Philio Technology PAN05 In Wall Single relay (1 way) switch User Manual BH002 RF ON OFF CONTROLLER
Philio Technology Corporation In Wall Single relay (1 way) switch BH002 RF ON OFF CONTROLLER
(PAN05-2) UserMan
PAN05-1/-2/-3 In Wall Single relay(1 way) switch module There are many kind of application by using the module to switch Load On and Off , one main application is the light control. If connect the com port directly to AC Line terminal ,the new smart relay calibration technology can reduce the inrush current caused by the load and let the module work perfectly with many kind of light like incandescent, fluorescent and LED light. This module can also connect to alternative power supply like DC 12V to switch on/off 12V MR-16 light as follow picture. Adding to Z-WaveTM Network In the front casing, there is an on/off button with LED indicator below which is used to toggle switch on and off or carries out inclusion, exclusion, reset or association. After being excluded, its LED flashes on and off alternately and repeatedly at 2-second intervals. It implies that it has not been assigned a node ID and cannot work with ZWave enabled devices. Auto Inclusion Fig 1. Assembling The function of auto inclusion will be executed as long as the in wall switch does not This in-wall switch module is a transceiver which is a Z-WaveTM enabled device and have Node ID and just connect the switch to main power. is fully compatible with any Z-WaveTM enabled network. Mini size design let the module can easily hide itself into the wall box and that will be good for the house Note: Auto inclusion timeout is 2 minute during which the node information of decoration. explorer frame will be emitted once every 5 seconds. Unlike “inclusion” function as shown in the table below, the execution of auto inclusion is free from pressing the seconds until LED is off. On/Off button on the Switch. Association The table below lists an operation summary of basic Z-Wave functions. Please refer 3. IDs are excluded. 1. Have Z-Wave Controller entered One press one flash association mode. to the instructions for your Z-WaveTM Certificated Primary Controller to access the Or Pressing Include button of PAN05 Setup function, and to include/exclude/associate devices three times within 2 seconds will Function Description LED Indication No node ID The Z-Wave Controller does not allocate 2-second on, 2-second off enter association mode 2. There are only 1 group for the switch a node ID to the Switch. Inclusion 1. Have Z-Wave Controller entered ※Including a node ID allocated by Z-Wave Controller means inclusion. One press one flash Excluding a node ID allocated by Z-Wave Controller means exclusion. inclusion mode. ※Failed or success in including/excluding the node ID can be viewed from the Z-Wave 2. Pressing Include button of PAN05 Controller. three times within 2 seconds will enter inclusion mode. Exclusion 1. 2. Have Z-Wave Controller entered Sometimes people are not easy to execute exclusion or inclusion especially when One press one flash exclusion mode. PAN05 already installed in a wall box. To solve this issue, PAN05 support a special Pressing Include button of PAN05 feature that can use S1 or S2 to execute “exclusion, inclusion, Reset or Association” three times within 2 seconds will at the first 3 minutes when first time connect to main power. enter exclusion mode. Node ID has been excluded. Reset 1. LED Indication 2-second on, 2-second off To distinguish what mode the switch is in, view from the LED for identification. Pressing Include button of PAN05 three times within 2 seconds will 2. enter inclusion mode. State Type LED Indication Within 1 second, press Include Normal Whenever we switch On and off of the PAN05 by S1 S2 or On/Off button or RF command , the LED will lights up 1 second and then button of PAN05 again for 5 off. No node ID Under normal operation, when the Switch has not been allocated a node ID, the LED flashes on and off alternately at 2-second intervals. By pressing S1 S2 or On/Off button, it will stop flashing temporarily. However, after disconnect and reconnect the Switch, the LED will flash on and off alternately at 2-second intervals. Learning When PAB01 is in learning mode, LED flashes on and off alternately and repeatedly at 0.5 second intervals. Choosing a Suitable Location 1. Do not locate the Switch facing direct sunlight, humid or dusty place. 2. The suitable ambient temperature for the Switch is 0°C~40°C. 1. Put the in wall switch into a wall box and connect the AC power wire L,N to 3. Do not locate the Switch where exists combustible substances or any source of PAN05 connector L, N. heat, e.g. fires, radiators, boiler etc. 2. Connect the wall switch to the PAN05 as Fig1 . 4. After putting it into use, the body of Switch will become a little bit hot of which 3. There are 3 mode PAN05 can be configured to match different kind of wall phenomenon is normal. switch, please refer to 3-1 Edge / Pulse / Edge-Toggle mode which described in next section of this user manual. Installation 4. If Edge-Toggle mode has been set, and the S1 S2 is connect to normal bi-stable switch, every time when change the state of the wall switch will also swap the state of Relay1. Programming 1. Basic Command Class / Binary Switch Command Class The Switch will respond to BASIC and BINARY commands that are part of the Z3 Wave system. load attached to the Switch turns off. 1-1 BASIC_GET / BINARY_SWITCH_GET 2. Z-Wave’s Groups (Association Command Class Version 1) Basic Get Command: [Command Class Basic, Basic Get] The Switch can be set to send reports to control associated Z-Wave devices. It Basic Report Command: supports only one association group and the group has one node support. Group1 Report OFF: [Command Class Basic, Basic Report, Value = 0(0x00)] support SWITCH_BINARY_REPORT, BASIC_REPORT. Report ON:[Command Class Basic, Basic Report, Value = (255)0xFF] For group 1, the Switch will report ON/OFF status of Relay1 Binary Switch Get Command:[Command Class Switch Binary, Switch 2-1 Auto report to Grouping 1 (Maximum Node 1) Binary Get] Binary Switch Report Command: Report OFF:[Command Class Switch Binary, Switch Binary Report, Value 2-1-1 On/Off Event Report =0(0x00)] When “on” or “off ” state has been changed (ex. Press S1 S2 or include on/off Report ON:[Command Class Switch Binary, Switch Binary Report, Value = button), it will send Binary Switch Report to the nodes of Group1. (255)0xFF] Binary Switch Report 1-2 BASIC_SET / SWITCH_BINARY_SET ON:[Command Class Switch Binary, Switch Binary Report, Value =(255)0xFF] [Command Class Basic, Basic Set, Value = (255)0xFF]: the load attached to the Switch turns on. OFF:[Command Class Switch Binary, Switch Binary Report, Value [Command Class Basic, Basic Set, Value = 0(0x00)]: the load attached to =0(0x00)] the Switch turns off. 2-1-2 Overload alarm report command [Command Class Switch Binary, Switch Binary Set, Value = (255)0xFF]: the load attached to the Switch turns on. When PAN05 detect the overload, it will send Alarm Report to the correspond [Command Class Switch Binary, Switch Binary Set, Value = 0(0x00)]: the Group. 8 The content of Alarm Report Auto off timer Alarm report command:[Command Class Alarm, Alarm Report, Alarm Type RF Off 0- Second 0x7FFF 0-3 command = 0x08, Alarm Level = 0xFF] mode 0:Disable auto off function 1-0x7FFF:1 ~ 32767seconds 0:Switch off 1:Ignore 2:Switch toggle 3:Switch on 3-1 Edge / Pulse / Edge-Toggle mode 3. Z-Wave’s Configuration Manual switch S1 and S2 can set to Edge mode or Pulse mode or Edge-Toggle Configuration Function Parameter Size Value Unit Default mode , default value is Edge mode. Description (Byte) Edge or Edge mode: this mode is suitable for the bi stable wall switch that has indicator point 1-3 1:Edge mode on the switch, and the same position correspond to same state of relay1. if the Pulse 2:Pulse mode PAN05 relay change the state because of receiving Z-Wave RF command, it may mode or 3:Edge-Toggle need two times of change (switch on to off or switch off to on) to let relay back to the Edge-Tog mode correspond state. Manual switch S2 is disabled in this mode. gle mode Restore Pulse mode: this mode is suitable for the toggle type wall switch to swap the state of 0-2 switch 0-1 mode LED indication mode when change the state of the wall switch will also swap the state of Relay1. 2 : Switch On On/Off Edge-Toggle mode: this mode is suitable for the normal bi-stable switch, every time State mode Manual Relay1. 1 : Last Switch state 0 : Switch Off 0:Disable manual On/Off 1:Enable manual On/Off 3-2 Restore Switch State Mode Whenever the AC power reconnected to PAN05, it will set the switch to Off、On or Last switch state, default value is Last switch state. 1-2 1:Show switch state 2:Show night mode 3-3 Manual On/Off Mode The On/Off function of S1、S2 and learn switch can be disabled or enabled by this parameter, default value is Enable. 3-4 LED indication Mode * COMMAND_CLASS_SWITCH_BINARY Show switch state:LED on for switch on and off for switch off. * COMMAND_CLASS_BASIC * COMMAND_CLASS_SWITCH_ALL Show switch state:LED off for switch on and on for switch off. * COMMAND_CLASS_CONFIGURATION The default value is Show switch state. * COMMAND_CLASS_ALARM 3-5 Auto Off timer * COMMAND_CLASS_SCENE_ACTIVATION * COMMAND_CLASS_SCENE_ACTUATOR_CONF When auto off timer is equal to 0, the auto off function will be disabled. Whenever the * COMMAND_CLASS_PROTECTION switch is set to on, the auto off timer begin to count down. After the timer counts to * COMMAND_CLASS_FIRMWARE_UPDATE_MD_V2 zero, PAN05 will switch off automatically. The default value is disable auto off function. 3-6 RF Off command mode Troubleshooting Whenever a RF Off command is received, it could be interpreted as Switch Off、Switch On、Switch Toggle, or it would be ignored. The default value is Switch Off. 4. Symptom Cause of Failure Recommendation The Switch not working and 1. The Switch is not 1. Check power connections LED off 2. Don’t open up the Switch and send it connect to the Main power Command Classes for repair. 2. The Switch break down The Switch supports Command Classes including… * COMMAND_CLASS_ZWAVEPLUS_INFO The Switch LED Check if the load connect Set the ON/OFF switch of the load * COMMAND_CLASS_VERSION illuminating, but cannot into the Switch has its * COMMAND_CLASS_MANUFACTURER_SPECIFIC_V2 control the ON/OFF own ON/OFF switch * COMMAND_CLASS_DEVICE_RESET_LOCALLY Switch of the load attached * COMMAND_CLASS_ASSOCIATION_V2 The Switch LED * COMMAND_CLASS_ASSOCIATION_GRP_INFO illuminating, but the * COMMAND_CLASS_POWERLEVEL Detector cannot control 1. Not carry out association 2. Same frequency attached to ON 1. Carry out association 2. Wait for a while to re-try the Switch Disposal interference Remove the load attached or check This marking indicates that this product should not be disposed with continuously, but cannot max. load cannot exceed other household wastes throughout the EU. To prevent possible harm to control 11A(230Vac/120Vac) the environment or human health from uncontrolled waste disposal, LED keep flashing Overload occurs recycle it responsibly to promote the sustainable reuse of material resources. To return your used device, please use the return and Specification collection systems or contact the retailer where the product was Operating Voltage 100 ~240VAC Maximum Load 11A(230Vac/120Vac) Range Minimum 30 m in door 100m outdoor line of sight purchased. They can take this product for environmental safe recycling. Company of License Holder:Philio Technology Corporation Operating Temperature 0°C ~ 40°C Address of License Holder:8F.,No.653-2,Zhongzheng Rd., Xinzhuang Dist., New Frequency Range Taipei City 24257,Taiwan(R.O.C) PAN05-1: 868.40MHz; 869.85MHz(EU) / PAN05-2 908.40MHz; 916.00MHz(USA/Canada) / PAN05-3 922.5MHz/ 923.9MHz/ 926.3MHz (Taiwan/JP) ** Specifications are subject to change and improvement without notice. FCC Interference Statement This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses FCC ID : RHHPAN05 and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to Warning: radio communications. However, there is no guarantee that 1.Plug out to disconnect from power supply; Do not plug in line. interference will not occur in a particular installation. If this equipment 2. Do not exceed the max rating does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one of the following measures: • Reorient or relocate the receiving antenna. • Increase the separation between the equipment and receiver. • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. • Consult the dealer or an experienced radio/TV technician for help. This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) This device must accept any interference received, including interference that may cause undesired operation. FCC Caution: Any changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate this equipment. This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter.
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.4 Linearized : No Page Count : 8 Language : zh-TW Title : BH002 RF ON/OFF CONTROLLER Author : . Creator : Writer Producer : LibreOffice 4.1 Create Date : 2014:07:02 13:44:01+08:00EXIF Metadata provided by EXIF.tools