Pepperl Fuchs IQH1-FP-V1 RFID reader User Manual Data Sheet

Pepperl + Fuchs Inc RFID reader Data Sheet

user manual

Download: Pepperl Fuchs IQH1-FP-V1 RFID reader User Manual Data Sheet
Mirror Download [FCC.gov]Pepperl Fuchs IQH1-FP-V1 RFID reader User Manual Data Sheet
Document ID2198735
Application IDP3Bqr9MCmWg2KiU0Z7HzTA==
Document Descriptionuser manual
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize15.88kB (198543 bits)
Date Submitted2014-02-24 00:00:00
Date Available2014-02-24 00:00:00
Creation Date2001-07-26 09:05:51
Producing SoftwareAcrobat Distiller 6.0.1 (Windows)
Document Lastmod2014-02-21 12:22:05
Document TitleData Sheet
Document CreatorFrameMaker 7.0
Document Author: MB, Pepperl+Fuchs GmbH

Read/write head
IQH1-FP-V1
Dimensions
40
80
LED
11 16
M12 x 1
Ø5.3
65
M20 x 1.5
65
Electrical connection
Model Number
IQH1-FP-V1
Read/write head
for IDENTControl
Shield
Features
• Operating frequency 13.56 MHz
• Conforms to ISO 15693
• Suitable for FRAM transponder
• Dual-LED for function display
• Connection via V1 (M12 x 1) plug
connection
• Degree of protection IP67
Technical data
General specifications
Operating frequency
Transfer rate
Sensing range
Read distance
Write distance
Width
UL File Number
0 ... 130 mm
0 ... 130 mm
max. 100 mm
E87056
Functional safety related parameters
MTTFd
Mission Time (TM)
Diagnostic Coverage (DC)
680 a
10 a
0%
13.56 MHz
26 kBit/s
Release date: 2014-02-21 09:23 Date of issue: 2014-02-21 204623_eng.xml
Indicators/operating means
LED green/yellow
Electrical specifications
Power consumption
Supply
green: power on
green flashing: read/write attempt performed
yellow: data carrier detected
P0
Ambient conditions
Ambient temperature
Storage temperature
≤ 1.3 W
from the IDENTControl
-25 ... 70 °C (-13 ... 158 °F)
-40 ... 85 °C (-40 ... 185 °F)
Mechanical specifications
Degree of protection
Connection
Material
Housing
Base
Encapsulation compound
Installation
Distance between two heads
IP67
M12 x 1 connector
PBT
diecast aluminum
CY 221/HY 2966
Multiplex on: ≥ 100 mm
Multiplex off: ≥ 150 mm
approx. 380 g
Mass
Compliance with standards and directives
Directive conformity
R&TTE Directive 1995/5/EC
EN 301489-1 V1.8.1 (2008-04), EN 301489-3 V1.4.1 (2002-08),
EN 300330-2 V1.3.1 (2006-04), EN 60950-1:2006
Standard conformity
Refer to “General Notes Relating to Pepperl+Fuchs Product Information”.
Pepperl+Fuchs Group
USA: +1 330 486 0001
Germany: +49 621 776 4411
fa-info@de.pepperl-fuchs.com
www.pepperl-fuchs.com
fa-info@us.pepperl-fuchs.com
Singapore: +65 6779 9091
fa-info@sg.pepperl-fuchs.com
Read/write head
Electromagnetic compatibility
Degree of protection
RFID
Approvals and certificates
FCC approval
IQH1-FP-V1
EN 61000-6-2, EN 61000-6-4
EN 60529
ISO/IEC 15693-2:2006 , ISO/IEC 15693-3:2009 , ISO/IEC
18000-3 ,
Accessories
IQC21-50P
Data carrier
This device complies with part 15 of the FCC rules. Operation is
subject to the following two conditions:
(1) This device may not cause harmful interference, and
(2) This device must accept any interference received, including
interference that may cause undesired operation.
Caution:
Changes or modifications not expressly approved by the party
responsible for compliance could void the user's authority to
operate the equipment.
Notes
This equipment has been tested and found to comply with the limits for a Class A digital device,
pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not
installed and used in accordance with the instruction manual, may cause harmful interference
to radio communications. Operation of this equipment in a residential area is likely to cause
harmful interference in which case the user will be required to correct the interference at his
own expense.
IQC21-58
Data carrier
IQC22-C5
Data carrier
IQC33-20
Data carrier
IQC33-30
Data carrier
IQC33-50
Data carrier
V1-G-5M-PUR-ABG-V1-W
Connecting cable, M12 to M12, PUR cable 4-pin, shielded
V1-G-10M-PUR-ABG-V1-W
Connecting cable, M12 to M12, PUR cable 4-pin, shielded
IQC24-27-T12
Data carrier
IQC31-22-T9
Data carrier
IQC22-22CT-T9
Data carrier
IQC22-C1 UNPRINTED
Data carrier
Release date: 2014-02-21 09:23
Date of issue: 2014-02-21
204623_eng.xml
AB-FP
Mounting aid
Refer to “General Notes Relating to Pepperl+Fuchs Product Information”.
Pepperl+Fuchs Group
USA: +1 330 486 0001
Germany: +49 621 776 4411
fa-info@de.pepperl-fuchs.com
www.pepperl-fuchs.com
fa-info@us.pepperl-fuchs.com
Singapore: +65 6779 9091
fa-info@sg.pepperl-fuchs.com

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.2
Linearized                      : Yes
Encryption                      : Standard V1.2 (40-bit)
User Access                     : Print, Copy, Annotate, Fill forms, Extract, Assemble, Print high-res
Page Count                      : 2
Page Mode                       : UseNone
XMP Toolkit                     : XMP toolkit 2.9.1-13, framework 1.6
About                           : uuid:53d30eae-2d7f-4f64-8eed-5ee2a517118b
Producer                        : Acrobat Distiller 6.0.1 (Windows)
Create Date                     : 2001:07:26 09:05:51Z
Creator Tool                    : FrameMaker 7.0
Modify Date                     : 2014:02:21 12:22:05Z
Document ID                     : uuid:f5a6dfc0-fbf5-49ed-968a-f93b9f50add5
Format                          : application/pdf
Creator                         : MB, Pepperl+Fuchs GmbH
Description                     : Identification Systems
Title                           : Data Sheet
Author                          : MB, Pepperl+Fuchs GmbH
Subject                         : Identification Systems
EXIF Metadata provided by EXIF.tools
FCC ID Filing: IREIQH1-FP-V1

Navigation menu