler-Hammer / Westinghouse universal type plug-in branch circuit breakers. Utility requirements for this equipment may vary. Always consult the serving utility for their requirements before ordering or installing equipment in this catalog. C6 400 AMP—320 AMP CONTINUOUS—METER MAIN COMBINATION SECTION C 1 C7 1 2 4 2 (9) 5 (4) 4 METER MAINS AND SERVICE ENTRANCE EQUIPMENT 1 5 4(32) 3 3 2 6 M400-UG-APS-LC M401-UG (see previous page for details) 400 AMP MAIN BREAKER—4 TERMINAL—1∅3W—TYPE 3R—RING TYPE–120/240 VAC SERV. UG UG CATALOG NUMBER MAIN DISCONNECT M401-UG (1) 400 AMP 2 POLE BREAKER (1) 400 AMP 2 POLE BREAKER M401-UG-BS CONNECTORS CU/AL LINE DIMENSIONS BYLOAD PASS D" W" H" STUDS C.B. STUDS C.B. NONE LINK 6 6 24 24 38 38 CONCENTRIC K.O.ʼS 1 2 3 1 1 1 2 ⁄2 1 2 ⁄2 3 ⁄2 1 3 ⁄2 3 ⁄2 1 3 ⁄2 4 5 6 4 1 1 4 1 1 ⁄4 ⁄4 ⁄2 ⁄2 EUSERC: Meets EUSERC requirements. Consult local utility for acceptability before ordering or installing. NEUTRAL: Bonded neutral and ground factory installed. LINE SIDE CONNECTORS: Two 1/2" studs per phase on 1-3/4" centers. LUG KIT: Mechanical lug kit available, order K4920 (#2-500). FLUSH MOUNT: Flush mount kits are NOT available for these units. SHORT CIRCUIT CURRENT WITHSTAND RATING: 22K AIC standard. CB load side (1) or (2) copper conductors 3/0-500, (2) aluminum conductors 4/0-500 or (1) aluminum conductor 250-500. Utility requirements for this equipment may vary. Always consult the serving utility for their requirements before ordering or installing equipment in this catalog. C7 400 AMP—320 AMP CONTINUOUS—METER MAIN COMBINATION METER MAINS AND SERVICE ENTRANCE EQUIPMENT SECTION C C8 5 6 7 1 2 3 4 6 8 CONCENTRIC K.O.ʼS 1= 2= 3= 4= 5= 6= 7= 8= (12) (4) (4) (2) (3) (4) (1) (4) 1/2" K.O. 1/2, 3/4 3/4, 1" 1/2, 3/4, 1, 1 1/4" 3/4, 1, 1 1/4, 1 1/2" 1, 1 1/4, 1 1/2, 2" 3, 3 1/2, 4" 1/4 diameter hole M404-UG-LC 400 AMP MAIN WITH CIRCUIT LOAD CENTER—4 TERMINAL—1∅3W RING TYPE—120/240 VAC SERV. UG UG CATALOG NUMBER PRIMARY DISCONNECT M404-UG-LC* 400 AMP 2 POLE BREAKER 400 AMP 2 POLE BREAKER M404-UG-LC-BS* SECONDARY DISCONNECT N/A N/A DIMENSIONS BYPASS D" W" H" NONE LINK 6 6 34 47 34 47 CONCENTRIC K.O.ʼS 1 7 8 ⁄4 1 ⁄2 2 4 1 ⁄2 1⁄2,3⁄4 1 11⁄4 11⁄2 2 4 1 1 2 1 3 2, 4 ⁄2 ⁄ ⁄ 3 1 4 5 1 1 1 1 6 EUSERC: Meets EUSERC requirements. Consult local utility for acceptability before ordering or installing. NEUTRAL: Bonded neutral and ground factory installed. LINE SIDE CONNECTORS: (2) 1/2" studs per phase on 1-3/4" centers. LUG KIT: Mechanical lug kit available, order K4920 (#2-500). FLUSH MOUNT: Flush mounting available on underground units. Order catalog number FK-M404-UGLC separately. SHORT CIRCUIT CURRENT WITHSTAND RATING: 22K AIC standard. BRANCH BREAKERS: Use Siemens, Cutler-Hammer, GE or Siemens/Murray breakers to maintain 22K rating. * Includes a 30-circuit load center. Utility requirements for this equipment may vary. Always consult the serving utility for their requirements before ordering or installing equipment in this catalog. C8 ⁄4 ⁄4 TEST BLOCK BYPASS—TB SERIES 100/200 AMP—600 VOLT SELF CONTAINED / SOCKET ONLY D1 These UL Listed products are for use in areas requiring Electrical Utility Service Equipment Requirements Committee (EUSERC) compliance. 5 4 4 SECTION D 2 1 1 3 114TB 115TB 117TB 2 1 6 3 4 124TB 125TB 127TB 127TB 114TB 100 AMP—4, 5 & 7 TERMINAL— FOR USE WITH REMOTE MAIN—RING TYPE NO. TYPE OF OF TERM. SERVICE 4 5 7 OH/UG CATALOG NUMBER 114TB* OH/UG 115TB OH/UG 117TB CONNECTORS CU/AL LINE & LOAD #6-1/0 #6-1/0 #6-1/0 TYPE OF SERVICE 1∅3W * 3∅3W 3∅4W DIMENSIONS D" 5 4 ⁄8 5 4 ⁄8 5 4 ⁄8 CONCENTRIC K.O.ʼS W" H" 1 2 3 4 5 6 12 25 2 2 11⁄2 2 1 ⁄2 1 — — — 12 25 2 2 1 ⁄2 2 1 ⁄2 12 25 2 2 11⁄2 2 1 ⁄2 200 AMP—4, 5 & 7 TERMINAL—FOR USE WITH REMOTE MAIN—RING TYPE NO. TYPE OF OF TERM. SERVICE CATALOG NUMBER CONNECTORS CU/AL LINE & LOAD TYPE OF SERVICE D" W" H" 1 2 3 4 DIMENSIONS CONCENTRIC K.O.ʼS 5 6 ⁄32 1 ⁄32 1 ⁄32 1 4 OH/UG 124TB* #1/0-250 1∅3W * 6 14 30 21⁄2 21⁄2 3 3 9 5 OH/UG 125TB #1/0-250 3∅3W 6 14 30 21⁄2 21⁄2 3 3 9 30 1 3 9 7 OH/UG 127TB #1/0-250 3∅4W 6 14 2 ⁄2 ⁄2 1 2 3 ⁄2 ⁄2 ⁄2 HUBS: OH units use hub up to 21⁄2" (see accessory page). Units provided with closing plates. SEALING RINGS: Units furnished with MR-2 snap style sealing rings. NEUTRAL: “Lay-in” connectors will accommodate #6-2/0 (for 100 amp units) and #2-250 (for 200 amp units) copper or aluminum wire. RING PROTECTOR: Add suffix -RP to catalog number for factory installed ring protector (ex. 117TB becomes 117TB-RP). * For 3W (208Y/120) network service, install field mounted fifth terminal catalog number 105J. See accessories page. SHORT CIRCUIT CURRENT WITHSTAND RATING UP TO 200K AIC DEPENDING ON OVERCURRENT PROTECTION DEVICE USED Utility requirements for this equipment may vary. Always consult the serving utility for their requirements before ordering or installing equipment in this catalog. D1 COMMERCIAL METERING–SAFETY SOCKETS, METER MAINS, TERMINATION BOXES, BUSSED GUTTERS 5 4 D2 TEST BLOCK BYPASS—MTB SERIES—100 AMP—10K AIC 240 VOLT SELF CONTAINED METER MAIN / CIRCUIT BREAKERS COMMERCIAL METERING–SAFETY SOCKETS, METER MAINS, TERMINATION BOXES, BUSSED GUTTERS SECTION D These UL Listed products are for use in areas requiring Electrical Utility Service Equipment Requirements Committee (EUSERC) compliance. 1 5 5 4 3 4 6 2 U214MTB U215MTB U217MTB U214MTB 217MTB 2 1 5 6 3 4 4 214MTB 215MTB 217MTB 100 AMP—4, 5, & 7 TERMINAL—240 VOLT—BREAKER INSTALLED—RING TYPE NO. TYPE OF OF TERM. SERVICE CATALOG NUMBER CONNECTORS LINE TYPE LOAD OF NEUTRAL SERVICE DIMENSIONS D" 5 4 OH 214MTB* #6-2/0 #14-1/0 1∅3W * 4 5 OH 215MTB #6-2/0 #14-1/0 4 3∅3W 7 OH 217MTB #6-2/0 #14-1/0 4 OH/UG U214MTB* #6-2/0 #14-1/0 1∅3W * 3∅4W ⁄8 5 ⁄8 5 4 ⁄8 5 4 ⁄8 5 5 OH/UG U215MTB #6-2/0 #14-1/0 3∅3W 4 7 OH/UG U217MTB #6-2/0 #14-1/0 3∅4W 4 ⁄8 5 ⁄8 W" H" CONCENTRIC K.O.ʼS 1 2 3 4 1 5 6 ⁄32 1 ⁄32 1 12 34 2 2 2 1 ⁄2 9 12 34 2 2 2 11⁄2 9 1 ⁄2 9 ⁄32 1 2 3 2 2 2 12 34 2 2 2 18 25 2 2 21⁄2 1 1 ⁄4 18 25 2 2 2 ⁄2 2 3 18 25 2 2 21⁄2 2 3 ⁄4 ⁄4 ⁄2 ⁄2 ⁄2 REPLACEMENT MAIN DISCONNECTS: For replacement main disconnect see pages D14 & D15. HUBS: OH units use hub up to 21⁄2" (see accessory page). Units provided with closing plate. SEALING RINGS: Units furnished with MR-2 snap style sealing rings. NEUTRAL: “Lay-in” connectors will accommodate #6-2/0 (for 100 amp units) and #2-250 (for 200 amp units) copper or aluminum wire. * For 3W (208Y/120) network service, install field mounted fifth terminal catalog number 105J. See accessories page. Utility requirements for this equipment may vary. Always consult the serving utility for their requirements before ordering or installing equipment in this catalog. D2 TEST BLOCK BYPASS—MTB SERIES—100 AMP—22K AIC 240 VOLT—SELF CONTAINED METER MAIN / CIRCUIT BREAKER D3 These UL Listed products are for use in areas requiring Electrical Utility Service Equipment Requirements Committee (EUSERC) compliance. 5 6 3 4 SECTION D 2 1 4 214MTB/22 217MTB/22 217MTB/22 1 2 6 U214MTB/22 U217MTB/22 5 5 4 3 4 100 AMP—4 & 7 TERMINAL—240 VOLT—BREAKER INSTALLED—RING TYPE NO. TYPE OF OF TERM. SERVICE 4 7 4 7 OH OH CATALOG NUMBER 214MTB/22* 217MTB/22 OH/UG U214MTB/22* OH/UG U217MTB/22 CONNECTORS TYPE DIMENSIONS LINE LOAD OF NEUTRAL SERVICE D" #6-2/0 #14-1/0 1∅3W * 4 #6-2/0 #6-2/0 #6-2/0 #14-1/0 3∅4W #14-1/0 1∅3W * #14-1/0 3∅4W 5 ⁄8 5 4 ⁄8 5 4 ⁄8 5 4 ⁄8 CONCENTRIC K.O.ʼS W" H" 1 2 3 4 5 6 12 34 2 2 2 11⁄2 9 ⁄32 1 12 34 2 2 2 11⁄2 9 ⁄32 1 1 2 2 18 25 2 2 2 ⁄2 2 3 18 25 2 2 21⁄2 2 3 ⁄4 ⁄4 ⁄2 ⁄2 REPLACEMENT MAIN DISCONNECTS: For replacement main disconnect see pages D14 & D15. * For 3W (208Y/120) network service, install field mounted fifth terminal catalog number 105J. See accessories page. HUBS: OH units use hub up to 21⁄2" (see accessory page). Units provided with closing plate. SEALING RINGS: Units furnished with MR-2 snap style sealing rings. NEUTRAL: “Lay-in” connectors will accommodate #6-2/0 (for 100 amp units) and #2-250 (for 200 amp units) copper or aluminum wire. Utility requirements for this equipment may vary. Always consult the serving utility for their requirements before ordering or installing equipment in this catalog. D3 COMMERCIAL METERING—SAFETY SOCKETS, METER MAINS, TERMINATION BOXES, BUSSED GUTTERS U214MTB/22 D4 TEST BLOCK BYPASS—MTB SERIES—100 AMP—14K AIC 480 VOLT—SELF CONTAINED METER MAIN / CIRCUIT BREAKER These UL Listed products are for use in areas requiring Electrical Utility Service Equipment Requirements Committee (EUSERC) compliance. 2 1 5 6 3 4 COMMERCIAL METERING–SAFETY SOCKETS, METER MAINS, TERMINATION BOXES, BUSSED GUTTERS SECTION D 4 214MTB-48 215MTB-48 217MTB-48 1 2 U214MTB-48 U215MTB-48 U217MTB-48 5 5 4 3 4 6 U214MTB-48 217MTB-48 100 AMP—4, 5 & 7 TERMINAL—480 VOLT—BREAKER INSTALLED—RING TYPE NO. TYPE OF OF TERM. SERVICE CATALOG NUMBER CONNECTORS LINE LOAD NEUTRAL TYPE OF SERVICE D" W" H" 1 2 3 4 DIMENSIONS CONCENTRIC K.O.ʼS 5 6 ⁄32 1 ⁄32 1 ⁄32 1 ⁄4 2 ⁄4 2 ⁄4 2 4 OH 214MTB-48* #6-250 #14-1/0 1∅3W 6 14 48 21⁄2 21⁄2 3 3 9 5 OH 215MTB-48 #6-250 #14-1/0 3∅3W 6 14 48 21⁄2 21⁄2 3 3 9 7 OH 217MTB-48 #6-250 #14-1/0 3∅4W 6 14 48 21⁄2 21⁄2 3 3 9 #6-250 #14-1/0 1∅3W 18 25 2 2 21⁄2 2 3 18 25 2 2 21⁄2 2 3 18 25 2 2 21⁄2 2 3 4 OH/UG U214MTB-48* 5 4 ⁄8 5 5 OH/UG U215MTB-48 #6-250 #14-1/0 3∅3W 4 7 OH/UG U217MTB-48 #6-250 #14-1/0 3∅4W 4 ⁄8 5 ⁄8 ⁄2 ⁄2 ⁄2 REPLACEMENT MAIN DISCONNECTS: For replacement main disconnect see pages D14 & D15. HUBS: OH units use hub up to 21⁄2" (see accessory page.) Units provided with closing plate. SEALING RINGS: Units furnished with MR-2 snap style sealing rings. NEUTRAL: “Lay-in” connectors will accommodate #6-2/0 aluminum wire. * For 3W (208Y/120) network service, install field mounted fifth terminal catalog number 105J. See accessory page. Utility requirements for this equipment may vary. Always consult the serving utility for their requirements before ordering or installing equipment in this catalog. D4 TEST BLOCK BYPASS—MTB-P & MTB-P48 SERIES—100 AMP—200K AIC 240 & 480 VOLT—SELF CONTAINED METER MAIN / T-FUSE PULLOUT D5 These UL Listed products are for use in areas requiring Electrical Utility Service Equipment Requirements Committee (EUSERC) compliance. 200K Short Circuit Current Withstand Rating 2 1 4 6 3 4 1 214MTB-P 215MTB-P 217MTB-P 214MTB-P48 215MTB-P48 217MTB-P48 2 U214MTB-P U215MTB-P U217MTB-P U214MTB-P48 U215MTB-P48 U217MTB-P48 5 5 4 3 4 6 214MTB-P SECTION D 5 U217MTB-P NO. TYPE OF OF TERM. SERVICE CATALOG NUMBER CONNECTORS LINE LOAD NEUTRAL TYPE OF SERVICE DIMENSIONS D" W" CONCENTRIC K.O.ʼS H" 1 1 ⁄2 4 OH 214MTB-P* #1/0-250 #14-1/0 1∅3W * 6 14 48 2 5 OH 215MTB-P #1/0-250 #14-1/0 6 14 48 21⁄2 14 48 1 18 25 7 4 5 7 OH OH/UG OH/UG OH/UG 217MTB-P U214MTB-P* U215MTB-P U217MTB-P #1/0-250 #14-1/0 #6-2/0 #6-2/0 #6-2/0 3∅3W 3∅4W #14-1/0 1∅3W * #14-1/0 #14-1/0 3∅3W 3∅4W 6 5 4 ⁄8 5 4 ⁄8 5 4 ⁄8 2 ⁄2 2 2 3 4 5 6 ⁄32 1 ⁄32 1 ⁄32 1 ⁄4 2 ⁄4 2 ⁄4 2 1 ⁄2 3 3 9 21⁄2 3 3 9 2 ⁄2 1 3 3 9 2 21⁄2 2 3 1 2 18 25 2 2 2 ⁄2 2 3 18 25 2 2 21⁄2 2 3 ⁄2 ⁄2 ⁄2 100 AMP—4, 5, & 7 TERMINAL—480 VOLT—PULL-OUT INSTALLED—RING TYPE NO. TYPE OF OF TERM. SERVICE CATALOG NUMBER CONNECTORS LINE TYPE OF LOAD NEUTRAL SERVICE D" W" H" 1 2 3 4 DIMENSIONS CONCENTRIC K.O.ʼS 5 6 ⁄32 1 ⁄32 1 ⁄32 1 ⁄4 2 ⁄4 2 ⁄4 2 4 OH 214MTB-P48* #6-250 #14-1/0 1∅3W * 6 14 48 21⁄2 21⁄2 3 3 9 5 OH 215MTB-P48 #6-250 #14-1/0 3∅3W 6 14 48 21⁄2 21⁄2 3 3 9 7 OH 217MTB-P48 #6-250 #14-1/0 3∅4W 6 14 48 21⁄2 21⁄2 3 3 9 5 18 25 2 2 21⁄2 2 3 1 4 5 7 OH/UG OH/UG OH/UG U214MTB-P48* U215MTB-P48 U217MTB-P48 #6-250 #6-250 #6-250 #14-1/0 1∅3W * #14-1/0 #14-1/0 3∅3W 3∅4W 4 ⁄8 5 18 25 2 2 2 ⁄2 2 3 5 18 25 2 2 21⁄2 2 3 4 4 ⁄8 ⁄8 ⁄2 ⁄2 ⁄2 REPLACEMENT MAIN DISCONNECTS: For replacement main disconnect see pages D14 & D15. * For 3W (208Y/120) network service, install field mounted fifth terminal catalog number 105J. See accessory page. HUBS: OH units use hub up to 21⁄2" (see accessory page). Units provided with closing plate. SEALING RINGS: Units furnished with MR-2 snap style sealing rings. NEUTRAL: “Lay-in” connectors will accommodate #6-2/0 aluminum wire. PULL-OUTS: For use with T-fuses only. Fuses are included with fused safety sockets. Utility requirements for this equipment may vary. Always consult the serving utility for their requirements before ordering or installing equipment in this catalog. D5 COMMERCIAL METERING–SAFETY SOCKETS, METER MAINS, TERMINATION BOXES, BUSSED GUTTERS 100 AMP—4, 5, & 7 TERMINAL—240 VOLT—PULL-OUT INSTALLED—RING TYPE D6 TEST BLOCK BYPASS—MTB SERIES—200 AMP—10K AIC 240 VOLT—SELF CONTAINED METER MAIN / CIRCUIT BREAKER SECTION D These UL Listed products are for use in areas requiring Electrical Utility Service Equipment Requirements Committee (EUSERC) compliance. COMMERCIAL METERING–SAFETY SOCKETS, METER MAINS, TERMINATION BOXES, BUSSED GUTTERS 5 4 6 3 1 2 1 4 224MTB 225MTB 227MTB 5 5 4 4 3 6 2 U224MTB U225MTB U227MTB U227MTB 224MTB 200 AMP—4, 5 & 7 TERMINAL—240 VOLT—BREAKER INSTALLED—RING TYPE NO. TYPE OF OF TERM. SERVICE 4 OH CATALOG NUMBER 224MTB* CONNECTORS LINE #6-250 LOAD NEUTRAL TYPE OF SERVICE #2/0-250 1∅3W * DIMENSIONS CONCENTRIC K.O.ʼS D" W" H" 1 2 3 4 6 14 48 21⁄2 21⁄2 3 3 9 1 ⁄2 5 6 ⁄32 1 ⁄32 1 ⁄32 1 1 ⁄2 3 3 9 21⁄2 3 3 9 1 ⁄2 3 1 2 ⁄2 3 5 OH 225MTB #6-250 #2/0-250 3∅3W 6 14 48 2 7 OH 227MTB #6-250 #2/0-250 3∅4W 6 14 48 21⁄2 30 1 2 30 21⁄2 21⁄2 3 21⁄2 3 30 21⁄2 21⁄2 3 21⁄2 3 4 OH/UG U224MTB* #6-250 #2/0-250 1∅3W * 6 22 3 ⁄4 5 OH/UG U225MTB #6-250 #2/0-250 3∅3W 6 22 3 7 OH/UG U227MTB #6-250 #2/0-250 3∅4W 6 22 3 ⁄4 ⁄4 ⁄2 2 2 ⁄2 ⁄2 ⁄2 ⁄4 2 ⁄2 ⁄4 21⁄2 ⁄4 21⁄2 1 REPLACEMENT MAIN DISCONNECTS: For replacement main disconnect see pages D14 & D15. HUBS: OH units use hub up to 21⁄2" (see accessory page). Units provided with closing plate. SEALING RINGS: Units furnished with MR-2 snap stye sealing rings. NEUTRAL: “Lay-in” connectors will accommodate #2-250 copper or aluminum wire. *For 3W (208Y/120) network service, install field mounted fifth terminal catalog number 105J. See accessory page. Utility requirements for this equipment may vary. Always consult the serving utility for their requirements before ordering or installing equipment in this catalog. D6 TEST BLOCK BYPASS—MTB SERIES—200 AMP—22K AIC 240 VOLT—SELF CONTAINED METER MAIN / CIRCUIT BREAKER D7 These UL Listed products are for use in areas requiring Electrical Utility Service Equipment Requirements Committee (EUSERC) compliance. 4 224MTB/22 227MTB/22 5 5 4 4 3 6 2 U224MTB/22 U227MTB/22 U227MTB/22 224MTB/22 200 AMP—4 & 7 TERMINAL—240 VOLT—BREAKER INSTALLED—RING TYPE NO. TYPE OF OF TERM. SERVICE CATALOG NUMBER CONNECTORS LINE LOAD NEUTRAL TYPE OF SERVICE DIMENSIONS D" W" CONCENTRIC K.O.ʼS H" 1 1 ⁄2 4 OH 224MTB/22* #6-250 #2/0-250 1∅3W * 6 14 48 2 7 OH 227MTB/22 #6-250 #2/0-250 6 14 48 21⁄2 30 1 2 30 21⁄2 4 7 OH/UG U224MTB/22* OH/UG U227MTB/22 #6-250 #6-250 3∅4W #2/0-250 1∅3W * #2/0-250 3∅4W 6 6 22 3 22 3 ⁄4 ⁄4 ⁄2 2 3 4 5 6 ⁄32 1 ⁄32 1 1 ⁄2 3 3 9 21⁄2 3 3 9 1 ⁄2 3 1 2 ⁄2 3 21⁄2 3 21⁄2 3 2 2 ⁄2 ⁄2 ⁄4 2 ⁄2 ⁄4 21⁄2 1 REPLACEMENT MAIN DISCONNECTS: For replacement main disconnect see pages D14 & D15. HUBS: OH units use hub up to 21⁄2" (see accessory page). Units provided with closing plate. SEALING RINGS: Units furnished with MR-2 snap stye sealing rings. NEUTRAL: “Lay-in” connectors will accommodate #2-250 copper or aluminum wire. *For 3W (208Y/120) network service, install field mounted fifth terminal catalog number 105J. See accessory page. Utility requirements for this equipment may vary. Always consult the serving utility for their requirements before ordering or installing equipment in this catalog. D7 COMMERCIAL METERING–SAFETY SOCKETS, METER MAINS, TERMINATION BOXES, BUSSED GUTTERS 6 3 SECTION D 5 4 1 2 1 D8 TEST BLOCK BYPASS—MTB SERIES—200 AMP—35K AIC 480 VOLT—SELF CONTAINED METER MAIN / CIRCUIT BREAKER These UL Listed products are for use in areas requiring Electrical Utility Service Equipment Requirements Committee (EUSERC) compliance. COMMERCIAL METERING–SAFETY SOCKETS, METER MAINS, TERMINATION BOXES, BUSSED GUTTERS SECTION D 35K Short Circuit Current Withstand Rating 2 1 5 4 6 3 4 224MTB-48 227MTB-48 1 2 U227MTB-48 227MTB-48 5 5 4 3 4 6 U224MTB-48 U227MTB-48 200 AMP—4 & 7 TERMINAL—480 VOLT—BREAKER INSTALLED—RING TYPE NO. TYPE OF OF TERM. SERVICE 7 OH CATALOG NUMBER 227MTB-48 CONNECTORS LINE #6-250 LOAD NEUTRAL #2/0-250 TYPE OF SERVICE 3∅4W DIMENSIONS D" 6 W" 14 4 OH/UG U224MTB-48* #6-250 #2/0-250 1∅3W * 6 22 3 7 OH/UG #6-250 #2/0-250 6 22 3 U227MTB-48 3∅4W ⁄4 ⁄4 CONCENTRIC K.O.ʼS H" 1 48 1 2 30 30 ⁄2 2 3 4 5 6 ⁄32 1 1 ⁄2 3 3 9 21⁄2 21⁄2 3 21⁄2 3 21⁄2 21⁄2 3 21⁄2 3 2 ⁄2 ⁄4 21⁄2 ⁄4 21⁄2 REPLACEMENT MAIN DISCONNECTS: For replacement main disconnect see pages D14 & D15. HUBS: OH units use hub up to 21⁄2" (see accessory page). Units provided with closing plate. SEALING RINGS: Units furnished with MR-2 snap style sealing rings. NEUTRAL: “Lay-in” connectors will accommodate #2-250 copper or aluminum wire. * For 3W (208Y/120) network service, install field mounted fifth terminal catalog number 105J. See accessory page. Utility requirements for this equipment may vary. Always consult the serving utility for their requirements before ordering or installing equipment in this catalog. D8 TEST BLOCK BYPASS—MTB-P SERIES & MTB-P48 SERIES—200 AMP—200K AIC 240/480 VOLT—SELF-CONTAINED METER MAIN / T-FUSE PULLOUT D9 These UL Listed products are for use in areas requiring Electrical Utility Service Equipment Requirements Committee (EUSERC) compliance. 200K Short Circuit Current Withstand Rating 5 4 1 6 3 2 5 5 4 4 224MTB-P 225MTB-P 227MTB-P 224MTB-P48 225MTB-P48 227MTB-P48 4 3 6 U224MTB-P U227MTB-P U224MTB-P48 U227MTB-P48 U227MTB-P 200 AMP—4, 5 & 7 TERMINAL—240 VOLT PULLOUT INSTALLED—RING TYPE NO. TYPE OF OF TERM. SERVICE CATALOG NUMBER CONNECTORS LINE TYPE OF LOAD NEUTRAL SERVICE DIMENSIONS CONCENTRIC K.O.ʼS D" W" H" 1 2 3 4 5 6 ⁄32 1 ⁄32 1 ⁄32 1 ⁄4 2 ⁄4 2 4 OH 224MTB-P* #6-250 #1/0-250 1∅3W * 6 14 48 21⁄2 21⁄2 3 3 9 5 OH 225MTB-P #6-250 #1/0-250 3∅3W 6 14 48 21⁄2 21⁄2 3 3 9 7 OH 227MTB-P #6-250 #1/0-250 3∅4W 6 14 48 21⁄2 21⁄2 3 3 9 4 OH/UG U224MTB-P* 30 2 2 21⁄2 2 3 30 2 2 21⁄2 2 3 7 OH/UG U227MTB-P #6-250 #1/0-250 1∅3W * #6-250 #1/0-250 3∅4W 6 6 22 3 22 3 ⁄4 ⁄4 ⁄2 ⁄2 ⁄2 200 AMP—4, 5 & 7 TERMINAL—200 AMP-480 VOLT PULLOUT INSTALLED —RING TYPE NO. TYPE OF OF TERM. SERVICE CATALOG NUMBER CONNECTORS LINE TYPE OF LOAD NEUTRAL SERVICE DIMENSIONS CONCENTRIC K.O.ʼS D" W" H" 1 2 3 4 5 6 ⁄32 1 ⁄32 1 ⁄32 1 ⁄4 2 ⁄4 2 4 OH 224MTB-P48* #6-250 #1/0-250 1∅3W * 6 14 48 21⁄2 21⁄2 3 3 9 5 OH 225MTB-P48 #6-250 #1/0-250 3∅3W 6 14 48 21⁄2 21⁄2 3 3 9 7 OH 227MTB-P48 #6-250 #1/0-250 3∅4W 6 14 48 21⁄2 21⁄2 3 3 9 30 2 2 21⁄2 2 3 30 2 2 21⁄2 2 3 4 OH/UG U224MTB-P48* #6-250 #1/0-250 1∅3W * 6 22 3 7 OH/UG #6-250 #1/0-250 6 22 3 U227MTB-P48 3∅4W ⁄4 ⁄4 ⁄2 ⁄2 ⁄2 REPLACEMENT MAIN DISCONNECTS: For replacement main disconnect see pages D14 & D15. HUBS: OH units use hub up to 21⁄2" (see accessory page). Units provided with closing plate. SEALING RINGS: Units furnished with MR-2 snap style sealing rings. NEUTRAL: “Lay-in” connectors will accommodate #2-250 copper or aluminum wire. PULL-OUTS: For use with T-fuses only. Fuses are included with fused safety sockets. * For 3W (208Y/120) network service, install field mounted fifth terminal catalog number 105J. See accessory page. Utility requirements for this equipment may vary. Always consult the serving utility for their requirements before ordering or installing equipment in this catalog. D9 COMMERCIAL METERING–SAFETY SOCKETS, METER MAINS, TERMINATION BOXES, BUSSED GUTTERS 224MTB-P SECTION D 2 1 D10 TEST BLOCK BYPASS—MTBL ALL-IN-ONE SERIES—100 & 200 AMP—10K & 200K AIC 240 VOLT METER MAIN—CIRCUIT BREAKER / T-FUSE PULLOUT These UL Listed products are for use in areas requiring Electrical Utility Service Equipment Requirements Committee (EUSERC) compliance. 25" or 27" ON OFF COMMERCIAL METERING–SAFETY SOCKETS, METER MAINS, TERMINATION BOXES, BUSSED GUTTERS SECTION D 24 3/4" or 30" 4 5/8" or 6" U227-MTBL CATALOG NUMBER U214MTBL RATING NO. MAIN CIRCUIT BREAKER INTERNAL OR CIRCUITS 100A,120/240 12/24 VAC 1∅3W 100A,120/240 12/24 U214MTBPL VAC 1∅3W U217MTBL U217MTBPL U224MTBL 100A, 240Δ/120; 208Y/120 VAC 3∅4W 100A, 240Δ/120; 208Y/120 VAC 3∅4W U227MTBPL D" W" 100A, 2P, 10K Milbank Q2100 45⁄8 25 243⁄4 100A, 2P, 100K Boltswitch PT223 45⁄8 UTILITY SECTION (1) 1/2" (3) 11/4",11/2",2",21/2" 25 243⁄4 100A, 3P, 10K Siemens BQ3100 45⁄8 25 243⁄4 18/36 100A, 3P, 100K Boltswitch PT323 45⁄8 25 243⁄4 200A, 2P, 10K Milbank UQFP-200 6 27 30 200A, 2P, 100K Boltswitch PT224 6 200A,120/240 20/40 U224MTBPL VAC 1∅3W U227MTBL FUSE PULLOUT BOTTOM BACK CONDUIT K.O.ʼS CONDUIT K.O.ʼS H" 18/36 200A,120/240 20/40 VAC 1∅3W 200A, 240Δ/120; 208Y/120 VAC 3∅4W 200A, 240Δ/120; 208Y/120 VAC 3∅4W DIMENSIONS 24/42 24/42 CUSTOMER SECTION (3) 1/2", 3/4" (1) 1/2" ,3/4" ,1",11/4" (2) 3/4",1",11/4",11/2" CUSTOMER SECTION (7) 1/2" (4) 1/2" , 3/4" 3 (1) /4" ,1",11/4",11/2" UTILITY SECTION 200A, 3P, 10K Siemens QJ23B200 6 200A, 3P, 100K Boltswitch PT324 6 27 27 27 30 30 30 (1) 1/2", 3/4" (2) 11/4",11/2", 2",21/2" (1) 21/2" ,3" CUSTOMER SECTION (11) 1/2" (2) 1/2", 3/4" (1) 1/2" ,3/4",1",11/4" (2) 3/4",1",11/4",11/2" CUSTOMER SECTION (6) 1/2" (4) 1/2" , 3/4" 3 (1) /4" ,1",11/4",11/2" LINE: Underground or overhead service. Line Lug: 100A, 14-2/0 and 200A 1/0-250 LOAD: Underground only. BRANCH BREAKERS: Single phase units—approved for Siemens/ITE Type Q, Challenger, Cutler-Hammer/Westinghouse, General Electric, Murray. Three phase units—approved for Siemens/ITE Type Q. HUBS: OH units use hub up to 21⁄2" (see accessory page). Units provided with closing plate. PULL-OUTS: For use with T-fuses only. Fuses are included with fused safety sockets. For 208Y/120 applications, order separately and field install kit 105J. Utility requirements for this equipment may vary. Always consult the serving utility for their requirements before ordering or installing equipment in this catalog. D10 UNDERGROUND TERMINATION BOXES—600 VAC D11 These UL Listed products are for use in areas requiring Electrical Utility Service Equipment Requirements Committee (EUSERC) compliance. SECTION D PB-011 PB-032 PB-012 PB-038 X- dim. PB-011 1 1/4" 1 1/4" 1 1/4" 1 1/4" PB-012 PB-032 UNDERGROUND TERMINATION BOXES AMPS TYPE CATALOG OF NUMBER SERVICE LINE LOAD D" W" H" X" SHORT CIRCUIT CURRENT WITHSTAND RATING CONNECTORS DIMENSIONS 100 1∅-3W PB-011 #14-1/0 #14-1/0 4 12 81⁄2 33⁄4 10K AMPS 200 1∅-3W PB-012 #6-250 #6-250 6 12 26 141⁄4 10K AMPS 400 1∅-3W 1/2"-13 studs twin 1⁄0-250 6 16 36 22 50K AMPS 800 1∅-3W PB-014 PB-014-NK PB-018 PB-018-NK 1/2"-13 studs twin 1⁄0-250 11 24 48 26 50K AMPS 200 3∅-4W PB-032 #6-250 #6-250 6 16 26 1411⁄16 10K AMPS 400 3∅-4W PB-034 PB-034-NK 1/2"-13 studs twin 1⁄0-250 6 16 36 22 50K AMPS 800 3∅-4W PB-038 1/2"-13 studs twin 1⁄0-250 11 24 48 26 50K AMPS * #4-600 #4-600 #4-600 #4-600 CONNECTORS AND BUSSING: Extruded aluminum connectors and bus bars are tin plated. For no knockouts, add suffix -NK to the above catalog numbers. No lift handles provided on the PB-011. 2 studs per lug position provided for 400 amp units. 4 studs per lug position provided for 800 amp units. Utility requirements for this equipment may vary. Always consult the serving utility for their requirements before ordering or installing equipment in this catalog. D11 COMMERCIAL METERING–SAFETY SOCKETS, METER MAINS, TERMINATION BOXES, BUSSED GUTTERS X-dim. X-dim. D12 BUSSED GUTTERS—TYPE 3R—1∅3W AND 3∅4W—600 VAC COMMERCIAL METERING–SAFETY SOCKETS, METER MAINS, TERMINATION BOXES, BUSSED GUTTERS SECTION D These UL Listed products are for use in areas requiring Electrical Utility Service Equipment Requirements Committee (EUSERC) compliance. BC418 FOR COMMERCIAL SAFETY SOCKET APPLICATIONS 1∅3W—BUSSED GUTTERS—TYPE 3R—600 VAC DIMENSIONS METER POSITION CATALOG NUMBER AMPERE RATING D" 2 BC214 400 6 3 BC318 800 6 4 BC418 800 5 BC518 6 BC618 W" H" LENGTH OF BUS LINE LUGS PER EACH BUS LOAD LUGS PER EACH BUS 20" Bar (1) 600 (2) 6-250 28 ⁄8 151⁄2 5 151⁄2 (2) 20" Bars (2) 600 (3) 6-250 6 57 ⁄4 15 ⁄2 (2) 20" Bars (2) 600 (4) 6-250 800 6 715⁄8 151⁄2 (2) 20" Bars (2) 600 (5) 6-250 800 6 85 ⁄8 15 ⁄2 (2) 20" Bars (2) 600 (6) 6-250 LENGTH OF BUS LINE LUGS PER EACH BUS LOAD LUGS PER EACH BUS 20" Bar (1) 600 (2) 6-250 43 1 7 1 1 3∅4W—BUSSED GUTTERS—TYPE 3R—600 VAC DIMENSIONS METER POSITION CATALOG NUMBER AMPERE RATING D" 2 BC234 400 6 3 BC338 800 6 4 BC438 800 5 BC538 6 BC638 W" H" 285⁄8 151⁄2 15 ⁄2 (2) 20" Bars (2) 600 (3) 6-250 6 571⁄4 151⁄2 (2) 20" Bars (2) 600 (4) 6-250 800 6 71 ⁄8 15 ⁄2 (2) 20" Bars (2) 600 (5) 6-250 800 6 857⁄8 151⁄2 (2) 20" Bars (2) 600 (6) 6-250 43 5 1 1 SHORT CIRCUIT CURRENT WITHSTAND RATING: Standard bracing is 42K AIC. CONNECTORS AND BUSSING: Extruded aluminum connectors and bus bars are tin plated. COVER: Lift handles provided along with a cover sealing provision. A removable, sealable cover is provided at both ends for pull box assembly. HARDWARE: Meter socket mounting hardware included. SUITABLE FOR USE ON LINE SIDE OF SERVICE EQUIPMENT. Utility requirements for this equipment may vary. Always consult the serving utility for their requirements before ordering or installing equipment in this catalog. D12 BUSSED GUTTERS—TYPE 3R—3∅4W—600 VAC D13 These UL Listed products are for use in areas requiring Electrical Utility Service Equipment Requirements Committee (EUSERC) compliance. • • • • 3∅4W—BUSSED GUTTERS—TYPE 3R—600 VAC LINE LUGS PER EACH BUS 24 24 17" Bar (1) 600 6 36 24 24" Bars (2) 600 800 6 48 24 32" Bars (3) 600 U3465-O 800 6 60 24 40" Bars (3) 600 U3466-O 800 6 72 24 56" Bars (3) 600 CATALOG NUMBER AMPERE RATING D" W" 2 U3462-O 400 6 3 U3463-O 600 4 U3464-O 5 6 SHORT CIRCUIT CURRENT WITHSTAND RATING: The 400 and 600 amp units have a withstand rating of 50K amps, and the 800 amp units have a rating of 65K amps. SUITABLE FOR USE ON LINE SIDE OF SERVICE EQUIPMENT. Gasket attached to Pull Box Bussed Gutter Knockouts Pull Box Meter Socket Typical Application of Safety Sockets with Multi-Metering (shown with KOs) Utility requirements for this equipment may vary. Always consult the serving utility for their requirements before ordering or installing equipment in this catalog. D13 COMMERCIAL METERING–SAFETY SOCKETS, METER MAINS, TERMINATION BOXES, BUSSED GUTTERS H" LENGTH OF BUS DIMENSIONS METER POSITION SECTION D Enclosure without knockouts Tin plated aluminum bus bars Furnished with line lugs only Bus is drilled and tapped for easy installation of load lugs D14 SAFETY SOCKET REPLACEMENT CIRCUIT BREAKERS & PULLOUTS COMMERCIAL METERING–SAFETY SOCKETS, METER MAINS, TERMINATION BOXES, BUSSED GUTTERS SECTION D REPLACEMENT CIRCUIT BREAKERS REPLACEMENT CIRCUIT BREAKERS, cont. CATALOG NUMBER CIRCUIT BREAKER MFG. PART NUMBER CATALOG NUMBER CIRCUIT BREAKER MFG. PART NUMBER 214MTB BQ2B100L Milbank 917930-MO 227MTB UQFB-3200 Milbank 916777-MO 214MTB-48 ED42B100 Siemens 705831-MO 227MTB-125 UQFB-3125 Milbank 916759-MO 214MTB/22 BQ2B100HL Milbank 917960-MO 227MTB-150 UQFB-3150 Milbank 916765-MO U214MTB BQ2B100L Milbank 917930-MO 227MTB-175 UQFB-3175 Milbank 926772-MO U214MTB-48 ED42B100 Siemens 705831-MO 227MTB-48 FXD63B200 Siemens 706036-MO U214MTB/22 BQ2B100HL Milbank 917960-MO 227MTB/22 QJH23B200L Siemens 707503-MO U214MTBL BQ2B100L Milbank 917915-MO 227MTB UQFB-3200 Milbank 916777-MO U227MTB-125 UQFB-3125 Milbank 916759-MO 215MTB BQ3B100L Milbank 917990-MO U227MTB-150 UQFB-3150 Milbank 916765-MO 215MTB-48 ED43B100 Siemens 708571-MO U227MTB-175 UQFB-3175 Milbank 926772-MO U215MTB BQ3B100L Milbank 917990-MO U227MTB-48 FXD63B200 Siemens 706036-MO U215MTB-48 ED43B100 Siemens 708571-MO U227MTB/22 QJH23B200L Siemens 707503-MO U227MTBL QJ23B200 Siemens 707403-MO 217MTB BQ3B100L Milbank 917990-MO 217MTB-48 ED43B100 Siemens 708571-MO 217MTB/22 BQ3B100HL Milbank 918020-MO U217MTB BQ3B100L Milbank 917990-MO U217MTB-48 ED43B100 Siemens 708571-MO U217MTB/22 BQ3B100HL Milbank 918020-MO U217MTBL BQ3B100L Milbank 917990-MO SIEMENS CIRCUIT BREAKER NUMBER OF LUG COLLARS REQUIRED PART NUMBER 224MTB UQFB-200 Milbank 915548-MO ED42B100 (2) LN13100 705831-MO 224MTB/22 UQFBH-200 Milbank 915748-MO ED43B100 (3) LN1E100 708572-AC U224MTB UQFB-200 Milbank 915548-MO FXD62B200 (4) TA1FD350 708573-AC U224MTB-48 FXD62B200 Siemens 705747-MO FXD63B200 (6) TA1FD350 706036-MO U224MTB/22 UQFBH-200 Milbank 915748-MO QJ22B200H (2) TA1Q300 707523-MO U224MTBL UQFB-200 Milbank 915548-MO QJ23B200 (1) TA1Q300 707403-MO QJH23B200L (1) TA1Q300 707503-MO U225MTB UQFB-3200 Milbank 916777-MO U225MTBL QJ23B200 Siemens 707403-MO LUG KITS FOR CIRCUIT BREAKERS When replacing Siemens Circuit Breaker (FXD,ED,QJ) in safety sockets, lug collars must be ordered separately. D14 SAFETY SOCKET REPLACEMENT CIRCUIT BREAKERS & PULLOUTS D15 REPLACEMENT T-FUSE PULLOUTS LUG KITS FOR T-FUSE PULLOUTS MFG. PART NUMBER T-FUSE PULLOUTS NUMBER OF LUG COLLARS REQUIRED PART NUMBER 214MTB-P PT223 Boltswitch 707674-MO PT223 (2) TK100P 707682-AC 214MTB-P48 PT263 Boltswitch 708564-MO PT224 (2) TK200P 708570-AC U214MTB-P PT223 Boltswitch 707674-MO PT263 (2) TK100P 707682-AC U214MTB-P48 PT263 Boltswitch 708564-MO PT264 (2) TK200P 708570-AC U214MTBPL PT223 Boltswitch 707674-MO PT323 (3) TK100P 707682-AC 215MTB-P PT323 Boltswitch 708565-MO PT324 (3) TK200P 708570-AC 215MTB-P48 PT363 Boltswitch 708566-MO PT363 (3) TK100P 707682-AC U215MTB-P PT323 Boltswitch 708565-MO PT364 (3) TK200P 708570-AC U215MTB-P48 PT363 Boltswitch 708566-MO 217MTB-P PT323 Boltswitch 708565-MO 217MTB-P48 PT363 Boltswitch 708566-MO U217MTB-P PT323 Boltswitch 708565-MO U217MTB-P48 PT363 Boltswitch 708566-MO U217MTBPL PT323 Boltswitch 708565-MO 224MTB-P PT224 Boltswitch 707684-MO 224MTB-P48 PT264 Boltswitch 708567-MO U224MTB-P PT224 Boltswitch 707684-MO U224MTB-P48 PT264 Boltswitch 708567-MO U224MTBPL PT224 Boltswitch 707684-MO 225MTB-P48 PT364 Boltswitch 708569-MO U225MTBPL PT324 Boltswitch 708568-MO 227MTB-P PT324 Boltswitch 708568-MO 227MTB-P48 PT364 Boltswitch 708569-MO U227MTB-P PT324 Boltswitch 708568-MO U227MTB-P48 PT364 Boltswitch 708569-MO U227MTBPL PT324 Boltswitch 708568-MO D15 NOTE: T-Fuse pullouts provided with load side lugs. Order line side lugs separately from above chart. COMMERCIAL METERING–SAFETY SOCKETS, METER MAINS, TERMINATION BOXES, BUSSED GUTTERS T-FUSE PULLOUT SECTION D CATALOG NUMBER D16 SAFETY SOCKET & T-FUSE REPLACEMENT PARTS COMMERCIAL METERING–SAFETY SOCKETS, METER MAINS, TERMINATION BOXES, BUSSED GUTTERS SECTION D These UL Listed products are for use in areas requiring Electrical Utility Service Equipment Requirements Committee (EUSERC) compliance. TB200-47 MS-27-TB TENANT METER SOCKETS REPLACEMENT TEST BLOCKS AMPS CATALOG NUMBER VOLTAGE / SYSTEM AMPS CATALOG NUMBER PHASE 200 MS-24-TB 600V / 1∅3W 100 TB100-47 PHASE A, B & C 200 MS-27-TB 600V / 3∅4W 100 TB100-5 CENTER BLOCK ONLY PHASE B—3∅3W 200 TB200-47 PHASE A, B & C 200 TB200-5 CENTER BLOCK ONLY PHASE B—3∅3W 200 TB200-LL LUG—LUG — TB-BARR #Z707371-MO TEST BLOCK BARRIER PT324 240 VOLT MAIN DISCONNECTS PULLOUT SWITCH (USES TYPE “T” FUSE) 480 VOLT MAIN DISCONNECTS PULLOUT SWITCH (USES TYPE “T” FUSE) AMPS CATALOG NUMBER RATING AMPS CATALOG NUMBER RATING 100 PT223 2 POLE—240 VOLT 100 PT263 2 POLE, 480 VOLT 200 PT224 2 POLE—240 VOLT 200 PT264 2 POLE, 480 VOLT 100 PT323 3 POLE—240 VOLT 100 PT363 3 POLE, 480 VOLT 200 PT324 3 POLE—240 VOLT 200 PT364 3 POLE, 480 VOLT Utility requirements for this equipment may vary. Always consult the serving utility for their requirements before ordering or installing equipment in this catalog. D16 OVERVIEW E1 Commercial Pedestals • Attractive Un-Strut Your Stuff... • Easy to install • Secure • Cost effective Commercial Pedestal UL Listed as Industrial Control Equipment (File E113855). STANDARD FEATURES –COMMERCIAL PEDESTALS Ringless Socket Ring-type Socket Utility Lug Landing Customer Interior • Type 3R rainproof, vandal-resistant cabinet of polyurethane powder-coated steel (aluminum or stainless steel also available) • UL listed as enclosed industrial control equipment (UL508) • Isolated, lockable & sealable utility metering & lug landing sections • Lockable customer section for distribution & control equipment with internal deadfront • Print pocket inside customer section door contains wiring schematics and installation instructions • Most load centers are UL listed for use with various manufacturers’ circuit breakers • All stainless steel external hardware (screws, bolts, hinges, handles, hasps and sealing screws) • Meets EUSERC 308 and other utility standards. Utility requirements for this equipment may vary. Always consult the serving utility for their requirements before ordering or installing equipment in this catalog. E1 COMMERCIAL METER PEDESTALS Strut and backboard design SECTION E ilbank Commercial Pedestals are pad-mounted, weatherproof electrical enclosures consisting of a utility pull section with optional meter socket, and a customer section containing distribution and control equipment. Milbank Commercial Pedestals are an attractive, secure, easy to install and costeffective solution when underground remote site power distribution and control equipment is required, replacing unsightly and inefficient strut and backboard structures. E2 APPLICATIONS & ACCESSORIES APPLICATIONS These units are ideal for controlling and metering: • Traffic signals • Street lighting • Irrigation / sprinkler systems • Cell towers / telephone vaults • Pump stations • Temporary power for fairgrounds, swap meets, outdoor markets, portable offices, holiday lights, etc. • Outdoor lighting for athletic fields, tennis and basketball courts, parking lots, landscaping and subdivision entrances, etc. COMMERCIAL METER PEDESTALS SECTION E AVAILABLE FACTORY-INSTALLED OPTIONS • Meter sockets – ring type or ringless, to 400 amp (unmetered pedestals also available) • Main and branch breakers or T fuses • Distribution – copper load centers & panel boards • Clocks / timers / relays • Photoelectric cells and controls • Power receptacles – pin & sleeve, twist lock or straight blade • Contactors – definite purpose, electrical or mechanically held, IEC and mercury types • Surge protection & lightning arrestors • Reserve inlet generator receptacle with interlocked circuit breakers • Motor starters, relays • Push button controls • Thermostat controls, fans and heating strips • Power blocks and terminal blocks • Steel, aluminum and plywood back boards • Transformers • Interlock devices for circuit breakers • Available in steel, aluminum (raw painted or anodized) or stainless steel construction with powder-coated finish available in 8 standard colors or special ordered RAL colors. • Available for applications up to 400 amp, 120V, 208V, 240V, 277V, 480V – 1Ø or 3Ø. ACCESSORIES 105J Fifth terminal kit for use with ring-type meter sockets CP-TC7D 7-day time clock kit CP-TC24H 24-hour time clock kit CP-TCWIRE Male four-pin connector and wiring harness for use with time clocks other than shown K3865 Fifth terminal kit for use with ringless meter sockets CP-ABK5/8 Anchor bolt kit (includes four 5/8 13 x 18" anchor bolts) CP-16PDMNT-CALT Pedestal mounting base for 16" pedestal CP-24PDMNT-CALT Pedestal mounting base for 24" pedestal (includes mounting hardware) CP-PE-HOA-3POS HOA switch – for field installation Utility requirements for this equipment may vary. Always consult the serving utility for their requirements before ordering or installing equipment in this catalog. E2 CATALOG NUMBER LOGIC E3 SECTION E COMMERCIAL METER PEDESTALS Logic description subject to change and factory interpretation. E3 E4 ML SERIES–MAIN LOAD CENTER CP3B “ML” Series Features: These units include everything required for remote site service: Main Load Center Series 1∅ 3 wire 120/240 or 208Y/120 volt NEMA 3R construction Typical applications: Remote site service for multiple loads Expandable – Load centers allow for future expansion without costly modifications The Milbank Main Load Center Commercial Pedestals are designed to handle the vast majority of all requirements in a standard, stocked configuration. All units feature 200 amp meter socket with optional field-installable fifth terminal kit available • No waiting or extra charge 22K ampere interrupting capacity (AIC) COMMERCIAL METER PEDESTALS SECTION E • Units all feature a load center with a plugon, back-fed main breaker. standard Optional mounting base can be embedded in • Load center has 16 positions for the 100 amp pedestals and 24 circuits for the 200 amp pedestals. concrete for fast, easy installation Separate sealable and lockable utility • Both sizes include sub-feed lugs to allow feeding an external panel termination section Separate sealable and lockable metering If your application requires turning loads on based on “dusk-todawn” requirements, be sure to see the Milbank Switched Load Center Commercial Pedestal products on the following page. section with the option of: EITHER Milbank ring-type socket with test / bypass blocks (conforms to EUSERC 308) OR Milbank heavy duty ringless socket with lever bypass A separate sealable and lockable customer section with a load center for “always on” loads that includes: • Main circuit breaker • Twenty (200 or 125 amp model) or fourteen (100 amp model) blank breaker spaces • A circuit directory to document configuration STOCKED PEDESTALS* OPTIONAL FIFTH TERMINAL KIT MAIN CB LOAD CENTER AMPS SPACES CIRCUITS AIC METER SOCKET TYPE CP3B11115A22 105J 100 1,2 16 22K Ring-type with test / bypass blocks CP3B11115A42 105J 100 1,2 16 42K Ring-type with test / bypass blocks CP3B12119A22 105J 200 1,2,3,4 24 22K Ring-type with test / bypass blocks CP3B51115A22 K3865 100 1,2 16 22K Ringless socket with lever bypass CP3B52119A22 K3865 200 1,2,3,4 24 22K Ringless socket with lever bypass *NOTE: Chart shows standard, stocked items. Other options and features are available. Contact factory for options details and availability. Utility requirements for this equipment may vary. Always consult the serving utility for their requirements before ordering or installing equipment in this catalog. E4 SL SERIES–SWITCHED LOAD CENTER CP3B “SL” Series Features: These units include everything required for remote service: Switched Load Center Series 1∅ 3 wire 120/240 or 208Y/120 volt NEMA 3R construction Expandable – Load centers allow for future expansion Typical applications: Traffic signal, parking lot, highway, & athletic field lighting All units feature 200 amp meter socket with optional The Milbank Switched Load Center Commercial Pedestals are designed to not only provide power for various loads, but also to switch specific loads on and off under certain conditions. A photoelectric cell is used for these controlled loads, and an optional time clock is also available. E5 without costly modifications field-installable fifth terminal kit available 22K ampere interrupting capacity (AIC) standard Optional mounting base can be embedded in concrete for fast, easy installation Separate sealable and lockable utility termination section Separate sealable and lockable metering section with the option of: EITHER Milbank ring-type socket with test / bypass blocks (conforms to EUSERC 308) OR Milbank heavy duty ringless socket with lever bypass A separate sealable and lockable customer section with: Control circuit including: • PE receptacle, Lexan® window and glare shield • Hand-Off-Auto (HOA) switch • Contactor controlling a 16-circuit load center for controlled loads • Pre-mounted DIN rail and pre-wired connector to add an optional “plug and play” time clock kit for PE on and TC off operation • A circuit directory to document configuration A load center for “always on” loads that includes: • Main circuit breaker • Control power circuit breaker • Switched load center main breaker • Nine (200 amp model) or eleven (100 amp model) blank breaker spaces • A circuit directory to document configuration STOCKED PEDESTALS* OPTIONAL FIFTH TERMINAL KIT MAIN CB AMPS SPACES CONTACTOR AMPERAGE METER SOCKET TYPE CP3B11110A22SL1 105J 100 (1,3) 60 Ring-type with test / bypass blocks CP3B12110A22SL1 105J 200 (1,2,3,4) 100 Ring-type with test / bypass blocks CP3B51110A22SL1 K3865 100 (1,3) 60 Ringless socket with lever bypass CP3B52110A22SL1 K3865 200 (1,2,3,4) 100 Ringless socket with lever bypass *NOTE: Chart shows standard, stocked items. Other options and features are available. Contact factory for options details and availability. Utility requirements for this equipment may vary. Always consult the serving utility for their requirements before ordering or installing equipment in this catalog. E5 COMMERCIAL METER PEDESTALS SECTION E E6 400 AMP SERIES Features: CP3B “400” Series These units include everything required for remote site service: 400 amp Series 1∅ 3 wire 120/240 or 208Y/120 volt NEMA 3R construction Main circuit breaker or dual service Typical applications: Remote site service for residential and commercial jobsites disconnects The Milbank 400 amp Commercial Pedestal is designed to provide a weather and vandal resistant metered enclosure for various loads and distribution. Each pedestal has been designed to handle a wide range of applications using standard, stocked configurations. COMMERCIAL METER PEDESTALS SECTION E • Choice of a single main breaker or twin service disconnect breakers gives flexibility to the pedestal design. Expandable – Load center units allow for future expansion without costly modifications 22K ampere interrupting capacity (AIC) standard Optional mounting base can be embedded in concrete for fast, easy installation Separate sealable and lockable utility • Optional distribution with feedthru lugs below the service disconnect breakers allows the pedestal to handle numerous applications. termination section with lug termination Separate sealable and lockable metering section A separate sealable and lockable customer •Typical applications include remote homes where the metering is best located at the curb side or other remote area. The pedestal can also provide power to secondary residence, on-site business, workshop, irrigation, lighting, security or other secondary load. section with a circuit directory and a print pocket to hold all documentation Meter Socket Options: • Ring type with bypass studs • Ringless with heavy duty lever bypass • K type bolt-on • Available in custom c o l o r s t o m a t c h home or landscaping. STOCKED PEDESTALS* OPTIONAL FIFTH TERMINAL KIT CP3B1411JB22 N/A CP3B14120B22 N/A CP3B5411JB22 K3865 MAIN CB 320 amp (400 max) 2-200 amp 320 amp (400 max) LOAD CENTER CIRCUITS AIC 0 22K Ring type with test / bypass studs (2) 12 ckt 22K Ring type with test / bypass studs 0 22K Ringless with lever bypass 22K Ringless with lever bypass METER SOCKET TYPE CP3B54120B22 K3865 2-200 amp (2) 12 ckt CP3B8411JB22 400 amp 0 22K K4 Bolt-on CP3B84120B22 2-200 amp (2) 12 ckt 22K K4 Bolt-on *NOTE: Chart shows standard, stocked items. Other options and features are available. Contact factory for options details and availability. Stud utility landing is standard. Lug kits are available from factory. Units with load centers have (2) #6-250 sub-feed lugs on each load center. (Each load center is 200 amp rated and UL Listed with: Siemens, General Electric and Cutler-Hammer plug-in style circuit breakers.) When ordering, specify lugs or studs for utility landings. Three phase units available — contact factory. Utility requirements for this equipment may vary. Always consult the serving utility for their requirements before ordering or installing equipment in this catalog. E6 IR SERIES–IRRIGATION CONTROL Features: CP3B “IR” Series These units include everything required for remote site service: Irrigation Control Pedestals 1∅ 3 wire 120/240 or 208Y/120 volt NEMA 3R construction Typical application: Metered Power Pedestal for Irrigation Systems 2 each 20 amp single pole circuit breakers: one breaker for standard 20 amp GFCI receptacle and one breaker for irrigation control circuit Large plywood back panel for mounting irrigation controller All units feature 200 amp meter socket with optional field-installable fifth terminal kit available 10K ampere interrupting capacity (AIC) standard Optional mounting base can be embedded in concrete for fast, easy installation termination section Separate sealable and lockable metering section with the option of EITHER: Milbank ring-type socket with test / bypass blocks (conforms to EUSERC 308) OR Milbank heavy duty ringless socket with lever bypass OPTIONAL FIFTH** TERMINAL KIT EXTERIOR CABINET CP3B111IRASP 105J Steel, Light Green Ring type meter socket with test / bypass blocks CP3B111IRASS 105J Stainless Steel Ring type meter socket with test / bypass blocks CP3B511IRASP K3865 Steel, Light Green METER SOCKET TYPE Ringless heavy duty meter socket with lever bypass *NOTE: Chart shows standard, stocked items. Other options and features are available. Contact factory for options details and availability. *See page E2 for options (accessories) details. Utility requirements for this equipment may vary. Always consult the serving utility for their requirements before ordering or installing equipment in this catalog. E7 COMMERCIAL METER PEDESTALS Separate sealable and lockable utility SECTION E The Milbank “IR” series Commercial Pedestals are designed to provide a weather and vandal resistant metered enclosure for irrigation controllers. Breakers and a GFI duplex receptacle are provided to power the irrigation controllers supplied by others. A plywood backboard is mounted behind the deadfront door for mounting the irrigation controller. A large plan pocket is mounted inside t h e customer section door to hold plans and specifications. L i g h t g r e e n powder coated steel or stainless steel pedestals are normally in stock. STOCKED PEDESTALS* E7 E8 BBS/UPS SERIES CP3B BBS & UPS Series 1Ø 3 wire 120/240 or 120/208 volt Typical applications: Metered emergency uninterrupted power for traffic intersections, wireless - phone, communication equipment, parking lots, camera and security locations. The Milbank BBS / UPS Series Commercial Pedestals Industrial Control Equipment” 100 through 320 amp meter socket with the option of either: Milbank ring type socket (conforms to EUSERC 309) with or without test / bypass blocks Milbank heavy duty ringless socket with lever bypass Separate sealable utility termination compartment An isolated separate customer section with: Service disconnects loads, and also to switch specific loads on and off under Power distribution options Power control be used to control lighting circuits as an example. SECTION E NEMA 3R construction, UL listed as “Enclosed are designed to provide continuous power for various certain conditions. A photoelectric cell or time clock may COMMERCIAL METER PEDESTALS Features: Metered and non-metered power distribution options are available. The back-up power pedestal is designed to handle the vast majority of todays back-up power requirements. By using 19” rack design, shelves can be 19” wide rack in customer compartment for easy layout of equipment Battery trays Thermostat with cooling fan Filtered louvers for heat rise flow through ventilation (UL Listed 508A) adjusted to accommodate the required batteries and Three point door latch (key or pad lockable) manufactures DC to AC inverters, transfer switches and Options: other related equipment. This design gives the user a wide range of design and configuration options. Complete turnkey, ready to power-up pedestals are offered along with basic and custom configurations. Manual Bypass switch (used for maintenance of BBS/UPS) Transfer switch for generator power back-up Generator inlet receptacles 30 amps through 200 amps Pad lockable provision for receptacles Police access door Metered load center distribution Non metered load center distribution Photo electric controls (for street lighting) Time clocks HOA switches Contactors GFI duplex receptacles Thermostat for heating control Heating pads or elements Roll out shelves for batteries Surge arrestors and lighting arrestors Utility requirements for this equipment may vary. Always consult the serving utility for their requirements before ordering or installing equipment in this catalog. E8 POWER TRANSFER SERIES–METERED & UNMETERED CP3B “Power Transfer” Series – Metered CP3B “Power Transfer” Series 1Ø3W 120/240 volt thru 3Ø4W 277/480 volt Typical applications: Traffic intersections, Cell sites, Phone company broadband service, Cable TV, Pump and Lift stations requiring utility power with back up generator power E9 The Milbank Commercial Pedestal “Power Transfer Series” provides metered AC power, distribution, surge suppression, mechanical interlock and stand by generator receptacle. All electrical equipment including the generator receptacle is built inside the pedestal, giving it a clean appearance and making it extremely vandal resistant. Features & Options: Features & Options: 120/240v 1∅3W thru 277/480v 3∅4W ratings 60 amps thru 400 amp ratings 10K AIC up to 50K AIC ratings UL listed 508A, NEMA 3R rated Pad lockable, isolated utility compartments 20 amp GFI convenience receptacle Utility and generator indicator light options All stainless steel hardware Galvanized steel, aluminum or stainless steel cabinet options Custom designs available Utility requirements for this equipment may vary. Always consult the serving utility for their requirements before ordering or installing equipment in this catalog. E9 COMMERCIAL METER PEDESTALS CP3B “Power Transfer” Series – Unmetered The Milbank Commercial Pedestal “Power Transfer Series” provides non metered AC power, distribution, surge suppression, mechanical interlock and stand-by generator receptacle – all in a neat, compact pedestal. SECTION E Generator Receptacle Inside! 120/240v 1∅3W thru 277/480v 3∅4W ratings Choice of EUSERC ring type or ringless meter sockets 60 amps thru 400 amp ratings 10K AIC up to 50K AIC ratings UL Listed 508A, NEMA 3R rated Pad lockable, isolated utility compartments 20 amp GFI convenience receptacle Lockable recessed generator receptacle door Utility and generator indicator light options All stainless steel hardware Galvanized steel, aluminum or stainless steel cabinet options Custom designs available E10 GENERAL SPECIFICATIONS Example of specifications for a Metered Commercial Pedestal Commercial pedestal shall be type ______________ . Catalog # _________________ COMMERCIAL METER PEDESTALS SECTION E Voltage rating :____(120/240v 1P 3W)__ AIC rating: ____10__ Amperage rating :____(100 amps)__ The pedestal shall be of NEMA Type 3R rainproof construction and shall be UL Listed as “Enclosed Industrial Control Equipment” (UL 508A). External construction shall comply with UL50 requirements and shall be of G90 galvanized steel with light green #14672 Federal Specification 595 polyurethane industrial grade powder paint of 1.7 mil minimum thickness (unless otherwise specified). Aluminum and stainless steel are other factory options available. Internal construction shall be G90 galvanized steel and 1.7 mil minimum thickness polyurethane industrial grade powder coat painted or bare aluminum. No fasteners except sealing screws shall be removable by external access. Hinges shall be stainless steel and of the continuous piano hinge type. The pedestal mounting bolts shall not be externally accessible. The pedestal shall be offered with an optional base designed to be embedded in concrete in place of anchor bolts. Either pedestal mounting base or anchor bolt kit is required for installation. The customer compartment door to be hinged on the left hand side. A stainless pad-lockable hasp provided to secure customer compartment. A door keeper provided to keep the door in an open position. A print pocket on the inside of the door shall hold all wiring schematics, circuit directories and instructions in a clear, weatherproof sleeve. Required UL labeling shall be located on the inside of the customer door. Distribution and control equipment shall be behind an internal deadfront door with a quarter-turn securing latch and be hinged to open more than 90 degrees. The dead-front door shall be hinged on the same side as the customer section door. All distribution and control equipment shall be factory wired using 600 volt wire sized to NEC and UL requirements. The service pedestal shall be rated for operation at 10K minimum (AIC) amps interrupting capacity. The provided documentation shall list circuit breaker combinations and those to be used for de-rated operation for series ratings. Circuit breakers shall be permanently labeled with engraved name plates. Utility requirements for this equipment vary. Always consult the serving utility for their requirements before ordering or installing this equipment. The service pedestal must have three separate isolated sections for metering equipment, utility termination and customer equipment. The metering section must be pad-lockable and sealable and have a hinged swing back hood with an integral hinged polycarbonate sealable window for access to demand meters. An external nameplate shall be permanently attached to the hood. A stainless steel handle shall be provided on the front exterior of the hood. Meter socket type shall meet the requirements of the serving utility. The utility termination section must be pad-lockable and sealable and shall have a stainless steel handle provided on a lift-off cover. Sufficient clearance shall be provided for a 4-inch diameter conduit for utility cables entrance. Utility landing lugs shall be UL listed and shall accommodate #6 – 350 kcmil conductors. E10 COMMERCIAL METER PEDESTAL DRAWINGS–16" METERED & UNMETERED E11 “A” Style 16" Metered Commercial Pedestal HINGED DEMAND METER RESET COVER WITH WINDOW REMOVEABLE TEST BYPASS BLOCK COVER (IF APPLICABLE) FULLY HINGED METER SECTION COVER 36" MIN. CLEARANCE PER MOUNTING BASE DETAIL REQUIRED N.E.C 110-16 PHOTO CELL WINDOW WITH SHIELD (IF APPLICABLE) PRINT POCKET TYPICAL FRONT & BACK 16" 15" 14 1/2" 13" PADLOCK BRACKET EXTENDS THROUGH DOOR FOR SECURITY 48" 42" UTILITY SECTION 14 1/2" 9 3/4" 16" 12 1/4" LIFT-OFF SERVICE COVER 17" ENCLOSURE DEPTH CUSTOMER SECTION SECTION E 23.5" UTILITY TERMINATION LANDING MIN. HINGED DEADFRONT 6 3/4" ANCHOR BOLT MOUNTING HOLES PEDESTAL MOUNTING HOLES COMMERCIAL METER PEDESTALS 3" RECOMMENDED MIN. FOUNDATION EXTENSION ALL SIDES. 6" REC. HINGED EXTERIOR DOOR WITH DOOR STOP TO HOLD DOOR IN OPEN POSITION CP-16PDMNT-CALT MOUNTING BASE CP-16PDMNT-CALT MOUNTING BASE Pad Mount Base or (4) 5/8-11 X 18” Anchor Bolts Recommended “E” Style 16" Unmetered Commercial Pedestal–Low Profile PHOTO CELL WINDOW WITH SHIELD (IF APPLICABLE) PRINT POCKET MOUNTING BASE DETAIL LIFT-OFF SERVICE COVER LATCH HASP EXTENDS THROUGH DOOR FOR SECURITY 16" 15" 14 1/2" 13" 32 1/4" 40 1/2" 36" MIN. CLEARANCE REQUIRED PER N.E.C 110-16 TYPICAL FRONT & BACK UTILITY SECTION HINGED DEADFRONT 23 7/8" UTILITY TERMINATION LANDING MIN. 16" 14 1/2" 9 3/4" 12 1/4" CUSTOMER SECTION 6 3/4" 17" ENCLOSURE DEPTH ANCHOR BOLT MOUNTING HOLES HINGED EXTERIOR DOOR PEDESTAL MOUNTING HOLES CP-16PDMNT-CALT MOUNTING BASE CP-16PDMNT-CALT MOUNTING BASE 3" RECOMMENDED MIN. FOUNDATION EXTENSION ALL SIDES. 6" REC. MINIMUM DEPTH. Pad Mount Base or (4) 5/8-11 X 18" Anchor Bolts Recommended Utility requirements for this equipment may vary. Always consult the serving utility for their requirements before ordering or installing equipment in this catalog. E11 E12 COMMERCIAL METER PEDESTAL DRAWINGS–24" METERED & UNMETERED “B” Style 24" Metered Commercial Pedestal “B” Style 24" Metered (With one or two meters)Commercial Pedestal HINGED DEMAND METER RESET COVER WITH WINDOW REMOVEABLE TEST BYPASS BLOCK COVER (IF APPLICABLE) FULLY HINGED METER SECTION COVER MOUNTING BASE DETAIL 24" PHOTO CELL WINDOW WITH SHIELD (IF APPLICABLE) PRINT POCKET 36" MIN. CLEARANCE REQUIRED PER N.E.C 110-16 TYPICAL FRONT & BACK 23" 22 1/2" 21" PADLOCK BRACKET EXTENDS THROUGH DOOR FOR SECURITY 48" 42" 14 1/2" 9 3/4" 16" 12 1/4" 23.5" UTILITY TERMINATION LANDING MIN. HINGED DEADFRONT SECTION E COMMERCIAL METER PEDESTALS UTILITY SECTION CP-24PDMNT-CALT MOUNTING BASE 17" ENCLOSURE DEPTH CUSTOMER SECTION ANCHOR BOLT MOUNTING HOLES LIFT-OFF SERVICE COVER HINGED EXTERIOR DOOR WITH DOOR STOP TO HOLD DOOR IN OPEN POSITION 6 3/4" PEDESTAL MOUNTING HOLES 3" RECOMMENDED MIN. FOUNDATION EXTENSION ALL SIDES. 6" REC. MINIMUM DEPTH. CP-24PDMNT-CALT MOUNTING BASE Pad Mount Base or (4) 5/8-11 X 18" Anchor Bolts Recommended “M” Style 24"24" Unmetered Pedestal “M” Style MeteredCommercial Commercial Pedestal PHOTO CELL WINDOW WITH SHIELD (IF APPLICABLE) PRINT POCKET MOUNTING BASE DETAIL 24" 22 1/2" 21 1/2" 21" PADLOCK BRACKET EXTENDS THROUGH DOOR FOR SECURITY CUSTOMER SECTION 15 3/8" 17" 22 1/2" UTILITY TERMINATION LANDING HINGED DEADFRONT 12 1/4" 14 1/4" UTILITY TERM. SECTION 6 1/2" 1 7/8"" 1 1/2"" LIFT-OFF SERVICE COVER CP-24PDMNT-CALT MOUNTING BASE HINGED EXTERIOR DOOR WITH DOOR STOP TO HOLD DOOR IN OPEN POSITION CP-24PDMNT-CALT MOUNTING BASE 3" RECOMMENDED MIN. FOUNDATION EXTENSION ALL SIDES. 6" RECOMMENDED MINIMUM DEPTH. 36" MIN. CLEARANCE REQUIRED PER N.E.C 110-16 TYPICAL FRONT & BACK Pad Mount Base or (4) 5/8-11 X 18" Anchor Bolts Recommended Utility requirements for this equipment may vary. Always consult the serving utility for their requirements before ordering or installing equipment in this catalog. E12 COMMERCIAL METER PEDESTAL DRAWINGS–32" METERED E13 “K” Style 32" Metered Commercial Pedestal (With one or two meters) SECTION E COMMERCIAL METER PEDESTALS (4) 5/8-11 X 18" Anchor Bolts Recommended Catalog Number CP-ABK5/8 Utility requirements for this equipment may vary. Always consult the serving utility for their requirements before ordering or installing equipment in this catalog. E13 E14 COMMERCIAL METER PEDESTAL DRAWINGS–METERED “D” Style Metered Commercial Pedestal VENTILATED OPENINGS W/ SOFFIT LIFTING EYES VENTILATION FAN SLOPED ROOF SECTION 3 SECTION 2 SECTION 4 SECTION 5 19.06 AVAILABLE EQUIPMENT SPACE SECTION 1 PE SOCKET KNOCKOUTS 1/4 TURN PADLOCKABLE HANDLES SECTION 7 VENTILATION LOUVERS WITH FILTER 44.38 24.12 TO BOTTOM OF LUG 60.00 27.31 AVAILABLE EQUIPMENT SPACE 48.56 SECTION E 24.00 “C” Style 54" Metered Commercial Pedestal 24.50 30.50 A PE WINDOW DEMAND METER DOOR DEMAND METER WINDOW 19" RACK METER DOOR METER DOOR PADLOCK-ABLE CAM LATCH METER SECTION CUSTOMER DOOR CUSTOMER DOOR 55.50 SEAL STUD 54.25 PADLOCK-ABLE 3-POINT CAM LATCH 19" RACK REMOVEABLE COVER PLATES FOR INSTALLATION B A B UTILITY PULL SECTION COMMERCIAL METER PEDESTALS SECTION 6 REMOVEABLE UTILITY COVER PADLOCK HASP SEAL STUD SECTION A-A SCALE 1 : 16 REMOVEABLE AIR FILTERS PRINT POCKET 3-POINT CAM LATCH 19" RACK Utility requirements for this equipment may vary. Always consult the serving utility for their requirements before ordering or installing equipment in this catalog. E14 COMMERCIAL METER PEDESTALS WORKSHEET E15 Commercial Pedestal Worksheet Phone (816)483-5314 Fax (816)483-6357 Please answer all of the questions as best as you can. Additional comments as to application and future requirements will help Milbank will determine the best product for your job. Distributor: __________________________ Phone: _________________ Fax: ___________________ Contact Name: _____________________________ Application: ______________________________ Milbank Representative: _______________________________ Salesmen: ______________________ Job Name & Location: _________________________________________________________________ Agency Specifications: (DOT-City-Other) _________________________________________________ Unit Amperage: ___________ Voltage: ____________ Phase: ____________ Wire: _____________ Meter socket (200 Amp) RING-TYPE RINGLESS Fifth Terminal? NO YES (at _____ o’clock) Meter socket (200 Amp) RING-TYPE RINGLESS Fifth Terminal? NO YES (at _____ o’clock) Amp: __________ Poles: __________ KAIC: __________ Main breaker requirements: Amp: __________ Poles: __________ KAIC: __________ Interior #1 0-42 circuits ________ Load center ________ Panel board ________ Metered? YES NO Interior #2 0-42 circuits ________ Load center ________ Panel board ________ Metered? YES NO Amps: Poles: KAIC: Label & Special requirements: Qty _____Breakers ______ ______ ______ __________________________ Qty _____Breakers ______ ______ ______ __________________________ Qty _____Breakers ______ ______ ______ __________________________ Qty _____Breakers ______ ______ ______ __________________________ Qty _____Breakers ______ ______ ______ __________________________ Qty _____Breakers ______ ______ ______ __________________________ Controls: Qty _____ Time Clock: 24 Hr _____ 7 Day _____ 365 Day Astro _____ Description: _______________ Qty _____ Photo Electric Control Receptacle Qty _____ Test switch: 2 Pos. _____ 3 Pos. _____ HOA Type _____ Other ________________________ Qty _____ Control Transformer ___________ Voltage ___________VA Size (required for all 277/480v) Contactors: Type: Lighting - LT / Definite Purpose - DP / Mechanical Held - MH / Mercury - MV / IEC - IC Qty ______ Type ______ Amps ______ Poles ______ Coil voltage ______ Other ________ Qty ______ Type ______ Amps ______ Poles ______ Coil voltage ______ Other ________ Qty ______ Type ______ Amps ______ Poles ______ Coil voltage ______ Other ________ Cabinet / Finish requirements: Alum – Untreated = AO / Alum Anodized = AL / Stainless Steel = SS Aluminum – Painted = A / GALVANIZED STEEL PAINTED MINT GREEN (STANDARD) (STANDARD) _______ (specify paint below) = G / Pine Green = PG / Dark Green = DG / Black = BK / Desert Tan = DT White = W / Gray = P / Summerland Gray = SG / Other (RAL finish number) ____________________ Other Requirements: ___________________________________________________________________ _____________________________________________________________________________________ Please send any drawings, plans, specifications, and load/panel board schedules with worksheet E15 COMMERCIAL METER PEDESTALS Branch breakers: SECTION E Main breaker requirements: NOTES SECTION E E16 NOTES E16 F1 36 or 48 36.00 or 48.00 CURRENT TRANSFORMER CABINETS–TYPE 3R–DOOR MOUNT CT RATED SOCKET 363612-CT3R-SP 364812-CT3R-SP2 SECTION F NO. OF CATALOG TERMS. NUMBER BYPASS CONNECTORS AMPS K4806-BP Plunger #14-4 Max 20 A 13 DIMENSIONS D" W" H" 21⁄2 77⁄8 71⁄2 BP: The -BP suffix indicates plunger bypass. 12184-LC3R CURRENT TRANSFORMER RATED CABINETS—TYPE 3R CATALOG NUMBER 243210-LC3R-SP 323610-LC3R-SP 363016-CT3R 363612-CT3R-SP 364812-CT3R-SP2 D" W" H" GAUGE OF STEEL 10 10 16 12 12 24 32 36 36 36 32 36 30 36 48 14 14 14 14 14 DIMENSIONS PANEL SIZE W" x H" 21 29 33 33 33 29 33 27 33 45 PANEL & BACKBOARD CATALOG NUMBERS PAINTED STEEL PANEL WOOD BACKBOARD A-24P32 A-32P36 A-36P30 A-36P36 A-48P36 A-24P32W A-32P36W A-36P30W A-36P36W INCLUDED A-48P36W INCLUDED Utility requirements for this equipment may vary. Always consult the serving utility for their requirements before ordering or installing equipment in this catalog. F1 CT CABINETS, TEST SWITCHES, POLYPHASE ENCLOSURES DOOR MOUNT C.T. RATED SOCKET F2 CURRENT TRANSFORMER CABINETS CT203611-HC CT18249-SC CT CABINETS, TEST SWITCHES, POLYPHASE ENCLOSURES SECTION F SCREW COVER CATALOG NUMBER C.T. RACKS SIZE W" X H" X D" FRONT COVER CT24329-SC CT242411-SC CT243011-SC CT243611-SC CT244811-SC CT303011-SC CT303611-SC CT303614-SC CT363611-SC CT364211-SC CT364811-SC CT364814-SC CT424211-SC CT484811-SC C, M A4, C, M A4, C, M A4, C, J, M A, C, D, G, J, M A4, B4, C, E, L, M A4, B4, C, E, J, K, L, M A4, B4, C, E, J, K, L, M A4, B4, C, E, J, K, L, M A4, B4, C, E, J, K, L, M A, B, C, D, E, F, G, H, J, K, L, M A, B, C, D, E, F, G, H, J, K, L, M A4, B4, C, E, J, K, L, M A, B, C, D, E, F, G, H, J, K, L, M 24 X 32 X 9 24 X 24 X 11 24 X 30 X 11 24 X 36 X 11 24 X 48 X 11 30 X 30 X 11 30 X 36 X 11 30 X 36 X 14 36 X 36 X 11 36 X 42 X 11 36 X 48 X 11 36 X 48 X 14 42 X 42 X 11 48 X 48 X 11 1 PIECE 1 PIECE 1 PIECE 1 PIECE 1 PIECE 1 PIECE 1 PIECE 1 PIECE 1 PIECE 2 PIECES 2 PIECES 2 PIECES 2 PIECES 2 PIECES HINGE COVER CATALOG NUMBER C.T. RACKS SIZE W" X H" X D" FRONT COVER CT203611-HC CT243011-HC CT243611-HC CT244811-HC CT303611-HC CT304811-HC CT363611-HC CT364811-HC CT484811-HC CT364814-HC CT484814-HC C A4, C, M C, M A, C, D, G, J, M A4, B4, C, E, J, K, L, M A, B, C, D, E, F, G, H, J, K, L, M A4, B4, C, E, J, K, L, M A, B, C, D, E, F, G, H, J, K, L, M A, B, C, D, E, F, G, H, J, K, L, M A, B, C, D, E, F, G, H, J, K, L, M A, B, C, D, E, F, G, H, J, K, L, M 20 X 36 X 11 24 X 30 X 11 24 X 36 X 11 24 X 48 X 11 30 X 36 X 11 30 X 48 X 11 36 X 36 X 11 36 X 48 X 11 48 X 48 X 11 36 X 48 X 14 48 X 48 X 14 1 PIECE 1 PIECE 1 PIECE 1 PIECE 1 PIECE 1 PIECE 1 PIECE 1 PIECE 2 PIECE 2 PIECE 2 PIECE ENCLOSURE: These units are rated Type 3R, powder coated, and constructed of galvanized steel. MOUNTING RACK: Select CT mounting rack from next page. MOUNTING: 1/4-20 welded studs. Utility requirements for this equipment may vary. Always consult the serving utility for their requirements before ordering or installing equipment in this catalog. F2 CURRENT TRANSFORMER CABINETS–MOUNTING RACKS K4798 K4797 K4793 / K4795 K4729 CODE CATALOG NUMBER AIC RATING AMPS VOLTS TYPE OF SERVICE TERMINATION TYPE A4 K4797 50K 400 600 1∅3W 1/2-13 studs on 1-3/4" centers A K4797 50K 800 600 1∅3W 1/2-13 studs on 1-3/4" centers B4 K4798 50K 400 600 3∅4W 1/2-13 studs on 1-3/4" centers B K4798 50K 800 600 3∅4W 1/2-13 studs on 1-3/4" centers C K4793 10K 201-400 600 1∅3W 1/2-13 studs on 1-3/4" centers D K4795 10K 401-800 600 1∅3W 1/2-13 studs on 1-3/4" centers E K4794 10K 201-400 600 3∅4W 1/2-13 studs on 1-3/4" centers F K4796 10K 401-800 600 3∅4W 1/2-13 studs on 1-3/4" centers G K4729 50K 800 600 1∅3W (3) #4 - 600 or (6) #1 - 250 H K4722 50K 800 600 3∅4W (3) #4 - 600 or (6) #1 - 250 J K4903 50K 400 600 1∅3W (1) #4 - 600 or (2) #1 - 250 K K4904 50K 400 600 3∅4W (1) #4 - 600 or (2) #1 - 250 L K5747 50K 800 600 3∅4W M K5752 50K 800 600 1∅3W Line: 1/2-13 studs on 1-3/4" centers Load: (3) #4 - 600 or (6) #1 - 250 Line: 1/2-13 studs on 1-3/4" centers Load: (3) #4 - 600 or (6) #1 - 250 Select CT enclosures from previous page. Utility requirements for this equipment may vary. Always consult the serving utility for their requirements before ordering or installing equipment in this catalog. F3 CT CABINETS, TEST SWITCHES, POLYPHASE ENCLOSURES CURRENT TRANSFORMER ENCLOSURE MOUNTING RACKS SECTION F K4722 F3 METERED TRANSFORMER CABINETS–OVERHEAD & UNDERGROUND CT CABINETS, TEST SWITCHES, POLYPHASE ENCLOSURES SECTION F F4 U3565-O METERED TRANSFORMER CABINETS—RING TYPE NO. DIMENSIONS OF TERMS D" W" H" 6 11 24 42 SERVICE HUB CATALOG NUMBER C.T. RACKS OH H.O. U3320-R A, C, D, J, L, M OH H.O. H.O. U3322-R B, E, F, G, H, L, M 13 11 36 42 3∅4W Υor Δ OH U3555-R B, E, F, G, H, L, M 15 11 36 42 3∅4W Υor Δ UG NONE U3340-O A, C, D, J, L, M 6 11 24 52 1∅3W UG NONE U3342-O B, E, F, G, H, L, M 13 11 36 52 3∅4W Υor Δ UG NONE U3565-O B, E, F, G, H, L, M 15 11 36 52 3∅4W Υor Δ TYPE OF SERVICE 1∅3W METER SOCKET: 20 amp current transformer meter socket built in. ENCLOSURE: NEMA Type 3R with screw cover. CURRENT TRANSFORMER MOUNTING: 1/4-20 welded studs. HUBS: For proper hub selection, see hub suffix chart in the accessory section. SEALING RINGS: Supplied with MR-4 screw type sealing ring. MOUNTING RACKS: For mounting rack information refer to previous page. Utility requirements for this equipment may vary. Always consult the serving utility for their requirements before ordering or installing equipment in this catalog. F4 20 AMP— 4, 5, 6, 7, 8, & 13 TERMINAL CURRENT TRANSFORMER RATED—RINGLESS / RING TYPE 2 1 4 F5 3 4 5 UC7237-RL UC7582-XL NO. METER OF FORM TERMS HUB 3S UC1290-XL 6 4S UC1299-XL 7 7,14,15 & 24S UC7233-XL 8 5S UC7235-XL 13 6,8,9S & (ALT) 10S 5 UC7237-XL DIMENSIONS CONCENTRIC K.O.ʼS CONNECTORS CU BYPASS D" W" H" 1 2 3 4 5 C.P. #14 - #10 PLUNGER* 35⁄16 8 14 11⁄2 11⁄4 11⁄4 2 11⁄4 1 C.P. #14 - #10 PLUNGER* 35⁄16 8 14 11⁄2 11⁄4 11⁄4 2 11⁄4 1 C.P. #14 - #10 PLUNGER* 5 3 ⁄16 8 14 11 11 11 ⁄4 2 11 ⁄4 1 C.P. #14 - #10 PLUNGER* 35⁄16 8 14 11⁄2 11⁄4 11⁄4 2 11⁄4 1 #14 - #10 PLUNGER* 3 ⁄16 14 11 11 11 2 11 1 C.P. 8 5 ⁄2 ⁄2 ⁄4 ⁄4 ⁄4 ⁄4 6 ⁄4 ⁄4 ⁄4 ⁄4 ⁄4 RING TYPE–PLUNGER TYPE BYPASS–OVERHEAD / UNDERGROUND NO. METER OF FORM TERMS 5 6 8 13 13 3S 4S 5S 6,8,9S & (ALT) 10S 6,8,9S & (ALT) 10S CATALOG NUMBER UC1291-RL UC1300-RL UC7544-RL HUB H.O. H.O. H.O. CONNECTORS CU BYPASS #14 - #4 MAX PLUNGER* #14 - #4 MAX PLUNGER* #14 - #4 MAX PLUNGER* UC7545-RL H.O. #14 - #4 MAX PLUNGER* UC7582-XL C.P. #14 - #10 NONE DIMENSIONS CONCENTRIC K.O.ʼS D" W" H" 1 2 3 4 5 5 8 14 11⁄2 11⁄4 11⁄4 2 11⁄4 1 11 11 ⁄4 2 11 ⁄4 1 2 11⁄4 1 3 ⁄16 6 ⁄4 5 8 14 11 5 8 14 11⁄2 11⁄4 11⁄4 11 11 ⁄4 2 11 ⁄4 1 11⁄4 11⁄4 2 11⁄4 1 3 3 ⁄16 ⁄16 ⁄2 5 ⁄16 8 14 11 3 ⁄16 8 14 11⁄2 3 5 ⁄2 ⁄4 ⁄4 ⁄4 ⁄4 ⁄4 ⁄4 HUBS: For proper hub selection see the hub suffix chart on the accessory page. *BYPASS: Plunger type bypass automatically closes when meter is removed. CONNECTORS: Units are supplied with sleeve type connectors (#14-#2) Utility requirements for this equipment may vary. Always consult the serving utility for their requirements before ordering or installing equipment in this catalog. F5 CT CABINETS, TEST SWITCHES, POLYPHASE ENCLOSURES CATALOG NUMBER SECTION F RINGLESS—PLUNGER TYPE BYPASS–OVERHEAD / UNDERGROUND F6 20 AMP–600 VAC–5, 6, 8, 13, & 15 TERMINAL CURRENT TRANSFORMER—TEST SWITCH PROVISION 2 1 3 4 5 6 3425 7636 3426 7461 3428 3423 1 3 2 1 3435 3436 3438 3433 3434 5 4 UC3423-XL UC3438-XL-TS080025 (with test switch factory installed) RINGLESS—WITH PROVISION FOR TEST SWITCH–TWO PIECE FRONT CT CABINETS, TEST SWITCHES, POLYPHASE ENCLOSURES SECTION F NO. OF SERVICE TERMS CATALOG NUMBER HUB DIMENSIONS CONCENTRIC K.O.ʼS CONNECTORS BYPASS D" W" H" 1 2 3 4 5 6 5 OH / UG UC3425-XL C.P. #14 - #2 NONE 51⁄8 12 20 11⁄4 11⁄4 11⁄4 11⁄4 11⁄4 1 1 4, 2 6 OH / UG UC3426-XL C.P. #14 - #2 NONE 1 5 ⁄8 12 20 11 11 11 11 11 ⁄4 1 1 4, 2 8 OH / UG UC3428-XL C.P. #14 - #2 NONE 51⁄8 12 20 11⁄4 11⁄4 11⁄4 11⁄4 11⁄4 1 1 4, 2 13 OH / UG UC3423-XL C.P. #14 - #2 NONE 5 ⁄8 12 20 11 11 11 11 11 1 1 4, 2 1 ⁄4 ⁄4 ⁄4 ⁄4 ⁄4 ⁄4 ⁄4 ⁄4 ⁄4 ⁄ ⁄ ⁄ ⁄ ⁄ ⁄ ⁄ ⁄ *RING TYPE—TEST SWITCH FACTORY PREWIRED—TWO PIECE FRONT APPROVED FOR TUCSON ELECTRIC POWER NO. OF SERVICE TERMS CATALOG NUMBER 6 OH UC7636-YL-TGE-DES 11⁄4" 13 OH UC7461-YL-TGE-DES ⁄4" 11 DIMENSIONS CONCENTRIC K.O.ʼS BYPASS D" W" H" 1 2 3 4 5 6 #14 - #2 TEST SWITCH 41⁄8 12 20 11⁄4 11⁄4 11⁄4 11⁄4 11⁄4 1 1 4, 2 #14 - #2 TEST SWITCH 41 12 20 11 11 11 11 11 1 1 4, 2 HUB CONNECTORS ⁄8 ⁄4 ⁄4 ⁄4 ⁄4 ⁄4 ⁄ ⁄ ⁄ ⁄ *RING TYPE—WITH PROVISIONS FOR TEST SWITCH—EUSERC COMPLIANT–TWO PIECE FRONT NO. OF SERVICE TERMS CATALOG NUMBER HUB DIMENSIONS CONCENTRIC K.O.ʼS CONNECTORS BYPASS D" W" H" 1 2 3 4 5 6 5 OH / UG UC3435-XL C.P. #14 - #2 NONE 51⁄8 12 20 2 2 2 2 2 — 6 OH / UG UC3436-XL C.P. #14 - #2 NONE 51⁄8 12 20 2 2 2 2 2 — 8 OH / UG UC3438-XL C.P. #14 - #2 NONE 51⁄8 12 20 2 2 2 2 2 — 13 OH / UG UC3433-XL C.P. #14 - #2 NONE 51⁄8 12 20 2 2 2 2 2 — 15 OH / UG UC3434-XL C.P. #14 - #2 NONE 51⁄8 12 20 2 2 2 2 2 — *SEALING RINGS: Ring type units are supplied with one MR-4, screw type, sealing ring. PREWIRING: If factory prewiring is required consult factory before ordering. Please include meter socket catalog number, test switch number, meter form number, and a copy of your wiring diagram. TEST SWITCH COVERS: Units on this page can be used with clear lexan cover (except units 7636 and 7461). CONNECTORS: Units are supplied with sleeve type connectors (#14-#2) HUBS: For proper hub selection see the hub suffix chart in accessory section. Utility requirements for this equipment may vary. Always consult the serving utility for their requirements before ordering or installing equipment in this catalog. F6 MILBANK TEST SWITCHES—4, 7, & 10 POLE SWITCH BLADES TEST SWITCH BASE POLARITY BARRIER Two dimples coined into one side of the switch blade ensure positive contact in corrosive, sooty environments—even after years of inactivity. The base is molded from a high strength, fiberglass reinforced, thermoset polyester. This material is track resistant, flame retardant and has low water absorption qualities. Bases are available in 7 pole and 10 pole sizes. For maximum protection potential circuits are supplied with permanently mounted, rigid barriers made from high tensile strength, polycarbonate. TEST SWITCH COVERS CURRENT CARRYING PARTS SWITCH JAWS FLUSH MOUNT COVER BLACK STANDARD COVER Units must be 5 1/8" deep for Cover K3388-BLK-FL K3388 FACTORY INSTALLED: For cover installed add the suffix -WC or -WCFL to the catalog number of desired test switch FIELD INSTALLED: For field installed cover order kit number K3388 or K3388-BLK-FL. The MILBANK test switch is designed to meet the critical requirements of the electric utility industry. Not only do they meet EEI, ANSI C12.9, and UL standards but they combine several special features giving the MILBANK test switch increased safety, durability and reliability. One such feature is our unique switch blade contact points which cut through residue that builds up after years of service. Another distinction is our polarity barrier which is designed to be flexible as well as offer exceptional insulating qualities. Our test switches are constructed from the latest materials available using modern fabricating and assembly methods. Utility requirements for this equipment may vary. Always consult the serving utility for their requirements before ordering or installing equipment in this catalog. F7 CT CABINETS, TEST SWITCHES, POLYPHASE ENCLOSURES The switch blade jaw clips are constructed from spring grade copper alloy. The material and design ensure excellent contact which prevents overheating. Highly conductive copper and copper alloy materials are used on all current carrying parts. This ensures conductivity and deters corrosion. Spring grades are used where appropriate. Plating is available if required. Contact general offices to special order. SECTION F Standard test switch covers are made from break resistant, clear, thermal plastic which has excellent tracking and moisture resistant properties. If covers are required, add suffix “-WC” (with cover) to the catalog number or order separately catalog number K3388. Black flush mount covers are also available. Order catalog number K3388-BLK-FL. 10 pole base only. F7 F8 TEST SWITCHES—4, 7 & 10 POLE—600 VAC–PER ANSI C12.9 STANDARD 3 1/2" 7 1/2" 3 1/2" CATALOG NUMBER CT CABINETS, TEST SWITCHES, POLYPHASE ENCLOSURES SECTION F 9 1/2" C+ C X P Pn X C+ C X TS04-0104 X C+ C X P Pn X C+ C 7-POLE TS07-0105 Potential Switch P P Pn C+ C Line side current switch with short circuit assembly Load side current switch with test jack assembly N Neutral bar ( no switch ) Pn Neutral potential switch X TS04-0101 CATALOG NUMBER KEY P 4-POLE CATALOG NUMBER 7-POLE ON A 10 POLE BASE TS07-0049 P X P X Pn X C+ C C C+ TS07-0106 X P C+ C P C+ C Pn X X Unused position on base Insulating barrier, isolates both sides of switch CATALOG NUMBER CUSTOM POLE ARRANGEMENTS: The key may be used to diagram your own pole arrangement. Be sure to specify base size and whether all C+ line side, current switch / shunt circuit assemblies are to be bussed together. The catalog numbers shown above are connected in line-load pairs; therefore, if bussed is required, different catalog numbers will apply. 10-POLE TS10-0109 P P P Pn C+ C C+ C C+ C TS10-0110 P C+ C P C+ C P C+ C Pn TS10-0111 P P P Pn C C+ C C+ C C+ TS10-0112 C+ C C+ C C+ C P P P Pn TS10-0016 P P P PN C C+ C C+ C C+ Utility requirements for this equipment may vary. Always consult the serving utility for their requirements before ordering or installing equipment in this catalog. F8 MILBANK TEST SWITCH WORKSHEET F9 CUSTOMER NAME: __________________________________________ ADDRESS: __________________________________________________ ____________________________________________________________ PHONE / FAX:_____________________ / ________________________ HANDLE COLOR KEY TEST SWITCH BASE The base is molded from a high strength, fiberglass reinforced, thermoset polyester. This material is track-resistant, flame-retardant and has low water absorption qualities. Bases are available in two standard sizes following NEMA mounting classifications. BK Black P Purple Y Yellow R Red BL Blue W White BR Brown GR Grey O GN Green BKS BK/Stripe Orange WS W/Stripe POLE POSITION CHART 1 2 3 4 5 6 7 8 9 10 FEATURE 1 2 3 4 5 6 7 8 9 10 GANGED HANDLES (C) BUSSING COLORED HANDLES ENGINEERING INFORMATION:____________________________________________________________________________ ______________________________________________________________________________________________________ ______________________________________________________________________________________________________ ______________________________________________________________________________________________________ ______________________________________________________________________________________________________ KEY P C+ C Potential Switch Line side current switch with short circuit assembly Load side current switch with test jack assembly N Neutral bar ( no switch ) Pn Neutral potential switch X Unused position on base Insulating barrier, isolates both sides of switch CUSTOM POLE ARRANGEMENTS: The key may be used to diagram your own pole arrangement. Be sure to specify base size and whether all C+ line side, current switch / shunt circuit assemblies are to be bussed together. The catalog numbers shown above are connected in line-load pairs; therefore, if bussed is required, different catalog numbers will apply. NUMBER OF POLES TEST SWITCH COVER* BASE SIZE 4 7 10 YES ___ CLEAR ___ BLACK NO 7 POLE 10 POLE *Test switch covers are only available for 10 pole bases. OTHER ______ Utility requirements for this equipment may vary. Always consult the serving utility for their requirements before ordering or installing equipment in this catalog. F9 CT CABINETS, TEST SWITCHES, POLYPHASE ENCLOSURES 45° ANGLE STOPS SECTION F SPECIAL FEATURES NOTES SECTION F F10 NOTES F10 125 AMP–MOBILE HOME METERED PEDESTAL–HARDWIRED–120/240 VAC G1 STANDARD CONFIGURATIONS 78" SERVICE PEDESTALS 49-1/2" GRADE LEVEL SECTION G 24" MPRV-100-MB-78 4" 8" SINGLE SPECIFICATIONS • UL Listed 100 amp continuous duty meter socket. • 120/240 volt single phase service. CATALOG NUMBER DESCRIPTION MPRV-BLANK-78 Ring type, parallel wired MPRV-BLANK-78-R-5T Ringless, horn bypass MPRV-100-78 Ring type, parallel wired • Space for four (4) single, or one double (240V C/B centerpositions only) and two (2) single pole universal style, plug-in circuit breakers. MPRV-100-MB-78 Ring type, series wired • Ringless version equipped with horn bypass as standard. MPRV-100-20GR-78 Ring type, parallel wired • For fifth terminal field installed order kit 105J in the 3 oʼclock or 9 oʼclock position. MPRV-50-78 Ring type • Direct rear feed kit PF-KR included. MPRV-503020GR-78 Ring type • Specify MPRV-100-78 for 100 amp service pedestal with direct feed kit and 100 amp CB wired in parallel. Space for two additional single pole CBs provided. Series wiring available; specify MPRV-100-MB-78. • Twin line termination lugs #6-350 kcmil CU/AL per phase for looping. • MR-2 sealing ring standard with ring type cover. • No knockouts. Utility requirements for this equipment may vary. Always consult the serving utility for their requirements before ordering or installing equipment in this catalog. G1 G2 200 AMP–MOBILE HOME METERED PEDESTAL—HARDWIRED—120/240VAC 9" 54" 49-1/2" 27" 78" SECTION G SERVICE PEDESTALS GRADE LEVEL 24" 4" 4" 8" STANDARD CONFIGURATIONS MPAP-200-78 A BLANK G N B 100A thru 200A 200-20GR 1-20A/125V SINGLE DOUBLE SPECIFICATIONS • 120/240 volt single phase service. CATALOG NUMBER DESCRIPTION MPAP-BLANK-78 Ring type, parallel wired MPAP-BLANK-78-R Ringless, horn bypass, parallel wired MPAP-100-78 Ring type, parallel wired MPAP-100-MB-78 Ring type, series wired MPAP-200-78 Ring type, parallel wired MPAP-200-MB-78 Ring type, series wired MPAP-200-20GR-78 Ring type, parallel wired MPAPD-BLANK-78 Ring type, parallel wired MPAPD-BLANK-78R Ringless, horn bypass, parallel wired • Twin line termination lugs #6-350 CU/AL per phase for looping. • UQFP breaker provisions factory wired in parallel with branch breaker bus. Series wiring available. Specify MB after breaker rating, ex. MPAP-200-MB. • Furnished with space for four single or one double (240V C/B center-positions only) and two single pole universal style, plug-in circuit breakers in addition to main. • Ringless version equipped with horn bypass as standard. • For fifth terminal field installed order kit 105J in the 3 oʼclock or 9 oʼclock position. • Direct rear feed kit PF-KR included. • MR-2 sealing ring standard with ring type cover. Utility requirements for this equipment may vary. Always consult the serving utility for their requirements before ordering or installing equipment in this catalog. G2 100 / 200 AMP—LOAD CENTER POWER PEDESTALS ALL PURPOSE & RV APPLICATIONS 10" G3 12 5/8" 30" ??" ??" 48" 80" 23-3/4" ??" 27" Grade Level SERVICE PEDESTALS 24" 6" 4" 8" N B 5 5 3 5 5 MPRV 2 5 5 4 1 5 5 MPAP 4 G1 N1 SECTION G A Left Side Only MPAP MPAP-200-MBLC-80 G 100 & 200 AMP—LOAD CENTER POWER OUTLETS CATALOG NUMBER DESCRIPTION MPRV-100-MBLC-80 MPAP-200-MBLC-80 CONCENTRIC K.O.ʼS (INCHES) 1 2 3 4 5 100 Amp Metered Pedestal with (8) Circuit Load Center 21⁄2 2 11⁄2 11⁄4 1 3 2, 4 200 Amp Metered Pedestal with (8) Circuit Load Center 21⁄2 2 11⁄2 11⁄4 1 3 2, 4 ⁄ ⁄ ⁄ ⁄ SPECIFICATIONS • UL Listed 100 / 200 amp continuous duty meter socket. • Approved for 120/240 volt single phase service. • Twin line termination lugs #6-350 CU/AL per phase for looping. Rear termination • Space for (8) single, or (4) double and two single pole universal style plug-in circuit breakers • Series main breaker factory installed. • Direct feed lugs standard. Utility requirements for this equipment may vary. Always consult the serving utility for their requirements before ordering or installing equipment in this catalog. G3 200 AMP SERIES U5240 & U5241 RING TYPE METERED PEDESTALS SECTION G SERVICE PEDESTALS G4 U5240-O-200S with series wired main & K5400-520GR kit SPECIFICATIONS • UL Listed – conforms to EUSERC drawing number 307 • 200 amp maximum, 120/240 volt, single phase, three wire meter socket • Ring type meter socket with stainless steel screw-type sealing ring • Short circuit withstand rating 22K AIC. • Type 3R construction for durable outdoor use, one piece post – lockable and sealable • Milbank grey polyester powder coat finish • Wire terminations accept copper or aluminum conductors • Line & Neutral: (2) #6-350 kcmil per phase • Line Ground: (4) #14-1/0 • Load (CB): 2/0 to 300 kcmil per pole • Load Neutral: (1) #6-350 kcmil • Load Ground: (2) #14-1/0, (4) #14/6 • Milbank plug-in main circuit breaker. Available in 100, 125, 150 & 200 amp. Type UQFPH-M. • Four-circuit plated copper interior accepts (2) 2-pole or (4) 1-pole standard plug-in type circuit breakers up to a total of 125 amps maximum. Acceptable manufacturers: Cutler-Hammer, GE or Siemens • Factory or field installable receptacle bridge and receptacle / circuit breaker kits available. See accessories. Utility requirements for this equipment may vary. Always consult the serving utility for their requirements before ordering or installing equipment in this catalog. G4 200 AMP SERIES U5240 & U5241 RING TYPE METERED PEDESTALS G5 SINGLE PEDESTAL (Direct Burial) CATALOG NUMBER MAIN BREAKER MAIN CB BRANCH WEIGHT (lbs) U5240-O-100S UQFPH-M-100 100 4 Circuit 82 U5240-O-200S UQFPH-M-200 200 4 Circuit 82 U5240-O (parallel wired) — 4 Circuit 80 200 4 Circuit 82 — 4 Circuit 80 provision for UQFPH-M Series SINGLE PEDESTAL (Pad Mount) U5242-O-200S UQFPH-M-200 U5242-O (parallel wired) provision for UQFPH-M Series DOUBLE PEDESTAL (Direct Burial) MAIN BREAKER MAIN CB BRANCH WEIGHT (lbs) U5241-O-100S (2) UQFPH-M-100 100 4 Circuit 115 U5241-O-200S (2) UQFPH-M-200 200 4 Circuit 115 U5241-O (parallel wired) provision for (2) UQFPH-M Series — 4 Circuit 111 — 4 Circuit 111 DOUBLE PEDESTAL (Pad Mount) U5243-O (parallel wired) provision for (2) UQFPH-M Series RECEPTACLE / CIRCUIT BREAKER KITS AND ACCESSORIES (ORDER SEPARATELY) RECEPTACLE CIRCUIT BREAKER CONDUCTOR CONFIGURATION K5400-520GR 5-20R Duplex GFI 20 Amp, 1 Pole 12 Awg K5400-TT30 TT30R 30 Amp, 1 Pole 10 Awg K5400-1450 14-50R 50 Amp, 2 Pole 8 Awg K5400-BRIDGE-1POS Self-grounded one position receptacle bridge with hardware K5400-BRIDGE-2POS Self-grounded two position receptacle bridge with hardware K5415 Stabilizer Foot with hardware K5035 Pad Mount Kit with hardware for U5242/43 pad mount pedestals required K5T 5th Terminal for 208y / 120 volt 3-wire service K5193 Bus kit to convert series-wired main breaker to parallel K5194 Wire kit to convert parallel-wired main breaker to series K3450 Telephone / CATV mounting bracket (mounts left or right) K5039 Penta bolt utility cover GFI Rec. • Up to two receptacle / circuit breaker kits can be field-installed in each powerhead. Order mounting bridge and receptacle kits separately from above. For three receptacles or factory-installed kits, contact factory. • Receptacle / circuit breaker kits include receptacle, circuit breaker, connected wire, cover plate and mounting screws. Other receptacle / circuit breaker kits available. • K5415 Stabilizer Foot sold separately. Recommended for double pedestals. • Pad mount pedestals require K5035 pad mount kit. Order separately. Stock item – availability subject to prior sale. Non-stock items – minimum order quantity required. Utility requirements for this equipment may vary. Always consult the serving utility for their requirements before ordering or installing equipment in this catalog. G5 SECTION G CATALOG # SERVICE PEDESTALS CATALOG NUMBER 200 AMP SERIES U5136 & U5137 RINGLESS METERED PEDESTALS SECTION G SERVICE PEDESTALS G6 U5136-O-200S with series wired main & K5400-520GR kit SPECIFICATIONS • UL Listed – conforms to EUSERC drawing number 307 • 200 amp maximum, 120/240 volt, single phase, three wire meter socket • Ringless meter socket with horn bypass and stainless steel latch • Short circuit withstand rating 22K AIC. • Type 3R construction for durable outdoor use, one piece post – lockable and sealable • Milbank grey polyester powder coat finish • Wire terminations accept copper or aluminum conductors • Line & Neutral: (2) #6-350 kcmil per phase • Line Ground: (4) #14-1/0 • Load (CB): 2/0 to 300 kcmil per pole • Load Neutral: (1) #6-350 kcmil • Load Ground: (2) #14-1/0, (4) #14/6 • Milbank plug-in main circuit breaker. Available in 100, 125, 150 & 200 amp. Type UQFPH-M. • Four-circuit plated copper interior accepts (2) 2-pole or (4) 1-pole standard plug-in type circuit breakers up to a total of 125 amps maximum. Acceptable manufacturers: Cutler-Hammer, GE or Siemens • Factory or field installable receptacle bridge and receptacle / circuit breaker kits available. See accessories. Utility requirements for this equipment may vary. Always consult the serving utility for their requirements before ordering or installing equipment in this catalog. G6 200 AMP SERIES U5136 & U5137 RINGLESS METERED PEDESTALS G7 SINGLE PEDESTAL (Direct Burial) CATALOG NUMBER MAIN BREAKER MAIN CB BRANCH WEIGHT (lbs) U5136-O-100S UQFPH-M-100 100 4 Circuit 82 U5136-O-200S UQFPH-M-200 200 4 Circuit 82 U5136-O (parallel wired) — 4 Circuit 80 200 4 Circuit 82 — 4 Circuit 80 provision for UQFPH-M Series SINGLE PEDESTAL (Pad Mount) U5138-O-200S UQFPH-M-200 U5138-O (parallel wired) provision for UQFPH-M Series DOUBLE PEDESTAL (Direct Burial) MAIN BREAKER MAIN CB BRANCH WEIGHT (lbs) U5137-O-100S (2) UQFPH-M-100 100 4 Circuit 115 U5137-O-200S (2) UQFPH-M-200 200 4 Circuit 115 U5137-O (parallel wired) provision for (2) UQFPH-M Series — 4 Circuit 111 RECEPTACLE / CIRCUIT BREAKER KITS AND ACCESSORIES (ORDER SEPARATELY) RECEPTACLE CIRCUIT BREAKER CONDUCTOR CONFIGURATION K5400-520GR 5-20R Duplex GFI 20 Amp, 1 Pole 12 Awg K5400-TT30 TT30R 30 Amp, 1 Pole 10 Awg K5400-1450 14-50R 50 Amp, 2 Pole 8 Awg K5400-BRIDGE-1POS Self-grounded one position receptacle bridge with hardware K5400-BRIDGE-2POS Self-grounded two position receptacle bridge with hardware K5415 Stabilizer Foot with hardware K5035 Pad Mount Kit with hardware for U5138/39 pad mount pedestals required K5T 5th Terminal for 208y / 120 volt 3-wire service K5193 Bus kit to convert series-wired main breaker to parallel K5194 Wire kit to convert parallel-wired main breaker to series K3450 Telephone / CATV mounting bracket (mounts left or right K5039 Penta bolt utility cover GFI Rec. • Up to two receptacle / circuit breaker kits can be field-installed in each powerhead. Order mounting bridge and receptacle kits separately from above. For three receptacles or factory-installed kits, contact factory. • Receptacle / circuit breaker kits include receptacle, circuit breaker, connected wire, cover plate and mounting screws. Other receptacle / circuit breaker kits available. • K5415 Stabilizer Foot sold separately. Recommended for double pedestals. • Pad mount pedestals require K5035 pad mount kit. Order separately. Stock item – availability subject to prior sale. Non-stock items – minimum order quantity required. Utility requirements for this equipment may vary. Always consult the serving utility for their requirements before ordering or installing equipment in this catalog. G7 SECTION G CATALOG # SERVICE PEDESTALS CATALOG NUMBER G8 U5706 & U5707 TEMP TO FINAL SERVICE PEDESTAL–RINGLESS/RING TYPE Concentric Knockouts A (4) = 1, 1-1/2, 2, 2-1/2” B (1) = 1-1/4, 1-1/2, 2” C (1) = 3/4”, 1” D (1) = 1/4”, 1/2” E (1) = 1” Solid Bridge Kit (4) .173” Extr. Holes E A B C A 30-3/16” SERVICE PEDESTALS A SECTION G A 19” D 13-1/4” 8-1/2” U5706-O-200P * (Shown with (2) K5400-520GR receptacles, K5400-BRIDGE-2POS & line side conductor installed.) OPEN 3-1/2” SPECIFICATIONS • 200 amp, 1∅, 120/240 volt, 22K AIC, underground service only. • U5706 has Ringless meter socket available with or without horn bypass (-KK). • U5707 has Ring type meter socket with MR-4 screw type meter ring. • Suitable for use as service equipment, mobile home service equipment and temporary power service equipment. *• Provisions for up to two Type 3R in-use receptacle kits. *• Order receptacle and bridge kits separately. See ordering information. • Direct burial pedestal suitable for free standing or structure mounted installation. • Separate line and load wireways are removable, lockable and sealable for security. • Left side is for utility connection. Right side is for customer underground load exit. • Convenient knockouts in post for thru-wall load exit requirements. • Type 3R enclosure constructed with type G90 galvanized steel. • Repaintable light gray polyester powder coat finish. • Wire terminations accept copper or aluminum conductors: Line & Neutral: #6-350 Ground: (4) #14-1/0. • Main circuit breaker can be series or parallel connected. • Universal 4 circuit branch 125 amp interior (up to (2) 2-pole) accepts most manufacturers plug-in type circuit breakers. See wiring diagram. Utility requirements for this equipment may vary. Always consult the serving utility for their requirements before ordering or installing equipment in this catalog. G8 U5706 & U5707 TEMP TO FINAL SERVICE PEDESTAL–RINGLESS/RING TYPE U5706 Ringless Pedestal Catalog Number Amps Service By-Pass Main Circuit Breaker Main Wired Replacement Main Type* Branch Circuits Weight LBS. U5706-O-200S 200 120/240 None 200a 2p Series UQFPH-M 4 79 U5706-O-200S-KK 200 120/240 Horn 200a 2p Series UQFPH-M 4 79 U5707 Ring Type Pedestal Catalog Number Amps Service By-Pass Main Circuit Breaker Main Wired Replacement Main Type* Branch Circuits Weight LBS. U5707-O-200S 200 120/240 None 200a 2p Series UQFPH-M 4 79 G9 Up to two receptacle/circuit breaker kits can be field or factory installed. See below for ordering information. Contact factory for factory installed kits. To increase pedestal height, order field-installed post extension kit K5708. For field installed fifth terminal in the 9 oʼclock position, order kit K5T. For field converting from parallel to series wired, order kit K5194. For field converting from series to parallel wired, order kit K5193. Receptacle / Circuit Breaker Kits & Receptacle Bridge Kits Amps/ Volts NEMA Config Circuit Breaker Conductor Configuration K5400-520GR 20a 120v 5-20R Duplex GFI 20a 1p 12 awg Fig. 1 K5400-620 20a 240v 6-20R Simplex 20a 2p 12 awg Fig. 2 K5400-620GB 20a 240v 6-20R Simplex 20a 240v GFI 12 awg Fig. 3 K5400-1450 50a 120/240v 14-50R 50a 120/240v 8 awg Fig. 4 K5400-1450GB 50a 120/240v 14-50R 50a 120/240v GFI 8 awg Fig. 4 Fig. 5 K5400-BRIDGE-2POS Self-grounded TWO position bridge with hardware and instructions. Fig. 6 Receptacle kits include: receptacle, circuit breaker, connected wire, cover plate, mounting screws and instructions. Contact factory for other kits. NOTE: Receptacle grounding is provided by metal contact with bridge and pedestal. Be sure to torque all fasteners per torque requirements. Stock item – availability subject to prior sale. Non-stock items – minimum order quantity required. Fig. 1 K5400-520GR Fig. 5 K5400-BRIDGE-1POS Fig. 2 K5400-620 Fig. 3 K5400-620GB Fig. 6 K5400-BRIDGE-2POS Fig. 4 K5400-1450 Fig. 7 UQFPH-M-200 Utility requirements for this equipment may vary. Always consult the serving utility for their requirements before ordering or installing equipment in this catalog. G9 SECTION G K5400-BRIDGE-1POS Self-grounded ONE position bridge with hardware and instructions. SERVICE PEDESTALS Catalog Number MOBILE HOME REBUILD KITS Catalog # 020-148-00-00-0 MPAP 200A interior rebuild kit Catalog # 020-147-00-00-0 MPRV 100A interior rebuild kit Catalog # RBK-1 Unicorn MPP (pre-1969) interior rebuild kit Catalog # Z1048284 MPAP, MPRV & Unicorn MPP lug landing assembly with grounding kit SECTION G SERVICE PEDESTALS G10 Above items sold as complete assemblies only. Individual components not available. Utility requirements for this equipment may vary. Always consult the serving utility for their requirements before ordering or installing equipment in this catalog. G10 MOBILE HOME REBUILD KITS Catalog # PF-KR MPAP / MPRV rear connector kit SERVICE PEDESTALS Catalog # PF-BL MPAP / MPRV blank deadfront with hinged cover G11 SECTION G Lug cover for MPAP / MPRV Order Catalog # 403456-SC 1 ⁄ (8 2" W x 201⁄2" H) for 72" pedestals and Cat. # 403457-SC (81⁄2" W x 261⁄2" H) for 78" pedestals. Utility requirements for this equipment may vary. Always consult the serving utility for their requirements before ordering or installing equipment in this catalog. G11 SERIES U5000–UNMETERED–SURFACE MOUNT POWER OUTLET SECTION H RV H1 U5000-XL-75 SPECIFICATIONS: UL Listed 125 Amp, 120/240 Volt, 1∅ Power Outlet. Short circuit current withstand rating 10K RMS symmetrical amperes. Type 3R welded enclosure for durable outdoor use. Enclosure constructed with galvanized 16 gauge steel. ASA 61 grey polyester powder coat finish. Convenient concentric knock-out configurations and mounting embosses. Hub opening with closure plate allows for meter retrofit. Wire terminations accept copper or aluminum conductors for loop feed wiring. Line: (2) 1/0-#12 Ground: (2) 1/0-#14 & (4) #6-#14 Neutral: (2) 1/0-#14 & (4) #6-#14 Six circuit plated copper interior accepts standard plug-in type circuit breakers. Rated up to 125 amps. Three position self-grounded receptacle bridge accepts most standard NEMA receptacles with mounting plates. Components factory wired with stranded copper wire. Lockable hinge cover and dead front are removable for installation and maintenance. Stay-open hinge cover has safety interlock on dead front. Dead front cover must be removed before hinge cover can be removed. Low wattage, 120 Volt fluorescent site light available. Factory or field installable. Unit weight: 21 lbs. Utility requirements for this equipment may vary. Always consult the serving utility for their requirements before ordering or installing equipment in this catalog. H1 SERIES U5000–UNMETERED–SURFACE MOUNT POWER OUTLET H2 U5000 STANDARD MODELS CATALOG # RECEPTACLES U5000-XL-41 (1) TT30R (1) 5-20R GFI (1) 30A, 1P, 120V (1) 20A, 1P, 120V U5000-XL-332 (2) TT30R (1) 5-20R GFI (2) 30A, 1P, 120V (1) 20A, 1P, 120V U5000-XL-55 (1) 14-50R (1) 5-20R GFI (1) 50A, 2P, 120/240V (1) 20A, 1P, 120V U5000-XL-75 (1) 14-50R (1) TT30R (1) 5-20R GFI (1) 50A, 2P, 120/240V (1) 30A, 1P, 120V (1) 20A, 1P, 120V (1) 14-50R (1) TT30R (1) 5-20R (1) 50A, 2P, 120/240V (1) 30A, 1P, 120V (1) 20A, 1P, 120V, GFI U5000-XL-75GB CIRCUIT BREAKERS U5000 STANDARD BASE MODEL Base model without receptacles or circuit breakers. RECEPTACLE & CIRCUIT BREAKER KITS CATALOG # RECEPTACLES K5400-520GR 5-20R Duplex GFI 20 Amp, 1 Pole 12 Awg GFI Rec. 5-20R Duplex 20 Amp, 1 Pole GFI 12 Awg GFI CB TT30R 30 Amp, 1 Pole 10 Awg TT30R 30 Amp, 1 Pole GFI 10 Awg 14-50R 50 Amp, 2 Pole 8 Awg K5400-520GB K5400-TT30 K5400-TT30GB K5400-1450 CIRCUIT BREAKERS CONDUCTORS CONFIGURATION GFI CB Stock model. Availability subject to prior sale. Note: 20 Amp GFI required at each RV site by UL and NEC 551-71 INTERNAL LIGHT KITS Factory or field installed. See accessory page. Utility requirements for this equipment may vary. Always consult the serving utility for their requirements before ordering or installing equipment in this catalog. H2 SECTION H U5000-XL RV Order up to (3) receptacle / breaker kits. Sold separately for field installation. CATALOG # DESCRIPTION H3 SERIES U5100–METERED–SURFACE MOUNT POWER OUTLET SECTION H RV Loop feed not available. U5100-XL-75 SPECIFICATIONS UL Listed 125 Amp, 120/240 Volt—1∅ Power Outlet. This is an overhead only unit. Short circuit current withstand rating 10K RMS symmetrical amperes. Type 3R welded enclosure for durable outdoor use. Enclosure constructed with galvanized 16 gauge steel. ASA 61 grey polyester powder coat finish. Convenient concentric knock-out configurations and mounting embosses. Hub opening with closure plate. Wire terminations accept copper or aluminum conductors. Loop feed not available. Line: (1) #6-250 kcmil Ground: (2) 1/0-#14 & (4) #6-#14 Neutral: (2) 1/0-#14 & (4) #6-#14 Six circuit plated copper interior accepts standard plug-in type circuit breakers. Rated up to 125 amps. Three position self-grounded receptacle bridge accepts most standard NEMA receptacles with mounting plates. Four terminal, drawn ring type meter socket with aluminum sealing ring. Ringless meter socket available. Use U5101 prefix. Components factory wired with stranded copper wire. Lockable hinge cover and dead front are removable for installation and maintenance. Stay-open hinge cover has safety interlock on dead front. Dead front must be removed before hinge cover can be removed. Low wattage, 120 Volt fluorescent site light available. Factory or field installable. Unit weight: 26 lbs. Utility requirements for this equipment may vary. Always consult the serving utility for their requirements before ordering or installing equipment in this catalog. H3 SERIES U5100–METERED–SURFACE MOUNT POWER OUTLET H4 U5100 STANDARD MODELS CATALOG # RECEPTACLES CIRCUIT BREAKERS U5100-XL-41 (1) TT30R (1) 5-20R GFI (1) 30A, 1P, 120V (1) 20A, 1P, 120V U5100-XL-55 (1) 14-50R (1) 5-20R GFI (1) 50A, 2P, 120/240V (1) 20A, 1P, 120V U5100-XL-75 (1) 14-50R (1) TT30R (1) 5-20R GFI (1) 50A, 2P, 120/240V (1) 30A, 1P, 120V (1) 20A, 1P, 120V U5100-XL-75GB (1) 14-50R (1) TT30R (1) 5-20R (1) 50A, 2P, 120/240V (1) 30A, 1P, 120V (1) 20A, 1P, 120V, GFI U5100-XL-552GR (2) 14-50R (1) 5-20R GFI (2) 50A, 2P, 120/240V (1) 20A, 1P, 120V, GFI U5100 STANDARD BASE MODELS Order up to (3) receptacle / breaker kits. Sold separately for field installation. CATALOG # DESCRIPTION U5101-XL Ringless-type base model without receptacles or circuit breakers. RECEPTACLE & CIRCUIT BREAKER KITS CATALOG # RECEPTACLES K5400-520GR 5-20R Duplex GFI 20 Amp, 1 Pole 12 Awg GFI Rec. 5-20R Duplex 20 Amp, 1 Pole GFI 12 Awg GFI CB TT30R 30 Amp, 1 Pole 10 Awg TT30R 30 Amp, 1 Pole GFI 10 Awg 14-50R 50 Amp, 2 Pole 8 Awg K5400-520GB K5400-TT30 K5400-TT30GB K5400-1450 CIRCUIT BREAKERS CONDUCTORS CONFIGURATION GFI CB Stock model. Availability subject to prior sale. Note: 20 Amp GFI required at each RV site by UL and NEC 551-71 INTERNAL LIGHT KITS Factory or field installed. See accessory page. Utility requirements for this equipment may vary. Always consult the serving utility for their requirements before ordering or installing equipment in this catalog. H4 SECTION H Ring-type base model without receptacles or circuit breakers. RV U5100-XL SERIES U5200–UNMETERED–PEDESTAL POWER OUTLET SECTION H RV H5 U5200-XL-75 DIRECT BURIAL SPECIFICATIONS UL Listed 125 Amp, 120/240 Volt—1∅ Power Outlet. Short circuit current withstand rating 10K RMS symmetrical amperes. Type 3R welded enclosure for durable outdoor use. Enclosure constructed with galvanized 16 gauge steel. Direct burial or pad mounted post constructed with 14 gauge galvanized steel. Two removable front covers for ease of installation. Accepts up to (3) 2 1/2” conduits. ASA 61 grey polyester powder coat finish. Convenient concentric knock-out configurations. See note A & B above. Hub opening with closure plate allows for meter retrofit. Wire terminations accept copper or aluminum conductors for loop feed wiring. Line: (2) #6-350 kcmil Ground: (2) #14-2/0 Neutral: (2) #6-350 kcmil Six circuit plated copper interior accepts standard plug-in type circuit breakers. Rated up to 125 amps. Three position self-grounded receptacle bridge accepts most standard NEMA receptacles with mounting plates. Components factory wired with stranded copper wire. Lockable hinge cover and dead front are removable for installation and maintenance. Stay-open hinge cover has safety interlock on dead front. Dead front must be removed before hinge cover can be removed. Low wattage, 120 Volt fluorescent site light available. Factory or field installable. Unit weight: Single–48 lbs. Double–70 lbs. Utility requirements for this equipment may vary. Always consult the serving utility for their requirements before ordering or installing equipment in this catalog. H5 SERIES U5200–UNMETERED–PEDESTAL POWER OUTLET H6 U5200 STANDARD MODELS SINGLE HEAD CATALOG # DBL. HEAD CATALOG# U5200-XL-41 U5220-XL-41 U5200-XL-41GB U5200-XL-332 U5200-XL-75 U5220-XL-75 U5200-XL-75GB RECEPTACLES CIRCUIT BREAKERS (1) TT30R (1) 5-20R GFI (1) 30A, 1P, 120V (1) 20A, 1P, 120V (1) TT30R (1) 5-20R (1) 30A, 1P, 120V (1) 20A, 1P, 120V, GFI (2) TT30R (1) 5-20R GFI (2) 30A, 1P, 120V (1) 20A, 1P, 120V (1) 14-50R (1) TT30R (1) 5-20R GFI (1) 50A, 2P, 120/240V (1) 30A, 1P, 120V (1) 20A, 1P, 120V (1) 14-50R (1) TT30R (1) 5-20R (1) 50A, 2P, 120/240V (1) 30A, 1P, 120V (1) 20A, 1P, 120V,GFI U5200 STANDARD BASE MODELS Order up to (3) receptacle / breaker kits. Sold separately for field installation. CATALOG # DESCRIPTION Single head base model on direct burial post. U5210-XL Single head base model on pad mount post. Order K5410 pad mount base separately. U5220-XL Double head base model on direct burial post. U5230-XL Double head base model on pad mount post. Order K5410 pad mount base separately. RV U5200-XL CATALOG # RECEPTACLES K5400-520GR 5-20R Duplex GFI 20 Amp, 1 Pole 12 Awg GFI Rec. 5-20R Duplex 20 Amp, 1 Pole GFI 12 Awg GFI CB TT30R 30 Amp, 1 Pole 10 Awg TT30R 30 Amp, 1 Pole GFI 10 Awg 14-50R 50 Amp, 2 Pole 8 Awg K5400-520GB K5400-TT30 K5400-TT30GB K5400-1450 CIRCUIT BREAKERS CONDUCTORS CONFIGURATION GFI CB Stock model. Availability subject to prior sale. Note: 20 Amp GFI required at each RV site by UL and NEC 551-71 INTERNAL LIGHT KITS Factory or field installed. See accessory page. Utility requirements for this equipment may vary. Always consult the serving utility for their requirements before ordering or installing equipment in this catalog. H6 SECTION H RECEPTACLE & CIRCUIT BREAKER KITS H7 SERIES U5300–METERED–PEDESTAL POWER OUTLET SECTION H RV U5310-O-75 PAD MOUNT DIRECT BURIAL SPECIFICATIONS UL Listed 125 Amp, 120/240 Volt—1∅ Power Outlet. Short circuit current withstand rating 10K RMS symmetrical amperes. Type 3R welded enclosure for durable outdoor use. Enclosure constructed with galvanized 16 gauge steel. Direct burial or pad mounted post constructed with 14 gauge galvanized steel. Two removable front covers for ease of installation. Accepts up to (3) 2 1/2” conduits. ASA 61 grey polyester powder coat finish. Wire terminations accept copper or aluminum conductors for loop feed wiring. Line: (2) #6-350 kcmil Ground: (2) #14-2/0 Neutral: (2) #6-350 kcmil Six circuit plated copper interior accepts standard plug-in type circuit breakers. Rated up to 125 amps. Three position self-grounded receptacle bridge accepts most standard NEMA receptacles with mounting plates. Four terminal, drawn ring type meter socket with aluminum sealing ring. Components factory wired with stranded copper wire. Lockable hinge cover and dead front are removable for installation and maintenance. Stay-open hinge cover has safety interlock on dead front. Dead front must be removed before hinge cover can be removed. Low wattage, 120 Volt fluorescent site light available. Factory or field installable. Unit weight: Single–53 lbs. Double–80 lbs. Utility requirements for this equipment may vary. Always consult the serving utility for their requirements before ordering or installing equipment in this catalog. H7 SERIES U5300–METERED–PEDESTAL POWER OUTLET H8 U5300 STANDARD MODELS SINGLE HEAD CATALOG # DBL. HEAD CATALOG# RECEPTACLES CIRCUIT BREAKERS U5300-O-41 (1) TT30R (1) 5-20R GFI (1) 30A, 1P, 120V (1) 20A, 1P, 120V U5300-O-55 (1) 14-50R (1) 5-20R GFI (1) 50A, 2P, 120/240V (1) 20A, 1P, 120V (1) 14-50R (1) TT30R (1) 5-20R GFI (1) 50A, 2P, 120/240V (1) 30A, 1P, 120V (1) 20A, 1P, 120V (2) 14-50R (1) 5-20R GFI (2) 50A, 2P, 120/240V (1) 20A, 1P, 120V U5300-O-75 U5320-O-75 U5300-O-552GR U5300 STANDARD BASE MODELS Order up to (3) receptacle / breaker kits. Sold separately for field installation. U5300-O Single head base model on direct burial post. U5310-O Single head base model on pad mount post. Order K5410 pad mount base separately. U5320-O Double head base model on direct burial post. U5330-O Double head base model on pad mount post. Order K5410 pad mount base separately. RECEPTACLE & CIRCUIT BREAKER KITS CATALOG # RECEPTACLES K5400-520GR 5-20R Duplex GFI 20 Amp, 1 Pole 12 Awg GFI Rec. 5-20R Duplex 20 Amp, 1 Pole GFI 12 Awg GFI CB TT30R 30 Amp, 1 Pole 10 Awg TT30R 30 Amp, 1 Pole GFI 10 Awg 14-50R 50 Amp, 2 Pole 8 Awg K5400-520GB K5400-TT30 K5400-TT30GB K5400-1450 CIRCUIT BREAKERS CONDUCTORS CONFIGURATION GFI CB Stock model. Availability subject to prior sale. Note: 20 Amp GFI required at each RV site by UL and NEC 551-71 INTERNAL LIGHT KITS Factory or field installed. See accessory page. Utility requirements for this equipment may vary. Always consult the serving utility for their requirements before ordering or installing equipment in this catalog. H8 SECTION H DESCRIPTION RV CATALOG # H9 MILBANK UTILITY GRADE 125 AMP DRAWN RING TYPE METER SOCKET REMOVABLE DEADFRONT TAMPER PROOF BARRIER BETWEEN RECEPTACLES & BREAKERS STANDARD COPPER FACTORY WIRING ON ALL RECEPTACLES AND CIRCUIT BREAKERS RECEPTACLES MOLDED FROM DURABLE NYLON MATERIAL SIX CIRCUIT 125 AMP INTERIOR WITH PLATED COPPER STABS & GLASS FILLED C/B BASE LOW WATTAGE FLUORESCENT LIGHT (OPTIONAL) RV GLASS FILLED LUG LANDING WITH TWIN #6-350 KCMIL LINE CONNECTORS FOR LOOP FEED WIRING LEFT & RIGHT LOCKING COVER PROVISIONS OPTIONAL LEFT OR RIGHT INSTALLATION PHOTO-ELECTRIC LIGHT CONTROL PAD LOCKABLE DEADFRONT PROVISION GFI RECEPTACLE WITH MISWIRE / TRIP INDICATOR LIGHT SELF-GROUNDED UNIVERSAL BRIDGE FOR UP TO THREE RECEPTACLES INSULATED BONDABLE MULTIPLE HOLE NEUTRAL BAR MULTIPLE HOLE GROUNDING BAR MILLENNIUM SERIES BY MILBANK SECTION H H9 MILLENNIUM FEATURES H10 ROLLED EDGE WIREWAY (NO SHARP EDGES) SLIP-ON LOCKING TABS FOR LOWER COVER STAINLESS STEEL LOCKING HASP& SEALING SCREW SECTION H REMOVABLE HINGE COVER WITH STAY OPEN & CLOSED SNAPS RV LIGHT LENS (OPTIONAL) U5300-O-75 (Illustrated) ONE PIECE WELDED POST CONSTRUCTION EASY TWO SCREW LOWER COVER REMOVAL TWIN #14-2/0 GROUND LUG MILLENNIUM FEATURES H10 H11 600 / 1200 AMP–PAD MOUNTED PANEL BOARD–120 / 240 VOLT–1∅ SPECIFICATIONS SECTION H RV 600 to 1200 amp, 120/240 Volt, 1∅ distribution bus accepts up to (6) 2 pole, 200 amp circuit breakers. Order from chart below. Costly main breaker not required per NEC 230-71. Economical alternative to costly wall hung or strut-mounted panel boards and load centers. Low profile, aesthetic design can be located near utility transformers or fed from a main service to a convenient location. Pad mounted Type 3R powder coated aluminum enclosure – Standard color is gray. Hinge door and lift off rear service door are lockable and sealable for security. NOTE: Consult local code enforcement for pad size requirements. Order Catalog # CP-24-PDMNT-CALT pad mount base or Catalog # CP-ABK5/8 anchor bolt kit separately. CIRCUIT BREAKERS CATALOG # CP3B-AUX-1200 AMPS PHASE VOLTS 1200 1∅ 120/240 LINE CONNECTORS (3) 1-600 kcmil / ∅ or (3) 2-250 kcmil / ∅ D W H 17" 24" 41" 200 AMP FRAME—PLUG-IN—10K AIC & 22K AIC TWO-POLE—COMMON TRIP UQFP WIRE RANGE 2-POLE RATING 10K AIC PLUG-IN 22K AIC PLUG-IN PKG QTY CU AL 100 UQFP-100 UQFPH-100 1 #3-#1 #1-1/0 125 UQFP-125 UQFPH-125 1 #3-#1 #1-1/0 150 UQFP-150 UQFPH-150 1 1/0-300 2/0-300 175 UQFP-175 UQFPH-175 1 1/0-300 2/0-300 200 UQFP-200 UQFPH-200 1 1/0-300 2/0-300 225 UQFP-225 UQFPH-225 1 1/0-300 2/0-300 Utility requirements for this equipment may vary. Always consult the serving utility for their requirements before ordering or installing equipment in this catalog. H11 100, 200 & 400 AMP–TERMINAL BOX–1∅ & 3∅–120 / 240 VOLT–600 VAC H12 U4540-XL RV SECTION H U4548 U4549 U4540 U4542 100, 200, & 400 AMP—TERMINAL BOXES—1∅ & 3∅—120/240 VOLT PHASE AMPS 1 100 VOLTS 120/240 CATALOG NUMBER HUB U4544-XL C.P. CONNECTORS 1∅ TO CU7AL 3∅ KIT (6) #12-1/0 K4543 3 100 600 U4546-XL C.P. (6) #12-1/0 N/A 1 200 120/240 U4540-XL C.P. (6) #6-350 K4539 3 1 3 200 400 400 600 120/240 600 U4542-XL U4548-RXL U4549-RXL C.P. (6) #6-350 N/A C.P. (3) #6-350 or (2) #4-600 (3) #6-350 or (2) #4-600 K4547 C.P. N/A DIMENSIONS D" W" 41⁄8 913⁄16 CONCENTRIC K.O.ʼS H" 1 2 3 4 5 18 — 2 2 1 1 1 4, 2 ⁄ ⁄ 13 ⁄8 9 ⁄16 18 — 2 2 1 1 1 4, 2 41⁄8 1413⁄16 23 — 11⁄4 21⁄2 21⁄2 1 1 4, 2 — 1 1 1 1 1 4, 2 1 4 1 14 5 151⁄2 4 ⁄8 5 13 15 ⁄16 23 1 27 ⁄2 27 3 3 1 ⁄4 3 3 2 ⁄2 2 ⁄2 ⁄ ⁄ ⁄ ⁄ ⁄ ⁄ 3 1 1 4, 2 ⁄ ⁄ 1 3 1 1 4, 2 1 ⁄ ⁄ ⁄4 ⁄4 HUB: Standard hub opening on top with closing plate attached. FEATURES: UL Listed pad lockable Type 3R enclosure. 3∅ 120/240V APPLICATION: Field installable 3∅ lug kit converts 1∅ unit to 3∅ unit. Utility requirements for this equipment may vary. Always consult the serving utility for their requirements before ordering or installing equipment in this catalog. H12 H13 LIGHTING ACCESSORIES INTERNAL LIGHT KITS FOR POWER OUTLETS Application: • Internal light kit for U5000 & U5200 UNMETERED power outlets. Features: • Includes 5 watt fluorescent lamp socket, ballast, lamp shield and opaque hinge cover lens. Factory wired to 20 amp GFI circuit. May be wired to separate 20 amp circuit breaker. Order Q120 separately. • Cover on unmetered power outlet is 19 1/8” in height. Ordering: • Order with -L suffix (after catalog number) for factory installed. • Order catalog number K5411 for field installed. Application: • Internal light kit for U5100 & U5300 METERED power outlets. Features: • Includes 5 watt fluorescent lamp socket, ballast, lamp shield and opaque hinge cover lens. Factory wired to 20 amp GFI circuit. May be wired to separate 20 amp circuit breaker. Order Q120 separately. • Cover on metered power outlet is 15 1/4” in height. Ordering: SECTION H RV • Order with -L suffix (after catalog number) for factory installed. • Order catalog number K5412 for field installed. PHOTOELECTRIC LIGHT CONTROL KIT Application: • Photoelectric light control kit for K5411 & K5412 light kits. Features: • 2.5 amp, 120 Volt photo electrical control wired in series with K5411& K5412 light kits. Ordering: • Order with -LPC suffix for factory installed light and PE control. • Order catalog number K5413 for field installed. WARNING: Always disconnect power prior to installing these devices. Utility requirements for this equipment may vary. Always consult the serving utility for their requirements before ordering or installing equipment in this catalog. H13 TELECOMMUNICATIONS AND PEDESTAL ACCESSORIES H14 TELEPHONE AND CABLE TV KIT Application: • Mounts to rear of pedestal series U5200 & U5300. May also be adaptable to a wooden or similar structure. Features: • Single: 16” galvanized raceway, (1) RJ11 telephone jack & (1) Type F coaxial CATV jack. • Dual: 16” galvanized raceway, (2) RJ11 telephone jack & (1) Type F coaxial CATV jack. • Includes mounting hardware & instructions. Ordering: • Single Line Telephone & Cable TV kit order catalog number K4709-02. • Weatherproof Type 3R “in-use” cover available. Add -3R to catalog numbers above. NOTE: • Confirm acceptability with Cable TV & Telephone provider before ordering or installing these devices. K4709-02 K4709-02-3R RV Application: • Used to cover water pipe and provide means to mount hose bib to rear of pedestal. Features: • Includes mounting hardware and instructions. • Matches K4709 kits when mounted side by side. 10 16 OD Ordering: • Order catalog number K4709-WS. 13 5/16 4 3 5/32 ID 2 1/2 OD 3 3/4 4 9/32 OD ref Utility requirements for this equipment may vary. Always consult the serving utility for their requirements before ordering or installing equipment in this catalog. H14 SECTION H WATER SHROUD WITH HARDWARE H15 PEDESTAL MOUNTING ACCESSORIES FIELD INSTALLED PAD MOUNT KIT Application: • Field installed pad mount kit with (6) 3/4” mounting holes. Features: • Includes 1/4-20 stainless steel hardware to attach pad mount base to post. • Anchor bolt kit sold separately (order catalog number K5421). Ordering: • Order catalog number K5410. STABILIZER FOOT WITH HARDWARE SECTION H RV Application: • Stabilizes direct burial type posts in unstable soil conditions. Features: • Includes 1/4-20 hardware to attach to U5200 & U5300 pedestals. Ordering: • Order catalog number K5415. ANCHOR BOLT KIT Application: • Concrete anchor bolt kit designed to attach pad mount base to concrete. Features: • (4) sets of zinc-plated 5/8-11 x 10” bolt with 2” toe. • Includes nut and flat washer. Ordering: • Order catalog number K5421. Utility requirements for this equipment may vary. Always consult the serving utility for their requirements before ordering or installing equipment in this catalog. H15 METERING & SINGLE RECEPTACLE ACCESSORIES H16 FIELD INSTALLED METER KITS Application: • Field installed meter kit for U5000 & U5200 power outlets. Features: • 100 amp cast meter socket, CL200 E-Z Read Meter, sealing ring, security seal, 1” Milbank hub, nipple and mounting screws. • Optional 1” liquid-tight hub available for existing units without extruded hub opening. See ordering information. • See CL200 for Watt-hour meter specifications. Ordering: • Order catalog number K4800-01. E-Z READ WATT-HOUR METER Application: • 200 Amp E-Z read watt-hour meter designed to be field installed on the U5100 & U5300 metered power outlets. Features: • 200 Amp Form 2S 120/240 Volt. • Numeric read-out in full kilowatt increments. No “tenths” dial. • Order catalog number CL200. Sold in multiples of (4) per carton. *SINGLE RECEPTACLE ONLY POWER OUTLET Application: • Overhead/underground power outlet receptacle, suitable for RV, temporary service, campground, marina & boatyard equipment. Features: • Type 3R, 120/240 Volt single phase. • Lockable cover. Ordering: • Order catalog number from chart below. WARNING: Always disconnect power prior to installing these devices. Utility requirements for this equipment may vary. Always consult the serving utility for their requirements before ordering or installing equipment in this catalog. H16 SECTION H Ordering: RV • Remanufactured to 1% accuracy. H17 RV REPLACEMENT PARTS & ACCESSORIES 708080-MO 20 amp GFI receptacle NEMA 520 K5400-520GR 20 amp 120V GFI receptacle and circuit breaker kit K5400-520GB 20 amp 120V receptacle and GFI circuit breaker kit 701776-MO 30 amp receptacle NEMA TT30 SECTION H RV K5400-TT30 30 amp 120V receptacle and circuit breaker kit K5400-1450 50 amp 120 / 240V receptacle and circuit breaker kit K5400-BRIDGE Receptacle bridge (3) position 708767-MO 50 amp receptacle NEMA 1450 K5400-NEUTRAL Neutral assembly K5400-BLANK Utility requirements for this equipment may vary. Always consult the serving utility for their requirements before ordering or installing equipment in this catalog. H17 RV REPLACEMENT PARTS & ACCESSORIES H18 Z917602-AC Circuit breaker base (6 circuit) Z918466-AC Lug landing base Z915141-AC Left or right meter block assembly Q120 20 amp 1 pole circuit breaker SEALING RING SNAP ACTION MR-2 RV 708784-MO 20 amp 1 pole GFI circuit breaker SECTION H Q130 30 amp 1 pole circuit breaker HINGE COVER Z918449-SC 19” Unmetered Z918447-SC 15” Metered Q250 50 amp 2 pole circuit breaker DEADFRONT Z818052-SC 19” Unmetered Z818480-SC 15” Metered Utility requirements for this equipment may vary. Always consult the serving utility for their requirements before ordering or installing equipment in this catalog. H18 H19 RV PRODUCT INFORMATION–WIRING DIAGRAM LABEL–WARRANTY U5300-O SERIES RATING: 125 amps maximum–120/240 VAC–1∅3W METER SOCKET: 100 amp continuous–600 VAC–Rainproof NEMA Type 3R Size of field installed conductors shall be 60°, 75°, or 90°C sized to 60°C rating for 110 Amps or less, and 75° C or 90°C sized to 75° C for 125 Amps and above. SHORT CIRCUIT CURRENT RATING: 10,000 RMS symmetrical amperes at 240 VAC maximum, but is limited to the lowest short circuit current rating of any installed circuit breaker. Watthour meter not included in short circuit current rating. REPLACEMENT CIRCUIT BREAKER: Must be the same type and rating. Use Milbank: UCP; Siemens/ITE: QP, QT; Cutler-Hammer /Westinghouse: QP, BD, BR; General Electric: TQ, THQ, THQL; Challenger: C, Q, QC, QP, A. FOR UNDERGROUND FEED ONLY SUITABLE FOR USE AS: Service equipment, mobile home service equipment, temporary power service equipment and recreational vehicle site supply power. See rating label below. WIRE TERMINAL INFORMATION—USE AL-CU CONDUCTORS TERMINAL WIRE RANGE TORQUE LB. / IN. Twin 350 kcmil - #6 250 Load, Neutral and Ground (large hole) 14 - 10 8 6-4 3 - 1/0 35 40 45 50 Load, Neutral and Ground (small hole) 14 - 10 8 6 20 25 35 DANGER On Hazard of Electrical Trip Shock or Burn TURN OFF POWER Off Supplying this equipment To reset breaker move to “off” before working inside then to “on” SECTION H RV Line & Neutral RECEPTACLE KIT RV K5400-520GR K5400-520GB K5400-TT30 K5400-TT30GB K5400-1450 K5400-BLANK R R A A A A A = Acceptable R = Required K5400-520GR or K5400-520GB required Shipping tends to loosen bolted connections. Check and tighten all hardware before energizing unit. WARRANTY If any equipment manufactured by seller fails due to defects in material or workmanship within one year from the date seller shipped the equipment, such equipment will be replaced or repaired at seller’s option. This warranty is limited to the repair or replacement of the equipment or component part or parts of the equipment and becomes void if any equipment failure is due to improper installation, purchaser’s negligence, unreasonable use, damage (not resulting from defects in material or workmanship) or misapplication. This warranty does not include reimbursement for the expense of installation, removal of the equipment from the line, transportation, or any other expenses which may be incurred. In no event shall seller be liable for consequential or incidental damages and seller’s liability for any and all losses and damages sustained by the purchaser or any other person arising out of or by reason of the use of the equipment, a defect in the equipment (whether discoverable or latent), a claim of negligence or for any other reason, shall not exceed the purchase price paid by the purchaser. THIS WARRANTY IS MADE EXPRESSLY IN LIEU OF ANY OTHER WARRANTY AND SELLER MAKES NO OTHER REPRESENTATION OR WARRANTY OF ANY OTHER KIND, EXPRESS OR IMPLIED, WITH RESPECT TO THE EQUIPMENT, WHETHER AS TO MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE OR ANY OTHER MATTER. AUTHORIZATION MUST BE OBTAINED FROM MILBANK’S GENERAL OFFICE BEFORE EQUIPMENT IS RETURNED. Utility requirements for this equipment may vary. Always consult the serving utility for their requirements before ordering or installing equipment in this catalog. H19 U4908/U4909 UNDERGROUND SERVICE POWER OUTLET–RINGLESS/RING TYPE I1 25 15/16 MILBANK 5 3/8 CL MILBANK 3 5/16 9” 5 1/4 1 5/8 U4909-O-11GR 3 4 3 4 Utility requirements for this equipment may vary. Always consult the serving utility for their requirements before ordering or installing equipment in this catalog. I1 SECTION I Available in ringless style (U4908 series) or ring type (U4909 series) UL Listed 100 Amp, 120/240 Volt – 1∅ Underground Service Power Outlet Short circuit current withstand rating 10K RMS symmetrical amperes Type 3R welded enclosure for durable outdoor use Enclosure constructed with galvanized 16 gauge steel ASA 61 grey polyester powder coat finish Convenient concentric knock-out configurations and mounting embosses Wire terminations accept copper or aluminum conductors Service–Line & Neutral: (1) #6-2/0 Load Ground: (2) 1/0-#14 & (4) #6-#14 Load Neutral: (2) 1/0-#14 & (4) #6-#14 Service Ground: #2-#8 Six circuit plated copper interior accepts standard plug-in type circuit breakers Three position self-grounded receptacle bridge accepts most standard NEMA receptacles with mounting plates Four terminal, ringless meter socket with stainless steel locking hasp. Ring type socket has aluminum MR-2 snap action sealing ring Lockable hinge cover and deadfront are removable for installation and maintenance. Stay-open hinge cover has safety interlock on deadfront. Deadfront must be removed before hinge cover can be removed. Tamper proof fastening available TEMPORARY POWER SPECIFICATIONS I2 U4908/U4909 UNDERGROUND SERVICE POWER OUTLET–RINGLESS/RING TYPE U4908 / U4909 STANDARD CONFIGURATIONS ORDERING INFORMATION CATALOG # SOCKET TYPE U4908-O Ringless DESCRIPTION Order base model and up to three factory installed receptacle/breaker kit separately TEMPORARY POWER from list below. Other kits available. Consult factory. U4908-O-11GR Ringless U4908-O-55GBGR Ringless U4909-O Ring type Order base model and up to three factory installed receptacle/breaker kit separately from list below. Other kits available. Consult factory. U4909-O-11GR Ring type U4909-O-55GBGR Ring type SECTION I RECEPTACLE & CIRCUIT BREAKER KITS CATALOG NUMBER AMP BLADE VOLTAGE NEMA CONFIG. TYPE K5400-520 20 Straight 120 5-20 Std. Duplex 20 Amp 1 Pole K5400-520GR 20 Straight 120 5-20 GFI Duplex 20 Amp 1 Pole K5400-620 20 Straight 240 6-20 Single 20 Amp 2 Pole K5400-620GB 20 Straight 240 6-20 Single 20 Amp 2 Pole GFI K5400-1450 50 Straight 120/240 14-50 Single 30 Amp 2 Pole K5400-1450GB 50 Straight 120/240 14-50 Single 30 Amp 2 Pole GFI CIRCUIT BREAKER TYPE Flat cover may not close completely with twist locking devices in use. Order slope-front 3R cover # 1107681 separately to use with twist lock type receptacles. Stock item – availability subject to prior sale. Non-stock items – minimum order quantity required Utility requirements for this equipment may vary. Always consult the serving utility for their requirements before ordering or installing equipment in this catalog. I2 SERIES U5000–UNMETERED–SURFACE MOUNT POWER OUTLET I3 U5000-XL-38GR TEMPORARY POWER SPECIFICATIONS: UL Listed 125 Amp, 120/240 Volt, 1∅ Power Outlet. Short circuit current withstand rating 10K RMS symmetrical amperes. Type 3R welded enclosure for durable outdoor use. Enclosure constructed with galvanized 16 gauge steel. ASA 61 grey polyester powder coat finish. Convenient concentric knock-out configurations and mounting embosses. Hub opening with closure plate installed. Wire terminations accept copper or aluminum conductors for loop feed wiring. Line: (2) 1/0-#12 Ground: (2) 1/0-#14 & (4) #6-#14 Neutral: (2) 1/0-#14 & (4) #6-#14 Six circuit plated copper interior accepts standard plug-in type circuit breakers. Three position self-grounded receptacle bridge accepts most standard NEMA receptacles with mounting plates. Components factory wired with stranded copper wire. Lockable hinge cover and dead front are removable for installation and maintenance. Stay-open hinge cover has safety interlock on dead front. Dead front cover must be removed before hinge cover can be removed. NOTE: Cover may not close completely with twist-locking devices in use. Tamper proof fastening available. Utility requirements for this equipment may vary. Always consult the serving utility for their requirements before ordering or installing equipment in this catalog. I3 SECTION I I4 SERIES U5000–UNMETERED–SURFACE MOUNT POWER OUTLET SECTION I TEMPORARY POWER U5000 STANDARD CONFIGURATIONS ORDERING INFORMATION CATALOG # DESCRIPTION U5000-XL-(*) (*) Add suffix from above chart to complete catalog number (ie: U5000-XL-11GR) U5000-XL Order base model and up to three factory installed receptacle/breaker kit separately from list below. Other kits available. Consult factory. RECEPTACLE & CIRCUIT BREAKER KITS CATALOG NEMA NUMBER AMP BLADE VOLTAGE CONFIG. TYPE CIRCUIT BREAKER TYPE K5400-520 20 Straight 120 5-20 Std. Duplex 20 Amp 1 Pole K5400-520GR 20 Straight 120 5-20 GFI Duplex 20 Amp 1 Pole K5400-620 20 Straight 240 6-20 Single 20 Amp 2 Pole K5400-620GB 20 Straight 240 6-20 Single 20 Amp 2 Pole GFI K5400-1450 50 Straight 120/240 14-50 Single 30 Amp 2 Pole K5400-1450GB 50 Straight 120/240 14-50 Single 30 Amp 2 Pole GFI * Cover may not close completely while in use with Twist-Locking devices. Utility requirements for this equipment may vary. Always consult the serving utility for their requirements before ordering or installing equipment in this catalog. I4 SERIES U5001–UNMETERED–SURFACE MOUNT POWER OUTLET TEMPORARY POWER U5001-RL-01 SPECIFICATIONS: UL Listed 125 Amp, 120/240 Volt, 1∅ Power Outlet. Short circuit current withstand rating 10K RMS symmetrical amperes. Type 3R welded enclosure for durable outdoor use. ASA 61 grey polyester powder coat finish. Wire terminations accept copper or aluminum conductors. Line: 1/0-#4 Ground/Neutral: (4) 1/0-#14 & (11) #14-#6 Six circuit plated copper interior accepts standard plug-in type circuit breakers. Components factory wired with stranded copper wire. Lockable hinge cover and dead front are removable for installation and maintenance. U5001-RL-01 includes: (1) L6-30 (1) 30A, 2P, 240V GFI Breaker (2) L5-20 (2) 20A, IP, 120V GFI Breaker Utility requirements for this equipment may vary. Always consult the serving utility for their requirements before ordering or installing equipment in this catalog. I5 SECTION I I5 SECTION I TEMPORARY POWER I6 SERIES U5100 & U5101–OVERHEAD–RING & RINGLESS– METERED–SURFACE MOUNT POWER OUTLET U5100-XL-11GR SPECIFICATIONS Available in ringless style (U5101 series) or ring type (U5100 series). UL Listed 125 Amp, 120/240 Volt—1∅ Power Outlet. Short circuit current withstand rating 10K RMS symmetrical amperes. Type 3R welded enclosure for durable outdoor use. Enclosure constructed with galvanized 16 gauge steel. ASA 61 grey polyester powder coat finish. Convenient concentric knock-out configurations and mounting embosses. Hub opening with closure plate installed. Wire terminations accept copper or aluminum conductors. Line: (1) #6-250 kcmil Ground: (2) 1/0-#14 & (4) #6-#14 Neutral: (2) 1/0-#14 & (4) #6-#14 Six circuit plated copper interior accepts standard plug-in type circuit breakers. Three position self-grounded receptacle bridge accepts most standard NEMA receptacles with mounting plates. Four terminal, ringless meter socket with stainless steel locking hasp. Components factory wired with stranded copper wire. Lockable hinge cover and dead front are removable for installation and maintenance. Stay-open hinge cover has safety interlock on dead front. Dead front must be removed before hinge cover can be removed. NOTE: Cover may not close completely with twist-locking devices in use. Tamper proof fastening available. Utility requirements for this equipment may vary. Always consult the serving utility for their requirements before ordering or installing equipment in this catalog. I6 MILBANK I7 U5100 & U5101 STANDARD CONFIGURATIONS ORDERING INFORMATION DESCRIPTION U5100-XL-(*) Ring type (*) Add suffix from above chart to complete catalog number (ie: U5100-XL-11GR) U5100-XL Ring type Order base model and up to three factory installed receptacle/breaker kit separately from list below. Other kits available. Consult factory. U5101-XL-(*) Ringless (*) Add suffix from above chart to complete catalog number (ie: U5101-XL-11GR) U5101-XL Ringless Order base model and up to three factory installed receptacle/breaker kit separately from list below. Other kits available. Consult factory. CATALOG NEMA NUMBER AMP BLADE VOLTAGE CONFIG. TYPE CIRCUIT BREAKER TYPE K5400-520 20 Straight 120 5-20 Std. Duplex 20 Amp 1 Pole K5400-520GR 20 Straight 120 5-20 GFI Duplex 20 Amp 1 Pole K5400-620 20 Straight 240 6-20 Single 20 Amp 2 Pole K5400-620GB 20 Straight 240 6-20 Single 20 Amp 2 Pole GFI K5400-1450 50 Straight 120/240 14-50 Single 30 Amp 2 Pole K5400-1450GB 50 Straight 120/240 14-50 Single 30 Amp 2 Pole GFI * Cover may not close completely while in use with Twist-Locking devices. Utility requirements for this equipment may vary. Always consult the serving utility for their requirements before ordering or installing equipment in this catalog. I7 SECTION I RECEPTACLE & CIRCUIT BREAKER KITS TEMPORARY POWER CATALOG # SOCKET TYPE SECTION I TEMPORARY POWER I8 REPLACEMENT PARTS FOR MPAP / MPRV / HP PEDESTALS CATALOG # CIRCUIT BREAKER DESCRIPTION Q115 15 Amp—1 Pole—120/240—Plug-In Circuit Breaker Q120 20 Amp—1 Pole—120/240—Plug-In Circuit Breaker Q130 30 Amp—1 Pole—120/240—Plug-In Circuit Breaker Q220 20 Amp—2 Pole—120/240—Plug-In Circuit Breaker Q250 50 Amp—2 Pole—120/240—Plug-In Circuit Breaker Q2100 100 Amp—2 Pole—120/240—Plug-In Circuit Breaker 708784-MO 20 Amp—GFCI—1 Pole—120/240—Plug-In Circuit Breaker 708785-MO 30 Amp—GFCI—1 Pole—120/240—Plug-In Circuit Breaker 707915-MO 50 Amp—GFCI—2 Pole—120/240—Plug-In Circuit Breaker 703997-MO 50 Amp—Quad—2 Pole—120/240—Circuit Breaker CATALOG # RECEPTACLE DESCRIPTION 708777-MO 20 Amp—120V—NEMA 5-20R—Duplex Receptacle 708080-MO 20 Amp—120V—NEMA 5-20—GFCI Duplex Receptacle 704995-MO 20A—250V—NEMA 6-20R—Single Receptacle 701776-MO 30 Amp—120V—NEMA TT-30R—Travel Trailer Receptacle 706761-MO 50A—120V—3 Pole—3 Wire—NEMA 10-50R—Receptacle Z700911-MO 50A—120/250V—3 Pole—4 Wire—NEMA 14-50R—Receptacle CATALOG # LUG LANDINGS & BREAKER BASE DESCRIPTION Z020-509-01-00-0 MPRV / MPAP—Lug Landing (Twin #6-350 KCMIL) Z020-148-00-00-0 MPAP—Complete Interior Assembly *NOTE: The following brand names may be supplied when replacement circuit breakers are ordered: Cutler-Hammer/ Westinghouse—QP, BQC, BD, BR. Siemens/ITE—Q, QT. General Electric—TQ, THQ, THQL. Challenger—C, Q, QC, QP. Contact sales office for brand specific requirements. Utility requirements for this equipment may vary. Always consult the serving utility for their requirements before ordering or installing equipment in this catalog. I8 GALVANIZED STEEL DISTRIBUTION TRANSFORMER–1∅ J1 DRY TYPE TRANSFORMERS WITH DISTRIBUTION FOR RV & MOBILE HOME PARK APPLICATIONS 480 VOLTS TO 120/240 SINGLE PHASE KVA CAT. NO. WT. 75 100 167 1⁄2 200 250 7URMD 10URMD 16URMD 20URMD 25URMD 850# 1050# 1400# 1650# 1950# VOLTAGE 480V, A 2400V, A A 48″ 48″ DIMENSIONS B C 38″ 40″ 41″ 53″ B C 2400 VOLTS TO 120/240 SINGLE PHASE CAT. NO.* WT. 75 100 167 1⁄2 200 250 7URMD24 10URMD24 16URMD24 20URMD24 25URMD24 1050# 1200# 1650# 1900# 2200# A Specifications • Built in accordance with NEMA, ASA and AIEEE standards. Designed and tested to withstand 150% of rated load for two hours continuously. 480 Volt units are UL listed. Consult local utility for acceptance of this product. • Primary and / or secondary main circuit breaker protection available. Consult local utility for 480 volt overcurrent protection requirements. Single fuse primary overcurrent protection provided on 2400 volt and above units. • Other primary voltages available: 4160, 4800, 7200, 7960, & 12,470. Consult factory. Not UL listed. CORE AND COIL: DISTRIBUTION BUS: ENCLOSURE: • Aluminum wound (Copper available) • Standard voltage taps @ 2FCAN and 4FCBN • Rated at 150° C temperature rise • 1600 Amp tin plated aluminum • Space available for up to (12) circuit breakers – 1600 amp maximum • Uses Milbank type UQFP-100 through 200 amp circuit breakers (See page 18) • Type 3R enclosure • Powder coated galvanized steel (aluminum available) • Lockable primary and secondary doors • Lifting hooks and fork lift slots provided * These models are not UL listed. J1 SECTION J • Integrated design of the enclosure, core and coil, and secondary distribution panel permits convenient vertical line and load terminations. TRANSFORMERS KVA SECTION J NOTES J2 NOTES J2 ACCESSORIES K1 INTERCHANGEABLE UNIT HUBS HUB ADAPTER PLATE (Converts 4″ opening to 21⁄2″) S8324 SMALL “RL" OPENING (STANDARD) SUFFIX SIZE MILBANK NO. WL YL ZL DL EL 1″ 11⁄4″ A7514 A7515 A7516 A7517 A7518 11⁄2″ 2″ 21⁄2″ LARGE “R” OPENING (HEAVY DUTY) SUFFIX SIZE MILBANK NO. F G H 3″ 31⁄2″ 4″ A8110 A8111 A8112 REMOVABLE HUB CLOSING PLATE DESCRIPTION SUFFIX CAT. # STANDARD (for -RL opening) -XL A7551 LARGE (for -R opening) -X A9064 CLOSING COVERS HUB SUFFIX CHART O RL R XL X Plain Top Small Hub Opening Large Hub Opening Small Closing Plate Large Closing Plate Large Hub Opening RXL adapted to small Closing Plate METAL CLOSING PLATE (For Ringless sockets) CP-21 Large Hub Opening RRL adapted to small Hub Opening G 31⁄2″ For -R Opening H 4″ For -R Opening ACCESSORIES & MISCELLANEOUS METER CLOSING PLATE (Ring type / Ringless) 6003 (Gray Plastic) 6116 (Clear Plastic) WL 1″ For -RL Opening YL 11⁄4″ For -RL Opening ZL 11⁄2″ For -RL Opening DL 2″ For -RL Opening EL 21⁄2″ For -RL Opening 3″ For -R Opening F (For Ring type sockets) MCP CONNECTOR KITS For use with 3/8”-16 stud type units only SINGLE TWIN CATALOG # (3 per set) – 1 ∅ K1 K1539 K3 K1540 6-350 4-600 or (2) 1/0-250 4-600 or (2) 1/0-250 Non-rotating K3L K1540L SUFFIX CATALOG # (4 per set) – 3 ∅ K5 K3082 6-350 4-600 or (2) 1/0-250 K7 K3441 SUFFIX CATALOG # K2 K1350 K2L K1350L K4 K1541 SUFFIX CATALOG # K6 K8 K3442 K3083 (3 per set) – 1 ∅ 6-350 6-350 Non-rotating 4-600 (4 per set) – 3 ∅ 6-350 4-600 Utility requirements for this equipment may vary. Always consult the serving utility for their requirements before ordering or installing equipment in this catalog. K1 SECTION K SUFFIX K2 ACCESSORIES SEALING RINGS FIFTH TERMINALS Consult factory for 5th terminal selection 100-200 amp “PLUG-IN” FIFTH TERMINAL 5T8K2 HEAVY DUTY JAW CLAMPING K3865 (K3866 w/out neutral wire) SNAP ACTION MR-2 SCREW TYPE (Stainless Steel) MR-4 STAINLESS STEEL MR2-SS LOAD TAP CONNECTORS SECTION K ACCESSORIES & MISCELLANEOUS 200 amp FIFTH TERMINAL K5T (New style block with square hole) BYPASS LINK DISCONNECT SLEEVE * M5-144 (*NOT TO BE USED WITH LEVER BYPASS SOCKETS) K8180 (Bypass links sold in pairs) Utility requirements for this equipment may vary. Always consult the serving utility for their requirements before ordering or installing equipment in this catalog. K2 UQFP PLUG-IN SERIES CIRCUIT BREAKERS K3 UQFP 200 AMP FRAME—PLUG-IN—10,000 AIC & 22,000 AIC TWO-POLE—COMMON TRIP 10K AIC PLUG-IN 22K AIC PLUG-IN 100 UQFP-100 UQFPH-100 125 UQFP-125 150 AMPS 10K AIC PLUG-IN 22K AIC PLUG-IN WIRE RANGE AL UQFP-M-100 UQFPH-M-100 #3-#1 #1-1/0 UQFPH-125 UQFP-M-125 UQFPH-M-125 #3-#1 #1-1/0 UQFP-150 UQFPH-150 UQFP-M-150 UQFPH-M-150 1/0-300 2/0-300 175 UQFP-175 UQFPH-175 UQFP-M-175 UQFPH-M-175 1/0-300 2/0-300 200 UQFP-200 UQFPH-200 UQFP-M-200 UQFPH-M-200 1/0-300 2/0-300 UL LISTED: For use with 60°C or 75°C wire. UQFP: For parallel main circuit breaker applications UQFP-M: For series main circuit breaker applications. Split load tab features allow for feed through capability. STANDARD PACKAGING: 5 units per 16 lb. carton. Utility requirements for this equipment may vary. Always consult the serving utility for their requirements before ordering or installing equipment in this catalog. K3 SECTION K CU ACCESSORIES & MISCELLANEOUS UQFP-M K4 UQFB BOLT-ON SERIES CIRCUIT BREAKERS UQFB-X SECTION K ACCESSORIES & MISCELLANEOUS UQFB-X1 UQFB UQFB-X-MOD 200 AMP FRAME—BOLT-ON—10K AIC & 22K AIC TWO-POLE—COMMON TRIP 10K AIC BOLT-ON 22K AIC BOLT-ON 100 UQFB-100 125 AMPS 10K AIC BOLT-ON WIRE RANGE CU AL UQFBH-100 UQFB-100-X1 #3-#1 #1-1/0 UQFB-125 UQFBH-125 UQFB-125-X1 #3-#1 #1-1/0 150 UQFB-150 UQFBH-150 UQFB-150-X1 1/0-300 2/0-300 175 UQFB-175 UQFBH-175 UQFB-175-X1 1/0-300 2/0-300 200 UQFB-200 UQFBH-200 UQFB-200-X1 1/0-300 2/0-300 UL LISTED: For use with 60°C or 75°C wire. UQFB: (2) 1/0-300 kcmil lugs provided on load and line side (cable-in, cable-out.) UQFB3: Three pole available. Consult factory. UQFB-X: (2) 1/0-300 kcmil lugs provided on load side and (2) line bar bus connections on line side. UQFB-M: For series main circuit breaker applications. Split load tab features allow for feed through capability. UQFB-X-MOD: Replacement circuit breaker with line barriers removed. STANDARD PACKAGING: 5 units per 16 lb. carton. Utility requirements for this equipment may vary. Always consult the serving utility for their requirements before ordering or installing equipment in this catalog. K4 CONDUIT, AMPACITY & SCCR INFORMATION MAXIMUM NUMBER OF CONDUCTORS IN CONDUIT* CONDUCTOR SIZE AWG,MCM TYPE RHW & RHH (without outer covering) THW TW THW FEPB (6 thru 2), RHW and RHH (without outer covering) RH, THHW *CU CONDUIT TRADE SIZES (INCHES) 1 ⁄2 3 ⁄4 1 11⁄4 11⁄2 2 21⁄2 14 12 10 8 6 4 4 1 10 8 6 3 16 13 11 5 29 24 19 10 40 32 26 13 65 53 43 22 93 76 61 32 143 192 117 157 95 127 163 49 66 85 6 1 2 3 7 10 16 23 36 48 62 3 1 1 2 4 6 10 15 23 31 40 1 1 1 1 1 1 1 2 1 1 1 3 3 2 1 5 5 4 3 8 7 6 5 12 10 9 7 16 14 12 10 21 18 15 13 1 1 1 1 1 1 1 1 1 1 1 1 2 2 1 1 1 4 3 3 2 1 6 5 4 4 3 8 7 6 5 4 10 9 8 7 6 1 1 1 1 1 1 1 1 1 3 2 2 4 3 3 5 4 4 1/0 2/0 3/0 4/0 250 300 350 400 500 600 700 750 3 31⁄2 4 *This table is for concentric stranded conductors only. For cables with compact conductors refer to N.E.C. AL or Cu-Clad AL A B A C 18 16 14 12 10 8 — — 20 25 35 50 — — — 12 10 8 — — — 20 30 40 6 4 3 2 1 65 85 100 115 130 6 4 3 2 1 50 65 75 90 100 1/0 2/0 3/0 4/0 150 175 200 230 1/0 2/0 3/0 4/0 120 135 155 180 250 300 350 400 500 255 285 310 335 380 250 300 350 400 500 205 230 250 270 310 600 700 750 420 460 475 600 700 750 340 375 385 * Allowable ampacities of insulated A = Size: AWG/MCM B = Ampere Rating for Insulation Types: FEPW, RH, RHW, THW, THWN, XHHW, USE, 2W. C = Ampere Rating for Insulation Types: RH, RHW, THW, THWN, XHHW, USE (Per NEC table 310-16) 100A / POS. AMPACITY 200A 200A 200A 225A 270A 125A / POS. AMPACITY 200A 225A 250A 285A 330A 150A / POS. AMPACITY 200A 225A 270A 338A 396A 200A / POS. AMPACITY 200A 270A 360A 450A 528A All meter sockets are 600 volt rated unless otherwise noted. All meter socket ampacity ratings are continuous duty unless otherwise noted. K5 AMBIENT TEMP.C° 21 - 25 26 - 30 31 - 35 36 - 40 41 - 45 46 - 50 51 - 55 56 - 60 61 - 65 66 - 70 CORRECTION FACTOR 1.05 1.00 .94 .88 .82 .75 .67 .58 .33 — AMBIENT TEMP.F° 70 - 77 79 - 86 88 - 95 97 - 104 106 - 113 115 - 122 124 - 131 133 - 140 142 - 158 160 - 176 SECTION K GANG SOCKET OVERALL AMPACITIES NO. OF METER POSITIONS 2 3 4 5 6 AMPACITY CORRECTION FACTORS ACCESSORIES & MISCELLANEOUS Copper & Aluminum conductors (3W in conduit) 75°C (167°F) Unless otherwise permitted elsewhere in the Code, the overcurrent protection for conductor types marked with an obelisk ( ) shall not exceed 15 amps for 14 AWG, 20 amps for 12 AWG, and 30 amps for 10 AWG copper: or 15 amps for 12 AWG and 25 amps for 10 AWG aluminum and copper-clad aluminum after any correction factors for ambient temperature and number of conductors have been applied. Overall ampere ratings of UL Listed Milbank multiple position meter sockets are based on 1993 N.E.C. Manual article 220-32 and ANSI / UL-414 (except where restricted by line connector size.) These requirements provide for a diversity factor / demand factor being utilized in determining the overall (main bus / lug) rating of a gang socket. All Milbank UL Listed gang sockets meet or exceed these diversity factor/demand factor requirements. Standard overall ampacity ratings for UL Listed and non UL Listed gang sockets are as shown in the chart below. Ampere ratings of meter sockets are based on the meter socket being wired with 75° C insulated wire conductor, sized in accordance with Table 310-16 of the National Electric Code. K5 K6 ENERGIZATION OF ELECTRICAL EQUIPMENT IMPORTANT NOTE In addition to national and local electrical codes, many utilities have specific requirements for metering equipment. Always consult the serving utility for their specifications and requirements prior to ordering or installing Milbank meter mounting equipment. BEFORE ENERGIZING A. Give equipment a thorough visual examination to determine that: 1) No shipping or installation damage exists. 2) Proper clearances have been maintained. 3) All connections have been made. 4) Equipment is clean and dry. B. Make a thorough examination to: 1) Verify tightness of all bolted connections (see table below). 2) Manually operate all circuit breakers, switches, relays, etc. 3) Check rigidity of all mountings, bus bars and components. 4) Use test equipment to check continuity of circuitry and integrity of insulation. C. All switches and circuit breakers should be in the “off” position. D. Verify that manual meter bypass (if applicable) is in non-bypass position. E. Install cover and/or close doors. F. If installation is not being energized at this time, follow “after-energizing” steps listed below. These steps will secure the installation in case of accidental energization. WHEN ENERGIZING SECTION K ACCESSORIES & MISCELLANEOUS A. Use caution and follow established safety procedures: 1) Wear safety apparel. 2) Use safety equipment. 3) Take action to prevent injury to yourself and others in the event of failure of the installation. 4) Take action to prevent/decrease damage to property in the event of failure of the installation. 5) If you are unsure how to safely energize the installation, get someone who is knowledgeable to do it. AFTER ENERGIZING A. Secure the installation: 1) To prevent accidental contact with energized parts, cover all openings with approved filler devices. 2) To prevent unauthorized access, secure all covers and/or doors with approved security devices. 3) Attach/post information to advise others of potential hazards associated with the installation. RECOMMENDED TORQUE FOR GENERAL APPLICATIONS* JOINT DESCRIPTION NOMINAL SIZE SCREW NUT 10 10 10 12 12 1/4 1/4 5/16 5/16 3/8 1/2 BRASS STEEL STEEL STEEL STEEL STEEL STEEL STEEL STEEL STEEL STEEL Brass Nut or Extruded Hole CU or AL Busbar <1/8″ Steel Nut or EH; CU or AL Busbar >1/8″ Aluminum Extruded Hole Steel Nut or Extruded Hole Aluminum Extruded Hole Steel Nut or EH; CU or AL Busbar Aluminum Extruded Hole Steel Nut or EH; CU or AL Busbar Steel Nut Steel Nut HEAD TYPE TORQUE ( INCH LBS. ) ALL ALL ALL ALL ALL ALL ALL HEX HEX HEX HEX 20-25 in. lbs. 25-30 in. lbs 30-35 in. lbs 30-35 in. lbs 40-50 in. lbs. 40-50 in. lbs. 50-60 in. lbs. 60-70 in. lbs. 100-150 in. lbs. 150-200 in. lbs. 200-250 in. lbs. *Interior labels typically indicate the required torque for wire connectors and studs, and should be referenced first. EH: Extruded Hole CU: Copper AL: Aluminum K6 MATERIALS AND FINISHES K7 MATERIALS STEEL QUALITY The meter equipment listed in this catalog is made of galvanized steel (AISI* G90) to afford the best possible weather proofing. *American Iron and Steel Institute. STEEL SHEET 16 gauge, galvanized, sheet: 1 1/4 oz./ sq.ft. class zinc-coated. (AISI G90) 14 gauge, galvanized, sheet: 1 1/4 oz./ sq.ft. class zinc-coated. ALUMINUM EXTRUSION Wire-Terminals: Alloy; 6061-T6, Tin-plated for CU/AL wire. Bus Bar: Alloy; 6101-o & 6063-O ALUMINUM SHEET 3000 series aluminum sheet, H14, or 5052 series aluminum sheet, H32. Where applicable thicknesses range from .064 — .125 COPPER SHEET & BUS Electrolytic copper with tin plating in most applications. INSULATING MATERIALS • In most units, support bases for current-carrying components are molded from fiberglass reinforced high-strength, track resistant, thermoset polyester molding compounds. • Various sheet insulating materials, as appropriate for the application are utilized in the fabrication of flat, formed and punched component parts and barriers. FINISH PROCESS Light gray “state of the art” electrostatically applied powder paint offers a durable, non-fading finish. For further information concerning the chemical analysis of the weather resistant finish, please contact the factory. SECTION K METAL FASTENERS ACCESSORIES & MISCELLANEOUS • Clear or black safety shields and polarity barriers are molded from high-strength, track resistant, polycarbonate molding compounds. Zinc-coated with a chromate dip. RATING NEMA RATING Milbank meter sockets, CT cans and meter socket / breaker units have a type 3R rating. K7 K8 METER FORMS DIAGRAM A DIAGRAM B DIAGRAM C DIAGRAM D 1∅2W with 1 P.T. & 1 C.T. Single Stator Meter(2W1∅) - Form 3S 5T Socket, Test Switch #TS04-0101 1∅3W with 1 C.T. Single Stator Meter(2W1∅) - Form 3S 5T Socket, Test Switch #TS04-0101 1∅3W with 2 C.T.ʼs Single Stator Meter(3W1∅) - Form 4S 6T Socket, Test Switch #TS07-0105 1∅3W or 3W Network with 2 C.T.ʼs 2 Stator Meter - Form 5S 8T Socket, Test Switch #TS07-0105 DIAGRAM A DIAGRAM B DIAGRAM D (ALT.LOC.) (ALT.LOC.) P1 PN DIAGRAM C + C1 + C1 P1 PN C1 C1 + C1 P1 P2 + C2 + C2 C2 + C1 P1 P2 PN + C2 C2 C1 + P.T. + + + I LINE N I + LINE 2 N C.T. (BONDED) ACCESSORIES & MISCELLANEOUS LOAD LINE (BONDED) + I N(BONDED) 2 C.T. C.T. + LOAD + LINE + I N(BONDED) 2 C.T. + LOAD + C.T. DIAGRAM E DIAGRAM F DIAGRAM G DIAGRAM H 3∅3W “Δ” with 2 P.T.ʼs & 2 C.T.ʼs 2 Stator Meter - Form 5S 8T Socket, Test Switch #TS07-0105 3∅3W “Δ” with 2 C.T.ʼs 2 Stator Meter - Form 5S 8T Socket, Test Switch #TS07-0105 3∅4W “Y” with 3 C.T.ʼs 2 1⁄2 Stator Meter - Form 6S 13T Socket, Test Switch #TS10-0109 3∅4W “Y” with 2 P.T.ʼs & 3 C.T.ʼs 2 1⁄2 Stator Meter - Form 6S 13T Socket, Test Switch #TS10-0109 DIAGRAM E SECTION K + + + LOAD C.T. DIAGRAM G DIAGRAM F P1 P1 P3 P2 C+1 + C3 C3 C1 P2 C+1 P1 P3 P3 PN C+ DIAGRAM H C+ C C C+ C P1 P3 PN + PT PT PT + + + + 1 LINE 2 3 1 2 LINE 3 N + + C.T. + LOAD + C.T. + 1 LINE 2 3 C.T. + LOAD + C.T. DIAGRAM I DIAGRAM J 3∅4W “Y” or “Δ” with 3 C.T.ʼs “Y” 3 Stator Meter - Form 9S “Δ” 2 Stator Meter - Form 8S 13T Socket, Test Switch #TS10-0109 3∅4W “Y” with 3 P.T.ʼs & 3 C.T.ʼs 3 Stator Meter - Form 9S 13T Socket, Test Switch #TS10-0109 DIAGRAM I P1 P2 P3 PN + C + C C C + C C P1 P2 P3 PN C C+ + C.T. + C.T. LOAD + + C.T. 1 2 LINE 3 N(BONDED) C+ + + C + + + C.T. + (BONDED) + PT C.T. LOAD + + C.T. 1 2 LINE 3 N(BONDED) + + + + C.T. + C.T. LOAD + + C+ C C PREWIRING: If standard factory prewiring is required, refer to wiring diagrams on this page. Determine appropriate diagram and send a copy with order. If custom factory prewiring is required, specify on order. Be sure to include meter socket catalog number, test switch make and catalog number, meter form number and provide a copy of your wiring diagram. C+ C PT PT PT + + + + + C+ C DIAGRAM J + 1 2 LINE 3 N(BONDED) C+ + C3 C3 C1 + + + C.T. + C.T. + LOAD + C.T. K8 C.T. WATTHOUR METER FORMS—STANDARD FORMS TRANSFORMER RATED OR SELF-CONTAINED SC 2 and 3-WIRE FORMS 1S & 2S SC 2 and 3-WIRE FORMS 1S & 2S with BYPASS TR TR 2-WIRE FORM 3S 5th Term. 9 o'clock 2-WIRE FORM 3S with BYPASS TR 2-WIRE FORM 3S 5th Term.6 o'clock TR SC SC SC 2-WIRE FORM 3S with BYPASS 2 ELEMENT 3-WIRE NETWORK FORM 12S 5th TERM. 9 o'clock 2 ELEMENT 3-WIRE NETWORK FORM 12S with BYPASS 5th Term. 9 o'clock 2 ELEMENT 3-WIRE NETWORK FORM 12S 5th TERM. 6 o'clock TR TR SC 3-WIRE FORM 4S 3-WIRE FORM 4S WITH BYPASS TR TR SC SC TR 2 ELEMENT 2∅3W, 2∅4W, 3∅3W FORM 5S 2 ELEMENT 2∅3W, 2∅4W, 3∅3W FORM 5S with BYPASS 2 ELEMENT 2∅3W, 2∅4W, 3∅3W FORM 13S 2 or 3 ELEMENT 2∅3W, 2∅4W, 3∅3W FORM 13S with BYPASS 2 or 3 ELEMENT 3∅4W Y or ∆ Y FORM 9S ∆ FORM 8S TR TR TR 2 ELEMENT 3∅4W Y FORM 6S 2 ELEMENT 3∅4W Y FORM 6S with BYPASS 2 or 3 ELEMENT 3∅4W Y or ∆ FORMS 14S & 15S with BYPASS SC 2 ELEMENT 3-WIRE NETWORK FORM 12S with BYPASS 5th Term. 6 o'clock TR 2 ELEMENT 3∅4W Y or ∆ Y FORM 7S ∆ FORM 24S with BYPASS ACCESSORIES & MISCELLANEOUS 2 or 3 ELEMENT 3∅4W Y or ∆ Y FORM 14S ∆ FORM 15S SC K9 SECTION K TR = TRANSFORMER RATED SC = SELF CONTAINED 2 or 3 ELEMENT 3∅4W Y or ∆ FORMS 8S & 9S with BYPASS Utility requirements for this equipment may vary. Always consult the serving utility for their requirements before ordering or installing equipment in this catalog. K9 K10 STANDARD NEMA CONFIGURATIONS 2 POLE—3 WIRE—GROUNDING RECEPTACLES STRAIGHT BLADE WIRING DEVICES VOLTS CODE 15 AMPS 20 AMPS G 125V 5 30 AMPS TWIST-LOCK WIRING DEVICES 50 AMPS G G G W 30 AMPS W W G G L5-20R L5-30R G W 5-15R 5-20R G 5-30R 5-50R G G L5-15R G G G G 6-20R G G W W 6-30R 6-50R G L6-15R G 7-15R W 7-20R 7-30R L6-20R L6-30R W W W G G G 7 Y Y Y 6-15R X X X 250V 6 277 VAC 20 AMPS W W W 15 AMPS W 7-50R L7-15R L7-20R L7-30R 3 POLE—3 WIRE—SPECIAL APPLICATIONS STRAIGHT BLADE WIRING DEVICES SECTION K ACCESSORIES & MISCELLANEOUS VOLTS CODE 125V 10 250V 20 AMPS 30 AMPS 50 AMPS W W TWIST-LOCK 20 AMPS 30 AMPS X X W Y W W X Y X 10-20R 10-30R X Y 10-50R Y L10-20R Y L10-30R 3 POLE—4 WIRE—GROUNDING STRAIGHT BLADE WIRING DEVICES VOLTS CODE 125V 14 250V 15 AMPS 20 AMPS G Y 30 AMPS Y 50 AMPS G G X TWIST-LOCK X W W Y X Y 14-20R 30 AMPS X X G X G W G W W W 14-15R 20 AMPS 14-30R 14-50R Y L14-20R Y L14-30R 2 POLE—3 WIRE—GROUNDING—NEMA TRAILER STRAIGHT BLADE VOLTS CODE 30 AMPS G 125V TT W TT-30R Utility requirements for this equipment may vary. Always consult the serving utility for their requirements before ordering or installing equipment in this catalog. K10 ADDITIONAL MILBANK PRODUCTS K11 Other quality products available from Milbank COMMERCIAL ENCLOSURES 2007 PRICE LIST Effective June 26, 2006 Supercedes and cancels all previous Milbank lists. All prices listed within are subject to change without notice. MILBANK MFG. CO.– ENCLOSURE GROUP 1601 South St. Louis Street Concordia, MO 64020 Tel: 660-463-0805 Fax: 660-463-7950 Toll Free: 1-877-483-5314 www.milbankmfg.com Contact your local distributor or go to www.milbankmfg.com to find additional product literature. K11 SECTION K Air Conditioner Disconnects Hot Tub Disconnects RV/Mobile Home Power Outlets Terminal Boxes Temporary Power Outlets Commercial Pedestals Commercial Enclosures CT Enclosures Circuit Breakers Enclosed Circuit Breakers Safety Switches Test Switches ACCESSORIES & MISCELLANEOUS In addition to your local utility’s meter mounting equipment, Milbank also manufactures supporting products, such as... SECTION L ALPHA-NUMERIC INDEX L1 ALPHA-NUMERIC INDEX 6003 .................................K1 708785-MO........................I8 CT303611-HC ..................F2 K5400-520GR....................I2 MPRV-100-78 ..................G1 6116 .................................K1 A3800 ...............................A1 CT303614-SC...................F2 K5400-620 .......................G9 MPRV-100-MB-78............G1 020-147-00-00-0 ............G10 A7514 ...............................K1 CT304811-HC ..................F2 K5400-620 .........................I2 MPRV-100-MBLC-80 .......G3 020-148-00-00-0 ............G10 A7515 ...............................K1 CT363611-SC...................F2 K5400-620GB ....................I2 MPRV-200-MBLC-80 .......G3 020-509-01-00-0 ............G10 A7516 ...............................K1 CT364211-SC...................F2 K5400-620GR ..................G9 MPRV-503020GR-78.......G1 105J..................................E2 A7517 ...............................K1 CT364811-HC ..................F2 K5400-BLANK................H17 MPRV-50-78 ....................G1 114TB...............................D1 A7518 ...............................K1 CT364811-SC...................F2 K5400-BRIDGE..............H17 MPRV-BLANK-78 ............G1 115TB...............................D1 A7551 ...............................K1 CT364814-HC ..................F2 K5400-BRIDGE-1POS..G5-9 MPRV-BLANK-78-R-5T ...G1 116TB...............................D1 A8110 ...............................K1 CT364814-SC...................F2 K5400-BRIDGE-2POS..G5-9 MR-2 ..............................H18 124TB...............................D1 A8111 ...............................K1 CT424211-SC...................F2 K5400-GB ......................H17 MR-2.................................K2 125TB...............................D1 A8112 ...............................K1 CT484811-HC ..................F2 K5400-NEUTRAL...........H17 MR-2SS............................K2 127TB...............................D1 A9064 ...............................K1 CT484811-SC...................F2 K5400-TT30 ......G5-9, H2-10 MR-4.................................K2 214MTB............................D2 AP-2300-03 ......................B1 CT484814-HC ..................F2 K5400-TT30 ...................H17 MS24-TB ........................D16 214MTB/22.......................D3 AP-2300-04 ......................B1 ED42B100......................D14 K5400-TT30GB...........H2-10 MS27-TB ........................D16 214MTB-48 ......................D4 BC214 ............................D12 ED43B100......................D14 K5410.............................H15 P-10GR ..........................H16 214MTB-P ........................D5 BC234 ............................D12 FXD62B200....................D14 K5411.............................H13 P-13................................H16 214MTB-P48 ....................D5 BC318 ............................D12 FXD63B200....................D14 K5412.............................H13 P-54................................H16 215MTB............................D2 BC338 ............................D12 K1350 .............................B15 K5413.............................H13 PB-011 ...........................D11 215MTB-48 ......................D4 BC418 ............................D12 K1350 ...............................K1 K5415 ...........................G5-7 PB-012 ...........................D11 215MTB-P ........................D5 BC438 ............................D12 K1350L .............................K1 K5415.............................H15 PB-014 ...........................D11 215MTB-P48 ....................D5 BC518 ............................D12 K1539 .............................B15 K5421.............................H15 PB-014-NK .....................D11 217MTB............................D2 BC538 ............................D12 K1539 ...............................K1 K5421.............................H15 PB-018 ...........................D11 217MTB/22.......................D3 BC618 ............................D12 K1540 .............................B15 K5747 ...............................F3 PB-018-NK .....................D11 217MTB-48 ......................D4 BC638 ............................D12 K1540 ...............................K1 K5757 ...............................F3 PB-032 ...........................D11 217MTB-P ........................D5 CL200.............................H16 K1540L .............................K1 K5T ...............................G5-7 PB-034 ...........................D11 217MTB-P48 ....................D5 CP-16PDMNT-CALT ........E2 K1541 .............................B15 K5T...................................K2 PB-034-NK .....................D11 224MTB............................D6 CP-21 ...............................K1 K1541 ...............................K1 K8180 ...............................K2 PB-038 ...........................D11 224MTB/22.......................D7 CP-24PDMNT-CALT ........E2 K3082 ...............................K1 KK3388.............................F7 PF-BL.............................G11 224MTB-P ........................D9 CP3B11110A22SL1 .........E5 K3083 ...............................K1 KK3388-BLK-FL ...............F7 PF-KR ............................G11 224MTB-P48 ....................D9 CP3B11115A22................E4 K3441 ...............................K1 M400-APS........................C5 PT223.............................D16 225MTB............................D6 CP3B11115A42................E4 K3442 ...............................K1 M400-APS-BS..................C5 PT224.............................D16 225MTB-P ........................D9 CP3B111IRASP ...............E7 K3450 ...........................G5-7 M400-PAR........................C4 PT263.............................D16 225MTB-P48 ....................D9 CP3B111IRASS ...............E7 K3865 ...............................E2 M400-PAR-UG .................C4 PT264.............................D16 227MTB............................D6 CP3B12110A22SL1 .........E5 K3865 ...............................K2 M400-UG-APS-F..............C6 PT323.............................D16 227MTB/22.......................D7 CP3B12119A22................E4 K3866 ...............................K2 M400-UG-APS-F-BS........C6 PT324.............................D16 227MTB-125 ..................D14 CP3B1411JB22................E6 K4709-02........................H14 M400-UG-APS-LC ...........C6 PT363.............................D16 227MTB-150 ..................D14 CP3B14120B22................E6 K4709-WS......................H14 M400-UG-APS-LC-BS .....C6 PT364.............................D16 227MTB-175 ..................D14 CP3B51110A22SL1 .........E5 K4722 ...............................F3 M400-UG-APS-P..............C6 Q115 ..................................I8 227MTB-48 ......................D8 CP3B51115A22................E4 K4729 ...............................F3 M401-UG..........................C7 Q120 ..............................H18 227MTB-P ........................D9 CP3B511IRASP ...............E7 K4793 ...............................F3 M401-UG-BS....................C7 Q120 ..................................I8 227MTB-P48 ....................D9 CP3B52110A22SL ...........E5 K4794 ...............................F3 M404-UG-LC....................C8 Q130 ..............................H18 243210-LC3R-SP .............F1 CP3B52119A22................E4 K4795 ...............................F3 M404-UG-LC-BS..............C8 Q130 ..................................I8 323610-LC3R-SP .............F1 CP3B5411JB22................E6 K4796 ...............................F3 M5-144 .............................K2 Q220 ..................................I8 363016-CT3R ...................F1 CP3B8411JB22................E6 K4797 ...............................F3 MCP .................................K1 Q250 ..............................H18 363612-CT3R-SP .............F1 CP3B84120B22................E6 K4798 ...............................F3 MN1020-TVB ....................J1 Q250 ..................................I8 364812-CT3R-SP2 ...........F1 CP3B-AUX-1200 ............H11 K4800-01........................H16 MN1100 ............................J1 QJ22B200H....................D14 403456-SC.....................G11 CP-ABK5/8 .......................E2 K4903 ...............................F3 MN1100-NG......................J1 QJ23B200 ......................D14 403457-SC.....................G11 CP-PE-HOA-3POS...........E2 K4904 ...............................F3 MN-1100-TV .....................J1 QJH23B200L..................D14 5T8K2...............................K2 CP-TC24H........................E2 K5035 ...........................G5-7 MN2200 ............................J1 RBK-1 ............................G10 701776-MO ....................H17 CP-TC7D..........................E2 K5039 ...........................G5-7 MN900 ..............................J1 S8324 ...............................K1 701776-MO........................I8 CP-TCWIRE .....................E2 K5193 ...........................G5-7 MN900-B...........................J1 TB100-47 .......................D16 703997-MO........................I8 CT203611-HC ..................F2 K5194 ...........................G5-7 MPAP-100-78 ..................G2 TB100-5 .........................D16 704995-MO........................I8 CT242411-SC...................F2 K5400-1450 ......G5-9, H2-10 MPAP-100-MB-78............G2 TB200-47 .......................D16 706761-MO........................I8 CT243011-HC ..................F2 K5400-1450....................H17 MPAP-200-20GR-78........G2 TB200-LL .......................D16 707915-MO........................I8 CT243011-SC...................F2 K5400-1450 .......................I2 MPAP-200-78 ..................G2 TB-BARR .......................D16 708080-MO ....................H17 CT24329-SC.....................F2 K5400-1450GB ................G9 MPAP-200-MB-78............G2 TS04-0049........................F8 708080-MO........................I8 CT243611-HC ..................F2 K5400-1450GB ..................I2 MPAP-BLANK-78.............G2 TS04-0101........................F8 708676-MO ....................H17 CT243611-SC...................F2 K5400-520 ......................I2-7 MPAP-BLANK-78-R.........G2 TS04-0104........................F8 708777-MO........................I8 CT244811-HC ..................F2 K5400-520GB .............H2-10 MPAPD-BLANK-78 ..........G2 TS04-0105........................F8 708784-MO ....................H18 CT244811-SC...................F2 K5400-520GR ...G5-9, H2-10 MPAPD-BLANK-78R .......G2 TS04-0106........................F8 708784-MO........................I8 CT303011-SC...................F2 K5400-520GR ................H17 MPRV-100-20GR-78........G1 TS10-0016........................F8 L1 ALPHA-NUMERIC INDEX U4909-O ............................I2 U5268-XTL-150................C2 UQFB-100-X1...................K4 U2855-X .........................B15 U4909-O-11GR..................I2 U5268-XTL-150-KK..........C2 UQFB-125 ........................K4 TS10-0111........................F8 U2856-X .........................B15 U4909-O-55GBGR ............I2 U5268-XTL-200................C2 UQFB-125-X1...................K4 TS10-0112........................F8 U2862-X .........................B15 U4969-KO ........................B5 U5268-XTL-200-KK..........C2 UQFB-150 ........................K4 U1060-RL .........................B3 U2863-X .........................B15 U5000-XL .........................H2 U5269-XTL-200................C2 UQFB-150-X1...................K4 U1079-R .........................B10 U2864-X .........................B15 U5000-XL...........................I4 U5300-O.........................H10 UQFB-175 ........................K4 U1129-O-K3L-K2L..........B10 U2865-X .........................B15 U5000-XL-332..................H2 U5300-O-41 ...................H10 UQFB-175-X1...................K4 U1211-RXL.......................B7 U2866-X .........................B15 U5000-XL-41....................H2 U5300-O-55 ...................H10 UQFB-200 ........................K4 U1252-X-K1....................B13 U3251-O-200-CB .............C6 U5000-XL-55....................H2 U5300-O-552GR ............H10 UQFB-200-X1...................K4 U1253-X-K3....................B13 U3320-R ...........................F4 U5000-XL-75....................H2 U5300-O-75 ...................H10 UQFBH-100......................K4 U1254-X-K3....................B13 U3322-R ...........................F4 U5000-XL-75GB...............H2 U5310-O.........................H10 UQFBH-125......................K4 U1255-X-K4....................B13 U3328-RXL.......................B4 U5001-RL-01 .....................I5 U5320-O.........................H10 UQFBH-150......................K4 U1256-X-K4....................B13 U3340-O ...........................F4 U5056-O.........................B10 U5330-O.........................H10 UQFBH-175......................K4 U1431-R .........................B10 U3342-O ...........................F4 U5059-X-2/200.................C4 U5706-O-200S.................G9 UQFBH-200......................K4 U1432-O.........................B10 U3462-O.........................D13 U5100-XL .........................H4 U5706-O-200S-KK...........G9 UQFP-100 ......................H11 U1527-O...........................B3 U3463-O.........................D13 U5100-XL...........................I7 U5707-O-200S.................G9 UQFP-100 ........................K3 U1681-RL .........................B2 U3464-O.........................D13 U5100-XL-41....................H4 U5759-X-2/200.................C4 UQFP-125 ......................H11 U1797-O-K3L-K2L..........B10 U3465-O.........................D13 U5100-XL-55....................H4 U7021-RL-TG..................`B3 UQFP-125 ........................K3 U1819-X .........................B10 U3466-O.........................D13 U5100-XL-552GR ............H4 U7040-XL-TG ...................B3 UQFP-150 ......................H11 U1980-O...........................B3 U3504-XL .........................B9 U5100-XL-75....................H4 U7043-XL-TG ...................B3 UQFP-150 ........................K3 U2120-X .........................B11 U3507-XL .........................B9 U5100-XL-75GB...............H4 U7422-RXL.......................B6 UQFP-175 ......................H11 U214MTB .........................D2 U3514-XL .........................B9 U5101-XL .........................H4 U7423-RXL.......................B6 UQFP-175 ........................K3 U214MTB/22 ....................D3 U3517-XL .........................B9 U5101-XL...........................I7 U7487-O...........................B2 UQFP-200 ......................H11 U214MTB-48....................D4 U3522-XL-K1..................B12 U5136-O ..........................G7 U7487-RL .........................B2 UQFP-200 ........................K3 U214MTBL .....................D10 U3523-XL-K1..................B12 U5136-O-100S.................G7 U7490-O...........................B2 UQFP-225 ......................H11 U214MTB-P .....................D5 U3524-XL-K2..................B12 U5136-O-200S.................G7 U7490-RL .........................B2 UQFPG-100 .....................K3 U214MTB-P48 .................D5 U3525-XL-K2..................B12 U5137-O ..........................G7 U7573-RL .........................B6 UQFPG-125 .....................K3 U214MTBPL...................D10 U3532-X-K1....................B13 U5137-O-100S.................G7 U8032-XL .......................B12 UQFPG-150 .....................K3 U215MTB .........................D2 U3533-X-K3....................B13 U5137-O-200S.................G7 U8033-XL .......................B12 UQFPG-175 .....................K3 U215MTB-48....................D4 U3548-X .........................B11 U5138-O ..........................G7 U8034-XL .......................B12 UQFPG-200 .....................K3 U215MTB-P .....................D5 U3555-R ...........................F4 U5138-O-200S.................G7 U8035-XL .......................B12 UQFPH-100 ...................H11 U215MTB-P48 .................D5 U3565-O ...........................F4 U5168-100-KK-5T ............C2 U8036-XL .......................B12 UQFPH-125 ...................H11 U217MTB .........................D2 U3574-RL-200..................C1 U5168-150-KK-5T ............C2 U8100-RL .........................B6 UQFPH-150 ...................H11 U217MTB/22 ....................D3 U3577-RL-200..................C1 U5168-XTL-100................C2 U9319-XL .........................B7 UQFPH-175 ...................H11 U217MTB-48....................D4 U3587-O-200 ...................C1 U5168-XTL-100-KK..........C2 U9320-RXL.......................B6 UQFPH-200 ...................H11 U217MTBL .....................D10 U3800...............................A1 U5168-XTL-150................C2 U9550-RRL ......................B8 UQFPH-225 ...................H11 U217MTB-P .....................D5 U3801...............................A1 U5168-XTL-150-KK..........C2 U9551-RXL.......................B8 UQFPH-M-100 .................K3 U217MTB-P48 .................D5 U3830...............................A1 U5168-XTL-200................C2 U9700-RRL ......................B8 UQFPH-M-125 .................K3 U217MTBPL...................D10 U3860...............................A1 U5168-XTL-200-KK..........C2 U9701-RXL.......................B8 UQFPH-M-150 .................K3 U224MTB .........................D6 U3822-20GR ....................A2 U5169-XTL-100................C2 UC1290-XL.......................F5 UQFPH-M-175 .................K3 U224MTB/22 ....................D7 U3852-XL .........................B7 U5169-XTL-150................C2 UC1291-RL.......................F5 UQFPH-M-200 .................K3 U224MTB-48....................D8 U3854-O-200 ...................C1 U5169-XTL-200................C2 UC1299-XL.......................F5 UQFP-M-100 ....................K3 U224MTBL .....................D10 U4015-KO ........................B5 U5200-XL .........................H5 UC1300-RL.......................F5 UQFP-M-125 ....................K3 U224MTB-P .....................D9 U4015-O...........................B4 U5200-XL-332..................H5 UC3423-XL.......................F6 UQFP-M-150 ....................K3 U224MTB-P48 .................D9 U4031-O-2/200 ................C4 U5200-XL-41....................H5 UC3425-XL.......................F6 UQFP-M-175 ....................K3 U224MTBPL...................D10 U4517-DL-M4...................B4 U5200-XL-75....................H5 UC3426-XL.......................F6 UQFP-M-200 ....................K3 U225MTB .........................D6 U4517-KO ........................B5 U5200-XL-75GB...............H5 UC3428-XL.......................F6 USE-AP-200-MB ..............C3 U225MTBL .....................D14 U4518-KO ........................B5 U5210-XL .........................H5 UC3433-XL.......................F6 USE-AP-200-ML ..............C3 U227MTB .........................D6 U4518-O-W ......................B4 U5220-XL .........................H5 UC3434-XL.......................F6 Z020-148-00-00-0..............I8 U227MTB/22 ....................D7 U4518-XL-W.....................B4 U5220-XL-41....................H5 UC3435-XL.......................F6 Z020-509-11-00-0..............I8 U227MTB-125................D14 U4540-XL .......................H12 U5220-XL-75....................H5 UC3436-XL.......................F6 Z818052-SC...................H18 U227MTB-150................D14 U4542-XL .......................H12 U5230-XL .........................H5 UC3438-XL.......................F6 Z818480-SC...................H18 U227MTB-175................D14 U4544-XL .......................H12 U5240-O ..........................G5 UC7233-XL.......................F5 Z915141-AC...................H18 U227MTB-48....................D8 U4546-XL .......................H12 U5240-O-100S.................G5 UC7235-XL.......................F5 Z917602-AC...................H18 U227MTBL .....................D10 U4548-RXL ....................H12 U5240-O-200S.................G5 UC7237-XL.......................F5 Z918447-SC...................H18 U227MTB-P .....................D9 U4549-RXL ....................H12 U5241-O ..........................G5 UC7461-YL-TGE-DES......F6 Z918449-SC...................H18 U227MTB-P48 .................D9 U4881-O-50GB ................A2 U5241-O-100S.................G5 UC7544-RL.......................F5 Z918466-AC...................H18 U227MTBPL...................D10 U4881-O-60GB ................A2 U5241-O-200S.................G5 UC7545-RL.......................F5 U2594-X .........................B11 U4908-O ............................I2 U5242-O-200S.................G5 UC7582-RL.......................F5 U2852-X .........................B15 U4908-O-11GR..................I2 U5243-O ..........................G5 UC7636-YL-TGE-DES......F6 U2853-X .........................B15 U4908-O-55GBGR ............I2 U5252-O ..........................G5 UQFB-100 ........................K4 L2 SECTION L U2854-X .........................B15 TS10-0110........................F8 ALPHA-NUMERIC INDEX TS10-0109........................F8 L2 L3 EUSERC INDEX EUSERC INDEX SECTION L EUSERC INDEX Milbank Catalog EUSERC Number Drawing Number U3574-RL-200 U3577-RL-200 U3584-O-200 U3587-O-200 U4015-O UF4015-KO U3548-X M400-UG-APS-F M400-UG-APS-F-BS M400-UG-APS-P M400-UG-APS-LC M400-UG-APS-LC-BS U3251-O-200-CB M401-UG M401-UG-BS M404-UG-LC M404-UG-LC-BS 114TB 115TB 117TB 124TB 125TB 127TB 214MTB 215MTB 217MTB U214MTB U215MTB U217MTB 214MTB/22 217MTB/22 U214MTB/22 U217MTB/22 214MTB-48 215MTB-48 217MTB-48 U214MTB-48 U215MTB-48 U217MTB-48 214MTB-P 215MTB-P 217MTB-P U214MTB-P U215MTB-P U217MTB-P 214MTB-P48 215MTB-P48 217MTB-P48 U214MTB-P48 U215MTB-P48 U217MTB-P48 224MTB 225MTB 227MTB U224MTB U225MTB U227MTB 224MTB/22 227MTB/22 U224MTB/22 301 301 301 301 301A 301A 302B 302A 302 302A 302A 302 302 302A 302 302A 302 304, 311 304, 311 304, 311 305, 311 305, 311 305, 311 305A, 311 305A, 311 305A, 311 305A, 311 305A, 311 305A, 311 305A, 311 305A, 311 305A, 311 305A, 311 305A, 311 305A, 311 305A, 311 305A, 311 305A, 311 305A, 311 305A, 311 305A, 311 305A, 311 305A, 311 305A, 311 305A, 311 305A, 311 305A, 311 305A, 311 305A, 311 305A, 311 305A, 311 305A, 311 305A, 311 305A, 311 305A, 311 305A, 311 305A, 311 305A, 311 305A, 311 305A, 311 Catalog Page C1 C1 C1 C1 B4 B5 B11 C6 C6 C6 C6 C6 C6 C7 C7 C8 C8 D1 D1 D1 D1 D1 D1 D2 D2 D2 D2 D2 D2 D3 D3 D3 D3 D4 D4 D4 D4 D4 D4 D5 D5 D5 D5 D5 D5 D5 D5 D5 D5 D5 D5 D6 D6 D6 D6 D6 D6 D7 D7 D7 Milbank Catalog EUSERC Number Drawing Number U227MTB/22 227MTB-48 U224MTB-48 U227MTB-48 224MTB-P 225MTB-P 227MTB-P U224MTB-P U227MTB-P 224MTB-P48 225MTB-P48 227MTB-P48 U224MTB-P48 U227MTB-P48 U214MTBL U214MTBPL U217MTBL U217MTBPL U224MTBL U224MTBPL U227MTBL U227MTBPL PB-011 PB-012 PB-014 PB-014-NK PB-018 PB-018-NK PB-032 PB-034 PB-034-NK PB-038 U3320-R U3322-R U3555-R U3340-O U3342-O U3565-O CT244811-SC CT364811-SC CT364814-SC CT484811-SC CT244811-HC CT304811-HC CT364811-HC CT484811-HC CT484814-HC K4903 K4904 K4722 K4729 K4797 K4798 UC3435-XL UC3436-XL UC3438-XL UC3433-XL UC3434-XL L3 305A, 311 305A, 311 305A, 311 305A, 311 305A, 311 305A, 311 305A, 311 305A, 311 305A, 311 305A, 311 305A, 311 305A, 311 305A, 311 305A, 311 305A, 311 305A, 311 305A, 311 305A, 311 305A, 311 305A, 311 305A, 311 305A, 311 343A 343A 343 343 343 343 343A 343 343 343 313 Single Phase Only 313 313 314 Single Phase Only 314 314 316, 317 316, 317, 318 316, 317, 318 316, 317 316, 317 316, 317 316, 317, 318 316, 317, 318 316, 317, 318 328B 329B 329B 328B 328A 329A 339 339 339 339 339 Catalog Page D7 D8 D8 D8 D9 D9 D9 D9 D9 D9 D9 D9 D9 D9 D10 D10 D10 D10 D10 D10 D10 D10 D11 D11 D11 D11 D11 D11 D11 D11 D11 D11 F4 F4 F4 F4 F4 F4 F2 F2 F2 F2 F2 F2 F2 F2 F2 F3 F3 F3 F3 F3 F3 F6 F6 F6 F6 F6 Meter Mounting Equipment & More! Commercial Electrical Enclosures Residential & Commercial Metering Commercial Meter Pedestals Disconnect Devices Current Transformer Enclosures RV/MH Pedestals Temporary Power Outlets Circuit Breakers Enclosed Circuit Breakers Safety Switches Test Switches REPRESENTED BY: MILBANK MFG. CO. PO Box 419028 Kansas City, MO 64141-0028 Tel: 816-483-5314 Fax: 816-483-6357 Toll Free: 877-483-5314 www.milbankmfg.com www.milbankmfg.com WRC 4/08 (5K)
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.6 Linearized : Yes XMP Toolkit : Adobe XMP Core 4.0-c316 44.253921, Sun Oct 01 2006 17:08:23 Trapped : False GTS PDFX Version : PDF/X-1:2001 GTS PDFX Conformance : PDF/X-1a:2001 Producer : Acrobat Distiller 8.1.0 (Macintosh) Create Date : 2009:01:06 21:01:08-06:00 Modify Date : 2009:01:06 21:08:45-06:00 Creator Tool : QuarkXPress 7.2 Metadata Date : 2009:01:06 21:08:45-06:00 Format : application/pdf Creator : Kim Tappan Title : WRC_4-08:UNY 1/03 Document ID : uuid:283545b8-613d-4b69-996a-25123c664ef8 Instance ID : uuid:4a14975b-c816-4556-a86c-7084d9e9b46f Page Count : 128 Author : Kim TappanEXIF Metadata provided by EXIF.tools