Philio Technology PAN06 IN Wall Watch User Manual BH002 RF ON OFF CONTROLLER

Philio Technology Corporation IN Wall Watch BH002 RF ON OFF CONTROLLER

(PAN06-2) UserMan

PAN06-1/-2/-3 In Wall Dual relay(1 way) switch moduleP       Fig 1. Assembling This in-wall switch module is a transceiver which is a Z-WaveTM enabled device and is fully compatible with any Z-WaveTM enabled network. Mini size design let the module can easily hide itself into the wall box and that will be good for the house decoration. There are many kind of application by using the module to switch Load On and Off , one main applicationis the light control. If connect the com port directly to AC Line terminal ,the new smart relay calibrationtechnology can reduce the inrush current caused by the load and let the module work perfectly with manykind of light like incandescent, fluorescent and LED light. This module can also connect to alternativepower supply like DC 12V to switch on/off 12V MR-16 light as follow picture.Adding to Z-WaveTM NetworkIn the front casing, there is an on/off button with LED indicator below which is used totoggle switch   on   and  off or carries out inclusion, exclusion, reset or association.When first power is applied, its LED flashes on and off alternately and repeatedly at2-second intervals. It implies that it has not been assigned a node ID and cannotwork with Z-Wave enabled devices. Auto InclusionThe function of auto inclusion will be executed as long as the in wall switch does not have Node ID and just connect the switch to main power.Note: Auto inclusion timeout is 4 minute during which the node information of explorer frame will be emitted once every 5 seconds.  Unlike “inclusion” function as shown in the table below, the execution of auto inclusion is free from pressing the On/Off button on the Switch.1
The table below lists an operation summary of basic Z-Wave functions. Please refer to the instructions for your Z-WaveTM Certificated Primary Controller to access the Setup function, and to include/exclude/associate devicesFunction Description LED IndicationNo node ID The Z-Wave Controller does not allocatea node ID to the Switch.2-second on, 2-second offInclusion 1. Have Z-Wave Controller entered inclusion mode.One press one flash2.  Pressing Include button of PAN06 three times within 1.5 seconds will enter inclusion mode.Exclusion 1. Have Z-Wave Controller entered exclusion mode.One press one flash2. Pressing Include button of PAN06 three times within 1.5 seconds will enter exclusion mode.Node ID has been excluded. 2-second on, 2-second offReset 1. Pressing Include button of PAN06 three times within 1.5 seconds will enter inclusion mode.One press one flash2. Within 1 second, press Include button of PAN06 again for 5 seconds until LED is off.3. IDs are excluded. 2-second on, 2-second offAssociation 1. Have Z-Wave Controller entered association mode.Or  Pressing Include button of PAN06  three times within 1.5 seconds will enter association modeOne press one flash2.  There are 3 groups for the switch※Including a node ID allocated by Z-Wave Controller means inclusion.  Excluding a nodeID allocated by Z-Wave Controller means exclusion.※Failed or success in including/excluding the node ID can be viewed from the Z-Wave Controller. Sometimes people are not easy to execute exclusion or inclusion especially when PAN06 already installed in a wall box. To solve this issue, PAN06 support a special feature that can use S1 or S2 to execute “exclusion, inclusion, Reset or Association” at the first 3 minutes when first time connect to main power.  LED IndicationTo distinguish what mode the switch is in, view from the LED for identification.State Type LED IndicationNormal Whenever we switch On and off of the PAN06 by S1 S2 or On/Off button or RF command , the LED will lights up 1 second and then off.No node ID Under normal operation, when the Switch has not been allocated anode ID, the LED flashes on and off alternately at 2-second intervals. By pressing S1 S2 or On/Off button, it will stop flashing 2
temporarily. However, after disconnect and reconnect the Switch, the LED will flash on and off alternately at 2-second intervals.Choosing a Suitable Location1. Do not locate the Switch facing direct sunlight, humid or dusty place.2. The suitable ambient temperature for the Switch is 0°C~40°C.3. Do not locate the Switch where exists combustible substances or any source of heat, e.g. fires, radiators, boiler etc.4. After putting it into use, the body of Switch will become a little bit hot of which phenomenon is normal.Installation1. Put the in wall switch into a wall box and connect  the AC power wire L,N toPAN06 connector L, N.2. Connect the wall switch to the PAN06 as Fig1 .3. There  are   3   mode   PAN06   can   be   configured  to  match  different   kind  of   wallswitch, please refer to  3-2 Edge / Pulse / Edge-Toggle mode which describedin next section of this user manual 4. If Edge-Toggle mode has been set, and the S1 S2 is connect to normal bi-stableswitch, every time when change the state of the wall switch will also swap thestate of Relay1 or Relay2Programming1.  Basic Command Class / Binary Switch Command ClassThe Switch will respond to BASIC and BINARY commands that are part of the Z-Wave system.1-1 BASIC_GET / BINARY_SWITCH_GETSince the switch have two relay, the Switch will report its On/Off state to theController by setting Configuration parameter 1.Configuration parameter 1=1(default) Report ON either relay 1 ON or relay 2ON 3
  Report OFF when both relay 1 and relay 2 OFFConfiguration parameter 1=2 Report ON when relay 1 ON   Report OFF when relay 1 OFFConfiguration parameter 1=3 Report ON when relay 2 ON   Report OFF when relay 2 OFF    Basic Get Command: [Command Class Basic, Basic Get]Basic Report Command:Report OFF: [Command Class Basic, Basic Report, Value = 0(0x00)]Report ON:[Command Class Basic, Basic Report, Value = (255)0xFF]Binary   Switch   Get   Command:[Command   Class   Switch   Binary,   SwitchBinary Get]Binary Switch Report Command:Report OFF:[Command Class Switch Binary, Switch Binary Report, Value =0(0x00)]Report ON:[Command Class Switch Binary, Switch Binary Report, Value =(255)0xFF]1-2 BASIC_SET / SWITCH_BINARY_SETSince the switch have two relay, the load attached to the Switch will turn on oroff upon receipt of the following commands from a Z-Wave Controller by settingConfiguration parameter 1.Configuration  parameter   1=1(default)   switch ON   and   OFF  both   relay  1   andrelay 2 Configuration parameter 1=2 switch ON and OFF of relay 1  Configuration parameter 1=3 switch ON and OFF of relay 2  , [Command Class Basic, Basic Set, Value = (255)0xFF]: the load attached tothe Switch turns on.[Command Class Basic, Basic Set, Value = 0(0x00)]: the load attached tothe Switch turns off.[Command Class Switch Binary, Switch Binary Set, Value = (255)0xFF]:the load attached to the Switch turns on.[Command Class Switch Binary, Switch Binary Set, Value = 0(0x00)]: theload attached to the Switch turns off.2. Z-Wave’s Groups (Association Command Class Version 1)The Switch can be set to send reports to control associated Z-Wave devices.  It supports 3 association groups which every group has one node support. Group1~Group3 support SWITCH_BINARY_REPORT.For group 1, the Switch will report ON/OFF status of Relay1 and Relay2 For group 2, the Switch will report ON/OFF status of Relay1 For group 3, the Switch will report ON/OFF status of Relay2 2-1 Auto report to Grouping 1 ~3(Maximum Node 1)4
2-1-1 On/Off Event Report       When “on” or “off ” state has been changed (ex. Press S1 S2 or include on/offbutton), it will send Binary Switch Report to the nodes of Group1~3.    Binary Switch ReportON:[Command Class Switch Binary, Switch Binary Report, Value =(255)0xFF]OFF:[Command Class Switch Binary, Switch Binary Report, Value =0(0x00)]2-2 Multi Channel Command Class Version 3PAN06 also support muti channel command class(version 3) , which include BINARY_SWITCH_GET, BINARY_SWITCH_SETYou may control or get report from 3 endpoint of PAN062-2-1 BINARY_SWITCH_GET,You may get the ON/OFF state from every endpoint, when endpoint set to 1 , PAN06 will reply ON(0xFF) either Relay 1 or Relay2 is ON, report OFF (0x00) when both Relay 1 and Relay2  OFF .  If endpoint set to 2 , PAN06 will reply state of Relay1 . If endpoint set to 3 and PAN06 will reply state of Relay2Below is a example show a source endpoint 5 send a get command to PAN06 endpoint 1COMMAND_CLASS_MULTI_CHANNELMULTI_CHANNEL_CMD_ENCAPSource End Point = 0x05 (this is the endpoint of command owner here we assume endpoint is 5,if the owner doesn’t support multi Channel this value will be 0)(Bit Address+Destination End Point = 0x01) (Bit Address =0;Destination End Point range from 1~3)Command Class = 0x25 (Command_Class_Switch_Binary = 0x25)Command =0x02 (Switch_Binary_Get = 0x02)Below is the example show PAN06 report to last commandCOMMAND_CLASS_MULTI_CHANNELMULTI_CHANNEL_CMD_ENCAPSource End Point = 0x01 Since  the endpoint is 1 so PAN06 will reply ON(0xFF) either Relay 1 or Relay2is ON, report OFF (0x00) when both Relay 1 and Relay2  OFF(Bit Address+Destination End Point = 0x05) (Bit Address =0;Destination End Point)Command Class = 0x25 (Command_Class_Switch_Binary = 0x25)5
Command =0x03 (Switch_Binary_Report = 0x03)Parameter 1 = 0xFF (ON=0xFF , OFF=0x00)2-2-2 BINARY_SWITCH_SETBy using BINARY_SWITCH_SET Command of Multi Channel Command Class Encapsulation Command, you can switch both Relay1 and Relay2 ON/OFF by setting endpoint to 1 or switch Relay1 ON/OFF by setting endpoint to 2 or switch Relay2 ON/OFF by setting endpoint to 3The example of the command show that switch off relay1 of PAN06COMMAND_CLASS_MULTI_CHANNELMULTI_CHANNEL_CMD_ENCAPSource End Point = 0x01 (this is the endpoint of command owner here we assume endpoint is 1,if the owner doesn’t support multi Channel thisvalue will be 0)(Bit Address+Destination End Point = 0x02) (Bit Address =0;Destination End Point range1~3)Command Class = 0x25 (Command_Class_Switch_Binary = 0x25)Command =0x01 (Switch_Binary_Set = 0x01)Parameter 1 = 0x00 (ON=0xFF , OFF=0x00)3. Z-Wave’s ConfigurationConfigurationParameterFunction Size(Byte)Value Unit Default Description1 Slected End Point1 1-3 1 1:Relay1 & Relay22:Relay13:Relay22 Edge or Pulse mode or Edge-Toggle mode1 1-3 1 1:Edge mode2:Pulse mode3:Edge-Toggle   mode3-1 Selected EndpointIf Controller not using Multi_Channel command class to access the endpoint ofPAN06, you may configure the endpoint value to react the Basic Command Classor Binary Switch Command Class. 3-1-1 Selected Endpoint 1: Default Selected Endpoint is 1Set command Relay stateBasic Set or Binary_Switch_Set ON Relay1   ON   &6
Relay2 ONBasic Set or Binary_Switch_Set OFF Relay1   OFF   &Relay2 OFFGet command Relay state  Report to command senderBasic_Get or Binary_Switch_Get Relay1   ON   orRelay2 ON ONBasic_Get or Binary_Switch_Get Relay1   OFF   &Relay2 OFFOFF3-1-2 Selected Endpoint 2Similar like Selected Endpoint 1 but only relate to Relay1 and ignore Relay23-1-3 Selected Endpoint 3Similar like Selected Endpoint 1 but only relate to Relay2 and ignore Relay13-2 Edge / Pulse / Edge-Toggle modeManual switch S1 and S2 can set to Edge mode or Pulse mode or Edge-Toggle mode , default value is Edge mode.Edge mode: this mode is suitable for the bi stable wall switch that has indicator point on the switch, and the same position correspond to same state of relay1 and relay2 . if the PAN06 relay change the state because of receiving Z-Wave RF command, it may need two times of change (switch on to off  or  switch off to on) to let relay back to the correspond state.  Pulse mode: this mode is suitable for the toggle type wall switch to swap the state of Relay1 or Relay2Edge-Toggle mode: this mode is suitable for the normal bi-stable switch, every time when change the state of the wall switch will also swap the state of Relay1 or Relay2 4. Command ClassesThe Switch supports Command Classes including…* COMMAND_CLASS_SWITCH_BINARY* COMMAND_CLASS_BASIC* COMMAND_CLASS_MANUFACTURER_SPECIFIC_V2* COMMAND_CLASS_VERSION* COMMAND_CLASS_SWITCH_ALL* COMMAND_CLASS_ASSOCIATION_V1* COMMAND_CLASS_CONFIGURATION* COMMAND_CLASS_MULTI_CHANNEL_V3* COMMAND_CLASS_ALARMTroubleshooting                 Symptom Cause of Failure RecommendationThe Switch not working andLED off1. The Switch is not connect to the Main power2. The Switch break down1. Check power connections2. Don’t open up the Switch and send it for repair.7
The Switch LED illuminating, but cannot control the ON/OFFSwitch of the load attachedCheck if the load connect into the Switch has its own ON/OFF switchSet the ON/OFF switch of the load attached to ONThe Switch LED illuminating, but the Detector cannot controlthe Switch1. Not carry out association2. Same frequency interference1. Carry out association2. Wait for a while to re-tryLED keep flashing continuously, but cannot controlOverload occurs Remove the load attached or check max. load cannot exceed 1500W~1650WSpecificationOperating Voltage 100 ~240VAC24-60V DC ±10%Maximum Load 1500W X2  (220V)  800W X 2 (120V) Range Minimum 30 m in door 100m outdoor  line of sightOperating Temperature 0°C ~ 40°CFrequency Range PAN06-1 868.42 (EU) / PAN06-2 908.42(USA/Canada) / PAN06-3 922.5/923.9/926.3MHz (Taiwan/JP)MHz** Specifications are subject to change and improvement without notice.                                                                                       FCC ID : RHHPAN06 Warning:1.Plug out to disconnect from power supply; Do not plug in line. 2. Do not exceed the max rating Disposal This marking indicates that this product should not be disposed with other household wastes throughout the EU. To prevent possible harm tothe environment or human health from uncontrolled waste disposal, recycle it responsibly to promote the sustainable reuse of material resources. To return your used device, please use the return and collection systems or contact the retailer where the product was purchased. They can take this product for environmental safe recycling.Company of License Holder:Philio Technology CorporationAddress of License Holder:8F.,No.653-2,Zhongzheng Rd., Xinzhuang Dist., New Taipei City 24257,Taiwan(R.O.C)  FCC Interference StatementThis equipment has been tested and found to comply with the limits fora Class B digital device, pursuant to Part 15 of the FCC Rules. Theselimits are designed to provide reasonable protection against harmfulinterference in a residential installation. This equipment generates, usesand can radiate radio frequency energy and, if not installed and usedin accordance with the instructions, may cause harmful interference to8
radio communications. However, there is no guarantee thatinterference will not occur in a particular installation. If this equipmentdoes cause harmful interference to radio or television reception, whichcan be determined by turning the equipment off and on, the user isencouraged to try to correct the interference by one of the followingmeasures:• Reorient or relocate the receiving antenna.• Increase the separation between the equipment and receiver.• Connect the equipment into an outlet on a circuit different fromthat to which the receiver is connected.• Consult the dealer or an experienced radio/TV technician forhelp.This device complies with Part 15 of the FCC Rules. Operation is subjectto the following two conditions:(1) This device may not cause harmful interference, and(2) This device must accept any interference received, includinginterference that may cause undesired operation.FCC Caution: Any changes or modifications not expressly approved bythe party responsible for compliance could void the user's authority tooperate this equipment.This transmitter must not be co-located or operating in conjunctionwith any other antenna or transmitter.9