RELM Communications RPV516A VHF FM Transceiver User Manual RPV516A SAR Test Report revised 121901
RELM Communications Inc VHF FM Transceiver RPV516A SAR Test Report revised 121901
Contents
- 1. Users Manual
 - 2. Revised Manual 121901
 - 3. Revised Manual 010402
 
Revised Manual 121901
CELLTECH RESEARCH INC. 1955 Moss Court, Kelowna B.C. Canada V1Y 9L3 Test Report S/N: 092601-169ARU Date of Tests: October 16, 2001 FCC SAR Evaluation _________________________________________________________________________________________________________ CERTIFICATE OF COMPLIANCE SAR EVALUATION Test Lab: Applicant Information: CELLTECH RESEARCH INC. Testing and Engineering Lab 1955 Moss Court Kelowna, B.C. Canada V1Y 9L3 Phone: 250 - 860-3130 Fax: 250 - 860-3110 Toll Free: 1-877-545-6287 e-mail: info@celltechlabs.com web site: www.celltechlabs.com RELM WIRELESS CORPORATION 7100 Technology Drive West Melbourne, FL 32904 FCC Rule Part(s): FCC ID: Model(s): EUT Type: Modulation: Tx Frequency Range: Conducted Power Tested: Antenna Type: Battery Type: Body-Worn Accessory: 2.1093; ET Docket 96-326 ARURPV516A RPV516A Portable VHF PTT Radio Transceiver FM 150.05 - 173.95 MHz 5.3 Watts Helical Whip 7.2VDC, 1100mAh, Ni-Cd 1.4cm Belt-Clip This wireless portable device has been shown to be compliant for localized Specific Absorption Rate (SAR) for controlled environment/occupational exposure limits specified in ANSI/IEEE Std. C95.1-1992 and had been tested in accordance with the measurement procedures specified in ANSI/IEEE Std. C95.3-1999. I attest to the accuracy of data. All measurements were performed by me or were made under my supervision and are correct to the best of my knowledge and belief. I assume full responsibility for the completeness of these measurements and vouch for the qualifications of all persons taking them. Celltech Research Inc. certifies that no party to this application has been denied FCC benefits pursuant to Section 5301 of the Anti-Drug Abuse Act of 1988, 21 U.S.C. 853(a). Shawn McMillen General Manager Celltech Research Inc. © 2001 Celltech Research Inc. CELLTECH RESEARCH INC. 1955 Moss Court, Kelowna B.C. Canada V1Y 9L3 Test Report S/N: 092601-169ARU Date of Tests: October 16, 2001 FCC SAR Evaluation _________________________________________________________________________________________________________ TABLE OF CONTENTS 1.0 INTRODUCTION………………………………………………………… 2.0 DESCRIPTION OF EQUIPMENT UNDER TEST……………………. 3.0 SAR MEASUREMENT SYSTEM ……………………………………… 4.0 SAR MEASUREMENT SUMMARY…………………………………… 3-4 5.0 DETAILS OF SAR EVALUATION………………………………….…. 6.0 EVALUATION PROCEDURES……..………………………………….. 7.0 SYSTEM VALIDATION……………………………………………….... 8.0 TISSUE PARAMETERS………………………………………………… 9.0 SIMULATED TISSUES…………………………….……………………. 10.0 SAR SAFETY LIMITS…….…..………………………………………… 11.0 ROBOT SYSTEM SPECIFICATIONS.………………………………… 12.0 PROBE SPECIFICATION……………………………………………… 13.0 SAM PHANTOM…………………………………….….………………... 14.0 DEVICE HOLDER……………………………………..………………… 15.0 TEST EQUIPMENT LIST………………………………………..……… 10 16.0 MEASUREMENT UNCERTAINTIES…………………………………. 11 17.0 REFERENCES……………………………………………………………. 12 APPENDIX A - SAR MEASUREMENT DATA…………...……………………. APPENDIX B - DIPOLE VALIDATION………………………………………... APPENDIX C - PROBE CALIBRATION……………………………………….. APPENDIX D – DETERMINATION OF PROBE CONVERSION FACTORS APPENDIX E – SAR SENSITIVITIES…………………………………………... APPENDIX F - SAR TEST SETUP PHOTOGRAPHS………………...………. 13 14 15 16 17 18 © 2001 Celltech Research Inc. CELLTECH RESEARCH INC. Test Report S/N: 092601-169ARU Date of Tests: October 16, 2001 FCC SAR Evaluation 1955 Moss Court, Kelowna B.C. Canada V1Y 9L3 _________________________________________________________________________________________________________ 1.0 INTRODUCTION This measurement report shows compliance of the RELM WIRELESS CORP. Model: RPV516A Portable VHF PTT Radio Transceiver FCC ID: ARURPV516A with the regulations and procedures specified in FCC Part 2.1093, ET Docket 96-326 Rules (controlled exposure). The test procedures, as described in American National Standards Institute C95.1-1992 (1), and FCC OET Bulletin 65, Supplement C (Edition 01-01) (2) were employed. A description of the product and operating configuration, detailed summary of the test results, methodology and procedures used in the evaluation, equipment used, and the various provisions of the rules are included within this test report. 2.0 DESCRIPTION OF EQUIPMENT UNDER TEST (EUT) Rule Part(s) FCC 2.1093 ET Docket 96.326 Modulation FM EUT Type Portable VHF PTT Radio Transceiver Tx Frequency Range (MHz) 150.05 – 173.95 FCC ID ARURPV516A Conducted Power Tested 5.3 Watts Model No.(s) RPV516A Antenna Type(s) Helical Whip Serial No. Pre-production Power Supply Ni-Cd Battery (DC 7.2V 1100mAh) Front of EUT Back of EUT © 2001 Celltech Research Inc. Left Side of EUT Right Side of EUT EUT with Speaker/Mic RELM WIRELESS CORP. FCC ID: ARURPV516A Portable VHF PTT Radio Transceiver (150-174MHz) CELLTECH RESEARCH INC. Test Report S/N: 092601-169ARU Date of Tests: October 16, 2001 FCC SAR Evaluation 1955 Moss Court, Kelowna B.C. Canada V1Y 9L3 _________________________________________________________________________________________________________ 3.0 SAR MEASUREMENT SYSTEM Celltech Research SAR measurement facility utilizes the Dosimetric Assessment System (DASY™) manufactured by Schmid & Partner Engineering AG (SPEAG™) of Zurich, Switzerland. The DASY system is comprised of the robot controller, computer, near-field probe, probe alignment sensor, and the SAM phantom containing brain or body equivalent material. The robot is a six-axis industrial robot performing precise movements to position the probe to the location (points) of maximum electromagnetic field (EMF). A cell controller system contains the power supply, robot controller, teach pendant (Joystick), and remote control, is used to drive the robot motors. The Staubli robot is connected to the cell controller to allow software manipulation of the robot. A data acquisition electronic (DAE) circuit performs the signal amplification, signal multiplexing, ADconversion, offset measurements, mechanical surface detection, collision detection, etc. is connected to the Electro-optical coupler (EOC). The EOC performs the conversion from the optical into digital electric signal of the DAE and transfers data to the PC plug-in card. The DAE3 utilizes a highly sensitive electrometer-grade preamplifier with auto-zeroing, a channel and gain-switching multiplexer, a fast 16-bit AD-converter and a command decoder and control logic unit. Transmission to the PC-card is accomplished through an optical downlink for data and status information and an optical uplink for commands and clock lines. The mechanical probe-mounting device includes two different sensor systems for frontal and sidewise probe contacts. They are also used for mechanical surface detection and probe collision detection. The robot uses its own controller with a built in VME-bus computer. DASY3 SAR Measurement System with SAM phantom © 2001 Celltech Research Inc. RELM WIRELESS CORP. FCC ID: ARURPV516A Portable VHF PTT Radio Transceiver (150-174MHz) CELLTECH RESEARCH INC. Test Report S/N: 092601-169ARU Date of Tests: October 16, 2001 FCC SAR Evaluation 1955 Moss Court, Kelowna B.C. Canada V1Y 9L3 _________________________________________________________________________________________________________ 4.0 SAR MEASUREMENT SUMMARY The measurement results were obtained with the EUT tested in the conditions described in this report. Detailed measurement data and plots showing the maximum SAR location of the EUT are reported in Appendix A. Face-Held SAR Measurements Conducted Power (W) Antenna Position Separation Distance (cm) CW 5.3 Fixed Mid CW 5.3 High CW 5.3 Freq. (MHz) Channel 150.05 Low 162.50 173.95 Mode Mixture Type: Brain Dielectric Constant: 52.6 Conductivity: 0.76 SAR (w/kg) 100% Duty Cycle 50% Duty Cycle 2.5 0.374 0.187 Fixed 2.5 0.251 0.126 Fixed 2.5 0.138 0.069 ANSI / IEEE C95.1 1992 - SAFETY LIMIT Spatial Peak Controlled Exposure/Occupational BRAIN: 8.0 W/kg (averaged over 1 gram) Notes: 1. The SAR values found were below the maximum limit of 8.0 w/kg (controlled exposure). 2. The highest face-held SAR value found was 0.374 w/kg (100% duty cycle). 3. The EUT was tested for face-held SAR with a 2.5 cm separation distance between the front of the EUT and the outer surface of the planar phantom. 4. Ambient TEMPERATURE: 23.1 °C Relative HUMIDITY: 57.3 % Atmospheric PRESSURE: 100.2 kPa 5. Fluid Temperature ≈ 23 °C 6. During the entire test the conducted power was maintained to within 5% of the initial conducted power. Face-held SAR Test Setup 2.5cm Separation Distance © 2001 Celltech Research Inc. RELM WIRELESS CORP. FCC ID: ARURPV516A Portable VHF PTT Radio Transceiver (150-174MHz) CELLTECH RESEARCH INC. Test Report S/N: 092601-169ARU Date of Tests: October 16, 2001 FCC SAR Evaluation 1955 Moss Court, Kelowna B.C. Canada V1Y 9L3 _________________________________________________________________________________________________________ Body-Worn SAR Measurements SAR (w/kg) Conducted Power (W) Antenna Position Belt-Clip Separation Distance (cm) CW 5.3 Fixed 1.4 0.965 0.483 Mid CW 5.3 Fixed 1.4 0.645 0.323 High CW 5.3 Fixed 1.4 0.138 0.069 Freq. (MHz) Channel 150.05 Low 162.50 173.95 Mode Mixture Type: Body Dielectric Constant: 62.2 Conductivity: 0.80 100% Duty Cycle 50% Duty Cycle ANSI / IEEE C95.1 1992 - SAFETY LIMIT Spatial Peak Controlled Exposure/Occupational BODY: 8.0 W/kg (averaged over 1 gram) Notes: 1. The SAR values found were below the maximum limit of 8.0 w/kg (controlled exposure). 2. The highest body-worn SAR value found was 0.965 w/kg (100% duty cycle). 3. The EUT was tested for body-worn SAR with the attached belt-clip providing a 1.4cm separation distance between the back of the EUT and the outer surface of the planar phantom. 4. Ambient TEMPERATURE: 23.1 °C Relative HUMIDITY: 57.3 % Atmospheric PRESSURE: 100.2 kPa 5. Fluid Temperature ≈ 23 °C 6. During the entire test the conducted power was maintained to within 5% of the initial conducted power. Body-worn SAR Test Setup with 1.4cm Belt-Clip © 2001 Celltech Research Inc. RELM WIRELESS CORP. FCC ID: ARURPV516A Portable VHF PTT Radio Transceiver (150-174MHz) CELLTECH RESEARCH INC. Test Report S/N: 092601-169ARU Date of Tests: October 16, 2001 FCC SAR Evaluation 1955 Moss Court, Kelowna B.C. Canada V1Y 9L3 _________________________________________________________________________________________________________ 5.0 DETAILS OF SAR EVALUATION The RELM WIRELESS CORP. Model: RPV516A Portable VHF PTT Radio Transceiver FCC ID: ARURPV516A was found to be compliant for localized Specific Absorption Rate (Controlled Exposure) based on the following test provisions and conditions: 1. The EUT was tested in a face-held configuration with the front of the device placed parallel to the outer surface of the planar phantom and with a 2.5cm separation distance. 2. The EUT was tested in a body-worn configuration with the attached belt-clip touching the outer surface of the planar phantom and providing a 1.4cm separation distance between the back of the EUT and the outer surface of the planar phantom. 3. The EUT was evaluated for SAR at maximum power and the unit was operated for an appropriate period prior to the evaluation in order to minimize drift. The conducted power level was checked before and after each test. 4. The conducted power was measured according to the procedures described in FCC Part 2.1046. 5. The location of the maximum spatial SAR distribution (Hot Spot) was determined relative to the device and its antenna. 6. The EUT was tested with a fully charged battery. Note: Under continuous transmission the antenna became very warm and began to droop slightly. The device was cooled for brief periods during the evaluation in order to stabilize the antenna. The lower than expected SAR values reported for this particular EUT operating at the rated power levels can be attributed to excessive heating in the plastic antenna housing. 6.0 EVALUATION PROCEDURES The Specific Absorption Rate (SAR) evaluation was performed in the following manner: a. (i) The evaluation was performed in the applicable area of the phantom depending on the type of device being tested. For devices held to the ear during normal operation, both the left and right ear positions were evaluated in accordance with FCC OET Bulletin 65, Supplement C (Edition 01-01). (ii) For body-worn and face-held devices the planar section of the phantom was used. b. The SAR was determined by a pre-defined procedure within the DASY3 software. Upon completion of a reference and optical surface check, the exposed region of the phantom was scanned near the inner surface with a grid spacing of 20mm x 20mm. c. For frequencies below 500MHz a 4x4x7 matrix was performed around the greatest spatial SAR distribution found during the area scan of the applicable exposed region. For frequencies above 500MHz a 5x5x7 matrix was performed. SAR values were then calculated using a 3-D spline interpolation algorithm and averaged over spatial volumes of 1 and 10 grams. d. If the EUT had any appreciable drift over the course of the evaluation, then the EUT was reevaluated. Any unusual anomalies over the course of the test also warranted a re-evaluation. e. The E-field probe conversion factors outside the calibrated points were determined as follows: • In brain and body tissue between 750MHz and 1GHz, the conversion factor decreases approximately 1.3% per 100MHz frequency increase. • In brain and body tissue between 1.6GHz and 2GHz, the conversion factor decreases approximately 1% per 100MHz frequency increase. For body tissue around 900MHz (permittivity about 30% higher and conductivity about 15% higher than brain tissue): • The conversion factor in body tissue is approximately 3% lower than for brain tissue for the same frequency. © 2001 Celltech Research Inc. RELM WIRELESS CORP. FCC ID: ARURPV516A Portable VHF PTT Radio Transceiver (150-174MHz) CELLTECH RESEARCH INC. Test Report S/N: 092601-169ARU Date of Tests: October 16, 2001 FCC SAR Evaluation 1955 Moss Court, Kelowna B.C. Canada V1Y 9L3 _________________________________________________________________________________________________________ 7.0 SYSTEM VALIDATION Prior to the assessment, the system was verified in the planar section of the phantom with a 900MHz dipole for devices operating below 1GHz, and an 1800MHz dipole for devices operating above 1GHz. A forward power of 250mW was applied to the dipole and system was verified to a tolerance of +10%. The applicable verifications are as follows (see Appendix B for validation test plot): Dipole Validation Kit Target SAR 1g (w/kg) Measured SAR 1g (w/kg) D900V2 2.78 2.76 8.0 TISSUE PARAMETERS The dielectric parameters of the fluids were verified prior to the SAR evaluation using an 85070C Dielectric Probe Kit and an 8753E Network Analyzer. The dielectric parameters of the fluid are as follows: TISSUE PARAMETERS FOR DIPOLE VALIDATION Brain Equivalent Tissue Dielectric Constant εr Conductivity σ (mho/m) ρ (Kg/m3) 900MHz (Target) 41.5 ±5% 0.97 ±5% 1000 900MHz (Measured) 10/16/01 42.4 0.97 1000 BRAIN TISSUE PARAMETERS - EUT EVALUATION Equivalent Tissue Dielectric Constant εr Conductivity σ (mho/m) ρ (Kg/m3) 150MHz Brain (Target) 52.3 ±5% 0.76 ±5% 1000 150MHz Brain (Measured: 10/16/01) 52.6 0.76 1000 BODY TISSUE PARAMETERS - EUT EVALUATION Equivalent Tissue Dielectric Constant εr Conductivity σ (mho/m) ρ (Kg/m3) 150MHz Body (Target) 61.9 ±5% 0.80 ±5% 1000 150MHz Body (Measured: 10/16/01) 62.2 0.80 1000 © 2001 Celltech Research Inc. RELM WIRELESS CORP. FCC ID: ARURPV516A Portable VHF PTT Radio Transceiver (150-174MHz) CELLTECH RESEARCH INC. Test Report S/N: 092601-169ARU Date of Tests: October 16, 2001 FCC SAR Evaluation 1955 Moss Court, Kelowna B.C. Canada V1Y 9L3 _________________________________________________________________________________________________________ 9.0 SIMULATED TISSUES The brain and body mixtures consist of a viscous gel using hydroxethylcellulose (HEC) gelling agent and saline solution. Preservation with a bactericide is added and visual inspection is made to ensure air bubbles are not trapped during the mixing process. The fluid was prepared according to standardized procedures and measured for dielectric parameters (permitivity and conductivity). MIXTURE % INGREDIENT 900MHz Brain (Validation) 150MHz Brain 150MHz Body Water 51.07 38.35 46.6 Sugar 47.31 55.5 49.7 Salt 1.15 5.15 2.6 HEC 0.23 0.9 1.0 Bactericide 0.24 0.1 0.1 10.0 SAR SAFETY LIMITS SAR (W/Kg) EXPOSURE LIMITS (General Population / Uncontrolled Exposure Environment) (Occupational / Controlled Exposure Environment) Spatial Average (averaged over the whole body) 0.08 0.4 Spatial Peak (averaged over any 1g of tissue) 1.60 8.0 Spatial Peak (hands/wrists/feet/ankles averaged over 10g) 4.0 20.0 Notes: 1. Uncontrolled environments are defined as locations where there is potential exposure of individuals who have no knowledge or control of their potential exposure. 2. Controlled environments are defined as locations where there is potential exposure of individuals who have knowledge of their potential exposure and can exercise control over their exposure. © 2001 Celltech Research Inc. RELM WIRELESS CORP. FCC ID: ARURPV516A Portable VHF PTT Radio Transceiver (150-174MHz) CELLTECH RESEARCH INC. Test Report S/N: 092601-169ARU Date of Tests: October 16, 2001 FCC SAR Evaluation 1955 Moss Court, Kelowna B.C. Canada V1Y 9L3 _________________________________________________________________________________________________________ 11.0 ROBOT SYSTEM SPECIFICATIONS Specifications POSITIONER: Repeatability: No. of axis: Stäubli Unimation Corp. Robot Model: RX60L 0.02 mm Data Acquisition Electronic (DAE) System Cell Controller Processor: Pentium III Clock Speed: 450 MHz Operating System: Windows NT Data Card: DASY3 PC-Board Data Converter Features: Signal Amplifier, multiplexer, A/D converter, and control logic Software: DASY3 software Connecting Lines: Optical downlink for data and status info. Optical uplink for commands and clock PC Interface Card Function: 24 bit (64 MHz) DSP for real time processing Link to DAE3 16-bit A/D converter for surface detection system serial link to robot direct emergency stop output for robot E-Field Probe Model: Serial No.: Construction: Frequency: Linearity: ET3DV6 1590 Triangular core fiber optic detection system 10 MHz to 6 GHz ± 0.2 dB (30 MHz to 3 GHz) Phantom Type: Shell Material: Thickness: Volume: SAM V4.0C Fiberglass 2.0 ± 0.1 mm Approx. 20 liters © 2001 Celltech Research Inc. RELM WIRELESS CORP. FCC ID: ARURPV516A Portable VHF PTT Radio Transceiver (150-174MHz) CELLTECH RESEARCH INC. Test Report S/N: 092601-169ARU Date of Tests: October 16, 2001 FCC SAR Evaluation 1955 Moss Court, Kelowna B.C. Canada V1Y 9L3 _________________________________________________________________________________________________________ 12.0 PROBE SPECIFICATION (ET3DV6) Construction: Symmetrical design with triangular core Built-in shielding against static charges PEEK enclosure material (resistant to organic solvents, e.g. glycol) Calibration: In air from 10 MHz to 2.5 GHz In brain simulating tissue at frequencies of 900 MHz and 1.8 GHz (accuracy ± 8%) Frequency: 10 MHz to > 6 GHz; Linearity: ± 0.2 dB (30 MHz to 3 GHz) Directivity: ± 0.2 dB in brain tissue (rotation around probe axis) ± 0.4 dB in brain tissue (rotation normal to probe axis) Dynam. Rnge: 5 µW/g to > 100 mW/g; Linearity: ± 0.2 dB Srfce. Detect. ± 0.2 mm repeatability in air and clear liquids over diffuse reflecting surfaces Dimensions: Overall length: 330 mm Tip length: 16 mm Body diameter: 12 mm Tip diameter: 6.8 mm Distance from probe tip to dipole centers: 2.7 mm ET3DV6 E-Field Probe Application: General dosimetry up to 3 GHz Compliance tests of mobile phone 13.0 SAM PHANTOM V4.0C The SAM phantom V4.0C is a fiberglass shell phantom with a 2.0mm shell thickness for left and right head and flat planar area integrated in a wooden table. The shape of the fiberglass shell corresponds to the phantom defined by SCC34-SC2. The device holder positions are adjusted to the standard measurement positions in the three sections. SAM Phantom 14.0 DEVICE HOLDER The DASY3 device holder has two scales for device rotation (with respect to the body axis) and the device inclination (with respect to the line between the ear openings). The plane between the ear openings and the mouth tip has a rotation angle of 65°. The bottom plate contains three pair of bolts for locking the device holder. The device holder positions are adjusted to the standard measurement positions in the three sections. Device Holder © 2001 Celltech Research Inc. RELM WIRELESS CORP. FCC ID: ARURPV516A Portable VHF PTT Radio Transceiver (150-174MHz) CELLTECH RESEARCH INC. Test Report S/N: 092601-169ARU Date of Tests: October 16, 2001 FCC SAR Evaluation 1955 Moss Court, Kelowna B.C. Canada V1Y 9L3 _________________________________________________________________________________________________________ 15.0 TEST EQUIPMENT LIST SAR MEASUREMENT SYSTEM EQUIPMENT SERIAL NO. CALIBRATION DATE DASY3 System -Robot -ET3DV6 E-Field Probe -DAE -900MHz Validation Dipole -1800MHz Validation Dipole -SAM Phantom V4.0C 599396-01 1590 370 054 247 N/A N/A Mar 2001 Sept 1999 June 2001 June 2001 N/A 85070C Dielectric Probe Kit N/A N/A Gigatronics 8652A Power Meter -Power Sensor 80701A -Power Sensor 80701A 1835272 1833535 1833542 Oct 1999 Jan 2001 Feb 2001 E4408B Spectrum Analyzer US39240170 Nov 1999 8594E Spectrum Analyzer 3543A02721 Mar 2000 8753E Network Analyzer US38433013 Nov 1999 8648D Signal Generator 3847A00611 N/A 5S1G4 Amplifier Research Power Amplifier 26235 N/A © 2001 Celltech Research Inc. RELM WIRELESS CORP. FCC ID: ARURPV516A Portable VHF PTT Radio Transceiver (150-174MHz) 10 CELLTECH RESEARCH INC. Test Report S/N: 092601-169ARU Date of Tests: October 16, 2001 FCC SAR Evaluation 1955 Moss Court, Kelowna B.C. Canada V1Y 9L3 _________________________________________________________________________________________________________ 16.0 MEASUREMENT UNCERTAINTIES Uncertainty Description Error Distribution Weight Standard Deviation Axial isotropy ±0.2 dB U-Shaped 0.5 ±2.4 % Spherical isotropy ±0.4 dB U-Shaped 0.5 ±4.8 % Isotropy from gradient ±0.5 dB U-Shaped ± Spatial resolution ±0.5 % Normal ±0.5 % Linearity error ±0.2 dB Rectangle ±2.7 % Calibration error ±3.3 % Normal ±3.3 % ±1 % Rectangle ±0.6 % ELF and RF disturbances ±0.25 % Normal ±0.25 % Conductivity assessment ±5 % Rectangle ±5.8 % ±3 % Normal ±3 % ±0.1 mm Normal ±1 % Integrated and cube orientation ±3 % Normal ±3 % Cube Shape inaccuracies ±2 % Rectangle ±1.2 % Device positioning ±6 % Normal ±6 % Offset Probe Uncertainty SAR Evaluation Uncertainty Data acquisition error Spatial Peak SAR Evaluation Uncertainty Extrapolated boundary effect Probe positioning error Combined Uncertainties ±11.7 % ±5 % ±5 % Measurement uncertainties in SAR measurements are difficult to quantify due to several variables including biological, physiological, and environmental. According to ANSI/IEEE C95.3, the overall uncertainties are difficult to assess and will vary with the type of meter and usage situation. However, accuracy’s of ± 1 to 3 dB can be expected in practice, with greater uncertainties in near-field situations and at higher frequencies (shorter wavelengths), or areas where large reflecting objects are present. Under optimum measurement conditions, SAR measurement uncertainties of at least ± 2dB can be expected. According to CENELEC, typical worst-case uncertainty of field measurements is ± 5 dB. For well-defined modulation characteristics the uncertainty can be reduced to ± 3 dB. © 2001 Celltech Research Inc. RELM WIRELESS CORP. FCC ID: ARURPV516A Portable VHF PTT Radio Transceiver (150-174MHz) 11 CELLTECH RESEARCH INC. 1955 Moss Court, Kelowna B.C. Canada V1Y 9L3 Test Report S/N: 092601-169ARU Date of Tests: October 16, 2001 FCC SAR Evaluation _________________________________________________________________________________________________________ 17.0 REFERENCES (1) ANSI, ANSI/IEEE C95.1: IEEE Standard for Safety Levels with Respect to Human Exposure to Radio Frequency Electromagnetic Fields, 3kHz to 300 Ghz, The Institute of Electrical and Electronics Engineers, Inc., New York, NY: 1992. (2) Federal Communications Commission, “Evaluating Compliance with FCC Guidelines for Human Exposure to Radio frequency Electromagnetic Fields”, OET Bulletin 65, Supplement C (Edition 01-01), FCC, Washington, D.C. 20554: June 2001. (3) Thomas Schmid, Oliver Egger, and Neils Kuster, “Automated E-field scanning system for dosimetric assessments”, IEEE Transaction on Microwave Theory and Techniques, Vol. 44, pp. 105 – 113: January 1996. (4) Niels Kuster, Ralph Kastle, and Thomas Schmid, “Dosimetric evaluation of mobile communications equipment with know precision”, IEICE Transactions of Communications, vol. E80-B, no. 5, pp. 645 – 652: May 1997. © 2001 Celltech Research Inc. RELM WIRELESS CORP. FCC ID: ARURPV516A Portable VHF PTT Radio Transceiver (150-174MHz) 12 CELLTECH RESEARCH INC. Test Report S/N: 092601-169ARU Date of Tests: October 16, 2001 FCC SAR Evaluation 1955 Moss Court, Kelowna B.C. Canada V1Y 9L3 _________________________________________________________________________________________________________ APPENDIX A - SAR MEASUREMENT DATA © 2001 Celltech Research Inc. RELM WIRELESS CORP. FCC ID: ARURPV516A Portable VHF PTT Radio Transceiver (150-174MHz) 13 Celltech Research Inc. RELM Wireless Corporation FCC ID: ARURPV516A SAM Phantom; Flat Section; Position: (90°,90°) Probe: ET3DV6 - SN1590; ConvF(7.71,7.71,7.71); Crest factor: 1.0 150 MHz Brain : σ = 0.76 mho/m εr = 52.3 ρ = 1.00 g/cm3 Coarse: Dx = 20.0, Dy = 20.0, Dz = 10.0 Cube 4x4x7 SAR (1g): 0.374 mW/g, SAR (10g): 0.282 mW/g Face SAR at 2.5 cm Separation Distance Relm Wireless Model: RPV516A Continuous Wave Mode Low Channel (150.05 MHz) Conducted Power: 5.3 Watts Date Tested: October 16, 2001 SARTot [mW/g] 3.65E-1 3.09E-1 2.53E-1 1.97E-1 1.40E-1 8.42E-2 2.81E-2 Celltech Research Inc. Celltech Research Inc. RELM Wireless Corporation FCC ID: ARURPV516A SAM Phantom; Flat Section; Position: (90°,90°) Probe: ET3DV6 - SN1590; ConvF(7.71,7.71,7.71); Crest factor: 1.0 150 MHz Brain : σ = 0.76 mho/m εr = 52.3 ρ = 1.00 g/cm3 Coarse: Dx = 20.0, Dy = 20.0, Dz = 10.0 Cube 4x4x7 SAR (1g): 0.251 mW/g , SAR (10g): 0.187 mW/g Face SAR at 2.5 cm Separation Distance Relm Wireless Model: RPV516A Continuous Wave Mode Mid Channel (162.50 MHz) Conducted Power: 5.3 Watts Date Tested: October 16, 2001 SARTot [mW/g] 2.45E-1 2.07E-1 1.70E-1 1.32E-1 9.43E-2 5.66E-2 1.89E-2 Celltech Research Inc. Celltech Research Inc. RELM Wireless Corporation FCC ID: ARURPV516A SAM Phantom; Flat Section; Position: (90°,90°) Probe: ET3DV6 - SN1590; ConvF(7.71,7.71,7.71); Crest factor: 1.0 150 MHz Brain : σ = 0.76 mho/m εr = 52.3 ρ = 1.00 g/cm3 Coarse: Dx = 20.0, Dy = 20.0, Dz = 10.0 Cube 4x4x7 SAR (1g): 0.138 mW/g, SAR (10g): 0.104 mW/g Face SAR at 2.5 cm Separation Distance Relm Wireless Model: RPV516A Continuous Wave Mode High Channel (173.95 MHz) Conducted Power: 5.3 Watts Date Tested: October 16, 2001 SARTot [mW/g] 1.21E-1 1.02E-1 8.36E-2 6.50E-2 4.64E-2 2.79E-2 9.29E-3 Celltech Research Inc. 10/16/01 RELM Wireless Corporation FCC ID: ARURPV516A SAM Phantom; Flat Section Probe: ET3DV6 - SN1590; ConvF(7.71,7.71,7.71); Crest factor: 1.0 150 MHz Brain : σ = 0.76 mho/m εr = 52.3 ρ = 1.00 g/cm3 Cube 4x4x7 Z-Axis Extrapolation at Peak SAR Location Face SAR at 2.5 cm Separation Distance Relm Wireless Model: RPV516A Continuous Wave Mode Low Channel (150.05 MHz) Conducted Power: 5.3 Watts Date Tested: October 16, 2001 0.40 SAR tot [mW/g] 0.30 0.20 0.10 0.00 10 20 [mm] Celltech Research Inc. 30 40 Celltech Research Inc. RELM Wireless Corporation FCC ID: ARURPV516A SAM Phantom; Flat Section; Position: (270°,270°) Probe: ET3DV6 - SN1590; ConvF(7.65,7.65,7.65); Crest factor: 1.0 150 MHz Muscle: σ = 0.80 mho/m εr = 61.9 ρ = 1.00 g/cm3 Coarse: Dx = 20.0, Dy = 20.0, Dz = 10.0 Cube 4x4x7 SAR (1g): 0.965 mW/g, SAR (10g): 0.612 mW/g Body SAR with 1.4 cm Belt-Clip Separation Relm Wireless Model: RPV516A Continuous Wave Mode Low Channel (150.05 MHz) Conducted Power: 5.3 Watts Date Tested: October 16, 2001 SARTot [mW/g] 8.91E-1 7.54E-1 6.17E-1 4.80E-1 3.43E-1 2.06E-1 6.86E-2 Celltech Research Inc. Celltech Research Inc. RELM Wireless Corporation FCC ID: ARURPV516A SAM Phantom; Flat Section; Position: (270°,270°) Probe: ET3DV6 - SN1590; ConvF(7.65,7.65,7.65); Crest factor: 1.0 150 MHz Muscle: σ = 0.80 mho/m εr = 61.9 ρ = 1.00 g/cm3 Coarse: Dx = 20.0, Dy = 20.0, Dz = 10.0 Cube 4x4x7 SAR (1g): 0.645 mW/g, SAR (10g): 0.468 mW/g Body SAR with 1.4 cm Belt-Clip Separation Relm Wireless Model: RPV516A Continuous Wave Mode Mid Channel (162.50 MHz) Conducted Power: 5.3 Watts Date Tested: October 16, 2001 SARTot [mW/g] 6.36E-1 5.38E-1 4.40E-1 3.42E-1 2.45E-1 1.47E-1 4.89E-2 Celltech Research Inc. Celltech Research Inc. RELM Wireless Corporation FCC ID: ARURPV516A SAM Phantom; Flat Section; Position: (270°,270°) Probe: ET3DV6 - SN1590; ConvF(7.65,7.65,7.65); Crest factor: 1.0 150 MHz Muscle: σ = 0.80 mho/m εr = 61.9 ρ = 1.00 g/cm3 Coarse: Dx = 20.0, Dy = 20.0, Dz = 10.0 Cube 4x4x7 SAR (1g): 0.138 mW/g , SAR (10g): 0.103 mW/g Body SAR with 1.4 cm Belt-Clip Separation Relm Wireless Model: RPV516A Continuous Wave Mode High Channel (173.95 MHz) Conducted Power: 5.3 Watts Date Tested: October 16, 2001 SARTot [mW/g] 1.32E-1 1.12E-1 9.13E-2 7.10E-2 5.07E-2 3.04E-2 1.01E-2 Celltech Research Inc. 11/16/01 RELM Wireless Corporation FCC ID: ARURPV516A SAM Phantom; Flat Section Probe: ET3DV6 - SN1590; ConvF(7.65,7.65,7.65); Crest factor: 1.0; 150 MHz Muscle: σ = 0.80 mho/m εr = 61.9 ρ = 1.00 g/cm3 Cube 4x4x7 Z-Axis Extrapolation at Peak SAR Location Body SAR with 1.4 cm Belt-Clip Separation Relm Wireless Model: RPV516A Continuous Wave Mode Low Channel (150.05 MHz) Conducted Power: 5.3 Watts Date Tested: October 16, 2001 1.8 1.6 SAR tot [mW/g] 1.4 1.2 1.0 0.8 0.6 0.4 0.2 0.0 10 20 [mm] Celltech Research Inc. 30 40 CELLTECH RESEARCH INC. Test Report S/N: 092601-169ARU Date of Tests: October 16, 2001 FCC SAR Evaluation 1955 Moss Court, Kelowna B.C. Canada V1Y 9L3 _________________________________________________________________________________________________________ APPENDIX B - DIPOLE VALIDATION © 2001 Celltech Research Inc. RELM WIRELESS CORP. FCC ID: ARURPV516A Portable VHF PTT Radio Transceiver (150-174MHz) 14 Celltech Research Inc. Dipole 900 MHz SAM Phantom; Flat Section; - Validation Date: October 16, 2001 Probe: ET3DV6 - SN1590; ConvF(6.83,6.83,6.83); Crest factor: 1.0; Brain 900 MHz: σ = 0.97 mho/m εr = 42.4 ρ = 1.00 g/cm3 Cubes (2): Peak: 4.47 mW/g ± 0.00 dB, SAR (1g): 2.76 mW/g ± 0.00 dB, SAR (10g): 1.74 mW/g ± 0.00 dB, (Worst-case extrapolation) Penetration depth: 11.5 (10.4, 12.9) [mm] Powerdrift: -0.02 dB SARTot [mW/g] 2.96E+0 2.66E+0 2.36E+0 2.06E+0 1.77E+0 1.478E+0 1.17E+0 8.91E-1 5.93E-1 2.96E-1 Celltech Research Inc. 06/19/01 Validation Dipole D900V2 SN:054, d = 15 mm Frequency: 900 MHz; Antenna Input Power: 250 [mW] Generic Twin Phantom; Flat Section; Grid Spacing:Dx = 15.0, Dy = 15.0, Dz = 10.0 Probe: ET3DV6 - SN1507; ConvF(6.27,6.27,6.27); Crest factor: 1.0; IEEE1528 900 MHz: σ = 0.97 mho/m εr = 42.4 ρ = 1.00 g/cm 3 Cubes (2): Peak: 4.47 mW/g ± 0.05 dB, SAR (1g): 2.78 mW/g ± 0.04 dB, SAR (10g): 1.76 mW/g ± 0.02 dB, (Worst-case extrapolation) Penetration depth: 11.5 (10.3, 13.2) [mm] Powerdrift: -0.00 dB SARTot [mW/g] 2.50E+0 2.25E+0 2.00E+0 1.75E+0 1.50E+0 1.25E+0 1.00E+0 7.50E-1 5.00E-1 2.50E-1 Schmid & Partner Engineering AG, Zurich, Switzerland CELLTECH RESEARCH INC. Test Report S/N: 092601-169ARU Date of Tests: October 16, 2001 FCC SAR Evaluation 1955 Moss Court, Kelowna B.C. Canada V1Y 9L3 _________________________________________________________________________________________________________ APPENDIX C - PROBE CALIBRATION © 2001 Celltech Research Inc. RELM WIRELESS CORP. FCC ID: ARURPV516A Portable VHF PTT Radio Transceiver (150-174MHz) 15 Probe ET3DV6 SN:1590 Manufactured: Calibrated: March 19, 2001 March 26, 2001 Calibrated for System DASY3 Page 1 of 8 ET3DV6 SN:1590 DASY3 - Parameters of Probe: ET3DV6 SN:1590 Sensitivity in Free Space Diode Compression NormX 1.77 µV/(V/m) DCP X 100 mV NormY 1.91 µV/(V/m) DCP Y 100 mV NormZ 1.67 µV/(V/m) DCP Z 100 mV Sensitivity in Tissue Simulating Liquid Head ConvF X ConvF Y ConvF Z Head ConvF Y ConvF Z Head ConvF Y ConvF Z ConvF Y ConvF Z 0.29 2.72 Alpha Depth σ = 0.97 ± 10% mho/m 6.83 ± 7% (k=2) 6.83 ± 7% (k=2) 6.83 ± 7% (k=2) Boundary effect: 0.37 2.48 Alpha Depth σ = 1.23 ± 10% mho/m εr = 40.4 ± 5% 6.13 interpolated 6.13 interpolated 6.13 interpolated Boundary effect: 0.47 2.17 Alpha Depth σ = 1.40 ± 10% mho/m εr = 40 ± 5% 1800 MHz ConvF X Boundary effect: εr = 42 ± 5% 1500 MHz ConvF X Head 7.36 extrapolated 7.36 extrapolated 7.36 extrapolated 900 MHz ConvF X σ = 0.87 ± 10% mho/m εr = 43.5 ± 5% 450 MHz 5.78 ± 7% (k=2) 5.78 ± 7% (k=2) 5.78 ± 7% (k=2) Boundary effect: 0.53 2.01 Alpha Depth Sensor Offset Probe Tip to Sensor Center 2.7 mm Optical Surface Detection 1.2 ± 0.2 mm Page 2 of 8 ET3DV6 SN:1590 Receiving Pattern (φ) , θ = 0° f = 30 MHz, TEM cell ifi110 f = 100 MHz, TEM cell ifi110 340 350 10 20 330 340 30 320 350 10 20 330 40 30 320 310 50 300 40 310 60 290 50 300 70 60 290 70 280 80 280 80 270 90 270 90 260 100 260 100 250 110 240 250 120 230 130 220 110 240 120 230 140 210 130 220 150 200 190 170 140 210 160 150 200 190 180 Tot Tot f = 900 MHz, TEM cell ifi110 350 160 180 f = 300 MHz, TEM cell ifi110 340 170 10 20 330 340 30 320 350 10 20 330 40 30 320 310 50 300 40 310 60 290 70 280 50 300 60 290 70 80 280 270 90 270 90 260 100 260 100 250 110 240 120 230 130 220 140 210 80 250 110 240 120 230 130 220 150 200 190 170 140 210 160 150 200 190 180 170 160 180 Tot Page 3 of 8 Tot ET3DV6 SN:1590 f = 1800 MHz, WG R22 f = 2500 MHz, WG R26 340 350 10 20 330 340 30 320 350 10 20 330 40 30 320 310 50 300 40 310 60 290 70 280 50 300 60 290 70 80 280 270 90 270 90 260 100 260 100 250 110 240 120 230 80 250 130 220 120 230 140 210 110 240 130 220 150 200 190 170 140 210 160 150 200 190 180 170 160 180 Tot Tot Isotropy Error (φ), θ = 0° 1.00 0.80 error[dB] 0.60 0.40 0.20 30 MHz 0.00 300 MHz -0.20 -0.40 900 MHz -0.60 2500 MHz 100 MHz 1800 MHz -0.80 -1.00 60 120 180 Page 4 of 8 240 300 360 ET3DV6 SN:1590 Frequency Response of E-Field ( TEM-Cell:ifi110, Waveguide R22) 1.50 1.40 1.30 frequency response 1.20 1.10 1.00 0.90 0.80 0.70 0.60 0.50 500 1000 1500 2000 f [MHz] TEM Page 5 of 8 R22 2500 3000 ET3DV6 SN:1590 Dynamic Range f(SARbrain) ( TEM-Cell:ifi110 ) 1.E+7 1.E+6 1.E+5 µV 1.E+4 1.E+3 1.E+2 1.E+1 1.E+0 0.0001 0.001 0.01 0.1 1. 10. 100. mW/cm3 not compensated compensated errror[dB] 1.0 0.0 -1.0 -2.0 0.001 0.01 0.1 mW/cm3 ET3DV6 SN:1590 Page 6 of 8 10 100 Conversion Factor Assessment f = 900 MHz, WG R9 (head) f = 1800 MHz, WG R22 (head) 0.90 7.00 0.80 6.00 SAR[mW/cm 3] / W SAR[mW/cm 3] / W 0.70 0.60 0.50 0.40 0.30 5.00 4.00 3.00 2.00 0.20 1.00 0.10 0.00 0.00 20 40 60 20 z[mm] Analytical Head Head 900 MHz 40 z[mm] Measuremets Analytical εr = 42 ± 5% Measuremets σ = 0.97 ± 10% mho/m ConvF X 6.83 ± 7% (k=2) Boundary effect: ConvF Y 6.83 ± 7% (k=2) Alpha 0.37 ConvF Z 6.83 ± 7% (k=2) Depth 2.48 1800 MHz εr = 40 ± 5% σ = 1.40 ± 10% mho/m ConvF X 5.78 ± 7% (k=2) Boundary effect: ConvF Y 5.78 ± 7% (k=2) Alpha 0.53 ConvF Z 5.78 ± 7% (k=2) Depth 2.01 ET3DV6 SN:1590 Page 7 of 8 60 Deviation from Isotropy in HSL Error (θ,φ ), f = 900 MHz 1.00 0.80 0.60 40 0.20 80 0.00 120 -0.20 160 θ -0.40 -0.60 -0.80 -1.00 200 240 280 320 10 20 30 40 50 60 φ -1.00--0.80 -0.80--0.60 -0.60--0.40 -0.40--0.20 -0.20-0.00 0.00-0.20 0.20-0.40 0.40-0.60 0.60-0.80 0.80-1.00 Page 8 of 8 Error [dB] 0.40 CELLTECH RESEARCH INC. 1955 Moss Court, Kelowna B.C. Canada V1Y 9L3 Test Report S/N: 092601-169ARU Date of Tests: October 16, 2001 FCC SAR Evaluation _________________________________________________________________________________________________________ APPENDIX D - DETERMINATION OF E-FIELD PROBE CONVERSION NUMBERS © 2001 Celltech Research Inc. RELM WIRELESS CORP. FCC ID: ARURPV516A Portable VHF PTT Radio Transceiver (150-174MHz) 16 Determination of Probe Conversion Factors for 150MHz Since at this time there exists no experimental method in determining E-field probe conversion factors for frequencies below 800MHz, the following procedure was carried out to give an approximation of the probe conversion factors for 150MHz. The accuracy of the system was determined based on the two calibrated test frequencies of 900 and 1800MHz, using validation dipoles as supplied by the manufacturer. The measured results were found to be within the specified tolerances. For conversion factors outside these two frequencies a linear extrapolation was performed as per the manufacturer’s recommendations. In order to determine the accuracy of the conversion factors, 300 and 450MHz dipoles were constructed in accordance with IEEE Std. P1528. The two dipoles were then characterized for SAR using the appropriate head simulating fluid for the given frequencies in a planar phantom as prescribed in IEEE Std. P1528. The table below indicates the analytical target values for each dipole with the associated measured results. Frequency (MHz) Analytical SAR @ 1W input averaged over 1 gram Measured SAR @ 1W input averaged over 1 gram Delta ∆ 300 3.0 3.51 17.0% 450 4.9 5.77 17.8% Fluid Parameters εr=45.3 σ=0.87 εr=43.5 σ=0.87 The extrapolated head conversion factors determined for 300 and 450MHz resulted in SAR values being 17.0% and 17.8% greater than expected for each frequency respectively. It is assumed that as this extrapolation is extended down to 150MHz, the resulting SAR will again be overestimated by at least 17%. The body conversion factors were determined based on a combination of the obtained data from the validations, and numerical modeling results from an identical probe from the same manufacturer. The following two pages show examples of the conversion factors that were derived through numerical modeling for a probe of similar properties. Dosimetric E-Field Probe ET3DV6 EXAMPLE Head Tissue Conversion Factor (+ standard deviation) 400 MHz ConvF 7.64 + 8% εr = 44.4 σ = 0.87 mho/m CENELEC Head Tissue 835 MHz ConvF 6.54 + 8% εr = 42.5 σ = 0.98 mho/m CENELEC Head Tissue 900 MHz ConvF 6.41 + 8% εr = 42.3 σ = 0.99 mho/m CENELEC Head Tissue 350 MHz ConvF 7.76 + 8% εr = 44.7 σ = 0.87 mho/m IEEE Head Tissue 7.52 + 8% εr = 43.5 σ = 0.87 mho/m IEEE Head Tissue 6.53 + 8% εr = 41.5 σ = 0.90 mho/m IEEE Head Tissue 450 MHz 835 MHz 925 MHz 1500 MHz 1900 MHz 2450 MHz 2450 MHz ConvF ConvF ConvF ConvF ConvF ConvF ConvF 6.37 + 8% 6.04 + 8% 5.41 + 8% 5.18 + 8% 5.40 + 8% εr = 41.45 σ = 0.98 mho/m IEEE Head Tissue εr = 40.43 σ = 1.23 mho/m IEEE Head Tissue εr = 40.0 σ = 1.40 mho/m IEEE Head Tissue εr = 39.2 σ = 1.8 mho/m IEEE Head Tissue εr = 37.2 σ = 2.09 mho/m H1800 at 2450 MHz Dosimetric E-Field Probe ET3DV6 EXAMPLE Body Tissue Conversion Factor (+ standard deviation) 35 MHz ConvF 8.77 + 15% εr = 85.19 σ = 0.69 mho/m FCC Body Tissue 75 MHz ConvF 8.68 + 10% εr = 69.93 σ = 0.72 mho/m FCC Body Tissue 150 MHz ConvF 8.51 + 8% εr = 62.68 σ = 0.75 mho/m FCC Body Tissue 350 MHz ConvF 7.64 + 8% εr = 58.41 σ = 0.80 mho/m FCC Body Tissue 7.40 + 8% εr = 57.62 σ = 0.83 mho/m FCC Body Tissue 6.38 + 8% εr = 56.25 σ = 0.93 mho/m FCC Body Tissue 450 MHz 784 MHz 835 MHz 925 MHz 1500 MHz 1900 MHz 2450 MHz ConvF ConvF ConvF ConvF ConvF ConvF ConvF 6.28 + 8% 6.10 + 8% 5.44 + 8% εr = 56.11 σ = 0.95 mho/m FCC Body Tissue εr = 55.9 σ = 0.98 mho/m FCC Body Tissue εr = 54.87 σ = 1.23 mho/m FCC Body Tissue 4.82 + 8% εr = 54.3 σ = 1.45 mho/m FCC Body Tissue 4.53 + 8% εr = 53.57 σ = 1.81 mho/m FCC Body Tissue Body Conversion Factor a given Frequency 10 Conversion Factor 500 1000 1500 2000 2500 3000 Frequency (MHz) Head and Body Conversion Factors Conversion Factor Head CF Body CF 500 1000 1500 2000 Frequency (MHz) 2500 3000 Frequency Head Conversion Factors Body Conversion Factors Delta ∆ 450 7.52 7.40 1.62 835 6.53 6.28 3.98 925 6.37 6.10 4.43 1500 6.04 5.44 11.02 1900 5.41 4.82 12.24 2450 5.18 4.53 14.35 Conclusion: Based on the results from the 300 and 450MHz validations, the derived conversion factors should over-estimate the SAR for a device operating in the 150MHz band by approximately 17%. In addition, the above graphs and tabular results show that the probe conversion factors vary only slightly between head and body as the frequency approaches 450MHz. It is therefore safe to assume that as the frequency is further extended to 150MHz, the difference in the conversion factors between head and body will be less significant. Therefore, for this reason only one conversion factor is reported for both head and body at 150MHz. CELLTECH RESEARCH INC. Test Report S/N: 092601-169ARU Date of Tests: October 16, 2001 FCC SAR Evaluation 1955 Moss Court, Kelowna B.C. Canada V1Y 9L3 _________________________________________________________________________________________________________ APPENDIX E - SAR SENSITIVITIES © 2001 Celltech Research Inc. RELM WIRELESS CORP. FCC ID: ARURPV516A Portable VHF PTT Radio Transceiver (150-174MHz) 17 Application Note: SAR Sensitivities Application Note: SAR Sensitivities Introduction The measured SAR-values in homogeneous phantoms depend strongly on the electrical parameters of the liquid. Liquids with exactly matching parameters are difficult to produce; there is always a small error involved in the production or measurement of the liquid parameters. The following sensitivities allow the estimation of the influence of small parameter errors on the measured SAR values. The calculations are based on an approximation formula [1] for the SAR of an electrical dipole near the phantom surface and a adapted plane wave approximation for the penetration depth. The sensitivities are given in percent SAR change per percent change in the controlling parameter: d SAR / SAR S(x) = ——————— dx/x The controlling parameters x are: • ε : permitivity • σ : conductivity • ρ : brain density (= one over integration volume) For example: If The liquid permitivity increases by 2 percent and the sensitivity of the SAR to permitivity is -0.6 then the SAR will decrease by 1.2 percent. The sensitivities are given for surface SAR values and averaged SAR values for 1 g and 10 g cubes and for dipole distances d of 10mm (for frequencies below 1000 MHz) and 15mm (for frequencies above 1000 MHz) from the liquid surface. Liquid parameters are as proposed in the new standards (e.g., IEEE 1528). References [1] N. Kuster and Q. Balzano, “Energy absorption mechanism by biological bodies in the near field of dipole antennas above 300 MHz”, IEEE Transacions on Vehicular Technology, vol. 41(1), pp. 17-23, 1992. Schmid & Partner Engineering AG, Zurich, Switzerland Application Note: SAR Sensitivities ε Parameter σ ρ f=300 MHz (εr=45.3, σ =0.87S/m, ρ=1g/cm 3 ) d=15mm: Surface 1 g 10 g f=450 MHz (εr=43.5, σ =0.87S/m, ρ=1g/cm 3 ) - 0.41 - 0.33 - 0.26 + 0.48 + 0.28 + 0.09 — 0.08 0.16 d=15mm: - 0.56 - 0.46 - 0.37 + 0.67 + 0.43 + 0.22 — 0.09 0.17 - 0.70 - 0.57 - 0.45 + 0.86 + 0.59 + 0.35 — 0.10 0.18 - 0.69 - 0.55 - 0.44 + 0.86 + 0.57 + 0.32 — 0.10 0.19 - 0.73 - 0.55 - 0.42 + 0.91 + 0.55 + 0.27 — 0.12 0.22 - 0.73 - 0.52 - 0.38 + 0.92 + 0.51 + 0.21 — 0.14 0.24 - 0.73 - 0.53 - 0.39 + 0.93 + 0.51 + 0.22 — 0.14 0.24 - 0.74 - 0.53 - 0.39 + 0.94 + 0.52 + 0.22 — 0.14 0.24 - 0.74 - 0.49 - 0.34 + 0.93 + 0.41 + 0.12 — 0.17 0.28 - 0.75 - 0.45 - 0.32 + 0.90 + 0.28 + 0.02 — 0.21 0.31 Surface 1 g 10 g f=835 MHz (εr=41.5, σ =0.90S/m, ρ=1g/cm 3 ) d=15mm: Surface 1 g 10 g f=900 MHz (εr=41.5, σ =0.97S/m, ρ=1g/cm 3 ) d=15mm: Surface 1 g 10 g f=1450 MHz (εr=40.5, σ =1.20/m, ρ=1g/cm 3 ) d=10mm: Surface 1 g 10 g f=1800 MHz (εr=40.0, σ =1.40S/m, ρ=1g/cm 3 ) d=10mm: Surface 1 g 10 g f=1900 MHz (εr=40.0, σ =1.40S/m, ρ=1g/cm 3 ) d=10mm: Surface 1 g 10 g f=2000 MHz (εr=40.0, σ =1.40S/m, ρ=1g/cm 3 ) d=10mm: Surface 1 g 10 g f=2450 MHz (εr=39.2, σ =1.80S/m, ρ=1g/cm 3 ) d=10mm: Surface 1 g 10 g f=3000 MHz (εr=38.5, σ =2.40S/m, ρ=1g/cm 3 ) d=10mm: Surface 1 g 10 g Schmid & Partner Engineering AG, Zurich, Switzerland CELLTECH RESEARCH INC. Test Report S/N: 092601-169ARU Date of Tests: October 16, 2001 FCC SAR Evaluation 1955 Moss Court, Kelowna B.C. Canada V1Y 9L3 _________________________________________________________________________________________________________ APPENDIX F - SAR TEST SETUP PHOTOGRAPHS © 2001 Celltech Research Inc. RELM WIRELESS CORP. FCC ID: ARURPV516A Portable VHF PTT Radio Transceiver (150-174MHz) 18 CELLTECH RESEARCH INC. Test Report S/N: 092601-169ARU Date of Tests: October 16, 2001 FCC SAR Evaluation 1955 Moss Court, Kelowna B.C. Canada V1Y 9L3 _________________________________________________________________________________________________________ FACE-HELD SAR TEST SETUP PHOTOGRAPHS 2.5cm Separation Distance 2.5 cm © 2001 Celltech Research Inc. RELM WIRELESS CORP. FCC ID: ARURPV516A Portable VHF PTT Radio Transceiver (150-174MHz) CELLTECH RESEARCH INC. Test Report S/N: 092601-169ARU Date of Tests: October 16, 2001 FCC SAR Evaluation 1955 Moss Court, Kelowna B.C. Canada V1Y 9L3 _________________________________________________________________________________________________________ BODY-WORN SAR TEST SETUP PHOTOGRAPHS with 1.4cm Belt-Clip 1.4 cm © 2001 Celltech Research Inc. RELM WIRELESS CORP. FCC ID: ARURPV516A Portable VHF PTT Radio Transceiver (150-174MHz)
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.4 Linearized : No Creator : Microsoft Word Create Date : 2001:12:19 15:47:16 Title : RPV516A SAR Test Report revised 121901.doc Author : Jonathan Producer : Acrobat PDFWriter 5.0 for Windows Modify Date : 2001:12:19 17:12:22-08:00 Page Count : 47EXIF Metadata provided by EXIF.tools