Philio Technology PAD02 Smart Dimmer Socket User Manual
Philio Technology Corporation Smart Dimmer Socket
User manual
switch on and off or carries out inclusion, exclusion, reset or association. PAD02 When first power applied, its LED flashes on and off alternately and repeatedly at 0.5 second intervals. It implies that it has not been assigned a node ID and start auto Z-Wave Smart Dimmer Socket inclusion. Auto Inclusion The function of auto inclusion will be executed as long as the dimmer does not have Node ID and just connect the switch to main power. Note: Auto inclusion timeout is 2 minute during which the node information of explorer frame will be emitted once every several seconds. Unlike “inclusion” function as shown in the table below, the execution of auto inclusion is free from pressing the On/Off button on the dimmer. The table below lists an operation summary of basic Z-Wave functions. Please refer Warning: Do not use Non-Dimmable LED lamps. to the instructions for your Z-Wave Certificated Primary Controller to access the TM Setup function, and to include/exclude/associate devices PAD02 is an E27(EU)/ E26(US) Edison screw based lamp socket, which provides electrical connection to the E14(EU)/ E12(US) Edison screw based lamps and Function support it in the lighting fixture. The use of socket allows lamps to be safely and No node ID conveniently replaced. You can On/Off the light by pressing the button briefly, or a long pressing to control the brightness of dimmable light bulb. Inclusion This dimmer is a transceiver which is a security enabled device which based on Description The Z-Wave Controller does not allocate LED 2-second on, 2-second a node ID to the Switch. off 1. One press one flash LED Put your Z-Wave controller into Z-Wave Plus technology, and it is fully compatible with any Z-Wave enabled inclusion mode by following the network. Since PAD02 supports Security Command Class, it can learn with instructions provided by the Secured controller. Its functionality and supported command classes is identical controller manufacturer. TM 2. Pressing Include button of PAD02 when included as a secure and non-secure device. three times within 2 seconds will enter inclusion mode. Adding to Z-WaveTM Network In the front casing, there is an on/off button with LED indicator below which is used to Annotation Exclusion 1. Put your Z-Wave controller into One press one flash LED 2. There are only one group for the exclusion mode by following the switch instructions provided by the Including a node ID allocated by Z-Wave Controller means inclusion. controller manufacturer. ID allocated by Z-Wave Controller means exclusion. 2. Pressing Include button of PAD02 Failed or success in including/excluding the node ID can be viewed from the Z-Wave three times within 2 seconds will enter Controller. exclusion mode. 3. Node ID has been excluded. Reset 0.5s On, 0.5s Off (Enter auto inclusion) LED Indication 1. Pressing Include button of PAD02 Use this procedure only in To distinguish what mode the switch is in, view from the LED for identification. three times within 2 seconds will the event that the primary enter inclusion mode. controller is lost or State Type LED Indication otherwise inoperable. Normal Whenever we switch On and off of the PAD02 by On/Off button or 2. Within 1 second, press Include button RF command, the LED will lights up when switch on; whereas LED of PAD02 again for 5 seconds. 3. IDs are excluded. off when switch off. 0.5s On, 0.5s Off (Enter No node ID auto inclusion) Association Excluding a node 1. Under normal operation, when the Switch has not been allocated a The PAD02 is an always listening node ID, the LED flashes on and off alternately at 2-second intervals. Z-Wave device, so associations By pressing On/Off button, it will stop flashing temporarily. Learning may be added or removed by a con- When PAD02 is in learning mode, LED flashes on and off alternately and repeatedly at 0.5 second intervals. troller at any time. Or If your controller requires to have the PAD02 send a 'node information Choosing a Suitable Location frame' or NIF for associations, then pressing the On/Off button three times within 2 seconds will cause 1. Do not locate the dimmer facing direct sunlight, humid or dusty place. the PAD02 to send its NIF. 2. The suitable ambient temperature for the Switch is 0°C~40°C. 3. Do not locate the dimmer where exists combustible substances or any source of US TYPE: PAD02-2 heat, e.g. fires, radiators, boiler etc. 4. After putting it into use, the body of dimmer will become a little bit hot of which phenomenon is normal. screw lamp holder Type: Since the socket type for each country in Europe varies, refer to the outline for each socket suited for each country as follows: EU TYPE: PAD02-1 Note: Please make sure that the intensity of the screw lampholder of the electrical device must be Maximum Load (Watts) and have same head as the enclosed screw lampholder before inserting to the socket. Troubleshooting Operating Temperature 0°C ~ 40°C Frequency Range 868.40MHz & 869.85MHz/ EU (PAD02-1); 908.4MHz & 916.0MHz/ USA (PAD02-2); Symptom Cause of Failure Recommendation RF Maximum Power +5dBm The Switch not working 4. The Switch is not 1. Check power connections Transmission Range Minimum 40 m in door 100m outdoor line of sight and LED off 2. Don’t open up the Switch and send it Modulation Type FSK (Frequency-Shift Keying) plugged into the electrical outlet properly for repair. ** Specifications are subject to change and improvement without notice. 5. The Switch break down The Switch LED 1.Check if the load illuminating, but cannot plugged into the Switch control the ON/OFF has its own ON/OFF Switch of the load switch attached 2. The switch is protected The Switch LED 1. Not carry out illuminating, but the association FCC ID : RHHPAD02 1. Set the ON/OFF switch of the load attached to ON 2. Unprotected the switch or follow the instruction of protection. 1. Carry out association 2. Wait for a while to re-try Warning: Do not use Non-Dimmable LED lamps. Detector cannot control 2. Same frequency the Switch interference Warning: Specification 1.Plug out to disconnect from power supply; Do not plug in line. 2. Do not exceed the max rating. Operating Voltage 100V~240V / 50Hz~60Hz Maximum Load (watts) 40W (Incandescent bulbs); ( PAD02-1; PAD02-2) Maximum Load (watts) 13W (Dimmable LED bulbs); ( PAD02-1; PAD02-2) 3. Do not use Non-Dimmable LED lamps. Screw lamp holder Type: EU type: E27 to E14; PAD02-1 US type: E26 to E12; PAD02-2 • Connect the equipment into an outlet on a circuit different from that to which the receiver is Disposal This marking indicates that this product should not be disposed with connected. other household wastes throughout the EU. To prevent possible harm to • Consult the dealer or an experienced radio/TV technician for help. the environment or human health from uncontrolled waste disposal, This device complies with Part 15 of the FCC Rules. Operation is subject recycle it responsibly to promote the sustainable reuse of material to the following two conditions: resources. To return your used device, please use the return and (1) This device may not cause harmful interference, and collection systems or contact the retailer where the product was (2) This device must accept any interference received, including interference that may cause purchased. They can take this product for environmental safe recycling. undesired operation. Company of License Holder:Philio Technology Corporation FCC Caution: Any changes or modifications not expressly approved by the party responsible Address of License Holder:8F., No.653-2, Zhongzheng Rd., Xinzhuang Dist., New Taipei City for compliance could void the user's authority to operate this equipment. 24257, Taiwan(R.O.C) This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter. FCC Interference Statement This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one of the following measures: • Reorient or relocate the receiving antenna. • Increase the separation between the equipment and receiver.
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.4 Linearized : No Page Count : 5 Language : zh-TW Creator : Writer Producer : LibreOffice 5.0 Create Date : 2016:11:04 15:43:39+08:00EXIF Metadata provided by EXIF.tools