130604 1 Sta Rite Ssj Series Brochure User Manual

User Manual: Pump 130604 1 Sta-Rite Ssj Series Brochure

Open the PDF directly: View PDF PDF.
Page Count: 4

Download130604 1 Sta-Rite Ssj Series Brochure User Manual
Open PDF In BrowserView PDF
STA-RITE SSJ Series
®

Cast iron vertical jet pumps

FEATURES
Automatic Pressure Regulator: Fasteracting, quieter design eliminates “hunting”
for correct drive pressure. New, improved
stem and guide are precisely molded to
assure efficient, trouble-free performance
on all deep wells.
Quality Construction: Precisionmachined, close-grained cast iron pump
body and base are specially treated to
resist corrosion.
Noryl Impellers: Precision-molded for
perfect balance, and ultra-smooth for
highest performance and efficiency.
Pressure Switch: High quality. Differential
and cut-in/cut-out pressure settings
are adjustable.
The SSJ Series Vertical Jet Pumps are

Applications

the industry standard deep well jet

Water systems and sprinkling…for
homes, farms and cottages.

pumps for over-the-well
“bolt-on” installations.

SPECIFICATIONS

The SSJ Series Jet Pumps include the

Body: Rugged cast iron

pre-plumbed external automatic

Pump and Motor Shaft: Stainless steel

regulator, pressure gauge, pressure

Impellers: Noryl®

switch, and a complete line of casing
2" and 3" single pipe jet packages.

ORDERING INFORMATION
CATALOG
NUMBER

HP

DESCRIPTION

ssjc
ssjd
ssje

1/2
3/4
1

Deep Well Jet
Deep Well Jet
Deep Well Jet

PIPE TAPPING SIZES
SUCT. DRIVE DISCH.
1-1/4"
1-1/4"
1-1/4"

1"
1"
1"

1"
1"
1"

Motor Windings: Superior insulation
materials protect against exces­sive
moisture and contaminants to ensure
prolonged motor life.
Balanced Rotor: Diecast under high
pressures for uniform performance and
greater efficiency...dynamically balanced.

Diffuser: Heavy-duty cast iron

adapters to drive the 4" double pipe or

Dustproof Cover: All electrical
components are protected from dirt,
dust and insects by a dustproof canopy.
Ventilating air cannot contaminate vital
switching components. This eliminates
the most common cause of motor failure.

MOTOR
VOLTAGE

APPROX. WT.
LBS.

115/230
115/230
115/230

53
63
65

Heavy-Duty Ball Bearings: Shielded,
permanently lubricated bearings are
extensively tested to ensure extended life
and smooth, quiet operation.
Pump and Motor Shaft: Stainless steel for
maximum corrosion resistance; one-piece
threaded shaft for positive impeller drive
and alignment.

adapter flange*

CATALOG
NUMBER
j216-26

DESCRIPTION

used with

1-1/4" x 1"

Offset single pipe and 4" double pipe

*Required for all 4" double pipe or offset installations.
NOTE: Order pump from ordering information table above. A Jet Package should be ordered with every SSJ Series Pump. All installations require an appropriate
size adapter flange or casing adapter.
Noryl® is registered trademark of General Electric Co.
All other brand or product names are trademarks or registered trademarks of Pentair Ltd.

1

s4512ws

STA-RITE SSJ Series
®

Cast iron vertical jet pumps
OUTLINE DIMENSIONs

Cat. No.

A

ssjc

14-1/2

ssjd

15-1/8

ssje

16-3/16

A

3/8
8-1/8
12-1/4
SSJ

Dimensions (in inches) are for estimating purposes only.

PUMP PERFORMANCe (Capacity in Gallons Per Minute)
DEEP WELL (40 PSI) 4" double PIPE

max. pump
shut-off press.
psi

PUMPING DEPTH IN FEET
Cat.
no.

hp

ssjc 1/2

ssjd 3/4

ssje

1

JET
NO.

USES
VENTURI

USES
NOZZLE

15SD

J32P-18

J34P-42

CK4

J32P-32

J34P-35

20'
9.5

30'

40'

50'

60'

70'

80'

90'

100' 110' 120' 130'

4.8

4.3

3.7

3.0

2.4

1.8

1.5

1.0

7.0

4.5

2.0

4SD

J32P-24

J34P-41

6.5

5.1

4.0

3.0

1.8

0.8

CK1

J32P-22

J34P-43

8.3

7.4

6.3

5.3

3.8

3.5

CK3

J32P-32

J34P-41

10.0

6.4

3.0

4SD

J32P-24

J34P-41

8.6

7.5

6.5

5.2

4.0

2.9

1.8

0.8

CK1

J32P-22

J34P-43

8.6

7.8

6.6

5.6

4.5

3.6

2.8

2.3

CK4

J32P-28

J34P-45

11.4 10.7

9.6

8.3

7.0

5.0

3.3

1.6

CK4

J32P-38

J34P-45

5.8

2.2

17.0 13.2

9.5

2.6

1.8

0.5

1.0

1.7

1.1

0.6

jet at
min.
depth

jet at
max.
depth

91

50

62

44

75

45

88

46

57

46

93

51

98

47

102

48

66

44

Tested and rated in accordance with Water Systems Council Standards.
NOTE: Pumps installed with a Pro-Source® tank require a 100 PSI relief valve. Pumps installed with a conventional tank require a 75 PSI relief valve.
Relief valve must be capable of relieving entire flow of pump at relief pressure.

2

s4512ws

STA-RITE SSJ Series
®

Cast iron vertical jet pumps

PUMP PERFORMANCe (Capacity in Gallons Per Minute)
DEEP WELL (40 PSI) 2" single PIPE

max. pump
shut-off press.
psi

PUMPING DEPTH IN FEET
Cat.
no.

ssjc

ssjd

ssje

hp

1/2

3/4

1

JET
NO.

USES
VENTURI

USES
NOZZLE

20'

30'

40'

14AP

J32P-32

J34P-45

9.2

6.7

4.3

10AP

J32P-24

J34P-44

6.2

4.8

3.7

2.3

1.2

8AP

J32P-18

J34P-42

4.1

3.7

3.1

2.6

2.1

15AP

J32P-33

J34P-41

9.2

5.7

9AP

J32P-29

J34P-44

10.6

7.4

4.7

2.3

8AP

J32P-18

J34P-42

5.0

4.7

4.2

3.8

16AP

J32P-38

J34P-45

15.3 11.8

8.5

5.2

9AP

J32P-29

J34P-44

12.3

9.3

6.4

4.0

8AP

J32P-18

J34P-42

5.7

5.0

4.6

4.2

3.7

3.3

12.3

50'

60'

70'

3.3

80'

1.6

3.3

90'

1.2

2.3

2.8

100' 110' 120' 130'

0.8

1.8

2.4

1.3

1.8

1.3

jet at
min.
depth

jet at
max.
depth

61

49

71

47

94

53

57

48

64

47

109

62

65

48

72

53

124

66

75

45

91

50

62

44

58

49

93

51

66

48

88

46

105

69

98

47

66

44

DEEP WELL (40 PSI) 3" single PIPE
ssjc

ssjd

ssje

1/2

3/4

1

19CP

J32P-24

J34P-41

6.5

5.1

4.0

3.0

1.8

0.8

16CP

J32P-18

J34P-42

4.8

4.3

3.7

3.0

2.4

1.8

11CP

J32P-32

J34P-45

9.5

7.0

4.5

2.0

26CP

J32P-33

J34P-41

13.0

9.8

6.0

19CP

J32P-24

J34P-41

8.6

7.5

6.5

5.2

17CP

J32P-29

J34P-44

11.5

8.0

5.2

2.6

15CP

J32P-22

J34P-43

8.3

7.4

6.3

5.3

3.8

3.5

2.6

19CP

J32P-24

J34P-41

7.9

7.5

7.2

6.5

5.6

4.4

2.8

15CP

J32P-22

J34P-43

8.6

7.8

6.6

5.6

4.5

3.6

2.8

10CP

J32P-38

J34P-45

17.0 13.2

9.5

5.8

2.2

4.0

2.9

1.5

1.8

1.0

0.5

0.8

1.8

2.3

0.1

1.7

1.1

0.6

Tested and rated in accordance with Water Systems Council Standards.
NOTE: Pumps installed with a Pro-Source® tank require a 100 PSI relief valve. Pumps installed with a conventional tank require a 75 PSI relief valve.
Relief valve must be capable of relieving entire flow of pump at relief pressure.

3

s4512ws

293 WRIGHT STREET, DELAVAN, WI 53115 WWW.STA-RITE.COM PH: 888-782-7483 ORDERS FAX: 800-426-9446
Because we are continuously improving our products and services, Pentair reserves the right to change specifications without prior notice.

s4512ws (05/20/13)



Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.6
Linearized                      : No
Create Date                     : 2013:05:24 08:14:14-05:00
Modify Date                     : 2013:05:24 08:14:14-05:00
XMP Toolkit                     : Adobe XMP Core 5.2-c001 63.139439, 2010/09/27-13:37:26
Metadata Date                   : 2013:05:24 08:14:14-05:00
Format                          : application/pdf
Document ID                     : uuid:dddde738-1d41-e244-8de4-f87ebcfdcad5
Instance ID                     : uuid:0c542f9a-5e0b-6445-824b-c26e4e489717
Page Count                      : 4
EXIF Metadata provided by EXIF.tools

Navigation menu