Phychips PRM90U10A UHF RFID READER HYBRID MODULE User Manual User s Menuals x
Phychips Inc. UHF RFID READER HYBRID MODULE User s Menuals x
Phychips >
USERS MANUAL
USER’S MANUAL December 2010 PRM90U10A Specification- Preliminary Version Contents Overview & block composition diagram ................................................... 3 Pin Description ............................................................................................ 4 Operation method........................................................................................ 6 Specification ……………………………………………………………………..12 9 December 2010 2 of 13 PRM90U10A Specification- Preliminary Version Overview & Block Composition Diagram 1.1 Overview The PRM90U10A is a UHF RFID Reader hybrid module which integrates high performance UHF RFID reader chipset, VC-TCXO, Low Drop Regulator, Balun, Coupler, Saw filter, Power amp, Isolator and low pass filter. UHF RFID reader chipset uses PR9000 of PHYCHIPS which integrates 900MHz radio, baseband processor, industry standard enhanced 8052 MCU, memory (64k Flash & 16k SRAM) and many other features. This module fully compliant with ISO18000-6C/EPC Global Gen II reader protocol and provide all functions of PR9000. Also reduce size, cost and power consumption. 1.2 Block Domposition Diagram DC 3.6V/500mA PRM90K10x SHDNb LDO 19.2MHz TCXO GPIO PR9000 RF I/O BALUN COUPLER AMP BALUN SAW LPF Figure 1 Block Composition Diagram 9 December 2010 3 of 13 PRM90U10A Specification- Preliminary Version Pin Description 29 27 2523 21 19 1715 13 11 9 7 5 3 1 30 28 2624 22 20 1816 14 12 10 8 6 4 2 35 34 33 32 31 30 29 28 27 26 25 24 23 22 21 20 19 18 17 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 29 27 2523 21 19 1715 13 11 9 7 5 3 1 30 28 2624 22 20 1816 14 12 10 8 6 4 2 Figure 2 Pin Description 2.1 J1 Pin Description No. Pin Name Description 10 11 12 13 14 15 16 17 18 VDD_3.6V VDD_3.6V VDD_3.6V VDD_3.6V GND GND GND GND NC NC NC NC GND GND NC NC GND GND 3.6 V DC Power for SOC(Max. 1A) 3.6 V DC Power for SOC(Max. 1A) 3.6 V DC Power for SOC(Max. 1A) 3.6 V DC Power for SOC(Max. 1A) Ground Ground Ground Ground Reserved, Not Ground Reserved, Not Ground Reserved, Not Ground Reserved, Not Ground Ground Ground Reserved, Not Ground Reserved, Not Ground Ground Ground 9 December 2010 4 of 13 PRM90U10A Specification- Preliminary Version 19 20 P2.2 NC 21 MDS_SCL 22 MDS_SDA 23 24 25 26 27 28 GND RESETb P0.1 P0.0 NC P0.2 29 P0.5 30 P0.4 Quasi-bidirectional I/O port Reserved, Not Ground I/O for ISP. The pull-up resistor is always switched on. This port is quasibidirectional I/O for ISP. The pull-up resistor is always switched on. This port is quasibidirectional Ground External Reset for SOC Quasi-bidirectional I/O port or Serial Port 0 Output Quasi-bidirectional I/O port or Serial Port 0 Input Reserved, Not Ground Quasi-bidirectional I/O port or External Interrupt Input 0 Quasi-bidirectional I/O port or Timer 1 External Input or SPI Master Output Slave Input Quasi-bidirectional I/O port or Timer 0 External Input or SPI Master Input Slave Output 2.2 J2 Pin Description No. Pin Name Description 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 NC NC GND GND NC NC GND GND TXD1 RXD1 GND GND P1.7 P1.6 P1.5 P1.4 P1.3 P1.2 P1.1 P1.0 P0.7 P0.6 NC NC NC NC GND GND 29 SHDNb Reserved, Not Ground Reserved, Not Ground Ground Ground Reserved, Not Ground Reserved, Not Ground Ground Ground Quasi-bidirectional I/O port or Serial Port 1 Output Quasi-bidirectional I/O port or Serial Port 1 Input Ground Ground Quasi-bidirectional I/O port or External Interrupt 5 (Negative Edge) Quasi-bidirectional I/O port or External Interrupt 4 (Positive Edge) Quasi-bidirectional I/O port or External Interrupt 3 (Negative Edge) Quasi-bidirectional I/O port or External Interrupt 2 (Positive Edge) Quasi-bidirectional I/O port or I2C SCL Quasi-bidirectional I/O port or I2C SDA Quasi-bidirectional I/O port or Timer/ Counter 2 Capture/Reload Trigger Quasi-bidirectional I/O port or External Input for Timer/Counter 2 Quasi-bidirectional I/O port or SPI Slave Select Bar Quasi-bidirectional I/O port or SPI SCK Reserved, Not Ground Reserved, Not Ground Reserved, Not Ground Reserved, Not Ground Ground Ground Module Enable/Disable Enable : Open Disable : Ground 9 December 2010 5 of 13 PRM90U10A Specification- Preliminary Version 30 Module Enable/Disable Enable : Open Disable : Ground SHDNb 2.3 S1 Pin Description(RF I/O) Operation method DC 3.6V /150mA 10uF 0.1uF 1nF 10 11 UART 12 13 TXD 14 RXD NC NC 15 16 P0.7 P0.5 P1.0 P0.4 P1.1 P0.2 P1.2 P0.1 P1.3 P0.0 P1.4 RESET P1.5 PRM90U10A MDS_SDA 35 34 33 32 31 30 29 ISP 28 26 MDS_SCL P1.7 P2.2 25 GND SHDN 24 RXD1 GND 23 TXD1 GND 22 NC NC RESET MDS_SDA MDS_SCK VDD GND 27 P1.6 GND P0.6 RFIO GND GND VDDPA_36 21 VDDPA_36 20 OPEN : NORMAL CLOSE : SHUT DOWN DC 3.6V /350mA 1nF 0.1uF10uF100uF 19 VDD_36 17 GND 18 ANT Figure 3 Application Circuit 3.1 Power Supply PRM90U10A should be supplied by 2 kinds of 3.6 volts DC power; VDD_36(Pin 1) and VDDPA_36(Pin 20, 21). VDD_36 is for operating of PR9000 RFID reader chipset which current consumption is about 150mA. VDDPA_36 is for operating of power amp which current consumption is 350mA typically. Additionally, decoupling capacitors should be placed as close as possible these pins. The decoupling capacitors should be placed in the same layer as the module, to avoid any additional parasitic inductance caused by vias. 3.2 Hardware Mode Control PRM90U10A provides normal mode and shut down mode. The mode can control by SHDNb(Pin 24). Normal mode should be controlled by SHDN pin to open which can activate the module. Otherwise, If SHDNb pin contact to ground, supplied power of the module is shut down internally. In shut down mode, all GPIO ports and UART ports should not input any signal and positive voltage. 3.3 UART The serial interface assigned to two pins. RXD1(Pin 13) is for receiving command from host and TXD1(Pin 14) is for transmitting response to host. Pin connection is shown as below figure. 9 December 2010 6 of 13 PRM90U10A Specification- Preliminary Version Figure 4 Connecting to host MCU RS232C transceiver is required for interfacing to PC and diagram connection is shown as below figure. PRM90U10A RS232C Tranceiver GND RXD1 TXD1 12 13 14 PC GND GND GND RXOUT RXIN TXD TXOUT RXD TXIN Figure 5 Connecting to RS232 transceiver Following configuration is used for interfacing to USB transceiver. Figure 6 Connecting to USB transceiver 3.4 ISP For firmware downloading in PRM90U10A should be used GenICE3000 by CORERIVER(manufacturer), which downloading speed is faster than UART. Code memory(62kB) and EEPROM(2kB) can be programmed using EJTAG in target. Following configuration is used for downloading to GenICE3000. Figure 7 Connecting to GenICE3000 for firmware downloading 9 December 2010 7 of 13 PRM90U10A Specification- Preliminary Version 3.5 GPIO PRM90U10A provides 16 bi-directional I/O ports. All ports can be configured in two different modes: opendrain (by default) and push-pull which has 3.3V input and 3.3V output. 3.6 RF In/Out RF I/O(Pin 20) is optimized at 50 ohms impedance. 3.7 Using GUI The GUI is for the user to be able to quickly get started working with PRM90U10A RFID reader. To run the GUI, click the Windows start button, Program menu, Phychips, PR9000 SDK. After start-up, a window will be opened as shown below. Figure 8 Demo GUI 9 December 2010 8 of 13 PRM90U10A Specification- Preliminary Version 3.7.1 Serial Port Control Serial port is controlled by below menu. To open serial port, click Open menu. To close serial port, click Close menu. 3.7.1.1 Serial Port Configurations Port number is selectable from COM1 upto COM9. (Depending on your Windows system settings) Baud Rate should be set 19200 bps. Figure 9 Serial Port Settings 3.7.1.2 Reader Connection Status Below status bar shows the reader connection status. Figure 10 Reader Connection Statuses If PC is successively connected to reader after clicking open button, status bar would be updated as shown below. 9 December 2010 9 of 13 PRM90U10A Specification- Preliminary Version 3.7.2 Hardware Control To control hardware, click ‘H/W Control Tab.’ 3.7.2.1 Band setting To select operating band, band setting should be required. Select band in combo box and click Set button to set operating band in group box ‘Basic settings.’ 3.7.2.2 Power Class setting Some countries classified channel numbers according to the power class. Select the power class and click Set button. 3.7.2.3 Output Power setting To set PR9000 output power, select the PR9000 Tx Power combo box and click Set button. 3.7.2.4 CW (Continuous Wave) setting These buttons are used for hardware debugging purpose only. To turn CW on, click Turn Tx CW on button. To turn CW off, click Turn Tx CW off button. 3.7.3 Procedures for Tags Inventory Operation To read UHF RFID tags with PR9000 SDK software, follow sequence as described below. Configure your serial port settings. Open serial port. Then, PR9000 SDK software will try connecting to PR9000. Select operation band and click ‘Set’ button. Click ‘Tag Information’ tab. 9 December 2010 10 of 13 PRM90U10A Specification- Preliminary Version Figure 11 Procedures for tag inventory operation 9 December 2010 11 of 13 PRM90U10A Specification- Preliminary Version Click ‘Read multiple’ button to start reading RFID tags. Figure 12 Procedures for tag inventory operation Specification max 902.75 927.25 Item Unit Freq. Range MHz Tx Power dBm PR9000 = 4dBm Tx ACPR +/-200kHz dBc PR9000 = 4dBm -20 +/-400kHz dBc PR9000 = 4dBm -50 +/-600kHz dBc PR9000 = 4dBm -60 9 December 2010 Test Condition Specification min Typ. No. Remark 25.5 12 of 13 PRM90U10A Specification- Preliminary Version +/-800kHz dBc PR9000 = 4dBm -65 GPIO = HIGH GPIO = ALL HIGH HIGH GPIO = LOW GPIO = ALL LOW LOW GPIO Impedance Ω 50 DC Power 3.6 OperatingTemperature °C 50 Operating Humidity 60 Consumption Current SHDN IDLE RF I/O mA ACTIVE 16 PR9000 = 4dBm 500 10 Modulation DSB - ASK 11 Size mm 35x45x8 12 Weight 11 550 Cautions Modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment. FCC Information to User This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one of the following measures: • Reorient or relocate the receiving antenna. • Increase the separation between the equipment and receiver. • Connect the equipment into an outlet on a circuit different from that to which the receiver is con-nected. • Consult the dealer or an experienced radio/TV technician for help. FCC Compliance Information : This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation FCC WARNING: This equipment may generate or use radio frequency energy. Changes or modifications to this equipment may cause harmful interference unless the modifications are expressly approved in the instruction manual. The user could lose the authority to operate this equipment if an unauthorized change or modification is made. FCC RF EXPOSURE: The EUT will only be used with a separation of 20 centimeters or greater between the antenna and the body of the user. 9 December 2010 13 of 13
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.6 Linearized : Yes Encryption : Standard V4.4 (128-bit) User Access : Print, Extract, Print high-res Author : MYHOME Create Date : 2010:12:09 16:58:50+09:00 Modify Date : 2010:12:09 17:00:43+09:00 XMP Toolkit : Adobe XMP Core 4.2.1-c043 52.372728, 2009/01/18-15:08:04 Creator Tool : PScript5.dll Version 5.2.2 Metadata Date : 2010:12:09 17:00:43+09:00 Producer : Acrobat Distiller 9.3.2 (Windows) Format : application/pdf Title : Microsoft Word - User's Menuals_영문.docx Creator : MYHOME Document ID : uuid:1b96077f-5881-4481-8329-14576ea3b409 Instance ID : uuid:54d4d401-19e3-47c7-9920-54c2d38fec44 Page Count : 13EXIF Metadata provided by EXIF.tools