R tron SNIDEN30 iDen Mini Wireless Repeater User Manual
R-tron Inc. iDen Mini Wireless Repeater
R tron >
Part 1
iDEN MINI (RSN-iDEN-30) User’s Manual R-tron Inc. RF EXPOSURE INFORMATION The antenna used for this transmitter must not exceed 7dBi and must be installed to provide a minimum separation distance of 22cm from all persons. CAUTION This equipment is indoor use and all the communication wiring are limited to inside of the building. User’s Manual -2- iDEN MINI This document describes the specifications, installation and operation of iDEN MINI. Hardware and software mentioned in this document are subject to continuous development and improvement. Consequently, there may be minor discrepancies between the information in the document and the performance and design of the product. Specifications, dimensions and other statements mentioned in this document are subject to change without notice. R-tron Inc. 6402 College Boulevard Overland Park, KS 66211 Phone: +1-913-344-9977, 1-888-31R-TRON Fax: +1-913-344-9988 Internet: www.r-tron.com R-tron is registered trademarks of R-tron Inc. Other products and company names mentioned herein this manual might be trade marks or trade names of their respective owners. This document or parts of it may not be reproduced without the written permission of R-tron Inc. Infringements will be prosecuted. All rights reserved Copyright © R-tron Inc. 2000-2007 User’s Manual -3- iDEN MINI Contents Abbreviations .................................................................................................................... 6G 1.G Introduction ........................................................................................................ 7G 2.G Description .......................................................................................................... 9G 2.1G System Specifications ................................................................................................. 9G 2.1.1.G Electrical Specifications .................................................................................... 9G 2.1.2.G Mechanical Specifications .............................................................................. 10G 2.2G Sub Unit Overview..................................................................................................... 11G 2.2.1.G UDC Module ................................................................................................... 13G 2.2.2.G Multiplexer ...................................................................................................... 14G 2.2.3.G MCU (Main Control Unit) ................................................................................ 15G 2.2.4.G Power Supply ................................................................................................. 16G 2.2.5.G HPAs (High Power Amplifiers) ........................................................................ 17G 3.G Hardware Installation ..........................................................................................18G 3.1G 3.2G 3.3G 3.4G 3.5G 4.G Check List of Items .................................................................................................... 18G Mounting .................................................................................................................... 19G Grounding .................................................................................................................. 20G RF Cable Connection ................................................................................................ 20G Power Up ................................................................................................................... 21G Command and Control through the Hyper Terminal ................................................22G 4.1 Setting for Command and Control through the Hyper Terminal ..................................... 22G 4.2 Command and Control through the Hyper Terminal ...................................................... 26G 4.3 Downloading of the latest firmware ................................................................................ 32G 5.G Troubleshooting ..................................................................................................37G 5.1G 5.2G 5.3G 6.G RF Connection Check ............................................................................................... 37G Power Connection ..................................................................................................... 37G Red Light on the Alarm LED ...................................................................................... 38G Glossary .............................................................................................................40G 6.1G 6.2G User’s Manual ALC (Automatic Level Control) .................................................................................. 40G ASD (Automatic Shutdown)....................................................................................... 40G -4- iDEN MINI Figures Figure Figure Figure Figure Figure Figure Figure Figure Figure Figure Figure Figure Figure Figure Figure Figure Figure Figure Figure 1.G R-tron iDEN MINI .................................................................................................... 7G 2.G Overview: Service.................................................................................................... 8G 3.G Dimension of iDEN MINI ........................................................................................ 10G 4.G Internal View of iDEN MINI .................................................................................... 11G 5.G Block Diagram ....................................................................................................... 12G 6.G UDC Module .......................................................................................................... 13G 7.G Multiplexer ............................................................................................................ 14G 8.G Main Control Unit .................................................................................................. 15G 9.G Power Supply ........................................................................................................ 16G 10.G HPA(High Power Amplifier)..................................................................................... 17G 11.G Items ................................................................................................................... 18G 12.G Mounting .............................................................................................................. 19G 13.G Grounding ............................................................................................................ 20G 14.G Configuration: RF Cable Connection ........................................................................ 21G 15.G Power Cord Connection .......................................................................................... 21G 16.G Local connection to the iDEN MINI .......................................................................... 22G 17.G LEDs Off ............................................................................................................... 37G 18.G AC power cord Check............................................................................................. 38G 19.G Red Light on Alarm LED ......................................................................................... 38G User’s Manual -5- iDEN MINI Abbreviations Abbreviations used in this manual, in iDEN MINI. AC ALC ANT ASD CDMA DC GND GUI iDEN LED PSU RF TEMP VSWR User’s Manual Alternating Current Automatic Level Control Antenna Automatic Shutdown Code Division Multiple Access Direct Current Grounding Graphic User Interface Integrated Digital Enhanced Network Light Emitting Diode Power Supply Unit Radio Frequency Temperature Voltage Standing Wave Ratio -6- iDEN MINI 1. Introduction Figure 1. R-tron iDEN MINI iDEN MINI repeater is used to fill out areas in iDEN mobile systems, such as base station fringe areas, business and industrial buildings, etc. iDEN MINI receives signals from a base station, amplifies and retransmits the signals to mobile stations. Also it receives, amplifies and retransmits signals in the opposite direction. Both directions are served simultaneously with the following features: User’s Manual 7MHz or 18MHz-bandwidth service @ 800MHz’s 5MHz-bandwidth service @ 900MHz’s Band Shifting @ 800MHz’s and 900MHz’s Roll Offs: 65 dBc at 0.5MHz outside pass-band -7- iDEN MINI .G Figure 2. User’s Manual Overview: Service -8- iDEN MINI 2. Description 2.1 System Specifications 2.1.1. Electrical Specifications Parameter Selectable Bandwidth DL & UL 18MHzbandwidth DL 7MHzbandwidth 18MHzbandwidth UL 7MHzbandwidth 5MHzbandwidth Roll off DL & UL Gain ripple Output Power Delay VSWR User’s Manual In-band BW:18M In-band BW:7.0M In-band BW:5M 851~869MHz 850.8~868.8MHz 850.6~868.6MHz 862~869MHz 861.8~868.8MHz 861.6~868.6MHz 935~940MHz 934.8~939.8MHz 934.6~939.6MHz 806~824MHz 805.8~823.8MHz 805.6~823.6MHz 817~824MHz 816.8~823.8MHz 816.6~823.6MHz 896~901MHz 895.8~900.8MHz 895.6~900.6MHz ˺65dBc ˺65dBc @Fedge+/-500KHz @Fedge+/-500KHz ·1.5dB (Typical) DL & UL 50dB to 80dB DL & UL 30dBm DL & UL DL & UL 8.0µs Max. 1.5Max. Rx Noise Figure Input Range iDEN 900 5MHzbandwidth Frequency Selection Gain iDEN 800 DL & UL 5dB Max. (80dB Gain) 12dB Max. (50dB Gain) -30dBm Max. Power supply 110V~125V, 60Hz typical Operating temperature Storage temperature Consumption power *-10¶j~50¶CVX[¶m¥XYY¶m -20¶C~60¶C/-4¶F~140¶F 112.2W -9- iDEN MINI 2.1.2. Mechanical Specifications Parameter RF connectors Specification N-female x 2, SMA-female x 4 20.87 X 14.01 X 8.66(Inch), 530 X 356 X 220(mm) 24kg (52.912lbs) Size MADE IN KOREA : R-tron lnc. This device complies with Part 15 of the FCC Rules. Operation is subject to the condition tha t this device may not harmful interference. MAKER PRODUCT PART NUMBER : RSN-iDEN-30 POWER : 110 -125V ~ , 60Hz , 4A COMPLIES WITH PART 90, FCC RULES. FCC REG. NO. : STESNiDEN30 SERIAL NO. / DATE : E258109 I.T.E 31CY Weight BRACKET 800MHz RX MON. 900MHz TX MON. 900MHz RX MON. 800MHz TX MON. DONOR ANTENNA AC IN 110 -125V ~ ALARM SERVICE ANTENNA LAN ڭڠڢکڜڟ ڦڞڪڣڮٻڞڤڭگڞڠڧڠٻڡڪٻڦڮڤڭ Figure 3. User’s Manual Dimension of iDEN MINI -10- iDEN MINI 2.2 Sub Unit Overview iDEN MINI is composed of the following sub units: UDC(Up Down Converter) HPAs(High Power Amplifiers) Multiplexer Main Control Unit (MCU) Power Supply Unit (PSU) EMI Filter Figure 4. User’s Manual Internal View of iDEN MINI -11- iDEN MINI 2.2.1. UDC Module The UDC Module is basically a bi-directional amplifier that sharply filters out unwanted noise. Figure 6. User’s Manual UDC Module -13- iDEN MINI 2.2.2. Multiplexer A multiplexer is a device that combines two or more signals onto a common channel or medium to increase its transmission efficiency. Figure 7. User’s Manual Multiplexer -14-
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.4 Linearized : No Page Count : 13 XMP Toolkit : XMP toolkit 2.9.1-13, framework 1.6 About : uuid:a18744ee-f2cd-4817-83c1-34eea93f9abd Producer : Acrobat Distiller 6.0 (Windows) Create Date : 2007:05:21 12:47:52+09:00 Modify Date : 2007:05:21 12:47:52+09:00 Document ID : uuid:00387aec-9956-4157-8c37-455da74e5b48 Format : application/pdf Title : untitledEXIF Metadata provided by EXIF.tools