[MNC 300] FCC Ver
[Mnc-300] Fcc Ver [MNC-300]_FCC_ver [MNC-300]_FCC_ver CertsReports 550413 ProductFiles assets.mhint
2016-04-12
: Pdf [Mnc-300] Fcc Ver [MNC-300]_FCC_ver CertsReports 550406 ProductFiles
Open the PDF directly: View PDF .
Page Count: 27
Download | |
Open PDF In Browser | View PDF |
Certification No. : LR500110806C Verification With The 47 CFR, Part2 and Part15 Of FCC Requirement Hereby certifies that Type of Product: Dome Network Camera (Class A digital devices) Model No.: MNC-300 Manufactures and address MicroWeb Co., Ltd. 909 Kranz Techno Bldg., 5442-1 Sangdaewon-dong, Jungwon-gu, Seongnam-si, Gyeonggi-do, 462-729 Korea. This document is the proof that above product, system, and also relates OEM models are complying with FCC requirement. We, LTA Co., Ltd is the accredited EMC laboratory for NVLAP(US), RRL(KOREA). We certify that the above products had performed test on our laboratory and it was confirmed to comply with FCC requirement. These products might be marketed at the US accordance to DoC of FCC Rule based on the standard 47CFR Part 2 and 15. The test was performed accordance to the procedures from ANSI C63.4-2003. Test data and results are issue on the EMC test report No. as follows. Reference Endorsed Test Report No. is LR500110806C Date: June 13, 2008 Dong –Min JUNG, Technical Manager LTA Co., Ltd. NVLAP LAB Code.: 200723-0 Certification No. : LR500110806C TEST REPORT This laboratory is accredited by Radio Research Laboratory and National Voluntary Laboratory Accreditation Program. The tests reported herein have been performed in accordance with its terms of accreditation. Test Report No. Issue Date Applied Standard Trade Name Category : : : : : LR500110806C June 13, 2008 FCC Part 15, Subpart B MicroWeb Co., Ltd Dome Network Camera (Class A digital devices) Model Name Serial Number : MNC-300 : Identification This test result only responds to the tested sample. It is not allowed to copy this report even partly without the allowance of the test laboratory. This report must not be used by the applicant to claim product endorsement by NVLAP or any agency of the U.S. Government. Copyright © 2008, LTA CO., LTD. Page 1 of 26 Certification No. : LR500110806C TABLE OF CONTENTS ★★★★★★★★★★★★ Text Contents Page ---------------------------------------------------------------------------------------------------------- 2 LTA Certification ----------------------------------------------------------------------------------------------- 3 General Information ----------------------------------------------------------------------------------------------- 6 Brief Information --------------------------------------------------------------------------------------------------- 7 Test site description -------------------------------------------------------------------------------------------------- 10 Test Procedure ------------------------------------------------------------------------------------------------------ 11 List of test equipment used for the test ----------------------------------------------------------------------- 13 --------------------------------------------------------------------------- 14 ------------------------------------------------------------------------- 15 Conclusions --------------------------------------------------------------------------------------------------------- 17 Photograph of the measurements ------------------------------------------------------------------------------- 18 ------------------------------------------------------------------------------------------ 20 Radiated disturbance measurement Result & Graph Conducted disturbance measurement Result & Graph Photograph of the EUT ★★★★★★★★★★★★ Copyright © 2008, LTA CO., LTD. Page 2 of 26 Certification No. : LR500110806C LTA Certification Client / Factory Company name : MicroWeb Co., Ltd. Address : 909 Kranz Techno Bldg., 5442-1 Sangdaewon-dong, Jungwon-gu, Seongnam-si, Gyeonggi-do, 462-729 Korea. Telephone / Facsimile : +82-31-735-7200 / +82-31-735-7600 Equipment Under Test (EUT) Trade name : MicroWeb Co., Ltd. Category : Dome Network Camera (Class A digital devices) Brand : Webview Model name : MNC-300 Additional Model name : - Serial number : Identification Date of receipt : May 19, 2008 EUT condition : Pre-production, not damaged Interface port : LAN, MIC, IR, POWER, BNC Power Source : INPUT : 100-240v, 50-60Hz, 1.0A OUTPUT : 12V, 2.5A Test memory Size : - Operating mode : Web camera + Ping mode Crystal/Oscillator(s) : Main : 14.318180 MHz, 28.750BMHz, 2.048BMHz, 10AMHz, 25MHz Sub : 28.375MHz, 27 MHz *** To be continued next page*** Copyright © 2008, LTA CO., LTD. Page 3 of 26 Certification No. : LR500110806C LTA Certification-cont.Model Specification Test Performed Test started & completed : May 19 ~ 23, 2008 Location : LTA Co., Ltd. Test Specification Purpose of the test : Compliance test to the following standard Applied standard : FCC Part 15, Subpart B Classification : Class A Deviations from Standard Test Method : N/A *** To be continued next page *** Copyright © 2008, LTA CO., LTD. Page 4 of 26 Certification No. : LR500110806C LTA Certification-cont.Test Results Measurement Results* Test method Radiated disturbance Complies ANSI C 63.4:2003 Conducted disturbance Complies ANSI C 63.4:2003 * : The compliance statement is based on nominal value only. Modification performed by the lab.; - N.A Laboratory’s Certificate Report number : LR500110806C Issue date : June 13, 2008 This test report is issued under the authority of: The test was supervised by: Dong –Min Bok – Soo KIM, Test Engineer JUNG, Technical Manager The results in this report apply only to the sample(s) tested. It is not allowed to copy this report even partly without the allowance of the test laboratory. Copyright © 2008, LTA CO., LTD. Page 5 of 26 Certification No. : LR500110806C General information’s Purpose This document is based on the Electromagnetic Interference (EMI) tests performed on the “MNC-300”. The measurements were performed according to the measurement procedure described in ANSI C 63.4:2003. The tests were carried out in order to confirm whether the electromagnetic emissions from the EUT( Equipment Under Test), are within the class A limits defined in FCC Part 15, Subpart B- “Section 15.107- Conducted limits” and “Section 15.109-Radiated emission limits”. Test Performed Company name : LTA Co., Ltd. Address : 243, Jubug-ri,Yangji-Myeon,Youngin-Si, Kyunggi-Do, Korea. 449-822 Telephone : +82-31-323-6008 Facsimile +82-31-323-6010 Measurement uncertainty Radiated disturbance (30 – 1000MHz) : +4.52 [dB] ,-4.43 [dB] (k=2) Conducted disturbance (0.15 – 30MHz) : +0.11 [dB] ,-0.11 [dB] (k=2) The coverage factor k=2 yields approx. a 95% level of confidence for near-normal distribution typical of most measurement results. Accredited agencies LTA Co., Ltd. Is approved to perform EMC testing by the following agencies: Agency Country Accreditation No. Validity NVLAP U.S.A 200723-0 2008-09-30 ECT accredited Lab. RRL KOREA KR0049 2009-06-20 EMC accredited Lab. FCC U.S.A 610755 2011-04-22 FCC filing VCCI JAPAN R2133, C2307 2011-06-22 VCCI registration IC CANADA IC5799A-1 2010-05-23 IC filing Copyright © 2008, LTA CO., LTD. Reference Page 6 of 26 Certification No. : LR500110806C Brief Information 1-1 Test Summary Parameter Applied Standard Status (note 1) I. Emission Radiated disturbance FCC Part 15.109 C Conducted disturbance FCC Part 15.107 C Note 1: C=Complies NC=Not Complies NT=Not Tested NA=Not Applicable * The data in this test report are traceable to the national or international standards. Frequency range to be scanned: 0.15 MHz - 30 MHz as conducted measurement 5th harmonic of the highest frequency or 40 GHz, whichever is lower Bandwidth: Measured by the CISPR quasi-peak function Bandwidth is 10kHz in the frequency 0.15MHz to 30MHz and 120kHz in the frequency 30MHz to 1,000MHz. Measured by the CISPR Peak function Bandwidth is 1MHz in the frequency 1GHz to 40GHz. A sample calculation: COR. F (correction factor)= Antenna factor + Cable loss- Amp.gain- Distance correction Emission Level= meter reading + COR.F Copyright © 2008, LTA CO., LTD. Page 7 of 26 Certification No. : LR500110806C 1-2 Operating Mode of the EUT The tests have been conducted with the following operational mode(s) of the EUT. Name of mode in the report Description Web camera + Ping - 1-3 Modification - None 1-4 List of EUT and accessory EUT Category Model Name Serial No. Manufacturer Remarks Dome Network Camera MNC-300 N/A MicroWeb Co., Ltd. - Model Name Serial No. Manufacturer Remarks CNG6500WPK HP - ACCESSORY Category PC HP Compaq dx2200 Microwtower Monitor VS11353 E060T0404 VIEWSONIC - Keyboard SK-8115 641-OEW DELL - Mouse M056UOA FOJOONOL DELL - Printer DESKJET 600K SG7631B1XX HP - TV Monitor N/A N/A N/A - Copyright © 2008, LTA CO., LTD. Page 8 of 26 Certification No. : LR500110806C 1-5 Cable List Cable List Remarks Type Length Shielding (Cable/backshell) ADAPTER 1.70 YES / NO DC ADAPTER LAN 5.70 YES / NO LAN LAN MIC 0.95 NO / NO MIC MIC IR 1.45 NO / NO IR IR From to 1-6 Block diagram of the EUT test 3 Pin AC Line 2 Pin AC Line A TV EUT A Printer PC Keyboard Monitor Mouse A : Adapter Note) refer to the Test setup photograph. Copyright © 2008, LTA CO., LTD. Page 9 of 26 Certification No. : LR500110806C 2- Test Site Description 1-Facility All the testing facilities are periodically serviced as a daily check for equipment and cables systems, an every 6 months facility check for the facilities and a monthly check and annual calibration for testing equipment according to ISO/IEC 17025. All the testing facilities are used as the same specifications shown below. There are descriptions both for radiated disturbance measurement and conducted disturbance measurement conformed by ANSI C 63.4:2003. The NSA measurement of the OATS was performed on Feb 8, 2008 according to ANSI C63.4 : 2003. 2-1 Radiated Disturbance Measurement Antenna to EUT Distance 10m change the Antenna with each frequency EUT Room Log-periodic Antenna EUT Antenna to ground distance 1m to 4m Biconical Antenna 0.8m Metal Ground Plane Size(7.2mx16m~7.2mx40m) Turn Table Amplifier Switch Coaxial Spectrum Analyzer EMI Receiver connections for equipment 2-2 Conducted Disturbance Measurement EUT 0.8m Vertical ground Plane AMN Horizontal ground Plane Pulse limitor 0.4m Bonded horizontal ground plane EMI Receiver connections for equipment Copyright © 2008, LTA CO., LTD. Page 10 of 26 to Certification No. : LR500110806C 3- Test Procedure 3-1 Radiated Disturbance Measurements ・Test site is met the requirements of ANSI C 63.4:2003 and the distance between the EUT and the antenna is adjusted 3m. ・The turntable can be rotated 360 degrees. ・The antenna can be adjusted between 1m and 4m in height above the ground. ・The EUT is placed on the non-conducting table with 0.8m height on the turntable. ・Measurements are carried out using a spectrum analyzer with peak detectors (100kHz bandwidth) and an EMI receiver with quasi-peak detectors(120kHz bandwidth). ・Refer to the list of test equipment used for the test. ・TRILOG antenna are used as wideband antenna. ・The TRILOG antenna is used in the frequency range of 30MHz to 1000MHz, the Horn antenna is used in the frequency range of 1GHz to 13GHz. ・A variable attenuator is used for verifying amplifier’s linearity. ・Rotating the turntable and adjusting the height of the antenna are carried out by control buttons on the console. ・Refer to "Brief Information"(page 5-8) about details of the EUT and configuration of the cables. ・Measurement is carried out by a LTA operator as manual operation. –searching for some of High disturbance frequency points than the other points with the following settings; bandwidth 100kHz, frequency range 10MHz between 30MHz and 300MHz and frequency range 50MHz between 300MHz and 1GHz. –searching the worst direction with the maximum level of the disturbance wave in rotating the turntable 360 degrees at each searched frequency point. –setting the height of the antenna with the maximum level of the disturbance wave from 1m to 4m. –reading the disturbance level by the EMI receiver with quasi-peak detectors (120kHz bandwidth) according to ANSI C 63.4:2003. –measuring to vertical and horizontal polarization. –calculating the measurement result with the following formula or equation: (Measurement result= measured value + antenna factor + antenna cable loss) Copyright © 2008, LTA CO., LTD. Page 11 of 26 Certification No. : LR500110806C 3-2 Conducted Disturbance Measurements ・The measurement is carried out on an open site with horizontal and metallic ground plane. ・An AMN(Artificial Mains Network) with a nominal impedance (50Ω/50μH) as defined in ANSI C 63.4:2003, shall be utilized. ・The AMN is grounded on a horizontal metal ground plane. ・Measurement is carried out using an EMI receiver with quasi-peak detectors and average detector. (Refer to the List of test equipment used for the test.) ・The shortest distance between the EUT and the AMN is 0.8m. ・The EUT is placed on the non-conducting table with 0.8m height. ・A remote switch is used for changing phases between Line (L) and Neutral (N). ・Refer to "Brief Information"(page 5-8 ) about details of the EUT and configuration of the cables. ・Measurement is carried out as manual operation. –detecting the maximized emission level using the maxhold function after setting the spectrum analyzer bandwidth 1MHz and the frequency range from 150kHz to 1MHz , 1MHz to 5MHz and 5MHz to 30MHz. –searching the maximum frequency point of the disturbance wave in each frequency range. –reading the disturbance level of quasi-peak, average and Line (L) and Neutral (N) in 9kHz bandwidth by the EMI receiver. –calculating the measurement result with the following formula or equation. (Result = Reading + Cor.F.) (Margin = Limit- Result) Copyright © 2008, LTA CO., LTD. Page 12 of 26 Certification No. : LR500110806C 4- List of Equipment Used For the Tests Item Model Name Serial No. Manufacturer Interval Last Cal. 1 Spectrum Analyzer 8594E 3624A03247 HP 1 year Oct-12-07 2 Test Receiver ESHS10 828404009 R&S 1 year Aug-24-07 3 Two-Line V-Network ENV216 100408 R&S 1 year Dec-07-07 4 Two-Line V-Network ESH3-Z5 893045/017 R&S 1 year Oct-12-07 5 EMI Test Receiver ESVD 843748/001 R&S 1 year Aug-24-07 6 Spectrum Analyzer 8591E 3649A05888 HP 1 year Oct-12-07 7 RF Amplifier 8447D 2949A02670 HP 2 year Jan-25-07 8 RF Amplifier 8447D 2439A09058 HP 1 year Oct-12-07 9 TRILOG Antenna VULB9160 9160-3212 SCHWARZBECK 2 year Jul-05-06 10 RF Switch MP59B 6200414971 ANRITSU 2 year May-28-07 11 Splitter ZFM-150 15542 Mini-Circuits 1 year Apr-02-08 12 RF Amplifier 8449B 3008A02126 HP 1 year Apr-03-08 13 Horn Antenna 3115 00055005 ETS 2 year Mar-15-07 Copyright © 2008, LTA CO., LTD. Page 13 of 26 Certification No. : LR500110806C 5-1 Radiated Disturbance Measurements Copyright © 2008, LTA CO., LTD. Page 14 of 26 Certification No. : LR500110806C 5-2 Conducted Disturbance Measurements Copyright © 2008, LTA CO., LTD. Page 15 of 26 Certification No. : LR500110806C 5-2 Conducted Disturbance Measurements Copyright © 2008, LTA CO., LTD. - Continue Page 16 of 26 Certification No. : LR500110806C Conclusions Product models " MNC-300 " meets all of the Class A requirements of the FCC Part 15, Subpart B. (Limits of radio disturbance characteristics of ITE). ( Refer to Test Specification and Test Results in the "LTA certification", page3.) Copyright © 2008, LTA CO., LTD. Page 17 of 26 Certification No. : LR500110806C Photograph of the Radiated Disturbance Measurements Copyright © 2008, LTA CO., LTD. Page 18 of 26 Certification No. : LR500110806C Photograph of the Conducted Disturbance Measurement Copyright © 2008, LTA CO., LTD. Page 19 of 26 Certification No. : LR500110806C Photograph of the Equipment Under Test Copyright © 2008, LTA CO., LTD. Page 20 of 26 Certification No. : LR500110806C Photograph of the Equipment Under Test Copyright © 2008, LTA CO., LTD. Page 21 of 26 Certification No. : LR500110806C Photograph of the Equipment Under Test Copyright © 2008, LTA CO., LTD. Page 22 of 26 Certification No. : LR500110806C Photograph of the Equipment Under Test Copyright © 2008, LTA CO., LTD. Page 23 of 26 Certification No. : LR500110806C Photograph of the Equipment Under Test Copyright © 2008, LTA CO., LTD. Page 24 of 26 Certification No. : LR500110806C Photograph of the Equipment Under Test Copyright © 2008, LTA CO., LTD. Page 25 of 26 Certification No. : LR500110806C Photograph of the Equipment Under Test Copyright © 2008, LTA CO., LTD. Page 26 of 26
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.6 Linearized : Yes Encryption : Standard V2.3 (128-bit) User Access : Print, Extract, Print high-res XMP Toolkit : 3.1-701 Producer : Acrobat Distiller 7.0 (Windows) Create Date : 2008:07:09 11:59:41+09:00 Creator Tool : PScript5.dll Version 5.2 Modify Date : 2008:07:09 12:02:08+09:00 Metadata Date : 2008:07:09 12:02:08+09:00 Format : application/pdf Title : Microsoft Word - [MNC-300] FCC ver.doc Creator : Administrator Document ID : uuid:124fc970-df32-4816-8cc1-873278e511fe Instance ID : uuid:5b19f7f4-9598-4656-bc65-128dab955d97 Page Count : 27 Author : AdministratorEXIF Metadata provided by EXIF.tools