Philio Technology PAN05 In Wall Single relay (1 way) switch User Manual BH002 RF ON OFF CONTROLLER

Philio Technology Corporation In Wall Single relay (1 way) switch BH002 RF ON OFF CONTROLLER

(PAN05-2) UserMan

PAN05-1/-2/-3 In Wall Single relay(1 way) switch moduleP     Fig 1. Assembling This in-wall switch module is a transceiver which is a Z-WaveTM enabled device and is fully compatible with any Z-WaveTM enabled network. Mini size design let the module can easily hide itself into the wall box and that will be good for the house decoration. There are many kind of application by using the module to switch Load On and Off ,one main application is the light control. If connect the com port directly to AC Lineterminal ,the new smart relay calibration technology can reduce the inrush currentcaused by the load and let the module work perfectly with many kind of light likeincandescent, fluorescent and LED light. This module can also connect to alternativepower supply like DC 12V to switch on/off 12V MR-16 light as follow picture.Adding to Z-WaveTM NetworkIn the front casing, there is an on/off button with LED indicator below which is used totoggle switch on and off or carries out inclusion, exclusion, reset or association. After being excluded, its LED flashes on and off alternately and repeatedly at 2-second in-tervals. It implies that it has not been assigned a node ID and cannot work with Z-Wave enabled devices.Auto InclusionThe function of auto inclusion will be executed as long as the in wall switch does not have Node ID and just connect the switch to main power.Note: Auto inclusion timeout is 2 minute during which the node information of explorer frame will be emitted once every 5 seconds.  Unlike “inclusion” function as 1
shown in the table below, the execution of auto inclusion is free from pressing the On/Off button on the Switch.The table below lists an operation summary of basic Z-Wave functions. Please refer to the instructions for your Z-WaveTM Certificated Primary Controller to access the Setup function, and to include/exclude/associate devicesFunction Description LED IndicationNo node ID The Z-Wave Controller does not allocatea node ID to the Switch.2-second on, 2-second offInclusion 1. Have Z-Wave Controller entered inclusion mode.One press one flash2.  Pressing Include button of PAN05 three times within 2 seconds will enter inclusion mode.Exclusion 1. Have Z-Wave Controller entered exclusion mode.One press one flash2. Pressing Include button of PAN05 three times within 2 seconds will enter exclusion mode.Node ID has been excluded. 2-second on, 2-second offReset 1. Pressing Include button of PAN05 three times within 2 seconds will enter inclusion mode.2. Within 1 second, press Include button of PAN05 again for 5 seconds until LED is off.3. IDs are excluded.Association 1. Have Z-Wave Controller entered association mode.Or  Pressing Include button of PAN05  three times within 2 seconds will enter association modeOne press one flash2.  There are only 1 group for the switch※Including a node ID allocated by Z-Wave Controller means inclusion.  Excluding a nodeID allocated by Z-Wave Controller means exclusion.※Failed or success in including/excluding the node ID can be viewed from the Z-Wave Controller. Sometimes people are not easy to execute exclusion or inclusion especially when PAN05 already installed in a wall box. To solve this issue, PAN05 support a special feature that can use S1 or S2 to execute “exclusion, inclusion, Reset or Association” at the first 3 minutes when first time connect to main power.  LED IndicationTo distinguish what mode the switch is in, view from the LED for identification.State Type LED IndicationNormal Whenever we switch On and off of the PAN05 by S1 S2 or On/Off button or RF command , the LED will lights up 1 second and then 2
off.No node ID Under normal operation, when the Switch has not been allocated a node ID, the LED flashes on and off alternately at 2-second intervals. By pressing S1 S2 or On/Off button, it will stop flashing temporarily. However, after disconnect and reconnect the Switch, the LED will flash on and off alternately at 2-second intervals.Learning When PAB01 is in learning mode, LED flashes on and offalternately and repeatedly at 0.5 second intervals.Choosing a Suitable Location1. Do not locate the Switch facing direct sunlight, humid or dusty place.2. The suitable ambient temperature for the Switch is 0°C~40°C.3. Do not locate the Switch where exists combustible substances or any source of heat, e.g. fires, radiators, boiler etc.4. After putting it into use, the body of Switch will become a little bit hot of which phenomenon is normal.Installation1. Put  the in wall switch into  a wall box  and connect the AC power wire L,N toPAN05 connector L, N.2. Connect the wall switch to the PAN05 as Fig1 .3. There  are  3   mode   PAN05  can   be   configured   to  match  different   kind  of   wallswitch, please refer to  3-1 Edge / Pulse / Edge-Toggle mode which describedin next section of this user manual. 4. If Edge-Toggle mode has been set, and the S1 S2 is connect to normal bi-stableswitch, every time when change the state of the wall switch will also swap thestate of Relay1.Programming1.  Basic Command Class / Binary Switch Command ClassThe Switch will respond to BASIC and BINARY commands that are part of the Z-3
Wave system.1-1 BASIC_GET / BINARY_SWITCH_GETBasic Get Command: [Command Class Basic, Basic Get]Basic Report Command:Report OFF: [Command Class Basic, Basic Report, Value = 0(0x00)]Report ON:[Command Class Basic, Basic Report, Value = (255)0xFF]Binary   Switch   Get   Command:[Command   Class   Switch   Binary,   SwitchBinary Get]Binary Switch Report Command:Report OFF:[Command Class Switch Binary, Switch Binary Report, Value =0(0x00)]Report ON:[Command Class Switch Binary, Switch Binary Report, Value = (255)0xFF]1-2 BASIC_SET / SWITCH_BINARY_SET [Command Class Basic, Basic Set, Value = (255)0xFF]: the load attached tothe Switch turns on.[Command Class Basic, Basic Set, Value = 0(0x00)]: the load attached tothe Switch turns off.[Command Class Switch Binary, Switch Binary Set, Value = (255)0xFF]:the load attached to the Switch turns on.[Command Class Switch Binary, Switch Binary Set, Value = 0(0x00)]: theload attached to the Switch turns off.2. Z-Wave’s Groups (Association Command Class Version 1)The Switch can be set to send reports to control associated Z-Wave devices.  It supports only one association group and the group has one node support. Group1 support SWITCH_BINARY_REPORT, BASIC_REPORT.For group 1, the Switch will report ON/OFF status of Relay1 2-1 Auto report to Grouping 1 (Maximum Node 1)2-1-1 On/Off Event Report       When “on” or “off ” state has been changed (ex. Press S1 S2 or include on/offbutton), it will send Binary Switch Report to the nodes of Group1.    Binary Switch ReportON:[Command Class Switch Binary, Switch Binary Report, Value =(255)0xFF]OFF:[Command Class Switch Binary, Switch Binary Report, Value =0(0x00)]2-1-2 Overload alarm report command      When PAN05 detect the overload, it  will send Alarm Report to the correspondGroup.  4
The content of Alarm ReportAlarm report command:[Command Class Alarm, Alarm Report, Alarm Type = 0x08, Alarm Level = 0xFF]3. Z-Wave’s ConfigurationConfigurationParameterFunction Size(Byte)Value Unit Default Description1 Edge orPulsemode orEdge-Toggle mode1 1-3 1 1:Edge mode2:Pulse mode3:Edge-Togglemode5 Restore switchstate mode1 0-2 1 0 : Switch Off1 : Last Switch State2 : Switch On6 Manual On/Off mode1 0-1 1 0:Disable manual On/Off1:Enable manual On/Off7 LED indicationmode1 1-2 1 1:Show switch state2:Show night mode8 Auto off timer1 0-0x7FFFSecond 00:Disable auto off function1-0x7FFF:1 ~ 32767seconds9 RF Off commandmode1 0-3 0 0:Switch off1:Ignore2:Switch toggle3:Switch on3-1 Edge / Pulse / Edge-Toggle modeManual switch S1 and S2 can set to Edge mode or Pulse mode or Edge-Toggle mode , default value is Edge mode.Edge mode: this mode is suitable for the bi stable wall switch that has indicator point on the switch, and the same position correspond to same state of relay1. if the PAN05 relay change the state because of receiving Z-Wave RF command, it may need two times of change (switch on to off  or  switch off to on) to let relay back to thecorrespond state. Manual switch S2 is disabled in this mode.Pulse mode: this mode is suitable for the toggle type wall switch to swap the state of Relay1.Edge-Toggle mode: this mode is suitable for the normal bi-stable switch, every time when change the state of the wall switch will also swap the state of Relay1.   3-2 Restore Switch State ModeWhenever the AC power reconnected to PAN05, it will set the switch to Off、On or Last switch state, default value is Last switch state. 3-3 Manual On/Off ModeThe On/Off function of S1、S2 and learn switch can be disabled or enabled by this parameter, default value is Enable. 5
3-4 LED indication ModeShow switch state:LED on for switch on and off for switch off.Show switch state:LED off for switch on and on for switch off.The default value is Show switch state. 3-5 Auto Off timerWhen auto off timer is equal to 0, the auto off function will be disabled. Whenever theswitch is set to on, the auto off timer begin to count down. After the timer counts to zero, PAN05 will switch off automatically. The default value is disable auto off function. 3-6 RF Off command modeWhenever a RF Off command is received, it could be interpreted as Switch Off、Switch On、Switch Toggle, or it would be ignored. The default value is Switch Off. 4. Command ClassesThe Switch supports Command Classes including…* COMMAND_CLASS_ZWAVEPLUS_INFO* COMMAND_CLASS_VERSION* COMMAND_CLASS_MANUFACTURER_SPECIFIC_V2* COMMAND_CLASS_DEVICE_RESET_LOCALLY* COMMAND_CLASS_ASSOCIATION_V2* COMMAND_CLASS_ASSOCIATION_GRP_INFO* COMMAND_CLASS_POWERLEVEL* COMMAND_CLASS_SWITCH_BINARY* COMMAND_CLASS_BASIC* COMMAND_CLASS_SWITCH_ALL* COMMAND_CLASS_CONFIGURATION* COMMAND_CLASS_ALARM* COMMAND_CLASS_SCENE_ACTIVATION* COMMAND_CLASS_SCENE_ACTUATOR_CONF* COMMAND_CLASS_PROTECTION* COMMAND_CLASS_FIRMWARE_UPDATE_MD_V2Troubleshooting                 Symptom Cause of Failure RecommendationThe Switch not working andLED off1. The Switch is not connect to the Main power2. The Switch break down1. Check power connections2. Don’t open up the Switch and send itfor repair.The Switch LED illuminating, but cannot control the ON/OFFSwitch of the load attachedCheck if the load connect into the Switch has its own ON/OFF switchSet the ON/OFF switch of the load attached to ONThe Switch LED illuminating, but the Detector cannot control1. Not carry out association2. Same frequency 1. Carry out association2. Wait for a while to re-try6
the Switch interferenceLED keep flashing continuously, but cannot controlOverload occurs Remove the load attached or check max. load cannot exceed 11A(230Vac/120Vac)SpecificationOperating Voltage 100 ~240VACMaximum Load 11A(230Vac/120Vac)Range Minimum 30 m in door 100m outdoor  line of sightOperating Temperature 0°C ~ 40°CFrequency Range PAN05-1: 868.40MHz; 869.85MHz(EU) /PAN05-2  908.40MHz; 916.00MHz(USA/Canada) / PAN05-3  922.5MHz/ 923.9MHz/ 926.3MHz (Taiwan/JP)** Specifications are subject to change and improvement without notice.                                                                           FCC ID : RHHPAN05 Warning:1.Plug out to disconnect from power supply; Do not plug in line. 2. Do not exceed the max rating Disposal This marking indicates that this product should not be disposed with other household wastes throughout the EU. To prevent possible harm tothe environment or human health from uncontrolled waste disposal, recycle it responsibly to promote the sustainable reuse of material resources. To return your used device, please use the return and collection systems or contact the retailer where the product was purchased. They can take this product for environmental safe recycling.Company of License Holder:Philio Technology CorporationAddress of License Holder:8F.,No.653-2,Zhongzheng Rd., Xinzhuang Dist., New Taipei City 24257,Taiwan(R.O.C)  FCC Interference StatementThis equipment has been tested and found to comply with the limits fora Class B digital device, pursuant to Part 15 of the FCC Rules. Theselimits are designed to provide reasonable protection against harmfulinterference in a residential installation. This equipment generates, usesand can radiate radio frequency energy and, if not installed and usedin accordance with the instructions, may cause harmful interference toradio communications. However, there is no guarantee thatinterference will not occur in a particular installation. If this equipmentdoes cause harmful interference to radio or television reception, whichcan be determined by turning the equipment off and on, the user is7
encouraged to try to correct the interference by one of the followingmeasures:• Reorient or relocate the receiving antenna.• Increase the separation between the equipment and receiver.• Connect the equipment into an outlet on a circuit different fromthat to which the receiver is connected.• Consult the dealer or an experienced radio/TV technician forhelp.This device complies with Part 15 of the FCC Rules. Operation is subjectto the following two conditions:(1) This device may not cause harmful interference, and(2) This device must accept any interference received, includinginterference that may cause undesired operation.FCC Caution: Any changes or modifications not expressly approved bythe party responsible for compliance could void the user's authority tooperate this equipment.This transmitter must not be co-located or operating in conjunctionwith any other antenna or transmitter.8