Powerwave Technologies 5JS0073 Fiber-Fed Repeater/Radio Head User Manual VM10056 EN Rev P1A9 Draft
Powerwave Technologies Inc Fiber-Fed Repeater/Radio Head VM10056 EN Rev P1A9 Draft
Contents
- 1. Users Manual 1
- 2. Users Manual 2
- 3. Users Manual 3
Users Manual 2
Powerwave Fiber Optics Preface User’s Manual Fiber Optics – English VM100 56/EN – User’s Manual Rev. P1A9-Draft 2004-11 Preface Powerwave Fiber Optics This document contains descriptions of Powerwave fiber optic units. Most sections in the document do not contain comlete information for building, installation, or commissioning systems and are therefore not allowed to be used as any kind of installation or commissioning guide. Only sections specificly declared to be installation or commissioning instructions are allowed to be used for that purpose. Hardware and software mentioned in this document are subjected to continuous development and improvement. Consequently, there may be minor discrepancies between the information in the document and the performance or design of the products. Specifications, dimensions and other statements mentioned in this document are subject to changes without prior notice. Powerwave and its suppliers shall not be liable for any damages related to this product, or for any other damages whatsoever caused of the use of or inability to use any Powerwave product. This is applicable even if Powerwave has been advised of the damage risk. Under any circumstances, Powerwave's entire liability shall be limited to replace such defective software or hardware which was originally purchased from Powerwave. LinDAS is a trademark of Powerwave. Microsoft is a registered trademark of Microsoft Corporation. Windows, Windows 98, Windows NT and Windows 2000 are trademarks of Microsoft Corporation. Intel and Pentium are registered trademarks of Intel Corporation. Hayes is a registered trademark of Hayes Microcomputer Products, Inc. Other trademarks mentioned in this manual are trademarks or registered trademarks of their respective owners. Powerwave Technologies, Inc., 1801 East St. Andrew Place, Santa Ana, CA 92705 USA Phone: +1 714 466 1000 – Fax: +1 714 466 5800 – Internet: www.powerwave.com This manual or parts of it may not be reproduced without the written permission of Powerwave Technologies. Infringements will be prosecuted. All rights reserved. Copyright © Powerwave Technologies, Inc., CA 92705 USA, 1994 – 2004. ii Rev. P1A9-Draft 2004-11 VM100 56/EN – User’s Manual Powerwave Fiber Optics Preface Contents Abbreviations .................................................................................................................................. v 1. Safety ......................................................................................................................................... 1-1 Human Exposure of RF Radiation ..................................................................................... 1-3 Repeater Antennas ........................................................................................................ 1-3 Installation and Maintenance of Antenna Systems ....................................................... 1-3 Radiation Exposure ....................................................................................................... 1-4 Radiation Safety Distances ........................................................................................... 1-4 Static Electricity ................................................................................................................. 1-6 2. Introduction ............................................................................................................................... 2-1 Fiber Optics in General ...................................................................................................... 2-2 Fiber Optic Transmission Versus Electrical Transmission ........................................... 2-3 Duplex Transmission .................................................................................................... 2-4 System Building Blocks ..................................................................................................... 2-5 FON, Fiber Optic Node ................................................................................................. 2-6 FOU, Fiber Optic Unit .................................................................................................. 2-6 BMU, Base Station Master Unit ................................................................................... 2-7 RMU, Repeater Master Unit ......................................................................................... 2-7 FOR, Fiber Optic Repeater ........................................................................................... 2-7 OCM, Optical Converter Module ................................................................................. 2-8 RH, Remote Hub ........................................................................................................... 2-9 3. FON, Fiber Optic Node ............................................................................................................. 3-1 Functional Description ....................................................................................................... 3-1 Block Diagram .............................................................................................................. 3-2 R2R Communication .................................................................................................... 3-4 Gateway Node ............................................................................................................... 3-5 Alarm ............................................................................................................................ 3-5 Power ............................................................................................................................ 3-5 Backup Power ............................................................................................................... 3-5 Design ................................................................................................................................ 3-6 The FON Board ............................................................................................................. 3-6 Indicators ....................................................................................................................... 3-6 RF and Optical Ports ..................................................................................................... 3-8 Connection Ports ........................................................................................................... 3-9 Operational Control ............................................................................................................ 3-11 4. RF Over Fiber ........................................................................................................................... The RF Modulated Signal Paths ........................................................................................ Downlink RF Signal Path ............................................................................................. Uplink RF Signal Path .................................................................................................. FOU, Fiber Optic Unit .................................................................................................. Noise, Intermodulation and Dynamic Signal Range ..................................................... Simplex Transmission ........................................................................................................ Duplex Transmission ......................................................................................................... VM100 56/EN – User’s Manual Rev. P1A9-Draft 2004-11 4-1 4-2 4-3 4-8 4-10 4-11 4-12 4-13 iii Preface Fiber Optics Powerwave 5. IP Over Fiber ............................................................................................................................ 5-1 IP Network Terminology ................................................................................................... Requirements ..................................................................................................................... F-Net Characteristics ......................................................................................................... Node Units ......................................................................................................................... The FON Unit Net Interfaces ....................................................................................... Network Example .............................................................................................................. 5-2 5-3 5-4 5-5 5-6 5-7 6. Commissioning ......................................................................................................................... 6-1 Equipment Required .......................................................................................................... Commissioning the Fiber Optic System ............................................................................ Master Unit Downlink Path .......................................................................................... Slave Units ................................................................................................................... System Configuration Examples ....................................................................................... 6-1 6-2 6-2 6-3 6-6 7. Passive Devices ........................................................................................................................ 7-1 OSP, Optical Splitter ......................................................................................................... Graphic Symbol ............................................................................................................ Examples ...................................................................................................................... WDM, Wavelength Division Multiplexer ......................................................................... Graphic Symbol ............................................................................................................ Example ........................................................................................................................ Fiber Optic Cables ............................................................................................................. Powerwave Patch Cables .............................................................................................. Fiber Optic Connectors ...................................................................................................... Connector Types ........................................................................................................... Handling Connectors .................................................................................................... 7-2 7-3 7-3 7-4 7-5 7-5 7-6 7-8 7-9 7-10 7-11 8. Troubleshooting ........................................................................................................................ 8-1 Index ............................................................................................................................................... I-1 Questionnaire .............................................................................................................................. Q-1 iv Rev. P1A9-Draft 2004-11 VM100 56/EN – User’s Manual Powerwave Fiber Optics Preface Abbreviations Abbreviations used in the document, in the software and in supported hardware: 3G AGC ALI ALR ALT AMPS AR BCCH BMU BA BS BSA BSC BSel BTS CDMA CH CHA CMB CSA CSel CU CW DAMPS DAS DC DCS DFB DIA DIF DL DNS DMB DPX EEPROM EGSM ETACS ETS F2F FCC FLI F-link F-net FON FOR FOT FOU GSM GPS HW ICMP IM IP LAN LED VM100 56/EN – User’s Manual Third Generation mobile system. Automatic Gain Control. Alarm Interface (board). Powerwave low power repeater (usually called Compact repeater). Powerwave low power train repeater. Advanced Mobile Phone Service. Powerwave repeater (usually called standard repeater). Broadcast Control Channel. Base station Master Unit. Booster Amplifier. Base Station. Band Selective Amplifier (board). Band Selective Compact repeater (board). Band Selective repeater. Base station Transceiver System. Code Division Multiple Access. Central Hub. Channel Amplifier (board). Combiner CDMA/WCDMA Segment Amplifier (board). Channel Selective repeater. Control Unit (board). Continuous Wave. Digital Advanced Mobile Phone Service. Distributed Antenna System. Directional Coupler. Digital Communication System (same as PCN). Distributed Feedback. Distribution (board). Diplex Filter. Downlink (signal direction from base station, via repeater, to mobile station). Domain Name Server. Digital Multimedia Broadcasting. Duplex filter. Electrical Erasable Programmable Read Only Memory. Extended Global System for Mobile communication. Extended Total Access Communication System. European Telecommunications Standards. Fiber to Fiber link (renamed to F-link/FLI). Federal Communications Commission. Fiber Link Interface. Fiber link. Fiber network. Fiber Optic Node. Fiber Optic Repeater. Fiber Optic Transceiver. Fiber Optic Unit. Global System for Mobile communication. Global Position System. Hardware Internet Control Message Protocol. Intermodulation. Internet Protocol. Local Area Network. Light Emitting Diode. Rev. P1A9-Draft 2004-11 Preface Fiber Optics LinDAS LNA MACID MRX MS MSC NAPT NMT NS OCM OM-Online OMS OMT16 OMT32 OSP PA PEP PCN PCS PPP PSM PSTN PSU PTFE R2R R2R net RAS RCC RCM RCU RF RH RIA RMS RMU RSSI RTC RX SLW SW TACS TDMA TX UDP UL UPS VAC VDC WAN WBA WCDMA WCS WDM WLI W-link W-net WRH vi Powerwave Light Indoor Distributed Antenna System. Low Noise Amplifier (unit). Physical address to RIA or CU board (comparable with Ethernet card MACID). Measurement Receiver (board). Mobile Station. Mobile Switching Center. Network Address and Port Translation. Nordic Mobile Telephone (system). Name Server. Optical Converter Module. Operation and Maintenance Online. Operation and Maintenance System. Operation and Maintenance Terminal (replaced with OMT32). Operation and Maintenance Terminal (replaced with OM-Online). Optical Splitter. Power Amplifier (board). Peak Envelope Power. Personal Communication Network (same as DCS). Personal Communication System. Point to Point Protocol. Power Supply Module. Public Switched Telephone Network. Power Supply Unit. Polytetrafluoro Ethylene (Teflon). Repeater to Repeater (Powerwave specific network). R2R network. Remote Access Service. Remote Communication Control (unit). RF Combiner Module. Remote Control Unit. Radio Frequency. Remote Hub. Repeater Interface Adapter (board). Root Mean Square. Repeater Master Unit. Received Signal Strength Indication. Real Time Clock. Receiver Sliding Window (Powerwave specific protocol). Software Total Access Communication System. Time Division Multiple Access. Transmitter User Datagram Protocol. Uplink (signal direction from mobile station via repeater to base station). Uninterruptible Power Supply. Voltage Alternating Current. Voltage Direct Current. Wide Area Network. Wideband Amplifier (board). Wideband Code Division Multiple Access. Wideband Coverage System. Wavelength Division Multiplexer. Wire Link Interface. Wire link. Wire network. Wideband Radio Head. Rev. P1A9-Draft 2004-11 VM100 56/EN – User’s Manual Powerwave Fiber Optics 1. Safety In this chapter, the word ’repeater’ includes all Powerwave repeating units, such as repeaters, hubs and radio heads. It is necessary that any personnel involved in installation, operation or service of units included in an Powerwave repeater system understand and follow the below points. • The Powerwave repeaters are designed to receive and amplify signals from one or more base stations and retransmit the signals to one or more mobile stations. And, also to act the other way round, that is to receive signals from one or more mobile stations, amplify and retransmit the signals to the base stations. Powerwave repeater systems must be used exclusively for this purpose and nothing else. • Units supplied from the mains must be connected to grounded outlets and in conformity with the local prescriptions. • Power supply units supplied from the mains contain dangerous voltage that can cause electric shock. Disconnect the mains prior to any work in such a unit. Local regulations are to be followed when servicing such units. Authorized service personnel only are allowed to service units while the mains is connected. • All RF transmitting units, including repeaters, will generate radio signals and thereby give rise to electromagnetic fields that may be hazardous to the health of any person who is extensively exposed close to an antenna. See the Human Exposure of RF Radiation section on page 1-3. • Beryllium oxide Beryllium oxide (BeO) may be contained in power devices, for instance in dummy loads in directional couplers (DCC), in combiner units (CMB), and in attenuators on the FON board. Beryllium oxide is poisonous if present as dust or smoke that can be inhaled. Do not file, grind, machine, or treat these parts with acid. • Hydrogen fluoride Coaxial cables used in many Powerwave systems have the insulation made of PTFE, polytetrafluoro ethylene, that gives off small amounts of hydrogen fluoride when heated. Hydrogen fluoride is poisonous. Do not use heating tools when stripping off coaxial cable insulation. No particular measures are to be taken in case of fire because the emitted concentration of hydrogen fluoride is very low. VM100 56/EN – User’s Manual • A lithium battery is permanently mounted in repeater CU units, and in FON and OCM units. Due to the risk of explosion, this battery must only be removed from the board by an Powerwave authorized service technician. • NiCd batteries are mounted on the FON unit. These batteries contain environmental poisonous substances. If replaced, the old batteries should be taken care of as stated in the local prescriptions. Rev. P1A9-Draft 2004-11 1-1 Fiber Optics • Powerwave The FON unit contains a class IIIb laser transmitter that emits 2 – 5mW invisible laser radiation during operation. Avoid direct exposure from unconnected laser transmitter or fiber cord as follows: – Do not power up the FON unit if a fiber cable is not attached to the fiber output UL port, neither if a fiber cable is attached to the port but unattached in the other end. – Never look in the end of a fiber cable. The 1310nm and 1550nm laser light is not visible, so no signal identification can be made anyway. Use always an instrument, such as a power meter to detect signaling. – Never use any kind of magnifying devices that can focus the laser light to an unprotected eye. 1-2 Rev. P1A9-Draft 2004-11 VM100 56/EN – User’s Manual Powerwave Fiber Optics Human Exposure of RF Radiation This section contains a few words about repeater antennas and prescriptions for installaton and maintenance of antenna systems. Also, it describes how to calculate safety distances needed for RF radiation at different antenna power and frequencies. Repeater Antennas To be able to receive and transmit signals as described in the first bulleted paragraph on page 1-1, a repeater is connected to a donor antenna directed towards the base station, and a service antenna directed towards the coverage area. A fiber optic cable from the base station might, however, be substituted for the donor antenna. Installation and Maintenance of Antenna Systems Installation and maintenance of all repeater antenna systems must be performed with respect to the radiation exposure limits for public areas. The antenna radiation level is affected by the repeater output power, the antenna gain, and by transmission devices such as cables, connectors, splitters and feeders. Have also in mind that the system minimum coupling loss, typical between 25dB and 35dB, is determined by a standard with the purpose to protect base stations from noise and other performance dropping effects. VM100 56/EN – User’s Manual Rev. P1A9-Draft 2004-11 1-3 Fiber Optics Powerwave Radiation Exposure WHO, World Health Organization, and ICNIRP, International Commission on NonIonising Radiation Protection, have determined recommendations for radiation exposure. ICNIRP recommends not to exceed the following radiation power for public exposure: Frequency 900MHz 1800MHz 2100MHz Radiation power 4,5W/m² 9,0W/m² 10,0W/m² For antennas larger than 20cm the maximum radiation power can be calculated by using the following formula: S = -------------------2 4uSur where S = Radiation power in W/m². P = Output power in W. r = Distance between antenna and human in meter. To tackle the worst case successfully, the calculation does not consider system power reducing actions, such as power control and DTX. Figure 1-1 shows the safety distance to an antenna due to the RF radiation. The distance is depending on the antenna output power and frequency, which is illustrated with two graphs in the figure. One of the graphs applies to 4.5W/m2 (900MHz) and the other to 9.0W/m2 (1800MHz) or 10.0W/m2 (2100MHz). The safety distance range in Figure 1-1 is 0 to 1.4 meter that covers an antenna power range of 10dBm to 50dBm (0.01W to 100W). Radiation Safety Distances This section illustrates the safety distances to the antennas for some typical repeater configurations. Outdoor GSM 900MHz Repeater output power Feeder loss Antenna gain EIRP +33dBm –5dB +17dBi +45dBm The safety distance can be read to 0.75 meter in Figure 1-1 as the maximum radiation power is 4.5W/m² for 900MHz. 1-4 Rev. P1A9-Draft 2004-11 VM100 56/EN – User’s Manual Powerwave Fiber Optics 100 50 9W/m2 (1800MHz) 10W/m2 (2100MHz) 31.6 4.5W/m2 (900MHz) 40 10.0 35 3.2 30 1.0 25 0.3 20 0.1 15 0.03 10 0.01 0.1 0.2 0.3 0.4 1.0 0.5 0.6 0.7 0.8 0.9 Safety distance to antenna in meter 1.1 1.2 1.3 Antenna output power in W Antenna output power in dBm 45 1.4 Figure 1-1. Safety distance to active antenna Indoor GSM 900MHz Repeater output power Feeder loss Antenna gain EIRP +22dBm –5dB +1dBi +18dBm The safety distance can be read to 0.035 meter for 4.5W/m² (900MHz). Outdoor UMTS Standard High Power Repeater output power Feeder loss Antenna gain EIRP +38dBm –5dB +17dBi +50dBm The safety distance can be read to 0.9 meter for 10W/m² (2100MHz). Indoor UMTS Repeater output power Feeder loss Antenna gain EIRP +24dBm –5dB +3dBi +22dBm The safety distance can be read to 0.035 meter for 10W/m² (2100MHz). VM100 56/EN – User’s Manual Rev. P1A9-Draft 2004-11 1-5 Fiber Optics Powerwave Static Electricity Static electricity means no risk of personal injury but it can severely damage essential parts of the equipment, if not handled carefully. Parts on the printed circuit boards as well as other parts in the equipment are sensitive to electrostatic discharge. Never touch the printed circuit boards or uninsulated conductor surfaces unless absolutely necessary. If you must handle the printed circuit boards or uninsulated conductor surfaces, use ESD protective equipment, or first touch the chassis with your hand and then do not move your feet on the floor. Never let your clothes touch printed circuit boards or uninsulated conductor surfaces. Always store printed circuit boards in ESD-safe bags. 1-6 Rev. P1A9-Draft 2004-11 VM100 56/EN – User’s Manual Powerwave Fiber Optics 2. Introduction The first official demonstration of the fiber optics technology took place at the British Royal Society in London, 1870. It was given by natural philosopher John Tyndall. He used a container with a spout and water. As the water poured through the spout, the light from the inside of the container followed the curved water path. Figure 2-1. John Tyndall’s first guided light transmission This demonstation was the first research into guided light transmission. Ten years later, in 1880, William Wheeling patented a method to transfer light in tubes, ’piping light’ through plumbing. However, this never took off because Edison invented the light bulb. Alexander Graham Bell was, about the same time, the first ever to arrange an optical amplitude modulated transmission over 200m. This was, however, achieved by emitting light beams in free space. Graham Bell’s idea was not to use wire for telephone communication. In the decade around 1950, the first practical all-glass fibers was developed which gave a success to the technology. It was Brian O’Brien at the American Optical Company and Narinder Kapany at the Imperial College of Science and Technology in London who was first to practically use an image-transmitting fiber-scope. Narinder Kapany was the man who coined the term ’fiber optics’ in 1956. Since that time, the laser and then the semiconductor laser have been very important inventions making the technology to grow increasingly and also become a fascinating and mysterious industry, where much of the technology has been isolated from outsiders. This manual is an attempt to open the curtain for a small area of this technology – fiber optic transmission between repeaters. VM100 56/EN – User’s Manual Rev. P1A9-Draft 2004-11 2-1 Powerwave Fiber Optics Fiber Optics in General In the beginning, when fiber optics became in practical use, a ’first window’ with a wavelength of 850nm was used. It had a loss of approximately 3dB/km. As the technology developed, the ’second window’ at 1300nm became more attractive because of the lower loss, below 1dB/km. Today, the ’third window’ at 1550nm is the most attractive wavelength with a loss of 0.2dB/km for silica-based fibers. The ’second window’ at 1300nm can today, with silica-based fibers, achieve a loss of only 0.35dB/km. The following figure illustrates the three ’windows’ where the loss is low over the usable wavelength range. 10 First window Rayleigh scattering loss Second Third window window Fiber molecule absorption loss dB/km 5 Visible light 600 800 1000 1200 1400 1600 1800 2000nm Figure 2-2. The three wavelength windows Figure 2-2 illustrates the losses for the three wavelengt windows, with silica-based fibers. The large absorption peaks in the diagram are caused mainly by moisture in the fiber, and by scattering at shorter wavlengths. Figure 2-2 also shows the visible light wavelegth band, the loss curve caused by Rayleigh scattering at shorter wavelengths, and the loss curve caused by fiber molecule absorption at longer wavelengths. The wavelengts used by the FON boards in the repeaters are within the second window (1310nm) and the third window (1550nm). 2-2 Rev. P1A9-Draft 2004-11 VM100 56/EN – User’s Manual Powerwave Fiber Optics Fiber Optic Transmission Versus Electrical Transmission This section points out some differences between fiber optic transmission and electrical transmission via copper. The most signficant differences are loss, bandwidth, electromagnetic interference, security, signal quality, and weight. Low loss per km In general, optical transmission over fiber offers the lowest propagation loss but also more complexity. It also adds conversion loss for electrical-to-optical signal conversion, and conversion loss the other way round. This means that there is a break-even distance due to the propagation loss, where fiber optics starts to be more cost-effective. For repeater usage, the following suggestion can be applicable: For a distance shorter than 100m, use coaxial cable. For a distance between 100m and 1000m, let the situation determine. For a distance longer than 1000m, use fiber optics. High bandwidth High bandwidth is an advantage for fiber optics. It has a higher bandwidth than any other alternative (the immense potential bandwidth of 1tHz, that is 1012Hz). High bandwidth makes fiber optics become more and more common even on short distances as the Internet and other types of data communication demand high bandwidths. This makes fiber optic parts more and more common, which in the long run decreases the break-even distance for fiber optics usage. No electromagnetic (EM) interference As fiber consists of a non-conductive material, it is unaffected by all EM radiation. Security For the same reason that fiber is immune to EM radiation, it does not emit any EM radiation that can be detected. High signal quality Because of the immunity to EM radiation, high bandwidth, and low loss, the signal quality can be considerably better for fiber optic transmission than for electric transmission in copper. Low weight A copper cable usually has a weight of ten times that of a fiber cable. VM100 56/EN – User’s Manual Rev. P1A9-Draft 2004-11 2-3 Fiber Optics Powerwave Duplex Transmission Full duplex transmission can be performed in a single fiber by transmitting one wavelength in one direction and another wavelength in the reverse direction. A wavelength division multiplexer (WDM) in each end separates the signals to an optical transmitter and an optical receiver. This is further described in Chapter 7, Passive Devices. 2-4 Rev. P1A9-Draft 2004-11 VM100 56/EN – User’s Manual Powerwave Fiber Optics System Building Blocks This section contains short descriptions of the Powerwave fiber optic building blocks listed below. Building modules • FON, Fiber Optic Node, page 2-6. • FOU, Fiber Optic Unit, page 2-6. Repeater units VM100 56/EN – User’s Manual • BMU, Base Station Master Unit, page 2-7. • RMU, Repeater Master Unit, page 2-7. • FOR, Fiber Optic Repeater, page 2-7. • OCM, Optical Converter Module, page 2-8. • RH, Remote Hub, page 2-9. Rev. P1A9-Draft 2004-11 2-5 Powerwave Fiber Optics FON, Fiber Optic Node The FON unit is the heart of all Powerwave fiber optic repeater systems. The FON unit contains an optical transmitter and an optical receiver. No other Powerwave repeater building block has these facilities. P102 P115 P109 RX P103 P105 P111 P116 P108 P106 P104 P113 P114 Beryllium oxide hazard P110 P101 TX P130 P112 Figure 2-3. The FON unit This unit is normally part of the FOU, Fiber Optic Unit. The FON unit is detailed in Chapter 3, FON, Fiber Optic Node. FOU, Fiber Optic Unit The FOU, Fiber Optic Unit, is a complete unit for fiber optic interconnection of two or more repeaters. It is built up on a flanged plate and can be inserted in all types of LGP Allgon AR repeaters. In the simpliest configuration, it contains a FON board and a DPX filter. P102 RX P103 P115 P109 P105 P111 P116 P108 P106 P104 Beryllium oxide hazard P113 P114 P110 P101 TX P130 P112 Figure 2-4. The FOU unit Figure 2-4 shows an example of the FOU with a typical configuration. Both RF and optical devices, such as DPX filters, RF combiners, optical splitters and WDMs, can be configured on the FOU plate. The FON board is always included in the FOU. The FOU is also described in the FOU, Fiber Optic Unit section in Chapter 4. 2-6 Rev. P1A9-Draft 2004-11 VM100 56/EN – User’s Manual Powerwave Fiber Optics BMU, Base Station Master Unit A BMU is an RF repeater type equipped with a FOU that gives the repeater ability to transmit and receive optical signals on the service side. The BMU has an RF port for BTS connection and up to four fiber optic ports that can be connected to FORs. ALLGON By configuring the FOU with WDMs and OSPs, up to approximately four FORs can be fed in parallel by a BMU via double or single fiber communication. Up to approximately eight FORs can be fed with a high cover and two FOUs. RF The BMU is described, with all included sub units, block diagram, and mechanical design, in the VD203 66/EN, AR Repeaters, User’s Manual. RMU, Repeater Master Unit An RMU is an RF repeater type equipped with an FOU that gives the repeater ability to transmit and receive optical signals on the service side. The RMU has an RF port for a donor antenna and up to four fiber optic ports that can be connected to FORs. ALLGON By configuring the FOU with WDMs and OSPs, up to four FORs can be fed in parallel by a BMU via double or single fiber communication. Up to eight FORs can be fed with a high cover and two FOUs. RF The RMU is described, with all included sub units, block diagram, and mechanical design, in the VD203 66/EN, AR Repeaters, User’s Manual. FOR, Fiber Optic Repeater A FOR is an RF repeater type equipped with an FOU that gives the repeater ability to transmit and receive optical signals on the donor side. The FOR has a fiber optic donor port and an RF port for a service antenna. ALLGON RF By configuring the FOU with a splitter, another FOR can be optically connected to the same RF system. The FOR can be connected to a BMU or RMU. The FOR is described, with all included sub units, block diagram, and mechanical design, in the VD203 66/EN, AR Repeaters, User’s Manual. VM100 56/EN – User’s Manual Rev. P1A9-Draft 2004-11 2-7 Powerwave Fiber Optics OCM, Optical Converter Module The OCM is, principally, an indoor rack mounted BMU with several channels for different bands, systems, and operators. The front view of the OCM is shown in Figure 2-5. RF IN/OUT ANT STATUS LOCAL O&M OPTICAL IN/OUT A1 B1 C1 A2 B2 C2 MAINS REMOTE WLI A1 A2 A3 A4 B1 B2 B3 B4 C1 C2 C3 C4 A5 A6 A7 A8 B5 B6 B7 B8 C5 C6 C7 C8 WLI CAUTION ! MAX RF INPUT +36dBm OPTICAL CONVERTER MODULE Figure 2-5. OCM, Optical Converter Module The OCM can contain up to three FON boards, and a large number of splitter configurations. The OCM is designed to work with an RCM, RF Combiner Module, in a DAS concept, see Figure 2-6. RH RH BTS RF IN/OUT ANT STATUS LOCAL O&M OPTICAL IN/OUT A1 A2 B1 C1 B2 C2 MAINS REMOTE WLI A1 A2 A3 A4 B1 B2 B3 B4 C1 C2 C3 C4 A5 A6 A7 A8 B5 B6 B7 B8 C5 C6 C7 C8 WLI OCM CAUTION ! MAX RF INPUT +36dBm CH RF IN/OUT OPTICAL CONVERTER MODULE BTS RF IN/OUT A1 B1 C1 A1 A2 A3 A4 B1 B2 B3 B4 C1 C2 C3 C4 A2 B2 C2 A5 A6 A7 A8 B5 B6 B7 B8 C5 C6 C7 C8 RCM CAUTION ! MAX BTS RF INPUT +40dBm RF COMBINER MODULE Figure 2-6. The concept of DAS System, installation, and commissioning descriptions of the OCM are found in the VD205 03/EN, LinDAS, Installation Guide. 2-8 Rev. P1A9-Draft 2004-11 VM100 56/EN – User’s Manual Powerwave Fiber Optics RH, Remote Hub The RH is, principially, a FOR unit in a compact cabinet. The RH unit has, however, no FOU but the FON board is mounted directly in the cabinet. The RH is used in DAS systems. The front view of the RH is shown in Figure 2-7. Figure 2-7. RH, Remote Hub Figure 2-8 shows a Remote Hub cabinet inside with fiber optic cables from the OCM. P102 P103 Beryllium oxide hazard P101 LO HI ANT FON RX TX P115 P109 P104 P106 P110 P130 P105 P111 P112 P108 P113 P114 PSM Fiber optic cables from OCM. Figure 2-8. Remote hub donor fiber connection Installation and commissioning descriptions of the RH are found in the VD205 03/EN, LinDAS, Installation Guide. VM100 56/EN – User’s Manual Rev. P1A9-Draft 2004-11 2-9 Fiber Optics 2 - 10 Rev. P1A9-Draft 2004-11 Powerwave VM100 56/EN – User’s Manual Powerwave Fiber Optics 3. FON, Fiber Optic Node This chapter describes the functionality, the design, and the operational control of the FON unit. P102 RX P115 P109 P103 P105 P111 P116 P108 P106 P104 Beryllium oxide hazard P113 P114 P110 P101 TX P130 P112 Figure 3-1. The FON unit A description of RF transmission over fiber using the FON unit is found in Chapter 4, RF Over Fiber. A description of IP network using the FON unit is found in Chapter 5, IP Over Fiber. Functional Description The Fiber Optic Node, FON, is a bi-directional electrical/optical signal converter and a node in either a wire network or a fiber network. It has also functionality for: – Electrical and optical signal supervision. – Internal and external alarm handling. – RS232 interface for local PC control via an O&M software (OM-Online). – Remote control via an O&M software (OM-Online or OMS). – Interface for RCC. – Interface for WLI, wire network. – Interface for FLI, fiber optic network. – Battery backup with charger. The FON unit can be installed in all Powerwave repeaters, remote hubs, and radio heads. This section contains a description of the FON unit, including block diagram, RF paths, IP path, R2R communication, FON as gateway node, alarm handling, power, and backup power. VM100 56/EN – User’s Manual Rev. P1A9-Draft 2004-11 3-1 Powerwave Fiber Optics Block Diagram RF Path 1 RF IN P101 16dB, 8W FO TX 0 – 20dB Control Unit IP RF Path 2 RF OUT P102 16dB 0 – 20dB FO RX 16dB TEST P103 –15dB Figure 3-2. FON block diagram Figure 3-2 shows a block diagram of the FON unit. The downlink and uplink RF signal paths are described below. The control unit block contains circuitry and software for control of the RF paths, local and remote communication with O&M software, protocols for IP and R2R networks, internal and external alarm handling, power supervision, etc. The control unit has a number of input and output ports not shown in the block diagram. These ports are described in the Connection Ports section on page 3-9. RF Path 1 P102 The RF IN port (P101) is usually connected to BTS/DL in a BMU (Base station Master Unit), or to the UL amplifier in a FOR (Fiber Optic Repeater). The input frequency is 800 – 2200MHz and the input power 10 – 36dBm. P103 Beryllium oxide hazard P101 The first attenuator is a 16dB, 8W power device that is a security attenuator for the FON unit. It consists of two attenuators located under the shield, see the figure. There is a FON type without these input attenuators intended for specific configurations (described in the Uplink RF Signal Path section in Chapter 4). After the attenuator there is a software adjustable 0 – 20dB attenuator, manually set by the operator via O&M software. This attenuator is correctly set when the input power to the optical transmitter is 0dBm (examples are found in Chapter 6, Commissioning). The optical transmitter converts the electrical RF modulated signal to a 1310 or 1550nm optical RF modulated signal and injects it into a fiber for transmission to one or more fiber optic receivers. The output signal power is 2 – 5dBm, or 0.5 – 2dBm at low power (NF: 30 – 35dB and IP3: 30 – 35dBm). The IP3 is: 3-2 68dBm for channel selective repeater with 2 channels. 65dBm for channel selective repeater with 4 channels. 54dBm for band selective repeater. Rev. P1A9-Draft 2004-11 VM100 56/EN – User’s Manual Powerwave Fiber Optics RF Path 2 An optical 1310 or 1550nm input signal is received by an optical receiver. The power range for this input is between –15dBm and 1dBm optical power. To avoid receiver saturation, it should be less than 1dBm. After converting the optical RF modulated signal to an electrical RF modulated signal, it is amplified in two 16dB amplifier stages with a noise figure of 4dB each. Between the two 16dB amplifiers there is a software adjustable 0 – 20dB attenuator, manually set by the operator via O&M software. This attenuator is differently set depending on the FON usage. • If the FON unit is part of a BMU, then it is adjusted to an uplink gain that is dependent on the ratio of the BTS and the repeater coverage areas. • If the FON unit is part of a FOR, then it should be adjusted to match the repeater input amplifier power range. Examples of this are found in Chapter 6, Commissioning. The RF OUT port (P102) is usually connected to BTS/UL in a BMU, or to the DL amplifier in a FOR. The output power can be between 0dBm and 20dBm with a minimum noise (above the thermal noise) of 22dB. There is also an RF test output (P103) with an output level of 15dB below the RF OUT level. This output is intended for signal measurement without disconnecting the RF cable. IP Path The IP communication circuitry is located in the control unit. The subcarrier from the control unit is fed, via a filter, to the RF path before the optical transmitter, see Figure 3-2. In the connection point, the subcarrier is added to the RF signal. In the following optical transmitter, the RF signal with the added subcarrier is converted to an optical signal and transmitted to the connected optical receiver or receivers. A received optical RF signal with an added subcarrier is converted to an electrical signal in the optical receiver. After the first amplifier, the subcarrier passes a filter and is then fed to the IP circuitry input in the control unit. The subcarrier signal takes no power from the optical RF transmission. VM100 56/EN – User’s Manual Rev. P1A9-Draft 2004-11 3-3 Powerwave Fiber Optics R2R Communication This section describes how to use the FON unit in R2R networks. The R2R network itself, its configuration, and R2R statistics are further described in the VM100 01/EN, OM-Online, User’s Manual. The R2R (Repeater to Repeater) network is an old Powerwave specific WLI network with SLW protocol and wire interconnection (W-net). WLI stands for Wire Link Interface, W-net for Wire network. SLW (Sliding Window) is an Powerwave specific protocol developed for the R2R network. The IP network can be used in fiber networks as well as in wire networks. However, the IP wire network and the R2R wire network have different protocols and can, for this reason, not communicate with each other. R2R network characteristics FON FON FON The R2R uses a twisted pair or RS-485 bi-directional bus with a master unit and slave units. The bus is connected to the FON boards via the WLI ports, see the Connection Ports section on page 3-10. An example of an R2R network with four FON nodes is shown in Figure 3-3. FON FON FON FON RCC PSTN RCC PSTN Figure 3-3. R2R network with four FON nodes Gateway The R2R network can contain maximum 12 nodes. One or several of these nodes can be gateway nodes, that is to be able to communicate remotely with an O&M software via modem. A description of the FON unit as gateway is found in the Gateway Node section on page 3-5. The R2R network in Figure 3-3 contains two gateway nodes (connected to the PSTN). Control station All nodes in an R2R network can, and should, be configured with Control Station Capability enabled, which means that they can be the master unit if the current master unit ceases to work. 3-4 Rev. P1A9-Draft 2004-11 VM100 56/EN – User’s Manual Powerwave Fiber Optics Gateway Node A FON unit can be used as a network gateway node for IP networks as well as for R2R networks by being connected to an RCC (Remote Communication Control) unit, see Figure 3-3. The RCC unit is connected to the FON board via the RCC port, see the Connection Ports section on page 3-10. Both the FON unit and the RCC unit can be installed in all Powerwave repeaters and remote hubs. The gateway node in various repeater types is further detailed in the VM100 01/EN, OM-Online, User’s Manual. Alarm The FON unit has the same alarm and event handling as the Powerwave repeaters and remote hubs. Consequently, the entire Alarms and Events chapter in the VM100 01/EN, OM-Online, User’s Manual is applicable also for the FON unit. This includes also the four external alarms that are connected to the FON board via the Alarm port, see the Connection Ports section on page 3-9. Power The FON unit requires 6.0 –8.0V power supply. All Powerwave repeaters and remote hubs have a 7V DC power supply that is used for this purpose. This power is connected to the FON board via the Power port, see the Connection Ports section on page 3-9. Backup Power If a power failure occurs, a backup battery has capacity to supply the FON control unit with the network for up to30 minutes at room temperature. This time is intended for alarm transmission. VM100 56/EN – User’s Manual Rev. P1A9-Draft 2004-11 3-5 Powerwave Fiber Optics Design This section describes the FON board layout, including indicators, coaxial ports, optical ports, connectors, and jumpers. The FON Board The FON board is built up on a printed circuit board that also contains the battery backup. The FON board is shown in Figure 3-4. P102 P115 P109 RX P103 P105 P111 P116 P108 P106 P113 P114 P104 Beryllium oxide hazard P110 P101 TX P130 P112 Figure 3-4. The FON board Indicators FLI RX P105 P111 P116 P108 P115 P109 P106 P104 P113 P114 TX P130 FAULT OPER P110 BOOT POWER DATA WLI/R2R P112 CHARGE BATT Figure 3-5. FON indicators and ports The FON board contains the below described LED indicators. FLI (or F2F) fiber network Green LED that indicates, with a flashing light, that the unit receives data over the sub carrier. A steady light indicates that the unit does not currently receive any data, or there is no other node in the network. 3-6 Rev. P1A9-Draft 2004-11 VM100 56/EN – User’s Manual Powerwave Fiber Optics OPER Green LED that lights up approximately 15 seconds after the mains is switched on. It shows, with a steady light, that the unit is ready for operation. FAULT Red LED that flashes 15 – 20 seconds after the mains is switched on. Then, it flashes for less serious alarms (Error) and is lit with a steady light for fatal alarms (Critical). POWER Yellow LED that indicates present power. It is lit with a steady light after the mains is switched on. BOOT Red LED that is lit with a steady light when the control unit boots, that is for 10 – 15 seconds after the mains is switched on. Then, it flashes for the next 5 – 10 seconds. After that, if no error is detected, the LED is off. If an error occur, then the LED is lit. WLI (or R2R) wire network Green LED that indicates, with a flashing light, that the unit is receiving data over the sub carrier. A steady light indicates one of the following three states: The unit is currently not receiving any data. The unit is currently not a Control station. Or, there is no other node in the network. DATA Blue LED that indicates data transmission in the W-net. BATT Green LED that indicates, with a steady light, that the battery pack currently is used as power source. CHARGE Yellow LED that indicates battery charge with a steady light. VM100 56/EN – User’s Manual Rev. P1A9-Draft 2004-11 3-7 Powerwave Fiber Optics RF and Optical Ports P102 RX P103 Beryllium oxide hazard P101 TX Figure 3-6. RF and optical ports The FON board has three coaxial ports and two optical ports for the downlink and uplink RF signal. The following table shows the port numbers, connector types, and the port usages. Port Type P101 P102 P103 RX TX SMA SMA SMA DIN/APC DIN/APC Description Electrical RF input port (to the optical TX port). Electrical RF output port (from the optical RX port). Electrical RF output port (15dB below the P102 port). Optical input port (to the P102 and P103 RF ports). Optical output port (from the P101 RF port). Caution There are two power attenuators at the P101 port (under the shield) on the FON board, see Figure 3-6. These may contain beryllium oxide (BeO), which is poisonous. See Chapter 1, Safety. Beryllium oxide 3-8 Rev. P1A9-Draft 2004-11 VM100 56/EN – User’s Manual Powerwave Fiber Optics Connection Ports Except for the downlink and uplink RF ports, the FON board contains the below described connection ports. P104 – Debug This port is used only for development and debugging. P105 – Front LED indicators P105 is a 4 pole male connector used for the yellow and red LED indicators located on the front cabinet door. P106 – PC P106 is a 9 pole D-sub female RS-232 port used for local PC communication. This port has the following pinning: Pin 1 Not used (GND). Pin 2 Data from FON to PC. Pin 3 Data from PC to FON. Pin 4 DTR from PC to FON. Pin 5 GND Pin 6 DSR from FON to PC. Pin 7 RTS from PC to FON. Pin 8 CTS from FON to PC. P108 and P116 – Power Power and alarm ports for the FON board. P108 and P116 are 6 pole male connectors used for providing the FON board with power. P108 and P116 are connected in parallel for cascade connection or single use. These ports have the following pinning: Pin 1 +7V in. Pin 2 +7V backup out (controlled by P114). Pin 3 Alarm output. Pin 4 GND Pin 5 Not used. Pin 6 GND. P109 – Alarm P109 is a 7 pole male alarm connector used for external alarm sensors. This port has the following pinning: Pin 1 AIC Ground. Pin 2 AIC Ground. Pin 3 AI1 External alarm input 1 – EAL1. Pin 4 AI2 External alarm input 2 – EAL2. Pin 5 AI3 External alarm input 3 – EAL3. Pin 6 AI4 External alarm input 4 – EAL4. Pin 7 Not used. VM100 56/EN – User’s Manual Rev. P1A9-Draft 2004-11 3-9 Powerwave Fiber Optics P110 – W-link jumper This jumper is used to terminate units in a W-link. It has to be set in the parking state for all units except for the first and last units in a W-link. Parking state is shown in the figure (the pins farest away from the battery pack interconnected). The opposite state terminates the W-link. P111, P112 – WLI ports P111 and P112 are 5 pole male connectors used for interconnecting nodes in WLI-nets (IP or R2R networks). P111 and P112 are identical and connected in parallel. One of the connectors are intended to be used from the previous node, and the other connector to the next node in the network. Either of P111 or P112 can be used for the first and the last unit in the net chain. P113 – Batteries P113 is a 2 pole male connector used for the on-board backup batteries. P114 – Backup power output This jumper sets the backup power output state. The OFF state is shown in the figure (the pins closest to the battery pack interconnected). This jumper has to be in the OFF state when used in an OCM unit. Otherwise, it shall be in the ON state (opposite to the figure). P115 – Future port P115 is a 3 pole male connector intended for future use (not used for the time being). P130 – RCC port P130 is a 34 pole 2 line male connector used for connecting an RCC, Remote Communication Control unit. The P130 connector contains both the modem connection and RCC power supply. 33 3 - 10 34 Rev. P1A9-Draft 2004-11 VM100 56/EN – User’s Manual Powerwave Fiber Optics Operational Control The FON unit can be locally or remotely controlled via an O&M software (remote control via modem). All descriptions in this document refer to the OM-Online O&M software. Parameter names may differ somewhat when working with OMS, but the functionality of the parameters are the same. VM100 56/EN – User’s Manual Rev. P1A9-Draft 2004-11 3 - 11 Fiber Optics 3 - 12 Rev. P1A9-Draft 2004-11 Powerwave VM100 56/EN – User’s Manual Powerwave Fiber Optics 4. RF Over Fiber This chapter describes the downlink RF modulated signal from the BTS to the repeater antenna, and the other way around from the repeater antenna to the BTS. The description is focused on the optical part of the RF transmission. The chapter is divided into the following main parts: • • • • • • • VM100 56/EN – User’s Manual RF signal path overview for downlink and uplink signals, page 4-2. Detailed description of the downlink signal path, page 4-3. Detailed description of the uplink signal path, page 4-8. Brief description of the FOU, Fiber Optic Unit, page 4-10. Brief descriptions of noise, intermodulation, and dynamic signal range, page 4-11. Some examples of simplex transmission, page 4-12. Some examples of full-duplex transmission, page 4-13. Rev. P1A9-Draft 2004-11 4-1 Powerwave Fiber Optics The RF Modulated Signal Paths Figure 4-1 illustrates the downlink RF modulated signal path from the BTS via a BMU, optical fiber, and a FOR to the repeater antenna. And also the uplink path from the repeater antenna back to the BTS. DL DC DPX TX FOR RX FON FON RX TX DPX BMU UL BTS Figure 4-1. Downlink and uplink RF modulated signal paths As the signal paths mainly are handled by the FON units, the signal description for this unit, found in the RF Path 1 and RF Path 2 sections in Chapter 3, is applicable to the downlink and uplink RF modulated signal paths. The amplifiers and duplex filter (DPX) in the FOR are, however, not included in the FON description, but are found in the repeater manual (VD203 66/EN, AR Repeaters, User’s Manual). The signal paths are, however, also described below, but more in terms of radio frequency signals in the entire chain, from the BTS to the repeater antenna, and the other way around. 4-2 Rev. P1A9-Draft 2004-11 VM100 56/EN – User’s Manual Powerwave Fiber Optics Downlink RF Signal Path The downlink RF modulated signal path, from the BTS to the repeater antenna, is shown in Figure 4-2. The item numbers in the figure are described below. DL DC DPX TX FOR RX FON FON DPX BMU 9 10 11 12 Figure 4-2. Downlink RF transmission path 1. DC coupler BMU 20dB DC DL 40dBm BTS NF 5dB The DC coupler on the BTS antenna path picks up the BTS downlink signal with a fixed coupling loss of 20dB. The left figure shows the DC coupler connected to the BTS antenna path and the BTS downlink amplifier with a typical noise figure of 5dB. The values in the figure are typical values that can vary from one system to another. 2. DPX duplex filter DPX A Powerwave duplex filter separates the downlink and uplink signal frequencies between the BTS antenna path and the separate input/output RF ports of the FON unit. The Powerwave DPX filter has a typical loss of 1dB. 3. Power attenuator An input 16dB/8W power attenuator is a security attenuator for the FON unit. 16dB, 8W 4. Software adjustable attenuator The software adjustable 0 – 20dB attenuator is set manually via an O&M software. This is described in the FON section of the VM100 01/EN, OM-Online, User’s Manual. 0 – 20dB The attenuator should be set to a calculated value that attenuates the signal power to 0dBm to the following optical transmitter. Example: Presume the typical values in the figures above are used, that is: – – – – BTS output = 40dBm DC coupler loss = 20dB DPX filter loss = 1dB power attenuator = 16dB Set the attenuator to 3dB (40dBm – 20dB – 1dB – 16dB = 3dB). VM100 56/EN – User’s Manual Rev. P1A9-Draft 2004-11 4-3 Powerwave Fiber Optics 5. Optical transmitter The optical transmitter converts the electrical RF modulated signal to a 1310 or 1550nm optical RF modulated signal. The transmitter ends with an optical female connector. TX The transmitter has a laser diode for transmitting the optical signal, and a back-facet monitor photodiode that provides a real-time monitoring of the optical output. 10 25°C Po (mW) 0°C 50°C 20 40 60 IF (mA) 80 100 The back-facet monitor photodiode is used to control the laser treshold current that is temperature dependent. See the treshold current bends of the optical power output curves for some different temperatures in the left figure. The values shown in the diagram are typical values that can vary for diffierent devices. By using the back-facet monitor photodiode, the optical transmitter is compensated for different operating temperatures and a temperature non-dependent electrical-to-optical curve can be used, see Figure 4-3. PO PO-RF IBIAS IRF Figure 4-3. Electircal to optical signal conversion The RF modulated optical output signal PO-RF has the same shape as the RF modulated electrical input signal IRF, see Figure 4-3. The IBIAS current is set to keep the dynamic 'IRF current range within the straight part of the curve, provided the input power is kept on about 0dBm (or lower). If the input power is much higher, then the PO-RF will be distored. The output signal can be the default power range or be set to a low power range via an O&M software. Default power range means 3.5 – 5dBm, low power range 0.5 – 2dBm. The noise figure for the optical transmitter is 30 – 35dB. The IP3 level is 30 – 35dBm. 4-4 Rev. P1A9-Draft 2004-11 VM100 56/EN – User’s Manual Powerwave Fiber Optics 6. Optical transmission In the example shown in Figure 4-2, the optical downlink transmission (between the optical transmitter and the optical receiver) is built-up with two optical connectors and one single-mode fiber. The optical connectors are of DIN/APC type. The coupling loss (gap and misalignment losses) for this connector type is approximately 0.5dB. The single-mode fiber loss is approximately 0.35dB/km for 1310nm and 0.20dB/km for 1550nm. The maximum fiber attenuation should not exceed 15dB. Example: At a distance of three kilometers, the optical transmission loss for a 1310nm signal is approximately 2dB (0.5dB + 3x0.35dB + 0.5dB), and for a 1550nm signal approximately 1.6dB (0.5dB + 3x0.20dB + 0.5dB). The optical transmission loss will increase for devices used to split the signal path to more than one receiver or to use the same fiber for both transmission directions. This is further described in the Simplex Transmission section on page 4-12, and in the Duplex Transmission section on page 4-13. Note that all optical losses, except for FOT/FOT and FON/FON conversion losses, are to be multiplied by two when converting to electrical RF losses. The reason why the optical loss has to be multiplied by two (in dB) is that the light detector in the optical receiver has a square shaped input area and thus extracts the square root of the input power. VM100 56/EN – User’s Manual Rev. P1A9-Draft 2004-11 4-5 Powerwave Fiber Optics 7. Optical receiver The optical receiver performs the opposite function to the optical transmitter. It contains a light detector, that is a semiconductor photodiode that produces current in response to incident 1310 or 1550nm light. RX The conversion from an optical signal to an electrical RF signal is shown in Figure 4-4. PO PO-RF IRF Figure 4-4. Optical receiver light detector The optical input power to the light detector has to be between –15dBm and 1dBm. To avoid detector saturation that will result in signal distortion, it should be less than 1dBm. The optical output power is independent of the TX attenuation. The light detector adds very low amounts of shot noise and thermal noise. 8. Amplifier 16dB The converted electrical RF modulated signal is amplified in a 16dB amplifier with a noise figure of 4dB. 9. Software adjustable attenuator The software adjustable 0 – 20dB attenuator is set manually via an O&M software. This is described in the FON section of the VM100 01/EN, OM-Online, User’s Manual. 0 – 20dB Setting, see the following amplifier. 4-6 Rev. P1A9-Draft 2004-11 VM100 56/EN – User’s Manual Powerwave Fiber Optics 10. Amplifier 16dB The RF modulated signal is finally amplified in the last FON stage, a 16dB amplifier with a noise figure of 4dB. The output signal minimum noise (above the thermal noise) is 22dB. The output power is set with the previous adjustable attenuator to match the repeater amplifier input level (maximum 13dBm). To achieve maximum output power from the repeater, the input signal level to the repeater has to be correct with respect to the gain. The signal level is adjusted with the FON adjustable attenuator. 11. Repeater amplifier The repeater amplifier consists of a low noise amplifier, LNA, a repeater amplifer stage, and a power amplifier. These stages are described in the VD203 66/EN, AR Repeaters, User’s Manual. DPX 12. DPX duplex filter VM100 56/EN – User’s Manual Separates the downlink and uplink signal frequencies between the repeater service antenna and the separate downlink/uplink FOR amplifiers. The DPX filter is described in the VD203 66/EN, AR Repeaters, User’s Manual. Rev. P1A9-Draft 2004-11 4-7 Powerwave Fiber Optics Uplink RF Signal Path The uplink RF modulated signal path, from the repeater service antenna to the BTS, is shown in Figure 4-5. The item numbers in the figure are described below. Item numbers are omitted for those items that have the same function and settings as in the downlink path. BMU FON FON RX DC DPX DPX FOR TX UL Figure 4-5. Uplink RF transmission path 1. Repeater amplifier The repeater amplifier is the same as the downlink amplifier, but in this case the output power should be adjusted to match the FON input power range, 10 – 36dBm. 2. Power attenuator The input 16dB/8W power attenuator is the same as the downlink amplifier, but in this case an alternative configuration can be used. DPX 16dB, 8W In the alternative configuration a FON unit without this power attenuator is used. In this case a lower output power from the FOR unit is fed directly to the following adjustable attenuator. The advantage of this configuration is less signal noise. 3. Software adjustable attenuator The software adjustable 0 – 20dB attenuator is set manually via an O&M software. This is described in the FON section of the VM100 01/EN, OM-Online, User’s Manual. 0 – 20dB DPX If the BTS has a larger coverage area than the repeater, then the attenuator is usually adjusted to a total uplink gain to the BTS of –10dB (shown in the figure). DC BMU –10dB BTS 4-8 FON If the coverage area is the same for the BTS and the repeater, then the BTS antenna input sensitivity with connected repeater should be the same as the sensitivity at the repeater antenna input. The total uplink gain can, however, not be set only on the software adjustable attenuator but has to be balanced on the three uplink set points highlighted in Figure 4-6 (see the next section). Rev. P1A9-Draft 2004-11 VM100 56/EN – User’s Manual Powerwave Fiber Optics Setting the total uplink gain The three uplink set points, highlighted in Figure 4-6, have to be balanced to a total uplink gain appropriate to the ratio of the coverage areas for the BTS and the repeater. DC FOR FON FON RX TX DPX DPX BMU UL –10dB Figure 4-6. Total uplink gain setting points Coupling factors and power losses in the entire uplink chain, including the optic fiber, have also to be considered when setting the total uplink gain. A power calculator should be used when determining the uplink settings. Some examples with various settings are found in Chapter 6, Commissioning. VM100 56/EN – User’s Manual Rev. P1A9-Draft 2004-11 4-9 Powerwave Fiber Optics FOU, Fiber Optic Unit The FOU, Fiber Optic Unit, is a complete unit for fiber optic interconnection of two or more repeaters. It is built up on a flanged plate and can be inserted in all types of LGP Allgon AR repeaters. In the simpliest configuration, it contains a FON board and a DPX filter. Figure 4-7 shows a simple configured FOU, Fiber Optic Unit. FOU DPX RX FON TX Figure 4-7. The FOU, Fiber Optic Unit An FOU inserted in the BMU and in the FOR is shown in Figure 4-8. BMU FOU FOR FOU FON FON TX RX DPX DPX DC TX DPX RX BTS Figure 4-8. FOU inserted in the BMU and FOR The FOU can also be configured with optical splitters for more than one FOR in the optical network, and with WDMs for optical duplex transmission. 4 - 10 Rev. P1A9-Draft 2004-11 VM100 56/EN – User’s Manual Powerwave Fiber Optics Noise, Intermodulation and Dynamic Signal Range This section contains brief descriptions of noise, intermodulation, and dynamic signal range. Noise and intermodulation Figure 4-9 shows noise and intermodulation values for the optical transmission. Conversion loss 25dB TX FON Gain 30dB RX LFO NF = 30 – 35dB IP3 = 30 – 35dBm NFOUT FON NF = 3 – 4dB Figure 4-9. Noise and intermodulation If the fiber loss, LFO, is lower than 5dB, the output noise figure, NFOUT, is determined by the optical transmitter (’1’ in Figure 4-9). If the fiber loss, LFO, is higher than 5dB, the output noise figure, NFOUT, is determined by the receiver amplifier (2). Intermodulation and IP3 The third order of intermodulation is illustrated on a frequency axis in the figure. f1 f2 2f2–f1 DPX 2f1–f2 The formula for it reads: IM3 = 3P0 – 2IP3 dB where: IM3 = Intermodulation level. P0 = Carrier power. IP3 = The IP3 point of the amplifier. The IP3 values from the various types of repeater amplifiers are: BSA 54dBm CHA 68dBm for 2 channels, 65dBm for 4 channels. ALR 48dBm (compact repeater and RH) WRH 35dBm Dynamic signal range VM100 56/EN – User’s Manual The dynamic range for the RF signal is determined by the noise level and the IM requirements. The dynamic range is represented by a vertical arrow in the figure, where: P = Power S = Signal level. N = Noise floor + intermodulation. Rev. P1A9-Draft 2004-11 4 - 11 Powerwave Fiber Optics Simplex Transmission This section contains two examples of simplex transmission over fiber. RMU FOR BTS DL = 1310nm UL = 1310nm DL UL Figure 4-10. Simplex transmission between an RMU and a FOR unit The first example, shown in Figure 4-10, illustrates a simple configuration. This configuration is described in the previous sections in this chapter, but in this case an RMU is used for radio transmission with the BTS. The downlink and uplink wavelength is 1310nm. FOR BMU FOR FOR FOR BTS UL DL DL = 1310nm UL = 1310nm 50 50 50 50 UL UL UL 50 50 50 50 50 50 50 50 Figure 4-11. Simplex transmission between a BMU and four FOR units The second example, shown in Figure 4-11, illustrates a BMU and four FOR units connected via optical splitters in a star configuration. Downlink and uplink wavelength is 1310nm. The optical power loss for an optical 50/50 splitter is 3dB. Additional connectors add a loss of 0.5dB each. Due to the power sharing, up to approximately four slave nodes (FOR) can be connected to a master FON unit (BMU). For additional slave nodes, another FON unit has to be inserted in the BMU. The optical splitters are usually included in the FOU located in the BMU. Figure 4-11 shows, schematically, these parts outside the BMU cabinet. 4 - 12 Rev. P1A9-Draft 2004-11 VM100 56/EN – User’s Manual Powerwave Fiber Optics Duplex Transmission This section contains two examples of full-duplex transmission over fiber. RMU FOR BTS DL DL = 1550nm UL = 1310nm UL DX O DX O Figure 4-12. Duplex transmission between an RMU and a FOR unit The first example, shown in Figure 4-12, illustrates the same repeater configuration as in the previous section, but now with full-duplex over one fiber achieved by using an optical WDM (DX O) in each repeater. The downlink wavelength is 1550nm, the uplink wavelength is 1310nm. The power loss for an optical WDM is 1dB. Additional connectors add the loss by 0.5dB each. The WDMs are included in the FOUs. BMU FOR FOR FOR BTS UL 1310nm UL 1308nm DL 1550nm DX O DX O DX O 30 70 50 50 UL 1312nm DX O Figure 4-13. Duplex transmission between a BMU and three FOR units The second example, shown in Figure 4-13, illustrates a BMU and three FOR units interconnected via optical splitters in a chain configuration. Full-duplex over one fiber is achieved by using an optical WDM (DX O) in each repeater node. The downlink wavelength is 1550nm, the uplink wavelengths are 1308nm, 1310nm, and 1312nm from the three slave nodes (FOR). VM100 56/EN – User’s Manual Rev. P1A9-Draft 2004-11 4 - 13 Fiber Optics Powerwave The optical power loss for an optical 30/70 percent splitter is 5.2dB/1.5dB, for a 50/50 percent splitter 3dB. The power loss for an optical WDM is 1dB. Additional connectors add the loss by 0.5dB each. Due to the power sharing, up to approximately four slave nodes (FOR) can be connected to a master FON unit (BMU). For additional slave nodes, another FON unit has to be inserted in the BMU. The optical WDMs and splitters are usually included in the FOU located in the BMU. Figure 4-13 shows, schematically, these parts outside the BMU cabinet. 4 - 14 Rev. P1A9-Draft 2004-11 VM100 56/EN – User’s Manual Powerwave Fiber Optics 5. IP Over Fiber IP (Internet Protocol) network is the latest Powerwave network type with UDP/IP protocol and many features, such as wire or fiber connection, PPP, routing capabilities for many sub networks, etc. IP network communication includes communication between network nodes as well as communication between gateway nodes, for instance FON units, and an O&M software. Communication can be initiated either by an O&M software or a network node. When initiated by an O&M software, an operator connects to the network and logs on to the desired node. An OMS station can also initiate scheduled communication that automatically connects to the network and logs on to a node. A network node initiates communication when an alarm is to be transferred, normally to an OMS station. It also initiates communication if callback is required in a logon session. All operation and maintenance of repeaters and remote hubs are carried out via an O&M software connected to a network. There are two network types that can be used for this purpose, IP network and R2R network. This chapter describes IP networks only and is focused on fiber networks. IP networks over wire and R2R networks are described in the VM100 01/EN, OMOnline, User’s Manual. This manual also contains further information about IP networks, IP address planning, and network configuration. This chapter is divided into the following main parts: • • • • • • VM100 56/EN – User’s Manual Terminology for IP networks, page 5-2. Hardware and software requirements for IP networks, page 5-3. Fiber optic network characteristics, page 5-4. Node units in IP networks, page 5-5. Net interfaces of the FON unit, page 5-6. An example of a network, page 5-7. Rev. P1A9-Draft 2004-11 5-1 Powerwave Fiber Optics IP Network Terminology In the descriptions of the IP network the terminology in the following table is used. Network type Protocol Network name Link name Link media Link interface IP IP W-net W-link Wire WLI F-net F-link Fiber FLI Abbreviations IP W-net F-net W-link F-link WLI FLI Internet Protocol. Wire network. Fiber network. Wire link. Fiber link. Wire Link Interface. Fiber Link Interface. Other abbreviations used in this manual are found in the Abbreviations section in the beginning of this manual. Net and Link The following two figures show what a net means and what a link means in this manual. Figure 5-1 shows a W-net or F-net with WLI or FLI interface respectively. FON FON FON FON Figure 5-1. W-net or F-net Figure 5-2 shows a W-link or F-link with WLI or FLI interface respectively. Figure 5-2. W-link or F-link 5-2 Rev. P1A9-Draft 2004-11 VM100 56/EN – User’s Manual Powerwave Fiber Optics Requirements To be able to use an IP network, the FON hardware and software stated below is required. Hardware and software that does not meet the requirements below can be upgraded. FON hardware FON board K129. FON software FON SA102 05/1 version R1A or higher. O&M software versions An OM-Online, OMT32, or OMS station intended to be used on an IP network requires the following software versions: OM-Online OMT32 OMS VM100 56/EN – User’s Manual SA102 60/1 version R1A or higher. SA102 51/3 version R2A or higher. SA102 54/1 version R2A or higher. Rev. P1A9-Draft 2004-11 5-3 Powerwave Fiber Optics F-Net Characteristics The IP communication signal in an F-net is modulated on a sub carrier below the RF modulated signal. The communication transfer rate is 66Kb per second. FON FON FON F-net can be built up with separate downlink and uplink fibers, multi-drop link communication, and a dedicated master node and slave nodes (M and S respectively in the left figure). FO F-net can also be built up with single fiber and full-duplex transmission, see Figure 5-3. FON FON DX O DX O DX O DX O FON FON 50 50 FON BTS CS DX 50 50 50 50 RCC PSTN Figure 5-3. Single fiber network with five nodes The network shown in Figure 5-3 has optical WDMs (DX O) in each node, which makes it possible to use one downlink wavelength and four different uplink wavelengths in the same fiber. An F-net contains one master node (the left FON unit in Figure 5-3) and it can contain up to approximately four slave nodes (the right FON units) due to the signal power sharing in the optical splitters. In Figure 5-3 there are three 50/50 percent splitters that reduce the signal power to each of the four slave nodes to 25% of the initial signal power. In Figure 5-3, the master node is a gateway by means of an RCC. It can communicate with an O&M software via modem. The left FON node (CS) only shall be configured with Control Station Capability and thus be the master unit. None of the other FON nodes are allowed to have the Control Station Capability because it is a master/slave network. Only one node is allowed to speak at the same time. Control Station Capability is described in the VM100 01/EN, OM-Online, User’s Manual. 5-4 Rev. P1A9-Draft 2004-11 VM100 56/EN – User’s Manual Powerwave Fiber Optics Node Units This section describes an example of node units used for communication between an O&M software and the nodes in a network. A PC workstation loaded with the O&M software and configured with a modem can be connected to all nodes that have an RCC (or RCU) and communicate with other units in connected W-nets and F-nets. Figure 5-4 shows an O&M workstation connected to an F-net, which is also connected to two W-nets. RF RF BTS RF BSC/CU RF RF BSC/CU BSC/CU RF RF BSC/CU BSC/CU FON FON FON FOR PSTN RCC BMU RF RF BSC/CU FON FOR Figure 5-4. O&M workstation connected to an F/W-net The fibers between the BMU and the FOR units are used for both RF transmission and network communication. An internal backbone W-net in the BMU interconnects the FON units. The two FOR units are also included in two W-nets together with two additional repeaters in each of these W-nets. The O&M workstation in Figure 5-4 can communicate with any of the seven units (one BMU and six repeaters) included in the F-nets and W-nets. VM100 56/EN – User’s Manual Rev. P1A9-Draft 2004-11 5-5 Powerwave Fiber Optics The FON Unit Net Interfaces This section describes the FON unit in networks, one of the most important subunits in repeater networks. The FON unit is here described as a block with network interfaces. The FON board contains all software and protocols required for both W-net and F-net communication, routing included. A sole FON board can be a complete node in an F-net or W-net. Figure 5-5 shows the FON board with the communication interfaces pointed out. The figure shows also some of the most important function blocks on the FON board. The small figure is a simplified block symbol of the FON board. Local Remote RX CPU W-net FON WLI RF SW F-net FLI TX FON FO FO FO Figure 5-5. FON with communication interfaces The CPU unit with loaded software (SW) controls the FON unit including the network communication. The RF block in Figure 5-5 converts electrical signals to optical signals and vice versa. The local port is used for cable connection between the FON unit and an O&M workstation. PPP is used for communication via this port. The remote port is used for remote connection between the FON unit and an O&M workstation via modem. PPP is used for communication via this port. WLI is the communication port for W-net. FON 5-6 FO FON FO FON FO FLI is the communication port for F-net. In Figure 5-5, this part of the FON board is marked to indicate an optical part. The W-net and F-net are interconnected in the FON board, which makes it possible to interconnect several F-nets via a W-net, see the small figure. Rev. P1A9-Draft 2004-11 VM100 56/EN – User’s Manual Powerwave Fiber Optics Network Example An example of a repeater network with FON units is shown in Figure 5-6. BSC BSC BMU/OCM RCC FON WLI BSC FON CU WLI FON FON CU BSC WLI FON BSC FLI FO RCC RCU WLI FON WLI CU RCC WLI FON FON FO FLI FO FLI WLI FON Figure 5-6. Repeater network example This network has a BMU with three FON units as F-net master nodes. Two of which are gateway units. A backbone W-net interconnects the three FON units. The three F-subnets (FLI) are connected to slave FON nodes via optical splitters. These slave FON nodes are connected to compact repeaters (BSC) and standard repeaters (CU) via W-subnets (WLI). In this network there are four gateways connected to an RCU or RCC unit. Further information about IP networks, IP address planning, and network configuration is found in the VM100 01/EN, OM-Online, User’s Manual. VM100 56/EN – User’s Manual Rev. P1A9-Draft 2004-11 5-7 Fiber Optics 5-8 Rev. P1A9-Draft 2004-11 Powerwave VM100 56/EN – User’s Manual Powerwave Fiber Optics 6. Commissioning Read carefully Chapter 1, Safety before commissioning the optical system. See also the safety precautions for the current repeater or hub types. Check all connections made during the installation. Also, ensure that both the mains plugs for repeaters equipped with two power supply units are connected to outlets supplied from the same fuse. To fulfill the IP65 weather protective requirements, ensure that the cable strain relief bushings are properly tightened. Also, ensure that the gaskets at the cable inlets on the cabinet are properly fitted and not damaged. When the installation is checked, commission the optical system as described in the following sections: Equipment required for the commissioning is listed below. This chapter contains commissioning instructions only. If you want to read descriptions of the various functions, see the previous chapters in this manual. Some system configuration examples are found on page 6-6 and the following pages. If you get problems when commissioning the system, please contact your nearest Powerwave representative. Equipment Required To be able to commissioning an optical system you will need the following: • • • • • VM100 56/EN – User’s Manual Optical power meter. Laptop with O&M software and an RS232 serial cable. Spectrum analyzer. Repeater tools. Optical clenaer. Rev. P1A9-Draft 2004-11 6-1 Powerwave Fiber Optics Commissioning the Fiber Optic System Commission the optical transmission system as described in the following instruction. The instruction covers the optical system only and is therefore applicable to all units with optical transmission, for instance BMU, RMU, OCM, FOR, and RH. Figure 6-1 shows a fiber optic system in a BMU and a FOR. These units are also used as examples in the instruction. TX Att. P101 0dBm TX DL DC DPX TX FOR RX FON FON RX TX DPX BMU UL BTS Figure 6-1. Master unit downlink path Master Unit Downlink Path 1. Make sure the BMU is switched off. 2. Measure the downlink input RF signal power (from the BTS) at the FON board connector ’P101’ in Figure 6-1 (or at the OCM/BMU 19" rack) using a spectrum analyzer. The signal power should be between +10dBm and +36dBm. Write down the measured power value. 3. Switch the BMU on and wait until it is in operational mode. 4. Connect the O&M software to the FON board. 5. Measure the optical output power from the FON board (TX) using an optical power meter. If there is only one slave unit on a short distance, choose the low power range. Otherwise, keep the default high power range. If you are in doubt, choose high power and, if needed, change to low power if the received optical power is more than 4dBm at the slave unit. 6. Set the transmitter attenuation (TX Att.) to a value that gives the following optical transmitter an input power of approximately 0dBm. The attenuation is set via the O&M software (FON configuration). PP101 – 20dB – XdB = 0dB 6-2 Meassured RF input signal level at P101 minus 20dB minus XdB attenuation equals 0dB. X is the attenuation set via O&M software. Write down the attenuation set. Rev. P1A9-Draft 2004-11 VM100 56/EN – User’s Manual Powerwave Fiber Optics 7. Measure the optical output power from the FON board (TX) using an optical power meter. Write down the measured power value. It is recommended to set date and time in the FON units, and to assign names to the units for future tracking. Slave Units Continue by performing the following on each slave unit. 8. Make sure the FOR/slave unit is switched off. 9. If two fibers are used, then make sure the uplink and downlink fibers are connected correctly in the FOR/slave unit. The downlink fiber has to be connected to the RX port and the uplink fiber to the TX port of the FON unit, see Figure 6-2. The FOR in the figure is a compact repeater. P102 P103 Beryllium oxide hazard P101 LO HI ANT FON RX TX P115 P109 P104 P106 P110 P130 P105 P111 P112 P108 P113 P114 PSM Fiber optic cables Figure 6-2. Fiber connection in a slave unit VM100 56/EN – User’s Manual Rev. P1A9-Draft 2004-11 6-3 Powerwave Fiber Optics RX DL DPX TX FOR RX FON FON RX TX DPX BMU DC RX Att. UL dBm 0dBm TX Att. RX Att. BTS Figure 6-3. Slave unit downlink path, and uplink path 10. Switch the FOR on and wait until it is in operational mode. 11. Connect an O&M software to the FON board. 12. Measure the optical downlink input power (’RX’ in Figure 6-3). The receiver level is measured via the O&M software (FON status). Write down the measured optical power value. 13. Calculate the optical power loss from the TX port of the master FON board (step 5) to the RX port of the FOR/slave unit (step 12). The loss includes fibers, WDMs, splitters, and connectors used in the current configuration. The calculated optical loss should not exceed 15dB. Write down the calculated optical loss value. 14. Set the receiver attenuation (RX Att.) via the O&M software (FON configuration). An approximate receiver attenuation value can be set according to the calculated loss over the fiber in step 13. Choose value from the table. Optical loss over fiber Receiver attenuation 10dB !10dB 10dB 5dB 15. Move the O&M software from the FON board to the repeater and set the desired repeater bandwidth and downlink gain. 16. Move the O&M software back to the FON board and set the transmitter attenuation (TX Att.) to a calculated value that gives the following optical transmitter an input power of approximately 0dBm. 17. Choose optical transmitter output power range via the O&M software as described in step 6. 6-4 Rev. P1A9-Draft 2004-11 VM100 56/EN – User’s Manual Powerwave Fiber Optics 18. Move the O&M software back to the repeater and set uplink attenuation and gain. Example of downlink and uplink settings are found in the following table. Unit BMU (FON) FOR (FON) BMU (RF) Downlink 5dB att. 10dB att. 60dB gain Uplink 10dB att. 5dB att. 60dB gain The optical system is now ready for operation. A fine-tuning of the system should be done to get the most out of the system. And, the more nodes in the system the more reason to balance and fine-tune it. The following section contains some system configuration examples. VM100 56/EN – User’s Manual Rev. P1A9-Draft 2004-11 6-5 Powerwave Fiber Optics System Configuration Examples Legend: TX level 0dB Fixed values. DL BTS UL 0dB BMU 40dBm 0dB Total UL gain Set values via O&M software. 5dB 0dB Calculated or resultant values. Set and resultant UL gain values in red. 20dB FON BTS initial noise figure –107dBm 0dB 20dB 0dB 20dB RX Att. TX Att. 1.5dBm 1.5dBm BTS initial sensitivity –92.8dBm High, medium, and low values in the example. BTS sensitivity with repeater 14.2dB BTS sensitivity degradiation Number of repeaters 0dB 0dB Fiber/WDM/ splitter loss Fiber/WDM/ splitter loss 1.5dBm FOR 1.5dBm 20dB BTS 20dB TX Att. RX Att. FON FOR Coverage areas 55dB 68dB UL gain DL gain 5dB DPX Repeater noise figure –92.9dBm BTS sensitivity at repeater antenna 33dBm –7dB Total DL gain Limited repeater TX level Figure 6-4. One FOR, low optical loss, low uplink gain and attenuation Figure 6-4 shows a FOR connected with low optical loss, low uplink gain and low uplink attenuation. The BTS sensitivity degradation is high. High total uplink gain and a BTS sensitivty with repeater very close to the BTS sensitivity at the repeater antenna indicates a similar coverage area for the BTS and the FOR. 6-6 Rev. P1A9-Draft 2004-11 VM100 56/EN – User’s Manual Powerwave Fiber Optics Legend: TX level 0dB Fixed values. DL BTS UL 0dB BMU 40dBm 0dB Total UL gain Set values via O&M software. 5dB 0dB Calculated or resultant values. Set and resultant UL gain values in red. 20dB FON BTS initial noise figure –107dBm 0dB 20dB 20dB 20dB RX Att. TX Att. 1.5dBm 1.5dBm BTS initial sensitivity –103.3dBm High, medium, and low values in the example. BTS sensitivity with repeater 3.7dB BTS sensitivity degradiation Number of repeaters 0dB 0dB Fiber/WDM/ splitter loss Fiber/WDM/ splitter loss 1.5dBm FOR 20dB BTS 1.5dBm 20dB TX Att. RX Att. FON FOR Coverage areas 75dB 68dB UL gain DL gain 5dB DPX Repeater noise figure –103.9dBm BTS sensitivity at repeater antenna 33dBm –7dB Total DL gain Limited repeater TX level Figure 6-5. One FOR, low optical loss, medium uplink gain and attenuation Figure 6-5 shows a FOR connected with low optical loss, medium uplink gain and medium uplink attenuation. The BTS sensitivity degradation is low. High total uplink gain and a BTS sensitivty with repeater very close to the BTS sensitivity at the repeater antenna indicates a similar coverage area for the BTS and the FOR. VM100 56/EN – User’s Manual Rev. P1A9-Draft 2004-11 6-7 Powerwave Fiber Optics Legend: TX level 0dB Fixed values. DL BTS UL 0dB BMU 40dBm 0dB Total UL gain Set values via O&M software. 5dB 0dB Calculated or resultant values. Set and resultant UL gain values in red. 20dB FON BTS initial noise figure –107dBm 0dB 20dB 5dB 20dB RX Att. TX Att. –6.5dBm 1.5dBm BTS initial sensitivity –101.3dBm High, medium, and low values in the example. BTS sensitivity with repeater 5.7dB BTS sensitivity degradiation Number of repeaters 10dB 10dB Fiber/WDM/ splitter loss Fiber/WDM/ splitter loss 3.5dBm FOR –8.5dBm 5dB BTS 12dB TX Att. RX Att. FON FOR Coverage areas 65dB 80dB UL gain DL gain 5dB DPX Repeater noise figure –104.7dBm BTS sensitivity at repeater antenna 33dBm –7dB Total DL gain Limited repeater TX level Figure 6-6. One FOR, low optical loss, high uplink gain and attenuation Figure 6-6 shows a FOR connected with low optical loss, high uplink gain and high uplink attenuation. The BTS sensitivity degradation is low. High total uplink gain and a BTS sensitivty with repeater very close to the BTS sensitivity at the repeater antenna indicates a similar coverage area for the BTS and the FOR. 6-8 Rev. P1A9-Draft 2004-11 VM100 56/EN – User’s Manual Powerwave Fiber Optics Legend: TX level 0dB Fixed values. DL BTS UL 0dB BMU 40dBm 0dB Total UL gain Set values via O&M software. 20dB 5dB 0dB Calculated or resultant values. BTS initial noise figure –107dBm 0dB Set and resultant UL gain values in red. 20dB FON 15dB 20dB RX Att. TX Att. –8.5dBm 1.5dBm BTS initial sensitivity –103.5dBm High, medium, and low values in the example. BTS sensitivity with repeater 3.5dB BTS sensitivity degradiation Number of repeaters 10dB 10dB Fiber/WDM/ splitter loss Fiber/WDM/ splitter loss 1.5dBm FOR 10dB 12dB TX Att. BTS –8,5dBm RX Att. FON FOR 80dB 80dB UL gain DL gain 5dB Coverage areas DPX Repeater noise figure –104.1dBm 33dBm BTS sensitivity at repeater antenna Limited repeater TX level –7dB Total DL gain Figure 6-7. One FOR, high optical loss, high uplink gain Figure 6-7 shows a FOR connected with high optical loss, high uplink gain and an uplink attenuation adapted to the optical loss. The BTS sensitivity degradation is low. High total uplink gain and a BTS sensitivty with repeater very close to the BTS sensitivity at the repeater antenna indicates a similar coverage area for the BTS and the FOR. VM100 56/EN – User’s Manual Rev. P1A9-Draft 2004-11 6-9 Powerwave Fiber Optics Legend: TX level 0dB Fixed values. DL BTS UL 0dB BMU 40dBm 0dB Total UL gain Set values via O&M software. 5dB 0dB Calculated or resultant values. Set and resultant UL gain values in red. 20dB FON BTS initial noise figure –107dBm 0dB 20dB 10dB 20dB RX Att. TX Att. 1.5dBm 1.5dBm BTS initial sensitivity –91.7dBm High, medium, and low values in the example. BTS sensitivity with repeater 15.3dB BTS sensitivity degradiation Number of repeaters 0dB 0dB Fiber/WDM/ splitter loss Fiber/WDM/ splitter loss 1.5dBm FOR 1.5dBm 10dB BTS 20dB TX Att. RX Att. FON FOR Coverage areas 55dB 68dB UL gain DL gain 5dB DPX Repeater noise figure –91.8dBm 33dBm BTS sensitivity at repeater antenna Limited repeater TX level –7dB Total DL gain Figure 6-8. Nine FORs, low optical loss, high uplink gain and attenuation Figure 6-8 shows one of nine FORs connected to one of three FON units in the BMU with low optical loss, high uplink gain and high uplink attenuation. The BTS sensitivity degradation is high. High total uplink gain and a BTS sensitivty with repeater very close to the BTS sensitivity at the repeater antenna indicates a similar coverage area for the BTS and the FOR. 6 - 10 Rev. P1A9-Draft 2004-11 VM100 56/EN – User’s Manual Powerwave Fiber Optics Legend: TX level 0dB Fixed values. DL BTS UL 0dB BMU 40dBm 0dB Total UL gain Set values via O&M software. 5dB 0dB Calculated or resultant values. Set and resultant UL gain values in red. 20dB FON BTS initial noise figure –107dBm 0dB 20dB 5dB 20dB RX Att. TX Att. –6dBm 1.5dBm BTS initial sensitivity –93dBm High, medium, and low values in the example. BTS sensitivity with repeater 14dB BTS sensitivity degradiation Number of repeaters 10dB 10dB Fiber/WDM/ splitter loss Fiber/WDM/ splitter loss 4dBm FOR 5dB BTS –8,5dBm 12dB TX Att. RX Att. FON FOR Coverage areas 65dB 80dB UL gain DL gain 5dB DPX Repeater noise figure –93.1dBm BTS sensitivity at repeater antenna 33dBm –7dB Total DL gain Limited repeater TX level Figure 6-9. Nine FORs, high optical loss, high total uplink gain Figure 6-9 shows one of nine FORs connected to one of three FON units in the BMU with high optical loss, high uplink gain and an uplink attenuation adapted to the optical loss. The BTS sensitivity degradation is high. High total uplink gain and a BTS sensitivty with repeater very close to the BTS sensitivity at the repeater antenna indicates a similar coverage area for the BTS and the FOR. VM100 56/EN – User’s Manual Rev. P1A9-Draft 2004-11 6 - 11 Powerwave Fiber Optics Legend: TX level 0dB Fixed values. DL BTS UL 0dB BMU 40dBm –10dB Total UL gain Set values via O&M software. 5dB 0dB Calculated or resultant values. Set and resultant UL gain values in red. 20dB FON BTS initial noise figure –107dBm 0dB 20dB 20dB 20dB RX Att. TX Att. 1.5dBm 1.5dBm BTS initial sensitivity –99.4dBm High, medium, and low values in the example. BTS sensitivity with repeater 7.6dB BTS sensitivity degradiation Number of repeaters 0dB 0dB Fiber/WDM/ splitter loss Fiber/WDM/ splitter loss 1.5dBm FOR 1.5dBm 20dB BTS 20dB TX Att. RX Att. FON FOR Coverage areas 65dB 68dB UL gain DL gain 5dB DPX Repeater noise figure –91.5dBm 33dBm BTS sensitivity at repeater antenna Limited repeater TX level –7dB Total DL gain Figure 6-10. Nine FORs, low optical loss, low total uplink gain Figure 6-10 shows one of nine FORs connected to one of three FON units in the BMU with low optical loss, medium uplink gain and high uplink attenuation. The BTS sensitivity degradation is low. Low total uplink gain decreases the BTS sensitivty with repeater under the BTS sensitivity at the repeater antenna level, indicating a larger coverage area for the BTS than for the FOR. 6 - 12 Rev. P1A9-Draft 2004-11 VM100 56/EN – User’s Manual Powerwave Fiber Optics Legend: TX level 0dB Fixed values. DL BTS UL 0dB BMU 40dBm –10dB Total UL gain Set values via O&M software. 5dB 0dB Calculated or resultant values. Set and resultant UL gain values in red. 20dB FON BTS initial noise figure –107dBm 0dB 20dB 20dB 20dB RX Att. TX Att. –6dBm 1.5dBm BTS initial sensitivity –101.1dBm High, medium, and low values in the example. BTS sensitivity with repeater 5.9dB BTS sensitivity degradiation Number of repeaters 10dB 10dB Fiber/WDM/ splitter loss Fiber/WDM/ splitter loss 4dBm FOR 20dB BTS –8.5dBm 12dB TX Att. RX Att. FON FOR Coverage areas 85dB 80dB UL gain DL gain 5dB DPX Repeater noise figure –93.2dBm 33dBm BTS sensitivity at repeater antenna Limited repeater TX level –7dB Total DL gain Figure 6-11. Nine FORs, high optical loss, low total uplink gain Figure 6-11 shows one of nine FORs connected to one of three FON units in the BMU with high optical loss, and an uplink attenuation adapted to the optical loss. The BTS sensitivity degradation is low. Low total uplink gain decreases the BTS sensitivty with repeater under the BTS sensitivity at the repeater antenna level, indicating a larger coverage area for the BTS than for the FOR. VM100 56/EN – User’s Manual Rev. P1A9-Draft 2004-11 6 - 13 Fiber Optics 6 - 14 Rev. P1A9-Draft 2004-11 Powerwave VM100 56/EN – User’s Manual Powerwave Fiber Optics 7. Passive Devices This chapter describes those passive components that are used to build optical fiber networks with two or more nodes. These devices are: • • • • VM100 56/EN – User’s Manual OSP, Optical splitters, page 7-2. WDM, wavelength division multiplexers, page 7-4. Fiber optic cables, page 7-6. Fiber optic connectors, page 7-9. Rev. P1A9-Draft 2004-11 7-1 Powerwave Fiber Optics OSP, Optical Splitter This section describes those types of optical splitters that are used to build repeater fiber networks. These are variants of three port optical splitters, also called beamsplitters or tee couplers. After the general description, the graphic symbol for the optical splitter, and two examples of splitter usages are found. Figure 7-1. Three port optical splitter The optical splitter is used to split an optical signal in a common fiber port into two or more output fiber ports, and the other way around, that is to combine the signals from two or more input ports into one common port. Optical splitters have to be used to interconnect more than two units in a fiber network. The signal power in the splitter output ports is divided, reducing the signal magnitude in each of the ports. The signal magnitude reduction, or power loss, for the common types of optical splitters for repeater networks are found in the following table. Splitter type Loss 50/50 percent 3dB for each of the ports due to the specification. Typical loss is between 3.2dB and 3.5dB. 5.2dB in the 30% port. 1.5dB in the 70% port. 30/70 percent Additional loss for optical connectors is approximately 0.5dB per connector. The table indicates that a 50/50 percent splitter divides the signal power from the common fiber equally between the output fibers. The splitter has the same loss in the reverse direction. A 30/70 percent splitter divides the signal power from the common fiber in a part with 30% of the common power and another part with 70% of the common power. The splitter has the same loss in the reverse direction. Other types of splitters, such as 90/10, 95/5, and 99/1 percent are not used for repeater networks. 7-2 Rev. P1A9-Draft 2004-11 VM100 56/EN – User’s Manual Powerwave Fiber Optics Graphic Symbol 50 30 50 70 70 30 Figure 7-2. Optical splitter graphic symbol Figure 7-2 shows the following three variants of an optical splitter graphic symbol (according to the EIA/TIA-587): A – A 50/50 percent splitter used for simplex splitting, from the common fiber to the two output fibers. B – A 30/70 percent splitter used for simplex combining, from the two input fibers to the common fiber. C – A 30/70 percent splitter used for duplex splitting/combining between the common fiber and the two input/output fibers. Examples These examples illustrate two networks using optical splitters. 50 50 50 50 50 50 50 50 50 50 50 50 Figure 7-3. Optical splitters in a simplex network Figure 7-3 shows a simplex network using optical splitters. The common fiber is divided into four output parts with 25% of the common power each. 30 70 50 50 Figure 7-4. Optical splitters in a duplex network Figure 7-4 shows a duplex network using optical splitters. The common fiber is divided into three parts with 30 – 35% of the common power each. VM100 56/EN – User’s Manual Rev. P1A9-Draft 2004-11 7-3 Fiber Optics Powerwave WDM, Wavelength Division Multiplexer This section describes those types of optical multipexers that are used to build repeater fiber networks. These are 1310nm and 1550nm WDMs. After the general description, the graphic symbol for the multiplexer, and an example of WDM usage are found. Figure 7-5. Three port WDM, Wavelength Division Multiplexer A WDM is used to split two or more signals of different wavelengths in a common fiber port into two or more output fiber ports, and the other way round, that is to combine signals of different wavelengths from two or more input ports into one common port. The WDM has a very low insertion loss, approximately 1dB. Additional loss for optical connectors is approximately 0.5dB per port. The WDM has two important characteristics, crosstalk and channel separation. • Crosstalk, also called directivity, is the WDM’s ability to separate the demultiplexed channels. Each channel should appear only in the intended output port, not in any other output port. The crosstalk or diversity specification is thus a measurement of the channel isolation. • Channel separation is the WDM’s ability to distinguish different wavelengths. In most WDMs, the wavelengths used has to be widely separated. There are two different ways to use WDMs with 1310 and 1550nm wavelengths. They can be used for single direction dual signal transmission, or for bi-directional transmission, see the following sections. There are WDMs with a channel separation of 2nm, which is shown in the example further ahead in this section. There is also a CWDM type (Coarse WDM) that has a channel separation of 20nm. This type of CWDM with a wider channels spacing can be used for laser emitters that have high spectral width or thermal drift. CWDM systems support transmission distances up to 50km. 7-4 Rev. P1A9-Draft 2004-11 VM100 56/EN – User’s Manual Powerwave Fiber Optics Bi-directional transmission Bi-directional, or duplex, transmission can be used to simultaneously communicate in both directions over the same fiber. Figure 7-6 shows the principle of this communication type. 1310nm TX – 1310nm RX – 1310nm WDM WDM 1550nm RX – 1550nm TX – 1550nm Figure 7-6. Bi-directional transmission Graphic Symbol DX Figure 7-7. WDM graphic symbol Figure 7-7 shows the graphic symbol for the optical WDM, Wavelength Division Multiplexer (according to the EIA/TIA-587). Example This example illustrates a duplex transmission using WDMs and optical splitters. 1550nm 1550nm DX 1308nm 1550nm 1310nm DX O DX O 30 70 50 50 1550nm 1312nm DX O 1308nm 1310nm 1312nm Figure 7-8. Duplex transmission with WDMs Figure 7-8 shows a duplex fiber network with different wavelengths for downlink and uplink. The master unit transmits 1550nm and receives 1308nm, 1310nm, and 1312nm from the three slave units. VM100 56/EN – User’s Manual Rev. P1A9-Draft 2004-11 7-5 Powerwave Fiber Optics Fiber Optic Cables Fiber optic 9/125µm single-mode patch cables for Powerwave repeaters are normally delivered with the system. Recommended backbone cables: Single-mode 9/125µm fiber optic cables. Single-mode 9/125µm fiber optic cables have a very good bandwidth-distance product and a low cable loss, see below. To add cable length, permanent splices are generally used outside buildings while connectors are generally used inside buildings. Permanent slices are described below, connectors are described in the next section. Bandwidth-distance product The bandwidth-distance product (MHz km) for this cable type is higher than 20,000 for both 1310nm and 1550nm. As a comparison, a 50/125µm multi-mode cable has a product between 300 and 1,500. Cable loss The cable loss is found in the following table. Wavelength Loss 1310nm 1550nm 0.35dB per kilometer. 0.20dB per kilometer. Additional loss for optical connectors is approximately 0.5dB per connector. The following diagram illustrates the attenuation differences between some copper coaxial cables and the single-mode fiber cable. 600 RG-58 500 400 dB/km 300 RG-62 RG-11, RG-6U 200 RG-8 100 SM 10 50 100 200 400 700 MHz Figure 7-9. Attenuation for copper coaxial cables and fiber cable Figure 7-9 shows the attenuation for RG-58, RG-62, RG-11, RG-8, RG-6U and singlemode fiber (SM). 7-6 Rev. P1A9-Draft 2004-11 VM100 56/EN – User’s Manual Powerwave Fiber Optics The best of the copper coaxial cables, RG-8, has an attenuation of approximately 100dB/ km at a frequency of 300MHz. This means that only 0.00000001% of the source power remains after a distance of 1km. In a 1550nm single-mode fiber cable of the same length, approximately 95% of the source power remains. This example is applicable for a splice-less cable with no other devices connected. Miscellaneous fiber cable characteristics Minimum bend radius for this cable type is 12mm. The operating temperature range for the most common 9/125µm fiber cabels is –60°C to +85°C. The lowest temperature causes more trouble than the highest temperature. Permanent splices When a fiber cable has to be lengthened, the lowest attenuation and backreflection is obtained by performing a permanent fiber to fiber splice. Connectors can be used for the same purpose, but normally they have higher attenuation and backreflection. Permanent splices are also less expensive. There are two main types of permanent fiber to fiber splices, fusion splice and mechanical splice. Fusion splice Fusion splice implies that the two cleaved fiber ends are butted together and heated until they fuse. To be able to perform this type of splice, a fusion splicer is required. This device has, in addition to an alignment and welding mechanism, also camera or microscope for supervision of the alignment and fuse procedures, and instruments to measure the power through the fiber splice. The attenuation through a correctly performed fusion splice can be as low as 0.05dB. Mechanical splice Mechanical splice implies that the two cleaved fiber ends are joined into a structure, or fixed together with epoxy. To be able to perform this type of splice, a splicer device is required, which is less expensive than a fusion splicer. The easiest way to perform a mechanical splice is to use a thin capillary tube in which the two fiber ends are inserted until they are in contact with each other. This method is called capillary splicing. A mechanical splice may have a slightly higher loss and backreflection than a fusion solice. There is, however, index-matching gel to reduce this loss and backreflection. VM100 56/EN – User’s Manual Rev. P1A9-Draft 2004-11 7-7 Powerwave Fiber Optics Powerwave Patch Cables Powerwave can provide a number of fiber patch cables with connectors for various applications. The following list contains some examples of these fiber cables. Connector A DIN/APC DIN/APC DIN/APC DIN/APC Connector B DIN/APC DIN/APC DIN/APC DIN/APC Length 2m 5m 10m 25m Part # PM403 07/4 PM403 07/2 PM403 07/1 PM403 07/3 DIN/APC DIN/APC DIN/APC DIN/APC FC/APC FC/APC FC/APC FC/APC 2m 5m 10m 25m PM403 01/4 PM403 01/2 PM403 01/1 PM403 01/3 DIN/APC DIN/APC DIN/APC DIN/APC FC/PC FC/PC FC/PC FC/PC 2m 5m 10m 25m PM403 02/4 PM403 02/3 PM403 02/1 PM403 02/2 DIN/APC SC/APC 10m PM403 05/1 DIN/APC SC/PC 10m PM403 04/1 DIN/APC DIN/APC ST ST 2m 10m PM403 03/2 PM403 03/1 FC/APC FC/APC FC/APC FC/APC 2m 10m PM403 09/1 PM403 09/2 FC/PC FC/APC 10m PM403 06/1 As the number of cable lengths and connector combinations grow, please contact your nearest Powerwave representative for information about currently available cables. 7-8 Rev. P1A9-Draft 2004-11 VM100 56/EN – User’s Manual Powerwave Fiber Optics Fiber Optic Connectors There are a number of fiber optic connector types that have different charactersistics, advantages, and disadvantages. There are, however, three basic connector parts that all of these types have in common. These are the connector body, the ferrule, and the coupling device. Figure 7-10 illustrates a typical fiber connector in which these three parts, and other main parts, are pointed out. Fiber cable Bend relief boot Coupling device Alignment sleeve Crimp ferrule Retaining ring Connector body Knurled coupling nut Ferrule Figure 7-10. Typical fiber optic connector Connector body The connector body, or connector housing, holds the ferrule in a center line of the connector. The connector body is generally made of metal or plastic and it can consist of one or many pieces. Ferrule The ferrule holds and align the fiber. The ferrule is, when inserted in the coupler, guided by an alignment sleeve to the right position to meet the connected fiber with a minimum of misalignment. The ferrule end and the fiber end are aligned in the same plane. The fiber face is polished in this plane to minimize power loss. Hackles, lips, fractures, and dirt at this face cause scattering and thus power loss. Ferrules are typically made of metal or ceramic, but can also be made of plastic. Coupling device A coupling device, such as an alignment sleeve, is used instead of male and female connectors common to electric devices. Fiber optic transmitters and receivers, as well as splitters and WDMs, often have the coupling devices built-in and can thus be connected with applicable cable connectors. Connector insertion loss All connectors have an insertion loss of 0.5dB. VM100 56/EN – User’s Manual Rev. P1A9-Draft 2004-11 7-9 Fiber Optics Powerwave Connector Types The most common fiber optic connectors for Powerwave repeaters are briefly described below. DIN These are keyed, spring-loaded connectors with floating sleeves in the couplers. They have threaded coupling nuts. DIN/APC, see APC connectors below. FC The ferrule in a FC connector has face contact (FC) with the joined connector. This type has a threaded coupling nut. FC/APC, see APC connectors below. FC/PC, see PC connectors below. SC The subscription channel (SC) connector is a push-pull connector that gives a click sound when pushed in or pulled out. The ferrule in this connector is decoupled from the cable and the connector body, which means that the ferrule is not affected by cable touches. SC/APC, see APC connectors below. SC/PC, see PC connectors below. ST The straight tip (ST) connector has a spring-loaded bayonet coupling that makes the ferrule not rotate during connection, which means that the insertion loss is consistent. APC connectors All APC connector types are angle polished connectors (APC). In such a connector, the ferrule with the fiber end face is not at straight angle to the fiber center axis (typical deviation for the connectors used is 8° but a deviation of 5° to 15° is common). These connectors have a low backreflection. PC connectors All PC connector types have the ferrule with the fiber end face polished in a certain curve for physical contact (PC). These connectors have a low backreflection. E2000 connectors The E2000 connector has a ceramic ferrule and a moulded plastic body that includes a push-pull latch mechanism. This connector has a spring loaded protective cap over the ferrule that protects the fiber end face from dirt and dust and also protects from laser emission. 7 - 10 Rev. P1A9-Draft 2004-11 VM100 56/EN – User’s Manual Powerwave Fiber Optics Handling Connectors Always have in mind that the fiber area in a fiber optic connector is very small. The diameter of the fiber in a single-mode connector is only 9µm. Compared to a human hair, which is between 50 and 75µm, the fiber diameter is only about a seventh of that diameter. This means that a very small particle on the fiber end face causes trouble. A dust particle, 1µm in size, can suspend indefinitely in the air. On the fiber end face in a connector, this particle can cause a loss of 1dB. A 9µm dust particle can completely put an end to the signal. Dust particles are usually 20µm or larger in diameter. This makes it necessary to cover and clean optical connectors as described below. Covering An optical connector that is not in use must always be covered. If, for example, an unprotected connector is dropped, the fiber end face may be damaged when it reaches the floor. A protection boot is usually provided by the connector manufacturer. It should protect the entire connector, but at least the ferrule. Cleaning Always clean optical connectors immediately before inserting them into the coupling ports. But, wait until the cleaning liquid has get absolutely dry. Use the following cleaning equipment: • • • • Fiber cleaning cloths. Denaturated alcohol. Canned dry air. 30X microscope (for cleaning verification). Clean as follows: 1. Ensure the laser transmitter is off. 2. Clean by using a cleaning device. Or: – Saturate the fiber cleaning cloth with alcohol and clean the entire connector, especially the ferrule with the fiber end face. The cloth must not be dry. – Verify the cleaning result by using the microscope. – Canned air can be used to remove particles from the coupling port. Do not use cleaning liquid in the coupling port. – Never touch the fiber end face. VM100 56/EN – User’s Manual Rev. P1A9-Draft 2004-11 7 - 11 Fiber Optics 7 - 12 Rev. P1A9-Draft 2004-11 Powerwave VM100 56/EN – User’s Manual Powerwave Fiber Optics 8. Troubleshooting This troubleshooting guide is applicable to a BMU connected to a BTS. The BMU is also the master unit in a fiber optic network built-up with FON units, one in the BMU and one in each of the connected repeaters. This guide assumes that no gateway is available in the repeater network, and that alarms are indicated via an alarm relay in the BMU. At the BMU site 1. Inspect the BTS and BMU sites. If a general inspection of the BTS site does not explain the cause of the error, then open the cabinet of the BMU. 2. Check the power in the BMU. This includes the BMU power supply and the fuse in the distribution panel. If a replacement of the PSU does not solve the problem, then check the power distribution cable from the PSU to the FON unit. 3. Check the red FAULT and the green FLI/F2F indicators. If neither the red FAULT indicator in the BMU or the green FLI/F2F indicator are blinking, then the FON unit is not communicating properly with any of the remote repeaters. If there are more than one repeater in the repeater network, then the problem is most likely related to the fiber at the BMU site, or the fiber cable between the BMU and the repeaters. 4. Measure the received uplink 1310nm optical power from the repeater at the patch cables in the BMU. If the measured optical power is higher than –10dBm, then proceed with step 5. If there is no optical power, then check the signal power at the patch panel. 5. Measure the optical uplink power at the RX port of the current FON unit. If the signal power is OK, then proceed with step 6. If there is no power in the RX port, then clean the connectors and measure again. If there is still no power in the RX port, then replace the FOU unit with the passive devices (keep the FON board). The problem is very likely related to a misfunctioning splitter or WDM. 6. Measure the optical downlink transmitting power at the TX port of the same FON unit. If the signal power is not OK, then replace the FON board. VM100 56/EN – User’s Manual Rev. P1A9-Draft 2004-11 8-1 Fiber Optics Powerwave At the repeater site 7. Repeat from step 2 to step 6 but now in the repeater. 8. If there are further repeaters in the network, then measure the optical output power to the next repeater. If there is no power, then the problem most likely refers to the optic splitter. Replace the FOU unit with the passive devices (keep the FON board). A misfunctioning splitter can also be the cause of lost repeaters between the BMU and the current site. 9. As soon as the optical system works, log on to the repeater and read the RF information in the event log. If the error is caused by the RF system, then copy all settings from the current RF unit into a new RF unit and replace the RF unit. The quickest way to determine if the RF level is OK in the repeater is to log on to the repeater and check the RSSI values for the BCCH channel. This value should be between –40dBm and –50dBm. If the RSSI value is not between these values and the FON unit works properly, then measure the RF level from the FOU to the repeater DC coupler using a sitemaster, spectrum analyser, or similar. If the loss is 20dB or more, then the LNA amplifier or the DPX filter is misfunctioning. 8-2 Rev. P1A9-Draft 2004-11 VM100 56/EN – User’s Manual Powerwave Fiber Optics Index Index Abbreviations ...................................................................................................... v APC connectors ............................................................................................... 7-10 BATT, green LED ............................................................................................. Beamsplitter ..................................................................................................... BOOT, red LED ................................................................................................ 3-7 7-2 3-7 Capillary splicing .............................................................................................. CHARGE, yellow LED ....................................................................................... Commissioning ................................................................................................. 7-7 3-7 6-1 DATA, blue LED .............................................................................................. 3-7 DIN connectors ............................................................................................... 7-10 E2000 connectors ............................................................................................ 7-10 ESD ................................................................................................................ 1-6 FAULT, red LED .............................................................................................. 3-7 FC connectors ................................................................................................. 7-10 Fiber-Optic Node ............................................................................................... 3-1 FLI ................................................................................................................. 5-2 FLI, green LED ................................................................................................. 3-6 F-link .............................................................................................................. 5-2 F-net ............................................................................................................... 5-2 F-net characteristics ........................................................................................... 5-4 FON ................................................................................................................ 3-1 FON operational control ................................................................................... 3-11 FON unit .......................................................................................................... 5-6 Fusion splice ..................................................................................................... 7-7 Fusion splicer ................................................................................................... 7-7 Graphic symbol, optical splitter ............................................................................ Graphic symbol, WDM ....................................................................................... 7-3 7-5 Introduction ...................................................................................................... IP ................................................................................................................... IP network ........................................................................................................ IP network requirements ..................................................................................... IP terminology .................................................................................................. VM100 56/EN – User’s Manual Rev. P1A9-Draft 2004-11 2-1 5-2 5-1 5-3 5-2 I-1 Index Fiber Optics Powerwave Link ................................................................................................................ 5-2 Mechanical splice ............................................................................................... 7-7 Net and link ...................................................................................................... Node units ........................................................................................................ 5-2 5-5 OPER, green LED .............................................................................................. 3-7 Operational control, FON .................................................................................. 3-11 Optical splitter ................................................................................................... 7-2 Optical splitter graphic symbol ............................................................................. 7-3 OSP ................................................................................................................. 7-2 PC connectors ................................................................................................. 7-10 Port section LOCAL O&M .............................................................................................. 3-9 Ports P101 RF input ............................................................................................... 3-8 P102 RF output ............................................................................................. 3-8 P103 RF low power output .............................................................................. 3-8 P104 Debug ................................................................................................. 3-9 P105 Front LED indicators .............................................................................. 3-9 P106 PC ...................................................................................................... 3-9 P108 Power .................................................................................................. 3-9 P109 Alarm .................................................................................................. 3-9 P110 W-link jumper ..................................................................................... 3-10 P111 WLI .................................................................................................. 3-10 P112 WLI .................................................................................................. 3-10 P113 Batteries ............................................................................................ 3-10 P114 Backup power output ............................................................................ 3-10 P115 Future port ......................................................................................... 3-10 P116 Power .................................................................................................. 3-9 P130 RCC .................................................................................................. 3-10 RX ............................................................................................................. 3-8 TX .............................................................................................................. 3-8 POWER, yellow LED ......................................................................................... 3-7 Questionnaire ................................................................................................... Q-1 R2R ....................................................................................................... 3-4, R2R net ............................................................................................................ R2R terminology ............................................................................................... 5-2 5-2 5-2 Safety .............................................................................................................. beryllium oxide ............................................................................................. electric shock ................................................................................................ hydrogen fluoride .......................................................................................... laser transmitter ............................................................................................ I-2 Rev. P1A9-Draft 2004-11 1-1 1-1 1-1 1-1 1-2 VM100 56/EN – User’s Manual Powerwave Fiber Optics Index lithium battery .............................................................................................. 1-1 polytetrafluoro ethylene ................................................................................. 1-1 PTFE .......................................................................................................... 1-1 SC connectors ................................................................................................. 7-10 Single-Mode Fiber ............................................................................................. 8-1 SLW ...................................................................................................... 3-4, 5-2 ST connectors ................................................................................................. 7-10 Static electricity ................................................................................................. 1-6 Tee coupler Terminology ...................................................................................................... 7-2 ..................................................................................................... 5-2 Wavelength Division Multiplexer ......................................................................... WDM graphic symbol ........................................................................................ WLI ....................................................................................................... 3-4, WLI, green LED ................................................................................................ W-link ............................................................................................................. W-net ..................................................................................................... 3-4, VM100 56/EN – User’s Manual Rev. P1A9-Draft 2004-11 7-4 7-5 5-2 3-7 5-2 5-2 I-3 Index Fiber Optics I-4 Rev. P1A9-Draft 2004-11 Powerwave VM100 56/EN – User’s Manual Powerwave Fiber Optics Questionnaire Questionnaire The aim of this manual is to guide you when installing and operating the Powerwave repeaters, and to answer questions that may turn up. To ensure that we provide appropriate information for these purposes, we would appreciate your views and suggestions on how to improve the manual in this direction. Please, fill out the following questionnaire and send it to us. Have you read entire sections or do you use the manual to look up specific information when needed? Read entire sections Look up specific information Comments: ___________________________________________________________ _____________________________________________________________________ _____________________________________________________________________ Do you think the information is easy to find and understand? Yes No Comments: ___________________________________________________________ _____________________________________________________________________ _____________________________________________________________________ Do you find any function of the Powerwave repeater hard to understand, a function which should be subjected to more detailed description? Yes No If yes, which one: ______________________________________________________ _____________________________________________________________________ _____________________________________________________________________ Do you have any suggestions on how we can improve this manual? _____________________________________________________________________ _____________________________________________________________________ _____________________________________________________________________ Title (Mr/Ms/Other): ________________________________ Initial:_________________________________________________________ Surname: _________________________________________ Job title:_______________________________________________________ Company: _________________________________________ Address:_______________________________________________________ City: _____________________________________________ Country: _______________________ Phone:_________________________ Thanks for your kind help. It's very valuable to us. VM100 56/EN – User’s Manual Rev. P1A9-Draft 2004-11 Q-1 Questionnaire Powerwave Fiber Optics POSTAGE STAMP Powerwave Technologies Sweden AB Customer Care SE-187 80 Täby Sweden If you prefer to send by mail, fold here and tape. No envelope required. If you prefer to send by fax, use this number: Q-2 Rev. P1A9-Draft 2004-11 +46 8 540 824 85 VM100 56/EN – User’s Manual
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.4 Linearized : No Create Date : 2005:04:01 18:57:52Z Modify Date : 2005:04:12 09:19:34-07:00 Page Count : 91 Creation Date : 2005:04:01 18:57:52Z Mod Date : 2005:04:12 09:19:34-07:00 Producer : Acrobat Distiller 5.0.5 (Windows) Author : jdale Metadata Date : 2005:04:12 09:19:34-07:00 Creator : jdale Title : VM10056-EN_Rev_P1A9_Draft.pdfEXIF Metadata provided by EXIF.tools