FACTORY AUTOMATION
MANUAL
IUH-F190-V1-*
IUT-F190-R4-V1*
UHR Read/Write Head
for IDENTControl
IUH-F190-V1-*, IUT-F190-R4-V1*
With regard to the supply of products, the current issue of the following document is applicable: The General Terms of Delivery for Products and Services of the Electrical Industry, published by the Central Association of the Electrical Industry (Zentralverband
Elektrotechnik und Elektroindustrie (ZVEI) e.V.) in its most recent version as well as the
supplementary clause: "Expanded reservation of proprietorship"
IUH-F190-V1-*, IUT-F190-R4-V1*
Introduction................................................................................. 7
1.1
Content of this Document ................................................................... 7
1.2
Target Group, Personnel...................................................................... 7
1.3
Symbols Used ...................................................................................... 8
Certificates and Approvals ........................................................ 9
2.1
Declaration of Conformity (RE Directive 2014/53/EU)...................... 9
2.2
FCC-Information................................................................................... 9
2.3
IC-Information..................................................................................... 10
2.4
UL Information.................................................................................... 10
2.5
Additional Country-Specific Approvals ........................................... 10
Product Description ................................................................. 11
3.1
RFID Frequency Bands...................................................................... 11
3.2
UHF general ........................................................................................ 11
3.2.1 Advantages of UHF.......................................................................... 11
3.2.2 Applications for UHF Systems ......................................................... 11
3.2.3 Memory Structure of a Tag acc. to EPC Gen 2 ................................. 12
3.2.4 Electronic Product Code (EPC)........................................................ 14
3.2.5 Influence of Various Materials on the Sensing Range ...................... 14
3.2.6 Dense Reader Mode (DRM) ............................................................ 15
3.2.7 Frequency Hopping Spread Spectrum............................................. 16
3.2.8 Relevant Standards for UHF............................................................. 17
IUH-F190-V1-*, IUT-F190-R4-V1*
3.3
Countries of Use.................................................................................17
3.3.1 European Union ............................................................................... 17
3.3.2 Argentina.......................................................................................... 18
3.3.3 Australia ........................................................................................... 18
3.3.4 Brazil ................................................................................................ 18
3.3.5 Canada ............................................................................................ 18
3.3.6 China................................................................................................ 18
3.3.7 Hong Kong .......................................................................................19
3.3.8 India ................................................................................................. 19
3.3.9 Japan ............................................................................................... 19
3.3.10 Colombia.......................................................................................... 19
3.3.11 Malaysia ........................................................................................... 19
3.3.12 Mexico.............................................................................................. 20
3.3.13 New Zealand .................................................................................... 20
3.3.14 Russia .............................................................................................. 20
3.3.15 Singapore......................................................................................... 20
3.3.16 South Korea .....................................................................................21
3.3.17 Thailand ........................................................................................... 21
3.3.18 United States of America .................................................................. 22
3.3.19 Vietnam ............................................................................................ 22
3.4
General Functions and Features .......................................................23
3.5
Indicators and Operating Elements ..................................................24
3.6
Connection..........................................................................................24
3.7
Scope of Delivery ...............................................................................25
3.8
Accessories ........................................................................................25
3.8.1 IDENTControl ...................................................................................25
3.8.2 Read/Write Tags............................................................................... 26
3.8.3 Connection Cable for R/W Heads and Trigger Sensors.................... 26
3.8.4 Cable Connectors for the Power Supply........................................... 27
3.8.5 Mounting Set .................................................................................... 27
Installation................................................................................. 28
4.1
Storage and Transport .......................................................................28
4.2
Unpacking ...........................................................................................28
IUH-F190-V1-*, IUT-F190-R4-V1*
4.3
Mounting ............................................................................................. 28
4.3.1 Room Orientation............................................................................. 29
4.3.2 Minimum Distances ......................................................................... 30
4.3.3 Polarization ...................................................................................... 30
4.4
Connection ......................................................................................... 31
4.5
EMC Concept...................................................................................... 32
Commissioning......................................................................... 33
5.1
Definitions........................................................................................... 33
5.1.1 Display............................................................................................. 33
5.1.2 Legend............................................................................................. 33
5.2
Sensor Settings.................................................................................. 34
5.3
Operation via the Command Interface ............................................. 34
Operation................................................................................... 37
6.1
General ................................................................................................ 37
6.2
Basic Command Process .................................................................. 37
6.3
Command Overview .......................................................................... 38
6.4
Read/Write Commands...................................................................... 39
6.5
Filter Commands................................................................................ 44
6.6
Configuration Commands ................................................................. 47
6.6.1 Read and Write Parameters ............................................................. 48
6.6.2 Parameters ...................................................................................... 49
6.7
Read/Write Head with Integrated RS-485 Interface ........................ 60
6.7.1 Single-Drop Mode............................................................................ 60
6.7.2 Multi-Drop Mode .............................................................................. 61
6.8
Error/Status Messages ...................................................................... 63
IUH-F190-V1-*, IUT-F190-R4-V1*
Service and Maintenance ........................................................ 65
Troubleshooting........................................................................ 66
Appendix ................................................................................... 67
9.1
Dimensions .........................................................................................67
9.2
ASCII Table ..........................................................................................67
9.3
Detection Range .................................................................................68
IUH-F190-V1-*, IUT-F190-R4-V1*
Introduction
Introduction
1.1
Content of this Document
This document contains information required to use the product in the relevant phases of the
product life cycle. This may include information on the following:
■
Product identification
■
Delivery, transport, and storage
■
Mounting and installation
■
Commissioning and operation
■
Maintenance and repair
■
Troubleshooting
■
Dismounting
■
Disposal
Note!
Visit www.pepperl-fuchs.com to access further documentation for full information about the
product.
The documentation comprises the following parts:
■
This document
■
Datasheet
In addition, the documentation may comprise the following parts, if applicable:
1.2
■
EU-type examination certificate
■
EU declaration of conformity
■
Attestation of conformity
■
Certificates
■
Control drawings
■
Instruction manual
■
Other documents
Target Group, Personnel
Responsibility for planning, assembly, commissioning, operation, maintenance, and
dismounting lies with the plant operator.
Only appropriately trained and qualified personnel may carry out mounting, installation,
commissioning, operation, maintenance, and dismounting of the product. The personnel must
have read and understood the instruction manual and the further documentation.
2017-12
Prior to using the product make yourself familiar with it. Read the document carefully.
IUH-F190-V1-*, IUT-F190-R4-V1*
Introduction
1.3
Symbols Used
This document contains symbols for the identification of warning messages and of informative
messages.
Warning Messages
You will find warning messages, whenever dangers may arise from your actions. It is mandatory
that you observe these warning messages for your personal safety and in order to avoid
property damage.
Depending on the risk level, the warning messages are displayed in descending order as
follows:
Danger!
This symbol indicates an imminent danger.
Non-observance will result in personal injury or death.
Warning!
This symbol indicates a possible fault or danger.
Non-observance may cause personal injury or serious property damage.
Caution!
This symbol indicates a possible fault.
Non-observance could interrupt the device and any connected systems and plants, or result in
their complete failure.
Informative Symbols
Note!
This symbol brings important information to your attention.
Action
2017-12
This symbol indicates a paragraph with instructions. You are prompted to perform an action or
a sequence of actions.
IUH-F190-V1-*, IUT-F190-R4-V1*
Certificates and Approvals
Certificates and Approvals
2.1
Declaration of Conformity (RE Directive 2014/53/EU)
This product was developed and manufactured under observance of the applicable European
standards and guidelines.
Note!
A Declaration of Conformity can be requested from the manufacturer or downloaded from
www.pepperl-fuchs.com.
The product manufacturer, Pepperl+Fuchs GmbH, 68307 Mannheim, has a certified quality
assurance system that conforms to ISO 9001.
ISO9001
2.2
FCC-Information
FCC ID: IREIUHF190V1B
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two
conditions:
1. this device may not cause harmful interference, and
2. this device must accept any interference received, including interference that may cause
undesired operation.
Attention:
Changes or modifications not expressly approved by the party responsible for compliance
could void the user's authority to operate the equipment.
Note:
This equipment has been tested and found to comply with the limits for a Class A digital device,
pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable
protection against harmful interference when the equipment is operated in a commercial
environment. This equipment generates, uses, and can radiate radio frequency energy and, if
not installed and used in accordance with the instruction manual, may cause harmful
interference to radio communications. Operation of this equipment in a residential area is likely
to cause harmful interference in which case the user will be required to correct the interference
at his own expense.
FCC Notice
To comply with FCC part 15 rules in the United States, the system must be professionally
installed to ensure compliance with the Part 15 certification. It is the responsibility of the
operator and professional installer to ensure that only certified systems are deployed in the
United States. The use of the system in any other combination (such as co-located antennas
transmitting the same information) is expressly forbidden.
FCC Exposure Information
2017-12
To comply with FCC RF exposure compliance requirements, the antennas used for this
transmitter must be installed to provide a separation distance of at least 30 cm from all persons
and must not be co-located or operated in conjunction with any other antenna or transmitter.
IUH-F190-V1-*, IUT-F190-R4-V1*
Certificates and Approvals
2.3
IC-Information
This device complies with Industry Canada licence-exempt RSS standard(s) and with part 15
of the FCC Rules. Operation is subject to the following two conditions:
1. this device may not cause interference, and
2. this device must accept any interference, including interference that may cause undesired
operation of the device.
Le présent appareil est conforme aux CNR d'Industrie Canada applicables aux appareils
radio exempts de licence. L'exploitation est autorisée aux deux conditions suivantes :
1. l'appareil ne doit pas produire de brouillage, et
2. l'utilisateur de l'appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est susceptible d'en compromettre le fonctionnement.
IC Exposure Information
To comply with IC RF exposure compliance requirements, the antennas used for this
transmitter must be installed to provide a separation distance of at least 30 cm from all persons
and must not be co-located or operated in conjunction with any other antenna or transmitter.
2.4
UL Information
Technical Data and Environmental Conditions
This device is for indoor use only.
This device may be operated in altitudes up to 2000 m.
The ambient temperature range is from -20 °C to +70 °C for operation with non-transmission
periods, or -20 °C to +60 °C for continuous transmission mode.
The maximum relative humidity is 80 % for temperatures up to 31 °C decreasing linearly to 50%
relative humidity at 40 °C.
Nominal power supply voltage is 24 V DC, voltage range is 20 ... 30 V DC. Supply must be PELV
(Protective Extra Low Voltage). This is the case if Pepperl+Fuchs IDENTControl control
interface is used.
Protection class IP67 is not included in the UL approval. The protection class is tested by
Pepperl + Fuchs GmbH.
2.5
Additional Country-Specific Approvals
2017-12
For all current approvals see the data sheet of your read / write head under www.pepperlfuchs.com.
10
IUH-F190-V1-*, IUT-F190-R4-V1*
Product Description
Product Description
3.1
RFID Frequency Bands
0,1
LF
10
HF
100
5,8 GHz
2,45 GHz
1000
UHF MW
10000
Frequency
[MhZ]
■
100 kHz ... 135 kHz: Low frequency LF
■
13.56 MHz: High frequency HF
■
865 MHz ... 868 MHz (Europe), 902 MHz ... 928 MHz (USA), 920 MHz ... 925 MHz
(China): ultra-high frequency UHF
■
2.45 GHz and 5.8 GHz: Microwave MW
3.2
UHF general
3.2.1
Advantages of UHF
■
Long detection range
■
UHF tags are available as cheap and space-saving adhesive labels
■
High transfer rates
■
Tag is available with a large working memory (user memory)
■
Bulk detection
Applications for UHF systems
■
Identification in galvanic coating or painting systems used in automotive production,
■
Identification feasible over greater distances than with LF and HF systems,
■
Identification of automotive superstructures in automotive production,
■
Pallet identification and measurement of goods movements in the logistics sector, and
■
Access control at unloading stations with HGV identification.
2017-12
3.2.2
868/915 MHz
125 kHz
13,56 MHz
The following diagram shows the position of the different frequency bands used for RFID. The
read/write heads described in this manual operate in the frequency range from 865 MHz ...
868 MHz and from 902 MHz ... 928 MHz, highlighted in color.
11
IUH-F190-V1-*, IUT-F190-R4-V1*
Product Description
3.2.3
Memory Structure of a Tag in Accordance with EPC Gen 2
(ISO/IEC 18000-63)
MSB
LSB
10h
00h
RFU
[7:0]
DSFID
[7:0]
MSB
Commands
Read / write head
SR/ER
SW/EW
Memory module
USER
SF/EF
Bank 10
TID
SS/ES
SP
Bank 01
UII/EPC
Bank 00
RESERVED
0Fh
LSB
10h
Bank 11
1Fh
00h
TID
[15:0]
TID
[31:16]
MSB
1Fh
0Fh
LSB
220 h
Optional XPC_W2
[15:0]
22F h
210 h
Optional XPC_W2
[15:0]
21F h
UII/EPC
[15:0]
20h
10h
00h
UII/EPC
[N:N-15]
PC
[15:0]
CRC-16
[15:0]
MSB
2Fh
1Fh
0Fh
LSB
30h
20h
10h
00h
Access Password
[15:0]
Access Password
[31:16]
Kill Password
[15:0]
Kill Password
[31:16]
3Fh
2Fh
1Fh
0Fh
The memory module of an EPC Gen 2 (ISO/IEC 18000-63) tag is split into four segments. The
main contents of these segments are:
Segment
Function
Bank 00
Password
(00 bin = 0 dec ) management
Length
Depending on the tag type, /column "Bank 00"
Bank 01
Unique Item Identifier Depending on the tag type, /column "UII/EPC"
(01 bin = 1 dec ) (UII)
Electronic Product
Code (EPC)
4 bytes (MDID, TMN) + 0, 4, or 8 bytes
Bank 11
User memory
(11 bin = 3 dec )
Depending on the tag type, /column "User Data"
2017-12
Bank 10
Tag ID (TID)
(10 bin = 2 dec )
12
IUH-F190-V1-*, IUT-F190-R4-V1*
Product Description
Bank 00: Password Management
The segment Bank 00 contains the password management information, comprising the
access password and the kill password. The read/write head manages the kill password with
the standard read/write commands SW and SR. The access password is not supported. See
"Single Read Words SR" on page 42, see "Single Write Words SW" on page 42, and see
"Memory Module for Tag Accesses to the "Memory Bank" MB" on page 52.
Bank 01: UII/EPC
In addition to the Unique Item Identifier (UII), the segment Bank 01 contains a calculated
checksum CRC (Cyclic Redundancy Check) for verifying data on the tag and the protocol
control (PC) area. The PC area contains:
■
The length of the UII
■
The Application Family Identifier (AFI) box
■
A bit switch that shows whether the UII contains an EPC sequence of numbers in
accordance with ISO (see chapter 3.2.4)
■
A bit switch that shows whether data is stored in segment bank 11 (if present)
The data is addressed via the following commands: single read special read-only code (SS),
single write special read-only code (SP), and enhanced read special read-only code (ES). See
"Single Read Special Read-Only Code SS" on page 40, see "Single Write Special Read-Only
Code SP" on page 41, and see "Enhanced Read Special Read-Only Code ES" on page 40.
Bank 10: TID
The segment Bank 10 contains the tag identifier (TID), consisting of the part number and
optional serial number of the tag. This data is permanently stored without being changed. The
first byte denotes the class of the tag with E0 hex, E2 hex, or E3 hex. The rest of the TID depends
on the class, and can be derived from standard ISO/IEC 18000-63.
Example:
All tags with the class EPC Gen 2 (ISO/IEC 18000-63) are marked with E2hex . The TID is
comprised as follows:
■
4 bytes: part number of the tag
■
• 1 byte: identifier
• 12 bits: tag mask designer identifier (MDID)
• 12 bits: tag model number (TMN), defined by the manufacturer:
4 or 8 bytes: serial number of the tag
Depending on the manufacturer, the serial numbers do not have to be unique or may even
be omitted.
The data in segment Bank 10 can be output via the single read read-only code (SF) and
enhanced read read-only code (EF) commands. (see "Single Read Read-Only Code SF" on
page 39 and see "Enhanced Read Read-Only Code EF" on page 39)
Bank 11: User Memory
Segment Bank 11 contains an area to which the user has free access. This size of this area
depends on the chip type, or the area may not be present.
2017-12
The data in segment Bank 11 is addressed via the single read words (SR), single write words
(SW), enhanced read words (ER), and enhanced write words (EW) commands. (see "Single
Read Words SR" on page 42, see "Single Write Words SW" on page 42, see "Enhanced Read
Words ER" on page 42, and see "Enhanced Write Words EW" on page 43)
13
IUH-F190-V1-*, IUT-F190-R4-V1*
Product Description
3.2.4
Electronic Product Code (EPC)
The electronic product code is a unique identifier in the form of a sequence of numbers. The
number sequence has a set structure and a length of 64 bits, 80 bits, 96 bits, or longer
(depending on the EPC Ident number used). This number sequence is saved to the RFID tag,
offering worldwide unique identification of the tagged object.
The system of Electronic Product Codes (EPC) was defined by GS1/EPCglobal for use in
inventory management. Tags with memory banks for EPC codes must be programmed by the
user. The memory of new tags must not contain any valid EPC codes. The EPC numbers are
managed and assigned by GS1. To obtain EPC numbers, please contact the GS1 branch in
your country (http://www.gs1.com/contact).
The electronic product code is defined by EPCglobal with at present 13 different encoding
schemes. SGTIN-96 (serialized global trade item number) is given here as an example of a
frequently used encoding scheme. SGTIN-96 has a defined format, and is structured as
follows:
1. Header: The header specifies the EPC standard used, and denotes the number sequence.
2. Filter value: Denotes the unit of the product, for example, end product, additional packaging, pallet.
3. Partition: Denotes the point at which the following company prefix ends and the object
data begins.
4. Company Prefix: Assigned sequence of numbers that identifies the producer.
5. Object class: Sequence of numbers that describes the object, e.g., item number.
The company prefix and the object class are each of variable length, but together are always 44 bits long.
6. Serial number: Sequence of numbers that identifies the item, e.g., the sequential serial
number of the item.
Header Filter value Partition Company Prefix
Length
Value
3.2.5
8 Bit
3 Bit
3 Bit
48 dez
0 dez
5 dez
Object class
Serial number
20 - 40 Bit
4 - 24 Bit
38 Bit
4050143 dez
124 dez
203886 dez
Influence of various materials on the sensing range
2017-12
In the UHF range, the nature of the surrounding area and the surface to which the transponder
is secured have a serious influence on the range that the system can attain. The UHF
transponder cannot be mounted on metal without requiring adaptations. Glass has a negative
influence on the sensing range when used as a mounting surface. If a UHF transponder is
mounted on damp material, the sensing range is much poorer than the range of a transponder
mounted on dry material. The mounting surface often affects the read range much more than
the material between the transponder and the read/write head. The graph shows the effect of
different materials on the sensing range.
14
IUH-F190-V1-*, IUT-F190-R4-V1*
Product Description
100 %
90 %
80 %
70 %
60 %
50 %
40 %
30 %
20 %
Foam material
Film
Cardboard (dry)
Cardboard (wet)
Wood (dry)
Glass
Metal
10 %
Material
underground
et
al
as
Gl
Ca
Fi
rd
lm
bo
ar
Ca
(d
rd
ry
bo
ar
(w
et
oo
(d
Fo
ry
am
at
er
ial
Ai
0%
Material between transponder and
read / write head
3.2.6
Dense Reader Mode (DRM)
Europe
A special operating mode for read/write tags in accordance with the specification EPC Gen 2
(ISO/IEC 18000-63) allows several read/write heads to be operated close to each other
simultaneously without interference.
In accordance with EN 302208, the read/write head uses only channels 4, 7, 10, and 13 in this
mode for transmission (read/write head
read/write tag communication path). The
transmission power is a maximum of 2 W ERP in accordance with EN 302208.
Werp
2.0
865.0
865.7
866.3
10
866.9
11
12
13
867.5
14
15
Channel
868.0 MHz
2017-12
Figure 3.1
The response from the read/write tag appears via the frequency offset, which is achieved by
the modulation used in this mode on the two adjacent channels. Due to the high level
difference between the transmission channels and the response channels, this technology
offers major benefits for reusing frequencies.
15
IUH-F190-V1-*, IUT-F190-R4-V1*
Product Description
3.2.7
Frequency Hopping Spread Spectrum
With FHSS (Frequency Hopping Spread Spectrum), the information to be transmitted is
distributed successively through multiple channels. Only one frequency channel is used at any
one time. This results in a larger bandwidth for the entire signal, in spite of the fact that each
channel has a smaller bandwidth. In this section the channel assignment for China and the
USA is shown graphically. For both assignments, different parameters apply, such as channel
number and channel bandwidth. Different parameterizations apply in other countries.
China
In China, the frequency range 920 MHz ... 925 MHz is available for UHF-RFID read/write
heads. The range is split into channels, each with a bandwidth of 250 kHz. A maximum of 2
W ERP is permitted on 16 of the available channels. The transmission power is indicated in
W ERP. FHSS is used with a maximum retention time of two seconds. The UHF RFID read/write
head for China uses channel 2 to 17.
Werp
2.0
0.1
920
10
11
12
13
14
15
920.625
16
17
18
19
Channel
924.375 925 MHz
Figure 3.2
United States
The ISM band from 902 MHz ... 928 MHz is available in the USA. The band is split into 50
channels, each with a 500 kHz bandwidth. FHSS with a maximum retention time of 0.4
seconds is used. All channels must be used. Channel restriction is not permitted.
In contrast to the read/write heads for Europe and China, the transmission power is indicated in
Weirp. A maximum of 4 Weirp is permitted on all channels.
Weirp
4.0
0.2
902.75
10
15
20
25
30
35
40
45
50 Channel
927.25 MHz
2017-12
Figure 3.3
16
IUH-F190-V1-*, IUT-F190-R4-V1*
Product Description
3.2.8
Relevant Standards for UHF
European radio standards: EN 300220 and EN 302208
Usage recommendations for RFID type labels, information about recycling, installation of
readers and antennae: ISO/IEC TR 24729 parts 1-4
Installation and commissioning of UHF-RFID systems: ETSI TR 102436
Description of air interface: EPC Gen 2 (ISO/IEC 18000-63)
3.3
Countries of Use
Note!
Transmission License
A country-specific transmission license is required to operate the read/write head. In the
European Union, the manufacturer's declaration of conformity constitutes an adequate license.
All currently valid transmission licenses can be found in the datasheet for the respective
read/write head at www.pepperl-fuchs.com.
Note!
Country Identifier
All read/write heads operate within their maximum frequency range with the appropriate
settings for the relevant country. The country-specific settings are configured during production
and cannot be subsequently modified.
Note!
If you wish to use the read/write head in a country not included in this chapter, make sure the
relevant values for the read/write head are consistent with the local conditions before use.
The frequency access procedure used is part of the country-specific settings.
Frequency Access Method
3.3.1
■
In many countries, including the USA and China, a frequency hopping spread spectrum is
used. See chapter 3.2.7. The number and position of the frequencies is fixed and cannot
be changed by the user. All channels are used.
■
A programmable frequency list is used in other countries, including the European Union,
Singapore, Vietnam, and India. You can compile this frequency list from a specified set of
channels. Four channels are specified in the European Union as appropriate for dense
reader mode in accordance with EN 302208. See chapter 3.2.6. With this setting, you can
configure one, multiple, or all four channels.
European Union
2017-12
In the European Union, the use of RFID in the UHF range is regulated by EN 302208.
■
UHF wavelength: 865 MHz
868 MHz
■
Radiated power: 3 mW
■
Channel bandwidth: 200 kHz
■
Channel spacing: 600 kHz
■
Frequency access method: programmable frequency list
■
Number of predefined channels: 4
Programmable channels: 4, 7, 10, 13
Center frequencies: 865.7 MHz, 866.3 MHz, 866.9 MHz, 867.5 MHz
Up to 4 channels can be parameterized and used in sequence.
Default: dense reader mode with channel 4, 10, 7, 13. See chapter 3.2.6.
1000 W ERP; Default = 50 mW ERP
17
IUH-F190-V1-*, IUT-F190-R4-V1*
Product Description
3.3.2
Argentina
The regulations for the UHF frequency range in Argentina are the same as the regulations for
the UHF frequency range in the USA. See chapter 3.3.18.
3.3.3
Australia
In Australia, the use of RFID in the UHF range is regulated as follows:
■
UHF wavelength: 920 MHz ... 926 MHz
■
Radiated Power: 3
■
Channel bandwidth: 500 kHz
■
Channel spacing: 500 kHz
■
Frequency access method: frequency hopping spread spectrum. See chapter 3.2.7.
■
Number of channels: 12
1250 mW EIRP; Default = 125 mW EIRP
Channels used: 1, 2, 3, ... 12
Center frequencies: 919.75 MHz + (M x 0.5) MHz
All 12 channels are always used.
3.3.4
Brazil
In Brazil, the use of RFID in the UHF range is regulated as follows:
■
UHF wavelength: 915 MHz
928 MHz
■
Radiated Power: 3
■
Channel bandwidth: 250 kHz
■
Channel spacing: 250 kHz
■
Frequency access method: frequency hopping spread spectrum. See chapter 3.2.7.
■
Number of channels: 52
1250 mW EIRP; Default = 125 mW EIRP
Channels used: 1, 2, 3, ... 52
Center frequencies: 914.875 MHz + (M x 0.25) MHz
All 52 channels are always used.
3.3.5
Canada
The regulations for the UHF frequency range in Canada meet the requirements for the UHF
frequency range in the U.S.. See chapter 3.3.18.
3.3.6
China
In China, the use of RFID in the UHF range is regulated by the provisions of the China Ministry
of Industry and Information Technology (CMIIT).
■
UHF wavelength: 920 MHz ... 925 MHz
■
Radiated Power: 3
■
Channel bandwidth: 250 kHz
■
Channel spacing: 250 kHz
■
Frequency access method: frequency hopping spread spectrum (China). See chapter
3.2.7.
2017-12
800 mW ERP; Default = 80 mW ERP
18
IUH-F190-V1-*, IUT-F190-R4-V1*
Product Description
■
Number of channels: 16
Channels used: 2, 3, 4, ... 17
Center frequencies: 920.125 MHz + (M x 0.25) MHz
All 16 channels are always used.
3.3.7
Hong Kong
The regulations for the UHF frequency range of 865 MHz to 868 MHz in Hong Kong are the
same as the regulations for the UHF frequency range in the European Union. See chapter
3.3.1.
The regulations for the UHF frequency range of 920 MHz to 925 MHz in Hong Kong are the
same as the regulations for the UHF frequency range in Thailand. See chapter 3.3.17.
3.3.8
India
In India, the use of RFID in the UHF range is regulated in accordance with EN 302208.
■
UHF wavelength: 865 MHz
867 MHz
■
Radiated Power: 3
■
Channel bandwidth: 200 kHz
■
Channel spacing: 200 kHz
■
Frequency access method: programmable frequency list
■
Number of predefined channels: 10
800 mW ERP ; Default = 50 mW ERP
Programmable channels: 1, 2, 3, ... 10
Center frequencies: 865.1 MHz, 865.3 MHz, 865.5 MHz, 865.7 MHz, 865.9 MHz,
866.1 MHz, 866.3 MHz, 866.5 MHz, 866.7 MHz, 866.9 MHz
Up to ten channels can be parameterized and used in sequence.
Default: dense reader mode on channel 1, 7, 4, 10. See chapter 3.2.6.
3.3.9
Japan
In Japan, the use of RFID in the UHF range is regulated as follows:
■
UHF wavelength: 916.7 MHz
920.5 MHz
■
Radiated Power: 3
■
Channel bandwidth: 200 kHz
■
Channel spacing: 1200 kHz
■
Frequency access method: programmable frequency list.
■
Number of predefined channels: 4
1250 mW EIRP ; Default = 125 mW EIRP
Programmable channels: 5, 11, 17, 23
Center frequencies: 916.8 MHz, 918.0 MHz, 919.2 MHz, 920.4 MHz
Up to four channels can be parameterized and used in sequence.
Default: dense reader mode on channel 5, 17, 11, 23. See chapter 3.2.6.
3.3.10
Colombia
The regulations for the UHF frequency range in Colombia are the same as the regulations for
the UHF frequency range in the USA. See chapter 3.3.18.
2017-12
3.3.11
Malaysia
In Malaysia, the use of RFID in the UHF range is regulated as follows:
19
IUH-F190-V1-*, IUT-F190-R4-V1*
Product Description
■
UHF wavelength: 919 MHz
923 MHz
■
Radiated Power: 3
■
Channel bandwidth: 500 kHz
■
Channel spacing: 500 kHz
■
Frequency access method: frequency hopping spread spectrum. See chapter 3.2.7.
■
Number of channels: 8
800 mW ERP; Default = 80 mW ERP
Channels used: 1, 2, 3, ... 8
Center frequencies: 918.75 MHz + (M x 0.5) MHz
All 8 channels are always used.
3.3.12
Mexico
The regulations for the UHF frequency range in Mexico meet the requirements for the UHF
frequency range in the U.S.. See chapter 3.3.18.
3.3.13
New Zealand
In New Zealand, the use of RFID in the UHF range is regulated as follows:
■
UHF wavelength: 921.5 MHz
928 MHz
■
Radiated Power: 3
■
Channel bandwidth: 500 kHz
■
Channel spacing: 500 kHz
■
Frequency access method: frequency hopping spread spectrum. See chapter 3.2.7.
■
Number of channels: 13
1250 mW EIRP; Default = 125 mW EIRP
Channels used: 1, 2, 3, ... 13
Center frequencies: 921.25 MHz + (M x 0.5) MHz
All 13 channels are always used.
3.3.14
Russia
In Russia, the use of RFID in the UHF range is regulated in accordance with EN 302208:
■
UHF wavelength: 866 MHz
867.6 MHz
■
Radiated Power: 3
■
Channel bandwidth: 200 kHz
■
Channel spacing: 200 kHz
■
Frequency access method: programmable frequency list.
■
Number of predefined channels: 8
800 mW ERP; Default = 50 mW ERP
Programmable channels: 1, 2, 3, ... 8
Center frequencies: 866.1 MHz, 866.3 MHz, 866.5 MHz, 866.7 MHz, 866.9 MHz,
867.1 MHz, 867.3 MHz, 867.5 MHz
Up to eight channels can be parameterized and used in sequence.
Default: dense reader mode on channel 1, 7, 4. See chapter 3.2.6.
Singapore
In Singapore, the use of RFID in the UHF range of 866 MHz to 868 MHz is regulated in
accordance with EN 302208.
20
2017-12
3.3.15
IUH-F190-V1-*, IUT-F190-R4-V1*
Product Description
■
UHF wavelength: 866 MHz
868 MHz
■
Radiated Power: 3
■
Channel bandwidth: 200 kHz
■
Channel spacing: 200 kHz
■
Frequency access method: programmable frequency list
■
Number of predefined channels: 10
500 mW ERP ; Default = 50 mW ERP
Programmable channels: 1, 2, 3, ... 10
Center frequencies: 866.1 MHz, 866.3 MHz, 866.5 MHz, 866.7 MHz, 866.9 MHz,
867.1 MHz, 867.3 MHz, 867.5 MHz, 867.7 MHz, 867.9 MHz
Up to ten channels can be parameterized and used in sequence.
Default: dense reader mode on channel 1, 7, 4, 10. See chapter 3.2.6.
In Singapore, the use of RFID in the UHF range of 920 MHz to 925 MHz is regulated as follows.
■
UHF wavelength: 920 MHz ... 925 MHz
■
Radiated Power: 3
■
Channel bandwidth: 500 kHz
■
Channel spacing: 500 kHz
■
Frequency access method: frequency hopping spread spectrum. See chapter 3.2.7.
■
Number of channels: 10
800 mW ERP ; Default = 80 mW ERP
Channels used: 1, 2, 3, ... 10
Center frequencies: 919.75 MHz + (M x 0.5) MHz
All 10 channels are always used.
3.3.16
South Korea
In South Korea, the use of RFID in the UHF range is regulated as follows:
■
UHF wavelength: 917.2 MHz
920.4 MHz
■
Radiated Power: 3
■
Channel bandwidth: 200 kHz
■
Channel spacing: 600 kHz
■
Frequency access method: frequency hopping spread spectrum. See chapter 3.2.7.
■
Number of channels: 6
1250 mW EIRP ; Default = 125 mW EIRP
Channels used: 1, 4, 7, 10, 13, 16
Center frequencies: 917.1 MHz + (M x 0.20) MHz
All 6 channels are always used.
3.3.17
Thailand
2017-12
In Thailand, the use of RFID in the UHF range is regulated as follows:
■
UHF wavelength: 920 MHz ... 925 MHz
■
Radiated Power: 3
■
Channel bandwidth: 500 kHz
■
Channel spacing: 500 kHz
■
Frequency access method: frequency hopping spread spectrum. See chapter 3.2.7.
1250 mW EIRP ; Default = 125 mW EIRP
21
IUH-F190-V1-*, IUT-F190-R4-V1*
Product Description
■
Number of channels: 10
Channels used: 1, 2, 3, ... 10
Center frequencies: 919.75 MHz + (M x 0.5) MHz
All 10 channels are always used.
3.3.18
United States of America
In the USA, the use of RFID in the UHF range is regulated in accordance with the provisions set
out by the Federal Communications Commission (FCC).
■
UHF wavelength: 902 MHz
928 MHz
■
Radiated Power: 3
■
Channel bandwidth: 500 kHz
■
Channel spacing: 500 kHz
■
Frequency access method: frequency hopping spread spectrum (USA). See chapter
3.2.7.
■
Number of channels: 50
1250 mW EIRP ; Default = 125 mW EIRP
Channels used: 1, 2, 3, ... 50
Center frequencies: 902.25 MHz + (M x 0.5) MHz
All 50 channels are always used.
3.3.19
Vietnam
In Vietnam, the use of RFID in the UHF range of 866 MHz to 868 MHz is regulated in
accordance with EN 302208.
■
UHF wavelength: 866 MHz
868 MHz
■
Radiated Power: 3
■
Channel bandwidth: 200 kHz
■
Channel spacing: 200 kHz
■
Frequency access method: programmable frequency list
■
Number of predefined channels: 10
500 mW ERP; Default = 50 mW ERP
Programmable channels: 1, 2, 3, ... 10
Center frequencies: 866.1 MHz, 866.3 MHz, 866.5 MHz, 866.7 MHz, 866.9 MHz,
867.1 MHz, 867.3 MHz, 867.5 MHz, 867.7 MHz, 867.9 MHz
Up to ten channels can be parameterized and used in sequence.
Default: dense reader mode on channel 1, 7, 4, 10. See chapter 3.2.6.
2017-12
The regulations for the UHF frequency range of 920 MHz to 925 MHz in Vietnam are the same
as the regulations for the UHF frequency range in Singapore. See chapter 3.3.15.
22
IUH-F190-V1-*, IUT-F190-R4-V1*
Product Description
3.4
General Functions and Features
Figure 3.4
Functions
The read/write heads were developed for reading and writing passive read/write tags with a
UHF range operating frequency.
Read/write head IUH-F190-V1-* can only be used together with an IDENTControl control
interface from Pepperl+Fuchs.
Read/write heads IUT-F190-R4-V1-* do not require a control interface and can be connected
by means of a point-to-point connection to a RS-485 serial interface.
Detection range
The detection range is typically 2 meters. Tags that comply with EPC Gen 2 (ISO/IEC 1800063) are supported.
Maximum Frequency Range
Read/write heads IUH-F190-V1-FR1* and IUT-F190-R4-V1-FR1* can be operated in the
frequency range from 865 MHz to 868 MHz. Read/write heads IUH-F190-V1-FR2* and IUTF190-R4-V1-FR2* can be operated in the frequency range from 902 MHz to 928 MHz.
Features
The read/write head has the following features:
■
3 function indicator LEDs
■
Industrial housing with a compact design
■
Bulk detection
■
Connects to IDENT via connector V1 (M12 x 1)Control
■
Protected against electrostatic discharge
Integrated antenna
2017-12
The read/write heads have a linear dual polarized antenna. The read/write heads can transmit
and receive waves with horizontal and vertical polarization.
23
IUH-F190-V1-*, IUT-F190-R4-V1*
Product Description
3.5
Indicators and Operating Elements
The read/write head has 3 LEDs, which are green/blue/yellow. The various indicators denote:
3.6
■
Green LED: Power on
■
Blue LED: Transmission mode
■
Yellow LED: Read/write operation successful
Connection
IUH-F190-V1-*
The IUH-F190-V1-* read/write head is connected to the IDENTControl control interface via the
M12 x 1 connector.
do not connect
Shield
Figure 3.5
IUT-F190-R4-V1-*
The IUT-F190-R4-V1-* read/write head is connected to an RS-485 serial interface of the parent
device via the M12 x 1 connector via a point-to-point connection. The read/write head has an
internal terminator on the RS-485 interface. For this reason, only one read/write head is
provided within an RS-485 network. It is not possible to build an RS-485 network with multiple
read/write heads. The factory-set transfer rate of the interface is 38,400 bit/s.
Caution!
Power Supply
The IUT-F190-R4-V1-* read/write head must only be connected to a current source with limited
power according to EN 60950.
The connection cable of the IUT F190-R4-V1-* read/write head must be no longer than 3 m.
Ground connection
The ground connection of the read/write head is positioned on the right-hand side when
viewed from the front, if the cable outlet is facing downward. The ground conductor is screwed
to the housing with a crimp connector. In order to guarantee safe grounding, mount the
serrated washer between the crimp connectors and the housing.
24
Housing
Serrated lock washer
Crimp connector
Lock screw
2017-12
IUH-F190-V1-*, IUT-F190-R4-V1*
Product Description
Use a ground conductor lead with a cross-section of at least 4 mm2.
Tighten the retaining bolt to a tightening torque of 1.6 Nm ± 0.4 Nm.
3.7
Scope of Delivery
■
Read/write head
■
Quick start guide
3.8
Accessories
3.8.1
IDENTControl
The IUH-F190-V1-* read/write head can be connected to Pepperl+Fuchs IDENTControl control
interfaces.
Interface
Designation
4 read/write heads:
Ethernet
IC-KP-B17-AIDA1
2 read/write heads:
PROFIBUS
IC-KP2-2HB6-V15B
Ethernet
IC-KP2-2HB17-2V1D
EtherCAT
IC-KP2-2HB21-2V1D
Serial
IC-KP2-2HRX-2V1
1 read/write head:
PROFIBUS
IC-KP2-1HB6-V15B
IC-KP2-1HB6-2V15B
Ethernet
IC-KP2-1HB17-2V1D
Serial
IC-KP2-1HRX-2V1
2017-12
Table 3.1
25
IUH-F190-V1-*, IUT-F190-R4-V1*
Product Description
3.8.2
Read/Write Tags
Type
Designation
EPC Gen 2 (ISO/IEC 18000-63)
IUC72-F152-M-FR1
IUC72-F152-M-FR2
IUC76-50-FR1
IUC76-50-FR2
IUC76-F157-M-FR1
IUC76-F157-M-FR2
IUC76-F203-M-FR1
IUC76-F203-M-FR2
IUC76-C8-T14-GBL
IUC77-F151-M-GBL
IUC77-25L100-GBL
IUC77-25L110-GBL
Table 3.2
3.8.3
Connection cable for R/W heads and trigger sensors
Compatible connection cables with shielding are available for connecting the R/W heads and
trigger sensors.
Figure 3.6
Description
2 m long (straight female, angled male)
V1-G-2M-PUR-ABG-V1-W
5 m long (straight female, angled male)
V1-G-5M-PUR-ABG-V1-W
10 m long (straight female, angled male)
V1-G-10M-PUR-ABG-V1-W
20 m long (straight female, angled male)
V1-G-20M-PUR-ABG-V1-W
Field attachable female connector, straight, shielded
V1-G-ABG-PG9
Field attachable male connector, straight, shielded
V1S-G-ABG-PG9
Field attachable female connector, angled, shielded
V1-W-ABG-PG9
Field attachable male connector, angled, shielded
V1S-W-ABG-PG9
Dummy plug M12x1
VAZ-V1-B3
2017-12
Accessories
26
IUH-F190-V1-*, IUT-F190-R4-V1*
Product Description
3.8.4
Cable connectors for the power supply
Compatible M12 sockets with an open cable end for connecting the IDENTControl to a power
supply are available in different lengths.
Figure 3.7
3.8.5
Accessories
Designation
Length 2 m (straight socket)
V1-G-2M-PUR
Length 5 m (straight socket)
V1-G-5M-PUR
Length 10 m (straight socket)
V1-G-10M-PUR
Mounting set
Multiple mounting brackets are available to mount the read/write head on the wall or on a pipe.
Designation
Mounting bracket for wall and pipe mounting
IUZ-MH12
Mounting bracket for wall mounting
IUZ-MH13
Mounting bracket for pipe mounting
IUZ-MH15
2017-12
Accessories
27
IUH-F190-V1-*, IUT-F190-R4-V1*
Installation
Installation
4.1
Storage and transport
For storage and transport purposes, package the unit using shockproof packaging material
and protect it against moisture. The best method of protection is to package the unit using the
original packaging. Furthermore, ensure that the ambient conditions are within allowable range.
4.2
Unpacking
Check the product for damage while unpacking. In the event of damage to the product, inform
the post office or parcel service and notify the supplier.
Check the package contents against your purchase order and the shipping documents for:
■
Delivery quantity
■
Device type and version in accordance with the type label
■
Any accessories ordered
Retain the original packaging in case you have to store or ship the device again at a later date.
Should you have any questions, please contact Pepperl+Fuchs.
4.3
Mounting
Warning!
Malfunctions with pacemakers
This device does not exceed the permissible limits for electromagnetic fields. Maintain a
minimum distance of 25 cm between the device and your pacemaker.
Inadequate distance from the read/write head can result in inhibitions, reprogramming, or
incorrect stimulation pulses.
Warning!
Hot surfaces
Be careful not to burn your fingers when handling the device! After shutting down the device,
wait at least half an hour before handling the device.
The read/write head is intended for wall mounting or mounting on brackets in internal areas.
Please mount the read/write head using only the holes provided in the housing. The preferred
mounting direction is with the cable connection facing vertically downwards.
Note!
Do not route the connection cable in the detection range of the antenna.
To attach the read/write head, use 3 screws with a diameter of 4 mm, as well as mounting
materials that are suitable for the type of mounting surface. The tightening torque of the screws
depends on the type of mounting.
Caution!
Mounting the read/write head
Make sure that the read/write head is firmly attached to the mounting surface.
The installation recommendations made in this document are based on favorable conditions.
Pepperl+Fuchs GmbH provides no guarantee of correct function in cross environments.
28
2017-12
Note!
IUH-F190-V1-*, IUT-F190-R4-V1*
Installation
Mounting the read/write head
Figure 4.1
4.3.1
Room Orientation
2017-12
The alignment of the read/write tag antennae in relation to the antennae of the read/write head
influences the detection range of the system. Make sure the antennae are aligned parallel to
each other.
Read/write head
Tag
Optimum alignment of the tag
■ Good communication between the
read/write head and tag
Poor alignment of the tag
■ Insufficient communication between the
read/write head and tag
29
IUH-F190-V1-*, IUT-F190-R4-V1*
Installation
4.3.2
Minimum Distances
When positioning the read/write head, please observe the minimum distances. The lateral
distance between the read/write head and metals or liquids should be at least 50 cm. The
distance between the read/write head and the ground should be at least 50 cm.
min. 50 cm
Read / write
head
min. 50 cm
metal support
Figure 4.2
During simultaneous operation of several read/write heads, only one read/write head may ever
communicate with a tag at any given time. When arranging the read/write heads, make sure
that the measurement ranges do not overlap. You can enlarge or reduce the size of the
measurement range by changing the transmitting power. Determine the measurement range of
each read/write head at the mounting location.
Note!
During mounting, take into account how the read/write heads may cause interference with each
other. The further the transmission channels of the read/write heads are from each other, the
lower the risk of interference.
If you want to transmit with just one read/write head at any given time, use the multiplex mode
of the IDENTControl control interface. Multiplex operating mode allows chronologically
exclusive access to tags, and prevents mutual interference from read/write heads. For a precise
description, see the manual for your control interface.
4.3.3
Polarization
The polarization of the electromagnetic wave emitted by an antenna depends on the type of
antenna and is defined for the electromagnetic field component of the electromagnetic wave.
Polarization can be either linear or circular. In the case of an electromagnetic wave with linear
polarization, the direction of the vector of the electromagnetic field component is spatially
constant and therefore dependent on the position of the antenna. Linear polarization can be
either vertical or horizontal.
2017-12
To achieve the maximum detection range for a UHF system, the polarization of the read/write
head must match the polarization of the tag so that both have the same spatial orientation.
Refer to the relevant data sheet to find the polarization of the tag.
30
IUH-F190-V1-*, IUT-F190-R4-V1*
Installation
The integrated antenna of the read/write head has dual linear polarization. The read/write head
operates in combined mode by default. In combined mode, both horizontal and vertical
polarization are used for each read/write access. This increases the reading reliability of tags
with an unknown location in the room.
If the orientation of the tags is known, you can optimize the access time by setting a fixed
polarization. To do this, you can switch the polarization to horizontally linear polarization or
vertically linear polarization in the software. The linear polarization plane refers to the preferred
mounting direction with the cable connection mounted vertically downwards.
Figure 4.3
= Vertical polarization plane
2 = Horizontal polarization plane
4.4
Connection
Connect the IUH-F190-V1-* read/write head to the IDENTControl control interface using a
shielded cordset (see chapter 3.8.3). Ensure that the shield fully encapsulates the connection
cable to avoid EMC interference. (see chapter 4.5)
Connect the IUT-F190-R4-V1-* read/write head to the higher level control unit using a shielded
cordset. Ensure that the shield is fully encapsulating so that interference is dissipated via the
protective earth connections to avoid EMC disturbances.
Warning!
Incorrect electrical connection
Damage to the device or plant caused by incorrect electrical connection.
Check all connections in the plant before commissioning the device.
After connecting the supply voltage, the POWER LED on the device lights up green. If the LED
does not light up on the device, the power supply is not connected correctly.
Caution!
Power Supply
The IUT F190-R4-V1-* read/write head must only be connected to a current source with limited
power according to EN 60950.
2017-12
The connection cable of the IUT F190-R4-V1-* read/write head must be no longer than 3 m.
31
IUH-F190-V1-*, IUT-F190-R4-V1*
Installation
4.5
EMC Concept
The outstanding noise immunity of the IDENTControl against emission and immission is based
on its consistent shielding design, which uses the principle of the Faraday cage. Interference is
caught in the shield and safely diverted via the ground connections.
write head
IDENTControl
INTERBUS
Control
The cable shielding is used to discharge electromagnetic interference. When shielding a cable,
you must connect both sides of the shield to ground with low resistance and low inductance.
Note!
If cables with double shields are used, e.g. wire mesh and metalized foil, the both shields must
be connected together, with low resistance, at the ends when making up the cable.
Power supply cables are the source of much interference, e.g. from the supply lines of 3-phase
electric motors. For this reason, the parallel laying of power supply cables with data and signal
cables should be avoided, particularly in the same cable duct.
Note!
2017-12
The circuit ground is conductively connected to the housing of the write/read head and to the
protective ground. (Connection image
see Figure 3.5 on page 24)
32
IUH-F190-V1-*, IUT-F190-R4-V1*
Commissioning
Commissioning
5.1
Definitions
5.1.1
Display
Angle brackets contain the abbreviated meaning of a command structure, e.g.,
The index hex or .xx denotes a hexadecimal number.
hex ASCII denotes a value in the hexadecimal system, specified in ASCII characters.
Example: 10dec corresponds to Ahex; A ASCII corresponds to 41hex. see chapter 9.2
5.1.2
Legend
:
IDENTControl channel
:
1 byte, 8-bit check sum with the addition of all preceding characters,
without overflow
:
Data with the size multiplied by 4 bytes
:
Length of the data specified to a command, 2 characters binary,
HighByte, LowByte
eirp:
equivalent isotropically radiated power
erp:
effective radiated power
:
1 byte = 03hex
:
TID, 4 bytes + an optional 4 or 8 bytes
:
Length of the data in bytes, 2 bytes
Use in multiframe protocol
1 character hex ASCII = number of data bytes
Permitted values in the read/write head IUH*: 2, 4, 6, 8, A, C, E
:
Length of the UII in bytes, 2 bytes
Use in multiframe protocol
: Links several filters; OR = 0; AND = 1
If one filter only is used, this value is ignored
:
Mask specification
:
Mask length in bits, values: 00
:
Number of the memory bank (see parameter MB)
:
Parameter type, 2 bytes, or 2 ASCII characters
:
Negates the mask comparison; not negated = 0; negated = 1
:
Protocol control word according to EPC Gen 2 (ISO/IEC 18000-63), 2
bytes, describes characteristics such as the length of the UI/EPC
:
&
:
1 ASCII character (see chapter 6.8)
:
Start address in the selected memory bank in bits, values:
0000 FFFF
:
= U (for read/write head IUH*)
:
2 ASCII characters
:
Unique Item Identifier, memory area of a tag in accordance with EPC
Gen 2 (ISO/IEC 18000-63), in which the EPC code is stored
2017-12
FF
33
IUH-F190-V1-*, IUT-F190-R4-V1*
Commissioning
5.2
:
Word start address in the read/write tag, 4 hex ASCII characters, range
from "0000h" to "FFFF", depending on tag type
:
Number of words to be read or written, 2 hexASCII characters. Range
from "01" through "20" depending on the tag type, word lengths are 4
bytes
Sensor Settings
Warning!
Device not configured or configured incorrectly
Configure the device prior to commissioning. A device that has not been configured or
configured incorrectly may lead to faults in the plant.
You must configure the control interface before commissioning the IUH-F190-V1-* read/write
head. To do so, refer to the "Commissioning" chapter of the manual for your control interface.
Configure the read/write heads with the described system commands (see chapter 6.6.1). For
a parameterization example, see see chapter 5.3.
Caution!
Uncontrolled triggered processes
Before commissioning the device, make sure that all processes are running smoothly;
otherwise damage may occur in the plant.
5.3
Operation via the Command Interface
This section shows you how to commission the IUH-F190-V1-* read/write head using an
IDENTControl control interface with serial interface. The commissioning procedure described
relates to the RS-232 interface and involves a PC. The examples include the syntax for coding
the commands and parameters via the Ethernet TCP/IP and PROFIBUS/PROFINET
interfaces. Further details about these codes and the factory settings for your IDENTControl
control interface can be found in the corresponding manual.
The commissioning of the IUT-F190-R4-V1-* read/write head with integrated RS-485 interface
is also carried out using the above commands and parameters. For details regarding the IUT
F190-R4-V1-* read/write head see chapter 6.7
Example:
In the examples below, the read/write head is connected to channel 1 of the control interface.
The outputs follow the multiframe protocol, see table "Responses Depending on Protocol
Mode QV" on page 56.
Reading Tags
Enhanced Read Read-Only Code
Send the enhanced read read-only code command to the read/write head. The "RF ON" LED
on the read/write head lights up blue.
Serial
Ethernet
PROFIBUS/PROFINET
Command:
EF1
.00.04.1D.03
.1D.03
Confirmation:
.00.06.1D.03.FF.0B
.1D.03.FF.0B
Response:
.35.31
.00.06.1D.03.05.0C
.1D.03.05.0C
Enhanced read read-only code, no tag in the detection range
2017-12
Table 5.1
34
IUH-F190-V1-*, IUT-F190-R4-V1*
Commissioning
Move a tag into the read/write head's detection range. When the tag has been detected and the
read-only code has been read out, the "READ / WRITE" LED on the read/write head lights up
yellow. The read-only code is displayed in the terminal program.
Response:
Table 5.2
Serial
Ethernet
PROFIBUS/PROFINET
.30.31.00.0E.30.
00.30.14.F7.33.7
C.00.1F.00.00.00
.00.01.00.08.E2.
00.60.03.14.42.D
6.D1
.00.20.1D.03.00.0D.00.0E.
30.00.30.14.F7.33.7C.00.1
F.00.00.00.00.01.00.08.E2
.00.60.03.14.42.D6.D1
.1D.03.00.0D.00.0E.30.00.
30.14.F7.33.7C.00.1F.00.0
0.00.00.01.00.08.E2.00.60
.03.14.42.D6.D1
Enhanced read read-only code, tag is entering the detection range
Describing Tags
Single Write Special Read-Only Code
Send the single write special read-only code command to the read/write head while a tag is in
the detection range. See "Single Write Special Read-Only Code SP" on page 41 and see
chapter 3.2.4.
Serial
Ethernet
PROFIBUS/PROFINET
Command:
SP1E.30.00.30.1 .00.14.0D.E3.00.00.30.00. .0D.E3.00.00.30.00.30.14.
4.F7.33.7C.00.1F 30.14.F7.33.7C.00.1F.00.0 F7.33.7C.00.1F.00.00.03.1
.00.00.03.1C.6E 0.03.1C.6E
C.6E
Confirmation:
.00.06.0D.E3.FF.2D
.0D.E3.FF.2D
Response:
.30.31.00.0E.30.
00.30.14.F7.33.7
C.00.1F.00.00.03
.1C.6E
.46.31.30.30.30.3
.00.16.0D.03.00.2E.00.0E.
30.00.30.14.F7.33.7C.00.1
F.00.00.03.1C.6E
.00.0A.0D.03.0F.2F.30.30.
30.31
0D.03.00.2E.00.0E.30.00.
30.14.F7.33.7C.00.1F.00.0
0.03.1C.6E
.0D.03.0F.2F.30.30.30.31
Single Read Special Read-Only Code
As confirmation, read out the read-only code of the tag within the read/write head's detection
range via the single read special read-only code command. See "Single Read Special ReadOnly Code SS" on page 40.
Ethernet
PROFIBUS/PROFINET
Command:
SS10
.00.04.0A.02
.0A.02
Confirmation:
.00.06.0A.02.FF.30
.0A.02.FF.30
Response:
.30.31.00.0E.30.
00.30.14.F7.33.7
C.00.1F.00.00.03
.1C.6E
.46.31.30.30.30.3
.00.16.0A.02.00.31.00.0E.
30.00.30.14.F7.33.7C.00.1
F.00.00.03.1C.6E
.00.0A.0A.02.0F.32.30.30.
30.31
.0A.02.00.31.00.0E.30.00.
30.14.F7.33.7C.00.1F.00.0
0.03.1C.6E
.0A.02.0F.32.30.30.30.31
2017-12
Serial
35
IUH-F190-V1-*, IUT-F190-R4-V1*
Commissioning
Parameterizing the Read/Write Head
Requesting and Setting the Transmission Power
Read out the read/write head's transmission power with the read parameter PT command:
Serial
Ethernet
PROFIBUS/PROFINET
Command:
RP1UPT.00.00
.00.0A.BE.03.00.55.50.54. .BE.03.00.55.50.54.00.00
00.00
Confirmation:
.00.06.BE.03.FF.33
Response:
.30.31.00.32
.00.0A.BE.03.00.34.00.02. .BE.03.00.34.00.02.00.32
00.32
.BE.03.FF.33
The read/write head's set transmission power is 50 mW (32 hex corresponding to 50 dec).
Change the transmission power of the read/write head to 100 mW (100 dec corresponding to
64hex ) via the write parameter PT command:
Serial
Ethernet
PROFIBUS/PROFINET
WP1UPT.00.02.0 .00.0C.BF.03.00.55.50.54. .BF.03.00.55.50.54.04.00.
0.64
00.02.00.64
02.00.64
Confirmation:
.00.06.BF.03.FF.35
.BF.03.FF.35
Response:
.30.31
.00.06.BF.03.00.36
.BF.03.00.36
2017-12
Command:
36
IUH-F190-V1-*, IUT-F190-R4-V1*
Operation
Operation
6.1
General
The sections below contain information about the commands that relate to your read/write
head. The commands are described using the example of an IDENTControl control interface
with serial interface. All other generally applicable commands and error messages or status
messages can be found in the manual for your IDENTControl control interface.
Warning!
Hot surfaces
Be careful not to burn your fingers when handling the device! After shutting down the device,
wait at least half an hour before handling the device.
Commissioning of the IUT-F190-R4-V1-* read/write head with integrated RS-485 interface is
also carried out using the commands and parameters described. For details regarding the IUT
F190-R4-V1-* read/write head see chapter 6.7
6.2
Basic Command Process
Interference Due to Multipath Propagation
The electromagnetic waves radiated by the read/write head do not just follow the direct route to
the tag, but are also reflected off objects in the vicinity, meaning that multiple partial waves
overlap with the waves radiated by the read/write head.
This overlap causes interference (i.e., exaggeration and dampening of the reception field
strength), leading to almost complete degradation. Depending on the environment, several
reflections may occur with differing intensity and distance. These different reflections lead to a
field strength in the measurement range that is difficult to predict. In the areas of degradation,
the prevailing field strength is weaker than the minimum detection field strength of the tag. As a
result, the tag cannot be activated for communication. Exaggeration of the field strength may
lead to unwanted excessive detection ranges.
1. Detection range
2. Degradation
2017-12
3. Excessive detection ranges
37
IUH-F190-V1-*, IUT-F190-R4-V1*
Operation
The reflections and the resulting spatial inhomogeneity of the field strength depend on the
frequency used. The absolute value of the field strength depends on the transmission power.
Since the tags move in the measurement range of the read/write head, and the environment
can change, it is advisable to repeat the commands at different transmission frequencies and
at varying power. Different transmission frequencies are advisable, since the manufacturing
tolerances and the immediate environment of the tag have an effect on the tag's resonance
frequency.
Several Tags in the Measurement Range
Each read or write command can access one, several, or all tags in a measurement range. The
process is controlled by filter masks, which are managed via the commands Set Filter Mask
(FI) and Activate/Deactivate Filter (MF). These commands allow you to detect specific tags in
the measurement range. see chapter 6.5.
Read Algorithm
To communicate with tags with the maximum possible probability, the read/write head uses an
algorithm that varies the transmitting power and frequency. You can set the corresponding
values for this algorithm via the parameters Power Transmit (PT), Channel Frequency (CD), or
Number of Channels (NC) for the frequency hopping spread spectrum, and Number of
Attempts (TA). The number of set attempts is executed for each pairing of power and
frequency. This process takes a long time, but leads to a high read/write rate. The algorithm
runs through all combinations because it may be the case that a tag can be detected only by
one specific combination of power and frequency. This applies when the read/write head uses
a programmable frequency list as the frequency access method. This frequency list is defined
by parameter CD.
If the country identifier specifies a frequency hopping spread spectrum, the channels defined
there are used. This is not influenced by the programmable frequency list. You can adjust the
number of channels used for each attempt via the Number of Channels parameter (NC).
With the parameter Search Algorithm Cancellation Criteria (NT), you can specify the number of
tags to be processed. If you know the number of tags in the measurement range, you can use
this total number as the value for parameter NT. If the number of tags found corresponds to or
exceeds the value defined in parameter NT, the algorithm cancels any further runs to save time.
Tip
If analysis of a specific application shows that a particular frequency and transmission power
are sufficient to execute commands successfully, the parameters can be set accordingly,
subject to national legislation. This measure reduces the processing time.
6.3
Command Overview
The commands in the list are described in detail on the following pages.
Read/Write Commands
Abbreviation Command description
See "Single Read Read-Only Code SF" on page 39
EF
See "Enhanced Read Read-Only Code EF" on page 39
SS
See "Single Read Special Read-Only Code SS" on page 40
ES
See "Enhanced Read Special Read-Only Code ES" on page 40
SP
See "Single Write Special Read-Only Code SP" on page 41
SR, #SR
See "Single Read Words SR" on page 42
ER, #ER
See "Enhanced Read Words ER" on page 42
SW, #SW
See "Single Write Words SW" on page 42
2017-12
SF
38
IUH-F190-V1-*, IUT-F190-R4-V1*
Operation
Abbreviation Command description
EW, #EW
See "Enhanced Write Words EW" on page 43
KI
See "Kill UHF Tag KI" on page 43
Filter Commands
Abbreviation Command description
FI
See "Set Filter Mask FI" on page 44
MF
See "Activate/Deactivate Filter MF" on page 45
Configuration Commands
Abbreviation Command description
6.4
RP
See "Read Parameters" on page 49
WP
See "Write Parameters" on page 49
Read/Write Commands
The tag's memory structure is based on the following read/write commands in accordance with
EPC Gen 2 (ISO/IEC 18000-63). See chapter 3.2.3.
Single Read Read-Only Code SF
One attempt is made to read a read-only code (TID). The read-only code is 4, 8, or 12 bytes
long, and comprises a 4-byte part number, which denotes the tag type, and optionally a tag
with a unique serial number of 4 or 8 bytes. Details see chapter 3.2.3.
Command:
SF
Response:
F 0001
= Length of the in ASCIIhex
Example:
SF1 reads the read-only code to IDENTControl channel 1.
Enhanced Read Read-Only Code EF
This command continuously attempts to read a read-only code (TID). If a read-only code is
read, this is reported once. If there is no tag in the detection range, or if the tag leaves the
detection range, a status 5 message is reported.
Command:
EF
Response:
= Length of the in ASCIIhex
Example:
2017-12
EF1 continuously reads the read-only code to IDENTControl Channel 1
39
IUH-F190-V1-*, IUT-F190-R4-V1*
Operation
Single Read Special Read-Only Code SS
This command reads the UII segment from tags according to EPC Gen2 (ISO/IEC 18000-63).
Command:
SS 0
Response:
F 0001
Example:
SS10 reads the entire UII segment.
The tag type determines the maximum length of the UII/EPC. The actual length of the UII/EPC
is defined via the protocol control word . The data is structured as follows:
= Length of the in ASCII hex
= &
corresponds to the protocol control word in accordance with EPC Gen 2 (ISO/IEC
18000-63), 2 bytes long.
contains the usage data.
Note!
UII/EPC
If there are multiple tags in the measurement range with the same UII/EPC, the identical tags
are reported with Status A.
Enhanced Read Special Read-Only Code ES
This command continuously attempts to read the UII segment from tags according to EPC Gen
2 (ISO/IEC 18000-63). If the of a tag is read, this is reported once. If there is
no tag in the detection range, or if the tag leaves the measurement range, a status 5 is reported.
Command:
ES 0
Response:
Example:
ES10 continuously reads the UII segment.
The tag type determines the maximum length of the UII/EPC. The actual length of the UII/EPC
is defined via the protocol control word . The data is structured as follows:
= Length of the in ASCII hex
= &
corresponds to the protocol control word in accordance with EPC Gen 2 (ISO/IEC
18000-63), 2 bytes long.
contains the usage data.
Note!
UII/EPC
2017-12
If there are multiple tags in the measurement range with the same UII/EPC, the identical tags
are reported with Status A.
40
IUH-F190-V1-*, IUT-F190-R4-V1*
Operation
Single Write Special Read-Only Code SP
This command writes a octet long UII/EPC code to tags according to EPC Gen 2
(ISO/IEC 18000-63).
Command: SP
Response: F
0001
The data length must be a whole number multiple of 2 octets because in accordance
with EPC Gen 2 (ISO/IEC 18000-63), must be written in 16-bit words. Only the
lengths 2 dec, 4dec , ... 14 dec (= 2 ASCII , 4ASCII , ..., EASCII) are permissible. The length is shown in
hexadecimal format, and includes the length of PC and UII/EPC. If a UII/EPC of 96 bits is
written, this results in 2 + 12 = 14 octets = E ASCII octet.
= Length of the in ASCIIhex
= &
corresponds to the protocol control word in accordance with EPC Gen 2 (ISO/IEC
18000-63), 2 octets long.
contains the usage data.
Example:
SP1E.30.00.30.14.F7.33.7C.00.1F.00.00.03.1C.6E writes the value ".30.00" for , and the
UII/EPC code ".30.14.F7.33.7C.00.1F.00.00.03.1C.6E" with a length of 2 + 12 octets = 14
octets to IDENTControl channel 1.
When using this command, make sure that the protocol control word contains the correct
length of the following UII/EPC. If this is not executed correctly, the complete data is not output
on the subsequent read operation because the command SS uses the length in the protocol
control word for the output.
In accordance with EPC Gen 2 (ISO/IEC 18000-63), the protocol control word consists of two
octets. The five highest value bits denote the length of the in words (= 16 bit):
00000 bin
No word
0 bits
00001 bin
One word
16 bits
00010 bin
Two words
32 bits
...
...
...
11111 bin
31 words
496 bits
The meaning of the remaining bits is described in EPC Gen 2 (ISO/IEC 18000-63). If a UII/EPC
has the length 12 octets, i.e., 6 words (00110 bin), and all other bits are equal to 0, the protocol
control word corresponds to 00110000 00000000 bin or 3000hex . If some of the other bits are
not equal to 0, this produces a different protocol control word.
Note!
Several Tags in the Measurement Range
2017-12
If there is more than one tag in the measurement range when this command is run, the UII is
written to the first tag only. Status A is output for all other tags.
41
IUH-F190-V1-*, IUT-F190-R4-V1*
Operation
Single Read Words SR
One attempt is made to read 32-bit words from address .
Command:
SR
Response:
F 0001
Example:
SR1000101 reads a 4-byte word from memory address "0001."
Note!
The memory bank (MB) parameter defines the bank accessed by this command. see
"Memory Module for Tag Accesses to the "Memory Bank" MB" on page 52.
Enhanced Read Words ER
Continuous attempts are made to read 32-bit words from the address
. Only changing data is transferred via the interface. When a read/write tag leaves
the read range, status 5 is output.
Command:
ER
Response:
Example:
ER1000101 continuously reads a 4-byte word from memory address "0001".
Note!
The memory bank (MB) parameter defines the bank accessed by this command. see
"Memory Module for Tag Accesses to the "Memory Bank" MB" on page 52.
Single Write Words SW
One attempt is made to write 32-bit words from the address .
Command:
SW
Response:
F 0001
Example:
SW1000101ABCD writes the 4-byte-long word "ABCD" from memory address "0001".
Note!
2017-12
The memory bank (MB) parameter defines the bank accessed by this command. see
"Memory Module for Tag Accesses to the "Memory Bank" MB" on page 52.
42
IUH-F190-V1-*, IUT-F190-R4-V1*
Operation
Note!
When writing to the UII/EPC area (MB = 1), note that it is not possible to write to the CRC. The
first writable address is 0x0001. The protocol control word begins at this address. Use
the command #SW.
Enhanced Write Words EW
This command continuously attempts to write 32-bit words from the address
. If the command was executed successfully, a status 0 is reported. If there is no
tag in the detection range, or if the tag leaves the detection range, a status 5 is reported.
Command:
EW
Response:
Example:
EW1000101ABCD continuously writes the 4-byte long word "ABCD" from memory address
"0001".
Note!
The memory bank (MB) parameter defines the bank accessed by this command. see
"Memory Module for Tag Accesses to the "Memory Bank" MB" on page 52.
Note!
16-Bit Read/Write Commands
The read/write commands SR, ER, SW, and EW are interpreted as 16-bit versions by means of
a preceding # symbol.
The 16-bit read/write commands behave in the same way as the 32-bit versions.
■ 16-bit commands write or read a word with a length of 2 bytes.
■
32-bit commands write or read a word with a length of 4 bytes.
Example:
#SW1000202ABCD corresponds to SW1000101ABCD
Kill UHF Tag KI
This command sets a UHF tag to a state where no further access is possible. The command
can be executed only if a valid password has previously been set in segment Bank 00 via the
command SW. See chapter 3.2.3. The password must have at least 1 non-zero bit.
Command:
KI .30.30 < UIIData>
Response:
F 0001
= Mask length for the UII/EPC in bits, values: 00 ... FF, always begins at Address 0.
The information is entered as 2 hexASCII characters.
= Specification of the mask for the UII, in octets
2017-12
= Password for killing a UHF tag, 4 octets
= Recommission bits, always set to zero
43
IUH-F190-V1-*, IUT-F190-R4-V1*
Operation
Example:
KI10018.E2.00.90abcd.00 kills a UHF tag with a UII starting ".E2.00.90" and using the
password "abcd."
6.5
Filter Commands
Each read or write command can access one, several, or all tags in a measurement range. The
process is controlled by filter masks, which are managed via the commands Set Filter Mask
(FI) and Activate/Deactivate Filter (MF). These commands allow you to detect specific tags in
the measurement range. see chapter 6.5.
Set Filter Mask FI
Using command FI, you can define a filter mask for accessing the tags located in the box. You
can define up to 3 filters (0-2). The following syntax is used:
Command:
FI
0
Response:
= Memory segment to which the filter is to be applied. The information is entered
as one hex ASCII character.
= Address of the bit at which the filter mask begins. Specified in hexASCII .
Values: 0000
FFFF
= Length of the mask in bits. The information is entered as 2 hex ASCII
characters.
= Defines the actual filter mask
Example:
There are three tags in the measurement range of the read/write head. Each tag has a unique
identifier of & :
&
1. Tag
.34.00.E2.00.92.01.20.51.70.00.00.00.02.76
2. Tag
.34.00.E2.00.92.01.20.51.70.00.00.00.02.66
3. Tag
.34.00.E2.00.90.51.33.02.00.92.18.20.56.15
If you want to detect the 3rd tag, the filter mask is: FI101000001028.34.00.E2.00.90
Meaning of Bits
FI
Command
Channel 1
First filter used, filter number = 0
Memory bank 01; should be filtered to
UII/EPC
Not negated
OR link
not relevant here because only one filter is set
Value is always 0
0010
Start address 10hex or bit 16
2017-12
Command
44
IUH-F190-V1-*, IUT-F190-R4-V1*
Operation
28
Mask length, 28hex = 40 dec , i.e., 40 bits
34.00.E2.00.90
Actual Mask
Owing to the structure of the memory bank for UII/EPC (
see image on page 12), the start
address is located at bit 16. The CRC-16 value occupies the memory position from bit 0
through bit 15; the PC starts at bit 16.
If you activate the filter with the command MF, and then execute command SS10, you receive
only one response from the corresponding tag even if other tags are located in the
measurement range:
.34.00.E2.00.90.51.33.02.00.92.18.20.56.15
The value controls the mask comparison. 0 = not negated, 1 = negated. If you
negate the filtering by setting the value in the command
FI101100001028.34.00.E2.00.90, you receive a response from the tags that does not match
the filter:
.34.00.E2.00.92.01.20.51.70.00.00.00.02.76
.34.00.E2.00.92.01.20.51.70.00.00.00.02.66
If you prefer to filter only at the start of , and ignore the , send the command
FI101000002018.E2.00.90. The start address is 20hex, the mask length has 24 bits, and the
mask is .E2.00.90.
The value logically links several filters with each other and is evaluated
only if more than one filter is used. If only one filter is used, this value is ignored. 0 = OR, 1 =
AND
Other examples include:
FI102000000018.E2.00.10 sets filter 0 so that all tags with a TID beginning with .E2.00.10 are
detected.
FI111100002008.22 sets filter 1 so that all tags whose UII/EPC do not begin .22 are detected.
FI1010100010700.00123456789012 sets filter 0 so that the tag with the SpecialFixcode
(PC+UII/EPC) 0.00123456789012 is detected.
The letter x can be used as a wildcard for the channel and filter number. Command
FIxx0000000000 resets the three filters for all IDENTControl channels.
Activate/Deactivate Filter MF
Command MF activates or deactivates the filter masks.
Command:
MF
Response:
The following values are possible:
0 = Deactivate filter masks
1 = Activate filter masks - mode 1
2 = Activate filter masks - mode 2
Example:
2017-12
MF11 activates the filter masks for IDENTControl channel 1
45
IUH-F190-V1-*, IUT-F190-R4-V1*
Operation
Command MF - Mode 1
In total, there are 15 tags in the measurement range of the read/write head, with three groups of
five marked as either A, B, or C. The filter is now set to "B" by the command FI.
If you execute command MF11 (Activate Filter - Mode 1), this command affects all subsequent
commands.
If a write command is executed next, all "B" tags in the measurement range are selected and
are assigned a 'Selected' flag. The write command is executed only for tags with a Selected
flag.
When the filter is set to "B", command MF11 (Filter Activated - Mode 1) selects all "B" tags; the
following commands address the selected "B" tags.
1 Read/write head
2 Tags "A", "B", "C"
3 Filter mask
4 Selected flag
Command MF - Mode 2
In total, there are 15 tags in the measurement range of the read/write head, with three groups of
five marked as either A, B, or C. The filter is set to "B" by command FI.
If you execute command MF12 (Activate Filter - Mode 2), this command affects all subsequent
commands.
2017-12
If a write command is executed next, all tags in the measurement range that are not "B" tags are
selected. These tags are assigned a 'Selected' flag. The write command is executed only for
tags with no Selected flag.
46
IUH-F190-V1-*, IUT-F190-R4-V1*
Operation
When the filter is set to "B," command MF12 (Filter Activated - Mode 2) selects all "A" and "C"
tags, and the following commands address the unselected "B" tags.
1 Read/write head
2 Tags "A", "B", "C"
3 Filter mask inverted
4 Selected flag
Difference Between Command MF - Mode 1 and Command MF - Mode 2
In both cases, the subsequent commands are applied only to the "B" tags in the measurement
range.
With MF11, "B" tags are assigned a Selected flag. With MF12, "B" tags are not assigned a
Selected flag.
If a "D" tag with a Selected flag from the operation of a different read/write head enters the
measurement range, this "D" tag will execute the subsequent commands if MF11 is activated. If
MF12 is activated, this "D" tag will not execute the subsequent commands.
6.6
Configuration Commands
2017-12
The response to a configuration command is a status message from the read/write head.
During the read operation, a status message and the corresponding data are received as the
response.
47
IUH-F190-V1-*, IUT-F190-R4-V1*
Operation
6.6.1
Read and Write Parameters
With the read parameter (RP) and write parameter (WP) configuration commands, you can
read/write the following parameters:
Abbreviation
Page
Parameter is readable/writeable
AP
See "Antenna Polarization AP" on
page 49
Readable/writeable
CD
See "CD Transmission Channels" on
page 50
Readable/writeable for RC = 1, 4, 5, 6,
Readable for RC = 2, 3, 7, 9, 10, 11,
12, 13, 14
E5
See "Number of Unsuccessful
Attempts until Status 5 "Enhanced
Status 5" E5" on page 50
Readable/writeable
FL
See "Read Out Filter Mask "Filter List" Readable
FL" on page 51
IF
See "Output Additional Information,
"Information" IF" on page 51
MB
See "Memory Module for Tag
Readable/writeable
Accesses to the "Memory Bank" MB"
on page 52
MD
See "Retrieve Additional Information
MD" on page 52
Readable
MF
See "Measurement of Reflected
Transmitting Power "Measure
Reflection" MF" on page 52
Readable
NC
See "Number of Channels NC" on
page 53
Readable/writeable for RC = 2, 3, 7, 9,
10, 11, 12, 13, 14
Readable for RC = 1, 4, 5, 6, 8
NT
See "Search Algorithm Cancellation
Criteria "number of tags to find" NT"
on page 53
Readable/writeable
PT
See "Transmission Power "Power
Transmit" PT" on page 54
Readable/writeable
QV
See "Protocol Mode QV" on page 55
Readable/writeable
QW
See "Q Value QW" on page 57
Readable/writeable
RC
See "Country Identifier, "Region
Code"" on page 57
Readable
RD
See "Reset to Default, RD" on page 58 Writeable
SM
See "Transmission Pauses in
"Sensing Mode" SM" on page 59
Readable/writeable
TA
See "Number of Attempts "Tries
Allowed" TA" on page 59
Readable/writeable
Readable/writeable
2017-12
The parameters are saved in the read/write head as nonvolatile.
48
IUH-F190-V1-*, IUT-F190-R4-V1*
Operation
Read Parameters
The RP command reads configuration parameters from the read/write head.
Command:
RP