Philio Technology PAN06 IN Wall Watch User Manual BH002 RF ON OFF CONTROLLER
Philio Technology Corporation IN Wall Watch BH002 RF ON OFF CONTROLLER
(PAN06-2) UserMan
PAN06-1/-2/-3 In Wall Dual relay(1 way) switch module technology can reduce the inrush current caused by the load and let the module work perfectly with many kind of light like incandescent, fluorescent and LED light. This module can also connect to alternative power supply like DC 12V to switch on/off 12V MR-16 light as follow picture. Adding to Z-WaveTM Network In the front casing, there is an on/off button with LED indicator below which is used to toggle switch on and off or carries out inclusion, exclusion, reset or association. When first power is applied, its LED flashes on and off alternately and repeatedly at 2-second intervals. It implies that it has not been assigned a node ID and cannot work with Z-Wave enabled devices. Auto Inclusion The function of auto inclusion will be executed as long as the in wall switch does not have Node ID and just connect the switch to main power. Fig 1. Assembling Note: Auto inclusion timeout is 4 minute during which the node information of This in-wall switch module is a transceiver which is a Z-WaveTM enabled device and is fully compatible explorer frame will be emitted once every 5 seconds. Unlike “inclusion” function as with any Z-WaveTM enabled network. Mini size design let the module can easily hide itself into the wall shown in the table below, the execution of auto inclusion is free from pressing the box and that will be good for the house decoration. On/Off button on the Switch. There are many kind of application by using the module to switch Load On and Off , one main application is the light control. If connect the com port directly to AC Line terminal ,the new smart relay calibration The table below lists an operation summary of basic Z-Wave functions. Please refer Association 1. to the instructions for your Z-WaveTM Certificated Primary Controller to access the Have Z-Wave Controller entered One press one flash association mode. Setup function, and to include/exclude/associate devices Or Pressing Include button of PAN06 three times within 1.5 seconds will Function Description LED Indication No node ID The Z-Wave Controller does not allocate 2-second on, 2-second off enter association mode 2. There are 3 groups for the switch a node ID to the Switch. Inclusion 1. Have Z-Wave Controller entered ※Including a node ID allocated by Z-Wave Controller means inclusion. One press one flash inclusion mode. Excluding a node ID allocated by Z-Wave Controller means exclusion. ※Failed or success in including/excluding the node ID can be viewed from the Z-Wave 2. Pressing Include button of PAN06 three times within 1.5 seconds will Controller. enter inclusion mode. Exclusion 1. 2. Have Z-Wave Controller entered One press one flash Sometimes people are not easy to execute exclusion or inclusion especially when exclusion mode. PAN06 already installed in a wall box. To solve this issue, PAN06 support a special Pressing Include button of PAN06 feature that can use S1 or S2 to execute “exclusion, inclusion, Reset or Association” three times within 1.5 seconds will at the first 3 minutes when first time connect to main power. enter exclusion mode. Reset 1. Node ID has been excluded. 2-second on, 2-second off LED Indication Pressing Include button of PAN06 One press one flash To distinguish what mode the switch is in, view from the LED for identification. three times within 1.5 seconds will 2. 3. enter inclusion mode. State Type LED Indication Within 1 second, press Include Normal Whenever we switch On and off of the PAN06 by S1 S2 or On/Off button of PAN06 again for 5 button or RF command , the LED will lights up 1 second and then seconds until LED is off. off. IDs are excluded. 2-second on, 2-second off No node ID Under normal operation, when the Switch has not been allocated a node ID, the LED flashes on and off alternately at 2-second intervals. By pressing S1 S2 or On/Off button, it will stop flashing temporarily. However, after disconnect and reconnect the Switch, the LED will flash on and off alternately at 2-second intervals. Choosing a Suitable Location 1. Do not locate the Switch facing direct sunlight, humid or dusty place. 1. Put the in wall switch into a wall box and connect the AC power wire L,N to 2. The suitable ambient temperature for the Switch is 0°C~40°C. PAN06 connector L, N. 3. Do not locate the Switch where exists combustible substances or any source of 2. Connect the wall switch to the PAN06 as Fig1 . heat, e.g. fires, radiators, boiler etc. 3. There are 3 mode PAN06 can be configured to match different kind of wall 4. After putting it into use, the body of Switch will become a little bit hot of which switch, please refer to 3-2 Edge / Pulse / Edge-Toggle mode which described phenomenon is normal. in next section of this user manual 4. If Edge-Toggle mode has been set, and the S1 S2 is connect to normal bi-stable Installation switch, every time when change the state of the wall switch will also swap the state of Relay1 or Relay2 Programming 1. Basic Command Class / Binary Switch Command Class The Switch will respond to BASIC and BINARY commands that are part of the ZWave system. 1-1 BASIC_GET / BINARY_SWITCH_GET Since the switch have two relay, the Switch will report its On/Off state to the Controller by setting Configuration parameter 1. Configuration parameter 1=1(default) Report ON either relay 1 ON or relay 2 ON Report OFF when both relay 1 and relay 2 OFF Configuration parameter 1=2 switch ON and OFF of relay 1 Configuration parameter 1=2 Report ON when relay 1 ON Report OFF when relay 1 OFF Configuration parameter 1=3 switch ON and OFF of relay 2 Configuration parameter 1=3 Report ON when relay 2 ON Report OFF when relay 2 OFF Basic Get Command: [Command Class Basic, Basic Get] [Command Class Basic, Basic Set, Value = (255)0xFF]: the load attached to Basic Report Command: the Switch turns on. Report OFF: [Command Class Basic, Basic Report, Value = 0(0x00)] [Command Class Basic, Basic Set, Value = 0(0x00)]: the load attached to Report ON:[Command Class Basic, Basic Report, Value = (255)0xFF] the Switch turns off. [Command Class Switch Binary, Switch Binary Set, Value = (255)0xFF]: Binary Switch Get Command:[Command Class Switch Binary, Switch the load attached to the Switch turns on. Binary Get] [Command Class Switch Binary, Switch Binary Set, Value = 0(0x00)]: the Binary Switch Report Command: load attached to the Switch turns off. Report OFF:[Command Class Switch Binary, Switch Binary Report, Value =0(0x00)] 2. Z-Wave’s Groups (Association Command Class Version 1) Report ON:[Command Class Switch Binary, Switch Binary Report, Value = (255)0xFF] The Switch can be set to send reports to control associated Z-Wave devices. It supports 3 association groups which every group has one node support. Group1~Group3 support SWITCH_BINARY_REPORT. 1-2 BASIC_SET / SWITCH_BINARY_SET Since the switch have two relay, the load attached to the Switch will turn on or off upon receipt of the following commands from a Z-Wave Controller by setting For group 1, the Switch will report ON/OFF status of Relay1 and Relay2 Configuration parameter 1. For group 2, the Switch will report ON/OFF status of Relay1 For group 3, the Switch will report ON/OFF status of Relay2 2-1 Auto report to Grouping 1 ~3(Maximum Node 1) Configuration parameter 1=1(default) switch ON and OFF both relay 1 and relay 2 2-1-1 On/Off Event Report COMMAND_CLASS_MULTI_CHANNEL When “on” or “off ” state has been changed (ex. Press S1 S2 or include on/off MULTI_CHANNEL_CMD_ENCAP button), it will send Binary Switch Report to the nodes of Group1~3. Source End Point = 0x05 (this is the endpoint of command owner here we assume endpoint is 5,if Binary Switch Report the owner doesn’t support multi Channel this value will be 0) ON:[Command Class Switch Binary, Switch Binary Report, Value (Bit Address+Destination End Point = 0x01) (Bit Address =0;Destination End Point =(255)0xFF] range from 1~3) OFF:[Command Class Switch Binary, Switch Binary Report, Value =0(0x00)] Command Class = 0x25 (Command_Class_Switch_Binary = 0x25) Command =0x02 2-2 Multi Channel Command Class Version 3 (Switch_Binary_Get = 0x02) Below is the example show PAN06 report to last command PAN06 also support muti channel command class(version 3) , which include COMMAND_CLASS_MULTI_CHANNEL BINARY_SWITCH_GET, BINARY_SWITCH_SET MULTI_CHANNEL_CMD_ENCAP You may control or get report from 3 endpoint of PAN06 2-2-1 BINARY_SWITCH_GET, Source End Point = 0x01 Since the endpoint is 1 so PAN06 will reply ON(0xFF) either Relay 1 or Relay2 You may get the ON/OFF state from every endpoint, when endpoint set to 1 , PAN06 will reply ON(0xFF) either Relay 1 or Relay2 is ON, report OFF (0x00) is ON, report OFF (0x00) when both when both Relay 1 and Relay2 OFF . If endpoint set to 2 , PAN06 will reply Relay 1 and Relay2 OFF state of Relay1 . If endpoint set to 3 and PAN06 will reply state of Relay2 (Bit Address+Destination End Point = 0x05) (Bit Address =0;Destination End Point) Below is a example show a source endpoint 5 send a get command to PAN06 endpoint 1 Command Class = 0x25 (Command_Class_Switch_Binary = 0x25) Command =0x03 (Switch_Binary_Report = 0x03) 3. Z-Wave’s Configuration Parameter 1 = 0xFF (ON=0xFF , OFF=0x00) Configuration 2-2-2 BINARY_SWITCH_SET Function Parameter By using BINARY_SWITCH_SET Command of Multi Channel Command Class Encapsulation Command, you can switch both Relay1 and Relay2 ON/OFF by Size Value Unit Default Description 1:Relay1 & (Byte) Slected 1-3 End Point setting endpoint to 1 or switch Relay1 ON/OFF by setting endpoint to 2 or switch Relay2 2:Relay1 Relay2 ON/OFF by setting endpoint to 3 3:Relay2 The example of the command show that switch off relay1 of PAN06 Edge or 1-3 Pulse COMMAND_CLASS_MULTI_CHANNEL 2:Pulse mode mode or MULTI_CHANNEL_CMD_ENCAP Source End Point = 0x01 3:Edge-Toggle mode Edge(this is the endpoint of command owner Toggle here we assume endpoint is 1,if the mode 1:Edge mode owner doesn’t support multi Channel this value will be 0) 3-1 Selected Endpoint (Bit Address+Destination End Point = 0x02) (Bit Address =0;Destination End Point If Controller not using Multi_Channel command class to access the endpoint of range1~3) PAN06, you may configure the endpoint value to react the Basic Command Class Command Class = 0x25 (Command_Class_Switch_Binary = or Binary Switch Command Class. 0x25) Command =0x01 Parameter 1 = 0x00 3-1-1 Selected Endpoint 1: Default Selected Endpoint is 1 (Switch_Binary_Set = 0x01) (ON=0xFF , OFF=0x00) Set command Relay state Basic Set or Binary_Switch_Set ON Relay1 ON Edge-Toggle mode: this mode is suitable for the normal bi-stable switch, every time Relay2 ON Basic Set or Binary_Switch_Set OFF Relay1 OFF when change the state of the wall switch will also swap the state of Relay1 or Relay2 Relay2 OFF Get command Relay state Basic_Get or Binary_Switch_Get Relay1 ON 4. Command Classes Report to command sender or ON The Switch supports Command Classes including… Relay2 ON Basic_Get or Binary_Switch_Get * COMMAND_CLASS_SWITCH_BINARY Relay1 OFF & OFF * COMMAND_CLASS_BASIC Relay2 OFF * COMMAND_CLASS_MANUFACTURER_SPECIFIC_V2 3-1-2 Selected Endpoint 2 * COMMAND_CLASS_VERSION Similar like Selected Endpoint 1 but only relate to Relay1 and ignore Relay2 * COMMAND_CLASS_SWITCH_ALL 3-1-3 Selected Endpoint 3 * COMMAND_CLASS_ASSOCIATION_V1 * COMMAND_CLASS_CONFIGURATION Similar like Selected Endpoint 1 but only relate to Relay2 and ignore Relay1 * COMMAND_CLASS_MULTI_CHANNEL_V3 3-2 Edge / Pulse / Edge-Toggle mode * COMMAND_CLASS_ALARM Manual switch S1 and S2 can set to Edge mode or Pulse mode or Edge-Toggle mode , default value is Edge mode. Edge mode: this mode is suitable for the bi stable wall switch that has indicator point Troubleshooting on the switch, and the same position correspond to same state of relay1 and relay2 . if the PAN06 relay change the state because of receiving Z-Wave RF command, it may need two times of change (switch on to off or switch off to on) to let relay back Symptom to the correspond state. The Switch not working and 1. The Switch is not 1. Check power connections LED off 2. Don’t open up the Switch and Pulse mode: this mode is suitable for the toggle type wall switch to swap the state of Cause of Failure connect to the Main power Relay1 or Relay2 2. The Switch break down Recommendation send it for repair. The Switch LED Check if the load connect Set the ON/OFF switch of the load illuminating, but cannot into the Switch has its control the ON/OFF own ON/OFF switch attached to ON Warning: 1.Plug out to disconnect from power supply; Do not plug in line. Switch of the load attached The Switch LED 2. Do not exceed the max rating 1. Not carry out illuminating, but the association Detector cannot control 1. Carry out association Disposal 2. Wait for a while to re-try This marking indicates that this product should not be disposed with 2. Same frequency the Switch other household wastes throughout the EU. To prevent possible harm to interference Remove the load attached or check the environment or human health from uncontrolled waste disposal, continuously, but cannot max. load cannot exceed recycle it responsibly to promote the sustainable reuse of material control 1500W~1650W resources. To return your used device, please use the return and LED keep flashing Overload occurs collection systems or contact the retailer where the product was purchased. They can take this product for environmental safe recycling. Specification Operating Voltage 100 ~240VAC Company of License Holder:Philio Technology Corporation 24-60V DC ±10% Address of License Holder:8F.,No.653-2,Zhongzheng Rd., Xinzhuang Dist., New Taipei City 24257,Taiwan(R.O.C) Maximum Load 1500W X2 (220V) 800W X 2 (120V) Range Minimum 30 m in door 100m outdoor line of sight Operating Temperature 0°C ~ 40°C FCC Interference Statement Frequency Range PAN06-1 868.42 (EU) / PAN06-2 908.42(USA/Canada) / PAN06-3 This equipment has been tested and found to comply with the limits for 922.5/923.9/926.3MHz (Taiwan/JP)MHz a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses ** Specifications are subject to change and improvement without notice. and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to FCC ID : RHHPAN06 radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one of the following measures: • Reorient or relocate the receiving antenna. • Increase the separation between the equipment and receiver. • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. • Consult the dealer or an experienced radio/TV technician for help. This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) This device must accept any interference received, including interference that may cause undesired operation. FCC Caution: Any changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate this equipment. This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter.
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.4 Linearized : No Page Count : 9 Language : zh-TW Title : BH002 RF ON/OFF CONTROLLER Author : . Creator : Writer Producer : LibreOffice 4.0 Create Date : 2013:05:30 16:00:23+08:00EXIF Metadata provided by EXIF.tools