Philio Technology PAN05 In Wall Single relay (1 way) switch User Manual BH002 RF ON OFF CONTROLLER

Philio Technology Corporation In Wall Single relay (1 way) switch BH002 RF ON OFF CONTROLLER

(PAN05-2) UserMan

Download: Philio Technology PAN05 In Wall Single relay (1 way) switch User Manual BH002  RF ON OFF CONTROLLER
Mirror Download [FCC.gov]Philio Technology PAN05 In Wall Single relay (1 way) switch User Manual BH002  RF ON OFF CONTROLLER
Document ID2409992
Application IDlpAPBwR3Wv1RwB/GhIb0TQ==
Document Description(PAN05-2) UserMan
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize14.53kB (181579 bits)
Date Submitted2014-10-03 00:00:00
Date Available2014-10-03 00:00:00
Creation Date2014-07-02 13:44:01
Producing SoftwareLibreOffice 4.1
Document Lastmod0000-00-00 00:00:00
Document TitleBH002 RF ON/OFF CONTROLLER
Document CreatorWriter
Document Author: .

PAN05-1/-2/-3 In Wall Single relay(1 way) switch module
There are many kind of application by using the module to switch Load On and Off ,
one main application is the light control. If connect the com port directly to AC Line
terminal ,the new smart relay calibration technology can reduce the inrush current
caused by the load and let the module work perfectly with many kind of light like
incandescent, fluorescent and LED light. This module can also connect to alternative
power supply like DC 12V to switch on/off 12V MR-16 light as follow picture.
Adding to Z-WaveTM Network
In the front casing, there is an on/off button with LED indicator below which is used to
toggle switch on and off or carries out inclusion, exclusion, reset or association. After
being excluded, its LED flashes on and off alternately and repeatedly at 2-second intervals. It implies that it has not been assigned a node ID and cannot work with ZWave enabled devices.
Auto Inclusion
Fig 1. Assembling
The function of auto inclusion will be executed as long as the in wall switch does not
This in-wall switch module is a transceiver which is a Z-WaveTM enabled device and
have Node ID and just connect the switch to main power.
is fully compatible with any Z-WaveTM enabled network. Mini size design let the
module can easily hide itself into the wall box and that will be good for the house
Note: Auto inclusion timeout is 2 minute during which the node information of
decoration.
explorer frame will be emitted once every 5 seconds. Unlike “inclusion” function as
shown in the table below, the execution of auto inclusion is free from pressing the
seconds until LED is off.
On/Off button on the Switch.
Association
The table below lists an operation summary of basic Z-Wave functions. Please refer
3.
IDs are excluded.
1.
Have Z-Wave Controller entered
One press one flash
association mode.
to the instructions for your Z-WaveTM Certificated Primary Controller to access the
Or Pressing Include button of PAN05
Setup function, and to include/exclude/associate devices
three times within 2 seconds will
Function
Description
LED Indication
No node ID
The Z-Wave Controller does not allocate
2-second on, 2-second off
enter association mode
2. There are only 1 group for the switch
a node ID to the Switch.
Inclusion
1.
Have Z-Wave Controller entered
※Including a node ID allocated by Z-Wave Controller means inclusion.
One press one flash
Excluding a node
ID allocated by Z-Wave Controller means exclusion.
inclusion mode.
※Failed or success in including/excluding the node ID can be viewed from the Z-Wave
2. Pressing Include button of PAN05
Controller.
three times within 2 seconds will
enter inclusion mode.
Exclusion
1.
2.
Have Z-Wave Controller entered
Sometimes people are not easy to execute exclusion or inclusion especially when
One press one flash
exclusion mode.
PAN05 already installed in a wall box. To solve this issue, PAN05 support a special
Pressing Include button of PAN05
feature that can use S1 or S2 to execute “exclusion, inclusion, Reset or Association”
three times within 2 seconds will
at the first 3 minutes when first time connect to main power.
enter exclusion mode.
Node ID has been excluded.
Reset
1.
LED Indication
2-second on, 2-second off
To distinguish what mode the switch is in, view from the LED for identification.
Pressing Include button of PAN05
three times within 2 seconds will
2.
enter inclusion mode.
State Type
LED Indication
Within 1 second, press Include
Normal
Whenever we switch On and off of the PAN05 by S1 S2 or On/Off
button or RF command , the LED will lights up 1 second and then
button of PAN05 again for 5
off.
No node ID
Under normal operation, when the Switch has not been allocated a
node ID, the LED flashes on and off alternately at 2-second
intervals. By pressing S1 S2 or On/Off button, it will stop flashing
temporarily. However, after disconnect and reconnect the Switch,
the LED will flash on and off alternately at 2-second intervals.
Learning
When PAB01 is in learning mode, LED flashes on and off
alternately and repeatedly at 0.5 second intervals.
Choosing a Suitable Location
1. Do not locate the Switch facing direct sunlight, humid or dusty place.
2. The suitable ambient temperature for the Switch is 0°C~40°C.
1. Put the in wall switch into a wall box and connect the AC power wire L,N to
3. Do not locate the Switch where exists combustible substances or any source of
PAN05 connector L, N.
heat, e.g. fires, radiators, boiler etc.
2. Connect the wall switch to the PAN05 as Fig1 .
4. After putting it into use, the body of Switch will become a little bit hot of which
3. There are 3 mode PAN05 can be configured to match different kind of wall
phenomenon is normal.
switch, please refer to 3-1 Edge / Pulse / Edge-Toggle mode which described
in next section of this user manual.
Installation
4. If Edge-Toggle mode has been set, and the S1 S2 is connect to normal bi-stable
switch, every time when change the state of the wall switch will also swap the
state of Relay1.
Programming
1. Basic Command Class / Binary Switch Command Class
The Switch will respond to BASIC and BINARY commands that are part of the Z3
Wave system.
load attached to the Switch turns off.
1-1 BASIC_GET / BINARY_SWITCH_GET
2. Z-Wave’s Groups (Association Command Class Version 1)
Basic Get Command: [Command Class Basic, Basic Get]
The Switch can be set to send reports to control associated Z-Wave devices. It
Basic Report Command:
supports only one association group and the group has one node support. Group1
Report OFF: [Command Class Basic, Basic Report, Value = 0(0x00)]
support SWITCH_BINARY_REPORT, BASIC_REPORT.
Report ON:[Command Class Basic, Basic Report, Value = (255)0xFF]
For group 1, the Switch will report ON/OFF status of Relay1
Binary Switch Get Command:[Command Class Switch Binary, Switch
2-1 Auto report to Grouping 1 (Maximum Node 1)
Binary Get]
Binary Switch Report Command:
Report OFF:[Command Class Switch Binary, Switch Binary Report, Value
2-1-1 On/Off Event Report
=0(0x00)]
When “on” or “off ” state has been changed (ex. Press S1 S2 or include on/off
Report ON:[Command Class Switch Binary, Switch Binary Report, Value =
button), it will send Binary Switch Report to the nodes of Group1.
(255)0xFF]
Binary Switch Report
1-2 BASIC_SET / SWITCH_BINARY_SET
ON:[Command Class Switch Binary, Switch Binary Report, Value
=(255)0xFF]
[Command Class Basic, Basic Set, Value = (255)0xFF]: the load attached to
the Switch turns on.
OFF:[Command Class Switch Binary, Switch Binary Report, Value
[Command Class Basic, Basic Set, Value = 0(0x00)]: the load attached to
=0(0x00)]
the Switch turns off.
2-1-2 Overload alarm report command
[Command Class Switch Binary, Switch Binary Set, Value = (255)0xFF]:
the load attached to the Switch turns on.
When PAN05 detect the overload, it will send Alarm Report to the correspond
[Command Class Switch Binary, Switch Binary Set, Value = 0(0x00)]: the
Group.
8
The content of Alarm Report
Auto off
timer
Alarm report command:[Command Class Alarm, Alarm Report, Alarm Type
RF Off
0-
Second
0x7FFF
0-3
command
= 0x08, Alarm Level = 0xFF]
mode
0:Disable auto
off function
1-0x7FFF:1 ~
32767seconds
0:Switch off
1:Ignore
2:Switch toggle
3:Switch on
3-1 Edge / Pulse / Edge-Toggle mode
3. Z-Wave’s Configuration
Manual switch S1 and S2 can set to Edge mode or Pulse mode or Edge-Toggle
Configuration
Function
Parameter
Size
Value
Unit
Default
mode , default value is Edge mode.
Description
(Byte)
Edge or
Edge mode: this mode is suitable for the bi stable wall switch that has indicator point
1-3
1:Edge mode
on the switch, and the same position correspond to same state of relay1. if the
Pulse
2:Pulse mode
PAN05 relay change the state because of receiving Z-Wave RF command, it may
mode or
3:Edge-Toggle
need two times of change (switch on to off or switch off to on) to let relay back to the
Edge-Tog
mode
correspond state. Manual switch S2 is disabled in this mode.
gle mode
Restore
Pulse mode: this mode is suitable for the toggle type wall switch to swap the state of
0-2
switch
0-1
mode
LED
indication
mode
when change the state of the wall switch will also swap the state of Relay1.
2 : Switch On
On/Off
Edge-Toggle mode: this mode is suitable for the normal bi-stable switch, every time
State
mode
Manual
Relay1.
1 : Last Switch
state
0 : Switch Off
0:Disable
manual On/Off
1:Enable
manual On/Off
3-2 Restore Switch State Mode
Whenever the AC power reconnected to PAN05, it will set the switch to Off、On or
Last switch state, default value is Last switch state.
1-2
1:Show switch
state
2:Show night
mode
3-3 Manual On/Off Mode
The On/Off function of S1、S2 and learn switch can be disabled or enabled by this
parameter, default value is Enable.
3-4 LED indication Mode
* COMMAND_CLASS_SWITCH_BINARY
Show switch state:LED on for switch on and off for switch off.
* COMMAND_CLASS_BASIC
* COMMAND_CLASS_SWITCH_ALL
Show switch state:LED off for switch on and on for switch off.
* COMMAND_CLASS_CONFIGURATION
The default value is Show switch state.
* COMMAND_CLASS_ALARM
3-5 Auto Off timer
* COMMAND_CLASS_SCENE_ACTIVATION
* COMMAND_CLASS_SCENE_ACTUATOR_CONF
When auto off timer is equal to 0, the auto off function will be disabled. Whenever the
* COMMAND_CLASS_PROTECTION
switch is set to on, the auto off timer begin to count down. After the timer counts to
* COMMAND_CLASS_FIRMWARE_UPDATE_MD_V2
zero, PAN05 will switch off automatically. The default value is disable auto off
function.
3-6 RF Off command mode
Troubleshooting
Whenever a RF Off command is received, it could be interpreted as Switch
Off、Switch On、Switch Toggle, or it would be ignored. The default value is Switch Off.
4.
Symptom
Cause of Failure
Recommendation
The Switch not working and 1. The Switch is not
1. Check power connections
LED off
2. Don’t open up the Switch and send it
connect to the Main
power
Command Classes
for repair.
2. The Switch break
down
The Switch supports Command Classes including…
* COMMAND_CLASS_ZWAVEPLUS_INFO
The Switch LED
Check if the load connect Set the ON/OFF switch of the load
* COMMAND_CLASS_VERSION
illuminating, but cannot
into the Switch has its
* COMMAND_CLASS_MANUFACTURER_SPECIFIC_V2
control the ON/OFF
own ON/OFF switch
* COMMAND_CLASS_DEVICE_RESET_LOCALLY
Switch of the load attached
* COMMAND_CLASS_ASSOCIATION_V2
The Switch LED
* COMMAND_CLASS_ASSOCIATION_GRP_INFO
illuminating, but the
* COMMAND_CLASS_POWERLEVEL
Detector cannot control
1. Not carry out
association
2. Same frequency
attached to ON
1. Carry out association
2. Wait for a while to re-try
the Switch
Disposal
interference
Remove the load attached or check
This marking indicates that this product should not be disposed with
continuously, but cannot
max. load cannot exceed
other household wastes throughout the EU. To prevent possible harm to
control
11A(230Vac/120Vac)
the environment or human health from uncontrolled waste disposal,
LED keep flashing
Overload occurs
recycle it responsibly to promote the sustainable reuse of material
resources. To return your used device, please use the return and
Specification
collection systems or contact the retailer where the product was
Operating Voltage
100 ~240VAC
Maximum Load
11A(230Vac/120Vac)
Range
Minimum 30 m in door 100m outdoor line of sight
purchased. They can take this product for environmental safe recycling.
Company of License Holder:Philio Technology Corporation
Operating Temperature 0°C ~ 40°C
Address of License Holder:8F.,No.653-2,Zhongzheng Rd., Xinzhuang Dist., New
Frequency Range
Taipei City 24257,Taiwan(R.O.C)
PAN05-1: 868.40MHz; 869.85MHz(EU) /
PAN05-2 908.40MHz; 916.00MHz(USA/Canada) /
PAN05-3 922.5MHz/ 923.9MHz/ 926.3MHz (Taiwan/JP)
** Specifications are subject to change and improvement without notice.
FCC Interference Statement
This equipment has been tested and found to comply with the limits for
a Class B digital device, pursuant to Part 15 of the FCC Rules. These
limits are designed to provide reasonable protection against harmful
interference in a residential installation. This equipment generates, uses
FCC ID : RHHPAN05
and can radiate radio frequency energy and, if not installed and used
in accordance with the instructions, may cause harmful interference to
Warning:
radio communications. However, there is no guarantee that
1.Plug out to disconnect from power supply; Do not plug in line.
interference will not occur in a particular installation. If this equipment
2. Do not exceed the max rating
does cause harmful interference to radio or television reception, which
can be determined by turning the equipment off and on, the user is
encouraged to try to correct the interference by one of the following
measures:
• Reorient or relocate the receiving antenna.
• Increase the separation between the equipment and receiver.
• Connect the equipment into an outlet on a circuit different from
that to which the receiver is connected.
• Consult the dealer or an experienced radio/TV technician for
help.
This device complies with Part 15 of the FCC Rules. Operation is subject
to the following two conditions:
(1) This device may not cause harmful interference, and
(2) This device must accept any interference received, including
interference that may cause undesired operation.
FCC Caution: Any changes or modifications not expressly approved by
the party responsible for compliance could void the user's authority to
operate this equipment.
This transmitter must not be co-located or operating in conjunction
with any other antenna or transmitter.

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.4
Linearized                      : No
Page Count                      : 8
Language                        : zh-TW
Title                           : BH002  RF ON/OFF CONTROLLER
Author                          : .
Creator                         : Writer
Producer                        : LibreOffice 4.1
Create Date                     : 2014:07:02 13:44:01+08:00
EXIF Metadata provided by EXIF.tools
FCC ID Filing: RHHPAN05

Navigation menu