R tron SNIDEN30 iDen Mini Wireless Repeater User Manual

R-tron Inc. iDen Mini Wireless Repeater

Contents

Part 1

iDEN MINI (RSN-iDEN-30)User’s Manual GGGGR-tron Inc.
User’s Manual      -2- GRF EXPOSURE INFORMATION The antenna used for this transmitter must not exceed 7dBi and must be installed to provide a minimum separation distance of 22cm from all persons.CAUTIONThis equipment is indoor use and all the communication wiring are limited to inside of the building.
   iDEN MINI GUser’s Manual      -3- GThis document describes the specifications, installation and operation of iDEN MINI. Hardware and software mentioned in this document are subject to continuous development and improvement. Consequently, there may be minor discrepancies between the information in the document and the performance and design of the product. Specifications, dimensions and other statements mentioned in this document are subject to change without notice. R-tron Inc. 6402 College Boulevard Overland Park, KS 66211 Phone: +1-913-344-9977, 1-888-31R-TRON Fax: +1-913-344-9988 Internet: www.r-tron.comR-tron is registered trademarks of R-tron Inc. Other products and company names mentioned herein this manual might be trade marks or trade names of their respective owners. This document or parts of it may not be reproduced without the written permission of R-tron Inc. Infringements will be prosecuted. All rights reserved Copyright © R-tron Inc. 2000-2007
   iDEN MINI GUser’s Manual      -4- GContentsAbbreviations .................................................................................................................... 6G1.GIntroduction ........................................................................................................ 7G2.GDescription ..........................................................................................................  9G2.1GSystem Specifications ................................................................................................. 9G2.1.1.GElectrical Specifications .................................................................................... 9G2.1.2.GMechanical Specifications .............................................................................. 10G2.2GSub Unit Overview ..................................................................................................... 11GG2.2.1.GUDC Module ................................................................................................... 13G2.2.2.GMultiplexer ...................................................................................................... 14G2.2.3.GMCU (Main Control Unit) ................................................................................ 15G2.2.4.GPower Supply ................................................................................................. 16G2.2.5.GHPAs (High Power Amplifiers) ........................................................................ 17G3.GHardware Installation .......................................................................................... 18G3.1GCheck List of Items .................................................................................................... 18G3.2GMounting ....................................................................................................................  19G3.3GGrounding ..................................................................................................................  20G3.4GRF Cable Connection ................................................................................................ 20G3.5GPower Up ................................................................................................................... 21G4.GCommand and Control through the Hyper Terminal ................................................22G4.1 Setting for Command and Control through the Hyper Terminal ..................................... 22G4.2 Command and Control through the Hyper Terminal ...................................................... 26G4.3 Downloading of the latest firmware ................................................................................ 32G5.GTroubleshooting .................................................................................................. 37G5.1GRF Connection Check ............................................................................................... 37G5.2GPower Connection ..................................................................................................... 37G5.3GRed Light on the Alarm LED ...................................................................................... 38G6.GGlossary .............................................................................................................40G6.1GALC (Automatic Level Control) ..................................................................................  40G6.2GASD (Automatic Shutdown) ....................................................................................... 40G
   iDEN MINI GUser’s Manual      -5- GFiguresFigure 1.GR-tron iDEN MINI .................................................................................................... 7GFigure 2.GOverview: Service .................................................................................................... 8GFigure 3.GDimension of iDEN MINI ........................................................................................ 10GFigure 4.GInternal View of iDEN MINI .................................................................................... 11GFigure 5.GBlock Diagram ....................................................................................................... 12GFigure 6.GUDC Module .......................................................................................................... 13GFigure 7.GMultiplexer ............................................................................................................ 14GFigure 8.GMain Control Unit .................................................................................................. 15GFigure 9.GPower Supply ........................................................................................................ 16GFigure 10.GHPA(High Power Amplifier) ..................................................................................... 17GFigure 11.GItems ................................................................................................................... 18GFigure 12.GMounting .............................................................................................................. 19GFigure 13.GGrounding ............................................................................................................ 20GFigure 14.GConfiguration: RF Cable Connection ........................................................................ 21GFigure 15.GPower Cord Connection .......................................................................................... 21GFigure 16.GLocal connection to the iDEN MINI .......................................................................... 22GFigure 17.GLEDs Off ............................................................................................................... 37GFigure 18.GAC power cord Check ............................................................................................. 38GFigure 19.GRed Light on Alarm LED ......................................................................................... 38G
   iDEN MINI GUser’s Manual      -6- GAbbreviationsAbbreviations used in this manual, in iDEN MINI. AC    Alternating Current ALC        Automatic Level Control ANT   Antenna ASD        Automatic Shutdown CDMA    Code Division Multiple Access DC    Direct Current  GND   Grounding GUI   Graphic User Interface iDEN  Integrated Digital Enhanced NetworkLED    Light Emitting Diode PSU    Power Supply Unit RF    Radio Frequency TEMP   Temperature VSWR    Voltage Standing Wave Ratio
   iDEN MINI GUser’s Manual      -7- G1. Introduction Figure 1.  R-tron iDEN MINI iDEN MINI repeater is used to fill out areas in iDEN mobile systems, such as base station fringe areas, business and industrial buildings, etc. iDEN MINI receives signals from a base station, amplifies and retransmits the signals to mobile stations. Also it receives, amplifies and retransmits signals in the opposite direction. Both directions are served simultaneously with the following features: 7MHz or 18MHz-bandwidth service @ 800MHz’s 5MHz-bandwidth service @ 900MHz’s Band Shifting @ 800MHz’s and 900MHz’s Roll Offs: 65 dBc at 0.5MHz outside pass-band
   iDEN MINI GUser’s Manual      -8- G.GGFigure 2.  Overview: Service
   iDEN MINI GUser’s Manual      -9- G2. Description 2.1 System Specifications 2.1.1. Electrical  Specifications Parameter iDEN 800  iDEN 900 Selectable Bandwidth  DL & UL  In-band BW:18M In-band BW:7.0M  In-band BW:5M Frequency Selection    DL 18MHz-bandwidth851~869MHz 850.8~868.8MHz 850.6~868.6MHz 7MHz-bandwidth862~869MHz 861.8~868.8MHz 861.6~868.6MHz 5MHz-bandwidth935~940MHz 934.8~939.8MHz 934.6~939.6MHz UL 18MHz-bandwidth806~824MHz 805.8~823.8MHz 805.6~823.6MHz 7MHz-bandwidth817~824MHz 816.8~823.8MHz 816.6~823.6MHz 5MHz-bandwidth896~901MHz 895.8~900.8MHz 895.6~900.6MHz Roll off  DL & UL  ˺65dBc @Fedge+/-500KHz˺65dBc @Fedge+/-500KHz Gain ripple  ·1.5dB (Typical) Gain  DL & UL  50dB to 80dB OutputPower DL & UL  30dBm Delay  DL & UL  8.0µs Max. VSWR  DL & UL  1.5Max. Rx  Noise Figure 5dB Max. (80dB Gain) 12dB Max. (50dB Gain) Input Range DL & UL  -30dBm Max. Power supply  110V~125V, 60Hz typical Operating temperature  *-10¶j~50¶CVX[¶m¥XYY¶mStorage temperature  -20¶C~60¶C/-4¶F~140¶FConsumption power  112.2W
   iDEN MINI GUser’s Manual      -10- G2.1.2. Mechanical  Specifications Parameter Specification RF connectors  N-female x 2, SMA-female x 4 Size  20.87 X 14.01 X 8.66(Inch),   530 X 356 X 220(mm) Weight 24kg (52.912lbs) LANALARMAC IN110 -125V ~ڟڜکڢڠڭڭڤڮڦٻڪڡٻڠڧڠڞگڭڤڞٻڮڣڪڞڦBRACKETmay not harmful interference.RSN-iDEN-30COMPLIES WITH PART 90, FCC RULES.110 -125V ~ , 60Hz , 4A:PRODUCT PART NUMBERPOWER     :FCC REG. NO.  :  STESNiDEN30SERIAL NO.  /  DATE  :  E25810931CYI.T.E:MAKER     MADE I N KOREAR-tron lnc.Operation is subject to the condition that this deviceThis device complies with Part 15 of the FCC Rules.800MHzTX MON.900MHzRX MON.DONORANTENNASERVICEANTENNA900MHzTX MON.800MHzRX MON.Figure 3.  Dimension of iDEN MINI
   iDEN MINI GUser’s Manual      -11- G2.2  Sub Unit Overview iDEN MINI is composed of the following sub units: UDC(Up Down Converter) HPAs(High Power Amplifiers) MultiplexerMain Control Unit (MCU) Power Supply Unit (PSU) EMI Filter Figure 4.  Internal View of iDEN MINI
   iDEN MINI GUser’s Manual      -13- G2.2.1. UDC  Module The UDC Module is basically a bi-directional amplifier that sharply filters out unwanted noise. Figure 6.  UDC Module
   iDEN MINI GUser’s Manual      -14- G2.2.2. Multiplexer A multiplexer is a device that combines two or more signals onto a common channel or medium to increase its transmission efficiency. Figure 7.  Multiplexer

Navigation menu