Philips Group Innovation Research DTI2 DTI-2 User Manual for DTI 2

Philips Group Innovation, Research DTI-2 for DTI 2

UserManual.pdf

Download: Philips Group Innovation Research DTI2 DTI-2 User Manual for DTI 2
Mirror Download [FCC.gov]Philips Group Innovation Research DTI2 DTI-2 User Manual for DTI 2
Document ID2206443
Application IDug4l/cMUO0NFG5TwpL6C+Q==
Document DescriptionUserManual.pdf
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize45.45kB (568109 bits)
Date Submitted2014-03-05 00:00:00
Date Available2014-03-05 00:00:00
Creation Date2013-11-26 12:53:23
Producing SoftwareMicrosoft® Word 2010
Document Lastmod2014-01-09 16:03:22
Document TitleUser manual for DTI-2
Document CreatorMicrosoft® Word 2010
Document Author: Martin Ouwerkerk

© 2013 Koninklijke Philips Electronics N.V.
All rights reserved.
DTI_2_UM_V2.0 8122 357 24302
DTI-2
__________________________
__________________________
EN User manual
NL Gebruiksaanwijzing
DE Benutzerhandbuch
FR Mode d’emploi
SV Användarhandbok
SR Korisničko uputstvo
EN
Contents
Important
Important Safety Instructions
Notice
Recycling
Your Discreet Tension Indicator
Introduction
What’s in the box
Overview of the device
User interface
Intended use
How to use the device
Wearing instructions
Switching the device on/off
Bluetooth wireless data transmission
Event marker
Status button
Time synchronization
Battery charging
Data readout
Data format and visualization
10
10
10
Product information
12
EN
1 Important
Important Safety Instructions
Read these instructions.
Keep these instructions.
Heed all warnings.
Follow all instructions.
Do not use this device under shower/in bath.
Clean only with dry or moist cloth.
Only use attachments/accessories specified by the manufacturer.
Refer all servicing to qualified service personnel. Servicing is
required when the device has been damaged in any way, such as
when the device has been exposed to water, does not operate
normally, or has been dropped
Battery usage CAUTION – To prevent battery leakage which may
result in bodily injury, property damage, or damage to the unit, the
batteries (battery pack or batteries installed) shall not be exposed
to excessive heat such as sunshine, fire or the like.
Notice
Any changes or modifications made to this device that are not
expressively approved by Philips may void the user’s authority to operate
the equipment.
This is a class 1 device.
Hereby Philips Research declares that this skin conductance wristband is
in compliance with the essential requirements and other relevant
provisions of Directive 1999/5/EC.
0682
This product complies with the radio interference requirements of the
European Community.
EN
This device complies with Part 15 of the FCC Rules.
Operation is subject to the following two conditions:
(1)
this device my not cause harmful interference, and
(2)
this device must accept any interference received, including
interference that may cause undesired operation.
NOTICE:
Changes or modifications made to this equipment not expressly
approved by PHILIPS may void the FCC authorization to operate this
equipment.
NOTE: This equipment has been tested and found to comply with the
limits for a Class B digital device, pursuant to Part 15 of the FCC Rules.
These limits are designed to provide reasonable protection against
harmful interference in a residential installation.
This equipment
generates, uses and can radiate radio frequency energy and, if not
installed and used in accordance with the instructions, may cause
harmful interference to radio communications. However, there is no
guarantee that interference will not occur in a particular installation. If
this equipment does cause harmful interference to radio or television
reception, which can be determined by turning the equipment off and on,
the user is encouraged to try to correct the interference by one or more of
the following measures:
 Reorient or relocate the receiving antenna.
 Increase the separation between the equipment and receiver.
 Connect the equipment into an outlet on a circuit different from that
to which the receiver is connected.
 Consult the dealer or an experienced radio/TV technician for help.
Radiofrequency radiation exposure Information:
The radiated output power of the device is far below the FCC radio
frequency exposure limits. Nevertheless, the device shall be used in such
a manner that the potential for human contact during normal operation is
minimized.
EN
Recycling
Your product is designed and manufactured with high quality materials
and components, which can be recycled and reused.
When you see the crossed-out wheel bin symbol attached to a product, it
means the product is covered by the European Directive 2002/96/EC.
Never dispose of your product with other household waste. Please inform
yourself about the local rules on the separate collection of electrical and
electronic products. The correct disposal of your old product helps
prevent potentially negative consequences on the environment and
human health.
Your product contains batteries covered by the European Directive
2006/66/EC, which cannot be disposed of with normal household waste.
Please inform yourself about the local rules on separate collection of
batteries. The correct disposal of batteries helps prevent potentially
negative consequences on the environment and human health.
Always bring your product to a professional to remove the built-in battery.
2 Your Discreet Tension Indicator
Congratulations on your purchase and welcome to Philips!
Introduction
The Discreet Tension Indicator (DTI-2) is a wrist worn sensor device for
daily life use.
EN
What’s in the box
Check and identify the contents of your package:
1 x Sensor wristband
1 x USB cable
1 x USB charger
1 x quick start guide
Overview of the device
User interface
Fastening hinge – the USB connector is behind it
Skin conductance electrode
Wrist strap
Skin temperature sensor
Personal fit segments
XXS 5 segments
XS 6 segments
7 segments
8 segments
9 segments
XL 10 segments
XXL 11 segments
EN
User interface
LED arrays
Bluetooth button
On/off button
Bluetooth LED
Status button
Event marker button
Two 8-piece LED arrays are available for communications to the wearer.
The arrays lit when the device switches on or off. When the status button
is switched the skin conductance level and skin temperature are visible
for 10 seconds. When the Bluetooth active a blue LED is visible above
the Status button.
3 Intended use
The device is to be used to monitor at the left or right wrist of humans:
the skin conductance, skin temperature, ambient temperature, ambient
light level, and 3-dimensional acceleration. The sensor data can be
streamed live to a receiving station via a Bluetooth wireless link. The
device is to not to be used as a medical device. Hence no diagnosis or
treatment of a medical illness can or may be performed based on the
data obtained by this device.
EN
4 How to use the device
Wearing instructions
The device is worn on the left or right wrist. If a wristwatch is worn, the
DTI-2 should be worn on the other wrist. The position should as close to
the hand as possible without discomfort or hindering any hand postures.
The strap closure is at the side of the thumb. The DTI-2 is fixed to the
wrist with a flexible strap. Please pay attention to the level of tightening.
The wrist band should be fixed to the wrist, i.e. not dangling loose. The
wrist band should however be comfortable to wear and not strapped too
tight. Optimal is the loosest strap position without dangling.
Place the rubber strap on the underside of the wrist, such that the skin
conductance electrodes contact a desired area of the skin:
recommended is to center the electrode furthest from the thumb and
wrap the strap towards the electronics module.
Recommended position of the wristband sensor skin conductance
electrode for best results.
Switching the device on/off
The unit is switched on by pressing the on/off button continuously for
more than 4 seconds. When activated the device flashes the LED
arrays to indicate readiness.
The device goes into sleep mode by pressing continuously for more
than 4 seconds on the on/off button when the device is in active mode.
When this happens the rows of LEDs light up briefly.
EN
Bluetooth wireless data transmission
During use the Bluetooth wireless data transmission can be started by
pressing the top right button, which is the Bluetooth activation button. A
Blue LED situated top right starts blinking and stays lit during Bluetooth
listening. For first time use the device needs to be linked to the receiving
device. The pairing code is 0000. On the embedded microSD card a
program called DTI-2 Streaming Data Viewer is available, which can
visualize the transmitted data on a Windows computer. Connect the
DTI-2 to the computer with the USB cable to mount the microSD card as
a directory, and run setup to install the program.
Event marker
During use events can be marked into the database using the lower left
button, which is the Event marker button. Both rows of LEDs light up to
indicate that an event marker has been recorded into the database.
Status button
During use the current skin conductance and skin temperature status can
be visualized by means of the two LED arrays using lower right button,
which is the status button. The left array shows the skin temperature: all
LEDs on means 38 degrees Celsius. The decrement is 1 degree per
LED, so one LED lit means 31 degrees Celsius. The right array shows
the skin conductance normalized to the average of the last minute
(3LEDs on). Per increment of 1%, a LED switches on or off. This allows a
visualization of the recent skin conductance changes.
Time synchronization
The DTI-2 can keep track of time and date. In active mode and in sleep
mode the internal real time clock takes care of this. All measured sensor
data is time stamped and stored in a data file on the microSD card.
Before active use of the DTI-2 it needs to be synchronized with a
Windows 7 PC to ensure accurate time stamping.
Two methods are available for synchronization:
1) Connect the DTI-2 to a PC the USB cable. In the DTI2-0XXX drive
(XXX being the serial number of the DTI-2) double click
CreateDTITIME.bat to create a file named DTITime.txt. Unhook the
device immediately after writing and switch it on. The creation
time/date of the DTITime.txt file is used as synchronization time.
CAUTION: the latency between the creation time/date of the
DTITime.txt file and switching on the DTI-2 is not taken into
10
EN
account, which causes an error in the synchronization of at least
several seconds.
2) Establish a Bluetooth link with the DTI-2 and start up the
DTI-2_BT_StreamingDataViewer program that can be found on the
internal data storage of the DTI-2. After opening the communication
in this program synchronization will take place automatically.
Battery charging
Battery recharging is done with the supplied USB charger via the USB
cable, which needs to be inserted into the USB connector that can be
found behind the fastening hinge. A red LED placed close to the USB
connector indicates active charging. It takes about 2 hours to charge the
device from empty to full. The red LED may not switch off when a full
charge state is realized. The sure way to check whether the battery has a
full charge is to unplug the USB cable, and to plug it in again: when the
red LED stays out the battery is fully charged.
Data Readout
1) Connect it to a Windows7/Vista/XP™ PC with the USB cable. A blue
LED close to the USB connector indicates a functional USB
connection.
2) The device mounts as ‘’Device with Removable Storage’’ on your PC.
Open the explorer and click the drive associated with the DTI-2
(should this fail to happen unplug the USB cable and reconnect it).
When asked to scan and fix the device, please comply, and tick both
check disk options. After the scan the DTI-2 drive mounts normally.
3) Copy the data files to a location of your choice on your own computer.
4) Undock the device after this operation
Data format and data visualization
The measured data is stored in a binary file named DTISamples0XXX.dti,
where XXX is the serial number of the device. This file can be converted
into a text file with the DTI-2_SampleFileParser-P program which is
present on the DTI-2 data storage disk. Run this program, select the .dti
file, and choose Convert DTI Sample File. This will generate a text file
with all data in lines with this format:
yyyymmddHHMMSSmmm|NNNN|ev|ttttt|sksks|xxxxx|yyyyy|zzzzz|vb|etete|eieie|rrrrr
A minus sign may precede the accelerometer data xxxxx, yyyyy or zzzzz. The
description of the line coding is given in the next Table.
EN
11
Layout code
yyyy
mm
dd
HH
MM
SS
mmm
NNNN
ev
ttttt
sksks
xxxxx|yyyyy|zzzzz
vb
etete
eieie
rrrrr
snr
Description
Year
Month
Day
Hours
Minutes
Seconds
milli seconds
Serial number
Event
Skin Temperature
Skin Conductance
3D acceleration (x,y,z)
Battery voltage
Ambient temperature
Ambient light level
Skin conductance ADC
Dataset number
width
15
Format
201x
01-12
01-31
00-24
00-60
00-60
000-999
0001-9999
1=button; 2=detected
100x oC
nano Siemens
counts (16384 = 1 g)
10x Voltage
100x oC
Counts
16bit raw ADC output
The visualization can be done using the DTI-2 Data Viewer program.
This can be installed from the integrated data storage of the DTI-2.
Connect the device to a computer with a USB cable.The DTI-2 mounts
as ‘’Device with Removable Storage’’ on your computer. Open the
explorer and click the drive associated with the DTI-2 (should this fail to
happen unplug the USB cable and reconnect it). In the directory
DTI-2_DTIfileDataViewerV1.0 Installer a program called setup.exe is
located, which installs the data viewer program onto your (Microsoft
Windows7/Vista/XP™) computer. A screenshot is shown below.
12
EN
5 Product Information
Dimensions
39.5 x 12 x 63.5 mm
Weight
Power supply
40 g
Battery life
Operating temperature range
USB
Skin conductance sensor
Charger: Input: AC 100-240V, 50/60 Hz
Output: DC 5V 0.5A
Battery: 3.7V 400mAh Lithium Polymer
30 hours without wireless data streaming
12 hours with wireless data streaming
-20 – 50oC (-4 – 122oF)
2.0
Wireless connection
0.01-65.5 micro Siemens range
0.001 micro Siemens sensitivity
Silver coated Eyelet A3822C2 Micron electrodes
-20 – 85oC range
0.02oC sensitivity
100o field of view
-40 – 125oC range
0.5 – 2oC accuracy (best at 40oC)
24.4 counts/µW/cm2 responsivity at 640nm
for the VIS-IR diode
6.9 counts/µW/cm2 responsivity at 940 nm for
the IR diode
±2g range
0.001 g per bit sensitivity
Bluetooth 2.1
Data storage
2GB microSD card
Sampling frequency
2-25 Hz firmware dependent
Skin temperature sensor
Ambient temperature sensor
Ambient light sensor
3D accelerometer
EN
13

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.5
Linearized                      : Yes
Author                          : Martin Ouwerkerk
Create Date                     : 2013:11:26 12:53:23+01:00
Keywords                        : Skin, Conductance
Modify Date                     : 2014:01:09 16:03:22+01:00
Subject                         : DTI-2
Language                        : en-US
Tagged PDF                      : Yes
XMP Toolkit                     : Adobe XMP Core 4.2.1-c043 52.372728, 2009/01/18-15:08:04
Format                          : application/pdf
Creator                         : Martin Ouwerkerk
Description                     : DTI-2
Title                           : User manual for DTI-2
Creator Tool                    : Microsoft® Word 2010
Metadata Date                   : 2014:01:09 16:03:22+01:00
Producer                        : Microsoft® Word 2010
Document ID                     : uuid:8d089623-7455-4576-8d24-c9ffc7b31e12
Instance ID                     : uuid:a320bb95-acb7-49bb-b726-572c12589c8d
Page Count                      : 13
EXIF Metadata provided by EXIF.tools
FCC ID Filing: 2AALC-DTI2

Navigation menu