Philio Technology PAD07 In Wall Smart Dimmer User Manual
Philio Technology Corporation In Wall Smart Dimmer
User manual
Built-in High Breaking Capacity current fuse protection. Rating : 2A /250V. PAD07 In Wall Smart Dimmer Built-in Thermal Cutoff Fuses protection. Rated Temperature :125 °C; Rating : 2A /250V. PAD07 is a security enabled wireless dimmer, based on Z-Wave Plus technology. ZWave PlusTM enabled devices displaying the Z-Wave PlusTM logo can also be used with it regardless of the manufacturer, and can also be used in other manufacturer’s Z-WaveTM enabled networks. You can On/Off the light by pressing the button briefly, or a long pressing to control the brightness of dimmable light bulb. This dimmer is a transceiver which is a security enabled device which based on Warning: Do not use Non-Dimmable LED lamps. Z-Wave Plus technology, and it is fully compatible with any Z-WaveTM enabled network. Since PAD07 supports Security Command Class, it can learn with Secured controller. Its functionality and supported command classes is identical when included as a secure and non-secure device. Adding to Z-WaveTM Network In the front casing, there is an on/off button (also an include button) with LED indicator below which is used to dim on and off or carries out inclusion, exclusion, reset or association. When first power applied, its LED flashes on and off alternately and repeatedly at 0.5 second intervals. It implies that it has not been assigned a node ID and start auto inclusion. Auto Inclusion The function of auto inclusion will be executed as long as the dimmer does not have Node ID and just connect the switch to main power. Note: Auto inclusion timeout is 2 minute during which the node information of explorer frame will be emitted once every several seconds. Unlike “inclusion” function Fig 1. Assembling & Wiring as shown in the table below, the execution of auto inclusion is free from pressing the On/Off button on the dimmer. Reset 1. Pressing Include button of PAD07 Use this procedure only in The table below lists an operation summary of basic Z-Wave functions. Please refer three times within 2 seconds will the event that the primary to the instructions for your Z-WaveTM Certificated Primary Controller to access the enter inclusion mode. controller is lost or Setup function, and to Add/Remove/associate devices 2. Within 1 second, press Include button otherwise inoperable. of PAD07 again for 5 seconds. Function No node ID Add (Inclusion) Description Annotation The Z-Wave Controller does not allocate LED 2-second on, 2-second a node ID to the Switch. off 1. 3. IDs are excluded. auto inclusion) Association 1. Z-Wave device, so associations inclusion mode by following the may be added or removed by a con- instructions provided by the troller at any time. Or If your controller requires to have 2. Pressing Include button of PAD07 1. (Exclusion) the PAD07 send a 'node information three times within 2 seconds will frame' or NIF for associations, then enter inclusion mode. pressing the On/Off button three Put your Z-Wave controller into times within 2 seconds will cause exclusion mode by following the the PAD07 to send its NIF. instructions provided by the 2. There is only one group for the controller manufacturer. 2. The PAD07 is an always listening Put your Z-Wave controller into controller manufacturer. Remove dimmer Adding a node ID allocated by Z-Wave Controller means inclusion. Removing a node Pressing Include button of PAD07 three times within 2 seconds will ID allocated by Z-Wave Controller means exclusion. Failed or success in including/excluding the node ID can be viewed from the Z-Wave enter exclusion mode. 3. Node ID has been excluded. 0.5s On, 0.5s Off (Enter 0.5s On, 0.5s Off (Enter Controller. auto inclusion) LED Indication To distinguish what mode the switch is in, view from the LED for identification. S1/S2 shortly when the light is on. To adjust the dim level, press and hold the On/Off button or S1/S2 until the desired dim level is achieved, then release. State Type LED Indication Normal Whenever we switch On and off of the PAD07 by On/Off button or RF No node ID Learning command, the LED will lights up when switch on; whereas LED off Programming when switch off. 1. Basic Command Class / Multilevel Switch Command Class Under normal operation, when the Switch has not been allocated a The dimmer will respond to BASIC and MULTILEVEL SWITCH commands that are node ID, the LED flashes on and off alternately at 2-second intervals. part of the Z-Wave system. If PAD07 is included as a secured node, it will only re- By pressing On/Off button, it will stop flashing temporarily. sponse to the security encapsulation command of BASIC and MULTILEVEL When PAD07 is in learning mode, LED flashes on and off alternately SWITCH. and repeatedly at 0.5 second intervals. 1-1 BASIC_GET / MULTILEVEL_SWITCH_GET Upon receipt of the following commands from a Z-Wave Controller, the Switch will report its dimmer state to the node inquired. Basic Get Command: [Command Class Basic, Basic Get] Choosing a Suitable Location Basic Report Command: 1. Do not locate the dimmer facing direct sunlight, humid or dusty place. Report OFF: [Command Class Basic, Basic Report, Value = 0] 2. The suitable ambient temperature for the Switch is 0°C~40°C. Report ON:[Command Class Basic, Basic Report, Value = 1~99] 3. Do not locate the dimmer where exists combustible substances or any source of Multilevel Switch Get Command:[Command Class Multilevel Switch, Multilevel heat, e.g. fires, radiators, boiler etc. Switch Get] 4. After putting it into use, the body of dimmer will become a little bit hot of which phenomenon is normal. Multilevel Switch Report Command: Report OFF:[Command Class Multilevel Switch, Multilevel Switch Report, Manual dim level control : Value=0] To manually switch on the light, press and release the On/Off button or S1/S2 shortly Report ON:[Command Class Multilevel Switch, Multilevel Switch Report, Value when the light is off. The light will dim from off to the level which was set before =1~99] switch off. To manually switch off the light, press and release the On/Off button or Switch Report 1-2 BASIC_SET / MULTILEVEL_SWITCH _SET Multilevel Upon receipt of the following commands from a Z-Wave Controller, the load ON:[Command Class Multilevel Switch, Multilevel Switch Report, Value attached to the dimmer will turn on or off. =1~99] OFF:[Command Class Multilevel Switch, Multilevel Switch Report, Value [Command Class Basic, Basic Set, Value = 0] : the load attached to the =0(0x00)] dimmer turns off. 2-1-2 Overload alarm report [Command Class Basic, Basic Set, Value = 1~99] : the attached load dim on as When PAD07 detects the Overload, it will send Alarm Report to Group 1 nodes. After the level. detecting overload state and sending this alarm report, PAD07 will turn off the dimmer automatically and lockout the On/Off button and S1/S2. The only thing to do is [Command Class Multilevel Switch, Multilevel Switch Set, Value=0, Duration = unplug PAD07 and reduce the load. Then re-power on PAD07 and it will work again. 0~255] : the load attached to the dimmer turns off. The content of Alarm Report [Command Class Multilevel Switch, Multilevel Switch Set, Value =1~99, Dura- Alarm report command: [Command_Class_Alarm, Alarm_Report, Alarm Type = tion = 0~255] : the attached load dim on as the level. 0x08, Alarm Level = 0xFF] 2-2 Send Basic Set to Grouping 1 1. Z-Wave’s Groups (Maximum 5 nodes) When “on” or “off ” state has been changed by manual key pressing, a Basic Set The Switch can be set to send reports to associated Z-Wave devices. It supports command will follow the Multilevel Switch Report send to the nodes of Grouping 1. one association group with five nodes support for grouping 1. For group 1, the dim- [Command Class Basic, Basic Set, Value = 0] mer [Command Class Basic, Basic Set, Value = 1~99] will report MULTILEVEL_SWITCH_REPORT, ALARM_REPORT and DEVICE_RE- 3. Z-Wave’s Configuration SET_LOCALLY_NOTIFICATION. Configuration 2-1 Auto report to Grouping 1 Parameter 2-1-1 On/Off Event Report Function Size Value Unit Default Description 0 : Disable (Byte) Dimmer Level 0-1 1 : Enable When “on” or “off ” state has been changed, it will send Multilevel Switch Report to Report mode the LED indication 1-3 1: Show dimmer state 2 : Show night mode nodes of Grouping 1. mode 3: One flash mode 3 External switch 1-3 could be Dimmer off、Last dimmer state、Dimmer on. The default setting is Last dim- 1 : One switch mode 2 : Two switch mode type mer state. 3: Up/Down switch mode Restore dimmer 0-2 0 : Dimmer off 4. Firmware update over the air (OTA) 1 : Last dimmer state state PAD07 is based on 500 series SoC and supports Firmware Update Command 2 : Dimmer on Class, it can receives the updated firmware image sent by controller via the Zwave RF media. It is a helpful and convenient way to improve some function if 3-1 Dimmer level report mode : needed. Whenever dimmer on/off state changes, it will send MULTILEVEL_SWITCH_ REPORT to the nodes of group1. The default setting is Enable the function. 5. Command Classes 3-2 LED indication mode : The Switch supports Command Classes including… 3-2-1 Show dimmer State:When dimmer is on, LED is on. When dimmer is off, * COMMAND_CLASS_ZWAVEPLUS_INFO LED is off. The default setting is Show dimmer State. * COMMAND_CLASS_VERSION_V2 3-2-2 Show Night mode : When dimmer is on, LED is off. When dimmer is off, * COMMAND_CLASS_MANUFACTURER_SPECIFIC_V2 LED is on. * COMMAND_CLASS_SECURITY 3-2-3 One flash mode:When dimmer on/off state changes, LED will light on one * COMMAND_CLASS_DEVICE_RESET_LOCALLY second and then off. * COMMAND_CLASS_ASSOCIATION_V2 * COMMAND_CLASS_ASSOCIATION_GRP_INFO 3-3 External switch type: * COMMAND_CLASS_POWERLEVEL 3-3-1 One switch mode:Only S1 can dim up the light bulb to brightest level, then * COMMAND_CLASS_BASIC dim down to darkest level, and so on… * COMMAND_CLASS_SWITCH_MULTILEVEL_V2 3-3-2 Two switch mode:S1 and S2 can dim up the light bulb to brightest level, * COMMAND_CLASS_CONFIGURATION then dim down to darkest level, and so on… * COMMAND_CLASS_ALARM 3-3-3 Up/Down switch mode:S1 can only dim up the light bulb to brightest level, * COMMAND_CLASS_FIRMWARE_UPDATE_MD_V2 and S2 can only dim down to Off. * COMMAND_CLASS_SCENE_ACTIVATION 3-4 restore dimmer state : * COMMAND_CLASS_SCENE_ACTUATOR_CONF Whenever the AC power return from lost, PAD07 will restore the switch state which Specification Troubleshooting Input Rating:(Operating Voltage) 100~240Vac / 50Hz~60Hz 0.01~1A ; (Maximum: 1A) Symptom Cause of Failure Recommendation Input Rating:(Operating Current) The dimmer does not 1.The dimmer does not 1. Check power connections Output Rating: Maximum Load (Current) Maximum: 0.9A (100~240Vac) 2. Don’t open up the dimmer and send it for Output Rating: Maximum Load (watts) 200W (13W x 15 pieces) (Dimmable LED bulbs) (230V) (230Vac) Output Rating: Maximum Load (watts) 100W (13W x 15 pieces) (Dimmable LED bulbs) (120V) (120Vac) work and LED off connect the electrical wire properly repair. 2.The dimmer break down The dimmer LED Check if the load Set the ON/OFF switch of the load attached illuminating, but cannot connected to the dimmer to ON Output Rating: Maximum Dimmable LED Maximum: 15 pieces (Dimmable LED bulbs) control the ON/OFF has its own ON/OFF bulbs state of the load switch Operating Temperature 0°C ~ 40°C Frequency Range 868.40MHz & 869.85MHz/ EU (PAD07-EU); attached The dimmer LED illuminating, but the 1. Not carry out association 1. Carry out association 908.4MHz & 916.0MHz/ USA (PAD07-US); 2. Wait for a while to re-try Detector cannot control 2. Same frequency the Switch interference RF Maximum Power +5dBm Transmission Range Minimum 40 m in door 100m outdoor line of sight Modulation Type FSK (Frequency-Shift Keying) ** Specifications are subject to change and improvement without notice. FCC ID : RHHPAD07 Disposal Warning: Do not use Non-Dimmable LED lamps. This marking indicates that this product should not be disposed with other household wastes throughout the EU. To prevent possible harm to the environment or human health from uncontrolled waste disposal, recycle it responsibly to promote the sustainable reuse of material DANGER Danger of electrocution! resources. To return your used device, please use the return and collection systems or contact the retailer where the product was All works on the device may be performed only by a qualified and licensed purchased. They can take this product for environmental safe recycling. electrician. Observe national regulations. Any works introducing changes into the configuration must be always performed with Company of License Holder:Philio Technology Corporation disconnected voltage. Address of License Holder:8F., No.653-2, Zhongzheng Rd., Xinzhuang Dist., New Taipei City Choosing a Suitable Location 24257, Taiwan(R.O.C) 1. Do not locate the Module facing direct sunlight, humid or dusty place. 2. The suitable ambient temperature for the Module is 0°C~40°C. FCC Interference Statement 3. Do not locate the Module where exists combustible substances or any source of This equipment has been tested and found to comply with the limits for a Class B digital de- heat, e.g. fires, radiators, boiler etc. vice, pursuant to Part 15 of the FCC Rules. 4. After putting it into use, the body of Module will become a little bit hot of which These limits are designed to provide reasonable protection against harmful interference in a phenomenon is normal. residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to Warning: radio communications. 1.Plug out to disconnect from power supply; Do not plug in line. However, there is no guarantee that interference will not occur in a particular installation. 2. Do not exceed the max rating. If this equipment does cause harmful interference to radio or television reception, which 3. Do not use Non-Dimmable LED lamps. can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one of the following measures: • Reorient or relocate the receiving antenna. • Increase the separation between the equipment and receiver. • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. • Consult the dealer or an experienced radio/TV technician for help. This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) This device must accept any interference received, including interference that may cause undesired operation. FCC Caution: Any changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate this equipment. This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter.
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.4 Linearized : No Page Count : 8 Language : zh-TW Creator : Writer Producer : LibreOffice 5.0 Create Date : 2017:02:08 16:41:16+08:00EXIF Metadata provided by EXIF.tools