Psion 7505BTSDCMHC25 Handheld Computer User Manual QUICK MR1100 User Guide
Psion Inc Handheld Computer QUICK MR1100 User Guide
Psion >
Contents
User Guide
MORPHO™ RAPID QUICK USER’S GUIDE MorphoRapID™ Specifications M O R P H O R A P ID Q U I C K USER’S GUIDE 1. M orp h oRa pI D™ S p ec i f ic a tion s Technical Specifications • Size: 3.7" Display • VGA Display: 640 x 480 high resolution LCD Touch Panel • 65536 Full-Colors • 500 DPI in X and Y axis Sensor • 8-bit gray scale • Acquisition area 21 x 21 mm (0,8 x 0,8 ") Input/Output USB 2.0 Power PSA 15R-050P Model - Input: AC 100-240 V~ 50-60 Hz 0.5 A - Output: DC 5.0 V 3.0 A Temperature Range • Operating +0°C to 45°C • Storage -20°C to 70°C Humidity • Operating 15% < RH < 95% non-condensing • Storage < 95% Weight 800 g Dimensions 89 x 126 x 185 mm NOTE A removable power cord connects the MorphoRapID™ to the mains supply - Its socketoutlet shall be near the MorphoRapID™ and shall be easily accessible. 0000025754-07 - OCTOBER 2008 SAGEM SÉCURITÉ DOCUMENT - REPRODUCTION AND DISCLOSURE PROHIBITED. MORPHO™ RAPID QUICK USER’S GUIDE International Standards 2. In t e rn at ion a l S t an d a rd s The MorphoRapID™ terminal complies with both European and U.S. standards as follows: Region Standards Europe EMC Directive 89/336/EEC: EN55022 (1994) / EN55024 (1998) Low voltage Directive 73/23/EEC amended by 93/68/EEC: EN60950 (2000) USA FCC part 15 Class A digital device requirements USA This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense. Radiation Exposure Compliance This product complies with the FCC RF exposure limits for an uncontrolled environment. For continued compliance, the product must not be held closer than 20 cm from the rest of the body. This product must not be used in a holster or on a belt-clip.’ This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter. WARNING Changes or modifications not expressly approved by the party responsible for the compliance could void the user’s authority to operate the equipment. Canada This Class A digital apparatus meets all requirements of the Canadian Interference-Causing Equipment Regulations. When using the 802.11 radio option, to prevent radio interference, this device is intended to be operated indoors and away from windows to provide maximum shielding. Equipment (or its transmit antenna) that is installed outdoors is subject to licensing. Cet appareil numérique de la classe A respecte toutes les exigences du Règlement sur le matériel brouilleur du Canada. En cas d’utilisation du module radio 802.11, afin d'éviter toute interférence radio avec le service autorisé, l'appareil doit être utilisé à l'intérieur, tout en étant éloigné de toute fenêtre afin de garantir le maximum de protection. Si cet équipement (ou son antenne émettrice) est installé à l'extérieur, il est alors soumis à licence. 0000025754-07 - OCTOBER 2008 SAGEM SÉCURITÉ DOCUMENT - REPRODUCTION AND DISCLOSURE PROHIBITED. MORPHO™ RAPID QUICK USER’S GUIDE Model Morpho RapID 1100 MorphoRapID™ Specifications Option Standard version Morpho RapID 1100 W WiFi Morpho RapID 1100 G GSM/GPRS/3G Morpho RapID 1100 WG 0000025754-07 - OCTOBER 2008 SAGEM SÉCURITÉ DOCUMENT - REPRODUCTION AND DISCLOSURE PROHIBITED. WiFi - GSM/GPRS/3G MORPHO™ RAPID QUICK USER’S GUIDE Cleaning 3. Cl e an in g Clean the MorphoRapID™ body, screen and biometric sensor with a dry, non-abrasive, lint-free cloth and only with a cleaning product recommended by Sagem Sécurité. During periods of intense activity, the sensor should be cleaned as soon as smears are visible on-screen. WARNING Avoid using any alcohol or by-products that could damage the MorphoRapID™ body or sensor part (cracks may appear on body or prism). Examples of corrosive chemicals to be avoided: – acetone, – ammoniac, – benzene, – ethanol, – methanol, – methylated spirit, – petrol, – thichlorethylene. 0000025754-07 - OCTOBER 2008 SAGEM SÉCURITÉ DOCUMENT - REPRODUCTION AND DISCLOSURE PROHIBITED. MORPHO™ RAPID QUICK USER’S GUIDE Battery 4. B att e r y Precautions Battery Handling The battery handling precautions for MorphoRapID™ batteries are: WARNING • The battery used in this device may present a fire or chemical burn hazard if mistreated. • Do not disassemble, heat above 100°C (212°F) or incinerate. • Never short-circuit the pack. It may cause electrolyte leakage, gazing or fire. • Avoid all risk of short-circuit when handling the batteries or during storage. • Leakage under conditions of intended use and reasonably foreseeable misuse shall not occur. Even so if electrolyte leaks out of the pack and comes into contact with the skin, eyes or others parts of body, the electrolyte should be flushed immediately with fresh water. Seek medical advice from a physician. • Never incinerate nor dispose of pack into fire. • The pack should never be soaked in liquid. • If any abnormal features of the pack are found such as: damage to the plastic envelope, deformation of the pack, smell of electrolyte, electrolyte leakage, or other abnormalities, the cell should not be used anymore. Battery Replacement The battery replacement precautions are (see Battery Replacement): WARNING Danger of explosion if battery is incorrectly replaced. Replace only with the same battery type. Must be disposed of properly. 0000025754-07 - OCTOBER 2008 SAGEM SÉCURITÉ DOCUMENT - REPRODUCTION AND DISCLOSURE PROHIBITED. MORPHO™ RAPID QUICK USER’S GUIDE Battery Battery Transportation It is recommended to remove batteries from the terminal when the product is transported on long distance. Battery Charge It is mandatory to only use the battery charger delivered by Sagem Sécurité for the MorphoRapID™ product for MorphoRapID™ battery charge. The battery pack should be charged within the range of specified temperatures. If the pack is charged at a temperature out of the specified range, leakage, heat generation, or other damages may occur. The battery pack should be discharged within the range of specified temperatures. NOTE Do not use MorphoRapID™ batteries for any other use than the MorphoRapID™ product. It should be noted that the battery pack may be overdischarged if the pack is not used for a long time. In order to prevent overdischarging, the pack should be charged periodically. Overdischarging may cause loss of pack performance, or damage battery functions. So as to keep a correct autonomy, it is recommended to regularly perform complete charge/discharge cycles. To switch the terminal off for a period of storage longer than 7 days, it is WARNING advised to disconnect the battery. In the same way, to preserve battery life during a long period of storage, it is advised to disconnect or to remove the battery with a minimum charge of 30% of battery capacity and not in deep discharge (0%). Power Supply Precautions The installation and maintenance of the MorphoRapID™ should be made by a qualified service person and should conform to all local codes. Before plugging the power source to your MorphoRapID™, check that the power source you intend to connect do complies with the voltage, current and frequency specifications on the rating label on the power supply unit. NOTE Use only the power supply unit provided with your MorphoRapID™. 0000025754-07 - OCTOBER 2008 SAGEM SÉCURITÉ DOCUMENT - REPRODUCTION AND DISCLOSURE PROHIBITED. MORPHO™ RAPID QUICK USER’S GUIDE Battery Battery Replacement Here are the instructions to replace the battery: Screen Action 1 At the back of the device, unlatch the battery cover latches. 2 Open the battery compartment by pulling and sliding its cover. 3 Take the discharged battery off its compartment. 0000025754-07 - OCTOBER 2008 SAGEM SÉCURITÉ DOCUMENT - REPRODUCTION AND DISCLOSURE PROHIBITED. MORPHO™ RAPID QUICK USER’S GUIDE Screen Battery Action 4 Replace the discharged battery by the charged one: insert the new battery. 5 Close the battery compartment. 6 Latch the battery compartment. 0000025754-07 - OCTOBER 2008 SAGEM SÉCURITÉ DOCUMENT - REPRODUCTION AND DISCLOSURE PROHIBITED. MORPHO™ RAPID QUICK USER’S GUIDE Battery Battery Level Management Battery Icon The battery level is shown as a battery icon at the bottom of MAIN MENU. The battery levels are detailed in the following table: Icon MorphoRapID™ Use Battery Full optimal Good optimal Medium optimal Low works properly but should be charged soon Empty must be charged WARNING The fingerprint sensor may not be usable and captured data accuracy is no longer guaranteed. Terminal connected to the mains and charging 0000025754-07 - OCTOBER 2008 SAGEM SÉCURITÉ DOCUMENT - REPRODUCTION AND DISCLOSURE PROHIBITED. MORPHO™ RAPID QUICK USER’S GUIDE Battery Battery Level Battery Level Percentage Check To check the battery level, proceed as follows: Screen Action Start the MorphoRapID™ terminal. Press, SETTINGS then POWER. Check the battery level. → Proceed to charging the battery if needed. Click 10 to go back to the MAIN MENU. 0000025754-07 - OCTOBER 2008 SAGEM SÉCURITÉ DOCUMENT - REPRODUCTION AND DISCLOSURE PROHIBITED. MORPHO™ RAPID QUICK USER’S GUIDE Recommendations Power Management Description POWER MANAGEMENT provides a means of: •knowing battery power level, •setting power saving, •setting terminal back light. NOTE NOTE The terminal backlight setting can also be accessed by clicking on the Sagem Sécurité logo at the bottom left corner of the screen. The terminal backlight setting can also be accessed by pressing twice the Orange key and then the ESC key ♦ Press the key as many times as needed to adjust backlight. 5. Re co m me n d a tion s General Precautions WARNING The manufacturer cannot be held responsible if the above recommendations are not followed or if the Sagem Sécurité MorphoRapID™ is used incorrectly. – Do not attempt to repair your Sagem Sécurité MorphoRapID™ yourself. The manufacturer cannot be held responsible for any damage/accident that may result from attempts to repair components. – Any work carried out by non-authorized personnel will invalidate your warranty. – Do not expose your Sagem Sécurité MorphoRapID™ to extreme temperatures. – Attempts to integrate the MorphoRapID™ with unapproved accessories will void your warranty. – The MorphoRapID™ is not waterproof: Do not attempt to immerse 0000025754-07 - OCTOBER 2008 SAGEM SÉCURITÉ DOCUMENT - REPRODUCTION AND DISCLOSURE PROHIBITED. 11 MORPHO™ RAPID QUICK USER’S GUIDE Battery it. Areas Containing Combustibles It is strongly recommended not to install the Sagem Sécurité MorphoRapID™ in the vicinity of gas stations, petroleum processing facilities or any other facility containing flammable or combustible gas or materials. 12 0000025754-07 - OCTOBER 2008 SAGEM SÉCURITÉ DOCUMENT - REPRODUCTION AND DISCLOSURE PROHIBITED.
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.4 Linearized : No Page Count : 12 Producer : GPL Ghostscript 8.54 Create Date : 2008:11:26 16:29:38+01:00 Modify Date : 2008:11:26 16:29:38 Title : QUICK MR1100 User Guide Creator : PDFCreator Version 0.9.3 Author : g008037 Subject :EXIF Metadata provided by EXIF.tools