1011020G.TB Wiring Instr.pmd 550334 4 SJE Rhombus Tank Alert XT Terminal Block Instructions
: Pump 550334 4 Sje Rhombus Tank Alert Xt Terminal Block Wiring Instructions 550334_4_SJE Rhombus Tank Alert XT Terminal Block Wiring Instructions pdf
Open the PDF directly: View PDF .
Page Count: 2
Download | |
Open PDF In Browser | View PDF |
Tank Alert® XT Indoor/Outdoor Alarm Terminal Block Option Wiring Instructions INSTALL THE FLOAT SWITCH AND ALARM ELECTRICAL SHOCK HAZARD Disconnect power before installing or servicing this product. A qualified service person must install and service this product according to national and local electrial codes. Do not install in hazardous locations as defined by the National Electrical Code, ANSI/NFPA 70. ® Follow Tank Alert XT Indoor/Outdoor Alarm Installation Instructions included. INSTALL THE PUMP SWITCH NOTE: Electrical rating of pump must not exceed 20 amps at 120 VAC or 20 amps at 230 VAC. 1. Follow mounting instructions included with pump switch. 2. Determine the type of pump switch to be installed. Select the installation diagram from Figure A that corresponds to the type of pump switch being installed. Run wires from pump switch through conduit as shown in Figure A: Two-Wire Pump Switch Wiring: Using positions on the right side of the terminal block, connect the black wire to position 6, the white wire to position 7 as shown in Figure A (left diagram). ® Double Float Wiring: Using positions on the right side of the terminal block, connect the black wire to position 6, the white wire to position 5, the red wire to position 7 as shown in Figure A (right diagram). NOTE: Route pump power and alarm power cords through conduit on left. Route control switch, pump switch, and pump cords through conduit on right. FIGURE A 2-WIRE PUMP SWITCH OR DOUBLE FLOAT® PUMP SWITCH WIRE SIZE 12-24 AWG INSTALL THE PUMP 1. Run wires from pump through the same conduit as the pump switch wiring as shown in Figure B. 2. On the left side of the terminal block, connect the black wire to position 7, and on the right side of the terminal, connect the white wire to position 5, and the green wire to position 8 as shown in Figure B. 3. Run wires from pump power source through conduit as shown in Figure C. This source should be on a separate circuit from alarm power. 4. Using positions on the left side of the terminal block, connect the white wire to terminal position 5, the black wire to terminal position 6, and the green wire to terminal position 8 as shown in Figure C. 5. Turn power on and tip pump switch to check installation. Turn power off. 6. Finish installing alarm panel according to Tank Alert® XT Installation Instructions. FIGURE B FIGURE C WIRE SIZE 12-24 AWG WIRE SIZE 12-24 AWG NOTES: _______________________________________________________________________________________________ _______________________________________________________________________________________________________ _______________________________________________________________________________________________________ _______________________________________________________________________________________________________ _______________________________________________________________________________________________________ _______________________________________________________________________________________________________ _______________________________________________________________________________________________________ _______________________________________________________________________________________________________ _______________________________________________________________________________________________________ _______________________________________________________________________________________________________ _______________________________________________________________________________________________________ _______________________________________________________________________________________________________ _______________________________________________________________________________________________________ _______________________________________________________________________________________________________ _______________________________________________________________________________________________________ _______________________________________________________________________________________________________ _______________________________________________________________________________________________________ _______________________________________________________________________________________________________ _______________________________________________________________________________________________________ _______________________________________________________________________________________________________ _______________________________________________________________________________________________________ _______________________________________________________________________________________________________ _______________________________________________________________________________________________________ _______________________________________________________________________________________________________ _______________________________________________________________________________________________________ _______________________________________________________________________________________________________ _______________________________________________________________________________________________________ _______________________________________________________________________________________________________ 22650 County Highway 6 P.O. Box 1708 1-888-DIAL-SJE (1-888-342-5753) Phone: 218-847-1317 Detroit Lakes, Minnesota 56502 USA Fax: 218-847-4617 E-mail: sje@sjerhombus.com Inst. Instr. PN1011020G © SJE-Rhombus Rev 04/08
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.4 Linearized : Yes XMP Toolkit : Adobe XMP Core 4.0-c316 44.253921, Sun Oct 01 2006 17:14:39 Creator Tool : PageMaker 7.0 Modify Date : 2008:06:25 11:30:32-05:00 Create Date : 2008:06:25 11:29:53-05:00 Metadata Date : 2008:06:25 11:30:32-05:00 Format : application/pdf Title : 1011020G.TB wiring instr.pmd Creator : Sharlene.Delaney Producer : Acrobat Distiller 8.1.0 (Windows) Document ID : uuid:90dcbdd3-45ba-45a1-9252-21b364299324 Instance ID : uuid:b1674bc1-d19f-4f62-8069-0dbd663fb170 Page Count : 2 Author : Sharlene.DelaneyEXIF Metadata provided by EXIF.tools