C2924M-QS.fm Page 1 Wednesday, April 27, 2005 3:26 PM

C2924M-QS (4/05)
CCC1390H Series Camera
Quick Start Guide

SETUP MENUS
Use the setup menus to customize the camera settings. Refer to the setup menus as shown on this and
the opposite page.

This quick start guide describes how to install and configure the CCC1390H Series camera in most
applications. It contains a representation of the setup menus to help you locate and change specific
settings.
Refer to the enclosed CD for the following documentation:

•
•
•

V-PHASE ADJ

LINE SYNC
MAIN MENU

Installation/Operation manual: INSTALL.PDF
Quick Start Guide: QSG.PDF
Important Safety Instructions: SAFETY.PDF

MODELS

PROFILES
EXPOSURE SETTINGS
FUNCTION SETTINGS
CAMERA SETUP
AI AUTO ADJUSTMENT
PIXEL CORRECTION
SYSTEM INFORMATION

CAMERA SETUP
>
>
>
>
>
>
>

ADDRESS
COM SPEED
LED
SWITCH

>1
> 4800
> ON
> ON

EXIT

BACK

EXIT

CCC1390H-6

1/3-inch high resolution day/night, WDR, CCD camera, 24 VAC or 12 VDC, NTSC format

CCC1390H-6X

1/3-inch high resolution day/night, WDR, CCD camera, 24 VAC or 12 VDC, PAL format

> AUTO
>

BACK

EXIT

MANUAL RED/BLUE

> STANDARD
> CUSTOM
STANDARD

OK

> -1
> -2
>1
>1

BACK

EXIT



PIXEL CORRECTION


BACK

EXIT

APERTURE GAIN

> -1

BACK

EXIT

CANCEL

E-ZOOM

3a
 

PHASE VALUE = 45

SHARPNESS

RED GAIN
BLUE GAIN
RED HUE
BLUE HUE
AI AUTO ADJUSTMENT

PROFILES
ACTIVE
SAVE AS
*DEFAULT

LINE SYNC
V-PHASE ADJ

POSITION

ZOOM
POSITION

> OFF
>

BACK

EXIT

COVER THE LENS
AND SELECT OK
OK

CANCEL

EXPOSURE SETTINGS



 



AUTO EXPOSURE
VIDEO LEVEL
FLICKERLESS
AGC
DSS(SENS)
DAY & NIGHT
D&N DETECTION
D&N FILTER LIMIT
BACK

> NORMAL
>0
> OFF
> ON
>4
> COLOR
>
>
EXIT



Lens Mount
Back Focus Locking Screw
Camera Mount and 3a Adapter
Serial Terminating Switch
Auto Iris Lens Connector






Video Output Connector
Setup Button
Power Terminal Strip
Indicators

FIRMWARE VERSION
OSD VERSION

1.0
1.0

RESTORE FACTORY SETTINGS

>

BACK

EXIT

MASK SETTING

MASK
MASK EDIT
MASK ERASE

> OFF
>

BACK

EXIT

EDIT TITLE

TITLE
RESTORE FACTORY SETTINGS

FUNCTION SETTINGS






MASKING
SYSTEM INFORMATION

LINE SYNC
WHITE BALANCE
MANUAL RED/BLUE
GAMMA
SHARPNESS
E-ZOOM
MASKING
TITLE
BACK

>
> AUTO
>
> 60%(NORM)
>
>
>
>
EXIT

OK

TITLE
EDIT TITLE

> OFF
>

BACK

EXIT

CANCEL

ABCDEFGHIJKLM
NOPQRSTUVWXYZ
abcdefghijklm
nopqrstuvwxyz
0123456789-/
BACK
________________

BS

C2924M-QS.fm Page 2 Wednesday, April 27, 2005 3:26 PM

LENS
The CCC1390H Series camera supports both manual and DC-drive auto iris lenses, either fixed focal
length or varifocal. It automatically senses an auto iris lens as soon as you plug in the connector.
The camera has a standard CS-mount that can accept a C-mount lens with a PCMA40 lens adapter.
To mount the lens onto the camera:
1. Use clean, compressed air or a clean, dry lens cloth to make sure there is no dust or other foreign
matter between the lens and the camera imager.
2. C-mount lens: Screw the adapter onto the lens.
3. Screw the lens onto the lens mount.
4. DC-drive auto iris lens: Connect the four-pin connector from the lens to the connector on the
back of the camera.

MOUNT
The CCC1390H Series camera can be mounted from either the top or bottom, depending on the type of
camera mount used in your installation. Use a standard 1/4-20 screw. The maximum thread depth (top)
is 0.188 inches (4.7 mm). To extend the thread depth (top) to 0.25 inches (6.4 mm), use the camera mount
spacer (supplied). The maximum thread depth (bottom) is 0.25 inches (6.4 mm).

ELECTRICAL
Power
Connect 12 VDC or 24 VAC power to the three-pin terminal strip on the back of the camera. Use a Class 2
isolated power source for the CCC1390H camera that can supply 12 VDC ±15% or 24 VAC ±15%,
50/60 Hz. Maximum power consumption is about 3.5 watts.

Video
Connect a coaxial video cable to the BNC connector on the back of the camera.

External Control
For serial control, install the control connector (refer to Connecting External Control in the Installation/
Operation manual for more information).

NOTE: After you customize any aspect of the CCC1390H Series camera, be sure to save your custom
settings. (Refer to Profiles in the Installation/Operation manual for information about saving custom
settings.)

BUTTON ACTION

Enter setup menus.

Long center press

Move up or down in menu or item options.

Up or down press

Move right or left in menu.

Right or left press

Select menu or item.

Short center press

Save setting and exit to menu.

Short center press

Adjust the back focus:

LENS FOCUS

(1)

Use a 1.5-mm Allen wrench to loosen the back focus locking screw.

After mounting the lens, you must focus your CCC1390H Series camera. You will adjust both the back
focus (on the camera) and the fine focus (on the lens).

(2)

Turn the lens until the image is focused.

(3)

Tighten the back focus locking screw clockwise.

NOTE: The back focus has already been adjusted using a standard CS-mount lens. However, you might
need to adjust it again to match the mounted lens.
1. Auto iris only: Cover the auto iris lens
with a suitable neutral density (ND) filter.
This opens the iris fully. For best results,
use an ND3 filter.
2. Manual iris only: Open the iris
completely. The figure shows the manual
iris, varifocal, and lens focus locking
screws for a sample lens. Refer to your
lens documentation for more
information.

a.

Display the EXPOSURE
SETTINGS menu.

8. Tighten all lens locking screws.
NOTE: When tightening the lens locking screws, do not over-turn or force any screw.
9. Auto iris only: Remove the ND filter.
10. If necessary, disable AGC:
LENS FOCUS
LOCKING SCREW
VARIFOCAL

b.
c.

1.5 MM
ALLEN
WRENCH

Change AGC to ON.
LOCKING
SCREW
Select EXIT to save the AGC
setting.
4. Aim the camera at the farthest object in the field of view. Make sure it is at least 6.5 ft (2 m) away.
5. Fixed focal length lens only:
a.

WARNING: Do not over-tighten the back focus locking screw because you may damage the
camera.
Back focus is a coarse adjustment. You will make the fine focus adjustment in steps c and d.
c.
Move the varifocal locking screw up or down to set the field of view.
d.
Adjust the lens focus to achieve the best fine focus.
e.
Repeat steps c and d until the focus is correct.
7. Manual iris only: Adjust the iris for the best picture quality. The largest aperture gives the best
light sensitivity; the smallest aperture gives the greatest depth of field.

MANUAL IRIS
LOCKING SCREW

3. If necessary, enable Automatic Gain
Control (AGC) on the EXPOSURE
SETTINGS menu. AGC is enabled by
default.

Use the five-position button on the rear panel to access and navigate the setup menus. The following
table lists the button presses for each menu action.
MENU ACTION

Set the varifocal to wide (W) and the lens focal length to far (∞).

a.
b.

b.

ACCESSING THE SETUP MENUS

6. Varifocal lens only:

Set the lens focal length to far (∞).

a.

Display the EXPOSURE SETTINGS menu.

b.
Change AGC to OFF.
c.
Select EXIT to save the AGC setting.
11. Auto iris only: Perform the auto iris lens adjustment procedure (refer to Auto Iris Lens
Adjustment in the Installation/Operation manual for more information).
12. As soon as you finish customizing this and all other camera settings, save your custom settings
into the CUSTOM profile. This protects them in case the camera loses power or must be restarted
(refer to Profiles in the Installation/Operation manual for more information).

Adjust the back focus:

(1)

Use a 1.5-mm Allen wrench to loosen the back focus locking screw.

(2)

Turn the lens until the image is focused.

(3)

Tighten the back focus locking screw clockwise.

WARNING: Do not over-tighten the back focus locking screw because you may damage the
camera.

REVISION HISTORY
Manual #
C2924M-QS

Date
4/05

Comments
Original version.

Pelco and the Pelco logo are registered trademarks of Pelco.

c.

Back focus is a coarse adjustment. You will make the fine focus adjustment in the next step.
Adjust the lens focus to achieve the best fine focus.

©Copyright 2005, Pelco. All rights reserved.

Worldwide Headquarters • 3500 Pelco Way • Clovis, California 93612 USA • www.pelco.com
USA & Canada • Tel: 800/289-9100 • Fax: 800/289-9150
International • Tel: 1-559/292-1981 • Fax: 1-559/348-1120
C2924M-QS (4/05)



Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.4
Linearized                      : Yes
Encryption                      : Standard V1.2 (40-bit)
User Access                     : Print, Copy, Annotate, Fill forms, Extract, Assemble, Print high-res
Modify Date                     : 2005:04:27 15:32:57-07:00
Create Date                     : 2004:07:20 17:06:37Z
Page Count                      : 2
Creation Date                   : 2004:07:20 17:06:37Z
Mod Date                        : 2005:04:27 15:32:57-07:00
Producer                        : Acrobat Distiller 5.00 for Macintosh
Author                          : 
Metadata Date                   : 2005:04:27 15:32:57-07:00
Creator                         : 
Title                           : C2924M-QS.fm
Page Mode                       : UseNone
EXIF Metadata provided by EXIF.tools

Navigation menu