Proxim Wireless PROXMB82 802.11A/B/G/N MPCI MODULE User Manual Hardware Installation Guide

Proxim Wireless Corporation 802.11A/B/G/N MPCI MODULE Hardware Installation Guide

users manual-2

Download: Proxim Wireless PROXMB82 802.11A/B/G/N MPCI MODULE User Manual Hardware Installation Guide
Mirror Download [FCC.gov]Proxim Wireless PROXMB82 802.11A/B/G/N MPCI MODULE User Manual Hardware Installation Guide
Document ID2287349
Application IDakM0e47EBQVzh7qDavL5DA==
Document Descriptionusers manual-2
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize259.29kB (3241165 bits)
Date Submitted2014-06-05 00:00:00
Date Available2014-09-24 00:00:00
Creation Date2014-06-06 09:54:57
Producing SoftwareGPL Ghostscript 8.15
Document Lastmod2014-06-06 09:54:57
Document TitleHardware Installation Guide.pdf
Document CreatorAdobe Acrobat 11.0.7
Document Author: CHsieh

8000 Series - Hardware Overview and Installation
3.4 MP-8160-CPE-A100
This section provides the hardware overview and installation method for MP-8160-CPE.
3.4.1 Hardware Overview
Figure 3-34 MP-8160-CPE
A detailed description about the various components of the device are explained in the following sections.
3.4.1.1 Ethernet Port (PoE IN and Data)
The device comes with auto-sensing 10/100 BASE-T Ethernet port with configurable Tx Modes and Speeds.
The Ethernet port of the device allows the user to connect to the LAN by using Cat5/Cat5e or better Ethernet cable, and also
power ON the device by using the Power over Ethernet (PoE) Injector supplied with the product package.
The device receives 48 VDC via a standard Cat5/Cat5e or better cable connected to the Ethernet port.
Maximum power supplied to the device is 19.2 Watts. The device typically draws 5 Watts.
Recommended Ethernet Cable Specifications
Type
Cat5/5e or better, STP, 24 AWG, UL rated, UV-shielded and outdoor-rated
Impedance
100 ohms
Cable Length 330 feet / 100 meters
: The total length of cabling between the Personal Computer and the device
cannot exceed 100 meters (includes cable from the Personal Computer to
the PoE, and the cable from the PoE to the device. Due to DC power
requirements, the maximum cable length between the PoE Injector and the
device is 75 meters.
: Always use a straight cable from PoE to the device. When you use a 4-pair cross over ethernet cable, the reload
functionality gets activated and forcibly deletes the operating image.
3.4.1.2 Grounding Point
To protect the device against lighting or ESD events, you must ground the device properly. To ensure proper grounding, use
the grounding point situated at the bottom corner of the device and the grounding screw (M4 thread size) provided to attach
a ground wire of at least 12 AWG stranded to the device.
Tsunami ÂŽ 800 and 8000 Series - Hardware Installation Guide
81
8000 Series - Hardware Overview and Installation
3.4.2 Product Package
Each shipment includes the items listed in the following table. Please verify that you have received all the parts in the
shipment prior to installation.
What’s in the Kit
Image
MP-8160-CPE
PoE Injector and Power Cord
WD - EU power cord
Connector Weather Proofing
Kit
Pole Mounting Kit
Grounding Kit
Quick Installation Guide
3.4.3 Installation Procedure
This section describes the steps to install and mount the device.
: The device must be installed by a trained professional who is familiar with radio frequency planning and
regulatory limits.
Perform the following steps to install and mount the device.
Step 1: Plan for Installation
There are several planning factors to be considered before installing the device. In addition to selecting the installation site,
you should do the following:
Tsunami ÂŽ 800 and 8000 Series - Hardware Installation Guide
82
8000 Series - Hardware Overview and Installation
Calculate:
Required RSL and fade margin to achieve link availability objectives. For more details on how to calculate RSL and fade
margin, please refer to the ‘Antenna Installation Guide’ and ‘Proxim Link Calculator’ that are available on the support
site at
Required path availability
Anticipated multi-path reflection points
Determine:
System Frequency Plan
Required transmission line types (like cable, waveguides) and lengths
Plan for:
Device’s continuous power consumption needs
Lightning protection and system grounding
Hardware mounting
Cable installation including egress
Pre-testing equipment (back-to-back test procedure)
Step 2: Choose a Location
To make optimal use of the device, you must find a suitable location to install the hardware. Proxim recommends you do a site
survey, observing the following requirements, before mounting the hardware.
The location must allow easy disconnection of power to the radio, if necessary.
Ensure free flow of air around the hardware.
The radio device must be kept away from vibration and excessive heat.
The installation must conform to local regulations at all times.
Step 3: Gather Required Tools
You should have the following tools available before installing the device:
Cross-tip screwdrivers
Large blade standard screwdriver
Spanner 13
Wire crimpers (if using connectors that are not pre-made)
Step 4: Unpack the Product Package
Unpack the device and its accessories from the shipping box.
Please make a note of the Ethernet addresses, MAC addresses and the serial number. These addresses may be used
when configuring the device. Note that the serial number helps you to seek support from the Proxim’s Customer
support team.
Step 5: Pole Mount the Device
1. To pole-mount the device to a 1 inch diameter pole, place the mounting bracket with its small V-Groove facing the
pole.
2. To pole-mount the device to a 2.5 inch diameter pole, place the mounting bracket with its large V-Groove facing the
pole.
3. Place the device with its rear side facing the pole, and screw the M8x80mm long screws along with the spring and
plain washers through the mounting bracket into the mounting holes of the device and tighten it to torque of 11
N.m/100 in-lbs.
Tsunami ÂŽ 800 and 8000 Series - Hardware Installation Guide
83
8000 Series - Hardware Overview and Installation
Figure 3-35 Pole-Mounting
Step 6: Weatherproof RJ45 Connectors
The following steps explain how to weatherproof the RJ45 connector:
1. Use a straight-through cable (Cat5/5e or better) with one end bare.
2. Connect the crimped RJ45 connector end of the cable into the RJ45 Ethernet port inside the enclosure. The cable
connector should latch into the Ethernet port.
3. Slide the Flat Washer (A) into the Connector Body (B) to make it waterproof and onto the bare end of the cable. Next,
fasten the Connector Body into the Ethernet connector hole on the device.
4. Slide the tube-shaped Compression Washer (C) into the Compression Ring (D) and onto the cable from the bare end,
and insert into the fixed Connector Body.
5. Slide the Sealing Nut (E) over the bare end of the cable and fasten it on the fixed Connector Body.
6. Crimp the bare end of the cable with RJ45 connector and connect it to the LAN+DC port on the PoE Injector.
Figure 3-36 Weatherproofing RJ45 Connectors
Additional Weatherproofing Steps
To add an additional layer of protection to the connectors against the environment, see
Step 7: Plug in the Cables
: Unscrew the sealing cap for installation of the cable.
1. Plug one end of the Cat5/5e cable into the Ethernet port of the device by following the Weatherproofing steps as
explained in Step 5. Connect the other end of the Cat5/5e or better cable to the LAN +DC port on the PoE Injector.
Tsunami ÂŽ 800 and 8000 Series - Hardware Installation Guide
84
8000 Series - Hardware Overview and Installation
: Always use a straight cable from PoE to the device. When you use a 4-pair cross over ethernet cable, the reload
functionality gets activated and forcibly deletes the operating image.
Figure 3-37 Cables Plugged In
2. To connect the device through a hub or a switch to a Personal Computer, connect an Ethernet cable between the
network interface card in the Personal Computer and the hub/switch, and between the hub/switch and the RJ45 LAN
port on the PoE Injector.
3. To connect the device directly to a Personal Computer, connect an Ethernet cable between the network interface
card in the Personal Computer and the RJ45 LAN port on the PoE Injector.
Step 8: Install Surge Protector
Proxim recommends two approved lightning surge protectors to be installed, one near to the device and the other at the
building ingress point.
: To buy a suitable Surge Protector, place an order separately with your distributor.
Perform the following steps to ensure proper surge protection:
1. Mount the surge protector near the outdoor device and use 10 AWG or larger wire to connect the protector’s ground
lug to the appropriate mounting ground point. The outdoor device and co-located surge protector should have a
common grounding point using the shortest possible grounding cable.
2. Mount a second surge protector near the building ingress and use 10 AWG or larger wire to connect the surge
protector’s ground lug to earth ground as shown in the following figure.
Figure 3-38 Surge Protector
Tsunami ÂŽ 800 and 8000 Series - Hardware Installation Guide
85
8000 Series - Hardware Overview and Installation
: Use Outdoor-rated, UV protected, shielded Cat5/Cat5e cable for the following.
3. Connect an RJ45 terminated cable between the indoor equipment and to the port on the surge protector at the
building ingress.
4. Connect a short RJ45 terminated cable between the outdoor equipment and the port on the co-located surge
protector.
5. Connect an RJ45 terminated cable between the two surge protectors on their remaining ports.
: Ensure to loop the cable before entering the premise to prevent water ingress.
Step 9: Ground the Device
To ensure proper grounding, use the grounding point situated at the bottom corner of the device and the grounding screw
provided to attach a ground wire of at least 12 AWG stranded to the device. It is important that the following grounding
guidelines are followed to protect the device against lighting or ESD events:
1. Connect one end of the grounding cable to the device and the other end to the closest earthing system point at the
installation.
2. Cut any extra ground wire length when finished connecting it to the single point earth ground.
3. Avoid sharp bends and never loop or coil up the ground wire, always connect it straight to ground.
4. A good earth ground impedance is less than 1.0 ohm.
5. Make sure all connections are fastened securely and are tight.
6. Never install during a storm and always follow your local safety codes.
Connect the grounding wire, which is supplied with the product package, to the grounding lug:
Figure 3-39 Ground the Device
Step 10: Power ON the Device
Plug in the power cord into a power outlet after having connected the PoE Injector and the device using Cat5/5e cable. There
is no ON/OFF switch on the device. To disconnect power, unplug the RJ45 connector from the LAN+DC port on the PoE
injector.
Step 11: View LEDs
When the device is powered on, it performs startup diagnostics. When startup is complete, the LEDs show the device’s
operational state. The LEDs are available at the device’s Ethernet connector inside the enclosure. You can see the LED through
the Ethernet connector. The LEDs will not be visible if the RJ45 connector is weatherproofed.
Tsunami ÂŽ 800 and 8000 Series - Hardware Installation Guide
86
8000 Series - Hardware Overview and Installation
Figure 3-40 LED Indicators
The following table describes the status of LED:
LED State
Ethernet Interface
Power/Ethernet LED
Wireless LED
Off
No Power
Radio is not present or failed to detect
Amber
No Application Image detected
(ScanTool mode)
Power is ON and device detects Reload
signal
Blinking Green
Power is ON and the Ethernet link is
DOWN
Radio is detected but wireless link has
not been established yet
Solid Green
Power is ON and the Ethernet link is UP
Radio is detected and wireless link has
been established
Tsunami ÂŽ 800 and 8000 Series - Hardware Installation Guide
87
8000 Series - Hardware Overview and Installation
3.5 MP-8150-SUR-100 / QB-8150-LNK-100
This section provides the hardware overview and installation method for the following product(s):
MP-8150-SUR-100
QB-8150-LNK-100
3.5.1 Hardware Overview
Figure 3-41 MP-8150-SUR-100 / QB-8150-EPR-100
A detailed description about the various components of the device are explained in the following sections.
3.5.1.1 Gigabit Ethernet Port
The device comes with one auto-sensing 10/100/1000 BASE-T Ethernet port with configurable Tx Modes and speeds.
The Gigabit Ethernet port (PoE IN and Data) of the device allows the user to connect to the LAN by using Cat5e/Cat6 Ethernet
cable, and also power ON the device by using the Power over Ethernet (PoE) Injector supplied with the product package.
The device receives 48 VDC via a a standard Cat5e/Cat6 cable connected between the PoE and the device.
Maximum power supplied to the device is 32 Watts and the device typically draws 6 Watts.
Above 0° Celsius internal temperature, the device does not regulate its temperature, so the power drawn is generally lower in
this temperature range. When the internal temperature gets close to the limits, the device starts to heat itself and the power
draw increases. Powering the device when it is cold, triggers a special self-heat mode where the device is inoperable until the
internal temperature is above -20° Celsius. This is signaled by a solid yellow LED on the Ethernet connector. Once the internal
temperature is above -20° Celsius, the device boots normally.
Recommended Ethernet Cable Specifications
Type
Cat5e/Cat6, STP, 24 AWG, UL rated, UV-shielded and outdoor-rated
Impedance
100 ohms
Cable Length 330 feet / 100 meters
: The total length of cabling between the Personal Computer and the device
cannot exceed 100 meters (includes cable from the Personal Computer to
the PoE, and the cable from the PoE to the device). Due to DC power
requirements, the maximum cable length between the PoE Injector and the
device is 75 meters.
: Always use a straight cable from PoE to the device. When you use a 4-pair cross over ethernet cable, the reload
functionality gets activated and forcibly deletes the operating image.
Tsunami ÂŽ 800 and 8000 Series - Hardware Installation Guide
88
8000 Series - Hardware Overview and Installation
3.5.1.2 Serial Port
The Serial Port is used for debugging and management, and Audible Antenna Alignment through Command Line Interface
(CLI).
The serial connection is established with an RJ11 to DB9 connector (also referred to as a “dongle”) by connecting the RJ11
end of the dongle connector to the device and the other end to your Personal Computer.
Figure 3-42 Serial Components
The pin assignments for DB9 connector are as follows:
D-Shell
RJ11
NC
NC
1+3+5
NC
NC
NC
: The pin6 on RJ11 connector is used as input for 12V DC IN for diagnostic purpose. Supplying power on this pin, when
the device is powered by POE injector, might damage the device.
3.5.1.3 Grounding Point
To protect the device against lighting or ESD events, you must ground the device properly. To ensure proper grounding, use
either of the ground points that are situated at the bottom corner of the device and the grounding screw (#8-32 thread size)
provided to attach a ground wire of at least 10 AWG stranded to the device.
Tsunami ÂŽ 800 and 8000 Series - Hardware Installation Guide
89
8000 Series - Hardware Overview and Installation
3.5.2 Product Package
Each shipment includes the items listed in the following table. Please verify that you have received all the parts in the
shipment, prior to installation.
What’s in the Kit
Image
MP-8150-SUR-100/
QB-8150-EPR-100
PoE Injector with Country
specific Power Cord
WD - US, UK and EU power cords
US - US power cord
EU - UK and EU power cords
RJ11 to DB9 Serial Connector
Connector Weather Proofing
Kit
EMI Toroid
Grounding Kit
Quick Installation Guide
Tsunami ÂŽ 800 and 8000 Series - Hardware Installation Guide
90
8000 Series - Hardware Overview and Installation
What’s in the Kit
Image
Mounting Kit and Hardware
The mounting kit includes the following:
Mounting clamp for wall/pole
Extension arm
Mounting plate to enclosure
Mounting clamp for pole mounting
The following table lists the items included with the mounting kit:
Quantity
Description
6 each
Plain washer #5/16
2 each
Hex Cap Screw NC 5/16-18 x 35
2 each
Nut NC 5/16-18
4 each
Helical Spring Lock Washer #1/4
4 each
Helical Spring Lock Washer #5/16
2 each
Hex Cap Screw NC 5/16-18 x 80
4 each
68764, Screw, Machine, Pan,
Philips, 1/4"-20, 5/8"L
Image
: QB-8150-LNK-100 contains two sets of all the above accessories.
3.5.3 Installation Procedure
This section describes the steps to install and mount the device(s).
: The device must be installed by a trained professional who is familiar with radio frequency planning and
the regulatory limits.
Tsunami ÂŽ 800 and 8000 Series - Hardware Installation Guide
91
8000 Series - Hardware Overview and Installation
Perform the following steps to install and mount the device.
Step 1: Plan for Installation
There are several planning factors to be considered before installing the device. In addition to selecting the installation site,
you should do the following:
Calculate:
Required RSL and fade margin to achieve link availability objectives. For more details on how to calculate RSL and fade
margin, please refer to the ‘Antenna Installation Guide’ and ‘Proxim Link Calculator’ that are available on the support
site at
Required path availability
Anticipated multi-path reflection points
Determine:
System frequency plan
Required antenna mounting height to obtain proper path clearance
Required transmission line types (like cable, waveguides) and lengths
Plan for:
Device’s continuous power consumption needs
Lightning protection and system grounding
Hardware mounting
Cable installation including egress
Pre-testing equipment (back-to-back test procedure)
Step 2: Choose a Location
To make optimal use of the device, you must find a suitable location to install the hardware. The range of the radio device
largely depends upon the position of the antenna. Proxim recommends you do a site survey, observing the following
requirements, before mounting the hardware.
The location must allow easy disconnection of power to the radio, if necessary.
Ensure free flow of air around the hardware.
The radio device must be kept away from vibration and excessive heat.
The installation must conform to local regulations at all times.
The devices are designed to directly mount to a pole. Using the supplied brackets and hardware, you can mount them to a
1.25 inch to 3-inch pole (outside diameter). Longer bolts (not supplied) are required for mounting the device to a larger
diameter pole. By using just one of the pole mounting brackets, you can mount the device to a wall or other flat surface.
Step 3: Gather Required Tools
You should have the following tools available before installing the device:
Cross-tip screwdrivers
Small blade standard screwdriver
Large blade standard screwdriver
Wire crimpers (if using connectors that are not pre-made)
Adjustable 6” wrench
Weatherproofing material for sealing external connectors (such as butyl tape)
Straight-through UV-protected STP-rated Cat5e/Cat6 Ethernet cable for connecting to PC, or cable for connecting to a
hub or a switch.
Tsunami ÂŽ 800 and 8000 Series - Hardware Installation Guide
92
8000 Series - Hardware Overview and Installation
Step 4: Unpack the Product Package
1. Unpack the device and its accessories from the shipping box.
2. Please make a note of the Ethernet addresses, MAC addresses and the serial number. These addresses may be used
when configuring the device. Note that the serial number helps you to seek support from the Proxim’s Customer
support team.
Step 5: Weatherproofing RJ45 Connectors
The following steps explain how to weatherproof the RJ45 connectors:
1. Use a straight-through cable (Cat5e/Cat6) with one end bare.
2. Connect the crimped RJ45 connector end of the cable into the RJ45 Ethernet port inside the enclosure. The cable
connector should latch into the Ethernet port.
3. Slide the Flat Washer (A) into the Connector Body (B) to make it waterproof and onto the bare end of the cable. Next,
fasten the Connector Body into the Ethernet connector hole on the device.
4. Slide the tube-shaped Compression Washer (C) into the Compression Ring (D) and onto the cable from the bare end,
and insert into the fixed Connector Body.
5. Slide the Sealing Nut (E) over the bare end of the cable and fasten it on the fixed Connector Body.
6. Crimp the bare end of the cable with RJ45 connector and connect it to the PWR LAN-OUT port on the PoE Injector.
7. Open the notch on both sides of the toroid and fix it on Ethernet cable. Then, lock the notch of the Toroid by pressing
it.
: To avoid electro magnetic emissions, please ensure to fix Toroid to the Ethernet cable.
Figure 3-43 Weatherproofing RJ45 Connector
Additional Weatherproofing Steps
To add an additional layer of protection to the connectors against the environment, see
Step 6: Assemble Mounting Hardware
Fix the Mounting Plate (A) by using the provided screws and washers (Torque 9 N.m/75 in-lbs) onto the bottom of the device.
Fix the Extension Arm (B) to the fixed mounting plate with the provided screw, nut and washers. The extension arm gives the
device more possible tilt, letting you adjust for azimuth or elevation over a larger angle. Fix the Mounting Bracket (C) to the
fixed Extension Arm with the provided screw, nut and washers. Tighten the assembled parts (Torque 15 N.m/130 in-lbs). The
last picture in the following figure shows the fully assembled mounting hardware fixed to the device.
Tsunami ÂŽ 800 and 8000 Series - Hardware Installation Guide
93
8000 Series - Hardware Overview and Installation
Figure 3-44 Assemble the Mounting Hardware
: This figure is for illustration only. Device should be mounted in square position with Ethernet/Serial port facing
downward.
Step 7: Mount the Device
1. To pole-mount the device, insert the provided screws through bracket (F). Fasten around the pole to bracket (C) and
secure (Torque 11 N.m/100 in-lbs).
Figure 3-45 Pole Mounting
2. To wall-mount the device, mount the bracket to a wall using 4 screws (not provided).
Figure 3-46 Wall Mounting
Tsunami ÂŽ 800 and 8000 Series - Hardware Installation Guide
94
8000 Series - Hardware Overview and Installation
Step 8: Plug in the Cables
: Unscrew the sealing cap for installation of the cable. Always use a straight cable from PoE to the device. When you
use a 4-pair cross over ethernet cable, the reload functionality gets activated and forcibly deletes the operating image.
1. Plug one end of the straight-through Cat5e/Cat6 cable into the Ethernet Port interface of the device by following the
Weatherproofing steps explained under Step 5. Connect the other end of the cable into the PWR LAN-OUT port on
the PoE Injector.
Figure 3-47 Cable Plugged In
2. Optionally, plug the Serial cable into the serial RJ11 telephone jack inside the enclosure for debugging and
management, and audible antenna alignment.
3. To connect the device through a hub or a switch to a Personal Computer, connect an Ethernet cable between the
network interface card in the Personal Computer and the hub, and between the hub and the RJ45 LAN-IN port on the
PoE Injector.
4. To connect the device directly to a Personal Computer, connect an Ethernet cable between the network interface card
in the Personal Computer and the RJ45 LAN-IN port on the PoE Injector.
Step 9: Install Surge Protector
Proxim recommends two approved lightning surge protectors to be installed, one near to the device and the other at the
building ingress point.
: To buy a suitable Surge Protector, place an order separately with your distributor.
Perform the following steps to ensure proper surge protection:
1. Mount the surge protector near the outdoor device and use 10 AWG or larger wire to connect the protector’s ground
lug to the appropriate mounting ground point. The outdoor device and co-located surge protector should have a
common grounding point by using the shortest possible grounding cable.
2. Mount a second surge protector near the building ingress and use 10 AWG or larger wire to connect the surge
protector’s ground lug to earth ground as shown in the following figure.
Tsunami ÂŽ 800 and 8000 Series - Hardware Installation Guide
95
8000 Series - Hardware Overview and Installation
Figure 3-48 Surge Protector
: Use Outdoor-rated, UV protected, shielded Cat5e/Cat6 cable for the following.
3. Connect an RJ45 terminated cable between the indoor equipment and to the port on the surge protector at the
building ingress.
4. Connect a short RJ45 terminated cable between the outdoor equipment and the port on the co-located surge
protector.
5. Connect an RJ45 terminated cable between the two surge protectors on their remaining ports.
: Ensure to loop the cable before entering the premise to prevent water ingress.
Step 10: Ground the Unit
To ensure proper grounding, use either of the ground points which are situated at the bottom corners of the device and the
grounding screw provided to attach a ground wire of at least 10 AWG stranded to the device. It is important that the
following grounding guidelines are followed to protect the device against lighting or ESD events:
1. Connect one end of the grounding cable to the device as shown in the
earthing system point at the installation.
and the other end to the closest
2. Cut any extra ground wire length when finished connecting it to the single point earth ground.
3. Avoid sharp bends and never loop or coil up the ground wire, always connect it straight to ground.
4. A good earth ground impedance is less than 1.0 ohm.
5. Measure ground impedance at the point where the surge protector ground wire is connected and not at the ground
rod.
6. Connect the surge protector ground wire and equipment ground (both power ground and telecomm ground) to a
single common ground.
7. Make sure all connections are fastened securely and are tight.
8. Never install during a storm and always follow your local safety codes.
Tsunami ÂŽ 800 and 8000 Series - Hardware Installation Guide
96
8000 Series - Hardware Overview and Installation
Figure 3-49 Ground the Device
Step 11: Power ON the Device
Plug in the power cord into a power outlet after having connected the PoE Injector and the device using straight-through
Cat5e/Cat6 cable. There is no ON/OFF switch on the device. To disconnect power, unplug the RJ45 connector from the PWR
LAN-OUT port on the PoE injector.
Step 12: View LEDs
When the device is powered on, it performs startup diagnostics. When startup is complete, the LEDs show the device’s
operational state. The LEDs are available at the device’s Ethernet connector inside the enclosure. You can see the LEDs
through the ethernet connector. The LEDs will not be visible if the RJ45 connector is weatherproofed.
Figure 3-50 View LEDs
The following table states the status of LEDs and the corresponding operational state of the device:
LED State
Yellow
Off
Blinking Green-Fast
Power/Ethernet LED
Wireless LED
Ethernet
Power is ON and the device detects
Reload signal
No Power
Radio is not present or failed to detect
Power is ON and the Ethernet link on
Radio is ON and wireless link has not
Ethernet is DOWN
been established yet
Bootloader detected no image
Not Applicable
Device is self heating (Cold Start)
Blinking Green
(5 times) and turns off
Green
Power is ON and the Ethernet link on
Ethernet is UP
Tsunami ÂŽ 800 and 8000 Series - Hardware Installation Guide
Wireless link has been established
97
8000 Series - Hardware Overview and Installation
3.6 MP-8200-BSU / MP-8200-SUA / MP-8250-SUR / QB-8200-EPA&LNK
/QB-8250-EPR&LNK / MP-8250-BS9 / MP-8250-BS1
This section provides the hardware overview and installation procedure for the following product(s):
MP-8200-BSU
MP-8250-BS9
MP-8250-BS1
MP-8200-SUA
MP-8250-SUR
QB-8200-EPA/LNK
QB-8250-EPR/LNK
3.6.1 Hardware Overview
Figure 3-51 MP-8200-BSU / MP-8200-SUA / QB-8200-EPA
Figure 3-52 MP-8250-SUR / MP-8250-BS9 / MP-8250-BS1 / QB-8250-EPR
A detailed description about the various components of the device are explained in the following sections.
3.6.1.1 Gigabit Ethernet Ports
The device comes with two auto-sensing 10/100/1000 BASE-T Ethernet ports with configurable Tx Modes and Speeds.
Tsunami ÂŽ 800 and 8000 Series - Hardware Installation Guide
98
8000 Series - Hardware Overview and Installation
3.6.1.1.1 a) Ethernet Port 1
The Gigabit Ethernet port 1 (PoE IN and Data) of the device allows the user to connect to the LAN by using Cat5e/Cat6
Ethernet cable, and also power ON the device by using the Power over Ethernet (PoE) Injector supplied with the product
package.
The device receives 48 VDC via a standard Cat5e/Cat6 cable connected between the PoE and the device.
Maximum power supplied to the device is 32 Watts and the device typically draws 12 Watts.
Above 0° Celsius internal temperature, the device need not regulate its temperature, so the power drawn is generally lower in
this temperature range. When the internal temperature gets close to the limits, the device starts to heat itself and the power
draw increases. Powering the device when it is cold, triggers a special self-heat mode where the device is inoperable until the
internal temperature is above -20° Celsius. This is signaled by a solid yellow LED on the Ethernet connector. Once the internal
temperature is above -20° Celsius, the device boots normally.
Recommended Ethernet Cable Specifications
Type
Cat5e/Cat6, STP, 24 AWG, UL rated, UV-shielded and outdoor-rated
Impedance
100 ohms
Cable Length 330 feet / 100 meters
: The total length of cabling between the Personal Computer and the device
cannot exceed 100 meters (includes cable from the Personal Computer to
the PoE, and the cable from the PoE to the device. Due to DC power
requirements, the maximum cable length between the PoE Injector and the
device is 75 meters.
: Always use a straight cable from PoE to the device. When you use a 4-pair cross over ethernet cable, the reload
functionality gets activated and forcibly deletes the operating image.
3.6.1.1.2 b) Ethernet Port 2
The Gigabit Ethernet Port 2 is used for PoE OUT and data. While using this port, the following points should be considered:
48 VDC (15 W average) is present on the second Ethernet port. Make sure the connected device can support this
voltage.
If power from the second Ethernet Port is desired, then Proxim recommends you to use 60W PoE (not supplied).
If a device is connected to the second Ethernet port for data only, then use a PoE Splitter (not supplied).
3.6.1.2 Serial Port
The Serial Port is used for debugging and management, and Audible Antenna Alignment through Command Line Interface
(CLI).
The serial connection is established with an RJ11 to DB9 connector (also referred to as a “dongle”) by connecting the RJ1 end
of the dongle connector to the device and the other end to your Personal Computer.
Tsunami ÂŽ 800 and 8000 Series - Hardware Installation Guide
99
8000 Series - Hardware Overview and Installation
Figure 3-53 Serial Components
The pin assignments for DB9 connector are as follows:
D-Shell
RJ11
NC
NC
1+3+5
NC
NC
NC
: The pin6 on RJ11 connector is used as input for 12V DC IN for diagnostic purpose. Supplying power on this pin, when
the device is powered by POE injector, might damage the device.
3.6.1.3 Antenna Ports
: Applicable only to MP-8200-BSU, MP-8200-SUA and QB-8200-EPA/LNK.
The Antenna Ports A1, A2 and A3 are used to connect external antenna (s). These antenna connectors are of N-Type female
with built-in surge protection.
: Use antenna port A1 for single polarization antennas, and antenna ports A1 and A3 for dual polarization antennas. By
default, A1 and A3 ports are enabled. Enable A2 port, in case you are using 3*3 antennas.
: When using a single polarized or dual polarized antenna, ensure to terminate the unused antenna ports
with
(supplied with the product package). Not doing so may damage the radio
card. To buy an additional N-male 50 Ohm Terminator, place an order separately with your distributor.
Tsunami ÂŽ 800 and 8000 Series - Hardware Installation Guide
100
8000 Series - Hardware Overview and Installation
3.6.1.4 Grounding Points
To protect the device against lighting or ESD events, you must ground the device properly. To ensure proper grounding, use
either of the ground points that are situated at the bottom corner of the device and the grounding screw (#8-32 thread size)
provided to attach a ground wire of at least 10 AWG stranded to the device.
3.6.2 Product Package
Each shipment includes the items listed in the following table. Please verify that you have received all the parts in this
shipment, prior to installation.
What’s in the Kit
MP-8200-BSU/
MP-8250-BS9/
MP-8250-BS1/
MP-8200-SUA/
MP-8250-SUR/
QB-8200-EPA/LNK
QB-8250-EPR/LNK
Image
MP-8200-BSU/SUA
MP-8250-SUR / QB-8250-EPR
QB-8200-EPA
MP-8250-BS9/BS1
PoE Injector with Country specific Power
Cord
WD - US, UK and EU power cords
US and JP* - US power cord
EU - UK and EU power cords
* Not for MP-8250-BS9, MP-8250-BS1
RJ11 to DB9 Serial Connector
Connector Weather Proofing Kit (2 sets)
PoE Surge Arrestor
Grounding Kit
Tsunami ÂŽ 800 and 8000 Series - Hardware Installation Guide
101
8000 Series - Hardware Overview and Installation
What’s in the Kit
Image
N-male 50 Ohm Terminator
Supplied with MP-8200-BSU, MP-8200-SUA and
QB-8200-EPA/LNK devices only
Quick Installation Guide
Mounting Kit and Hardware
The mounting kit includes the following:
Mounting clamp for wall/pole
Extension arm
Mounting plate to enclosure
Mounting clamp for pole mounting
The following table lists the items included with the mounting kit:
Quantity
Description
6 each
Plain washer #5/16
2 each
Hex Cap Screw NC 5/16-18 x 35
2 each
Nut NC 5/16-18
4 each
Helical Spring Lock Washer #1/4
4 each
Helical Spring Lock Washer #5/16
2 each
Hex Cap Screw NC 5/16-18 x 80
4 each
68764, Screw, Machine, Pan,
Philips, 1/4"-20, 5/8"L
Image
: QB-8200-LNK and QB-8250-LNK contains two sets of all the above accessories.
Tsunami ÂŽ 800 and 8000 Series - Hardware Installation Guide
102
8000 Series - Hardware Overview and Installation
3.6.3 Installation Procedure
This section describes the steps to install and mount the device(s).
: Please note that we have taken MP-8200-BSU as an example to explain the steps to install and mount the device.
Please correlate the same with your device.
: The device must be installed by a trained professional who is familiar with radio frequency planning and
regulatory limits.
Perform the following steps to install and mount the device.
Step 1: Plan for Installation
There are several planning factors to be considered before installing the device. In addition to selecting the installation site,
you should do the following:
Calculate:
Required RSL and fade margin to achieve link availability objectives. For more details on how to calculate RSL and fade
margin, please refer to the ‘Tsunami® 800 and 8000 Series - Antenna Installation Guide’ and ‘Proxim Link Calculator’
that are available on the support site at
Required path availability
Anticipated multi-path reflection points
Determine:
System frequency plan
Required antenna mounting height to obtain proper path clearance
Required transmission line types (like cable, waveguides) and lengths
Plan for:
Device’s continuous power consumption needs
Lightning protection and system grounding
Hardware mounting
Cable installation including egress
Pre-testing equipment (back-to-back test procedure)
Step 2: Choose a Location
To make optimal use of the device, you must find a suitable location to install the hardware. The range of the radio device
largely depends upon the position of the antenna. Proxim recommends you do a site survey, observing the following
requirements, before mounting the hardware.
The location must allow easy disconnection of power to the radio, if necessary.
Ensure free flow of air around the hardware.
The radio device must be kept away from vibration and excessive heat.
The installation must conform to local regulations at all times.
The devices are designed to directly mount to a pole. Using the supplied brackets and hardware, you can mount them to a
1.25 inch to 3-inch pole (outside diameter). Longer bolts (not supplied) are required for mounting the device to a larger
diameter pole. Using just one of the pole mounting brackets, you can mount the device to a wall or other flat surface.
Tsunami ÂŽ 800 and 8000 Series - Hardware Installation Guide
103
8000 Series - Hardware Overview and Installation
Step 3: Gather Required Tools
You should have the following tools available before installing the device:
Cross-tip screwdrivers
Small blade standard screwdriver
Large blade standard screwdriver
Wire crimpers (if using connectors that are not pre-made)
Adjustable 6” wrench
Weatherproofing material for sealing external connectors (such as butyl tape)
Straight-through UV-protected STP-rated Cat5e/Cat6 Ethernet cable for connecting to PC, or cable for connecting to a
hub or a switch.
Step 4: Unpack the Product Package
1. Unpack the device and its accessories from the shipping box.
2. Please make a note of the Ethernet addresses, MAC addresses and the serial number. These addresses may be used
when configuring the device. Note that the serial number helps you to seek support from the Proxim’s Customer
support team.
Step 5: Weatherproofing RJ45 Connectors
The following steps explain how to weatherproof the RJ45 connectors:
1. Use a straight-through cable (Cat5e/Cat6) with one end bare.
2. Connect the crimped RJ45 connector end of the cable into the RJ45 Ethernet port inside the enclosure. The cable
connector should latch into the Ethernet port.
3. Slide the Flat Washer (A) into the Connector Body (B) to make it waterproof and onto the bare end of the cable. Next,
fasten the Connector Body into the Ethernet connector hole on the device.
4. Slide the tube-shaped Compression Washer (C) into the Compression Ring (D) and onto the cable from the bare end,
and insert into the fixed Connector Body.
5. Slide the Sealing Nut (E) over the bare end of the cable and fasten it on the fixed Connector Body.
6. Crimp the bare end of the cable with RJ45 connector and connect it to the PWR LAN-OUT port on the PoE Injector.
Figure 3-54 Weatherproofing RJ45 Connector
Additional Weatherproofing Steps
For detailed explanation to weatherproof RJ45 connectors, refer to
For detailed explanation to weatherproof RF connections, refer to
Guide, which is available at
TsunamiÂŽ
800 and 8000 Series Antenna Installation
Step 6: Assemble Mounting Hardware
1. Fix the Mounting Plate (A) by using the provided screws and washers (Torque 9 N.m/75 in-lbs).
Tsunami ÂŽ 800 and 8000 Series - Hardware Installation Guide
104
8000 Series - Hardware Overview and Installation
Mounting Plate
Mounting Plate fixed to
the Device
Fixing Mounting Plate
to the device
2. Fix the Extension Arm (B) to the fixed Mounting Plate with the provided screw, nut and washers. The Extension Arm
gives the device more possible tilt, letting you adjust for azimuth or elevation over a larger angle.
Extension Arm
Mounting Plate fixed to the device
Extension Arm fixed to
Mounting Plate
3. Fix the Mounting Bracket (C) to fixed Extension Arm with the provided screw, nut and washers.
Mounting Bracket
Extension Arm fixed to
Mounting Plate
Mounting Bracket fixed to
Extension Arm
4. Tighten the assembled parts (Torque 15 N.m/130 in-lbs).
The following figure shows the fully assembled mounting hardware fixed to the device.
Tsunami ÂŽ 800 and 8000 Series - Hardware Installation Guide
105
8000 Series - Hardware Overview and Installation
Figure 3-55 Assembled Device
Step 7: Mount the Device
1. To pole-mount the device, insert the provided screws and washers through bracket (F). Fasten around the pole to
bracket (C) and secure (Torque 11 N.m/100 in-lbs).
Figure 3-56 Pole Mounting
2. To wall-mount the device, mount the bracket (C) to a wall by using 4 screws (not supplied), as shown:
Figure 3-57 Wall Mounting
Step 8: Plug in the Cables
: Unscrew the sealing cap for installation of the cable.
1. Plug one end of the straight-through Cat5e/Cat6 cable into the Ethernet Port 1 of the device by following the
Weatherproofing steps explained under Step5. Connect the other end of the cable into the PWR LAN-OUT port on
the PoE Injector.
: Always use a straight cable from PoE to the device. When you use a 4-pair cross over ethernet cable, the reload
functionality gets activated and forcibly deletes the operating image.
Tsunami ÂŽ 800 and 8000 Series - Hardware Installation Guide
106
8000 Series - Hardware Overview and Installation
Figure 3-58 Cable Plugged In
2. Plugging in the second Cat5e/Cat6 cable into the Ethernet Port 2 interface of the device is optional. While using the
second Ethernet Port for PoE OUT and data, the following should be considered:
48 VDC (15 W average) is present on the second Ethernet port. Make sure the connected device can support this
voltage.
If power from the second Ethernet Port is desired, then Proxim recommends to use 60W PoE (not supplied).
If the device is connected to the second Ethernet port for data, then use a PoE Splitter (not supplied)
3. Optionally, connect a RJ11 to DB9 Serial Connector to device’s Serial Port for debugging and management, and
audible antenna alignment.
Figure 3-59 PoE Injector
4. To connect the device through a hub or a switch to a Personal Computer, connect an Ethernet cable between the
network interface card in the Personal Computer and the hub, and between the hub and the RJ45 LAN-IN port on the
PoE Injector.
5. To connect the device directly to a Personal Computer, connect an Ethernet cable between the network interface card
in the Personal Computer and the RJ45 LAN-IN port on the PoE Injector.
Step 9: Connect the Antenna
: Applicable only to MP-8200-BSU, MP-8200-SUA and QB-8200-EPA/LNK.
Connect the antenna to the device by connecting the straight N-male end of the cable to the device antenna port and the
right angle N-male end of the cable at the antenna.
Record which port each antenna polarization is associated with, to ensure that each side matches and aid in
configuration.
Ensure to use antenna port A1 for single polarization antennas, and antenna ports A1 and A3 for dual polarization
antennas.
Tsunami ÂŽ 800 and 8000 Series - Hardware Installation Guide
107
8000 Series - Hardware Overview and Installation
Step 10: Install Surge Protector
Proxim recommends two approved lightning surge protectors to be installed, one near to the device and the other at the
building ingress point.
: For an additional Surge Protector, place an order separately with your distributor.
Perform the following steps to ensure proper surge protection:
1. Mount the provided surge protector near the outdoor device and use 10 AWG or a better gauge wire to connect the
protector’s ground lug to the appropriate mounting ground point. The outdoor device and co-located surge protector
should have a common grounding point using the shortest possible grounding cable.
2. Mount a second surge protector near the building ingress and use 10 AWG or a better gauge wire to connect the
surge protector’s ground lug to earth ground as shown in the figure below.
Figure 3-60 Surge Protector
: Use Outdoor-rated, UV protected, shielded Cat5e/Cat6 cable for the following:
3. Connect an RJ45 terminated cable between the indoor device and to the port on the surge protector at the building
ingress.
4. Connect a short RJ45 terminated cable between the outdoor device and the port on the co-located surge protector.
5. Connect an RJ45 terminated cable between the two surge protectors on their remaining ports.
: Ensure to loop the cable before entering the premise to prevent water ingress.
Tsunami ÂŽ 800 and 8000 Series - Hardware Installation Guide
108
8000 Series - Hardware Overview and Installation
Step 11: Ground the Unit
To ensure proper grounding, use either of the ground points which are situated at the bottom corners of the device and the
grounding screw(#8-32 thread size) provided to attach a ground wire of at least 10 AWG stranded to the device. It is
important that the following ground guidelines are followed during installations to protect the device against lighting or ESD
events:
1. Connect one end of the grounding cable to the device and the other end to the closest earthing system point at the
installation.
2. Cut any extra ground wire length when finished connecting it to the single point earth ground.
3. Avoid sharp bends and never loop or coil up the ground wire, always connect it straight to ground.
4. A good earth ground impedance is less than 1.0 ohm.
5. Measure ground impedance at the point where the protector ground wire is connected and not at the ground rod.
6. Connect the surge protector ground wire and equipment ground (both power ground and telecomm ground) to a
single common ground.
7. Make sure all connections are fastened securely and are tight.
8. Never install during a storm and always follow your local safety codes.
Connect the grounding wire, which is supplied with the product package, to the device as shown below:
Figure 3-61 Ground the Device
Step 12: Power ON the Device
Plug in the power cord into a power outlet after having connected the Power Injector and the radio device by using
straight-through Cat5e/Cat6 cable. There is no ON/OFF switch on the device. To disconnect power, unplug the RJ45
connector from the PWR LAN-OUT port on the power injector.
Step 13: View LEDs
When the device is powered on, it performs startup diagnostics. When startup is complete, the LEDs show the device’s
operational state. The LEDs are available at the device’s Ethernet connector inside the enclosure. You can see the LEDs
through the ethernet connector. The LEDs will not be visible if the RJ45 connector is weatherproofed.
Figure 3-62 View LEDs
Tsunami ÂŽ 800 and 8000 Series - Hardware Installation Guide
109
8000 Series - Hardware Overview and Installation
The following table states the status of LEDs and the corresponding operational state of the device:
LED State
Yellow
Off
Blinking Green-Fast
Blinking Green (5
times) and turns off
Green
LED State
Yellow
Off
Blinking Green-Fast
Blinking Green (5
times) and turns off
Green
Ethernet 1
Power/Ethernet LED
Device is self heating (Cold Start)
No Power
Power is on and the Ethernet link on
Ethernet 1 is down
Bootloader detected no image
Power is on and the Ethernet link on
Ethernet 1 is up
Wireless LED
Power is on and the device detects
Reload signal
Radio is not present or failed to detect
Radio is on and wireless link has not
been established yet
Not Applicable
Wireless link has been established
Ethernet 2
Power/Ethernet LED
Wireless LED
Not Applicable
Not Applicable
No Power
Normal Operation
Power is on and the Ethernet link on
Not Applicable
Ethernet 2 is down
Bootloader detected no image
Not Applicable
Power is on and the Ethernet link on
Ethernet 2 is up
Not Applicable
Step 14: Align the Antennas
Antenna alignment is the process of physically aligning the antenna of the radio receiver and transmitter to have the best
possible link established between them. The antenna alignment process is usually performed during installation and after
major repairs. If you are installing external antennas, refer to the documentation that accompanies the antenna for
installation instructions.
The device has an audible antenna alignment tool that can be activated by plugging in the supplied RJ11 serial dongle. It is
audible upto 30 minutes. The CLI command enables both audible and numerical feedback as the CLI shows the running
Signal-to-Noise Ratio (SNR) values twice a second.
The output from the beeper for antenna alignment consists of short beeps with a variable interval. The interval changes with
the SNR level to assist in correctly aligning the antenna. An increase in signal level is indicated by a shorter interval between
beeps and a reduction in signal level results in beeps longer apart.
The alignment process averages the SNR, which is represented by an average length beep. When a higher SNR is received, the
beep period becomes shorter, dependent upon the difference to the average. A lower SNR results in a longer period between
beeps.
Tsunami ÂŽ 800 and 8000 Series - Hardware Installation Guide
110
8000 Series - Hardware Overview and Installation
Figure 3-63 Beep Interval
When the antenna is aimed, the beep intuitively represents whether the SNR is rising or falling. The higher the SNR rises, the
shorter the period of the beep is heard and the higher the frequency of the beep.
When you change the position of the antenna, SNR averaging settles at the new value and the beeping returns to the
average length so the antenna can again be aimed for rising SNR.
Aiming is complete if moving in any direction results in a falling SNR value (which can be heard as longer periods between
beeps).
The range of the average SNR has been limited to values from 5 to 43; therefore, anything over 43 always results in a
short period between beeps and values below 5 always have a long period.
The Antenna Alignment Display (AAD) CLI output is disabled automatically 30 minutes after it is enabled to remove
the load of extra messages on the wireless interface. The default telnet time-out is 300 seconds (5 minutes).
Antenna Alignment Commands
To enable the antenna alignment display from the CLI prompt, enter the following commands:
: Enables display of the local signal, noise and SNR.
: Enables display of the remote signal, noise and SNR.
: Enables display of local and remote signal, noise and SNR.
: Use a flat blade screw driver to disconnect and pull out the Serial cable from the enclosure after the antenna
alignment is done. After withdrawing the cables, seal the serial port carefully to avoid water seepage.
Tsunami ÂŽ 800 and 8000 Series - Hardware Installation Guide
111
Technical Specifications
This chapter provides information on the following topics:
Device Models
Model
Part
Number
Description
Base Stations
MP-820-BSU-100-WD
901-00133
MP 820 Base Station Unit, 100 Mbps, GPS Sync Ready, 2x2 MIMO, 2 N-Type Connectors WD PoE
MP-820-BSU-100-US
901-00135
MP 820 Base Station Unit, 100 Mbps, GPS Sync Ready, 2x2 MIMO, 2 N-Type Connectors US PoE
MP-820-BSU-100-EU
901-00162
MP 820 Base Station Unit, 100 Mbps, GPS Sync Ready, 2x2 MIMO, 2 N-Type Connectors EU PoE
MP-825-BS3-100-WD
901-00184
MP 820 Base Station Unit, 100 Mbps, GPS Sync Ready, 2x2 MIMO, 15 dBi Integrated
Antenna - WD PoE
MP-825-BS3-100-US
901-00185
MP 820 Base Station Unit, 100 Mbps, GPS Sync Ready, 2x2 MIMO, 15 dBi Integrated
Antenna - US PoE
MP-825-BS3-100-EU
901-00186
MP 820 Base Station Unit, 100 Mbps, GPS Sync Ready, 2x2 MIMO, 15 dBi Integrated
Antenna - EU PoE
MP-8100-BSU-US
76705
MP 8100 Base Station Unit, 300 Mbps, 3x3 MIMO, 3 N-Type Connectors - US PoE
MP-8100-BSU-WD
76708
MP 8100 Base Station Unit, 300 Mbps, 3x3 MIMO, 3 N-Type Connectors - WD PoE
MP-8100-BSU-EU
901-00158
MP 8100 Base Station Unit, 300 Mbps, 3x3 MIMO, 3 N-Type Connectors - EU PoE
MP-8160-BSU-WD
901-00109
MP 8160 Base Station Unit, 300Mbps, 2x2 MIMO, 2 N-Type Connectors - WD PoE
MP-8160-BS9-WD
901-00120
MP 8160 Base Station Unit, 300Mbps, 2x2 MIMO, 16 dBi Integrated 90 degree Sector
Antenna - WD PoE
Tsunami ÂŽ 800 and 8000 Series - Hardware Installation Guide
112
Technical Specifications
MP-8200-BSU-US
901-00118
MP 8200 Base Station Unit, 300 Mbps, 3x3 MIMO, 3 N-Type Connectors - US PoE
MP-8200-BSU-WD
901-00116
MP 8200 Base Station Unit, 300 Mbps, 3x3 MIMO, 3 N-Type Connectors - WD PoE
MP-8200-BSU-JP
901-00148
MP 8200 Base Station Unit, 300 Mbps, 3x3 MIMO, 3 N-Type Connectors - JP PoE
MP-8200-BSU-EU
901-00155
MP 8200 Base Station Unit, 300 Mbps, 3x3 MIMO, 3 N-Type Connectors - EU PoE
MP-8250-BS9-US
901-00119
MP 8250 Base Station Unit, 300 Mbps, 2x2 MIMO, 16 dBi Integrated 90o Sector
Antenna - US PoE
MP-8250-BS9-WD
901-00117
MP 8250 Base Station Unit, 300 Mbps, 2x2 MIMO, 16 dBi Integrated 90o Sector
Antenna - WD PoE
MP-8250-BS9-EU
901-00165
MP 8250 Base Station Unit, 300 Mbps, 2x2 MIMO, 16 dBi Integrated 90o Sector
Antenna - EU PoE
MP-8250-BS1-US
901-00170
MP 8250 Base Station Unit, 300 Mbps, 2x2 MIMO, 23 dBi Integrated 10o Panel
Antenna - US PoE
MP-8250-BS1-WD
901-00171
MP 8250 Base Station Unit, 300 Mbps, 2x2 MIMO, 23 dBi Integrated 10o Panel
Antenna - WD PoE
MP-8250-BS1-EU
901-00172
MP 8250 Base Station Unit, 300 Mbps, 2x2 MIMO, 23 dBi Integrated 10o Panel
Antenna - EU PoE
Subscribers
MP-8100-SUA-US
76706
MP 8100 Subscriber Unit, 300 Mbps, 3x3 MIMO, 3 N-Type Connectors - US PoE
MP-8100-SUA-WD
76709
MP 8100 Subscriber Unit, 300 Mbps, 3x3 MIMO, 3 N-Type Connectors - WD PoE
MP-8100-SUA-EU
901-00160
MP 8100 Subscriber Unit, 300 Mbps, 3x3 MIMO, 3 N-Type Connectors - EU PoE
MP-8150-SUR-US
76707
MP 8150 Subscriber Unit, 300 Mbps, 2x2 MIMO, 23 dBi Integrated Antenna - US PoE
MP-8150-SUR-WD
76710
MP 8150 Subscriber Unit, 300 Mbps, 2x2 MIMO, 23 dBi Integrated Antenna - WD PoE
MP-8150-SUR-EU
901-00159
MP 8150 Subscriber Unit, 300 Mbps, 2x2 MIMO, 23 dBi Integrated Antenna - EU PoE
MP-8150-CPE-100a-US
901-00012
MP 8150 CPE, 100Mbps, 2x2 MIMO, 16 dBi Integrated Antenna - US PoE
MP-8150-CPE-100a-WD
901-00014
MP 8150 CPE, 100Mbps, 2x2 MIMO, 16 dBi Integrated Antenna - WD PoE
MP-8150-CPE-A100
901-00050
MP 8150 CPE, 100Mbps, 2x2 MIMO, 16 dBi Integrated Antenna - WD PoE
MP-8150-SUR-100-US
901-00145
MP 8150 Subscriber Unit, 2x50 Mbps, MIMO 2x2, 21dBi Integrated Antenna - US PoE
MP-8150-SUR-100-WD
901-00146
MP 8150 Subscriber Unit, 2x50 Mbps, MIMO 2x2, 21dBi Integrated Antenna - WD PoE
MP-8150-SUR-100-EU
901-00161
MP 8150 Subscriber Unit, 2x50 Mbps, MIMO 2x2, 21dBi Integrated Antenna - EU PoE
MP-8160-SUA-WD
901-00111
MP 8160 Subscriber Unit, 300 Mbps, 2x2 MIMO, 2 N-Type connectors - WD PoE
MP-8160-CPE-A100-WD
901-00110
MP 8160 CPE, 100Mbps, 2x2 MIMO, 15 dBi Integrated Antenna - WD PoE
MP-826-CPE-50-WD
901-00153
MP 826 Customer Premise Equipment , 50 Mbps, 2x2 MIMO, 15dBi integrated antenna World PoE
MP-8200-SUA-US
901-00123
MP 8200 Subscriber Unit, 300 Mbps, 3x3 MIMO, 3 N-Type Connectors - US PoE
MP-8200-SUA-WD
901-00121
MP 8200 Subscriber Unit, 300 Mbps, 3x3 MIMO, 3 N-Type Connectors - WD PoE
MP-8200-SUA-JP
901-00151
MP 8200 Subscriber Unit, 300 Mbps, 3x3 MIMO, 3 N-Type Connectors - JP PoE
MP-8200-SUA-EU
901-00157
MP 8200 Subscriber Unit, 300 Mbps, 3x3 MIMO, 3 N-Type Connectors - EU PoE
MP-8250-SUR-US
901-00124
MP 8250 Subscriber Unit, 300 Mbps, 2x2 MIMO, 23 dBi, Panel Antenna – US PoE
MP-8250-SUR-WD
901-00122
MP 8250 Subscriber Unit, 300 Mbps, 2x2 MIMO, 23 dBi, Panel Antenna – WD PoE
MP-8250-SUR-JP
901-00152
MP 8250 Subscriber Unit, 300 Mbps, 2x2 MIMO, 23 dBi, Panel Antenna – JP PoE
Tsunami ÂŽ 800 and 8000 Series - Hardware Installation Guide
113
Technical Specifications
MP-8250-SUR-EU
901-00156
MP 8250 Subscriber Unit, 300 Mbps, 2x2 MIMO, 23 dBi, Panel Antenna – EU PoE
MP-820-SUA-50+-WD
901-00134
MP 820 Subscriber Unit, 50 Mbps (Upgradable to 100 Mbps), 2x2 MIMO, 2 N-Type
Connectors - WD PoE
MP-820-SUA-50+-US
901-00136
MP 820 Subscriber Unit, 50 Mbps (Upgradable to 100 Mbps), 2x2 MIMO, 2 N-Type
Connectors - US PoE
MP-820-SUA-50+-EU
901-00163
MP 820 Subscriber Unit, 50 Mbps (Upgradable to 100 Mbps), 2x2 MIMO, 2 N-Type
Connectors - EU PoE
MP-825-SUR-50+-WD
901-00175
MP 825 Subscriber Unit, 50 Mbps (Upgradable to 100 Mbps), 2x2 MIMO, 15 dBi, Panel
Antenna - WD PoE
MP-825-SUR-50+-US
901-00176
MP 825 Subscriber Unit, 50 Mbps (Upgradable to 100 Mbps), 2x2 MIMO, 15 dBi, Panel
Antenna - US PoE
MP-825-SUR-50+-EU
901-00177
MP 825 Subscriber Unit, 50 Mbps (Upgradable to 100 Mbps), 2x2 MIMO, 15 dBi, Panel
Antenna - EU PoE
MP-825-CPE-50-US
901-00137
MP 825 Customer Premise Equipment, 50 Mbps, MIMO 2x2, 15 dBi integrated antenna US PoE
MP-825-CPE-50-WD
901-00138
MP 825 Customer Premise Equipment, 50 Mbps, MIMO 2x2, 15 dBi integrated antenna WD PoE
MP-825-CPE-50-EU
901-00154
MP 825 Customer Premise Equipment, 50 Mbps, MIMO 2x2, 15 dBi integrated antenna EU PoE
MP-825-CPE-100-WD
901-00187
MP 825 Customer Premise Equipment, 100 Mbps, MIMO 2x2, 15 dBi integrated antenna
- WD PoE
MP-825-CPE-100-US
901-00188
MP 825 Customer Premise Equipment, 100 Mbps, MIMO 2x2, 15 dBi integrated antenna
- US PoE
MP-825-CPE-100-EU
901-00189
MP 825 Customer Premise Equipment, 100 Mbps, MIMO 2x2, 15 dBi integrated antenna
- EU PoE
Quick Bridges
QB-8100-EPA-US
76946
QB 8100 End Point A, 300 Mbps, 3x3 MIMO, 3 N-Type Connectors - US PoE
QB-8100-EPA-WD
76947
QB 8100 End Point A, 300 Mbps, 3x3 MIMO, 3 N-Type Connectors - WD PoE
QB-8100-EPA-EU
902-00663
QB 8100 End Point A, 300 Mbps, 3x3 MIMO, 3 N-Type Connectors - EU PoE
QB-8100-LNK-US
77519
QB 8100 Link (A pair of QB-8100-EPA-US devices), 300 Mbps, 3x3 MIMO, 3 N - Type
Connectors - US PoE
QB-8100-LNK-WD
77518
QB 8100 Link (A pair of QB-8100-EPA-WD devices), 300 Mbps, 3x3 MIMO, 3 N - Type
Connectors - WD PoE
QB-8100-LNK-EU
902-00661
QB 8100 Link (A pair of QB-8100-EPA-EU devices), 300 Mbps, 3x3 MIMO, 3 N - Type
Connectors - EU PoE
QB-8150-EPR-US
76821
QB 8150 End Point Ruggedized, 300 Mbps, 2x2 MIMO, 23 dBi Integrated Antenna - US
PoE
QB-8150-EPR-WD
76823
QB 8150 End Point Ruggedized, 300 Mbps, 2x2 MIMO, 23 dBi Integrated Antenna - WD
PoE
QB-8150-EPR-EU
902-00662
QB 8150 End Point Ruggedized, 300 Mbps, 2x2 MIMO, 23 dBi Integrated Antenna - EU
PoE
QB-8150-LNK-US
76822
QB 8150 Link (A pair of QB-8150-EPR-US devices), 300 Mbps, 2x2 MIMO, 23 dBi
Integrated Antenna - US PoE
QB-8150-LNK-WD
76824
QB 8150 Link (A pair of QB-8150-EPR-WD devices), 300 Mbps, 2x2 MIMO, 23 dBi
Integrated Antenna - WD PoE
Tsunami ÂŽ 800 and 8000 Series - Hardware Installation Guide
114
Technical Specifications
QB-8150-LNK-EU
902-00660
QB 8150 Link (A pair of QB-8150-EPR-EU devices), 300 Mbps, 2x2 MIMO, 23 dBi
Integrated Antenna - EU PoE
QB-8150-LNK-12-WD
902-00056
QB 8150 Link (A pair of QB-8150-EPR-12-WD devices), 12 Mbps, 2x2 MIMO, 16 dBi
Integrated Antenna - WD PoE
QB-8150-LNK-50-US
902-00063
QB 8150 Link (A pair of QB-8150-EPR-50-US devices), 50 Mbps, 2x2 MIMO, 16 dBi
Integrated Antenna - US PoE
QB-8150-LNK-50-WD
902-00064
QB 8150 Link (A pair of QB-8150-EPR-50-WD devices), 50 Mbps, 2x2 MIMO, 16 dBi
Integrated Antenna - WD PoE
QB-8150-LNK-100-US
902-00644
QB 8150 Link (A pair of QB-8150-EPR-100-US devices), 2x50 Mbps, MIMO 2x2, 21 dBi
Integrated Antenna - US PoE
QB-8150-LNK-100-WD
902-00645
QB 8150 Link (A pair of QB-8150-EPR-100-WD devices), 2x50 Mbps, MIMO 2x2, 21 dBi
Integrated Antenna - WD PoE
QB-8151-EPR-US
902-00748
QB 8151 End Point Ruggedized, 300 Mbps, 2x2 MIMO, 21 dBi Integrated Antenna - US
PoE
QB-8151-EPR-WD
902-00750
QB 8151 End Point Ruggedized, 300 Mbps, 2x2 MIMO, 21 dBi Integrated Antenna - WD
PoE
QB-8151-LNK-US
902-00749
QB 8151 Link (A pair of QB-8151-EPR-US devices), 300 Mbps, 2x2 MIMO, 21 dBi
Integrated Antenna - US PoE
QB-8151-LNK-WD
902-00751
QB 8151 Link (A pair of QB-8151-EPR-WD devices), 300 Mbps, 2x2 MIMO, 21 dBi
Integrated Antenna - WD PoE
QB-8200-EPA-US
902-00595
QB 8200 End Point, 300 Mbps, 3x3 MIMO, 3 N-Type Connectors - US PoE
QB-8200-EPA-WD
902-00594
QB 8200 End Point, 300 Mbps, 3x3 MIMO, 3 N-Type Connectors - WD PoE
QB-8200-EPA-JP
902-00654
QB 8200 End Point, 300 Mbps, 3x3 MIMO, 3 N-Type Connectors - JP PoE
QB-8200-EPA-EU
902-00668
QB 8200 End Point, 300 Mbps, 3x3 MIMO, 3 N-Type Connectors - EU PoE
QB-8200-LNK-US
902-00599
QB 8200 Link (A pair of QB-8200-EPA-US devices), 300 Mbps, 3x3 MIMO, 3 N - Type
Connectors - US PoE
QB-8200-LNK-WD
902-00598
QB 8200 Link (A pair of QB-8200-EPA-WD devices), 300 Mbps, 3x3 MIMO, 3 N - Type
Connectors - WD PoE
QB-8200-LNK-JP
902-00655
QB 8200 Link (A pair of QB-8200-EPA-JP devices), 300 Mbps, 3x3 MIMO, 3 N - Type
Connectors - JP PoE
QB-8200-LNK-EU
902-00658
QB 8200 Link (A pair of QB-8200-EPA-EU devices), 300 Mbps, 3x3 MIMO, 3 N - Type
Connectors - EU PoE
QB-8250-EPR-US
902-00600
QB 8250 End Point, 300 Mbps, 2x2 MIMO, 23 dBi, Panel Antenna - US PoE
QB-8250-EPR-WD
902-00596
QB 8250 End Point, 300 Mbps, 2x2 MIMO, 23 dBi, Panel Antenna - WD PoE
QB-8250-EPR-JP
902-00656
QB 8250 End Point, 300 Mbps, 2x2 MIMO, 23 dBi, Panel Antenna - JP PoE
QB-8250-EPR-EU
902-00669
QB 8250 End Point, 300 Mbps, 2x2 MIMO, 23 dBi, Panel Antenna - EU PoE
QB-8250-LNK-US
902-00601
QB 8250 Link (A pair of QB-8250-EPR-US devices), 300 Mbps, 2x2 MIMO, 23 dBi, Panel
Antenna - US PoE
QB-8250-LNK-WD
902-00597
QB 8250 Link (A pair of QB-8250-EPR-WD devices), 300 Mbps, 2x2 MIMO, 23 dBi, Panel
Antenna - WD PoE
QB-8250-LNK-JP
902-00657
QB 8250 Link (A pair of QB-8250-EPR-JP devices), 300 Mbps, 2x2 MIMO, 23 dBi, Panel
Antenna - JP PoE
QB-8250-LNK-EU
902-00659
QB 8250 Link (A pair of QB-8250-EPR-EU devices), 300 Mbps, 2x2 MIMO, 23 dBi, Panel
Antenna - EU PoE
Tsunami ÂŽ 800 and 8000 Series - Hardware Installation Guide
115
Technical Specifications
QB-825-EPR-50-US
902-00743
QB 825 End Point, 50 Mbps, 2x2 MIMO, 15 dBi Antenna - US PoE
QB-825-EPR-50-WD
902-00745
QB 825 End Point, 50 Mbps, 2x2 MIMO, 15 dBi Antenna - WD PoE
QB-825-LNK-50-US
902-00744
QB 825 Link (A pair of QB-825-EPR-50-US devices), 50 Mbps, 2x2 MIMO, 15 dBi Antenna
- US PoE
QB-825-LNK-50-WD
902-00746
QB 825 Link (A pair of QB-825-EPR-50-WD devices), 50 Mbps, 2x2 MIMO, 15 dBi
Antenna - WD PoE
QB-825-LNK-50+-WD
902-00637
QB 825 Link (A pair of QB-825-EPR-50+-WD devices), GPS Sync Ready, 50 Mbps
(Upgradable to 100 Mbps), 2x2 MIMO, 15 dBi Antenna - WD PoE
QB-825-LNK-50+-US
902-00638
QB 825 Link (A pair of QB-825-EPR-50+-US devices), GPS Sync Ready, 50 Mbps
(Upgradable to 100 Mbps), 2x2 MIMO, 15 dBi Antenna - US PoE
QB-825-LNK-50+-EU
902-00665
QB 825 Link (A pair of QB-825-EPR-50+-EU devices), GPS Sync Ready, 50 Mbps
(Upgradable to 100 Mbps), 2x2 MIMO, 15 dBi Antenna - EU PoE
Accessories
Part Numbers
Accessories
76590
25m, RJ45 terminated, UV Rated, STP CAT5e cable for outdoor use
76591
50m, RJ45 terminated, UV Rated, STP CAT5e cable for outdoor use
76592
75m, RJ45 terminated, UV Rated, STP CAT5e cable for outdoor use
949-00075
6 ft Super-Low Loss Coaxial Antenna Cable, 0.600”, Standard N-Male to Right Angle N-Male
235-00001
Surge Protector, Gigabit Surge Protector with Shielded RJ45 Connector
76593
Weatherproof Cable Gland Connector
76346
32W Gigabit PoE injector with RJ45 Connector and Reload button
949-00019
4.9 - 6.1 GHz, Dual Polarity, Vertical and Horizontal, 30 dBi Panel Antenna
76955
4.9 - 5.875 GHz, Dual Polarity, Slanted (Âą45Âş) or V/H, 23 dBi Panel Antenna
77067
4.9 - 6.1 GHz, Dual Polarity, Slanted (Âą45Âş), 17 dBi Sector Antenna - 60 degrees
77551
5.1 - 6.1 GHz, Triple Polarization MIMO, Slanted (Âą45Âş) and Vertical, 17 dBi Panel Antenna
949-00012
4.9-5.95GHz, Dual Polarity, Vertical and Horizontal, 14 dBi Sector Antenna- 90 degrees. Mounting kit included.
77552
4.9 - 6.1 GHz, Triple Polarizations MIMO, Slanted (Âą45Âş) and Vertical, 16 dBi Sector Antenna - 90 degrees
949-00011
4.9-6GHz, Dual Polarity, Vertical /Horizontal,16.5 dBi Sector Antenna - 60 degrees. Mounting kit included.
949-00024
5.9-6.425 GHz Dual Polarized Base Station Antenna 90 degrees
949-00025
5.9-6.425 GHz Dual Polarized Base Station Antenna 60 degrees
949-00026
5.7-6.425 GHz Dual Polarized Subscriber Antenna
949-00045
Cable Feed-Through Sealing Cap kits, PACK OF 20 ( MP/QB.11)
125-00003
2-6 GHz High Performance RF Lightning Arrestor, N-Female to N-Male Protected
76409
Outdoor Universal Mounting Kit for TMP.11; TMP.16; TMP8000
Tsunami ÂŽ 800 and 8000 Series - Hardware Installation Guide
116
Technical Specifications
400-00002
PoE Gigabit 48V DC Injector with terminal Jack - 25 pack
949-00027
2.3-2.7 GHz, Dual Polarity, Vertical and Horizontal, 20 dBi Panel Antenna
949-00083
Spare gas capsule for Tsunami 8100 N-Type connector
1087-UMK
Universal Mounting Bracket for Wall Mounting. Refer
210-00046
N Male Terminator 50 Ohm, 0-6 GHz
949-00017
6 ft Super-Low Loss Coaxial Antenna Cable, 0.600”, St-N - Male-Male
Tsunami ÂŽ 800 and 8000 Series - Hardware Installation Guide
117
Technical Specifications
OFDM Modulation Rates
Given below are the OFDM modulation rates for the TsunamiÂŽ 800 and 8000 series products:
Data Rates (Mbps)
5 MHz
10 MHz
20 MHz
40 MHz
Modulation
Full GI-800ns
Full GI-800ns
Full GI-800ns
Short GI-400ns
Full GI-800ns
Longer
Higher
Longer
Higher
Longer
Higher
Longer
Higher
Longer
Higher
Range Throughput Range Throughput Range Throughput Range Throughput Range Throughput
BPSK 1/2
1.6
3.3
3.3
6.5
6.5
13
15
30
13.5
27
QPSK 1/2
3.3
6.5
6.5
13
13
26
30
60
27
54
QPSK 3/4
4.9
9.7
9.7
19.5
19.5
39
45
90
40.5
81
16QAM 1/2
6.5
13
13
26
26
52
60
120
54
108
16QAM 3/4
9.7
19.5
19.5
39
39
78
90
180
81
162
64QAM 2/3
13
26
26
52
52
104
120
240
108
216
64QAM 3/4
14.6
29.3
29.3
58.5
58.5
117
135
270
121.5
243
64QAM 5/6
16.2
32.5
32.5
65
65
130
150
300
135
270
Note: Maximum Packet Size = 1500 Bytes (excluding one VLAN header, Ethernet header and FCS).
Products
Modulation
BPSK 1/2
BPSK 3/4
QPSK 1/2
QPSK 3/4
16QAM 1/2
16QAM 3/4
64QAM 2/3
64QAM 3/4
MP-8100-BSU
MP-8100-SUA
MP-8150-SUR
MP-8150-SUR-100
MP-8150-CPE
MP-8200-BSU
MP-8200-SUA
MP-8250-SUR
MP-8250-BS9
MP-8250-BS1
MP-820-BSU-100
MP-820-SUA-50+
MP-825-SUR-50+
MP-825-BS3-100
MP-825-CPE-50
MP-825-CPE-100
5 MHz
1.5
2.25
4.5
12
13.5
Legacy Data Rates (Mbps)
10 MHz
4.5
12
18
24
27
20 MHz
12
18
24
36
48
54
Wireless Protocol
Category
Wireless Protocol
Specification
WORPÂŽ (Wireless Outdoor Router Protocol)
Tsunami ÂŽ 800 and 8000 Series - Hardware Installation Guide
118
Technical Specifications
Interfaces
Products
Category
Specification
MP-8100-BSU; MP-8100-SUA
MP-8150-SUR; MP-8160-BSU
MP-8160-SUA; MP-8160-BS9
MP-8200-BSU; MP-8200-SUA
MP-8250-SUR; MP-8250-BS9; MP-8250-BS1
QB-8100-EPA/LNK; QB-8150-EPR/LNK
QB-8151-EPR/LNK
QB-8200-EPA/LNK; QB-8250-EPR/LNK
Wired Ethernet
Two auto MDI-X RJ45 Gigabit Ethernet Ports
– Port #1 with PoE IN and Data
– Port #2 with PoE OUT (802.3af pin-out) and Data
Serial Connector
RJ11 port built-in, DB9 Female via a converter included
MP-8150-CPE
MP-8160-CPE-A100
MP-825-CPE-100
MP-825-CPE-50
MP-826-CPE-50
QB-825-EPR/LNK-50
QB-8150-LNK-12/50
Wired Ethernet
One auto MDI-X RJ45 100 Mbps Ethernet Port
Serial Connector *
RS 232 Serial (RJ11 to DB9)
MP-8150-SUR-100
QB-8150-LNK-100
MP-820-BSU-100
MP-820-SUA-50+
MP-825-BS3-100
MP-825-SUR-50+
QB-825-EPR/LNK-50+
Wired Ethernet
One auto MDI-X RJ45 Gigabit Ethernet Port
Serial Connector
RS 232 Serial (RJ11 to DB9)
* Not applicable to MP-8160-CPE-A100, MP-825-CPE-100, MP-825-CPE-50, MP-826-CPE-50 and QB-825-EPR/LNK-50.
Tsunami ÂŽ 800 and 8000 Series - Hardware Installation Guide
119
Technical Specifications
Transmit Power Settings
2.4 and 5 GHz
Products
MP-8100-BSU
MP-8100-SUA
MP-8150-SUR
MP-8150-SUR-100
QB-8100-EPA/LNK
QB-8150-EPR/LNK
QB-8150-LNK-100
QB-8151-EPR/LNK
Stream
Single (or) Dual
Stream
Modulation
Tx Power* for 20/40 MHz (+3/-2dB)
BPSK 1/2
21
QPSK 1/2
21
QPSK 3/4
21
16 QAM 1/2
21
16 QAM 3/4
21
64 QAM 2/3
19
64 QAM 3/4
18
64 QAM 5/6
17
Note:
Output Power Attenuation: 0 – 25 dB, in 1 dB steps
Total EIRP must be calculated based on the antenna gain
* Tx Power indicates the power at the radio ports.
* In case of connectorized devices, the Tx Power at the antenna ports is 1 dB lower than the above tabulated values.
* Tx Power indicates the combined power for two Antenna ports. In order to use third antenna port, add 1.8 dB to the above values.
4.9 - 5.925 GHz
Products
MP-8200-BSU
MP-8250-BS9
MP-8250-BS1
MP-8200-SUA
MP-8250-SUR
QB-8200-EPA/LNK
QB-8250-EPR/LNK
Stream
Single
(or)
Dual
Stream
Modulation
Tx Power* for 5/10/20 MHz (+/-1dB)
Tx Power* for 40 MHz (+/-1dB)
BPSK 1/2
24
22
QPSK 1/2
24
22
QPSK 3/4
23
22
16 QAM 1/2
22
21
16 QAM 3/4
21
20
64 QAM 2/3
20
19
64 QAM 3/4
19
18
64 QAM 5/6
18
17
Note:
Output Power Attenuation: 0 – 25 dB, in 1 dB steps
Total EIRP must be calculated based on the antenna gain
* Tx Power indicates the power at the radio ports.
* In case of connectorized devices, the Tx Power at the antenna ports is 1 dB lower than the above tabulated values.
* Tx Power indicates the combined power for two Antenna ports. In order to use third antenna port, add 1.8 dB to the above values.
Tsunami ÂŽ 800 and 8000 Series - Hardware Installation Guide
120
Technical Specifications
6.4 GHz
Products
Stream
Modulation
Tx Power* for 5/10/20/40 MHz (+/-1dB)
MP-8160-BSU
MP-8160-BS9
MP-8160-SUA
MP-8160-CPE-A100
Single (or)
Dual Stream
BPSK 1/2
25
QPSK 1/2
25
QPSK 3/4
25
16 QAM 1/2
25
16 QAM 3/4
23
64 QAM 2/3
22
64 QAM 3/4
19
64 QAM 5/6
16
Note:
Output Power Attenuation: 0 – 25 dB, in 1 dB steps
Total EIRP must be calculated based on the antenna gain
* Tx Power indicates combined power at the radio ports.
* In case of connectorized devices, the Tx Power at the antenna ports is 1 dB lower than the above tabulated values.
5 GHz
Products
MP-8150-CPE
QB-8150-LNK-12/50
Stream
Single (or)
Dual Stream
Modulation
Tx Power* (dBm) for 20/40 MHz
BPSK 1/2
23
QPSK 1/2
23
QPSK 3/4
23
16 QAM 1/2
23
16 QAM 3/4
22
64 QAM 2/3
21
64 QAM 3/4
20
64 QAM 5/6
19
Note:
Output Power Attenuation: 0 – 23 dB, in 1 dB steps
Output Power Values will have a tolerance of +/-1 dB
Total EIRP must be calculated based on integrated 16 dBi antenna gain
* Tx Power for 5GHz indicates the combined power.
Tsunami ÂŽ 800 and 8000 Series - Hardware Installation Guide
121
Technical Specifications
5.150 - 5.925 GHz
Tx Power* (dBm)
Products
MP-820-BSU-100
MP-820-SUA-50+
MP-825-SUR-50+
MP-825-BS3-100
MP-825-CPE-50
MP-825-CPE-100
QB-825-EPR/LNK-50
QB-825-EPR/LNK-50+
Stream
Single (or)
Dual Stream
Modulation
40 MHz
20 MHz
10 MHz
5 MHz
BPSK 1/2
26
26
26
26
QPSK 1/2
26
25
25
26
QPSK 3/4
25
24
25
25
16 QAM 1/2
24
24
24
24
16 QAM 3/4
23
23
23
23
64 QAM 2/3
22
22
22
22
64 QAM 3/4
21
21
21
21
64 QAM 5/6
17
18
18
18
: Integrated 15 dBi dual Polarized (H+V) panel antenna (14 dBi beyond 5.850 GHz)
Note:
Output Power Attenuation: 0 – 15 dB, in 1 dB steps
Output Power Values will have a tolerance of +/-2 dB (It is at the lower limit beyond 5.850 GHz)
Total EIRP must be calculated based on integrated 15 dBi antenna gain
* Tx Power for 5GHz indicates the combined power.
5.900 - 6.425 GHz
Tx Power* (dBm)
Products
MP-826-CPE-50
Stream
Single
Stream
Modulation
40 MHz
20 MHz
10 MHz
5 MHz
BPSK 1/2
25
25
25
25
QPSK 1/2
25
25
25
25
QPSK 3/4
25
25
25
25
16 QAM 1/2
24
25
25
25
16 QAM 3/4
23
24
24
24
64 QAM 2/3
23
23
23
23
64 QAM 3/4
21
21
21
21
64 QAM 5/6
20
20
20
20
Tsunami ÂŽ 800 and 8000 Series - Hardware Installation Guide
122
Technical Specifications
5.900 - 6.425 GHz
Note:
Output Power Attenuation: 0 – 22 dB, in 1 dB steps
Output Power Values will have a tolerance of +/-2 dB
Total EIRP must be calculated based on integrated 15 dBi antenna gain
* Tx Power findicated above is the combined power.
Receive Sensitivity
Receive Sensitivity (dBm)
Products
MP-8100-BSU
MP-8100-SUA
MP-8150-SUR
MP-8150-SUR-100
QB-8100-EPA/LNK
QB-8150-EPR/LNK
QB-8150-LNK-100
QB-8151-EPR/LNK
Stream
Single
Stream
Dual
Stream
2.4 GHz
Modulation
5 GHz
40
MHz
20
MHz
10
MHz
5 MHz
40
MHz
20
MHz
10
MHz
5 MHz
BPSK 1/2
-89
-92
-95
-96
-87
-92
-94
-97
QPSK 1/2
-89
-91
-95
-96
-87
-89
-91
-95
QPSK 3/4
-88
-89
-92
-94
-84
-87
-89
-92
16 QAM 1/2
-85
-87
-88
-93
-81
-83
-86
-89
16 QAM 3/4
-82
-85
-84
-90
-78
-80
-83
-86
64 QAM 2/3
-77
-78
-83
-84
-73
-75
-78
-81
64 QAM 3/4
-76
-77
-81
-83
-72
-74
-77
-80
64 QAM 5/6
-74
-73
-79
-81
-70
-72
-75
-78
BPSK 1/2
-85
-87
-90
-93
-87
-90
-92
-95
QPSK 1/2
-83
-85
-87
-89
-84
-87
-89
-92
QPSK 3/4
-79
-81
-84
-86
-81
-84
-87
-90
16 QAM 1/2
-77
-78
-82
-85
-78
-81
-84
-87
16 QAM 3/4
-73
-75
-78
-80
-75
-78
-80
-83
64 QAM 2/3
-68
-71
-74
-76
-71
-73
-76
-79
64 QAM 3/4
-66
-68
-71
-74
-69
-72
-74
-78
64 QAM 5/6
-64
-66
-70
-72
-68
-70
-73
-76
Note: Receive Sensitivity values should be considered with a tolerance +/- 2 dB.
Tsunami ÂŽ 800 and 8000 Series - Hardware Installation Guide
123
Technical Specifications
Products
MP-8100-BSU
MP-8100-SUA
MP-8150-SUR
MP-8150-SUR-100
Stream
Single
Stream
Legacy Data Rate
(Mbps)
Receive Sensitivity (dBm)
5 GHz
20 MHz
10 MHz
5 MHz
-91
-94
-97
-91
-94
-97
12
-92
-94
-96
18
-90
-92
-95
24
-86
-88
-92
36
-83
-85
-88
48
-78
-81
-84
54
-77
-79
-82
Tsunami ÂŽ 800 and 8000 Series - Hardware Installation Guide
124
Technical Specifications
Products
MP-8200-BSU
MP-8250-BS9
MP-8250-BS1
MP-8200-SUA
MP-8250-SUR
QB-8200-EPA/LNK
QB-8250-EPR/LNK
Stream
Single
Stream
Dual
Stream
Receive Sensitivity (dBm)
4.900 - 5.925 GHz
Modulation
40 MHz
20 MHz
10 MHz
5 MHz
BPSK 1/2
-85
-90
-92
-95
QPSK 1/2
-85
-87
-90
-92
QPSK 3/4
-83
-85
-88
-90
16 QAM 1/2
-80
-82
-84
-87
16 QAM 3/4
-76
-78
-81
-84
64 QAM 2/3
-72
-74
-76
-80
64 QAM 3/4
-70
-72
-75
-77
64 QAM 5/6
-68
-71
-73
-76
BPSK 1/2
-85
-88
-90
-93
QPSK 1/2
-82
-85
-87
-91
QPSK 3/4
-80
-83
-85
-88
16 QAM 1/2
-77
-79
-82
-85
16 QAM 3/4
-74
-76
-79
-82
64 QAM 2/3
-69
-72
-74
-77
64 QAM 3/4
-68
-70
-73
-76
64 QAM 5/6
-66
-69
-71
-74
Note: Receive Sensitivity values should be considered with a tolerance +/- 2 dB.
Tsunami ÂŽ 800 and 8000 Series - Hardware Installation Guide
125
Technical Specifications
Products
MP-8200-BSU
MP-8250-BS9
MP-8250-BS1
MP-8200-SUA
MP-8250-SUR
Stream
Single
Stream
Legacy Data Rate
(Mbps)
Receive Sensitivity (dBm)
4.900 - 5.925 GHz
20 MHz
10 MHz
5 MHz
-89
-92
-95
-90
-92
-95
12
-90
-92
-95
18
-88
-90
-93
24
-84
-87
-90
36
-81
-84
-87
48
-77
-79
-82
54
-75
-78
-80
Tsunami ÂŽ 800 and 8000 Series - Hardware Installation Guide
126
Technical Specifications
Products
MP-8160-BSU
MP-8160-BS9
MP-8160-SUA
MP-8160-CPE-A100
Stream
Single
Stream
Dual
Stream
Receive Sensitivity (dBm)
6.4 GHz
Modulation
40 MHz
20 MHZ
10 MHZ
5 MHZ
BPSK 1/2
-90
-92
-95
-98
QPSK 1/2
-88
-90
-92
-96
QPSK 3/4
-86
-87
-90
-94
16 QAM 1/2
-82
-84
-87
-91
16 QAM 3/4
-79
-80
-83
-87
64 QAM 2/3
-75
-77
-79
-83
64 QAM 3/4
-73
-75
-77
-81
64 QAM 5/6
-72
-73
-76
-80
BPSK 1/2
-88
-90
-92
-96
QPSK 1/2
-86
-87
-90
-93
QPSK 3/4
-83
-85
-87
-91
16 QAM 1/2
-80
-81
-84
-88
16 QAM 3/4
-77
-78
-81
-85
64 QAM 2/3
-72
-74
-76
-80
64 QAM 3/4
-71
-72
-75
-78
64 QAM 5/6
-69
-70
-73
-76
Note: Receive Sensitivity values should be considered with a tolerance +/- 2 dB.
Tsunami ÂŽ 800 and 8000 Series - Hardware Installation Guide
127
Technical Specifications
Products
MP-8150-CPE
QB-8150-LNK-12/50
Stream
Single
Stream
Dual Stream
Receive Sensitivity (dBm)
5 GHz
Modulation
40 MHz
20 MHz
10 MHz
5 MHz
BPSK 1/2
-89.0
-93.0
-95
-96
QPSK 1/2
-89.0
-92.0
-93
-94
QPSK 3/4
-87.0
-90.0
-90
-92
16 QAM 1/2
-84.0
-86.0
-87
-89
16 QAM 3/4
-81.0
-83.0
-84
-86
64 QAM 2/3
-77.0
-80.0
-79
-81
64 QAM 3/4
-75.0
-78.0
-78
-80
64 QAM 5/6
-73.0
-76.0
-76
-78
BPSK 1/2
-89.0
-93.0
-93
-94
QPSK 1/2
-89.0
-92.0
-90
-91
QPSK 3/4
-87.0
-90.0
-87
-89
16 QAM 1/2
-84.0
-86.0
-84
-87
16 QAM 3/4
-81.0
-83.0
-81
-83
64 QAM 2/3
-77.0
-80.0
-77
-79
64 QAM 3/4
-75.0
-78.0
-75
-77
64 QAM 5/6
-73.0
-76.0
-73
-75
Note: Receive Sensitivity values should be considered with a tolerance +/- 2 dB.
Tsunami ÂŽ 800 and 8000 Series - Hardware Installation Guide
128
Technical Specifications
Products
MP-820-BSU-100
MP-820-SUA-50+
MP-825-SUR-50+
MP-825-BS3-100
MP-825-CPE-50
MP-825-CPE-100
QB-825-EPR/LNK-50
QB-825-EPR/LNK-50+
Stream
Single
Stream
Dual Stream
Receive Sensitivity (dBm)
5.150 - 5.925 GHz
Modulation
40 MHz
20 MHz
10 MHz
5 MHz
BPSK 1/2
-88
-92
-93
-94
QPSK 1/2
-87
-90
-92
-93
QPSK 3/4
-85
-88
-90
-91
16 QAM 1/2
-82
-85
-87
-89
16 QAM 3/4
-79
-81
-83
-85
64 QAM 2/3
-75
-77
-79
-81
64 QAM 3/4
-73
-75
-77
-79
64 QAM 5/6
-72
-74
-75
-77
BPSK 1/2
-88
-91
-93
-94
QPSK 1/2
-85
-88
-90
-92
QPSK 3/4
-83
-85
-87
-89
16 QAM 1/2
-80
-83
-85
-87
16 QAM 3/4
-77
-79
-81
-83
64 QAM 2/3
-72
-75
-77
-79
64 QAM 3/4
-70
-73
-74
-77
64 QAM 5/6
-69
-71
-72
-75
: Integrated 15 dBi dual Polarized (H+V) panel antenna (14 dBi beyond 5.850 GHz)
Note: Receive Sensitivity values should be considered with a tolerance +/- 2 dB.
Tsunami ÂŽ 800 and 8000 Series - Hardware Installation Guide
129
Technical Specifications
Products
MP-820-BSU-100
MP-820-SUA-50+
MP-825-SUR-50+
MP-825-BS3-100
MP-825-CPE-50
MP-825-CPE-100
Products
MP-826-CPE-50
Stream
Single
Stream
Stream
Single Stream
Dual Stream
Legacy Data Rate
(Mbps)
Receive Sensitivity (dBm)
5.150 - 5.925 GHz
20 MHz
10 MHz
5 MHz
-92
-93
-94
-92
-93
-94
12
-92
-93
-94
18
-90
-91
-92
24
-86
-88
-90
36
-83
-85
-87
48
-79
-81
-83
54
-77
-79
-81
Receive Sensitivity (dBm)
5.900 - 6.425 GHz
Modulation
40 MHz
20 MHz
10 MHz
5 MHz
BPSK 1/2
-89
-92
-95
-97
QPSK 1/2
-87
-90
-93
-95
QPSK 3/4
-85
-87
-90
-92
16 QAM 1/2
-82
-84
-87
-89
16 QAM 3/4
-78
-80
-83
-86
64 QAM 2/3
-74
-76
-79
-81
64 QAM 3/4
-72
-74
-77
-79
64 QAM 5/6
-69
-72
-75
-77
BPSK 1/2
-88
-90
-93
-96
QPSK 1/2
-85
-87
-90
-92
QPSK 3/4
-82
-84
-87
-90
16 QAM 1/2
-79
-81
-84
-87
16 QAM 3/4
-75
-78
-81
-83
64 QAM 2/3
-70
-73
-75
-78
64 QAM 3/4
-68
-71
-73
-76
64 QAM 5/6
-61
-68
-70
-73
Note: Receive Sensitivity values should be considered with a tolerance +/- 2 dB.
Tsunami ÂŽ 800 and 8000 Series - Hardware Installation Guide
130
Technical Specifications
Management
Category
Specification
Local*
RS232 serial CLI (up to 115200 bps)
Telnet and SSH, Web GUI (http) and SSL (https), TFTP
SNMP v1, v2c and v3
SNMP trap and Syslog
Remote
Tsunami ÂŽ 800 and 8000 Series - Hardware Installation Guide
131
Technical Specifications
Power Supply
Products
Category
MP-8100-BSU
MP-8100-SUA
MP-8150-SUR
MP-8150-SUR-100
MP-8200-BSU
MP-8250-BS9
MP-8250-BS1
MP-8200-SUA
MP-8250-SUR
QB-8100-EPA/LNK
QB-8150-EPR/LNK
QB-8150-LNK-100
QB-8151-EPR/LNK
QB-8200-EPA/LNK
QB-8250-EPR/LNK
Specification
Via RJ-45 Ethernet interface supplying 48 VDC and 0.67A on Ethernet Port#1
12 V-DC through RJ-11 serial port (for diagnostic purpose)
Input Voltage
: Only one of the above input voltage options should be used at a time, to
power on the device. Combination of any two options, may damage the
device.
Tabulated below are the power consumption details.
Products
Output Voltage*
Typical
Consumption
Consumption (With
Heaters ON)
MP-8100-BSU
MP-8100-SUA
MP-8150-SUR
MP-8150-SUR-100
QB-8100-EPA/LNK
QB-8150-EPR/LNK
QB-8150-LNK-100
QB-8151-EPR/LNK
QB-8250-EPR/LNK
6 Watts
17 Watts maximum, with
two heaters ON
MP-8200-BSU
MP-8250-BS9
MP-8250-BS1
MP-8200-SUA
MP-8250-SUR
QB-8200-EPA/LNK
QB-8250-EPR/LNK
12 Watts
22 Watts maximum, with
two heaters ON
48VDC through Ethernet Port #2. Power Always ON.
: Output voltage of 48VDC requires a 60-80W high power POE, available
with Proxim Wireless Corporation on request.
Power over
Ethernet Injector
Input: 100 – 250 V-AC (47 – 63 Hz)
Output: 48 V-DC at 0.67 A (32 Watts)
Pin-out: +48 V on pins 4/5, -48 V on pins 7/8
Size: 5.24x2.13x1.42 inches(133x54x36 mm)
Weight: 7 ounces (200 g)
Temp: 0 to 40Âş C
€

‚
ƒ
ƒ
„
†
‚
‡
„
ˆ

€
‰
Š
‹
Œ

Ž

‹

‘
’
‹



“
‚
”
•
Tsunami ÂŽ 800 and 8000 Series - Hardware Installation Guide
–
—
‹
Œ

Ž

‹
˜
™
‹



‚
š

›
ˆ
œ
š

ƒ
ƒ
€
ž

€
”
„
œ
€
”
ˆ
Ÿ

›
ˆ
ž
”
ˆ

Š
€
ž

132
Technical Specifications
Products
Category
MP-8160-BSU
MP-8160-BS9
MP-8160-SUA
Input Voltage
Specification
Via RJ-45 Ethernet interface supplying 48 VDC and 0.67 A on Ethernet Port#1
12 V-DC through serial port (for diagnostic purpose)
Consumption 10 Watts typical (13.8 Watts maximum with one heater ON)
: Only one of the above input voltage options should be used at a time, to
power on the device. Combination of any two options, may damage the
device.
Output Voltage*
Power over
Ethernet Injector
48VDC through Ethernet Port #2. Power Always On.
Products
MP-8150-CPE
QB-8150-LNK-12
QB-8150-LNK-50
Input: 100 – 250 V-AC (47 – 63 Hz)
Output: 48 V-DC at 0.67 A (32 Watts)
Pin-out: +48 V on pins 4/5, -48 V on pins 7/8
Size: 5.24x2.13x1.42 inches(133x54x36 mm)
Weight: 7 ounces (200 g)
Temp: 0 to 40Âş C
Category
Input Voltage
Specification
Via RJ-45 Ethernet interface supplying 48 VDC and 0.40 A on Ethernet Port
12 V-DC through serial port (for diagnostic purpose)
Consumption 7 Watts typical (13.8 Watts maximum)
: Only one of the above input voltage options should be used at a time, to
power on the device. Combination of any two options, may damage the
device.
PoE Injector
Input: 100 – 250 V-AC (47 – 63 Hz)
Output: 48 V-DC at 0.40 A (19 Watts)
Pin-out: +48 V on pins 4/5, -48 V on pins 7/8
Size: 3.98 x 2.40 x 1.35 inches (101.0x61.5x32.2 mm)
Weight: 5.6 ounces (160 g)
Temp: 0 to 40Âş C
Tsunami ÂŽ 800 and 8000 Series - Hardware Installation Guide
133
Technical Specifications
Products
MP-826-CPE-50
Category
Input Voltage
Specification
Via RJ-45 Ethernet interface supplying 48 VDC and 0.40A on Ethernet Port
Consumption of 10 Watts typical (18 Watts max with one heater ON)
PoE Injector
Input: 100 – 250 V-AC (47 – 63 Hz)
Output: 48 V-DC at 0.40 A (19 Watts)
Pin-out: +48 V on pins 4/5, -48 V on pins 7/8
Size: 4.96 x 8.62 x 2.58 inches (126 x 219 x 65.5 mm)
Weight: 5.6 ounces (160 g)
Temp: 0 to 40Âş C
Products
MP-8160-CPE-A100
Category
Specification
Input Voltage
PoE Injector
Products
MP-825-CPE-50
MP-825-CPE-100
QB-825-EPR-50
Via RJ-45 Ethernet interface supplying 48 VDC and 0.40A on Ethernet Port
Consumption 5 Watts typical (10 Watts maximum)
Input: 100 – 250 V-AC (47 – 63 Hz)
Output: 48 V-DC at 0.40 A (19 Watts)
Pin-out: +48 V on pins 4/5, -48 V on pins 7/8
Size: 3.98 x 2.40 x 1.35 inches (101.0x61.5x32.2 mm)
Weight: 5.6 ounces (160 g)
Temp: 0 to 40Âş C
Category
Input Voltage
Specification
PoE Injector
Via RJ-45 Ethernet interface supplying 48 VDC and 0.40A on Ethernet Port
Consumption 6 Watts typical (15 Watts max with two heaters ON)
Input: 100 – 250 V-AC (47 – 63 Hz)
Output: 48 V-DC at 0.40 A (16 Watts)
Pin-out: +48 V on pins 4/5, -48 V on pins 7/8
Size: 3.98 x 2.40 x 1.35 inches (101.0x61.5x32.2 mm)
Weight: 5.6 ounces (160 g)
Temp: 0 to 40Âş C
Tsunami ÂŽ 800 and 8000 Series - Hardware Installation Guide
134
Technical Specifications
Products
MP-820-BSU-100
MP-820-SUA-50+
MP-825-SUR-50+
MP-825-BS3-100
QB-825-EPR/LNK-50+
Category
Input Voltage
Specification
Via RJ-45 Ethernet interface supplying 48 VDC and 0.67A on Ethernet Port#1
12 V-DC through RJ-11 serial port (for diagnostic purpose)
: Only one of the above input voltage options should be used at a time, to
power on the device. Combination of any two options, may damage the
device.
Power
Consumption
PoE Injector
Typical Consumption: 6 Watts
Consumption (With Heaters ON): 16 Watts maximum, with two heaters ON
Input: 100 – 250 V-AC (47 – 63 Hz)
Output: 48 V-DC at 0.67 A (32 Watts)
Pin-out: +48 V on pins 4/5, -48 V on pins 7/8
Size: 5.24x2.13x1.42 inches(133x54x36 mm)
Weight: 7 ounces (200 g)
Temp: 0 to 40Âş C
Hardware Specifications
Products
Radio
Clock
Speed
Memory
Input Power
Power Consumption
MP-8100-BSU
MP-8100-SUA
QB-8100-EPA
2.4 and 5 GHz
MIMO dual band
radio
680 MHz
Flash: 16 MB
RAM: 128 MB
Power-over-Ethernet
48 VDC, 0.67 A
6 Watts typical (17 Watts
max with two heaters ON)
MP-8150-SUR
QB-8150-EPR
4.900 to 5.925 GHz
MIMO radio
680 MHz
Flash: 16 MB
RAM: 128 MB
Power-over-Ethernet
48 VDC, 0.67 A
6 Watts typical (17 Watts
max with two heaters ON)
MP-820-BSU-100
MP-820-SUA-50+
MP-825-SUR-50+
MP-825-BS3-100
QB-825-EPR-50+
5.150 to 5.925 GHz
MIMO radio
560 MHz
Flash: 16 MB
RAM: 128 MB
Power-over-Ethernet
48 VDC, 0.67 A
6 Watts typical (16 Watts
max with two heaters ON)
MP-8150-SUR-100
QB-8150-EPR-100
QB-8151-EPR
4.900 to 5.875 GHz
MIMO radio
680 MHz
Flash: 16 MB
RAM: 128 MB
Power-over-Ethernet
48 VDC, 0.67 A
6 Watts typical (17 Watts
max with two heaters ON)
MP-8200-BSU
MP-8250-BS9
MP-8250-BS1
MP-8200-SUA
MP-8250-SUR
QB-8200-EPA
QB-8250-EPR
4.900 to 5.925 GHz
MIMO High Power
radio
680 MHz
Flash: 16 MB
RAM: 128 MB
Power-over-Ethernet
48 VDC, 0.67 A
12 Watts typical (22 Watts
max with two heater ON)
MP-8160-BSU
MP-8160-BS9
MP-8160-SUA
5.900 to 6.425 GHz
MIMO radio
680 MHz
Flash: 16 MB
RAM: 128 MB
Power-over-Ethernet
48 VDC, 0.67 A
10 Watts typical (13.8
Watts max with one heater
ON)
Tsunami ÂŽ 800 and 8000 Series - Hardware Installation Guide
135
Technical Specifications
MP-8150-CPE
QB-8150-EPR-12
QB-8150-EPR-50
5.3 to 6.1GHz
MIMO radio
333 MHz
333 MHz
Power-over-Ethernet
48 VDC, 0.40 A
7 Watts typical (13.8 Watts
max)
MP-8160-CPE-A100
5.900 to 6.425 GHz
MIMO radio
333 MHz
Flash: 16 MB
RAM: 128 MB
Power-over-Ethernet
48 VDC, 0.40 A
5 Watts typical (10 Watts
max)
MP-825-CPE-50
MP-825-CPE-100
QB-825-EPR-50
5.15 to 5.925 GHz
MIMO radio
560 MHz
Flash: 16 MB
RAM: 128 MB
Power-over-Ethernet
48 VDC, 0.4 A
6 Watts typical (15 Watts
max with two heaters ON)
MP-826-CPE-50
5.900 to 6.425 GHz
MIMO radio
560 MHz
Flash: 16 MB
RAM: 128 MB
Power-over-Ethernet
48 VDC, 0.4 A
10 Watts typical (17 Watts
max with one heater ON)
Tsunami ÂŽ 800 and 8000 Series - Hardware Installation Guide
136
Technical Specifications
Integrated Antenna Specifications
Products: MP-8150-SUR; QB-8150-EPR/LNK; MP-8250-SUR; MP-8250-BS1; QB-8250-LNK
Feature
Specification
Frequency Band
4.900 – 5.875 GHz
Gain
22 dBi (Cable loss included)
3dB Beamwidth
7Âş - 9Âş (Hplane)
3dB Beamwidth
7Âş - 9Âş (Eplane)
Polarization
Dual (Vertical + Horizontal)
Cross Polarization
-25 dB
Port to Port Isolation
-30 dB
Power Handling
5 W (cw)
VSWR
1.7:1 Max
Standard Compliance
ETSI TS3, TS4, TS5
Lightning Protection
DC Ground
Radio Patterns
Tsunami ÂŽ 800 and 8000 Series - Hardware Installation Guide
137
Technical Specifications
Antenna Tilt Angles and corresponding EIRP values:
: These values are applicable only to the devices operating in U-NII-1US frequency band (5.15 - 5.25GHz)
•
-10 degree indicates that the antenna is tilted downwards
•
10 degrees indicates that the antenna is titled upwards
Products: MP-8150-SUR; QB-8150-EPR/LNK; MP-8250-SUR; MP-8250-BS1; QB-8250-LNK
Tilt Angle
Horizontal Side
Lobe
Vertical Side
Lobe
Allowed
Transmit Power
EIRP of Product
12
16
33
-10
12
16
33
-20
19
18
13
39
-30
19
19
14
40
10
12
14
33
20
10
13
31
30
-5
21
Remarks
Not recommended
For detailed exlplanation of the various constituents in the table, please refer Antenna Installation guide > 1.2.3.2 Antenna
Tilt Angles and Corresponding EIRP values in the page number 12
Tsunami ÂŽ 800 and 8000 Series - Hardware Installation Guide
138
Technical Specifications
Products: MP-8150-CPE; QB-8150-LNK-12/50
Feature
Specification
Vertical Polarization
Horizontal Polarization
Frequency Band
5.300 – 6.100 GHz
Gain
15 - 16 dBi
15 - 16 dBi
Horizontal Half Power Beam Width
17.6o
20.3o
16.5o – 18.3o
Vertical Half Power Beam Width
16.1o - 20.5o
17.0o - 24.0o
Sidelobes Level
-10 dB (Max)
-8 dB (Max)
Front-to-back-ratio
23 dB (Max)
-21 dB (Max)
Polarization
Linear, Vertical
Linear, Horizontal
Port to Port Isolation
27 dB (Min.)
Power Handling
6 W (cw)
VSWR
2.0:1 (Max)
Input Impedance
50 ohm
Standard Compliance
ETSI TS3, TS4, TS5
Lightning Protection
DC Ground
–
Radio Patterns
Tsunami ÂŽ 800 and 8000 Series - Hardware Installation Guide
139
Technical Specifications
Product: MP-8160-CPE-A100, MP-826-CPE-50
Feature
Specification
Frequency Range
5900 – 6400 MHz
Polarization
Vertical/Horizontal
Gain
13.5-14.5 dBi / 14.0-15 dBi
Horizontal Half Power Beam Width
35Âş-40Âş / 25Âş-35Âş
Vertical Half Power Beam Width
15Âş- 18Âş
VSWR
2:1 (Max)
Isolation
25 dB (Min)
Input Impedance
50 ohm
Lightning Protection
DC Ground
Radio Patterns (V-Polar Port)
Radio Patterns (H-Polar Port)
Tsunami ÂŽ 800 and 8000 Series - Hardware Installation Guide
140
Technical Specifications
Products: MP-8150-SUR-100; QB-8151-EPR / LNK
Feature
Specification
Vertical Polarization
Frequency Band
4900 - 5875 MHz
Gain
20.0Âą1 dBi
Horizontal Half Power Beam Width
8o (typ.)
Vertical Half Power Beam Width
8o (typ.)
Sidelobes Level
-8 dB (Max)
Front-to-back-ratio
-30 dB (Max)
Polarization
Linear, Vertical
Isolation
25 dB (min.)
Power Handling
2W (cw)
VSWR
2.0: 1 (Max)
Input Impedance
50 ohm
Lightning Protection
DC Ground
Horizontal Polarization
21.0Âą1 dBi
Linear, Horizontal
Radio Patterns
Tsunami ÂŽ 800 and 8000 Series - Hardware Installation Guide
141
Technical Specifications
Antenna Tilt Angles and corresponding EIRP values:
: These values are applicable only to the devices operating in U-NII-1US frequency band (5.15 - 5.25GHz)
Products: MP-8150-SUR-100; QB-8151-EPR / LNK
Tilt Angle
Horizontal Side
Lobe
Vertical Side
Lobe
Allowed
Transmit Power
EIRP of Product
13
13
10
34
-10
13
14
10
34
-20
14
14
11
35
-30
14
14
11
35
10
13
11
32
20
10
28
30
-3
21
Remarks
Not recommended
Products: MP-8160-BS9
Feature
Specification
Frequency Range
5.7 - 6.425 GHz
Polarization
Dual, Vertical and Horizontal
Gain
16 dBi
VSWR, max.
1.7:1
3.5 dB Beam-Width, H-Plane
90Âş
3 dB Beam-Width, E-Plane
8.5Âş
Side Lobes, min.
-25 dB (azimuth)
Cross Polarization, min.
-18 dB
Port to Port Isolation
-45 dB
Front to Back Ratio, min.
-40 dB
Input Power, max
10 Watt
Input Impedance
50 Ohm
Lightning Protection
DC Grounded
Tsunami ÂŽ 800 and 8000 Series - Hardware Installation Guide
142
Technical Specifications
Products: MP-8160-BS9
Feature
Specification
Radio Patterns
MP-825-CPE-50, MP-825-CPE-100, MP-825-SUR-50+, MP-825-BS3-100, QB-825-LNK-50, and QB-825-LNK-50+
Feature
Specification
Vertical Polarization
Horizontal Polarization
Frequency Band
5.15 - 5.925 MHz
Gain
15 - 16 dBi (14 dBi beyond 5.850 GHz)
Horizontal Half Power Beam Width
31o – 38o
30o – 34o
Vertical Half Power Beam Width
14o - 16o
14o - 17o
Sidelobes Level
12 dB (Min)
10 dB (Min)
Polarization
Dual, Vertical and Horizontal
Isolation
> 30 dB typl.
VSWR
< 2.0:1 (Max)
Lightning Protection
DC Grounded
Tsunami ÂŽ 800 and 8000 Series - Hardware Installation Guide
143
Technical Specifications
MP-825-CPE-50, MP-825-CPE-100, MP-825-SUR-50+, MP-825-BS3-100, QB-825-LNK-50, and QB-825-LNK-50+
Feature
Specification
Radio Patterns (V-Polar Port)
Radio Patterns (H-Polar Port)
Antenna Tilt Angles and corresponding EIRP values:
: These values are applicable only to the devices operating in U-NII-1US frequency band (5.15 - 5.25GHz)
MP-825-CPE-50, MP-825-CPE-100, MP-825-SUR-50+, MP-825-BS3-100, QB-825-LNK-50, and QB-825-LNK-50+
Tilt Angle
Horizontal Side
Lobe
Vertical Side
Lobe
Allowed
Transmit Power
EIRP of Product
13
11
30
-10
13
16
15
34
-20
13
16
15
34
-30
13
20
15
34
10
13
10
29
20
21
30
21
Tsunami ÂŽ 800 and 8000 Series - Hardware Installation Guide
Remarks
144
Technical Specifications
Products: MP-8250-BS9
Feature
Specification
Frequency Band
4.9 – 6.1 MHz
Gain, typ.
16 dBi
VSWR, Max.
1.7:1
Polarization
Dual Pol., Vertical and Horizontal
3 dB Beam-Width, H-Plane, typ.
90o
3 dB Beam-Width, E-Plane, typ.
8o
Sidelobes Level, Min.
V-Pol: ETSI EN 302 085 V1.2.3 – CS2
H-Pol: ETSI EN 302 085 V1.2.3 – CS3
Cross Polarization, min.
-15 dB
Front to Back Ratio, min.
-30 dB
Port to Port Isolation, min.
-30 dB
Input power, max
10 Watt
Input Impedance
50 Ohm
Lightning Protection
DC Grounded
Radio Patterns (V-Polar Port)
Tsunami ÂŽ 800 and 8000 Series - Hardware Installation Guide
145
Technical Specifications
Products: MP-8250-BS9
Feature
Specification
Radio Patterns (H-Polar Port)
Antenna Tilt Angles and corresponding EIRP values:
: These values are applicable only to the devices operating in U-NII-1US frequency band (5.15 - 5.25GHz)
Products: Products: MP-8250-BS9
Tilt Angle
Horizontal Side
Lobe
Vertical Side
Lobe
Allowed
Transmit Power
EIRP of Product
16
18
18
37
-10
17
18
19
38
-20
17
18
19
38
-30
17
20
19
38
10
17
18
19
38
20
13
10
12
31
30
21
Tsunami ÂŽ 800 and 8000 Series - Hardware Installation Guide
Remarks
146
Technical Specifications
Physical Specifications
Products
Category
Specification
MP-8100-BSU,
MP-8100-SUA
QB-8100-EPA
Dimensions (L x W x H)
10.79 x 11.14 x 3.38 inches (274 x 283 x 86 mm)
Weight
7.7 lbs (3.5 kg)
MP-8150-SUR
QB-8150-EPR
Dimensions (L x W x H)
14.57 x 14.57 x 4.47 inches (370 x 370 x 113.5 mm)
Weight
9.0 lbs (4.1 kg)
MP-8150-SUR-100
QB-8150-EPR-100
QB-8151-EPR
Dimensions (L x W x H)
14.57 x 14.57 x 4.21 inches (370 x 370 x 107 mm)
Weight
8.45 lbs (3.85 kg)
MP-8200-BSU
MP-8200-SUA
QB-8200-EPA
Dimensions (L x W x H)
10.79 x 11.14 x 3.38 inches (274 x 283 x 86 mm)
Weight
7.9 lbs (3.6 kg)
MP-8250-SUR
MP-8250-BS9
MP-8250-BS1
QB-8250-EPR
Dimensions (L x W x H)
14.57 x 14.57 x 4.47 inches (370 x 370 x 113.5 mm)
Weight
9.26 lbs (4.2 kg)
MP-8160-BSU
MP-8160-SUA
Dimensions (L x W x H)
10.79 x 11.14 x 3.38 inches (274 x 283 x 86 mm)
Weight
7.38 lbs (3.35 kg)
MP-8160-BS9
Dimensions (L x W x H)
14.57 x 14.57 x 4.47 in (370 x 370 x 113.5 mm)
Weight
8.82 lbs (4 kg)
Dimensions (L x W x H)
7.77 x 7.56 x 3.94 inches (197.5 x 192 x 100mm)
Weight
1.6 lbs (0.73 kg)
Dimensions (L x W x H)
8.46 x 4.78 x 2.56 inches (215 x 121.5 x 65 mm)
Weight
1.93 lbs (0.88 kg)
MP-820-BSU-100
MP-820-SUA-50+
Dimensions (L x W x H)
5.02 x 8.68 x 2.85 inches (127.5 x 220.5 x 72.5 mm)
Weight
2.75 lbs (1.250 kg)
MP-826-CPE-50
MP-825-CPE-50
MP-825-CPE-100
MP-825-SUR-50+
MP-825-BS3-100
QB-825-EPR-50
QB-825-EPR-50+
Dimensions (L x W x H)
4.96 x 8.62 x 2.58 inches (126 x 219 x 65.5 mm)
Weight
2.1 lbs (0.95 kg)
QB-8150-EPR-12
QB-8150-EPR-50
Dimensions (L x W x H)
7.77 x 7.56 x 3.94 inches (197.5 x 192 x 100mm)
Weight
1.6 lbs (0.73 kg)
MP-8150-CPE
MP-8160-CPE-A100
Tsunami ÂŽ 800 and 8000 Series - Hardware Installation Guide
147
Technical Specifications
Environmental Specifications
Products
Operating Temperature
Storage Temperature
MP-8100-BSU; MP-8100-SUA
MP-8150-SUR; MP-8150-SUR-100
MP-8200-BSU; MP-8200-SUA
MP-8250-SUR; MP-8160-BSU
MP-8160-BS9; MP-8160-SUA
MP-8250-BS9; MP-8250-BS1
QB-8100-EPA/LNK; QB-8150-EPR/LNK
QB-8150-LNK-100; QB-8151-EPR/LNK
QB-8200-EPA/LNK; QB-8250-EPR/LNK
-40Âş to 60ÂşC
(-40Âş to 140Âş Fahrenheit)
-55Âş to 80ÂşC
(-67Âş to 176Âş Fahrenheit)
100% (non-condensing)
MP-8150-CPE
QB-8150-LNK-12/50
-35Âş to 55ÂşC
(-31Âş to 131Âş Fahrenheit)
-40Âş to 70ÂşC
(-40Âş to 158Âş Fahrenheit)
Max 95% relative humidity
(non-condensing)
MP-8160-CPE-A100
-40° to 55°C
(-40° to 131° Fahrenheit)
-45Âş to 70ÂşC
(-49Âş to 158Âş Fahrenheit)
Max 95% relative humidity
(non-condensing)
MP-826-CPE-50
MP-825-CPE-50
MP-825-CPE-100
MP-820-BSU-100
MP-820-SUA-50+
MP-825-SUR-50+
MP-825-BS3-100
QB-825-EPR/LNK-50+
QB-825-EPR/LNK-50
-40Âş to 55ÂşC (-40Âş to 131Âş
Fahrenheit)
-55Âş to 70ÂşC (-67Âş to 158Âş
Fahrenheit)
100% (non-condensing)
Tsunami ÂŽ 800 and 8000 Series - Hardware Installation Guide
Humidity
148
Technical Specifications
MTBF
Products
MTBF
MP-8100-BSU
MP-8100-SUA
MP-8150-SUR
MP-8150-SUR-100
MP-8160-BSU
MP-8160-BS9
MP-8160-SUA
QB-8100-EPA/LNK
QB-8150-EPR/LNK
QB-8150-LNK-100
QB-8151-EPR/LNK
>80,000 hours
MP-8150-CPE
MP-8160-CPE-A100
QB-8150-LNK-12/50
75,000 hours
MP-826-CPE-50
>2,00,000 hours
MP-8200-BSU
MP-8250-BS9
MP-8250-BS1
MP-8200-SUA
MP-8250-SUR
QB-8200-EPA/LNK
QB-8250-EPR/LNK
>250,000 hours
MP-820-BSU-100
MP-820-SUA-50+
MP-825-SUR-50+
MP-825-BS3-100
MP-825-CPE-50
MP-825-CPE-100
QB-825-EPR/LNK-50
QB-825-EPR/LNK-50+
>350,000 hours
Tsunami ÂŽ 800 and 8000 Series - Hardware Installation Guide
149
Appendix - Additional Weatherproofing Steps
This chapter explains the method to add an additional layer of protection to the connectors (Ethernet) against the
environment.
: We have taken MP-8100-BSU as an example to explain the weatherproofing steps. The same method
should be followed to weatherproof the Ethernet connectors of the TsunamiÂŽ 800 and 8000 series
products.
A.1 Material for Weatherproofing
The material required for weatherproofing connectors are,
1. Any standard Butyl Mastic Tape
2. Any standard Vinyl Tape
We have used the following Butyl Mastic Tape and Vinyl Tape as an example to demonstrate the weatherproofing steps:
A.2 Weatherproofing Steps
1. Wrap a vinyl tape in a half-lapped fashion, from the weatherproofed connector end and continue wrapping till 3
inches onto the cable.
(a)
(b)
(c)
Figure A-1 Step1
Tsunami ÂŽ 800 and 8000 Series - Hardware Installation Guide
150
Appendix - Additional Weatherproofing Steps
2. Wrap a second layer of the vinyl tape over the first layer but in other direction.
(a)
(b)
Figure A-2 Step2
3. Now, wrap a layer of vinyl tape with the adhesive side out as it provides sticky surface for the next layer.
(a)
(b)
Figure A-3 Step3
4. Next, wrap a layer of the butyl mastic tape on the adhesive side.
(a)
(b)
Figure A-4 Step3
5. Finally, wrap vinyl tap over the butyl layer.
(a)
(b)
Figure A-5 Step3
Tsunami ÂŽ 800 and 8000 Series - Hardware Installation Guide
151
Appendix - Lightning Protection
Lightning protection is used to maximize the reliability of the communications equipment by safely re-directing current from
a lightning strike or a power surge traveling along the Cat 5/Cat5e/Cat 6 Ethernet cabling to the ground using the shortest
path possible. Designing a proper grounding system prior to installing any communications equipment is critical to minimize
the possibility of equipment damage, void warranties, and cause serious injury.
The surge arrestor (sometimes referred to as a lightning protector) can protect your sensitive electronic equipment from
high-voltage surges caused by discharges and transients at the PoE.
Proxim Wireless offers superior lightning and surge protection for TsunamiÂŽ series products. Contact your reseller or
distributor for more information.
Tsunami ÂŽ 800 and 8000 Series - Hardware Installation Guide
152
Appendix - Abbreviations
Abbreviations
AWG
American Wire Gauge
BSU
Base Station Unit
CLI
Command Line Interface
CPE
Customer Premises Equipment
DC
Direct Current
ESD
Electrostatic Discharge
FCS
Frame Check Sequence
LED
Light Emitting Diode
MIMO
Multiple-input and Multiple-output
MTBF
Mean Time Between Failures
OFDM
Orthogonal frequency-division multiplexing
PC
Personal Computer
PoE
Power Over Ethernet
PTMP
Point-to-multipoint
PTP
Point-to-point
QB
Quick Bridge
QIG
Quick Installation Guide
RSSI
Received Signal Strength Indicator
Rx
Receiver
SU
Subscriber Unit
Tx
Transmission
WORP
Wireless Outdoor Router Protocol
Tsunami ÂŽ 800 and 8000 Series - Hardware Installation Guide
153
Appendix - Statement of Warranty
Warranty Coverage
Proxim Wireless Corporation warrants that its products are manufactured solely from new parts, conform substantially to
specifications, and will be free of defects in material and workmanship for a Warranty Period of 1 year from the date of
purchase.
Repair or Replacement
When Proxim determines that a returned product does not meet the warranted criteria during the warranty period, Proxim at
its option, will either: (a) repair the defective product; (b) replace the defective product with a new or refurbished product
that is at least equivalent to the original; or (c) refund the price paid for the defective product. Generally, products are
repaired or replaced within thirty (30) business days of receipt of the product at a Proxim Logistical/Repair Center. The
warranty period for repaired or replacement products is ninety (90) days or the remainder of the original warranty period,
whichever is longer. These three alternatives constitute the customer’s sole and exclusive remedy and Proxim’s sole and
exclusive liability under warranty provisions.
Limitations of Warranty
Proxim’s warranties do not apply to any product (hardware or software) which has (a) been subjected to abuse, misuse,
neglect, accident, or mishandling, (b) been opened, repaired, modified, or altered by anyone other than Proxim, (c) been
used for or subjected to applications, environments, or physical or electrical stress or conditions other than as intended and
recommended by Proxim, (d) been improperly stored, transported, installed, or used, or (e) had its serial number or other
identification markings altered or removed.
Buyers can contact Proxim Wireless Customer Service Center either by telephone or via web. Support and repair of products
that are out of warranty will be subject to a fee. Contact information is shown below. Additional support information can be
found at Proxim Wireless’s web site at
ÂĄ
¢
¢
ÂŁ
¤
ÂĽ
ÂĽ
ÂŚ
§
¨
ÂŁ
Š
ÂŞ
ÂŤ
ÂŹ
ÂŚ
¨
­
ÂŞ
ÂŚ
Contact technical support via telephone as follows:
USA and Canada Customers
Phone: +1-408-383-7700; +1-866-674-6626
Business Hours: 24x7 live response. Tier 3 support: 8 a.m. to 5 p.m. M-F PDT (UTC/GMT -7 hrs)
International Customers
Phone: +1-408-383-7700; 0800-916475 (France); 8-800-100-9485 (Russia)
Business Hours: 24x7 live response. Tier 3 support: 8 a.m. to 5 p.m. M-F PDT (UTC/GMT -7 hrs)
Tsunami ÂŽ 800 and 8000 Series - Hardware Installation Guide
154
Appendix - Statement of Warranty
General Procedures
When contacting the Customer Service for support, Buyer should be prepared to provide the product description and serial
number and a description of the problem. The serial number should be on the product.
In the event the Customer Service Center determines that the problem can be corrected with a software update, Buyer might
be instructed to download the update from Proxim Wireless’s web site or, if that’s not possible, the update will be sent to
Buyer. In the event the Customer Service Center instructs Buyer to return the product to Proxim Wireless for repair or
replacement, the Customer Service Center will provide Buyer a Return Material Authorization (“RMA”) number and shipping
instructions. Buyer must return the defective product to Proxim Wireless, properly packaged to prevent damage, shipping
prepaid, with the RMA number prominently displayed on the outside of the container.
Calls to the Customer Service Center for reasons other than product failure will not be accepted unless Buyer has purchased a
Proxim Wireless Service Contract or the call is made within the warranty period. After the warranty period, Technical Support
is fee based (detailed in
).
ÂŽ
ÂŁ
ÂŁ
ÂŻ
°
Âą
ÂŹ
ÂŤ
²
Âł
ÂŻ
­
ÂĄ
°
ÂŹ
­
´
Âľ
Âś
ÂŻ
Š
¡
ÂŹ
­
ÂŻ
¸
´
°
Âą
Âś
š
ÂŁ
ÂŁ
ÂŞ
Š
¢
If Proxim Wireless reasonably determines that a returned product is not defective or is not covered by the terms of this
Warranty, Buyer shall be charged a service charge and return shipping charges.
Other Information
Search Knowledgebase
Proxim Wireless stores all resolved problems in a solution database at the following URL:
ÂĄ
¢
¢
ÂŁ
¤
ÂĽ
ÂĽ
ÂŚ
§
¨
ÂŁ
Š
ÂŞ
ÂŤ
ÂŹ
ÂŚ
¨
­
ÂŞ
ÂŚ
Create a Support Request
Create a support request with Proxim Wireless technical support staff at the following URL:
ÂĄ
¢
¢
ÂŁ
¸
¤
ÂĽ
ÂĽ
ÂŚ
§
¨
ÂŁ
Š
ÂŞ
ÂŤ
ÂŹ
ÂŚ
¨
­
ÂŞ
ÂŚ
ÂĽ
°
ÂŻ
Âş
Âť
­
´
¸
ÂŻ
Tsunami ÂŽ 800 and 8000 Series - Hardware Installation Guide
155
Appendix - Technical Services and Support
Obtaining Technical Service and Support
If you are having trouble using the Proxim product, please read this manual and the additional documentation provided with
your product. If you require additional support to resolve your issue, please be ready to provide the following information
before you contact Proxim’s Technical Services team:
Product information
– Part number and serial number of the suspected faulty device
Trouble/error information
– Trouble/symptom being experienced
– Activities completed to confirm fault
– Network information (What kind of network are you using?)
– Circumstances that preceded or led up to the error
– Message or alarms viewed
– Steps taken to reproduce the problem
ServPak information (if a Servpak customer):
– ServPak account number
Registration information
– If the product is not registered, date and location where you purchased the product
: Technical Support is free for the warranty period from the date of purchase.
Support Options
Proxim eService Web Site Support
The Proxim eService Web site is available 7x24x365 at
ÂĄ
¢
¢
ÂŁ
¤
ÂĽ
ÂĽ
ÂŚ
§
¨
ÂŁ
Š
ÂŞ
ÂŤ
ÂŹ
ÂŚ
¨
­
ÂŞ
ÂŚ
On the Proxim eService Web Site, you can access the following services:
Product Download Page: Provides quick links to product firmware, software, and documentation downloads.
Proxim TV Links: A link to helpful video tutorials.
Knowledgebase: A solution database of all the resolved problems. You can search by product, category, keywords,
or phrases.
Live Chat: Chat with a support technician on-line or request to call back at a later time.
Create a Support Request: Create a support request with our technical support staff who will reply to you by email.
Case Management: Login to check the status of your support cases, update your personal profile, or access
restricted information and features.
Provide Feedback: Submit a suggestion, complaint, or other feedback about the support site and our products.
Tsunami ÂŽ 800 and 8000 Series - Hardware Installation Guide
156
Appendix - Technical Services and Support
Telephone Support
Contact technical support via telephone as follows:
USA and Canada Customers
Phone: +1-408-383-7700; +1-866-674-6626
Business Hours: 24x7 live response. Tier 3 support: 8 a.m. to 5 p.m. M-F PDT (UTC/GMT -7 hrs)
International Customers
Phone: +1-408-383-7700; 0800-916475 (France); 8-800-100-9485 (Russia)
Business Hours: 24x7 live response. Tier 3 support: 8 a.m. to 5 p.m. M-F PDT (UTC/GMT -7 hrs)
ServPak Support
To provide even greater investment protection, Proxim Wireless offers a cost-effective support program called ServPak.
ServPak is a program of enhanced service support options that can be purchased as a bundle or individually, tailored to meet
your specific needs. Whether your requirement is round the clock technical support or advance replacement service, we are
confident that the level of support provided in every service in our portfolio will exceed your expectations.
All ServPak service bundles are sold as service contracts that provide coverage for specific products from 1 to 3 years. Servpak
bundles are considered an upgrade to the standard product warranty and not an extension.
Priority Advanced
Replacement
(Next business day/
International priority
shipment service)
Priority Comprehensive
Advance Replacement
(Next business day/
International priority
shipment service)
8x7 Advanced Technical
Support
24x7 Advanced Technical
Support
24x7 Advanced Technical
Support
Software Maintenance
PVES & PV NMS
Support
PVES & PV NMS
Support
24x7 Basic Technical
Support
Basic Advanced
Replacement
(Two business days/
International economy
shipment service)
Access to Knowledge
Base
Post-Installation
Optimization
50% discount on Onsite
Technical Support and
Services
Tsunami ÂŽ 800 and 8000 Series - Hardware Installation Guide
157
Appendix - Technical Services and Support
Additional Information on ServPak Options
Advanced Replacement of Hardware
In the event of a hardware failure, our guaranteed turnaround time for return to factory repair is 30 days or less. Customers
who purchase this service are guaranteed replacement of refurbished or new hardware to be shipped out within one or two
business days, as applicable. Options are available for shipment services depending on the customer’s support needs.
Hardware is shipped on business days, Monday – Friday excluding Holidays, 8:00 AM – 3:30 PM Eastern Time.
Comprehensive Advanced Replacement of Hardware
In addition to ServPak Prime options, in the event of a hardware failure, Proxim will repair or replace the failed product for any
reason, other than vandalism.
7x24x365 Availability
Unlimited, direct access to technical support engineers 24 hours a day, 7 days a week, 365 days a year including Holidays.
8x5 Availability
Unlimited, direct access to world-class technical support engineers 8 hours a day, 5 days a week, Monday through Friday from
8:00AM - 5:00PM Pacific Standard Time.
Basic Technical Support
Customers who purchase this service can be rest assured that their call will be answered by Proxim’s Tier 1 technical support
and a case opened immediately to document the problem and provide initial troubleshooting to identify the solution and
resolve the incident in a timely manner.
Advanced Technical Support
In addition to Proxim’s world-class Tier 1 technical support, customers will be able to have their more complex issues escalated
to our world-class Tier 3 technical support engineers. Our Tier 3 engineers will review specific configurations to troubleshoot
intricate issues and will also provide helpful insights regarding Proxim’s products and various tips from decades of collective
experience in the wireless industry.
Software Maintenance
It's important to maintain and enhance security and performance of wireless equipment and Proxim makes this easy by
providing a Software Maintenance program that enables customers to access new feature and functionality rich software
upgrades and updates. Customers will also have full access to Proxim's vast Knowledgebase of technical bulletins, white
papers and troubleshooting documents.
Post-Installation Optimization
You can consult with our technical support engineers to enhance performance and efficiency of your network.
Post-installation optimization services include:
Review frequencies to select best possible channel
Review Modulation, Channel Bandwidth, MIMO, and WORP settings to optimize throughput and link quality
Review Satellite Density & TPC/ATPC settings
Assistance with Bandwidth controls
Tsunami ÂŽ 800 and 8000 Series - Hardware Installation Guide
158
Appendix - Technical Services and Support
Assistance with QoS, RADIUS, and VLAN settings on Proxim equipment
To purchase ServPak support services, please contact your authorized Proxim distributor. To receive more information or for
questions
on
any
of
the
available
ServPak
support
options,
please
visit
our
website
at
, call Proxim Support (For telephone numbers, see
) or send an
email to
ÂĄ
¢
¢
ÂŁ
¤
ÂĽ
ÂĽ
Âş
Âş
Âş
¸
¨
ÂŻ
ÂŁ
Š
Š
¡
ÂŞ
ÂŁ
ÂŤ
´
ÂŹ
Âź
ÂŚ
¨
½
­
ÂŞ
ÂŁ
ÂŚ
Š
ÂŞ
ÂĽ
ÂŤ
¸
ÂŹ
š
ÂŚ
ÂŁ
¨
ÂŁ
­
ÂŞ
ÂŞ
Š
¢
ÂĽ
¸
ÂŻ
Š
¡
ÂŁ
´
Âź
Âł
ÂŻ
Âľ
ÂŻ
ÂŁ
ÂĄ
ÂŞ
°
ÂŻ
Âś
š
ÂŁ
ÂŁ
ÂŞ
Š
¢
ÂŚ
Technical Support Policy
Technical Support for Current Products during Warranty Period
All Customers are entitled to free technical support for the Proxim products they purchase from Proxim’s authorized resellers
or distributors. Technical Support is defined as communication via the Proxim Support website (
) and/or
via telephone. This technical support will be provided for free for the entire time the product is covered by a Proxim
warranty.The term of Proxim’s warranty is determined according to the agreement under which the product was sold and
generally varies from 3 months to 2 years depending on the product. If a Customer disagrees with Proxim’s determination of
warranty duration, a request for review supported by a copy of all product purchase documentation may be submitted.
ÂĄ
¢
¢
ÂŁ
¤
ÂĽ
ÂĽ
ÂŚ
§
¨
ÂŁ
Š
ÂŞ
ÂŤ
ÂŹ
ÂŚ
¨
­
ÂŞ
ÂŚ
Technical Support for Current Products after Warranty Period
After the warranty period, technical support on products then being sold by Proxim will be based upon one of the following
three options Customers can choose:
Customers can choose to purchase one of Proxim’s ServPak extended warranty and enhanced support packages for
the product
Customers can choose to purchase one-time per-incident technical support for the product for a fee
Customers can choose to call the reseller or distributor who sold them the product for technical support
Tech Support on Discontinued Products
Technical Support on some products that Proxim has declared as EOL (End of Life) or otherwise is no longer selling is available
based upon one of the following three options Customers can choose:
For some discontinued products, Customers can choose to purchase one of Proxim’s EOL ServPak support packages
for the product
– No EOL ServPak support package will be available for any product discontinued more than 5 years ago
– No EOL ServPak support package is available for certain discontinued products
Customers can choose to purchase one-time per-incident technical support for the product on a per hour basis at a
rate of $125 an hour (4 hours minimum payable in advance by major credit card). This fee is payable in addition to any
RMA fee that may be charged to subsequently repair the product.
Customers can choose to call the reseller or distributor who sold them the product for technical support
All Proxim technical support for discontinued products, whether through an EOL ServPak package or otherwise, is provided
on a “best effort” basis and is subject to the continued availability of necessary components, equipment, and other technical
resources.
Note that Proxim is unable to support or warrant any equipment that has been modified, whether this modification is
physical, or if third-party software codes have been loaded onto the product.
Tsunami ÂŽ 800 and 8000 Series - Hardware Installation Guide
159

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.4
Linearized                      : No
Page Count                      : 79
Producer                        : GPL Ghostscript 8.15
Create Date                     : 2014:06:06 09:54:57
Modify Date                     : 2014:06:06 09:54:57
Title                           : Hardware Installation Guide.pdf
Creator                         : Adobe Acrobat 11.0.7
Author                          : CHsieh
EXIF Metadata provided by EXIF.tools
FCC ID Filing: HZB-PROXMB82