AC Controller Lid Instructions Rev 3_04_09 Geotech SS Geosub And Quick Start Guide
User Manual: Pdf Geotech SS Geosub and AC Controller Quick Start Guide
Open the PDF directly: View PDF
.
Page Count: 1
| Download | |
| Open PDF In Browser | View PDF |
Rev. 3/04/2009 Part # 11200828 Geotech Environmental Equipment, Inc 2650 East 40th Avenue Denver, Colorado 80205 1-800-833 -7958 website: www.geotechenv.com AC CONTROLLER INSTRUCTIONS AND PUMP MAINTENANCE DIS-ASSEMBLY AND CLEANING BASIC OPERATION • • • • • • From main menu: • Press • Wait for pump start up to finish. • • • Verify main power switch is in OFF position. Plug power cord into controller. Plug power cord into AC supply outlet. Switch main power to ON position. Wait for initialization sequence to complete. UP DOWN • START PUMP LOAD WELL Pump water at desired pump speed. • Press Top Cap 21200076 • • PUMPING WELL #nn PUMP START UP PUMPING WELL #nn nnn DR ON nn OR PUMPING WELL #nn nnn DR OFF nn • to stop pump and return to main menu. • • • • • • SETTING DRY RUN NOTE: Set point must be above 100 for Dry Run protection to be activated • Press • • to start the pump at default settings. or to adjust pump Press speed to achieve desired flow rate. Disconnect pump cable from controller. Unscrew outer housing (No tools needed). to toggle Dry Run ON and OFF FOR MAINTENANCE AND SERVICE PLEASE CALL GEOTECH DIRECTLY AT 1-800-833-7958 NOTE: LOADING WELL #0 WILL LOAD DEFAULT START UP CONFIGURATION Note: A very small amount of inert grease may be used to help lubricate O-ring seals. Twist the motor assembly and inner housing assembly 180 degrees, twisting the wires to create more room. Push the inner housing over the top cap, be careful not to damage O-rings. Install the outer housing making sure the threads do not bind. • • • • Remove inner housing by pulling apart, slightly twisting while pulling may help. The control module may become disconnected from the motor lead while pulling apart, this is normal. Remove motor assembly from inner housing by pulling apart, slightly twisting while pulling may help. Inspect motor assembly, impeller, and control module for damage or wear. Inspect internal wires for cuts or breaks, mak ing sure all wires have insulation covering them. Inspect all o-rings for nicks, cuts, brittleness Decontaminate outer and inner housing. Decontaminate the motor assembly and control module. Decontaminate top cap and hose barb Clean all threads thoroughly to make sure nothing will bind them. Insert motor assembly back into inner housing, be careful not to damage O-rings. Connect control module wires back onto motor lead. Outer Housing Weldment 51200186 Inner Housing 21200072 Intake Motor Assembly 51200089 Control Module 51200083 Impeller PARTS 1. AC CONTROLLER 300 WATT 120 volts 2. AC CONTROLLER 300 WATT 230 volts 3. FUSE 4. MANUAL 5. GOLD CONNECTORS & HEAT SHRINK 6. O-RING KIT 7. CHECK VALVE PART # 81200031 81200032 11200746 11200813 11200754 51200088 81200033
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.3 Linearized : No Page Count : 1 Producer : PrimoPDF Create Date : 2009:03:05 09:43:23 Modify Date : 2009:03:05 09:43:23 Title : AC Controller lid instructions rev 3_04_09.indd Creator : PrimoPDF http://www.primopdf.com/ Author : RickEXIF Metadata provided by EXIF.tools