switch on and off or carries out inclusion, exclusion, reset or association.
PAD02
When first power applied, its LED flashes on and off alternately and repeatedly at 0.5
second intervals. It implies that it has not been assigned a node ID and start auto
Z-Wave Smart Dimmer Socket
inclusion.
Auto Inclusion
The function of auto inclusion will be executed as long as the dimmer does not
have Node ID and just connect the switch to main power.
Note: Auto inclusion timeout is 2 minute during which the node information of
explorer frame will be emitted once every several seconds. Unlike “inclusion” function
as shown in the table below, the execution of auto inclusion is free from pressing the
On/Off button on the dimmer.
The table below lists an operation summary of basic Z-Wave functions. Please refer
Warning: Do not use Non-Dimmable LED lamps.
to the instructions for your Z-Wave Certificated Primary Controller to access the
TM
Setup function, and to include/exclude/associate devices
PAD02 is an E27(EU)/ E26(US) Edison screw based lamp socket, which provides
electrical connection to the E14(EU)/ E12(US) Edison screw based lamps and
Function
support it in the lighting fixture. The use of socket allows lamps to be safely and
No node ID
conveniently replaced. You can On/Off the light by pressing the button briefly,
or a long pressing to control the brightness of dimmable light bulb.
Inclusion
This dimmer is a transceiver which is a security enabled device which based on
Description
The Z-Wave Controller does not allocate
LED 2-second on, 2-second
a node ID to the Switch.
off
1.
One press one flash LED
Put your Z-Wave controller into
Z-Wave Plus technology, and it is fully compatible with any Z-Wave enabled
inclusion mode by following the
network. Since PAD02 supports Security Command Class, it can learn with
instructions provided by the
Secured controller. Its functionality and supported command classes is identical
controller manufacturer.
TM
2. Pressing Include button of PAD02
when included as a secure and non-secure device.
three times within 2 seconds will
enter inclusion mode.
Adding to Z-WaveTM Network
In the front casing, there is an on/off button with LED indicator below which is used to
Annotation
Exclusion
1.
Put your Z-Wave controller into
One press one flash LED
2. There are only one group for the
exclusion mode by following the
switch
instructions provided by the
Including a node ID allocated by Z-Wave Controller means inclusion.
controller manufacturer.
ID allocated by Z-Wave Controller means exclusion.
2. Pressing Include button of PAD02
Failed or success in including/excluding the node ID can be viewed from the Z-Wave
three times within 2 seconds will enter
Controller.
exclusion mode.
3. Node ID has been excluded.
Reset
0.5s On, 0.5s Off (Enter
auto inclusion)
LED Indication
1. Pressing Include button of PAD02
Use this procedure only in
To distinguish what mode the switch is in, view from the LED for identification.
three times within 2 seconds will
the event that the primary
enter inclusion mode.
controller is lost or
State Type
LED Indication
otherwise inoperable.
Normal
Whenever we switch On and off of the PAD02 by On/Off button or
2. Within 1 second, press Include button
RF command, the LED will lights up when switch on; whereas LED
of PAD02 again for 5 seconds.
3. IDs are excluded.
off when switch off.
0.5s On, 0.5s Off (Enter
No node ID
auto inclusion)
Association
Excluding a node
1.
Under normal operation, when the Switch has not been allocated a
The PAD02 is an always listening
node ID, the LED flashes on and off alternately at 2-second intervals.
Z-Wave device, so associations
By pressing On/Off button, it will stop flashing temporarily.
Learning
may be added or removed by a con-
When PAD02 is in learning mode, LED flashes on and off alternately
and repeatedly at 0.5 second intervals.
troller at any time.
Or If your controller requires to have
the PAD02 send a 'node information
Choosing a Suitable Location
frame' or NIF for associations, then
pressing the On/Off button three
times within 2 seconds will cause
1. Do not locate the dimmer facing direct sunlight, humid or dusty place.
the PAD02 to send its NIF.
2. The suitable ambient temperature for the Switch is 0°C~40°C.
3. Do not locate the dimmer where exists combustible substances or any source of
US TYPE: PAD02-2
heat, e.g. fires, radiators, boiler etc.
4. After putting it into use, the body of dimmer will become a little bit hot of which
phenomenon is normal.
screw lamp holder Type:
Since the socket type for each country in Europe varies, refer to the outline for each
socket suited for each country as follows:
EU TYPE: PAD02-1
Note: Please make sure that the intensity of the screw lampholder of the electrical
device must be Maximum Load (Watts) and have same head as the enclosed screw
lampholder before inserting to the socket.
Troubleshooting
Operating Temperature
0°C ~ 40°C
Frequency Range
868.40MHz & 869.85MHz/ EU (PAD02-1);
908.4MHz & 916.0MHz/ USA (PAD02-2);
Symptom
Cause of Failure
Recommendation
RF Maximum Power
+5dBm
The Switch not working 4. The Switch is not
1. Check power connections
Transmission Range
Minimum 40 m in door 100m outdoor line of sight
and LED off
2. Don’t open up the Switch and send it
Modulation Type
FSK (Frequency-Shift Keying)
plugged into the
electrical outlet properly
for repair.
** Specifications are subject to change and improvement without notice.
5. The Switch break down
The Switch LED
1.Check if the load
illuminating, but cannot
plugged into the Switch
control the ON/OFF
has its own ON/OFF
Switch of the load
switch
attached
2. The switch is protected
The Switch LED
1. Not carry out
illuminating, but the
association
FCC ID : RHHPAD02
1. Set the ON/OFF switch of the load
attached to ON
2. Unprotected the switch or follow the
instruction of protection.
1. Carry out association
2. Wait for a while to re-try
Warning: Do not use Non-Dimmable LED lamps.
Detector cannot control 2. Same frequency
the Switch
interference
Warning:
Specification
1.Plug out to disconnect from power supply; Do not plug in line.
2. Do not exceed the max rating.
Operating Voltage
100V~240V / 50Hz~60Hz
Maximum Load (watts)
40W (Incandescent bulbs); ( PAD02-1; PAD02-2)
Maximum Load (watts)
13W (Dimmable LED bulbs); ( PAD02-1; PAD02-2)
3. Do not use Non-Dimmable LED lamps.
Screw lamp holder Type: EU type: E27 to E14; PAD02-1
US type: E26 to E12; PAD02-2
• Connect the equipment into an outlet on a circuit different from that to which the receiver is
Disposal
This marking indicates that this product should not be disposed with
connected.
other household wastes throughout the EU. To prevent possible harm to
• Consult the dealer or an experienced radio/TV technician for help.
the environment or human health from uncontrolled waste disposal,
This device complies with Part 15 of the FCC Rules. Operation is subject
recycle it responsibly to promote the sustainable reuse of material
to the following two conditions:
resources. To return your used device, please use the return and
(1) This device may not cause harmful interference, and
collection systems or contact the retailer where the product was
(2) This device must accept any interference received, including interference that may cause
purchased. They can take this product for environmental safe recycling.
undesired operation.
Company of License Holder:Philio Technology Corporation
FCC Caution: Any changes or modifications not expressly approved by the party responsible
Address of License Holder:8F., No.653-2, Zhongzheng Rd., Xinzhuang Dist., New Taipei City
for compliance could void the user's authority to operate this equipment.
24257, Taiwan(R.O.C)
This transmitter must not be co-located or operating in conjunction with any other antenna or
transmitter.
FCC Interference Statement
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules.
These limits are designed to provide reasonable protection against harmful interference in a
residential installation.
This equipment generates, uses and can radiate radio frequency energy and, if not installed
and used in accordance with the instructions, may cause harmful interference to
radio communications.
However, there is no guarantee that interference will not occur in a particular installation.
If this equipment does cause harmful interference to radio or television reception, which
can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one of the following measures:
• Reorient or relocate the receiving antenna.
• Increase the separation between the equipment and receiver.

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.4
Linearized                      : No
Page Count                      : 5
Language                        : zh-TW
Creator                         : Writer
Producer                        : LibreOffice 5.0
Create Date                     : 2016:11:04 15:43:39+08:00
EXIF Metadata provided by EXIF.tools
FCC ID Filing: RHHPAD02

Navigation menu