Powerwave Technologies 5JS0070 Three Sector 1900 MHz RF Power Amplifier Cabinet User Manual
Powerwave Technologies Inc Three Sector 1900 MHz RF Power Amplifier Cabinet Users Manual
Users Manual
Reference Manual 1. Abbreviations and Acronyms Abbreviation / Acronym Definition { = Two definitions, { same abbreviation/acronym ACLR....................................................... Adjacent Channel Leakage Power Ratio ACP......................................................... Adjacent Channel Power A/D .......................................................... Analog-to-Digital Conversion ADC......................................................... {Analog-to-Digital Converter {Automatic Data Collection AM........................................................... Amplitude Modulation AMPS ...................................................... Advanced Mobile Phone System ANSI........................................................ American National Standards Institute APC......................................................... Automatic Power Control APTT ....................................................... Analog Push To Talk ASG......................................................... Applications Support Group ASIC........................................................ Application Specific Integrated Circuit ATE ......................................................... Automatic (Automated) Test Equipment ATP ......................................................... Acceptance Test Procedure ATTEN .................................................... Attenuator BER......................................................... Beyond Economical Repair BOM ........................................................ Bill Of Materials BPF ......................................................... Band Pass Filter BS ........................................................... Base Station BTS ......................................................... Base Transceiver Station (System) BW .......................................................... BandWidth °C ............................................................ Degrees Celsius CAD......................................................... Computer Aided Design CCA......................................................... {Circuit Card Assembly CCW........................................................ Counter ClockWise CDMA...................................................... Code Division Multiple Access CDPD ...................................................... Cellular Digital Packet Data CTRL....................................................... Control CW .......................................................... {ClockWise {Continuous Wave dB............................................................ deciBels dBc .......................................................... Referenced to a carrier level dBm......................................................... Reference to a specific power level (one milliwatt) dBw ......................................................... Reference to a specific power level (one watt) DIN ......................................................... Deutsches Insitut für Normung eV DLNA....................................................... Duplexer Low Noise Amplifier DPTT....................................................... Digital Push To Talk DQPSK.................................................... Differential Quadrature Phase Shift Keyed DSP......................................................... Digital Signal Processing DUT......................................................... Device Under Test ECD......................................................... Estimated Completion Date ECM ........................................................ Electronic Counter Measure EDGE ...................................................... Enhanced Data for GSM Evolution EEPROM................................................. Electrically-Erasable Programmable Read-Only Memory EIA .......................................................... Electronic Industries Association EMC ........................................................ ElectroMagnetic Compatibility EMI.......................................................... ElectroMagnetic Interference EPROM ................................................... {Electrically Programmable Read-Only Memory {Erasable Programmable Read-Only Memory 044-05156 Rev C ESD......................................................... ElectroStatic Discharge ESG......................................................... Electronic Signal Generator ETDMA.................................................... Extended Time Division Multiple Access ETSI ........................................................ European Telecommunications Standard Institute EUT ......................................................... Equipment Under Test FAR ......................................................... Failure Analysis Report FCC......................................................... Federal Communications Commission FDMA ...................................................... Frequency Division Multiple Access FET ......................................................... Field Effect Transistor FHMA ...................................................... Frequency Hopping Multiple Access FM ........................................................... Frequency Modulation FRU......................................................... Field Replaceable Unit FSK ......................................................... Frequency Shift Key modulation GHz ......................................................... GigaHertz GMSK...................................................... Gaussian Minimum Shift Keying GOLAY.................................................... See GSC GSC ........................................................ Golay Sequential Code GSM ........................................................ Global System for Mobile Communications HPF ......................................................... High Pass Filter HW .......................................................... Hardware Hz............................................................ Hertz IAW ......................................................... In Accordance With IC............................................................. Integrated Circuit IMD.......................................................... InterModulation Distortion IRL........................................................... Input Return Loss IS-54........................................................ Interim Standard 54 for TDMA IS-95........................................................ Interim Standard 95 for CDMA ISDN........................................................ Integrated Services Digital Network ISM.......................................................... Industrial, Scientific and Medical unlicensed frequency bands ISO .......................................................... {International Organization for Standardization {ISOlator kHz .......................................................... KiloHertz LDA ......................................................... Linear Discrete Amplifier (Class A or AB) LGL ......................................................... Lower Guardband Limit LMR......................................................... Land Mobile Radio LMS......................................................... Land Mobile Systems LNA ......................................................... Low Noise Amplifier LO ........................................................... Local Oscillator LPA ......................................................... Linear Power Amplifier LPF.......................................................... Low Pass Filter LSL.......................................................... Lower Specification Limit LVD ......................................................... Low Voltage Disconnect MC........................................................... MultiChannel MCA ........................................................ MultiChannel Amplifier MCPA...................................................... {MultiCarrier Power Amplifier {MultiChannel Power Amplifier MCR ........................................................ MultiChannel Rack MFRM ..................................................... {Multiple Frequency Radio Mobile {Multifunction Frequency Radio Modulation MHz......................................................... MegaHertz MSO ........................................................ Master Switch Office MTBF ...................................................... Mean Time Between Failures MTSO...................................................... Master Telephone Switch Office MU........................................................... Measurement Uncertainty 044-05156 Rev C M&TE ...................................................... Measuring and Test Equipment NAMPS ................................................... Narrow Analog Mobile Phone System NIOSH..................................................... National Institute for Occupational Safety and Health NIST ........................................................ National Institute for Standards and Technology NMT ........................................................ Nordic Mobile Telephone NVM ........................................................ NonVolatile Memory OEM ........................................................ Original Equipment Manufacturer OFDM...................................................... Orthogonal Frequency Division Multiplexing OMS ........................................................ Operational Method Sheet OOB ........................................................ Out Of Box O/P .......................................................... Output OPAF ...................................................... Outdoor Power Amplifier Frame OSHA ...................................................... Occupational Safety and Health Administration PA ........................................................... Power Amplifier PAF ......................................................... Powerwave Amplifier Frame PAR......................................................... Peak to Average Ration PCB......................................................... Printed Circuit Board PCMCIA .................................................. Personal Computer Memory Card International Association PCN......................................................... Personal Communications Network PCS......................................................... {Personal Communications Services {Personal Communication System(s) PDA......................................................... Personal Digital Assistant PEP ......................................................... Peak Envelope Power PF............................................................ PicoFarads PHS......................................................... Personal Handyphone System – Japan PLC ......................................................... Product Life Cycle PLL.......................................................... Phase Locked Loop PM........................................................... {Phase Modulation {Preventive Maintenance PMR ........................................................ Peak to Minimum Ratio PO ........................................................... Purchase Order PPM ........................................................ Parts Per Million PSC......................................................... {PCS Single Channel ................................................................ {Product Serialization Code PSTN....................................................... Public Switched Telephone Network PTI........................................................... Powerwave Technologies, Inc. PTT ......................................................... Push To Talk PWAV...................................................... PowerWAVe QA ........................................................... Quality Assurance QAM ........................................................ Quadrature Amplitude Modulation RBW........................................................ Resolution BandWidth RF ........................................................... Radio Frequency RFI .......................................................... Radio Frequency Interference RFQ......................................................... Request For Quotation RFS ......................................................... RF Solutions RFSU ...................................................... RF Switching Unit RGO ........................................................ Return Goods Order RH ........................................................... Relative Humidity RL............................................................ Return Loss RMA ........................................................ {Rack-Mounted Amplifier {Return Material Authorization RMP ........................................................ Reliability Monitoring Plan (Procedure) RMS ........................................................ Root Mean Square RSS......................................................... Root Sum Square Rx............................................................ Receive, Receiver 044-05156 Rev C SCHPA.................................................... Single-Channel High Power Amplifier SCPA ...................................................... Single Channel Power Amplifier SIM.......................................................... System Interface Module SMA ........................................................ SubMiniature Type A (coaxial connector) SMT......................................................... Surface Mount Technology SN ........................................................... Serial Number SO ........................................................... System Outage SOE......................................................... Sequence of Events SW .......................................................... SoftWare TBC ......................................................... To Be Confirmed TBD ......................................................... To Be Determined (To Be Defined) TCXO ...................................................... Temperature Controlled crystal Oscillator TD ........................................................... {Temperature Drift ................................................................ {Temporary Deviation TDMA ...................................................... Time Division Multiple Access TRU......................................................... Transmit Receive Unit TRX ......................................................... Transceiver (Transmit / Receiver) Unit Tx ............................................................ Transmit, Transmitter UAI .......................................................... Use As Is UART ...................................................... Universal Asynchronous Receiver Transmitter UCL ......................................................... Upper Control Limit UCLR ...................................................... Upper Control Limit for Range UGL......................................................... Upper Guardband Limit UL............................................................ Underwriters Laboratories UMTS ...................................................... Universal Mobile Telecommunications System UNL ......................................................... Unit Nominal Level URG ........................................................ Unit Reference Gain USL ......................................................... Upper Specification Limit UUT......................................................... Unit Under Test VADJ ....................................................... Voltage ADJust (signal name frequently found on schematic or block diagrams) VBW ........................................................ Video BandWidth VCO ........................................................ Voltage Controlled Oscillator VFWD...................................................... Voltage ForWarD (signal name frequently found on schematic or block diagrams) VREFL..................................................... Voltage REFLected (signal name frequently found on schematic or block diagrams) VSWR ..................................................... Voltage Standing Wave Ratio VVA ......................................................... Voltage Variable Attenuator WCDMA .................................................. Wideband Code Division Multiple Access XMT......................................................... Transmit XMTR ...................................................... Transmitter 044-05156 Rev C 2. Revision History Release Date Jan 23, 2004 May 14, 2004 Revision Level Rev. A Rev. A.01 Rev. B Comments Initial Draft Revised layout (no formatting) Separated sections to independent manuals Significant updates to all text and graphics Correct battery part number in section 4.0 Updated cabinet figures in section 4.0 Minor update to SIM interface in AC Power Wiring Diagrams in section 4.1 Inserted all new documentation for sections 4.7.2 to end of document 3. Introduction 3.1 Symbols - Warnings, Cautions, and Notes Warnings, Cautions, and Notes are found throughout this manual where applicable. The associated icons are used to quickly identify a potential condition that could result in the consequences described below if precautions are not taken. Notes clarify and provide additional information to assist the user. Warning This warning symbol means danger. You are in a situation that could cause bodily injury. Before you work on any equipment, be aware of the hazards involved with electrical and RF circuitry and be familiar with standard practices for preventing accidents. Caution This caution symbol means reader be careful. In this situation, the user might do something that could result in equipment damage or loss of data. Note This note symbol means reader take note. Notes contain helpful suggestions or references to material not covered in the document. Procedures are not contained in notes. 3.2 Equipment Changes Powerwave Technologies, Inc. reserves the right to make changes to the subject equipment, including but not necessarily limited to component substitution and circuits. Changes that impact this manual may subsequently be incorporated in later revisions. 3.3 System Components and Documents The table lists the model numbers and descriptions of the major components that comprise the OPAF system and the document number of the manual related to each component. 044-05156 Rev C Major System Components Model OPAF-1923-P07C01 Manual 044-05156 044-05162 044-05163 044-05164 044-05122 044-05121 Description Reference Manual Maintenance & Troubleshooting Manual Site Preparation & Installation Manual Field Replaceable Units Manual MCPA Subrack System Interface Module Fan Interface Module 148-Amp Rectifier Low Voltage Disconnect Back-Up Battery Fuse, 600A, 170 VDC or less G3S-1900-125 MCR21929-1-2 800-08824-001 800-09088-001 930-00018-005 * 920-00360-002 * 920-00337-003 TPL-CZ ** * Manufactured by Cherokee International ** Manufactured by Bussmann® Telpower®, Cooper Bussmann, Inc. St. Louis, MO Quantity per system 4. System Functional Description The OPAF-1923-P07C01 is an AC powered, linear, feed-forward multicarrier power amplifier system that operates in the 60 MHz frequency band from 1930 MHz to 1990 MHz with an instantaneous bandwidth of 25 MHz. It consists of: • One outdoor enclosure assembly. • Up to six model G3S-1900-125 amplifiers (two per sector, each mounted in an MCR21929-1-2 two-way subrack). • Six Duplexer Low Noise Amplifier modules • Four 930-00018-005, 148-amp rectifiers. • One Low Voltage Disconnect system. • Four 12 Vdc 105 AH Batteries . • System Interface Module Designed for outdoor use, the IP54 rated enclosure is a sturdy aluminum cabinet with front and rear locking ventilating doors. Access to the RF, and alarm cabling is located at the lower sides and rear of the enclosure. Access to the AC power cabling is located at the left side AC panel of the enclosure The enclosure protects the Powerwave equipment from the outdoor elements as well as housing the System Interface Module (SIM) and the electrical interface for the 148-amp rectifiers and G3S-1900-125 MCPAs (Multicarrier Power Amplifiers). The all solid-state G3S-1900-125 plug-in amplifier module MCPAs, , are designed to produce high-peak power output. The modular construction and unique and highly effective Light Emitting Diode (LED)-based operation and fault indicators always display the current operating status of the amplifiers. The turn-on and turn-off sequence of voltages are fully automatic, as is overload protection and recycling. A nominal 52-Amps of current is required for the G3S-1900-125 amplifier at rated output power. Each of the three MCR21929-1-2 subracks, contain up to two MCPAs. The MCPA outputs are combined to provide one composite output per subrack. Each subrack is equipped with an Automatic Power Control (APC) circuit and an RF GAIN ADJUST potentiometer. The APC indicator and GAIN ADJUST potentiometer are located on the upperright front of the subrack. Each subrack provides two RS-485 alarm interface ports, a preamp alarm interface port, a Form-C alarm interface port and an RS-232 maintenance port, as well as, RF IN, RF OUT and a –50dB RF sample port. The 148-amp rectifiers and associated subracks require primary input power between 176 to 264 Vac. The rectifier converts the AC input power to the +27 VDC for use by the system. The system design provides 12 minutes of battery backup time with P/N 920-00337-003 batteries under a full operational load (3 hrs 30 mins. under a light load). A Low Voltage Disconnect (LVD) monitors the output voltage of the battery system and disconnects the batteries from the circuit 044-05156 Rev C when the battery voltage drops below 21 VDC. The LVD also provides the trickle charge path for the batteries during recovery and normal operation. The System Interface Module (SIM) monitors the performance and alarm state of the rectifiers, amplifier subracks, and Duplexer Low Noise Amplifier (DLNA) modules. OPAF Front Isometric View and 044-05156 Rev C Rear Isometric View OPAF Front View with Dimensions OPAF Bottom View with Dimensions 044-05156 Rev C OPAF Left Side View and Right Side with Dimensions 044-05156 Rev C OPAF Front View with Door Removed 044-05156 Rev C 10 OPAF Rear View with Door Removed 044-05156 Rev C 11 MCR21929-1-2 Subrack Front and Rear Isometric View Host Address and Configuration Switches (Covered) APC LED Indicator RS232 Port MCR21929-1-2 Front View without Amplifiers 044-05156 Rev C 12 Gain Adjust MCR21929-1-2 Subrack Interface Connectors Release Latch G3S-1900-125 Multi-Carrier Power Amplifier Isometric View 044-05156 Rev C 13 G3S-1900-125 Multi-Carrier Power Amplifier- Front, Side and Rear Views DLNA Dimetric View 044-05156 Rev C 14 DLNA Front Panel DLNA Side View Panel System Interface Module 044-05156 Rev C 15 Rear Front 148-Amp Rectifier Isometric Views Rear Front 148-Amp Rectifier Tray and Panel Views 044-05156 Rev C 16 Low Voltage Disconnect (LVD) Module P/N 920-00337-003 Back-Up Battery 4.1 Cabinet Overview This section contains a functional description of the Powerwave OPAF Outdoor Multi-Carrier Power Amplifier (MCPA) System. Refer to the system block diagrams below. A complete OPAF system consists of a combined three-sector configuration that includes six G3S-1900-125 MCPA, 125-Watt amplifiers and three 4 KW (148-Amp), six Duplexer LNA (DLNA) assemblies, a System Interface Module (SIM), four 220 VAC AC to +27 VDC rectifiers, a Low Voltage Disconnect (LVD) assembly, four backup batteries and one outdoor enclosure. The cabinet is equipped with four lifting bosses on the top panel. The lifting bosses are designed to carry six-times the weight of the cabinet and its full contents, providing the weight is evenly distributed between the four lifting bosses. The cabinet provides easy cable and conduit access, to eliminate the need for external cable protective materials. This eases the installation and maintenance of the cabinet. The cabinet is designed for ease of maintenance with most modules and cables accessible either from the front of the cabinet, or side panel maintenance ports. The cabinet provides 3 110 VAC GFCI courtesy outlets. 2 are incorporated in the front and rear light fixtures at the top of the cabinet, the third is located inside the AC panel. 10 amps of service is available for these three outlets. 044-05156 Rev C 17 46 Light 2 N/O Rear 48 S2 N/C 50 COM 50 44 GRN 45 49 Light 1 47 N/C 49 COM 43 1 BLU 2 RED 3 WHT 4 YEL Fan Module 1 BLU 2 RED 3 WHT 4 YEL F1 1 BLU 2 RED 3 WHT 4 YEL 1 BLU 2 RED 3 WHT 4 YEL N/O N/O AC 35 N/C Door COM 36 N/O Batt 37 Door N/C COM 38 Front S1 To SIM 34 47, 48 45, H N WHT Load 46 GFCI Outlet Line 44 43 20 H N 4 5 WHT F2 F3 F4 WHT GRN Ground Bus Neutral Bus 30 A CB 5 Rectifier 3 30 A CB 4 Rectifier 2 30 A CB 3 Rectifier 1 20 A CB 6 Surge Pro. 30 A CB 7 Rectifier 4 30 A CB 8 Rectifier 5 15 A CB 9 Main Bus Battery Heater 15 A CB 2 GFCI 21 BLK Line Line Line EMI Filter Line 41 42 N/O Rear N/C Door COM To Fan Module Battery Heater 26 Line 25 Line 27 GND 23 Line 22 Line 16, 20 18, 21 24 GND 22 23 25 26 28 29 BLK 14 Line 13 Line 15 GND 11 Line 10 Line 19 17 12 GND Neutral Bus Neu 40 N/O Front N/C Door COM 34 16 Surge 17 Protector 2 32 BLK 30 1 SIM BLK WHT19 33 31 1 Surge 2 BLK Protector 18 BLK *61 Customer AC Input 29 30, 31 150 A Main CB 1 GND GRN 14 13 11 10 28 AC Relay BLK 27 24 15 12 RED 39 BLK GRN Line Line GND 4 KW (148 Amp) Rectifier 930-00018-005 4 KW (148 Amp) Rectifier 930-00018-005 4 KW (148 Amp) Rectifier 930-00018-005 4 KW (148 Amp) Rectifier 930-00018-005 4 KW (148 Amp) Rectifier 930-00018-005 04-0064W-C *Ground Warning When connecting to the main service transformer, connect main ground and wire #61 to the Neutral bus. When connecting to another AC panel, this becomes a sub-panel. Connect main ground to the Ground Bus and disconnect wire #61 at the Neutral bus. Insulate the bare wires on #61 wire. Failure to disconnect wire #61 may cause a ground loop and a safety hazard, resulting in injury or equipment damage. 4.2 AC Power Distribution Simplexed transmit RF input is provided by the BTS to the OPAF input bulkhead. The transmit signals are combined (in the 16x16 configuration), amplified, then duplexed with the receive signals. The duplexed signals are presented to a bulkhead connector for interface with the antenna port. The duplexer provides coupled samples of the forward and reflected signals for BTS diagnostics. Received signals from the duplexed antenna are separated from the transmit signals in the DLNA. The receive signals are amplified by 45 dB through a low noise amplifier. The output signal is split into two paths, to allow for future system expansion. Each sector has two DLNAs, one for the primary receive path and one for the diversity receive path. The diversity DLNA only has transmit signals when the sector is expanded beyond eight carriers. The SIM assembly monitors the MCPAs, LNAs, LVD, and rectifiers, and reports alarms via the I2C and DALI interface. 044-05156 Rev C 18 Controller +53.4dBm F WD TX +49dBm +12VDC -0.1dB I2C I2Cm Antenna Power Levels: TX: +52.0dBm (160W) 8 Carriers @ +43.0dBm/Carrier RX: -23.0dBm Max/Carrier -14.0dBmComposite System Interface Module L/A -0.1dB Detector Circuit I 2C TX/RXm -0.8dB -0.3dB -3.0dB +52.1dBm +53.3dBm DLNA0 LNAd -0.2dB 50Ω I2C d FORM-C I2C +27VDC GND Detector Circuit RVS +27VDC GND +12VDC +27VDC GND Form-C +21.7dBm Max/Carrier +30.7dBm Composite L/A -0.1dB +30.9dBm G3S-1900-125 RS-485 RS-485 To 2nd MCPA Switch Comb. VVA_Contro VVA VVA Set @ -2.8dB to achieve max RF output -3.0dB +49dBm -0.1dB I 2C -0.1dB G3S-1900-125 Switch_ Control +5.2dBm Composite 8 Carriers @ -3.8dBm/Carrier 50 Ω TX F WD To RS-485 Controller -0.5dB -0.3dB LNAd +4.7dBm Power from SNew Cabinet with Cable Loss -0.8dB RVS MCR21929-1-2 Max Combined Power 220W (53.4dBm) +51.5 +/-0.5dB Gain Max 10 dB Dynamic Range DLNA1 -0.1dB +21.7dBm Max/Carrier +30.7dBm Composite +30.9dBm -0.2dB -0.1dB +53.3dBm RXd 04-0065B-B OPAF-1923-P07C01 RF Configuration, Single Sector Example 4.3 RF Input Signal Any number of RF input signals can be applied to the transmit RF input port, providing: the signals meet established mask requirements for any 2G or 3G wireless modulation scheme, the input signals do not cause the amplifier to be over driven, and the gain of the system meets the appropriate base station architechural requirements. The maximum input power for all carrier frequencies should not exceed the limits idicated in the system specification. The input VSWR should be 2:1 maximum (or better). 4.4 RF Output Load The load impedance should be as good as possible (1.5:1 or better) in the working band for good power transfer to the load. The amplifier is operated into a duplexer and will maintain its distortion characteristics outside the signal band even if the VSWR is infinite, provided the reflected power does not exceed one watt. A parasitic signal of less than one-watt incident on the output will not cause distortion at a higher level than the normal forward distortion (i.e. -63 dBc). 044-05156 Rev C 19 4.5 G3S-1900-125 Amplifier Module 4.5.1 Overview The G3S-1900-125 amplifier is a linear, feed-forward power amplifier that operates in the 60 MHz frequency band from 1930 MHz to 1990 MHz. It is designed to operate in two continuous frequency blocks in the PCS band or an instantaneous bandwidth of 20 MHz. A typical one-sector system is illustrated above. Each amplifier is a selfcontained plug-in module and is functionally independent of the other amplifier module. The amplifier modules are designed for parallel operation to achieve high peak power output, and for redundancy in unmanned remote locations. Each amplifier in the system can simultaneously transmit multiple carrier frequencies at 85 watts per sector, for a combined output power of 170 watts. Each amplifier output is an amplified composite signal of approximately 125 watts before losses. All phase and gain corrections are performed on the signal(s) in the individual amplifier modules. Each amplifier module has alarm and display LEDs that display the amplifier performance. If a failure or fault occurs in an amplifier module, it is displayed on the individual amplifier front panel. The amplifier typically draws 52 amps of current at rated output power, and approximately 25 amps with no RF signals applied. Be sure to turn the amplifier off before removing it from the subrack to avoid damaging the equipment or causing personal injury. 4.5.1.1 Controls, Indicators, & Interfaces Primary +27 Vdc power is applied to the amplifier via a 100-amp circuit breaker (ON-OFF) located on the left side of the amplifier front panel. The plug-in amplifier module RF control and indicators, located in the center of the amplifier front panel between the cooling fans, are shown below. The status and RF control functions are described in detail in the Amplifier Module DC Indicators RF Switch Definition table. The alarms are described in detail in the Amplifier Module RF Control and Indicators Definition table. G3S-1900-125 Amplifier Module RF Control and Indicators 044-05156 Rev C 20 Amplifier Module DC Indicators RF Switch Definition Name +27VDC Indicator +15VDC Indicator +5VDC Indicator -5VDC Indicator Function Green LED. When lit, indicates that the +27 Vdc supply is greater than +21 Vdc and less than +31 Vdc. If the +27 Vdc indicator goes out, the DC Fail indicator will illuminate. This indicates that the +27 Vdc voltage dropped below +21 Vdc. Green LED. When lit, indicates that the +15 Vdc supply is greater than +12 Vdc and less than +17 Vdc. If the +15 Vdc indicator goes out, the DC Fail indicator will illuminate. This indicates that the +15 Vdc voltage dropped below +12 Vdc or increased above +17 Vdc. Green LED. When lit, indicates that the +5 Vdc supply is greater than +2 Vdc and less than +7 Vdc. If the +5 Vdc indicator goes out, the DC Fail indicator will illuminate. This indicates that the +5 Vdc voltage dropped below +2 Vdc or increased above +7 Vdc. Green LED. When lit, indicates that the -5 Vdc supply is greater than -7 Vdc and less than -2 Vdc. If the -5 Vdc indicator goes out, the DC Fail indicator will illuminate. This indicates that the -5 Vdc voltage dropped below -7 Vdc or increased above -2 Vdc. Three position switch: Off (down position) - Turns off amplifier module. On (center position) - Normal amplifier on position. RF ON Switch Reset (up position) - When toggled to reset position, all the red LED indicators will turn on one at a time in sequence followed by all the green indicators one at a time in sequence; this will also reset the fault latches. If the switch is held in the reset position, a microcontroller reset will occur. This will be verified by the LEDs toggling state again. The switch is spring loaded to return to the normal ON position when released. If a fault occurs and the MCPA is disabled, the alarms can be cleared and the MCPA enabled by this reset position. The functions of the switch are disabled for five seconds after a power-up condition. 044-05156 Rev C 21 Amplifier Module RF Control and Indicators Definition Amplifier Alarm System Alarm (From Subrack) MCPA Disable signal (pin 4) AutoRecovery Latching LED MCPA Module Yes Red Disable Major High No Red Disable Major High No Red Enable None Low No Red Disable Major High VSWR No Red Enable None Low VSWR Yes Red Disable Major High DC Fail No Red Disable Major High No Red Disable Major High +27V DC input > 30.5 V 30.0V No Red Disable Major High +27VCD input < 21 V 21.5V Fan Fail No Red Enable Minor Low (>100 Hz Speed) Loop Fail Yes Red Disable Major High Low PWR N/A Red Enable None Low Any fan fail (<70 Hz Speed) Loop fail detected longer than 2 min Indication shown base on rack RS 485 command. Over PWR Fault Over PWR Fault High Temperature High Temperature DC Fail (Over Voltage) DC Fail (Under Voltage) Condition MCPA Module Pout None > 52 dBm (Note 1) Pin > -6 dBm software; <-12 dBm 5 dBm hardware Software Base plate <75°C temperature > 80 C Base plate temperature <75°C > 85 C Reflected and Forward Reflected or Powers both exceed Forward Power 40W. Condition exist for < 38W less than 1 minute Alarm set after alarm None state on for more than 1 minute Average Internal (Note 2) voltage out of range. None NA MCPA Module Alarm Definition: Note 1: When Over Power detected at the output: a) MCPA Module will shut down (Disable). b) Turn on red Over Power lamp. c) Latch Over Power alarm d) The MCPA Module will use a RMS detector to determine the over power fault. Note 2: The Appropriate Status lamp will turn off, indicating which voltage is out of its range. (10% range for +15V, +5V, and -5V). The amplifier module has an average output of 125 watts power (1250 watts peak power) with intermodulation products suppressed to better than -63 dBc below carrier levels. The amplifier provides an amplified output signal with constant gain and phase by adding approximately 25 dB of distortion cancellation on the output signal. Constant gain and phase is maintained by continuously comparing active paths with passive references, and correcting for small variations through the RF feedback controls. All gain and phase variations, for example those due to temperature, are reduced to the passive reference variations. The amplifier module is comprised of: Preamplifiers Two feed-forward loops with phase-shift and gain controls Main amplifier DC/DC power regulator Error amplifier Alarm monitoring, control, and display panel 044-05156 Rev C 22 4.5.1.2 Main Amplifier The main amplifier employs class AB amplification for maximum efficiency. The error amplifier and feed forward loops are employed to correct signal nonlinearities introduced by the class AB main amplifier. The error amplifier operates in class AB mode. The RF input signals are amplified by a preamp and coupled to an attenuator and phase shifter in the first feed-forward loop. The main signal is phase shifted by 180 degrees and amplified in the premain amplifier. The output from the premain amplifier is fed to the class AB main amplifier. The output from the main amplifier is typically 180 watts. The signal is output to several couplers and a delay line. The signal output from the main amplifier is sampled using a coupler, and the sample signal is combined with the main input signal and input to the second feed-forward loop. The error signal is attenuated, phase shifted 180 degrees, then fed to the error amplifier where it is amplified to a level identical to the sampled output from the main amplifier. The output from the error amplifier is then coupled back and added to the output from the main amplifier. The control loops continuously make adjustments to cancel out any distortion in the final output signals. 1st Loop Phase & Gain Pre Dist Pre Main Main Amp FWD PWR Pre Amp 2nd Loop Phase & Gain Delay Delay Phase & Gain RF Out RFL PWR Error Amp Feed Forward Loop control +15 +5 -5 +27VDC Power Supply Alarms & Display Smart Rack Front Panel G3S-1900-125 Power Amplifier Module Functional Block Diagram The 2nd loop control section obtains a sample of the distortion added to the output signals by the main amplifiers, phase shifts the signals by 180 degrees, then feeds it to the error amplifier. There it is amplified to the same power level as the input sample and coupled on to the main output signal. The final output is monitored by the 2nd loop and adjusted to ensure that the signal distortion and IMD on the final output is canceled out. The input and output of the amplifier employ two-stage, class AB amplifiers, which provide approximately 25 dB of gain in the 60 MHz frequency band from 1930 to 1990 MHz. The amplifier operates on +27 Vdc, and is mounted directly on a heat sink, which is temperature monitored by a thermal sensor. If the heat sink temperature exceeds 85°C, a high temperature fault occurs. The alarm logic controls the transistor bias voltage, which shuts down the amplifier. 4.5.1.3 Error Amplifier The main function of the error amplifier is to sample and amplify the signal distortion level generated by the main amplifier, to a level that cancels out the distortion and IMD when the error signal is coupled onto the main signal at the amplifier output. The error amplifier is a balanced multistage, class AB amplifier, has 75 dB of gain, and produces over 100-watts peak output. The amplifier operates on +27 Vdc and is mounted directly on a heat sink. 4.5.1.4 Amplifier Monitoring In the main and error amplifier modules, all normal variations are automatically compensated for by the feedforward loop control. However, when large variations occur beyond the adjustment range of the loop control, a loop fault will occur. The alarms are displayed on the front panel indicators and output via a 21-pin connector on the rear of the module to the subrack summary board for subsequent remote monitoring via the ALARMS connector. 4.5.2 Amplifier Module Cooling 044-05156 Rev C 23 Although each amplifier module contains its own heat sink, it is cooled with forced air. Four fans are used for forced air cooling and redundancy. The fans, located on the front and rear of the amplifier module, draw air in through the front of the amplifier and exhaust hot air out the back of the module. The fans are field replaceable. 4.5.3 Intermodulation The G3S-1900-125 amplifier is designed to deliver a 125-watt composite average power, multicarrier signal, occupying a bandwidth less than or equal to 20 MHz, in the bandwidth from 1930 to 1990 MHz. The maximum average power for linear operation, and thus the amplifier efficiency, will depend on the type of signal amplified. 4.5.3.1 Two Tone Intermodulation When measured with two equal CW tones spaced anywhere from 30 kHz to 20 MHz apart, and at any power level up to the average power, the third order intermodulation products will be below -63 dBc 4.5.3.2 Multitone Intermodulation Adding more tones to the signal will lower individual intermodulation products. If the frequencies are not equally spaced, the level of intermodulation products gets very low. When the frequencies are equally spaced, those products fall on top of each other on the same frequency grid. The average power of all intermodulation beats falling on the same frequency is called the composite intermodulation; it is -63 dBc or better. 4.5.4 Amplifier Monitoring The amplifier has a separate remote alarm and control connector, which may be used by the host system to monitor and control the individual amplifier modules. The status, alarm, control, and power connections on the amplifier connector are made through a 21-pin male D-Sub combo connector and are listed and described in the Amplifier Module DC and Logic Connector Definition table. A1 2 3 4 5 6 7 8 9 A3 A2 A4 10 11 12 13 14 15 16 17 DC and Logic Connector (Male, on Rear of G3S-1900-125 Amplifier Module] Amplifier Module DC and Logic Connector Definition PIN Function Description A1 A2 A3 A4 10 11 12 13 14 Power Input Power Input Ground Ground RS485 +TxD RS485 +RxD Service Loop MCPA Disabled (Summary Fault) Mod Addr 0 Mod Addr 1 TP1 Manual Download DC on stat RS485 –TxD RS485 –RxD SCL7 SDA7 FP Disable Output 15 16 17 FP RST GND Module Detect +27 Vdc (Power Contact) +27 Vdc (Power Contact) Ground (Power Contact) Ground (Power Contact) Serial Communication Data Out Serial Communication Data In TTL input to Amp. Gnd. for special test mode (Note 1) TTL signal normally low indicates MCPA enabled. A high level indicates that the MCPA has been disabled. Over Power, Over Voltage takes one second to activate the signal. TTL input to Amp. Gnd. supplied by shelf to identify slot. TTL input to Amp. Gnd. supplied by shelf to identify slot. TTL output. Future test point. GND to download manually TTL output. High indicates Amp is powered on. Serial Communication Data Out Serial Communication Data In No connection No connection Output, GND if the front panel switch is in the OFF position; +5 volts indicates the front panel switch is in the ON position. Output, GND if the front panel switch is in the RESET position; +5 volts otherwise. Ground Ground potential. Informs the subrack that an MCPA is plugged in. 044-05156 Rev C 24 Note 1: Service loop grounded allows the MCPA to be enabled or disabled by the front panel switch when not mounted in the shelf. 4.5.5 Pilot Tone Control The multi-amplifier subracks can be used to control the pilot tone frequency of the installed amplifiers. Pilot tone frequency selection is based on the intended operational band of the amplifiers per the following table. Pilot Frequency Setting Based on PCS Frequency Block of Operation Block Designator Block Pairs A-D D-B B-E E-F F-C E-C Excluding F Notes: Transmit Frequency Band (MHz) Base Station Bandwidth 1930-1945 15 1945-1950 1950-1965 15 1965-1970 1965-1970 1970-1975 1975-1990 15 1930-1950 1945-1965 1950-1970 1965-1975 1970-1990 1965-1990 Excluding: 1970-1975 20 20 20 10 20 25 Pilot (MHz) 1945.5 (A) 1950.5 (D) 1965.5 (B) 1964.5 (E) 1970.5 (5) 1969.5 (F) 1974.5 (C) 1950.5 (D) 1965.5 (B) 1970.5 (5) 1964.5 (E) 1969.5 (F) 1974.5 (C) 1. If the Block Designator has not been previously selected through serial communication on connector J10M, pilot defaults to 1960.5 MHz on the G3S-1900-80 amplifier; 1964.5 on the G3S-1900-125 amplifier 2. If the Block Designator is selected through serial interface on connector J10M, pilot frequency is moved to the appropriate spot and is stored permanently into the microprocessor until another band is changed. If the pilot tone is not moved and signals are transmitted in B-band, some traffic channels may transmit directly on the pilot tone. The pilot tone requires a guard band of 60 KHz for TDMA, 270 KHz for CDMA (IS-95), and 400 KHz for GSM. Transmitting on the pilot tone will cause the amplifier to go into Loop Fail. This will not damage the MCPA. However, CDMA customers will experience a Loop Fail in every sector where the amplifiers are installed. TDMA and GSM customers will experience intermittent Loop Fails in the sectors that use these frequencies. On the other hand, if the pilot tone is not moved and signals are transmitted in A-band (1930-1945) or C-band (1975-1990), the instantaneous bandwidth of the amplifier will be exceeded. This will cause equipment operated in the outer bands of the PCS band to experience higher intermodulation distortion, which may in turn cause them to exceed FCC emission limits. The lower end of the PCS band presents the farthest frequency span from the pilot tone, which begins at 1930 MHz; 30.5 MHz away from the pilot tone of the G3S-1900-80 amplifier; 34.5 MHz away from the pilot tone of the G3S-1900-125 amplifier. Setting the pilot tone frequency of the amplifiers requires a laptop interface program. The laptop can be connected to the multi-amplifier subrack’s RS-232 port. The multi-amplifier subrack provides the interface to the amplifiers to set their pilot frequency and stores this setting in memory. If an amplifier fails, the multi-amplifier subrack programs the pilot frequency of the replacement amplifier to that of the other installed amplifiers. Refer to the Site Preparation and Installation Manual or Field Replaceable Units manual for the pilot tone configuration procedure. Contact Powerwave to obtain a copy of the program and related instructions. 044-05156 Rev C 25 4.6 MCR21929-1-2 Amplifier Subrack 4.6.1 Overview The MCPA system is a linear, feed-forward power amplifier system that operates in the 60 MHz frequency band from 1930 to 1990 MHz with an instantaneous bandwidth of 20 MHz. It consists of an amplifier subrack with up to two 125-watt G3S-1900-125 plug-in amplifiers. The MCR21929-1-2 houses an RF power splitter/combiner and a control module that monitors the functional status of all plug-in amplifiers. Additionally, the subrack is equipped with an Automatic Power Control (APC) circuit and an RF GAIN ADJUST potentiometer. The APC indicator and GAIN ADJUST potentiometer are located on the upper front of the subrack as shown below. Each subrack provides two RS-485 alarm interface ports, a preamp alarm interface port, a Form-C alarm interface port and an RS-232 maintenance port, as well as, RF IN, RF OUT and a –50dB RF sample port. Only the two RS-485 alarm interface ports are used to report alarm status to the SIM. Subrack alarms are daisy chained together and address switches on the front panel are set to identify the appropriate sector. When two of the same model amplifiers are used, the system offers up to 218 watts of output power (after combiner insertion losses) using the 125-watt amplifier. MCR21929-1-2 (Reach-through (Pseudo) Front Access) - This 19-inch flush mount subrack has front “reach through” access to its interconnect panel located at the rear of the subrack. 4.6.1.1 Controls, Indicators, & Interfaces The location and function of the amplifier subrack controls and indicators is depicted below and described in the paragraphs that follow. MCR21929-1-2 Controls and Indicators 4.6.1.1.1 AO A3 (Address) Switch This four-position DIP switch is used for setting the external RS-485 alarm bus address. MCR21929-1-2 Address Switches 4.6.1.1.2 Config Switch This four-position DIP switch is used for selecting software features in the amplifier subrack. Refer to Gain Modes later in this section for a description. Preamplifiers are not used in this system, so the second dip switch is set to Off, as indicated below in the left two diagrams. 044-05156 Rev C 26 MCR21919-1-2 Configuration Switch 4.6.1.1.3 APC LED The LED indicator located on the top right-hand corner of the subrack serves several functions. Under normal conditions, the indicator is off. Anytime the APC function is engaged, either from an overdrive or voltage derating situation, the indicator blinks. When the overdrive or voltage derating condition is removed and all the gain is recovered, the indicator ceases to blink and remains off. During maintenance functions such as downloading firmware and detector calibration, the indicator blinks to signify the beginning and end of those functions. APC LED Sequence and Blink Rate Operation Sequence Blink Rate APC due to an overdrive On/Off 1 Hz APC due to an over voltage On/Off/Off/On 1 Hz APC due to an under voltage On/Off/Off/On 1 Hz System firmware upgrade On/Off 0.1 Hz Detector calibration On/Off 1 Hz 4.6.1.1.4 Gain Adjust This potentiometer allows the subrack gain to be attenuated 0 to 10 dB in Normal operating mode, or 0 to 3 dB in Constant Gain operation mode. Refer to Gain Modes later in this section. 044-05156 Rev C 27 MCR21929-1-2 Subrack Input/Output Connectors Reference Number Name Function DC Power Terminals GROUND Lug RF OUTPUT Connector RF INPUT Connector RF SAMPLE Connector ALARMS Connector RS-485 Connectors PREAMP Connector RS-232 Connector Base station DC power connections. Subrack chassis ground. Type-N female coax connector, RF output to TX filter and antenna. See table A-1 for power output level of one to two amplifier module systems. SMA female coax connector. RF input from combiner or TX card. See specifications for power input level. SMA female coax connector. ~ –50 dB sample of the subrack RF output. 15-pin female D-Sub connector. Permits remote monitoring of amplifier form-C dry contact alarms. 9-pin female D-Sub connector. Permits remote monitoring of RS-485 signals. 9-pin female D-Sub connector. Permits remote monitoring of preamplifier and DC converter signals. 9-pin female D-Sub connector. Permits downloading of software to the subrack and/or amplifiers. 4.6.2 Automatic Power Control (APC) The APC is a power limiting function that limits the composite output power to 0.2dB to 1.0dB greater than the rated power for the inserted MCPA combinations. If the output power of the subrack exceeds an “engage” threshold (see below) the gain is reduced. The LED indicator located on the top front-right of the subrack blinks when the APC is engaged. The gain is reduced until the output power complies with the “settle” range threshold. As the input drive reduces, the gain recovers by the amount needed to approach the nominal output power, until the original gain is achieved. Any power level in between the nominal and the engage threshold does not warrant a gain change. APC Limit Thresholds (Watts)(G3S-1900-125) MCPAs Nominal 109 218 Engage 122 244 Settle 112 222 4.6.3 Gain Modes The subrack can be operated in either standard gain or constant gain mode. The choice of two gain modes provides system design flexibility. Standard gain is the mode most often selected by system designers and is the factory default setting of the subrack. Standard gain mode changes the gain of a subrack based on the number of installed functional modules, while constant gain restricts the gain of the subrack to that of about one module, regardless of the number of modules installed. When a given sector is operated at full available power to maximize call capacity or when more system gain is needed, standard gain mode is best. At lower power level requirements or when a specific system gain value must be maintained, the system designer may elect to use constant gain mode instead. Constant gain mode maintains a consistent cell site coverage footprint while allowing N+1 redundancy and increased system reliability. By installing one more amplifier than the RF power plan requires, Constant gain mode allows for a back-up amplifier, should one of the cell site’s amplifiers become inoperable. Standard gain or constant gain is independently selectable on a sector-by-sector basis. Subrack Gain Active MCPAs 044-05156 Rev C Gain Mode Constant Standard 51.5 48 48.5 48 28 4.6.3.1 Standard Gain Overview and Application (Default Configuration) In the standard gain mode, the gain of the system is dependent on the number of amplifiers operating at a given time and the power from the amplifiers is used at or near their maximum limits. When the design of the cell site requires full power from the amplifiers installed in the subrack in order to achieve maximum call capacity, the standard gain mode should be used. For example, if the sector design calls for 150 watts (measured at the directional coupler output; assuming 1.5 dB of loss from the subrack to the directional coupler), the sector should be configured with two 125 watt amplifiers (154 watts at directional coupler; 51.5 dB subrack system gain) to take full advantage of the available power. The trade-off here, is that if an amplifier fails, the available power drops back to 77 watts, the overall gain drops by 3.0 dB, and all the transmit channel powers drop by 3.0 dB as well (i.e. 7.5 watts to 3.75 watts per channel). Gain adjustment via the front panel potentiometer is available. 4.6.3.2 Constant Gain Overview and Application In constant gain mode, the gain of the subrack remains the same, regardless of the number of amplifiers installed. Good engineering practice requires careful planning when using constant gain mode. When the design of the cell site requires much less than maximum power, but must maintain a specific radius of coverage, constant gain mode is ideal. For example, if the sector design calls for 75 watts output power at the directional coupler, the sector must be configured with two 125 watt amplifiers (87 watts; 48 dB gain) when constant gain is enabled to allow for amplifier failure. If an amplifier fails, the available power drops back to 43 watts, the subrack gain adjusts to remain 48 dB (77 watts), and all the transmit channel powers remain at the set power (i.e. 7.5 watts per channel). However, while in constant gain mode, if the sector power is set to maximum (i.e. 100 watts with two amplifiers installed), and an amplifier fails, the remaining amplifier will be over-driven and likely to go into an over power condition. Should this occur, the sector would go into APC control, the input power is attenuated (see paragraph 45), the sector’s footprint shrinks and an alarm is sent to the switch. Gain adjustment via the front panel potentiometer is available. 4.6.3.3 Gain Mode Control and Theory The MCR21929-1-2 subrack adds 3 dB of attenuation when constant gain mode is initially activated, reducing the system gain of the MCR21929-1-2 from a nominal of 51.5 dB to 48.5 dB. Therefore, whenever the gain mode is changed from standard gain to constant gain or visa-versa, the cell technician must reset the overall system gain or individual channel power. In constant gain mode, the gain of each carrier (or the system) must remain constant to avoid reducing the cell radius. When the subrack detects an amplifier failure, the amplifier subrack reduces input attenuation through the Voltage Variable Attenuator (VVA) by the amount of gain lost while the amplifier is removed from the circuit. This allows the system gain to remain constant, and allows the cell site to maintain a consistent footprint. When the replaced MCPA is enabled, attenuation is again added to the input port of the subrack by the amount of gain introduced by the replacement MCPA to maintain an overall subrack constant gain. As MCPAs are disabled and enabled, system gain is recovered within a 1-second time frame. The subrack is shipped from the factory with the configuration switch set for Standard Gain mode active. 4.6.4 Performance Derating With Lower Supply Voltage The MCPA system will operate at full power, while meeting all spectrum requirements, over a supply voltage range of 26 to 28 VDC. The MCPA System will meet derated spectrum requirements at derated output power levels over a supply voltage range of 21 to 30 VDC. MCPA System power derating levels are outlined in below. The LED indicator located on the top front right of the subrack blinks when the output power is derated. Power Derating Versus Voltage Profile 044-05156 Rev C Supply Voltage[VDC] Output Power Derating 28V ≤ V < 30V 26V ≤ V < 28V 24V ≤ V < 26V 22V ≤ V < 24V 21V ≤ V < 22V 0.5dB 0dB 0.5dB 1.0dB 1.5dB 29 As the voltage returns to nominal levels, the output power will return accordingly. Sufficient hysteresis of at least 0.1 V is included to eliminate 'toggling' at crossover voltage levels. 4.6.5 Amplifier Monitoring The amplifier alarms are displayed on the front panel indicators and output via a 21-pin connector on the rear of the module to the subrack summary board for subsequent remote monitoring via the ALARMS connector. The subrack interprets the amplifier alarms, reacts accordingly, and provides alarm status to the base station through both the Form-C and RS-485 alarm bus. Amplifier alarms may be monitored through the dry contact ALARMS 15-pin female D-sub connector on the rear of the subrack. Refer to Alarm States and ALARMS Connector Definition tables and alarm connector figures below for pin definition of the alarms connector. Alarm States Minor MCAs Installed One Fan Fault No Fan Fault No Preamp Fault One Side Preamp Fault MCAs Enabled Major Form-C Critical Major Preamp Both Sides Preamp Fault 0 = Low (no alarm) 1 = High (alarm) 4.6.5.1 Form C Alarms (not used) Form-C Alarms Connector 044-05156 Rev C Critical Preamp 30 Minor RS-485 Major Critical Cable is 24 AWG, copper wire stripped and tinned at one end. Indicated state is without DC power applied. See ALARMS Connector Definition table Alarm Cable (optional), P/N 700-00649-001 ALARMS Connector Definition PIN Alarm Type Function Minor Minor Minor Major Major Major Critical Critical Critical 10 Preamp Major 11 Preamp Major 12 Preamp Major 13 Preamp Critical 14 Preamp Critical 15 Preamp Critical Continuity with common if no fan fault Common Continuity with common if one or more fan faults on any MCPA Continuity with common if all installed MCPAs are active Common Continuity with common if one or more MCPAs are disabled Continuity with common if one or more MCPAs are active Common Continuity with common if all installed MCPAs are disabled Continuity with common if external preamp is functioning correctly Common Continuity with common if external preamp primary channel faults Continuity with common if external preamp primary and redundant channels are functioning correctly Common Continuity with common if external preamp primary and redundant channels are faulted 044-05156 Rev C 31 Operating State Closed Common Alarm State Open Common Open Closed Closed Open Common Common Open Closed Closed Open Common Common Open Closed Closed Open Common Common Open Closed Closed Open Common Common Open Closed 4.6.5.2 RS-485 Connectors (J4, J5) RS-485 signals are monitored through the RS-485 9-pin female D-sub connector on the rear of the subrack. DB9 Connector RS-485 and Preamp Connector Definition PIN Description RS-485 TX data + RS-485 TX data RS-485 RX data + RS-485 RX data Ground/Shield PIN Description No Connection No Connection No Connection Ground 4.6.5.3 Preamp Connector (J6; not used) Alarm information from the system preamplifiers are monitored through this female 9-pin sub connector located on the rear of the MCPA subrack. The OPAF-1923-P07C01 does not employ preamplifiers. Preamplifier Alarm Connector Definitions PIN Description No Connection No Connection RS-232 TX No Connection Ground/Shield PIN Description PA Major + PA Major PA Critical + PA Critical - 4.6.5.4 RS-232 Connector This port is configured for RS-232 serial communications. Refer to the DB9 figure and the RS-232 Connector Definition (J20) table for pin location and definition. The RS-232 interface is located on the front of the amplifier subrack. The purpose of this connector is to provide a system interface for upgrading firmware, displaying output power and system status, and configuration. These tasks are performed using a PC with interface software. The connector is a type DB-9. The RS-232 port is only enabled if pin 8 is grounded. Grounding pin 8 disables the two RS-485 host interface ports. Standard 8-bit, 1-stop bit, no parity, 9600 Baud provides the appropriate interface communication setting. RS-232 Connector Definition (J20) PIN Description No Connection RS-232 RX RS-232 TX No Connection Ground PIN Description No Connection No Connection Select = 0 (grounded) No Connection 4.6.6 Pilot Tone Control Refer to paragraph 4.4.5 for a full description of the amplifier pilot tone. The MCR21929-1-2 subrack can be used to control the pilot tone frequency of the installed amplifiers. Pilot tone frequency selection is based on the intended 044-05156 Rev C 32 operational band of the amplifiers and must be set during commissioning of the base station, and anytime the MCR21929-1-2 subrack is replaced. Setting the pilot tone frequency of the amplifiers requires a laptop interface program. The laptop can be connected to the MCR21929-1-2’s RS-232 port. The MCR21929-1-2 provides the interface to the amplifiers to set their pilot frequency and stores this setting in memory. If an amplifier fails, the MCR21929-1-2 programs the pilot frequency of the replacement amplifier to that of the other installed amplifiers. 4.7 DLNA 4.7.1 Duplexer Overview The Duplexer Low Noise Amplifier (DLNA) module provides Bandpass filtering for both the uplink (receive) and downlink (transmit) paths, as well as gain for the receive path and alarm monitoring for receive gain and VSWR. The DLNA presents excellent return loss on all ports with 18 dB or better. The coupled ports are accurate to +1.0 dB; the –55 dB sample port is accurate to +2.5 dB RX Main SMA-F RX Div SMA-F 45 dB Gain 1:2 RX LNA Vcc TX Vcc Gain Adjust Antenna N-F REF -40 dB TX In N-F FWD -40 dB Gain Adjust 1:2 TX Sample -55 dB Vcc +27 VDC Regulator A:D A:D Alarm RS-485 RX micro-C RS-485 TX RS-485 RX VSWR S1 VSWR Alarm Temp Sensor Vcc LNA Alarm 04-0066B-A DLNA Block Diagram 4.7.2 Receive Path Overview The receive path provides for a variable gain Low Noise Amplifier (LNA) from 43 to 45 dB. The LNA gain is controlled from a front panel 10-turn potentiometer. The LNA is set to 45 db of gain from the factory. The output of the LNA is further split into two paths, reducing the receive gain by approximately 3.3 dB, for input to the base station. The noise figure of the DLNA is typically better than 2 dB at room temperature including all DLNA components. The main receive path is used for the 8x8 configuration. The diversity receive path is used for the 16x16 configuration. A microprocessor in the DLNA monitors the current draw of the LNA. If the LNA current draw drops below a predetermined threshold, an LNA alarm is generated back to the SIM. In addition, a front panel LED is illuminated when the LNA fails. 044-05156 Rev C 33 DLNA Front Panel 4.7.3 Transmit Path Overview The transmit path receives amplified RF signals from the MCR21929-1-2 amplifier subrack. The amplified signals are filtered and duplexed with the receive signals and presented to the antenna port. The transmit filter provides 105 dB of isolation in the receive band between the transmit and antenna ports. 4.7.4 DLNA Alarms VSWR and LNA alarms for the DLNA are given on the front panel and sent via an alarm bus to the SIM. Close-up View of DLNA Front Panel Alarm indications for the DLNA are as follows: VSWR LED (ON) (ON) (ON) (OFF) Fast Flash LNA LED (ON) (OFF) Green Red Yellow Green/Red Green Green 044-05156 Rev C 34 Normal Alarm State 1 Alarm State 2 Alarm State 3 Test Mode Normal Loss of Supply voltage A front panel four-position rotary switch is provided to set the VSWR alarm threshold based on the length of cable from DLNA output (typically FSJ4 or LDF4) to the antenna foam jumper (typically 1 5/8 Heliax). The switch position is set with a jeweler’s screwdriver. As a general guide, set the switch as follows: DLNA Number Switch Position Design Tolerance (dB) Test Test Test Test Test Test Internal Cabinet Cable Loss External Cabinet Cable Loss 0.25 0.25 0.25 0.23 0.23 0.23 0.16 0.16 0.16 0.14 0.14 0.14 0.09 0.09 0.09 0.07 0.07 0.07 <0.75 >0.75, <1.75 >1.75, <2.75 <0.77 >0.77, <1.77 >1.77, <2.77 <0.84 >0.84, <1.84 >1.84, <2.84 <0.86 >0.86, <1.86 >1.86, <2.86 <0.91 >0.91, <1.91 >1.91, <2.91 <0.93 >0.93, <1.93 >1.93, <2.93 Alarm Thresholds (in dB; Return Loss) Alarm Alarm Alarm State 1 State 2 State 3 Minor Major Critical 6 +2 9.5 +2.5 12 +3 8 +2.25 11.5 +3 14 +3.5 10 +2.5 13.5 +3 16 +4 6 +2 9.5 +2.5 12 +3 8 +2.25 11.5 +3 14 +3.5 10 +2.5 13.5 +3 16 +4 6 +2 9.5 +2.5 12 +3 8 +2.25 11.5 +3 14 +3.5 10 +2.5 13.5 +3 16 +4 6 +2 9.5 +2.5 12 +3 8 +2.25 11.5 +3 14 +3.5 10 +2.5 13.5 +3 16 +4 6 +2 9.5 +2.5 12 +3 8 +2.25 11.5 +3 14 +3.5 10 +2.5 13.5 +3 16 +4 6 +2 9.5 +2.5 12 +3 8 +2.25 11.5 +3 14 +3.5 10 +2.5 13.5 +3 16 +4 4.7.5 DLNA Interface The DLNA employs a DB-15 connector to communicate via the SIM and receive input DC power. Communication is accomplished using I2C with the BTS signaling. The SIM knows whether or not all DLNAs are connected by a module detect circuit provided on each DLNA (ground on pin 9). J6 DB15 Pin Assignments PIN Description 27V 27V Ground Ground Write Protect SCL_P (RX) SDA_TX_P SDA_RX_P PIN 10 11 12 13 14 15 Description Detect Temp Out (mfg test use only) (mfg test use only) SCL_N (RX) SDA_TX_N SDA_RX_N Via I2C, the alarms can be read and an EEPROM can be both read and written too. The SIM however does read the temp sensor on the DLNA. The DLNA has an RS-232 interface that is only used during test and is not wired out to the SIM. 044-05156 Rev C 35 The LNA alarm is sensed within the LNA for both low and high current. A single open collector output is read by the micro-controller and passed on the to I2C interface. 4.8 Power Plant The power plant incorporates EMI filtering, AC surge suppression, a series of circuit breakers, load sharing rectifiers, battery backup, DC power monitoring, and a Low Voltage Disconnect transfer switch. GND Reserved DLNA 0 30 A CB Battery Heater DLNA 1 20 A CB Surge Pro. 15 A CB AC Relay 15 A CB GFCI Outlet 30 A CB GND Bus Line Line Line 150 A 30 A Main CB CB 30 A CB Line Line GND Line Line GND 30 A CB Line Line GND 30 A CB DLNA 2 DLNA 3 DLNA 4 Rectifier Alpha Amplifier Subrack 4 KW (148 amp) Rectifier Beta Amplifier Subrack (148 amp) 4 KW (148 amp) Rectifier 4 KW (148 amp) Rectifier K1 K2 Monitor K4 K1 K3 100 A Line GND Gamma Amplifier Subrack 600A LVD Line 100 A DLNA 5 4 KW Line GND Line EMI Filter Line System Interface Module 600A Connect when wired as Main Panel; Disconnect when wired as Sub-Panel (default) 30 A CB Alarm 1 Alarm 2 Alarm 3 Neutral Bus 600A Neu 4 KW (148 amp) Rectifier Customer Supplied Prewired Prewired 04-0063B-B AC / DC Power Block Diagram 4.8.1 Rectifiers A series of four 4 KW rectifiers (PN: 930-00018-005) is employed to provide the OPAF power. The rectifiers source 592 amps of combined output DC power at +27 VDC under normal operating conditions. The rectifiers are designed to operate on 180 to 264 VAC, single phase power, 47 to 63 Hz, and operate at 89% efficiency. They do not require any minimum load to operate. The rectifier system is modular in design. N+1 redundancy is built into the system, so a failure in one rectifier does not affect the performance of the base station. Each rectifier provides performance data and alarms to the LVD controller and the SIM. In addition to the 30 amp circuit breaker installed in the AC panel, each rectifier is protected by an internal 30 amp 3AG fuse. The rectifier front panel provides 3 LEDs for quick fault determination Rectifier LED Definitions LED AC Good Temperature OK DC Good 044-05156 Rev C 36 Indication Green = OK Green = OK Yellow = OK Rectifier Subrack Pin Assignments PIN Description 5 Vbs 5 Vbs rtn Module Detect Pgood On/off I share Mod-Ena 0VP tp PIN 10 11 12 13 14 15 Description AC fail V prog V1 sense I monitor Tem OK Rtn Sense No Connection 4.8.2 Batteries Should the AC input power fail for any reason, four 12 Vdc, 105 AH (rated 8-hour capacity) deep discharge Valveregulated Lead-Acid batteries provide 24 Vdc power for the entire cabinet. The LVD controller will accommodate other battery ratings, however, it is factory set for this battery. The batteries provide a minimum of 12 minutes battery backup time at 25 deg C when presented with the full cabinet load. The batteries have a wide operating temperature range of –40 to +60 deg. C. The nominal charge voltage = 2.27-2.30V/Cell or 27Volts @ 25°C with temperature compensation. nSubtract 3mV/ °C from +25 to +60°C nAdd 3mV/ °C from +25 to -40°C Battery Backup Time No. of G3S-1900-125 Modules Note MCPA Amperes 52.8 105.6 158.4 211.2 264.0 316.8 1 Battery String 2 Battery Strings (Minutes) (Minutes) 90 210 37.5 90 20 52 12 37.5 26 20 The charge rate of the batteries is set for C/10 for the batteries delivered with the system. If for any reason a different type of battery is installed in the system, charge must be changed to avoid improper charging of the batteries. 044-05156 Rev C 37 Battery Recharge Cycle from Full Discharge (1.75 V/Cell) to 100% Charge Charger Capacity Battery Voltage Ba tte Constant Current Stage yC ur re nt Absorpation Mode Float Mode Time Recharge Time 4 x 4KW Modules G3S-1900-125 MCPA Load Time to 80% Recharge (Hours) MCPA 52.8 0.38 MCPA 105.6 0.36 MCPA 158.4 0.35 MCPA 211.2 0.38 MCPA 264 0.38 MCPA 316.8 0.42 The batteries meet: UL, NEBS, and EUROBAT requirements and have a 10 year plus classification compliance. They have also been tested in accordance with BS6290 Part 4. Two 600A fuses (Bussmann PN: TPL-CZ), located in the LVD, protect the batteries. 4.8.2.1 Battery Heater The battery heater is a thin, sheet-like element located between metal panels directly beneath the batteries. The battery heater receives 240 volts AC (400 W) directly from the AC panel circuit breaker through a temperature sensitive relay. The AC contacts of the relay close when the ambient temperature in the battery compartment drops below 0 °C (32 °F) allowing the heater to warm the compartment. The heating pad is turned off when the thermostat reaches 10 °C (50 °F). A separate temperature probe is placed in the battery compartment that is used by the LVD to adjust the charge voltage, and is independent of the battery heater. The battery heater generates 400 watts (1367 BTUs) of heat and has a maximum surface temperature of 200 ºC or 392 ºF. 4.8.3 Power Plant Monitoring A controller card in the LVD monitors the performance of the rectifiers. When each rectifier’s sense line is connected to the LVD, the rectifier is slaved to the control card for the final output voltage. Therefore, both the sense line and +27 Vdc bus between the LVD and the rectifier must be connected for the rectifier to supply the correct voltage to the system. The LVD control module may control up to 6 rectifier modules and adjusts rectifier output to the recommended battery float voltage for a given temperature. The LVD controller ensures that the rectifier outputs are balanced and monitors the rectifiers for failures. A potentiometer located on the front plate of the controller sets the float voltage at 25°C (77°F). The factory preset is 27.6 Vdc. Failures are reported to the SIM. 044-05156 Rev C 38 The controller also monitors the battery compartment temperature. The output bus voltage is adapted with consideration to the temperature changes of the batteries. The compensation slope is user selectable as one of three values: -36mV/°C (-20mV/°F), –60mV/°C (-33.3mV/°F), and between -10°C (14°F) and 60°C (140°F). The factory setting is –36mV (-3mV/°C/cell). If the probe is not connected or fails to open, the output voltage falls back to factory preset and an alarm is generated. The LVD controller card switch settings are given in the table below. 044-05156 Rev C 39 Switch S1 S100 S12 S11 S9 Pos State Off Off Off Off Off On Off Off On Off Off Off Off Off Off Off Off On On Off On On On On Off Off Off Off Off Off Off Off Off Off Off Off On Off Off Off 044-05156 Rev C Note Switch S7 S5 S10 S8 S6 S4 40 Pos State Off Off Off Off Off Off Off Off On On On Off Off Off Off Off Off Off Off Off On On Off Off Off Off Off Off Off Off Off On On On Off Off Off Off Off Off Note 4.8.4 Low Voltage Disconnect (LVD) Low Voltage Disconnect Module The purpose of the LVD is to monitor the DC bus to regulate the rectifier(s) output voltage with regard to the needed operating voltage to the system, and the appropriate charge voltage for the batteries. Should AC power fail, back-up batteries are installed in the system to provide a relatively short operational period, based on the amplifier load at the time of failure. When the battery performance declines to a predefined limit (21 Vdc in this system), the LVD controller disconnects the batteries from the load through a 600 amp transfer switch. Disconnecting the batteries at this threshold prevents permanent damage to the batteries, thereby extending the battery life. Low voltage alarms sent to the base station provide sufficient time to do initiate an orderly shutdown of the base station before power is lost. LVD Rear Panel Connections 044-05156 Rev C 41 LVD Internal Component Locations The controller functions of the LVD are described in the Power Plant Monitoring section of this manual. 4.8.5 Lightning Arrestors Two lightning arrestors located in the AC electrical panel provide added protection to the cabinet when the cabinet is properly grounded. The lightning arrestors are equipped with push-button trip-resets. The lightning arrestors characteristics are given in the specifications section of this manual. Lightning Arrestor 044-05156 Rev C Circuit Breaker Panel, Top Portion 42 4.9 System Interface Module (SIM) The SIM monitors the following system attributes and alarms: Cabinet level alarms (DALI): Fan Fault Intrusion Temperature AC Fault AUX MCPA Subrack level alarms (DALI): Minor (Fan Failure) Major (Single MCPA Failure in a full subrack) Critical (All MCPAs Failed in a full subrack) Rectifier level alarms; up to 5 rectifiers (DALI): Temperature Good AC Input Good DC Power Output Module Detect MCPA level alarms (integrated with the subrack alarms): Over Power High Temperature VSWR DC Fail Fan Fail Loop Fail Low Power LVD (DALI): Transfer Switch Fuse Blown DLNA level alarms (I2C interface): LNA fault VSWR Monitor Temperature MCR 0 Surge MCR 2 VAC Rect 3 Rect 5 Rear Door MCR 3 Battery Door VAC Door LVD MCR 1 MCR 5 MCR 4 RS-485 DALI 1 Temp DALI 2 MCR 1, 3, & 5 Only System Interface Module DLNA 0-5 Temp +27 VDC Rect 4 MCR 1 µCtrl Rect 1 Rect 2 MCR 4 Fan Ctrl Front Door AC Relay Circuit Breakers I2C Main BTS I2C Diversity Seperate Breaker for each DNLA 04-0107B-A DLNA 0 DLNA 2 DLNA 4 DLNA 1 DLNA 3 System Interface Module Interconnect & Block Diagram 044-05156 Rev C 43 DLNA 5 System Interface Module Front and Rear Panels All input/output connections of the SIM are detailed below: I/O J1 J2 J3 J4 J5 J6 J7 J8 J9 J10 J11 J12 J13 J14 J15 J16 J17 J18 J19 J20 J21 Description MCPA0 Serial Interface MCPA1 Serial Interface MCPA2 Serial Interface MCPA3 Serial Interface MCPA4 Serial Interface MCPA5 Serial Interface DLNA0 (Main) Interface DLNA1 (Diversity) Interface DLNA2 (Main) Interface DLNA3 (Diversity) Interface DLNA4 (Main) Interface DLNA5 (Diversity) Interface Rectifier Interface DC Input DALI1 BTS Interface DALI2 BTS Interface DLNA Main BTS Interface DLNA Diversity BTS Interface Cabinet – Intrusion and AC Fault Interface Cabinet – Fan Interface PC RS232 Interface Connector Type DB-9F DB-9F DB-9F DB-9F DB-9F DB-9F DB-15F DB-15F DB-15F DB-15F DB-15F DB-15F DB-9M 2X2 Molex DB-25F DB-25F DB-25F DB-25F DB-15F DB-15F DB-9F 4.9.1 Amplifier Alarms - MCPA Serial Interface (J1 – J6) The MCPA Serial Interface is accomplished via a DB9 Female connector on J1. The SIM communicates with each amplifier subrack in the cabinet via the host RS-485 interface on the MCPA subrack. RS-485 signals are daisy chained from the first subrack to the next, and so on, until the buss is terminated. The SIM is internally terminated, as are each of the amplifier subracks, to prevent loading down the RS-485 buss. TBD alternate configuration: The MCPA Serial Interface is accomplished via six identical DB9 Female connectors. The SIM communicates with each amplifier subrack in the cabinet via the host RS-485 interface on the MCPA 044-05156 Rev C 44 subrack. The SIM is internally terminated, as are each of the amplifier subracks, to prevent loading down the RS485 buss. Pin # Description RS-485 TX data + RS-485 TX data RS-485 RX data + RS-485 RX data No Connection No Connection No Connection No Connection No Connection Descriptions TX and RX are in reference to the MCPA subrack. TX refers to data in to the SIM. RX refers to data out from the SIM. Amplifier alarms are reported to the SIM via the amplifier subrack RS-485 bus. The amplifier subracks are daisychained on the RS-485 bus, and the alarm bus is cabled from the subrack rear panel to the front panel subrack interface panel. Each subrack has a unique address. The subrack address is set via front panel dip switches. Refer to Amplifier Monitoring in the MCR21929-1-2 Amplifier Subrack section of this manual for available alarms. 4.9.2 DLNA Alarms - DLNA Interfaces (J7 – J12) The DLNA interface is accomplished with six DB15 Female connectors. Each connection is unique and requires coordination with the DLNAs within the cabinet. Each connector provides DC power to the DLNA, differential I2C BTS pass-through, and analog temperature signals. DC power provides the DLNA with +27±1.0 Vdc via a 5A maximum circuit breaker on four contacts (2-source, 2return). The circuit breaker also functions as the power switch to the DLNA. The differential I2C interface utilizes 6 contacts. These signals are passed-through the SIM to the BTS interface. A module detect signal is also passed through. No processing is provided or required. A single analog voltage signal (pin 10) represents the temperature of the DLNA module. The voltage potential is with respect to the DC return. The temperature conversion factor is: 0°C = 500mV +10mV/°C. PIN Description DC Source DC Source DC Return DC Return No Connection SCL+ SDA_TX+ SDA_RX+ PIN 10 11 12 13 14 15 Description Module Detect Temperature Signal No Connection No Connection SCLSDA_TXSDA_RX- 4.9.3 Power Plant Alarms - Rectifier Interface (J13) The Rectifier interface is accomplished through a single DB9 Male connector. This interface includes up to six individual rectifier faults. The faults signals are open collector. The signal impedances are defined as: Low impedance signifies normal operation High impedance signifies a fault 044-05156 Rev C 45 The open collector circuit has a 10mA limitation. The interface also includes two auxiliary TTL signals. One is an input and the other an output. The auxiliary output signal is a 74HC14 inverter output. The auxiliary signals have no function at this time. RECT6 signal represents the alarm status of the LVD controller. PIN Description GND Rectifier Fault 1 Rectifier Fault 2 Rectifier Fault 3 Rectifier Fault 4 PIN Description Rectifier Fault 5 Rectifier Fault 6 (LVD) Auxiliary TTL Input Auxiliary TTL Output 4.9.4 Cabinet Alarms 4.9.4.1 Cabinet – Intrusion / AC Fault Interface (J19) A DB15 Female connector provides the Cabinet intrusion and AC fault interface. The intrusion inputs are contact closures from all of cabinet doors: front, rear, battery, and AC service. All Common contacts are tied to the system ground. The Normally Closed contacts are pulled-up and passed to the micro-controller. A logic high signal signifies an intrusion via an open door. The AC power fault passes through to the DALI interface Common contact with reference to the BTS COMMON1. An open contact signifies an AC fault. The AC fault signal is not processed. PIN Description Ground Front Door Normally Closed Contact Front Door Common Contact Rear Door Normally Closed Contact Rear Door Common Contact Battery Door Normally Closed Contact Battery Door Common Contact AC Door Normally Closed Contact PIN 10 11 12 13 14 15 Description AC Door Common Contact AC Alarm Normally Closed Contact AC Alarm Common Contact No Connection No Connection No Connection No Connection 4.9.4.2 Cabinet Fan Control and Interface (J20) Each of the cabinet fans has a sense signal with a 50% duty cycle square wave. The frequency of the square wave signal is directly proportionate to the RPM of the fan. The speed of the fan is dependant on the applied control voltage. The rotational speed of the fan is dependent on the applied DC voltage to the control input of the fan. The control function is supported by a micro-controller. The fan control ports will be forced to 0% PWM if the front door is sensed open. The fan status will latch to the current state and all fault times will be halted and saved. Upon the sensed door closure the fan sense routine will continue where it left off. The temperature information is derived from: The DLNA temperature analog input. The MCPA serial interface. The SIM internal temperature analog input. The highest temperature measurement among these devices determines the fan setting. All four-fan control ports function identically with each other. The PWM outputs do not increment or decrement > 1 step per minute. If the +27V input is < 24V, the temperature thresholds increase by +10°C. If the voltage is less than 24V the battery back-up system is assumed the primary DC source and the system will operate at an accelerated temperature to reduce the current draw of the cabinet fans in an attempt to extend battery life. 044-05156 Rev C 46 PWM VS. Temperature PWM (%) 15 25 35 45 55 65 75 85 100 Maximum Temperature +41°C or less +42°C +43°C +44°C +45°C +46°C +47°C +48°C +49°C +50°C or greater There are three fan fault frequency thresholds related to speed control. Fan Fault Thresholds PWM (%) 100 - 50 49 - 20 < 20 Fan Fault Threshold 40Hz 15Hz 10Hz Each fan sense input is measured. If the fan frequency(s) is below the threshold (for the operating mode) for a continuous period of 1-minute a fan fault is reported to the DALI interface. Any change in fan status is reported to the BTS in real-time via the I2C interface. The fan fault on the DALI is cleared when all of the fan frequencies maintain above threshold performance for a period of 30 seconds. Alarm monitoring will halt if the fan control is 0%PWM. When this occurs, the current alarm status latches. The cabinet fan interface is a DB15 Female connector. The interface provides fan monitor inputs, and fan control / status outputs. The fan control circuitry provides a 0 to 10Vdc signal to adjust the fan speed. Pin # Description Ground Fan1 Sense Fan3 Sense I2C Serial I/O Clock Ground No Connection Fan 2 Speed Control Fan 0 Speed Control Pin # 10 11 12 13 14 15 Description Fan 0 Sense Fan 2 Sense I2C Serial I/O Data Ground No Connection Fan 3 Speed Control Fan 1 Speed Control 4.9.4.3 RS-232 Interface (J21) The front panel of the SIM provides a RS-232 serial communication port. The RS-232 port provides for upgrading firmware, and displaying system status and configuration. These tasks are performed via PC and interface software. Upgrading firmware Display all DALI alarms Display all DLNA, MCPA and SIM temperatures in °C 044-05156 Rev C 47 Display the fan control voltage (0-10) Display the fan speed in Hz Pin # Description No Connection RS-232 TX RS-232 RX No Connection Ground Pin # Description No Connection No Connection No Connection No Connection 4.9.5 DALI Interfaces (J15 & J16) The two DALI interfaces are accomplished via two DB25 Female connectors. The DALI interface reports all of the cabinet alarms, excluding the DLNA alarms, to the BTS. The interface is made through Form-B contact with a reference provided by the BTS (COMMON1 or COMMON2). DALI PIN Signal 1 DALI0 2 DALI1 3 DALI2 4 DALI3 5 GND 6 DALI4 7 DALI5 8 DALI6 9 DALI7 10 GND 11 DALI8 12 DALI9 13 DALI10 14 DALI11 15 GND 16 DALI12 17 DALI13 18 DALI14 19 DALI15 20 GND 21 DALI16 22 DALI17 23 DALI18 24 DALI19 25 GND 26 NC 044-05156 Rev C Description MCPA0_ALARM1 MCPA0_ ALARM2 MCPA0_ ALARM3 MCPA2_ ALARM1 Ground (Common1) MCPA2_ ALARM2 MCPA2_ ALARM3 MCPA4_ ALARM1 MCPA4_ ALARM2 Ground (Common1) MCPA4_ ALARM3 RECT1 RECT2 RECT3 Ground (Common1) FAN ALARM INTRUSION HI_TEMP LO_TEMP Ground (Common1) RECT4 RECT5 RECT6 AC ALARM Ground (Common1) 48 DALI PIN Signal 1 DALI0 2 DALI1 3 DALI2 4 DALI3 5 GND 6 DALI4 7 DALI5 8 DALI6 9 DALI7 10 GND 11 DALI8 12 DALI9 13 DALI10 14 DALI11 15 GND 16 DALI12 17 DALI13 18 DALI14 19 DALI15 20 GND 21 DALI16 22 DALI17 23 DALI18 24 DALI19 25 GND 26 NC Description MCPA1_ ALARM1 MCPA1_ ALARM2 MCPA1_ ALARM3 MCPA3_ ALARM1 Ground (Common2) MCPA3_ ALARM2 MCPA3_ ALARM3 MCPA5_ ALARM1 MCPA5_ ALARM2 Ground (Common2) MCPA5_ ALARM3 OPEN OPEN OPEN Ground (Common2) OPEN OPEN OPEN OPEN Ground (Common2) OPEN OPEN OPEN OPEN Ground (Common2) 4.9.6 I2C Interfaces - DLNA Main (J17) / Diversity (J18) The two DLNA I2C BTS interfaces are accomplished via two DB25 Female connectors. The DLNA I2C interface is passes-through all of the DLNAs status and module detect signals to the BTS. The I2C interfaces are full duplex and differential (6 I/Os). I2C 044-05156 Rev C Pin 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 Signal SDA_RX_P SDA_RX_N SDA_TX_P SDA_TX_N SCL_P SCL_N DETECT NC GND SDA_RX_P SDA_RX_N SDA_TX_P SDA_TX_N SCL_P SCL_N DETECT NC GND SDA_RX_P SDA_RX_N SDA_TX_P SDA_TX_N SCL_P SCL_N DETECT NC Description DLNA_0 DLNA_0 DLNA_0 DLNA_0 DLNA_0 DLNA_0 DLNA_0 DLNA_0 DLNA_0 DLNA_2 DLNA_2 DLNA_2 DLNA_2 DLNA_2 DLNA_2 DLNA_2 DLNA_2 DLNA_2 DLNA_4 DLNA_4 DLNA_4 DLNA_4 DLNA_4 DLNA_4 DLNA_4 DLNA_4 49 I2C Pin 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 Signal SDA_RX_P SDA_RX_N SDA_TX_P SDA_TX_N SCL_P SCL_N DETECT NC GND SDA_RX_P SDA_RX_N SDA_TX_P SDA_TX_N SCL_P SCL_N DETECT NC GND SDA_RX_P SDA_RX_N SDA_TX_P SDA_TX_N SCL_P SCL_N DETECT NC Description DLNA_1 DLNA_1 DLNA_1 DLNA_1 DLNA_1 DLNA_1 DLNA_1 DLNA_1 DLNA_1 DLNA_3 DLNA_3 DLNA_3 DLNA_3 DLNA_3 DLNA_3 DLNA_3 DLNA_3 DLNA_3 DLNA_5 DLNA_5 DLNA_5 DLNA_5 DLNA_5 DLNA_5 DLNA_5 DLNA_5 5. Specifications Note This Powerwave product is designed to operate within the Normal Operating (typical operating) ranges or conditions specified in this document. Operation of this equipment beyond the specified ranges in this document may cause (1) spurious emissions that violate regulatory rules; (2) the equipment to be automatically removed from service when maximum thresholds are exceeded; or (3) the equipment to not perform in accordance with its specifications. It is the Operator's responsibility to ensure this equipment is properly installed and operated within Powerwave operating specifications to obtain proper performance from the equipment and to comply with regulatory requirements. Cabinet Specifications Material Finish Alarms Fans Electrical entry Grounding Door Locks Door and access plate seals Mounting Template Lock Tool Cable Access Plate Tool Lifting Bosses Wind Speed Solar Loading Compliance Dimensions: Footprint Overall, Doors Closed Overall, Doors Open Weight Empty Without Amplifiers, Rectifiers and Batteries Fully Loaded 044-05156 Rev C Aluminum alloy 0.12 inch (3.05 mm) thick Non-corrosive plating Intrusion for all doors 1200 CFM min; 65 dBA max with doors shut; turn-off when door is opened External AC entry box with grounding bus bar; AC power filtering Single point grounding; Interior grounding buss; all doors and cover plates provide good electrical ground. Front and Rear doors provide 3 point locking mechanisms UL-157 compliant Mylar plate; provided Thin-wall 7/16 inch nut driver Keyed T-27 Torx driver Qty 4; 6000 lbs (2721 Kg) max weight supported with proper strapping Up to 150 MPH (241.4 Km/H) Top (100 % Area): 754 W/m2 Front and one side (100 % Area): 754 W/m2 Telcordia GR-487-CORE; Bellcore GR-63-CORE 34 W x 34 D inches (863.6 W x 863.6 D mm) 42.5 W x 79.5 H x 39.4 D inches (1079.5 W x 2019.3 H x 1000.8 D mm) 59 W x 79.5 H x 105 D inches (1498.6 W x 2019.3 H x 2667.0 D mm) 400 lbs (181.5 Kg) 614.5 lbs (278.7 Kg) 1345 lbs (610 Kg) 50 G3S-1900-125 Multicarrier PCS Amplifier Functional Specifications Frequency Range Total Maximum Input Power Total Output Power Intermodulation Distortion and In-Band Spurious: RF Gain at 1930 MHz Gain Flatness: Gain Variation Over Temperature: Output Protection: Input Port Return Loss: Out of Band Spurious: Duty Cycle: 1930-1990 MHz -4 dBm 125 W typical (1 Module) -63 dBc (Min) @ +26 to +28 Vdc @ 125 Watts DC Input Power: Operating Temperature: Storage Temperature: Operating Humidity: Storage Humidity: RF Input / Output Connector Status / Alarm / Control / DC Input Connectors: Dimensions (Including handles, rear fans): Weight 044-05156 Rev C 51 60 dB ±0.5 dB @ 27 Vdc ±1 Vdc ±0.5 dB from 24 to 30 Vdc Mismatch Protected -16 dB (Min) Better than -60 dBc, +24 Vdc to +28 Vdc Continuous +27 Vdc ± 1 Vdc, 52 amps Typical, 60 Amps Max @ 125 Watts; Operational +21.0 Vdc to 30 Vdc 0 ºC. to +50 ºC. -40 ºC. to +85 ºC. 5 % - 95 % Relative Humidity (Noncondensing) 5 % - 95 % Relative Humidity (Noncondensing) Radial BMA Female Blind Mate Connector 21-Pin D-Subminiature Combo Connector 5.22 H x 16.97 W x 20.44 D inches (132.59 H x 431.04 W x 519.18 D mm) 52 lbs (23.59 Kg) MCR21929-1-2 Specifications Frequency Range Power Output / Max Input w/125W modules Duty Cycle RF Gain – Standard (±0.50 dB) RF Gain – Constant (±0.50 dB) RF Gain Adjust Gain Variation with Voltage / Freq. Gain Variation over Temperature Input Port Return Loss Subrack Noise Figure DC Input Voltage Range RF Power Derating for DC Input Voltage DC Input Current per Subrack Alarms (Subrack) Alarm Indication Operating Temperature Range Storage Temperature Operating Humidity, Normal Storage Humidity Connectors DC RF Input RF Output Alarm Outputs (Form-C) RS-485 (2), Preamp (1), and RS-232 (1) Controls Indicators Dimensions: Weight: 044-05156 Rev C 1930-1990 MHz (see Pilot Tone Control section) 109 W (50.37 dBm) / 1.87 dBm (1 Module) 218 W (53.38 dBm) / 1.88 dBm (2 Modules) Continuous 48.5 dB 1 Module 51.5 dB 2 Modules 48.0 dB 0 to 10 dB Standard operating mode 0 to 3 dB Constant Gain operation mode 0 dB when preamps are employed ± 0.5 dB @ 26 to 28 VDC ±0.5 dB 13 dB (min) 34.0 dB 1 Module 31.0 dB 2 Modules + Gain Adjust Attenuation value (0-10 dB) 21 to 30 VDC (26 to 28 VDC for rated operation) 28V ≤ V < 30V 0.5 dB 26V ≤ V < 28V 0.0 dB Normal operating voltage 24V ≤ V < 26V 0.5 dB 22V ≤ V < 24V 1.0 dB 21V ≤ V < 22V 1.5 dB 104 Amps Typical, 120 Amps Max (2 Modules) @ 27 ±1 VDC Minor – Fan Fail Major – One or more MCPAs Failed Critical – All MCPAs Failed Form C Contacts, LEDs & RS-485 0 °C to + 50 °C, Ambient -40 °C to + 85 °C 0% - 80% RH (Noncondensing) 0% - 100% RH (Noncondensing) Strip-n-Poke (2 to 10 AWG) SMA Female 7/16 DIN Female 15-Pin D-Subminiature Female 9-Pin D-Subminiature Female Subrack Address Subrack Operating Mode APC (RED) 19 W x 12.17 H x 25 D inches (19 W x 12.17 H x 25 D mm) 38 lbs. Empty; 142 lbs. Fully Loaded (17.24 Empty; 64.41 Kg Loaded) 52 DLNA Specifications Electrical Characteristics Parameter Limit Unit Transmit (TX) Path specific Frequency Range 1930-1990 MHz Insertion Loss 1.2 dB Loss variation over temperature 0.4 dB In-Band Ripple (J1: TX to J2: Antenna Port) 0.7 dB Input Power, Average (J1: TX) 250 Peak Instantaneous Power Handling kW Rejection (J1: TX to J2: Antenna Port) 85 dB Rejection (J1: TX to J2: Antenna Port) 105 dB Rejection (J1: TX to J2: Antenna Port) 97 dB Rejection (J1: TX to J2: Antenna Port) 45 dB Rejection (J1: TX to J2: Antenna Port) 35 dB Inter modulation Distortion (IMD3) in TX Band -80 dBc (J1: TX to J2: Antenna Port) Isolation (J1: TX to J3:RX_01) or -59 dB (J1:TX to J4: RX_02) -34 dB Receive (RX) Path Specific (Antenna port to LNA output port) Frequency Range 1850-1910 MHz Gain (J2: Antenna to J3: RX_01) or 45.0+/- 0.5 dB (J2: Antenna to J4: RX_02) -121 to –23 dBm Dynamic power range: -121 to –26 dBm Input IP3 -8.0 dBm Input P1dB -16.0 dBm Variable attenuation, voltage controlled +0.0 /- 2.0 dB Gain variation, over temperature + 1.0 dB Gain flatness, over specified frequency range 1.7 dB 2.0 dB Noise Figure 2.5 dB Rejection (J2: Antenna to J3: RX_01) or 90 dBc (J2: Antenna to J4: RX_02) Rejection (J2: Antenna to J3: RX_01) or 40 dBc (J2: Antenna to J4: RX_02) Rejection (J2: Antenna to J3: RX_01) or 25 dBc (J2: Antenna to J4: RX_02) Rejection (J2: Antenna to J3: RX_01) or dBc (J2: Antenna to J4: RX_02) Rejection (J2: Antenna to J3: RX_01) or dBc (J2: Antenna to J4: RX_02) Rejection (J2: Antenna to J3: RX_01) or dBc (J2: Antenna to J4: RX_02) Rejection (J2: Antenna to J3: RX_01) or 90 dBc (J2: Antenna to J4: RX_02) Rejection (J2: Antenna to J3: RX_01) or 70 dBc (J2: Antenna to J4: RX_02) Rejection (J2: Antenna to J3: RX_01) or 30 dBc (J2: Antenna to J4: RX_02) Remarks Max Over entire Pass band Any given frequency Max Over Temp Continuous PIP @ an altitude of 4000 m Min over DC – 1850 MHz Min over 1850-1900 MHz Min over 1900-1910 MHz Min over 2015 – 4000 MHz Min over 4000 – 12750 MHz 2 tones @100W (+50dBm) / Tone at (J1: TX) DC – 1910 MHz 1930 – 12750 MHz at Fc=1880 MHz & Room temp) Max GMSK average power Max EDGE average power Min. (Added filter loss) Min. (Added filter loss) via front panel potentiometer Full Band Filter ripple, Filter + LNA Max at Room Temp. Max Over Temp. Min. over DC to 1720 MHz Min. over 1720 to 1820 MHz Min. over 1820 to 1830 MHz 1830 to 1850 MHz Reference = 1850 to 1910 MHz 1910 to 1930 MHz Min. over 1930 to 2050 MHz Min. over 2050 to 4000 MHz Min. over 4000 to 12750 MHz Isolation (J3: RX_01) to (J4: RX_02) 15 dB Over the specified frequency range Gain balance 0.5 dB Between (J3: RX_01) & (J4: RX_02) 044-05156 Rev C 53 Parameter Electrical Characteristics Limit Unit Inter modulation Distortion (IMD7) RX Band (J3: RX_01) to (J4: RX_02) -110 dBc -10.0 dBm -18 -18 +20 to +30 27+ 0.5 1.5:1 dB dB Vdc Vdc 1930~1990 -55±2.5 2.0 -18 MHz dB dB dB Remarks Measured @ 1870 MHz., 2 tones @100W (+50dBm)/Tone at J2: Antenna General Specification Max Input RF Input Return Loss Supply Voltage Range Supply Voltage Range DC Current VSWR Sample Port J5 Frequency Range Loss (J1: TX port to J5: Sample Port) Flatness (J1: TX port to J5: Sample Port) Output Return Loss (J5: Sample) Mechanical Connector - TX port Connector - RX Ports Connector - Antenna Port Connector - Sample Port Connector - DC power & I/O N-type F SMA F N-type F SMA F DB15 Rotary 4 position Switch LED Nominal Max. Max; Source and Load Nominal Max Max (50 ohm matched) 16.12 L x 9.50 W x 1.75 H inches (409.12 L x 241.3 W x 44.45 H mm) 9 KG (19.8 lbs) Dimensions Weight Common Environmental characteristics Characteristic RMS power with no damage to DLNA (J1: TX) 50 ohm matched. (J2: Antenna) 50 ohm matched Test Conditions Value Min Max Unit Transportation Shock IEC 68-2-27 Transportation Bounce IEC 68-2-55 Operating Altitude(Note 2) 4000 - 152 Meter AMSL Operating Temperature Range - 20 +85 ºC Storage Temperature Range - 40 +85 ºC Operating Humidity Non-condensing 95 %RH Notes: 1. Maximum ratings represent the limits beyond which damage to the device may result. Continuous operation of the device at the maximum rating limit is prohibited. 2. Max op temp may be derated by 2 degrees C/1000 ft above 2154 meters. 044-05156 Rev C 54 System Interface Module Specifications Operating Voltage Current Operating Temperature Storage Temperature Humidity Interface Signals Output Voltage Dimensions Weight +27 +0.5 VDC nominal; 20 min to 30 VDC max 5 amps typical; 7.2 amps max -40 to +80 °C -40 to +80 °C 5 to 95% RH, non-condensing @ 50 °C Form-B Open-Collector TTL, 5 V pull-up, 5 mA max Open-Collector Fan Sense, 5 V pull-up, 1 mA max Fan Control, 0 to 10 VDC typical, 12 VDC max RS-232 RS-485 DLNA use, 21 to 27 VDC, 5 amp circuit breaker protection, 6 outputs 9.5 W x 5.4 D x 5.22 H inches (241.3 W x 136.91 D x 132.56 H mm) 3 lbs (1.4 Kg) 148-Amp Rectifier Model 930-00018-005 Specifications Input Voltage Input Current Power Factor Inrush Current Harmonic Distortion Efficiency Hold-Up Time Output Voltage Range 180 / 264 Vac, 47 / 63 Hz, Single phase 25.5 Amps @ full load @180 Vac 0.99 typical 50 Amps maximum <5% total @ full load; <3% @ each harmonic 89% typical @ 230 Vac >20 ms @ low line +20.0 to +29.0 Vdc (set to +27.0 for Powerwave) Line Regulation Load Regulation Output Ripple & Noise Transient Response Start-Up Time Hold-Up time Overshoot/Undershoot Temperature Coefficient Remote On/Off 0.5% using remote sense (5% on standby voltage) 0.5% using remote sense (5% on standby voltage) < 1% P-P 3 % max deviation. 0.50 ms recovery time for a 25% load change 2 Seconds >20 ms @ low line 1% at turn on/off 0.02% per ºC Logic 1(TTL high) or open enables unit (on), Logic 0 (TTL low) or short shuts unit down (Off) Signal goes low (TTL low) 2 ms before loss of output regulation 110-140% V1, 5VSB <2.5 amps automatic recovery 29.5 to 30.5 V. Reset by cycling input power Automatic shutdown with auto recovery. Thermal shutdown point @ 95 ºC Power Fail Signal Current Limit Protection Over Voltage Protection Over Temperature Protection MTBF Output Power Good LED Indicators Operating Temperature Cooling Shock and Vibration EMI/EMC Safety Approvals Dimensions Weight 300,000 hours per Belcore standard TTL high = power good, TTL low = output out of limits DC good = green LED; temperature OK = green LED; AC good = amber LED 0 to 50 ºC @ rated output power. Supply derates linearly from 50 ºC to 65 ºC @ 2.2% per ºC Self contained ball bearing fan Per MIL STD-810F, NEBS compliant to GR 63 Core Meets EN61000-3-2, -3 CISPR22 and FCC Part 15 Class A, Bellcore GR1089-Core Meets UL1950, CSA 22.2 #650, TUV EN60950 and CE Mark 5.0 W x 16.14 D x 5.0 H inches (127.0 W x 409.96 D x 127.0 H mm) 13.5 lbs (6.12 Kg) Specifications as provided by Cherokee International, Document Number 97MS2101M, Revision A, Aug 1, 2003 044-05156 Rev C 55 LVD Specifications Electrical Specifications DC bus connection Nominal voltage User adjustable values Factory set Voltage range Bus voltage monitoring Pre alarm user value range Pre alarm Factory set Battery disconnect range Factory set Rated bus current Battery connections Number of connections Battery type (AH) Temperature compensation Temperature range Slope user adjustable values Factory set Battery protection Fuse rating ranges Factory set Battery Disconnect User settable voltage values Factory set Reconnect Battery charge current limitation; Factory set Environmental Operating temperature range Max. humidity Safety Mechanical Dimensions: Width x Depth x Height Weight Front panel Connections DC Bus Battery connection Signals connection Grounding Operating Voltage Power Thermostat Set Points Maximum Surface Temperature Dimensions 044-05156 Rev C Specification 26.5V, 26.75V, 27V, 27.25V 27V Comments At 25°C adjustable by dip switches located on the controller board when programming signal is connected rectifier programming pins 20Vdc to 30Vdc Set by dip switches on the controller 23Vdc or 25Vdc 25Vdc 21V or 22V 21Vdc 600A Nominal 40; 60; 100; 200; 300 -10°C to 60°C /(14°F to 140°F) 0; -36; -48; -60 mV/K -36mV/K 70A to 600A 600A VRLA; Capacity set by dip switches Based on temperature probe when enabled Set by dip switches on the controller Single blade fuse on each battery branch with auxiliary contacts Set by dip switches on the controller 21V or 22V 21Vdc 24V C/10 -25°C to 70°C (-13°F to 158°F) 80% non condensing Meets EN 60950; All components are UL approved when mounted in an enclosed 19 inch frame 19 W x 14.2 L x 5.25 H inches (482.6 W x 360 L x 133 H mm) 15 lbs (6.8 Kg) Fuse, Controller Maintenance access Screw connection Screw connection Sub-D 15p female M6 stud Back of the module Back of the module Back of the module Back of the module Battery Heater Specification 240 VAC 400 W Close at 0 ºC (32 ºF); Open at 10 ºC (50 ºF); tolerance + 3.3 ºC (+ 6 ºF) 200 ºC (392 ºF) 20.5 L x 20.5 W x 0.030 H inches (521 L x 521 W x 0.76 H mm) 56 12 VDC 105 AH Battery Model 920-00337-003 Specifications Cells / Volts Terminal Type Capacity @ 77 ºF (25 ºC) Operating Temperature Charging Voltage / Current Temperature Compensation Storage time from a fully charged condition Self discharge rate AC ripple from charging source Overall dimensions Weight 6 Cells / 12 Volts (DC) Threaded Copper Insert, ¼ inch 105 AH (8 hrs) to 1.75 Volts (DC) per cell -40 ºC to +60 ºC (-40 ºF to +140 ºF) 2.27 to 2.30 Volts (DC) per cell, constant voltage at a maximum current of C/4 amps nSubtract 3mV/ °C/cell above +25 °C or 1.7 mV/°F/cell above 77 °F nAdd 3mV/ °C below +25 °C or 1.7 mV/°F/cell below 77 °F 6 months at 25 °C / 77 °F; for each 9 °C / 15 °F rise, reduce storage time by half < 2% per month at 25 °C / 77 °F 1.5% peak to peak of float Inches: 21.96 L x 4.86 W x 8.93 H; mm: 558 L x123 W x 227 H 90 lbs / 41 kgs Specifications as provided by Power Battery Company, Inc., Document Number 1606-1-0310 I2R SA120-40 AC Lightning Arrestor Specifications Item Tested to Arrester class acc. to IEC 61643-1 Nominal voltage (50/60 Hz) Max. continuous operating voltage Max. discharge current at wave shape Imax (8/20) Nominal discharge current at wave shape In(8/20) Voltage protection level at In Response Time Recommended back-up fuse Short-circuit withstand capability Recommended cross-section of connecting conductors Operation temperature range Protection type acc. to CSN EN 60529 Mounting on Housing’s material Weight Potential free signal contact UOM Specification IEC 61643-1 II UN 120V UC 170V Imax 40kA UP 20kA In <850V ta <25ns 160AgL/gG IP 60kAef 25mm2 (solid) θ 16mm2 (flexible) -40 to +80 ºC IP 20 DIN rail 35mm FRNC-UL94VO Flame Rating 3.2 oz (90g) electrical strength against surrounding circuits 3750Vef electrical strength against network circuit 3750Vef insulation resistance 2x107W max. switching current ~0,5A max. switching voltage ~250V Specifications as provided by Transtector, Inc., Document Number 1458-009_Rev0 (R8-11/04/02) 044-05156 Rev C 57
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.3 Linearized : No Create Date : 2004:09:08 16:21:06-07:00 Modify Date : 2004:09:08 16:21:06-07:00 Page Count : 57 Creation Date : 2004:09:08 23:21:06Z Mod Date : 2004:09:08 23:21:06Z Producer : Acrobat Distiller 5.0.5 (Windows) Author : jdale Metadata Date : 2004:09:08 23:21:06Z Creator : jdale Title : Microsoft Word - 044-05156 Rev C Reference Manual - Paragon S-new1.docEXIF Metadata provided by EXIF.tools