Philio Technology PAD07 In Wall Smart Dimmer User Manual

Philio Technology Corporation In Wall Smart Dimmer

User manual

PAD07   In Wall Smart Dimmer                                              Warning: Do not use Non-Dimmable LED lamps.                            Fig 1. Assembling & WiringBuilt-in High Breaking Capacity current fuse protection. Rating : 2A /250V.Built-in Thermal Cutoff Fuses protection. Rated Temperature :125 °C; Rating : 2A /250V.PAD07 is a security enabled wireless dimmer, based on Z-Wave Plus technology. Z-Wave PlusTM enabled devices displaying the Z-Wave PlusTM logo can also be used with it regardless of the manufacturer, and can also be used in other manufacturer’s Z-WaveTM enabled networks. You can On/Off the light by pressing the button briefly, or a long pressing to control the brightness of dimmable light bulb.This dimmer is a transceiver which is a security enabled device which based on Z-Wave Plus technology, and it is fully compatible with any Z-WaveTM enabled network. Since PAD07 supports Security Command Class, it can learn with Secured controller. Its functionality and supported command classes is identical when included as a secure and non-secure device.Adding to Z-WaveTM NetworkIn the front casing, there is an on/off button (also an include button) with LED indica-tor below which is used to dim on and off or carries out inclusion, exclusion, reset or association. When first power applied, its LED flashes on and off alternately and re-peatedly at 0.5 second intervals. It implies that it has not been assigned a node ID and start auto inclusion.Auto InclusionThe function of auto inclusion will be executed as long as the dimmer does nothave Node ID and just connect the switch to main power.Note: Auto inclusion timeout is 2 minute during which the node information ofexplorer frame will be emitted once every several seconds. Unlike “inclusion” functionas shown in the table below, the execution of auto inclusion is free from pressing the1
On/Off button on the dimmer.The table below lists an operation summary of basic Z-Wave functions. Please referto the instructions for your Z-WaveTM Certificated Primary Controller to access theSetup function, and to Add/Remove/associate devicesFunction Description AnnotationNo node ID The Z-Wave Controller does not allocatea node ID to the Switch.LED 2-second on, 2-second offAdd (Inclusion) 1. Put your Z-Wave controller intoinclusion mode by following theinstructions provided by thecontroller manufacturer.2.  Pressing Include button of PAD07 three times within 2 seconds will enter inclusion mode.Remove (Exclusion)1. Put your Z-Wave controller intoexclusion mode by following theinstructions provided by thecontroller manufacturer.2. Pressing Include button of PAD07three times within 2 seconds will enter exclusion mode.3. Node ID has been excluded. 0.5s On, 0.5s Off (Enterauto inclusion)Reset 1. Pressing Include button of PAD07 three times within 2 seconds will enter inclusion mode.Use this procedure only inthe event that the primarycontroller is lost orotherwise inoperable.2. Within 1 second, press Include buttonof PAD07 again for 5 seconds.3. IDs are excluded. 0.5s On, 0.5s Off (Enterauto inclusion)Association 1. The PAD07 is an always listeningZ-Wave device, so associations may be added or removed by a con-troller at any time.Or  If your controller requires to havethe PAD07 send a 'node informationframe' or NIF for associations, thenpressing the On/Off button threetimes within 2 seconds will causethe PAD07 to send its NIF.2.  There is only one group for the dimmerAdding a node ID allocated by Z-Wave Controller means inclusion. Removing a nodeID allocated by Z-Wave Controller means exclusion.Failed or success in including/excluding the node ID can be viewed from the Z-Wave Controller. LED Indication2
To distinguish what mode the switch is in, view from the LED for identification.State Type LED IndicationNormal Whenever we switch On and off of the PAD07 by On/Off button or RF command, the LED will lights up when switch on; whereas LED off when switch off.No node ID Under normal operation, when the Switch has not been allocated a node ID, the LED flashes on and off alternately at 2-second intervals. By pressing On/Off button, it will stop flashing temporarily.Learning When PAD07 is in learning mode, LED flashes on and off alternately and repeatedly at 0.5 second intervals.Choosing a Suitable Location1. Do not locate the dimmer facing direct sunlight, humid or dusty place.2. The suitable ambient temperature for the Switch is 0°C~40°C.3. Do not locate the dimmer where exists combustible substances or any source of heat, e.g. fires, radiators, boiler etc.4. After putting it into use, the body of dimmer will become a little bit hot of which phenomenon is normal.Manual dim level control :To manually switch on the light, press and release the On/Off button or S1/S2 shortly when the light is off. The light will dim from off to the level which was set before switch off. To manually switch off the light, press and release the On/Off button or S1/S2 shortly when the light is on. To adjust the dim level, press and hold the On/Off button or S1/S2 until the desired dim level is achieved, then release.Programming1. Basic Command Class / Multilevel Switch Command ClassThe dimmer will respond to BASIC and MULTILEVEL SWITCH commands that are part of the Z-Wave system. If PAD07 is included as a secured node, it will only re-sponse to the security encapsulation command of BASIC and MULTILEVEL SWITCH.1-1 BASIC_GET / MULTILEVEL_SWITCH_GETUpon receipt of the following commands from a Z-Wave Controller, the Switch willreport its dimmer state to the node inquired.Basic Get Command: [Command Class Basic, Basic Get]Basic Report Command:Report OFF: [Command Class Basic, Basic Report, Value = 0]Report ON:[Command Class Basic, Basic Report, Value = 1~99]Multilevel Switch Get Command:[Command Class Multilevel Switch, Multilevel Switch Get]Multilevel Switch Report Command:Report OFF:[Command Class Multilevel Switch, Multilevel Switch Report, Value=0]Report ON:[Command Class Multilevel Switch, Multilevel Switch Report, Value=1~99]3
1-2 BASIC_SET / MULTILEVEL_SWITCH _SETUpon receipt of the following commands from a Z-Wave Controller, the loadattached to the dimmer will turn on or off.[Command Class Basic, Basic Set, Value = 0] : the load attached to thedimmer turns off.[Command Class Basic, Basic Set, Value = 1~99] : the attached load dim on as the level.[Command Class Multilevel Switch, Multilevel Switch Set, Value=0, Duration = 0~255] : the load attached to the dimmer turns off.[Command Class Multilevel Switch, Multilevel Switch Set, Value =1~99, Dura-tion = 0~255] : the attached load dim on as the level.1. Z-Wave’s Groups (Maximum 5 nodes)The Switch can be set to send reports to associated Z-Wave devices. It supportsone association group with five nodes support for grouping 1. For group 1, the dim-merwill report MULTILEVEL_SWITCH_REPORT, ALARM_REPORT and DEVICE_RE-SET_LOCALLY_NOTIFICATION.2-1 Auto report to Grouping 12-1-1 On/Off Event ReportWhen “on” or “off ” state has been changed, it will send Multilevel Switch Report to thenodes of Grouping 1.Multilevel Switch ReportON:[Command Class Multilevel Switch, Multilevel Switch Report, Value=1~99]OFF:[Command Class Multilevel Switch, Multilevel Switch Report, Value =0(0x00)]2-1-2 Overload alarm reportWhen PAD07 detects the Overload, it will send Alarm Report to Group 1 nodes. After detecting overload state and sending this alarm report, PAD07 will turn off the dim-mer automatically and lockout the On/Off button and S1/S2. The only thing to do is unplug PAD07 and reduce the load. Then re-power on PAD07 and it will work again.The content of Alarm ReportAlarm report command: [Command_Class_Alarm, Alarm_Report, Alarm Type = 0x08, Alarm Level = 0xFF]2-2 Send Basic Set to Grouping 1When “on” or “off ” state has been changed by manual key pressing, a Basic Set command will follow the Multilevel Switch Report send to the nodes of Grouping 1.[Command Class Basic, Basic Set, Value = 0] [Command Class Basic, Basic Set, Value = 1~99] 3. Z-Wave’s ConfigurationConfigurationParameterFunction Size(Byte)Value Unit Default Description1 Dimmer LevelReport mode1 0-1 1 0 : Disable1 : Enable2 LED indication mode1 1-3 1 1: Show dimmer state2 : Show night mode3: One flash mode4
3 External switch type1 1-3 1 1 : One switch mode2 : Two switch mode3: Up/Down switch mode4 Restore dimmer state1 0-2 1 0 : Dimmer off1 : Last dimmer state2 : Dimmer on3-1 Dimmer level report mode :    Whenever dimmer on/off state changes, it will send MULTILEVEL_SWITCH_REPORT to the nodes of group1. The default setting is Enable the function.3-2 LED indication mode : 3-2-1 Show dimmer State:When dimmer is on, LED is on. When dimmer is off,LED is off. The default setting is Show dimmer State.  3-2-2 Show Night mode :When dimmer is on, LED is off. When  dimmer  is off,LED is on.3-2-3 One flash mode:When dimmer on/off state changes, LED will light on onesecond and then off.3-3 External switch type: 3-3-1 One switch mode:Only S1 can dim up the light bulb to brightest level, thendim down to darkest level, and so on… 3-3-2 Two switch mode:S1 and S2 can dim up the light bulb to brightest level,then dim down to darkest level, and so on…3-3-3 Up/Down switch mode:S1 can only dim up the light bulb to brightest level,and S2 can only dim down to Off.3-4 restore dimmer state : Whenever the AC power return from lost, PAD07 will restore the switch state whichcould be Dimmer off、Last dimmer state、Dimmer on. The default setting is Last dim-mer state.4. Firmware update over the air (OTA)PAD07 is based on 500 series SoC and supports Firmware Update Command Class, it can receives the updated firmware image sent by controller via the Z-wave RF media. It is a helpful and convenient way to improve some function if needed.5. Command ClassesThe Switch supports Command Classes including…* COMMAND_CLASS_ZWAVEPLUS_INFO* COMMAND_CLASS_VERSION_V2* COMMAND_CLASS_MANUFACTURER_SPECIFIC_V2* COMMAND_CLASS_SECURITY* COMMAND_CLASS_DEVICE_RESET_LOCALLY* COMMAND_CLASS_ASSOCIATION_V2* COMMAND_CLASS_ASSOCIATION_GRP_INFO* COMMAND_CLASS_POWERLEVEL* COMMAND_CLASS_BASIC* COMMAND_CLASS_SWITCH_MULTILEVEL_V2* COMMAND_CLASS_CONFIGURATION * COMMAND_CLASS_ALARM* COMMAND_CLASS_FIRMWARE_UPDATE_MD_V2* COMMAND_CLASS_SCENE_ACTIVATION* COMMAND_CLASS_SCENE_ACTUATOR_CONF5
Troubleshooting                 Symptom Cause of Failure RecommendationThe dimmer does not work and LED off1.The dimmer does not connect the electrical wire properly2.The dimmer break down1. Check power connections2. Don’t open up the dimmer and send it for repair.The dimmer LED illuminating, but cannot control the ON/OFF state of the load attachedCheck if the load connected to the dimmer has its own ON/OFF switchSet the ON/OFF switch of the load attachedto ONThe dimmer LED illuminating, but the Detector cannot control the Switch1. Not carry out association2. Same frequency interference1. Carry out association2. Wait for a while to re-trySpecificationInput Rating:(Operating Voltage) 100~240Vac / 50Hz~60HzInput Rating:(Operating Current) 0.01~1A ; (Maximum: 1A)Output Rating: Maximum Load (Current) Maximum: 0.9A (100~240Vac)Output Rating: Maximum Load (watts)(230V)200W (13W x 15 pieces) (Dimmable LED bulbs)(230Vac) Output Rating: Maximum Load (watts)(120V)100W (13W x 15 pieces) (Dimmable LED bulbs)(120Vac) Output Rating: Maximum Dimmable LEDbulbs Maximum: 15 pieces (Dimmable LED bulbs)Operating Temperature 0°C ~ 40°CFrequency Range 868.40MHz & 869.85MHz/ EU (PAD07-EU); 908.4MHz & 916.0MHz/ USA (PAD07-US);RF Maximum Power +5dBm Transmission Range Minimum 40 m in door 100m outdoor line of sightModulation Type  FSK (Frequency-Shift Keying)** Specifications are subject to change and improvement without notice.                    FCC ID : RHHPAD076
Warning:  Do not use Non-Dimmable LED lamps.DANGER   Danger of electrocution!All works on the device may be performed only by a qualified and licensed electrician. Observe national regulations. Any works introducing changes into the configuration must be always performed with disconnected voltage. Choosing a Suitable Location1. Do not locate the Module facing direct sunlight, humid or dusty place.2. The suitable ambient temperature for the Module is 0°C~40°C.3. Do not locate the Module where exists combustible substances or any source of heat, e.g. fires, radiators, boiler etc.4. After putting it into use, the body of Module will become a little bit hot of whichphenomenon is normal.Warning:1.Plug out to disconnect from power supply; Do not plug in line. 2. Do not exceed the max rating.3. Do not use Non-Dimmable LED lamps.Disposal This marking indicates that this product should not be disposed with other household wastes throughout the EU. To prevent possible harm to the environment or human health from uncontrolled waste disposal, recycle it responsibly to promote the sustainable reuse of material resources. To return your used device, please use the return and collection systems or contact the retailer where the product was purchased. They can take this product for environmental safe recycling.Company of License Holder:Philio Technology CorporationAddress of License Holder:8F., No.653-2, Zhongzheng Rd., Xinzhuang Dist., New Taipei City24257, Taiwan(R.O.C) FCC Interference StatementThis equipment has been tested and found to comply with the limits for a Class B digital de-vice, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference toradio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, whichcan be determined by turning the equipment off and on, the user is encouraged to try to cor-rect the interference by one of the following measures:• Reorient or relocate the receiving antenna.• Increase the separation between the equipment and receiver.7
• Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.• Consult the dealer or an experienced radio/TV technician for help.This device complies with Part 15 of the FCC Rules. Operation is subjectto the following two conditions:(1) This device may not cause harmful interference, and(2) This device must accept any interference received, including interference that may cause undesired operation.FCC Caution: Any changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate this equipment.This transmitter must not be co-located or operating in conjunction with any other antenna ortransmitter.8